Sample records for smallest real difference

  1. Test-Retest Reliability of the Self-Reported Impairments in Persons With Late Effects of Polio (SIPP) Rating Scale.

    PubMed

    Brogårdh, Christina; Lexell, Jan

    2016-05-01

    A new 13-item rating scale, the Self-Reported Impairments in Persons with Late Effects of Polio (SIPP), has been developed. The SIPP has been analyzed using the Rasch method and has shown good construct validity and internal consistency. To establish its clinical utility, further evaluation of its psychometric properties is needed. To evaluate the test-retest reliability of the SIPP and to define limits for the smallest change that indicates a real change, both for a group of persons and a single individual. A postal survey. University Hospital. Fifty-one persons (31 men and 20 women; mean age, 72 years) with clinically verified late effects of polio. Not applicable. The participants completed the SIPP twice, 2 weeks apart. The response frequencies at test occasion 1 (T1) and test occasion 2 (T2) were calculated. Test-retest reliability was analyzed using the percentage agreement of each item, the intraclass correlation coefficient, and the mean difference between the test occasions (đ), together with the 95% confidence intervals for đ, the standard error of measurement, the smallest real difference, and a Bland-Altman plot. The percentage agreement (ie, the same scoring at both test occasions) was >70% for 10 of 13 items. The mean score (standard deviation) was 27.9 (5.7) points at T1 and 28.2 (6.0) points at T2, with no systematic difference between the test occasions. The intraclass correlation coefficient was 0.88, the standard error of measurement (the smallest change for a group of persons) was 2.0 points, and the smallest real difference (the smallest change for a single individual) was 5.6 points, respectively. The SIPP is a reliable rating scale in persons with late effects of polio and can be used to evaluate effects of rehabilitation interventions and changes of perceived impairments over time both for a group of persons and for a single individual. Copyright © 2016 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  2. Reliability and smallest real difference of the ankle lunge test post ankle fracture.

    PubMed

    Simondson, David; Brock, Kim; Cotton, Susan

    2012-02-01

    This study aimed to determine the reliability and the smallest real difference of the Ankle Lunge test in an ankle fracture patient population. In the post immobilisation stage of ankle fracture, ankle dorsiflexion is an important measure of progress and outcome. The Ankle Lunge test measures weight bearing dorsiflexion, resulting in negative scores (knee to wall distance) and positive scores (toe to wall distance), for which the latter has proven reliability in normal subjects only. A consecutive sample of ankle fracture patients with permission to commence weight bearing, were recruited to the study. Three measurements of the Ankle Lunge Test were performed each by two raters, one senior and one junior physiotherapist. These occurred prior to therapy sessions in the second week after plaster removal. A standardised testing station was utilised and allowed for both knee to wall distance and toe to wall distance measurement. Data was collected from 10 individuals with ankle fracture, with an average age of 36 years (SD 14.8). Seventy seven percent of observations were negative. Intra and inter-rater reliability yielded intra class correlations at or above 0.97, p < .001. There was a significant systematic bias towards improved scores during repeated measurement for one rater (p = .01). The smallest real difference was calculated as 13.8mm. The Ankle Lunge test is a practical and reliable tool for measuring weightbearing dorsiflexion post ankle fracture. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. Relative and absolute reliability of the clinical version of the Narrow Path Walking Test (NPWT) under single and dual task conditions.

    PubMed

    Gimmon, Yoav; Jacob, Grinshpon; Lenoble-Hoskovec, Constanze; Büla, Christophe; Melzer, Itshak

    2013-01-01

    Decline in gait stability has been associated with increased fall risk in older adults. Reliable and clinically feasible methods of gait instability assessment are needed. This study evaluated the relative and absolute reliability and concurrent validity of the testing procedure of the clinical version of the Narrow Path Walking Test (NPWT) under single task (ST) and dual task (DT) conditions. Thirty independent community-dwelling older adults (65-87 years) were tested twice. Participants were instructed to walk within the 6-m narrow path without stepping out. Trial time, number of steps, trial velocity, number of step errors, and number of cognitive task errors were determined. Intraclass correlation coefficients (ICCs) were calculated as indices of agreement, and a graphic approach called "mountain plot" was applied to help interpret the direction and magnitude of disagreements between testing procedures. Smallest detectable change and smallest real difference (SRD) were computed to determine clinically relevant improvement at group and individual levels, respectively. Concurrent validity was assessed using Performance Oriented Mobility Assessment Tool (POMA) and the Short Physical Performance Battery (SPPB). Test-retest agreement (ICC1,2) varied from 0.77 to 0.92 in ST and from 0.78 to 0.92 in DT conditions, with no apparent systematic differences between testing procedures demonstrated by the mountain plot graphs. Smallest detectable change and smallest real change were small for motor task performance and larger for cognitive errors. Significant correlations were observed for trial velocity and trial time with POMA and SPPB. The present results indicate that the NPWT testing procedure is highly reliable and reproducible. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  4. Test-retest reliability, smallest real difference and concurrent validity of six different balance tests on young people with mild to moderate intellectual disability.

    PubMed

    Blomqvist, Sven; Wester, Anita; Sundelin, Gunnevi; Rehn, Börje

    2012-12-01

    Some studies have reported that people with intellectual disability may have reduced balance ability compared with the population in general. However, none of these studies involved adolescents, and the reliability and validity of balance tests in this population are not known. The purpose of this study was to examine the reliability of six different balance tests and to investigate their concurrent validity. Test-retest reliability assessment. All subjects were recruited from a special school for people with intellectual disability in Bollnäs, Sweden. Eighty-nine adolescents (35 females and 54 males) with mild to moderate intellectual disability with a mean age of 18 years (range 16 to 20 years). All subjects followed the same test protocol on two occasions within an 11-day period. Balance test performances. Intraclass correlation coefficients greater than 0.80 were achieved for four of the balance tests: Extended Timed Up and Go Test, Modified Functional Reach Test, One-leg Stance Test and Force Platform Test. The smallest real differences ranged from 12% to 40%; less than 20% is considered to be low. Concurrent validity among these balance tests varied between no and low correlation. The results indicate that these tests could be used to evaluate changes in balance ability over time in people with mild to moderate intellectual disability. The low concurrent validity illustrates the importance of knowing more about the influence of various sensory subsystems that are significant for balance among adolescents with intellectual disability. Copyright © 2011 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  5. Minimal invasive epicardial lead implantation: optimizing cardiac resynchronization with a new mapping device for epicardial lead placement.

    PubMed

    Maessen, J G; Phelps, B; Dekker, A L A J; Dijkman, B

    2004-05-01

    To optimize resynchronization in biventricular pacing with epicardial leads, mapping to determine the best pacing site, is a prerequisite. A port access surgical mapping technique was developed that allowed multiple pace site selection and reproducible lead evaluation and implantation. Pressure-volume loops analysis was used for real time guidance in targeting epicardial lead placement. Even the smallest changes in lead position revealed significantly different functional results. Optimizing the pacing site with this technique allowed functional improvement up to 40% versus random pace site selection.

  6. Equivalence of partition properties and determinacy

    PubMed Central

    Kechris, Alexander S.; Woodin, W. Hugh

    1983-01-01

    It is shown that, within L(ℝ), the smallest inner model of set theory containing the reals, the axiom of determinacy is equivalent to the existence of arbitrarily large cardinals below Θ with the strong partition property κ → (κ)κ. PMID:16593299

  7. The ultimate picture-the combination of live cell superresolution microscopy and single molecule tracking yields highest spatio-temporal resolution.

    PubMed

    Dersch, Simon; Graumann, Peter L

    2018-06-01

    We are witnessing a breathtaking development in light (fluorescence) microscopy, where structures can be resolved down to the size of a ribosome within cells. This has already yielded surprising insight into the subcellular structure of cells, including the smallest cells, bacteria. Moreover, it has become possible to visualize and track single fluorescent protein fusions in real time, and quantify molecule numbers within individual cells. Combined, super resolution and single molecule tracking are pushing the limits of our understanding of the spatio-temporal organization even of the smallest cells to an unprecedented depth. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Smallest chimera states

    NASA Astrophysics Data System (ADS)

    Maistrenko, Yuri; Brezetsky, Serhiy; Jaros, Patrycja; Levchenko, Roman; Kapitaniak, Tomasz

    2017-01-01

    We demonstrate that chimera behavior can be observed in small networks consisting of three identical oscillators, with mutual all-to-all coupling. Three different types of chimeras, characterized by the coexistence of two coherent oscillators and one incoherent oscillator (i.e., rotating with another frequency) have been identified, where the oscillators show periodic (two types) and chaotic (one type) behaviors. Typical bifurcations at the transitions from full synchronization to chimera states and between different types of chimeras have been described. Parameter regions for the chimera states are obtained in the form of Arnold tongues, issued from a singular parameter point. Our analysis suggests that chimera states can be observed in small networks relevant to various real-world systems.

  9. Intra-rater Reliability of Arm and Hand Muscle Strength Measurements in Persons With Late Effects of Polio.

    PubMed

    Brogårdh, Christina; Flansbjer, Ulla-Britt; Carlsson, Håkan; Lexell, Jan

    2015-10-01

    Muscle weakness in the upper limb is common in persons with late effects of polio. To be able to measure muscle strength and follow changes over time, reliable measurements are needed. To evaluate the intra-rater reliability of isometric and isokinetic arm and hand muscle strength measurements in persons with late effects of polio. A test-retest design. A university hospital outpatient clinic. Twenty-eight persons (mean age 68 years, SD 11 years) with late effects of polio in their upper limbs. Isometric shoulder abduction, isokinetic concentric elbow flexion and extension, isometric elbow flexion, and isometric grip strength were measured twice, 14 days apart. Reliability was evaluated with the intra-class correlation coefficient, the mean difference between the test sessions (d¯), together with the 95% confidence intervals for d¯ , the standard error of measurement (SEM and SEM%), the smallest real difference (SRD and SRD%), and Bland-Altman graphs. A fixed dynamometer (Biodex) was used to measure arm strength and an electronic dynamometer (GRIP-it) was used to measure grip strength. Intra-rater reliability was high, with intra-class correlation coefficients between 0.87 and 0.98. The SEM%, representing the smallest change for a group of persons, ranged from 7%-24% for all strength measurements, and the SRD%, representing the smallest change for an individual person, ranged from 20%-67%. Muscle strength in the upper limbs can be reliably measured in persons with late effects of polio. However, the measurement errors indicate that the method is more suitable to detect changes in muscle strength for a group of persons than for an individual person. Copyright © 2015 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  10. Sunspot Cycle 24: Smallest Cycle in 100 Years?

    DTIC Science & Technology

    2005-01-11

    and power systems Wilcox Solar Observatories (WSO [Svalgaard et al., [National Oceanic and Atmospheric Administration, 2004; 1978], since 1976). The...are _W taken to be a measure of how well the procedure works (the oun* Wilson Solor Obs. Wico ,*Uf ts,. only real measure as far as we are concerned

  11. Evaluation and analysis of real-time precise orbits and clocks products from different IGS analysis centers

    NASA Astrophysics Data System (ADS)

    Zhang, Liang; Yang, Hongzhou; Gao, Yang; Yao, Yibin; Xu, Chaoqian

    2018-06-01

    To meet the increasing demands from the real-time Precise Point Positioning (PPP) users, the real-time satellite orbit and clock products are generated by different International GNSS Service (IGS) real-time analysis centers and can be publicly received through the Internet. Based on different data sources and processing strategies, the real-time products from different analysis centers therefore differ in availability and accuracy. The main objective of this paper is to evaluate availability and accuracy of different real-time products and their effects on real-time PPP. A total of nine commonly used Real-Time Service (RTS) products, namely IGS01, IGS03, CLK01, CLK15, CLK22, CLK52, CLK70, CLK81 and CLK90, will be evaluated in this paper. Because not all RTS products support multi-GNSS, only GPS products are analyzed in this paper. Firstly, the availability of all RTS products is analyzed in two levels. The first level is the epoch availability, indicating whether there is outage for that epoch. The second level is the satellite availability, which defines the available satellite number for each epoch. Then the accuracy of different RTS products is investigated on nominal accuracy and the accuracy degradation over time. Results show that Root-Mean-Square Error (RMSE) of satellite orbit ranges from 3.8 cm to 7.5 cm for different RTS products. While the mean Standard Deviations of Errors (STDE) of satellite clocks range from 1.9 cm to 5.6 cm. The modified Signal In Space Range Error (SISRE) for all products are from 1.3 cm to 5.5 cm for different RTS products. The accuracy degradation of the orbit has the linear trend for all RTS products and the satellite clock degradation depends on the satellite clock types. The Rb clocks on board of GPS IIF satellites have the smallest degradation rate of less than 3 cm over 10 min while the Cs clocks on board of GPS IIF have the largest degradation rate of more than 10 cm over 10 min. Finally, the real-time kinematic PPP is carried out to investigate the effects of different real-time products. The CLK90 has the best performance and mean RMSE of 26 globally distributed IGS stations in three components are 3.2 cm, 6.6 cm and 8.5 cm. And the second-best positioning results are using IGS03 products.

  12. How to test validity in orthodontic research: a mixed dentition analysis example.

    PubMed

    Donatelli, Richard E; Lee, Shin-Jae

    2015-02-01

    The data used to test the validity of a prediction method should be different from the data used to generate the prediction model. In this study, we explored whether an independent data set is mandatory for testing the validity of a new prediction method and how validity can be tested without independent new data. Several validation methods were compared in an example using the data from a mixed dentition analysis with a regression model. The validation errors of real mixed dentition analysis data and simulation data were analyzed for increasingly large data sets. The validation results of both the real and the simulation studies demonstrated that the leave-1-out cross-validation method had the smallest errors. The largest errors occurred in the traditional simple validation method. The differences between the validation methods diminished as the sample size increased. The leave-1-out cross-validation method seems to be an optimal validation method for improving the prediction accuracy in a data set with limited sample sizes. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  13. Energy compensation in the real world: good compensation for small portions of chocolate and biscuits over short time periods in complicit consumers using commercially available foods.

    PubMed

    Appleton, Katherine M; McKeown, Pascal P; Woodside, Jayne V

    2015-02-01

    While investigations using covert food manipulations tend to suggest that individuals are poor at adjusting for previous energy intake, in the real world adults rarely consume foods of which they are ill-informed. This study investigated the impact in fully complicit consumers of consuming commercially available dark chocolate, milk chocolate, sweet biscuits and fruit bars on subsequent appetite. Using a repeated measures design, participants received four small portions (4 × 10-11 g) of either dark chocolate, milk chocolate, sweet biscuits, fruit bars or no food throughout five separate study days (counterbalanced in order), and test meal intake, hunger, liking and acceptability were measured. Participants consumed significantly less at lunch following dark chocolate, milk chocolate and sweet biscuits compared to no food (smallest t(19) = 2.47, p = 0.02), demonstrating very good energy compensation (269-334%). No effects were found for fruit bars (t(19) = 1.76, p = 0.09), in evening meal intakes (F(4,72) = 0.62, p = 0.65) or in total intake (lunch + evening meal + food portions) (F(4,72) = 0.40, p = 0.69). No differences between conditions were found in measures of hunger (largest F(4,76) = 1.26, p = 0.29), but fruit bars were significantly less familiar than all other foods (smallest t(19) = 3.14, p = 0.01). These findings demonstrate good compensation over the short term for small portions of familiar foods in complicit consumers. Findings are most plausibly explained as a result of participant awareness and cognitions, although the nature of these cognitions cannot be discerned from this study. These findings however, also suggest that covert manipulations may have limited transfer to real world scenarios. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Assessment of disintegrant efficacy with fractal dimensions from real-time MRI.

    PubMed

    Quodbach, Julian; Moussavi, Amir; Tammer, Roland; Frahm, Jens; Kleinebudde, Peter

    2014-11-20

    An efficient disintegrant is capable of breaking up a tablet in the smallest possible particles in the shortest time. Until now, comparative data on the efficacy of different disintegrants is based on dissolution studies or the disintegration time. Extending these approaches, this study introduces a method, which defines the evolution of fractal dimensions of tablets as surrogate parameter for the available surface area. Fractal dimensions are a measure for the tortuosity of a line, in this case the upper surface of a disintegrating tablet. High-resolution real-time MRI was used to record videos of disintegrating tablets. The acquired video images were processed to depict the upper surface of the tablets and a box-counting algorithm was used to estimate the fractal dimensions. The influence of six different disintegrants, of different relative tablet density, and increasing disintegrant concentration was investigated to evaluate the performance of the novel method. Changing relative densities hardly affect the progression of fractal dimensions, whereas an increase in disintegrant concentration causes increasing fractal dimensions during disintegration, which are also reached quicker. Different disintegrants display only minor differences in the maximal fractal dimension, yet the kinetic in which the maximum is reached allows a differentiation and classification of disintegrants. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Small is beautiful: features of the smallest insects and limits to miniaturization.

    PubMed

    Polilov, Alexey A

    2015-01-07

    Miniaturization leads to considerable reorganization of structures in insects, affecting almost all organs and tissues. In the smallest insects, comparable in size to unicellular organisms, modifications arise not only at the level of organs, but also at the cellular level. Miniaturization is accompanied by allometric changes in many organ systems. The consequences of miniaturization displayed by different insect taxa include both common and unique changes. Because the smallest insects are among the smallest metazoans and have the most complex organization among organisms of the same size, their peculiar structural features and the factors that limit their miniaturization are of considerable theoretical interest to general biology.

  16. Vibration compensation for high speed scanning tunneling microscopy

    NASA Astrophysics Data System (ADS)

    Croft, D.; Devasia, S.

    1999-12-01

    Low scanning speed is a fundamental limitation of scanning tunneling microscopes (STMs), making real time imaging of surface processes and nanofabrication impractical. The effective scanning bandwidth is currently limited by the smallest resonant vibrational frequency of the piezobased positioning system (i.e., scanner) used in the STM. Due to this limitation, the acquired images are distorted during high speed operations. In practice, the achievable scan rates are much less than 1/10th of the resonant vibrational frequency of the STM scanner. To alleviate the scanning speed limitation, this article describes an inversion-based approach that compensates for the structural vibrations in the scanner and thus, allows STM imaging at high scanning speeds (relative to the smallest resonant vibrational frequency). Experimental results are presented to show the increase in scanning speeds achievable by applying the vibration compensation methods.

  17. Effects of body-mapping-designed clothing on heat stress and running performance in a hot environment.

    PubMed

    Jiao, Jiao; Li, Yi; Yao, Lei; Chen, Yajun; Guo, Yueping; Wong, Stephen H S; Ng, Frency S F; Hu, Junyan

    2017-10-01

    To investigate clothing-induced differences in human thermal response and running performance, eight male athletes participated in a repeated-measure study by wearing three sets of clothing (CloA, CloB, and CloC). CloA and CloB were body-mapping-designed with 11% and 7% increased capacity of heat dissipation respectively than CloC, the commonly used running clothing. The experiments were conducted by using steady-state running followed by an all-out performance running in a controlled hot environment. Participants' thermal responses such as core temperature (T c ), mean skin temperature ([Formula: see text]), heat storage (S), and the performance running time were measured. CloA resulted in shorter performance time than CloC (323.1 ± 10.4 s vs. 353.6 ± 13.2 s, p = 0.01), and induced the lowest [Formula: see text], smallest ΔT c , and smallest S in the resting and running phases. This study indicated that clothing made with different heat dissipation capacities affects athlete thermal responses and running performance in a hot environment. Practitioner Summary: A protocol that simulated the real situation in running competitions was used to investigate the effects of body-mapping-designed clothing on athletes' thermal responses and running performance. The findings confirmed the effects of optimised clothing with body-mapping design and advanced fabrics, and ensured the practical advantage of developed clothing on exercise performance.

  18. Real-life setting in data collection. The role of nutrition knowledge whilst selecting food products for weight management purposes in a supermarket environment.

    PubMed

    Saarela, Anna-Maria; Lapveteläinen, Anja T; Mykkänen, Hannu M; Kantanen, Teuvo T; Rissanen, Riitta L

    2013-12-01

    The aim was to explore the role of consumers' nutrition knowledge while selecting foods for weight management and the predominating food selection factors by combining quantitative and qualitative methodology in a real-life setting during two consecutive shopping tasks given in a supermarket. Thirty-six consumers were given a list of 11 products and asked to think-aloud while selecting (i) a product they usually buy and (ii) a product they use for weight management. After the consecutive shopping tasks, the subjects were interviewed and asked to answer a nutrition knowledge questionnaire. The subjects were categorized by the difference in the energy contents of their selections and the food selection criteria. The energy contents of the selections for weight management were reduced by 10-46%. Ten subjects with the greatest difference between the energy contents of their selections had higher level in nutrition knowledge and mentioned less nutritional issues during the selections than ten subjects with the smallest such differences. Taste was an important product selection criterion by the former group, while the latter focused primarily on price. Nutrition knowledge is interrelated with personal factors and selection goals. It is not necessarily utilized consistently when selecting food products. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Light robotics: aiming towards all-optical nano-robotics

    NASA Astrophysics Data System (ADS)

    Glückstad, Jesper; Palima, Darwin; Banas, Andrew

    2017-04-01

    Light Robotics is a new field of research where ingredients from photonics, nanotechnology and biotechnology are put together in new ways to realize light-driven robotics at the smallest scales to solve major challenges primarily within the nanobio-domain but not limited hereto. Exploring the full potential of this new `drone-like' light-printed, light-driven, light-actuated micro- and nanorobotics in challenging geometries requires a versatile and real-time reconfigurable light addressing that can dynamically track a plurality of tiny tools in 3D to ensure real-time continuous light-delivery on the fly. Our latest developments in this new and exciting research area will be reviewed.

  20. Evaluation of Sensor Configurations for Robotic Surgical Instruments

    PubMed Central

    Gómez-de-Gabriel, Jesús M.; Harwin, William

    2015-01-01

    Designing surgical instruments for robotic-assisted minimally-invasive surgery (RAMIS) is challenging due to constraints on the number and type of sensors imposed by considerations such as space or the need for sterilization. A new method for evaluating the usability of virtual teleoperated surgical instruments based on virtual sensors is presented. This method uses virtual prototyping of the surgical instrument with a dual physical interaction, which allows testing of different sensor configurations in a real environment. Moreover, the proposed approach has been applied to the evaluation of prototypes of a two-finger grasper for lump detection by remote pinching. In this example, the usability of a set of five different sensor configurations, with a different number of force sensors, is evaluated in terms of quantitative and qualitative measures in clinical experiments with 23 volunteers. As a result, the smallest number of force sensors needed in the surgical instrument that ensures the usability of the device can be determined. The details of the experimental setup are also included. PMID:26516863

  1. Evaluation of Sensor Configurations for Robotic Surgical Instruments.

    PubMed

    Gómez-de-Gabriel, Jesús M; Harwin, William

    2015-10-27

    Designing surgical instruments for robotic-assisted minimally-invasive surgery (RAMIS) is challenging due to constraints on the number and type of sensors imposed by considerations such as space or the need for sterilization. A new method for evaluating the usability of virtual teleoperated surgical instruments based on virtual sensors is presented. This method uses virtual prototyping of the surgical instrument with a dual physical interaction, which allows testing of different sensor configurations in a real environment. Moreover, the proposed approach has been applied to the evaluation of prototypes of a two-finger grasper for lump detection by remote pinching. In this example, the usability of a set of five different sensor configurations, with a different number of force sensors, is evaluated in terms of quantitative and qualitative measures in clinical experiments with 23 volunteers. As a result, the smallest number of force sensors needed in the surgical instrument that ensures the usability of the device can be determined. The details of the experimental setup are also included.

  2. A Bevel Gear Quality Inspection System Based on Multi-Camera Vision Technology.

    PubMed

    Liu, Ruiling; Zhong, Dexing; Lyu, Hongqiang; Han, Jiuqiang

    2016-08-25

    Surface defect detection and dimension measurement of automotive bevel gears by manual inspection are costly, inefficient, low speed and low accuracy. In order to solve these problems, a synthetic bevel gear quality inspection system based on multi-camera vision technology is developed. The system can detect surface defects and measure gear dimensions simultaneously. Three efficient algorithms named Neighborhood Average Difference (NAD), Circle Approximation Method (CAM) and Fast Rotation-Position (FRP) are proposed. The system can detect knock damage, cracks, scratches, dents, gibbosity or repeated cutting of the spline, etc. The smallest detectable defect is 0.4 mm × 0.4 mm and the precision of dimension measurement is about 40-50 μm. One inspection process takes no more than 1.3 s. Both precision and speed meet the requirements of real-time online inspection in bevel gear production.

  3. Detection of core-periphery structure in networks based on 3-tuple motifs

    NASA Astrophysics Data System (ADS)

    Ma, Chuang; Xiang, Bing-Bing; Chen, Han-Shuang; Small, Michael; Zhang, Hai-Feng

    2018-05-01

    Detecting mesoscale structure, such as community structure, is of vital importance for analyzing complex networks. Recently, a new mesoscale structure, core-periphery (CP) structure, has been identified in many real-world systems. In this paper, we propose an effective algorithm for detecting CP structure based on a 3-tuple motif. In this algorithm, we first define a 3-tuple motif in terms of the patterns of edges as well as the property of nodes, and then a motif adjacency matrix is constructed based on the 3-tuple motif. Finally, the problem is converted to find a cluster that minimizes the smallest motif conductance. Our algorithm works well in different CP structures: including single or multiple CP structure, and local or global CP structures. Results on the synthetic and the empirical networks validate the high performance of our method.

  4. Smallest worthwhile effect of land-based and water-based pulmonary rehabilitation for COPD.

    PubMed

    McNamara, Renae J; Elkins, Mark R; Ferreira, Manuela L; Spencer, Lissa M; Herbert, Robert D

    2015-05-01

    This study aimed to determine the smallest worthwhile effect of land-based and water-based pulmonary rehabilitation on 6-min walk distance among people with chronic obstructive pulmonary disease (COPD). Using a benefit-harm trade-off method, people with COPD who had completed two baseline 6-min walk tests at the commencement of outpatient pulmonary rehabilitation were presented with two scenarios: 8 weeks of land-based and 8 weeks of water-based pulmonary rehabilitation. Participants were guided through an iterative process allowing them to progressively refine their estimates of the smallest improvement due to each form of rehabilitation that would outweigh the associated costs, risks and inconvenience presented in the scenario. 100 people with COPD participated (mean±sd age 72±9 years, forced expiratory volume in 1 s 54±16% predicted and baseline 6-min walk distance 377±101 m). For land-based pulmonary rehabilitation, the median smallest worthwhile effect was 20 m (95% CI 15-37 m). For water-based pulmonary rehabilitation, the median smallest worthwhile effect was 26 m (95% CI 15-33 m). These estimates did not differ significantly (p=0.10). People with COPD typically perceive that pulmonary rehabilitation would be worthwhile if it increased the 6-min walk distance by about 6%. The smallest worthwhile effects of land- and water-based pulmonary rehabilitation were similar.

  5. Smallest worthwhile effect of land-based and water-based pulmonary rehabilitation for COPD

    PubMed Central

    Elkins, Mark R.; Ferreira, Manuela L.; Spencer, Lissa M.; Herbert, Robert D.

    2015-01-01

    This study aimed to determine the smallest worthwhile effect of land-based and water-based pulmonary rehabilitation on 6-min walk distance among people with chronic obstructive pulmonary disease (COPD). Using a benefit–harm trade-off method, people with COPD who had completed two baseline 6-min walk tests at the commencement of outpatient pulmonary rehabilitation were presented with two scenarios: 8 weeks of land-based and 8 weeks of water-based pulmonary rehabilitation. Participants were guided through an iterative process allowing them to progressively refine their estimates of the smallest improvement due to each form of rehabilitation that would outweigh the associated costs, risks and inconvenience presented in the scenario. 100 people with COPD participated (mean±sd age 72±9 years, forced expiratory volume in 1 s 54±16% predicted and baseline 6-min walk distance 377±101 m). For land-based pulmonary rehabilitation, the median smallest worthwhile effect was 20 m (95% CI 15–37 m). For water-based pulmonary rehabilitation, the median smallest worthwhile effect was 26 m (95% CI 15–33 m). These estimates did not differ significantly (p=0.10). People with COPD typically perceive that pulmonary rehabilitation would be worthwhile if it increased the 6-min walk distance by about 6%. The smallest worthwhile effects of land- and water-based pulmonary rehabilitation were similar. PMID:27730130

  6. A Bevel Gear Quality Inspection System Based on Multi-Camera Vision Technology

    PubMed Central

    Liu, Ruiling; Zhong, Dexing; Lyu, Hongqiang; Han, Jiuqiang

    2016-01-01

    Surface defect detection and dimension measurement of automotive bevel gears by manual inspection are costly, inefficient, low speed and low accuracy. In order to solve these problems, a synthetic bevel gear quality inspection system based on multi-camera vision technology is developed. The system can detect surface defects and measure gear dimensions simultaneously. Three efficient algorithms named Neighborhood Average Difference (NAD), Circle Approximation Method (CAM) and Fast Rotation-Position (FRP) are proposed. The system can detect knock damage, cracks, scratches, dents, gibbosity or repeated cutting of the spline, etc. The smallest detectable defect is 0.4 mm × 0.4 mm and the precision of dimension measurement is about 40–50 μm. One inspection process takes no more than 1.3 s. Both precision and speed meet the requirements of real-time online inspection in bevel gear production. PMID:27571078

  7. Surface hydrophobicity of slippery zones in the pitchers of two Nepenthes species and a hybrid

    PubMed Central

    Wang, Lixin; Zhou, Qiang

    2016-01-01

    To investigate the hydrophobicity of slippery zones, static contact angle measurement and microstructure observation of slippery surfaces from two Nepenthes species and a hybrid were conducted. Marginally different static contact angles were observed, as the smallest (133.83°) and greatest (143.63°) values were recorded for the N. alata and N. miranda respectively, and the median value (140.40°) was presented for the N. khasiana. The slippery zones under investigation exhibited rather similar surface morphologies, but different structural dimensions. These findings probably suggest that the geometrical dimensions of surface architecture exert primary effects on differences in the hydrophobicity of the slippery zone. Based on the Wenzel and Cassie-Baxter equations, models were proposed to analyze the manner in which geometrical dimensions affect the hydrophobicity of the slippery surfaces. The results of our analysis demonstrated that the different structural dimensions of lunate cells and wax platelets make the slippery zones present different real area of the rough surface and thereby generate somewhat distinguishable hydrophobicity. The results support a supplementary interpretation of surface hydrophobicity in plant leaves, and provide a theoretical foundation for developing bioinspired materials with hydrophobic properties and self-cleaning abilities. PMID:26813707

  8. Are health inequalities really not the smallest in the Nordic welfare states? A comparison of mortality inequality in 37 countries.

    PubMed

    Popham, Frank; Dibben, Chris; Bambra, Clare

    2013-05-01

    Research comparing mortality by socioeconomic status has found that inequalities are not the smallest in the Nordic countries. This is in contrast to expectations given these countries' policy focus on equity. An alternative way of studying inequality has been little used to compare inequalities across welfare states and may yield a different conclusion. We used average life expectancy lost per death as a measure of total inequality in mortality derived from death rates from the Human Mortality Database for 37 countries in 2006 that we grouped by welfare state type. We constructed a theoretical 'lowest mortality comparator country' to study, by age, why countries were not achieving the smallest inequality and the highest life expectancy. We also studied life expectancy as there is an important correlation between it and inequality. On average, Nordic countries had the highest life expectancy and smallest inequalities for men but not women. For both men and women, Nordic countries had particularly low younger age mortality contributing to smaller inequality and higher life expectancy. Although older age mortality in the Nordic countries is not the smallest. There was variation within Nordic countries with Sweden, Iceland and Norway having higher life expectancy and smaller inequalities than Denmark and Finland (for men). Our analysis suggests that the Nordic countries do have the smallest inequalities in mortality for men and for younger age groups. However, this is not the case for women. Reducing premature mortality among older age groups would increase life expectancy and reduce inequality further in Nordic countries.

  9. Are health inequalities really not the smallest in the Nordic welfare states? A comparison of mortality inequality in 37 countries

    PubMed Central

    Popham, Frank; Dibben, Chris; Bambra, Clare

    2013-01-01

    Background Research comparing mortality by socioeconomic status has found that inequalities are not the smallest in the Nordic countries. This is in contrast to expectations given these countries’ policy focus on equity. An alternative way of studying inequality has been little used to compare inequalities across welfare states and may yield a different conclusion. Methods We used average life expectancy lost per death as a measure of total inequality in mortality derived from death rates from the Human Mortality Database for 37 countries in 2006 that we grouped by welfare state type. We constructed a theoretical ‘lowest mortality comparator country’ to study, by age, why countries were not achieving the smallest inequality and the highest life expectancy. We also studied life expectancy as there is an important correlation between it and inequality. Results On average, Nordic countries had the highest life expectancy and smallest inequalities for men but not women. For both men and women, Nordic countries had particularly low younger age mortality contributing to smaller inequality and higher life expectancy. Although older age mortality in the Nordic countries is not the smallest. There was variation within Nordic countries with Sweden, Iceland and Norway having higher life expectancy and smaller inequalities than Denmark and Finland (for men). Conclusions Our analysis suggests that the Nordic countries do have the smallest inequalities in mortality for men and for younger age groups. However, this is not the case for women. Reducing premature mortality among older age groups would increase life expectancy and reduce inequality further in Nordic countries. PMID:23386671

  10. A dual-beam spectropluviometer concept

    NASA Astrophysics Data System (ADS)

    Delahaye, J.-Y.; Barthès, L.; Golé, P.; Lavergnat, J.; Vinson, J. P.

    2006-08-01

    SummaryA dual beam spectropluviometer (DBS) measuring the equivalent diameter D, the fall velocity V and the time T of arrival of particles is presented. Its main advantage over previous optical disdrometers is the whole measurement range of atmospheric precipitating particles near the ground. In the bottom part of the size range, 0.1 mm has been the smallest observable diameter. The means for obtaining such results are (i) two uniform infrared beams of rectangular cross-section 2 mm in height, 40 mm in width and 250 mm in length, with a 2 mm vertical gap in-between, (ii) a dual 16-bit analog to digital converter, (iii) a dedicated program for extracting the three parameters in real time by computing the signal slopes and determining the correlation between both channels used in this first version of the instrument, (iv) various means for reducing spurious detections caused by splashing, vibration and sunlight. Laboratory tests and typical rain measurements are shown. The DBS is particularly suited for extensive atmospheric and radio propagation research applications where the smallest drops were not correctly estimated in the distributions because of the lack of appropriate measurement devices.

  11. The New Dual-beam Spectropluviometer Concept

    NASA Astrophysics Data System (ADS)

    Delahaye, J. Y.; Barthes, L.; Golé, P.; Lavergnat, J.; Vinson, J. P.

    A Dual Beam Spectropluviometer (DBS) measuring the equivalent diameter D, the vertical velocity V and the time T of arrival of particles is presented. Its main advan- tage over previous optical disdrometers is the extensive measurement range of atmo- spheric precipitations near ground. In particular, 0.15 mm diameter particles can be observed in quiet laboratory conditions and 0.2 mm is the smallest diameter observed in the outdoor turbulent air velocity field. The means for obtaining such results are (i) two uniform beams of rectangular cross-section 2 mm in height, 40 mm in width and 250 mm in length, with a 2 mm vertical gap, (ii) a dual 16-bit analog to digital converter, (iii) a dedicated program for extracting the 3 parameters in real time by computing the signal slopes and determining the correlation between both channels, (iii) various means for reducing splashing and vibration. Laboratory tests and typical rain measurements are shown. The DBS is particularly suited for extensive atmospheric and radio propagation research applications where the smallest drops were not correctly estimated in the distributions because of the lack of appropriate measurement devices.

  12. Agile science: creating useful products for behavior change in the real world.

    PubMed

    Hekler, Eric B; Klasnja, Predrag; Riley, William T; Buman, Matthew P; Huberty, Jennifer; Rivera, Daniel E; Martin, Cesar A

    2016-06-01

    Evidence-based practice is important for behavioral interventions but there is debate on how best to support real-world behavior change. The purpose of this paper is to define products and a preliminary process for efficiently and adaptively creating and curating a knowledge base for behavior change for real-world implementation. We look to evidence-based practice suggestions and draw parallels to software development. We argue to target three products: (1) the smallest, meaningful, self-contained, and repurposable behavior change modules of an intervention; (2) "computational models" that define the interaction between modules, individuals, and context; and (3) "personalization" algorithms, which are decision rules for intervention adaptation. The "agile science" process includes a generation phase whereby contender operational definitions and constructs of the three products are created and assessed for feasibility and an evaluation phase, whereby effect size estimates/casual inferences are created. The process emphasizes early-and-often sharing. If correct, agile science could enable a more robust knowledge base for behavior change.

  13. Familiarization, validity and smallest detectable difference of the isometric squat test in evaluating maximal strength.

    PubMed

    Drake, David; Kennedy, Rodney; Wallace, Eric

    2018-02-06

    Isometric multi-joint tests are considered reliable and have strong relationships with 1RM performance. However, limited evidence is available for the isometric squat in terms of effects of familiarization and reliability. This study aimed to assess, the effect of familiarization, stability reliability, determine the smallest detectible difference, and the correlation of the isometric squat test with 1RM squat performance. Thirty-six strength-trained participants volunteered to take part in this study. Following three familiarization sessions, test-retest reliability was evaluated with a 48-hour window between each time point. Isometric squat peak, net and relative force were assessed. Results showed three familiarizations were required, isometric squat had a high level of stability reliability and smallest detectible difference of 11% for peak and relative force. Isometric strength at a knee angle of ninety degrees had a strong significant relationship with 1RM squat performance. In conclusion, the isometric squat is a valid test to assess multi-joint strength and can discriminate between strong and weak 1RM squat performance. Changes greater than 11% in peak and relative isometric squat performance should be considered as meaningful in participants who are familiar with the test.

  14. Contributed Review: Camera-limits for wide-field magnetic resonance imaging with a nitrogen-vacancy spin sensor

    NASA Astrophysics Data System (ADS)

    Wojciechowski, Adam M.; Karadas, Mürsel; Huck, Alexander; Osterkamp, Christian; Jankuhn, Steffen; Meijer, Jan; Jelezko, Fedor; Andersen, Ulrik L.

    2018-03-01

    Sensitive, real-time optical magnetometry with nitrogen-vacancy centers in diamond relies on accurate imaging of small (≪10-2), fractional fluorescence changes across the diamond sample. We discuss the limitations on magnetic field sensitivity resulting from the limited number of photoelectrons that a camera can record in a given time. Several types of camera sensors are analyzed, and the smallest measurable magnetic field change is estimated for each type. We show that most common sensors are of a limited use in such applications, while certain highly specific cameras allow achieving nanotesla-level sensitivity in 1 s of a combined exposure. Finally, we demonstrate the results obtained with a lock-in camera that paves the way for real-time, wide-field magnetometry at the nanotesla level and with a micrometer resolution.

  15. Use of a fiber glass optical system to measure the contractile characteristics of a single isolated muscle cell

    NASA Astrophysics Data System (ADS)

    Chen, Chulung; Yin, Shizhuo; Li, Jiang; Yu, Francis T. S.; Cheung, Joseph Y.; Zhang, Xueqian; Lei, Xiaoxiao; Wu, Zhongkong

    1998-05-01

    Cell is the basic structural and fundamental unit of all organisms; the smallest structure capable of performing all the activities vital to life. One goal of current research interest is to learn how the muscle varies the strength of its contraction in response to electric stimuli. A wide variety of techniques have been developed to monitor the mechanical response of isolated cardiac myocytes. Some success has been reported either with the use of intact rat myocytes supported by suction micropipettes or in guinea pig myocytes adhering to glass beams. However, the usual measuring techniques exhibit destructive contact performance on live cells. They could not solve the problem, since the cell may die during or after the time-consuming attachment process at the beginning of each experiment. In contrast, a novel optical system, which consists of a microglass tube with an inner diameter the same size of a real cardiac cell, is proposed to simulate real cell's twitch process. the physical parameters of synthetic cell are well known. By comparing the dynamics of the real cell with that of the simulated cell, the twitch characteristics of the real cell can be measured.

  16. Liver tumor boundaries identified intraoperatively using real-time indocyanine green fluorescence imaging.

    PubMed

    Zhang, Ya-Min; Shi, Rui; Hou, Jian-Cun; Liu, Zi-Rong; Cui, Zi-Lin; Li, Yang; Wu, Di; Shi, Yuan; Shen, Zhong-Yang

    2017-01-01

    Clear delineation between tumors and normal tissues is ideal for real-time surgical navigation imaging. We investigated applying indocyanine green (ICG) fluorescence imaging navigation using an intraoperative administration method in liver resection. Fifty patients who underwent liver resection were divided into two groups based on clinical situation and operative purpose. In group I, sizes of superficial liver tumors were determined; tiny tumors were identified. In group II, the liver resection margin was determined; real-time navigation was performed. ICG was injected intravenously at the beginning of the operation; the liver surface was observed with a photodynamic eye (PDE). Liver resection margins were determined using PDE. Fluorescence contrast between normal liver and tumor tissues was obvious in 32 of 35 patients. A boundary for half the liver or specific liver segments was determined in nine patients by examining the portal vein anatomy after ICG injection. Eight small tumors not observed preoperatively were detected; the smallest was 2 mm. ICG fluorescence imaging navigation is a promising, simple, and safe tool for routine real-time intraoperative imaging during hepatic resection and clinical exploration in hepatocellular carcinoma, enabling high sensibility for identifying liver resection margins and detecting tiny superficial tumors.

  17. Monitoring sedentary patterns in office employees: validity of an m-health tool (Walk@Work-App) for occupational health.

    PubMed

    Bort-Roig, Judit; Puig-Ribera, Anna; Contreras, Ruth S; Chirveches-Pérez, Emilia; Martori, Joan C; Gilson, Nicholas D; McKenna, Jim

    2017-09-15

    This study validated the Walk@Work-Application (W@W-App) for measuring occupational sitting and stepping. The W@W-App was installed on the smartphones of office-based employees (n=17; 10 women; 26±3 years). A prescribed 1-hour laboratory protocol plus two continuous hours of occupational free-living activities were performed. Intra-class correlation coefficients (ICC) compared mean differences of sitting time and step count measurements between the W@W-App and criterion measures (ActivPAL3TM and SW200Yamax Digi-Walker). During the protocol, agreement between self-paced walking (ICC=0.85) and active working tasks step counts (ICC=0.80) was good. The smallest median difference was for sitting time (1.5seconds). During free-living conditions, sitting time (ICC=0.99) and stepping (ICC=0.92) showed excellent agreement, with a difference of 0.5minutes and 18 steps respectively. The W@W-App provided valid measures for monitoring occupational sedentary patterns in real life conditions; a key issue for increasing awareness and changing occupational sedentariness. Copyright © 2017 SESPAS. Publicado por Elsevier España, S.L.U. All rights reserved.

  18. Fetal programming of fat and collagen in porcine skeletal muscles

    PubMed Central

    Karunaratne, JF; Ashton, CJ; Stickland, NC

    2005-01-01

    Connective tissue plays a key role in the scaffolding and development of skeletal muscle. Pilot studies carried out in our laboratory have shown that the smallest porcine littermate has a higher content of connective tissue within skeletal muscle compared with its largest littermate. The present study investigated the prenatal development of intralitter variation in terms of collagen content within connective tissue and intramuscular fat of the M. semitendinosus. Twenty-three pairs of porcine fetuses from a Large White–Landrace origin were used aged from 36 to 86 days of gestation. The largest and smallest littermates were chosen by weight and the M. semitendinosus was removed from each. Complete transverse muscle sections were stained with Oil Red O (detection of lipids) and immunocytochemistry was performed using an antibody to collagen I. Slides were analysed and paired t-Tests revealed the smallest littermate contained a significantly higher proportion of fat deposits and collagen I content compared with the largest littermate. Recent postnatal studies showing elevated levels of intramuscular lipids and low scores for meat tenderness in the smallest littermate corroborate our investigations. It can be concluded that the differences seen in connective tissue elements have a fetal origin that may continue postnatally. PMID:16367803

  19. Microstructure Evolution and Mechanical Behavior of 2219 Aluminum Alloys Additively Fabricated by the Cold Metal Transfer Process

    PubMed Central

    Fang, Xuewei; Li, Hui; Li, Chaolong; Lu, Bingheng

    2018-01-01

    In this research, four different welding arc modes including conventional cold metal transfer (CMT), CMT-Pulse (CMT-P), CMT-Advanced (CMT-ADV), and CMT pulse advanced (CMT-PADV) were used to deposit 2219-Al wire. The effects of different arc modes on porosity, pore size distribution, microstructure evolution, and mechanical properties were thoroughly investigated. The statistical analysis of the porosity and its size distribution indicated that the CMT-PADV process gave the smallest pore area percentage and pore aspect ratio, and had almost no larger pores. The results from optical microscopy, scanning electron microscopy, and fractographic morphology proved that uniform and fine equiaxed grains, evenly distributed Al2Cu second phase particles were formed during the CMT-PADV process. Furthermore, the X-ray diffraction test ascertained that the CMT-PADV sample had the smallest lattice parameter and the highest solute Cu content. Besides, the tensile strength could reach 283 MPa, the data scattering was the smallest, and the strength scattering of the sample in the horizontal direction was the shortest. In addition, the strength properties were nearly isotropic, with only 5 MPa difference in the vertical and horizontal directions. The above mentioned results indicated that the mechanical properties of 2219 aluminum alloy was improved using the CMT-PADV arc mode. PMID:29772708

  20. Microstructure Evolution and Mechanical Behavior of 2219 Aluminum Alloys Additively Fabricated by the Cold Metal Transfer Process.

    PubMed

    Fang, Xuewei; Zhang, Lijuan; Li, Hui; Li, Chaolong; Huang, Ke; Lu, Bingheng

    2018-05-16

    In this research, four different welding arc modes including conventional cold metal transfer (CMT), CMT-Pulse (CMT-P), CMT-Advanced (CMT-ADV), and CMT pulse advanced (CMT-PADV) were used to deposit 2219-Al wire. The effects of different arc modes on porosity, pore size distribution, microstructure evolution, and mechanical properties were thoroughly investigated. The statistical analysis of the porosity and its size distribution indicated that the CMT-PADV process gave the smallest pore area percentage and pore aspect ratio, and had almost no larger pores. The results from optical microscopy, scanning electron microscopy, and fractographic morphology proved that uniform and fine equiaxed grains, evenly distributed Al₂Cu second phase particles were formed during the CMT-PADV process. Furthermore, the X-ray diffraction test ascertained that the CMT-PADV sample had the smallest lattice parameter and the highest solute Cu content. Besides, the tensile strength could reach 283 MPa, the data scattering was the smallest, and the strength scattering of the sample in the horizontal direction was the shortest. In addition, the strength properties were nearly isotropic, with only 5 MPa difference in the vertical and horizontal directions. The above mentioned results indicated that the mechanical properties of 2219 aluminum alloy was improved using the CMT-PADV arc mode.

  1. Impact of left ventricular outflow tract area on systolic outflow velocity in hypertrophic cardiomyopathy: a real-time three-dimensional echocardiographic study

    NASA Technical Reports Server (NTRS)

    Qin, Jian Xin; Shiota, Takahiro; Lever, Harry M.; Rubin, David N.; Bauer, Fabrice; Kim, Yong Jin; Sitges, Marta; Greenberg, Neil L.; Drinko, Jeanne K.; Martin, Maureen; hide

    2002-01-01

    OBJECTIVES: The aim of this study was to use real-time three-dimensional echocardiography (3DE) to investigate the quantitative relation between minimal left ventricular (LV) outflow tract area (A(LVOT)) and maximal LV outflow tract (LVOT) velocity in patients with hypertrophic obstructive cardiomyopathy (HCM). BACKGROUND: In patients with HCM, LVOT velocity should change inversely with minimal A(LVOT) unless LVOT obstruction reduces the pumping capacity of the ventricle. METHODS: A total of 25 patients with HCM with systolic anterior motion (SAM) of the mitral valve leaflets underwent real-time 3DE. The smallest A(LVOT) during systole was measured using anatomically oriented two-dimensional "C-planes" within the pyramidal 3DE volume. Maximal velocity across LVOT was evaluated by two-dimensional Doppler echocardiography (2DE). For comparison with 3DE A(LVOT), the SAM-septal distance was determined by 2DE. RESULTS: Real-time 3DE provided unique information about the dynamic SAM-septal relation during systole, with A(LVOT) ranging from 0.6 to 5.2 cm(2) (mean: 2.2 +/- 1.4 cm(2)). Maximal velocity (v) correlated inversely with A(LVOT) (v = 496 A(LVOT)(-0.80), r = -0.95, p < 0.001), but the exponent (-0.80) was significantly different from -1.0 (95% confidence interval: -0.67 to -0.92), indicating a significant impact of small A(LVOT) on the peak LVOT flow rate. By comparison, the best correlation between velocity and 2DE SAM-septal distance was significantly (p < 0.01) poorer at -0.83, indicating the superiority of 3DE for assessing A(LVOT). CONCLUSIONS: Three-dimensional echocardiography-measured A(LVOT) provides an assessment of HCM geometry that is superior to 2DE methods. These data indicate that the peak LVOT flow rate appears to be significantly decreased by reduced A(LVOT). Real-time 3DE is a potentially valuable clinical tool for assessing patients with HCM.

  2. Development of induction current acquisition device based on ARM

    NASA Astrophysics Data System (ADS)

    Ji, Yanju; Liu, Xiyang; Huang, Wanyu; Yao, Jiang; Yuan, Guiyang; Hui, Luan; Guan, Shanshan

    2018-03-01

    We design an induction current acquisition device based on ARM in order to realize high resolution and high sampling rate of acquisition for the induction current in wire-loop. Considering its characteristics of fast attenuation and small signal amplitude, we use the method of multi-path fusion for noise suppression. In the paper, the design is carried out from three aspects of analog circuit and device selection, independent power supply structure and the electromagnetic interference suppression of high frequency. DMA and ping-pong buffer, as a new data transmission technology, solves real time storage problem of massive data. The performance parameters of ARM acquisition device are tested. The comparison test of ARM acquisition device and cRIO acquisition device is performed at different time constants. The results show that it has 120dB dynamic range, 47kHz bandwidth, 96kHz sampling rate, 5μV the smallest resolution, and its average error value is not more than 4%, which proves the high accuracy and stability of the device.

  3. Electrochemical quantification of the antioxidant capacity of medicinal plants using biosensors.

    PubMed

    Rodríguez-Sevilla, Erika; Ramírez-Silva, María-Teresa; Romero-Romo, Mario; Ibarra-Escutia, Pedro; Palomar-Pardavé, Manuel

    2014-08-08

    The working area of a screen-printed electrode, SPE, was modified with the enzyme tyrosinase (Tyr) using different immobilization methods, namely entrapment with water-soluble polyvinyl alcohol (PVA), cross-linking using glutaraldehyde (GA), and cross-linking using GA and human serum albumin (HSA); the resulting electrodes were termed SPE/Tyr/PVA, SPE/Tyr/GA and SPE/Tyr/HSA/GA, respectively. These biosensors were characterized by means of amperometry and EIS techniques. From amperometric evaluations, the apparent Michaelis-Menten constant, Km', of each biosensor was evaluated while the respective charge transfer resistance, Rct, was assessed from impedance measurements. It was found that the SPE/Tyr/GA had the smallest Km' (57 ± 7) µM and Rct values. This electrode also displayed both the lowest detection and quantification limits for catechol quantification. Using the SPE/Tyr/GA, the Trolox Equivalent Antioxidant Capacity (TEAC) was determined from infusions prepared with "mirto" (Salvia microphylla), "hHierba dulce" (Lippia dulcis) and "salve real" (Lippia alba), medicinal plants commonly used in Mexico.

  4. Between-day reliability of the trapezius muscle H-reflex and M-wave.

    PubMed

    Vangsgaard, Steffen; Hansen, Ernst A; Madeleine, Pascal

    2015-12-01

    The aim of this study was to investigate the between-day reliability of the trapezius muscle H-reflex and M-wave. Sixteen healthy subjects were studied on 2 consecutive days. Trapezius muscle H-reflexes were evoked by electrical stimulation of the C3/4 cervical nerves; M-waves were evoked by electrical stimulation of the accessory nerve. Relative reliability was estimated by intraclass correlation coefficients (ICC2,1 ). Absolute reliability was estimated by computing the standard error of measurement (SEM) and the smallest real difference (SRD). Bland-Altman plots were constructed to detect any systematic bias. Variables showed substantial to excellent relative reliability (ICC = 0.70-0.99). The relative SEM ranged from 1.4% to 34.8%; relative SRD ranged from 3.8% to 96.5%. No systematic bias was present in the data. The amplitude and latency of the trapezius muscle H-reflex and M-wave in healthy young subjects can be measured reliably across days. © 2015 Wiley Periodicals, Inc.

  5. HMGCR inhibits the early stage of PCV2 infection, while PKC enhances the infection at the late stage.

    PubMed

    Ma, Teng; Chen, Xinrong; Ouyang, Hongsheng; Liu, Xiaohui; Ouyang, Ting; Peng, Zhiyuan; Yang, Xin; Chen, Fuwang; Pang, Daxin; Bai, Jieying; Ren, Linzhu

    2017-02-02

    Porcine circovirus type 2 (PCV2) is the smallest DNA virus, which causes porcine circovirus diseases and porcine circovirus-associated diseases (PCVD/PCVAD). Due the small size of viral genomic DNA, PCV2 replication predominantly relies on the host factors. In this study, effects of PKC and HMGCR on PCV2 infection were evaluated using real time PCR and western blot. We found that PKC and HMGCR participated in different stages of PCV2 infection. HMGCR works on the early stage of the infection to inhibit the virus infection, while PKC enhances the infection at the late stage. Furthermore, PKC enhances PCV2 replication by activating JNK1/2 and inactivating HMGCR via regulating phosphorylation of these two proteins, while HMGCR can suppress phosphorylation of JNK1/2. The results in the present study will provide new sights in the pathogenesis of PCV2 infection, as well as interactions between host factors during PCV2 infection. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Isotropic probability measures in infinite-dimensional spaces

    NASA Technical Reports Server (NTRS)

    Backus, George

    1987-01-01

    Let R be the real numbers, R(n) the linear space of all real n-tuples, and R(infinity) the linear space of all infinite real sequences x = (x sub 1, x sub 2,...). Let P sub in :R(infinity) approaches R(n) be the projection operator with P sub n (x) = (x sub 1,...,x sub n). Let p(infinity) be a probability measure on the smallest sigma-ring of subsets of R(infinity) which includes all of the cylinder sets P sub n(-1) (B sub n), where B sub n is an arbitrary Borel subset of R(n). Let p sub n be the marginal distribution of p(infinity) on R(n), so p sub n(B sub n) = p(infinity) (P sub n to the -1 (B sub n)) for each B sub n. A measure on R(n) is isotropic if it is invariant under all orthogonal transformations of R(n). All members of the set of all isotropic probability distributions on R(n) are described. The result calls into question both stochastic inversion and Bayesian inference, as currently used in many geophysical inverse problems.

  7. Cosmological implications of different baryon acoustic oscillation data

    NASA Astrophysics Data System (ADS)

    Wang, Shuang; Hu, YaZhou; Li, Miao

    2017-04-01

    In this work, we explore the cosmological implications of different baryon acoustic oscillation (BAO) data, including the BAO data extracted by using the spherically averaged one-dimensional galaxy clustering (GC) statistics (hereafter BAO1) and the BAO data obtained by using the anisotropic two-dimensional GC statistics (hereafter BAO2). To make a comparison, we also take into account the case without BAO data (hereafter NO BAO). Firstly, making use of these BAO data, as well as the SNLS3 type Ia supernovae sample and the Planck distance priors data, we give the cosmological constraints of the ΛCDM, the wCDM, and the Chevallier-Polarski-Linder (CPL) model. Then, we discuss the impacts of different BAO data on cosmological consquences, including its effects on parameter space, equation of state (EoS), figure of merit (FoM), deceleration-acceleration transition redshift, Hubble parameter H( z), deceleration parameter q( z), statefinder hierarchy S 3 (1)( z), S 4 (1)( z) and cosmic age t( z). We find that: (1) NO BAO data always give a smallest fractional matter density Ω m0, a largest fractional curvature density Ωk0 and a largest Hubble constant h; in contrast, BAO1 data always give a largest Ω m0, a smallest Ω k0 and a smallest h. (2) For the wCDM and the CPL model, NO BAO data always give a largest EoS w; in contrast, BAO2 data always give a smallest w. (3) Compared with the case of BAO1, BAO2 data always give a slightly larger FoM, and thus can give a cosmological constraint with a slightly better accuracy. (4) The impacts of different BAO data on the cosmic evolution and the comic age are very small, and cannot be distinguished by using various dark energy diagnoses and the cosmic age data.

  8. Option pricing: a flexible tool to disseminate shared savings contracts.

    PubMed

    Friedberg, Mark W; Buendia, Anthony M; Lauderdale, Katherine E; Hussey, Peter S

    2013-08-01

    Due to volatility in healthcare costs, shared savings contracts can create systematic financial losses for payers, especially when contracting with smaller providers. To improve the business case for shared savings, we calculated the prices of financial options that payers can "sell" to providers to offset these losses. Using 2009 to 2010 member-level total cost of care data from a large commercial health plan, we calculated option prices by applying a bootstrap simulation procedure. We repeated these simulations for providers of sizes ranging from 500 to 60,000 patients and for shared savings contracts with and without key design features (minimum savings thresholds,bonus caps, cost outlier truncation, and downside risk) and under assumptions of zero, 1%, and 2% real cost reductions due to the shared savings contracts. Assuming no real cost reduction and a 50% shared savings rate, per patient option prices ranged from $225 (3.1% of overall costs) for 500-patient providers to $23 (0.3%) for 60,000-patient providers. Introducing minimum savings thresholds, bonus caps, cost outlier truncation, and downside risk reduced these option prices. Option prices were highly sensitive to the magnitude of real cost reductions. If shared savings contracts cause 2% reductions in total costs, option prices fall to zero for all but the smallest providers. Calculating the prices of financial options that protect payers and providers from downside risk can inject flexibility into shared savings contracts, extend such contracts to smaller providers, and clarify the tradeoffs between different contract designs, potentially speeding the dissemination of shared savings.

  9. Characterization of a Hybrid Optical Microscopy/Laser Ablation Liquid Vortex Capture/Electrospray Ionization System for Mass Spectrometry Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cahill, John F.; Kertesz, Vilmos; Van Berkel, Gary J.

    Herein, a commercial optical microscope, laser microdissection instrument was coupled with an electrospray ionization mass spectrometer via a low profile liquid vortex capture probe to yield a hybrid optical microscopy/mass spectrometry imaging system. The instrument has bright-field and fluorescence microscopy capabilities in addition to a highly focused UV laser beam that is utilized for laser ablation of samples. With this system, material laser ablated from a sample using the microscope was caught by a liquid vortex capture probe and transported in solution for analysis by electrospray ionization mass spectrometry. Both lane scanning and spot sampling mass spectral imaging modes weremore » used. The smallest area the system was able to ablate was ~0.544 μm × ~0.544 μm, achieved by oversampling of the smallest laser ablation spot size that could be obtained (~1.9 μm). With use of a model photoresist surface, known features as small as ~1.5 μm were resolved. The capabilities of the system with real world samples were demonstrated first with a blended polymer thin film containing poly(2-vinylpyridine) and poly(N-vinylcarbazole). Using spot sampling imaging, sub-micrometer sized features (0.62, 0.86, and 0.98 μm) visible by optical microscopy were clearly distinguished in the mass spectral images. A second real world example showed the imaging of trace amounts of cocaine in mouse brain thin tissue sections. Lastly, with use of a lane scanning mode with ~6 μm × ~6 μm data pixels, features in the tissue as small as 15 μm in size could be distinguished in both the mass spectral and optical images.« less

  10. Characterization of a Hybrid Optical Microscopy/Laser Ablation Liquid Vortex Capture/Electrospray Ionization System for Mass Spectrometry Imaging

    DOE PAGES

    Cahill, John F.; Kertesz, Vilmos; Van Berkel, Gary J.

    2015-10-22

    Herein, a commercial optical microscope, laser microdissection instrument was coupled with an electrospray ionization mass spectrometer via a low profile liquid vortex capture probe to yield a hybrid optical microscopy/mass spectrometry imaging system. The instrument has bright-field and fluorescence microscopy capabilities in addition to a highly focused UV laser beam that is utilized for laser ablation of samples. With this system, material laser ablated from a sample using the microscope was caught by a liquid vortex capture probe and transported in solution for analysis by electrospray ionization mass spectrometry. Both lane scanning and spot sampling mass spectral imaging modes weremore » used. The smallest area the system was able to ablate was ~0.544 μm × ~0.544 μm, achieved by oversampling of the smallest laser ablation spot size that could be obtained (~1.9 μm). With use of a model photoresist surface, known features as small as ~1.5 μm were resolved. The capabilities of the system with real world samples were demonstrated first with a blended polymer thin film containing poly(2-vinylpyridine) and poly(N-vinylcarbazole). Using spot sampling imaging, sub-micrometer sized features (0.62, 0.86, and 0.98 μm) visible by optical microscopy were clearly distinguished in the mass spectral images. A second real world example showed the imaging of trace amounts of cocaine in mouse brain thin tissue sections. Lastly, with use of a lane scanning mode with ~6 μm × ~6 μm data pixels, features in the tissue as small as 15 μm in size could be distinguished in both the mass spectral and optical images.« less

  11. Study on the fixed point in crustal deformation before strong earthquake

    NASA Astrophysics Data System (ADS)

    Niu, A.; Li, Y.; Yan, W. Mr

    2017-12-01

    Usually, scholars believe that the fault pre-sliding or expansion phenomenon will be observed near epicenter area before strong earthquake, but more and more observations show that the crust deformation nearby epicenter area is smallest(Zhou, 1997; Niu,2009,2012;Bilham, 2005; Amoruso et al., 2010). The theory of Fixed point t is a branch of mathematics that arises from the theory of topological transformation and has important applications in obvious model analysis. An important precursory was observed by two tilt-meter sets, installed at Wenchuan Observatory in the epicenter area, that the tilt changes were the smallest compared with the other 8 stations around them in one year before the Wenchuan earthquake. To subscribe the phenomenon, we proposed the minimum annual variation range that used as a topological transformation. The window length is 1 year, and the sliding length is 1 day. The convergence of points with minimum annual change in the 3 years before the Wenchuan earthquake is studied. And the results show that the points with minimum deformation amplitude basically converge to the epicenter region before the earthquake. The possible mechanism of fixed point of crustal deformation was explored. Concerning the fixed point of crust deformation, the liquidity of lithospheric medium and the isostasy theory are accepted by many scholars (Bott &Dean, 1973; Merer et al.1988; Molnar et al., 1975,1978; Tapponnier et al., 1976; Wang et al., 2001). To explain the fixed point of crust deformation before earthquakes, we study the plate bending model (Bai, et al., 2003). According to plate bending model and real deformation data, we have found that the earthquake rupture occurred around the extreme point of plate bending, where the velocities of displacement, tilt, strain, gravity and so on are close to zero, and the fixed points are located around the epicenter.The phenomenon of fixed point of crust deformation is different from former understandings about the earthquake rupture precursor. 1) The observations for crust deformation in natural conditions are different with dry and static experiments, and the former had the meaning of stress wave.2)The earthquake rupture has a special triggering mechanism that is different from the experiment with limited scale rock fracture.

  12. Near Real-Time Monitoring of Forest Disturbance: A Multi-Sensor Remote Sensing Approach and Assessment Framework

    NASA Astrophysics Data System (ADS)

    Tang, Xiaojing

    Fast and accurate monitoring of tropical forest disturbance is essential for understanding current patterns of deforestation as well as helping eliminate illegal logging. This dissertation explores the use of data from different satellites for near real-time monitoring of forest disturbance in tropical forests, including: development of new monitoring methods; development of new assessment methods; and assessment of the performance and operational readiness of existing methods. Current methods for accuracy assessment of remote sensing products do not address the priority of near real-time monitoring of detecting disturbance events as early as possible. I introduce a new assessment framework for near real-time products that focuses on the timing and the minimum detectable size of disturbance events. The new framework reveals the relationship between change detection accuracy and the time needed to identify events. In regions that are frequently cloudy, near real-time monitoring using data from a single sensor is difficult. This study extends the work by Xin et al. (2013) and develops a new time series method (Fusion2) based on fusion of Landsat and MODIS (Moderate Resolution Imaging Spectroradiometer) data. Results of three test sites in the Amazon Basin show that Fusion2 can detect 44.4% of the forest disturbance within 13 clear observations (82 days) after the initial disturbance. The smallest event detected by Fusion2 is 6.5 ha. Also, Fusion2 detects disturbance faster and has less commission error than more conventional methods. In a comparison of coarse resolution sensors, MODIS Terra and Aqua combined provides faster and more accurate detection of disturbance events than VIIRS (Visible Infrared Imaging Radiometer Suite) and MODIS single sensor data. The performance of near real-time monitoring using VIIRS is slightly worse than MODIS Terra but significantly better than MODIS Aqua. New monitoring methods developed in this dissertation provide forest protection organizations the capacity to monitor illegal logging events promptly. In the future, combining two Landsat and two Sentinel-2 satellites will provide global coverage at 30 m resolution every 4 days, and routine monitoring may be possible at high resolution. The methods and assessment framework developed in this dissertation are adaptable to newly available datasets.

  13. REVIEWS OF TOPICAL PROBLEMS Molecular energy transducers of the living cell. Proton ATP synthase: a rotating molecular motor

    NASA Astrophysics Data System (ADS)

    Romanovsky, Yurii M.; Tikhonov, Alexander N.

    2010-12-01

    The free energy released upon the enzymatic hydrolysis of adenosine triphosphate (ATP) is the main source of energy for the functioning of the living cell and all multicellular organisms. The overwhelming majority of ATP molecules are formed by proton ATP synthases, which are the smallest macromolecular electric motors in Nature. This paper reviews the modern concepts of the molecular structure and functioning of the proton ATP synthase, and real-time biophysical experiments on the rotation of the 'rotor' of this macromolecular motor. Some mathematical models describing the operation of this nanosized macromolecular machine are described.

  14. LETTER TO THE EDITOR: Fractal diffusion coefficient from dynamical zeta functions

    NASA Astrophysics Data System (ADS)

    Cristadoro, Giampaolo

    2006-03-01

    Dynamical zeta functions provide a powerful method to analyse low-dimensional dynamical systems when the underlying symbolic dynamics is under control. On the other hand, even simple one-dimensional maps can show an intricate structure of the grammar rules that may lead to a non-smooth dependence of global observables on parameters changes. A paradigmatic example is the fractal diffusion coefficient arising in a simple piecewise linear one-dimensional map of the real line. Using the Baladi-Ruelle generalization of the Milnor-Thurnston kneading determinant, we provide the exact dynamical zeta function for such a map and compute the diffusion coefficient from its smallest zero.

  15. A prospective, multisite, international validation of the Complex Regional Pain Syndrome Severity Score.

    PubMed

    Harden, R Norman; Maihofner, Christian; Abousaad, Elias; Vatine, Jean-Jacques; Kirsling, Amy; Perez, Roberto S G M; Kuroda, Maxine; Brunner, Florian; Stanton-Hicks, Michael; Marinus, Johan; van Hilten, Jacobus J; Mackey, Sean; Birklein, Frank; Schlereth, Tanja; Mailis-Gagnon, Angela; Graciosa, Joe; Connoly, Sara B; Dayanim, David; Massey, Michael; Frank, Hadas; Livshitz, Anatoly; Bruehl, Stephen

    2017-08-01

    Clinical diagnosis of complex regional pain syndrome (CRPS) is a dichotomous (yes/no) categorization, a format necessary for clinical decision making. Such dichotomous diagnostic categories do not convey an individual's subtle gradations in the severity of the condition over time and have poor statistical power when used as an outcome measure in research. This prospective, international, multicenter study slightly modified and further evaluated the validity of the CRPS Severity Score (CSS), a continuous index of CRPS severity. Using a prospective design, medical evaluations were conducted in 156 patients with CRPS to compare changes over time in CSS scores between patients initiating a new treatment program and patients on stable treatment regimens. New vs stable categorizations were supported by greater changes in pain and function in the former. Results indicated that CSS values in the stable CRPS treatment group exhibited much less change over time relative to the new treatment group, with intraclass correlations nearly twice as large in the former. A calculated smallest real difference value revealed that a change in the CSS of ≥4.9 scale points would indicate real differences in CRPS symptomatology (with 95% confidence). Across groups, larger changes in CRPS features on the CSS over time were associated in the expected direction with greater changes in pain intensity, fatigue, social functioning, ability to engage in physical roles, and general well-being. The overall pattern of findings further supports the validity of the CSS as a measure of CRPS severity and suggests it may prove useful in clinical monitoring and outcomes research.

  16. Evaluation of attenuation and scatter correction requirements in small animal PET and SPECT imaging

    NASA Astrophysics Data System (ADS)

    Konik, Arda Bekir

    Positron emission tomography (PET) and single photon emission tomography (SPECT) are two nuclear emission-imaging modalities that rely on the detection of high-energy photons emitted from radiotracers administered to the subject. The majority of these photons are attenuated (absorbed or scattered) in the body, resulting in count losses or deviations from true detection, which in turn degrades the accuracy of images. In clinical emission tomography, sophisticated correction methods are often required employing additional x-ray CT or radionuclide transmission scans. Having proven their potential in both clinical and research areas, both PET and SPECT are being adapted for small animal imaging. However, despite the growing interest in small animal emission tomography, little scientific information exists about the accuracy of these correction methods on smaller size objects, and what level of correction is required. The purpose of this work is to determine the role of attenuation and scatter corrections as a function of object size through simulations. The simulations were performed using Interactive Data Language (IDL) and a Monte Carlo based package, Geant4 application for emission tomography (GATE). In IDL simulations, PET and SPECT data acquisition were modeled in the presence of attenuation. A mathematical emission and attenuation phantom approximating a thorax slice and slices from real PET/CT data were scaled to 5 different sizes (i.e., human, dog, rabbit, rat and mouse). The simulated emission data collected from these objects were reconstructed. The reconstructed images, with and without attenuation correction, were compared to the ideal (i.e., non-attenuated) reconstruction. Next, using GATE, scatter fraction values (the ratio of the scatter counts to the total counts) of PET and SPECT scanners were measured for various sizes of NEMA (cylindrical phantoms representing small animals and human), MOBY (realistic mouse/rat model) and XCAT (realistic human model) digital phantoms. In addition, PET projection files for different sizes of MOBY phantoms were reconstructed in 6 different conditions including attenuation and scatter corrections. Selected regions were analyzed for these different reconstruction conditions and object sizes. Finally, real mouse data from the real version of the same small animal PET scanner we modeled in our simulations were analyzed for similar reconstruction conditions. Both our IDL and GATE simulations showed that, for small animal PET and SPECT, even the smallest size objects (˜2 cm diameter) showed ˜15% error when both attenuation and scatter were not corrected. However, a simple attenuation correction using a uniform attenuation map and object boundary obtained from emission data significantly reduces this error in non-lung regions (˜1% for smallest size and ˜6% for largest size). In lungs, emissions values were overestimated when only attenuation correction was performed. In addition, we did not observe any significant improvement between the uses of uniform or actual attenuation map (e.g., only ˜0.5% for largest size in PET studies). The scatter correction was not significant for smaller size objects, but became increasingly important for larger sizes objects. These results suggest that for all mouse sizes and most rat sizes, uniform attenuation correction can be performed using emission data only. For smaller sizes up to ˜ 4 cm, scatter correction is not required even in lung regions. For larger sizes if accurate quantization needed, additional transmission scan may be required to estimate an accurate attenuation map for both attenuation and scatter corrections.

  17. Comparison of the Characteristics and Performance of Flurbiprofen 8.75 mg Spray for Sore Throat.

    PubMed

    Veale, David; Shephard, Adrian; Adams, Verity; Lidster, Charlotte

    2017-01-01

    Sore throat sprays provide targeted relief by delivering the active ingredient directly to the site of pain. Different sprays vary in characteristics, thus affecting delivery of the active ingredient to the throat, which can impact compliance. The characteristics and performance of FLURBIPROFEN 8.75 mg SPRAY were compared with 12 other sprays. Parameters assessed included spray angle and pattern, droplet size distribution, shot weight uniformity and shot weight throughout life. Among all sprays tested WICK Sulagil Halsspray had the smallest spray angle (46°) and also the smallest diameter spray pattern (X=32.8 mm; Y=34.4 mm). Thiovalone® Buccal Spray Suspension had both the largest spray angle (82°) and largest diameter spray pattern (X=62.6 mm; Y=78.0 mm). Hasco Sept® Aerosol Spray had the smallest droplet size (Dv90=118.4 μm) whereas OKi infiammazione e dolore® 0.16% spray had the largest (Dv90=214.34 μm). In terms of shot weight uniformity, TANTUM® VERDE GOLA 0.25% spray showed the least variation (2% RSD) between shots and UNIBEN Aerosol Spray the most (23.4% RSD). Shot weight throughout life studies showed that FLURBIPROFEN 8.75 mg SPRAY had the least deviation from shot weight (1.77%) whereas OKi infiammazione e dolore® 0.16% spray deviated the most (44.9%). FLURBIPROFEN 8.75 mg SPRAY had the second smallest spray angle/pattern and droplet size distribution and also the least variation in shot weight. Different sore throat sprays vary in different attributes, affecting delivery of the active ingredient. FLURBIPROFEN 8.75 mg SPRAY performed well overall, ranking first among all sprays tested, and providing a dose which is targeted and uniformly delivered throughout the life of the bottle. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  18. The Jebsen Taylor Test of Hand Function: A Pilot Test-Retest Reliability Study in Typically Developing Children.

    PubMed

    Reedman, Sarah Elizabeth; Beagley, Simon; Sakzewski, Leanne; Boyd, Roslyn N

    2016-08-01

    The aim of this pilot study was to evaluate reproducibility of the Jebsen Taylor Test of Hand Function (JTTHF) in children. Eighty-seven typically developing children 5 to 10 years old were included from five Outside School Hours Care centers in the Greater Brisbane Region, Australia. Hand function was assessed on two occasions with a modified JTTHF, then reproducibility was assessed using Intraclass Correlation Coefficient (ICC [3,1]) and the Standard Error of Measurement (SEM). Total scores for male and female children were not significantly different. Five-year-old children were significantly different to all other age groups and were excluded from further analysis. Results for 71 children, 6 to 10 years old were analyzed (mean age 8.31 years (SD 1.32); 33 males). Test-retest reliability for total scores on the dominant and nondominant hands were ICC 0.74 (95% CI 0.61, 0.83) and ICC 0.72 (95% CI 0.59, 0.82), respectively. 'Writing' and 'Simulated Feeding' subtests demonstrated poor reproducibility. The Smallest Real Difference was 5.09 seconds for total score on the dominant hand. Findings indicate good test-retest reliability for the JTTHF total score to measure hand function in typically developing children aged 6 to 10 years.

  19. Differential expression analysis for RNAseq using Poisson mixed models

    PubMed Central

    Sun, Shiquan; Hood, Michelle; Scott, Laura; Peng, Qinke; Mukherjee, Sayan; Tung, Jenny

    2017-01-01

    Abstract Identifying differentially expressed (DE) genes from RNA sequencing (RNAseq) studies is among the most common analyses in genomics. However, RNAseq DE analysis presents several statistical and computational challenges, including over-dispersed read counts and, in some settings, sample non-independence. Previous count-based methods rely on simple hierarchical Poisson models (e.g. negative binomial) to model independent over-dispersion, but do not account for sample non-independence due to relatedness, population structure and/or hidden confounders. Here, we present a Poisson mixed model with two random effects terms that account for both independent over-dispersion and sample non-independence. We also develop a scalable sampling-based inference algorithm using a latent variable representation of the Poisson distribution. With simulations, we show that our method properly controls for type I error and is generally more powerful than other widely used approaches, except in small samples (n <15) with other unfavorable properties (e.g. small effect sizes). We also apply our method to three real datasets that contain related individuals, population stratification or hidden confounders. Our results show that our method increases power in all three data compared to other approaches, though the power gain is smallest in the smallest sample (n = 6). Our method is implemented in MACAU, freely available at www.xzlab.org/software.html. PMID:28369632

  20. The smallest natural high-active luciferase: cloning and characterization of novel 16.5-kDa luciferase from copepod Metridia longa.

    PubMed

    Markova, Svetlana V; Larionova, Marina D; Burakova, Ludmila P; Vysotski, Eugene S

    2015-01-30

    Coelenterazine-dependent copepod luciferases containing natural signal peptide for secretion are a very convenient analytical tool as they enable monitoring of intracellular events with high sensitivity, without destroying cells or tissues. This property is well suited for application in biomedical research and development of cell-based assays for high throughput screening. We report the cloning of cDNA gene encoding a novel secreted non-allelic 16.5-kDa isoform (MLuc7) of Metridia longa luciferase, which, in fact, is the smallest natural luciferase of known for today. Despite the small size, isoform contains 10 conservative Cys residues suggesting the presence of up to 5 SS bonds. This hampers the efficient production of functionally active recombinant luciferase in bacterial expression systems. With the use of the baculovirus expression system, we produced substantial amounts of the proper folded MLuc7 luciferase with a yield of ∼3 mg/L of a high purity protein. We demonstrate that MLuc7 produced in insect cells is highly active and extremely thermostable, and is well suited as a secreted reporter when expressed in mammalian cells ensuring higher sensitivity of detection as compared to another Metridia luciferase isoform (MLuc164) which is widely employed in real-time imaging. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Using walker during walking: a pilot study for health elder.

    PubMed

    Po-Chan, Yeh; Cherng-Yee, Leung

    2012-01-01

    Walker operation completely relies on the walker handle, however most marketed walkers possess two horizontal handles. Several researchers have suggested that horizontal handles might lead to wrist injury. Therefore, the purpose of this study is to assess the relevant design aspects of walker for elderly people. 28 elders participated in this study; when the experiment was started, subject walked on the tile for 3 meter distance twice by using walker. Data for analysis were selected at the corresponding wrist deviation and vertical force. The results showed that during walker using, the mean wrist deviation was greater than zero. The largest vertical force is significantly larger than the smallest one, and different wrist deviation occurred at three phases, the largest wrist deviation while raising walker is larger than the smallest one, however, no significant different was found between the largest and smallest wrist deviation while pressing walker. No significant correlation occurred between weight and wrist deviation. The correlation between weight and vertical force was significantly positive. With wrist deviation walker use may cause injury to upper-limb, however wrists remain in a neutral position during hand movement to prevent damage. The findings of this study should improve the design of walker handles to reduce the wrist deviations of users.

  2. Contrast-enhanced Magnetic Resonance Imaging of Pelvic Bone Metastases at 3.0 T: Comparison Between 3-dimensional T1-weighted CAIPIRINHA-VIBE Sequence and 2-dimensional T1-weighted Turbo Spin-Echo Sequence.

    PubMed

    Yoon, Min A; Hong, Suk-Joo; Lee, Kyu-Chong; Lee, Chang Hee

    2018-06-12

    This study aimed to compare 3-dimensional T1-weighted gradient-echo sequence (CAIPIRINHA-volumetric interpolated breath-hold examination [VIBE]) with 2-dimensional T1-weighted turbo spin-echo sequence for contrast-enhanced magnetic resonance imaging (MRI) of pelvic bone metastases at 3.0 T. Thirty-one contrast-enhanced MRIs of pelvic bone metastases were included. Two contrast-enhanced sequences were evaluated for the following parameters: overall image quality, sharpness of pelvic bone, iliac vessel clarity, artifact severity, and conspicuity and edge sharpness of the smallest metastases. Quantitative analysis was performed by calculating signal-to-noise ratio and contrast-to-noise ratio of the smallest metastases. Significant differences between the 2 sequences were assessed. CAIPIRINHA-VIBE had higher scores for overall image quality, pelvic bone sharpness, iliac vessel clarity, and edge sharpness of the metastatic lesions, and had less artifacts (all P < 0.05). There was no significant difference in conspicuity, signal-to-noise ratio, or contrast-to-noise ratio of the smallest metastases (P > 0.05). Our results suggest that CAIPIRINHA-VIBE may be superior to turbo spin-echo for contrast-enhanced MRI of pelvic bone metastases at 3.0 T.

