A Dedicated Computational Platform for Cellular Monte Carlo T-CAD Software Tools
2015-07-14
computer that establishes an encrypted Virtual Private Network ( OpenVPN [44]) based on the Secure Socket Layer (SSL) paradigm. Each user is given a...security certificate for each device used to connect to the computing nodes. Stable OpenVPN clients are available for Linux, Microsoft Windows, Apple OSX...platform is granted by an encrypted connection base on the Secure Socket Layer (SSL) protocol, and implemented in the OpenVPN Virtual Personal Network
Authentication Binding between SSL/TLS and HTTP
NASA Astrophysics Data System (ADS)
Saito, Takamichi; Sekiguchi, Kiyomi; Hatsugai, Ryosuke
While the Secure Socket Layer or Transport Layer Security (SSL/TLS) is assumed to provide secure communications over the Internet, many web applications utilize basic or digest authentication of Hyper Text Transport Protocol (HTTP) over SSL/TLS. Namely, in the scheme, there are two different authentication schemes in a session. Since they are separated by a layer, these are not convenient for a web application. Moreover, the scheme may also cause problems in establishing secure communication. Then we provide a scheme of authentication binding between SSL/TLS and HTTP without modifying SSL/TLS protocols and its implementation, and we show the effectiveness of our proposed scheme.
NASA Technical Reports Server (NTRS)
Powell, John D.
2003-01-01
This document discusses the verification of the Secure Socket Layer (SSL) communication protocol as a demonstration of the Model Based Verification (MBV) portion of the verification instrument set being developed under the Reducing Software Security Risk (RSSR) Trough an Integrated Approach research initiative. Code Q of the National Aeronautics and Space Administration (NASA) funds this project. The NASA Goddard Independent Verification and Validation (IV&V) facility manages this research program at the NASA agency level and the Assurance Technology Program Office (ATPO) manages the research locally at the Jet Propulsion Laboratory (California institute of Technology) where the research is being carried out.
SSL - THE SIMPLE SOCKETS LIBRARY
NASA Technical Reports Server (NTRS)
Campbell, C. E.
1994-01-01
The Simple Sockets Library (SSL) allows C programmers to develop systems of cooperating programs using Berkeley streaming Sockets running under the TCP/IP protocol over Ethernet. The SSL provides a simple way to move information between programs running on the same or different machines and does so with little overhead. The SSL can create three types of Sockets: namely a server, a client, and an accept Socket. The SSL's Sockets are designed to be used in a fashion reminiscent of the use of FILE pointers so that a C programmer who is familiar with reading and writing files will immediately feel comfortable with reading and writing with Sockets. The SSL consists of three parts: the library, PortMaster, and utilities. The user of the SSL accesses it by linking programs to the SSL library. The PortMaster initializes connections between clients and servers. The PortMaster also supports a "firewall" facility to keep out socket requests from unapproved machines. The "firewall" is a file which contains Internet addresses for all approved machines. There are three utilities provided with the SSL. SKTDBG can be used to debug programs that make use of the SSL. SPMTABLE lists the servers and port numbers on requested machine(s). SRMSRVR tells the PortMaster to forcibly remove a server name from its list. The package also includes two example programs: multiskt.c, which makes multiple accepts on one server, and sktpoll.c, which repeatedly attempts to connect a client to some server at one second intervals. SSL is a machine independent library written in the C-language for computers connected via Ethernet using the TCP/IP protocol. It has been successfully compiled and implemented on a variety of platforms, including Sun series computers running SunOS, DEC VAX series computers running VMS, SGI computers running IRIX, DECstations running ULTRIX, DEC alpha AXPs running OSF/1, IBM RS/6000 computers running AIX, IBM PC and compatibles running BSD/386 UNIX and HP Apollo 3000/4000/9000/400T computers running HP-UX. SSL requires 45K of RAM to run under SunOS and 80K of RAM to run under VMS. For use on IBM PC series computers and compatibles running DOS, SSL requires Microsoft C 6.0 and the Wollongong TCP/IP package. Source code for sample programs and debugging tools are provided. The documentation is available on the distribution medium in TeX and PostScript formats. The standard distribution medium for SSL is a .25 inch streaming magnetic tape cartridge (QIC-24) in UNIX tar format. It is also available on a 3.5 inch diskette in UNIX tar format and a 5.25 inch 360K MS-DOS format diskette. The SSL was developed in 1992 and was updated in 1993.
SSL/TLS Vulnerability Detection Using Black Box Approach
NASA Astrophysics Data System (ADS)
Gunawan, D.; Sitorus, E. H.; Rahmat, R. F.; Hizriadi, A.
2018-03-01
Socket Secure Layer (SSL) and Transport Layer Security (TLS) are cryptographic protocols that provide data encryption to secure the communication over a network. However, in some cases, there are vulnerability found in the implementation of SSL/TLS because of weak cipher key, certificate validation error or session handling error. One of the most vulnerable SSL/TLS bugs is heartbleed. As the security is essential in data communication, this research aims to build a scanner that detect the SSL/TLS vulnerability by using black box approach. This research will focus on heartbleed case. In addition, this research also gathers information about existing SSL in the server. The black box approach is used to test the output of a system without knowing the process inside the system itself. For testing purpose, this research scanned websites and found that some of the websites still have SSL/TLS vulnerability. Thus, the black box approach can be used to detect the vulnerability without considering the source code and the process inside the application.
Safeguarding Digital Library Contents: Charging for Online Content.
ERIC Educational Resources Information Center
Herzberg, Amir
1998-01-01
Investigates the need for mechanisms for charging by digital libraries and other providers of online content, in particular for micropayments, i.e., charging for small amounts. The SSL (Secure Socket Layer) and SET (Secure Electronic Transactions) protocols for charge card payments and the MiniPay micropayment mechanism for charging small amounts…
Using software security analysis to verify the secure socket layer (SSL) protocol
NASA Technical Reports Server (NTRS)
Powell, John D.
2004-01-01
nal Aeronautics and Space Administration (NASA) have tens of thousands of networked computer systems and applications. Software Security vulnerabilities present risks such as lost or corrupted data, information the3, and unavailability of critical systems. These risks represent potentially enormous costs to NASA. The NASA Code Q research initiative 'Reducing Software Security Risk (RSSR) Trough an Integrated Approach '' offers, among its capabilities, formal verification of software security properties, through the use of model based verification (MBV) to address software security risks. [1,2,3,4,5,6] MBV is a formal approach to software assurance that combines analysis of software, via abstract models, with technology, such as model checkers, that provide automation of the mechanical portions of the analysis process. This paper will discuss: The need for formal analysis to assure software systems with respect to software and why testing alone cannot provide it. The means by which MBV with a Flexible Modeling Framework (FMF) accomplishes the necessary analysis task. An example of FMF style MBV in the verification of properties over the Secure Socket Layer (SSL) communication protocol as a demonstration.
Brubaker, Chad; Jana, Suman; Ray, Baishakhi; Khurshid, Sarfraz; Shmatikov, Vitaly
2014-01-01
Modern network security rests on the Secure Sockets Layer (SSL) and Transport Layer Security (TLS) protocols. Distributed systems, mobile and desktop applications, embedded devices, and all of secure Web rely on SSL/TLS for protection against network attacks. This protection critically depends on whether SSL/TLS clients correctly validate X.509 certificates presented by servers during the SSL/TLS handshake protocol. We design, implement, and apply the first methodology for large-scale testing of certificate validation logic in SSL/TLS implementations. Our first ingredient is "frankencerts," synthetic certificates that are randomly mutated from parts of real certificates and thus include unusual combinations of extensions and constraints. Our second ingredient is differential testing: if one SSL/TLS implementation accepts a certificate while another rejects the same certificate, we use the discrepancy as an oracle for finding flaws in individual implementations. Differential testing with frankencerts uncovered 208 discrepancies between popular SSL/TLS implementations such as OpenSSL, NSS, CyaSSL, GnuTLS, PolarSSL, MatrixSSL, etc. Many of them are caused by serious security vulnerabilities. For example, any server with a valid X.509 version 1 certificate can act as a rogue certificate authority and issue fake certificates for any domain, enabling man-in-the-middle attacks against MatrixSSL and GnuTLS. Several implementations also accept certificate authorities created by unauthorized issuers, as well as certificates not intended for server authentication. We also found serious vulnerabilities in how users are warned about certificate validation errors. When presented with an expired, self-signed certificate, NSS, Safari, and Chrome (on Linux) report that the certificate has expired-a low-risk, often ignored error-but not that the connection is insecure against a man-in-the-middle attack. These results demonstrate that automated adversarial testing with frankencerts is a powerful methodology for discovering security flaws in SSL/TLS implementations.
Brubaker, Chad; Jana, Suman; Ray, Baishakhi; Khurshid, Sarfraz; Shmatikov, Vitaly
2014-01-01
Modern network security rests on the Secure Sockets Layer (SSL) and Transport Layer Security (TLS) protocols. Distributed systems, mobile and desktop applications, embedded devices, and all of secure Web rely on SSL/TLS for protection against network attacks. This protection critically depends on whether SSL/TLS clients correctly validate X.509 certificates presented by servers during the SSL/TLS handshake protocol. We design, implement, and apply the first methodology for large-scale testing of certificate validation logic in SSL/TLS implementations. Our first ingredient is “frankencerts,” synthetic certificates that are randomly mutated from parts of real certificates and thus include unusual combinations of extensions and constraints. Our second ingredient is differential testing: if one SSL/TLS implementation accepts a certificate while another rejects the same certificate, we use the discrepancy as an oracle for finding flaws in individual implementations. Differential testing with frankencerts uncovered 208 discrepancies between popular SSL/TLS implementations such as OpenSSL, NSS, CyaSSL, GnuTLS, PolarSSL, MatrixSSL, etc. Many of them are caused by serious security vulnerabilities. For example, any server with a valid X.509 version 1 certificate can act as a rogue certificate authority and issue fake certificates for any domain, enabling man-in-the-middle attacks against MatrixSSL and GnuTLS. Several implementations also accept certificate authorities created by unauthorized issuers, as well as certificates not intended for server authentication. We also found serious vulnerabilities in how users are warned about certificate validation errors. When presented with an expired, self-signed certificate, NSS, Safari, and Chrome (on Linux) report that the certificate has expired—a low-risk, often ignored error—but not that the connection is insecure against a man-in-the-middle attack. These results demonstrate that automated adversarial testing with frankencerts is a powerful methodology for discovering security flaws in SSL/TLS implementations. PMID:25404868
A Scenario-Based Protocol Checker for Public-Key Authentication Scheme
NASA Astrophysics Data System (ADS)
Saito, Takamichi
Security protocol provides communication security for the internet. One of the important features of it is authentication with key exchange. Its correctness is a requirement of the whole of the communication security. In this paper, we introduce three attack models realized as their attack scenarios, and provide an authentication-protocol checker for applying three attack-scenarios based on the models. We also utilize it to check two popular security protocols: Secure SHell (SSH) and Secure Socket Layer/Transport Layer Security (SSL/TLS).
Mobile Virtual Private Networking
NASA Astrophysics Data System (ADS)
Pulkkis, Göran; Grahn, Kaj; Mårtens, Mathias; Mattsson, Jonny
Mobile Virtual Private Networking (VPN) solutions based on the Internet Security Protocol (IPSec), Transport Layer Security/Secure Socket Layer (SSL/TLS), Secure Shell (SSH), 3G/GPRS cellular networks, Mobile IP, and the presently experimental Host Identity Protocol (HIP) are described, compared and evaluated. Mobile VPN solutions based on HIP are recommended for future networking because of superior processing efficiency and network capacity demand features. Mobile VPN implementation issues associated with the IP protocol versions IPv4 and IPv6 are also evaluated. Mobile VPN implementation experiences are presented and discussed.
Domain Name Server Security (DNSSEC) Protocol Deployment
2014-10-01
all the time. For mobile devices, end-system validation is much more difficult due to the state of their networks, many of which do not allow...way to distribute keying information than the current public-key infrastructure (PKI) allows. In addition, it will take work to convince CDNs and...Control Protocol (TCP) or even DNS over Secure Sockets Layer (SSL). One of the important outcomes of our work is the realization that that a " mobile
Model based verification of the Secure Socket Layer (SSL) Protocol for NASA systems
NASA Technical Reports Server (NTRS)
Powell, John D.; Gilliam, David
2004-01-01
The National Aeronautics and Space Administration (NASA) has tens of thousands of networked computer systems and applications. Software Security vulnerabilities present risks such as lost or corrupted data, information theft, and unavailability of critical systems. These risks represent potentially enormous costs to NASA. The NASA Code Q research initiative 'Reducing Software Security Risk (RSSR) Trough an Integrated Approach' offers formal verification of information technology (IT), through the creation of a Software Security Assessment Instrument (SSAI), to address software security risks.
A Web-based, secure, light weight clinical multimedia data capture and display system.
Wang, S S; Starren, J
2000-01-01
Computer-based patient records are traditionally composed of textual data. Integration of multimedia data has been historically slow. Multimedia data such as image, audio, and video have been traditionally more difficult to handle. An implementation of a clinical system for multimedia data is discussed. The system implementation uses Java, Secure Socket Layer (SSL), and Oracle 8i. The system is on top of the Internet so it is architectural independent, cross-platform, cross-vendor, and secure. Design and implementations issues are discussed.
Access and accounting schemes of wireless broadband
NASA Astrophysics Data System (ADS)
Zhang, Jian; Huang, Benxiong; Wang, Yan; Yu, Xing
2004-04-01
In this paper, two wireless broadband access and accounting schemes were introduced. There are some differences in the client and the access router module between them. In one scheme, Secure Shell (SSH) protocol is used in the access system. The SSH server makes the authentication based on private key cryptography. The advantage of this scheme is the security of the user's information, and we have sophisticated access control. In the other scheme, Secure Sockets Layer (SSL) protocol is used the access system. It uses the technology of public privacy key. Nowadays, web browser generally combines HTTP and SSL protocol and we use the SSL protocol to implement the encryption of the data between the clients and the access route. The schemes are same in the radius sever part. Remote Authentication Dial in User Service (RADIUS), as a security protocol in the form of Client/Sever, is becoming an authentication/accounting protocol for standard access to the Internet. It will be explained in a flow chart. In our scheme, the access router serves as the client to the radius server.
A Web-based, secure, light weight clinical multimedia data capture and display system.
Wang, S. S.; Starren, J.
2000-01-01
Computer-based patient records are traditionally composed of textual data. Integration of multimedia data has been historically slow. Multimedia data such as image, audio, and video have been traditionally more difficult to handle. An implementation of a clinical system for multimedia data is discussed. The system implementation uses Java, Secure Socket Layer (SSL), and Oracle 8i. The system is on top of the Internet so it is architectural independent, cross-platform, cross-vendor, and secure. Design and implementations issues are discussed. Images Figure 2 Figure 3 PMID:11080014
DICOM image secure communications with Internet protocols IPv6 and IPv4.
Zhang, Jianguo; Yu, Fenghai; Sun, Jianyong; Yang, Yuanyuan; Liang, Chenwen
2007-01-01
Image-data transmission from one site to another through public network is usually characterized in term of privacy, authenticity, and integrity. In this paper, we first describe a general scenario about how image is delivered from one site to another through a wide-area network (WAN) with security features of data privacy, integrity, and authenticity. Second, we give the common implementation method of the digital imaging and communication in medicine (DICOM) image communication software library with IPv6/IPv4 for high-speed broadband Internet by using open-source software. Third, we discuss two major security-transmission methods, the IP security (IPSec) and the secure-socket layer (SSL) or transport-layer security (TLS), being used currently in medical-image-data communication with privacy support. Fourth, we describe a test schema of multiple-modality DICOM-image communications through TCP/IPv4 and TCP/IPv6 with different security methods, different security algorithms, and operating systems, and evaluate the test results. We found that there are tradeoff factors between choosing the IPsec and the SSL/TLS-based security implementation of IPv6/IPv4 protocols. If the WAN networks only use IPv6 such as in high-speed broadband Internet, the choice is IPsec-based security. If the networks are IPv4 or the combination of IPv6 and IPv4, it is better to use SSL/TLS security. The Linux platform has more security algorithms implemented than the Windows (XP) platform, and can achieve better performance in most experiments of IPv6 and IPv4-based DICOM-image communications. In teleradiology or enterprise-PACS applications, the Linux operating system may be the better choice as peer security gateways for both the IPsec and the SSL/TLS-based secure DICOM communications cross public networks.
NASA Astrophysics Data System (ADS)
Xu, Chong-Yao; Zheng, Xin; Xiong, Xiao-Ming
2017-02-01
With the development of Internet of Things (IoT) and the popularity of intelligent mobile terminals, smart home system has come into people’s vision. However, due to the high cost, complex installation and inconvenience, as well as network security issues, smart home system has not been popularized. In this paper, combined with Wi-Fi technology, Android system, cloud server and SSL security protocol, a new set of smart home system is designed, with low cost, easy operation, high security and stability. The system consists of Wi-Fi smart node (WSN), Android client and cloud server. In order to reduce system cost and complexity of the installation, each Wi-Fi transceiver, appliance control logic and data conversion in the WSN is setup by a single chip. In addition, all the data of the WSN can be uploaded to the server through the home router, without having to transit through the gateway. All the appliance status information and environmental information are preserved in the cloud server. Furthermore, to ensure the security of information, the Secure Sockets Layer (SSL) protocol is used in the WSN communication with the server. What’s more, to improve the comfort and simplify the operation, Android client is designed with room pattern to control home appliances more realistic, and more convenient.
Design and implementation of a high performance network security processor
NASA Astrophysics Data System (ADS)
Wang, Haixin; Bai, Guoqiang; Chen, Hongyi
2010-03-01
The last few years have seen many significant progresses in the field of application-specific processors. One example is network security processors (NSPs) that perform various cryptographic operations specified by network security protocols and help to offload the computation intensive burdens from network processors (NPs). This article presents a high performance NSP system architecture implementation intended for both internet protocol security (IPSec) and secure socket layer (SSL) protocol acceleration, which are widely employed in virtual private network (VPN) and e-commerce applications. The efficient dual one-way pipelined data transfer skeleton and optimised integration scheme of the heterogenous parallel crypto engine arrays lead to a Gbps rate NSP, which is programmable with domain specific descriptor-based instructions. The descriptor-based control flow fragments large data packets and distributes them to the crypto engine arrays, which fully utilises the parallel computation resources and improves the overall system data throughput. A prototyping platform for this NSP design is implemented with a Xilinx XC3S5000 based FPGA chip set. Results show that the design gives a peak throughput for the IPSec ESP tunnel mode of 2.85 Gbps with over 2100 full SSL handshakes per second at a clock rate of 95 MHz.
A Web-based telemedicine system for diabetic retinopathy screening using digital fundus photography.
Wei, Jack C; Valentino, Daniel J; Bell, Douglas S; Baker, Richard S
2006-02-01
The purpose was to design and implement a Web-based telemedicine system for diabetic retinopathy screening using digital fundus cameras and to make the software publicly available through Open Source release. The process of retinal imaging and case reviewing was modeled to optimize workflow and implement use of computer system. The Web-based system was built on Java Servlet and Java Server Pages (JSP) technologies. Apache Tomcat was chosen as the JSP engine, while MySQL was used as the main database and Laboratory of Neuro Imaging (LONI) Image Storage Architecture, from the LONI-UCLA, as the platform for image storage. For security, all data transmissions were carried over encrypted Internet connections such as Secure Socket Layer (SSL) and HyperText Transfer Protocol over SSL (HTTPS). User logins were required and access to patient data was logged for auditing. The system was deployed at Hubert H. Humphrey Comprehensive Health Center and Martin Luther King/Drew Medical Center of Los Angeles County Department of Health Services. Within 4 months, 1500 images of more than 650 patients were taken at Humphrey's Eye Clinic and successfully transferred to King/Drew's Department of Ophthalmology. This study demonstrates an effective architecture for remote diabetic retinopathy screening.
NASA Astrophysics Data System (ADS)
Xie, H. Y.; Ning, B. Q.; Zhao, X. K.; Hu, L. H.
2017-03-01
Using the Na lidar at Haikou (20.0°N, 110.3°E), the VHF coherent radar and the digital ionosonde both at Sanya (18.4°N, 109.6°E), cases of simultaneous observations of sporadic sodium layer (SSL), E-region field-aligned irregularities (FAI) and sporadic E layer (Es) in the mesosphere and lower thermosphere (MLT) region at low latitude of China are studied. It is found that SSL occurs simultaneously or follows the enhancement of Es and FAI. The Es, FAI and SSL descend slowly with time which is mostly controlled by the diurnal tide (DT). Besides, the interaction of gravity wave (GW) with tides can cause oscillations in FAI and SSL. Our observations support the neutralization of ions for SSL formation: when the metallic ions layer descents to the altitudes where models predict, the sodium ions convert rapidly to atomic Na that may form an SSL event. Moreover, the SSL peak density will increase (decrease) in the convergence (divergence) vertical shear region of zonal wind.
Security, privacy, and confidentiality issues on the Internet
Kelly, Grant; McKenzie, Bruce
2002-01-01
We introduce the issues around protecting information about patients and related data sent via the Internet. We begin by reviewing three concepts necessary to any discussion about data security in a healthcare environment: privacy, confidentiality, and consent. We are giving some advice on how to protect local data. Authentication and privacy of e-mail via encryption is offered by Pretty Good Privacy (PGP) and Secure Multipurpose Internet Mail Extensions (S/MIME). The de facto Internet standard for encrypting Web-based information interchanges is Secure Sockets Layer (SSL), more recently known as Transport Layer Security or TLS. There is a public key infrastructure process to `sign' a message whereby the private key of an individual can be used to `hash' the message. This can then be verified against the sender's public key. This ensures the data's authenticity and origin without conferring privacy, and is called a `digital signature'. The best protection against viruses is not opening e-mails from unknown sources or those containing unusual message headers. PMID:12554559
Security, privacy, and confidentiality issues on the Internet.
Kelly, Grant; McKenzie, Bruce
2002-01-01
We introduce the issues around protecting information about patients and related data sent via the Internet. We begin by reviewing three concepts necessary to any discussion about data security in a healthcare environment: privacy, confidentiality, and consent. We are giving some advice on how to protect local data. Authentication and privacy of e-mail via encryption is offered by Pretty Good Privacy (PGP) and Secure Multipurpose Internet Mail Extensions (S/MIME). The de facto Internet standard for encrypting Web-based information interchanges is Secure Sockets Layer (SSL), more recently known as Transport Layer Security or TLS. There is a public key infrastructure process to 'sign' a message whereby the private key of an individual can be used to 'hash' the message. This can then be verified against the sender's public key. This ensures the data's authenticity and origin without conferring privacy, and is called a 'digital signature'. The best protection against viruses is not opening e-mails from unknown sources or those containing unusual message headers.
2016-10-01
laminated rigid frame to reduce thermal layers, increase flexibility and comfort while retaining ischial containment. In contrast, a Sub-I design has...design is comprised of a flexible interface and minimal laminated rigid frame to reduce thermal layers, increase flexibility and comfort while...AWARD NUMBER: W81XWH-15-1-0410 TITLE: The Effect of Prosthetic Socket Interface Design on Socket Comfort , Residual Limb Health, and Function
NASA Astrophysics Data System (ADS)
Haneda, Kiyofumi; Koyama, Tadashi
2005-04-01
We developed a secure system that minimizes staff workload and secures safety of a medical information system. In this study, we assess the legal security requirements and risks occurring from the use of digitized data. We then analyze the security measures for ways of reducing these risks. In the analysis, not only safety, but also costs of security measures and ease of operability are taken into consideration. Finally, we assess the effectiveness of security measures by employing our system in small-sized medical institution. As a result of the current study, we developed and implemented several security measures, such as authentications, cryptography, data back-up, and secure sockets layer protocol (SSL) in our system. In conclusion, the cost for the introduction and maintenance of a system is one of the primary difficulties with its employment by a small-sized institution. However, with recent reductions in the price of computers, and certain advantages of small-sized medical institutions, the development of an efficient system configuration has become possible.
A statistical study of sporadic sodium layer observed by Sodium lidar at Hefei (31.8° N, 117.3° E)
NASA Astrophysics Data System (ADS)
Dou, X.-K.; Xue, X.-H.; Chen, T.-D.; Wan, W.-X.; Cheng, X.-W.; Li, T.; Chen, C.; Qiu, S.; Chen, Z.-Y.
2009-06-01
Sodium lidar observations of sporadic sodium layers (SSLs) during the past 3 years at a mid-latitude location (Hefei, China, 31.8° N, 117.3° E) are reported in this paper. From 64 SSL events detected in about 900 h of observation, an SSL occurrence rate of 1 event every 14 h at our location was obtained. This result, combined with previous studies, reveals that the SSL occurrence can be relatively frequent at some mid-latitude locations. Statistical analysis of main parameters for the 64 SSL events was performed. By examining the corresponding data from an ionosonde, a considerable correlation was found with a Pearson coefficient of 0.66 between seasonal variations of SSL and those of sporadic E (Es) during nighttime, which was in line with the research by Nagasawa and Abo (1995). From comparison between observations from the University of Science and Technology of China (USTC) lidar and from Wuhan Institute of Physics and Mathematics (WIPM) lidar (Wuhan, China, 31° N, 114° E), the minimum horizontal range for some events was estimated to be over 500 km.
An Analysis of Two Layers of Encryption to Protect Network Traffic
2010-06-01
Published: 06/18/2001 CVSS Severity: 7.5 (HIGH) CVE-2001-1141 Summary: The Pseudo-Random Number Generator (PRNG) in SSLeay and OpenSSL be- fore 0.9.6b allows...x509cert function in KAME Racoon successfully verifies certifi- cates even when OpenSSL validation fails, which could allow remote attackers to...montgomery function in crypto/bn/bn mont.c in OpenSSL 0.9.8e and earlier does not properly perform Montgomery multiplication, which might allow local users to
Method of Performance-Aware Security of Unicast Communication in Hybrid Satellite Networks
NASA Technical Reports Server (NTRS)
Baras, John S. (Inventor); Roy-Chowdhury, Ayan (Inventor)
2014-01-01
A method and apparatus utilizes Layered IPSEC (LES) protocol as an alternative to IPSEC for network-layer security including a modification to the Internet Key Exchange protocol. For application-level security of web browsing with acceptable end-to-end delay, the Dual-mode SSL protocol (DSSL) is used instead of SSL. The LES and DSSL protocols achieve desired end-to-end communication security while allowing the TCP and HTTP proxy servers to function correctly.
Electronic patient record and archive of records in Cardio.net system for telecardiology.
Sierdziński, Janusz; Karpiński, Grzegorz
2003-01-01
In modern medicine the well structured patient data set, fast access to it and reporting capability become an important question. With the dynamic development of information technology (IT) such question is solved via building electronic patient record (EPR) archives. We then obtain fast access to patient data, diagnostic and treatment protocols etc. It results in more efficient, better and cheaper treatment. The aim of the work was to design a uniform Electronic Patient Record, implemented in cardio.net system for telecardiology allowing the co-operation among regional hospitals and reference centers. It includes questionnaires for demographic data and questionnaires supporting doctor's work (initial diagnosis, final diagnosis, history and physical, ECG at the discharge, applied treatment, additional tests, drugs, daily and periodical reports). The browser is implemented in EPR archive to facilitate data retrieval. Several tools for creating EPR and EPR archive were used such as: XML, PHP, Java Script and MySQL. The separate question is the security of data on WWW server. The security is ensured via Security Socket Layer (SSL) protocols and other tools. EPR in Cardio.net system is a module enabling the co-work of many physicians and the communication among different medical centers.
Secure UNIX socket-based controlling system for high-throughput protein crystallography experiments.
Gaponov, Yurii; Igarashi, Noriyuki; Hiraki, Masahiko; Sasajima, Kumiko; Matsugaki, Naohiro; Suzuki, Mamoru; Kosuge, Takashi; Wakatsuki, Soichi
2004-01-01
A control system for high-throughput protein crystallography experiments has been developed based on a multilevel secure (SSL v2/v3) UNIX socket under the Linux operating system. Main features of protein crystallography experiments (purification, crystallization, loop preparation, data collecting, data processing) are dealt with by the software. All information necessary to perform protein crystallography experiments is stored (except raw X-ray data, that are stored in Network File Server) in a relational database (MySQL). The system consists of several servers and clients. TCP/IP secure UNIX sockets with four predefined behaviors [(a) listening to a request followed by a reply, (b) sending a request and waiting for a reply, (c) listening to a broadcast message, and (d) sending a broadcast message] support communications between all servers and clients allowing one to control experiments, view data, edit experimental conditions and perform data processing remotely. The usage of the interface software is well suited for developing well organized control software with a hierarchical structure of different software units (Gaponov et al., 1998), which will pass and receive different types of information. All communication is divided into two parts: low and top levels. Large and complicated control tasks are split into several smaller ones, which can be processed by control clients independently. For communicating with experimental equipment (beamline optical elements, robots, and specialized experimental equipment etc.), the STARS server, developed at the Photon Factory, is used (Kosuge et al., 2002). The STARS server allows any application with an open socket to be connected with any other clients that control experimental equipment. Majority of the source code is written in C/C++. GUI modules of the system were built mainly using Glade user interface builder for GTK+ and Gnome under Red Hat Linux 7.1 operating system.
Arun, S; Kanagaraj, S
2016-06-01
A socket plays a vital role in giving the comfort to the amputees. However, the accumulation of heat inside the socket and its weight led to increase their metabolic cost. Hence, an attempt was made to increase the performance of the epoxy based sandwich composites to be used for the socket by reinforcing multiwalled carbon nanotubes (MWCNT), which was varied from 0.1 to 0.5wt%. It was homogeneously dispersed in epoxy to obtain the desired properties, where the enhancement of thermal conductivity, compressive strength and modulus of epoxy was observed to be 76.7%, 62.6% and 20.2%, respectively at 0.3wt% of MWCNT concentration beyond which the mechanical properties were found to be decreased. Hence, the epoxy, E-glass plain fabric, 2-10 layers of stockinet and 0.3wt% of MWCNT were used to prepare the sandwich composites. The flexural strength and thermal conductivity of 0.3wt% of MWCNT reinforced sandwich composites were found to be improved by 11.38±1.5% and 29.8±1.3% for the 4-10 layers and up to 10 layers of stockinet, respectively compared to unreinforced sandwich composites, which helped to reduce the weight of the socket and decrease the heat accumulation inside the socket. Thus, it is suggested to be explored for the application of socket in trans-femoral amputees to increase their comfort level by decreasing the metabolic cost. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Xue, X. H.; Dou, X. K.; Lei, J.; Chen, J. S.; Ding, Z. H.; Li, T.; Gao, Q.; Tang, W. W.; Cheng, X. W.; Wei, K.
2013-05-01
We report two lower thermospheric-enhanced sodium layer (TeSL) cases observed at a low-latitude station, Lijiang, China (26.7°N, 100.0°E), on 10 March and 10 April 2012, respectively. The TeSLs in the two cases were located at altitudes near 122 and 112 km, respectively. In addition, strong sporadic sodium layers (SSLs) near 100 km accompanied the TeSL observed on 10 March 2012. Both the TeSLs and SSLs exhibited tidal-induced downward motion. The adjacent ground-based and space-borne ionospheric radio observations showed strong Es layers before the appearance of the TeSLs, suggesting an " Es- TeSLs (SSLs)" chain formed through the tidal wind shear mechanism. Assuming that the vertical tidal wavelengths remain unchanged, it is found that in different regions caused by the tidal wind shear, different TeSLs evolution processes are expected: (1) in a tidal-convergence region, a TeSL/SSL with a downward propagation phase is enhanced due to a rapid decrease in the Na+lifetime at the lower altitude; (2) in an ion convergence-divergence interface region, a TeSL/SSL will still follow the tidal downward phase progression, but sodium density does not exhibit evident enhancement; and (3) when a TeSL/SSL enters into a tidal wind-divergence zone, the layer density tends to decrease.
A new directly moulded patellar-tendon-bearing socket.
Boot, D A; Young, N J
1985-08-01
Silicone rubbers and casting tapes individually have previously been used in the manufacture of sockets (Swanson, 1972; Sweitzer, 1973; Ruder, 1977; Graves, 1980; Aqualite, 1982). The authors believe that the present combination of these materials to manufacture a directly moulded socket with a complete silicone rubber lining of variable thickness has not previously been described. The new socket, after addition of the modular components, allows fitting of an aligned below-knee prosthesis within three hours. The socket (Fig. 1.) is made directly on the below-knee stump, can be completed with experience in an hour and does not require the use of specialized equipment. The socket consists of an outer supportive Scotchflex layer inside which is a lining of soft smooth biocompatible silicone rubber of deliberately variable thickness to allow pressure tolerant areas to accept more load and pressure sensitive areas to accept less load (Fig.2). The thicker areas of silicone are produced by applying carefully cut Plastazote pads to the pressure sensitive areas. The thickness and extent of the pads is individually assessed according to the estimated sensitivity of the particular area (Fig. 3). The Scotchflex socket is then manufactured directly on the below-knee stump with these pads applied. The pads are then removed prior to insertion of a semi-liquid silicone rubber. Thus, when the socket with the liquid silicone rubber is re-applied to the stump, the space produced by the pads is filled by the rubber which then sets at room temperature. In this way a layer of variable thickness is produced.(ABSTRACT TRUNCATED AT 250 WORDS)
Prosthetics & Orthotics Manufacturing Initiative (POMI)
2012-12-21
could also allow for ‘virtual innovation,’ the testing of very novel socket designs without ever risking a patient’s well-being. In order to inform...that RL so that a computer aided design (CAD) socket can be fabricated for that individual. 3. Test the fit of the CAD socket through...developed a 4 layer braid laminate design that worked for manufacturing purposes but there was no testing of the laminate to determine if all strength
Sporadic and thermospheric enhanced sodium layers observed by a lidar chain over China
NASA Astrophysics Data System (ADS)
Dou, X. K.; Qiu, S. C.; Xue, X. H.; Chen, T. D.; Ning, B. Q.
2013-10-01
We report the statistical features of sporadic sodium layers (SSLs) and the thermospheric enhanced sodium layers (TeSLs) observed by a lidar chain located at Beijing (40.2°N, 116.2°E), Hefei (31.8°N, 117.3°E), Wuhan (30.5°N, 114.4°E), and Haikou (19.5°N, 109.1°E). The average SSL occurrence rate was approximately 46.0, 12.3, 13.8, and 15.0 h per SSL at Beijing, Hefei, Wuhan, and Haikou, respectively. However, the TeSLs occurred relatively infrequently and were more likely to appear at low and high latitudinal sites. Both the SSLs and TeSLs at four lidar sites showed evident summer enhancements and correlated well with Es (foEs>4 MHz). The coobservations of SSLs at three lidar site pairs, i.e., Hefei-Beijing, Hefei-Wuhan, and Hefei-Beijing, indicated that a large-scale SSL extended horizontally for at least a few hundred kilometers and exhibited a tidal-induced modulation. Moreover, the SSLs were better correlated for the Hefei-Wuhan and Hefei-Haikou pairs than the Hefei-Beijing pair, which suggested a difference in the dynamical/chemical process in mesosphere and lower thermosphere (MLT) between the Beijing site and the other sites.
Sporadic and Thermospheric Enhanced Sodium Layers Observed by a Lidar Chain over China
NASA Astrophysics Data System (ADS)
Xue, X.
2013-12-01
We report the statistical features of sporadic sodium layers (SSLs) and the thermospheric enhanced sodium layers (TeSLs) observed by a lidar chain located at Beijing (40.2N,116.2E), Hefei (31.8N, 117.3E), Wuhan (30.5N, 114.4E), and Haikou (19.5N, 109.1E). The average SSL occurrence rate was approximately 46.0, 12.3, 13.8, and 15.0 hr per SSL at Beijing, Hefei, Wuhan, and Haikou, respectively. However, the TeSLs occurred relatively infrequently and were more likely to appear at low and high latitudinal sites. Both the SSLs and TeSLs at four lidar sites showed evident summer enhancements and correlated well with Es (foEs>4MHz). The co-observations of SSLs at three lidar site pairs, i.e., Hefei -- Beijing, Hefei -- Wuhan and Hefei -- Beijing, indicated that a large-scale SSL extended horizontally for at least a few hundred kilometers and exhibited a tidal-induced modulation. Moreover, the SSLs were better correlated for the Hefei -- Wuhan and Hefei -- Haikou pairs than the Hefei -- Beijing pair, which suggested a difference in the dynamical/chemical process in mesosphere and lower thermosphere (MLT) between the Beijing site and the other sites.
Surface Lipids as Multifunctional Mediators of Skin Responses to Environmental Stimuli
De Luca, Chiara; Valacchi, Giuseppe
2010-01-01
Skin surface lipid (SSL) film is a mixture of sebum and keratinocyte membrane lipids, protecting skin from environment. Its composition is unique for the high percentage of long chain fatty acids, and of the polyterpenoid squalene, absent in other human tissues, and in non-human Primates sebum. Here, the still incomplete body of information on SSL as mediators of external chemical, physical, and microbial signals and stressors is revised, focusing on the central event of the continuous oxidative modification induced by the metabolic activity of residential and pathological microbial flora, natural or iatrogenic UV irradiation, exposure to chemicals and cosmetics. Once alpha-tocopherol and ubiquinol-10 antioxidant defences of SSL are overcome, oxidation of squalene and cholesterol gives rise to reactive by-products penetrating deeper into skin layers, to mediate local defensive inflammatory, photo-protective, immune reactions or, at higher concentrations, inducing local but also systemic immune depression, ultimately implicating skin cancerogenesis. Qualitative modifications of SSL represent a pathogenetic sign of diagnostic value in dermatological disorders involving altered sebum production, like pytiriasis versicolor, acne, atopic or seborrheic dermatitis, as well as photo-aging. Achievements of nutriceutical interventions aimed at restoring normal SSL composition and homeostasis are discussed, as feasible therapeutic goals and major means of photo-protection. PMID:20981292
Network Computing Infrastructure to Share Tools and Data in Global Nuclear Energy Partnership
NASA Astrophysics Data System (ADS)
Kim, Guehee; Suzuki, Yoshio; Teshima, Naoya
CCSE/JAEA (Center for Computational Science and e-Systems/Japan Atomic Energy Agency) integrated a prototype system of a network computing infrastructure for sharing tools and data to support the U.S. and Japan collaboration in GNEP (Global Nuclear Energy Partnership). We focused on three technical issues to apply our information process infrastructure, which are accessibility, security, and usability. In designing the prototype system, we integrated and improved both network and Web technologies. For the accessibility issue, we adopted SSL-VPN (Security Socket Layer-Virtual Private Network) technology for the access beyond firewalls. For the security issue, we developed an authentication gateway based on the PKI (Public Key Infrastructure) authentication mechanism to strengthen the security. Also, we set fine access control policy to shared tools and data and used shared key based encryption method to protect tools and data against leakage to third parties. For the usability issue, we chose Web browsers as user interface and developed Web application to provide functions to support sharing tools and data. By using WebDAV (Web-based Distributed Authoring and Versioning) function, users can manipulate shared tools and data through the Windows-like folder environment. We implemented the prototype system in Grid infrastructure for atomic energy research: AEGIS (Atomic Energy Grid Infrastructure) developed by CCSE/JAEA. The prototype system was applied for the trial use in the first period of GNEP.
Normalization of load and clearance effects in ball-in-socket-like replacements.
Ciavarella, M; Strozzi, A; Baldini, A; Giacopini, M
2007-08-01
A normalizing loading parameter useful in summarising the mechanical response of plane pin-in-plate-like contacts is extended to axisymmetric ball-in-socket-like contacts. An example addressing a compliant layered artificial hip joint is presented, and the usefulness of the normalizing loading parameter is evidenced.
NASA Astrophysics Data System (ADS)
Akiha, Fumihiro; Hashida, Gen; Makabe, Ryosuke; Hattori, Hiroshi; Sasaki, Hiroshi
2017-06-01
We investigated shelled pteropod abundance and biomass with a 100-μm closing net, and their estimated downward fluxes using a sediment trap installed in a drifter buoy in the Indian sector of the Antarctic Ocean during the austral summer. Over 90% pteropod abundance was distributed in the upper 50 m; 70-100% were immature veligers. Limacina retroversa was dominant in the >0.2 mm individuals north of 60°S, L. helicina dominated south of 62°S, while populations around 60-62°S were mixed. Unidentifiable small Limacina spp. (ssL) were highly abundant in the upper 50 m at 60°S, 63°S, and 64°S on 110°E and 63°S on 115°E, although their estimated particulate organic carbon (POC) biomasses were less than that of Limacina adults. Adult females bearing egg clusters were found in the 0-50 m layer; the veligers likely grew within a short period. The mean downward flux of ssL and veligers at 70 m around 60°S, 110°E was 5.1 ± 1.6 × 103 ind. m-2 d-1 (0.6 ± 0.2 mg C m-2 d-1), which was 3.8% of the integrated ssL and veligers in the upper 70 m, suggesting that at least 4% of the veligers were produced daily in the surface layers. The mid-summer spawned ssL and veligers likely contributed to the subsequent increase in large pteropods in the area.
Ahn, Jae-Jin; Shin, Hong-In
2008-01-01
To investigate postextraction bone formation over time in both diseased and healthy sockets. Core specimens of healing tissues following tooth extraction were obtained at the time of implant placement in patients treated between October 2005 and December 2007. A disease group and a control group were classified according to socket examination at the time of extraction. The biopsy specimens were analyzed histomorphometrically to measure the dimensional changes among 3 tissue types: epithelial layer, connective tissue area, and new bone tissue area. Fifty-five specimens from sites of previously advanced periodontal disease from 45 patients were included in the disease group. Another 12 specimens of previously healthy extraction sockets were collected from 12 different patients as a control. The postextraction period of the disease group varied from 2 to 42 weeks. In the disease group, connective tissue occupied most of the socket during the first 4 weeks. New bone area progressively replaced the connective tissue area after the first 4 weeks. The area proportion of new bone tissue exceeded that of connective tissue by 14 weeks. After 20 weeks, most extraction sockets in the disease group demonstrated continuous new bone formation. The control group exhibited almost complete socket healing after 10 weeks, with no more new bone formation after 20 weeks. Osseous regeneration in the diseased sockets developed more slowly than in the disease-free sockets. After 16 weeks, new bone area exceeded 50% of the total newly regenerated tissue in the sockets with severe periodontal destruction. In the control group, after 8 weeks, new bone area exceeded 50% of the total tissue.
Al-Fakih, Ebrahim A.; Abu Osman, Noor Azuan; Eshraghi, Arezoo; Adikan, Faisal Rafiq Mahamd
2013-01-01
This study presents the first investigation into the capability of fiber Bragg grating (FBG) sensors to measure interface pressure between the stump and the prosthetic sockets of a trans-tibial amputee. FBG element(s) were recoated with and embedded in a thin layer of epoxy material to form a sensing pad, which was in turn embedded in a silicone polymer material to form a pressure sensor. The sensor was tested in real time by inserting a heavy-duty balloon into the socket and inflating it by using an air compressor. This test was conducted to examine the sensitivity and repeatability of the sensor when subjected to pressure from the stump of the trans-tibial amputee and to mimic the actual environment of the amputee's Patellar Tendon (PT) bar. The sensor exhibited a sensitivity of 127 pm/N and a maximum FSO hysteresis of around ∼0.09 in real-time operation. Very good reliability was achieved when the sensor was utilized for in situ measurements. This study may lead to smart FBG-based amputee stump/socket structures for pressure monitoring in amputee socket systems, which will result in better-designed prosthetic sockets that ensure improved patient satisfaction. PMID:23941909
Al-Fakih, Ebrahim A; Osman, Noor Azuan Abu; Eshraghi, Arezoo; Adikan, Faisal Rafiq Mahamd
2013-08-12
This study presents the first investigation into the capability of fiber Bragg grating (FBG) sensors to measure interface pressure between the stump and the prosthetic sockets of a trans-tibial amputee. FBG element(s) were recoated with and embedded in a thin layer of epoxy material to form a sensing pad, which was in turn embedded in a silicone polymer material to form a pressure sensor. The sensor was tested in real time by inserting a heavy-duty balloon into the socket and inflating it by using an air compressor. This test was conducted to examine the sensitivity and repeatability of the sensor when subjected to pressure from the stump of the trans-tibial amputee and to mimic the actual environment of the amputee's Patellar Tendon (PT) bar. The sensor exhibited a sensitivity of 127 pm/N and a maximum FSO hysteresis of around ~0.09 in real-time operation. Very good reliability was achieved when the sensor was utilized for in situ measurements. This study may lead to smart FBG-based amputee stump/socket structures for pressure monitoring in amputee socket systems, which will result in better-designed prosthetic sockets that ensure improved patient satisfaction.
NASA Astrophysics Data System (ADS)
Al-Fakih, Ebrahim; Arifin, Nooranida; Pirouzi, Gholamhossein; Mahamd Adikan, Faisal Rafiq; Shasmin, Hanie Nadia; Abu Osman, Noor Azuan
2017-08-01
This paper presents a fiber Bragg grating (FBG)-instrumented prosthetic silicone liner that provides cushioning for the residual limb and can successfully measure interface pressures inside prosthetic sockets of lower-limb amputees in a simple and practical means of sensing. The liner is made of two silicone layers between which 12 FBG sensors were embedded at locations of clinical interest. The sensors were then calibrated using a custom calibration platform that mimics a real-life situation. Afterward, a custom gait simulating machine was built to test the liner performance during an amputee's simulated gait. To validate the findings, the results were compared to those obtained by the commonly used F-socket mats. As the statistical findings reveal, both pressure mapping methods measured the interface pressure in a consistent way, with no significant difference (P-values ≥0.05). This pressure mapping technique in the form of a prosthetic liner will allow prosthetics professionals to quickly and accurately create an overall picture of the interface pressure distribution inside sockets in research and clinical settings, thereby improving the socket fit and amputee's satisfaction.
JPARSS: A Java Parallel Network Package for Grid Computing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Jie; Akers, Walter; Chen, Ying
2002-03-01
The emergence of high speed wide area networks makes grid computinga reality. However grid applications that need reliable data transfer still have difficulties to achieve optimal TCP performance due to network tuning of TCP window size to improve bandwidth and to reduce latency on a high speed wide area network. This paper presents a Java package called JPARSS (Java Parallel Secure Stream (Socket)) that divides data into partitions that are sent over several parallel Java streams simultaneously and allows Java or Web applications to achieve optimal TCP performance in a grid environment without the necessity of tuning TCP window size.more » This package enables single sign-on, certificate delegation and secure or plain-text data transfer using several security components based on X.509 certificate and SSL. Several experiments will be presented to show that using Java parallelstreams is more effective than tuning TCP window size. In addition a simple architecture using Web services« less
Utilizing Internet Technologies in Observatory Control Systems
NASA Astrophysics Data System (ADS)
Cording, Dean
2002-12-01
The 'Internet boom' of the past few years has spurred the development of a number of technologies to provide services such as secure communications, reliable messaging, information publishing and application distribution for commercial applications. Over the same period, a new generation of computer languages have also developed to provide object oriented design and development, improved reliability, and cross platform compatibility. Whilst the business models of the 'dot.com' era proved to be largely unviable, the technologies that they were based upon have survived and have matured to the point were they can now be utilized to build secure, robust and complete observatory control control systems. This paper will describe how Electro Optic Systems has utilized these technologies in the development of its third generation Robotic Observatory Control System (ROCS). ROCS provides an extremely flexible configuration capability within a control system structure to provide truly autonomous robotic observatory operation including observation scheduling. ROCS was built using Internet technologies such as Java, Java Messaging Service (JMS), Lightweight Directory Access Protocol (LDAP), Secure Sockets Layer (SSL), eXtendible Markup Language (XML), Hypertext Transport Protocol (HTTP) and Java WebStart. ROCS was designed to be capable of controlling all aspects of an observatory and be able to be reconfigured to handle changing equipment configurations or user requirements without the need for an expert computer programmer. ROCS consists of many small components, each designed to perform a specific task, with the configuration of the system specified using a simple meta language. The use of small components facilitates testing and makes it possible to prove that the system is correct.
75 FR 76428 - Privacy Act of 1974; System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-08
..., country, organization, phone, fax, mobile, pager, Defense Switched Network (DSN) phone, other fax, other... to populate and maintain personal data elements in DoD Component networks and systems, such as.../Transport Layer Security (SSL/ TLS) connections, access control lists, file system permissions, intrusion...
Kurukji, D; Pichot, R; Spyropoulos, F; Norton, I T
2013-11-01
The ability of a food ingredient, sodium stearoyllactylate (SSL), to stabilise oil-in-water (O/W) emulsions against coalescence was investigated, and closely linked to its capacity to act as a Pickering stabiliser. Results showed that emulsion stability could be achieved with a relatively low SSL concentration (≥0.1 wt%), and cryogenic-scanning electron microscopy (cryo-SEM) visualisation of emulsion structure revealed the presence of colloidal SSL aggregates adsorbed at the oil-water interface. Surface properties of SSL could be modified by altering the size of these aggregates in water; a faster decrease in surface tension was observed when SSL dispersions were subjected to high pressure homogenisation (HPH). The rate of SSL adsorption at the sunflower oil-water interface also increased after HPH, and a higher interfacial tension (IFT) was observed with increasing SSL concentration. Differential scanning calorimetry (DSC) enabled a comparison of the thermal behaviour of SSL in aqueous dispersions with SSL-stabilised O/W emulsions. SSL melting enthalpy depended on emulsion interfacial area and the corresponding DSC data was used to determine the amount of SSL adsorbed at the oil-water interface. An idealised theoretical interfacial coverage calculation based on Pickering emulsion theory was in general agreement with the mass of SSL adsorbed as predicted by DSC. Copyright © 2013 The Authors. Published by Elsevier Inc. All rights reserved.
Al-Fakih, Ebrahim; Arifin, Nooranida; Pirouzi, Gholamhossein; Mahamd Adikan, Faisal Rafiq; Shasmin, Hanie Nadia; Abu Osman, Noor Azuan
2017-08-01
This paper presents a fiber Bragg grating (FBG)-instrumented prosthetic silicone liner that provides cushioning for the residual limb and can successfully measure interface pressures inside prosthetic sockets of lower-limb amputees in a simple and practical means of sensing. The liner is made of two silicone layers between which 12 FBG sensors were embedded at locations of clinical interest. The sensors were then calibrated using a custom calibration platform that mimics a real-life situation. Afterward, a custom gait simulating machine was built to test the liner performance during an amputee's simulated gait. To validate the findings, the results were compared to those obtained by the commonly used F-socket mats. As the statistical findings reveal, both pressure mapping methods measured the interface pressure in a consistent way, with no significant difference (P-values ≥0.05). This pressure mapping technique in the form of a prosthetic liner will allow prosthetics professionals to quickly and accurately create an overall picture of the interface pressure distribution inside sockets in research and clinical settings, thereby improving the socket fit and amputee's satisfaction. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).
75 FR 69644 - Privacy Act of 1974; System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-15
..., organization, phone, fax, mobile, pager, Defense Switched Network (DSN) phone, other fax, other mobile, other.../Transport Layer Security (SSL/ TLS) connections, access control lists, file system permissions, intrusion detection and prevention systems and log monitoring. Complete access to all records is restricted to and...
Koymans, Kirsten J; Goldmann, Oliver; Karlsson, Christofer A Q; Sital, Wiedjai; Thänert, Robert; Bisschop, Adinda; Vrieling, Manouk; Malmström, Johan; van Kessel, Kok P M; de Haas, Carla J C; van Strijp, Jos A G; Medina, Eva
2017-01-01
Toll-like receptor (TLR) signaling is important in the initiation of immune responses and subsequent instigation of adaptive immunity. TLR2 recognizes bacterial lipoproteins and plays a central role in the host defense against bacterial infections, including those caused by Staphylococcus aureus. Many studies have demonstrated the importance of TLR2 in murine S. aureus infection. S. aureus evades TLR2 activation by secreting two proteins, staphylococcal superantigen-like protein 3 (SSL3) and 4 (SSL4). In this study, we demonstrate that antibodies against SSL3 and SSL4 are found in healthy individuals, indicating that humans are exposed to these proteins during S. aureus colonization or infection. To investigate the TLR2-antagonistic properties of SSL3 and SSL4, we compared the infection with wild-type and SSL3/4 knockout S. aureus strains in an intravenous murine infection model. Direct evaluation of the contribution of SSL3/4 to infection pathogenesis was hindered by the fact that the SSLs were not expressed in the murine system. To circumvent this limitation, an SSL3-overproducing strain (pLukM-SSL3) was generated, resulting in constitutive expression of SSL3. pLukM-SSL3 exhibited increased virulence compared to the parental strain in a murine model that was found to be TLR2 dependent. Altogether, these data indicate that SSL3 contributes to S. aureus virulence in vivo. © 2017 S. Karger AG, Basel.
75 FR 69645 - Privacy Act of 1974; System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-15
..., pager, Defense Switched Network (DSN) phone, other fax, other mobile, other pager, city, zip code, post... system may used to populate and maintain persona data elements in DoD component networks and systems.../Transport Layer Security (SSL/ TLS) connections, access control lists, file system permissions, intrusion...
Wang, Song; Wang, Fei; Liao, Zhenhua; Wang, Qingliang; Liu, Yuhong; Liu, Weiqiang
2015-10-01
A ball-on-socket contact configuration was designed to simulate an artificial cervical disk in structure. UHMWPE (ultra high molecular weight polyethylene) hot pressed by powders and Ti6Al4V alloy were selected as the material combination of ball and socket. The socket surface was coated by a ~500 nm C-DLC (carbon ion implantation-diamond like carbon) mixed layer to improve its surface nano hardness and wear resistance. The torsional fretting wear behavior of the ball-on-socket model was tested at different angular displacements under 25% bovine serum lubrication with an axial force of 100 N to obtain more realistic results with that in vivo. The fretting running regimes and wear damage characteristics as well as wear mechanisms for both ball and socket were studied based on 2D (two dimension) optical microscope, SEM (scanning electron microscope) and 3D (three dimension) profiles. With the increase of angular displacement amplitude from 1° to 7°, three types of T-θ (Torsional torque-angular displacement amplitude) curves (i.e., linear, elliptical and parallelogram loops) corresponding to running regimes of PSR (partial slip regime), MR (mixed regime) and SR (slip regime) were observed and analyzed. Both the central region and the edge zone of the ball and socket were damaged. The worn surfaces were characterized by wear scratches and wear debris. In addition, more severe wear damage and more wear debris appeared on the central region of the socket at higher angular displacement amplitude. The dominant damage mechanism was a mix of surface scratch, adhesive wear and abrasive wear for the UHMWPE ball while that for the coated socket was abrasive wear by PE particles and some polishing and rolling process on the raised overgrown DLC grains. The frictional kinetic behavior, wear type, damage region and damage mechanism for the ball-on-socket model revealed significant differences with those of a ball-on-flat contact while showing better consistency with that of in vitro cervical prosthesis simulations according to the literature. Copyright © 2015. Published by Elsevier B.V.
Cross-Domain Semi-Supervised Learning Using Feature Formulation.
Xingquan Zhu
2011-12-01
Semi-Supervised Learning (SSL) traditionally makes use of unlabeled samples by including them into the training set through an automated labeling process. Such a primitive Semi-Supervised Learning (pSSL) approach suffers from a number of disadvantages including false labeling and incapable of utilizing out-of-domain samples. In this paper, we propose a formative Semi-Supervised Learning (fSSL) framework which explores hidden features between labeled and unlabeled samples to achieve semi-supervised learning. fSSL regards that both labeled and unlabeled samples are generated from some hidden concepts with labeling information partially observable for some samples. The key of the fSSL is to recover the hidden concepts, and take them as new features to link labeled and unlabeled samples for semi-supervised learning. Because unlabeled samples are only used to generate new features, but not to be explicitly included in the training set like pSSL does, fSSL overcomes the inherent disadvantages of the traditional pSSL methods, especially for samples not within the same domain as the labeled instances. Experimental results and comparisons demonstrate that fSSL significantly outperforms pSSL-based methods for both within-domain and cross-domain semi-supervised learning.
Design of Multilayer Dual-Band BPF and Diplexer with Zeros Implantation Using Suspended Stripline
NASA Astrophysics Data System (ADS)
Ho, Min-Hua; Hsu, Wei-Hong
In this paper, a dual-band bandpass filter (BPF) of multilayer suspended stripline (SSL) structure and an SSL diplexer composed of a low-pass filter (LPF) and a high-pass filter (HPF) are proposed. Bandstop structure creating transmission zeros is adopted in the BPF and diplexer, enhancing the signal selectivity of the former and increasing the isolation between the diverting ports of the latter. The dual-band BPF possesses two distinct bandpass structures and a bandstop circuit, all laid on different metallic layers. The metallic layers together with the supporting substrates are vertically stacked up to save the circuit dimension. The LPF and HPF used in the diplexer structure are designed by a quasi-lumped approach, which the LC lumped-elements circuit models are developed to analyze filters' characteristics and to emulate their frequency responses. Half-wavelength resonating slots are employed in the diplexer's structure to increase the isolation between its two signal diverting ports. Experiments are conducted to verify the multilayer dual-band BPF and the diplexer design. Agreements are observed between the simulation and the measurement.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
The SSL R&D Plan provides analysis and direction for ongoing R&D activities to advance SSL technology and increase energy savings. The R&D Plan also reviews SSL technology status and trends for both LEDs and OLEDs and offers an overview of the current DOE SSL R&D project portfolio.
SSL: A software specification language
NASA Technical Reports Server (NTRS)
Austin, S. L.; Buckles, B. P.; Ryan, J. P.
1976-01-01
SSL (Software Specification Language) is a new formalism for the definition of specifications for software systems. The language provides a linear format for the representation of the information normally displayed in a two-dimensional module inter-dependency diagram. In comparing SSL to FORTRAN or ALGOL, it is found to be largely complementary to the algorithmic (procedural) languages. SSL is capable of representing explicitly module interconnections and global data flow, information which is deeply imbedded in the algorithmic languages. On the other hand, SSL is not designed to depict the control flow within modules. The SSL level of software design explicitly depicts intermodule data flow as a functional specification.
[Study on the hepatocytic cell targetability of liposomes].
Hou, Xin-pu; Wang, Li; Wang, Xiang-tao; Li, Sha
2003-02-01
To target for hepatocytic cell, liposomes was modified by special ligand. Sterically stabilized liposomes (SSL) was conjugated with asialofeticin (AF), the ligand of asialoglycoprotein receptor (ASGP-R) of hepatocyte. ASGP-R-BLM is the ASGP-R reconstructed on bilayer lipid membrane (BLM). The recognition reaction between AF-SSL and ASGP-R-BLM can be monitored by the varieties of membrane electrical parameters. The targetability of AF-SSL mediated to hepatocyte was detected by radioisotopic labeled in vitro and in vivo. The therapeutic effect of antihepatocarcinoma was observed also. The lifetime of ASGP-R-BLM decreased with the added amount of AF-SSL. It was demonstrated that there was recognition reaction between AF-SSL and ASGP-R-BLM. The combination of AF-SSL with hepatocyte was significantly higher than that of SSL without AF-modified in vitro and in vivo. The survival time of rat for AF-SSL carriered ADM (adriamycin) group was much longer and the toxicities on heart, kidney and lung were lower than those SSL carried ADM group. It is possible to actively target the cell with specific receptor by ligand modified liposomes. The result prvide scientific basis of hepatocyte targeted liposomes.
Accountability for Information Flow via Explicit Formal Proof
2009-10-01
macrobenchmarks. The first (called OpenSSL in the table below), unpacks the OpenSSL source code, compiles it and deletes it. The other (called Fuse in...penalty for PCFS as compared to Fuse/Null is approximately 10% for OpenSSL , and 2.5% for Fuse. The difference arises because the OpenSSL benchmark depends...Macrobenchmarks Benchmark PCFS Fuse/Null Ext3 OpenSSL 126 114 94 Fuse x 5 79 77 70 15 In summary, assuming a low rate of cache misses, the
In sunscreen lotion (SSL) formulations, titanium dioxide (nTiO2) nanoparticles are coated with an Al(OH)3 layer to shield against the harmful effects of hydroxyl radicals (•OH), superoxide anion radicals (O2-•), and other reactive oxyge...
A study of internet of things real-time data updating based on WebSocket
NASA Astrophysics Data System (ADS)
Wei, Shoulin; Yu, Konglin; Dai, Wei; Liang, Bo; Zhang, Xiaoli
2015-12-01
The Internet of Things (IoT) is gradually entering the industrial stage. Web applications in IoT such as monitoring, instant messaging, real-time quote system changes need to be transmitted in real-time mode to client without client constantly refreshing and sending the request. These applications often need to be as fast as possible and provide nearly real-time components. Real-time data updating is becoming the core part of application layer visualization technology in IoT. With support of data push in server-side, running state of "Things" in IoT could be displayed in real-time mode. This paper discusses several current real-time data updating method and explores the advantages and disadvantages of each method. We explore the use of WebSocket in a new approach for real-time data updating in IoT, since WebSocket provides low delay, low network throughput solutions for full-duplex communication.
ERIC Educational Resources Information Center
Schein, Jerome D.
1995-01-01
Spanish Sign Language (SSL) is now the second most used sign language. This article introduces resources for the study of SSL, including three SSL dictionaries--two from Argentina and one from Puerto Rico. Differences in SSL between and within the two countries are noted. Implications for deaf educators in North America are drawn. (Author/DB)
ERIC Educational Resources Information Center
Montgomery County Public Schools, 2014
2014-01-01
Student Service Learning (SSL) provides students the opportunity to actively participate in the community and build the skills they need to be successful students and citizens. This booklet provides information about the Maryland State Department of Education SSL graduation mandate. Completing 75 SSL hours is a requirement for high school…
Dissipation processes in the Tongue of the Ocean
NASA Astrophysics Data System (ADS)
Hooper V, James A.; Baringer, Molly O.; St. Laurent, Louis C.; Dewar, William K.; Nowacek, Doug
2016-05-01
The Tongue of the Ocean (TOTO) region located within the Bahamas archipelago is a relatively understudied region in terms of both its biological and physical oceanographic characteristics. A prey-field mapping cruise took place in the fall between 15 September 2008 and 1 October 2008, consisting of a series of transects and "clovers" to study the spatial and temporal variability. The region is characterized by a deep scattering layer (DSL), which is preyed on by nekton that serves as the food for beaked whale and other whale species. This study marks the first of its kind where concurrent measurements of acoustic backscatter and turbulence have been conducted for a nekton scattering layer well below the euphotic zone. Turbulence data collected from a Deep Microstructure Profiler are compared to biological and shear data collected by a 38 kHz Simrad EK 60 echo sounder and a hydrographic Doppler sonar system, respectively. From these measurements, the primary processes responsible for the turbulent production in the TOTO region are assessed. The DSL around 500 m and a surface scattering layer (SSL) are investigated for raised ɛ values. Strong correlation between turbulence levels and scattering intensity of prey is generally found in the SSL with dissipation levels as large as ˜10-7 W kg-1, 3 orders of magnitude above background levels. In the DSL and during the diel vertical migration, dissipation levels ˜10-8 W kg-1 were observed.
Manufacturing Process for OLED Integrated Substrate
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hung, Cheng-Hung; McCamy, James; Ashtosh, Ganjoo
2017-01-27
The primary objective of this project is to demonstrate manufacturing processes for technologies that will enable commercialization of a large-area and low-cost “integrated substrate” product for rigid OLED SSL lighting. The integrated substrate product will consist of a low cost, float glass substrate combined with a transparent conductive anode film layer, and light out-coupling (internal and external extraction layers) structures. In combination, these design elements will enable an integrated substrate meeting or exceeding 2015 performance targets for cost ($60/m2), extraction efficiency (50%) and sheet resistance (<10 ohm/sq).
Reliability of solid-state lighting electrical drivers subjected to WHTOL accelerated aging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lall, Pradeep; Sakalauku, Peter; Davis, Lynn
An investigation of a solid-state lighting (SSL) luminaire with the focus on the electronic driver which has been exposed to a standard wet hot temperature operating life (WHTOL) of 85% RH and 85°C in order to assess reliability of prolonged exposer to a harsh environment has been conducted. SSL luminaires are beginning introduced as head lamps in some of today's luxury automobiles and may also be fulfilling a variety of important outdoor applications such as overhead street lamps, traffic signals and landscape lighting. SSL luminaires in these environments are almost certain to encounter excessive moisture from humidity and high temperaturesmore » for a persistent period of time. The lack of accelerated test methods for LEDs to assess long-term reliability prior to introduction into the marketplace, a need for SSL physics based PHM modeling indicators for assessment and prediction of LED life, as well as the U.S. Department of Energy's R&D roadmap to replace todays lighting with SSL luminaires makes it important to increase the understanding of the reliability of SSL devices, specifically, in harsh environment applications. In this work, a set of SSL electrical drivers were investigated to determine failure mechanisms that occur during prolonged harsh environment applications. Each driver consists of four aluminum electrolytic capacitors (AECs) of three different types and was considered the weakest component inside the SSL electrical driver. The reliability of the electrical driver was assessed by monitoring the change in capacitance and the change in equivalent series resistance for each AEC, as well as monitoring the luminous flux of the SSL luminaire or the output of the electrical driver. The luminous flux of a pristine SSL electrical driver was also monitored in order to detect minute changes in the electrical drivers output and to aid in the investigation of the SSL luminaires reliability. The failure mechanisms of the electrical drivers have been determined and are presented in this paper.« less
Structural basis for inhibition of TLR2 by staphylococcal superantigen-like protein 3 (SSL3)
Koymans, Kirsten J.; Feitsma, Louris J.; Brondijk, T. Harma C.; Aerts, Piet C.; Lukkien, Eddie; Lössl, Philip; van Kessel, Kok P. M.; de Haas, Carla J. C.; van Strijp, Jos A. G.; Huizinga, Eric G.
2015-01-01
Toll-like receptors (TLRs) are crucial in innate recognition of invading micro-organisms and their subsequent clearance. Bacteria are not passive bystanders and have evolved complex evasion mechanisms. Staphylococcus aureus secretes a potent TLR2 antagonist, staphylococcal superantigen-like protein 3 (SSL3), which prevents receptor stimulation by pathogen-associated lipopeptides. Here, we present crystal structures of SSL3 and its complex with TLR2. The structure reveals that formation of the specific inhibitory complex is predominantly mediated by hydrophobic contacts between SSL3 and TLR2 and does not involve interaction of TLR2–glycans with the conserved LewisX binding site of SSL3. In the complex, SSL3 partially covers the entrance to the lipopeptide binding pocket in TLR2, reducing its size by ∼50%. We show that this is sufficient to inhibit binding of agonist Pam2CSK4 effectively, yet allows SSL3 to bind to an already formed TLR2–Pam2CSK4 complex. The binding site of SSL3 overlaps those of TLR2 dimerization partners TLR1 and TLR6 extensively. Combined, our data reveal a robust dual mechanism in which SSL3 interferes with TLR2 activation at two stages: by binding to TLR2, it blocks ligand binding and thus inhibits activation. Second, by interacting with an already formed TLR2–lipopeptide complex, it prevents TLR heterodimerization and downstream signaling. PMID:26283364
Functional basis for complement evasion by staphylococcal superantigen-like 7.
Bestebroer, Jovanka; Aerts, Piet C; Rooijakkers, Suzan H M; Pandey, Manoj K; Köhl, Jörg; van Strijp, Jos A G; de Haas, Carla J C
2010-10-01
The human pathogen Staphylococcus aureus has a plethora of virulence factors that promote its colonization and survival in the host. Among such immune modulators are staphylococcal superantigen-like (SSL) proteins, comprising a family of 14 small, secreted molecules that seem to interfere with the host innate immune system. SSL7 has been described to bind immunoglobulin A (IgA) and complement C5, thereby inhibiting IgA-FcαRI binding and serum killing of Escherichia coli. As C5a generation, in contrast to C5b-9-mediated lysis, is crucial for immune defence against staphylococci, we investigated the impact of SSL7 on staphylococcal-induced C5a-mediated effects. Here, we show that SSL7 inhibits C5a generation induced by staphylococcal opsonization, slightly enhanced by its IgA-binding capacity. Moreover, we demonstrate a strong protective activity of SSL7 against staphylococcal clearance in human whole blood. SSL7 strongly inhibited the C5a-induced phagocytosis of S. aureus and oxidative burst in an in vitro whole-blood inflammation model. Furthermore, we found that SSL7 affects all three pathways of complement activation and inhibits the cleavage of C5 by interference of its binding to C5 convertases. Finally, SSL7 effects were also demonstrated in vivo. In a murine model of immune complex peritonitis, SSL7 abrogated the C5a-driven influx of neutrophils in mouse peritoneum. © 2010 Blackwell Publishing Ltd.
Functional basis for complement evasion by staphylococcal superantigen-like 7
Bestebroer, Jovanka; Aerts, Piet C.; Rooijakkers, Suzan H.M.; Pandey, Manoj K.; Köhl, Jörg; van Strijp, Jos A. G.; de Haas, Carla J. C.
