Determination of the optimal level for combining area and yield estimates
NASA Technical Reports Server (NTRS)
Bauer, M. E. (Principal Investigator); Hixson, M. M.; Jobusch, C. D.
1981-01-01
Several levels of obtaining both area and yield estimates of corn and soybeans in Iowa were considered: county, refined strata, refined/split strata, crop reporting district, and state. Using the CCEA model form and smoothed weather data, regression coefficients at each level were derived to compute yield and its variance. Variances were also computed with stratum level. The variance of the yield estimates was largest at the state and smallest at the county level for both crops. The refined strata had somewhat larger variances than those associated with the refined/split strata and CRD. For production estimates, the difference in standard deviations among levels was not large for corn, but for soybeans the standard deviation at the state level was more than 50% greater than for the other levels. The refined strata had the smallest standard deviations. The county level was not considered in evaluation of production estimates due to lack of county area variances.
[Comparisons of manual and automatic refractometry with subjective results].
Wübbolt, I S; von Alven, S; Hülssner, O; Erb, C
2006-11-01
Refractometry is very important in everyday clinical practice. The aim of this study is to compare the precision of three objective methods of refractometry with subjective dioptometry (Phoropter). The objective methods with the smallest deviation to subjective refractometry results are evaluated. The objective methods/instruments used were retinoscopy, Prism Refractometer PR 60 (Rodenstock) and Auto Refractometer RM-A 7000 (Topcon). The results of monocular dioptometry (sphere, cylinder and axis) of each objective method were compared to the results of the subjective method. The examination was carried out on 178 eyes, which were divided into 3 age-related groups: 6 - 12 years (103 eyes), 13 - 18 years (38 eyes) and older than 18 years (37 eyes). All measurements were made in cycloplegia. The smallest standard deviation of the measurement error was found for the Auto Refractometer RM-A 7000. Both the PR 60 and retinoscopy had a clearly higher standard deviation. Furthermore, the RM-A 7000 showed in three and retinoscopy in four of the nine comparisons a significant bias in the measurement error. The Auto Refractometer provides measurements with the smallest deviation compared to the subjective method. Here it has to be taken into account that the measurements for the sphere have an average deviation of + 0.2 dpt. In comparison to retinoscopy the examination of children with the RM-A 7000 is difficult. An advantage of the Auto Refractometer is the fast and easy handling, so that measurements can be performed by medical staff.
Min and Max Exponential Extreme Interval Values and Statistics
ERIC Educational Resources Information Center
Jance, Marsha; Thomopoulos, Nick
2009-01-01
The extreme interval values and statistics (expected value, median, mode, standard deviation, and coefficient of variation) for the smallest (min) and largest (max) values of exponentially distributed variables with parameter ? = 1 are examined for different observation (sample) sizes. An extreme interval value g[subscript a] is defined as a…
The joint use of the tangential electric field and surface Laplacian in EEG classification.
Carvalhaes, C G; de Barros, J Acacio; Perreau-Guimaraes, M; Suppes, P
2014-01-01
We investigate the joint use of the tangential electric field (EF) and the surface Laplacian (SL) derivation as a method to improve the classification of EEG signals. We considered five classification tasks to test the validity of such approach. In all five tasks, the joint use of the components of the EF and the SL outperformed the scalar potential. The smallest effect occurred in the classification of a mental task, wherein the average classification rate was improved by 0.5 standard deviations. The largest effect was obtained in the classification of visual stimuli and corresponded to an improvement of 2.1 standard deviations.
Using walker during walking: a pilot study for health elder.
Po-Chan, Yeh; Cherng-Yee, Leung
2012-01-01
Walker operation completely relies on the walker handle, however most marketed walkers possess two horizontal handles. Several researchers have suggested that horizontal handles might lead to wrist injury. Therefore, the purpose of this study is to assess the relevant design aspects of walker for elderly people. 28 elders participated in this study; when the experiment was started, subject walked on the tile for 3 meter distance twice by using walker. Data for analysis were selected at the corresponding wrist deviation and vertical force. The results showed that during walker using, the mean wrist deviation was greater than zero. The largest vertical force is significantly larger than the smallest one, and different wrist deviation occurred at three phases, the largest wrist deviation while raising walker is larger than the smallest one, however, no significant different was found between the largest and smallest wrist deviation while pressing walker. No significant correlation occurred between weight and wrist deviation. The correlation between weight and vertical force was significantly positive. With wrist deviation walker use may cause injury to upper-limb, however wrists remain in a neutral position during hand movement to prevent damage. The findings of this study should improve the design of walker handles to reduce the wrist deviations of users.
Brogårdh, Christina; Lexell, Jan
2016-05-01
A new 13-item rating scale, the Self-Reported Impairments in Persons with Late Effects of Polio (SIPP), has been developed. The SIPP has been analyzed using the Rasch method and has shown good construct validity and internal consistency. To establish its clinical utility, further evaluation of its psychometric properties is needed. To evaluate the test-retest reliability of the SIPP and to define limits for the smallest change that indicates a real change, both for a group of persons and a single individual. A postal survey. University Hospital. Fifty-one persons (31 men and 20 women; mean age, 72 years) with clinically verified late effects of polio. Not applicable. The participants completed the SIPP twice, 2 weeks apart. The response frequencies at test occasion 1 (T1) and test occasion 2 (T2) were calculated. Test-retest reliability was analyzed using the percentage agreement of each item, the intraclass correlation coefficient, and the mean difference between the test occasions (đ), together with the 95% confidence intervals for đ, the standard error of measurement, the smallest real difference, and a Bland-Altman plot. The percentage agreement (ie, the same scoring at both test occasions) was >70% for 10 of 13 items. The mean score (standard deviation) was 27.9 (5.7) points at T1 and 28.2 (6.0) points at T2, with no systematic difference between the test occasions. The intraclass correlation coefficient was 0.88, the standard error of measurement (the smallest change for a group of persons) was 2.0 points, and the smallest real difference (the smallest change for a single individual) was 5.6 points, respectively. The SIPP is a reliable rating scale in persons with late effects of polio and can be used to evaluate effects of rehabilitation interventions and changes of perceived impairments over time both for a group of persons and for a single individual. Copyright © 2016 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Gilliom, Robert J.; Helsel, Dennis R.
1986-01-01
A recurring difficulty encountered in investigations of many metals and organic contaminants in ambient waters is that a substantial portion of water sample concentrations are below limits of detection established by analytical laboratories. Several methods were evaluated for estimating distributional parameters for such censored data sets using only uncensored observations. Their reliabilities were evaluated by a Monte Carlo experiment in which small samples were generated from a wide range of parent distributions and censored at varying levels. Eight methods were used to estimate the mean, standard deviation, median, and interquartile range. Criteria were developed, based on the distribution of uncensored observations, for determining the best performing parameter estimation method for any particular data set. The most robust method for minimizing error in censored-sample estimates of the four distributional parameters over all simulation conditions was the log-probability regression method. With this method, censored observations are assumed to follow the zero-to-censoring level portion of a lognormal distribution obtained by a least squares regression between logarithms of uncensored concentration observations and their z scores. When method performance was separately evaluated for each distributional parameter over all simulation conditions, the log-probability regression method still had the smallest errors for the mean and standard deviation, but the lognormal maximum likelihood method had the smallest errors for the median and interquartile range. When data sets were classified prior to parameter estimation into groups reflecting their probable parent distributions, the ranking of estimation methods was similar, but the accuracy of error estimates was markedly improved over those without classification.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gilliom, R.J.; Helsel, D.R.
1986-02-01
A recurring difficulty encountered in investigations of many metals and organic contaminants in ambient waters is that a substantial portion of water sample concentrations are below limits of detection established by analytical laboratories. Several methods were evaluated for estimating distributional parameters for such censored data sets using only uncensored observations. Their reliabilities were evaluated by a Monte Carlo experiment in which small samples were generated from a wide range of parent distributions and censored at varying levels. Eight methods were used to estimate the mean, standard deviation, median, and interquartile range. Criteria were developed, based on the distribution of uncensoredmore » observations, for determining the best performing parameter estimation method for any particular data det. The most robust method for minimizing error in censored-sample estimates of the four distributional parameters over all simulation conditions was the log-probability regression method. With this method, censored observations are assumed to follow the zero-to-censoring level portion of a lognormal distribution obtained by a least squares regression between logarithms of uncensored concentration observations and their z scores. When method performance was separately evaluated for each distributional parameter over all simulation conditions, the log-probability regression method still had the smallest errors for the mean and standard deviation, but the lognormal maximum likelihood method had the smallest errors for the median and interquartile range. When data sets were classified prior to parameter estimation into groups reflecting their probable parent distributions, the ranking of estimation methods was similar, but the accuracy of error estimates was markedly improved over those without classification.« less
Estimation of distributional parameters for censored trace-level water-quality data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gilliom, R.J.; Helsel, D.R.
1984-01-01
A recurring difficulty encountered in investigations of many metals and organic contaminants in ambient waters is that a substantial portion of water-sample concentrations are below limits of detection established by analytical laboratories. Several methods were evaluated for estimating distributional parameters for such censored data sets using only uncensored observations. Their reliabilities were evaluated by a Monte Carlo experiment in which small samples were generated from a wide range of parent distributions and censored at varying levels. Eight methods were used to estimate the mean, standard deviation, median, and interquartile range. Criteria were developed, based on the distribution of uncensored observations,more » for determining the best-performing parameter estimation method for any particular data set. The most robust method for minimizing error in censored-sample estimates of the four distributional parameters over all simulation conditions was the log-probability regression method. With this method, censored observations are assumed to follow the zero-to-censoring level portion of a lognormal distribution obtained by a least-squares regression between logarithms of uncensored concentration observations and their z scores. When method performance was separately evaluated for each distributional parameter over all simulation conditions, the log-probability regression method still had the smallest errors for the mean and standard deviation, but the lognormal maximum likelihood method had the smallest errors for the median and interquartile range. When data sets were classified prior to parameter estimation into groups reflecting their probable parent distributions, the ranking of estimation methods was similar, but the accuracy of error estimates was markedly improved over those without classification. 6 figs., 6 tabs.« less
Effects of insertion speed and trocar stiffness on the accuracy of needle position for brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGill, Carl S.; Schwartz, Jonathon A.; Moore, Jason Z.
2012-04-15
Purpose: In prostate brachytherapy, accurate positioning of the needle tip to place radioactive seeds at its target site is critical for successful radiation treatment. During the procedure, needle deflection leads to seed misplacement and suboptimal radiation dose to cancerous cells. In practice, radiation oncologists commonly use high-speed hand needle insertion to minimize displacement of the prostate as well as the needle deflection. Effects of speed during needle insertion and stiffness of trocar (a solid rod inside the hollow cannula) on needle deflection are studied. Methods: Needle insertion experiments into phantom were performed using a 2{sup 2} factorial design (2 parametersmore » at 2 levels), with each condition having replicates. Analysis of the deflection data included calculating the average, standard deviation, and analysis of variance (ANOVA) to find significant single and two-way interaction factors. Results: The stiffer tungsten carbide trocar is effective in reducing the average and standard deviation of needle deflection. The fast insertion speed together with the stiffer trocar generated the smallest average and standard deviation for needle deflection for almost all cases. Conclusions: The combination of stiff tungsten carbide trocar and fast needle insertion speed are important to decreasing needle deflection. The knowledge gained from this study can be used to improve the accuracy of needle insertion during brachytherapy procedures.« less
Entanglement transitions induced by large deviations
NASA Astrophysics Data System (ADS)
Bhosale, Udaysinh T.
2017-12-01
The probability of large deviations of the smallest Schmidt eigenvalue for random pure states of bipartite systems, denoted as A and B , is computed analytically using a Coulomb gas method. It is shown that this probability, for large N , goes as exp[-β N2Φ (ζ ) ] , where the parameter β is the Dyson index of the ensemble, ζ is the large deviation parameter, while the rate function Φ (ζ ) is calculated exactly. Corresponding equilibrium Coulomb charge density is derived for its large deviations. Effects of the large deviations of the extreme (largest and smallest) Schmidt eigenvalues on the bipartite entanglement are studied using the von Neumann entropy. Effect of these deviations is also studied on the entanglement between subsystems 1 and 2, obtained by further partitioning the subsystem A , using the properties of the density matrix's partial transpose ρ12Γ. The density of states of ρ12Γ is found to be close to the Wigner's semicircle law with these large deviations. The entanglement properties are captured very well by a simple random matrix model for the partial transpose. The model predicts the entanglement transition across a critical large deviation parameter ζ . Log negativity is used to quantify the entanglement between subsystems 1 and 2. Analytical formulas for it are derived using the simple model. Numerical simulations are in excellent agreement with the analytical results.
Entanglement transitions induced by large deviations.
Bhosale, Udaysinh T
2017-12-01
The probability of large deviations of the smallest Schmidt eigenvalue for random pure states of bipartite systems, denoted as A and B, is computed analytically using a Coulomb gas method. It is shown that this probability, for large N, goes as exp[-βN^{2}Φ(ζ)], where the parameter β is the Dyson index of the ensemble, ζ is the large deviation parameter, while the rate function Φ(ζ) is calculated exactly. Corresponding equilibrium Coulomb charge density is derived for its large deviations. Effects of the large deviations of the extreme (largest and smallest) Schmidt eigenvalues on the bipartite entanglement are studied using the von Neumann entropy. Effect of these deviations is also studied on the entanglement between subsystems 1 and 2, obtained by further partitioning the subsystem A, using the properties of the density matrix's partial transpose ρ_{12}^{Γ}. The density of states of ρ_{12}^{Γ} is found to be close to the Wigner's semicircle law with these large deviations. The entanglement properties are captured very well by a simple random matrix model for the partial transpose. The model predicts the entanglement transition across a critical large deviation parameter ζ. Log negativity is used to quantify the entanglement between subsystems 1 and 2. Analytical formulas for it are derived using the simple model. Numerical simulations are in excellent agreement with the analytical results.
Climate change and the detection of trends in annual runoff
McCabe, G.J.; Wolock, D.M.
1997-01-01
This study examines the statistical likelihood of detecting a trend in annual runoff given an assumed change in mean annual runoff, the underlying year-to-year variability in runoff, and serial correlation of annual runoff. Means, standard deviations, and lag-1 serial correlations of annual runoff were computed for 585 stream gages in the conterminous United States, and these statistics were used to compute the probability of detecting a prescribed trend in annual runoff. Assuming a linear 20% change in mean annual runoff over a 100 yr period and a significance level of 95%, the average probability of detecting a significant trend was 28% among the 585 stream gages. The largest probability of detecting a trend was in the northwestern U.S., the Great Lakes region, the northeastern U.S., the Appalachian Mountains, and parts of the northern Rocky Mountains. The smallest probability of trend detection was in the central and southwestern U.S., and in Florida. Low probabilities of trend detection were associated with low ratios of mean annual runoff to the standard deviation of annual runoff and with high lag-1 serial correlation in the data.
NASA Astrophysics Data System (ADS)
Wei, Xiangyang; Peng, Yanke; Jing, Gaoshan; Cui, Tianhong
2018-05-01
The thickness of perovskite absorber layer is a critical parameter to determine a planar structured perovskite solar cell’s performance. By modifying the spin coating speed and PbI2/N,N-dimethylformamide (DMF) solution concentration, the thickness of perovskite absorber layer was optimized to obtain high-performance solar cells. Using a PbI2/DMF solution of 1.3 mol/L, maximum power conversion efficiency (PCE) of a perovskite solar cell is 15.5% with a perovskite film of 413 nm at 5000 rpm, and PCE of 14.3% was also obtained for a solar cell with a perovskite film of 182 nm thick. It is derived that higher concentration of PbI2/DMF will result in better perovskite solar cells. Additionally, these perovskite solar cells are highly uniform. In 14 sets of solar cells, standard deviations of 11 sets of solar cells were less than 0.50% and the smallest standard deviation was 0.25%, which demonstrates the reliability and effectiveness of hybrid physical chemical vapor deposition (HPCVD) method.
The gait standard deviation, a single measure of kinematic variability.
Sangeux, Morgan; Passmore, Elyse; Graham, H Kerr; Tirosh, Oren
2016-05-01
Measurement of gait kinematic variability provides relevant clinical information in certain conditions affecting the neuromotor control of movement. In this article, we present a measure of overall gait kinematic variability, GaitSD, based on combination of waveforms' standard deviation. The waveform standard deviation is the common numerator in established indices of variability such as Kadaba's coefficient of multiple correlation or Winter's waveform coefficient of variation. Gait data were collected on typically developing children aged 6-17 years. Large number of strides was captured for each child, average 45 (SD: 11) for kinematics and 19 (SD: 5) for kinetics. We used a bootstrap procedure to determine the precision of GaitSD as a function of the number of strides processed. We compared the within-subject, stride-to-stride, variability with the, between-subject, variability of the normative pattern. Finally, we investigated the correlation between age and gait kinematic, kinetic and spatio-temporal variability. In typically developing children, the relative precision of GaitSD was 10% as soon as 6 strides were captured. As a comparison, spatio-temporal parameters required 30 strides to reach the same relative precision. The ratio stride-to-stride divided by normative pattern variability was smaller in kinematic variables (the smallest for pelvic tilt, 28%) than in kinetic and spatio-temporal variables (the largest for normalised stride length, 95%). GaitSD had a strong, negative correlation with age. We show that gait consistency may stabilise only at, or after, skeletal maturity. Copyright © 2016 Elsevier B.V. All rights reserved.
Fouad, Heba M; Abdelhakim, Mohamad A; Awadein, Ahmed; Elhilali, Hala
2016-10-01
To compare the outcomes of medial rectus (MR) muscle pulley fixation and augmented recession in children with convergence excess esotropia and variable-angle infantile esotropia. This was a prospective randomized interventional study in which children with convergence excess esotropia or variable-angle infantile esotropia were randomly allocated to either augmented MR muscle recession (augmented group) or MR muscle pulley posterior fixation (pulley group). In convergence excess, the MR recession was based on the average of distance and near angles of deviation with distance correction in the augmented group, and on the distance angle of deviation in the pulley group. In variable-angle infantile esotropia, the MR recession was based on the average of the largest and smallest angles in the augmented group and on the smallest angle in the pulley group. Pre- and postoperative ductions, versions, pattern strabismus, smallest and largest angles of deviation, and angle disparity were analyzed. Surgery was performed on 60 patients: 30 underwent bilateral augmented MR recession, and 30 underwent bilateral MR recession with pulley fixation. The success rate was statistically significantly higher (P = 0.037) in the pulley group (70%) than in the augmented group (40%). The postoperative smallest and largest angles and the angle disparity were statistically significantly lower in the pulley group than the augmented group (P < 0.01). Medial rectus muscle pulley fixation is a useful surgical step for addressing marked variability of the angle in variable angle esotropia and convergence excess esotropia. Copyright © 2016 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.
Communication: Non-Hadwiger terms in morphological thermodynamics of fluids
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hansen-Goos, Hendrik, E-mail: hendrik.hansen-goos@uni-tuebingen.de
We demonstrate that the Hadwiger form of the free energy of a fluid in contact with a wall is insufficient to describe the low-density behavior of a hard-sphere fluid. This implies that morphological thermodynamics of the hard-sphere fluid is an approximate theory if only four geometric measures are included. In order to quantify deviations from the Hadwiger form we extend standard fundamental measure theory of the bulk fluid by introducing additional scaled-particle variables which allow for the description of non-Hadwiger coefficients. The theory is in excellent agreement with recent computer simulations. The fact that the leading non-Hadwiger coefficient is onemore » order of magnitude smaller than the smallest Hadwiger coefficient lends confidence to the numerous results that have been previously obtained within standard morphological thermodynamics.« less
NASA Astrophysics Data System (ADS)
Zou, Z.; Xiao, X.
2015-12-01
With a high temporal resolution and a large covering area, MODIS data are particularly useful in assessing vegetation destruction and recovery of a wide range of areas. In this study, MOD13Q1 data of the growing season (Mar. to Nov.) are used to calculate the Maximum NDVI (NDVImax) of each year. This study calculates each pixel's mean and standard deviation of the NDVImaxs in the 8 years before the earthquake. If the pixel's NDVImax of 2008 is two standard deviation smaller than the mean NDVImax, this pixel is detected as a vegetation destructed pixel. For each vegetation destructed pixel, its similar pixels of the same vegetation type are selected within the latitude difference of 0.5 degrees, altitude difference of 100 meters and slope difference of 3 degrees. Then the NDVImax difference of each vegetation destructed pixel and its similar pixels are calculated. The 5 similar pixels with the smallest NDVImax difference in the 8 years before the earthquake are selected as reference pixels. The mean NDVImaxs of these reference pixels after the earthquake are calculated and serve as the criterion to assess the vegetation recovery process.
PTV margin determination in conformal SRT of intracranial lesions
Parker, Brent C.; Shiu, Almon S.; Maor, Moshe H.; Lang, Frederick F.; Liu, H. Helen; White, R. Allen; Antolak, John A.
2002-01-01
The planning target volume (PTV) includes the clinical target volume (CTV) to be irradiated and a margin to account for uncertainties in the treatment process. Uncertainties in miniature multileaf collimator (mMLC) leaf positioning, CT scanner spatial localization, CT‐MRI image fusion spatial localization, and Gill‐Thomas‐Cosman (GTC) relocatable head frame repositioning were quantified for the purpose of determining a minimum PTV margin that still delivers a satisfactory CTV dose. The measured uncertainties were then incorporated into a simple Monte Carlo calculation for evaluation of various margin and fraction combinations. Satisfactory CTV dosimetric criteria were selected to be a minimum CTV dose of 95% of the PTV dose and at least 95% of the CTV receiving 100% of the PTV dose. The measured uncertainties were assumed to be Gaussian distributions. Systematic errors were added linearly and random errors were added in quadrature assuming no correlation to arrive at the total combined error. The Monte Carlo simulation written for this work examined the distribution of cumulative dose volume histograms for a large patient population using various margin and fraction combinations to determine the smallest margin required to meet the established criteria. The program examined 5 and 30 fraction treatments, since those are the only fractionation schemes currently used at our institution. The fractionation schemes were evaluated using no margin, a margin of just the systematic component of the total uncertainty, and a margin of the systematic component plus one standard deviation of the total uncertainty. It was concluded that (i) a margin of the systematic error plus one standard deviation of the total uncertainty is the smallest PTV margin necessary to achieve the established CTV dose criteria, and (ii) it is necessary to determine the uncertainties introduced by the specific equipment and procedures used at each institution since the uncertainties may vary among locations. PACS number(s): 87.53.Kn, 87.53.Ly PMID:12132939
Vasudevamurthy, G.; Byun, T. S.; Pappano, Pete; ...
2015-03-13
Here we present a comparison of the measured baseline mechanical and physical properties of with grain (WG) and against grain (AG) non-ASTM size NBG-18 graphite. The objectives of the experiments were twofold: (1) assess the variation in properties with grain orientation; (2) establish a correlation between specimen tensile strength and size. The tensile strength of the smallest sized (4 mm diameter) specimens were about 5% higher than the standard specimens (12 mm diameter) but still within one standard deviation of the ASTM specimen size indicating no significant dependence of strength on specimen size. The thermal expansion coefficient and elastic constantsmore » did not show significant dependence on specimen size. Lastly, experimental data indicated that the variation of thermal expansion coefficient and elastic constants were still within 5% between the different grain orientations, confirming the isotropic nature of NBG-18 graphite in physical properties.« less
Evaluation of different methods for determining growing degree-day thresholds in apricot cultivars
NASA Astrophysics Data System (ADS)
Ruml, Mirjana; Vuković, Ana; Milatović, Dragan
2010-07-01
The aim of this study was to examine different methods for determining growing degree-day (GDD) threshold temperatures for two phenological stages (full bloom and harvest) and select the optimal thresholds for a greater number of apricot ( Prunus armeniaca L.) cultivars grown in the Belgrade region. A 10-year data series were used to conduct the study. Several commonly used methods to determine the threshold temperatures from field observation were evaluated: (1) the least standard deviation in GDD; (2) the least standard deviation in days; (3) the least coefficient of variation in GDD; (4) regression coefficient; (5) the least standard deviation in days with a mean temperature above the threshold; (6) the least coefficient of variation in days with a mean temperature above the threshold; and (7) the smallest root mean square error between the observed and predicted number of days. In addition, two methods for calculating daily GDD, and two methods for calculating daily mean air temperatures were tested to emphasize the differences that can arise by different interpretations of basic GDD equation. The best agreement with observations was attained by method (7). The lower threshold temperature obtained by this method differed among cultivars from -5.6 to -1.7°C for full bloom, and from -0.5 to 6.6°C for harvest. However, the “Null” method (lower threshold set to 0°C) and “Fixed Value” method (lower threshold set to -2°C for full bloom and to 3°C for harvest) gave very good results. The limitations of the widely used method (1) and methods (5) and (6), which generally performed worst, are discussed in the paper.
NASA Technical Reports Server (NTRS)
Meneghini, Robert; Kim, Hyokyung
2016-01-01
For an airborne or spaceborne radar, the precipitation-induced path attenuation can be estimated from the measurements of the normalized surface cross section, sigma 0, in the presence and absence of precipitation. In one implementation, the mean rain-free estimate and its variability are found from a lookup table (LUT) derived from previously measured data. For the dual-frequency precipitation radar aboard the global precipitation measurement satellite, the nominal table consists of the statistics of the rain-free 0 over a 0.5 deg x 0.5 deg latitude-longitude grid using a three-month set of input data. However, a problem with the LUT is an insufficient number of samples in many cells. An alternative table is constructed by a stepwise procedure that begins with the statistics over a 0.25 deg x 0.25 deg grid. If the number of samples at a cell is too few, the area is expanded, cell by cell, choosing at each step that cell that minimizes the variance of the data. The question arises, however, as to whether the selected region corresponds to the smallest variance. To address this question, a second type of variable-averaging grid is constructed using all possible spatial configurations and computing the variance of the data within each region. Comparisons of the standard deviations for the fixed and variable-averaged grids are given as a function of incidence angle and surface type using a three-month set of data. The advantage of variable spatial averaging is that the average standard deviation can be reduced relative to the fixed grid while satisfying the minimum sample requirement.
Measuring Liquid-Level Utilizing Wedge Wave
Honma, Yudai; Mori, Masayuki; Ihara, Ikuo
2017-01-01
A new technique for measuring liquid-level utilizing wedge wave is presented and demonstrated through FEM simulation and a corresponding experiment. The velocities of wedge waves in the air and the water, and the sensitivities for the measurement, are compared with the simulation and the results obtained in the experiments. Combining the simulation and the measurement theory, it is verified that the foundation framework for the methods is available. The liquid-level sensing is carried out using the aluminum waveguide with a 30° wedge in the water. The liquid-level is proportional to the traveling time of the mode 1 wedge wave. The standard deviations and the uncertainties of the measurement are 0.65 mm and 0.21 mm using interface echo, and 0.39 mm and 0.12 mm utilized by end echo, which are smaller than the industry standard of 1.5 mm. The measurement resolutions are 7.68 μm using the interface echo, which is the smallest among all the guided acoustic wave-based liquid-level sensing. PMID:29267232
Lee, Sang Hun; Yoo, Myung Hoon; Park, Jun Woo; Kang, Byung Chul; Yang, Chan Joo; Kang, Woo Suk; Ahn, Joong Ho; Chung, Jong Woo; Park, Hong Ju
2018-06-01
To evaluate whether video head impulse test (vHIT) gains are dependent on the measuring device and method of analysis. Prospective study. vHIT was performed in 25 healthy subjects using two devices simultaneously. vHIT gains were compared between these instruments and using five different methods of comparing position and velocity gains during head movement intervals. The two devices produced different vHIT gain results with the same method of analysis. There were also significant differences in the vHIT gains measured using different analytical methods. The gain analytic method that compares the areas under the velocity curve (AUC) of the head and eye movements during head movements showed lower vHIT gains than a method that compared the peak velocities of the head and eye movements. The former method produced the vHIT gain with the smallest standard deviation among the five procedures tested in this study. vHIT gains differ in normal subjects depending on the device and method of analysis used, suggesting that it is advisable for each device to have its own normal values. Gain calculations that compare the AUC of the head and eye movements during the head movements show the smallest variance.
Smith, Brian T; Coiro, Daniel J; Finson, Richard; Betz, Randal R; McCarthy, James
2002-03-01
Force-sensing resistors (FSRs) were used to detect the transitions between five main phases of gait for the control of electrical stimulation (ES) while walking with seven children with spastic diplegia, cerebral palsy. The FSR positions within each child's insoles were customized based on plantar pressure profiles determined using a pressure-sensitive membrane array (Tekscan Inc., Boston, MA). The FSRs were placed in the insoles so that pressure transitions coincided with an ipsilateral or contralateral gait event. The transitions between the following gait phases were determined: loading response, mid- and terminal stance, and pre- and initial swing. Following several months of walking on a regular basis with FSR-triggered intramuscular ES to the hip and knee extensors, hip abductors, and ankle dorsi and plantar flexors, the accuracy and reliability of the FSRs to detect gait phase transitions were evaluated. Accuracy was evaluated with four of the subjects by synchronizing the output of the FSR detection scheme with a VICON (Oxford Metrics, U.K.) motion analysis system, which was used as the gait event reference. While mean differences between each FSR-detected gait event and that of the standard (VICON) ranged from +35 ms (indicating that the FSR detection scheme recognized the event before it actually happened) to -55 ms (indicating that the FSR scheme recognized the event after it occurred), the difference data was widely distributed, which appeared to be due in part to both intrasubject (step-to-step) and intersubject variability. Terminal stance exhibited the largest mean difference and standard deviation, while initial swing exhibited the smallest deviation and preswing the smallest mean difference. To determine step-to-step reliability, all seven children walked on a level walkway for at least 50 steps. Of 642 steps, there were no detection errors in 94.5% of the steps. Of the steps that contained a detection error, 80% were due to the failure of the FSR signal to reach the programmed threshold level during the transition to loading response. Recovery from an error always occurred one to three steps later.
Inter-laboratory Comparison of Three Earplug Fit-test Systems
Byrne, David C.; Murphy, William J.; Krieg, Edward F.; Ghent, Robert M.; Michael, Kevin L.; Stefanson, Earl W.; Ahroon, William A.
2017-01-01
The National Institute for Occupational Safety and Health (NIOSH) sponsored tests of three earplug fit-test systems (NIOSH HPD Well-Fit™, Michael & Associates FitCheck, and Honeywell Safety Products VeriPRO®). Each system was compared to laboratory-based real-ear attenuation at threshold (REAT) measurements in a sound field according to ANSI/ASA S12.6-2008 at the NIOSH, Honeywell Safety Products, and Michael & Associates testing laboratories. An identical study was conducted independently at the U.S. Army Aeromedical Research Laboratory (USAARL), which provided their data for inclusion in this report. The Howard Leight Airsoft premolded earplug was tested with twenty subjects at each of the four participating laboratories. The occluded fit of the earplug was maintained during testing with a soundfield-based laboratory REAT system as well as all three headphone-based fit-test systems. The Michael & Associates lab had highest average A-weighted attenuations and smallest standard deviations. The NIOSH lab had the lowest average attenuations and the largest standard deviations. Differences in octave-band attenuations between each fit-test system and the American National Standards Institute (ANSI) sound field method were calculated (Attenfit-test - AttenANSI). A-weighted attenuations measured with FitCheck and HPD Well-Fit systems demonstrated approximately ±2 dB agreement with the ANSI sound field method, but A-weighted attenuations measured with the VeriPRO system underestimated the ANSI laboratory attenuations. For each of the fit-test systems, the average A-weighted attenuation across the four laboratories was not significantly greater than the average of the ANSI sound field method. Standard deviations for residual attenuation differences were about ±2 dB for FitCheck and HPD Well-Fit compared to ±4 dB for VeriPRO. Individual labs exhibited a range of agreement from less than a dB to as much as 9.4 dB difference with ANSI and REAT estimates. Factors such as the experience of study participants and test administrators, and the fit-test psychometric tasks are suggested as possible contributors to the observed results. PMID:27786602
Comparison of the Characteristics and Performance of Flurbiprofen 8.75 mg Spray for Sore Throat.
Veale, David; Shephard, Adrian; Adams, Verity; Lidster, Charlotte
2017-01-01
Sore throat sprays provide targeted relief by delivering the active ingredient directly to the site of pain. Different sprays vary in characteristics, thus affecting delivery of the active ingredient to the throat, which can impact compliance. The characteristics and performance of FLURBIPROFEN 8.75 mg SPRAY were compared with 12 other sprays. Parameters assessed included spray angle and pattern, droplet size distribution, shot weight uniformity and shot weight throughout life. Among all sprays tested WICK Sulagil Halsspray had the smallest spray angle (46°) and also the smallest diameter spray pattern (X=32.8 mm; Y=34.4 mm). Thiovalone® Buccal Spray Suspension had both the largest spray angle (82°) and largest diameter spray pattern (X=62.6 mm; Y=78.0 mm). Hasco Sept® Aerosol Spray had the smallest droplet size (Dv90=118.4 μm) whereas OKi infiammazione e dolore® 0.16% spray had the largest (Dv90=214.34 μm). In terms of shot weight uniformity, TANTUM® VERDE GOLA 0.25% spray showed the least variation (2% RSD) between shots and UNIBEN Aerosol Spray the most (23.4% RSD). Shot weight throughout life studies showed that FLURBIPROFEN 8.75 mg SPRAY had the least deviation from shot weight (1.77%) whereas OKi infiammazione e dolore® 0.16% spray deviated the most (44.9%). FLURBIPROFEN 8.75 mg SPRAY had the second smallest spray angle/pattern and droplet size distribution and also the least variation in shot weight. Different sore throat sprays vary in different attributes, affecting delivery of the active ingredient. FLURBIPROFEN 8.75 mg SPRAY performed well overall, ranking first among all sprays tested, and providing a dose which is targeted and uniformly delivered throughout the life of the bottle. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Testing the Quantum-Classical Boundary and Dimensionality of Quantum Systems
NASA Astrophysics Data System (ADS)
Shun, Poh Hou
Quantum theory introduces a cut between the observer and the observed system [1], but does not provide a definition of what is an observer [2]. Based on an informational def- inition of the observer, Grinbaum has recently [3] predicted an upper bound on bipartite correlations in the Clauser-Horne-Shimony-Holt (CHSH) Bell scenario equal to 2.82537, which is slightly smaller than the Tsirelson bound [4] of standard quantum theory, but is consistent with all the available experimental results [5--17]. Not being able to exceed Grin- baum's limit would support that quantum theory is only an effective description of a more fundamental theory and would have a deep impact in physics and quantum information processing. In this thesis, we present a test of the CHSH inequality on photon pairs in maximally entangled states of polarization in which a value 2.8276 +/- 0.00082 is observed, violating Grinbaum's bound by 2.72 standard deviations and providing the smallest distance with respect to Tsirelson's bound ever reported, namely, 0.0008 +/- 0.00082. (Abstract shortened by UMI.).
Couch height–based patient setup for abdominal radiation therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ohira, Shingo; Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita; Ueda, Yoshihiro
2016-04-01
There are 2 methods commonly used for patient positioning in the anterior-posterior (A-P) direction: one is the skin mark patient setup method (SMPS) and the other is the couch height–based patient setup method (CHPS). This study compared the setup accuracy of these 2 methods for abdominal radiation therapy. The enrollment for this study comprised 23 patients with pancreatic cancer. For treatments (539 sessions), patients were set up by using isocenter skin marks and thereafter treatment couch was shifted so that the distance between the isocenter and the upper side of the treatment couch was equal to that indicated on themore » computed tomographic (CT) image. Setup deviation in the A-P direction for CHPS was measured by matching the spine of the digitally reconstructed radiograph (DRR) of a lateral beam at simulation with that of the corresponding time-integrated electronic portal image. For SMPS with no correction (SMPS/NC), setup deviation was calculated based on the couch-level difference between SMPS and CHPS. SMPS/NC was corrected using 2 off-line correction protocols: no action level (SMPS/NAL) and extended NAL (SMPS/eNAL) protocols. Margins to compensate for deviations were calculated using the Stroom formula. A-P deviation > 5 mm was observed in 17% of SMPS/NC, 4% of SMPS/NAL, and 4% of SMPS/eNAL sessions but only in one CHPS session. For SMPS/NC, 7 patients (30%) showed deviations at an increasing rate of > 0.1 mm/fraction, but for CHPS, no such trend was observed. The standard deviations (SDs) of systematic error (Σ) were 2.6, 1.4, 0.6, and 0.8 mm and the root mean squares of random error (σ) were 2.1, 2.6, 2.7, and 0.9 mm for SMPS/NC, SMPS/NAL, SMPS/eNAL, and CHPS, respectively. Margins to compensate for the deviations were wide for SMPS/NC (6.7 mm), smaller for SMPS/NAL (4.6 mm) and SMPS/eNAL (3.1 mm), and smallest for CHPS (2.2 mm). Achieving better setup with smaller margins, CHPS appears to be a reproducible method for abdominal patient setup.« less
Braun, T; Dochtermann, S; Krause, E; Schmidt, M; Schorn, K; Hempel, J M
2011-09-01
The present study analyzes the best combination of frequencies for the calculation of mean hearing loss in pure tone threshold audiometry for correlation with hearing loss for numbers in speech audiometry, since the literature describes different calculation variations for plausibility checking in expertise. Three calculation variations, A (250, 500 and 1000 Hz), B (500 and 1000 Hz) and C (500, 1000 and 2000 Hz), were compared. Audiograms in 80 patients with normal hearing, 106 patients with hearing loss and 135 expertise patients were analyzed in a retrospective manner. Differences between mean pure tone audiometry thresholds and hearing loss for numbers were calculated and statistically compared separately for the right and the left ear in the three patient collectives. We found the calculation variation A to be the best combination of frequencies, since it yielded the smallest standard deviations while being statistically different to calculation variations B and C. The 1- and 2.58-fold standard deviation (representing 68.3% and 99.0% of all values) was ±4.6 and ±11.8 dB for calculation variation A in patients with hearing loss, respectively. For plausibility checking in expertise, the mean threshold from the frequencies 250, 500 and 1000 Hz should be compared to the hearing loss for numbers. The common recommendation reported by the literature to doubt plausibility when the difference of these values exceeds ±5 dB is too strict as shown by this study.
Do human parents face a quantity-quality tradeoff?: evidence from a Shuar community.
Hagen, Edward H; Barrett, H Clark; Price, Michael E
2006-07-01
A number of evolutionary theories of human life history assume a quantity-quality tradeoff for offspring production: parents with fewer offspring can have higher biological fitness than those with more. Direct evidence for such a tradeoff, however, is mixed. We tested this assumption in a community of Ecuadorian Shuar hunter-horticulturalists, using child anthropometry as a proxy for fitness. We measured the impact of household consumer/producer (CP) ratio on height, weight, skinfold thicknesses, and arm and calf circumferences of 85 children and young adults. To control for possible "phenotypic" correlates that might mask the effect of CP ratio on anthropometry, we also measured household garden productivity, wealth, and social status. Regression models of the age-standardized variables indicated a significant negative impact of CP ratio on child growth and nutrition. The age-standardized height and weight of children in households with the largest CP ratio (10) were 1.38 and 1.44 standard deviations, respectively, below those of children in households with the smallest CP ratio (2). Surprisingly, garden productivity, wealth, and status had little to no effect on the fitness proxies. There was, however, an interesting and unexpected interaction between status and sex: for females, but not males, higher father status correlated significantly with higher values on the proxies.
Water exchange through the Kerama Gap estimated with a 25-year Pacific HYbrid Coordinate Ocean Model
NASA Astrophysics Data System (ADS)
Zhou, Wenzheng; Yu, Fei; Nan, Feng
2017-11-01
Variations in water exchange through the Kerama Gap (between Okinawa Island and Miyakojima Island) from 1979 to 2003 were estimated with the 0.08° Pacific HYbrid Coordinate Ocean Model (HYCOM). The model results show that the mean transport through the Kerama Gap (KGT) from the Pacific Ocean to the East China Sea (ECS) was 2.1 Sv, which agrees well with the observed mean KGT (2.0 Sv) for 2009-2010. Over the time period examined, the monthly KGT varied from -10.9 Sv to 15.8 Sv and had a standard deviation of ± 5.0 Sv. The water mainly enters the ECS via the subsurface layer (300-500 m) along the northeastern slope of the Kerama Gap and mainly flows out of the ECS into the southwest of the Kerama Gap. The seasonal and interannual variations of the KGT and the Kuroshio upstream transport were negatively correlated. The Kuroshio upstream transport was largest in summer and smallest in autumn while the KGT was smallest in summer (1.02 Sv) and largest in spring (2.94 Sv) and autumn (2.44 Sv). The seasonal and interannual variations in the Kuroshio downstream (across the PN-line) transport differed significantly from the Kuroshio upstream transport but corresponded well with the KGT and the sum of the transport through the Kerama Gap and the Kuroshio upstream, which indicates that information about variation in the KGT is important for determining variation in the Kuroshio transport along the PN-line.
Resistance Training Increases the Variability of Strength Test Scores
2009-06-08
standard deviations for pretest and posttest strength measurements. This information was recorded for every strength test used in a total of 377 samples...significant if the posttest standard deviation consistently was larger than the pretest standard deviation. This condition could be satisfied even if...the difference in the standard deviations was small. For example, the posttest standard deviation might be 1% larger than the pretest standard
Quan, Hui; Zhang, Ji
2003-09-15
Analyses of study variables are frequently based on log transformations. To calculate the power for detecting the between-treatment difference in the log scale, we need an estimate of the standard deviation of the log-transformed variable. However, in many situations a literature search only provides the arithmetic means and the corresponding standard deviations. Without individual log-transformed data to directly calculate the sample standard deviation, we need alternative methods to estimate it. This paper presents methods for estimating and constructing confidence intervals for the standard deviation of a log-transformed variable given the mean and standard deviation of the untransformed variable. It also presents methods for estimating the standard deviation of change from baseline in the log scale given the means and standard deviations of the untransformed baseline value, on-treatment value and change from baseline. Simulations and examples are provided to assess the performance of these estimates. Copyright 2003 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Pickard, William F.
2004-10-01
The classical PERT inverse statistics problem requires estimation of the mean, \\skew1\\bar{m} , and standard deviation, s, of a unimodal distribution given estimates of its mode, m, and of the smallest, a, and largest, b, values likely to be encountered. After placing the problem in historical perspective and showing that it is ill-posed because it is underdetermined, this paper offers an approach to resolve the ill-posedness: (a) by interpreting a and b modes of order statistic distributions; (b) by requiring also an estimate of the number of samples, N, considered in estimating the set {m, a, b}; and (c) by maximizing a suitable likelihood, having made the traditional assumption that the underlying distribution is beta. Exact formulae relating the four parameters of the beta distribution to {m, a, b, N} and the assumed likelihood function are then used to compute the four underlying parameters of the beta distribution; and from them, \\skew1\\bar{m} and s are computed using exact formulae.
7 CFR 400.204 - Notification of deviation from standards.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 6 2010-01-01 2010-01-01 false Notification of deviation from standards. 400.204... Contract-Standards for Approval § 400.204 Notification of deviation from standards. A Contractor shall advise the Corporation immediately if the Contractor deviates from the requirements of these standards...
The Standard Deviation of Launch Vehicle Environments
NASA Technical Reports Server (NTRS)
Yunis, Isam
2005-01-01
Statistical analysis is used in the development of the launch vehicle environments of acoustics, vibrations, and shock. The standard deviation of these environments is critical to accurate statistical extrema. However, often very little data exists to define the standard deviation and it is better to use a typical standard deviation than one derived from a few measurements. This paper uses Space Shuttle and expendable launch vehicle flight data to define a typical standard deviation for acoustics and vibrations. The results suggest that 3dB is a conservative and reasonable standard deviation for the source environment and the payload environment.
Minimal nuclear energy density functional
NASA Astrophysics Data System (ADS)
Bulgac, Aurel; Forbes, Michael McNeil; Jin, Shi; Perez, Rodrigo Navarro; Schunck, Nicolas
2018-04-01
We present a minimal nuclear energy density functional (NEDF) called "SeaLL1" that has the smallest number of possible phenomenological parameters to date. SeaLL1 is defined by seven significant phenomenological parameters, each related to a specific nuclear property. It describes the nuclear masses of even-even nuclei with a mean energy error of 0.97 MeV and a standard deviation of 1.46 MeV , two-neutron and two-proton separation energies with rms errors of 0.69 MeV and 0.59 MeV respectively, and the charge radii of 345 even-even nuclei with a mean error ɛr=0.022 fm and a standard deviation σr=0.025 fm . SeaLL1 incorporates constraints on the equation of state (EoS) of pure neutron matter from quantum Monte Carlo calculations with chiral effective field theory two-body (NN ) interactions at the next-to-next-to-next-to leading order (N3LO) level and three-body (NNN ) interactions at the next-to-next-to leading order (N2LO) level. Two of the seven parameters are related to the saturation density and the energy per particle of the homogeneous symmetric nuclear matter, one is related to the nuclear surface tension, two are related to the symmetry energy and its density dependence, one is related to the strength of the spin-orbit interaction, and one is the coupling constant of the pairing interaction. We identify additional phenomenological parameters that have little effect on ground-state properties but can be used to fine-tune features such as the Thomas-Reiche-Kuhn sum rule, the excitation energy of the giant dipole and Gamow-Teller resonances, the static dipole electric polarizability, and the neutron skin thickness.
Minimal nuclear energy density functional
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bulgac, Aurel; Forbes, Michael McNeil; Jin, Shi
Inmore » this paper, we present a minimal nuclear energy density functional (NEDF) called “SeaLL1” that has the smallest number of possible phenomenological parameters to date. SeaLL1 is defined by seven significant phenomenological parameters, each related to a specific nuclear property. It describes the nuclear masses of even-even nuclei with a mean energy error of 0.97 MeV and a standard deviation of 1.46 MeV , two-neutron and two-proton separation energies with rms errors of 0.69 MeV and 0.59 MeV respectively, and the charge radii of 345 even-even nuclei with a mean error ε r = 0.022 fm and a standard deviation σ r = 0.025 fm . SeaLL1 incorporates constraints on the equation of state (EoS) of pure neutron matter from quantum Monte Carlo calculations with chiral effective field theory two-body ( NN ) interactions at the next-to-next-to-next-to leading order (N3LO) level and three-body ( NNN ) interactions at the next-to-next-to leading order (N2LO) level. Two of the seven parameters are related to the saturation density and the energy per particle of the homogeneous symmetric nuclear matter, one is related to the nuclear surface tension, two are related to the symmetry energy and its density dependence, one is related to the strength of the spin-orbit interaction, and one is the coupling constant of the pairing interaction. Finally, we identify additional phenomenological parameters that have little effect on ground-state properties but can be used to fine-tune features such as the Thomas-Reiche-Kuhn sum rule, the excitation energy of the giant dipole and Gamow-Teller resonances, the static dipole electric polarizability, and the neutron skin thickness.« less
Minimal nuclear energy density functional
Bulgac, Aurel; Forbes, Michael McNeil; Jin, Shi; ...
2018-04-17
Inmore » this paper, we present a minimal nuclear energy density functional (NEDF) called “SeaLL1” that has the smallest number of possible phenomenological parameters to date. SeaLL1 is defined by seven significant phenomenological parameters, each related to a specific nuclear property. It describes the nuclear masses of even-even nuclei with a mean energy error of 0.97 MeV and a standard deviation of 1.46 MeV , two-neutron and two-proton separation energies with rms errors of 0.69 MeV and 0.59 MeV respectively, and the charge radii of 345 even-even nuclei with a mean error ε r = 0.022 fm and a standard deviation σ r = 0.025 fm . SeaLL1 incorporates constraints on the equation of state (EoS) of pure neutron matter from quantum Monte Carlo calculations with chiral effective field theory two-body ( NN ) interactions at the next-to-next-to-next-to leading order (N3LO) level and three-body ( NNN ) interactions at the next-to-next-to leading order (N2LO) level. Two of the seven parameters are related to the saturation density and the energy per particle of the homogeneous symmetric nuclear matter, one is related to the nuclear surface tension, two are related to the symmetry energy and its density dependence, one is related to the strength of the spin-orbit interaction, and one is the coupling constant of the pairing interaction. Finally, we identify additional phenomenological parameters that have little effect on ground-state properties but can be used to fine-tune features such as the Thomas-Reiche-Kuhn sum rule, the excitation energy of the giant dipole and Gamow-Teller resonances, the static dipole electric polarizability, and the neutron skin thickness.« less
7 CFR 400.174 - Notification of deviation from financial standards.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 6 2010-01-01 2010-01-01 false Notification of deviation from financial standards... Agreement-Standards for Approval; Regulations for the 1997 and Subsequent Reinsurance Years § 400.174 Notification of deviation from financial standards. An insurer must immediately advise FCIC if it deviates from...
Degrees of Freedom for Allan Deviation Estimates of Multiple Clocks
2016-04-01
Allan deviation . Allan deviation will be represented by σ and standard deviation will be represented by δ. In practice, when the Allan deviation of a...the Allan deviation of standard noise types. Once the number of degrees of freedom is known, an approximate confidence interval can be assigned by...measurement errors from paired difference data. We extend this approach by using the Allan deviation to estimate the error in a frequency standard
Industry ties in otolaryngology: initial insights from the physician payment sunshine act.
Rathi, Vinay K; Samuel, Andre M; Mehra, Saral
2015-06-01
To characterize nonresearch payments made by industry to otolaryngologists in order to explore how the potential for conflicts of interests varies among otolaryngologists and compares between otolaryngologists and other surgical specialists. Retrospective cross-sectional database analysis. Open Payments program database recently released by Centers for Medicare and Medicaid Services. Surgeons nationwide who were identified as receiving nonresearch payment from industry in accordance with the Physician Payment Sunshine Act. The proportion of otolaryngologists receiving payment, the mean payment per otolaryngologist, and the standard deviation thereof were determined using the Open Payments database and compared to other surgical specialties. Otolaryngologists were further compared by specialization, census region, sponsor, and payment amount. Less than half of otolaryngologists (48.1%) were reported as receiving payments over the study period, the second smallest proportion among surgical specialties. Otolaryngologists received the lowest mean payment per compensated individual ($573) compared to other surgical specialties. Although otolaryngology had the smallest variance in payment among surgical specialties (SD, $2806), the distribution was skewed by top earners; the top 10% of earners accounted for 87% ($2,199,254) of all payment to otolaryngologists. Otolaryngologists in the West census region were less likely to receive payments (38.6%, P < .001). Over the study period, otolaryngologists appeared to have more limited financial ties with industry compared to other surgeons, though variation exists within otolaryngology. Further refinement of the Open Payments database is needed to explore differences between otolaryngologists and leverage payment information as a tool for self-regulation. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.
Code of Federal Regulations, 2014 CFR
2014-01-01
..., CERTIFICATION, AND STANDARDS) United States Standards for Grades of Apples for Processing Size § 51.344 Size. (a... buyer and seller. (c) Size is the dimension of the apples determined by the smallest opening through...
Code of Federal Regulations, 2013 CFR
2013-01-01
..., CERTIFICATION, AND STANDARDS) United States Standards for Grades of Apples for Processing Size § 51.344 Size. (a... buyer and seller. (c) Size is the dimension of the apples determined by the smallest opening through...
Code of Federal Regulations, 2010 CFR
2010-01-01
... Standards for Grades of Apples for Processing Size § 51.344 Size. (a) The minimum and maximum sizes or range... the apples determined by the smallest opening through which it will pass. Application of Standards ...
Code of Federal Regulations, 2011 CFR
2011-01-01
... Standards for Grades of Apples for Processing Size § 51.344 Size. (a) The minimum and maximum sizes or range... the apples determined by the smallest opening through which it will pass. Application of Standards ...
Code of Federal Regulations, 2012 CFR
2012-01-01
... Standards for Grades of Apples for Processing Size § 51.344 Size. (a) The minimum and maximum sizes or range... the apples determined by the smallest opening through which it will pass. Application of Standards ...
1 CFR 21.14 - Deviations from standard organization of the Code of Federal Regulations.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 1 General Provisions 1 2010-01-01 2010-01-01 false Deviations from standard organization of the... CODIFICATION General Numbering § 21.14 Deviations from standard organization of the Code of Federal Regulations. (a) Any deviation from standard Code of Federal Regulations designations must be approved in advance...
Upgraded FAA Airfield Capacity Model. Volume 1. Supplemental User’s Guide
1981-02-01
SIGMAR (P4.0) cc 1-4 -standard deviation, in seconds, of arrival runway occupancy time (R.O.T.). SIGMAA (F4.0) cc 5-8 -standard deviation, in seconds...iI SI GMAC - The standard deviation of the time from departure clearance to start of roll. SIGMAR - The standard deviation of the arrival runway
A Visual Model for the Variance and Standard Deviation
ERIC Educational Resources Information Center
Orris, J. B.
2011-01-01
This paper shows how the variance and standard deviation can be represented graphically by looking at each squared deviation as a graphical object--in particular, as a square. A series of displays show how the standard deviation is the size of the average square.
Martin, Jeffrey D.
2002-01-01
Correlation analysis indicates that for most pesticides and concentrations, pooled estimates of relative standard deviation rather than pooled estimates of standard deviation should be used to estimate variability because pooled estimates of relative standard deviation are less affected by heteroscedasticity. The 2 Variability of Pesticide Detections and Concentrations in Field Replicate Water Samples, 1992–97 median pooled relative standard deviation was calculated for all pesticides to summarize the typical variability for pesticide data collected for the NAWQA Program. The median pooled relative standard deviation was 15 percent at concentrations less than 0.01 micrograms per liter (µg/L), 13 percent at concentrations near 0.01 µg/L, 12 percent at concentrations near 0.1 µg/L, 7.9 percent at concentrations near 1 µg/L, and 2.7 percent at concentrations greater than 5 µg/L. Pooled estimates of standard deviation or relative standard deviation presented in this report are larger than estimates based on averages, medians, smooths, or regression of the individual measurements of standard deviation or relative standard deviation from field replicates. Pooled estimates, however, are the preferred method for characterizing variability because they provide unbiased estimates of the variability of the population. Assessments of variability based on standard deviation (rather than variance) underestimate the true variability of the population. Because pooled estimates of variability are larger than estimates based on other approaches, users of estimates of variability must be cognizant of the approach used to obtain the estimate and must use caution in the comparison of estimates based on different approaches.
Basic life support: evaluation of learning using simulation and immediate feedback devices1.
Tobase, Lucia; Peres, Heloisa Helena Ciqueto; Tomazini, Edenir Aparecida Sartorelli; Teodoro, Simone Valentim; Ramos, Meire Bruna; Polastri, Thatiane Facholi
2017-10-30
to evaluate students' learning in an online course on basic life support with immediate feedback devices, during a simulation of care during cardiorespiratory arrest. a quasi-experimental study, using a before-and-after design. An online course on basic life support was developed and administered to participants, as an educational intervention. Theoretical learning was evaluated by means of a pre- and post-test and, to verify the practice, simulation with immediate feedback devices was used. there were 62 participants, 87% female, 90% in the first and second year of college, with a mean age of 21.47 (standard deviation 2.39). With a 95% confidence level, the mean scores in the pre-test were 6.4 (standard deviation 1.61), and 9.3 in the post-test (standard deviation 0.82, p <0.001); in practice, 9.1 (standard deviation 0.95) with performance equivalent to basic cardiopulmonary resuscitation, according to the feedback device; 43.7 (standard deviation 26.86) mean duration of the compression cycle by second of 20.5 (standard deviation 9.47); number of compressions 167.2 (standard deviation 57.06); depth of compressions of 48.1 millimeter (standard deviation 10.49); volume of ventilation 742.7 (standard deviation 301.12); flow fraction percentage of 40.3 (standard deviation 10.03). the online course contributed to learning of basic life support. In view of the need for technological innovations in teaching and systematization of cardiopulmonary resuscitation, simulation and feedback devices are resources that favor learning and performance awareness in performing the maneuvers.
Comparison Of Methods Used In Cartography For The Skeletonisation Of Areal Objects
NASA Astrophysics Data System (ADS)
Szombara, Stanisław
2015-12-01
The article presents a method that would compare skeletonisation methods for areal objects. The skeleton of an areal object, being its linear representation, is used, among others, in cartographic visualisation. The method allows us to compare between any skeletonisation methods in terms of the deviations of distance differences between the skeleton of the object and its border from one side and the distortions of skeletonisation from another. In the article, 5 methods were compared: Voronoi diagrams, densified Voronoi diagrams, constrained Delaunay triangulation, Straight Skeleton and Medial Axis (Transform). The results of comparison were presented on the example of several areal objects. The comparison of the methods showed that in all the analysed objects the Medial Axis (Transform) gives the smallest distortion and deviation values, which allows us to recommend it.
The influence of implant-abutment connection on the screw loosening and microleakage.
Tsuruta, Katsuhiro; Ayukawa, Yasunori; Matsuzaki, Tatsuya; Kihara, Masafumi; Koyano, Kiyoshi
2018-04-09
There are some spaces between abutment and implant body which can be a reservoir of toxic substance, and they can penetrate into subgingival space from microgap at the implant-abutment interface. This penetration may cause periimplantitis which is known to be one of the most important factors associated with late failure. In the present study, three kinds of abutment connection system, external parallel connection (EP), internal parallel connection (IP), and internal conical connection (CC), were studied from the viewpoint of microleakage from the gap between the implant and the abutment and in connection with the loosening of abutment screw. We observed dye leakage from abutment screw hole to outside through microgap under the excessive compressive and tensile load and evaluated the anti-leakage characteristics of these connection systems. During the experiment, one abutment screw for EP and two screws for IP, out of seven samples in each group, were fractured. After the 2000 cycles of compressive tensile loadings, removal torque value (RTV) of abutment screw represented no statistical differences among three groups. Standard deviation was largest in the RTV of EP and smallest in that of CC. The results of microleakage of toluidine blue from implant-abutment connection indicated that microleakage generally increased as loading procedure progressed. The amount of microleakage was almost plateau at 2000 cycles in CC, but still increasing in other two groups. The value of microleakage greatly scattered in EP, but the deviation of that in CC is significantly smaller. At 500 cycles of loading, there were no significant differences in the amount of microleakage among the groups, but at 1000, 1500, and 2000 cycles of loading, the amount of microleakage in CC was significantly smaller than that in IP. Throughout the experiment, the amount of microleakage in EP was largest, but no statistical difference was indicated due to the high standard deviation. Within the limitation of the present study, CC was stable even after the loading in the RTV of abutment screw and it prevented microleakage from the microgap between the implant body and the abutment, among the three tested connections.
Ding, Yao; Mohamed, Abdallah S R; Yang, Jinzhong; Colen, Rivka R; Frank, Steven J; Wang, Jihong; Wassal, Eslam Y; Wang, Wenjie; Kantor, Michael E; Balter, Peter A; Rosenthal, David I; Lai, Stephen Y; Hazle, John D; Fuller, Clifton D
2015-01-01
The purpose of this study was to investigate the potential of a head and neck magnetic resonance simulation and immobilization protocol on reducing motion-induced artifacts and improving positional variance for radiation therapy applications. Two groups (group 1, 17 patients; group 2, 14 patients) of patients with head and neck cancer were included under a prospective, institutional review board-approved protocol and signed informed consent. A 3.0-T magnetic resonance imaging (MRI) scanner was used for anatomic and dynamic contrast-enhanced acquisitions with standard diagnostic MRI setup for group 1 and radiation therapy immobilization devices for group 2 patients. The impact of magnetic resonance simulation/immobilization was evaluated qualitatively by 2 observers in terms of motion artifacts and positional reproducibility and quantitatively using 3-dimensional deformable registration to track intrascan maximum motion displacement of voxels inside 7 manually segmented regions of interest. The image quality of group 2 (29 examinations) was significantly better than that of group 1 (50 examinations) as rated by both observers in terms of motion minimization and imaging reproducibility (P < .0001). The greatest average maximum displacement was at the region of the larynx in the posterior direction for patients in group 1 (17 mm; standard deviation, 8.6 mm), whereas the smallest average maximum displacement was at the region of the posterior fossa in the superior direction for patients in group 2 (0.4 mm; standard deviation, 0.18 mm). Compared with group 1, maximum regional motion was reduced in group 2 patients in the oral cavity, floor of mouth, oropharynx, and larynx regions; however, the motion reduction reached statistical significance only in the regions of the oral cavity and floor of mouth (P < .0001). The image quality of head and neck MRI in terms of motion-related artifacts and positional reproducibility was greatly improved by use of radiation therapy immobilization devices. Consequently, immobilization with external and intraoral fixation in MRI examinations is required for radiation therapy application. Copyright © 2015 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
Adaptive Morphological Feature-Based Object Classifier for a Color Imaging System
NASA Technical Reports Server (NTRS)
McDowell, Mark; Gray, Elizabeth
2009-01-01
Utilizing a Compact Color Microscope Imaging System (CCMIS), a unique algorithm has been developed that combines human intelligence along with machine vision techniques to produce an autonomous microscope tool for biomedical, industrial, and space applications. This technique is based on an adaptive, morphological, feature-based mapping function comprising 24 mutually inclusive feature metrics that are used to determine the metrics for complex cell/objects derived from color image analysis. Some of the features include: Area (total numbers of non-background pixels inside and including the perimeter), Bounding Box (smallest rectangle that bounds and object), centerX (x-coordinate of intensity-weighted, center-of-mass of an entire object or multi-object blob), centerY (y-coordinate of intensity-weighted, center-of-mass, of an entire object or multi-object blob), Circumference (a measure of circumference that takes into account whether neighboring pixels are diagonal, which is a longer distance than horizontally or vertically joined pixels), . Elongation (measure of particle elongation given as a number between 0 and 1. If equal to 1, the particle bounding box is square. As the elongation decreases from 1, the particle becomes more elongated), . Ext_vector (extremal vector), . Major Axis (the length of a major axis of a smallest ellipse encompassing an object), . Minor Axis (the length of a minor axis of a smallest ellipse encompassing an object), . Partial (indicates if the particle extends beyond the field of view), . Perimeter Points (points that make up a particle perimeter), . Roundness [(4(pi) x area)/perimeter(squared)) the result is a measure of object roundness, or compactness, given as a value between 0 and 1. The greater the ratio, the rounder the object.], . Thin in center (determines if an object becomes thin in the center, (figure-eight-shaped), . Theta (orientation of the major axis), . Smoothness and color metrics for each component (red, green, blue) the minimum, maximum, average, and standard deviation within the particle are tracked. These metrics can be used for autonomous analysis of color images from a microscope, video camera, or digital, still image. It can also automatically identify tumor morphology of stained images and has been used to detect stained cell phenomena (see figure).
NASA Astrophysics Data System (ADS)
Geddes, Earl Russell
The details of the low frequency sound field for a rectangular room can be studied by the use of an established analytic technique--separation of variables. The solution is straightforward and the results are well-known. A non -rectangular room has boundary conditions which are not separable and therefore other solution techniques must be used. This study shows that the finite element method can be adapted for use in the study of sound fields in arbitrary shaped enclosures. The finite element acoustics problem is formulated and the modification of a standard program, which is necessary for solving acoustic field problems, is examined. The solution of the semi-non-rectangular room problem (one where the floor and ceiling remain parallel) is carried out by a combined finite element/separation of variables approach. The solution results are used to construct the Green's function for the low frequency sound field in five rooms (or data cases): (1) a rectangular (Louden) room; (2) The smallest wall of the Louden room canted 20 degrees from normal; (3) The largest wall of the Louden room canted 20 degrees from normal; (4) both the largest and the smallest walls are canted 20 degrees; and (5) a five-sided room variation of Case 4. Case 1, the rectangular room was calculated using both the finite element method and the separation of variables technique. The results for the two methods are compared in order to access the accuracy of the finite element method models. The modal damping coefficient are calculated and the results examined. The statistics of the source and receiver average normalized RMS P('2) responses in the 80 Hz, 100 Hz, and 125 Hz one-third octave bands are developed. The receiver averaged pressure response is developed to determine the effect of the source locations on the response. Twelve source locations are examined and the results tabulated for comparison. The effect of a finite sized source is looked at briefly. Finally, the standard deviation of the spatial pressure response is studied. The results for this characteristic show that it not significantly different in any of the rooms. The conclusions of the study are that only the frequency variations of the pressure response are affected by a room's shape. Further, in general, the simplest modification of a rectangular room (i.e., changing the angle of only one of the smallest walls), produces the most pronounced decrease of the pressure response variations in the low frequency region.
Abrasive Wear of Four Direct Restorative Materials by Standard and Whitening Dentifrices
2013-06-01
after an acidic challenge . Enamel loss was significantly greater when erosive and abrasive effects were combined. They concluded that acid-softened...surrounding soft tissues. Another benefit of restoration is the elimination of a challenging area for the patient and hygienist to clean. These areas...abrasion challenge ; the resin cement with the smallest sized filler particles had the smallest weight loss and maintained the smoothest surface of all the
NASA Astrophysics Data System (ADS)
Liao, Kaihua; Zhou, Zhiwen; Lai, Xiaoming; Zhu, Qing; Feng, Huihui
2017-04-01
The identification of representative soil moisture sampling sites is important for the validation of remotely sensed mean soil moisture in a certain area and ground-based soil moisture measurements in catchment or hillslope hydrological studies. Numerous approaches have been developed to identify optimal sites for predicting mean soil moisture. Each method has certain advantages and disadvantages, but they have rarely been evaluated and compared. In our study, surface (0-20 cm) soil moisture data from January 2013 to March 2016 (a total of 43 sampling days) were collected at 77 sampling sites on a mixed land-use (tea and bamboo) hillslope in the hilly area of Taihu Lake Basin, China. A total of 10 methods (temporal stability (TS) analyses based on 2 indices, K-means clustering based on 6 kinds of inputs and 2 random sampling strategies) were evaluated for determining optimal sampling sites for mean soil moisture estimation. They were TS analyses based on the smallest index of temporal stability (ITS, a combination of the mean relative difference and standard deviation of relative difference (SDRD)) and based on the smallest SDRD, K-means clustering based on soil properties and terrain indices (EFs), repeated soil moisture measurements (Theta), EFs plus one-time soil moisture data (EFsTheta), and the principal components derived from EFs (EFs-PCA), Theta (Theta-PCA), and EFsTheta (EFsTheta-PCA), and global and stratified random sampling strategies. Results showed that the TS based on the smallest ITS was better (RMSE = 0.023 m3 m-3) than that based on the smallest SDRD (RMSE = 0.034 m3 m-3). The K-means clustering based on EFsTheta (-PCA) was better (RMSE <0.020 m3 m-3) than these based on EFs (-PCA) and Theta (-PCA). The sampling design stratified by the land use was more efficient than the global random method. Forty and 60 sampling sites are needed for stratified sampling and global sampling respectively to make their performances comparable to the best K-means method (EFsTheta-PCA). Overall, TS required only one site, but its accuracy was limited. The best K-means method required <8 sites and yielded high accuracy, but extra soil and terrain information is necessary when using this method. The stratified sampling strategy can only be used if no pre-knowledge about soil moisture variation is available. This information will help in selecting the optimal methods for estimation the area mean soil moisture.
Kessler, Thomas; Neumann, Jörg; Mummendey, Amélie; Berthold, Anne; Schubert, Thomas; Waldzus, Sven
2010-09-01
To explain the determinants of negative behavior toward deviants (e.g., punishment), this article examines how people evaluate others on the basis of two types of standards: minimal and maximal. Minimal standards focus on an absolute cutoff point for appropriate behavior; accordingly, the evaluation of others varies dichotomously between acceptable or unacceptable. Maximal standards focus on the degree of deviation from that standard; accordingly, the evaluation of others varies gradually from positive to less positive. This framework leads to the prediction that violation of minimal standards should elicit punishment regardless of the degree of deviation, whereas punishment in response to violations of maximal standards should depend on the degree of deviation. Four studies assessed or manipulated the type of standard and degree of deviation displayed by a target. Results consistently showed the expected interaction between type of standard (minimal and maximal) and degree of deviation on punishment behavior.
Kusy, Maciej; Obrzut, Bogdan; Kluska, Jacek
2013-12-01
The aim of this article was to compare gene expression programming (GEP) method with three types of neural networks in the prediction of adverse events of radical hysterectomy in cervical cancer patients. One-hundred and seven patients treated by radical hysterectomy were analyzed. Each record representing a single patient consisted of 10 parameters. The occurrence and lack of perioperative complications imposed a two-class classification problem. In the simulations, GEP algorithm was compared to a multilayer perceptron (MLP), a radial basis function network neural, and a probabilistic neural network. The generalization ability of the models was assessed on the basis of their accuracy, the sensitivity, the specificity, and the area under the receiver operating characteristic curve (AUROC). The GEP classifier provided best results in the prediction of the adverse events with the accuracy of 71.96 %. Comparable but slightly worse outcomes were obtained using MLP, i.e., 71.87 %. For each of measured indices: accuracy, sensitivity, specificity, and the AUROC, the standard deviation was the smallest for the models generated by GEP classifier.
NASA Technical Reports Server (NTRS)
Abbott, T. S.; Moen, G. C.
1981-01-01
The weather radar cathode ray tube (CRT) is the prime candidate for presenting cockpit display of traffic information (CDTI) in current, conventionally equipped transport aircraft. Problems may result from this, since the CRT size is not optimized for CDTI applications and the CRT is not in the pilot's primary visual scan area. The impact of display size on the ability of pilots to utilize the traffic information to maintain a specified spacing interval behind a lead aircraft during an approach task was studied. The five display sizes considered are representative of the display hardware configurations of airborne weather radar systems. From a pilot's subjective workload viewpoint, even the smallest display size was usable for performing the self spacing task. From a performane viewpoint, the mean spacing values, which are indicative of how well the pilots were able to perform the task, exhibit the same trends, irrespective of display size; however, the standard deviation of the spacing intervals decreased (performance improves) as the display size increased. Display size, therefore, does have a significant effect on pilot performance.
Jacquemin, Denis; Moore, Barry; Planchat, Aurélien; Adamo, Carlo; Autschbach, Jochen
2014-04-08
Using a set of 40 conjugated molecules, we assess the performance of an "optimally tuned" range-separated hybrid functional in reproducing the experimental 0-0 energies. The selected protocol accounts for the impact of solvation using a corrected linear-response continuum approach and vibrational corrections through calculations of the zero-point energies of both ground and excited-states and provides basis set converged data thanks to the systematic use of diffuse-containing atomic basis sets at all computational steps. It turns out that an optimally tuned long-range corrected hybrid form of the Perdew-Burke-Ernzerhof functional, LC-PBE*, delivers both the smallest mean absolute error (0.20 eV) and standard deviation (0.15 eV) of all tested approaches, while the obtained correlation (0.93) is large but remains slightly smaller than its M06-2X counterpart (0.95). In addition, the efficiency of two other recently developed exchange-correlation functionals, namely SOGGA11-X and ωB97X-D, has been determined in order to allow more complete comparisons with previously published data.
Influence of scanning parameters on the estimation accuracy of control points of B-spline surfaces
NASA Astrophysics Data System (ADS)
Aichinger, Julia; Schwieger, Volker
2018-04-01
This contribution deals with the influence of scanning parameters like scanning distance, incidence angle, surface quality and sampling width on the average estimated standard deviations of the position of control points from B-spline surfaces which are used to model surfaces from terrestrial laser scanning data. The influence of the scanning parameters is analyzed by the Monte Carlo based variance analysis. The samples were generated for non-correlated and correlated data, leading to the samples generated by Latin hypercube and replicated Latin hypercube sampling algorithms. Finally, the investigations show that the most influential scanning parameter is the distance from the laser scanner to the object. The angle of incidence shows a significant effect for distances of 50 m and longer, while the surface quality contributes only negligible effects. The sampling width has no influence. Optimal scanning parameters can be found in the smallest possible object distance at an angle of incidence close to 0° in the highest surface quality. The consideration of correlations improves the estimation accuracy and underlines the importance of complete stochastic models for TLS measurements.
Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 1: January
NASA Astrophysics Data System (ADS)
Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.
1989-07-01
The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analyses produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of January. Included are global analyses of: (1) Mean temperature standard deviation; (2) Mean geopotential height standard deviation; (3) Mean density standard deviation; (4) Mean density standard deviation (all for 13 levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean dew point standard deviation for the 13 levels; and (6) Jet stream at levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.
Comparing Standard Deviation Effects across Contexts
ERIC Educational Resources Information Center
Ost, Ben; Gangopadhyaya, Anuj; Schiman, Jeffrey C.
2017-01-01
Studies using tests scores as the dependent variable often report point estimates in student standard deviation units. We note that a standard deviation is not a standard unit of measurement since the distribution of test scores can vary across contexts. As such, researchers should be cautious when interpreting differences in the numerical size of…
Mancia, G; Ferrari, A; Gregorini, L; Parati, G; Pomidossi, G; Bertinieri, G; Grassi, G; Zanchetti, A
1980-12-01
1. Intra-arterial blood pressure and heart rate were recorded for 24 h in ambulant hospitalized patients of variable age who had normal blood pressure or essential hypertension. Mean 24 h values, standard deviations and variation coefficient were obtained as the averages of values separately analysed for 48 consecutive half-hour periods. 2. In older subjects standard deviation and variation coefficient for mean arterial pressure were greater than in younger subjects with similar pressure values, whereas standard deviation and variation coefficient for mean arterial pressure were greater than in younger subjects with similar pressure values, whereas standard deviation aations and variation coefficient were obtained as the averages of values separately analysed for 48 consecurive half-hour periods. 2. In older subjects standard deviation and variation coefficient for mean arterial pressure were greater than in younger subjects with similar pressure values, whereas standard deviation and variation coefficient for heart rate were smaller. 3. In hypertensive subjects standard deviation for mean arterial pressure was greater than in normotensive subjects of similar ages, but this was not the case for variation coefficient, which was slightly smaller in the former than in the latter group. Normotensive and hypertensive subjects showed no difference in standard deviation and variation coefficient for heart rate. 4. In both normotensive and hypertensive subjects standard deviation and even more so variation coefficient were slightly or not related to arterial baroreflex sensitivity as measured by various methods (phenylephrine, neck suction etc.). 5. It is concluded that blood pressure variability increases and heart rate variability decreases with age, but that changes in variability are not so obvious in hypertension. Also, differences in variability among subjects are only marginally explained by differences in baroreflex function.
A new method for assessing the accuracy of full arch impressions in patients.
Kuhr, F; Schmidt, A; Rehmann, P; Wöstmann, B
2016-12-01
To evaluate a new method of measuring the real deviation (trueness) of full arch impressions intraorally and to investigate the trueness of digital full arch impressions in comparison to a conventional impression procedure in clinical use. Four metal spheres were fixed with composite using a metal application aid to the lower teeth of 50 test subjects as reference structures. One conventional impression (Impregum Penta Soft) with subsequent type-IV gypsum model casting (CI) and three different digital impressions were performed in the lower jaw of each test person with the following intraoral scanners: Sirona CEREC Omnicam (OC), 3M True Definition (TD), Heraeus Cara TRIOS (cT). The digital and conventional (gypsum) models were analyzed relative to the spheres. Linear distance and angle measurements between the spheres, as well as digital superimpositions of the spheres with the reference data set were executed. With regard to the distance measurements, CI showed the smallest deviations followed by intraoral scanners TD, cT and OC. A digital superimposition procedure yielded the same order for the outcomes: CI (15±4μm), TD (23±9μm), cT (37±14μm), OC (214±38μm). Angle measurements revealed the smallest deviation for TD (0.06°±0,07°) followed by CI (0.07°±0.07°), cT (0.13°±0.15°) and OC (0.28°±0.21°). The new measuring method is suitable for measuring the dimensional accuracy of full arch impressions intraorally. CI is still significantly more accurate than full arch scans with intraoral scanners in clinical use. Conventional full arch impressions with polyether impression materials are still more accurate than full arch digital impressions. Digital impression systems using powder application and active wavefront sampling technology achieve the most accurate results in comparison to other intraoral scanning systems (DRKS-ID: DRKS00009360, German Clinical Trials Register). Copyright © 2016 Elsevier Ltd. All rights reserved.
Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 7: July
NASA Astrophysics Data System (ADS)
Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.
1989-07-01
The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analysis produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of July. Included are global analyses of: (1) Mean temperature/standard deviation; (2) Mean geopotential height/standard deviation; (3) Mean density/standard deviation; (4) Height and vector standard deviation (all at 13 pressure levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean dew point standard deviation at levels 1000 through 30 mb; and (6) Jet stream at levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.
Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 10: October
NASA Astrophysics Data System (ADS)
Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.
1989-07-01
The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analysis produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of October. Included are global analyses of: (1) Mean temperature/standard deviation; (2) Mean geopotential height/standard deviation; (3) Mean density/standard deviation; (4) Height and vector standard deviation (all at 13 pressure levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean dew point/standard deviation at levels 1000 through 30 mb; and (6) Jet stream at levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.
Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 3: March
NASA Astrophysics Data System (ADS)
Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.
1989-11-01
The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analysis produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of March. Included are global analyses of: (1) Mean Temperature Standard Deviation; (2) Mean Geopotential Height Standard Deviation; (3) Mean Density Standard Deviation; (4) Height and Vector Standard Deviation (all for 13 pressure levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean Dew Point Standard Deviation for levels 1000 through 30 mb; and (6) Jet stream for levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.
Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 2: February
NASA Astrophysics Data System (ADS)
Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.
1989-09-01
The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analyses produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of February. Included are global analyses of: (1) Mean temperature standard deviation; (2) Mean geopotential height standard deviation; (3) Mean density standard deviation; (4) Height and vector standard deviation (all for 13 pressure levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean dew point standard deviation for the 13 levels; and (6) Jet stream for levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.
Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 4: April
NASA Astrophysics Data System (ADS)
Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.
1989-07-01
The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analyses produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of April. Included are global analyses of: (1) Mean temperature standard deviation; (2) Mean geopotential height standard deviation; (3) Mean density standard deviation; (4) Height and vector standard deviation (all for 13 pressure levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean dew point standard deviation for the 13 levels; and (6) Jet stream for levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.
DeSantis, Michael C; DeCenzo, Shawn H; Li, Je-Luen; Wang, Y M
2010-03-29
Standard deviation measurements of intensity profiles of stationary single fluorescent molecules are useful for studying axial localization, molecular orientation, and a fluorescence imaging system's spatial resolution. Here we report on the analysis of the precision of standard deviation measurements of intensity profiles of single fluorescent molecules imaged using an EMCCD camera.We have developed an analytical expression for the standard deviation measurement error of a single image which is a function of the total number of detected photons, the background photon noise, and the camera pixel size. The theoretical results agree well with the experimental, simulation, and numerical integration results. Using this expression, we show that single-molecule standard deviation measurements offer nanometer precision for a large range of experimental parameters.
NASA Astrophysics Data System (ADS)
Tanoto, Yopi Y.; Anggono, Juliana; Siahaan, Ian H.; Budiman, Wesley
2017-01-01
There are several parameters that must be set before manufacturing a product using 3D printing. These parameters include the orientation deposition of that product, type of material, form fill, fill density, and other parameters. The finished product of 3D printing has some responses that can be observed, measured, and tested. Some of those responses are the processing time, the dimensions of the end product, its surface roughness and the mechanical properties, i.e. its yield strength, ultimate tensile strength, and impact resistance. This research was conducted to study the relationship between process parameters of 3D printing machine using a technology of fused deposition modeling (FDM) and the generated responses. The material used was ABS plastic that was commonly used in the industry. Understanding the relationship between the parameters and the responses thus the resulting product can be manufactured to meet the user needs. Three different orientations in depositing the ABS polymer named XY(first orientation), YX (second orientation), and ZX (third orientation) were studied. Processing time, dimensional accuracy, and the product strength were the responses that were measured and tested. The study reports that the printing process with third orientation was the fastest printing process with the processing time 2432 seconds followed by orientation 1 and 2 with a processing time of 2688 and 2780 seconds respectively. Dimension accuracy was also measured from the width and the length of gauge area of tensile test specimens printed in comparison with the dimensions required by ASTM 638-02. It was found that the smallest difference was in thickness dimension, i.e. 0.1 mm thicker in printed sample using second orientation than as required by the standard. The smallest thickness deviation from the standard was measured in width dimension of a sample printed using first orientation (0.13 mm). As with the length dimension, the closest dimension to the standard was resulted from the third orientation product, i.e 0.2 mm. Tensile test done on all the specimens produced with those three orientations shows that the highest tensile strength was obtained in sample from second orientation deposition, i.e. 7.66 MPa followed by the first and third orientations products, i.e. 6.8 MPa and 3.31 MPa, respectively.
Exploring Students' Conceptions of the Standard Deviation
ERIC Educational Resources Information Center
delMas, Robert; Liu, Yan
2005-01-01
This study investigated introductory statistics students' conceptual understanding of the standard deviation. A computer environment was designed to promote students' ability to coordinate characteristics of variation of values about the mean with the size of the standard deviation as a measure of that variation. Twelve students participated in an…
7 CFR 801.4 - Tolerances for dockage testers.
Code of Federal Regulations, 2012 CFR
2012-01-01
....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...
7 CFR 801.4 - Tolerances for dockage testers.
Code of Federal Regulations, 2014 CFR
2014-01-01
....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...
7 CFR 801.4 - Tolerances for dockage testers.
Code of Federal Regulations, 2011 CFR
2011-01-01
....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...
7 CFR 801.4 - Tolerances for dockage testers.
Code of Federal Regulations, 2013 CFR
2013-01-01
....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...
Statistics as Unbiased Estimators: Exploring the Teaching of Standard Deviation
ERIC Educational Resources Information Center
Wasserman, Nicholas H.; Casey, Stephanie; Champion, Joe; Huey, Maryann
2017-01-01
This manuscript presents findings from a study about the knowledge for and planned teaching of standard deviation. We investigate how understanding variance as an unbiased (inferential) estimator--not just a descriptive statistic for the variation (spread) in data--is related to teachers' instruction regarding standard deviation, particularly…
7 CFR 801.4 - Tolerances for dockage testers.
Code of Federal Regulations, 2010 CFR
2010-01-01
....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...
7 CFR 801.6 - Tolerances for moisture meters.
Code of Federal Regulations, 2010 CFR
2010-01-01
... moisture, mean deviation from National standard moisture meter using Hard Red Winter wheat Mid ±0.05 percent moisture, mean deviation from National standard moisture meter using Hard Red Winter wheat High ±0.05 percent moisture, mean deviation from National standard moisture meter using Hard Red Winter wheat...
In vitro marginal fit of three all-ceramic crown systems.
Yeo, In-Sung; Yang, Jae-Ho; Lee, Jai-Bong
2003-11-01
Studies on marginal discrepancies of single restorations using various systems and materials have resulted in statistical inferences that are ambiguous because of small sample sizes and limited numbers of measurements per specimen. The purpose of this study was to compare the marginal adaptation of single anterior restorations made using different systems. The in vitro marginal discrepancies of 3 different all-ceramic crown systems (Celay In-Ceram, conventional In-Ceram, and IPS Empress 2 layering technique), and a control group of metal ceramic restorations were evaluated and compared by measuring the gap dimension between the crowns and the prepared tooth at the marginal opening. The crowns were made for 1 extracted maxillary central incisor prepared with a 1-mm shoulder margin and 6-degree tapered walls by milling. Thirty crowns per system were fabricated. Crown measurements were recorded with an optical microscope, with an accuracy of +/-0.1 microm, at 50 points spaced approximately 400 microm along the circumferential margin. The criterion of 120 microm was used as the maximum clinically acceptable marginal gap. Mean gap dimensions and standard deviations were calculated for marginal opening. The data were analyzed with a 1-way analysis of variance (alpha=.05). Mean gap dimensions and standard deviations at the marginal opening for the incisor crowns were 87 +/- 34 microm for control, 83 +/- 33 microm for Celay In-Ceram, 112 +/- 55 microm for conventional In-Ceram, and 46 +/- 16 microm for the IPS Empress 2 layering technique. Significant differences were found among the crown groups (P<.05). Compared with the control group, the IPS Empress 2 group had significantly smaller marginal discrepancies (P<.05), and the conventional In-Ceram group exhibited significantly greater marginal discrepancies (P<.05). There was no significant difference between the Celay In-Ceram and the control group. Within the limitations of this study, the marginal discrepancies were all within the clinically acceptable standard set at 120 microm. However, the IPS Empress 2 system showed the smallest and most homogeneous gap dimension, whereas the conventional In-Ceram system presented the largest and more variable gap dimension compared with the metal ceramic (control) restoration.
Peng, Lingling; Li, Yi; Feng, Hao
2017-07-14
Reference crop evapotranspiration (ET o ) is a critically important parameter for climatological, hydrological and agricultural management. The FAO56 Penman-Monteith (PM) equation has been recommended as the standardized ET o (ET o,s ) equation, but it has a high requirements of climatic data. There is a practical need for finding a best alternative method to estimate ET o in the regions where full climatic data are lacking. A comprehensive comparison for the spatiotemporal variations, relative errors, standard deviations and Nash-Sutcliffe efficacy coefficients of monthly or annual ET o,s and ET o,i (i = 1, 2, …, 10) values estimated by 10 selected methods (i.e., Irmak et al., Makkink, Priestley-Taylor, Hargreaves-Samani, Droogers-Allen, Berti et al., Doorenbos-Pruitt, Wright and Valiantzas, respectively) using data at 552 sites over 1961-2013 in mainland China. The method proposed by Berti et al. (2014) was selected as the best alternative of FAO56-PM because it was simple in computation process, only utilized temperature data, had generally good accuracy in describing spatiotemporal characteristics of ET o,s in different sub-regions and mainland China, and correlated linearly to the FAO56-PM method very well. The parameters of the linear correlations between ET o of the two methods are calibrated for each site with the smallest determination of coefficient being 0.87.
Universal Scaling Laws for Dense Particle Suspensions in Turbulent Wall-Bounded Flows.
Costa, Pedro; Picano, Francesco; Brandt, Luca; Breugem, Wim-Paul
2016-09-23
The macroscopic behavior of dense suspensions of neutrally buoyant spheres in turbulent plane channel flow is examined. We show that particles larger than the smallest turbulence scales cause the suspension to deviate from the continuum limit in which its dynamics is well described by an effective suspension viscosity. This deviation is caused by the formation of a particle layer close to the wall with significant slip velocity. By assuming two distinct transport mechanisms in the near-wall layer and the turbulence in the bulk, we define an effective wall location such that the flow in the bulk can still be accurately described by an effective suspension viscosity. We thus propose scaling laws for the mean velocity profile of the suspension flow, together with a master equation able to predict the increase in drag as a function of the particle size and volume fraction.
Visualizing the Sample Standard Deviation
ERIC Educational Resources Information Center
Sarkar, Jyotirmoy; Rashid, Mamunur
2017-01-01
The standard deviation (SD) of a random sample is defined as the square-root of the sample variance, which is the "mean" squared deviation of the sample observations from the sample mean. Here, we interpret the sample SD as the square-root of twice the mean square of all pairwise half deviations between any two sample observations. This…
Kokubo, Tetsuro; Hashimoto, Takeshi; Suda, Yasunori; Waseda, Akeo; Ikezawa, Hiroko
2017-12-01
Second metatarsophalangeal (MTP) joint dislocation is associated with hallux valgus, and the treatment of complete dislocation can be difficult. The purpose of this study was to radiographically clarify the characteristic foot shape in the presence of second MTP joint dislocation. Weight-bearing foot radiographs of the 268 patients (358 feet) with hallux valgus were examined. They were divided into 2 groups: those with second MTP joint dislocation (study group = 179 feet) and those without dislocation (control group = 179 feet). Parameters measured included the hallux valgus angle (HVA), first-second intermetatarsal angle (IMA), second MTP joint angle, hallux interphalangeal angle (IPA), second metatarsal protrusion distance (MPD), metatarsus adductus angle (MAA), and the second metatarsal declination angle (2MDA). Furthermore, the dislocation group was divided into 3 subgroups according to second toe deviation direction: group M (medial type), group N (neutral type), and group L (lateral type). The IPA and the 2MDA were significantly greater in the study group than in the control group. By multiple comparison analysis, the IMA was greatest in group M and smallest in group L. The IPA was smaller and 2MDA greater in group N than in group L. The HVA and MAA in group L were greatest, and MPD in group L was smallest. The patients with second MTP joint dislocation associated with hallux valgus had greater hallux interphalangeal joint varus and a second metatarsal more inclined than with hallux valgus alone. The second toe deviated in a different direction according to the foot shape. Level III, retrospective comparative study.
Dopkins, Stephen; Varner, Kaitlin; Hoyer, Darin
2017-10-01
In word recognition semantic priming of test words increased the false-alarm rate and the mean of confidence ratings to lures. Such priming also increased the standard deviation of confidence ratings to lures and the slope of the z-ROC function, suggesting that the priming increased the standard deviation of the lure evidence distribution. The Unequal Variance Signal Detection (UVSD) model interpreted the priming as increasing the standard deviation of the lure evidence distribution. Without additional parameters the Dual Process Signal Detection (DPSD) model could only accommodate the results by fitting the data for related and unrelated primes separately, interpreting the priming, implausibly, as decreasing the probability of target recollection (DPSD). With an additional parameter, for the probability of false (lure) recollection the model could fit the data for related and unrelated primes together, interpreting the priming as increasing the probability of false recollection. These results suggest that DPSD estimates of target recollection probability will decrease with increases in the lure confidence/evidence standard deviation unless a parameter is included for false recollection. Unfortunately the size of a given lure confidence/evidence standard deviation relative to other possible lure confidence/evidence standard deviations is often unspecified by context. Hence the model often has no way of estimating false recollection probability and thereby correcting its estimates of target recollection probability.
Down-Looking Interferometer Study II, Volume I,
1980-03-01
g(standard deviation of AN )(standard deviation of(3) where T’rm is the "reference spectrum", an estimate of the actual spectrum v gv T ’V Cgv . If jpj...spectrum T V . cgv . According to Eq. (2), Z is the standard deviation of the observed contrast spectral radiance AN divided by the effective rms system
40 CFR 61.207 - Radium-226 sampling and measurement procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... B, Method 114. (3) Calculate the mean, x 1, and the standard deviation, s 1, of the n 1 radium-226... owner or operator of a phosphogypsum stack shall report the mean, standard deviation, 95th percentile..., Method 114. (4) Recalculate the mean and standard deviation of the entire set of n 2 radium-226...
NASA Astrophysics Data System (ADS)
Fyta, Maria; Netz, Roland R.
