Sample records for soft tissue adhesion

  1. Development and characterization of a novel hydrogel adhesive for soft tissue applications

    NASA Astrophysics Data System (ADS)

    Sanders, Lindsey Kennedy

    With laparoscopic and robotic surgical techniques advancing, the need for an injectable surgical adhesive is growing. To be effective, surgical adhesives for internal organs require bulk strength and compliance to avoid rips and tears, and adhesive strength to avoid leakage at the application site, while not hindering the natural healing process. Although a number of tissue adhesives and sealants approved by the FDA for surgical use are currently available, attaining a useful balance in all of these qualities has proven difficult, particularly when considering applications involving highly expandable tissue, such as bladder and lung. The long-term goal of this project is to develop a hydrogel-based tissue adhesive that provides proper mechanical properties to eliminate the need for sutures in various soft tissue applications. Tetronic (BASF), a 4-arm poly(propylene oxide)-poly(ethylene oxide) (PPO-PEO) block copolymer, has been selected as the base material for the adhesive hydrogel system. Solutions of Tetronic T1107 can support reverse thermal gelation at physiological temperatures, which can be combined with covalent crosslinking to achieve a "tandem gelation" process making it ideal for use as a tissue adhesive. The objective of this doctoral thesis research is to improve the performance of the hydrogel based tissue adhesive developed previously by Cho and co-workers by applying a multi-functionalization of Tetronic. Specifically, this research aimed to improve bonding strength of Tetronic tissue adhesive using bi-functional modification, incorporate hemostatic function to the bi-functional Tetronic hydrogel, and evaluate the safety of bi-functional Tetronic tissue adhesive both in vitro and in vivo. In summary, we have developed a fast-curing, mechanically strong hemostatic tissue adhesive that can control blood loss in wet conditions during wound treatment applications (bladder, liver and muscle). Specifically, the bi-functional Tetronic adhesive (TAS) with a proper blend ratio may be used to achieve an accurate balance in bulk and tissue bond strengths, as well as the compliance and durability for expandable organ application, such as the bladder. Incorporation of chitosan expanded the utility of the bi-functional modified T1107 (TAS) adhesive to tissue wounds on highly vascularized organs (e.g., liver, kidney). Further, we demonstrated that the modified Tetronic adhesive is biocompatible and safe for treatment of small soft tissue wounds on rat's muscle using FDA requirements. The current findings helped our understanding of the material and mechanical properties of the modified Tetronic adhesive and ultimately progress the field of surgical adhesives and sealants by providing a tunable adhesive system for various internal soft tissue wound applications.

  2. A bio-inspired swellable microneedle adhesive for mechanical interlocking with tissue

    NASA Astrophysics Data System (ADS)

    Yang, Seung Yun; O'Cearbhaill, Eoin D.; Sisk, Geoffroy C.; Park, Kyeng Min; Cho, Woo Kyung; Villiger, Martin; Bouma, Brett E.; Pomahac, Bohdan; Karp, Jeffrey M.

    2013-04-01

    Achieving significant adhesion to soft tissues while minimizing tissue damage poses a considerable clinical challenge. Chemical-based adhesives require tissue-specific reactive chemistry, typically inducing a significant inflammatory response. Staples are fraught with limitations including high-localized tissue stress and increased risk of infection, and nerve and blood vessel damage. Here inspired by the endoparasite Pomphorhynchus laevis, which swells its proboscis to attach to its host’s intestinal wall, we have developed a biphasic microneedle array that mechanically interlocks with tissue through swellable microneedle tips, achieving ~3.5-fold increase in adhesion strength compared with staples in skin graft fixation, and removal force of ~4.5 N cm-2 from intestinal mucosal tissue. Comprising a poly(styrene)-block-poly(acrylic acid) swellable tip and non-swellable polystyrene core, conical microneedles penetrate tissue with minimal insertion force and depth, yet high adhesion strength in their swollen state. Uniquely, this design provides universal soft tissue adhesion with minimal damage, less traumatic removal, reduced risk of infection and delivery of bioactive therapeutics.

  3. A Bio-Inspired Swellable Microneedle Adhesive for Mechanical Interlocking with Tissue

    PubMed Central

    Yang, Seung Yun; O'Cearbhaill, Eoin D.; Sisk, Geoffroy C.; Park, Kyeng Min; Cho, Woo Kyung; Villiger, Martin; Bouma, Brett E.; Pomahac, Bohdan; Karp, Jeffrey M.

    2013-01-01

    Achieving significant adhesion to soft tissues while minimizing tissue damage poses a considerable clinical challenge. Chemical-based adhesives require tissue-specific reactive chemistry, typically inducing a significant inflammatory response. Staples are fraught with limitations including high-localized tissue stress and increased risk of infection, and nerve and blood vessel damage. Here, inspired by the endoparasite Pomphorhynchus laevis which swells its proboscis to attach to its host’s intestinal wall, we have developed a biphasic microneedle array that mechanically interlocks with tissue through swellable microneedle tips, achieving ~ 3.5 fold increase in adhesion strength compared to staples in skin graft fixation, and removal force of ~ 4.5 N/cm2 from intestinal mucosal tissue. Comprising a poly(styrene)-block-poly(acrylic acid) swellable tip and non-swellable polystyrene core, conical microneedles penetrate tissue with minimal insertion force and depth, yet high adhesion strength in their swollen state. Uniquely, this design provides universal soft tissue adhesion with minimal damage, less traumatic removal, reduced risk of infection and delivery of bioactive therapeutics. PMID:23591869

  4. Summaries of Research - Fiscal Year 1985.

    DTIC Science & Technology

    1986-01-01

    emergencies, not trauma-related, 2) diagnosis of dental emergencies, trauma-related, 3) differential diagnosis of soft tissue lesions, 4) definitions of terms...on 49 different soft tissue lesions. Preliminary validation was accomplished by a variety of dentists who input over 200 simulated emergencies. The...non-specific opsonin, that promotes adhesion of fibroblasts to collagen, and influences the attachment of bacteria to soft tissues . As a first step