2010-01-01
Summary The human pathogen Staphylococcus aureus has a plethora of virulence factors that promote its colonization and survival in the host. Among such immune modulators are staphylococcal superantigen-like (SSL) proteins, comprising a family of 14 small, secreted molecules that seem to interfere with the host innate immune system. SSL7 has been described to bind immunoglobulin A (IgA) and complement C5, thereby inhibiting IgA-FcαRI binding and serum killing of E. coli. As C5a generation, in contrast to C5b-9-mediated lysis, is crucial for immune defense against staphylococci, we investigated the impact of SSL7 on staphylococcal-induced C5a-mediated effects. Here, we show that SSL7 inhibits C5a generation induced by staphylococcal opsonization, slightly enhanced by its IgA-binding capacity. Moreover, we demonstrate a strong protective activity of SSL7 against staphylococcal clearance in human whole blood. SSL7 strongly inhibited the C5a-induced phagocytosis of S. aureus and oxidative burst in an in vitro whole blood inflammation model. Furthermore, we found that SSL7 affects all three pathways of complement activation and inhibits the cleavage of C5 by interference of its binding to C5 convertases. Finally, SSL7 effects were also demonstrated in vivo. In a murine model of immune complex peritonitis, SSL7 abrogated the C5a-driven influx of neutrophils in mouse peritoneum. PMID:20545943
Becker, Sara J; Squires, Daniel D; Strong, David R; Barnett, Nancy P; Monti, Peter M; Petry, Nancy M
2016-01-01
Few prospective studies have evaluated theory-driven approaches to the implementation of evidence-based opioid treatment. This study compared the effectiveness of an implementation model (Science to Service Laboratory; SSL) to training as usual (TAU) in promoting the adoption of contingency management across a multisite opioid addiction treatment program. We also examined whether the SSL affected putative mediators of contingency management adoption (perceived innovation characteristics and organizational readiness to change). Sixty treatment providers (39 SSL, 21 TAU) from 15 geographically diverse satellite clinics (7 SSL, 8 TAU) participated in the 12-month study. Both conditions received didactic contingency management training and those in the predetermined experimental region received 9 months of SSL-enhanced training. Contingency management adoption was monitored biweekly, whereas putative mediators were measured at baseline, 3 months, and 12 months. Relative to providers in the TAU region, treatment providers in the SSL region had comparable likelihood of contingency management adoption in the first 20 weeks of the study, and then significantly higher likelihood of adoption (odds ratios = 2.4-13.5) for the remainder of the study. SSL providers also reported higher levels of one perceived innovation characteristic (Observability) and one aspect of organizational readiness to change (Adequacy of Training Resources), although there was no evidence that the SSL affected these putative mediators over time. Results of this study indicate that a fully powered randomized trial of the SSL is warranted. Considerations for a future evaluation are discussed.
NASA Astrophysics Data System (ADS)
Choe, Byeong-In; Park, Byung-Gook; Lee, Jong-Ho
2013-06-01
The program disturbance characteristic in the three-dimensional (3D) stack NAND flash was analyzed for the first time in terms of string select line (SSL) threshold voltage (Vth) and p-type body doping profile. From the edge word line (W/L) program disturbance, we can observe the boosted channel potential loss as a function of SSL Vth and body doping profile for SSL device. According to simulation work, a high Vth of the SSL device is required to suppress channel leakage during programming. When the body doping of the SSL device is high in the channel, there is a large band bending near the gate edge of the SSL adjacent to the edge W/L cell of boosted cell strings, which generates significantly electron-hole pairs. The generated electrons decreases the boosted channel potential, resulting in increase of program disturbance of the inhibit strings. Through optimization of the body doping profile of the SSL device, both channel leakage and the program disturbance are successfully suppressed for a highly reliable 3D stack NAND flash memory cell operation.
Fishburn, James; Tomko, Eric; Galburt, Eric; Hahn, Steven
2015-03-31
Formation of the RNA polymerase II (Pol II) open complex (OC) requires DNA unwinding mediated by the transcription factor TFIIH helicase-related subunit XPB/Ssl2. Because XPB/Ssl2 binds DNA downstream from the location of DNA unwinding, it cannot function using a conventional helicase mechanism. Here we show that yeast TFIIH contains an Ssl2-dependent double-stranded DNA translocase activity. Ssl2 tracks along one DNA strand in the 5' → 3' direction, implying it uses the nontemplate promoter strand to reel downstream DNA into the Pol II cleft, creating torsional strain and leading to DNA unwinding. Analysis of the Ssl2 and DNA-dependent ATPase activity of TFIIH suggests that Ssl2 has a processivity of approximately one DNA turn, consistent with the length of DNA unwound during transcription initiation. Our results can explain why maintaining the OC requires continuous ATP hydrolysis and the function of TFIIH in promoter escape. Our results also suggest that XPB/Ssl2 uses this translocase mechanism during DNA repair rather than physically wedging open damaged DNA.
Kim, J-E; Roh, E; Lee, M H; Yu, D H; Kim, D J; Lim, T-G; Jung, S K; Peng, C; Cho, Y-Y; Dickinson, S; Alberts, D; Bowden, G T; Einspahr, J; Stratton, S P; Curiel-Lewandrowski, C; Bode, A M; Lee, K W; Dong, Z
2016-08-04
Solar ultraviolet (UV) light is a major etiological factor in skin carcinogenesis, with solar UV-stimulated signal transduction inducing pathological changes and skin damage. The primary sensor of solar UV-induced cellular signaling has not been identified. We use an experimental system of solar simulated light (SSL) to mimic solar UV and we demonstrate that Fyn is a primary redox sensor involved in SSL-induced signal transduction. Reactive oxygen species (ROS) generated by SSL exposure directly oxidize Cys488 of Fyn, resulting in increased Fyn kinase activity. Fyn oxidation was increased in mouse skin after SSL exposure and Fyn-knockout mice formed larger and more tumors compared with Fyn wild-type mice when exposed to SSL for an extended period of time. Murine embryonic fibroblasts (MEFs) lacking Fyn and cells in which Fyn expression was knocked down were resistant to SSL-induced apoptosis. Furthermore, cells expressing mutant Fyn (C448A) were resistant to SSL-induced apoptosis. These findings suggest that Fyn acts as a regulatory nexus between solar UV, ROS and signal transduction during skin carcinogenesis.
Assessing the evidence of Six Sigma and Lean in the health care industry.
DelliFraine, Jami L; Langabeer, James R; Nembhard, Ingrid M
2010-01-01
Popular quality improvement tools such as Six Sigma and Lean Systems (SS/L) claim to provide health care managers the opportunity to improve health care quality on the basis of sound methodology and data. However, it is unclear whether these 2 quality improvement tools actually improve health care quality. The authors conducted a comprehensive literature review to assess the empirical evidence relating SS/L to improved clinical outcomes, processes of care, and financial performance of health care organizations. The authors identified 177 articles on SS/L published in the last 10 years. However, only 34 of them reported any outcomes of the SS/L projects studied, and less than one-third of these articles included statistical analyses to test for significant changes in outcomes. This review demonstrates that there are significant gaps in the SS/L health care quality improvement literature and very weak evidence that SS/L improve health care quality.
Becker, Sara J.; Squires, Daniel D.; Strong, David R.; Barnett, Nancy P.; Monti, Peter M.; Petry, Nancy M.
2016-01-01
Background Few prospective studies have evaluated theory-driven approaches to the implementation of evidence-based opioid treatment. This study compared the effectiveness of an implementation model (Science to Service Laboratory; SSL) to training as usual (TAU) in promoting the adoption of contingency management across a multi-site opiate addiction treatment program. We also examined whether the SSL affected putative mediators of contingency management adoption (perceived innovation characteristics and organizational readiness to change). Methods Sixty treatment providers (39 SSL, 21 TAU) from 15 geographically diverse satellite clinics (7 SSL, 8 TAU) participated in the 12-month study. Both conditions received didactic contingency management training and those in the pre-determined experimental region received 9 months of SSL-enhanced training. Contingency management adoption was monitored biweekly, while putative mediators were measured at baseline, 3-, and 12-months. Results Relative to providers in the TAU region, treatment providers in the SSL region had comparable likelihood of contingency management adoption in the first 20 weeks of the study, and then significantly higher likelihood of adoption (odds ratios = 2.4-13.5) for the remainder of the study. SSL providers also reported higher levels of one perceived innovation characteristic (Observability) and one aspect of organizational readiness to change (Adequacy of Training Resources), although there was no evidence that the SSL affected these putative mediators over time. Conclusions Results of this study indicate that a fully powered randomized trial of the SSL is warranted. Considerations for a future evaluation are discussed. PMID:26682582
Bajwa, Paramjit K; Ho, Chi-Yip; Chan, Chi-Kin; Martin, Vincent J J; Trevors, Jack T; Lee, Hung
2013-06-01
Global gene expression was analyzed in Saccharomyces cerevisiae T2 cells grown in the presence of hardwood spent sulphite liquor (HW SSL) and each of the three main inhibitors in HW SSL, acetic acid, hydroxymethyfurfural (HMF) and furfural, using a S. cerevisiae DNA oligonucleotide microarray. The objective was to compare the gene expression profiles of T2 cells in response to the individual inhibitors against that elicited in response to HW SSL. Acetic acid mainly affected the expression of genes related to the uptake systems of the yeast as well as energy generation and metabolism. Furfural and HMF mainly affected the transcription of genes involved in the redox balance of the cell. On the other hand, the effect of HW SSL on S. cerevisiae T2 cells was distinct and considerably more diverse as compared to the effect of individual inhibitors found in lignocellulosic hydrolysates. This is not surprising as HW SSL contains a complex mixture of inhibitors which may act synergistically. HW SSL elicited significant changes in expression of genes involved in diverse and multiple effects on several aspects of the cellular structure and function. A notable response to HW SSL was decreased expression of the ribosomal protein genes in T2 cells. In addition, HW SSL decreased the expression of genes functioning in the synthesis and transport of proteins as well as metabolism of carbohydrates, lipids, vitamins and vacuolar proteins. Furthermore, the expression of genes involved in multidrug resistance, iron transport and pheromone response was increased, suggesting that T2 cells grown in the presence of HW SSL may have activated pheromone response and/or activated pleiotropic drug response. Some of the largest changes in gene expression were observed in the presence of HW SSL and the affected genes are involved in mating, iron transport, stress response and phospholipid metabolism. A total of 59 out of the 400 genes differentially expressed in the presence of HW SSL, acetic acid, HMF and furfural, belonged to the category of poorly characterized genes. The results indicate that transcriptional responses to individual lignocellulosic inhibitors gave a different picture and may not be representative of how the cells would respond to the presence of all the inhibitors in lignocellulosic hydrolysates such as HW SSL.
Ultra High p-doping Material Research for GaN Based Light Emitters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vladimir Dmitriev
2007-06-30
The main goal of the Project is to investigate doping mechanisms in p-type GaN and AlGaN and controllably fabricate ultra high doped p-GaN materials and epitaxial structures. Highly doped p-type GaN-based materials with low electrical resistivity and abrupt doping profiles are of great importance for efficient light emitters for solid state lighting (SSL) applications. Cost-effective hydride vapor phase epitaxial (HVPE) technology was proposed to investigate and develop p-GaN materials for SSL. High p-type doping is required to improve (i) carrier injection efficiency in light emitting p-n junctions that will result in increasing of light emitting efficiency, (ii) current spreading inmore » light emitting structures that will improve external quantum efficiency, and (iii) parameters of Ohmic contacts to reduce operating voltage and tolerate higher forward currents needed for the high output power operation of light emitters. Highly doped p-type GaN layers and AlGaN/GaN heterostructures with low electrical resistivity will lead to novel device and contact metallization designs for high-power high efficiency GaN-based light emitters. Overall, highly doped p-GaN is a key element to develop light emitting devices for the DOE SSL program. The project was focused on material research for highly doped p-type GaN materials and device structures for applications in high performance light emitters for general illumination P-GaN and p-AlGaN layers and multi-layer structures were grown by HVPE and investigated in terms of surface morphology and structure, doping concentrations and profiles, optical, electrical, and structural properties. Tasks of the project were successfully accomplished. Highly doped GaN materials with p-type conductivity were fabricated. As-grown GaN layers had concentration N{sub a}-N{sub d} as high as 3 x 10{sup 19} cm{sup -3}. Mechanisms of doping were investigated and results of material studies were reported at several International conferences providing better understanding of p-type GaN formation for Solid State Lighting community. Grown p-type GaN layers were used as substrates for blue and green InGaN-based LEDs made by HVPE technology at TDI. These results proved proposed technical approach and facilitate fabrication of highly conductive p-GaN materials by low-cost HVPE technology for solid state lighting applications. TDI has started the commercialization of p-GaN epitaxial materials.« less
Light quality and efficiency of consumer grade solid state lighting products
NASA Astrophysics Data System (ADS)
Dam-Hansen, Carsten; Corell, Dennis Dan; Thorseth, Anders; Poulsen, Peter Behrensdorff
2013-03-01
The rapid development in flux and efficiency of Light Emitting Diodes (LED) has resulted in a flooding of the lighting market with Solid State Lighting (SSL) products. Many traditional light sources can advantageously be replaced by SSL products. There are, however, large variations in the quality of these products, and some are not better than the ones they are supposed to replace. A lack of quality demands and standards makes it difficult for consumers to get an overview of the SSL products. Here the results of a two year study investigating SSL products on the Danish market are presented. Focus has been on SSL products for replacement of incandescent lamps and halogen spotlights. The warm white light and good color rendering properties of these traditional light sources are a must for lighting in Denmark and the Nordic countries. 266 SSL replacement lamps have been tested for efficiency and light quality with respect to correlated color temperature and color rendering properties. This shows a trade-off between high color rendering warm white light and energy efficiency. The lumen and color maintenance over time has been investigated and results for products running over 11000 h will be presented. A new internet based SSL product selection tool will be shown. Here the products can be compared on efficiency, light quality parameters, thus providing a better basis for the selection of SSL products for consumers.
Solid-State Lighting R&D Plan - 2015
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bardsley, Norman; Bland, Stephen; Hansen, Monica
2015-05-28
Provides analysis and direction for ongoing R&D activities to advance SSL technology and increase energy savings, reviewing SSL technology status and trends for both LEDs and OLEDs and offering an overview of the current DOE SSL R&D project portfolio.
Spiribacter roseus sp. nov., a moderately halophilic species of the genus Spiribacter from salterns.
León, María José; Vera-Gargallo, Blanca; Sánchez-Porro, Cristina; Ventosa, Antonio
2016-10-01
Four pink-pigmented, non-motile, Gram-staining-negative and moderately halophilic curved rods, designated strains SSL50T, SSL25, SSL97 and SSL4, were isolated from a saltern located in Isla Cristina, Huelva, south-west Spain. Phylogenetic analyses based on 16S rRNA gene sequences showed that they were members of the genus Spiribacter, most closely related to Spiribacter curvatus UAH-SP71T (99.3-99.5 % sequence similarity) and Spiribacter salinus M19-40T (96.5-96.7 %). Other related strains were Alkalilimnicola ehrlichii MLHE-1T (95.1-95.3 %), Arhodomonas recens RS91T (95.1-95.2 %) and Arhodomonas aquaeolei ATCC 49307T (95.0-95.1 %), all members of the family Ectothiorhodospiraceae. The major fatty acids were C18 : 1ω6c and/or C18 : 1ω7c, C16 : 0 and C12 : 0. The DNA G+C range was 64.0-66.3 mol%. The DNA-DNA hybridization values between strains SSL50T, SSL25, SSL97, SSL4 and S. piribacter. curvatus UAH-SP71T were 37-49 %. The average nucleotide identity (ANIb) values between the genome of strain SSL50T and those of the two other representatives of the genus Spiribacter, S. curvatus UAH-SP71T and S. salinus M19-40T, were 82.4 % and 79.1 %, respectively, supporting the proposal of a novel species of the genus Spiribacter. On the basis of the polyphasic analysis, the four new isolates are considered to represent a novel species of the genus Spiribacter, for which the name Spiribacter roseus sp. nov. is proposed. The type strain is SSL50T (=CECT 9117T=IBRC-M 11076T).
Initiated Protocol Telephony Feasibility for the US Navy, Embedded Proof-of-Concept
2011-03-01
2.1 Generating Certificates Using Open SSL 1. OpenSSL can be used to generate certificates. There are a number of helper scripts written in Perl that...help with the creation and maintenance of the certificate and keys. OpenSSL is available from a number of sites, i.e., slproweb.com. The default...installation is adequate although it may be useful to add the OpenSSL \\bin directory to the system environment variable PATH. Perl is also available
NASA Astrophysics Data System (ADS)
Li, Qinghua; Yan, Zhiqiang; Li, Feng; Lu, Weiyue; Wang, Jiyao; Guo, Chuanyong
2012-07-01
No satisfactory anti-fibrotic therapies have yet been applied clinically. One of the main reasons is the inability to specifically target the responsible cells to produce an available drug concentration and the side-effects. Exploiting the key role of the activated hepatic stellate cells (HSCs) in both hepatic fibrogenesis and over-expression of platelet-derived growth factor receptor-β (PDGFR-β), we constructed targeted sterically stable liposomes (SSLs) modified by a cyclic peptide (pPB) with affinity for the PDGFR-β to deliver interferon (IFN)-γ to HSCs. The pPB-SSL-IFN-γ showed satisfactory size distribution. In vitro pPB-SSL could be taken up by activated HSCs. The study of tissue distribution via living-body animal imaging showed that the pPB-SSL-IFN-γ mostly accumulated in the liver until 24 h. Furthermore, the pPB-SSL-IFN-γ showed more significant remission of hepatic fibrosis. In vivo the histological Ishak stage, the semiquantitative score for collagen in fibrotic liver and the serum levels of collagen type IV-C in fibrotic rats treated with pPB-SSL-IFN-γ were less than those treated with SSL-IFN-γ, IFN-γ and the control group. In vitro pPB-SSL-IFN-γ was also more effective in suppressing activated HSC proliferation and inducing apoptosis of activated HSCs. Thus the data suggest that pPB-SSL-IFN-γ might be a more effective anti-fibrotic agent and a new opportunity for clinical therapy of hepatic fibrosis.
Peña, Aránzazu; Mingorance, Mª Dolores; Guzmán-Carrizosa, Ignacio; Fernández-Espinosa, Antonio J
2015-03-01
We assessed the effects of applying stabilized sewage sludge (SSL) and composted sewage sludge (CLV), at 5 and 10% to an acid mining soil. Limed soil (NCL) amended or not with SSL and CLV was incubated for 47 days. We studied the cations and organic and inorganic anions in the soil solution by means of ion chromatography. Liming led to big increases in Ca(2+) and SO4(2-) and to significant decreases in K(+), Mg(2+), NH4(+) and NO3(-). Addition of both organic amendments increased some cations (NH4(+), K(+), Mg(2+), Na(+)) and anions (Cl(-), NO3(-) only with CLV and PO4(3-) only with SSL) and provided a greater amount of low-molecular-weight organic acids (LMWOAs) (SSL more than CLV). Incubation led to decreases in all cations, particularly remarkable for Ca(2+) and Mg(2+) in SSL-10. A decrease in NH4(+) was associated with variations in NO2(-) and NO3(-) resulting from nitrification reactions. During incubation the LMWOAs content tended to decrease similarly to the cations, especially in SSL-10. Chemometric tools revealed a clear discrimination between SSL, CLV and NCL. Furthermore, treatment effects depended upon dose, mainly in SSL. Amendment nature and dose affect the quality of a mining soil and improve conditions for plant establishment. Copyright © 2014 Elsevier Ltd. All rights reserved.
Functional genomics identifies specific vulnerabilities in PTEN-deficient breast cancer.
Tang, Yew Chung; Ho, Szu-Chi; Tan, Elisabeth; Ng, Alvin Wei Tian; McPherson, John R; Goh, Germaine Yen Lin; Teh, Bin Tean; Bard, Frederic; Rozen, Steven G
2018-03-22
Phosphatase and tensin homolog (PTEN) is one of the most frequently inactivated tumor suppressors in breast cancer. While PTEN itself is not considered a druggable target, PTEN synthetic-sick or synthetic-lethal (PTEN-SSL) genes are potential drug targets in PTEN-deficient breast cancers. Therefore, with the aim of identifying potential targets for precision breast cancer therapy, we sought to discover PTEN-SSL genes present in a broad spectrum of breast cancers. To discover broad-spectrum PTEN-SSL genes in breast cancer, we used a multi-step approach that started with (1) a genome-wide short interfering RNA (siRNA) screen of ~ 21,000 genes in a pair of isogenic human mammary epithelial cell lines, followed by (2) a short hairpin RNA (shRNA) screen of ~ 1200 genes focused on hits from the first screen in a panel of 11 breast cancer cell lines; we then determined reproducibility of hits by (3) identification of overlaps between our results and reanalyzed data from 3 independent gene-essentiality screens, and finally, for selected candidate PTEN-SSL genes we (4) confirmed PTEN-SSL activity using either drug sensitivity experiments in a panel of 19 cell lines or mutual exclusivity analysis of publicly available pan-cancer somatic mutation data. The screens (steps 1 and 2) and the reproducibility analysis (step 3) identified six candidate broad-spectrum PTEN-SSL genes (PIK3CB, ADAMTS20, AP1M2, HMMR, STK11, and NUAK1). PIK3CB was previously identified as PTEN-SSL, while the other five genes represent novel PTEN-SSL candidates. Confirmation studies (step 4) provided additional evidence that NUAK1 and STK11 have PTEN-SSL patterns of activity. Consistent with PTEN-SSL status, inhibition of the NUAK1 protein kinase by the small molecule drug HTH-01-015 selectively impaired viability in multiple PTEN-deficient breast cancer cell lines, while mutations affecting STK11 and PTEN were largely mutually exclusive across large pan-cancer data sets. Six genes showed PTEN-SSL patterns of activity in a large proportion of PTEN-deficient breast cancer cell lines and are potential specific vulnerabilities in PTEN-deficient breast cancer. Furthermore, the NUAK1 PTEN-SSL vulnerability identified by RNA interference techniques can be recapitulated and exploited using the small molecule kinase inhibitor HTH-01-015. Thus, NUAK1 inhibition may be an effective strategy for precision treatment of PTEN-deficient breast tumors.
Abdelhamid, Alaa; Omran, Mostafa; Bakhshalian, Neema; Tarnow, Dennis; Zadeh, Homayoun H
2016-06-01
The aims of this study were (i) to evaluate the efficacy of ridge preservation and repair procedures involving the application of SocketKAP(™) and SocketKAGE(™) devices following tooth removal and (ii) to evaluate alveolar bone volumetric changes at 6 months post-extraction in intact sockets or those with facial wall dehiscence defects using 3-dimensional pre- and postoperative CBCT data. Thirty-six patients required 61 teeth extracted. Five cohorts were established: Group A: Intact Socket Negative Control Group B: Intact Socket + SocketKAP(™) Group C: Intact Socket Filled with Anorganic Bovine Bone Mineral (ABBM) + SocketKAP(™) Group D: Facial Dehiscence Socket Negative Control Group E: Facial Dehiscence Socket Filled with ABBM + SocketKAP(™) + SocketKAGE(™) . Preoperative CBCT scans were obtained followed by digital subtraction of the test teeth. At 6 months post-extraction, another CBCT scan was obtained. The pre- and postoperative scans were then superimposed, allowing highly accurate quantitative determination of the 3D volumetric alveolar bone volume changes from baseline through 6 months. Significant volumetric bone loss occurred in all sockets, localized mainly in the 0-3 mm zone apical to the ridge crest. For intact sockets, SocketKAP(™) + ABBM treatment led to a statistically significant greater percentage of remaining mineralized tissue volume when compared to negative control group. A significant difference favoring SocketKAP(™) + SocketKAGE(™) + ABBM treatment was observed for sockets with facial dehiscence defects compared to the negative control group. SocketKAP(™) , with ABBM, appears effective in limiting post-extraction volumetric bone loss in intact sockets, while SocketKAP(™) + SocketKAGE + ABBM appears effective in limiting post-extraction bone loss in sockets with dehiscence defects. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Locking Down the Software Development Environment
2014-12-01
OpenSSL code [13]. The OpenSSL software is, as the name implies, open source, a result of many developers coding beginning in 1998 using the C...programming language to build crypto services. OpenSSL is used widely both on the Internet and in firmware [13], further delaying the ability of many
Janjua, Huma Gul Rehana; Høgdall, Estrid; Linnemann, Dorte
2015-04-01
Hyperplastic polyps (HP) of the colon and rectum were previously considered benign. Newer studies have suggested that colorectal HP are different entities. The aim of this study was to reclassify lesions from a 5-year period previously classified as colorectal HP into traditional hyperplastic polyp (THP), sessile serrated lesions (SSL), and other lesions. All patients were confirmed in the Danish National Pathology Database for the occurrence of metachronous polyps/adenomas, colorectal cancer (CRC), and other gastrointestinal malignancies. Molecular pathology of the CRC were characterized and correlated with the index lesion. In total, 591 HP biopsy specimens were obtained from 480 patients. The lesions were reclassified as: 358 THP, 109 SSL, 35 TA, 81 unspecified non-neoplastic lesions, four traditional serrated adenoma, and 4 SSL with cytological dysplasia. Seven patients developed CRC in the follow-up period (1 patient had SSL, 4 had THP, and 2 had unspecified non-neoplastic lesions). Ten patients developed other gastrointestinal malignancies. The patient with SSL as index lesions who developed CRC harbored V600E BRAF mutation in both index lesion and the carcinoma. Sixteen percent of patients with SSL subsequently developed a neoplastic lesion. Further studies are needed to clarify the cancer risk of SSL. © 2015 APMIS. Published by John Wiley & Sons Ltd.
Abd Razak, Nasrul A; Abu Osman, Noor A; Ali, Sadeeq A; Gholizadeh, Hossein
2016-01-15
While considering how important the interface between the amputees with the prostheses socket, we have carried out research to compare the gradient pressure occur at the interface socket that may lead to the discomforting effects to the user using common ICRC polypropylene socket and air splint socket. Not Applicable SETTING: Not Applicable POPULATION: The subject was a 23 year old who suffered a traumatic defect on the right arm caused by higher electrical volt. F-Socket sensors have been used to measure dynamic socket interface pressure for the transradial amputee wearer during static and dynamic movements. The printed circuit with a thickness of 0.18 mm is equipped between the socket and the surface of the residual limb. Two F-Socket sensor is required to cover the entire socket surface attached to the residual limb. The average of 10 trials made on prosthetic user using both type of sockets for static and dynamic movements was recorded. The pressure gradient shows that the circumference of the socket interface for the ICRC polypropylene socket gives the most pressure distributions to the amputees compared to the pressure gradient for the air splint socket. The pressure gradient for ICRC socket increased consistently when the user makes movements while for the air splint socket remain constantly. The specific interface pressure occur at the socket interface help in determine the comfort and pain of the socket design and improve the correlation between the user and the prosthesis.
Resnik, Linda; Patel, Tarpit; Cooney, Shane G; Crisco, Joseph J; Fantini, Christopher
2016-01-01
This case study compares the impact of two prosthetic socket designs, a "traditional" transhumeral (TH) socket design and a Compression Released Stabilized (CRS) socket. A CRS socket was compared to the existing socket of two persons with transhumeral amputation. Comparisons included assessments of patient comfort and satisfaction with fit, as well as dynamic kinematic assessment using a novel high-speed, high-resolution, bi-plane video radiography system (XROMM, for X-ray Reconstruction of Moving Morphology). Subjects were more satisfied with the comfort of the traditional sockets, although they had positive impressions about aspects of the fit and style of the CRS socket, and thought that it provided better control. Dynamic kinematic assessment revealed that the CRS socket provided better control of the residual limb within the socket, and had less slippage as compared to a traditional TH socket design. The TH CRS socket provided better control of the residual limb within the socket, and had less slippage. However, participants were less satisfied with the comfort and overall utility of the CRS socket, and stated that additional fitting visits/modifications to the CRS socket were needed. It is possible that satisfaction with the CRS socket may have improved with prosthetic adjustment and more acclimation time. Implications for Rehabilitation A comfortable, good fitting prosthetic socket is the key factor in determining how long (or if) an upper limb amputee can tolerate wearing a prosthesis. This case series was a comparison of two socket designs, a 'traditional' socket design and a Compression Released Stabilized (CRS) socket design in persons with transhumeral amputation. The CRS socket provided better control of the residual limb within the socket, and had less slippage. However, its tightness made it more difficult to don. Both subjects were less satisfied with the comfort and overall utility of the CRS socket. However, satisfaction might have been improved with additional fitting visits and more acclimation time.
EDITORIAL: LED light sources (light for the future) LED light sources (light for the future)
NASA Astrophysics Data System (ADS)
Grandjean, N.
2010-09-01
Generating white light from electricity with maximum efficacy has been a long quest since the first incandescent lamp was invented by Edison at the end of the 19th century. Nowadays, semiconductors are making reality the holy grail of converting electrons into photons with 100% efficiency and with colours that can be mixed for white light illumination. The revolution in solid-state lighting (SSL) dates to 1994 when Nakamura reported the first high-brightness blue LED based on GaN semiconductors. Then, white light was produced by simply combining a blue dye with a yellow phosphor. After more than a decade of intensive research the performance of white LEDs is quite impressive, beating by far the luminous efficacy of compact fluorescent lamps. We are likely close to replacing our current lighting devices by SSL lamps. However, there are still technological and fabrication cost issues that could delay large market penetration of white LEDs. Interestingly, SSL may create novel ways of using light that could potentially limit electricity saving. Whatever the impact of SSL, it will be significant on our daily life. The purpose of this special cluster issue is to produce a snapshot of the current situation of SSL from different viewing angles. In an introductory paper, Tsao and co-workers from Sandia National Laboratories, present an energy-economics perspective of SSL considering societal changes and SSL technology evolution. In a second article, Narukawa et al working at Nichia Corporation—the pioneer and still the leading company in SSL—describe the state of the art of current research products. They demonstrate record performance with white LEDs exhibiting luminous efficacy of 183 lm W-1 at high-current injection. Then, a series of topical papers discuss in detail various aspects of the physics and technology of white LEDs Carrier localization in InGaN quantum wells has been considered the key to white LEDs' success despite the huge density of defects. A comprehensive review of the different localization mechanisms and their implication for internal quantum efficiency (IQE) is proposed by Oliver and co-workers from Cambridge University. When discussing IQE in InGaN-based LEDs, the efficiency droop at high-current injection always emerges, which is a major concern for the future of SSL technology. Here, a collaborative work between Samsung and the Gwangju Institute of Science and Technology (Korea) proves that a specific design of the active region can limit this detrimental effect. Once the issue of the IQE is solved, one still has to let the photons out of the chip. Matioli and Weisbuch from the University of California at Santa Barbara introduce the use of photonic crystals (PhCs) to improve light extraction efficiency. They describe different approaches to overcoming the main limitation of LEDs when implementing surface PhCs. The technology of SSL, and in particular of colour rendering, is tackled by Zukauskas et al who studied in detail different white light sources. They show that extreme colour-fidelity indices need to cover the entire spectrum, with a broad-band at 530-610 nm and a component beyond 610 nm. Then, the reliability of GaN-based LEDs is discussed in the paper of Meneghesso and co-workers. The authors consider the most important physical mechanisms that are (i) the degradation of the active layer of LEDs, (ii) the degradation of the package/phosphor system, (iii) the failure of GaN-based LEDs against electrostatic discharge. Finally, GaN LEDs on silicon developed in the group of Egawa at the Nagoya Institute of Technology are presented. This technology could allow a significant decrease in the fabrication cost of white LEDs.
SSL Demonstration: SSL Adoption by Museums: Survey Results, Analysis, and Recommendations
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
DOE Solid-State Lighting GATEWAY summary brief for special report on the results of a survey of the museum community regarding conversions to SSL in museums. Responses provided real-world insight into how LEDs are being incorporated into museums, and what successes and hurdles have been encountered in the process.
Achieving High Performance With TCP Over 40 GbE on NUMA Architectures for CMS Data Acquisition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bawej, Tomasz; et al.
2014-01-01
TCP and the socket abstraction have barely changed over the last two decades, but at the network layer there has been a giant leap from a few megabits to 100 gigabits in bandwidth. At the same time, CPU architectures have evolved into the multicore era and applications are expected to make full use of all available resources. Applications in the data acquisition domain based on the standard socket library running in a Non-Uniform Memory Access (NUMA) architecture are unable to reach full efficiency and scalability without the software being adequately aware about the IRQ (Interrupt Request), CPU and memory affinities.more » During the first long shutdown of LHC, the CMS DAQ system is going to be upgraded for operation from 2015 onwards and a new software component has been designed and developed in the CMS online framework for transferring data with sockets. This software attempts to wrap the low-level socket library to ease higher-level programming with an API based on an asynchronous event driven model similar to the DAT uDAPL API. It is an event-based application with NUMA optimizations, that allows for a high throughput of data across a large distributed system. This paper describes the architecture, the technologies involved and the performance measurements of the software in the context of the CMS distributed event building.« less
Failure Mode Classification for Life Prediction Modeling of Solid-State Lighting
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sakalaukus, Peter Joseph
2015-08-01
Since the passing of the Energy Independence and Security Act of 2007, the U.S. government has mandated greater energy independence which has acted as a catalyst for accelerating and facilitating research efforts toward the development and deployment of market-driven solutions for energy-saving homes, buildings and manufacturing, as well as sustainable transportation and renewable electricity generation. As part of this effort, an emphasis toward advancing solid-state lighting technology through research, development, demonstration, and commercial applications is assisting in the phase out of the common incandescent light bulb, as well as developing a more economical lighting source that is less toxic thanmore » compact fluorescent lighting. This has led lighting manufacturers to pursue SSL technologies for a wide range of consumer lighting applications. An SSL luminaire’s lifetime can be characterized in terms of lumen maintenance life. Lumen maintenance or lumen depreciation is the percentage decrease in the relative luminous flux from that of the original, pristine luminous flux value. Lumen maintenance life is the estimated operating time, in hours, when the desired failure threshold is projected to be reached at normal operating conditions. One accepted failure threshold of SSL luminaires is lumen maintenance of 70% -- a 30% reduction in the light output of the luminaire. Currently, the only approved lighting standard that puts forth a recommendation for long-term luminous flux maintenance projections towards a specified failure threshold of an SSL luminaire is the IES TM-28-14 (TM28) standard. iii TM28 was derived as a means to compare luminaires that have been tested at different facilities, research labs or companies. TM28 recommends the use of the Arrhenius equation to determine SSL device specific reaction rates from thermally driven failure mechanisms used to characterize a single failure mode – the relative change in the luminous flux output or “light power” of the SSL luminaire. The use of the Arrhenius equation necessitates two different temperature conditions, 25°C and 45°C are suggested by TM28, to determine the SSL lamp specific activation energy. One principal issue with TM28 is the lack of additional stresses or parameters needed to characterize non-temperature dependent failure mechanisms. Another principal issue with TM28 is the assumption that lumen maintenance or lumen depreciation gives an adequate comparison between SSL luminaires. Additionally, TM28 has no process for the determination of acceleration factors or lifetime estimations. Currently, a literature gap exists for established accelerated test methods for SSL devices to assess quality, reliability and durability before being introduced into the marketplace. Furthermore, there is a need for Physics-of-Failure based approaches to understand the processes and mechanisms that induce failure for the assessment of SSL reliability in order to develop generalized acceleration factors that better represent SSL product lifetime. This and the deficiencies in TM28 validate the need behind the development of acceleration techniques to quantify SSL reliability under a variety of environmental conditions. The ability to assess damage accrual and investigate reliability of SSL components and systems is essential to understanding the life time of the SSL device itself. The methodologies developed in this work increases the understanding of SSL devices iv through the investigation of component and device reliability under a variety of accelerated test conditions. The approaches for suitable lifetime predictions through the development of novel generalized acceleration factors, as well as a prognostics and health management framework, will greatly reduce the time and effort needed to produce SSL acceleration factors for the development of lifetime predictions.« less
Zadeh, Homayoun H; Abdelhamid, Alaa; Omran, Mostafa; Bakhshalian, Neema; Tarnow, Dennis
2016-06-01
The aims of this study were to evaluate (i) the efficacy of ridge preservation and repair involving SocketKAP(™) and SocketKAGE(™) devices following tooth removal; and (ii) ridge contour changes at 6 months post-extraction in intact sockets and sockets with dehiscence defects. Thirty-six patients required a total of 61 teeth to be extracted. Five cohorts were established with groups A-C involving intact sockets and groups D and E involving facial dehiscence: (A) Negative Control; (B) SocketKAP(™) alone; (C) Anorganic Bovine Bone Mineral (ABBM) + SocketKAP(™) ; (D) Negative Control; and (E) ABBM + SocketKAP(™) + SocketKAGE(™) . Preoperative CBCT and laser-scanned casts were obtained. Teeth segmented from preoperative CBCT were merged with study cast images to allow for digital removal of teeth from the casts. Volumetric measurements of ridge contour were performed. Images of preoperative and 6 months post-operative casts were superimposed to measure ridge contour changes. Post-extraction contour loss occurred in all sockets primarily in the crestal 3 mm but was also detected up to 6 mm from alveolar crest. For intact sockets, SocketKAP(™) or SocketKAP(™) + ABBM interventions led to greater percentages of remaining ridge contour when compared to controls. A significant difference favoring SocketKAP(™) + SocketKAGE(™) + ABBM treatment was observed for sockets with facial dehiscence when compared to controls. SocketKAP(™) , with or without ABBM, significantly limited post-extraction ridge contour loss in intact sockets. In the absence of a group treated with only the SocketKAGE(™) , it is not possible to determine its efficacy, although the combination of SocketKAGE(™) + SocketKAP(™) + ABBM was effective in limiting post-extraction ridge contour loss in sockets with dehiscence defects. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Wang, Dan; Fu, Jijun; Shi, Yujie; Peng, Dong; Yuan, Lan; He, Bing; Dai, Wenbing; Zhang, Hua; Wang, Xueqing; Tian, Jie; Zhang, Qiang
2016-09-28
The transport of nanocarriers is supposed to be based on EPR effect which is affected by diverse factors, so the modulation of EPR effect seems very significant for nanocarriers including targeted drug delivery systems (TDDSs). Besides, it is extremely unclear how the EPR effect impacts the fate of different types of TDDSs. To make the most advantage of EPR effect for TDDSs, it is definitely necessary to clarify these key issues. Here, we construct and characterize various TDDSs, including sterically-stabilized liposomes (SSL), RGD functionalized SSL (RGD-SSL) and novel 7PEP functionalized SSL (7PEP-SSL), loaded with doxorubicin (DOX), DIR or DID. Here, we modulate the permeability of tumor vessels by thalidomide (THD) in a sarcoma-bearing EPR mouse model via monitoring endogenous deoxygenated hemoglobin in circulation, and then we confirm the effect of THD on tumor vessel permeability by vessel density, vessel maturity, VEGF expression and so on. Importantly, we investigate and find the impacts of EPR effect on the antitumor efficacy, in vivo distribution and intratumoral microdistribution of the three TDDSs. Interestingly, the EPR effects affect different TDDSs differently. The elevated EPR effect enhances the tumor accumulation of SSL and RGD-SSL but fails to increase their efficacy. The RGD-SSL exhibits the best efficacy with the least fluctuation, demonstrating the advantage of angiogenesis targeted systems. 7PEP-SSL seems the biggest beneficiary of EPR effect, suggesting the significance of EPR modulation for cells targeted systems. Generally, this study demonstrates the feasibility of modulating EPR effect bidirectionally by THD as well as the impacts of EPR effect on different type of testing TDDSs based on this animal model. It certainly provides novel insight into the design and potential use of TDDSs. Copyright © 2016 Elsevier B.V. All rights reserved.
2009-09-01
boarding team, COTS, WLAN, smart antenna, OpenVPN application, wireless base station, OFDM, latency, point-to-point wireless link. 16. PRICE CODE 17...16 c. SSL/TLS .................................17 2. OpenVPN ......................................17 III. EXPERIMENT METHODOLOGY...network frame at Layer 2 has already been secured by encryption at a higher level. 2. OpenVPN OpenVPN is open source software that provides a VPN
An Analysis of the Computer Security Ramifications of Weakened Asymmetric Cryptographic Algorithms
2012-06-01
OpenVPN (Yonan). TLS (and by extension SSL) obviously rely on encryption to provide the confidentiality, integrity and authentication services it...Secure Shell (SSH) Transport Layer Protocol.” IETF, Jan. 2006. <tools.ietf.org/html/rfc4253> Yonan, James, and Mattock. " OpenVPN ." SourceForge...11 May 2012. <http://sourceforge.net/projects/ openvpn /> 92 REPORT DOCUMENTATION PAGE Form Approved OMB No. 074-0188 The public reporting
Unified Behavior Framework for Discrete Event Simulation Systems
2015-03-26
I would like to thank Dr. Hodson for his guidance and direction throughout the AFIT program. I also would like to thank my thesis committee members...SPA Sense-Plan-Act SSL System Service Layer TCA Task Control Architecture TRP Teleo-Reactive Program UAV Unmanned Aerial Vehicle UBF Unified Behavior...a teleo-reactive architecture [11]. Teleo-Reactive Programs ( TRPs ) are composed of a list of rules, where each has a condition and an action. When the
Light-emitting diode technology status and directions: Opportunities for horticultural lighting
Tsao, Jeffrey Y.; Pattison, P. Morgan; Krames, Michael R.
2016-01-01
Here, light-emitting diode (LED) technology has advanced rapidly over the last decade, primarily driven by display and general illumination applications ("solid-state lighting (SSL) for humans"). These advancements have made LED lighting technically and economically advantageous not only for these applications, but also, as an indirect benefit, for adjacent applications such as horticultural lighting ("SSL for plants"). Moreover, LED technology has much room for continued improvement. In the near-term, these improvements will continue to be driven by SSL for humans (with indirect benefit to SSL for plants), the most important of which can be anticipated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Copeland, Robert Guild; Mitchell, Christine Charlotte; Follstaedt, David Martin
This SAND report is the final report on Sandia's Grand Challenge LDRD Project 27328, 'A Revolution in Lighting -- Building the Science and Technology Base for Ultra-Efficient Solid-state Lighting.' This project, which for brevity we refer to as the SSL GCLDRD, is considered one of Sandia's most successful GCLDRDs. As a result, this report reviews not only technical highlights, but also the genesis of the idea for Solid-state Lighting (SSL), the initiation of the SSL GCLDRD, and the goals, scope, success metrics, and evolution of the SSL GCLDRD over the course of its life. One way in which the SSLmore » GCLDRD was different from other GCLDRDs was that it coincided with a larger effort by the SSL community - primarily industrial companies investing in SSL, but also universities, trade organizations, and other Department of Energy (DOE) national laboratories - to support a national initiative in SSL R&D. Sandia was a major player in publicizing the tremendous energy savings potential of SSL, and in helping to develop, unify and support community consensus for such an initiative. Hence, our activities in this area, discussed in Chapter 6, were substantial: white papers; SSL technology workshops and roadmaps; support for the Optoelectronics Industry Development Association (OIDA), DOE and Senator Bingaman's office; extensive public relations and media activities; and a worldwide SSL community website. Many science and technology advances and breakthroughs were also enabled under this GCLDRD, resulting in: 55 publications; 124 presentations; 10 book chapters and reports; 5 U.S. patent applications including 1 already issued; and 14 patent disclosures not yet applied for. Twenty-six invited talks were given, at prestigious venues such as the American Physical Society Meeting, the Materials Research Society Meeting, the AVS International Symposium, and the Electrochemical Society Meeting. This report contains a summary of these science and technology advances and breakthroughs, with Chapters 1-5 devoted to the five technical task areas: 1 Fundamental Materials Physics; 2 111-Nitride Growth Chemistry and Substrate Physics; 3 111-Nitride MOCVD Reactor Design and In-Situ Monitoring; 4 Advanced Light-Emitting Devices; and 5 Phosphors and Encapsulants. Chapter 7 (Appendix A) contains a listing of publications, presentations, and patents. Finally, the SSL GCLDRD resulted in numerous actual and pending follow-on programs for Sandia, including multiple grants from DOE and the Defense Advanced Research Projects Agency (DARPA), and Cooperative Research and Development Agreements (CRADAs) with SSL companies. Many of these follow-on programs arose out of contacts developed through our External Advisory Committee (EAC). In h s and other ways, the EAC played a very important role. Chapter 8 (Appendix B) contains the full (unedited) text of the EAC reviews that were held periodically during the course of the project.« less
Effects of Socket Size on Metrics of Socket Fit in Trans-Tibial Prosthesis Users
Sanders, Joan E; Youngblood, Robert T; Hafner, Brian J; Cagle, John C; McLean, Jake B; Redd, Christian B; Dietrich, Colin R; Ciol, Marcia A; Allyn, Katheryn J
2017-01-01
The purpose of this research was to conduct a preliminary effort to identify quantitative metrics to distinguish a good socket from an oversized socket in people with trans-tibial amputation. Results could be used to inform clinical practices related to socket replacement. A cross-over study was conducted on community ambulators (K-level 3 or 4) with good residual limb sensation. Participants were each provided with two sockets, a duplicate of their as-prescribed socket and a modified socket that was enlarged or reduced by 1.8 mm (~6% of the socket volume) based on the fit quality of the as-prescribed socket. The two sockets were termed a larger socket and a smaller socket. Activity was monitored while participants wore each socket for 4wk. Participants’ gait; self-reported satisfaction, quality of fit, and performance; socket comfort; and morning-to-afternoon limb fluid volume changes were assessed. Visual analysis of plots and estimated effect sizes (measure as mean difference divided by standard deviation) showed largest effects for step time asymmetry, step width asymmetry, anterior and anterior-distal morning-to-afternoon fluid volume change, socket comfort scores, and self-reported measures of utility, satisfaction, and residual limb health. These variables may be viable metrics for early detection of deterioration in socket fit, and should be tested in a larger clinical study. PMID:28373013
Effects of socket size on metrics of socket fit in trans-tibial prosthesis users.
Sanders, Joan E; Youngblood, Robert T; Hafner, Brian J; Cagle, John C; McLean, Jake B; Redd, Christian B; Dietrich, Colin R; Ciol, Marcia A; Allyn, Katheryn J
2017-06-01
The purpose of this research was to conduct a preliminary effort to identify quantitative metrics to distinguish a good socket from an oversized socket in people with trans-tibial amputation. Results could be used to inform clinical practices related to socket replacement. A cross-over study was conducted on community ambulators (K-level 3 or 4) with good residual limb sensation. Participants were each provided with two sockets, a duplicate of their as-prescribed socket and a modified socket that was enlarged or reduced by 1.8mm (∼6% of the socket volume) based on the fit quality of the as-prescribed socket. The two sockets were termed a larger socket and a smaller socket. Activity was monitored while participants wore each socket for 4 weeks. Participants' gait; self-reported satisfaction, quality of fit, and performance; socket comfort; and morning-to-afternoon limb fluid volume changes were assessed. Visual analysis of plots and estimated effect sizes (measured as mean difference divided by standard deviation) showed largest effects for step time asymmetry, step width asymmetry, anterior and anterior-distal morning-to-afternoon fluid volume change, socket comfort score, and self-reported utility. These variables may be viable metrics for early detection of deterioration in socket fit, and should be tested in a larger clinical study. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
Kant, Nora; Müller, Ruth; Braun, Markus; Gerber, Alexander; Groneberg, David
2016-08-08
Indoor air pollution with harmful particulate matter (PM) is mainly caused by cigarette smoke. Super-Slim-Size-Cigarettes (SSL) are considered a less harmful alternative to King-Size-Cigarettes (KSC) due to longer filters and relatively low contents. We ask if "Combined Mainstream and Sidestream Smoke" (CMSS)-associated PM levels of SSL are lower than of KSC and thus are potentially less harmful. PM concentrations in CMSS (PM10, PM2.5, and PM₁) are measured from four cigarette types of the brand Vogue, using an "automatic-environmental-tobacco-smoke-emitter" (AETSE) and laser aerosol spectrometry: SSL-BLEUE, -MENTHE, -LILAS and KSC-La Cigarette and -3R4F reference. This analysis shows that SSL MENTHE emitted the highest amount of PM, and KSC-La Cigarette the lowest. 3R4F reference emitted PM in the middle range, exceeding SSL BLEUE and falling slightly below SSL LILAS. It emerged that PM₁ constituted the biggest proportion of PM emission. The outcome shows significant type-specific differences for emitted PM concentrations. Our results indicate that SSL are potentially more harmful for passive smokers than the respective KSC. However, this study cannot give precise statements about the general influence of the size of a cigarette on PM. Alarming is that PM₁ is responsible for the biggest proportion of PM pollution, since smaller particles cause more harmful effects.
Fatone, Stefania; Caldwell, Ryan
2017-06-01
Current transfemoral prosthetic sockets are problematic as they restrict function, lack comfort, and cause residual limb problems. Development of a subischial socket with lower proximal trim lines is an appealing way to address this problem and may contribute to improving quality of life of persons with transfemoral amputation. The purpose of this study was to illustrate the use of a new subischial socket in two subjects. Case series. Two unilateral transfemoral prosthesis users participated in preliminary socket evaluations comparing functional performance of the new subischial socket to ischial containment sockets. Testing included gait analysis, socket comfort score, and performance-based clinical outcome measures (Rapid-Sit-To-Stand, Four-Square-Step-Test, and Agility T-Test). For both subjects, comfort was better in the subischial socket, while gait and clinical outcomes were generally comparable between sockets. While these evaluations are promising regarding the ability to function in this new socket design, more definitive evaluation is needed. Clinical relevance Using gait analysis, socket comfort score and performance-based outcome measures, use of the Northwestern University Flexible Subischial Vaccum Socket was evaluated in two transfemoral prosthesis users. Socket comfort improved for both subjects with comparable function compared to ischial containment sockets.
Computer-socket manufacturing error: How much before it is clinically apparent?
Sanders, Joan E.; Severance, Michael R.; Allyn, Kathryn J.
2015-01-01
The purpose of this research was to pursue quality standards for computer-manufacturing of prosthetic sockets for people with transtibial limb loss. Thirty-three duplicates of study participants’ normally used sockets were fabricated using central fabrication facilities. Socket-manufacturing errors were compared with clinical assessments of socket fit. Of the 33 sockets tested, 23 were deemed clinically to need modification. All 13 sockets with mean radial error (MRE) greater than 0.25 mm were clinically unacceptable, and 11 of those were deemed in need of sizing reduction. Of the remaining 20 sockets, 5 sockets with interquartile range (IQR) greater than 0.40 mm were deemed globally or regionally oversized and in need of modification. Of the remaining 15 sockets, 5 sockets with closed contours of elevated surface normal angle error (SNAE) were deemed clinically to need shape modification at those closed contour locations. The remaining 10 sockets were deemed clinically acceptable and not in need modification. MRE, IQR, and SNAE may serve as effective metrics to characterize quality of computer-manufactured prosthetic sockets, helping facilitate the development of quality standards for the socket manufacturing industry. PMID:22773260
Design of a novel prosthetic socket: assessment of the thermal performance.
Webber, Christina M; Davis, Brian L
2015-05-01
Prosthetic liners and sockets insulate the residual limb, causing excessive sweating and concomitant skin maceration. When coupled with atypical loading conditions, further dermatologic problems can arise. This can significantly reduce the quality of life of an amputee patient. Improving the design of the prosthetic socket has been proposed as a means of reestablishing a normal thermal environment around the residual limb. In this study, a prosthetic socket was modified by incorporating a helical cooling channel within the socket wall using additive manufacturing techniques. Two sockets were modeled: a control socket, and a modified socket containing a 0.48 cm diameter cooling channel. Computer simulations and bench-top testing were used to assess the design's ability to create a greater temperature differential across the socket wall. A greater temperature drop across the socket wall suggested that the socket could provide cooling benefits to the residual limb by allowing for heat to be drawn away from the limb. The temperature difference across the socket wall was calculated for both sockets in each aspect of the study. Both socket type (p=0.002) and location on the socket (p=0.014) were statistically significant factors affecting the temperature difference between inner and outer socket walls. Compared with the control socket, the modified socket containing a helical cooling channel exhibited greater temperature differences across its wall of 11.1 °C and 6.4 °C in the computer simulations and bench-top testing, respectively. This finding suggested that socket modifications, such as the cooling channel presented, could provide a beneficial cooling effect to an amputee patient's residual limb. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Rodrigues, Rita C. L. B.; Lu, Chenfeng; Lin, Bernice; Jeffries, Thomas W.
Spent sulfite pulping liquor (SSL) contains lignin, which is present as lignosulfonate, and hemicelluloses that are present as hydrolyzed carbohydrates. To reduce the biological oxygen demand of SSL associated with dissolved sugars, we studied the capacity of Pichia stipitis FPL-YS30 (xyl3Δ) to convert these sugars into useful products. FPL-YS30 produces a negligible amount of ethanol while converting xylose into xylitol. This work describes the xylose fermentation kinetics of yeast strain P.stipitis FPL-YS30. Yeast was grown in rich medium supplemented with different carbon sources: glucose, xylose, or ammonia-base SSL. The SSL and glucose-acclimatized cells showed similar maximum specific growth rates (0.146 h-1). The highest xylose consumption at the beginning of the fermentation process occurred using cells precultivated in xylose, which showed relatively high specific activity of glucose-6-phosphate dehydrogenase (EC 1.1.1.49). However, the maximum specific rates of xylose consumption (0.19 gxylose/gcel h) and xylitol production (0.059 gxylitol/gcel h) were obtained with cells acclimatized in glucose, in which the ratio between xylose reductase (EC 1.1.1.21) and xylitol dehydrogenase (EC 1.1.1.9) was kept at higher level (0.82). In this case, xylitol production (31.6 g/l) was 19 and 8% higher than in SSL and xylose-acclimatized cells, respectively. Maximum glycerol (6.26 g/l) and arabitol (0.206 g/l) production were obtained using SSL and xylose-acclimatized cells, respectively. The medium composition used for the yeast precultivation directly reflected their xylose fermentation performance. The SSL could be used as a carbon source for cell production. However, the inoculum condition to obtain a high cell concentration in SSL needs to be optimized.
Polynuclear aromatic hydrocarbon analysis using the synchronous scanning luminoscope
NASA Astrophysics Data System (ADS)
Hyfantis, George J., Jr.; Teglas, Matthew S.; Wilbourn, Robert G.
2001-02-01
12 The Synchronous Scanning Luminoscope (SSL) is a field- portable, synchronous luminescence spectrofluorometer that was developed for on-site analysis of contaminated soil and ground water. The SSL is capable of quantitative analysis of total polynuclear aromatic hydrocarbons (PAHs) using phosphorescence and fluorescence techniques with a high correlation to laboratory data as illustrated by this study. The SSL is also capable of generating benzo(a)pyrene equivalency results, based on seven carcinogenic PAHs and Navy risk numbers, with a high correlation to laboratory data as illustrated by this study. These techniques allow rapid field assessments of total PAHs and benzo(a)pyrene equivalent concentrations. The Luminoscope is capable of detecting total PAHs to the parts per billion range. This paper describes standard field methods for using the SSL and describes the results of field/laboratory testing of PAHs. SSL results from two different hazardous waste sites are discussed.
Gerschutz, Maria J; Haynes, Michael L; Nixon, Derek M; Colvin, James M
2011-01-01
Prosthetic sockets serve as the interface between people with amputations and their prostheses. Although most materials used to make prosthetic sockets have been used for many years, knowledge of these materials' properties is limited, especially after they are subjected to fabrication processes. This study evaluated tensile and impact properties of the current state-of-the-art materials used to fabricate prosthetic check sockets, copolymer sockets, and definitive laminated sockets. Thermolyn Rigid and Orfitrans Stiff check socket materials produced significantly lower tensile strength and impact resistance than polyethylene terephthalate glycol (PETG). Copolymer socket materials exhibited greater resistance to impact forces than the check socket materials but lower tensile strengths than PETG. The heated molding processes, for the check socket and copolymer materials, reduced both tensile strength and elongation at break. Definitive laminated sockets were sorted according to fabrication techniques. Nyglass material had significantly higher elongation, indicating a more ductile material than carbon-based laminations. Carbon sockets with pigmented resin had higher tensile strength and modulus at break than nonpigmented carbon sockets. Elongation at yield and elongation at break were similar for both types of carbon-based laminations. The material properties determined in this study provide a foundation for understanding and improving the quality of prosthetic sockets using current fabrication materials and a basis for evaluating future technologies.
Fatone, Stefania; Caldwell, Ryan
2017-01-01
Background: Current transfemoral prosthetic sockets are problematic as they restrict function, lack comfort, and cause residual limb problems. Development of a subischial socket with lower proximal trim lines is an appealing way to address this problem and may contribute to improving quality of life of persons with transfemoral amputation. Objectives: The purpose of this study was to illustrate the use of a new subischial socket in two subjects. Study design: Case series. Methods: Two unilateral transfemoral prosthesis users participated in preliminary socket evaluations comparing functional performance of the new subischial socket to ischial containment sockets. Testing included gait analysis, socket comfort score, and performance-based clinical outcome measures (Rapid-Sit-To-Stand, Four-Square-Step-Test, and Agility T-Test). Results: For both subjects, comfort was better in the subischial socket, while gait and clinical outcomes were generally comparable between sockets. Conclusion: While these evaluations are promising regarding the ability to function in this new socket design, more definitive evaluation is needed. Clinical relevance Using gait analysis, socket comfort score and performance-based outcome measures, use of the Northwestern University Flexible Subischial Vaccum Socket was evaluated in two transfemoral prosthesis users. Socket comfort improved for both subjects with comparable function compared to ischial containment sockets. PMID:28132589
Solid-State Lighting: Early Lessons Learned on the Way to Market
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandahl, Linda J.; Cort, Katherine A.; Gordon, Kelly L.
2013-12-31
The purpose of this report is to document early challenges and lessons learned in the solid-state lighting (SSL) market development as part of the DOE’s SSL Program efforts to continually evaluate market progress in this area. This report summarizes early actions taken by DOE and others to avoid potential problems anticipated based on lessons learned from the market introduction of compact fluorescent lamps and identifies issues, challenges, and new lessons that have been learned in the early stages of the SSL market introduction. This study identifies and characterizes12 key lessons that have been distilled from DOE SSL program results.
Dry Socket Etiology, Diagnosis, and Clinical Treatment Techniques.
Mamoun, John
2018-04-01
Dry socket, also termed fibrinolytic osteitis or alveolar osteitis, is a complication of tooth exodontia. A dry socket lesion is a post-extraction socket that exhibits exposed bone that is not covered by a blood clot or healing epithelium and exists inside or around the perimeter of the socket or alveolus for days after the extraction procedure. This article describes dry socket lesions; reviews the basic clinical techniques of treating different manifestations of dry socket lesions; and shows how microscope level loupe magnification of 6× to 8× or greater, combined with co-axial illumination or a dental operating microscope, facilitate more precise treatment of dry socket lesions. The author examines the scientific validity of the proposed causes of dry socket lesions (such as bacteria, inflammation, fibrinolysis, or traumatic extractions) and the scientific validity of different terminologies used to describe dry socket lesions. This article also presents an alternative model of what causes dry socket lesions, based on evidence from dental literature. Although the clinical techniques for treating dry socket lesions seem empirically correct, more evidence is required to determine the causes of dry socket lesions.
Dry Socket Etiology, Diagnosis, and Clinical Treatment Techniques
2018-01-01
Dry socket, also termed fibrinolytic osteitis or alveolar osteitis, is a complication of tooth exodontia. A dry socket lesion is a post-extraction socket that exhibits exposed bone that is not covered by a blood clot or healing epithelium and exists inside or around the perimeter of the socket or alveolus for days after the extraction procedure. This article describes dry socket lesions; reviews the basic clinical techniques of treating different manifestations of dry socket lesions; and shows how microscope level loupe magnification of 6× to 8× or greater, combined with co-axial illumination or a dental operating microscope, facilitate more precise treatment of dry socket lesions. The author examines the scientific validity of the proposed causes of dry socket lesions (such as bacteria, inflammation, fibrinolysis, or traumatic extractions) and the scientific validity of different terminologies used to describe dry socket lesions. This article also presents an alternative model of what causes dry socket lesions, based on evidence from dental literature. Although the clinical techniques for treating dry socket lesions seem empirically correct, more evidence is required to determine the causes of dry socket lesions. PMID:29732309
Kant, Nora; Müller, Ruth; Braun, Markus; Gerber, Alexander; Groneberg, David
2016-01-01
Indoor air pollution with harmful particulate matter (PM) is mainly caused by cigarette smoke. Super-Slim-Size-Cigarettes (SSL) are considered a less harmful alternative to King-Size-Cigarettes (KSC) due to longer filters and relatively low contents. We ask if “Combined Mainstream and Sidestream Smoke” (CMSS)-associated PM levels of SSL are lower than of KSC and thus are potentially less harmful. PM concentrations in CMSS (PM10, PM2.5, and PM1) are measured from four cigarette types of the brand Vogue, using an “automatic-environmental-tobacco-smoke-emitter” (AETSE) and laser aerosol spectrometry: SSL-BLEUE, -MENTHE, -LILAS and KSC-La Cigarette and -3R4F reference. This analysis shows that SSL MENTHE emitted the highest amount of PM, and KSC-La Cigarette the lowest. 3R4F reference emitted PM in the middle range, exceeding SSL BLEUE and falling slightly below SSL LILAS. It emerged that PM1 constituted the biggest proportion of PM emission. The outcome shows significant type-specific differences for emitted PM concentrations. Our results indicate that SSL are potentially more harmful for passive smokers than the respective KSC. However, this study cannot give precise statements about the general influence of the size of a cigarette on PM. Alarming is that PM1 is responsible for the biggest proportion of PM pollution, since smaller particles cause more harmful effects. PMID:27509517
Harner, Nicole K; Bajwa, Paramjit K; Habash, Marc B; Trevors, Jack T; Austin, Glen D; Lee, Hung
2014-01-01
A strain development program was initiated to improve the tolerance of the pentose-fermenting yeast Pachysolen tannophilus to inhibitors in lignocellulosic hydrolysates. Several rounds of UV mutagenesis followed by screening were used to select for mutants of P. tannophilus NRRL Y2460 with improved tolerance to hardwood spent sulfite liquor (HW SSL) and acetic acid in separate selection lines. The wild type (WT) strain grew in 50 % (v/v) HW SSL while third round HW SSL mutants (designated UHW301, UHW302 and UHW303) grew in 60 % (v/v) HW SSL, with two of these isolates (UHW302 and UHW303) being viable and growing, respectively, in 70 % (v/v) HW SSL. In defined liquid media containing acetic acid, the WT strain grew in 0.70 % (w/v) acetic acid, while third round acetic acid mutants (designated UAA301, UAA302 and UAA303) grew in 0.80 % (w/v) acetic acid, with one isolate (UAA302) growing in 0.90 % (w/v) acetic acid. Cross-tolerance of HW SSL-tolerant mutants to acetic acid and vice versa was observed with UHW303 able to grow in 0.90 % (w/v) acetic acid and UAA302 growing in 60 % (v/v) HW SSL. The UV-induced mutants retained the ability to ferment glucose and xylose to ethanol in defined media. These mutants of P. tannophilus are of considerable interest for bioconversion of the sugars in lignocellulosic hydrolysates to ethanol.
Secure electronic commerce communication system based on CA
NASA Astrophysics Data System (ADS)
Chen, Deyun; Zhang, Junfeng; Pei, Shujun
2001-07-01
In this paper, we introduce the situation of electronic commercial security, then we analyze the working process and security for SSL protocol. At last, we propose a secure electronic commerce communication system based on CA. The system provide secure services such as encryption, integer, peer authentication and non-repudiation for application layer communication software of browser clients' and web server. The system can implement automatic allocation and united management of key through setting up the CA in the network.
NASA Astrophysics Data System (ADS)
Fathirad, Iraj; Devlin, John; Jiang, Frank
2012-09-01
The key-exchange and authentication are two crucial elements of any network security mechanism. IPsec, SSL/TLS, PGP and S/MIME are well-known security approaches in providing security service to network, transport and application layers; these protocols use different methods (based on their requirements) to establish keying materials and authenticates key-negotiation and participated parties. This paper studies and compares the authenticated key negotiation methods in mentioned protocols.
Securing SSL-VPN with LR-AKE to access personal health record.
Eizen, Kimura; Masato, Saito; Kazukuni, Kobara; Yoshihito, Nakato; Takuji, Kuroda; Ken, Ishihara
2013-01-01
Using SSL-VPN requires special considerations for well-known issues such as attackers exploiting web browser vulnerabilities and phishing sites using man-in-the-middle attacks. We used leakage-resilient authenticated key exchange (LR-AKE) to develop a comprehensive solution to SSL-VPN issues. Our results show that the LR-AKE should contribute to building a robust infrastructure for personal health records.
Using the ACR/NEMA standard with TCP/IP and Ethernet
NASA Astrophysics Data System (ADS)
Chimiak, William J.; Williams, Rodney C.
1991-07-01
There is a need for a consolidated picture archival and communications system (PACS) in hospitals. At the Bowman Gray School of Medicine of Wake Forest University (BGSM), the authors are enhancing the ACR/NEMA Version 2 protocol using UNIX sockets and TCP/IP to greatly improve connectivity. Initially, nuclear medicine studies using gamma cameras are to be sent to PACS. The ACR/NEMA Version 2 protocol provides the functionality of the upper three layers of the open system interconnection (OSI) model in this implementation. The images, imaging equipment information, and patient information are then sent in ACR/NEMA format to a software socket. From there it is handed to the TCP/IP protocol, which provides the transport and network service. TCP/IP, in turn, uses the services of IEEE 802.3 (Ethernet) to complete the connectivity. The advantage of this implementation is threefold: (1) Only one I/O port is consumed by numerous nuclear medicine cameras, instead of a physical port for each camera. (2) Standard protocols are used which maximize interoperability with ACR/NEMA compliant PACSs. (3) The use of sockets allows a migration path to the transport and networking services of OSIs TP4 and connectionless network service as well as the high-performance protocol being considered by the American National Standards Institute (ANSI) and the International Standards Organization (ISO) -- the Xpress Transfer Protocol (XTP). The use of sockets also gives access to ANSI's Fiber Distributed Data Interface (FDDI) as well as other high-speed network standards.
Sloto, Ronald A.; Olson, Leif E.
2011-01-01
Turbidity and suspended-sediment concentration data were collected by the U.S. Geological Survey (USGS) at four stream stations--French Creek near Phoenixville, West Branch Brandywine Creek near Honey Brook, West Branch Brandywine Creek at Modena, and East Branch Brandywine Creek below Downingtown--in Chester County, Pa. Sedimentation and siltation is the leading cause of stream impairment in Chester County, and these data are critical for quantifying sediment transport. This study was conducted by the USGS in cooperation with the Chester County Water Resources Authority and the Chester County Health Department. Data from optical turbidity sensors deployed at the four stations were recorded at 15- or 30-minute intervals by a data logger and uploaded every 1 to 4 hours to the USGS database. Most of the suspended-sediment samples were collected using automated samplers. The use of optical sensors to continuously monitor turbidity provided an accurate estimate of sediment fluctuations without the collection and analysis costs associated with intensive sampling during storms. Turbidity was used as a surrogate for suspended-sediment concentration (SSC), which is a measure of sedimentation and siltation. Regression models were developed between SSC and turbidity for each of the monitoring stations using SSC data collected from the automated samplers and turbidity data collected at each station. Instantaneous suspended-sediment loads (SSL) were computed from time-series turbidity and discharge data for the 2008 and 2009 water years using the regression equations. The instantaneous computations of SSL were summed to provide daily, storm, and water year annual loads. The annual SSL contributed from each basin was divided by the upstream drainage area to estimate the annual sediment yield. For all four basins, storms provided more than 96 percent of the annual SSL. In each basin, four storms generally provided over half the annual SSL each water year. Stormflows with the highest peak discharges generally carried the highest SSLs. For all stations, the greatest SSLs occurred during the late winter in February and March during the 2008 water year. During the 2009 water year, the greatest SSLs occurred during December and August. For French Creek near Phoenixville, the estimated annual SSL was 3,500 tons, and the estimated yield was 59.1 tons per square mile (ton/mi2) for the 2008 water year. For the 2009 water year, the annual SSL was 4,390 tons, and the yield was 74.3 ton/mi2. For West Branch Brandywine Creek near Honey Brook, the estimated annual SSL was 4,580 tons, and the estimated yield was 245 ton/mi2 for the 2008 water year. For the 2009 water year, the annual SSL was 2,300 tons, and the yield was 123 ton/mi2. For West Branch Brandywine Creek at Modena, the estimated annual SSL was 7,480 tons, and the estimated yield was 136 ton/mi2 for the 2008 water year. For the 2009 water year, the annual SSL was 4,930 tons, and the yield was 90 ton/mi2. For East Branch Brandywine Creek below Downingtown, the estimated annual SSL was 8,900 tons, and the estimated yield was 100 ton/mi2 for the 2008 water year. For the 2009 water year, the annual SSL was 7,590 tons, and the yield was 84 ton/mi2.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wierer, Jonathan J.; Tsao, Jeffrey Y.; Sizov, Dmitry S.
Solid-state lighting (SSL) is now the most efficient source of high color quality white light ever created. Nevertheless, the blue InGaN light-emitting diodes (LEDs) that are the light engine of SSL still have significant performance limitations. Foremost among these is the decrease in efficiency at high input current densities widely known as “efficiency droop.” Efficiency droop limits input power densities, contrary to the desire to produce more photons per unit LED chip area and to make SSL more affordable. Pending a solution to efficiency droop, an alternative device could be a blue laser diode (LD). LDs, operated in stimulated emission,more » can have high efficiencies at much higher input power densities than LEDs can. In this article, LEDs and LDs for future SSL are explored by comparing: their current state-of-the-art input-power-density-dependent power-conversion efficiencies; potential improvements both in their peak power-conversion efficiencies and in the input power densities at which those efficiencies peak; and their economics for practical SSL.« less
Niu, Meng; Hou, Gary G; Kindelspire, Julie; Krishnan, Padmanaban; Zhao, Siming
2017-05-15
With the utilization of enzymes including endoxylanase, glucose oxidase (GOX) and transglutaminase (TG), and emulsifiers comprising sodium stearoyl lactate (SSL) and soy lecithin, the microstructural, textural, and sensory properties of whole-wheat noodle (WWN) were modified. The development time and stability of whole-wheat dough (WWD) were enhanced by TG due to the formation of a more compact gluten network, and by SSL resulting from the enhanced gluten strength. Microstructure graphs by scanning electron microscopy (SEM) verified that TG and SSL promoted the connectivity of gluten network and the coverage of starch granules in WWN. TG increased the hardness and elasticity of cooked WWN, while two emulsifiers increased the noodle cohesiveness. Additionally, TG and SSL improved the sensory properties of noodle such as bite, springiness, and mouth-feel. The results suggest that TG and SSL are effective ingredients in enhancing the gluten strength of WWD and improving the qualities of WWN. Copyright © 2016 Elsevier Ltd. All rights reserved.