2012-03-01
Using molecular dynamics (MD) simulations in conjunction with the SPC/E water model, we optimize ionic force-field parameters for seven different halide and alkali ions, considering a total of eight ion-pairs. Our strategy is based on simultaneous optimizing single-ion and ion-pair properties, i.e., we first fix ion-water parameters based on single-ion solvation free energies, and in a second step determine the cation-anion interaction parameters (traditionally given by mixing or combination rules) based on the Kirkwood-Buff theory without modification of the ion-water interaction parameters. In doing so, we have introduced scaling factors for the cation-anion Lennard-Jones (LJ) interaction that quantify deviations from the standard mixing rules. For the rather size-symmetric salt solutions involving bromide and chloride ions, the standard mixing rules work fine. On the other hand, for the iodide and fluoride solutions, corresponding to the largest and smallest anion considered in this work, a rescaling of the mixing rules was necessary. For iodide, the experimental activities suggest more tightly bound ion pairing than given by the standard mixing rules, which is achieved in simulations by reducing the scaling factor of the cation-anion LJ energy. For fluoride, the situation is different and the simulations show too large attraction between fluoride and cations when compared with experimental data. For NaF, the situation can be rectified by increasing the cation-anion LJ energy. For KF, it proves necessary to increase the effective cation-anion Lennard-Jones diameter. The optimization strategy outlined in this work can be easily adapted to different kinds of ions.
Briehl, Margaret M; Nelson, Mark A; Krupinski, Elizabeth A; Erps, Kristine A; Holcomb, Michael J; Weinstein, John B; Weinstein, Ronald S
2016-01-01
Faculty members from the Department of Pathology at The University of Arizona College of Medicine-Tucson have offered a 4-credit course on enhanced general pathology for graduate students since 1996. The course is titled, "Mechanisms of Human Disease." Between 1997 and 2016, 270 graduate students completed Mechanisms of Human Disease. The students came from 21 programs of study. Analysis of Variance, using course grade as the dependent and degree, program, gender, and year (1997-2016) as independent variables, indicated that there was no significant difference in final grade (F = 0.112; P = .8856) as a function of degree (doctorate: mean = 89.60, standard deviation = 5.75; master's: mean = 89.34, standard deviation = 6.00; certificate program: mean = 88.64, standard deviation = 8.25), specific type of degree program (F = 2.066, P = .1316; life sciences: mean = 89.95, standard deviation = 6.40; pharmaceutical sciences: mean = 90.71, standard deviation = 4.57; physical sciences: mean = 87.79, standard deviation = 5.17), or as a function of gender (F = 2.96, P = .0865; males: mean = 88.09, standard deviation = 8.36; females: mean = 89.58, standard deviation = 5.82). Students in the physical and life sciences performed equally well. Mechanisms of Human Disease is a popular course that provides students enrolled in a variety of graduate programs with a medical school-based course on mechanisms of diseases. The addition of 2 new medically oriented Master of Science degree programs has nearly tripled enrollment. This graduate level course also potentially expands the interdisciplinary diversity of participants in our interprofessional education and collaborative practice exercises.
Briehl, Margaret M.; Nelson, Mark A.; Krupinski, Elizabeth A.; Erps, Kristine A.; Holcomb, Michael J.; Weinstein, John B.
2016-01-01
Faculty members from the Department of Pathology at The University of Arizona College of Medicine-Tucson have offered a 4-credit course on enhanced general pathology for graduate students since 1996. The course is titled, “Mechanisms of Human Disease.” Between 1997 and 2016, 270 graduate students completed Mechanisms of Human Disease. The students came from 21 programs of study. Analysis of Variance, using course grade as the dependent and degree, program, gender, and year (1997-2016) as independent variables, indicated that there was no significant difference in final grade (F = 0.112; P = .8856) as a function of degree (doctorate: mean = 89.60, standard deviation = 5.75; master’s: mean = 89.34, standard deviation = 6.00; certificate program: mean = 88.64, standard deviation = 8.25), specific type of degree program (F = 2.066, P = .1316; life sciences: mean = 89.95, standard deviation = 6.40; pharmaceutical sciences: mean = 90.71, standard deviation = 4.57; physical sciences: mean = 87.79, standard deviation = 5.17), or as a function of gender (F = 2.96, P = .0865; males: mean = 88.09, standard deviation = 8.36; females: mean = 89.58, standard deviation = 5.82). Students in the physical and life sciences performed equally well. Mechanisms of Human Disease is a popular course that provides students enrolled in a variety of graduate programs with a medical school-based course on mechanisms of diseases. The addition of 2 new medically oriented Master of Science degree programs has nearly tripled enrollment. This graduate level course also potentially expands the interdisciplinary diversity of participants in our interprofessional education and collaborative practice exercises. PMID:28725783
Oechsner, Markus; Chizzali, Barbara; Devecka, Michal; Combs, Stephanie Elisabeth; Wilkens, Jan Jakob; Duma, Marciana Nona
2016-10-26
The aim of this study was to analyze differences in couch shifts (setup errors) resulting from image registration of different CT datasets with free breathing cone beam CTs (FB-CBCT). As well automatic as manual image registrations were performed and registration results were correlated to tumor characteristics. FB-CBCT image registration was performed for 49 patients with lung lesions using slow planning CT (PCT), average intensity projection (AIP), maximum intensity projection (MIP) and mid-ventilation CTs (MidV) as reference images. Both, automatic and manual image registrations were applied. Shift differences were evaluated between the registered CT datasets for automatic and manual registration, respectively. Furthermore, differences between automatic and manual registration were analyzed for the same CT datasets. The registration results were statistically analyzed and correlated to tumor characteristics (3D tumor motion, tumor volume, superior-inferior (SI) distance, tumor environment). Median 3D shift differences over all patients were between 0.5 mm (AIPvsMIP) and 1.9 mm (MIPvsPCT and MidVvsPCT) for the automatic registration and between 1.8 mm (AIPvsPCT) and 2.8 mm (MIPvsPCT and MidVvsPCT) for the manual registration. For some patients, large shift differences (>5.0 mm) were found (maximum 10.5 mm, automatic registration). Comparing automatic vs manual registrations for the same reference CTs, ∆AIP achieved the smallest (1.1 mm) and ∆MIP the largest (1.9 mm) median 3D shift differences. The standard deviation (variability) for the 3D shift differences was also the smallest for ∆AIP (1.1 mm). Significant correlations (p < 0.01) between 3D shift difference and 3D tumor motion (AIPvsMIP, MIPvsMidV) and SI distance (AIPvsMIP) (automatic) and also for 3D tumor motion (∆PCT, ∆MidV; automatic vs manual) were found. Using different CT datasets for image registration with FB-CBCTs can result in different 3D couch shifts. Manual registrations achieved partly different 3D shifts than automatic registrations. AIP CTs yielded the smallest shift differences and might be the most appropriate CT dataset for registration with 3D FB-CBCTs.
7 CFR 51.308 - Methods of sampling and calculation of percentages.
Code of Federal Regulations, 2012 CFR
2012-01-01
..., CERTIFICATION, AND STANDARDS) United States Standards for Grades of Apples Methods of Sampling and Calculation... where the minimum diameter of the smallest apple does not vary more than 1/2 inch from the minimum diameter of the largest apple, percentages shall be calculated on the basis of count. (b) In all other...
7 CFR 51.308 - Methods of sampling and calculation of percentages.
Code of Federal Regulations, 2011 CFR
2011-01-01
..., CERTIFICATION, AND STANDARDS) United States Standards for Grades of Apples Methods of Sampling and Calculation... where the minimum diameter of the smallest apple does not vary more than 1/2 inch from the minimum diameter of the largest apple, percentages shall be calculated on the basis of count. (b) In all other...
7 CFR 51.308 - Methods of sampling and calculation of percentages.
Code of Federal Regulations, 2010 CFR
2010-01-01
..., CERTIFICATION, AND STANDARDS) United States Standards for Grades of Apples Methods of Sampling and Calculation... where the minimum diameter of the smallest apple does not vary more than 1/2 inch from the minimum diameter of the largest apple, percentages shall be calculated on the basis of count. (b) In all other...
Variations of archived static-weight data and WIM
DOE Office of Scientific and Technical Information (OSTI.GOV)
Elliott, C.J.; Gillmann, R.; Kent, P.M.
1998-12-01
Using seven-card archived, static-weight and weigh-in-motion (WIM), truck data received by FHWA for 1966--1992, the authors examine the fluctuations of four fiducial weight measures reported at weight sites in the 50 states. The reduced 172 MB Class 9 (332000) database was prepared and ordered from 2 CD-ROMS with duplicate records removed. Front-axle weight and gross-vehicle weight (GVW) are combined conceptually by determining the front axle weight in four-quartile GVW categories. The four categories of front axle weight from the four GVW categories are combined in four ways. Three linear combinations are with fixed-coefficient fiducials and one is that optimal linearmore » combination producing the smallest standard deviation to mean value ratio. The best combination gives coefficients of variation of 2--3% for samples of 100 trucks, below the expected accuracy of single-event WIM measurements. Time tracking of data shows some high-variation sites have seasonal variations, or linear variations over the time-ordered samples. Modeling of these effects is very site specific but provides a way to reduce high variations. Some automatic calibration schemes would erroneously remove such seasonal or linear variations were they static effects.« less
Liu, Yi-hong; Feng, Hai-lan; Bao, Yi-wang; Qiu, Yan
2007-02-18
To evaluate the effect of core:dentin thickness ratio on the flexure strength, fracture mode and origin of bilayered IPS Empress II ceramic composite specimens. IPS Empress II core ceramic, dentin porcelain and bilayered composite specimens with core:dentin thickness ratio of 2:1 and 1:1 were tested in three-point flexure strength. Mean strengths and standard deviations were determined. The optical microscopy was employed for identification of the fracture mode and origin. The flexure strength of dentin porcelain was the smallest(62.7 MPa), and the strength of bilayered composite specimens was smaller than single-layered core ceramic(190.2 MPa). The core: dentin ratio did not influence the strength of bilayered composite specimens. The frequency of occurrence of bilayered specimen delaminations was higher in the group of core: dentin thickness ratio of 1:1 than in the group of 2:1. IPS Empress II core ceramic was significantly stronger than veneering dentin porcelain. Core:dentin thickness ratio could significantly influence the fracture mode and origin, and bilayered IPS Empress II ceramic composite specimens showed little influence in the fracture strength.
A Note on Standard Deviation and Standard Error
ERIC Educational Resources Information Center
Hassani, Hossein; Ghodsi, Mansoureh; Howell, Gareth
2010-01-01
Many students confuse the standard deviation and standard error of the mean and are unsure which, if either, to use in presenting data. In this article, we endeavour to address these questions and cover some related ambiguities about these quantities.
Bolann, B J; Asberg, A
2004-01-01
The deviation of test results from patients' homeostatic set points in steady-state conditions may complicate interpretation of the results and the comparison of results with clinical decision limits. In this study the total deviation from the homeostatic set point is defined as the maximum absolute deviation for 95% of measurements, and we present analytical quality requirements that prevent analytical error from increasing this deviation to more than about 12% above the value caused by biology alone. These quality requirements are: 1) The stable systematic error should be approximately 0, and 2) a systematic error that will be detected by the control program with 90% probability, should not be larger than half the value of the combined analytical and intra-individual standard deviation. As a result, when the most common control rules are used, the analytical standard deviation may be up to 0.15 times the intra-individual standard deviation. Analytical improvements beyond these requirements have little impact on the interpretability of measurement results.
Code of Federal Regulations, 2010 CFR
2010-01-01
... defined in section 1 of this appendix is as follows: (a) The standard deviation of lateral track errors shall be less than 6.3 NM (11.7 Km). Standard deviation is a statistical measure of data about a mean... standard deviation about the mean encompasses approximately 68 percent of the data and plus or minus 2...
Lin, P.-S.; Chiou, B.; Abrahamson, N.; Walling, M.; Lee, C.-T.; Cheng, C.-T.
2011-01-01
In this study, we quantify the reduction in the standard deviation for empirical ground-motion prediction models by removing ergodic assumption.We partition the modeling error (residual) into five components, three of which represent the repeatable source-location-specific, site-specific, and path-specific deviations from the population mean. A variance estimation procedure of these error components is developed for use with a set of recordings from earthquakes not heavily clustered in space.With most source locations and propagation paths sampled only once, we opt to exploit the spatial correlation of residuals to estimate the variances associated with the path-specific and the source-location-specific deviations. The estimation procedure is applied to ground-motion amplitudes from 64 shallow earthquakes in Taiwan recorded at 285 sites with at least 10 recordings per site. The estimated variance components are used to quantify the reduction in aleatory variability that can be used in hazard analysis for a single site and for a single path. For peak ground acceleration and spectral accelerations at periods of 0.1, 0.3, 0.5, 1.0, and 3.0 s, we find that the singlesite standard deviations are 9%-14% smaller than the total standard deviation, whereas the single-path standard deviations are 39%-47% smaller.
A better norm-referenced grading using the standard deviation criterion.
Chan, Wing-shing
2014-01-01
The commonly used norm-referenced grading assigns grades to rank-ordered students in fixed percentiles. It has the disadvantage of ignoring the actual distance of scores among students. A simple norm-referenced grading via standard deviation is suggested for routine educational grading. The number of standard deviation of a student's score from the class mean was used as the common yardstick to measure achievement level. Cumulative probability of a normal distribution was referenced to help decide the amount of students included within a grade. RESULTS of the foremost 12 students from a medical examination were used for illustrating this grading method. Grading by standard deviation seemed to produce better cutoffs in allocating an appropriate grade to students more according to their differential achievements and had less chance in creating arbitrary cutoffs in between two similarly scored students than grading by fixed percentile. Grading by standard deviation has more advantages and is more flexible than grading by fixed percentile for norm-referenced grading.
Johnson, Craig W; Johnson, Ronald; Kim, Mira; McKee, John C
2009-11-01
During 2004 and 2005 orientations, all 187 and 188 new matriculates, respectively, in two southwestern U.S. nursing schools completed Personal Background and Preparation Surveys (PBPS) in the first predictive validity study of a diagnostic and prescriptive instrument for averting adverse academic status events (AASE) among nursing or health science professional students. One standard deviation increases in PBPS risks (p < 0.05) multiplied odds of first-year or second-year AASE by approximately 150%, controlling for school affiliation and underrepresented minority student (URMS) status. AASE odds one standard deviation above mean were 216% to 250% those one standard deviation below mean. Odds of first-year or second-year AASE for URMS one standard deviation above the 2004 PBPS mean were 587% those for non-URMS one standard deviation below mean. The PBPS consistently and significantly facilitated early identification of nursing students at risk for AASE, enabling proactive targeting of interventions for risk amelioration and AASE or attrition prevention. Copyright 2009, SLACK Incorporated.
9 CFR 113.454 - Clostridium Perfringens Type C Antitoxin.
Code of Federal Regulations, 2011 CFR
2011-01-01
... sickness or death in injected mice. (iii) L + dose. The smallest quantity of toxin which can be mixed with one unit of Standard Antitoxin and cause death in at least 80 percent of injected mice. (iv) Standard... of mice can be made. (vi) Five Swiss white mice, each weighing 16-20 grams, shall be used for each...
Demonstration of the Gore Module for Passive Ground Water Sampling
2014-06-01
ix ACRONYMS AND ABBREVIATIONS % RSD percent relative standard deviation 12DCA 1,2-dichloroethane 112TCA 1,1,2-trichloroethane 1122TetCA...Analysis of Variance ROD Record of Decision RSD relative standard deviation SBR Southern Bush River SVOC semi-volatile organic compound...replicate samples had a relative standard deviation ( RSD ) that was 20% or less. For the remaining analytes (PCE, cDCE, and chloroform), at least 70
Wang, Anxin; Li, Zhifang; Yang, Yuling; Chen, Guojuan; Wang, Chunxue; Wu, Yuntao; Ruan, Chunyu; Liu, Yan; Wang, Yilong; Wu, Shouling
2016-01-01
To investigate the relationship between baseline systolic blood pressure (SBP) and visit-to-visit blood pressure variability in a general population. This is a prospective longitudinal cohort study on cardiovascular risk factors and cardiovascular or cerebrovascular events. Study participants attended a face-to-face interview every 2 years. Blood pressure variability was defined using the standard deviation and coefficient of variation of all SBP values at baseline and follow-up visits. The coefficient of variation is the ratio of the standard deviation to the mean SBP. We used multivariate linear regression models to test the relationships between SBP and standard deviation, and between SBP and coefficient of variation. Approximately 43,360 participants (mean age: 48.2±11.5 years) were selected. In multivariate analysis, after adjustment for potential confounders, baseline SBPs <120 mmHg were inversely related to standard deviation (P<0.001) and coefficient of variation (P<0.001). In contrast, baseline SBPs ≥140 mmHg were significantly positively associated with standard deviation (P<0.001) and coefficient of variation (P<0.001). Baseline SBPs of 120-140 mmHg were associated with the lowest standard deviation and coefficient of variation. The associations between baseline SBP and standard deviation, and between SBP and coefficient of variation during follow-ups showed a U curve. Both lower and higher baseline SBPs were associated with increased blood pressure variability. To control blood pressure variability, a good target SBP range for a general population might be 120-139 mmHg.
Weinstein, Ronald S; Krupinski, Elizabeth A; Weinstein, John B; Graham, Anna R; Barker, Gail P; Erps, Kristine A; Holtrust, Angelette L; Holcomb, Michael J
2016-01-01
A medical school general pathology course has been reformatted into a K-12 general pathology course. This new course has been implemented at a series of 7 to 12 grade levels and the student outcomes compared. Typically, topics covered mirrored those in a medical school general pathology course serving as an introduction to the mechanisms of diseases. Assessment of student performance was based on their score on a multiple-choice final examination modeled after an examination given to medical students. Two Tucson area schools, in a charter school network, participated in the study. Statistical analysis of examination performances showed that there were no significant differences as a function of school ( F = 0.258, P = .6128), with students at school A having an average test scores of 87.03 (standard deviation = 8.99) and school B 86.00 (standard deviation = 8.18; F = 0.258, P = .6128). Analysis of variance was also conducted on the test scores as a function of gender and class grade. There were no significant differences as a function of gender ( F = 0.608, P = .4382), with females having an average score of 87.18 (standard deviation = 7.24) and males 85.61 (standard deviation = 9.85). There were also no significant differences as a function of grade level ( F = 0.627, P = .6003), with 7th graders having an average of 85.10 (standard deviation = 8.90), 8th graders 86.00 (standard deviation = 9.95), 9th graders 89.67 (standard deviation = 5.52), and 12th graders 86.90 (standard deviation = 7.52). The results demonstrated that middle and upper school students performed equally well in K-12 general pathology. Student course evaluations showed that the course met the student's expectations. One class voted K-12 general pathology their "elective course-of-the-year."
Wan, Xiang; Wang, Wenqian; Liu, Jiming; Tong, Tiejun
2014-12-19
In systematic reviews and meta-analysis, researchers often pool the results of the sample mean and standard deviation from a set of similar clinical trials. A number of the trials, however, reported the study using the median, the minimum and maximum values, and/or the first and third quartiles. Hence, in order to combine results, one may have to estimate the sample mean and standard deviation for such trials. In this paper, we propose to improve the existing literature in several directions. First, we show that the sample standard deviation estimation in Hozo et al.'s method (BMC Med Res Methodol 5:13, 2005) has some serious limitations and is always less satisfactory in practice. Inspired by this, we propose a new estimation method by incorporating the sample size. Second, we systematically study the sample mean and standard deviation estimation problem under several other interesting settings where the interquartile range is also available for the trials. We demonstrate the performance of the proposed methods through simulation studies for the three frequently encountered scenarios, respectively. For the first two scenarios, our method greatly improves existing methods and provides a nearly unbiased estimate of the true sample standard deviation for normal data and a slightly biased estimate for skewed data. For the third scenario, our method still performs very well for both normal data and skewed data. Furthermore, we compare the estimators of the sample mean and standard deviation under all three scenarios and present some suggestions on which scenario is preferred in real-world applications. In this paper, we discuss different approximation methods in the estimation of the sample mean and standard deviation and propose some new estimation methods to improve the existing literature. We conclude our work with a summary table (an Excel spread sheet including all formulas) that serves as a comprehensive guidance for performing meta-analysis in different situations.
Flexner 3.0—Democratization of Medical Knowledge for the 21st Century
Krupinski, Elizabeth A.; Weinstein, John B.; Graham, Anna R.; Barker, Gail P.; Erps, Kristine A.; Holtrust, Angelette L.; Holcomb, Michael J.
2016-01-01
A medical school general pathology course has been reformatted into a K-12 general pathology course. This new course has been implemented at a series of 7 to 12 grade levels and the student outcomes compared. Typically, topics covered mirrored those in a medical school general pathology course serving as an introduction to the mechanisms of diseases. Assessment of student performance was based on their score on a multiple-choice final examination modeled after an examination given to medical students. Two Tucson area schools, in a charter school network, participated in the study. Statistical analysis of examination performances showed that there were no significant differences as a function of school (F = 0.258, P = .6128), with students at school A having an average test scores of 87.03 (standard deviation = 8.99) and school B 86.00 (standard deviation = 8.18; F = 0.258, P = .6128). Analysis of variance was also conducted on the test scores as a function of gender and class grade. There were no significant differences as a function of gender (F = 0.608, P = .4382), with females having an average score of 87.18 (standard deviation = 7.24) and males 85.61 (standard deviation = 9.85). There were also no significant differences as a function of grade level (F = 0.627, P = .6003), with 7th graders having an average of 85.10 (standard deviation = 8.90), 8th graders 86.00 (standard deviation = 9.95), 9th graders 89.67 (standard deviation = 5.52), and 12th graders 86.90 (standard deviation = 7.52). The results demonstrated that middle and upper school students performed equally well in K-12 general pathology. Student course evaluations showed that the course met the student’s expectations. One class voted K-12 general pathology their “elective course-of-the-year.” PMID:28725762
Estimation of the neural drive to the muscle from surface electromyograms
NASA Astrophysics Data System (ADS)
Hofmann, David
Muscle force is highly correlated with the standard deviation of the surface electromyogram (sEMG) produced by the active muscle. Correctly estimating this quantity of non-stationary sEMG and understanding its relation to neural drive and muscle force is of paramount importance. The single constituents of the sEMG are called motor unit action potentials whose biphasic amplitude can interfere (named amplitude cancellation), potentially affecting the standard deviation (Keenan etal. 2005). However, when certain conditions are met the Campbell-Hardy theorem suggests that amplitude cancellation does not affect the standard deviation. By simulation of the sEMG, we verify the applicability of this theorem to myoelectric signals and investigate deviations from its conditions to obtain a more realistic setting. We find no difference in estimated standard deviation with and without interference, standing in stark contrast to previous results (Keenan etal. 2008, Farina etal. 2010). Furthermore, since the theorem provides us with the functional relationship between standard deviation and neural drive we conclude that complex methods based on high density electrode arrays and blind source separation might not bear substantial advantages for neural drive estimation (Farina and Holobar 2016). Funded by NIH Grant Number 1 R01 EB022872 and NSF Grant Number 1208126.
Comparison of a novel fixation device with standard suturing methods for spinal cord stimulators.
Bowman, Richard G; Caraway, David; Bentley, Ishmael
2013-01-01
Spinal cord stimulation is a well-established treatment for chronic neuropathic pain of the trunk or limbs. Currently, the standard method of fixation is to affix the leads of the neuromodulation device to soft tissue, fascia or ligament, through the use of manually tying general suture. A novel semiautomated device is proposed that may be advantageous to the current standard. Comparison testing in an excised caprine spine and simulated bench top model was performed. Three tests were performed: 1) perpendicular pull from fascia of caprine spine; 2) axial pull from fascia of caprine spine; and 3) axial pull from Mylar film. Six samples of each configuration were tested for each scenario. Standard 2-0 Ethibond was compared with a novel semiautomated device (Anulex fiXate). Upon completion of testing statistical analysis was performed for each scenario. For perpendicular pull in the caprine spine, the failure load for standard suture was 8.95 lbs with a standard deviation of 1.39 whereas for fiXate the load was 15.93 lbs with a standard deviation of 2.09. For axial pull in the caprine spine, the failure load for standard suture was 6.79 lbs with a standard deviation of 1.55 whereas for fiXate the load was 12.31 lbs with a standard deviation of 4.26. For axial pull in Mylar film, the failure load for standard suture was 10.87 lbs with a standard deviation of 1.56 whereas for fiXate the load was 19.54 lbs with a standard deviation of 2.24. These data suggest a novel semiautomated device offers a method of fixation that may be utilized in lieu of standard suturing methods as a means of securing neuromodulation devices. Data suggest the novel semiautomated device in fact may provide a more secure fixation than standard suturing methods. © 2012 International Neuromodulation Society.
Computer Programs for the Semantic Differential: Further Modifications.
ERIC Educational Resources Information Center
Lawson, Edwin D.; And Others
The original nine programs for semantic differential analysis have been condensed into three programs which have been further refined and augmented. They yield: (1) means, standard deviations, and standard errors for each subscale on each concept; (2) Evaluation, Potency, and Activity (EPA) means, standard deviations, and standard errors; (3)…
Comparison of direct numerical simulation databases of turbulent channel flow at Reτ = 180
NASA Astrophysics Data System (ADS)
Vreman, A. W.; Kuerten, J. G. M.
2014-01-01
Direct numerical simulation (DNS) databases are compared to assess the accuracy and reproducibility of standard and non-standard turbulence statistics of incompressible plane channel flow at Reτ = 180. Two fundamentally different DNS codes are shown to produce maximum relative deviations below 0.2% for the mean flow, below 1% for the root-mean-square velocity and pressure fluctuations, and below 2% for the three components of the turbulent dissipation. Relatively fine grids and long statistical averaging times are required. An analysis of dissipation spectra demonstrates that the enhanced resolution is necessary for an accurate representation of the smallest physical scales in the turbulent dissipation. The results are related to the physics of turbulent channel flow in several ways. First, the reproducibility supports the hitherto unproven theoretical hypothesis that the statistically stationary state of turbulent channel flow is unique. Second, the peaks of dissipation spectra provide information on length scales of the small-scale turbulence. Third, the computed means and fluctuations of the convective, pressure, and viscous terms in the momentum equation show the importance of the different forces in the momentum equation relative to each other. The Galilean transformation that leads to minimum peak fluctuation of the convective term is determined. Fourth, an analysis of higher-order statistics is performed. The skewness of the longitudinal derivative of the streamwise velocity is stronger than expected (-1.5 at y+ = 30). This skewness and also the strong near-wall intermittency of the normal velocity are related to coherent structures.
Analyses of a 426-Day Record of Seafloor Gravity and Pressure Time Series in the North Sea
NASA Astrophysics Data System (ADS)
Rosat, S.; Escot, B.; Hinderer, J.; Boy, J.-P.
2017-04-01
Continuous gravity observations of ocean and solid tides are usually done with land-based gravimeters. In this study, we analyze a 426-day record of time-varying gravity acquired by an ocean-bottom Scintrex spring gravimeter between August 2005 and November 2006 at the Troll A site located in the North Sea at a depth of 303 m. Sea-bottom pressure changes were also recorded in parallel with a Paroscientific quartz pressure sensor. From these data, we show a comparison of the noise level of the seafloor gravimeter with respect to two standard land-based relative gravimeters: a Scintrex CG5 and a GWR Superconducting Gravimeter that were recording at the J9 gravimetric observatory of Strasbourg (France). We also compare the analyzed gravity records with the predicted solid and oceanic tides. The oceanic tides recorded by the seafloor barometer are also analyzed and compared to the predicted ones using FES2014b ocean model. Observed diurnal and semi-diurnal components are in good agreement with FES2014b predictions. Smallest constituents reflect some differences that may be attributed to non-linearity occurring at the Troll A site. Using the barotropic TUGO-m dynamic model of sea-level response to ECMWF atmospheric pressure and winds forcing, we show a good agreement with the detided ocean-bottom pressure residuals. About 4 hPa of standard deviation of remaining sea-bottom pressure are, however, not explained by the TUGO-m dynamic model.
Determining a one-tailed upper limit for future sample relative reproducibility standard deviations.
McClure, Foster D; Lee, Jung K
2006-01-01
A formula was developed to determine a one-tailed 100p% upper limit for future sample percent relative reproducibility standard deviations (RSD(R),%= 100s(R)/y), where S(R) is the sample reproducibility standard deviation, which is the square root of a linear combination of the sample repeatability variance (s(r)2) plus the sample laboratory-to-laboratory variance (s(L)2), i.e., S(R) = s(L)2, and y is the sample mean. The future RSD(R),% is expected to arise from a population of potential RSD(R),% values whose true mean is zeta(R),% = 100sigmaR, where sigmaR and mu are the population reproducibility standard deviation and mean, respectively.
Rasmussen, Helle Mätzke; Nielsen, Dennis Brandborg; Pedersen, Niels Wisbech; Overgaard, Søren; Holsgaard-Larsen, Anders
2015-07-01
The Gait Deviation Index (GDI) and Gait Profile Score (GPS) are the most used summary measures of gait in children with cerebral palsy (CP). However, the reliability and agreement of these indices have not been investigated, limiting their clinimetric quality for research and clinical practice. The aim of this study was to investigate the intra-rater reliability and agreement of summary measures of gait (GDI; GPS; and the Gait Variable Score (GVS) derived from the GPS). The intra-rater reliability and agreement were investigated across two repeated sessions in 18 children aged 5-12 years diagnosed with spastic CP. No systematic bias was observed between the sessions and no heteroscedasticity was observed in Bland-Altman plots. For the GDI and GPS, excellent reliability with intraclass correlation coefficient (ICC) values of 0.8-0.9 was found, while the GVS was found to have fair to good reliability with ICCs of 0.4-0.7. The agreement for the GDI and the logarithmically transformed GPS, in terms of the standard error of measurement as a percentage of the grand mean (SEM%) varied from 4.1 to 6.7%, whilst the smallest detectable change in percent (SDC%) ranged from 11.3 to 18.5%. For the logarithmically transformed GVS, we found a fair to large variation in SEM% from 7 to 29% and in SDC% from 18 to 81%. The GDI and GPS demonstrated excellent reliability and acceptable agreement proving that they can both be used in research and clinical practice. However, the observed large variability for some of the GVS requires cautious consideration when selecting outcome measures. Copyright © 2015 Elsevier B.V. All rights reserved.
Peltonen, Leena
2018-06-16
The number of poorly soluble drug candidates is increasing, and this is also seen in the research interest towards drug nanoparticles and (nano-)cocrystals; improved solubility is the most important application of these nanosystems. In order to confirm the functionality of these nanoparticles throughout their lifecycle, repeatability of the formulation processes, functional performance of the formed systems in pre-determined way and system stability, a thorough physicochemical understanding with the aid of necessary analytical techniques is needed. Even very minor deviations in for example particle size or size deviation in nanoscale can alter the product bioavailability, and the effect is even more dramatic with the smallest particle size fractions. Also, small particle size sets special requirements for the analytical techniques. In this review most important physicochemical properties of drug nanocrystals and nano-cocrystals are presented, suitable analytical techniques, their pros and cons, are described with the extra input on practical point of view. Copyright © 2018. Published by Elsevier B.V.
Packing Fraction of a Two-dimensional Eden Model with Random-Sized Particles
NASA Astrophysics Data System (ADS)
Kobayashi, Naoki; Yamazaki, Hiroshi
2018-01-01
We have performed a numerical simulation of a two-dimensional Eden model with random-size particles. In the present model, the particle radii are generated from a Gaussian distribution with mean μ and standard deviation σ. First, we have examined the bulk packing fraction for the Eden cluster and investigated the effects of the standard deviation and the total number of particles NT. We show that the bulk packing fraction depends on the number of particles and the standard deviation. In particular, for the dependence on the standard deviation, we have determined the asymptotic value of the bulk packing fraction in the limit of the dimensionless standard deviation. This value is larger than the packing fraction obtained in a previous study of the Eden model with uniform-size particles. Secondly, we have investigated the packing fraction of the entire Eden cluster including the effect of the interface fluctuation. We find that the entire packing fraction depends on the number of particles while it is independent of the standard deviation, in contrast to the bulk packing fraction. In a similar way to the bulk packing fraction, we have obtained the asymptotic value of the entire packing fraction in the limit NT → ∞. The obtained value of the entire packing fraction is smaller than that of the bulk value. This fact suggests that the interface fluctuation of the Eden cluster influences the packing fraction.
Complexities of follicle deviation during selection of a dominant follicle in Bos taurus heifers.
Ginther, O J; Baldrighi, J M; Siddiqui, M A R; Araujo, E R
2016-11-01
Follicle deviation during a follicular wave is a continuation in growth rate of the dominant follicle (F1) and decreased growth rate of the largest subordinate follicle (F2). The reliability of using an F1 of 8.5 mm to represent the beginning of expected deviation for experimental purposes during waves 1 and 2 (n = 26 per wave) was studied daily in heifers. Each wave was subgrouped as follows: standard subgroup (F1 larger than F2 for 2 days preceding deviation and F2 > 7.0 mm on the day of deviation), undersized subgroup (F2 did not attain 7.0 mm by the day of deviation), and switched subgroup (F2 larger than F1 at least once on the 2 days before or on the day of deviation). For each wave, mean differences in diameter between F1 and F2 changed abruptly at expected deviation in the standard subgroup but began 1 day before expected deviation in the undersized and switched subgroups. Concentrations of FSH in the wave-stimulating FSH surge and an increase in LH centered on expected deviation did not differ among subgroups. Results for each wave indicated that (1) expected deviation (F1, 8.5 mm) was a reliable representation of actual deviation in the standard subgroup but not in the undersized and switched subgroups; (2) concentrations of the gonadotropins normalized to expected deviation were similar among the three subgroups, indicating that the day of deviation was related to diameter of F1 and not F2; and (3) defining an expected day of deviation for experimental use should consider both diameter of F1 and the characteristics of deviation. Copyright © 2016 Elsevier Inc. All rights reserved.
40 CFR 90.708 - Cumulative Sum (CumSum) procedure.
Code of Federal Regulations, 2010 CFR
2010-07-01
... is 5.0×σ, and is a function of the standard deviation, σ. σ=is the sample standard deviation and is... individual engine. FEL=Family Emission Limit (the standard if no FEL). F=.25×σ. (2) After each test pursuant...
2015-01-01
The goal of this study was to analyse perceptually and acoustically the voices of patients with Unilateral Vocal Fold Paralysis (UVFP) and compare them to the voices of normal subjects. These voices were analysed perceptually with the GRBAS scale and acoustically using the following parameters: mean fundamental frequency (F0), standard-deviation of F0, jitter (ppq5), shimmer (apq11), mean harmonics-to-noise ratio (HNR), mean first (F1) and second (F2) formants frequency, and standard-deviation of F1 and F2 frequencies. Statistically significant differences were found in all of the perceptual parameters. Also the jitter, shimmer, HNR, standard-deviation of F0, and standard-deviation of the frequency of F2 were statistically different between groups, for both genders. In the male data differences were also found in F1 and F2 frequencies values and in the standard-deviation of the frequency of F1. This study allowed the documentation of the alterations resulting from UVFP and addressed the exploration of parameters with limited information for this pathology. PMID:26557690
NASA Astrophysics Data System (ADS)
Krasnenko, N. P.; Kapegesheva, O. F.; Shamanaeva, L. G.
2017-11-01
Spatiotemporal dynamics of the standard deviations of three wind velocity components measured with a mini-sodar in the atmospheric boundary layer is analyzed. During the day on September 16 and at night on September 12 values of the standard deviation changed for the x- and y-components from 0.5 to 4 m/s, and for the z-component from 0.2 to 1.2 m/s. An analysis of the vertical profiles of the standard deviations of three wind velocity components for a 6-day measurement period has shown that the increase of σx and σy with altitude is well described by a power law dependence with exponent changing from 0.22 to 1.3 depending on the time of day, and σz depends linearly on the altitude. The approximation constants have been found and their errors have been estimated. The established physical regularities and the approximation constants allow the spatiotemporal dynamics of the standard deviation of three wind velocity components in the atmospheric boundary layer to be described and can be recommended for application in ABL models.
A proof for Rhiel's range estimator of the coefficient of variation for skewed distributions.
Rhiel, G Steven
2007-02-01
In this research study is proof that the coefficient of variation (CV(high-low)) calculated from the highest and lowest values in a set of data is applicable to specific skewed distributions with varying means and standard deviations. Earlier Rhiel provided values for d(n), the standardized mean range, and a(n), an adjustment for bias in the range estimator of micro. These values are used in estimating the coefficient of variation from the range for skewed distributions. The d(n) and an values were specified for specific skewed distributions with a fixed mean and standard deviation. In this proof it is shown that the d(n) and an values are applicable for the specific skewed distributions when the mean and standard deviation can take on differing values. This will give the researcher confidence in using this statistic for skewed distributions regardless of the mean and standard deviation.
Interpretation of small-angle diffraction experiments on opal-like photonic crystals
NASA Astrophysics Data System (ADS)
Marlow, F.; Muldarisnur, M.; Sharifi, P.; Zabel, H.
2011-08-01
Comprehensive structural information on artificial opals involving the deviations from the strongly dominating face-centered cubic structure is still missing. Recent structure investigations with neutrons and synchrotron sources have shown a high degree of order but also a number of unexpected scattering features. Here, we point out that the exclusion of the allowed 002-type diffraction peaks by a small atomic form factor is not obvious and that surface scattering has to be included as a possible source for the diffraction peaks. Our neutron diffraction data indicate that surface scattering is the main reason for the smallest-angle peaks in the diffraction patterns.
Random errors in interferometry with the least-squares method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang Qi
2011-01-20
This investigation analyzes random errors in interferometric surface profilers using the least-squares method when random noises are present. Two types of random noise are considered here: intensity noise and position noise. Two formulas have been derived for estimating the standard deviations of the surface height measurements: one is for estimating the standard deviation when only intensity noise is present, and the other is for estimating the standard deviation when only position noise is present. Measurements on simulated noisy interferometric data have been performed, and standard deviations of the simulated measurements have been compared with those theoretically derived. The relationships havemore » also been discussed between random error and the wavelength of the light source and between random error and the amplitude of the interference fringe.« less
Mattos, Jose L; Schlosser, Rodney J; Mace, Jess C; Smith, Timothy L; Soler, Zachary M
2018-05-02
Olfactory-specific quality of life (QOL) can be measured using the Questionnaire of Olfactory Disorders Negative Statements (QOD-NS). Changes in the QOD-NS after treatment can be difficult to interpret since there is no standardized definition of clinically meaningful improvement. Patients with chronic rhinosinusitis (CRS) completed the QOD-NS. Four distribution-based methods were used to calculate the minimal clinically important difference (MCID): (1) one-half standard deviation (SD); (2) standard error of the mean (SEM); (3) Cohen's effect size (d) of the smallest unit of change; and (4) minimal detectable change (MDC). We also averaged all 4 of the scores together. Finally, the likelihood of achieving a MCID after sinus surgery using these methods, as well as average QOD-NS scores, was stratified by normal vs abnormal baseline QOD-NS scores. Outcomes were examined on 128 patients. The mean ± SD improvement in QOD-NS score after surgery was 4.3 ± 11.0 for the entire cohort and 9.6 ± 12.9 for those with abnormal baseline scores (p < 0.001). The MCID values using the different techniques were: (1) SD = 6.5; (2) SEM = 3.1; (3) d = 2.6; and (4) MDC = 8.6. The MCID score was 5.2 on average. For the total cohort analysis, the likelihood of reporting a MCID ranged from 26% to 51%, and 49% to 70% for patients reporting preoperative abnormal olfaction. Distribution-based MCID values of the QOD-NS range between 2.6 and 8.6 points, with an average of 5.2. When stratified by preoperative QOD-NS scores the majority of patients reporting abnormal preoperative QOD-NS scores achieved a MCID. © 2018 ARS-AAOA, LLC.
N2/O2/H2 Dual-Pump Cars: Validation Experiments
NASA Technical Reports Server (NTRS)
OByrne, S.; Danehy, P. M.; Cutler, A. D.
2003-01-01
The dual-pump coherent anti-Stokes Raman spectroscopy (CARS) method is used to measure temperature and the relative species densities of N2, O2 and H2 in two experiments. Average values and root-mean-square (RMS) deviations are determined. Mean temperature measurements in a furnace containing air between 300 and 1800 K agreed with thermocouple measurements within 26 K on average, while mean mole fractions agree to within 1.6 % of the expected value. The temperature measurement standard deviation averaged 64 K while the standard deviation of the species mole fractions averaged 7.8% for O2 and 3.8% for N2, based on 200 single-shot measurements. Preliminary measurements have also been performed in a flat-flame burner for fuel-lean and fuel-rich flames. Temperature standard deviations of 77 K were measured, and the ratios of H2 to N2 and O2 to N2 respectively had standard deviations from the mean value of 12.3% and 10% of the measured ratio.
Trujillo, Logan T.; Stanfield, Candice T.; Vela, Ruben D.
2017-01-01
Converging evidence suggests that human cognition and behavior emerge from functional brain networks interacting on local and global scales. We investigated two information-theoretic measures of functional brain segregation and integration—interaction complexity CI(X), and integration I(X)—as applied to electroencephalographic (EEG) signals and how these measures are affected by choice of EEG reference. CI(X) is a statistical measure of the system entropy accounted for by interactions among its elements, whereas I(X) indexes the overall deviation from statistical independence of the individual elements of a system. We recorded 72 channels of scalp EEG from human participants who sat in a wakeful resting state (interleaved counterbalanced eyes-open and eyes-closed blocks). CI(X) and I(X) of the EEG signals were computed using four different EEG references: linked-mastoids (LM) reference, average (AVG) reference, a Laplacian (LAP) “reference-free” transformation, and an infinity (INF) reference estimated via the Reference Electrode Standardization Technique (REST). Fourier-based power spectral density (PSD), a standard measure of resting state activity, was computed for comparison and as a check of data integrity and quality. We also performed dipole source modeling in order to assess the accuracy of neural source CI(X) and I(X) estimates obtained from scalp-level EEG signals. CI(X) was largest for the LAP transformation, smallest for the LM reference, and at intermediate values for the AVG and INF references. I(X) was smallest for the LAP transformation, largest for the LM reference, and at intermediate values for the AVG and INF references. Furthermore, across all references, CI(X) and I(X) reliably distinguished between resting-state conditions (larger values for eyes-open vs. eyes-closed). These findings occurred in the context of the overall expected pattern of resting state PSD. Dipole modeling showed that simulated scalp EEG-level CI(X) and I(X) reflected changes in underlying neural source dependencies, but only for higher levels of integration and with highest accuracy for the LAP transformation. Our observations suggest that the Laplacian-transformation should be preferred for the computation of scalp-level CI(X) and I(X) due to its positive impact on EEG signal quality and statistics, reduction of volume-conduction, and the higher accuracy this provides when estimating scalp-level EEG complexity and integration. PMID:28790884
Comparative study of navigated versus freehand osteochondral graft transplantation of the knee.
Koulalis, Dimitrios; Di Benedetto, Paolo; Citak, Mustafa; O'Loughlin, Padhraig; Pearle, Andrew D; Kendoff, Daniel O
2009-04-01
Osteochondral lesions are a common sports-related injury for which osteochondral grafting, including mosaicplasty, is an established treatment. Computer navigation has been gaining popularity in orthopaedic surgery to improve accuracy and precision. Navigation improves angle and depth matching during harvest and placement of osteochondral grafts compared with conventional freehand open technique. Controlled laboratory study. Three cadaveric knees were used. Reference markers were attached to the femur, tibia, and donor/recipient site guides. Fifteen osteochondral grafts were harvested and inserted into recipient sites with computer navigation, and 15 similar grafts were inserted freehand. The angles of graft removal and placement as well as surface congruity (graft depth) were calculated for each surgical group. The mean harvesting angle at the donor site using navigation was 4 degrees (standard deviation, 2.3 degrees ; range, 1 degrees -9 degrees ) versus 12 degrees (standard deviation, 5.5 degrees ; range, 5 degrees -24 degrees ) using freehand technique (P < .0001). The recipient plug removal angle using the navigated technique was 3.3 degrees (standard deviation, 2.1 degrees ; range, 0 degrees -9 degrees ) versus 10.7 degrees (standard deviation, 4.9 degrees ; range, 2 degrees -17 degrees ) in freehand (P < .0001). The mean navigated recipient plug placement angle was 3.6 degrees (standard deviation, 2.0 degrees ; range, 1 degrees -9 degrees ) versus 10.6 degrees (standard deviation, 4.4 degrees ; range, 3 degrees -17 degrees ) with freehand technique (P = .0001). The mean height of plug protrusion under navigation was 0.3 mm (standard deviation, 0.2 mm; range, 0-0.6 mm) versus 0.5 mm (standard deviation, 0.3 mm; range, 0.2-1.1 mm) using a freehand technique (P = .0034). Significantly greater accuracy and precision were observed in harvesting and placement of the osteochondral grafts in the navigated procedures. Clinical studies are needed to establish a benefit in vivo. Improvement in the osteochondral harvest and placement is desirable to optimize clinical outcomes. Navigation shows great potential to improve both harvest and placement precision and accuracy, thus optimizing ultimate surface congruity.
Kennedy, Matthew Joel; Arcelus, Amaya; Guitard, Paulette; Goubran, R A; Sveistrup, Heidi
2015-01-01
Multiple toilet grab-bar configurations are required by people with a diverse spectrum of disability. The study purpose was to determine toilet grab-bar preference of healthy seniors, seniors with a hip replacement, and seniors post-stroke, and to determine the effect of each configuration on centre of pressure (COP) displacement during toilet transfers. 14 healthy seniors, 7 ambulatory seniors with a hip replacement, and 8 ambulatory seniors post-stroke participated in the study. Toilet transfers were performed with no bars (NB), commode (C), two vertical bars (2VB), one vertical bar (1VB), a horizontal bar (H), two swing-away bars (S) and a diagonal bar (D). COP was measured using pressure sensitive floor mats. Participants rated the safety, ease of use, helpfulness, comfort and preference for instalment. 2VB was most preferred and had the smallest COP deviation. Least preferred was H and NB. C caused largest COP displacement but had favourable ratings. The preference and safety of the 2VB should be considered in the design of accessible toilets and in accessibility construction guidelines. However these results need to be verified in non-ambulatory populations. C is frequently prescribed, but generates large COP deviation, suggesting it may present an increased risk of falls.
Matrix Summaries Improve Research Reports: Secondary Analyses Using Published Literature
ERIC Educational Resources Information Center
Zientek, Linda Reichwein; Thompson, Bruce
2009-01-01
Correlation matrices and standard deviations are the building blocks of many of the commonly conducted analyses in published research, and AERA and APA reporting standards recommend their inclusion when reporting research results. The authors argue that the inclusion of correlation/covariance matrices, standard deviations, and means can enhance…
30 CFR 74.8 - Measurement, accuracy, and reliability requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... concentration, as defined by the relative standard deviation of the distribution of measurements. The relative standard deviation shall be less than 0.1275 without bias for both full-shift measurements of 8 hours or... Standards, Regulations, and Variances, 1100 Wilson Boulevard, Room 2350, Arlington, Virginia 22209-3939...
SU-F-J-21: Clinical Evaluation of Surface Scanning Systems in Different Treatment Locations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moser, T; Karger, C; Stefanowicz, S
Purpose: To reduce imaging dose in fractionated IGRT, the ability of optical surface imaging systems (OSIS) to detect setup errors was tested. Therefore, clinical studies to evaluate for different treatment locations setup corrections derived by OSIS in comparison with x-ray image guidance in fractionated radiation therapy was performed. Methods: The setup correction accuracy of an OSIS system (AlignRT, VisionRT, London, UK) will be analysed for the 4 tumour locations Pelvis, Upper Abdomen, Thorax and Breast, 20 patients for each location in comparison to a different system (Sentinel, C-RAD, SE). For each patient, the setup corrections of the cone-beam computed tomographymore » (CBCT) of an Elekta Versa HD linear accelerator (Elekta, Crawley, UK) is considered as gold-standard and then compared with those of the OSIS for the first ten fractions retrospectively. There were no clinical decisions made based on the surrogate system. For the OSIS, the reference surface is highly important as it represents the actual ground truth. It can be obtained either with the system itself or the surface structure delineated in the planning CT can be imported via DICOM interface. In this paper, the first results for the treatment region thorax are presented. The reference image modalities were compared. Results: Table 1 displays the difference between the setup corrections obtained with OSIS and CBCT in lateral (LAT), longitudinal (LNG) and vertical (VRT) direction for the DICOM reference image. While the median deviations are within a few millimeters, some outliers showed large deviations. Generally, the mean deviation as well as the spread was smallest in lateral and largest in vertical direction. Conclusion: Although the system allows fast, simple and non-invasive determination of setup corrections, it should be evaluated treatment region dependant. Therefore, the study is ongoing. The application of OSIS may help to reduce the imaging dose for the patient. We gratefully acknowledge the support by our colleagues from the Radiological University Clinic Heidelberg, where the study was performed. This work was funded by the Federal Ministry of Education and Research (BMBF) Germany, grant number 01IB13001B.« less
The effects of auditory stimulation with music on heart rate variability in healthy women.
Roque, Adriano L; Valenti, Vitor E; Guida, Heraldo L; Campos, Mônica F; Knap, André; Vanderlei, Luiz Carlos M; Ferreira, Lucas L; Ferreira, Celso; Abreu, Luiz Carlos de
2013-07-01
There are no data in the literature with regard to the acute effects of different styles of music on the geometric indices of heart rate variability. In this study, we evaluated the acute effects of relaxant baroque and excitatory heavy metal music on the geometric indices of heart rate variability in women. We conducted this study in 21 healthy women ranging in age from 18 to 35 years. We excluded persons with previous experience with musical instruments and persons who had an affinity for the song styles. We evaluated two groups: Group 1 (n = 21), who were exposed to relaxant classical baroque musical and excitatory heavy metal auditory stimulation; and Group 2 (n = 19), who were exposed to both styles of music and white noise auditory stimulation. Using earphones, the volunteers were exposed to baroque or heavy metal music for five minutes. After the first music exposure to baroque or heavy metal music, they remained at rest for five minutes; subsequently, they were re-exposed to the opposite music (70-80 dB). A different group of women were exposed to the same music styles plus white noise auditory stimulation (90 dB). The sequence of the songs was randomized for each individual. We analyzed the following indices: triangular index, triangular interpolation of RR intervals and Poincaré plot (standard deviation of instantaneous beat-by-beat variability, standard deviation of the long-term RR interval, standard deviation of instantaneous beat-by-beat variability and standard deviation of the long-term RR interval ratio), low frequency, high frequency, low frequency/high frequency ratio, standard deviation of all the normal RR intervals, root-mean square of differences between the adjacent normal RR intervals and the percentage of adjacent RR intervals with a difference of duration greater than 50 ms. Heart rate variability was recorded at rest for 10 minutes. The triangular index and the standard deviation of the long-term RR interval indices were reduced during exposure to both music styles in the first group and tended to decrease in the second group whereas the white noise exposure decreased the high frequency index. We observed no changes regarding the triangular interpolation of RR intervals, standard deviation of instantaneous beat-by-beat variability and standard deviation of instantaneous beat-by-beat variability/standard deviation in the long-term RR interval ratio. We suggest that relaxant baroque and excitatory heavy metal music slightly decrease global heart rate variability because of the equivalent sound level.
The effects of auditory stimulation with music on heart rate variability in healthy women
Roque, Adriano L.; Valenti, Vitor E.; Guida, Heraldo L.; Campos, Mônica F.; Knap, André; Vanderlei, Luiz Carlos M.; Ferreira, Lucas L.; Ferreira, Celso; de Abreu, Luiz Carlos
2013-01-01
OBJECTIVES: There are no data in the literature with regard to the acute effects of different styles of music on the geometric indices of heart rate variability. In this study, we evaluated the acute effects of relaxant baroque and excitatory heavy metal music on the geometric indices of heart rate variability in women. METHODS: We conducted this study in 21 healthy women ranging in age from 18 to 35 years. We excluded persons with previous experience with musical instruments and persons who had an affinity for the song styles. We evaluated two groups: Group 1 (n = 21), who were exposed to relaxant classical baroque musical and excitatory heavy metal auditory stimulation; and Group 2 (n = 19), who were exposed to both styles of music and white noise auditory stimulation. Using earphones, the volunteers were exposed to baroque or heavy metal music for five minutes. After the first music exposure to baroque or heavy metal music, they remained at rest for five minutes; subsequently, they were re-exposed to the opposite music (70-80 dB). A different group of women were exposed to the same music styles plus white noise auditory stimulation (90 dB). The sequence of the songs was randomized for each individual. We analyzed the following indices: triangular index, triangular interpolation of RR intervals and Poincaré plot (standard deviation of instantaneous beat-by-beat variability, standard deviation of the long-term RR interval, standard deviation of instantaneous beat-by-beat variability and standard deviation of the long-term RR interval ratio), low frequency, high frequency, low frequency/high frequency ratio, standard deviation of all the normal RR intervals, root-mean square of differences between the adjacent normal RR intervals and the percentage of adjacent RR intervals with a difference of duration greater than 50 ms. Heart rate variability was recorded at rest for 10 minutes. RESULTS: The triangular index and the standard deviation of the long-term RR interval indices were reduced during exposure to both music styles in the first group and tended to decrease in the second group whereas the white noise exposure decreased the high frequency index. We observed no changes regarding the triangular interpolation of RR intervals, standard deviation of instantaneous beat-by-beat variability and standard deviation of instantaneous beat-by-beat variability/standard deviation in the long-term RR interval ratio. CONCLUSION: We suggest that relaxant baroque and excitatory heavy metal music slightly decrease global heart rate variability because of the equivalent sound level. PMID:23917660
USL/DBMS NASA/PC R and D project C programming standards
NASA Technical Reports Server (NTRS)
Dominick, Wayne D. (Editor); Moreau, Dennis R.
1984-01-01
A set of programming standards intended to promote reliability, readability, and portability of C programs written for PC research and development projects is established. These standards must be adhered to except where reasons for deviation are clearly identified and approved by the PC team. Any approved deviation from these standards must also be clearly documented in the pertinent source code.
Are tidal volume measurements in neonatal pressure-controlled ventilation accurate?
Chow, Lily C; Vanderhal, Andre; Raber, Jorge; Sola, Augusto
2002-09-01
Bedside pulmonary mechanics monitors (PMM) have become useful in ventilatory management in neonates. These monitors are used more frequently due to recent improvements in data-processing capabilities. PMM devices are often part of the ventilator or are separate units. The accuracy and reliability of these systems have not been carefully evaluated. We compared a single ventilatory parameter, tidal volume (V(t)), as measured by several systems. We looked at two freestanding PMMs: the Ventrak Respiratory Monitoring System (Novametrix, Wallingford, CT) and the Bicore CP-100 Neonatal Pulmonary Monitor (Allied Health Care Products, Riverside, CA), and three ventilators with built-in PMM: the VIP Bird Ventilator (Bird Products Corp., Palm Springs, CA), Siemens Servo 300A (Siemens-Elema AB, Solna, Sweden), and Drager Babylog 8000 (Drager, Inc., Chantilly, VA). A calibrated syringe (Hans Rudolph, Inc., Kansas City, MO) was used to deliver tidal volumes of 4, 10, and 20 mL to each ventilator system coupled with a freestanding PMM. After achieving steady state, six consecutive V(t) readings were taken simultaneously from the freestanding PMM and each ventilator. In a second portion of the bench study, we used pressure-control ventilation and measured exhaled tidal volume (V(te)) while ventilating a Bear Test Lung with the same three ventilators. We adjusted peak inspiratory pressure (PIP) under controlled conditions to achieve the three different targeted tidal volumes on the paired freestanding PMM. Again, six V(te) measurements were recorded for each tidal volume. Means and standard deviations were calculated.The percentage difference in measurement of V(t) delivered by calibrated syringe varied greatly, with the greatest discrepancy seen in the smallest tidal volumes, by up to 28%. In pressure control mode, V(te) as measured by the Siemens was significantly overestimated by 20-95%, with the biggest discrepancy at the smallest V(te), particularly when paired with the Bicore PMM. V(te), as measured by the VIP Bird and Drager paired with the Ventrak PMM, had a tendency to underestimate V(t) by up to 25% at the smallest V(te). However, when paired with the Bicore PMM, these same two ventilators read over target by up to 18%. Under controlled laboratory conditions, we demonstrated that true delivered V(te), as measured by the three ventilators and two freestanding PMM, differed markedly. In general, decreasing dynamic compliance of the tubing was not associated with greater inaccuracy in V(te) measurements. Copyright 2002 Wiley-Liss, Inc.
Ran, Yang; Su, Rongtao; Ma, Pengfei; Wang, Xiaolin; Zhou, Pu; Si, Lei
2016-05-10
We present a new quantitative index of standard deviation to measure the homogeneity of spectral lines in a fiber amplifier system so as to find the relation between the stimulated Brillouin scattering (SBS) threshold and the homogeneity of the corresponding spectral lines. A theoretical model is built and a simulation framework has been established to estimate the SBS threshold when input spectra with different homogeneities are set. In our experiment, by setting the phase modulation voltage to a constant value and the modulation frequency to different values, spectral lines with different homogeneities can be obtained. The experimental results show that the SBS threshold increases negatively with the standard deviation of the modulated spectrum, which is in good agreement with the theoretical results. When the phase modulation voltage is confined to 10 V and the modulation frequency is set to 80 MHz, the standard deviation of the modulated spectrum equals 0.0051, which is the lowest value in our experiment. Thus, at this time, the highest SBS threshold has been achieved. This standard deviation can be a good quantitative index in evaluating the power scaling potential in a fiber amplifier system, which is also a design guideline in suppressing the SBS to a better degree.
A Weighted and Directed Interareal Connectivity Matrix for Macaque Cerebral Cortex
Markov, N. T.; Ercsey-Ravasz, M. M.; Ribeiro Gomes, A. R.; Lamy, C.; Magrou, L.; Vezoli, J.; Misery, P.; Falchier, A.; Quilodran, R.; Gariel, M. A.; Sallet, J.; Gamanut, R.; Huissoud, C.; Clavagnier, S.; Giroud, P.; Sappey-Marinier, D.; Barone, P.; Dehay, C.; Toroczkai, Z.; Knoblauch, K.; Van Essen, D. C.; Kennedy, H.
2014-01-01
Retrograde tracer injections in 29 of the 91 areas of the macaque cerebral cortex revealed 1,615 interareal pathways, a third of which have not previously been reported. A weight index (extrinsic fraction of labeled neurons [FLNe]) was determined for each area-to-area pathway. Newly found projections were weaker on average compared with the known projections; nevertheless, the 2 sets of pathways had extensively overlapping weight distributions. Repeat injections across individuals revealed modest FLNe variability given the range of FLNe values (standard deviation <1 log unit, range 5 log units). The connectivity profile for each area conformed to a lognormal distribution, where a majority of projections are moderate or weak in strength. In the G29 × 29 interareal subgraph, two-thirds of the connections that can exist do exist. Analysis of the smallest set of areas that collects links from all 91 nodes of the G29 × 91 subgraph (dominating set analysis) confirms the dense (66%) structure of the cortical matrix. The G29 × 29 subgraph suggests an unexpectedly high incidence of unidirectional links. The directed and weighted G29 × 91 connectivity matrix for the macaque will be valuable for comparison with connectivity analyses in other species, including humans. It will also inform future modeling studies that explore the regularities of cortical networks. PMID:23010748
Reljin, Natasa; Reyes, Bersain A.; Chon, Ki H.
2015-01-01
In this paper, we propose the use of blanket fractal dimension (BFD) to estimate the tidal volume from smartphone-acquired tracheal sounds. We collected tracheal sounds with a Samsung Galaxy S4 smartphone, from five (N = 5) healthy volunteers. Each volunteer performed the experiment six times; first to obtain linear and exponential fitting models, and then to fit new data onto the existing models. Thus, the total number of recordings was 30. The estimated volumes were compared to the true values, obtained with a Respitrace system, which was considered as a reference. Since Shannon entropy (SE) is frequently used as a feature in tracheal sound analyses, we estimated the tidal volume from the same sounds by using SE as well. The evaluation of the performed estimation, using BFD and SE methods, was quantified by the normalized root-mean-squared error (NRMSE). The results show that the BFD outperformed the SE (at least twice smaller NRMSE was obtained). The smallest NRMSE error of 15.877% ± 9.246% (mean ± standard deviation) was obtained with the BFD and exponential model. In addition, it was shown that the fitting curves calculated during the first day of experiments could be successfully used for at least the five following days. PMID:25923929
Eikemo, Terje A; Huisman, Martijn; Bambra, Clare; Kunst, Anton E
2008-05-01
The object of this study was to determine whether the magnitude of educational health inequalities varies between European countries with different welfare regimes. The data source is based on the first and second wave of the European Social Survey. The first health indicator describes people's mental and physical health in general, while the second reports cases of any limiting longstanding illness. Educational inequalities in health were measured as the difference in health between people with an average number of years of education and people whose educational years lay one standard deviation below the national average. Moreover, South European welfare regimes had the largest health inequalities, while countries with Bismarckian welfare regimes tended to demonstrate the smallest. Although the other welfare regimes ranked relatively close to each other, the Scandinavian welfare regimes were placed less favourably than the Anglo-Saxon and East European. Thus, this study shows an evident patterning of magnitudes of health inequalities according to features of European welfare regimes. Although the greater distribution of welfare benefits within the Scandinavian countries are likely to have a protective effect for disadvantaged cities in these countries, other factors such as relative deprivation and class-patterned health behaviours might be acting to widen health inequalities.
Reljin, Natasa; Reyes, Bersain A; Chon, Ki H
2015-04-27
In this paper, we propose the use of blanket fractal dimension (BFD) to estimate the tidal volume from smartphone-acquired tracheal sounds. We collected tracheal sounds with a Samsung Galaxy S4 smartphone, from five (N = 5) healthy volunteers. Each volunteer performed the experiment six times; first to obtain linear and exponential fitting models, and then to fit new data onto the existing models. Thus, the total number of recordings was 30. The estimated volumes were compared to the true values, obtained with a Respitrace system, which was considered as a reference. Since Shannon entropy (SE) is frequently used as a feature in tracheal sound analyses, we estimated the tidal volume from the same sounds by using SE as well. The evaluation of the performed estimation, using BFD and SE methods, was quantified by the normalized root-mean-squared error (NRMSE). The results show that the BFD outperformed the SE (at least twice smaller NRMSE was obtained). The smallest NRMSE error of 15.877% ± 9.246% (mean ± standard deviation) was obtained with the BFD and exponential model. In addition, it was shown that the fitting curves calculated during the first day of experiments could be successfully used for at least the five following days.
NetCDF file of the SREF standard deviation of wind speed and direction that was used to inject variability in the FDDA input.variable U_NDG_OLD contains standard deviation of wind speed (m/s)variable V_NDG_OLD contains the standard deviation of wind direction (deg)This dataset is associated with the following publication:Gilliam , R., C. Hogrefe , J. Godowitch, S. Napelenok , R. Mathur , and S.T. Rao. Impact of inherent meteorology uncertainty on air quality model predictions. JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES. American Geophysical Union, Washington, DC, USA, 120(23): 12,259–12,280, (2015).
75 FR 67093 - Iceberg Water Deviating From Identity Standard; Temporary Permit for Market Testing
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-01
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-P-0517] Iceberg Water Deviating From Identity Standard; Temporary Permit for Market Testing AGENCY: Food and Drug... from the requirements of the standards of identity issued under section 401 of the Federal Food, Drug...
78 FR 2273 - Canned Tuna Deviating From Identity Standard; Temporary Permit for Market Testing
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-10
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2012-P-1189] Canned Tuna Deviating From Identity Standard; Temporary Permit for Market Testing AGENCY: Food and Drug... interstate shipment of experimental packs of food varying from the requirements of standards of identity...
Upgraded FAA Airfield Capacity Model. Volume 2. Technical Description of Revisions
1981-02-01
the threshold t k a the time at which departure k is released FIGURE 3-1 TIME AXIS DIAGRAM OF SINGLE RUNWAY OPERATIONS 3-2 J"- SIGMAR the standard...standard deviation of the interarrival time. SIGMAR - the standard deviation of the arrival runway occupancy time. A-5 SINGLE - program subroutine for
Software thresholds alter the bias of actigraphy for monitoring sleep in team-sport athletes.
Fuller, Kate L; Juliff, Laura; Gore, Christopher J; Peiffer, Jeremiah J; Halson, Shona L
2017-08-01
Actical ® actigraphy is commonly used to monitor athlete sleep. The proprietary software, called Actiware ® , processes data with three different sleep-wake thresholds (Low, Medium or High), but there is no standardisation regarding their use. The purpose of this study was to examine validity and bias of the sleep-wake thresholds for processing Actical ® sleep data in team sport athletes. Validation study comparing actigraph against accepted gold standard polysomnography (PSG). Sixty seven nights of sleep were recorded simultaneously with polysomnography and Actical ® devices. Individual night data was compared across five sleep measures for each sleep-wake threshold using Actiware ® software. Accuracy of each sleep-wake threshold compared with PSG was evaluated from mean bias with 95% confidence limits, Pearson moment-product correlation and associated standard error of estimate. The Medium threshold generated the smallest mean bias compared with polysomnography for total sleep time (8.5min), sleep efficiency (1.8%) and wake after sleep onset (-4.1min); whereas the Low threshold had the smallest bias (7.5min) for wake bouts. Bias in sleep onset latency was the same across thresholds (-9.5min). The standard error of the estimate was similar across all thresholds; total sleep time ∼25min, sleep efficiency ∼4.5%, wake after sleep onset ∼21min, and wake bouts ∼8 counts. Sleep parameters measured by the Actical ® device are greatly influenced by the sleep-wake threshold applied. In the present study the Medium threshold produced the smallest bias for most parameters compared with PSG. Given the magnitude of measurement variability, confidence limits should be employed when interpreting changes in sleep parameters. Copyright © 2017 Sports Medicine Australia. All rights reserved.
Reproducibility of 3D kinematics and surface electromyography measurements of mastication.
Remijn, Lianne; Groen, Brenda E; Speyer, Renée; van Limbeek, Jacques; Nijhuis-van der Sanden, Maria W G
2016-03-01
The aim of this study was to determine the measurement reproducibility for a procedure evaluating the mastication process and to estimate the smallest detectable differences of 3D kinematic and surface electromyography (sEMG) variables. Kinematics of mandible movements and sEMG activity of the masticatory muscles were obtained over two sessions with four conditions: two food textures (biscuit and bread) of two sizes (small and large). Twelve healthy adults (mean age 29.1 years) completed the study. The second to the fifth chewing cycle of 5 bites were used for analyses. The reproducibility per outcome variable was calculated with an intraclass correlation coefficient (ICC) and a Bland-Altman analysis was applied to determine the standard error of measurement relative error of measurement and smallest detectable differences of all variables. ICCs ranged from 0.71 to 0.98 for all outcome variables. The outcome variables consisted of four bite and fourteen chewing cycle variables. The relative standard error of measurement of the bite variables was up to 17.3% for 'time-to-swallow', 'time-to-transport' and 'number of chewing cycles', but ranged from 31.5% to 57.0% for 'change of chewing side'. The relative standard error of measurement ranged from 4.1% to 24.7% for chewing cycle variables and was smaller for kinematic variables than sEMG variables. In general, measurements obtained with 3D kinematics and sEMG are reproducible techniques to assess the mastication process. The duration of the chewing cycle and frequency of chewing were the best reproducible measurements. Change of chewing side could not be reproduced. The published measurement error and smallest detectable differences will aid the interpretation of the results of future clinical studies using the same study variables. Copyright © 2015 Elsevier Inc. All rights reserved.
Methods of editing cloud and atmospheric layer affected pixels from satellite data
NASA Technical Reports Server (NTRS)
Nixon, P. R.; Wiegand, C. L.; Richardson, A. J.; Johnson, M. P. (Principal Investigator)
1982-01-01
Subvisible cirrus clouds (SCi) were easily distinguished in mid-infrared (MIR) TIROS-N daytime data from south Texas and northeast Mexico. The MIR (3.55-3.93 micrometer) pixel digital count means of the SCi affected areas were more than 3.5 standard deviations on the cold side of the scene means. (These standard deviations were made free of the effects of unusual instrument error by factoring out the Ch 3 MIR noise on the basis of detailed examination of noisy and noise-free pixels). SCi affected areas in the IR Ch 4 (10.5-11.5 micrometer) appeared cooler than the general scene, but were not as prominent as in Ch 3, being less than 2 standard deviations from the scene mean. Ch 3 and 4 standard deviations and coefficients of variation are not reliable indicators, by themselves, of the presence of SCi because land features can have similar statistical properties.
A Taxonomy of Delivery and Documentation Deviations During Delivery of High-Fidelity Simulations.
McIvor, William R; Banerjee, Arna; Boulet, John R; Bekhuis, Tanja; Tseytlin, Eugene; Torsher, Laurence; DeMaria, Samuel; Rask, John P; Shotwell, Matthew S; Burden, Amanda; Cooper, Jeffrey B; Gaba, David M; Levine, Adam; Park, Christine; Sinz, Elizabeth; Steadman, Randolph H; Weinger, Matthew B
2017-02-01
We developed a taxonomy of simulation delivery and documentation deviations noted during a multicenter, high-fidelity simulation trial that was conducted to assess practicing physicians' performance. Eight simulation centers sought to implement standardized scenarios over 2 years. Rules, guidelines, and detailed scenario scripts were established to facilitate reproducible scenario delivery; however, pilot trials revealed deviations from those rubrics. A taxonomy with hierarchically arranged terms that define a lack of standardization of simulation scenario delivery was then created to aid educators and researchers in assessing and describing their ability to reproducibly conduct simulations. Thirty-six types of delivery or documentation deviations were identified from the scenario scripts and study rules. Using a Delphi technique and open card sorting, simulation experts formulated a taxonomy of high-fidelity simulation execution and documentation deviations. The taxonomy was iteratively refined and then tested by 2 investigators not involved with its development. The taxonomy has 2 main classes, simulation center deviation and participant deviation, which are further subdivided into as many as 6 subclasses. Inter-rater classification agreement using the taxonomy was 74% or greater for each of the 7 levels of its hierarchy. Cohen kappa calculations confirmed substantial agreement beyond that expected by chance. All deviations were classified within the taxonomy. This is a useful taxonomy that standardizes terms for simulation delivery and documentation deviations, facilitates quality assurance in scenario delivery, and enables quantification of the impact of deviations upon simulation-based performance assessment.
Kwon, Deukwoo; Reis, Isildinha M
2015-08-12
When conducting a meta-analysis of a continuous outcome, estimated means and standard deviations from the selected studies are required in order to obtain an overall estimate of the mean effect and its confidence interval. If these quantities are not directly reported in the publications, they must be estimated from other reported summary statistics, such as the median, the minimum, the maximum, and quartiles. We propose a simulation-based estimation approach using the Approximate Bayesian Computation (ABC) technique for estimating mean and standard deviation based on various sets of summary statistics found in published studies. We conduct a simulation study to compare the proposed ABC method with the existing methods of Hozo et al. (2005), Bland (2015), and Wan et al. (2014). In the estimation of the standard deviation, our ABC method performs better than the other methods when data are generated from skewed or heavy-tailed distributions. The corresponding average relative error (ARE) approaches zero as sample size increases. In data generated from the normal distribution, our ABC performs well. However, the Wan et al. method is best for estimating standard deviation under normal distribution. In the estimation of the mean, our ABC method is best regardless of assumed distribution. ABC is a flexible method for estimating the study-specific mean and standard deviation for meta-analysis, especially with underlying skewed or heavy-tailed distributions. The ABC method can be applied using other reported summary statistics such as the posterior mean and 95 % credible interval when Bayesian analysis has been employed.
ENHANCING TEST SENSITIVITY IN TOXICITY TESTING BY USING A STATISTICAL PERFORMANCE STANDARD
Previous reports have shown that within-test sensitivity can vary markedly among laboratories. Experts have advocated an empirical approach to controlling test variability based on the MSD, control means, and other test acceptability criteria. (The MSD represents the smallest dif...
On Teaching about the Coefficient of Variation in Introductory Statistics Courses
ERIC Educational Resources Information Center
Trafimow, David
2014-01-01
The standard deviation is related to the mean by virtue of the coefficient of variation. Teachers of statistics courses can make use of that fact to make the standard deviation more comprehensible for statistics students.
Got power? A systematic review of sample size adequacy in health professions education research.
Cook, David A; Hatala, Rose
2015-03-01
Many education research studies employ small samples, which in turn lowers statistical power. We re-analyzed the results of a meta-analysis of simulation-based education to determine study power across a range of effect sizes, and the smallest effect that could be plausibly excluded. We systematically searched multiple databases through May 2011, and included all studies evaluating simulation-based education for health professionals in comparison with no intervention or another simulation intervention. Reviewers working in duplicate abstracted information to calculate standardized mean differences (SMD's). We included 897 original research studies. Among the 627 no-intervention-comparison studies the median sample size was 25. Only two studies (0.3%) had ≥80% power to detect a small difference (SMD > 0.2 standard deviations) and 136 (22%) had power to detect a large difference (SMD > 0.8). 110 no-intervention-comparison studies failed to find a statistically significant difference, but none excluded a small difference and only 47 (43%) excluded a large difference. Among 297 studies comparing alternate simulation approaches the median sample size was 30. Only one study (0.3%) had ≥80% power to detect a small difference and 79 (27%) had power to detect a large difference. Of the 128 studies that did not detect a statistically significant effect, 4 (3%) excluded a small difference and 91 (71%) excluded a large difference. In conclusion, most education research studies are powered only to detect effects of large magnitude. For most studies that do not reach statistical significance, the possibility of large and important differences still exists.
NASA Technical Reports Server (NTRS)
Yamada, Toshishige; Saini, Subhash (Technical Monitor)
1998-01-01
Adatom chains, precise structures artificially created on an atomically regulated surface, are the smallest possible candidates for future nanoelectronics. Since all the devices are created by combining adatom chains precisely prepared with atomic precision, device characteristics are predictable, and free from deviations due to accidental structural defects. In this atomic dimension, however, an analogy to the current semiconductor devices may not work. For example, Si structures are not always semiconducting. Adatom states do not always localize at the substrate surface when adatoms form chemical bonds to the substrate atoms. Transport properties are often determined for the entire system of the chain and electrodes, and not for chains only. These fundamental issues are discussed, which will be useful for future device considerations.
Kery, M.; Matthies, D.; Schmid, B.
2003-01-01
We studied ecological consequences of distyly for the declining perennial plant Primula veris in the Swiss Jura. Distyly favours cross-fertilization and avoids inbreeding, but may lead to pollen limitation and reduced reproduction if morph frequencies deviate from 50 %. Disassortative mating is promoted by the reciprocal position of stigmas and anthers in the two morphs (pin and thrum) and by intramorph incompatibility and should result in equal frequencies of morphs at equilibrium. However, deviations could arise because of demographic stochasticity, the lower intra-morph incompatibility of the pin morph, and niche differentiation between morphs. Demographic stochasticity should result in symmetric deviations from an even morph frequency among populations and in increased deviations with decreasing population size. If crosses between pins occurred, these would only generate pins, and this could result in a pin-bias of morph frequencies in general and in small populations in particular. If the morphs have different niches, morph frequencies should be related to environmental factors, morphs might be spatially segregated, and morphological differences between morphs would be expected. We tested these hypotheses in the declining distylous P. veris. We studied morph frequencies in relation to environmental conditions and population size, spatial segregation in field populations, morphological differences between morphs, and growth responses to nutrient addition. Morph frequencies in 76 populations with 1 - 80000 flowering plants fluctuated symmetrically about 50 %. Deviations from 50 % were much larger in small populations, and sixof the smallest populations had lost one morph altogether. In contrast, morph frequencies were neither related to population size nor to 17 measures of environmental conditions. We found no spatial segregation or morphological differences in the field or in the common garden. The results suggest that demographic stochasticity caused deviations of the morph ratiofrom unity in small populations. Demographic stochasticity was probably caused by the random elimination of plants during the fragmentation of formerly large continuous populations. Biased morph frequencies may be one of the reasons for the strongly reduced reproduction in small populations of P. veris.
A SIMPLE METHOD FOR EVALUATING DATA FROM AN INTERLABORATORY STUDY
Large-scale laboratory-and method-performance studies involving more than about 30 laboratories may be evaluated by calculating the HORRAT ratio for each test sample (HORRAT=[experimentally found among-laboratories relative standard deviation] divided by [relative standard deviat...
Morikawa, Kei; Kurimoto, Noriaki; Inoue, Takeo; Mineshita, Masamichi; Miyazawa, Teruomi
2015-01-01
Endobronchial ultrasonography using a guide sheath (EBUS-GS) is an increasingly common bronchoscopic technique, but currently, no methods have been established to quantitatively evaluate EBUS images of peripheral pulmonary lesions. The purpose of this study was to evaluate whether histogram data collected from EBUS-GS images can contribute to the diagnosis of lung cancer. Histogram-based analyses focusing on the brightness of EBUS images were retrospectively conducted: 60 patients (38 lung cancer; 22 inflammatory diseases), with clear EBUS images were included. For each patient, a 400-pixel region of interest was selected, typically located at a 3- to 5-mm radius from the probe, from recorded EBUS images during bronchoscopy. Histogram height, width, height/width ratio, standard deviation, kurtosis and skewness were investigated as diagnostic indicators. Median histogram height, width, height/width ratio and standard deviation were significantly different between lung cancer and benign lesions (all p < 0.01). With a cutoff value for standard deviation of 10.5, lung cancer could be diagnosed with an accuracy of 81.7%. Other characteristics investigated were inferior when compared to histogram standard deviation. Histogram standard deviation appears to be the most useful characteristic for diagnosing lung cancer using EBUS images. © 2015 S. Karger AG, Basel.
Role of the standard deviation in the estimation of benchmark doses with continuous data.
Gaylor, David W; Slikker, William
2004-12-01
For continuous data, risk is defined here as the proportion of animals with values above a large percentile, e.g., the 99th percentile or below the 1st percentile, for the distribution of values among control animals. It is known that reducing the standard deviation of measurements through improved experimental techniques will result in less stringent (higher) doses for the lower confidence limit on the benchmark dose that is estimated to produce a specified risk of animals with abnormal levels for a biological effect. Thus, a somewhat larger (less stringent) lower confidence limit is obtained that may be used as a point of departure for low-dose risk assessment. It is shown in this article that it is important for the benchmark dose to be based primarily on the standard deviation among animals, s(a), apart from the standard deviation of measurement errors, s(m), within animals. If the benchmark dose is incorrectly based on the overall standard deviation among average values for animals, which includes measurement error variation, the benchmark dose will be overestimated and the risk will be underestimated. The bias increases as s(m) increases relative to s(a). The bias is relatively small if s(m) is less than one-third of s(a), a condition achieved in most experimental designs.
Statistical models for estimating daily streamflow in Michigan
Holtschlag, D.J.; Salehi, Habib
1992-01-01
Statistical models for estimating daily streamflow were analyzed for 25 pairs of streamflow-gaging stations in Michigan. Stations were paired by randomly choosing a station operated in 1989 at which 10 or more years of continuous flow data had been collected and at which flow is virtually unregulated; a nearby station was chosen where flow characteristics are similar. Streamflow data from the 25 randomly selected stations were used as the response variables; streamflow data at the nearby stations were used to generate a set of explanatory variables. Ordinary-least squares regression (OLSR) equations, autoregressive integrated moving-average (ARIMA) equations, and transfer function-noise (TFN) equations were developed to estimate the log transform of flow for the 25 randomly selected stations. The precision of each type of equation was evaluated on the basis of the standard deviation of the estimation errors. OLSR equations produce one set of estimation errors; ARIMA and TFN models each produce l sets of estimation errors corresponding to the forecast lead. The lead-l forecast is the estimate of flow l days ahead of the most recent streamflow used as a response variable in the estimation. In this analysis, the standard deviation of lead l ARIMA and TFN forecast errors were generally lower than the standard deviation of OLSR errors for l < 2 days and l < 9 days, respectively. Composite estimates were computed as a weighted average of forecasts based on TFN equations and backcasts (forecasts of the reverse-ordered series) based on ARIMA equations. The standard deviation of composite errors varied throughout the length of the estimation interval and generally was at maximum near the center of the interval. For comparison with OLSR errors, the mean standard deviation of composite errors were computed for intervals of length 1 to 40 days. The mean standard deviation of length-l composite errors were generally less than the standard deviation of the OLSR errors for l < 32 days. In addition, the composite estimates ensure a gradual transition between periods of estimated and measured flows. Model performance among stations of differing model error magnitudes were compared by computing ratios of the mean standard deviation of the length l composite errors to the standard deviation of OLSR errors. The mean error ratio for the set of 25 selected stations was less than 1 for intervals l < 32 days. Considering the frequency characteristics of the length of intervals of estimated record in Michigan, the effective mean error ratio for intervals < 30 days was 0.52. Thus, for intervals of estimation of 1 month or less, the error of the composite estimate is substantially lower than error of the OLSR estimate.
Robust geographically weighted regression of modeling the Air Polluter Standard Index (APSI)
NASA Astrophysics Data System (ADS)
Warsito, Budi; Yasin, Hasbi; Ispriyanti, Dwi; Hoyyi, Abdul
2018-05-01
The Geographically Weighted Regression (GWR) model has been widely applied to many practical fields for exploring spatial heterogenity of a regression model. However, this method is inherently not robust to outliers. Outliers commonly exist in data sets and may lead to a distorted estimate of the underlying regression model. One of solution to handle the outliers in the regression model is to use the robust models. So this model was called Robust Geographically Weighted Regression (RGWR). This research aims to aid the government in the policy making process related to air pollution mitigation by developing a standard index model for air polluter (Air Polluter Standard Index - APSI) based on the RGWR approach. In this research, we also consider seven variables that are directly related to the air pollution level, which are the traffic velocity, the population density, the business center aspect, the air humidity, the wind velocity, the air temperature, and the area size of the urban forest. The best model is determined by the smallest AIC value. There are significance differences between Regression and RGWR in this case, but Basic GWR using the Gaussian kernel is the best model to modeling APSI because it has smallest AIC.
Code of Federal Regulations, 2012 CFR
2012-07-01
... additive deterioration factor of zero to measured CO2 emissions unless good engineering judgment indicates... eliminated from the pool. (v) Select the tested subconfiguration with the smallest absolute difference...
Tang, Hsin-Chieh; Chen, Calvin Yu-Chian
2014-01-01
Glucagon-like peptide-1 (GLP-1) is a promising target for diabetes mellitus (DM) therapy and reduces the occurrence of diabetes due to obesity. However, GLP-1 will be hydrolyzed soon by the enzyme dipeptidyl peptidase-4 (DPP-4). We tried to design small molecular drugs for GLP-1 receptor agonist from the world's largest traditional Chinese medicine (TCM) Database@Taiwan. According to docking results of virtual screening, we selected 2 TCM compounds, wenyujinoside and 28-deglucosylchikusetsusaponin IV, for further molecular dynamics (MD) simulation. GLP-1 was assigned as the control compound. Based on the results of root mean square deviation (RMSD), solvent accessible surface (SAS), mean square deviation (MSD), Gyrate, total energy, root mean square fluctuation (RMSF), matrices of smallest distance of residues, database of secondary structure assignment (DSSP), cluster analysis, and distance of H-bond, we concluded that all the 3 compounds could bind and activate GLP-1 receptor by computational simulation. Wenyujinoside and 28-deglucosylchikusetsusaponin IV were the TCM compounds that could be GLP-1 receptor agonists. PMID:24891870
Tang, Hsin-Chieh; Chen, Calvin Yu-Chian
2014-01-01
Glucagon-like peptide-1 (GLP-1) is a promising target for diabetes mellitus (DM) therapy and reduces the occurrence of diabetes due to obesity. However, GLP-1 will be hydrolyzed soon by the enzyme dipeptidyl peptidase-4 (DPP-4). We tried to design small molecular drugs for GLP-1 receptor agonist from the world's largest traditional Chinese medicine (TCM) Database@Taiwan. According to docking results of virtual screening, we selected 2 TCM compounds, wenyujinoside and 28-deglucosylchikusetsusaponin IV, for further molecular dynamics (MD) simulation. GLP-1 was assigned as the control compound. Based on the results of root mean square deviation (RMSD), solvent accessible surface (SAS), mean square deviation (MSD), Gyrate, total energy, root mean square fluctuation (RMSF), matrices of smallest distance of residues, database of secondary structure assignment (DSSP), cluster analysis, and distance of H-bond, we concluded that all the 3 compounds could bind and activate GLP-1 receptor by computational simulation. Wenyujinoside and 28-deglucosylchikusetsusaponin IV were the TCM compounds that could be GLP-1 receptor agonists.
Worldwide Survey of Alcohol and Nonmedical Drug Use among Military Personnel: 1982,
1983-01-01
cell . The first number is an estimate of the percentage of the population with the characteristics that define the cell . The second number, in...multiplying 1.96 times the standard error for that cell . (Obviously, for very small or very large estimates, the respective smallest or largest value in...that the cell proportions estimate the true population value more precisely, and larger standard errors indicate that the true population value is
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 4 2010-01-01 2010-01-01 false Deviations. 961.4 Section 961.4 Energy DEPARTMENT OF ENERGY STANDARD CONTRACT FOR DISPOSAL OF SPENT NUCLEAR FUEL AND/OR HIGH-LEVEL RADIOACTIVE WASTE General § 961.4 Deviations. Requests for authority to deviate from this part shall be submitted in writing to...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 4 2012-01-01 2012-01-01 false Deviations. 961.4 Section 961.4 Energy DEPARTMENT OF ENERGY STANDARD CONTRACT FOR DISPOSAL OF SPENT NUCLEAR FUEL AND/OR HIGH-LEVEL RADIOACTIVE WASTE General § 961.4 Deviations. Requests for authority to deviate from this part shall be submitted in writing to...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 4 2014-01-01 2014-01-01 false Deviations. 961.4 Section 961.4 Energy DEPARTMENT OF ENERGY STANDARD CONTRACT FOR DISPOSAL OF SPENT NUCLEAR FUEL AND/OR HIGH-LEVEL RADIOACTIVE WASTE General § 961.4 Deviations. Requests for authority to deviate from this part shall be submitted in writing to...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 4 2013-01-01 2013-01-01 false Deviations. 961.4 Section 961.4 Energy DEPARTMENT OF ENERGY STANDARD CONTRACT FOR DISPOSAL OF SPENT NUCLEAR FUEL AND/OR HIGH-LEVEL RADIOACTIVE WASTE General § 961.4 Deviations. Requests for authority to deviate from this part shall be submitted in writing to...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 4 2011-01-01 2011-01-01 false Deviations. 961.4 Section 961.4 Energy DEPARTMENT OF ENERGY STANDARD CONTRACT FOR DISPOSAL OF SPENT NUCLEAR FUEL AND/OR HIGH-LEVEL RADIOACTIVE WASTE General § 961.4 Deviations. Requests for authority to deviate from this part shall be submitted in writing to...
Santric-Milicevic, M; Vasic, V; Terzic-Supic, Z
2016-08-15
In times of austerity, the availability of econometric health knowledge assists policy-makers in understanding and balancing health expenditure with health care plans within fiscal constraints. The objective of this study is to explore whether the health workforce supply of the public health care sector, population number, and utilization of inpatient care significantly contribute to total health expenditure. The dependent variable is the total health expenditure (THE) in Serbia from the years 2003 to 2011. The independent variables are the number of health workers employed in the public health care sector, population number, and inpatient care discharges per 100 population. The statistical analyses include the quadratic interpolation method, natural logarithm and differentiation, and multiple linear regression analyses. The level of significance is set at P < 0.05. The regression model captures 90 % of all variations of observed dependent variables (adjusted R square), and the model is significant (P < 0.001). Total health expenditure increased by 1.21 standard deviations, with an increase in health workforce growth rate by 1 standard deviation. Furthermore, this rate decreased by 1.12 standard deviations, with an increase in (negative) population growth rate by 1 standard deviation. Finally, the growth rate increased by 0.38 standard deviation, with an increase of the growth rate of inpatient care discharges per 100 population by 1 standard deviation (P < 0.001). Study results demonstrate that the government has been making an effort to control strongly health budget growth. Exploring causality relationships between health expenditure and health workforce is important for countries that are trying to consolidate their public health finances and achieve universal health coverage at the same time.
The truly remarkable universality of half a standard deviation: confirmation through another look.
Norman, Geoffrey R; Sloan, Jeff A; Wyrwich, Kathleen W
2004-10-01
In this issue of Expert Review of Pharmacoeconomics and Outcomes Research, Farivar, Liu, and Hays present their findings in 'Another look at the half standard deviation estimate of the minimally important difference in health-related quality of life scores (hereafter referred to as 'Another look') . These researchers have re-examined the May 2003 Medical Care article 'Interpretation of changes in health-related quality of life: the remarkable universality of half a standard deviation' (hereafter referred to as 'Remarkable') in the hope of supporting their hypothesis that the minimally important difference in health-related quality of life measures is undoubtedly closer to 0.3 standard deviations than 0.5. Nonetheless, despite their extensive wranglings with the exclusion of many articles that we included in our review; the inclusion of articles that we did not include in our review; and the recalculation of effect sizes using the absolute value of the mean differences, in our opinion, the results of the 'Another look' article confirm the same findings in the 'Remarkable' paper.
Static Scene Statistical Non-Uniformity Correction
2015-03-01
Error NUC Non-Uniformity Correction RMSE Root Mean Squared Error RSD Relative Standard Deviation S3NUC Static Scene Statistical Non-Uniformity...Deviation ( RSD ) which normalizes the standard deviation, σ, to the mean estimated value, µ using the equation RS D = σ µ × 100. The RSD plot of the gain...estimates is shown in Figure 4.1(b). The RSD plot shows that after a sample size of approximately 10, the different photocount values and the inclusion
Effect of multizone refractive multifocal contact lenses on standard automated perimetry.
Madrid-Costa, David; Ruiz-Alcocer, Javier; García-Lázaro, Santiago; Albarrán-Diego, César; Ferrer-Blasco, Teresa
2012-09-01
The aim of this study was to evaluate whether the creation of 2 foci (distance and near) provided by multizone refractive multifocal contact lenses (CLs) for presbyopia correction affects the measurements on Humphreys 24-2 Swedish interactive threshold algorithm (SITA) standard automated perimetry (SAP). In this crossover study, 30 subjects were fitted in random order with either a multifocal CL or a monofocal CL. After 1 month, a Humphrey 24-2 SITA standard strategy was performed. The visual field global indices (the mean deviation [MD] and pattern standard deviation [PSD]), reliability indices, test duration, and number of depressed points deviating at P<5%, P<2%, P<1%, and P<0.5% on pattern deviation probability plots were determined and compared between multifocal and monofocal CLs. Thirty eyes of 30 subjects were included in this study. There were no statistically significant differences in reliability indices or test duration. There was a statistically significant reduction in the MD with the multifocal CL compared with monfocal CL (P=0.001). Differences were not found in PSD nor in the number of depressed points deviating at P<5%, P<2%, P<1%, and P<0.5% in the pattern deviation probability maps studied. The results of this study suggest that the multizone refractive lens produces a generalized depression in threshold sensitivity as measured by the Humphreys 24-2 SITA SAP.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Standards for Grades of Apples Definitions § 51.320 Diameter. When measuring for minimum size, “diameter” means the greatest dimension of the apple measured at right angles to a line from stem to blossom end. When measuring for maximum size, “diameter” means the smallest dimension of the apple determined by...