  3. Isotropic probability measures in infinite dimensional spaces: Inverse problems/prior information/stochastic inversion

    NASA Technical Reports Server (NTRS)

    Backus, George

    1987-01-01

    Let R be the real numbers, R(n) the linear space of all real n-tuples, and R(infinity) the linear space of all infinite real sequences x = (x sub 1, x sub 2,...). Let P sub n :R(infinity) approaches R(n) be the projection operator with P sub n (x) = (x sub 1,...,x sub n). Let p(infinity) be a probability measure on the smallest sigma-ring of subsets of R(infinity) which includes all of the cylinder sets P sub n(-1) (B sub n), where B sub n is an arbitrary Borel subset of R(n). Let p sub n be the marginal distribution of p(infinity) on R(n), so p sub n(B sub n) = p(infinity)(P sub n to the -1(B sub n)) for each B sub n. A measure on R(n) is isotropic if it is invariant under all orthogonal transformations of R(n). All members of the set of all isotropic probability distributions on R(n) are described. The result calls into question both stochastic inversion and Bayesian inference, as currently used in many geophysical inverse problems.

  4. 40 CFR 92.102 - Definitions and abbreviations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) CONTROL OF AIR POLLUTION FROM LOCOMOTIVES AND LOCOMOTIVE ENGINES Test Procedures § 92.102...), also apply: Accuracy means the difference between the measured value and the true value, where the true... otherwise. Readability means the smallest difference in measured values that can be detected. For example...

  5. 40 CFR 92.102 - Definitions and abbreviations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) CONTROL OF AIR POLLUTION FROM LOCOMOTIVES AND LOCOMOTIVE ENGINES Test Procedures § 92.102...), also apply: Accuracy means the difference between the measured value and the true value, where the true... otherwise. Readability means the smallest difference in measured values that can be detected. For example...

  6. 40 CFR 92.102 - Definitions and abbreviations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) CONTROL OF AIR POLLUTION FROM LOCOMOTIVES AND LOCOMOTIVE ENGINES Test Procedures § 92.102...), also apply: Accuracy means the difference between the measured value and the true value, where the true... otherwise. Readability means the smallest difference in measured values that can be detected. For example...

  7. 40 CFR 92.102 - Definitions and abbreviations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) CONTROL OF AIR POLLUTION FROM LOCOMOTIVES AND LOCOMOTIVE ENGINES Test Procedures § 92.102...), also apply: Accuracy means the difference between the measured value and the true value, where the true... otherwise. Readability means the smallest difference in measured values that can be detected. For example...

  8. Flow Cytometry of Human Primary Epidermal and Follicular Keratinocytes

    PubMed Central

    Gragnani, Alfredo; Ipolito, Michelle Zampieri; Sobral, Christiane S; Brunialti, Milena Karina Coló; Salomão, Reinaldo; Ferreira, Lydia Masako

    2008-01-01

    Objective: The aim of this study was to characterize using flow cytometry cultured human primary keratinocytes isolated from the epidermis and hair follicles by different methods. Methods: Human keratinocytes derived from discarded fragments of total skin and scalp hair follicles from patients who underwent plastic surgery in the Plastic Surgery Division at UNIFESP were used. The epidermal keratinocytes were isolated by using 3 different methods: the standard method, upon exposure to trypsin for 30 minutes; the second, by treatment with dispase for 18 hours and with trypsin for 10 minutes; and the third, by treatment with dispase for 18 hours and with trypsin for 30 minutes. Follicular keratinocytes were isolated using the standard method. Results: On comparing the group treated with dispase for 18 hours and with trypsin for 10 minutes with the group treated with dispase for 18 hours and with trypsin for 30 minutes, it was observed that the first group presented the largest number of viable cells, the smallest number of cells in late apoptosis and necrosis with statistical significance, and no difference in apoptosis. When we compared the group treated with dispase for 18 hours and with trypsin for 10 minutes with the group treated with trypsin, the first group presented the largest number of viable cells, the smallest number of cells in apoptosis with statistical significance, and no difference in late apoptosis and necrosis. When we compared the results of the group treated with dispase for 18 hours and with trypsin for 10 minutes with the results for follical isolation, there was a statistical difference in apoptosis and viable cells. Conclusion: The isolation method of treatment with dispase for 18 hours and with trypsin for 10 minutes produced the largest number of viable cells and the smallest number of cells in apoptosis/necrosis. PMID:18350110

  9. Flow cytometry of human primary epidermal and follicular keratinocytes.

    PubMed

    Gragnani, Alfredo; Ipolito, Michelle Zampieri; Sobral, Christiane S; Brunialti, Milena Karina Coló; Salomão, Reinaldo; Ferreira, Lydia Masako

    2008-02-19

    The aim of this study was to characterize using flow cytometry cultured human primary keratinocytes isolated from the epidermis and hair follicles by different methods. Human keratinocytes derived from discarded fragments of total skin and scalp hair follicles from patients who underwent plastic surgery in the Plastic Surgery Division at UNIFESP were used. The epidermal keratinocytes were isolated by using 3 different methods: the standard method, upon exposure to trypsin for 30 minutes; the second, by treatment with dispase for 18 hours and with trypsin for 10 minutes; and the third, by treatment with dispase for 18 hours and with trypsin for 30 minutes. Follicular keratinocytes were isolated using the standard method. On comparing the group treated with dispase for 18 hours and with trypsin for 10 minutes with the group treated with dispase for 18 hours and with trypsin for 30 minutes, it was observed that the first group presented the largest number of viable cells, the smallest number of cells in late apoptosis and necrosis with statistical significance, and no difference in apoptosis. When we compared the group treated with dispase for 18 hours and with trypsin for 10 minutes with the group treated with trypsin, the first group presented the largest number of viable cells, the smallest number of cells in apoptosis with statistical significance, and no difference in late apoptosis and necrosis. When we compared the results of the group treated with dispase for 18 hours and with trypsin for 10 minutes with the results for follical isolation, there was a statistical difference in apoptosis and viable cells. The isolation method of treatment with dispase for 18 hours and with trypsin for 10 minutes produced the largest number of viable cells and the smallest number of cells in apoptosis/necrosis.

  10. An in-plane solid-liquid-solid growth mode for self-avoiding lateral silicon nanowires.

    PubMed

    Yu, Linwei; Alet, Pierre-Jean; Picardi, Gennaro; Roca i Cabarrocas, Pere

    2009-03-27

    We report an in-plane solid-liquid-solid (IPSLS) mode for obtaining self-avoiding lateral silicon nanowires (SiNW) in a reacting-gas-free annealing process, where the growth of SiNWs is guided by liquid indium drops that transform the surrounding a-SiratioH matrix into crystalline SiNWs. The SiNWs can be approximately mm long, with the smallest diameter down to approximately 22 nm. A high growth rate of >10(2) nm/s and rich evolution dynamics are revealed in a real-time in situ scanning electron microscopy observation. A qualitative growth model is proposed to account for the major features of this IPSLS SiNW growth mode.

  11. System identification of analytical models of damped structures

    NASA Technical Reports Server (NTRS)

    Fuh, J.-S.; Chen, S.-Y.; Berman, A.

    1984-01-01

    A procedure is presented for identifying linear nonproportionally damped system. The system damping is assumed to be representable by a real symmetric matrix. Analytical mass, stiffness and damping matrices which constitute an approximate representation of the system are assumed to be available. Given also are an incomplete set of measured natural frequencies, damping ratios and complex mode shapes of the structure, normally obtained from test data. A method is developed to find the smallest changes in the analytical model so that the improved model can exactly predict the measured modal parameters. The present method uses the orthogonality relationship to improve mass and damping matrices and the dynamic equation to find the improved stiffness matrix.

  12. Quantitative characterization of surface topography using spectral analysis

    NASA Astrophysics Data System (ADS)

    Jacobs, Tevis D. B.; Junge, Till; Pastewka, Lars

    2017-03-01

    Roughness determines many functional properties of surfaces, such as adhesion, friction, and (thermal and electrical) contact conductance. Recent analytical models and simulations enable quantitative prediction of these properties from knowledge of the power spectral density (PSD) of the surface topography. The utility of the PSD is that it contains statistical information that is unbiased by the particular scan size and pixel resolution chosen by the researcher. In this article, we first review the mathematical definition of the PSD, including the one- and two-dimensional cases, and common variations of each. We then discuss strategies for reconstructing an accurate PSD of a surface using topography measurements at different size scales. Finally, we discuss detecting and mitigating artifacts at the smallest scales, and computing upper/lower bounds on functional properties obtained from models. We accompany our discussion with virtual measurements on computer-generated surfaces. This discussion summarizes how to analyze topography measurements to reconstruct a reliable PSD. Analytical models demonstrate the potential for tuning functional properties by rationally tailoring surface topography—however, this potential can only be achieved through the accurate, quantitative reconstruction of the PSDs of real-world surfaces.

  13. Making the case for mobile cognition: EEG and sports performance.

    PubMed

    Park, Joanne L; Fairweather, Malcolm M; Donaldson, David I

    2015-05-01

    In the high stakes world of International sport even the smallest change in performance can make the difference between success and failure, leading sports professionals to become increasingly interested in the potential benefits of neuroimaging. Here we describe evidence from EEG studies that either identify neural signals associated with expertise in sport, or employ neurofeedback to improve performance. Evidence for the validity of neurofeedback as a technique for enhancing sports performance remains limited. By contrast, progress in characterizing the neural correlates of sporting behavior is clear: frequency domain studies link expert performance to changes in alpha rhythms, whilst time-domain studies link expertise in response evaluation and motor output with modulations of P300 effects and readiness potentials. Despite early promise, however, findings have had relatively little impact for sports professionals, at least in part because there has been a mismatch between lab tasks and real sporting activity. After selectively reviewing existing findings and outlining limitations, we highlight developments in mobile EEG technology that offer new opportunities for sports neuroscience. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  14. Providing pressure inputs to multizone building models

    DOE PAGES

    Herring, Steven J.; Batchelor, Simon; Bieringer, Paul E.; ...

    2016-02-13

    A study to assess how the fidelity of wind pressure inputs and indoor model complexity affect the predicted air change rate for a study building is presented. The purpose of the work is to support the development of a combined indoor-outdoor hazard prediction tool, which links the CONTAM multizone building simulation tool with outdoor dispersion models. The study building, representing a large office block of a simple rectangular geometry under natural ventilation, was based on a real building used in the Joint Urban 2003 experiment. A total of 1600 indoor model flow simulations were made, driven by 100 meteorological conditionsmore » which provided a wide range of building surface pressures. These pressures were applied at four levels of resolution to four different building configurations with varying numbers of internal zones and indoor and outdoor flow paths. Analysis of the results suggests that surface pressures and flow paths across the envelope should be specified at a resolution consistent with the dimensions of the smallest volume of interest, to ensure that appropriate outputs are obtained.« less

  15. Nonlinear Contact Effects in Staggered Thin-Film Transistors

    NASA Astrophysics Data System (ADS)

    Fischer, Axel; Zündorf, Hilke; Kaschura, Felix; Widmer, Johannes; Leo, Karl; Kraft, Ulrike; Klauk, Hagen

    2017-11-01

    The static and dynamic electrical characteristics of thin-film transistors (TFTs) are often limited by the parasitic contact resistances, especially for TFTs with a small channel length. For the smallest possible contact resistance, the staggered device architecture has a general advantage over the coplanar architecture of a larger injection area. Since the charge transport occurs over an extended area, it is inherently more difficult to develop an accurate analytical device model for staggered TFTs. Most analytical models for staggered TFTs, therefore, assume that the contact resistance is linear, even though this is commonly accepted not to be the case. Here, we introduce a semiphenomenological approach to accurately fit experimental data based on a highly discretized equivalent network circuit explicitly taking into account the inherent nonlinearity of the contact resistance. The model allows us to investigate the influence of nonlinear contact resistances on the static and dynamic performance of staggered TFTs for different contact layouts with a relatively short computation time. The precise extraction of device parameters enables us to calculate the transistor behavior as well as the potential for optimization in real circuits.

  16. [The smallest toy dog from the Roman empire].

    PubMed

    Boessneck, J

    1989-01-01

    This study deals with osseous remains of the smallest breed of dogs found in deposits related to the Roman Imperial period. The bone material has been collected at the Colonia Ulpia Traiana near Xanten on the Rhine. It has been observed that the bones match in size with the smallest breeds of dogs known today.

  17. Analysis of Intergrade Variables In The Fuzzy C-Means And Improved Algorithm Cat Swarm Optimization(FCM-ISO) In Search Segmentation

    NASA Astrophysics Data System (ADS)

    Saragih, Jepronel; Salim Sitompul, Opim; Situmorang, Zakaria

    2017-12-01

    One of the techniques known in Data Mining namely clustering. Image segmentation process does not always represent the actual image which is caused by a combination of algorithms as long as it has not been able to obtain optimal cluster centers. In this research will search for the smallest error with the counting result of a Fuzzy C Means process optimized with Cat swam Algorithm Optimization that has been developed by adding the weight of the energy in the process of Tracing Mode.So with the parameter can be determined the most optimal cluster centers and most closely with the data will be made the cluster. Weigh inertia in this research, namely: (0.1), (0.2), (0.3), (0.4), (0.5), (0.6), (0.7), (0.8) and (0.9). Then compare the results of each variable values inersia (W) which is different and taken the smallest results. Of this weighting analysis process can acquire the right produce inertia variable cost function the smallest.

  18. Nozzle geometry for organic vapor jet printing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Forrest, Stephen R.; McGraw, Gregory

    A first device is provided. The device includes a print head. The print head further includes a first nozzle hermetically sealed to a first source of gas. The first nozzle has an aperture having a smallest dimension of 0.5 to 500 microns in a direction perpendicular to a flow direction of the first nozzle. At a distance from the aperture into the first nozzle that is 5 times the smallest dimension of the aperture of the first nozzle, the smallest dimension perpendicular to the flow direction is at least twice the smallest dimension of the aperture of the first nozzle.

  19. Nozzle geometry for organic vapor jet printing

    DOEpatents

    Forrest, Stephen R; McGraw, Gregory

    2015-01-13

    A first device is provided. The device includes a print head. The print head further includes a first nozzle hermetically sealed to a first source of gas. The first nozzle has an aperture having a smallest dimension of 0.5 to 500 microns in a direction perpendicular to a flow direction of the first nozzle. At a distance from the aperture into the first nozzle that is 5 times the smallest dimension of the aperture of the first nozzle, the smallest dimension perpendicular to the flow direction is at least twice the smallest dimension of the aperture of the first nozzle.

  20. Consumption of a High Quantity and a Wide Variety of Vegetables Are Predicted by Different Food Choice Motives in Older Adults from France, Italy and the UK.

    PubMed

    Appleton, Katherine M; Dinnella, Caterina; Spinelli, Sara; Morizet, David; Saulais, Laure; Hemingway, Ann; Monteleone, Erminio; Depezay, Laurence; Perez-Cueto, Frederico J A; Hartwell, Heather

    2017-08-23

    Consumption of a high quantity and wide variety of vegetables is currently recommended for health. Dietary variety can be low, however, particularly for older adults. This study investigated the affective factors associated with the quantity and variety of vegetables consumed by older adults in France, Italy and the UK. Adults aged 65 years plus completed questionnaires on self-reported vegetable intake (quantity and variety), liking for vegetables, attitudes towards intake, and demographic variables. In 497 older adults (France, n = 187, Italy, n = 152, UK, n = 158), higher quantities of vegetables consumed were associated with a higher age, affluence score and liking for vegetables, and a lower importance in consumption of familiarity (smallest β = 0.11, p = 0.03). Greater variety was associated with a higher liking and importance of health benefits, and a lower importance of familiarity (smallest β = -0.11, p < 0.01). Higher quantity and variety combined (quantity × variety) was associated with a higher age, liking and importance of health benefits, and a lower importance of familiarity (smallest β = 0.14, p = 0.02). Country-specific effects were also found (smallest β = 0.20, p < 0.01). These findings demonstrate a role for liking and a lower concern for eating familiar foods in vegetable consumption, and a particular role for concern for health benefits in the consumption of a greater variety of vegetables.

  1. Consumption of a High Quantity and a Wide Variety of Vegetables Are Predicted by Different Food Choice Motives in Older Adults from France, Italy and the UK

    PubMed Central

    Dinnella, Caterina; Spinelli, Sara; Morizet, David; Saulais, Laure; Hemingway, Ann; Monteleone, Erminio; Depezay, Laurence; Perez-Cueto, Federico J. A.; Hartwell, Heather

    2017-01-01

    Background: Consumption of a high quantity and wide variety of vegetables is currently recommended for health. Dietary variety can be low, however, particularly for older adults. This study investigated the affective factors associated with the quantity and variety of vegetables consumed by older adults in France, Italy and the UK. Methods: Adults aged 65 years plus completed questionnaires on self-reported vegetable intake (quantity and variety), liking for vegetables, attitudes towards intake, and demographic variables. Results: In 497 older adults (France, n = 187, Italy, n = 152, UK, n = 158), higher quantities of vegetables consumed were associated with a higher age, affluence score and liking for vegetables, and a lower importance in consumption of familiarity (smallest β = 0.11, p = 0.03). Greater variety was associated with a higher liking and importance of health benefits, and a lower importance of familiarity (smallest β = −0.11, p < 0.01). Higher quantity and variety combined (quantity × variety) was associated with a higher age, liking and importance of health benefits, and a lower importance of familiarity (smallest β = 0.14, p = 0.02). Country-specific effects were also found (smallest β = 0.20, p < 0.01). Conclusions: These findings demonstrate a role for liking and a lower concern for eating familiar foods in vegetable consumption, and a particular role for concern for health benefits in the consumption of a greater variety of vegetables. PMID:28832549

  2. Real-time PCR to quantify composition of arbuscular mycorrhizal fungal communities--marker design, verification, calibration and field validation.

    PubMed

    Thonar, C; Erb, A; Jansa, J

    2012-03-01

    Quantitative real-time PCR (qPCR) is slowly becoming established as a tool to quantify abundance of different arbuscular mycorrhizal fungal (AMF) taxa in roots and in soil. Here, we describe the development and field validation of qPCR markers (i.e. primers with associated hydrolysis probes), targeting taxon-specific motifs in the nuclear large ribosomal subunit RNA genes. Design of such markers is complicated by the multinuclear and multigenomic cellular organization of these fungi and the high DNA sequence diversity within the smallest biologically relevant units (i.e. single-spore isolates). These limitations are further compounded by inefficient biomass production of these fungi, resulting in limited availability of pure genomic DNA (gDNA) of well-defined isolates for cross-specificity testing of the markers. Here we demonstrate, using a number of AMF isolates, the possibility to establish stringent qPCR running conditions allowing quantification of phylogenetically disjunctive AMF taxa. Further, we show that these markers can more generally be used to quantify abundance (i.e. number of target gene copies or amount of gDNA) of what is usually considered the level of AMF species, regardless of the isolate identities. We also illustrate the range of variation within qPCR signal strength across different AMF taxa with respect to the detected number of gene copies per unit amount of gDNA. This information is paramount for interpretation of the qPCR analyses of field samples. Finally, the field validation of these markers confirmed their potential to assess composition of field AMF communities and monitor the changes owing to agricultural practices such as soil tillage. © 2011 Blackwell Publishing Ltd.

  3. Study on the mapping of dark matter clustering from real space to redshift space

    NASA Astrophysics Data System (ADS)

    Zheng, Yi; Song, Yong-Seon

    2016-08-01

    The mapping of dark matter clustering from real space to redshift space introduces the anisotropic property to the measured density power spectrum in redshift space, known as the redshift space distortion effect. The mapping formula is intrinsically non-linear, which is complicated by the higher order polynomials due to indefinite cross correlations between the density and velocity fields, and the Finger-of-God effect due to the randomness of the peculiar velocity field. Whilst the full higher order polynomials remain unknown, the other systematics can be controlled consistently within the same order truncation in the expansion of the mapping formula, as shown in this paper. The systematic due to the unknown non-linear density and velocity fields is removed by separately measuring all terms in the expansion directly using simulations. The uncertainty caused by the velocity randomness is controlled by splitting the FoG term into two pieces, 1) the ``one-point" FoG term being independent of the separation vector between two different points, and 2) the ``correlated" FoG term appearing as an indefinite polynomials which is expanded in the same order as all other perturbative polynomials. Using 100 realizations of simulations, we find that the Gaussian FoG function with only one scale-independent free parameter works quite well, and that our new mapping formulation accurately reproduces the observed 2-dimensional density power spectrum in redshift space at the smallest scales by far, up to k~ 0.2 Mpc-1, considering the resolution of future experiments.

  4. Maximizing synchronizability of duplex networks

    NASA Astrophysics Data System (ADS)

    Wei, Xiang; Emenheiser, Jeffrey; Wu, Xiaoqun; Lu, Jun-an; D'Souza, Raissa M.

    2018-01-01

    We study the synchronizability of duplex networks formed by two randomly generated network layers with different patterns of interlayer node connections. According to the master stability function, we use the smallest nonzero eigenvalue and the eigenratio between the largest and the second smallest eigenvalues of supra-Laplacian matrices to characterize synchronizability on various duplexes. We find that the interlayer linking weight and linking fraction have a profound impact on synchronizability of duplex networks. The increasingly large inter-layer coupling weight is found to cause either decreasing or constant synchronizability for different classes of network dynamics. In addition, negative node degree correlation across interlayer links outperforms positive degree correlation when most interlayer links are present. The reverse is true when a few interlayer links are present. The numerical results and understanding based on these representative duplex networks are illustrative and instructive for building insights into maximizing synchronizability of more realistic multiplex networks.

  5. Using a dry electrode EEG device during balance tasks in healthy young-adult males: Test-retest reliability analysis.

    PubMed

    Collado-Mateo, Daniel; Adsuar, Jose C; Olivares, Pedro R; Cano-Plasencia, Ricardo; Gusi, Narcis

    2015-01-01

    The analysis of brain activity during balance is an important topic in different fields of science. Given that all measurements involve an error that is caused by different agents, like the instrument, the researcher, or the natural human variability, a test-retest reliability evaluation of the electroencephalographic assessment is a needed starting point. However, there is a lack of information about the reliability of electroencephalographic measurements, especially in a new wireless device with dry electrodes. The current study aims to analyze the reliability of electroencephalographic measurements from a wireless device using dry electrodes during two different balance tests. Seventeen healthy male volunteers performed two different static balance tasks on a Biodex Balance Platform: (a) with two feet on the platform and (b) with one foot on the platform. Electroencephalographic data was recorded using Enobio (Neuroelectrics). The mean power spectrum of the alpha band of the central and frontal channels was calculated. Relative and absolute indices of reliability were also calculated. In general terms, the intraclass correlation coefficient (ICC) values of all the assessed channels can be classified as excellent (>0.90). The percentage standard error of measurement oscillated from 0.54% to 1.02% and the percentage smallest real difference ranged from 1.50% to 2.82%. Electroencephalographic assessment through an Enobio device during balance tasks has an excellent reliability. However, its utility was not demonstrated because responsiveness was not assessed.

  6. Kernel Equating Under the Non-Equivalent Groups With Covariates Design

    PubMed Central

    Bränberg, Kenny

    2015-01-01

    When equating two tests, the traditional approach is to use common test takers and/or common items. Here, the idea is to use variables correlated with the test scores (e.g., school grades and other test scores) as a substitute for common items in a non-equivalent groups with covariates (NEC) design. This is performed in the framework of kernel equating and with an extension of the method developed for post-stratification equating in the non-equivalent groups with anchor test design. Real data from a college admissions test were used to illustrate the use of the design. The equated scores from the NEC design were compared with equated scores from the equivalent group (EG) design, that is, equating with no covariates as well as with equated scores when a constructed anchor test was used. The results indicate that the NEC design can produce lower standard errors compared with an EG design. When covariates were used together with an anchor test, the smallest standard errors were obtained over a large range of test scores. The results obtained, that an EG design equating can be improved by adjusting for differences in test score distributions caused by differences in the distribution of covariates, are useful in practice because not all standardized tests have anchor tests. PMID:29881012

  7. The dynamical environment of asteroid 21 Lutetia according to different internal models

    NASA Astrophysics Data System (ADS)

    Aljbaae, S.; Chanut, T. G. G.; Carruba, V.; Souchay, J.; Prado, A. F. B. A.; Amarante, A.

    2017-01-01

    One of the most accurate models currently used to represent the gravity field of irregular bodies is the polyhedral approach. In this model, the mass of the body is assumed to be homogeneous, which may not be true for a real object. The main goal of the this paper is to study the dynamical effects induced by three different internal structures (uniform, three- and four-layered) of asteroid (21) Lutetia, an object that recent results from space probe suggest being at least partially differentiated. The Mascon gravity approach used in the this work consists of dividing each tetrahedron into eight parts to calculate the gravitational field around the asteroid. The zero-velocity curves show that the greatest displacement of the equilibrium points occurs in the position of the E4 point for the four-layered structure and the smallest one occurs in the position of the E3 point for the three-layered structure. Moreover, stability against impact shows that the planar limit gets slightly closer to the body with the four-layered structure. We then investigated the stability of orbital motion in the equatorial plane of (21) Lutetia and propose numerical stability criteria to map the region of stable motions. Layered structures could stabilize orbits that were unstable in the homogeneous model.

  8. Kernel Equating Under the Non-Equivalent Groups With Covariates Design.

    PubMed

    Wiberg, Marie; Bränberg, Kenny

    2015-07-01

    When equating two tests, the traditional approach is to use common test takers and/or common items. Here, the idea is to use variables correlated with the test scores (e.g., school grades and other test scores) as a substitute for common items in a non-equivalent groups with covariates (NEC) design. This is performed in the framework of kernel equating and with an extension of the method developed for post-stratification equating in the non-equivalent groups with anchor test design. Real data from a college admissions test were used to illustrate the use of the design. The equated scores from the NEC design were compared with equated scores from the equivalent group (EG) design, that is, equating with no covariates as well as with equated scores when a constructed anchor test was used. The results indicate that the NEC design can produce lower standard errors compared with an EG design. When covariates were used together with an anchor test, the smallest standard errors were obtained over a large range of test scores. The results obtained, that an EG design equating can be improved by adjusting for differences in test score distributions caused by differences in the distribution of covariates, are useful in practice because not all standardized tests have anchor tests.

  9. The Representation of Morphemes in the Russian Lexicon

    ERIC Educational Resources Information Center

    Antic, Eugenia

    2010-01-01

    Different morphological theories assign different status to parts of words, roots and affixes. Models range from accepting both bound roots and affixes to only assigning unit status to standalone words. Some questions that interest researchers are (1) What are the smallest morphological units, words or word parts? (2) How does frequency affect…

  10. Heterogeneous gene expression and functional activity of ryanodine receptors in resistance and conduit pulmonary as well as mesenteric artery smooth muscle cells.

    PubMed

    Zheng, Yun-Min; Wang, Qing-Song; Liu, Qing-Hua; Rathore, Rakesh; Yadav, Vishal; Wang, Yong-Xiao

    2008-01-01

    Hypoxia causes heterogeneous contractile responses in resistance and conduit pulmonary as well as systemic (mesenteric) artery smooth muscle cells (RPASMCs, CPASMCs and MASMCs), but the underlying mechanisms are largely unknown. In this study, we aimed to investigate whether the gene expression and functional activity of ryanodine receptors (RyRs) would be different in these 3 cell types. RyR mRNA expression, Ca(2+) sparks and [Ca(2+)](i) were measured by real-time quantitative RT-PCR, laser scanning confocal microscopy and wide-field fluorescence microscopy, respectively. All 3 RyR subtype (RyR1, RyR2 and RyR3) mRNAs are expressed in RPASMCs, CPASMCs and MASMCs, but their expression levels are different. Spontaneous Ca(2+) sparks (functional events of RyRs) show distinct frequency, amplitude, duration, size and kinetics in these 3 cell types. Similarly, activation of RyRs by caffeine, 4-chloro-m-cresol or high K(+) induces differential Ca(2+) release. Moreover, hypoxia-induced increase in [Ca(2+)](i) is largest in MASMCs relative to CPSAMCs and smallest in RPASMCs. This study provides comprehensive evidence that RyRs are heterogeneous in gene expression and functional activity in RPASMCs, CPASMCs and MASMCs, which may contribute to the diversity of excitation-contraction coupling and hypoxic Ca(2+) responses in different vascular smooth muscle cells. Copyright 2008 S. Karger AG, Basel.

  11. Differential expression analysis for RNAseq using Poisson mixed models.

    PubMed

    Sun, Shiquan; Hood, Michelle; Scott, Laura; Peng, Qinke; Mukherjee, Sayan; Tung, Jenny; Zhou, Xiang

    2017-06-20

    Identifying differentially expressed (DE) genes from RNA sequencing (RNAseq) studies is among the most common analyses in genomics. However, RNAseq DE analysis presents several statistical and computational challenges, including over-dispersed read counts and, in some settings, sample non-independence. Previous count-based methods rely on simple hierarchical Poisson models (e.g. negative binomial) to model independent over-dispersion, but do not account for sample non-independence due to relatedness, population structure and/or hidden confounders. Here, we present a Poisson mixed model with two random effects terms that account for both independent over-dispersion and sample non-independence. We also develop a scalable sampling-based inference algorithm using a latent variable representation of the Poisson distribution. With simulations, we show that our method properly controls for type I error and is generally more powerful than other widely used approaches, except in small samples (n <15) with other unfavorable properties (e.g. small effect sizes). We also apply our method to three real datasets that contain related individuals, population stratification or hidden confounders. Our results show that our method increases power in all three data compared to other approaches, though the power gain is smallest in the smallest sample (n = 6). Our method is implemented in MACAU, freely available at www.xzlab.org/software.html. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  12. A new method for assessing the accuracy of full arch impressions in patients.

    PubMed

    Kuhr, F; Schmidt, A; Rehmann, P; Wöstmann, B

    2016-12-01

    To evaluate a new method of measuring the real deviation (trueness) of full arch impressions intraorally and to investigate the trueness of digital full arch impressions in comparison to a conventional impression procedure in clinical use. Four metal spheres were fixed with composite using a metal application aid to the lower teeth of 50 test subjects as reference structures. One conventional impression (Impregum Penta Soft) with subsequent type-IV gypsum model casting (CI) and three different digital impressions were performed in the lower jaw of each test person with the following intraoral scanners: Sirona CEREC Omnicam (OC), 3M True Definition (TD), Heraeus Cara TRIOS (cT). The digital and conventional (gypsum) models were analyzed relative to the spheres. Linear distance and angle measurements between the spheres, as well as digital superimpositions of the spheres with the reference data set were executed. With regard to the distance measurements, CI showed the smallest deviations followed by intraoral scanners TD, cT and OC. A digital superimposition procedure yielded the same order for the outcomes: CI (15±4μm), TD (23±9μm), cT (37±14μm), OC (214±38μm). Angle measurements revealed the smallest deviation for TD (0.06°±0,07°) followed by CI (0.07°±0.07°), cT (0.13°±0.15°) and OC (0.28°±0.21°). The new measuring method is suitable for measuring the dimensional accuracy of full arch impressions intraorally. CI is still significantly more accurate than full arch scans with intraoral scanners in clinical use. Conventional full arch impressions with polyether impression materials are still more accurate than full arch digital impressions. Digital impression systems using powder application and active wavefront sampling technology achieve the most accurate results in comparison to other intraoral scanning systems (DRKS-ID: DRKS00009360, German Clinical Trials Register). Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Dominating Scale-Free Networks Using Generalized Probabilistic Methods

    PubMed Central

    Molnár,, F.; Derzsy, N.; Czabarka, É.; Székely, L.; Szymanski, B. K.; Korniss, G.

    2014-01-01

    We study ensemble-based graph-theoretical methods aiming to approximate the size of the minimum dominating set (MDS) in scale-free networks. We analyze both analytical upper bounds of dominating sets and numerical realizations for applications. We propose two novel probabilistic dominating set selection strategies that are applicable to heterogeneous networks. One of them obtains the smallest probabilistic dominating set and also outperforms the deterministic degree-ranked method. We show that a degree-dependent probabilistic selection method becomes optimal in its deterministic limit. In addition, we also find the precise limit where selecting high-degree nodes exclusively becomes inefficient for network domination. We validate our results on several real-world networks, and provide highly accurate analytical estimates for our methods. PMID:25200937

  14. Improving the performances of autofocus based on adaptive retina-like sampling model

    NASA Astrophysics Data System (ADS)

    Hao, Qun; Xiao, Yuqing; Cao, Jie; Cheng, Yang; Sun, Ce

    2018-03-01

    An adaptive retina-like sampling model (ARSM) is proposed to balance autofocusing accuracy and efficiency. Based on the model, we carry out comparative experiments between the proposed method and the traditional method in terms of accuracy, the full width of the half maxima (FWHM) and time consumption. Results show that the performances of our method are better than that of the traditional method. Meanwhile, typical autofocus functions, including sum-modified-Laplacian (SML), Laplacian (LAP), Midfrequency-DCT (MDCT) and Absolute Tenengrad (ATEN) are compared through comparative experiments. The smallest FWHM is obtained by the use of LAP, which is more suitable for evaluating accuracy than other autofocus functions. The autofocus function of MDCT is most suitable to evaluate the real-time ability.

  15. Observation and characterization of the smallest borospherene, B{sub 28}{sup −} and B{sub 28}

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Ying-Jin; Chen, Qiang; You, Xue-Rui

    2016-02-14

    Free-standing boron nanocages or borospherenes have been observed recently for B{sub 40}{sup −} and B{sub 40}. There is evidence that a family of borospherenes may exist. However, the smallest borospherene is still not known. Here, we report experimental and computational evidence of a seashell-like borospherene cage for B{sub 28}{sup −} and B{sub 28}. Photoelectron spectrum of B{sub 28}{sup −} indicated contributions from different isomers. Theoretical calculations showed that the seashell-like B{sub 28}{sup −} borospherene is competing for the global minimum with a planar isomer and it is shown to be present in the cluster beam, contributing to the observed photoelectronmore » spectrum. The seashell structure is found to be the global minimum for neutral B{sub 28} and the B{sub 28}{sup −} cage represents the smallest borospherene observed to date. It is composed of two triangular close-packed B{sub 15} sheets, interconnected via the three corners by sharing two boron atoms. The B{sub 28} borospherene was found to obey the 2(n + 1){sup 2} electron-counting rule for spherical aromaticity.« less

  16. In vivo real-time fluorescence visualization and brain-targeting mechanisms of lipid nanocarriers with different fatty ester:oil ratios.

    PubMed

    Wen, Chih-Jen; Yen, Tzu-Chen; Al-Suwayeh, Saleh A; Chang, Hui-Wen; Fang, Jia-You

    2011-11-01

    The objective of the present work was to investigate the influence of the inner cores of lipid nanocarriers on the efficiency of brain targeting. Cetyl palmitate and squalene were respectively chosen as the solid lipid and liquid oil in the inner phase of the nanocarriers. Nanoparticulate systems with different cetyl palmitate/squalene ratios were compared by evaluating the size, zeta potential, molecular environment, and mobility of lipids in the systems. The particulate diameter ranged from 190 to 210 nm, with systems containing 100% cetyl palmitate in the matrix (solid lipid nanoparticles [SLN]) showing the smallest size, followed by systems with both cetyl palmitate and squalene (nanostructured lipid carriers [NLC]) and with 100% squalene (lipid emulsions [LE]). A cationic surfactant, Forestall, was used to produce a positive surface charge of 40-55 mW. The in vitro release was evaluated using various dyes located in different phases of the nanocarriers. The release of sulforhodamine B occurred in a sustained manner from the shell of the nanocarriers. The in vivo brain distribution of lipid nanosystems after an intravenous injection into rats was monitored by a real-time fluorescence imaging system. LE showed higher brain accumulation than SLN and NLC. NLC only exhibited a slightly higher brain accumulation compared with the aqueous control. Incorporation of sulforhodamine B into LE could prolong its retention in the brain from 20 to 50 min. The results were further confirmed by imaging the entire brain and brain slices. The specific association of lipid nanocarriers with rat brain endothelial cells (bEnd3) was demonstrated using fluorescence microscopy. The cellular uptake of LE and SLN was higher compared with NLC and the aqueous control. LE were observed to be internalized by cells through caveola-mediated and macropinocytotic energy-dependent endocytosis. The experimental profiles indicated that LE with moderate additives are a promising brain-targeting nanocarrier. The composition of the lipid matrix played a significant role in delivering compounds to the brain.

  17. Meat and masculinity among young Chinese, Turkish and Dutch adults in the Netherlands.

    PubMed

    Schösler, Hanna; de Boer, Joop; Boersema, Jan J; Aiking, Harry

    2015-06-01

    The achievement of sustainability and health objectives in Western countries requires a transition to a less meat-based diet. This article investigates whether the alleged link between meat consumption and particular framings of masculinity, which emphasize that 'real men' eat meat, may stand in the way of achieving these objectives. From a theoretical perspective, it was assumed that the meat-masculinity link is not invariant but dependent on the cultural context, including ethnicity. In order to examine the link in different contexts, we analyzed whether meat-related gender differences varied across ethnic groups, using samples of young second generation Chinese Dutch, Turkish Dutch and native Dutch adults (aged 18-35) in the Netherlands. The Turkish group was the most traditional; it showed the largest gender differences and the strongest meat-masculinity link. In contrast, the native group showed the smallest gender differences and the weakest meat-masculinity link. The findings suggest that the combination of traditional framings of masculinity and the Western type of food environment where meat is abundant and cheap is bound to seriously hamper a transition to a less meat-based diet. In contrast, less traditional framings of masculinity seem to contribute to more healthy food preferences with respect to meat. It was concluded that cultural factors related to gender and ethnic diversity can play harmful and beneficial roles for achieving sustainability and health objectives. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Reproducibility of 3D kinematics and surface electromyography measurements of mastication.

    PubMed

    Remijn, Lianne; Groen, Brenda E; Speyer, Renée; van Limbeek, Jacques; Nijhuis-van der Sanden, Maria W G

    2016-03-01

    The aim of this study was to determine the measurement reproducibility for a procedure evaluating the mastication process and to estimate the smallest detectable differences of 3D kinematic and surface electromyography (sEMG) variables. Kinematics of mandible movements and sEMG activity of the masticatory muscles were obtained over two sessions with four conditions: two food textures (biscuit and bread) of two sizes (small and large). Twelve healthy adults (mean age 29.1 years) completed the study. The second to the fifth chewing cycle of 5 bites were used for analyses. The reproducibility per outcome variable was calculated with an intraclass correlation coefficient (ICC) and a Bland-Altman analysis was applied to determine the standard error of measurement relative error of measurement and smallest detectable differences of all variables. ICCs ranged from 0.71 to 0.98 for all outcome variables. The outcome variables consisted of four bite and fourteen chewing cycle variables. The relative standard error of measurement of the bite variables was up to 17.3% for 'time-to-swallow', 'time-to-transport' and 'number of chewing cycles', but ranged from 31.5% to 57.0% for 'change of chewing side'. The relative standard error of measurement ranged from 4.1% to 24.7% for chewing cycle variables and was smaller for kinematic variables than sEMG variables. In general, measurements obtained with 3D kinematics and sEMG are reproducible techniques to assess the mastication process. The duration of the chewing cycle and frequency of chewing were the best reproducible measurements. Change of chewing side could not be reproduced. The published measurement error and smallest detectable differences will aid the interpretation of the results of future clinical studies using the same study variables. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Refinements to Atlantic basin seasonal hurricane prediction from 1 December

    NASA Astrophysics Data System (ADS)

    Klotzbach, Philip J.

    2008-09-01

    Atlantic basin seasonal hurricane predictions have been issued by the Tropical Meteorology Project at Colorado State University since 1984, with early December forecasts being issued every year since early December 1991. These forecasts have yet to show real-time forecast skill, despite several statistical models that have shown considerable hindcast skill. In an effort to improve both hindcast skill and hopefully real-time forecast skill, a modified forecast scheme has been developed using data from 1950 to 2007. Predictors were selected based upon how much variance was explained over the 1950-1989 subperiod. These predictors were then required to explain similar amounts of variance over a latter subperiod from 1990 to 2007. Similar amounts of skill were demonstrated for each of the three predictors selected over the 1950-1989 period, the 1990-2007 period, and the full 1950-2007 period. In addition, significant correlations between individual predictors and physical features known to affect hurricanes during the following August-October (i.e., tropical Atlantic wind shear and sea level pressure changes, ENSO phase changes) were obtained. This scheme uses a new methodology where hindcasts were obtained using linear regression and then ranked to generate final hindcast values. Fifty-four percent of the variance was explained for seasonal Net Tropical Cyclone (NTC) activity over the 1950-2007 period. These hindcasts show considerable differences in landfalling U.S. tropical cyclones, especially for the Florida Peninsula and East Coast. Seven major hurricanes made Florida Peninsula and East Coast landfall during the top 15 largest NTC hindcasts compared with only two major hurricane landfalls in the bottom 15 smallest NTC hindcasts.

  20. A study of longitudinal tumor motion in helical tomotherapy using a cylindrical phantom

    PubMed Central

    Klein, Michael; Gaede, Stewart

    2013-01-01

    Tumor motion during radiation treatment on a helical tomotherapy unit may create problems due to interplay with motion of the multileaf collimator, gantry rotation, and patient couch translation through the gantry. This study evaluated this interplay effect for typical clinical parameters using a cylindrical phantom consisting of 1386 diode detectors placed on a respiratory motion platform. All combinations of radiation field widths (1, 2.5, and 5 cm) and gantry rotation periods (16, 30, and 60 s) were considered for sinusoidal motions with a period of 4 s and amplitudes of 5, 6, 7, 8, 9, and 10 mm, as well as real patient breathing pattern. Gamma comparisons with 2% dose difference and 2 mm distance to agreement and dose profiles were used for evaluation. The required motion margins were determined for each set of parameters. The required margin size increased with decreasing field width and increasing tumor motion amplitude, but was not affected by rotation period. The plans with the smallest field width of 1 cm have required motion margins approximately equal to the amplitude of motion (±25%), while those with the largest field width of 5 cm had required motion margins approximately equal to 20% of the motion amplitude (±20%). For tumor motion amplitudes below 6 mm and field widths above 1 cm, the required additional motion margins were very small, at a maximum of 2.5 mm for sinusoidal breathing patterns and 1.2 mm for the real patient breathing pattern. PACS numbers: 87.55.km, 87.55.Qr, 87.56.Fc

  1. Study on the mapping of dark matter clustering from real space to redshift space

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zheng, Yi; Song, Yong-Seon, E-mail: yizheng@kasi.re.kr, E-mail: ysong@kasi.re.kr

    The mapping of dark matter clustering from real space to redshift space introduces the anisotropic property to the measured density power spectrum in redshift space, known as the redshift space distortion effect. The mapping formula is intrinsically non-linear, which is complicated by the higher order polynomials due to indefinite cross correlations between the density and velocity fields, and the Finger-of-God effect due to the randomness of the peculiar velocity field. Whilst the full higher order polynomials remain unknown, the other systematics can be controlled consistently within the same order truncation in the expansion of the mapping formula, as shown inmore » this paper. The systematic due to the unknown non-linear density and velocity fields is removed by separately measuring all terms in the expansion directly using simulations. The uncertainty caused by the velocity randomness is controlled by splitting the FoG term into two pieces, 1) the ''one-point' FoG term being independent of the separation vector between two different points, and 2) the ''correlated' FoG term appearing as an indefinite polynomials which is expanded in the same order as all other perturbative polynomials. Using 100 realizations of simulations, we find that the Gaussian FoG function with only one scale-independent free parameter works quite well, and that our new mapping formulation accurately reproduces the observed 2-dimensional density power spectrum in redshift space at the smallest scales by far, up to k ∼ 0.2 Mpc{sup -1}, considering the resolution of future experiments.« less

  2. Registration uncertainties between 3D cone beam computed tomography and different reference CT datasets in lung stereotactic body radiation therapy.

    PubMed

    Oechsner, Markus; Chizzali, Barbara; Devecka, Michal; Combs, Stephanie Elisabeth; Wilkens, Jan Jakob; Duma, Marciana Nona

    2016-10-26

    The aim of this study was to analyze differences in couch shifts (setup errors) resulting from image registration of different CT datasets with free breathing cone beam CTs (FB-CBCT). As well automatic as manual image registrations were performed and registration results were correlated to tumor characteristics. FB-CBCT image registration was performed for 49 patients with lung lesions using slow planning CT (PCT), average intensity projection (AIP), maximum intensity projection (MIP) and mid-ventilation CTs (MidV) as reference images. Both, automatic and manual image registrations were applied. Shift differences were evaluated between the registered CT datasets for automatic and manual registration, respectively. Furthermore, differences between automatic and manual registration were analyzed for the same CT datasets. The registration results were statistically analyzed and correlated to tumor characteristics (3D tumor motion, tumor volume, superior-inferior (SI) distance, tumor environment). Median 3D shift differences over all patients were between 0.5 mm (AIPvsMIP) and 1.9 mm (MIPvsPCT and MidVvsPCT) for the automatic registration and between 1.8 mm (AIPvsPCT) and 2.8 mm (MIPvsPCT and MidVvsPCT) for the manual registration. For some patients, large shift differences (>5.0 mm) were found (maximum 10.5 mm, automatic registration). Comparing automatic vs manual registrations for the same reference CTs, ∆AIP achieved the smallest (1.1 mm) and ∆MIP the largest (1.9 mm) median 3D shift differences. The standard deviation (variability) for the 3D shift differences was also the smallest for ∆AIP (1.1 mm). Significant correlations (p < 0.01) between 3D shift difference and 3D tumor motion (AIPvsMIP, MIPvsMidV) and SI distance (AIPvsMIP) (automatic) and also for 3D tumor motion (∆PCT, ∆MidV; automatic vs manual) were found. Using different CT datasets for image registration with FB-CBCTs can result in different 3D couch shifts. Manual registrations achieved partly different 3D shifts than automatic registrations. AIP CTs yielded the smallest shift differences and might be the most appropriate CT dataset for registration with 3D FB-CBCTs.

  3. Reproducibility of isometric shoulder protraction and retraction strength measurements in normal subjects and individuals with winged scapula.

    PubMed

    Oh, Jae-Seop; Kang, Min-Hyeok; Dvir, Zeevi

    2016-11-01

    The strength of the shoulder protractors and retractors may be compromised in individuals with winged scapula (IwWS). However, no standard approach to measuring the strength of these muscles has been described. The aim of this study was to study the intra-rater and inter-rater reproducibility of a fixed-base isometric dynamometer and to describe cutoff scores for clinically meaningful change for protraction and retraction isometric strength. Twice during a week, 20 normal subjects and 20 IwWS were tested by 2 independent raters. IwWS were significantly weaker (P < .001) than control subjects in their protraction and retraction isometric strength. Excellent intra-rater and inter-rater correlations were obtained in most combinations, leading to low cutoff scores for meaningful change expressed in terms of the smallest real difference. When it is properly used, the technique described in this paper is recommended as an effective clinical tool for the quantitative assessment of protraction and retraction isometric strength, both for status determination and for monitoring of change in IwWS during and after rehabilitation. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  4. Segmentation of human face using gradient-based approach

    NASA Astrophysics Data System (ADS)

    Baskan, Selin; Bulut, M. Mete; Atalay, Volkan

    2001-04-01

    This paper describes a method for automatic segmentation of facial features such as eyebrows, eyes, nose, mouth and ears in color images. This work is an initial step for wide range of applications based on feature-based approaches, such as face recognition, lip-reading, gender estimation, facial expression analysis, etc. Human face can be characterized by its skin color and nearly elliptical shape. For this purpose, face detection is performed using color and shape information. Uniform illumination is assumed. No restrictions on glasses, make-up, beard, etc. are imposed. Facial features are extracted using the vertically and horizontally oriented gradient projections. The gradient of a minimum with respect to its neighbor maxima gives the boundaries of a facial feature. Each facial feature has a different horizontal characteristic. These characteristics are derived by extensive experimentation with many face images. Using fuzzy set theory, the similarity between the candidate and the feature characteristic under consideration is calculated. Gradient-based method is accompanied by the anthropometrical information, for robustness. Ear detection is performed using contour-based shape descriptors. This method detects the facial features and circumscribes each facial feature with the smallest rectangle possible. AR database is used for testing. The developed method is also suitable for real-time systems.

  5. Compressive sensing scalp EEG signals: implementations and practical performance.

    PubMed

    Abdulghani, Amir M; Casson, Alexander J; Rodriguez-Villegas, Esther

    2012-11-01

    Highly miniaturised, wearable computing and communication systems allow unobtrusive, convenient and long term monitoring of a range of physiological parameters. For long term operation from the physically smallest batteries, the average power consumption of a wearable device must be very low. It is well known that the overall power consumption of these devices can be reduced by the inclusion of low power consumption, real-time compression of the raw physiological data in the wearable device itself. Compressive sensing is a new paradigm for providing data compression: it has shown significant promise in fields such as MRI; and is potentially suitable for use in wearable computing systems as the compression process required in the wearable device has a low computational complexity. However, the practical performance very much depends on the characteristics of the signal being sensed. As such the utility of the technique cannot be extrapolated from one application to another. Long term electroencephalography (EEG) is a fundamental tool for the investigation of neurological disorders and is increasingly used in many non-medical applications, such as brain-computer interfaces. This article investigates in detail the practical performance of different implementations of the compressive sensing theory when applied to scalp EEG signals.

  6. Validity and test-retest reliability of the six-spot step test in persons after stroke.

    PubMed

    Arvidsson Lindvall, Mialinn; Anderzén-Carlsson, Agneta; Appelros, Peter; Forsberg, Anette

    2018-06-06

    After stroke, asymmetric weight distribution is common with decreased balance control in standing and walking. The six-spot step test (SSST) includes a 5-m walk during which one leg shoves wooden blocks out of circles marked on the floor, thus assessing the ability to take load on each leg. The aim of the present study was to investigate the convergent and discriminant validity and test-retest reliability of the SSST in persons with stroke. Eighty-one participants were included. A cross-sectional study was performed, in which the SSST was conducted twice, 3-7 days apart. Validity was investigated using measures of dynamic balance and walking. Reliability was assessed using intraclass correlation coefficient, standard error of the measurement (SEM), and smallest real difference (SRD). The convergent validity was strong to moderate, and the test-retest reliability was good. The SEM% was 14.7%, and the SRD% was 40.8% based on the mean of four walks shoving twice with the paretic and twice with the non-paretic leg. Values on random measurement error were high affecting the use of the SSST for follow-up evaluations but the SSST can be a complementary measure of gait and balance.

  7. Active solution of homography for pavement crack recovery with four laser lines.

    PubMed

    Xu, Guan; Chen, Fang; Wu, Guangwei; Li, Xiaotao

    2018-05-08

    An active solution method of the homography, which is derived from four laser lines, is proposed to recover the pavement cracks captured by the camera to the real-dimension cracks in the pavement plane. The measurement system, including a camera and four laser projectors, captures the projection laser points on the 2D reference in different positions. The projection laser points are reconstructed in the camera coordinate system. Then, the laser lines are initialized and optimized by the projection laser points. Moreover, the plane-indicated Plücker matrices of the optimized laser lines are employed to model the laser projection points of the laser lines on the pavement. The image-pavement homography is actively determined by the solutions of the perpendicular feet of the projection laser points. The pavement cracks are recovered by the active solution of homography in the experiments. The recovery accuracy of the active solution method is verified by the 2D dimension-known reference. The test case with the measurement distance of 700 mm and the relative angle of 8° achieves the smallest recovery error of 0.78 mm in the experimental investigations, which indicates the application potentials in the vision-based pavement inspection.

  8. Atomistic study of the solid state inside graphene nanobubbles.

    PubMed

    Iakovlev, Evgeny; Zhilyaev, Petr; Akhatov, Iskander

    2017-12-20

    A two-dimensional (2D) material placed on an atomically flat substrate can lead to the formation of surface nanobubbles trapping different types of substances. In this paper graphene nanobubbles of the radius of 7-34 nm with argon atoms inside are studied using molecular dynamics (MD). All modeled graphene nanobubbles except for the smallest ones exhibit an universal shape, i.e., a constant ratio of a bubble height to its footprint radius, which is in an agreement with experimental studies and their interpretation using the elastic theory of membranes. MD simulations reveal that argon does exist in a solid close-packed phase, although the internal pressure in the nanobubble is not sufficiently high for the ordinary crystallization that would occur in a bulk system. The smallest graphene bubbles with a radius of 7 nm exhibit an unusual "pancake" shape. Previously, nanobubbles with a similar pancake shape were experimentally observed in completely different systems at the interface between water and a hydrophobic surface.

  9. Third-order nonlinear optical properties of ADP crystal

    NASA Astrophysics Data System (ADS)

    Wang, Mengxia; Wang, Zhengping; Chai, Xiangxu; Sun, Yuxiang; Sui, Tingting; Sun, Xun; Xu, Xinguang

    2018-05-01

    By using the Z-scan method, we investigated the third-order nonlinear optical (NLO) properties of ADP crystal at different wavelengths (355, 532, and 1064 nm) and different orientations ([001], [100], [110], I and II). The experimental data were fitted by NLO theory, to give out the two photon absorption (TPA) coefficient β 2 and the nonlinear refractive index n 2. When the light source changed from a 40 ps, 1064 nm fundamental laser to a 30 ps, 355 nm third-harmonic-generation (THG) laser, the β 2 value increased about 5 times (0.2 × 10‑2 → 1 × 10‑2 cm GW‑1), and the n 2 value increased about 1.5 times (1.5 × 10‑16 → 2.2 × 10‑16 cm2 W‑1). Among all of the orientations, the [110] sample exhibits the smallest β 2, and the second smallest n 2. It indicates that this orientation and its surroundings will be the preferred directions for high-power laser applications of ADP crystal.

  10. Comparison of Video Head Impulse Test (vHIT) Gains Between Two Commercially Available Devices and by Different Gain Analytical Methods.

    PubMed

    Lee, Sang Hun; Yoo, Myung Hoon; Park, Jun Woo; Kang, Byung Chul; Yang, Chan Joo; Kang, Woo Suk; Ahn, Joong Ho; Chung, Jong Woo; Park, Hong Ju

    2018-06-01

    To evaluate whether video head impulse test (vHIT) gains are dependent on the measuring device and method of analysis. Prospective study. vHIT was performed in 25 healthy subjects using two devices simultaneously. vHIT gains were compared between these instruments and using five different methods of comparing position and velocity gains during head movement intervals. The two devices produced different vHIT gain results with the same method of analysis. There were also significant differences in the vHIT gains measured using different analytical methods. The gain analytic method that compares the areas under the velocity curve (AUC) of the head and eye movements during head movements showed lower vHIT gains than a method that compared the peak velocities of the head and eye movements. The former method produced the vHIT gain with the smallest standard deviation among the five procedures tested in this study. vHIT gains differ in normal subjects depending on the device and method of analysis used, suggesting that it is advisable for each device to have its own normal values. Gain calculations that compare the AUC of the head and eye movements during the head movements show the smallest variance.

  11. Which mode and potency of electrocoagulation yields the Smallest Unobstructed Area of the Fallopian Tubes?

    PubMed

    Campagnolo, Marcelo Ivo; Reis, Ricardo Dos; Santos, Marcele Oliveira Dos; Kliemann, Lúcia Maria; Savaris, Ricardo Francalacci

    2018-05-29

     To determine which mode and potency of electrocoagulation, using a modern electrosurgical generator, yields the smallest unobstructed area of the Fallopian tubes.  In an experimental study, tubes from 48 hysterectomies or tubal ligation were evaluated. Tubes were randomly allocated to one of the following groups: group A) 25 W x 5 seconds ( n  = 17); group B) 30 W x 5 seconds ( n  = 17); group C) 35 W x 5 seconds ( n  = 18), group D) 40 W x 5 seconds ( n  = 20); group E) 40 W x 5 seconds with visual inspection (blanch, swells, collapse) ( n  = 16); group F) 50 W x 5 seconds ( n  = 8). Bipolar electrocoagulation was performed in groups A to E, and monopolar electrocoagulation was performed in group F. Coagulation mode was used in all groups. Digital photomicrography of the transversal histological sections of the isthmic segment of the Fallopian tube were taken, and the median percentage of unobstructed luminal area (mm 2 ) was measured with ImageJ software (ImageJ, National Institutes of Health, Bethesda, MD, USA). The Kruskal-Wallis test or analysis of variance (ANOVA) was used for statistical analysis.  Ninety-six Fallopian tube sections were analyzed. The smallest median occluded area (%; range) of the Fallopian tube was obtained in the group with 40 W with visual inspection (8.3%; 0.9-40%), followed by the groups 25 W (9.1%; 0-35.9%), 40 W (14.2; 0.9-43.2%), 30 W (14.2; 0.9-49.7%), 35 W (15.1; 3-46.4%) and 50 W (38.2; 3.1-51%). No statistically significant difference was found among groups ( p  = 0.09, Kruskal-Wallis test).  The smallest unobstructed area was obtained with power setting at 40 W with visual inspection using a modern electrosurgical generator. However, no statistically significant difference in the unobstructed area was observed among the groups using these different modes and potencies. Thieme Revinter Publicações Ltda Rio de Janeiro, Brazil.

  12. Multi-time Scale Joint Scheduling Method Considering the Grid of Renewable Energy

    NASA Astrophysics Data System (ADS)

    Zhijun, E.; Wang, Weichen; Cao, Jin; Wang, Xin; Kong, Xiangyu; Quan, Shuping

    2018-01-01

    Renewable new energy power generation prediction error like wind and light, brings difficulties to dispatch the power system. In this paper, a multi-time scale robust scheduling method is set to solve this problem. It reduces the impact of clean energy prediction bias to the power grid by using multi-time scale (day-ahead, intraday, real time) and coordinating the dispatching power output of various power supplies such as hydropower, thermal power, wind power, gas power and. The method adopts the robust scheduling method to ensure the robustness of the scheduling scheme. By calculating the cost of the abandon wind and the load, it transforms the robustness into the risk cost and optimizes the optimal uncertainty set for the smallest integrative costs. The validity of the method is verified by simulation.

  13. Size of the Dynamic Bead in Polymers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agapov, Alexander L; Sokolov, Alexei P

    2010-01-01

    Presented analysis of neutron, mechanical, and MD simulation data available in the literature demonstrates that the dynamic bead size (the smallest subchain that still exhibits the Rouse-like dynamics) in most of the polymers is significantly larger than the traditionally defined Kuhn segment. Moreover, our analysis emphasizes that even the static bead size (e.g., chain statistics) disagrees with the Kuhn segment length. We demonstrate that the deficiency of the Kuhn segment definition is based on the assumption of a chain being completely extended inside a single bead. The analysis suggests that representation of a real polymer chain by the bead-and-spring modelmore » with a single parameter C cannot be correct. One needs more parameters to reflect correctly details of the chain structure in the bead-and-spring model.« less

  14. Superlattice optical device

    DOEpatents

    Biefeld, R.M.; Fritz, I.J.; Gourley, P.L.; Osbourn, G.C.

    A semiconductor optical device which includes a superlattice having direct transitions between conduction band and valence band states with the same wave vector, the superlattice being formed from a plurality of alternating layers of two or more different materials, at least the material with the smallest bandgap being an indirect bandgap material.

  15. 40 CFR 1037.104 - Exhaust emission standards for CO2, CH4, and N2O for heavy-duty vehicles at or below 14,000...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... additive deterioration factor of zero to measured CO2 emissions unless good engineering judgment indicates... eliminated from the pool. (v) Select the tested subconfiguration with the smallest absolute difference...

  16. Advances in the Surface Renewal Flux Measurement Method

    NASA Astrophysics Data System (ADS)

    Shapland, T. M.; McElrone, A.; Paw U, K. T.; Snyder, R. L.

    2011-12-01

    The measurement of ecosystem-scale energy and mass fluxes between the planetary surface and the atmosphere is crucial for understanding geophysical processes. Surface renewal is a flux measurement technique based on analyzing the turbulent coherent structures that interact with the surface. It is a less expensive technique because it does not require fast-response velocity measurements, but only a fast-response scalar measurement. It is therefore also a useful tool for the study of the global cycling of trace gases. Currently, surface renewal requires calibration against another flux measurement technique, such as eddy covariance, to account for the linear bias of its measurements. We present two advances in the surface renewal theory and methodology that bring the technique closer to becoming a fully independent flux measurement method. The first advance develops the theory of turbulent coherent structure transport associated with the different scales of coherent structures. A novel method was developed for identifying the scalar change rate within structures at different scales. Our results suggest that for canopies less than one meter in height, the second smallest coherent structure scale dominates the energy and mass flux process. Using the method for resolving the scalar exchange rate of the second smallest coherent structure scale, calibration is unnecessary for surface renewal measurements over short canopies. This study forms the foundation for analysis over more complex surfaces. The second advance is a sensor frequency response correction for measuring the sensible heat flux via surface renewal. Inexpensive fine-wire thermocouples are frequently used to record high frequency temperature data in the surface renewal technique. The sensible heat flux is used in conjunction with net radiation and ground heat flux measurements to determine the latent heat flux as the energy balance residual. The robust thermocouples commonly used in field experiments underestimate the sensible heat flux, yielding results that are less than 50% of the sensible heat flux measured with finer sensors. We present the methodology for correcting the thermocouple signal to avoid underestimating the heat flux at both the smallest and the second smallest coherent structure scale.

  17. The morphology of cometary dust: Subunit size distributions down to tens of nanometres

    NASA Astrophysics Data System (ADS)

    Mannel, Thurid; Bentley, Mark; Boakes, Peter; Jeszenszky, Harald; Levasseur-Regourd, Anny-Chantal; Schmied, Roland; Torkar, Klaus

    2017-04-01

    The Rosetta orbiter carried a dedicated analysis suite for cometary dust. One of the key instruments was MIDAS (Micro-Imaging Dust Analysis System), an atomic force microscope that scanned the surfaces of hundreds of (sub-)micrometre particles in 3D with resolutions down to nanometres. This provided the opportunity to study the morphology of the smallest cometary dust; initial investigation revealed that the particles are agglomerates of smaller subunits [1] with different structural properties [2]. To understand the (surface-) structure of the dust particles and the origin of their smallest building blocks, a number of particles were investigated in detail and the size distribution of their subunits determined [3]. Here we discuss the subunit size distributions ranging from tens of nanometres to a few micrometres. The differences between the subunit size distributions for particles collected pre-perihelion, close to perihelion, and during a huge outburst are examined, as well as the dependence of subunit size on particle size. A case where a particle was fragmented in consecutive scans allows a direct comparison of fragment and subunit size distributions. Finally, the small end of the subunit size distribution is investigated: the smallest determined sizes will be reviewed in the context of other cometary missions, interplanetary dust particles believed to originate from comets, and remote observations. It will be discussed if the smallest subunits can be interpreted as fundamental building blocks of our early Solar System and if their origin was in our protoplanetary disc or the interstellar material. References: [1] M.S. Bentley, R. Schmied, T. Mannel et al., Aggregate dust particles at comet 67P/Chruyumov-Gerasimenko, Nature, 537, 2016. doi:10.1038/nature19091 [2] T. Mannel, M.S. Bentley, R. Schmied et al., Fractal cometary dust - a window into the early Solar system, MNRAS, 462, 2016. doi:10.1093/mnras/stw2898 [3] R. Schmied, T. Mannel, H. Jeszenszky, M.S. Bentley, Properties of cometary dust down to the nanometre scale, poster at the conference 'Comets: A new vision after Rosetta/Philae' in Toulouse, 14-18 November 2016.

  18. Force decay of elastomeric chains - a mechanical design and product comparison study.

    PubMed

    Balhoff, David A; Shuldberg, Matthew; Hagan, Joseph L; Ballard, Richard W; Armbruster, Paul C

    2011-03-01

    To evaluate the percentage force decay of elastomeric chain products utilizing three different design mechanisms simulating canine retraction; and to evaluate the percentage force decay of elastomeric chain products from four different companies. In vitro, laboratory study. LSUHSC Dental School, New Orleans, LA, USA. Closed (non-spaced), grey elastomeric chains from four companies were selected for the study. Three acrylic resin jigs were constructed to provide a framework for three simulated space closure mechanisms. The 6-5-3, the chain loop, and the 6-3 were the configuration mechanisms used in the study. An electronic force gauge was used to measure the percentage force decay associated with each elastomeric chain over 28 days at preselected times. There was a significant difference in the mean percentage force decay for the three different mechanisms (P < 0·001). For all four companies, the 6-3 mechanical design had the smallest mean percentage force decay. There was a significant difference in the mean percentage force decay for the different companies (P < 0·001). For all three mechanisms, Ormco had the smallest percentage force decay while Unitek had the highest percentage force decay. The significant difference in the mean percentage force decay for the different mechanisms suggests that the 6-3 design is a more efficient means of closing extraction spaces utilizing elastomeric chains.

  19. Lift vs. drag based mechanisms for vertical force production in the smallest flying insects.

    PubMed

    Jones, S K; Laurenza, R; Hedrick, T L; Griffith, B E; Miller, L A

    2015-11-07

    We used computational fluid dynamics to determine whether lift- or drag-based mechanisms generate the most vertical force in the flight of the smallest insects. These insects fly at Re on the order of 4-60 where viscous effects are significant. Detailed quantitative data on the wing kinematics of the smallest insects is not available, and as a result both drag- and lift-based strategies have been suggested as the mechanisms by which these insects stay aloft. We used the immersed boundary method to solve the fully-coupled fluid-structure interaction problem of a flexible wing immersed in a two-dimensional viscous fluid to compare three idealized hovering kinematics: a drag-based stroke in the vertical plane, a lift-based stroke in the horizontal plane, and a hybrid stroke on a tilted plane. Our results suggest that at higher Re, a lift-based strategy produces more vertical force than a drag-based strategy. At the Re pertinent to small insect hovering, however, there is little difference in performance between the two strategies. A drag-based mechanism of flight could produce more vertical force than a lift-based mechanism for insects at Re<5; however, we are unaware of active fliers at this scale. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Relative and Absolute Interrater Reliabilities of a Hand-Held Myotonometer to Quantify Mechanical Muscle Properties in Patients with Acute Stroke in an Inpatient Ward

    PubMed Central

    2017-01-01

    Introduction The reliability of using MyotonPRO to quantify muscles mechanical properties in a ward setting for the acute stroke population remains unknown. Aims To investigate the within-session relative and absolute interrater reliability of MyotonPRO. Methods Mechanical properties of biceps brachii, brachioradialis, rectus femoris, and tibialis anterior were recorded at bedside. Participants were within 1 month of the first occurrence of stroke. Relative reliability was assessed by intraclass correlation coefficient (ICC). Absolute reliability was assessed by standard error of measurement (SEM), SEM%, smallest real difference (SRD), SRD%, and the Bland-Altman 95% limits of agreement. Results ICCs of all studied muscles ranged between 0.63 and 0.97. The SEM of all muscles ranged within 0.30–0.88 Hz for tone, 0.07–0.19 for decrement, 6.42–20.20 N/m for stiffness, and 0.04–0.07 for creep. The SRD of all muscles ranged within 0.70–2.05 Hz for tone, 0.16–0.45 for decrement, 14.98–47.15 N/m for stiffness, and 0.09–0.17 for creep. Conclusions MyotonPRO demonstrated acceptable relative and absolute reliability in a ward setting for patients with acute stroke. However, results must be interpreted with caution, due to the varying level of consistency between different muscles, as well as between different parameters within a muscle. PMID:29164148

  1. Reliability and Usefulness of Linear Sprint Testing in Adolescent Rugby Union and League Players.

    PubMed

    Darrall-Jones, Joshua D; Jones, Ben; Roe, Gregory; Till, Kevin

    2016-05-01

    The purpose of this study was to evaluate (a) whether there were differences in sprint times at 5, 10, 20, 30, and 40 m between rugby union and rugby league players, (b) determine the reliability and usefulness of linear sprint testing in adolescent rugby players. Data were collected on 28 rugby union and league academy players over 2 testing sessions, with 3-day rest between sessions. Rugby league players were faster at 5 m than rugby union players, with further difference unclear. Sprint time at 10, 20, 30, and 40 m was all reliable (coefficient of variation [CV] = 3.1, 1.8, 2.0, and 1.3%) but greater than the smallest worthwhile change (SWC [0.2 × between-subject SD]), rating the test as marginal for usefulness. Although the test was incapable of detecting the SWC, we recommend that practitioners and researchers use Hopkins' proposed method; whereby plotting the change score of the individual at each split (±typical error [TE] expressed as a CV) against the SWC and visually inspecting whether the TE crosses into the SWC are capable of identifying whether a change is both real (greater than the noise of the test, i.e., >TE) and of practical significance (>SWC). Researchers and practitioners can use the TE and SWC from this study to assess changes in performance of adolescent rugby players when using single beam timing gates.

  2. Brood division in birds in relation to offspring size: sibling rivalry and parental control

    PubMed

    Slagsvold

    1997-12-01

    In some altricial birds with biparental care, it is the female, and in others the male, that provides more food to the smallest offspring within the brood. Many hypotheses have been proposed to account for such puzzling patterns of parental care. A parsimonious explanation is that no difference exists between the parents in priority of care but that differences arise simply from sibling rivalry, with dominant chicks trying to position themselves closest to the parent that provides most care (the sibling rivalry hypothesis). A refinement of the idea is that parents use the way they approach the chicks to counter selfish offspring and in this way control allocation of care (the parental approaching hypothesis). A comparison across species suggested that female care of the smallest chick within a brood is the ancestral and most common pattern. However, strong variation exists within single populations. In one species, the American robin, Turdus migratorius the sibling rivalry hypothesis and the parental approaching hypothesis were both supported because in broods where males provided more care than females, the largest chick was predominantly fed by the male whereas the smallest chick was predominantly fed by the female. When the male provided less care than the female, an opposite result was found. The same patterns of allocation of care also seemed to exist when chicks were quite immobile just after having left the nest and when their positions were experimentally controlled, suggesting parental control.Copyright 1997 The Association for the Study of Animal BehaviourCopyright 1997The Association for the Study of Animal Behaviour.

  3. Smaller external notebook mice have different effects on posture and muscle activity.

    PubMed

    Oude Hengel, Karen M; Houwink, Annemieke; Odell, Dan; van Dieën, Jaap H; Dennerlein, Jack T

    2008-07-01

    Extensive computer mouse use is an identified risk factor for computer work-related musculoskeletal disorders; however, notebook computer mouse designs of varying sizes have not been formally evaluated but may affect biomechanical risk factors. Thirty adults performed a set of mouse tasks with five notebook mice, ranging in length from 75 to 105 mm and in width from 35 to 65 mm, and a reference desktop mouse. An electro-magnetic motion analysis system measured index finger (metacarpophalangeal joint), wrist and forearm postures, and surface electromyography measured muscle activity of three extensor muscles in the forearm and the first dorsal interosseus. The smallest notebook mice were found to promote less neutral postures (up to 3.2 degrees higher metacarpophalangeal joint adduction; 6.5 degrees higher metacarpophalangeal joint flexion, 2.3 degrees higher wrist extension) and higher muscle activity (up to 4.1% of maximum voluntary contraction higher wrist extensor muscle activity). Participants with smaller hands had overall more non-neutral postures than participants with larger hands (up to 5.6 degrees higher wrist extension and 5.9 degrees higher pronation); while participants with larger hands were more influenced by the smallest notebook mice (up to 3.6 degrees higher wrist extension and 5.5% of maximum voluntary contraction higher wrist extensor values). Self-reported ratings showed that while participants preferred smaller mice for portability; larger mice scored higher on comfort and usability. The smallest notebook mice increased the intensity of biomechanical exposures. Longer term mouse use could enhance these differences, having a potential impact on the prevention of work-related musculoskeletal disorders.

  4. Turn off the Television and Read

    ERIC Educational Resources Information Center

    Hodapp, Albert Fed

    2016-01-01

    Aaron (2005) described the "family as the nation's smallest school" and "the home as the first school." Furthermore, studies document that 90% of the differences in academic achievement can be explained by five factors: (a) two-parent households; (b) school absenteeism; (c) amount read for homework; (d) quality and quantity of…

  5. Scientific and Engineering Studies: Spectral Estimation

    DTIC Science & Technology

    1989-08-11

    PROBLEM SOLUTION Four different constrained problems will be addressed in this section: con- strained window duration L ; constrained equivalent...sm(frtp + C, ^ smk ) » 0. (B_18) (B-19) The simultaneous solution of (B-ll) and (B-18), with smallest *< , is then given by q =.?0n l^fi

  6. Min and Max Exponential Extreme Interval Values and Statistics

    ERIC Educational Resources Information Center

    Jance, Marsha; Thomopoulos, Nick

    2009-01-01

    The extreme interval values and statistics (expected value, median, mode, standard deviation, and coefficient of variation) for the smallest (min) and largest (max) values of exponentially distributed variables with parameter ? = 1 are examined for different observation (sample) sizes. An extreme interval value g[subscript a] is defined as a…

  7. Laplace-Fourier-domain dispersion analysis of an average derivative optimal scheme for scalar-wave equation

    NASA Astrophysics Data System (ADS)

    Chen, Jing-Bo

    2014-06-01

    By using low-frequency components of the damped wavefield, Laplace-Fourier-domain full waveform inversion (FWI) can recover a long-wavelength velocity model from the original undamped seismic data lacking low-frequency information. Laplace-Fourier-domain modelling is an important foundation of Laplace-Fourier-domain FWI. Based on the numerical phase velocity and the numerical attenuation propagation velocity, a method for performing Laplace-Fourier-domain numerical dispersion analysis is developed in this paper. This method is applied to an average-derivative optimal scheme. The results show that within the relative error of 1 per cent, the Laplace-Fourier-domain average-derivative optimal scheme requires seven gridpoints per smallest wavelength and smallest pseudo-wavelength for both equal and unequal directional sampling intervals. In contrast, the classical five-point scheme requires 23 gridpoints per smallest wavelength and smallest pseudo-wavelength to achieve the same accuracy. Numerical experiments demonstrate the theoretical analysis.

  8. Effect of geometric configuration on the electrocaloric properties of nanoscale ferroelectric materials

    NASA Astrophysics Data System (ADS)

    Hou, Xu; Li, Huiyu; Shimada, Takahiro; Kitamura, Takayuki; Wang, Jie

    2018-03-01

    The electrocaloric properties of ferroelectrics are highly dependent on the domain structure in the materials. For nanoscale ferroelectric materials, the domain structure is greatly influenced by the geometric configuration of the system. Using a real-space phase field model based on the Ginzburg-Landau theory, we investigate the effect of geometric configurations on the electrocaloric properties of nanoscale ferroelectric materials. The ferroelectric hysteresis loops under different temperatures are simulated for the ferroelectric nano-metamaterials with square, honeycomb, and triangular Archimedean geometric configurations. The adiabatic temperature changes (ATCs) for three ferroelectric nano-metamaterials under different electric fields are calculated from the Maxwell relationship based on the hysteresis loops. It is found that the honeycomb specimen exhibits the largest ATC of Δ T = 4.3 °C under a field of 391.8 kV/cm among three geometric configurations, whereas the square specimen has the smallest ATC of Δ T = 2.7 °C under the same electric field. The different electrocaloric properties for three geometric configurations stem from the different domain structures. There are more free surfaces perpendicular to the electric field in the square specimen than the other two specimens, which restrict more polarizations perpendicular to the electric field, resulting in a small ATC. Due to the absence of free surfaces perpendicular to the electric field in the honeycomb specimen, the change of polarization with temperature in the direction of the electric field is more easy and thus leads to a large ATC. The present work suggests a novel approach to obtain the tunable electrocaloric properties in nanoscale ferroelectric materials by designing their geometric configurations.

  9. Evaluation of correlation between dissolution rates of loxoprofen tablets and their surface morphology observed by scanning electron microscope and atomic force microscope.

    PubMed

    Yoshikawa, Shinichi; Murata, Ryo; Shida, Shigenari; Uwai, Koji; Suzuki, Tsuneyoshi; Katsumata, Shunji; Takeshita, Mitsuhiro

    2010-01-01

    We observed the surface morphological structures of 60 mg tablets of Loxonin, Loxot, and Lobu using scanning electron microscope (SEM) and atomic force microscope (AFM) to evaluate the dissolution rates. We found a significant difference among the initial dissolution rates of the three kinds of loxoprofen sodium tablets. Petal forms of different sizes were commonly observed on the surface of the Loxonin and Loxot tablets in which loxoprofen sodium was confirmed by measuring the energy-dispersible X-ray (EDX) spectrum of NaKalpha using SEM. However, a petal form was not observed on the surface of the Lobu tablet, indicating differences among the drug production processes. Surface area and particle size of the principal ingredient in tablets are important factors for dissolution rate. The mean size of the smallest fine particles constituting each tablet was also determined with AFM. There was a correlation between the initial dissolution rate and the mean size of the smallest particles in each tablet. Visualizing tablet surface morphology using SEM and AFM provides information on the drug production processes and initial dissolution rate, and is associated with the time course of pharmacological activities after tablet administration.

  10. Soil carbon inventories under a bioenergy crop (switchgrass): Measurement limitations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garten, C.T. Jr.; Wullschleger, S.D.

    Approximately 5 yr after planting, coarse root carbon (C) and soil organic C (SOC) inventories were compared under different types of plant cover at four switchgrass (Panicum virgatum L.) production field trials in the southeastern USA. There was significantly more coarse root C under switchgrass (Alamo variety) and forest cover than tall fescue (Festuca arundinacea Schreb.), corn (Zea mays L.), or native pastures of mixed grasses. Inventories of SOC under switchgrass were not significantly greater than SOC inventories under other plant covers. At some locations the statistical power associated with ANOVA of SOC inventories was low, which raised questions aboutmore » whether differences in SOC could be detected statistically. A minimum detectable difference (MDD) for SOC inventories was calculated. The MDD is the smallest detectable difference between treatment means once the variation, significance level, statistical power, and sample size are specified. The analysis indicated that a difference of {approx}50 mg SOC/cm{sup 2} or 5 Mg SOC/ha, which is {approx}10 to 15% of existing SOC, could be detected with reasonable sample sizes and good statistical power. The smallest difference in SOC inventories that can be detected, and only with exceedingly large sample sizes, is {approx}2 to 3%. These measurement limitations have implications for monitoring and verification of proposals to ameliorate increasing global atmospheric CO{sub 2} concentrations by sequestering C in soils.« less

  11. THE SMALLEST FIELD OF DEFINITION OF A SUBGROUP OF THE GROUP \\mathrm{PSL}_2

    NASA Astrophysics Data System (ADS)

    Vinberg, È. B.

    1995-02-01

    As previously proved by the author, for each semisimple algebraic group of adjoint type that is dense in the Zariski topology there exists a smallest field of definition which is an invariant of the class of commensurable subgroups. In the present paper an algorithm is given for finding the smallest field of definition of a dense finitely generated subgroup of the group \\mathrm{PSL}_2(\\mathbb{C}). A criterion for arithmeticity of a lattice in \\mathrm{PSL}_2(\\mathbb{R}) or \\mathrm{PSL}_2(\\mathbb{C}) in terms of this field is presented.Bibliography: 7 titles.

  12. Explaining the Railsback stretch in terms of the inharmonicity of piano tones and sensory dissonance.

    PubMed

    Giordano, N

    2015-10-01

    The perceptual results of Plomp and Levelt [J. Acoust. Soc. Am. 38, 548-560 (1965)] for the sensory dissonance of a pair of pure tones are used to estimate the dissonance of pairs of piano tones. By using the spectra of tones measured for a real piano, the effect of the inharmonicity of the tones is included. This leads to a prediction for how the tuning of this piano should deviate from an ideal equal tempered scale so as to give the smallest sensory dissonance and hence give the most pleasing tuning. The results agree with the well known "Railsback stretch," the average tuning curve produced by skilled piano technicians. The authors' analysis thus gives a quantitative explanation of the magnitude of the Railsback stretch in terms of the human perception of dissonance.