Ortiz-Tafoya, M C; Rolland-Sabaté, Agnès; Garnier, Catherine; Valadez-García, Josefina; Tecante, Alberto
2018-08-01
Polysaccharide-surfactant blends are widely used in foods. However, their possible mutual interactions have not been extensively studied. The purpose of this work was to examine how the anionic surfactant sodium stearoyl lactylate (SSL) affects different properties of κ-carrageenan solutions and gels. Rheometry, differential scanning calorimetry, asymmetrical flow field-flow fractionation coupled with multiangle laser light scattering, among others, were used to determine the flow and viscoelastic behavior, thermal transitions, and conformation changes, respectively. Interference caused by SSL is postulated as the primary factor to explain the variations in the conformation of κ-carrageenan in gels and solutions. However, electrostatic repulsions between κ-carrageenan and SSL can also be involved. These latter interactions are more important for high SSL concentrations (13 mmol dm -3 ) without addition of KCl, because of the higher net negative charge density of the system. SSL significantly modifies the properties of κ-carrageenan in aqueous media. Copyright © 2018 Elsevier Ltd. All rights reserved.
Electrical grounding prong socket
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leong, R.
1989-09-12
This paper describes a socket for a grounding prong used in a three prong electrical plug. The socket being sufficiently spacious to prevent the socket from significantly stretching when a larger, U-shaped grounding prong is inserted into the socket, and having a ridge to allow a snug fit when a smaller tubular shape grounding prong is inserted into the socket. 11 figs.
Ibrahiem, Mohamed F. K.; Abdelaziz, Sahar T. A.
2016-01-01
Purpose. To evaluate a new surgical technique using fascia lata to deepen the shallow inferior conjunctival fornix in contracted socket and anophthalmic socket syndrome. Methods. A prospective controlled study in which 24 sockets of 24 patients who were unable to wear and retain their ocular prosthesis due to shallow inferior fornix were enrolled and categorized into anophthalmic socket syndromes (9 patients) and contracted sockets (15 patients). Another 24 patients who underwent evisceration or enucleation with healthy sockets and can wear and retain their prosthesis comfortably were chosen as a control group. Deepening of the fornix was performed using fascia lata strips under general anesthesia. Central depth of the inferior fornix was measured preoperatively and postoperatively. Results. A statistically significant improvement of the postoperative central inferior fornix depth was reported which was marked in anophthalmic subgroup. 100% of anophthalmic sockets and 93.3% of contracted sockets achieved satisfactory results during the follow-up period with no postoperative lower eyelid malposition or obvious skin scar. Conclusion. Fascia lata technique is a new alternative and effective procedure to deepen the shallow inferior fornix that can be used in moderate to severe contracted sockets or anophthalmic socket syndrome with minimal lower eyelid or socket complications. PMID:27313868
Ibrahiem, Mohamed F K; Abdelaziz, Sahar T A
2016-01-01
Purpose. To evaluate a new surgical technique using fascia lata to deepen the shallow inferior conjunctival fornix in contracted socket and anophthalmic socket syndrome. Methods. A prospective controlled study in which 24 sockets of 24 patients who were unable to wear and retain their ocular prosthesis due to shallow inferior fornix were enrolled and categorized into anophthalmic socket syndromes (9 patients) and contracted sockets (15 patients). Another 24 patients who underwent evisceration or enucleation with healthy sockets and can wear and retain their prosthesis comfortably were chosen as a control group. Deepening of the fornix was performed using fascia lata strips under general anesthesia. Central depth of the inferior fornix was measured preoperatively and postoperatively. Results. A statistically significant improvement of the postoperative central inferior fornix depth was reported which was marked in anophthalmic subgroup. 100% of anophthalmic sockets and 93.3% of contracted sockets achieved satisfactory results during the follow-up period with no postoperative lower eyelid malposition or obvious skin scar. Conclusion. Fascia lata technique is a new alternative and effective procedure to deepen the shallow inferior fornix that can be used in moderate to severe contracted sockets or anophthalmic socket syndrome with minimal lower eyelid or socket complications.
Fatone, Stefania; Caldwell, Ryan
2017-06-01
Current transfemoral prosthetic sockets restrict function, lack comfort, and cause residual limb problems. Lower proximal trim lines are an appealing way to address this problem. Development of a more comfortable and possibly functional subischial socket may contribute to improving quality of life of persons with transfemoral amputation. The purpose of this study was to (1) describe the design and fabrication of a new subischial socket and (2) describe efforts to teach this technique. Development project. Socket development involved defining the following: subject and liner selection, residual limb evaluation, casting, positive mold rectification, check socket fitting, definitive socket fabrication, and troubleshooting of socket fit. Three hands-on workshops to teach the socket were piloted and attended by 30 certified prosthetists and their patient models. Patient models responded positively to the comfort, range of motion, and stability of the new socket while prosthetists described the technique as "straight forward, reproducible." To our knowledge, this is the first attempt to create a teachable subischial socket, and while it appears promising, more definitive evaluation is needed. Clinical relevance We developed the Northwestern University Flexible Subischial Vacuum (NU-FlexSIV) Socket as a more comfortable alternative to current transfemoral sockets and demonstrated that it could be taught successfully to prosthetists.
Bellnier, David A; Greco, William R; Nava, Hector; Loewen, Gregory M; Oseroff, Allan R; Dougherty, Thomas J
2006-01-01
To measure skin photosensitivity in cancer patients infused with the new second-generation photodynamic sensitizer Photochlor (2-[1-hexyloxyethyl]-2-devinyl pyropheophorbide-a). A major disadvantage of using the clinically approved photosensitizer Photofrin is potentially prolonged and sometimes severe cutaneous phototoxicity. Forty-eight patients enrolled in Phases 1 and 2 clinical trials underwent two or more exposures to four graded doses (44.4, 66.6, 88.8 or 133.2 J/cm2) of artificial solar-spectrum light (SSL) before and after administration of Photochlor at a dose of 2.5, 3, 4, 5 or 6 mg/m2 . The most severe skin response, experienced by only six of the subjects, was limited to erythema without edema and could only be elicited by exposure to the highest light dose. Conversely, eight subjects had no discernible reaction to SSL at any light dose. For nearly all the patients, the peak skin response was obtained when the interval between sensitizer injection and exposure to SSL was 1 day and, generally, their sensitivity to SSL decreased with increasing sensitizer-light interval. For example, a 2-day sensitizer-SSL interval resulted in less severe reactions than those obtained with the 1-day interval in 79% of the subjects, while 90% of the subjects exposed to SSL 3 days after Photochlor infusion had responses that were less severe than those obtained with either the 1- or 2-day sensitizer-SSL interval. Photochlor, at clinically effective antitumor doses, causes only mild skin photosensitivity that declines rapidly over a few days.
Prosthetics socket that incorporates an air splint system focusing on dynamic interface pressure.
Razak, Nasrul Anuar Abd; Osman, Noor Azuan Abu; Gholizadeh, Hossein; Ali, Sadeeq
2014-08-01
The interface pressure between the residual limb and prosthetic socket has a significant effect on an amputee's satisfaction and comfort. This paper presents the design and performance of a new prosthetic socket that uses an air splint system. The air splint prosthetic socket system was implemented by combining the air splint with a pressure sensor that the transhumeral user controls through the use of a microcontroller. The modular construction of the system developed allows the FSR pressure sensors that are placed inside the air splint socket to determine the required size and fitting for the socket used. Fifteen transhumeral amputees participated in the study. The subject's dynamic pressure on the socket that's applied while wearing the air splint systems was recorded using F-socket transducers and microcontroller analysis. The values collected by the F-socket sensor for the air splint prosthetic socket system were determined accordingly by comparing the dynamic pressure applied using statically socket. The pressure volume of the air splint fluctuated and was recorded at an average of 38 kPa (2.5) to 41 kPa (1.3) over three hours. The air splint socket might reduce the pressure within the interface of residual limb. This is particularly important during the daily life activities and may reduce the pain and discomfort at the residual limb in comparison to the static socket. The potential development of an auto-adjusted socket that uses an air splint system as the prosthetic socket will be of interest to researchers involved in rehabilitation engineering, prosthetics and orthotics.
Prosthetics socket that incorporates an air splint system focusing on dynamic interface pressure
2014-01-01
Background The interface pressure between the residual limb and prosthetic socket has a significant effect on an amputee’s satisfaction and comfort. This paper presents the design and performance of a new prosthetic socket that uses an air splint system. Methods The air splint prosthetic socket system was implemented by combining the air splint with a pressure sensor that the transhumeral user controls through the use of a microcontroller. The modular construction of the system developed allows the FSR pressure sensors that are placed inside the air splint socket to determine the required size and fitting for the socket used. Fifteen transhumeral amputees participated in the study. Results The subject’s dynamic pressure on the socket that’s applied while wearing the air splint systems was recorded using F-socket transducers and microcontroller analysis. The values collected by the F-socket sensor for the air splint prosthetic socket system were determined accordingly by comparing the dynamic pressure applied using statically socket. The pressure volume of the air splint fluctuated and was recorded at an average of 38 kPa (2.5) to 41 kPa (1.3) over three hours. Conclusion The air splint socket might reduce the pressure within the interface of residual limb. This is particularly important during the daily life activities and may reduce the pain and discomfort at the residual limb in comparison to the static socket. The potential development of an auto-adjusted socket that uses an air splint system as the prosthetic socket will be of interest to researchers involved in rehabilitation engineering, prosthetics and orthotics. PMID:25085005
Kung, Limin; Smith, Megan L; Benjamim da Silva, Erica; Windle, Michelle C; da Silva, Thiago C; Polukis, Stephanie A
2018-04-11
We evaluated the effectiveness of an additive comprising sodium benzoate, potassium sorbate, and sodium nitrite (SSL) as active ingredients for its ability to improve the aerobic stability of corn silages made in North America. In experiment 1, treatment with SSL (1.5 and 2.0 L/t) on whole-plant corn (WPC) was compared with treatment with an additive containing buffered propionic acid and citric acid (BPA; 2 L/t) on corn harvested at 32 and 38% DM and ensiled for 120 d. Silage treated with BPA was higher in ammonia-N and propionic acid relative to other treatments. Treatments with all of the additives had numerically, but not statistically, fewer yeasts compared with untreated silage. Both application rates of SSL resulted in lower concentrations of ethanol compared with untreated and BPA silages. Treatment with BPA improved the aerobic stability of silages compared with untreated silage, but the effect from SSL was markedly greater. In experiment 2, WPC was untreated or treated with 2 or 3 L of SSL/t or a microbial inoculant containing Enterococcus faecium M74, Lactobacillus plantarum CH6072, and Lactobacillus buchneri LN1819 (final total lactic acid bacteria application rate of 150,000 cfu/g of fresh forage). Silages were air stressed for 24 h at 28 and 42 d of storage and ensiled for 49 d before opening. Inoculation had no effect on acid end products, ethanol, number of yeasts, or aerobic stability compared with other treatments. Treatment with SSL decreased the amount of ethanol, had no effect on number of yeasts, and improved aerobic stability in a dose-dependent manner compared with other treatments. In experiment 3, WPC was untreated or treated with 2 L of SSL/t and ensiled for 5, 15, and 30 d. Treatment with SSL resulted in silage with fewer yeasts and lower concentrations of ethanol after all times of ensiling compared with untreated silage. In addition, SSL improved aerobic stability after each period of ensiling, but the effect was more at 15 and 30 d compared with 5 d of storage. Treating WPC with SSL can improve the aerobic stability of corn silage made in North America, and the effect can be observed as soon as 5 d after ensiling. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
29 CFR Appendix II to Part 1918 - Tables for Selected Miscellaneous Auxiliary Gear (Mandatory)
Code of Federal Regulations, 2010 CFR
2010-07-01
... (IWRC), use vales in HT (FC) columns. MS=Mechanical Splice. S=Poured Socket or Swaged Socket. Note: (1... HT columns of Table 3. MS=Mechanical Splice. S=Poured Socket or Swaged Socket. Notes: (1) These... values in HT columns of Table 3. MS=Mechanical Splice. S=Poured Socket or Swaged Socket. Note: (1) These...
29 CFR Appendix II to Part 1918 - Tables for Selected Miscellaneous Auxiliary Gear (Mandatory)
Code of Federal Regulations, 2014 CFR
2014-07-01
... (IWRC), use vales in HT (FC) columns. MS=Mechanical Splice. S=Poured Socket or Swaged Socket. Note: (1... HT columns of Table 3. MS=Mechanical Splice. S=Poured Socket or Swaged Socket. Notes: (1) These... values in HT columns of Table 3. MS=Mechanical Splice. S=Poured Socket or Swaged Socket. Note: (1) These...
29 CFR Appendix II to Part 1918 - Tables for Selected Miscellaneous Auxiliary Gear (Mandatory)
Code of Federal Regulations, 2012 CFR
2012-07-01
... (IWRC), use vales in HT (FC) columns. MS=Mechanical Splice. S=Poured Socket or Swaged Socket. Note: (1... HT columns of Table 3. MS=Mechanical Splice. S=Poured Socket or Swaged Socket. Notes: (1) These... values in HT columns of Table 3. MS=Mechanical Splice. S=Poured Socket or Swaged Socket. Note: (1) These...
29 CFR Appendix II to Part 1918 - Tables for Selected Miscellaneous Auxiliary Gear (Mandatory)
Code of Federal Regulations, 2011 CFR
2011-07-01
... (IWRC), use vales in HT (FC) columns. MS=Mechanical Splice. S=Poured Socket or Swaged Socket. Note: (1... HT columns of Table 3. MS=Mechanical Splice. S=Poured Socket or Swaged Socket. Notes: (1) These... values in HT columns of Table 3. MS=Mechanical Splice. S=Poured Socket or Swaged Socket. Note: (1) These...
29 CFR Appendix II to Part 1918 - Tables for Selected Miscellaneous Auxiliary Gear (Mandatory)
Code of Federal Regulations, 2013 CFR
2013-07-01
... (IWRC), use vales in HT (FC) columns. MS=Mechanical Splice. S=Poured Socket or Swaged Socket. Note: (1... HT columns of Table 3. MS=Mechanical Splice. S=Poured Socket or Swaged Socket. Notes: (1) These... values in HT columns of Table 3. MS=Mechanical Splice. S=Poured Socket or Swaged Socket. Note: (1) These...
NASA Astrophysics Data System (ADS)
Yano, Ryosuke; Matsumoto, Jun; Suzuki, Kojiro
2011-06-01
Thermally relativistic flow with dissipation was analyzed by solving the rarefied supersonic flow of thermally relativistic matter around a triangle prism by Yano and Suzuki [Phys. Rev. DPRVDAQ1550-7998 83, 023517 (2011)10.1103/PhysRevD.83.023517], where the Anderson-Witting (AW) model was used as a solver. In this paper, we solve the same problem, which was analyzed by Yano and Suzuki, using the relativistic Boltzmann equation (RBE). To solve the RBE, the conventional direct simulation Monte Carlo method for the nonrelativistic Boltzmann equation is extended to a new direct simulation Monte Carlo method for the RBE. Additionally, we solve the modified Marle (MM) model proposed by Yano-Suzuki-Kuroda for comparisons. The solution of the thermally relativistic shock layer around the triangle prism obtained using the relativistic Boltzmann equation is considered by focusing on profiles of macroscopic quantities, such as the density, velocity, temperature, heat flux and dynamic pressure along the stagnation streamline (SSL). Differences among profiles of the number density, velocity and temperature along the SSL obtained using the RBE, the AW and MM. models are described in the framework of the relativistic Navier-Stokes-Fourier law. Finally, distribution functions on the SSL obtained using the RBE are compared with those obtained using the AW and MM models. The distribution function inside the shock wave obtained using the RBE does not indicate a bimodal form, which is obtained using the AW and MM models, but a smooth deceleration of thermally relativistic matter inside a shock wave.
Contour changes in human alveolar bone following tooth extraction of the maxillary central incisor.
Li, Bei; Wang, Yao
2014-12-01
The purpose of this study was to apply cone-beam computed tomography (CBCT) to observe contour changes in human alveolar bone after tooth extraction of the maxillary central incisor and to provide original morphological evidence for aesthetic implant treatment in the maxillary anterior area. Forty patients were recruited into the study. Each patient had two CBCT scans (CBCT I and CBCT II), one taken before and one taken three months after tooth extraction of maxillary central incisor (test tooth T). A fixed anatomic reference point was used to orient the starting axial slice of the two scans. On three CBCT I axial slices, which represented the deep, middle, and shallow layers of the socket, labial and palatal alveolar bone widths of T were measured. The number of sagittal slices from the start point to the pulp centre of T was recorded. On three CBCT II axial slices, the pulp centres of extracted T were oriented according to the number of moved sagittal slices recorded in CBCT I. Labial and palatal alveolar bone widths at the oriented sites were measured. On the CBCT I axial slice which represented the middle layer of the socket, sagittal slices were reconstructed. Relevant distances of T on the sagittal slice were measured, as were the alveolar bone width and tooth length of the opposite central incisor. On the CBCT II axial slice, which represented the middle layer of the socket, relevant distances recorded in CBCT I were transferred on the sagittal slice. The height reduction of alveolar bone on labial and palatal sides was measured, as were the alveolar bone width and tooth length of the opposite central incisor at the oriented site. Intraobserver reliability assessed by intraclass correlation coefficients (ICCs) was high. Paired sample t-tests were performed. The alveolar bone width and tooth length of the opposite central incisor showed no statistical differences (P<0.05). The labial alveolar bone widths of T at the deep, middle, and shallow layers all showed statistical differences. However, no palatal alveolar bone widths showed any statistical differences. The width reduction of alveolar bone was 1.2, 1.6, and 2.7 mm at the deep, middle, and shallow layers, respectively. The height reduction of alveolar bone on labial and palatal sides of T both showed statistical differences, which was 1.9 and 1.1 mm, respectively.
Temperature measurement and control system for transtibial prostheses: Functional evaluation.
Ghoseiri, Kamiar; Zheng, Yong Ping; Leung, Aaron K L; Rahgozar, Mehdi; Aminian, Gholamreza; Lee, Tat Hing; Safari, Mohammad Reza
2018-01-01
The accumulation of heat inside the prosthetic socket increases skin temperature and fosters perspiration, which consequently leads to high tissue stress, friction blister, discomfort, unpleasant odor, and decreased prosthesis suspension and use. In the present study, the prototype of a temperature measurement and control (TM&C) system was designed, fabricated, and functionally evaluated in a phantom model of the transtibial prosthetic socket. The TM&C system was comprised of 12 thermistors divided equally into two groups that arranged internal and external to a prosthetic silicone liner. Its control system was programmed to select the required heating or cooling function of a thermal pump to provide thermal equilibrium based on the amount of temperature difference from a defined set temperature, or the amount of difference between the mean temperature recorded by inside and outside thermistors. A thin layer of aluminum was used for thermal conduction between the thermal pump and different sites around the silicone liner. The results showed functionality of the TM&C system for thermoregulation inside the prosthetic socket. However, enhancing the structure of this TM&C system, increasing its thermal power, and decreasing its weight and cost are main priorities before further development.
NASA Astrophysics Data System (ADS)
Basnet, K.; Constantinescu, G.
2017-11-01
High-resolution, 3-D large eddy simulations are conducted to study the physics of flow past 2-D solid and porous vertical plates of height H mounted on a horizontal surface (no bottom gap) with a fully developed, turbulent incoming flow. The porous plate consists of an array of spanwise-oriented, identical solid cylinders of rectangular cross section. The height of the solid cylinders and the spacing between the solid cylinders, corresponding to the plate's "holes," are kept constant for any given configuration, as the present study considers only plates of uniform porosity. The paper discusses how the mean flow and turbulence structure around the vertical plate, the unsteady forces acting on the plate, the dynamics of the large-scale turbulent eddies, the spectral content of the wake, and the distribution of the bed friction velocity on the horizontal channel bed vary as a function of the plate porosity (0% < P < 36%), the relative spacing between the solid elements of the porous plate (d/H), and the roughness of the channel bed surface. Simulation results are used to explain how the bleeding flow affects the dynamics on the larger billow eddies advected in the separated shear layer (SSL) forming at the top of the plate and the wake structure. It is found that the main recirculation eddy in the wake remains attached to the plate for P < 30%. For larger porosities, the main recirculation eddy forms away from the porous plate. The energy of the billows advected in the SSL decays monotonically with increasing plate porosity. For cases when the recirculation eddy remains attached to the plate, the larger billows advected in the downstream part of the SSL are partially reinjected inside the main recirculation eddy as a result of their interaction with the channel bed. This creates a feedback mechanism that induces large-scale disturbances of the spanwise-oriented vortex tubes advected inside the upstream part of the SSL. Results also show that the mean drag coefficient and the root-mean-square of the drag coefficient fluctuations increase mildly with increasing d/H. Meanwhile, varying d/H has a negligible effect on the position and size of the main recirculation eddy. The presence of large-scale roughness elements (2-D ribs) at the bed results in the decrease of the mean drag coefficient of the plate and, in the case of a solid plate, in a large decrease of the frequency of the large-scale eddies advected in the SSL.
Shallow Scattering Layer (SSL): Emergence Behaviors of Coastal Macrofauna
2003-09-30
group ascent and descent speeds were slower than those found in a deeper water column in Puget Sound by Kringel et al. ( 2003) despite the order...instruments separated by 50 m show high coherence, but they were collected at the same water depth. Our initial data record for West Sound , Orcas Island...West Sound , Orcas Island, Washington Volume backscattering strength at 265 kHz (dB) H ei g h t ab o v e T A P S ( m ) 0 0 10 20 midnight midnight
2009-06-06
written in Standard ML, and comprises nearly 7,000 lines of code. OpenSSL is used for all cryptographic operations. Because the front end tools are used...be managed. Macrobenchmarks. To understand the performance of PCFS in practice, we also ran two simple macrobenchmarks. The first (called OpenSSL in...the table below), untars the OpenSSL source code, compiles it and deletes it. The other (called Fuse in the table below), performs similar operations
Electrical grounding prong socket
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leong, R.
1990-01-01
The invention is a socket for a grounding prong used in a three prong electrical plug and a receptacle for the three prong plug. The socket being sufficiently spacious to prevent the socket from significantly stretching when a larger, U-shaped grounding prong is inserted into the socket, and having a ridge to allow a snug fit when a smaller tubular shape grounding prong is inserted into the socket. 17 figs.
Electrical grounding prong socket
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leong, R.
1990-12-31
The invention is a socket for a grounding prong used in a three prong electrical plug and a receptacle for the three prong plug. The socket being sufficiently spacious to prevent the socket from significantly stretching when a larger, U-shaped grounding prong is inserted into the socket, and having a ridge to allow a snug fit when a smaller tubular shape grounding prong is inserted into the socket. 17 figs.
Electrical grounding prong socket
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leong, R.
1991-06-18
This patent describes a socket for a grounding prong used in a three prong electrical plug and a receptacle for the three prong plug. The socket being sufficiently spacious to prevent the socket from significantly stretching when a larger, U-shaped grounding prong is inserted into the socket, and having a ridge to allow a snug fit when a smaller tubular shape grounding prong is inserted into the socket.
Electrical grounding prong socket
Leong, Robert
1991-01-01
The invention is a socket for a grounding prong used in a three prong electrical plug and a receptacle for the three prong plug. The socket being sufficiently spacious to prevent the socket from significantly stretching when a larger, U-shaped grounding prong is inserted into the socket, and having a ridge to allow a snug fit when a smaller tubular shape grounding prong is inserted into the socket.
Wernke, Matthew M; Schroeder, Ryan M; Haynes, Michael L; Nolt, Lonnie L; Albury, Alexander W; Colvin, James M
2017-07-01
Objective: Prosthetic sockets are custom made for each amputee, yet there are no quantitative tools to determine the appropriateness of socket fit. Ensuring a proper socket fit can have significant effects on the health of residual limb soft tissues and overall function and acceptance of the prosthetic limb. Previous work found that elevated vacuum pressure data can detect movement between the residual limb and the prosthetic socket; however, the correlation between the two was specific to each user. The overall objective of this work is to determine the relationship between elevated vacuum pressure deviations and prosthetic socket fit. Approach: A tension compression machine was used to apply repeated controlled forces onto a residual limb model with sockets of different internal volume. Results: The vacuum pressure-displacement relationship was dependent on socket fit. The vacuum pressure data were sensitive enough to detect differences of 1.5% global volume and can likely detect differences even smaller. Limb motion was reduced as surface area of contact between the limb model and socket was maximized. Innovation: The results suggest that elevated vacuum pressure data provide information to quantify socket fit. Conclusions: This study provides evidence that the use of elevated vacuum pressure data may provide a method for prosthetists to quantify and monitor socket fit. Future studies should investigate the relationship between socket fit, limb motion, and limb health to define optimal socket fit parameters.
Comparison of Rectified and Unrectified Sockets for Transtibial Amputees.
Engsberg, Jack R; Sprouse, S Wayne; Uhrich, Mary L; Ziegler, Barbara R; Luitjohan, F Daniel
2008-01-01
The current method for fabricating prosthetic sockets is to modify a positive mold to account for the non-homogeneity of the residual limb to tolerate load (i.e., rectified socket). We tested unrectified sockets by retaining the shape of the residual limb, except for a distal end pad, using an alginate gel process instead of casting. This investigation compared rectified and unrectified sockets. Forty-three adults with unilateral transtibial amputations were tested after randomly wearing both rectified and unrectified sockets for at least 4 weeks. Testing included a gait analysis, energy expenditure and Prosthesis Evaluation Questionnaire (PEQ). Results indicated no differences between sockets for gait speed and timing, gait kinematics and kinetics, and gait energy expenditure. There were also no differences in the Prosthetic Evaluation Questionnaire and 16 subjects selected the rectified socket, 25 selected the unrectified socket, and 2 subjects selected to use both sockets as their exit socket. Results seemed to indicate that more than one paradigm exists for shaping prosthetic sockets, and this paradigm may be helpful in understanding the mechanisms of socket fit. The alginate gel fabrication method was simpler than the traditional method. The method could be helpful in other countries where prosthetic care is lacking, may be helpful with new amputees, and may be helpful in typical clinics to reduce costs and free the prosthetist to focus more time on patient needs.
Comparison of Rectified and Unrectified Sockets for Transtibial Amputees
Engsberg, Jack R.; Sprouse, S. Wayne; Uhrich, Mary L.; Ziegler, Barbara R.; Luitjohan, F. Daniel
2008-01-01
The current method for fabricating prosthetic sockets is to modify a positive mold to account for the non-homogeneity of the residual limb to tolerate load (i.e., rectified socket). We tested unrectified sockets by retaining the shape of the residual limb, except for a distal end pad, using an alginate gel process instead of casting. This investigation compared rectified and unrectified sockets. Forty-three adults with unilateral transtibial amputations were tested after randomly wearing both rectified and unrectified sockets for at least 4 weeks. Testing included a gait analysis, energy expenditure and Prosthesis Evaluation Questionnaire (PEQ). Results indicated no differences between sockets for gait speed and timing, gait kinematics and kinetics, and gait energy expenditure. There were also no differences in the Prosthetic Evaluation Questionnaire and 16 subjects selected the rectified socket, 25 selected the unrectified socket, and 2 subjects selected to use both sockets as their exit socket. Results seemed to indicate that more than one paradigm exists for shaping prosthetic sockets, and this paradigm may be helpful in understanding the mechanisms of socket fit. The alginate gel fabrication method was simpler than the traditional method. The method could be helpful in other countries where prosthetic care is lacking, may be helpful with new amputees, and may be helpful in typical clinics to reduce costs and free the prosthetist to focus more time on patient needs. PMID:18776945
Change in residual limb size over time in the NU-FlexSIV socket: A case study.
Fatone, Stefania; Yohay, Jessica; Caldwell, Ryan
2018-05-01
This case study represented a unique opportunity wherein a long-time user of sub-ischial sockets had kept nearly every socket he wore for a decade. This individual let us borrow these sockets so we could digitize them and indirectly assess change in residual limb size over time by calculating changes in socket volume and circumferences over time. Case Description and Methods: Over a decade, the subject maintained a relatively stable body weight of 84-88 kg and received nine sub-ischial sockets. The internal surface of each socket was scanned using a mechanical digitizer and volume and circumferences calculated. Findings and Outcomes: Socket volume increased 31.3%, from a low of 2659.2 cm 3 for the oldest socket to a high of 3490.6 cm 3 for the most recent socket. Proximal circumferences increased more than distal circumferences with a 15.9% total increase proximally versus 8.9% total increase distally. The results suggest that this individual's residual limb increased in size over time despite the compressive effect of the socket and liner. In addition, the increase in circumference was greater proximally than distally, which is where the remaining muscle bellies are located. Clinical relevance This case study provides insight into the long-term effect of the sub-ischial socket on residual limb volume given compression of the soft tissues by the socket system.
Fatone, Stefania; Caldwell, Ryan
2017-01-01
Background: Current transfemoral prosthetic sockets restrict function, lack comfort, and cause residual limb problems. Lower proximal trim lines are an appealing way to address this problem. Development of a more comfortable and possibly functional subischial socket may contribute to improving quality of life of persons with transfemoral amputation. Objectives: The purpose of this study was to (1) describe the design and fabrication of a new subischial socket and (2) describe efforts to teach this technique. Study design: Development project. Methods: Socket development involved defining the following: subject and liner selection, residual limb evaluation, casting, positive mold rectification, check socket fitting, definitive socket fabrication, and troubleshooting of socket fit. Three hands-on workshops to teach the socket were piloted and attended by 30 certified prosthetists and their patient models. Results: Patient models responded positively to the comfort, range of motion, and stability of the new socket while prosthetists described the technique as “straight forward, reproducible.” Conclusion: To our knowledge, this is the first attempt to create a teachable subischial socket, and while it appears promising, more definitive evaluation is needed. Clinical relevance We developed the Northwestern University Flexible Subischial Vacuum (NU-FlexSIV) Socket as a more comfortable alternative to current transfemoral sockets and demonstrated that it could be taught successfully to prosthetists. PMID:28094686
The role of gravity in the nutrition and formation of Bacillus colonies
NASA Astrophysics Data System (ADS)
Puzyr, A.; Tirranen, L.; Krylova, T.
The soil-like substrate is used to cultivate higher plants in man-made closed ecosystems. It allows increasing the closeness of the systems and decreasing the plant solid residues and human wastes. Unusual funnel-shaped bacterial colonies of Bacillus species have been observed during analysis of microflora of plant nutritional solution. The colonies have the following characteristics: a) the diameter of "funnel socket" (the biomass contacting with nutritional agar) is 10.0-15.0 mm; b) the thickness of "funnel socket" is 0.5-2.5 mm; c) the diameter of the middle part of the "funnel spout" (the biomass contacting with the gas phase) is 1,0-1,5 mm; d) the length of the "funnel spout" is 10.0-15.0 mm. In the socket and the middle part of the "funnel spout" there is a gas cavity which is most probably formed by bacterial gas metabolites. It has been shown that: i) the surface of these funnel-shaped colonies of Bacillus species is hydrophobic, as is the surface of other Bacillus species ( . brevis, B. cellulomonos, B. flavus, B.B formosus, B. subtilis); ii) the forms of colonies can be changed by varying the position of the growing biomass in relation to the gravitation forces. The experiment proved that the form of the "funnel sockets" and the length of the "funnel spouts" of the colonies are determined by hydrophobic air-contacting surface layer, which does not leak and stretches under the weight of accumulated water. A hypothesis has been suggested that the gravity force plays the role of a "pump" supplying and holding water within the colony. Thus, the water that comes under the gravity force contains dissolved nutrients and bacterial cells in the hydrophobic layer. These cells that are situated far away from the nutrient agar have no nutrient deficiency. The water accumulated by the colonies might be free water of agar media or it can be produced by metabolic disruption of medium fat. Hence, when growing a colony in agar media the water-soluble nutrient substances enter the growing colonies not only due to diffusion processes but also with the directional water flow under the gravity force.
Review of the socket design and interface pressure measurement for transtibial prosthesis.
Pirouzi, Gh; Abu Osman, N A; Eshraghi, A; Ali, S; Gholizadeh, H; Wan Abas, W A B
2014-01-01
Socket is an important part of every prosthetic limb as an interface between the residual limb and prosthetic components. Biomechanics of socket-residual limb interface, especially the pressure and force distribution, have effect on patient satisfaction and function. This paper aimed to review and evaluate studies conducted in the last decades on the design of socket, in-socket interface pressure measurement, and socket biomechanics. Literature was searched to find related keywords with transtibial amputation, socket-residual limb interface, socket measurement, socket design, modeling, computational modeling, and suspension system. In accordance with the selection criteria, 19 articles were selected for further analysis. It was revealed that pressure and stress have been studied in the last decaeds, but quantitative evaluations remain inapplicable in clinical settings. This study also illustrates prevailing systems, which may facilitate improvements in socket design for improved quality of life for individuals ambulating with transtibial prosthesis. It is hoped that the review will better facilitate the understanding and determine the clinical relevance of quantitative evaluations.
Review of the Socket Design and Interface Pressure Measurement for Transtibial Prosthesis
Pirouzi, Gh.; Abu Osman, N. A.; Eshraghi, A.; Ali, S.; Gholizadeh, H.; Wan Abas, W. A. B.
2014-01-01
Socket is an important part of every prosthetic limb as an interface between the residual limb and prosthetic components. Biomechanics of socket-residual limb interface, especially the pressure and force distribution, have effect on patient satisfaction and function. This paper aimed to review and evaluate studies conducted in the last decades on the design of socket, in-socket interface pressure measurement, and socket biomechanics. Literature was searched to find related keywords with transtibial amputation, socket-residual limb interface, socket measurement, socket design, modeling, computational modeling, and suspension system. In accordance with the selection criteria, 19 articles were selected for further analysis. It was revealed that pressure and stress have been studied in the last decaeds, but quantitative evaluations remain inapplicable in clinical settings. This study also illustrates prevailing systems, which may facilitate improvements in socket design for improved quality of life for individuals ambulating with transtibial prosthesis. It is hoped that the review will better facilitate the understanding and determine the clinical relevance of quantitative evaluations. PMID:25197716
Safari, Mohammad Reza; Tafti, Nahid; Aminian, Gholamreza
2015-01-01
The objectives of the current study were to compare intra-socket pressure differences between comfortable and uncomfortable socket conditions, and the usefulness of subject perception of satisfaction, activity limitations, and socket comfort in distinguishing between these two socket conditions. Five unilateral trans-tibial amputees took part in the study. They answered the Socket Comfort Score (SCS) and Trinity Amputation and Prosthetic Experience Scale (TAPES) questionnaires before the interface pressure (in standing and walking) was measured for the uncomfortable socket condition at five regions of the residual limb. Participants were then provided with a comfortable socket and wore it for two weeks. Participants who were satisfied with the socket fit after two weeks repeated the SCS and TAPES questionnaires and interface pressure measurements. The differences between the test results of the two conditions were not statistically significant, except for the interface pressure at the popliteal region during the early stance phase, TAPES socket fit subscale, and the SCS. Due to large variability of the data and the lack of statistical significance, no firm conclusion can be made on the possible relationship between the interface pressure values and the patient-reported outcomes of the two socket conditions. A larger sample size and longer acclimation period are required to locate significant differences.
Co-Labeling for Multi-View Weakly Labeled Learning.
Xu, Xinxing; Li, Wen; Xu, Dong; Tsang, Ivor W
2016-06-01
It is often expensive and time consuming to collect labeled training samples in many real-world applications. To reduce human effort on annotating training samples, many machine learning techniques (e.g., semi-supervised learning (SSL), multi-instance learning (MIL), etc.) have been studied to exploit weakly labeled training samples. Meanwhile, when the training data is represented with multiple types of features, many multi-view learning methods have shown that classifiers trained on different views can help each other to better utilize the unlabeled training samples for the SSL task. In this paper, we study a new learning problem called multi-view weakly labeled learning, in which we aim to develop a unified approach to learn robust classifiers by effectively utilizing different types of weakly labeled multi-view data from a broad range of tasks including SSL, MIL and relative outlier detection (ROD). We propose an effective approach called co-labeling to solve the multi-view weakly labeled learning problem. Specifically, we model the learning problem on each view as a weakly labeled learning problem, which aims to learn an optimal classifier from a set of pseudo-label vectors generated by using the classifiers trained from other views. Unlike traditional co-training approaches using a single pseudo-label vector for training each classifier, our co-labeling approach explores different strategies to utilize the predictions from different views, biases and iterations for generating the pseudo-label vectors, making our approach more robust for real-world applications. Moreover, to further improve the weakly labeled learning on each view, we also exploit the inherent group structure in the pseudo-label vectors generated from different strategies, which leads to a new multi-layer multiple kernel learning problem. Promising results for text-based image retrieval on the NUS-WIDE dataset as well as news classification and text categorization on several real-world multi-view datasets clearly demonstrate that our proposed co-labeling approach achieves state-of-the-art performance for various multi-view weakly labeled learning problems including multi-view SSL, multi-view MIL and multi-view ROD.
Wei, Liangliang; Li, Siliang; Noguera, Daniel R; Qin, Kena; Jiang, Junqiu; Zhao, Qingliang; Kong, Xiangjuan; Cui, Fuyi
2015-06-01
Recycling wastewater treatment plant (WWTP) effluent at low cost via the soil aquifer treatment (SAT), which has been considered as a renewable approach in regenerating potable and non-potable water, is welcome in arid and semi-arid regions throughout the world. In this study, the effect of a coal slag additive on the bulk removal of the dissolved organic matter (DOM) in WWTP effluent during SAT operation was explored via the matrix configurations of both coal slag layer and natural soil layer. Azide inhibition and XAD-resins fractionation experiments indicated that the appropriate configuration designing of an upper soil layer (25 cm) and a mixture of soil/coal slag underneath would enhance the removal efficiency of adsorption and anaerobic biodegradation to the same level as that of aerobic biodegradation (31.7% vs 32.2%), while it was only 29.4% compared with the aerobic biodegradation during traditional 50 cm soil column operation. The added coal slag would preferentially adsorb the hydrophobic DOM, and those adsorbed organics could be partially biodegraded by the biomass within the SAT systems. Compared with the relatively lower dissolved organic carbon (DOC), ultraviolet light adsorption at 254 nm (UV-254) and trihalomethane formation potential (THMFP) removal rate of the original soil column (42.0%, 32.9%, and 28.0%, respectively), SSL2 and SSL4 columns would enhance the bulk removal efficiency to more than 60%. Moreover, a coal slag additive in the SAT columns could decline the aromatic components (fulvic-like organics and tryptophan-like proteins) significantly. Copyright © 2015 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, E.; Prakash, L.; Guzder, S.N.
1992-12-01
Xeroderma pigmentosum (XP) patients are extremely sensitive to ultraviolet (UV) light and suffer from a high incidence of skin cancers, due to a defect in nucleotide excision repair. The disease is genetically heterogeneous, and seven complementation groups, A-G, have been identified. Homologs of human excision repair genes ERCC1, XPDC/ERCC2, and XPAC have been identified in the yeast Saccharomyces cerevisiae. Since no homolog of human XPBC/ERCC3 existed among the known yeast genes, we cloned the yeast homolog by using XPBC cDNA as a hybridization probe. The yeast homolog, RAD25 (SSL2), encodes a protein of 843 amino acids (M[sub r] 95,356). Themore » RAD25 (SSL2)- and XPCX-encoded proteins share 55% identical and 72% conserved amino acid residues, and the two proteins resemble one another in containing the conserved DNA helicase sequence motifs. A nonsense mutation at codon 799 that deletes the 45 C-terminal amino acid residues in RAD25 (SSL2) confers UV sensitivity. This mutation shows epistasis with genes in the excision repair group, whereas a synergistic increase in UN sensitivity occurs when it is combined with mutations in genes in other DNA repair pathways, indicating that RAD25 (SSL2) functions in excision repair but not in other repair pathways. We also show that RAD25 (SSL2) is an essential gene. A mutation of the Lys[sup 392] residue to arginine in the conserved Walker type A nucleotide-binding motif is lethal, suggesting an essential role of the putative RAD 25 (SSL2) ATPase/DNA helicase activity in viability. 40 refs., 3 figs., 1 tab.« less
Kalmykova, Alla I.; Shevelyov, Yury Y.; Dobritsa, Anna A.; Gvozdev, Vladimir A.
1997-01-01
The acquisition of autosomal fertility genes has been proposed to be an important process in human Y chromosome evolution. For example, the Y-linked fertility factor DAZ (Deleted in Azoospermia) appears to have arisen after the transposition and tandem amplification of the autosomal DAZH gene. The Drosophila melanogaster Y chromosome contains tandemly repeated Su(Ste) units that are thought to affect male fertility as suppressors of the homologous X-linked Stellate repeats. Here we report the detection of a testis-expressed autosomal gene, SSL [Su(Ste)-like], that appears to be an ancestor of the Y-linked Su(Ste) units. SSL encodes a casein kinase 2 (CK2) β-subunit-like protein. Its putative ORF shares extensive (45%) homology with the genuine β-subunit of CK2 and retains the conserved C-terminal and Glu/Asp-rich domains that are essential for CK2 holoenzyme regulation. SSL maps within region 60D1–2 of D. melanogaster and D. simulans polytene chromosomes. We present evidence that SSL was derived from the genuine βCK2 gene by reverse transcription. This event resulted in the loss of the first three introns in the coding region of the SSL ancestor gene. Evolutionary analysis indicates that SSL has evolved under selective pressure at the translational level. Its sequence, especially in the 3′ region, is much closer to the Y-linked Su(Ste) tandem repeats than to the βCK2 gene. These results suggest that the acquisition of testis-specific autosomal genes may be important for the evolution of Drosophila as well as human Y chromosomes. PMID:9177211
Binary Code Extraction and Interface Identification for Security Applications
2009-10-02
the functions extracted during the end-to-end applications and at the bottom some additional functions extracted from the OpenSSL library. fact that as...mentioned in Section 5.1 through Section 5.3 and some additional functions that we extract from the OpenSSL library for evaluation purposes. The... OpenSSL functions, the false positives and negatives are measured by comparison with the original C source code. For the malware samples, no source is
Modeling the impact of thermal effects on luminous flux maintenance for SSL luminaires
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davis, Lynn; Mills, Karmann; Lamvik, Michael
Meeting the longevity requirements of solid-state lighting (SSL) devices places extreme demands on the materials and designs that are used in SSL luminaires. Therefore, understanding the aging characteristics of lens, reflectors, and other materials is essential to projecting the long-term performance of LED-based lighting systems. Overlooking these factors at either the design or product specification stage can result in premature failure of the device due to poor luminous flux maintenance and/or excessive chromaticity shifts. This paper describes a methodology for performing accelerated stress testing (AST) on materials intended for use in SSL luminaires. This test methodology, which consists of elevatedmore » temperature and humidity conditions, produces accelerated aging data that can be correlated to expected performance under normal luminaire operating conditions. The correlations can then be leveraged to produce models of the changes in the optical properties of key materials including transmittance versus wavelength of lenses and reflectance versus wavelength for housings and other reflectors. This information has been collected into a lumen maintenance decision support tool (LM-DST) and together with user supplied inputs (e.g., expected operation conditions) can provide guidance on lifetime expectations of SSL luminaires. This approach has been applied to a variety of materials commonly found in SSL luminaires including acrylics, polycarbonates, and silicones used for lenses and paints, coatings, films, and composites used for reflectors.« less
Two degree of freedom camera mount
NASA Technical Reports Server (NTRS)
Ambrose, Robert O. (Inventor)
2003-01-01
A two degree of freedom camera mount. The camera mount includes a socket, a ball, a first linkage and a second linkage. The socket includes an interior surface and an opening. The ball is positioned within an interior of the socket. The ball includes a coupling point for rotating the ball relative to the socket and an aperture for mounting a camera. The first and second linkages are rotatably connected to the socket and slidably connected to the coupling point of the ball. Rotation of the linkages with respect to the socket causes the ball to rotate with respect to the socket.
NASA Technical Reports Server (NTRS)
Barry, Matthew R.
2006-01-01
The X-Windows Socket Widget Class ("Class" is used here in the object-oriented-programming sense of the word) was devised to simplify the task of implementing network connections for graphical-user-interface (GUI) computer programs. UNIX Transmission Control Protocol/Internet Protocol (TCP/IP) socket programming libraries require many method calls to configure, operate, and destroy sockets. Most X Windows GUI programs use widget sets or toolkits to facilitate management of complex objects. The widget standards facilitate construction of toolkits and application programs. The X-Windows Socket Widget Class encapsulates UNIX TCP/IP socket-management tasks within the framework of an X Windows widget. Using the widget framework, X Windows GUI programs can treat one or more network socket instances in the same manner as that of other graphical widgets, making it easier to program sockets. Wrapping ISP socket programming libraries inside a widget framework enables a programmer to treat a network interface as though it were a GUI.
Mahesh, Lanka; Narayan, Tv; Kostakis, Georgios; Shukla, Sagrika
2014-03-01
To measure implant stability using periotest values of implants placed in sockets augmented with calcium phospho-silicate putty (CPS Putty) as compared with implant stability in naturally healed sockets. Twenty two sockets were implanted with CPS Putty immediately after extraction. The sockets were re-entered after a healing period at 5 to 6 months (average 5.3 months) for implant placement. Periotest values were recorded during implant insertion to assess primary stability. These were compared with the Periotest values of 26 implants placed in 22 patients, with naturally healed sockets. Periotest values were significantly lower in the grafted group, indicating better implant stability in sites grafted with CPS putty. Implant stability seems to be significantly higher in sockets augmented using CPS putty when compared to nongrafted sites. This suggests that socket grafting with CPS putty may enhance the quality of available bone for implantation.
Gerschutz, Maria J; Haynes, Michael L; Nixon, Derek; Colvin, James M
2012-01-01
A prosthesis encounters loading through forces and torques exerted by the person with amputation. International Organization for Standardization (ISO) standard 10328 was designed to test most lower-limb prosthetic components. However, this standard does not include prosthetic sockets. We measured static failure loads of prosthetic sockets using a modified ISO 10328 and then compared them with the criteria set by this standard for other components. Check socket (CS) strengths were influenced by thickness, material choice, and fabrication method. Copolymer socket (CP) strengths depended on thickness and fabrication methods. A majority of the CSs and all of the CPs failed to pass the ISO 10328 ductile loading criterion. In contrast, the strengths of definitive laminated sockets (DLs) were influenced more by construction material and technique. A majority of the DLs failed to pass the ISO 10328 brittle loading criterion. Analyzing prosthetic sockets from a variety of facilities demonstrated that socket performance varies considerably between and within facilities. The results from this article provide a foundation for understanding the quality of prosthetic sockets, some insight into possible routes for improving the current care delivered to patients, and a comparative basis for future technology.
Wernke, Matthew M.; Schroeder, Ryan M.; Haynes, Michael L.; Nolt, Lonnie L.; Albury, Alexander W.; Colvin, James M.
2017-01-01
Objective: Prosthetic sockets are custom made for each amputee, yet there are no quantitative tools to determine the appropriateness of socket fit. Ensuring a proper socket fit can have significant effects on the health of residual limb soft tissues and overall function and acceptance of the prosthetic limb. Previous work found that elevated vacuum pressure data can detect movement between the residual limb and the prosthetic socket; however, the correlation between the two was specific to each user. The overall objective of this work is to determine the relationship between elevated vacuum pressure deviations and prosthetic socket fit. Approach: A tension compression machine was used to apply repeated controlled forces onto a residual limb model with sockets of different internal volume. Results: The vacuum pressure–displacement relationship was dependent on socket fit. The vacuum pressure data were sensitive enough to detect differences of 1.5% global volume and can likely detect differences even smaller. Limb motion was reduced as surface area of contact between the limb model and socket was maximized. Innovation: The results suggest that elevated vacuum pressure data provide information to quantify socket fit. Conclusions: This study provides evidence that the use of elevated vacuum pressure data may provide a method for prosthetists to quantify and monitor socket fit. Future studies should investigate the relationship between socket fit, limb motion, and limb health to define optimal socket fit parameters. PMID:28736683
Changes in secondary structure of gluten proteins due to emulsifiers
NASA Astrophysics Data System (ADS)
Gómez, Analía V.; Ferrer, Evelina G.; Añón, María C.; Puppo, María C.
2013-02-01
Changes in the secondary structure of gluten proteins due to emulsifiers were analyzed by Raman Spectroscopy. The protein folding induced by 0.25% SSL (Sodium Stearoyl Lactylate) (GS0.25, Gluten + 0.25% SSL) included an increase in α-helix conformation and a decrease in β-sheet, turns and random coil. The same behavior, although in a less degree, was observed for 0.5% gluten-DATEM (Diacetyl Tartaric Acid Esters of Monoglycerides) system. The low burial of Tryptophan residues to a more hydrophobic environment and the low percentage area of the C-H stretching band for GS0.25 (Gluten + 0.25% SSL), could be related to the increased in α-helix conformation. This behavior was also confirmed by changes in stretching vibrational modes of disulfide bridges (S-S) and the low exposure of Tyrosine residues. High levels of SSL (0.5% and 1.0%) and DATEM (1.0%) led to more disordered protein structures, with different gluten networks. SSL (1.0%) formed a more disordered and opened gluten matrix than DATEM, the last one being laminar and homogeneous.
A Sea-Sky Line Detection Method for Unmanned Surface Vehicles Based on Gradient Saliency.
Wang, Bo; Su, Yumin; Wan, Lei
2016-04-15
Special features in real marine environments such as cloud clutter, sea glint and weather conditions always result in various kinds of interference in optical images, which make it very difficult for unmanned surface vehicles (USVs) to detect the sea-sky line (SSL) accurately. To solve this problem a saliency-based SSL detection method is proposed. Through the computation of gradient saliency the line features of SSL are enhanced effectively, while other interference factors are relatively suppressed, and line support regions are obtained by a region growing method on gradient orientation. The SSL identification is achieved according to region contrast, line segment length and orientation features, and optimal state estimation of SSL detection is implemented by introducing a cubature Kalman filter (CKF). In the end, the proposed method is tested on a benchmark dataset from the "XL" USV in a real marine environment, and the experimental results demonstrate that the proposed method is significantly superior to other state-of-the-art methods in terms of accuracy rate and real-time performance, and its accuracy and stability are effectively improved by the CKF.
2016-10-01
satisfaction with device’’ (i.e. prosthesis) than the IC Socket. During year 1, we received all required IRB approvals, registered the clinical... satisfaction with device” (i.e. prosthesis) than the IC Socket. 2. KEYWORDS: Prosthetic Socket, Artificial Limbs, Prosthesis, Transfemoral Amputee, Gait...FlexSIV Socket will result in better quality of life and “ satisfaction with device” (i.e. prosthesis) than the IC socket. Accomplishments under
The management of amputations of the leg using a new rigid foam plaster for prosthetic fitting.
Hölter, W; Echterhoff, M; Blömer, A; Verfürden, H
1980-01-01
This paper describes the use of a rigid polyurethane foam to construct a stump socket for immediate or early prosthetic fitting in 15 patients with amputation through the leg. The foam plaster is poured into a prepared cotton sleeve, with a zip incorporated, and rolled out to a layer 4 mm thick. The filled sleeve is put around the stump and the zip closed, moulding the sleeve firmly to the stump. The closed sleeve hardens into a rigid polyurethane shell within 20 min. Aferwards the skeletal prosthetic components are fixed with the same rigid foam. The polyurethane foam socket is quickly and cleanly prepared, only one third of the weight of a plaster of Paris cast and is easily removed by means of the zip, allowing access to the stump.
Shadow: Running Tor in a Box for Accurate and Efficient Experimentation
2011-09-23
Modeling the speed of a target CPU is done by running an OpenSSL [31] speed test on a real CPU of that type. This provides us with the raw CPU processing...rate, but we are also interested in the processing speed of an application. By running application 5 benchmarks on the same CPU as the OpenSSL speed test...simulation, saving CPU cy- cles on our simulation host machine. Shadow removes cryptographic processing by preloading the main OpenSSL [31] functions used
Protecting Cryptographic Keys and Functions from Malware Attacks
2010-12-01
registers. modifies RSA private key signing in OpenSSL to use the technique. The resulting system has the following features: 1. No special hardware is...the above method based on OpenSSL , by exploiting the Streaming SIMD Extension (SSE) XMM registers of modern Intel and AMD x86-compatible CPU’s [22...one can store a 2048-bit exponent.1 Our prototype is based on OpenSSL 0.9.8e, the Ubuntu 6.06 Linux distribution with a 2.6.15 kernel, and SSE2 which
Hachisuka, K; Matsushima, Y; Ohmine, S; Shitama, H; Shinkoda, K
2001-09-01
The purpose of this study was to examine the moisture permeability properties of materials used for total surface bearing (TSB) socket with a silicone liner, a combination of Silicone Suction Socket or Icelandic Roll-On Silicone Socket (ICEROSS) and an acrylic plastic sheet (Degaplast), patella-tendon bearing (PTB) socket, a combination of Pe-Lite and Degaplast, and wooden socket made of poplar. Moisture permeability of the socket materials was measured as the diminution of water in a container after 12 hours in a climatic chamber. Eight containers with their open, top side were uncovered (no material) or sealed with one of the socket materials; the experiment was repeated four times. One-way analysis of variance followed by Bonferroni's test was applied to examine the differences in moisture permeability. Moisture permeability levels were as follows: no material, 85.9 +/- 1.3 g; poplar, 4.3 +/- 0.4 g; Silicone Suction Socket, 1.1 +/- 0.2 g; ICEROSS, 1.0 +/- 0.2 g; Pe-Lite, 0.8 +/- 0.1 g; 3S + Degaplast, 0.8 +/- 0.1 g; ICEROSS + Degaplast, 0.8 +/- 0.2 g; and Pe-Lite + Degaplast, 0.8 +/- 0.1 g. There were significant differences between the uncovered container and the others, and between poplar and the others (P < 0.05). We concluded that the TSB socket with a silicone liner is not superior to the PTB socket with regard to moisture permeability, and that it is necessary to develop a new prosthetic socket that allows heat release and drainage of sweat.
GATEWAY Demonstrations: Exploring SSL Product Performance in the Real World
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
Fact sheet that outlines DOE's GATEWAY technology demonstration program, which evaluates high-performance SSL products for general illumination in a variety of real-world exterior and interior applications.
Effect of alignment perturbations in a trans-tibial prosthesis user: A pilot study.
Courtney, Anna; Orendurff, Michael S; Buis, Arjan
2016-04-01
A recurring complication in trans-tibial prosthetic limb users is "poor socket fit" with painful residuum-socket interfaces, a consequence of excess pressure. This is due to both poor socket fit and poor socket alignment; however, the interaction of these factors has not been quantified. Through evaluation of kinetic data this study aimed to articulate an interaction uniting socket design, alignment and interface pressures. The results will help to refine future studies and will hopefully help determine whether sockets can be designed, fitted and aligned to maximize mobility whilst minimizing injurious forces. Interface pressures were recorded throughout ambulation in one user with "optimal (reference) alignment" followed by 5 malalignments in a patellar tendon-bearing and a hydrocast socket. Marked differences in pressure distribution were discovered when equating the patellar tendon-bearing against the hydrocast socket and when comparing interface pressures from reference with offset alignment. Patellar tendon-bearing sockets were found to be more sensitive to alignment perturbations than hydrocast sockets. A complex interaction was found, with the most prominent finding demonstrating the requisite for attainment of optimal alignment: a translational alignment error of 10 mm can increase maximum peak pressures by 227% (mean 17.5%). Refinements for future trials are described and the necessity for future research into socket design, alignment and interface pressures has been estabilished.
Alveolar osteitis; Alveolitis; Septic socket ... You may be more at risk for dry socket if you: Have poor oral health Have a ... after having a tooth pulled Have had dry socket in the past Drink from a straw after ...
Healing of ungrafted and grafted extraction sockets after 12 weeks: a prospective clinical study.
Heberer, Susanne; Al-Chawaf, Bassem; Jablonski, Carlo; Nelson, John J; Lage, Hermann; Nelson, Katje
2011-01-01
In this prospective study, bone formation in human extraction sockets augmented with Bio-Oss Collagen after a 12-week healing period was quantified and compared to bone formation in unaugmented extraction sockets. Selected patients with four-walled extraction sockets were included in this prospective study. After extraction, the sockets were randomly augmented using Bio-Oss Collagen or left to heal unfilled without raising a mucoperiosteal flap. At the time of implant placement, histologic specimens were obtained from the socket and analyzed. Statistical analysis was performed using the Wilcoxon signed-rank test. Twenty-five patients with a total of 39 sockets (20 augmented, 19 unaugmented) were included in the study and the histologic specimens analyzed. All specimens were free of inflammatory cells. The mean overall new bone formation in the augmented sites was 25% (range, 8%-41%) and in the unaugmented sockets it was 44% (range, 3%-79%). There was a significant difference in the rate of new bone formation between the grafted and ungrafted sockets and a significant difference in the bone formation rate in the apical compared to the coronal regions of all sockets, independent of the healing mode. This descriptive study demonstrated that bone formation in Bio-Oss Collagen-grafted human extraction sockets was lower than bone formation in ungrafted sockets. Bone formation occurred in all specimens with varying degrees of maturation independent of the grafting material and was initiated from the apical region.
Al-Fakih, Ebrahim A; Abu Osman, Noor Azuan; Mahmad Adikan, Faisal Rafiq
2016-07-20
The distribution of interface stresses between the residual limb and prosthetic socket of a transtibial amputee has been considered as a direct indicator of the socket quality fit and comfort. Therefore, researchers have been very interested in quantifying these interface stresses in order to evaluate the extent of any potential damage caused by the socket to the residual limb tissues. During the past 50 years a variety of measurement techniques have been employed in an effort to identify sites of excessive stresses which may lead to skin breakdown, compare stress distributions in various socket designs, and evaluate interface cushioning and suspension systems, among others. The outcomes of such measurement techniques have contributed to improving the design and fitting of transtibial sockets. This article aims to review the operating principles, advantages, and disadvantages of conventional and emerging techniques used for interface stress measurements inside transtibial sockets. It also reviews and discusses the evolution of different socket concepts and interface stress investigations conducted in the past five decades, providing valuable insights into the latest trends in socket designs and the crucial considerations for effective stress measurement tools that lead to a functional prosthetic socket.
Al-Fakih, Ebrahim A.; Abu Osman, Noor Azuan; Mahmad Adikan, Faisal Rafiq
2016-01-01
The distribution of interface stresses between the residual limb and prosthetic socket of a transtibial amputee has been considered as a direct indicator of the socket quality fit and comfort. Therefore, researchers have been very interested in quantifying these interface stresses in order to evaluate the extent of any potential damage caused by the socket to the residual limb tissues. During the past 50 years a variety of measurement techniques have been employed in an effort to identify sites of excessive stresses which may lead to skin breakdown, compare stress distributions in various socket designs, and evaluate interface cushioning and suspension systems, among others. The outcomes of such measurement techniques have contributed to improving the design and fitting of transtibial sockets. This article aims to review the operating principles, advantages, and disadvantages of conventional and emerging techniques used for interface stress measurements inside transtibial sockets. It also reviews and discusses the evolution of different socket concepts and interface stress investigations conducted in the past five decades, providing valuable insights into the latest trends in socket designs and the crucial considerations for effective stress measurement tools that lead to a functional prosthetic socket. PMID:27447646
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davis, Lynn; Arquit Niederberger, Anne
Abstract— Lighting systems have the ability to transform the economic and educational infrastructure of disadvantaged communities, and eradicating “light poverty” has become one of the primary goals of the International Year of Light 2015. Solid-state lighting (SSL) technology, based on light-emitting diode (LED) light sources, has emerged as the next generation of lighting technology, with a current global market penetration of roughly 5%. This paper will report on recent research on understanding SSL lighting system reliability (failure modes, environmental stressors, electrical power quality); discuss the implications of SSL technology reliability for providing lighting services; and suggest practical approaches to ensuremore » SSL reliability to benefit humanity. Among the key findings from this work is that LED sources can be extremely reliable, withstanding a broad range of environmental stresses without failure. Nonetheless, SSL lighting systems can have a negative impact on electrical power reliability, as well as on the affordability of lighting services, without attention to the quality of the accompanying power infrastructure. It is therefore critical to ensure that the performance of the power supply electronics used in lighting systems is matched to the quality of the power source, when evaluating energy efficient lighting choices.« less
The Ecological Soil Screening Level (Eco-SSL) work group, composed of scientists and risk assessors from EPA, Environment Canada, DOE, Army, Navy, Air Force, states, industry, academia, and consulting companies, has developed scientifically sound, ecologically-based, soil screeni...
Mohd Hawari, Nurhanisah; Jawaid, Mohammad; Md Tahir, Paridah; Azmeer, Raja Ahmad
2017-11-01
The aim of this case study was to explore patient satisfaction with the quality of prosthetic leg sockets intended for persons with lower limb amputations. A qualitative study based on in-depth interviews, preceded by a questionnaire session, was carried out with patients from the Rehabilitation Center and Hospital in Malaysia. Twelve out-patient and in-patient amputees with lower limb amputations, specifically below-knee amputations, were chosen randomly. The analysis of patients' narratives aimed to identify the functional and esthetic characteristics of currently used prosthetic leg sockets and any problems related to them. The obtained results indicated that out of the 12 participants, 41.7% and 25% were satisfied and somewhat satisfied with their current prosthetic sockets. Durability and comfort were rated by the participants as the most important characteristics of prosthetic sockets, with 83.3%. As regards the esthetic appearance of the socket, 66.7% of the respondents considered that the most important feature was the material from which the socket was fabricated. Thus, we conclude that current satisfaction levels with the quality of prosthetic sockets among amputees in Malaysia are suitable, prosthesis being preferred by many amputees. The results can be used to direct future research on cosmesis and functionality of prosthetic socket design. Implications for Rehabilitation Case study will help participants to get cost effective prosthetic leg socket. Develop prosthetic leg socket comfortable as comparative to existing one. Help Malaysian government to make policy to develop local prosthetic leg socket at affordable price.
Kahle, Jason T.; Klenow, Tyler D.; Highsmith, M. Jason
2016-01-01
The socket-limb interface is vital for functionality and provides stability and mobility for the amputee. Volume fluctuation can lead to compromised fit and function. Current socket technology does not accommodate for volume fluctuation. An adjustable interface may improve function and comfort by filling this technology gap. The purpose of this study was to compare the effectiveness of the standard of care (SOC) ischial ramus containment to an adjustable transfemoral prosthetic interface socket in the accommodation of volume fluctuation. A prospective experimental case study using repeated measures of subjective and performance outcome measures between socket conditions was employed. In the baseline volume condition, the adjustable socket improved subjective and performance measures 19% to 37% over SOC, whereas the two-minute walk test demonstrated equivalence. In the volume loss condition, the adjustable socket improved all subjective and performance measures 22% to 93%. All aggregated data improved 16% to 50% compared with the SOC. In simulated volume gain, the SOC socket failed, while the subject was able to complete the protocol using the adjustable socket. In this case study, the SOC socket was inferior to the comparative adjustable transfemoral amputation interface in subjective and performance outcomes. There is a lack of clinical trials and evidence comparing socket functional outcomes related to volume fluctuation. PMID:28066526
Komatsu, Teruya; Sakaguchi, Yasuto; Muranishi, Yusuke; Yutaka, Yojiro; Date, Hiroshi; Nakamura, Tatsuo
2018-01-01
Background Costal coaptation pins made of poly-L-lactide (PLA) are clinically available for fixing surgically divided ribs. However, the clinical results of such rib fixation have not been completely satisfactory. We aimed to develop a new rib coaptation socket system and explore its clinical applicability. Methods We surgically divided three consecutive ribs of each beagle dog, and rib coaptation sockets were implanted to stabilize each rib. Fifteen 3-dimensional (3D)-printed and 30 PLA fiber knitted sockets were implanted in five and ten dogs, respectively, to stabilize the artificially divided ribs. Mechanical analysis of the sockets and radiographical examination of costal fixation were performed to evaluate the effectiveness of the newly developed socket system for rib stabilization. Results All 15 ribs with 3D-printed sockets had displaced 1 month after the operation. Three ribs in one dog with implanted PLA fiber knitted sockets were displaced radiographically after 1 month, and the grade of displacement remained unchanged after 6 months. The remaining 27 ribs fixed with PLA fiber knitted sockets did not show any displacement. Conclusions The PLA fiber knitted rib coaptation socket system was sufficiently durable for the stabilization of divided ribs with biocompatibility. This promising finding can be applied for clinical stabilization of divided ribs. PMID:29850125
Laing, Sheridan; Lythgo, Noel; Lavranos, Jim; Lee, Peter Vee Sin
2017-10-01
This study compared the physical function and comfort level of patients with unilateral transtibial amputation after being fitted with a hand-cast Patella Tendon Bearing (PTB) socket and a pressure-cast (PCAST) hydrocast socket. The latter technique aims to reduce the skill dependency currently required for socket manufacture and fit. The study was conducted at the Vietnamese Training Centre for Orthopaedic Technologies and involved seventeen Vietnamese participants with unilateral transtibial amputation, all of whom were long term users of prosthetics. All participants were fitted with two sockets manufactured using both hand-cast and PCAST techniques with International Committee of the Red Cross components. Walking tests (timed up and go test and six-minute-walk-test), spatio-temporal gait analyses and subjective comfort assessments were completed after a short acclimatisation period with each socket. The participant-preferred socket was also noted. No significant differences were found for the measures of mobility, functional capacity, spatio-temporal gait parameters, gait symmetry, perceived comfort or participant socket preference. The results show the initial patient outcomes are similar when participants are fitted with a hand-cast PTB socket and a PCAST hydrocast sockets. Future work should confirm these findings in a longer trial. Copyright © 2017 Elsevier B.V. All rights reserved.
Komatsu, Teruya; Sato, Toshihiko; Sakaguchi, Yasuto; Muranishi, Yusuke; Yutaka, Yojiro; Date, Hiroshi; Nakamura, Tatsuo
2018-04-01
Costal coaptation pins made of poly-L-lactide (PLA) are clinically available for fixing surgically divided ribs. However, the clinical results of such rib fixation have not been completely satisfactory. We aimed to develop a new rib coaptation socket system and explore its clinical applicability. We surgically divided three consecutive ribs of each beagle dog, and rib coaptation sockets were implanted to stabilize each rib. Fifteen 3-dimensional (3D)-printed and 30 PLA fiber knitted sockets were implanted in five and ten dogs, respectively, to stabilize the artificially divided ribs. Mechanical analysis of the sockets and radiographical examination of costal fixation were performed to evaluate the effectiveness of the newly developed socket system for rib stabilization. All 15 ribs with 3D-printed sockets had displaced 1 month after the operation. Three ribs in one dog with implanted PLA fiber knitted sockets were displaced radiographically after 1 month, and the grade of displacement remained unchanged after 6 months. The remaining 27 ribs fixed with PLA fiber knitted sockets did not show any displacement. The PLA fiber knitted rib coaptation socket system was sufficiently durable for the stabilization of divided ribs with biocompatibility. This promising finding can be applied for clinical stabilization of divided ribs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shen, Weidian
This project, “Building Surface Science Capacity to Serve the Automobile Industry in Southeastern Michigan” was carried out in two phases: (1) the 2009 – 2012 renovation of space in the new EMU Science Complex, which included the Surface Science Laboratory (SSL), a very vigorous research lab at EMU that carries on a variety of research projects to serve the auto and other industries in Michigan; and (2) the 2013 purchase of several pieces of equipment to further enhance the research capability of the SSL. The funding granted by the DoE was proposed to “renovate the space in the Science Complexmore » to include SSL and purchase equipment for tribological and electrochemical impedance measurements in the lab, thus SSL will serve the auto and other industries in Michigan better.” We believe we have fully accomplished the mission.« less
Adjustable link for kinematic mounting systems
Hale, Layton C.
1997-01-01
An adjustable link for kinematic mounting systems. The adjustable link is a low-cost, passive device that provides backlash-free adjustment along its single constraint direction and flexural freedom in all other directions. The adjustable link comprises two spheres, two sockets in which the spheres are adjustable retain, and a connection link threadly connected at each end to the spheres, to provide a single direction of restraint and to adjust the length or distance between the sockets. Six such adjustable links provide for six degrees of freedom for mounting an instrument on a support. The adjustable link has applications in any machine or instrument requiring precision adjustment in six degrees of freedom, isolation from deformations of the supporting platform, and/or additional structural damping. The damping is accomplished by using a hollow connection link that contains an inner rod and a viscoelastic separation layer between the two.
Adjustable link for kinematic mounting systems
Hale, L.C.
1997-07-01
An adjustable link for kinematic mounting systems is disclosed. The adjustable link is a low-cost, passive device that provides backlash-free adjustment along its single constraint direction and flexural freedom in all other directions. The adjustable link comprises two spheres, two sockets in which the spheres are adjustable retain, and a connection link threadly connected at each end to the spheres, to provide a single direction of restraint and to adjust the length or distance between the sockets. Six such adjustable links provide for six degrees of freedom for mounting an instrument on a support. The adjustable link has applications in any machine or instrument requiring precision adjustment in six degrees of freedom, isolation from deformations of the supporting platform, and/or additional structural damping. The damping is accomplished by using a hollow connection link that contains an inner rod and a viscoelastic separation layer between the two. 3 figs.