  5. Characterizing Adhesion between a Micropatterned Surface and a Soft Synthetic Tissue.

    PubMed

    Kern, Madalyn D; Qi, Yuan; Long, Rong; Rentschler, Mark E

    2017-01-31

    The work of adhesion and work of separation are characteristic properties of a contact interface that describe the amount of energy per unit area required to adhere or separate two contacting substrates, respectively. In this work, the authors present experimental and data analysis procedures that allow the contact interface between a soft synthetic tissue and a smooth or micropatterned poly(dimethylsiloxane) (PDMS) substrate to be characterized in terms of these characteristic parameters. Because of physical geometry limitations, the experimental contact geometry chosen for this study differs from conventional test geometries. Therefore, the authors used finite element modeling to develop correction factors specific to the experimental contact geometry used in this work. A work of adhesion was directly extracted from experimental data while the work of separation was estimated on the basis of experimental results. These values are compared to other theoretical calculations for validation. The results of this work indicate that the micropatterned PDMS substrate significantly decreases both the work of adhesion and work of separation as compared to a smooth PDMS substrate when in contact with a soft synthetic tissue substrate.

  6. Tunable denture adhesives using biomimetic principles for enhanced tissue adhesion in moist environments.

    PubMed

    Gill, Simrone K; Roohpour, Nima; Topham, Paul D; Tighe, Brian J

    2017-11-01

    Nature provides many interesting examples of adhesive strategies. Of particular note, the protein glue secreted by marine mussels delivers high adhesion in wet and dynamic environments owing to existence of catechol moieties. As such, this study focuses on denture fixatives, where a non-zinc-containing commercial-based formulation has been judiciously modified by a biomimetic catechol-inspired polymer, poly(3,4-dihydroxystyrene/styrene-alt-maleic acid) in a quest to modulate adhesive performance. In vitro studies, in a lap-shear configuration, revealed that the catechol-modified components were able to enhance adhesion to both the denture base and hydrated, functional oral tissue mimic, with the resulting mode of failure prominently being adhesive rather than cohesive. These characteristics are desirable in prosthodontic fixative applications, for which temporary adhesion must be maintained, with ultimately an adhesive failure from the mucosal tissue surface preferred. These insights provide an experimental platform in the design of future biomimetic adhesive systems. Mussel adhesive proteins have proven to be promising biomimetic adhesive candidates for soft tissues and here for the first time we have adapted marine adhesive technology into a denture fixative application. Importantly, we have incorporated a soft tissue mimic in our in vitro adhesion technique that more closely resembles the oral mucosa than previously studied substrates. The novel biomimetic-modified adhesives showed the ability to score the highest adhesive bonding out of all the formulations included in this study, across all moisture levels. This paper will be of major interest to the Acta Biomaterialia readership since the study has illustrated the potential of biomimetic principles in the design of effective prosthodontic tissue adhesives in a series of purpose-designed in vitro experiments in the context of the challenging features of the oral environment. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  7. Mechanical Characterization of a Bi-functional Tetronic Hydrogel Adhesive for Soft Tissues

    PubMed Central

    Sanders, Lindsey; Stone, Roland; Webb, C. Kenneth; Mefford, O. Thompson; Nagatomi, Jiro

    2014-01-01

    Although a number of tissue adhesives and sealants for surgical use are currently available, attaining a useful balance in high strength, high compliance, and low swelling has proven difficult. Recent studies have demonstrated that a 4-arm poly(propylene oxide)-poly(ethylene oxide) (PPO-PEO) block copolymer, Tetronic, can be chemically modified to form a hydrogel tissue adhesive21–23. Building on the success of these studies, the present study explored bi-functionalization of Tetronic with acrylates for chemical crosslinking of the hydrogel and N-hydroxysuccinimide (NHS) for reaction with tissue amines. The adhesive bond strengths of various uni- and bi-functional Tetronic blends (T1107 ACR: T1107 ACR/NHS) determined by lap shear testing ranged between 8 and 74 kPa, with the 75:25 (T1107 ACR: T1107 ACR/NHS) blend displaying the highest value. These results indicated that addition of NHS led to improvement of tissue bond strength over acrylation alone Furthermore, ex vivo pressure tests using the rat bladder demonstrated that the bi-functional Tetronic adhesive exhibited high compliance and maintained pressures under hundreds of filling and emptying cycles. Together, the results of the present study provided evidence that the bi-functional Tetronic adhesive with a proper blend ratio may be used to achieve an accurate balance in bulk and tissue bond strengths, as well as the compliance and durability for soft tissue such as the bladder. PMID:25111445

  8. Manual Physical Therapy for Non-Surgical Treatment of Adhesion-Related Small Bowel Obstructions: Two Case Reports

    PubMed Central

    Rice, Amanda D.; King, Richard; Reed, Evette D’Avy; Patterson, Kimberley; Wurn, Belinda F.; Wurn, Lawrence J.

    2013-01-01

    Background: Adhesion formation is a widely acknowledged risk following abdominal or pelvic surgery. Adhesions in the abdomen or pelvis can cause or contribute to partial or total small bowel obstruction (SBO). These adhesions deter or prevent the passage of nutrients through the digestive tract, and may bind the bowel to the peritoneum, or other organs. Small bowel obstructions can quickly become life-threatening, requiring immediate surgery to resect the bowel, or lyse any adhesions the surgeon can safely access. Bowel repair is an invasive surgery, with risks including bowel rupture, infection, and peritonitis. An additional risk includes the formation of new adhesions during the healing process, creating the potential for subsequent adhesiolysis or SBO surgeries. Objective: Report the use of manual soft tissue physical therapy for the reversal of adhesion-related partial SBOs, and create an initial inquiry into the possibility of nonsurgical lysis of adhesions. Case Reports: Two patients presenting with SBO symptoms due to abdominal adhesions secondary to abdominal and pelvic surgery were treated with manual soft tissue physical therapy focused on decreasing adhesions. Conclusions: Successful treatment with resolution of symptom presentation of partial SBO and sustained results were observed in both patients treated. PMID:26237678

  9. Hybrid Carbon-Based Scaffolds for Applications in Soft Tissue Reconstruction

    PubMed Central

    Lafdi, Khalid; Joseph, Robert M.; Tsonis, Panagiotis A.