  13. Micro-battery Development for Juvenile Salmon Acoustic Telemetry System Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Honghao; Cartmell, Samuel S.; Wang, Qiang

    2014-01-21

    The Juvenile Salmon Acoustic Telemetry System (JSATS) project supported by the U.S. Army Corps of Engineers, Portland District, has yielded the smallest acoustic fish tag transmitter commercially available to date. In order to study even smaller fish populations and make the transmitter injectable by needles, the JSATS acoustic micro transmitter needs to be further downsized. This study focuses on the optimization of microbattery design based on Li/CFx chemistry. Through appropriate modifications, a steady high-rate pulse current with desirable life time has been achieved while the weight and volume of the battery is largely reduced. The impedance variation in as-designed microbatteriesmore » is systematically compared with that of currently used watch batteries in JSATS with an attempt to understand the intrinsic factors that control the performances of microbatteries under the real testing environments.« less

  14. California spotted owl habitat characteristics and use

    Treesearch

    Susan L. Roberts

    2017-01-01

    California spotted owls (Strix occidentalis occidentalis) establish large home ranges averaging about 1279 ha (3,160 ac) (table 3-1), and within these home ranges individual owls select habitat at different scales, depending on their activity. At the smallest spatial scale, the nest tree, it appears there is very limited flexibility in the...

  15. Efficient Remainder Rule

    ERIC Educational Resources Information Center

    Firozzaman, Firoz; Firoz, Fahim

    2017-01-01

    Understanding the solution of a problem may require the reader to have background knowledge on the subject. For instance, finding an integer which, when divided by a nonzero integer leaves a remainder; but when divided by another nonzero integer may leave a different remainder. To find a smallest positive integer or a set of integers following the…

  16. The Academic Preparation of Idaho Science Teachers Based on School District Size.

    ERIC Educational Resources Information Center

    Heikkinen, Michael W.

    1987-01-01

    Certification records of 435 Idaho science teachers analyzed by school district size revealed significant differences: more physiology, earth science, and chemistry I teachers in largest districts had endorsements to teach assigned subjects; more earth science and chemistry I teachers in smallest districts had neither major nor minor in subjects…

  17. Effects of injection nozzle exit width on rotating detonation engine

    NASA Astrophysics Data System (ADS)

    Sun, Jian; Zhou, Jin; Liu, Shijie; Lin, Zhiyong; Cai, Jianhua

    2017-11-01

    A series of numerical simulations of RDE modeling real injection nozzles with different exit widths are performed in this paper. The effects of nozzle exit width on chamber inlet state, plenum flowfield and detonation propagation are analyzed. The results are compared with that using an ideal injection model. Although the ideal injection model is a good approximation method to model RDE inlet, the two-dimensional effects of real nozzles are ignored in the ideal injection model so that some complicated phenomena such as the reflected waves caused by the nozzle walls and the reversed flow into the nozzles can not be modeled accurately. Additionally, the ideal injection model overpredicts the block ratio. In all the cases that stabilize at one-wave mode, the block ratio increases as the nozzle exit width gets smaller. The dual-wave mode case also has a relatively high block ratio. A pressure oscillation in the plenum with the same main frequency with the rotating detonation wave is observed. A parameter σ is applied to describe the non-uniformity in the plenum. σ increases as the nozzle exit width gets larger. Under some condition, the heat release on the interface of fresh premixed gas layer and detonation products can be strong enough to induce a new detonation wave. A spontaneous mode-transition process is observed for the smallest exit width case. Due to the detonation products existing in the premixed gas layer before the detonation wave, the detonation wave will propagate through reactants and products alternately, and therefore its strength will vary with time, especially near the chamber inlet. This tendency gets weaker as the injection nozzle exit width increases.

  18. In vitro large-scale experimental and theoretical studies for the realization of bi-directional brain-prostheses.

    PubMed

    Bonifazi, Paolo; Difato, Francesco; Massobrio, Paolo; Breschi, Gian L; Pasquale, Valentina; Levi, Timothée; Goldin, Miri; Bornat, Yannick; Tedesco, Mariateresa; Bisio, Marta; Kanner, Sivan; Galron, Ronit; Tessadori, Jacopo; Taverna, Stefano; Chiappalone, Michela

    2013-01-01

    Brain-machine interfaces (BMI) were born to control "actions from thoughts" in order to recover motor capability of patients with impaired functional connectivity between the central and peripheral nervous system. The final goal of our studies is the development of a new proof-of-concept BMI-a neuromorphic chip for brain repair-to reproduce the functional organization of a damaged part of the central nervous system. To reach this ambitious goal, we implemented a multidisciplinary "bottom-up" approach in which in vitro networks are the paradigm for the development of an in silico model to be incorporated into a neuromorphic device. In this paper we present the overall strategy and focus on the different building blocks of our studies: (i) the experimental characterization and modeling of "finite size networks" which represent the smallest and most general self-organized circuits capable of generating spontaneous collective dynamics; (ii) the induction of lesions in neuronal networks and the whole brain preparation with special attention on the impact on the functional organization of the circuits; (iii) the first production of a neuromorphic chip able to implement a real-time model of neuronal networks. A dynamical characterization of the finite size circuits with single cell resolution is provided. A neural network model based on Izhikevich neurons was able to replicate the experimental observations. Changes in the dynamics of the neuronal circuits induced by optical and ischemic lesions are presented respectively for in vitro neuronal networks and for a whole brain preparation. Finally the implementation of a neuromorphic chip reproducing the network dynamics in quasi-real time (10 ns precision) is presented.

  19. Evaluation of four commercial quantitative real-time PCR kits with inhibited and degraded samples.

    PubMed

    Holmes, Amy S; Houston, Rachel; Elwick, Kyleen; Gangitano, David; Hughes-Stamm, Sheree

    2018-05-01

    DNA quantification is a vital step in forensic DNA analysis to determine the optimal input amount for DNA typing. A quantitative real-time polymerase chain reaction (qPCR) assay that can predict DNA degradation or inhibitors present in the sample prior to DNA amplification could aid forensic laboratories in creating a more streamlined and efficient workflow. This study compares the results from four commercial qPCR kits: (1) Investigator® Quantiplex® Pro Kit, (2) Quantifiler® Trio DNA Quantification Kit, (3) PowerQuant® System, and (4) InnoQuant® HY with high molecular weight DNA, low template samples, degraded samples, and DNA spiked with various inhibitors.The results of this study indicate that all kits were comparable in accurately predicting quantities of high quality DNA down to the sub-picogram level. However, the InnoQuant(R) HY kit showed the highest precision across the DNA concentration range tested in this study. In addition, all kits performed similarly with low concentrations of forensically relevant PCR inhibitors. However, in general, the Investigator® Quantiplex® Pro Kit was the most tolerant kit to inhibitors and provided the most accurate quantification results with higher concentrations of inhibitors (except with salt). PowerQuant® and InnoQuant® HY were the most sensitive to inhibitors, but they did indicate significant levels of PCR inhibition. When quantifying degraded samples, each kit provided different degradation indices (DI), with Investigator® Quantiplex® Pro indicating the largest DI and Quantifiler® Trio indicating the smallest DI. When the qPCR kits were paired with their respective STR kit to genotype highly degraded samples, the Investigator® 24plex QS and GlobalFiler® kits generated more complete profiles when the small target concentrations were used for calculating input amount.

  20. CompCytogen of two of the smallest Amazonian fishes: Fluviphylax simplex Costa, 1996 and Fluviphylax zonatus Costa, 1996 (Cyprinodontiformes, Poeciliidae).

    PubMed

    Souza, E R; Ribeiro, L B; Feldberg, E; Hrbek, I P Farias T; Gross, M C

    2011-01-01

    The genus Fluviphylax Whitley, 1965is comprized of five valid species (Fluviphylax pygmaeus Myers et Carvalho, 1955, Fluviphylax zonatus, Fluviphylax simplex, Fluviphylax obscurus Costa, 1996,and Fluviphylax palikur Costa et Le Bail, 1999), which are endemic to the Amazon region. These fishes are the smallest known South American vertebrates and among the smallest know vertebrates on Earth. All species but the type Fluviphylax pygmaeus have been described in late 1990's, and much remains unknown about the biology, taxonomy and systematics of this group of fishes. The aims of the present study were to establish the diploid and haploid number of Fluviphylax zonatus and Fluviphylax simplex, and to find species-specific markers for the discrimination of taxa. The diploid number for both species was 48 chromosomes, with no sex chromosome heteromorphism. Fluviphylax zonatus exhibited the karyotypic formula 4m+8sm+22st+14a and FN=82, and Fluviphylax simplex exhibited 4m+16sm+18st+10a and FN=86. The determination of the total mean length of the chromosomes and their grouping into five size classes demonstrated different chromosome composition of the two species. This difference was further supported by the distribution of constitutive heterochromatin. The meiotic analysis revealed 24 bivalents in both species, but Fluviphylax zonatus exhibited chromosomes with late pairing of the telomeric portions in the pachytene. These data reveal that cytogenetic characterization is useful and important for the discrimination of these species. Our study further indicates that this method could be employed in the analysis of other species of small fishes that are difficult to distinguish using traditional morphological traits or are morphologically cryptic.

  1. Efficacy of ozone and other treatment modalities for retained placenta in dairy cows.

    PubMed

    Zobel, R; Tkalčić, S

    2013-02-01

    Retained placenta is a worldwide recognized clinical condition in puerperal cows, which can significantly affect their health and fertility. Available treatment modalities are often of questionable efficacy or associated with time constraints, practicality or monetary considerations for their wide application in a routine dairy practice. The objective of this study was to compare and assess the efficacy of different treatment options, including a novel ozone treatment, for the retained placenta. Two hundred cows diagnosed with retained placenta were divided into five treatment groups, each receiving a different treatment option. Group A (n = 40) was given a combination treatment of intrauterine ozone and parenteral cephalexin; group B (n = 40) was given intrauterine ozone; group C (n = 40) was given a combination of parenteral cephalexin and intrauterine antibiotic tablets; group D (n = 40) was given only parenteral cephalexin and group E (n = 40) was given parenteral prostaglandins in 11-day intervals. The control group (group Z, n = 200) included cows that gave birth without assistance and were not diagnosed with a retained placenta. The ozone treatment (groups A and B) was found to be the most effective modality resulting in the shortest period of days open, the smallest number of artificial inseminations until pregnancy, the smallest number of animals diagnosed with fever within 10 days post-calving, the highest percentage of animals pregnant within 200 days after calving and the smallest number of animals culled because of infertility, when compared to the other treatment groups. The intrauterine ozone flush therefore has a potential as an efficacious and cost-effective treatment option for retained placenta, with an overall positive effect on puerperal health and fertility in cows. © 2012 Blackwell Verlag GmbH.

  2. Diagnostic Capability of Peripapillary Three-dimensional Retinal Nerve Fiber Layer Volume for Glaucoma Using Optical Coherence Tomography Volume Scans.

    PubMed

    Khoueir, Ziad; Jassim, Firas; Poon, Linda Yi-Chieh; Tsikata, Edem; Ben-David, Geulah S; Liu, Yingna; Shieh, Eric; Lee, Ramon; Guo, Rong; Papadogeorgou, Georgia; Braaf, Boy; Simavli, Huseyin; Que, Christian; Vakoc, Benjamin J; Bouma, Brett E; de Boer, Johannes F; Chen, Teresa C

    2017-10-01

    To determine the diagnostic capability of peripapillary 3-dimensional (3D) retinal nerve fiber layer (RNFL) volume measurements from spectral-domain optical coherence tomography (OCT) volume scans for open-angle glaucoma (OAG). Assessment of diagnostic accuracy. Setting: Academic clinical setting. Total of 180 patients (113 OAG and 67 normal subjects). One eye per subject was included. Peripapillary 3D RNFL volumes were calculated for global, quadrant, and sector regions, using 4 different-size annuli. Peripapillary 2D RNFL thickness circle scans were also obtained. Area under the receiver operating characteristic curve (AUROC) values, sensitivity, specificity, positive and negative predictive values, positive and negative likelihood ratios. Among all 2D and 3D RNFL parameters, best diagnostic capability was associated with inferior quadrant 3D RNFL volume of the smallest annulus (AUROC value 0.977). Otherwise, global 3D RNFL volume AUROC values were comparable to global 2D RNFL thickness AUROC values for all 4 annulus sizes (P values: .0593 to .6866). When comparing the 4 annulus sizes for global RNFL volume, the smallest annulus had the best AUROC values (P values: .0317 to .0380). The smallest-size annulus may have the best diagnostic potential, partly owing to having no areas excluded for being larger than the 6 × 6 mm 2 scanned region. Peripapillary 3D RNFL volume showed excellent diagnostic performance for detecting glaucoma. Peripapillary 3D RNFL volume parameters have the same or better diagnostic capability compared to peripapillary 2D RNFL thickness measurements, although differences were not statistically significant. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Survival differences and the effect of environmental instability on breeding dispersal in an Adélie penguin meta-population

    PubMed Central

    Dugger, Katie M.; Ainley, David G.; Lyver, Phil O'B.; Barton, Kerry; Ballard, Grant

    2010-01-01

    High survival and breeding philopatry was previously confirmed for the Adélie penguin (Pygoscelis adeliae) during a period of stable environmental conditions. However, movements of breeding adults as a result of an unplanned natural experiment within a four-colony meta-population provided interesting insights into this species’ population dynamics. We used multistate mark-recapture models to investigate apparent survival and dispersal of breeding birds in the southwestern Ross Sea during 12 breeding seasons (1996–2007). The natural experiment was facilitated by the temporary grounding of two immense icebergs that (i) erected a veritable fence separating colonies and altering migration routes and (ii) added additional stress by trapping extensive sea ice in the region during 5 of 12 y. Colony size varied by orders of magnitude, allowing investigation of apparent survival and dispersal rates in relation to both environmental conditions and colony size within this meta-population. Apparent survival was lowest for the smallest colony (4,000 pairs) and similar for the medium (45,000 pairs) and large colonies (155,000 pairs), despite increased foraging effort expended by breeders at the largest colony. Dispersal of breeding birds was low (<1%), except during years of difficult environmental conditions when movements increased, especially away from the smallest colony (3.5%). Decreased apparent survival at the smallest colony could reflect differences in migration chronology and winter habitat use compared with the other colonies, or it may reflect increased permanent emigration to colonies outside this meta-population. Contrary to current thought, breeding penguins are not always philopatric. Rather, stressful conditions can significantly increase dispersal rates. PMID:20566874

  4. Project environmental microbiology as related to planetary quarantine

    NASA Technical Reports Server (NTRS)

    Pflug, I. J.

    1974-01-01

    Microbiological analyses of soil particles allow for the following conclusions: (1) there is a considerable range in the values of aerobic, mesophilic microbial counts associated with different size soil fractions; (2) as soil particle size increases, there is an increase in the mean microbial concentration per particle; (3) plate counts of aerobic, mesophilic organisms in unheated soils yielded a mean concentration of about six organisms per particle for the smallest soil fraction; (4) aerobic, mesophilic counts for sonicated particles heated at 80 C for 20 minutes yielded mean values of about two organisms per particle for the smallest particles; (5) some actinomycetes associated with the soil fractions could survive dry heat treatment at 110 C for one hour; and (6) soil particles stored under ambient laboratory conditions for 2.5 years aerobic, mesophilic plate counts which were comparable or slightly greater than the counts for more recently collected soil.

  5. The effect of displacement on sensitivity to first- and second-order global motion in 5-year-olds and adults.

    PubMed

    Ellemberg, D; Lewis, T L; Maurer, D; Lee, B; Ledgeway, T; Guilemot, J P; Lepore, F

    2010-01-01

    We compared the development of sensitivity to first- versus second-order global motion in 5-year-olds (n=24) and adults (n=24) tested at three displacements (0.1, 0.5 and 1.0 degrees). Sensitivity was measured with Random-Gabor Kinematograms (RGKs) formed with luminance-modulated (first-order) or contrast-modulated (second-order) concentric Gabor patterns. Five-year-olds were less sensitive than adults to the direction of both first- and second-order global motion at every displacement tested. In addition, the immaturity was smallest at the smallest displacement, which required the least spatial integration, and smaller for first-order than for second-order global motion at the middle displacement. The findings suggest that the development of sensitivity to global motion is limited by the development of spatial integration and by different rates of development of sensitivity to first- versus second-order signals.

  6. Determination of the optimal level for combining area and yield estimates

    NASA Technical Reports Server (NTRS)

    Bauer, M. E. (Principal Investigator); Hixson, M. M.; Jobusch, C. D.

    1981-01-01

    Several levels of obtaining both area and yield estimates of corn and soybeans in Iowa were considered: county, refined strata, refined/split strata, crop reporting district, and state. Using the CCEA model form and smoothed weather data, regression coefficients at each level were derived to compute yield and its variance. Variances were also computed with stratum level. The variance of the yield estimates was largest at the state and smallest at the county level for both crops. The refined strata had somewhat larger variances than those associated with the refined/split strata and CRD. For production estimates, the difference in standard deviations among levels was not large for corn, but for soybeans the standard deviation at the state level was more than 50% greater than for the other levels. The refined strata had the smallest standard deviations. The county level was not considered in evaluation of production estimates due to lack of county area variances.

  7. Evaluation of different approaches for identifying optimal sites to predict mean hillslope soil moisture content

    NASA Astrophysics Data System (ADS)

    Liao, Kaihua; Zhou, Zhiwen; Lai, Xiaoming; Zhu, Qing; Feng, Huihui

    2017-04-01

    The identification of representative soil moisture sampling sites is important for the validation of remotely sensed mean soil moisture in a certain area and ground-based soil moisture measurements in catchment or hillslope hydrological studies. Numerous approaches have been developed to identify optimal sites for predicting mean soil moisture. Each method has certain advantages and disadvantages, but they have rarely been evaluated and compared. In our study, surface (0-20 cm) soil moisture data from January 2013 to March 2016 (a total of 43 sampling days) were collected at 77 sampling sites on a mixed land-use (tea and bamboo) hillslope in the hilly area of Taihu Lake Basin, China. A total of 10 methods (temporal stability (TS) analyses based on 2 indices, K-means clustering based on 6 kinds of inputs and 2 random sampling strategies) were evaluated for determining optimal sampling sites for mean soil moisture estimation. They were TS analyses based on the smallest index of temporal stability (ITS, a combination of the mean relative difference and standard deviation of relative difference (SDRD)) and based on the smallest SDRD, K-means clustering based on soil properties and terrain indices (EFs), repeated soil moisture measurements (Theta), EFs plus one-time soil moisture data (EFsTheta), and the principal components derived from EFs (EFs-PCA), Theta (Theta-PCA), and EFsTheta (EFsTheta-PCA), and global and stratified random sampling strategies. Results showed that the TS based on the smallest ITS was better (RMSE = 0.023 m3 m-3) than that based on the smallest SDRD (RMSE = 0.034 m3 m-3). The K-means clustering based on EFsTheta (-PCA) was better (RMSE <0.020 m3 m-3) than these based on EFs (-PCA) and Theta (-PCA). The sampling design stratified by the land use was more efficient than the global random method. Forty and 60 sampling sites are needed for stratified sampling and global sampling respectively to make their performances comparable to the best K-means method (EFsTheta-PCA). Overall, TS required only one site, but its accuracy was limited. The best K-means method required <8 sites and yielded high accuracy, but extra soil and terrain information is necessary when using this method. The stratified sampling strategy can only be used if no pre-knowledge about soil moisture variation is available. This information will help in selecting the optimal methods for estimation the area mean soil moisture.

  8. Enumeration of Smallest Intervention Strategies in Genome-Scale Metabolic Networks

    PubMed Central

    von Kamp, Axel; Klamt, Steffen

    2014-01-01

    One ultimate goal of metabolic network modeling is the rational redesign of biochemical networks to optimize the production of certain compounds by cellular systems. Although several constraint-based optimization techniques have been developed for this purpose, methods for systematic enumeration of intervention strategies in genome-scale metabolic networks are still lacking. In principle, Minimal Cut Sets (MCSs; inclusion-minimal combinations of reaction or gene deletions that lead to the fulfilment of a given intervention goal) provide an exhaustive enumeration approach. However, their disadvantage is the combinatorial explosion in larger networks and the requirement to compute first the elementary modes (EMs) which itself is impractical in genome-scale networks. We present MCSEnumerator, a new method for effective enumeration of the smallest MCSs (with fewest interventions) in genome-scale metabolic network models. For this we combine two approaches, namely (i) the mapping of MCSs to EMs in a dual network, and (ii) a modified algorithm by which shortest EMs can be effectively determined in large networks. In this way, we can identify the smallest MCSs by calculating the shortest EMs in the dual network. Realistic application examples demonstrate that our algorithm is able to list thousands of the most efficient intervention strategies in genome-scale networks for various intervention problems. For instance, for the first time we could enumerate all synthetic lethals in E.coli with combinations of up to 5 reactions. We also applied the new algorithm exemplarily to compute strain designs for growth-coupled synthesis of different products (ethanol, fumarate, serine) by E.coli. We found numerous new engineering strategies partially requiring less knockouts and guaranteeing higher product yields (even without the assumption of optimal growth) than reported previously. The strength of the presented approach is that smallest intervention strategies can be quickly calculated and screened with neither network size nor the number of required interventions posing major challenges. PMID:24391481

  9. Application of Intra-Oral Dental Scanners in the Digital Workflow of Implantology

    PubMed Central

    van der Meer, Wicher J.; Andriessen, Frank S.; Wismeijer, Daniel; Ren, Yijin

    2012-01-01

    Intra-oral scanners will play a central role in digital dentistry in the near future. In this study the accuracy of three intra-oral scanners was compared. Materials and methods: A master model made of stone was fitted with three high precision manufactured PEEK cylinders and scanned with three intra-oral scanners: the CEREC (Sirona), the iTero (Cadent) and the Lava COS (3M). In software the digital files were imported and the distance between the centres of the cylinders and the angulation between the cylinders was assessed. These values were compared to the measurements made on a high accuracy 3D scan of the master model. Results: The distance errors were the smallest and most consistent for the Lava COS. The distance errors for the Cerec were the largest and least consistent. All the angulation errors were small. Conclusions: The Lava COS in combination with a high accuracy scanning protocol resulted in the smallest and most consistent errors of all three scanners tested when considering mean distance errors in full arch impressions both in absolute values and in consistency for both measured distances. For the mean angulation errors, the Lava COS had the smallest errors between cylinders 1–2 and the largest errors between cylinders 1–3, although the absolute difference with the smallest mean value (iTero) was very small (0,0529°). An expected increase in distance and/or angular errors over the length of the arch due to an accumulation of registration errors of the patched 3D surfaces could be observed in this study design, but the effects were statistically not significant. Clinical relevance For making impressions of implant cases for digital workflows, the most accurate scanner with the scanning protocol that will ensure the most accurate digital impression should be used. In our study model that was the Lava COS with the high accuracy scanning protocol. PMID:22937030

  10. Genetic composition of captive panda population.

    PubMed

    Yang, Jiandong; Shen, Fujun; Hou, Rong; Da, Yang

    2016-10-03

    A major function of the captive panda population is to preserve the genetic diversity of wild panda populations in their natural habitats. Understanding the genetic composition of the captive panda population in terms of genetic contributions from the wild panda populations provides necessary knowledge for breeding plans to preserve the genetic diversity of the wild panda populations. The genetic contributions from different wild populations to the captive panda population were highly unbalanced, with Qionglai accounting for 52.2 % of the captive panda gene pool, followed by Minshan with 21.5 %, Qinling with 10.6 %, Liangshan with 8.2 %, and Xiaoxiangling with 3.6 %, whereas Daxiangling, which had similar population size as Xiaoxiangling, had no genetic representation in the captive population. The current breeding recommendations may increase the contribution of some small wild populations at the expense of decreasing the contributions of other small wild populations, i.e., increasing the Xiaoxiangling contribution while decreasing the contribution of Liangshan, or sharply increasing the Qinling contribution while decreasing the contributions of Xiaoxiangling and Liangshan, which were two of the three smallest wild populations and were already severely under-represented in the captive population. We developed three habitat-controlled breeding plans that could increase the genetic contributions from the smallest wild populations to 6.7-11.2 % for Xiaoxiangling, 11.5-12.3 % for Liangshan and 12.9-20.0 % for Qinling among the offspring of one breeding season while reducing the risk of hidden inbreeding due to related founders from the same habitat undetectable by pedigree data. The three smallest wild panda populations of Daxiangling, Xiaoxiangling and Liangshan either had no representation or were severely unrepresented in the current captive panda population. By incorporating the breeding goal of increasing the genetic contributions from the smallest wild populations into breeding plans, the severely under-represented small wild populations in the current captive panda population could be increased steadily for the near future.

  11. Physical limits on kinesin-5–mediated chromosome congression in the smallest mitotic spindles

    PubMed Central

    McCoy, Kelsey M.; Tubman, Emily S.; Claas, Allison; Tank, Damien; Clancy, Shelly Applen; O’Toole, Eileen T.; Berman, Judith; Odde, David J.

    2015-01-01

    A characteristic feature of mitotic spindles is the congression of chromosomes near the spindle equator, a process mediated by dynamic kinetochore microtubules. A major challenge is to understand how precise, submicrometer-scale control of kinetochore micro­tubule dynamics is achieved in the smallest mitotic spindles, where the noisiness of microtubule assembly/disassembly will potentially act to overwhelm the spatial information that controls microtubule plus end–tip positioning to mediate congression. To better understand this fundamental limit, we conducted an integrated live fluorescence, electron microscopy, and modeling analysis of the polymorphic fungal pathogen Candida albicans, which contains one of the smallest known mitotic spindles (<1 μm). Previously, ScCin8p (kinesin-5 in Saccharomyces cerevisiae) was shown to mediate chromosome congression by promoting catastrophe of long kinetochore microtubules (kMTs). Using C. albicans yeast and hyphal kinesin-5 (Kip1p) heterozygotes (KIP1/kip1∆), we found that mutant spindles have longer kMTs than wild-type spindles, consistent with a less-organized spindle. By contrast, kinesin-8 heterozygous mutant (KIP3/kip3∆) spindles exhibited the same spindle organization as wild type. Of interest, spindle organization in the yeast and hyphal states was indistinguishable, even though yeast and hyphal cell lengths differ by two- to fivefold, demonstrating that spindle length regulation and chromosome congression are intrinsic to the spindle and largely independent of cell size. Together these results are consistent with a kinesin-5–mediated, length-dependent depolymerase activity that organizes chromosomes at the spindle equator in C. albicans to overcome fundamental noisiness in microtubule self-assembly. More generally, we define a dimensionless number that sets a fundamental physical limit for maintaining congression in small spindles in the face of assembly noise and find that C. albicans operates very close to this limit, which may explain why it has the smallest known mitotic spindle that still manifests the classic congression architecture. PMID:26354423

  12. Summary Diagrams for Coupled Hydrodynamic-Ecosystem Model Skill Assessment

    DTIC Science & Technology

    2009-01-01

    reference point have the smallest unbiased RMSD value (Fig. 3). It would appear that the cluster of model points closest to the reference point may...total RMSD values. This is particularly the case for phyto- plankton absorption (Fig. 3B) where the cluster of points closest to the reference...pattern statistics and the bias (difference of mean values) each magnitude of the total Root-Mean-Square Difference ( RMSD ). An alternative skill score and

  13. Comparison of Ultra-Rapid Orbit Prediction Strategies for GPS, GLONASS, Galileo and BeiDou.

    PubMed

    Geng, Tao; Zhang, Peng; Wang, Wei; Xie, Xin

    2018-02-06

    Currently, ultra-rapid orbits play an important role in the high-speed development of global navigation satellite system (GNSS) real-time applications. This contribution focuses on the impact of the fitting arc length of observed orbits and solar radiation pressure (SRP) on the orbit prediction performance for GPS, GLONASS, Galileo and BeiDou. One full year's precise ephemerides during 2015 were used as fitted observed orbits and then as references to be compared with predicted orbits, together with known earth rotation parameters. The full nine-parameter Empirical Center for Orbit Determination in Europe (CODE) Orbit Model (ECOM) and its reduced version were chosen in our study. The arc lengths of observed fitted orbits that showed the smallest weighted root mean squares (WRMSs) and medians of the orbit differences after a Helmert transformation fell between 40 and 45 h for GPS and GLONASS and between 42 and 48 h for Galileo, while the WRMS values and medians become flat after a 42 h arc length for BeiDou. The stability of the Helmert transformation and SRP parameters also confirmed the similar optimal arc lengths. The range around 42-45 h is suggested to be the optimal arc length interval of the fitted observed orbits for the multi-GNSS joint solution of ultra-rapid orbits.

  14. Sales forecasting newspaper with ARIMA: A case study

    NASA Astrophysics Data System (ADS)

    Permatasari, Carina Intan; Sutopo, Wahyudi; Hisjam, Muh.

    2018-02-01

    People are beginning to switch to using digital media for their daily activities, including changes in newspaper reading patterns to electronic news. In uncertainty trend, the customers of printed newspaper also have switched to electronic news. It has some negative effects on the printed newspaper demand, where there is often an inaccuracy of supply with demand which means that many newspapers are returned. The aim of this paper is to predict printed newspaper demand as accurately as possible to minimize the number of returns, to keep off the missed sales and to restrain the oversupply. The autoregressive integrated moving average (ARIMA) models were adopted to predict the right number of newspapers for a real case study of a newspaper company in Surakarta. The model parameters were found using maximum likelihood method. Then, the software Eviews 9 were utilized to forecasting any particular variables in the newspaper industry. This paper finally presents the appropriate of modeling and sales forecasting newspaper based on the output of the ARIMA models. In particular, it can be recommended to use ARIMA (1, 1, 0) model in predicting the number of newspapers. ARIMA (1, 1, 0) model was chosen from three different models that it provides the smallest value of the mean absolute percentage error (MAPE).

  15. HPC on Competitive Cloud Resources

    NASA Astrophysics Data System (ADS)

    Bientinesi, Paolo; Iakymchuk, Roman; Napper, Jeff

    Computing as a utility has reached the mainstream. Scientists can now easily rent time on large commercial clusters that can be expanded and reduced on-demand in real-time. However, current commercial cloud computing performance falls short of systems specifically designed for scientific applications. Scientific computing needs are quite different from those of the web applications that have been the focus of cloud computing vendors. In this chapter we demonstrate through empirical evaluation the computational efficiency of high-performance numerical applications in a commercial cloud environment when resources are shared under high contention. Using the Linpack benchmark as a case study, we show that cache utilization becomes highly unpredictable and similarly affects computation time. For some problems, not only is it more efficient to underutilize resources, but the solution can be reached sooner in realtime (wall-time). We also show that the smallest, cheapest (64-bit) instance on the studied environment is the best for price to performance ration. In light of the high-contention we witness, we believe that alternative definitions of efficiency for commercial cloud environments should be introduced where strong performance guarantees do not exist. Concepts like average, expected performance and execution time, expected cost to completion, and variance measures--traditionally ignored in the high-performance computing context--now should complement or even substitute the standard definitions of efficiency.

  16. Comparison of Ultra-Rapid Orbit Prediction Strategies for GPS, GLONASS, Galileo and BeiDou

    PubMed Central

    Zhang, Peng; Wang, Wei; Xie, Xin

    2018-01-01

    Currently, ultra-rapid orbits play an important role in the high-speed development of global navigation satellite system (GNSS) real-time applications. This contribution focuses on the impact of the fitting arc length of observed orbits and solar radiation pressure (SRP) on the orbit prediction performance for GPS, GLONASS, Galileo and BeiDou. One full year’s precise ephemerides during 2015 were used as fitted observed orbits and then as references to be compared with predicted orbits, together with known earth rotation parameters. The full nine-parameter Empirical Center for Orbit Determination in Europe (CODE) Orbit Model (ECOM) and its reduced version were chosen in our study. The arc lengths of observed fitted orbits that showed the smallest weighted root mean squares (WRMSs) and medians of the orbit differences after a Helmert transformation fell between 40 and 45 h for GPS and GLONASS and between 42 and 48 h for Galileo, while the WRMS values and medians become flat after a 42 h arc length for BeiDou. The stability of the Helmert transformation and SRP parameters also confirmed the similar optimal arc lengths. The range around 42–45 h is suggested to be the optimal arc length interval of the fitted observed orbits for the multi-GNSS joint solution of ultra-rapid orbits. PMID:29415467

  17. Sensitivity analysis of gene ranking methods in phenotype prediction.

    PubMed

    deAndrés-Galiana, Enrique J; Fernández-Martínez, Juan L; Sonis, Stephen T

    2016-12-01

    It has become clear that noise generated during the assay and analytical processes has the ability to disrupt accurate interpretation of genomic studies. Not only does such noise impact the scientific validity and costs of studies, but when assessed in the context of clinically translatable indications such as phenotype prediction, it can lead to inaccurate conclusions that could ultimately impact patients. We applied a sequence of ranking methods to damp noise associated with microarray outputs, and then tested the utility of the approach in three disease indications using publically available datasets. This study was performed in three phases. We first theoretically analyzed the effect of noise in phenotype prediction problems showing that it can be expressed as a modeling error that partially falsifies the pathways. Secondly, via synthetic modeling, we performed the sensitivity analysis for the main gene ranking methods to different types of noise. Finally, we studied the predictive accuracy of the gene lists provided by these ranking methods in synthetic data and in three different datasets related to cancer, rare and neurodegenerative diseases to better understand the translational aspects of our findings. In the case of synthetic modeling, we showed that Fisher's Ratio (FR) was the most robust gene ranking method in terms of precision for all the types of noise at different levels. Significance Analysis of Microarrays (SAM) provided slightly lower performance and the rest of the methods (fold change, entropy and maximum percentile distance) were much less precise and accurate. The predictive accuracy of the smallest set of high discriminatory probes was similar for all the methods in the case of Gaussian and Log-Gaussian noise. In the case of class assignment noise, the predictive accuracy of SAM and FR is higher. Finally, for real datasets (Chronic Lymphocytic Leukemia, Inclusion Body Myositis and Amyotrophic Lateral Sclerosis) we found that FR and SAM provided the highest predictive accuracies with the smallest number of genes. Biological pathways were found with an expanded list of genes whose discriminatory power has been established via FR. We have shown that noise in expression data and class assignment partially falsifies the sets of discriminatory probes in phenotype prediction problems. FR and SAM better exploit the principle of parsimony and are able to find subsets with less number of high discriminatory genes. The predictive accuracy and the precision are two different metrics to select the important genes, since in the presence of noise the most predictive genes do not completely coincide with those that are related to the phenotype. Based on the synthetic results, FR and SAM are recommended to unravel the biological pathways that are involved in the disease development. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. The Depth of Ice Inside the Smallest Cold-Traps on Mercury: Implications for Age and Origin

    NASA Astrophysics Data System (ADS)

    Rubanenko, L.; Mazarico, E.; Neumann, G. A.; Paige, D. A.

    2018-05-01

    We use Mercury Laser Altimeter data and an illumination model to constrain the depth of the smallest ice deposits on Mercury. By comparing this depth to modeled gardening rates, we estimate the age and delivery method of this ice.

  19. Responsiveness, Sensitivity, and Minimally Detectable Difference of the Graded and Redefined Assessment of Strength, Sensibility, and Prehension, Version 1.0.

    PubMed

    Kalsi-Ryan, Sukhvinder; Beaton, Dorcas; Ahn, Henry; Askes, Heather; Drew, Brian; Curt, Armin; Popovic, Milos R; Wang, Justin; Verrier, Mary C; Fehlings, Michael G

    2016-02-01

    As spinal cord injury (SCI) trials begin to involve subjects with acute cervical SCI, establishing the property of an upper limb outcome measure to detect change over time is critical for its usefulness in clinical trials. The objectives of this study were to define responsiveness, sensitivity, and minimally detectable difference (MDD) of the Graded Redefined Assessment of Strength, Sensibility, and Prehension (GRASSP). An observational, longitudinal study was conducted. International Standards of Neurological Classification of SCI (ISNCSCI), GRASSP, Capabilities of Upper Extremity Questionnaire (CUE-Q), and Spinal Cord Independence Measure (SCIM) were administered 0-10 days, 1, 3, 6, and 12 months post-injury. Standardized Response Means (SRM) for GRASSP and ISNCSCI measures were calculated. Longitudinal construct validity was calculated using Pearson correlation coefficients. Smallest real difference for all subtests was calculated to define the MDD values for all GRASSP subtests. Longitudinal construct validity demonstrated GRASSP and all external measures to be responsive to neurological change for 1 year post-injury. SRM values for the GRASSP subtests ranged from 0.25 to 0.85 units greater than that for ISNCSCI strength and sensation, SCIM-SS, and CUE-Q. MDD values for GRASSP subtests ranged from 2-5 points. GRASSP demonstrates good responsiveness and excellent sensitivity that is superior to ISNCSCI and SCIM III. MDD values are useful in the evaluation of interventions in both clinical and research settings. The responsiveness and sensitivity of GRASSP make it a valuable condition-specific measure in tetraplegia, where changes in upper limb neurological and functional outcomes are essential for evaluating the efficacy of interventions.

  20. Prevalence of Gendered Views of Reading in Thailand and Canada

    ERIC Educational Resources Information Center

    Sokal, Laura

    2010-01-01

    Recent large-scale testing of reading achievement indicates significant gender differences favoring girls in all countries tested, a situation that some researchers believe is the result of boys viewing reading as a feminine activity. Given that Canada has one of the world's smallest gender gaps in reading whereas Thailand has one of the largest,…

  1. Reliability of Metrics Associated with a Counter-Movement Jump Performed on a Force Plate

    ERIC Educational Resources Information Center

    Lombard, Wayne; Reid, Sorrel; Pearson, Keagan; Lambert, Michael

    2017-01-01

    The counter-movement jump is a consequence of maximal force, rate of force developed, and neuromuscular coordination. Thus, the counter-movement jump has been used to monitor various training adaptations. However, the smallest detectable difference of counter-movement jump metrics has yet to be established. The objective of the present study was…

  2. Effects of Cluster Porosity on the Tensile Properties of Butt-Weldments in T-1 Steel

    DTIC Science & Technology

    1974-11-01

    i 12 Boiler and Pressure Vessel Code .19 In this code, the algebraic difference between the largest and smallest principal stresses is defined...Report U1LU- HN(J 7l-2()24 (University ot Illinois. 1971). "Nuclear Power Components.’* ASME Boiler and Pressure Vessel Code . Section HI. Subsections

  3. Pioneering Mars: Turning the Red Planet Green with Earth's Smallest Settlers

    ERIC Educational Resources Information Center

    Cwikla, Julie; Milroy, Scott; Reider, David; Skelton, Tara

    2014-01-01

    Pioneering Mars: Turning the Red Planet Green with the Earth's Smallest Settlers (http://pioneeringmars.org) provides a partnership model for STEM (science, technology, engineering, and mathematics) learning that brings university scientists together with high school students to investigate whether cyanobacteria from Antarctica could survive on…

  4. The influence of study population and definition of improvement on the smallest detectable change and the minimal important change of the neck disability index.

    PubMed

    Schuller, Wouter; Ostelo, Raymond W J G; Janssen, Richard; de Vet, Henrica C W

    2014-04-15

    Reported values of the minimal important change (MIC) and the smallest detectable change (SDC) for the neck disability index (NDI) differ strongly, raising questions about the generalizability of these parameters. The SDC and the MIC are possibly influenced by the study design or by the study population. We studied the influence of the type of anchor, the definition of improvement and population characteristics on the SDC and the MIC of the NDI. A cohort study including 101 patients with non-specific, chronic neck pain. SDC and MIC were calculated using two types of external anchors. For each anchor we applied two different definitions to dichotomize the population into improved and unimproved patients. The influence of patient characteristics was assessed in relevant subgroups: patients with or without radiating pain and patients with different baseline scores. The influence of different anchors and different definitions of improvement on estimates of the SDC and the MIC was only minimal. The SDC and the MIC were similar for subgroups of patients with or without radiation, but differed strongly for subgroups of patients with higher or lower baseline scores. Our study shows that estimates of the SDC and the MIC of the NDI can be influenced by population characteristics. It is concluded that we cannot adopt a single change score to define relevant change by combining the result of previous studies.

  5. Using a smaller plate did not reduce energy intake at meals

    PubMed Central

    Rolls, Barbara J.; Roe, Liane S.; Halverson, Kitti H.; Meengs, Jennifer S.

    2007-01-01

    In three cross-over experiments, we examined the effect on energy intake of changing the size of the plate used at a meal. On separate days, adults were served the same lunch menu but were given a different-sized plate. In the first study, 45 participants used each of three plate sizes (17, 22, or 26 cm) and served the main course from a large dish. In the second study, 30 participants received an equal amount of food presented on each of the two larger plates. In the third study, 44 participants used each of the three plates and selected from a buffet of five foods matched for energy density. Results showed that plate size had no significant effect on energy intake. The mean differences in intake using the smallest and largest plates in the three studies were 21±13 g, 11±13 g, and 4±18 g, respectively, equivalent to < 142 kJ (34 kcal) and not significantly different from zero. Participants in the third study made significantly more trips to the buffet when they were given the smallest plate. These findings show that using a smaller plate did not lead to a reduction in food intake at meals eaten in the laboratory. PMID:17540474

  6. Changes to Articulatory Kinematics in Response to Loudness Cues in Individuals with Parkinson’s Disease

    PubMed Central

    Darling, Meghan; Huber, Jessica E.

    2012-01-01

    Purpose Individuals with Parkinson’s disease (PD) exhibit differences in displacement and velocity of the articulators as compared to older adults. The purpose of the current study was to examine effects of three loudness cues on articulatory movement patterns in individuals with PD. Methods Nine individuals diagnosed with idiopathic PD and 9 age- and sex- matched healthy controls produced sentences in four conditions: 1) comfortable loudness, 2) targeting 10dB above comfortable, 3) twice as loud as comfortable, and 4) in background noise. Lip and jaw kinematics and acoustic measurements were obtained. Results Both groups significantly increased sound pressure level (SPL) in the loud conditions as compared to comfortable. For the loud conditions, both groups had the highest SPL in background noise and 10dB and the lowest in twice as loud. Control participants produced the largest opening displacement in background noise and the smallest in twice as loud. Conversely, individuals with PD produced the largest opening displacement in twice as loud and the smallest in background noise. Conclusions Control participants and individuals with PD responded to cues to increase loudness in different ways. Changes in SPL may explain differences in kinematics for the control participants, but do not for individuals with PD. PMID:21386044

  7. Effect of geometry structure on critical properties

    NASA Astrophysics Data System (ADS)

    Jiang, Qing; Jiang, Xue-fan

    1997-02-01

    The effective-field renormalization group (EFRG) scheme is utilized to compute critical properties of the transverse Ising model (TIM) in a quantum-spin system. We distinguish differences between lattices of the same coordination number but of different structures and take effects of the first fluctuation correction into account. The improved results for the critical transverse field are obtained for several lattice structures even by considering the smallest possible cluster, which is in good agreement with series results.

  8. Adaptive rival penalized competitive learning and combined linear predictor model for financial forecast and investment.

    PubMed

    Cheung, Y M; Leung, W M; Xu, L

    1997-01-01

    We propose a prediction model called Rival Penalized Competitive Learning (RPCL) and Combined Linear Predictor method (CLP), which involves a set of local linear predictors such that a prediction is made by the combination of some activated predictors through a gating network (Xu et al., 1994). Furthermore, we present its improved variant named Adaptive RPCL-CLP that includes an adaptive learning mechanism as well as a data pre-and-post processing scheme. We compare them with some existing models by demonstrating their performance on two real-world financial time series--a China stock price and an exchange-rate series of US Dollar (USD) versus Deutschmark (DEM). Experiments have shown that Adaptive RPCL-CLP not only outperforms the other approaches with the smallest prediction error and training costs, but also brings in considerable high profits in the trading simulation of foreign exchange market.

  9. Utilization of alum sludge as chromium removal

    NASA Astrophysics Data System (ADS)

    Zahari, Nazirul Mubin; Sidek, Lariyah Mohd; Zulkifli, Muhammad Azmeer Asyraf; Hua, Chua Kok; Jalil, Nurulhidayah Abdul

    2017-09-01

    The amount of alum sludge produced at water treatment plant has become a problem where it is highly costly in order to dispose them. Various research was conducted to find the most suitable and economic alternative to recycle and reused of alum sludge. In this study, alum sludge was retrieved from Waterworks where it was dewatered, dried, grounded and sieved to obtain smallest particle sizes of alum sludge. The synthetic water was prepared at the laboratory in as it was used to imitate the properties of real water contaminated with chromium. This study was conducted to determine the percentage reduction of chromium concentration in synthetic water by using alum sludge as absorbent. The percentage reduction of chromium was observed under the effect of initial concentration of chromium and the height of alum sludge. The result indicates that chromium concentration reduction was the highest at the lowest initial concentration and at the highest height of alum sludge and vice versa.

  10. Preparation of calcium hydroxyapatite nanoparticles using microreactor and their characteristics of protein adsorption.

    PubMed

    Kandori, Kazuhiko; Kuroda, Tomohiko; Togashi, Shigenori; Katayama, Erika

    2011-02-03

    The calcium hydroxyapatite Ca(10)(PO(4))(6)(OH)(2) (Hap) nanoparticles were prepared by using microreactor and employed these Hap nanoparticles to clarify the adsorption behavior of proteins. The size of Hap particles produced by the microreactor reduced in the order of a hardness of the reaction conditions for mixing Ca(OH)(2) and H(3)PO(4) aqueous solutions, such as flow rates of both solutions and temperature. Finally, the size of the smallest Hap nanoparticle became 2 × 15 nm(2), similar to that of BSA molecule (4 × 14 nm(2)). It is noteworthy that the smallest Hap nanoparticles still possesses rodlike shape, suggesting that particles are grown along c-axis even though the reactants mixed very rapidly in narrow channels of the microreactors. The X-ray diffraction patterns of the Hap nanoparticles revealed that the crystallinity of the materials produced by the microreactor is low. The FTIR measurement indicated that the Hap nanoparticles produced by microreactor were carbonate-substituted type B Hap, where the carbonate ions replace the phosphate ions in the crystal lattice. All the adsorption isotherms of acidic bovine serum albumin (BSA), neutral myoglobin (MGB), and basic lysozyme (LSZ) onto Hap nanoparticles from 1 × 10(-4) mol/dm(3) KCl solution were the Langmuirian type. The saturated amounts of adsorbed BSA (n(S)(BSA)) for the Hap nanoparticles produced by microreactor were decreased with decrease in the mean particle length, and finally it reduced to zero for the smallest Hap nanoparticles. Similar results were observed for the adsorption of LSZ; the saturated amounts of adsorbed LSZ (n(S)(LSZ)) also reduced to zero for the smallest Hap nanoparticles. However, in the case of MGB, the saturated mounts of adsorbed MGB (n(S)(MGB)) are also depressed with decreased in their particle size, but about half of MGB molecules still adsorbed onto the smallest Hap nanoparticles. This difference in the protein adsorption behavior was explained by the difference in the size and flexibility of three kinds of proteins. The reduction of n(S)(BSA) is due to the decrease in the fraction of C sites on the side face of each Hap nanoparticle; i.e., there is not enough area left on the nanoparticle surface to adsorb large BSA molecules even though the BSA molecules are soft and their conformations are alterable. The reduction of n(S)(LSZ) was explained by the reduction of P sites. Further, rigidity of the LSZ molecules was given another possibility of the depression of n(S)(LSZ) for the Hap nanoparticles. However, MGB molecules with small and soft structure were adsorbed on the Hap nanoparticle surface by changing their conformation. We could control the amounts of adsorbed proteins by changing the particle size of Hap in the nanometer range and kinds of proteins. These obtained results may be useful for developing biomimetic materials for bone grafts and successful surgical devices in the biochemical field.

  11. Comparison of myelination between large and small pig fetuses during late gestation

    USDA-ARS?s Scientific Manuscript database

    We compared myelination of the cerebellum, brain stem, and spinal cord in the largest and smallest pig fetuses within a litter during late gestation. Gilts were killed on days 92, 100, and 110 of gestation and these neural tissues were obtained from the largest and smallest fetuses in each litter. M...

  12. Circumpolar variation in morphological characteristics of Greater White-fronted Geese Anser albifrons

    USGS Publications Warehouse

    Ely, Craig R.; Fox, A.D.; Alisauskas, R.T.; Andreev, A.; Bromley, R.G.; Degtyarev, Andrei G.; Ebbinge, B.; Gurtovaya, E.N.; Kerbes, R.; Kondratyev, Alexander V.; Kostin, I.; Krechmar, A.V.; Litvin, K.E.; Miyabayashi, Y.; Moou, J.H.; Oates, R.M.; Orthmeyer, D.L.; Sabano, Yutaka; Simpson, S.G.; Solovieva, D.V.; Spindler, Michael A.; Syroechkovsky, Y.V.; Takekawa, John Y.; Walsh, A.

    2005-01-01

    Capsule: Greater White-fronted Geese show significant variation in body size from sampling locations throughout their circumpolar breeding range. Aims: To determine the degree of geographical variation in body size of Greater White-fronted Geese and identify factors contributing to any apparent patterns in variation. Methods: Structural measures of >3000 geese from 16 breeding areas throughout the Holarctic breeding range of the species were compared statistically. Results: Palearctic forms varied clinally, and increased in size from the smallest forms on the Kanin and Taimyr peninsulas in western Eurasia to the largest forms breeding in the Anadyr Lowlands of eastern Chukotka. Clinal variation was less apparent in the Nearctic, as both the smallest form in the Nearctic and the largest form overall (the Tule Goose) were from different breeding areas in Alaska. The Tule Goose was 25% larger than the smallest form. Birds from Greenland (A. a. flavirostris) were the second largest, although only slightly larger than geese from several North American populations. Body size was not correlated with breeding latitude but was positively correlated with temperature on the breeding grounds, breeding habitat, and migration distance. Body mass of Greater White-fronted Geese from all populations remained relatively constant during the period of wing moult. Morphological distinctness of eastern and western Palearctic forms concurs with earlier findings of complete range disjunction. Conclusions: Patterns of morphological variation in Greater White-fronted Geese across the Holarctic can be generally attributed to adaptation to variable breeding environments, migration requirements, and phylo-geographical histories. 

  13. The Wor(l)d is a Collage: Multi-Performance by Chinese Heritage Language Speakers

    ERIC Educational Resources Information Center

    He, Agnes Weiyun

    2013-01-01

    This study examines the simultaneous use of English and Chinese by speakers of Chinese as a heritage language (CHL). It focuses on spontaneous, dynamic, and high-density mixing of the two languages within the smallest building block of a speaking turn: the turn constructional unit (TCU). Drawing upon data from different age and proficiency groups,…

  14. Growth data for 29 elevational transect years from the California study of ponderosa pine

    Treesearch

    M. Thompson Conkle

    1973-01-01

    Ponderosa pine progenies from parents restricted in latitude but spanning 7.000 feet of elevation show significant growth differences in plantations at low-, mid-, and high-elevation test sites. At low- and mid-elevation sites tree heights and diameters of progenies from high-elevation parents were the smallest; those from the low-elevation parents, intermediate; and...

  15. Wang and Yau’s quasi-local energy for an extreme Kerr spacetime

    NASA Astrophysics Data System (ADS)

    Miller, Warner A.; Ray, Shannon; Wang, Mu-Tao; Yau, Shing-Tung

    2018-03-01

    There exist constant radial surfaces, S , that may not be globally embeddable in {R}3 for Kerr spacetimes with a>\\sqrt{3}M/2 . To compute the Brown and York (B–Y) quasi-local energy (QLE), one must isometrically embed S into {R}3 . On the other hand, the Wang and Yau (W–Y) QLE embeds S into Minkowski space. In this paper, we examine the W–Y QLE for surfaces that may or may not be globally embeddable in {R}3 . We show that their energy functional, E[τ] , has a critical point at τ=0 for all constant radial surfaces in t=constant hypersurfaces using Boyer–Lindquist coordinates. For τ=0 , the W–Y QLE reduces to the B–Y QLE. To examine the W–Y QLE in these cases, we write the functional explicitly in terms of τ under the assumption that τ is only a function of θ. We then use a Fourier expansion of τ(θ) to explore the values of E[τ(θ)] in the space of coefficients. From our analysis, we discovered an open region of complex values for E[τ(θ)] . We also study the physical properties of the smallest real value of E[τ(θ)] , which lies on the boundary separating real and complex energies.

  16. Multifractal analysis and topological properties of a new family of weighted Koch networks

    NASA Astrophysics Data System (ADS)

    Huang, Da-Wen; Yu, Zu-Guo; Anh, Vo

    2017-03-01

    Weighted complex networks, especially scale-free networks, which characterize real-life systems better than non-weighted networks, have attracted considerable interest in recent years. Studies on the multifractality of weighted complex networks are still to be undertaken. In this paper, inspired by the concepts of Koch networks and Koch island, we propose a new family of weighted Koch networks, and investigate their multifractal behavior and topological properties. We find some key topological properties of the new networks: their vertex cumulative strength has a power-law distribution; there is a power-law relationship between their topological degree and weight strength; the networks have a high weighted clustering coefficient of 0.41004 (which is independent of the scaling factor c) in the limit of large generation t; the second smallest eigenvalue μ2 and the maximum eigenvalue μn are approximated by quartic polynomials of the scaling factor c for the general Laplacian operator, while μ2 is approximately a quartic polynomial of c and μn= 1.5 for the normalized Laplacian operator. Then, we find that weighted koch networks are both fractal and multifractal, their fractal dimension is influenced by the scaling factor c. We also apply these analyses to six real-world networks, and find that the multifractality in three of them are strong.

  17. Single-molecule sequencing of the desiccation-tolerant grass Oropetium thomaeum.

    PubMed

    VanBuren, Robert; Bryant, Doug; Edger, Patrick P; Tang, Haibao; Burgess, Diane; Challabathula, Dinakar; Spittle, Kristi; Hall, Richard; Gu, Jenny; Lyons, Eric; Freeling, Michael; Bartels, Dorothea; Ten Hallers, Boudewijn; Hastie, Alex; Michael, Todd P; Mockler, Todd C

    2015-11-26

    Plant genomes, and eukaryotic genomes in general, are typically repetitive, polyploid and heterozygous, which complicates genome assembly. The short read lengths of early Sanger and current next-generation sequencing platforms hinder assembly through complex repeat regions, and many draft and reference genomes are fragmented, lacking skewed GC and repetitive intergenic sequences, which are gaining importance due to projects like the Encyclopedia of DNA Elements (ENCODE). Here we report the whole-genome sequencing and assembly of the desiccation-tolerant grass Oropetium thomaeum. Using only single-molecule real-time sequencing, which generates long (>16 kilobases) reads with random errors, we assembled 99% (244 megabases) of the Oropetium genome into 625 contigs with an N50 length of 2.4 megabases. Oropetium is an example of a 'near-complete' draft genome which includes gapless coverage over gene space as well as intergenic sequences such as centromeres, telomeres, transposable elements and rRNA clusters that are typically unassembled in draft genomes. Oropetium has 28,466 protein-coding genes and 43% repeat sequences, yet with 30% more compact euchromatic regions it is the smallest known grass genome. The Oropetium genome demonstrates the utility of single-molecule real-time sequencing for assembling high-quality plant and other eukaryotic genomes, and serves as a valuable resource for the plant comparative genomics community.

  18. 19 CFR 122.48a - Electronic information for air cargo required in advance of arrival.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... data for incoming cargo that is listed in paragraph (d)(2) of this section: (i) An Automated Broker... based on the smallest external packing unit (M) (for example, 2 pallets containing 50 pieces each would... quantity based on the smallest external packing unit (M) (for example, 2 pallets containing 50 pieces each...

  19. 19 CFR 122.48a - Electronic information for air cargo required in advance of arrival.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... data for incoming cargo that is listed in paragraph (d)(2) of this section: (i) An Automated Broker... based on the smallest external packing unit (M) (for example, 2 pallets containing 50 pieces each would... quantity based on the smallest external packing unit (M) (for example, 2 pallets containing 50 pieces each...

  20. 19 CFR 122.48a - Electronic information for air cargo required in advance of arrival.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... data for incoming cargo that is listed in paragraph (d)(2) of this section: (i) An Automated Broker... based on the smallest external packing unit (M) (for example, 2 pallets containing 50 pieces each would... quantity based on the smallest external packing unit (M) (for example, 2 pallets containing 50 pieces each...

  1. Adaptations to host infection and larval parasitism in Unionoida

    Treesearch

    Christopher M. Barnhart; Wendell R. Haag; William N. Roston

    2008-01-01

    Freshwater mussel larval parasitism of fish is unique among bivalves. The relationship is primarily phoretic rather than nutritive; only the smallest glochidia and the haustorial larva grow substantially while on the host. Growth of the smallest larvae suggests a lower functional size limit of -150 )um for the juvenile stage. Most Ambleminae, the most diverse North...

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Le, K. C.; Tran, T. M.; Langer, J. S.

    The statistical-thermodynamic dislocation theory developed in previous papers is used here in an analysis of high-temperature deformation of aluminum and steel. Using physics-based parameters that we expect theoretically to be independent of strain rate and temperature, we are able to fit experimental stress-strain curves for three different strain rates and three different temperatures for each of these two materials. Here, our theoretical curves include yielding transitions at zero strain in agreement with experiment. We find that thermal softening effects are important even at the lowest temperatures and smallest strain rates.

  3. Ecological Guild Evolution and the Discovery of the World's Smallest Vertebrate

    PubMed Central

    Rittmeyer, Eric N.; Allison, Allen; Gründler, Michael C.; Thompson, Derrick K.; Austin, Christopher C.

    2012-01-01

    Living vertebrates vary drastically in body size, yet few taxa reach the extremely minute size of some frogs and teleost fish. Here we describe two new species of diminutive terrestrial frogs from the megadiverse hotspot island of New Guinea, one of which represents the smallest known vertebrate species, attaining an average body size of only 7.7 mm. Both new species are members of the recently described genus Paedophryne, the four species of which are all among the ten smallest known frog species, making Paedophryne the most diminutive genus of anurans. This discovery highlights intriguing ecological similarities among the numerous independent origins of diminutive anurans, suggesting that minute frogs are not mere oddities, but represent a previously unrecognized ecological guild. PMID:22253785

  4. High-accuracy mass spectrometry for fundamental studies.

    PubMed

    Kluge, H-Jürgen

    2010-01-01

    Mass spectrometry for fundamental studies in metrology and atomic, nuclear and particle physics requires extreme sensitivity and efficiency as well as ultimate resolving power and accuracy. An overview will be given on the global status of high-accuracy mass spectrometry for fundamental physics and metrology. Three quite different examples of modern mass spectrometric experiments in physics are presented: (i) the retardation spectrometer KATRIN at the Forschungszentrum Karlsruhe, employing electrostatic filtering in combination with magnetic-adiabatic collimation-the biggest mass spectrometer for determining the smallest mass, i.e. the mass of the electron anti-neutrino, (ii) the Experimental Cooler-Storage Ring at GSI-a mass spectrometer of medium size, relative to other accelerators, for determining medium-heavy masses and (iii) the Penning trap facility, SHIPTRAP, at GSI-the smallest mass spectrometer for determining the heaviest masses, those of super-heavy elements. Finally, a short view into the future will address the GSI project HITRAP at GSI for fundamental studies with highly-charged ions.

  5. A PDMS microfiber Mach-Zehnder interferometer and determination of nanometer displacements

    NASA Astrophysics Data System (ADS)

    Martincek, Ivan; Kacik, Daniel

    2018-01-01

    A polydimethylsiloxane (PDMS) microfiber Mach-Zehnder interferometer (MZI), integrated between single-mode optical fibers (SMFs), is proposed and demonstrated experimentally. One arm of the interferometer consists of a microfiber of diameter 7 μm and length 270 μm; the second is an air arm. Due to the good elastic properties of PDMS microfiber, the length of the air arm of MZI can be changed by changing the distance between SMFs. The change in length of the air arm results in a change in the transmission characteristics of the MZI; thus, the relative displacement can be measured in the range 10-250 nm. By measuring the peak-to-peak amplitude of the difference in transmission powers (in dB), the smallest displacement by prepared MZI was determined as being on the order of a few nm for a ratio of intensities of 0.135. For a higher ratio of intensities of transmission functions, the smallest displacement could be determined on the order of subnanometers.

  6. Comparison of several inflow control devices for flight simulation of fan tone noise using a JT15D-1 engine

    NASA Technical Reports Server (NTRS)

    Mcardle, J. G.; Jones, W. L.; Heidelberg, L. J.; Homyak, L.

    1980-01-01

    To enable accurate simulation of in-flight fan tone noise during ground static tests, four devices intended to reduce inflow disturbances and turbulence were tested with a JT15D-1 turbofan engine. These inflow control devices (ICD's) consisted of honeycomb/screen structures mounted over the engine inlet. The ICD's ranged from 1.6 to 4 fan diameters in size, and differed in shape and fabrication method. All the ICD's significantly reduced the BPF tone in the far-field directivity patterns, but the smallest ICD's apparently introduced propagating modes which could be recognized by additional lobes in the speeds; at supersonic fan tip speed the smallest ICD's had some measurable loss, but the largest had no loss. Data from a typical transducer show that the unsteady inflow distortion modes (turbulence) were eliminated or significantly reduced when either of the ICD's was installed. However, some steady inflow distortion modes remained.

  7. Au279(SR)84: The Smallest Gold Thiolate Nanocrystal That Is Metallic and the Birth of Plasmon.

    PubMed

    Sakthivel, Naga Arjun; Stener, Mauro; Sementa, Luca; Fortunelli, Alessandro; Ramakrishna, Guda; Dass, Amala

    2018-03-15

    We report a detailed study on the optical properties of Au 279 (SR) 84 using steady-state and transient absorption measurements to probe its metallic nature, time-dependent density functional theory (TDDFT) studies to correlate the optical spectra, and density of states (DOS) to reveal the factors governing the origin of the collective surface plasmon resonance (SPR) oscillation. Au 279 is the smallest identified gold nanocrystal to exhibit SPR. Its optical absorption exhibits SPR at 510 nm. Power-dependent bleach recovery kinetics of Au 279 suggests that electron dynamics dominates its relaxation and it can support plasmon oscillations. Interestingly, TDDFT and DOS studies with different tail group residues (-CH 3 and -Ph) revealed the important role played by the tail groups of ligands in collective oscillation. Also, steady-state and time-resolved absorption for Au 36 , Au 44 , and Au 133 were studied to reveal the molecule-to-metal evolution of aromatic AuNMs. The optical gap and transient decay lifetimes decrease as the size increases.

  8. Dropwise condensation

    PubMed Central

    Leach, R. N.; Stevens, F.; Langford, S. C.; Dickinson, J. T.

    2008-01-01

    Dropwise condensation of water vapor from a naturally cooling, hot water reservoir onto a hydrophobic polymer film and a silanized glass slide was studied by direct observation and simulations. The observed drop growth kinetics suggest that smallest drops grow principally by the diffusion of water adsorbed on the substrate to the drop perimeter, while drops larger than 50 μm in diameter grow principally by direct deposition from the vapor onto the drop surface. Drop coalescence plays a critical role in determining the drop size distribution, and stimulates the nucleation of new, small drops on the substrates. Simulations of drop growth incorporating these growth mechanisms provide a good description of the observed drop size distribution. Because of the large role played by coalescence, details of individual drop growth make little difference to the final drop size distribution. The rate of condensation per unit substrate area is especially high for the smallest drops, and may help account for the high heat transfer rates associated with dropwise condensation relative to filmwise condensation in heat exchange applications. PMID:17014129

  9. Image processing for improved eye-tracking accuracy

    NASA Technical Reports Server (NTRS)

    Mulligan, J. B.; Watson, A. B. (Principal Investigator)

    1997-01-01

    Video cameras provide a simple, noninvasive method for monitoring a subject's eye movements. An important concept is that of the resolution of the system, which is the smallest eye movement that can be reliably detected. While hardware systems are available that estimate direction of gaze in real-time from a video image of the pupil, such systems must limit image processing to attain real-time performance and are limited to a resolution of about 10 arc minutes. Two ways to improve resolution are discussed. The first is to improve the image processing algorithms that are used to derive an estimate. Off-line analysis of the data can improve resolution by at least one order of magnitude for images of the pupil. A second avenue by which to improve resolution is to increase the optical gain of the imaging setup (i.e., the amount of image motion produced by a given eye rotation). Ophthalmoscopic imaging of retinal blood vessels provides increased optical gain and improved immunity to small head movements but requires a highly sensitive camera. The large number of images involved in a typical experiment imposes great demands on the storage, handling, and processing of data. A major bottleneck had been the real-time digitization and storage of large amounts of video imagery, but recent developments in video compression hardware have made this problem tractable at a reasonable cost. Images of both the retina and the pupil can be analyzed successfully using a basic toolbox of image-processing routines (filtering, correlation, thresholding, etc.), which are, for the most part, well suited to implementation on vectorizing supercomputers.

  10. Evaluating the effect of database inflation in proteogenomic search on sensitive and reliable peptide identification.

    PubMed

    Li, Honglan; Joh, Yoon Sung; Kim, Hyunwoo; Paek, Eunok; Lee, Sang-Won; Hwang, Kyu-Baek

    2016-12-22

    Proteogenomics is a promising approach for various tasks ranging from gene annotation to cancer research. Databases for proteogenomic searches are often constructed by adding peptide sequences inferred from genomic or transcriptomic evidence to reference protein sequences. Such inflation of databases has potential of identifying novel peptides. However, it also raises concerns on sensitive and reliable peptide identification. Spurious peptides included in target databases may result in underestimated false discovery rate (FDR). On the other hand, inflation of decoy databases could decrease the sensitivity of peptide identification due to the increased number of high-scoring random hits. Although several studies have addressed these issues, widely applicable guidelines for sensitive and reliable proteogenomic search have hardly been available. To systematically evaluate the effect of database inflation in proteogenomic searches, we constructed a variety of real and simulated proteogenomic databases for yeast and human tandem mass spectrometry (MS/MS) data, respectively. Against these databases, we tested two popular database search tools with various approaches to search result validation: the target-decoy search strategy (with and without a refined scoring-metric) and a mixture model-based method. The effect of separate filtering of known and novel peptides was also examined. The results from real and simulated proteogenomic searches confirmed that separate filtering increases the sensitivity and reliability in proteogenomic search. However, no one method consistently identified the largest (or the smallest) number of novel peptides from real proteogenomic searches. We propose to use a set of search result validation methods with separate filtering, for sensitive and reliable identification of peptides in proteogenomic search.

  11. SU-D-201-04: Study On the Impact of Tumor Shape and Size On Drug Delivery to Pancreatic Tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Soltani, M; Bazmara, H; Sefidgar, M

    Purpose: Drug delivery to solid tumors can be expressed physically using transport phenomena such as convection and diffusion for the drug of interest within extracellular matrices. We aimed to carefully model these phenomena, and to investigate the effect of tumor shape and size on drug delivery to solid tumors in the pancreas. Methods: In this study, multiple tumor geometries as obtained from clinical PET/CT images were considered. An advanced numerical method was used to simultaneously solve fluid flow and solute transport equations. Data from n=45 pancreatic cancer patients with non-resectable locoregional disease were analyzed, and geometrical information from the tumorsmore » including size, shape, and aspect ratios were classified. To investigate effect of tumor shape, tumors with similar size but different shapes were selected and analyzed. Moreover, to investigate effect of tumor size, tumors with similar shapes but different sizes, ranging from 1 to 77 cm{sup 3}, were selected and analyzed. A hypothetical tumor similar to one of the analyzed tumors, but scaled to reduce its size below 0.2 cm{sup 3}, was also analyzed. Results: The results showed relatively similar average drug concentration profiles in tumors with different sizes. Generally, smaller tumors had higher absolute drug concentration. In the hypothetical tumor, with volume less than 0.2 cm{sup 3}, the average drug concentration was 20% higher in comparison to its counterparts. For the various real tumor geometries, however, the maximum difference between average drug concentrations was 10% for the smallest and largest tumors. Moreover, the results demonstrated that for pancreatic tumors the shape is not significant. The negligible difference of drug concentration in different tumor shapes was due to the minimum effect of convection in pancreatic tumors. Conclusion: In tumors with different sizes, smaller tumors have higher drug delivery; however, the impact of tumor shape in the case of pancreatic tumors is not significant.« less

  12. Effect of opacifiers and UV absorbers on pigmented maxillofacial silicone elastomer, part 1: color stability after artificial aging.

    PubMed

    Han, Ying; Powers, John M; Kiat-Amnuay, Sudarat

    2013-06-01

    Much dissatisfaction with the color instability and reduced lifetime of extraoral maxillofacial prostheses due to degradation has been reported. The purpose of this study was to compare the effect of a UV mineral-based light protecting agent (LP) on the color stability of pigmented maxillofacial silicone elastomer MDX-4210/Type A after artificial aging to 2 widely used opacifiers. Forty-five groups were established (n=225 total). Three different types of opacifiers (LP, titanium white dry pigment [TW], or silicone intrinsic white [SW]) were added to silicone MDX-4210/type A at 3 concentrations (5%, 10%, or 15%) and subsequently combined with each of 5 colors (no pigments [control], red, blue, yellow, or mixed pigments). Artists' oil pigment was used with LP and TW, while intrinsic silicone pigment was used to color SW. Before and after an energy exposure of 450 kJ/m(2), CIE L*a*b* values were measured with a spectrophotometer. The CIELAB 50:50% perceptibility (ΔE*=1.1) and acceptability threshold (ΔE*=3.0) were used to interpret color changes (ΔE*). Color differences after aging were subjected to 3-way ANOVA. Means were compared by the Fisher PLSD intervals at α=.05. The ΔE* values of all groups were below the acceptability threshold of ΔE*=3.0, except for the control group of SW at 10%, which showed the greatest color change (ΔE*=3.1). When mixed pigment groups were considered, at 5% concentration, LP showed the smallest color change, followed by SW and TW (P<.05); at 10%, no significant differences among the 3 opacifiers were noted (P>.05); at 15%, LP showed the smallest color change, followed by TW and SW (P<.05). All 3 opacifiers at all concentrations protected pigmented silicone MDX4-4210/Type A from color degradation. The LP group showed the smallest color changes. Copyright © 2013 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  13. 46 CFR 172.090 - Intact transverse stability.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... righting arm curve must be at least 5 foot-degrees (1.52 meter-degrees) up to the smallest of the following... least 10 foot-degrees (3.05 meter-degrees) up to the smallest of the following angles: (i) The angle of... service, the area under the righting arm curve must be at least 15 foot-degrees (4.57 meter-degrees) up to...

  14. 46 CFR 172.090 - Intact transverse stability.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... righting arm curve must be at least 5 foot-degrees (1.52 meter-degrees) up to the smallest of the following... least 10 foot-degrees (3.05 meter-degrees) up to the smallest of the following angles: (i) The angle of... service, the area under the righting arm curve must be at least 15 foot-degrees (4.57 meter-degrees) up to...

  15. 46 CFR 172.090 - Intact transverse stability.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... righting arm curve must be at least 5 foot-degrees (1.52 meter-degrees) up to the smallest of the following... least 10 foot-degrees (3.05 meter-degrees) up to the smallest of the following angles: (i) The angle of... service, the area under the righting arm curve must be at least 15 foot-degrees (4.57 meter-degrees) up to...

  16. 46 CFR 172.090 - Intact transverse stability.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... righting arm curve must be at least 5 foot-degrees (1.52 meter-degrees) up to the smallest of the following... least 10 foot-degrees (3.05 meter-degrees) up to the smallest of the following angles: (i) The angle of... service, the area under the righting arm curve must be at least 15 foot-degrees (4.57 meter-degrees) up to...

  17. 46 CFR 172.090 - Intact transverse stability.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... righting arm curve must be at least 5 foot-degrees (1.52 meter-degrees) up to the smallest of the following... least 10 foot-degrees (3.05 meter-degrees) up to the smallest of the following angles: (i) The angle of... service, the area under the righting arm curve must be at least 15 foot-degrees (4.57 meter-degrees) up to...

  18. Energy Efficiency and Sustainability of Different Building Structures in Latvian Climate

    NASA Astrophysics Data System (ADS)

    Jakovičs, A.; Gendelis, S.; Bandeniece, L.

    2015-11-01

    Five experimental test buildings have been built in Riga, Latvia. They are identical except external walls for which different mainly regional building materials are used. Calculated U-values of the other walls, floor and ceiling are the same for each test building. Initial moisture influences the relative humidity of indoor air, which can be higher in the initial time period; as a result, heat transmittances are also very different and cause different heating/cooling energy consumption. Overheating risk in summer exists for test buildings with the smallest thermal inertia. Both summer and heating seasons have been analysed and differences between five test houses have been discussed in details.

  19. Rivaling the World's Smallest Reptiles: Discovery of Miniaturized and Microendemic New Species of Leaf Chameleons (Brookesia) from Northern Madagascar

    PubMed Central

    Glaw, Frank; Köhler, Jörn; Townsend, Ted M.; Vences, Miguel

    2012-01-01

    Background One clade of Malagasy leaf chameleons, the Brookesia minima group, is known to contain species that rank among the smallest amniotes in the world. We report on a previously unrecognized radiation of these miniaturized lizards comprising four new species described herein. Methodology/Principal Findings The newly discovered species appear to be restricted to single, mostly karstic, localities in extreme northern Madagascar: Brookesia confidens sp. n. from Ankarana, B. desperata sp. n. from Forêt d'Ambre, B. micra sp. n. from the islet Nosy Hara, and B. tristis sp. n. from Montagne des Français. Molecular phylogenetic analyses based on one mitochondrial and two nuclear genes of all nominal species in the B. minima group congruently support that the four new species, together with B. tuberculata from Montagne d'Ambre in northern Madagascar, form a strongly supported clade. This suggests that these species have diversified in geographical proximity in this small area. All species of the B. minima group, including the four newly described ones, are characterized by very deep genetic divergences of 18–32% in the ND2 gene and >6% in the 16S rRNA gene. Despite superficial similarities among all species of this group, their status as separate evolutionary lineages is also supported by moderate to strong differences in external morphology, and by clear differences in hemipenis structure. Conclusion/Significance The newly discovered dwarf chameleon species represent striking cases of miniaturization and microendemism and suggest the possibility of a range size-body size relationship in Malagasy reptiles. The newly described Brookesia micra reaches a maximum snout-vent length in males of 16 mm, and its total length in both sexes is less than 30 mm, ranking it among the smallest amniote vertebrates in the world. With a distribution limited to a very small islet, this species may represent an extreme case of island dwarfism. PMID:22348069

  20. WE-G-204-08: Optimized Digital Radiographic Technique for Lost Surgical Devices/Needle Identification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gorman, A; Seabrook, G; Brakken, A

    Purpose: Small surgical devices and needles are used in many surgical procedures. Conventionally, an x-ray film is taken to identify missing devices/needles if post procedure count is incorrect. There is no data to indicate smallest surgical devices/needles that can be identified with digital radiography (DR), and its optimized acquisition technique. Methods: In this study, the DR equipment used is a Canon RadPro mobile with CXDI-70c wireless DR plate, and the same DR plate on a fixed Siemens Multix unit. Small surgical devices and needles tested include Rubber Shod, Bulldog, Fogarty Hydrogrip, and needles with sizes 3-0 C-T1 through 8-0 BV175-6.more » They are imaged with PMMA block phantoms with thickness of 2–8 inch, and an abdomen phantom. Various DR techniques are used. Images are reviewed on the portable x-ray acquisition display, a clinical workstation, and a diagnostic workstation. Results: all small surgical devices and needles are visible in portable DR images with 2–8 inch of PMMA. However, when they are imaged with the abdomen phantom plus 2 inch of PMMA, needles smaller than 9.3 mm length can not be visualized at the optimized technique of 81 kV and 16 mAs. There is no significant difference in visualization with various techniques, or between mobile and fixed radiography unit. However, there is noticeable difference in visualizing the smallest needle on a diagnostic reading workstation compared to the acquisition display on a portable x-ray unit. Conclusion: DR images should be reviewed on a diagnostic reading workstation. Using optimized DR techniques, the smallest needle that can be identified on all phantom studies is 9.3 mm. Sample DR images of various small surgical devices/needles available on diagnostic workstation for comparison may improve their identification. Further in vivo study is needed to confirm the optimized digital radiography technique for identification of lost small surgical devices and needles.« less

  1. TU-F-BRE-08: Significant Variations in Measured Small Cone Output Factor for FFF Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sudhyadhom, A; Ma, L; Kirby, N

    2014-06-15

    Purpose: To evaluate the measurement accuracy of several dosimeters for small cone output factors in two SRS/SBRT dedicated systems with Flattening Filter Free (FFF) beams: a Varian TrueBeam STx (TB) and an Accuray CyberKnife VSI (CK). Output factors (OFs) were measured for both machines and for CK, compared against a Monte Carlo model. Methods: Dose measurements were taken using three different FFF beams (TB 6XFFF, TB 10XFFF, and CK 6XFFF). Three commonly used types of dosimeters were examined in this work: a micro-ion chamber (Exradin A16), two shielded diodes (PTW TN60008 and PTW TN60017), and radiochromic film (Gafchromic EBT2). Measuredmore » OFs from these dosimeters were compared with each other and OFs measured with an Exradin W1 scintillator. Monte Carlo determined correction factors for the CK beam for the micro-ion chamber and diodes were applied to the respective OF measurements and compared against scintillator measured OFs corrected for volume averaging. Results: OFs measured for the smallest fields using the micro-ion chamber, diodes, scintillator, and film varied substantially (with up to a 16% difference between dosimeters). Micro-ion chamber and film OF measurements were up to 9% and 10%, respectively, lower than scintillator measurements for the smallest fields. OF measurements by diode were up to 6% greater than scintillator measurements for the smallest fields. With correction factors, the micro-ion chamber and diode measured OFs showed good agreement with scintillator measured OFs for the CK 6XFFF beam (within 3% and 1.5%, respectively). Conclusion: Uncorrected small field OFs vary significantly with dosimeter. The accuracy of scintillator measurements for small field OFs may be greater than the other dosimeters studied in this work (when uncorrected). Measurements involving EBT2 film may Result in lower accuracy for smaller fields (less than 10mm). Care should be taken in the choice of the dosimeter used for small field OF measurements.« less

  2. Detecting and collecting traces of semen and blood from outdoor crime scenes using crime scene dogs and presumptive tests.

    PubMed

    Skalleberg, A G; Bouzga, M M

    2016-07-01

    In 2009, the Norwegian police academy educated their first crime scene dogs, trained to locate traces of seminal fluid and blood in outdoor and indoor crime scenes. The Department of Forensic Biology was invited to take part in this project to educate the police in specimen collection and presumptive testing. We performed tests where seminal fluid was deposited on different outdoor surfaces from between one hour to six days, and blood on coniferous ground from between one hour to two days. For both body fluids the tests were performed with three different volumes. The crime scene dogs located the stains, and acid phosphatase/tetrabasebariumperoxide was used as presumptive tests before collection for microscopy and DNA analysis. For seminal fluid the dogs were able to locate all stains for up to two days and only the largest volume after four days. The presumptive tests confirmed the dog's detection. By microscopy we were able to detect spermatozoa for the smallest volumes up to 32h, and for the largest volume up to 4 days, and the DNA results are in correlation to these findings. For blood all the stains were detected by the dogs, except the smallest volume of blood after 32h. The presumptive tests confirmed the dog's detection. We were able to get DNA results for most stains in the timeframe 1-48h with the two largest volumes. The smallest volume shows diversities between the parallels, with no DNA results after 24h. These experiments show that it is critical that body fluids are collected within a timeframe to be able to get a good DNA result, preferably within the first 24-48h. Other parameters that should be taken into account are the weather conditions, type of surfaces and specimen collection. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  3. A comparison of three federal datasets for thermoelectric water withdrawals in the United States for 2010

    USGS Publications Warehouse

    Harris, Melissa A.; Diehl, Timothy H.