Flügge, Tabea; Nelson, Katja; Nack, Claudia; Stricker, Andres; Nahles, Susanne
2015-04-01
This study identified the soft tissue changes of the alveolar ridge at different time points within 12 weeks after tooth extraction with and without socket augmentation. In 38 patients with single tooth extractions, 40 sockets were augmented and 39 extraction sockets were not augmented. At 2, 4, 6, 8 and 12 weeks impressions were taken and casts digitized with a laser scanner. The horizontal and vertical changes were compared between augmented and non-augmented sites. A p-value <0.05 was considered statistically significant. The mean changes of augmented sockets were between 0.4 mm (2 weeks) and 0.8 mm (12 weeks). In non-augmented sockets changes of 0.7 mm (2 weeks) and of 1.0 mm (12 weeks) were demonstrated. The mean values differed significantly between the buccal and oral region (p < 0.01). Overall, there were significant differences of the mean dimensional changes regarding time (p < 0.01) and augmentation (p < 0.01). Augmented sockets showed less resorption within 4 weeks after extraction compared to non-augmented sockets. Non-augmented sockets showed a continuous dimensional loss with a great variation over 12 weeks whereas augmented sockets had the highest degree of resorption between 4 and 6 weeks. At 12 weeks a comparable resorption in augmented and non-augmented sockets was observed. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Continuity tester screens out faulty socket connections
NASA Technical Reports Server (NTRS)
Golding, G.
1964-01-01
A device, used before and after assembly, tests the continuity of an electrical circuit through each pin and socket of multiple connector sockets. Electrically insulated except at the contact area, a test probe is dimensioned to make contact only in properly formed sockets.
Sarode, Ashish; Wang, Peng; Cote, Catherine; Worthen, David R
2013-03-01
Hydroxypropylcellulose (HPC)-SL and -SSL, low-viscosity hydroxypropylcellulose polymers, are versatile pharmaceutical excipients. The utility of HPC polymers was assessed for both dissolution enhancement and sustained release of pharmaceutical drugs using various processing techniques. The BCS class II drugs carbamazepine (CBZ), hydrochlorthiazide, and phenytoin (PHT) were hot melt mixed (HMM) with various polymers. PHT formulations produced by solvent evaporation (SE) and ball milling (BM) were prepared using HPC-SSL. HMM formulations of BCS class I chlorpheniramine maleate (CPM) were prepared using HPC-SL and -SSL. These solid dispersions (SDs) manufactured using different processes were evaluated for amorphous transformation and dissolution characteristics. Drug degradation because of HMM processing was also assessed. Amorphous conversion using HMM could be achieved only for relatively low-melting CBZ and CPM. SE and BM did not produce amorphous SDs of PHT using HPC-SSL. Chemical stability of all the drugs was maintained using HPC during the HMM process. Dissolution enhancement was observed in HPC-based HMMs and compared well to other polymers. The dissolution enhancement of PHT was in the order of SE>BM>HMM>physical mixtures, as compared to the pure drug, perhaps due to more intimate mixing that occurred during SE and BM than in HMM. Dissolution of CPM could be significantly sustained in simulated gastric and intestinal fluids using HPC polymers. These studies revealed that low-viscosity HPC-SL and -SSL can be employed to produce chemically stable SDs of poorly as well as highly water-soluble drugs using various pharmaceutical processes in order to control drug dissolution.
Darter, Benjamin J; Sinitski, Kirill; Wilken, Jason M
2016-10-01
Elevated vacuum suspension systems use a pump to draw air from the socket with the intent of reducing bone-socket motion as compared to passive suction systems. However, it remains unknown if elevated vacuum suspension systems decrease limb displacement uniformly during transitions from unloaded to full-body-weight support. To compare limb-socket motion between elevated vacuum and passive suction suspension sockets using a controlled loading paradigm. Comparative analysis. Persons with transtibial amputation were assessed while wearing either an elevated vacuum or passive suction suspension socket. Digital video fluoroscopy was used to measure axial bone-socket motion while the limb was loaded in 20% body-weight increments. An analysis of variance model was used to compare between suspension types. Total axial displacement (0%-100% body weight) was significantly lower using the elevated vacuum (vacuum: 1.3 cm, passive suction: 1.8 cm; p < 0.0001). Total displacement decreased primarily due to decreased motion during initial loading (0%-20%; p < 0.0001). Other body-weight intervals were not significantly different between systems. Elevated vacuum suspension reduced axial limb-socket motion by maintaining position of the limb within the socket during unloaded conditions. Elevated vacuum provided no meaningful improvement in limb-socket motion past initial loading. Excessive bone-socket motion contributes to poor residual limb health. Our results suggest elevated vacuum suspensions can reduce this axial displacement. Visual assessment of the images suggests that this occurs through the reduction or elimination of the air pocket between the liner and socket wall while the limb is unloaded. © The International Society for Prosthetics and Orthotics 2015.
2010-09-01
The popular recognition of the Aloe barbadensis Miller (Aloe vera) plant as a therapeutic dermatologic agent has led to the widespread incorporation of Aloe vera leaf extracts in skincare products. Studies have suggested that Aloe vera in skincare preparations may enhance the induction of skin cancer by ultraviolet radiation. A 1-year study was conducted in mice to determine whether the topical application of creams containing Aloe vera plant extracts (aloe gel, whole leaf, or decolorized whole leaf) or creams containing aloe-emodin would enhance the photocarcinogenicity of simulated solar light (SSL). 1-YEAR STUDY: groups of 36 male and 36 female Crl:SKH-1 (hr -/hr -) hairless mice received topical applications of control cream or creams containing 3% or 6% (w/w) aloe gel, whole leaf, or decolorized whole leaf or 7.46 or 74.6 µg/g aloe-emodin to the dorsal skin region each weekday morning. The mice were irradiated with SSL emitted from filtered 6 kW xenon arc lamps each weekday afternoon. The topical applications of creams and irradiance exposures were conducted 5 days per week for a period of 40 weeks. A 12-week recovery/observation period followed the 40-week treatment/exposure period. Additional groups of 36 male and 36 female mice received no cream and were exposed to 0.00, 6.85, 13.70, or 20.55 mJ⋅CIE/cm2 SSL per day. Mice that received no cream treatment and were exposed to increasing levels of SSL showed significant SSL exposure-dependent decreases in survival and significant increases in the in-life observations of skin lesion onset, incidence, and multiplicity, and significant SSL exposure-dependent increases in the incidences and multiplicities of histopathology-determined squamous cell nonneoplastic skin lesions (squamous hyperplasia and focal atypical hyperplasia) and squamous cell neoplasms (papilloma, carcinoma in situ, and/or carcinoma). Squamous cell neoplasms were not detected in mice that received no SSL exposure. The topical treatment with the control cream of mice that were exposed to SSL did not impart a measurable effect when compared with comparable measurements in mice that received no cream treatment and were exposed to the same level of SSL, suggesting that the control cream used in these studies did not alter the efficiency of the SSL delivered to mice or the tolerability of mice to SSL. The application of aloe gel creams to mice had no effect on body weights, survival, or the in-life observations of skin lesion onset, incidence, or multiplicity. The administration of aloe gel creams to male mice had no effect on the incidences or multiplicities of histopathology-determined squamous cell nonneoplastic skin lesions or neoplasms. Female mice treated with aloe gel creams (3% and 6%) had significantly increased multiplicities of squamous cell neoplasms. There were no treatment-related effects on body weights, survival, or the in-life observations of skin lesion onset, incidence, or multiplicity in mice treated with the whole leaf creams. In male mice exposed to SSL and treated with the 6% whole leaf cream, a significant increase was observed in the multiplicity of squamous cell neoplasms. Female mice exposed to SSL and treated with the 3% whole leaf creams had significantly decreased multiplicity of squamous cell nonneoplastic lesions and significantly increased multiplicity of squamous cell neoplasms. Female mice exposed to SSL and treated with the 6% whole leaf cream had significantly decreased multiplicity of squamous cell nonneoplastic lesions. The application of decolorized whole leaf creams to mice had no effect on body weights, survival, or the in-life observations of skin lesion onset, incidence, or multiplicity. Male mice administered the 3% decolorized whole leaf cream had significantly increased multiplicity of squamous cell neoplasms. Female mice administered the 3% decolorized whole leaf cream had significantly decreased multiplicity of squamous cell nonneoplastic skin lesions and significantly increased multiplicity of squamous cell neoplasms. In female mice that received the 6% decolorized whole leaf cream, there was a significant increase in the multiplicity of squamous cell neoplasms. As with the Aloe vera plant extracts, the application of aloe-emodin creams to mice had no measurable effect on body weights, survival, or the in-life observations of skin lesion onset, incidence, or multiplicity. The administration of aloe-emodin creams to male mice had no effect on the incidence or multiplicity of histopathology-determined nonneoplastic skin lesions or squamous cell neoplasms. Female mice treated with the 74.6 µg/g aloe-emodin cream had significantly decreased multiplicity of histopathology-determined squamous cell nonneoplastic skin lesions and significantly increased multiplicity of squamous cell neoplasms. these experiments investigated the potential of topical application of creams containing extracts of Aloe barbadensis Miller plant (aloe gel, whole leaf, or decolorized whole leaf) or aloe-emodin to alter the photocarcinogenic activity of filtered xenon arc simulated solar light (SSL) in male and female SKH-1 hairless mice. Data on skin lesions were collected both on digital images during the in-life phase and by histopathologic evaluation at necropsy. No effects of creams upon SSL-induced skin lesions were identified from data collected during the in-life phase. ALOE GEL OR ALOE-EMODIN: under the conditions of these studies, there was a weak enhancing effect of aloe gel or aloe-emodin on the photocarcinogenic activity of SSL in female but not in male SKH-1 mice based on an increase in the multiplicity of histopathologically-determined squamous cell neoplasms. under the conditions of these studies, there was a weak enhancing effect of aloe whole leaf or decolorized whole leaf on the photocarcinogenic activity of SSL in both male and female SKH-1 mice based on an increase in the multiplicity of histopathologically-determined squamous cell neoplasms.
A retrospective study on the use of a dental dressing to reduce dry socket incidence in smokers.
Murph, James T; Jaques, Susan H; Knoell, Alexander N; Archibald, Geoffrey D; Yang, Stan
2015-01-01
This study assessed the effectiveness of using an oxidized cellulose dental dressing in order to reduce the rate of alveolar osteitis after posterior tooth extraction in smokers. Dry socket incidences of heavy smokers from 4 independent dental clinics, which routinely used oxidized cellulose dental dressings to mitigate dry socket formation between March 2011 and December 2012, were compiled and evaluated. All extraction sites healed uneventfully except for those cases that developed dry sockets. Overall, 1.7% of male patients and 2.2% of female patients developed dry sockets. No conclusive relationship was found between the number of cigarettes smoked and dry socket formation among patients in this study. The results of this study were consistent with the view that gender, age, postextraction regimen, and multiple extractions affect dry socket formation. The results indicate that an oxidized cellulose dental dressing postextraction is a safe and effective method for mitigating dry socket formation among smokers.
Dry socket: incidence, clinical features, and predisposing factors.
Akinbami, Babatunde O; Godspower, Thikan
2014-01-01
Background. Dry socket is a global phenomenon. The purpose of the study was to investigate the incidence of dry socket in recent times in a Nigerian Tertiary Hospital. Methods. Patients who were referred for dental extractions were included in the study. The case files of patients were obtained and information retrieved included biodata, indication for extraction, number and type of teeth extracted, oral hygiene status, compliance to oral hygiene instructions, and development of dry socket. Results. One thousand, one hundred and eighty two patients with total of 1362 teeth extracted during the 4-year period of the study were analyzed, out of which 1.4% teeth developed dry socket. The mean age (SD) was 35.2 (16.0) years. Most of the patients who presented with dry socket were in the fourth decade of life. Mandibular teeth were affected more than maxillary teeth. Molars were more affected. Retained roots and third molars were conspicuous in the cases with dry socket. Conclusion. The incidence of dry socket in our centre was lower than previous reports. Oral hygiene status, lower teeth, and female gender were significantly associated with development of dry socket. Treatment with normal saline irrigation and ZnO eugenol dressings allowed relief of the symptoms.
Dry Socket: Incidence, Clinical Features, and Predisposing Factors
Akinbami, Babatunde O.; Godspower, Thikan
2014-01-01
Background. Dry socket is a global phenomenon. The purpose of the study was to investigate the incidence of dry socket in recent times in a Nigerian Tertiary Hospital. Methods. Patients who were referred for dental extractions were included in the study. The case files of patients were obtained and information retrieved included biodata, indication for extraction, number and type of teeth extracted, oral hygiene status, compliance to oral hygiene instructions, and development of dry socket. Results. One thousand, one hundred and eighty two patients with total of 1362 teeth extracted during the 4-year period of the study were analyzed, out of which 1.4% teeth developed dry socket. The mean age (SD) was 35.2 (16.0) years. Most of the patients who presented with dry socket were in the fourth decade of life. Mandibular teeth were affected more than maxillary teeth. Molars were more affected. Retained roots and third molars were conspicuous in the cases with dry socket. Conclusion. The incidence of dry socket in our centre was lower than previous reports. Oral hygiene status, lower teeth, and female gender were significantly associated with development of dry socket. Treatment with normal saline irrigation and ZnO eugenol dressings allowed relief of the symptoms. PMID:24987419
Mitton, Kay; Kulkarni, Jai; Dunn, Kenneth William; Ung, Anthony Hoang
2017-10-01
This novel case report describes the problems of prescribing a prosthetic socket in a left transfemoral amputee secondary to chronic patellofemoral instability compounded by complex regional pain syndrome. Case Description and Methods: Following the amputation, complex regional pain syndrome symptoms recurred in the residual limb, presenting mainly with oedema. Due to extreme daily volume fluctuations of the residual limb, a conventional, laminated thermoplastic socket fitting was not feasible. Findings and Outcomes: An adjustable, modular socket design was trialled. The residual limb volume fluctuations were accommodated within the socket. Amputee rehabilitation could be continued, and the rehabilitation goals were achieved. The patient was able to wear the prosthesis for 8 h daily and to walk unaided indoors and outdoors. An adjustable, modular socket design accommodated the daily residual limb volume fluctuations and provided a successful outcome in this case. It demonstrates the complexities of socket fitting and design with volume fluctuations. Clinical relevance Ongoing complex regional pain syndrome symptoms within the residual limb can lead to fitting difficulties in a conventional, laminated thermoplastic socket due to volume fluctuations. An adjustable, modular socket design can accommodate this and provide a successful outcome.
Wang, Yao-zhong; Guan, Qun-li; Li, Ya-xin; Guo, Ji-lai; Jiang, Ling; Jia, Mu-yun; Deng, Yue
2013-02-01
To study the clinical effect of "gelatamp" colloidal silver gelatin sponge on preventing dry socket after extracting the mandibular impacted teeth. 1350 teeth extracted from 976 patients who needed to extract the mandibular impacted teeth were divided into group A, group B and group C randomly. "Gelatamp" colloidal silver gelatin sponge was implanted into alveolar socket after teeth extraction in group A, with absorbable gelatin sponge was implanted into alveolar socket in group B and nothing was implanted into alveolar socket in group C. The incidence of dry socket was observed, the data was analyzed using SPSS10.0 software package. The incidence of dry socket was 0.44% in group A, 2% in group B and 4.44% in group C. There was significant difference in the incidence of dry socket between group A and group C(P<0.01). There was also significant difference between group B and group C(P<0.05) and between group A and group B(P<0.05). The results demonstrate that "gelatamp" colloidal silver gelatin sponge can prevent the occurrence of dry socket after teeth extraction, which is of wide clinical use.
Interventions for the prevention of dry socket: an evidence-based update.
Sharif, M O; Dawoud, B E S; Tsichlaki, A; Yates, J M
2014-07-11
This paper reviews the latest evidence for local and systemic interventions for the prevention of alveolar osteitis (dry socket). Dry socket is a painful and common post-operative complication following exodontia. Any interventions for the prevention of dry socket could reduce both its incidence and help avoid this painful complication. Prophylactic measures proposed in the literature are discussed. Furthermore, this article discusses both the clinical and histological stages of a normal healing socket.
Coronal plane socket stability during gait in persons with transfemoral amputation: Pilot study.
Fatone, Stefania; Dillon, Michael; Stine, Rebecca; Tillges, Robert
2014-01-01
Little research describes which transfemoral socket design features are important for coronal plane stability, socket comfort, and gait. Our study objectives were to (1) relate socket comfort during gait to a rank order of changes in ischial containment (IC) and tissue loading and (2) compare socket comfort during gait when tissue loading and IC were systematically manipulated. Six randomly assigned socket conditions (IC and tissue compression) were assessed: (1) IC and high, (2) IC and medium, (3) IC and low, (4) no IC and high, (5) no IC and medium, and (6) no IC and low. For the six subjects in this study, there was a strong, negative relationship between comfort and changes in IC and tissue loading (rho = -0.89). With the ischium contained, tissue loading did not influence socket comfort (p = 0.47). With no IC, the socket was equally comfortable with high tissue loading (p = 0.36) but the medium (p = 0.04) and low (p = 0.02) tissue loading conditions decreased comfort significantly. Coronal plane hip moments, lateral trunk lean, step width, and walking speed were invariant to changes in IC and/or tissue loading. Our results suggest that in an IC socket, medial tissue loading mattered little in terms of comfort. Sockets without IC required high tissue loading to be as comfortable as those with IC, while suboptimal tissue loading compromised comfort.
Single-Rooted Extraction Sockets: Classification and Treatment Protocol.
El Chaar, Edgar; Oshman, Sarah; Fallah Abed, Pooria
2016-09-01
Clinicians have many treatment techniques from which to choose when extracting a failing tooth and replacing it with an implant-supported restoration and when successful management of an extraction socket during the course of tooth replacement is necessary to achieve predictable and esthetic outcomes. This article presents a straightforward, yet thorough, classification for extraction sockets of single-rooted teeth and provides guidance to clinicians in the selection of appropriate and predictable treatment. The presented classification of extraction sockets for single-rooted teeth focuses on the topography of the extraction socket, while the protocol for treatment of each socket type factors in the shape of the remaining bone, the biotype, and the location of the socket whether it be in the mandible or maxilla. This system is based on the biologic foundations of wound healing and can help guide clinicians to successful treatment outcomes.
Modular socket system versus traditionally laminated socket: a cost analysis.
Normann, Elna; Olsson, Anna; Brodtkorb, Thor-Henrik
2011-03-01
Using the new modular socket system (MSS) to produce a prosthetic socket directly on the patient has the potential of being easier and quicker to manufacture but also incurring higher costs. The purpose of the study was to compare the costs of manufacturing a transtibial prosthetic socket using either a MSS or a standard laminated socket (PC). Concurrent controlled trial. A total of 20 patients at two orthopaedic facilities were followed with regards to the cost of manufacturing a prosthetic socket using either MSS or PC. Time aspects and material costs were considered in the cost analysis. Other factors studied include delivery time and number of visits. For the cost analysis, only direct costs pertaining to the prosthetic socket were considered. The total cost of MSS was found to be significantly higher (p < 0.01) compared to PC. However, the production and time cost was significantly lower. Delivery time to the patient was 1 day for MSS compared to 17 days for PC. Our study shows that the direct prosthetic cost of treating a patient using MSS is significantly higher than treating a patient using PC. However, the MSS prosthesis can be delivered significantly faster and with fewer visits. Further studies taking the full societal costs of MSS into account should therefore be performed. This study shows that the direct prosthetic cost of treating a patient with Modular Socket System is significantly higher than treating a patient with plastercasting with standard laminated socket. However, the Modular Socket System prosthesis can be delivered significantly faster and with fewer visits.
An Amino Acid Code for Irregular and Mixed Protein Packing
Joo, Hyun; Chavan, Archana; Fraga, Keith; Tsai, Jerry
2015-01-01
To advance our understanding of protein tertiary structure, the development of the knob-socket model is completed in an analysis of the packing in irregular coil and turn secondary structure packing as well as between mixed secondary structure. The knob-socket model simplifies packing based on repeated patterns of 2 motifs: a 3 residue socket for packing within 2° structure and a 4 residue knob-socket for 3° packing. For coil and turn secondary structure, knob-sockets allow identification of a correlation between amino acid composition and tertiary arrangements in space. Coil contributes almost as much as α-helices to tertiary packing. Irregular secondary structure involves 3 residue cliques of consecutive contacting residues or XYZ sockets. In irregular sockets, Gly, Pro, Asp and Ser are favored, while Cys, His, Met and Trp are not. For irregular knobs, the preference order is Arg, Asp, Pro, Asn, Thr, Leu, and Gly, while Cys, His, Met and Trp are not. In mixed packing, the knob amino acid preferences are a function of the socket that they are packing into, whereas the amino acid composition of the sockets does not depend on the secondary structure of the knob. A unique motif of a coil knob with an XYZ β-sheet socket may potentially function to inhibit β-sheet extension. In addition, analysis of the preferred crossing angles for strands within a β-sheet and mixed α-helices/β-sheets identifies canonical packing patterns useful in protein design. Lastly, the knob-socket model abstracts the complexity of protein tertiary structure into an intuitive packing surface topology map. PMID:26370334
Sodium hyaluronate accelerates the healing process in tooth sockets of rats.
Mendes, Renato M; Silva, Gerluza A B; Lima, Miguel F; Calliari, Marcelo V; Almeida, Alvair P; Alves, José B; Ferreira, Anderson J
2008-12-01
In this study we evaluated the effects of sodium hyaluronate (HY) in the healing process of tooth sockets of rats. Immediately after the extraction of the upper first molars of male Holtzman rats, right sockets were treated with 1% HY gel (approximately 0.1 ml), while left sockets were used as control (blood clot). The animals were sacrificed at 2, 7, and 21 days after tooth extraction and upper maxillaries processed for histological and morphometric analysis of the apical and medium thirds of the sockets. Carbopol, an inert gel, was used to evaluate the mechanical effect of gel injection into sockets. Expression of bone morphogenetic protein-2 (BMP-2) and osteopontin (OPN) was determined by immunohistochemistry at 1, 2, 3, 4, 5, and 7 days after tooth extraction. Histological analysis showed that HY treatment induced earlier trabecular bone deposition resulting in a bone matrix more organized at 7 and 21 days after tooth extraction. Also, HY elicited significant increase in the amount of bone trabeculaes at 7 and 21 days after tooth extraction (percentage of trabecular bone area at 7 days: 13.21+/-4.66% vs. 2.58+/-1.36% in the apical third of control sockets) and in the vessels counting at 7 days. Conversely, the number of cell nuclei was decreased in HY-treated sockets. Additionally, expression of BMP-2 and OPN was enhanced in HY-treated sockets compared with control sockets. These findings suggest that HY accelerates the healing process in tooth sockets of rats stimulating the expression of osteogenic proteins.
Dry Socket: Frequency, Clinical Picture, and Risk Factors in a Palestinian Dental Teaching Center
Abu Younis, Mohammed H; Abu Hantash, Ra'ed O
2011-01-01
Aims: The objectives of this study were to find out the frequency, clinical picture, and risk factors of dry socket at the Dental Teaching Center of Al-Quds University in Palestine. Methods and Materials: Two previously used questionnaires were accomplished in this study over a one year period. The first questionnaire was completed for every patient who had one or more permanent teeth extracted in the Dental Surgery Clinic. The other one was completed for every patient suffered a postoperative pain and was diagnosed with dry socket. Results: There were 1305 dental extractions performed in 805 patients. The overall frequency of dry socket was 3.2%. The incidence of dry socket following non-surgical extractions was 1.7% while it was 15% following surgical extractions (P< 0.005). The incidence of dry socket was significantly higher in smokers (12%) than in non-smokers (4%) (P < 0.005), however, there is a strong association between the amount of smoking and the incidence of dry socket (P < 0.002). The incidence of dry socket was significantly higher in the single extraction cases (13%) than in the multiple extraction cases (5%) (P = 0.005). Age, sex, medical history, extraction site, amount of local anesthesia and experience of operator play no role in the occurrence of dry socket. Conclusion: Smoking, surgical trauma and single extractions are considered predisposing factors in the occurrence of dry socket. On the other hand, factors like: age, sex, medical history, extraction site, amount of anesthesia, and operator experience have no effect on the observation of dry socket. PMID:21559187
Final Report: System Reliability Model for Solid-State Lighting (SSL) Luminaires
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davis, J. Lynn
2017-05-31
The primary objectives of this project was to develop and validate reliability models and accelerated stress testing (AST) methodologies for predicting the lifetime of integrated SSL luminaires. This study examined the likely failure modes for SSL luminaires including abrupt failure, excessive lumen depreciation, unacceptable color shifts, and increased power consumption. Data on the relative distribution of these failure modes were acquired through extensive accelerated stress tests and combined with industry data and other source of information on LED lighting. This data was compiled and utilized to build models of the aging behavior of key luminaire optical and electrical components.
Why the developing world is the perfect market place for solid state lighting
NASA Astrophysics Data System (ADS)
Schultz, Christoph; Platonova, Inna; Doluweera, Ganesh; Irvine-Halliday, Dave
2008-08-01
Much has been written about the daily challenge for survival faced by countless millions of developing world families and the overdeveloped world has offered a number of solutions by which those at the base of the economic pyramid (BOP) can help themselves. Light Up The World (LUTW), the global leader in bringing Renewable Energy (RE) based Solid State Lighting (SSL) to the developing world, offers yet another solution, and one that comes with a very high probability of success. In this paper we discuss: the critical role played by micro credit (banking for the poor); a typical example of a developing world community and their lighting needs and expenditures; how SSL can contribute positively to all eight of the Millennium Development Goals; the micro and macroeconomics of SSL at the BOP, its numerous societal benefits and its potential perverse outcomes; and thought there will always be a role for the donation based model, it is only through the market model that safe, healthy and affordable SSL will reach the majority of the BOP, such are the staggering numbers involved. LUTW's fundamental goal, through the facilitation of RE based SSL, is to improve the quality of life of those, who through no fault of their own, find themselves trapped in a cycle of poverty.
Wines, Bruce D; Ramsland, Paul A; Trist, Halina M; Gardam, Sandra; Brink, Robert; Fraser, John D; Hogarth, P Mark
2011-09-23
Host survival depends on an effective immune system and pathogen survival on the effectiveness of immune evasion mechanisms. Staphylococcus aureus utilizes a number of molecules to modulate host immunity, including the SSL family of which SSL7 binds IgA and inhibits Fcα receptor I (FcαRI)-mediated function. Other Gram-positive bacterial pathogens produce IgA binding proteins, which, similar to SSL7, also bind the Fc at the CH2/CH3 interface (the junction between constant domains 2 and 3 of the heavy chain). The opposing activities of the host FcαRI-IgA receptor ligand pair and the pathogen decoy proteins select for host and pathogen variants, which exert stronger protection or evasion, respectively. Curiously, mouse but not rat IgA contains a putative N-linked glycosylation site in the center of this host receptor and pathogen-binding site. Here, we demonstrate that this site is glycosylated and that the effect of amino acid changes and glycosylation of the CH2/CH3 interface inhibits interaction with the pathogen IgA binding protein SSL7, while maintaining binding of pIgR, essential to the biosynthesis and transport of SIgA.
30 CFR 57.12035 - Weatherproof lamp sockets.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Weatherproof lamp sockets. 57.12035 Section 57.12035 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12035 Weatherproof lamp sockets. Lamp sockets shall be of a weatherproof type...
30 CFR 57.12035 - Weatherproof lamp sockets.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Weatherproof lamp sockets. 57.12035 Section 57.12035 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12035 Weatherproof lamp sockets. Lamp sockets shall be of a weatherproof type...
30 CFR 57.12035 - Weatherproof lamp sockets.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Weatherproof lamp sockets. 57.12035 Section 57.12035 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12035 Weatherproof lamp sockets. Lamp sockets shall be of a weatherproof type...
30 CFR 57.12035 - Weatherproof lamp sockets.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Weatherproof lamp sockets. 57.12035 Section 57.12035 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12035 Weatherproof lamp sockets. Lamp sockets shall be of a weatherproof type...
30 CFR 57.12035 - Weatherproof lamp sockets.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Weatherproof lamp sockets. 57.12035 Section 57.12035 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12035 Weatherproof lamp sockets. Lamp sockets shall be of a weatherproof type...
46 CFR 56.30-30 - Brazed joints.
Code of Federal Regulations, 2010 CFR
2010-10-01
....75). Brazed socket-type joints shall be made with suitable brazing alloys. The minimum socket depth shall be sufficient for the intended service. Brazing alloy shall either be end-fed into the socket or shall be provided in the form of a preinserted ring in a groove in the socket. The brazing alloy shall...
46 CFR 56.30-30 - Brazed joints.
Code of Federal Regulations, 2013 CFR
2013-10-01
....75). Brazed socket-type joints shall be made with suitable brazing alloys. The minimum socket depth shall be sufficient for the intended service. Brazing alloy shall either be end-fed into the socket or shall be provided in the form of a preinserted ring in a groove in the socket. The brazing alloy shall...
46 CFR 56.30-30 - Brazed joints.
Code of Federal Regulations, 2011 CFR
2011-10-01
....75). Brazed socket-type joints shall be made with suitable brazing alloys. The minimum socket depth shall be sufficient for the intended service. Brazing alloy shall either be end-fed into the socket or shall be provided in the form of a preinserted ring in a groove in the socket. The brazing alloy shall...
46 CFR 56.30-30 - Brazed joints.
Code of Federal Regulations, 2014 CFR
2014-10-01
....75). Brazed socket-type joints shall be made with suitable brazing alloys. The minimum socket depth shall be sufficient for the intended service. Brazing alloy shall either be end-fed into the socket or shall be provided in the form of a preinserted ring in a groove in the socket. The brazing alloy shall...
46 CFR 56.30-30 - Brazed joints.
Code of Federal Regulations, 2012 CFR
2012-10-01
....75). Brazed socket-type joints shall be made with suitable brazing alloys. The minimum socket depth shall be sufficient for the intended service. Brazing alloy shall either be end-fed into the socket or shall be provided in the form of a preinserted ring in a groove in the socket. The brazing alloy shall...
Dutta, Shubha Ranjan; Singh, Purnima; Passi, Deepak; Patter, Pradeep
2015-09-01
To evaluate the efficacy of autologous platelet rich plasma (PRP) in regeneration of bone and to assess clinical compatibility of the material in mandibular third molar extraction socket. To compare the healing of mandibular third molar extraction wounds with and without PRP. Group A consists of the 30 patients where PRP will be placed in the extraction socket before closure of the socket. Group B consists of 30 patients who will be the control group where the extraction sockets will be closed without any intra socket medicaments. The patients would be allocated to the groups randomly. Soft tissue healing was better in study site compared to control site. The result of the study shows rapid bone regeneration in the extraction socket treated with PRP when compared with the socket without PRP. Evaluation for bone blending and trabecular bone formation started earlier in PRP site compared to control, non PRP site. Also there was less postoperative discomfort on the PRP treated side. Autologous PRP is biocompatible and has significant improved soft tissue healing, bone regeneration and increase in bone density in extraction sockets.
Clinical outcome and complications of thoracic and pelvic limb stump and socket prostheses.
Phillips, Andrew; Kulendra, Elvin; Bishop, Edith; Monk, Michelle; Parsons, Kevin; House, Arthur
2017-07-20
To describe the use, quality of life, compliance, complications, and outcome of animals fitted with stump socket prostheses. Medical records of dogs fitted with a stump socket prosthesis were reviewed. Functional outcome, quality of life and complications were retrospectively assessed from an owner questionnaire. Thirteen stump socket prostheses (12 dogs) were fitted for a variety of reasons including trauma, congenital abnormalities, and neoplasia. Eight dogs had a good outcome overall and four a poor outcome. Quality of life (QOL) remained good or excellent in 10/12 dogs. Nine complications were seen in 7/12 dogs, most were manageable; surgical wound complications (n = 2) and pressures sores (n = 4) were the most frequently encountered. One dog suffered multiple complications. Thoracic and pelvic limb stump socket prostheses had a similar complication rate, however all animals with a poor outcome had a thoracic limb stump socket prosthesis; two were small breed dogs (under 10 kg) and two had bilateral thoracic limb abnormalities. Stump socket prostheses are feasible and versatile in animals. In correctly selected cases, good to excellent outcomes are possible. However, complications are frequent but often manageable. Further investigations are required into the risk factors for poor outcomes and prospective studies are required to assess changes in biomechanics, function, and QOL before and after fitting of a stump socket prosthesis. Until further evidence is available, careful consideration should be given before fitting bilateral thoracic limb stump socket prostheses or thoracic limb stump socket prostheses to small breed dogs.
Boone, David A; Kobayashi, Toshiki; Chou, Teri G; Arabian, Adam K; Coleman, Kim L; Orendurff, Michael S; Zhang, Ming
2013-04-01
Alignment - the process and measured orientation of the prosthetic socket relative to the foot - is important for proper function of a transtibial prosthesis. Prosthetic alignment is performed by prosthetists using visual gait observation and amputees' feedback. The aim of this study was to investigate the effect of transtibial prosthesis malalignment on the moments measured at the base of the socket: the socket reaction moments. Eleven subjects with transtibial amputation were recruited from the community. An instrumented prosthesis alignment component was used to measure socket reaction moments during ambulation under 17 alignment conditions, including nominally aligned using conventional clinical methods, and angle perturbations of 3° and 6° (flexion, extension, abduction, and adduction) and translation perturbations of 5mm and 10mm (anterior, posterior, lateral, and medial) referenced from the nominal alignment. Coronal alignment perturbations caused systematic changes in the coronal socket reaction moments. All angle and translation perturbations revealed statistically significant differences on coronal socket reaction moments compared to the nominal alignment at 30% and 75% of stance phase (P<0.05). The effect of sagittal alignment perturbations on sagittal socket reaction moments was not as responsive as that of the coronal perturbations. The sagittal angle and translation perturbations of the socket led to statistically significant changes in minimum moment, maximum moment, and moments at 45% of stance phase in the sagittal plane. Therefore, malalignment affected the socket reaction moments in amputees with transtibial prostheses. Copyright © 2012 Elsevier B.V. All rights reserved.
An Amino Acid Packing Code for α-helical Structure and Protein Design
Joo, Hyun; Chavan, Archana G.; Phan, Jamie; Day, Ryan; Tsai, Jerry
2012-01-01
This work demonstrates that all packing in α-helices can be simplified to repetitive patterns of a single motif: the knob-socket. Using the precision of Voronoi Polyhedra/Deluaney Tessellations to identify contacts, the knob-socket is a 4 residue tetrahedral motif: a knob residue on one α-helix packs into the 3 residue socket on another α-helix. The principle of the knob-socket model relates the packing between levels of protein structure: the intra-helical packing arrangements within secondary structure that permit inter-helix tertiary packing interactions. Within an α-helix, the 3 residue sockets arrange residues into a uniform packing lattice. Inter-helix packing results from a definable pattern of interdigitated knob-socket motifs between 2 α-helices. Furthermore, the knob-socket model classifies 3 types of sockets: 1) free: favoring only intra-helical packing, 2) filled: favoring inter-helical interactions and 3) non: disfavoring α-helical structure. The amino acid propensities in these 3 socket classes essentially represent an amino acid code for structure in α-helical packing. Using this code, a novel yet straightforward approach for the design of α-helical structure was used to validate the knob-socket model. Unique sequences for 3 peptides were created to produce a predicted amount of α-helical structure: mostly helical, some helical, and no-helix. These 3 peptides were synthesized and helical content assessed using CD spectroscopy. The measured α-helicity of each peptide was consistent with the expected predictions. These results and analysis demonstrate that the knob-socket motif functions as the basic unit of packing and presents an intuitive tool to decipher the rules governing packing in protein structure. PMID:22426125
Das, Swati; Jhingran, Rajesh; Bains, Vivek Kumar; Madan, Rohit; Srivastava, Ruchi; Rizvi, Iram
2016-01-01
Objectives: This study was primarily designed to determine the clinico-radiographic efficacy of platelet-rich fibrin (PRF) and beta-tri-calcium phosphate with collagen (β-TCP-Cl) in preserving extraction sockets. Materials and Methods: For Group I (PRF), residual sockets (n = 15) were filled with autologous PRF obtained from patients' blood; and for Group II (β-TCP-Cl), residual sockets (n = 15) were filled with β-TCP-Cl. For the sockets randomly selected for Group II (β-TCP-Cl), the reshaped Resorbable Tissue Replacement cone was inserted into the socket. Results: Clinically, there was a significantly greater decrease in relative socket depth, but apposition in midcrestal height in Group II (β-TCP-Cl) as compared to Group I (PRF), whereas more decrease in buccolingual width of Group I (PRF) than Group II (β-TCP-Cl) after 6 months. Radiographically, the mean difference in socket height, residual ridge, and width (coronal, middle, and apical third of socket) after 6 months was higher in Group I (PRF) as compared to Group II (β-TCP-Cl). The mean density (in Hounsfield Units) at coronal, middle, and apical third of socket was higher in Group I (PRF) as compared to Group II (β-TCP-Cl). There were statistically significant apposition and resorption for Group I (PRF) whereas nonsignificant resorption and significant apposition for Group II (β-TCP-Cl) in buccal and lingual/palatal cortical plate, respectively, at 6 months on computerized tomography scan. Conclusion: The use of either autologous PRF or β-TCP-Cl was effective in socket preservation. Results obtained from PRF were almost similar to β-TCP-Cl; therefore being autologous, nonimmune, cost-effective, easily procurable regenerative biomaterial, PRF proves to be an insight into the future biofuel for regeneration. PMID:27095909
Das, Swati; Jhingran, Rajesh; Bains, Vivek Kumar; Madan, Rohit; Srivastava, Ruchi; Rizvi, Iram
2016-01-01
This study was primarily designed to determine the clinico-radiographic efficacy of platelet-rich fibrin (PRF) and beta-tri-calcium phosphate with collagen (β-TCP-Cl) in preserving extraction sockets. For Group I (PRF), residual sockets (n = 15) were filled with autologous PRF obtained from patients' blood; and for Group II (β-TCP-Cl), residual sockets (n = 15) were filled with β-TCP-Cl. For the sockets randomly selected for Group II (β-TCP-Cl), the reshaped Resorbable Tissue Replacement cone was inserted into the socket. Clinically, there was a significantly greater decrease in relative socket depth, but apposition in midcrestal height in Group II (β-TCP-Cl) as compared to Group I (PRF), whereas more decrease in buccolingual width of Group I (PRF) than Group II (β-TCP-Cl) after 6 months. Radiographically, the mean difference in socket height, residual ridge, and width (coronal, middle, and apical third of socket) after 6 months was higher in Group I (PRF) as compared to Group II (β-TCP-Cl). The mean density (in Hounsfield Units) at coronal, middle, and apical third of socket was higher in Group I (PRF) as compared to Group II (β-TCP-Cl). There were statistically significant apposition and resorption for Group I (PRF) whereas nonsignificant resorption and significant apposition for Group II (β-TCP-Cl) in buccal and lingual/palatal cortical plate, respectively, at 6 months on computerized tomography scan. The use of either autologous PRF or β-TCP-Cl was effective in socket preservation. Results obtained from PRF were almost similar to β-TCP-Cl; therefore being autologous, nonimmune, cost-effective, easily procurable regenerative biomaterial, PRF proves to be an insight into the future biofuel for regeneration.
Quantification of rectifications for the Northwestern University Flexible Sub-Ischial Vacuum Socket.
Fatone, Stefania; Johnson, William Brett; Tran, Lilly; Tucker, Kerice; Mowrer, Christofer; Caldwell, Ryan
2017-06-01
The fit and function of a prosthetic socket depend on the prosthetist's ability to design the socket's shape to distribute load comfortably over the residual limb. We recently developed a sub-ischial socket for persons with transfemoral amputation: the Northwestern University Flexible Sub-Ischial Vacuum Socket. This study aimed to quantify the rectifications required to fit the Northwestern University Flexible Sub-Ischial Vacuum Socket to teach the technique to prosthetists as well as provide a computer-aided design-computer-aided manufacturing option. Development project. A program was used to align scans of unrectified and rectified negative molds and calculate shape change as a result of rectification. Averaged rectifications were used to create a socket template, which was shared with a central fabrication facility engaged in provision of Northwestern University Flexible Sub-Ischial Vacuum Sockets to early clinical adopters. Feedback regarding quality of fitting was obtained. Rectification maps created from 30 cast pairs of successfully fit Northwestern University Flexible Sub-Ischial Vacuum Sockets confirmed that material was primarily removed from the positive mold in the proximal-lateral and posterior regions. The template was used to fabricate check sockets for 15 persons with transfemoral amputation. Feedback suggested that the template provided a reasonable initial fit with only minor adjustments. Rectification maps and template were used to facilitate teaching and central fabrication of the Northwestern University Flexible Sub-Ischial Vacuum Socket. Minor issues with quality of initial fit achieved with the template may be due to inability to adjust the template to patient characteristics (e.g. tissue type, limb shape) and/or the degree to which it represented a fully mature version of the technique. Clinical relevance Rectification maps help communicate an important step in the fabrication of the Northwestern University Flexible Sub-Ischial Vacuum Socket facilitating dissemination of the technique, while the average template provides an alternative fabrication option via computer-aided design-computer-aided manufacturing and central fabrication.
Sewell, Philip; Noroozi, Siamak; Vinney, John; Amali, Ramin; Andrews, Stephen
2012-01-01
It has been recognised in a review of the developments of lower-limb prosthetic socket fitting processes that the future demands new tools to aid in socket fitting. This paper presents the results of research to design and clinically test an artificial intelligence approach, specifically inverse problem analysis, for the determination of the pressures at the limb/prosthetic socket interface during stance and ambulation. Inverse problem analysis is based on accurately calculating the external loads or boundary conditions that can generate a known amount of strain, stresses or displacements at pre-determined locations on a structure. In this study a backpropagation artificial neural network (ANN) is designed and validated to predict the interfacial pressures at the residual limb/socket interface from strain data collected from the socket surface. The subject of this investigation was a 45-year-old male unilateral trans-tibial (below-knee) traumatic amputee who had been using a prosthesis for 22 years. When comparing the ANN predicted interfacial pressure on 16 patches within the socket with actual pressures applied to the socket there is shown to be 8.7% difference, validating the methodology. Investigation of varying axial load through the subject's prosthesis, alignment of the subject's prosthesis, and pressure at the limb/socket interface during walking demonstrates that the validated ANN is able to give an accurate full-field study of the static and dynamic interfacial pressure distribution. To conclude, a methodology has been developed that enables a prosthetist to quantitatively analyse the distribution of pressures within the prosthetic socket in a clinical environment. This will aid in facilitating the "right first time" approach to socket fitting which will benefit both the patient in terms of comfort and the prosthetist, by reducing the time and associated costs of providing a high level of socket fit. Copyright © 2011 Elsevier B.V. All rights reserved.
Working Memory Is Partially Preserved during Sleep
Daltrozzo, Jérôme; Claude, Léa; Tillmann, Barbara; Bastuji, Hélène; Perrin, Fabien
2012-01-01
Although several cognitive processes, including speech processing, have been studied during sleep, working memory (WM) has never been explored up to now. Our study assessed the capacity of WM by testing speech perception when the level of background noise and the sentential semantic length (SSL) (amount of semantic information required to perceive the incongruence of a sentence) were modulated. Speech perception was explored with the N400 component of the event-related potentials recorded to sentence final words (50% semantically congruent with the sentence, 50% semantically incongruent). During sleep stage 2 and paradoxical sleep: (1) without noise, a larger N400 was observed for (short and long SSL) sentences ending with a semantically incongruent word compared to a congruent word (i.e. an N400 effect); (2) with moderate noise, the N400 effect (observed at wake with short and long SSL sentences) was attenuated for long SSL sentences. Our results suggest that WM for linguistic information is partially preserved during sleep with a smaller capacity compared to wake. PMID:23236418
Working memory is partially preserved during sleep.
Daltrozzo, Jérôme; Claude, Léa; Tillmann, Barbara; Bastuji, Hélène; Perrin, Fabien
2012-01-01
Although several cognitive processes, including speech processing, have been studied during sleep, working memory (WM) has never been explored up to now. Our study assessed the capacity of WM by testing speech perception when the level of background noise and the sentential semantic length (SSL) (amount of semantic information required to perceive the incongruence of a sentence) were modulated. Speech perception was explored with the N400 component of the event-related potentials recorded to sentence final words (50% semantically congruent with the sentence, 50% semantically incongruent). During sleep stage 2 and paradoxical sleep: (1) without noise, a larger N400 was observed for (short and long SSL) sentences ending with a semantically incongruent word compared to a congruent word (i.e. an N400 effect); (2) with moderate noise, the N400 effect (observed at wake with short and long SSL sentences) was attenuated for long SSL sentences. Our results suggest that WM for linguistic information is partially preserved during sleep with a smaller capacity compared to wake.
Socket welds in nuclear facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, P.A.; Torres, L.L.
1995-12-31
Socket welds are easier and faster to make than are butt welds. However, they are often not used in nuclear facilities because the crevices between the pipes and the socket sleeves may be subject to crevice corrosion. If socket welds can be qualified for wider use in facilities that process nuclear materials, the radiation exposures to welders can be significantly reduced. The current tests at the Idaho Chemical Processing Plant (ICPP) are designed to determine if socket welds can be qualified for use in the waste processing system at a nuclear fuel processing plant.
Leong, R.
1993-06-22
The invention is a receptacle for a three prong electrical plug which has either a tubular or U-shaped grounding prong. The inventive receptacle has a grounding prong socket which is sufficiently spacious to prevent the socket from significantly stretching when a larger, U-shaped grounding prong is inserted into the socket, and having two ridges to allow a snug fit when a smaller tubular shape grounding prong is inserted into the socket. The two ridges are made to prevent the socket from expanding when either the U-shaped grounding prong or the tubular grounding prong is inserted.
Leong, Robert
1993-01-01
The invention is a receptacle for a three prong electrical plug which has either a tubular or U-shaped grounding prong. The inventive receptacle has a grounding prong socket which is sufficiently spacious to prevent the socket from significantly stretching when a larger, U-shaped grounding prong is inserted into the socket, and having two ridges to allow a snug fit when a smaller tubular shape grounding prong is inserted into the socket. The two ridges are made to prevent the socket from expanding when either the U-shaped grounding prong or the tubular grounding prong is inserted.
Timperley, A John; Nusem, Iulian; Wilson, Kathy; Whitehouse, Sarah L; Buma, Pieter; Crawford, Ross W
2010-08-01
Our aim was to assess in an animal model whether the use of HA paste at the cement-bone interface in the acetabulum improves fixation. We examined, in sheep, the effect of interposing a layer of hydroxyapatite cement around the periphery of a polyethylene socket prior to fixing it using polymethylmethacrylate (PMMA). We performed a randomized study involving 22 sheep that had BoneSource hydroxyapatite material applied to the surface of the acetabulum before cementing a polyethylene cup at arthroplasty. We studied the gross radiographic appearance of the implant-bone interface and the histological appearance at the interface. There were more radiolucencies evident in the control group. Histologically, only sheep randomized into the BoneSource group exhibited a fully osseointegrated interface. Use of the hydroxyapatite material did not give any detrimental effects. In some cases, the material appeared to have been fully resorbed. When the material was evident in histological sections, it was incorporated into an osseointegrated interface. There was no giant cell reaction present. There was no evidence of migration of BoneSource to the articulation. The application of HA material prior to cementation of a socket produced an improved interface. The technique may be useful in humans, to extend the longevity of the cemented implant by protecting the socket interface from the effect of hydrodynamic fluid flow and particulate debris.
Energy Savings Potential of SSL in Horticultural Applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stober, Kelsey; Lee, Kyung; Yamada, Mary
Report that presents the findings for horticultural lighting applications where light-emitting diode (LED) products are now competing with traditional light sources. The three main categories of indoor horticulture were investigated: supplemented greenhouses, which use electric lighting to extend the hours of daylight, supplement low levels of sunlight on cloudy days, or disrupt periods of darkness to alter plant growth; non-stacked indoor farms, where plants are grown in a single layer on the floor under ceiling-mounted lighting; and vertical farms, where plants are stacked along vertical shelving to maximize grow space, and the lighting is typically mounted within the shelving units.
Rea, L.D.; Christ, A.M.; Hayden, A.B.; Stegall, V.K.; Farley, S.D.; Stricker, Craig A.; Mellish, J.E.; Maniscalco, John M.; Waite, J.N.; Burkanov, V.N.; Pitcher, K.W.
2015-01-01
Steller sea lions (SSL; Eumetopias jubatus) grow their vibrissae continually, providing a multiyear record suitable for ecological and physiological studies based on stable isotopes. An accurate age-specific vibrissae growth rate is essential for registering a chronology along the length of the record, and for interpreting the timing of ecologically important events. We utilized four methods to estimate the growth rate of vibrissae in fetal, rookery pup, young-of-the-year (YOY), yearling, subadult, and adult SSL. The majority of vibrissae were collected from SSL live-captured in Alaska and Russia between 2000 and 2013 (n = 1,115), however, vibrissae were also collected from six adult SSL found dead on haul-outs and rookeries during field excursions to increase the sample size of this underrepresented age group. Growth rates of vibrissae were generally slower in adult (0.44 ± 0.15 cm/mo) and subadult (0.61 ± 0.10 cm/mo) SSL than in YOY (0.87 ± 0.28 cm/mo) and fetal (0.73 ± 0.05 cm/mo) animals, but there was high individual variability in these growth rates within each age group. Some variability in vibrissae growth rates was attributed to the somatic growth rate of YOY sea lions between capture events (P = 0.014, r2 = 0.206, n = 29).
Pourafshar, Shirin; Rosentrater, Kurt A; Krishnan, Padmanaban G
2018-03-01
Bread is one of the oldest foods known throughout history and even though it is one of the principal types of staple around the world, it usually lacks enough nutrients, including protein and fiber. As such, fortification is one of the best solutions to overcome this problem. Thus, the objective this study was to examine the effect of three levels of distillers dried grains with solubles (DDGS) (0%, 10% and 20%) in conjunction with three levels of SSL (sodium stearoyl lactate) (0%, 2% and 5%) on physical and chemical properties of Barbari bread (traditional Iranian bread). To the best of our knowledge, this is the first study to evaluate DDGS and Sodium Stearoyl-2-Lactilate (SSL), as sources of fortification in Barbari bread. The results showed that incorporation of 20% of DDGS and 0% SSL caused a significant increase in the amount of fiber and protein. As for the physical attributes, using higher amount of DDGS caused a darker color, and as for the texture parameters, the highest firmness was measured when 10% DDGS and 5% of SSL were used. Different Mixolab and Rapid Visco Analyzer (RVA) parameters also were measured with varying results. The findings of this study show that DDGS can be a valuable source of fiber and protein, which can be used as a cost effective source to fortify cereal-based products.
Kobayashi, Toshiki; Orendurff, Michael S; Boone, David A
2013-09-27
The alignment of a lower-limb prosthesis is critical to the successful prosthetic fitting and utilization by the wearer. Loads generated by the socket applied to the residual limb while walking are thought to be different in transfemoral and knee-disarticulation prostheses. The aim of this case series was to compare the socket reaction moments between transfemoral and knee-disarticulation prostheses and to investigate the effect of alignment changes on them. Two amputees, one with a transfemoral prosthesis and another with a knee-disarticulation prosthesis, participated in this study. A Smart Pyramid™ was used to measure socket reaction moments while walking under 9 selected alignment conditions; including nominally aligned, angle malalignments of 6° (flexion, extension, abduction and adduction) and translation malalignments of 15 mm (anterior, posterior, medial and lateral) of the socket relative to the foot. This study found that the pattern of the socket reaction moments was similar between transfemoral and knee-disarticulation prostheses. An extension moment in the sagittal plane and a varus moment in the coronal plane were dominant during stance under the nominally aligned condition. This study also demonstrated that alignment changes might have consistent effects on the socket reaction moments in transfemoral and knee-disarticulation prostheses. Extension and posterior translation of the socket resulted in increases in an extension moment, while abduction and lateral translation of the socket resulted in increases in a varus moment. The socket reaction moments may potentially serve as useful biomechanical parameters to evaluate alignment in transfemoral and knee-disarticulation prostheses. Copyright © 2013 Elsevier Ltd. All rights reserved.
Characterization of interfacial socket pressure in transhumeral prostheses: A case series.
Schofield, Jonathon S; Schoepp, Katherine R; Williams, Heather E; Carey, Jason P; Marasco, Paul D; Hebert, Jacqueline S
2017-01-01
One of the most important factors in successful upper limb prostheses is the socket design. Sockets must be individually fabricated to arrive at a geometry that suits the user's morphology and appropriately distributes the pressures associated with prosthetic use across the residual limb. In higher levels of amputation, such as transhumeral, this challenge is amplified as prosthetic weight and the physical demands placed on the residual limb are heightened. Yet, in the upper limb, socket fabrication is largely driven by heuristic practices. An analytical understanding of the interactions between the socket and residual limb is absent in literature. This work describes techniques, adapted from lower limb prosthetic research, to empirically characterize the pressure distribution occurring between the residual limb and well-fit transhumeral prosthetic sockets. A case series analyzing the result of four participants with transhumeral amputation is presented. A Tekscan VersaTek pressure measurement system and FaroArm Edge coordinate measurement machine were employed to capture socket-residual limb interface pressures and geometrically register these values to the anatomy of participants. Participants performed two static poses with their prosthesis under two separate loading conditions. Surface pressure maps were constructed from the data, highlighting pressure distribution patterns, anatomical locations bearing maximum pressure, and the relative pressure magnitudes. Pressure distribution patterns demonstrated unique characteristics across the four participants that could be traced to individual socket design considerations. This work presents a technique that implements commercially available tools to quantitatively characterize upper limb socket-residual limb interactions. This is a fundamental first step toward improved socket designs developed through informed, analytically-based design tools.
Characterization of interfacial socket pressure in transhumeral prostheses: A case series
Schoepp, Katherine R.; Williams, Heather E.; Carey, Jason P.; Marasco, Paul D.
2017-01-01
One of the most important factors in successful upper limb prostheses is the socket design. Sockets must be individually fabricated to arrive at a geometry that suits the user’s morphology and appropriately distributes the pressures associated with prosthetic use across the residual limb. In higher levels of amputation, such as transhumeral, this challenge is amplified as prosthetic weight and the physical demands placed on the residual limb are heightened. Yet, in the upper limb, socket fabrication is largely driven by heuristic practices. An analytical understanding of the interactions between the socket and residual limb is absent in literature. This work describes techniques, adapted from lower limb prosthetic research, to empirically characterize the pressure distribution occurring between the residual limb and well-fit transhumeral prosthetic sockets. A case series analyzing the result of four participants with transhumeral amputation is presented. A Tekscan VersaTek pressure measurement system and FaroArm Edge coordinate measurement machine were employed to capture socket-residual limb interface pressures and geometrically register these values to the anatomy of participants. Participants performed two static poses with their prosthesis under two separate loading conditions. Surface pressure maps were constructed from the data, highlighting pressure distribution patterns, anatomical locations bearing maximum pressure, and the relative pressure magnitudes. Pressure distribution patterns demonstrated unique characteristics across the four participants that could be traced to individual socket design considerations. This work presents a technique that implements commercially available tools to quantitatively characterize upper limb socket-residual limb interactions. This is a fundamental first step toward improved socket designs developed through informed, analytically-based design tools. PMID:28575012
Haraji, Afshin; Rakhshan, Vahid; Khamverdi, Naiemeh; Alishahi, Hadiseh Khanzadeh
2013-01-01
To assess the effects of intra-alveolar application of chlorhexidine gel on the incidence of alveolar osteitis (dry socket) and the severity of postsurgical pain. A total of 160 impacted mandibular third molars were extracted in 80 patients enrolled in this trial. In each subject, a socket was randomly selected and packed to the crest of the alveolar ridge with a gelatin sponge dressing saturated in 0.2% chlorhexidine gel. The contralateral socket was packed with a dry dressing as the placebo. None of the included patients took antibiotics or analgesics. The occurrence of dry socket and patients' pain levels were assessed at the first and third postoperative days. The data were analyzed using Spearman correlation coefficient, McNemar, Wilcoxon, and chi-square tests. Chlorhexidine gel significantly reduced dry socket incidence from 32.6% to 11.3% (P ≤ .001 [McNemar and chi-square], absolute risk reduction = 21.2%, relative risk reduction = 65.4%, odds ratio = 0.263, relative risk = 0.345). It also significantly relieved postoperative pain on both sides in all the patients (P ≤ .001 [Wilcoxon]) and also in the 54 subjects who did not develop dry socket (P ≤ .001 [Wilcoxon]). Besides decreasing the incidence of dry socket, chlorhexidine gel can reduce postsurgical pain in patients with and without dry socket.
A smartphone photogrammetry method for digitizing prosthetic socket interiors.
Hernandez, Amaia; Lemaire, Edward
2017-04-01
Prosthetic CAD/CAM systems require accurate 3D limb models; however, difficulties arise when working from the person's socket since current 3D scanners have difficulties scanning socket interiors. While dedicated scanners exist, they are expensive and the cost may be prohibitive for a limited number of scans per year. A low-cost and accessible photogrammetry method for socket interior digitization is proposed, using a smartphone camera and cloud-based photogrammetry services. 15 two-dimensional images of the socket's interior are captured using a smartphone camera. A 3D model is generated using cloud-based software. Linear measurements were comparing between sockets and the related 3D models. 3D reconstruction accuracy averaged 2.6 ± 2.0 mm and 0.086 ± 0.078 L, which was less accurate than models obtained by high quality 3D scanners. However, this method would provide a viable 3D digital socket reproduction that is accessible and low-cost, after processing in prosthetic CAD software. Clinical relevance The described method provides a low-cost and accessible means to digitize a socket interior for use in prosthetic CAD/CAM systems, employing a smartphone camera and cloud-based photogrammetry software.
Fatigue evaluation of socket welded piping in nuclear power plant
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vecchio, R.S.
1996-12-01
Fatigue failures in piping systems occur, almost without exception, at the welded connections. In nuclear power plant systems, such failures occur predominantly at the socket welds of small diameter piping ad fillet attachment welds under high-cycle vibratory conditions. Nearly all socket weld fatigue failures are identified by leaks which, though not high in volume, generally are costly due to attendant radiological contamination. Such fatigue cracking was recently identified in the 3/4 in. diameter recirculation and relief piping socket welds from the reactor coolant system (RCS) charging pumps at a nuclear power plant. Consequently, a fatigue evaluation was performed to determinemore » the cause of cracking and provide an acceptable repair. Socket weld fatigue life was evaluated using S-N type fatigue life curves for welded structures developed by AASHTO and the assessment of an effective cyclic stress range adjacent to each socket weld. Based on the calculated effective tress ranges and assignment of the socket weld details to the appropriate AASHTO S-N curves, the socket weld fatigue lives were calculated and found to be in excellent agreement with the accumulated cyclic life to-date.« less
Computer design synthesis of a below knee-Syme prosthesis
NASA Technical Reports Server (NTRS)
Elangovan, P. T.; Ghista, D. N.; Alwar, R. S.
1979-01-01
A detailed design synthesis analysis of the BK Syme prosthesis is provided, to determine the socket's cutout orientation size and shape, cutout fillet shape, socket wall thickness distribution and the reinforced fiber distribution in the socket wall, for a minimally stressed structurally safe lightweight prosthesis. For analysis purposes, the most adverse socket loading is obtained at the push-off stage of gait; this loading is idealized as an axial in-plane loading on the bottom edge of the circular cylindrical socket shell whose top edge is considered fixed. Finite element stress analysis of the socket shell (with uniform and graded wall thickness) are performed for various orientations of the cutout and for various types of corner fillets. A lateral cutout with a streamline fillet is recommended. The wall material (i.e., thickness) distribution is determined so as to minimize the stresses, while ensuring that the wall material's stress limits are not exceeded. For such a maximally stressed lightweight socket shell, the panels in the neighborhood of the cutout are checked to ensure that they do not buckle under their acquired stresses. A fiber-reinforced laminated composite socket shell is also analyzed in order to recommend optimum variables in orientations and densities of reinforcing fibers.
Socket stars: UBVRJIK radial profiles
NASA Astrophysics Data System (ADS)
Schaefer, Bradley E.
1995-05-01
Visual inspectin of stars embedded in H II nebulae has shown a significant fraction to be surrounded by nearly symmetric extended regions within which the nebular brightness is apparently significantly fainter than is typical for the surrounding area. These 'socket stars' might be caused by a bubble in the nebula blown out by a stellar wind or they might be caused by a circumstellar envelope of dust hiding the emission behind the star. As such, the sockets could be the first manifestation of a previously unknown component of pre-main-sequence stars. Unfortunately, no quantitative proof of the existence of sockets has been presented. To fill this need, I have imaged 10 socket stars and six background stars with CCD cameras and infrared array cameras. From these images, I have constructed radial plots which should reveal dips in brightness immediately outside the seeing disk. The radial plots do not show any evidence for the existence of sockets. A detailed examination of the photographs orginally used to identify the sockets show that the causes of these reports are (1) artifacts resulting from the photographic process of dodging and (2) random coincidence of stars with local minima in nebular brightness. Thus, I conclude that 'socket stars' do not exist.
Robot friendly probe and socket assembly
NASA Technical Reports Server (NTRS)
Nyberg, Karen L. (Inventor)
1994-01-01
A probe and socket assembly for serving as a mechanical interface between structures is presented. The assembly comprises a socket having a housing adapted for connection to a first supporting structure and a probe which is readily connectable to a second structure and is designed to be easily grappled and manipulated by a robotic device for insertion and coupling with the socket. Cooperable automatic locking means are provided on the probe shaft and socket housing for automatically locking the probe in the socket when the probe is inserted a predetermined distance. A second cooperable locking means on the probe shaft and housing are adapted for actuation after the probe has been inserted the predetermined distance. Actuation means mounted on the probe and responsive to the grip of the probe handle by a gripping device, such as a robot for conditioning the probe for insertion and are also responsive to release of the grip of the probe handle to actuate the second locking means to provide a hard lock of the probe in the socket.
Jambhekar, Shantanu; Kernen, Florian; Bidra, Avinash S
2015-05-01
Several biomaterials and techniques have been reported for socket grafting and alveolar ridge preservation. However, the evidence for clinical and histologic outcomes for socket grafting with different types of materials in flapless extraction is not clear. The purpose of this systematic review was to analyze the outcomes of a socket grafting procedure performed with flapless extraction of teeth in order to determine which graft material results in the least loss of socket dimensions, the maximum amount of vital bone, the least remnant graft material, and the least amount of connective tissue after a minimum of 12 weeks of healing. Secondary outcomes, including the predictability of regenerating deficient buccal bone, necessity of barrier membranes, and coverage with autogenous soft tissue graft, were also evaluated. An electronic search for articles in the English-language literature was performed independently by multiple investigators using a systematic search process with the PubMed search engine. After applying predetermined inclusion and exclusion criteria, the final list of randomized controlled clinical trials (RCTs) for flapless extraction and socket grafting was analyzed to derive results for the various objectives of the study. The initial electronic search resulted in 2898 titles. The systematic application of inclusion and exclusion criteria resulted in 32 RCTs studying 1354 sockets, which addressed the clinical and histologic outcomes of flapless extraction with socket grafting and provided dimensional and histologic information at or beyond the 12-week reentry period. From these RCTs, the mean loss of buccolingual width at the ridge crest was lowest for xenografts (1.3 mm), followed by allografts (1.63 mm), alloplasts (2.13 mm), and sockets without any socket grafting (2.79 mm). Only 3 studies reported on loss of width at 3 mm below the ridge crest. The mean loss of buccal wall height from the ridge crest was lowest for xenografts (0.57 mm) and allografts (0.58 mm), followed by alloplasts (0.77 mm) and sockets without any grafting (1.74 mm). The mean histologic outcomes at or beyond the 12-week reentry period revealed the highest vital bone content for sockets grafted with alloplasts (45.53%), followed by sockets with no graft material (41.07%), xenografts (35.72%), and allografts (29.93%). The amount of remnant graft material was highest for sockets grafted with allografts (21.75%), followed by xenografts (19.3%) and alloplasts (13.67%). The highest connective tissue content at the time of reentry was seen for sockets with no grafting (52.53%), followed by allografts (51.03%), xenografts (44.42%), and alloplast (38.39%). Data for new and emerging biomaterials such as cell therapy and tissue regenerative materials were not amenable to calculations because of biomaterial heterogeneity and small sample sizes. After flapless extraction of teeth, and using a minimum healing period of 12 weeks as a temporal measure, xenografts and allografts resulted in the least loss of socket dimensions compared to alloplasts or sockets with no grafting. Histologic outcomes after a minimum of 12 weeks of healing showed that sockets grafted with alloplasts had the maximum amount of vital bone and the least amount of remnant graft material and remnant connective tissue. There is a limited but emerging body of evidence for the predictable regeneration of deficient buccal bone with socket grafting materials, need for barrier membranes, use of tissue engineering, and use of autogenous soft tissue grafts from the palate to cover the socket. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
SSL Pricing and Efficacy Trend Analysis for Utility Program Planning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tuenge, J. R.
2013-10-01
Report to help utilities and energy efficiency organizations forecast the order in which important SSL applications will become cost-effective and estimate when each "tipping point" will be reached. Includes performance trend analysis from DOE's LED Lighting Facts® and CALiPER programs plus cost analysis from various sources.
Random Fill Cache Architecture (Preprint)
2014-10-01
a concrete example, we show how the cache collision attack works to extract the AES encryption keys (e.g., in the OpenSSL implementation of AES). AES...each round are implemented as table lookups for performance reasons. OpenSSL uses ten 1-KB lookup tables, five for encryption and five for decryption
SSL Adoption by Museums: Survey Results, Analysis, and Recommendations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perrin, T. E.; Druzik, J. R.; Miller, N. J.
DOE Solid-State Lighting GATEWAY report that summarizes the results of a survey of the museum community regarding conversions to SSL in museums. Responses provided real-world insight into how LEDs are being incorporated into museums, and what successes and hurdles have been encountered in the process.
Technical Risk Identification at Program Inception Product Overview
2014-05-08
hans.koenigsmann@spacex.com SpaceX James Koory james.koory@rocket.com Rocket Brian Kosinski Kosinski.Brian@ssd.loral.com SSL John Kowalchik john.j.kowalchik...Marvin VanderWeg marvin.vanderwag@spacex.com SpaceX Gerrit VanOmmering gerrit.vanommering@sslmda.com SSL Michael Verzuh mverzuh@ball.com Ball John Vilja
Root Cause Investigation Best Practices Guide
2014-05-30
Koenigsmann hans.koenigsmann@spacex.c om SpaceX James Koory james.koory@rocket.com Rocket Brian Kosinski Kosinski.Brian@ssd.loral.co m SSL John...Fred Van Milligen fvanmilligen@jdsu.com JDSU Marvin VanderWeg marvin.vanderwag@spacex.c om SpaceX Gerrit VanOmmering gerrit.vanommering@sslmda. com SSL
RF Breakdown Prevention in Spacecraft Components Product Overview
2014-05-08
Koenigsmann SpaceX hans.koenigsmann@spacex.com James Koory Rocket james.koory@rocket.com Brian Kosinski SSL Kosinski.Brian@ssd.loral.com John Kowalchik...fvanmilligen@jdsu.com Marvin VanderWeg SpaceX marvin.vanderwag@spacex.com Gerrit VanOmmering SSL gerrit.vanommering@sslmda.com Michael Verzuh Ball mverzuh
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lall, Pradeep; Sakalaukus, Peter; Davis, Lynn
2015-07-06
Today’s lighting technology is steadily becoming more energy efficient and less toxic to the environment since the passing of the Energy Independence and Security Act of 2007 (EISA) [1]. EISA has mandated a higher energy efficiency standard for lighting products and the phase out of the common incandescent lamp. This has led lighting manufacturers to pursue solid-state lighting (SSL) technologies for consumer lighting applications. However, two major roadblocks are hindering the transition process to SSL lamps: cost and quality. In order to cut cost, manufactures are moving towards cheaper packaging materials and a variety of package architecture construction techniques whichmore » may potentially erode the quality of the lamp and reduce its survivability in everyday applications. Typically, SSL lamps are given product lifetimes of over twenty years based off of the IES TM-21-11 lighting standard which does not include moisture effects or large operational temperatures [2]. A group of recently released off-the-shelf lamps have undergone a steady-state temperature humidity bias life test of 85°C/85%RH (85/85) to investigate the reliability in harsh environment applications. The lack of accelerated test methods for lamps to assess reliability prior to introduction into the marketplace does not exist in literature. There is a need for SSL physics based models for the assessment and prediction of a lamp’s lifetime which is being spearheaded by the DOE [3]. In order to be fully accepted in the marketplace, SSL lamps must be able to perform similarly to incandescent lamps in these environments, as well as live up to the lifetime claims of manufacturers. A lamp’s package architecture must be designed with performance factors in mind, as well as address some of the known and published package related failure mechanisms, such as carbonization of the encapsulant material, delamination, encapsulant yellowing, lens cracking, and phosphor thermal quenching [4]. Each failure mechanism produces the similar failure mode of lumen degradation predominately due to two contributing factors: high junction temperature and moisture ingress. The current state-of-the-art has focused on individual areas of the lamp, such as the LED chip, substrate material, electrical driver design and thermal management techniques. [5] – [16] Looking at the lamp as a whole is a novel approach and has not been seen before in literature. This work followed the JEDEC standard JESD22-A101C of 85/85 with a one hour interval of applied voltage followed by a one hour interval of no applied voltage [17]. This test was performed continuously for each SSL lamp until it became nonoperational, i.e. did not turn on. Periodically, photometric measurements were taken following the IES LM-79-08 standard at room temperature using an integrating sphere, a spectrometer, and lighting software. The overall health of the SSL lamps was assed using the relative luminous flux (RLF), correlated color temperature (CCT) and the color difference (Δu'v') using the Euclidean distance of the CIE 1976 color space coordinates. Finally, a Weibull analysis was completed to compare the characteristic lifetime of the SSL lamp to the actual rated lifetime. An important result from this work shows that the rated lifetime does not come close to the actual lifetime when the SSL lamps are used in a harsh humid environment which is fairly common in outdoor applications across the U.S. Also, the photometric results are presented for the entire lifetime of each SSL lamp under test.« less
Umlauf, Gunther; Christoph, Eugen H; Lanzini, Laura; Savolainen, Risto; Skejo, Helle; Bidoglio, Giovanni; Clemens, Joachim; Goldbach, Heiner; Scherer, Heinrich
2011-03-01
Biowaste contains compounds of agricultural value such as organic carbon, nutrients, and trace elements and can partially replace mineral fertilizer (MIN) and improve the physical properties of the soil. However, the obvious benefits of land spreading need to be carefully evaluated against potential adverse effects on the environment and human health. Environmental contamination resulting from biowaste application is one of the key variables when assessing cost/benefits. This study provides data on the resulting concentration of polychlorinated dibenzodioxins and dibenzofurans (PCDD/Fs) and dioxin-like polychlorinated biphenyls (DL-PCBs) in the soil column as a result of the different types of fertilizers. In a long-term field experiment established in 1962, we investigated the influence of the application of biowaste-derived fertilizers such as sewage sludge (SSL), compost (COM), and farmyard manure (FYM) to a luvisol derived from loess on the contents of PCDD/Fs and DL-PCBs. Control plots amended only with MIN served as a basis to compare the biowaste-amended soils with soils affected only by atmospheric deposition, thus experimentally separating the two pathways of soil contamination. Samples of the soil column down to a depth of 90 cm were taken in 2001 and analyzed for PCDD/Fs and dioxin-like PCBs according to US-EPA methods 1613 and 1668, respectively. Thirty-nine years of experimental SSL and COM applications exceeding four times the maximal amount as laid down in German legislation resulted in a doubling of the international toxicity equivalent (I-TEQ) budget for PCDD/Fs and a threefold increase for DL-PCBs as compared to test plots amended with MIN only. As compared to MIN, the application of FYM had no effect on the PCDD/F and PCB content in soil. The average contribution of the DL-PCBs to the WHO-TEQ was 19% in the MIN and FYM plots and somewhat higher in the COM (23%) and in the SSL (27%) plots. Although the test plots received four times the maximum application of SSL as laid down in the German SSL ordinance and the investigated region represents the upper end of the topsoil concentrations typically found in Germany, the soils treated with SSL and COM were still a factor of 4 below the German guideline value of PCDD/Fs for arable land. No enhancement of translocation of PCDD/Fs and PCBs into the corresponding subsoils due to the presence of dissolved humic matter or other surfactants potentially present in the biowaste was observed. The similarity of congener patterns in all soils, irrespective of the type of fertilizer applied, points towards atmospheric deposition of PCDD/Fs and DL-PCBs as the main intake route in the soils. The higher levels in the SSL- and COM-amended soils can be explained by the fact that both biowastes are subject to atmospheric deposition occurring at their origin. In the case of COM, it is accumulation in the foliage, while in the case of SSL, atmospheric particulate from wet and dry deposition is collected in the wastewater treatment system via urban runoff. It appears that the common practice of SSL applications in Germany does not pose a current threat to the agro-environment with regard to PCDD/Fs and DL-PCBs. However, time trend data on PCDD/Fs in SSL-amended soils will be needed to obtain a prognosis about the long-term effect of biowaste applications on soil quality.