    2012-01-01

    Current biomedical scaffolds utilized in surgery to repair soft tissues commonly fail to meet the optimal combination of biomechanical and tissue regenerative properties. Carbon is a scaffold alternative that potentially optimizes the balance between mechanical strength, durability, and function as a cell and biologics delivery vehicle that is necessary to restore tissue function while promoting tissue repair. The goals of this study were to investigate the feasibility of fabricating hybrid fibrous carbon scaffolds modified with biopolymer, polycaprolactone and to analyze their mechanical properties and ability to support cell growth and proliferation. Environmental scanning electron microscopy, micro-computed tomography, and cell adhesion and cell proliferation studies were utilized to test scaffold suitability as a cell delivery vehicle. Mechanical properties were tested to examine load failure and elastic modulus. Results were compared to an acellular dermal matrix scaffold control (GraftJacket® [GJ] Matrix), selected for its common use in surgery for the repair of soft tissues. Results indicated that carbon scaffolds exhibited similar mechanical maximums and capacity to support fibroblast adhesion and proliferation in comparison with GJ. Fibroblast adhesion and proliferation was collinear with carbon fiber orientation in regions of sparsely distributed fibers and occurred in clusters in regions of higher fiber density and low porosity. Overall, fibroblast adhesion and proliferation was greatest in lower porosity carbon scaffolds with highly aligned fibers. Stepwise multivariate regression showed that the variability in maximum load of carbon scaffolds and controls were dependent on unique and separate sets of parameters. These finding suggested that there were significant differences in the functional implications of scaffold design and material properties between carbon and dermis derived scaffolds that affect scaffold utility as a tissue replacement construct. PMID:22092333

  10. Novel on-demand bioadhesion to soft tissue in wet environments.

    PubMed

    Mogal, Vishal; Papper, Vladislav; Chaurasia, Alok; Feng, Gao; Marks, Robert; Steele, Terry

    2014-04-01

    Current methods of tissue fixation rely on mechanical-related technologies developed from the clothing and carpentry industries. Herein, a novel bioadhesive method that allows tuneable adhesion and is also applicable to biodegradable polyester substrates is described. Diazirine is the key functional group that allows strong soft tissue crosslinking and on-demand adhesion based on a free radical mechanism. Plasma post-irradiation grafting makes it possible to graft diazirine onto PLGA substrates. When the diazirine-PLGA films, placed on wetted ex vivo swine aortas, are activated with low intensity UV light, lap shear strength of up to 450 ± 50 mN cm(-2) is observed, which is one order of magnitude higher than hydrogel bioadhesives placed on similar soft tissues. The diazirine-modified PLGA thin films could be added on top of previously developed technologies for minimally invasive surgeries. The present work is focused on the chemistry, grafting, and lap shear strength of the alkyl diazirine-modified PLGA bioadhesive films. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Evaluation of hydrogels for soft tissue adhesives in vitro and in vivo analyses

    NASA Astrophysics Data System (ADS)

    Yuan, Liu; Fan, Wenshuai; Han, Linyingjun; Guo, Changan; Yan, Zuoqin; Zhu, Meifang; Mo, Xiumei

    2018-03-01

    In this study, natural materials (sodium alginate, dextran, gelatin and carboxymethyl chitosan) were modified to get aldehyde components and amino components. Upon mixing the two-component solutions together, four kinds of Schiff base hydrogels formed successfully within 5-300 s and could seal the wound tissue. The cytotoxicity tests of hydrogel extraction solution confirmed that the hydrogels are nontoxic materials. The adhesive ability was evaluated in vivo by measuring the adhesive strength after sealing the skin incisions on the back of rats. All the hydrogels showed higher adhesive strength than that of commercial fibrin glue and the blank control. The histological staining observation by hematoxylin and eosin staining (HE) and Masson's trichrome staining (MTC) methods suggested that the hydrogels had good biocompatibility and biodegradation in vivo. They have only normal initial inflammation to skin tissue and could improve the formation of new collagen in the incision section. So, the prepared hydrogels were both safe and effective tissue adhesive, which had the great potentials to be used as skin tissue adhesive.

  12. Dental fragment embedded in the lower lip after facial trauma: Brief review literature and report of a case

    PubMed Central

    Lauritano, Dorina; Petruzzi, Massimo; Sacco, Gerardo; Campus, Guglielmo; Carinci, Francesco; Milillo, Lucio

    2012-01-01

    Upper incisors are the most frequently involved teeth in traumatic dental injuries. Soft tissues (lips and/or oral mucosa) adjacent to incisal edge can receive direct and/or indirect traumas. Laceration of the lower lip is a not rare eventuality and teeth fragments could be embedded in labial soft tissue. The reattachment of these fragments, if possible, is the elective treatment choice, thanks to the modern adhesive and restorative techniques. The authors present a case of a white Caucasian 10-year-old child, who attended the dental clinic for the treatment of both upper central incisors’ crown fractures. The fragment of the left incisor was retrieved embedded in the lower lip. It was successfully surgically removed and reattached using a composite adhesive technique. A careful clinical and radiographic examination with the surgical removal of tooth fragments could prevent undesirable foreign body reaction, infection and scarring. The authors also reviewed the most relevant literature concerning tooth fragment reattachment after removal from oral soft tissues. PMID:23814592