Code of Federal Regulations, 2011 CFR
2011-01-01
... Standards for Grades of Apples Definitions § 51.320 Diameter. When measuring for minimum size, “diameter” means the greatest dimension of the apple measured at right angles to a line from stem to blossom end. When measuring for maximum size, “diameter” means the smallest dimension of the apple determined by...
Code of Federal Regulations, 2010 CFR
2010-01-01
... Standards for Grades of Apples Definitions § 51.320 Diameter. When measuring for minimum size, “diameter” means the greatest dimension of the apple measured at right angles to a line from stem to blossom end. When measuring for maximum size, “diameter” means the smallest dimension of the apple determined by...
32 CFR 2001.53 - Open storage areas.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 32 National Defense 6 2012-07-01 2012-07-01 false Open storage areas. 2001.53 Section 2001.53....53 Open storage areas. This section describes the minimum construction standards for open storage... in its smallest dimension) that enter or pass through an open storage area shall be protected with...
32 CFR 2001.53 - Open storage areas.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 32 National Defense 6 2014-07-01 2014-07-01 false Open storage areas. 2001.53 Section 2001.53....53 Open storage areas. This section describes the minimum construction standards for open storage... in its smallest dimension) that enter or pass through an open storage area shall be protected with...
Chow, Steven Kwok Keung; Yeung, David Ka Wai; Ahuja, Anil T; King, Ann D
2012-01-01
Purpose To quantitatively evaluate the kinetic parameter estimation for head and neck (HN) dynamic contrast-enhanced (DCE) MRI with dual-flip-angle (DFA) T1 mapping. Materials and methods Clinical DCE-MRI datasets of 23 patients with HN tumors were included in this study. T1 maps were generated based on multiple-flip-angle (MFA) method and different DFA combinations. Tofts model parameter maps of kep, Ktrans and vp based on MFA and DFAs were calculated and compared. Fitted parameter by MFA and DFAs were quantitatively evaluated in primary tumor, salivary gland and muscle. Results T1 mapping deviations by DFAs produced remarkable kinetic parameter estimation deviations in head and neck tissues. In particular, the DFA of [2º, 7º] overestimated, while [7º, 12º] and [7º, 15º] underestimated Ktrans and vp, significantly (P<0.01). [2º, 15º] achieved the smallest but still statistically significant overestimation for Ktrans and vp in primary tumors, 32.1% and 16.2% respectively. kep fitting results by DFAs were relatively close to the MFA reference compared to Ktrans and vp. Conclusions T1 deviations induced by DFA could result in significant errors in kinetic parameter estimation, particularly Ktrans and vp, through Tofts model fitting. MFA method should be more reliable and robust for accurate quantitative pharmacokinetic analysis in head and neck. PMID:23289084
Stenzel, O; Wilbrandt, S; Wolf, J; Schürmann, M; Kaiser, N; Ristau, D; Ehlers, H; Carstens, F; Schippel, S; Mechold, L; Rauhut, R; Kennedy, M; Bischoff, M; Nowitzki, T; Zöller, A; Hagedorn, H; Reus, H; Hegemann, T; Starke, K; Harhausen, J; Foest, R; Schumacher, J
2017-02-01
Random effects in the repeatability of refractive index and absorption edge position of tantalum pentoxide layers prepared by plasma-ion-assisted electron-beam evaporation, ion beam sputtering, and magnetron sputtering are investigated and quantified. Standard deviations in refractive index between 4*10-4 and 4*10-3 have been obtained. Here, lowest standard deviations in refractive index close to our detection threshold could be achieved by both ion beam sputtering and plasma-ion-assisted deposition. In relation to the corresponding mean values, the standard deviations in band-edge position and refractive index are of similar order.
Closed-form confidence intervals for functions of the normal mean and standard deviation.
Donner, Allan; Zou, G Y
2012-08-01
Confidence interval methods for a normal mean and standard deviation are well known and simple to apply. However, the same cannot be said for important functions of these parameters. These functions include the normal distribution percentiles, the Bland-Altman limits of agreement, the coefficient of variation and Cohen's effect size. We present a simple approach to this problem by using variance estimates recovered from confidence limits computed for the mean and standard deviation separately. All resulting confidence intervals have closed forms. Simulation results demonstrate that this approach performs very well for limits of agreement, coefficients of variation and their differences.
McClure, Foster D; Lee, Jung K
2005-01-01
Sample size formulas are developed to estimate the repeatability and reproducibility standard deviations (Sr and S(R)) such that the actual error in (Sr and S(R)) relative to their respective true values, sigmar and sigmaR, are at predefined levels. The statistical consequences associated with AOAC INTERNATIONAL required sample size to validate an analytical method are discussed. In addition, formulas to estimate the uncertainties of (Sr and S(R)) were derived and are provided as supporting documentation. Formula for the Number of Replicates Required for a Specified Margin of Relative Error in the Estimate of the Repeatability Standard Deviation.
Pleil, Joachim D
2016-01-01
This commentary is the second of a series outlining one specific concept in interpreting biomarkers data. In the first, an observational method was presented for assessing the distribution of measurements before making parametric calculations. Here, the discussion revolves around the next step, the choice of using standard error of the mean or the calculated standard deviation to compare or predict measurement results.
Introducing the Mean Absolute Deviation "Effect" Size
ERIC Educational Resources Information Center
Gorard, Stephen
2015-01-01
This paper revisits the use of effect sizes in the analysis of experimental and similar results, and reminds readers of the relative advantages of the mean absolute deviation as a measure of variation, as opposed to the more complex standard deviation. The mean absolute deviation is easier to use and understand, and more tolerant of extreme…
Hopper, John L.
2015-01-01
How can the “strengths” of risk factors, in the sense of how well they discriminate cases from controls, be compared when they are measured on different scales such as continuous, binary, and integer? Given that risk estimates take into account other fitted and design-related factors—and that is how risk gradients are interpreted—so should the presentation of risk gradients. Therefore, for each risk factor X0, I propose using appropriate regression techniques to derive from appropriate population data the best fitting relationship between the mean of X0 and all the other covariates fitted in the model or adjusted for by design (X1, X2, … , Xn). The odds per adjusted standard deviation (OPERA) presents the risk association for X0 in terms of the change in risk per s = standard deviation of X0 adjusted for X1, X2, … , Xn, rather than the unadjusted standard deviation of X0 itself. If the increased risk is relative risk (RR)-fold over A adjusted standard deviations, then OPERA = exp[ln(RR)/A] = RRs. This unifying approach is illustrated by considering breast cancer and published risk estimates. OPERA estimates are by definition independent and can be used to compare the predictive strengths of risk factors across diseases and populations. PMID:26520360
NASA Astrophysics Data System (ADS)
Muji Susantoro, Tri; Wikantika, Ketut; Saepuloh, Asep; Handoyo Harsolumakso, Agus
2018-05-01
Selection of vegetation indices in plant mapping is needed to provide the best information of plant conditions. The methods used in this research are the standard deviation and the linear regression. This research tried to determine the vegetation indices used for mapping the sugarcane conditions around oil and gas fields. The data used in this study is Landsat 8 OLI/TIRS. The standard deviation analysis on the 23 vegetation indices with 27 samples has resulted in the six highest standard deviations of vegetation indices, termed as GRVI, SR, NLI, SIPI, GEMI and LAI. The standard deviation values are 0.47; 0.43; 0.30; 0.17; 0.16 and 0.13. Regression correlation analysis on the 23 vegetation indices with 280 samples has resulted in the six vegetation indices, termed as NDVI, ENDVI, GDVI, VARI, LAI and SIPI. This was performed based on regression correlation with the lowest value R2 than 0,8. The combined analysis of the standard deviation and the regression correlation has obtained the five vegetation indices, termed as NDVI, ENDVI, GDVI, LAI and SIPI. The results of the analysis of both methods show that a combination of two methods needs to be done to produce a good analysis of sugarcane conditions. It has been clarified through field surveys and showed good results for the prediction of microseepages.
Remote auditing of radiotherapy facilities using optically stimulated luminescence dosimeters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lye, Jessica, E-mail: jessica.lye@arpansa.gov.au; Dunn, Leon; Kenny, John
Purpose: On 1 July 2012, the Australian Clinical Dosimetry Service (ACDS) released its Optically Stimulated Luminescent Dosimeter (OSLD) Level I audit, replacing the previous TLD based audit. The aim of this work is to present the results from this new service and the complete uncertainty analysis on which the audit tolerances are based. Methods: The audit release was preceded by a rigorous evaluation of the InLight® nanoDot OSLD system from Landauer (Landauer, Inc., Glenwood, IL). Energy dependence, signal fading from multiple irradiations, batch variation, reader variation, and dose response factors were identified and quantified for each individual OSLD. The detectorsmore » are mailed to the facility in small PMMA blocks, based on the design of the existing Radiological Physics Centre audit. Modeling and measurement were used to determine a factor that could convert the dose measured in the PMMA block, to dose in water for the facility's reference conditions. This factor is dependent on the beam spectrum. The TPR{sub 20,10} was used as the beam quality index to determine the specific block factor for a beam being audited. The audit tolerance was defined using a rigorous uncertainty calculation. The audit outcome is then determined using a scientifically based two tiered action level approach. Audit outcomes within two standard deviations were defined as Pass (Optimal Level), within three standard deviations as Pass (Action Level), and outside of three standard deviations the outcome is Fail (Out of Tolerance). Results: To-date the ACDS has audited 108 photon beams with TLD and 162 photon beams with OSLD. The TLD audit results had an average deviation from ACDS of 0.0% and a standard deviation of 1.8%. The OSLD audit results had an average deviation of −0.2% and a standard deviation of 1.4%. The relative combined standard uncertainty was calculated to be 1.3% (1σ). Pass (Optimal Level) was reduced to ≤2.6% (2σ), and Fail (Out of Tolerance) was reduced to >3.9% (3σ) for the new OSLD audit. Previously with the TLD audit the Pass (Optimal Level) and Fail (Out of Tolerance) were set at ≤4.0% (2σ) and >6.0% (3σ). Conclusions: The calculated standard uncertainty of 1.3% at one standard deviation is consistent with the measured standard deviation of 1.4% from the audits and confirming the suitability of the uncertainty budget derived audit tolerances. The OSLD audit shows greater accuracy than the previous TLD audit, justifying the reduction in audit tolerances. In the TLD audit, all outcomes were Pass (Optimal Level) suggesting that the tolerances were too conservative. In the OSLD audit 94% of the audits have resulted in Pass (Optimal level) and 6% of the audits have resulted in Pass (Action Level). All Pass (Action level) results have been resolved with a repeat OSLD audit, or an on-site ion chamber measurement.« less
Collinearity in Least-Squares Analysis
ERIC Educational Resources Information Center
de Levie, Robert
2012-01-01
How useful are the standard deviations per se, and how reliable are results derived from several least-squares coefficients and their associated standard deviations? When the output parameters obtained from a least-squares analysis are mutually independent, as is often assumed, they are reliable estimators of imprecision and so are the functions…
Robust Confidence Interval for a Ratio of Standard Deviations
ERIC Educational Resources Information Center
Bonett, Douglas G.
2006-01-01
Comparing variability of test scores across alternate forms, test conditions, or subpopulations is a fundamental problem in psychometrics. A confidence interval for a ratio of standard deviations is proposed that performs as well as the classic method with normal distributions and performs dramatically better with nonnormal distributions. A simple…
Standard Deviation for Small Samples
ERIC Educational Resources Information Center
Joarder, Anwar H.; Latif, Raja M.
2006-01-01
Neater representations for variance are given for small sample sizes, especially for 3 and 4. With these representations, variance can be calculated without a calculator if sample sizes are small and observations are integers, and an upper bound for the standard deviation is immediate. Accessible proofs of lower and upper bounds are presented for…
Estimating maize water stress by standard deviation of canopy temperature in thermal imagery
USDA-ARS?s Scientific Manuscript database
A new crop water stress index using standard deviation of canopy temperature as an input was developed to monitor crop water status. In this study, thermal imagery was taken from maize under various levels of deficit irrigation treatments in different crop growing stages. The Expectation-Maximizatio...
Experiments with central-limit properties of spatial samples from locally covariant random fields
Barringer, T.H.; Smith, T.E.
1992-01-01
When spatial samples are statistically dependent, the classical estimator of sample-mean standard deviation is well known to be inconsistent. For locally dependent samples, however, consistent estimators of sample-mean standard deviation can be constructed. The present paper investigates the sampling properties of one such estimator, designated as the tau estimator of sample-mean standard deviation. In particular, the asymptotic normality properties of standardized sample means based on tau estimators are studied in terms of computer experiments with simulated sample-mean distributions. The effects of both sample size and dependency levels among samples are examined for various value of tau (denoting the size of the spatial kernel for the estimator). The results suggest that even for small degrees of spatial dependency, the tau estimator exhibits significantly stronger normality properties than does the classical estimator of standardized sample means. ?? 1992.
YALE NATURAL RADIOCARBON MEASUREMENTS. PART VI
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stuiver, M.; Deevey, E.S.
1961-01-01
Most of the measurements made since publication of Yale V are included; some measurements, such as a series collected in Greenland, are withneld pending additional information or field work that will make better interpretations possible. In addition to radiocarbon dates of geologic and/or archaeologic interest, recent assays are given of C/sup 14/ in lake waters and other lacustrine materials, now normalized for C/sup 13/ content. The newly accepted convention is followed in expressing normalized C/sup 14/ values as DELTA = delta C/sup 14/ (2 delta C/sup 13/ + 50)STAl + ( delta C/sup 14//1000)! where DELTA is the per milmore » deviation of the C/sup 14/ if the sample from any contemporary standard (whether organic or a carbonate) after correction of sample and/or standard for real age, for the Suess effect, for normal isotopic fractionation, and for deviations of C/sup 14/ content of the age- and pollution- corrected l9th-century wood standard from that of 95% of the NBS oxalic acid standard; delta C/sup 14/ is the measured deviation from 95% of the NBS standard, and delta C/sup 13/ is the deviation from the NBS limestone standard, both in per mil. These assays are variously affected by artificial C/sup 14/ resulting from nuclear tests. (auth)« less
Yanagihara, Nobuyuki; Seki, Meikan; Nakano, Masahiro; Hachisuga, Toru; Goto, Yukio
2014-06-01
Disturbance of autonomic nervous activity has been thought to play a role in the climacteric symptoms of postmenopausal women. This study was therefore designed to investigate the relationship between autonomic nervous activity and climacteric symptoms in postmenopausal Japanese women. The autonomic nervous activity of 40 Japanese women with climacteric symptoms and 40 Japanese women without climacteric symptoms was measured by power spectral analysis of heart rate variability using a standard hexagonal radar chart. The scores for climacteric symptoms were determined using the simplified menopausal index. Sympathetic excitability and irritability, as well as the standard deviation of mean R-R intervals in supine position, were significantly (P < 0.01, 0.05, and 0.001, respectively) decreased in women with climacteric symptoms. There was a negative correlation between the standard deviation of mean R-R intervals in supine position and the simplified menopausal index score. The lack of control for potential confounding variables was a limitation of this study. In climacteric women, the standard deviation of mean R-R intervals in supine position is negatively correlated with the simplified menopausal index score.
Zukowski, Lisa A; Christou, Evangelos A; Shechtman, Orit; Hass, Christopher J; Tillman, Mark D
2017-03-01
Wheelchair propulsion has been linked to overuse injuries regardless of propulsion style. Many aspects of the arcing (ARC) and semicircular (SEMI) propulsion styles have been compared, but differences in intracycle movement variability, which have been linked to overuse injuries, have not been examined. To explore how ARC and SEMI affect changes in intracycle wrist movement variability after a fatiguing bout of propulsion. Repeated measures crossover design. Wheelchair rollers and wheelchair fatigue course in a research laboratory. Twenty healthy, nondisabled adult men without previous wheelchair experience. Participants learned ARC and SEMI and used each to perform a wheelchair fatigue protocol. Thirty seconds of propulsion on rollers were recorded by motion-capture cameras before and after a fatigue protocol for each propulsion style on 2 testing days. Angular wrist orientations (flexion/extension and radial/ulnar deviation) and linear wrist trajectories (mediolateral direction) were computed, and intracycle movement variability was calculated as standard deviations of the detrended and filtered values during the push phase beginning and end. Paired samples t tests were used to compare ARC and SEMI based on the percent changes from pre- to postfatigue protocol. Both propulsion styles resulted in increased intracycle wrist movement variability postfatigue, but observed increases did not significantly differ between ARC and SEMI. This study evinces that intersubject variability exceeded average changes in intracycle wrist movement variability for both propulsion styles. Neither propulsion style resulting in a greater change in intracycle movement variability may suggest that no single propulsion style is ideal for everyone. The large intersubject variability may indicate that the propulsion style resulting in the smallest increase in intracycle movement variability after a fatiguing bout of propulsion may differ for each person and may help explain why wheelchair users self-select to use different propulsion styles. Copyright © 2017 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Száz, Dénes; Farkas, Alexandra; Barta, András; Kretzer, Balázs; Egri, Ádám; Horváth, Gábor
2016-07-01
The theory of sky-polarimetric Viking navigation has been widely accepted for decades without any information about the accuracy of this method. Previously, we have measured the accuracy of the first and second steps of this navigation method in psychophysical laboratory and planetarium experiments. Now, we have tested the accuracy of the third step in a planetarium experiment, assuming that the first and second steps are errorless. Using the fists of their outstretched arms, 10 test persons had to estimate the elevation angles (measured in numbers of fists and fingers) of black dots (representing the position of the occluded Sun) projected onto the planetarium dome. The test persons performed 2400 elevation estimations, 48% of which were more accurate than ±1°. We selected three test persons with the (i) largest and (ii) smallest elevation errors and (iii) highest standard deviation of the elevation error. From the errors of these three persons, we calculated their error function, from which the North errors (the angles with which they deviated from the geographical North) were determined for summer solstice and spring equinox, two specific dates of the Viking sailing period. The range of possible North errors Δ ω N was the lowest and highest at low and high solar elevations, respectively. At high elevations, the maximal Δ ω N was 35.6° and 73.7° at summer solstice and 23.8° and 43.9° at spring equinox for the best and worst test person (navigator), respectively. Thus, the best navigator was twice as good as the worst one. At solstice and equinox, high elevations occur the most frequently during the day, thus high North errors could occur more frequently than expected before. According to our findings, the ideal periods for sky-polarimetric Viking navigation are immediately after sunrise and before sunset, because the North errors are the lowest at low solar elevations.
Száz, Dénes; Farkas, Alexandra; Barta, András; Kretzer, Balázs; Egri, Ádám
2016-01-01
The theory of sky-polarimetric Viking navigation has been widely accepted for decades without any information about the accuracy of this method. Previously, we have measured the accuracy of the first and second steps of this navigation method in psychophysical laboratory and planetarium experiments. Now, we have tested the accuracy of the third step in a planetarium experiment, assuming that the first and second steps are errorless. Using the fists of their outstretched arms, 10 test persons had to estimate the elevation angles (measured in numbers of fists and fingers) of black dots (representing the position of the occluded Sun) projected onto the planetarium dome. The test persons performed 2400 elevation estimations, 48% of which were more accurate than ±1°. We selected three test persons with the (i) largest and (ii) smallest elevation errors and (iii) highest standard deviation of the elevation error. From the errors of these three persons, we calculated their error function, from which the North errors (the angles with which they deviated from the geographical North) were determined for summer solstice and spring equinox, two specific dates of the Viking sailing period. The range of possible North errors ΔωN was the lowest and highest at low and high solar elevations, respectively. At high elevations, the maximal ΔωN was 35.6° and 73.7° at summer solstice and 23.8° and 43.9° at spring equinox for the best and worst test person (navigator), respectively. Thus, the best navigator was twice as good as the worst one. At solstice and equinox, high elevations occur the most frequently during the day, thus high North errors could occur more frequently than expected before. According to our findings, the ideal periods for sky-polarimetric Viking navigation are immediately after sunrise and before sunset, because the North errors are the lowest at low solar elevations. PMID:27493566
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sleiman, Mohamad; Chen, Sharon; Gilbert, Haley E.
A laboratory method to simulate natural exposure of roofing materials has been reported in a companion article. Here in the current article, we describe the results of an international, nine-participant interlaboratory study (ILS) conducted in accordance with ASTM Standard E691-09 to establish the precision and reproducibility of this protocol. The accelerated soiling and weathering method was applied four times by each laboratory to replicate coupons of 12 products representing a wide variety of roofing categories (single-ply membrane, factory-applied coating (on metal), bare metal, field-applied coating, asphalt shingle, modified-bitumen cap sheet, clay tile, and concrete tile). Participants reported initial and laboratory-agedmore » values of solar reflectance and thermal emittance. Measured solar reflectances were consistent within and across eight of the nine participating laboratories. Measured thermal emittances reported by six participants exhibited comparable consistency. For solar reflectance, the accelerated aging method is both repeatable and reproducible within an acceptable range of standard deviations: the repeatability standard deviation sr ranged from 0.008 to 0.015 (relative standard deviation of 1.2–2.1%) and the reproducibility standard deviation sR ranged from 0.022 to 0.036 (relative standard deviation of 3.2–5.8%). The ILS confirmed that the accelerated aging method can be reproduced by multiple independent laboratories with acceptable precision. In conclusion, this study supports the adoption of the accelerated aging practice to speed the evaluation and performance rating of new cool roofing materials.« less
Thermal comfort evaluation of three genetic lines of modern pigs using thermal images
USDA-ARS?s Scientific Manuscript database
Previous ARS research found that heat production of growing-finishing swine is 6 – 41% higher than documented in the ASABE and ASHRAE standards. The smallest changes were noted at the lightest weight pigs. This change is most likely due to larger, faster growing genotypes used in modern swine prod...
Leading Schools through Major Change
ERIC Educational Resources Information Center
Syed, Sarosh
2013-01-01
Changing even the smallest things in schools is hard--just ask any principal who has overseen a rescheduling of bus routes. So imagine the difficulty of getting a school to move its curriculum and instruction from familiar learning requirements to brand-new nationwide standards. Yet this is exactly the sort of change public schools in 45 states…
Kang, S-H; Lee, J-W; Lim, S-H; Kim, Y-H; Kim, M-K
2014-10-01
The goal of the present study was to compare the accuracy of dental image replacement on a cone beam computed tomography (CBCT) image using digital image data from three-dimensional (3D) optical scanning of a dental cast, occlusal bite, and bite tray impression. A Bracket Typodont dental model was used. CBCT of the dental model was performed and the data were converted to stereolithography (STL) format. Three experimental materials, a dental cast, occlusal bite, and bite tray impression, were optically scanned in 3D. STL files converted from the CBCT of the Typodont model and the 3D optical-scanned STL files of the study materials were image-registered. The error range of each methodology was measured and compared with a 3D optical scan of the Typodont. For the three materials, the smallest error observed was 0.099±0.114mm (mean error±standard deviation) for registering the 3D optical scan image of the dental cast onto the CBCT dental image. Although producing a dental cast can be laborious, the study results indicate that it is the preferred method. In addition, an occlusal bite is recommended when bite impression materials are used. Copyright © 2014 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Striegl, Robert G.; Wickland, K.P.
2001-01-01
Soil carbon dioxide (CO2) emission (soil respiration), net CO2 exchange after photosynthetic uptake by ground-cover plants, and soil CO2 concentration versus depth below land surface were measured at four ages of jack pine (Pinus banksiana Lamb.) forest in central Saskatchewan. Soil respiration was smallest at a clear-cut site, largest in an 8-year-old stand, and decreased with stand age in 20-year-old and mature (60-75 years old) stands during May-September 1994 (12.1, 34.6, 31.5, and 24.9 mol C??m-2, respectively). Simulations of soil respiration at each stand based on continuously recorded soil temperature were within one standard deviation of measured flux for 48 of 52 measurement periods, but were 10%-30% less than linear interpolations of measured flux for the season. This was probably due to decreased soil respiration at night modeled by the temperature-flux relationships, but not documented by daytime chamber measurements. CO2 uptake by ground-cover plants ranged from 0 at the clear-cut site to 29, 25, and 9% of total growing season soil respiration at the 8-year, 20-year, and mature stands. CO2 concentrations were as great as 7150 ppmv in the upper 1 m of unsaturated zone and were proportional to measured soil respiration.
Selection and Classification Using a Forecast Applicant Pool.
ERIC Educational Resources Information Center
Hendrix, William H.
The document presents a forecast model of the future Air Force applicant pool. By forecasting applicants' quality (means and standard deviations of aptitude scores) and quantity (total number of applicants), a potential enlistee could be compared to the forecasted pool. The data used to develop the model consisted of means, standard deviation, and…
NASA Technical Reports Server (NTRS)
Herrman, B. D.; Uman, M. A.; Brantley, R. D.; Krider, E. P.
1976-01-01
The principle of operation of a wideband crossed-loop magnetic-field direction finder is studied by comparing the bearing determined from the NS and EW magnetic fields at various times up to 155 microsec after return stroke initiation with the TV-determined lightning channel base direction. For 40 lightning strokes in the 3 to 12 km range, the difference between the bearings found from magnetic fields sampled at times between 1 and 10 microsec and the TV channel-base data has a standard deviation of 3-4 deg. Included in this standard deviation is a 2-3 deg measurement error. For fields sampled at progressively later times, both the mean and the standard deviation of the difference between the direction-finder bearing and the TV bearing increase. Near 150 microsec, means are about 35 deg and standard deviations about 60 deg. The physical reasons for the late-time inaccuracies in the wideband direction finder and the occurrence of these effects in narrow-band VLF direction finders are considered.
Wavelength selection method with standard deviation: application to pulse oximetry.
Vazquez-Jaccaud, Camille; Paez, Gonzalo; Strojnik, Marija
2011-07-01
Near-infrared spectroscopy provides useful biological information after the radiation has penetrated through the tissue, within the therapeutic window. One of the significant shortcomings of the current applications of spectroscopic techniques to a live subject is that the subject may be uncooperative and the sample undergoes significant temporal variations, due to his health status that, from radiometric point of view, introduce measurement noise. We describe a novel wavelength selection method for monitoring, based on a standard deviation map, that allows low-noise sensitivity. It may be used with spectral transillumination, transmission, or reflection signals, including those corrupted by noise and unavoidable temporal effects. We apply it to the selection of two wavelengths for the case of pulse oximetry. Using spectroscopic data, we generate a map of standard deviation that we propose as a figure-of-merit in the presence of the noise introduced by the living subject. Even in the presence of diverse sources of noise, we identify four wavelength domains with standard deviation, minimally sensitive to temporal noise, and two wavelengths domains with low sensitivity to temporal noise.
How random is a random vector?
NASA Astrophysics Data System (ADS)
Eliazar, Iddo
2015-12-01
Over 80 years ago Samuel Wilks proposed that the "generalized variance" of a random vector is the determinant of its covariance matrix. To date, the notion and use of the generalized variance is confined only to very specific niches in statistics. In this paper we establish that the "Wilks standard deviation" -the square root of the generalized variance-is indeed the standard deviation of a random vector. We further establish that the "uncorrelation index" -a derivative of the Wilks standard deviation-is a measure of the overall correlation between the components of a random vector. Both the Wilks standard deviation and the uncorrelation index are, respectively, special cases of two general notions that we introduce: "randomness measures" and "independence indices" of random vectors. In turn, these general notions give rise to "randomness diagrams"-tangible planar visualizations that answer the question: How random is a random vector? The notion of "independence indices" yields a novel measure of correlation for Lévy laws. In general, the concepts and results presented in this paper are applicable to any field of science and engineering with random-vectors empirical data.
Estimation of Tooth Size Discrepancies among Different Malocclusion Groups.
Hasija, Narender; Bala, Madhu; Goyal, Virender
2014-05-01
Regards and Tribute: Late Dr Narender Hasija was a mentor and visionary in the light of knowledge and experience. We pay our regards with deepest gratitude to the departed soul to rest in peace. Bolton's ratios help in estimating overbite, overjet relationships, the effects of contemplated extractions on posterior occlusion, incisor relationships and identification of occlusal misfit produced by tooth size discrepancies. To determine any difference in tooth size discrepancy in anterior as well as overall ratio in different malocclusions and comparison with Bolton's study. After measuring the teeth on all 100 patients, Bolton's analysis was performed. Results were compared with Bolton's means and standard deviations. The results were also subjected to statistical analysis. Results show that the mean and standard deviations of ideal occlusion cases are comparable with those Bolton but, when the mean and standard deviation of malocclusion groups are compared with those of Bolton, the values of standard deviation are higher, though the mean is comparable. How to cite this article: Hasija N, Bala M, Goyal V. Estimation of Tooth Size Discrepancies among Different Malocclusion Groups. Int J Clin Pediatr Dent 2014;7(2):82-85.
Association of auricular pressing and heart rate variability in pre-exam anxiety students.
Wu, Wocao; Chen, Junqi; Zhen, Erchuan; Huang, Huanlin; Zhang, Pei; Wang, Jiao; Ou, Yingyi; Huang, Yong
2013-03-25
A total of 30 students scoring between 12 and 20 on the Test Anxiety Scale who had been exhibiting an anxious state > 24 hours, and 30 normal control students were recruited. Indices of heart rate variability were recorded using an Actiheart electrocardiogram recorder at 10 minutes before auricular pressing, in the first half of stimulation and in the second half of stimulation. The results revealed that the standard deviation of all normal to normal intervals and the root mean square of standard deviation of normal to normal intervals were significantly increased after stimulation. The heart rate variability triangular index, very-low-frequency power, low-frequency power, and the ratio of low-frequency to high-frequency power were increased to different degrees after stimulation. Compared with normal controls, the root mean square of standard deviation of normal to normal intervals was significantly increased in anxious students following auricular pressing. These results indicated that auricular pressing can elevate heart rate variability, especially the root mean square of standard deviation of normal to normal intervals in students with pre-exam anxiety.
Association of auricular pressing and heart rate variability in pre-exam anxiety students
Wu, Wocao; Chen, Junqi; Zhen, Erchuan; Huang, Huanlin; Zhang, Pei; Wang, Jiao; Ou, Yingyi; Huang, Yong
2013-01-01
A total of 30 students scoring between 12 and 20 on the Test Anxiety Scale who had been exhibiting an anxious state > 24 hours, and 30 normal control students were recruited. Indices of heart rate variability were recorded using an Actiheart electrocardiogram recorder at 10 minutes before auricular pressing, in the first half of stimulation and in the second half of stimulation. The results revealed that the standard deviation of all normal to normal intervals and the root mean square of standard deviation of normal to normal intervals were significantly increased after stimulation. The heart rate variability triangular index, very-low-frequency power, low-frequency power, and the ratio of low-frequency to high-frequency power were increased to different degrees after stimulation. Compared with normal controls, the root mean square of standard deviation of normal to normal intervals was significantly increased in anxious students following auricular pressing. These results indicated that auricular pressing can elevate heart rate variability, especially the root mean square of standard deviation of normal to normal intervals in students with pre-exam anxiety. PMID:25206734
Offshore fatigue design turbulence
NASA Astrophysics Data System (ADS)
Larsen, Gunner C.
2001-07-01
Fatigue damage on wind turbines is mainly caused by stochastic loading originating from turbulence. While onshore sites display large differences in terrain topology, and thereby also in turbulence conditions, offshore sites are far more homogeneous, as the majority of them are likely to be associated with shallow water areas. However, despite this fact, specific recommendations on offshore turbulence intensities, applicable for fatigue design purposes, are lacking in the present IEC code. This article presents specific guidelines for such loading. These guidelines are based on the statistical analysis of a large number of wind data originating from two Danish shallow water offshore sites. The turbulence standard deviation depends on the mean wind speed, upstream conditions, measuring height and thermal convection. Defining a population of turbulence standard deviations, at a given measuring position, uniquely by the mean wind speed, variations in upstream conditions and atmospheric stability will appear as variability of the turbulence standard deviation. Distributions of such turbulence standard deviations, conditioned on the mean wind speed, are quantified by fitting the measured data to logarithmic Gaussian distributions. By combining a simple heuristic load model with the parametrized conditional probability density functions of the turbulence standard deviations, an empirical offshore design turbulence intensity is determined. For pure stochastic loading (as associated with standstill situations), the design turbulence intensity yields a fatigue damage equal to the average fatigue damage caused by the distributed turbulence intensity. If the stochastic loading is combined with a periodic deterministic loading (as in the normal operating situation), the proposed design turbulence intensity is shown to be conservative.
Estimating extreme stream temperatures by the standard deviate method
NASA Astrophysics Data System (ADS)
Bogan, Travis; Othmer, Jonathan; Mohseni, Omid; Stefan, Heinz
2006-02-01
It is now widely accepted that global climate warming is taking place on the earth. Among many other effects, a rise in air temperatures is expected to increase stream temperatures indefinitely. However, due to evaporative cooling, stream temperatures do not increase linearly with increasing air temperatures indefinitely. Within the anticipated bounds of climate warming, extreme stream temperatures may therefore not rise substantially. With this concept in mind, past extreme temperatures measured at 720 USGS stream gauging stations were analyzed by the standard deviate method. In this method the highest stream temperatures are expressed as the mean temperature of a measured partial maximum stream temperature series plus its standard deviation multiplied by a factor KE (standard deviate). Various KE-values were explored; values of KE larger than 8 were found physically unreasonable. It is concluded that the value of KE should be in the range from 7 to 8. A unit error in estimating KE translates into a typical stream temperature error of about 0.5 °C. Using a logistic model for the stream temperature/air temperature relationship, a one degree error in air temperature gives a typical error of 0.16 °C in stream temperature. With a projected error in the enveloping standard deviate dKE=1.0 (range 0.5-1.5) and an error in projected high air temperature d Ta=2 °C (range 0-4 °C), the total projected stream temperature error is estimated as d Ts=0.8 °C.
NASA Technical Reports Server (NTRS)
Rhoads, James E.; Rigby, Jane Rebecca; Malhotra, Sangeeta; Allam, Sahar; Carilli, Chris; Combes, Francoise; Finkelstein, Keely; Finkelstein, Steven; Frye, Brenda; Gerin, Maryvonne;
2014-01-01
We report on two regularly rotating galaxies at redshift z approx. = 2, using high-resolution spectra of the bright [C microns] 158 micrometers emission line from the HIFI instrument on the Herschel Space Observatory. Both SDSS090122.37+181432.3 ("S0901") and SDSSJ120602.09+514229.5 ("the Clone") are strongly lensed and show the double-horned line profile that is typical of rotating gas disks. Using a parametric disk model to fit the emission line profiles, we find that S0901 has a rotation speed of v sin(i) approx. = 120 +/- 7 kms(sup -1) and a gas velocity dispersion of (standard deviation)g < 23 km s(sup -1) (1(standard deviation)). The best-fitting model for the Clone is a rotationally supported disk having v sin(i) approx. = 79 +/- 11 km s(sup -1) and (standard deviation)g 4 kms(sup -1) (1(standard deviation)). However, the Clone is also consistent with a family of dispersion-dominated models having (standard deviation)g = 92 +/- 20 km s(sup -1). Our results showcase the potential of the [C microns] line as a kinematic probe of high-redshift galaxy dynamics: [C microns] is bright, accessible to heterodyne receivers with exquisite velocity resolution, and traces dense star-forming interstellar gas. Future [C microns] line observations with ALMA would offer the further advantage of spatial resolution, allowing a clearer separation between rotation and velocity dispersion.
Reliability of the Dutch translation of the Kujala Patellofemoral Score Questionnaire.
Ummels, P E J; Lenssen, A F; Barendrecht, M; Beurskens, A J H M
2017-01-01
There are no Dutch language disease-specific questionnaires for patients with patellofemoral pain syndrome available that could help Dutch physiotherapists to assess and monitor these symptoms and functional limitations. The aim of this study was to translate the original disease-specific Kujala Patellofemoral Score into Dutch and evaluate its reliability. The questionnaire was translated from English into Dutch in accordance with internationally recommended guidelines. Reliability was determined in 50 stable subjects with an interval of 1 week. The patient inclusion criteria were age between 14 and 60 years; knowledge of the Dutch language; and the presence of at least three of the following symptoms: pain while taking the stairs, pain when squatting, pain when running, pain when cycling, pain when sitting with knees flexed for a prolonged period, grinding of the patella and a positive clinical patella test. The internal consistency, test-retest reliability, measurement error and limits of agreement were calculated. Internal consistency was 0.78 for the first assessment and 0.80 for the second assessment. The intraclass correlation coefficient (ICC agreement ) between the first and second assessments was 0.98. The mean difference between the first and second measurements was 0.64, and standard deviation was 5.51. The standard error measurement was 3.9, and the smallest detectable change was 11. The Bland and Altman plot shows that the limits of agreement are -10.37 and 11.65. The results of the present study indicated that the test-retest reliability translated Dutch version of the Kujala Patellofemoral Score questionnaire is equivalent of the test-retest original English language version and has good internal consistency. Trial registration NTR (TC = 3258). Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
Yan, H C; Hao, Y T; Guo, Y F; Wei, Y H; Zhang, J H; Huang, G P; Mao, L M; Zhang, Z Q
2017-11-10
Objective: To evaluate the accuracy of simple anthropometric parameters in diagnosing obesity in children in Guangzhou. Methods: A cross-sectional study, including 465 children aged 6-9 years, was carried out in Guangzhou. Their body height and weight, waist circumference (WC) and hip circumference were measured according to standard procedure. Body mass index (BMI), waist to hip ratio (WHR) and waist-to-height ratio (WHtR) were calculated. Body fat percentage (BF%) was determined by dual-energy X-ray absorptiometry. Multiple regression analysis was applied to evaluate the correlations between age-adjusted physical indicators and BF%, after the adjustment for age. Obesity was defined by BF%. Receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic accuracy of the indicators for childhood obesity. Area under-ROC curves (AUCs) were calculated and the best cut-off point that maximizing 'sensitivity + specificity-1' was determined. Results: BMI showed the strongest association with BF% through multiple regression analysis. For 'per-standard deviation increase' of BMI, BF% increased by 5.3% ( t =23.1, P <0.01) in boys and 4.6% ( t =17.5, P <0.01) in girls, respectively. The ROC curve analysis indicated that BMI exhibited the largest AUC in both boys (AUC=0.908) and girls (AUC=0.895). The sensitivity was 80.8% in boys and 81.8% in girls, and the specificity was 88.2% in boys and 87.1% in girls. Both the AUCs for WHtR and WC were less than 0.8 in boys and girls. WHR had the smallest AUCs (<0.8) in both boys and girls. Conclusion: BMI appeared to be a good predicator for BF% in children aged 6-9 years in Guangzhou.
NASA Astrophysics Data System (ADS)
Ramm, D. J.
2015-06-01
We explore the possibly that either star-spots or pulsations are the cause of a periodic radial velocity (RV) signal (P ˜ 400 d) from the K-giant binary ν Octantis (P ˜ 1050 d, e ˜ 0.25), alternatively conjectured to have a retrograde planet. Our study is based on temperatures derived from 22 line-depth ratios (LDRs) for ν Oct and 20 calibration stars. Empirical evidence and stability modelling provide unexpected support for the planet since other standard explanations (star-spots, pulsations and additional stellar masses) each have credibility problems. However, the proposed system presents formidable challenges to planet formation and stability theories: it has by far the smallest stellar separation of any claimed planet-harbouring binary (a_{_bin} ˜ 2.6 au) and an equally unbelievable separation ratio (a_{_pl}/a_{_bin} ˜ 0.5), hence the necessity that the circumstellar orbit be retrograde. The LDR analysis of 215 ν Oct spectra acquired between 2001 and 2007, from which the RV perturbation was first revealed, have no significant periodicity at any frequency. The LDRs recover the original 21 stellar temperatures with an average accuracy of 45 ± 25 K. The 215 ν Oct temperatures have a standard deviation of only 4.2 K. Assuming the host primary is not pulsating, the temperatures converted to magnitude differences strikingly mimic the very stable photometric Hipparcos observations 15 years previously, implying the long-term stability of the star and demonstrating a novel use of LDRs as a photometric gauge. Our results provide substantial new evidence that conventional star-spots and pulsations are unlikely causes of the RV perturbation. The controversial system deserves continued attention, including with higher resolving-power spectra for bisector and LDR analyses.
Fink, A; Gebhard, B; Erdwiens, S; Haddenhorst, L; Nowak, S
2016-09-01
The introduction of the International Classification of Functioning, Disabilities and Health of the World Health Organization in 2001 made social participation a major rehabilitation outcome and the ultimate goal of rehabilitation services. There is no available instrument to measure the youth participation in leisure activities apart from asking the youth themselves. The goal of this study was to present a German version of the Children's Assessment of Participation and Enjoyment and Preferences for Activities of Children (CAPE/PAC). The CAPE/PAC questionnaire was translated into German, a cultural adaptation process was designed and a reliability study was conducted. One hundred and fifty-two youths with and without disabilities, with a mean age of 15.2 years (standard deviation 1.7), participated in the study. The participants completed CAPE and PAC twice within 4 weeks. Reliability was examined by intraclass correlation coefficients, standard error of measurement, smallest detectable change and Cronbach's alpha. The absolute values of participation differ between the typically developed youth group and those with impairments; the reliability of the CAPE/PAC is comparable in both groups. Intraclass correlation coefficients ranged from 0.43 to 0.74 for the CAPE and from 0.71 to 0.83 for the PAC in all participants. The alpha values for internal consistency ranged from 0.42 to 0.82 for the CAPE and from 0.65 to 0.92 for the PAC. The German version of the PAC showed satisfactory reliability; however, reliability was not satisfactory for all scores of the CAPE, but comparable with versions in other languages. The need for newly developed participation measurements requires further discussion. © 2016 John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fried, D; Meier, J; Mawlawi, O
Purpose: Use a NEMA-IEC PET phantom to assess the robustness of FDG-PET-based radiomics features to changes in reconstruction parameters across different scanners. Methods: We scanned a NEMA-IEC PET phantom on 3 different scanners (GE Discovery VCT, GE Discovery 710, and Siemens mCT) using a FDG source-to-background ratio of 10:1. Images were retrospectively reconstructed using different iterations (2–3), subsets (21–24), Gaussian filter widths (2, 4, 6mm), and matrix sizes (128,192,256). The 710 and mCT used time-of-flight and point-spread-functions in reconstruction. The axial-image through the center of the 6 active spheres was used for analysis. A region-of-interest containing all spheres was ablemore » to simulate a heterogeneous lesion due to partial volume effects. Maximum voxel deviations from all retrospectively reconstructed images (18 per scanner) was compared to our standard clinical protocol. PET Images from 195 non-small cell lung cancer patients were used to compare feature variation. The ratio of a feature’s standard deviation from the patient cohort versus the phantom images was calculated to assess for feature robustness. Results: Across all images, the percentage of voxels differing by <1SUV and <2SUV ranged from 61–92% and 88–99%, respectively. Voxel-voxel similarity decreased when using higher resolution image matrices (192/256 versus 128) and was comparable across scanners. Taking the ratio of patient and phantom feature standard deviation was able to identify features that were not robust to changes in reconstruction parameters (e.g. co-occurrence correlation). Metrics found to be reasonably robust (standard deviation ratios > 3) were observed for routinely used SUV metrics (e.g. SUVmean and SUVmax) as well as some radiomics features (e.g. co-occurrence contrast, co-occurrence energy, standard deviation, and uniformity). Similar standard deviation ratios were observed across scanners. Conclusions: Our method enabled a comparison of feature variability across scanners and was able to identify features that were not robust to changes in reconstruction parameters.« less
NASA Astrophysics Data System (ADS)
Stier, P.; Schutgens, N. A. J.; Bian, H.; Boucher, O.; Chin, M.; Ghan, S.; Huneeus, N.; Kinne, S.; Lin, G.; Myhre, G.; Penner, J. E.; Randles, C.; Samset, B.; Schulz, M.; Yu, H.; Zhou, C.
2012-09-01
Simulated multi-model "diversity" in aerosol direct radiative forcing estimates is often perceived as measure of aerosol uncertainty. However, current models used for aerosol radiative forcing calculations vary considerably in model components relevant for forcing calculations and the associated "host-model uncertainties" are generally convoluted with the actual aerosol uncertainty. In this AeroCom Prescribed intercomparison study we systematically isolate and quantify host model uncertainties on aerosol forcing experiments through prescription of identical aerosol radiative properties in nine participating models. Even with prescribed aerosol radiative properties, simulated clear-sky and all-sky aerosol radiative forcings show significant diversity. For a purely scattering case with globally constant optical depth of 0.2, the global-mean all-sky top-of-atmosphere radiative forcing is -4.51 W m-2 and the inter-model standard deviation is 0.70 W m-2, corresponding to a relative standard deviation of 15%. For a case with partially absorbing aerosol with an aerosol optical depth of 0.2 and single scattering albedo of 0.8, the forcing changes to 1.26 W m-2, and the standard deviation increases to 1.21 W m-2, corresponding to a significant relative standard deviation of 96%. However, the top-of-atmosphere forcing variability owing to absorption is low, with relative standard deviations of 9% clear-sky and 12% all-sky. Scaling the forcing standard deviation for a purely scattering case to match the sulfate radiative forcing in the AeroCom Direct Effect experiment, demonstrates that host model uncertainties could explain about half of the overall sulfate forcing diversity of 0.13 W m-2 in the AeroCom Direct Radiative Effect experiment. Host model errors in aerosol radiative forcing are largest in regions of uncertain host model components, such as stratocumulus cloud decks or areas with poorly constrained surface albedos, such as sea ice. Our results demonstrate that host model uncertainties are an important component of aerosol forcing uncertainty that require further attention.
Robust Alternatives to the Standard Deviation in Processing of Physics Experimental Data
NASA Astrophysics Data System (ADS)
Shulenin, V. P.
2016-10-01
Properties of robust estimations of the scale parameter are studied. It is noted that the median of absolute deviations and the modified estimation of the average Gini differences have asymptotically normal distributions and bounded influence functions, are B-robust estimations, and hence, unlike the estimation of the standard deviation, are protected from the presence of outliers in the sample. Results of comparison of estimations of the scale parameter are given for a Gaussian model with contamination. An adaptive variant of the modified estimation of the average Gini differences is considered.
40 CFR 63.7751 - What reports must I submit and when?
Code of Federal Regulations, 2010 CFR
2010-07-01
... deviations from any emissions limitations (including operating limit), work practice standards, or operation and maintenance requirements, a statement that there were no deviations from the emissions limitations...-of-control during the reporting period. (7) For each deviation from an emissions limitation...
Lockie, Robert G; Schultz, Adrian B; Callaghan, Samuel J; Jeffriess, Matthew D; Berry, Simon P
2013-01-01
Field sport coaches must use reliable and valid tests to assess change-of-direction speed in their athletes. Few tests feature linear sprinting with acute change- of-direction maneuvers. The Change-of-Direction and Acceleration Test (CODAT) was designed to assess field sport change-of-direction speed, and includes a linear 5-meter (m) sprint, 45° and 90° cuts, 3- m sprints to the left and right, and a linear 10-m sprint. This study analyzed the reliability and validity of this test, through comparisons to 20-m sprint (0-5, 0-10, 0-20 m intervals) and Illinois agility run (IAR) performance. Eighteen Australian footballers (age = 23.83 ± 7.04 yrs; height = 1.79 ± 0.06 m; mass = 85.36 ± 13.21 kg) were recruited. Following familiarization, subjects completed the 20-m sprint, CODAT, and IAR in 2 sessions, 48 hours apart. Intra-class correlation coefficients (ICC) assessed relative reliability. Absolute reliability was analyzed through paired samples t-tests (p ≤ 0.05) determining between-session differences. Typical error (TE), coefficient of variation (CV), and differences between the TE and smallest worthwhile change (SWC), also assessed absolute reliability and test usefulness. For the validity analysis, Pearson's correlations (p ≤ 0.05) analyzed between-test relationships. Results showed no between-session differences for any test (p = 0.19-0.86). CODAT time averaged ~6 s, and the ICC and CV equaled 0.84 and 3.0%, respectively. The homogeneous sample of Australian footballers meant that the CODAT's TE (0.19 s) exceeded the usual 0.2 x standard deviation (SD) SWC (0.10 s). However, the CODAT is capable of detecting moderate performance changes (SWC calculated as 0.5 x SD = 0.25 s). There was a near perfect correlation between the CODAT and IAR (r = 0.92), and very large correlations with the 20-m sprint (r = 0.75-0.76), suggesting that the CODAT was a valid change-of-direction speed test. Due to movement specificity, the CODAT has value for field sport assessment. Key pointsThe change-of-direction and acceleration test (CODAT) was designed specifically for field sport athletes from specific speed research, and data derived from time-motion analyses of sports such as rugby union, soccer, and Australian football. The CODAT features a linear 5-meter (m) sprint, 45° and 90° cuts and 3-m sprints to the left and right, and a linear 10-m sprint.The CODAT was found to be a reliable change-of-direction speed assessment when considering intra-class correlations between two testing sessions, and the coefficient of variation between trials. A homogeneous sample of Australian footballers resulted in absolute reliability limitations when considering differences between the typical error and smallest worthwhile change. However, the CODAT will detect moderate (0.5 times the test's standard deviation) changes in performance.The CODAT correlated with the Illinois agility run, highlighting that it does assess change-of-direction speed. There were also significant relationships with short sprint performance (i.e. 0-5 m and 0-10 m), demonstrating that linear acceleration is assessed within the CODAT, without the extended duration and therefore metabolic limitations of the IAR. Indeed, the average duration of the test (~6 seconds) is field sport-specific. Therefore, the CODAT could be used as an assessment of change-of-direction speed in field sport athletes.
Use of Standard Deviations as Predictors in Models Using Large-Scale International Data Sets
ERIC Educational Resources Information Center
Austin, Bruce; French, Brian; Adesope, Olusola; Gotch, Chad
2017-01-01
Measures of variability are successfully used in predictive modeling in research areas outside of education. This study examined how standard deviations can be used to address research questions not easily addressed using traditional measures such as group means based on index variables. Student survey data were obtained from the Organisation for…
Screen Twice, Cut Once: Assessing the Predictive Validity of Teacher Selection Tools
ERIC Educational Resources Information Center
Goldhaber, Dan; Grout, Cyrus; Huntington-Klein, Nick
2015-01-01
It is well documented that teachers can have profound effects on student outcomes. Empirical estimates find that a one standard deviation increase in teacher quality raises student test achievement by 10 to 25 percent of a standard deviation. More recent evidence shows that the effectiveness of teachers can affect long-term student outcomes, such…
Comparing Measurement Error between Two Different Methods of Measurement of Various Magnitudes
ERIC Educational Resources Information Center
Zavorsky, Gerald S.
2010-01-01
Measurement error is a common problem in several fields of research such as medicine, physiology, and exercise science. The standard deviation of repeated measurements on the same person is the measurement error. One way of presenting measurement error is called the repeatability, which is 2.77 multiplied by the within subject standard deviation.…
Parabolic trough receiver heat loss and optical efficiency round robin 2015/2016
NASA Astrophysics Data System (ADS)
Pernpeintner, Johannes; Schiricke, Björn; Sallaberry, Fabienne; de Jalón, Alberto García; López-Martín, Rafael; Valenzuela, Loreto; de Luca, Antonio; Georg, Andreas
2017-06-01
A round robin for parabolic trough receiver heat loss and optical efficiency in the laboratory was performed between five institutions using five receivers in 2015/2016. Heat loss testing was performed at three cartridge heater test benches and one Joule heating test bench in the temperature range between 100 °C and 550 °C. Optical efficiency testing was performed with two spectrometric test bench and one calorimetric test bench. Heat loss testing results showed standard deviations at the order of 6% to 12 % for most temperatures and receivers and a standard deviation of 17 % for one receiver at 100 °C. Optical efficiency is presented normalized for laboratories showing standard deviations of 0.3 % to 1.3 % depending on the receiver.
Benign positional vertigo and hyperuricaemia.
Adam, A M
2005-07-01
To find out if there is any association between serum uric acid level and positional vertigo. A prospective, case controlled study. A private neurological clinic. All patients presenting with vertigo. Ninety patients were seen in this period with 78 males and 19 females. Mean age was 47 +/- 3 years (at 95% confidence level) with a standard deviation of 12.4. Their mean uric acid level was 442 +/- 16 (at 95% confidence level) with a standard deviation of 79.6 umol/l as compared to 291 +/- 17 (at 95% confidence level) with a standard deviation of 79.7 umol/l in the control group. The P-value was less than 0.001. That there is a significant association between high uric acid and benign positional vertigo.
NASA Technical Reports Server (NTRS)
Clark, P. E.; Andre, C. G.; Adler, I.; Weidner, J.; Podwysocki, M.
1976-01-01
The positive correlation between Al/Si X-ray fluorescence intensity ratios determined during the Apollo 15 lunar mission and a broad-spectrum visible albedo of the moon is quantitatively established. Linear regression analysis performed on 246 1 degree geographic cells of X-ray fluorescence intensity and visible albedo data points produced a statistically significant correlation coefficient of .78. Three distinct distributions of data were identified as (1) within one standard deviation of the regression line, (2) greater than one standard deviation below the line, and (3) greater than one standard deviation above the line. The latter two distributions of data were found to occupy distinct geographic areas in the Palus Somni region.
Screening Samples for Arsenic by Inductively Coupled Plasma-Mass Spectrometry for Treaty Samples
2014-02-01
2.274 3.657 10.06 14.56 30.36 35.93 % RSD : 15.87% 4.375% 2.931% 4.473% 3.349% 3.788% 2.802% 3.883% 3.449% RSD , relative standard deviation 9 Table...107.9% 106.4% Standard Deviation: 0.3171 0.3498 0.8024 2.964 4.526 10.06 13.83 16.38 11.81 % RSD : 5.657% 3.174% 3.035% 5.507% 4.332% 3.795% 2.626...119.1% 116.5% 109.4% 106.8% 105.2% 105.5% 105.8% 108.6% 107.8% Standard Deviation: 0.2379 0.5595 1.173 2.375 2.798 5.973 11.79 15.10 30.54 % RSD
A deviation display method for visualising data in mobile gamma-ray spectrometry.
Kock, Peder; Finck, Robert R; Nilsson, Jonas M C; Ostlund, Karl; Samuelsson, Christer
2010-09-01
A real time visualisation method, to be used in mobile gamma-spectrometric search operations using standard detector systems is presented. The new method, called deviation display, uses a modified waterfall display to present relative changes in spectral data over energy and time. Using unshielded (137)Cs and (241)Am point sources and different natural background environments, the behaviour of the deviation displays is demonstrated and analysed for two standard detector types (NaI(Tl) and HPGe). The deviation display enhances positive significant changes while suppressing the natural background fluctuations. After an initialization time of about 10min this technique leads to a homogeneous display dominated by the background colour, where even small changes in spectral data are easy to discover. As this paper shows, the deviation display method works well for all tested gamma energies and natural background radiation levels and with both tested detector systems.
Castro-Sánchez, Adelaida María; Matarán-Peñarrocha, Guillermo A; Sánchez-Labraca, Nuria; Quesada-Rubio, José Manuel; Granero-Molina, José; Moreno-Lorenzo, Carmen
2011-01-01
Fibromyalgia is a prevalent musculoskeletal disorder associated with widespread mechanical tenderness, fatigue, non-refreshing sleep, depressed mood and pervasive dysfunction of the autonomic nervous system: tachycardia, postural intolerance, Raynaud's phenomenon and diarrhoea. To determine the effects of craniosacral therapy on sensitive tender points and heart rate variability in patients with fibromyalgia. A randomized controlled trial. Ninety-two patients with fibromyalgia were randomly assigned to an intervention group or placebo group. Patients received treatments for 20 weeks. The intervention group underwent a craniosacral therapy protocol and the placebo group received sham treatment with disconnected magnetotherapy equipment. Pain intensity levels were determined by evaluating tender points, and heart rate variability was recorded by 24-hour Holter monitoring. After 20 weeks of treatment, the intervention group showed significant reduction in pain at 13 of the 18 tender points (P < 0.05). Significant differences in temporal standard deviation of RR segments, root mean square deviation of temporal standard deviation of RR segments and clinical global impression of improvement versus baseline values were observed in the intervention group but not in the placebo group. At two months and one year post therapy, the intervention group showed significant differences versus baseline in tender points at left occiput, left-side lower cervical, left epicondyle and left greater trochanter and significant differences in temporal standard deviation of RR segments, root mean square deviation of temporal standard deviation of RR segments and clinical global impression of improvement. Craniosacral therapy improved medium-term pain symptoms in patients with fibromyalgia.
Code of Federal Regulations, 2010 CFR
2010-07-01
... which are distinct from the standard deviation process and specific to the requirements of the Federal... agency request a deviation from the provisions of this part? 102-38.30 Section 102-38.30 Public Contracts... executive agency request a deviation from the provisions of this part? Refer to §§ 102-2.60 through 102-2...
Considering dominance in reduced single-step genomic evaluations.
Ertl, J; Edel, C; Pimentel, E C G; Emmerling, R; Götz, K-U
2018-06-01
Single-step models including dominance can be an enormous computational task and can even be prohibitive for practical application. In this study, we try to answer the question whether a reduced single-step model is able to estimate breeding values of bulls and breeding values, dominance deviations and total genetic values of cows with acceptable quality. Genetic values and phenotypes were simulated (500 repetitions) for a small Fleckvieh pedigree consisting of 371 bulls (180 thereof genotyped) and 553 cows (40 thereof genotyped). This pedigree was virtually extended for 2,407 non-genotyped daughters. Genetic values were estimated with the single-step model and with different reduced single-step models. Including more relatives of genotyped cows in the reduced single-step model resulted in a better agreement of results with the single-step model. Accuracies of genetic values were largest with single-step and smallest with reduced single-step when only the cows genotyped were modelled. The results indicate that a reduced single-step model is suitable to estimate breeding values of bulls and breeding values, dominance deviations and total genetic values of cows with acceptable quality. © 2018 Blackwell Verlag GmbH.
Family structure and childhood anthropometry in Saint Paul, Minnesota in 1918
Warren, John Robert
2017-01-01
Concern with childhood nutrition prompted numerous surveys of children’s growth in the United States after 1870. The Children’s Bureau’s 1918 “Weighing and Measuring Test” measured two million children to produce the first official American growth norms. Individual data for 14,000 children survives from the Saint Paul, Minnesota survey whose stature closely approximated national norms. As well as anthropometry the survey recorded exact ages, street address and full name. These variables allow linkage to the 1920 census to obtain demographic and socioeconomic information. We matched 72% of children to census families creating a sample of nearly 10,000 children. Children in the entire survey (linked set) averaged 0.74 (0.72) standard deviations below modern WHO height-for-age standards, and 0.48 (0.46) standard deviations below modern weight-for-age norms. Sibship size strongly influenced height-for-age, and had weaker influence on weight-for-age. Each additional child six or underreduced height-for-age scores by 0.07 standard deviations (95% CI: −0.03, 0.11). Teenage siblings had little effect on height-forage. Social class effects were substantial. Children of laborers averaged half a standard deviation shorter than children of professionals. Family structure and socio-economic status had compounding impacts on children’s stature. PMID:28943749
9 CFR 113.455 - Clostridium Perfringens Type D Antitoxin.
Code of Federal Regulations, 2011 CFR
2011-01-01
... cause sickness or death in injected mice. (iii) L + dose. The smallest quantity of toxin which can be mixed with one-tenth unit of Standard Antitoxin and cause death in at least 80 percent of injected mice... until injections of mice can be made. (vi) Five Swiss white mice, each weighing 16-20 grams, shall be...
Physics on the Smallest Scales: An Introduction to Minimal Length Phenomenology
ERIC Educational Resources Information Center
Sprenger, Martin; Nicolini, Piero; Bleicher, Marcus
2012-01-01
Many modern theories which try to unify gravity with the Standard Model of particle physics, such as e.g. string theory, propose two key modifications to the commonly known physical theories: the existence of additional space dimensions; the existence of a minimal length distance or maximal resolution. While extra dimensions have received a wide…
NASA Technical Reports Server (NTRS)
Spera, David A.
2008-01-01
Equations are developed with which to calculate lift and drag coefficients along the spans of torsionally-stiff rotating airfoils of the type used in wind turbine rotors and wind tunnel fans, at angles of attack in both the unstalled and stalled aerodynamic regimes. Explicit adjustments are made for the effects of aspect ratio (length to chord width) and airfoil thickness ratio. Calculated lift and drag parameters are compared to measured parameters for 55 airfoil data sets including 585 test points. Mean deviation was found to be -0.4 percent and standard deviation was 4.8 percent. When the proposed equations were applied to the calculation of power from a stall-controlled wind turbine tested in a NASA wind tunnel, mean deviation from 54 data points was -1.3 percent and standard deviation was 4.0 percent. Pressure-rise calculations for a large wind tunnel fan deviated by 2.7 percent (mean) and 4.4 percent (standard). The assumption that a single set of lift and drag coefficient equations can represent the stalled aerodynamic behavior of a wide variety of airfoils was found to be satisfactory.
Seay, Joseph F.; Gregorczyk, Karen N.; Hasselquist, Leif
2016-01-01
Abstract Influences of load carriage and inclination on spatiotemporal parameters were examined during treadmill and overground walking. Ten soldiers walked on a treadmill and overground with three load conditions (00 kg, 20 kg, 40 kg) during level, uphill (6% grade) and downhill (-6% grade) inclinations at self-selected speed, which was constant across conditions. Mean values and standard deviations for double support percentage, stride length and a step rate were compared across conditions. Double support percentage increased with load and inclination change from uphill to level walking, with a 0.4% stance greater increase at the 20 kg condition compared to 00 kg. As inclination changed from uphill to downhill, the step rate increased more overground (4.3 ± 3.5 steps/min) than during treadmill walking (1.7 ± 2.3 steps/min). For the 40 kg condition, the standard deviations were larger than the 00 kg condition for both the step rate and double support percentage. There was no change between modes for step rate standard deviation. For overground compared to treadmill walking, standard deviation for stride length and double support percentage increased and decreased, respectively. Changes in the load of up to 40 kg, inclination of 6% grade away from the level (i.e., uphill or downhill) and mode (treadmill and overground) produced small, yet statistically significant changes in spatiotemporal parameters. Variability, as assessed by standard deviation, was not systematically lower during treadmill walking compared to overground walking. Due to the small magnitude of changes, treadmill walking appears to replicate the spatiotemporal parameters of overground walking. PMID:28149338
Hopper, John L
2015-11-15
How can the "strengths" of risk factors, in the sense of how well they discriminate cases from controls, be compared when they are measured on different scales such as continuous, binary, and integer? Given that risk estimates take into account other fitted and design-related factors-and that is how risk gradients are interpreted-so should the presentation of risk gradients. Therefore, for each risk factor X0, I propose using appropriate regression techniques to derive from appropriate population data the best fitting relationship between the mean of X0 and all the other covariates fitted in the model or adjusted for by design (X1, X2, … , Xn). The odds per adjusted standard deviation (OPERA) presents the risk association for X0 in terms of the change in risk per s = standard deviation of X0 adjusted for X1, X2, … , Xn, rather than the unadjusted standard deviation of X0 itself. If the increased risk is relative risk (RR)-fold over A adjusted standard deviations, then OPERA = exp[ln(RR)/A] = RR(s). This unifying approach is illustrated by considering breast cancer and published risk estimates. OPERA estimates are by definition independent and can be used to compare the predictive strengths of risk factors across diseases and populations. © The Author 2015. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Maassen, Gerard H
2010-08-01
In this Journal, Lewis and colleagues introduced a new Reliable Change Index (RCI(WSD)), which incorporated the within-subject standard deviation (WSD) of a repeated measurement design as the standard error. In this note, two opposite errors in using WSD this way are demonstrated. First, being the standard error of measurement of only a single assessment makes WSD too small when practice effects are absent. Then, too many individuals will be designated reliably changed. Second, WSD can grow unlimitedly to the extent that differential practice effects occur. This can even make RCI(WSD) unable to detect any reliable change.
Gender Differences in Numeracy in Indonesia: Evidence from a Longitudinal Dataset
ERIC Educational Resources Information Center
Suryadarma, Daniel
2015-01-01
This paper uses a rich longitudinal dataset to measure the evolution of the gender differences in numeracy among school-age children in Indonesia. Girls outperformed boys by 0.08 standard deviations when the sample was around 11 years old. Seven years later, the gap has widened to 0.19 standard deviations, equivalent to around 18 months of…
A Survey Data Response to the Teaching of Utility Curves and Risk Aversion
ERIC Educational Resources Information Center
Hobbs, Jeffrey; Sharma, Vivek
2011-01-01
In many finance and economics courses as well as in practice, the concept of risk aversion is reduced to the standard deviation of returns, whereby risk-averse investors prefer to minimize their portfolios' standard deviations. In reality, the concept of risk aversion is richer and more interesting than this, and can easily be conveyed through…
On the Linear Relation between the Mean and the Standard Deviation of a Response Time Distribution
ERIC Educational Resources Information Center
Wagenmakers, Eric-Jan; Brown, Scott
2007-01-01
Although it is generally accepted that the spread of a response time (RT) distribution increases with the mean, the precise nature of this relation remains relatively unexplored. The authors show that in several descriptive RT distributions, the standard deviation increases linearly with the mean. Results from a wide range of tasks from different…
Yarazavi, Mina; Noroozian, Ebrahim
2018-02-13
A novel sol-gel coating on a stainless-steel fiber was developed for the first time for the headspace solid-phase microextraction and determination of α-bisabolol with gas chromatography and flame ionization detection. The parameters influencing the efficiency of solid-phase microextraction process, such as extraction time and temperature, pH, and ionic strength, were optimized by the experimental design method. Under optimized conditions, the linear range was between 0.0027 and 100 μg/mL. The relative standard deviations determined at 0.01 and 1.0 μg/mL concentration levels (n = 3), respectively, were as follows: intraday relative standard deviations 3.4 and 3.3%; interday relative standard deviations 5.0 and 4.3%; and fiber-to-fiber relative standard deviations 6.0 and 3.5%. The relative recovery values were 90.3 and 101.4% at 0.01 and 1.0 μg/mL spiking levels, respectively. The proposed method was successfully applied to various real samples containing α-bisabolol. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Weigel, Stefan; Peters, Ruud; Loeschner, Katrin; Grombe, Ringo; Linsinger, Thomas P J
2017-08-01
Single-particle inductively coupled plasma mass spectrometry (sp-ICP-MS) promises fast and selective determination of nanoparticle size and number concentrations. While several studies on practical applications have been published, data on formal, especially interlaboratory validation of sp-ICP-MS, is sparse. An international interlaboratory study was organized to determine repeatability and reproducibility of the determination of the median particle size and particle number concentration of Ag nanoparticles (AgNPs) in chicken meat. Ten laboratories from the European Union, the USA, and Canada determined particle size and particle number concentration of two chicken meat homogenates spiked with polyvinylpyrrolidone (PVP)-stabilized AgNPs. For the determination of the median particle diameter, repeatability standard deviations of 2 and 5% were determined, and reproducibility standard deviations were 15 and 25%, respectively. The equivalent median diameter itself was approximately 60% larger than the diameter of the particles in the spiking solution. Determination of the particle number concentration was significantly less precise, with repeatability standard deviations of 7 and 18% and reproducibility standard deviations of 70 and 90%.
Estimation of Tooth Size Discrepancies among Different Malocclusion Groups
Bala, Madhu; Goyal, Virender
2014-01-01
ABSTRACT Regards and Tribute: Late Dr Narender Hasija was a mentor and visionary in the light of knowledge and experience. We pay our regards with deepest gratitude to the departed soul to rest in peace. Bolton’s ratios help in estimating overbite, overjet relationships, the effects of contemplated extractions on posterior occlusion, incisor relationships and identification of occlusal misfit produced by tooth size discrepancies. Aim: To determine any difference in tooth size discrepancy in anterior as well as overall ratio in different malocclusions and comparison with Bolton’s study. Materials and methods: After measuring the teeth on all 100 patients, Bolton’s analysis was performed. Results were compared with Bolton’s means and standard deviations. The results were also subjected to statistical analysis. Results show that the mean and standard deviations of ideal occlusion cases are comparable with those Bolton but, when the mean and standard deviation of malocclusion groups are compared with those of Bolton, the values of standard deviation are higher, though the mean is comparable. How to cite this article: Hasija N, Bala M, Goyal V. Estimation of Tooth Size Discrepancies among Different Malocclusion Groups. Int J Clin Pediatr Dent 2014;7(2):82-85. PMID:25356005
McKenna, D; Kadidlo, D; Sumstad, D; McCullough, J
2003-01-01
Errors and accidents, or deviations from standard operating procedures, other policy, or regulations must be documented and reviewed, with corrective actions taken to assure quality performance in a cellular therapy laboratory. Though expectations and guidance for deviation management exist, a description of the framework for the development of such a program is lacking in the literature. Here we describe our deviation management program, which uses a Microsoft Access database and Microsoft Excel to analyze deviations and notable events, facilitating quality assurance (QA) functions and ongoing process improvement. Data is stored in a Microsoft Access database with an assignment to one of six deviation type categories. Deviation events are evaluated for potential impact on patient and product, and impact scores for each are determined using a 0- 4 grading scale. An immediate investigation occurs, and corrective actions are taken to prevent future similar events from taking place. Additionally, deviation data is collectively analyzed on a quarterly basis using Microsoft Excel, to identify recurring events or developing trends. Between January 1, 2001 and December 31, 2001 over 2500 products were processed at our laboratory. During this time period, 335 deviations and notable events occurred, affecting 385 products and/or patients. Deviations within the 'technical error' category were most common (37%). Thirteen percent of deviations had a patient and/or a product impact score > or = 2, a score indicating, at a minimum, potentially affected patient outcome or moderate effect upon product quality. Real-time analysis and quarterly review of deviations using our deviation management program allows for identification and correction of deviations. Monitoring of deviation trends allows for process improvement and overall successful functioning of the QA program in the cell therapy laboratory. Our deviation management program could serve as a model for other laboratories in need of such a program.
NASA Astrophysics Data System (ADS)
Briggs, M.; Lautz, L. K.; McKenzie, J. M.
2010-12-01
Small dams enhance hyporheic interaction by creating punctuated head differentials along streams, thereby affecting redox conditions and nutrient cycling in the streambed. As beaver populations return, they create dams that alter hyporheic flowpaths locally, an effect which may integrate at the reach scale to produce a net hydrological and ecological functional change. Streambed heterogeneity around beaver dams combines with varied morphology, head differentials and stream velocities to create patterns of hyporheic seepage flux that vary in both space and time. Heat has been used as a groundwater tracer for many years, but it’s dependence on spatially disperse point measurements has only recently been resolved by the development of Distributed Temperature Sensing (DTS) fiber-optic technology. Modified applications of DTS include wrapping the fiber around a mandrel to increase spatial resolution dramatically. Wrapped configurations can be installed vertically in the streambed to provide data for heat transport modeling of vertical hyporheic flux. The vertically continuous dataset generated with DTS may be more informative regarding subsurface heterogeneity than more commonly used spatially discrete thermocouples. We installed a total of nine wrapped DTS rods with 1.4 cm vertical spatial resolution above two beaver dams in Cherry Creek, a tributary of the Little Popo Agie River in Lander, Wyoming, USA. Data was collected over 20 min periods in dual-ended mode continuously for one month (10-Jul to 10-Aug 2010) during baseflow recession, as discharge dropped from 384 Ls-1 to 211 Ls-1. The temperature rods were installed to at least 0.75 m depth within bed sediments at varied distances upstream of the dams in diverse stream morphological units, which ranged from gravel bars to clay lined pools. Diurnal fluctuations in stream temperature were generally between 4.5 and 5.5 oC in amplitude, imparting a strong potential signal for propagation into the bed due to advective hyporheic flux. In many locations monthly temperature standard deviations at the 10 cm depth were larger than that of the overlying stream water, indicating direct heating of the streambed by solar radiation was an important process, even in that high velocity system. The high-resolution temperature records revealed local heterogeneity in the streambed at each rod and indicated the largest hyporheic flux was within gravel bars close to the dams. The smallest flux was through a gravel bar farther upstream of the dam, and through the deepest portions of pools closer to the dam. High flux regions had monthly temperature standard deviations close to that of the stream (1.5 oC) at shallow depths, while shallow sediments in pools had much more muted temperature oscillations. At 0.5 m depth, all rods had similar, smaller temperature standard deviations, ranging from 0.64-0.80 oC. The extensive and spatially continuous data set generated using DTS allowed us to determine hyporheic flux patterns for virtually any depth and time along the high-resolution temperature rods, a crucial step for understanding transient patterns in biogeochemical processing around beaver dams.
NASA Technical Reports Server (NTRS)
Selle, Laurent C.; Bellan, Josette
2006-01-01
A model of multicomponent-liquid (MC-liquid) drop evaporation in a three-dimensional mixing layer is here exercised at larger Reynolds numbers than in a previous study, and transitional states are obtained. The gas phase is followed in an Eulerian frame and the multitude of drops is described in a Lagrangian frame. Complete coupling between phases is included with source terms in the gas conservation equations accounting for the drop/flow interaction in terms of drop drag, drop heating and species evaporation. The liquid composition, initially specified as a single-Gamma (SG) probability distribution function (PDF) depending on the molar mass is allowed to evolve into a linear combination of two SGPDFs, called the double-Gamma PDF (DGPDF). The compositions of liquid and vapor emanating from the drops are calculated through four moments of the DGPDFs, which are drop-specific and location-specific, respectively. The mixing layer is initially excited to promote the double pairing of its four initial spanwise vortices into an ultimate vortex in which small scales proliferate. Simulations are performed for four liquids of different compositions and the effect of the initial mass loading and initial free-stream gas temperature are explored. For reference, Simulations are also performed for gaseous multicomponent mixing layers for which the effect of Reynolds number is investigated. The results encompass examination of the global layer characteristics, flow visualizations and homogeneous-plane statistics at transition. Comparisons are performed with previous pre-transitional MC-liquid simulations and with transitional single-component (SC) liquid studies. It is found that MCC flows at transition, the classical energy cascade is of similar strength, but that the smallest scales contain orders of magnitude less energy than SC flows, which is confirmed by the larger viscous dissipation in the former case. Contrasting to pre-transitional MC flows, the vorticity and drop organization depend on the initial gas temperature, this being due to the drop/turbulence coupling. The vapor-composition mean molar mass and standard deviation distributions strongly correlate with the initial liquid-composition PDF; such a correlation only exists for the magnitude of the mean but not for that of the standard deviation. Unlike in pre-transitional situations, regions of large composition standard deviation no longer necessarily coincide with regions of large mean molar mass. The kinetic energy, rotational and composition characteristics, and dissipation are liquid specific and the variation among liquids is amplified with increasing free-stream gas temperature. Eulerian and Lagrangian statistics of gas-phase quantities show that the different. Observation framework may affect the perception of the flow characteristics. The gas composition, of which the first four moments are calculated, is shown to be close to, but distinct from a SGPDF. The PDF of the scalar dissipation rate is calculated for drop-laden layers and is shown to depart more significantly from the typically assumed Gaussian in gaseous flows than experimentally measured gaseous scalar dissipation rates, this being attributed to the increased heterogeneity due to drop/flow interactions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gomez-Cardona, Daniel; Nagle, Scott K.; Department of Radiology, University of Wisconsin-Madison School of Medicine and Public Health, 600 Highland Avenue, Madison, Wisconsin 53792
Purpose: Wall thickness (WT) is an airway feature of great interest for the assessment of morphological changes in the lung parenchyma. Multidetector computed tomography (MDCT) has recently been used to evaluate airway WT, but the potential risk of radiation-induced carcinogenesis—particularly in younger patients—might limit a wider use of this imaging method in clinical practice. The recent commercial implementation of the statistical model-based iterative reconstruction (MBIR) algorithm, instead of the conventional filtered back projection (FBP) algorithm, has enabled considerable radiation dose reduction in many other clinical applications of MDCT. The purpose of this work was to study the impact of radiationmore » dose and MBIR in the MDCT assessment of airway WT. Methods: An airway phantom was scanned using a clinical MDCT system (Discovery CT750 HD, GE Healthcare) at 4 kV levels and 5 mAs levels. Both FBP and a commercial implementation of MBIR (Veo{sup TM}, GE Healthcare) were used to reconstruct CT images of the airways. For each kV–mAs combination and each reconstruction algorithm, the contrast-to-noise ratio (CNR) of the airways was measured, and the WT of each airway was measured and compared with the nominal value; the relative bias and the angular standard deviation in the measured WT were calculated. For each airway and reconstruction algorithm, the overall performance of WT quantification across all of the 20 kV–mAs combinations was quantified by the sum of squares (SSQs) of the difference between the measured and nominal WT values. Finally, the particular kV–mAs combination and reconstruction algorithm that minimized radiation dose while still achieving a reference WT quantification accuracy level was chosen as the optimal acquisition and reconstruction settings. Results: The wall thicknesses of seven airways of different sizes were analyzed in the study. Compared with FBP, MBIR improved the CNR of the airways, particularly at low radiation dose levels. For FBP, the relative bias and the angular standard deviation of the measured WT increased steeply with decreasing radiation dose. Except for the smallest airway, MBIR enabled significant reduction in both the relative bias and angular standard deviation of the WT, particularly at low radiation dose levels; the SSQ was reduced by 50%–96% by using MBIR. The optimal reconstruction algorithm was found to be MBIR for the seven airways being assessed, and the combined use of MBIR and optimal kV–mAs selection resulted in a radiation dose reduction of 37%–83% compared with a reference scan protocol with a dose level of 1 mGy. Conclusions: The quantification accuracy of airway WT is strongly influenced by radiation dose and reconstruction algorithm. The MBIR algorithm potentially allows the desired WT quantification accuracy to be achieved with reduced radiation dose, which may enable a wider clinical use of MDCT for the assessment of airway WT, particularly for younger patients who may be more sensitive to exposures with ionizing radiation.« less
Analyzing Spatial and Temporal Variation in Precipitation Estimates in a Coupled Model
NASA Astrophysics Data System (ADS)
Tomkins, C. D.; Springer, E. P.; Costigan, K. R.
2001-12-01
Integrated modeling efforts at the Los Alamos National Laboratory aim to simulate the hydrologic cycle and study the impacts of climate variability and land use changes on water resources and ecosystem function at the regional scale. The integrated model couples three existing models independently responsible for addressing the atmospheric, land surface, and ground water components: the Regional Atmospheric Model System (RAMS), the Los Alamos Distributed Hydrologic System (LADHS), and the Finite Element and Heat Mass (FEHM). The upper Rio Grande Basin, extending 92,000 km2 over northern New Mexico and southern Colorado, serves as the test site for this model. RAMS uses nested grids to simulate meteorological variables, with the smallest grid over the Rio Grande having 5-km horizontal grid spacing. As LADHS grid spacing is 100 m, a downscaling approach is needed to estimate meteorological variables from the 5km RAMS grid for input into LADHS. This study presents daily and cumulative precipitation predictions, in the month of October for water year 1993, and an approach to compare LADHS downscaled precipitation to RAMS-simulated precipitation. The downscaling algorithm is based on kriging, using topography as a covariate to distribute the precipitation and thereby incorporating the topographical resolution achieved at the 100m-grid resolution in LADHS. The results of the downscaling are analyzed in terms of the level of variance introduced into the model, mean simulated precipitation, and the correlation between the LADHS and RAMS estimates. Previous work presented a comparison of RAMS-simulated and observed precipitation recorded at COOP and SNOTEL sites. The effects of downscaling the RAMS precipitation were evaluated using Spearman and linear correlations and by examining the variance of both populations. The study focuses on determining how the downscaling changes the distribution of precipitation compared to the RAMS estimates. Spearman correlations computed for the LADHS and RAMS cumulative precipitation reveal a disassociation over time, with R equal to 0.74 at day eight and R equal to 0.52 at day 31. Linear correlation coefficients (Pearson) returned a stronger initial correlation of 0.97, decreasing to 0.68. The standard deviations for the 2500 LADHS cells underlying each 5km RAMS cell range from 8 mm to 695 mm in the Sangre de Cristo Mountains and 2 mm to 112 mm in the San Luis Valley. Comparatively, the standard deviations of the RAMS estimates in these regions are 247 mm and 30 mm respectively. The LADHS standard deviations provide a measure of the variability introduced through the downscaling routine, which exceeds RAMS regional variability by a factor of 2 to 4. The coefficient of variation for the average LADHS grid cell values and the RAMS cell values in the Sangre de Cristo Mountains are 0.66 and 0.27, respectively, and 0.79 and 0.75 in the San Luis Valley. The coefficients of variation evidence the uniformity of the higher precipitation estimates in the mountains, especially for RAMS, and also the lower means and variability found in the valley. Additionally, Kolmogorov-Smirnov tests indicate clear spatial and temporal differences in mean simulated precipitation across the grid.
Flow Cytometry of Human Primary Epidermal and Follicular Keratinocytes
Gragnani, Alfredo; Ipolito, Michelle Zampieri; Sobral, Christiane S; Brunialti, Milena Karina Coló; Salomão, Reinaldo; Ferreira, Lydia Masako
2008-01-01
Objective: The aim of this study was to characterize using flow cytometry cultured human primary keratinocytes isolated from the epidermis and hair follicles by different methods. Methods: Human keratinocytes derived from discarded fragments of total skin and scalp hair follicles from patients who underwent plastic surgery in the Plastic Surgery Division at UNIFESP were used. The epidermal keratinocytes were isolated by using 3 different methods: the standard method, upon exposure to trypsin for 30 minutes; the second, by treatment with dispase for 18 hours and with trypsin for 10 minutes; and the third, by treatment with dispase for 18 hours and with trypsin for 30 minutes. Follicular keratinocytes were isolated using the standard method. Results: On comparing the group treated with dispase for 18 hours and with trypsin for 10 minutes with the group treated with dispase for 18 hours and with trypsin for 30 minutes, it was observed that the first group presented the largest number of viable cells, the smallest number of cells in late apoptosis and necrosis with statistical significance, and no difference in apoptosis. When we compared the group treated with dispase for 18 hours and with trypsin for 10 minutes with the group treated with trypsin, the first group presented the largest number of viable cells, the smallest number of cells in apoptosis with statistical significance, and no difference in late apoptosis and necrosis. When we compared the results of the group treated with dispase for 18 hours and with trypsin for 10 minutes with the results for follical isolation, there was a statistical difference in apoptosis and viable cells. Conclusion: The isolation method of treatment with dispase for 18 hours and with trypsin for 10 minutes produced the largest number of viable cells and the smallest number of cells in apoptosis/necrosis. PMID:18350110
Flow cytometry of human primary epidermal and follicular keratinocytes.
Gragnani, Alfredo; Ipolito, Michelle Zampieri; Sobral, Christiane S; Brunialti, Milena Karina Coló; Salomão, Reinaldo; Ferreira, Lydia Masako
2008-02-19
The aim of this study was to characterize using flow cytometry cultured human primary keratinocytes isolated from the epidermis and hair follicles by different methods. Human keratinocytes derived from discarded fragments of total skin and scalp hair follicles from patients who underwent plastic surgery in the Plastic Surgery Division at UNIFESP were used. The epidermal keratinocytes were isolated by using 3 different methods: the standard method, upon exposure to trypsin for 30 minutes; the second, by treatment with dispase for 18 hours and with trypsin for 10 minutes; and the third, by treatment with dispase for 18 hours and with trypsin for 30 minutes. Follicular keratinocytes were isolated using the standard method. On comparing the group treated with dispase for 18 hours and with trypsin for 10 minutes with the group treated with dispase for 18 hours and with trypsin for 30 minutes, it was observed that the first group presented the largest number of viable cells, the smallest number of cells in late apoptosis and necrosis with statistical significance, and no difference in apoptosis. When we compared the group treated with dispase for 18 hours and with trypsin for 10 minutes with the group treated with trypsin, the first group presented the largest number of viable cells, the smallest number of cells in apoptosis with statistical significance, and no difference in late apoptosis and necrosis. When we compared the results of the group treated with dispase for 18 hours and with trypsin for 10 minutes with the results for follical isolation, there was a statistical difference in apoptosis and viable cells. The isolation method of treatment with dispase for 18 hours and with trypsin for 10 minutes produced the largest number of viable cells and the smallest number of cells in apoptosis/necrosis.
Ku-band radar threshold analysis
NASA Technical Reports Server (NTRS)
Weber, C. L.; Polydoros, A.
1979-01-01
The statistics of the CFAR threshold for the Ku-band radar was determined. Exact analytical results were developed for both the mean and standard deviations in the designated search mode. The mean value is compared to the results of a previously reported simulation. The analytical results are more optimistic than the simulation results, for which no explanation is offered. The normalized standard deviation is shown to be very sensitive to signal-to-noise ratio and very insensitive to the noise correlation present in the range gates of the designated search mode. The substantial variation in the CFAR threshold is dominant at large values of SNR where the normalized standard deviation is greater than 0.3. Whether or not this significantly affects the resulting probability of detection is a matter which deserves additional attention.
Hart, John
2011-03-01
This study describes a model for statistically analyzing follow-up numeric-based chiropractic spinal assessments for an individual patient based on his or her own baseline. Ten mastoid fossa temperature differential readings (MFTD) obtained from a chiropractic patient were used in the study. The first eight readings served as baseline and were compared to post-adjustment readings. One of the two post-adjustment MFTD readings fell outside two standard deviations of the baseline mean and therefore theoretically represents improvement according to pattern analysis theory. This study showed how standard deviation analysis may be used to identify future outliers for an individual patient based on his or her own baseline data. Copyright © 2011 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.
1980-03-14
failure Sigmar (Or) in line 50, the standard deviation of the relative error of the weights Sigmap (o) in line 60, the standard deviation of the phase...200, the weight structures in the x and y coordinates Q in line 210, the probability of element failure Sigmar (Or) in line 220, the standard...NUMBER OF ELEMENTS =u;2*H 120 PRINT "Pr’obability of elemenit failure al;O 130 PRINT "Standard dtvi&t ion’ oe r.1&tive ýrror of wl; Sigmar 14 0 PRINT
Takarabe, S; Yabuuchi, H; Morishita, J
2012-06-01
To investigate the usefulness of the standard deviation of pixel values in a whole mammary glands region and the percentage of a high- density mammary glands region to a whole mammary glands region as features for classification of mammograms into four categories based on the ACR BI-RADS breast composition. We used 36 digital mediolateral oblique view mammograms (18 patients) approved by our IRB. These images were classified into the four categories of breast compositions by an experienced breast radiologist and the results of the classification were regarded as a gold standard. First, a whole mammary region in a breast was divided into two regions such as a high-density mammary glands region and a low/iso-density mammary glands region by using a threshold value that was obtained from the pixel values corresponding to a pectoral muscle region. Then the percentage of a high-density mammary glands region to a whole mammary glands region was calculated. In addition, as a new method, the standard deviation of pixel values in a whole mammary glands region was calculated as an index based on the intermingling of mammary glands and fats. Finally, all mammograms were classified by using the combination of the percentage of a high-density mammary glands region and the standard deviation of each image. The agreement rates of the classification between our proposed method and gold standard was 86% (31/36). This result signified that our method has the potential to classify mammograms. The combination of the standard deviation of pixel values in a whole mammary glands region and the percentage of a high-density mammary glands region to a whole mammary glands region was available as features to classify mammograms based on the ACR BI- RADS breast composition. © 2012 American Association of Physicists in Medicine.
40 CFR 63.7951 - What reports must I submit and when?
Code of Federal Regulations, 2010 CFR
2010-07-01
... the information in § 63.10(d)(5)(i). (5) If there were no deviations from any emissions limitations... that there were no deviations from the emissions limitations, work practice standards, or operation and...) For each deviation from an emissions limitation (including an operating limit) that occurs at an...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gupta, N; DiCostanzo, D; Fullenkamp, M
2015-06-15
Purpose: To determine appropriate couch tolerance values for modern radiotherapy linac R&V systems with indexed patient setup. Methods: Treatment table tolerance values have been the most difficult to lower, due to many factors including variations in patient positioning and differences in table tops between machines. We recently installed nine linacs with similar tables and started indexing every patient in our clinic. In this study we queried our R&V database and analyzed the deviation of couch position values from the acquired values at verification simulation for all patients treated with indexed positioning. Mean and standard deviations of daily setup deviations weremore » computed in the longitudinal, lateral and vertical direction for 343 patient plans. The mean, median and standard error of the standard deviations across the whole patient population and for some disease sites were computed to determine tolerance values. Results: The plot of our couch deviation values showed a gaussian distribution, with some small deviations, corresponding to setup uncertainties on non-imaging days, and SRS/SRT/SBRT patients, as well as some large deviations which were spot checked and found to be corresponding to indexing errors that were overriden. Setting our tolerance values based on the median + 1 standard error resulted in tolerance values of 1cm lateral and longitudinal, and 0.5 cm vertical for all non- SRS/SRT/SBRT cases. Re-analizing the data, we found that about 92% of the treated fractions would be within these tolerance values (ignoring the mis-indexed patients). We also analyzed data for disease site based subpopulations and found no difference in the tolerance values that needed to be used. Conclusion: With the use of automation, auto-setup and other workflow efficiency tools being introduced into radiotherapy workflow, it is very essential to set table tolerances that allow safe treatments, but flag setup errors that need to be reassessed before treatments.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aaboud, M.; Aad, G.; Abbott, B.
Here, a search for the associated production of the Higgs boson with a top quark pair (more » $$t\\bar{t}$$H) is reported. The search is performed in multilepton final states using a data set corresponding to an integrated luminosity of 36.1 fb -1 of proton-proton collision data recorded by the ATLAS experiment at a center-of-mass energy $$\\sqrt{s}$$ = 13 TeV at the Large Hadron Collider. Higgs boson decays to WW*, ττ, and ZZ* are targeted. Seven final states, categorized by the number and flavor of charged-lepton candidates, are examined for the presence of the Standard Model Higgs boson with a mass of 125 GeV and a pair of top quarks. An excess of events over the expected background from Standard Model processes is found with an observed significance of 4.1 standard deviations, compared to an expectation of 2.8 standard deviations. The best fit for the $$t\\bar{t}$$H production cross section is σ($$t\\bar{t}$$H) = $${790}_{-210}^{+230}$$ fb, in agreement with the Standard Model prediction of $${507}_{-50}^{+35}$$ fb. The combination of this result with other $$t\\bar{t}$$H searches from the ATLAS experiment using the Higgs boson decay modes to $$b\\bar{b}$$, γγ and ZZ* → 4ℓ, has an observed significance of 4.2 standard deviations, compared to an expectation of 3.8 standard deviations. This provides evidence for the $$t\\bar{t}$$H production mode.« less
Aaboud, M.; Aad, G.; Abbott, B.; ...