Tethering sockets and wrenches
NASA Technical Reports Server (NTRS)
Johnson, E. P.
1990-01-01
The tethering of sockets and wrenches was accomplished to improve the safety of working over motor segments. To accomplish the tethering of the sockets to the ratchets, a special design was implemented in which a groove was machined into each socket. Each socket was then fitted with a snap ring that can spin around the machined groove. The snap ring is tethered to the handle of the ratchet. All open end wrenches are also tethered to the ratchet or to the operator, depending upon the type. Tests were run to ensure that the modified tools meet torque requirements. The design was subsequently approved by Space Safety.
Fee, L
2017-04-21
Socket preservation maintains bone volume post-extraction in anticipation of an implant placement or fixed partial denture pontic site. This procedure helps compensate for the resorption of the facial bone wall. Socket preservation should be considered when implant placement needs to be delayed for patient or site-related reasons. The ideal healing time before implant placement is six months. Socket preservation can reduce the need for later bone augmentation. By reducing bone resorption and accelerating bone formation it increases implant success and survival. Biomaterials for socket grafting including autograft, allograft, xenograft and alloplast. A bone substitute with a low substitution rate is recommended.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-15
... with medium screw base sockets, as well as pin-based sockets. (42 U.S.C. 6295(ff)(2)-(3)) The statute... (including candelabra screw base sockets) by January 1, 2007, and if DOE failed to issue such standards by... standards for light kits with sockets other than medium-screw base or pin-based fluorescent lamps in the CFR...
Timeframe of socket cortication after tooth extraction: A retrospective radiographic study.
Bertl, Kristina; Kukla, Edmund Benjamin; Albugami, Rajaa; Beck, Florian; Gahleitner, André; Stavropoulos, Andreas
2018-01-01
To assess the timeframe between tooth extraction and radiographically detectable socket cortication in humans. Two hundred and fifty patients with a CT scan ≤36 months after tooth extraction were included. First, three orthoradial multiplanar reconstruction slices, representing the major part of the extraction socket, were scored regarding the degree of bone healing as (i) healed, that is, complete/continuous cortication of the socket entrance, or (ii) non-healed. Thereafter, based on the results of all three slices, the stage of cortication of the extraction socket, as one unit, was classified as (i) non-corticated, that is, all three slices judged as non-healed, (ii) partially corticated, that is, 1 or 2 slices judged as non-healed, or (iii) completely corticated, that is, all three slices judged as healed. The possible effect of several independent parameters, that is, age, gender, timeframe between tooth extraction and CT scan, tooth type, extent of radiographic bone loss of the extracted tooth, tooth-gap type, smoking status, presence of any systemic disease, and medication intake, on cortication status was statistically evaluated. Three to 6 months after tooth extraction, 27% of the sockets were judged as non-corticated and 53% were judged as partially corticated. After 9-12 months, >80% of the sockets were corticated, while some incompletely corticated sockets were detected up to 15 months after extraction. Each additional month after tooth extraction contributed significantly to a higher likelihood of a more advanced stage of cortication, while radiographic bone loss ≥75% significantly prolonged cortication time; no other independent variable had a significant effect. The results indicate a considerably long timeframe until complete cortication of an extraction socket, that is, 3-6 months after tooth extraction 3 of 4 sockets were still not completely corticated, and only after 9-12 months, complete cortication was observed in about 80% of the sockets. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Girish Kumar, N; Chaudhary, Rupanzal; Kumar, Ish; Arora, Srimathy S; Kumar, Nilesh; Singh, Hem
2018-06-01
The purpose of this study is to evaluate the efficacy of Platelet Rich Fibrin (PRF) as a socket plug with or without use of Plaster of Paris (POP) as bone substitute to preserve the alveolar ridge post-extraction. A prospective randomised single blind controlled study, was conducted for 18 months from November 2014 to May 2016 on 48 patients requiring extraction. All teeth were extracted atraumatically using periotomes and luxators without raising mucoperiosteal flap. Sockets were randomly allotted to groups A, B and C. Group A sockets were chosen as control, where figure of eight suture was placed. In group B sockets, PRF obtained by centrifugation was used as a socket plug and stabilised with figure of eight suture. Group C sockets were filled with POP and then covered with PRF. The socket was then closed with a figure of eight suture. Patients were informed of need for 6 months follow-up. Ninety sockets in 48 patients were subjected to our study. We found that results in the sockets where we have grafted POP showed better ridge preservation and post-operative comfort even though the difference in ridge resorption between the three groups was not statistically significant. Powered by Editorial Manager® and ProduXion Manager® from the Aries Systems Corporation. Atraumatic extraction may minimise the post-operative pain and discomfort to patient as well as the post-extraction alveolar height and width changes. The use of PRF and/or bone substitute even though clinically contributes to better post-operative healing and minimal loss of alveolar width and height, the values were not statistically significant.
Finite element analysis of the contact interface between trans-femoral stump and prosthetic socket.
Zhang, Linlin; Zhu, Ming; Shen, Ling; Zheng, Feng
2013-01-01
Transfemoral amputees need prosthetic devices after amputation surgery, and the interface pressure between the residual limb and prosthetic socket has a significant effect on an amputee's satisfaction and comfort. The purpose of this study was to build a nonlinear finite element model to investigate the interface pressure between the above-knee residual limb and its prosthetic socket. The model was three-dimensional (3D) with consideration of nonlinear boundary conditions. Contact analysis was used to simulate the friction conditions between skin and the socket. The normal stresses up to 80.57 kPa at the distal end of the soft tissue. The longitudinal and circumferential shear stress distributions at the limb-socket interface were also simulated. This study explores the influences of load transfer between trans-femoral residual limb and its prosthetic socket.
CAD/CAM transtibial prosthetic sockets from central fabrication facilities: How accurate are they?
Sanders, Joan E.; Rogers, Ellen L.; Sorenson, Elizabeth A.; Lee, Gregory S.; Abrahamson, Daniel C.
2014-01-01
This research compares transtibial prosthetic sockets made by central fabrication facilities with their corresponding American Academy of Orthotists and Prosthetists (AAOP) electronic shape files and assesses the central fabrication process. We ordered three different socket shapes from each of 10 manufacturers. Then we digitized the sockets using a very accurate custom mechanical digitizer. Results showed that quality varied considerably among the different manufacturers. Four of the companies consistently made sockets within +/−1.1% volume (approximately 1 sock ply) of the AAOP electronic shape file, while six other companies did not. Six of the companies showed consistent undersizing or oversizing in their sockets, which suggests a consistent calibration or manufacturing error. Other companies showed inconsistent sizing or shape distortion, a difficult problem that represents a most challenging limitation for central fabrication facilities. PMID:18247236
Clinical and histologic outcomes of calcium sulfate in the treatment of postextraction sockets.
Ruga, Emanuele; Gallesio, Cesare; Chiusa, Luigi; Boffano, Paolo
2011-03-01
The aim of this prospective study was to assess the clinical and histologic outcomes obtained with calcium sulfate (CS) used as a filler material in fresh premolar and molar postextraction sockets. Sixty premolar or molar postextraction sockets were filled with CS. Among the 60 grafted sockets, after 3 months, 50 underwent implant placement and clinical assessment. The removal of a sample core of newly generated intrasocket tissue was performed in 19 sockets. Collected samples were sent for histologic examination. The percentage of vital bone, nonvital bone, residual CS, amorphous material, and connective areas in every sample was calculated and recorded. Fifty postextraction regenerated sockets that underwent implant placement 3 months after tooth removal were included in this study.A partial postoperative exposition of the graft was observed in 12 of 50 sockets. At the surgical reentry, the augmented extraction sockets were completely filled by a hard material with an adequate alveolar crest in 41 cases. Histologic examination of the cores revealed that 63.16% of the intrasocket tissue was new vital bone, 2.1% was nonvital bone, 4.74% was fibrous tissue, and 30% was amorphous material. No residual CS was identified in bone cores. This study confirmed that CS is an ideal grafting material. The clinical adequacy aspect of filled sockets at surgical reentry seemed to be indicative of a qualitatively better bone regeneration. Postoperative exposition of graft material after a first intervention seemed to constitute an important risk factor for a worse bone regeneration.
NASA Technical Reports Server (NTRS)
Green, Chris; Greenwell, Chris; Brusse, jay; Krus, Dennis; Leidecker, Henning
2009-01-01
During system level testing intermittent and permanent open circuit failures of mated, crimp removable, electrical contact pairs were experienced. The root cause of the failures was determined to be low (but not zero) contact forces applied by the socket contact tines against the engaging pin. The low contact force reduces the effectiveness of the wiping action of the socket tines against the pin. The observed failure mode may be produced when insufficient wiping during mate, demate and small relative movement in use allows for the accumulation of debris or insulating films that electrically separate the contact pair. The investigation identified at least three manufacturing process control problems associated with the socket contacts that enabled shipment of contacts susceptible to developing low contact forces: (1) Improper heat treatment of the socket tines resulting in plastic rather than elastic behavior; (2) Overly thinned socket tines at their base resulting in reduced pin retention forces; (3) insufficient screening tests to identify parts susceptible to the aforementioned failure mechanisms. The results from an extensive screening program of socket contacts utilizing the industry standard contact separation force test procedures are described herein. The investigation shows this method to be capable of identifying initially weak sockets. However, sockets whose contact retention forces may degrade during use may not be screened out by pin retention testing alone. Further investigations are required to correlate low contact retention forces with increased electrical contact resistance in the presence of insulating films that may accumulate in the use environment.
Kobayashi, Toshiki; Orendurff, Michael S; Zhang, Ming; Boone, David A
2014-05-01
The alignment of transtibial prostheses has a systematic effect on the mean socket reaction moments in amputees. However, understanding their individual differences in response to alignment perturbations is also important for prosthetists to fully utilize the socket reaction moments for dynamic alignment in each unique patient. The aim of this study was to investigate individual responses to alignment perturbations in transtibial prostheses with solid-ankle-cushion-heel feet. A custom instrumented prosthesis alignment component was used to measure the socket reaction moments while walking in 11 amputees with transtibial prostheses under 17 alignment conditions, including 3° and 6° of flexion, extension, abduction, and adduction of the socket, 5mm and 10mm of anterior, posterior, lateral, and medial translation of the socket, and an initial baseline alignment. Coronal moments at 30% of stance and maximum sagittal moments were extracted for comparisons from each amputee. In the coronal plane, varus moment at 30% of stance was generally reduced by adduction or medial translation of the socket in all the amputees. In the sagittal plane, extension moment was generally increased by posterior translation or flexion of the socket; however, this was not necessarily the case for all the amputees. Individual responses to alignment perturbations are not always consistent, and prosthetists would need to be aware of this variance when addressing individual socket reaction moments during dynamic alignment in clinical setting. Copyright © 2014 Elsevier Ltd. All rights reserved.
Histologic effects of intentional-socket-assisted orthodontic movement in rabbits.
Yu, Ji-Yeon; Lee, Won; Park, Jae Hyun; Bayome, Mohamed; Kim, Yong; Kook, Yoon-Ah
2012-08-01
This study aimed to evaluate the effect of an intentionally created socket on bone remodeling with orthodontic tooth movement in rabbits. Eighteen male rabbits weighing 3.8 - 4.25 kg were used. An 8-mm deep and 2-mm wide socket was drilled in the bone 1 mm mesial to the right mandibular first premolar. The left first premolar was extracted to serve as an extraction socket. A traction force of 100 cN was applied to the right first premolar and left second premolar. Sections were obtained at the middle third of the moving tooth for both the drilled and extraction sockets and evaluated with hematoxylin and eosin staining and immunohistochemical analyses. The amount of tooth movement and tartrate-resistant acid phosphatase (TRAP)-positive cell count were compared between the 2 groups using the Mann-Whitney U test. At week 2, the distance of tooth movement was significantly higher in the intentional socket group (p < 0.05) than in the extraction socket group. The number of TRAP-positive cells decreased in week 2 but increased in week 3 (p < 0.05). However, there were no significant differences between the groups. Furthermore, results of transforming growth factor (TGF)-β staining revealed no significant differences. The intentional socket group showed greater distance of tooth movement than did the extraction socket group at week 2. Osteoclast counts and results of immunohistochemical analyses suggested elevated bone remodeling in both the groups. Thus, osteotomy may be an effective modality for enhancing tooth movement in orthodontic treatment.
Fickl, Stefan; Zuhr, Otto; Wachtel, Hannes; Kebschull, Moritz; Hürzeler, Markus B
2009-10-01
The aim of this study was to histometrically assess alterations of the ridge following socket preservation alone and socket preservation with additional buccal overbuilding. In five beagle dogs four extraction sites were randomly subjected to one of the following treatments: Tx 1: The socket was filled with BioOss Collagen and covered with a free gingival graft from the palate. Tx 2: The buccal bone plate was augmented using the GBR-technique, the socket was filled with BioOss Collagen and covered with a free gingival graft. Tx 3: The buccal bone plate was forced into a buccal direction using a manual bone spreader. The socket was filled with BioOss Collagen and covered with a free gingival graft from the palate. Tx 4: The socket was filled with BioOss Collagen and a combined free gingival/connective tissue graft was used to cover the socket and for buccal tissue augmentation. For each experimental site, two histological sections were subjected to histometric analysis and evaluated for (i) vertical bone dimensions and (ii) horizontal bone dimensions. All treatment groups showed horizontal and vertical bone loss. The mean vertical bone loss of the buccal bone plate was significantly lower in Tx 4 than in the other groups, while no statistical significant differences could be detected among the groups in the horizontal dimension. Overbuilding the buccal aspect in combination with socket preservation does not seem to be a suitable technique to compensate for the alterations after tooth extraction.
Johansson, Emma; Brandberg, Tomas; Larsson, Christer
2011-11-01
The cell viability and fermentation performance often deteriorate in fermentations of spent sulphite liquor (SSL). This investigation therefore addresses the question of how different cultivation conditions for yeast cells influence their ability to survive and boost the ethanol production capacity in an SSL-based fermentation process. The strains used as pitching agents were an industrially harvested Saccharomyces cerevisiae and commercial dry baker's yeast. This study therefore suggests that exposure to SSL in combination with nutrients, prior to the fermentation step, is crucial for the performance of the yeast. Supplying 0.5 g/l fresh yeast cultivated under appropriate cultivation conditions may increase ethanol concentration more than 200%.
2014-10-01
Award Number: W81XWH-10-1-0744 TITLE: Development of Subischial Prosthetic Sockets with Vacuum...REPORT TYPE Annual 3. DATES COVERED 15 Sep 2013 – 14 Sep 2014 4. TITLE AND SUBTITLE Development of Subischial Prosthetic Sockets with Vacuum...to develop a highly flexible sub-ischial prosthetic socket with assisted-vacuum suspension for highly active persons with transfemoral amputation. The
Tang, Jinghua; McGrath, Michael; Laszczak, Piotr; Jiang, Liudi; Bader, Dan L; Moser, David; Zahedi, Saeed
2015-12-01
Design and fitting of artificial limbs to lower limb amputees are largely based on the subjective judgement of the prosthetist. Understanding the science of three-dimensional (3D) dynamic coupling at the residuum/socket interface could potentially aid the design and fitting of the socket. A new method has been developed to characterise the 3D dynamic coupling at the residuum/socket interface using 3D motion capture based on a single case study of a trans-femoral amputee. The new model incorporated a Virtual Residuum Segment (VRS) and a Socket Segment (SS) which combined to form the residuum/socket interface. Angular and axial couplings between the two segments were subsequently determined. Results indicated a non-rigid angular coupling in excess of 10° in the quasi-sagittal plane and an axial coupling of between 21 and 35 mm. The corresponding angular couplings of less than 4° and 2° were estimated in the quasi-coronal and quasi-transverse plane, respectively. We propose that the combined experimental and analytical approach adopted in this case study could aid the iterative socket fitting process and could potentially lead to a new socket design. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Safari, Mohammad Reza; Meier, Margrit Regula
2015-01-01
This review is an attempt to untangle the complexity of transtibial prosthetic socket fit and perhaps find some indication of whether a particular prosthetic socket type might be best for a given situation. In addition, we identified knowledge gaps, thus providing direction for possible future research. We followed the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines, using medical subject headings and standard key words to search for articles in relevant databases. No restrictions were made on study design and type of outcome measure used. From the obtained search results (n = 1,863), 35 articles were included. The relevant data were entered into a predefined data form that included the Downs and Black risk of bias assessment checklist. This article presents the results from the systematic review of the quantitative outcomes (n = 27 articles). Trends indicate that vacuum-assisted suction sockets improve gait symmetry, volume control, and residual limb health more than other socket designs. Hydrostatic sockets seem to create less inconsistent socket fittings, reducing a problem that greatly influences outcome measures. Knowledge gaps exist in the understanding of clinically meaningful changes in socket fit and its effect on biomechanical outcomes. Further, safe and comfortable pressure thresholds under various conditions should be determined through a systematic approach.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schmitz, Roger William; Oh, Yunje
A heating assembly configured for use in mechanical testing at a scale of microns or less. The heating assembly includes a probe tip assembly configured for coupling with a transducer of the mechanical testing system. The probe tip assembly includes a probe tip heater system having a heating element, a probe tip coupled with the probe tip heater system, and a heater socket assembly. The heater socket assembly, in one example, includes a yoke and a heater interface that form a socket within the heater socket assembly. The probe tip heater system, coupled with the probe tip, is slidably receivedmore » and clamped within the socket.« less
SSL: A Theory of How People Learn to Select Strategies
ERIC Educational Resources Information Center
Rieskamp, Jorg; Otto, Philipp E.
2006-01-01
The assumption that people possess a repertoire of strategies to solve the inference problems they face has been raised repeatedly. However, a computational model specifying how people select strategies from their repertoire is still lacking. The proposed strategy selection learning (SSL) theory predicts a strategy selection process on the basis…
A Cluster-then-label Semi-supervised Learning Approach for Pathology Image Classification.
Peikari, Mohammad; Salama, Sherine; Nofech-Mozes, Sharon; Martel, Anne L
2018-05-08
Completely labeled pathology datasets are often challenging and time-consuming to obtain. Semi-supervised learning (SSL) methods are able to learn from fewer labeled data points with the help of a large number of unlabeled data points. In this paper, we investigated the possibility of using clustering analysis to identify the underlying structure of the data space for SSL. A cluster-then-label method was proposed to identify high-density regions in the data space which were then used to help a supervised SVM in finding the decision boundary. We have compared our method with other supervised and semi-supervised state-of-the-art techniques using two different classification tasks applied to breast pathology datasets. We found that compared with other state-of-the-art supervised and semi-supervised methods, our SSL method is able to improve classification performance when a limited number of labeled data instances are made available. We also showed that it is important to examine the underlying distribution of the data space before applying SSL techniques to ensure semi-supervised learning assumptions are not violated by the data.
Orfield, Noah J; Majumder, Somak; McBride, James R; Yik-Ching Koh, Faith; Singh, Ajay; Bouquin, Sarah J; Casson, Joanna L; Johnson, Alex D; Sun, Liuyang; Li, Xiaoqin; Shih, Chih-Kang; Rosenthal, Sandra J; Hollingsworth, Jennifer A; Htoon, Han
2018-05-07
Quantum dots (QDs) are steadily being implemented as down-conversion phosphors in market-ready display products to enhance color rendering, brightness, and energy efficiency. However, for adequate longevity, QDs must be encased in a protective barrier that separates them from ambient oxygen and humidity, and device architectures are designed to avoid significant heating of the QDs as well as direct contact between the QDs and the excitation source. In order to increase the utility of QDs in display technologies and to extend their usefulness to more demanding applications as, for example, alternative phosphors for solid-state lighting (SSL), QDs must retain their photoluminescence emission properties over extended periods of time under conditions of high temperature and high light flux. Doing so would simplify the fabrication costs for QD display technologies and enable QDs to be used as down-conversion materials in light-emitting diodes for SSL, where direct-on-chip configurations expose the emitters to temperatures approaching 100 °C and to photon fluxes from 0.1 W/mm 2 to potentially 10 W/mm 2 . Here, we investigate the photobleaching processes of single QDs exposed to controlled temperature and photon flux. In particular, we investigate two types of room-temperature-stable core/thick-shell QDs, known as "giant" QDs for which shell growth is conducted using either a standard layer-by-layer technique or by a continuous injection method. We determine the mechanistic pathways responsible for thermally-assisted photodegradation, distinguishing effects of hot-carrier trapping and QD charging. The findings presented here will assist in the further development of advanced QD heterostructures for maximum device lifetime stability.
Kuroshima, Shinichiro; Al-Salihi, Zeina; Yamashita, Junro
2013-02-01
The quality and quantity of bone formed in tooth extraction sockets impact implant therapy. Therefore, the establishment of a new approach to enhance bone formation and to minimize bone resorption is important for the success of implant therapy. In this study, we investigated whether intermittent parathyroid hormone (PTH) therapy enhanced bone formation in grafted sockets. Tooth extractions of the maxillary first molars were performed in rats, and the sockets were grafted with xenograft. Intermittent PTH was administered either for 7 days before extractions, for 14 days after extractions, or both. The effect of PTH therapy on bone formation in the grafted sockets was assessed using microcomputed tomography at 14 days after extractions. PTH therapy for 7 days before extractions was not effective to augment bone fill, whereas PTH therapy for 14 days after operation significantly augmented bone formation in the grafted sockets. Intermittent PTH therapy starting right after tooth extractions significantly enhanced bone fill in the grafted sockets, suggesting that PTH therapy can be a strong asset for the success of the ridge preservation procedure.
Instrumented socket inserts for sensing interaction at the limb-socket interface.
Swanson, Eric C; McLean, Jake B; Allyn, Katheryn J; Redd, Christian B; Sanders, Joan E
2018-01-01
The objective of this research was to investigate a strategy for designing and fabricating computer-manufactured socket inserts that were embedded with sensors for field monitoring of limb-socket interactions of prosthetic users. An instrumented insert was fabricated for a single trans-tibial prosthesis user that contained three sensor types (proximity sensor, force sensing resistor, and inductive sensor), and the system was evaluated through a sequence of laboratory clinical tests and two days of field use. During in-lab tests 3 proximity sensors accurately distinguish between don and doff states; 3 of 4 force sensing resistors measured gradual pressure increases as weight-bearing increased; and the inductive sensor indicated that as prosthetic socks were added the limb moved farther out of the socket and pistoning amplitude decreased. Multiple sensor types were necessary in analysis of field collected data to interpret how sock changes affected limb-socket interactions. Instrumented socket inserts, with sensors selected to match clinical questions of interest, have the potential to provide important insights to improve patient care. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
Hauf, Waldemar; Watzer, Björn; Roos, Nora; Klotz, Alexander
2015-01-01
Cyanobacteria are photoautotrophic microorganisms which fix atmospheric carbon dioxide via the Calvin-Benson cycle to produce carbon backbones for primary metabolism. Fixed carbon can also be stored as intracellular glycogen, and in some cyanobacterial species like Synechocystis sp. strain PCC 6803, polyhydroxybutyrate (PHB) accumulates when major nutrients like phosphorus or nitrogen are absent. So far only three enzymes which participate in PHB metabolism have been identified in this organism, namely, PhaA, PhaB, and the heterodimeric PHB synthase PhaEC. In this work, we describe the cyanobacterial PHA surface-coating protein (phasin), which we term PhaP, encoded by ssl2501. Translational fusion of Ssl2501 with enhanced green fluorescent protein (eGFP) showed a clear colocalization to PHB granules. A deletion of ssl2501 reduced the number of PHB granules per cell, whereas the mean PHB granule size increased as expected for a typical phasin. Although deletion of ssl2501 had almost no effect on the amount of PHB, the biosynthetic activity of PHB synthase was negatively affected. Secondary-structure prediction and circular dichroism (CD) spectroscopy of PhaP revealed that the protein consists of two α-helices, both of them associating with PHB granules. Purified PhaP forms oligomeric structures in solution, and both α-helices of PhaP contribute to oligomerization. Together, these results support the idea that Ssl2501 encodes a cyanobacterial phasin, PhaP, which regulates the surface-to-volume ratio of PHB granules. PMID:25911471
Yilmaz, Banu; Aras, Egemen; Nacar, Sinan; Kankal, Murat
2018-05-23
The functional life of a dam is often determined by the rate of sediment delivery to its reservoir. Therefore, an accurate estimate of the sediment load in rivers with dams is essential for designing and predicting a dam's useful lifespan. The most credible method is direct measurements of sediment input, but this can be very costly and it cannot always be implemented at all gauging stations. In this study, we tested various regression models to estimate suspended sediment load (SSL) at two gauging stations on the Çoruh River in Turkey, including artificial bee colony (ABC), teaching-learning-based optimization algorithm (TLBO), and multivariate adaptive regression splines (MARS). These models were also compared with one another and with classical regression analyses (CRA). Streamflow values and previously collected data of SSL were used as model inputs with predicted SSL data as output. Two different training and testing dataset configurations were used to reinforce the model accuracy. For the MARS method, the root mean square error value was found to range between 35% and 39% for the test two gauging stations, which was lower than errors for other models. Error values were even lower (7% to 15%) using another dataset. Our results indicate that simultaneous measurements of streamflow with SSL provide the most effective parameter for obtaining accurate predictive models and that MARS is the most accurate model for predicting SSL. Copyright © 2017 Elsevier B.V. All rights reserved.
Porous Silica-Supported Solid Lipid Particles for Enhanced Solubilization of Poorly Soluble Drugs.
Yasmin, Rokhsana; Rao, Shasha; Bremmell, Kristen E; Prestidge, Clive A
2016-07-01
Low dissolution of drugs in the intestinal fluid can limit their effectiveness in oral therapies. Here, a novel porous silica-supported solid lipid system was developed to optimize the oral delivery of drugs with limited aqueous solubility. Using lovastatin (LOV) as the model poorly water-soluble drug, two porous silica-supported solid lipid systems (SSL-A and SSL-S) were fabricated from solid lipid (glyceryl monostearate, GMS) and nanoporous silica particles Aerosil 380 (silica-A) and Syloid 244FP (silica-S) via immersion/solvent evaporation. SSL particles demonstrated significantly higher rate and extent of lipolysis in comparison with the pure solid lipid, depending on the lipid loading levels and the morphology. The highest lipid digestion was observed when silica-S was loaded with 34% (w/w) solid lipid, and differential scanning calorimeter (DSC) analysis confirmed the encapsulation of up to 2% (w/w) non-crystalline LOV in this optimal SSL-S formulation. Drug dissolution under non-digesting intestinal conditions revealed a three- to sixfold increase in dissolution efficiencies when compared to the unformulated drug and a LOV-lipid suspension. Furthermore, the SSL-S provided superior drug solubilization under simulated intestinal digesting condition in comparison with the drug-lipid suspension and drug-loaded silica. Therefore, solid lipid and nanoporous silica provides a synergistic effect on optimizing the solubilization of poorly water-soluble compound and the solid lipid-based porous carrier system provides a promising delivery approach to overcome the oral delivery challenges of poorly water-soluble drugs.
NASA Astrophysics Data System (ADS)
Tunc, Suleyman; Tunc, Berna; Caka, Deniz; Baris, Serif
2016-04-01
Locating and calculating size of the seismic events is quickly one of the most important and challenging issue in especially real time seismology. In this study, we developed a Matlab application to locate seismic events and calculate their magnitudes (Local Magnitude and empirical Moment Magnitude) using single station called SSL_Calc. This newly developed sSoftware has been tested on the all stations of the Marsite project "New Directions in Seismic Hazard Assessment through Focused Earth Observation in the Marmara Supersite-MARsite". SSL_Calc algorithm is suitable both for velocity and acceleration sensors. Data has to be in GCF (Güralp Compressed Format). Online or offline data can be selected in SCREAM software (belongs to Guralp Systems Limited) and transferred to SSL_Calc. To locate event P and S wave picks have to be marked by using SSL_Calc window manually. During magnitude calculation, instrument correction has been removed and converted to real displacement in millimeter. Then the displacement data is converted to Wood Anderson Seismometer output by using; Z=[0;0]; P=[-6.28+4.71j; -6.28-4.71j]; A0=[2080] parameters. For Local Magnitude calculation,; maximum displacement amplitude (A) and distance (dist) are used in formula (1) for distances up to 200km and formula (2) for more than 200km. ML=log10(A)-(-1.118-0.0647*dist+0.00071*dist2-3.39E-6*dist3+5.71e-9*dist4) (1) ML=log10(A)+(2.1173+0.0082*dist-0.0000059628*dist2) (2) Following Local Magnitude calculation, the programcode calculates two empiric Moment Magnitudes using formulas (3) Akkar et al. (2010) and (4) Ulusay et al. (2004). Mw=0.953* ML+0.422 (3) Mw=0.7768* ML+1.5921 (4) SSL_Calc is a software that is easy to implement and user friendly and offers practical solution to individual users to location of event and ML, Mw calculation.
2014-01-01
Background Besides gene duplication and de novo gene generation, horizontal gene transfer (HGT) is another important way of acquiring new genes. HGT may endow the recipients with novel phenotypic traits that are important for species evolution and adaption to new ecological niches. Parasitic systems expectedly allow the occurrence of HGT at relatively high frequencies due to their long-term physical contact. In plants, a number of HGT events have been reported between the organelles of parasites and the hosts, but HGT between host and parasite nuclear genomes has rarely been found. Results A thorough transcriptome screening revealed that a strictosidine synthase-like (SSL) gene in the root parasitic plant Orobanche aegyptiaca and the shoot parasitic plant Cuscuta australis showed much higher sequence similarities with those in Brassicaceae than with those in their close relatives, suggesting independent gene horizontal transfer events from Brassicaceae to these parasites. These findings were strongly supported by phylogenetic analysis and their identical unique amino acid residues and deletions. Intriguingly, the nucleus-located SSL genes in Brassicaceae belonged to a new member of SSL gene family, which were originated from gene duplication. The presence of introns indicated that the transfer occurred directly by DNA integration in both parasites. Furthermore, positive selection was detected in the foreign SSL gene in O. aegyptiaca but not in C. australis. The expression of the foreign SSL genes in these two parasitic plants was detected in multiple development stages and tissues, and the foreign SSL gene was induced after wounding treatment in C. australis stems. These data imply that the foreign genes may still retain certain functions in the recipient species. Conclusions Our study strongly supports that parasitic plants can gain novel nuclear genes from distantly related host species by HGT and the foreign genes may execute certain functions in the new hosts. PMID:24411025
Zhang, Dale; Qi, Jinfeng; Yue, Jipei; Huang, Jinling; Sun, Ting; Li, Suoping; Wen, Jian-Fan; Hettenhausen, Christian; Wu, Jinsong; Wang, Lei; Zhuang, Huifu; Wu, Jianqiang; Sun, Guiling
2014-01-13
Besides gene duplication and de novo gene generation, horizontal gene transfer (HGT) is another important way of acquiring new genes. HGT may endow the recipients with novel phenotypic traits that are important for species evolution and adaption to new ecological niches. Parasitic systems expectedly allow the occurrence of HGT at relatively high frequencies due to their long-term physical contact. In plants, a number of HGT events have been reported between the organelles of parasites and the hosts, but HGT between host and parasite nuclear genomes has rarely been found. A thorough transcriptome screening revealed that a strictosidine synthase-like (SSL) gene in the root parasitic plant Orobanche aegyptiaca and the shoot parasitic plant Cuscuta australis showed much higher sequence similarities with those in Brassicaceae than with those in their close relatives, suggesting independent gene horizontal transfer events from Brassicaceae to these parasites. These findings were strongly supported by phylogenetic analysis and their identical unique amino acid residues and deletions. Intriguingly, the nucleus-located SSL genes in Brassicaceae belonged to a new member of SSL gene family, which were originated from gene duplication. The presence of introns indicated that the transfer occurred directly by DNA integration in both parasites. Furthermore, positive selection was detected in the foreign SSL gene in O. aegyptiaca but not in C. australis. The expression of the foreign SSL genes in these two parasitic plants was detected in multiple development stages and tissues, and the foreign SSL gene was induced after wounding treatment in C. australis stems. These data imply that the foreign genes may still retain certain functions in the recipient species. Our study strongly supports that parasitic plants can gain novel nuclear genes from distantly related host species by HGT and the foreign genes may execute certain functions in the new hosts.
Semi-Supervised Learning of Lift Optimization of Multi-Element Three-Segment Variable Camber Airfoil
NASA Technical Reports Server (NTRS)
Kaul, Upender K.; Nguyen, Nhan T.
2017-01-01
This chapter describes a new intelligent platform for learning optimal designs of morphing wings based on Variable Camber Continuous Trailing Edge Flaps (VCCTEF) in conjunction with a leading edge flap called the Variable Camber Krueger (VCK). The new platform consists of a Computational Fluid Dynamics (CFD) methodology coupled with a semi-supervised learning methodology. The CFD component of the intelligent platform comprises of a full Navier-Stokes solution capability (NASA OVERFLOW solver with Spalart-Allmaras turbulence model) that computes flow over a tri-element inboard NASA Generic Transport Model (GTM) wing section. Various VCCTEF/VCK settings and configurations were considered to explore optimal design for high-lift flight during take-off and landing. To determine globally optimal design of such a system, an extremely large set of CFD simulations is needed. This is not feasible to achieve in practice. To alleviate this problem, a recourse was taken to a semi-supervised learning (SSL) methodology, which is based on manifold regularization techniques. A reasonable space of CFD solutions was populated and then the SSL methodology was used to fit this manifold in its entirety, including the gaps in the manifold where there were no CFD solutions available. The SSL methodology in conjunction with an elastodynamic solver (FiDDLE) was demonstrated in an earlier study involving structural health monitoring. These CFD-SSL methodologies define the new intelligent platform that forms the basis for our search for optimal design of wings. Although the present platform can be used in various other design and operational problems in engineering, this chapter focuses on the high-lift study of the VCK-VCCTEF system. Top few candidate design configurations were identified by solving the CFD problem in a small subset of the design space. The SSL component was trained on the design space, and was then used in a predictive mode to populate a selected set of test points outside of the given design space. The new design test space thus populated was evaluated by using the CFD component by determining the error between the SSL predictions and the true (CFD) solutions, which was found to be small. This demonstrates the proposed CFD-SSL methodologies for isolating the best design of the VCK-VCCTEF system, and it holds promise for quantitatively identifying best designs of flight systems, in general.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gaponov, Yu.A.; Igarashi, N.; Hiraki, M.
2004-05-12
An integrated controlling system and a unified database for high throughput protein crystallography experiments have been developed. Main features of protein crystallography experiments (purification, crystallization, crystal harvesting, data collection, data processing) were integrated into the software under development. All information necessary to perform protein crystallography experiments is stored (except raw X-ray data that are stored in a central data server) in a MySQL relational database. The database contains four mutually linked hierarchical trees describing protein crystals, data collection of protein crystal and experimental data processing. A database editor was designed and developed. The editor supports basic database functions to view,more » create, modify and delete user records in the database. Two search engines were realized: direct search of necessary information in the database and object oriented search. The system is based on TCP/IP secure UNIX sockets with four predefined sending and receiving behaviors, which support communications between all connected servers and clients with remote control functions (creating and modifying data for experimental conditions, data acquisition, viewing experimental data, and performing data processing). Two secure login schemes were designed and developed: a direct method (using the developed Linux clients with secure connection) and an indirect method (using the secure SSL connection using secure X11 support from any operating system with X-terminal and SSH support). A part of the system has been implemented on a new MAD beam line, NW12, at the Photon Factory Advanced Ring for general user experiments.« less
Osaki, Kanji; Okazaki, Ken; Matsubara, Hirokazu; Kuwashima, Umito; Murakami, Koji; Iwamoto, Yukihide
2015-12-01
To investigate the mismatch between the length at the center and the length on the shortest and longest peripheral sides of the femoral tunnel socket, reamed with the transportal (TP), outside-in (OI), and modified transtibial (TT) techniques, in anterior cruciate ligament (ACL) reconstruction. Femoral tunnel drilling was simulated on 3-dimensional bone models from 40 subjects. The tunnel directions used with the TP, OI, and modified TT techniques were previously described. By use of the resulting angle, a femoral tunnel socket of 9 mm in diameter was drilled from the center of the femoral ACL insertion. The virtual femoral tunnel was extracted, and the length mismatch was measured between the center and the shortest and longest peripheral sides of the tunnel socket. The mean socket length mismatch between the center and the shortest peripheral part of the femoral tunnel socket was 4.2 ± 0.9 mm with the TP technique, 5.2 ± 1.3 mm with the OI technique, and 3.2 ± 0.8 mm with the modified TT technique. The mean socket length mismatch between the center and the longest peripheral part of the femoral tunnel socket was 3.5 ± 0.9 mm with the TP technique, 4.8 ± 1.5 mm with the OI technique, and 3.3 ± 1.2 mm with the modified TT technique. The length mismatch was significantly higher when the tunnel socket was created by the OI technique (P < .01). A length mismatch with the tunnel socket exists after reaming with either the TP, OI, or modified TT technique. In particular, there was a significant increase in length mismatch when the tunnel socket was created by the OI technique, and the length mismatch would easily become greater than 5 mm. The surgeon should recognize this mismatch when it is created and measure the femoral tunnel socket. In anatomic ACL reconstruction, a mismatch between the length at the center and the length at periphery of the femoral tunnel socket occurs, and this is increased particularly when using the OI technique. The discrepancy in tunnel length between its center and its periphery could cause an overestimation of the tunnel length that could result in an error in length during graft preparation. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Leonida, Alessandro; Todeschini, Giovanni; Lomartire, Giovanni; Cinci, Lorenzo; Pieri, Laura
2016-11-01
To histologically assess the effectiveness of a socket-preservation technique using enzyme-treated equine bone granules as a bone-graft material in combination with an equine collagen matrix as a scaffold for soft-tissue regeneration. Enzyme-treated equine bone granules and equine collagen matrix recently have been developed to help overcome alveolar bone deficiencies that develop in the wake of edentulism. The patient had one mandibular molar extracted and the socket grafted with equine bone granules. The graft was covered with the equine collagen matrix, placed in a double layer. No flap was prepared, and the gingival margins were stabilized with a single stitch, leaving the matrix partially exposed and the site to heal by secondary intention. The adjacent molar was extracted 1 month later, and that socket was left to heal by secondary intention without any further treatment. Three months after each surgery, an implant was placed and a biopsy was collected. The two biopsies underwent histological processing and qualitative evaluation. Histomorphometric analysis was also performed to calculate the percentage of newly formed bone (NFB) in the two cores. Healing at both sites was uneventful, and no inflammation or other adverse reactions were observed in the samples. Soft-tissue healing by secondary intention appeared to occur faster at the grafted site. The corresponding core showed a marked separation between soft and hard tissue that was not observed in the core from the nongrafted site, where soft-tissue hypertrophy could be observed. Newly formed bone at the grafted and nongrafted sites was not significantly different (27.2 ± 7.1 and 29.4 ± 6.2% respectively, p = 0.45). The surgical technique employed in this case appeared to facilitate postextraction soft-tissue healing by second intention and simplify soft-tissue management. Using a collagen-based matrix to cover a postextraction grafted site may facilitate second intention soft-tissue healing and proper soft-tissue growth.
Kim, Jung-Ju; Song, Hyun Young; Ben Amara, Heithem; Kyung-Rim, Kang; Koo, Ki-Tae
2016-07-01
Previous studies on ridge preservation focusing on fresh extraction sockets using graft materials for ridge preservation procedures have reported a delay in the tissue modeling and remodeling phases. The objective of this study is to evaluate the effect of hyaluronic acid (HA) on healing of infected sockets. Six beagle dogs were used in this study. Both mandibular third premolars were hemisected, and the distal roots were extracted. Subsequently, periodontal and endodontic lesions were induced at the remaining mesial root. After communication of the periodontal lesion, an endodontic periapical lesion was observed at 4 months, and the mesial roots of both the right and left sides were extracted. HA was applied into the socket of the test group, and no treatment was administered to the other group (control group). Three months after extraction of the mesial roots, the dogs were sacrificed, and histologic evaluations were performed. The sockets were filled by mineralized bone (47.80% ± 6.60%) and bone marrow (50.47% ± 6.38%) in the control group, whereas corresponding values were 63.29% ± 9.78% and 34.73% ± 8.97% for the test group, respectively. There was a statistically significant difference between the groups. Reversal lines and a copious lineup of osteoblasts were observed in the middle and apical parts of the sockets in the test group. An infected socket shows delayed healing of the socket wound, and HA, because of its osteoinductive, bacteriostatic, and anti-inflammatory properties, may improve bone formation and accelerate wound healing in infected sockets.
Nasser, Qasiem J.; Gombos, Dan S.; Williams, Michelle D.; Guadagnolo, B. Ashleigh; Morrison, William H.; Garden, Adam S.; Beadle, Beth M.; Canseco, Elvia; Esmaeli, Bita
2012-01-01
Purpose High-dose radiotherapy can cause contracture of the anophthalmic socket, but the incidence of this complication in patients with enucleation for uveal melanoma has not previously been reported. We reviewed the surgical management and outcomes in terms of successful prosthesis wear in patients with severe contracture of the anophthalmic socket treated with high-dose radiotherapy for high-risk uveal melanoma and estimated the relative risk of this complication. Methods The medical records of all consecutive patients enrolled in a prospective uveal-melanoma tissue-banking protocol at our institution who underwent enucleation between January 2003 and December 2010 were reviewed. Patients who underwent adjuvant radiotherapy of the enucleated socket were further studied. Results Of the 68 patients enrolled in the prospective tissue banking protocol, 12 had high-risk histologic features (e.g., extrascleral spread or vortex vein invasion) and were treated with 60 Gy of external-beam radiotherapy after enucleation. Five of these patients (41.7%) experienced severe socket contracture precluding prosthesis wear. The median time to onset of contracture following completion of radiotherapy was 20 months. Three patients underwent surgery, which entailed scar tissue release, oral mucous membrane grafting, and socket reconstruction; 2 patients declined surgery. All 3 patients who had surgery experienced significant improvement of socket contracture that enabled patients to wear a prosthesis again. Conclusion High-dose radiotherapy after enucleation in patients with uveal melanoma caused severe socket contracture and inability to wear a prosthesis in approximately 40% of patients. Surgical repair of the contracted socket using oral mucous membrane grafting can allow resumption of prosthesis wear. PMID:22581085
Prosthetic limb sockets from plant-based composite materials.
Campbell, Andrew I; Sexton, Sandra; Schaschke, Carl J; Kinsman, Harry; McLaughlin, Brian; Boyle, Martin
2012-06-01
There is a considerable demand for lower limb prostheses globally due to vascular disease, war, conflict, land mines and natural disasters. Conventional composite materials used for prosthetic limb sockets include acrylic resins, glass and carbon fibres, which produce harmful gasses and dust in their manufacture. To investigate the feasibility of using a renewable plant oil-based polycarbonate-polyurethane copolymer resin and plant fibre composite, instead of conventional materials, to improve safety and accessibility of prosthetic limb manufacture. Experimental, bench research. Test pieces of the resin with a range of plant fibres (10.0% by volume) were prepared and tensile strengths were tested. Test sockets of both conventional composite materials and plant resin with plant fibres were constructed and tested to destruction. Combinations of plant resin and either banana or ramie fibres gave high tensile strengths. The conventional composite material socket and plant resin with ramie composite socket failed at a similar loading, exceeding the ISO 10328 standard. Both wall thickness and fibre-matrix adhesion played a significant role in socket strength. From this limited study we conclude that the plant resin and ramie fibre composite socket has the potential to replace the standard layup. Further mechanical and biocompatibility testing as well as a full economic analysis is required. Using readily sourced and renewable natural fibres and a low-volatile bio-resin has potential to reduce harm to those involved in the manufacture of artificial limb sockets, without compromising socket strength and benefitting clinicians working in poorer countries where safety equipment is scarce. Such composite materials will reduce environmental impact.
Hattingh, André C; De Bruyn, Hugo; Ackermann, Andrew; Vandeweghe, Stefan
Immediate implant placement is performed less frequently in molar extraction sockets than in single root sockets. This is mainly due to the tripodal anatomical configuration of molar roots, which is perceived as complex and therefore unsuitable. The mechanical burden of molar sites, combined with much larger socket dimensions, make it amenable to the use of ultrawide-diameter dental implants. This article describes a practical, sequenced technique that can be used predictably for immediate implant placement in maxillary and mandibular first molar sockets, using a dry skull model for clarification. This detailed description is based on the experience of more than 580 clinical cases over a 10-year period.
Reusable vibration resistant integrated circuit mounting socket
Evans, Craig N.
1995-01-01
This invention discloses a novel form of socket for integrated circuits to be mounted on printed circuit boards. The socket uses a novel contact which is fabricated out of a bimetallic strip with a shape which makes the end of the strip move laterally as temperature changes. The end of the strip forms a barb which digs into an integrated circuit lead at normal temperatures and holds it firmly in the contact, preventing loosening and open circuits from vibration. By cooling the contact containing the bimetallic strip the barb end can be made to release so that the integrated circuit lead can be removed from the socket without damage either to the lead or to the socket components.
Tolstunov, L
2012-12-01
The aim of this prospective comparative split-mouth study was to evaluate the role of socket irrigation with a normal saline solution routinely used at the end of extraction on the development of alveolar osteitis (AO) after removal of impacted mandibular third molars (MTMs). Thirty-five patients who satisfied the inclusion criteria were involved in the study and underwent extraction of four third-molars. To be included in the study, the mandibular third molars had to be impacted (partial or full bone) and require an osteotomy for extraction with use of a motorised drill. All surgeries were done under local anaesthesia or IV sedation. This was a prospective split-mouth study. The patient's left (assistant) side was a control side; it had a standard extraction technique of an impacted mandibular third molar that required a buccal full-thickness flap, buccal trough (osteotomy) and extraction of the tooth (with or without splitting the tooth into segments), followed by a traditional end-of-surgery debridement protocol consisting of a gentle curettage, bone filing of the socket walls, socket irrigation with approximately 5 ml of sterile normal saline solution and socket suctioning. The patient's right (operator) side was an experimental side; it also had a standard extraction technique of an impacted mandibular third molar at the beginning with a flap and osteotomy, but it was followed by a modified end-of-surgery protocol. It consisted of gentle curettage but the socket was not irrigated and not suctioned. It was simply left to bleed. The gauze was placed on top of the socket for haemostasis on both sides and the patient was asked to bite. On both sides, the buccal flap was positioned back without the suture. All patients were seen for a follow-up appointment four to seven days after the surgery to assess healing and check for symptoms and signs of alveolar osteitis, if present, on both irrigated and non-irrigated sides. This study followed the ethical guidelines of human subjects based on the Helsinki Declaration. Thirty-five patients or 70 sockets were evaluated. Eleven out of 35 patients in the study were subjected to a dry socket syndrome (31.4%). The higher number of AO was likely related to specifics of MTM selection in this study - only impacted (partial and full bone) MTMs were chosen. Among eleven patients with AO, two patients had a bilateral condition. By excluding two patients with bilateral dry sockets from the study, there were nine patients (18 extraction sites) with unilateral AO in the study. Seven out of nine patients (14 extraction sites) developed unilateral dry socket on the control (irrigated) side (77.8%) and only two (four extraction sites) on the experimental (non-irrigated) side (22.2%). Therefore, in this study there were 3.5 times more patients (extraction sites) with dry socket syndrome on the irrigated (control) side than patients (extraction sites) in the non-irrigated (experimental) side. A noticeable difference of dry socket syndromes (77.8% on the irrigated versus 22.2% on non-irrigated side) was demonstrated between the traditional extraction protocol versus modified approach without the end-of-surgery irrigation. The study demonstrated that the post-extraction socket bleeding is very important for the proper uncomplicated socket healing. If it's not washed away with irrigation solution at the end of extraction, the normal blood clot has a higher likelihood to form, and therefore, can potentially lead to an uncomplicated socket healing without development of alveolar osteitis. Socket bleeding at the extraction site creates a favourable environment for the formation of a blood clot - a protective dressing - necessary for a favourable osseous healing of the socket.
Antetomaso, Jordan; Kumar, Satish
2018-03-01
Immediate implant placement into fresh extraction sockets versus delayed implants into healed sockets: a systematic review and meta-analysis. Mello CC, Lemos CAA, Verri FR, Dos Santos DM, Goiato MC, Pellizzer EP. Int J Oral Maxillofac Surg 2017; 46(9):1162-77. None TYPE OF STUDY/DESIGN: Systematic review with meta-analysis of data. Copyright © 2017 Elsevier Inc. All rights reserved.
Nayak, Chitresh; Singh, Amit; Chaudhary, Himanshu; Unune, Deepak Rajendra
2017-10-23
Technological advances in prosthetics have attracted the curiosity of researchers in monitoring design and developments of the sockets to sustain maximum pressure without any soft tissue damage, skin breakdown, and painful sores. Numerous studies have been reported in the area of pressure measurement at the limb/socket interface, though, the relation between amputee's physiological parameters and the pressure developed at the limb/socket interface is still not studied. Therefore, the purpose of this work is to investigate the effects of patient-specific physiological parameters viz. height, weight, and stump length on the pressure development at the transtibial prosthetic limb/socket interface. Initially, the pressure values at the limb/socket interface were clinically measured during stance and walking conditions for different patients using strain gauges placed at critical locations of the stump. The measured maximum pressure data related to patient's physiological parameters was used to develop an artificial neural network (ANN) model. The effects of physiological parameters on the pressure development at the limb/socket interface were examined using the ANN model. The analyzed results indicated that the weight and stump length significantly affects the maximum pressure values. The outcomes of this work could be an important platform for the design and development of patient-specific prosthetic socket which can endure the maximum pressure conditions at stance and ambulation conditions.
Improving socket design to prevent difficult removal of locking screws.
Lin, Chen-Huei; Chao, Ching-Kong; Tang, Yi-Hsuan; Lin, Jinn
2018-03-01
Reports of driver slippage leading to difficult locking screw removals have increased since the adoption of titanium for screw fabrication; the use of titanium is known to cause cross-threading and cold welding. Such problems occur most frequently in screws with hex sockets, and may cause serious surgical complications. This study aimed to improve screw socket design to prevent slippage and difficult screw removal. Three types of small sockets (hex, Torx, and cruciate) and six types of large sockets (hex, Torx, Octatorx, Torx+ I, Torx+ II, and Torx+ III) with screw head diameters of 5.5 mm were manufactured from titanium, and corresponding screwdrivers were manufactured from stainless steel. The screw heads and drivers were mounted on a material testing machine, and torsional tests were conducted to simulate screw usage in clinical settings at two insertion depths: 1 and 2 mm. Ten specimens were tested from each design, and the maximum torque and failure patterns were recorded and compared. For small sockets in 2 mm conditions, the hex with the largest driver core had the highest torque, followed by Torx and cruciate. In these tests, the drivers were twisted off in all specimens. However, under the 1 mm condition, the hex slipped and the torque decreased markedly. Overall, torque was higher for large sockets than for small sockets. The Octatorx, with a large core and simultaneous deformation of the driver and socket lobes, had the highest torque at almost twice that of the small hex. The hex had the lowest torque, a result of slippage in both the 1 and 2 mm conditions. Torx plus designs, with more designed degrees of freedom, were able to maintain a higher driving angle and larger core for higher torque. The hex design showed slipping tendencies with a marked decrease in torque, especially under conditions with inadequate driver engagement. Large sockets allowed for substantial increases in torque. The Torx, Octatorx, and Torx plus designs displayed better performance than the hexes. Improvements to the socket design could effectively prevent slippage and solve difficult screw removal problems. Copyright © 2018. Published by Elsevier Ltd.
Möbius, R; Schleifenbaum, S; Grunert, R; Löffler, S; Werner, M; Prietzel, T; Hammer, N
2016-10-01
The removal of well-fixed acetabular components following THA (total hip arthroplasty) is a difficult operation and could be accompanied by the loss of acetabular bone stock. The optimal method for fixation is still under debate. The aim of this pilot study was to compare the tear-out resistance and failure behavior between osseo-integrated and non-integrated screw cups. Furthermore, we examined whether there are differences in the properties mentioned between screw sockets and cemented polyethylene cups. Tear-out resistance and related mechanical work required for the tear-out of osseo-integrated screw sockets are higher than in non-integrated screw sockets. Ten human coxal bones from six cadavers with osseo-integrated screw sockets (n=4), non-integrated (implanted post-mortem, n=3) screw sockets and cemented polyethylene cups (n=3) were used for tear-out testing. The parameters axial failure load and mechanical work for tear-out were introduced as measures for determining the stability of acetabular components following THA. The osseo-integrated screw sockets yielded slightly higher tear-out resistance (1.61±0.26kN) and related mechanical work compared to the non-integrated screw sockets (1.23±0.39kN, P=0.4). The cemented polyethylene cups yielded the lowest tear-out resistance with a failure load of 1.18±0.24kN. Compared to the screw cups implanted while alive, they also differ on a non-significant level (P=0.1). Osseous failure patterns differed especially for the screw sockets compared to the cemented polyethylene cups. Osseo-integration did not greatly influence the tear-out stability in cementless screw sockets following axial loading. Furthermore, the strength of the bone-implant-interface of cementless screw sockets appears to be similar to cemented polyethylene cups. However, given the high failure load, high mechanical load and because of the related bone failure patterns, removal should not be performed by means of tear-out but rather by osteotomes or other curved cutting devices to preserve the acetabular bone stock. Level III, case-control-study. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
29 CFR 1926.1414 - Wire rope-selection and installation criteria.
Code of Federal Regulations, 2014 CFR
2014-07-01
... sockets must be attached to the unloaded dead end of the rope only, except that the use of devices specifically designed for dead-ending rope in a wedge socket is permitted. (g) Socketing must be done in the...
29 CFR 1926.1414 - Wire rope-selection and installation criteria.
Code of Federal Regulations, 2012 CFR
2012-07-01
... sockets must be attached to the unloaded dead end of the rope only, except that the use of devices specifically designed for dead-ending rope in a wedge socket is permitted. (g) Socketing must be done in the...
29 CFR 1926.1414 - Wire rope-selection and installation criteria.
Code of Federal Regulations, 2013 CFR
2013-07-01
... sockets must be attached to the unloaded dead end of the rope only, except that the use of devices specifically designed for dead-ending rope in a wedge socket is permitted. (g) Socketing must be done in the...
Hasheminia, Dariush; Moaddabi, Amirhossein; Moradi, Saeid; Soltani, Parisa; Moannaei, Mahsa; Issazadeh, Maryam
2018-05-01
Dry socket or alveolar osteitis is a delayed healing of alveolar bone after exodontia causing moderate to severe pain 2-4 days after extraction of teeth. Antibacterial agents such as antibiotics and chlorhexidine have been previously proved to prevent or reduce the incidence of dry socket. Betadine is a mixture of iodine and povidone which has bactericidal, antifungal and antiviral effects. The aim of the present study was to evaluate the effect of preoperative povidone iodine 1% mouthwash before surgical extraction of impacted mandibular third molar, however age, gender and oral hygiene were also considered. 189 patients who needed surgical extraction of Pell and Gregory class A and B mandibular third molars were included in this study. The patients who were not willing to participate in the study, took, women who took oral contraceptives or were in the first 22 days of menstrual cycle were excluded. Patients were randomly assigned to control or test group. 97 patients in the test group took preoperative povidone iodine 1% mouthwash and 92 patients in the control group didn't take any antibiotic or mouthwash. Patients were examined in days 3 and 7 postoperatively for incidence of alveolar osteitis. Chi-square test didn't show any significant relation between dry socket incidence and gender ( p value: 0.848) and Oral hygiene ( p value: 0.866). However, it revealed a significant relation between age and dry socket incidence ( p value: 0.003) and patients older than 30 were reported to have higher incidence of dry socket. Independent T-Test showed a significant difference between the test and control group in incidence of dry socket ( p value: 0.036). Based on the results of this study povidone iodine 1% mouthwash can decrease dry socket incidence also as the age increases, the incidence of dry socket becomes higher. Key words: Dry socket, impaction, betadine, povidone iodine.
Hasheminia, Dariush; Moaddabi, Amirhossein; Moradi, Saeid; Moannaei, Mahsa; Issazadeh, Maryam
2018-01-01
Background Dry socket or alveolar osteitis is a delayed healing of alveolar bone after exodontia causing moderate to severe pain 2-4 days after extraction of teeth. Antibacterial agents such as antibiotics and chlorhexidine have been previously proved to prevent or reduce the incidence of dry socket. Betadine is a mixture of iodine and povidone which has bactericidal, antifungal and antiviral effects. The aim of the present study was to evaluate the effect of preoperative povidone iodine 1% mouthwash before surgical extraction of impacted mandibular third molar, however age, gender and oral hygiene were also considered. Material and Methods 189 patients who needed surgical extraction of Pell and Gregory class A and B mandibular third molars were included in this study. The patients who were not willing to participate in the study, took, women who took oral contraceptives or were in the first 22 days of menstrual cycle were excluded. Patients were randomly assigned to control or test group. 97 patients in the test group took preoperative povidone iodine 1% mouthwash and 92 patients in the control group didn’t take any antibiotic or mouthwash. Patients were examined in days 3 and 7 postoperatively for incidence of alveolar osteitis. Results Chi-square test didn’t show any significant relation between dry socket incidence and gender (p value: 0.848) and Oral hygiene (p value: 0.866). However, it revealed a significant relation between age and dry socket incidence (p value: 0.003) and patients older than 30 were reported to have higher incidence of dry socket. Independent T-Test showed a significant difference between the test and control group in incidence of dry socket (p value: 0.036). Conclusions Based on the results of this study povidone iodine 1% mouthwash can decrease dry socket incidence also as the age increases, the incidence of dry socket becomes higher. Key words:Dry socket, impaction, betadine, povidone iodine. PMID:29849968
Systemic review of dry socket: aetiology, treatment, and prevention.
Tarakji, Bassel; Saleh, Lubna Ahmed; Umair, Ayesha; Azzeghaiby, Saleh Nasser; Hanouneh, Salah
2015-04-01
Our systemic review is to make a comprehensive review about the aetiology, treatment and the prevention of dry socket, the inclusion criteria were all the studies that discuss the dry socket and its etiology, treatment and prevention and exclusion criteria were all the studies that discuss the other complications of tooth extraction, the materials and methods used for this systemic review was to search in the Pub Medline database between 2008 to 2013, using specific words "dry socket, aetiology, treatment and prevention" and published in the English language, the articles were screened by abstract for relevance to aetiology, treatment and prevention of dry socket, 82 papers were identified in pub med but a total of 36 out of Publications were included in the final systemic review according to the specific keywords and materials mentioned above. The occurrence of dry socket in an everyday oral surgery or dental practice is unavoidable. The risk factors are smoking, surgical trauma, single extractions, age, sex, medical history, systemic disorder, extraction site, amount of anaesthesia, operator experience, antibiotics use prior to surgery, difficulty of the surgery and the previous surgical site infection in addition to oral Contraceptives, menstrual cycle and immediate postextraction socket irrigation with normal saline. The traditional options of treatment are directed toward palliative care, such as the irrigation of the surgical site, avoiding curetting the extraction socket, Packing with a zinc oxide- eugenol paste on iodoform gauze can be considered to relieve acute pain episodes, there is also new agents in the market can accelerate the healing of the socket such as PRGF and GECB. The prevention methods include avoiding smoking before and after surgery and a traumatic surgery, the use of antibiotics, such as, azithromycin, can be considered, the other preventive measures such as chlorhecidine rinse or gel can be effective in the reduction of dry socket incidence.
Systemic Review of Dry Socket: Aetiology, Treatment, and Prevention
Saleh, Lubna Ahmed; Umair, Ayesha; Azzeghaiby, Saleh Nasser; Hanouneh, Salah
2015-01-01
Our systemic review is to make a comprehensive review about the aetiology, treatment and the prevention of dry socket, the inclusion criteria were all the studies that discuss the dry socket and its etiology, treatment and prevention and exclusion criteria were all the studies that discuss the other complications of tooth extraction, the materials and methods used for this systemic review was to search in the Pub Medline database between 2008 to 2013, using specific words “dry socket, aetiology, treatment and prevention” and published in the English language, the articles were screened by abstract for relevance to aetiology, treatment and prevention of dry socket, 82 papers were identified in pub med but a total of 36 out of Publications were included in the final systemic review according to the specific keywords and materials mentioned above. The occurrence of dry socket in an everyday oral surgery or dental practice is unavoidable. The risk factors are smoking, surgical trauma, single extractions, age, sex, medical history, systemic disorder, extraction site, amount of anaesthesia, operator experience, antibiotics use prior to surgery, difficulty of the surgery and the previous surgical site infection in addition to oral Contraceptives, menstrual cycle and immediate postextraction socket irrigation with normal saline. The traditional options of treatment are directed toward palliative care, such as the irrigation of the surgical site, avoiding curetting the extraction socket, Packing with a zinc oxide– eugenol paste on iodoform gauze can be considered to relieve acute pain episodes, there is also new agents in the market can accelerate the healing of the socket such as PRGF and GECB. The prevention methods include avoiding smoking before and after surgery and a traumatic surgery, the use of antibiotics, such as, azithromycin, can be considered, the other preventive measures such as chlorhecidine rinse or gel can be effective in the reduction of dry socket incidence. PMID:26023661
An assessment technique for computer-socket manufacturing
Sanders, Joan; Severance, Michael
2015-01-01
An assessment strategy is presented for testing the quality of carving and forming of individual computer aided manufacturing facilities. The strategy is potentially useful to facilities making sockets and companies marketing manufacturing equipment. To execute the strategy, an evaluator fabricates a collection of test models and sockets using the manufacturing suite under evaluation, and then measures their shapes using scanning equipment. Overall socket quality is assessed by comparing socket shapes with electronic file shapes. Then model shapes are compared with electronic file shapes to characterize carving performance. Socket shapes are compared with model shapes to characterize forming performance. The mean radial error (MRE), which is the average difference in radii between the two shapes being compared, provides insight into sizing quality. Inter-quartile range (IQR), the range of radial error for the best matched half of the points on the surfaces being compared, provides insight into shape quality. By determining MRE and IQR for carving and forming separately, the source(s) of socket shape error may be pinpointed. The developed strategy may provide a useful tool to the prosthetics community and industry to help identify problems and limitations in computer aided manufacturing and insight into appropriate modifications to overcome them. PMID:21938663
HOW DOES ADDING AND REMOVING LIQUID FROM SOCKET BLADDERS AFFECT RESIDUAL LIMB FLUID VOLUME?
Sanders, JE; Cagle, JC; Harrison, DS; Myers, TR; Allyn, KJ
2015-01-01
Adding and removing liquid from socket bladders is a means for people with limb loss to accommodate residual limb volume change. Nineteen people with trans-tibial amputation using their regular prosthetic socket fitted with fluid bladders on the inside socket surface underwent cycles of bladder liquid addition and removal. In each cycle, subjects sat, stood, and walked for 90s with bladder liquid added and then sat, stood, and walking for 90s again with the bladder liquid removed. The amount of bladder liquid added was increased in each cycle. Bioimpedance analysis was implemented to measure residual limb fluid volume. Results showed that the preferred bladder liquid volume was 16.8 mL (s.d.8.4), corresponding to 1.7% (s.d.0.8%) of the average socket volume between the bioimpedance voltage-sensing electrodes. Limb fluid volume driven out of the residual limb when bladder liquid was added was typically not recovered upon subsequent bladder liquid removal. Fifteen of nineteen subjects experienced a gradual limb fluid volume loss over the test session. Care should be taken when implementing adjustable socket technologies in people with limb amputation. Reducing socket volume may accentuate limb fluid volume loss. PMID:24203546
Biswas, Sondip K; Lee, Jai Eun; Brako, Lawrence; Jiang, Jean X; Lo, Woo-Kuen
2010-11-09
Ball-and-sockets and protrusions are specialized interlocking membrane domains between lens fibers of all species studied. Ball-and-sockets and protrusions are similar in their shape, size, and surface morphology, and are traditionally believed to play a key role in maintaining fiber-to-fiber stability. Here, we evaluate the hypothesis that ball-and-sockets and protrusions possess important structural and functional differences during fiber cell differentiation and maturation. Intact lenses of leghorn chickens (E7 days to P62 weeks old) and rhesus monkeys (1.5-20 years old) were studied with SEM, freeze-fracture TEM, freeze-fracture immunogold labeling (FRIL), and filipin cytochemistry for membrane cholesterol detection. SEM showed that ball-and-sockets were distributed along the long and short sides of hexagonal fiber cells, whereas protrusions were located along the cell corners, from superficial to deep cortical regions in both chicken and monkey lenses. Importantly, by freeze-fracture TEM, we discovered the selective association of gap junctions with all ball-and-sockets examined, but not with protrusions, in both species. In the embryonic chicken lens (E18), the abundant distribution of ball-and-socket gap junctions was regularly found in an approximate zone extending at least 300 μm deep from the equatorial surface of the superficial cortical fibers. Many ball-and-socket gap junctions often protruded deeply into neighboring cells. However, in the mature fibers of monkey lenses, several ball-and-sockets exhibited only partial occupancy of gap junctions with disorganized connexons, possibly due to degradation of gap junctions during fiber maturation and aging. FRIL analysis confirmed that both connexin46 (Cx46) and connexin50 (Cx50) antibodies specifically labeled ball-and-socket gap junctions, but not protrusions. Furthermore, filipin cytochemistry revealed that the ball-and-socket gap junctions contained different amounts of cholesterol (i.e., cholesterol-rich versus cholesterol-free) as seen with the filipin-cholesterol-complexes (FCC) in different cortical regions during maturation. In contrast, the protrusions contained consistently high cholesterol amounts (i.e., 402 FCCs/μm2 membrane) which were approximately two times greater than that of the cholesterol-rich gap junctions (i.e., 188 FCCs/μm2 membrane) found in ball-and-sockets. Gap junctions are regularly associated with all ball-and-sockets examined in metabolically active young cortical fibers, but not with protrusions, in both chicken and monkey lenses. Since these unique gap junctions often protrude deeply into neighboring cells to increase membrane surface areas, they may significantly facilitate cell-to-cell communication between young cortical fiber cells. In particular, the large number of ball-and-socket gap junctions found near the equatorial region may effectively facilitate the flow of outward current toward the equatorial surface for internal circulation of ions in the lens. In contrast, a consistent distribution of high concentrations of cholesterol in protrusions would make the protrusion membrane less deformable and would be more suitable for maintaining fiber-to-fiber stability during visual accommodation. Thus, the ball-and-sockets and protrusions are two structurally and functionally distinct membrane domains in the lens.