    2017-01-01

    Historically, thermoelectric water withdrawal has been estimated by the Energy Information Administration (EIA) and the U.S. Geological Survey's (USGS) water-use compilations. Recently, the USGS developed models for estimating withdrawal at thermoelectric plants to provide estimates independent from plant operator-reported withdrawal data. This article compares three federal datasets of thermoelectric withdrawals for the United States in 2010: one based on the USGS water-use compilation, another based on EIA data, and the third based on USGS model-estimated data. The withdrawal data varied widely. Many plants had three different withdrawal values, and for approximately 54% of the plants the largest withdrawal value was twice the smallest, or larger. The causes of discrepancies among withdrawal estimates included definitional differences, definitional noise, and various nondefinitional causes. The uncertainty in national totals can be characterized by the range among the three datasets, from 5,640 m3/s (129 billion gallons per day [bgd]) to 6,954 m3/s (158 bgd), or by the aggregate difference between the smallest and largest values at each plant, from 4,014 m3/s (92 bgd) to 8,590 m3/s (196 bgd). When used to assess the accuracy of reported values, the USGS model estimates identify plants that need to be reviewed.

  4. Is suicide assessment harmful to participants? Findings from a randomized controlled trial.

    PubMed

    Harris, Keith M; Goh, Melissa Ting-Ting

    2017-04-01

    There is considerable debate on whether suicide assessment carries an iatrogenic risk for participants/patients. A double-blind randomized controlled trial (registration: R000022314) tested the emotional impact of suicide assessment on participants (n = 259) randomly assigned to experimental (n = 122) or control conditions (n = 137). The experimental condition included the Suicidal Affect-Behavior-Cognition Scale and intensive death-related questions, the control condition a quality of life scale. Both included measures of depression, social support and loneliness. Affective states were assessed immediately before and after testing, and research biases minimized. Post-test debriefing interviews collected qualitative reactions. Experimental participants ranged from nonsuicidal to highly suicidal. Between-groups ANCOVAs and repeated measures ANOVAs showed no differences by study condition, and no pre-post-test affect changes for either condition or suicidal participants (P > 0.10), supporting the null hypothesis of no iatrogenic effects. However, depressive participants in both conditions showed significant decreases in positive affect (P < 0.05). Smallest real difference (SRD) scores approximated clinically meaningful differences and showed 20% of participants had a significant positive survey reaction, 24% a negative reaction, with the rest neutral. Linear regressions revealed depressive symptoms and perceived family support, but not suicidality or other factors, predicted negative affect changes, which was supported by qualitative findings. Social desirability bias was also found in qualitative survey responses. No evidence of iatrogenic effects of suicide assessment were found. Recommendations are made to counter possible negative assessment effects on depressive participants/patients, and nurses and other caregivers are encouraged to talk to patients about suicidal symptoms. © 2016 Australian College of Mental Health Nurses Inc.

  5. Size-related cytotoxicological aspects of polyvinylpyrrolidone-capped platinum nanoparticles.

    PubMed

    Buchtelova, Hana; Dostalova, Simona; Michalek, Petr; Krizkova, Sona; Strmiska, Vladislav; Kopel, Pavel; Hynek, David; Richtera, Lukas; Ridoskova, Andrea; Adam, Pavlina; Kynicky, Jindrich; Brtnicky, Martin; Heger, Zbynek; Adam, Vojtech

    2017-07-01

    The nanotechnological concept is based on size-dependent properties of particles in the 1-100 nm range. Nevertheless, the connection between their size and effect is still not clear. Thus, we focused on reductive colloidal synthesis, characterization and biological testing of Pt nanoparticles (PtNPs) capped with biocompatible polymer polyvinylpyrrolidone (PVP). Synthesized PtNPs were of 3 different primary sizes (approx. ∼10; ∼14 and > 20 nm) and demonstrated exceptional haemocompatibility. In vitro treatment of three different types of malignant cells (prostate - LNCaP, breast - MDA-MB-231 and neuroblastoma - GI-ME-N) revealed that even marginal differences in PtNPs diameter resulted in changes in their cytotoxicity. The highest cytotoxicity was observed using the smallest PtNPs-10, where 24IC 50 was lower (3.1-6.2 μg/mL) than for cisplatin (8.1-19.8 μg/mL). In contrast to MDA-MB-231 and LNCaP cells, in GI-ME-N cells PtNPs caused noticeable changes in their cellular structure without influencing their viability. Post-exposure analyses revealed that PtNPs-29 and PtNPs-40 were capable of forming considerably higher amount of reactive oxygen species with consequent stimulation of expression of metallothionein (MT1/2 and MT3), at both mRNA and protein level. Overall, our pilot study demonstrates that in the nanoscaled world even the smallest differences can have crucial biological effect. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Chromosome sizes of phytoplasmas composing major phylogenetic groups and subgroups.

    PubMed

    Marcone, C; Neimark, H; Ragozzino, A; Lauer, U; Seemüller, E

    1999-09-01

    ABSTRACT Chromosome sizes of 71 phytoplasmas belonging to 12 major phylogenetic groups including several of the aster yellows subgroups were estimated from electrophoretic mobilities of full-length chromosomes in pulsed-field gels. Considerable variation in genome size, from 660 to 1,130 kilobases (kb), was observed among aster yellows phytoplasmas. Chromosome size heterogeneity was also observed in the stolbur phytoplasma group (range 860 to 1,350 kb); in this group, isolate STOLF contains the largest chromosome found in a phytoplasma to date. A wide range of chromosome sizes, from 670 to 1,075 kb, was also identified in the X-disease group. The other phytoplasmas examined, which included members of the apple proliferation, Italian alfalfa witches' broom, faba bean phyllody, pigeon pea witches' broom, sugarcane white leaf, Bermuda grass white leaf, ash yellows, clover proliferation, and elm yellows groups, all have chromosomes smaller than 1 megabase, and the size ranges within each of these groups is narrower than in the aster yellows, stolbur, and X-disease groups. The smallest chromosome, approximately 530 kb, was found in two Bermuda grass white leaf phytoplasma isolates. This not only is the smallest mollicute chromosome found to date, but also is the smallest chromosome known for any cell. More than one large DNA band was observed in several phytoplasma preparations. Possible explanations for the occurrence of more than one band may be infection of the host plant by different phytoplasmas, the presence of more than one chromosome in the same organism, or the presence of large extrachromosomal DNA elements.

  7. Assessment study of lichenometric methods for dating surfaces

    NASA Astrophysics Data System (ADS)

    Jomelli, Vincent; Grancher, Delphine; Naveau, Philippe; Cooley, Daniel; Brunstein, Daniel

    2007-04-01

    In this paper, we discuss the advantages and drawbacks of the most classical approaches used in lichenometry. In particular, we perform a detailed comparison among methods based on the statistical analysis of either the largest lichen diameters recorded on geomorphic features or the frequency of all lichens. To assess the performance of each method, a careful comparison design with well-defined criteria is proposed and applied to two distinct data sets. First, we study 350 tombstones. This represents an ideal test bed because tombstone dates are known and, therefore, the quality of the estimated lichen growth curve can be easily tested for the different techniques. Secondly, 37 moraines from two tropical glaciers are investigated. This analysis corresponds to our real case study. For both data sets, we apply our list of criteria that reflects precision, error measurements and their theoretical foundations when proposing estimated ages and their associated confidence intervals. From this comparison, it clearly appears that two methods, the mean of the n largest lichen diameters and the recent Bayesian method based on extreme value theory, offer the most reliable estimates of moraine and tombstones dates. Concerning the spread of the error, the latter approach provides the smallest uncertainty and it is the only one that takes advantage of the statistical nature of the observations by fitting an extreme value distribution to the largest diameters.

  8. A Proposed Approach for Joint Modeling of the Longitudinal and Time-To-Event Data in Heterogeneous Populations: An Application to HIV/AIDS's Disease.

    PubMed

    Roustaei, Narges; Ayatollahi, Seyyed Mohammad Taghi; Zare, Najaf

    2018-01-01

    In recent years, the joint models have been widely used for modeling the longitudinal and time-to-event data simultaneously. In this study, we proposed an approach (PA) to study the longitudinal and survival outcomes simultaneously in heterogeneous populations. PA relaxes the assumption of conditional independence (CI). We also compared PA with joint latent class model (JLCM) and separate approach (SA) for various sample sizes (150, 300, and 600) and different association parameters (0, 0.2, and 0.5). The average bias of parameters estimation (AB-PE), average SE of parameters estimation (ASE-PE), and coverage probability of the 95% confidence interval (CP) among the three approaches were compared. In most cases, when the sample sizes increased, AB-PE and ASE-PE decreased for the three approaches, and CP got closer to the nominal level of 0.95. When there was a considerable association, PA in comparison with SA and JLCM performed better in the sense that PA had the smallest AB-PE and ASE-PE for the longitudinal submodel among the three approaches for the small and moderate sample sizes. Moreover, JLCM was desirable for the none-association and the large sample size. Finally, the evaluated approaches were applied on a real HIV/AIDS dataset for validation, and the results were compared.

  9. Predicting Visual Distraction Using Driving Performance Data

    PubMed Central

    Kircher, Katja; Ahlstrom, Christer

    2010-01-01

    Behavioral variables are often used as performance indicators (PIs) of visual or internal distraction induced by secondary tasks. The objective of this study is to investigate whether visual distraction can be predicted by driving performance PIs in a naturalistic setting. Visual distraction is here defined by a gaze based real-time distraction detection algorithm called AttenD. Seven drivers used an instrumented vehicle for one month each in a small scale field operational test. For each of the visual distraction events detected by AttenD, seven PIs such as steering wheel reversal rate and throttle hold were calculated. Corresponding data were also calculated for time periods during which the drivers were classified as attentive. For each PI, means between distracted and attentive states were calculated using t-tests for different time-window sizes (2 – 40 s), and the window width with the smallest resulting p-value was selected as optimal. Based on the optimized PIs, logistic regression was used to predict whether the drivers were attentive or distracted. The logistic regression resulted in predictions which were 76 % correct (sensitivity = 77 % and specificity = 76 %). The conclusion is that there is a relationship between behavioral variables and visual distraction, but the relationship is not strong enough to accurately predict visual driver distraction. Instead, behavioral PIs are probably best suited as complementary to eye tracking based algorithms in order to make them more accurate and robust. PMID:21050615

  10. Measurement of the rotational misfit and implant-abutment gap of all-ceramic abutments.

    PubMed

    Garine, Wael N; Funkenbusch, Paul D; Ercoli, Carlo; Wodenscheck, Joseph; Murphy, William C

    2007-01-01

    The specific aims of this study were to measure the implant and abutment hexagonal dimensions, to measure the rotational misfit between implant and abutments, and to correlate the dimension of the gap present between the abutment and implant hexagons with the rotational misfit of 5 abutment-implant combinations from 2 manufacturers. Twenty new externally hexed implants (n = 10 for Nobel Biocare; n = 10 for Biomet/3i) and 50 new abutments were used (n = 10; Procera Zirconia; Procera Alumina; Esthetic Ceramic Abutment; ZiReal; and GingiHue post ZR Zero Rotation abutments). The mating surfaces of all implants and abutments were imaged with a scanning electron microscope before and after rotational misfit measurements. The distances between the corners and center of the implant and abutment hexagon were calculated by entering their x and y coordinates, measured on a measuring microscope, into Pythagoras' theorem. The dimensional difference between abutment and implant hexagons was calculated and correlated with the rotational misfit, which was recorded using a precision optical encoder. Each abutment was rotated (3 times/session) clockwise and counterclockwise until binding. Analysis of variance and Student-Newman-Keuls tests were used to compare rotational misfit among groups (alpha = .05). With respect to rotational misfit, the abutment groups were significantly different from one another (P < .001), with the exception of the Procera Zirconia and Esthetic Ceramic groups (P = .4). The mean rotational misfits in degrees were 4.13 +/- 0.68 for the Procera Zirconia group, 3.92 +/- 0.62 for the Procera Alumina group, 4.10 +/- 0.67 for the Esthetic Ceramic group, 3.48 +/- 0.40 for the ZiReal group, and 1.61 +/- 0.24 for the GingiHue post ZR group. There was no correlation between the mean implant-abutment gap and rotational misfit. Within the limits of this study, machining inconsistencies of the hexagons were found for all implants and abutments tested. The GingiHue Post showed the smallest rotational misfit. All-ceramic abutments without a metal collar showed a greater rotational misfit than those with a metal collar.

  11. Reliability of capturing foot parameters using digital scanning and the neutral suspension casting technique

    PubMed Central

    2011-01-01

    Background A clinical study was conducted to determine the intra and inter-rater reliability of digital scanning and the neutral suspension casting technique to measure six foot parameters. The neutral suspension casting technique is a commonly utilised method for obtaining a negative impression of the foot prior to orthotic fabrication. Digital scanning offers an alternative to the traditional plaster of Paris techniques. Methods Twenty one healthy participants volunteered to take part in the study. Six casts and six digital scans were obtained from each participant by two raters of differing clinical experience. The foot parameters chosen for investigation were cast length (mm), forefoot width (mm), rearfoot width (mm), medial arch height (mm), lateral arch height (mm) and forefoot to rearfoot alignment (degrees). Intraclass correlation coefficients (ICC) with 95% confidence intervals (CI) were calculated to determine the intra and inter-rater reliability. Measurement error was assessed through the calculation of the standard error of the measurement (SEM) and smallest real difference (SRD). Results ICC values for all foot parameters using digital scanning ranged between 0.81-0.99 for both intra and inter-rater reliability. For neutral suspension casting technique inter-rater reliability values ranged from 0.57-0.99 and intra-rater reliability values ranging from 0.36-0.99 for rater 1 and 0.49-0.99 for rater 2. Conclusions The findings of this study indicate that digital scanning is a reliable technique, irrespective of clinical experience, with reduced measurement variability in all foot parameters investigated when compared to neutral suspension casting. PMID:21375757

  12. The impact of arbitrarily applicable relational responding on evaluative learning about hypothetical money and shock outcomes.

    PubMed

    Dymond, Simon; Molet, Mikael; Davies, Lynette

    2017-08-01

    Evaluative learning comprises changes in preferences after co-occurrences between conditioned stimuli (CSs) and an unconditioned stimulus (US) of affective value. Co-occurrences may involve relational responding. Two experiments examined the impact of arbitrary relational responding on evaluative preferences for hypothetical money and shock outcomes. In Experiment 1, participants were trained to make arbitrary relational responses by placing CSs of the same size but different colours into boxes and were then instructed that these CSs represented different intensities of hypothetical USs (money or shock). Liking ratings of the CSs were altered in accordance with the underlying bigger/smaller than relations. A reversal of preference was also observed: the CS associated with the smallest hypothetical shock was rated more positively than the CS associated with the smallest amount of hypothetical money. In Experiment 2, procedures from Relational Frame Theory (RFT) established a relational network of more than/less than relations consisting of five CSs (A-B-C-D-E). Overall, evaluative preferences were altered, but not reversed, depending on (a) how stimuli had been related to one another during the learning phase and (b) whether those stimuli referred to money or shocks. The contribution of RFT to evaluative learning research is discussed.

  13. A different approach on the onset of separation in the flow around a circular cylinder

    NASA Astrophysics Data System (ADS)

    Malamataris, Nikolaos; Sarris, I.; Pazis, D.; Liakos, A.

    2016-11-01

    The onset of separation in the flow around a cylinder is revisited with new insight. The goal of the research is to compute the smallest Reynolds number where the separation actual occurs rather than computing small eddies and extrapolating to the value of the Reynolds number where separation may occur. To this purpose, an accurate home made code is designed with Galerkin finite elements. The computational domain is chosen as the laboratory experiments by Taneda. It is found that in all six different choices of Taneda's diameters of the cylinders he used, separation is not observed for Re < 6 . 1 . Actually, separation is computed in all of his six cases for Re = 6 . 14 . Images of this smallest eddy are shown for the first time where all characteristics of eddies are recognisable (vortex centre, separation length etc). The vorticity of the flow is computed along the cylinder surface and it is shown that, at separation, vorticity changes sign. Byproducts of this research is the computation of the drag coefficient for Reynolds numbers starting from 1 .10-5 up to 40. In addition, the separation angle (point where vorticity changes sign) is computed for 6 . 14 <= Re <= 40 . This research aims to be the most thorough work done on that subject so far.

  14. Comparison of Conventional Methods and Laser-Assisted Rapid Prototyping for Manufacturing Fixed Dental Prostheses: An In Vitro Study.

    PubMed

    Pompa, Giorgio; Di Carlo, Stefano; De Angelis, Francesca; Cristalli, Maria Paola; Annibali, Susanna

    2015-01-01

    This study assessed whether there are differences in marginal fit between laser-fusion and conventional techniques to produce fixed dental prostheses (FDPs). A master steel die with 2 abutments was produced to receive a posterior 4-unit FDPs and single copings. These experimental models were divided into three groups (n = 20/group) manufactured: group 1, Ni-Cr alloy, with a lost-wax casting technique; group 2, Co-Cr alloy, with selective laser melting (SLM); and group 3, yttria-tetragonal zirconia polycrystal (Y-TZP), with a milling system. All specimens were cut along the longitudinal axis and their adaptation was measured at the marginal and shoulder areas on the right and left sides of each abutment. Measurements were made using a stereomicroscope (×60 magnification) and a scanning electron microscope (×800 magnification). The data were analyzed using one-way analysis of variance and the Bonferroni post hoc test, with a significance cutoff of 5%. Significant differences (P < 0.05) were observed between group 3 and the other groups. The marginal opening was smallest with Co-Cr alloy substructures, while the shoulder opening was smallest with Ni-Cr alloy substructures. Within the limitations of this study, the marginal fit of an FDP is better with rapid prototyping (RP) via SLM than conventional manufacturing systems.

  15. Massachusetts Institute of Technology Lincoln Laboratory Journal Volume 6, Number 1, Spring 1993

    DTIC Science & Technology

    1993-01-01

    simple examples, we see that fractal size e goes to zero. The smallest meaningful % amLe of dimension clearly has the potential to discriminate the box...dataset. Figure 13 is an example of this dataset; it value at different resolutions means different num- shows a river with treelined banks (the river is...each bank . The smooth green areas are open fields. ntc~’:F ( ,𔄀 Fj R A6 . 43 - KREITHEN ET AL. Di,,rtmmating lar’qeit fnom (C/utter The remainder of

  16. Short-term test-retest-reliability of conditioned pain modulation using the cold-heat-pain method in healthy subjects and its correlation to parameters of standardized quantitative sensory testing.

    PubMed

    Gehling, Julia; Mainka, Tina; Vollert, Jan; Pogatzki-Zahn, Esther M; Maier, Christoph; Enax-Krumova, Elena K

    2016-08-05

    Conditioned Pain Modulation (CPM) is often used to assess human descending pain inhibition. Nine different studies on the test-retest-reliability of different CPM paradigms have been published, but none of them has investigated the commonly used heat-cold-pain method. The results vary widely and therefore, reliability measures cannot be extrapolated from one CPM paradigm to another. Aim of the present study was to analyse the test-retest-reliability of the common heat-cold-pain method and its correlation to pain thresholds. We tested the short-term test-retest-reliability within 40 ± 19.9 h using a cold-water immersion (10 °C, left hand) as conditioning stimulus (CS) and heat pain (43-49 °C, pain intensity 60 ± 5 on the 101-point numeric rating scale, right forearm) as test stimulus (TS) in 25 healthy right-handed subjects (12females, 31.6 ± 14.1 years). The TS was applied 30s before (TSbefore), during (TSduring) and after (TSafter) the 60s CS. The difference between the pain ratings for TSbefore and TSduring represents the early CPM-effect, between TSbefore and TSafter the late CPM-effect. Quantitative sensory testing (QST, DFNS protocol) was performed on both sessions before the CPM assessment. paired t-tests, Intraclass correlation coefficient (ICC), standard error of measurement (SEM), smallest real difference (SRD), Pearson's correlation, Bland-Altman analysis, significance level p < 0.05 with Bonferroni correction for multiple comparisons, when necessary. Pain ratings during CPM correlated significantly (ICC: 0.411…0.962) between both days, though ratings for TSafter were lower on day 2 (p < 0.005). The early (day 1: 16.7 ± 11.7; day 2: 19.5 ± 11.9; ICC: 0.618, SRD: 20.2) and late (day 1: 1.7 ± 9.2; day 2: 7.6 ± 11.5; ICC: 0.178, SRD: 27.0) CPM effect did not differ significantly between both days. Both early and late CPM-effects did not correlate with the pain thresholds. The short-term test-retest-reliability of the early CPM-effect using the heat-cold-pain method in healthy subjects achieved satisfying results in terms of the ICC. The SRD of the early CPM effect showed that an individual change of > 20 NRS can be attributed to a real change rather than chance. The late CPM-effect was weaker and not reliable.

  17. Ranging in Human Sonar: Effects of Additional Early Reflections and Exploratory Head Movements

    PubMed Central

    Wallmeier, Ludwig; Wiegrebe, Lutz

    2014-01-01

    Many blind people rely on echoes from self-produced sounds to assess their environment. It has been shown that human subjects can use echolocation for directional localization and orientation in a room, but echo-acoustic distance perception - e.g. to determine one's position in a room - has received little scientific attention, and systematic studies on the influence of additional early reflections and exploratory head movements are lacking. This study investigates echo-acoustic distance discrimination in virtual echo-acoustic space, using the impulse responses of a real corridor. Six blindfolded sighted subjects and a blind echolocation expert had to discriminate between two positions in the virtual corridor, which differed by their distance to the front wall, but not to the lateral walls. To solve this task, participants evaluated echoes that were generated in real time from self-produced vocalizations. Across experimental conditions, we systematically varied the restrictions for head rotations, the subjects' orientation in virtual space and the reference position. Three key results were observed. First, all participants successfully solved the task with discrimination thresholds below 1 m for all reference distances (0.75–4 m). Performance was best for the smallest reference distance of 0.75 m, with thresholds around 20 cm. Second, distance discrimination performance was relatively robust against additional early reflections, compared to other echolocation tasks like directional localization. Third, free head rotations during echolocation can improve distance discrimination performance in complex environmental settings. However, head movements do not necessarily provide a benefit over static echolocation from an optimal single orientation. These results show that accurate distance discrimination through echolocation is possible over a wide range of reference distances and environmental conditions. This is an important functional benefit of human echolocation, which may also play a major role in the calibration of auditory space representations. PMID:25551226

  18. Primed low-frequency repetitive transcranial magnetic stimulation and constraint-induced movement therapy in pediatric hemiparesis: a randomized controlled trial.

    PubMed

    Gillick, Bernadette T; Krach, Linda E; Feyma, Tim; Rich, Tonya L; Moberg, Kelli; Thomas, William; Cassidy, Jessica M; Menk, Jeremiah; Carey, James R

    2014-01-01

    The aim of this study was to determine the feasibility and efficacy of five treatments of 6 Hz primed, low-frequency, repetitive transcranial magnetic stimulation (rTMS) combined with constraint-induced movement therapy (CIMT) to promote recovery of the paretic hand in children with congenital hemiparesis. Nineteen children with congenital hemiparesis aged between 8 and 17 years (10 males, nine females; mean age 10 years 10 months, SD 2 years 10 months; Manual Ability Classification Scale levels I-III) underwent five sessions of either real rTMS (n=10) or sham rTMS (n=9) alternated daily with CIMT. CIMT consisted of 13 days of continuous long-arm casting with five skin-check sessions. Each child received a total of 10 hours of one-to-one therapy. The primary outcome measure was the Assisting Hand Assessment (AHA) and the secondary outcome variables were the Canadian Occupational Performance Measure (COPM) and stereognosis. A Wilcoxon signed-rank sum test was used to analyze differences between pre- and post-test scores within the groups. Analysis of covariance was used to compute mean differences between groups adjusting for baseline. Fisher's exact test was used to compare individual change in AHA raw scores with the smallest detectable difference (SDD) of 4 points. All participants receiving treatment finished the study. Improvement in AHA differed significantly between groups (p=0.007). No significant differences in the secondary outcome measures were found. Eight out of 10 participants in the rTMS/CIMT group showed improvement greater than the SDD, but only two out of nine in the sham rTMS/CIMT group showed such improvement (p=0.023). No serious adverse events occurred. Primed, low-frequency rTMS combined with CIMT appears to be safe, feasible, and efficacious in pediatric hemiparesis. Larger clinical trials are now indicated. © 2013 Mac Keith Press.

  19. Aerosol Emissions from Fuse-Deposition Modeling 3D Printers in a Chamber and in Real Indoor Environments.

    PubMed

    Vance, Marina E; Pegues, Valerie; Van Montfrans, Schuyler; Leng, Weinan; Marr, Linsey C

    2017-09-05

    Three-dimensional (3D) printers are known to emit aerosols, but questions remain about their composition and the fundamental processes driving emissions. The objective of this work was to characterize the aerosol emissions from the operation of a fuse-deposition modeling 3D printer. We modeled the time- and size-resolved emissions of submicrometer aerosols from the printer in a chamber study, gained insight into the chemical composition of emitted aerosols using Raman spectroscopy, and measured the potential for exposure to the aerosols generated by 3D printers under real-use conditions in a variety of indoor environments. The average aerosol emission rates ranged from ∼10 8 to ∼10 11 particles min -1 , and the rates varied over the course of a print job. Acrylonitrile butadiene styrene (ABS) filaments generated the largest number of aerosols, and wood-infused polylactic acid (PLA) filaments generated the smallest amount. The emission factors ranged from 6 × 10 8 to 6 × 10 11 per gram of printed part, depending on the type of filament used. For ABS, the Raman spectra of the filament and the printed part were indistinguishable, while the aerosol spectra lacked important peaks corresponding to styrene and acrylonitrile, which are both present in ABS. This observation suggests that aerosols are not a result of volatilization and subsequent nucleation of ABS or direct release of ABS aerosols.

  20. Single-molecule sequencing of the desiccation-tolerant grass Oropetium thomaeum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    VanBuren, Robert; Bryant, Doug; Edger, Patrick P.

    Plant genomes, and eukaryotic genomes in general, are typically repetitive, polyploid and heterozygous, which complicates genome assembly1. The short read lengths of early Sanger and current next-generation sequencing platforms hinder assembly through complex repeat regions, and many draft and reference genomes are fragmented, lacking skewed GC and repetitive intergenic sequences, which are gaining importance due to projects like the Encyclopedia of DNA Elements (ENCODE). Here we report the whole-genome sequencing and assembly of the desiccation-tolerant grass Oropetium thomaeum. Using only single-molecule real-time sequencing, which generates long (>16 kilobases) reads with random errors, we assembled 99% (244 megabases) of the Oropetiummore » genome into 625 contigs with an N50 length of 2.4 megabases. Oropetium is an example of a ‘near-complete’ draft genome which includes gapless coverage over gene space as well as intergenic sequences such as centromeres, telomeres, transposable elements and rRNA clusters that are typically unassembled in draft genomes. Oropetium has 28,466 protein-coding genes and 43% repeat sequences, yet with 30% more compact euchromatic regions it is the smallest known grass genome. As a result, the Oropetium genome demonstrates the utility of single-molecule real-time sequencing for assembling high-quality plant and other eukaryotic genomes, and serves as a valuable resource for the plant comparative genomics community.« less

  1. Single-molecule sequencing of the desiccation-tolerant grass Oropetium thomaeum

    DOE PAGES

    VanBuren, Robert; Bryant, Doug; Edger, Patrick P.; ...

    2015-11-11

    Plant genomes, and eukaryotic genomes in general, are typically repetitive, polyploid and heterozygous, which complicates genome assembly1. The short read lengths of early Sanger and current next-generation sequencing platforms hinder assembly through complex repeat regions, and many draft and reference genomes are fragmented, lacking skewed GC and repetitive intergenic sequences, which are gaining importance due to projects like the Encyclopedia of DNA Elements (ENCODE). Here we report the whole-genome sequencing and assembly of the desiccation-tolerant grass Oropetium thomaeum. Using only single-molecule real-time sequencing, which generates long (>16 kilobases) reads with random errors, we assembled 99% (244 megabases) of the Oropetiummore » genome into 625 contigs with an N50 length of 2.4 megabases. Oropetium is an example of a ‘near-complete’ draft genome which includes gapless coverage over gene space as well as intergenic sequences such as centromeres, telomeres, transposable elements and rRNA clusters that are typically unassembled in draft genomes. Oropetium has 28,466 protein-coding genes and 43% repeat sequences, yet with 30% more compact euchromatic regions it is the smallest known grass genome. As a result, the Oropetium genome demonstrates the utility of single-molecule real-time sequencing for assembling high-quality plant and other eukaryotic genomes, and serves as a valuable resource for the plant comparative genomics community.« less

  2. High Temporal and Spatial Resolution Coverage of Earth from Commercial AVSTAR Systems in Geostationary Orbit

    NASA Astrophysics Data System (ADS)

    Lecompte, M. A.; Heaps, J. F.; Williams, F. H.

    Imaging the earth from Geostationary Earth Orbit (GEO) allows frequent updates of environmental conditions within an observable hemisphere at time and spatial scales appropriate to the most transient observable terrestrial phenomena. Coverage provided by current GEO Meteorological Satellites (METSATS) fails to fully exploit this advantage due primarily to obsolescent technology and also institutional inertia. With the full benefit of GEO based imaging unrealized, rapidly evolving phenomena, occurring at the smallest spatial and temporal scales that frequently have significant environmental impact remain unobserved. These phenomena may be precursors for the most destructive natural processes that adversely effect society. Timely distribution of information derived from "real-time" observations thus may provide opportunities to mitigate much of the damage to life and property that would otherwise occur. AstroVision International's AVStar Earth monitoring system is designed to overcome the current limitations if GEO Earth coverage and to provide real time monitoring of changes to the Earth's complete atmospheric, land and marine surface environments including fires, volcanic events, lightning and meteoritic events on a "live," true color, and multispectral basis. The understanding of severe storm dynamics and its coupling to the earth's electro-sphere will be greatly enhanced by observations at unprecedented sampling frequencies and spatial resolution. Better understanding of these natural phenomena and AVStar operational real-time coverage may also benefit society through improvements in severe weather prediction and warning. AstroVision's AVStar system, designed to provide this capability with the first of a constellation of GEO- based commercial environmental monitoring satellites to be launched in late 2003 will be discussed, including spatial and temporal resolution, spectral coverage with applications and an inventory of the potential benefits to society, science, commerce and education.

  3. The Smallest R/V: A Small-scale Ocean Exploration Demonstration of Real-time Bathymetric Measurements

    NASA Astrophysics Data System (ADS)

    Howell, S. M.; Boston, B.; Maher, S. M.; Sleeper, J. D.; Togia, H.; Tree, J. P.

    2014-12-01

    In October 2013, graduate student members of the University of Hawaii Geophysical Society designed a small-scale model research vessel (R/V) that uses sonar to create 3D maps of a model seafloor in real-time. This pilot project was presented to the public at the School of Ocean and Earth Science and Technology's (SOEST) Biennial Open House weekend. An estimated 7,600 people attended the two-day event, including children and teachers from Hawaii's schools, home school students, community groups, families, and science enthusiasts. Our exhibit demonstrated real-time sonar mapping of a cardboard volcano using a toy size research vessel on a fixed 2D model ship track suspended above a model seafloor. Sound wave travel times were recorded using an unltrasonic emitter/receiver attached to an Arduino microcontroller platform, while the same system measured displacement along the ship track. This data was streamed through a USB connection to a PC running MatLab, where a 3D model was updated as the ship collected data. Our exhibit demonstrates the practical use of complicated concepts, like wave physics and data processing, in a way that even the youngest elementary students are able to understand. It provides an accessible avenue to learn about sonar mapping, and could easily be adapted to talk about bat and marine mammal echolocation by replacing the model ship and volcano. The exhibit received an overwhelmingly positive response from attendees, and has inspired the group to develop a more interactive model for future exhibitions, using multiple objects to be mapped that participants could arrange, and a more robust ship movement system that participants could operate.

  4. Implementation and preliminary evaluation of 'C-tone': A novel algorithm to improve lexical tone recognition in Mandarin-speaking cochlear implant users.

    PubMed

    Ping, Lichuan; Wang, Ningyuan; Tang, Guofang; Lu, Thomas; Yin, Li; Tu, Wenhe; Fu, Qian-Jie

    2017-09-01

    Because of limited spectral resolution, Mandarin-speaking cochlear implant (CI) users have difficulty perceiving fundamental frequency (F0) cues that are important to lexical tone recognition. To improve Mandarin tone recognition in CI users, we implemented and evaluated a novel real-time algorithm (C-tone) to enhance the amplitude contour, which is strongly correlated with the F0 contour. The C-tone algorithm was implemented in clinical processors and evaluated in eight users of the Nurotron NSP-60 CI system. Subjects were given 2 weeks of experience with C-tone. Recognition of Chinese tones, monosyllables, and disyllables in quiet was measured with and without the C-tone algorithm. Subjective quality ratings were also obtained for C-tone. After 2 weeks of experience with C-tone, there were small but significant improvements in recognition of lexical tones, monosyllables, and disyllables (P < 0.05 in all cases). Among lexical tones, the largest improvements were observed for Tone 3 (falling-rising) and the smallest for Tone 4 (falling). Improvements with C-tone were greater for disyllables than for monosyllables. Subjective quality ratings showed no strong preference for or against C-tone, except for perception of own voice, where C-tone was preferred. The real-time C-tone algorithm provided small but significant improvements for speech performance in quiet with no change in sound quality. Pre-processing algorithms to reduce noise and better real-time F0 extraction would improve the benefits of C-tone in complex listening environments. Chinese CI users' speech recognition in quiet can be significantly improved by modifying the amplitude contour to better resemble the F0 contour.

  5. Active plasmonics in WDM traffic switching applications

    NASA Astrophysics Data System (ADS)

    Papaioannou, Sotirios; Kalavrouziotis, Dimitrios; Vyrsokinos, Konstantinos; Weeber, Jean-Claude; Hassan, Karim; Markey, Laurent; Dereux, Alain; Kumar, Ashwani; Bozhevolnyi, Sergey I.; Baus, Matthias; Tekin, Tolga; Apostolopoulos, Dimitrios; Avramopoulos, Hercules; Pleros, Nikos

    2012-09-01

    With metal stripes being intrinsic components of plasmonic waveguides, plasmonics provides a ``naturally'' energy-efficient platform for merging broadband optical links with intelligent electronic processing, instigating a great promise for low-power and small-footprint active functional circuitry. The first active Dielectric-Loaded Surface Plasmon Polariton (DLSPP) thermo-optic (TO) switches with successful performance in single-channel 10 Gb/s data traffic environments have led the inroad towards bringing low-power active plasmonics in practical traffic applications. In this article, we introduce active plasmonics into Wavelength Division Multiplexed (WDM) switching applications, using the smallest TO DLSPP-based Mach-Zehnder interferometric switch reported so far and showing its successful performance in 4×10 Gb/s low-power and fast switching operation. The demonstration of the WDM-enabling characteristics of active plasmonic circuits with an ultra-low power × response time product represents a crucial milestone in the development of active plasmonics towards real telecom and datacom applications, where low-energy and fast TO operation with small-size circuitry is targeted.

  6. Decomposing the permeability spectra of nanocrystalline finemet core

    NASA Astrophysics Data System (ADS)

    Varga, Lajos K.; Kovac, Jozef

    2018-04-01

    In this paper we present a theoretical and experimental investigation on the magnetization contributions to permeability spectra of normal annealed Finemet core with round type hysteresis curve. Real and imaginary parts of the permeability were determined as a function of exciting magnetic field (HAC) between 40 Hz -110 MHz using an Agilent 4294A type Precision Impedance Analyzer. The amplitude of the exciting field was below and around the coercive field of the sample. The spectra were decomposed using the Levenberg-Marquardt algorithm running under Origin 9 software in four contributions: i) eddy current; ii) Debye relaxation of magnetization rotation, iii) Debye relaxation of damped domain wall motion and iv) resonant type DW motion. For small exciting amplitudes the first two components dominate. The last two contributions connected to the DW appear for relative large HAC only, around the coercive force. All the contributions will be discussed in detail accentuating the role of eddy current that is not negligible even for the smallest applied exciting field.

  7. Study report on laser storage and retrieval of image data

    NASA Technical Reports Server (NTRS)

    Becker, C. H.

    1976-01-01

    The theoretical foundation is presented for a system of real-time nonphotographic and nonmagnetic digital laser storage and retrieval of image data. The system utilizes diffraction-limited laser focusing upon thin metal films, melting elementary holes in the metal films in laser focus. The metal films are encapsulated in rotating flexible mylar discs which act as the permanent storage carries. Equal sized holes encompass two dimensional digital ensembles of information bits which are time-sequentially (bit by bit) stored and retrieved. The bits possess the smallest possible size, defined by the Rayleigh criterion of coherent physical optics. Space and time invariant reflective read-out of laser discs with a small laser, provides access to the stored digital information. By eliminating photographic and magnetic data processing, which characterize the previous state of the art, photographic grain, diffusion, and gamma-distortion do not exist. Similarly, magnetic domain structures, magnetic gaps, and magnetic read-out are absent with a digital laser disc system.

  8. Acetylene measurement in flames by chirp-based quantum cascade laser spectrometry.

    PubMed

    Quine, Zachary R; McNesby, Kevin L

    2009-06-01

    We have designed and characterized a mid-IR spectrometer built around a pulsed distributed-feedback quantum cascade laser using the characteristic frequency down-chirp to scan through the spectral region 6.5 cm(-1) spectral region. The behavior of this chirp is extensively measured. The accuracy and detection limits of the system as an absorption spectrometer are demonstrated first by measuring spectra of acetylene through a single pass 16 cm absorption cell in real time at low concentrations and atmospheric pressure. The smallest detectable peak is measured to be approximately 1.5 x 10(-4) absorbance units, yielding a minimum detectable concentration length product of 2.4 parts per million meter at standard temperature and pressure. This system is then used to detect acetylene within an ethylene-air opposed flow flame. Measurements of acetylene content as a function of height above the fuel source are presented, as well as measurements of acetylene produced in fuel breakdown as a function of preinjection fuel temperature.

  9. Spatial vision processes: From the optical image to the symbolic structures of contour information

    NASA Technical Reports Server (NTRS)

    Jobson, Daniel J.

    1988-01-01

    The significance of machine and natural vision is discussed together with the need for a general approach to image acquisition and processing aimed at recognition. An exploratory scheme is proposed which encompasses the definition of spatial primitives, intrinsic image properties and sampling, 2-D edge detection at the smallest scale, the construction of spatial primitives from edges, and the isolation of contour information from textural information. Concepts drawn from or suggested by natural vision at both perceptual and physiological levels are relied upon heavily to guide the development of the overall scheme. The scheme is intended to provide a larger context in which to place the emerging technology of detector array focal-plane processors. The approach differs from many recent efforts in edge detection and image coding by emphasizing smallest scale edge detection as a foundation for multi-scale symbolic processing while diminishing somewhat the importance of image convolutions with multi-scale edge operators. Cursory treatments of information theory illustrate that the direct application of this theory to structural information in images could not be realized.

  10. The smallest quaternary ammonium salts with ether groups for high-performance electrochemical double layer capacitors† †Electronic supplementary information (ESI) available. See DOI: 10.1039/c5sc02755a Click here for additional data file.

    PubMed Central

    Han, Taihee; Park, Min-Sik; Kim, Jeonghun; Kim, Jung Ho

    2016-01-01

    Electrochemical double layer capacitors (EDLCs) are energy storage devices that have been used for a wide range of electronic applications. In particular, the electrolyte is one of the important components, directly related to the capacitance and stability. Herein, we first report a series of the smallest quaternary ammonium salts (QASs), with ether groups on tails and tetrafluoroborate (BF4) as an anion, for use in EDLCs. To find the optimal structure, various QASs with different sized head groups and ether-containing tail groups were systematically compared. Comparing two nearly identical structures with and without ether groups, QASs with oxygen atoms showed improved capacitance, proving that ions with oxygen atoms move more easily than their counterparts at lower electric fields. Moreover, the ether containing QASs showed low activation energy values of conductivities, leading to smaller IR drops during the charge and discharge processes, resulting in an overall higher capacitance. PMID:28959391

  11. Exponent and scrambling index of double alternate circular snake graphs

    NASA Astrophysics Data System (ADS)

    Rahmayanti, Sri; Pasaribu, Valdo E.; Nasution, Sawaluddin; Liani Salnaz, Sishi

    2018-01-01

    A graph is primitive if it contains a cycle of odd length. The exponent of a primitive graph G, denoted by exp(G), is the smallest positive integer k such that for each pair of vertices u and v in G there is a uv-walk length k. The scrambling index of a primitive graph G, denoted by k(G), is the smallest positive integer k such that for each pair of vertices u and v in G there is a uv-walk of length 2k. For an even positive integer n and an odd positive integer r, a (n,r)-double alternate circular snake graph, denoted by DA(C r,n ), is a graph obtained from a path u 1 u 2 ... u n by replacing each edge of the form u 2i u 2i+1 by two different r-cycles. We study the exponent and scrambling index of DA(C r,n ) and show that exp(DA(C r,n )) = n + r - 4 and k(DA(C r,n )) = (n + r - 3)/2.

  12. Vector autoregressive model approach for forecasting outflow cash in Central Java

    NASA Astrophysics Data System (ADS)

    hoyyi, Abdul; Tarno; Maruddani, Di Asih I.; Rahmawati, Rita

    2018-05-01

    Multivariate time series model is more applied in economic and business problems as well as in other fields. Applications in economic problems one of them is the forecasting of outflow cash. This problem can be viewed globally in the sense that there is no spatial effect between regions, so the model used is the Vector Autoregressive (VAR) model. The data used in this research is data on the money supply in Bank Indonesia Semarang, Solo, Purwokerto and Tegal. The model used in this research is VAR (1), VAR (2) and VAR (3) models. Ordinary Least Square (OLS) is used to estimate parameters. The best model selection criteria use the smallest Akaike Information Criterion (AIC). The result of data analysis shows that the AIC value of VAR (1) model is equal to 42.72292, VAR (2) equals 42.69119 and VAR (3) equals 42.87662. The difference in AIC values is not significant. Based on the smallest AIC value criteria, the best model is the VAR (2) model. This model has satisfied the white noise assumption.

  13. On the Time Scale of Nocturnal Boundary Layer Cooling in Valleys and Basins and over Plains

    NASA Astrophysics Data System (ADS)

    de Wekker, Stephan F. J.; Whiteman, C. David

    2006-06-01

    Sequences of vertical temperature soundings over flat plains and in a variety of valleys and basins of different sizes and shapes were used to determine cooling-time-scale characteristics in the nocturnal stable boundary layer under clear, undisturbed weather conditions. An exponential function predicts the cumulative boundary layer cooling well. The fitting parameter or time constant in the exponential function characterizes the cooling of the valley atmosphere and is equal to the time required for the cumulative cooling to attain 63.2% of its total nighttime value. The exponential fit finds time constants varying between 3 and 8 h. Calculated time constants are smallest in basins, are largest over plains, and are intermediate in valleys. Time constants were also calculated from air temperature measurements made at various heights on the sidewalls of a small basin. The variation with height of the time constant exhibited a characteristic parabolic shape in which the smallest time constants occurred near the basin floor and on the upper sidewalls of the basin where cooling was governed by cold-air drainage and radiative heat loss, respectively.

  14. Route to the Smallest Doped Semiconductor: Mn(2+)-Doped (CdSe)13 Clusters.

    PubMed

    Yang, Jiwoong; Fainblat, Rachel; Kwon, Soon Gu; Muckel, Franziska; Yu, Jung Ho; Terlinden, Hendrik; Kim, Byung Hyo; Iavarone, Dino; Choi, Moon Kee; Kim, In Young; Park, Inchul; Hong, Hyo-Ki; Lee, Jihwa; Son, Jae Sung; Lee, Zonghoon; Kang, Kisuk; Hwang, Seong-Ju; Bacher, Gerd; Hyeon, Taeghwan

    2015-10-14

    Doping semiconductor nanocrystals with magnetic transition-metal ions has attracted fundamental interest to obtain a nanoscale dilute magnetic semiconductor, which has unique spin exchange interaction between magnetic spin and exciton. So far, the study on the doped semiconductor NCs has usually been conducted with NCs with larger than 2 nm because of synthetic challenges. Herein, we report the synthesis and characterization of Mn(2+)-doped (CdSe)13 clusters, the smallest doped semiconductors. In this study, single-sized doped clusters are produced in large scale. Despite their small size, these clusters have semiconductor band structure instead of that of molecules. Surprisingly, the clusters show multiple excitonic transitions with different magneto-optical activities, which can be attributed to the fine structure splitting. Magneto-optically active states exhibit giant Zeeman splittings up to elevated temperatures (128 K) with large g-factors of 81(±8) at 4 K. Our results present a new synthetic method for doped clusters and facilitate the understanding of doped semiconductor at the boundary of molecules and quantum nanostructure.

  15. Stationary and oscillatory bound states of dissipative solitons created by third-order dispersion

    NASA Astrophysics Data System (ADS)

    Sakaguchi, Hidetsugu; Skryabin, Dmitry V.; Malomed, Boris A.

    2018-06-01

    We consider the model of fiber-laser cavities near the zero-dispersion point, based on the complex Ginzburg-Landau equation with the cubic-quintic nonlinearity, including the third-order dispersion (TOD) term. It is well known that this model supports stable dissipative solitons. We demonstrate that the same model gives rise to several families of robust bound states of the solitons, which exists only in the presence of the TOD. There are both stationary and dynamical bound states, with oscillating separation between the bound solitons. Stationary states are multistable, corresponding to different values of the separation. With the increase of the TOD coefficient, the bound state with the smallest separation gives rise the oscillatory state through the Hopf bifurcation. Further growth of TOD leads to a bifurcation transforming the oscillatory limit cycle into a strange attractor, which represents a chaotically oscillating dynamical bound state. Families of multistable three- and four-soliton complexes are found too, the ones with the smallest separation between the solitons again ending by a transition to oscillatory states through the Hopf bifurcation.

  16. Study of moving object detecting and tracking algorithm for video surveillance system

    NASA Astrophysics Data System (ADS)

    Wang, Tao; Zhang, Rongfu

    2010-10-01

    This paper describes a specific process of moving target detecting and tracking in the video surveillance.Obtain high-quality background is the key to achieving differential target detecting in the video surveillance.The paper is based on a block segmentation method to build clear background,and using the method of background difference to detecing moving target,after a series of treatment we can be extracted the more comprehensive object from original image,then using the smallest bounding rectangle to locate the object.In the video surveillance system, the delay of camera and other reasons lead to tracking lag,the model of Kalman filter based on template matching was proposed,using deduced and estimated capacity of Kalman,the center of smallest bounding rectangle for predictive value,predicted the position in the next moment may appare,followed by template matching in the region as the center of this position,by calculate the cross-correlation similarity of current image and reference image,can determine the best matching center.As narrowed the scope of searching,thereby reduced the searching time,so there be achieve fast-tracking.

  17. Spatial solitons of desired intensity and width and their self-tapering/uptapering in cubic quintic nonlinear medium

    NASA Astrophysics Data System (ADS)

    Krishna Sarkar, Ram; Medhekar, S.

    2007-12-01

    In this paper, we have investigated the propagation behavior of a Gaussian beam in cubic quintic nonlinear medium with and without absorption or gain. A governing differential equation for the evolution of beam width with the distance of propagation has been derived using the standard parabolic equation approach. By solving the governing equation numerically for different sets of parameters, we have shown that spatial solitons of fixed width and desired intensity and of fixed intensity and desired width are possible. Such liberty does not exist in other saturable media. We have also investigated self-tapering and self-uptapering of spatial solitons in the presence of absorption or gain and showed that the rate of self-tapering/uptapering is not only controlled by the magnitude of absorption or gain but also by the values of cubic and quintic terms. It is revealed that by self-tapering, the smallest achievable soliton width decreases/increases by increasing the magnitude of the cubic/quintic term. It is also revealed that the smallest achievable soliton width by self-tapering, is smaller for a larger initial width.

  18. Modeling Large Scale Circuits Using Massively Parallel Descrete-Event Simulation

    DTIC Science & Technology

    2013-06-01

    exascale levels of performance, the smallest elements of a single processor can greatly affect the entire computer system (e.g. its power consumption...grow to exascale levels of performance, the smallest elements of a single processor can greatly affect the entire computer system (e.g. its power...Warp Speed 10.0. 2.0 INTRODUCTION As supercomputer systems approach exascale , the core count will exceed 1024 and number of transistors used in

  19. Abrasive Wear of Four Direct Restorative Materials by Standard and Whitening Dentifrices

    DTIC Science & Technology

    2013-06-01

    after an acidic challenge . Enamel loss was significantly greater when erosive and abrasive effects were combined. They concluded that acid-softened...surrounding soft tissues. Another benefit of restoration is the elimination of a challenging area for the patient and hygienist to clean. These areas...abrasion challenge ; the resin cement with the smallest sized filler particles had the smallest weight loss and maintained the smoothest surface of all the

  20. Smallest fullerene-like silicon cage stabilized by a V(2) unit.

    PubMed

    Xu, Hong-Guang; Kong, Xiang-Yu; Deng, Xiao-Jiao; Zhang, Zeng-Guang; Zheng, Wei-Jun

    2014-01-14

    We conducted a combined anion photoelectron spectroscopy and density functional theory study on V2Si20 cluster. Our results show that the V2Si20 cluster has an elongated dodecahedron cage structure with a V2 unit encapsulated inside the cage. It is the smallest fullerene-like silicon cage and can be used as building block to make cluster-assembled materials, such as pearl-chain style nanowires.

  1. Smallest fullerene-like silicon cage stabilized by a V2 unit

    NASA Astrophysics Data System (ADS)

    Xu, Hong-Guang; Kong, Xiang-Yu; Deng, Xiao-Jiao; Zhang, Zeng-Guang; Zheng, Wei-Jun

    2014-01-01

    We conducted a combined anion photoelectron spectroscopy and density functional theory study on V2Si20 cluster. Our results show that the V2Si20 cluster has an elongated dodecahedron cage structure with a V2 unit encapsulated inside the cage. It is the smallest fullerene-like silicon cage and can be used as building block to make cluster-assembled materials, such as pearl-chain style nanowires.

  2. The Path Resistance Method for Bounding the Smallest Nontrivial Eigenvalue of a Laplacian

    NASA Technical Reports Server (NTRS)

    Guattery, Stephen; Leighton, Tom; Miller, Gary L.

    1997-01-01

    We introduce the path resistance method for lower bounds on the smallest nontrivial eigenvalue of the Laplacian matrix of a graph. The method is based on viewing the graph in terms of electrical circuits; it uses clique embeddings to produce lower bounds on lambda(sub 2) and star embeddings to produce lower bounds on the smallest Rayleigh quotient when there is a zero Dirichlet boundary condition. The method assigns priorities to the paths in the embedding; we show that, for an unweighted tree T, using uniform priorities for a clique embedding produces a lower bound on lambda(sub 2) that is off by at most an 0(log diameter(T)) factor. We show that the best bounds this method can produce for clique embeddings are the same as for a related method that uses clique embeddings and edge lengths to produce bounds.

  3. An approach for maximizing the smallest eigenfrequency of structure vibration based on piecewise constant level set method

    NASA Astrophysics Data System (ADS)

    Zhang, Zhengfang; Chen, Weifeng

    2018-05-01

    Maximization of the smallest eigenfrequency of the linearized elasticity system with area constraint is investigated. The elasticity system is extended into a large background domain, but the void is vacuum and not filled with ersatz material. The piecewise constant level set (PCLS) method is applied to present two regions, the original material region and the void region. A quadratic PCLS function is proposed to represent the characteristic function. Consequently, the functional derivative of the smallest eigenfrequency with respect to PCLS function takes nonzero value in the original material region and zero in the void region. A penalty gradient algorithm is proposed, which initializes the whole background domain with the original material and decreases the area of original material region till the area constraint is satisfied. 2D and 3D numerical examples are presented, illustrating the validity of the proposed algorithm.

  4. Renormalization group naturalness of GUT Higgs potentials

    NASA Astrophysics Data System (ADS)

    Allanach, B. C.; Amelino-Camelia, G.; Philipsen, O.; Pisanti, O.; Rosa, L.

    1999-01-01

    We analyze the symmetry-breaking patterns of grand unified theories from the point of view of a recently proposed criterion of renormalization-group naturalness. We perform the analysis on simple non-SUSY SU(5) and SO(10) and SUSY SU(5) GUTs. We find that the naturalness criterion can favor spontaneous symmetry breaking in the direction of the smallest of the maximal little groups. Some differences between theories with and without supersymmetry are also emphasized.

  5. Unmanned Vanguard: Leveraging The Operational Effectiveness Of The Israeli Unmanned Aircraft System Program

    DTIC Science & Technology

    2012-04-01

    tactical electronic and optical reconnaissance (both high and low altitude); and 3) electronic combat (jamming and chaff dispensing).7 In contrast, the...sites or other radar sites. IAI designed the Harpy as a loitering UAS that would sit over the battlefield and search for electronic emissions from...tactical reconnaissance, and can be modified to carry different payloads for electronic warfare or attack missions. The Hermes 450 is the smallest

  6. Color and translucency in silorane-based resin composite compared to universal and nanofilled composites.

    PubMed

    Pérez, María M; Ghinea, Razvan; Ugarte-Alván, Laura I; Pulgar, Rosa; Paravina, Rade D

    2010-01-01

    The purpose of this study was to determine the optical properties, color and translucency, of the new silorane-based resin composite and to compare it to universal dimethacrylate-based composites. Six dimethacrylate-based resin composites and one silorane-based resin composite (all A2 shade) were studied. Color of non-polymerized and polymerized composites was measured against white and black backgrounds using a spectroradiometer. Changes in color (ΔE*(ab)), translucency (ΔTP) and color coordinates (ΔL*, Δa* and Δb*) were calculated for each resin composite. Results were evaluated using a one-way ANOVA, a Tukey's test and a t-test. The polymerization-dependent ΔE*(ab) ranged from 4.7 to 9.1, with the smallest difference for the silorane-based resin composite. The color changes of silorane-based composite were due to the changes of coordinates Δa* and Δb*. However, for the dimethacrylate-based composites, the color changes mainly originated by ΔL*and Δb*. The silorane composite exhibited the smallest TP values. Tukey's test confirmed significant statistical differences (p<0.05) between mean TP values of Filtek Silorane and each brand of dimethacrylate-based composites before and after polymerization. The new silorane-based restorative system showed different optical properties compared to clinically successful dimethacrylate composites. The silorane composite exhibited better polymerization-dependent chromatic stability, and a lower translucency compared to other tested products. Copyright © 2010 Elsevier Ltd. All rights reserved.

  7. Airway assessment by volumetric computed tomography in snorers and subjects with obstructive sleep apnea in a Far-East Asian population (Chinese).

    PubMed

    Chen, Ning-Hung; Li, Kasey K; Li, Shia-Yu; Wong, Chao-Reng; Chuang, Ming-Lung; Hwang, Chung-Chi; Wu, Yao-Kaung

    2002-04-01

    To evaluate the airway dimension of simple snorers and subjects with obstructive sleep apnea (OSA) in a Far-East Asian population (Chinese). Prospective study of 117 near-consecutive patients evaluated for snoring and possible OSA from January 1998 to December 1998 in a sleep laboratory. Overnight polysomnography (PSG) was performed on all patients and the sleep parameters, including respiratory disturbance index (RDI), snoring index, minimal oxygen saturation (min O2), percentage of slow wave sleep (SWS), and rapid eye movement (REM) were recorded. Three-dimensional computerized tomography (CT) during awake periods was performed. The anteroposterior (AP) and the lateral distance of the retropalatal (RP) region in the oropharynx, the smallest area of RP, and retroglossal (RG) regions, and the total volume of the oropharynx were measured. Ninety-eight patients were diagnosed with OSA (mean RDI, 41.48 +/- 26.45 events per hour; min O2, 72.82 +/- 12.86%), whereas 19 were simple snorers. The AP and the lateral distance of the RP region, as well as the smallest area of the RP region, are significantly smaller in subjects with OSA. However, no differences in the RG region and the total volume of the oropharynx were found between the two groups. Linear regression analysis demonstrated that the lateral dimension and the smallest RP area in overweight subjects inversely correlated with the RDI, but only the AP dimension of the RP area was found to have an inverse correlation with the RDI in the underweight subjects. In Far-East Asians (Chinese), the RP airway was found to be the primary site of narrowing in subjects with OSA, and the narrowest RP area was inversely correlated with RDI. Furthermore, weight may influence the pattern of RP narrowing by contributing to lateral collapse.

  8. Software thresholds alter the bias of actigraphy for monitoring sleep in team-sport athletes.

    PubMed

    Fuller, Kate L; Juliff, Laura; Gore, Christopher J; Peiffer, Jeremiah J; Halson, Shona L

    2017-08-01

    Actical ® actigraphy is commonly used to monitor athlete sleep. The proprietary software, called Actiware ® , processes data with three different sleep-wake thresholds (Low, Medium or High), but there is no standardisation regarding their use. The purpose of this study was to examine validity and bias of the sleep-wake thresholds for processing Actical ® sleep data in team sport athletes. Validation study comparing actigraph against accepted gold standard polysomnography (PSG). Sixty seven nights of sleep were recorded simultaneously with polysomnography and Actical ® devices. Individual night data was compared across five sleep measures for each sleep-wake threshold using Actiware ® software. Accuracy of each sleep-wake threshold compared with PSG was evaluated from mean bias with 95% confidence limits, Pearson moment-product correlation and associated standard error of estimate. The Medium threshold generated the smallest mean bias compared with polysomnography for total sleep time (8.5min), sleep efficiency (1.8%) and wake after sleep onset (-4.1min); whereas the Low threshold had the smallest bias (7.5min) for wake bouts. Bias in sleep onset latency was the same across thresholds (-9.5min). The standard error of the estimate was similar across all thresholds; total sleep time ∼25min, sleep efficiency ∼4.5%, wake after sleep onset ∼21min, and wake bouts ∼8 counts. Sleep parameters measured by the Actical ® device are greatly influenced by the sleep-wake threshold applied. In the present study the Medium threshold produced the smallest bias for most parameters compared with PSG. Given the magnitude of measurement variability, confidence limits should be employed when interpreting changes in sleep parameters. Copyright © 2017 Sports Medicine Australia. All rights reserved.

  9. Sources of Variability in Performance Times at the World Orienteering Championships.

    PubMed

    Hébert-Losier, Kim; Platt, Simon; Hopkins, William G

    2015-07-01

    An improvement equal to 0.3 of the typical variation in an elite athlete's race-to-race performance estimates the smallest worthwhile enhancement, which has not yet been determined for orienteers. Moreover, much of the research in high-performance orienteering has focused on physical and cognitive aspects, although course characteristics might influence race performance. Analysis of race data provides insights into environmental effects and other aspects of competitive performance. Our aim was to examine such factors in relation to World Orienteering Championships performances. We used mixed linear modelling to analyze finishing times from the three qualification rounds and final round of the sprint, middle-distance, and long-distance disciplines of World Orienteering Championships from 2006 to 2013. Models accounted for race length, distance climbed, number of controls, home advantage, venue identity, round (qualification final), athlete identity, and athlete age. Within-athlete variability (coefficient of variation, mean ± SD) was lower in the final (4.9% ± 1.4%) than in the qualification (7.3% ± 2.4%) rounds and provided estimates of smallest worthwhile enhancements of 1.0%-3.5%. The home advantage was clear in most disciplines, with distance climbed particularly impacting sprint performances. Small to very large between-venue differences were apparent. Performance predictability expressed as intraclass correlation coefficients was extremely high within years and was high to very high between years. Age of peak performance ranged from 27 to 31 yr. Our results suggest that elite orienteers should focus on training and strategies that enhance performance by at least 1.0%-3.5% for smallest worthwhile enhancement. Moreover, as greater familiarity with the terrain likely mediated the home advantage, foreign athletes would benefit from training in nations hosting the World Orienteering Championships for familiarization.

  10. Does Aggressive Phototherapy Increase Mortality while Decreasing Profound Impairment among the Smallest and Sickest Newborns?

    PubMed Central

    Tyson, Jon E; Pedroza, Claudia; Langer, John; Green, Charles; Morris, Brenda; Stevenson, David; Van Meurs, Krisa P.; Oh, William; Phelps, Dale; O’Shea, Michael; McDavid, Georgia E.; Grisby, Cathy; Higgins, Rose

    2013-01-01

    Objective Aggressive phototherapy (AgPT) is widely used and assumed to be safe and effective for even the most immature infants. We assessed whether the benefits and hazards for the smallest and sickest infants differed from those for other extremely low birth weight (ELBW; (≤1000 g) infants in our Neonatal Research Network trial, the only large trial of AgPT. Study Design ELBW infants (n=1974) were randomized to AgPT or conservative phototherapy at age 12–36 hours. The effect of AgPT on outcomes (death; impairment; profound impairment; death or impairment [primary outcome], and death or profound impairment) at 18–22 months corrected age was related to BW stratum (501–750 g; 751–1000 g) and baseline severity of illness using multilevel regression equations. The probability of benefit and of harm was directly assessed with Bayesian analyses. Results Baseline illness severity was well characterized using mechanical ventilation and FiO2 at 24 hours age. Among mechanically ventilated infants ≤750 g BW (n =684), a reduction in impairment and in profound impairment was offset by higher mortality (p for interaction <0.05) with no significant effect on composite outcomes. Conservative Bayesian analyses of this subgroup identified a 99% (posterior) probability that AgPT increased mortality, a 97% probability that AgPT reduced impairment, and a 99% probability that AgPT reduced profound impairment. Conclusions Findings from the only large trial of AgPT suggest that AgPT may increase mortality while reducing impairment and profound impairment among the smallest and sickest infants. New approaches to reduce their serum bilirubin need development and rigorous testing. PMID:22652561

  11. European ring exercise on water toxicity using different bioluminescence inhibition tests based on Vibrio fischeri, in support to the implementation of the water framework directive.

    PubMed

    Farré, Marinella; Martínez, Elena; Hernando, M-D; Fernández-Alba, Amadeo; Fritz, Johann; Unruh, Eckehardt; Mihail, Otilia; Sakkas, Vasilis; Morbey, Ana; Albanis, Triantafyllos; Brito, Fatima; Hansen, Peter D; Barceló, Damià

    2006-04-15

    An inter-laboratory comparison exercise was conducted under the European Union funded project entitled: Screening Methods for Water Data Information in Support of the Implementation of the Water Framework Directive (SWIFT-WFD) and coordinated by the Consejo Superior de Investigaciones Científicas (CSIC), in order to evaluate the reproducibility of different toxicity tests based on the bioluminescence inhibition of Vibrio fischeri, for the rapid water toxicity assessment. For the first time, this type of exercise has been organized in Europe, and using different tests based on the same principle. In this exercise, 10 laboratories from 8 countries (Austria, Cyprus, Germany, Greece, Italy, Portugal, Romania, and Spain) took place, and a total number of 360 samples were distributed. During the exercise, six series of six samples were analyzed along 5 months. Every batch of samples was composed by three real samples and three standard solutions. The real samples were: a raw influent and the effluent of a wastewater treatment plant (WWTP), and a sample from a first settlement of the WWTP spiked with a mixture of toxicant standards. A final number of 330 (91.7%) samples was analyzed, 3300 values in duplicate were collected, and the results for each sample were expressed as the 50% effective concentration (EC(50)) values calculated through five points of dilution inhibition curves, after 5 and 15min of incubation times. A statistical study was initiated using 660 results. The mean values, standard deviations (sigma), variances (sigma(2)), and upper and lower warning limits (UWL and LWL) were obtained, using the EC(50) values calculated with the result from the participating laboratories. The main objectives of this toxicity ring study were to evaluate the repeatability (r) and reproducibility (R) when different laboratories conduct the test, the influence of complex matrix samples, the variability between different tests based on the same principle, and to determine the rate at which participating laboratories successfully completed tests initiated. In this exercise, the 3.93% toxicity values were outliers according with the Z-score values and the Dixon test. The samples with the greater number of outliers were those with the smallest variability coefficient, corresponding to the greater and the smaller toxicity level. No relation was found through the cluster analysis, between the final results and the different commercial devices involved. Testing by multiple commercial devices did not appear to reduce the precision of the results, and the variability coefficient for the exercise was nearby to the average value for past editions carried out at national level, where the different participants used the same commercial device. Stability of samples was also followed during the exercise. While statistical significance differences were not found for the greater part of samples, for the sample from the WWTP influent, a significant decrease of the toxicity value was found along this study. Nevertheless, this was a type of sample with a high toxicity level during all the exercise. On the other hand, in order to obtain the chemical characterization of real samples, those were analyzed by chromatographic techniques, using different sequential solid phase extraction (SSPE) procedures, followed by liquid chromatography coupled with mass spectrometry (LC-MS), and gas chromatography-mass spectrometry (GC-MS). Good agreement was found between the chemical analysis results and the toxicity level of the samples.

  12. Statistics of Lyapunov exponents of quasi-one-dimensional disordered systems

    NASA Astrophysics Data System (ADS)

    Zhang, Yan-Yang; Xiong, Shi-Jie

    2005-10-01

    Statistical properties of Lyapunov exponents (LE) are numerically calculated in a quasi-one-dimensional (1D) Anderson model, which is in a 2D or 3D lattice with a finite cross section. The single-parameter scaling (SPS) variable τ relating the Lyapunov exponents γ and their variances σ by τ≡σ2L/⟨γ⟩ is calculated for different lateral coupling t and disorder strength W . In a wide range of t , τ is approximately independent of W , but it has different values for LEs in different channels. For small t , the distribution of the smallest LE is non-Gaussian and τ strongly depends on W , remarkably different from the 1D SPS hypothesis.

  13. Corneal Power Distribution and Functional Optical Zone Following Small Incision Lenticule Extraction for Myopia.

    PubMed

    Qian, Yishan; Huang, Jia; Zhou, Xingtao; Hanna, Rewais Benjamin

    2015-08-01

    To evaluate corneal power distribution using the ray tracing method (corneal power) in eyes undergoing small incision lenticule extraction (SMILE) surgery and compare the functional optical zone with two lenticular sizes. This retrospective study evaluated 128 patients who underwent SMILE for the correction of myopia and astigmatism with a lenticular diameter of 6.5 mm (the 6.5-mm group) and 6.2 mm (the 6.2-mm group). The data include refraction, correction, and corneal power obtained via a Scheimpflug camera from the pupil center to 8 mm. The surgically induced changes in corneal power (Δcorneal power) were compared to correction and Δrefraction. The functional optical zone was defined as the largest ring diameter when the difference between the ring power and the pupil center power was 1.50 diopters or less. The functional optical zone was compared between two lenticular diameter groups. Corneal power distribution was measured by the ray tracing method. In the 6.5-mm group (n=100), Δcorneal power at 5 mm showed the smallest difference from Δrefraction and Δcorneal power at 0 mm exhibited the smallest difference from correction. In the 6.2-mm group (n=28), Δcorneal power at 2 mm displayed the lowest dissimilarity from Δrefraction and Δcorneal power at 4 mm demonstrated the lowest dissimilarity from correction. There was no significant difference between the mean postoperative functional optical zones in either group when their spherical equivalents were matched. Total corneal refactive power can be used in the evaluation of surgically induced changes following SMILE. A lenticular diameter of 6.2 mm should be recommended for patients with high myopia because there is no functional difference in the optical zone. Copyright 2015, SLACK Incorporated.

  14. Effects of Pore Size on the Osteoconductivity and Mechanical Properties of Calcium Phosphate Cement in a Rabbit Model.

    PubMed

    Zhao, Yi-Nan; Fan, Jun-Jun; Li, Zhi-Quan; Liu, Yan-Wu; Wu, Yao-Ping; Liu, Jian

    2017-02-01

    Calcium phosphate cement (CPC) porous scaffold is widely used as a suitable bone substitute to repair bone defect, but the optimal pore size is unclear yet. The current study aimed to evaluate the effect of different pore sizes on the processing of bone formation in repairing segmental bone defect of rabbits using CPC porous scaffolds. Three kinds of CPC porous scaffolds with 5 mm diameters and 12 mm length were prepared with the same porosity but different pore sizes (Group A: 200-300 µm, Group B: 300-450 µm, Group C: 450-600 µm, respectively). Twelve millimeter segmental bone defects were created in the middle of the radius bone and filled with different kinds of CPC cylindrical scaffolds. After 4, 12, and 24 weeks, alkaline phosphatase (ALP), histological assessment, and mechanical properties evaluation were performed in all three groups. After 4 weeks, ALP activity increased in all groups but was highest in Group A with smallest pore size. The new bone formation within the scaffolds was not obvious in all groups. After 12 weeks, the new bone formation within the scaffolds was obvious in each group and highest in Group A. At 24 weeks, no significant difference in new bone formation was observed among different groups. Besides the osteoconductive effect, Group A with smallest pore size also had the best mechanical properties in vivo at 12 weeks. We demonstrate that pore size has a significant effect on the osteoconductivity and mechanical properties of calcium phosphate cement porous scaffold in vivo. Small pore size favors the bone formation in the early stage and may be more suitable for repairing segmental bone defect in vivo. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  15. Factors affecting variation in CH4 emission from paddy soils grown with different rice cultivars: A pot experiment

    NASA Astrophysics Data System (ADS)

    Watanabe, Akira; Kimura, Makoto

    1998-08-01

    The growth of rice plants greatly influences CH4 emission from paddy fields through the supply of organic materials such as root exudates and sloughed tissues, the release of oxygen to the root environment, and the transfer of CH4 from the rhizosphere into the atmosphere through the aerenchyma. In the present pot experiments, the effects of the release of water-soluble organic substances from roots, the air space in roots, and the CH4-oxidizing capacity of roots on intervarietal differences in CH4 emission were examined using three Japonica type cultivars (Norin 25, Nipponbare, and Aoinokaze), which differ in morphological properties. The CH4 emission rates varied among the cultivars from mid-July (tillering stage) to the beginning of September (heading stage).Total CH4 emission throughout the rice growth period was largest for Norin 25, followed by Nipponbare, and Aoinokaze. In August, the rate of release of water-soluble organic substances from roots was largest for Norin 25. The air space in roots was also largest in Norin 25 and least in Aoinokaze. The stable carbon isotopic ratios (δ13C) of CH4 in roots were 3-10‰ higher than those in soil in August. The difference in δ13C values of CH4 between roots and soil was largest for Aoinokaze and smallest for Norin 25. In September, the difference in δ13C values of CH4 between roots and soil became small (2-3‰). These findings suggest that the proportion of CH4 oxidation in the rhizosphere was largest in the cultivar which emitted the smallest amount of CH4 and that the proportion became smaller with continued plant growth.

  16. Data Delivery Latency Improvements And First Steps Towards The Distributed Computing Of The Caltech/USGS Southern California Seismic Network Earthquake Early Warning System

    NASA Astrophysics Data System (ADS)

    Stubailo, I.; Watkins, M.; Devora, A.; Bhadha, R. J.; Hauksson, E.; Thomas, V. I.

    2016-12-01

    The USGS/Caltech Southern California Seismic Network (SCSN) is a modern digital ground motion seismic network. It develops and maintains Earthquake Early Warning (EEW) data collection and delivery systems in southern California as well as real-time EEW algorithms. Recently, Behr et al., SRL, 2016 analyzed data from several regional seismic networks deployed around the globe. They showed that the SCSN was the network with the smallest data communication delays or latency. Since then, we have reduced further the telemetry delays for many of the 330 current sites. The latency has been reduced on average from 2-6 sec to 0.4 seconds by tuning the datalogger parameters and/or deploying software upgrades. Recognizing the latency data as one of the crucial parameters in EEW, we have started archiving the per-packet latencies in mseed format for all the participating sites in a similar way it is traditionally done for the seismic waveform data. The archived latency values enable us to understand and document long-term changes in performance of the telemetry links. We can also retroactively investigate how latent the waveform data were during a specific event or during a specific time period. In addition the near-real time latency values are useful for monitoring and displaying the real-time station latency, in particular to compare different telemetry technologies. A future step to reduce the latency is to deploy the algorithms on the dataloggers at the seismic stations and transmit either the final solutions or intermediate parameters to a central processing center. To implement this approach, we are developing a stand-alone version of the OnSite algorithm to run on the dataloggers in the field. This will increase the resiliency of the SCSN to potential telemetry restrictions in the immediate aftermath of a large earthquake, either by allowing local alarming by the single station, or permitting transmission of lightweight parametric information rather than continuous waveform data to the central processing facility. State-of-the-art development of Internet of Things (IoT) tools and platforms, which can be used to distribute and maintain software on a large number of remote devices are making this approach to earthquake early warning more feasible.

  17. Smallest fullerene-like silicon cage stabilized by a V{sub 2} unit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, Hong-Guang, E-mail: xuhong@iccas.ac.cn, E-mail: zhengwj@iccas.ac.cn; Kong, Xiang-Yu; Deng, Xiao-Jiao

    We conducted a combined anion photoelectron spectroscopy and density functional theory study on V{sub 2}Si{sub 20} cluster. Our results show that the V{sub 2}Si{sub 20} cluster has an elongated dodecahedron cage structure with a V{sub 2} unit encapsulated inside the cage. It is the smallest fullerene-like silicon cage and can be used as building block to make cluster-assembled materials, such as pearl-chain style nanowires.

  18. City of Troitsk and Sooty Snow, Chelyabinsk, CIS

    NASA Technical Reports Server (NTRS)

    1992-01-01

    This view shows the industrial pollution around the Siberian city of Troitsk (54.0N, 61.0E). Troitsk is the smallest of a group of three heavy industrial cities east of the Urals, the others being Magnitogorsk and Chelyabinsk. All have been cited as being some of the worst industrial polluted cities in the CIS. Despite being the smallest of the three, Troitsk has the largest area of soot blackened snow. Respiratory diseases among the citizens are chronic.

  19. A quantitative study of ramped radio frequency, magnetization transfer, and slab thickness in three-dimensional time-of-flight magnetic resonance angiography in a patient population.

    PubMed

    Goodrich, K C; Blatter, D D; Parker, D L; Du, Y P; Meyer, K J; Bernstein, M A

    1996-06-01

    The authors compare the effectiveness of various magnetic resonance (MR) angiography acquisition strategies in enhancing the visibility of small intracranial vessels. Blood vessel contrast-to-noise ratio (CNR) in time-of-flight MR angiography was studied as a function of vessel size and several selectable imaging parameters. Contrast-to-noise measurements were made on 257 vessel segments ranging in size from 0.3 mm to 4.2 mm in patients who recently had undergone intraarterial cerebral angiography. Imaging parameters studied included magnetization transfer, spatially variable radio frequency (RF) pulse profile (ramped RF), and imaging slab thickness. The combination of thin slabs (16 slices/slab), ramped RF, and magnetization transfer resulted in the highest CNR for all but the smallest vessel sizes. The smallest vessels (< 0.5 mm) had the highest CNR, using the thick slab (64 slices/slab) with ramped RF and magnetization transfer. Magnetization transfer always improved vessel CNR, but the improvement diminished as the slab thickness was reduced. The CNR increased with a decrease in slab thickness for all but the smallest vessel sizes. Overall, the results provide a quantitative demonstration that inflow enhancement of blood is reduced for small vessels. Thus, whereas magnetization transfer is important at all vessel sizes, it becomes the primary factor in improving the visibility of the smallest vessels.

  20. Sizes of the Smallest Particles at the Outer B Ring Edge, Huygens Ringlet, and Strange Ringlet

    NASA Astrophysics Data System (ADS)

    Eckert, Stephanie; Colwell, Josh E.; Becker, Tracy M.; Esposito, Larry W.

    2016-10-01

    The Cassini Ultraviolet Imaging Spectrograph (UVIS)'s High Speed Photometer (HSP) has observed stellar occultations of Saturn's rings that reveal ring structure at high resolution. We observe diffraction spikes at the sharp edges of some rings and ringlets where the observed signal exceeds the unocculted star signal, indicating that small particles are diffracting light into the detector. Becker et al. (2015 Icarus doi:10.1016/j.icarus.2015.11.001) analyzed data at the A ring edge and edges of the Encke gap. The smallest particle sizes were a few mm. We use the same technique to analyze the diffraction signal at the outer edge of the B ring and the edges of the so-called Strange ringlet near the outer edge of the Huygens Gap. While we see diffraction from sub-cm particles in the Strange Ringlet, detections from the wider Huygens Ringlet which resides in between the Strange Ringlet and the outer edge of the B ring are weaker and narrower, indicating a cutoff of the size distribution above 1 cm. At the outer edge of the B ring we find strong diffraction signals in 7 of 19 occultations for which the signal and geometry make the detection possible. The typical value of the smallest particle size (amin) is 4 mm and the derived slope of the power-law size distribution (q) is 2.9. The average amin is similar to the 4.5 mm average observed at the A ring outer edge while the q value is lower than the A ring outer edge value of 3.2. In the Strange Ringlet we find strong diffraction signals in 2 of 19 possible occultations for the outer edge and 1 of 17 possible occultations for the inner edge. The smallest particle size is ~5 mm and the derived slope of the power-law size distribution is 3.3. These values are similar to the average values at the A ring outer edge. The absence of a broad diffraction signal at the Huygens Ringlet suggests a different size distribution for that ring than for the Strange Ringlet and the outer several km of the B ring or perhaps less vigorous collisions so that fewer small particles are liberated from the regolith of larger particles.

  1. [A study of sympathetic skin response to the damage of autonomic nerves function in patients with chronic N-hexane poisoning].

    PubMed

    Situ, Jie; Wu, Jian; Wang, Jing-lin; Zhu, De-xiang; Zhang, Jian-jie; Liu, Wei-wei; Qin, Zhuo-hui

    2012-05-01

    To study the sympathetic skin response (SSR) to the effects of N-hexane on autonomic nerves function in patients with chronic N-hexane poisoning. The subjects in present study included 30 controls and 37 cases with chronic N-hexane poisoning. Also 37 patients were divided into 3 subgroups (mild, moderate and severe poisoning) according to diagnostic criteria of occupational diseases. All subjects were examined by SSR test and nerve conduction velocity (NCV) test. All patients were reexamined by SSR and NCV every 1 ∼ 2 months. The differences in SSR parameters (latency, amplitude) among groups were observed. In the severe poisoning subgroup, the changes of SSR and NCV parameters (conduction velocity, amplitude) in different poisoning stages were observed. There were significant differences in SSR latency of upper extremity among groups and the significant differences in SSR amplitude of upper and lower extremity among groups (P < 0.05). No significant differences in SSR parameters were found between the adjacent groups (P > 0.05). There were significant differences in SSR latency of upper extremity during different periods and the significant differences in SSR amplitude of upper and lower extremity during different periods among all groups (P < 0.05). The change of SSR parameters consistent with that in NCV. The longest SSR latency of upper extremity and the smallest SSR amplitudes of upper and lower extremity appears 1 - 2 months earlier than that of the smallest action potential amplitude. The damage of autonomic nerves induced by N-hexane increased with poisoning progresses. The damage of autonomic nerves corresponded with the damage of myelin sheath of large myelinated nerves, but which appeared 1 - 2 months earlier than the damage of axon of large myelinated nerves. SSR test may serve as a method to detect the damage of autonomic nerves function in patients with chronic N-hexane poisoning.