2018-04-09
Here, a search for the associated production of the Higgs boson with a top quark pair (more » $$t\\bar{t}$$H) is reported. The search is performed in multilepton final states using a data set corresponding to an integrated luminosity of 36.1 fb -1 of proton-proton collision data recorded by the ATLAS experiment at a center-of-mass energy $$\\sqrt{s}$$ = 13 TeV at the Large Hadron Collider. Higgs boson decays to WW*, ττ, and ZZ* are targeted. Seven final states, categorized by the number and flavor of charged-lepton candidates, are examined for the presence of the Standard Model Higgs boson with a mass of 125 GeV and a pair of top quarks. An excess of events over the expected background from Standard Model processes is found with an observed significance of 4.1 standard deviations, compared to an expectation of 2.8 standard deviations. The best fit for the $$t\\bar{t}$$H production cross section is σ($$t\\bar{t}$$H) = $${790}_{-210}^{+230}$$ fb, in agreement with the Standard Model prediction of $${507}_{-50}^{+35}$$ fb. The combination of this result with other $$t\\bar{t}$$H searches from the ATLAS experiment using the Higgs boson decay modes to $$b\\bar{b}$$, γγ and ZZ* → 4ℓ, has an observed significance of 4.2 standard deviations, compared to an expectation of 3.8 standard deviations. This provides evidence for the $$t\\bar{t}$$H production mode.« less
NASA Astrophysics Data System (ADS)
Aaboud, M.; Aad, G.; Abbott, B.; Abdinov, O.; Abeloos, B.; Abidi, S. H.; Abouzeid, O. S.; Abraham, N. L.; Abramowicz, H.; Abreu, H.; Abulaiti, Y.; Acharya, B. S.; Adachi, S.; Adamczyk, L.; Adelman, J.; Adersberger, M.; Adye, T.; Affolder, A. A.; Afik, Y.; Agheorghiesei, C.; Aguilar-Saavedra, J. A.; Ahlen, S. P.; Ahmadov, F.; Aielli, G.; Akatsuka, S.; Åkesson, T. P. A.; Akilli, E.; Akimov, A. V.; Alberghi, G. L.; Albert, J.; Albicocco, P.; Alconada Verzini, M. J.; Alderweireldt, S. C.; Aleksa, M.; Aleksandrov, I. N.; Alexa, C.; Alexander, G.; Alexopoulos, T.; Alhroob, M.; Ali, B.; Aliev, M.; Alimonti, G.; Alison, J.; Alkire, S. P.; Allaire, C.; Allbrooke, B. M. M.; Allen, B. W.; Allport, P. P.; Aloisio, A.; Alonso, A.; Alonso, F.; Alpigiani, C.; Alshehri, A. A.; Alstaty, M. I.; Alvarez Gonzalez, B.; Álvarez Piqueras, D.; Alviggi, M. G.; Amadio, B. T.; Amaral Coutinho, Y.; Ambroz, L.; Amelung, C.; Amidei, D.; Amor Dos Santos, S. P.; Amoroso, S.; Anastopoulos, C.; Ancu, L. S.; Andari, N.; Andeen, T.; Anders, C. F.; Anders, J. K.; Anderson, K. J.; Andreazza, A.; Andrei, V.; Angelidakis, S.; Angelozzi, I.; Angerami, A.; Anisenkov, A. V.; Annovi, A.; Antel, C.; Antonelli, M.; Antonov, A.; Antrim, D. J.; Anulli, F.; Aoki, M.; Aperio Bella, L.; Arabidze, G.; Arai, Y.; Araque, J. P.; Araujo Ferraz, V.; Arce, A. T. H.; Ardell, R. E.; Arduh, F. A.; Arguin, J.-F.; Argyropoulos, S.; Armbruster, A. J.; Armitage, L. J.; Arnaez, O.; Arnold, H.; Arratia, M.; Arslan, O.; Artamonov, A.; Artoni, G.; Artz, S.; Asai, S.; Asbah, N.; Ashkenazi, A.; Asquith, L.; Assamagan, K.; Astalos, R.; Atkin, R. J.; Atkinson, M.; Atlay, N. B.; Augsten, K.; Avolio, G.; Avramidou, R.; Axen, B.; Ayoub, M. K.; Azuelos, G.; Baas, A. E.; Baca, M. J.; Bachacou, H.; Bachas, K.; Backes, M.; Bagnaia, P.; Bahmani, M.; Bahrasemani, H.; Baines, J. T.; Bajic, M.; Baker, O. K.; Bakker, P. J.; Bakshi Gupta, D.; Baldin, E. M.; Balek, P.; Balli, F.; Balunas, W. K.; Banas, E.; Bandyopadhyay, A.; Banerjee, Sw.; Bannoura, A. A. E.; Barak, L.; Barberio, E. L.; Barberis, D.; Barbero, M.; Barillari, T.; Barisits, M.-S.; Barkeloo, J. T.; Barklow, T.; Barlow, N.; Barnea, R.; Barnes, S. L.; Barnett, B. M.; Barnett, R. M.; Barnovska-Blenessy, Z.; Baroncelli, A.; Barone, G.; Barr, A. J.; Barranco Navarro, L.; Barreiro, F.; Barreiro Guimarães da Costa, J.; Bartoldus, R.; Barton, A. E.; Bartos, P.; Basalaev, A.; Bassalat, A.; Bates, R. L.; Batista, S. J.; Batley, J. R.; Battaglia, M.; Bauce, M.; Bauer, F.; Bauer, K. T.; Bawa, H. S.; Beacham, J. B.; Beattie, M. D.; Beau, T.; Beauchemin, P. H.; Bechtle, P.; Beck, H. P.; Beck, H. C.; Becker, K.; Becker, M.; Becot, C.; Beddall, A. J.; Beddall, A.; Bednyakov, V. A.; Bedognetti, M.; Bee, C. P.; Beermann, T. A.; Begalli, M.; Begel, M.; Behera, A.; Behr, J. K.; Bell, A. S.; Bella, G.; Bellagamba, L.; Bellerive, A.; Bellomo, M.; Belotskiy, K.; Belyaev, N. L.; Benary, O.; Benchekroun, D.; Bender, M.; Benekos, N.; Benhammou, Y.; Benhar Noccioli, E.; Benitez, J.; Benjamin, D. P.; Benoit, M.; Bensinger, J. R.; Bentvelsen, S.; Beresford, L.; Beretta, M.; Berge, D.; Bergeaas Kuutmann, E.; Berger, N.; Bergsten, L. J.; Beringer, J.; Berlendis, S.; Bernard, N. R.; Bernardi, G.; Bernius, C.; Bernlochner, F. U.; Berry, T.; Berta, P.; Bertella, C.; Bertoli, G.; Bertram, I. A.; Bertsche, C.; Besjes, G. J.; Bessidskaia Bylund, O.; Bessner, M.; Besson, N.; Bethani, A.; Bethke, S.; Betti, A.; Bevan, A. J.; Beyer, J.; Bianchi, R. M.; Biebel, O.; Biedermann, D.; Bielski, R.; Bierwagen, K.; Biesuz, N. V.; Biglietti, M.; Billoud, T. R. V.; Bindi, M.; Bingul, A.; Bini, C.; Biondi, S.; Bisanz, T.; Bittrich, C.; Bjergaard, D. M.; Black, J. E.; Black, K. M.; Blair, R. E.; Blazek, T.; Bloch, I.; Blocker, C.; Blue, A.; Blumenschein, U.; Blunier, Dr.; Bobbink, G. J.; Bobrovnikov, V. S.; Bocchetta, S. S.; Bocci, A.; Bock, C.; Boerner, D.; Bogavac, D.; Bogdanchikov, A. G.; Bohm, C.; Boisvert, V.; Bokan, P.; Bold, T.; Boldyrev, A. S.; Bolz, A. E.; Bomben, M.; Bona, M.; Bonilla, J. S.; Boonekamp, M.; Borisov, A.; Borissov, G.; Bortfeldt, J.; Bortoletto, D.; Bortolotto, V.; Boscherini, D.; Bosman, M.; Bossio Sola, J. D.; Boudreau, J.; Bouhova-Thacker, E. V.; Boumediene, D.; Bourdarios, C.; Boutle, S. K.; Boveia, A.; Boyd, J.; Boyko, I. R.; Bozson, A. J.; Bracinik, J.; Brandt, A.; Brandt, G.; Brandt, O.; Braren, F.; Bratzler, U.; Brau, B.; Brau, J. E.; Breaden Madden, W. D.; Brendlinger, K.; Brennan, A. J.; Brenner, L.; Brenner, R.; Bressler, S.; Briglin, D. L.; Bristow, T. M.; Britton, D.; Britzger, D.; Brock, I.; Brock, R.; Brooijmans, G.; Brooks, T.; Brooks, W. K.; Brost, E.; Broughton, J. H.; Bruckman de Renstrom, P. A.; Bruncko, D.; Bruni, A.; Bruni, G.; Bruni, L. S.; Bruno, S.; Brunt, Bh; Bruschi, M.; Bruscino, N.; Bryant, P.; Bryngemark, L.; Buanes, T.; Buat, Q.; Buchholz, P.; Buckley, A. G.; Budagov, I. A.; Buehrer, F.; Bugge, M. K.; Bulekov, O.; Bullock, D.; Burch, T. J.; Burdin, S.; Burgard, C. D.; Burger, A. M.; Burghgrave, B.; Burka, K.; Burke, S.; Burmeister, I.; Burr, J. T. P.; Büscher, D.; Büscher, V.; Buschmann, E.; Bussey, P.; Butler, J. M.; Buttar, C. M.; Butterworth, J. M.; Butti, P.; Buttinger, W.; Buzatu, A.; Buzykaev, A. R.; Cabras, G.; Cabrera Urbán, S.; Caforio, D.; Cai, H.; Cairo, V. M. M.; Cakir, O.; Calace, N.; Calafiura, P.; Calandri, A.; Calderini, G.; Calfayan, P.; Callea, G.; Caloba, L. P.; Calvente Lopez, S.; Calvet, D.; Calvet, S.; Calvet, T. P.; Camacho Toro, R.; Camarda, S.; Camarri, P.; Cameron, D.; Caminal Armadans, R.; Camincher, C.; Campana, S.; Campanelli, M.; Camplani, A.; Campoverde, A.; Canale, V.; Cano Bret, M.; Cantero, J.; Cao, T.; Capeans Garrido, M. D. M.; Caprini, I.; Caprini, M.; Capua, M.; Carbone, R. M.; Cardarelli, R.; Cardillo, F.; Carli, I.; Carli, T.; Carlino, G.; Carlson, B. T.; Carminati, L.; Carney, R. M. D.; Caron, S.; Carquin, E.; Carrá, S.; Carrillo-Montoya, G. D.; Casadei, D.; Casado, M. P.; Casha, A. F.; Casolino, M.; Casper, D. W.; Castelijn, R.; Castillo Gimenez, V.; Castro, N. F.; Catinaccio, A.; Catmore, J. R.; Cattai, A.; Caudron, J.; Cavaliere, V.; Cavallaro, E.; Cavalli, D.; Cavalli-Sforza, M.; Cavasinni, V.; Celebi, E.; Ceradini, F.; Cerda Alberich, L.; Cerqueira, A. S.; Cerri, A.; Cerrito, L.; Cerutti, F.; Cervelli, A.; Cetin, S. A.; Chafaq, A.; Chakraborty, D.; Chan, S. K.; Chan, W. S.; Chan, Y. L.; Chang, P.; Chapman, J. D.; Charlton, D. G.; Chau, C. C.; Chavez Barajas, C. A.; Che, S.; Chegwidden, A.; Chekanov, S.; Chekulaev, S. V.; Chelkov, G. A.; Chelstowska, M. A.; Chen, C.; Chen, C.; Chen, H.; Chen, J.; Chen, J.; Chen, S.; Chen, S.; Chen, X.; Chen, Y.; Cheng, H. C.; Cheng, H. J.; Cheplakov, A.; Cheremushkina, E.; Cherkaoui El Moursli, R.; Cheu, E.; Cheung, K.; Chevalier, L.; Chiarella, V.; Chiarelli, G.; Chiodini, G.; Chisholm, A. S.; Chitan, A.; Chiu, Y. H.; Chizhov, M. V.; Choi, K.; Chomont, A. R.; Chouridou, S.; Chow, Y. S.; Christodoulou, V.; Chu, M. C.; Chudoba, J.; Chuinard, A. J.; Chwastowski, J. J.; Chytka, L.; Cinca, D.; Cindro, V.; Cioarǎ, I. A.; Ciocio, A.; Cirotto, F.; Citron, Z. H.; Citterio, M.; Clark, A.; Clark, M. R.; Clark, P. J.; Clarke, R. N.; Clement, C.; Coadou, Y.; Cobal, M.; Coccaro, A.; Cochran, J.; Colasurdo, L.; Cole, B.; Colijn, A. P.; Collot, J.; Conde Muiño, P.; Coniavitis, E.; Connell, S. H.; Connelly, I. A.; Constantinescu, S.; Conti, G.; Conventi, F.; Cooper-Sarkar, A. M.; Cormier, F.; Cormier, K. J. R.; Corradi, M.; Corrigan, E. E.; Corriveau, F.; Cortes-Gonzalez, A.; Costa, M. J.; Costanzo, D.; Cottin, G.; Cowan, G.; Cox, B. E.; Cranmer, K.; Crawley, S. J.; Creager, R. A.; Cree, G.; Crépé-Renaudin, S.; Crescioli, F.; Cristinziani, M.; Croft, V.; Crosetti, G.; Cueto, A.; Cuhadar Donszelmann, T.; Cukierman, A. R.; Cummings, J.; Curatolo, M.; Cúth, J.; Czekierda, S.; Czodrowski, P.; D'Amen, G.; D'Auria, S.; D'Eramo, L.; D'Onofrio, M.; da Cunha Sargedas de Sousa, M. J.; da Via, C.; Dabrowski, W.; Dado, T.; Dahbi, S.; Dai, T.; Dale, O.; Dallaire, F.; Dallapiccola, C.; Dam, M.; Dandoy, J. R.; Daneri, M. F.; Dang, N. P.; Dann, N. S.; Danninger, M.; Dano Hoffmann, M.; Dao, V.; Darbo, G.; Darmora, S.; Dattagupta, A.; Daubney, T.; Davey, W.; David, C.; Davidek, T.; Davis, D. R.; Davison, P.; Dawe, E.; Dawson, I.; de, K.; de Asmundis, R.; de Benedetti, A.; de Castro, S.; de Cecco, S.; de Groot, N.; de Jong, P.; de la Torre, H.; de Lorenzi, F.; de Maria, A.; de Pedis, D.; de Salvo, A.; de Sanctis, U.; de Santo, A.; de Vasconcelos Corga, K.; de Vivie de Regie, J. B.; Debenedetti, C.; Dedovich, D. V.; Dehghanian, N.; Deigaard, I.; Del Gaudio, M.; Del Peso, J.; Delgove, D.; Deliot, F.; Delitzsch, C. M.; Dell'Acqua, A.; Dell'Asta, L.; Della Pietra, M.; Della Volpe, D.; Delmastro, M.; Delporte, C.; Delsart, P. A.; Demarco, D. A.; Demers, S.; Demichev, M.; Denisov, S. P.; Denysiuk, D.; Derendarz, D.; Derkaoui, J. E.; Derue, F.; Dervan, P.; Desch, K.; Deterre, C.; Dette, K.; Devesa, M. R.; Deviveiros, P. O.; Dewhurst, A.; Dhaliwal, S.; di Bello, F. A.; di Ciaccio, A.; di Ciaccio, L.; di Clemente, W. K.; di Donato, C.; di Girolamo, A.; di Micco, B.; di Nardo, R.; di Petrillo, K. F.; di Simone, A.; di Sipio, R.; di Valentino, D.; Diaconu, C.; Diamond, M.; Dias, F. A.; Diaz, M. A.; Dickinson, J.; Diehl, E. B.; Dietrich, J.; Díez Cornell, S.; Dimitrievska, A.; Dingfelder, J.; Dita, P.; Dita, S.; Dittus, F.; Djama, F.; Djobava, T.; Djuvsland, J. I.; Do Vale, M. A. B.; Dobre, M.; Dodsworth, D.; Doglioni, C.; Dolejsi, J.; Dolezal, Z.; Donadelli, M.; Donati, S.; Donini, J.; Dopke, J.; Doria, A.; Dova, M. T.; Doyle, A. T.; Drechsler, E.; Dreyer, E.; Dris, M.; Du, Y.; Duarte-Campderros, J.; Dubinin, F.; Dubreuil, A.; Duchovni, E.; Duckeck, G.; Ducourthial, A.; Ducu, O. A.; Duda, D.; Dudarev, A.; Dudder, A. Chr.; Duffield, E. M.; Duflot, L.; Dührssen, M.; Dulsen, C.; Dumancic, M.; Dumitriu, A. E.; Duncan, A. K.; Dunford, M.; Duperrin, A.; Duran Yildiz, H.; Düren, M.; Durglishvili, A.; Duschinger, D.; Dutta, B.; Duvnjak, D.; Dyndal, M.; Dziedzic, B. S.; Eckardt, C.; Ecker, K. M.; Edgar, R. C.; Eifert, T.; Eigen, G.; Einsweiler, K.; Ekelof, T.; El Kacimi, M.; El Kosseifi, R.; Ellajosyula, V.; Ellert, M.; Ellinghaus, F.; Elliot, A. A.; Ellis, N.; Elmsheuser, J.; Elsing, M.; Emeliyanov, D.; Enari, Y.; Ennis, J. S.; Epland, M. B.; Erdmann, J.; Ereditato, A.; Errede, S.; Escalier, M.; Escobar, C.; Esposito, B.; Estrada Pastor, O.; Etienvre, A. I.; Etzion, E.; Evans, H.; Ezhilov, A.; Ezzi, M.; Fabbri, F.; Fabbri, L.; Fabiani, V.; Facini, G.; Fakhrutdinov, R. M.; Falciano, S.; Faltova, J.; Fang, Y.; Fanti, M.; Farbin, A.; Farilla, A.; Farina, E. M.; Farooque, T.; Farrell, S.; Farrington, S. M.; Farthouat, P.; Fassi, F.; Fassnacht, P.; Fassouliotis, D.; Faucci Giannelli, M.; Favareto, A.; Fawcett, W. J.; Fayard, L.; Fedin, O. L.; Fedorko, W.; Feickert, M.; Feigl, S.; Feligioni, L.; Feng, C.; Feng, E. J.; Feng, M.; Fenton, M. J.; Fenyuk, A. B.; Feremenga, L.; Fernandez Martinez, P.; Ferrando, J.; Ferrari, A.; Ferrari, P.; Ferrari, R.; Ferreira de Lima, D. E.; Ferrer, A.; Ferrere, D.; Ferretti, C.; Fiedler, F.; Filipčič, A.; Filthaut, F.; Fincke-Keeler, M.; Finelli, K. D.; Fiolhais, M. C. N.; Fiorini, L.; Fischer, C.; Fischer, J.; Fisher, W. C.; Flaschel, N.; Fleck, I.; Fleischmann, P.; Fletcher, R. R. M.; Flick, T.; Flierl, B. M.; Flores, L. M.; Flores Castillo, L. R.; Fomin, N.; Forcolin, G. T.; Formica, A.; Förster, F. A.; Forti, A.; Foster, A. G.; Fournier, D.; Fox, H.; Fracchia, S.; Francavilla, P.; Franchini, M.; Franchino, S.; Francis, D.; Franconi, L.; Franklin, M.; Frate, M.; Fraternali, M.; Freeborn, D.; Fressard-Batraneanu, S. M.; Freund, B.; Freund, W. S.; Froidevaux, D.; Frost, J. A.; Fukunaga, C.; Fusayasu, T.; Fuster, J.; Gabizon, O.; Gabrielli, A.; Gabrielli, A.; Gach, G. P.; Gadatsch, S.; Gadomski, S.; Gagliardi, G.; Gagnon, L. G.; Galea, C.; Galhardo, B.; Gallas, E. J.; Gallop, B. J.; Gallus, P.; Galster, G.; Gan, K. K.; Ganguly, S.; Gao, Y.; Gao, Y. S.; Garay Walls, F. M.; García, C.; García Navarro, J. E.; García Pascual, J. A.; Garcia-Sciveres, M.; Gardner, R. W.; Garelli, N.; Garonne, V.; Gasnikova, K.; Gaudiello, A.; Gaudio, G.; Gavrilenko, I. L.; Gay, C.; Gaycken, G.; Gazis, E. N.; Gee, C. N. P.; Geisen, J.; Geisen, M.; Geisler, M. P.; Gellerstedt, K.; Gemme, C.; Genest, M. H.; Geng, C.; Gentile, S.; Gentsos, C.; George, S.; Gerbaudo, D.; Geßner, G.; Ghasemi, S.; Ghneimat, M.; Giacobbe, B.; Giagu, S.; Giangiacomi, N.; Giannetti, P.; Gibson, S. M.; Gignac, M.; Gilchriese, M.; Gillberg, D.; Gilles, G.; Gingrich, D. M.; Giordani, M. P.; Giorgi, F. M.; Giraud, P. F.; Giromini, P.; Giugliarelli, G.; Giugni, D.; Giuli, F.; Giulini, M.; Gkaitatzis, S.; Gkialas, I.; Gkougkousis, E. L.; Gkountoumis, P.; Gladilin, L. K.; Glasman, C.; Glatzer, J.; Glaysher, P. C. F.; Glazov, A.; Goblirsch-Kolb, M.; Godlewski, J.; Goldfarb, S.; Golling, T.; Golubkov, D.; Gomes, A.; Gonçalo, R.; Goncalves Gama, R.; Gonella, G.; Gonella, L.; Gongadze, A.; Gonnella, F.; Gonski, J. L.; González de La Hoz, S.; Gonzalez-Sevilla, S.; Goossens, L.; Gorbounov, P. A.; Gordon, H. A.; Gorini, B.; Gorini, E.; Gorišek, A.; Goshaw, A. T.; Gössling, C.; Gostkin, M. I.; Gottardo, C. A.; Goudet, C. R.; Goujdami, D.; Goussiou, A. G.; Govender, N.; Goy, C.; Gozani, E.; Grabowska-Bold, I.; Gradin, P. O. J.; Graham, E. C.; Gramling, J.; Gramstad, E.; Grancagnolo, S.; Gratchev, V.; Gravila, P. M.; Gray, C.; Gray, H. M.; Greenwood, Z. D.; Grefe, C.; Gregersen, K.; Gregor, I. M.; Grenier, P.; Grevtsov, K.; Griffiths, J.; Grillo, A. A.; Grimm, K.; Grinstein, S.; Gris, Ph.; Grivaz, J.-F.; Groh, S.; Gross, E.; Grosse-Knetter, J.; Grossi, G. C.; Grout, Z. J.; Grummer, A.; Guan, L.; Guan, W.; Guenther, J.; Guerguichon, A.; Guescini, F.; Guest, D.; Gueta, O.; Gugel, R.; Gui, B.; Guillemin, T.; Guindon, S.; Gul, U.; Gumpert, C.; Guo, J.; Guo, W.; Guo, Y.; Gupta, R.; Gurbuz, S.; Gustavino, G.; Gutelman, B. J.; Gutierrez, P.; Gutierrez Ortiz, N. G.; Gutschow, C.; Guyot, C.; Guzik, M. P.; Gwenlan, C.; Gwilliam, C. B.; Haas, A.; Haber, C.; Hadavand, H. K.; Haddad, N.; Hadef, A.; Hageböck, S.; Hagihara, M.; Hakobyan, H.; Haleem, M.; Haley, J.; Halladjian, G.; Hallewell, G. D.; Hamacher, K.; Hamal, P.; Hamano, K.; Hamilton, A.; Hamity, G. N.; Han, K.; Han, L.; Han, S.; Hanagaki, K.; Hance, M.; Handl, D. M.; Haney, B.; Hankache, R.; Hanke, P.; Hansen, E.; Hansen, J. B.; Hansen, J. D.; Hansen, M. C.; Hansen, P. H.; Hara, K.; Hard, A. S.; Harenberg, T.; Harkusha, S.; Harrison, P. F.; Hartmann, N. M.; Hasegawa, Y.; Hasib, A.; Hassani, S.; Haug, S.; Hauser, R.; Hauswald, L.; Havener, L. B.; Havranek, M.; Hawkes, C. M.; Hawkings, R. J.; Hayden, D.; Hays, C. P.; Hays, J. M.; Hayward, H. S.; Haywood, S. J.; Heck, T.; Hedberg, V.; Heelan, L.; Heer, S.; Heidegger, K. K.; Heim, S.; Heim, T.; Heinemann, B.; Heinrich, J. J.; Heinrich, L.; Heinz, C.; Hejbal, J.; Helary, L.; Held, A.; Hellman, S.; Helsens, C.; Henderson, R. C. W.; Heng, Y.; Henkelmann, S.; Henriques Correia, A. M.; Herbert, G. H.; Herde, H.; Herget, V.; Hernández Jiménez, Y.; Herr, H.; Herten, G.; Hertenberger, R.; Hervas, L.; Herwig, T. C.; Hesketh, G. G.; Hessey, N. P.; Hetherly, J. W.; Higashino, S.; Higón-Rodriguez, E.; Hildebrand, K.; Hill, E.; Hill, J. C.; Hiller, K. H.; Hillier, S. J.; Hils, M.; Hinchliffe, I.; Hirose, M.; Hirschbuehl, D.; Hiti, B.; Hladik, O.; Hlaluku, D. R.; Hoad, X.; Hobbs, J.; Hod, N.; Hodgkinson, M. C.; Hoecker, A.; Hoeferkamp, M. R.; Hoenig, F.; Hohn, D.; Hohov, D.; Holmes, T. R.; Holzbock, M.; Homann, M.; Honda, S.; Honda, T.; Hong, T. M.; Hooberman, B. H.; Hopkins, W. H.; Horii, Y.; Horton, A. J.; Horyn, L. A.; Hostachy, J.-Y.; Hostiuc, A.; Hou, S.; Hoummada, A.; Howarth, J.; Hoya, J.; Hrabovsky, M.; Hrdinka, J.; Hristova, I.; Hrivnac, J.; Hryn'ova, T.; Hrynevich, A.; Hsu, P. J.; Hsu, S.-C.; Hu, Q.; Hu, S.; Huang, Y.; Hubacek, Z.; Hubaut, F.; Huegging, F.; Huffman, T. B.; Hughes, E. W.; Huhtinen, M.; Hunter, R. F. H.; Huo, P.; Hupe, A. M.; Huseynov, N.; Huston, J.; Huth, J.; Hyneman, R.; Iacobucci, G.; Iakovidis, G.; Ibragimov, I.; Iconomidou-Fayard, L.; Idrissi, Z.; Iengo, P.; Igonkina, O.; Iguchi, R.; Iizawa, T.; Ikegami, Y.; Ikeno, M.; Iliadis, D.; Ilic, N.; Iltzsche, F.; Introzzi, G.; Iodice, M.; Iordanidou, K.; Ippolito, V.; Isacson, M. F.; Ishijima, N.; Ishino, M.; Ishitsuka, M.; Issever, C.; Istin, S.; Ito, F.; Iturbe Ponce, J. M.; Iuppa, R.; Iwasaki, H.; Izen, J. M.; Izzo, V.; Jabbar, S.; Jackson, P.; Jacobs, R. M.; Jain, V.; Jakel, G.; Jakobi, K. B.; Jakobs, K.; Jakobsen, S.; Jakoubek, T.; Jamin, D. O.; Jana, D. K.; Jansky, R.; Janssen, J.; Janus, M.; Janus, P. A.; Jarlskog, G.; Javadov, N.; Javå¯Rek, T.; Javurkova, M.; Jeanneau, F.; Jeanty, L.; Jejelava, J.; Jelinskas, A.; Jenni, P.; Jeske, C.; Jézéquel, S.; Ji, H.; Jia, J.; Jiang, H.; Jiang, Y.; Jiang, Z.; Jiggins, S.; Jimenez Pena, J.; Jin, S.; Jinaru, A.; Jinnouchi, O.; Jivan, H.; Johansson, P.; Johns, K. A.; Johnson, C. A.; Johnson, W. J.; Jon-And, K.; Jones, R. W. L.; Jones, S. D.; Jones, S.; Jones, T. J.; Jongmanns, J.; Jorge, P. M.; Jovicevic, J.; Ju, X.; Junggeburth, J. J.; Juste Rozas, A.; Kaczmarska, A.; Kado, M.; Kagan, H.; Kagan, M.; Kahn, S. J.; Kaji, T.; Kajomovitz, E.; Kalderon, C. W.; Kaluza, A.; Kama, S.; Kamenshchikov, A.; Kanjir, L.; Kano, Y.; Kantserov, V. A.; Kanzaki, J.; Kaplan, B.; Kaplan, L. S.; Kar, D.; Karakostas, K.; Karastathis, N.; Kareem, M. J.; Karentzos, E.; Karpov, S. N.; Karpova, Z. M.; Kartvelishvili, V.; Karyukhin, A. N.; Kasahara, K.; Kashif, L.; Kass, R. D.; Kastanas, A.; Kataoka, Y.; Kato, C.; Katre, A.; Katzy, J.; Kawade, K.; Kawagoe, K.; Kawamoto, T.; Kawamura, G.; Kay, E. F.; Kazanin, V. F.; Keeler, R.; Kehoe, R.; Keller, J. S.; Kellermann, E.; Kempster, J. J.; Kendrick, J.; Keoshkerian, H.; Kepka, O.; Kerševan, B. P.; Kersten, S.; Keyes, R. A.; Khader, M.; Khalil-Zada, F.; Khanov, A.; Kharlamov, A. G.; Kharlamova, T.; Khodinov, A.; Khoo, T. J.; Khovanskiy, V.; Khramov, E.; Khubua, J.; Kido, S.; Kiehn, M.; Kilby, C. R.; Kim, H. Y.; Kim, S. H.; Kim, Y. K.; Kimura, N.; Kind, O. M.; King, B. T.; Kirchmeier, D.; Kirk, J.; Kiryunin, A. E.; Kishimoto, T.; Kisielewska, D.; Kitali, V.; Kivernyk, O.; Kladiva, E.; Klapdor-Kleingrothaus, T.; Klein, M. H.; Klein, M.; Klein, U.; Kleinknecht, K.; Klimek, P.; Klimentov, A.; Klingenberg, R.; Klingl, T.; Klioutchnikova, T.; Klitzner, F. F.; Kluge, E.-E.; Kluit, P.; Kluth, S.; Kneringer, E.; Knoops, E. B. F. G.; Knue, A.; Kobayashi, A.; Kobayashi, D.; Kobayashi, T.; Kobel, M.; Kocian, M.; Kodys, P.; Koffas, T.; Koffeman, E.; Köhler, N. M.; Koi, T.; Kolb, M.; Koletsou, I.; Kondo, T.; Kondrashova, N.; Köneke, K.; König, A. C.; Kono, T.; Konoplich, R.; Konstantinidis, N.; Konya, B.; Kopeliansky, R.; Koperny, S.; Korcyl, K.; Kordas, K.; Korn, A.; Korolkov, I.; Korolkova, E. V.; Kortner, O.; Kortner, S.; Kosek, T.; Kostyukhin, V. V.; Kotwal, A.; Koulouris, A.; Kourkoumeli-Charalampidi, A.; Kourkoumelis, C.; Kourlitis, E.; Kouskoura, V.; Kowalewska, A. B.; Kowalewski, R.; Kowalski, T. Z.; Kozakai, C.; Kozanecki, W.; Kozhin, A. S.; Kramarenko, V. A.; Kramberger, G.; Krasnopevtsev, D.; Krasny, M. W.; Krasznahorkay, A.; Krauss, D.; Kremer, J. A.; Kretzschmar, J.; Kreutzfeldt, K.; Krieger, P.; Krizka, K.; Kroeninger, K.; Kroha, H.; Kroll, J.; Kroll, J.; Kroseberg, J.; Krstic, J.; Kruchonak, U.; Krüger, H.; Krumnack, N.; Kruse, M. C.; Kubota, T.; Kuday, S.; Kuechler, J. T.; Kuehn, S.; Kugel, A.; Kuger, F.; Kuhl, T.; Kukhtin, V.; Kukla, R.; Kulchitsky, Y.; Kuleshov, S.; Kulinich, Y. P.; Kuna, M.; Kunigo, T.; Kupco, A.; Kupfer, T.; Kuprash, O.; Kurashige, H.; Kurchaninov, L. L.; Kurochkin, Y. A.; Kurth, M. G.; Kuwertz, E. S.; Kuze, M.; Kvita, J.; Kwan, T.; La Rosa, A.; La Rosa Navarro, J. L.; La Rotonda, L.; La Ruffa, F.; Lacasta, C.; Lacava, F.; Lacey, J.; Lack, D. P. J.; Lacker, H.; Lacour, D.; Ladygin, E.; Lafaye, R.; Laforge, B.; Lai, S.; Lammers, S.; Lampl, W.; Lançon, E.; Landgraf, U.; Landon, M. P. J.; Lanfermann, M. C.; Lang, V. S.; Lange, J. C.; Langenberg, R. J.; Lankford, A. J.; Lanni, F.; Lantzsch, K.; Lanza, A.; Lapertosa, A.; Laplace, S.; Laporte, J. F.; Lari, T.; Lasagni Manghi, F.; Lassnig, M.; Lau, T. S.; Laudrain, A.; Law, A. T.; Laycock, P.; Lazzaroni, M.; Le, B.; Le Dortz, O.; Le Guirriec, E.; Le Quilleuc, E. P.; Leblanc, M.; Lecompte, T.; Ledroit-Guillon, F.; Lee, C. A.; Lee, G. R.; Lee, S. C.; Lee, L.; Lefebvre, B.; Lefebvre, M.; Legger, F.; Leggett, C.; Lehmann Miotto, G.; Leight, W. A.; Leisos, A.; Leite, M. A. L.; Leitner, R.; Lellouch, D.; Lemmer, B.; Leney, K. J. C.; Lenz, T.; Lenzi, B.; Leone, R.; Leone, S.; Leonidopoulos, C.; Lerner, G.; Leroy, C.; Les, R.; Lesage, A. A. J.; Lester, C. G.; Levchenko, M.; Levêque, J.; Levin, D.; Levinson, L. J.; Levy, M.; Lewis, D.; Li, B.; Li, C.-Q.; Li, H.; Li, L.; Li, Q.; Li, Q.; Li, S.; Li, X.; Li, Y.; Liang, Z.; Liberti, B.; Liblong, A.; Lie, K.; Limosani, A.; Lin, C. Y.; Lin, K.; Lin, S. C.; Lin, T. H.; Linck, R. A.; Lindquist, B. E.; Lionti, A. E.; Lipeles, E.; Lipniacka, A.; Lisovyi, M.; Liss, T. M.; Lister, A.; Litke, A. M.; Liu, B.; Liu, H.; Liu, H.; Liu, J. K. K.; Liu, J. B.; Liu, K.; Liu, M.; Liu, P.; Liu, Y. L.; Liu, Y.; Livan, M.; Lleres, A.; Llorente Merino, J.; Lloyd, S. L.; Lo, C. Y.; Lo Sterzo, F.; Lobodzinska, E. M.; Loch, P.; Loebinger, F. K.; Loesle, A.; Loew, K. M.; Lohse, T.; Lohwasser, K.; Lokajicek, M.; Long, B. A.; Long, J. D.; Long, R. E.; Longo, L.; Looper, K. A.; Lopez, J. A.; Lopez Paz, I.; Lopez Solis, A.; Lorenz, J.; Lorenzo Martinez, N.; Losada, M.; Lösel, P. J.; Lou, X.; Lounis, A.; Love, J.; Love, P. A.; Lu, H.; Lu, N.; Lu, Y. J.; Lubatti, H. J.; Luci, C.; Lucotte, A.; Luedtke, C.; Luehring, F.; Lukas, W.; Luminari, L.; Lund-Jensen, B.; Lutz, M. S.; Luzi, P. M.; Lynn, D.; Lysak, R.; Lytken, E.; Lyu, F.; Lyubushkin, V.; Ma, H.; Ma, L. L.; Ma, Y.; Maccarrone, G.; Macchiolo, A.; MacDonald, C. M.; Maček, B.; Machado Miguens, J.; Madaffari, D.; Madar, R.; Mader, W. F.; Madsen, A.; Madysa, N.; Maeda, J.; Maeland, S.; Maeno, T.; Maevskiy, A. S.; Magerl, V.; Maidantchik, C.; Maier, T.; Maio, A.; Majersky, O.; Majewski, S.; Makida, Y.; Makovec, N.; Malaescu, B.; Malecki, Pa.; Maleev, V. P.; Malek, F.; Mallik, U.; Malon, D.; Malone, C.; Maltezos, S.; Malyukov, S.; Mamuzic, J.; Mancini, G.; Mandić, I.; Maneira, J.; Manhaes de Andrade Filho, L.; Manjarres Ramos, J.; Mankinen, K. H.; Mann, A.; Manousos, A.; Mansoulie, B.; Mansour, J. D.; Mantifel, R.; Mantoani, M.; Manzoni, S.; Marceca, G.; March, L.; Marchese, L.; Marchiori, G.; Marcisovsky, M.; Marin Tobon, C. A.; Marjanovic, M.; Marley, D. E.; Marroquim, F.; Marshall, Z.; Martensson, M. U. F.; Marti-Garcia, S.; Martin, C. B.; Martin, T. A.; Martin, V. J.; Martin Dit Latour, B.; Martinez, M.; Martinez Outschoorn, V. I.; Martin-Haugh, S.; Martoiu, V. S.; Martyniuk, A. C.; Marzin, A.; Masetti, L.; Mashimo, T.; Mashinistov, R.; Masik, J.; Maslennikov, A. L.; Mason, L. H.; Massa, L.; Mastrandrea, P.; Mastroberardino, A.; Masubuchi, T.; Mättig, P.; Maurer, J.; Maxfield, S. J.; Maximov, D. A.; Mazini, R.; Maznas, I.; Mazza, S. M.; Mc Fadden, N. C.; Mc Goldrick, G.; Mc Kee, S. P.; McCarn, A.; McCarthy, T. G.; McClymont, L. I.; McDonald, E. F.; McFayden, J. A.; McHedlidze, G.; McKay, M. A.; McMahon, S. J.; McNamara, P. C.; McNicol, C. J.; McPherson, R. A.; Meadows, Z. A.; Meehan, S.; Megy, T. J.; Mehlhase, S.; Mehta, A.; Meideck, T.; Meier, K.; Meirose, B.; Melini, D.; Mellado Garcia, B. R.; Mellenthin, J. D.; Melo, M.; Meloni, F.; Melzer, A.; Menary, S. B.; Meng, L.; Meng, X. T.; Mengarelli, A.; Menke, S.; Meoni, E.; Mergelmeyer, S.; Merlassino, C.; Mermod, P.; Merola, L.; Meroni, C.; Merritt, F. S.; Messina, A.; Metcalfe, J.; Mete, A. S.; Meyer, C.; Meyer, J.-P.; Meyer, J.; Meyer Zu Theenhausen, H.; Miano, F.; Middleton, R. P.; Miglioranzi, S.; Mijović, L.; Mikenberg, G.; Mikestikova, M.; Mikuž, M.; Milesi, M.; Milic, A.; Millar, D. A.; Miller, D. W.; Milov, A.; Milstead, D. A.; Minaenko, A. A.; Minashvili, I. A.; Mincer, A. I.; Mindur, B.; Mineev, M.; Minegishi, Y.; Ming, Y.; Mir, L. M.; Mirto, A.; Mistry, K. P.; Mitani, T.; Mitrevski, J.; Mitsou, V. A.; Miucci, A.; Miyagawa, P. S.; Mizukami, A.; Mjörnmark, J. U.; Mkrtchyan, T.; Mlynarikova, M.; Moa, T.; Mochizuki, K.; Mogg, P.; Mohapatra, S.; Molander, S.; Moles-Valls, R.; Mondragon, M. C.; Mönig, K.; Monk, J.; Monnier, E.; Montalbano, A.; Montejo Berlingen, J.; Monticelli, F.; Monzani, S.; Moore, R. W.; Morange, N.; Moreno, D.; Moreno Llácer, M.; Morettini, P.; Morgenstern, M.; Morgenstern, S.; Mori, D.; Mori, T.; Morii, M.; Morinaga, M.; Morisbak, V.; Morley, A. K.; Mornacchi, G.; Morris, J. D.; Morvaj, L.; Moschovakos, P.; Mosidze, M.; Moss, H. J.; Moss, J.; Motohashi, K.; Mount, R.; Mountricha, E.; Moyse, E. J. W.; Muanza, S.; Mueller, F.; Mueller, J.; Mueller, R. S. P.; Muenstermann, D.; Mullen, P.; Mullier, G. A.; Munoz Sanchez, F. J.; Murin, P.; Murray, W. J.; Murrone, A.; Muškinja, M.; Mwewa, C.; Myagkov, A. G.; Myers, J.; Myska, M.; Nachman, B. P.; Nackenhorst, O.; Nagai, K.; Nagai, R.; Nagano, K.; Nagasaka, Y.; Nagata, K.; Nagel, M.; Nagy, E.; Nairz, A. M.; Nakahama, Y.; Nakamura, K.; Nakamura, T.; Nakano, I.; Naranjo Garcia, R. F.; Narayan, R.; Narrias Villar, D. I.; Naryshkin, I.; Naumann, T.; Navarro, G.; Nayyar, R.; Neal, H. A.; Nechaeva, P. Yu.; Neep, T. J.; Negri, A.; Negrini, M.; Nektarijevic, S.; Nellist, C.; Nelson, M. E.; Nemecek, S.; Nemethy, P.; Nessi, M.; Neubauer, M. S.; Neumann, M.; Newman, P. R.; Ng, T. Y.; Ng, Y. S.; Nguyen Manh, T.; Nickerson, R. B.; Nicolaidou, R.; Nielsen, J.; Nikiforou, N.; Nikolaenko, V.; Nikolic-Audit, I.; Nikolopoulos, K.; Nilsson, P.; Ninomiya, Y.; Nisati, A.; Nishu, N.; Nisius, R.; Nitsche, I.; Nitta, T.; Nobe, T.; Noguchi, Y.; Nomachi, M.; Nomidis, I.; Nomura, M. A.; Nooney, T.; Nordberg, M.; Norjoharuddeen, N.; Novgorodova, O.; Novotny, R.; Nozaki, M.; Nozka, L.; Ntekas, K.; Nurse, E.; Nuti, F.; O'Connor, K.; O'Neil, D. C.; O'Rourke, A. A.; O'Shea, V.; Oakham, F. G.; Oberlack, H.; Obermann, T.; Ocariz, J.; Ochi, A.; Ochoa, I.; Ochoa-Ricoux, J. P.; Oda, S.; Odaka, S.; Oh, A.; Oh, S. H.; Ohm, C. C.; Ohman, H.; Oide, H.; Ojeda, M. L.; Okawa, H.; Okumura, Y.; Okuyama, T.; Olariu, A.; Oleiro Seabra, L. F.; Olivares Pino, S. A.; Oliveira Damazio, D.; Oliver, J. L.; Olsson, M. J. R.; Olszewski, A.; Olszowska, J.; Onofre, A.; Onogi, K.; Onyisi, P. U. E.; Oppen, H.; Oreglia, M. J.; Oren, Y.; Orestano, D.; Orgill, E. C.; Orlando, N.; Orr, R. S.; Osculati, B.; Ospanov, R.; Otero Y Garzon, G.; Otono, H.; Ouchrif, M.; Ould-Saada, F.; Ouraou, A.; Oussoren, K. P.; Ouyang, Q.; Owen, M.; Owen, R. E.; Ozcan, V. E.; Ozturk, N.; Pachal, K.; Pacheco Pages, A.; Pacheco Rodriguez, L.; Padilla Aranda, C.; Pagan Griso, S.; Paganini, M.; Paige, F.; Palacino, G.; Palazzo, S.; Palestini, S.; Palka, M.; Pallin, D.; Panagiotopoulou, E. St.; Panagoulias, I.; Pandini, C. E.; Panduro Vazquez, J. G.; Pani, P.; Pantea, D.; Paolozzi, L.; Papadopoulou, Th. D.; Papageorgiou, K.; Paramonov, A.; Paredes Hernandez, D.; Parida, B.; Parker, A. J.; Parker, M. A.; Parker, K. A.; Parodi, F.; Parsons, J. A.; Parzefall, U.; Pascuzzi, V. R.; Pasner, J. M.; Pasqualucci, E.; Passaggio, S.; Pastore, Fr.; Pataraia, S.; Pater, J. R.; Pauly, T.; Pearson, B.; Pedraza Lopez, S.; Pedro, R.; Peleganchuk, S. V.; Penc, O.; Peng, C.; Peng, H.; Penwell, J.; Peralva, B. S.; Perego, M. M.; Perepelitsa, D. V.; Peri, F.; Perini, L.; Pernegger, H.; Perrella, S.; Peshekhonov, V. D.; Peters, K.; Peters, R. F. Y.; Petersen, B. A.; Petersen, T. C.; Petit, E.; Petridis, A.; Petridou, C.; Petroff, P.; Petrolo, E.; Petrov, M.; Petrucci, F.; Pettersson, N. E.; Peyaud, A.; Pezoa, R.; Pham, T.; Phillips, F. H.; Phillips, P. W.; Piacquadio, G.; Pianori, E.; Picazio, A.; Pickering, M. A.; Piegaia, R.; Pilcher, J. E.; Pilkington, A. D.; Pinamonti, M.; Pinfold, J. L.; Pitt, M.; Pleier, M.-A.; Pleskot, V.; Plotnikova, E.; Pluth, D.; Podberezko, P.; Poettgen, R.; Poggi, R.; Poggioli, L.; Pogrebnyak, I.; Pohl, D.; Pokharel, I.; Polesello, G.; Poley, A.; Policicchio, A.; Polifka, R.; Polini, A.; Pollard, C. S.; Polychronakos, V.; Ponomarenko, D.; Pontecorvo, L.; Popeneciu, G. A.; Portillo Quintero, D. M.; Pospisil, S.; Potamianos, K.; Potrap, I. N.; Potter, C. J.; Potti, H.; Poulsen, T.; Poveda, J.; Pozo Astigarraga, M. E.; Pralavorio, P.; Prell, S.; Price, D.; Primavera, M.; Prince, S.; Proklova, N.; Prokofiev, K.; Prokoshin, F.; Protopopescu, S.; Proudfoot, J.; Przybycien, M.; Puri, A.; Puzo, P.; Qian, J.; Qin, Y.; Quadt, A.; Queitsch-Maitland, M.; Qureshi, A.; Radeka, V.; Radhakrishnan, S. K.; Rados, P.; Ragusa, F.; Rahal, G.; Raine, J. A.; Rajagopalan, S.; Rashid, T.; Raspopov, S.; Ratti, M. G.; Rauch, D. M.; Rauscher, F.; Rave, S.; Ravinovich, I.; Rawling, J. H.; Raymond, M.; Read, A. L.; Readioff, N. P.; Reale, M.; Rebuzzi, D. M.; Redelbach, A.; Redlinger, G.; Reece, R.; Reed, R. G.; Reeves, K.; Rehnisch, L.; Reichert, J.; Reiss, A.; Rembser, C.; Ren, H.; Rescigno, M.; Resconi, S.; Resseguie, E. D.; Rettie, S.; Reynolds, E.; Rezanova, O. L.; Reznicek, P.; Richter, R.; Richter, S.; Richter-Was, E.; Ricken, O.; Ridel, M.; Rieck, P.; Riegel, C. J.; Rifki, O.; Rijssenbeek, M.; Rimoldi, A.; Rimoldi, M.; Rinaldi, L.; Ripellino, G.; Ristić, B.; Ritsch, E.; Riu, I.; Rivera Vergara, J. C.; Rizatdinova, F.; Rizvi, E.; Rizzi, C.; Roberts, R. T.; Robertson, S. H.; Robichaud-Veronneau, A.; Robinson, D.; Robinson, J. E. M.; Robson, A.; Rocco, E.; Roda, C.; Rodina, Y.; Rodriguez Bosca, S.; Rodriguez Perez, A.; Rodriguez Rodriguez, D.; Rodríguez Vera, A. M.; Roe, S.; Rogan, C. S.; Røhne, O.; Röhrig, R.; Roloff, J.; Romaniouk, A.; Romano, M.; Romano Saez, S. M.; Romero Adam, E.; Rompotis, N.; Ronzani, M.; Roos, L.; Rosati, S.; Rosbach, K.; Rose, P.; Rosien, N.-A.; Rossi, E.; Rossi, L. P.; Rossini, L.; Rosten, J. H. N.; Rosten, R.; Rotaru, M.; Rothberg, J.; Rousseau, D.; Roy, D.; Rozanov, A.; Rozen, Y.; Ruan, X.; Rubbo, F.; Rühr, F.; Ruiz-Martinez, A.; Rurikova, Z.; Rusakovich, N. A.; Russell, H. L.; Rutherfoord, J. P.; Ruthmann, N.; Rüttinger, E. M.; Ryabov, Y. F.; Rybar, M.; Rybkin, G.; Ryu, S.; Ryzhov, A.; Rzehorz, G. F.; Saavedra, A. F.; Sabato, G.; Sacerdoti, S.; Sadrozinski, H. F.-W.; Sadykov, R.; Safai Tehrani, F.; Saha, P.; Sahinsoy, M.; Saimpert, M.; Saito, M.; Saito, T.; Sakamoto, H.; Salamanna, G.; Salazar Loyola, J. E.; Salek, D.; Sales de Bruin, P. H.; Salihagic, D.; Salnikov, A.; Salt, J.; Salvatore, D.; Salvatore, F.; Salvucci, A.; Salzburger, A.; Sammel, D.; Sampsonidis, D.; Sampsonidou, D.; Sánchez, J.; Sanchez Pineda, A.; Sandaker, H.; Sander, C. O.; Sandhoff, M.; Sandoval, C.; Sankey, D. P. C.; Sannino, M.; Sano, Y.; Sansoni, A.; Santoni, C.; Santos, H.; Santoyo Castillo, I.; Sapronov, A.; Saraiva, J. G.; Sasaki, O.; Sato, K.; Sauvan, E.; Savard, P.; Savic, N.; Sawada, R.; Sawyer, C.; Sawyer, L.; Sbarra, C.; Sbrizzi, A.; Scanlon, T.; Scannicchio, D. A.; Schaarschmidt, J.; Schacht, P.; Schachtner, B. M.; Schaefer, D.; Schaefer, L.; Schaeffer, J.; Schaepe, S.; Schäfer, U.; Schaffer, A. C.; Schaile, D.; Schamberger, R. D.; Schegelsky, V. A.; Scheirich, D.; Schenck, F.; Schernau, M.; Schiavi, C.; Schier, S.; Schildgen, L. K.; Schillaci, Z. M.; Schillo, C.; Schioppa, E. J.; Schioppa, M.; Schleicher, K. E.; Schlenker, S.; Schmidt-Sommerfeld, K. R.; Schmieden, K.; Schmitt, C.; Schmitt, S.; Schmitz, S.; Schnoor, U.; Schoeffel, L.; Schoening, A.; Schopf, E.; Schott, M.; Schouwenberg, J. F. P.; Schovancova, J.; Schramm, S.; Schuh, N.; Schulte, A.; Schultz-Coulon, H.-C.; Schumacher, M.; Schumm, B. A.; Schune, Ph.; Schwartzman, A.; Schwarz, T. A.; Schweiger, H.; Schwemling, Ph.; Schwienhorst, R.; Schwindling, J.; Sciandra, A.; Sciolla, G.; Scornajenghi, M.; Scuri, F.; Scutti, F.; Scyboz, L. M.; Searcy, J.; Seema, P.; Seidel, S. C.; Seiden, A.; Seixas, J. M.; Sekhniaidze, G.; Sekhon, K.; Sekula, S. J.; Semprini-Cesari, N.; Senkin, S.; Serfon, C.; Serin, L.; Serkin, L.; Sessa, M.; Severini, H.; Šfiligoj, T.; Sforza, F.; Sfyrla, A.; Shabalina, E.; Shahinian, J. D.; Shaikh, N. W.; Shan, L. Y.; Shang, R.; Shank, J. T.; Shapiro, M.; Sharma, A. S.; Shatalov, P. B.; Shaw, K.; Shaw, S. M.; Shcherbakova, A.; Shehu, C. Y.; Shen, Y.; Sherafati, N.; Sherman, A. D.; Sherwood, P.; Shi, L.; Shimizu, S.; Shimmin, C. O.; Shimojima, M.; Shipsey, I. P. J.; Shirabe, S.; Shiyakova, M.; Shlomi, J.; Shmeleva, A.; Shoaleh Saadi, D.; Shochet, M. J.; Shojaii, S.; Shope, D. R.; Shrestha, S.; Shulga, E.; Sicho, P.; Sickles, A. M.; Sidebo, P. E.; Sideras Haddad, E.; Sidiropoulou, O.; Sidoti, A.; Siegert, F.; Sijacki, Dj.; Silva, J.; Silva, M.; Silverstein, S. B.; Simic, L.; Simion, S.; Simioni, E.; Simmons, B.; Simon, M.; Sinervo, P.; Sinev, N. B.; Sioli, M.; Siragusa, G.; Siral, I.; Sivoklokov, S. Yu.; Sjölin, J.; Skinner, M. B.; Skubic, P.; Slater, M.; Slavicek, T.; Slawinska, M.; Sliwa, K.; Slovak, R.; Smakhtin, V.; Smart, B. H.; Smiesko, J.; Smirnov, N.; Smirnov, S. Yu.; Smirnov, Y.; Smirnova, L. N.; Smirnova, O.; Smith, J. W.; Smith, M. N. K.; Smith, R. W.; Smizanska, M.; Smolek, K.; Snesarev, A. A.; Snyder, I. M.; Snyder, S.; Sobie, R.; Socher, F.; Soffa, A. M.; Soffer, A.; Søgaard, A.; Soh, D. A.; Sokhrannyi, G.; Solans Sanchez, C. A.; Solar, M.; Soldatov, E. Yu.; Soldevila, U.; Solodkov, A. A.; Soloshenko, A.; Solovyanov, O. V.; Solovyev, V.; Sommer, P.; Son, H.; Song, W.; Sopczak, A.; Sopkova, F.; Sosa, D.; Sotiropoulou, C. L.; Sottocornola, S.; Soualah, R.; Soukharev, A. M.; South, D.; Sowden, B. C.; Spagnolo, S.; Spalla, M.; Spangenberg, M.; Spanò, F.; Sperlich, D.; Spettel, F.; Spieker, T. M.; Spighi, R.; Spigo, G.; Spiller, L. A.; Spousta, M.; St. Denis, R. D.; Stabile, A.; Stamen, R.; Stamm, S.; Stanecka, E.; Stanek, R. W.; Stanescu, C.; Stanitzki, M. M.; Stapf, B. S.; Stapnes, S.; Starchenko, E. A.; Stark, G. H.; Stark, J.; Stark, S. H.; Staroba, P.; Starovoitov, P.; Stärz, S.; Staszewski, R.; Stegler, M.; Steinberg, P.; Stelzer, B.; Stelzer, H. J.; Stelzer-Chilton, O.; Stenzel, H.; Stevenson, T. J.; Stewart, G. A.; Stockton, M. C.; Stoicea, G.; Stolte, P.; Stonjek, S.; Straessner, A.; Stramaglia, M. E.; Strandberg, J.; Strandberg, S.; Strauss, M.; Strizenec, P.; Ströhmer, R.; Strom, D. M.; Stroynowski, R.; Strubig, A.; Stucci, S. A.; Stugu, B.; Styles, N. A.; Su, D.; Su, J.; Suchek, S.; Sugaya, Y.; Suk, M.; Sulin, V. V.; Sultan, D. M. S.; Sultansoy, S.; Sumida, T.; Sun, S.; Sun, X.; Suruliz, K.; Suster, C. J. E.; Sutton, M. R.; Suzuki, S.; Svatos, M.; Swiatlowski, M.; Swift, S. P.; Sydorenko, A.; Sykora, I.; Sykora, T.; Ta, D.; Tackmann, K.; Taenzer, J.; Taffard, A.; Tafirout, R.; Tahirovic, E.; Taiblum, N.; Takai, H.; Takashima, R.; Takasugi, E. H.; Takeda, K.; Takeshita, T.; Takubo, Y.; Talby, M.; Talyshev, A. A.; Tanaka, J.; Tanaka, M.; Tanaka, R.; Tanioka, R.; Tannenwald, B. B.; Tapia Araya, S.; Tapprogge, S.; Tarek Abouelfadl Mohamed, A. T.; Tarem, S.; Tarna, G.; Tartarelli, G. F.; Tas, P.; Tasevsky, M.; Tashiro, T.; Tassi, E.; Tavares Delgado, A.; Tayalati, Y.; Taylor, A. C.; Taylor, A. J.; Taylor, G. N.; Taylor, P. T. E.; Taylor, W.; Teixeira-Dias, P.; Temple, D.; Ten Kate, H.; Teng, P. K.; Teoh, J. J.; Tepel, F.; Terada, S.; Terashi, K.; Terron, J.; Terzo, S.; Testa, M.; Teuscher, R. J.; Thais, S. J.; Theveneaux-Pelzer, T.; Thiele, F.; Thomas, J. P.; Thompson, P. D.; Thompson, A. S.; Thomsen, L. A.; Thomson, E.; Tian, Y.; Ticse Torres, R. E.; Tikhomirov, V. O.; Tikhonov, Yu. A.; Timoshenko, S.; Tipton, P.; Tisserant, S.; Todome, K.; Todorova-Nova, S.; Todt, S.; Tojo, J.; Tokár, S.; Tokushuku, K.; Tolley, E.; Tomoto, M.; Tompkins, L.; Toms, K.; Tong, B.; Tornambe, P.; Torrence, E.; Torres, H.; Torró Pastor, E.; Toth, J.; Touchard, F.; Tovey, D. R.; Treado, C. J.; Trefzger, T.; Tresoldi, F.; Tricoli, A.; Trigger, I. M.; Trincaz-Duvoid, S.; Tripiana, M. F.; Trischuk, W.; Trocmé, B.; Trofymov, A.; Troncon, C.; Trovatelli, M.; Truong, L.; Trzebinski, M.; Trzupek, A.; Tsang, K. W.; Tseng, J. C.-L.; Tsiareshka, P. V.; Tsirintanis, N.; Tsiskaridze, S.; Tsiskaridze, V.; Tskhadadze, E. G.; Tsukerman, I. I.; Tsulaia, V.; Tsuno, S.; Tsybychev, D.; Tu, Y.; Tudorache, A.; Tudorache, V.; Tulbure, T. T.; Tuna, A. N.; Turchikhin, S.; Turgeman, D.; Turk Cakir, I.; Turra, R.; Tuts, P. M.; Ucchielli, G.; Ueda, I.; Ughetto, M.; Ukegawa, F.; Unal, G.; Undrus, A.; Unel, G.; Ungaro, F. C.; Unno, Y.; Uno, K.; Urban, J.; Urquijo, P.; Urrejola, P.; Usai, G.; Usui, J.; Vacavant, L.; Vacek, V.; Vachon, B.; Vadla, K. O. H.; Vaidya, A.; Valderanis, C.; Valdes Santurio, E.; Valente, M.; Valentinetti, S.; Valero, A.; Valéry, L.; Vallier, A.; Valls Ferrer, J. A.; van den Wollenberg, W.; van der Graaf, H.; van Gemmeren, P.; van Nieuwkoop, J.; van Vulpen, I.; van Woerden, M. C.; Vanadia, M.; Vandelli, W.; Vaniachine, A.; Vankov, P.; Vari, R.; Varnes, E. W.; Varni, C.; Varol, T.; Varouchas, D.; Vartapetian, A.; Varvell, K. E.; Vasquez, J. G.; Vasquez, G. A.; Vazeille, F.; Vazquez Furelos, D.; Vazquez Schroeder, T.; Veatch, J.; Vecchio, V.; Veloce, L. M.; Veloso, F.; Veneziano, S.; Ventura, A.; Venturi, M.; Venturi, N.; Vercesi, V.; Verducci, M.; Verkerke, W.; Vermeulen, A. T.; Vermeulen, J. C.; Vetterli, M. C.; Viaux Maira, N.; Viazlo, O.; Vichou, I.; Vickey, T.; Vickey Boeriu, O. E.; Viehhauser, G. H. A.; Viel, S.; Vigani, L.; Villa, M.; Villaplana Perez, M.; Vilucchi, E.; Vincter, M. G.; Vinogradov, V. B.; Vishwakarma, A.; Vittori, C.; Vivarelli, I.; Vlachos, S.; Vogel, M.; Vokac, P.; Volpi, G.; von Buddenbrock, S. E.; von Toerne, E.; Vorobel, V.; Vorobev, K.; Vos, M.; Vossebeld, J. H.; Vranjes, N.; Vranjes Milosavljevic, M.; Vrba, V.; Vreeswijk, M.; Vuillermet, R.; Vukotic, I.; Wagner, P.; Wagner, W.; Wagner-Kuhr, J.; Wahlberg, H.; Wahrmund, S.; Wakamiya, K.; Walder, J.; Walker, R.; Walkowiak, W.; Wallangen, V.; Wang, A. M.; Wang, C.; Wang, F.; Wang, H.; Wang, H.; Wang, J.; Wang, J.; Wang, Q.; Wang, R.-J.; Wang, R.; Wang, S. M.; Wang, T.; Wang, W.; Wang, W.; Wang, Z.; Wanotayaroj, C.; Warburton, A.; Ward, C. P.; Wardrope, D. R.; Washbrook, A.; Watkins, P. M.; Watson, A. T.; Watson, M. F.; Watts, G.; Watts, S.; Waugh, B. M.; Webb, A. F.; Webb, S.; Weber, M. S.; Weber, S. M.; Weber, S. A.; Webster, J. S.; Weidberg, A. R.; Weinert, B.; Weingarten, J.; Weirich, M.; Weiser, C.; Wells, P. S.; Wenaus, T.; Wengler, T.; Wenig, S.; Wermes, N.; Werner, M. D.; Werner, P.; Wessels, M.; Weston, T. D.; Whalen, K.; Whallon, N. L.; Wharton, A. M.; White, A. S.; White, A.; White, M. J.; White, R.; Whiteson, D.; Whitmore, B. W.; Wickens, F. J.; Wiedenmann, W.; Wielers, M.; Wiglesworth, C.; Wiik-Fuchs, L. A. M.; Wildauer, A.; Wilk, F.; Wilkens, H. G.; Williams, H. H.; Williams, S.; Willis, C.; Willocq, S.; Wilson, J. A.; Wingerter-Seez, I.; Winkels, E.; Winklmeier, F.; Winston, O. J.; Winter, B. T.; Wittgen, M.; Wobisch, M.; Wolf, A.; Wolf, T. M. H.; Wolff, R.; Wolter, M. W.; Wolters, H.; Wong, V. W. S.; Woods, N. L.; Worm, S. D.; Wosiek, B. K.; Wozniak, K. W.; Wu, M.; Wu, S. L.; Wu, X.; Wu, Y.; Wyatt, T. R.; Wynne, B. M.; Xella, S.; Xi, Z.; Xia, L.; Xu, D.; Xu, L.; Xu, T.; Xu, W.; Yabsley, B.; Yacoob, S.; Yajima, K.; Yallup, D. P.; Yamaguchi, D.; Yamaguchi, Y.; Yamamoto, A.; Yamanaka, T.; Yamane, F.; Yamatani, M.; Yamazaki, T.; Yamazaki, Y.; Yan, Z.; Yang, H.; Yang, H.; Yang, S.; Yang, Y.; Yang, Z.; Yao, W.-M.; Yap, Y. C.; Yasu, Y.; Yatsenko, E.; Yau Wong, K. H.; Ye, J.; Ye, S.; Yeletskikh, I.; Yigitbasi, E.; Yildirim, E.; Yorita, K.; Yoshihara, K.; Young, C.; Young, C. J. S.; Yu, J.; Yu, J.; Yuen, S. P. Y.; Yusuff, I.; Zabinski, B.; Zacharis, G.; Zaidan, R.; Zaitsev, A. M.; Zakharchuk, N.; Zalieckas, J.; Zambito, S.; Zanzi, D.; Zeitnitz, C.; Zemaityte, G.; Zeng, J. C.; Zeng, Q.; Zenin, O.; Ženiš, T.; Zerwas, D.; Zhang, D.; Zhang, D.; Zhang, F.; Zhang, G.; Zhang, H.; Zhang, J.; Zhang, L.; Zhang, L.; Zhang, M.; Zhang, P.; Zhang, R.; Zhang, R.; Zhang, X.; Zhang, Y.; Zhang, Z.; Zhao, X.; Zhao, Y.; Zhao, Z.; Zhemchugov, A.; Zhou, B.; Zhou, C.; Zhou, L.; Zhou, M.; Zhou, M.; Zhou, N.; Zhou, Y.; Zhu, C. G.; Zhu, H.; Zhu, J.; Zhu, Y.; Zhuang, X.; Zhukov, K.; Zhulanov, V.; Zibell, A.; Zieminska, D.; Zimine, N. I.; Zimmermann, S.; Zinonos, Z.; Zinser, M.; Ziolkowski, M.; Živković, L.; Zobernig, G.; Zoccoli, A.; Zou, R.; Zur Nedden, M.; Zwalinski, L.; Atlas Collaboration
2018-04-01
A search for the associated production of the Higgs boson with a top quark pair (t t ¯H ) is reported. The search is performed in multilepton final states using a data set corresponding to an integrated luminosity of 36.1 fb-1 of proton-proton collision data recorded by the ATLAS experiment at a center-of-mass energy √{s }=13 TeV at the Large Hadron Collider. Higgs boson decays to W W*, τ τ , and Z Z* are targeted. Seven final states, categorized by the number and flavor of charged-lepton candidates, are examined for the presence of the Standard Model Higgs boson with a mass of 125 GeV and a pair of top quarks. An excess of events over the expected background from Standard Model processes is found with an observed significance of 4.1 standard deviations, compared to an expectation of 2.8 standard deviations. The best fit for the t t ¯H production cross section is σ (t t ¯H )=79 0-210+230 fb , in agreement with the Standard Model prediction of 50 7-50+35 fb . The combination of this result with other t t ¯H searches from the ATLAS experiment using the Higgs boson decay modes to b b ¯, γ γ and Z Z*→4 ℓ, has an observed significance of 4.2 standard deviations, compared to an expectation of 3.8 standard deviations. This provides evidence for the t t ¯H production mode.
WASP (Write a Scientific Paper) using Excel -5: Quartiles and standard deviation.
Grech, Victor
2018-03-01
The almost inevitable descriptive statistics exercise that is undergone once data collection is complete, prior to inferential statistics, requires the acquisition of basic descriptors which may include standard deviation and quartiles. This paper provides pointers as to how to do this in Microsoft Excel™ and explains the relationship between the two. Copyright © 2018 Elsevier B.V. All rights reserved.
Validation Test Report for GDEM4
2010-08-19
standard deviations called the Generalized Digital Environmental Model ( GDEM ). The present document describes the development and evaluation of GDEM4...the newest version of GDEM . As part of the evaluation of GDEM4, comparisons are made in this report to GDEM3 and to four other ocean climatologies...depth climatology of temperature and salinity and their standard deviations called the Generalized Digital Environmental Model ( GDEM ). The history of
40 CFR 91.508 - Cumulative Sum (CumSum) procedure.
Code of Federal Regulations, 2010 CFR
2010-07-01
... family may be determined to be in noncompliance for purposes of § 91.510. H = The Action Limit. It is 5.0 × σ, and is a function of the standard deviation, σ. σ = is the sample standard deviation and is... Equation must be final deteriorated test results as defined in § 91.509(c). Ci = max[0 0R (Ci-1 + Xi − (FEL...
NASA Astrophysics Data System (ADS)
Larsson, R.; Milz, M.; Rayer, P.; Saunders, R.; Bell, W.; Booton, A.; Buehler, S. A.; Eriksson, P.; John, V.
2015-10-01
We present a comparison of a reference and a fast radiative transfer model using numerical weather prediction profiles for the Zeeman-affected high altitude Special Sensor Microwave Imager/Sounder channels 19-22. We find that the models agree well for channels 21 and 22 compared to the channels' system noise temperatures (1.9 and 1.3 K, respectively) and the expected profile errors at the affected altitudes (estimated to be around 5 K). For channel 22 there is a 0.5 K average difference between the models, with a standard deviation of 0.24 K for the full set of atmospheric profiles. Same channel, there is 1.2 K in average between the fast model and the sensor measurement, with 1.4 K standard deviation. For channel 21 there is a 0.9 K average difference between the models, with a standard deviation of 0.56 K. Same channel, there is 1.3 K in average between the fast model and the sensor measurement, with 2.4 K standard deviation. We consider the relatively small model differences as a validation of the fast Zeeman effect scheme for these channels. Both channels 19 and 20 have smaller average differences between the models (at below 0.2 K) and smaller standard deviations (at below 0.4 K) when both models use a two-dimensional magnetic field profile. However, when the reference model is switched to using a full three-dimensional magnetic field profile, the standard deviation to the fast model is increased to almost 2 K due to viewing geometry dependencies causing up to ± 7 K differences near the equator. The average differences between the two models remain small despite changing magnetic field configurations. We are unable to compare channels 19 and 20 to sensor measurements due to limited altitude range of the numerical weather prediction profiles. We recommended that numerical weather prediction software using the fast model takes the available fast Zeeman scheme into account for data assimilation of the affected sensor channels to better constrain the upper atmospheric temperatures.
NASA Astrophysics Data System (ADS)
Larsson, Richard; Milz, Mathias; Rayer, Peter; Saunders, Roger; Bell, William; Booton, Anna; Buehler, Stefan A.; Eriksson, Patrick; John, Viju O.
2016-03-01
We present a comparison of a reference and a fast radiative transfer model using numerical weather prediction profiles for the Zeeman-affected high-altitude Special Sensor Microwave Imager/Sounder channels 19-22. We find that the models agree well for channels 21 and 22 compared to the channels' system noise temperatures (1.9 and 1.3 K, respectively) and the expected profile errors at the affected altitudes (estimated to be around 5 K). For channel 22 there is a 0.5 K average difference between the models, with a standard deviation of 0.24 K for the full set of atmospheric profiles. Concerning the same channel, there is 1.2 K on average between the fast model and the sensor measurement, with 1.4 K standard deviation. For channel 21 there is a 0.9 K average difference between the models, with a standard deviation of 0.56 K. Regarding the same channel, there is 1.3 K on average between the fast model and the sensor measurement, with 2.4 K standard deviation. We consider the relatively small model differences as a validation of the fast Zeeman effect scheme for these channels. Both channels 19 and 20 have smaller average differences between the models (at below 0.2 K) and smaller standard deviations (at below 0.4 K) when both models use a two-dimensional magnetic field profile. However, when the reference model is switched to using a full three-dimensional magnetic field profile, the standard deviation to the fast model is increased to almost 2 K due to viewing geometry dependencies, causing up to ±7 K differences near the equator. The average differences between the two models remain small despite changing magnetic field configurations. We are unable to compare channels 19 and 20 to sensor measurements due to limited altitude range of the numerical weather prediction profiles. We recommended that numerical weather prediction software using the fast model takes the available fast Zeeman scheme into account for data assimilation of the affected sensor channels to better constrain the upper atmospheric temperatures.
Spectral combination of spherical gravitational curvature boundary-value problems
NASA Astrophysics Data System (ADS)
PitoÅák, Martin; Eshagh, Mehdi; Šprlák, Michal; Tenzer, Robert; Novák, Pavel
2018-04-01
Four solutions of the spherical gravitational curvature boundary-value problems can be exploited for the determination of the Earth's gravitational potential. In this article we discuss the combination of simulated satellite gravitational curvatures, i.e., components of the third-order gravitational tensor, by merging these solutions using the spectral combination method. For this purpose, integral estimators of biased- and unbiased-types are derived. In numerical studies, we investigate the performance of the developed mathematical models for the gravitational field modelling in the area of Central Europe based on simulated satellite measurements. Firstly, we verify the correctness of the integral estimators for the spectral downward continuation by a closed-loop test. Estimated errors of the combined solution are about eight orders smaller than those from the individual solutions. Secondly, we perform a numerical experiment by considering the Gaussian noise with the standard deviation of 6.5× 10-17 m-1s-2 in the input data at the satellite altitude of 250 km above the mean Earth sphere. This value of standard deviation is equivalent to a signal-to-noise ratio of 10. Superior results with respect to the global geopotential model TIM-r5 are obtained by the spectral downward continuation of the vertical-vertical-vertical component with the standard deviation of 2.104 m2s-2, but the root mean square error is the largest and reaches 9.734 m2s-2. Using the spectral combination of all gravitational curvatures the root mean square error is more than 400 times smaller but the standard deviation reaches 17.234 m2s-2. The combination of more components decreases the root mean square error of the corresponding solutions while the standard deviations of the combined solutions do not improve as compared to the solution from the vertical-vertical-vertical component. The presented method represents a weight mean in the spectral domain that minimizes the root mean square error of the combined solutions and improves standard deviation of the solution based only on the least accurate components.
NASA Astrophysics Data System (ADS)
Stier, P.; Schutgens, N. A. J.; Bellouin, N.; Bian, H.; Boucher, O.; Chin, M.; Ghan, S.; Huneeus, N.; Kinne, S.; Lin, G.; Ma, X.; Myhre, G.; Penner, J. E.; Randles, C. A.; Samset, B.; Schulz, M.; Takemura, T.; Yu, F.; Yu, H.; Zhou, C.
2013-03-01
Simulated multi-model "diversity" in aerosol direct radiative forcing estimates is often perceived as a measure of aerosol uncertainty. However, current models used for aerosol radiative forcing calculations vary considerably in model components relevant for forcing calculations and the associated "host-model uncertainties" are generally convoluted with the actual aerosol uncertainty. In this AeroCom Prescribed intercomparison study we systematically isolate and quantify host model uncertainties on aerosol forcing experiments through prescription of identical aerosol radiative properties in twelve participating models. Even with prescribed aerosol radiative properties, simulated clear-sky and all-sky aerosol radiative forcings show significant diversity. For a purely scattering case with globally constant optical depth of 0.2, the global-mean all-sky top-of-atmosphere radiative forcing is -4.47 Wm-2 and the inter-model standard deviation is 0.55 Wm-2, corresponding to a relative standard deviation of 12%. For a case with partially absorbing aerosol with an aerosol optical depth of 0.2 and single scattering albedo of 0.8, the forcing changes to 1.04 Wm-2, and the standard deviation increases to 1.01 W-2, corresponding to a significant relative standard deviation of 97%. However, the top-of-atmosphere forcing variability owing to absorption (subtracting the scattering case from the case with scattering and absorption) is low, with absolute (relative) standard deviations of 0.45 Wm-2 (8%) clear-sky and 0.62 Wm-2 (11%) all-sky. Scaling the forcing standard deviation for a purely scattering case to match the sulfate radiative forcing in the AeroCom Direct Effect experiment demonstrates that host model uncertainties could explain about 36% of the overall sulfate forcing diversity of 0.11 Wm-2 in the AeroCom Direct Radiative Effect experiment. Host model errors in aerosol radiative forcing are largest in regions of uncertain host model components, such as stratocumulus cloud decks or areas with poorly constrained surface albedos, such as sea ice. Our results demonstrate that host model uncertainties are an important component of aerosol forcing uncertainty that require further attention.
Quantifying the heterogeneity of the tectonic stress field using borehole data
Schoenball, Martin; Davatzes, Nicholas C.
2017-01-01
The heterogeneity of the tectonic stress field is a fundamental property which influences earthquake dynamics and subsurface engineering. Self-similar scaling of stress heterogeneities is frequently assumed to explain characteristics of earthquakes such as the magnitude-frequency relation. However, observational evidence for such scaling of the stress field heterogeneity is scarce.We analyze the local stress orientations using image logs of two closely spaced boreholes in the Coso Geothermal Field with sub-vertical and deviated trajectories, respectively, each spanning about 2 km in depth. Both the mean and the standard deviation of stress orientation indicators (borehole breakouts, drilling-induced fractures and petal-centerline fractures) determined from each borehole agree to the limit of the resolution of our method although measurements at specific depths may not. We find that the standard deviation in these boreholes strongly depends on the interval length analyzed, generally increasing up to a wellbore log length of about 600 m and constant for longer intervals. We find the same behavior in global data from the World Stress Map. This suggests that the standard deviation of stress indicators characterizes the heterogeneity of the tectonic stress field rather than the quality of the stress measurement. A large standard deviation of a stress measurement might be an expression of strong crustal heterogeneity rather than of an unreliable stress determination. Robust characterization of stress heterogeneity requires logs that sample stress indicators along a representative sample volume of at least 1 km.
[Effect strength variation in the single group pre-post study design: a critical review].
Maier-Riehle, B; Zwingmann, C
2000-08-01
In Germany, studies in rehabilitation research--in particular evaluation studies and examinations of quality of outcome--have so far mostly been executed according to the uncontrolled one-group pre-post design. Assessment of outcome is usually made by comparing the pre- and post-treatment means of the outcome variables. The pre-post differences are checked, and in case of significance, the results are increasingly presented in form of effect sizes. For this reason, this contribution presents different effect size indices used for the one-group pre-post design--in spite of fundamental doubts which exist in relation to that design due to its limited internal validity. The numerator concerning all effect size indices of the one-group pre-post design is defined as difference between the pre- and post-treatment means, whereas there are different possibilities and recommendations with regard to the denominator and hence the standard deviation that serves as the basis for standardizing the difference of the means. Used above all are standardization oriented towards the standard deviation of the pre-treatment scores, standardization oriented towards the pooled standard deviation of the pre- and post-treatment scores, and standardization oriented towards the standard deviation of the pre-post differences. Two examples are given to demonstrate that the different modes of calculating effect size indices in the one-group pre-post design may lead to very different outcome patterns. Additionally, it is pointed out that effect sizes from the uncontrolled one-group pre-post design generally tend to be higher than effect sizes from studies conducted with control groups. Finally, the pros and cons of the different effect size indices are discussed and recommendations are given.
Size-dependent standard deviation for growth rates: Empirical results and theoretical modeling
NASA Astrophysics Data System (ADS)
Podobnik, Boris; Horvatic, Davor; Pammolli, Fabio; Wang, Fengzhong; Stanley, H. Eugene; Grosse, I.
2008-05-01
We study annual logarithmic growth rates R of various economic variables such as exports, imports, and foreign debt. For each of these variables we find that the distributions of R can be approximated by double exponential (Laplace) distributions in the central parts and power-law distributions in the tails. For each of these variables we further find a power-law dependence of the standard deviation σ(R) on the average size of the economic variable with a scaling exponent surprisingly close to that found for the gross domestic product (GDP) [Phys. Rev. Lett. 81, 3275 (1998)]. By analyzing annual logarithmic growth rates R of wages of 161 different occupations, we find a power-law dependence of the standard deviation σ(R) on the average value of the wages with a scaling exponent β≈0.14 close to those found for the growth of exports, imports, debt, and the growth of the GDP. In contrast to these findings, we observe for payroll data collected from 50 states of the USA that the standard deviation σ(R) of the annual logarithmic growth rate R increases monotonically with the average value of payroll. However, also in this case we observe a power-law dependence of σ(R) on the average payroll with a scaling exponent β≈-0.08 . Based on these observations we propose a stochastic process for multiple cross-correlated variables where for each variable (i) the distribution of logarithmic growth rates decays exponentially in the central part, (ii) the distribution of the logarithmic growth rate decays algebraically in the far tails, and (iii) the standard deviation of the logarithmic growth rate depends algebraically on the average size of the stochastic variable.
Pardo, Deborah; Jenouvrier, Stéphanie; Weimerskirch, Henri; Barbraud, Christophe
2017-06-19
Climate changes include concurrent changes in environmental mean, variance and extremes, and it is challenging to understand their respective impact on wild populations, especially when contrasted age-dependent responses to climate occur. We assessed how changes in mean and standard deviation of sea surface temperature (SST), frequency and magnitude of warm SST extreme climatic events (ECE) influenced the stochastic population growth rate log( λ s ) and age structure of a black-browed albatross population. For changes in SST around historical levels observed since 1982, changes in standard deviation had a larger (threefold) and negative impact on log( λ s ) compared to changes in mean. By contrast, the mean had a positive impact on log( λ s ). The historical SST mean was lower than the optimal SST value for which log( λ s ) was maximized. Thus, a larger environmental mean increased the occurrence of SST close to this optimum that buffered the negative effect of ECE. This 'climate safety margin' (i.e. difference between optimal and historical climatic conditions) and the specific shape of the population growth rate response to climate for a species determine how ECE affect the population. For a wider range in SST, both the mean and standard deviation had negative impact on log( λ s ), with changes in the mean having a greater effect than the standard deviation. Furthermore, around SST historical levels increases in either mean or standard deviation of the SST distribution led to a younger population, with potentially important conservation implications for black-browed albatrosses.This article is part of the themed issue 'Behavioural, ecological and evolutionary responses to extreme climatic events'. © 2017 The Author(s).
Is standard deviation of daily PM2.5 concentration associated with respiratory mortality?
Lin, Hualiang; Ma, Wenjun; Qiu, Hong; Vaughn, Michael G; Nelson, Erik J; Qian, Zhengmin; Tian, Linwei
2016-09-01
Studies on health effects of air pollution often use daily mean concentration to estimate exposure while ignoring daily variations. This study examined the health effects of daily variation of PM2.5. We calculated daily mean and standard deviations of PM2.5 in Hong Kong between 1998 and 2011. We used a generalized additive model to estimate the association between respiratory mortality and daily mean and variation of PM2.5, as well as their interaction. We controlled for potential confounders, including temporal trends, day of the week, meteorological factors, and gaseous air pollutants. Both daily mean and standard deviation of PM2.5 were significantly associated with mortalities from overall respiratory diseases and pneumonia. Each 10 μg/m(3) increment in daily mean concentration at lag 2 day was associated with a 0.61% (95% CI: 0.19%, 1.03%) increase in overall respiratory mortality and a 0.67% (95% CI: 0.14%, 1.21%) increase in pneumonia mortality. And a 10 μg/m(3) increase in standard deviation at lag 1 day corresponded to a 1.40% (95% CI: 0.35%, 2.46%) increase in overall respiratory mortality, and a 1.80% (95% CI: 0.46%, 3.16%) increase in pneumonia mortality. We also observed a positive but non-significant synergistic interaction between daily mean and variation on respiratory mortality and pneumonia mortality. However, we did not find any significant association with mortality from chronic obstructive pulmonary diseases. Our study suggests that, besides mean concentration, the standard deviation of PM2.5 might be one potential predictor of respiratory mortality in Hong Kong, and should be considered when assessing the respiratory effects of PM2.5. Copyright © 2016 Elsevier Ltd. All rights reserved.
Assessment issues in the testing of children at school entry.
Rock, Donald A; Stenner, A Jackson
2005-01-01
The authors introduce readers to the research documenting racial and ethnic gaps in school readiness. They describe the key tests, including the Peabody Picture Vocabulary Test (PPVT), the Early Childhood Longitudinal Study (ECLS), and several intelligence tests, and describe how they have been administered to several important national samples of children. Next, the authors review the different estimates of the gaps and discuss how to interpret these differences. In interpreting test results, researchers use the statistical term "standard deviation" to compare scores across the tests. On average, the tests find a gap of about 1 standard deviation. The ECLS-K estimate is the lowest, about half a standard deviation. The PPVT estimate is the highest, sometimes more than 1 standard deviation. When researchers adjust those gaps statistically to take into account different outside factors that might affect children's test scores, such as family income or home environment, the gap narrows but does not disappear. Why such different estimates of the gap? The authors consider explanations such as differences in the samples, racial or ethnic bias in the tests, and whether the tests reflect different aspects of school "readiness," and conclude that none is likely to explain the varying estimates. Another possible explanation is the Spearman Hypothesis-that all tests are imperfect measures of a general ability construct, g; the more highly a given test correlates with g, the larger the gap will be. But the Spearman Hypothesis, too, leaves questions to be investigated. A gap of 1 standard deviation may not seem large, but the authors show clearly how it results in striking disparities in the performance of black and white students and why it should be of serious concern to policymakers.
Single-Station Sigma for the Iranian Strong Motion Stations
NASA Astrophysics Data System (ADS)
Zafarani, H.; Soghrat, M. R.
2017-11-01
In development of ground motion prediction equations (GMPEs), the residuals are assumed to have a log-normal distribution with a zero mean and a standard deviation, designated as sigma. Sigma has significant effect on evaluation of seismic hazard for designing important infrastructures such as nuclear power plants and dams. Both aleatory and epistemic uncertainties are involved in the sigma parameter. However, ground-motion observations over long time periods are not available at specific sites and the GMPEs have been derived using observed data from multiple sites for a small number of well-recorded earthquakes. Therefore, sigma is dominantly related to the statistics of the spatial variability of ground motion instead of temporal variability at a single point (ergodic assumption). The main purpose of this study is to reduce the variability of the residuals so as to handle it as epistemic uncertainty. In this regard, it is tried to partially apply the non-ergodic assumption by removing repeatable site effects from total variability of six GMPEs driven from the local, Europe-Middle East and worldwide data. For this purpose, we used 1837 acceleration time histories from 374 shallow earthquakes with moment magnitudes ranging from M w 4.0 to 7.3 recorded at 370 stations with at least two recordings per station. According to estimated single-station sigma for the Iranian strong motion stations, the ratio of event-corrected single-station standard deviation ( Φ ss) to within-event standard deviation ( Φ) is about 0.75. In other words, removing the ergodic assumption on site response resulted in 25% reduction of the within-event standard deviation that reduced the total standard deviation by about 15%.
Improving IQ measurement in intellectual disabilities using true deviation from population norms
2014-01-01
Background Intellectual disability (ID) is characterized by global cognitive deficits, yet the very IQ tests used to assess ID have limited range and precision in this population, especially for more impaired individuals. Methods We describe the development and validation of a method of raw z-score transformation (based on general population norms) that ameliorates floor effects and improves the precision of IQ measurement in ID using the Stanford Binet 5 (SB5) in fragile X syndrome (FXS; n = 106), the leading inherited cause of ID, and in individuals with idiopathic autism spectrum disorder (ASD; n = 205). We compared the distributional characteristics and Q-Q plots from the standardized scores with the deviation z-scores. Additionally, we examined the relationship between both scoring methods and multiple criterion measures. Results We found evidence that substantial and meaningful variation in cognitive ability on standardized IQ tests among individuals with ID is lost when converting raw scores to standardized scaled, index and IQ scores. Use of the deviation z- score method rectifies this problem, and accounts for significant additional variance in criterion validation measures, above and beyond the usual IQ scores. Additionally, individual and group-level cognitive strengths and weaknesses are recovered using deviation scores. Conclusion Traditional methods for generating IQ scores in lower functioning individuals with ID are inaccurate and inadequate, leading to erroneously flat profiles. However assessment of cognitive abilities is substantially improved by measuring true deviation in performance from standardization sample norms. This work has important implications for standardized test development, clinical assessment, and research for which IQ is an important measure of interest in individuals with neurodevelopmental disorders and other forms of cognitive impairment. PMID:26491488
Size-dependent standard deviation for growth rates: empirical results and theoretical modeling.
Podobnik, Boris; Horvatic, Davor; Pammolli, Fabio; Wang, Fengzhong; Stanley, H Eugene; Grosse, I
2008-05-01
We study annual logarithmic growth rates R of various economic variables such as exports, imports, and foreign debt. For each of these variables we find that the distributions of R can be approximated by double exponential (Laplace) distributions in the central parts and power-law distributions in the tails. For each of these variables we further find a power-law dependence of the standard deviation sigma(R) on the average size of the economic variable with a scaling exponent surprisingly close to that found for the gross domestic product (GDP) [Phys. Rev. Lett. 81, 3275 (1998)]. By analyzing annual logarithmic growth rates R of wages of 161 different occupations, we find a power-law dependence of the standard deviation sigma(R) on the average value of the wages with a scaling exponent beta approximately 0.14 close to those found for the growth of exports, imports, debt, and the growth of the GDP. In contrast to these findings, we observe for payroll data collected from 50 states of the USA that the standard deviation sigma(R) of the annual logarithmic growth rate R increases monotonically with the average value of payroll. However, also in this case we observe a power-law dependence of sigma(R) on the average payroll with a scaling exponent beta approximately -0.08 . Based on these observations we propose a stochastic process for multiple cross-correlated variables where for each variable (i) the distribution of logarithmic growth rates decays exponentially in the central part, (ii) the distribution of the logarithmic growth rate decays algebraically in the far tails, and (iii) the standard deviation of the logarithmic growth rate depends algebraically on the average size of the stochastic variable.
Improving IQ measurement in intellectual disabilities using true deviation from population norms.
Sansone, Stephanie M; Schneider, Andrea; Bickel, Erika; Berry-Kravis, Elizabeth; Prescott, Christina; Hessl, David
2014-01-01
Intellectual disability (ID) is characterized by global cognitive deficits, yet the very IQ tests used to assess ID have limited range and precision in this population, especially for more impaired individuals. We describe the development and validation of a method of raw z-score transformation (based on general population norms) that ameliorates floor effects and improves the precision of IQ measurement in ID using the Stanford Binet 5 (SB5) in fragile X syndrome (FXS; n = 106), the leading inherited cause of ID, and in individuals with idiopathic autism spectrum disorder (ASD; n = 205). We compared the distributional characteristics and Q-Q plots from the standardized scores with the deviation z-scores. Additionally, we examined the relationship between both scoring methods and multiple criterion measures. We found evidence that substantial and meaningful variation in cognitive ability on standardized IQ tests among individuals with ID is lost when converting raw scores to standardized scaled, index and IQ scores. Use of the deviation z- score method rectifies this problem, and accounts for significant additional variance in criterion validation measures, above and beyond the usual IQ scores. Additionally, individual and group-level cognitive strengths and weaknesses are recovered using deviation scores. Traditional methods for generating IQ scores in lower functioning individuals with ID are inaccurate and inadequate, leading to erroneously flat profiles. However assessment of cognitive abilities is substantially improved by measuring true deviation in performance from standardization sample norms. This work has important implications for standardized test development, clinical assessment, and research for which IQ is an important measure of interest in individuals with neurodevelopmental disorders and other forms of cognitive impairment.