Biswas, Sondip K.; Lee, Jai Eun; Brako, Lawrence; Jiang, Jean X.
2010-01-01
Purpose Ball-and-sockets and protrusions are specialized interlocking membrane domains between lens fibers of all species studied. Ball-and-sockets and protrusions are similar in their shape, size, and surface morphology, and are traditionally believed to play a key role in maintaining fiber-to-fiber stability. Here, we evaluate the hypothesis that ball-and-sockets and protrusions possess important structural and functional differences during fiber cell differentiation and maturation. Methods Intact lenses of leghorn chickens (E7 days to P62 weeks old) and rhesus monkeys (1.5–20 years old) were studied with SEM, freeze-fracture TEM, freeze-fracture immunogold labeling (FRIL), and filipin cytochemistry for membrane cholesterol detection. Results SEM showed that ball-and-sockets were distributed along the long and short sides of hexagonal fiber cells, whereas protrusions were located along the cell corners, from superficial to deep cortical regions in both chicken and monkey lenses. Importantly, by freeze-fracture TEM, we discovered the selective association of gap junctions with all ball-and-sockets examined, but not with protrusions, in both species. In the embryonic chicken lens (E18), the abundant distribution of ball-and-socket gap junctions was regularly found in an approximate zone extending at least 300 μm deep from the equatorial surface of the superficial cortical fibers. Many ball-and-socket gap junctions often protruded deeply into neighboring cells. However, in the mature fibers of monkey lenses, several ball-and-sockets exhibited only partial occupancy of gap junctions with disorganized connexons, possibly due to degradation of gap junctions during fiber maturation and aging. FRIL analysis confirmed that both connexin46 (Cx46) and connexin50 (Cx50) antibodies specifically labeled ball-and-socket gap junctions, but not protrusions. Furthermore, filipin cytochemistry revealed that the ball-and-socket gap junctions contained different amounts of cholesterol (i.e., cholesterol-rich versus cholesterol-free) as seen with the filipin-cholesterol-complexes (FCC) in different cortical regions during maturation. In contrast, the protrusions contained consistently high cholesterol amounts (i.e., 402 FCCs/μm2 membrane) which were approximately two times greater than that of the cholesterol-rich gap junctions (i.e., 188 FCCs/μm2 membrane) found in ball-and-sockets. Conclusions Gap junctions are regularly associated with all ball-and-sockets examined in metabolically active young cortical fibers, but not with protrusions, in both chicken and monkey lenses. Since these unique gap junctions often protrude deeply into neighboring cells to increase membrane surface areas, they may significantly facilitate cell-to-cell communication between young cortical fiber cells. In particular, the large number of ball-and-socket gap junctions found near the equatorial region may effectively facilitate the flow of outward current toward the equatorial surface for internal circulation of ions in the lens. In contrast, a consistent distribution of high concentrations of cholesterol in protrusions would make the protrusion membrane less deformable and would be more suitable for maintaining fiber-to-fiber stability during visual accommodation. Thus, the ball-and-sockets and protrusions are two structurally and functionally distinct membrane domains in the lens. PMID:21139982
... end of the femur, which fits in a socket in the pelvis. Your hip is known as a ball-and-socket joint. This is because you have a ball ... of your femur, and it fits into a socket in your pelvis. This makes your hips very ...
Residual-stress measurement in socket welded joints by neutron diffraction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hayashi, M.; Ishiwata, M.; Minakawa, N.
1994-12-31
Neutron diffraction measurements of lattice strains provide spatial maps of residual stress near welds in ferritic steel socket joints. The highest tensile stresses in the welds are found in axial, radial and hoop direction at the weld root. However, the highest tensile stress in the axial direction is about 110MPa. Balancing compressive stresses are found near the surface of the socket weld fusion zone. Heat treatment at 600 C for 2 hours is sufficient to relieve residual stress in socket welds.
Detachable connection for a nuclear reactor fuel assembly
Christiansen, D.W.; Karnesky, R.A.
1983-08-29
A locking connection for releasably attaching a handling socket to the duct tube of a fuel assembly for a nuclear reactor. The connection comprises a load pad housing mechanically attached to the duct tube and a handling socket threadably secured within the housing. A retaining ring is interposed between the housing and the handling socket and is formed with a projection and depression engagable within a cavity and groove of the housing and handling socket, respectively, to form a detachable interlocked connection assembly.
Detachable connection for a nuclear reactor fuel assembly
Christiansen, David W.; Karnesky, Richard A.
1986-01-01
A locking connection for releasably attaching a handling socket to the duct tube of a fuel assembly for a nuclear reactor. The connection comprises a load pad housing mechanically attached to the duct tube and a handling socket threadably secured within the housing. A retaining ring is interposed between the housing and the handling socket and is formed with a projection and depression engageable within a cavity and groove of the housing and handling socket, respectively, to form a detachable interlocked connection assembly.
Karakoç, Mehmet; Batmaz, İbrahim; Sariyildiz, Mustafa Akif; Yazmalar, Levent; Aydin, Abdülkadir; Em, Serda
2017-08-01
Patients with amputation need prosthesis to comfortably move around. One of the most important parts of a good prosthesis is the socket. Currently, the most commonly used method is the traditional socket manufacturing method, which involves manual work; however, computer-aided design/computer-aided manufacturing (CAD/CAM) is also being used in the recent years. The present study aimed to investigate the effects of sockets manufactured by traditional and CAD/CAM method on clinical characteristics and quality of life of patients with transtibial amputation. The study included 72 patients with transtibial amputation using prosthesis, 36 of whom had CAD/CAM prosthetic sockets (group 1) and 36 had traditional prosthetic sockets (group 2). Amputation reason, prosthesis lifetime, walking time and distance with prosthesis, pain-free walking time with prosthesis, production time of the prosthesis, and adaptation time to the prosthesis were questioned. Quality of life was assessed using the 36-item Short Form Health Survey questionnaire and the Trinity Amputation and Prosthesis Experience Scales. Walking time and distance and pain-free walking time with prosthesis were significantly better in group 1 than those in group 2. Furthermore, the prosthesis was applied in a significantly shorter time, and socket adaptation time was significantly shorter in group 1. Except emotional role limitation, all 36-item Short Form Healthy Survey questionnaire parameters were significantly better in group 1 than in group 2. Trinity Amputation and Prosthesis Experience Scales activity limitation scores of group 1 were lower, and Trinity Amputation and Prosthesis Experience Scales satisfaction with the prosthesis scores were higher than those in group 2. Our study demonstrated that the sockets manufactured by CAD/CAM methods yield better outcomes in quality of life of patients with transtibial amputation than the sockets manufactured by the traditional method.
The effect of cancer therapies on pediatric anophthalmic sockets.
Shildkrot, Yevgeniy; Kirzhner, Maria; Haik, Barrett G; Qaddoumi, Ibrahim; Rodriguez-Galindo, Carlos; Wilson, Matthew W
2011-12-01
To determine the impact of chemotherapy or external beam radiotherapy (EBRT) on pediatric anophthalmic sockets. A retrospective, nonrandomized, interventional cohort study. A total of 135 sockets of 133 children undergoing enucleation from late 1999 to early 2009 at the St. Jude Children's Research Hospital were included. A retrospective chart review of outcomes after enucleation in patients treated with systemic chemotherapy or orbital EBRT either before or after removal of the eye compared with patients who received no other treatment. Incidence of implant exposure, migration, extrusion, socket contracture, and pyogenic granuloma formation. Retinoblastoma was the primary diagnosis in 128 eyes (95%). Median follow-up was 3.6 years (range, 0.1-9.3 years). Event-free course was observed in 94 sockets (69.6%). Complications included implant exposure (n = 28, 20.7%), socket contracture (n = 16, 11.9%), pyogenic granuloma (n = 9, 6.7%), implant extrusion (n = 3, 2.2%), and migration (n = 2, 1.5%). Exposure resolved in 21 sockets (77.8%) and improved in 2 sockets (11.1%); 1 patient with exposure died. Use of prior, adjuvant, or subsequent chemotherapy increased the long-term risk of exposure (odds ratio [OR] = 3.7; 95% confidence interval [CI], 1.4-9.4), and contracture (OR could not be calculated, P<0.0001). External beam radiotherapy greatly increased the risk of contracture (OR 24.0; 95% CI, 6.9-82.8) and exposure (OR 2.89; 95% CI, 1.1-7.9). In this unique pediatric population with cancer, chemotherapy and EBRT had an additive effect, significantly increasing the incidence of exposure and socket contracture. The author(s) have no proprietary or commercial interest in any materials discussed in this article. Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
The Effect of Cancer Therapies on Pediatric Anophthalmic Sockets
Shildkrot, Yevgeniy; Kirzhner, Maria; Haik, Barrett G.; Qaddoumi, Ibrahim; Rodriguez-Galindo, Carlos; Wilson, Matthew W.
2012-01-01
Purpose To determine the impact of chemotherapy or external beam radiotherapy (EBRT) on pediatric anophthalmic sockets. Design A retrospective, nonrandomized, interventional cohort study. Participants A total of 135 sockets of 133 children undergoing enucleation from late 1999 to early 2009 at the St. Jude Children’s Research Hospital were included. Methods A retrospective chart review of outcomes after enucleation in patients treated with systemic chemotherapy or orbital EBRT either before or after removal of the eye compared with patients who received no other treatment. Main Outcome Measures Incidence of implant exposure, migration, extrusion, socket contracture, and pyogenic granuloma formation. Results Retinoblastoma was the primary diagnosis in 128 eyes (95%). Median follow-up was 3.6 years (range, 0.1–9.3 years). Event-free course was observed in 94 sockets (69.6%). Complications included implant exposure (n = 28, 20.7%), socket contracture (n = 16, 11.9%), pyogenic granuloma (n = 9, 6.7%), implant extrusion (n = 3, 2.2%), and migration (n = 2, 1.5%). Exposure resolved in 21 sockets (77.8%) and improved in 2 sockets (11.1%); 1 patient with exposure died. Use of prior, adjuvant, or subsequent chemotherapy increased the long-term risk of exposure (odds ratio [OR] = 3.7; 95% confidence interval [CI], 1.4–9.4), and contracture (OR could not be calculated, P<0.0001). External beam radiotherapy greatly increased the risk of contracture (OR 24.0; 95% CI, 6.9–82.8) and exposure (OR 2.89; 95% CI, 1.1–7.9). Conclusions In this unique pediatric population with cancer, chemotherapy and EBRT had an additive effect, significantly increasing the incidence of exposure and socket contracture. PMID:21856015
Kurtul, Bengi Ece; Erdener, Ugur; Mocan, Mehmet Cem; Irkec, Murat; Orhan, Mehmet
2014-01-01
To investigate and compare the cytopathological and clinical effects of amniotic membrane transplantation (AMT) and oral mucosal membrane transplantation (OMMT) in socket contraction. Twelve patients who could not be fitted with ocular prosthesis due to socket contracture were included in this study. Seven patients underwent AMT and 5 patients underwent OMMT. Thirteen patients who had healthy sockets were included as control group. Depth of inferior fornix, degree of inflammation, extent of the socket contracture and socket volume were measured in the preoperative period and at sixth and twelfth weeks postoperatively. Impression cytology of conjunctival fornices and tear transforming growth factor beta-1 (TGFβ1) levels were determined. In the AMT group, socket volume and lower fornix depth values were significantly higher (P=0.030 and P=0.004 respectively) and inflammation levels and impression cytology stages (P=0.037 and P=0.022 respectively) were significantly lower in postoperative period compared to preoperative period. In the OMMT group, no statistical differences were found in terms of clinical parameters, inflammation levels and impression cytology stages of preoperative versus postoperative values. Preoperative tear TGFβ1 levels were higher in AMT and OMMT groups compared to the control group (25.5 ng/mL, 26.3 ng/mL and 21.7 ng/mL respectively). Decreased tear TGFβ1 levels were observed in both the AMT and OMMT groups postoperatively (median decrease value=2.1 ng/mL and 2.7 ng/mL respectively). AMT is associated with postoperative improvement in inferior fornix depth, socket volume, inflammation and impression cytology levels and may be a more proper alternative method than OMMT in the management of socket contracture.
Poulias, Evmenios; Greenwell, Henry; Hill, Margaret; Morton, Dean; Vidal, Ricardo; Shumway, Brian; Peterson, Thomas L
2013-11-01
Previous studies of ridge preservation showed a loss of ≈18% or 1.5 mm of crestal ridge width in spite of treatment. The primary aim of this randomized, controlled, masked clinical trial is to compare a socket graft to the same treatment plus a buccal overlay graft, both with a polylactide membrane, to determine if loss of ridge width can be prevented by use of an overlay graft. Twelve patients who served as positive controls received an intrasocket mineralized cancellous allograft (socket group), and 12 patients received the same socket graft procedure plus buccal overlay cancellous xenograft (overlay group). Horizontal ridge dimensions were measured with a digital caliper, and vertical ridge changes were measured from a stent. Before implant placement, at 4 months, a trephine core was obtained for histologic analysis. The mean horizontal ridge width at the crest for the socket group decreased from 8.7 ± 1.0 to 7.1 ± 1.5 mm for a mean loss of 1.6 ± 0.8 mm (P <0.05), whereas the same measurement for the overlay group decreased from 8.4 ± 1.4 to 8.1 ± 1.4 mm for a mean loss of 0.3 ± 0.9 mm (P >0.05). The overlay group was significantly different from the socket group (P <0.05). Histologic analysis revealed that the socket group had 35% ± 16% vital bone, and the overlay group had 40% ± 16% (P >0.05). The overlay treatment significantly prevented loss of ridge width and preserved or augmented the buccal contour. The socket and overlay groups healed with a high percentage of vital bone.
The modular socket system in a rural setting in Indonesia.
Giesberts, Bob; Ennion, Liezel; Hjelmstrom, Olle; Karma, Agusni; Lechler, Knut; Hekman, Edsko; Bergsma, Arjen
2018-06-01
Prosthetic services are inaccessible to people living in rural areas. Systems like the modular socket system have the potential to be fabricated outside of the prosthetic workshop. This study aimed to evaluate the patient's performance and satisfaction with the use of the modular socket system, and the technical feasibility of its implementation in a rural setting. A quantitative longitudinal descriptive study design was followed. A total of 15 persons with a lower limb amputation were fitted with the modular socket system and followed over 4-6 months. Performance was measured using a 2-min walk test, 10-m walk test and mobility and function questionnaire. Satisfaction was measured by the Socket Fit Comfort Score, Prosthesis Evaluation Questionnaire and EuroQoL 5 Dimensions 5 Levels. Notes on technical feasibility were taken at the moment of fitting ( t 0 ), at 1-3 months post fitting ( t 1 ) and at the end evaluation at 4-6 months post fitting ( t 2 ). Performance did not change between t 0 and t 2 . The comfort of the socket fit reduced between t 0 and t 2 . Satisfaction with prosthesis and general health status stayed constant over time. The average fitting-time for the modular socket system was 6.4 h. The modular socket system can be considered a useful alternative for use in rural settings. Clinical relevance The use of the modular socket system is feasible and can improve accessibility to prosthetic technology in rural areas. Experienced prosthetic users were satisfied with the performance and the device. The shorter manufacturing time and use of only hand-held tools makes it an ideal alternative for use in remote and rural settings.
Kobayashi, Toshiki; Orendurff, Michael S; Zhang, Ming; Boone, David A
2013-04-26
Alignment is important for comfortable and stable gait of lower-limb prosthesis users. The magnitude of socket reaction moments in the multiple planes acting simultaneously upon the residual limb may be related to perception of comfort in individuals using prostheses through socket interface pressures. The aim of this study was to investigate the effect of prosthetic alignment changes on sagittal and coronal socket reaction moment interactions (moment-moment curves) and to characterize the curves in 11 individuals with transtibial amputation using novel moment-moment interaction parameters measured by plotting sagittal socket reaction moments versus coronal ones under various alignment conditions. A custom instrumented prosthesis alignment component was used to measure socket reaction moments during walking. Prosthetic alignment was tuned to a nominally aligned condition by a prosthetist, and from this position, angular (3° and 6° of flexion, extension, abduction or adduction of the socket) and translational (5mm and 10mm of anterior, posterior, medial or lateral translation of the socket) alignment changes were performed in either the sagittal or the coronal plane in a randomized manner. A total of 17 alignment conditions were tested. Coronal angulation and translation alignment changes demonstrated similar consistent changes in the moment-moment curves. Sagittal alignment changes demonstrated more complex changes compared to the coronal alignment changes. Effect of sagittal angulations and translations on the moment-moment curves was different during 2nd rocker (mid-stance) with extension malalignment appearing to cause medio-lateral instability. Presentation of coronal and sagittal socket reaction moment interactions may provide useful visual information for prosthetists to understand the biomechanical effects of malalignment of transtibial prostheses. Copyright © 2013 Elsevier Ltd. All rights reserved.
The reconstruction of a contracted eye socket using a post-auricular full-thickness skin graft.
Wei, Yi Hsuan; Liao, Shu Lang
2014-05-01
To report the efficacy of a full-thickness skin graft (FTSG) for the reconstruction of a contracted eye socket. A retrospective, non-comparative, interventional case series. This was a retrospective review of patients with a contracted eye socket who underwent socket reconstruction using a post-auricular FTSG from 2001 to 2011 at the National Taiwan University Hospital. The postoperative results including prosthetic fitting, the cosmetic result, and eyelid function were assessed. There were 11 male and 15 female patients, with a mean age of 52.3 ± 15.6 years (range 21 to 76). The duration of the socket contracture varied from three months to three years (average 7.4 ± 8.1 months). The severity of the socket contracture ranged from grade 2 to grade 4, based on Tawfik's classification. The mean follow-up time was 35.7 ± 9.6 months. After socket reconstruction, using a post-auricular FTSG, 96% of the cases (25 of 26) demonstrated a successful prosthetic fitting and a satisfactory cosmetic outcome. Both good eyelid function and a stable fornix depth were maintained during the follow-up time. One case received a second socket reconstruction three months after the first operation, using a FTSG, because of an inadequate lateral fornix. The final result was satisfactory. There were no serious complications, but a granuloma formed in one case, and there was prolonged discharge in one case. The reconstruction of a contracted eye socket using a post-auricular FTSG is an effective method with a high success rate, which causes less discomfort to donor sites and results in few complications.
Kotsakis, Georgios A; Joachim, Frederic P C; Saroff, Stephen A; Mahesh, Lanka; Prasad, Hari; Rohrer, Michael D
2014-01-01
The objective of this study was to evaluate bone regeneration in 24 sockets grafted with a calcium phosphosilicate putty alloplastic bone substitute. A core was obtained from 17 sockets prior to implant placement for histomorphometry at 5 to 6 months postextraction. Radiographic analysis during the same postextraction healing period showed radiopaque tissue in all sockets. Histomorphometric analysis revealed a mean vital bone content of 31.76% (± 14.20%) and residual graft content of 11.47% (± 8.99%) after a mean healing period of 5.7 months. The high percentage of vital bone in the healed sites in combination with its timely absorption rate suggest that calcium phosphosilicate putty can be a reliable choice for osseous regeneration in extraction sockets.
Reusable vibration resistant integrated circuit mounting socket
DOE Office of Scientific and Technical Information (OSTI.GOV)
Evans, C.N.
1993-12-31
This invention discloses a novel form of socket for integrated circuits to be mounted on printed circuit boards. The socket uses a novel contact which is fabricated out of a bimetallic strip with a shape which makes the end of the strip move laterally as temperature changes. The end of the strip forms a barb which digs into an integrated circuit lead at normal temperatures and hold it firmly in the contact, preventing loosening and open circuits from vibration. By cooling the contact containing the bimetallic strip the barb end can be made to release so that the integrated circuitmore » lead can be removed from the socket without damage either to the lead or to the socket components.« less
Reusable vibration resistant integrated circuit mounting socket
DOE Office of Scientific and Technical Information (OSTI.GOV)
Evans, C.N.
1995-08-29
This invention discloses a novel form of socket for integrated circuits to be mounted on printed circuit boards. The socket uses a novel contact which is fabricated out of a bimetallic strip with a shape which makes the end of the strip move laterally as temperature changes. The end of the strip forms a barb which digs into an integrated circuit lead at normal temperatures and holds it firmly in the contact, preventing loosening and open circuits from vibration. By cooling the contact containing the bimetallic strip the barb end can be made to release so that the integrated circuitmore » lead can be removed from the socket without damage either to the lead or to the socket components. 11 figs.« less
Prosthetic Correction of Postenucleation Socket Syndrome: A Case Report.
Kamble, Vikas B
2014-12-01
Postenucleation socket syndrome is a frequent late complication of enucleation of eye globe. Several pathophysiological mechanisms have been proposed to account for the symptoms of postenucleation socket syndrome, which include lost orbital volume, superior sulcus deformity, upper eyelid ptosis, lower eyelid laxity, and backward tilt of the prosthesis. The goal of postenucleation socket syndrome treatment is to achieve the best possible functional and esthetic result. The treatment can be either conservative or surgical. For the patient interested in a non-surgical correction, the conservative treatment is simple and non invasive and can be done with prosthesis modification for good positioning, comfort, and mobility. This paper describes prosthetic correction of a patient with postenucleation socket syndrome by modified ocular prosthesis.
Shakibaie-M, Behnam
2013-01-01
The aim of this study was to compare the effectiveness of two bone substitute materials for socket preservation after tooth extraction. Extraction sockets in 10 patients were filled with either inorganic bovine bone material (Bio-Oss) or with synthetic material consisting of hydroxyapatite and silicon dioxide (NanoBone). Extraction sockets without filling served as the control. The results demonstrate the effectiveness of the presented protocol for socket preservation and that the choice of a suitable bone substitute material is crucial. The dimensions of the alveolar ridge were significantly better preserved with Bio-Oss than with NanoBone or without treatment. Bio-Oss treatment resulted in better bone quality and quantity for successful implant placement.
Kostyuk, Vladimir; Potapovich, Alla; Stancato, Andrea; De Luca, Chiara; Lulli, Daniela; Pastore, Saveria; Korkina, Liudmila
2012-01-01
The study aimed to identify endogenous lipid mediators of metabolic and inflammatory responses of human keratinocytes to solar UV irradiation. Physiologically relevant doses of solar simulated UVA+UVB were applied to human skin surface lipids (SSL) or to primary cultures of normal human epidermal keratinocytes (NHEK). The decay of photo-sensitive lipid-soluble components, alpha-tocopherol, squalene (Sq), and cholesterol in SSL was analysed and products of squalene photo-oxidation (SqPx) were quantitatively isolated from irradiated SSL. When administered directly to NHEK, low-dose solar UVA+UVB induced time-dependent inflammatory and metabolic responses. To mimic UVA+UVB action, NHEK were exposed to intact or photo-oxidised SSL, Sq or SqPx, 4-hydroxy-2-nonenal (4-HNE), and the product of tryptophan photo-oxidation 6-formylindolo[3,2-b]carbazole (FICZ). FICZ activated exclusively metabolic responses characteristic for UV, i.e. the aryl hydrocarbon receptor (AhR) machinery and downstream CYP1A1/CYP1B1 gene expression, while 4-HNE slightly stimulated inflammatory UV markers IL-6, COX-2, and iNOS genes. On contrast, SqPx induced the majority of metabolic and inflammatory responses characteristic for UVA+UVB, acting via AhR, EGFR, and G-protein-coupled arachidonic acid receptor (G2A). Conclusions/Significance Our findings indicate that Sq could be a primary sensor of solar UV irradiation in human SSL, and products of its photo-oxidation mediate/induce metabolic and inflammatory responses of keratinocytes to UVA+UVB, which could be relevant for skin inflammation in the sun-exposed oily skin. PMID:22952984
2012-10-01
materials to facilitate dissemination of this technique. 15. SUBJECT TERMS Transfemoral amputation, sub-ischial socket, prosthesis , vacuum-assisted...an appropriate mechanical pump to create suitable vacuum for suspension of the prosthesis ...sockets of highly active prosthesis users
Zhou, Fengjuan; Zheng, Xiaofei; Xie, Meng; Mo, Anchun; Wu, Hongkun
2017-06-01
To evaluate the microenvironment changes in the sockets substituted with bovine-derived xenografts during the early healing period. After extraction of the right maxillary incisor of Sprague Dawley rats, 48 rats were randomly divided into 2 groups. The extraction sockets of the test group were filled with Bio-Oss, whereas the control group was allowed to heal without intervention. The bone quality of the extraction sockets was observed through micro-CT and immunohistochemistry. Micro-CT scanning showed that the bone mineral density in the test group was significantly higher than that in the control group during the early healing period, whereas immunohistochemistry showed that the bone formation-related factors were significantly different between the test and control groups. The bovine-derived xenografts may interfere with the healing process of the extraction socket in the early healing stage. Bone formation of the extraction socket was delayed after grafting with bone substitute.
A Unified Approach toward the Development of Swedish as L2: A Processability Account.
ERIC Educational Resources Information Center
Pienemann, Manfred; Hakansson, Gisela
1999-01-01
Aims to put the body of research on Swedish as a second language (SSL) into one coherent framework and to test the predictions deriving from processability theory for Swedish against this empirical database. Surveys the 14 most prominent research projects on SSL, covering wide areas of syntax and morphology in longitudinal and cross-sectional…
Koltsakidou, Α; Antonopoulou, M; Sykiotou, M; Εvgenidou, Ε; Konstantinou, I; Lambropoulou, D A
2017-02-01
In the present study, photo-Fenton and Fenton-like processes were investigated for the degradation and mineralization of the antineoplastic drug 5-fluorouracil (5-FU). For the optimization of photo-Fenton treatment under simulated solar light (SSL) radiation, the effects of several operating parameters (i.e., 5-FU concentration, Fe 3+ , and oxidant concentration) on the treatment efficiency were studied. According to the results, SSL/[Fe(C 2 Ο 4 ) 3 ] 3- /Η 2 Ο 2 process was the most efficient, since faster degradation of 5-FU and higher mineralization percentages were achieved. All the applied processes followed quite similar transformation routes which include defluorination-hydroxylation as well as pyrimidine ring opening, as demonstrated by the transformation products identified by high resolution mass spectrometry analysis. The toxicity of the treated solutions was evaluated using the Microtox assay. In general, low toxicity was recorded for the initial solution and the solution at the end of the photocatalytic treatment, while an increase in the overall toxicity was observed only at the first stages of SSL/Fe 3+ /Η 2 Ο 2 and SSL/Fe 3+ /S 2 O 8 2- processes.
Reis-Filho, Cláudio R; Silva, Elisângela R; Martins, Adalberto B; Pessoa, Fernanda F; Gomes, Paula V N; de Araújo, Mariana S C; Miziara, Melissa N; Alves, José B
2012-05-01
In this study we investigated the possible use of human demineralised dentine matrix (DHDM), obtained from the extracted teeth, as bone graft material and evaluated the expression of vascular endothelial growth factor (VEGF) induced by this material in the healing process of tooth sockets of rats. To evaluate bone regeneration and expression of VEGF induced by DHDM, thirty-two male Wistar rats weighing approximately 200 g were used. After maxillary second molar extraction, the left sockets were filled with DHDM and the right sockets were naturally filled by blood clot (control). The animals were sacrificed at 3, 7, 14 and 21 days after surgery and upper maxillaries were processed for histological, morphometric and immunohistochemical analyses. DHDM was used to evaluate the mechanical effect of bone graft material into sockets. Expression of VEGF was determined by immunohistochemistry in all groups. Our results demonstrated a significant increase in the newly formed bone tissue in sockets of 7, 14 and 21 days and a significant increase in VEGF expression at days 7 and 14 on treated sockets. Our results showed that DHDM increases the expression of VEGF and accelerates the healing process in rats tooth sockets, by stimulating bone deposition and also vessels formation. These results suggest that DHDM has osteoinductive/osteoconductive potential and may represent an efficient grafting material on guided bone regeneration. Copyright © 2011 Elsevier Ltd. All rights reserved.
Fatigue strength of socket welded pipe joint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Higuchi, Makoto; Hayashi, Makoto; Yamauchi, Takayoshi
1995-12-01
Fully reversed four point bending fatigue tests were carried out on small diameter socket welded joints made of carbon steels. Experimental parameters were pipe diameter, thicknesses of pipe and socket wall, throat depth and shape of fillet welds, slip-on and diametral gaps in the socket welding, lack of penetration at the root of fillet welds, and peening of fillet welds. In most cases a fatigue crack started from the root of the fillet, but in the case of higher stress amplitude, it tended to start from the toe of fillet. The standard socket welded joint for a pipe with amore » 50 mm nominal diameter showed a relatively low fatigue strength of 46 MPa in stress amplitude at the 10{sup 7} cycles failure life. This value corresponds to about 1/5 of that for the smoothed base metal specimens in axial fatigue. The fatigue strength decreased with increasing pipe diameter, and increased with increasing thickness of the pipe and socket wall. The effects of throat depth and shape of fillet welds on fatigue strength were not significant. Contrary to expectation, the fatigue strength of a socket welded joint without slip-on gap is Higher than that of the joint with a normal gap. A lack of penetration at the root deleteriously reduced fatigue strength, showing 14 MPa in stress amplitude at the 10{sup 7} cycles failure life for the 50 mm diameter socket joint.« less
An Energy Efficient Protocol For The Internet Of Things
NASA Astrophysics Data System (ADS)
Venčkauskas, Algimantas; Jusas, Nerijus; Kazanavičius, Egidijus; Štuikys, Vytautas
2015-01-01
The Internet of Things (IoT) is a technological revolution that represents the future of computing and communications. One of the most important challenges of IoT is security: protection of data and privacy. The SSL protocol is the de-facto standard for secure Internet communications. The extra energy cost of encrypting and authenticating of the application data with SSL is around 15%. For IoT devices, where energy resources are limited, the increase in the cost of energy is a very significant factor. In this paper we present the energy efficient SSL protocol which ensures the maximum bandwidth and the required level of security with minimum energy consumption. The proper selection of the security level and CPU multiplier, can save up to 85% of the energy required for data encryption.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Consonni, Stefano; LEAP - Laboratorio Energia Ambiente Piacenza, Via Bixio 27, 29100 Piacenza; Vigano, Federico, E-mail: federico.vigano@polimi.it
Highlights: > The amount of waste available for energy recovery is significantly higher than the Unsorted Residual Waste (URW). > Its energy potential is always higher than the complement to 100% of the Source Separation Level (SSL). > Increasing SSL has marginal effects on the potential for energy recovery. > Variations in the composition of the waste fed to WtE plants affect only marginally their performances. > A large WtE plant with a treatment capacity some times higher than a small plant achieves electric efficiency appreciably higher. - Abstract: This article is part of a set of six coordinated papersmore » reporting the main findings of a research project carried out by five Italian universities on 'Material and energy recovery in Integrated Waste Management Systems (IWMS)'. An overview of the project and a summary of the most relevant results can be found in the introductory article of the series. This paper describes the work related to the evaluation of mass and energy balances, which has consisted of three major efforts (i) development of a model for quantifying the energy content and the elemental compositions of the waste streams appearing in a IWMS; (ii) upgrade of an earlier model to predict the performances of Waste-to-Energy (WtE) plants; (iii) evaluation of mass and energy balances of all the scenarios and the recovery paths considered in the project. Results show that not only the amount of material available for energy recovery is significantly higher than the Unsorted Residual Waste (URW) left after Separate Collection (SC), because selection and recycling generate significant amounts of residues, but its heating value is higher than that of the original, gross waste. Therefore, the energy potential of what is left after recycling is always higher than the complement to 100% of the Source Separation Level (SSL). Also, increasing SSL has marginal effects on the potential for energy recovery: nearly doubling SSL (from 35% to 65%) reduces the energy potential only by one fourth. Consequently, even at high SSL energy recovery is a fundamental step of a sustainable waste management system. Variations of SSL do bring about variations of the composition, heating value and moisture content of the material fed to WtE plants, but these variations (i) are smaller than one can expect; (ii) have marginal effects on the performances of the WtE plant. These considerations suggest that the mere value of SSL is not a good indicator of the quality of the waste management system, nor of its energy and environmental outcome. Given the well-known dependence of the efficiency of steam power plants with their power output, the efficiency of energy recovery crucially depends on the size of the IWMS served by the WtE plant. A fivefold increase of the amount of gross waste handled in the IWMS (from 150,000 to 750,000 tons per year of gross waste) allows increasing the electric efficiencies of the WtE plant by about 6-7 percentage points (from 21-23% to 28.5% circa).« less
46 CFR 161.006-4 - Requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... parts: Yoke and pedestal. Housing. Front door. Reflector. Lamp socket. Supply cable. (c) Weight and... socket. The motor lifeboat searchlight shall be provided with a lamp of not less than 80 watts nor more than 100 watts, and a suitable lamp socket. Means shall be provided for adjusting and securing the lamp...
46 CFR 161.006-4 - Requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... parts: Yoke and pedestal. Housing. Front door. Reflector. Lamp socket. Supply cable. (c) Weight and... socket. The motor lifeboat searchlight shall be provided with a lamp of not less than 80 watts nor more than 100 watts, and a suitable lamp socket. Means shall be provided for adjusting and securing the lamp...
46 CFR 161.006-4 - Requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... parts: Yoke and pedestal. Housing. Front door. Reflector. Lamp socket. Supply cable. (c) Weight and... socket. The motor lifeboat searchlight shall be provided with a lamp of not less than 80 watts nor more than 100 watts, and a suitable lamp socket. Means shall be provided for adjusting and securing the lamp...
46 CFR 161.006-4 - Requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... parts: Yoke and pedestal. Housing. Front door. Reflector. Lamp socket. Supply cable. (c) Weight and... socket. The motor lifeboat searchlight shall be provided with a lamp of not less than 80 watts nor more than 100 watts, and a suitable lamp socket. Means shall be provided for adjusting and securing the lamp...
46 CFR 161.006-4 - Requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... parts: Yoke and pedestal. Housing. Front door. Reflector. Lamp socket. Supply cable. (c) Weight and... socket. The motor lifeboat searchlight shall be provided with a lamp of not less than 80 watts nor more than 100 watts, and a suitable lamp socket. Means shall be provided for adjusting and securing the lamp...
2013-10-01
15. SUBJECT TERMS Transfemoral amputation, sub-ischial socket, prosthesis , vacuum-assisted suspension 16. SECURITY CLASSIFICATION OF: 17...vacuum for suspension of the prosthesis ...14 Task 6 Determine range of volumes to be evacuated from transfemoral sockets of highly active prosthesis users
Convertible socket for pressure gauge
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bissell, R.D.
1990-01-01
This patent describes a pressure gauge having a case in which is disposed a Bourdon tube and a base socket connected to the Bourdon tube for placing the tube in pressure communication with a fluid pressure source. Base socket has a rearward face and a bottom face with respect to the gauge adjacent openings defined through the case and an internal passage communication with the tube. It includes means for connecting a source of fluid pressure to the socket selectively through one of the case openings to the bottom face or the rearward face.
The possible nature of socket stars in H II regions
NASA Technical Reports Server (NTRS)
Castelaz, Michael W.
1990-01-01
Close inspection of faint stars (V of about 14 mag) in H II regions show that they appear to be surrounded by circumstellar envelopes of about 10 arcsecs in diameter (as reported by Feibelman in 1989). The present premise is that the sockets are envelopes of obscuring dust which should emit a measurable amount of infrared radiation based on a simple thermal equilibrium model. A search of literature shows that, of 36 socket stars listed by Feibelman, 17 have been measured in the infrared. Of the 17, 14 show excess IR emission. This is very strong evidence that the socket stars are really stars with circumstellar envelopes. Socket stars may be a new type of astronomical object or well-known astronomical objects in environments or evolutionary states not previously seen.
Double arch mirror study. Part 1: Preliminary engineering report
NASA Technical Reports Server (NTRS)
Vukobratovich, D.; Hillman, D.
1983-01-01
In the proposed design, the NASA AMES 20-in double arch mirror is supported by three clamp and flexure assemblies. The mirror clamp consists of a T-shaped Invar-36 member that goes into a similarly shaped socket in the back of the mirror. The mirror socket is made oversize and contacts the clamp only along the conical surface. The clamp is preloaded by a spring washer and pulls the mirror into contact with the flexure. The clamp is then inserted into the mirror socket through a cutout, is rotated 90 deg, and is then pinned in place. Loading conditions considered in socket design are discussed as well as stress in the socket and clamp. Flexure geometry and stress are examined as well as the effects of flexure error and of mirror cell error.
Manavella, Valeria; Romano, Federica; Garrone, Federica; Terzini, Mara; Bignardi, Cristina; Aimetti, Mario
2017-06-01
The aim of this study was to present and validate a novel procedure for the quantitative volumetric assessment of extraction sockets that combines cone-beam computed tomography (CBCT) and image processing techniques. The CBCT dataset of 9 severely resorbed extraction sockets was analyzed by means of two image processing software, Image J and Mimics, using manual and automated segmentation techniques. They were also applied on 5-mm spherical aluminum markers of known volume and on a polyvinyl chloride model of one alveolar socket scanned with Micro-CT to test the accuracy. Statistical differences in alveolar socket volume were found between the different methods of volumetric analysis (P<0.0001). The automated segmentation using Mimics was the most reliable and accurate method with a relative error of 1.5%, considerably smaller than the error of 7% and of 10% introduced by the manual method using Mimics and by the automated method using ImageJ. The currently proposed automated segmentation protocol for the three-dimensional rendering of alveolar sockets showed more accurate results, excellent inter-observer similarity and increased user friendliness. The clinical application of this method enables a three-dimensional evaluation of extraction socket healing after the reconstructive procedures and during the follow-up visits.
Vignoletti, Fabio; Discepoli, Nicola; Müller, Anna; de Sanctis, Massimo; Muñoz, Fernando; Sanz, Mariano
2012-01-01
The purpose of this investigation is to describe histologically the undisturbed healing of fresh extraction sockets when compared to immediate implant placement. In eight beagle dogs, after extraction of the 3P3 and 4P4, implants were inserted into the distal sockets of the premolars, while the mesial sockets were left to heal spontaneously. Each animal provided four socket sites (control) and four implant sites (test). After 6 weeks, animals were sacrificed and tissue blocks were dissected, prepared for ground sectioning. The relative vertical buccal bone resorption in relation to the lingual bone was similar in both test and control groups. At immediate implant sites, however, the absolute buccal bone loss observed was 2.32 (SD 0.36) mm, what may indicate that while an apical shift of both the buccal and lingual bone crest occurred at the implant sites, this may not happen in naturally healing sockets. The results from this investigation showed that after tooth extraction the buccal socket wall underwent bone resorption at both test and control sites. This resorption appeared to be more pronounced at the implant sites, although the limitations of the histological evaluation method utilized preclude a definite conclusion. © 2011 John Wiley & Sons A/S.
Requena-Calla, Silvana; Funes-Rumiche, Italo
2016-04-01
Dry socket is one of the most studied complications in dentistry and several studies have sought an effective and safe method for its prevention and treatment. The aim of this study was to evaluate the effectiveness of intra-alveolar gel chlorhexidine in preventing dry socket after the surgical removal of third molars. The sample involved the treatment of 40 patients who required extraction of third molars impacted, which were randomly assigned to research groups: experimental group (chlorhexidine gel 0.12%) and control group (placebo gel). Performed the extraction was administered 1 mL of chlorhexidine gel or 1 mL of placebo gel within the socket. The removal of suture was on the fifth postoperative day in which the presence or absence of dry socket was evaluated. No relationship between the appearance of dry socket after application of chlorhexidine gel or placebo gel (X2 test, p = 0.311) was found. However, significant differences (U Mann-Whitney test, p = 0.036) in the pain presented on the fifth postoperative day were evident (VAS). The administration of intra-alveolar chlorhexidine gel 0.12% could generate a better response to postoperative pain after the removal of third molars. Third molar surgery, dry socket, chorhexidine gel.
Ball and Socket Ankle: Mechanism and Computational Evidence of Concept.
Jastifer, James R; Gustafson, Peter A; Labomascus, Aaron; Snoap, Tyler
The ball and socket ankle joint is a morphologically abnormal joint characterized by rounding of the articular surface of the talus. Other than anecdotal observation, little evidence has been presented to describe the development of this deformity. The purpose of the present study was to review ankle and subtalar joint mechanics and to kinematically examine the functional combination of these joints as a mechanism of the ball and socket ankle deformity. We reviewed functional representations of the ankle joint, subtalar joint, and ball and socket ankle deformity. A computational study of joint kinematics was then performed using a 3-dimensional model derived from a computed tomography scan of a ball and socket deformity. The joint kinematics were captured by creating a "virtual map" of the combined kinematics of the ankle and subtalar joints in the respective models. The ball and socket ankle deformity produces functionally similar kinematics to a combination of the ankle and subtalar joints. The findings of the present study support the notion that a possible cause of the ball and socket deformity is bony adaptation that compensates for a functional deficit of the ankle and subtalar joints. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Jiang, Xi; Zhang, Yu; Chen, Bo; Lin, Ye
2017-04-01
Extraction socket remodeling and ridge preservation strategies have been extensively explored. To evaluate the efficacy of applying a micro-titanium stent as a pressure bearing device on extraction socket remodeling of maxillary anterior tooth. Twenty-four patients with a extraction socket of maxillary incisor were treated with spontaneous healing (control group) or by applying a micro-titanium stent as a facial pressure bearing device over the facial bone wall (test group). Two virtual models obtained from cone beam computed tomography data before extraction and 4 months after healing were 3-dimenionally superimposed. Facial bone wall resorption, extraction socket remodeling features and ridge width preservation rate were determined and compared between the groups. Thin facial bone wall resulted in marked resorption in both groups. The greatest palatal shifting distance of facial bone located at the coronal level in the control group, but middle level in the test group. Compared with the original extraction socket, 87.61 ± 5.88% ridge width was preserved in the test group and 55.09 ± 14.46% in the control group. Due to the facial pressure bearing property, the rigid micro-titanium stent might preserve the ridge width and alter the resorption features of extraction socket. © 2016 Wiley Periodicals, Inc.
Gerard, David A; Carlson, Eric R; Gotcher, Jack E; Pickett, David O
2014-01-01
This study was conducted with 2 purposes. The first was to determine the effect of a single dose of zoledronic acid (ZA) on the healing of a tooth extraction socket in dogs. The second was to determine if placement of recombinant human bone morphogenetic protein-2 (rhBMP-2)/absorbable collagen sponge (ACS) - INFUSE, (Medtronic, Memphis, TN) into these extraction sockets would inhibit the inhibition on bone healing and remodeling by ZA. Nine adult female beagle dogs (2 to 3 yr old) were placed into 3 groups of 3 dogs each. Group I received 15 mL of sterile saline intravenously; group II received 2.5 mg of ZA intravenously; and group III received 5 mg of ZA intravenously. Forty-five days after treatment, all dogs underwent extraction of noncontiguous right and left mandibular first molars and second premolars. In group I, the right mandibular extraction sockets had nothing placed in them, whereas the left mandibular sockets had only ACS placed in them. In groups II and III, the right mandibular sockets had rhBMP-2/ACS placed in them, whereas the left mandibular sockets had only ACS placed. All extraction sockets were surgically closed. Tetracycline was given intravenously 5 and 12 days later, and all animals were euthanized 15 days after tooth extraction. The extraction sockets and rib and femur samples were harvested immediately after euthanasia, processed, and studied microscopically. A single dose of ZA significantly inhibited healing and bone remodeling in the area of the tooth extractions. The combination of rhBMP-2/ACS appeared to over-ride some of the bone remodeling inhibition of the ZA and increased bone fill in the extraction sites, and remodeling activity in the area was noted. The effects of rhBMP-2/ACS were confined to the area of the extraction sockets because bone activity at distant sites was not influenced. A single dose of ZA administered intravenously inhibits early healing of tooth extraction sockets and bone remodeling in this animal model. The combination of rhBMP-2/ACS significantly increased bone fill and bone remodeling in these areas, negating much of the effect of the ZA. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Heberer, Susanne; Wustlich, Alexander; Lage, Hermann; Nelson, John J; Nelson, Katja
2012-01-01
The aim of the present clinical study was the evaluation of the osteogenic potential of mesenchymal cells embedded in the provisional matrix of non-augmented and with Bio-Oss collagen-augmented human extraction sockets after 6 weeks of healing time. Twenty-five patients with 47 extraction sites participated in the present study. After tooth removal, the extraction sockets were augmented with Bio-Oss collagen or not augmented. At implant placement, bone biopsies of the extraction sockets were obtained. The immunohistochemical analysis of the osteogenic potential of the mesenchymal cells in the provisional matrix was performed using three monoclonal antibodies: core-binding factor α1 (Cbfa1)/runt-related protein (Runx)2, osteonectin (OSN/secreted protein acidic and rich in cyst [SPARC]) and osteocalcin (OC). The statistical analysis was performed using two-factorial analysis for repeated measures, Mann-Whitney U-test and Spearman's rank-order correlation coefficient. Of 47 extraction sockets examined, 17 sockets demonstrated an almost complete ossification. Hence, the provisional matrix of the 30 remaining extraction sockets (21 non-augmented, 9 augmented) was immunohistochemically investigated. No evidence of acute or chronic inflammation was noted in any of the specimens. In the provisional matrix of the non-grafted socket, the median amount of Cbfa1/Runx2-positive cells was 72.3%, of OSN (SPARC) 66.9% and of OC 23.4%, whereas in the grafted sockets the median rate of immunopositive cells staining with Cbfa1/Runx2 was 73.3%, of OSN (SPARC) 61.4% and of OC 20.1%. There was no significant difference in the proportion of positive cells expressed by Cbfa1/Runx2, OSN/SPARC and OC between the grafted and non-grafted socket. Furthermore, the cell density did not correlate to the quantity of stained cells independent of the used proteins. After a 6-week healing period, the provisional matrix was demonstrated to have a high proportion of cells displaying a maturation of mature osteoprogenitor cells to osteoblasts. The grafting procedure did not influence the quantity of osteogenic cells in the extraction socket. © 2011 John Wiley & Sons A/S.
Samitier, C Beatriz; Guirao, Lluis; Costea, Maria; Camós, Josep M; Pleguezuelos, Eulogio
2016-02-01
Lower limb amputation leads to impaired balance, ambulation, and transfers. Proper fit of the prosthesis is a determining factor for successful ambulation. Vacuum-assisted socket systems extract air from the socket, which decreases pistoning and probability of soft-tissue injuries and increases proprioception and socket comfort. To investigate the effect of vacuum-assisted socket system on transtibial amputees' performance-based and perceived balance, transfers, and gait. Quasi-experimental before-and-after study. Subjects were initially assessed using their prosthesis with the regular socket and re-evaluated 4 weeks after fitting including the vacuum-assisted socket system. We evaluated the mobility grade using Medicare Functional Classification Level, Berg Balance Scale, Four Square Step Test, Timed Up and Go Test, the 6-Min Walk Test, the Locomotor Capabilities Index, Satisfaction with Prosthesis (SAT-PRO questionnaire), and Houghton Scale. A total of 16 unilateral transtibial dysvascular amputees, mean age 65.12 (standard deviation = 10.15) years. Using the vacuum-assisted socket system, the patients significantly improved in balance, gait, and transfers: scores of the Berg Balance Scale increased from 45.75 (standard deviation = 6.91) to 49.06 (standard deviation = 5.62) (p < 0.01), Four Square Step Test decreased from 18.18 (standard deviation = 3.84) s to 14.97 (3.9) s (p < 0.01), Timed Up and Go Test decreased from 14.3 (standard deviation = 3.29) s to 11.56 (2.46) s (p < 0.01). The distance walked in the 6-Min Walk Test increased from 288.53 (standard deviation = 59.57) m to 321.38 (standard deviation = 72.81) m (p < 0.01). Vacuum-assisted socket systems are useful for improving balance, gait, and transfers in over-50-year-old dysvascular transtibial amputees. This study gives more insight into the use of vacuum-assisted socket systems to improve elderly transtibial dysvascular amputees' functionality and decrease their risk of falls. The use of an additional distal valve in the socket should be considered in patients with a lower activity level. © The International Society for Prosthetics and Orthotics 2014.
2012-11-01
TSL Soils Utilizing Growth Benchmarks for Alfalfa , Barnyard Grass, and Perennial Ryegrass ............................................. 5 3...Derivation of Terrestrial Plant-Based Draft Eco-SSL Value for RDX Weathered-and-Aged in SSL or TSL Soils Utilizing Growth Benchmarks for Alfalfa ...studies were conducted using the following plant species: Dicotyledonous symbiotic species alfalfa (Medicago sativa L.) Monocotyledonous
ERIC Educational Resources Information Center
Maina, Nyambura Susan; McGaughey, Trisha; Wade, Julie
2013-01-01
The purpose of this study was to examine the impact of the English for Speakers of Other Languages (ESOL) Student Service Learning (SSL) Club on academic and non-academic outcomes for students receiving ESOL services during 2012-2013 in six high schools in Montgomery County (Maryland) Public Schools (MCPS). The ESOL SSL Club convenes regularly…
Efficient Transmission of DoD PKI Certificates in Tactical Networks
2010-01-01
011 the COlll- mand line. To extract individual fields from cert ifica tes, we used the X.509 subset of the C API included with OpenSSL (vl.O.0-bcta2...www.disa.mil/nces. [17J NSA Suite Il Cryptogt"aphy. http://vvv . nsa.gov/ial programs/suiteb_cryptography/index.shtml. [18J OpenSSL : The Open Source toolk
Rita C.L.B. Rodrigues; Chenfeng Lu; Bernice Liu; Thomas W. Jeffries
2008-01-01
Spent sulfite pulping liquor (SSL) contains lignin, which is present as lignosulfonate, and hemicelluloses that are present as hydrolyzed carbohydrates. To reduce the biological oxygen demand of SSL associated with dissolved sugars, we studied the capacity of Pichia stipitis FPL-YS30 (xyl3[delta]) to convert these sugars into useful products. FPL-YS30 produces a...
Exterior LED Lighting Projects at Princeton University
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davis, Robert G.; Evans, William; Murphy, Arthur T.
For this report, PNNL / the U.S. Department of Energy (DOE) studied a series of past exterior lighting projects at Princeton, in order to document Princeton’s experiences with solid-state lighting (SSL) and the lessons learned along the way, and to show how their approach to SSL projects evolved as their own learning expanded and as the products available improved in performance and sophistication.
Projections of extreme storm surge levels along Europe
NASA Astrophysics Data System (ADS)
Vousdoukas, Michalis I.; Voukouvalas, Evangelos; Annunziato, Alessandro; Giardino, Alessio; Feyen, Luc
2016-11-01
Storm surges are an important coastal hazard component and it is unknown how they will evolve along Europe's coastline in view of climate change. In the present contribution, the hydrodynamic model Delft3D-Flow was forced by surface wind and atmospheric pressure fields from a 8-member climate model ensemble in order to evaluate dynamics in storm surge levels (SSL) along the European coastline (1) for the baseline period 1970-2000; and (2) during this century under the Representative Concentration Pathways RCP4.5 and RCP8.5. Validation simulations, spanning from 2008 to 2014 and driven by ERA-Interim atmospheric forcing, indicated good predictive skill (0.06 m < RMSE < 0.29 m and 10 % < RMSE < 29 % for 110 tidal gauge stations across Europe). Peak-over-threshold extreme value analysis was applied to estimate SSL values for different return periods, and changes of future SSL were obtained from all models to obtain the final ensemble. Values for most scenarios and return periods indicate a projected increase in SSL at several locations along the North European coastline, which is more prominent for RCP8.5 and shows an increasing tendency towards the end of the century for both RCP4.5 and RCP8.5. Projected SSL changes along the European coastal areas south of 50°N show minimal change or even a small decrease, with the exception of RCP8.5 under which a moderate increase is projected towards the end of the century. The present findings indicate that the anticipated increase in extreme total water levels due to relative sea level rise (RSLR), can be further enforced by an increase of the extreme SSL, which can exceed 30 % of the RSLR, especially for the high return periods and pathway RCP8.5. This implies that the combined effect could increase even further anticipated impacts of climate change for certain European areas and highlights the necessity for timely coastal adaptation and protection measures. The dataset is publicly available under this link: http://data.jrc.ec.europa.eu/collection/LISCOAST.
An Amino Acid Code for β-sheet Packing Structure
Joo, Hyun; Tsai, Jerry
2014-01-01
To understand the relationship between protein sequence and structure, this work extends the knob-socket model in an investigation of β-sheet packing. Over a comprehensive set of β-sheet folds, the contacts between residues were used to identify packing cliques: sets of residues that all contact each other. These packing cliques were then classified based on size and contact order. From this analysis, the 2 types of 4 residue packing cliques necessary to describe β-sheet packing were characterized. Both occur between 2 adjacent hydrogen bonded β-strands. First, defining the secondary structure packing within β-sheets, the combined socket or XY:HG pocket consists of 4 residues i,i+2 on one strand and j,j+2 on the other. Second, characterizing the tertiary packing between β-sheets, the knob-socket XY:H+B consists of a 3 residue XY:H socket (i,i+2 on one strand and j on the other) packed against a knob B residue (residue k distant in sequence). Depending on the packing depth of the knob B residue, 2 types of knob-sockets are found: side-chain and main-chain sockets. The amino acid composition of the pockets and knob-sockets reveal the sequence specificity of β-sheet packing. For β-sheet formation, the XY:HG pocket clearly shows sequence specificity of amino acids. For tertiary packing, the XY:H+B side-chain and main-chain sockets exhibit distinct amino acid preferences at each position. These relationships define an amino acid code for β-sheet structure and provide an intuitive topological mapping of β-sheet packing. PMID:24668690
Evaluation of osteoblastic activity in extraction sockets treated with platelet-rich fibrin
Tumer, Celal; Ugur, Omer; Vatankulu, Betul
2015-01-01
Objective: The aim of this study was to determine whether the use of platelet rich fibrin (PRF) improved the healing of extraction sockets. Study Design: A total of 20 patients with bilateral soft tissue impacted mandibular third molars were included in this study. The left and right third molars were extracted during the same session. Subsequently, the PRF membrane was randomly administered to one of the extraction sockets, whereas the contra lateral sockets were left without treatment. On postoperative 30. and 90. days, panoramic images and bone scintigrams were taken to evaluate the bone healing between PRF-treated and non-PRF-treated sockets. Also, periodontal evaluation was performed in the same control sessions. Dependent group t test for paired samples was used for statistical analysis. Results: The average increase in technetium-99m methylene diphosphonate uptake as an indication of enhanced bone healing did not differ significantly between PRF-treated and non-PRF-treated sockets 30 and 90 days post operatively. Radio opacity that can show the bone healing on panoramic images were measured by Image J programmer and they did not differ significantly. Also periodontal values did not differ significantly. Conclusions: PRF might not lead to enhanced bone healing in impacted mandibular third molar extraction sockets 30 and 90 days after surgery. It is thought that PRF has the potential characteristics of an autologous fibrin matrix and can accelerate the healing. To better understand the effects of PRF on healing, further research is warranted with larger sample sizes. Key words:PRF, scintigraphy, healing, extraction sockets. PMID:25475771
Platelet rich fibrin in the management of established dry socket.
Chakravarthi, Srinivas
2017-06-01
Dry socket may occur secondary to the removal of any tooth. However, most dry socket cases develop in the third molar region. Dry socket is multifactorial in nature and has been treated using various modalities with varying success rates. This study assessed the efficacy of platelet rich fibrin (PRF) in established dry socket. Ten patients of either sex aged from 41 to 64 years with established dry socket according to established criteria were treated using PRF. Evaluation was performed by observing the reduction of pain using visual analogue scale, analgesic tablet use over the follow-up period, and healing parameters. Pain was reduced on the first day in all patients with decreased analgesic use. Pain was drastically reduced during follow-up on the first, second, third, and seventh days with a fall in pain score of 0 to 1 after the first day alone. The pain scores of all patients decreased to 1 by the first day except in one patient, and the scores decreased to 0 in all patients after 48 hours. Total analgesic intake ranged from 2 to 6 tablets (aceclofenac 100 mg per tablet) over the follow-up period of 7 days. Healing was satisfactory in all patients by the end of the seventh day. PRF showed early pain reduction in established dry socket with minimal analgesic intake. No patients had allergic reactions to PRF as it is derived from the patient's own blood. PRF showed good wound healing. Our study suggests that PRF should be considered as a treatment modality for established dry socket.
Kobayashi, Toshiki; Arabian, Adam K.; Orendurff, Michael S.; Rosenbaum-Chou, Teri G.; Boone, David A.
2014-01-01
Background Energy storage and return feet are designed for active amputees. However, little is known about the socket reaction moments in transtibial prostheses with energy storage and return feet. The aim of this study was to investigate the effect of alignment changes on the socket reaction moments during gait while using the energy storage and return feet. Methods A Smart Pyramid™ was used to measure the socket reaction moments in 10 subjects with transtibial prostheses while walking under 25 alignment conditions, including a nominal alignment (as defined by conventional clinical methods), as well as angle malalignments of 2°, 4° and 6° (flexion, extension, abduction, and adduction) and translation malalignments of 5mm, 10mm and 15mm (anterior, posterior, lateral, and medial) referenced from the nominal alignment. The socket reaction moments of the nominal alignment were compared with each malalignment. Findings Both coronal and sagittal alignment changes demonstrated systematic effects on the socket reaction moments. In the sagittal plane, angle and translation alignment changes demonstrated significant differences (P<0.05) in the minimum moment, the moment at 45% of stance and the maximum moment for some comparisons. In the coronal plane, angle and translation alignment changes demonstrated significant differences (P<0.05) in the moment at 30% and 75% of stance for all comparisons. Interpretation The alignment may have systematic effects on the socket reaction moments in transtibial prostheses with energy storage and return feet. The socket reaction moments could potentially be a useful biomechanical parameter to evaluate the alignment of the transtibial prostheses. PMID:24315709
Sharma, Ashish; Aggarwal, Nimish; Rastogi, Sanjay; Choudhury, Rupshikha; Tripathi, Siddhi
2017-01-01
To assess the efficacy of platelet-rich fibrin (PRF) on the pain and healing of the extraction socket related with established alveolar osteitis (dry socket, AO) after the removal of maxillary and mandibular molars. One hundred consecutive adult patients with age group ranging from 18 to 40 years along with established dry socket after maxillary and mandibular molar extractions who have not received any treatment for the same were included in this single-arm clinical trial. PRF was placed in the maxillary and mandibular molar extraction sockets after adequate irrigation of the socket. All the patients evaluated for the various study variables which include pain, degree of inflammation, and healthy granulation tissue formation (wound healing) at the 1 st , 3 rd , 7 th , and 14 th post-PRF placement day in the alveolar socket. Data were analyzed using Shapiro-Wilk's test, Chi-square test and/or Student's t -test, Friedman's test, Wilcoxon signed-rank test, and Bonferroni test, with the significance level set at P < 0.05. There was significant reduction in pain associated with AO at the 3 rd and 7 th post-PRF placement day in the extraction socket along with mark decrease in the degree of inflammation at the 3 rd post-PRF placement day, and there was better wound healing by the end of the 2 nd week. The use of PRF in this clinical trial illustrates the promising results in terms of reduced pain and better healing in the patients with sustained AO.
Moghaddas, Hamid; Amjadi, Mohammad Reza; Naghsh, Narges
2012-11-01
Alveolar ridge preservation following tooth extraction has the ability to maintain the ridge dimensions and allow the implant placement in an ideal position fulfilling both functional and aesthetic results. The aim of this study was to evaluate the efficacy of the palatal connective tissue as a biological membrane for socket preservation with demineralized freeze-dried bone allograft (DFDBA). Twelve extraction sites were treated with DFDBA with (case group) and without (control group) using autogenous palatal connective tissue membrane before placement of implants. Alveolar width and height, amount of keratinized tissue, and gingival level were measured at pre-determined points using a surgical stent at two times, the time of socket preservation surgery. In both groups a decrease in all socket dimensions was found. The average decrease in socket width, height, keratinized tissue, and gingival level in case group was 1.16, 0.72, 3.58, and 1.27 mm, and in control group was 2.08, 0.86, 4.52, and 1.58 mm respectively. Statistical analysis showed that decrease in socket width (P = 0.012), keratinized tissue (P ≤ 0.001), and gingival level (P = 0.031) in case group was significantly lower than that of the control group. Results showed no meaningful difference in socket height changes when compared with case and control groups (P = 0.148). Under the limits of this study, connective tissue membrane could preserve socket width, amount of keratinized tissue, and the gingival level more effectively than DFDBA alone.
Platelet rich fibrin in the management of established dry socket
2017-01-01
Objectives Dry socket may occur secondary to the removal of any tooth. However, most dry socket cases develop in the third molar region. Dry socket is multifactorial in nature and has been treated using various modalities with varying success rates. This study assessed the efficacy of platelet rich fibrin (PRF) in established dry socket. Materials and Methods Ten patients of either sex aged from 41 to 64 years with established dry socket according to established criteria were treated using PRF. Evaluation was performed by observing the reduction of pain using visual analogue scale, analgesic tablet use over the follow-up period, and healing parameters. Results Pain was reduced on the first day in all patients with decreased analgesic use. Pain was drastically reduced during follow-up on the first, second, third, and seventh days with a fall in pain score of 0 to 1 after the first day alone. The pain scores of all patients decreased to 1 by the first day except in one patient, and the scores decreased to 0 in all patients after 48 hours. Total analgesic intake ranged from 2 to 6 tablets (aceclofenac 100 mg per tablet) over the follow-up period of 7 days. Healing was satisfactory in all patients by the end of the seventh day. Conclusion PRF showed early pain reduction in established dry socket with minimal analgesic intake. No patients had allergic reactions to PRF as it is derived from the patient's own blood. PRF showed good wound healing. Our study suggests that PRF should be considered as a treatment modality for established dry socket. PMID:28770156
Kobayashi, Toshiki; Orendurff, Michael S.; Arabian, Adam K.; Rosenbaum-Chou, Teri G.; Boone, David A.
2014-01-01
The alignment of a lower limb prosthesis affects the way load is transferred to the residual limb through the socket, and this load is critically important for the comfort and function of the prosthesis. Both magnitude and duration of the moment are important factors that may affect the residual limb health. Moment impulse is a well-accepted measurement that incorporates both factors via moment–time integrals. The aim of this study was to investigate the effect of alignment changes on the socket reaction moment impulse in transtibial prostheses. Ten amputees with transtibial prostheses participated in this study. The socket reaction moment impulse was measured at a self-selected walking speed using a Smart Pyramid™ in 25 alignment conditions, including a nominal alignment (clinically aligned by a prosthetist), as well as angle malalignments of 2°, 4° and 6° (abduction, adduction, extension and flexion) and translation malalignments of 5 mm, 10 mm and 15 mm (lateral, medial, anterior and posterior). The socket reaction moment impulse of the nominal alignment was compared for each condition. The relationship between the alignment and the socket reaction moment impulse was clearly observed in the coronal angle, coronal translation and sagittal translation alignment changes. However, this relationship was not evident in the sagittal angle alignment changes. The results of this study suggested that the socket reaction moment impulse could potentially serve as a valuable parameter to assist the alignment tuning process for transtibial prostheses. Further study is needed to investigate the influence of the socket reaction moment impulse on the residual limb health. PMID:24612718
Surface EMG and intra-socket force measurement to control a prosthetic device
NASA Astrophysics Data System (ADS)
Sanford, Joe; Patterson, Rita; Popa, Dan
2015-06-01
Surface electromyography (SEMG) has been shown to be a robust and reliable interaction method allowing for basic control of powered prosthetic devices. Research has shown a marked decrease in EMG-classification efficiency throughout activities of daily life due to socket shift and movement and fatigue as well as changes in degree of fit of the socket throughout the subject's lifetime. Users with the most severe levels of amputation require the most complex devices with the greatest number of degrees of freedom. Controlling complex dexterous devices with limited available inputs requires the addition of sensing and interaction modalities. However, the larger the amputation severity, the fewer viable SEMG sites are available as control inputs. Previous work reported the use of intra-socket pressure, as measured during wrist flexion and extension, and has shown that it is possible to control a powered prosthetic device with pressure sensors. In this paper, we present data correlations of SEMG data with intra-socket pressure data. Surface EMG sensors and force sensors were housed within a simulated prosthetic cuff fit to a healthy-limbed subject. EMG and intra-socket force data was collected from inside the cuff as a subject performed pre-defined grip motions with their dominant hand. Data fusion algorithms were explored and allowed a subject to use both intra-socket pressure and SEMG data as control inputs for a powered prosthetic device. This additional input modality allows for an improvement in input classification as well as information regarding socket fit through out activities of daily life.
Mozzati, Marco; Gallesio, Giorgia; di Romana, Sara; Bergamasco, Laura; Pol, Renato
2014-03-01
To evaluate the efficacy of plasma-rich growth factor (PRGF) in improving socket healing after tooth extraction in diabetic patients. This was a split-mouth study in which each patient also served as the control: the study socket was treated with PRGF, whereas the control socket underwent natural healing. The outcome variables were the Healing Index, residual socket volume, visual analog scale score, postsurgical complications, and outcome of a patient questionnaire. The investigation considered the impact of hyperglycemia, glycated hemoglobin, End Organ Disease Score, and smoking habits. Follow-up included 4 postextraction checkups over a 21-day period. Pairs of correlated continuous variables were analyzed with the Wilcoxon test, independent continuous variables with the Mann-Whitney test, and categorical variables with the χ(2) test or Fisher test. From January 2012 to December 2012, 34 patients affected by insulin-dependent diabetes mellitus underwent contemporary bilateral extractions of homologous teeth. The treatment-versus-control postoperative comparison showed that PRGF resulted in significantly smaller residual socket volumes and better Healing Indices from days 3 to 14. The patients' questionnaire outcomes were unanimously in favor of PRGF treatment. The small sample of patients with glycemia values of at least 240 mg/dL showed worse Healing Index and minor socket decreases. PRGF application after extraction improved the healing process in diabetic patients by accelerating socket closure (epithelialization) and tissue maturation, proving the association between PRGF use and improved wound healing in diabetic patients. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
46 CFR 56.75-30 - Pipe joining details.
Code of Federal Regulations, 2010 CFR
2010-10-01
... be either of the socket or butt type. When butt joints are employed the edges to be joined shall be.... Circumferential joints may be either of the butt or socket type. Where butt joints are employed, the included... annular clearance of socket joints shall be held to small clearances which experience indicates is...
A Microprocessor Development System for the Intel 8748 Microcomputer.
1979-12-01
their ready availability, it was decided to build the system on a 4 x 6 Vector plugboard with a 44 pin connect- or and which was predrilled for wirewrap...8748, additional sockets were provided in a 4 socket mother board. These sockets accept the standard 44 pin Vector plugboard . It is recommended that
46 CFR 56.75-30 - Pipe joining details.
Code of Federal Regulations, 2014 CFR
2014-10-01
... be either of the socket or butt type. When butt joints are employed the edges to be joined shall be.... Circumferential joints may be either of the butt or socket type. Where butt joints are employed, the included... annular clearance of socket joints shall be held to small clearances which experience indicates is...
46 CFR 56.75-30 - Pipe joining details.
Code of Federal Regulations, 2013 CFR
2013-10-01
... be either of the socket or butt type. When butt joints are employed the edges to be joined shall be.... Circumferential joints may be either of the butt or socket type. Where butt joints are employed, the included... annular clearance of socket joints shall be held to small clearances which experience indicates is...
46 CFR 56.75-30 - Pipe joining details.
Code of Federal Regulations, 2012 CFR
2012-10-01
... be either of the socket or butt type. When butt joints are employed the edges to be joined shall be.... Circumferential joints may be either of the butt or socket type. Where butt joints are employed, the included... annular clearance of socket joints shall be held to small clearances which experience indicates is...
46 CFR 56.75-30 - Pipe joining details.
Code of Federal Regulations, 2011 CFR
2011-10-01
... be either of the socket or butt type. When butt joints are employed the edges to be joined shall be.... Circumferential joints may be either of the butt or socket type. Where butt joints are employed, the included... annular clearance of socket joints shall be held to small clearances which experience indicates is...
Development of socketed foundations for S3X5.7 posts.
DOT National Transportation Integrated Search
2015-04-01
The objective of this study was to develop a socketed foundation for use with the S3x5.7 (S76x8.5) weak : post. The design focused on cylindrical, reinforced concrete foundations with a steel tube placed in the center for : use as the socket. The fou...
Extraction socket sealing using palatal gingival grafts and resorbable collagen membranes.
Kim, Sang-Yun; Kim, Young-Kyun; Kim, Hyun-Suk; Yun, Pil-Young; Kim, Su-Gwan; Choi, Yong-Hun
2017-12-01
Socket sealing surgery is performed for the preservation of the form and volume of the soft tissue by covering the resulting socket with autogenous soft tissue graft or membrane barriers. This procedure is usually necessary to improve the esthetic results of the maxillary anterior or premolar areas. This study retrospectively investigated cases involving the open membrane technique or socket sealing surgery with a palatal gingival graft or collagen membrane where implant placement and bone grafting were performed immediately after tooth extraction. From January 2005 to December 2008, socket sealing surgery was performed in 24 patients, and 25 implants were placed. All implants were successful in the follow-up period. In the palatal gingival graft group, the mean marginal bone loss was 1.17 mm during the mean follow-up period of 81.0 months. In the collagen membrane group, the mean marginal bone loss was 1.23 mm during the mean follow-up period of 76.9 months. There was no significant difference between the two groups. Consequently, socket sealing surgery is effective at minimizing the loss of soft tissue and alveolar bone.