  13. A naturally occurring nanomaterial from the Sundew (Drosera) for tissue engineering.

    PubMed

    Lenaghan, S C; Serpersu, K; Xia, L; He, W; Zhang, M

    2011-12-01

    In recent years advances have been made in the design of novel materials for tissue engineering through the use of polysaccharides. This study evaluated the ability of a naturally secreted polysaccharide adhesive from the Sundew (Drosera capensis) as a support for cell growth. The Sundew adhesive has several advantages including its high elasticity and antibiotic nature. By coating glass cover slips with the Sundew adhesive, a network of nanofibers was generated that was capable of promoting attachment and differentiation of a model neuronal cell line, PC-12. We also demonstrated the potential of this material for repairing bone and soft tissue injuries, by testing attachment of osteoblasts and endothelial cells. Finally, it was determined that the Sundew biomaterial was stable through testing by atomic force microscopy and prolonged cell growth. This work has proven the capabilities of using a nanomaterial derived from the Sundew adhesive for the purpose of tissue engineering.

  14. Soft tissue cell adhesion to titanium abutments after different cleaning procedures: Preliminary results of a randomized clinical trial

    PubMed Central

    Canullo, Luigi; Peñarrocha-Oltra, David; Marchionni, Silvia; Bagán, Leticia; Micarelli, Costanza

    2014-01-01

    Objectives: A randomized controlled trial was performed to assess soft tissue cell adhesion to implant titanium abutments subjected to different cleaning procedures and test if plasma cleaning can enhance cell adhesion at an early healing time. Study Design: Eighteen patients with osseointegrated and submerged implants were included. Before re-opening, 18 abutments were divided in 3 groups corresponding to different clinical conditions with different cleaning processes: no treatment (G1), laboratory customization and cleaning by steam (G2), cleaning by plasma of Argon (G3). Abutments were removed after 1 week and scanning electron microscopy was used to analyze cell adhesion to the abutment surface quantitatively (percentage of area occupied by cells) and qualitatively (aspect of adhered cells and presence of contaminants). Results: Mean percentages of area occupied by cells were 17.6 ± 22.7%, 16.5 ± 12.9% and 46.3 ± 27.9% for G1, G2 and G3 respectively. Differences were statistically significant between G1 and G3 (p=0.030), close to significance between G2 and G3 (p=0.056), and non-significant between G1 and G2 (p=0.530). The proportion of samples presenting adhered cells was homogeneous among the 3 groups (p-valor = 1.000). In all cases cells presented a flattened aspect; in 2 cases cells were less efficiently adhered and in 1 case cells presented filipodia. Three cases showed contamination with cocobacteria. Conclusions: Within the limits of the present study, plasma of Argon may enhance cell adhesion to titanium abutments, even at the early stage of soft tissue healing. Further studies with greater samples are necessary to confirm these findings. Key words:Connective tissue, dental abutments, randomized controlled trial, clinical research, glow discharged abutment, plasma cleaning. PMID:24121917

  15. Influence of Four Different Abutment Materials and the Adhesive Joint of Two-Piece Abutments on Cervical Implant Bone and Soft Tissue.

    PubMed

    Mehl, Christian; Gassling, Volker; Schultz-Langerhans, Stephan; Açil, Yahya; Bähr, Telse; Wiltfang, Jörg; Kern, Matthias

    The main aim of this study was to evaluate the influence of four different abutment materials and the adhesive joint of two-piece abutments on the cervical implant bone and soft tissue. Sixty-four titanium implants (Camlog Conelog; 4.3 ± 9 mm) were placed bone level into the edentulous arches of four minipigs. Four different types of abutments were placed at implant exposure: zirconium dioxide, lithium disilicate, and titanium bonded to a titanium luting base with resin cement; one-piece titanium abutments served as the control. The animals were sacrificed 6 months after implant exposure, and the bone-to-implant contact (BIC) area, sulcus depth, the length of the junctional epithelium and the connective tissue, the biologic width, and first cervical BIC-implant shoulder distance were measured using histomorphometry and light and fluorescence microscopy. Overall, 14 implants were lost (22%). At exposure, the implant shoulder-bone distance was 0.6 ± 0.7 mm. Six months later, the bone loss was 2.1 ± 1.2 mm measured histomorphometrically. There was a significant difference between the two measurements (P ≤ .0001). No significant influence could be found between any of the abutment materials with regard to bone loss or soft tissue anatomy (P > .05), with the exception of zirconium dioxide and onepiece titanium abutments when measuring the length of the junctional epithelium (P ≤ .01). The maxilla provided significantly more soft tissue and less bone loss compared with the mandible (P ≤ .02). All tested abutment materials and techniques seem to be comparable with regard to soft tissue properties and the cervical bone level.

  16. Epidemiologic study of soft tissue rheumatism in Shantou and Taiyuan, China.

    PubMed

    Zeng, Qing-yu; Zang, Chang-hai; Lin, Ling; Chen, Su-biao; Li, Xiao-feng; Xiao, Zheng-yu; Dong, Hai-yuan; Zhang, Ai-lian; Chen, Ren

    2010-08-05

    Soft tissue rheumatism is a group of common rheumatic disorders reported in many countries. For investigating the prevalence rate of soft tissue rheumatism in different population in China, we carried out a population study in Shantou rural and Taiyuan urban area. Samples of 3915 adults in an urban area of Taiyuan, Shanxi Province, and 2350 in a rural area of Shantou, Guangdong Province were surveyed. Modified International League of Association for Rheumatology (ILAR)-Asia Pacific League of Association for Rheumatology (APLAR) Community Oriented Program for Control of Rheumatic Diseases (COPCORD) core questionnaire was implemented as screening tool. The positive responders were then all examined by rheumatologists. Prevalence rate of soft tissue rheumatism was 2.0% in Taiyuan, and 5.3% in Shantou. Rotator cuff (shoulder) tendinitis, adhesive capsulitis (frozen shoulder), lateral epicondylitis (tennis elbow), and digital flexor tenosynovitis (trigger finger) were the commonly seen soft tissue rheumatism in both areas. Tatarsalgia, plantar fasciitis, and De Quervain's tenosynovitis were more commonly seen in Shantou than that in Taiyuan. Only 1 case of fibromyalgia was found in Taiyuan and 2 cases in Shantou. The prevalence of soft tissue rheumatism varied with age, sex and occupation. Soft tissue rheumatism is common in Taiyuan and Shantou, China. The prevalence of soft tissue rheumatism was quite different with different geographic, environmental, and socioeconomic conditions; and varying with age, sex, and occupation. The prevalence of fibromyalgia is low in the present survey.