Validation of 10 years of SAO OMI Ozone Profiles with Ozonesonde and MLS Observations
NASA Astrophysics Data System (ADS)
Huang, G.; Liu, X.; Chance, K.; Bhartia, P. K.
2015-12-01
To evaluate the accuracy and long-term stability of the SAO OMI ozone profile product, we validate ~10 years of ozone profile product (Oct. 2004-Dec. 2014) against collocated ozonesonde and MLS data. Ozone profiles as well stratospheric, tropospheric, lower tropospheric ozone columns are compared with ozonesonde data for different latitude bands, and time periods (e.g., 2004-2008/2009-2014 for without/with row anomaly. The mean biases and their standard deviations are also assessed as a function of time to evaluate the long-term stability and bias trends. In the mid-latitude and tropical regions, OMI generally shows good agreement with ozonesonde observations. The mean ozone profile biases are generally within 6% with up to 30% standard deviations. The biases of stratospheric ozone columns (SOC) and tropospheric ozone columns (TOC) are -0.3%-2.2% and -0.2%-3%, while standard deviations are 3.9%-5.8% and 14.4%-16.0%, respectively. However, the retrievals during 2009-2014 show larger standard deviations and larger temporal variations; the standard deviations increase by ~5% in the troposphere and ~2% in the stratosphere. Retrieval biases at individual levels in the stratosphere and upper troposphere show statistically significant trends and different trends for 2004-2008 and 2009-2014 periods. The trends in integrated ozone partial columns are less significant due to cancellation from various layers, except for significant trend in tropical SOC. These results suggest the need to perform time dependent radiometric calibration to maintain the long-term stability of this product. Similarly, we are comparing the OMI stratospheric ozone profiles and SOC with collocated MLS data, and the results will be reported.
Revert Ventura, A J; Sanz Requena, R; Martí-Bonmatí, L; Pallardó, Y; Jornet, J; Gaspar, C
2014-01-01
To study whether the histograms of quantitative parameters of perfusion in MRI obtained from tumor volume and peritumor volume make it possible to grade astrocytomas in vivo. We included 61 patients with histological diagnoses of grade II, III, or IV astrocytomas who underwent T2*-weighted perfusion MRI after intravenous contrast agent injection. We manually selected the tumor volume and peritumor volume and quantified the following perfusion parameters on a voxel-by-voxel basis: blood volume (BV), blood flow (BF), mean transit time (TTM), transfer constant (K(trans)), washout coefficient, interstitial volume, and vascular volume. For each volume, we obtained the corresponding histogram with its mean, standard deviation, and kurtosis (using the standard deviation and kurtosis as measures of heterogeneity) and we compared the differences in each parameter between different grades of tumor. We also calculated the mean and standard deviation of the highest 10% of values. Finally, we performed a multiparametric discriminant analysis to improve the classification. For tumor volume, we found statistically significant differences among the three grades of tumor for the means and standard deviations of BV, BF, and K(trans), both for the entire distribution and for the highest 10% of values. For the peritumor volume, we found no significant differences for any parameters. The discriminant analysis improved the classification slightly. The quantification of the volume parameters of the entire region of the tumor with BV, BF, and K(trans) is useful for grading astrocytomas. The heterogeneity represented by the standard deviation of BF is the most reliable diagnostic parameter for distinguishing between low grade and high grade lesions. Copyright © 2011 SERAM. Published by Elsevier Espana. All rights reserved.
NASA Astrophysics Data System (ADS)
Schupp, C. A.; McNinch, J. E.; List, J. H.; Farris, A. S.
2002-12-01
The formation and behavior of hotspots, or sections of the beach that exhibit markedly higher shoreline change rates than adjacent regions, are poorly understood. Several hotspots have been identified on the Outer Banks, a developed barrier island in North Carolina. To better understand hotspot dynamics and the potential relationship to the geologic framework in which they occur, the surf zone between Duck and Bodie Island was surveyed in June 2002 as part of a research effort supported by the U.S. Geological Survey and U.S. Army Corps of Engineers. Swath bathymetry, sidescan sonar, and chirp seismic were used to characterize a region 40 km long and1 km wide. Hotspot locations were pinpointed using standard deviation values for shoreline position as determined by monthly SWASH buggy surveys of the mean high water contour between October 1999 and September 2002. Observational data and sidescan images were mapped to delineate regions of surficial sediment distributions, and regions of interest were ground-truthed via grab samples or visual inspection. General kilometer-scale correlation between acoustic backscatter and high shoreline standard deviation is evident. Acoustic returns are uniform in a region of Duck where standard deviation is low, but backscatter is patchy around the Kitty Hawk hotspot, where standard deviation is higher. Based on ground-truthing of an area further north, these patches are believed to be an older ravinement surface of fine sediment. More detailed analyses of the correlation between acoustic data, standard deviation, and hotspot locations will be presented. Future work will include integration of seismic, bathymetric, and sidescan data to better understand the links between sub-bottom geology, temporal changes in surficial sediments, surf-zone sediment budgets, and short-term changes in shoreline position and morphology.
Preliminary analysis of hot spot factors in an advanced reactor for space electric power systems
NASA Technical Reports Server (NTRS)
Lustig, P. H.; Holms, A. G.; Davison, H. W.
1973-01-01
The maximum fuel pin temperature for nominal operation in an advanced power reactor is 1370 K. Because of possible nitrogen embrittlement of the clad, the fuel temperature was limited to 1622 K. Assuming simultaneous occurrence of the most adverse conditions a deterministic analysis gave a maximum fuel temperature of 1610 K. A statistical analysis, using a synthesized estimate of the standard deviation for the highest fuel pin temperature, showed probabilities of 0.015 of that pin exceeding the temperature limit by the distribution free Chebyshev inequality and virtually nil assuming a normal distribution. The latter assumption gives a 1463 K maximum temperature at 3 standard deviations, the usually assumed cutoff. Further, the distribution and standard deviation of the fuel-clad gap are the most significant contributions to the uncertainty in the fuel temperature.
Influence of eye micromotions on spatially resolved refractometry
NASA Astrophysics Data System (ADS)
Chyzh, Igor H.; Sokurenko, Vyacheslav M.; Osipova, Irina Y.
2001-01-01
The influence eye micromotions on the accuracy of estimation of Zernike coefficients form eye transverse aberration measurements was investigated. By computer modeling, the following found eye aberrations have been examined: defocusing, primary astigmatism, spherical aberration of the 3rd and the 5th orders, as well as their combinations. It was determined that the standard deviation of estimated Zernike coefficients is proportional to the standard deviation of angular eye movements. Eye micromotions cause the estimation errors of Zernike coefficients of present aberrations and produce the appearance of Zernike coefficients of aberrations, absent in the eye. When solely defocusing is present, the biggest errors, cased by eye micromotions, are obtained for aberrations like coma and astigmatism. In comparison with other aberrations, spherical aberration of the 3rd and the 5th orders evokes the greatest increase of the standard deviation of other Zernike coefficients.
Barth, Nancy A.; Veilleux, Andrea G.
2012-01-01
The U.S. Geological Survey (USGS) is currently updating at-site flood frequency estimates for USGS streamflow-gaging stations in the desert region of California. The at-site flood-frequency analysis is complicated by short record lengths (less than 20 years is common) and numerous zero flows/low outliers at many sites. Estimates of the three parameters (mean, standard deviation, and skew) required for fitting the log Pearson Type 3 (LP3) distribution are likely to be highly unreliable based on the limited and heavily censored at-site data. In a generalization of the recommendations in Bulletin 17B, a regional analysis was used to develop regional estimates of all three parameters (mean, standard deviation, and skew) of the LP3 distribution. A regional skew value of zero from a previously published report was used with a new estimated mean squared error (MSE) of 0.20. A weighted least squares (WLS) regression method was used to develop both a regional standard deviation and a mean model based on annual peak-discharge data for 33 USGS stations throughout California’s desert region. At-site standard deviation and mean values were determined by using an expected moments algorithm (EMA) method for fitting the LP3 distribution to the logarithms of annual peak-discharge data. Additionally, a multiple Grubbs-Beck (MGB) test, a generalization of the test recommended in Bulletin 17B, was used for detecting multiple potentially influential low outliers in a flood series. The WLS regression found that no basin characteristics could explain the variability of standard deviation. Consequently, a constant regional standard deviation model was selected, resulting in a log-space value of 0.91 with a MSE of 0.03 log units. Yet drainage area was found to be statistically significant at explaining the site-to-site variability in mean. The linear WLS regional mean model based on drainage area had a Pseudo- 2 R of 51 percent and a MSE of 0.32 log units. The regional parameter estimates were then used to develop a set of equations for estimating flows with 50-, 20-, 10-, 4-, 2-, 1-, 0.5-, and 0.2-percent annual exceedance probabilities for ungaged basins. The final equations are functions of drainage area.Average standard errors of prediction for these regression equations range from 214.2 to 856.2 percent.
Khachatryan, Vardan
2015-08-27
A first search is reported for a standard model Higgs boson (H) that is produced through vector boson fusion and decays to a bottom-quark pair. Two data samples, corresponding to integrated luminosities of 19.8 fb -1 and 18.3 fb -1 of proton-proton collisions at √s=8 TeV were selected for this channel at the CERN LHC. The observed significance in these data samples for a H→more » $$\\mathrm{b\\bar{b}}$$ signal at a mass of 125 GeV is 2.2 standard deviations, while the expected significance is 0.8 standard deviations. The fitted signal strength μ=σ/σ SM=2.8 +1.6 -1.4. The combination of this result with other CMS searches for the Higgs boson decaying to a b-quark pair yields a signal strength of 1.0±0.4, corresponding to a signal significance of 2.6 standard deviations for a Higgs boson mass of 125 GeV.« less
Zarbo, Richard J; Copeland, Jacqueline R; Varney, Ruan C
2017-10-01
To develop a business subsystem fulfilling International Organization for Standardization 15189 nonconformance management regulatory standard, facilitating employee engagement in problem identification and resolution to effect quality improvement and risk mitigation. From 2012 to 2016, the integrated laboratories of the Henry Ford Health System used a quality technical team to develop and improve a management subsystem designed to identify, track, trend, and summarize nonconformances based on frequency, risk, and root cause for elimination at the level of the work. Programmatic improvements and training resulted in markedly increased documentation culminating in 71,641 deviations in 2016 classified by a taxonomy of 281 defect types into preanalytic (74.8%), analytic (23.6%), and postanalytic (1.6%) testing phases. The top 10 deviations accounted for 55,843 (78%) of the total. Deviation management is a key subsystem of managers' standard work whereby knowledge of nonconformities assists in directing corrective actions and continuous improvements that promote consistent execution and higher levels of performance. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
[Determination of acetochlor and oxyfluorfen by capillary gas chromatography].
Xiang, Wen-Sheng; Wang, Xiang-Jing; Wang, Jing; Wang, Qing
2002-09-01
A method is described for the determination of acetochlor and oxyfluorfen by capillary gas chromatography with FID and an SE-30 capillary column (60 m x 0.53 mm i. d., 1.5 microm), using dibutyl phthalate as the internal standard. The standard deviations for acetochlor and oxyfluorfen concentration(mass fraction) were 0.44% and 0.47% respectively. The relative standard deviations for acetochlor and oxyfluorfen were 0.79% and 0.88% and the average recoveries for acetochlor and oxyfluorfen were 99.3% and 101.1% respectively. The method is simple, rapid and accurate.
U.S. Navy Marine Climatic Atlas of the World. Volume IX. World-Wide Means and Standard Deviations
1981-10-01
TITLE (..d SobtII,) S. TYPE OF REPORT & PERIOD COVERED U. S. Navy Marine Climatic Atlas of the World Volume IX World-wide Means and Standard Reference...Ives the best estimate of the population standard deviations. The means, , are com~nuted from: EX IIN I 90 80 70 60" 50’ 40, 30 20 10 0 1070 T- VErr ...or 10%, whichever is greater Since the mean ice limit approximates the minus two de l temperature isopleth, this analyzed lower limit was Wave Heights
The normalization of deviance in healthcare delivery
Banja, John
2009-01-01
Many serious medical errors result from violations of recognized standards of practice. Over time, even egregious violations of standards of practice may become “normalized” in healthcare delivery systems. This article describes what leads to this normalization and explains why flagrant practice deviations can persist for years, despite the importance of the standards at issue. This article also provides recommendations to aid healthcare organizations in identifying and managing unsafe practice deviations before they become normalized and pose genuine risks to patient safety, quality care, and employee morale. PMID:20161685
Observation of the Higgs boson decay to a pair of τ leptons with the CMS detector
NASA Astrophysics Data System (ADS)
Sirunyan, A. M.; Tumasyan, A.; Adam, W.; Ambrogi, F.; Asilar, E.; Bergauer, T.; Brandstetter, J.; Brondolin, E.; Dragicevic, M.; Erö, J.; Flechl, M.; Friedl, M.; Frühwirth, R.; Ghete, V. M.; Grossmann, J.; Hrubec, J.; Jeitler, M.; König, A.; Krammer, N.; Krätschmer, I.; Liko, D.; Madlener, T.; Mikulec, I.; Pree, E.; Rabady, D.; Rad, N.; Rohringer, H.; Schieck, J.; Schöfbeck, R.; Spanring, M.; Spitzbart, D.; Waltenberger, W.; Wittmann, J.; Wulz, C.-E.; Zarucki, M.; Chekhovsky, V.; Mossolov, V.; Suarez Gonzalez, J.; De Wolf, E. A.; Di Croce, D.; Janssen, X.; Lauwers, J.; Van Haevermaet, H.; Van Mechelen, P.; Van Remortel, N.; Abu Zeid, S.; Blekman, F.; D'Hondt, J.; De Bruyn, I.; De Clercq, J.; Deroover, K.; Flouris, G.; Lontkovskyi, D.; Lowette, S.; Moortgat, S.; Moreels, L.; Python, Q.; Skovpen, K.; Tavernier, S.; Van Doninck, W.; Van Mulders, P.; Van Parijs, I.; Beghin, D.; Brun, H.; Clerbaux, B.; De Lentdecker, G.; Delannoy, H.; Fasanella, G.; Favart, L.; Goldouzian, R.; Grebenyuk, A.; Karapostoli, G.; Lenzi, T.; Luetic, J.; Maerschalk, T.; Marinov, A.; Randle-conde, A.; Seva, T.; Vander Velde, C.; Vanlaer, P.; Vannerom, D.; Yonamine, R.; Zenoni, F.; Zhang, F.; Cimmino, A.; Cornelis, T.; Dobur, D.; Fagot, A.; Gul, M.; Khvastunov, I.; Poyraz, D.; Roskas, C.; Salva, S.; Tytgat, M.; Verbeke, W.; Zaganidis, N.; Bakhshiansohi, H.; Bondu, O.; Brochet, S.; Bruno, G.; Caputo, C.; Caudron, A.; De Visscher, S.; Delaere, C.; Delcourt, M.; Francois, B.; Giammanco, A.; Jafari, A.; Komm, M.; Krintiras, G.; Lemaitre, V.; Magitteri, A.; Mertens, A.; Musich, M.; Piotrzkowski, K.; Quertenmont, L.; Vidal Marono, M.; Wertz, S.; Beliy, N.; Aldá Júnior, W. L.; Alves, F. L.; Alves, G. A.; Brito, L.; Correa Martins Junior, M.; Hensel, C.; Moraes, A.; Pol, M. E.; Rebello Teles, P.; Belchior Batista Das Chagas, E.; Carvalho, W.; Chinellato, J.; Coelho, E.; Custódio, A.; Da Costa, E. M.; Da Silveira, G. G.; De Jesus Damiao, D.; Fonseca De Souza, S.; Huertas Guativa, L. M.; Malbouisson, H.; Melo De Almeida, M.; Mora Herrera, C.; Mundim, L.; Nogima, H.; Santoro, A.; Sznajder, A.; Tonelli Manganote, E. J.; Torres Da Silva De Araujo, F.; Vilela Pereira, A.; Ahuja, S.; Bernardes, C. A.; Fernandez Perez Tomei, T. R.; Gregores, E. M.; Mercadante, P. G.; Novaes, S. F.; Padula, Sandra S.; Romero Abad, D.; Ruiz Vargas, J. C.; Aleksandrov, A.; Hadjiiska, R.; Iaydjiev, P.; Misheva, M.; Rodozov, M.; Shopova, M.; Stoykova, S.; Sultanov, G.; Dimitrov, A.; Glushkov, I.; Litov, L.; Pavlov, B.; Petkov, P.; Fang, W.; Gao, X.; Ahmad, M.; Bian, J. G.; Chen, G. M.; Chen, H. S.; Chen, M.; Chen, Y.; Jiang, C. H.; Leggat, D.; Liao, H.; Liu, Z.; Romeo, F.; Shaheen, S. M.; Spiezia, A.; Tao, J.; Wang, C.; Wang, Z.; Yazgan, E.; Zhang, H.; Zhang, S.; Zhao, J.; Ban, Y.; Chen, G.; Li, Q.; Liu, S.; Mao, Y.; Qian, S. J.; Wang, D.; Xu, Z.; Avila, C.; Cabrera, A.; Chaparro Sierra, L. F.; Florez, C.; González Hernández, C. F.; Ruiz Alvarez, J. D.; Courbon, B.; Godinovic, N.; Lelas, D.; Puljak, I.; Ribeiro Cipriano, P. M.; Sculac, T.; Antunovic, Z.; Kovac, M.; Brigljevic, V.; Ferencek, D.; Kadija, K.; Mesic, B.; Starodumov, A.; Susa, T.; Ather, M. W.; Attikis, A.; Mavromanolakis, G.; Mousa, J.; Nicolaou, C.; Ptochos, F.; Razis, P. A.; Rykaczewski, H.; Finger, M.; Finger, M.; Carrera Jarrin, E.; Assran, Y.; Elgammal, S.; Mahrous, A.; Dewanjee, R. K.; Kadastik, M.; Perrini, L.; Raidal, M.; Tiko, A.; Veelken, C.; Eerola, P.; Pekkanen, J.; Voutilainen, M.; Härkönen, J.; Järvinen, T.; Karimäki, V.; Kinnunen, R.; Lampén, T.; Lassila-Perini, K.; Lehti, S.; Lindén, T.; Luukka, P.; Tuominen, E.; Tuominiemi, J.; Tuovinen, E.; Talvitie, J.; Tuuva, T.; Besancon, M.; Couderc, F.; Dejardin, M.; Denegri, D.; Faure, J. L.; Ferri, F.; Ganjour, S.; Ghosh, S.; Givernaud, A.; Gras, P.; Hamel de Monchenault, G.; Jarry, P.; Kucher, I.; Locci, E.; Machet, M.; Malcles, J.; Negro, G.; Rander, J.; Rosowsky, A.; Sahin, M. Ö.; Titov, M.; Abdulsalam, A.; Amendola, C.; Antropov, I.; Baffioni, S.; Beaudette, F.; Busson, P.; Cadamuro, L.; Charlot, C.; Granier de Cassagnac, R.; Jo, M.; Lisniak, S.; Lobanov, A.; Martin Blanco, J.; Nguyen, M.; Ochando, C.; Ortona, G.; Paganini, P.; Pigard, P.; Salerno, R.; Sauvan, J. B.; Sirois, Y.; Stahl Leiton, A. G.; Strebler, T.; Yilmaz, Y.; Zabi, A.; Zghiche, A.; Agram, J.-L.; Andrea, J.; Bloch, D.; Brom, J.-M.; Buttignol, M.; Chabert, E. C.; Chanon, N.; Collard, C.; Conte, E.; Coubez, X.; Fontaine, J.-C.; Gelé, D.; Goerlach, U.; Jansová, M.; Le Bihan, A.-C.; Tonon, N.; Van Hove, P.; Gadrat, S.; Beauceron, S.; Bernet, C.; Boudoul, G.; Chierici, R.; Contardo, D.; Depasse, P.; El Mamouni, H.; Fay, J.; Finco, L.; Gascon, S.; Gouzevitch, M.; Grenier, G.; Ille, B.; Lagarde, F.; Laktineh, I. B.; Lethuillier, M.; Mirabito, L.; Pequegnot, A. L.; Perries, S.; Popov, A.; Sordini, V.; Vander Donckt, M.; Viret, S.; Khvedelidze, A.; Tsamalaidze, Z.; Autermann, C.; Feld, L.; Kiesel, M. K.; Klein, K.; Lipinski, M.; Preuten, M.; Schomakers, C.; Schulz, J.; Verlage, T.; Zhukov, V.; Albert, A.; Dietz-Laursonn, E.; Duchardt, D.; Endres, M.; Erdmann, M.; Erdweg, S.; Esch, T.; Fischer, R.; Güth, A.; Hamer, M.; Hebbeker, T.; Heidemann, C.; Hoepfner, K.; Knutzen, S.; Merschmeyer, M.; Meyer, A.; Millet, P.; Mukherjee, S.; Pook, T.; Radziej, M.; Reithler, H.; Rieger, M.; Scheuch, F.; Teyssier, D.; Thüer, S.; Flügge, G.; Kargoll, B.; Kress, T.; Künsken, A.; Lingemann, J.; Müller, T.; Nehrkorn, A.; Nowack, A.; Pistone, C.; Pooth, O.; Stahl, A.; Aldaya Martin, M.; Arndt, T.; Asawatangtrakuldee, C.; Beernaert, K.; Behnke, O.; Behrens, U.; Bermúdez Martínez, A.; Bin Anuar, A. A.; Borras, K.; Botta, V.; Campbell, A.; Connor, P.; Contreras-Campana, C.; Costanza, F.; Diez Pardos, C.; Eckerlin, G.; Eckstein, D.; Eichhorn, T.; Eren, E.; Gallo, E.; Garay Garcia, J.; Geiser, A.; Gizhko, A.; Grados Luyando, J. M.; Grohsjean, A.; Gunnellini, P.; Guthoff, M.; Harb, A.; Hauk, J.; Hempel, M.; Jung, H.; Kalogeropoulos, A.; Kasemann, M.; Keaveney, J.; Kleinwort, C.; Korol, I.; Krücker, D.; Lange, W.; Lelek, A.; Lenz, T.; Leonard, J.; Lipka, K.; Lohmann, W.; Mankel, R.; Melzer-Pellmann, I.-A.; Meyer, A. B.; Mittag, G.; Mnich, J.; Mussgiller, A.; Ntomari, E.; Pitzl, D.; Raspereza, A.; Roland, B.; Savitskyi, M.; Saxena, P.; Shevchenko, R.; Spannagel, S.; Stefaniuk, N.; Van Onsem, G. P.; Walsh, R.; Wen, Y.; Wichmann, K.; Wissing, C.; Zenaiev, O.; Bein, S.; Blobel, V.; Centis Vignali, M.; Dreyer, T.; Garutti, E.; Gonzalez, D.; Haller, J.; Hinzmann, A.; Hoffmann, M.; Karavdina, A.; Klanner, R.; Kogler, R.; Kovalchuk, N.; Kurz, S.; Lapsien, T.; Marchesini, I.; Marconi, D.; Meyer, M.; Niedziela, M.; Nowatschin, D.; Pantaleo, F.; Peiffer, T.; Perieanu, A.; Scharf, C.; Schleper, P.; Schmidt, A.; Schumann, S.; Schwandt, J.; Sonneveld, J.; Stadie, H.; Steinbrück, G.; Stober, F. M.; Stöver, M.; Tholen, H.; Troendle, D.; Usai, E.; Vanelderen, L.; Vanhoefer, A.; Vormwald, B.; Akbiyik, M.; Barth, C.; Baur, S.; Butz, E.; Caspart, R.; Chwalek, T.; Colombo, F.; De Boer, W.; Dierlamm, A.; Freund, B.; Friese, R.; Giffels, M.; Haitz, D.; Hartmann, F.; Heindl, S. M.; Husemann, U.; Kassel, F.; Kudella, S.; Mildner, H.; Mozer, M. U.; Müller, Th.; Plagge, M.; Quast, G.; Rabbertz, K.; Schröder, M.; Shvetsov, I.; Sieber, G.; Simonis, H. J.; Ulrich, R.; Wayand, S.; Weber, M.; Weiler, T.; Williamson, S.; Wöhrmann, C.; Wolf, R.; Anagnostou, G.; Daskalakis, G.; Geralis, T.; Giakoumopoulou, V. A.; Kyriakis, A.; Loukas, D.; Topsis-Giotis, I.; Karathanasis, G.; Kesisoglou, S.; Panagiotou, A.; Saoulidou, N.; Kousouris, K.; Evangelou, I.; Foudas, C.; Kokkas, P.; Mallios, S.; Manthos, N.; Papadopoulos, I.; Paradas, E.; Strologas, J.; Triantis, F. A.; Csanad, M.; Filipovic, N.; Pasztor, G.; Veres, G. I.; Bencze, G.; Hajdu, C.; Horvath, D.; Hunyadi, Á.; Sikler, F.; Veszpremi, V.; Zsigmond, A. J.; Beni, N.; Czellar, S.; Karancsi, J.; Makovec, A.; Molnar, J.; Szillasi, Z.; Bartók, M.; Raics, P.; Trocsanyi, Z. L.; Ujvari, B.; Choudhury, S.; Komaragiri, J. R.; Bahinipati, S.; Bhowmik, S.; Mal, P.; Mandal, K.; Nayak, A.; Sahoo, D. K.; Sahoo, N.; Swain, S. K.; Bansal, S.; Beri, S. B.; Bhatnagar, V.; Chawla, R.; Dhingra, N.; Kalsi, A. K.; Kaur, A.; Kaur, M.; Kumar, R.; Kumari, P.; Mehta, A.; Singh, J. B.; Walia, G.; Kumar, Ashok; Shah, Aashaq; Bhardwaj, A.; Chauhan, S.; Choudhary, B. C.; Garg, R. B.; Keshri, S.; Kumar, A.; Malhotra, S.; Naimuddin, M.; Ranjan, K.; Sharma, R.; Bhardwaj, R.; Bhattacharya, R.; Bhattacharya, S.; Bhawandeep, U.; Dey, S.; Dutt, S.; Dutta, S.; Ghosh, S.; Majumdar, N.; Modak, A.; Mondal, K.; Mukhopadhyay, S.; Nandan, S.; Purohit, A.; Roy, A.; Roy, D.; Roy Chowdhury, S.; Sarkar, S.; Sharan, M.; Thakur, S.; Behera, P. K.; Chudasama, R.; Dutta, D.; Jha, V.; Kumar, V.; Mohanty, A. K.; Netrakanti, P. K.; Pant, L. M.; Shukla, P.; Topkar, A.; Aziz, T.; Dugad, S.; Mahakud, B.; Mitra, S.; Mohanty, G. B.; Sur, N.; Sutar, B.; Banerjee, S.; Bhattacharya, S.; Chatterjee, S.; Das, P.; Guchait, M.; Jain, Sa.; Kumar, S.; Maity, M.; Majumder, G.; Mazumdar, K.; Sarkar, T.; Wickramage, N.; Chauhan, S.; Dube, S.; Hegde, V.; Kapoor, A.; Kothekar, K.; Pandey, S.; Rane, A.; Sharma, S.; Chenarani, S.; Eskandari Tadavani, E.; Etesami, S. M.; Khakzad, M.; Mohammadi Najafabadi, M.; Naseri, M.; Paktinat Mehdiabadi, S.; Rezaei Hosseinabadi, F.; Safarzadeh, B.; Zeinali, M.; Felcini, M.; Grunewald, M.; Abbrescia, M.; Calabria, C.; Colaleo, A.; Creanza, D.; Cristella, L.; De Filippis, N.; De Palma, M.; Errico, F.; Fiore, L.; Iaselli, G.; Lezki, S.; Maggi, G.; Maggi, M.; Miniello, G.; My, S.; Nuzzo, S.; Pompili, A.; Pugliese, G.; Radogna, R.; Ranieri, A.; Selvaggi, G.; Sharma, A.; Silvestris, L.; Venditti, R.; Verwilligen, P.; Abbiendi, G.; Battilana, C.; Bonacorsi, D.; Braibant-Giacomelli, S.; Campanini, R.; Capiluppi, P.; Castro, A.; Cavallo, F. R.; Chhibra, S. S.; Codispoti, G.; Cuffiani, M.; Dallavalle, G. M.; Fabbri, F.; Fanfani, A.; Fasanella, D.; Giacomelli, P.; Grandi, C.; Guiducci, L.; Marcellini, S.; Masetti, G.; Montanari, A.; Navarria, F. L.; Perrotta, A.; Rossi, A. M.; Rovelli, T.; Siroli, G. P.; Tosi, N.; Albergo, S.; Costa, S.; Di Mattia, A.; Giordano, F.; Potenza, R.; Tricomi, A.; Tuve, C.; Barbagli, G.; Chatterjee, K.; Ciulli, V.; Civinini, C.; D'Alessandro, R.; Focardi, E.; Lenzi, P.; Meschini, M.; Paoletti, S.; Russo, L.; Sguazzoni, G.; Strom, D.; Viliani, L.; Benussi, L.; Bianco, S.; Fabbri, F.; Piccolo, D.; Primavera, F.; Calvelli, V.; Ferro, F.; Robutti, E.; Tosi, S.; Benaglia, A.; Brianza, L.; Brivio, F.; Ciriolo, V.; Dinardo, M. E.; Fiorendi, S.; Gennai, S.; Ghezzi, A.; Govoni, P.; Malberti, M.; Malvezzi, S.; Manzoni, R. A.; Menasce, D.; Moroni, L.; Paganoni, M.; Pauwels, K.; Pedrini, D.; Pigazzini, S.; Ragazzi, S.; Redaelli, N.; Tabarelli de Fatis, T.; Buontempo, S.; Cavallo, N.; Di Guida, S.; Fabozzi, F.; Fienga, F.; Iorio, A. O. M.; Khan, W. A.; Lista, L.; Meola, S.; Paolucci, P.; Sciacca, C.; Thyssen, F.; Azzi, P.; Bacchetta, N.; Benato, L.; Bisello, D.; Boletti, A.; Bragagnolo, A.; Carlin, R.; Carvalho Antunes De Oliveira, A.; Checchia, P.; Dall'Osso, M.; De Castro Manzano, P.; Dorigo, T.; Dosselli, U.; Gasparini, F.; Gasparini, U.; Lacaprara, S.; Lujan, P.; Margoni, M.; Meneguzzo, A. T.; Pozzobon, N.; Ronchese, P.; Rossin, R.; Simonetto, F.; Torassa, E.; Ventura, S.; Zanetti, M.; Zotto, P.; Braghieri, A.; Magnani, A.; Montagna, P.; Ratti, S. P.; Re, V.; Ressegotti, M.; Riccardi, C.; Salvini, P.; Vai, I.; Vitulo, P.; Alunni Solestizi, L.; Biasini, M.; Bilei, G. M.; Cecchi, C.; Ciangottini, D.; Fanò, L.; Lariccia, P.; Leonardi, R.; Manoni, E.; Mantovani, G.; Mariani, V.; Menichelli, M.; Rossi, A.; Santocchia, A.; Spiga, D.; Androsov, K.; Azzurri, P.; Bagliesi, G.; Boccali, T.; Borrello, L.; Castaldi, R.; Ciocci, M. A.; Dell'Orso, R.; Fedi, G.; Giannini, L.; Giassi, A.; Grippo, M. T.; Ligabue, F.; Lomtadze, T.; Manca, E.; Mandorli, G.; Martini, L.; Messineo, A.; Palla, F.; Rizzi, A.; Savoy-Navarro, A.; Spagnolo, P.; Tenchini, R.; Tonelli, G.; Venturi, A.; Verdini, P. G.; Barone, L.; Cavallari, F.; Cipriani, M.; Daci, N.; Del Re, D.; Di Marco, E.; Diemoz, M.; Gelli, S.; Longo, E.; Margaroli, F.; Marzocchi, B.; Meridiani, P.; Organtini, G.; Paramatti, R.; Preiato, F.; Rahatlou, S.; Rovelli, C.; Santanastasio, F.; Amapane, N.; Arcidiacono, R.; Argiro, S.; Arneodo, M.; Bartosik, N.; Bellan, R.; Biino, C.; Cartiglia, N.; Cenna, F.; Costa, M.; Covarelli, R.; Degano, A.; Demaria, N.; Kiani, B.; Mariotti, C.; Maselli, S.; Migliore, E.; Monaco, V.; Monteil, E.; Monteno, M.; Obertino, M. M.; Pacher, L.; Pastrone, N.; Pelliccioni, M.; Pinna Angioni, G. L.; Ravera, F.; Romero, A.; Ruspa, M.; Sacchi, R.; Shchelina, K.; Sola, V.; Solano, A.; Staiano, A.; Traczyk, P.; Belforte, S.; Casarsa, M.; Cossutti, F.; Della Ricca, G.; Zanetti, A.; Kim, D. H.; Kim, G. N.; Kim, M. S.; Lee, J.; Lee, S.; Lee, S. W.; Moon, C. S.; Oh, Y. D.; Sekmen, S.; Son, D. C.; Yang, Y. C.; Lee, A.; Kim, H.; Moon, D. H.; Oh, G.; Brochero Cifuentes, J. A.; Goh, J.; Kim, T. J.; Cho, S.; Choi, S.; Go, Y.; Gyun, D.; Ha, S.; Hong, B.; Jo, Y.; Kim, Y.; Lee, K.; Lee, K. S.; Lee, S.; Lim, J.; Park, S. K.; Roh, Y.; Almond, J.; Kim, J.; Kim, J. S.; Lee, H.; Lee, K.; Nam, K.; Oh, S. B.; Radburn-Smith, B. C.; Seo, S. h.; Yang, U. K.; Yoo, H. D.; Yu, G. B.; Choi, M.; Kim, H.; Kim, J. H.; Lee, J. S. H.; Park, I. C.; Choi, Y.; Hwang, C.; Lee, J.; Yu, I.; Dudenas, V.; Juodagalvis, A.; Vaitkus, J.; Ahmed, I.; Ibrahim, Z. A.; Md Ali, M. A. B.; Mohamad Idris, F.; Wan Abdullah, W. A. T.; Yusli, M. N.; Zolkapli, Z.; Reyes-Almanza, R.; Ramirez-Sanchez, G.; Duran-Osuna, M. C.; Castilla-Valdez, H.; De La Cruz-Burelo, E.; Heredia-De La Cruz, I.; Rabadan-Trejo, R. I.; Lopez-Fernandez, R.; Mejia Guisao, J.; Sanchez-Hernandez, A.; Carrillo Moreno, S.; Oropeza Barrera, C.; Vazquez Valencia, F.; Pedraza, I.; Salazar Ibarguen, H. A.; Uribe Estrada, C.; Morelos Pineda, A.; Krofcheck, D.; Butler, P. H.; Ahmad, A.; Ahmad, M.; Hassan, Q.; Hoorani, H. R.; Saddique, A.; Shah, M. A.; Shoaib, M.; Waqas, M.; Bialkowska, H.; Bluj, M.; Boimska, B.; Frueboes, T.; Górski, M.; Kazana, M.; Nawrocki, K.; Szleper, M.; Zalewski, P.; Bunkowski, K.; Byszuk, A.; Doroba, K.; Kalinowski, A.; Konecki, M.; Krolikowski, J.; Misiura, M.; Olszewski, M.; Pyskir, A.; Walczak, M.; Bargassa, P.; Beirão Da Cruz E Silva, C.; Di Francesco, A.; Faccioli, P.; Galinhas, B.; Gallinaro, M.; Hollar, J.; Leonardo, N.; Lloret Iglesias, L.; Nemallapudi, M. V.; Seixas, J.; Strong, G.; Toldaiev, O.; Vadruccio, D.; Varela, J.; Afanasiev, S.; Bunin, P.; Gavrilenko, M.; Golutvin, I.; Gorbunov, I.; Kamenev, A.; Karjavin, V.; Lanev, A.; Malakhov, A.; Matveev, V.; Palichik, V.; Perelygin, V.; Shmatov, S.; Shulha, S.; Skatchkov, N.; Smirnov, V.; Voytishin, N.; Zarubin, A.; Ivanov, Y.; Kim, V.; Kuznetsova, E.; Levchenko, P.; Murzin, V.; Oreshkin, V.; Smirnov, I.; Sulimov, V.; Uvarov, L.; Vavilov, S.; Vorobyev, A.; Andreev, Yu.; Dermenev, A.; Gninenko, S.; Golubev, N.; Karneyeu, A.; Kirsanov, M.; Krasnikov, N.; Pashenkov, A.; Tlisov, D.; Toropin, A.; Epshteyn, V.; Gavrilov, V.; Lychkovskaya, N.; Popov, V.; Pozdnyakov, I.; Safronov, G.; Spiridonov, A.; Stepennov, A.; Toms, M.; Vlasov, E.; Zhokin, A.; Aushev, T.; Bylinkin, A.; Chadeeva, M.; Parygin, P.; Philippov, D.; Polikarpov, S.; Popova, E.; Rusinov, V.; Andreev, V.; Azarkin, M.; Dremin, I.; Kirakosyan, M.; Terkulov, A.; Baskakov, A.; Belyaev, A.; Boos, E.; Bunichev, V.; Dubinin, M.; Dudko, L.; Ershov, A.; Gribushin, A.; Klyukhin, V.; Kodolova, O.; Lokhtin, I.; Miagkov, I.; Obraztsov, S.; Petrushanko, S.; Savrin, V.; Blinov, V.; Skovpen, Y.; Shtol, D.; Azhgirey, I.; Bayshev, I.; Bitioukov, S.; Elumakhov, D.; Kachanov, V.; Kalinin, A.; Konstantinov, D.; Petrov, V.; Ryutin, R.; Sobol, A.; Troshin, S.; Tyurin, N.; Uzunian, A.; Volkov, A.; Adzic, P.; Cirkovic, P.; Devetak, D.; Dordevic, M.; Milosevic, J.; Rekovic, V.; Alcaraz Maestre, J.; Barrio Luna, M.; Cerrada, M.; Colino, N.; De La Cruz, B.; Delgado Peris, A.; Escalante Del Valle, A.; Fernandez Bedoya, C.; Fernández Ramos, J. P.; Flix, J.; Fouz, M. C.; Garcia-Abia, P.; Gonzalez Lopez, O.; Goy Lopez, S.; Hernandez, J. M.; Josa, M. I.; Moran, D.; Pérez-Calero Yzquierdo, A.; Puerta Pelayo, J.; Quintario Olmeda, A.; Redondo, I.; Romero, L.; Soares, M. S.; Álvarez Fernández, A.; de Trocóniz, J. F.; Missiroli, M.; Cuevas, J.; Erice, C.; Fernandez Menendez, J.; Gonzalez Caballero, I.; González Fernández, J. R.; Palencia Cortezon, E.; Sanchez Cruz, S.; Vischia, P.; Vizan Garcia, J. M.; Cabrillo, I. J.; Calderon, A.; Chazin Quero, B.; Curras, E.; Duarte Campderros, J.; Fernandez, M.; Garcia-Ferrero, J.; Gomez, G.; Lopez Virto, A.; Marco, J.; Martinez Rivero, C.; Martinez Ruiz del Arbol, P.; Matorras, F.; Piedra Gomez, J.; Rodrigo, T.; Ruiz-Jimeno, A.; Scodellaro, L.; Trevisani, N.; Vila, I.; Vilar Cortabitarte, R.; Abbaneo, D.; Auffray, E.; Baillon, P.; Ball, A. H.; Barney, D.; Bianco, M.; Bloch, P.; Bocci, A.; Botta, C.; Camporesi, T.; Castello, R.; Cepeda, M.; Cerminara, G.; Chapon, E.; Chen, Y.; d'Enterria, D.; Dabrowski, A.; Daponte, V.; David, A.; De Gruttola, M.; De Roeck, A.; Dobson, M.; Dorney, B.; du Pree, T.; Dünser, M.; Dupont, N.; Elliott-Peisert, A.; Everaerts, P.; Fallavollita, F.; Franzoni, G.; Fulcher, J.; Funk, W.; Gigi, D.; Gilbert, A.; Gill, K.; Glege, F.; Gulhan, D.; Harris, P.; Hegeman, J.; Innocente, V.; Janot, P.; Karacheban, O.; Kieseler, J.; Kirschenmann, H.; Knünz, V.; Kornmayer, A.; Kortelainen, M. J.; Krammer, M.; Lange, C.; Lecoq, P.; Lourenço, C.; Lucchini, M. T.; Malgeri, L.; Mannelli, M.; Martelli, A.; Meijers, F.; Merlin, J. A.; Mersi, S.; Meschi, E.; Milenovic, P.; Moortgat, F.; Mulders, M.; Neugebauer, H.; Ngadiuba, J.; Orfanelli, S.; Orsini, L.; Pape, L.; Perez, E.; Peruzzi, M.; Petrilli, A.; Petrucciani, G.; Pfeiffer, A.; Pierini, M.; Racz, A.; Reis, T.; Rolandi, G.; Rovere, M.; Sakulin, H.; Schäfer, C.; Schwick, C.; Seidel, M.; Selvaggi, M.; Sharma, A.; Silva, P.; Sphicas, P.; Stakia, A.; Steggemann, J.; Stoye, M.; Tosi, M.; Treille, D.; Triossi, A.; Tsirou, A.; Veckalns, V.; Verweij, M.; Zeuner, W. D.; Bertl, W.; Caminada, L.; Deiters, K.; Erdmann, W.; Horisberger, R.; Ingram, Q.; Kaestli, H. C.; Kotlinski, D.; Langenegger, U.; Rohe, T.; Wiederkehr, S. A.; Bäni, L.; Berger, P.; Bianchini, L.; Casal, B.; Dissertori, G.; Dittmar, M.; Donegà, M.; Grab, C.; Heidegger, C.; Hits, D.; Hoss, J.; Kasieczka, G.; Klijnsma, T.; Lustermann, W.; Mangano, B.; Marionneau, M.; Meinhard, M. T.; Meister, D.; Micheli, F.; Musella, P.; Nessi-Tedaldi, F.; Pandolfi, F.; Pata, J.; Pauss, F.; Perrin, G.; Perrozzi, L.; Quittnat, M.; Reichmann, M.; Schönenberger, M.; Shchutska, L.; Tavolaro, V. R.; Theofilatos, K.; Vesterbacka Olsson, M. L.; Wallny, R.; Zhu, D. H.; Aarrestad, T. K.; Amsler, C.; Canelli, M. F.; De Cosa, A.; Del Burgo, R.; Donato, S.; Galloni, C.; Hreus, T.; Kilminster, B.; Pinna, D.; Rauco, G.; Robmann, P.; Salerno, D.; Seitz, C.; Takahashi, Y.; Zucchetta, A.; Candelise, V.; Doan, T. H.; Jain, Sh.; Khurana, R.; Kuo, C. M.; Lin, W.; Pozdnyakov, A.; Yu, S. S.; Kumar, Arun; Chang, P.; Chao, Y.; Chen, K. F.; Chen, P. H.; Fiori, F.; Hsiung, Y.; Liu, Y. F.; Lu, R.-S.; Paganis, E.; Psallidas, A.; Steen, A.; Tsai, J. f.; Asavapibhop, B.; Kovitanggoon, K.; Singh, G.; Srimanobhas, N.; Boran, F.; Cerci, S.; Damarseckin, S.; Demiroglu, Z. S.; Dozen, C.; Dumanoglu, I.; Girgis, S.; Gokbulut, G.; Guler, Y.; Hos, I.; Kangal, E. E.; Kara, O.; Kayis Topaksu, A.; Kiminsu, U.; Oglakci, M.; Onengut, G.; Ozdemir, K.; Sunar Cerci, D.; Tali, B.; Turkcapar, S.; Zorbakir, I. S.; Zorbilmez, C.; Bilin, B.; Karapinar, G.; Ocalan, K.; Yalvac, M.; Zeyrek, M.; Gülmez, E.; Kaya, M.; Kaya, O.; Tekten, S.; Yetkin, E. A.; Agaras, M. N.; Atay, S.; Cakir, A.; Cankocak, K.; Grynyov, B.; Levchuk, L.; Aggleton, R.; Ball, F.; Beck, L.; Brooke, J. J.; Burns, D.; Clement, E.; Cussans, D.; Davignon, O.; Flacher, H.; Goldstein, J.; Grimes, M.; Heath, G. P.; Heath, H. F.; Jacob, J.; Kreczko, L.; Lucas, C.; Newbold, D. M.; Paramesvaran, S.; Poll, A.; Sakuma, T.; Seif El Nasr-storey, S.; Smith, D.; Smith, V. J.; Bell, K. W.; Belyaev, A.; Brew, C.; Brown, R. M.; Calligaris, L.; Cieri, D.; Cockerill, D. J. A.; Coughlan, J. A.; Harder, K.; Harper, S.; Olaiya, E.; Petyt, D.; Shepherd-Themistocleous, C. H.; Thea, A.; Tomalin, I. R.; Williams, T.; Auzinger, G.; Bainbridge, R.; Borg, J.; Breeze, S.; Buchmuller, O.; Bundock, A.; Casasso, S.; Citron, M.; Colling, D.; Corpe, L.; Dauncey, P.; Davies, G.; De Wit, A.; Della Negra, M.; Di Maria, R.; Elwood, A.; Haddad, Y.; Hall, G.; Iles, G.; James, T.; Lane, R.; Laner, C.; Lyons, L.; Magnan, A.-M.; Malik, S.; Mastrolorenzo, L.; Matsushita, T.; Nash, J.; Nikitenko, A.; Palladino, V.; Pesaresi, M.; Raymond, D. M.; Richards, A.; Rose, A.; Scott, E.; Seez, C.; Shtipliyski, A.; Summers, S.; Tapper, A.; Uchida, K.; Vazquez Acosta, M.; Virdee, T.; Wardle, N.; Winterbottom, D.; Wright, J.; Zenz, S. C.; Cole, J. E.; Hobson, P. R.; Khan, A.; Kyberd, P.; Reid, I. D.; Symonds, P.; Teodorescu, L.; Turner, M.; Borzou, A.; Call, K.; Dittmann, J.; Hatakeyama, K.; Liu, H.; Pastika, N.; Smith, C.; Bartek, R.; Dominguez, A.; Buccilli, A.; Cooper, S. I.; Henderson, C.; Rumerio, P.; West, C.; Arcaro, D.; Avetisyan, A.; Bose, T.; Gastler, D.; Rankin, D.; Richardson, C.; Rohlf, J.; Sulak, L.; Zou, D.; Benelli, G.; Cutts, D.; Garabedian, A.; Hakala, J.; Heintz, U.; Hogan, J. M.; Kwok, K. H. M.; Laird, E.; Landsberg, G.; Mao, Z.; Narain, M.; Pazzini, J.; Piperov, S.; Sagir, S.; Syarif, R.; Yu, D.; Band, R.; Brainerd, C.; Burns, D.; Calderon De La Barca Sanchez, M.; Chertok, M.; Conway, J.; Conway, R.; Cox, P. T.; Erbacher, R.; Flores, C.; Funk, G.; Gardner, M.; Ko, W.; Lander, R.; Mclean, C.; Mulhearn, M.; Pellett, D.; Pilot, J.; Shalhout, S.; Shi, M.; Smith, J.; Stolp, D.; Tos, K.; Tripathi, M.; Wang, Z.; Bachtis, M.; Bravo, C.; Cousins, R.; Dasgupta, A.; Florent, A.; Hauser, J.; Ignatenko, M.; Mccoll, N.; Regnard, S.; Saltzberg, D.; Schnaible, C.; Valuev, V.; Bouvier, E.; Burt, K.; Clare, R.; Ellison, J.; Gary, J. W.; Ghiasi Shirazi, S. M. A.; Hanson, G.; Heilman, J.; Jandir, P.; Kennedy, E.; Lacroix, F.; Long, O. R.; Olmedo Negrete, M.; Paneva, M. I.; Shrinivas, A.; Si, W.; Wang, L.; Wei, H.; Wimpenny, S.; Yates, B. R.; Branson, J. G.; Cittolin, S.; Derdzinski, M.; Gerosa, R.; Hashemi, B.; Holzner, A.; Klein, D.; Kole, G.; Krutelyov, V.; Letts, J.; Macneill, I.; Masciovecchio, M.; Olivito, D.; Padhi, S.; Pieri, M.; Sani, M.; Sharma, V.; Simon, S.; Tadel, M.; Vartak, A.; Wasserbaech, S.; Wood, J.; Würthwein, F.; Yagil, A.; Zevi Della Porta, G.; Amin, N.; Bhandari, R.; Bradmiller-Feld, J.; Campagnari, C.; Dishaw, A.; Dutta, V.; Franco Sevilla, M.; George, C.; Golf, F.; Gouskos, L.; Gran, J.; Heller, R.; Incandela, J.; Mullin, S. D.; Ovcharova, A.; Qu, H.; Richman, J.; Stuart, D.; Suarez, I.; Yoo, J.; Anderson, D.; Bendavid, J.; Bornheim, A.; Lawhorn, J. M.; Newman, H. B.; Nguyen, T.; Pena, C.; Spiropulu, M.; Vlimant, J. R.; Xie, S.; Zhang, Z.; Zhu, R. Y.; Andrews, M. B.; Ferguson, T.; Mudholkar, T.; Paulini, M.; Russ, J.; Sun, M.; Vogel, H.; Vorobiev, I.; Weinberg, M.; Cumalat, J. P.; Ford, W. T.; Jensen, F.; Johnson, A.; Krohn, M.; Leontsinis, S.; Mulholland, T.; Stenson, K.; Wagner, S. R.; Alexander, J.; Chaves, J.; Chu, J.; Dittmer, S.; Mcdermott, K.; Mirman, N.; Patterson, J. R.; Rinkevicius, A.; Ryd, A.; Skinnari, L.; Soffi, L.; Tan, S. M.; Tao, Z.; Thom, J.; Tucker, J.; Wittich, P.; Zientek, M.; Abdullin, S.; Albrow, M.; Alyari, M.; Apollinari, G.; Apresyan, A.; Apyan, A.; Banerjee, S.; Bauerdick, L. A. T.; Beretvas, A.; Berryhill, J.; Bhat, P. C.; Bolla, G.; Burkett, K.; Butler, J. N.; Canepa, A.; Cerati, G. B.; Cheung, H. W. K.; Chlebana, F.; Cremonesi, M.; Duarte, J.; Elvira, V. D.; Freeman, J.; Gecse, Z.; Gottschalk, E.; Gray, L.; Green, D.; Grünendahl, S.; Gutsche, O.; Harris, R. M.; Hasegawa, S.; Hirschauer, J.; Hu, Z.; Jayatilaka, B.; Jindariani, S.; Johnson, M.; Joshi, U.; Klima, B.; Kreis, B.; Lammel, S.; Lincoln, D.; Lipton, R.; Liu, M.; Liu, T.; Lopes De Sá, R.; Lykken, J.; Maeshima, K.; Magini, N.; Marraffino, J. M.; Maruyama, S.; Mason, D.; McBride, P.; Merkel, P.; Mrenna, S.; Nahn, S.; O'Dell, V.; Pedro, K.; Prokofyev, O.; Rakness, G.; Ristori, L.; Schneider, B.; Sexton-Kennedy, E.; Soha, A.; Spalding, W. J.; Spiegel, L.; Stoynev, S.; Strait, J.; Strobbe, N.; Taylor, L.; Tkaczyk, S.; Tran, N. V.; Uplegger, L.; Vaandering, E. W.; Vernieri, C.; Verzocchi, M.; Vidal, R.; Wang, M.; Weber, H. A.; Whitbeck, A.; Acosta, D.; Avery, P.; Bortignon, P.; Bourilkov, D.; Brinkerhoff, A.; Carnes, A.; Carver, M.; Curry, D.; Field, R. D.; Furic, I. K.; Konigsberg, J.; Korytov, A.; Kotov, K.; Ma, P.; Matchev, K.; Mei, H.; Mitselmakher, G.; Rank, D.; Sperka, D.; Terentyev, N.; Thomas, L.; Wang, J.; Wang, S.; Yelton, J.; Joshi, Y. R.; Linn, S.; Markowitz, P.; Rodriguez, J. L.; Ackert, A.; Adams, T.; Askew, A.; Hagopian, S.; Hagopian, V.; Johnson, K. F.; Kolberg, T.; Martinez, G.; Perry, T.; Prosper, H.; Saha, A.; Santra, A.; Sharma, V.; Yohay, R.; Baarmand, M. M.; Bhopatkar, V.; Colafranceschi, S.; Hohlmann, M.; Noonan, D.; Roy, T.; Yumiceva, F.; Adams, M. R.; Apanasevich, L.; Berry, D.; Betts, R. R.; Cavanaugh, R.; Chen, X.; Evdokimov, O.; Gerber, C. E.; Hangal, D. A.; Hofman, D. J.; Jung, K.; Kamin, J.; Sandoval Gonzalez, I. D.; Tonjes, M. B.; Trauger, H.; Varelas, N.; Wang, H.; Wu, Z.; Zhang, J.; Bilki, B.; Clarida, W.; Dilsiz, K.; Durgut, S.; Gandrajula, R. P.; Haytmyradov, M.; Khristenko, V.; Merlo, J.-P.; Mermerkaya, H.; Mestvirishvili, A.; Moeller, A.; Nachtman, J.; Ogul, H.; Onel, Y.; Ozok, F.; Penzo, A.; Snyder, C.; Tiras, E.; Wetzel, J.; Yi, K.; Blumenfeld, B.; Cocoros, A.; Eminizer, N.; Fehling, D.; Feng, L.; Gritsan, A. V.; Maksimovic, P.; Roskes, J.; Sarica, U.; Swartz, M.; Xiao, M.; You, C.; Al-bataineh, A.; Baringer, P.; Bean, A.; Boren, S.; Bowen, J.; Castle, J.; Khalil, S.; Kropivnitskaya, A.; Majumder, D.; Mcbrayer, W.; Murray, M.; Royon, C.; Sanders, S.; Schmitz, E.; Tapia Takaki, J. D.; Wang, Q.; Ivanov, A.; Kaadze, K.; Maravin, Y.; Mohammadi, A.; Saini, L. K.; Skhirtladze, N.; Toda, S.; Rebassoo, F.; Wright, D.; Anelli, C.; Baden, A.; Baron, O.; Belloni, A.; Calvert, B.; Eno, S. C.; Ferraioli, C.; Hadley, N. J.; Jabeen, S.; Jeng, G. Y.; Kellogg, R. G.; Kunkle, J.; Mignerey, A. C.; Ricci-Tam, F.; Shin, Y. H.; Skuja, A.; Tonwar, S. C.; Abercrombie, D.; Allen, B.; Azzolini, V.; Barbieri, R.; Baty, A.; Bi, R.; Brandt, S.; Busza, W.; Cali, I. A.; D'Alfonso, M.; Demiragli, Z.; Gomez Ceballos, G.; Goncharov, M.; Hsu, D.; Iiyama, Y.; Innocenti, G. M.; Klute, M.; Kovalskyi, D.; Lai, Y. S.; Lee, Y.-J.; Levin, A.; Luckey, P. D.; Maier, B.; Marini, A. C.; Mcginn, C.; Mironov, C.; Narayanan, S.; Niu, X.; Paus, C.; Roland, C.; Roland, G.; Salfeld-Nebgen, J.; Stephans, G. S. F.; Tatar, K.; Velicanu, D.; Wang, J.; Wang, T. W.; Wyslouch, B.; Benvenuti, A. C.; Chatterjee, R. M.; Evans, A.; Hansen, P.; Kalafut, S.; Kubota, Y.; Lesko, Z.; Mans, J.; Nourbakhsh, S.; Ruckstuhl, N.; Rusack, R.; Turkewitz, J.; Acosta, J. G.; Oliveros, S.; Avdeeva, E.; Bloom, K.; Claes, D. R.; Fangmeier, C.; Gonzalez Suarez, R.; Kamalieddin, R.; Kravchenko, I.; Monroy, J.; Siado, J. E.; Snow, G. R.; Stieger, B.; Dolen, J.; Godshalk, A.; Harrington, C.; Iashvili, I.; Nguyen, D.; Parker, A.; Rappoccio, S.; Roozbahani, B.; Alverson, G.; Barberis, E.; Hortiangtham, A.; Massironi, A.; Morse, D. M.; Nash, D.; Orimoto, T.; Teixeira De Lima, R.; Trocino, D.; Wood, D.; Bhattacharya, S.; Charaf, O.; Hahn, K. A.; Mucia, N.; Odell, N.; Pollack, B.; Schmitt, M. H.; Sung, K.; Trovato, M.; Velasco, M.; Dev, N.; Hildreth, M.; Hurtado Anampa, K.; Jessop, C.; Karmgard, D. J.; Kellams, N.; Lannon, K.; Loukas, N.; Marinelli, N.; Meng, F.; Mueller, C.; Musienko, Y.; Planer, M.; Reinsvold, A.; Ruchti, R.; Smith, G.; Taroni, S.; Wayne, M.; Wolf, M.; Woodard, A.; Alimena, J.; Antonelli, L.; Bylsma, B.; Durkin, L. S.; Flowers, S.; Francis, B.; Hart, A.; Hill, C.; Ji, W.; Liu, B.; Luo, W.; Puigh, D.; Winer, B. L.; Wulsin, H. W.; Cooperstein, S.; Driga, O.; Elmer, P.; Hardenbrook, J.; Hebda, P.; Higginbotham, S.; Lange, D.; Luo, J.; Marlow, D.; Mei, K.; Ojalvo, I.; Olsen, J.; Palmer, C.; Piroué, P.; Stickland, D.; Tully, C.; Malik, S.; Norberg, S.; Barker, A.; Barnes, V. E.; Das, S.; Folgueras, S.; Gutay, L.; Jha, M. K.; Jones, M.; Jung, A. W.; Khatiwada, A.; Miller, D. H.; Neumeister, N.; Peng, C. C.; Schulte, J. F.; Sun, J.; Wang, F.; Xie, W.; Cheng, T.; Parashar, N.; Stupak, J.; Adair, A.; Akgun, B.; Chen, Z.; Ecklund, K. M.; Geurts, F. J. M.; Guilbaud, M.; Li, W.; Michlin, B.; Northup, M.; Padley, B. P.; Roberts, J.; Rorie, J.; Tu, Z.; Zabel, J.; Bodek, A.; de Barbaro, P.; Demina, R.; Duh, Y. t.; Ferbel, T.; Galanti, M.; Garcia-Bellido, A.; Han, J.; Hindrichs, O.; Khukhunaishvili, A.; Lo, K. H.; Tan, P.; Verzetti, M.; Ciesielski, R.; Goulianos, K.; Mesropian, C.; Agapitos, A.; Chou, J. P.; Gershtein, Y.; Gómez Espinosa, T. A.; Halkiadakis, E.; Heindl, M.; Hughes, E.; Kaplan, S.; Kunnawalkam Elayavalli, R.; Kyriacou, S.; Lath, A.; Montalvo, R.; Nash, K.; Osherson, M.; Saka, H.; Salur, S.; Schnetzer, S.; Sheffield, D.; Somalwar, S.; Stone, R.; Thomas, S.; Thomassen, P.; Walker, M.; Delannoy, A. G.; Foerster, M.; Heideman, J.; Riley, G.; Rose, K.; Spanier, S.; Thapa, K.; Bouhali, O.; Castaneda Hernandez, A.; Celik, A.; Dalchenko, M.; De Mattia, M.; Delgado, A.; Dildick, S.; Eusebi, R.; Gilmore, J.; Huang, T.; Kamon, T.; Mueller, R.; Pakhotin, Y.; Patel, R.; Perloff, A.; Perniè, L.; Rathjens, D.; Safonov, A.; Tatarinov, A.; Ulmer, K. A.; Akchurin, N.; Damgov, J.; De Guio, F.; Dudero, P. R.; Faulkner, J.; Gurpinar, E.; Kunori, S.; Lamichhane, K.; Lee, S. W.; Libeiro, T.; Peltola, T.; Undleeb, S.; Volobouev, I.; Wang, Z.; Greene, S.; Gurrola, A.; Janjam, R.; Johns, W.; Maguire, C.; Melo, A.; Ni, H.; Padeken, K.; Sheldon, P.; Tuo, S.; Velkovska, J.; Xu, Q.; Arenton, M. W.; Barria, P.; Cox, B.; Hirosky, R.; Joyce, M.; Ledovskoy, A.; Li, H.; Neu, C.; Sinthuprasith, T.; Wang, Y.; Wolfe, E.; Xia, F.; Harr, R.; Karchin, P. E.; Sturdy, J.; Zaleski, S.; Brodski, M.; Buchanan, J.; Caillol, C.; Dasu, S.; Dodd, L.; Duric, S.; Gomber, B.; Grothe, M.; Herndon, M.; Hervé, A.; Hussain, U.; Klabbers, P.; Lanaro, A.; Levine, A.; Long, K.; Loveless, R.; Pierro, G. A.; Polese, G.; Ruggles, T.; Savin, A.; Smith, N.; Smith, W. H.; Taylor, D.; Woods, N.; CMS Collaboration
2018-04-01
A measurement of the H → ττ signal strength is performed using events recorded in proton-proton collisions by the CMS experiment at the LHC in 2016 at a center-of-mass energy of 13TeV. The data set corresponds to an integrated luminosity of 35.9fb-1. The H → ττ signal is established with a significance of 4.9 standard deviations, to be compared to an expected significance of 4.7 standard deviations. The best fit of the product of the observed H → ττ signal production cross section and branching fraction is 1.09-0.26+0.27 times the standard model expectation. The combination with the corresponding measurement performed with data collected by the CMS experiment at center-of-mass energies of 7 and 8TeV leads to an observed significance of 5.9 standard deviations, equal to the expected significance. This is the first observation of Higgs boson decays to τ leptons by a single experiment.
Passive PE Sampling in Support of In Situ Remediation of Contaminated Sediments
2015-08-01
control RPD relative percent difference RSD relative standard deviation SERDP Strategic Environmental Research and Development Program SOPs...sediments from 2 stations, each at 4 PCB spike levels, for four individual congeners was 22 ± 6 % relative standard deviation ( RSD ). Also, comparison of... RSD (Table 3). However, larger congeners (e.g., congeners #153 and 180) whose approach to equilibrium is less certain, based on small fractions of
NASA Astrophysics Data System (ADS)
Mohammadian, Shahabeddin K.; Zhang, Yuwen
2015-01-01
Three dimensional transient thermal analysis of an air-cooled module that contains prismatic Li-ion cells next to a special kind of aluminum pin fin heat sink whose heights of pin fins increase linearly through the width of the channel in air flow direction was studied for thermal management of Lithium-ion battery pack. The effects of pin fins arrangements, discharge rates, inlet air flow velocities, and inlet air temperatures on the battery were investigated. The results showed that despite of heat sinks with uniform pin fin heights that increase the standard deviation of the temperature field, using this kind of pin fin heat sink compare to the heat sink without pin fins not only decreases the bulk temperature inside the battery, but also decreases the standard deviation of the temperature field inside the battery as well. Increasing the inlet air temperature leads to decreasing the standard deviation of the temperature field while increases the maximum temperature of the battery. Furthermore, increasing the inlet air velocity first increases the standard deviation of the temperature field till reaches to the maximum point, and after that decreases. Also, increasing the inlet air velocity leads to decrease in the maximum temperature of the battery.
Regression Analysis of Top of Descent Location for Idle-thrust Descents
NASA Technical Reports Server (NTRS)
Stell, Laurel; Bronsvoort, Jesper; McDonald, Greg
2013-01-01
In this paper, multiple regression analysis is used to model the top of descent (TOD) location of user-preferred descent trajectories computed by the flight management system (FMS) on over 1000 commercial flights into Melbourne, Australia. The independent variables cruise altitude, final altitude, cruise Mach, descent speed, wind, and engine type were also recorded or computed post-operations. Both first-order and second-order models are considered, where cross-validation, hypothesis testing, and additional analysis are used to compare models. This identifies the models that should give the smallest errors if used to predict TOD location for new data in the future. A model that is linear in TOD altitude, final altitude, descent speed, and wind gives an estimated standard deviation of 3.9 nmi for TOD location given the trajec- tory parameters, which means about 80% of predictions would have error less than 5 nmi in absolute value. This accuracy is better than demonstrated by other ground automation predictions using kinetic models. Furthermore, this approach would enable online learning of the model. Additional data or further knowl- edge of algorithms is necessary to conclude definitively that no second-order terms are appropriate. Possible applications of the linear model are described, including enabling arriving aircraft to fly optimized descents computed by the FMS even in congested airspace. In particular, a model for TOD location that is linear in the independent variables would enable decision support tool human-machine interfaces for which a kinetic approach would be computationally too slow.
Johnsen, David L; Emamipour, Hamidreza; Guest, Jeremy S; Rood, Mark J
2016-02-02
A life-cycle assessment (LCA) and cost analysis are presented comparing the environmental and economic impacts of using regenerative thermal oxidizer (RTO), granular activated carbon (GAC), and activated carbon fiber cloth (ACFC) systems to treat gaseous emissions from sheet-foam production. The ACFC system has the lowest operational energy consumption (i.e., 19.2, 8.7, and 3.4 TJ/year at a full-scale facility for RTO, GAC, and ACFC systems, respectively). The GAC system has the smallest environmental impacts across most impact categories for the use of electricity from select states in the United States that produce sheet foam. Monte Carlo simulations indicate the GAC and ACFC systems perform similarly (within one standard deviation) for seven of nine environmental impact categories considered and have lower impacts than the RTO for every category for the use of natural gas to produce electricity. The GAC and ACFC systems recover adequate isobutane to pay for themselves through chemical-consumption offsets, whereas the net present value of the RTO is $4.1 M (20 years, $0.001/m(3) treated). The adsorption systems are more environmentally and economically competitive than the RTO due to recovered isobutane for the production process and are recommended for resource recovery from (and treatment of) sheet-foam-production exhaust gas. Research targets for these adsorption systems should focus on increasing adsorptive capacity and saturation of GAC systems and decreasing electricity and N2 consumption of ACFC systems.
The linear sizes tolerances and fits system modernization
NASA Astrophysics Data System (ADS)
Glukhov, V. I.; Grinevich, V. A.; Shalay, V. V.
2018-04-01
The study is carried out on the urgent topic for technical products quality providing in the tolerancing process of the component parts. The aim of the paper is to develop alternatives for improving the system linear sizes tolerances and dimensional fits in the international standard ISO 286-1. The tasks of the work are, firstly, to classify as linear sizes the elements additionally linear coordinating sizes that determine the detail elements location and, secondly, to justify the basic deviation of the tolerance interval for the element's linear size. The geometrical modeling method of real details elements, the analytical and experimental methods are used in the research. It is shown that the linear coordinates are the dimensional basis of the elements linear sizes. To standardize the accuracy of linear coordinating sizes in all accuracy classes, it is sufficient to select in the standardized tolerance system only one tolerance interval with symmetrical deviations: Js for internal dimensional elements (holes) and js for external elements (shafts). The main deviation of this coordinating tolerance is the average zero deviation, which coincides with the nominal value of the coordinating size. Other intervals of the tolerance system are remained for normalizing the accuracy of the elements linear sizes with a fundamental change in the basic deviation of all tolerance intervals is the maximum deviation corresponding to the limit of the element material: EI is the lower tolerance for the of the internal elements (holes) sizes and es is the upper tolerance deviation for the outer elements (shafts) sizes. It is the sizes of the material maximum that are involved in the of the dimensional elements mating of the shafts and holes and determine the fits type.
Ishibashi, Hiroki; Takano, Masashi; Sasa, Hidenori; Furuya, Kenichi
2016-01-01
Background Placenta previa, one of the most severe obstetric complications, carries an increased risk of intraoperative massive hemorrhage. Several risk factors for intraoperative hemorrhage have been identified to date. However, the correlation between birth weight and intraoperative hemorrhage has not been investigated. Here we estimate the correlation between birth weight and the occurrence of intraoperative massive hemorrhage in placenta previa. Materials and Methods We included all 256 singleton pregnancies delivered via cesarean section at our hospital because of placenta previa between 2003 and 2015. We calculated not only measured birth weights but also standard deviation values according to the Japanese standard growth curve to adjust for differences in gestational age. We assessed the correlation between birth weight and the occurrence of intraoperative massive hemorrhage (>1500 mL blood loss). Receiver operating characteristic curves were constructed to determine the cutoff value of intraoperative massive hemorrhage. Results Of 256 pregnant women with placenta previa, 96 (38%) developed intraoperative massive hemorrhage. Receiver-operating characteristic curves revealed that the area under the curve of the combination variables between the standard deviation of birth weight and intraoperative massive hemorrhage was 0.71. The cutoff value with a sensitivity of 81.3% and specificity of 55.6% was −0.33 standard deviation. The multivariate analysis revealed that a standard deviation of >−0.33 (odds ratio, 5.88; 95% confidence interval, 3.04–12.00), need for hemostatic procedures (odds ratio, 3.31; 95% confidence interval, 1.79–6.25), and placental adhesion (odds ratio, 12.68; 95% confidence interval, 2.85–92.13) were independent risk of intraoperative massive hemorrhage. Conclusion In patients with placenta previa, a birth weight >−0.33 standard deviation was a significant risk indicator of massive hemorrhage during cesarean section. Based on this result, further studies are required to investigate whether fetal weight estimated by ultrasonography can predict hemorrhage during cesarean section in patients with placental previa. PMID:27902772
Soyama, Hiroaki; Miyamoto, Morikazu; Ishibashi, Hiroki; Takano, Masashi; Sasa, Hidenori; Furuya, Kenichi
2016-01-01
Placenta previa, one of the most severe obstetric complications, carries an increased risk of intraoperative massive hemorrhage. Several risk factors for intraoperative hemorrhage have been identified to date. However, the correlation between birth weight and intraoperative hemorrhage has not been investigated. Here we estimate the correlation between birth weight and the occurrence of intraoperative massive hemorrhage in placenta previa. We included all 256 singleton pregnancies delivered via cesarean section at our hospital because of placenta previa between 2003 and 2015. We calculated not only measured birth weights but also standard deviation values according to the Japanese standard growth curve to adjust for differences in gestational age. We assessed the correlation between birth weight and the occurrence of intraoperative massive hemorrhage (>1500 mL blood loss). Receiver operating characteristic curves were constructed to determine the cutoff value of intraoperative massive hemorrhage. Of 256 pregnant women with placenta previa, 96 (38%) developed intraoperative massive hemorrhage. Receiver-operating characteristic curves revealed that the area under the curve of the combination variables between the standard deviation of birth weight and intraoperative massive hemorrhage was 0.71. The cutoff value with a sensitivity of 81.3% and specificity of 55.6% was -0.33 standard deviation. The multivariate analysis revealed that a standard deviation of >-0.33 (odds ratio, 5.88; 95% confidence interval, 3.04-12.00), need for hemostatic procedures (odds ratio, 3.31; 95% confidence interval, 1.79-6.25), and placental adhesion (odds ratio, 12.68; 95% confidence interval, 2.85-92.13) were independent risk of intraoperative massive hemorrhage. In patients with placenta previa, a birth weight >-0.33 standard deviation was a significant risk indicator of massive hemorrhage during cesarean section. Based on this result, further studies are required to investigate whether fetal weight estimated by ultrasonography can predict hemorrhage during cesarean section in patients with placental previa.
El Beltagi, Tarek A; Bowd, Christopher; Boden, Catherine; Amini, Payam; Sample, Pamela A; Zangwill, Linda M; Weinreb, Robert N
2003-11-01
To determine the relationship between areas of glaucomatous retinal nerve fiber layer thinning identified by optical coherence tomography and areas of decreased visual field sensitivity identified by standard automated perimetry in glaucomatous eyes. Retrospective observational case series. Forty-three patients with glaucomatous optic neuropathy identified by optic disc stereo photographs and standard automated perimetry mean deviations >-8 dB were included. Participants were imaged with optical coherence tomography within 6 months of reliable standard automated perimetry testing. The location and number of optical coherence tomography clock hour retinal nerve fiber layer thickness measures outside normal limits were compared with the location and number of standard automated perimetry visual field zones outside normal limits. Further, the relationship between the deviation from normal optical coherence tomography-measured retinal nerve fiber layer thickness at each clock hour and the average pattern deviation in each visual field zone was examined by using linear regression (R(2)). The retinal nerve fiber layer areas most frequently outside normal limits were the inferior and inferior temporal regions. The least sensitive visual field zones were in the superior hemifield. Linear regression results (R(2)) showed that deviation from the normal retinal nerve fiber layer thickness at optical coherence tomography clock hour positions 6 o'clock, 7 o'clock, and 8 o'clock (inferior and inferior temporal) was best correlated with standard automated perimetry pattern deviation in visual field zones corresponding to the superior arcuate and nasal step regions (R(2) range, 0.34-0.57). These associations were much stronger than those between clock hour position 6 o'clock and the visual field zone corresponding to the inferior nasal step region (R(2) = 0.01). Localized retinal nerve fiber layer thinning, measured by optical coherence tomography, is topographically related to decreased localized standard automated perimetry sensitivity in glaucoma patients.
Automating linear accelerator quality assurance.
Eckhause, Tobias; Al-Hallaq, Hania; Ritter, Timothy; DeMarco, John; Farrey, Karl; Pawlicki, Todd; Kim, Gwe-Ya; Popple, Richard; Sharma, Vijeshwar; Perez, Mario; Park, SungYong; Booth, Jeremy T; Thorwarth, Ryan; Moran, Jean M
2015-10-01
The purpose of this study was 2-fold. One purpose was to develop an automated, streamlined quality assurance (QA) program for use by multiple centers. The second purpose was to evaluate machine performance over time for multiple centers using linear accelerator (Linac) log files and electronic portal images. The authors sought to evaluate variations in Linac performance to establish as a reference for other centers. The authors developed analytical software tools for a QA program using both log files and electronic portal imaging device (EPID) measurements. The first tool is a general analysis tool which can read and visually represent data in the log file. This tool, which can be used to automatically analyze patient treatment or QA log files, examines the files for Linac deviations which exceed thresholds. The second set of tools consists of a test suite of QA fields, a standard phantom, and software to collect information from the log files on deviations from the expected values. The test suite was designed to focus on the mechanical tests of the Linac to include jaw, MLC, and collimator positions during static, IMRT, and volumetric modulated arc therapy delivery. A consortium of eight institutions delivered the test suite at monthly or weekly intervals on each Linac using a standard phantom. The behavior of various components was analyzed for eight TrueBeam Linacs. For the EPID and trajectory log file analysis, all observed deviations which exceeded established thresholds for Linac behavior resulted in a beam hold off. In the absence of an interlock-triggering event, the maximum observed log file deviations between the expected and actual component positions (such as MLC leaves) varied from less than 1% to 26% of published tolerance thresholds. The maximum and standard deviations of the variations due to gantry sag, collimator angle, jaw position, and MLC positions are presented. Gantry sag among Linacs was 0.336 ± 0.072 mm. The standard deviation in MLC position, as determined by EPID measurements, across the consortium was 0.33 mm for IMRT fields. With respect to the log files, the deviations between expected and actual positions for parameters were small (<0.12 mm) for all Linacs. Considering both log files and EPID measurements, all parameters were well within published tolerance values. Variations in collimator angle, MLC position, and gantry sag were also evaluated for all Linacs. The performance of the TrueBeam Linac model was shown to be consistent based on automated analysis of trajectory log files and EPID images acquired during delivery of a standardized test suite. The results can be compared directly to tolerance thresholds. In addition, sharing of results from standard tests across institutions can facilitate the identification of QA process and Linac changes. These reference values are presented along with the standard deviation for common tests so that the test suite can be used by other centers to evaluate their Linac performance against those in this consortium.
Rhee, Ye-Kyu; Huh, Yoon-Hyuk; Cho, Lee-Ra; Park, Chan-Jin
2015-12-01
The aim of this study is to evaluate the appropriate impression technique by analyzing the superimposition of 3D digital model for evaluating accuracy of conventional impression technique and digital impression. Twenty-four patients who had no periodontitis or temporomandibular joint disease were selected for analysis. As a reference model, digital impressions with a digital impression system were performed. As a test models, for conventional impression dual-arch and full-arch, impression techniques utilizing addition type polyvinylsiloxane for fabrication of cast were applied. 3D laser scanner is used for scanning the cast. Each 3 pairs for 25 STL datasets were imported into the inspection software. The three-dimensional differences were illustrated in a color-coded map. For three-dimensional quantitative analysis, 4 specified contact locations(buccal and lingual cusps of second premolar and molar) were established. For twodimensional quantitative analysis, the sectioning from buccal cusp to lingual cusp of second premolar and molar were acquired depending on the tooth axis. In color-coded map, the biggest difference between intraoral scanning and dual-arch impression was seen (P<.05). In three-dimensional analysis, the biggest difference was seen between intraoral scanning and dual-arch impression and the smallest difference was seen between dual-arch and full-arch impression. The two- and three-dimensional deviations between intraoral scanner and dual-arch impression was bigger than full-arch and dual-arch impression (P<.05). The second premolar showed significantly bigger three-dimensional deviations than the second molar in the three-dimensional deviations (P>.05).
Rhee, Ye-Kyu
2015-01-01
PURPOSE The aim of this study is to evaluate the appropriate impression technique by analyzing the superimposition of 3D digital model for evaluating accuracy of conventional impression technique and digital impression. MATERIALS AND METHODS Twenty-four patients who had no periodontitis or temporomandibular joint disease were selected for analysis. As a reference model, digital impressions with a digital impression system were performed. As a test models, for conventional impression dual-arch and full-arch, impression techniques utilizing addition type polyvinylsiloxane for fabrication of cast were applied. 3D laser scanner is used for scanning the cast. Each 3 pairs for 25 STL datasets were imported into the inspection software. The three-dimensional differences were illustrated in a color-coded map. For three-dimensional quantitative analysis, 4 specified contact locations(buccal and lingual cusps of second premolar and molar) were established. For twodimensional quantitative analysis, the sectioning from buccal cusp to lingual cusp of second premolar and molar were acquired depending on the tooth axis. RESULTS In color-coded map, the biggest difference between intraoral scanning and dual-arch impression was seen (P<.05). In three-dimensional analysis, the biggest difference was seen between intraoral scanning and dual-arch impression and the smallest difference was seen between dual-arch and full-arch impression. CONCLUSION The two- and three-dimensional deviations between intraoral scanner and dual-arch impression was bigger than full-arch and dual-arch impression (P<.05). The second premolar showed significantly bigger three-dimensional deviations than the second molar in the three-dimensional deviations (P>.05). PMID:26816576
Development of Avionics Installation Interface Standards.
1981-12-01
design and manufacturing process routinely used to minimize the susceptibility of the equipment to corrosion . 4.2.7 Form/Fit Working Group The Form...since it would include both the LRU repack- aging and the required aircraft reconfiguration. The smallest impact is achieved when an avionics or...Smith ARINC Research Corporation X D. Snell Boeing Aerospace Corporation .. Steele Masterite Industries E. Straub ARINC Research Corporation X 1
Giordano, N
2015-10-01
The perceptual results of Plomp and Levelt [J. Acoust. Soc. Am. 38, 548-560 (1965)] for the sensory dissonance of a pair of pure tones are used to estimate the dissonance of pairs of piano tones. By using the spectra of tones measured for a real piano, the effect of the inharmonicity of the tones is included. This leads to a prediction for how the tuning of this piano should deviate from an ideal equal tempered scale so as to give the smallest sensory dissonance and hence give the most pleasing tuning. The results agree with the well known "Railsback stretch," the average tuning curve produced by skilled piano technicians. The authors' analysis thus gives a quantitative explanation of the magnitude of the Railsback stretch in terms of the human perception of dissonance.
NASA Astrophysics Data System (ADS)
Habchi, Chawki; Bohbot, Julien; Schmid, Andreas; Herrmann, Kai
2015-12-01
In this paper, a comprehensive two-fluid model is suggested in order to compute the in-nozzle cavitating flow and the primary atomization of liquid jets, simultaneously. This model has been applied to the computation of a typical large marine Diesel injector. The numerical results have shown a strong correlation between the in-nozzle cavitating flow and the ensuing spray orientation and atomization. Indeed, the results have confirmed the existence of an off-axis liquid core. This asymmetry is likely to be at the origin of the spray deviation observed experimentally. In addition, the primary atomization begins very close to the orifice exit as in the experiments, and the smallest droplets are generated due to cavitation pocket shape oscillations located at the same side, inside the orifice.
Precision timing measurements of PSR J1012+5307
NASA Astrophysics Data System (ADS)
Lange, Ch.; Camilo, F.; Wex, N.; Kramer, M.; Backer, D. C.; Lyne, A. G.; Doroshenko, O.
2001-09-01
We present results and applications of high-precision timing measurements of the binary millisecond pulsar J1012+5307. Combining our radio timing measurements with results based on optical observations, we derive complete 3D velocity information for this system. Correcting for Doppler effects, we derive the intrinsic spin parameters of this pulsar and a characteristic age of 8.6+/-1.9Gyr. Our upper limit for the orbital eccentricity of only 8×10-7 (68 per cent confidence level) is the smallest ever measured for a binary system. We demonstrate that this makes the pulsar an ideal laboratory in which to test certain aspects of alternative theories of gravitation. Our precision measurements suggest deviations from a simple pulsar spin-down timing model, which are consistent with timing noise and the extrapolation of the known behaviour of slowly rotating pulsars.
In vivo dosimetry for external photon treatments of head and neck cancers by diodes and TLDS.
Tung, C J; Wang, H C; Lo, S H; Wu, J M; Wang, C J
2004-01-01
In vivo dosimetry was implemented for treatments of head and neck cancers in the large fields. Diode and thermoluminescence dosemeter (TLD) measurements were carried out for the linear accelerators of 6 MV photon beams. ESTRO in vivo dosimetry protocols were followed in the determination of midline doses from measurements of entrance and exit doses. Of the fields monitored by diodes, the maximum absolute deviation of measured midline doses from planned target doses was 8%, with the mean value and the standard deviation of -1.0 and 2.7%. If planned target doses were calculated using radiological water equivalent thicknesses rather than patient geometric thicknesses, the maximum absolute deviation dropped to 4%, with the mean and the standard deviation of 0.7 and 1.8%. For in vivo dosimetry monitored by TLDs, the shift in mean dose remained small but the statistical precision became poor.
A visual tristimulus projection colorimeter.
Valberg, A
1971-01-01
Based on the optical principle of a slide projector, a visual tristimulus projection colorimeter has been developed. The calorimeter operates with easily interchangeable sets of primary color filters placed in a frame at the objective. The apparatus has proved to be fairly accurate. The reproduction of the color matches as measured by the standard deviation is equal to the visual sensitivity to color differences for each observer. Examples of deviations in the matches among individuals as well as deviations compared with the CIE 1931 Standard Observer are given. These deviations are demonstrated to be solely due to individual differences in the perception of metameric colors. Thus, taking advantage of an objective observation (allowing all adjustments to be judged by a group of impartial observers), the colorimeter provides an excellent aid in the study of discrimination, metamerism, and related effects which are of considerable interest in current research in colorimetry and in the study of color vision tests.
Discriminating crop and other canopies by overlapping binary image layers
NASA Astrophysics Data System (ADS)
Doi, Ryoichi
2013-02-01
For optimal management of agricultural fields by remote sensing, discrimination of the crop canopy from weeds and other objects is essential. In a digital photograph, a rice canopy was discriminated from a variety of weed and tree canopies and other objects by overlapping binary image layers of red-green-blue and other color components indicating the pixels with target canopy-specific (intensity) values based on the ranges of means ±(3×) standard deviations. By overlapping and merging the binary image layers, the target canopy specificity improved to 0.0015 from 0.027 for the yellow 1× standard deviation binary image layer, which was the best among all combinations of color components and means ±(3×) standard deviations. The most target rice canopy-likely pixels were further identified by limiting the pixels at different luminosity values. The discriminatory power was also visually demonstrated in this manner.
Middle school transition and body weight outcomes: Evidence from Arkansas Public Schoolchildren.
Zeng, Di; Thomsen, Michael R; Nayga, Rodolfo M; Rouse, Heather L
2016-05-01
There is evidence that middle school transition adversely affects educational and psychological outcomes of pre-teen children, but little is known about the impacts of middle school transition on other aspects of health. In this article, we estimate the impact of middle school transition on the body mass index (BMI) of public schoolchildren in Arkansas, United States. Using an instrumental variable approach, we find that middle school transition in grade 6 led to a moderate decrease of 0.04 standard deviations in BMI z-scores for all students. Analysis by subsample indicated that this result was driven by boys (0.06-0.07 standard deviations) and especially by non-minority boys (0.09 standard deviations). We speculate that the changing levels of physical activities associated with middle school transition provide the most reasonable explanation for this result. Copyright © 2015 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jafarov, E. E.; Parsekian, A. D.; Schaefer, K.
Ground penetrating radar (GPR) has emerged as an effective tool for estimating active layer thickness (ALT) and volumetric water content (VWC) within the active layer. In August 2013, we conducted a series of GPR and probing surveys using a 500 MHz antenna and metallic probe around Barrow, Alaska. Here, we collected about 15 km of GPR data and 1.5 km of probing data. We describe the GPR data processing workflow from raw GPR data to the estimated ALT and VWC. We then include the corresponding uncertainties for each measured and estimated parameter. The estimated average GPR-derived ALT was 41 cm,more » with a standard deviation of 9 cm. The average probed ALT was 40 cm, with a standard deviation of 12 cm. The average GPR-derived VWC was 0.65, with a standard deviation of 0.14.« less
Migration in the shearing sheet and estimates for young open cluster migration
NASA Astrophysics Data System (ADS)
Quillen, Alice C.; Nolting, Eric; Minchev, Ivan; De Silva, Gayandhi; Chiappini, Cristina
2018-04-01
Using tracer particles embedded in self-gravitating shearing sheet N-body simulations, we investigate the distance in guiding centre radius that stars or star clusters can migrate in a few orbital periods. The standard deviations of guiding centre distributions and maximum migration distances depend on the Toomre or critical wavelength and the contrast in mass surface density caused by spiral structure. Comparison between our simulations and estimated guiding radii for a few young supersolar metallicity open clusters, including NGC 6583, suggests that the contrast in mass surface density in the solar neighbourhood has standard deviation (in the surface density distribution) divided by mean of about 1/4 and larger than measured using COBE data by Drimmel and Spergel. Our estimate is consistent with a standard deviation of ˜0.07 dex in the metallicities measured from high-quality spectroscopic data for 38 young open clusters (<1 Gyr) with mean galactocentric radius 7-9 kpc.
Jafarov, E. E.; Parsekian, A. D.; Schaefer, K.; ...
2018-01-09
Ground penetrating radar (GPR) has emerged as an effective tool for estimating active layer thickness (ALT) and volumetric water content (VWC) within the active layer. In August 2013, we conducted a series of GPR and probing surveys using a 500 MHz antenna and metallic probe around Barrow, Alaska. Here, we collected about 15 km of GPR data and 1.5 km of probing data. We describe the GPR data processing workflow from raw GPR data to the estimated ALT and VWC. We then include the corresponding uncertainties for each measured and estimated parameter. The estimated average GPR-derived ALT was 41 cm,more » with a standard deviation of 9 cm. The average probed ALT was 40 cm, with a standard deviation of 12 cm. The average GPR-derived VWC was 0.65, with a standard deviation of 0.14.« less
The Cost of Uncertain Life Span*
Edwards, Ryan D.
2012-01-01
A considerable amount of uncertainty surrounds the length of human life. The standard deviation in adult life span is about 15 years in the U.S., and theory and evidence suggest it is costly. I calibrate a utility-theoretic model of preferences over length of life and show that one fewer year in standard deviation is worth about half a mean life year. Differences in the standard deviation exacerbate cross-sectional differences in life expectancy between the U.S. and other industrialized countries, between rich and poor countries, and among poor countries. Accounting for the cost of life-span variance also appears to amplify recently discovered patterns of convergence in world average human well-being. This is partly for methodological reasons and partly because unconditional variance in human length of life, primarily the component due to infant mortality, has exhibited even more convergence than life expectancy. PMID:22368324
On the linear relation between the mean and the standard deviation of a response time distribution.
Wagenmakers, Eric-Jan; Brown, Scott
2007-07-01
Although it is generally accepted that the spread of a response time (RT) distribution increases with the mean, the precise nature of this relation remains relatively unexplored. The authors show that in several descriptive RT distributions, the standard deviation increases linearly with the mean. Results from a wide range of tasks from different experimental paradigms support a linear relation between RT mean and RT standard deviation. Both R. Ratcliff's (1978) diffusion model and G. D. Logan's (1988) instance theory of automatization provide explanations for this linear relation. The authors identify and discuss 3 specific boundary conditions for the linear law to hold. The law constrains RT models and supports the use of the coefficient of variation to (a) compare variability while controlling for differences in baseline speed of processing and (b) assess whether changes in performance with practice are due to quantitative speedup or qualitative reorganization. Copyright 2007 APA.
Quantifying relative importance: Computing standardized effects in models with binary outcomes
Grace, James B.; Johnson, Darren; Lefcheck, Jonathan S.; Byrnes, Jarrett E.K.
2018-01-01
Results from simulation studies show that both the LT and OE methods of standardization support a similarly-broad range of coefficient comparisons. The LT method estimates effects that reflect underlying latent-linear propensities, while the OE method computes a linear approximation for the effects of predictors on binary responses. The contrast between assumptions for the two methods is reflected in persistently weaker standardized effects associated with OE standardization. Reliance on standard deviations for standardization (the traditional approach) is critically examined and shown to introduce substantial biases when predictors are non-Gaussian. The use of relevant ranges in place of standard deviations has the capacity to place LT and OE standardized coefficients on a more comparable scale. As ecologists address increasingly complex hypotheses, especially those that involve comparing the influences of different controlling factors (e.g., top-down versus bottom-up or biotic versus abiotic controls), comparable coefficients become a necessary component for evaluations.
NASA Astrophysics Data System (ADS)
Yang, Yong; Li, Chengshan
2017-10-01
The effect of minor loop size on the magnetic stiffness has not been paid attention to by most researchers in experimental and theoretical studies about the high temperature superconductor (HTS) magnetic levitation system. In this work, we numerically investigate the average magnetic stiffness obtained by the minor loop traverses Δz (or Δx) varying from 0.1 mm to 2 mm in zero field cooling and field cooling regimes, respectively. The approximate values of the magnetic stiffness with zero traverse are obtained using the method of linear extrapolation. Compared with the average magnetic stiffness gained by any minor loop traverse, these approximate values are Not always close to the average magnetic stiffness produced by the smallest size of minor loops. The relative deviation ranges of average magnetic stiffness gained by the usually minor loop traverse (1 or 2 mm) are presented by the ratios of approximate values to average stiffness for different moving processes and two typical cooling conditions. The results show that most of average magnetic stiffness are remarkably influenced by the sizes of minor loop, which indicates that the magnetic stiffness obtained by a single minor loop traverse Δ z or Δ x, for example, 1 or 2 mm, can be generally caused a large deviation.