IJspeert, Joep E G; Madani, Ariana; Overbeek, Lucy I H; Dekker, Evelien; Nagtegaal, Iris D
2017-05-01
Distinguishing premalignant sessile serrated lesions (SSLs) from hyperplastic polyps (HPs) is difficult for pathologists in daily practice. We aimed to evaluate nationwide variability within histopathology laboratories in the frequency of diagnosing an SSL as compared with an HP within the Dutch population-based screening programme for colorectal cancer and to assess the effect of an e-learning module on interlaboratory consistency. Data were retrieved from the Dutch Pathology Registry from the start of the nationwide population screening programme, January 2014, until December 2015. An obligatory e-learning module was implemented among pathologists in October 2014. The ratio between SSL and HP diagnosis was determined per laboratory. Odds ratios (ORs) for the diagnosis of an SSL per laboratory were compared with the laboratory with the median odds (median laboratory), before and after implementation of the e-learning module. In total, 14 997 individuals with 27 879 serrated polyps were included; 6665 (23.9%) were diagnosed as SSLs, and 21 214 as HPs (76.1%). The ratio of diagnosing an SSL ranged from 5% to 47% (median 23%) within 44 laboratories. Half of the laboratories showed a significantly different OR (range 3.47-0.16) for diagnosing an SSL than the median laboratory. Variability decreased after implementation of the e-learning module (P = 0.02). Of all pathology laboratories, 70% became more consistent with the median laboratory after e-learning implementation. We demonstrated substantial interlaboratory variability in the histopathological diagnosis of SSLs, which significantly decreased after implementation of a structured e-learning module. Widespread implementation of education might contribute to more homogeneous practice among pathologists. © 2016 John Wiley & Sons Ltd.
Pantusa, Manuela; Stirpe, Andrea; Sportelli, Luigi; Bartucci, Rosa
2010-05-01
Electron spin resonance (ESR) spectroscopy is used to study the transfer of stearic acids between human serum albumin (HSA) and sterically stabilized liposomes (SSL) composed of dipalmitoylphosphatidylcholine (DPPC) and of submicellar content of poly(ethylene glycol:2000)-dipalmitoylphosphatidylethanolamine (PEG:2000-DPPE). Protein/lipid dispersions are considered in which spin-labelled stearic acids at the 16th carbon atom along the acyl chain (16-SASL) are inserted either in the protein or in the SSL. Two component ESR spectra with different rotational mobility are obtained over a broad range of temperature and membrane composition. Indeed, superimposed to an anisotropic protein-signal, appears a more isotropic lipid-signal. Since in the samples only one matrix (protein or membranes) is spin-labelled, the other component accounts for the transfer of 16-SASL between albumin and membranes. The two components have been resolved and quantified by spectral subtractions, and the fraction, f (p) (16-SASL), of spin labels bound non-covalently to the protein has been used to monitor the transfer. It is found that it depends on the type of donor and acceptor matrix, on the physical state of the membranes and on the grafting density of the polymer-lipids. Indeed, it is favoured from SSL to HSA and the fraction of stearic acids transferred increases with temperature in both directions of transfer. Moreover, in the presence of polymer-lipids, the transfer from HSA to SSL is slightly attenuated, especially in the brush regime of the polymer-chains. Instead, the transfer from SSL to HSA is favoured by the polymer-lipids much more in the mushroom than in the brush regime.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Consonni, Stefano, E-mail: stefano.consonni@polimi.it; Giugliano, Michele; Massarutto, Antonio
Highlights: > The source separation level (SSL) of waste management system does not qualify adequately the system. > Separately collecting organic waste gives less advantages than packaging materials. > Recycling packaging materials (metals, glass, plastics, paper) is always attractive. > Composting and anaerobic digestion of organic waste gives questionable outcomes. > The critical threshold of optimal recycling seems to be a SSL of 50%. - Abstract: This paper describes the context, the basic assumptions and the main findings of a joint research project aimed at identifying the optimal breakdown between material recovery and energy recovery from municipal solid waste (MSW)more » in the framework of integrated waste management systems (IWMS). The project was carried out from 2007 to 2009 by five research groups at Politecnico di Milano, the Universities of Bologna and Trento, and the Bocconi University (Milan), with funding from the Italian Ministry of Education, University and Research (MIUR). Since the optimization of IWMSs by analytical methods is practically impossible, the search for the most attractive strategy was carried out by comparing a number of relevant recovery paths from the point of view of mass and energy flows, technological features, environmental impact and economics. The main focus has been on mature processes applicable to MSW in Italy and Europe. Results show that, contrary to a rather widespread opinion, increasing the source separation level (SSL) has a very marginal effects on energy efficiency. What does generate very significant variations in energy efficiency is scale, i.e. the size of the waste-to-energy (WTE) plant. The mere value of SSL is inadequate to qualify the recovery system. The energy and environmental outcome of recovery depends not only on 'how much' source separation is carried out, but rather on 'how' a given SSL is reached.« less
Essau, Cecilia A; Olaya, Beatriz; Sasagawa, Satoko; Pithia, Jayshree; Bray, Diane; Ollendick, Thomas H
2014-01-01
The present study examined the effectiveness of a transdiagnostic prevention programme, Super Skills for Life (SSL), in children with anxiety problems. SSL is based on the principles of cognitive-behaviour therapy (CBT), behavioural activation, social skills training, and uses video-feedback and cognitive preparation as part of the treatment. Participants were 61 primary school children, aged 8-10 years, who were referred by their teachers as having significant anxiety problems. Children were video-recorded during a 2-min speech task in sessions 1 and 8, and during a social interaction task. All the children completed measures of anxiety symptoms, social skills, and self-esteem before and after participating in the 8-week SSL and at the 6-months follow-up assessment. Anxiety symptoms were significantly reduced at post-test and follow-up assessments. SSL also had a positive effect on hyperactivity, conduct, and peer problems although it took longer for these effects to occur. Behavioural indicators of anxiety during the 2-min speech task decreased, indicating that the independent raters observed behavioural change in the children from pre-treatment to follow-up. Boys had higher overall behavioural anxiety during the 2-min speech task at all three assessment periods, specifically showing higher lip contortions and leg movement than girls. The present study used an open clinical trial design, had small sample size, and did not use structured diagnostic interview schedules to assess anxiety disorders. This study provides preliminary empirical support for the effectiveness of SSL in children with anxiety problems. Copyright © 2014 Elsevier B.V. All rights reserved.
Sayari, Adel; Mosbah, Habib; Gargouri, Youssef
2007-05-01
In addition to their physiological importance, microbial lipases, like staphylococcal ones, are of considerable commercial interest for biotechnological applications such as detergents, food production, and pharmaceuticals and industrial synthesis of fine chemicals. The gene encoding the extracellular lipase of Staphylococcus simulans (SSL) was subcloned in the pET-14b expression vector and expressed in Esherichia coli BL21 (DE3). The wild-type SSL was expressed as amino terminal His6-tagged recombinant protein. One-step purification of the recombinant lipase was achieved with nickel metal affinity column. The purified His-tagged SSL (His6-SSL) is able to hydrolyse triacylglycerols without chain length selectivity. The major differences among lipases are reflected in their chemical specificity in the hydrolysis of peculiar ester bonds, and their respective capacity to hydrolyse substrates having different physico-chemical properties. It has been proposed, using homology alignment, that the region around the residue 290 of Staphylococcus hyicus lipase could be involved in the selection of the substrate. To evaluate the importance of this environment, the residue Asp290 of Staphylococcus simulans lipase was mutated to Ala using site-directed mutagenesis. The mutant expression plasmid was also overexpressed in Esherichia coli and purified with a nickel metal affinity column. The substitution of Asp290 by Ala was accompanied by a significant shift of the acyl-chain length specificity of the mutant towards short chain fatty acid esters. Kinetic studies of wild-type SSL and its mutant D290A were carried out, and show essentially that the catalytic efficiency (k cat /K M ) of the mutant was affected. Our results confirmed that Asp290 is important for the chain length selectivity and catalytic efficiency of Staphylococcus simulans lipase.
Development of a residuum/socket interface simulator for lower limb prosthetics.
McGrath, Michael Paul; Gao, Jianliang; Tang, Jinghua; Laszczak, Piotr; Jiang, Liudi; Bader, Dan; Moser, David; Zahedi, Saeed
2017-03-01
Mechanical coupling at the interface between lower limb residua and prosthetic sockets plays an important role in assessing socket fitting and tissue health. However, most research lab-based lower limb prosthetic simulators to-date have implemented a rigid socket coupling. This study describes the fabrication and implementation of a lower limb residuum/socket interface simulator, designed to reproduce the forces and moments present during the key loading phases of amputee walking. An artificial residuum made with model bones encased in silicone was used, mimicking the compliant mechanical loading of a real residuum/socket interface. A 6-degree-of-freedom load cell measured the overall kinetics, having previously been incorporated into an amputee's prosthesis to collect reference data. The developed simulator was compared to a setup where a rigid pylon replaced the artificial residuum. A maximum uniaxial load of 850 N was applied, comparable to the peak vertical ground reaction force component during amputee walking. Load cell outputs from both pylon and residuum setups were compared. During weight acceptance, when including the artificial residuum, compression decreased by 10%, while during push off, sagittal bending and anterior-posterior shear showed a 25% increase and 34% decrease, respectively. Such notable difference by including a compliant residuum further highlighted the need for such an interface simulator. Subsequently, the simulator was adjusted to produce key load cell outputs briefly aligning with those from amputee walking. Force sensing resistors were deployed at load bearing anatomic locations on the residuum/socket interface to measure pressures and were compared to those cited in the literature for similar locations. The development of such a novel simulator provides an objective adjunct, using commonly available mechanical test machines. It could potentially be used to provide further insight into socket design, fit and the complex load transfer mechanics at the residuum/socket interface, as well as to evaluate the structural performance of prostheses.
Verification of OpenSSL version via hardware performance counters
NASA Astrophysics Data System (ADS)
Bruska, James; Blasingame, Zander; Liu, Chen
2017-05-01
Many forms of malware and security breaches exist today. One type of breach downgrades a cryptographic program by employing a man-in-the-middle attack. In this work, we explore the utilization of hardware events in conjunction with machine learning algorithms to detect which version of OpenSSL is being run during the encryption process. This allows for the immediate detection of any unknown downgrade attacks in real time. Our experimental results indicated this detection method is both feasible and practical. When trained with normal TLS and SSL data, our classifier was able to detect which protocol was being used with 99.995% accuracy. After the scope of the hardware event recording was enlarged, the accuracy diminished greatly, but to 53.244%. Upon removal of TLS 1.1 from the data set, the accuracy returned to 99.905%.
Improved Ball-and-Socket Docking Mechanism
NASA Technical Reports Server (NTRS)
Cloyd, Richard; Bryan, Tom
2004-01-01
A proposed docking mechanism would form a ball-and-socket joint in the docked condition. The mechanism could tolerate significant initial misalignment because it would include an alignment cone that would guide the ball into the socket. Like other ball-and-socket joints, the joint would have three rotational degrees of freedom. This docking mechanism would be a successor to the one described in Passive Capture Joint With Three Degrees of Freedom (MFS-31146), NASA Tech Briefs, Vol. 22, No. 7 (July 1998), page 65. It would contain most of the components of the prior mechanism, plus some additional components that would expand its capabilities.
Probe-And-Socket Fasteners For Robotic Assembly
NASA Technical Reports Server (NTRS)
Nyberg, Karen
1995-01-01
Self-alignment and simplicity of actuation make mechanism amenable to robotic assembly. Includes socket, mounted on structure at worksite, and probe, mounted on piece of equipment to be attached to structure at socket. Probe-and-socket mechanism used in conjunction with fixed target aiding in placement of end effector of robot during grasping, and with handle or handles on structure. Intended to enable robot to set up workstation in hostile environment. Workstation then used by astronaut, aquanaut, or other human, spending minimum time in environment. Human concentrates on performing quality work rather than on setting up equipment, with consequent reduction of risk.
El Chaar, Edgard; Oshman, Sarah; Cicero, Giuseppe; Castano, Alejandro; Dinoi, Cinzia; Soltani, Leila; Lee, Yoonjung Nicole
Localized ridge resorption, the consequence of socket collapse, following tooth extraction in the anterior maxilla can adversely affect esthetics, function, and future implant placement. Immediate grafting of extraction sockets may help preserve natural ridge contours, but a lack of available soft tissue can compromise the final esthetic outcome. The presented modified rotated palatal pedicle connective tissue flap is a useful technique for simultaneous soft tissue coverage and augmentation of grafted sockets to improve esthetic outcome. This article delineates its advantages through the presentation of a four-case series using this new technique.
A case series of anophthalmic socket cysts excised utilising fibrin sealant.
Wong, Yun; Clarke, Lucy; Lau, Gordon
2017-10-23
Anophthalmic socket cysts are challenging to remove and incomplete excision has been shown to increase the risk of recurrence. This case series describes a novel technique utilising the fibrin sealant Tisseel (Baxter AG, Vienna, Austria) to retain the socket cyst integrity during surgical removal to facilitate its complete excision. Five patients were included and followed up for a minimum of 1 year, and there were no signs of recurrence in any of the cases. The surgical technique is described and illustrated. This technique is a safe way of simplifying challenging socket cyst surgery.
Postoperative Complications of Dermis-Fat Autografts in the Anophthalmic Socket.
Starks, Victoria; Freitag, Suzanne K
2018-01-01
Reconstruction of the anophthalmic socket allows the use of an ocular prosthesis and rehabilitation of facial appearance. Dermis-fat grafting is one option in volume augmentation of the anophthalmic socket and presents unique benefits, including increased surface area within the socket and the ability to grow with pediatric patients. Postoperative complications of this procedure are relatively common. Minor complications, such as graft hirsutism, keratinization, and conjunctival cysts or granulomas, are managed easily by observation or simple intervention. Major complications, such as graft atrophy, infection, or ulceration, may prevent good prosthesis fit and may require return to the operating room.
Chang, Hao-Hueng; Wang, Yin-Lin; Chiang, Yu-Chih; Chen, Yen-Liang; Chuang, Yu-Horng; Tsai, Shang-Jye; Heish, Kuo-Huang; Lin, Feng-Huei; Lin, Chun-Pin
2014-01-01
A novel chitosan-γPGA polyelectrolyte complex hydrogel (C-PGA) has been developed and proven to be an effective dressing for wound healing. The purpose of this study was to evaluate if C-PGA could promote new bone formation in the alveolar socket following tooth extraction. An animal model was proposed using radiography and histomorphology simultaneously to analyze the symmetrical sections of Wistar rats. The upper incisors of Wistar rats were extracted and the extraction sockets were randomly treated with gelatin sponge, neat chitosan, C-PGA, or received no treatment. The extraction sockets of selected rats from each group were evaluated at 1, 2, 4, or 6 wk post-extraction. The results of radiography and histopathology indicated that the extraction sockets treated with C-PGA exhibited lamellar bone formation (6.5%) as early as 2 wk after the extraction was performed. Moreover, the degree of new bone formation was significantly higher (P < 0.05) in the extraction sockets treated with C-PGA at 6 wk post-extraction than that in the other study groups. In this study, we demonstrated that the proposed animal model involving symmetrical sections and simultaneous radiography and histomorphology evaluation is feasible. We also conclude that the novel C-PGA has great potential for new bone formation in the alveolar socket following tooth extraction. PMID:24658174
Yu, H J; Jia, P; Lv, Z; Qiu, L X
2017-04-01
The aim of this study was to analyze and compare the long-term clinical outcomes of mature third molar autotransplantation in surgically created sockets and fresh extraction sockets with regard to survival and functional success rates. A total of 65 third molars with completely formed roots were autotransplanted in 60 patients (average age 33.1 years). Thirty-six of the teeth were autotransplanted into surgically created sockets with or without guided bone regeneration (GBR; delayed autotransplantation), while 29 were autotransplanted into fresh extraction sockets (immediate autotransplantation; control group). All patients underwent annual clinical and radiographic examinations (average follow-up 9.9 years, range 7-13 years). The survival rates for the control, GBR, and no GBR groups were 93.1%, 95.2%, and 80.0%, respectively, with no significant differences among the groups. There were no statistically significant differences among the groups with regard to the frequency of inflammatory root resorption or root ankylosis. Age did not influence the clinical outcomes. These results suggest that the autotransplantation of third molars with completely formed roots is effective in both surgically created and fresh extraction sockets and provides a high long-term success rate if cases are selected and treated appropriately. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
LaPrè, A K; Price, M A; Wedge, R D; Umberger, B R; Sup, Frank C
2018-04-01
Musculoskeletal modeling and marker-based motion capture techniques are commonly used to quantify the motions of body segments, and the forces acting on them during human gait. However, when these techniques are applied to analyze the gait of people with lower limb loss, the clinically relevant interaction between the residual limb and prosthesis socket is typically overlooked. It is known that there is considerable motion and loading at the residuum-socket interface, yet traditional gait analysis techniques do not account for these factors due to the inability to place tracking markers on the residual limb inside of the socket. In the present work, we used a global optimization technique and anatomical constraints to estimate the motion and loading at the residuum-socket interface as part of standard gait analysis procedures. We systematically evaluated a range of parameters related to the residuum-socket interface, such as the number of degrees of freedom, and determined the configuration that yields the best compromise between faithfully tracking experimental marker positions while yielding anatomically realistic residuum-socket kinematics and loads that agree with data from the literature. Application of the present model to gait analysis for people with lower limb loss will deepen our understanding of the biomechanics of walking with a prosthesis, which should facilitate the development of enhanced rehabilitation protocols and improved assistive devices. Copyright © 2017 John Wiley & Sons, Ltd.
Safari, Mohammad Reza; Meier, Margrit Regula
2015-01-01
This review is an attempt to untangle the complexity of transtibial prosthetic socket fit, determine the most important characteristic for a successful fitting, and perhaps find some indication of whether a particular prosthetic socket type might be best for a given situation. Further, it is intended to provide directions for future research. We followed the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines and used medical subject headings and standard key words to search for articles in relevant databases. No restrictions were made on study design or type of outcome measure. From the obtained search results (n = 1,863), 35 articles were included. The relevant data were entered into a predefined data form that incorporated the Downs and Black risk of bias assessment checklist. Results for the qualitative outcomes (n = 19 articles) are synthesized. Total surface bearing sockets lead to greater activity levels and satisfaction in active persons with amputation, those with a traumatic cause of amputation, and younger persons with amputation than patellar tendon bearing sockets. Evidence on vacuum-assisted suction and hydrostatic sockets is inadequate, and further studies are much needed. To improve the scientific basis for prescription, comparison of and correlation between mechanical properties of interface material, socket designs, user characteristics, and outcome measures should be conducted and reported in future studies.
Mandour, Sameh S; Elmazar, Hesham M; Marey, Hatem M; Rahman, Ahmed K Abdel; Sakr, Rokia A
2016-12-01
To evaluate the use of intraoperative topical application of mitomycin C (MMC) for managing cases of recurrent socket contraction. A prospective comparative randomized study was carried out on 40 patients suffering from contracted sockets. They were randomly enrolled into 2 groups. Group A included 20 patients who had a surgery to treat contracted socket without augmentation with MMC. Group B patients had an MMC-augmented repair for the contracted socket. Patients were followed up over a period of 12 months for changes in inferior fornix (IF) depth and ability to retain the ocular prosthesis. At the end of the follow-up period, postoperative IF depth was significantly deeper in group B (with MMC) than in group A (without MMC). As well, 75% of the patients in group B could maintain the prosthetic eye shell, whereas only 35% of group A could maintain the prosthesis. This study shows that using intraoperative MMC (0.2 mg/mL) in contracted socket reconstruction plays a significant role in maintaining prosthetic eye. To the best of our knowledge, this study is the first to use MMC on a relatively large scale of patients with contracted socket. However, the follow-up period was relatively short and further work is required to verify the effect of MMC on a longer follow-up period.
2014-07-01
voluminous threat environment. Today we regularly construct seamless encrypted communications between machines through SSL or other TLS . These do not...return to the web application and the user, As a prerequisite to end-to-end communication an SSL , or other suitable TLS is set up between each of the...an TLS connection is established between the requestor and the service provider, within which a WS-Security package will be sent to the service
Research on infrared ship detection method in sea-sky background
NASA Astrophysics Data System (ADS)
Tang, Da; Sun, Gang; Wang, Ding-he; Niu, Zhao-dong; Chen, Zeng-ping
2013-09-01
An approach to infrared ship detection based on sea-sky-line(SSL) detection, ROI extraction and feature recognition is proposed in this paper. Firstly, considering that far ships are expected to be adjacent to the SSL, SSL is detected to find potential target areas. Radon transform is performed on gradient image to choose candidate SSLs, and detection result is given by fuzzy synthetic evaluation values. Secondly, in view of recognizable condition that there should be enough differences between target and background in infrared image, two gradient masks have been created and improved as practical guidelines in eliminating false alarm. Thirdly, extract ROI near the SSL by using multi-grade segmentation and fusion method after image sharpening, and unsuitable candidates are screened out according to the gradient masks and ROI shape. Finally, we segment the rest of ROIs by two-stage modified OTSU, and calculate target confidence as a standard measuring the facticity of target. Compared with other ship detection methods, proposed method is suitable for bipolar targets, which offers a good practicability and accuracy, and achieves a satisfying detection speed. Detection experiments with 200 thousand frames show that the proposed method is widely applicable, powerful in resistance to interferences and noises with a detection rate of above 95%, which satisfies the engineering needs commendably.
Complete solid state lighting (SSL) line at CEA LETI
NASA Astrophysics Data System (ADS)
Robin, I. C.; Ferret, P.; Dussaigne, A.; Bougerol, C.; Salomon, D.; Chen, X. J.; Charles, M.; Tchoulfian, P.; Gasse, A.; Lagrange, A.; Consonni, M.; Bono, H.; Levy, F.; Desieres, Y.; Aitmani, A.; Makram-Matta, S.; Bialic, E.; Gorrochategui, P.; Mendizabal, L.
2014-09-01
With a long experience in optoelectronics, CEA-LETI has focused on Light Emitting Diode (LED) lighting since 2006. Today, all the technical challenges in the implementation of GaN LED based solid state lighting (SSL) are addressed at CEA-LETI who is now an RandD player throughout the entire value chain of LED lighting. The SSL Line at CEA-LETI first deals with the simulation of the active structures and LED devices. Then the growth is addressed in particular 2D growth on 200 mm silicon substrates. Then, technological steps are developed for the fabrication of LED dies with innovative architectures. For instance, Versatile LED Array Devices are currently being developed with a dedicated μLED technology. The objective in this case is to achieve monolithical LED arrays reported and interconnected through a silicon submount. In addition to the required bonding and 3D integration technologies, new solutions for LED chip packaging, thermal management of LED lamps and luminaires are also addressed. LETI is also active in Smart Lighting concepts which offer the possibility of new application fields for SSL technologies. An example is the recent development at CEA LETI of Visible Light Communication Technology also called LiFi. With this technology, we demonstrated a transmission rate up to 10 Mb/s and real time HD-Video transmission.
46 CFR 56.30-5 - Welded joints.
Code of Federal Regulations, 2010 CFR
2010-10-01
... systems and should be checked when designing for these systems. (c) Socket welds (Modifies 127.3.3A.). (1) Each socket weld must conform to ASME B16.11 (incorporated by reference; see 46 CFR 56.01-2), to... approximately one-sixteenth inch between the end of the pipe and the bottom of the socket must be provided...
46 CFR 56.30-5 - Welded joints.
Code of Federal Regulations, 2012 CFR
2012-10-01
... systems and should be checked when designing for these systems. (c) Socket welds (Modifies 127.3.3A.). (1) Each socket weld must conform to ASME B16.11 (incorporated by reference; see 46 CFR 56.01-2), to... approximately one-sixteenth inch between the end of the pipe and the bottom of the socket must be provided...
46 CFR 56.30-5 - Welded joints.
Code of Federal Regulations, 2011 CFR
2011-10-01
... systems and should be checked when designing for these systems. (c) Socket welds (Modifies 127.3.3A.). (1) Each socket weld must conform to ASME B16.11 (incorporated by reference; see 46 CFR 56.01-2), to... approximately one-sixteenth inch between the end of the pipe and the bottom of the socket must be provided...
46 CFR 56.30-5 - Welded joints.
Code of Federal Regulations, 2013 CFR
2013-10-01
... systems and should be checked when designing for these systems. (c) Socket welds (Modifies 127.3.3A.). (1) Each socket weld must conform to ASME B16.11 (incorporated by reference; see 46 CFR 56.01-2), to... approximately one-sixteenth inch between the end of the pipe and the bottom of the socket must be provided...
21 CFR 888.3510 - Knee joint femorotibial metal/polymer constrained cemented prosthesis.
Code of Federal Regulations, 2012 CFR
2012-04-01
...-and-socket joint located between a stemmed femoral and a stemmed tibial component and a runner and track joint between each pair of femoral and tibial condyles. The ball-and-socket joint is composed of a...-molybdenum. The ball of the tibial component is held within the socket of the femoral component by the...
46 CFR 56.30-5 - Welded joints.
Code of Federal Regulations, 2014 CFR
2014-10-01
... systems and should be checked when designing for these systems. (c) Socket welds (Modifies 127.3.3A.). (1) Each socket weld must conform to ASME B16.11 (incorporated by reference; see 46 CFR 56.01-2), to... approximately one-sixteenth inch between the end of the pipe and the bottom of the socket must be provided...
21 CFR 888.3510 - Knee joint femorotibial metal/polymer constrained cemented prosthesis.
Code of Federal Regulations, 2011 CFR
2011-04-01
...-and-socket joint located between a stemmed femoral and a stemmed tibial component and a runner and track joint between each pair of femoral and tibial condyles. The ball-and-socket joint is composed of a...-molybdenum. The ball of the tibial component is held within the socket of the femoral component by the...
Preliminary evaluation of hermetic JT/LJT/R P connector socket contact design
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baca, J.R.F.
1991-10-01
This report presents a precursory examination of a number of issues pertaining to socket contacts in hermetic connectors. The principal issues addressed are high-contact resistance and contact chatter (circuit discontinuities). Efforts examining the characteristics of the existing socket contact design, the possibility of connector/contact rework, quick-fix solutions, and contact redesigns are summarized.
21 CFR 888.3510 - Knee joint femorotibial metal/polymer constrained cemented prosthesis.
Code of Federal Regulations, 2013 CFR
2013-04-01
...-and-socket joint located between a stemmed femoral and a stemmed tibial component and a runner and track joint between each pair of femoral and tibial condyles. The ball-and-socket joint is composed of a...-molybdenum. The ball of the tibial component is held within the socket of the femoral component by the...
21 CFR 888.3510 - Knee joint femorotibial metal/polymer constrained cemented prosthesis.
Code of Federal Regulations, 2014 CFR
2014-04-01
...-and-socket joint located between a stemmed femoral and a stemmed tibial component and a runner and track joint between each pair of femoral and tibial condyles. The ball-and-socket joint is composed of a...-molybdenum. The ball of the tibial component is held within the socket of the femoral component by the...
Prevention and treatment of dry socket.
Dodson, Tom
2013-03-01
Cochrane Oral Health Group Trials Register, Cochrane Central Register of Controlled Trials (CENTRAL), Medline and Embase databases were searched together with reference lists of identified articles. Topic experts and organisations were also contacted. Only randomised controlled trials were considered and there were no restrictions regarding language or date of publication. Data abstraction and risk of bias assessment were conducted in duplicate and Cochrane statistical guidelines were followed. The GRADE tool was used to assess the quality of the body of evidence. Twenty-one trials with 2570 participants were included. Eighteen trials (2376 participants) related to prevention and three to treatment (194 participants). Six studies were at high risk of bias, 14 of unclear risk and one study at low risk. There was moderate evidence (four trials, 750 participants) that chlorhexidine mouthrinses (0.12% and 0.2% concentrations) both before and after extraction(s) prevented approximately 42% of dry socket(s) with a RR of 0.58 (95% CI 0.43 to 0.78; P < 0.001). The number of patients needed to be treated (0.12% and 0.2%) with chlorhexidine rinse to prevent one patient having dry socket (NNT) was 232 (95% CI 176 to 417), 47 (95% CI 35 to 84) and 8 (95% CI 6 to 14) at prevalences of dry socket of 1%, 5% and 30% respectively. Thee was moderate evidence (two trials, in 133 participants) that placing chlorhexidine gel (0.2%) after extractions prevented approximately 58% of dry socket(s) with a RR of 0.42 (95% CI 0.21 to 0.87; P = 0.02) with NNT of 173 (95% CI 127 to 770), 35 (95% CI 25 to 154) and 6 (95% CI 5 to 26) at prevalences of dry socket of 1%, 5% and 30% respectively. There was insufficient evidence to determine the effects of other intrasocket preventive interventions or interventions to treat dry socket. There is some evidence that rinsing with chlorhexidine (0.12% and 0.2%) or placing chlorhexidine gel (0.2%) in the sockets of extracted teeth, provides a benefit in preventing dry socket. There was insufficient evidence to determine the effects of the other 10 preventative interventions each evaluated in single studies. There was insufficient evidence to determine the effects of any of the interventions to treat dry socket. The present review found some evidence for the association of minor adverse reactions with use of 0.12%, 0.2% and 2% chlorhexidine mouthrinses, though most studies were not designed to detect the presence of hypersensitivity reactions to mouthwash as part of the study protocol. No adverse events were reported in relation to the use of 0.2% chlorhexidine gel placed directly into a socket (though previous allergy to chlorhexidine was an exclusion criterion in these trials). In view of recent reports in the UK of two cases of serious adverse events associated with irrigation of dry socket with chlorhexidine mouthrinse, it is recommended that all members of the dental team prescribing chlorhexidine products are aware of the potential for both minor and serious adverse side effects. It is beyond the scope of this review to describe and detail The Cochrane Collaboration. The reader can seek out more information at http://www.cochrane.org/. In brief, a systematic review supported and published by the Cochrane group represents the gold standard to support clinical decision-making.
Jee, Jeong-Hyun; Lee, Wan; Lee, Byung Do
2010-08-01
Many dental patients take bisphosphonates to reduce the risk of hip and vertebral fractures. In vivo micro-computed tomography (micro-CT) was used to examine the longitudinal inhibitory effect of alendronate on the healing of extraction sockets in ovariectomized rats. Twenty 5-week-old Sprague-Dawley rats were assigned randomly to 1 of 3 groups: sham-operated (n = 5), and 2 ovariectomized (OVX) groups: saline treated (0.1 mL/100 g/d, n = 7) and alendronate treated (1 mg/kg/d, n = 8). Before micro-CT scanning, the left maxillary first molars of the rats were extracted. In vivo micro-CT (spatial resolution 50 x 50 mum) of the jaw was performed at baseline and at 2-week intervals for 6 weeks. Alveolar-bone radiographic densities and dimensions were analyzed with repeated measures analysis of variance. The bony healing patterns of the extraction sockets were also evaluated in each group. The radiographic socket densities of the sham-treated and OVX-alendronate groups significantly increased during the first 4 weeks after extraction (P < .05). At 2 weeks, the radiographic densities of the sockets in the OVX-saline group increased, but the increase was significantly lower than for the other groups at 4 weeks (P < .05). Newly formed bone was identified in the extraction sockets in all groups 2 to 6 weeks after extraction. There was a significant loss of alveolar ridge height at the second week postextraction compared with baseline, and at the fourth week compared with the second week (P < .05) except in the alendronate group. Alendronate appears to promote the healing of extraction sockets in estrogen-deficient rats and helps resist the loss of alveolar bone adjacent to extraction sockets. Copyright 2010 Mosby, Inc. All rights reserved.
Kobayashi, Toshiki; Orendurff, Michael S; Arabian, Adam K; Rosenbaum-Chou, Teri G; Boone, David A
2014-04-11
The alignment of a lower limb prosthesis affects the way load is transferred to the residual limb through the socket, and this load is critically important for the comfort and function of the prosthesis. Both magnitude and duration of the moment are important factors that may affect the residual limb health. Moment impulse is a well-accepted measurement that incorporates both factors via moment-time integrals. The aim of this study was to investigate the effect of alignment changes on the socket reaction moment impulse in transtibial prostheses. Ten amputees with transtibial prostheses participated in this study. The socket reaction moment impulse was measured at a self-selected walking speed using a Smart Pyramid in 25 alignment conditions, including a nominal alignment (clinically aligned by a prosthetist), as well as angle malalignments of 2°, 4° and 6° (abduction, adduction, extension and flexion) and translation malalignments of 5 mm, 10 mm and 15 mm (lateral, medial, anterior and posterior). The socket reaction moment impulse of the nominal alignment was compared for each condition. The relationship between the alignment and the socket reaction moment impulse was clearly observed in the coronal angle, coronal translation and sagittal translation alignment changes. However, this relationship was not evident in the sagittal angle alignment changes. The results of this study suggested that the socket reaction moment impulse could potentially serve as a valuable parameter to assist the alignment tuning process for transtibial prostheses. Further study is needed to investigate the influence of the socket reaction moment impulse on the residual limb health. Copyright © 2014 Elsevier Ltd. All rights reserved.
Kobayashi, Toshiki; Arabian, Adam K; Orendurff, Michael S; Rosenbaum-Chou, Teri G; Boone, David A
2014-01-01
Energy storage and return feet are designed for active amputees. However, little is known about the socket reaction moments in transtibial prostheses with energy storage and return feet. The aim of this study was to investigate the effect of alignment changes on the socket reaction moments during gait while using the energy storage and return feet. A Smart Pyramid™ was used to measure the socket reaction moments in 10 subjects with transtibial prostheses while walking under 25 alignment conditions, including a nominal alignment (as defined by conventional clinical methods), as well as angle malalignments of 2°, 4° and 6° (flexion, extension, abduction, and adduction) and translation malalignments of 5mm, 10mm and 15mm (anterior, posterior, lateral, and medial) referenced from the nominal alignment. The socket reaction moments of the nominal alignment were compared with each malalignment. Both coronal and sagittal alignment changes demonstrated systematic effects on the socket reaction moments. In the sagittal plane, angle and translation alignment changes demonstrated significant differences (P<0.05) in the minimum moment, the moment at 45% of stance and the maximum moment for some comparisons. In the coronal plane, angle and translation alignment changes demonstrated significant differences (P<0.05) in the moment at 30% and 75% of stance for all comparisons. The alignment may have systematic effects on the socket reaction moments in transtibial prostheses with energy storage and return feet. The socket reaction moments could potentially be a useful biomechanical parameter to evaluate the alignment of the transtibial prostheses. Copyright © 2013 Elsevier Ltd. All rights reserved.
Connecting to the Internet Securely; Protecting Home Networks CIAC-2324
DOE Office of Scientific and Technical Information (OSTI.GOV)
Orvis, W J; Krystosek, P; Smith, J
2002-11-27
With more and more people working at home and connecting to company networks via the Internet, the risk to company networks to intrusion and theft of sensitive information is growing. Working from home has many positive advantages for both the home worker and the company they work for. However, as companies encourage people to work from home, they need to start considering the interaction of the employee's home network and the company network he connects to. This paper discusses problems and solutions related to protection of home computers from attacks on those computers via the network connection. It does notmore » consider protection of those systems from people who have physical access to the computers nor does it consider company laptops taken on-the-road. Home networks are often targeted by intruders because they are plentiful and they are usually not well secured. While companies have departments of professionals to maintain and secure their networks, home networks are maintained by the employee who may be less knowledgeable about network security matters. The biggest problems with home networks are that: Home networks are not designed to be secure and may use technologies (wireless) that are not secure; The operating systems are not secured when they are installed; The operating systems and applications are not maintained (for security considerations) after they are installed; and The networks are often used for other activities that put them at risk for being compromised. Home networks that are going to be connected to company networks need to be cooperatively secured by the employee and the company so they do not open up the company network to intruders. Securing home networks involves many of the same operations as securing a company network: Patch and maintain systems; Securely configure systems; Eliminate unneeded services; Protect remote logins; Use good passwords; Use current antivirus software; and Moderate your Internet usage habits. Most of these items do not take a lot of work, but require an awareness of the risks involved in not doing them or doing them incorrectly. The security of home networks and communications with company networks can be significantly improved by adding an appropriate software or hardware firewall to the home network and using a protected protocol such as Secure Sockets Layer (SSL), a Virtual Private Network (VPN), or Secure Shell (SSH) for connecting to the company network.« less
Cooled electronic system with thermal spreaders coupling electronics cards to cold rails
Chainer, Timothy J; Gaynes, Michael A; Graybill, David P; Iyengar, Madhusudan K; Kamath, Vinod; Kochuparambil, Bejoy J; Schmidt, Roger R; Schultz, Mark D; Simco, Daniel P; Steinke, Mark E
2013-07-23
Liquid-cooled electronic systems are provided which include an electronic assembly having an electronics card and a socket with a latch at one end. The latch facilitates securing of the card within the socket or removal of the card from the socket. A liquid-cooled cold rail is disposed at the one end of the socket, and a thermal spreader couples the electronics card to the cold rail. The thermal spreader includes first and second thermal transfer plates coupled to first and second surfaces on opposite sides of the card, and thermally conductive extensions extending from end edges of the plates, which couple the respective transfer plates to the liquid-cooled cold rail. The thermally conductive extensions are disposed to the sides of the latch, and the card is securable within or removable from the socket using the latch without removing the cold rail or the thermal spreader.
Mourits, Daphne L; Remmers, Jelmer S; Tan, Stevie H; Moll, Annette C; Hartong, Dyonne T
2018-04-03
To introduce a novel technique to design individually customized conformers for postenucleation sockets with dermis fat implants. We use a 3-dimensional scan of the frontal face/orbit and eyelid contour to design an individualized conformer. This polymethylmetacrylate printed conformer is adapted to patients' socket, palpebral fissures, horizontal eyelid aperture, curvature of the eyelids, and mean diameter of patients' contralateral eye. Sutures through holes in the inferior part of the conformer and in the extension can be placed to fixate the conformer and anchor fornix deepening sutures. A correct fitting conformer can be printed and attached to the socket and eyelids. The shape of this conformer can be used subsequently postsurgically to design the ocular prosthesis. Presurgical planning is important to anticipate for a functional socket to adequately fit an artificial eye. The presented technique using 3-dimensional imaging, designing, and printing promises to prevent conformer extrusion and forniceal shortening.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Higuchi, Makoto; Nakagawa, Akira; Chujo, Noriyuki
1996-12-01
Rotating bending fatigue tests were conducted on socket welded joints of a nominal diameter 20 mm, and effects of root defect and other various factors, including post-weld heat treatment (PWHT), pipe wall thickness, and socket wall thickness, were investigated. The socket joints exhibited, in the rotating bending fatigue mode, fatigue strengths that were markedly lower than the same 20 mm diameter joints in four-point bending fatigue. Also, where the latter specimens failed always at the toe, root-failures occurred in rotating bending fatigue. When PWHT`d, however, the fatigue strength showed a remarkable improvement, while the failure site reverted to toe. Thickermore » pipe walls and socket walls gave rise to higher fatigue strength. A formula relating the size of root defects to the fatigue strength reduction has been proposed.« less
Conservative Socket Regeneration with Buccal Wall Defect Using Guided Tissue.
Al-Juboori, Mohammed Jasim
2016-01-01
Progressive alveolar bone resorption after tooth extraction may lead to surgical and prosthetic-driven difficulties, especially when deciding to use a dental implant to replace the extracted tooth. This case report discusses an irreparable lower left second premolar tooth with a periodontal lesion on the buccal side. A preservative tooth extraction was performed. Then, the socket was grafted with bovine bone, a collagen membrane was placed between the buccal bone and the attached gingiva, covering the bone dehiscence buccally, and the socket without a flap was raised. After a 6-month healing period, there was minimal socket width resorption and a shallow buccal vestibule. The implant was placed with high primary stability and sufficient buccal plate thickness. In conclusion, this guided tissue regeneration technique can minimize alveolar bone resorption in a socket with buccal dehiscence, but technical difficulties and shallowing of the buccal vestibule still exist.
Aggarwal, Himanshi; Singh, Saumyendra V; Kumar, Pradeep; Kumar Singh, Arun
2015-06-01
One of the most common tumors of the eye diagnosed in childhood is retinoblastoma, which mandates enucleation with adjunctive chemotherapy and radiotherapy to save the patient's life. The most common late enucleation complication is post-enucleation socket syndrome (PESS), which poses a management dilemma for the prosthodontist and surgeon, along with being a major esthetic concern for the patient. The reconstruction of such sockets is complex. The purpose of this clinical report is to describe the rehabilitation of such a pediatric patient with severe PESS. The patient was successfully rehabilitated by presurgical conformer therapy, socket reconstruction surgery with non-meshed intermediate split thickness skin graft (STSG)/Blair-Brown graft, and postsurgical conformer stent. This was followed by fabrication of a custom ocular prosthesis, to achieve favorable functional, physical, and psychological effects. © 2014 by the American College of Prosthodontists.
8-year survivorship analysis and subjective results of 687 primary Balgrist hip sockets.
Echtler, B; Jacob, H A; Houweling, M; Hersche, O
1999-09-01
The Balgrist hip socket consists of an outer split ring in the form of a truncated cone, made of titanium, which is expanded by a tapered HDPE insert during implantation, thus ensuring firm primary press-fit and the possibility of retightening in the postoperative remodelling phase. Between November 1987 and October 1996, 687 primary Balgrist hip sockets were implanted in 555 patients. Five hundred and thirty-seven patients were investigated. Of these patients, 71.1% never had pain in the operated hip, 88.1% had no problems putting on their shoes, 76.2% were able to walk one or more hours. Furthermore, 91.7% are very or mostly content with the postoperative result. Nineteen hip sockets had to be revised until April 1997. With a 92.1% Kaplan-Meier survivorship rate after 8 years the Balgrist hip socket ranks among the most successful noncemented acetabular components.
Simpson, G; Fisher, C; Wright, D K
2001-01-01
Continuing earlier studies into the relationship between the residual limb, liner and socket in transtibial amputees, we describe a geometrically accurate non-linear model simulating the donning of a liner and then a socket. The socket is rigid and rectified and the liner is a polyurethane geltype which is accurately described using non-linear (Mooney-Rivlin) material properties. The soft tissue of the residual limb is modelled as homogeneous, non-linear and hyperelastic and the bone structure within the residual limb is taken as rigid. The work gives an indication of how the stress induced by the process of donning the rigid socket is redistributed by the liner. Ultimately we hope to understand how the liner design might be modified to reduce discomfort. The ANSYS finite element code, version 5.6 is used.
76 FR 56279 - Airworthiness Directives; Airbus Model A318, A319, A320, and A321 Series Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-13
... to socket arcing at the Integrated Drive Generator (IDG) feeder cable pylon/nacelle interface connector. The fretting corrosion phenomenon was identified to be the root cause of the pin to socket arcing... products. The MCAI states: In service experience has shown a number of events of pin to socket arcing at...
Code of Federal Regulations, 2010 CFR
2010-01-01
... with ceiling fan light kits that have medium screw base sockets shall conform to the requirements... testing pin-based fluorescent lamps packaged with ceiling fan light kits that have pin-based sockets shall... base sockets, measure the efficacy, expressed in lumens per watt, in accordance with the test...
NASA Technical Reports Server (NTRS)
Aperlo, P. J. A.; Buck, P. A.; Weldon, V. A.
1981-01-01
In ball and socket joint where electrical insulator such as polytetrafluoroethylene is used as line to minimize friction, good electrical contact across joint may be needed for lightning protection or to prevent static-charge build-up. Electrical contact is maintained by ring of spring-loaded fingers mounted in socket. It may be useful in industry for cranes, trailers, and other applications requiring ball and socket joint.
Carbon nanotubes functionalized with sodium hyaluronate restore bone repair in diabetic rat sockets.
Sá, M A; Andrade, V B; Mendes, R M; Caliari, M V; Ladeira, L O; Silva, E E; Silva, G A B; Corrêa-Júnior, J D; Ferreira, A J
2013-07-01
We evaluated the effects of sodium hyaluronate (HY) and carbon nanotubes functionalized with HY (HY-CNT) on bone repair in the tooth sockets of diabetic rats. Diabetes was induced by streptozotocin (50 mg kg(-1) i.v.), and the sockets were divided into normal control, diabetic control, diabetic treated with HY (1%), and diabetic treated with HY-CNT (100 μg ml(-1)) groups. The sockets were analyzed according to the percentage of bone formation and the number of cell nuclei. The percentage of bone trabeculae was lower in diabetic control animals (11.16 ± 5.10% vs 41.92 ± 6.34% in normal animals) after 14 days. Treating diabetic animals with HY or HY-CNT significantly increased the percentage of neoformed trabeculae (HY: 29.43 ± 3.29%; HY-CNT: 36.90 ± 3.07%). Moreover, the sockets of diabetic animals had an increased number of cell nuclei and HY or HY-CNT reduced this parameter. Our results indicate that HY and HY-CNT restore bone repair in the tooth sockets of diabetic rats, suggesting that these biomaterials are potential adjuvant therapies for the management of diabetes. © 2012 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Bone implant sockets made using three different procedures: a stability study in dogs
Campo, Julián
2012-01-01
Objective: This study compared the effects of three different methods of preparing bone implant sockets (drilling, osteotomes, and piezoelectric device) on osseointegration using resonance frequency analysis (RFA). Study Design: An experimental prospective study was designed. Material and Methods: Ten adult beagle dogs were studied. After 5 weeks, 23 out of 28 initially placed implants in the iliac crest were evaluated, comparing these three different procedures of bone implant socket. Student’s t-test (paired, two-tailed) was used to reveal differences among the three groups at each time point (SPSS 16.0, IL, USA). Results: After a 5-week healing period, the implants placed in sockets that were made using an osteotome or piezoelectric device were slightly more stable than those made by drilling. Reduced mechanical and heat injury to the bone is beneficial for maintaining and improving stability during the critical early healing period. Conclusion: Using RFA, there was evidence of a slight increase in implant stability in the iliac crest after 5 weeks of healing when the implant socket was made using a piezoelectric device or expansion procedure as compare with the drilling method. Key words:Bone implant sockets, drilling, osteotomes, piezoelectric, resonance frequency analysis, stability. PMID:24558558
Alveolar socket healing: what can we learn?
Araújo, Mauricio G; Silva, Cléverson O; Misawa, Mônica; Sukekava, Flavia
2015-06-01
Tooth extraction induces a series of complex and integrated local changes within the investing hard and soft tissues. These local alterations arise in order to close the socket wound and to restore tissue homeostasis, and are referred to as '"socket healing". The aims of the present report were twofold: first, to describe the socket-healing process; and, second, to discuss what can be learned from the temporal sequence of healing events, in order to improve treatment outcomes. The socket-healing process may be divided into three sequential, and frequently overlapping, phases: inflammatory; proliferative; and modeling/remodeling. Several clinical and experimental studies have demonstrated that the socket-healing process promotes up to 50% reduction of the original ridge width, greater bone resorption at the buccal aspect than at the lingual/palatal counterpart and a larger amount of alveolar bone reduction in the molar region. In conclusion, tooth extraction, once a simple and straightforward surgical procedure, should be performed in the knowledge that ridge reduction will follow and that further clinical steps should be considered to compensate for this, when considering future options for tooth replacement. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Piezoelectric Bimorphs' Characteristics as In-Socket Sensors for Transfemoral Amputees
El-Sayed, Amr M.; Hamzaid, Nur Azah; Osman, Noor Azuan Abu
2014-01-01
Alternative sensory systems for the development of prosthetic knees are being increasingly highlighted nowadays, due to the rapid advancements in the field of lower limb prosthetics. This study presents the use of piezoelectric bimorphs as in-socket sensors for transfemoral amputees. An Instron machine was used in the calibration procedure and the corresponding output data were further analyzed to determine the static and dynamic characteristics of the piezoelectric bimorph. The piezoelectric bimorph showed appropriate static operating range, repeatability, hysteresis, and frequency response for application in lower prosthesis, with a force range of 0–100 N. To further validate this finding, an experiment was conducted with a single transfemoral amputee subject to measure the stump/socket pressure using the piezoelectric bimorph embedded inside the socket. The results showed that a maximum interface pressure of about 27 kPa occurred at the anterior proximal site compared to the anterior distal and posterior sites, consistent with values published in other studies. This paper highlighted the capacity of piezoelectric bimorphs to perform as in-socket sensors for transfemoral amputees. However, further experiments are recommended to be conducted with different amputees with different socket types. PMID:25513823
Metalorganic chemical vapor deposition of gallium nitride on sacrificial substrates
NASA Astrophysics Data System (ADS)
Fenwick, William Edward
GaN-based light emitting diodes (LEDs) face several challenges if the technology is to continue to make a significant impact in general illumination, and on technology that has become known as solid state lighting (SSL). Two of the most pressing challenges for the continued penetration of SSL into traditional lighting applications are efficacy and total lumens from the device, and their related cost. The development of alternative substrate technologies is a promising avenue toward addressing both of these challenges, as both GaN-based device technology and the associated metalorganic chemical vapor deposition (MOCVD) technology are already relatively mature technologies with a well-understood cost base. Zinc oxide (ZnO) and silicon (Si) are among the most promising alternative substrates for GaN epitaxy. These substrates offer the ability to access both higher efficacy and lumen devices (ZnO) at a much reduced cost. This work focuses on the development of MOCVD growth processes to yield high quality GaN-based materials and devices on both ZnO and Si. ZnO is a promising substrate for growth of low defect-density GaN because of its similar lattice constant and thermal expansion coefficient. The major hurdles for GaN growth on ZnO are the instability of the substrate in a hydrogen atmosphere, which is typical of nitride growth conditions, and the inter-diffusion of zinc and oxygen from the substrate into the GaN-based epitaxial layer. A process was developed for the MOCVD growth of GaN and InxGa 1-xN on ZnO that attempted to address these issues. The structural and optical properties of these films were studied using various techniques. X-ray diffraction (XRD) showed the growth of wurtzite GaN on ZnO, and room-temperature photoluminescence (RT-PL) showed near band-edge luminescence from the GaN and InxGa1-xN layers. However, high zinc and oxygen concentrations due to interdiffusion near the ZnO substrate remained an issue; therefore, the diffusion of zinc and oxygen into the subsequent GaN layer was studied in more detail. Several approaches were investigated---for example, transition layers such as Al2O3 and Al xGa1-xN/GaN---to minimize diffusion of these impurities into the GaN layer. Silicon, due to its prevalence, is the most promising material for the development of an inexpensive, large-area substrate technology. The challenge in MOCVD growth of GaN on Si is the tensile strain induced by the lattice and thermal mismatch between GaN and Si and the formation of anti-phase boundaries. Typical approaches to solve these problems involve complicated and multiple buffer layer structures, which lead to relatively slow growth rates. In this work, a thin atomic layer deposition (ALD)-grown Al2O3 interlayer was employed to relieve strain and increase material quality while also simplifying the growth process. While some residual strain was still observed in the GaN material by XRD and PL, the use of this oxide interlayer leads to an improvement in thin film quality as seen by a reduction in both crack density (<1 mm-2) on ALD-Al2O3/Si) and screw dislocation density (from 3x109cm-2 on bare Si to 2x108cm-2 on ALD-Al 2O3/Si) in the GaN films. A side-by-side comparison of GaN-based multiple quantum well LEDs grown on sapphire and on Al2O3/Si shows similar performance characteristic for both device structures. A redshift in peak emission wavelength was also observed on silicon compared to sapphire, and this is attributed to higher indium content due to the slight tensile strain in the layers on silicon. IQE of the devices on silicon is ˜32% as measured by LT-PL, compared to ˜37% on sapphire, but this difference can be assigned to the difference in indium compositions. These results show a great promise toward an inexpensive, large-area, silicon-based substrate technology for MOCVD growth of the next generation of GaN-based optoelectronic devices for SSL and other applications.
Resource Public Key Infrastructure Extension
2012-01-01
tests for checking compliance with the RFC 3779 extensions that are used in the RPKI. These tests also were used to identify an error in the OPENSSL ...rsync, OpenSSL , Cryptlib, and MySQL/ODBC. We assume that the adversaries can exploit any publicly known vulnerability in this software. • Server...NULL, set FLAG_NOCHAIN in Ctemp, defer verification. T = P Use OpenSSL to verify certificate chain S using trust anchor T, checking signature and
Process Approach to Determining Quality Inspection Deployment Product Overview
2015-05-07
Kevin Craig SSL Ken Dodson SSL Frank Fieldson Harris Edward Gaitley The Aerospace Corporation Anthony Gritsavage NASA Michael Kelly NASA Neil...finkrich@nro.mil Marvin LeBlanc NOAA Marvin.LeBlanc@noaa.gov Robert Adkisson Boeing robert.w.adkisson@boeing.com Mark Baldwin Raytheon Mark.L.Baldwin...Silvia.Bouchard@ngc.com Mark Braun Raytheon mark.j.braun@raytheon.com Marvin Candee Lockheed Martin marvin.candee@lmco.com Larry Capots Lockheed Martin
2012-11-01
21010-5424 8. PERFORMING ORGANIZATION REPORT NUMBER ECBC-TR-981 9. SPONSORING / MONITORING AGENCY NAME(S) AND ADDRESS(ES) Strategic Environmental ...triazine (RDX) to the potworm Enchytraeus crypticus using the Enchytraeid Reproduction Test (ISO 16387:2004). Studies were designed to identify and...clay loam soils. Toxicity benchmarks established in TSL and SSL will be submitted to the U.S. Environmental Protection Agency Eco-SSL Workgroup for
Van Steertegem, Bénédicte; Pareyt, Bram; Brijs, Kristof; Delcour, Jan A
2013-12-15
The impact of differences in dough transient gluten network on gluten cross-linking during baking is insufficiently understood. We varied dough mixing times and/or added sodium stearoyl lactylate (SSL; 1.0% on flour dry matter basis) to the recipe and studied the effect on subsequent gluten polymerization during heating. The level of proteins extractable in sodium dodecyl sulfate containing media was fitted using first order kinetics. The extent and rate of gluten polymerization were lower when mixing for 8 min than when mixing for 2 min. This effect was even more outspoken in the presence of SSL. The present observations were explained as resulting from less gliadin incorporation in the polymer gluten network and from interaction of SSL with the gluten proteins. Finally, a higher degree of gluten polymerization during baking increased the firmness of the baked products. Copyright © 2013 Elsevier Ltd. All rights reserved.
López-Crespo, Ginesa; Daza, María Teresa; Méndez-López, Magdalena
2012-01-01
Although visual functions have been proposed to be enhanced in deaf individuals, empirical studies have not yet established clear evidence on this issue. The present study aimed to determine whether deaf children with diverse communication modes had superior visual memory and whether their performance was improved by the use of differential outcomes. Severely or profoundly deaf children who employed spoken Spanish, Spanish Sign Language (SSL), and both spoken Spanish and SSL modes of communication were tested in a delayed matching-to-sample task for visual working memory assessment. Hearing controls were used to compare performance. Participants were tested in two conditions, differential outcome and non-differential outcome conditions. Deaf groups with either oral or SSL modes of communication completed the task with less accuracy than bilingual and control hearing children. In addition, the performances of all groups improved through the use of differential outcomes. Copyright © 2011 Elsevier Ltd. All rights reserved.
Bi, Xiaoping; Fan, Xianqun; Zhou, Huifang; Shi, Wodong; Xiao, Caiwen; Lin, Min; Li, Zhenkang
2011-05-01
Retinoblastoma is a common malignant intraocular tumor in childhood, and most patients require enucleation or exenteration even with irradiation. Severe anophthalmic orbits and atresic eye sockets are not rare. We conducted a retrospective study to evaluate the results of surgical management of reconstruction of severe anophthalmic orbits and atresic eye sockets with vascular anastomosed free dorsalis pedis flap transplantation. There were 5 patients (5 eyes) who underwent reconstructive surgery of severe anophthalmic orbits and atresic eye sockets after enucleation and irradiation of retinoblastoma in our hospital during the 3 years. All patients had enucleation and irradiation immediately after the retinoblastoma was diagnosed and had never worn artificial eyes because of the atresic eye sockets. Vascular anastomosed free dorsalis pedis flaps, whose dimensions were typically 6.5 × 5.5 cm(2), were transplanted to reconstruct the severe anophthalmic orbits and atresic eye sockets. The donor sites were covered by free abdominal skin flaps. All the vascular anastomosed free dorsalis pedis flaps were valid after more than 6 months of follow-up. And then all the 5 patients underwent secondary autogenous dermal fat implantation to augment the supraorbital area depression. After the 2-stage reconstruction surgery, the dimensions of the eye sockets were adequate, and all patients were able to wear their prosthesis and had a satisfactory cosmetic result. Implantation of alloplastic materials is not recommended because of insufficient blood supply of the irradiated orbital area.
Evaluation of osteoblastic activity in extraction sockets treated with platelet-rich fibrin.
Baslarli, Ozgur; Tumer, Celal; Ugur, Omer; Vatankulu, Betul
2015-01-01
The aim of this study was to determine whether the use of platelet rich fibrin (PRF) improved the healing of extraction sockets. A total of 20 patients with bilateral soft tissue impacted mandibular third molars were included in this study. The left and right third molars were extracted during the same session. Subsequently, the PRF membrane was randomly administered to one of the extraction sockets, whereas the contralateral sockets were left without treatment. On postoperative 30. and 90. days, panoramic images and bone scintigrams were taken to evaluate the bone healing between PRF-treated and non-PRF-treated sockets. Also, periodontal evaluation was performed in the same control sessions. Dependent group t test for paired samples was used for statistical analysis. The average increase in technetium-99m methylene diphosphonate uptake as an indication of enhanced bone healing did not differ significantly between PRF-treated and non-PRF-treated sockets 30 and 90 days postoperatively. Radio-opacity that can show the bone healing on panoramic images were measured by Image J programme and they did not differ significantly. Also periodontal values did not differ significantly. PRF might not lead to enhanced bone healing in impacted mandibular third molar extraction sockets 30 and 90 days after surgery. It is thought that PRF has the potential characteristics of an autologous fibrin matrix and can accelerate the healing. To better understand the effects of PRF on healing, further research is warranted with larger sample sizes.
Alveolar socket preservation with demineralised bovine bone mineral and a collagen matrix
2017-01-01
Purpose The aim of the present study was to evaluate the healing of post-extraction sockets following alveolar ridge preservation clinically, radiologically, and histologically. Methods Overall, 7 extraction sockets in 7 patients were grafted with demineralised bovine bone mineral and covered with a porcine-derived non-crosslinked collagen matrix (CM). Soft tissue healing was clinically evaluated on the basis of a specific healing index. Horizontal and vertical ridge dimensional changes were assessed clinically and radiographically at baseline and 6 months after implant placement. For histological and histomorphometric analysis, bone biopsies were harvested from the augmented sites during implant surgery 6 months after the socket preservation procedure. Results Clinically, healing proceeded uneventfully in all the sockets. A trend towards reduced horizontal and vertical socket dimensions was observed from baseline to the final examination. The mean width and height of resorption were 1.21 mm (P=0.005) and 0.46 mm (P=0.004), respectively. Histologically, residual xenograft particles (31.97%±3.52%) were surrounded by either newly formed bone (16.02%±7.06%) or connective tissue (50.67%±8.42%) without fibrous encapsulation. The CM underwent a physiological substitution process in favour of well-vascularised collagen-rich connective tissue. Conclusions Socket preservation using demineralised bovine bone mineral in combination with CM provided stable dimensional changes of the alveolar ridge associated with good re-epithelialisation of the soft tissues during a 6-month healing period. PMID:28861284
Madan, Rohit; Mohan, Ranjana; Bains, Vivek K; Gupta, Vivek; Singh, G P; Madan, Mani
2014-01-01
The aim of this study was to evaluate the extraction socket healing and dimensional changes following alveolar ridge preservation using polylactide and polyglycolide (PLA-PGA) sponge. Fifteen patients were selected for alveolar socket preservation immediately following tooth extraction. Monoradicular maxillary and mandibular teeth were evaluated. The selected sockets had intact sockets walls with a minimum of 7 mm of residual alveolar bone height. The test sites were thoroughly debrided and grafted with PLA-PGA sponge, while the control sites underwent natural healing. Computed tomography (CT) measurements were taken at baseline and 6 months. After 6 months of healing, final CT measurements were performed, and trephine core biopsy specimens were obtained for histologic analysis. Implants were placed immediately after biopsy harvesting. All subjects completed the study, and all sites healed without adverse events and allowed for implant placement. The mean difference in socket height, width, and density after 6 months was statistically significantly higher in the test sites compared with control sites. Clinical measurement at the midbuccal site of the alveolar socket showed a mean loss of 2.45 ± 0.67 mm in the control group, compared with a mean gain of 1.28 ± 0.58 mm in the test group. All test sites showed minimal ridge alterations, and statistically significant differences were observed between the test and control sites with respect to bone composition and horizontal and vertical bone loss, indicating that PLA-PGA sponge is suitable for alveolar ridge preservation.
An Introduction to Message-Bus Architectures for Space Systems
NASA Technical Reports Server (NTRS)
Smith, Danford; Gregory, Brian
2005-01-01
This course presents technical and programmatic information on the development of message-based architectures for space mission ground and flight software systems. Message-based architecture approaches provide many significant advantages over the more traditional socket-based one-of-a-kind integrated system development approaches. The course provides an overview of publish/subscribe concepts, the use of common isolation layer API's, approaches to message standardization, and other technical topics. Several examples of currently operational systems are discussed and possible changes to the system discussed and time for questions and answers will be provided.
Open Source Software Projects Needing Security Investments
2015-06-19
modtls, BouncyCastle, gpg, otr, axolotl. 7. Static analyzers: Clang, Frama-C. 8. Nginx. 9. OpenVPN . It was noted that the funding model may be similar...to OpenSSL, where consulting funds the company. It was also noted that OpenVPN needs to correctly use OpenSSL in order to be secure, so focusing on...Dovecot 4. Other high-impact network services: OpenSSH, OpenVPN , BIND, ISC DHCP, University of Delaware NTPD 5. Core infrastructure data parsers
Insights into accelerated aging of SSL luminaires
NASA Astrophysics Data System (ADS)
Davis, J. Lynn; Lamvik, Michael; Bittle, James; Shepherd, Sarah; Yaga, Robert; Baldasaro, Nick; Solano, Eric; Bobashev, Georgiy
2013-09-01
Although solid-state lighting (SSL) products are often intended to have product lifetimes of 15 years or more, the rapid change in technology has created a need for accelerated life tests (ALTs) that can be performed in the span of several months. A critical element of interpreting results from any systems-level ALT is understanding of the impact of the test environment on each component. Because of its ubiquity in electronics, the use of temperature-humidity environments as potential ALTs for SSL luminaires was investigated. Results from testing of populations of three commercial 6" downlights in environments of 85°C and 85% relative humidity (RH) and 75°C and 75% RH are reported. These test environments were found to accelerate lumen depreciation of the entire luminaire optical system, including LEDs, lenses, and reflectors. The effects of aging were found to depend strongly on both the optical materials that were used and the design of the luminaire; this shows that the lumen maintenance behavior of SSL luminaires must be addressed at the optical systems level. Temperature-Humidity ALTs can be a useful test in understand lumainaire depreciation provided that proper consideration is given to the different aging rates of various materials. Since the impact of the temperature-humidity environment varies among components of the optical system, uniform aging of all system components in a single test is difficult to achieve.
Insights into accelerated aging of SSL luminaires
Davis, J. Lynn; Lamvik, Michael; Bittle, James; ...
2013-09-30
Although solid-state lighting (SSL) products are often intended to have product lifetimes of 15 years or more, the rapid change in technology has created a need for accelerated life tests (ALTs) that can be performed in the span of several months. A critical element of interpreting results from any systems-level ALT is understanding of the impact of the test environment on each component. Because of its ubiquity in electronics, the use of temperature-humidity environments as potential ALTs for SSL luminaires was investigated. Results from testing of populations of three commercial 6” downlights in environments of 85oC and 85% relative humiditymore » (RH) and 75oC and 75% RH are reported. These test environments were found to accelerate lumen depreciation of the entire luminaire optical system, including LEDs, lenses, and reflectors. The effects of aging were found to depend strongly on both the optical materials that were used and the design of the luminaire; this shows that the lumen maintenance behavior of SSL luminaires must be addressed at the optical systems level. Temperature-Humidity ALTs can be a useful test in understand lumainaire depreciation provided that proper consideration is given to the different aging rates of various materials. Since the impact of the temperature-humidity environment varies among components of the optical system, uniform aging of all system components in a single test is difficult to achieve.« less
The secondary spiral lamina and its relevance in cochlear implant surgery.
Agrawal, Sumit; Schart-Morén, Nadine; Liu, Wei; Ladak, Hanif M; Rask-Andersen, Helge; Li, Hao
2018-03-01
We used synchrotron radiation phase contrast imaging (SR-PCI) to study the 3D microanatomy of the basilar membrane (BM) and its attachment to the spiral ligament (SL) (with a conceivable secondary spiral lamina [SSL] or secondary spiral plate) at the round window membrane (RWM) in the human cochlea. The conception of this complex anatomy may be essential for accomplishing structural preservation at cochlear implant surgery. Sixteen freshly fixed human temporal bones were used to reproduce the BM, SL, primary and secondary osseous spiral laminae (OSL), and RWM using volume-rendering software. Confocal microscopy immunohistochemistry (IHC) was performed to analyze the molecular constituents. SR-PCI reproduced the soft tissues including the RWM, Reissner's membrane (RM), and the BM attachment to the lateral wall (LW) in three dimensions. A variable SR-PCI contrast enhancement was recognized in the caudal part of the SL facing the scala tympani (ST). It seemed to represent a SSL allied to the basilar crest (BC). The SSL extended along the postero-superior margin of the round window (RW) and immunohistochemically expressed type II collagen. Unlike in several mammalian species, the human SSL is restricted to the most basal portion of the cochlea around the RW. It anchors the BM and may influence its hydro-mechanical properties. It could also help to shield the BM from the RW. The microanatomy should be considered at cochlear implant surgery.
Single site laparoscopy for fertility preservation: a cohort study.
Núñez Valera, María José; Padilla Iserte, Pablo; Higueras García, Gema; Herraiz, Sonia; Rubio, José María; Romeu Villarroya, Mónica; Pellicer, Antonio; Díaz-García, César
2015-02-01
To compare operative and postoperative results of ovarian cortex retrieval by conventional laparoscopy (1cm umbilical site and 3 accessory 5-mm-reusable working ports) (HASS) versus single site laparoscopy (SSL). Prospective cohort study. Fertility Preservation Programme at La Fe University Hospital-University of Valencia, Valencia, Spain, 2011 to 2012. Fertility Preservation Programme at La Fe University Hospital of Valencia, Valencia, Spain. Twenty-one patients with cancer (breast cancer: n = 17; Hodgkin's lymphoma: n = 3; and non-Hodgkin's lymphoma: n = 1). Ovarian cortex retrieval either by conventional laparoscopy using an umbilical Hasson port and 3 accessory ports (HASS group: n = 11) or by SSL (SSL group: n = 10). Operative length, blood loss, postoperative pain (visual analog scale for pain at 6, 24, and 48 hours), need of additional analgesia, quality of life (European Quality of Life-5 Dimensions), cosmesis of the scar, and patient's self-perception were assessed at 24 and 48 hours and 3 months after surgery. Baseline characteristics were similar between groups. Estimated blood loss, operative length, and postoperative pain did not differ between groups. The start of chemotherapy was not delayed in either group, and cosmesis and image self-perception were also similar. The SSL approach can be considered a safe option compared with the classic multisite approach. Copyright © 2015 AAGL. Published by Elsevier Inc. All rights reserved.
Sparks, Rachel; Madabhushi, Anant
2016-01-01
Content-based image retrieval (CBIR) retrieves database images most similar to the query image by (1) extracting quantitative image descriptors and (2) calculating similarity between database and query image descriptors. Recently, manifold learning (ML) has been used to perform CBIR in a low dimensional representation of the high dimensional image descriptor space to avoid the curse of dimensionality. ML schemes are computationally expensive, requiring an eigenvalue decomposition (EVD) for every new query image to learn its low dimensional representation. We present out-of-sample extrapolation utilizing semi-supervised ML (OSE-SSL) to learn the low dimensional representation without recomputing the EVD for each query image. OSE-SSL incorporates semantic information, partial class label, into a ML scheme such that the low dimensional representation co-localizes semantically similar images. In the context of prostate histopathology, gland morphology is an integral component of the Gleason score which enables discrimination between prostate cancer aggressiveness. Images are represented by shape features extracted from the prostate gland. CBIR with OSE-SSL for prostate histology obtained from 58 patient studies, yielded an area under the precision recall curve (AUPRC) of 0.53 ± 0.03 comparatively a CBIR with Principal Component Analysis (PCA) to learn a low dimensional space yielded an AUPRC of 0.44 ± 0.01. PMID:27264985
2017-10-01
AWARD NUMBER: W81XWH-16-1-0785 TITLE: Prosthetic Smart Socket Technology to Improve Patient Interaction, Usability, Comfort, Fit and Function...2016 - 29 Sep 2017 4. TITLE AND SUBTITLE Prosthetic Smart Socket Technology to Improve Patient Interaction, Usability, Comfort, Fit and Function 5a...discomfort. 2. KEYWORDS: Provide a brief list of keywords (limit to 20 words). Prosthesis, prosthesis fit, technology , skin problems, amputee
Mello, C C; Lemos, C A A; Verri, F R; Dos Santos, D M; Goiato, M C; Pellizzer, E P
2017-09-01
The aim of this systematic review and meta-analysis was to compare the survival rate of the implants and the peri-implant tissue changes associated with implants inserted in fresh extraction sockets and those inserted in healed sockets. This review has been registered at PROSPERO under the number CRD42016043309. A systematic search was conducted by two reviewers independently in the databases PubMed/MEDLINE, Embase, and the Cochrane Library using different search terms; articles published until November 2016 were searched for. The searches identified 30 eligible studies. A total of 3,049 implants were installed in a total of 1,435 patients with a mean age of 46.68 years and a minimum of 6 months of follow-up. The survival rate of delayed implants (98.38%) was significantly greater than immediate implants (95.21%) (p=.001). For the marginal bone loss (p=.32), implant stability quotients values (p=.44), and pocket probing depth (p=.94) there was no significant difference between the analysed groups. The immediate implants placed in fresh sockets should be performed with caution because of the significantly lower survival rates than delayed implants inserted in healed sockets. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
[The effect of osteogenic inducer on healing of tooth extraction sockets].