  17. Biology of soft tissue wound healing and regeneration--consensus report of Group 1 of the 10th European Workshop on Periodontology.

    PubMed

    Hämmerle, Christoph H F; Giannobile, William V

    2014-04-01

    The scope of this consensus was to review the biological processes of soft tissue wound healing in the oral cavity and to histologically evaluate soft tissue healing in clinical and pre-clinical models. To review the current knowledge regarding the biological processes of soft tissue wound healing at teeth, implants and on the edentulous ridge. Furthermore, to review soft tissue wound healing at these sites, when using barrier membranes, growth and differentiation factors and soft tissue substitutes. Searches of the literature with respect to recessions at teeth and soft tissue deficiencies at implants, augmentation of the area of keratinized tissue and soft tissue volume were conducted. The available evidence was collected, categorized and summarized. Oral mucosal and skin wound healing follow a similar pattern of the four phases of haemostasis, inflammation, proliferation and maturation/matrix remodelling. The soft connective tissue determines the characteristics of the overlaying oral epithelium. Within 7-14 days, epithelial healing of surgical wounds at teeth is completed. Soft tissue healing following surgery at implants requires 6-8 weeks for maturation. The resulting tissue resembles scar tissue. Well-designed pre-clinical studies providing histological data have been reported describing soft tissue wound healing, when using barrier membranes, growth and differentiation factors and soft tissue substitutes. Few controlled clinical studies with low numbers of patients are available for some of the treatments reviewed at teeth. Whereas, histological new attachment has been demonstrated in pre-clinical studies resulting from some of the treatments reviewed, human histological data commonly report a lack of new attachment but rather long junctional epithelial attachment and connective tissue adhesion. Regarding soft tissue healing at implants human data are very scarce. Oral soft tissue healing at teeth, implants and the edentulous ridge follows the same phases as skin wound healing. Histological studies in humans have not reported new attachment formation at teeth for the indications studied. Human histological data of soft tissue wound healing at implants are limited. The use of barriers membranes, growth and differentiation factors and soft tissue substitutes for the treatment of localized gingival/mucosal recessions, insufficient amount of keratinized tissue and insufficient soft tissue volume is at a developing stage. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Biocompatibility study of lithium disilicate and zirconium oxide ceramics for esthetic dental abutments

    PubMed Central

    2016-01-01

    Purpose The increasing demand for esthetically pleasing results has contributed to the use of ceramics for dental implant abutments. The aim of this study was to compare the biological response of epithelial tissue cultivated on lithium disilicate (LS2) and zirconium oxide (ZrO2) ceramics. Understanding the relevant physicochemical and mechanical properties of these ceramics will help identify the optimal material for facilitating gingival wound closure. Methods Both biomaterials were prepared with 2 different surface treatments: raw and polished. Their physicochemical characteristics were analyzed by contact angle measurements, scanning white-light interferometry, and scanning electron microscopy. An organotypic culture was then performed using a chicken epithelium model to simulate peri-implant soft tissue. We measured the contact angle, hydrophobicity, and roughness of the materials as well as the tissue behavior at their surfaces (cell migration and cell adhesion). Results The best cell migration was observed on ZrO2 ceramic. Cell adhesion was also drastically lower on the polished ZrO2 ceramic than on both the raw and polished LS2. Evaluating various surface topographies of LS2 showed that increasing surface roughness improved cell adhesion, leading to an increase of up to 13%. Conclusions Our results demonstrate that a biomaterial, here LS2, can be modified using simple surface changes in order to finely modulate soft tissue adhesion. Strong adhesion at the abutment associated with weak migration assists in gingival wound healing. On the same material, polishing can reduce cell adhesion without drastically modifying cell migration. A comparison of LS2 and ZrO2 ceramic showed that LS2 was more conducive to creating varying tissue reactions. Our results can help dental surgeons to choose, especially for esthetic implant abutments, the most appropriate biomaterial as well as the most appropriate surface treatment to use in accordance with specific clinical dental applications. PMID:28050314

  19. Effect of nanoporous TiO2 coating and anodized Ca2+ modification of titanium surfaces on early microbial biofilm formation

    PubMed Central

    2011-01-01

    Background The soft tissue around dental implants forms a barrier between the oral environment and the peri-implant bone and a crucial factor for long-term success of therapy is development of a good abutment/soft-tissue seal. Sol-gel derived nanoporous TiO2 coatings have been shown to enhance soft-tissue attachment but their effect on adhesion and biofilm formation by oral bacteria is unknown. Methods We have investigated how the properties of surfaces that may be used on abutments: turned titanium, sol-gel nanoporous TiO2 coated surfaces and anodized Ca2+ modified surfaces, affect biofilm formation by two early colonizers of the oral cavity: Streptococcus sanguinis and Actinomyces naeslundii. The bacteria were detected using 16S rRNA fluorescence in situ hybridization together with confocal laser scanning microscopy. Results Interferometry and atomic force microscopy revealed all the surfaces to be smooth (Sa ≤ 0.22 μm). Incubation with a consortium of S. sanguinis and A. naeslundii showed no differences in adhesion between the surfaces over 2 hours. After 14 hours, the level of biofilm growth was low and again, no differences between the surfaces were seen. The presence of saliva increased the biofilm biovolume of S. sanguinis and A. naeslundii ten-fold compared to when saliva was absent and this was due to increased adhesion rather than biofilm growth. Conclusions Nano-topographical modification of smooth titanium surfaces had no effect on adhesion or early biofilm formation by S. sanguinis and A. naeslundii as compared to turned surfaces or those treated with anodic oxidation in the presence of Ca2+. The presence of saliva led to a significantly greater biofilm biovolume but no significant differences were seen between the test surfaces. These data thus suggest that modification with sol-gel derived nanoporous TiO2, which has been shown to improve osseointegration and soft-tissue healing in vivo, does not cause greater biofilm formation by the two oral commensal species tested than the other surfaces. PMID:21385428