  2. Psycho-Motor and Error Enabled Simulations: Modeling Vulnerable Skills in the Pre-Mastery Phase

    DTIC Science & Technology

    2016-04-01

    participants. Multiple abstracts and posters were created for surgical conferences attended. These works concentrated on data from pre and post ...analyzed to give every participant a perspective of the smallest difference in stiffness they could differentiate. Based on the results the tests were...camera was affixed to a post mounted to this station’s table to capture a close-up view of the participant’s placement of needles on the simulation

  3. Ultimate Atomic Bling: Nanotechnology of Diamonds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dahl, Jeremy

    2010-05-25

    Diamonds exist in all sizes, from the Hope Diamond to minuscule crystals only a few atoms across. The smallest of these diamonds are created naturally by the same processes that make petroleum. Recently, researchers discovered that these 'diamondoids' are formed in many different structural shapes, and that these shapes can be used like LEGO blocks for nanotechnology. This talk will discuss the discovery of these nano-size diamonds and highlight current SLAC/Stanford research into their applications in electronics and medicine.

  4. Does variation in cranial morphology of Myotis occultus (Chiroptera: Vespertilionidae) reflect a greater reliance on certain prey types?

    USGS Publications Warehouse

    Valdez, Ernest W.; Bogan, Michael A.

    2009-01-01

    Few studies have investigated the relationship between morphological variation and local feeding habits of bats in the United States. We used discriminant function analysis (DFA) to compare cranial morphology of Myotis occultus from southern Colorado, and central, and southern New Mexico. We analyzed guano collected from maternity colonies in southern Colorado and central New Mexico to compare food habits. Bats from southern Colorado had the smallest values on the first canonical variate (CV1) that also reflected the smallest measurements of key cranial and dental variables, including height of coronoid process, width of molar, and dentary thickness. Bats from central and southern New Mexico had intermediate and large CV1 values, respectively. Overall, CV1 discriminated individuals occurring in southern Colorado and central New Mexico from those in southern New Mexico. CV2 served best at discriminating bats of southern Colorado from those of central New Mexico. Comparison of food habits revealed that individuals from southern Colorado ate more soft-bodied prey items (e.g., flies) whereas bats from central New Mexico ate more hard-bodied prey items (e.g., beetles). As shown in earlier studies that investigated relationships between morphology and diet of insectivorous bats, we found differences in skull morphology of M. occultusthat were correlated with differences in food habits.

  5. Genome rearrangement shapes Prochlorococcus ecological adaptation.

    PubMed

    Yan, Wei; Wei, Shuzhen; Wang, Qiong; Xiao, Xilin; Zeng, Qinglu; Jiao, Nianzhi; Zhang, Rui

    2018-06-18

    Prochlorococcus is the most abundant and smallest known free-living photosynthetic microorganism and is a key player in marine ecosystems and biogeochemical cycles. Prochlorococcus can be broadly divided into high-light-adapted (HL) and low-light-adapted (LL) clades. In this study, we isolated two low-light-adapted I (LLI) strains from the western Pacific Ocean and obtained their genomic data. We reconstructed Prochlorococcus evolution based on genome rearrangement. Our results showed that genome rearrangement might have played an important role in Prochlorococcus evolution. We also found that the Prochlorococcus clades with streamlined genomes maintained relatively high synteny throughout most of their genomes, and several regions served as rearrangement hotspots. Backbone analysis showed that different clades shared a conserved backbone but also had clade-specific regions, and the genes in these regions were associated with ecological adaptations. Importance Prochlorococcus , the most abundant and smallest known free-living photosynthetic microorganism, play a key role in marine ecosystems and biogeochemical cycles. The Prochlorococcus genome evolution is a fundamental question related to how Prochlorococcus clades adapted to different ecological niches. Recent studies revealed that the gene gain and loss is crucial to the clade differentiation. The significance of our research is that we interpreted the Prochlorococcus genome evolution from the perspective of genome structure, and associated the genome rearrangement with the Prochlorococcus clade differentiation and subsequent ecological adaptation. Copyright © 2018 Yan et al.

  6. Comparison of Conventional Methods and Laser-Assisted Rapid Prototyping for Manufacturing Fixed Dental Prostheses: An In Vitro Study

    PubMed Central

    Pompa, Giorgio; Di Carlo, Stefano; De Angelis, Francesca; Cristalli, Maria Paola; Annibali, Susanna

    2015-01-01

    This study assessed whether there are differences in marginal fit between laser-fusion and conventional techniques to produce fixed dental prostheses (FDPs). A master steel die with 2 abutments was produced to receive a posterior 4-unit FDPs and single copings. These experimental models were divided into three groups (n = 20/group) manufactured: group 1, Ni-Cr alloy, with a lost-wax casting technique; group 2, Co-Cr alloy, with selective laser melting (SLM); and group 3, yttria-tetragonal zirconia polycrystal (Y-TZP), with a milling system. All specimens were cut along the longitudinal axis and their adaptation was measured at the marginal and shoulder areas on the right and left sides of each abutment. Measurements were made using a stereomicroscope (×60 magnification) and a scanning electron microscope (×800 magnification). The data were analyzed using one-way analysis of variance and the Bonferroni post hoc test, with a significance cutoff of 5%. Significant differences (P < 0.05) were observed between group 3 and the other groups. The marginal opening was smallest with Co-Cr alloy substructures, while the shoulder opening was smallest with Ni-Cr alloy substructures. Within the limitations of this study, the marginal fit of an FDP is better with rapid prototyping (RP) via SLM than conventional manufacturing systems. PMID:26576419

  7. Antibacterial activity study of Attacus atlas cocoon against Staphylococcus aureus and Escherichia coli with diffusion and dilution method

    NASA Astrophysics Data System (ADS)

    Aminah; Nugraheni, E. R.; Yugatama, A.

    2018-03-01

    The aim of this study was to evaluate the antibacterial activity from Attacus atlas cocoon extract against Gram-negative bacteria (Escherichia coli) and Gram-positive bacteria (Staphylococcus aureus) with 3 diffferent solvents polar, semi-polar and non polar which was ethanol, ethyl acetate and chloroform, also to determine the Minimum Inhibitory Concentration (MIC) and Minimum Bactericidal Concentration (MBC) of the extract. Cocoon was extracted with maceration method using 3 solvents with ratio of sample and solvent 1:10. Antibacterial activity of the Extracts obtained was evaluated with Agar disk diffusion method. The best result was then continued to determine the MIC and MBC of the extract using broth macro-dilution method. The results show that each of the extracts have antibacterial activity with broad spectrum against two different type of bacteria at concentration of 1 g/mL with different clear zone between these extracts. Clear zone from the biggest to the smallest against Escherichia coli was ethyl acetate (10.5 mm), chloroform (9 mm) and ethanol (8 mm). While against Staphylococcus aureus, was obtained by chloroform (12.5 mm), ethyl acetate (10.5 mm) and ethanol (7 mm). The MIC value of extracts can not be determine. The smallest MBC value against both bacteria was obtained by ethyl acetate with concentration of 3.125% b/v as a bactericidal.

  8. Unilateral lower limb strength assessed using the Nintendo Wii Balance Board: a simple and reliable method.

    PubMed

    Blomkvist, A W; Andersen, S; de Bruin, E; Jorgensen, M G

    2017-10-01

    Lower limb weakness is an important risk factor for fall accidents and a predictor for all-cause mortality among older adults. Unilateral whole-lower limb strength may be a better measure of fall risk than the bilateral measure. In addition, a number of clinical conditions affect only one leg, and thus this type of assessment is relevant in clinical settings. To explore the intra-rater reproducibility of the Nintendo Wii Balance Board (WBB) to measure unilateral whole-lower limb strength and to compare the method with stationary isometric muscle apparatus (SID). Intra-rater test-retest design with 1 week between sessions. Thirty community-dwelling older adults (69 ± 4.2 years) were enrolled and examined for maximum lower limb strength in their dominant and non-dominant leg. Intraclass correlation coefficient (ICC) was calculated to describe relative reproducibility, while standard error of measurement (SEM), limits of agreement (LOA) and smallest real difference (SRD) were calculated to describe absolute reproducibility between test sessions. Concurrent validity with the SID was explored using the Pearson product-moment correlation coefficient (PCC). No systematic difference was observed between test sessions. ICC was 0.919-0.950 and SEM, LOA and SRD was 2.9-4.1 kg, 24.1-28.3 kg and 7.6-11.3 kg, respectively. Further, the PCC was 0.755 and 0.730 for the dominant limb and the non-dominant limb, respectively. A high relative and an acceptable absolute reproducibility was seen when using the Nintendo Wii Balance Board for testing unilateral lower limb strength in community-dwelling older adults. The WBB correlated strongly with the SID.

  9. The order of the quantum chromodynamics transition predicted by the standard model of particle physics.

    PubMed

    Aoki, Y; Endrodi, G; Fodor, Z; Katz, S D; Szabó, K K

    2006-10-12

    Quantum chromodynamics (QCD) is the theory of the strong interaction, explaining (for example) the binding of three almost massless quarks into a much heavier proton or neutron--and thus most of the mass of the visible Universe. The standard model of particle physics predicts a QCD-related transition that is relevant for the evolution of the early Universe. At low temperatures, the dominant degrees of freedom are colourless bound states of hadrons (such as protons and pions). However, QCD is asymptotically free, meaning that at high energies or temperatures the interaction gets weaker and weaker, causing hadrons to break up. This behaviour underlies the predicted cosmological transition between the low-temperature hadronic phase and a high-temperature quark-gluon plasma phase (for simplicity, we use the word 'phase' to characterize regions with different dominant degrees of freedom). Despite enormous theoretical effort, the nature of this finite-temperature QCD transition (that is, first-order, second-order or analytic crossover) remains ambiguous. Here we determine the nature of the QCD transition using computationally demanding lattice calculations for physical quark masses. Susceptibilities are extrapolated to vanishing lattice spacing for three physical volumes, the smallest and largest of which differ by a factor of five. This ensures that a true transition should result in a dramatic increase of the susceptibilities. No such behaviour is observed: our finite-size scaling analysis shows that the finite-temperature QCD transition in the hot early Universe was not a real phase transition, but an analytic crossover (involving a rapid change, as opposed to a jump, as the temperature varied). As such, it will be difficult to find experimental evidence of this transition from astronomical observations.

  10. Severity and functional disability of patients with occupational contact dermatitis: validation of the German version of the Occupational Contact Dermatitis Disease Severity Index.

    PubMed

    Ofenloch, Robert F; Diepgen, Thomas L; Popielnicki, Ana; Weisshaar, Elke; Molin, Sonja; Bauer, Andrea; Mahler, Vera; Elsner, Peter; Schmitt, Jochen; Apfelbacher, Christian

    2015-02-01

    The Occupational Contact Dermatitis Disease Severity Index (ODDI) was designed in Australia to measure severity and functional disability in patients with occupational contact dermatitis (OCD) of the hands. The ODDI was translated into the German language with a linguistic validation process. The psychometric properties of the German version of the ODDI are still unclear. To report the linguistic validation procedure and to perform a psychometric validation by investigating the validity and reliability of the German ODDI version in a sample of patients with OCD. Data were drawn from the baseline assessment (T0) and first follow-up (T1) of the German chronic hand eczema (CHE) registry (CARPE). Spearman correlations of the ODDI with reference measures were computed to assess validity. Cronbach's alpha was calculated as a measure of internal consistency, and the intraclass correlation coefficient (ICC) was calculated to assess retest reliability. The smallest real difference (SRD) and minimal clinically important difference (MCID) were calculated to assess sensitivity to change. Physician Global Assessment (PGA) was used as an anchor for the MCID. Four hundred and twenty-two patients (54.5% female, mean age 45.1 years) were included for analysis. Cronbach's alpha was found to be 0.73. The ICC was 0.79. Correlations between the ODDI total and the Dermatology Life Quality Index (rho = 0.36), and between PGA (rho = 0.48) and patient-assessed disease severity (rho = 0.40), were of moderate strength. The MCID (1.29) was found to be smaller than the SRD (1.87). The German ODDI version is reliable and valid for the measurement of functional impairment and disease severity in patients suffering from OCD. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Validity of the microsoft kinect system in assessment of compensatory stepping behavior during standing and treadmill walking.

    PubMed

    Shani, Guy; Shapiro, Amir; Oded, Goldstein; Dima, Kagan; Melzer, Itshak

    2017-01-01

    Rapid compensatory stepping plays an important role in preventing falls when balance is lost; however, these responses cannot be accurately quantified in the clinic. The Microsoft Kinect™ system provides real-time anatomical landmark position data in three dimensions (3D), which may bridge this gap. Compensatory stepping reactions were evoked in 8 young adults by a sudden platform horizontal motion on which the subject stood or walked on a treadmill. The movements were recorded with both a 3D-APAS motion capture and Microsoft Kinect™ systems. The outcome measures consisted of compensatory step times (milliseconds) and length (centimeters). The average values of two standing and walking trials for Microsoft Kinect™ and the 3D-APAS systems were compared using t -test, Pearson's correlation, Altman-bland plots, and the average difference of root mean square error (RMSE) of joint position. The Microsoft Kinect™ had high correlations for the compensatory step times ( r  = 0.75-0.78, p  = 0.04) during standing and moderate correlations for walking ( r  = 0.53-0.63, p  = 0.05). The step length, however had a very high correlations for both standing and walking ( r  > 0.97, p  = 0.01). The RMSE showed acceptable differences during the perturbation trials with smallest relative error in anterior-posterior direction (2-3%) and the highest in the vertical direction (11-13%). No systematic bias were evident in the Bland and Altman graphs. The Microsoft Kinect™ system provides comparable data to a video-based 3D motion analysis system when assessing step length and less accurate but still clinically acceptable for step times during balance recovery when balance is lost and fall is initiated.

  12. Friction of atomically stepped surfaces

    NASA Astrophysics Data System (ADS)

    Dikken, R. J.; Thijsse, B. J.; Nicola, L.

    2017-03-01

    The friction behavior of atomically stepped metal surfaces under contact loading is studied using molecular dynamics simulations. While real rough metal surfaces involve roughness at multiple length scales, the focus of this paper is on understanding friction of the smallest scale of roughness: atomic steps. To this end, periodic stepped Al surfaces with different step geometry are brought into contact and sheared at room temperature. Contact stress that continuously tries to build up during loading, is released with fluctuating stress drops during sliding, according to the typical stick-slip behavior. Stress release occurs not only through local slip, but also by means of step motion. The steps move along the contact, concurrently resulting in normal migration of the contact. The direction of migration depends on the sign of the step, i.e., its orientation with respect to the shearing direction. If the steps are of equal sign, there is a net migration of the entire contact accompanied by significant vacancy generation at room temperature. The stick-slip behavior of the stepped contacts is found to have all the characteristic of a self-organized critical state, with statistics dictated by step density. For the studied step geometries, frictional sliding is found to involve significant atomic rearrangement through which the contact roughness is drastically changed. This leads for certain step configurations to a marked transition from jerky sliding motion to smooth sliding, making the final friction stress approximately similar to that of a flat contact.

  13. Isometric and isokinetic muscle strength in the upper extremity can be reliably measured in persons with chronic stroke.

    PubMed

    Ekstrand, Elisabeth; Lexell, Jan; Brogårdh, Christina

    2015-09-01

    To evaluate the test-retest reliability of isometric and isokinetic muscle strength measurements in the upper extremity after stroke. A test-retest design. Forty-five persons with mild to moderate paresis in the upper extremity > 6 months post-stroke. Isometric arm strength (shoulder abduction, elbow flexion), isokinetic arm strength (elbow extension/flexion) and isometric grip strength were measured with electronic dynamometers. Reliability was evaluated with intra-class correlation coefficients (ICC), changes in the mean, standard error of measurements (SEM) and smallest real differences (SRD). Reliability was high (ICCs: 0.92-0.97). The absolute and relative (%) SEM ranged from 2.7 Nm (5.6%) to 3.0 Nm (9.4%) for isometric arm strength, 2.6 Nm (7.4%) to 2.9 Nm (12.6%) for isokinetic arm strength, and 22.3 N (7.6%) to 26.4 N (9.2%) for grip strength. The absolute and relative (%) SRD ranged from 7.5 Nm (15.5%) to 8.4 Nm (26.1%) for isometric arm strength, 7.1 Nm (20.6%) to 8.0 Nm (34.8%) for isokinetic arm strength, and 61.8 N (21.0%) to 73.3 N (25.6%) for grip strength. Muscle strength in the upper extremity can be reliably measured in persons with chronic stroke. Isometric measurements yield smaller measurement errors than isokinetic measurements and might be preferred, but the choice depends on the research question.

  14. Biosonar resolving power: echo-acoustic perception of surface structures in the submillimeter range.

    PubMed

    Simon, Ralph; Knörnschild, Mirjam; Tschapka, Marco; Schneider, Annkathrin; Passauer, Nadine; Kalko, Elisabeth K V; von Helversen, Otto

    2014-01-01

    The minimum distance for which two points still can be separated from each other defines the resolving power of a visual system. In an echo-acoustic context, the resolving power is usually measured as the smallest perceivable distance of two reflecting surfaces on the range axis and is found to be around half a millimeter for bats employing frequency modulated (FM) echolocation calls. Only few studies measured such thresholds with physical objects, most often bats were trained on virtual echoes i.e., echoes generated and played back by a computer; moreover, bats were sitting while they received the stimuli. In these studies differences in structure depth between 200 and 340 μm were found. However, these low thresholds were never verified for free-flying bats and real physical objects. Here, we show behavioral evidence that the echo-acoustic resolving power for surface structures in fact can be as low as measured for computer generated echoes and even lower, sometimes below 100 μm. We found this exceptional fine discrimination ability only when one of the targets showed spectral interferences in the frequency range of the bats' echolocation call while the other target did not. This result indicates that surface structure is likely to be perceived as a spectral quality rather than being perceived strictly in the time domain. Further, it points out that sonar resolving power directly depends on the highest frequency/shortest wavelength of the signal employed.

  15. Finite Element Method-Based Kinematics and Closed-Loop Control of Soft, Continuum Manipulators.

    PubMed

    Bieze, Thor Morales; Largilliere, Frederick; Kruszewski, Alexandre; Zhang, Zhongkai; Merzouki, Rochdi; Duriez, Christian

    2018-06-01

    This article presents a modeling methodology and experimental validation for soft manipulators to obtain forward kinematic model (FKM) and inverse kinematic model (IKM) under quasi-static conditions (in the literature, these manipulators are usually classified as continuum robots. However, their main characteristic of interest in this article is that they create motion by deformation, as opposed to the classical use of articulations). It offers a way to obtain the kinematic characteristics of this type of soft robots that is suitable for offline path planning and position control. The modeling methodology presented relies on continuum mechanics, which does not provide analytic solutions in the general case. Our approach proposes a real-time numerical integration strategy based on finite element method with a numerical optimization based on Lagrange multipliers to obtain FKM and IKM. To reduce the dimension of the problem, at each step, a projection of the model to the constraint space (gathering actuators, sensors, and end-effector) is performed to obtain the smallest number possible of mathematical equations to be solved. This methodology is applied to obtain the kinematics of two different manipulators with complex structural geometry. An experimental comparison is also performed in one of the robots, between two other geometric approaches and the approach that is showcased in this article. A closed-loop controller based on a state estimator is proposed. The controller is experimentally validated and its robustness is evaluated using Lypunov stability method.

  16. Biosonar resolving power: echo-acoustic perception of surface structures in the submillimeter range

    PubMed Central

    Simon, Ralph; Knörnschild, Mirjam; Tschapka, Marco; Schneider, Annkathrin; Passauer, Nadine; Kalko, Elisabeth K. V.; von Helversen, Otto

    2014-01-01

    The minimum distance for which two points still can be separated from each other defines the resolving power of a visual system. In an echo-acoustic context, the resolving power is usually measured as the smallest perceivable distance of two reflecting surfaces on the range axis and is found to be around half a millimeter for bats employing frequency modulated (FM) echolocation calls. Only few studies measured such thresholds with physical objects, most often bats were trained on virtual echoes i.e., echoes generated and played back by a computer; moreover, bats were sitting while they received the stimuli. In these studies differences in structure depth between 200 and 340 μm were found. However, these low thresholds were never verified for free-flying bats and real physical objects. Here, we show behavioral evidence that the echo-acoustic resolving power for surface structures in fact can be as low as measured for computer generated echoes and even lower, sometimes below 100 μm. We found this exceptional fine discrimination ability only when one of the targets showed spectral interferences in the frequency range of the bats′ echolocation call while the other target did not. This result indicates that surface structure is likely to be perceived as a spectral quality rather than being perceived strictly in the time domain. Further, it points out that sonar resolving power directly depends on the highest frequency/shortest wavelength of the signal employed. PMID:24616703

  17. High-resolution light microscopy of nanoforms

    NASA Astrophysics Data System (ADS)

    Vodyanoy, Vitaly; Pustovyy, Oleg; Vainrub, Arnold

    2007-09-01

    We developed a high resolution light imaging system. Diffraction gratings with 100 nm width lines as well as less than 100 nm size features of different-shaped objects are clearly visible on a calibrated microscope test slide (Vainrub et al., Optics Letters, 2006, 31, 2855). The two-point resolution increase results from a known narrowing of the central diffraction peak for the annular aperture. Better visibility and advanced contrast of the smallest features in the image are due to enhancement of high spatial frequencies in the optical transfer function. The imaging system is portable, low energy, and battery operated. It has been adapted to use in both transmitting and reflecting light. It is particularly applicable for motile nanoform systems where structure and functions can be depicted in real time. We have isolated micrometer and submicrometer particles, termed proteons, from human and animal blood. Proteons form by reversible seeded aggregation of proteins around proteon nucleating centers (PNCs). PNCs are comprised of 1-2nm metallic nanoclusters containing 40-300 atoms. Proteons are capable of spontaneous assembling into higher nanoform systems assuming structure of complicated topology. The arrangement of complex proteon system mimics the structure of a small biological cell. It has structures that imitate membrane and nucleolus or nuclei. Some of these nanoforms are motile. They interact and divide. Complex nanoform systems can spontaneously reduce to simple proteons. The physical properties of these nanoforms could shed some light on the properties of early life forms or forms at extreme conditions.

  18. SU-E-J-91: FFT Based Medical Image Registration Using a Graphics Processing Unit (GPU).

    PubMed

    Luce, J; Hoggarth, M; Lin, J; Block, A; Roeske, J

    2012-06-01

    To evaluate the efficiency gains obtained from using a Graphics Processing Unit (GPU) to perform a Fourier Transform (FT) based image registration. Fourier-based image registration involves obtaining the FT of the component images, and analyzing them in Fourier space to determine the translations and rotations of one image set relative to another. An important property of FT registration is that by enlarging the images (adding additional pixels), one can obtain translations and rotations with sub-pixel resolution. The expense, however, is an increased computational time. GPUs may decrease the computational time associated with FT image registration by taking advantage of their parallel architecture to perform matrix computations much more efficiently than a Central Processor Unit (CPU). In order to evaluate the computational gains produced by a GPU, images with known translational shifts were utilized. A program was written in the Interactive Data Language (IDL; Exelis, Boulder, CO) to performCPU-based calculations. Subsequently, the program was modified using GPU bindings (Tech-X, Boulder, CO) to perform GPU-based computation on the same system. Multiple image sizes were used, ranging from 256×256 to 2304×2304. The time required to complete the full algorithm by the CPU and GPU were benchmarked and the speed increase was defined as the ratio of the CPU-to-GPU computational time. The ratio of the CPU-to- GPU time was greater than 1.0 for all images, which indicates the GPU is performing the algorithm faster than the CPU. The smallest improvement, a 1.21 ratio, was found with the smallest image size of 256×256, and the largest speedup, a 4.25 ratio, was observed with the largest image size of 2304×2304. GPU programming resulted in a significant decrease in computational time associated with a FT image registration algorithm. The inclusion of the GPU may provide near real-time, sub-pixel registration capability. © 2012 American Association of Physicists in Medicine.

  19. Changes in bone resorption across the menopause transition: effects of reproductive hormones, body size, and ethnicity.

    PubMed

    Sowers, MaryFran R; Zheng, Huiyong; Greendale, Gail A; Neer, Robert M; Cauley, Jane A; Ellis, Jayne; Johnson, Sarah; Finkelstein, Joel S

    2013-07-01

    Our objective was to characterize changes in bone resorption in relation to the final menstrual period (FMP), reproductive hormones, body mass index (BMI), and ethnicity. Urinary type I collagen N-telopeptide (NTX), estradiol, and FSH levels were measured annually for up to 8 years spanning the menopause transition in 918 African American, Chinese, Japanese, or Caucasian women. Urinary NTX began to increase sharply about 2 years before the FMP, reaching its peak level about 1 to 1.5 years after the FMP. NTX levels declined modestly from 2 to 6 years after the FMP but remained about 20% higher than before the menopause transition. The sharp rise in FSH occurred in conjunction with a sharp decline in estradiol and shortly after FSH levels began increasing rapidly. The mean increase in urinary NTX across the menopause transition was greatest in women with BMI <25 kg/m² and smallest in women with BMI >30 kg/m². Increases in NTX were greatest in Japanese women and smallest in African Americans. These differences were attenuated, but not eliminated, when analyses were adjusted for covariates, particularly BMI. During the menopause transition, a decline in ovarian function beginning about 2 years before the FMP is followed by an increase in bone resorption and subsequently by bone loss. The magnitude of the increase in bone resorption is inversely associated with BMI. Ethnic differences in changes in bone resorption are attenuated, but not eliminated, by adjustment for BMI. Ethnic differences in BMI, and corresponding ethnic differences in bone resorption, appear to account for much of the ethnic variation in perimenopausal bone loss.

  20. Ensemble forecasting of short-term system scale irrigation demands using real-time flow data and numerical weather predictions

    NASA Astrophysics Data System (ADS)

    Perera, Kushan C.; Western, Andrew W.; Robertson, David E.; George, Biju; Nawarathna, Bandara

    2016-06-01

    Irrigation demands fluctuate in response to weather variations and a range of irrigation management decisions, which creates challenges for water supply system operators. This paper develops a method for real-time ensemble forecasting of irrigation demand and applies it to irrigation command areas of various sizes for lead times of 1 to 5 days. The ensemble forecasts are based on a deterministic time series model coupled with ensemble representations of the various inputs to that model. Forecast inputs include past flow, precipitation, and potential evapotranspiration. These inputs are variously derived from flow observations from a modernized irrigation delivery system; short-term weather forecasts derived from numerical weather prediction models and observed weather data available from automatic weather stations. The predictive performance for the ensemble spread of irrigation demand was quantified using rank histograms, the mean continuous rank probability score (CRPS), the mean CRPS reliability and the temporal mean of the ensemble root mean squared error (MRMSE). The mean forecast was evaluated using root mean squared error (RMSE), Nash-Sutcliffe model efficiency (NSE) and bias. The NSE values for evaluation periods ranged between 0.96 (1 day lead time, whole study area) and 0.42 (5 days lead time, smallest command area). Rank histograms and comparison of MRMSE, mean CRPS, mean CRPS reliability and RMSE indicated that the ensemble spread is generally a reliable representation of the forecast uncertainty for short lead times but underestimates the uncertainty for long lead times.

  1. Impact of nonlinear effective interactions on group field theory quantum gravity condensates

    NASA Astrophysics Data System (ADS)

    Pithis, Andreas G. A.; Sakellariadou, Mairi; Tomov, Petar

    2016-09-01

    We present the numerical analysis of effectively interacting group field theory models in the context of the group field theory quantum gravity condensate analog of the Gross-Pitaevskii equation for real Bose-Einstein condensates including combinatorially local interaction terms. Thus, we go beyond the usually considered construction for free models. More precisely, considering such interactions in a weak regime, we find solutions for which the expectation value of the number operator N is finite, as in the free case. When tuning the interaction to the strongly nonlinear regime, however, we obtain solutions for which N grows and eventually blows up, which is reminiscent of what one observes for real Bose-Einstein condensates, where a strong interaction regime can only be realized at high density. This behavior suggests the breakdown of the Bogoliubov ansatz for quantum gravity condensates and the need for non-Fock representations to describe the system when the condensate constituents are strongly correlated. Furthermore, we study the expectation values of certain geometric operators imported from loop quantum gravity in the free and interacting cases. In particular, computing solutions around the nontrivial minima of the interaction potentials, one finds, already in the weakly interacting case, a nonvanishing condensate population for which the spectra are dominated by the lowest nontrivial configuration of the quantum geometry. This result indicates that the condensate may indeed consist of many smallest building blocks giving rise to an effectively continuous geometry, thus suggesting the interpretation of the condensate phase to correspond to a geometric phase.

  2. In vivo reproducibility of robotic probe placement for a novel ultrasound-guided radiation therapy system

    PubMed Central

    Lediju Bell, Muyinatu A.; Sen, H. Tutkun; Iordachita, Iulian; Kazanzides, Peter; Wong, John

    2014-01-01

    Abstract. Ultrasound can provide real-time image guidance of radiation therapy, but the probe-induced tissue deformations cause local deviations from the treatment plan. If placed during treatment planning, the probe causes streak artifacts in required computed tomography (CT) images. To overcome these challenges, we propose robot-assisted placement of an ultrasound probe, followed by replacement with a geometrically identical, CT-compatible model probe. In vivo reproducibility was investigated by implanting a canine prostate, liver, and pancreas with three 2.38-mm spherical markers in each organ. The real probe was placed to visualize the markers and subsequently replaced with the model probe. Each probe was automatically removed and returned to the same position or force. Under position control, the median three-dimensional reproducibility of marker positions was 0.6 to 0.7 mm, 0.3 to 0.6 mm, and 1.1 to 1.6 mm in the prostate, liver, and pancreas, respectively. Reproducibility was worse under force control. Probe substitution errors were smallest for the prostate (0.2 to 0.6 mm) and larger for the liver and pancreas (4.1 to 6.3 mm), where force control generally produced larger errors than position control. Results indicate that position control is better than force control for this application, and the robotic approach has potential, particularly for relatively constrained organs and reproducibility errors that are smaller than established treatment margins. PMID:26158038

  3. Attractiveness Differences Between Twins Predicts Evaluations of Self and Co-Twin

    PubMed Central

    Principe, Connor P.; Rosen, Lisa H.; Taylor-Partridge, Teresa; Langlois, Judith H.

    2012-01-01

    One of the most consistent findings in psychology shows that people prefer and make positive attributions about attractive compared with unattractive people. The goal of the current study was to determine the power of attractiveness effects by testing whether these social judgments are made where attractiveness differences are smallest: between twins. Differences in facial attractiveness predicted twins’ evaluations of self and their co-twin (n = 158; 54 male). In twin pairs, the more attractive twin judged their less attractive sibling as less physically attractive, athletic, socially competent, and emotionally stable. The less attractive twin did the reverse. Given that even negligible differences in facial attractiveness predicted self and co-twin attitudes, these results provide the strongest test yet of appearance-based stereotypes. PMID:23467329

  4. Application of LANDSAT imagery for snow mapping in Norway

    NASA Technical Reports Server (NTRS)

    Odegaard, H. (Principal Investigator); Ostrem, G.

    1977-01-01

    The author has identified the following significant results. It was shown that if the snow cover extent was determined from all four LANDSAT bands, there were significant differences in results. The MSS 4 gave the largest snow cover, but only slightly more than MSS 5, whereas MSS 6 and 7 gave the smallest snow area. A study was made to show that there was a relationship between the last date of snow fall and the area covered with snow, as determined from different bands. Imagery obtained shortly after a snow fall showed no significant difference in the snow-covered area when the four bans were compared, whereas, pronounced differences in the snow-covered area were found in images taken after a long period without precipitation.

  5. The impact of computed tomography slice thickness on the assessment of stereotactic, 3D conformal and intensity-modulated radiotherapy of brain tumors.

    PubMed

    Caivano, R; Fiorentino, A; Pedicini, P; Califano, G; Fusco, V

    2014-05-01

    To evaluate radiotherapy treatment planning accuracy by varying computed tomography (CT) slice thickness and tumor size. CT datasets from patients with primary brain disease and metastatic brain disease were selected. Tumor volumes ranging from about 2.5 to 100 cc and CT scan at different slice thicknesses (1, 2, 4, 6 and 10 mm) were used to perform treatment planning (1-, 2-, 4-, 6- and 10-CT, respectively). For any slice thickness, a conformity index (CI) referring to 100, 98, 95 and 90 % isodoses and tumor size was computed. All the CI and volumes obtained were compared to evaluate the impact of CT slice thickness on treatment plans. The smallest volumes reduce significantly if defined on 1-CT with respect to 4- and 6-CT, while the CT slice thickness does not affect target definition for the largest volumes. The mean CI for all the considered isodoses and CT slice thickness shows no statistical differences when 1-CT is compared to 2-CT. Comparing the mean CI of 1- with 4-CT and 1- with 6-CT, statistical differences appear only for the smallest volumes with respect to 100, 98 and 95 % isodoses-the CI for 90 % isodose being not statistically significant for all the considered PTVs. The accuracy of radiotherapy tumor volume definition depends on CT slice thickness. To achieve a better tumor definition and dose coverage, 1- and 2-CT would be suitable for small targets, while 4- and 6-CT are suitable for the other volumes.

  6. A new species of Leptolalax (Amphibia, Anura, Megophryidae) from Peninsular Malaysia.

    PubMed

    Matsui, Masafumi; Belabut, Daicus M; Ahmad, Norhayati; Yong, Hoi-Sen

    2009-03-01

    A new megophryid species, Leptolalax kecil, is described from the Cameron Highlands of Peninsular Malaysia on the basis of acoustic and morphological characteristics. It has an advertisement call dissimilar to that of other, congeneric species, and is the smallest of the known Leptolalax. It is similar to L. pluvialis from Vietnam in small body size, but differs from it in ventral color, and in the size and color of the pectoral gland. The distributional pattern of the new species Is discussed.

  7. Reynolds Number Effects on Thrust Coefficients and PIV for Flapping Wing Micro Air Vehicles

    DTIC Science & Technology

    2012-03-09

    flapper and smallest gear attached to the drive shaft from the motor. Lastly, passive rotation stops were designed and printed using the Objet Eden 500V...for different flapping mechanisms are also compared to a rotating propeller with the goal of elucidating the design trade space between rotorcraft and...flapping wings at Reynolds numbers less than 100,000. One flapping-wing mechanism was designed to incorporate a coupled 4-bar planar and 4-bar

  8. New early Pleistocene hominin teeth from the Swartkrans Formation, South Africa.

    PubMed

    Pickering, Travis Rayne; Heaton, Jason L; Sutton, Morris B; Clarke, Ron J; Kuman, Kathleen; Senjem, Jess Hutton; Brain, C K

    2016-11-01

    We describe 14 hominin teeth and tooth fragments excavated recently from Swartkrans Cave (South Africa). The fossils derive from Members 1 (Lower Bank) and 3, from the Member 2/3 interface and from two deposits not yet assigned to member (the "Talus Cone Deposit" and the "Underground North Excavation" [UNE]) of the Swartkrans Formation, and include the first hominin fossil from the UNE, the two smallest Paranthropus robustus deciduous maxillary second molars in the entire hominin fossil record, and one of the smallest P. robustus permanent maxillary second molars from Swartkrans. The small permanent molar is accompanied by another tooth from a different individual but from the same stratigraphic level of the Swartkrans Formation; this second tooth is among, if not, the largest P. robustus permanent maxillary first molars known from anywhere-lending credence to assertions that degrees of body size sexual dimorphism previously ascribed to this species may be underestimated. It is more equivocal whether this evidence also supports hypotheses proposing that P. robustus assemblages from Swartkrans (as well as those from other South African cave sites) formed through the taphonomically biasing actions of large carnivores. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Robust geographically weighted regression of modeling the Air Polluter Standard Index (APSI)

    NASA Astrophysics Data System (ADS)

    Warsito, Budi; Yasin, Hasbi; Ispriyanti, Dwi; Hoyyi, Abdul

    2018-05-01

    The Geographically Weighted Regression (GWR) model has been widely applied to many practical fields for exploring spatial heterogenity of a regression model. However, this method is inherently not robust to outliers. Outliers commonly exist in data sets and may lead to a distorted estimate of the underlying regression model. One of solution to handle the outliers in the regression model is to use the robust models. So this model was called Robust Geographically Weighted Regression (RGWR). This research aims to aid the government in the policy making process related to air pollution mitigation by developing a standard index model for air polluter (Air Polluter Standard Index - APSI) based on the RGWR approach. In this research, we also consider seven variables that are directly related to the air pollution level, which are the traffic velocity, the population density, the business center aspect, the air humidity, the wind velocity, the air temperature, and the area size of the urban forest. The best model is determined by the smallest AIC value. There are significance differences between Regression and RGWR in this case, but Basic GWR using the Gaussian kernel is the best model to modeling APSI because it has smallest AIC.

  10. Influence of fault steps on rupture termination of strike-slip earthquake faults

    NASA Astrophysics Data System (ADS)

    Li, Zhengfang; Zhou, Bengang

    2018-03-01

    A statistical analysis was completed on the rupture data of 29 historical strike-slip earthquakes across the world. The purpose of this study is to examine the effects of fault steps on the rupture termination of these events. The results show good correlations between the type and length of steps with the seismic rupture and a poor correlation between the step number and seismic rupture. For different magnitude intervals, the smallest widths of the fault steps (Lt) that can terminate the rupture propagation are variable: Lt = 3 km for Ms 6.5 6.9, Lt = 4 km for Ms 7.0 7.5, Lt = 6 km for Ms 7.5 8.0, and Lt = 8 km for Ms 8.0 8.5. The dilational fault step is easier to rupture through than the compression fault step. The smallest widths of the fault step for the rupture arrest can be used as an indicator to judge the scale of the rupture termination of seismic faults. This is helpful for research on fault segmentation, as well as estimating the magnitude of potential earthquakes, and is thus of significance for the assessment of seismic risks.

  11. The modified swirl sedimentation tanks for water purification.

    PubMed

    Ochowiak, Marek; Matuszak, Magdalena; Włodarczak, Sylwia; Ancukiewicz, Małgorzata; Krupińska, Andżelika

    2017-03-15

    This paper discusses design, evaluation, and application for the use of swirl/vortex technologies as liquid purification system. A study was performed using modified swirl sedimentation tanks. The vortex separators (OW, OWK, OWR and OWKR) have been studied under laboratory conditions at liquid flow rate from 2.8⋅10 -5 to 5.1⋅10 -4 [m 3 /s]. The pressure drop and the efficiency of purification of liquid stream were analyzed. The suspended particles of different diameters were successfully removed from liquid with the application of swirl chambers of proposed constructions. It was found that damming of liquid in the tank increases alongside liquid stream at the inlet and depends on the tank construction. The efficiency of the sedimentation tanks increases alongside the diameters of solid particles and decrease in the liquid flow rate. The best construction proved to be the OWR sedimentation tank due to smallest liquid damming, even at high flow rates, and the highest efficiency of the purification liquid stream for solid particles of the smallest diameter. The proposed solution is an alternative to the classical constructions of sedimentation tanks. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Experimental investigation of air pressure affecting filtration performance of fibrous filter sheet.

    PubMed

    Xu, Bin; Yu, Xiao; Wu, Ya; Lin, Zhongping

    2017-03-01

    Understanding the effect of air pressure on their filtration performance is important for assessing the effectiveness of fibrous filters under different practical circumstances. The effectiveness of three classes of air filter sheets were investigated in laboratory-based measurements at a wide range of air pressures (60-130 KPa). The filtration efficiency was found most sensitive to the air pressure change at smaller particle sizes. As the air pressure increased from 60 to 130 KPa, significant decrease in filtration efficiency (up to 15%) and increase in pressure drop (up to 90 Pa) were observed. The filtration efficiency of the filter sheet with largest fiber diameter and smallest solid volume fraction was affected most, while the pressure drop of the filter sheet with smallest fiber diameter and largest solid volume fraction was affected most. The effect of air pressure on the filtration efficiency was slightly larger at greater filter face air velocity. However, the effect of air pressure on the pressure drop was negligible. The filtration efficiency and pressure drop were explicitly expressed as functions of the air pressure. Two coefficients were empirically derived and successfully accounted for the effects of air pressure on filtration efficiency and pressure drop.

  13. Folding Free Energy Landscape of the Decapeptide Chignolin

    NASA Astrophysics Data System (ADS)

    Dou, Xianghua; Wang, Jihua

    Chignolin is an artificially designed ten-residue (GYDPETGTWG) folded peptide, which is the smallest protein and provides a good template for protein folding. In this work, we completed four explicit water molecular dynamics simulations of Chignolin folding using GROMOS and OPLS-AA force fields from extended initial states without any experiment informations. The four-folding free energy landscapes of the peptide has been drawn. The folded state of Chignolin has been successfully predicated based on the free energy landscapes. The four independent simulations gave similar results. (i) The four free energy landscapes have common characters. They are fairly smooth, barrierless, funnel-like and downhill without intermediate state, which consists with the experiment. (ii) The different extended initial structures converge at similar folded structures with the lowest free energy under GROMOS and OPLS-AA force fields. In the GROMOS force field, the backbone RMSD of the folded structures from the NMR native structure of Chignolin is only 0.114 nm, which is a stable structure in this force field. In the OPLS-AA force field, the similar results have been obtained. In addition, the smallest RMSD structure is in better agreement with the NMR native structure but unlikely stable in the force field.

  14. SU-F-T-577: Comparison of Small Field Dosimetry Measurements in Fields Shaped with Conical Applicators On Two Different Accelerating Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muir, B; McEwen, M; Belec, J

    2016-06-15

    Purpose: To investigate small field dosimetry measurements and associated uncertainties when conical applicators are used to shape treatment fields from two different accelerating systems. Methods: Output factor measurements are made in water in beams from the CyberKnife radiosurgery system, which uses conical applicators to shape fields from a (flattening filter-free) 6 MV beam, and in a 6 MV beam from the Elekta Precise linear accelerator (with flattening filter) with BrainLab external conical applicators fitted to shape the field. The measurements use various detectors: (i) an Exradin A16 ion chamber, (ii) two Exradin W1 plastic scintillation detectors, (iii) a Sun Nuclearmore » Edge diode, and (iv) two PTW microDiamond synthetic diamond detectors. Profiles are used for accurate detector positioning and to specify field size (FWHM). Output factor measurements are corrected with detector specific correction factors taken from the literature where available and/or from Monte Carlo simulations using the EGSnrc code system. Results: Differences in measurements of up to 1.7% are observed with a given detector type in the same beam (i.e., intra-detector variability). Corrected results from different detectors in the same beam (inter-detector differences) show deviations up to 3 %. Combining data for all detectors and comparing results from the two accelerators results in a 5.9% maximum difference for the smallest field sizes (FWHM=5.2–5.6 mm), well outside the combined uncertainties (∼1% for the smallest beams) and/or differences among detectors. This suggests that the FWHM of a measured profile is not a good specifier to compare results from different small fields with the same nominal energy. Conclusion: Large differences in results for both intra-detector variability and inter-detector differences suggest potentially high uncertainties in detector-specific correction factors. Differences between the results measured in circular fields from different accelerating systems provide insight into sources of variability in small field dosimetric measurements reported in the literature.« less

  15. Cyborg mini-trainer.

    PubMed

    Mosso, José L; Nieto, Jesus J; Carbajal, Manuel F; Marmolejo, Jorge; Ochoa, Enrique; De La Fuente, Mireya; Almazan, Andrew; Obrador, Tomas

    2009-01-01

    We present the smallest surgical trainer with a total weight of 400 gr, built in aluminum of 25 cm large and 24 cm wide, and 23 cm high. It's a system integrated by a small and open module, a lamp and a microcamera connected to a Head Mounted display. It holds two endoscopic instruments, and items to make knots or sutures and enhance visual-motor coordination. The vision we got is by a small microcamera displayed to a Head Mounted Display HMD. This surgical trainer is the smallest in the worldwide, easy to install, and easy to carry.

  16. 34 CFR 222.68 - What tax rates does the Secretary use if two or more different classifications of real property...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... different classifications of real property are taxed at different rates? 222.68 Section 222.68 Education... different classifications of real property are taxed at different rates? If the real property of an LEA and its generally comparable LEAs consists of two or more classifications of real property taxed at...

  17. Comparative investigations on ferrite nanocomposites for magnetic hyperthermia applications

    NASA Astrophysics Data System (ADS)

    El-Dek, S. I.; Ali, Maha A.; El-Zanaty, Sara M.; Ahmed, Shehab E.

    2018-07-01

    Superparamagnetic iron oxide nanoparticles (SPION) Fe3O4 nanoparticles were prepared using different approaches: co-precipitation and sonochemical methods. This article is a comparative study on how different synthesis techniques greatly affect the magnetic properties and heating efficiency of such nanomaterial. Another important issue addressed here is the correlation between microstructure, colloidal stability, magnetization and specific absorption rate (SAR) of the nanoparticles. The results reveal that the sonochemical method for polyethylene glycol (PEGylated) Fe3O4 with size 5 nm leads to pseudo single domain with smallest loop area. Additionally, large SAR values are obtained within 10-15 min using low magnetic field.

  18. Seed harvesting by a generalist consumer is context-dependent: Interactive effects across multiple spatial scales

    USGS Publications Warehouse

    Ostoja, Steven M.; Schupp, Eugene W.; Klinger, Rob

    2013-01-01

    Granivore foraging decisions affect consumer success and determine the quantity and spatial pattern of seed survival. These decisions are influenced by environmental variation at spatial scales ranging from landscapes to local foraging patches. In a field experiment, the effects of seed patch variation across three spatial scales on seed removal by western harvester ants Pogonomyrmex occidentalis were evaluated. At the largest scale we assessed harvesting in different plant communities, at the intermediate scale we assessed harvesting at different distances from ant mounds, and at the smallest scale we assessed the effects of interactions among seed species in local seed neighborhoods on seed harvesting (i.e. resource–consumer interface). Selected seed species were presented alone (monospecific treatment) and in mixture with Bromus tectorum (cheatgrass; mixture treatment) at four distances from P. occidentalis mounds in adjacent intact sagebrush and non-native cheatgrass-dominated communities in the Great Basin, Utah, USA. Seed species differed in harvest, with B. tectorum being least preferred. Large and intermediate scale variation influenced harvest. More seeds were harvested in sagebrush than in cheatgrass-dominated communities (largest scale), and the quantity of seed harvested varied with distance from mounds (intermediate-scale), although the form of the distance effect differed between plant communities. At the smallest scale, seed neighborhood affected harvest, but the patterns differed among seed species considered. Ants harvested fewer seeds from mixed-seed neighborhoods than from monospecific neighborhoods, suggesting context dependence and potential associational resistance. Further, the effects of plant community and distance from mound on seed harvest in mixtures differed from their effects in monospecific treatments. Beyond the local seed neighborhood, selection of seed resources is better understood by simultaneously evaluating removal at multiple scales. Associational effects provide a useful theoretical basis for better understanding harvester ant foraging decisions. These results demonstrate the importance of ecological context for seed removal, which has implications for seed pools, plant populations and communities.

  19. A review of tephra transport and dispersal models: Evolution, current status, and future perspectives

    NASA Astrophysics Data System (ADS)

    Folch, A.

    2012-08-01

    Tephra transport models try to predict atmospheric dispersion and sedimentation of tephra depending on meteorology, particle properties, and eruption characteristics, defined by eruption column height, mass eruption rate, and vertical distribution of mass. Models are used for different purposes, from operational forecast of volcanic ash clouds to hazard assessment of tephra dispersion and fallout. The size of the erupted particles, a key parameter controlling the dynamics of particle sedimentation in the atmosphere, varies within a wide range. Largest centimetric to millimetric particles fallout at proximal to medial distances from the volcano and sediment by gravitational settling. On the other extreme, smallest micrometric to sub-micrometric particles can be transported at continental or even at global scales and are affected by other deposition and aggregation mechanisms. Different scientific communities had traditionally modeled the dispersion of these two end members. Volcanologists developed families of models suitable for lapilli and coarse ash and aimed at computing fallout deposits and for hazard assessment. In contrast, meteorologists and atmospheric scientists have traditionally used other atmospheric transport models, dealing with finer particles, for tracking motion of volcanic ash clouds and, eventually, for computing airborne ash concentrations. During the last decade, the increasing demand for model accuracy and forecast reliability has pushed on two fronts. First, the original gap between these different families of models has been filled with the emergence of multi-scale and multi-purpose models. Second, new modeling strategies including, for example, ensemble and probabilistic forecast or model data assimilation are being investigated for future implementation in models and or modeling strategies. This paper reviews the evolution of tephra transport and dispersal models during the last two decades, presents the status and limitations of the current modeling strategies, and discusses some emergent perspectives expected to be implemented at operational level during the next few years. Improvements in both real-time forecasting and long-term hazard assessment are necessary to loss prevention programs on a local, regional, national and international level.

  20. Handgrip force steadiness in young and older adults: a reproducibility study.

    PubMed

    Blomkvist, Andreas W; Eika, Fredrik; de Bruin, Eling D; Andersen, Stig; Jorgensen, Martin

    2018-04-02

    Force steadiness is a quantitative measure of the ability to control muscle tonus. It is an independent predictor of functional performance and has shown to correlate well with different degrees of motor impairment following stroke. Despite being clinically relevant, few studies have assessed the validity of measuring force steadiness. The aim of this study was to explore the reproducibility of handgrip force steadiness, and to assess age difference in steadiness. Intrarater reproducibility (the degree to which a rating gives consistent result on separate occasions) was investigated in a test-retest design with seven days between sessions. Ten young and thirty older adults were recruited and handgrip steadiness was tested at 5%, 10% and 25% of maximum voluntary contraction (MVC) using Nintendo Wii Balance Board (WBB). Coefficients of variation were calculated from the mean force produced (CVM) and the target force (CVT). Area between the force curve and the target force line (Area) was also calculated. For the older adults we explored reliability using intraclass correlation coefficient (ICC) and agreement using standard error of measurement (SEM), limits of agreement (LOA) and smallest real difference (SRD). A systematic improvement in handgrip steadiness was found between sessions for all measures (CVM, CVT, Area). CVM and CVT at 5% of MVC showed good to high reliability, while Area had poor reliability for all percentages of MVC. Averaged ICC for CVM, CVT and Area was 0.815, 0.806 and 0.464, respectively. Averaged ICC on 5%, 10%, and 25% of MVC was 0.751, 0.667 and 0.668, respectively. Measures of agreement showed similar trends with better results for CVM and CVT than for Area. Young adults had better handgrip steadiness than older adults across all measures. The CVM and CVT measures demonstrated good reproducibility at lower percentages of MVC using the WBB, and could become relevant measures in the clinical setting. The Area measure had poor reproducibility. Young adults have better handgrip steadiness than old adults.

  1. Facial esthetics and the assignment of personality traits before and after orthognathic surgery rated on video clips

    PubMed Central

    Jagsch, Reinhold; Drog, Claudio; Mosgoeller, Wilhelm; Wutzl, Arno; Millesi, Gabriele; Klug, Clemens

    2018-01-01

    Typically, before and after surgical correction faces are assessed on still images by surgeons, orthodontists, the patients, and family members. We hypothesized that judgment of faces in motion and by naïve raters may closer reflect the impact on patients’ real life, and the treatment impact on e.g. career chances. Therefore we assessed faces from dysgnathic patients (Class II, III and Laterognathia) on video clips. Class I faces served as anchor and controls. Each patient’s face was assessed twice before and after treatment in changing sequence, by 155 naïve raters with similar age to the patients. The raters provided independent estimates on aesthetic trait pairs like ugly /beautiful, and personality trait pairs like dominant /flexible. Furthermore the perception of attractiveness, intelligence, health, the persons’ erotic aura, faithfulness, and five additional items were rated. We estimated the significance of the perceived treatment related differences and the respective effect size by general linear models for repeated measures. The obtained results were comparable to our previous rating on still images. There was an overall trend, that faces in video clips are rated along common stereotypes to a lesser extent than photographs. We observed significant class differences and treatment related changes of most aesthetic traits (e.g. beauty, attractiveness), these were comparable to intelligence, erotic aura and to some extend healthy appearance. While some personality traits (e.g. faithfulness) did not differ between the classes and between baseline and after treatment, we found that the intervention significantly and effectively altered the perception of the personality trait self-confidence. The effect size was highest in Class III patients, smallest in Class II patients, and in between for patients with Laterognathia. All dysgnathic patients benefitted from orthognathic surgery. We conclude that motion can mitigate marked stereotypes but does not entirely offset the mostly negative perception of dysgnathic faces. PMID:29390018

  2. Longitudinal psychometric attributes, responsiveness, and importance of change: An approach using the SCOPA-Psychosocial questionnaire.

    PubMed

    Martínez-Martin, Pablo; Carod-Artal, Francisco Javier; da Silveira Ribeiro, Luciola; Ziomkowski, Sofia; Vargas, Antonio Pedro; Kummer, Wladimir; Mesquita, Hudson Mourão

    2008-08-15

    The objective of this study was to illustrate the analysis of longitudinal validity, responsiveness, and importance of change, using the SCOPA-Psychosocial Questionnaire (SCOPA-PS) as a source of empirical data. Sixty-seven patients with PD in Hoehn and Yahr (HY) stage 2 were followed up for 1 year and assessed by means of the Schwab and England Scale, Unified PD Rating Scale (UPDRS), Hospital Anxiety and Depression Scale (HADS), PDQ-39, and SCOPA-PS. A range of methods was applied to enable each of the target attributes to be analyzed from different conceptual stances. The SCOPA-PS displayed satisfactory acceptability (no floor or ceiling effect), internal consistency (alpha = 0.80-0.84), convergent validity (r(S) = 0.70-0.82 with PDQ-39), and precision (SEM = 8.80), both at baseline and at the end of follow-up. The threshold value for significant change ranged from 17.25 (1.96 SEM) to 24.39 (Smallest real difference and Reliable change index). Threshold values for a clinically meaningful change were 0.73-1.26 (effect size, standardized response mean, responsiveness statistic). Change in SCOPA-PS scores correlated strongly with change in total UPDRS, HADS, and PDQ-39 scores, and reliably detected 70% of cases that worsened according to the PDQ-39. The minimally important change (MIC) for "minimally impaired" patients as per the PDQ39 was 8.30-9.10 points. Indices such as 1.96 SEM, effect size, and correlation with the change in other measures provide useful information about different concepts of responsiveness. The MIC should be determined for each specific setting, using distribution- and anchor-based methods. The SCOPA-PS showed satisfactory longitudinal attributes and responsiveness in stage-2 Brazilian patients with PD across 1 year of follow-up. (c) 2008 Movement Disorder Society.

  3. Multicomponent diffusion in basaltic melts at 1350 °C

    NASA Astrophysics Data System (ADS)

    Guo, Chenghuan; Zhang, Youxue

    2018-05-01

    Nine successful diffusion couple experiments were conducted in an 8-component SiO2-TiO2-Al2O3-FeO-MgO-CaO-Na2O-K2O system at ∼1350 °C and at 1 GPa, to study multicomponent diffusion in basaltic melts. At least 3 traverses were measured to obtain diffusion profiles for each experiment. Multicomponent diffusion matrix at 1350 °C was obtained by simultaneously fitting diffusion profiles of diffusion couple experiments. Furthermore, in order to better constrain the diffusion matrix and reconcile mineral dissolution data, mineral dissolution experiments in the literature and diffusion couple experiments from this study, were fit together. All features of diffusion profiles in both diffusion couple and mineral dissolution experiments were well reproduced by the diffusion matrix. Diffusion mechanism is inferred from eigenvectors of the diffusion matrix, and it shows that the diffusive exchange between network-formers SiO2 and Al2O3 is the slowest, the exchange of SiO2 with other oxide components is the second slowest with an eigenvalue that is only ∼10% larger, then the exchange between divalent oxide components and all the other oxide components is the third slowest with an eigenvalue that is twice the smallest eigenvalue, then the exchange of FeO + K2O with all the other oxide components is the fourth slowest with an eigenvalue that is 5 times the smallest eigenvalue, then the exchange of MgO with FeO + CaO is the third fastest with an eigenvalue that is 6.3 times the smallest eigenvalue, then the exchange of CaO + K2O with all the other oxide components is the second fastest with an eigenvalue that is 7.5 times the smallest eigenvalue, and the exchange of Na2O with all other oxide components is the fastest with an eigenvalue that is 31 times the smallest eigenvalue. The slowest and fastest eigenvectors are consistent with those for simpler systems in most literature. The obtained diffusion matrix was successfully applied to predict diffusion profiles during mineral dissolution in basaltic melts.

  4. Universal Capacitance Model for Real-Time Biomass in Cell Culture.

    PubMed

    Konakovsky, Viktor; Yagtu, Ali Civan; Clemens, Christoph; Müller, Markus Michael; Berger, Martina; Schlatter, Stefan; Herwig, Christoph

    2015-09-02

    : Capacitance probes have the potential to revolutionize bioprocess control due to their safe and robust use and ability to detect even the smallest capacitors in the form of biological cells. Several techniques have evolved to model biomass statistically, however, there are problems with model transfer between cell lines and process conditions. Errors of transferred models in the declining phase of the culture range for linear models around +100% or worse, causing unnecessary delays with test runs during bioprocess development. The goal of this work was to develop one single universal model which can be adapted by considering a potentially mechanistic factor to estimate biomass in yet untested clones and scales. The novelty of this work is a methodology to select sensitive frequencies to build a statistical model which can be shared among fermentations with an error between 9% and 38% (mean error around 20%) for the whole process, including the declining phase. A simple linear factor was found to be responsible for the transferability of biomass models between cell lines, indicating a link to their phenotype or physiology.

  5. The Brazilian decimetric array and space weather

    NASA Astrophysics Data System (ADS)

    Sawant, Hanumant S.; Gopalswamy, Natchimuthuk; Rosa, Reinaldo R.; Sych, Robert A.; Anfinogentov, Sergey A.; Fernandes, Francisco C. R.; Cecatto, José R.; Costa, Joaquim E. R.

    2011-07-01

    We report on the development and current status of the Brazilian Decimetric Array (BDA), which will play a vital role in filling the existing gaps in imaging the Sun at decimetric wavelengths. The BDA will operate in the following radio bands: 1.2-1.7, 2.8, and 5.6 GHz with high spatial and temporal resolutions. BDA can observe flares and coronal mass ejections (CMEs) in a spectral range poorly covered in the past, thus providing important information to space weather science. The smallest baseline of 9 m employed by the BDA combined with high sensitivity will readily identify large-scale structures such as coronal holes and provide information on wave flows from them. New methods are being developed to analyze the solar-disk data with high time resolution by using tomographic and spatial PWF techniques that can readily identify coronal holes in their initial stage. Efforts are also being made to analyze the BDA data in real time in conjunction with SOHO data for a better understanding of CMEs and coronal holes. This paper provides a brief description of the BDA, and the new techniques of data analysis.

  6. Orofacial symptoms related to temporomandibular joint arthritis in juvenile idiopathic arthritis: smallest detectable difference in self-reported pain intensity.

    PubMed

    Stoustrup, Peter; Kristensen, Kasper D; Verna, Carlalberta; Küseler, Annelise; Herlin, Troels; Pedersen, Thomas K

    2012-12-01

    Temporomandibular joint (TMJ) inflammation in patients with juvenile idiopathic arthritis (JIA) may lead to mandibular growth disturbances and interfere with optimal joint and muscle function. Orofacial symptoms are common clinical findings in relation to TMJ arthritis in adolescence. Knowledge about their clinical manifestation is important for TMJ arthritis diagnosis, treatment choice, and outcome evaluation. The aim of our prospective observational study was to evaluate and describe the frequency, the main complaints, and the localization of TMJ arthritis-related orofacial symptoms. The smallest detectable differences (SDD) for minimal, average, and maximal pain were estimated. Thirty-three patients with JIA and arthritis-related orofacial symptoms in relation to 55 affected TMJ were included in our questionnaire study (mean age 14.11 yrs). Calculation of the SDD was based on a duplicate assessment 45 min after the first questionnaire was completed. The majority of the patients had common orofacial symptoms during mastication and maximal mouth opening procedures. Persistent orofacial symptoms were rare. The TMJ area in combination with the masseter muscle region was the orofacial region where symptoms were most common. The SDD for minimal, average, and maximal pain were between 10 and 14 mm on a visual analog scale. Our study offers new knowledge about TMJ arthritis-related orofacial symptoms that may aid diagnosis and clinical decision-making. We suggest that TMJ arthritis-related orofacial symptoms could be understood as products of the primary TMJ inflammation in combination with secondary myogenic and functional issues.

  7. Grapevine acclimation to water deficit: the adjustment of stomatal and hydraulic conductance differs from petiole embolism vulnerability.

    PubMed

    Hochberg, Uri; Bonel, Andrea Giulia; David-Schwartz, Rakefet; Degu, Asfaw; Fait, Aaron; Cochard, Hervé; Peterlunger, Enrico; Herrera, Jose Carlos

    2017-06-01

    Drought-acclimated vines maintained higher gas exchange compared to irrigated controls under water deficit; this effect is associated with modified leaf turgor but not with improved petiole vulnerability to cavitation. A key feature for the prosperity of plants under changing environments is the plasticity of their hydraulic system. In the present research we studied the hydraulic regulation in grapevines (Vitis vinifera L.) that were first acclimated for 39 days to well-watered (WW), sustained water deficit (SD), or transient-cycles of dehydration-rehydration-water deficit (TD) conditions, and then subjected to varying degrees of drought. Vine development under SD led to the smallest leaves and petioles, but the TD vines had the smallest mean xylem vessel and calculated specific conductivity (k ts ). Unexpectedly, both the water deficit acclimation treatments resulted in vines more vulnerable to cavitation in comparison to WW, possibly as a result of developmental differences or cavitation fatigue. When exposed to drought, the SD vines maintained the highest stomatal (g s ) and leaf conductance (k leaf ) under low stem water potential (Ψ s ), despite their high xylem vulnerability and in agreement with their lower turgor loss point (Ψ TLP ). These findings suggest that the down-regulation of k leaf and g s is not associated with embolism, and the ability of drought-acclimated vines to maintain hydraulic conductance and gas exchange under stressed conditions is more likely associated with the leaf turgor and membrane permeability.

  8. Genetic Factors Influencing Coagulation Factor XIII B-Subunit Contribute to Risk of Ischemic Stroke.

    PubMed

    Hanscombe, Ken B; Traylor, Matthew; Hysi, Pirro G; Bevan, Stephen; Dichgans, Martin; Rothwell, Peter M; Worrall, Bradford B; Seshadri, Sudha; Sudlow, Cathie; Williams, Frances M K; Markus, Hugh S; Lewis, Cathryn M

    2015-08-01

    Abnormal coagulation has been implicated in the pathogenesis of ischemic stroke, but how this association is mediated and whether it differs between ischemic stroke subtypes is unknown. We determined the shared genetic risk between 14 coagulation factors and ischemic stroke and its subtypes. Using genome-wide association study results for 14 coagulation factors from the population-based TwinsUK sample (N≈2000 for each factor), meta-analysis results from the METASTROKE consortium ischemic stroke genome-wide association study (12 389 cases, 62 004 controls), and genotype data for 9520 individuals from the WTCCC2 ischemic stroke study (3548 cases, 5972 controls-the largest METASTROKE subsample), we explored shared genetic risk for coagulation and stroke. We performed three analyses: (1) a test for excess concordance (or discordance) in single nucleotide polymorphism effect direction across coagulation and stroke, (2) an estimation of the joint effect of multiple coagulation-associated single nucleotide polymorphisms in stroke, and (3) an evaluation of common genetic risk between coagulation and stroke. One coagulation factor, factor XIII subunit B (FXIIIB), showed consistent effects in the concordance analysis, the estimation of polygenic risk, and the validation with genotype data, with associations specific to the cardioembolic stroke subtype. Effect directions for FXIIIB-associated single nucleotide polymorphisms were significantly discordant with cardioembolic disease (smallest P=5.7×10(-04)); the joint effect of FXIIIB-associated single nucleotide polymorphisms was significantly predictive of ischemic stroke (smallest P=1.8×10(-04)) and the cardioembolic subtype (smallest P=1.7×10(-04)). We found substantial negative genetic covariation between FXIIIB and ischemic stroke (rG=-0.71, P=0.01) and the cardioembolic subtype (rG=-0.80, P=0.03). Genetic markers associated with low FXIIIB levels increase risk of ischemic stroke cardioembolic subtype. © 2015 The Authors.

  9. Accounting for unknown foster dams in the genetic evaluation of embryo transfer progeny.

    PubMed

    Suárez, M J; Munilla, S; Cantet, R J C

    2015-02-01

    Animals born by embryo transfer (ET) are usually not included in the genetic evaluation of beef cattle for preweaning growth if the recipient dam is unknown. This is primarily to avoid potential bias in the estimation of the unknown age of dam. We present a method that allows including records of calves with unknown age of dam. Assumptions are as follows: (i) foster cows belong to the same breed being evaluated, (ii) there is no correlation between the breeding value (BV) of the calf and the maternal BV of the recipient cow, and (iii) cows of all ages are used as recipients. We examine the issue of bias for the fixed level of unknown age of dam (AOD) and propose an estimator of the effect based on classical measurement error theory (MEM) and a Bayesian approach. Using stochastic simulation under random mating or selection, the MEM estimating equations were compared with BLUP in two situations as follows: (i) full information (FI); (ii) missing AOD information on some dams. Predictions of breeding value (PBV) from the FI situation had the smallest empirical average bias followed by PBV obtained without taking measurement error into account. In turn, MEM displayed the highest bias, although the differences were small. On the other hand, MEM showed the smallest MSEP, for either random mating or selection, followed by FI, whereas ignoring measurement error produced the largest MSEP. As a consequence from the smallest MSEP with a relatively small bias, empirical accuracies of PBV were larger for MEM than those for full information, which in turn showed larger accuracies than the situation ignoring measurement error. It is concluded that MEM equations are a useful alternative for analysing weaning weight data when recipient cows are unknown, as it mitigates the effects of bias in AOD by decreasing MSEP. © 2014 Blackwell Verlag GmbH.

  10. Color stability of pigmented maxillofacial silicone elastomer: effects of nano-oxides as opacifiers.

    PubMed

    Han, Ying; Zhao, Yimin; Xie, Chao; Powers, John M; Kiat-amnuay, Sudarat

    2010-01-01

    This study evaluated the effects of nano-oxides on the color stability of pigmented silicone A-2186 maxillofacial prosthetic elastomers before and after artificial aging. Each of three widely used UV-shielding nano-sized particle oxides (TiO(2), ZnO, CeO(2)), based on recent survey of the industry at 1%, 2%, 2.5% concentrations were combined with each of five intrinsic silicone pigment types (no pigments, red, yellow, blue, and a mixture of the three pigments). Silicone A-2186 without nano-oxides or pigments served as control, for a total of 46 experimental groups of elastomers. In each group of the study, all specimens were aged in an artificial aging chamber for an energy exposure of 450kJ/m(2). CIE L*a*b* values were measured by a spectrophotometer. The 50:50% perceptibility (ΔE*=1.1) and acceptability threshold (ΔE*=3.0) were used in interpretation of recorded color differences. Color differences after aging were subjected to three-way analysis of variance. Means were compared by Fisher's PLSD intervals at the 0.05 level of significance. Yellow pigments mixed with all three nano-oxides at all intervals increased ΔE* values significantly from 3.7 up to 8.4. When mixed pigment groups were considered, TiO(2) at 2%, and 2.5% exhibited the smallest color changes, followed by ZnO and CeO(2), respectively (p<0.001). At 1%, CeO(2) exhibited the smallest color changes, followed by TiO(2) and ZnO, respectively (p<0.001). The smallest color differences, observed for nano-oxides groups, were recorded for CeO(2) at 1%, and TiO(2) at 2% and 2.5%. When the nano-oxides were tested at all concentrations, CeO(2) groups overall had the most color changes, and TiO(2) groups had the least. All ΔE* values of the mixed pigment groups were below the 50:50% acceptability threshold (ΔE*=1.2-2.3, below 3.0) except 2% CeO(2) (ΔE*=4.2). 1% nano-CeO(2) and 2% and 2.5% nano-TiO(2) used as opacifiers for silicone A-2186 maxillofacial prostheses with mixed pigments exhibited the least color changes when subjected to artificial aging at 450kJ/m(2). Yellow silicone pigment mixed with all three nano-oxides significantly affected color stability of A-2186 silicone elastomer. Copyright © 2010 Elsevier Ltd. All rights reserved.

  11. Are tidal volume measurements in neonatal pressure-controlled ventilation accurate?

    PubMed

    Chow, Lily C; Vanderhal, Andre; Raber, Jorge; Sola, Augusto

    2002-09-01

    Bedside pulmonary mechanics monitors (PMM) have become useful in ventilatory management in neonates. These monitors are used more frequently due to recent improvements in data-processing capabilities. PMM devices are often part of the ventilator or are separate units. The accuracy and reliability of these systems have not been carefully evaluated. We compared a single ventilatory parameter, tidal volume (V(t)), as measured by several systems. We looked at two freestanding PMMs: the Ventrak Respiratory Monitoring System (Novametrix, Wallingford, CT) and the Bicore CP-100 Neonatal Pulmonary Monitor (Allied Health Care Products, Riverside, CA), and three ventilators with built-in PMM: the VIP Bird Ventilator (Bird Products Corp., Palm Springs, CA), Siemens Servo 300A (Siemens-Elema AB, Solna, Sweden), and Drager Babylog 8000 (Drager, Inc., Chantilly, VA). A calibrated syringe (Hans Rudolph, Inc., Kansas City, MO) was used to deliver tidal volumes of 4, 10, and 20 mL to each ventilator system coupled with a freestanding PMM. After achieving steady state, six consecutive V(t) readings were taken simultaneously from the freestanding PMM and each ventilator. In a second portion of the bench study, we used pressure-control ventilation and measured exhaled tidal volume (V(te)) while ventilating a Bear Test Lung with the same three ventilators. We adjusted peak inspiratory pressure (PIP) under controlled conditions to achieve the three different targeted tidal volumes on the paired freestanding PMM. Again, six V(te) measurements were recorded for each tidal volume. Means and standard deviations were calculated.The percentage difference in measurement of V(t) delivered by calibrated syringe varied greatly, with the greatest discrepancy seen in the smallest tidal volumes, by up to 28%. In pressure control mode, V(te) as measured by the Siemens was significantly overestimated by 20-95%, with the biggest discrepancy at the smallest V(te), particularly when paired with the Bicore PMM. V(te), as measured by the VIP Bird and Drager paired with the Ventrak PMM, had a tendency to underestimate V(t) by up to 25% at the smallest V(te). However, when paired with the Bicore PMM, these same two ventilators read over target by up to 18%. Under controlled laboratory conditions, we demonstrated that true delivered V(te), as measured by the three ventilators and two freestanding PMM, differed markedly. In general, decreasing dynamic compliance of the tubing was not associated with greater inaccuracy in V(te) measurements. Copyright 2002 Wiley-Liss, Inc.

  12. Influence of imaging resolution on color fidelity in digital archiving.

    PubMed

    Zhang, Pengchang; Toque, Jay Arre; Ide-Ektessabi, Ari

    2015-11-01

    Color fidelity is of paramount importance in digital archiving. In this paper, the relationship between color fidelity and imaging resolution was explored by calculating the color difference of an IT8.7/2 color chart with a CIELAB color difference formula for scanning and simulation images. Microscopic spatial sampling was used in selecting the image pixels for the calculations to highlight the loss of color information. A ratio, called the relative imaging definition (RID), was defined to express the correlation between image resolution and color fidelity. The results show that in order for color differences to remain unrecognizable, the imaging resolution should be at least 10 times higher than the physical dimension of the smallest feature in the object being studied.

  13. Characterising the variations in ethnic skin colours: a new calibrated data base for human skin.

    PubMed

    Xiao, K; Yates, J M; Zardawi, F; Sueeprasan, S; Liao, N; Gill, L; Li, C; Wuerger, S

    2017-02-01

    Accurate skin colour measurements are important for numerous medical applications including the diagnosis and treatment of cutaneous disorders and the provision of maxillofacial soft tissue prostheses. In this study, we obtained accurate skin colour measurements from four different ethnic groups (Caucasian, Chinese, Kurdish, Thai) and at four different body locations (Forehead, cheek, inner arm, back of hand) with a view of establishing a new skin colour database for medical and cosmetic applications. Skin colours are measured using a spectrophotometer and converted to a device-independent standard colour appearance space (CIELAB) where skin colour is expressed as values along the three dimensions: Lightness L*, Redness a* and Yellowness b*. Skin colour differences and variation are then evaluated as a function of ethnicity and body location. We report three main results: (1) When plotted in a standard colour appearance space (CIELAB), skin colour distributions for the four ethnic groups overlap significantly, although there are systematic mean differences. Between ethnicities, the most significant skin colour differences occur along the yellowness dimension, with Thai skin exhibiting the highest yellowness (b*) value and Caucasian skin the lowest value. Facial redness (a*) is invariant across the four ethnic groups. (2) Between different body locations, there are significant variations in redness (a*), with the forehead showing the highest redness value and the inner arm the lowest. (3) The colour gamut is smallest in the Chinese sample and largest in the Caucasian sample, with the Chinese gamut lying entirely the Caucasian gamut. Similarly, the largest variability in skin tones is found in the Caucasian group, and the smallest in the Chinese group. Broadly speaking, skin colour variation can be explained by two main factors: individual differences in lightness and yellowness are mostly due to ethnicity, whereas differences in redness are primarily due to different body locations. Variations in lightness are more idiosyncratic probably reflecting the large influence of environmental factors such as exposure to sun. © 2016 The Authors. Skin Research and Technology Published by John Wiley & Sons Ltd.

  14. Educational differences in disability-free life expectancy: a comparative study of long-standing activity limitation in eight European countries.

    PubMed

    Mäki, Netta; Martikainen, Pekka; Eikemo, Terje; Menvielle, Gwenn; Lundberg, Olle; Ostergren, Olof; Jasilionis, Domantas; Mackenbach, Johan P

    2013-10-01

    Healthy life expectancy is a composite measure of length and quality of life and an important indicator of health in aging populations. There are few cross-country comparisons of socioeconomic differences in healthy life expectancy. Most of the existing comparisons focus on Western Europe and the United States, often relying on older data. To address these deficiencies, we estimated educational differences in disability-free life expectancy for eight countries from all parts of Europe in the early 2000s. Long-standing severe disability was measured as a Global Activity Limitation Indicator (GALI) derived from the European Union Statistics on Income and Living Conditions (EU-SILC) survey. Census-linked mortality data were collected by a recent project comparing health inequalities between European countries (the EURO-GBD-SE project). We calculated sex-specific educational differences in disability-free life expectancy between the ages of 30 and 79 years using the Sullivan method. The lowest disability-free life expectancy was found among Lithuanian men and women (33.1 and 39.1 years, respectively) and the highest among Italian men and women (42.8 and 44.4 years, respectively). Life expectancy and disability-free life expectancy were directly related to the level of education, but the educational differences were much greater in the latter in all countries. The difference in the disability-free life expectancy between those with a primary or lower secondary education and those with a tertiary education was over 10 years for males in Lithuania and approximately 7 years for males in Austria, Finland and France, as well as for females in Lithuania. The difference was smallest in Italy (4 and 2 years among men and women, respectively). Highly educated Europeans can expect to live longer and spend more years in better health than those with lower education. The size of the educational difference in disability-free life expectancy varies significantly between countries. The smallest and largest differences appear to be in Southern Europe and in Eastern and Northern Europe, respectively. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Photographer : JPL Europa , the smallest of the Galilean satellites, or Moons , of Jupiter , is seen

    NASA Technical Reports Server (NTRS)

    1979-01-01

    Photographer : JPL Europa , the smallest of the Galilean satellites, or Moons , of Jupiter , is seen here as taken by Voyager 1. Range : 2 million km (1.2 million miles) is centered at about the 300 degree Meridian. The bright areas are probably ice deposits, while the dark may be rocky surface or areas of more patchy ice distribution. Most unusual features are systems of linear structures crossing the surface in various directions. Of these, some of which are over 1000 km. long , & 2 or 3 hundred km. wide, may be faults which have disrupted the surface.

  16. Cause-specific sickness absence trends by occupational class and industrial sector in the context of recent labour market changes: a Finnish panel data study

    PubMed Central

    Leinonen, Taina; Viikari-Juntura, Eira; Husgafvel-Pursiainen, Kirsti; Solovieva, Svetlana

    2018-01-01

    Objectives We aimed to provide previously unestablished information on population-based differences in cause-specific sickness absence trends between occupational classes and further between four large industrial sectors within the different occupational classes while controlling for other socioeconomic factors and employment patterns. We focused on the period 2005–2013, during which the labour market underwent large economic and structural changes in many countries. Design Register-based panel data study. Setting Large representative datasets on Finnish wage earners aged 25–59 years. Outcome measure Annual risk of sickness absence (>10 working days) based on repeated logistic regression. Results Between 2005 and 2013, the proportion of employees with sickness absence decreased. Occupational class differences in sickness absence trends varied by disease group. Overall, the decrease in absences was smallest among lower non-manual employees. Sickness absence levels were highest in the health and social work sector and in the manufacturing sector within the non-manual and manual classes, respectively. Absences due to musculoskeletal diseases decreased temporarily during the peak of the economic recession in 2009, particularly in the manufacturing sector within the manual class. The decrease in absences due to musculoskeletal diseases was smallest in the trade sector within the lower occupational classes. Overall, education, income and employment patterns partly explained the differences in the absence levels, but not in the trends. Conclusions We found a complex interplay between the associations of occupational class and industrial sector with sickness absence trends. During the economic recession, absences due to musculoskeletal diseases decreased temporarily in a segment of wage earners who were known to have been hit hard by the recession. However, the trend differences were not explained by the measured structural changes in the characteristics of the study population. Both occupational class and industrial sector should be taken into account when tackling problems of work disability. PMID:29627810

  17. Technical Note: Statistical dependences between channels in radiochromic film readings. Implications in multichannel dosimetry.

    PubMed

    González-López, Antonio; Vera-Sánchez, Juan Antonio; Ruiz-Morales, Carmen

    2016-05-01

    This note studies the statistical relationships between color channels in radiochromic film readings with flatbed scanners. The same relationships are studied for noise. Finally, their implications for multichannel film dosimetry are discussed. Radiochromic films exposed to wedged fields of 6 MV energy were read in a flatbed scanner. The joint histograms of pairs of color channels were used to obtain the joint and conditional probability density functions between channels. Then, the conditional expectations and variances of one channel given another channel were obtained. Noise was extracted from film readings by means of a multiresolution analysis. Two different dose ranges were analyzed, the first one ranging from 112 to 473 cGy and the second one from 52 to 1290 cGy. For the smallest dose range, the conditional expectations of one channel given another channel can be approximated by linear functions, while the conditional variances are fairly constant. The slopes of the linear relationships between channels can be used to simplify the expression that estimates the dose by means of the multichannel method. The slopes of the linear relationships between each channel and the red one can also be interpreted as weights in the final contribution to dose estimation. However, for the largest dose range, the conditional expectations of one channel given another channel are no longer linear functions. Finally, noises in different channels were found to correlate weakly. Signals present in different channels of radiochromic film readings show a strong statistical dependence. By contrast, noise correlates weakly between channels. For the smallest dose range analyzed, the linear behavior between the conditional expectation of one channel given another channel can be used to simplify calculations in multichannel film dosimetry.

  18. An Experimental Investigation of Transverse Tension Fatigue Characterization of IM6/3501-6 Composite Materials Using a Three-Point Bend Test

    NASA Technical Reports Server (NTRS)

    Peck, Ann W.

    1998-01-01

    As composites are introduced into more complex structures with out-of-plane loadings, a better understanding is needed of the out-of-plane, matrix-dominated failure mechanisms. This work investigates the transverse tension fatigue characteristics of IM6/3501 composite materials. To test the 90 degree laminae, a three-point bend test was chosen, potentially minimizing handling and gripping issues associated with tension tests. A finite element analysis was performed of a particular specimen configuration to investigate the influence of specimen size on the stress distribution for a three-point bend test. Static testing of 50 specimens of 9 different sized configurations produced a mean transverse tensile strength of 61.3 Mpa (8.0 ksi). The smallest configuration (10.2 mm wide, Span-to-thickness ratio of 3) consistently exhibited transverse tensile failures. A volume scale effect was difficult to discern due to the large scatter of the data. Static testing of 10 different specimens taken from a second panel produced a mean transverse tensile strength of 82.7 Mpa (12.0 ksi). Weibull parameterization of the data was possible, but due to variability in raw material and/or manufacturing, more replicates are needed for greater confidence. Three-point flex fatigue testing of the smallest configuration was performed on 59 specimens at various levels of the mean static transverse tensile strength using an R ratio of 0.1 and a frequency of 20 Hz. A great deal of scatter was seen in the data. The majority of specimens failed near the center loading roller. To determine whether the scatter in the fatigue data is due to variability in raw material and/or the manufacturing process, additional testing should be performed on panels manufactured from different sources.