Arnaudo, Maria Eugenia; Bona, Paula; Soibelzon, Leopoldo Hector; Schubert, Blaine W
2016-12-01
Here we present the most detailed morphological study of the auditory region of a tremarctinae bear, Arctotherium tarijense Ameghino. In addition, we provide new anatomical information of the Tremarctinae inner ear, such as coplanarity and deviation from orthogonality of the semicircular canals, as an approach to infer the head movements which encountered the extinct forms in locomotion. Based on morphological comparisons, A. tarijense exhibits the following particular features: the cavum tympani presents the highest relative volume compared with other ursids; the processus paraoccipitalis has a foramen that is absent in other tremarctines; there is only one (ventral) recess in the anterior region of the cavum tympani; and the recessus epytimpanicus is the smallest for all ursids studied. In relation to the inner ear, A. tarijense shows the lowest values of orthogonality deviation and highest scores of locomotor agility. Based on this, is possible to make a preliminary proposal that this species had a relative high vestibular sensibility and therefore a better ability to explore different kind of habitats. However, this hypothesis might be contrasted among bears taking into account the orientation of each semicircular canal in a phylogenetic framework. © 2016 Anatomical Society.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borot de Battisti, M; Maenhout, M; Lagendijk, J J W
Purpose: To develop a new method which adaptively determines the optimal needle insertion sequence for HDR prostate brachytherapy involving divergent needle-by-needle dose delivery by e.g. a robotic device. A needle insertion sequence is calculated at the beginning of the intervention and updated after each needle insertion with feedback on needle positioning errors. Methods: Needle positioning errors and anatomy changes may occur during HDR brachytherapy which can lead to errors in the delivered dose. A novel strategy was developed to calculate and update the needle sequence and the dose plan after each needle insertion with feedback on needle positioning errors. Themore » dose plan optimization was performed by numerical simulations. The proposed needle sequence determination optimizes the final dose distribution based on the dose coverage impact of each needle. This impact is predicted stochastically by needle insertion simulations. HDR procedures were simulated with varying number of needle insertions (4 to 12) using 11 patient MR data-sets with PTV, prostate, urethra, bladder and rectum delineated. Needle positioning errors were modeled by random normally distributed angulation errors (standard deviation of 3 mm at the needle’s tip). The final dose parameters were compared in the situations where the needle with the largest vs. the smallest dose coverage impact was selected at each insertion. Results: Over all scenarios, the percentage of clinically acceptable final dose distribution improved when the needle selected had the largest dose coverage impact (91%) compared to the smallest (88%). The differences were larger for few (4 to 6) needle insertions (maximum difference scenario: 79% vs. 60%). The computation time of the needle sequence optimization was below 60s. Conclusion: A new adaptive needle sequence determination for HDR prostate brachytherapy was developed. Coupled to adaptive planning, the selection of the needle with the largest dose coverage impact increases chances of reaching the clinical constraints. M. Borot de Battisti is funded by Philips Medical Systems Nederland B.V.; M. Moerland is principal investigator on a contract funded by Philips Medical Systems Nederland B.V.; G. Hautvast and D. Binnekamp are fulltime employees of Philips Medical Systems Nederland B.V.« less
Response of jammed packings to thermal fluctuations
NASA Astrophysics Data System (ADS)
Wu, Qikai; Bertrand, Thibault; Shattuck, Mark D.; O'Hern, Corey S.
2017-12-01
We focus on the response of mechanically stable (MS) packings of frictionless, bidisperse disks to thermal fluctuations, with the aim of quantifying how nonlinearities affect system properties at finite temperature. In contrast, numerous prior studies characterized the structural and mechanical properties of MS packings of frictionless spherical particles at zero temperature. Packings of disks with purely repulsive contact interactions possess two main types of nonlinearities, one from the form of the interaction potential (e.g., either linear or Hertzian spring interactions) and one from the breaking (or forming) of interparticle contacts. To identify the temperature regime at which the contact-breaking nonlinearities begin to contribute, we first calculated the minimum temperatures Tc b required to break a single contact in the MS packing for both single- and multiple-eigenmode perturbations of the T =0 MS packing. We find that the temperature required to break a single contact for equal velocity-amplitude perturbations involving all eigenmodes approaches the minimum value obtained for a perturbation in the direction connecting disk pairs with the smallest overlap. We then studied deviations in the constant volume specific heat C¯V and deviations of the average disk positions Δ r from their T =0 values in the temperature regime TC ¯V
NASA Astrophysics Data System (ADS)
Grabsch, Aurélien; Majumdar, Satya N.; Texier, Christophe
2017-06-01
Invariant ensembles of random matrices are characterized by the distribution of their eigenvalues \\{λ _1,\\ldots ,λ _N\\}. We study the distribution of truncated linear statistics of the form \\tilde{L}=\\sum _{i=1}^p f(λ _i) with p
Determining the Equation of State (EoS) Parameters for Ballistic Gelatin
2015-09-01
standard deviation. The specific heat measured at room temperature reported in (Winter 1975) is approximately 1.13 cal/g/°C (= 4.73 J /g/K). Fig. 4...Piatt 2010) Table 3 Specific heat capacity, average heat capacity, and standard deviation Temperature (°C) Cp [ J /(g·K)] Cp Cp Cp Average Cp...density amorphous ice and their implications on pressure induced amorphization. J Chem Physics. 2005;122:124710. Appleby-Thomas GJ, Hazell PJ
Precision Geolocation of Active Electromagnetic Sensors Using Stationary Magnetic Sensors
2009-09-01
0.0003, 0.0003 ] m TiltMeter Mean Pitch: -1.71576990 and Roll: 0.92591697 LSQ Moment Pitch: 0.00576850 and Roll: -0.35543026 Run #5...Standard deviation of optimized solution: [ 0.0028, 0.0014, 0.0012 ] m TiltMeter Mean Pitch: -1.08757549 and Roll: 1.09065730 LSQ Moment...0.00, 0.00, -434.95 ] Standard deviation of optimized solution: [ 0.0051, 0.0031, 0.0035 ] m TiltMeter Mean Pitch: 0.05301905
Coherent and Semiclassical States of a Charged Particle in a Constant Electric Field
NASA Astrophysics Data System (ADS)
Adorno, T. C.; Pereira, A. S.
2018-05-01
The method of integrals of motion is used to construct families of generalized coherent states of a nonrelativistic spinless charged particle in a constant electric field. Families of states, differing in the values of their standard deviations at the initial time, are obtained. Depending on the initial values of the standard deviations, and also on the electric field, it turns out to be possible to identify some families with semiclassical states.
An estimator for the standard deviation of a natural frequency. I.
NASA Technical Reports Server (NTRS)
Schiff, A. J.; Bogdanoff, J. L.
1971-01-01
A brief review of mean-square approximate systems is given. The case in which the masses are deterministic is considered first in the derivation of an estimator for the upper bound of the standard deviation of a natural frequency. Two examples presented include a two-degree-of-freedom system and a case in which the disorder in the springs is perfectly correlated. For purposes of comparison, a Monte Carlo simulation was done on a digital computer.
NASA Astrophysics Data System (ADS)
Huang, Dong; Campos, Edwin; Liu, Yangang
2014-09-01
Statistical characteristics of cloud variability are examined for their dependence on averaging scales and best representation of probability density function with the decade-long retrieval products of cloud liquid water path (LWP) from the tropical western Pacific (TWP), Southern Great Plains (SGP), and North Slope of Alaska (NSA) sites of the Department of Energy's Atmospheric Radiation Measurement Program. The statistical moments of LWP show some seasonal variation at the SGP and NSA sites but not much at the TWP site. It is found that the standard deviation, relative dispersion (the ratio of the standard deviation to the mean), and skewness all quickly increase with the averaging window size when the window size is small and become more or less flat when the window size exceeds 12 h. On average, the cloud LWP at the TWP site has the largest values of standard deviation, relative dispersion, and skewness, whereas the NSA site exhibits the least. Correlation analysis shows that there is a positive correlation between the mean LWP and the standard deviation. The skewness is found to be closely related to the relative dispersion with a correlation coefficient of 0.6. The comparison further shows that the lognormal, Weibull, and gamma distributions reasonably explain the observed relationship between skewness and relative dispersion over a wide range of scales.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Dong; Campos, Edwin; Liu, Yangang
2014-09-17
Statistical characteristics of cloud variability are examined for their dependence on averaging scales and best representation of probability density function with the decade-long retrieval products of cloud liquid water path (LWP) from the tropical western Pacific (TWP), Southern Great Plains (SGP), and North Slope of Alaska (NSA) sites of the Department of Energy’s Atmospheric Radiation Measurement Program. The statistical moments of LWP show some seasonal variation at the SGP and NSA sites but not much at the TWP site. It is found that the standard deviation, relative dispersion (the ratio of the standard deviation to the mean), and skewness allmore » quickly increase with the averaging window size when the window size is small and become more or less flat when the window size exceeds 12 h. On average, the cloud LWP at the TWP site has the largest values of standard deviation, relative dispersion, and skewness, whereas the NSA site exhibits the least. Correlation analysis shows that there is a positive correlation between the mean LWP and the standard deviation. The skewness is found to be closely related to the relative dispersion with a correlation coefficient of 0.6. The comparison further shows that the log normal, Weibull, and gamma distributions reasonably explain the observed relationship between skewness and relative dispersion over a wide range of scales.« less
Oberg, K.A.; Schmidt, A.R.
1994-01-01
A total of 213 measurements of leakage were made at three control structures near Chicago, Ill.--the Chicago River Controlling Works (CRCW), Thomas J. O'Brien Lock and Dam (O'Brien), and Wilmette Pumping Station (Wilmette)--using acoustic Doppler current profilers (ADCP's) and dye-dilution techniques. The CRCW consists of the Chicago Lock and two sets of sluice gates connected by a network of harbor walls. Leakage measurements were made in April, May, July, September, and October 1993 using an ADCP. The mean and standard deviation of leakage measured by the ADCP for the Chicago Lock river gate were 133 and 39 cubic feet per second, respectively. The mean and standard deviation of the leakage measurements at CRCW were 204 and 70 cubic feet per second, respectively. The mean and standard deviation of leakage measurements at O'Brien on September 17, 1993, were 21 and 10 cubic feet per second, respectively. The mean and standard deviation leakage measured at Wilmette using the ADCP were 59 and 8 cubic feet per second, respectively, in April 1993. After the pump bays at Wilmette were sealed in July 1993, the leakage dropped to less than 15 cubic feet per second in September 1993. Discharge estimated by dye-dilution at the Chicago Lock on July 15, 1993, was 160 cubic feet per second, or within 8 percent of the discharge measured with the ADCP. (USGS)
Hazardous Traffic Event Detection Using Markov Blanket and Sequential Minimal Optimization (MB-SMO)
Yan, Lixin; Zhang, Yishi; He, Yi; Gao, Song; Zhu, Dunyao; Ran, Bin; Wu, Qing
2016-01-01
The ability to identify hazardous traffic events is already considered as one of the most effective solutions for reducing the occurrence of crashes. Only certain particular hazardous traffic events have been studied in previous studies, which were mainly based on dedicated video stream data and GPS data. The objective of this study is twofold: (1) the Markov blanket (MB) algorithm is employed to extract the main factors associated with hazardous traffic events; (2) a model is developed to identify hazardous traffic event using driving characteristics, vehicle trajectory, and vehicle position data. Twenty-two licensed drivers were recruited to carry out a natural driving experiment in Wuhan, China, and multi-sensor information data were collected for different types of traffic events. The results indicated that a vehicle’s speed, the standard deviation of speed, the standard deviation of skin conductance, the standard deviation of brake pressure, turn signal, the acceleration of steering, the standard deviation of acceleration, and the acceleration in Z (G) have significant influences on hazardous traffic events. The sequential minimal optimization (SMO) algorithm was adopted to build the identification model, and the accuracy of prediction was higher than 86%. Moreover, compared with other detection algorithms, the MB-SMO algorithm was ranked best in terms of the prediction accuracy. The conclusions can provide reference evidence for the development of dangerous situation warning products and the design of intelligent vehicles. PMID:27420073
Javidi, Bahram; Markman, Adam; Rawat, Siddharth; O'Connor, Timothy; Anand, Arun; Andemariam, Biree
2018-05-14
We present a spatio-temporal analysis of cell membrane fluctuations to distinguish healthy patients from patients with sickle cell disease. A video hologram containing either healthy red blood cells (h-RBCs) or sickle cell disease red blood cells (SCD-RBCs) was recorded using a low-cost, compact, 3D printed shearing interferometer. Reconstructions were created for each hologram frame (time steps), forming a spatio-temporal data cube. Features were extracted by computing the standard deviations and the mean of the height fluctuations over time and for every location on the cell membrane, resulting in two-dimensional standard deviation and mean maps, followed by taking the standard deviations of these maps. The optical flow algorithm was used to estimate the apparent motion fields between subsequent frames (reconstructions). The standard deviation of the magnitude of the optical flow vectors across all frames was then computed. In addition, seven morphological cell (spatial) features based on optical path length were extracted from the cells to further improve the classification accuracy. A random forest classifier was trained to perform cell identification to distinguish between SCD-RBCs and h-RBCs. To the best of our knowledge, this is the first report of machine learning assisted cell identification and diagnosis of sickle cell disease based on cell membrane fluctuations and morphology using both spatio-temporal and spatial analysis.
NASA Astrophysics Data System (ADS)
Lee, Hyun Jeong; Yea, Ji Woon; Oh, Se An
2015-07-01
Respiratory-gated radiation therapy (RGRT) has been used to minimize the dose to normal tissue in lung-cancer radiotherapy. The present research aims to improve the regularity of respiration in RGRT by using a video-coached respiration guiding system. In the study, 16 patients with lung cancer were evaluated. The respiration signals of the patients were measured by using a realtime position management (RPM) respiratory gating system (Varian, USA), and the patients were trained using the video-coaching respiration guiding system. The patients performed free breathing and guided breathing, and the respiratory cycles were acquired for ~5 min. Then, Microsoft Excel 2010 software was used to calculate the mean and the standard deviation for each phase. The standard deviation was computed in order to analyze the improvement in the respiratory regularity with respect to the period and the displacement. The standard deviation of the guided breathing decreased to 48.8% in the inhale peak and 24.2% in the exhale peak compared with the values for the free breathing of patient 6. The standard deviation of the respiratory cycle was found to be decreased when using the respiratory guiding system. The respiratory regularity was significantly improved when using the video-coaching respiration guiding system. Therefore, the system is useful for improving the accuracy and the efficiency of RGRT.
Hazardous Traffic Event Detection Using Markov Blanket and Sequential Minimal Optimization (MB-SMO).
Yan, Lixin; Zhang, Yishi; He, Yi; Gao, Song; Zhu, Dunyao; Ran, Bin; Wu, Qing
2016-07-13
The ability to identify hazardous traffic events is already considered as one of the most effective solutions for reducing the occurrence of crashes. Only certain particular hazardous traffic events have been studied in previous studies, which were mainly based on dedicated video stream data and GPS data. The objective of this study is twofold: (1) the Markov blanket (MB) algorithm is employed to extract the main factors associated with hazardous traffic events; (2) a model is developed to identify hazardous traffic event using driving characteristics, vehicle trajectory, and vehicle position data. Twenty-two licensed drivers were recruited to carry out a natural driving experiment in Wuhan, China, and multi-sensor information data were collected for different types of traffic events. The results indicated that a vehicle's speed, the standard deviation of speed, the standard deviation of skin conductance, the standard deviation of brake pressure, turn signal, the acceleration of steering, the standard deviation of acceleration, and the acceleration in Z (G) have significant influences on hazardous traffic events. The sequential minimal optimization (SMO) algorithm was adopted to build the identification model, and the accuracy of prediction was higher than 86%. Moreover, compared with other detection algorithms, the MB-SMO algorithm was ranked best in terms of the prediction accuracy. The conclusions can provide reference evidence for the development of dangerous situation warning products and the design of intelligent vehicles.
Liang, Xue; Ji, Hai-yan; Wang, Peng-xin; Rao, Zhen-hong; Shen, Bing-hui
2010-01-01
Preprocess method of multiplicative scatter correction (MSC) was used to reject noises in the original spectra produced by the environmental physical factor effectively, then the principal components of near-infrared spectroscopy were calculated by nonlinear iterative partial least squares (NIPALS) before building the back propagation artificial neural networks method (BP-ANN), and the numbers of principal components were calculated by the method of cross validation. The calculated principal components were used as the inputs of the artificial neural networks model, and the artificial neural networks model was used to find the relation between chlorophyll in winter wheat and reflective spectrum, which can predict the content of chlorophyll in winter wheat. The correlation coefficient (r) of calibration set was 0.9604, while the standard deviation (SD) and relative standard deviation (RSD) was 0.187 and 5.18% respectively. The correlation coefficient (r) of predicted set was 0.9600, and the standard deviation (SD) and relative standard deviation (RSD) was 0.145 and 4.21% respectively. It means that the MSC-ANN algorithm can reject noises in the original spectra produced by the environmental physical factor effectively and set up an exact model to predict the contents of chlorophyll in living leaves veraciously to replace the classical method and meet the needs of fast analysis of agricultural products.
Professionalism in medical students at a private medical college in Karachi, Pakistan.
Sobani, Zain-ul-abedeen; Mohyuddin, Muhammad Masaud; Farooq, Fahd; Qaiser, Kanza Noor; Gani, Faiz; Bham, Nida Shahab; Raheem, Ahmed; Mehraj, Vikram; Saeed, Syed Abdul; Sharif, Hasanat; Sheerani, Mughis; Zuberi, Rukhsana Wamiq; Beg, Mohamamd Asim
2013-07-01
To determine levels of professionalism in undergraduate medical students at a private medical college and assess how changes emerge during their training. The study was conducted at Aga Khan University, a tertiary care teaching hospital, during November and December 2011. Freshmen, Year 3 and Year 5 students were requested to fill out a questionnaire. It was designed to assess the participants' levels of professionalism and how they perceived the professional environment around them by incorporating previously described scales. The questionnaire was re-validated on a random sample of practising clinicians at the same hospital. SPSS 17 was used for statistical analysis. The study sample comprised 204 participants. The mean score for level of individual professionalism was 7.72+/-3.43. Only 13 (6.4%) students had a score one standard deviation above the faculty mean. About 24 (11.8%) were one standard deviation and 35 (17.2%) were 2 standard deviations below the faculty mean. The remaining 130 (63.7%) were >2 standard deviations below the faculty mean. Considering the level of education, the mean score for level of professionalism was 8.00+/-3.39 for freshmen, 6.85+/-3.41 for year 3 students, and 8.40+/-3.34 for year 5 students. The currently employed teaching practices inculcating the values of professionalism in medical students are serving as a buffer to maintain the pre-training levels of professionalism from declining.
Pratt, Kenneth W
2015-04-01
This meta-analysis assesses the long-term (up to 70 years) within-laboratory variation of the NIST pH Standard Reference Material® (SRM) tetroxalate, phthalate, phosphate, borate, and carbonate buffers. Values of ΔpH(S), the difference between the certified pH value, pH(S), of each SRM issue and the mean of all pH(S) values for the given SRM at that Celsius temperature, t, are graphed as a function of the SRM issue and t. In most cases, |ΔpH(S)| < 0.004. Deviations from the nominal base:acid amount (mole) ratio of a buffer yield t-independent, constant shifts in ΔpH(S). The mean ΔpH(S) characterizes such deviations. The corresponding mole fraction of impurity in the conjugate buffer component is generally <0.3 %. Changes in the equipment, personnel, materials, and methodology of the pH(S) measurement yield t-dependent variations. The standard deviation of ΔpH(S) characterizes such changes. Standard deviations of ΔpH(S) are generally 0.0015 or less. The results provide a long-term, single-institution complement to the time-specific, multi-institution results of pH key comparisons administered by the Consultative Committee for Metrology in Chemistry and Biology (CCQM).
Identifying Acquisition Patterns of Failure Using Systems Archetypes
2008-04-02
OF PAGES 18 19a. NAME OF RESPONSIBLE PERSON a. REPORT unclassified b . ABSTRACT unclassified c. THIS PAGE unclassified Standard Form 298 (Rev...any but the smallest programs, complete path coverage for defect detection is impractical. Adapted from Pressman , R.S., Software Engineering: A...Firefighting” concept from “Past the Tipping Point” Fix S O B Problem Symptom R “Fixes That Fail” – Systems Archetype S Unintended Consequences S
Mavilio, Alberto; Sisto, Dario; Ferreri, Paolo; Cardascia, Nicola; Alessio, Giovanni
2017-01-01
A significant variability of the second harmonic (2ndH) phase of steady-state pattern electroretinogram (SS-PERG) in intrasession retest has been recently described in glaucoma patients (GP), which has not been found in healthy subjects. To evaluate the reliability of phase variability in retest (a procedure called RE-PERG or REPERG) in the presence of cataract, which is known to affect standard PERG, we tested this procedure in GP, normal controls (NC), and cataract patients (CP). The procedure was performed on 50 GP, 35 NC, and 27 CP. All subjects were examined with RE-PERG and SS-PERG and also with spectral domain optical coherence tomography and standard automated perimetry. Standard deviation of phase and amplitude value of 2ndH were correlated by means of one-way analysis of variance and Pearson correlation, with the mean deviation and pattern standard deviation assessed by standard automated perimetry and retinal nerve fiber layer and the ganglion cell complex thickness assessed by spectral domain optical coherence tomography. Receiver operating characteristics were calculated in cohort populations with and without cataract. Standard deviation of phase of 2ndH was significantly higher in GP with respect to NC ( P <0.001) and CP ( P <0.001), and it correlated with retinal nerve fiber layer ( r =-0.5, P <0.001) and ganglion cell complex ( r =-0.6, P <0.001) defects in GP. Receiver operating characteristic evaluation showed higher specificity of RE-PERG (86.4%; area under the curve 0.93) with respect to SS-PERG (54.5%; area under the curve 0.68) in CP. RE-PERG may improve the specificity of SS-PERG in clinical practice in the discrimination of GP.
X-ray phase contrast imaging at MAMI
NASA Astrophysics Data System (ADS)
El-Ghazaly, M.; Backe, H.; Lauth, W.; Kube, G.; Kunz, P.; Sharafutdinov, A.; Weber, T.
2006-05-01
Experiments have been performed to explore the potential of the low emittance 855MeV electron beam of the Mainz Microtron MAMI for imaging with coherent X-rays. Transition radiation from a micro-focused electron beam traversing a foil stack served as X-ray source with good transverse coherence. Refraction contrast radiographs of low absorbing materials, in particular polymer strings with diameters between 30 and 450μm, were taken with a polychromatic transition radiation X-ray source with a spectral distribution in the energy range between 8 and about 40keV. The electron beam spot size had standard deviation σh = (8.6±0.1)μm in the horizontal and σv = (7.5±0.1)μm in the vertical direction. X-ray films were used as detectors. The source-to-detector distance amounted to 11.4m. The objects were placed in a distance of up to 6m from the X-ray film. Holograms of strings were taken with a beam spot size σv = (0.50±0.05)μm in vertical direction, and a monochromatic X-ray beam of 6keV energy. A good longitudinal coherence has been obtained by the (111) reflection of a flat silicon single crystal in Bragg geometry. It has been demonstrated that a direct exposure CCD chip with a pixel size of 13×13μm^2 provides a highly efficient on-line detector. Contrast images can easily be generated with a complete elimination of all parasitic background. The on-line capability allows a minimization of the beam spot size by observing the smallest visible interference fringe spacings or the number of visible fringes. It has been demonstrated that X-ray films are also very useful detectors. The main advantage in comparison with the direct exposure CCD chip is the resolution. For the Structurix D3 (Agfa) X-ray film the standard deviation of the resolution was measured to be σf = (1.2±0.4)μm, which is about a factor of 6 better than for the direct exposure CCD chip. With the small effective X-ray spot size in vertical direction of σv = (1.2±0.3)μm and a geometrical magnification of up to 7.4 high-quality holograms of tiny transparent strings were taken in which the holographic information is contained in up to 18 interference fringes.
Sarikouch, Samir; Boethig, Dietmar; Peters, Brigitte; Kropf, Siegfried; Dubowy, Karl-Otto; Lange, Peter; Kuehne, Titus; Haverich, Axel; Beerbaum, Philipp
2013-11-01
In repaired congenital heart disease, there is increasing evidence of sex differences in cardiac remodeling, but there is a lack of comparable data for specific congenital heart defects such as in repaired tetralogy of Fallot. In a prospective multicenter study, a cohort of 272 contemporary patients (158 men; mean age, 14.3±3.3 years [range, 8-20 years]) with repaired tetralogy of Fallot underwent cardiac magnetic resonance for ventricular function and metabolic exercise testing. All data were transformed to standard deviation scores according to the Lambda-Mu-Sigma method by relating individual values to their respective 50th percentile (standard deviation score, 0) in sex-specific healthy control subjects. No sex differences were observed in age at repair, type of repair conducted, or overall hemodynamic results. Relative to sex-specific controls, repaired tetralogy of Fallot in women had larger right ventricular end-systolic volumes (standard deviation scores: women, 4.35; men, 3.25; P=0.001), lower right ventricular ejection fraction (women, -2.83; men, -2.12; P=0.011), lower right ventricular muscle mass (women, 1.58; men 2.45; P=0.001), poorer peak oxygen uptake (women, -1.65; men, -1.14; P<0.001), higher VE/VCO2 (ventilation per unit of carbon dioxide production) slopes (women, 0.88; men 0.58; P=0.012), and reduced peak heart rate (women, -2.16; men -1.74; P=0.017). Left ventricular parameters did not differ between sexes. Relative to their respective sex-specific healthy control subjects, derived standard deviation scores in repaired tetralogy of Fallot suggest that women perform poorer than men in terms of right ventricular systolic function as tested by cardiac magnetic resonance and exercise capacity. This effect cannot be explained by selection bias. Further outcome data are required from longitudinal cohort studies.
Mehta, Amar J.; Kloog, Itai; Zanobetti, Antonella; Coull, Brent A.; Sparrow, David; Vokonas, Pantel; Schwartz, Joel
2014-01-01
Background The underlying mechanisms of the association between ambient temperature and cardiovascular morbidity and mortality are not well understood, particularly for daily temperature variability. We evaluated if daily mean temperature and standard deviation of temperature was associated with heart rate-corrected QT interval (QTc) duration, a marker of ventricular repolarization in a prospective cohort of older men. Methods This longitudinal analysis included 487 older men participating in the VA Normative Aging Study with up to three visits between 2000–2008 (n = 743). We analyzed associations between QTc and moving averages (1–7, 14, 21, and 28 days) of the 24-hour mean and standard deviation of temperature as measured from a local weather monitor, and the 24-hour mean temperature estimated from a spatiotemporal prediction model, in time-varying linear mixed-effect regression. Effect modification by season, diabetes, coronary heart disease, obesity, and age was also evaluated. Results Higher mean temperature as measured from the local monitor, and estimated from the prediction model, was associated with longer QTc at moving averages of 21 and 28 days. Increased 24-hr standard deviation of temperature was associated with longer QTc at moving averages from 4 and up to 28 days; a 1.9°C interquartile range increase in 4-day moving average standard deviation of temperature was associated with a 2.8 msec (95%CI: 0.4, 5.2) longer QTc. Associations between 24-hr standard deviation of temperature and QTc were stronger in colder months, and in participants with diabetes and coronary heart disease. Conclusion/Significance In this sample of older men, elevated mean temperature was associated with longer QTc, and increased variability of temperature was associated with longer QTc, particularly during colder months and among individuals with diabetes and coronary heart disease. These findings may offer insight of an important underlying mechanism of temperature-related cardiovascular morbidity and mortality in an older population. PMID:25238150
NASA Technical Reports Server (NTRS)
Warner, Joseph D.; Theofylaktos, Onoufrios
2012-01-01
A method of determining the bit error rate (BER) of a digital circuit from the measurement of the analog S-parameters of the circuit has been developed. The method is based on the measurement of the noise and the standard deviation of the noise in the S-parameters. Once the standard deviation and the mean of the S-parameters are known, the BER of the circuit can be calculated using the normal Gaussian function.
NASA Astrophysics Data System (ADS)
Anees, Amir; Khan, Waqar Ahmad; Gondal, Muhammad Asif; Hussain, Iqtadar
2013-07-01
The aim of this work is to make use of the mean of absolute deviation (MAD) method for the evaluation process of substitution boxes used in the advanced encryption standard. In this paper, we use the MAD technique to analyze some popular and prevailing substitution boxes used in encryption processes. In particular, MAD is applied to advanced encryption standard (AES), affine power affine (APA), Gray, Lui J., Residue Prime, S8 AES, SKIPJACK, and Xyi substitution boxes.
22st Annual National Test and Evaluation Conference
2006-03-09
B1 B2 y ii) Factor B affects the standard deviation C2 C1 y iii) Factor C affects the average and the standard deviation D1 = D2 y iv) Factor D has...22303 UNITED STATES (P) (703)862-0908 (F) (703)970-5700 poole_grady@emc.com Mr. Josh Pressnell RTI 8306 Rugby Rd. Manassas, VA 20111...Ricciardi RTI 8306 Rugby Rd. Manassas, VA 20111-1912 UNITED STATES (P) (703)365-9662 (F) (703)365-9818 michael.ricciardi@rti-world.com Mr
NASA Technical Reports Server (NTRS)
Anspaugh, B. E.; Miyahira, T. F.; Weiss, R. S.
1979-01-01
Computed statistical averages and standard deviations with respect to the measured cells for each intensity temperature measurement condition are presented. Display averages and standard deviations of the cell characteristics in a two dimensional array format are shown: one dimension representing incoming light intensity, and another, the cell temperature. Programs for calculating the temperature coefficients of the pertinent cell electrical parameters are presented, and postirradiation data are summarized.
Evaluation of Acoustic Doppler Current Profiler measurements of river discharge
Morlock, S.E.
1996-01-01
The standard deviations of the ADCP measurements ranged from approximately 1 to 6 percent and were generally higher than the measurement errors predicted by error-propagation analysis of ADCP instrument performance. These error-prediction methods assume that the largest component of ADCP discharge measurement error is instrument related. The larger standard deviations indicate that substantial portions of measurement error may be attributable to sources unrelated to ADCP electronics or signal processing and are functions of the field environment.
Artes, Paul H; Hutchison, Donna M; Nicolela, Marcelo T; LeBlanc, Raymond P; Chauhan, Balwantray C
2005-07-01
To compare test results from second-generation Frequency-Doubling Technology perimetry (FDT2, Humphrey Matrix; Carl-Zeiss Meditec, Dublin, CA) and standard automated perimetry (SAP) in patients with glaucoma. Specifically, to examine the relationship between visual field sensitivity and test-retest variability and to compare total and pattern deviation probability maps between both techniques. Fifteen patients with glaucoma who had early to moderately advanced visual field loss with SAP (mean MD, -4.0 dB; range, +0.2 to -16.1) were enrolled in the study. Patients attended three sessions. During each session, one eye was examined twice with FDT2 (24-2 threshold test) and twice with SAP (Swedish Interactive Threshold Algorithm [SITA] Standard 24-2 test), in random order. We compared threshold values between FDT2 and SAP at test locations with similar visual field coordinates. Test-retest variability, established in terms of test-retest intervals and standard deviations (SDs), was investigated as a function of visual field sensitivity (estimated by baseline threshold and mean threshold, respectively). The magnitude of visual field defects apparent in total and pattern deviation probability maps were compared between both techniques by ordinal scoring. The global visual field indices mean deviation (MD) and pattern standard deviation (PSD) of FDT2 and SAP correlated highly (r > 0.8; P < 0.001). At test locations with high sensitivity (>25 dB with SAP), threshold estimates from FDT2 and SAP exhibited a close, linear relationship, with a slope of approximately 2.0. However, at test locations with lower sensitivity, the relationship was much weaker and ceased to be linear. In comparison with FDT2, SAP showed a slightly larger proportion of test locations with absolute defects (3.0% vs. 2.2% with SAP and FDT2, respectively, P < 0.001). Whereas SAP showed a significant increase in test-retest variability at test locations with lower sensitivity (P < 0.001), there was no relationship between variability and sensitivity with FDT2 (P = 0.46). In comparison with SAP, FDT2 exhibited narrower test-retest intervals at test locations with lower sensitivity (SAP thresholds <25 dB). A comparison of the total and pattern deviation maps between both techniques showed that the total deviation analyses of FDT2 may slightly underestimate the visual field loss apparent with SAP. However, the pattern-deviation maps of both instruments agreed well with each other. The test-retest variability of FDT2 is uniform over the measurement range of the instrument. These properties may provide advantages for the monitoring of patients with glaucoma that should be investigated in longitudinal studies.
What to use to express the variability of data: Standard deviation or standard error of mean?
Barde, Mohini P; Barde, Prajakt J
2012-07-01
Statistics plays a vital role in biomedical research. It helps present data precisely and draws the meaningful conclusions. While presenting data, one should be aware of using adequate statistical measures. In biomedical journals, Standard Error of Mean (SEM) and Standard Deviation (SD) are used interchangeably to express the variability; though they measure different parameters. SEM quantifies uncertainty in estimate of the mean whereas SD indicates dispersion of the data from mean. As readers are generally interested in knowing the variability within sample, descriptive data should be precisely summarized with SD. Use of SEM should be limited to compute CI which measures the precision of population estimate. Journals can avoid such errors by requiring authors to adhere to their guidelines.
Long-term comparisons between two-way satellite and geodetic time transfer systems.
Plumb, John F; Larson, Kristine M
2005-11-01
Global Positioning System (GPS) observations recorded in the United States and Europe were used to evaluate time transfer capabilities of GETT (geodetic time transfer). Timing estimates were compared with two-way satellite time and frequency transfer (TWSTFT) systems. A comparison of calibrated links at the U.S. Naval Observatory, Washington, D.C., and Colorado Springs, CO, yielded agreement of 2.17 ns over 6 months with a standard deviation of 0.73 ns. An uncalibrated link between the National Institute of Standards and Technology (NIST) and Physikalisch-Technische Bundesanstalt, Braunschweig, Germany, has a standard deviation of 0.79 ns over the same time period.
QED is not endangered by the proton's size
NASA Astrophysics Data System (ADS)
De Rújula, A.
2010-10-01
Pohl et al. have reported a very precise measurement of the Lamb-shift in muonic hydrogen (Pohl et al., 2010) [1], from which they infer the radius characterizing the proton's charge distribution. The result is 5 standard deviations away from the one of the CODATA compilation of physical constants. This has been interpreted (Pohl et al., 2010) [1] as possibly requiring a 4.9 standard-deviation modification of the Rydberg constant, to a new value that would be precise to 3.3 parts in 1013, as well as putative evidence for physics beyond the standard model (Flowers, 2010) [2]. I demonstrate that these options are unsubstantiated.
Test-retest reliability of 3D ultrasound measurements of the thoracic spine.
Fölsch, Christian; Schlögel, Stefanie; Lakemeier, Stefan; Wolf, Udo; Timmesfeld, Nina; Skwara, Adrian
2012-05-01
To explore the reliability of the Zebris CMS 20 ultrasound analysis system with pointer application for measuring end-range flexion, end-range extension, and neutral kyphosis angle of the thoracic spine. The study was performed within the School of Physiotherapy in cooperation with the Orthopedic Department at a University Hospital. The thoracic spines of 28 healthy subjects were measured. Measurements for neutral kyphosis angle, end-range flexion, and end-range extension were taken once at each time point. The bone landmarks were palpated by one examiner and marked with a pointer containing 2 transmitters using a frequency of 40 kHz. A third transmitter was fixed to the pelvis, and 3 microphones were used as receiver. The real angle was calculated by the software. Bland-Altman plots with 95% limits of agreement, intraclass correlations (ICC), standard deviations of mean measurements, and standard error of measurements were used for statistical analyses. The test-retest reliability in this study was measured within a 24-hour interval. Statistical parameters were used to judge reliability. The mean kyphosis angle was 44.8° with a standard deviation of 17.3° at the first measurement and a mean of 45.8° with a standard deviation of 16.2° the following day. The ICC was high at 0.95 for the neutral kyphosis angle, and the Bland-Altman 95% limits of agreement were within clinical acceptable margins. The ICC was 0.71 for end-range flexion and 0.34 for end-range extension, whereas the Bland-Altman 95% limits of agreement were wider than with the static measurement of kyphosis. Compared with static measurements, the analysis of motion with 3-dimensional ultrasound showed an increased standard deviation for test-retest measurements. The test-retest reliability of ultrasound measuring of the neutral kyphosis angle of the thoracic spine was demonstrated within 24 hours. Bland-Altman 95% limits of agreement and the standard deviation of differences did not appear to be clinically acceptable for measuring flexion and extension. Copyright © 2012 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Dispersion y dinamica poblacional
USDA-ARS?s Scientific Manuscript database
Dispersal behavior of fruit flies is appetitive. Measures of dispersion involve two different parameter: the maximum distance and the standard distance. Standard distance is a parameter that describes the probalility of dispersion and is mathematically equivalent to the standard deviation around ...
Evaluating Silent Reading Performance with an Eye Tracking System in Patients with Glaucoma
Murata, Noriaki; Fukuchi, Takeo
2017-01-01
Objective To investigate the relationship between silent reading performance and visual field defects in patients with glaucoma using an eye tracking system. Methods Fifty glaucoma patients (Group G; mean age, 52.2 years, standard deviation: 11.4 years) and 20 normal controls (Group N; mean age, 46.9 years; standard deviation: 17.2 years) were included in the study. All participants in Group G had early to advanced glaucomatous visual field defects but better than 20/20 visual acuity in both eyes. Participants silently read Japanese articles written horizontally while the eye tracking system monitored and calculated reading duration per 100 characters, number of fixations per 100 characters, and mean fixation duration, which were compared with mean deviation and visual field index values from Humphrey visual field testing (24–2 and 10–2 Swedish interactive threshold algorithm standard) of the right versus left eye and the better versus worse eye. Results There was a statistically significant difference between Groups G and N in mean fixation duration (G, 233.4 msec; N, 215.7 msec; P = 0.010). Within Group G, significant correlations were observed between reading duration and 24–2 right mean deviation (rs = -0.280, P = 0.049), 24–2 right visual field index (rs = -0.306, P = 0.030), 24–2 worse visual field index (rs = -0.304, P = 0.032), and 10–2 worse mean deviation (rs = -0.326, P = 0.025). Significant correlations were observed between mean fixation duration and 10–2 left mean deviation (rs = -0.294, P = 0.045) and 10–2 worse mean deviation (rs = -0.306, P = 0.037), respectively. Conclusions The severity of visual field defects may influence some aspects of reading performance. At least concerning silent reading, the visual field of the worse eye is an essential element of smoothness of reading. PMID:28095478
Concina, Bruno; Baguenard, Bruno; Calvo, Florent; Bordas, Christian
2010-03-14
The delayed electron emission from small mass-selected anionic tungsten clusters W(n)(-) has been studied for sizes in the range 9 < or = n < or = 21. Kinetic energy spectra have been measured for delays of about 100 ns after laser excitation by a velocity-map imaging spectrometer. They are analyzed in the framework of microreversible statistical theories. The low-energy behavior shows some significant deviations with respect to the classical Langevin capture model, which we interpret as possibly due to the influence of quantum dynamical effects such as tunneling through the centrifugal barrier, rather than shape effects. The cluster temperature has been extracted from both the experimental kinetic energy spectrum and the absolute decay rate. Discrepancies between the two approaches suggest that the sticking probability can be as low as a few percent for the smallest clusters.
A unifying theory for top-heavy ecosystem structure in the ocean.
Woodson, C Brock; Schramski, John R; Joye, Samantha B
2018-01-02
Size generally dictates metabolic requirements, trophic level, and consequently, ecosystem structure, where inefficient energy transfer leads to bottom-heavy ecosystem structure and biomass decreases as individual size (or trophic level) increases. However, many animals deviate from simple size-based predictions by either adopting generalist predatory behavior, or feeding lower in the trophic web than predicted from their size. Here we show that generalist predatory behavior and lower trophic feeding at large body size increase overall biomass and shift ecosystems from a bottom-heavy pyramid to a top-heavy hourglass shape, with the most biomass accounted for by the largest animals. These effects could be especially dramatic in the ocean, where primary producers are the smallest components of the ecosystem. This approach makes it possible to explore and predict, in the past and in the future, the structure of ocean ecosystems without biomass extraction and other impacts.
Localization Counteracts Decoherence in Noisy Floquet Topological Chains
NASA Astrophysics Data System (ADS)
Rieder, M.-T.; Sieberer, L. M.; Fischer, M. H.; Fulga, I. C.
2018-05-01
The topological phases of periodically driven, or Floquet systems, rely on a perfectly periodic modulation of system parameters in time. Even the smallest deviation from periodicity leads to decoherence, causing the boundary (end) states to leak into the system's bulk. Here, we show that in one dimension this decay of topologically protected end states depends fundamentally on the nature of the bulk states: a dispersive bulk results in an exponential decay, while a localized bulk slows the decay down to a diffusive process. The localization can be due to disorder, which remarkably counteracts decoherence even when it breaks the symmetry responsible for the topological protection. We derive this result analytically, using a novel, discrete-time Floquet-Lindblad formalism and confirm our findings with the help of numerical simulations. Our results are particularly relevant for experiments, where disorder can be tailored to protect Floquet topological phases from decoherence.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chong, Irene; Hawkins, Maria; Hansen, Vibeke
2011-11-15
Purpose: There has been no previously published data related to the quantification of rectal motion using cone-beam computed tomography (CBCT) during standard conformal long-course chemoradiotherapy. The purpose of the present study was to quantify the interfractional changes in rectal movement and dimensions and rectal and bladder volume using CBCT and to quantify the bony anatomy displacements to calculate the margins required to account for systematic ({Sigma}) and random ({sigma}) setup errors. Methods and Materials: CBCT images were acquired from 16 patients on the first 3 days of treatment and weekly thereafter. The rectum and bladder were outlined on all CBCTmore » images. The interfraction movement was measured using fixed bony landmarks as references to define the rectal location (upper, mid, and low), The maximal rectal diameter at the three rectal locations was also measured. The bony anatomy displacements were quantified, allowing the calculation of systematic ({Sigma}) and random ({sigma}) setup errors. Results: A total of 123 CBCT data sets were analyzed. Analysis of variance for standard deviation from planning scans showed that rectal anterior and lateral wall movement differed significantly by rectal location. Anterior and lateral rectal wall movements were larger in the mid and upper rectum compared with the low rectum. The posterior rectal wall movement did not change significantly with the rectal location. The rectal diameter changed more in the mid and upper than in the low rectum. No consistent relationship was found between the rectal and bladder volume and time, nor was a significant relationship found between the rectal volume and bladder volume. Conclusions: In the present study, the anterior and lateral rectal movement and rectal diameter were found to change most in the upper rectum, followed by the mid rectum, with the smallest changes seen in the low rectum. Asymmetric margins are warranted to ensure phase 2 coverage.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shibata, K.; Ogata, T.; Nyilas, A.
2006-03-31
Ogata et al. reported in 1996 results of international Round Robin tests on mechanical property measurement of several metals at cryogenic temperatures. Following the report, the standard deviation of Young's modulus of 316L steel is much larger than those of yield and tensile strengths, that is, 4.6 % of the mean value for Young's modulus, while 1.4 % and 1.6 % of the mean values for yield and for tensile strengths, respectively. Therefore, an international Round Robin test on Young's modulus of two austenitic stainless steels at cryogenic temperatures under the participation often institutes from four nations has been initiatedmore » within these two years. As a result, the ratios of standard deviation to the mean values are 4.2 % for 304L and 3.6 % for 316L. Such a drop in the standard deviation is attributable to the decrease in the number of institute owing to the application of single extensometer or direct strain gage technique.« less
Liu, Gordon G; Xue, Xindong; Yu, Chenxi; Wang, Yafeng
2016-09-01
This paper uses longitudinal data from China to examine the causal relationship between structural social capital and health among Chinese older adults. We employ various econometric strategies to control for the potential endogeneity of social capital and account for the possible contextual confounding effects by including community-level social capital. We use three indicators to measure individuals' general, physical, and mental health. Results indicate that social capital has a significant and positive effect on general and physical health. Based on our primary IV findings, a one standard-deviation increase in social capital leads to a 4.9 standard-deviation decrease in the probability of having bad health and a 2.2 standard-deviation decrease in physical activity limitations. Our results are robust to a series of sensitivity checks. Further analysis suggests heterogeneous effects by age but not by gender or area of residence. Copyright © 2016 Elsevier B.V. All rights reserved.
Koenig, Bruce E; Lacey, Douglas S
2014-07-01
In this research project, nine small digital audio recorders were tested using five sets of 30-min recordings at all available recording modes, with consistent audio material, identical source and microphone locations, and identical acoustic environments. The averaged direct current (DC) offset values and standard deviations were measured for 30-sec and 1-, 2-, 3-, 6-, 10-, 15-, and 30-min segments. The research found an inverse association between segment lengths and the standard deviation values and that lengths beyond 30 min may not meaningfully reduce the standard deviation values. This research supports previous studies indicating that measured averaged DC offsets should only be used for exclusionary purposes in authenticity analyses and exhibit consistent values when the general acoustic environment and microphone/recorder configurations were held constant. Measured average DC offset values from exemplar recorders may not be directly comparable to those of submitted digital audio recordings without exactly duplicating the acoustic environment and microphone/recorder configurations. © 2014 American Academy of Forensic Sciences.
Historical Precision of an Ozone Correction Procedure for AM0 Solar Cell Calibration
NASA Technical Reports Server (NTRS)
Snyder, David B.; Jenkins, Phillip; Scheiman, David
2005-01-01
In an effort to improve the accuracy of the high altitude aircraft method for calibration of high band-gap solar cells, the ozone correction procedure has been revisited. The new procedure adjusts the measured short circuit current, Isc, according to satellite based ozone measurements and a model of the atmospheric ozone profile then extrapolates the measurements to air mass zero, AMO. The purpose of this paper is to assess the precision of the revised procedure by applying it to historical data sets. The average Isc of a silicon cell for a flying season increased 0.5% and the standard deviation improved from 0.5% to 0.3%. The 12 year average Isc of a GaAs cell increased 1% and the standard deviation improved from 0.8% to 0.5%. The slight increase in measured Isc and improvement in standard deviation suggests that the accuracy of the aircraft method may improve from 1% to nearly 0.5%.
Active laser ranging with frequency transfer using frequency comb
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Hongyuan; Wei, Haoyun; Yang, Honglei
2016-05-02
A comb-based active laser ranging scheme is proposed for enhanced distance resolution and a common time standard for the entire system. Three frequency combs with different repetition rates are used as light sources at the two ends where the distance is measured. Pulse positions are determined through asynchronous optical sampling and type II second harmonic generation. Results show that the system achieves a maximum residual of 379.6 nm and a standard deviation of 92.9 nm with 2000 averages over 23.6 m. Moreover, as for the frequency transfer, an atom clock and an adjustable signal generator, synchronized to the atom clock, are used asmore » time standards for the two ends to appraise the frequency deviation introduced by the proposed system. The system achieves a residual fractional deviation of 1.3 × 10{sup −16} for 1 s, allowing precise frequency transfer between the two clocks at the two ends.« less
Signal averaging limitations in heterodyne- and direct-detection laser remote sensing measurements
NASA Technical Reports Server (NTRS)
Menyuk, N.; Killinger, D. K.; Menyuk, C. R.
1983-01-01
The improvement in measurement uncertainty brought about by the averaging of increasing numbers of pulse return signals in both heterodyne- and direct-detection lidar systems is investigated. A theoretical analysis is presented which shows the standard deviation of the mean measurement to decrease as the inverse square root of the number of measurements, except in the presence of temporal correlation. Experimental measurements based on a dual-hybrid-TEA CO2 laser differential absorption lidar system are reported which demonstrate that the actual reduction in the standard deviation of the mean in both heterodyne- and direct-detection systems is much slower than the inverse square-root dependence predicted for uncorrelated signals, but is in agreement with predictions in the event of temporal correlation. Results thus favor the use of direct detection at relatively short range where the lower limit of the standard deviation of the mean is about 2 percent, but advantages of heterodyne detection at longer ranges are noted.
Age-independent anti-Müllerian hormone (AMH) standard deviation scores to estimate ovarian function.
Helden, Josef van; Weiskirchen, Ralf
2017-06-01
To determine single year age-specific anti-Müllerian hormone (AMH) standard deviation scores (SDS) for women associated to normal ovarian function and different ovarian disorders resulting in sub- or infertility. Determination of particular year median and mean AMH values with standard deviations (SD), calculation of age-independent cut off SDS for the discrimination between normal ovarian function and ovarian disorders. Single-year-specific median, mean, and SD values have been evaluated for the Beckman Access AMH immunoassay. While the decrease of both median and mean AMH values is strongly correlated with increasing age, calculated SDS values have been shown to be age independent with the differentiation between normal ovarian function measured as occurred ovulation with sufficient luteal activity compared with hyperandrogenemic cycle disorders or anovulation associated with high AMH values and reduced ovarian activity or insufficiency associated with low AMH, respectively. These results will be helpful for the treatment of patients and the ventilation of the different reproductive options. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Smith, Wayne Farrior
1973-01-01
The effect of finite source size on the power statistics in a reverberant room for pure tone excitation was investigated. Theoretical results indicate that the standard deviation of low frequency, pure tone finite sources is always less than that predicted by point source theory and considerably less when the source dimension approaches one-half an acoustic wavelength or greater. A supporting experimental study was conducted utilizing an eight inch loudspeaker and a 30 inch loudspeaker at eleven source positions. The resulting standard deviation of sound power output of the smaller speaker is in excellent agreement with both the derived finite source theory and existing point source theory, if the theoretical data is adjusted to account for experimental incomplete spatial averaging. However, the standard deviation of sound power output of the larger speaker is measurably lower than point source theory indicates, but is in good agreement with the finite source theory.
NASA Technical Reports Server (NTRS)
Chadwick, C.
1984-01-01
This paper describes the development and use of an algorithm to compute approximate statistics of the magnitude of a single random trajectory correction maneuver (TCM) Delta v vector. The TCM Delta v vector is modeled as a three component Cartesian vector each of whose components is a random variable having a normal (Gaussian) distribution with zero mean and possibly unequal standard deviations. The algorithm uses these standard deviations as input to produce approximations to (1) the mean and standard deviation of the magnitude of Delta v, (2) points of the probability density function of the magnitude of Delta v, and (3) points of the cumulative and inverse cumulative distribution functions of Delta v. The approximates are based on Monte Carlo techniques developed in a previous paper by the author and extended here. The algorithm described is expected to be useful in both pre-flight planning and in-flight analysis of maneuver propellant requirements for space missions.
A Priori Subgrid Scale Modeling for a Droplet Laden Temporal Mixing Layer
NASA Technical Reports Server (NTRS)
Okongo, Nora; Bellan, Josette
2000-01-01
Subgrid analysis of a transitional temporal mixing layer with evaporating droplets has been performed using a direct numerical simulation (DNS) database. The DNS is for a Reynolds number (based on initial vorticity thickness) of 600, with droplet mass loading of 0.2. The gas phase is computed using a Eulerian formulation, with Lagrangian droplet tracking. Since Large Eddy Simulation (LES) of this flow requires the computation of unfiltered gas-phase variables at droplet locations from filtered gas-phase variables at the grid points, it is proposed to model these by assuming the gas-phase variables to be given by the filtered variables plus a correction based on the filtered standard deviation, which can be computed from the sub-grid scale (SGS) standard deviation. This model predicts unfiltered variables at droplet locations better than simply interpolating the filtered variables. Three methods are investigated for modeling the SGS standard deviation: Smagorinsky, gradient and scale-similarity. When properly calibrated, the gradient and scale-similarity methods give results in excellent agreement with the DNS.
Brown, Gary S.; Betty, Rita G.; Brockmann, John E.; Lucero, Daniel A.; Souza, Caroline A.; Walsh, Kathryn S.; Boucher, Raymond M.; Tezak, Mathew; Wilson, Mollye C.; Rudolph, Todd
2007-01-01
Polyester-rayon blend wipes were evaluated for efficiency of extraction and recovery of powdered Bacillus atrophaeus spores from stainless steel and painted wallboard surfaces. Method limits of detection were also estimated for both surfaces. The observed mean efficiency of polyester-rayon blend wipe recovery from stainless steel was 0.35 with a standard deviation of ±0.12, and for painted wallboard it was 0.29 with a standard deviation of ±0.15. Evaluation of a sonication extraction method for the polyester-rayon blend wipes produced a mean extraction efficiency of 0.93 with a standard deviation of ±0.09. Wipe recovery quantitative limits of detection were estimated at 90 CFU per unit of stainless steel sample area and 105 CFU per unit of painted wallboard sample area. The method recovery efficiency and limits of detection established in this work provide useful guidance for the planning of incident response environmental sampling following the release of a biological agent such as Bacillus anthracis. PMID:17122390
Brown, Gary S; Betty, Rita G; Brockmann, John E; Lucero, Daniel A; Souza, Caroline A; Walsh, Kathryn S; Boucher, Raymond M; Tezak, Mathew; Wilson, Mollye C; Rudolph, Todd
2007-02-01
Polyester-rayon blend wipes were evaluated for efficiency of extraction and recovery of powdered Bacillus atrophaeus spores from stainless steel and painted wallboard surfaces. Method limits of detection were also estimated for both surfaces. The observed mean efficiency of polyester-rayon blend wipe recovery from stainless steel was 0.35 with a standard deviation of +/-0.12, and for painted wallboard it was 0.29 with a standard deviation of +/-0.15. Evaluation of a sonication extraction method for the polyester-rayon blend wipes produced a mean extraction efficiency of 0.93 with a standard deviation of +/-0.09. Wipe recovery quantitative limits of detection were estimated at 90 CFU per unit of stainless steel sample area and 105 CFU per unit of painted wallboard sample area. The method recovery efficiency and limits of detection established in this work provide useful guidance for the planning of incident response environmental sampling following the release of a biological agent such as Bacillus anthracis.
McLain, B.J.
1993-01-01
Graphite furnace atomic absorption spectrophotometry is a sensitive, precise, and accurate method for the determination of chromium in natural water samples. The detection limit for this analytical method is 0.4 microg/L with a working linear limit of 25.0 microg/L. The precision at the detection limit ranges from 20 to 57 percent relative standard deviation (RSD) with an improvement to 4.6 percent RSD for concentrations more than 3 microg/L. Accuracy of this method was determined for a variety of reference standards that was representative of the analytical range. The results were within the established standard deviations. Samples were spiked with known concentrations of chromium with recoveries ranging from 84 to 122 percent. In addition, a comparison of data between graphite furnace atomic absorption spectrophotometry and direct-current plasma atomic emission spectrometry resulted in suitable agreement between the two methods, with an average deviation of +/- 2.0 microg/L throughout the analytical range.
Exploring local regularities for 3D object recognition
NASA Astrophysics Data System (ADS)
Tian, Huaiwen; Qin, Shengfeng
2016-11-01
In order to find better simplicity measurements for 3D object recognition, a new set of local regularities is developed and tested in a stepwise 3D reconstruction method, including localized minimizing standard deviation of angles(L-MSDA), localized minimizing standard deviation of segment magnitudes(L-MSDSM), localized minimum standard deviation of areas of child faces (L-MSDAF), localized minimum sum of segment magnitudes of common edges (L-MSSM), and localized minimum sum of areas of child face (L-MSAF). Based on their effectiveness measurements in terms of form and size distortions, it is found that when two local regularities: L-MSDA and L-MSDSM are combined together, they can produce better performance. In addition, the best weightings for them to work together are identified as 10% for L-MSDSM and 90% for L-MSDA. The test results show that the combined usage of L-MSDA and L-MSDSM with identified weightings has a potential to be applied in other optimization based 3D recognition methods to improve their efficacy and robustness.
Effect on tricaine methanesulfonate (MS-222) on hematocrit values in rainbow trout (Salmo gairdneri)
Reinitz, G.L.; Rix, J.
1977-01-01
1. Anesthesia of rainbow trout (Salmo gairdneri) with 70 ppm tricaine methanesulfonate (MS-222) for 3-9 min resulted in a linear increase in hematocrit.2. Handling of unanesthetized trout caused a higher and more variable hematocrit reading than did exposure to MS-222 for up to 3 min.3. The range and standard error of hematocrit readings was smallest in trout treated with MS-222 for 1 min.
Standardized strapdown inertial component modularity study, volume 2
NASA Technical Reports Server (NTRS)
Feldman, J.
1974-01-01
To obtain cost effective strapdown navigation, guidance and stabilization systems to meet anticipated future needs a standardized modularized strapdown system concept is proposed. Three performance classes, high, medium and low, are suggested to meet the range of applications. Candidate inertial instruments are selected and analyzed for interface compatibility. Electronic packaging and processing, materials and thermal considerations applying to the three classes are discussed and recommendations advanced. Opportunities for automatic fault detection and redundancy are presented. The smallest gyro and accelerometer modules are projected as requiring a volume of 26 cubic inches and 23.6 cubic inches, respectively. Corresponding power dissipation is projected as 5 watts, and 2.6 watts respectively.
Improved Bond Strength of Cyanoacrylate Adhesives Through Nanostructured Chromium Adhesion Layers
NASA Astrophysics Data System (ADS)
Gobble, Kyle; Stark, Amelia; Stagon, Stephen P.
2016-09-01
The performance of many consumer products suffers due to weak and inconsistent bonds formed to low surface energy polymer materials, such as polyolefin-based high-density polyethylene (HDPE), with adhesives, such as cyanoacrylate. In this letter, we present an industrially relevant means of increasing bond shear strength and consistency through vacuum metallization of chromium thin films and nanorods, using HDPE as a prototype material and cyanoacrylate as a prototype adhesive. For the as received HDPE surfaces, unmodified bond shear strength is shown to be only 0.20 MPa with a standard deviation of 14 %. When Cr metallization layers are added onto the HDPE at thicknesses of 50 nm or less, nanorod-structured coatings outperform continuous films and have a maximum bond shear strength of 0.96 MPa with a standard deviation of 7 %. When the metallization layer is greater than 50 nm thick, continuous films demonstrate greater performance than nanorod coatings and have a maximum shear strength of 1.03 MPa with a standard deviation of 6 %. Further, when the combination of surface roughening with P400 grit sandpaper and metallization is used, 100-nm-thick nanorod coatings show a tenfold increase in shear strength over the baseline, reaching a maximum of 2.03 MPa with a standard deviation of only 3 %. The substantial increase in shear strength through metallization, and the combination of roughening with metallization, may have wide-reaching implications in consumer products which utilize low surface energy plastics.
Zhao, Pengxiang; Zhou, Suhong
2018-01-01
Traditionally, static units of analysis such as administrative units are used when studying obesity. However, using these fixed contextual units ignores environmental influences experienced by individuals in areas beyond their residential neighborhood and may render the results unreliable. This problem has been articulated as the uncertain geographic context problem (UGCoP). This study investigates the UGCoP through exploring the relationships between the built environment and obesity based on individuals’ activity space. First, a survey was conducted to collect individuals’ daily activity and weight information in Guangzhou in January 2016. Then, the data were used to calculate and compare the values of several built environment variables based on seven activity space delineations, including home buffers, workplace buffers (WPB), fitness place buffers (FPB), the standard deviational ellipse at two standard deviations (SDE2), the weighted standard deviational ellipse at two standard deviations (WSDE2), the minimum convex polygon (MCP), and road network buffers (RNB). Lastly, we conducted comparative analysis and regression analysis based on different activity space measures. The results indicate that significant differences exist between variables obtained with different activity space delineations. Further, regression analyses show that the activity space delineations used in the analysis have a significant influence on the results concerning the relationships between the built environment and obesity. The study sheds light on the UGCoP in analyzing the relationships between obesity and the built environment. PMID:29439392
Role of a Standardized Prism Under Cover Test in the Assessment of Dissociated Vertical Deviation.
Klaehn, Lindsay D; Hatt, Sarah R; Leske, David A; Holmes, Jonathan M
2018-03-01
Dissociated vertical deviation (DVD) is commonly measured using a prism and alternate cover test (PACT), but some providers use a prism under cover test (PUCT). The aim of this study was to compare a standardized PUCT measurement with a PACT measurement, for assessing the magnitude of DVD. Thirty-six patients with a clinical diagnosis of DVD underwent measurement of the angle of deviation with the PACT, fixing with the habitually fixing eye, and with PUCT, fixing both right and left eyes. The PUCT was standardized, using a 10-second cover for each prism magnitude, until the deviation was neutralized. The magnitude of hyperdeviation by PACT and PUCT was compared for the non-fixing eye, using paired non-parametric tests. The frequency of discrepancies more than 4 prism diopters (PD) between PACT and PUCT was calculated. The magnitude of hyperdeviation was greater when measured with PUCT (range 8PD hypodeviation to 20PD hyperdeviation) vs. PACT (18PD hypodeviation to 25PD hyperdeviation) with a median difference of 4.5PD (range -5PD to 21PD); P < 0.0001. Eighteen (50%) of 36 measurements elicited >4PD hyperdeviation (or >4PD less hypodeviation) by PUCT than by PACT. A standardized 10-second PUCT yields greater values than a prism and alternate cover test in the majority of patients with DVD, providing better quantification of the severity of DVD, which may be important for management decisions.
An intelligent switch with back-propagation neural network based hybrid power system
NASA Astrophysics Data System (ADS)
Perdana, R. H. Y.; Fibriana, F.
2018-03-01
The consumption of conventional energy such as fossil fuels plays the critical role in the global warming issues. The carbon dioxide, methane, nitrous oxide, etc. could lead the greenhouse effects and change the climate pattern. In fact, 77% of the electrical energy is generated from fossil fuels combustion. Therefore, it is necessary to use the renewable energy sources for reducing the conventional energy consumption regarding electricity generation. This paper presents an intelligent switch to combine both energy resources, i.e., the solar panels as the renewable energy with the conventional energy from the State Electricity Enterprise (PLN). The artificial intelligence technology with the back-propagation neural network was designed to control the flow of energy that is distributed dynamically based on renewable energy generation. By the continuous monitoring on each load and source, the dynamic pattern of the intelligent switch was better than the conventional switching method. The first experimental results for 60 W solar panels showed the standard deviation of the trial at 0.7 and standard deviation of the experiment at 0.28. The second operation for a 900 W of solar panel obtained the standard deviation of the trial at 0.05 and 0.18 for the standard deviation of the experiment. Moreover, the accuracy reached 83% using this method. By the combination of the back-propagation neural network with the observation of energy usage of the load using wireless sensor network, each load can be evenly distributed and will impact on the reduction of conventional energy usage.
40 CFR 792.81 - Standard operating procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 33 2013-07-01 2013-07-01 false Standard operating procedures. 792.81... operating procedures. (a) A testing facility shall have standard operating procedures in writing, setting... data generated in the course of a study. All deviations in a study from standard operating procedures...
40 CFR 792.81 - Standard operating procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 33 2012-07-01 2012-07-01 false Standard operating procedures. 792.81... operating procedures. (a) A testing facility shall have standard operating procedures in writing, setting... data generated in the course of a study. All deviations in a study from standard operating procedures...
40 CFR 792.81 - Standard operating procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 32 2014-07-01 2014-07-01 false Standard operating procedures. 792.81... operating procedures. (a) A testing facility shall have standard operating procedures in writing, setting... data generated in the course of a study. All deviations in a study from standard operating procedures...
Analytical probabilistic proton dose calculation and range uncertainties
NASA Astrophysics Data System (ADS)
Bangert, M.; Hennig, P.; Oelfke, U.
2014-03-01
We introduce the concept of analytical probabilistic modeling (APM) to calculate the mean and the standard deviation of intensity-modulated proton dose distributions under the influence of range uncertainties in closed form. For APM, range uncertainties are modeled with a multivariate Normal distribution p(z) over the radiological depths z. A pencil beam algorithm that parameterizes the proton depth dose d(z) with a weighted superposition of ten Gaussians is used. Hence, the integrals ∫ dz p(z) d(z) and ∫ dz p(z) d(z)2 required for the calculation of the expected value and standard deviation of the dose remain analytically tractable and can be efficiently evaluated. The means μk, widths δk, and weights ωk of the Gaussian components parameterizing the depth dose curves are found with least squares fits for all available proton ranges. We observe less than 0.3% average deviation of the Gaussian parameterizations from the original proton depth dose curves. Consequently, APM yields high accuracy estimates for the expected value and standard deviation of intensity-modulated proton dose distributions for two dimensional test cases. APM can accommodate arbitrary correlation models and account for the different nature of random and systematic errors in fractionated radiation therapy. Beneficial applications of APM in robust planning are feasible.
49 CFR 192.943 - When can an operator deviate from these reassessment intervals?
Code of Federal Regulations, 2010 CFR
2010-10-01
... (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity Management § 192.943 When can an operator deviate from these reassessment...
40 CFR 63.1455 - What reports must I submit and when?
Code of Federal Regulations, 2010 CFR
2010-07-01
... from any emission limitations (emission limit, operating limit, opacity limit) that applies to you and... that there were no deviations from the emission limitations, work practice standards, or operation and... deviation from an emission limitation (emission limit, operating limit, opacity limit) and for each...
Using an external gating signal to estimate noise in PET with an emphasis on tracer avid tumors
NASA Astrophysics Data System (ADS)
Schmidtlein, C. R.; Beattie, B. J.; Bailey, D. L.; Akhurst, T. J.; Wang, W.; Gönen, M.; Kirov, A. S.; Humm, J. L.
2010-10-01
The purpose of this study is to establish and validate a methodology for estimating the standard deviation of voxels with large activity concentrations within a PET image using replicate imaging that is immediately available for use in the clinic. To do this, ensembles of voxels in the averaged replicate images were compared to the corresponding ensembles in images derived from summed sinograms. In addition, the replicate imaging noise estimate was compared to a noise estimate based on an ensemble of voxels within a region. To make this comparison two phantoms were used. The first phantom was a seven-chamber phantom constructed of 1 liter plastic bottles. Each chamber of this phantom was filled with a different activity concentration relative to the lowest activity concentration with ratios of 1:1, 1:1, 2:1, 2:1, 4:1, 8:1 and 16:1. The second phantom was a GE Well-Counter phantom. These phantoms were imaged and reconstructed on a GE DSTE PET/CT scanner with 2D and 3D reprojection filtered backprojection (FBP), and with 2D- and 3D-ordered subset expectation maximization (OSEM). A series of tests were applied to the resulting images that showed that the region and replicate imaging methods for estimating standard deviation were equivalent for backprojection reconstructions. Furthermore, the noise properties of the FBP algorithms allowed scaling the replicate estimates of the standard deviation by a factor of 1/\\sqrt{N}, where N is the number of replicate images, to obtain the standard deviation of the full data image. This was not the case for OSEM image reconstruction. Due to nonlinearity of the OSEM algorithm, the noise is shown to be both position and activity concentration dependent in such a way that no simple scaling factor can be used to extrapolate noise as a function of counts. The use of the Well-Counter phantom contributed to the development of a heuristic extrapolation of the noise as a function of radius in FBP. In addition, the signal-to-noise ratio for high uptake objects was confirmed to be higher with backprojection image reconstruction methods. These techniques were applied to several patient data sets acquired in either 2D or 3D mode, with 18F (FLT and FDG). Images of the standard deviation and signal-to-noise ratios were constructed and the standard deviations of the tumors' uptake were determined. Finally, a radial noise extrapolation relationship deduced in this paper was applied to patient data.
Detecting long-duration cloud contamination in hyper-temporal NDVI imagery
NASA Astrophysics Data System (ADS)
Ali, Amjad; de Bie, C. A. J. M.; Skidmore, A. K.
2013-10-01
Cloud contamination impacts on the quality of hyper-temporal NDVI imagery and its subsequent interpretation. Short-duration cloud impacts are easily removed by using quality flags and an upper envelope filter, but long-duration cloud contamination of NDVI imagery remains. In this paper, an approach that goes beyond the use of quality flags and upper envelope filtering is tested to detect when and where long-duration clouds are responsible for unreliable NDVI readings, so that a user can flag those data as missing. The study is based on MODIS Terra and the combined Terra-Aqua 16-day NDVI product for the south of Ghana, where persistent cloud cover occurs throughout the year. The combined product could be assumed to have less cloud contamination, since it is based on two images per day. Short-duration cloud effects were removed from the two products through using the adaptive Savitzky-Golay filter. Then for each 'cleaned' product an unsupervised classified map was prepared using the ISODATA algorithm, and, by class, plots were prepared to depict changes over time of the means and the standard deviations in NDVI values. By comparing plots of similar classes, long-duration cloud contamination appeared to display a decline in mean NDVI below the lower limit 95% confidence interval with a coinciding increase in standard deviation above the upper limit 95% confidence interval. Regression analysis was carried out per NDVI class in two randomly selected groups in order to statistically test standard deviation values related to long-duration cloud contamination. A decline in seasonal NDVI values (growing season) were below the lower limit of 95% confidence interval as well as a concurrent increase in standard deviation values above the upper limit of the 95% confidence interval were noted in 34 NDVI classes. The regression analysis results showed that differences in NDVI class values between the Terra and the Terra-Aqua imagery were significantly correlated (p < 0.05) with the corresponding standard deviation values of the Terra imagery in case of all NDVI classes of two selected NDVI groups. The method successfully detects long-duration cloud contamination that results in unreliable NDVI values. The approach offers scientists interested in time series analysis a method of masking by area (class) the periods when pre-cleaned NDVI values remain affected by clouds. The approach requires no additional data for execution purposes but involves unsupervised classification of the imagery to carry out the evaluation of class-specific mean NDVI and standard deviation values over time.
Pandit, Jaideep J; Dexter, Franklin
2009-06-01
At multiple facilities including some in the United Kingdom's National Health Service, the following are features of many surgical-anesthetic teams: i) there is sufficient workload for each operating room (OR) list to almost always be fully scheduled; ii) the workdays are organized such that a single surgeon is assigned to each block of time (usually 8 h); iii) one team is assigned per block; and iv) hardly ever would a team "split" to do cases in more than one OR simultaneously. We used Monte-Carlo simulation using normal and Weibull distributions to estimate the times to complete lists of cases scheduled into such 8 h sessions. For each combination of mean and standard deviation, inefficiencies of use of OR time were determined for 10 h versus 8 h of staffing. When the mean actual hours of OR time used averages < or = 8 h 25 min, 8 h of staffing has higher OR efficiency than 10 h for all combinations of standard deviation and relative cost of over-run to under-run. When mean > or = 8 h 50 min, 10 h staffing has higher OR efficiency. For 8 h 25 min < mean < 8 h 50 min, the economic break-even point depends on conditions. For example, break-even is: (a) 8 h 27 min for Weibull, standard deviation of 60 min and relative cost of over-run to under-run of 2.0 versus (b) 8 h 48 min for normal, standard deviation of 0 min and relative cost ratio of 1.50. Although the simplest decision rule would be to staff for 8 h if the mean workload is < or = 8 h 40 min and to staff for 10 h otherwise, performance was poor. For example, for the Weibull distribution with mean 8 h 40 min, standard deviation 60 min, and relative cost ratio of 2.00, the inefficiency of use of OR time would be 34% larger if staffing were planned for 8 h instead of 10 h. For surgical teams with 8 h sessions, use the following decision rule for anesthesiology and OR nurse staffing. If actual hours of OR time used averages < or = 8 h 25 min, plan 8 h staffing. If average > or = 8 h 50 min, plan 10 h staffing. For averages in between, perform the full analysis of McIntosh et al. (Anesth Analg 2006;103:1499-516).
Multi-technique comparison of troposphere zenith delays and gradients during CONT08
NASA Astrophysics Data System (ADS)
Teke, Kamil; Böhm, Johannes; Nilsson, Tobias; Schuh, Harald; Steigenberger, Peter; Dach, Rolf; Heinkelmann, Robert; Willis, Pascal; Haas, Rüdiger; García-Espada, Susana; Hobiger, Thomas; Ichikawa, Ryuichi; Shimizu, Shingo
2011-07-01
CONT08 was a 15 days campaign of continuous Very Long Baseline Interferometry (VLBI) sessions during the second half of August 2008 carried out by the International VLBI Service for Geodesy and Astrometry (IVS). In this study, VLBI estimates of troposphere zenith total delays (ZTD) and gradients during CONT08 were compared with those derived from observations with the Global Positioning System (GPS), Doppler Orbitography and Radiopositioning Integrated by Satellite (DORIS), and water vapor radiometers (WVR) co-located with the VLBI radio telescopes. Similar geophysical models were used for the analysis of the space geodetic data, whereas the parameterization for the least-squares adjustment of the space geodetic techniques was optimized for each technique. In addition to space geodetic techniques and WVR, ZTD and gradients from numerical weather models (NWM) were used from the European Centre for Medium-Range Weather Forecasts (ECMWF) (all sites), the Japan Meteorological Agency (JMA) and Cloud Resolving Storm Simulator (CReSS) (Tsukuba), and the High Resolution Limited Area Model (HIRLAM) (European sites). Biases, standard deviations, and correlation coefficients were computed between the troposphere estimates of the various techniques for all eleven CONT08 co-located sites. ZTD from space geodetic techniques generally agree at the sub-centimetre level during CONT08, and—as expected—the best agreement is found for intra-technique comparisons: between the Vienna VLBI Software and the combined IVS solutions as well as between the Center for Orbit Determination (CODE) solution and an IGS PPP time series; both intra-technique comparisons are with standard deviations of about 3-6 mm. The best inter space geodetic technique agreement of ZTD during CONT08 is found between the combined IVS and the IGS solutions with a mean standard deviation of about 6 mm over all sites, whereas the agreement with numerical weather models is between 6 and 20 mm. The standard deviations are generally larger at low latitude sites because of higher humidity, and the latter is also the reason why the standard deviations are larger at northern hemisphere stations during CONT08 in comparison to CONT02 which was observed in October 2002. The assessment of the troposphere gradients from the different techniques is not as clear because of different time intervals, different estimation properties, or different observables. However, the best inter-technique agreement is found between the IVS combined gradients and the GPS solutions with standard deviations between 0.2 and 0.7 mm.
Match statistics related to winning in the group stage of 2014 Brazil FIFA World Cup.
Liu, Hongyou; Gomez, Miguel-Ángel; Lago-Peñas, Carlos; Sampaio, Jaime
2015-01-01
Identifying match statistics that strongly contribute to winning in football matches is a very important step towards a more predictive and prescriptive performance analysis. The current study aimed to determine relationships between 24 match statistics and the match outcome (win, loss and draw) in all games and close games of the group stage of FIFA World Cup (2014, Brazil) by employing the generalised linear model. The cumulative logistic regression was run in the model taking the value of each match statistic as independent variable to predict the logarithm of the odds of winning. Relationships were assessed as effects of a two-standard-deviation increase in the value of each variable on the change in the probability of a team winning a match. Non-clinical magnitude-based inferences were employed and were evaluated by using the smallest worthwhile change. Results showed that for all the games, nine match statistics had clearly positive effects on the probability of winning (Shot, Shot on Target, Shot from Counter Attack, Shot from Inside Area, Ball Possession, Short Pass, Average Pass Streak, Aerial Advantage and Tackle), four had clearly negative effects (Shot Blocked, Cross, Dribble and Red Card), other 12 statistics had either trivial or unclear effects. While for the close games, the effects of Aerial Advantage and Yellow Card turned to trivial and clearly negative, respectively. Information from the tactical modelling can provide a more thorough and objective match understanding to coaches and performance analysts for evaluating post-match performances and for scouting upcoming oppositions.
Ultrasound sensitivity to changes in gout: a longitudinal study after two years of treatment.
Peiteado, Diana; Villalba, Alejandro; Martín-Mola, Emilio; Balsa, Alejandro; De Miguel, Eugenio
2017-01-01
The goals of our study are to evaluate the urate-lowering therapy (ULT) effect on gout ultrasound (US) lesions and to explore US sensitivity to change in gout patients. Patients with chronic and symptomatic gout, confirmed by crystal identification, were prospectively included. Clinical and US assessments were performed at baseline and after 6, 12 and 24 months of ULT. The presence of double contour sign (DCS) and US- detectable tophi were assessed in the first metatarsophalangeals, the knees and patellar tendons. The mean and standard deviation were calculated for each parameter. The correlation between the clinical and US parameters was assessed by calculating Pearson's correlation coefficient. Sensitivity to change in the US examinations was assessed by estimating the smallest detectable difference (SDD). Twenty-three consecutive patients were included (96% men; mean age 59 ± 11 years). DCS and US tophi were detected in 73.9% and 91.3% of patients at baseline. A significant parallel improvement in the serum urate, clinical parameters and US lesions was found at the follow-up assessment. The SDD values for the global DCS and tophi were 0.52 and 0.69, respectively, which were smaller than the differences achieved over the course of the two years. A significant correlation between DCS and clinical parameters was observed (r =0.49, p=0.038). Ultrasound findings in gout patients show sensitivity to change and concurrent validity with uric acid reduction after ULT in gout patients. US can be a useful tool for gout tophus burden monitoring.
From field data to volumes: constraining uncertainties in pyroclastic eruption parameters
NASA Astrophysics Data System (ADS)
Klawonn, Malin; Houghton, Bruce F.; Swanson, Donald A.; Fagents, Sarah A.; Wessel, Paul; Wolfe, Cecily J.
2014-07-01
In this study, we aim to understand the variability in eruption volume estimates derived from field studies of pyroclastic deposits. We distributed paper maps of the 1959 Kīlauea Iki tephra to 101 volcanologists worldwide, who produced hand-drawn isopachs. Across the returned maps, uncertainty in isopach areas is 7 % across the well-sampled deposit but increases to over 30 % for isopachs that are governed by the largest and smallest thickness measurements. We fit the exponential, power-law, and Weibull functions through the isopach thickness versus area1/2 values and find volume estimate variations up to a factor of 4.9 for a single map. Across all maps and methodologies, we find an average standard deviation for a total volume of s = 29 %. The volume uncertainties are largest for the most proximal ( s = 62 %) and distal field ( s = 53 %) and small for the densely sampled intermediate deposit ( s = 8 %). For the Kīlauea Iki 1959 eruption, we find that the deposit beyond the 5-cm isopach contains only 2 % of the total erupted volume, whereas the near-source deposit contains 48 % and the intermediate deposit 50 % of the total volume. Thus, the relative uncertainty within each zone impacts the total volume estimates differently. The observed uncertainties for the different deposit regions in this study illustrate a fundamental problem of estimating eruption volumes: while some methodologies may provide better fits to the isopach data or rely on fewer free parameters, the main issue remains the predictive capabilities of the empirical functions for the regions where measurements are missing.
Bacheler, N.M.; Hightower, J.E.; Burdick, S.M.; Paramore, L.M.; Buckel, J.A.; Pollock, K.H.
2010-01-01
Estimating the selectivity patterns of various fishing gears is a critical component of fisheries stock assessment due to the difficulty in obtaining representative samples from most gears. We used short-term recoveries (n = 3587) of tagged red drum Sciaenops ocellatus to directly estimate age- and length-based selectivity patterns using generalized linear models. The most parsimonious models were selected using AIC, and standard deviations were estimated using simulations. Selectivity of red drum was dependent upon the regulation period in which the fish was caught, the gear used to catch the fish (i.e., hook-and-line, gill nets, pound nets), and the fate of the fish upon recovery (i.e., harvested or released); models including all first-order interactions between main effects outperformed models without interactions. Selectivity of harvested fish was generally dome-shaped and shifted toward larger, older fish in response to regulation changes. Selectivity of caught-and-released red drum was highest on the youngest and smallest fish in the early and middle regulation periods, but increased on larger, legal-sized fish in the late regulation period. These results suggest that catch-and-release mortality has consistently been high for small, young red drum, but has recently become more common in larger, older fish. This method of estimating selectivity from short-term tag recoveries is valuable because it is simpler than full tag-return models, and may be more robust because yearly fishing and natural mortality rates do not need to be modeled and estimated. ?? 2009 Elsevier B.V.
Burdick, Summer M.; Hightower, Joseph E.; Bacheler, Nathan M.; Paramore, Lee M.; Buckel, Jeffrey A.; Pollock, Kenneth H.
2010-01-01
Estimating the selectivity patterns of various fishing gears is a critical component of fisheries stock assessment due to the difficulty in obtaining representative samples from most gears. We used short-term recoveries (n = 3587) of tagged red drum Sciaenops ocellatus to directly estimate age- and length-based selectivity patterns using generalized linear models. The most parsimonious models were selected using AIC, and standard deviations were estimated using simulations. Selectivity of red drum was dependent upon the regulation period in which the fish was caught, the gear used to catch the fish (i.e., hook-and-line, gill nets, pound nets), and the fate of the fish upon recovery (i.e., harvested or released); models including all first-order interactions between main effects outperformed models without interactions. Selectivity of harvested fish was generally dome-shaped and shifted toward larger, older fish in response to regulation changes. Selectivity of caught-and-released red drum was highest on the youngest and smallest fish in the early and middle regulation periods, but increased on larger, legal-sized fish in the late regulation period. These results suggest that catch-and-release mortality has consistently been high for small, young red drum, but has recently become more common in larger, older fish. This method of estimating selectivity from short-term tag recoveries is valuable because it is simpler than full tag-return models, and may be more robust because yearly fishing and natural mortality rates do not need to be modeled and estimated.
Brüllmann, D D; d'Hoedt, B
2011-05-01
The aim of this study was to illustrate the influence of digital filters on the signal-to-noise ratio (SNR) and modulation transfer function (MTF) of digital images. The article will address image pre-processing that may be beneficial for the production of clinically useful digital radiographs with lower radiation dose. Three filters, an arithmetic mean filter, a median filter and a Gaussian filter (standard deviation (SD) = 0.4), with kernel sizes of 3 × 3 pixels and 5 × 5 pixels were tested. Synthetic images with exactly increasing amounts of Gaussian noise were created to gather linear regression of SNR before and after application of digital filters. Artificial stripe patterns with defined amounts of line pairs per millimetre were used to calculate MTF before and after the application of the digital filters. The Gaussian filter with a 5 × 5 kernel size caused the highest noise suppression (SNR increased from 2.22, measured in the synthetic image, to 11.31 in the filtered image). The smallest noise reduction was found with the 3 × 3 median filter. The application of the median filters resulted in no changes in MTF at the different resolutions but did result in the deletion of smaller structures. The 5 × 5 Gaussian filter and the 5 × 5 arithmetic mean filter showed the strongest changes of MTF. The application of digital filters can improve the SNR of a digital sensor; however, MTF can be adversely affected. As such, imaging systems should not be judged solely on their quoted spatial resolutions because pre-processing may influence image quality.
Lee, Kwang-Sig; Park, Eun-Cheol
2016-07-01
The purpose of this study was to evaluate the cost effectiveness of colorectal cancer screening interventions with their effects on health disparity being considered. Markov cohort simulation was conducted with the cycle/duration of 1/40 year(s). Data came from the results of randomized trials and others. Participants were hypothetical cohorts aged 50 years as of year 2013 in 16 Korean provinces. The interventions until the age of 80 were annual organized fecal occult blood test (FOBT) (standard screening), annual FOBT with basic reminders for provinces with higher mortalities than the national average (targeted reminder) and annual FOBT with basic/enhanced reminders for all provinces (universal reminder 1 and 2). The comparison was non-screening, the outcome was quality-adjusted life years, and only medical costs for screening and treatment were considered from a societal perspective. The Atkinson incremental cost effectiveness ratio (Atkinson ICER), the incremental cost effectiveness ratio adjusted by the Atkinson Inequality Index, was used to evaluate the cost effectiveness of the four interventions with their impacts on regional health disparity being considered. Health disparity was smallest (or greatest) in non-screening (or the standard screening). The targeted reminder had smaller health disparity, and smaller Atkinson ICER with respect to standard screening, than did the universal reminder 1 and 2. The targeted reminder might be more cost effective than the universal reminders with their effects on health disparity being considered. This study helps to develop promotional effort for colorectal cancer screening with both the greatest cost effectiveness and the smallest health disparity.
Aaltonen, T; Álvarez González, B; Amerio, S; Amidei, D; Anastassov, A; Annovi, A; Antos, J; Apollinari, G; Appel, J A; Arisawa, T; Artikov, A; Asaadi, J; Ashmanskas, W; Auerbach, B; Aurisano, A; Azfar, F; Badgett, W; Bae, T; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Barria, P; Bartos, P; Bauce, M; Bedeschi, F; Behari, S; Bellettini, G; Bellinger, J; Benjamin, D; Beretvas, A; Bhatti, A; Binkley, M E; Bisello, D; Bizjak, I; Bland, K R; Blumenfeld, B; Bocci, A; Bodek, A; Bortoletto, D; Boudreau, J; Boveia, A; Brigliadori, L; Bromberg, C; Brucken, E; Budagov, J; Budd, H S; Burkett, K; Busetto, G; Bussey, P; Buzatu, A; Calamba, A; Calancha, C; Camarda, S; Campanelli, M; Campbell, M; Canelli, F; Carls, B; Carlsmith, D; Carosi, R; Carrillo, S; Carron, S; Casal, B; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavaliere, V; Cavalli-Sforza, M; Cerri, A; Cerrito, L; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Chlebana, F; Cho, K; Chokheli, D; Chung, W H; Chung, Y S; Ciocci, M A; Clark, A; Clarke, C; Compostella, G; Convery, M E; Conway, J; Corbo, M; Cordelli, M; Cox, C A; Cox, D J; Crescioli, F; Cuevas, J; Culbertson, R; Dagenhart, D; d'Ascenzo, N; Datta, M; de Barbaro, P; Dell'Orso, M; Demortier, L; Deninno, M; Devoto, F; d'Errico, M; Di Canto, A; Di Ruzza, B; Dittmann, J R; D'Onofrio, M; Donati, S; Dong, P; Dorigo, M; Dorigo, T; Ebina, K; Elagin, A; Eppig, A; Erbacher, R; Errede, S; Ershaidat, N; Eusebi, R; Farrington, S; Feindt, M; Fernandez, J P; Ferrazza, C; Field, R; Flanagan, G; Forrest, R; Frank, M J; Franklin, M; Freeman, J C; Funakoshi, Y; Furic, I; Gallinaro, M; Garcia, J E; Garfinkel, A F; Garosi, P; Gerberich, H; Gerchtein, E; Giagu, S; Giakoumopoulou, V; Giannetti, P; Gibson, K; Ginsburg, C M; Giokaris, N; Giromini, P; Giurgiu, G; Glagolev, V; Glenzinski, D; Gold, M; Goldin, D; Goldschmidt, N; Golossanov, A; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González, O; Gorelov, I; Goshaw, A T; Goulianos, K; Grinstein, S; Grosso-Pilcher, C; Group, R C; Guimaraes da Costa, J; Hahn, S R; Halkiadakis, E; Hamaguchi, A; Han, J Y; Happacher, F; Hara, K; Hare, D; Hare, M; Harr, R F; Hatakeyama, K; Hays, C; Heck, M; Heinrich, J; Herndon, M; Hewamanage, S; Hocker, A; Hopkins, W; Horn, D; Hou, S; Hughes, R E; Hurwitz, M; Husemann, U; Hussain, N; Hussein, M; Huston, J; Introzzi, G; Iori, M; Ivanov, A; James, E; Jang, D; Jayatilaka, B; Jeans, D T; Jeon, E J; Jindariani, S; Jones, M; Joo, K K; Jun, S Y; Junk, T R; Kamon, T; Karchin, P E; Kasmi, A; Kato, Y; Ketchum, W; Keung, J; Khotilovich, V; Kilminster, B; Kim, D H; Kim, H S; Kim, J E; Kim, M J; Kim, S B; Kim, S H; Kim, Y K; Kim, Y J; Kimura, N; Kirby, M; Klimenko, S; Knoepfel, K; Kondo, K; Kong, D J; Konigsberg, J; Kotwal, A V; Kreps, M; Kroll, J; Krop, D; Kruse, M; Krutelyov, V; Kuhr, T; Kurata, M; Kwang, S; Laasanen, A T; Lami, S; Lammel, S; Lancaster, M; Lander, R L; Lannon, K; Lath, A; Latino, G; LeCompte, T; Lee, E; Lee, H S; Lee, J S; Lee, S W; Leo, S; Leone, S; Lewis, J D; Limosani, A; Lin, C-J; Lindgren, M; Lipeles, E; Lister, A; Litvintsev, D O; Liu, C; Liu, H; Liu, Q; Liu, T; Lockwitz, S; Loginov, A; Lucchesi, D; Lueck, J; Lujan, P; Lukens, P; Lungu, G; Lys, J; Lysak, R; Madrak, R; Maeshima, K; Maestro, P; Malik, S; Manca, G; Manousakis-Katsikakis, A; Margaroli, F; Marino, C; Martínez, M; Mastrandrea, P; Matera, K; Mattson, M E; Mazzacane, A; Mazzanti, P; McFarland, K S; McIntyre, P; McNulty, R; Mehta, A; Mehtala, P; Mesropian, C; Miao, T; Mietlicki, D; Mitra, A; Miyake, H; Moed, S; Moggi, N; Mondragon, M N; Moon, C S; Moore, R; Morello, M J; Morlock, J; Movilla Fernandez, P; Mukherjee, A; Muller, Th; Murat, P; Mussini, M; Nachtman, J; Nagai, Y; Naganoma, J; Nakano, I; Napier, A; Nett, J; Neu, C; Neubauer, M S; Nielsen, J; Nodulman, L; Noh, S Y; Norniella, O; Oakes, L; Oh, S H; Oh, Y D; Oksuzian, I; Okusawa, T; Orava, R; Ortolan, L; Pagan Griso, S; Pagliarone, C; Palencia, E; Papadimitriou, V; Paramonov, A A; Patrick, J; Pauletta, G; Paulini, M; Paus, C; Pellett, D E; Penzo, A; Phillips, T J; Piacentino, G; Pianori, E; Pilot, J; Pitts, K; Plager, C; Pondrom, L; Poprocki, S; Potamianos, K; Prokoshin, F; Pranko, A; Ptohos, F; Punzi, G; Rahaman, A; Ramakrishnan, V; Ranjan, N; Redondo, I; Renton, P; Rescigno, M; Riddick, T; Rimondi, F; Ristori, L; Robson, A; Rodrigo, T; Rodriguez, T; Rogers, E; Rolli, S; Roser, R; Ruffini, F; Ruiz, A; Russ, J; Rusu, V; Safonov, A; Sakumoto, W K; Sakurai, Y; Santi, L; Sato, K; Saveliev, V; Savoy-Navarro, A; Schlabach, P; Schmidt, A; Schmidt, E E; Schwarz, T; Scodellaro, L; Scribano, A; Scuri, F; Seidel, S; Seiya, Y; Semenov, A; Sforza, F; Shalhout, S Z; Shears, T; Shepard, P F; Shimojima, M; Shochet, M; Shreyber-Tecker, I; Simonenko, A; Sinervo, P; Sliwa, K; Smith, J R; Snider, F D; Soha, A; Sorin, V; Song, H; Squillacioti, P; Stancari, M; St Denis, R; Stelzer, B; Stelzer-Chilton, O; Stentz, D; Strologas, J; Strycker, G L; Sudo, Y; Sukhanov, A; Suslov, I; Takemasa, K; Takeuchi, Y; Tang, J; Tecchio, M; Teng, P K; Thom, J; Thome, J; Thompson, G A; Thomson, E; Tipton, P; Toback, D; Tokar, S; Tollefson, K; Tomura, T; Tonelli, D; Torre, S; Torretta, D; Totaro, P; Trovato, M; Ukegawa, F; Uozumi, S; Varganov, A; Vázquez, F; Velev, G; Vellidis, C; Vidal, M; Vila, I; Vilar, R; Vizán, J; Vogel, M; Volpi, G; Wagner, P; Wagner, R L; Wakisaka, T; Wallny, R; Wang, S M; Warburton, A; Waters, D; Wester, W C; Whiteson, D; Wicklund, A B; Wicklund, E; Wilbur, S; Wick, F; Williams, H H; Wilson, J S; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolfe, H; Wright, T; Wu, X; Wu, Z; Yamamoto, K; Yamato, D; Yang, T; Yang, U K; Yang, Y C; Yao, W-M; Yeh, G P; Yi, K; Yoh, J; Yorita, K; Yoshida, T; Yu, G B; Yu, I; Yu, S S; Yun, J C; Zanetti, A; Zeng, Y; Zhou, C; Zucchelli, S
2012-09-14
We combine the results of searches for the standard model (SM) Higgs boson based on the full CDF Run II data set obtained from sqrt[s]=1.96 TeV pp collisions at the Fermilab Tevatron corresponding to an integrated luminosity of 9.45 fb(-1). The searches are conducted for Higgs bosons that are produced in association with a W or Z boson, have masses in the range 90-150 GeV/c(2), and decay into bb pairs. An excess of data is present that is inconsistent with the background prediction at the level of 2.5 standard deviations (the most significant local excess is 2.7 standard deviations).