  20. A soft tissue adhesive based on aldehyde-sodium alginate and amino-carboxymethyl chitosan preparation through the Schiff reaction

    NASA Astrophysics Data System (ADS)

    Wu, Yu; Yuan, Liu; Sheng, Nai-an; Gu, Zi-qi; Feng, Wen-hao; Yin, Hai-yue; Morsi, Yosry; Mo, Xiu-mei

    2017-09-01

    Sodium alginate and carboxymethyl chitosan have been extensively applied in tissue engineering and other relative fields due to their low price and excellent biocompatibility. In this paper, we oxidized sodium alginate with sodium periodate to convert 1,2-hydroxyl groups into aldehyde groups to get aldehyde-sodium alginate (ASA). Carboxymethyl chitosan was modified with ethylenediamine (ED) in the presence of water-soluble N-(3-Dimethylaminopropyl)-N'-ethylcarbodiimide hydrochloride (EDC) to introduce additional amino groups to get amino-carboxymethyl chitosan (A-CS). Upon mixing the A-SA and A-CS aqueous solutions together, a gel rapidly formed based on the Schiff's base reaction between aldehyde groups in A-SA and amino groups in A-CS. FTIR analysis confirmed the characteristic peak of Schiff's base group in the hydrogel. It was confirmed that the gelation time be dependent on the aldehyde group content in A-SA and amino group content in A-CS. The fasted hydrogel formation takes place within 10 min. The data of bonding strength and cytotoxicity measurement also showed that the hydrogel had good adhesion and biocompatibility. All these results support that this gel has the potential as soft tissue adhesive.

  1. Study on biphasic material model and mechanical analysis of knee joint cartilage

    NASA Astrophysics Data System (ADS)

    Nakatani, A.; Sakashita, A.

    2008-02-01

    A material model of articular cartilage is formulated, and fundamental problems are analyzed. The soft tissue is assumed to comprise two phases: solid and fluid. The biphasic theory proposed by Spilker and Suh (1990) to deal with such materials is reviewed, and some new additional analyses are carried out on the basis of this theory. Assuming the elasticity for the solid phase and introducing the pressure, which is defined by the product of the volume change and penalty coefficient, it is shown that the viscoelastic property of the soft tissue can be reproduced. A preferable solution is obtained for the solid phase by using the reduction integral, even if a high-order interpolation function is used. However, the high-order element cannot satisfactorily capture the velocity distribution of fluids. The pressure distribution is studied by assuming the change in the surface characteristics of the cartilage tissue with the progress of osteoarthritis. The pressure is strongly related to the lubrication conditions, i.e., perfect lubrication, perfect adhesion, and partial adhesion.

  2. Role of cell deformability in the two-dimensional melting of biological tissues

    NASA Astrophysics Data System (ADS)

    Li, Yan-Wei; Ciamarra, Massimo Pica

    2018-04-01

    The size and shape of a large variety of polymeric particles, including biological cells, star polymers, dendrimes, and microgels, depend on the applied stresses as the particles are extremely soft. In high-density suspensions these particles deform as stressed by their neighbors, which implies that the interparticle interaction becomes of many-body type. Investigating a two-dimensional model of cell tissue, where the single particle shear modulus is related to the cell adhesion strength, here we show that the particle deformability affects the melting scenario. On increasing the temperature, stiff particles undergo a first-order solid/liquid transition, while soft ones undergo a continuous solid/hexatic transition followed by a discontinuous hexatic/liquid transition. At zero temperature the melting transition driven by the decrease of the adhesion strength occurs through two continuous transitions as in the Kosterlitz, Thouless, Halperin, Nelson, and Young scenario. Thus, there is a range of adhesion strength values where the hexatic phase is stable at zero temperature, which suggests that the intermediate phase of the epithelial-to-mesenchymal transition could be hexatic type.

  3. Bio-inspired enhancement of friction and adhesion at the polydimethylsiloxane-intestine interface and biocompatibility characterization.

    PubMed

    Zhang, Hongyu; Wang, Yi; Vasilescu, Steven; Gu, Zhibin; Sun, Tao

    2017-05-01

    An active navigation of self-propelled miniaturized robot along the intestinal tract without injuring the soft tissue remains a challenge as yet. Particularly in this case an effective control of the interfacial friction and adhesion between the material used and the soft tissue is crucial. In the present study, we investigated the frictional and adhesive properties between polydimethylsiloxane (PDMS, microscopically patterned with micro-pillar arrays and non-patterned with a flat surface) and rabbit small intestinal tract using a universal material tester. The friction coefficient-time plot and adhesive force-time plot were recorded during the friction test (sliding speed: 0.25mm/s; normal loading: 0.4N) and adhesion test (preloading: 0.5N; hoisting speed: 2.5×10 -3 mm/s). In addition, biocompatibility of the PDMS samples was characterized in terms of cell morphology (scanning electron microscope) and cell cytotoxicity (alamarBlue assay) using human vascular endothelial cells (HUVECs). The results demonstrated that the interfacial friction (0.27 vs 0.19) and adhesion (34.9mN vs 26.7mN) were greatly increased using microscopically patterned PDMS, in comparison with non-patterned PDMS. HUVECs adhered to and proliferated on non-patterned/microscopically patterned PDMS very well, with a relative cell viability of about 90% following seeding at 1d, 3d, and 5d. The favorable enhancement of the frictional and adhesive properties, along with the excellent biocompatibility of the microscopically patterned PDMS, makes it a propitious choice for clinical application of self-propelled miniaturized robots. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Science, Technology and Requirements - Forum