Chen, Junliang; Shan, Chuncheng; He, Yun; Xia, Delin
2012-06-01
To study the effect of osteogenic inducer (dexamethasone, beta-sodium glycerophosphate and Vitamin C) carried by gelatin sponge on healing and remodeling of tooth extraction sockets. Fifty rabbits were selected. After extracting the first premolars of bilateral maxillary, the right side tooth extraction sockets were filled with gelatin sponge containing osteogenic inducer as experimental side, tooth extraction sockets on left side were filled with gelatin sponge as control. Every ten rabbits were executed at the end of 1, 2, 4, 8, 12 weeks after tooth extraction. Bone density was measured through digital X-ray images. The specimens were examined by histology. The absorption height of alveolar bone at 12 weeks was measured. X-ray measurement showed that the bone density of experimental side was higher than that of control side at 2, 4, 8, 12 weeks, the difference had statistical significance (P<0.01). The histology examination showed that new bone formation in tooth extraction sockets of experimental side was earlier than that in control side. The absorptional height of alveolar bone had significant difference between experimental side and control side (P<0.01), of which experimental side was less. Filling the osteogenic inducer in tooth extraction sockets can promote the healing and new bone formation and prevent from alveolar bone absorption.
Hefferman, Gerald M; Zhang, Fan; Nunnery, Michael J; Huang, He
2015-04-01
In recent years, there has been an increased interest in recording high-quality electromyographic signals from within the sockets of lower-limb amputees. However, successful recording presents major challenges to both researchers and clinicians. This article details and compares four prototypical integrated socket-sensor designs used to record electromyographic signals from within the sockets of transfemoral amputees. Four prototypical socket-sensor configurations were constructed and tested on a single transfemoral amputee asked to perform sitting/standing, stair ascent/descent, and level ground walking. The number of large-amplitude motion artifacts generated using each prototype was quantified, the amount of skin irritation documented, and the comfort level of each assembly subjectively assessed by the amputee subject. Of the four configurations tested, the combination of a suction socket with integrated wireless surface electrodes generated the lowest number of large-amplitude motion artifacts, the least visible skin irritation, and was judged to be most comfortable by the amputee subject. The collection of high-quality electromyographic signals from an amputee's residual limb while maximizing patient comfort holds substantial potential to enhance neuromuscular clinical assessment and as a method of intuitive control of powered lower-limb prostheses. © The International Society for Prosthetics and Orthotics 2014.
Detection of Prosthetic Knee Movement Phases via In-Socket Sensors: A Feasibility Study
El-Sayed, Amr M.; Tan, Kenneth Y. S.; Abu Osman, Noor Azuan
2015-01-01
This paper presents an approach of identifying prosthetic knee movements through pattern recognition of mechanical responses at the internal socket's wall. A quadrilateral double socket was custom made and instrumented with two force sensing resistors (FSR) attached to specific anterior and posterior sites of the socket's wall. A second setup was established by attaching three piezoelectric sensors at the anterior distal, anterior proximal, and posterior sites. Gait cycle and locomotion movements such as stair ascent and sit to stand were adopted to characterize the validity of the technique. FSR and piezoelectric outputs were measured with reference to the knee angle during each phase. Piezoelectric sensors could identify the movement of midswing and terminal swing, pre-full standing, pull-up at gait, sit to stand, and stair ascent. In contrast, FSR could estimate the gait cycle stance and swing phases and identify the pre-full standing at sit to stand. FSR showed less variation during sit to stand and stair ascent to sensitively represent the different movement states. The study highlighted the capacity of using in-socket sensors for knee movement identification. In addition, it validated the efficacy of the system and warrants further investigation with more amputee subjects and different sockets types. PMID:25945365
Chen, J; He, Y; Shan, C; Pan, Q; Li, M; Xia, D
2015-10-01
An osteogenic inducer (OI) consisting of dexamethasone, vitamin C, and β-sodium glycerophosphate has the capacity to induce bone formation in vitro. The aim of this study was to assess the efficacy of the application of this OI on extraction socket healing. The bilateral first mandibular premolars were extracted from 75 New Zealand rabbits. Gelatin sponges carrying OI were implanted into the sockets. Sockets undergoing implantation of gelatin sponges alone were also evaluated, as well as non-implantation sockets. Specimens from each group were evaluated radiographically, histologically, and histomorphometrically using haematoxylin-eosin staining. Results showed earlier new bone formation and higher bone quality and quantity in the OI group compared to the other groups, and the differences were significant at 2, 4, 8, and 12 weeks postoperative. The OI significantly reduced the absorption of alveolar bone in terms of height; however, changes in the width were not significantly different between the three groups (P>0.05). The OI was shown to have a positive effect on healing of the tooth extraction sockets, was inexpensive, and was convenient to use during the operational procedure; therefore this could represent a promising implant material for human clinical application. Copyright © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Sequential healing of open extraction sockets. An experimental study in monkeys.
Scala, Alessandro; Lang, Niklaus P; Schweikert, Michael T; de Oliveira, José Américo; Rangel-Garcia, Idelmo; Botticelli, Daniele
2014-03-01
To describe the sequential healing of open extraction sockets at which no attempts to obtain a primary closure of the coronal access to the alveolus have been made. The third mandibular premolar was extracted bilaterally in 12 monkeys, and no sutures were applied to close the wound. The healing after 4, 10, 20, 30, 90 and 180 days was morphometrically studied. After 4 days of healing, a blood clot mainly occupied the extraction sockets, with the presence of an inflammatory cells' infiltrate. A void was confined in the central zones of the coronal and middle regions, in continuity with the entrance of the alveoli. At 10 days, the alveolus was occupied by a provisional matrix, with new bone formation lining the socket bony walls. At 20 days, the amount of woven bone was sensibly increasing. At 30 days, the alveolar socket was mainly occupied by mineralized immature bone at different stages of healing. At 90 and 180 days, the amount of mineralized bone decreased and substituted by trabecular bone and bone marrow. Bundle bone decreased from 95.5% at 4 days to 7.6% at 180 days, of the whole length of the inner alveolar surface. Modeling processes start from the lateral and apical walls of the alveolus, leading to the closure of the socket with newly formed bone within a month from extraction. Remodeling processes will follow the previous stages, resulting in trabecular and bone marrow formation and in a corticalization of the socket access. © 2013 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.
Gürbüzer, Bahadir; Pikdöken, Levent; Tunali, Mustafa; Urhan, Muammer; Küçükodaci, Zafer; Ercan, Feriha
2010-05-01
To evaluate the effect of platelet-rich fibrin (PRF) on the early bone healing process with bone scintigraphy based on technetium-99m methylene diphosphonate uptake in third molar extraction sockets. Fourteen patients with bilaterally soft tissue impacted third mandibular molars were included in the study. The right and left impacted third molars were surgically extracted in the same session. PRF was randomly administered into one of the extraction sockets, whereas the contralateral sockets were left without treatment. Four weeks after surgery, scintigrams were obtained to evaluate scintigraphic differences between PRF-treated and non-PRF-treated sockets. After completion of the clinical study, PRF samples were evaluated by light and scanning electron microscopy. The average increase in technetium-99m methylene diphosphonate uptake as an indication of enhanced bone healing did not differ significantly between PRF-treated and non-PRF-treated sockets 4 weeks postoperatively (P > .05). Abundant fibrin and inflammatory cells were observed by light microscopic examination of PRF samples. Scanning electron microscopic analysis of PRF revealed the existence of platelet aggregates in a fibrin network and crystalline particles on the outer surface of PRF. PRF might not lead to enhanced bone healing in soft tissue impacted mandibular third molar extraction sockets 4 weeks after surgery. PRF exhibits the potential characteristics of an autologous fibrin matrix. However, whether the presence of crystal-like particles on the outer surface of PRF alters bone healing should be investigated further. Copyright 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Effect of plasma rich in growth factors on alveolar osteitis
Haraji, Afshin; Lassemi, Eshagh; Motamedi, Mohammad Hosein Kalantar; Alavi, Maryam; Adibnejad, Saman
2012-01-01
Introduction: The high prevalence of dry socket or alveolar osteitis (AO) is of concern in surgical removal of third molars. The aim of the present study was to assess the preventive effect of plasma rich in growth factors (PRGF) on AO and also its effect on pain management and healing acceleration in third molar extraction sockets of high-risk patients. Materials and Methods: This split-mouth, double-blind clinical trial included 40 bilateral third molar extractions (80 sockets) with at least one identified risk factor for AO. PRGF was obtained from patient's own blood, based on manufacturer's instruction, and blindly placed in one of the two bilateral sockets (PRGF group; n = 20) of each patient. The contralateral socket was treated with a placebo (control group; n = 20). Samples were evaluated for AO and pain incidence on days 2, 3 and 4 and healing and infection on days 3 and 7. Data were analyzed in SPSS v16 using Wilcoxon test. Results: There was a significant difference in dry socket and pain incidence and healing rate between the two groups. Intensity of pain and occurrence of dry socket in the study group was lower than the controls. Also the healing rate was higher (P < 0.05) for the PRGF group. No sign of infection was seen in either group. Conclusion: The application of PRGF may significantly reduce the incidence of AO or its associated pain and may accelerate healing. The prophylactic use of PRGF following third molar extraction may be suggested especially in the patients at risk of AO. PMID:23251056
Discharge and infection in retinoblastoma post-enucleation sockets
Mourits, Daphne L; Hartong, Dyonne T; Budding, Andries E; Bosscha, Machteld I; Tan, H Stevie; Moll, Annette C
2017-01-01
Purpose To investigate the causes and treatment options for socket discharge and infection in patients enucleated for retinoblastoma (Rb). Methods A questionnaire was filled out by (parents of) ocular prosthesis-wearing patients with a history of enucleation as treatment for Rb. We collected data on patients’ characteristics, cleaning habits of the prosthesis, frequency of socket irritation, discharge, and infection, and use of antibiotics. With ordinal logistic regression analysis, factors related to the outcome parameters (frequency of irritation, mucoid and purulent discharge) were identified. In a subset of young asymptomatic and symptomatic patients, a swab culture of the socket was performed to determine the presence of microorganisms. Results A total of 186 patients or their parents (mean age of the patients: 17.3 years, ranging from 0.8 to 88.3 years) filled out the questionnaire. Irritation, mucoid discharge, and purulent discharge were frequently (once a month or more often) experienced in 75 (39.5%), 127 (66.8%), and 15 (13.2%) sockets, respectively. Younger age was associated with a higher frequency of mucoid and purulent discharge. Radiation therapy, chemotherapy, gender, age at surgery, cleaning frequency, and nocturnal wear were not associated with the outcome parameters. In a subgroup of 26 patients, the sockets were swabbed and cultured. All symptomatic patients had a positive bacterial culture versus 15% (2/13) of the asymptomatic patients (P<0.001). Common cold was correlated with both symptoms and presence of bacteria. Haemophilus influenzae and Staphylococcus aureus were the species most frequently cultured. Conclusion Ocular prosthesis-wearing patients often experienced mucoid discharge, and less often irritation and socket infection. These complaints were found to decrease with increasing age, but did not seem to be influenced by cleaning or wearing habits. Symptomatic sockets, with and without discharge, were correlated with the presence of pathogenic bacteria for which local antibiotic treatment seemed effective in most cases. PMID:28280296
Cooper, Lyndon F; Reside, Glenn J; Raes, Filiep; Garriga, Joan Soliva; Tarrida, Luis Giner; Wiltfang, Jörg; Kern, Matthias; De Bruyn, Hugo
2014-01-01
This 5-year prospective multicenter study compared implant survival and success, peri-implant health and soft tissue responses, crestal bone level stability, and complication rates following immediate loading of single OsseoSpeed implants placed in anterior maxillary healed ridges or extraction sockets. Individuals requiring anterior tooth replacement with single implants were treated and immediately provisionalized. Definitive all-ceramic crowns were placed at 12 weeks. Implant survival, bone levels, soft tissue levels, and peri-implant health were monitored for 5 years. One hundred thirteen patients received implants in fresh sockets (55) and healed ridges (58). After 5 years, 45 and 49 patients remained for evaluation, respectively. During the first year, three implants failed in the extraction socket group (94.6% survival) and one implant failed in the healed ridge group (98.3% survival); this difference was not significant. No further implant failures were recorded. After 5 years, the interproximal crestal bone levels were located a mean of 0.43 ± 0.63 mm and 0.38 ± 0.62 mm from the reference points of implants in sockets and healed ridges (not a significant difference). In both groups, papillae increased over time and peri-implant mucosal zenith positions were stable from the time of definitive crown placement in sockets and healed ridges. Compared to flap surgery for implants in healed ridges, flapless surgery resulted in increased peri-implant mucosal tissue dimension (average, 0.78 ± 1.34 mm vs 0.19 ± 0.79 mm). After 5 years, the bone and soft tissue parameters that characterize implant success and contribute to dental implant esthetics were similar following the immediate provisionalization of implants in sockets and healed ridges. The overall tissue responses and reported implant survival support the immediate provisionalization of dental implants in situations involving healed ridges and, under ideal circumstances, extraction sockets.
Discharge and infection in retinoblastoma post-enucleation sockets.
Mourits, Daphne L; Hartong, Dyonne T; Budding, Andries E; Bosscha, Machteld I; Tan, H Stevie; Moll, Annette C
2017-01-01
To investigate the causes and treatment options for socket discharge and infection in patients enucleated for retinoblastoma (Rb). A questionnaire was filled out by (parents of) ocular prosthesis-wearing patients with a history of enucleation as treatment for Rb. We collected data on patients' characteristics, cleaning habits of the prosthesis, frequency of socket irritation, discharge, and infection, and use of antibiotics. With ordinal logistic regression analysis, factors related to the outcome parameters (frequency of irritation, mucoid and purulent discharge) were identified. In a subset of young asymptomatic and symptomatic patients, a swab culture of the socket was performed to determine the presence of microorganisms. A total of 186 patients or their parents (mean age of the patients: 17.3 years, ranging from 0.8 to 88.3 years) filled out the questionnaire. Irritation, mucoid discharge, and purulent discharge were frequently (once a month or more often) experienced in 75 (39.5%), 127 (66.8%), and 15 (13.2%) sockets, respectively. Younger age was associated with a higher frequency of mucoid and purulent discharge. Radiation therapy, chemotherapy, gender, age at surgery, cleaning frequency, and nocturnal wear were not associated with the outcome parameters. In a subgroup of 26 patients, the sockets were swabbed and cultured. All symptomatic patients had a positive bacterial culture versus 15% (2/13) of the asymptomatic patients ( P <0.001). Common cold was correlated with both symptoms and presence of bacteria. Haemophilus influenzae and Staphylococcus aureus were the species most frequently cultured. Ocular prosthesis-wearing patients often experienced mucoid discharge, and less often irritation and socket infection. These complaints were found to decrease with increasing age, but did not seem to be influenced by cleaning or wearing habits. Symptomatic sockets, with and without discharge, were correlated with the presence of pathogenic bacteria for which local antibiotic treatment seemed effective in most cases.
Three-Dimensional Wiring for Extensible Quantum Computing: The Quantum Socket
NASA Astrophysics Data System (ADS)
Béjanin, J. H.; McConkey, T. G.; Rinehart, J. R.; Earnest, C. T.; McRae, C. R. H.; Shiri, D.; Bateman, J. D.; Rohanizadegan, Y.; Penava, B.; Breul, P.; Royak, S.; Zapatka, M.; Fowler, A. G.; Mariantoni, M.
2016-10-01
Quantum computing architectures are on the verge of scalability, a key requirement for the implementation of a universal quantum computer. The next stage in this quest is the realization of quantum error-correction codes, which will mitigate the impact of faulty quantum information on a quantum computer. Architectures with ten or more quantum bits (qubits) have been realized using trapped ions and superconducting circuits. While these implementations are potentially scalable, true scalability will require systems engineering to combine quantum and classical hardware. One technology demanding imminent efforts is the realization of a suitable wiring method for the control and the measurement of a large number of qubits. In this work, we introduce an interconnect solution for solid-state qubits: the quantum socket. The quantum socket fully exploits the third dimension to connect classical electronics to qubits with higher density and better performance than two-dimensional methods based on wire bonding. The quantum socket is based on spring-mounted microwires—the three-dimensional wires—that push directly on a microfabricated chip, making electrical contact. A small wire cross section (approximately 1 mm), nearly nonmagnetic components, and functionality at low temperatures make the quantum socket ideal for operating solid-state qubits. The wires have a coaxial geometry and operate over a frequency range from dc to 8 GHz, with a contact resistance of approximately 150 m Ω , an impedance mismatch of approximately 10 Ω , and minimal cross talk. As a proof of principle, we fabricate and use a quantum socket to measure high-quality superconducting resonators at a temperature of approximately 10 mK. Quantum error-correction codes such as the surface code will largely benefit from the quantum socket, which will make it possible to address qubits located on a two-dimensional lattice. The present implementation of the socket could be readily extended to accommodate a quantum processor with a (10 ×10 )-qubit lattice, which would allow for the realization of a simple quantum memory.
Biomechanical Analysis of a Filiform Mechanosensory Hair Socket of Crickets.
Joshi, Kanishka; Mian, Ahsan; Miller, John
2016-08-01
Filiform mechanosensory hairs of crickets are of great interest to engineers because of the hairs' highly sensitive response to low-velocity air-currents. In this study, we analyze the biomechanical properties of filiform hairs of the cercal sensory system of a common house cricket. The cercal sensory system consists of two antennalike appendages called cerci that are situated at the rear of the cricket's abdomen. Each cercus is covered with 500-750 flow sensitive filiform mechanosensory hairs. Each hair is embedded in a complex viscoelastic socket that acts as a spring and dashpot system and guides the movement of the hair. When a hair deflects due to the drag force induced on its length by a moving air-current, the spiking activity of the neuron that innervates the hair changes and the combined spiking activity of all hairs is extracted by the cercal sensory system. Filiform hairs have been experimentally studied by researchers, though the basis for the hairs' biomechanical characteristics is not fully understood. The socket structure has not been analyzed experimentally or theoretically from a mechanical standpoint, and the characterization that exists is mathematical in nature and only provides a very rudimentary approximation of the socket's spring nature. This study aims to understand and physically characterize the socket's behavior and interaction with the filiform hair by examining hypotheses about the hair and socket biomechanics. A three-dimensional computer-aided design (CAD) model was first created using confocal microscopy images of the hair and socket structure of the cricket, and then finite-element analyses (FEAs) based on the physical conditions that the insect experiences were simulated. The results show that the socket can act like a spring; however, it has two-tier rotational spring constants during pre- and postcontacts of iris and hair bulge due to its constitutive nonstandard geometric shapes.
Evora® chromium-cobalt dual mobility socket: results at a minimum 10 years' follow-up.
Leclercq, S; Benoit, J Y; de Rosa, J P; Tallier, E; Leteurtre, C; Girardin, P H
2013-12-01
The Evora chromium-cobalt alloy dual mobility socket claims to display a large articulation tribology different from that of stainless steel models, limiting the risk of intraprosthetic dislocation and wear. The present study reports a minimum of 10years' follow-up in a multicenter prospective series of 200 sockets previously reported on at 5years. The use of chromium-cobalt in dual mobility sockets provides a low rate of failure at 10years, especially as regards to osteolysis and intraprosthetic dislocation. Two hundred hydroxyapatite-coated molded chromium-cobalt sockets without titanium interface were implanted without cement in 194 patients with a mean age of 70 years (range, 32-91 years). Clinical results were assessed on Postel Merle d'Aubigné and Harris scores, plain radiographs and survival analysis. At a mean 11 years' follow-up (10-13 years), 56 patients had died and 31 were lost to follow-up. Four underwent surgical revision (3 femoral components, and 1 socket for migration at 9 years with complete disappearance of the hydroxyapatite). A total of 109 implants were analyzable in 107 patients with a mean age of 81 years (55-93 years). At follow-up, the mean Harris score was 90 (75-96) and the PMA score 16.3 (14-18). There were no cases of loosening (except for the case reoperated on at 9 years) and no acetabular radiolucency or cysts. There were 2 cases of non-evolutive femoral radiolucency and 10 of femoral granuloma, involving head size > 22 mm (P<0.0001) and a cemented titanium stem (P=0.004) as risk factors. There were no dislocations in the large or small articulation. Ten-year survival was 99% (95% CI: 97.3%-100%) with socket revision as censorship criterion. The absence of dislocation in both small and large articulations confirmed the efficacy of the dual mobility concept and suggested an advantage for chromium-cobalt sockets in reducing the rate of intraprosthetic dislocation and preventing blockage of the large articulation by a better performance in the friction couple. Granulomas were associated with wear in cemented titanium stems and with heads greater than 22 mm in diameter. Ten-year survival was 99% (censorship criterion: revision for socket failure); there was, however, one case of socket loosening with disappearance of the hydroxyapatite, indicating that surveillance should be continued in this cohort. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Beaubien, Brian P; Freeman, Andrew L; Buttermann, Glenn R
2016-01-25
The spinous processes and supraspinous and interspinous ligaments (SSL and ISL, respectively) limit flexion and may relate to spinal curvature. Spinous process angles and mechanical properties of explanted human thoracic posterior SSL/ISL complexes were compared for scoliosis (n=14) vs. kyphosis (n=8) patients. The median thoracic coronal Cobb angle for scoliosis patients was 48°, and sagittal angles for kyphosis patients was 78°. Spinous processes were gripped and four strain steps of 4% were applied and held. Percent relaxation was calculated over each step, equilibrium load data were fit to an exponential equation, and a Kelvin model was fit to the load from all four curves. Failure testing was also performed. Median ligament complex dimensions from scoliosis and kyphosis patients were, respectively: ISL width=16.5mm and 16.0mm; SSL width=4.3mm and 3.8mm; ISL+SSL area=17.2mm and 25.7mm; these differences were not significant. Significant differences did exist in terms of spinous process angle vs. spine axis (47° for scoliosis and 32° for kyphosis) and SSL thickness (2.1mm for scoliosis and 3.0mm for kyphosis). Fourth-step median relaxation was 42% for scoliosis and 49% for kyphosis. Median linear region stiffness was 42N/mm for scoliosis and 51N/mm for kyphosis. Median failure load was 191N for scoliotic and 175N for kyphotic ligaments. Differences in loading, relaxation, viscoelastic and failure parameters were not statistically significant, except for a trend for greater initial rate of relaxation (T1) for scoliosis ligaments. However, we found significant morphological differences related to the spinous processes, which suggests a need for future biomechanical studies related to the musculoskeletal aspects of spinal alignment and posture. Copyright © 2015 Elsevier Ltd. All rights reserved.
Becker, Sara J; Kelly, Lourah M; Kang, Augustine W; Escobar, Katherine I; Squires, Daniel D
2018-03-29
Contingency management (CM) is an evidence-based behavioral intervention for opioid use disorders (OUDs); however, CM adoption in OUD treatment centers remains low due to barriers at patient, provider, and organizational levels. In a recent trial, OUD treatment providers who received the Science to Service Laboratory (SSL), a multilevel implementation strategy developed by a federally funded addiction training center, had significantly greater odds of CM adoption than providers who received training as usual. This study examined whether CM adoption frequency varied as a function of provider sociodemographic characteristics (i.e., age, race/ethnicity, licensure) and perceived barriers to adoption (i.e., patient-, provider-, organization-level) among providers receiving the SSL in an opioid treatment program. Thirty-nine providers (67% female, 77% non-Hispanic white, 72% with specialty licensure, M age = 42 [SD = 11.46]) received the SSL, which consisted of didactic training, performance feedback, specialized training of internal change champions, and external coaching. Providers completed a comprehensive baseline assessment and reported on their adoption of CM biweekly for 52 weeks. Providers reported using CM an average of nine 2-week intervals (SD = 6.35). Hierarchical multiple regression found that providers identifying as younger, non-Hispanic white, and without addiction-related licensure all had higher levels of CM adoption frequency. Higher perceived patient-level barriers predicted lower levels of CM adoption frequency, whereas provider- and organization-level barriers were not significant predictors. The significant effect of age on CM adoption frequency was consistent with prior research on predictors of evidence-based practice adoption, whereas the effect of licensure was counter to prior research. The finding that CM adoption frequency was lower among racially/ethnically diverse providers was not expected and suggests that the SSL may require adaptation to meet the needs of diverse opioid treatment providers. Entities using the SSL may also wish to incorporate a more explicit focus on patient-level barriers.
Spatio-temporal patterns of soil erosion and suspended sediment dynamics in the Mekong River Basin.
Suif, Zuliziana; Fleifle, Amr; Yoshimura, Chihiro; Saavedra, Oliver
2016-10-15
Understanding of the distribution patterns of sediment erosion, concentration and transport in river basins is critically important as sediment plays a major role in river basin hydrophysical and ecological processes. In this study, we proposed an integrated framework for the assessment of sediment dynamics, including soil erosion (SE), suspended sediment load (SSL) and suspended sediment concentration (SSC), and applied this framework to the Mekong River Basin. The Revised Universal Soil Loss Equation (RUSLE) model was adopted with a geographic information system to assess SE and was coupled with a sediment accumulation and a routing scheme to simulate SSL. This framework also analyzed Landsat imagery captured between 1987 and 2000 together with ground observations to interpolate spatio-temporal patterns of SSC. The simulated SSL results from 1987 to 2000 showed the relative root mean square error of 41% and coefficient of determination (R(2)) of 0.89. The polynomial relationship of the near infrared exoatmospheric reflectance and the band 4 wavelength (760-900nm) to the observed SSC at 9 sites demonstrated the good agreement (overall relative RMSE=5.2%, R(2)=0.87). The result found that the severe SE occurs in the upper (China and Lao PDR) and lower (western part of Vietnam) regions. The SSC in the rainy season (June-November) showed increasing and decreasing trends longitudinally in the upper (China and Lao PDR) and lower regions (Cambodia), respectively, while the longitudinal profile of SSL showed a fluctuating trend along the river in the early rainy season. Overall, the results described the unique spatio-temporal patterns of SE, SSL and SSC in the Mekong River Basin. Thus, the proposed integrated framework is useful for elucidating complex process of sediment generation and transport in the land and river systems of large river basins. Copyright © 2016 Elsevier B.V. All rights reserved.
Peterson, Jeffrey R.; Blieden, Lauren S.; Chuang, Alice Z.; Baker, Laura A.; Rigi, Mohammed; Feldman, Robert M.; Bell, Nicholas P.
2016-01-01
Purpose Define criteria for iris-related parameters in an adult open angle population as measured with swept source Fourier domain anterior segment optical coherence tomography (ASOCT). Methods Ninety-eight eyes of 98 participants with open angles were included and stratified into 5 age groups (18–35, 36–45, 46–55, 56–65, and 66–79 years). ASOCT scans with 3D mode angle analysis were taken with the CASIA SS-1000 (Tomey Corporation, Nagoya, Japan) and analyzed using the Anterior Chamber Analysis and Interpretation software. Anterior iris surface length (AISL), length of scleral spur landmark (SSL) to pupillary margin (SSL-to-PM), iris contour ratio (ICR = AISL/SSL-to-PM), pupil radius, radius of iris centroid (RICe), and iris volume were measured. Outcome variables were summarized for all eyes and age groups, and mean values among age groups were compared using one-way analysis of variance. Stepwise regression analysis was used to investigate demographic and ocular characteristic factors that affected each iris-related parameter. Results Mean (±SD) values were 2.24 mm (±0.46), 4.06 mm (±0.27), 3.65 mm (±0.48), 4.16 mm (±0.47), 1.14 (±0.04), 1.51 mm2 (±0.23), and 38.42 μL (±4.91) for pupillary radius, RICe, SSL-to-PM, AISL, ICR, iris cross-sectional area, and iris volume, respectively. Both pupillary radius (P = 0.002) and RICe (P = 0.027) decreased with age, while SSL-to-PM (P = 0.002) and AISL increased with age (P = 0.001). ICR (P = 0.54) and iris volume (P = 0.49) were not affected by age. Conclusion This study establishes reference values for iris-related parameters in an adult open angle population, which will be useful for future studies examining the role of iris changes in pathologic states. PMID:26815917
Peterson, Jeffrey R; Blieden, Lauren S; Chuang, Alice Z; Baker, Laura A; Rigi, Mohammed; Feldman, Robert M; Bell, Nicholas P
2016-01-01
Define criteria for iris-related parameters in an adult open angle population as measured with swept source Fourier domain anterior segment optical coherence tomography (ASOCT). Ninety-eight eyes of 98 participants with open angles were included and stratified into 5 age groups (18-35, 36-45, 46-55, 56-65, and 66-79 years). ASOCT scans with 3D mode angle analysis were taken with the CASIA SS-1000 (Tomey Corporation, Nagoya, Japan) and analyzed using the Anterior Chamber Analysis and Interpretation software. Anterior iris surface length (AISL), length of scleral spur landmark (SSL) to pupillary margin (SSL-to-PM), iris contour ratio (ICR = AISL/SSL-to-PM), pupil radius, radius of iris centroid (RICe), and iris volume were measured. Outcome variables were summarized for all eyes and age groups, and mean values among age groups were compared using one-way analysis of variance. Stepwise regression analysis was used to investigate demographic and ocular characteristic factors that affected each iris-related parameter. Mean (±SD) values were 2.24 mm (±0.46), 4.06 mm (±0.27), 3.65 mm (±0.48), 4.16 mm (±0.47), 1.14 (±0.04), 1.51 mm2 (±0.23), and 38.42 μL (±4.91) for pupillary radius, RICe, SSL-to-PM, AISL, ICR, iris cross-sectional area, and iris volume, respectively. Both pupillary radius (P = 0.002) and RICe (P = 0.027) decreased with age, while SSL-to-PM (P = 0.002) and AISL increased with age (P = 0.001). ICR (P = 0.54) and iris volume (P = 0.49) were not affected by age. This study establishes reference values for iris-related parameters in an adult open angle population, which will be useful for future studies examining the role of iris changes in pathologic states.
NASA Astrophysics Data System (ADS)
Ferrer, Evelina G.; Gómez, Analía V.; Añón, María C.; Puppo, María C.
2011-06-01
Food protein product, gluten protein, was chemically modified by varying levels of sodium stearoyl lactylate (SSL); and the extent of modifications (secondary and tertiary structures) of this protein was analyzed by using Raman spectroscopy. Analysis of the Amide I band showed an increase in its intensity mainly after the addition of the 0.25% of SSL to wheat flour to produced modified gluten protein, pointing the formation of a more ordered structure. Side chain vibrations also confirmed the observed changes.
Comprehensive Routing Security Development and Deployment for the Internet
2015-02-01
feature enhancement and bug fixes. • MySQL : MySQL is a widely used and popular open source database package. It was chosen for database support in the...RPSTIR depends on several other open source packages. • MySQL : MySQL is used for the the local RPKI database cache. • OpenSSL: OpenSSL is used for...cryptographic libraries for X.509 certificates. • ODBC mySql Connector: ODBC (Open Database Connectivity) is a standard programming interface (API) for
Measurement of Forces and Moments Transmitted to the Residual Limb
2008-08-01
leg and residual limb, the condition of your residual limb including touch and pressure sensation, and the type of components used in your prosthesis ...measured by a tri-axial transducer mounted on the pylon of a transtibial prosthesis distal to the socket can be used to estimate the intra-socket...alignment has been developed, and IRB approval has been obtained. 15. SUBJECT TERMS Amputees, prosthesis alignment, socket pressure, gait, force and moment
2012-01-01
Background A cursory review of the current socket preservation literatures well depicts the necessity of further esthetic considerations through the corrective procedures of the alveolar ridge upon and post extraction. A new technique has been described here is a rotational pedicle combined epithelialized and connective tissue graft (RPC graft) adjunct with immediate guided tissue regeneration (GBR) procedure. Results We reviewed this technique through a case report and discuss it’s benefit in compare to other socket preservation procedures. Conclusion The main advantages of RPC graft would be summarized as follows: stable primary closure during bone remodeling, saving or crating sufficient vestibular depth, making adequate keratinized gingiva on the buccal surface, and being esthetically pleasant. PMID:22540920
Vane segment support and alignment device
McLaurin, L.D.; Sizemore, J.D.
1999-07-13
A support and alignment assembly for supporting and aligning a vane segment is provided. The support and alignment assembly comprises a torque plate which defines an opening for receiving an eccentric pin and a locking end member for receiving a lock socket member. An eccentric pin adjustably supported by the torque plate opening for supporting and aligning a vane segment is provided. A lock socket member adapted to securely receive the eccentric pin and rotated therewith, and adjustably engage the torque plate locking end is provided. The lock socket member receives the eccentric pin, such that when the eccentric pin is adjusted to align the vane segment, the lock socket member engages the torque plate locking end to secure the vane segment in the desired position. 5 figs.
Vane segment support and alignment device
McLaurin, Leroy Dixon; Sizemore, John Derek
1999-01-01
A support and alignment assembly for supporting and aligning a vane segment is provided. The support and alignment assembly comprises a torque plate which defines an opening for receiving an eccentric pin and a locking end member for receiving a lock socket member. An eccentric pin adjustably supported by the torque plate opening for supporting and aligning a vane segment is provided. A lock socket member adapted to securely receive the eccentric pin and rotated therewith, and adjustably engage the torque plate locking end is provided. The lock socket member receives the eccentric pin, such that when the eccentric pin is adjusted to align the vane segment, the lock socket member engages the torque plate locking end to secure the vane segment in the desired position.
Lu, Xiaoqi; Wang, Lei; Zhao, Jianfeng
2012-02-01
With the development of medical information, Picture Archiving and Communications System (PACS), Hospital Information System/Radiology Information System(HIS/RIS) and other medical information management system become popular and developed, and interoperability between these systems becomes more frequent. So, these enclosed systems will be open and regionalized by means of network, and this is inevitable. If the trend becomes true, the security of information transmission may be the first problem to be solved. Based on the need for network security, we investigated the Digital Imaging and Communications in Medicine (DICOM) Standard and Transport Layer Security (TLS) Protocol, and implemented the TLS transmission of the DICOM medical information with OpenSSL toolkit and DCMTK toolkit.
Active learning based segmentation of Crohns disease from abdominal MRI.
Mahapatra, Dwarikanath; Vos, Franciscus M; Buhmann, Joachim M
2016-05-01
This paper proposes a novel active learning (AL) framework, and combines it with semi supervised learning (SSL) for segmenting Crohns disease (CD) tissues from abdominal magnetic resonance (MR) images. Robust fully supervised learning (FSL) based classifiers require lots of labeled data of different disease severities. Obtaining such data is time consuming and requires considerable expertise. SSL methods use a few labeled samples, and leverage the information from many unlabeled samples to train an accurate classifier. AL queries labels of most informative samples and maximizes gain from the labeling effort. Our primary contribution is in designing a query strategy that combines novel context information with classification uncertainty and feature similarity. Combining SSL and AL gives a robust segmentation method that: (1) optimally uses few labeled samples and many unlabeled samples; and (2) requires lower training time. Experimental results show our method achieves higher segmentation accuracy than FSL methods with fewer samples and reduced training effort. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
From dark to bright: novel daylighting applications in solid state lighting
NASA Astrophysics Data System (ADS)
Adler, Helmar G.
2011-10-01
The term "daylighting" is used in various ways, on one hand in a more architectural sense, i.e. using existing daylight to illuminate spaces, and on the other, more recently, for using light sources to replicate daylight. The emergence of solid state lighting (SSL) opens up a large number of new avenues for daylighting. SSL allows innovative controllability of intensity and color for artificial light sources that can be advantageously applied to daylighting. With the assistance of these new technologies the combination of natural and artificial lighting could lead to improvements in energy savings and comfort of living beings. Thus it is imperative to revisit or even improve daylighting research so that building networks of the future with their sensor, energy (e.g. HVAC) and lighting requirements can benefit from the emerging capabilities. This paper will briefly review existing daylighting concepts and technology and discuss new ideas. An example of a tunable multi-color SSL system will be shown.
Single site laparoscopic right hemicolectomy: an oncological feasible option
2010-01-01
Introduction We present the first 7 cases of single site right hemicolectomy in Asia using the new Single Site Laparoscopy (SSL) access system from Ethicon Endo-surgery. Methods Right hemicolectomy was performed using the new Single Site Laparoscopy (SSL) access system. Patient demographics, operative time, histology and post operative recovery and complications were collected and analysed. Results The median operative time was 90 mins (range 60 - 150 mins) and a median wound size of 2.5 cm (range 2 to 4.5 cm). The median number of lymph nodes harvested was 24 (range 20 to 34 lymph nodes). The median length of proximal margin was 70 mm (range 30 to 145 mm) and that of distal margin was 50 mm (35 to 120 mm). All patients had a median hospital stay of 7 days (range 5 to 11) and there were no significant perioperative complications except for 1 patient who had a minor myocardial event. Conclusion Right hemicolectomy using SSL access system is feasible and safe for oncologic surgery. PMID:20825658
Wood, Sarah A; Strait, David S; Dumont, Elizabeth R; Ross, Callum F; Grosse, Ian R
2011-07-07
Several finite element models of a primate cranium were used to investigate the biomechanical effects of the tooth sockets and the material behavior of the periodontal ligament (PDL) on stress and strain patterns associated with feeding. For examining the effect of tooth sockets, the unloaded sockets were modeled as devoid of teeth and PDL, filled with teeth and PDLs, or simply filled with cortical bone. The third premolar on the left side of the cranium was loaded and the PDL was treated as an isotropic, linear elastic material using published values for Young's modulus and Poisson's ratio. The remaining models, along with one of the socket models, were used to determine the effect of the PDL's material behavior on stress and strain distributions under static premolar biting and dynamic tooth loading conditions. Two models (one static and the other dynamic) treated the PDL as cortical bone. The other two models treated it as a ligament with isotropic, linear elastic material properties. Two models treated the PDL as a ligament with hyperelastic properties, and the other two as a ligament with viscoelastic properties. Both behaviors were defined using published stress-strain data obtained from in vitro experiments on porcine ligament specimens. Von Mises stress and strain contour plots indicate that the effects of the sockets and PDL material behavior are local. Results from this study suggest that modeling the sockets and the PDL in finite element analyses of skulls is project dependent and can be ignored if values of stress and strain within the alveolar region are not required. Copyright © 2011 Elsevier Ltd. All rights reserved.
Kim, Jung-Ju; Schwarz, Frank; Song, Hyun Young; Choi, YoonMi; Kang, Kyung-Rim; Koo, Ki-Tae
2017-06-01
This study aimed to evaluate the dynamics of newly bone formation and dimensional change in diseased extraction sockets using Bio-Oss ® Collagen with or without a collagen membrane. In six beagle dogs, right and left 3rd and 4th mandibular premolars were hemisected and the distal roots were removed. Combined endodontic-periodontic lesions were induced in all sites using black silk, collagen sponge, endodontic files, and application of Porphyromonas gingivalis. After 4 months, among 4 premolars, three teeth were randomly selected per dog and allocated to the following experimental groups: Control group (no treatment but debridement), Test 1 group (only Bio-Oss ® Collagen graft), and Test 2 group (Bio-Oss ® Collagen graft with a collagen membrane). After 7 months from the baseline, the beagle dogs were sacrificed for histomorphometric and Micro-CT analysis. The vertical distance between buccal and lingual crests in the Control group (2.22 ± 0.26 mm) and Test 2 group (1.80 ± 0.16 mm) was significantly different. The socket of the Test 2 group (27.04 ± 5.25%) was occupied by a greater quantity of bone graft compared to the Test 1 group (18.49 ± 2.11%). Ridge preservation in diseased extraction sockets could compensate for buccal bone resorption by contact osteogenesis surrounding the bone graft particles at the bucco-coronal area during socket healing, and the application of a collagen membrane at the entrance of the socket is useful for preserving graft material at the coronal part of the socket. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Ennion, Liezel; Johannesson, Anton; Rhoda, Anthea
2017-10-01
Challenges exist with the provision of appropriate mobility assistive devices in rural areas. The use of the direct manufacturing prosthetic socket system is a possible solution to these challenges. The objective of this study was to test and explore the clients' perspectives with the application of this device. Within a mixed-methods approach, a longitudinal sequential explanatory design was applied. The Orthotic and Prosthetic User's Survey was administered to explore the use of the direct manufacturing prosthetic socket system in terms of function, health-related quality of life and client satisfaction. A conveniently selected sample of 21 individuals who suffered a unilateral trans-tibial amputation was included. Data were collected at 1, 3 and 6 months post fitting, and two focus group discussions were also administered. Of the 21 participants recruited, 11 returned for follow up. Although participants reported favourably about the prosthesis, their scores were generally worse than the norms with regard to function and quality of life. Participants highlighted the need for improvement in the cosmetic appearance of the prosthesis. The direct manufacturing prosthetic socket system could be considered as an alternative technique of socket manufacturing for individuals living in rural areas due to the shorter manufacture time and promising initial results, but further research on this topic with a bigger sample is recommended. Clinical relevance The direct manufacturing prosthetic socket system may be considered as an alternative to the traditional prosthetic socket manufacturing technique used in South Africa. As this device requires only one visit and therefore decreased travel by the patients to the hospitals, it could be applicable to more amputees who cannot return to hospital post discharge.
Leijendekkers, Ruud A; van Hinte, Gerben; Frölke, Jan Paul; van de Meent, Hendrik; Nijhuis-van der Sanden, Maria W G; Staal, J Bart
2017-06-01
This study aimed to provide an overview of a) the used measurement instruments in studies evaluating effects on quality of life (QoL), function, activity and participation level in patients with a lower extremity amputation using bone-anchored prostheses compared to socket prostheses and b) the effects themselves. A systematic literature search was conducted in MEDLINE, Cochrane, EMBASE, CINAHL and Web of Science. Included studies compared QoL, function, activity and/or participation level in patients with bone-anchored or socket prostheses. A best-evidence synthesis was performed. Out of 226 studies, five cohort and two cross-sectional studies were eligible for inclusion, all had methodological shortcomings. These studies used 10 different measurement instruments and two separate questions to assess outcome. Bone-anchored prostheses were associated with better condition-specific QoL and better outcomes on several of the physical QoL subscales, outcomes on the physical bodily pain subscale were inconclusive. Outcomes on function and activity level increased, no change was found at participation level. The level of evidence was limited. There is a need for a standard set of instruments. There was limited evidence that bone-anchored prostheses resulted in higher QoL, function and activity levels than socket prostheses, in patients with socket-related problems. Implications for Rehabilitation Use of bone-anchored prostheses in combination with intensive outpatient rehabilitation may improve QoL, function and activity level compared with socket prosthesis use in patients with a transfemoral amputation and socket-related problems. All clinicians and researchers involved with bone-anchored prostheses should use and publish data on QoL, function, activity and participation level. There needs to be an agreement on a standard set of instruments so that interventions for patients with a lower extremity amputation are assessed consistently.
Taberner-Vallverdú, M; Sánchez-Garcés, M-Á; Gay-Escoda, C
2017-11-01
Dry socket is one of the most common complications that develops after the extraction of a permanent tooth, and its prevention is more effective than its treatment. Analyze the efficacy of different methods used in preventing dry socket in order to decrease its incidence after tooth extraction. A Cochrane and PubMed-MEDLINE database search was conducted with the search terms "dry socket", "prevention", "risk factors", "alveolar osteitis" and "fibrynolitic alveolitis", both individually and using the Boolean operator "AND". The inclusion criteria were: clinical studies including at least 30 patients, articles published from 2005 to 2015 and written in English. The exclusion criteria were case reports and nonhuman studies. 30 publications were selected from a total of 250. Six of the 30 were excluded after reading the full text. The final review included 24 articles: 9 prospective studies, 2 retrospective studies and 13 clinical trials. They were stratified according to their level of scientific evidence using SIGN criteria (Scottish Intercollegiate Guidelines Network). All treatments included in the review were aimed at decreasing the incidence of dry socket. Locally administering chlorhexidine or applying platelet-rich plasma reduces the likelihood of developing this complication. Antibiotic prescription does not avoid postoperative complications after lower third molar surgery. With regard to risk factors, all of the articles selected suggest that patient age, history of previous infection and the difficulty of the extraction are the most common predisposing factors for developing dry socket. There is no consensus that smoking, gender or menstrual cycles are risk factors. Taking the scientific quality of the articles evaluated into account, a level B recommendation has been given for the proposed-procedures in the prevention of dry socket.
Childers, Walter Lee; Siebert, Steven
2016-12-01
Limb movement between the residuum and socket continues to be an underlying factor in limb health, prosthetic comfort, and gait performance yet techniques to measure this have been underdeveloped. Develop a method to measure motion between the residual limb and a transtibial prosthetic socket. Single subject, repeated measures with mathematical modeling. The gait of a participant with transtibial amputation was recorded using a motion capture system using a marker set that included arrays on the anterior distal tibia and the lateral epicondyle of the femur. The proximal or distal translation, anterior or posterior translation, and angular movements were quantified. A random Monte Carlo simulation based on the precision of the motion capture system and a model of the bone moving under the skin explored the technique's accuracy. Residual limb tissue stiffness was modeled as a linear spring based on data from Papaioannou et al. Residuum movement relative to the socket went through ~30 mm, 18 mm, and 15° range of motion. Root mean squared errors were 5.47 mm, 1.86 mm, and 0.75° when considering the modeled bone-skin movement in the proximal or distal, anterior or posterior, and angular directions, respectively. The measured movement was greater than the root mean squared error, indicating that this method can measure motion between the residuum and socket. The ability to quantify movement between the residual limb and the prosthetic socket will improve prosthetic treatment through the evaluation of different prosthetic suspensions, socket designs, and motor control of the prosthetic interface. © The International Society for Prosthetics and Orthotics 2015.
Choi, Jisoo; Shin, Dong-Ah; Kim, Sohee
2017-03-15
A three-dimensional finite element model of intact lumbar spine was constructed and four surgical finite element models implanted with ball-and-socket artificial discs with four different radii of curvature were compared. To investigate biomechanical effects of the curvature of ball-and-socket artificial disc using finite element analysis. Total disc replacement (TDR) has been accepted as an alternative treatment because of its advantages over spinal fusion methods in degenerative disc disease. However, the influence of the curvature of artificial ball-and-socket discs has not been fully understood. Four surgical finite element models with different radii of curvature of ball-and-socket artificial discs were constructed. The range of motion (ROM) increased with decreasing radius of curvature in extension, flexion, and lateral bending, whereas it increased with increasing radius of curvature in axial torsion. The facet contact force was minimum with the largest radius of curvature in extension, flexion, and lateral bending, whereas it was maximum with the largest radius in axial torsion. It was also affected by the disc placement, more with posterior placement than anterior placement. The stress in L4 cancellous bone increased when the radius of curvature was too large or small. The geometry of ball-and-socket artificial disc significantly affects the ROM, facet contact force, and stress in the cancellous bone at the surgical level. The implication is that in performing TDR, the ball-and-socket design may not be ideal, as ROM and facet contact force are sensitive to the disc design, which may be exaggerated by the individual difference of anatomical geometry. N/A.
2017-10-01
significantly lower trim lines, without ischial containment compared with a traditional interface. However, these alternative designs could compromise...overall function compared to the standard of care interface design . Therefore the focus of this clinical trial is to determine if the DS and Sub-I...alternative interface designs will improve socket comfort, residual limb health and function compared to the standard of care IRC interface design . 15
Samandari, Mohammad Hasan; Haghighat, Abbas; Torabinia, Nakisa; Taghian, Mehdi; Sadri, Leyli; Naemy, Vahid
2016-01-01
Background: Plasma rich in growth factors (PRGF) and freeze-dried bone allograft (FDBA) are shown to promote bone healing. This study was aimed to histologically and histomorphometrically investigate the effect of combined use of PRGF and FDBA on bone formation, and compare it to FDBA alone and control group. Materials and Methods: The distal roots of the lower premolars were extracted bilaterally in four female dogs. Sockets were randomly divided into FDBA + PRGF, FDBA, and control groups. Two dogs were sacrificed after 2 weeks and two dogs were sacrificed after 4 weeks. Sockets were assessed histologically and histomorphometrically. Data were analyzed by Kruskal–Wallis test followed by Mann–Whitney U-tests utilizing the SPSS software version 20. P < 0.05 was considered statistically significant. Results: While the difference in density of fibrous tissue in three groups was not statistically significant (P = 0.343), the bone density in grafted groups was significantly higher than the control group (P = 0.021). The least decrease in all socket dimensions was observed in the FDBA group. However, these differences were only significant in coronal portion at week 4. Regarding socket dimensions and bone density, the difference between FDBA and FDBA+PRGF groups was not significant in middle and apical portions. Conclusion: The superiority of PRGF+FDBA overFDBA in socket preservation cannot be concluded from this experiment. PMID:27857769
Chu, Stephen J; Sarnachiaro, Guido O; Hochman, Mark N; Tarnow, Dennis P
2015-01-01
Immediate implant therapy involving implants placed into intact Type 1 extraction sockets has become a consistent clinical technique. The classification of Type 2 extraction sockets, where the mucosal tissues are present but there is a midfacial osseous dehiscence defect, has been described according to the extent of the buccal bone plate absence. The literature has offered different techniques in the treatment of Type 2 sockets; however, the extent of the defect has never been defined or delineated. In this article, the authors describe a subclassification of Type 2 sockets: Type 2A presents with a dehiscence defect roughly 5 mm to 6 mm from the free gingival margin (FGM) involving the coronal one-third of the labial bone plate; Type 2B presents with a dehiscence defect involving the middle one-third of the labial plate, approximately 7 mm to 9 mm from the FGM; and in Type 2C the dehiscence defect involves the apical one-third of the labial osseous plate roughly 10 mm or greater from the FGM. The authors also offer a protocol and technique employing immediate implant placement, guided bone regeneration, and bone graft containment with a custom two-piece healing abutment that can lead to consistent and satisfactory clinical outcomes in low-smile-line patients. The treatment protocol and sequence is outlined in a clinical case presentation involving a Type 2B socket.
Lee, Jungwon; Park, Dueun; Koo, Ki-Tae; Seol, Yang-Jo; Lee, Yong-Moo
2018-04-03
This review aimed to investigate the feasibility of immediate implant placement in infected extraction sockets. We performed electronic and manual searches up to March 2017 to obtain data from randomized controlled trials (RCTs) and nonrandomized controlled clinical trials (CCTs). Using a fixed-effects model to assess the difference in survival rate (primary outcome), we evaluated the risk difference for immediate implant placement in infected and non-infected sites. We estimated the weighted mean differences (WMDs) of the change in marginal bone loss (MBL), probing depth (PD), modified bleeding index (mBI), marginal gingival level (MGL) and width of keratinized gingiva (WKG) at baseline and latest follow-up. In total, five studies (0 RCT, five CCTs) were included in the systematic review and three studies were included in the meta-analysis. The risk difference for immediate implant placement in an infected extraction socket compared with that in a non-infected socket was -0.02. WMDs for MBL, PD, mBI, MGL and WKG between the two groups were 0.32, 0.12, 0.07, -0.06, 0.20 and 0.51, respectively. No statistical differences were observed between the two groups, except for the change in WKG. Implants can be placed in infected extraction sockets after thorough socket debridement. For aesthetics, WKG should be considered when performing immediate implant placement in infected sites.
Tomasi, Cristiano; Donati, Mauro; Cecchinato, Denis; Szathvary, Isacco; Corrà, Enrico; Lindhe, Jan
2018-05-01
To examine if (i) characteristics of the fresh extraction socket site influenced subsequent dimensional alterations and (ii) placement of deproteinized bovine mineral in the socket affected volumetric change during healing. Twenty seven subjects and 28 extraction sites were included. Immediately after the removal of the tooth and after 6 months of healing, stone and virtual models of the jaw were produced. A cone beam computerized tomography scan was obtained immediately after extraction and the thickness of the buccal bone wall at the extraction site was measured. Extraction sites were randomly assigned to test or control group. In the test group, extraction sockets were filled with deproteinized bone mineral and covered with a collagen membrane. In the control group, only a collagen membrane was placed. The thickness of the buccal bone wall at the extraction site influenced the amount of volume reduction that occurred. Socket grafting influenced the degree of ridge diminution only at sites where the buccal bone wall was thin (≤ 1 mm). A graft comprised of collagen-enriched deproteinized bovine bone mineral, placed to fill extraction sockets failed to influence the overall diminution of the ridge that occurred during healing. The thickness of the buccal bone wall apparently had a significant influence on volumetric alterations of the edentulous ridge following tooth extraction. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
A pressure and shear sensor system for stress measurement at lower limb residuum/socket interface.
Laszczak, P; McGrath, M; Tang, J; Gao, J; Jiang, L; Bader, D L; Moser, D; Zahedi, S
2016-07-01
A sensor system for measurement of pressure and shear at the lower limb residuum/socket interface is described. The system comprises of a flexible sensor unit and a data acquisition unit with wireless data transmission capability. Static and dynamic performance of the sensor system was characterised using a mechanical test machine. The static calibration results suggest that the developed sensor system presents high linearity (linearity error ≤ 3.8%) and resolution (0.9 kPa for pressure and 0.2 kPa for shear). Dynamic characterisation of the sensor system shows hysteresis error of approximately 15% for pressure and 8% for shear. Subsequently, a pilot amputee walking test was conducted. Three sensors were placed at the residuum/socket interface of a knee disarticulation amputee and simultaneous measurements were obtained during pilot amputee walking test. The pressure and shear peak values as well as their temporal profiles are presented and discussed. In particular, peak pressure and shear of approximately 58 kPa and 27 kPa, respectively, were recorded. Their temporal profiles also provide dynamic coupling information at this critical residuum/socket interface. These preliminary amputee test results suggest strong potential of the developed sensor system for exploitation as an assistive technology to facilitate socket design, socket fit and effective monitoring of lower limb residuum health. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.
Bramanti, Ennio; Norcia, Antonio; Cicciù, Marco; Matacena, Giada; Cervino, Gabriele; Troiano, Giuseppe; Zhurakivska, Khrystyna; Laino, Luigi
2018-06-01
The aim of this randomized controlled trial was to evaluate the survival rate, the marginal bone level, and the aesthetic outcome; at 3 years' follow-up, of dental implants placed into a high-esthetic aesthetic zone by comparing 2 techniques of postextraction implant with immediate loading: the socket shied technique and the conventional insertion technique.Several clinical studies suggested that the avulsion of a dental element causes dimensional alterations of both soft and hard tissues at the postextractive site. To increase the aesthetic outcomes, the "socket-shield technique" has been proposed. This method involves maintaining the vestibular root portion and immediate insertion of the dental implant in close proximity to the root.Patients enrolled in this study were randomized to receive a postextraction implant in the aesthetic zone, either with the socket shied technique or with the conventional insertion technique. Implant survival, marginal bone level, and the pink aesthetic score were the outcomes evaluated.Implant survival rate was 100% in both the groups at 3 years. Implants inserted with the socket shield technique showed better values of both marginal bone level and pink aesthetic score (P < 0.05).Although such preliminary results need to be further confirmed, the socket shield technique seems to be a safe surgical technique that allows an implant rehabilitation characterized by better aesthetic outcomes.
Fickl, Stefan; Schneider, David; Zuhr, Otto; Hinze, Marc; Ender, Andreas; Jung, Ronald E; Hürzeler, Markus B
2009-05-01
The aim of the study was to volumetrically assess alterations of the ridge contour after socket preservation and buccal overbuilding. In five beagle dogs, four extraction sites were subjected to one of the following treatments: Tx 1: The socket was filled with BioOss Collagen and covered with a free gingival autograft from the palate (SP). Tx 2: The buccal bone plate was forced into a buccal direction using a manual bone spreader and SP was performed. Tx 3: The buccal bone plate was forced into a buccal direction using a manual bone spreader; SP was performed. Tx 4: The socket was filled with BioOss Collagen and a combined free gingival/connective tissue graft was used to cover the socket and for buccal tissue augmentation. Impressions were obtained at baseline, 2 weeks and 4 months post-operatively. Casts were optically scanned and superimposed in one common coordinate system. Using digital image analysis, the volumetric differences per area among the different treatment time points and among the treatment groups were calculated. Four months after tooth extraction, no statistically significant differences with regard to the buccal volume per area could be assessed among the treatment groups. Overbuilding the buccal aspect in combination with socket preservation is not a suitable technique to compensate for the alterations after tooth extraction.
Socket with built-in valves for the interconnection of microfluidic chips to macro constituents.
Yang, Zhen; Maeda, Ryutaro
2003-09-26
This paper reports a prototype for a standard connector between a microfluidic chip and the macro world. This prototype demonstrate a fully functioning socket for a microchip to access the outside world by means of fluids, data signals and energy supply. It supports up to 10 channels for the input and output of liquids or gases, as well as compressed air or vacuum lines for pneumatic power lines. The socket has built-in valves for each flow channel. It also contains 28 pins for the connection of electrical signals and power. Built-in valves make it possible to control the flow in each channel independently. A chip ( 11.0 x 11.0 x 0.9 mm) can be mounted into or dismounted from the socket with one touch. The fluidic connectors of the socket are designed to contact vertically on the top of chip. And the electrical connectors (the spring array) of that physically support the chip and contact lead pads at the bottom of chip. No adhesives or solders are used at any contact points. The pressure limit for the connection of working fluids was 0.2 MPa and the current limit for the electrical connections was 1 A. This socket supports both serial and parallel processing applications. It exhibits great potential for developing microfluidic systems efficiently.
Flexible session management in a distributed environment
NASA Astrophysics Data System (ADS)
Miller, Zach; Bradley, Dan; Tannenbaum, Todd; Sfiligoi, Igor
2010-04-01
Many secure communication libraries used by distributed systems, such as SSL, TLS, and Kerberos, fail to make a clear distinction between the authentication, session, and communication layers. In this paper we introduce CEDAR, the secure communication library used by the Condor High Throughput Computing software, and present the advantages to a distributed computing system resulting from CEDAR's separation of these layers. Regardless of the authentication method used, CEDAR establishes a secure session key, which has the flexibility to be used for multiple capabilities. We demonstrate how a layered approach to security sessions can avoid round-trips and latency inherent in network authentication. The creation of a distinct session management layer allows for optimizations to improve scalability by way of delegating sessions to other components in the system. This session delegation creates a chain of trust that reduces the overhead of establishing secure connections and enables centralized enforcement of system-wide security policies. Additionally, secure channels based upon UDP datagrams are often overlooked by existing libraries; we show how CEDAR's structure accommodates this as well. As an example of the utility of this work, we show how the use of delegated security sessions and other techniques inherent in CEDAR's architecture enables US CMS to meet their scalability requirements in deploying Condor over large-scale, wide-area grid systems.
... of the joint, is called the condyle. The socket is called the articular fossa. Between the condyle ... that is located between the jawbone and the socket. A displaced disk may produce clicking or popping ...
Cordasco, Frank A
2018-05-01
I believe that the distal femoral approach for anterior cruciate ligament reconstruction in the skeletally immature athlete with 3 to 6 years of remaining growth is best performed with an all-inside, all-epiphyseal technique using sockets rather than an outside-in approach creating tunnels. A shorter socket rather than a longer tunnel exposes a smaller surface area of the lateral distal femoral physis to potential compromise and resultant valgus malalignment. In addition, exiting the lateral femoral aspect of the epiphysis with a full-diameter tunnel as compared with a smaller diameter drill hole used to prepare a socket places the posterior articular cartilage, the lateral collateral ligament and anterolateral ligament footprints, and the popliteus tendon insertion at risk. My preference for sockets is also related to my belief that they provide a superior biologic milieu for graft incorporation compared with a full-length tunnel with the attendant violation of the lateral femoral cortex of the epiphysis. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
The efficacy of hyaluronic acid in postextraction sockets of impacted third molars: A pilot study.
Yilmaz, N; Demirtas, N; Kazancioglu, H O; Bayer, S; Acar, A H; Mihmanli, A
2017-12-01
This study aims to evaluate the effectiveness of local hyaluronic acid (HA) administration to surgically remove impacted third molar sockets and measure pain, swelling, and trismus. The study included a total of 25 healthy patients aged 18-29 years with asymptomatic bilaterally impacted lower third molars. All cases have been performed under local anesthesia. In the study group, 0.8% HA (Gengigel®) was applied in the postextraction sockets of the right third molars and in the control group nothing was applied to the extraction sockets of the left third molars. Postoperative pain, trismus, and swelling were evaluated on the 1st, 3rd, and 7th postoperative days. No difference was determined between groups in facial swelling and maximum mouth opening. However, the amount of pain significantly reduced in HA groups according to visual analog scale (P = 0.001). The results of this study showed that HA can produce an analgesic action in postextraction sockets after surgical removal of impacted teeth and therefore it has a clinical benefit to reduce usage of nonsteroidal anti-inflammatory drugs after dentoalveolar surgery.
Hamada, Yusuke; Prabhu, Srividya; John, Vanchit
2016-01-01
As implant therapy becomes more commonplace in daily practice, preservation and preparation of edentulous sites are key. Many times, however, implant therapy may not be considered at the time of tooth extraction and additional measures are not taken to conserve the edentulous site. While the healing process in extraction sockets has been well investigated and bone fill can be expected, there are cases where even when clinicians perform thorough debridement of the sockets, connective tissue infiltration into the socket can occur. This phenomenon, known as "erratic healing," may be associated with factors that lead to peri-implant disease and should be appropriately managed and treated prior to surgical implant placement. This case report describes the successful management of an erratic healing extraction socket in a 62-year-old Caucasian male patient with chronic periodontitis and the outcomes of an evidence-based treatment protocol performed prior to implant therapy. Careful preoperative analysis and cone beam computed tomography imaging can help detect signs of impaired healing in future implant sites and prevent surgical complications.
Prabhu, Srividya
2016-01-01
As implant therapy becomes more commonplace in daily practice, preservation and preparation of edentulous sites are key. Many times, however, implant therapy may not be considered at the time of tooth extraction and additional measures are not taken to conserve the edentulous site. While the healing process in extraction sockets has been well investigated and bone fill can be expected, there are cases where even when clinicians perform thorough debridement of the sockets, connective tissue infiltration into the socket can occur. This phenomenon, known as “erratic healing,” may be associated with factors that lead to peri-implant disease and should be appropriately managed and treated prior to surgical implant placement. This case report describes the successful management of an erratic healing extraction socket in a 62-year-old Caucasian male patient with chronic periodontitis and the outcomes of an evidence-based treatment protocol performed prior to implant therapy. Careful preoperative analysis and cone beam computed tomography imaging can help detect signs of impaired healing in future implant sites and prevent surgical complications. PMID:27807485
NASA Astrophysics Data System (ADS)
Tabik, S.; Romero, L. F.; Mimica, P.; Plata, O.; Zapata, E. L.
2012-09-01
A broad area in astronomy focuses on simulating extragalactic objects based on Very Long Baseline Interferometry (VLBI) radio-maps. Several algorithms in this scope simulate what would be the observed radio-maps if emitted from a predefined extragalactic object. This work analyzes the performance and scaling of this kind of algorithms on multi-socket, multi-core architectures. In particular, we evaluate a sharing approach, a privatizing approach and a hybrid approach on systems with complex memory hierarchy that includes shared Last Level Cache (LLC). In addition, we investigate which manual processes can be systematized and then automated in future works. The experiments show that the data-privatizing model scales efficiently on medium scale multi-socket, multi-core systems (up to 48 cores) while regardless of algorithmic and scheduling optimizations, the sharing approach is unable to reach acceptable scalability on more than one socket. However, the hybrid model with a specific level of data-sharing provides the best scalability over all used multi-socket, multi-core systems.
Kozmin, Stanislav G; Pavlov, Youri I; Kunkel, Thomas A; Sage, Evelyne
2003-08-01
Sunlight causes lesions in DNA that if unrepaired and inaccurately replicated by DNA polymerases yield mutations that result in skin cancer in humans. Two enzymes involved in translesion synthesis (TLS) of UV-induced photolesions are DNA polymerase eta (Poleta) and polymerase zeta (Polzeta), encoded by the RAD30A and REV3 genes, respectively. Previous studies have investigated the TLS roles of these polymerases in human and yeast cells irradiated with monochromatic, short wavelength UVC radiation (254 nm). However, less is known about cellular responses to solar radiation, which is of higher and mixed wavelengths (310-1100 nm) and produces a different spectrum of DNA lesions, including Dewar photoproducts and oxidative lesions. Here we report on the comparative cytotoxic and mutagenic effects of simulated sunlight (SSL) and UVC radiation on yeast wild-type, rad30Delta, rev3Delta and rev3Delta rad30Delta strains. The results with SSL support several previous interpretations on the roles of these two polymerases in TLS of photodimers and (6-4) photoproducts derived from studies with UVC. They further suggest that Poleta participates in the non-mutagenic bypass of SSL-dependent cytosine-containing Dewar photoproducts and 8-oxoguanine, while Polzeta is mainly responsible for the mutagenic bypass of all types of Dewar photoproducts. They also suggest that in the absence of Polzeta, Poleta contributes to UVC- and SSL-induced mutagenesis, possibly by the bypass of photodimers containing deaminated cytosine.
Holmer, Emil; Heimann, Mikael; Rudner, Mary
2016-01-01
Children with good phonological awareness (PA) are often good word readers. Here, we asked whether Swedish deaf and hard-of-hearing (DHH) children who are more aware of the phonology of Swedish Sign Language, a language with no orthography, are better at reading words in Swedish. We developed the Cross-modal Phonological Awareness Test (C-PhAT) that can be used to assess PA in both Swedish Sign Language (C-PhAT-SSL) and Swedish (C-PhAT-Swed), and investigated how C-PhAT performance was related to word reading as well as linguistic and cognitive skills. We validated C-PhAT-Swed and administered C-PhAT-Swed and C-PhAT-SSL to DHH children who attended Swedish deaf schools with a bilingual curriculum and were at an early stage of reading. C-PhAT-SSL correlated significantly with word reading for DHH children. They performed poorly on C-PhAT-Swed and their scores did not correlate significantly either with C-PhAT-SSL or word reading, although they did correlate significantly with cognitive measures. These results provide preliminary evidence that DHH children with good sign language PA are better at reading words and show that measures of spoken language PA in DHH children may be confounded by individual differences in cognitive skills. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
... This type of implant is an artificial hip socket that is created by fitting a metal ball ... particles (ions) can get released into the hip socket and sometimes the bloodstream, causing cobalt toxicity. This ...
... the opening at the end of the shoulder blade, called the socket. This type of joint allows ... head. The socket part (glenoid) of your shoulder blade will be replaced with a smooth plastic shell ( ...
Vane segment support and alignment device
DOE Office of Scientific and Technical Information (OSTI.GOV)
McLaurin, L.D.; Sizemore, J.D.
1999-07-13
A support and alignment assembly for supporting and aligning a vane segment is provided. The support and alignment assembly comprises a torque plate which defines an opening for receiving an eccentric pin and a locking end member for receiving a lock socket member. An eccentric pin adjustably supported by the torque plate opening for supporting and aligning a vane segment is provided. A lock socket member adapted to securely receive the eccentric pin and rotated therewith, and adjustably engage the torque plate locking end is provided. The lock socket member receives the eccentric pin, such that when the eccentric pinmore » is adjusted to align the vane segment, the lock socket member engages the torque plate locking end to secure the vane segment in the desired position. 5 figs.« less
Consonni, Stefano; Viganò, Federico
2011-01-01
This article is part of a set of six coordinated papers reporting the main findings of a research project carried out by five Italian universities on "Material and energy recovery in Integrated Waste Management Systems (IWMS)". An overview of the project and a summary of the most relevant results can be found in the introductory article of the series. This paper describes the work related to the evaluation of mass and energy balances, which has consisted of three major efforts (i) development of a model for quantifying the energy content and the elemental compositions of the waste streams appearing in a IWMS; (ii) upgrade of an earlier model to predict the performances of Waste-to-Energy (WtE) plants; (iii) evaluation of mass and energy balances of all the scenarios and the recovery paths considered in the project. Results show that not only the amount of material available for energy recovery is significantly higher than the Unsorted Residual Waste (URW) left after Separate Collection (SC), because selection and recycling generate significant amounts of residues, but its heating value is higher than that of the original, gross waste. Therefore, the energy potential of what is left after recycling is always higher than the complement to 100% of the Source Separation Level (SSL). Also, increasing SSL has marginal effects on the potential for energy recovery: nearly doubling SSL (from 35% to 65%) reduces the energy potential only by one fourth. Consequently, even at high SSL energy recovery is a fundamental step of a sustainable waste management system. Variations of SSL do bring about variations of the composition, heating value and moisture content of the material fed to WtE plants, but these variations (i) are smaller than one can expect; (ii) have marginal effects on the performances of the WtE plant. These considerations suggest that the mere value of SSL is not a good indicator of the quality of the waste management system, nor of its energy and environmental outcome. Given the well-known dependence of the efficiency of steam power plants with their power output, the efficiency of energy recovery crucially depends on the size of the IWMS served by the WtE plant. A fivefold increase of the amount of gross waste handled in the IWMS (from 150,000 to 750,000 tons per year of gross waste) allows increasing the electric efficiencies of the WtE plant by about 6-7 percentage points (from 21-23% to 28.5% circa). Copyright © 2011 Elsevier Ltd. All rights reserved.
... top of the thighbone (femoral head) and its socket (acetabulum) in the pelvic bone. It can be ... hip, the femoral head rests comfortably in its socket. In babies with DDH, the femoral head moves ...