Persistence of depressive symptoms and gait speed recovery in older adults after hip fracture.
Rathbun, Alan M; Shardell, Michelle D; Stuart, Elizabeth A; Gruber-Baldini, Ann L; Orwig, Denise; Ostir, Glenn V; Hicks, Gregory E; Hochberg, Marc C; Magaziner, Jay
2018-07-01
Depression after hip fracture in older adults is associated with worse physical performance; however, depressive symptoms are dynamic, fluctuating during the recovery period. The study aim was to determine how the persistence of depressive symptoms over time cumulatively affects the recovery of physical performance. Marginal structural models estimated the cumulative effect of persistence of depressive symptoms on gait speed during hip fracture recovery among older adults (n = 284) enrolled in the Baltimore Hip Studies 7th cohort. Depressive symptoms at baseline and at 2-month and 6-month postadmission for hip fracture were evaluated by using the Center for Epidemiological Studies Depression Scale, and persistence of symptoms was assessed as a time-averaged severity lagged to standardized 3 m gait speed at 2, 6, and 12 months. A 1-unit increase in time-averaged Center for Epidemiological Studies Depression score was associated with a mean difference in gait speed of -0.0076 standard deviations (95% confidence interval [CI]: -0.0184, 0.0032; P = .166). The association was largest in magnitude from baseline to 6 months: -0.0144 standard deviations (95% CI: -0.0303, 0.0015; P = 0.076). Associations for the other time intervals were smaller: -0.0028 standard deviations (95% CI: -0.0138, 0.0083; P = .621) at 2 months and -0.0121 standard deviations (95% CI: -0.0324, 0.0082; P = .238) at 12 months. Although not statistically significant, the magnitude of the numerical estimates suggests that expressing more depressive symptoms during the first 6 months after hip fracture has a meaningful impact on functional recovery. Copyright © 2018 John Wiley & Sons, Ltd.
Hendriks, A Jan; Awkerman, Jill A; de Zwart, Dick; Huijbregts, Mark A J
2013-11-01
While variable sensitivity of model species to common toxicants has been addressed in previous studies, a systematic analysis of inter-species variability for different test types, modes of action and species is as of yet lacking. Hence, the aim of the present study was to identify similarities and differences in contaminant levels affecting cold-blooded and warm-blooded species administered via different routes. To that end, data on lethal water concentrations LC50, tissue residues LR50 and oral doses LD50 were collected from databases, each representing the largest of its kind. LC50 data were multiplied by a bioconcentration factor (BCF) to convert them to internal concentrations that allow for comparison among species. For each endpoint data set, we calculated the mean and standard deviation of species' lethal level per compound. Next, the means and standard deviations were averaged by mode of action. Both the means and standard deviations calculated depended on the number of species tested, which is at odds with quality standard setting procedures. Means calculated from (BCF) LC50, LR50 and LD50 were largely similar, suggesting that different administration routes roughly yield similar internal levels. Levels for compounds interfering biochemically with elementary life processes were about one order of magnitude below that of narcotics disturbing membranes, and neurotoxic pesticides and dioxins induced death in even lower amounts. Standard deviations for LD50 data were similar across modes of action, while variability of LC50 values was lower for narcotics than for substances with a specific mode of action. The study indicates several directions to go for efficient use of available data in risk assessment and reduction of species testing. Copyright © 2013 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Torres, T. E.; Ibarra, M. R.; Departamento de Física de la Materia Condensada, Facultad de Ciencias, Universidad de Zaragoza, 50009 Zaragoza
2015-11-14
We report a systematic study on the structural and magnetic properties of Co{sub x}Fe{sub 3−x}O{sub 4} magnetic nanoparticles with sizes between 5 and 25 nm, prepared by thermal decomposition of Fe(acac){sub 3} and Co(acac){sub 2}. The large magneto-crystalline anisotropy of the synthesized particles resulted in high blocking temperatures (42 K < T{sub B} < 345 K for 5 < d < 13 nm) and large coercive fields (H{sub C} ≈ 1600 kA/m for T = 5 K). The smallest particles (〈d〉=5 nm) revealed the existence of a magnetically hard, spin-disordered surface. The thermal dependence of static and dynamic magnetic properties of the whole series of samples could be explained within the Neel–Arrhenius relaxation framework by including the thermal dependencemore » of the magnetocrystalline anisotropy constant K{sub 1}(T), without the need of ad-hoc corrections. This approach, using the empirical Brükhatov-Kirensky relation, provided K{sub 1}(0) values very similar to the bulk material from either static or dynamic magnetic measurements, as well as realistic values for the response times (τ{sub 0} ≈ 10{sup −10}s). Deviations from the bulk anisotropy values found for the smallest particles could be qualitatively explained based on Zener's relation between K{sub 1}(T) and M(T)« less
Technology research for strapdown inertial experiment and digital flight control and guidance
NASA Technical Reports Server (NTRS)
Carestia, R. A.; Cottrell, D. E.
1985-01-01
A helicopter flight-test program to evaluate the performance of Honeywell's Tetrad - a strapdown, laser gyro, inertial navitation system is discussed. The results of 34 flights showed a mean final navigational velocity error of 5.06 knots, with a standard deviation of 3.84 knots; a corresponding mean final position error of 2.66 n.mi., with a standard deviation of 1.48 n.m.; and a modeled mean-position-error growth rate for the 34 tests of 1.96 knots, with a standard deviation of 1.09 knots. Tetrad's four-ring laser gyros provided reliable and accurate angular rate sensing during the test program and on sensor failures were detected during the evaluation. Criteria suitable for investigating cockpit systems in rotorcraft were developed. This criteria led to the development of two basic simulators. The first was a standard simulator which could be used to obtain baseline information for studying pilot workload and interactions. The second was an advanced simulator which integrated the RODAAS developed by Honeywell into this simulator. The second area also included surveying the aerospace industry to determine the level of use and impact of microcomputers and related components on avionics systems.
The Bnl Muon Anomalous Magnetic Moment Measurement
NASA Astrophysics Data System (ADS)
Hertzog, David W.
2003-09-01
The E821 experiment at Brookhaven National Laboratory is designed to measure the muon magnetic anomaly, aμ, to an ultimate precision of 0.4 parts per million (ppm). Because theory can predict aμ to 0.6 ppm, and ongoing efforts aim to reduce this uncertainty, the comparison represents an important and sensitive test of new physics. At the time of this Workshop, the reported experimental result from the 1999 running period achieved a
7 CFR 32.400 - Samples of grease mohair grades; method of obtaining.
Code of Federal Regulations, 2010 CFR
2010-01-01
... standard deviation of fiber diameter of bulk sample were within the limits corresponding to the grade of... SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE COMMODITY STANDARDS AND STANDARD CONTAINER REGULATIONS PURCHASE OF GREASE MOHAIR AND MOHAIR TOP SAMPLES § 32.400 Samples of grease...
7 CFR 31.400 - Samples for wool and wool top grades; method of obtaining.
Code of Federal Regulations, 2010 CFR
2010-01-01
... average and standard deviation of fiber diameter of the bulk sample are within the limits corresponding to... MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE COMMODITY STANDARDS AND STANDARD CONTAINER REGULATIONS PURCHASE OF WOOL AND WOOL TOP SAMPLES § 31.400 Samples for wool...
49 CFR 192.913 - When may an operator deviate its program from certain requirements of this subpart?
Code of Federal Regulations, 2010 CFR
2010-10-01
... Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity Management § 192.913 When may an operator deviate its program...
Organizational Deviance and Multi-Factor Leadership
ERIC Educational Resources Information Center
Aksu, Ali
2016-01-01
Organizational deviant behaviors can be defined as behaviors that have deviated from standards and uncongenial to organization's expectations. When such behaviors have been thought to damage the organization, it can be said that reducing the deviation behaviors at minimum level is necessary for a healthy organization. The aim of this research is…
21 CFR 600.14 - Reporting of biological product deviations by licensed manufacturers.
Code of Federal Regulations, 2011 CFR
2011-04-01
... this section? (1) You, the manufacturer who holds the biological product license and who had control... 21 Food and Drugs 7 2011-04-01 2010-04-01 true Reporting of biological product deviations by... HEALTH AND HUMAN SERVICES (CONTINUED) BIOLOGICS BIOLOGICAL PRODUCTS: GENERAL Establishment Standards...
Observation of electroweak single top-quark production.
Aaltonen, T; Adelman, J; Akimoto, T; Alvarez González, B; Amerio, S; Amidei, D; Anastassov, A; Annovi, A; Antos, J; Apollinari, G; Apresyan, A; Arisawa, T; Artikov, A; Ashmanskas, W; Attal, A; Aurisano, A; Azfar, F; Badgett, W; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Barria, P; Bartsch, V; Bauer, G; Beauchemin, P-H; Bedeschi, F; Beecher, D; Behari, S; Bellettini, G; Bellinger, J; Benjamin, D; Beretvas, A; Beringer, J; Bhatti, A; Binkley, M; Bisello, D; Bizjak, I; Blair, R E; Blocker, C; Blumenfeld, B; Bocci, A; Bodek, A; Boisvert, V; Bolla, G; Bortoletto, D; Boudreau, J; Boveia, A; Brau, B; Bridgeman, A; Brigliadori, L; Bromberg, C; Brubaker, E; Budagov, J; Budd, H S; Budd, S; Burke, S; Burkett, K; Busetto, G; Bussey, P; Buzatu, A; Byrum, K L; Cabrera, S; Calancha, C; Campanelli, M; Campbell, M; Canelli, F; Canepa, A; Carls, B; Carlsmith, D; Carosi, R; Carrillo, S; Carron, S; Casal, B; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavaliere, V; Cavalli-Sforza, M; Cerri, A; Cerrito, L; Chang, S H; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Chlebana, F; Cho, K; Chokheli, D; Chou, J P; Choudalakis, G; Chuang, S H; Chung, K; Chung, W H; Chung, Y S; Chwalek, T; Ciobanu, C I; Ciocci, M A; Clark, A; Clark, D; Compostella, G; Convery, M E; Conway, J; Cordelli, M; Cortiana, G; Cox, C A; Cox, D J; Crescioli, F; Cuenca Almenar, C; Cuevas, J; Culbertson, R; Cully, J C; Dagenhart, D; Datta, M; Davies, T; de Barbaro, P; De Cecco, S; Deisher, A; De Lorenzo, G; Dell'orso, M; Deluca, C; Demortier, L; Deng, J; Deninno, M; Derwent, P F; Di Canto, P; di Giovanni, G P; Dionisi, C; Di Ruzza, B; Dittmann, J R; D'Onofrio, M; Donati, S; Dong, P; Donini, J; Dorigo, T; Dube, S; Efron, J; Elagin, A; Erbacher, R; Errede, D; Errede, S; Eusebi, R; Fang, H C; Farrington, S; Fedorko, W T; Feild, R G; Feindt, M; Fernandez, J P; Ferrazza, C; Field, R; Flanagan, G; Forrest, R; Frank, M J; Franklin, M; Freeman, J C; Furic, I; Gallinaro, M; Galyardt, J; Garberson, F; Garcia, J E; Garfinkel, A F; Garosi, P; Genser, K; Gerberich, H; Gerdes, D; Gessler, A; Giagu, S; Giakoumopoulou, V; Giannetti, P; Gibson, K; Gimmell, J L; Ginsburg, C M; Giokaris, N; Giordani, M; Giromini, P; Giunta, M; Giurgiu, G; Glagolev, V; Glenzinski, D; Gold, M; Goldschmidt, N; Golossanov, A; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González, O; Gorelov, I; Goshaw, A T; Goulianos, K; Gresele, A; Grinstein, S; Grosso-Pilcher, C; Grundler, U; Guimaraes da Costa, J; Gunay-Unalan, Z; Haber, C; Hahn, K; Hahn, S R; Halkiadakis, E; Han, B-Y; Han, J Y; Happacher, F; Hara, K; Hare, D; Hare, M; Harper, S; Harr, R F; Harris, R M; Hartz, M; Hatakeyama, K; Hays, C; Heck, M; Heijboer, A; Heinrich, J; Henderson, C; Herndon, M; Heuser, J; Hewamanage, S; Hidas, D; Hill, C S; Hirschbuehl, D; Hocker, A; Hou, S; Houlden, M; Hsu, S-C; Huffman, B T; Hughes, R E; Husemann, U; Hussein, M; Huston, J; Incandela, J; Introzzi, G; Iori, M; Ivanov, A; James, E; Jang, D; Jayatilaka, B; Jeon, E J; Jha, M K; Jindariani, S; Johnson, W; Jones, M; Joo, K K; Jun, S Y; Jung, J E; Junk, T R; Kamon, T; Kar, D; Karchin, P E; Kato, Y; Kephart, R; Keung, J; Khotilovich, V; Kilminster, B; Kim, D H; Kim, H S; Kim, H W; Kim, J E; Kim, M J; Kim, S B; Kim, S H; Kim, Y K; Kimura, N; Kirsch, L; Klimenko, S; Knuteson, B; Ko, B R; Kondo, K; Kong, D J; Konigsberg, J; Korytov, A; Kotwal, A V; Kreps, M; Kroll, J; Krop, D; Krumnack, N; Kruse, M; Krutelyov, V; Kubo, T; Kuhr, T; Kulkarni, N P; Kurata, M; Kwang, S; Laasanen, A T; Lami, S; Lammel, S; Lancaster, M; Lander, R L; Lannon, K; Lath, A; Latino, G; Lazzizzera, I; LeCompte, T; Lee, E; Lee, H S; Lee, S W; Leone, S; Lewis, J D; Lin, C-S; Linacre, J; Lindgren, M; Lipeles, E; Liss, T M; Lister, A; Litvintsev, D O; Liu, C; Liu, T; Lockyer, N S; Loginov, A; Loreti, M; Lovas, L; Lucchesi, D; Luci, C; Lueck, J; Lujan, P; Lukens, P; Lungu, G; Lyons, L; Lys, J; Lysak, R; MacQueen, D; Madrak, R; Maeshima, K; Makhoul, K; Maki, T; Maksimovic, P; Malde, S; Malik, S; Manca, G; Manousakis-Katsikakis, A; Margaroli, F; Marino, C; Marino, C P; Martin, A; Martin, V; Martínez, M; Martínez-Ballarín, R; Maruyama, T; Mastrandrea, P; Masubuchi, T; Mathis, M; Mattson, M E; Mazzanti, P; McFarland, K S; McIntyre, P; McNulty, R; Mehta, A; Mehtala, P; Menzione, A; Merkel, P; Mesropian, C; Miao, T; Miladinovic, N; Miller, R; Mills, C; Milnik, M; Mitra, A; Mitselmakher, G; Miyake, H; Moggi, N; Moon, C S; Moore, R; Morello, M J; Morlock, J; Movilla Fernandez, P; Mülmenstädt, J; Mukherjee, A; Muller, Th; Mumford, R; Murat, P; Mussini, M; Nachtman, J; Nagai, Y; Nagano, A; Naganoma, J; Nakamura, K; Nakano, I; Napier, A; Necula, V; Nett, J; Neu, C; Neubauer, M S; Neubauer, S; Nielsen, J; Nodulman, L; Norman, M; Norniella, O; Nurse, E; Oakes, L; Oh, S H; Oh, Y D; Oksuzian, I; Okusawa, T; Orava, R; Osterberg, K; Pagan Griso, S; Palencia, E; Papadimitriou, V; Papaikonomou, A; Paramonov, A A; Parks, B; Pashapour, S; Patrick, J; Pauletta, G; Paulini, M; Paus, C; Peiffer, T; Pellett, D E; Penzo, A; Phillips, T J; Piacentino, G; Pianori, E; Pinera, L; Pitts, K; Plager, C; Pondrom, L; Potamianos, K; Poukhov, O; Pounder, N; Prakoshyn, F; Pronko, A; Proudfoot, J; Ptohos, F; Pueschel, E; Punzi, G; Pursley, J; Rademacker, J; Rahaman, A; Ramakrishnan, V; Ranjan, N; Redondo, I; Renton, P; Renz, M; Rescigno, M; Richter, S; Rimondi, F; Ristori, L; Robson, A; Rodrigo, T; Rodriguez, T; Rogers, E; Rolli, S; Roser, R; Rossi, M; Rossin, R; Roy, P; Ruiz, A; Russ, J; Rusu, V; Rutherford, B; Saarikko, H; Safonov, A; Sakumoto, W K; Saltó, O; Santi, L; Sarkar, S; Sartori, L; Sato, K; Savoy-Navarro, A; Schlabach, P; Schmidt, A; Schmidt, E E; Schmidt, M A; Schmidt, M P; Schmitt, M; Schwarz, T; Scodellaro, L; Scribano, A; Scuri, F; Sedov, A; Seidel, S; Seiya, Y; Semenov, A; Sexton-Kennedy, L; Sforza, F; Sfyrla, A; Shalhout, S Z; Shears, T; Shepard, P F; Shimojima, M; Shiraishi, S; Shochet, M; Shon, Y; Shreyber, I; Sinervo, P; Sisakyan, A; Slaughter, A J; Slaunwhite, J; Sliwa, K; Smith, J R; Snider, F D; Snihur, R; Soha, A; Somalwar, S; Sorin, V; Spalding, J; Spreitzer, T; Squillacioti, P; Stanitzki, M; St Denis, R; Stelzer, B; Stelzer-Chilton, O; Stentz, D; Strologas, J; Strycker, G L; Stuart, D; Suh, J S; Sukhanov, A; Suslov, I; Suzuki, T; Taffard, A; Takashima, R; Takeuchi, Y; Tanaka, R; Tecchio, M; Teng, P K; Terashi, K; Thom, J; Thompson, A S; Thompson, G A; Thomson, E; Tipton, P; Ttito-Guzmán, P; Tkaczyk, S; Toback, D; Tokar, S; Tollefson, K; Tomura, T; Tonelli, D; Torre, S; Torretta, D; Totaro, P; Tourneur, S; Trovato, M; Tsai, S-Y; Tu, Y; Turini, N; Ukegawa, F; Vallecorsa, S; van Remortel, N; Varganov, A; Vataga, E; Vázquez, F; Velev, G; Vellidis, C; Vidal, M; Vidal, R; Vila, I; Vilar, R; Vine, T; Vogel, M; Volobouev, I; Volpi, G; Wagner, P; Wagner, R G; Wagner, R L; Wagner, W; Wagner-Kuhr, J; Wakisaka, T; Wallny, R; Wang, S M; Warburton, A; Waters, D; Weinberger, M; Weinelt, J; Wester, W C; Whitehouse, B; Whiteson, D; Wicklund, A B; Wicklund, E; Wilbur, S; Williams, G; Williams, H H; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolfe, C; Wright, T; Wu, X; Würthwein, F; Xie, S; Yagil, A; Yamamoto, K; Yamaoka, J; Yang, U K; Yang, Y C; Yao, W M; Yeh, G P; Yoh, J; Yorita, K; Yoshida, T; Yu, G B; Yu, I; Yu, S S; Yun, J C; Zanello, L; Zanetti, A; Zhang, X; Zheng, Y; Zucchelli, S
2009-08-28
We report the observation of single top-quark production using 3.2 fb(-1) of pp[over ] collision data with sqrt[s]=1.96 TeV collected by the Collider Detector at Fermilab. The significance of the observed data is 5.0 standard deviations, and the expected sensitivity for standard model production and decay is in excess of 5.9 standard deviations. Assuming m(t) = 175 GeV/c(2), we measure a cross section of 2.3(-0.5);(+0.6)(stat + syst) pb, extract the CKM matrix-element value |V(tb)| = 0.91 + or - 0.11(stat + syst) + or - 0.07(theory), and set the limit |V(tb)| > 0.71 at the 95% C.L.
Méndez-Hermida, F.; Castro-Hermida, J. A.; Ares-Mazás, E.; Kehoe, S. C.; McGuigan, K. G.
2005-01-01
The results of batch-process solar disinfection (SODIS) of Cryptosporidium parvum oocysts in water are reported. Oocyst suspensions were exposed to simulated sunlight (830 W m−2) at 40°C. Viability assays (4′,6′-diamidino-2-phenylindole [DAPI]/propidium iodide and excystation) and infectivity tests (Swiss CD-1 suckling mice) were performed. SODIS exposures of 6 and 12 h reduced oocyst infectivity from 100% to 7.5% (standard deviation = 2.3) and 0% (standard deviation = 0.0), respectively. PMID:15746372
Reliability-Based Design Optimization of a Composite Airframe Component
NASA Technical Reports Server (NTRS)
Pai, Shantaram S.; Coroneos, Rula; Patnaik, Surya N.
2011-01-01
A stochastic optimization methodology (SDO) has been developed to design airframe structural components made of metallic and composite materials. The design method accommodates uncertainties in load, strength, and material properties that are defined by distribution functions with mean values and standard deviations. A response parameter, like a failure mode, has become a function of reliability. The primitive variables like thermomechanical loads, material properties, and failure theories, as well as variables like depth of beam or thickness of a membrane, are considered random parameters with specified distribution functions defined by mean values and standard deviations.
Is there a link between cognitive abilities and environmental awareness? Cross-national evidence.
Salahodjaev, Raufhon
2018-06-05
This article explores the effect of cognitive abilities on environmental awareness using data from 119 countries for the period 2005-2015. Our findings provide pioneering confirmation that a facet of human psychology, namely cognitive ability, is positively associated with environmentalism. The empirical estimations indicate that when cognitive abilities increase by one standard deviation, climate change awareness increases by approximately 19% (slightly less than one standard deviation). This positive association remains intact when we control for other determinants of environmentalism. Copyright © 2018 Elsevier Inc. All rights reserved.
Range and Energy Straggling in Ion Beam Transport
NASA Technical Reports Server (NTRS)
Wilson, John W.; Tai, Hsiang
2000-01-01
A first-order approximation to the range and energy straggling of ion beams is given as a normal distribution for which the standard deviation is estimated from the fluctuations in energy loss events. The standard deviation is calculated by assuming scattering from free electrons with a long range cutoff parameter that depends on the mean excitation energy of the medium. The present formalism is derived by extrapolating Payne's formalism to low energy by systematic energy scaling and to greater depths of penetration by a second-order perturbation. Limited comparisons are made with experimental data.
Posttraumatic stress disorder and dementia in Holocaust survivors.
Sperling, Wolfgang; Kreil, Sebastian Konstantin; Biermann, Teresa
2011-03-01
The incidence of mental and somatic sequelae has been shown to be very high in the group of people damaged by the Holocaust. Within the context of internal research, 93 Holocaust survivors suffering from posttraumatic stress disorder have been examined. Patients suffered on average from 4.5 (standard deviation ± 1.8) somatic diagnoses as well as 1.8 (standard deviation ± 0.5) psychiatric diagnoses. A diagnosis of dementia was ascertained according to ICD-10 criteria in 14%. Vascular dementia (66%) dominated over Alzheimer's dementia (23%) and other subtypes (11%).
NASA Astrophysics Data System (ADS)
Osipova, Irina Y.; Chyzh, Igor H.
2001-06-01
The influence of eye jumps on the accuracy of estimation of Zernike coefficients from eye transverse aberration measurements was investigated. By computer modeling the ametropy and astigmatism have been examined. The standard deviation of the wave aberration function was calculated. It was determined that the standard deviation of the wave aberration function achieves the minimum value if the number of scanning points is equal to the number of eye jumps in scanning period. The recommendations for duration of measurement were worked out.
Observation of the Higgs boson decay to a pair of τ leptons with the CMS detector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sirunyan, A. M.; Tumasyan, A.; Adam, W.
Here, a measurement of the H → ττ signal strength is performed using events recorded in proton–proton collisions by the CMS experiment at the LHC in 2016 at a center-of-mass energy of 13 TeV. The data set corresponds to an integrated luminosity of 35.9 fb -1. The H → ττ signal is established with a significance of 4.9 standard deviations, to be compared to an expected significance of 4.7 standard deviations.
Discrete disorder models for many-body localization
NASA Astrophysics Data System (ADS)
Janarek, Jakub; Delande, Dominique; Zakrzewski, Jakub
2018-04-01
Using exact diagonalization technique, we investigate the many-body localization phenomenon in the 1D Heisenberg chain comparing several disorder models. In particular we consider a family of discrete distributions of disorder strengths and compare the results with the standard uniform distribution. Both statistical properties of energy levels and the long time nonergodic behavior are discussed. The results for different discrete distributions are essentially identical to those obtained for the continuous distribution, provided the disorder strength is rescaled by the standard deviation of the random distribution. Only for the binary distribution significant deviations are observed.
Observation of the Higgs boson decay to a pair of τ leptons with the CMS detector
Sirunyan, A. M.; Tumasyan, A.; Adam, W.; ...
2018-02-07
Here, a measurement of the H → ττ signal strength is performed using events recorded in proton–proton collisions by the CMS experiment at the LHC in 2016 at a center-of-mass energy of 13 TeV. The data set corresponds to an integrated luminosity of 35.9 fb -1. The H → ττ signal is established with a significance of 4.9 standard deviations, to be compared to an expected significance of 4.7 standard deviations.
Aad, G; Abbott, B; Abdallah, J; Abdel Khalek, S; Abdelalim, A A; Abdesselam, A; Abdinov, O; Abi, B; Abolins, M; Abouzeid, O S; Abramowicz, H; Abreu, H; Acerbi, E; Acharya, B S; Adamczyk, L; Adams, D L; Addy, T N; Adelman, J; Aderholz, M; Adomeit, S; Adragna, P; Adye, T; Aefsky, S; Aguilar-Saavedra, J A; Aharrouche, M; Ahlen, S P; Ahles, F; Ahmad, A; Ahsan, M; Aielli, G; Akdogan, T; Akesson, T P A; Akimoto, G; Akimov, A V; Akiyama, A; Alam, M S; Alam, M A; Albert, J; Albrand, S; Aleksa, M; Aleksandrov, I N; Alessandria, F; Alexa, C; Alexander, G; Alexandre, G; Alexopoulos, T; Alhroob, M; Aliev, M; Alimonti, G; Alison, J; Aliyev, M; Allbrooke, B M M; Allport, P P; Allwood-Spiers, S E; Almond, J; Aloisio, A; Alon, R; Alonso, A; Alvarez Gonzalez, B; Alviggi, M G; Amako, K; Amaral, P; Amelung, C; Ammosov, V V; Amorim, A; Amorós, G; Amram, N; Anastopoulos, C; Ancu, L S; Andari, N; Andeen, T; Anders, C F; Anders, G; Anderson, K J; Andreazza, A; Andrei, V; Andrieux, M-L; Anduaga, X S; Angerami, A; Anghinolfi, F; Anisenkov, A; Anjos, N; Annovi, A; Antonaki, A; Antonelli, M; Antonov, A; Antos, J; Anulli, F; Aoun, S; Aperio Bella, L; Apolle, R; Arabidze, G; Aracena, I; Arai, Y; Arce, A T H; Arfaoui, S; Arguin, J-F; Arik, E; Arik, M; Armbruster, A J; Arnaez, O; Arnal, V; Arnault, C; Artamonov, A; Artoni, G; Arutinov, D; Asai, S; Asfandiyarov, R; Ask, S; Asman, B; Asquith, L; Assamagan, K; Astbury, A; Astvatsatourov, A; Aubert, B; Auge, E; Augsten, K; Aurousseau, M; Avolio, G; Avramidou, R; Axen, D; Ay, C; Azuelos, G; Azuma, Y; Baak, M A; Baccaglioni, G; Bacci, C; Bach, A M; Bachacou, H; Bachas, K; Backes, M; Backhaus, M; Badescu, E; Bagnaia, P; Bahinipati, S; Bai, Y; Bailey, D C; Bain, T; Baines, J T; Baker, O K; Baker, M D; Baker, S; Banas, E; Banerjee, P; Banerjee, Sw; Banfi, D; Bangert, A; Bansal, V; Bansil, H S; Barak, L; Baranov, S P; Barashkou, A; Barbaro Galtieri, A; Barber, T; Barberio, E L; Barberis, D; Barbero, M; Bardin, D Y; Barillari, T; Barisonzi, M; Barklow, T; Barlow, N; Barnett, B M; Barnett, R M; Baroncelli, A; Barone, G; Barr, A J; Barreiro, F; Barreiro Guimarães da Costa, J; Barrillon, P; Bartoldus, R; Barton, A E; Bartsch, V; Bates, R L; Batkova, L; Batley, J R; Battaglia, A; Battistin, M; Bauer, F; Bawa, H S; Beale, S; Beau, T; Beauchemin, P H; Beccherle, R; Bechtle, P; Beck, H P; Becker, S; Beckingham, M; Becks, K H; Beddall, A J; Beddall, A; Bedikian, S; Bednyakov, V A; Bee, C P; Begel, M; Behar Harpaz, S; Behera, P K; Beimforde, M; Belanger-Champagne, C; Bell, P J; Bell, W H; Bella, G; Bellagamba, L; Bellina, F; Bellomo, M; Belloni, A; Beloborodova, O; Belotskiy, K; Beltramello, O; Benary, O; Benchekroun, D; Benchouk, C; Bendel, M; Benekos, N; Benhammou, Y; Benhar Noccioli, E; Benitez Garcia, J A; Benjamin, D P; Benoit, M; Bensinger, J R; Benslama, K; Bentvelsen, S; Berge, D; Bergeaas Kuutmann, E; Berger, N; Berghaus, F; Berglund, E; Beringer, J; Bernat, P; Bernhard, R; Bernius, C; Berry, T; Bertella, C; Bertin, A; Bertinelli, F; Bertolucci, F; Besana, M I; Besson, N; Bethke, S; Bhimji, W; Bianchi, R M; Bianco, M; Biebel, O; Bieniek, S P; Bierwagen, K; Biesiada, J; Biglietti, M; Bilokon, H; Bindi, M; Binet, S; Bingul, A; Bini, C; Biscarat, C; Bitenc, U; Black, K M; Blair, R E; Blanchard, J-B; Blanchot, G; Blazek, T; Blocker, C; Blocki, J; Blondel, A; Blum, W; Blumenschein, U; Bobbink, G J; Bobrovnikov, V B; Bocchetta, S S; Bocci, A; Boddy, C R; Boehler, M; Boek, J; Boelaert, N; Bogaerts, J A; Bogdanchikov, A; Bogouch, A; Bohm, C; Bohm, J; Boisvert, V; Bold, T; Boldea, V; Bolnet, N M; Bomben, M; Bona, M; Bondarenko, V G; Bondioli, M; Boonekamp, M; Booth, C N; Bordoni, S; Borer, C; Borisov, A; Borissov, G; Borjanovic, I; Borri, M; Borroni, S; Bortolotto, V; Bos, K; Boscherini, D; Bosman, M; Boterenbrood, H; Botterill, D; Bouchami, J; Boudreau, J; Bouhova-Thacker, E V; Boumediene, D; Bourdarios, C; Bousson, N; Boveia, A; Boyd, J; Boyko, I R; Bozhko, N I; Bozovic-Jelisavcic, I; Bracinik, J; Braem, A; Branchini, P; Brandenburg, G W; Brandt, A; Brandt, G; Brandt, O; Bratzler, U; Brau, B; Brau, J E; Braun, H M; Brelier, B; Bremer, J; Brenner, R; Bressler, S; Britton, D; Brochu, F M; Brock, I; Brock, R; Brodbeck, T J; Brodet, E; Broggi, F; Bromberg, C; Bronner, J; Brooijmans, G; Brooks, W K; Brown, G; Brown, H; Bruckman de Renstrom, P A; Bruncko, D; Bruneliere, R; Brunet, S; Bruni, A; Bruni, G; Bruschi, M; Buanes, T; Buat, Q; Bucci, F; Buchanan, J; Buchanan, N J; Buchholz, P; Buckingham, R M; Buckley, A G; Buda, S I; Budagov, I A; Budick, B; Büscher, V; Bugge, L; Bulekov, O; Bunse, M; Buran, T; Burckhart, H; Burdin, S; Burgess, T; Burke, S; Busato, E; Bussey, P; Buszello, C P; Butin, F; Butler, B; Butler, J M; Buttar, C M; Butterworth, J M; Buttinger, W; Cabrera Urbán, S; Caforio, D; Cakir, O; Calafiura, P; Calderini, G; Calfayan, P; Calkins, R; Caloba, L P; Caloi, R; Calvet, D; Calvet, S; Camacho Toro, R; Camarri, P; Cambiaghi, M; Cameron, D; Caminada, L M; Campana, S; Campanelli, M; Canale, V; Canelli, F; Canepa, A; Cantero, J; Capasso, L; Capeans Garrido, M D M; Caprini, I; Caprini, M; Capriotti, D; Capua, M; Caputo, R; Cardarelli, R; Carli, T; Carlino, G; Carminati, L; Caron, B; Caron, S; Carquin, E; Carrillo Montoya, G D; Carter, A A; Carter, J R; Carvalho, J; Casadei, D; Casado, M P; Cascella, M; Caso, C; Castaneda Hernandez, A M; Castaneda-Miranda, E; Castillo Gimenez, V; Castro, N F; Cataldi, G; Cataneo, F; Catinaccio, A; Catmore, J R; Cattai, A; Cattani, G; Caughron, S; Cauz, D; Cavalleri, P; Cavalli, D; Cavalli-Sforza, M; Cavasinni, V; Ceradini, F; Cerqueira, A S; Cerri, A; Cerrito, L; Cerutti, F; Cetin, S A; Cevenini, F; Chafaq, A; Chakraborty, D; Chan, K; Chapleau, B; Chapman, J D; Chapman, J W; Chareyre, E; Charlton, D G; Chavda, V; Chavez Barajas, C A; Cheatham, S; Chekanov, S; Chekulaev, S V; Chelkov, G A; Chelstowska, M A; Chen, C; Chen, H; Chen, S; Chen, T; Chen, X; Cheng, S; Cheplakov, A; Chepurnov, V F; Cherkaoui El Moursli, R; Chernyatin, V; Cheu, E; Cheung, S L; Chevalier, L; Chiefari, G; Chikovani, L; Childers, J T; Chilingarov, A; Chiodini, G; Chisholm, A S; Chislett, R T; Chizhov, M V; Choudalakis, G; Chouridou, S; Christidi, I A; Christov, A; Chromek-Burckhart, D; Chu, M L; Chudoba, J; Ciapetti, G; Ciftci, A K; Ciftci, R; Cinca, D; Cindro, V; Ciobotaru, M D; Ciocca, C; Ciocio, A; Cirilli, M; Citterio, M; Ciubancan, M; Clark, A; Clark, P J; Cleland, W; Clemens, J C; Clement, B; Clement, C; Clifft, R W; Coadou, Y; Cobal, M; Coccaro, A; Cochran, J; Coe, P; Cogan, J G; Coggeshall, J; Cogneras, E; Colas, J; Colijn, A P; Collard, C; Collins, N J; Collins-Tooth, C; Collot, J; Colon, G; Conde Muiño, P; Coniavitis, E; Conidi, M C; Consonni, M; Consonni, S M; Consorti, V; Constantinescu, S; Conta, C; Conti, G; Conventi, F; Cook, J; Cooke, M; Cooper, B D; Cooper-Sarkar, A M; Copic, K; Cornelissen, T; Corradi, M; Corriveau, F; Cortes-Gonzalez, A; Cortiana, G; Costa, G; Costa, M J; Costanzo, D; Costin, T; Côté, D; Coura Torres, R; Courneyea, L; Cowan, G; Cowden, C; Cox, B E; Cranmer, K; Crescioli, F; Cristinziani, M; Crosetti, G; Crupi, R; Crépé-Renaudin, S; Cuciuc, C-M; Cuenca Almenar, C; Cuhadar Donszelmann, T; Curatolo, M; Curtis, C J; Cuthbert, C; Cwetanski, P; Czirr, H; Czodrowski, P; Czyczula, Z; D'Auria, S; D'Onofrio, M; D'Orazio, A; Da Silva, P V M; Da Via, C; Dabrowski, W; Dai, T; Dallapiccola, C; Dam, M; Dameri, M; Damiani, D S; Danielsson, H O; Dannheim, D; Dao, V; Darbo, G; Darlea, G L; Davey, W; Davidek, T; Davidson, N; Davidson, R; Davies, E; Davies, M; Davison, A R; Davygora, Y; Dawe, E; Dawson, I; Dawson, J W; Daya, R K; De, K; de Asmundis, R; De Castro, S; De Castro Faria Salgado, P E; De Cecco, S; de Graat, J; De Groot, N; de Jong, P; De La Taille, C; De la Torre, H; De Lotto, B; de Mora, L; De Nooij, L; De Pedis, D; De Salvo, A; De Sanctis, U; De Santo, A; De Vivie De Regie, J B; De Zorzi, G; Dean, S; Dearnaley, W J; Debbe, R; Debenedetti, C; Dechenaux, B; Dedovich, D V; Degenhardt, J; Dehchar, M; Del Papa, C; Del Peso, J; Del Prete, T; Delemontex, T; Deliyergiyev, M; Dell'Acqua, A; Dell'Asta, L; Della Pietra, M; della Volpe, D; Delmastro, M; Delruelle, N; Delsart, P A; Deluca, C; Demers, S; Demichev, M; Demirkoz, B; Deng, J; Denisov, S P; Derendarz, D; Derkaoui, J E; Derue, F; Dervan, P; Desch, K; Devetak, E; Deviveiros, P O; Dewhurst, A; DeWilde, B; Dhaliwal, S; Dhullipudi, R; Di Ciaccio, A; Di Ciaccio, L; Di Girolamo, A; Di Girolamo, B; Di Luise, S; Di Mattia, A; Di Micco, B; Di Nardo, R; Di Simone, A; Di Sipio, R; Diaz, M A; Diblen, F; Diehl, E B; Dietrich, J; Dietzsch, T A; Diglio, S; Dindar Yagci, K; Dingfelder, J; Dionisi, C; Dita, P; Dita, S; Dittus, F; Djama, F; Djobava, T; do Vale, M A B; Do Valle Wemans, A; Doan, T K O; Dobbs, M; Dobinson, R; Dobos, D; Dobson, E; Dobson, M; Dodd, J; Doglioni, C; Doherty, T; Doi, Y; Dolejsi, J; Dolenc, I; Dolezal, Z; Dolgoshein, B A; Dohmae, T; Donadelli, M; Donega, M; Donini, J; Dopke, J; Doria, A; Dos Anjos, A; Dosil, M; Dotti, A; Dova, M T; Dowell, J D; Doxiadis, A D; Doyle, A T; Drasal, Z; Drees, J; Dressnandt, N; Drevermann, H; Driouichi, C; Dris, M; Dubbert, J; Dube, S; Duchovni, E; Duckeck, G; Dudarev, A; Dudziak, F; Dührssen, M; Duerdoth, I P; Duflot, L; Dufour, M-A; Dunford, M; Duran Yildiz, H; Duxfield, R; Dwuznik, M; Dydak, F; Düren, M; Ebenstein, W L; Ebke, J; Eckweiler, S; Edmonds, K; Edwards, C A; Edwards, N C; Ehrenfeld, W; Ehrich, T; Eifert, T; Eigen, G; Einsweiler, K; Eisenhandler, E; Ekelof, T; El Kacimi, M; Ellert, M; Elles, S; Ellinghaus, F; Ellis, K; Ellis, N; Elmsheuser, J; Elsing, M; Emeliyanov, D; Engelmann, R; Engl, A; Epp, B; Eppig, A; Erdmann, J; Ereditato, A; Eriksson, D; Ernst, J; Ernst, M; Ernwein, J; Errede, D; Errede, S; Ertel, E; Escalier, M; Escobar, C; Espinal Curull, X; Esposito, B; Etienne, F; Etienvre, A I; Etzion, E; Evangelakou, D; Evans, H; Fabbri, L; Fabre, C; Fakhrutdinov, R M; Falciano, S; Fang, Y; Fanti, M; Farbin, A; Farilla, A; Farley, J; Farooque, T; Farrell, S; Farrington, S M; Farthouat, P; Fassnacht, P; Fassouliotis, D; Fatholahzadeh, B; Favareto, A; Fayard, L; Fazio, S; Febbraro, R; Federic, P; Fedin, O L; Fedorko, W; Fehling-Kaschek, M; Feligioni, L; Fellmann, D; Feng, C; Feng, E J; Fenyuk, A B; Ferencei, J; Ferland, J; Fernando, W; Ferrag, S; Ferrando, J; Ferrara, V; Ferrari, A; Ferrari, P; Ferrari, R; Ferreira de Lima, D E; Ferrer, A; Ferrer, M L; Ferrere, D; Ferretti, C; Ferretto Parodi, A; Fiascaris, M; Fiedler, F; Filipčič, A; Filippas, A; Filthaut, F; Fincke-Keeler, M; Fiolhais, M C N; Fiorini, L; Firan, A; Fischer, G; Fischer, P; Fisher, M J; Flechl, M; Fleck, I; Fleckner, J; Fleischmann, P; Fleischmann, S; Flick, T; Floderus, A; Flores Castillo, L R; Flowerdew, M J; Fokitis, M; Fonseca Martin, T; Forbush, D A; Formica, A; Forti, A; Fortin, D; Foster, J M; Fournier, D; Foussat, A; Fowler, A J; Fowler, K; Fox, H; Francavilla, P; Franchino, S; Francis, D; Frank, T; Franklin, M; Franz, S; Fraternali, M; Fratina, S; French, S T; Friedrich, F; Froeschl, R; Froidevaux, D; Frost, J A; Fukunaga, C; Fullana Torregrosa, E; Fuster, J; Gabaldon, C; Gabizon, O; Gadfort, T; Gadomski, S; Gagliardi, G; Gagnon, P; Galea, C; Gallas, E J; Gallo, V; Gallop, B J; Gallus, P; Gan, K K; Gao, Y S; Gapienko, V A; Gaponenko, A; Garberson, F; Garcia-Sciveres, M; García, C; García Navarro, J E; Gardner, R W; Garelli, N; Garitaonandia, H; Garonne, V; Garvey, J; Gatti, C; Gaudio, G; Gaur, B; Gauthier, L; Gauzzi, P; Gavrilenko, I L; Gay, C; Gaycken, G; Gayde, J-C; Gazis, E N; Ge, P; Gee, C N P; Geerts, D A A; Geich-Gimbel, Ch; Gellerstedt, K; Gemme, C; Gemmell, A; Genest, M H; Gentile, S; George, M; George, S; Gerlach, P; Gershon, A; Geweniger, C; Ghazlane, H; Ghodbane, N; Giacobbe, B; Giagu, S; Giakoumopoulou, V; Giangiobbe, V; Gianotti, F; Gibbard, B; Gibson, A; Gibson, S M; Gilbert, L M; Gilewsky, V; Gillberg, D; Gillman, A R; Gingrich, D M; Ginzburg, J; Giokaris, N; Giordani, M P; Giordano, R; Giorgi, F M; Giovannini, P; Giraud, P F; Giugni, D; Giunta, M; Giusti, P; Gjelsten, B K; Gladilin, L K; Glasman, C; Glatzer, J; Glazov, A; Glitza, K W; Glonti, G L; Goddard, J R; Godfrey, J; Godlewski, J; Goebel, M; Göpfert, T; Goeringer, C; Gössling, C; Göttfert, T; Goldfarb, S; Golling, T; Gomes, A; Gomez Fajardo, L S; Gonçalo, R; Goncalves Pinto Firmino Da Costa, J; Gonella, L; Gonidec, A; Gonzalez, S; González de la Hoz, S; Gonzalez Parra, G; Gonzalez Silva, M L; Gonzalez-Sevilla, S; Goodson, J J; Goossens, L; Gorbounov, P A; Gordon, H A; Gorelov, I; Gorfine, G; Gorini, B; Gorini, E; Gorišek, A; Gornicki, E; Gorokhov, S A; Goryachev, V N; Gosdzik, B; Gosselink, M; Gostkin, M I; Gough Eschrich, I; Gouighri, M; Goujdami, D; Goulette, M P; Goussiou, A G; Goy, C; Gozpinar, S; Grabowska-Bold, I; Grafström, P; Grahn, K-J; Grancagnolo, F; Grancagnolo, S; Grassi, V; Gratchev, V; Grau, N; Gray, H M; Gray, J A; Graziani, E; Grebenyuk, O G; Greenshaw, T; Greenwood, Z D; Gregersen, K; Gregor, I M; Grenier, P; Griffiths, J; Grigalashvili, N; Grillo, A A; Grinstein, S; Grishkevich, Y V; Grivaz, J-F; Groh, M; Gross, E; Grosse-Knetter, J; Groth-Jensen, J; Grybel, K; Guarino, V J; Guest, D; Guicheney, C; Guida, A; Guindon, S; Guler, H; Gunther, J; Guo, B; Guo, J; Gupta, A; Gusakov, Y; Gushchin, V N; Gutierrez, P; Guttman, N; Gutzwiller, O; Guyot, C; Gwenlan, C; Gwilliam, C B; Haas, A; Haas, S; Haber, C; Hackenburg, R; Hadavand, H K; Hadley, D R; Haefner, P; Hahn, F; Haider, S; Hajduk, Z; Hakobyan, H; Hall, D; Haller, J; Hamacher, K; Hamal, P; Hamer, M; Hamilton, A; Hamilton, S; Han, H; Han, L; Hanagaki, K; Hanawa, K; Hance, M; Handel, C; Hanke, P; Hansen, J R; Hansen, J B; Hansen, J D; Hansen, P H; Hansson, P; Hara, K; Hare, G A; Harenberg, T; Harkusha, S; Harper, D; Harrington, R D; Harris, O M; Harrison, K; Hartert, J; Hartjes, F; Haruyama, T; Harvey, A; Hasegawa, S; Hasegawa, Y; Hassani, S; Hatch, M; Hauff, D; Haug, S; Hauschild, M; Hauser, R; Havranek, M; Hawes, B M; Hawkes, C M; Hawkings, R J; Hawkins, A D; Hawkins, D; Hayakawa, T; Hayashi, T; Hayden, D; Hayward, H S; Haywood, S J; Hazen, E; He, M; Head, S J; Hedberg, V; Heelan, L; Heim, S; Heinemann, B; Heisterkamp, S; Helary, L; Heller, C; Heller, M; Hellman, S; Hellmich, D; Helsens, C; Henderson, R C W; Henke, M; Henrichs, A; Henriques Correia, A M; Henrot-Versille, S; Henry-Couannier, F; Hensel, C; Henß, T; Hernandez, C M; Hernández Jiménez, Y; Herrberg, R; Hershenhorn, A D; Herten, G; Hertenberger, R; Hervas, L; Hesketh, G G; Hessey, N P; Higón-Rodriguez, E; Hill, D; Hill, J C; Hill, N; Hiller, K H; Hillert, S; Hillier, S J; Hinchliffe, I; Hines, E; Hirose, M; Hirsch, F; Hirschbuehl, D; Hobbs, J; Hod, N; Hodgkinson, M C; Hodgson, P; Hoecker, A; Hoeferkamp, M R; Hoffman, J; Hoffmann, D; Hohlfeld, M; Holder, M; Holmgren, S O; Holy, T; Holzbauer, J L; Homma, Y; Hong, T M; Hooft van Huysduynen, L; Horazdovsky, T; Horn, C; Horner, S; Hostachy, J-Y; Hou, S; Houlden, M A; Hoummada, A; Howarth, J; Howell, D F; Hristova, I; Hrivnac, J; Hruska, I; Hryn'ova, T; Hsu, P J; Hsu, S-C; Huang, G S; Hubacek, Z; Hubaut, F; Huegging, F; Huettmann, A; Huffman, T B; Hughes, E W; Hughes, G; Hughes-Jones, R E; Huhtinen, M; Hurst, P; Hurwitz, M; Husemann, U; Huseynov, N; Huston, J; Huth, J; Iacobucci, G; Iakovidis, G; Ibbotson, M; Ibragimov, I; Ichimiya, R; Iconomidou-Fayard, L; Idarraga, J; Iengo, P; Igonkina, O; Ikegami, Y; Ikeno, M; Ilchenko, Y; Iliadis, D; Ilic, N; Imori, M; Ince, T; Inigo-Golfin, J; Ioannou, P; Iodice, M; Ippolito, V; Irles Quiles, A; Isaksson, C; Ishikawa, A; Ishino, M; Ishmukhametov, R; Issever, C; Istin, S; Ivashin, A V; Iwanski, W; Iwasaki, H; Izen, J M; Izzo, V; Jackson, B; Jackson, J N; Jackson, P; Jaekel, M R; Jain, V; Jakobs, K; Jakobsen, S; Jakubek, J; Jana, D K; Jankowski, E; Jansen, E; Jansen, H; Jantsch, A; Janus, M; Jarlskog, G; Jeanty, L; Jelen, K; Jen-La Plante, I; Jenni, P; Jeremie, A; Jež, P; Jézéquel, S; Jha, M K; Ji, H; Ji, W; Jia, J; Jiang, Y; Jimenez Belenguer, M; Jin, G; Jin, S; Jinnouchi, O; Joergensen, M D; Joffe, D; Johansen, L G; Johansen, M; Johansson, K E; Johansson, P; Johnert, S; Johns, K A; Jon-And, K; Jones, G; Jones, R W L; Jones, T W; Jones, T J; Jonsson, O; Joram, C; Jorge, P M; Joseph, J; Jovicevic, J; Jovin, T; Ju, X; Jung, C A; Jungst, R M; Juranek, V; Jussel, P; Juste Rozas, A; Kabachenko, V V; Kabana, S; Kaci, M; Kaczmarska, A; Kadlecik, P; Kado, M; Kagan, H; Kagan, M; Kaiser, S; Kajomovitz, E; Kalinin, S; Kalinovskaya, L V; Kama, S; Kanaya, N; Kaneda, M; Kaneti, S; Kanno, T; Kantserov, V A; Kanzaki, J; Kaplan, B; Kapliy, A; Kaplon, J; Kar, D; Karagoz, M; Karnevskiy, M; Karr, K; Kartvelishvili, V; Karyukhin, A N; Kashif, L; Kasieczka, G; Kasmi, A; Kass, R D; Kastanas, A; Kataoka, M; Kataoka, Y; Katsoufis, E; Katzy, J; Kaushik, V; Kawagoe, K; Kawamoto, T; Kawamura, G; Kayl, M S; Kazanin, V A; Kazarinov, M Y; Keeler, R; Kehoe, R; Keil, M; Kekelidze, G D; Keller, J S; Kennedy, J; Kenyon, M; Kepka, O; Kerschen, N; Kerševan, B P; Kersten, S; Kessoku, K; Keung, J; Khakzad, M; Khalil-Zada, F; Khandanyan, H; Khanov, A; Kharchenko, D; Khodinov, A; Kholodenko, A G; Khomich, A; Khoo, T J; Khoriauli, G; Khoroshilov, A; Khovanskiy, N; Khovanskiy, V; Khramov, E; Khubua, J; Kim, H; Kim, M S; Kim, S H; Kimura, N; Kind, O; King, B T; King, M; King, R S B; Kirk, J; Kirsch, L E; Kiryunin, A E; Kishimoto, T; Kisielewska, D; Kittelmann, T; Kiver, A M; Kladiva, E; Klaiber-Lodewigs, J; Klein, M; Klein, U; Kleinknecht, K; Klemetti, M; Klier, A; Klimek, P; Klimentov, A; Klingenberg, R; Klinger, J A; Klinkby, E B; Klioutchnikova, T; Klok, P F; Klous, S; Kluge, E-E; Kluge, T; Kluit, P; Kluth, S; Knecht, N S; Kneringer, E; Knobloch, J; Knoops, E B F G; Knue, A; Ko, B R; Kobayashi, T; Kobel, M; Kocian, M; Kodys, P; Köneke, K; König, A C; Koenig, S; Köpke, L; Koetsveld, F; Koevesarki, P; Koffas, T; Koffeman, E; Kogan, L A; Kohn, F; Kohout, Z; Kohriki, T; Koi, T; Kokott, T; Kolachev, G M; Kolanoski, H; Kolesnikov, V; Koletsou, I; Koll, J; Kollefrath, M; Kolya, S D; Komar, A A; Komori, Y; Kondo, T; Kono, T; Kononov, A I; Konoplich, R; Konstantinidis, N; Kootz, A; Koperny, S; Korcyl, K; Kordas, K; Koreshev, V; Korn, A; Korol, A; Korolkov, I; Korolkova, E V; Korotkov, V A; Kortner, O; Kortner, S; Kostyukhin, V V; Kotamäki, M J; Kotov, S; Kotov, V M; Kotwal, A; Kourkoumelis, C; Kouskoura, V; Koutsman, A; Kowalewski, R; Kowalski, T Z; Kozanecki, W; Kozhin, A S; Kral, V; Kramarenko, V A; Kramberger, G; Krasny, M W; Krasznahorkay, A; Kraus, J; Kraus, J K; Kreisel, A; Krejci, F; Kretzschmar, J; Krieger, N; Krieger, P; Kroeninger, K; Kroha, H; Kroll, J; Kroseberg, J; Krstic, J; Kruchonak, U; Krüger, H; Kruker, T; Krumnack, N; Krumshteyn, Z V; Kruth, A; Kubota, T; Kuday, S; Kuehn, S; Kugel, A; Kuhl, T; Kuhn, D; Kukhtin, V; Kulchitsky, Y; Kuleshov, S; Kummer, C; Kuna, M; Kundu, N; Kunkle, J; Kupco, A; Kurashige, H; Kurata, M; Kurochkin, Y A; Kus, V; Kuwertz, E S; Kuze, M; Kvita, J; Kwee, R; La Rosa, A; La Rotonda, L; Labarga, L; Labbe, J; Lablak, S; Lacasta, C; Lacava, F; Lacker, H; Lacour, D; Lacuesta, V R; Ladygin, E; Lafaye, R; Laforge, B; Lagouri, T; Lai, S; Laisne, E; Lamanna, M; Lambourne, L; Lampen, C L; Lampl, W; Lancon, E; Landgraf, U; Landon, M P J; Lane, J L; Lange, C; Lankford, A J; Lanni, F; Lantzsch, K; Laplace, S; Lapoire, C; Laporte, J F; Lari, T; Larionov, A V; Larner, A; Lasseur, C; Lassnig, M; Laurelli, P; Lavorini, V; Lavrijsen, W; Laycock, P; Lazarev, A B; Le Dortz, O; Le Guirriec, E; Le Maner, C; Le Menedeu, E; Lebel, C; LeCompte, T; Ledroit-Guillon, F; Lee, H; Lee, J S H; Lee, S C; Lee, L; Lefebvre, M; Legendre, M; Leger, A; LeGeyt, B C; Legger, F; Leggett, C; Lehmacher, M; Lehmann Miotto, G; Lei, X; Leite, M A L; Leitner, R; Lellouch, D; Leltchouk, M; Lemmer, B; Lendermann, V; Leney, K J C; Lenz, T; Lenzen, G; Lenzi, B; Leonhardt, K; Leontsinis, S; Leroy, C; Lessard, J-R; Lesser, J; Lester, C G; Leung Fook Cheong, A; Levêque, J; Levin, D; Levinson, L J; Levitski, M S; Lewis, A; Lewis, G H; Leyko, A M; Leyton, M; Li, B; Li, H; Li, S; Li, X; Liang, Z; Liao, H; Liberti, B; Lichard, P; Lichtnecker, M; Lie, K; Liebig, W; Lifshitz, R; Lilley, J N; Limbach, C; Limosani, A; Limper, M; Lin, S C; Linde, F; Linnemann, J T; Lipeles, E; Lipinsky, L; Lipniacka, A; Liss, T M; Lissauer, D; Lister, A; Litke, A M; Liu, C; Liu, D; Liu, H; Liu, J B; Liu, M; Liu, Y; Livan, M; Livermore, S S A; Lleres, A; Llorente Merino, J; Lloyd, S L; Lobodzinska, E; Loch, P; Lockman, W S; Loddenkoetter, T; Loebinger, F K; Loginov, A; Loh, C W; Lohse, T; Lohwasser, K; Lokajicek, M; Loken, J; Lombardo, V P; Long, R E; Lopes, L; Lopez Mateos, D; Lorenz, J; Lorenzo Martinez, N; Losada, M; Loscutoff, P; Lo Sterzo, F; Losty, M J; Lou, X; Lounis, A; Loureiro, K F; Love, J; Love, P A; Lowe, A J; Lu, F; Lubatti, H J; Luci, C; Lucotte, A; Ludwig, A; Ludwig, D; Ludwig, I; Ludwig, J; Luehring, F; Luijckx, G; Lukas, W; Lumb, D; Luminari, L; Lund, E; Lund-Jensen, B; Lundberg, B; Lundberg, J; Lundquist, J; Lungwitz, M; Lutz, G; Lynn, D; Lys, J; Lytken, E; Ma, H; Ma, L L; Macana Goia, J A; Maccarrone, G; Macchiolo, A; Maček, B; Machado Miguens, J; Mackeprang, R; Madaras, R J; Mader, W F; Maenner, R; Maeno, T; Mättig, P; Mättig, S; Magnoni, L; Magradze, E; Mahalalel, Y; Mahboubi, K; Mahmoud, S; Mahout, G; Maiani, C; Maidantchik, C; Maio, A; Majewski, S; Makida, Y; Makovec, N; Mal, P; Malaescu, B; Malecki, Pa; Malecki, P; Maleev, V P; Malek, F; Mallik, U; Malon, D; Malone, C; Maltezos, S; Malyshev, V; Malyukov, S; Mameghani, R; Mamuzic, J; Manabe, A; Mandelli, L; Mandić, I; Mandrysch, R; Maneira, J; Mangeard, P S; Manhaes de Andrade Filho, L; Manjavidze, I D; Mann, A; Manning, P M; Manousakis-Katsikakis, A; Mansoulie, B; Manz, A; Mapelli, A; Mapelli, L; March, L; Marchand, J F; Marchese, F; Marchiori, G; Marcisovsky, M; Marino, C P; Marroquim, F; Marshall, R; Marshall, Z; Martens, F K; Marti-Garcia, S; Martin, A J; Martin, B; Martin, B; Martin, F F; Martin, J P; Martin, Ph; Martin, T A; Martin, V J; Martin dit Latour, B; Martin-Haugh, S; Martinez, M; Martinez Outschoorn, V; Martyniuk, A C; Marx, M; Marzano, F; Marzin, A; Masetti, L; Mashimo, T; Mashinistov, R; Masik, J; Maslennikov, A L; Massa, I; Massaro, G; Massol, N; Mastrandrea, P; Mastroberardino, A; Masubuchi, T; Matricon, P; Matsumoto, H; Matsunaga, H; Matsushita, T; Mattravers, C; Maugain, J M; Maurer, J; Maxfield, S J; Maximov, D A; May, E N; Mayne, A; Mazini, R; Mazur, M; Mazzanti, M; Mc Kee, S P; McCarn, A; McCarthy, R L; McCarthy, T G; McCubbin, N A; McFarlane, K W; Mcfayden, J A; McGlone, H; Mchedlidze, G; McLaren, R A; Mclaughlan, T; McMahon, S J; McPherson, R A; Meade, A; Mechnich, J; Mechtel, M; Medinnis, M; Meera-Lebbai, R; Meguro, T; Mehdiyev, R; Mehlhase, S; Mehta, A; Meier, K; Meirose, B; Melachrinos, C; Mellado Garcia, B R; Mendoza Navas, L; Meng, Z; Mengarelli, A; Menke, S; Menot, C; Meoni, E; Mercurio, K M; Mermod, P; Merola, L; Meroni, C; Merritt, F S; Merritt, H; Messina, A; Metcalfe, J; Mete, A S; Meyer, C; Meyer, C; Meyer, J-P; Meyer, J; Meyer, J; Meyer, T C; Meyer, W T; Miao, J; Michal, S; Micu, L; Middleton, R P; Migas, S; Mijović, L; Mikenberg, G; Mikestikova, M; Mikuž, M; Miller, D W; Miller, R J; Mills, W J; Mills, C; Milov, A; Milstead, D A; Milstein, D; Minaenko, A A; Miñano Moya, M; Minashvili, I A; Mincer, A I; Mindur, B; Mineev, M; Ming, Y; Mir, L M; Mirabelli, G; Miralles Verge, L; Misiejuk, A; Mitrevski, J; Mitrofanov, G Y; Mitsou, V A; Mitsui, S; Miyagawa, P S; Miyazaki, K; Mjörnmark, J U; Moa, T; Mockett, P; Moed, S; Moeller, V; Mönig, K; Möser, N; Mohapatra, S; Mohr, W; Mohrdieck-Möck, S; Moisseev, A M; Moles-Valls, R; Molina-Perez, J; Monk, J; Monnier, E; Montesano, S; Monticelli, F; Monzani, S; Moore, R W; Moorhead, G F; Mora Herrera, C; Moraes, A; Morange, N; Morel, J; Morello, G; Moreno, D; Moreno Llácer, M; Morettini, P; Morgenstern, M; Morii, M; Morin, J; Morley, A K; Mornacchi, G; Morozov, S V; Morris, J D; Morvaj, L; Moser, H G; Mosidze, M; Moss, J; Mount, R; Mountricha, E; Mouraviev, S V; Moyse, E J W; Mudrinic, M; Mueller, F; Mueller, J; Mueller, K; Müller, T A; Mueller, T; Muenstermann, D; Muir, A; Munwes, Y; Murray, W J; Mussche, I; Musto, E; Myagkov, A G; Nadal, J; Nagai, K; Nagano, K; Nagarkar, A; Nagasaka, Y; Nagel, M; Nairz, A M; Nakahama, Y; Nakamura, K; Nakamura, T; Nakano, I; Nanava, G; Napier, A; Narayan, R; Nash, M; Nation, N R; Nattermann, T; Naumann, T; Navarro, G; Neal, H A; Nebot, E; Nechaeva, P Yu; Neep, T J; Negri, A; Negri, G; Nektarijevic, S; Nelson, A; Nelson, T K; Nemecek, S; Nemethy, P; Nepomuceno, A A; Nessi, M; Neubauer, M S; Neusiedl, A; Neves, R M; Nevski, P; Newman, P R; Nguyen Thi Hong, V; Nickerson, R B; Nicolaidou, R; Nicolas, L; Nicquevert, B; Niedercorn, F; Nielsen, J; Niinikoski, T; Nikiforou, N; Nikiforov, A; Nikolaenko, V; Nikolaev, K; Nikolic-Audit, I; Nikolics, K; Nikolopoulos, K; Nilsen, H; Nilsson, P; Ninomiya, Y; Nisati, A; Nishiyama, T; Nisius, R; Nodulman, L; Nomachi, M; Nomidis, I; Nordberg, M; Nordkvist, B; Norton, P R; Novakova, J; Nozaki, M; Nozka, L; Nugent, I M; Nuncio-Quiroz, A-E; Nunes Hanninger, G; Nunnemann, T; Nurse, E; O'Brien, B J; O'Neale, S W; O'Neil, D C; O'Shea, V; Oakes, L B; Oakham, F G; Oberlack, H; Ocariz, J; Ochi, A; Oda, S; Odaka, S; Odier, J; Ogren, H; Oh, A; Oh, S H; Ohm, C C; Ohshima, T; Ohshita, H; Okada, S; Okawa, H; Okumura, Y; Okuyama, T; Olariu, A; Olcese, M; Olchevski, A G; Olivares Pino, S A; Oliveira, M; Oliveira Damazio, D; Oliver Garcia, E; Olivito, D; Olszewski, A; Olszowska, J; Omachi, C; Onofre, A; Onyisi, P U E; Oram, C J; Oreglia, M J; Oren, Y; Orestano, D; Orlando, N; Orlov, I; Oropeza Barrera, C; Orr, R S; Osculati, B; Ospanov, R; Osuna, C; Otero Y Garzon, G; Ottersbach, J P; Ouchrif, M; Ouellette, E A; Ould-Saada, F; Ouraou, A; Ouyang, Q; Ovcharova, A; Owen, M; Owen, S; Ozcan, V E; Ozturk, N; Pacheco Pages, A; Padilla Aranda, C; Pagan Griso, S; Paganis, E; Paige, F; Pais, P; Pajchel, K; Palacino, G; Paleari, C P; Palestini, S; Pallin, D; Palma, A; Palmer, J D; Pan, Y B; Panagiotopoulou, E; Panes, B; Panikashvili, N; Panitkin, S; Pantea, D; Panuskova, M; Paolone, V; Papadelis, A; Papadopoulou, Th D; Paramonov, A; Park, W; Parker, M A; Parodi, F; Parsons, J A; Parzefall, U; Pashapour, S; Pasqualucci, E; Passaggio, S; Passeri, A; Pastore, F; Pastore, Fr; Pásztor, G; Pataraia, S; Patel, N; Pater, J R; Patricelli, S; Pauly, T; Pecsy, M; Pedraza Morales, M I; Peleganchuk, S V; Peng, H; Pengo, R; Penning, B; Penson, A; Penwell, J; Perantoni, M; Perez, K; Perez Cavalcanti, T; Perez Codina, E; Pérez García-Estañ, M T; Perez Reale, V; Perini, L; Pernegger, H; Perrino, R; Perrodo, P; Persembe, S; Peshekhonov, V D; Peters, K; Petersen, B A; Petersen, J; Petersen, T C; Petit, E; Petridis, A; Petridou, C; Petrolo, E; Petrucci, F; Petschull, D; Petteni, M; Pezoa, R; Phan, A; Phillips, P W; Piacquadio, G; Picazio, A; Piccaro, E; Piccinini, M; Piec, S M; Piegaia, R; Pignotti, D T; Pilcher, J E; Pilkington, A D; Pina, J; Pinamonti, M; Pinder, A; Pinfold, J L; Ping, J; Pinto, B; Pirotte, O; Pizio, C; Placakyte, R; Plamondon, M; Pleier, M-A; Pleskach, A V; Plotnikova, E; Poblaguev, A; Poddar, S; Podlyski, F; Poggioli, L; Poghosyan, T; Pohl, M; Polci, F; Polesello, G; Policicchio, A; Polini, A; Poll, J; Polychronakos, V; Pomarede, D M; Pomeroy, D; Pommès, K; Pontecorvo, L; Pope, B G; Popeneciu, G A; Popovic, D S; Poppleton, A; Portell Bueso, X; Posch, C; Pospelov, G E; Pospisil, S; Potrap, I N; Potter, C J; Potter, C T; Poulard, G; Poveda, J; Pozdnyakov, V; Prabhu, R; Pralavorio, P; Pranko, A; Prasad, S; Pravahan, R; Prell, S; Pretzl, K; Pribyl, L; Price, D; Price, J; Price, L E; Price, M J; Prieur, D; Primavera, M; Prokofiev, K; Prokoshin, F; Protopopescu, S; Proudfoot, J; Prudent, X; Przybycien, M; Przysiezniak, H; Psoroulas, S; Ptacek, E; Pueschel, E; Purdham, J; Purohit, M; Puzo, P; Pylypchenko, Y; Qian, J; Qian, Z; Qin, Z; Quadt, A; Quarrie, D R; Quayle, W B; Quinonez, F; Raas, M; Radescu, V; Radics, B; Radloff, P; Rador, T; Ragusa, F; Rahal, G; Rahimi, A M; Rahm, D; Rajagopalan, S; Rammensee, M; Rammes, M; Randle-Conde, A S; Randrianarivony, K; Ratoff, P N; Rauscher, F; Rave, T C; Raymond, M; Read, A L; Rebuzzi, D M; Redelbach, A; Redlinger, G; Reece, R; Reeves, K; Reichold, A; Reinherz-Aronis, E; Reinsch, A; Reisinger, I; Rembser, C; Ren, Z L; Renaud, A; Rescigno, M; Resconi, S; Resende, B; Reznicek, P; Rezvani, R; Richards, A; Richter, R; Richter-Was, E; Ridel, M; Rijpstra, M; Rijssenbeek, M; Rimoldi, A; Rinaldi, L; Rios, R R; Riu, I; Rivoltella, G; Rizatdinova, F; Rizvi, E; Robertson, S H; Robichaud-Veronneau, A; Robinson, D; Robinson, J E M; Robson, A; Rocha de Lima, J G; Roda, C; Roda Dos Santos, D; Rodriguez, D; Roe, A; Roe, S; Røhne, O; Rojo, V; Rolli, S; Romaniouk, A; Romano, M; Romanov, V M; Romeo, G; Romero Adam, E; Roos, L; Ros, E; Rosati, S; Rosbach, K; Rose, A; Rose, M; Rosenbaum, G A; Rosenberg, E I; Rosendahl, P L; Rosenthal, O; Rosselet, L; Rossetti, V; Rossi, E; Rossi, L P; Rotaru, M; Roth, I; Rothberg, J; Rousseau, D; Royon, C R; Rozanov, A; Rozen, Y; Ruan, X; Rubinskiy, I; Ruckert, B; Ruckstuhl, N; Rud, V I; Rudolph, C; Rudolph, G; Rühr, F; Ruggieri, F; Ruiz-Martinez, A; Rumiantsev, V; Rumyantsev, L; Runge, K; Rurikova, Z; Rusakovich, N A; Rutherfoord, J P; Ruwiedel, C; Ruzicka, P; Ryabov, Y F; Ryadovikov, V; Ryan, P; Rybar, M; Rybkin, G; Ryder, N C; Rzaeva, S; Saavedra, A F; Sadeh, I; Sadrozinski, H F-W; Sadykov, R; Safai Tehrani, F; Sakamoto, H; Salamanna, G; Salamon, A; Saleem, M; Salihagic, D; Salnikov, A; Salt, J; Salvachua Ferrando, B M; Salvatore, D; Salvatore, F; Salvucci, A; Salzburger, A; Sampsonidis, D; Samset, B H; Sanchez, A; Sanchez Martinez, V; Sandaker, H; Sander, H G; Sanders, M P; Sandhoff, M; Sandoval, T; Sandoval, C; Sandstroem, R; Sandvoss, S; Sankey, D P C; Sansoni, A; Santamarina Rios, C; Santoni, C; Santonico, R; Santos, H; Saraiva, J G; Sarangi, T; Sarkisyan-Grinbaum, E; Sarri, F; Sartisohn, G; Sasaki, O; Sasaki, T; Sasao, N; Satsounkevitch, I; Sauvage, G; Sauvan, E; Sauvan, J B; Savard, P; Savinov, V; Savu, D O; Sawyer, L; Saxon, D H; Saxon, J; Says, L P; Sbarra, C; Sbrizzi, A; Scallon, O; Scannicchio, D A; Scarcella, M; Schaarschmidt, J; Schacht, P; Schaefer, D; Schäfer, U; Schaepe, S; Schaetzel, S; Schaffer, A C; Schaile, D; Schamberger, R D; Schamov, A G; Scharf, V; Schegelsky, V A; Scheirich, D; Schernau, M; Scherzer, M I; Schiavi, C; Schieck, J; Schioppa, M; Schlenker, S; Schlereth, J L; Schmidt, E; Schmieden, K; Schmitt, C; Schmitt, S; Schmitz, M; Schöning, A; Schott, M; Schouten, D; Schovancova, J; Schram, M; Schroeder, C; Schroer, N; Schuler, G; Schultens, M J; Schultes, J; Schultz-Coulon, H-C; Schulz, H; Schumacher, J W; Schumacher, M; Schumm, B A; Schune, Ph; Schwartzman, A; Schwemling, Ph; Schwienhorst, R; Schwierz, R; Schwindling, J; Schwindt, T; Schwoerer, M; Scifo, E; Sciolla, G; Scott, W G; Searcy, J; Sedov, G; Sedykh, E; Segura, E; Seidel, S C; Seiden, A; Seifert, F; Seixas, J M; Sekhniaidze, G; Sekula, S J; Selbach, K E; Seliverstov, D M; Sellden, B; Sellers, G; Seman, M; Semprini-Cesari, N; Serfon, C; Serin, L; Serkin, L; Seuster, R; Severini, H; Sevior, M E; Sfyrla, A; Shabalina, E; Shamim, M; Shan, L Y; Shank, J T; Shao, Q T; Shapiro, M; Shatalov, P B; Shaver, L; Shaw, K; Sherman, D; Sherwood, P; Shibata, A; Shichi, H; Shimizu, S; Shimojima, M; Shin, T; Shiyakova, M; Shmeleva, A; Shochet, M J; Short, D; Shrestha, S; Shulga, E; Shupe, M A; Sicho, P; Sidoti, A; Siegert, F; Sijacki, Dj; Silbert, O; Silva, J; Silver, Y; Silverstein, D; Silverstein, S B; Simak, V; Simard, O; Simic, Lj; Simion, S; Simmons, B; Simoniello, R; Simonyan, M; Sinervo, P; Sinev, N B; Sipica, V; Siragusa, G; Sircar, A; Sisakyan, A N; Sivoklokov, S Yu; Sjölin, J; Sjursen, T B; Skinnari, L A; Skottowe, H P; Skovpen, K; Skubic, P; Skvorodnev, N; Slater, M; Slavicek, T; Sliwa, K; Sloper, J; Smakhtin, V; Smart, B H; Smirnov, S Yu; Smirnov, Y; Smirnova, L N; Smirnova, O; Smith, B C; Smith, D; Smith, K M; Smizanska, M; Smolek, K; Snesarev, A A; Snow, S W; Snow, J; Snuverink, J; Snyder, S; Soares, M; Sobie, R; Sodomka, J; Soffer, A; Solans, C A; Solar, M; Solc, J; Soldatov, E; Soldevila, U; Solfaroli Camillocci, E; Solodkov, A A; Solovyanov, O V; Soni, N; Sopko, V; Sopko, B; Sosebee, M; Soualah, R; Soukharev, A; Spagnolo, S; Spanò, F; Spighi, R; Spigo, G; Spila, F; Spiwoks, R; Spousta, M; Spreitzer, T; Spurlock, B; St Denis, R D; Stahlman, J; Stamen, R; Stanecka, E; Stanek, R W; Stanescu, C; Stanescu-Bellu, M; Stapnes, S; Starchenko, E A; Stark, J; Staroba, P; Starovoitov, P; Staude, A; Stavina, P; Steele, G; Steinbach, P; Steinberg, P; Stekl, I; Stelzer, B; Stelzer, H J; Stelzer-Chilton, O; Stenzel, H; Stern, S; Stevenson, K; Stewart, G A; Stillings, J A; Stockton, M C; Stoerig, K; Stoicea, G; Stonjek, S; Strachota, P; Stradling, A R; Straessner, A; Strandberg, J; Strandberg, S; Strandlie, A; Strang, M; Strauss, E; Strauss, M; Strizenec, P; Ströhmer, R; Strom, D M; Strong, J A; Stroynowski, R; Strube, J; Stugu, B; Stumer, I; Stupak, J; Sturm, P; Styles, N A; Soh, D A; Su, D; Subramania, Hs; Succurro, A; Sugaya, Y; Sugimoto, T; Suhr, C; Suita, K; Suk, M; Sulin, V V; Sultansoy, S; Sumida, T; Sun, X; Sundermann, J E; Suruliz, K; Sushkov, S; Susinno, G; Sutton, M R; Suzuki, Y; Suzuki, Y; Svatos, M; Sviridov, Yu M; Swedish, S; Sykora, I; Sykora, T; Szeless, B; Sánchez, J; Ta, D; Tackmann, K; Taffard, A; Tafirout, R; Taiblum, N; Takahashi, Y; Takai, H; Takashima, R; Takeda, H; Takeshita, T; Takubo, Y; Talby, M; Talyshev, A; Tamsett, M C; Tanaka, J; Tanaka, R; Tanaka, S; Tanaka, S; Tanaka, Y; Tanasijczuk, A J; Tani, K; Tannoury, N; Tappern, G P; Tapprogge, S; Tardif, D; Tarem, S; Tarrade, F; Tartarelli, G F; Tas, P; Tasevsky, M; Tassi, E; Tatarkhanov, M; Tayalati, Y; Taylor, C; Taylor, F E; Taylor, G N; Taylor, W; Teinturier, M; Teixeira Dias Castanheira, M; Teixeira-Dias, P; Temming, K K; Ten Kate, H; Teng, P K; Terada, S; Terashi, K; Terron, J; Testa, M; Teuscher, R J; Thadome, J; Therhaag, J; Theveneaux-Pelzer, T; Thioye, M; Thoma, S; Thomas, J P; Thompson, E N; Thompson, P D; Thompson, P D; Thompson, A S; Thomsen, L A; Thomson, E; Thomson, M; Thun, R P; Tian, F; Tibbetts, M J; Tic, T; Tikhomirov, V O; Tikhonov, Y A; Timoshenko, S; Tipton, P; Tique Aires Viegas, F J; Tisserant, S; Tobias, J; Toczek, B; Todorov, T; Todorova-Nova, S; Toggerson, B; Tojo, J; Tokár, S; Tokunaga, K; Tokushuku, K; Tollefson, K; Tomoto, M; Tompkins, L; Toms, K; Tong, G; Tonoyan, A; Topfel, C; Topilin, N D; Torchiani, I; Torrence, E; Torres, H; Torró Pastor, E; Toth, J; Touchard, F; Tovey, D R; Trefzger, T; Tremblet, L; Tricoli, A; Trigger, I M; Trincaz-Duvoid, S; Trinh, T N; Tripiana, M F; Trischuk, W; Trivedi, A; Trocmé, B; Troncon, C; Trottier-McDonald, M; Trzebinski, M; Trzupek, A; Tsarouchas, C; Tseng, J C-L; Tsiakiris, M; Tsiareshka, P V; Tsionou, D; Tsipolitis, G; Tsiskaridze, V; Tskhadadze, E G; Tsukerman, I I; Tsulaia, V; Tsung, J-W; Tsuno, S; Tsybychev, D; Tua, A; Tudorache, A; Tudorache, V; Tuggle, J M; Turala, M; Turecek, D; Turk Cakir, I; Turlay, E; Turra, R; Tuts, P M; Tykhonov, A; Tylmad, M; Tyndel, M; Tzanakos, G; Uchida, K; Ueda, I; Ueno, R; Ugland, M; Uhlenbrock, M; Uhrmacher, M; Ukegawa, F; Unal, G; Underwood, D G; Undrus, A; Unel, G; Unno, Y; Urbaniec, D; Usai, G; Uslenghi, M; Vacavant, L; Vacek, V; Vachon, B; Vahsen, S; Valenta, J; Valente, P; Valentinetti, S; Valkar, S; Valladolid Gallego, E; Vallecorsa, S; Valls Ferrer, J A; van der Graaf, H; van der Kraaij, E; Van Der Leeuw, R; van der Poel, E; van der Ster, D; van Eldik, N; van Gemmeren, P; van Kesteren, Z; van Vulpen, I; Vanadia, M; Vandelli, W; Vandoni, G; Vaniachine, A; Vankov, P; Vannucci, F; Varela Rodriguez, F; Vari, R; Varnes, E W; Varol, T; Varouchas, D; Vartapetian, A; Varvell, K E; Vassilakopoulos, V I; Vazeille, F; Vazquez Schroeder, T; Vegni, G; Veillet, J J; Vellidis, C; Veloso, F; Veness, R; Veneziano, S; Ventura, A; Ventura, D; Venturi, M; Venturi, N; Vercesi, V; Verducci, M; Verkerke, W; Vermeulen, J C; Vest, A; Vetterli, M C; Vichou, I; Vickey, T; Vickey Boeriu, O E; Viehhauser, G H A; Viel, S; Villa, M; Villaplana Perez, M; Vilucchi, E; Vincter, M G; Vinek, E; Vinogradov, V B; Virchaux, M; Virzi, J; Vitells, O; Viti, M; Vivarelli, I; Vives Vaque, F; Vlachos, S; Vladoiu, D; Vlasak, M; Vlasov, N; Vogel, A; Vokac, P; Volpi, G; Volpi, M; Volpini, G; von der Schmitt, H; von Loeben, J; von Radziewski, H; von Toerne, E; Vorobel, V; Vorobiev, A P; Vorwerk, V; Vos, M; Voss, R; Voss, T T; Vossebeld, J H; Vranjes, N; Vranjes Milosavljevic, M; Vrba, V; Vreeswijk, M; Vu Anh, T; Vuillermet, R; Vukotic, I; Wagner, W; Wagner, P; Wahlen, H; Wakabayashi, J; Walch, S; Walder, J; Walker, R; Walkowiak, W; Wall, R; Waller, P; Wang, C; Wang, H; Wang, H; Wang, J; Wang, J; Wang, J C; Wang, R; Wang, S M; Warburton, A; Ward, C P; Warsinsky, M; Wasicki, C; Watkins, P M; Watson, A T; Watson, I J; Watson, M F; Watts, G; Watts, S; Waugh, A T; Waugh, B M; Weber, M; Weber, M S; Weber, P; Weidberg, A R; Weigell, P; Weingarten, J; Weiser, C; Wellenstein, H; Wells, P S; Wenaus, T; Wendland, D; Wendler, S; Weng, Z; Wengler, T; Wenig, S; Wermes, N; Werner, M; Werner, P; Werth, M; Wessels, M; Wetter, J; Weydert, C; Whalen, K; Wheeler-Ellis, S J; Whitaker, S P; White, A; White, M J; Whitehead, S R; Whiteson, D; Whittington, D; Wicek, F; Wicke, D; Wickens, F J; Wiedenmann, W; Wielers, M; Wienemann, P; Wiglesworth, C; Wiik, L A M; Wijeratne, P A; Wildauer, A; Wildt, M A; Wilhelm, I; Wilkens, H G; Will, J Z; Williams, E; Williams, H H; Willis, W; Willocq, S; Wilson, J A; Wilson, M G; Wilson, A; Wingerter-Seez, I; Winkelmann, S; Winklmeier, F; Wittgen, M; Wolter, M W; Wolters, H; Wong, W C; Wooden, G; Wosiek, B K; Wotschack, J; Woudstra, M J; Wozniak, K W; Wraight, K; Wright, C; Wright, M; Wrona, B; Wu, S L; Wu, X; Wu, Y; Wulf, E; Wunstorf, R; Wynne, B M; Xella, S; Xiao, M; Xie, S; Xie, Y; Xu, C; Xu, D; Xu, G; Yabsley, B; Yacoob, S; Yamada, M; Yamaguchi, H; Yamamoto, A; Yamamoto, K; Yamamoto, S; Yamamura, T; Yamanaka, T; Yamaoka, J; Yamazaki, T; Yamazaki, Y; Yan, Z; Yang, H; Yang, U K; Yang, Y; Yang, Y; Yang, Z; Yanush, S; Yao, Y; Yasu, Y; Ybeles Smit, G V; Ye, J; Ye, S; Yilmaz, M; Yoosoofmiya, R; Yorita, K; Yoshida, R; Young, C; Youssef, S; Yu, D; Yu, J; Yu, J; Yuan, L; Yurkewicz, A; Zabinski, B; Zaets, V G; Zaidan, R; Zaitsev, A M; Zajacova, Z; Zanello, L; Zaytsev, A; Zeitnitz, C; Zeller, M; Zeman, M; Zemla, A; Zendler, C; Zenin, O; Zeniš, T; Zenonos, Z; Zenz, S; Zerwas, D; Zevi della Porta, G; Zhan, Z; Zhang, D; Zhang, H; Zhang, J; Zhang, X; Zhang, Z; Zhao, L; Zhao, T; Zhao, Z; Zhemchugov, A; Zheng, S; Zhong, J; Zhou, B; Zhou, N; Zhou, Y; Zhu, C G; Zhu, H; Zhu, J; Zhu, Y; Zhuang, X; Zhuravlov, V; Zieminska, D; Zimmermann, R; Zimmermann, S; Zimmermann, S; Ziolkowski, M; Zitoun, R; Zivković, L; Zmouchko, V V; Zobernig, G; Zoccoli, A; Zolnierowski, Y; Zsenei, A; zur Nedden, M; Zutshi, V; Zwalinski, L
2012-03-16
A search for the standard model Higgs boson is performed in the diphoton decay channel. The data used correspond to an integrated luminosity of 4.9 fb(-1) collected with the ATLAS detector at the Large Hadron Collider in proton-proton collisions at a center-of-mass energy of √s=7 TeV. In the diphoton mass range 110-150 GeV, the largest excess with respect to the background-only hypothesis is observed at 126.5 GeV, with a local significance of 2.8 standard deviations. Taking the look-elsewhere effect into account in the range 110-150 GeV, this significance becomes 1.5 standard deviations. The standard model Higgs boson is excluded at 95% confidence level in the mass ranges of 113-115 GeV and 134.5-136 GeV.
Inter-annual and spatial variability of Hamon potential evapotranspiration model coefficients
McCabe, Gregory J.; Hay, Lauren E.; Bock, Andy; Markstrom, Steven L.; Atkinson, R. Dwight
2015-01-01
Monthly calibrated values of the Hamon PET coefficient (C) are determined for 109,951 hydrologic response units (HRUs) across the conterminous United States (U.S.). The calibrated coefficient values are determined by matching calculated mean monthly Hamon PET to mean monthly free-water surface evaporation. For most locations and months the calibrated coefficients are larger than the standard value reported by Hamon. The largest changes in the coefficients were for the late winter/early spring and fall months, whereas the smallest changes were for the summer months. Comparisons of PET computed using the standard value of C and computed using calibrated values of C indicate that for most of the conterminous U.S. PET is underestimated using the standard Hamon PET coefficient, except for the southeastern U.S.
Comparison of Estimation Techniques for the Four Parameter Beta Distribution.
1981-12-01
Gnanadesikan , Pinkham, and Hughes in 1967 (Ref 11). It dealt with the standard beta, and performed the estimation using smallest order statistics. 22 22 The...convergence of the iterative scheme" (Ref 11:611). Beckman and Tietjen picked up on Gnanadesikan , et al., and developed a solution method which is "fast...zia (Second Edition). Reading, Massachusetts: Addison-Wesley Pub- lishing Company, 1978. 11. Gnanadesikan , R., R. S. Pinkham and L. P. Hughes. "Maximum
Distributional properties of relative phase in bimanual coordination.
James, Eric; Layne, Charles S; Newell, Karl M
2010-10-01
Studies of bimanual coordination have typically estimated the stability of coordination patterns through the use of the circular standard deviation of relative phase. The interpretation of this statistic depends upon the assumption of a von Mises distribution. The present study tested this assumption by examining the distributional properties of relative phase in three bimanual coordination patterns. There were significant deviations from the von Mises distribution due to differences in the kurtosis of distributions. The kurtosis depended upon the relative phase pattern performed, with leptokurtic distributions occurring in the in-phase and antiphase patterns and platykurtic distributions occurring in the 30° pattern. Thus, the distributional assumptions needed to validly and reliably use the standard deviation are not necessarily present in relative phase data though they are qualitatively consistent with the landscape properties of the intrinsic dynamics.
Non-specific filtering of beta-distributed data.
Wang, Xinhui; Laird, Peter W; Hinoue, Toshinori; Groshen, Susan; Siegmund, Kimberly D
2014-06-19
Non-specific feature selection is a dimension reduction procedure performed prior to cluster analysis of high dimensional molecular data. Not all measured features are expected to show biological variation, so only the most varying are selected for analysis. In DNA methylation studies, DNA methylation is measured as a proportion, bounded between 0 and 1, with variance a function of the mean. Filtering on standard deviation biases the selection of probes to those with mean values near 0.5. We explore the effect this has on clustering, and develop alternate filter methods that utilize a variance stabilizing transformation for Beta distributed data and do not share this bias. We compared results for 11 different non-specific filters on eight Infinium HumanMethylation data sets, selected to span a variety of biological conditions. We found that for data sets having a small fraction of samples showing abnormal methylation of a subset of normally unmethylated CpGs, a characteristic of the CpG island methylator phenotype in cancer, a novel filter statistic that utilized a variance-stabilizing transformation for Beta distributed data outperformed the common filter of using standard deviation of the DNA methylation proportion, or its log-transformed M-value, in its ability to detect the cancer subtype in a cluster analysis. However, the standard deviation filter always performed among the best for distinguishing subgroups of normal tissue. The novel filter and standard deviation filter tended to favour features in different genome contexts; for the same data set, the novel filter always selected more features from CpG island promoters and the standard deviation filter always selected more features from non-CpG island intergenic regions. Interestingly, despite selecting largely non-overlapping sets of features, the two filters did find sample subsets that overlapped for some real data sets. We found two different filter statistics that tended to prioritize features with different characteristics, each performed well for identifying clusters of cancer and non-cancer tissue, and identifying a cancer CpG island hypermethylation phenotype. Since cluster analysis is for discovery, we would suggest trying both filters on any new data sets, evaluating the overlap of features selected and clusters discovered.
A simple method to relate microwave radiances to upper tropospheric humidity
NASA Astrophysics Data System (ADS)
Buehler, S. A.; John, V. O.