    DTIC Science & Technology

    2012-10-18

    Visable Absorbing and Electrostatically Adhesive Taggants •2008 Removal of CBRN Materials from Soil & Water using Nanosize Hydroxyapaptite •2009...Ribbon Composite for Optically Transparent Armor Windows •2010 UV Retroreflector Covert Taggants •2013 Proposed Warfighter Bandaging System Company... Bandaging System - Proposed Properties: •Bioactive fiber tissue scaffolding (bonds to both hard and soft tissue) •Hemostatic and Bioresorbable

  5. Histatin 1 Enhances Cell Adhesion to Titanium in an Implant Integration Model.

    PubMed

    van Dijk, I A; Beker, A F; Jellema, W; Nazmi, K; Wu, G; Wismeijer, D; Krawczyk, P M; Bolscher, J G M; Veerman, E C I; Stap, J

    2017-04-01

    Cellular adhesion is essential for successful integration of dental implants. Rapid soft tissue integration is important to create a seal around the implant and prevent infections, which commonly cause implant failure and can result in bone loss. In addition, soft tissue management is important to obtain good dental aesthetics. We previously demonstrated that the salivary peptide histatin 1 (Hst1) causes a more than 2-fold increase in the ability of human adherent cells to attach and spread on a glass surface. Cells treated with Hst1 attached more rapidly and firmly to the substrate and to each other. In the current study, we examine the potential application of Hst1 for promotion of dental implant integration. Our results show that Hst1 enhances the attachment and spreading of soft tissue cell types (oral epithelial cells and fibroblasts) to titanium (Ti) and hydroxyapatite (HAP), biomaterials that have found wide applications as implant material in dentistry and orthopedics. For improved visualization of cell adhesion to Ti, we developed a novel technique that uses sputtering to deposit a thin, transparent layer of Ti onto glass slides. This approach allows detailed, high-resolution analysis of cell adherence to Ti in real time. Furthermore, our results suggest that Hst1 has no negative effects on cell survival. Given its natural occurrence in the oral cavity, Hst1 could be an attractive agent for clinical application. Importantly, even though Hst1 is specific for saliva of humans and higher primates, it stimulated the attachment and spreading of canine cells, paving the way for preclinical studies in canine models.

  6. Mechanically robust cryogels with injectability and bioprinting supportability for adipose tissue engineering.

    PubMed

    Qi, Dianjun; Wu, Shaohua; Kuss, Mitchell A; Shi, Wen; Chung, Soonkyu; Deegan, Paul T; Kamenskiy, Alexey; He, Yini; Duan, Bin

    2018-05-26

    Bioengineered adipose tissues have gained increased interest as a promising alternative to autologous tissue flaps and synthetic adipose fillers for soft tissue augmentation and defect reconstruction in clinic. Although many scaffolding materials and biofabrication methods have been investigated for adipose tissue engineering in the last decades, there are still challenges to recapitulate the appropriate adipose tissue microenvironment, maintain volume stability, and induce vascularization to achieve long-term function and integration. In the present research, we fabricated cryogels consisting of methacrylated gelatin, methacrylated hyaluronic acid, and 4arm poly(ethylene glycol) acrylate (PEG-4A) by using cryopolymerization. The cryogels were repeatedly injectable and stretchable, and the addition of PEG-4A improved the robustness and mechanical properties. The cryogels supported human adipose progenitor cell (HWA) and adipose derived mesenchymal stromal cell adhesion, proliferation, and adipogenic differentiation and maturation, regardless of the addition of PEG-4A. The HWA laden cryogels facilitated the co-culture of human umbilical vein endothelial cells (HUVEC) and capillary-like network formation, which in return also promoted adipogenesis. We further combined cryogels with 3D bioprinting to generate handleable adipose constructs with clinically relevant size. 3D bioprinting enabled the deposition of multiple bioinks onto the cryogels. The bioprinted flap-like constructs had an integrated structure without delamination and supported vascularization. Adipose tissue engineering is promising for reconstruction of soft tissue defects, and also challenging for restoring and maintaining soft tissue volume and shape, and achieving vascularization and integration. In this study, we fabricated cryogels with mechanical robustness, injectability, and stretchability by using cryopolymerization. The cryogels promoted cell adhesion, proliferation, and adipogenic differentiation and maturation of human adipose progenitor cells and adipose derived mesenchymal stromal cells. Moreover, the cryogels also supported 3D bioprinting on top, forming vascularized adipose constructs. This study demonstrates the potential of the implementation of cryogels for generating volume-stable adipose tissue constructs and provides a strategy to fabricate vascularized flap-like constructs for complex soft tissue regeneration. Copyright © 2018. Published by Elsevier Ltd.

  7. Properties of pressure-sensitive adhesive tapes with soft adhesives to human skin and their mechanism.

    PubMed

    Tokumura, Fumio; Homma, Takeyasu; Tomiya, Toshiki; Kobayashi, Yuko; Matsuda, Tetsuaki