  19. Technical Note: Statistical dependences between channels in radiochromic film readings. Implications in multichannel dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    González-López, Antonio, E-mail: antonio.gonzalez7@carm.es; Vera-Sánchez, Juan Antonio; Ruiz-Morales, Carmen

    Purpose: This note studies the statistical relationships between color channels in radiochromic film readings with flatbed scanners. The same relationships are studied for noise. Finally, their implications for multichannel film dosimetry are discussed. Methods: Radiochromic films exposed to wedged fields of 6 MV energy were read in a flatbed scanner. The joint histograms of pairs of color channels were used to obtain the joint and conditional probability density functions between channels. Then, the conditional expectations and variances of one channel given another channel were obtained. Noise was extracted from film readings by means of a multiresolution analysis. Two different dosemore » ranges were analyzed, the first one ranging from 112 to 473 cGy and the second one from 52 to 1290 cGy. Results: For the smallest dose range, the conditional expectations of one channel given another channel can be approximated by linear functions, while the conditional variances are fairly constant. The slopes of the linear relationships between channels can be used to simplify the expression that estimates the dose by means of the multichannel method. The slopes of the linear relationships between each channel and the red one can also be interpreted as weights in the final contribution to dose estimation. However, for the largest dose range, the conditional expectations of one channel given another channel are no longer linear functions. Finally, noises in different channels were found to correlate weakly. Conclusions: Signals present in different channels of radiochromic film readings show a strong statistical dependence. By contrast, noise correlates weakly between channels. For the smallest dose range analyzed, the linear behavior between the conditional expectation of one channel given another channel can be used to simplify calculations in multichannel film dosimetry.« less

  20. AAVSO Solar Observers Worldwide

    NASA Astrophysics Data System (ADS)

    Howe, R.

    2013-06-01

    (Abstract only) For visual solar observers there has been no biological change in the "detector" (human eye) - at century scales (eye + visual cortex) does not change much over time. Our capacity to "integrate" seeing distortions is not just simple averaging! The visual cortex plays an essential role, and until recently only the SDO-HMI (Solar Dynamics Observatory, Helioseismic and Magnetic Imager) has had the capacity to detect the smallest sunspots, called pores. Prior to this the eye was superior to photography and CCD. Imaged data are not directly comparable or substitutable to counts by eye, as the effects of sensor/optical resolution and seeing will have a different influence on the resulting sunspot counts for images when compared to the human eye. Also contributing to the complex task of counting sunspots is differentiating between a sunspot (which is usually defined as having a darker center (umbra) and lighter outer ring (penumbra)) and a pore, made even more complex by the conflicting definitions of the word "pore" in the solar context: "pore" can mean a small spot without penumbra or "pore" can mean a random intergranular blemish that is not a true sunspot. The overall agreement is that the smallest spot size is near 2,000 km or ~3 arc sec, (Loughhead, R. E. and Bray, R. J. 1961, Australian J. Phys., 14, 347). Sunspot size is dictated by granulation dynamics rather than spot size (cancellation of convective motion), and by the lifetime of the pore, which averages from 10 to 30 minutes. There is no specific aperture required for AAVSO observers contributing sunspot observations. However, the detection of the smallest spots is influenced by the resolution of the telescope. Two factors to consider are the theoretical optical resolution (unobstructed aperture), Rayleigh criterion: theta = 138 / D(mm), and Dawes criterion: theta = 116 / D(mm) (http://www.telescope-optics.net/telescope_resolution.htm). However, seeing is variable with time; daytime range will be similar for all low-altitude sites, within the range of 1.5 to 3 arc sec, (typically = 2 arc sec equivalent diameter D = 45-90 mm, the typical solar scope = 70 mm aperture). Where large apertures are more affected by size of turbulent eddies ~8-12 cm, small-aperture telescopes reduce these differences, i.e. large aperture is not always beneficial.

  1. Drought effect on weaning weight and efficiency relative to cow size in semiarid rangeland.

    PubMed

    Scasta, J D; Henderson, L; Smith, T

    2015-12-01

    Cow size has been suggested to be an important consideration for selecting cattle to match their production environment. Over the last several decades, the trend in genetic selection for maximum growth has led to gradual increases in beef cow size. An unrelated trend during this same period in the western United States has been an increase in temperature, drought frequency, and drought severity. Due to the potential influence of the increasing cow size trend on nutritional maintenance costs and production, we assessed the effect of cow size on weaning weight and efficiency in relation to drought on a semiarid high-elevation ranch in Wyoming. This study addresses a lack of empirical studies on the interaction between cow size and drought. We measured calf weaning weights of 80 Angus × Gelbvieh cows from 2011 to 2014 and assessed how drought affected weaning weights, efficiency (considered as calf weight relative to cow weight), intake requirements, and potential herd sizes relative to cow size. We stratified cows into 5 weight classes (453, 498, 544, 589, and 634 kg) as a proxy for cow size and adjusted weaning weights to a 210-d calf sex adjusted value. Cow size was a significant factor every year, with different cow sizes having advantages or disadvantages different years relative to weaning weight. However, efficiency for the smallest cows (453 kg) was always greater than efficiency for largest cows (634 kg; < 0.001). Efficiency for the smallest cows was greater in the driest year (0.41 ± 0.02) than efficiency of the largest cows in the wettest years (0.37 ± 0.01). The change in efficiency (ΔE) between wet and dry years was 0.18 for the smallest cow size and 0.02 for the largest cow size, and ΔE decreased as cow size increased. This is an indication of the ability of smaller cows to lower maintenance requirements in response to changes in the production environment but with optimal upside potential when conditions are favorable. These results indicate large cows (589 to 634 kg) do not maximize genetic potential in this production environment when conditions are optimum or provide any advantage over small or moderate size cows (453 to 544 kg) across the drought gradient.

  2. Biased random walks on Kleinberg's spatial networks

    NASA Astrophysics Data System (ADS)

    Pan, Gui-Jun; Niu, Rui-Wu

    2016-12-01

    We investigate the problem of the particle or message that travels as a biased random walk toward a target node in Kleinberg's spatial network which is built from a d-dimensional (d = 2) regular lattice improved by adding long-range shortcuts with probability P(rij) ∼rij-α, where rij is the lattice distance between sites i and j, and α is a variable exponent. Bias is represented as a probability p of the packet to travel at every hop toward the node which has the smallest Manhattan distance to the target node. We study the mean first passage time (MFPT) for different exponent α and the scaling of the MFPT with the size of the network L. We find that there exists a threshold probability pth ≈ 0.5, for p ≥pth the optimal transportation condition is obtained with an optimal transport exponent αop = d, while for 0 < p pth, and increases with L less than a power law and get close to logarithmical law for 0 < p

  3. Panchromatic SED modelling of spatially resolved galaxies

    NASA Astrophysics Data System (ADS)

    Smith, Daniel J. B.; Hayward, Christopher C.

    2018-05-01

    We test the efficacy of the energy-balance spectral energy distribution (SED) fitting code MAGPHYS for recovering the spatially resolved properties of a simulated isolated disc galaxy, for which it was not designed. We perform 226 950 MAGPHYS SED fits to regions between 0.2 and 25 kpc in size across the galaxy's disc, viewed from three different sight-lines, to probe how well MAGPHYS can recover key galaxy properties based on 21 bands of UV-far-infrared model photometry. MAGPHYS yields statistically acceptable fits to >99 per cent of the pixels within the r-band effective radius and between 59 and 77 percent of pixels within 20 kpc of the nucleus. MAGPHYS is able to recover the distribution of stellar mass, star formation rate (SFR), specific SFR, dust luminosity, dust mass, and V-band attenuation reasonably well, especially when the pixel size is ≳ 1 kpc, whereas non-standard outputs (stellar metallicity and mass-weighted age) are recovered less well. Accurate recovery is more challenging in the smallest sub-regions of the disc (pixel scale ≲ 1 kpc), where the energy balance criterion becomes increasingly incorrect. Estimating integrated galaxy properties by summing the recovered pixel values, the true integrated values of all parameters considered except metallicity and age are well recovered at all spatial resolutions, ranging from 0.2 kpc to integrating across the disc, albeit with some evidence for resolution-dependent biases. These results must be considered when attempting to analyse the structure of real galaxies with actual observational data, for which the `ground truth' is unknown.

  4. Reducing the cost of headache medication.

    PubMed

    Solomon, Glen D

    2009-06-01

    Although medication costs make up one of the smallest portions of the overall expense of headache care, it is the segment of expense that often impacts the patient most directly. The advent of triptans marked a major advance in migraine therapy, but their high cost has limited their widespread use. Four options can be considered as potential means to reduce the cost of triptans. These include compulsory licensing, exclusive contracting, over-the-counter -availability, and the introduction of generic triptans. Each method impacts the consumer, third-party payer, or pharmaceutical company in a different manner.

  5. Crystal structure of the Yersinia type III secretion protein YscE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Phan, Jason; Austin, Brian P.; Waugh, David S.

    2010-12-06

    The plague-causing bacterium Yersinia pestis utilizes a contact-dependent (type III) secretion system (T3SS) to transport virulence factors from the bacterial cytosol directly into the interior of mammalian cells where they interfere with signal transduction pathways that mediate phagocytosis and the inflammatory response. The type III secretion apparatus is composed of 20-25 different Yersinia secretion (Ysc) proteins. We report here the structure of YscE, the smallest Ysc protein, which is a dimer in solution. The probable mode of oligomerization is discussed.

  6. Studies toward the synthesis of linear triazole linked pseudo oligosaccharides and the use of ferrocene as analytical probe.

    PubMed

    Schmidt, Magnus S; Götz, Kathrin H; Koch, Wolfgang; Grimm, Tanja; Ringwald, Markus

    2016-04-29

    Three different building blocks have been synthesised and used for the synthesis of linear triazole linked pseudo oligosaccharides with copper(I)-catalysed cycloaddition (CuAAC). Ethynylferrocene has been used as analytical probe to improve the UV/Vis properties and HPLC methods have been used and optimised for the analysis of the pseudo oligosaccharides. The smallest ones have been isolated and characterised by analytical HPLC, NMR, ESI-MS and elemental analysis. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Resistance to rocuronium of rat diaphragm as compared with limb muscles.

    PubMed

    Huang, Lina; Yang, Meirong; Chen, Lianhua; Li, Shitong

    2014-12-01

    Skeletal muscles are composed of different muscle fiber types. We investigated the different potency to rocuronium among diaphragm (DIA), extensor digitorum longus (EDL), and soleus (SOL) in vitro as well as to investigate the differences of acetylcholine receptors (AChRs) among these three typical kinds of muscles. The isolated left hemidiaphragm nerve-muscle preparations, the EDL sciatic nerve-muscle preparations, and the SOL sciatic nerve-muscle preparations were established to evaluate the potency to rocuronium. Concentration-response curves were constructed and the values of IC50 were obtained. The density of AChRs at the end plate and the number of AChRs per unit fiber cross fiber area (CSA), AChR affinity for muscle relaxants were evaluated. The concentration-twitch tension curves of rocuronium were significantly different. The curves demonstrated a shift to the right of the DIA compared with the EDL and SOL (P < 0.01), whereas no significant difference was observed between EDL and SOL (P > 0.05). IC50 was significantly largest in DIA, second largest in SOL, and smallest in EDL (P < 0.05). The number of AChRs per unit fiber CSA was largest in DIA, second largest in EDL, and smallest in SOL (P < 0.01 or P < 0.05). The DIA showed the lowest affinity of the AChRs, whereas the SOL showed the highest affinity. The resistance to rocuronium of DIA compared with EDL and SOL was verified. The DIA was characterized by the largest number of AChRs per unit fiber CSA and the lowest affinity of the AChRs. Although compared with SOL, EDL was proved to have larger number of AChRs per unit fiber CSA and the lower affinity of the AChRs. These findings may be the mechanisms of different potency to rocuronium in DIA, EDL, and SOL. The results of the study could help to explain the relationship between different composition of muscle fibers and the potency to muscle relaxants. Extra caution should be taken in clinical practice when monitoring muscle relaxation in anesthetic management using different muscles. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. FAWKES Information Management for Space Situational Awareness

    NASA Astrophysics Data System (ADS)

    Spetka, S.; Ramseyer, G.; Tucker, S.

    2010-09-01

    Current space situational awareness assets can be fully utilized by managing their inputs and outputs in real time. Ideally, sensors are tasked to perform specific functions to maximize their effectiveness. Many sensors are capable of collecting more data than is needed for a particular purpose, leading to the potential to enhance a sensor’s utilization by allowing it to be re-tasked in real time when it is determined that sufficient data has been acquired to meet the first task’s requirements. In addition, understanding a situation involving fast-traveling objects in space may require inputs from more than one sensor, leading to a need for information sharing in real time. Observations that are not processed in real time may be archived to support forensic analysis for accidents and for long-term studies. Space Situational Awareness (SSA) requires an extremely robust distributed software platform to appropriately manage the collection and distribution for both real-time decision-making as well as for analysis. FAWKES is being developed as a Joint Space Operations Center (JSPOC) Mission System (JMS) compliant implementation of the AFRL Phoenix information management architecture. It implements a pub/sub/archive/query (PSAQ) approach to communications designed for high performance applications. FAWKES provides an easy to use, reliable interface for structuring parallel processing, and is particularly well suited to the requirements of SSA. In addition to supporting point-to-point communications, it offers an elegant and robust implementation of collective communications, to scatter, gather and reduce values. A query capability is also supported that enhances reliability. Archived messages can be queried to re-create a computation or to selectively retrieve previous publications. PSAQ processes express their role in a computation by subscribing to their inputs and by publishing their results. Sensors on the edge can subscribe to inputs by appropriately authorized users, allowing dynamic tasking capabilities. Previously, the publication of sensor data collected by mobile systems was demonstrated. Thumbnails of infrared imagery that were imaged in real time by an aircraft [1] were published over a grid. This airborne system subscribed to requests for and then published the requested detailed images. In another experiment a system employing video subscriptions [2] drove the analysis of live video streams, resulting in a published stream of processed video output. We are currently implementing an SSA system that uses FAWKES to deliver imagery from telescopes through a pipeline of processing steps that are performed on high performance computers. PSAQ facilitates the decomposition of a problem into components that can be distributed across processing assets from the smallest sensors in space to the largest high performance computing (HPC) centers, as well as the integration and distribution of the results, all in real time. FAWKES supports the real-time latency requirements demanded by all of these applications. It also enhances reliability by easily supporting redundant computation. This study shows how FAWKES/PSAQ is utilized in SSA applications, and presents performance results for latency and throughput that meet these needs.

  9. Zirconia-Polyurethane Aneurysm Clip.

    PubMed

    Cho, Won-Sang; Cho, Kyung-Il; Kim, Jeong Eun; Jang, Tae-Sik; Ha, Eun Jin; Kang, Hyun-Seung; Son, Young-Je; Choi, Seung Hong; Lee, Seunghyun; Kim, Chong-Chan; Sun, Jeong-Yun; Kim, Hyoun-Ee

    2018-03-27

    Susceptibility artifacts from metal clips in magnetic resonance (MR) imaging present an obstacle to evaluating the status of clipped aneurysms, parent arteries and adjacent brain parenchyma. We aimed to develop MR-compatible aneurysm clips. Considering the mechanical and biological properties, and MR compatibility of candidate materials, a prototype clip with a zirconia body and a polyurethane head spring (ZC, straight, 9-mm long) was developed. The closing forces, opening width of blades, and in vitro and in vivo artifact volumes in 3 tesla MR imaging were compared among the prototype and commercial metal clips such as a Yasargil ® clip (YC, curved type, 8.3-mm long) and a Sugita ® clip (SC, straight type, 10-mm long). An in vivo animal study was performed with a canine venous pouch aneurysm model. The closing forces (N) at 1 and 8 mm from the blade tip were 2.09 and 3.77 in YC, 1.85 and 3.04 in SC, and 2.05 and 4.60 in ZC. The maximum opening widths (mm) was 6.8, 9.0, and 3.0 in YC, SC, and ZC, respectively. The in vitro artifact volumes of YC, SC and ZC in time-of-flight MR imaging were 26.9, 29.7 and 1.9 times larger than the respective real volumes. The in vivo artifact volumes of YC, SC, and ZC were respectively 21.4, 29.4, and 2.6 times larger than real ones. ZC showed the smallest susceptibility artifacts and satisfactory closing forces. However, the narrow opening width of the blades was a weak point. Copyright © 2018. Published by Elsevier Inc.

  10. Small-strain measurement in bridge connections using the digital image correlation (DIC) technique

    NASA Astrophysics Data System (ADS)

    Desai, Niranjan

    2016-04-01

    Structural health monitoring (SHM) is emerging as a vital tool to help civil engineers improve the safety, maintainability, and reliability of critical structures and assists infrastructure owners with timely information for the continued safe and economic operation of their structure. SHM involves implementing a strategy that identifies and characterizes damage or undesirable performance in engineering structures. The goal of this research project was to determine the smallest strains measurable using standard digital image correlation (DIC) based SHM equipment. This practical investigation that had strong ties to the industry was motivated by damage observed in a real-world bridge, which was initially undetected. Its early detection would have led to reduced repair costs. To accomplish the aforementioned goal, tests were performed on a laboratory specimen that replicated a steel beam-to-column connection of the concerned bridge, involving progressively loading it in a manner in which it was loaded in the actual bridge, while simultaneously measuring the strains that developed in it using the aforementioned DIC-based equipment and software. Under the controlled conditions in the laboratory, the minimum resolution of the state-of-the-art system used in this investigation was determined. Due to the challenges faced in making these small-strain measurements even under highly controlled laboratory conditions, it was concluded that it is currently unrealistic to use the existing DIC technology in a real-world situation to measure strains as small as those that would need to be measured to detect the onset of damage in bridge connections. More work needs to be done in this area.

  11. Comparison between medial rectus pulley fixation and augmented recession in children with convergence excess and variable-angle infantile esotropia.

    PubMed

    Fouad, Heba M; Abdelhakim, Mohamad A; Awadein, Ahmed; Elhilali, Hala

    2016-10-01

    To compare the outcomes of medial rectus (MR) muscle pulley fixation and augmented recession in children with convergence excess esotropia and variable-angle infantile esotropia. This was a prospective randomized interventional study in which children with convergence excess esotropia or variable-angle infantile esotropia were randomly allocated to either augmented MR muscle recession (augmented group) or MR muscle pulley posterior fixation (pulley group). In convergence excess, the MR recession was based on the average of distance and near angles of deviation with distance correction in the augmented group, and on the distance angle of deviation in the pulley group. In variable-angle infantile esotropia, the MR recession was based on the average of the largest and smallest angles in the augmented group and on the smallest angle in the pulley group. Pre- and postoperative ductions, versions, pattern strabismus, smallest and largest angles of deviation, and angle disparity were analyzed. Surgery was performed on 60 patients: 30 underwent bilateral augmented MR recession, and 30 underwent bilateral MR recession with pulley fixation. The success rate was statistically significantly higher (P = 0.037) in the pulley group (70%) than in the augmented group (40%). The postoperative smallest and largest angles and the angle disparity were statistically significantly lower in the pulley group than the augmented group (P < 0.01). Medial rectus muscle pulley fixation is a useful surgical step for addressing marked variability of the angle in variable angle esotropia and convergence excess esotropia. Copyright © 2016 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  12. Capacitor-Chain Successive-Approximation ADC

    NASA Technical Reports Server (NTRS)

    Cunningham, Thomas

    2003-01-01

    A proposed successive-approximation analog-to-digital converter (ADC) would contain a capacitively terminated chain of identical capacitor cells. Like a conventional successive-approximation ADC containing a bank of binary-scaled capacitors, the proposed ADC would store an input voltage on a sample-and-hold capacitor and would digitize the stored input voltage by finding the closest match between this voltage and a capacitively generated sum of binary fractions of a reference voltage (Vref). However, the proposed capacitor-chain ADC would offer two major advantages over a conventional binary-scaled-capacitor ADC: (1) In a conventional ADC that digitizes to n bits, the largest capacitor (representing the most significant bit) must have 2(exp n-1) times as much capacitance, and hence, approximately 2(exp n-1) times as much area as does the smallest capacitor (representing the least significant bit), so that the total capacitor area must be 2(exp n) times that of the smallest capacitor. In the proposed capacitor-chain ADC, there would be three capacitors per cell, each approximately equal to the smallest capacitor in the conventional ADC, and there would be one cell per bit. Therefore, the total capacitor area would be only about 3(exp n) times that of the smallest capacitor. The net result would be that the proposed ADC could be considerably smaller than the conventional ADC. (2) Because of edge effects, parasitic capacitances, and manufacturing tolerances, it is difficult to make capacitor banks in which the values of capacitance are scaled by powers of 2 to the required precision. In contrast, because all the capacitors in the proposed ADC would be identical, the problem of precise binary scaling would not arise.

  13. Almost conserved operators in nearly many-body localized systems

    NASA Astrophysics Data System (ADS)

    Pancotti, Nicola; Knap, Michael; Huse, David A.; Cirac, J. Ignacio; Bañuls, Mari Carmen

    2018-03-01

    We construct almost conserved local operators, that possess a minimal commutator with the Hamiltonian of the system, near the many-body localization transition of a one-dimensional disordered spin chain. We collect statistics of these slow operators for different support sizes and disorder strengths, both using exact diagonalization and tensor networks. Our results show that the scaling of the average of the smallest commutators with the support size is sensitive to Griffiths effects in the thermal phase and the onset of many-body localization. Furthermore, we demonstrate that the probability distributions of the commutators can be analyzed using extreme value theory and that their tails reveal the difference between diffusive and subdiffusive dynamics in the thermal phase.

  14. The mitochondrial genome of the ethanol-metabolizing, wine cellar mold Zasmidium cellare is the smallest for a filamentous ascomycete.

    PubMed

    Goodwin, Stephen B; McCorison, Cassandra B; Cavaletto, Jessica R; Culley, David E; LaButti, Kurt; Baker, Scott E; Grigoriev, Igor V

    2016-08-01

    Fungi in the class Dothideomycetes often live in extreme environments or have unusual physiology. One of these, the wine cellar mold Zasmidium cellare, produces thick curtains of mycelia in cellars with high humidity, and its ability to metabolize volatile organic compounds is thought to improve air quality. Whether these abilities have affected its mitochondrial genome is not known. To fill this gap, the circular-mapping mitochondrial genome of Z. cellare was sequenced and, at only 23 743 bp, is the smallest reported for a filamentous fungus. Genes were encoded on both strands with a single change of direction, different from most other fungi but consistent with the Dothideomycetes. Other than its small size, the only unusual feature of the Z. cellare mitochondrial genome was two copies of a 110-bp sequence that were duplicated, inverted and separated by approximately 1 kb. This inverted-repeat sequence confused the assembly program but appears to have no functional significance. The small size of the Z. cellare mitochondrial genome was due to slightly smaller genes, lack of introns and non-essential genes, reduced intergenic spacers and very few ORFs relative to other fungi rather than a loss of essential genes. Whether this reduction facilitates its unusual biology remains unknown. Published by Elsevier Ltd.

  15. Organization of the nucleoli of soybean root meristematic cells at different states of their activity.

    PubMed

    Stepiński, Dariusz

    2010-06-01

    Internal organization of a nucleolus changes along with rRNA transcriptional activity. These changes mainly concern qualitative and quantitative alternations of three main nucleolar components: fibrillar centres (FC), dense fibrillar component (DFC) and granular component (GC). In the present work quantitative measurements of the number and sizes of FCs and DFCs in nucleoli of root meristematic cells of soybean seedlings grown at (1) chilling conditions that reduce transcriptional activity of soybean nucleoli (temp. of 10 degrees C) and at (2) conditions that increase this activity (recovery at optimal temp. of 25 degrees C after previous chilling), even more than (3) the control, have been carried out. Morphometric measurements showed that the highest number of FCs and DFCs was in the most active nucleoli, while the smallest number - in those with the lowest activity. The average size of an individual FC was similar in all nucleoli regardless of their transcriptional activity, that of the individual DFC varied, being bigger in the nucleoli of the chilled plants and smallest in those of the recovered plants. The numbers of FCs and DFCs seem to be indicators of transcriptional activity of plant nucleoli - the higher number of FCs and DFCs the more active nucleoli. Copyright 2009 Elsevier Ltd. All rights reserved.

  16. Extending semi-numeric reionization models to the first stars and galaxies

    NASA Astrophysics Data System (ADS)

    Koh, Daegene; Wise, John H.

    2018-03-01

    Semi-numeric methods have made it possible to efficiently model the epoch of reionization (EoR). While most implementations involve a reduction to a simple three-parameter model, we introduce a new mass-dependent ionizing efficiency parameter that folds in physical parameters that are constrained by the latest numerical simulations. This new parametrization enables the effective modelling of a broad range of host halo masses containing ionizing sources, extending from the smallest Population III host haloes with M ˜ 106 M⊙, which are often ignored, to the rarest cosmic peaks with M ˜ 1012 M⊙ during EoR. We compare the resulting ionizing histories with a typical three-parameter model and also compare with the latest constraints from the Planck mission. Our model results in an optical depth due to Thomson scattering, τe = 0.057, that is consistent with Planck. The largest difference in our model is shown in the resulting bubble size distributions that peak at lower characteristic sizes and are broadened. We also consider the uncertainties of the various physical parameters, and comparing the resulting ionizing histories broadly disfavours a small contribution from galaxies. The smallest haloes cease a meaningful contribution to the ionizing photon budget after z = 10, implying that they play a role in determining the start of EoR and little else.

  17. Morphometric Parameters of Pyramidal Cells in CA1-CA4 Fields in the Hippocampus of Arctic Fox (Vulpes lagopus).

    PubMed

    Łuszczewska-Sierakowska, Iwona; Wawrzyniak-Gacek, Agata; Guz, Tomasz; Tatara, Marcin R; Charuta, Anna

    2015-01-01

    The aim of the study was a quantitative examination of neurons of hippocampal subfields (CA1-CA4) in mature male Arctic fox (Vulpes lagopus; syn. Alopex lagopus). The preparations were dyed using cresyl violet. Histological preparations were used to morphometricaly analyze the neurons of hippocampus. This analysis included the following parameters: average size of cells in μm, periphery of cells in μm, average cell area in μm2, percentage of cells in area and size of the largest and smallest cells in μm in CA1-CA4 fields. Morphometric observations show that the cells involved in hippocampal formation in polar fox in all layers CA1 -CA4 differ in size, shape, cell area and nucleus area. The size of the cell area in CA3 is the largest and fluctuates around 249.4 μm2, whereas in CA2 the cell area is 184.1 μm2. The cells of the CA2 field are densely arranged, pyramidal and contain a small amount of cytoplasm; their size fluctuates. Cells of CA2 and CA4 had the largest diameter of about 23.6 μm, whereas cells of the CA3 field had the smallest diameter of about 8.3 μm.

  18. Habituation analysis of chirp vs. tone evoked auditory late responses.

    PubMed

    Kern, Kevin; Royter, Vladislav; Corona-Strauss, Farah I; Mariam, Mai; Strauss, Daniel J

    2010-01-01

    We have recently shown that tone evoked auditory late responses are able to proof that habituation is occurring [1], [2]. The sweep to sweep analysis using time scale coherence method from [1] is used. Where clear results using tone evoked ALRs were obtained. Now it is of interest how does the results behave using chirp evoked ALRs compared to tone evoked ALRs so that basilar membrane dispersion is compensated. We presented three different tone bursts and three different band limited chirps to 10 subjects using two different loudness levels which the subjects determined themselves before as medium and uncomfortably loud. The 3 chirps are band limited within 3 different ranges, the chirp with the lowest center frequency has the smallest range (according to octave-band). Chirps and tone bursts are using the same center frequencies.

  19. Experimental performance of a 13.65-centimeter-tip-diameter tandem-bladed sweptback centrifugal compressor designed for a pressure ratio of 6

    NASA Technical Reports Server (NTRS)

    Klassen, H. A.; Wood, J. R.; Schumann, L. F.

    1977-01-01

    A 13.65 cm tip diameter backswept centrifugal impeller having a tandem inducer and a design mass flow rate of 0.907 kg/sec was experimentally investigated to establish stage and impeller characteristics. Tests were conducted with both a cascade diffuser and a vaneless diffuser. A pressure ratio of 5.9 was obtained near surge for the smallest clearance tested. Flow range at design speed was 6.3 percent for the smallest clearance test. Impeller exit to shroud axial clearance at design speed was varied to determine the effect on stage and impeller performance.

  20. Hierarchical formation of dark matter halos and the free streaming scale

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ishiyama, Tomoaki, E-mail: ishiyama@ccs.tsukuba.ac.jp

    2014-06-10

    The smallest dark matter halos are formed first in the early universe. According to recent studies, the central density cusp is much steeper in these halos than in larger halos and scales as ρ∝r {sup –(1.5-1.3)}. We present the results of very large cosmological N-body simulations of the hierarchical formation and evolution of halos over a wide mass range, beginning from the formation of the smallest halos. We confirmed early studies that the inner density cusps are steeper in halos at the free streaming scale. The cusp slope gradually becomes shallower as the halo mass increases. The slope of halosmore » 50 times more massive than the smallest halo is approximately –1.3. No strong correlation exists between the inner slope and the collapse epoch. The cusp slope of halos above the free streaming scale seems to be reduced primarily due to major merger processes. The concentration, estimated at the present universe, is predicted to be 60-70, consistent with theoretical models and earlier simulations, and ruling out simple power law mass-concentration relations. Microhalos could still exist in the present universe with the same steep density profiles.« less

  1. Structures of cage, prism, and book isomers of water hexamer from broadband rotational spectroscopy.

    PubMed

    Pérez, Cristóbal; Muckle, Matt T; Zaleski, Daniel P; Seifert, Nathan A; Temelso, Berhane; Shields, George C; Kisiel, Zbigniew; Pate, Brooks H

    2012-05-18

    Theory predicts the water hexamer to be the smallest water cluster with a three-dimensional hydrogen-bonding network as its minimum energy structure. There are several possible low-energy isomers, and calculations with different methods and basis sets assign them different relative stabilities. Previous experimental work has provided evidence for the cage, book, and cyclic isomers, but no experiment has identified multiple coexisting structures. Here, we report that broadband rotational spectroscopy in a pulsed supersonic expansion unambiguously identifies all three isomers; we determined their oxygen framework structures by means of oxygen-18-substituted water (H(2)(18)O). Relative isomer populations at different expansion conditions establish that the cage isomer is the minimum energy structure. Rotational spectra consistent with predicted heptamer and nonamer structures have also been identified.

  2. Detection-dependent kinetics as a probe of folding landscape microstructure.

    PubMed

    Yang, Wei Yuan; Gruebele, Martin

    2004-06-30

    The folding landscapes of polypeptides and proteins exhibit a hierarchy of local minima. The causes range from proline isomerization all the way down to microstructure in the free energy caused by residual frustration inherent in even the best 20 amino acid design. The corresponding time scales range from hours to submicroseconds. The smallest microstructures are difficult to detect. We have measured the folding/unfolding kinetics of the engineered trpzip2 peptide at different tryptophan fluorescence wavelengths, each yielding a different rate. Wavelength-dependent folding kinetics on 0.1-2 mus time scales show that different microstructures with a range of solvent exposure and local dynamics are populated. We estimate a lower limit for the roughness of the free energy surface based on the range of rates observed.

  3. Myonuclear domain size and myosin isoform expression in muscle fibres from mammals representing a 100,000-fold difference in body size.

    PubMed

    Liu, Jing-Xia; Höglund, Anna-Stina; Karlsson, Patrick; Lindblad, Joakim; Qaisar, Rizwan; Aare, Sudhakar; Bengtsson, Ewert; Larsson, Lars

    2009-01-01

    This comparative study of myonuclear domain (MND) size in mammalian species representing a 100,000-fold difference in body mass, ranging from 25 g to 2500 kg, was undertaken to improve our understanding of myonuclear organization in skeletal muscle fibres. Myonuclear domain size was calculated from three-dimensional reconstructions in a total of 235 single muscle fibre segments at a fixed sarcomere length. Irrespective of species, the largest MND size was observed in muscle fibres expressing fast myosin heavy chain (MyHC) isoforms, but in the two smallest mammalian species studied (mouse and rat), MND size was not larger in the fast-twitch fibres expressing the IIA MyHC isofom than in the slow-twitch type I fibres. In the larger mammals, the type I fibres always had the smallest average MND size, but contrary to mouse and rat muscles, type IIA fibres had lower mitochondrial enzyme activities than type I fibres. Myonuclear domain size was highly dependent on body mass in the two muscle fibre types expressed in all species, i.e. types I and IIA. Myonuclear domain size increased in muscle fibres expressing both the beta/slow (type I; r = 0.84, P < 0.001) and the fast IIA MyHC isoform (r = 0.90; P < 0.001). Thus, MND size scales with body size and is highly dependent on muscle fibre type, independent of species. However, myosin isoform expression is not the sole protein determining MND size, and other protein systems, such as mitochondrial proteins, may be equally or more important determinants of MND size.

  4. Species and Size Composition of Seahorses (Genus Hippocampus, Family Syngnathidae) in the Coastal Waters and Local Market of Kota Kinabalu, Sabah, Malaysia

    PubMed Central

    Shapawi, Rossita; Anyie, Adrian Leslie; Hussien, Muhammad Ali Syed; Zuldin, Wahidatul Husna

    2015-01-01

    Seahorse diversity (genus Hippocampus, Family Syngnathidae), species identification, size composition and sexual dimorphism were studied from November 2012 to March 2013 in selected coastal waters around Kota Kinabalu, Sabah and the local market trade. Six species of seahorses were identified in the study: (1) Hippocampus barbouri, (2) Hippocampus comes, (3) Hippocampus kelloggi, (4) Hippocampus kuda, (5) Hippocampus spinosissimus and (6) Hippocampus trimaculatus. All six species were sold at the local market, and the dried seahorses were obtained mainly by local fishermen using trawl by-catch method and traded as traditional medicine, souvenirs and other uses. Four species were identified by direct samplings in various different habitats of Kota Kinabalu coastal waters: (1) H. barbouri, (2) H. comes, (3) H. kuda, and (4) H. spinosissimus. Based on the results, H. comes was the largest in size among the four fresh/live species found (mean standard length [SL]: 148.25±1.26 mm), whereas H. barbouri was the smallest species (mean SL: 129±7.81 mm). For the dried samples, H. kelloggi was the largest (mean SL: 245.25±14.55 mm) and H. barbouri was the smallest (mean SL: 127.21±10.01 mm). No significant difference (p>0.05) was observed between the lengths of males and females in every seahorse species, and there was no sexual size dimorphism in any of the species. The findings from the study are significant to provide baseline data for the conservation efforts of these unique marine teleost. PMID:26868706

  5. Species and Size Composition of Seahorses (Genus Hippocampus, Family Syngnathidae) in the Coastal Waters and Local Market of Kota Kinabalu, Sabah, Malaysia.

    PubMed

    Shapawi, Rossita; Anyie, Adrian Leslie; Hussien, Muhammad Ali Syed; Zuldin, Wahidatul Husna

    2015-12-01

    Seahorse diversity (genus Hippocampus, Family Syngnathidae), species identification, size composition and sexual dimorphism were studied from November 2012 to March 2013 in selected coastal waters around Kota Kinabalu, Sabah and the local market trade. Six species of seahorses were identified in the study: (1) Hippocampus barbouri, (2) Hippocampus comes, (3) Hippocampus kelloggi, (4) Hippocampus kuda, (5) Hippocampus spinosissimus and (6) Hippocampus trimaculatus. All six species were sold at the local market, and the dried seahorses were obtained mainly by local fishermen using trawl by-catch method and traded as traditional medicine, souvenirs and other uses. Four species were identified by direct samplings in various different habitats of Kota Kinabalu coastal waters: (1) H. barbouri, (2) H. comes, (3) H. kuda, and (4) H. spinosissimus. Based on the results, H. comes was the largest in size among the four fresh/live species found (mean standard length [SL]: 148.25±1.26 mm), whereas H. barbouri was the smallest species (mean SL: 129±7.81 mm). For the dried samples, H. kelloggi was the largest (mean SL: 245.25±14.55 mm) and H. barbouri was the smallest (mean SL: 127.21±10.01 mm). No significant difference (p>0.05) was observed between the lengths of males and females in every seahorse species, and there was no sexual size dimorphism in any of the species. The findings from the study are significant to provide baseline data for the conservation efforts of these unique marine teleost.

  6. Effect of low air velocities on thermal homeostasis and comfort during exercise at space station operational temperature and humidity

    NASA Technical Reports Server (NTRS)

    Beumer, Ronald J.

    1989-01-01

    The effectiveness of different low air velocities in maintaining thermal comfort and homeostasis during exercise at space station operational temperature and humidity was investigated. Five male subjects exercised on a treadmill for successive ten minute periods at 60, 71, and 83 percent of maximum oxygen consumption at each of four air velocities, 30, 50, 80, and 120 ft/min, at 22 C and 62 percent relative humidity. No consistent trends or statistically significant differences between air velocities were found in body weight loss, sweat accumulation, or changes in rectal, skin, and body temperatures. Occurrence of the smallest body weight loss at 120 ft/min, the largest sweat accumulation at 30 ft/min, and the smallest rise in rectal temperature and the greatest drop in skin temperature at 120 ft/min all suggested more efficient evaporative cooling at the highest velocity. Heat storage at all velocities was evidenced by increased rectal and body temperatures; skin temperatures declined or increased only slightly. Body and rectal temperature increases corresponded with increased perception of warmth and slight thermal discomfort as exercise progressed. At all air velocities, mean thermal perception never exceeded warm and mean discomfort, greatest at 30 ft/min, was categorized at worst as uncomfortable; sensation of thermal neutrality and comfort returned rapidly after cessation of exercise. Suggestions for further elucidation of the effects of low air velocities on thermal comfort and homeostasis include larger numbers of subjects, more extensive skin temperature measurements and more rigorous analysis of the data from this study.

  7. Performance evaluation of the national early warning system for shallow landslides in Norway

    NASA Astrophysics Data System (ADS)

    Dahl, Mads-Peter; Piciullo, Luca; Devoli, Graziella; Colleuille, Hervé; Calvello, Michele

    2017-04-01

    As a consequence of the increased number of rainfall-and snowmelt-induced landslides (debris flows, debris slides, debris avalanches and slush flows) occurring in Norway, a national landslide early warning system (EWS) has been developed for monitoring and forecasting the hydro-meteorological conditions potentially necessary of triggering slope failures. The system, operational since 2013, is managed by the Norwegian Water Resources and Energy Directorate (NVE) and has been designed in cooperation with the Norwegian Public Road Administration (SVV), the Norwegian National Rail Administration (JBV) and the Norwegian Meteorological Institute (MET). Decision-making in the EWS is based upon hazard threshold levels, hydro-meteorological and real-time landslide observations as well as landslide inventory and susceptibility maps. Hazard threshold levels have been obtained through statistical analyses of historical landslides and modelled hydro-meteorological parameters. Daily hydro-meteorological conditions such as rainfall, snowmelt, runoff, soil saturation, groundwater level and frost depth have been derived from a distributed version of the hydrological HBV-model. Two different landslide susceptibility maps are used as supportive data in deciding daily warning levels. Daily alerts are issued throughout the country considering variable warning zones. Warnings are issued once per day for the following 3 days with an update possibility later during the day according to the information gathered by the monitoring variables. The performance of the EWS has been evaluated applying the EDuMaP method. In particular, the performance of warnings issued in Western Norway, in the period 2013-2014 has been evaluated using two different landslide datasets. The best performance is obtained for the smallest and more accurate dataset. Different performance results may be observed as a function of changing the landslide density criterion, Lden(k), (i.e., thresholds considered to differentiate among classes of landslide events) used as an input parameter within the EDuMaP method. To investigate this issue, a parametric analysis has been conducted; the results of the analysis show clear differences among computed performances when absolute or relative landslide density criteria are considered.

  8. Test-retest reliability and sensitivity of the 20-meter walk test among patients with knee osteoarthritis.

    PubMed

    Motyl, Jillian M; Driban, Jeffrey B; McAdams, Erica; Price, Lori Lyn; McAlindon, Timothy E

    2013-05-10

    The 20-meter walk test is a physical function measure commonly used in clinical research studies and rehabilitation clinics to measure gait speed and monitor changes in patients' physical function over time. Unfortunately, the reliability and sensitivity of this walk test are not well defined and, therefore, limit our ability to evaluate real changes in gait speed not attributable to normal variability. The aim of this study was to assess the test-restest reliability and sensitivity of the 20-meter walk test, at a self-selected pace, among patients with mild to moderate knee osteoarthritis (OA) and to suggest a standardized protocol for future test administration. This was a measurement reliability study. Fifteen consecutive people enrolled in a randomized-controlled trial of intra-articular corticosteroid injections for knee OA participated in this study. All participants completed 4 trials on 2 separate days, 7 to 21 days apart (8 trials total). Each day was divided into 2 sessions, which each involved 2 walking trials. We compared walk times between trials with Wilcoxon signed-rank tests. Similar analyses compared average walk times between sessions. To confirm these analyses, we also calculated Spearman correlation coefficients to assess the relationship between sessions. Finally, smallest detectable differences (SDD) were calculated to estimate the sensitivity of the 20-meter walk test. Wilcoxon signed-rank tests between trials within the same session demonstrated that trials in session 1 were significantly different and in the subsequent 3 sessions, the median differences between trials were not significantly different. Therefore, the first session of each day was considered a practice session, and the SDD between the second session of each day were calculated. SDD was -1.59 seconds (walking slower) and 0.15 seconds (walking faster). Practice trials and a standardized protocol should be used in administration of the 20-meter walk test. Changes in walk time between -1.59 seconds (walking slower) and 0.15 seconds (walking faster) should be considered within the range of normal variability of 20-meter walking speed. The primary limitation of our study was a small sample size, which may influence the generalizability of our findings.

  9. Chemical Exchange Saturation Transfer (CEST) MR Technique for Liver Imaging at 3.0 Tesla: an Evaluation of Different Offset Number and an After-Meal and Over-Night-Fast Comparison.

    PubMed

    Deng, Min; Chen, Shu-Zhong; Yuan, Jing; Chan, Queenie; Zhou, Jinyuan; Wáng, Yì-Xiáng J

    2016-04-01

    This study seeks to explore whether chemical exchange saturation transfer (CEST) magnetic resonance imaging (MRI) can detect liver composition changes between after-meal and over-night-fast statuses. Fifteen healthy volunteers were scanned on a 3.0-T human MRI scanner in the evening 1.5-2 h after dinner and in the morning after over-night (12-h) fasting. Among them, seven volunteers were scanned twice to assess the scan-rescan reproducibility. Images were acquired at offsets (n = 41, increment = 0.25 ppm) from -5 to 5 ppm using a turbo spin echo (TSE) sequence with a continuous rectangular saturation pulse. Amide proton transfer-weighted (APTw) and GlycoCEST signals were quantified with the asymmetric magnetization transfer ratio (MTRasym) at 3.5 ppm and the total MTRasym integrated from 0.5 to 1.5 ppm from the corrected Z-spectrum, respectively. To explore scan time reduction, CEST images were reconstructed using 31 offsets (with 20% time reduction) and 21 offsets (with 40% time reduction), respectively. For reproducibility, GlycoCEST measurements in 41 offsets showed the smallest scan-rescan mean measurements variability, indicated by the lowest mean difference of -0.049% (95% limits of agreement, -0.209 to 0.111%); for APTw, the smallest mean difference was found to be 0.112% (95% limits of agreement, -0.698 to 0.921%) in 41 offsets. Compared with after-meal, both GlycoCEST measurement and APTw measurement under different offset number decreased after 12-h fasting. However, as the offsets number decreased (41 offsets vs. 31 offsets vs. 21 offsets), GlycoCEST map and APTw map became more heterogeneous and noisier. Our results show that CEST liver imaging at 3.0 T has high sensitivity for fasting.

  10. Importance of sulfate radical anion formation and chemistry in heterogeneous OH oxidation of sodium methyl sulfate, the smallest organosulfate

    DOE PAGES

    Kwong, Kai Chung; Chim, Man Mei; Davies, James F.; ...

    2018-02-27

    Organosulfates are important organosulfur compounds present in atmospheric particles. While the abundance, composition, and formation mechanisms of organosulfates have been extensively investigated, it remains unclear how they transform and evolve throughout their atmospheric lifetime. To acquire a fundamental understanding of how organosulfates chemically transform in the atmosphere, this study investigates the heterogeneous OH radical-initiated oxidation of sodium methyl sulfate (CH 3SO 4Na) droplets, the smallest organosulfate detected in atmospheric particles, using an aerosol flow tube reactor at a high relative humidity (RH) of 85%. Aerosol mass spectra measured by a soft atmospheric pressure ionization source (direct analysis in real time,more » DART) coupled with a high-resolution mass spectrometer showed that neither functionalization nor fragmentation products are detected. Instead, the ion signal intensity of the bisulfate ion (HSO 4 -) has been found to increase significantly after OH oxidation. We postulate that sodium methyl sulfate tends to fragment into a formaldehyde (CH 2O) and a sulfate radical anion (SO 4 .-) upon OH oxidation. The formaldehyde is likely partitioned back to the gas phase due to its high volatility. The sulfate radical anion, similar to OH radical, can abstract a hydrogen atom from neighboring sodium methyl sulfate to form the bisulfate ion, contributing to the secondary chemistry. Kinetic measurements show that the heterogeneous OH reaction rate constant, k, is (3.79 ± 0.19) × 10 -13cm 3molecule -1s -1 with an effective OH uptake coefficient, γ eff, of 0.17 ± 0.03. While about 40% of sodium methyl sulfate is being oxidized at the maximum OH exposure (1.27 × 10 12molecule cm -3s), only a 3% decrease in particle diameter is observed. This can be attributed to a small fraction of particle mass lost via the formation and volatilization of formaldehyde. Overall, we firstly demonstrate that the heterogeneous OH oxidation of an organosulfate can lead to the formation of sulfate radical anion and produce inorganic sulfate. Fragmentation processes and sulfate radical anion chemistry play a key role in determining the compositional evolution of sodium methyl sulfate during heterogeneous OH oxidation.« less

  11. Importance of sulfate radical anion formation and chemistry in heterogeneous OH oxidation of sodium methyl sulfate, the smallest organosulfate

    NASA Astrophysics Data System (ADS)

    Chung Kwong, Kai; Chim, Man Mei; Davies, James F.; Wilson, Kevin R.; Nin Chan, Man

    2018-02-01

    Organosulfates are important organosulfur compounds present in atmospheric particles. While the abundance, composition, and formation mechanisms of organosulfates have been extensively investigated, it remains unclear how they transform and evolve throughout their atmospheric lifetime. To acquire a fundamental understanding of how organosulfates chemically transform in the atmosphere, this work investigates the heterogeneous OH radical-initiated oxidation of sodium methyl sulfate (CH3SO4Na) droplets, the smallest organosulfate detected in atmospheric particles, using an aerosol flow tube reactor at a high relative humidity (RH) of 85 %. Aerosol mass spectra measured by a soft atmospheric pressure ionization source (direct analysis in real time, DART) coupled with a high-resolution mass spectrometer showed that neither functionalization nor fragmentation products are detected. Instead, the ion signal intensity of the bisulfate ion (HSO4-) has been found to increase significantly after OH oxidation. We postulate that sodium methyl sulfate tends to fragment into a formaldehyde (CH2O) and a sulfate radical anion (SO4 ṡ -) upon OH oxidation. The formaldehyde is likely partitioned back to the gas phase due to its high volatility. The sulfate radical anion, similar to OH radical, can abstract a hydrogen atom from neighboring sodium methyl sulfate to form the bisulfate ion, contributing to the secondary chemistry. Kinetic measurements show that the heterogeneous OH reaction rate constant, k, is (3.79 ± 0.19) × 10-13 cm3 molecule-1 s-1 with an effective OH uptake coefficient, γeff, of 0.17 ± 0.03. While about 40 % of sodium methyl sulfate is being oxidized at the maximum OH exposure (1.27 × 1012 molecule cm-3 s), only a 3 % decrease in particle diameter is observed. This can be attributed to a small fraction of particle mass lost via the formation and volatilization of formaldehyde. Overall, we firstly demonstrate that the heterogeneous OH oxidation of an organosulfate can lead to the formation of sulfate radical anion and produce inorganic sulfate. Fragmentation processes and sulfate radical anion chemistry play a key role in determining the compositional evolution of sodium methyl sulfate during heterogeneous OH oxidation.

  12. Importance of sulfate radical anion formation and chemistry in heterogeneous OH oxidation of sodium methyl sulfate, the smallest organosulfate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kwong, Kai Chung; Chim, Man Mei; Davies, James F.

    Organosulfates are important organosulfur compounds present in atmospheric particles. While the abundance, composition, and formation mechanisms of organosulfates have been extensively investigated, it remains unclear how they transform and evolve throughout their atmospheric lifetime. To acquire a fundamental understanding of how organosulfates chemically transform in the atmosphere, this study investigates the heterogeneous OH radical-initiated oxidation of sodium methyl sulfate (CH 3SO 4Na) droplets, the smallest organosulfate detected in atmospheric particles, using an aerosol flow tube reactor at a high relative humidity (RH) of 85%. Aerosol mass spectra measured by a soft atmospheric pressure ionization source (direct analysis in real time,more » DART) coupled with a high-resolution mass spectrometer showed that neither functionalization nor fragmentation products are detected. Instead, the ion signal intensity of the bisulfate ion (HSO 4 -) has been found to increase significantly after OH oxidation. We postulate that sodium methyl sulfate tends to fragment into a formaldehyde (CH 2O) and a sulfate radical anion (SO 4 .-) upon OH oxidation. The formaldehyde is likely partitioned back to the gas phase due to its high volatility. The sulfate radical anion, similar to OH radical, can abstract a hydrogen atom from neighboring sodium methyl sulfate to form the bisulfate ion, contributing to the secondary chemistry. Kinetic measurements show that the heterogeneous OH reaction rate constant, k, is (3.79 ± 0.19) × 10 -13cm 3molecule -1s -1 with an effective OH uptake coefficient, γ eff, of 0.17 ± 0.03. While about 40% of sodium methyl sulfate is being oxidized at the maximum OH exposure (1.27 × 10 12molecule cm -3s), only a 3% decrease in particle diameter is observed. This can be attributed to a small fraction of particle mass lost via the formation and volatilization of formaldehyde. Overall, we firstly demonstrate that the heterogeneous OH oxidation of an organosulfate can lead to the formation of sulfate radical anion and produce inorganic sulfate. Fragmentation processes and sulfate radical anion chemistry play a key role in determining the compositional evolution of sodium methyl sulfate during heterogeneous OH oxidation.« less

  13. First record of live birth in Cretaceous ichthyosaurs: closing an 80 million year gap.

    PubMed

    Maxwell, Erin E; Caldwell, Michael W

    2003-08-07

    New fossils of embryonic ichthyosaurs are both the geologically youngest and the physically smallest known ichthyosaur embryos. The embryos are articulated, though only partially preserved, and are located within the body cavity of an adult, presumably the mother. The embryos and adult were found in association with several other individuals of differing size classes, all of which appear to be a new taxon of Cretaceous ichthyosaur. The material was collected from units of the Loon River Formation, Hay River, Northwest Territories, Canada. The implications of this new material to ichthyosaurian reproductive biology are discussed.

  14. Miniaturized high-precision piezo driven two axes stepper goniometer

    NASA Astrophysics Data System (ADS)

    Zhong, H.; Schwarz, A.; Wiesendanger, R.

    2014-04-01

    A miniaturized inertial stepper goniometer with two orthogonal axes (θ and φ axes) has been realized using four shear piezo based actuators arranged in a tetrahedral configuration tangent with a polished sapphire spherical rotor. The measured sensitivity is about 11.5 microdegree (μ°) per Volt. The smallest angular step size, achieved with a minimal peak-to-peak voltage Upp of 200 V is about 0.6 millidegree (m°). The crosstalk between both axes is below 10%. Our specific design is used to accurately position a glass fiber, but the concept can be utilized for many different applications as well.

  15. Cytotoxic and aryl hydrocarbon hydroxylase-inducing effects of laboratory rodent diets. A cell culture study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Toerroenen, R.; Pelkonen, K.; Kaerenlampi, S.

    1991-01-01

    Extracts of several rodent diets were studied for their cytotoxic and aryl hydrocarbon hydroxylase-inducing properties by an in vitro method. The cell culture system based on a mouse hepatoma cell line (Hepa-1) was shown to be convenient and sensitive method for screening of diets for these parameters implying the presence of compounds potentially harmful in vivo. Considerable differences among diets and batches were detected. Smallest effects were observed with a semipurified diet and with the unrefined diet which - contrary to other four unrefined diets - contained no fish.

  16. Effects of variable thermal diffusivity on the structure of convection

    NASA Astrophysics Data System (ADS)

    Shcheritsa, O. V.; Getling, A. V.; Mazhorova, O. S.

    2018-03-01

    The structure of multiscale convection in a thermally stratified plane horizontal fluid layer is investigated by means of numerical simulations. The thermal diffusivity is assumed to produce a thin boundary sublayer convectively much more unstable than the bulk of the layer. The simulated flow is a superposition of cellular structures with three different characteristic scales. In contrast to the largest convection cells, the smaller ones are localised in the upper portion of the layer. The smallest cells are advected by the larger-scale convective flows. The simulated flow pattern qualitatively resembles that observed on the Sun.

  17. The Minimum Clinically Important Difference of the Patient-rated Wrist Evaluation Score for Patients With Distal Radius Fractures.

    PubMed

    Walenkamp, Monique M J; de Muinck Keizer, Robert-Jan; Goslings, J Carel; Vos, Lara M; Rosenwasser, Melvin P; Schep, Niels W L

    2015-10-01

    The Patient-rated Wrist Evaluation (PRWE) is a commonly used instrument in upper extremity surgery and in research. However, to recognize a treatment effect expressed as a change in PRWE, it is important to be aware of the minimum clinically important difference (MCID) and the minimum detectable change (MDC). The MCID of an outcome tool like the PRWE is defined as the smallest change in a score that is likely to be appreciated by a patient as an important change, while the MDC is defined as the smallest amount of change that can be detected by an outcome measure. A numerical change in score that is less than the MCID, even when statistically significant, does not represent a true clinically relevant change. To our knowledge, the MCID and MDC of the PRWE have not been determined in patients with distal radius fractures. We asked: (1) What is the MCID of the PRWE score for patients with distal radius fractures? (2) What is the MDC of the PRWE? Our prospective cohort study included 102 patients with a distal radius fracture and a median age of 59 years (interquartile range [IQR], 48-66 years). All patients completed the PRWE questionnaire during each of two separate visits. At the second visit, patients were asked to indicate the degree of clinical change they appreciated since the previous visit. Accordingly, patients were categorized in two groups: (1) minimally improved or (2) no change. The groups were used to anchor the changes observed in the PRWE score to patients' perspectives of what was clinically important. We determined the MCID using an anchor-based receiver operator characteristic method. In this context, the change in the PRWE score was considered a diagnostic test, and the anchor (minimally improved or no change as noted by the patients from visit to visit) was the gold standard. The optimal receiver operator characteristic cutoff point calculated with the Youden index reflected the value of the MCID. In our study, the MCID of the PRWE was 11.5 points. The area under the curve was 0.54 (95% CI, 0.37-0.70) for the pain subscale and 0.71 (95% CI, 0.57-0.85) for the function subscale. We determined the MDC to be 11.0 points. We determined the MCID of the PRWE score for patients with distal radius fractures using the anchor-based approach and verified that the MDC of the PRWE was sufficiently small to detect our MCID. We recommend using an improvement on the PRWE of more than 11.5 points as the smallest clinically relevant difference when evaluating the effects of treatments and when performing sample-size calculations on studies of distal radius fractures.

  18. Entering the Next Dimension: Plant Genomes in 3D.

    PubMed

    Sotelo-Silveira, Mariana; Chávez Montes, Ricardo A; Sotelo-Silveira, Jose R; Marsch-Martínez, Nayelli; de Folter, Stefan

    2018-04-24

    After linear sequences of genomes and epigenomic landscape data, the 3D organization of chromatin in the nucleus is the next level to be explored. Different organisms present a general hierarchical organization, with chromosome territories at the top. Chromatin interaction maps, obtained by chromosome conformation capture (3C)-based methodologies, for eight plant species reveal commonalities, but also differences, among them and with animals. The smallest structures, found in high-resolution maps of the Arabidopsis genome, are single genes. Epigenetic marks (histone modification and DNA methylation), transcriptional activity, and chromatin interaction appear to be correlated, and whether structure is the cause or consequence of the function of interacting regions is being actively investigated. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Monogamy has a fixation advantage based on fitness variance in an ideal promiscuity group.

    PubMed

    Garay, József; Móri, Tamás F

    2012-11-01

    We consider an ideal promiscuity group of females, which implies that all males have the same average mating success. If females have concealed ovulation, then the males' paternity chances are equal. We find that male-based monogamy will be fixed in females' promiscuity group when the stochastic Darwinian selection is described by a Markov chain.We point out that in huge populations the relative advantage (difference between average fitness of different strategies) determines primarily the end of evolution; in the case of neutrality (means are equal) the smallest variance guarantees fixation (absorption) advantage; when the means and variances are the same, then the higher third moment determines which types will be fixed in the Markov chains.

  20. Objective and Subjective Evaluation of Reflecting and Diffusing Surfaces in Auditoria

    NASA Astrophysics Data System (ADS)

    Cox, Trevor John

    Available from UMI in association with The British Library. Requires signed TDF. The performance of reflectors and diffusers used in auditoria have been evaluated both objectively and subjectively. Two accurate systems have been developed to measure the scattering from surfaces via the cross correlation function. These have been used to measure the scattering from plane panels, curved panels and quadratic residue diffusers (QRDs). The scattering measurements have been used to test theoretical prediction methods based on the Helmholtz-Kirchhoff integral equation. Accurate prediction methods were found for all surfaces tested. The limitations of the more approximate methods have been defined. The assumptions behind Schroeder's design of the QRD have been tested and the local reacting admittance assumption found to be valid over a wide frequency range. It was found that the QRD only produces uniform scattering at low frequencies. For an on-axis source the scattering from a curved panel was as good as from a QRD. For an oblique source the QRD produced much more uniform scattering than the curved panel. The subjective measurements evaluated the smallest perceivable change in the early sound field, the part most influenced by reflectors and diffusers. A natural sounding simulation of a concert hall field within an anechoic chamber was used. Standard objective parameters were reasonable values when compared to values found in real halls and subjective preference measurements. A difference limen was measured for early lateral energy fraction (.048 +/-.005); inter aural cross correlation (.075 +/-.008); clarity index (.67 +/-.13 dB); and centre time (8.6 +/- 1.6 ms). It was found that: (i) when changes are made to diffusers and reflectors, changes in spatial impression will usually be larger than those in clarity; and (ii) acousticians can gain most by paying attention to lateral sound in auditoria. It was also found that: (i) diffuse reflections in the early sound field are not perceived differently from specular reflections; and (ii) the initial time delay gap is not significant to listener preference.

  1. Adapting the EDuMaP method to test the performance of the Norwegian early warning system for weather-induced landslides

    NASA Astrophysics Data System (ADS)

    Piciullo, Luca; Dahl, Mads-Peter; Devoli, Graziella; Colleuille, Hervé; Calvello, Michele

    2017-06-01

    The Norwegian national landslide early warning system (LEWS), operational since 2013, is managed by the Norwegian Water Resources and Energy Directorate and was designed for monitoring and forecasting the hydrometeorological conditions potentially triggering slope failures. Decision-making in the LEWS is based upon rainfall thresholds, hydrometeorological and real-time landslide observations as well as on landslide inventory and susceptibility maps. Daily alerts are issued throughout the country considering variable size warning zones. Warnings are issued once per day for the following 3 days and can be updated according to weather forecasts and information gathered by the monitoring network. The performance of the LEWS operational in Norway has been evaluated applying the EDuMaP method, which is based on the computation of a duration matrix relating number of landslides and warning levels issued in a warning zone. In the past, this method has been exclusively employed to analyse the performance of regional early warning models considering fixed warning zones. Herein, an original approach is proposed for the computation of the elements of the duration matrix in the case of early warning models issuing alerts on variable size areas. The approach has been used to evaluate the warnings issued in Western Norway, in the period 2013-2014, considering two datasets of landslides. The results indicate that the landslide datasets do not significantly influence the performance evaluation, although a slightly better performance is registered for the smallest dataset. Different performance results are observed as a function of the values adopted for one of the most important input parameters of EDuMaP, the landslide density criterion (i.e. setting the thresholds to differentiate among classes of landslide events). To investigate this issue, a parametric analysis has been conducted; the results of the analysis show significant differences among computed performances when absolute or relative landslide density criteria are considered.

  2. High inter-rater reliability, agreement, and convergent validity of Constant score in patients with clavicle fractures.

    PubMed

    Ban, Ilija; Troelsen, Anders; Kristensen, Morten Tange

    2016-10-01

    The Constant score (CS) has been the primary endpoint in most studies on clavicle fractures. However, the CS was not developed to assess patients with clavicle fractures. Our aim was to examine inter-rater reliability and agreement of the CS in patients with clavicle fractures. The secondary aim was to estimate the correlation between the CS and the Disabilities of the Arm, Shoulder and Hand score and the internal consistency of the 2 scores. On the basis of sample sizing, 36 patients (31 male and 5 female patients; mean age, 41.3 years) with clavicle fractures underwent standardized CS assessment at a mean of 6.8 weeks (SD, 1.0 weeks) after injury. Reliability and agreement of the CS were determined by 2 raters. The interclass correlation coefficient (ICC2,1), standard error of measurement, minimal detectable change, Cronbach α coefficient, and Pearson correlation coefficient were estimated. Inter-rater reliability of the total CS was excellent (interclass correlation coefficient, 0.94; 95% confidence interval, 0.88-0.97), with no systematic difference between the 2 raters (P = .75). The standard error of measurement (measurement error at the group level) was 4.9, whereas the minimal detectable change (smallest change needed to indicate a real change for an individual) was 13.6 CS points. The internal consistency of the 10 CS items was good, with a Cronbach α of .85, and we found a strong correlation (r = -0.92) between the CS and Disabilities of the Arm, Shoulder and Hand score. The CS was found to be reliable for assessing patients with clavicle fractures, especially at the group level. With high inter-rater reliability and agreement, in addition to good internal consistency, the standardized CS used in this study can be used for comparison of results from different settings. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  3. The mean, the median, and the St. Petersburg paradox

    PubMed Central

    Hayden, Benjamin Y.; Platt, Michael L.

    2013-01-01

    The St. Petersburg Paradox is a famous economic and philosophical puzzle that has generated numerous conflicting explanations. To shed empirical light on this phenomenon, we examined subjects’ bids for one St. Petersburg gamble with a real monetary payment. We found that bids were typically lower than twice the smallest payoff, and thus much lower than is generally supposed. We also examined bids offered for several hypothetical variants of the St. Petersburg Paradox. We found that bids were weakly affected by truncating the gamble, were strongly affected by repeats of the gamble, and depended linearly on the initial “seed” value of the gamble. One explanation, which we call the median heuristic, strongly predicts these data. Subjects following this strategy evaluate a gamble as if they were taking the median rather than the mean of the payoff distribution. Finally, we argue that the distribution of outcomes embodied in the St. Petersburg paradox is so divergent from the Gaussian form that the statistical mean is a poor estimator of expected value, so that the expected value of the St. Petersburg gamble is undefined. These results suggest that this classic paradox has a straightforward explanation rooted in the use of a statistical heuristic. PMID:24179560

  4. Glucose determination with fiber optic spectrometers

    NASA Astrophysics Data System (ADS)

    Starke, Eva; Kemper, Ulf; Barschdorff, Dieter

    1999-05-01

    Noninvasive blood glucose monitoring is the aim of research activities concerning the detection of small glucose concentrations dissolved in water and blood plasma. One approach for these measurements is the exploitation of absorption bands in the near infrared. However, the strong absorption of water represents a major difficulty. Transmission measurements of glucose dissolved in water and in blood plasma in the spectral region around 1600 nm with one- beam spectrometers and a FT-IR spectrometer are discussed. The evaluation of the data is carried out using a two-layer Lambert-Beer model and neural networks. In order to reduce the dimensions of a potential measuring device, an integrated acousto-optic tunable filter (AOTF) with an Erbium doped fiber amplifier as a radiation source is used. The fiber optic components are examined concerning their suitability. The smallest concentrations of glucose dissolved in water that can be separated are approximately 50 mg/dl. In the range of 50 mg/dl to 1000 mg/dl a correlation coefficient of 0.98 between real and estimated glucose concentrations is achieved using neural networks. In blood plasma so far glucose concentrations of about 100 mg/dl can be distinguished with good accuracy.

  5. The mean, the median, and the St. Petersburg paradox.

    PubMed

    Hayden, Benjamin Y; Platt, Michael L

    2009-06-01

    The St. Petersburg Paradox is a famous economic and philosophical puzzle that has generated numerous conflicting explanations. To shed empirical light on this phenomenon, we examined subjects' bids for one St. Petersburg gamble with a real monetary payment. We found that bids were typically lower than twice the smallest payoff, and thus much lower than is generally supposed. We also examined bids offered for several hypothetical variants of the St. Petersburg Paradox. We found that bids were weakly affected by truncating the gamble, were strongly affected by repeats of the gamble, and depended linearly on the initial "seed" value of the gamble. One explanation, which we call the median heuristic , strongly predicts these data. Subjects following this strategy evaluate a gamble as if they were taking the median rather than the mean of the payoff distribution. Finally, we argue that the distribution of outcomes embodied in the St. Petersburg paradox is so divergent from the Gaussian form that the statistical mean is a poor estimator of expected value, so that the expected value of the St. Petersburg gamble is undefined. These results suggest that this classic paradox has a straightforward explanation rooted in the use of a statistical heuristic.

  6. Resonant ultrasound spectroscopy and non-destructive testing

    NASA Astrophysics Data System (ADS)

    Migliori, A.; Darling, T. W.

    The use of mechanical resonances to test properties of materials is perhaps older than the industrial revolution. Early documented cases of British railroad engineers tapping the wheels of a train and using the sound to detect cracks perhaps mark the first real use of resonances to test the integrity of high-performance alloys. Attempts were made in the following years to understand the resonances of solids mathematically, based on the shape and composition. But Nobel Laureate Lord Rayleigh best summarized the state of affairs in 1894, stating 'the problem has, for the most part, resisted attack'. More recently, modern computers and electronics have enabled Anderson and co-workers with their work on minerals, and our work at Los Alamos on new materials and manufactured components to advance the use of resonances to a precision non-destructive testing tool that makes anisotropic modulus measurements, defect detection and geometry error detection routine. The result is that resonances can achieve the highest absolute accuracy for any dynamic modulus measurement technique, can be used on the smallest samples, and can also enable detection of errors in certain classes of precision manufactured components faster and more accurately than any other technique.

  7. Karyological features of wild and cultivated forms of myrtle (Myrtus communis, Myrtaceae).

    PubMed

    Serçe, S; Ekbiç, E; Suda, J; Gündüz, K; Kiyga, Y

    2010-03-09

    Myrtle is an evergreen shrub or small tree widespread throughout the Mediterranean region. In Turkey, both cultivated and wild forms, differing in plant and fruit size and fruit composition, can be found. These differences may have resulted from the domestication of the cultivated form over a long period of time. We investigated whether wild and cultivated forms of myrtle differ in karyological features (i.e., number of somatic chromosomes and relative genome size). We sampled two wild forms and six cultivated types of myrtle. All the samples had the same chromosome number (2n = 2x = 22). The results were confirmed by 4',6-diamidino-2-phenylindole (DAPI) flow cytometry. Only negligible variation (approximately 3%) in relative fluorescence intensity was observed among the different myrtle accessions, with wild genotypes having the smallest values. We concluded that despite considerable morphological differentiation, cultivated and wild myrtle genotypes in Turkey have similar karyological features.

  8. Seasonal variation of polycyclic aromatic hydrocarbons (PAHs) emissions in China.

    PubMed

    Zhang, Yanxu; Tao, Shu

    2008-12-01

    A regression model based on the provincial energy consumption data was developed to calculate the monthly proportions of residential energy consumption compared to the total year volume. This model was also validated by comparing with some survey and statistical data. With this model, a PAHs emission inventory with seasonal variation was developed. The seasonal variations of different sources in different regions of China and the spatial distribution of the major sources in different seasons were also achieved. The PAHs emissions were larger in the winter than in the summer, with a difference of about 1.3-folds between the months with the largest and the smallest emissions. Residential solid fuel combustion dominated the pattern of seasonal variation with the winter-time emissions as much as 1.6 times as that in the summer, while the emissions from wild fires and open fire straw burning was mainly concentrated during the spring and summer.

  9. 41 CFR 102-72.30 - What are the different types of delegations related to real estate leasing?

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... types of delegations related to real estate leasing? 102-72.30 Section 102-72.30 Public Contracts and... REGULATION REAL PROPERTY 72-DELEGATION OF AUTHORITY Delegation of Authority § 102-72.30 What are the different types of delegations related to real estate leasing? Delegations related to real estate leasing...

  10. 41 CFR 102-72.30 - What are the different types of delegations related to real estate leasing?

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... types of delegations related to real estate leasing? 102-72.30 Section 102-72.30 Public Contracts and... REGULATION REAL PROPERTY 72-DELEGATION OF AUTHORITY Delegation of Authority § 102-72.30 What are the different types of delegations related to real estate leasing? Delegations related to real estate leasing...

  11. 41 CFR 102-72.30 - What are the different types of delegations related to real estate leasing?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... types of delegations related to real estate leasing? 102-72.30 Section 102-72.30 Public Contracts and... REGULATION REAL PROPERTY 72-DELEGATION OF AUTHORITY Delegation of Authority § 102-72.30 What are the different types of delegations related to real estate leasing? Delegations related to real estate leasing...

  12. 41 CFR 102-72.30 - What are the different types of delegations related to real estate leasing?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... types of delegations related to real estate leasing? 102-72.30 Section 102-72.30 Public Contracts and... REGULATION REAL PROPERTY 72-DELEGATION OF AUTHORITY Delegation of Authority § 102-72.30 What are the different types of delegations related to real estate leasing? Delegations related to real estate leasing...

  13. Stereological estimation of the surface area and oxygen diffusing capacity of the respiratory stomach of the air-breathing armored catfish Pterygoplichthys anisitsi (Teleostei: Loricariidae).

    PubMed

    da Cruz, André Luis; Pedretti, Ana Carolina Elias; Fernandes, Marisa Narciso

    2009-05-01

    The stomach of Pterygoplichthys anisitsi has a thin, translucent wall and a simple squamous epithelium with an underlying dense capillary network. In the cardiac and pyloric regions, most cells have short microvilli distributed throughout the cell surface and their edges are characterized by short, densely packed microvilli. The mucosal layer of the stomach has two types of pavement epithelial cells that are similar to those in the aerial respiratory organs. Type 1 pavement epithelial cells, resembling the Type I pneumocyte in mammal lungs, are flat, with a large nucleus, and extend a thin sheet of cytoplasm on the underlying capillary. Type 2 cells, resembling the Type II pneumocyte, possess numerous mitochondria, a well-developed Golgi complex, rough endoplasmic reticulum, and numerous lamellar bodies in different stages of maturation. The gastric glands, distributed throughout the mucosal layer, also have several cells with many lamellar bodies. The total volume (air + tissue), tissue, and air capacity of the stomach when inflated, increase along with body mass. The surface-to-tissue-volume ratio of stomach varies from 108 cm(-1) in the smallest fish (0.084 kg) to 59 cm(-1) in the largest fish (0.60 kg). The total stomach surface area shows a low correlation to body mass. Nevertheless, the body-mass-specific surface area varied from 281.40 cm(2) kg(-1) in the smallest fish to 68.08 cm(2) kg(-1) in the largest fish, indicating a negative correlation to body mass (b = -0.76). The arithmetic mean barrier thickness between air and blood was 1.52 +/- 0.07 microm, whereas the harmonic mean thickness (tau(h)) of the diffusion barrier ranged from 0.40 to 0.74 microm. The anatomical diffusion factor (ADF = cm(2) microm(-1) kg(-1)) and the morphological O(2) diffusion capacity (D(morphol)O(2) = cm(3) min(-1) mmHg(-1) kg(-1)) are higher in the smallest specimen and lower in the largest one. In conclusion, the structure and morphometric data of P. anisitsi stomach indicate that this organ is adapted for oxygen uptake from air. (c) 2008 Wiley-Liss, Inc.

  14. Evaluation of mean-monthly streamflow-regression equations for Colorado, 2014

    USGS Publications Warehouse

    Kohn, Michael S.; Stevens, Michael R.; Bock, Andrew R.; Char, Stephen J.

    2015-01-01

    The median absolute differences between the observed and computed mean-monthly streamflow for Mountain, Northwest, and Southwest hydrologic regions are fairly uniform throughout the year, with the exception of late summer and early fall (July, August, and September), when each hydrologic region exhibits a substantial increase in median absolute percent difference. The greatest difference occurs in the Northwest hydrologic region, and the smallest difference occurs in the Mountain hydrologic region. The Rio Grande hydrologic region shows seasonal variation in median absolute percent difference with March, April, August, and September having a median absolute difference near or below 40 percent, and the remaining months of the year having a median absolute difference near or above 50 percent. In the Mountain, Northwest, and Southwest hydrologic regions, the mean-monthly streamflow equations perform the best during spring (March, April, and May). However, in the Rio Grande hydrologic region, the mean-monthly streamflow equations perform the best during late summer and early fall (August and September).

  15. Estimating Distance in Real and Virtual Environments: Does Order Make a Difference?

    PubMed Central

    Ziemer, Christine J.; Plumert, Jodie M.; Cremer, James F.; Kearney, Joseph K.

    2010-01-01

    This investigation examined how the order in which people experience real and virtual environments influences their distance estimates. Participants made two sets of distance estimates in one of the following conditions: 1) real environment first, virtual environment second; 2) virtual environment first, real environment second; 3) real environment first, real environment second; or 4) virtual environment first, virtual environment second. In Experiment 1, participants imagined how long it would take to walk to targets in real and virtual environments. Participants’ first estimates were significantly more accurate in the real than in the virtual environment. When the second environment was the same as the first environment (real-real and virtual-virtual), participants’ second estimates were also more accurate in the real than in the virtual environment. When the second environment differed from the first environment (real-virtual and virtual-real), however, participants’ second estimates did not differ significantly across the two environments. A second experiment in which participants walked blindfolded to targets in the real environment and imagined how long it would take to walk to targets in the virtual environment replicated these results. These subtle, yet persistent order effects suggest that memory can play an important role in distance perception. PMID:19525540

  16. [Experimental study on particle size distributions of an engine fueled with blends of biodiesel].

    PubMed

    Lu, Xiao-Ming; Ge, Yun-Shan; Han, Xiu-Kun; Wu, Si-Jin; Zhu, Rong-Fu; He, Chao

    2007-04-01

    The purpose of this study is to obtain the particle size distributions of an engine fueled biodiesel and its blends. A turbocharged DI diesel engine was tested on a dynamometer. A pump of 80 L/min and fiber glass filters with diameter of 90 mm were used to sample engine particles in exhaust pipe. Sampling duration was 10 minutes. Particle size distributions were measured by a laser diffraction particle size analyzer. Results indicated that higher engine speed resulted in smaller particle sizes and narrower distributions. The modes on distribution curves and mode variation were larger with dry samples than with wet samples (dry: around 10 - 12 microm vs. wet: around 4 - 10 microm). At low speed, Sauter mean diameter d32 of dry samples was the biggest with B100, the smallest with diesel fuel, and among them with B20, while at high speed, d32 the biggest with B20, the smallest with B100, and in middle with diesel. Median diameter d(0.5) also reflected the results. Except for 2 000 r/min, d32 of wet with B20 is the biggest, the smallest with diesel, and in middle with B100. The large mode variation resulted in increase of d32.

  17. The Extremely Low Activity Comet 209P/LINEAR During Its Extraordinary Close Approach in 2014

    NASA Astrophysics Data System (ADS)

    Schleicher, David G.; knight, Matthew m.

    2016-10-01

    We present results from our observing campaign of Comet 209P/LINEAR during its exceptionally close approach to Earth during 2014 May, the third smallest perigee of any comet in two centuries. These circumstances permitted us to pursue several studies of this intrinsically faint object, including measurements of gas and dust production rates, searching for coma morphology, and direct detection of the nucleus to measure its properties. Indeed, we successfully measured the lowest water production rates of an intact comet in over 35 years and a corresponding smallest active area, ∼0.007 km2. When combined with the nucleus size found from radar, this also yields the smallest active fraction for any comet, ∼0.024%. In all, this strongly suggests that 209P/LINEAR is on its way to becoming an inert object. The nucleus was detected but could not easily be disentangled from the inner coma due to seeing variations and changing spatial scales. Even so, we were able to measure a double-peaked lightcurve consistent with the shorter of two viable rotational periods found by Hergenrother. Radial profiles of the dust coma are quite steep, similar to that observed for some other very anemic comets, and suggest that vaporizing icy grains are present.

  18. Some lemma on spectrum of eigen value regarding power method

    NASA Astrophysics Data System (ADS)

    Jamali, A. R. M. Jalal Uddin; Alam, Md. Sah

    2017-04-01

    Eigen value problems arise in almost all science and engineering fields. There exist some smart methods in literature in which most of them are able to find only Eigen values but could not find corresponding Eigen vectors. There exist many engineering as well as scientific fields in which both largest as well as smallest Eigen pairs are required. Power method is very simple but a powerful tool for finding largest Eigen value and corresponding Eigen vector (Eigen-pair). Again Inverse Power method is applied to find out smallest Eigen-pair and/or desire Eigen-pairs. But it is known that Inverse Power method is computationally very costly. On the other hand by using shifting property, Power method can find further Eigen-pairs. But the position of this Eigen value in the set of spectrum of the Eigen values is not identified. In this regard we proposed four lemma associate with Modified Power method. Each Lemma is proved ornately. The Modified Power method is implemented and illustrates an example for the verification of the Lemma. By using lemma the modified power algorithm is able to find out both largest and smallest Eigen-pairs successfully and efficiently in some cases. Moreover by the help of the Lemma, algorithm is able to detect the nature (positive and negative) of the Eigen values.

  19. Temperature-Correlated Changes in Phytoplankton Community Structure Are Restricted to Polar Waters.

    PubMed

    Ward, Ben A

    2015-01-01

    Globally distributed observations of size-fractionated chlorophyll a and temperature were used to incorporate temperature dependence into an existing semi-empirical model of phytoplankton community size structure. The additional temperature-dependent term significantly increased the model's ability to both reproduce and predict observations of chlorophyll a size-fractionation at temperatures below 2°C. The most notable improvements were in the smallest (picoplankton) size-class, for which overall model fit was more than doubled, and predictive skill was increased by approximately 40%. The model was subsequently applied to generate global maps for three phytoplankton size classes, on the basis of satellite-derived estimates of surface chlorophyll a and sea surface temperature. Polar waters were associated with marked decline in the chlorophyll a biomass of the smallest cells, relative to lower latitude waters of equivalent total chlorophyll a. In the same regions a complementary increase was seen in the chlorophyll a biomass of larger size classes. These findings suggest that a warming and stratifying ocean will see a poleward expansion of the habitat range of the smallest phytoplankton, with the possible displacement of some larger groups that currently dominate. There was no evidence of a strong temperature dependence in tropical or sub-tropical regions, suggesting that future direct temperature effects on community structure at lower latitudes may be small.