2005-01-01
A brightness temperature (BT) transformation method can be applied to microwave data to retrieve Jacobian weighted upper tropospheric relative humidity (UTH) in a broad layer centered roughly between 6 and 8 km altitude. The UTH bias is below 4% RH, and the relative UTH bias below 20%. The UTH standard deviation is between 2 and 6.5% RH in absolute numbers, or between 10 and 27% in relative numbers. The standard deviation is dominated by the regression noise, resulting from vertical structure not accounted for by the simple transformation relation. The UTH standard deviation due to radiometric noise alone has a relative standard deviation of approximately 7% for a radiometric noise level of 1 K. The retrieval performance was shown to be of almost constant quality for all viewing angles and latitudes, except for problems at high latitudes due to surface effects. A validation of AMSU UTH against radiosonde UTH shows reasonable agreement if known systematic differences between AMSU and radiosonde are taken into account. When the method is applied to supersaturation studies, regression noise and radiometric noise could lead to an apparent supersaturation even if there were no supersaturation. For a radiometer noise level of 1 K the drop-off slope of the apparent supersaturation is 0.17% RH-1, for a noise level of 2 K the slope is 0.12% RH-1. The main conclusion from this study is that the BT transformation method is very well suited for microwave data. Its particular strength is in climatological applications where the simplicity and the a priori independence are key advantages.
Braithwaite, Susan S; Umpierrez, Guillermo E; Chase, J Geoffrey
2013-09-01
Group metrics are described to quantify blood glucose (BG) variability of hospitalized patients. The "multiplicative surrogate standard deviation" (MSSD) is the reverse-transformed group mean of the standard deviations (SDs) of the logarithmically transformed BG data set of each patient. The "geometric group mean" (GGM) is the reverse-transformed group mean of the means of the logarithmically transformed BG data set of each patient. Before reverse transformation is performed, the mean of means and mean of SDs each has its own SD, which becomes a multiplicative standard deviation (MSD) after reverse transformation. Statistical predictions and comparisons of parametric or nonparametric tests remain valid after reverse transformation. A subset of a previously published BG data set of 20 critically ill patients from the first 72 h of treatment under the SPRINT protocol was transformed logarithmically. After rank ordering according to the SD of the logarithmically transformed BG data of each patient, the cohort was divided into two equal groups, those having lower or higher variability. For the entire cohort, the GGM was 106 (÷/× 1.07) mg/dl, and MSSD was 1.24 (÷/× 1.07). For the subgroups having lower and higher variability, respectively, the GGM did not differ, 104 (÷/× 1.07) versus 109 (÷/× 1.07) mg/dl, but the MSSD differed, 1.17 (÷/× 1.03) versus 1.31 (÷/× 1.05), p = .00004. By using the MSSD with its MSD, groups can be characterized and compared according to glycemic variability of individual patient members. © 2013 Diabetes Technology Society.
Başkan, Ceyda; Köz, Özlem G; Duman, Rahmi; Gökçe, Sabite E; Yarangümeli, Ahmet A; Kural, Gülcan
2016-12-01
The purpose of this study is to examine the demographics, clinical properties, and the relation between white-on-white standard automated perimetry (SAP), short wavelength automated perimetry (SWAP), and optical coherence tomographic (OCT) parameters of patients with ocular hypertension. Sixty-one eyes of 61 patients diagnosed with ocular hypertension in the Ankara Numune Education and Research Hospital ophthalmology unit between January 2010 and January 2011 were included in this study. All patients underwent SAP and SWAP tests with the Humphrey visual field analyser using the 30.2 full-threshold test. Retinal nerve fiber layers (RNFL) and optic nerve heads of patients were evaluated with Stratus OCT. Positive correlation was detected between SAP pattern standard deviation value and average intraocular pressure (P=0.017), maximum intraocular pressure (P=0.009), and vertical cup to disc (C/D) ratio (P=0.009). Positive correlation between SWAP median deviation value with inferior (P=0.032), nasal (P=0.005), 6 o'clock quadrant RNFL thickness (P=0.028), and Imax/Tavg ratio (P=0.023) and negative correlation with Smax/Navg ratio (P=0.005) were detected. There was no correlation between central corneal thickness and peripapillary RNFL thicknesses (P>0.05). There was no relation between SAP median deviation, pattern standard deviation values and RNFL thicknesses and optic disc parameters of the OCT. By contrast significant correlation between several SWAP parameters and OCT parameters were detected. SWAP appeared to outperform achromatic SAP when the same 30-2 method was used.
Accuracy of a pulse-coherent acoustic Doppler profiler in a wave-dominated flow
Lacy, J.R.; Sherwood, C.R.
2004-01-01
The accuracy of velocities measured by a pulse-coherent acoustic Doppler profiler (PCADP) in the bottom boundary layer of a wave-dominated inner-shelf environment is evaluated. The downward-looking PCADP measured velocities in eight 10-cm cells at 1 Hz. Velocities measured by the PCADP are compared to those measured by an acoustic Doppler velocimeter for wave orbital velocities up to 95 cm s-1 and currents up to 40 cm s-1. An algorithm for correcting ambiguity errors using the resolution velocities was developed. Instrument bias, measured as the average error in burst mean speed, is -0.4 cm s-1 (standard deviation = 0.8). The accuracy (root-mean-square error) of instantaneous velocities has a mean of 8.6 cm s-1 (standard deviation = 6.5) for eastward velocities (the predominant direction of waves), 6.5 cm s-1 (standard deviation = 4.4) for northward velocities, and 2.4 cm s-1 (standard deviation = 1.6) for vertical velocities. Both burst mean and root-mean-square errors are greater for bursts with ub ??? 50 cm s-1. Profiles of burst mean speeds from the bottom five cells were fit to logarithmic curves: 92% of bursts with mean speed ??? 5 cm s-1 have a correlation coefficient R2 > 0.96. In cells close to the transducer, instantaneous velocities are noisy, burst mean velocities are biased low, and bottom orbital velocities are biased high. With adequate blanking distances for both the profile and resolution velocities, the PCADP provides sufficient accuracy to measure velocities in the bottom boundary layer under moderately energetic inner-shelf conditions.
Distribution Development for STORM Ingestion Input Parameters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fulton, John
The Sandia-developed Transport of Radioactive Materials (STORM) code suite is used as part of the Radioisotope Power System Launch Safety (RPSLS) program to perform statistical modeling of the consequences due to release of radioactive material given a launch accident. As part of this modeling, STORM samples input parameters from probability distributions with some parameters treated as constants. This report described the work done to convert four of these constant inputs (Consumption Rate, Average Crop Yield, Cropland to Landuse Database Ratio, and Crop Uptake Factor) to sampled values. Consumption rate changed from a constant value of 557.68 kg / yr tomore » a normal distribution with a mean of 102.96 kg / yr and a standard deviation of 2.65 kg / yr. Meanwhile, Average Crop Yield changed from a constant value of 3.783 kg edible / m 2 to a normal distribution with a mean of 3.23 kg edible / m 2 and a standard deviation of 0.442 kg edible / m 2 . The Cropland to Landuse Database ratio changed from a constant value of 0.0996 (9.96%) to a normal distribution with a mean value of 0.0312 (3.12%) and a standard deviation of 0.00292 (0.29%). Finally the crop uptake factor changed from a constant value of 6.37e -4 (Bq crop /kg)/(Bq soil /kg) to a lognormal distribution with a geometric mean value of 3.38e -4 (Bq crop /kg)/(Bq soil /kg) and a standard deviation value of 3.33 (Bq crop /kg)/(Bq soil /kg)« less
Water vapor over Europe obtained from remote sensors and compared with a hydrostatic NWP model
NASA Astrophysics Data System (ADS)
Johnsen, K.-P.; Kidder, S. Q.
Due to its high-variability water vapor is a crucial parameter in short-term numerical weather prediction. Integrated water vapor (IWV) data obtained from a network of groundbased Global Positioning System (GPS) receivers mainly over Germany and passive microwave measurements of the Advanced Microwave Sounding Unit (AMSU-A) are compared with the high-resolution regional weather forecast model HRM of the Deutscher Wetterdienst (DWD). Time series of the IWV at 74 GPS stations obtained during the first complete year of the GFZ/GPS network between May 2000 and April 2001 are applied together with colocated forecasts of the HRM model. The low bias (0.08 kg/m 2) between the HRM model and the GPS data can mainly be explained by the bias between the ECMWF analysis data used to initilize the HRM model and the GPS data. The IWV standard deviation between the HRM model and the GPS data during that time is about 2.47 kg/ m2. GPS stations equipped with surface pressure sensors show about 0.29 kg/ m2 lower standard deviation compared with GPS stations with interpolated surface pressure from synoptic stations. The NOAA/NESDIS Total Precipitable Water algorithm is applied to obtain the IWV and to validate the model above the sea. While the mean IWV obtained from the HRM model is about 2.1 kg/ m2 larger than from the AMSU-A data, the standard deviations are 2.46 kg/ m2 (NOAA-15) and 2.29 kg/ m2 (NOAA-16) similar to the IWV standard deviation between HRM and GPS data.
Keratoconus: The ABCD Grading System.
Belin, M W; Duncan, J K
2016-06-01
To propose a new keratoconus classification/staging system that utilises current tomographic data and better reflects the anatomical and functional changes seen in keratoconus. A previously published normative database was reanalysed to generate both anterior and posterior average radii of curvature (ARC and PRC) taken from a 3.0 mm optical zone centred on the thinnest point of the cornea. Mean and standard deviations were recorded and anterior data were compared to the existing Amsler-Krumeich (AK) Classification. ARC, PRC, thinnest pachymetry and distance visual acuity were then used to construct a keratoconus classification. 672 eyes of 336 patients were analysed. Anterior and posterior values were 7.65 ± 0.236 mm and 6.26 ± 0.214 mm, respectively, and thinnest pachymetry values were 534.2 ± 30.36 µm. The ARC values were 2.63, 5.47 and 6.44 standard deviations from the mean values of stages 1-3 in the AK classification, respectively. PRC staging uses the same standard deviation gates. The pachymetric values differed by 4.42 and 7.72 standard deviations for stages 2 and 3, respectively. A new keratoconus staging incorporates anterior and posterior curvature, thinnest pachymetric values, and distance visual acuity and consists of stages 0-4 (5 stages). The proposed system closely matches the existing AK classification stages 1-4 on anterior curvature. As it incorporates posterior curvature and thickness measurements based on the thinnest point, rather than apical measurements, the new staging system better reflects the anatomical changes seen in keratoconus. Georg Thieme Verlag KG Stuttgart · New York.
A log-normal distribution model for the molecular weight of aquatic fulvic acids
Cabaniss, S.E.; Zhou, Q.; Maurice, P.A.; Chin, Y.-P.; Aiken, G.R.
2000-01-01
The molecular weight of humic substances influences their proton and metal binding, organic pollutant partitioning, adsorption onto minerals and activated carbon, and behavior during water treatment. We propose a lognormal model for the molecular weight distribution in aquatic fulvic acids to provide a conceptual framework for studying these size effects. The normal curve mean and standard deviation are readily calculated from measured M(n) and M(w) and vary from 2.7 to 3 for the means and from 0.28 to 0.37 for the standard deviations for typical aquatic fulvic acids. The model is consistent with several types of molecular weight data, including the shapes of high- pressure size-exclusion chromatography (HP-SEC) peaks. Applications of the model to electrostatic interactions, pollutant solubilization, and adsorption are explored in illustrative calculations.The molecular weight of humic substances influences their proton and metal binding, organic pollutant partitioning, adsorption onto minerals and activated carbon, and behavior during water treatment. We propose a log-normal model for the molecular weight distribution in aquatic fulvic acids to provide a conceptual framework for studying these size effects. The normal curve mean and standard deviation are readily calculated from measured Mn and Mw and vary from 2.7 to 3 for the means and from 0.28 to 0.37 for the standard deviations for typical aquatic fulvic acids. The model is consistent with several type's of molecular weight data, including the shapes of high-pressure size-exclusion chromatography (HP-SEC) peaks. Applications of the model to electrostatic interactions, pollutant solubilization, and adsorption are explored in illustrative calculations.
40 CFR 63.4312 - What records must I keep?
Code of Federal Regulations, 2013 CFR
2013-07-01
... (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants: Printing, Coating, and Dyeing of Fabrics and... these records is a deviation from the applicable standard. (a) A copy of each notification and report...
40 CFR 63.4312 - What records must I keep?
Code of Federal Regulations, 2011 CFR
2011-07-01
... (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES National Emission Standards for Hazardous Air Pollutants: Printing, Coating, and Dyeing of Fabrics and Other Textiles... deviation from the applicable standard. (a) A copy of each notification and report that you submitted to...
Verster, Joris C; Roth, Thomas
2011-01-01
This review discusses the methodology of the standardized on-the-road driving test and standard operation procedures to conduct the test and analyze the data. The on-the-road driving test has proven to be a sensitive and reliable method to examine driving ability after administration of central nervous system (CNS) drugs. The test is performed on a public highway in normal traffic. Subjects are instructed to drive with a steady lateral position and constant speed. Its primary parameter, the standard deviation of lateral position (SDLP), ie, an index of ‘weaving’, is a stable measure of driving performance with high test–retest reliability. SDLP differences from placebo are dose-dependent, and do not depend on the subject’s baseline driving skills (placebo SDLP). It is important that standard operation procedures are applied to conduct the test and analyze the data in order to allow comparisons between studies from different sites. PMID:21625472
Verster, Joris C; Roth, Thomas
2011-01-01
This review discusses the methodology of the standardized on-the-road driving test and standard operation procedures to conduct the test and analyze the data. The on-the-road driving test has proven to be a sensitive and reliable method to examine driving ability after administration of central nervous system (CNS) drugs. The test is performed on a public highway in normal traffic. Subjects are instructed to drive with a steady lateral position and constant speed. Its primary parameter, the standard deviation of lateral position (SDLP), ie, an index of 'weaving', is a stable measure of driving performance with high test-retest reliability. SDLP differences from placebo are dose-dependent, and do not depend on the subject's baseline driving skills (placebo SDLP). It is important that standard operation procedures are applied to conduct the test and analyze the data in order to allow comparisons between studies from different sites.
The Effect of Type of Punishment on Resistance to Deviation.
ERIC Educational Resources Information Center
LaVoie, Joseph C.
The comparative effectiveness of an aversive stimulus, withholding of resources, withdrawal of love and reasoning, when used alone and combined with praise, was assessed in the standard laboratory punishment paradigm using 120 first and second graders as subjects. Resistance to deviation was used as the measure of punishment effectiveness. Sex of…
40 CFR 63.9641 - What reports must I submit and when?
Code of Federal Regulations, 2010 CFR
2010-07-01
... provide a statement that there were no deviations from the emission limitations, work practice standards... system was out-of-control during the reporting period. (7) For each deviation from an emission limitation... monitoring system (including a CPMS or COMS) to comply with an emission limitation in this subpart, the...
Jiang, Rongzhong
2007-07-01
An electrochemical cell array was designed that contains a common air electrode and 16 microanodes for high throughput screening of both fuel cells (based on polymer electrolyte membrane) and metal/air batteries (based on liquid electrolyte). Electrode materials can easily be coated on the anodes of the electrochemical cell array and screened by switching a graphite probe from one cell to the others. The electrochemical cell array was used to study direct methanol fuel cells (DMFCs), including high throughput screening of electrode catalysts and determination of optimum operating conditions. For screening of DMFCs, there is about 6% relative standard deviation (percentage of standard deviation versus mean value) for discharge current from 10 to 20 mAcm(2). The electrochemical cell array was also used to study tin/air batteries. The effect of Cu content in the anode electrode on the discharge performance of the tin/air battery was investigated. The relative standard deviations for screening of metal/air battery (based on zinc/air) are 2.4%, 3.6%, and 5.1% for discharge current at 50, 100, and 150 mAcm(2), respectively.
A Spatio-Temporal Approach for Global Validation and Analysis of MODIS Aerosol Products
NASA Technical Reports Server (NTRS)
Ichoku, Charles; Chu, D. Allen; Mattoo, Shana; Kaufman, Yoram J.; Remer, Lorraine A.; Tanre, Didier; Slutsker, Ilya; Holben, Brent N.; Lau, William K. M. (Technical Monitor)
2001-01-01
With the launch of the MODIS sensor on the Terra spacecraft, new data sets of the global distribution and properties of aerosol are being retrieved, and need to be validated and analyzed. A system has been put in place to generate spatial statistics (mean, standard deviation, direction and rate of spatial variation, and spatial correlation coefficient) of the MODIS aerosol parameters over more than 100 validation sites spread around the globe. Corresponding statistics are also computed from temporal subsets of AERONET-derived aerosol data. The means and standard deviations of identical parameters from MOMS and AERONET are compared. Although, their means compare favorably, their standard deviations reveal some influence of surface effects on the MODIS aerosol retrievals over land, especially at low aerosol loading. The direction and rate of spatial variation from MODIS are used to study the spatial distribution of aerosols at various locations either individually or comparatively. This paper introduces the methodology for generating and analyzing the data sets used by the two MODIS aerosol validation papers in this issue.
NASA Astrophysics Data System (ADS)
Kriegerowski, Martin; Rassmann, Katja; Oltrup, Theo; Bende, Thomas; Jean, Benedikt J.
1995-05-01
The refractive outcome of thermokeratoplasty depends upon the location and angle of the coagulation spots, applied with a focusing handpiece onto the corneal surface. Accuracy can be enhanced using a specially designed application mask. An astigmatism correction was performed on 10 human donor eyes (Holmium 25, Technomed, FRG, 15 Hz, 20 mJ/pulse, 25 pulses) with an optical zone of 8.1 mm, 5 eyes received a free hand laser application (marked positions) and the other 5 eyes were treated using a suctioned metal mask with drills for the handpiece (optical zone 8.1 mm). To compare the results a silicone replica was taken and analyzed by a confocal laser microtopometer. The refractive change for the steepest meridian was 10 D with a standard deviation of +/- 3.7 D for the free hand application. Using the application mask the refractive outcome was 9.8 D with a standard deviation of only 0.8 D. Using the application mask the standard deviation for the induced refractive change decreases by a factor of five.
NASA Astrophysics Data System (ADS)
Dong, Min; Dong, Chenghui; Guo, Miao; Wang, Zhe; Mu, Xiaomin
2018-04-01
Multiresolution-based methods, such as wavelet and Contourlet are usually used to image fusion. This work presents a new image fusion frame-work by utilizing area-based standard deviation in dual tree Contourlet trans-form domain. Firstly, the pre-registered source images are decomposed with dual tree Contourlet transform; low-pass and high-pass coefficients are obtained. Then, the low-pass bands are fused with weighted average based on area standard deviation rather than the simple "averaging" rule. While the high-pass bands are merged with the "max-absolute' fusion rule. Finally, the modified low-pass and high-pass coefficients are used to reconstruct the final fused image. The major advantage of the proposed fusion method over conventional fusion is the approximately shift invariance and multidirectional selectivity of dual tree Contourlet transform. The proposed method is compared with wavelet- , Contourletbased methods and other the state-of-the art methods on common used multi focus images. Experiments demonstrate that the proposed fusion framework is feasible and effective, and it performs better in both subjective and objective evaluation.
A standard deviation selection in evolutionary algorithm for grouper fish feed formulation
NASA Astrophysics Data System (ADS)
Cai-Juan, Soong; Ramli, Razamin; Rahman, Rosshairy Abdul
2016-10-01
Malaysia is one of the major producer countries for fishery production due to its location in the equatorial environment. Grouper fish is one of the potential markets in contributing to the income of the country due to its desirable taste, high demand and high price. However, the demand of grouper fish is still insufficient from the wild catch. Therefore, there is a need to farm grouper fish to cater to the market demand. In order to farm grouper fish, there is a need to have prior knowledge of the proper nutrients needed because there is no exact data available. Therefore, in this study, primary data and secondary data are collected even though there is a limitation of related papers and 30 samples are investigated by using standard deviation selection in Evolutionary algorithm. Thus, this study would unlock frontiers for an extensive research in respect of grouper fish feed formulation. Results shown that the fitness of standard deviation selection in evolutionary algorithm is applicable. The feasible and low fitness, quick solution can be obtained. These fitness can be further predicted to minimize cost in farming grouper fish.
Analysis of DGPS/INS and MLS/INS final approach navigation errors and control performance data
NASA Technical Reports Server (NTRS)
Hueschen, Richard M.; Spitzer, Cary R.
1992-01-01
Flight tests were conducted jointly by NASA Langley Research Center and Honeywell, Inc., on a B-737 research aircraft to record a data base for evaluating the performance of a differential DGPS/inertial navigation system (INS) which used GPS Course/Acquisition code receivers. Estimates from the DGPS/INS and a Microwave Landing System (MLS)/INS, and various aircraft parameter data were recorded in real time aboard the aircraft while flying along the final approach path to landing. This paper presents the mean and standard deviation of the DGPS/INS and MLS/INS navigation position errors computed relative to the laser tracker system and of the difference between the DGPS/INS and MLS/INS velocity estimates. RMS errors are presented for DGPS/INS and MLS/INS guidance errors (localizer and glideslope). The mean navigation position errors and standard deviation of the x position coordinate of the DGPS/INS and MLS/INS systems were found to be of similar magnitude while the standard deviation of the y and z position coordinate errors were significantly larger for DGPS/INS compared to MLS/INS.
Performance of digital RGB reflectance color extraction for plaque lesion
NASA Astrophysics Data System (ADS)
Hashim, Hadzli; Taib, Mohd Nasir; Jailani, Rozita; Sulaiman, Saadiah; Baba, Roshidah
2005-01-01
Several clinical psoriasis lesion groups are been studied for digital RGB color features extraction. Previous works have used samples size that included all the outliers lying beyond the standard deviation factors from the peak histograms. This paper described the statistical performances of the RGB model with and without removing these outliers. Plaque lesion is experimented with other types of psoriasis. The statistical tests are compared with respect to three samples size; the original 90 samples, the first size reduction by removing outliers from 2 standard deviation distances (2SD) and the second size reduction by removing outliers from 1 standard deviation distance (1SD). Quantification of data images through the normal/direct and differential of the conventional reflectance method is considered. Results performances are concluded by observing the error plots with 95% confidence interval and findings of the inference T-tests applied. The statistical tests outcomes have shown that B component for conventional differential method can be used to distinctively classify plaque from the other psoriasis groups in consistent with the error plots finding with an improvement in p-value greater than 0.5.
Outcome of facial physiotherapy in patients with prolonged idiopathic facial palsy.
Watson, G J; Glover, S; Allen, S; Irving, R M
2015-04-01
This study investigated whether patients who remain symptomatic more than a year following idiopathic facial paralysis gain benefit from tailored facial physiotherapy. A two-year retrospective review was conducted of all symptomatic patients. Data collected included: age, gender, duration of symptoms, Sunnybrook facial grading system scores pre-treatment and at last visit, and duration of treatment. The study comprised 22 patients (with a mean age of 50.5 years (range, 22-75 years)) who had been symptomatic for more than a year following idiopathic facial paralysis. The mean duration of symptoms was 45 months (range, 12-240 months). The mean duration of follow up was 10.4 months (range, 2-36 months). Prior to treatment, the mean Sunnybrook facial grading system score was 59 (standard deviation = 3.5); this had increased to 83 (standard deviation = 2.7) at the last visit, with an average improvement in score of 23 (standard deviation = 2.9). This increase was significant (p < 0.001). Tailored facial therapy can improve facial grading scores in patients who remain symptomatic for prolonged periods.
Design and preliminary assessment of Vanderbilt hand exoskeleton.
Gasser, Benjamin W; Bennett, Daniel A; Durrough, Christina M; Goldfarb, Michael
2017-07-01
This paper presents the design of a hand exoskeleton intended to enable or facilitate bimanual activities of daily living (ADLs) for individuals with chronic upper extremity hemiparesis resulting from stroke. The paper describes design of the battery-powered, self-contained exoskeleton and presents the results of initial testing with a single subject with hemiparesis from stroke. Specifically, an experiment was conducted requiring the subject to repeatedly remove the lid from a water bottle both with and without the hand exoskeleton. The relative times required to remove the lid from the bottles was considerably lower when using the exoskeleton. Specifically, the average amount of time required to grasp the bottle with the paretic hand without the exoskeleton was 25.9 s, with a standard deviation of 33.5 s, while the corresponding average amount of time required to grasp the bottle with the exoskeleton was 5.1 s, with a standard deviation of 1.9 s. Thus, the task time involving the paretic hand was reduced by a factor of five, while the standard deviation was reduced by a factor of 16.
Evaluation of visual field parameters in patients with chronic obstructive pulmonary disease.
Demir, Helin Deniz; Inönü, Handan; Kurt, Semiha; Doruk, Sibel; Aydın, Erdinc; Etikan, Ilker
2012-08-01
To evaluate the effects of chronic obstructive pulmonary disease (COPD) on retina and optic nerve. Thirty-eight patients with COPD and 29 healthy controls, totally 67 subjects, were included in the study. Visual evoked potentials (VEP) and visual field assessment (both standard achromatic perimetry (SAP) and short-wavelength automated perimetry (SWAP)) were performed on each subject after ophthalmological, neurological and pulmonary examinations. Mean deviation (MD), pattern standard deviation (PSD) and corrected pattern standard deviation (CPSD) were significantly different between patient and control groups as for both SAP and SWAP measurements (p = 0.001, 0.019, 0.009 and p = 0.004,0.019, 0.031, respectively). Short-term fluctuation (SF) was not statistically different between the study and the control groups (p = 0.874 and 0.694, respectively). VEP P100 latencies were significantly different between patients with COPD and the controls (p = 0.019). Chronic obstructive pulmonary disease is a systemic disease, and hypoxia in COPD seems to affect the retina and the optic nerve. © 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.
Gomez, Leah M; Conlee, Kathleen M; Stephens, Martin L
2010-01-01
The National Institutes of Health (NIH) is a major biomedical research-funding body in the United States. Approximately 40% of NIH-funded research involves experimentation on nonhuman animals (Monastersky, 2008). Institutions that conduct animal research with NIH funds must adhere to the Public Health Service (PHS) care and use standards of the Office of Laboratory Animal Welfare (OLAW, 2002a). Institutions deviating significantly from the PHS's animal care and use standards must report these incidents to the NIH's OLAW. This study is an exploratory analysis of all the significant deviations reported by animal-research facilities to OLAW during a 3-month period. The study identifies the most common issues reported and species involved. The study found that the majority of the incidents resulted in animal pain and distress and that 75% ended in animal death. This study offers preliminary recommendations to address the most common problems identified in this analysis. This study urges OLAW and other stakeholders to analyze larger, more recent samples of reported deviations to compare with these results and ultimately improve adherence to animal welfare standards.
Transport property correlations for the niobium-1% zirconium alloy
NASA Astrophysics Data System (ADS)
Senor, David J.; Thomas, J. Kelly; Peddicord, K. L.
1990-10-01
Correlations were developed for the electrical resistivity (ρ), thermal conductivity ( k), and hemispherical total emittance (ɛ) of niobium-1% zirconium as functions of temperature. All three correlations were developed as empirical fits to experimental data. ρ = 5.571 + 4.160 × 10 -2(T) - 4.192 × 10 -6(T) 2 μΩcm , k = 13.16( T) 0.2149W/ mK, ɛ = 6.39 × 10 -2 + 4.98 × 10 -5( T) + 3.62 × 10 -8( T) 2 - 7.28 × 10 -12( T) 3. The relative standard deviation of the electrical resistivity correlation is 1.72% and it is valid over the temperature range 273 to 2700 K. The thermal conductivity correlation has a relative standard deviation of 3.24% and is valid over the temperature range 379 to 1421 K. The hemispherical total emittance correlation was developed for smooth surface materials only and represents a conservative estimate of the emittance of the alloy for space reactor fuel element modeling applications. It has a relative standard deviation of 9.50% and is valid over the temperature range 755 to 2670 K.
Tests for qualitative treatment-by-centre interaction using a 'pushback' procedure.
Ciminera, J L; Heyse, J F; Nguyen, H H; Tukey, J W
1993-06-15
In multicentre clinical trials using a common protocol, the centres are usually regarded as being a fixed factor, thus allowing any treatment-by-centre interaction to be omitted from the error term for the effect of treatment. However, we feel it necessary to use the treatment-by-centre interaction as the error term if there is substantial evidence that the interaction with centres is qualitative instead of quantitative. To make allowance for the estimated uncertainties of the centre means, we propose choosing a reference value (for example, the median of the ordered array of centre means) and converting the individual centre results into standardized deviations from the reference value. The deviations are then reordered, and the results 'pushed back' by amounts appropriate for the corresponding order statistics in a sample from the relevant distribution. The pushed-back standardized deviations are then restored to the original scale. The appearance of opposite signs among the destandardized values for the various centres is then taken as 'substantial evidence' of qualitative interaction. Procedures are presented using, in any combination: (i) Gaussian, or Student's t-distribution; (ii) order-statistic medians or outward 90 per cent points of the corresponding order statistic distributions; (iii) pooling or grouping and pooling the internally estimated standard deviations of the centre means. The use of the least conservative combination--Student's t, outward 90 per cent points, grouping and pooling--is recommended.
Gambling as a teaching aid in the introductory physics laboratory
NASA Astrophysics Data System (ADS)
Horodynski-Matsushigue, L. B.; Pascholati, P. R.; Vanin, V. R.; Dias, J. F.; Yoneama, M.-L.; Siqueira, P. T. D.; Amaku, M.; Duarte, J. L. M.
1998-07-01
Dice throwing is used to illustrate relevant concepts of the statistical theory of uncertainties, in particular the meaning of a limiting distribution, the standard deviation, and the standard deviation of the mean. It is an important part in a sequence of especially programmed laboratory activities, developed for freshmen, at the Institute of Physics of the University of São Paulo. It is shown how this activity is employed within a constructive teaching approach, which aims at a growing understanding of the measuring processes and of the fundamentals of correct statistical handling of experimental data.
NASA Technical Reports Server (NTRS)
Meneghini, Robert; Jones, Jeffrey A.
2010-01-01
We investigate the spatial variability of the normalized radar cross section of the surface (NRCS or Sigma(sup 0)) derived from measurements of the TRMM Precipitation Radar (PR) for the period from 1998 to 2009. The purpose of the study is to understand the way in which the sample standard deviation of the Sigma(sup 0) data changes as a function of spatial resolution, incidence angle, and surface type (land/ocean). The results have implications regarding the accuracy by which the path integrated attenuation from precipitation can be inferred by the use of surface scattering properties.
Scanner K-line photometry of Orion stars
NASA Technical Reports Server (NTRS)
Hesser, J. E.; Mcclintock, W.; Henry, R. C.
1977-01-01
Results are presented for two-channel scanner measurements of calcium K-line strengths in 39 Orion sword and belt stars. Values of the calcium k index and its associated standard error are given for each observed star, and the K-line strengths are compared with those of K-line standard stars and Hyades stars. Plots of k index against reddening-corrected color and of k-index deviation against metal-strength index deviation are provided which show that the Orion sword and belt stars do not differ significantly in their calcium and metal abundances from general field stars.
A passive autofocus system by using standard deviation of the image on a liquid lens
NASA Astrophysics Data System (ADS)
Rasti, Pejman; Kesküla, Arko; Haus, Henry; Schlaak, Helmut F.; Anbarjafari, Gholamreza; Aabloo, Alvo; Kiefer, Rudolf
2015-04-01
Today most of applications have a small camera such as cell phones, tablets and medical devices. A micro lens is required in order to reduce the size of the devices. In this paper an auto focus system is used in order to find the best position of a liquid lens without any active components such as ultrasonic or infrared. In fact a passive auto focus system by using standard deviation of the images on a liquid lens which consist of a Dielectric Elastomer Actuator (DEA) membrane between oil and water is proposed.
NASA Technical Reports Server (NTRS)
Parrish, R. S.; Carter, M. C.
1974-01-01
This analysis utilizes computer simulation and statistical estimation. Realizations of stationary gaussian stochastic processes with selected autocorrelation functions are computer simulated. Analysis of the simulated data revealed that the mean and the variance of a process were functionally dependent upon the autocorrelation parameter and crossing level. Using predicted values for the mean and standard deviation, by the method of moments, the distribution parameters was estimated. Thus, given the autocorrelation parameter, crossing level, mean, and standard deviation of a process, the probability of exceeding the crossing level for a particular length of time was calculated.
Extraction of Coastlines with Fuzzy Approach Using SENTINEL-1 SAR Image
NASA Astrophysics Data System (ADS)
Demir, N.; Kaynarca, M.; Oy, S.
2016-06-01
Coastlines are important features for water resources, sea products, energy resources etc. Coastlines are changed dynamically, thus automated methods are necessary for analysing and detecting the changes along the coastlines. In this study, Sentinel-1 C band SAR image has been used to extract the coastline with fuzzy logic approach. The used SAR image has VH polarisation and 10x10m. spatial resolution, covers 57 sqkm area from the south-east of Puerto-Rico. Additionally, radiometric calibration is applied to reduce atmospheric and orbit error, and speckle filter is used to reduce the noise. Then the image is terrain-corrected using SRTM digital surface model. Classification of SAR image is a challenging task since SAR and optical sensors have very different properties. Even between different bands of the SAR sensors, the images look very different. So, the classification of SAR image is difficult with the traditional unsupervised methods. In this study, a fuzzy approach has been applied to distinguish the coastal pixels than the land surface pixels. The standard deviation and the mean, median values are calculated to use as parameters in fuzzy approach. The Mean-standard-deviation (MS) Large membership function is used because the large amounts of land and ocean pixels dominate the SAR image with large mean and standard deviation values. The pixel values are multiplied with 1000 to easify the calculations. The mean is calculated as 23 and the standard deviation is calculated as 12 for the whole image. The multiplier parameters are selected as a: 0.58, b: 0.05 to maximize the land surface membership. The result is evaluated using airborne LIDAR data, only for the areas where LIDAR dataset is available and secondly manually digitized coastline. The laser points which are below 0,5 m are classified as the ocean points. The 3D alpha-shapes algorithm is used to detect the coastline points from LIDAR data. Minimum distances are calculated between the LIDAR points of coastline with the extracted coastline. The statistics of the distances are calculated as following; the mean is 5.82m, standard deviation is 5.83m and the median value is 4.08 m. Secondly, the extracted coastline is also evaluated with manually created lines on SAR image. Both lines are converted to dense points with 1 m interval. Then the closest distances are calculated between the points from extracted coastline and manually created coastline. The mean is 5.23m, standard deviation is 4.52m. and the median value is 4.13m for the calculated distances. The evaluation values are within the accuracy of used SAR data for both quality assessment approaches.
Global Summary MGS TES Data and Mars-Gram Validation
NASA Technical Reports Server (NTRS)
Justus, C.; Johnson, D.; Parker, Nelson C. (Technical Monitor)
2002-01-01
Mars Global Reference Atmospheric Model (Mars-GRAM 2001) is an engineering-level Mars atmosphere model widely used for many Mars mission applications. From 0-80 km, it is based on NASA Ames Mars General Circulation Model (MGCM), while above 80 km it is based on University of Arizona Mars Thermospheric General Circulation Model. Mars-GRAM 2001 and MGCM use surface topograph$ from Mars Global Surveyor Mars Orbiting Laser Altimeter (MOLA). Validation studies are described comparing Mars-GRAM with a global summary data set of Mars Global Surveyor Thermal Emission Spectrometer (TES) data. TES averages and standard deviations were assembled from binned TES data which covered surface to approx. 40 km, over more than a full Mars year (February, 1999 - June, 2001, just before start of a Mars global dust storm). TES data were binned in 10-by-10 degree latitude-longitude bins (i.e. 36 longitude bins by 19 latitude bins), 12 seasonal bins (based on 30 degree increments of Ls angle). Bin averages and standard deviations were assembled at 23 data levels (temperature at 21 pressure levels, plus surface temperature and surface pressure). Two time-of day bins were used: local time near 2 or 14 hours local time). Two dust optical depth bins wereused: infrared optical depth either less than or greater than 0.25 (which corresponds to visible optical depth either less than or greater than about 0.5). For interests in aerocapture and precision entry and landing, comparisons focused on atmospheric density. TES densities versus height were computed from TES temperature versus pressure, using assumptions of perfect gas law and hydrostatics. Mars-GRAM validation studies used density ratio (TES/Mars-GRAM) evaluated at data bin center points in space and time. Observed average TES/Mars-GRAM density ratios were generally 1+/-0.05, except at high altitudes (15-30 km, depending on season) and high latitudes (> 45 deg N), or at most altitudes in the southern hemisphere at Ls approx. 90 and 180deg). Compared to TES averages for a given latitude and season, TES data had average density standard deviation about the mean of approx. 65-10.5% (varying with height) for all data, or approx. 5-12%, depending on time of day and dust optical depth. Average standard deviation of TES/Mars-GRAM density ratio was 8.9% for local time 2 hours and 7.1% for local time 14 hours. Thus standard deviation of observed TES/Mars-GRAM density ratio, evaluated at matching positions and times, is about the same as the standard deviation of TES data about the TES mean value at a given position and season.
Hendel, Michael D; Bryan, Jason A; Barsoum, Wael K; Rodriguez, Eric J; Brems, John J; Evans, Peter J; Iannotti, Joseph P
2012-12-05
Glenoid component malposition for anatomic shoulder replacement may result in complications. The purpose of this study was to define the efficacy of a new surgical method to place the glenoid component. Thirty-one patients were randomized for glenoid component placement with use of either novel three-dimensional computed tomographic scan planning software combined with patient-specific instrumentation (the glenoid positioning system group), or conventional computed tomographic scan, preoperative planning, and surgical technique, utilizing instruments provided by the implant manufacturer (the standard surgical group). The desired position of the component was determined preoperatively. Postoperatively, a computed tomographic scan was used to define and compare the actual implant location with the preoperative plan. In the standard surgical group, the average preoperative glenoid retroversion was -11.3° (range, -39° to 17°). In the glenoid positioning system group, the average glenoid retroversion was -14.8° (range, -27° to 7°). When the standard surgical group was compared with the glenoid positioning system group, patient-specific instrumentation technology significantly decreased (p < 0.05) the average deviation of implant position for inclination and medial-lateral offset. Overall, the average deviation in version was 6.9° in the standard surgical group and 4.3° in the glenoid positioning system group. The average deviation in inclination was 11.6° in the standard surgical group and 2.9° in the glenoid positioning system group. The greatest benefit of patient-specific instrumentation was observed in patients with retroversion in excess of 16°; the average deviation was 10° in the standard surgical group and 1.2° in the glenoid positioning system group (p < 0.001). Preoperative planning and patient-specific instrumentation use resulted in a significant improvement in the selection and use of the optimal type of implant and a significant reduction in the frequency of malpositioned glenoid implants. Novel three-dimensional preoperative planning, coupled with patient and implant-specific instrumentation, allows the surgeon to better define the preoperative pathology, select the optimal implant design and location, and then accurately execute the plan at the time of surgery.
High-Throughput RNA Interference Screening: Tricks of the Trade
Nebane, N. Miranda; Coric, Tatjana; Whig, Kanupriya; McKellip, Sara; Woods, LaKeisha; Sosa, Melinda; Sheppard, Russell; Rasmussen, Lynn; Bjornsti, Mary-Ann; White, E. Lucile
2016-01-01
The process of validating an assay for high-throughput screening (HTS) involves identifying sources of variability and developing procedures that minimize the variability at each step in the protocol. The goal is to produce a robust and reproducible assay with good metrics. In all good cell-based assays, this means coefficient of variation (CV) values of less than 10% and a signal window of fivefold or greater. HTS assays are usually evaluated using Z′ factor, which incorporates both standard deviation and signal window. A Z′ factor value of 0.5 or higher is acceptable for HTS. We used a standard HTS validation procedure in developing small interfering RNA (siRNA) screening technology at the HTS center at Southern Research. Initially, our assay performance was similar to published screens, with CV values greater than 10% and Z′ factor values of 0.51 ± 0.16 (average ± standard deviation). After optimizing the siRNA assay, we got CV values averaging 7.2% and a robust Z′ factor value of 0.78 ± 0.06 (average ± standard deviation). We present an overview of the problems encountered in developing this whole-genome siRNA screening program at Southern Research and how equipment optimization led to improved data quality. PMID:23616418
Theoretical and experimental prediction of the redox potentials of metallocene compounds
NASA Astrophysics Data System (ADS)
Li, Ya-Ping; Liu, Hai-Bo; Liu, Tao; Yu, Zhang-Yu
2017-11-01
The standard redox electrode potential ( E°) values of metallocene compounds are obtained theoretically with density functional theory (DFT) method at B3LYP/6-311++G( d, p) level and experimentally with cyclic voltammetry (CV). The theoretical E° values of metallocene compounds are in good agreement with experimental ones. We investigate the substituent effects on the redox properties of metallocene compounds. Among the four metallocene compounds, the E° values is largest for titanocene dichloride and smallest for ferrocene.
MUSiC - Model-independent search for deviations from Standard Model predictions in CMS
NASA Astrophysics Data System (ADS)
Pieta, Holger
2010-02-01
We present an approach for a model independent search in CMS. Systematically scanning the data for deviations from the standard model Monte Carlo expectations, such an analysis can help to understand the detector and tune event generators. By minimizing the theoretical bias the analysis is furthermore sensitive to a wide range of models for new physics, including the uncounted number of models not-yet-thought-of. After sorting the events into classes defined by their particle content (leptons, photons, jets and missing transverse energy), a minimally prejudiced scan is performed on a number of distributions. Advanced statistical methods are used to determine the significance of the deviating regions, rigorously taking systematic uncertainties into account. A number of benchmark scenarios, including common models of new physics and possible detector effects, have been used to gauge the power of such a method. )
DOE Office of Scientific and Technical Information (OSTI.GOV)
Magnelli, A; Xia, P
2015-06-15
Purpose: Spine stereotactic body radiotherapy requires very conformal dose distributions and precise delivery. Prior to treatment, a KV cone-beam CT (KV-CBCT) is registered to the planning CT to provide image-guided positional corrections, which depend on selection of the region of interest (ROI) because of imperfect patient positioning and anatomical deformation. Our objective is to determine the dosimetric impact of ROI selections. Methods: Twelve patients were selected for this study with the treatment regions varied from C-spine to T-spine. For each patient, the KV-CBCT was registered to the planning CT three times using distinct ROIs: one encompassing the entire patient, amore » large ROI containing large bony anatomy, and a small target-focused ROI. Each registered CBCT volume, saved as an aligned dataset, was then sent to the planning system. The treated plan was applied to each dataset and dose was recalculated. The tumor dose coverage (percentage of target volume receiving prescription dose), maximum point dose to 0.03 cc of the spinal cord, and dose to 10% of the spinal cord volume (V10) for each alignment were compared to the original plan. Results: The average magnitude of tumor coverage deviation was 3.9%±5.8% with external contour, 1.5%±1.1% with large ROI, 1.3%±1.1% with small ROI. Spinal cord V10 deviation from plan was 6.6%±6.6% with external contour, 3.5%±3.1% with large ROI, and 1.2%±1.0% with small ROI. Spinal cord max point dose deviation from plan was: 12.2%±13.3% with external contour, 8.5%±8.4% with large ROI, and 3.7%±2.8% with small ROI. Conclusion: A small ROI focused on the target results in the smallest deviation from planned dose to target and cord although rotations at large distances from the targets were observed. It is recommended that image fusion during CBCT focus narrowly on the target volume to minimize dosimetric error. Improvement in patient setups may further reduce residual errors.« less
Sedaghat, Ahmad R; Kieff, David A; Bergmark, Regan W; Cunnane, Mary E; Busaba, Nicolas Y
2015-03-01
Performance of septoplasty is dependent on objective evidence of nasal septal deviation. Although physical examination including anterior rhinoscopy and endoscopic examination is the gold standard for evaluation of septal deviation, third-party payors' reviews of septoplasty claims are often made on computed tomography (CT) findings. However, the correlation between radiographic evaluation of septal deviation with physical examination findings is unknown. Retrospective, blinded, independent evaluation of septal deviation in 39 consecutive patients from physical examination, including anterior rhinoscopy and endoscopic examination, by an otolaryngologist and radiographic evaluation of sinus CT scan by a neuroradiologist. Four distinct septal locations (nasal valve, cartilaginous, inferior/maxillary crest and osseous septum) were evaluated on a 4-point scale representing (1) 0% to 25%, (2) >25% to 50%, (3) >50% to 75%, and (4) >75% obstruction. Correlation between physical examination and radiographic evaluations was made by Pearson's correlation and quantitative agreement assessed by Krippendorf's alpha. Statistically significant correlation was detected between physical examination including nasal endoscopy and radiographic assessment of septal deviation only at the osseous septum (p = 0.007, r = 0.425) with low quantitative agreement (α = 0.290). No significant correlation was detected at the cartilaginous septum (p = 0.286, r = 0.175), inferior septum (p = 0.117, r = 0.255), or nasal valve (p = 0.174, r = 0.222). Quantitative agreement at the nasal valve suggested a bias in CT to underestimate physical exam findings (α = -0.490). CT is a poor substitute for physical examination, the gold standard, in assessment of septal deviation. Clinical decisions about pursuit of septoplasty or third-party payors' decisions to approve septoplasty should not be made on radiographic evidence. © 2014 ARS-AAOA, LLC.
9 CFR 439.20 - Criteria for maintaining accreditation.
Code of Federal Regulations, 2011 CFR
2011-01-01
... deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is...) Variability: The absolute value of the standardized difference between the accredited laboratory's result and... constant, is used in place of the absolute value of the standardized difference to determine the CUSUM-V...
9 CFR 439.20 - Criteria for maintaining accreditation.
Code of Federal Regulations, 2013 CFR
2013-01-01
... deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is...) Variability: The absolute value of the standardized difference between the accredited laboratory's result and... constant, is used in place of the absolute value of the standardized difference to determine the CUSUM-V...
9 CFR 439.20 - Criteria for maintaining accreditation.
Code of Federal Regulations, 2012 CFR
2012-01-01
... deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is...) Variability: The absolute value of the standardized difference between the accredited laboratory's result and... constant, is used in place of the absolute value of the standardized difference to determine the CUSUM-V...
9 CFR 439.20 - Criteria for maintaining accreditation.
Code of Federal Regulations, 2014 CFR
2014-01-01
... deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is...) Variability: The absolute value of the standardized difference between the accredited laboratory's result and... constant, is used in place of the absolute value of the standardized difference to determine the CUSUM-V...
9 CFR 439.20 - Criteria for maintaining accreditation.
Code of Federal Regulations, 2010 CFR
2010-01-01
... deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is...) Variability: The absolute value of the standardized difference between the accredited laboratory's result and... constant, is used in place of the absolute value of the standardized difference to determine the CUSUM-V...
[The smallest toy dog from the Roman empire].
Boessneck, J
1989-01-01
This study deals with osseous remains of the smallest breed of dogs found in deposits related to the Roman Imperial period. The bone material has been collected at the Colonia Ulpia Traiana near Xanten on the Rhine. It has been observed that the bones match in size with the smallest breeds of dogs known today.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gould, A.; Yee, J. C.; Pinsonneault, M. H.
The Galactic bulge source MOA-2010-BLG-523S exhibited short-term deviations from a standard microlensing light curve near the peak of an A {sub max} {approx} 265 high-magnification microlensing event. The deviations originally seemed consistent with expectations for a planetary companion to the principal lens. We combine long-term photometric monitoring with a previously published high-resolution spectrum taken near peak to demonstrate that this is an RS CVn variable, so that planetary microlensing is not required to explain the light-curve deviations. This is the first spectroscopically confirmed RS CVn star discovered in the Galactic bulge.
Nozzle geometry for organic vapor jet printing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Forrest, Stephen R.; McGraw, Gregory
A first device is provided. The device includes a print head. The print head further includes a first nozzle hermetically sealed to a first source of gas. The first nozzle has an aperture having a smallest dimension of 0.5 to 500 microns in a direction perpendicular to a flow direction of the first nozzle. At a distance from the aperture into the first nozzle that is 5 times the smallest dimension of the aperture of the first nozzle, the smallest dimension perpendicular to the flow direction is at least twice the smallest dimension of the aperture of the first nozzle.
Nozzle geometry for organic vapor jet printing
Forrest, Stephen R; McGraw, Gregory
2015-01-13
A first device is provided. The device includes a print head. The print head further includes a first nozzle hermetically sealed to a first source of gas. The first nozzle has an aperture having a smallest dimension of 0.5 to 500 microns in a direction perpendicular to a flow direction of the first nozzle. At a distance from the aperture into the first nozzle that is 5 times the smallest dimension of the aperture of the first nozzle, the smallest dimension perpendicular to the flow direction is at least twice the smallest dimension of the aperture of the first nozzle.
Tests of local Lorentz invariance violation of gravity in the standard model extension with pulsars.
Shao, Lijing
2014-03-21
The standard model extension is an effective field theory introducing all possible Lorentz-violating (LV) operators to the standard model and general relativity (GR). In the pure-gravity sector of minimal standard model extension, nine coefficients describe dominant observable deviations from GR. We systematically implemented 27 tests from 13 pulsar systems to tightly constrain eight linear combinations of these coefficients with extensive Monte Carlo simulations. It constitutes the first detailed and systematic test of the pure-gravity sector of minimal standard model extension with the state-of-the-art pulsar observations. No deviation from GR was detected. The limits of LV coefficients are expressed in the canonical Sun-centered celestial-equatorial frame for the convenience of further studies. They are all improved by significant factors of tens to hundreds with existing ones. As a consequence, Einstein's equivalence principle is verified substantially further by pulsar experiments in terms of local Lorentz invariance in gravity.
Silveira, Vladímir de Aquino; Souza, Givago da Silva; Gomes, Bruno Duarte; Rodrigues, Anderson Raiol; Silveira, Luiz Carlos de Lima
2014-01-01
We used psychometric functions to estimate the joint entropy for space discrimination and spatial frequency discrimination. Space discrimination was taken as discrimination of spatial extent. Seven subjects were tested. Gábor functions comprising unidimensionalsinusoidal gratings (0.4, 2, and 10 cpd) and bidimensionalGaussian envelopes (1°) were used as reference stimuli. The experiment comprised the comparison between reference and test stimulithat differed in grating's spatial frequency or envelope's standard deviation. We tested 21 different envelope's standard deviations around the reference standard deviation to study spatial extent discrimination and 19 different grating's spatial frequencies around the reference spatial frequency to study spatial frequency discrimination. Two series of psychometric functions were obtained for 2%, 5%, 10%, and 100% stimulus contrast. The psychometric function data points for spatial extent discrimination or spatial frequency discrimination were fitted with Gaussian functions using the least square method, and the spatial extent and spatial frequency entropies were estimated from the standard deviation of these Gaussian functions. Then, joint entropy was obtained by multiplying the square root of space extent entropy times the spatial frequency entropy. We compared our results to the theoretical minimum for unidimensional Gábor functions, 1/4π or 0.0796. At low and intermediate spatial frequencies and high contrasts, joint entropy reached levels below the theoretical minimum, suggesting non-linear interactions between two or more visual mechanisms. We concluded that non-linear interactions of visual pathways, such as the M and P pathways, could explain joint entropy values below the theoretical minimum at low and intermediate spatial frequencies and high contrasts. These non-linear interactions might be at work at intermediate and high contrasts at all spatial frequencies once there was a substantial decrease in joint entropy for these stimulus conditions when contrast was raised. PMID:24466158
Funkquist, E L; Tuvemo, T; Jonsson, B; Serenius, F; Hedberg-Nyqvist, K
2006-01-01
The effect of protein enrichment of mother's milk on growth of low birthweight infants needs further exploration in order to optimize feeding strategies. The aim of this study was to describe feeding and growth of infants weighing <1,900 g at birth, up to a corrected age of 18 months, with or without protein-enriched breastmilk. A retrospective, descriptive, non-experimental design was used to describe the growth of 52 low birthweight infants. Data on their growth and feeding were collected from medical records at hospitals and child health care clinics. Despite more severe morbidity, the infants given protein-enriched milk showed similar growth as the other study infants. Standard deviation score for length at birth correlated positively with delta standard deviation score for length, from discharge to 12 and from discharge to 18 months corrected age. Duration of 'full' breastfeeding had a significant impact on subsequent improvement in SDS for weight. At discharge a smaller proportion of singletons fed with protein enriched milk were breastfed 'fully'. Infants who established breastfeeding at an early post-menstrual age were born with more optimal weight standard deviation score and had a better weight gain after discharge. We conclude that protein-enriched breast milk enables low birthweight infants requiring especially intensive care to attain growth at discharge comparable to that of healthier infants not given enriched milk. Low standard deviation score for length at birth may predict poor growth after discharge. However duration of 'full' breastfeeding had a significant impact on subsequent improvement in SDS for weight. Therefore it is important that mothers of LBW infants are given sufficient support of lactation and breastfeeding.
Using operations research to plan improvement of the transport of critically ill patients.
Chen, Jing; Awasthi, Anjali; Shechter, Steven; Atkins, Derek; Lemke, Linda; Fisher, Les; Dodek, Peter
2013-01-01
Operations research is the application of mathematical modeling, statistical analysis, and mathematical optimization to understand and improve processes in organizations. The objective of this study was to illustrate how the methods of operations research can be used to identify opportunities to reduce the absolute value and variability of interfacility transport intervals for critically ill patients. After linking data from two patient transport organizations in British Columbia, Canada, for all critical care transports during the calendar year 2006, the steps for transfer of critically ill patients were tabulated into a series of time intervals. Statistical modeling, root-cause analysis, Monte Carlo simulation, and sensitivity analysis were used to test the effect of changes in component intervals on overall duration and variation of transport times. Based on quality improvement principles, we focused on reducing the 75th percentile and standard deviation of these intervals. We analyzed a total of 3808 ground and air transports. Constraining time spent by transport personnel at sending and receiving hospitals was projected to reduce the total time taken by 33 minutes with as much as a 20% reduction in standard deviation of these transport intervals in 75% of ground transfers. Enforcing a policy of requiring acceptance of patients who have life- or limb-threatening conditions or organ failure was projected to reduce the standard deviation of air transport time by 63 minutes and the standard deviation of ground transport time by 68 minutes. Based on findings from our analyses, we developed recommendations for technology renovation, personnel training, system improvement, and policy enforcement. Use of the tools of operations research identifies opportunities for improvement in a complex system of critical care transport.
Wang, Chun; Zheng, Yi; Chang, Hua-Hua
2014-01-01
With the advent of web-based technology, online testing is becoming a mainstream mode in large-scale educational assessments. Most online tests are administered continuously in a testing window, which may post test security problems because examinees who take the test earlier may share information with those who take the test later. Researchers have proposed various statistical indices to assess the test security, and one most often used index is the average test-overlap rate, which was further generalized to the item pooling index (Chang & Zhang, 2002, 2003). These indices, however, are all defined as the means (that is, the expected proportion of common items among examinees) and they were originally proposed for computerized adaptive testing (CAT). Recently, multistage testing (MST) has become a popular alternative to CAT. The unique features of MST make it important to report not only the mean, but also the standard deviation (SD) of test overlap rate, as we advocate in this paper. The standard deviation of test overlap rate adds important information to the test security profile, because for the same mean, a large SD reflects that certain groups of examinees share more common items than other groups. In this study, we analytically derived the lower bounds of the SD under MST, with the results under CAT as a benchmark. It is shown that when the mean overlap rate is the same between MST and CAT, the SD of test overlap tends to be larger in MST. A simulation study was conducted to provide empirical evidence. We also compared the security of MST under the single-pool versus the multiple-pool designs; both analytical and simulation studies show that the non-overlapping multiple-pool design will slightly increase the security risk.
GNSS Antenna Caused Near-Field Interference Effect in Precise Point Positioning Results
NASA Astrophysics Data System (ADS)
Dawidowicz, Karol; Baryła, Radosław
2017-06-01
Results of long-term static GNSS observation processing adjustment prove that the often assumed "averaging multipath effect due to extended observation periods" does not actually apply. It is instead visible a bias that falsifies the coordinate estimation. The comparisons between the height difference measured with a geometrical precise leveling and the height difference provided by GNSS clearly verify the impact of the near-field multipath effect. The aim of this paper is analysis the near-field interference effect with respect to the coordinate domain. We demonstrate that the way of antennas mounting during observation campaign (distance from nearest antennas) can cause visible changes in pseudo-kinematic precise point positioning results. GNSS measured height differences comparison revealed that bias of up to 3 mm can be noticed in Up component when some object (additional GNSS antenna) was placed in radiating near-field region of measuring antenna. Additionally, for both processing scenario (GPS and GPS/GLONASS) the scattering of results clearly increased when additional antenna crosses radiating near-field region of measuring antenna. It is especially true for big choke ring antennas. In short session (15, 30 min.) the standard deviation was about twice bigger in comparison to scenario without additional antenna. When we used typical surveying antennas (short near-field region radius) the effect is almost invisible. In this case it can be observed the standard deviation increase of about 20%. On the other hand we found that surveying antennas are generally characterized by lower accuracy than choke ring antennas. The standard deviation obtained on point with this type of antenna was bigger in all processing scenarios (in comparison to standard deviation obtained on point with choke ring antenna).
Use of airborne and terrestrial lidar to detect ground displacement hazards to water systems
Stewart, J.P.; Hu, Jiawen; Kayen, R.E.; Lembo, A.J.; Collins, B.D.; Davis, C.A.; O'Rourke, T. D.
2009-01-01
We investigate the use of multiepoch airborne and terrestrial lidar to detect and measure ground displacements of sufficient magnitude to damage buried pipelines and other water system facilities that might result, for example, from earthquake or rainfall-induced landslides. Lidar scans are performed at three sites with coincident measurements by total station surveying. Relative horizontal accuracy is evaluated by measurements of lateral dimensions of well defined objects such as buildings and tanks; we find misfits ranging from approximately 5 to 12 cm, which is consistent with previous work. The bias and dispersion of lidar elevation measurements, relative to total station surveying, is assessed at two sites: (1) a power plant site (PP2) with vegetated steeply sloping terrain; and (2) a relatively flat and unvegetated site before and after trenching operations were performed. At PP2, airborne lidar showed minimal elevation bias and a standard deviation of approximately 70 cm, whereas terrestrial lidar did not produce useful results due to beam divergence issues and inadequate sampling of the study region. At the trench site, airborne lidar showed minimal elevation bias and reduced standard deviation relative to PP2 (6-20 cm), whereas terrestrial lidar was nearly unbiased with very low dispersion (4-6 cm). Pre- and posttrench bias-adjusted normalized residuals showed minimal to negligible correlation, but elevation change was affected by relative bias between epochs. The mean of elevation change bias essentially matches the difference in means of pre- and posttrench elevation bias, whereas elevation change standard deviation is sensitive to the dispersion of individual epoch elevations and their correlation coefficient. The observed lidar bias and standard deviations enable reliable detection of damaging ground displacements for some pipelines types (e.g., welded steel) but not all (e.g., concrete with unwelded, mortared joints). ?? ASCE 2009.
Habay, T; Majzoub, S; Perrault, O; Rousseau, C; Pisella, P J
2014-03-01
To assess the functional impact of the severity of dry eye on the quality of vision by measuring an Objective Scatter Index (OSI) using double pass aberrometry. Twenty-eight patients (56 eyes) with dry eye syndromes of varying severity participated in this study. A double-pass aberrometer was used to measure the dynamic changes in the OSI for 20 seconds. The mean and standard deviations of the OSI and the number of blinks occurring during the examination were compared as a function of the clinical severity of dry eye disease. The mean OSI increased with the severity of dry eye syndrome with a significant difference for stages 3 (P<0.01) and 4 (P<0.001) compared to stages 1 and 2, without a significant difference based on age (P>0.8) or visual acuity (P>0.2). Standard deviation of the OSI also increased with the severity of dry eye disease, with a significant difference for stages 3 (P<0.01) and 4 (P<0.0001) compared to stages 1 and 2, with no significant increase in the number of blinks (P>0.2). The values of the OSI standard deviation represented the dynamic nature of aberrometric changes related to the instability of the tear film. Quality of vision of patients deteriorated in relation to the severity of their dry eye. The analysis of OSI standard deviation appears to be an objective way to assess the intensity of subjective visual disturbances reported by patients with dry eye syndrome. It also provides a new tool to assess the severity of damage to the ocular surface. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
NASA Astrophysics Data System (ADS)
Wang, Tao; Zhou, Guoqing; Wang, Jianzhou; Zhou, Lei
2018-03-01
The artificial ground freezing method (AGF) is widely used in civil and mining engineering, and the thermal regime of frozen soil around the freezing pipe affects the safety of design and construction. The thermal parameters can be truly random due to heterogeneity of the soil properties, which lead to the randomness of thermal regime of frozen soil around the freezing pipe. The purpose of this paper is to study the one-dimensional (1D) random thermal regime problem on the basis of a stochastic analysis model and the Monte Carlo (MC) method. Considering the uncertain thermal parameters of frozen soil as random variables, stochastic processes and random fields, the corresponding stochastic thermal regime of frozen soil around a single freezing pipe are obtained and analyzed. Taking the variability of each stochastic parameter into account individually, the influences of each stochastic thermal parameter on stochastic thermal regime are investigated. The results show that the mean temperatures of frozen soil around the single freezing pipe with three analogy method are the same while the standard deviations are different. The distributions of standard deviation have a great difference at different radial coordinate location and the larger standard deviations are mainly at the phase change area. The computed data with random variable method and stochastic process method have a great difference from the measured data while the computed data with random field method well agree with the measured data. Each uncertain thermal parameter has a different effect on the standard deviation of frozen soil temperature around the single freezing pipe. These results can provide a theoretical basis for the design and construction of AGF.
NASA Astrophysics Data System (ADS)
Schwarz-Zanetti, Gabriela; Fäh, Donat; Gache, Sylvain; Kästli, Philipp; Loizeau, Jeanluc; Masciadri, Virgilio; Zenhäusern, Gregor
2018-03-01
The Valais is the most seismically active region of Switzerland. Strong damaging events occurred in 1755, 1855, and 1946. Based on historical documents, we discuss two known damaging events in the sixteenth century: the 1524 Ardon and the 1584 Aigle earthquakes. For the 1524, a document describes damage in Ardon, Plan-Conthey, and Savièse, and a stone tablet at the new bell tower of the Ardon church confirms the reconstruction of the bell tower after the earthquake. Additionally, a significant construction activity in the Upper Valais churches during the second quarter of the sixteenth century is discussed that however cannot be clearly related to this event. The assessed moment magnitude Mw of the 1524 event is 5.8, with an error of about 0.5 units corresponding to one standard deviation. The epicenter is at 46.27 N, 7.27 E with a high uncertainty of about 50 km corresponding to one standard deviation. The assessed moment magnitude Mw of the 1584 main shock is 5.9, with an error of about 0.25 units corresponding to one standard deviation. The epicenter is at 46.33 N and 6.97 E with an uncertainty of about 25 km corresponding to one standard deviation. Exceptional movements in the Lake Geneva wreaked havoc along the shore of the Rhone delta. The large dimension of the induced damage can be explained by an expanded subaquatic slide with resultant tsunami and seiche in Lake Geneva. The strongest of the aftershocks occurred on March 14 with magnitude 5.4 and triggered a destructive landslide covering the villages Corbeyrier and Yvorne, VD.
Silveira, Vladímir de Aquino; Souza, Givago da Silva; Gomes, Bruno Duarte; Rodrigues, Anderson Raiol; Silveira, Luiz Carlos de Lima
2014-01-01
We used psychometric functions to estimate the joint entropy for space discrimination and spatial frequency discrimination. Space discrimination was taken as discrimination of spatial extent. Seven subjects were tested. Gábor functions comprising unidimensionalsinusoidal gratings (0.4, 2, and 10 cpd) and bidimensionalGaussian envelopes (1°) were used as reference stimuli. The experiment comprised the comparison between reference and test stimulithat differed in grating's spatial frequency or envelope's standard deviation. We tested 21 different envelope's standard deviations around the reference standard deviation to study spatial extent discrimination and 19 different grating's spatial frequencies around the reference spatial frequency to study spatial frequency discrimination. Two series of psychometric functions were obtained for 2%, 5%, 10%, and 100% stimulus contrast. The psychometric function data points for spatial extent discrimination or spatial frequency discrimination were fitted with Gaussian functions using the least square method, and the spatial extent and spatial frequency entropies were estimated from the standard deviation of these Gaussian functions. Then, joint entropy was obtained by multiplying the square root of space extent entropy times the spatial frequency entropy. We compared our results to the theoretical minimum for unidimensional Gábor functions, 1/4π or 0.0796. At low and intermediate spatial frequencies and high contrasts, joint entropy reached levels below the theoretical minimum, suggesting non-linear interactions between two or more visual mechanisms. We concluded that non-linear interactions of visual pathways, such as the M and P pathways, could explain joint entropy values below the theoretical minimum at low and intermediate spatial frequencies and high contrasts. These non-linear interactions might be at work at intermediate and high contrasts at all spatial frequencies once there was a substantial decrease in joint entropy for these stimulus conditions when contrast was raised.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, Guangxing; Qian, Yun; Yan, Huiping
One limitation of most global climate models (GCMs) is that with the horizontal resolutions they typically employ, they cannot resolve the subgrid variability (SGV) of clouds and aerosols, adding extra uncertainties to the aerosol radiative forcing estimation. To inform the development of an aerosol subgrid variability parameterization, here we analyze the aerosol SGV over the southern Pacific Ocean simulated by the high-resolution Weather Research and Forecasting model coupled to Chemistry. We find that within a typical GCM grid, the aerosol mass subgrid standard deviation is 15% of the grid-box mean mass near the surface on a 1 month mean basis.more » The fraction can increase to 50% in the free troposphere. The relationships between the sea-salt mass concentration, meteorological variables, and sea-salt emission rate are investigated in both the clear and cloudy portion. Under clear-sky conditions, marine aerosol subgrid standard deviation is highly correlated with the standard deviations of vertical velocity, cloud water mixing ratio, and sea-salt emission rates near the surface. It is also strongly connected to the grid box mean aerosol in the free troposphere (between 2 km and 4 km). In the cloudy area, interstitial sea-salt aerosol mass concentrations are smaller, but higher correlation is found between the subgrid standard deviations of aerosol mass and vertical velocity. Additionally, we find that decreasing the model grid resolution can reduce the marine aerosol SGV but strengthen the correlations between the aerosol SGV and the total water mixing ratio (sum of water vapor, cloud liquid, and cloud ice mixing ratios).« less
The Effect of Upper Limb Massage on Infants' Venipuncture Pain.
Chik, Yuen-Man; Ip, Wan-Yim; Choi, Kai-Chow
2017-02-01
The purpose of the study was to investigate the effect of upper limb massage on relieving pain among infants undergoing venipuncture in Hong Kong. This study was a crossover, double-blind, randomized controlled trial. Eighty infants at the neonatal intensive care unit were randomly assigned to 2 groups in different order to receive interventions. The massage first group (N = 40) received 2-minute massage before venipuncture on the first occasion then received usual care (control) on the second occasion, and vice versa in the massage second group (N = 40). The infants' behavior and physiological responses were recorded on two occasions: (1) right after the intervention and (2) during the first 30 seconds of venipuncture procedure. The mean pain scores (Premature Infant Pain Profile) were significantly lower in infants who received massage (massage first: 6.0 [standard deviation = 3.3]; massage second: 7.30 [standard deviation = 4.4]) versus control (massage first: 12.0 [standard deviation = 4.3]; massage second: 12.7 [standard deviation = 3.1]). The crude and adjusted generalized estimating equations model showed that the infants had significantly lower pain score when receiving massage as compared to receiving the control treatment, and there were no significant time and carryover effects: -6.03 (95% confidence interval: -7.67 to -4.38), p < .001 and -5.96 (95% confidence interval: -7.56 to -4.36), p < .001, respectively. Upper limb massage may be effective in decreasing infants' venipuncture pain perception. Copyright © 2016 American Society for Pain Management Nursing. Published by Elsevier Inc. All rights reserved.
Comparison of Predictive Modeling Methods of Aircraft Landing Speed
NASA Technical Reports Server (NTRS)
Diallo, Ousmane H.
2012-01-01
Expected increases in air traffic demand have stimulated the development of air traffic control tools intended to assist the air traffic controller in accurately and precisely spacing aircraft landing at congested airports. Such tools will require an accurate landing-speed prediction to increase throughput while decreasing necessary controller interventions for avoiding separation violations. There are many practical challenges to developing an accurate landing-speed model that has acceptable prediction errors. This paper discusses the development of a near-term implementation, using readily available information, to estimate/model final approach speed from the top of the descent phase of flight to the landing runway. As a first approach, all variables found to contribute directly to the landing-speed prediction model are used to build a multi-regression technique of the response surface equation (RSE). Data obtained from operations of a major airlines for a passenger transport aircraft type to the Dallas/Fort Worth International Airport are used to predict the landing speed. The approach was promising because it decreased the standard deviation of the landing-speed error prediction by at least 18% from the standard deviation of the baseline error, depending on the gust condition at the airport. However, when the number of variables is reduced to the most likely obtainable at other major airports, the RSE model shows little improvement over the existing methods. Consequently, a neural network that relies on a nonlinear regression technique is utilized as an alternative modeling approach. For the reduced number of variables cases, the standard deviation of the neural network models errors represent over 5% reduction compared to the RSE model errors, and at least 10% reduction over the baseline predicted landing-speed error standard deviation. Overall, the constructed models predict the landing-speed more accurately and precisely than the current state-of-the-art.
Comparison of polyurethane with cyanoacrylate in hemostasis of vascular injury in guinea pigs.
Kubrusly, Luiz Fernando; Formighieri, Marina Simões; Lago, José Vitor Martins; Graça, Yorgos Luiz Santos de Salles; Sobral, Ana Cristina Lira; Lago, Marianna Martins
2015-01-01
To evaluate the behavior of castor oil-derived polyurethane as a hemostatic agent and tissue response after abdominal aortic injury and to compare it with 2-octyl-cyanoacrylate. Twenty-four Guinea Pigs were randomly divided into three groups of eight animals (I, II, and III). The infrarenal abdominal aorta was dissected, clamped proximally and distally to the vascular puncture site. In group I (control), hemostasis was achieved with digital pressure; in group II (polyurethane) castor oil-derived polyurethane was applied, and in group III (cyanoacrylate), 2-octyl-cyanoacrylate was used. Group II was subdivided into IIA and IIB according to the time of preparation of the hemostatic agent. Mean blood loss in groups IIA, IIB and III was 0.002 grams (g), 0.008 g, and 0.170 g, with standard deviation of 0.005 g, 0.005 g, and 0.424 g, respectively (P=0.069). The drying time for cyanoacrylate averaged 81.5 seconds (s) (standard deviation: 51.5 seconds) and 126.1 s (standard deviation: 23.0 s) for polyurethane B (P=0.046). However, there was a trend (P=0.069) for cyanoacrylate to dry more slowly than polyurethane A (mean: 40.5 s; SD: 8.6 s). Furthermore, polyurethane A had a shorter drying time than polyurethane B (P=0.003), mean IIA of 40.5 s (standard deviation: 8.6 s). In group III, 100% of the animals had mild/severe fibrosis, while in group II only 12.5% showed this degree of fibrosis (P=0.001). Polyurethane derived from castor oil showed similar hemostatic behavior to octyl-2-cyanoacrylate. There was less perivascular tissue response with polyurethane when compared with cyanoacrylate.
Schneider, Harald Jörn; Saller, Bernhard; Klotsche, Jens; März, Winfried; Erwa, Wolfgang; Wittchen, Hans-Ullrich; Stalla, Günter Karl
2006-05-01
Insulin-like growth factor-I (IGF-I) has been suggested to be a prognostic marker for the development of cancer and, more recently, cardiovascular disease. These diseases are closely linked to obesity, but reports of the association of IGF-I with measures of obesity are divergent. In this study, we assessed the association of age-dependent IGF-I standard deviation scores with body mass index (BMI) and intra-abdominal fat accumulation in a large population. A cross-sectional, epidemiological study. IGF-I levels were measured with an automated chemiluminescence assay system in 6282 patients from the DETECT study. Weight, height, and waist and hip circumference were measured according to the written instructions. Standard deviation scores (SDS), correcting IGF-I levels for age, were calculated and were used for further analyses. An inverse U-shaped association of IGF-I SDS with BMI, waist circumference, and the ratio of waist circumference to height was found. BMI was positively associated with IGF-I SDS in normal weight subjects, and negatively associated in obese subjects. The highest mean IGF-I SDS were seen at a BMI of 22.5-25 kg/m2 in men (+0.08), and at a BMI of 27.5-30 kg/m2 in women (+0.21). Multiple linear regression models, controlling for different diseases, medications and risk conditions, revealed a significant negative association of BMI with IGF-I SDS. BMI contributed most to the additional explained variance to the other health conditions. IGF-I standard deviation scores are decreased in obesity and underweight subjects. These interactions should be taken into account when analyzing the association of IGF-I with diseases and risk conditions.
Feng, L; Hua, C; Sun, H; Qin, L-Y; Niu, P-P; Guo, Z-N; Yang, Y
2018-01-01
To investigate the association between serum uric acid level and the presence and progression of carotid atherosclerosis in Chinese individuals aged 75 years or older. Case-control study. In a teaching hospital. Five hundred and sixty-four elderlies (75 years or above) who underwent general health screening in our hospital were enrolled. The detailed carotid ultrasound results, physical examination information, medical history, and laboratory test results including serum uric acid level were recorded, these data were used to analyze the relationship between serum uric acid level and carotid atherosclerosis. Then, subjects who underwent the second carotid ultrasound 1.5-2 years later were further identified to analyzed the relationship between serum uric acid and the progression of carotid atherosclerosis. A total of 564 subjects were included, carotid plaque was found in 482 (85.5%) individuals. Logistic regression showed that subjects with elevated serum uric acid (expressed per 1 standard deviation change) had significantly higher incidence of carotid plaque (odds ratio, 1.37; 95% confidence interval, 1.07-1.75; P= 0.012) after controlling for other factors. A total of 236 subjects underwent the follow-up carotid ultrasound. Linear regression showed that serum uric acid level (expressed per 1 standard deviation change; 1 standard deviation = 95.5 μmol/L) was significantly associated with percentage of change of plaque score (P = 0.008). Multivariable linear regression showed that 1 standard deviation increase in serum uric acid levels was expected to increase 0.448% of plaque score (P = 0.023). The elevated serum uric acid level may be independently and significantly associated with the presence and progression of carotid atherosclerosis in Chinese individuals aged 75 years or older.
NASA Astrophysics Data System (ADS)
Azim Khairi, M.; Rahman, Mohamed Abd
2018-01-01
Many academic articles were published in Malaysia promoting the goodness of lean in manufacturing and industrial sectors but less attention was apparently given to the possibility of obtaining the same universal benefits when applying lean in non-manufacturing sectors especially higher education. This study aims to determine the level of lean awareness among a local university’s community taking its Faculty of Engineering (FoE) as the case study. It also seeks to identify typical FoE’s staff perception on lean regarding its benefits and the obstacles in implementing it. A web-based survey using questionnaires was carried out for 215 respondents consisting of academic and administrative staff of the faculty. Statistical Package for the Social Science (SPSS) was used to analyze the survey data collected. A total of 13.95% of respondents returned the forms. Slightly more than half of those responded (56.7%) have encountered some of the lean terms with mean 1.43 and standard deviation 0.504. However, the large amount of standard deviation somewhat indicates that the real level of lean awareness of FoE as a group was low. In terms of lean benefits, reduction of waste was favored (93.3%) by the respondents with mean 0.93 and standard deviation 0.254. For obstacles in implementing lean, lack of knowledge was selected by most respondents (86.7%) to be the major factor with mean 0.87 and standard deviation 0.346. Through the analysis done, the study may conclude that level of lean awareness among the university‘s community was low thus may hinder implementation of lean concept.
Comparison of polyurethane with cyanoacrylate in hemostasis of vascular injury in guinea pigs
Kubrusly, Luiz Fernando; Formighieri, Marina Simões; Lago, José Vitor Martins; Graça, Yorgos Luiz Santos de Salles; Sobral, Ana Cristina Lira; Lago, Marianna Martins
2015-01-01
Objective To evaluate the behavior of castor oil-derived polyurethane as a hemostatic agent and tissue response after abdominal aortic injury and to compare it with 2-octyl-cyanoacrylate. Methods Twenty-four Guinea Pigs were randomly divided into three groups of eight animals (I, II, and III). The infrarenal abdominal aorta was dissected, clamped proximally and distally to the vascular puncture site. In group I (control), hemostasis was achieved with digital pressure; in group II (polyurethane) castor oil-derived polyurethane was applied, and in group III (cyanoacrylate), 2-octyl-cyanoacrylate was used. Group II was subdivided into IIA and IIB according to the time of preparation of the hemostatic agent. Results Mean blood loss in groups IIA, IIB and III was 0.002 grams (g), 0.008 g, and 0.170 g, with standard deviation of 0.005 g, 0.005 g, and 0.424 g, respectively (P=0.069). The drying time for cyanoacrylate averaged 81.5 seconds (s) (standard deviation: 51.5 seconds) and 126.1 s (standard deviation: 23.0 s) for polyurethane B (P=0.046). However, there was a trend (P=0.069) for cyanoacrylate to dry more slowly than polyurethane A (mean: 40.5 s; SD: 8.6 s). Furthermore, polyurethane A had a shorter drying time than polyurethane B (P=0.003), mean IIA of 40.5 s (standard deviation: 8.6 s). In group III, 100% of the animals had mild/severe fibrosis, while in group II only 12.5% showed this degree of fibrosis (P=0.001). Conclusion Polyurethane derived from castor oil showed similar hemostatic behavior to octyl-2-cyanoacrylate. There was less perivascular tissue response with polyurethane when compared with cyanoacrylate. PMID:25859876
NASA Astrophysics Data System (ADS)
Krishna Sarkar, Ram; Medhekar, S.
2007-12-01
In this paper, we have investigated the propagation behavior of a Gaussian beam in cubic quintic nonlinear medium with and without absorption or gain. A governing differential equation for the evolution of beam width with the distance of propagation has been derived using the standard parabolic equation approach. By solving the governing equation numerically for different sets of parameters, we have shown that spatial solitons of fixed width and desired intensity and of fixed intensity and desired width are possible. Such liberty does not exist in other saturable media. We have also investigated self-tapering and self-uptapering of spatial solitons in the presence of absorption or gain and showed that the rate of self-tapering/uptapering is not only controlled by the magnitude of absorption or gain but also by the values of cubic and quintic terms. It is revealed that by self-tapering, the smallest achievable soliton width decreases/increases by increasing the magnitude of the cubic/quintic term. It is also revealed that the smallest achievable soliton width by self-tapering, is smaller for a larger initial width.
Protocol deviations before and after IV tPA in community hospitals
Adelman, Eric E.; Scott, Phillip A.; Skolarus, Lesli E.; Fox, Allison K.; Frederiksen, Shirley M.; Meurer, William J.
2015-01-01
Background Protocol deviations before and after tPA treatment for ischemic stroke are common. It is unclear if patient or hospital factors predict protocol deviations. We examined predictors of protocol deviations and the effects of protocol violations on symptomatic intracerebral hemorrhage. Methods We used data from the INSTINCT trial, a cluster-randomized, controlled trial evaluating the efficacy of a barrier assessment and educational intervention to increase appropriate tPA use in 24 Michigan community hospitals, to review tPA treatments between 2007 and 2010. Protocol violations were defined as deviations from the standard tPA protocol, both before and after treatment. Multi-level logistic regression models were fitted to determine if patient and hospital variables were associated with pre-treatment or post-treatment protocol deviations. Results During the study, 557 patients (mean age 70; 52% male; median NIHSS 12) were treated with tPA. Protocol deviations occurred in 233 (42%) patients: 16% had pre-treatment deviations, 35% had post-treatment deviations, and 9% had both. The most common protocol deviations included elevated post-treatment blood pressure, antithrombotic agent use within 24 hours of treatment, and elevated pre-treatment blood pressure. Protocol deviations were not associated with symptomatic intracerebral hemorrhage, stroke severity, or hospital factors. Older age was associated with pre-treatment protocol deviations (adjusted OR 0.52; 95% confidence interval 0.30-0.92). Pre-treatment deviations were associated with post-treatment deviations (adjusted OR 3.20; 95% confidence interval 1.91-5.35). Conclusions Protocol deviations were not associated with symptomatic intracerebral hemorrhage. Aside from age, patient and hospital factors were not associated with protocol deviations. PMID:26419527
Belghith, Akram; Bowd, Christopher; Medeiros, Felipe A; Hammel, Naama; Yang, Zhiyong; Weinreb, Robert N; Zangwill, Linda M
2016-02-01
We determined if the Bruch's membrane opening (BMO) location changes over time in healthy eyes and eyes with progressing glaucoma, and validated an automated segmentation algorithm for identifying the BMO in Cirrus high-definition coherence tomography (HD-OCT) images. We followed 95 eyes (35 progressing glaucoma and 60 healthy) for an average of 3.7 ± 1.1 years. A stable group of 50 eyes had repeated tests over a short period. In each B-scan of the stable group, the BMO points were delineated manually and automatically to assess the reproducibility of both segmentation methods. Moreover, the BMO location variation over time was assessed longitudinally on the aligned images in 3D space point by point in x, y, and z directions. Mean visual field mean deviation at baseline of the progressing glaucoma group was -7.7 dB. Mixed-effects models revealed small nonsignificant changes in BMO location over time for all directions in healthy eyes (the smallest P value was 0.39) and in the progressing glaucoma eyes (the smallest P value was 0.30). In the stable group, the overall intervisit-intraclass correlation coefficient (ICC) and coefficient of variation (CV) were 98.4% and 2.1%, respectively, for the manual segmentation and 98.1% and 1.9%, respectively, for the automated algorithm. Bruch's membrane opening location was stable in normal and progressing glaucoma eyes with follow-up between 3 and 4 years indicating that it can be used as reference point in monitoring glaucoma progression. The BMO location estimation with Cirrus HD-OCT using manual and automated segmentation showed excellent reproducibility.
NASA Astrophysics Data System (ADS)
Barrett, S. A.; Prieto, G. A.; Beroza, G. C.
2015-12-01
There is strong evidence that metamorphic reactions play a role in enabling the rupture of intermediate-depth earthquakes; however, recent studies of the Bucaramanga Nest at a depth of 135-165 km under Colombia indicate that intermediate-depth seismicity shows low radiation efficiency and strong scaling of stress drop with slip/size, which suggests a dramatic weakening process, as proposed in the thermal shear instability model. Decreasing stress drop with slip and low seismic efficiency could have a measurable effect on the magnitude-frequency distribution of small earthquakes by causing them to become undetectable at substantially larger seismic moment than would be the case if stress drop were constant. We explore the population of small earthquakes in the Bucaramanga Nest using an empirical subspace detector to push the detection limit to lower magnitude. Using this approach, we find ~30,000 small, previously uncatalogued earthquakes during a 6-month period in 2013. We calculate magnitudes for these events using their relative amplitudes. Despite the additional detections, we observe a sharp deviation from a Gutenberg-Richter magnitude frequency distribution with a marked deficiency of events at the smallest magnitudes. This scarcity of small earthquakes is not easily ascribed to the detectability threshold; tests of our ability to recover small-magnitude waveforms of Bucaramanga Nest earthquakes in the continuous data indicate that we should be able to detect events reliably at magnitudes that are nearly a full magnitude unit smaller than the smallest earthquakes we observe. The implication is that nearly 100,000 events expected for a Gutenberg-Richter MFD are "missing," and that this scarcity of small earthquakes may provide new support for the thermal runaway mechanism in intermediate-depth earthquake mechanics.
Verification of calculated skin doses in postmastectomy helical tomotherapy.
Ito, Shima; Parker, Brent C; Levine, Renee; Sanders, Mary Ella; Fontenot, Jonas; Gibbons, John; Hogstrom, Kenneth
2011-10-01
To verify the accuracy of calculated skin doses in helical tomotherapy for postmastectomy radiation therapy (PMRT). In vivo thermoluminescent dosimeters (TLDs) were used to measure the skin dose at multiple points in each of 14 patients throughout the course of treatment on a TomoTherapy Hi·Art II system, for a total of 420 TLD measurements. Five patients were evaluated near the location of the mastectomy scar, whereas 9 patients were evaluated throughout the treatment volume. The measured dose at each location was compared with calculations from the treatment planning system. The mean difference and standard error of the mean difference between measurement and calculation for the scar measurements was -1.8% ± 0.2% (standard deviation [SD], 4.3%; range, -11.1% to 10.6%). The mean difference and standard error of the mean difference between measurement and calculation for measurements throughout the treatment volume was -3.0% ± 0.4% (SD, 4.7%; range, -18.4% to 12.6%). The mean difference and standard error of the mean difference between measurement and calculation for all measurements was -2.1% ± 0.2% (standard deviation, 4.5%: range, -18.4% to 12.6%). The mean difference between measured and calculated TLD doses was statistically significant at two standard deviations of the mean, but was not clinically significant (i.e., was <5%). However, 23% of the measured TLD doses differed from the calculated TLD doses by more than 5%. The mean of the measured TLD doses agreed with TomoTherapy calculated TLD doses within our clinical criterion of 5%. Copyright © 2011 Elsevier Inc. All rights reserved.
Verification of Calculated Skin Doses in Postmastectomy Helical Tomotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ito, Shima; Parker, Brent C., E-mail: bcparker@marybird.com; Mary Bird Perkins Cancer Center, Baton Rouge, LA
2011-10-01
Purpose: To verify the accuracy of calculated skin doses in helical tomotherapy for postmastectomy radiation therapy (PMRT). Methods and Materials: In vivo thermoluminescent dosimeters (TLDs) were used to measure the skin dose at multiple points in each of 14 patients throughout the course of treatment on a TomoTherapy Hi.Art II system, for a total of 420 TLD measurements. Five patients were evaluated near the location of the mastectomy scar, whereas 9 patients were evaluated throughout the treatment volume. The measured dose at each location was compared with calculations from the treatment planning system. Results: The mean difference and standard errormore » of the mean difference between measurement and calculation for the scar measurements was -1.8% {+-} 0.2% (standard deviation [SD], 4.3%; range, -11.1% to 10.6%). The mean difference and standard error of the mean difference between measurement and calculation for measurements throughout the treatment volume was -3.0% {+-} 0.4% (SD, 4.7%; range, -18.4% to 12.6%). The mean difference and standard error of the mean difference between measurement and calculation for all measurements was -2.1% {+-} 0.2% (standard deviation, 4.5%: range, -18.4% to 12.6%). The mean difference between measured and calculated TLD doses was statistically significant at two standard deviations of the mean, but was not clinically significant (i.e., was <5%). However, 23% of the measured TLD doses differed from the calculated TLD doses by more than 5%. Conclusions: The mean of the measured TLD doses agreed with TomoTherapy calculated TLD doses within our clinical criterion of 5%.« less
NASA Astrophysics Data System (ADS)
Profe, Jörn; Ohlendorf, Christian
2017-04-01
XRF-scanning is the state-of-the-art technique for geochemical analyses in marine and lacustrine sedimentology for more than a decade. However, little attention has been paid to data precision and technical limitations so far. Using homogenized, dried and powdered samples (certified geochemical reference standards and samples from a lithologically-contrasting loess-paleosol sequence) minimizes many adverse effects that influence the XRF-signal when analyzing wet sediment cores. This allows the investigation of data precision under ideal conditions and documents a new application of the XRF core-scanner technology at the same time. Reliable interpretations of XRF results require data precision evaluation of single elements as a function of X-ray tube, measurement time, sample compaction and quality of peak fitting. Ten-fold measurement of each sample constitutes data precision. Data precision of XRF measurements theoretically obeys Poisson statistics. Fe and Ca exhibit largest deviations from Poisson statistics. The same elements show the least mean relative standard deviations in the range from 0.5% to 1%. This represents the technical limit of data precision achievable by the installed detector. Measurement times ≥ 30 s reveal mean relative standard deviations below 4% for most elements. The quality of peak fitting is only relevant for elements with overlapping fluorescence lines such as Ba, Ti and Mn or for elements with low concentrations such as Y, for example. Differences in sample compaction are marginal and do not change mean relative standard deviation considerably. Data precision is in the range reported for geochemical reference standards measured by conventional techniques. Therefore, XRF scanning of discrete samples provide a cost- and time-efficient alternative to conventional multi-element analyses. As best trade-off between economical operation and data quality, we recommend a measurement time of 30 s resulting in a total scan time of 30 minutes for 30 samples.
Schulze, Walther H. W.; Jiang, Yuan; Wilhelms, Mathias; Luik, Armin; Dössel, Olaf; Seemann, Gunnar
2015-01-01
In case of chest pain, immediate diagnosis of myocardial ischemia is required to respond with an appropriate treatment. The diagnostic capability of the electrocardiogram (ECG), however, is strongly limited for ischemic events that do not lead to ST elevation. This computational study investigates the potential of different electrode setups in detecting early ischemia at 10 minutes after onset: standard 3-channel and 12-lead ECG as well as body surface potential maps (BSPMs). Further, it was assessed if an additional ECG electrode with optimized position or the right-sided Wilson leads can improve sensitivity of the standard 12-lead ECG. To this end, a simulation study was performed for 765 different locations and sizes of ischemia in the left ventricle. Improvements by adding a single, subject specifically optimized electrode were similar to those of the BSPM: 2–11% increased detection rate depending on the desired specificity. Adding right-sided Wilson leads had negligible effect. Absence of ST deviation could not be related to specific locations of the ischemic region or its transmurality. As alternative to the ST time integral as a feature of ST deviation, the K point deviation was introduced: the baseline deviation at the minimum of the ST-segment envelope signal, which increased 12-lead detection rate by 7% for a reasonable threshold. PMID:26587538
Loewe, Axel; Schulze, Walther H W; Jiang, Yuan; Wilhelms, Mathias; Luik, Armin; Dössel, Olaf; Seemann, Gunnar
2015-01-01
In case of chest pain, immediate diagnosis of myocardial ischemia is required to respond with an appropriate treatment. The diagnostic capability of the electrocardiogram (ECG), however, is strongly limited for ischemic events that do not lead to ST elevation. This computational study investigates the potential of different electrode setups in detecting early ischemia at 10 minutes after onset: standard 3-channel and 12-lead ECG as well as body surface potential maps (BSPMs). Further, it was assessed if an additional ECG electrode with optimized position or the right-sided Wilson leads can improve sensitivity of the standard 12-lead ECG. To this end, a simulation study was performed for 765 different locations and sizes of ischemia in the left ventricle. Improvements by adding a single, subject specifically optimized electrode were similar to those of the BSPM: 2-11% increased detection rate depending on the desired specificity. Adding right-sided Wilson leads had negligible effect. Absence of ST deviation could not be related to specific locations of the ischemic region or its transmurality. As alternative to the ST time integral as a feature of ST deviation, the K point deviation was introduced: the baseline deviation at the minimum of the ST-segment envelope signal, which increased 12-lead detection rate by 7% for a reasonable threshold.