  20. Lower limits of ornithischian dinosaur body size inferred from a new Upper Jurassic heterodontosaurid from North America

    PubMed Central

    Butler, Richard J.; Galton, Peter M.; Porro, Laura B.; Chiappe, Luis M.; Henderson, Donald M.; Erickson, Gregory M.

    2010-01-01

    The extremes of dinosaur body size have long fascinated scientists. The smallest (<1 m length) known dinosaurs are carnivorous saurischian theropods, and similarly diminutive herbivorous or omnivorous ornithischians (the other major group of dinosaurs) are unknown. We report a new ornithischian dinosaur, Fruitadens haagarorum, from the Late Jurassic of western North America that rivals the smallest theropods in size. The largest specimens of Fruitadens represent young adults in their fifth year of development and are estimated at just 65–75 cm in total body length and 0.5–0.75 kg body mass. They are thus the smallest known ornithischians. Fruitadens is a late-surviving member of the basal dinosaur clade Heterodontosauridae, and is the first member of this clade to be described from North America. The craniodental anatomy and diminutive body size of Fruitadens suggest that this taxon was an ecological generalist with an omnivorous diet, thus providing new insights into morphological and palaeoecological diversity within Dinosauria. Late-surviving (Late Jurassic and Early Cretaceous) heterodontosaurids are smaller and less ecologically specialized than Early (Late Triassic and Early Jurassic) heterodontosaurids, and this ecological generalization may account in part for the remarkable 100-million-year-long longevity of the clade. PMID:19846460

  1. Molindone: effects in pigeons responding under conditional discrimination tasks.

    PubMed

    Picker, M J; Cleary, J P; Berens, K; Oliveto, A H; Dykstra, L A

    1989-02-01

    Pigeons were trained to respond under three conditional discrimination procedures; 1) a fixed-consecutive-number procedure with (FCN 8-SD) and without (FCN 8) an added external discriminative stimulus, 2) a delayed matching-to-sample (DMTS) procedure using 0-sec, 2-sec and 8-sec delay intervals, and 3) a repeated acquisition of behavioral chains (RA) procedure using a four-link response chain with three stimulus keys. The atypical neuroleptic agent molindone decreased accuracy under the FCN 8 at doses that had no effect on accuracy under the FCN 8-SD. Under the DMTS procedure, molindone-induced decreases in accuracy were directly related to the delay interval, with the largest relative decrements obtained at the 8-sec delay and the smallest at the 0-sec delay. Under the RA procedure, molindone decreased accuracy at doses that had little or no effect on the number of correct responses emitted. Relative to control values, molindone-induced decreases in accuracy were smallest under the DMTS and FCN 8-SD procedures and largest under the FCN 8 and RA procedures. The differential effects obtained with molindone under each of these procedures illustrate the need to employ a variety of assays when determining the behavioral actions of neuroleptics. In addition, this battery of behavioral tests may provide a useful tool for assessing the different neurochemical actions of neuroleptic compounds.

  2. Bound on largest r ∼< 0.1 from sub-Planckian excursions of inflaton

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chatterjee, Arindam; Mazumdar, Anupam, E-mail: arindam@hri.res.in, E-mail: a.mazumdar@lancaster.ac.uk

    2015-01-01

    In this paper we will discuss the range of large tensor to scalar ratio, r, obtainable from a sub-Planckian excursion of a single, slow roll driven inflaton field. In order to obtain a large r for such a scenario one has to depart from a monotonic evolution of the slow roll parameters in such a way that one still satisfies all the current constraints of \\texttt(Planck), such as the scalar amplitude, the tilt in the scalar power spectrum, running and running of the tilt close to the pivot scale. Since the slow roll parameters evolve non-monotonically, we will also considermore » the evolution of the power spectrum on the smallest scales, i.e. at P{sub s}(k ∼ 10{sup 16} Mpc{sup −1})∼< 10{sup −2}, to make sure that the amplitude does not become too large. All these constraints tend to keep the tensor to scalar ratio, r ∼< 0.1. We scan three different kinds of potential for supersymmetric flat directions and obtain the benchmark points which satisfy all the constraints. We also show that it is possible to go beyond r ∼> 0.1 provided we relax the upper bound on the power spectrum on the smallest scales.« less

  3. From isolated light-harvesting complexes to the thylakoid membrane: a single-molecule perspective

    NASA Astrophysics Data System (ADS)

    Gruber, J. Michael; Malý, Pavel; Krüger, Tjaart P. J.; Grondelle, Rienk van

    2018-01-01

    The conversion of solar radiation to chemical energy in plants and green algae takes place in the thylakoid membrane. This amphiphilic environment hosts a complex arrangement of light-harvesting pigment-protein complexes that absorb light and transfer the excitation energy to photochemically active reaction centers. This efficient light-harvesting capacity is moreover tightly regulated by a photoprotective mechanism called non-photochemical quenching to avoid the stress-induced destruction of the catalytic reaction center. In this review we provide an overview of single-molecule fluorescence measurements on plant light-harvesting complexes (LHCs) of varying sizes with the aim of bridging the gap between the smallest isolated complexes, which have been well-characterized, and the native photosystem. The smallest complexes contain only a small number (10-20) of interacting chlorophylls, while the native photosystem contains dozens of protein subunits and many hundreds of connected pigments. We discuss the functional significance of conformational dynamics, the lipid environment, and the structural arrangement of this fascinating nano-machinery. The described experimental results can be utilized to build mathematical-physical models in a bottom-up approach, which can then be tested on larger in vivo systems. The results also clearly showcase the general property of biological systems to utilize the same system properties for different purposes. In this case it is the regulated conformational flexibility that allows LHCs to switch between efficient light-harvesting and a photoprotective function.

  4. Floral meristem size and organ number correlation in Eucryphia (Cunoniaceae).

    PubMed

    Bull-Hereñu, Kester; Ronse de Craene, Louis; Pérez, Fernanda

    2018-05-01

    We present a comparative flower ontogenetic study in five species of the genus Eucryphia with the aim of testing whether differences in the organ number observed can be explained by changes in the meristematic size of floral meristem and floral organs. Species native to Oceania, viz. E. milliganii, E. lucida and E. moorei, have the smallest gynoecia with ca. 6 carpels, while the Chilean E. glutinosa and E. cordifolia present more than ten carpels. E. milliganii has the smallest flower with the lowest stamen number (ca. 50), while the other species produce around 200 stamens and more. Standardized measurements of meristematic sectors were taken in 49 developing flowers that were classified into three well-defined ontogenetic stages. Sizes of meristems varied significantly among species within each developmental stage as revealed by ANOVA analyses. Significant regressions between organ number and corresponding meristem size were consistent with the premise that a larger meristem size prior to organ initiation could be determining for a higher organ number. Flower organogenesis in Eucryphia also involves relevant meristem expansion while the organs are initiated, which results in a particular androecium patterning with a chaotic stamen arrangement. Meristem expansion also appears to be slower but more extensive in species with larger initial meristematic size, suggesting that flower phenotype can be determined in ontogeny by this heterochronic interplay of space and time.

  5. Particulate Size of Microalgal Biomass Affects Hydrolysate Properties and Bioethanol Concentration

    PubMed Central

    Harun, Razif; Danquah, Michael K.; Thiruvenkadam, Selvakumar

    2014-01-01

    Effective optimization of microalgae-to-bioethanol process systems hinges on an in-depth characterization of key process parameters relevant to the overall bioprocess engineering. One of the such important variables is the biomass particle size distribution and the effects on saccharification levels and bioethanol titres. This study examined the effects of three different microalgal biomass particle size ranges, 35 μm ≤ x ≤ 90 μm, 125 μm ≤ x ≤ 180 μm, and 295 μm ≤ x ≤ 425 μm, on the degree of enzymatic hydrolysis and bioethanol production. Two scenarios were investigated: single enzyme hydrolysis (cellulase) and double enzyme hydrolysis (cellulase and cellobiase). The glucose yield from biomass in the smallest particle size range (35 μm ≤ x ≤ 90 μm) was the highest, 134.73 mg glucose/g algae, while the yield from biomass in the larger particle size range (295 μm ≤ x ≤ 425 μm) was 75.45 mg glucose/g algae. A similar trend was observed for bioethanol yield, with the highest yield of 0.47 g EtOH/g glucose obtained from biomass in the smallest particle size range. The results have shown that the microalgal biomass particle size has a significant effect on enzymatic hydrolysis and bioethanol yield. PMID:24971327

  6. Evaluation of anti-microbial activities of ZnO, citric acid and a mixture of both against Propionibacterium acnes.

    PubMed

    Bae, J Y; Park, S N

    2016-12-01

    In this study, anti-microbial activities of ZnO of three different particle sizes of citric acid (CA) and of mixtures of ZnO and CA were confirmed against Propionibacterium acnes. ZnO with the smallest particle size showed relatively high anti-microbial activity by disc diffusion assay and broth macrodilution assay. The mixtures of ZnO and CA also showed relatively high anti-microbial activity when the particle size of ZnO was the smallest. Furthermore, anti-microbial activities of ZnO, CA and the mixtures of ZnO and CA were compared through the checkerboard assay. The results indicated that a 1 : 1 ratio of ZnO and CA resulted in the highest anti-microbial activity. The substances were confirmed to have synergic anti-microbial effects. With the time-kill curve assay, the mixture of ZnO-containing CA reduced the surviving microbial content the most after 24 h. The results of our study suggest that ZnO may not only be an anti-microbial ingredient for the prevention of and treatment of acne. The results of our study suggest that ZnO may be an anti-microbial ingredient for the prevention of and treatment of acne when mixed with CA. © 2016 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  7. Combining Deep and Handcrafted Image Features for Presentation Attack Detection in Face Recognition Systems Using Visible-Light Camera Sensors

    PubMed Central

    Nguyen, Dat Tien; Pham, Tuyen Danh; Baek, Na Rae; Park, Kang Ryoung

    2018-01-01

    Although face recognition systems have wide application, they are vulnerable to presentation attack samples (fake samples). Therefore, a presentation attack detection (PAD) method is required to enhance the security level of face recognition systems. Most of the previously proposed PAD methods for face recognition systems have focused on using handcrafted image features, which are designed by expert knowledge of designers, such as Gabor filter, local binary pattern (LBP), local ternary pattern (LTP), and histogram of oriented gradients (HOG). As a result, the extracted features reflect limited aspects of the problem, yielding a detection accuracy that is low and varies with the characteristics of presentation attack face images. The deep learning method has been developed in the computer vision research community, which is proven to be suitable for automatically training a feature extractor that can be used to enhance the ability of handcrafted features. To overcome the limitations of previously proposed PAD methods, we propose a new PAD method that uses a combination of deep and handcrafted features extracted from the images by visible-light camera sensor. Our proposed method uses the convolutional neural network (CNN) method to extract deep image features and the multi-level local binary pattern (MLBP) method to extract skin detail features from face images to discriminate the real and presentation attack face images. By combining the two types of image features, we form a new type of image features, called hybrid features, which has stronger discrimination ability than single image features. Finally, we use the support vector machine (SVM) method to classify the image features into real or presentation attack class. Our experimental results indicate that our proposed method outperforms previous PAD methods by yielding the smallest error rates on the same image databases. PMID:29495417

  8. Achieving simplified disease activity index remission in patients with active rheumatoid arthritis is associated with subsequent good functional and structural outcomes in a real-world clinical setting under a treat-to-target strategy.

    PubMed

    Hirano, Fumio; Yokoyama, Waka; Yamazaki, Hayato; Amano, Koichi; Kawakami, Atsushi; Hayashi, Taichi; Tamura, Naoto; Yasuda, Shinsuke; Dobashi, Hiroaki; Fujii, Takao; Ito, Satoshi; Kaneko, Yuko; Matsui, Toshihiro; Okuda, Yasuaki; Saito, Kazuyoshi; Suzuki, Fumihito; Yoshimi, Ryusuke; Sakai, Ryoko; Koike, Ryuji; Kohsaka, Hitoshi; Miyasaka, Nobuyuki; Harigai, Masayoshi

    2017-09-01

    To verify predictive validity of simplified disease activity index (SDAI) remission for subsequent functional and structural outcomes in real-world clinical settings under a treat-to-target strategy (T2T). In this multicenter, prospective cohort study, T2T was implemented in rheumatoid arthritis (RA) patients with moderate-to-high disease activity. SDAI or clinical disease activity index (CDAI) was assessed every 12 weeks, and treatment was adjusted to achieve clinical remission or low disease activity (LDA). Multivariate logistic regression models were used to examine the associations of SDAI remission (≤3.3) at week 24 with the health assessment questionnaire-disability index (HAQ-DI) ≤ 0.5 or with the delta van der Heijde-modified total Sharp score (ΔvdH-mTSS) 

  9. A comparison of defect size and film quality obtained from Film digitized image and digital image radiographs

    NASA Astrophysics Data System (ADS)

    Kamlangkeng, Poramate; Asa, Prateepasen; Mai, Noipitak

    2014-06-01

    Digital radiographic testing is an acceptable premature nondestructive examination technique. Its performance and limitation comparing to the old technique are still not widely well known. In this paper conducted the study on the comparison of the accuracy of the defect size measurement and film quality obtained from film and digital radiograph techniques by testing in specimens and known size sample defect. Initially, one specimen was built with three types of internal defect; which are longitudinal cracking, lack of fusion, and porosity. For the known size sample defect, it was machined various geometrical size for comparing the accuracy of the measuring defect size to the real size in both film and digital images. To compare the image quality by considering at smallest detectable wire and the three defect images. In this research used Image Quality Indicator (IQI) of wire type 10/16 FE EN BS EN-462-1-1994. The radiographic films were produced by X-ray and gamma ray using Kodak AA400 size 3.5x8 inches, while the digital images were produced by Fuji image plate type ST-VI with 100 micrometers resolution. During the tests, a radiator GE model MF3 was implemented. The applied energy is varied from 120 to 220 kV and the current from 1.2 to 3.0 mA. The intensity of Iridium 192 gamma ray is in the range of 24-25 Curie. Under the mentioned conditions, the results showed that the deviation of the defect size measurement comparing to the real size obtained from the digital image radiographs is below than that of the film digitized, whereas the quality of film digitizer radiographs is higher in comparison.

  10. Combining Deep and Handcrafted Image Features for Presentation Attack Detection in Face Recognition Systems Using Visible-Light Camera Sensors.

    PubMed

    Nguyen, Dat Tien; Pham, Tuyen Danh; Baek, Na Rae; Park, Kang Ryoung

    2018-02-26

    Although face recognition systems have wide application, they are vulnerable to presentation attack samples (fake samples). Therefore, a presentation attack detection (PAD) method is required to enhance the security level of face recognition systems. Most of the previously proposed PAD methods for face recognition systems have focused on using handcrafted image features, which are designed by expert knowledge of designers, such as Gabor filter, local binary pattern (LBP), local ternary pattern (LTP), and histogram of oriented gradients (HOG). As a result, the extracted features reflect limited aspects of the problem, yielding a detection accuracy that is low and varies with the characteristics of presentation attack face images. The deep learning method has been developed in the computer vision research community, which is proven to be suitable for automatically training a feature extractor that can be used to enhance the ability of handcrafted features. To overcome the limitations of previously proposed PAD methods, we propose a new PAD method that uses a combination of deep and handcrafted features extracted from the images by visible-light camera sensor. Our proposed method uses the convolutional neural network (CNN) method to extract deep image features and the multi-level local binary pattern (MLBP) method to extract skin detail features from face images to discriminate the real and presentation attack face images. By combining the two types of image features, we form a new type of image features, called hybrid features, which has stronger discrimination ability than single image features. Finally, we use the support vector machine (SVM) method to classify the image features into real or presentation attack class. Our experimental results indicate that our proposed method outperforms previous PAD methods by yielding the smallest error rates on the same image databases.

  11. Responsive Hydrogel-based Photonic Nanochains for Microenvironment Sensing and Imaging in Real Time and High Resolution.

    PubMed

    Luo, Wei; Cui, Qian; Fang, Kai; Chen, Ke; Ma, Huiru; Guan, Jianguo

    2018-01-17

    Microenvironment sensing and imaging are of importance in microscale zones like microreactors, microfluidic systems, and biological cells. But they are so far implemented only based on chemical colors from dyes or quantum dots, which suffered either from photobleaching, quenching, or photoblinking behaviors, or from limited color gamut. In contrast, structural colors from hydrogel-based photonic crystals (PCs) may be stable and tunable in the whole visible spectrum by diffraction peak shift, facilitating the visual detection with high accuracy. However, the current hydrogel-based PCs are all inappropriate for microscale detection due to the bulk size. Here we demonstrate the smallest hydrogel-based PCs, responsive hydrogel-based photonic nanochains with high-resolution and real-time response, by developing a general hydrogen bond-guided template polymerization method. A variety of mechanically separated stimuli-responsive hydrogel-based photonic nanochains have been obtained in a large scale including those responding to pH, solvent, and temperature. Each of them has a submicrometer diameter and is composed of individual one-dimensional periodic structure of magnetic particles locked by a tens-of-nanometer-thick peapod-like responsive hydrogel shell. Taking the pH-responsive hydrogel-based photonic nanochains, for example, pH-induced hydrogel volume change notably alters the nanochain length, resulting in a significant variation of the structural color. The submicrometer size endows the nanochains with improved resolution and response time by 2-3 orders of magnitude than the previous counterparts. Our results for the first time validate the feasibility of using structural colors for microenvironment sensing and imaging and may further promote the applications of responsive PCs, such as in displays and printing.

  12. Properties of the optimal trajectories for coplanar, aeroassisted orbital transfer

    NASA Technical Reports Server (NTRS)

    Miele, A.; Wang, T.; Deaton, A. W.

    1990-01-01

    The optimization of trajectories for coplaner, aeroassisted orbital transfer (AOT) from a high Earth orbit (HEO) to a low Earth orbit (LEO) is examined. In particular, HEO can be a geosynchronous Earth orbit (GEO). It is assumed that the initial and final orbits are circular, that the gravitational field is central and is governed by the inverse square law, and that two impulses are employed, one at HEO exit and one at LEO entry. During the atmospheric pass, the trajectory is controlled via the lift coefficient in such a way that the total characteristic velocity is minimized. First, an ideal optimal trajectory is determined analytically for lift coefficient unbounded. This trajectory is called grazing trajectory, because the atmospheric pass is made by flying at constant altitude along the edge of the atmosphere until the excess velocity is depleted. For the grazing trajectory, the lift coefficient varies in such a way that the lift, the centrifugal force due to the Earth's curvature, the weight, and the Coriolis force due to the Earth's rotation are in static balance. Also, the grazing trajectory minimizes the total characteristic velocity and simultaneously nearly minimizes the peak values of the altitude drop, dynamic pressure, and heating rate. Next, starting from the grazing trajectory results, a real optimal trajectory is determined numerically for the lift coefficient bounded from both below and above. This trajectory is characterized by atmospheric penetration with the smallest possible entry angle, followed by flight at the lift coefficient lower bound. Consistently with the grazing trajectory behavior, the real optimal trajectory minimizes the total characteristic velocity and simultaneously nearly minimizes the peak values of the altitude drop, the dynamic pressure, and the heating rate.

  13. Functionality based detection of airborne engineered nanoparticles in quasi real time: a new type of detector and a new metric.

    PubMed

    Neubauer, Nicole; Seipenbusch, Martin; Kasper, Gerhard

    2013-08-01

    A new type of detector which we call the Catalytic Activity Aerosol Monitor (CAAM) was investigated towards its capability to detect traces of commonly used industrial catalysts in ambient air in quasi real time. Its metric is defined as the catalytic activity concentration (CAC) expressed per volume of sampled workplace air. We thus propose a new metric which expresses the presence of nanoparticles in terms of their functionality - in this case a functionality of potential relevance for damaging effects - rather than their number, surface, or mass concentration in workplace air. The CAAM samples a few micrograms of known or anticipated airborne catalyst material onto a filter first and then initiates a chemical reaction which is specific to that catalyst. The concentration of specific gases is recorded using an IR sensor, thereby giving the desired catalytic activity. Due to a miniaturization effort, the laboratory prototype is compact and portable. Sensitivity and linearity of the CAAM response were investigated with catalytically active palladium and nickel nano-aerosols of known mass concentration and precisely adjustable primary particle size in the range of 3-30 nm. With the miniature IR sensor, the smallest detectable particle mass was found to be in the range of a few micrograms, giving estimated sampling times on the order of minutes for workplace aerosol concentrations typically reported in the literature. Tests were also performed in the presence of inert background aerosols of SiO2, TiO2, and Al2O3. It was found that the active material is detectable via its catalytic activity even when the particles are attached to a non-active background aerosol.

  14. A k-mer-based barcode DNA classification methodology based on spectral representation and a neural gas network.

    PubMed

    Fiannaca, Antonino; La Rosa, Massimo; Rizzo, Riccardo; Urso, Alfonso

    2015-07-01

    In this paper, an alignment-free method for DNA barcode classification that is based on both a spectral representation and a neural gas network for unsupervised clustering is proposed. In the proposed methodology, distinctive words are identified from a spectral representation of DNA sequences. A taxonomic classification of the DNA sequence is then performed using the sequence signature, i.e., the smallest set of k-mers that can assign a DNA sequence to its proper taxonomic category. Experiments were then performed to compare our method with other supervised machine learning classification algorithms, such as support vector machine, random forest, ripper, naïve Bayes, ridor, and classification tree, which also consider short DNA sequence fragments of 200 and 300 base pairs (bp). The experimental tests were conducted over 10 real barcode datasets belonging to different animal species, which were provided by the on-line resource "Barcode of Life Database". The experimental results showed that our k-mer-based approach is directly comparable, in terms of accuracy, recall and precision metrics, with the other classifiers when considering full-length sequences. In addition, we demonstrate the robustness of our method when a classification is performed task with a set of short DNA sequences that were randomly extracted from the original data. For example, the proposed method can reach the accuracy of 64.8% at the species level with 200-bp fragments. Under the same conditions, the best other classifier (random forest) reaches the accuracy of 20.9%. Our results indicate that we obtained a clear improvement over the other classifiers for the study of short DNA barcode sequence fragments. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Exergames for women with fibromyalgia: a randomised controlled trial to evaluate the effects on mobility skills, balance and fear of falling.

    PubMed

    Collado-Mateo, Daniel; Dominguez-Muñoz, Francisco J; Adsuar, Jose C; Merellano-Navarro, Eugenio; Gusi, Narcis

    2017-01-01

    Exergames are a new form of rehabilitation that combine the characteristics of physical exercise and the benefits of non-immersive virtual reality (VR). Effects of this novel therapy in women fibromyalgia are still unknown. The objective was to evaluate the effects of exergame-based intervention on mobility skills, balance and fear of falling in women with fibromyalgia. This study was a randomized controlled trial with concealed allocation. Seventy-six women with fibromyalgia were divided into two groups: the exercise group received an eight week intervention based on exergames, while the control group continued their usual activities. Mobility skills were evaluated using the timed up and go test, while balance was assessed using the functional reach test, and the CTSIB protocol. Fear of falling was evaluated on a scale of 0-100 (0, no fear; 100, extreme fear). Measurements were performed before and after the intervention. A repeated-measures linear mixed model was used to compare the effects of the intervention between the two groups. The exercise group was significantly quicker than the control group in the timed up and go test (MD, -0.71; 95% CI [-1.09-0.32]; p  < 0.001). There were also significant improvements in functional reach and a reduced fear of falling (MD, 4.34; 95% CI [1.39-7.30]; p  = 0.005 and MD, -9.85; 95% CI [-0.19--0.08]; p  = 0.048, respectively). The improved TUG observed herein was better than the smallest real difference. Based on the results on mobility skills, balance and fear of falling, exergames may be an effective tool as a therapy for women with fibromyalgia.

  16. Spatially-global integration of closed, fragmented contours by finding the shortest-path in a log-polar representation

    PubMed Central

    Kwon, TaeKyu; Agrawal, Kunal; Li, Yunfeng; Pizlo, Zygmunt

    2015-01-01

    Finding the occluding contours of objects in real 2D retinal images of natural 3D scenes is done by determining, which contour fragments are relevant, and the order in which they should be connected. We developed a model that finds the closed contour represented in the image by solving a shortest path problem that uses a log-polar representation of the image; the kind of representation known to exist in area V1 of the primate cortex. The shortest path in a log-polar representation favors the smooth, convex and closed contours in the retinal image that have the smallest number of gaps. This approach is practical because finding a globally-optimal solution to a shortest path problem is computationally easy. Our model was tested in four psychophysical experiments. In the first two experiments, the subject was presented with a fragmented convex or concave polygon target among a large number of unrelated pieces of contour (distracters). The density of these pieces of contour was uniform all over the screen to minimize spatially-local cues. The orientation of each target contour fragment was randomly perturbed by varying the levels of jitter. Subjects drew a closed contour that represented the target’s contour on a screen. The subjects’ performance was nearly perfect when the jitter-level was low. Their performance deteriorated as jitter-levels were increased. The performance of our model was very similar to our subjects’. In two subsequent experiments, the subject was asked to discriminate a briefly-presented egg-shaped object while maintaining fixation at several different positions relative to the closed contour of the shape. The subject’s discrimination performance was affected by the fixation position in much the same way as the model’s. PMID:26241462

  17. How Many Protein Sequences Fold to a Given Structure? A Coevolutionary Analysis.

    PubMed

    Tian, Pengfei; Best, Robert B

    2017-10-17

    Quantifying the relationship between protein sequence and structure is key to understanding the protein universe. A fundamental measure of this relationship is the total number of amino acid sequences that can fold to a target protein structure, known as the "sequence capacity," which has been suggested as a proxy for how designable a given protein fold is. Although sequence capacity has been extensively studied using lattice models and theory, numerical estimates for real protein structures are currently lacking. In this work, we have quantitatively estimated the sequence capacity of 10 proteins with a variety of different structures using a statistical model based on residue-residue co-evolution to capture the variation of sequences from the same protein family. Remarkably, we find that even for the smallest protein folds, such as the WW domain, the number of foldable sequences is extremely large, exceeding the Avogadro constant. In agreement with earlier theoretical work, the calculated sequence capacity is positively correlated with the size of the protein, or better, the density of contacts. This allows the absolute sequence capacity of a given protein to be approximately predicted from its structure. On the other hand, the relative sequence capacity, i.e., normalized by the total number of possible sequences, is an extremely tiny number and is strongly anti-correlated with the protein length. Thus, although there may be more foldable sequences for larger proteins, it will be much harder to find them. Lastly, we have correlated the evolutionary age of proteins in the CATH database with their sequence capacity as predicted by our model. The results suggest a trade-off between the opposing requirements of high designability and the likelihood of a novel fold emerging by chance. Published by Elsevier Inc.

  18. The Renilla luciferase gene as a reference gene for normalization of gene expression in transiently transfected cells.

    PubMed

    Jiwaji, Meesbah; Daly, Rónán; Pansare, Kshama; McLean, Pauline; Yang, Jingli; Kolch, Walter; Pitt, Andrew R

    2010-12-31

    The importance of appropriate normalization controls in quantitative real-time polymerase chain reaction (qPCR) experiments has become more apparent as the number of biological studies using this methodology has increased. In developing a system to study gene expression from transiently transfected plasmids, it became clear that normalization using chromosomally encoded genes is not ideal, at it does not take into account the transfection efficiency and the significantly lower expression levels of the plasmids. We have developed and validated a normalization method for qPCR using a co-transfected plasmid. The best chromosomal gene for normalization in the presence of the transcriptional activators used in this study, cadmium, dexamethasone, forskolin and phorbol-12-myristate 13-acetate was first identified. qPCR data was analyzed using geNorm, Normfinder and BestKeeper. Each software application was found to rank the normalization controls differently with no clear correlation. Including a co-transfected plasmid encoding the Renilla luciferase gene (Rluc) in this analysis showed that its calculated stability was not as good as the optimised chromosomal genes, most likely as a result of the lower expression levels and transfection variability. Finally, we validated these analyses by testing two chromosomal genes (B2M and ActB) and a co-transfected gene (Rluc) under biological conditions. When analyzing co-transfected plasmids, Rluc normalization gave the smallest errors compared to the chromosomal reference genes. Our data demonstrates that transfected Rluc is the most appropriate normalization reference gene for transient transfection qPCR analysis; it significantly reduces the standard deviation within biological experiments as it takes into account the transfection efficiencies and has easily controllable expression levels. This improves reproducibility, data validity and most importantly, enables accurate interpretation of qPCR data.

  19. Association of MicroRNA-196a2 Variant with Response to Short-Acting β2-Agonist in COPD: An Egyptian Pilot Study

    PubMed Central

    Fawzy, Manal S.; Hussein, Mohammad H.; Abdelaziz, Eman Z.; Yamany, Hussain A.; Ismail, Hussein M.; Toraih, Eman A.

    2016-01-01

    Chronic obstructive pulmonary disease (COPD) is a multifactorial chronic respiratory disease, characterized by an obstructive pattern. Understanding the genetic predisposition of COPD is essential to develop personalized treatment regimens. MicroRNAs (miRNAs) are small, endogenous, non-coding RNAs that modulate the expression levels of specific proteins based on sequence complementarity with their target mRNA molecules. Emerging evidences demonstrated the potential use of miRNAs as a disease biomarker. This pilot study aimed to investigate the association of the MIR-196a2 rs11614913 (C/T) polymorphism with COPD susceptibility, the clinical outcome and bronchodilator response to short-acting β2-agonist. Genotyping of rs11614913 polymorphism was determined in 108 COPD male patients and 116 unrelated controls using real-time polymerase chain reaction technology. In silico target prediction and network core analysis were performed. COPD patients did not show significant differences in the genotype distribution (p = 0.415) and allele frequencies (p = 0.306) of the studied miRNA when compared with controls. There were also no associations with GOLD stage, dyspnea grade, disease exacerbations, COPD assessment test for estimating impact on health status score, or the frequency of intensive care unit admission. However, COPD patients with CC genotype corresponded to the smallest bronchodilator response after Salbutamol inhalation, the heterozygotes (CT) had an intermediate response, while those with the TT genotype showed the highest response (p < 0.001). In conclusion MIR-196a2 rs11614913 polymorphism is associated with the bronchodilator response of COPD in our sample of the Egyptian population, generating hypothesis of the potential use of MIR-196a2 variant as a pharmacogenetic marker for COPD. PMID:27043015

  20. Procedure for the Selection and Validation of a Calibration Model I-Description and Application.

    PubMed

    Desharnais, Brigitte; Camirand-Lemyre, Félix; Mireault, Pascal; Skinner, Cameron D

    2017-05-01

    Calibration model selection is required for all quantitative methods in toxicology and more broadly in bioanalysis. This typically involves selecting the equation order (quadratic or linear) and weighting factor correctly modelizing the data. A mis-selection of the calibration model will generate lower quality control (QC) accuracy, with an error up to 154%. Unfortunately, simple tools to perform this selection and tests to validate the resulting model are lacking. We present a stepwise, analyst-independent scheme for selection and validation of calibration models. The success rate of this scheme is on average 40% higher than a traditional "fit and check the QCs accuracy" method of selecting the calibration model. Moreover, the process was completely automated through a script (available in Supplemental Data 3) running in RStudio (free, open-source software). The need for weighting was assessed through an F-test using the variances of the upper limit of quantification and lower limit of quantification replicate measurements. When weighting was required, the choice between 1/x and 1/x2 was determined by calculating which option generated the smallest spread of weighted normalized variances. Finally, model order was selected through a partial F-test. The chosen calibration model was validated through Cramer-von Mises or Kolmogorov-Smirnov normality testing of the standardized residuals. Performance of the different tests was assessed using 50 simulated data sets per possible calibration model (e.g., linear-no weight, quadratic-no weight, linear-1/x, etc.). This first of two papers describes the tests, procedures and outcomes of the developed procedure using real LC-MS-MS results for the quantification of cocaine and naltrexone. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Accuracy of unmodified Stokes' integration in the R-C-R procedure for geoid computation

    NASA Astrophysics Data System (ADS)

    Ismail, Zahra; Jamet, Olivier

    2015-06-01

    Geoid determinations by the Remove-Compute-­Restore (R-C-R) technique involves the application of Stokes' integral on reduced gravity anomalies. Numerical Stokes' integration produces an error depending on the choice of the integration radius, grid resolution and Stokes' kernel function. In this work, we aim to evaluate the accuracy of Stokes' integral through a study on synthetic gravitational signals derived from EGM2008 on three different landscape areas with respect to the size of the integration domain and the resolution of the anomaly grid. The influence of the integration radius was studied earlier by several authors. Using real data, they found that the choice of relatively small radii (less than 1°) enables to reach an optimal accuracy. We observe a general behaviour coherent with these earlier studies. On the other hand, we notice that increasing the integration radius up to 2° or 2.5° might bring significantly better results. We note that, unlike the smallest radius corresponding to a local minimum of the error curve, the optimal radius in the range 0° to 6° depends on the terrain characteristics. We also find that the high frequencies, from degree 600, improve continuously with the integration radius in both semi-­mountainous and mountain areas. Finally, we note that the relative error of the computed geoid heights depends weakly on the anomaly spherical harmonic degree in the range from degree 200 to 2000. It remains greater than 10 % for any integration radii up to 6°. This result tends to prove that a one centimetre accuracy cannot be reached in semi-mountainous and mountainous regions with the unmodified Stokes' kernel.

  2. Pre-clinical laboratory evaluation of the new 'AF' arterial line filter range.

    PubMed

    Yarham, Gemma; Mulholland, John

    2010-07-01

    The presence of emboli was recognised relatively early in the history of open heart surgery. The emboli produced during cardiopulmonary bypass have the predisposition to distribute into, and ultimately obstruct, microvessels of all tissues. The Sorin Group has recently developed a new range of arterial line filters. Before the Sorin AF range of filters was released for pre-launch clinical trials, our group performed in vitro laboratory testing of the AF range against a selection of commercially available filters on the global market. The Sorin AF620 and AF640 demonstrate both the smallest prime volume and smallest surface contact area (92ml and 290 cm(2), respectively).The results of the GME Handling Efficiency experiments ranged by 39.6%, from 95.9% to 56.3%. In terms of an air bolus handling, the results of the Limit Bolus experiment ranged by 97 ml, from 147.5 ml down to 50 ml. The pressure drop across all the filters was measured under steady state experimental conditions. All of the above investigations were considered against surface area and prime volume. It is clear from the results that some commercially available arterial line filters perform better than others, not only in overall performance, but also with regard to individual characteristics. Evaluating arterial line filters for hospital-specific use has to balance pressure drop, surface area, micro air handling, prime volume and gross air handling; all points need to be considered. In the AF620 and AF640, Sorin boast that they are the two smallest prime and smallest surface area filters commercially available on the global market. The Sorin AF filter range performs well in all of the areas we investigated and will be a competitive option for centres, irrespective of which characteristics they use to evaluate and select their arterial line filter.

  3. Cause-specific sickness absence trends by occupational class and industrial sector in the context of recent labour market changes: a Finnish panel data study.

    PubMed

    Leinonen, Taina; Viikari-Juntura, Eira; Husgafvel-Pursiainen, Kirsti; Solovieva, Svetlana

    2018-04-07

    We aimed to provide previously unestablished information on population-based differences in cause-specific sickness absence trends between occupational classes and further between four large industrial sectors within the different occupational classes while controlling for other socioeconomic factors and employment patterns. We focused on the period 2005-2013, during which the labour market underwent large economic and structural changes in many countries. Register-based panel data study. Large representative datasets on Finnish wage earners aged 25-59 years. Annual risk of sickness absence (>10 working days) based on repeated logistic regression. Between 2005 and 2013, the proportion of employees with sickness absence decreased. Occupational class differences in sickness absence trends varied by disease group. Overall, the decrease in absences was smallest among lower non-manual employees. Sickness absence levels were highest in the health and social work sector and in the manufacturing sector within the non-manual and manual classes, respectively. Absences due to musculoskeletal diseases decreased temporarily during the peak of the economic recession in 2009, particularly in the manufacturing sector within the manual class. The decrease in absences due to musculoskeletal diseases was smallest in the trade sector within the lower occupational classes. Overall, education, income and employment patterns partly explained the differences in the absence levels, but not in the trends. We found a complex interplay between the associations of occupational class and industrial sector with sickness absence trends. During the economic recession, absences due to musculoskeletal diseases decreased temporarily in a segment of wage earners who were known to have been hit hard by the recession. However, the trend differences were not explained by the measured structural changes in the characteristics of the study population. Both occupational class and industrial sector should be taken into account when tackling problems of work disability. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  4. Correlations between community size and student perceptions of value.

    PubMed

    Anderson, Susan M; Simanton, Edward

    2017-01-01

    The purpose of this study was to determine if medical students' feeling of being valued was correlated to community size. The study, conducted in several communities in South Dakota, examined students' feeling of value relating to attending physicians, healthcare teams and patients. Student value items were added to student satisfaction surveys sent out to students at the end of their primary clinical year and data collected from two graduating classes of students (n=114). Student responses were grouped by clinical campus and mean responses by community size were calculated. Additionally, student encounter logs were reviewed for study participants to gauge participation levels during clinical encounters. The degree to which students felt valued by their physician attending, the healthcare team and the patients decreased consistently as community size increased. Differences were statistically significant between students in the smallest and largest communities. Additionally, students in the community of 15 000 felt significantly more valued than students in the community of 170 000. Furthermore, there also appears to be a relationship between the percentage of participation in patient care by students and community size. Students in the smaller, rural communities participated at a higher percentage rather than observing. There appears to be a relationship between community size and the extent to which students feel value. The degree to which students felt valued decreased consistently as community size increased. Differences were statistically significant between students in the smallest communities and the two largest communities. Students in the smaller, rural communities participated at a higher percentage. Additional studies are needed to address whether students participate more as a result of feeling valued, or whether participation leads to an enhanced perception of value by students.

  5. Reliability and Validity of a New Test of Agility and Skill for Female Amateur Soccer Players

    PubMed Central

    Kutlu, Mehmet; Yapici, Hakan; Yilmaz, Abdullah

    2017-01-01

    Abstract The aim of this study was to evaluate the Agility and Skill Test, which had been recently developed to assess agility and skill in female athletes. Following a 10 min warm-up, two trials to test the reliability and validity of the test were conducted one week apart. Measurements were collected to compare soccer players’ physical performance in a 20 m sprint, a T-Drill test, the Illinois Agility Run Test, change-of-direction and acceleration, as well as agility and skill. All tests were completed following the same order. Thirty-four amateur female soccer players were recruited (age = 20.8 ± 1.9 years; body height = 166 ± 6.9 cm; body mass = 55.5 ± 5.8 kg). To determine the reliability and usefulness of these tests, paired sample t-tests, intra-class correlation coefficients, typical error, coefficient of variation, and differences between the typical error and smallest worthwhile change statistics were computed. Test results showed no significant differences between the two sessions (p > 0.01). There were higher intra-class correlations between the test and retest values (r = 0.94–0.99) for all tests. Typical error values were below the smallest worthwhile change, indicating ‘good’ usefulness for these tests. A near perfect Pearson correlation between the Agility and Skill Test (r = 0.98) was found, and there were moderate-to-large levels of correlation between the Agility and Skill Test and other measures (r = 0.37 to r = 0.56). The results of this study suggest that the Agility and Skill Test is a reliable and valid test for female soccer players and has significant value for assessing the integrative agility and skill capability of soccer players. PMID:28469760

  6. The Complete Mitochondrial Genome of Corizus tetraspilus (Hemiptera: Rhopalidae) and Phylogenetic Analysis of Pentatomomorpha

    PubMed Central

    Guo, Zhong-Long; Wang, Juan; Shen, Yu-Ying

    2015-01-01

    Insect mitochondrial genome (mitogenome) are the most extensively used genetic information for molecular evolution, phylogenetics and population genetics. Pentatomomorpha (>14,000 species) is the second largest infraorder of Heteroptera and of great economic importance. To better understand the diversity and phylogeny within Pentatomomorpha, we sequenced and annotated the complete mitogenome of Corizus tetraspilus (Hemiptera: Rhopalidae), an important pest of alfalfa in China. We analyzed the main features of the C. tetraspilus mitogenome, and provided a comparative analysis with four other Coreoidea species. Our results reveal that gene content, gene arrangement, nucleotide composition, codon usage, rRNA structures and sequences of mitochondrial transcription termination factor are conserved in Coreoidea. Comparative analysis shows that different protein-coding genes have been subject to different evolutionary rates correlated with the G+C content. All the transfer RNA genes found in Coreoidea have the typical clover leaf secondary structure, except for trnS1 (AGN) which lacks the dihydrouridine (DHU) arm and possesses a unusual anticodon stem (9 bp vs. the normal 5 bp). The control regions (CRs) among Coreoidea are highly variable in size, of which the CR of C. tetraspilus is the smallest (440 bp), making the C. tetraspilus mitogenome the smallest (14,989 bp) within all completely sequenced Coreoidea mitogenomes. No conserved motifs are found in the CRs of Coreoidea. In addition, the A+T content (60.68%) of the CR of C. tetraspilus is much lower than that of the entire mitogenome (74.88%), and is lowest among Coreoidea. Phylogenetic analyses based on mitogenomic data support the monophyly of each superfamily within Pentatomomorpha, and recognize a phylogenetic relationship of (Aradoidea + (Pentatomoidea + (Lygaeoidea + (Pyrrhocoroidea + Coreoidea)))). PMID:26042898

  7. Variation in chilling tolerance for photosynthesis and leaf extension growth among genotypes related to the C-4 grass Miscanthus xgiganteus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glowacka, K; Adhikari, S; Peng, JH

    The goal of this study was to identify cold-tolerant genotypes within two species of Miscanthus related to the exceptionally chilling-tolerant C-4 biomass crop accession: M. xgiganteus 'Illinois' (Mxg) as well as in other Mxg genotypes. The ratio of leaf elongation at 10 degrees C/5 degrees C to that at 25 degrees C/25 degrees C was used to identify initially the 13 most promising Miscanthus genotypes out of 51 studied. Net leaf CO2 uptake (A(sat)) and the maximum operating efficiency of photosystem II (Phi(PSII)) were measured in warm conditions (25 degrees C/20 degrees C), and then during and following a chillingmore » treatment of 10 degrees C/5 degrees C for 11 d. Accessions of M. sacchariflorus (Msa) showed the smallest decline in leaf elongation on transfer to chilling conditions and did not differ significantly from Mxg, indicating greater chilling tolerance than diploid M. sinensis (Msi). Msa also showed the smallest reductions in A(sat) and Phi(PSII), and greater chilling-tolerant photosynthesis than Msi, and three other forms of Mxg, including new triploid accessions and a hexaploid Mxg 'Illinois'. Tetraploid Msa 'PF30153' collected in Gifu Prefecture in Honshu, Japan did not differ significantly from Mxg 'Illinois' in leaf elongation and photosynthesis at low temperature, but was significantly superior to all other forms of Mxg tested. The results suggested that the exceptional chilling tolerance of Mxg 'Illinois' cannot be explained simply by the hybrid vigour of this intraspecific allotriploid. Selection of chilling-tolerant accessions from both of Mxg's parental species, Msi and Msa, would be advisable for breeding new highly chilling-tolerant Mxg genotypes.« less

  8. Time loss injuries compromise team success in Elite Rugby Union: a 7-year prospective study.

    PubMed

    Williams, Sean; Trewartha, Grant; Kemp, Simon P T; Brooks, John H M; Fuller, Colin W; Taylor, Aileen E; Cross, Matthew J; Stokes, Keith A

    2016-06-01

    A negative association between injuries and team success has been demonstrated in professional football, but the nature of this association in elite Rugby Union teams is currently unclear. To assess the association between injury burden measures and team success outcomes within professional Rugby Union teams. A seven-season prospective cohort design was used to record all time-loss injuries incurred by English Premiership players. Associations between team success measures (league points tally and Eurorugby Club Ranking (ECR)) and injury measures (injury burden and injury days per team-match) were modelled, both within (changes from season to season) and between (differences averaged over all seasons) teams. Thresholds for the smallest worthwhile change in league points tally and ECR were 3 points and 2.6%, respectively. Data from a total of 1462 players within 15 Premiership teams were included in the analysis. We found clear negative associations between injury measures and team success (70-100% likelihood), with the exception of between-team differences for injury days per team-match and ECR, which was unclear. A reduction in injury burden of 42 days (90% CI 30 to 70) per 1000 player hours (22% of mean injury burden) was associated with the smallest worthwhile change in league points tally. Clear negative associations were found between injury measures and team success, and moderate reductions in injury burden may have worthwhile effects on competition outcomes for professional Rugby Union teams. These findings may be useful when communicating the value of injury prevention initiatives within this elite sport setting. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  9. Lumen and calcium characteristics within calcified coronary lesions. Comparison of computed tomography coronary angiography versus intravascular ultrasound.

    PubMed

    Noll, Dariusz; Kruk, Mariusz; Pręgowski, Jerzy; Kaczmarska, Edyta; Kryczka, Karolina; Pracoń, Radosław; Skwarek, Mirosław; Dzielińska, Zofia; Petryka, Joanna; Spiewak, Mateusz; Lubiszewska, Barbara; Norwa-Otto, Bożena; Opolski, Maksymilian; Witkowski, Adam; Demkow, Marcin; Rużyłło, Witold; Kępka, Cezary

    2013-01-01

    Computed tomography coronary angiography (CTCA) is a diagnostic method used for exclusion of coronary artery disease. However, lower accuracy of CTCA in assessment of calcified lesions is a significant factor impeding applicability of CTCA for assessment of coronary atherosclerosis. To provide insight into lumen and calcium characteristics assessed with CTCA, we compared these parameters to the reference of intravascular ultrasound (IVUS). Two hundred and fifty-two calcified lesions within 97 arteries of 60 patients (19 women, age 63 ±10 years) underwent assessment with both 2 × 64 slice CT (Somatom Definition, Siemens) and IVUS (s5, Volcano Corp.). Coronary lumen and calcium dimensions within calcified lesions were assessed with CTCA and compared to the reference measurements made with IVUS. On average CTCA underestimated mean lumen diameter (2.8 ±0.7 mm vs. 2.9 ±0.8 mm for IVUS), lumen area (6.4 ±3.4 mm(2) vs. 7.0 ±3.7 mm(2) for IVUS, p < 0.001) and total calcium arc (52 ±35° vs. 83 ±54°). However, analysis of tertiles of the examined parameters revealed that the mean lumen diameter, lumen area and calcium arc did not significantly differ between CTCA and IVUS within the smallest lumens (1(st) tertile of mean lumen diameter at 2.1 mm, and 1(st) tertile of lumen area at 3.7 mm(2)) and lowest calcium arc (mean of 40°). Although, on average, CTCA underestimates lumen diameter and area as well as calcium arc within calcified lesions, the differences are not significant within the smallest vessels and calcium arcs. The low diagnostic accuracy of CTCA within calcified lesions may be attributed to high variance and not to systematic error of measurements.

  10. The Vocal Cord Dysfunction Questionnaire: Validity and Reliability of the Persian Version.

    PubMed

    Ghaemi, Hamide; Khoddami, Seyyedeh Maryam; Soleymani, Zahra; Zandieh, Fariborz; Jalaie, Shohreh; Ahanchian, Hamid; Khadivi, Ehsan

    2017-12-25

    The aim of this study was to develop, validate, and assess the reliability of the Persian version of Vocal Cord Dysfunction Questionnaire (VCDQ P ). The study design was cross-sectional or cultural survey. Forty-four patients with vocal fold dysfunction (VFD) and 40 healthy volunteers were recruited for the study. To assess the content validity, the prefinal questions were given to 15 experts to comment on its essential. Ten patients with VFD rated the importance of VCDQ P in detecting face validity. Eighteen of the patients with VFD completed the VCDQ 1 week later for test-retest reliability. To detect absolute reliability, standard error of measurement and smallest detected change were calculated. Concurrent validity was assessed by completing the Persian Chronic Obstructive Pulmonary Disease (COPD) Assessment Test (CAT) by 34 patients with VFD. Discriminant validity was measured from 34 participants. The VCDQ was further validated by administering the questionnaire to 40 healthy volunteers. Validation of the VCDQ as a treatment outcome tool was conducted in 18 patients with VFD using pre- and posttreatment scores. The internal consistency was confirmed (Cronbach α = 0.78). The test-retest reliability was excellent (intraclass correlation coefficient = 0.97). The standard error of measurement and smallest detected change values were acceptable (0.39 and 1.08, respectively). There was a significant correlation between the VCDQ P and the CAT total scores (P < 0.05). Discriminative validity was significantly different. The VCDQ scores in patients with VFD before and after treatment was significantly different (P < 0.001). The VCDQ was cross-culturally adapted to Persian and demonstrated to be a valid and reliable self-administered questionnaire in Persian-speaking population. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  11. Deriving the real-ear SPL of audiometric data using the "coupler to dial difference" and the "real ear to coupler difference".

    PubMed

    Munro, K J; Davis, J

    2003-04-01

    The purpose of the study was to compare the measured real-ear sound pressure level (SPL) of audiometer output with the derived real-ear SPL obtained by adding the coupler to dial difference (CDD) and real-ear to coupler difference (RECD) to the audiometer dial reading. The real-ear SPL and RECD were measured in one ear of 16 normally hearing subjects using a probe-tube microphone. The CDD transform and the RECD transfer function were measured in an HA1 and an HA2 2-cc coupler using an EAR-LINK foam ear-tip or a customized earmold. The RECD transfer function was measured using the EARTone ER 3A and the Audioscan RE770 insert earphone. The procedures were very reliable with mean differences on retest of less than 1 dB. The mean difference between the measured and derived real-ear SPL was generally less than 1 dB and rarely exceeded 3 dB in any subject. The CDD measured for an individual audiometer and the RECD measured for an individual ear can be used to derive a valid estimate of real-ear SPL when it has not been possible to measure this directly.

  12. A Geographic Simulation Model for the Treatment of Trauma Patients in Disasters.

    PubMed

    Carr, Brendan G; Walsh, Lauren; Williams, Justin C; Pryor, John P; Branas, Charles C

    2016-08-01

    Though the US civilian trauma care system plays a critical role in disaster response, there is currently no systems-based strategy that enables hospital emergency management and local and regional emergency planners to quantify, and potentially prepare for, surges in trauma care demand that accompany mass-casualty disasters. A proof-of-concept model that estimates the geographic distributions of patients, trauma center resource usage, and mortality rates for varying disaster sizes, in and around the 25 largest US cities, is presented. The model was designed to be scalable, and its inputs can be modified depending on the planning assumptions of different locales and for different types of mass-casualty events. To demonstrate the model's potential application to real-life planning scenarios, sample disaster responses for 25 major US cities were investigated using a hybrid of geographic information systems and dynamic simulation-optimization. In each city, a simulated, fast-onset disaster epicenter, such as might occur with a bombing, was located randomly within one mile of its population center. Patients then were assigned and transported, in simulation, via the new model to Level 1, 2, and 3 trauma centers, in and around each city, over a 48-hour period for disaster scenario sizes of 100, 500, 5000, and 10,000 casualties. Across all 25 cities, total mean mortality rates ranged from 26.3% in the smallest disaster scenario to 41.9% in the largest. Out-of-hospital mortality rates increased (from 21.3% to 38.5%) while in-hospital mortality rates decreased (from 5.0% to 3.4%) as disaster scenario sizes increased. The mean number of trauma centers involved ranged from 3.0 in the smallest disaster scenario to 63.4 in the largest. Cities that were less geographically isolated with more concentrated trauma centers in their surrounding regions had lower total and out-of-hospital mortality rates. The nine US cities listed as being the most likely targets of terrorist attacks involved, on average, more trauma centers and had lower mortality rates compared with the remaining 16 cities. The disaster response simulation model discussed here may offer insights to emergency planners and health systems in more realistically planning for mass-casualty events. Longer wait and transport times needed to distribute high numbers of patients to distant trauma centers in fast-onset disasters may create predictable increases in mortality and trauma center resource consumption. The results of the modeled scenarios indicate the need for a systems-based approach to trauma care management during disasters, since the local trauma center network was often too small to provide adequate care for the projected patient surge. Simulation of out-of-hospital resources that might be called upon during disasters, as well as guidance in the appropriate execution of mutual aid agreements and prevention of over-response, could be of value to preparedness planners and emergency response leaders. Study assumptions and limitations are discussed. Carr BG , Walsh L , Williams JC , Pryor JP , Branas CC . A geographic simulation model for the treatment of trauma patients in disasters. Prehosp Disaster Med. 2016;31(4):413-421.

  13. Method Development for Container Closure Integrity Evaluation via Headspace Gas Ingress by Using Frequency Modulation Spectroscopy.

    PubMed

    Victor, Ken G; Levac, Lauren; Timmins, Michael; Veale, James

    2017-01-01

    USP <1207.1> Section 3.5 states that "A deterministic leak test method having the ability to detect leaks at the product's maximum allowable leakage limit is preferred when establishing the inherent integrity of a container-closure system." Ideally, container closure integrity of parenteral packaging would be evaluated by measuring a physical property that is sensitive to the presence of any package defect that breaches package integrity by increasing its leakage above its maximum allowable leakage limit. The primary goals of the work presented herein were to demonstrate the viability of the nondestructive, deterministic method known as laser-based gas headspace analysis for evaluating container closure integrity and to provide a physical model for predicting leak rates for a variety of container volumes, headspace conditions, and defect sizes. The results demonstrate that laser-based headspace analysis provides sensitive, accurate, and reproducible measurements of the gas ingress into glass vial-stopper package assemblies that are under either diffusive or effusive leak conditions. Two different types of positive controls were examined. First, laser-drilled micro-holes in thin metal disks that were crimped on top of 15R glass vials served as positive controls with a well-characterized defect geometry. For these, a strong correlation was observed between the measured ingress parameter and the size of the defect for both diffusive and effusive conditions. Second, laser-drilled holes in the wall of glass vials served as controls that more closely simulate real-world defects. Due to their complex defect geometries, their diffusive and effusive ingress parameters did not necessarily correlate; this is an important observation that has significant implications for standardizing the characterization of container defects. Regardless, laser-based headspace analysis could readily differentiate positive and negative controls for all leak conditions, and the results provide a guide for method development of container closure integrity tests. LAY ABSTRACT: The new USP 39 <1207>, "Package Integrity Evaluation-Sterile Products", states in section 3.4.1: "tracer gas tests performed using … laser-based gas headspace analysis [have] been shown to be sensitive enough to quantitatively analyze leakage through the smallest leak paths found to pose the smallest chance of liquid leakage or microbial ingress in rigid packaging." In addition, USP <1207> also states that "for such methods, the limit of detection can be mathematically predicted on the basis of gas flow kinetics." Using the above statements as a foundation, this paper presents a theoretical basis for predicting the gas ingress through well-defined defects in product vials sealed under a variety of headspace conditions. These calculated predictions were experimentally validated by comparing them to measurements of changes in the headspace oxygen content or total pressure for several different positive controls using laser-based headspace analysis. The results demonstrated that laser-based headspace analysis can, by readily differentiating between negative controls and positive controls with a range of defect sizes on the micron scale, be used to assess container closure integrity. The work also demontrated that caution must be used when attempting to correlate a leak rate to an idealized defect-size parameter. © PDA, Inc. 2017.

  14. Optimization of batteries for plug-in hybrid electric vehicles

    NASA Astrophysics Data System (ADS)

    English, Jeffrey Robb

    This thesis presents a method to quickly determine the optimal battery for an electric vehicle given a set of vehicle characteristics and desired performance metrics. The model is based on four independent design variables: cell count, cell capacity, state-of-charge window, and battery chemistry. Performance is measured in seven categories: cost, all-electric range, maximum speed, acceleration, battery lifetime, lifetime greenhouse gas emissions, and charging time. The performance of each battery is weighted according to a user-defined objective function to determine its overall fitness. The model is informed by a series of battery tests performed on scaled-down battery samples. Seven battery chemistries were tested for capacity at different discharge rates, maximum output power at different charge levels, and performance in a real-world automotive duty cycle. The results of these tests enable a prediction of the performance of the battery in an automobile. Testing was performed at both room temperature and low temperature to investigate the effects of battery temperature on operation. The testing highlighted differences in behavior between lithium, nickel, and lead based batteries. Battery performance decreased with temperature across all samples with the largest effect on nickel-based chemistries. Output power also decreased with lead acid batteries being the least affected by temperature. Lithium-ion batteries were found to be highly efficient (>95%) under a vehicular duty cycle; nickel and lead batteries have greater losses. Low temperatures hindered battery performance and resulted in accelerated failure in several samples. Lead acid, lead tin, and lithium nickel alloy batteries were unable to complete the low temperature testing regime without losing significant capacity and power capability. This is a concern for their applicability in electric vehicles intended for cold climates which have to maintain battery temperature during long periods of inactivity. Three sample optimizations were performed: a compact car, a, truck, and a sports car. The compact car benefits from increased battery capacity despite the associated higher cost. The truck returned the smallest possible battery of each chemistry, indicating that electrification is not advisable. The sports car optimization resulted in the largest possible battery, indicating large performance from increased electrification. These results mirror the current state of the electric vehicle market.

  15. Inter-laboratory Comparison of Three Earplug Fit-test Systems

    PubMed Central

    Byrne, David C.; Murphy, William J.; Krieg, Edward F.; Ghent, Robert M.; Michael, Kevin L.; Stefanson, Earl W.; Ahroon, William A.

    2017-01-01

    The National Institute for Occupational Safety and Health (NIOSH) sponsored tests of three earplug fit-test systems (NIOSH HPD Well-Fit™, Michael & Associates FitCheck, and Honeywell Safety Products VeriPRO®). Each system was compared to laboratory-based real-ear attenuation at threshold (REAT) measurements in a sound field according to ANSI/ASA S12.6-2008 at the NIOSH, Honeywell Safety Products, and Michael & Associates testing laboratories. An identical study was conducted independently at the U.S. Army Aeromedical Research Laboratory (USAARL), which provided their data for inclusion in this report. The Howard Leight Airsoft premolded earplug was tested with twenty subjects at each of the four participating laboratories. The occluded fit of the earplug was maintained during testing with a soundfield-based laboratory REAT system as well as all three headphone-based fit-test systems. The Michael & Associates lab had highest average A-weighted attenuations and smallest standard deviations. The NIOSH lab had the lowest average attenuations and the largest standard deviations. Differences in octave-band attenuations between each fit-test system and the American National Standards Institute (ANSI) sound field method were calculated (Attenfit-test - AttenANSI). A-weighted attenuations measured with FitCheck and HPD Well-Fit systems demonstrated approximately ±2 dB agreement with the ANSI sound field method, but A-weighted attenuations measured with the VeriPRO system underestimated the ANSI laboratory attenuations. For each of the fit-test systems, the average A-weighted attenuation across the four laboratories was not significantly greater than the average of the ANSI sound field method. Standard deviations for residual attenuation differences were about ±2 dB for FitCheck and HPD Well-Fit compared to ±4 dB for VeriPRO. Individual labs exhibited a range of agreement from less than a dB to as much as 9.4 dB difference with ANSI and REAT estimates. Factors such as the experience of study participants and test administrators, and the fit-test psychometric tasks are suggested as possible contributors to the observed results. PMID:27786602

  16. The association between gas and galaxies - II. The two-point correlation function

    NASA Astrophysics Data System (ADS)

    Wilman, R. J.; Morris, S. L.; Jannuzi, B. T.; Davé, R.; Shone, A. M.

    2007-02-01

    We measure the two-point correlation function, ξAG, between galaxies and quasar absorption-line systems at z < 1, using the data set of Morris & Jannuzi on 16 lines-of-sight (LOS) with ultraviolet (UV) spectroscopy and galaxy multi-object spectroscopy (Paper I). The measurements are made in 2D redshift space out to π = 20h-1 Mpc (comoving) along the LOS and out to σ = 2h-1 Mpc projected; as a function of HI column density in the range NHI = 1013-1019cm-2, also for CIV absorption systems, and as a function of galaxy spectral type. This extends the absorber-galaxy pair analysis of Paper I. We find that the amplitude of the peak in ξAG at the smallest separations increases slowly as the lower limit on NHI is increased from 1013 to 1016cm-2, and then jumps sharply (albeit with substantial uncertainties) for NHI > 1017cm-2. For CIV absorbers, the peak strength of ξAG is roughly comparable to that of HI absorbers with NHI > 1016.5cm-2, consistent with the finding that the CIV absorbers are associated with strong HI absorbers. We do not reproduce the differences reported by Chen et al. between 1D ξAG measurements using galaxy subsamples of different spectral types. However, the full impact on the measurements of systematic differences in our samples is hard to quantify. We compare the observations with smoothed particle hydrodynamical (SPH) simulations and discover that in the observations ξAG is more concentrated to the smallest separations than in the simulations. The latter also display a `finger of god' elongation of ξAG along the LOS in redshift space, which is absent from our data, but similar to that found by Ryan-Weber for the cross-correlation of quasar absorbers and HI-emission-selected galaxies. The physical origin of these `fingers of god' is unclear, and we thus highlight several possible areas for further investigation.

  17. Synthesizing the Nanocrytalline Cobalt-Iron Coating Through The Electrodeposition Process With Different Time Deposition

    NASA Astrophysics Data System (ADS)

    Rozlin Nik Masdek, Nik; Sorfian Hafiz Mansor, Mohd; Salleh, Zuraidah; Hyie, Koay Mei

    2018-03-01

    In the engineering world, electrodeposition or electroplating has become the most popular method of surface coating in improving corrosion behavior and mechanical properties of material. Therefore in this study, CoFe nanoparticle protective coating has been synthesized on the mild steel washer using electrodeposition method. The electrodeposition was conducted in the acidic environment with the pH value range from 1 to 2 with the controlled temperature of 50°C. The influence of deposition time (30, 60, 90 minutes) towards characteristic and properties such as particle size, surface morphology, corrosion behavior, and microhardness were studied in this investigation. Several results can be obtained by doing this experiment and testing. First, the surface morphology of Cobalt Iron (CoFe) on the electrodeposited mild steel washer are obtained. In addition, the microhardness of the mild steel washer due to the different deposition time are determined. Next, the observation on the difference in the grain size of CoFe that has been electrodeposited on the mild steel plate is made. Last but not least, the corrosion behavior was investigated. CoFe nanoparticles deposited for 30 minutes produced the smallest particle size and the highest microhardness of 86.17 and 236.84 HV respectively. The CoFe nanoparticles also exhibit the slowest corrosion rate at 30 minutes as compared to others. The crystalline size also increases when the time deposition is increased. The sample with 30 minute depositon time indicate the smallest crystalline size which is 15nm. The decrement of deposition time plays an important role in synthesizing CoFe nanoparticles with good corrosion resistance and microhardness. CoFe nanoparticles obtained at 30 minutes shows high corrosion resistance compared to others. In a nutshell, it was observed that the decrement of deposition time improved mechanical and corrosion properties of CoFe nanoparticles.

  18. Task-induced Changes in Idiopathic Infantile Nystagmus Vary with Gaze.

    PubMed

    Salehi Fadardi, Marzieh; Bathke, Arne C; Harrar, Solomon W; Abel, Larry Allen

    2017-05-01

    Investigations of infantile nystagmus syndrome (INS) at center or at the null position have reported that INS worsens when visual demand is combined with internal states, e.g. stress. Visual function and INS parameters such as foveation time, frequency, amplitude, and intensity can also be influenced by gaze position. We hypothesized that increases from baseline in visual demand and mental load would affect INS parameters at the null position differently than at other gaze positions. Eleven participants with idiopathic INS were asked to determine the direction of Tumbling-E targets, whose visual demand was varied through changes in size and contrast, using a staircase procedure. Targets appeared between ±25° in 5° steps. The task was repeated with both mental arithmetic and time restriction to impose higher mental load, confirmed through subjective ratings and concurrent physiological measurements. Within-subject comparisons were limited to the null and 15° away from it. No significant main effects of task on any INS parameters were found. At both locations, high mental load worsened task performance metrics, i.e. lowest contrast (P = .001) and smallest optotype size reached (P = .012). There was a significant interaction between mental load and gaze position for foveation time (P = .02) and for the smallest optotype reached (P = .028). The increase in threshold optotype size from the low to high mental load was greater at the null than away from it. During high visual demand, foveation time significantly decreased from baseline at the null as compared to away from it (mean difference ± SE: 14.19 ± 0.7 msec; P = .010). Under high visual demand, the effects of increased mental load on foveation time and visual task performance differed at the null as compared to 15° away from it. Assessment of these effects could be valuable when evaluating INS clinically and when considering its impact on patients' daily activities.

  19. Recommendations for dose calculations of lung cancer treatment plans treated with stereotactic ablative body radiotherapy (SABR)

    NASA Astrophysics Data System (ADS)

    Devpura, S.; Siddiqui, M. S.; Chen, D.; Liu, D.; Li, H.; Kumar, S.; Gordon, J.; Ajlouni, M.; Movsas, B.; Chetty, I. J.

    2014-03-01

    The purpose of this study was to systematically evaluate dose distributions computed with 5 different dose algorithms for patients with lung cancers treated using stereotactic ablative body radiotherapy (SABR). Treatment plans for 133 lung cancer patients, initially computed with a 1D-pencil beam (equivalent-path-length, EPL-1D) algorithm, were recalculated with 4 other algorithms commissioned for treatment planning, including 3-D pencil-beam (EPL-3D), anisotropic analytical algorithm (AAA), collapsed cone convolution superposition (CCC), and Monte Carlo (MC). The plan prescription dose was 48 Gy in 4 fractions normalized to the 95% isodose line. Tumors were classified according to location: peripheral tumors surrounded by lung (lung-island, N=39), peripheral tumors attached to the rib-cage or chest wall (lung-wall, N=44), and centrally-located tumors (lung-central, N=50). Relative to the EPL-1D algorithm, PTV D95 and mean dose values computed with the other 4 algorithms were lowest for "lung-island" tumors with smallest field sizes (3-5 cm). On the other hand, the smallest differences were noted for lung-central tumors treated with largest field widths (7-10 cm). Amongst all locations, dose distribution differences were most strongly correlated with tumor size for lung-island tumors. For most cases, convolution/superposition and MC algorithms were in good agreement. Mean lung dose (MLD) values computed with the EPL-1D algorithm were highly correlated with that of the other algorithms (correlation coefficient =0.99). The MLD values were found to be ~10% lower for small lung-island tumors with the model-based (conv/superposition and MC) vs. the correction-based (pencil-beam) algorithms with the model-based algorithms predicting greater low dose spread within the lungs. This study suggests that pencil beam algorithms should be avoided for lung SABR planning. For the most challenging cases, small tumors surrounded entirely by lung tissue (lung-island type), a Monte-Carlo-based algorithm may be warranted.

  20. Assessment of upper-limb capacity, performance, and developmental disregard in children with cerebral palsy: validity and reliability of the revised Video-Observation Aarts and Aarts module: Determine Developmental Disregard (VOAA-DDD-R).

    PubMed

    Houwink, Annemieke; Geerdink, Yvonne A; Steenbergen, Bert; Geurts, Alexander C H; Aarts, Pauline B M

    2013-01-01

    To investigate the validity and reliability of the revised Video-Observation Aarts and Aarts module: Determine Developmental Disregard (VOAA-DDD-R). Upper-limb capacity and performance were assessed in children with unilateral spastic cerebral palsy (CP) by measuring overall duration of affected upper-limb use and the frequency of specific behaviours during a task in which bimanual activity was demanded ('stringing beads') and stimulated ('decorating a muffin'). Developmental disregard was defined as the difference in duration of affected upper-limb use between both tasks. Raters were two occupational and one physical therapist who received 3 hours of training. Construct validity was determined by comparing children with CP with typically developing children. Intrarater, interrater, and test-retest reliability were determined using the intraclass correlation coefficient. Standard errors of measurement and smallest detectable differences were also calculated. Twenty-five children with CP (15 females, 10 males; mean age 4 y 9 mo [SD 1 y 7 mo], range 2 y 9 mo-8 y; Manual Ability Classification System levels I-III) scored lower on capacity (p=0.052) and performance (p<0.001), and higher on developmental disregard (p<0.001) than 46 age- and sex-matched typically developing children (23 males; mean age 5 y 3 mo [SD 1 y 5 mo], range 2 y 6 mo-8 y). The intraclass correlation coefficients (0.79-1.00) indicated good reliability. Absolute agreement was high, standard errors of measurement ranged from 4.5 to 6.8%, and smallest detectable differences ranged from 12.5 to 19.0%. The VOAA-DDD-R can be reliably and validly used by occupational and physical therapists to assess upper-limb capacity, performance, and developmental disregard in children (2 y 6 mo-8 y) with CP. © The Authors. Developmental Medicine & Child Neurology © 2012 Mac Keith Press.

  1. SU-G-BRB-12: Polarity Effects in Small Volume Ionization Chambers in Small Fields

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arora, V; Parsai, E; Mathew, D

    2016-06-15

    Purpose: Dosimetric quantities such as the polarity correction factor (Ppol) are important parameters for determining the absorbed dose and can influence the choice of dosimeter. Ppol has been shown to depend on beam energy, chamber design, and field size. This study is to investigate the field size and detector orientation dependence of Ppol in small fields for several commercially available micro-chambers. Methods: We evaluate the Exradin A26, Exradin A16, PTW 31014, PTW 31016, and two prototype IBA CC-01 micro-chambers in both horizontal and vertical orientations. Measurements were taken at 10cm depth and 100cm SSD in a Wellhofer BluePhantom2. Measurements weremore » made at square fields of 0.6, 0.8, 1.0, 1.2, 1.4, 2.0, 2.4, 3.0, and 5.0 cm on each side using 6MV with both ± 300VDC biases. PPol was evaluated as described in TG-51, reported using −300VDC bias for Mraw. Ratios of PPol measured in the clinical field to the reference field are presented. Results: A field size dependence of Ppol was observed for all chambers, with increased variations when mounted vertically. The maximum variation observed in PPol over all chambers mounted horizontally was <1%, and occurred at different field sizes for different chambers. Vertically mounted chambers demonstrated variations as large as 3.2%, always at the smallest field sizes. Conclusion: Large variations in Ppol were observed for vertically mounted chambers compared to horizontal mountings. Horizontal mountings demonstrated a complicated relationship between polarity variation and field size, probably relating to differing details in each chambers construction. Vertically mounted chambers consistently demonstrated the largest PPol variations for the smallest field sizes. Measurements obtained with a horizontal mounting appear to not need significant polarity corrections for relative measurements, while those obtained using a vertical mounting should be corrected for variations in PPol.« less

  2. How quantization of gravity leads to a discrete space-time

    NASA Astrophysics Data System (ADS)

    't Hooft, Gerard

    2016-03-01

    The idea that the Planck length is the smallest unit of length, and the Planck time the smallest unit of time, is natural, and has been suggested many times. One can, however, also derive this more rigorously, using nothing more than the fact that black holes emit particles, according to Hawking's theory, and that these particles interact gravitationally. It is then observed that the particles, going in and out, form quantum states bouncing against the horizon. The dynamics of these microstates can be described in a partial wave expansion, but Hawking's expression for the entropy then requires a cut-off in the transverse momentum, in the form of a Brillouin zone, and this implies that these particles live on a lattice.

  3. [Finite element analysis of the stress distribution of two-piece post crown with different adhesives ].

    PubMed

    He, Lihui; Liu, Lijie; Gao, Bei; Gao, Shang; Chen, Yifu; Zhihui, Liu

    2013-08-01

    To establish three-dimensional finite element model of two-piece post crown to the mandibular first molar residual roots, and analyze the stress distribution characteristic to the residual roots with different adhesives, so as to get the best combination under different conditions. The complete mandibular first molar in vitro was selected, the crown was removed along the cemento-enamel junction, then the residual roots were scanned by CT. CT images were imported into a reverse engineering software, and the three-dimensional finite element model of the mandibular first molar residual roots was reconstructed. Titanium two-piece post crown of the mandibular first molar residual roots was produced, then was scanned by CT. The model was reconstructed and assembled by MIMICS. The stress distribution of the root canal and root section under the vertical load and lateral load with different bonding systems were analyzed. Three-dimensional finite element model of two-piece post crown to the mandibular first molar residual roots was established. With the increasing of elastic modulus of the adhesives, the maximum stress within the root canal was also increasing. Elastic modulus of zinc phosphate was the biggest, so the stress within the root canal was the biggest; elastic modulus of Superbond C&B was the smallest, so the stress within the root canal was the smallest. Lateral loading stress was much larger than the vertical load. Under vertical load, the load on the root section was even with different bonding systems. Under lateral load, the maximum stress was much larger than the vertical load. The stress on the root section was minimum using zinc phosphate binder, and the stress on the root section was maximum using Superbond C&B. In two-piece post crown restorations, there is significant difference between different adhesives on tooth protection. When the tooth structure of the root canal orifices is weak, in order to avoid the occurrence of splitting, the larger elastic modulus bonding system is the first choice, such as zinc phosphate binder. When the resistance form of the root canal orifices is good enough but the root is too weak, it is suggested that the smaller elastic modulus bonding system is the first choice, such as Superbond C&B.

  4. Microscale anechoic architecture: acoustic diffusers for ultra low power microparticle separation via traveling surface acoustic waves.

    PubMed

    Behrens, Jan; Langelier, Sean; Rezk, Amgad R; Lindner, Gerhard; Yeo, Leslie Y; Friend, James R

    2015-01-07

    We present a versatile and very low-power traveling SAW microfluidic sorting device able to displace and separate particles of different diameter in aqueous suspension; the travelling wave propagates through the fluid bulk and diffuses via a Schröder diffuser, adapted from its typical use in concert hall acoustics to be the smallest such diffuser to be suitable for microfluidics. The effective operating power range is two to three orders of magnitude less than current SAW devices, uniquely eliminating the need for amplifiers, and by using traveling waves to impart forces directly upon suspended microparticles, they can be separated by size.

  5. Gustatory receptor neuron responds to DEET and other insect repellents in the yellow-fever mosquito, Aedes aegypti

    NASA Astrophysics Data System (ADS)

    Sanford, Jillian L.; Shields, Vonnie D. C.; Dickens, Joseph C.

    2013-03-01

    Three gustatory receptor neurons were characterized for contact chemoreceptive sensilla on the labella of female yellow-fever mosquitoes, Aedes aegypti. The neuron with the smallest amplitude spike responded to the feeding deterrent, quinine, as well as N, N-diethyl-3-methylbenzamide and other insect repellents. Two other neurons with differing spikes responded to salt (NaCl) and sucrose. This is the first report of a gustatory receptor neuron specific for insect repellents in mosquitoes and may provide a tool for screening chemicals to discover novel or improved feeding deterrents and repellents for use in the management of arthropod disease vectors.

  6. Experimental investigation on the effects of swirling flow on augmentor performance

    NASA Astrophysics Data System (ADS)

    Tan, Haoyuan; Huang, Xianjian

    1991-06-01

    This paper describes an investigation on the effect of centrifugal force distributions on swirl augmentor performance. The experiments were conducted on the flow drag, temperature-distribution efficiency in the swirl augmentor model with different tangential velocity profiles. Four tangential velocity distributions considered are the Rankine vortex, forced vortex, free vortex, and the constant-angle vortex. The results show that the flow drag of the Rankine vortex swirler is the smallest one, and, in a swirl augmentor where flame is stabilized by using centrifugal force, the combustion efficiency can reach 90 percent or over, though the swirl number is low (S = 0.25).

  7. National Rugby League athletes and tendon tap reflex assessment: a matched cohort clinical study.

    PubMed

    Maurini, James; Ohmsen, Paul; Condon, Greg; Pope, Rodney; Hing, Wayne

    2016-11-04

    Limited research suggests elite athletes may differ from non-athletes in clinical tendon tap reflex responses. In this matched cohort study, 25 elite rugby league athletes were compared with 29 non-athletes to examine differences in tendon reflex responses. Relationships between reflex responses and lengths of players' careers were also examined. Biceps, triceps, patellar and Achilles tendon reflexes were clinically assessed. Right and left reflexes were well correlated for each tendon (r S  = 0.7-0.9). The elite rugby league athletes exhibited significantly weaker reflex responses than non-athletes in all four tendons (p < 0.005). Biceps reflexes demonstrated the largest difference and Achilles reflexes the smallest difference. Moderate negative correlations (r S  = -0.3-0.6) were observed between reflex responses and lengths of players' careers. Future research is required to further elucidate mechanisms resulting in the observed differences in tendon reflexes and to ensure clinical tendon tap examinations and findings can be interpreted appropriately in this athletic population.

  8. L(2,1)-Labeling of the Strong Product of Paths and Cycles

    PubMed Central

    2014-01-01

    An L(2,1)-labeling of a graph G = (V, E) is a function f from the vertex set V(G) to the set of nonnegative integers such that the labels on adjacent vertices differ by at least two and the labels on vertices at distance two differ by at least one. The span of f is the difference between the largest and the smallest numbers in f(V). The λ-number of G, denoted by λ(G), is the minimum span over all L(2,1)-labelings of G. We consider the λ-number of P n⊠C m and for n ≤ 11 the λ-number of C n⊠C m. We determine λ-numbers of graphs of interest with the exception of a finite number of graphs and we improve the bounds on the λ-number of C n⊠C m, m ≥ 24 and n ≥ 26. PMID:24711734

  9. Complete denture base assessments using holograms: dimensional alterations after different activation methods

    NASA Astrophysics Data System (ADS)

    Dughir, Ciprian; Popovschi, Ana Maria; Cojocariu, Andreea Codruta; Topala, Florin Ionel; Negrutiu, Meda Lavinia; Sinescu, Cosmin; de Sabata, Aldo; Duma, Virgil-Florin

    2016-03-01

    Holography is a well-developed method with a large range of applications, including dentistry. This study uses holographic methods for the study of total dental prosthesis. The issue is that the transformation of wax denture base in polymethylacrylate causes dimensional alterations and retractions in the final dental constructs. These could cause the failure of the stability of the complete denture in the oral cavity. Thus, the aim of this study is to determine and to compare using holography, total prosthesis obtained using three different manufacturing methods: pressing, injection, and polymerization. Each of the three types of dentures thus produced were recorded over the previously wax complete base holographic plates. The dimensional alterations that appear after using the different activation methods were thus determined. The most significant modification was remarked in the custom press technology, while the smallest variations were detected in the injection alternative.

  10. Effects of Discrete Charge Clustering in Simulations of Charged Interfaces.

    PubMed

    Grime, John M A; Khan, Malek O

    2010-10-12

    A system of counterions between charged surfaces is investigated, with the surfaces represented by uniform charged planes and three different arrangements of discrete surface charges - an equispaced grid and two different clustered arrangements. The behaviors of a series of systems with identical net surface charge density are examined, with particular emphasis placed on the long ranged corrections via the method of "charged slabs" and the effects of the simulation cell size. Marked differences are observed in counterion distributions and the osmotic pressure dependent on the particular representation of the charged surfaces; the uniformly charged surfaces and equispaced grids of discrete charge behave in a broadly similar manner, but the clustered systems display a pronounced decrease in osmotic pressure as the simulation size is increased. The influence of the long ranged correction is shown to be minimal for all but the very smallest of system sizes.

  11. A multi-scale tensor voting approach for small retinal vessel segmentation in high resolution fundus images.

    PubMed

    Christodoulidis, Argyrios; Hurtut, Thomas; Tahar, Houssem Ben; Cheriet, Farida

    2016-09-01

    Segmenting the retinal vessels from fundus images is a prerequisite for many CAD systems for the automatic detection of diabetic retinopathy lesions. So far, research efforts have concentrated mainly on the accurate localization of the large to medium diameter vessels. However, failure to detect the smallest vessels at the segmentation step can lead to false positive lesion detection counts in a subsequent lesion analysis stage. In this study, a new hybrid method for the segmentation of the smallest vessels is proposed. Line detection and perceptual organization techniques are combined in a multi-scale scheme. Small vessels are reconstructed from the perceptual-based approach via tracking and pixel painting. The segmentation was validated in a high resolution fundus image database including healthy and diabetic subjects using pixel-based as well as perceptual-based measures. The proposed method achieves 85.06% sensitivity rate, while the original multi-scale line detection method achieves 81.06% sensitivity rate for the corresponding images (p<0.05). The improvement in the sensitivity rate for the database is 6.47% when only the smallest vessels are considered (p<0.05). For the perceptual-based measure, the proposed method improves the detection of the vasculature by 7.8% against the original multi-scale line detection method (p<0.05). Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. 40 CFR 240.101 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... pollutants released to the atmosphere. (g) Facility means all thermal processing equipment, buildings, and... hazards by spreading the solid wastes in thin layers, compacting the solid wastes to the smallest...

  13. 40 CFR 240.101 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... pollutants released to the atmosphere. (g) Facility means all thermal processing equipment, buildings, and... hazards by spreading the solid wastes in thin layers, compacting the solid wastes to the smallest...

  14. 40 CFR 240.101 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... pollutants released to the atmosphere. (g) Facility means all thermal processing equipment, buildings, and... hazards by spreading the solid wastes in thin layers, compacting the solid wastes to the smallest...

  15. Evaluation of Contemporary Holmium Laser Fibers for Performance Characteristics.

    PubMed

    Lusch, Achim; Heidari, Emon; Okhunov, Zhamshid; Osann, Kathryn; Landman, Jaime

    2016-05-01

    Several holmium:YAG laser fibers for urologic applications are currently commercially available. We compared contemporary holmium laser fibers with different core sizes for performance characteristics, including energy transmission, fiber failure, fiber flexibility, and core diameter. Single-use fibers from Cook, Boston Scientific, and Storz were tested in small (200 and 272/273 μm), medium (365 μm), and large (550 and 940/1000 μm) core sizes. Fibers were tested in straight and deflected configurations. All fibers were evaluated for flexibility, true fiber diameter, energy transmission, and fiber failure. For energy transmission, fibers were tested at a pulse energy of 1 J and a frequency of 10 Hz for 30 seconds. All tests were performed on a 30 W holmium laser. For the small core fibers, Storz, Cook OptiLite, and Smart Sync had the smallest core diameter (p < 0.005). In the large core group, Cook OptiLite and Boston Scientific AccuMax showed the smallest diameter. Among the small core fibers, Storz and Cook Smart Sync showed a significant higher deflection, whereas in the 550 μm group, Boston Scientific AccuMax and Cook Smart Sync were the most flexible fibers. In the large and medium core groups, Boston Scientific AccuMax showed superior energy transmission (p = 0.007 and p = 0.001, respectively), whereas in the small core group, there was no significant difference between the fibers, except for 272/3 μm (Storz was inferior compared with the competitors [p < 0.0005]). For fiber failure, Storz, Cook OptiLite, and BS AccuTrac completed all testing without failing (200 μm, bending radius <0.5 cm). In the 365 μm group, Cook OptiLite showed superior results, whereas in the large core group, Boston Scientific AccuMax was superior. Performance characteristics differ significantly between different laser fiber diameters and manufacturers, and fiber choice should depend on specific surgical requirements. There is a trend for less fiber fracture at long pulse, high energy, and low frequency, but this finding will require further investigation.

  16. Contrast-detail phantom scoring methodology.

    PubMed

    Thomas, Jerry A; Chakrabarti, Kish; Kaczmarek, Richard; Romanyukha, Alexander

    2005-03-01

    Published results of medical imaging studies which make use of contrast detail mammography (CDMAM) phantom images for analysis are difficult to compare since data are often not analyzed in the same way. In order to address this situation, the concept of ideal contrast detail curves is suggested. The ideal contrast detail curves are constructed based on the requirement of having the same product of the diameter and contrast (disk thickness) of the minimal correctly determined object for every row of the CDMAM phantom image. A correlation and comparison of five different quality parameters of the CDMAM phantom image determined for obtained ideal contrast detail curves is performed. The image quality parameters compared include: (1) contrast detail curve--a graph correlation between "minimal correct reading" diameter and disk thickness; (2) correct observation ratio--the ratio of the number of correctly identified objects to the actual total number of objects multiplied by 100; (3) image quality figure--the sum of the product of the diameter of the smallest scored object and its relative contrast; (4) figure-of-merit--the zero disk diameter value obtained from extrapolation of the contrast detail curve to the origin (e.g., zero disk diameter); and (5) k-factor--the product of the thickness and the diameter of the smallest correctly identified disks. The analysis carried out showed the existence of a nonlinear relationship between the above parameters, which means that use of different parameters of CDMAM image quality potentially can cause different conclusions about changes in image quality. Construction of the ideal contrast detail curves for CDMAM phantom is an attempt to determine the quantitative limits of the CDMAM phantom as employed for image quality evaluation. These limits are determined by the relationship between certain parameters of a digital mammography system and the set of the gold disks sizes in the CDMAM phantom. Recommendations are made on selections of CDMAM phantom regions which should be used for scoring at different image quality and which scoring methodology may be most appropriate. Special attention is also paid to the use of the CDMAM phantom for image quality assessment of digital mammography systems particularly in the vicinity of the Nyquist frequency.

  17. Evaluation of force-sensing resistors for gait event detection to trigger electrical stimulation to improve walking in the child with cerebral palsy.

    PubMed

    Smith, Brian T; Coiro, Daniel J; Finson, Richard; Betz, Randal R; McCarthy, James

    2002-03-01

    Force-sensing resistors (FSRs) were used to detect the transitions between five main phases of gait for the control of electrical stimulation (ES) while walking with seven children with spastic diplegia, cerebral palsy. The FSR positions within each child's insoles were customized based on plantar pressure profiles determined using a pressure-sensitive membrane array (Tekscan Inc., Boston, MA). The FSRs were placed in the insoles so that pressure transitions coincided with an ipsilateral or contralateral gait event. The transitions between the following gait phases were determined: loading response, mid- and terminal stance, and pre- and initial swing. Following several months of walking on a regular basis with FSR-triggered intramuscular ES to the hip and knee extensors, hip abductors, and ankle dorsi and plantar flexors, the accuracy and reliability of the FSRs to detect gait phase transitions were evaluated. Accuracy was evaluated with four of the subjects by synchronizing the output of the FSR detection scheme with a VICON (Oxford Metrics, U.K.) motion analysis system, which was used as the gait event reference. While mean differences between each FSR-detected gait event and that of the standard (VICON) ranged from +35 ms (indicating that the FSR detection scheme recognized the event before it actually happened) to -55 ms (indicating that the FSR scheme recognized the event after it occurred), the difference data was widely distributed, which appeared to be due in part to both intrasubject (step-to-step) and intersubject variability. Terminal stance exhibited the largest mean difference and standard deviation, while initial swing exhibited the smallest deviation and preswing the smallest mean difference. To determine step-to-step reliability, all seven children walked on a level walkway for at least 50 steps. Of 642 steps, there were no detection errors in 94.5% of the steps. Of the steps that contained a detection error, 80% were due to the failure of the FSR signal to reach the programmed threshold level during the transition to loading response. Recovery from an error always occurred one to three steps later.

  18. Sizing Up Exoplanets

    NASA Image and Video Library

    2012-01-11

    Astronomers using data from NASA Kepler mission and ground-based telescopes recently discovered the three smallest exoplanets known to circle another star, called KOI-961.01, KOI-961.02 and KOI-961.03.

  19. Retinal detachment

    MedlinePlus

    ... eye, including the retina ( ophthalmoscopy ) Checking eyeglass prescription ( refraction test ) Checking color vision Checking the smallest letters ... of the first symptoms of new flashes of light and floaters. Prevention Use protective eye wear to ...

  20. Soft Polymers for Building up Small and Smallest Blood Supplying Systems by Stereolithography

    PubMed Central

    Meyer, Wolfdietrich; Engelhardt, Sascha; Novosel, Esther; Elling, Burkhard; Wegener, Michael; Krüger, Hartmut

    2012-01-01

    Synthesis of a homologous series of photo-polymerizable α,ω-polytetrahydrofuranether-diacrylate (PTHF-DA) resins is described with characterization by NMR, GPC, DSC, soaking and rheometrical measurements. The curing speeds of the resins are determined under UV light exposure. Young’s modulus and tensile strength of fully cured resins show flexible to soft material attributes dependent on the molar mass of the used linear PTHF-diacrylates. Structuring the materials by stereo lithography (SL) and multiphoton polymerization (MPP) leads to tubes and bifurcated tube systems with a diameter smaller than 2 mm aimed at small to smallest supplying systems with capillary dimensions. WST-1 biocompatibility tests ofm polymer extracts show nontoxic characteristics of the adapted polymers after a washing process. Some polymers show shape memory effect (SME). PMID:24955530

  1. Water exchange through the Kerama Gap estimated with a 25-year Pacific HYbrid Coordinate Ocean Model

    NASA Astrophysics Data System (ADS)

    Zhou, Wenzheng; Yu, Fei; Nan, Feng

    2017-11-01

    Variations in water exchange through the Kerama Gap (between Okinawa Island and Miyakojima Island) from 1979 to 2003 were estimated with the 0.08° Pacific HYbrid Coordinate Ocean Model (HYCOM). The model results show that the mean transport through the Kerama Gap (KGT) from the Pacific Ocean to the East China Sea (ECS) was 2.1 Sv, which agrees well with the observed mean KGT (2.0 Sv) for 2009-2010. Over the time period examined, the monthly KGT varied from -10.9 Sv to 15.8 Sv and had a standard deviation of ± 5.0 Sv. The water mainly enters the ECS via the subsurface layer (300-500 m) along the northeastern slope of the Kerama Gap and mainly flows out of the ECS into the southwest of the Kerama Gap. The seasonal and interannual variations of the KGT and the Kuroshio upstream transport were negatively correlated. The Kuroshio upstream transport was largest in summer and smallest in autumn while the KGT was smallest in summer (1.02 Sv) and largest in spring (2.94 Sv) and autumn (2.44 Sv). The seasonal and interannual variations in the Kuroshio downstream (across the PN-line) transport differed significantly from the Kuroshio upstream transport but corresponded well with the KGT and the sum of the transport through the Kerama Gap and the Kuroshio upstream, which indicates that information about variation in the KGT is important for determining variation in the Kuroshio transport along the PN-line.

  2. Liquid Jet Cavitation via Molecular Dynamics

    NASA Astrophysics Data System (ADS)

    Ashurst, W. T.

    1997-11-01

    A two-dimensional molecular dynamics simulation of a liquid jet is used to investigate cavitation in a diesel-like fuel injector. A channel with a length four times its width has been examined at various system sizes (widths of 20 to 160 σ, where σ is the zero energy location in the Lennard-Jones potential). The wall boundary condition is Maxwell's diffuse reflection, similar to the work by Sun & Ebner (Phys. Rev A 46, 4813, 1992). Currently, the jet exhausts into a vacuum, but a second, low density gas will be incorporated to represent the compressed air in a diesel chamber. Four different flow rates are examined. With ρ U equal to √mɛ/σ^2 (the largest flow rate) the static pressure decreases by a factor of twenty between the channel entrance and exit. The largest flow rate has a parabolic velocity profile with almost constant density across the channel. The smallest flow rate has the same velocity profile but the density exhibits a large variation, with the minimum value in the channel center. Thus, the product ρ U is nearly constant across the channel at this flow rate. The discharge coefficient CD has a small variation with flow rate, but the velocity coefficient CV varies with the amount of two-phase fluid within the channel. The ratio of CV to CD varies from 1.3 (largest flow rate) to 2.0 (the smallest flow rate, which is one-eighth of the largest).

  3. The Estimation of Gestational Age at Birth in Database Studies.

    PubMed

    Eberg, Maria; Platt, Robert W; Filion, Kristian B

    2017-11-01

    Studies on the safety of prenatal medication use require valid estimation of the pregnancy duration. However, gestational age is often incompletely recorded in administrative and clinical databases. Our objective was to compare different approaches to estimating the pregnancy duration. Using data from the Clinical Practice Research Datalink and Hospital Episode Statistics, we examined the following four approaches to estimating missing gestational age: (1) generalized estimating equations for longitudinal data; (2) multiple imputation; (3) estimation based on fetal birth weight and sex; and (4) conventional approaches that assigned a fixed value (39 weeks for all or 39 weeks for full term and 35 weeks for preterm). The gestational age recorded in Hospital Episode Statistics was considered the gold standard. We conducted a simulation study comparing the described approaches in terms of estimated bias and mean square error. A total of 25,929 infants from 22,774 mothers were included in our "gold standard" cohort. The smallest average absolute bias was observed for the generalized estimating equation that included birth weight, while the largest absolute bias occurred when assigning 39-week gestation to all those with missing values. The smallest mean square errors were detected with generalized estimating equations while multiple imputation had the highest mean square errors. The use of generalized estimating equations resulted in the most accurate estimation of missing gestational age when birth weight information was available. In the absence of birth weight, assignment of fixed gestational age based on term/preterm status may be the optimal approach.

  4. Predator size and the suitability of a common prey.

    PubMed

    Erickson, Kristin S; Morse, D H

    1997-02-01

     Although a predator's mass should influence the suitability of its prey, this subject has received little direct attention. We studied the capture and processing of an abundant syrphid fly Toxomerus marginatus (c. 4 mg) by 0.6- to 40-mg juvenile crab spiders Misumena vatia (Thomisidae) to determine how profitability, relative profitability (profitability/predator mass), overall gain in mass, and relative gain in mass differed with predator mass, and whether foraging changed concurrently. In multi-prey experiments, the smallest successful spiders (0.6-3.0 mg) extracted less mass from flies, and did so more slowly, than large spiders. This gain was proportionately similar to that of 10- to 40-mg spiders with access to many Toxomerus. However, many small spiders failed to capture flies. When we gave spiders only a single Toxomerus, the smallest ones again extracted mass more slowly than the large ones and increased in mass less than the large ones, but increased in mass proportionately more than large ones. Relative gain in mass from a single prey decreased with increasing spider mass. Spiders larger than 10 mg all extracted similar amounts of mass from a single Toxomerus at similar rates, but varied in time spent between captures. Thus, Toxomerus changes with spider mass from a large, hard-to-capture bonanza to a small, easy-to-capture item of low per capita value. However, Toxomerus is common enough that large spiders can capture it en masse, thereby compensating for its decline in per capita value.

  5. Synthesis, antihyperglycemic activity and computational studies of antioxidant chalcones and flavanones derived from 2,5 dihydroxyacetophenone

    NASA Astrophysics Data System (ADS)

    Tajammal, Affifa; Batool, Majda; Ramzan, Ayesha; Samra, Malka M.; Mahnoor, Idrees; Verpoort, Francis; Irfan, Ahmad; Al-Sehemi, Abdullah G.; Munawar, Munawar Ali; Basra, Muhammad Asim R.

    2017-11-01

    Chronic exposure of supraphysiologic glucose concentration to cells and tissues resulted in glucose toxicity which causes oxidative stress. Antioxidants have promising effect in suppressing the oxidative stress in the pathogenesis of diabetes mellitus (DM). Condensation of 2,5-dihydroxyacetophenone with different nitrobenzaldehydes was used to synthesize antioxidant nitro substituted chalcones along with nitro substituted flavanones in one step protocol. The compounds were characterized by IR, 1H NMR and 13C NMR and then screened for their in vitro antioxidant and in vivo antihyperglycemic activities. Postulated structures of the synthesized compounds were in agreement with their spectral data. The results indicated that the novel compound (2E)-1-(2,5-Dihydroxyphenyl)-3-(2-nitrophenyl) prop-2-en-1-one (2a) was potent antioxidant because of its lower IC50 value compared with trolox and ascorbic acid. Compound 2a also exhibited excellent antihyperglycemic activity in diabetic rats while the compound (E)-1-(2,5-Dihydroxyphenyl)-3-(4-nitrophenyl)prop-2-one (2c) suppressed the hyperglycemia more effectively in normal rats. The radical scavenging activity behavior was elucidated on the basis of hydrogen atom transfer and one-electron transfer mechanisms by density functional theory (DFT). The compound 2a showed the smallest ionization potential and bond dissociation enthalpy. Experimental and computational investigations concluded that compound 2a might be an effective antihyperglycemic agent because of its antioxidative nature and smallest ionization potential.

  6. Synthesis and characterization of nanometric magnetite coated by oleic acid and the surfactant CTAB. Surfactant coated nanometric magnetite/maghemite

    NASA Astrophysics Data System (ADS)

    Celis, J. Almazán; Olea Mejía, O. F.; Cabral-Prieto, A.; García-Sosa, I.; Derat-Escudero, R.; Baggio Saitovitch, E. M.; Alzamora Camarena, M.

    2017-11-01

    Nanometric magnetite ( nm-Fe3O4) particles were prepared by the reverse co-precipitation synthesis method, obtaining particle sizes that ranged from 4 to 8.5 nm. In their synthesis, the concentration of iron salts of ferric nitrate, Fe(NO3)3ṡ9H2O, and ferrous sulfate, FeSO4ṡ7H2O, were varied relative to the chemical reaction volume and by using different surfactants such as oleic acid (OA) and hexadecyltrimethylammonium bromide (CTAB). The nm-Fe3O4 particles were characterized by transmission electron microscopy (TEM), Mössbauer spectroscopy (MS), magnetic and X-ray diffraction (XRD) measurements. Typical asymmetrical and/or broad lines shapes appeared in all Mössbauer spectra of the as prepared samples suggesting strong magnetic inter-particle interactions, reducing these interactions to some extent by gentle mechanical grinding. For the smallest particles, maghemite instead of magnetite was the main preparation product as low temperature Mössbauer and magnetic measurements indicated. For the intermediate and largest particles a mixture of magnetite and maghemite phases were produced as the saturation magnetization values of MS ˜ 60 emu/g indicated; these values were measured for most samples, independently of the coating surfactant concentration, and according to the ZFC-FC curves the blocking temperatures were 225K and 275K for the smallest and largest magnetite nanoparticles, respectively. The synthesis method was highly reproducible.

  7. Quantification of pulmonary vessel diameter in low-dose CT images

    NASA Astrophysics Data System (ADS)

    Rudyanto, Rina D.; Ortiz de Solórzano, Carlos; Muñoz-Barrutia, Arrate

    2015-03-01

    Accurate quantification of vessel diameter in low-dose Computer Tomography (CT) images is important to study pulmonary diseases, in particular for the diagnosis of vascular diseases and the characterization of morphological vascular remodeling in Chronic Obstructive Pulmonary Disease (COPD). In this study, we objectively compare several vessel diameter estimation methods using a physical phantom. Five solid tubes of differing diameters (from 0.898 to 3.980 mm) were embedded in foam, simulating vessels in the lungs. To measure the diameters, we first extracted the vessels using either of two approaches: vessel enhancement using multi-scale Hessian matrix computation, or explicitly segmenting them using intensity threshold. We implemented six methods to quantify the diameter: three estimating diameter as a function of scale used to calculate the Hessian matrix; two calculating equivalent diameter from the crosssection area obtained by thresholding the intensity and vesselness response, respectively; and finally, estimating the diameter of the object using the Full Width Half Maximum (FWHM). We find that the accuracy of frequently used methods estimating vessel diameter from the multi-scale vesselness filter depends on the range and the number of scales used. Moreover, these methods still yield a significant error margin on the challenging estimation of the smallest diameter (on the order or below the size of the CT point spread function). Obviously, the performance of the thresholding-based methods depends on the value of the threshold. Finally, we observe that a simple adaptive thresholding approach can achieve a robust and accurate estimation of the smallest vessels diameter.

  8. Age, growth, and reproductive biology of three catostomids from the Apalachicola River, Florida

    USGS Publications Warehouse

    Grabowski, Timothy B.; Young, S.P.; Isely, J.J.; Ely, Patrick C.

    2012-01-01

    Riverine catostomids can show a wide range of interspecific variation in life-history characteristics. Understanding these differences is an important consideration in evaluating the sensitivity of these fishes to disturbance and in formulating effective conservation strategies, particularly when dealing with an assemblage consisting of multiple species within a watershed. We collected Apalachicola redhorse Moxostoma n. sp. cf. poecilurum (n = 125), spotted sucker Minytrema melanops (n = 94), and quillback Carpiodes cyprinus (n = 94) to determine age, growth, and reproductive biology of spawning catostomids in the Apalachicola River, Florida, during 2007. Quillback was the smallest in total length at age; longest-lived; most fecund; and produced the smallest eggs. Apalachicola redhorse was the largest in body size; had an intermediate life span; and produced the fewest yet largest eggs. Spotted sucker was more similar to Apalachicola redhorse in most characteristics. Growth during ages 1-3 in all three species seemed to be negatively related to the proportion of observations of extreme flow, both high (Q90) and low (Q10), per year and a positive response in growth rate to high flows (>Q75 but < Q90). However, Apalachicola redhorse and spotted sucker growth was more sensitive to flow conditions than that of quillback. Our results suggest the life histories and ecological response of Apalachicola River catostomids to flow regulation are important components for developing strategies that incorporate the needs of these fishery resources into an ecosystem-based management approach.

  9. Encephalomyocarditis Virus Ribonucleic Acid Polymerase Associated with 150S Cytoplasmic Particles

    PubMed Central

    Bases, Robert; Tarikas, Helgi

    1969-01-01

    Cytoplasmic particles which sedimented at 150S were the smallest structures containing detectable viral ribonucleic acid polymerase in mouse cells infected with encephalomyocarditis virus. PMID:4307906

  10. Setting occupational health standards: toxicokinetic differences among and between men and women.

    PubMed

    Silvaggio, T; Mattison, D R

    1994-08-01

    Differences between and among men, nonpregnant women, and pregnant women can influence exposure and response to workplace toxicants. These differences should be delineated, compared, and used when setting regulatory standards to protect workers from potentially hazardous workplace environments. Anatomical and physiological parameters include: body composition; surface area; blood, organ, and tissue volume; metabolism; and cardiovascular, pulmonary, gastrointestinal, and renal structure and function. Although men differ among themselves, on average, they also differ from women by weighing more, being taller, and having a larger surface area. Total body water is 40% greater in men than nonpregnant women; however, during pregnancy, body water increases from 29 to 33 liters. Extracellular and intracellular water volumes are smallest in nonpregnant women, increase with pregnancy, but remain smaller than those in men. Pulmonary function differs; pregnant women have the largest minute volume and greatest volume of air exchanged in an 8-hour period. This article compares anatomical, physiological, and toxicokinetic characteristics of men and nonpregnant and pregnant women to explore how differences in these factors contribute to variations in exposures, target tissue doses, and responses to workplace or environmental chemicals.

  11. Investigation of the adsorption of polymer chains on amine-functionalized double-walled carbon nanotubes.

    PubMed

    Ansari, R; Ajori, S; Rouhi, S

    2015-12-01

    Molecular dynamics (MD) simulations were used to study the adsorption of different polymer chains on functionalized double-walled carbon nanotubes (DWCNTs). The nanotubes were functionalized with two different amines: NH2 (a small amine) and CH2-NH2 (a large amine). Considering three different polymer chains, all with the same number of atoms, the effect of polymer type on the polymer-nanotube interaction was studied. In general, it was found that covalent functionalization considerably improved the polymer-DWCNT interaction. By comparing the results obtained with different polymer chains, it was observed that, unlike polyethylene and polyketone, poly(styrene sulfonate) only weakly interacts with the functionalized DWCNTs. Accordingly, the smallest radius of gyration was obtained with adsorbed poly(styrene sulfonate). It was also observed that the DWCNTs functionalized with the large amine presented more stable interactions with polyketone and poly(styrene sulfonate) than with polyethylene, whereas the DWCNTs functionalized with the small amine showed better interfacial noncovalent bonding with polyethylene.

  12. The evolution of sensory divergence in the context of limited gene flow in the bumblebee bat

    PubMed Central

    Puechmaille, Sébastien J.; Gouilh, Meriadeg Ar; Piyapan, Piyathip; Yokubol, Medhi; Mie, Khin Mie; Bates, Paul J.; Satasook, Chutamas; Nwe, Tin; Bu, Si Si Hla; Mackie, Iain J.; Petit, Eric J.; Teeling, Emma C.

    2011-01-01

    The sensory drive theory of speciation predicts that populations of the same species inhabiting different environments can differ in sensory traits, and that this sensory difference can ultimately drive speciation. However, even in the best-known examples of sensory ecology driven speciation, it is uncertain whether the variation in sensory traits is the cause or the consequence of a reduction in levels of gene flow. Here we show strong genetic differentiation, no gene flow and large echolocation differences between the allopatric Myanmar and Thai populations of the world's smallest mammal, Craseonycteris thonglongyai, and suggest that geographic isolation most likely preceded sensory divergence. Within the geographically continuous Thai population, we show that geographic distance has a primary role in limiting gene flow rather than echolocation divergence. In line with sensory-driven speciation models, we suggest that in C. thonglongyai, limited gene flow creates the suitable conditions that favour the evolution of sensory divergence via local adaptation. PMID:22146392

  13. Dependency Distance Differences across Interpreting Types: Implications for Cognitive Demand

    PubMed Central

    Liang, Junying; Fang, Yuanyuan; Lv, Qianxi; Liu, Haitao

    2017-01-01

    Interpreting is generally recognized as a particularly demanding language processing task for the cognitive system. Dependency distance, the linear distance between two syntactically related words in a sentence, is an index of sentence complexity and is also able to reflect the cognitive constraints during various tasks. In the current research, we examine the difference in dependency distance among three interpreting types, namely, simultaneous interpreting, consecutive interpreting and read-out translated speech based on a treebank comprising these types of interpreting output texts with dependency annotation. Results show that different interpreting renditions yield different dependency distances, and consecutive interpreting texts entail the smallest dependency distance other than those of simultaneous interpreting and read-out translated speech, suggesting that consecutive interpreting bears heavier cognitive demands than simultaneous interpreting. The current research suggests for the first time that interpreting is an extremely demanding cognitive task that can further mediate the dependency distance of output sentences. Such findings may be due to the minimization of dependency distance under cognitive constraints. PMID:29312027

  14. Spline-based procedures for dose-finding studies with active control

    PubMed Central

    Helms, Hans-Joachim; Benda, Norbert; Zinserling, Jörg; Kneib, Thomas; Friede, Tim

    2015-01-01

    In a dose-finding study with an active control, several doses of a new drug are compared with an established drug (the so-called active control). One goal of such studies is to characterize the dose–response relationship and to find the smallest target dose concentration d*, which leads to the same efficacy as the active control. For this purpose, the intersection point of the mean dose–response function with the expected efficacy of the active control has to be estimated. The focus of this paper is a cubic spline-based method for deriving an estimator of the target dose without assuming a specific dose–response function. Furthermore, the construction of a spline-based bootstrap CI is described. Estimator and CI are compared with other flexible and parametric methods such as linear spline interpolation as well as maximum likelihood regression in simulation studies motivated by a real clinical trial. Also, design considerations for the cubic spline approach with focus on bias minimization are presented. Although the spline-based point estimator can be biased, designs can be chosen to minimize and reasonably limit the maximum absolute bias. Furthermore, the coverage probability of the cubic spline approach is satisfactory, especially for bias minimal designs. © 2014 The Authors. Statistics in Medicine Published by John Wiley & Sons Ltd. PMID:25319931

  15. Main predators of insect pests: screening and evaluation through comprehensive indices.

    PubMed

    Yang, Tingbang; Liu, Jie; Yuan, Longyu; Zhang, Yang; Peng, Yu; Li, Daiqin; Chen, Jian

    2017-11-01

    Predatory natural enemies play key functional roles in integrated pest management. However, the screening and evaluation of the main predators of insect pests has seldom been reported in the field. Here, we employed comprehensive indices for evaluating the predation of a common pest (Ectropis obliqua) by nine common spider species in Chinese tea plantations. We established the relative dominance of the spider species and their phenological overlap with the pest species, and analyzed DNA from the nine spider species using targeted real-time quantitative polymerase chain reaction to identify the residual DNA of E. obliqua. The predation rates and predation numbers per predator were estimated by the positive rates of target fragments and the residual minimum number of E. obliqua in predators' guts, respectively. The results showed that only four spider species preyed on E. obliqua, and the order of potential of the spiders to control E. obliqua from greatest to smallest was Neoscona mellotteei, Xysticus ephippiatus, Evarcha albaria and Coleosoma octomaculatum by the Z-score method. The orb-weaving spider N. mellotteei has the maximum potential as a biological control agent of E. obliqua in an integrated pest management strategy. An approach of screening and evaluating main predators of insect pests through comprehensive indices was preliminarily established. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  16. Comparison of prediction methods for oxygen-18 isotope composition in shallow groundwater.

    PubMed

    Cerar, Sonja; Mezga, Kim; Žibret, Gorazd; Urbanc, Janko; Komac, Marko

    2018-08-01

    Groundwater is the most important source of drinking water in the world. Therefore, information on the quality and quantity is important, as is new information related to the characteristics of the aquifer and the recharge area. In the present study we focused on the isotope composition of oxygen (δ 18 O) in groundwater, which is a natural tracer and provides a better understanding of the water cycle, in terms of origin, dynamics and interaction. The groundwater δ 18 O at 83 locations over the entire Slovenian territory was studied. Each location was sampled twice during the period 2009-2011. Geostatistical tools (such us ordinary kriging, simple and multiple linear regressions, and artificial neural networks were used and compared to select the best tool. Measured values of δ 18 O in the groundwater were used as the dependent variable, while the spatial characteristics of the territory (elevation, distance from the sea and average annual precipitation) were used as independent variables. Based on validation data sets, the artificial neural network model proved to be the most suitable method for predicting δ 18 O in the groundwater, since it produced the smallest deviations from the real/measured values in groundwater. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Ginzburg-Landau theory for the solid-liquid interface of bcc elements

    NASA Technical Reports Server (NTRS)

    Shih, W. H.; Wang, Z. Q.; Zeng, X. C.; Stroud, D.

    1987-01-01

    Consideration is given to a simple order-parameter theory for the interfacial tension of body-centered-cubic solids in which the principal order parameter is the amplitude of the density wave at the smallest nonzero reciprocal-lattice vector of the solid. The parameters included in the theory are fitted to the measured heat of fusion, melting temperature, and solid-liquid density difference, and to the liquid structure factor and its temperature derivative at freezing. Good agreement is found with experiment for Na and Fe and the calculated anisotropy of the surface tension among different crystal faces is of the order of 2 percent. On the basis of various assumptions about the universal behavior of bcc crystals at melting, the formalism predicts that the surface tension is proportional to the heat of fusion per surface atom.

  18. Polyethylene Oxide (PEO) and Polyethylene Glycol (PEG) Polymer Sieving Matrix for RNA Capillary Electrophoresis

    PubMed Central

    Yamaguchi, Yoshinori; Li, Zhenqing; Zhu, Xifang; Liu, Chenchen; Zhang, Dawei; Dou, Xiaoming

    2015-01-01

    The selection of sieving polymer for RNA fragments separation by capillary electrophoresis is imperative. We investigated the separation of RNA fragments ranged from 100 to 10,000 nt in polyethylene glycol (PEG) and polyethylene oxide (PEO) solutions with different molecular weight and different concentration. We found that the separation performance of the small RNA fragments (<1000 nt) was improved with the increase of polymer concentration, whereas the separation performance for the large ones (>4000 nt) deteriorated in PEG/PEO solutions when the concentration was above 1.0%/0.6%, respectively. By double logarithmic plot of mobility and RNA fragment size, we revealed three migration regimes for RNA in PEG (300-500k) and PEO (4,000k). Moreover, we calculated the smallest resolvable nucleotide length (N min) from the resolution length analysis. PMID:25933347

  19. Selecting band combinations with thematic mapper data

    NASA Technical Reports Server (NTRS)

    Sheffield, C. A.

    1983-01-01

    A problem arises in making color composite images because there are 210 different possible color presentations of TM three-band images. A method is given for reducing that 210 to a single choice, decided by the statistics of a scene or subscene, and taking into full account any correlations that exist between different bands. Instead of using total variance as the measure for information content of the band triplets, the ellipsoid of maximum volume is selected which discourages selection of bands with high correlation. The band triplet is obtained by computing and ranking in order the determinants of each 3 x 3 principal submatrix of the original matrix M. After selection of the best triplet, the assignment of colors is made by using the actual variances (the diagonal elements of M): green (maximum variance), red (second largest variance), blue (smallest variance).

  20. Helium diffusion in carbonates

    NASA Astrophysics Data System (ADS)

    Amidon, W. H.; Cherniak, D. J.; Watson, E. B.; Hobbs, D.

    2013-12-01

    The abundance and large grain size of carbonate minerals make them a potentially attractive target for 4He thermochronology and 3He cosmogenic dating, although the diffusive properties of helium in carbonates remain poorly understood. This work characterizes helium diffusion in calcite and dolomite to better understand the crystal-chemical factors controlling He transport and retentivity. Slabs of cleaved natural calcite and dolomite, and polished sections of calcite cut parallel or normal to c, were implanted with 3He at 3 MeV with a dose of 5x1015/cm2. Implanted carbonates were heated in 1-atm furnaces, and 3He distributions following diffusion anneals were profiled with Nuclear Reaction Analysis using the reaction 3He(d,p)4He. For 3He transport normal to cleavage surfaces in calcite, we obtain the following Arrhenius relation over the temperature range 78-300°C: Dcalcite = 9.0x10-9exp(-55 × 6 kJ mol-1/RT) m2sec-1. Diffusion in calcite exhibits marked anisotropy, with diffusion parallel to c about two orders of magnitude slower than diffusion normal to cleavage faces. He diffusivities for transport normal to the c-axis are similar in value to those normal to cleavage surfaces. Our findings are broadly consistent with helium diffusivities from step-heating measurements of calcite by Copeland et al. (2007); these bulk degassing data may reflect varying effects of diffusional anisotropy. Helium diffusion normal to cleavage surfaces in dolomite is significantly slower than diffusion in calcite, and has a much higher activation energy for diffusion. For dolomite, we obtain the following Arrhenius relation for He diffusion over the temperature range 150-400°C: Ddolomite = 9.0x10-8exp(-92 × 9 kJ mol-1/RT) m2sec-1. The role of crystallographic structure in influencing these differences among diffusivities was evaluated using the maximum aperture approach of Cherniak and Watson (2011), in which crystallographic structures are sectioned along possible diffusion directions and the maximum interstitial apertures in each 'slice' in the structure are identified. Preliminary results show that observed differences in diffusivities are consistent with the size of the smallest maximum aperture along each diffusion direction. In calcite, the smallest maximum apertures are ~0.92 and ~0.66 angstroms for cleavage-normal and c-axis parallel directions respectively. In dolomite, the smallest maximum aperture is ~0.78 angstroms for the cleavage normal direction. Work is in progress on characterizing helium diffusion for other orientations in dolomite, and in other carbonates, including aragonite and magnesite, and in implementing these diffusion findings in the interpretation and modeling of bulk volume diffusion in heterogeneous calcite crystals common in many geologic applications. Copeland et al. (2007) GCA 71, 4488-4511 Cherniak and Watson, (2011) Chem. Geo. 288, 149-161

  1. Teaching communication skills in clinical settings: comparing two applications of a comprehensive program with standardized and real patients

    PubMed Central

    2014-01-01

    Background Communication is important for the quality of clinical practice, and programs have been implemented to improve healthcare providers’ communication skills. However, the consistency of programs teaching communication skills has received little attention, and debate exists about the application of acquired skills to real patients. This study inspects whether (1) results from a communication program are replicated with different samples, and (2) results with standardized patients apply to interviews with real patients. Methods A structured, nine-month communication program was applied in two consecutive years to two different samples of healthcare professionals (25 in the first year, 20 in the second year). Results were assessed at four different points in time, each year, regarding participants’ confidence levels (self-rated), basic communication skills in interviews with standardized patients, and basic communication skills in interviews with real patients. Data were analyzed using GLM Repeated-Measures procedures. Results Improvements were statistically significant in both years in all measures except in simulated patients’ assessment of the 2008 group. Differences between the two samples were non-significant. Differences between interviews with standardized and with real patients were also non-significant. Conclusions The program’s positive outcomes were replicated in different samples, and acquired skills were successfully applied to real-patient interviews. This reinforces this type of program structure as a valuable training tool, with results translating into real situations. It also adds to the reliability of the assessment instruments employed, though these may need adaptation in the case of real patients. PMID:24886341

  2. Fab Five

    NASA Image and Video Library

    2010-11-04

    This montage from NASA EPOXI mission shows the only five comets imaged up close with spacecraft. The comets vary in shape and size. Comet Hartley 2 is by far the smallest and the most active of small comets.

  3. 7 CFR 51.344 - Size.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., CERTIFICATION, AND STANDARDS) United States Standards for Grades of Apples for Processing Size § 51.344 Size. (a... buyer and seller. (c) Size is the dimension of the apples determined by the smallest opening through...

  4. 7 CFR 51.344 - Size.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ..., CERTIFICATION, AND STANDARDS) United States Standards for Grades of Apples for Processing Size § 51.344 Size. (a... buyer and seller. (c) Size is the dimension of the apples determined by the smallest opening through...

  5. 7 CFR 51.344 - Size.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Standards for Grades of Apples for Processing Size § 51.344 Size. (a) The minimum and maximum sizes or range... the apples determined by the smallest opening through which it will pass. Application of Standards ...

  6. 7 CFR 51.344 - Size.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Standards for Grades of Apples for Processing Size § 51.344 Size. (a) The minimum and maximum sizes or range... the apples determined by the smallest opening through which it will pass. Application of Standards ...

  7. 7 CFR 51.344 - Size.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Standards for Grades of Apples for Processing Size § 51.344 Size. (a) The minimum and maximum sizes or range... the apples determined by the smallest opening through which it will pass. Application of Standards ...

  8. Fast Food: Tips for Choosing Healthier Options

    MedlinePlus

    ... meal choices when going to a fast-food restaurant. By Mayo Clinic Staff Does following a weight- ... order. Consider these tips. If the fast-food restaurant offers several sandwich sizes, pick the smallest. Bypass ...

  9. Li2 B12 and Li3 B12 : Prediction of the Smallest Tubular and Cage-like Boron Structures.

    PubMed

    Dong, Xue; Jalife, Said; Vásquez-Espinal, Alejandro; Ravell, Estefanía; Pan, Sudip; Cabellos, José Luis; Liang, Wei-Yan; Cui, Zhong-Hua; Merino, Gabriel

    2018-04-16

    An intriguing structural transition from the quasi-planar form of B 12 cluster upon the interaction with lithium atoms is reported. High-level computations show that the lowest energy structures of LiB 12 , Li 2 B 12 , and Li 3 B 12 have quasi-planar (C s ), tubular (D 6d ), and cage-like (C s ) geometries, respectively. The energetic cost of distorting the B 12 quasi-planar fragment is overcompensated by an enhanced electrostatic interaction between the Li cations and the tubular or cage-like B 12 fragments, which is the main reason of such drastic structural changes, resulting in the smallest tubular (Li 2 B 12 ) and cage-like (Li 3 B 12 ) boron structures reported to date. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Surface morphology and molecular bonding of CaCO3 nanocrystallites by gas diffusion method

    NASA Astrophysics Data System (ADS)

    Sulimai, N. H.; Rani, Rozina Abdul; Khusaimi, Z.; Abdullah, S.; Salifairus, M. J.; Alrokayan, Salman; Khan, Haseeb; Rusop, M.

    2018-05-01

    Calcium carbonate with the chemical formula of (CaCO3) is the most abundant element in the world. Its usage on certain applications is largely affected by its properties. The best means to control its properties is through controlled preparation of CaCO3. This study uses diffusion method between the precursors Calcium Chloride and Ammonium Carbonate. Instead of using water, ethanol was used to prepare the salt. Reaction was done in room temperature (RT) for 6h-24h. Smallest average crystallite size measured by FESEM micrograph is 500nm produced by synthesis of CaCO3 reacted for 168 hours. From energy-dispersive X-ray spectrum also indicated the smallest particle size is by CaCO3 reacted for 168 hours. Changes was seen for element Ca at 3.7keV.

  11. The Cognitive Consequences of Emotion Regulation: An ERP Investigation

    PubMed Central

    Deveney, C.M.; Pizzagalli, D.A.

    2008-01-01

    Increasing evidence suggests that emotion regulation (ER) strategies modulate encoding of information presented during regulation; however, no studies have assessed the impact of cognitive reappraisal ER strategies on the processing of stimuli presented after the ER period. Participants in the present study regulated emotions to unpleasant pictures and then judged whether a word was negative or neutral. Electromyographic measures (corrugator supercilli) confirmed that individuals increased and decreased negative affect according to ER condition. Event-related potential analyses revealed smallest N400 amplitudes to negative and neutral words presented after decreasing unpleasant emotions and smallest P300 amplitudes to words presented after increasing unpleasant emotions whereas reaction time data failed to show ER modulations. Results are discussed in the context of the developing ER literature, as well as theories of emotional incongruity (N400) and resource allocation (P300). PMID:18221443

  12. Revealing Early Steps of α2β1 Integrin-mediated Adhesion to Collagen Type I by Using Single-Cell Force Spectroscopy

    PubMed Central

    Taubenberger, Anna; Cisneros, David A.; Friedrichs, Jens; Puech, Pierre-Henri; Muller, Daniel J.

    2007-01-01

    We have characterized early steps of α2β1 integrin-mediated cell adhesion to a collagen type I matrix by using single-cell force spectroscopy. In agreement with the role of α2β1 as a collagen type I receptor, α2β1-expressing Chinese hamster ovary (CHO)-A2 cells spread rapidly on the matrix, whereas α2β1-negative CHO wild-type cells adhered poorly. Probing CHO-A2 cell detachment forces over a contact time range of 600 s revealed a nonlinear adhesion response. During the first 60 s, cell adhesion increased slowly, and forces associated with the smallest rupture events were consistent with the breakage of individual integrin–collagen bonds. Above 60 s, a fraction of cells rapidly switched into an activated adhesion state marked by up to 10-fold increased detachment forces. Elevated overall cell adhesion coincided with a rise of the smallest rupture forces above the value required to break a single-integrin–collagen bond, suggesting a change from single to cooperative receptor binding. Transition into the activated adhesion mode and the increase of the smallest rupture forces were both blocked by inhibitors of actomyosin contractility. We therefore propose a two-step mechanism for the establishment of α2β1-mediated adhesion as weak initial, single-integrin–mediated binding events are superseded by strong adhesive interactions involving receptor cooperativity and actomyosin contractility. PMID:17314408

  13. Using image processing technology and mathematical algorithm in the automatic selection of vocal cord opening and closing images from the larynx endoscopy video.

    PubMed

    Kuo, Chung-Feng Jeffrey; Chu, Yueng-Hsiang; Wang, Po-Chun; Lai, Chun-Yu; Chu, Wen-Lin; Leu, Yi-Shing; Wang, Hsing-Won

    2013-12-01

    The human larynx is an important organ for voice production and respiratory mechanisms. The vocal cord is approximated for voice production and open for breathing. The videolaryngoscope is widely used for vocal cord examination. At present, physicians usually diagnose vocal cord diseases by manually selecting the image of the vocal cord opening to the largest extent (abduction), thus maximally exposing the vocal cord lesion. On the other hand, the severity of diseases such as vocal palsy, atrophic vocal cord is largely dependent on the vocal cord closing to the smallest extent (adduction). Therefore, diseases can be assessed by the image of the vocal cord opening to the largest extent, and the seriousness of breathy voice is closely correlated to the gap between vocal cords when closing to the smallest extent. The aim of the study was to design an automatic vocal cord image selection system to improve the conventional selection process by physicians and enhance diagnosis efficiency. Also, due to the unwanted fuzzy images resulting from examination process caused by human factors as well as the non-vocal cord images, texture analysis is added in this study to measure image entropy to establish a screening and elimination system to effectively enhance the accuracy of selecting the image of the vocal cord closing to the smallest extent. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  14. Aperture effects in squid jet propulsion.

    PubMed

    Staaf, Danna J; Gilly, William F; Denny, Mark W

    2014-05-01

    Squid are the largest jet propellers in nature as adults, but as paralarvae they are some of the smallest, faced with the inherent inefficiency of jet propulsion at a low Reynolds number. In this study we describe the behavior and kinematics of locomotion in 1 mm paralarvae of Dosidicus gigas, the smallest squid yet studied. They swim with hop-and-sink behavior and can engage in fast jets by reducing the size of the mantle aperture during the contraction phase of a jetting cycle. We go on to explore the general effects of a variable mantle and funnel aperture in a theoretical model of jet propulsion scaled from the smallest (1 mm mantle length) to the largest (3 m) squid. Aperture reduction during mantle contraction increases propulsive efficiency at all squid sizes, although 1 mm squid still suffer from low efficiency (20%) because of a limited speed of contraction. Efficiency increases to a peak of 40% for 1 cm squid, then slowly declines. Squid larger than 6 cm must either reduce contraction speed or increase aperture size to maintain stress within maximal muscle tolerance. Ecological pressure to maintain maximum velocity may lead them to increase aperture size, which reduces efficiency. This effect might be ameliorated by nonaxial flow during the refill phase of the cycle. Our model's predictions highlight areas for future empirical work, and emphasize the existence of complex behavioral options for maximizing efficiency at both very small and large sizes.

  15. [Comparisons of manual and automatic refractometry with subjective results].

    PubMed

    Wübbolt, I S; von Alven, S; Hülssner, O; Erb, C

    2006-11-01

    Refractometry is very important in everyday clinical practice. The aim of this study is to compare the precision of three objective methods of refractometry with subjective dioptometry (Phoropter). The objective methods with the smallest deviation to subjective refractometry results are evaluated. The objective methods/instruments used were retinoscopy, Prism Refractometer PR 60 (Rodenstock) and Auto Refractometer RM-A 7000 (Topcon). The results of monocular dioptometry (sphere, cylinder and axis) of each objective method were compared to the results of the subjective method. The examination was carried out on 178 eyes, which were divided into 3 age-related groups: 6 - 12 years (103 eyes), 13 - 18 years (38 eyes) and older than 18 years (37 eyes). All measurements were made in cycloplegia. The smallest standard deviation of the measurement error was found for the Auto Refractometer RM-A 7000. Both the PR 60 and retinoscopy had a clearly higher standard deviation. Furthermore, the RM-A 7000 showed in three and retinoscopy in four of the nine comparisons a significant bias in the measurement error. The Auto Refractometer provides measurements with the smallest deviation compared to the subjective method. Here it has to be taken into account that the measurements for the sphere have an average deviation of + 0.2 dpt. In comparison to retinoscopy the examination of children with the RM-A 7000 is difficult. An advantage of the Auto Refractometer is the fast and easy handling, so that measurements can be performed by medical staff.

  16. Experimental Study of Homogeneous Isotropic Slowly-Decaying Turbulence in Giant Grid-Wind Tunnel Set Up

    NASA Astrophysics Data System (ADS)

    Aliseda, Alberto; Bourgoin, Mickael; Eswirp Collaboration

    2014-11-01

    We present preliminary results from a recent grid turbulence experiment conducted at the ONERA wind tunnel in Modane, France. The ESWIRP Collaboration was conceived to probe the smallest scales of a canonical turbulent flow with very high Reynolds numbers. To achieve this, the largest scales of the turbulence need to be extremely big so that, even with the large separation of scales, the smallest scales would be well above the spatial and temporal resolution of the instruments. The ONERA wind tunnel in Modane (8 m -diameter test section) was chosen as a limit of the biggest large scales achievable in a laboratory setting. A giant inflatable grid (M = 0.8 m) was conceived to induce slowly-decaying homogeneous isotropic turbulence in a large region of the test section, with minimal structural risk. An international team or researchers collected hot wire anemometry, ultrasound anemometry, resonant cantilever anemometry, fast pitot tube anemometry, cold wire thermometry and high-speed particle tracking data of this canonical turbulent flow. While analysis of this large database, which will become publicly available over the next 2 years, has only started, the Taylor-scale Reynolds number is estimated to be between 400 and 800, with Kolmogorov scales as large as a few mm . The ESWIRP Collaboration is formed by an international team of scientists to investigate experimentally the smallest scales of turbulence. It was funded by the European Union to take advantage of the largest wind tunnel in Europe for fundamental research.

  17. Does centralisation of acute obstetric care reduce intrapartum and first-week mortality? An empirical study of over 1 million births in the Netherlands.

    PubMed

    Poeran, Jashvant; Borsboom, Gerard J J M; de Graaf, Johanna P; Birnie, Erwin; Steegers, Eric A P; Mackenbach, Johan P; Bonsel, Gouke J

    2014-07-01

    In this hypothetical analysis with retrospective cohort data (1,160,708 hospital births) we estimated outcome of centralisation of acute obstetric care, i.e., closure of 10 hospitals (out of 99) in The Netherlands. The main outcome was predicted intrapartum and first-week mortality (further referred to as neonatal mortality) for several subgroups of patients affected by two centralisation scenarios: (1) closure of the 10 smallest hospitals; (2) closure of the 10 smallest hospitals, but avoiding adjacent closures. Predictions followed from regression coefficients from a multilevel logistic regression model. Scenario 1 resulted in doubled travel time, and 10% increased mortality (210 [0.34%] to 231 [0.38%] cases). Scenario 2 showed less effect on mortality (268 [0.33%] to 259 [0.32%] cases) and travel time. Heterogeneity in hospital organisational features caused simultaneous improvement and deterioration of predicted neonatal mortality. Consequences vary for subgroups. We demonstrate that (in The Netherlands) centralisation of acute obstetric care according to the 'closure-of-the-smallest-rule' yields suboptimal outcomes. In order to develop an optimal strategy one would need to consider all positive and negative effects, e.g., organisational heterogeneity of closing and surviving hospitals, differential effects for patient subgroups, increased travel time, and financial aspects. The provided framework may be beneficial for other countries considering centralisation of acute obstetric care. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  18. Influence of various force fields in estimating the binding affinity of acetylcholinesterase inhibitors using fast pulling of ligand scheme

    NASA Astrophysics Data System (ADS)

    Tam, Nguyen Minh; Vu, Khanh B.; Vu, Van V.; Ngo, Son Tung

    2018-06-01

    Acetylcholinesterase (AChE) is considered as one of the most favored drug targets for Alzheimer's disease. The effects of different force fields (FFs) on ranking affinity of acetylcholinesterase inhibitors were obtained using the fast pulling of ligand (FPL) method in steered-molecular dynamics (SMD) simulations. GROMOS, AMBER, CHARMM, and OPLS-AA FFs were investigated in this work. The pulling work derived with GROMOS FF has the strongest correlation and smallest error compared with experimental binding affinity. Moreover, the CPU consumption in the calculations using GROMOS FF is the lowest, which could allow us to rank affinity of a large number of AChE ligands.

  19. Gas dynamics in strong centrifugal fields

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bogovalov, S.V.; Kislov, V.A.; Tronin, I.V.

    2015-03-10

    Dynamics of waves generated by scopes in gas centrifuges (GC) for isotope separation is considered. The centrifugal acceleration in the GC reaches values of the order of 106g. The centrifugal and Coriolis forces modify essentially the conventional sound waves. Three families of the waves with different polarisation and dispersion exist in these conditions. Dynamics of the flow in the model GC Iguasu is investigated numerically. Comparison of the results of the numerical modelling of the wave dynamics with the analytical predictions is performed. New phenomena of the resonances in the GC is found. The resonances occur for the waves polarizedmore » along the rotational axis having the smallest dumping due to the viscosity.« less

  20. Measurement of acoustic attenuation in South Pole ice

    NASA Astrophysics Data System (ADS)

    IceCube Collaboration; Abbasi, R.; Abdou, Y.; Abu-Zayyad, T.; Adams, J.; Aguilar, J. A.; Ahlers, M.; Andeen, K.; Auffenberg, J.; Bai, X.; Baker, M.; Barwick, S. W.; Bay, R.; Bazo Alba, J. L.; Beattie, K.; Beatty, J. J.; Bechet, S.; Becker, J. K.; Becker, K.-H.; Benabderrahmane, M. L.; Berdermann, J.; Berghaus, P.; Berley, D.; Bernardini, E.; Bertrand, D.; Besson, D. Z.; Bissok, M.; Blaufuss, E.; Boersma, D. J.; Bohm, C.; Böser, S.; Botner, O.; Bradley, L.; Braun, J.; Buitink, S.; Carson, M.; Chirkin, D.; Christy, B.; Clem, J.; Clevermann, F.; Cohen, S.; Colnard, C.; Cowen, D. F.; D'Agostino, M. V.; Danninger, M.; de Clercq, C.; Demirörs, L.; Depaepe, O.; Descamps, F.; Desiati, P.; de Vries-Uiterweerd, G.; Deyoung, T.; Díaz-Vélez, J. C.; Dreyer, J.; Dumm, J. P.; Duvoort, M. R.; Ehrlich, R.; Eisch, J.; Ellsworth, R. W.; Engdegård, O.; Euler, S.; Evenson, P. A.; Fadiran, O.; Fazely, A. R.; Feusels, T.; Filimonov, K.; Finley, C.; Foerster, M. M.; Fox, B. D.; Franckowiak, A.; Franke, R.; Gaisser, T. K.; Gallagher, J.; Ganugapati, R.; Geisler, M.; Gerhardt, L.; Gladstone, L.; Glüsenkamp, T.; Goldschmidt, A.; Goodman, J. A.; Grant, D.; Griesel, T.; Groß, A.; Grullon, S.; Gunasingha, R. M.; Gurtner, M.; Gustafsson, L.; Ha, C.; Hallgren, A.; Halzen, F.; Han, K.; Hanson, K.; Helbing, K.; Herquet, P.; Hickford, S.; Hill, G. C.; Hoffman, K. D.; Homeier, A.; Hoshina, K.; Hubert, D.; Huelsnitz, W.; Hülß, J.-P.; Hulth, P. O.; Hultqvist, K.; Hussain, S.; Imlay, R. L.; Ishihara, A.; Jacobsen, J.; Japaridze, G. S.; Johansson, H.; Joseph, J. M.; Kampert, K.-H.; Kappes, A.; Karg, T.; Karle, A.; Kelley, J. L.; Kemming, N.; Kenny, P.; Kiryluk, J.; Kislat, F.; Klein, S. R.; Knops, S.; Köhne, J.-H.; Kohnen, G.; Kolanoski, H.; Köpke, L.; Koskinen, D. J.; Kowalski, M.; Kowarik, T.; Krasberg, M.; Krings, T.; Kroll, G.; Kuehn, K.; Kuwabara, T.; Labare, M.; Lafebre, S.; Laihem, K.; Landsman, H.; Lauer, R.; Lehmann, R.; Lennarz, D.; Lünemann, J.; Madsen, J.; Majumdar, P.; Maruyama, R.; Mase, K.; Matis, H. S.; Matusik, M.; Meagher, K.; Merck, M.; Mészáros, P.; Meures, T.; Middell, E.; Milke, N.; Montaruli, T.; Morse, R.; Movit, S. M.; Nahnhauer, R.; Nam, J. W.; Naumann, U.; Nießen, P.; Nygren, D. R.; Odrowski, S.; Olivas, A.; Olivo, M.; Ono, M.; Panknin, S.; Paul, L.; Pérez de Los Heros, C.; Petrovic, J.; Piegsa, A.; Pieloth, D.; Porrata, R.; Posselt, J.; Price, P. B.; Prikockis, M.; Przybylski, G. T.; Rawlins, K.; Redl, P.; Resconi, E.; Rhode, W.; Ribordy, M.; Rizzo, A.; Rodrigues, J. P.; Roth, P.; Rothmaier, F.; Rott, C.; Roucelle, C.; Ruhe, T.; Rutledge, D.; Ruzybayev, B.; Ryckbosch, D.; Sander, H.-G.; Sarkar, S.; Schatto, K.; Schlenstedt, S.; Schmidt, T.; Schneider, D.; Schukraft, A.; Schultes, A.; Schulz, O.; Schunck, M.; Seckel, D.; Semburg, B.; Seo, S. H.; Sestayo, Y.; Seunarine, S.; Silvestri, A.; Slipak, A.; Spiczak, G. M.; Spiering, C.; Stamatikos, M.; Stanev, T.; Stephens, G.; Stezelberger, T.; Stokstad, R. G.; Stoyanov, S.; Strahler, E. A.; Straszheim, T.; Sullivan, G. W.; Swillens, Q.; Taboada, I.; Tamburro, A.; Tarasova, O.; Tepe, A.; Ter-Antonyan, S.; Tilav, S.; Toale, P. A.; Tosi, D.; Turčan, D.; van Eijndhoven, N.; Vandenbroucke, J.; van Overloop, A.; van Santen, J.; Voigt, B.; Walck, C.; Waldenmaier, T.; Wallraff, M.; Walter, M.; Wendt, C.; Westerhoff, S.; Whitehorn, N.; Wiebe, K.; Wiebusch, C. H.; Wikström, G.; Williams, D. R.; Wischnewski, R.; Wissing, H.; Woschnagg, K.; Xu, C.; Xu, X. W.; Yanez, J. P.; Yodh, G.; Yoshida, S.; Zarzhitsky, P.; IceCube Collaboration

    2011-01-01

    Using the South Pole Acoustic Test Setup (SPATS) and a retrievable transmitter deployed in holes drilled for the IceCube experiment, we have measured the attenuation of acoustic signals by South Pole ice at depths between 190 m and 500 m. Three data sets, using different acoustic sources, have been analyzed and give consistent results. The method with the smallest systematic uncertainties yields an amplitude attenuation coefficient α = 3.20 ± 0.57 km-1 between 10 and 30 kHz, considerably larger than previous theoretical estimates. Expressed as an attenuation length, the analyses give a consistent result for λ ≡ 1/α of ˜300 m with 20% uncertainty. No significant depth or frequency dependence has been found.

  1. Effects of etchants in the transfer of chemical vapor deposited graphene

    NASA Astrophysics Data System (ADS)

    Wang, M.; Yang, E. H.; Vajtai, R.; Kono, J.; Ajayan, P. M.

    2018-05-01

    The quality of graphene can be strongly modified during the transfer process following chemical vapor deposition (CVD) growth. Here, we transferred CVD-grown graphene from a copper foil to a SiO2/Si substrate using wet etching with four different etchants: HNO3, FeCl3, (NH4)2S2O8, and a commercial copper etchant. We then compared the quality of graphene after the transfer process in terms of surface modifications, pollutions (residues and contaminations), and electrical properties (mobility and density). Our tests and analyses showed that the commercial copper etchant provides the best structural integrity, the least amount of residues, and the smallest doping carrier concentration.

  2. Decay rates of magnetic modes below the threshold of a turbulent dynamo.

    PubMed

    Herault, J; Pétrélis, F; Fauve, S

    2014-04-01

    We measure the decay rates of magnetic field modes in a turbulent flow of liquid sodium below the dynamo threshold. We observe that turbulent fluctuations induce energy transfers between modes with different symmetries (dipolar and quadrupolar). Using symmetry properties, we show how to measure the decay rate of each mode without being restricted to the one with the smallest damping rate. We observe that the respective values of the decay rates of these modes depend on the shape of the propellers driving the flow. Dynamical regimes, including field reversals, are observed only when the modes are both nearly marginal. This is in line with a recently proposed model.

  3. Real and hypothetical rewards

    PubMed Central

    Locey, Matthew L.; Jones, Bryan A.; Rachlin, Howard

    2012-01-01

    Laboratory studies of choice and decision making among real monetary rewards typically use smaller real rewards than those common in real life. When laboratory rewards are large, they are almost always hypothetical. In applying laboratory results meaningfully to real-life situations, it is important to know the extent to which choices among hypothetical rewards correspond to choices among real rewards and whether variation of the magnitude of hypothetical rewards affects behavior in meaningful ways. The present study compared real and hypothetical monetary rewards in two experiments. In Experiment 1, participants played a temporal discounting game that incorporates the logic of a repeated prisoner’s-dilemma (PD) type game versus tit-for-tat; choice of one alternative (“defection” in PD terminology) resulted in a small-immediate reward; choice of the other alternative (“cooperation” in PD terminology) resulted in a larger reward delayed until the following trial. The larger-delayed reward was greater for half of the groups than for the other half. Rewards also differed in type across groups: multiples of real nickels, hypothetical nickels or hypothetical hundred-dollar bills. All groups significantly increased choice of the larger delayed reward over the 40 trials of the experiment. Over the last 10 trials, cooperation was significantly higher when the difference between larger and smaller hypothetical rewards was greater. Reward type (real or hypothetical) made no significant difference in cooperation. In Experiment 2, real and hypothetical rewards were compared in social discounting – the decrease in value to the giver of a reward as social distance increases to the receiver of the reward. Social discount rates were well described by a hyperbolic function. Discounting rates for real and hypothetical rewards did not significantly differ. These results add to the evidence that results of experiments with hypothetical rewards validly apply in everyday life. PMID:22582110

  4. Detector to detector corrections: a comprehensive experimental study of detector specific correction factors for beam output measurements for small radiotherapy beams.

    PubMed

    Azangwe, Godfrey; Grochowska, Paulina; Georg, Dietmar; Izewska, Joanna; Hopfgartner, Johannes; Lechner, Wolfgang; Andersen, Claus E; Beierholm, Anders R; Helt-Hansen, Jakob; Mizuno, Hideyuki; Fukumura, Akifumi; Yajima, Kaori; Gouldstone, Clare; Sharpe, Peter; Meghzifene, Ahmed; Palmans, Hugo

    2014-07-01

    The aim of the present study is to provide a comprehensive set of detector specific correction factors for beam output measurements for small beams, for a wide range of real time and passive detectors. The detector specific correction factors determined in this study may be potentially useful as a reference data set for small beam dosimetry measurements. Dose response of passive and real time detectors was investigated for small field sizes shaped with a micromultileaf collimator ranging from 0.6 × 0.6 cm(2) to 4.2 × 4.2 cm(2) and the measurements were extended to larger fields of up to 10 × 10 cm(2). Measurements were performed at 5 cm depth, in a 6 MV photon beam. Detectors used included alanine, thermoluminescent dosimeters (TLDs), stereotactic diode, electron diode, photon diode, radiophotoluminescent dosimeters (RPLDs), radioluminescence detector based on carbon-doped aluminium oxide (Al2O3:C), organic plastic scintillators, diamond detectors, liquid filled ion chamber, and a range of small volume air filled ionization chambers (volumes ranging from 0.002 cm(3) to 0.3 cm(3)). All detector measurements were corrected for volume averaging effect and compared with dose ratios determined from alanine to derive a detector correction factors that account for beam perturbation related to nonwater equivalence of the detector materials. For the detectors used in this study, volume averaging corrections ranged from unity for the smallest detectors such as the diodes, 1.148 for the 0.14 cm(3) air filled ionization chamber and were as high as 1.924 for the 0.3 cm(3) ionization chamber. After applying volume averaging corrections, the detector readings were consistent among themselves and with alanine measurements for several small detectors but they differed for larger detectors, in particular for some small ionization chambers with volumes larger than 0.1 cm(3). The results demonstrate how important it is for the appropriate corrections to be applied to give consistent and accurate measurements for a range of detectors in small beam geometry. The results further demonstrate that depending on the choice of detectors, there is a potential for large errors when effects such as volume averaging, perturbation and differences in material properties of detectors are not taken into account. As the commissioning of small fields for clinical treatment has to rely on accurate dose measurements, the authors recommend the use of detectors that require relatively little correction, such as unshielded diodes, diamond detectors or microchambers, and solid state detectors such as alanine, TLD, Al2O3:C, or scintillators.

  5. Refractory black carbon at the Whistler Peak High Elevation Research Site - Measurements and simulations

    NASA Astrophysics Data System (ADS)

    Hanna, Sarah J.; Xu, Jun-Wei; Schroder, Jason C.; Wang, Qiaoqiao; McMeeking, Gavin R.; Hayden, Katherine; Leaitch, W. Richard; Macdonald, AnneMarie; von Salzen, Knut; Martin, Randall V.; Bertram, Allan K.

    2018-05-01

    Measurements of black carbon at remote and high altitude locations provide an important constraint for models. Here we present six months of refractory black carbon (rBC) data collected in July-August of 2009, June-July of 2010, and April-May of 2012 using a single particle soot photometer (SP2) at the remote Whistler High Elevation Research Site in the Coast Mountains of British Columbia (50.06°N, 122.96°W, 2182 m a.m.s.l). In order to reduce regional boundary layer influences, only measurements collected during the night (2000-0800 PST) were considered. Times impacted by local biomass burning were removed from the data set, as were periods of in-cloud sampling. Back trajectories and back trajectory cluster analysis were used to classify the sampled air masses as Southern Pacific, Northern Pacific, Western Pacific/Asian, or Northern Canadian in origin. The largest rBC mass median diameter (182 nm) was seen for air masses in the Southern Pacific cluster, and the smallest (156 nm) was seen for air masses in the Western Pacific/Asian cluster. Considering all the clusters, the median mass concentration of rBC was 25.0 ± 7.6 ng/m3-STP. The Northern Pacific, Southern Pacific, Western Pacific/Asian, and Northern Canada clusters had median mass concentrations of 25.0 ± 7.6, 21.3 ± 6.9, 25.0 ± 7.9, and 40.6 ± 12.9 ng/m3-STP, respectively. We compared these measurements with simulations from the global chemical transport model GEOS-Chem. The default GEOS-Chem simulations overestimated the median rBC mass concentrations for the different clusters by a factor of 1.2-2.2. The largest difference was observed for the Northern Pacific cluster (factor of 2.2) and the smallest difference was observed for the Northern Canada cluster (factor of 1.2). A sensitivity simulation that excluded Vancouver emissions still overestimated the median rBC mass concentrations for the different clusters by a factor of 1.1-2.0. After implementation of a revised wet scavenging scheme, the simulations overestimated the median rBC mass concentrations for the different clusters by a factor of 1.0-2.0.

  6. Randomized crossover clinical trial of real and sham peripheral prism glasses for hemianopia

    PubMed Central

    Bowers, Alex R.; Keeney, Karen; Peli, Eli

    2013-01-01

    Objective To evaluate the efficacy of real relative to sham peripheral prism glasses for patients with complete homonymous hemianopia and without visual neglect. Methods Patients recruited at 13 clinics were allocated by minimization into a double-masked, crossover trial with two groups. One group received real (57Δ) oblique and sham (≤ 5Δ) horizontal prisms; the other received real horizontal and sham oblique, in counterbalanced order. A masked data collector at each clinic administered questionnaires after each 4-week crossover period. Main outcome measure The primary outcome was the overall difference, across the two periods of the crossover, between the proportion of participants who wanted to continue with (said “yes” to) real prisms and the proportion who said yes to sham prisms. The secondary outcome was the difference in perceived mobility improvement between real and sham prisms. Results Of 73 patients randomized, 61 completed the crossover. A significantly higher proportion said yes to real than sham prisms (64% vs. 36%; odds ratio 5.3, 95% CI 1.8 to 21.0). Participants who continued wear after 6 months reported greater improvement in mobility with real than sham prisms at crossover end (p=0.002); participants who discontinued wear reported no difference. Conclusion Real peripheral prism glasses were more helpful for obstacle avoidance when walking than sham glasses, with no differences between the horizontal and oblique designs. Applications to clinical practice Peripheral prism glasses provide a simple and inexpensive mobility rehabilitation intervention for hemianopia. PMID:24201760

  7. College Students’ Perceived Differences Between the Terms Real Meal, Meal, and Snack

    PubMed Central

    Banna, Jinan; Richards, Rickelle; Brown, Lora Beth

    2017-01-01

    Objective To assess qualitatively and quantitatively college students’ perceived differences between a real meal, meal, and snack. Design A descriptive study design was used to administer an 11-item online survey to college students. Setting Two university campuses in the western US. Participants Pilot testing was conducted with 20 students. The final survey was completed by 628 ethnically diverse students. Main Outcome Measures Students’ perceptions of the terms real meal, meal, and snack. Analysis Three researchers coded the data independently, reconciled differences via conference calls, and agreed on a final coding scheme. Data were reevaluated based on the coding scheme. Means, frequencies, Pearson chi-square, and t test statistics were used. Results More than half of students perceived a difference between the terms real meal and meal. Most (97.6%) perceived a difference between the terms meal and snack. A marked difference in the way students defined these terms was evident, with a real meal deemed nutritious and healthy and meeting dietary recommendations, compared with meals, which were considered anything to eat. Conclusions and Implications These findings suggest that the term real meal may provide nutrition educators with a simple phrase to use in educational campaigns to promote healthful food intake among college students. PMID:27993555

  8. Differences in Behavior and Brain Activity during Hypothetical and Real Choices.

    PubMed

    Camerer, Colin; Mobbs, Dean

    2017-01-01

    Real behaviors are binding consequential commitments to a course of action, such as harming another person, buying an Apple watch, or fleeing from danger. Cognitive scientists are generally interested in the psychological and neural processes that cause such real behavior. However, for practical reasons, many scientific studies measure behavior using only hypothetical or imagined stimuli. Generalizing from such studies to real behavior implicitly assumes that the processes underlying the two types of behavior are similar. We review evidence of similarity and differences in hypothetical and real mental processes. In many cases, hypothetical choice tasks give an incomplete picture of brain circuitry that is active during real choice. Copyright © 2016. Published by Elsevier Ltd.

  9. Wide-field reflective scanning optical systems

    NASA Technical Reports Server (NTRS)

    Abel, I. R.

    1973-01-01

    Catoptric optical scanning system provides relatively fast line-scan rate for two-dimensional coverage. Rapid scan rates require low focal ratios between components and smallest possible masses. System is relatively free from monochromatic defects and chromatic aberrations.

  10. An expanded role for river networks

    Treesearch

    Jonathan P. Benstead; David S. Leigh

    2012-01-01

    Estimates of stream and river area have relied on observations at coarse resolution. Consideration of the smallest and most dynamic streams could reveal a greater role for river networks in global biogeochemical cycling than previously thought.

  11. 28 CFR 63.4 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... flooding would be too great. (g) Facility—any man-made or man-placed item other than a structure. (h) Flood... reduce to the smallest possible amount or degree. (m) One percent chance flood—the flood having one...

  12. Still from Red Spot Movie

    NASA Image and Video Library

    2000-11-21

    This image is one of seven from the narrow-angle camera on NASA Cassini spacecraft assembled as a brief movie of cloud movements on Jupiter. The smallest features visible are about 500 kilometers about 300 miles across.

  13. The Birth of the Cosmic Frontier

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kolb, Rocky; Turner, Mike

    Scientists Rocky Kolb and Mike Turner recount the time they first proposed that Fermilab – dedicated to the study of the universe's smallest constituents — expand its program to include the stars, galaxies and the cosmos.

  14. Computer Calculation of Fire Danger

    Treesearch

    William A. Main

    1969-01-01

    This paper describes a computer program that calculates National Fire Danger Rating Indexes. fuel moisture, buildup index, and drying factor are also available. The program is written in FORTRAN and is usable on even the smallest compiler.

  15. Hypsometry, volume and physiography of the Arctic Ocean and their paleoceanographic implications

    NASA Astrophysics Data System (ADS)

    Jakobsson, M.; Macnab, R.; Grantz, A.; Kristoffersen, Y.

    2003-04-01

    Recent analyses of the International Bathymetric Chart of the Arctic Ocean (IBCAO) grid model include: Hypsometry (the distribution of surface area at various depths); ocean volume distribution; and physiographic provinces [Jakobsson 2002; Jakobsson et al., in press]. The present paper summarizes the main results from these recent studies and expands on the paleoceanographic implications for the Arctic Ocean, which in this work is defined as the broad continental shelves of the Barents, Kara, Laptev, East Siberian and Chukchi Seas, the White Sea and the narrow continental shelves of the Beaufort Sea, the Arctic continental margins off the Canadian Arctic Archipelago and northern Greenland. This, the World's smallest ocean, is a virtually land-locked ocean that makes up merely 2.6 % of the area, and 1.0 % of the volume, of the entire World Ocean. The continental shelf area, from the coastline out to the shelf break, comprises as much as 52.9 % of the total area in the Arctic Ocean, which is significantly larger in comparison to the rest of the world oceans where the proportion of shelves, from the coastline out to the foot of the continental slope, only ranges between about 9.1 % and 17.7 %. In Jakobsson [2002], the seafloor area and water volume were calculated for different depths starting from the present sea level and progressing in increments of 10 m to a depth of 500 m, and in increments of 50 m from 550 m down to the deepest depth within each of the analyzed Arctic Ocean seas. Hypsometric curves expressed as simple histograms of the frequencies in different depth bins were presented, along with depth plotted against cumulative area for each of the analyzed seas. The derived hypsometric curves show that most of the Arctic Ocean shelf seas besides the Barents Sea, Beaufort Sea and the shelf off northern Greenland have a similar shape with the largest seafloor area between 0 and 50 m. The East Siberian and Laptev seas, in particular, show area distributions concentrated in this shallow depth range, and together with the Chukchi Sea they form a large flat shallow shelf province comprising as much as 22 % of the entire Arctic Ocean area, but only 1 % of the volume. Given this vast shelf area it may be speculated that the Arctic Ocean circulation is more sensitive to eustatic sea level changes compared to the other world oceans. For example, during the LGM when the sea level was ca 120 m lower than today most, if not all, of the Arctic Ocean shelf region could not play a role in the ocean circulation. Besides being the world's smallest ocean with the by far largest shelf area in proportion to its size, the Arctic Ocean is unique in terms of its physiographic setting. The Fram Strait is the only real break in the barrier of vast continental shelves enclosing the Arctic Ocean. The second largest physiographic province after the continental shelves consists of ridges, which is in contrast to the rest of the World's oceans where abyssal plains dominate. As much as 15.8 % of the area is underlain by ridges indicating the profound effect they have on ocean circulation. Jakobsson, M., Grantz, A., Kristoffersen, Y., and Macnab, R., in press, Physiographic Provinces of the Arctic Ocean, GSA Bulletin. Jakobsson, M., 2002, Hypsometry and volume of the Arctic Ocean and its constituent’s seas, Geochemistry Geophysics Geosystems, v. 3, no. 2.

  16. Property Analysis of the Real-Time Uncalibrated Phase Delay Product Generated by Regional Reference Stations and Its Influence on Precise Point Positioning Ambiguity Resolution

    PubMed Central

    Zhang, Yong; Wang, Qing; Jiang, Xinyuan

    2017-01-01

    The real-time estimation of the wide-lane and narrow-lane Uncalibrated Phase Delay (UPD) of satellites is realized by real-time data received from regional reference station networks; The properties of the real-time UPD product and its influence on real-time precise point positioning ambiguity resolution (RTPPP-AR) are experimentally analyzed according to real-time data obtained from the regional Continuously Operating Reference Stations (CORS) network located in Tianjin, Shanghai, Hong Kong, etc. The results show that the real-time wide-lane and narrow-lane UPD products differ significantly from each other in time-domain characteristics; the wide-lane UPDs have daily stability, with a change rate of less than 0.1 cycle/day, while the narrow-lane UPDs have short-term stability, with significant change in one day. The UPD products generated by different regional networks have obvious spatial characteristics, thus significantly influencing RTPPP-AR: the adoption of real-time UPD products employing the sparse stations in the regional network for estimation is favorable for improving the regional RTPPP-AR up to 99%; the real-time UPD products of different regional networks slightly influence PPP-AR positioning accuracy. After ambiguities are successfully fixed, the real-time dynamic RTPPP-AR positioning accuracy is better than 3 cm in the plane and 8 cm in the upward direction. PMID:28534844

  17. Property Analysis of the Real-Time Uncalibrated Phase Delay Product Generated by Regional Reference Stations and Its Influence on Precise Point Positioning Ambiguity Resolution.

    PubMed

    Zhang, Yong; Wang, Qing; Jiang, Xinyuan

    2017-05-19

    The real-time estimation of the wide-lane and narrow-lane Uncalibrated Phase Delay (UPD) of satellites is realized by real-time data received from regional reference station networks; The properties of the real-time UPD product and its influence on real-time precise point positioning ambiguity resolution (RTPPP-AR) are experimentally analyzed according to real-time data obtained from the regional Continuously Operating Reference Stations (CORS) network located in Tianjin, Shanghai, Hong Kong, etc. The results show that the real-time wide-lane and narrow-lane UPD products differ significantly from each other in time-domain characteristics; the wide-lane UPDs have daily stability, with a change rate of less than 0.1 cycle/day, while the narrow-lane UPDs have short-term stability, with significant change in one day. The UPD products generated by different regional networks have obvious spatial characteristics, thus significantly influencing RTPPP-AR: the adoption of real-time UPD products employing the sparse stations in the regional network for estimation is favorable for improving the regional RTPPP-AR up to 99%; the real-time UPD products of different regional networks slightly influence PPP-AR positioning accuracy. After ambiguities are successfully fixed, the real-time dynamic RTPPP-AR positioning accuracy is better than 3 cm in the plane and 8 cm in the upward direction.

  18. Robust clustering of languages across Wikipedia growth

    NASA Astrophysics Data System (ADS)

    Ban, Kristina; Perc, Matjaž; Levnajić, Zoran

    2017-10-01

    Wikipedia is the largest existing knowledge repository that is growing on a genuine crowdsourcing support. While the English Wikipedia is the most extensive and the most researched one with over 5 million articles, comparatively little is known about the behaviour and growth of the remaining 283 smaller Wikipedias, the smallest of which, Afar, has only one article. Here, we use a subset of these data, consisting of 14 962 different articles, each of which exists in 26 different languages, from Arabic to Ukrainian. We study the growth of Wikipedias in these languages over a time span of 15 years. We show that, while an average article follows a random path from one language to another, there exist six well-defined clusters of Wikipedias that share common growth patterns. The make-up of these clusters is remarkably robust against the method used for their determination, as we verify via four different clustering methods. Interestingly, the identified Wikipedia clusters have little correlation with language families and groups. Rather, the growth of Wikipedia across different languages is governed by different factors, ranging from similarities in culture to information literacy.

  19. Robust clustering of languages across Wikipedia growth.

    PubMed

    Ban, Kristina; Perc, Matjaž; Levnajić, Zoran

    2017-10-01

    Wikipedia is the largest existing knowledge repository that is growing on a genuine crowdsourcing support. While the English Wikipedia is the most extensive and the most researched one with over 5 million articles, comparatively little is known about the behaviour and growth of the remaining 283 smaller Wikipedias, the smallest of which, Afar, has only one article. Here, we use a subset of these data, consisting of 14 962 different articles, each of which exists in 26 different languages, from Arabic to Ukrainian. We study the growth of Wikipedias in these languages over a time span of 15 years. We show that, while an average article follows a random path from one language to another, there exist six well-defined clusters of Wikipedias that share common growth patterns. The make-up of these clusters is remarkably robust against the method used for their determination, as we verify via four different clustering methods. Interestingly, the identified Wikipedia clusters have little correlation with language families and groups. Rather, the growth of Wikipedia across different languages is governed by different factors, ranging from similarities in culture to information literacy.

  20. Robust clustering of languages across Wikipedia growth

    PubMed Central

    Ban, Kristina; Levnajić, Zoran

    2017-01-01

    Wikipedia is the largest existing knowledge repository that is growing on a genuine crowdsourcing support. While the English Wikipedia is the most extensive and the most researched one with over 5 million articles, comparatively little is known about the behaviour and growth of the remaining 283 smaller Wikipedias, the smallest of which, Afar, has only one article. Here, we use a subset of these data, consisting of 14 962 different articles, each of which exists in 26 different languages, from Arabic to Ukrainian. We study the growth of Wikipedias in these languages over a time span of 15 years. We show that, while an average article follows a random path from one language to another, there exist six well-defined clusters of Wikipedias that share common growth patterns. The make-up of these clusters is remarkably robust against the method used for their determination, as we verify via four different clustering methods. Interestingly, the identified Wikipedia clusters have little correlation with language families and groups. Rather, the growth of Wikipedia across different languages is governed by different factors, ranging from similarities in culture to information literacy. PMID:29134106

Top