    2007-05-01

    The use of soft adhesives in the manufacture of pressure-sensitive adhesive tapes has recently increased. The dermal peeling force of adhesive tapes with soft adhesives was studied. Four kinds of adhesive tapes with adhesives of different softness were made, by adding varying amounts of isopropyl myristate as a softener. The tapes were applied on the flexor side of the forearm of six healthy male volunteers. The dermal peeling force, the amount of stripped corneocytes, the level of pain when the tapes were removed and the degree of penetration of adhesives into the sulcus cutis (skin furrows) were evaluated at 1 and 24 h after application of the tapes. Furthermore, a skin model panel (a sulcus cutis and crista cutis model panel) and a crista cutis model panel were constructed from a general stainless-steel panel, and the peeling force of the tapes against the model panels was measured. As the softness of adhesives increased, the peeling force against a general stainless-steel panel with a flat surface decreased, although the peeling force against human skin did not significantly change. The amount of stripped corneocytes on the removed tapes and the level of pain when the tapes were removed decreased with the increase in softness of the adhesives. These results suggest that adhesive tapes with soft adhesives that contain isopropyl myristate as a softener are suitable for the skin. Furthermore, the degree of penetration of adhesive into the sulcus cutis increased as the softness of adhesives increased. Upon evaluation of the peeling force against the model panels, as the softness of adhesives increased, there was a slight decrease in the peeling force against the skin model panel, while there was a remarkable decrease in the peeling force against the crista cutis model panel. These results suggest that the lack of change in the dermal peeling force as the softness of adhesives increased was caused by penetration of soft adhesive into the sulcus cutis, and that the decrease in the amount of stripped corneocytes was caused by a decrease in the peeling force against the crista cutis, which consists of corneocytes mainly removed by the tapes.

  8. CMG2 Expression Is an Independent Prognostic Factor for Soft Tissue Sarcoma Patients

    PubMed Central

    Wedler, Alice; Rot, Swetlana; Keßler, Jacqueline; Kehlen, Astrid; Holzhausen, Hans-Jürgen; Bache, Matthias; Würl, Peter; Kappler, Matthias

    2017-01-01

    The capillary morphogenesis gene 2 (CMG2), also known as the anthrax toxin receptor 2 (ANTXR2), is a transmembrane protein putatively involved in extracellular matrix (ECM) adhesion and tissue remodeling. CMG2 promotes endothelial cell proliferation and exhibits angiogenic properties. Its downregulation is associated with a worsened survival of breast carcinoma patients. Aim of this study was to analyze the CMG2 mRNA and protein expression in soft tissue sarcoma and their association with patient outcome. CMG2 mRNA was measured in 121 tumor samples of soft tissue sarcoma patients using quantitative real-time PCR. CMG2 protein was evaluated in 52 tumor samples by ELISA. CMG2 mRNA was significantly correlated with the corresponding CMG2 protein expression (rs = 0.31; p = 0.027). CMG2 mRNA expression was associated with the mRNA expressions of several ECM and tissue remodeling enzymes, among them CD26 and components of the uPA system. Low CMG2 mRNA expression was correlated with a worsened patients’ disease-specific survival in Kaplan-Meier analyses (mean patient survival was 25 vs. 96 months; p = 0.013), especially in high-stage tumors. A decreased CMG2 expression is a negative prognostic factor for soft tissue sarcoma patients. CMG2 may be an interesting candidate gene for the further exploration of soft tissue sarcoma genesis and progression. PMID:29215551

  9. CMG2 Expression Is an Independent Prognostic Factor for Soft Tissue Sarcoma Patients.

    PubMed

    Greither, Thomas; Wedler, Alice; Rot, Swetlana; Keßler, Jacqueline; Kehlen, Astrid; Holzhausen, Hans-Jürgen; Bache, Matthias; Würl, Peter; Taubert, Helge; Kappler, Matthias

    2017-12-07

    The capillary morphogenesis gene 2 (CMG2), also known as the anthrax toxin receptor 2 (ANTXR2), is a transmembrane protein putatively involved in extracellular matrix (ECM) adhesion and tissue remodeling. CMG2 promotes endothelial cell proliferation and exhibits angiogenic properties. Its downregulation is associated with a worsened survival of breast carcinoma patients. Aim of this study was to analyze the CMG2 mRNA and protein expression in soft tissue sarcoma and their association with patient outcome. CMG2 mRNA was measured in 121 tumor samples of soft tissue sarcoma patients using quantitative real-time PCR. CMG2 protein was evaluated in 52 tumor samples by ELISA. CMG2 mRNA was significantly correlated with the corresponding CMG2 protein expression (r s = 0.31; p = 0.027). CMG2 mRNA expression was associated with the mRNA expressions of several ECM and tissue remodeling enzymes, among them CD26 and components of the uPA system. Low CMG2 mRNA expression was correlated with a worsened patients' disease-specific survival in Kaplan-Meier analyses (mean patient survival was 25 vs. 96 months; p = 0.013), especially in high-stage tumors. A decreased CMG2 expression is a negative prognostic factor for soft tissue sarcoma patients. CMG2 may be an interesting candidate gene for the further exploration of soft tissue sarcoma genesis and progression.

  10. Laminin active peptide/agarose matrices as multifunctional biomaterials for tissue engineering.

    PubMed

    Yamada, Yuji; Hozumi, Kentaro; Aso, Akihiro; Hotta, Atsushi; Toma, Kazunori; Katagiri, Fumihiko; Kikkawa, Yamato; Nomizu, Motoyoshi

    2012-06-01

    Cell adhesive peptides derived from extracellular matrix components are potential candidates to afford bio-adhesiveness to cell culture scaffolds for tissue engineering. Previously, we covalently conjugated bioactive laminin peptides to polysaccharides, such as chitosan and alginate, and demonstrated their advantages as biomaterials. Here, we prepared functional polysaccharide matrices by mixing laminin active peptides and agarose gel. Several laminin peptide/agarose matrices showed cell attachment activity. In particular, peptide AG73 (RKRLQVQLSIRT)/agarose matrices promoted strong cell attachment and the cell behavior depended on the stiffness of agarose matrices. Fibroblasts formed spheroid structures on the soft AG73/agarose matrices while the cells formed a monolayer with elongated morphologies on the stiff matrices. On the stiff AG73/agarose matrices, neuronal cells extended neuritic processes and endothelial cells formed capillary-like networks. In addition, salivary gland cells formed acini-like structures on the soft matrices. These results suggest that the peptide/agarose matrices are useful for both two- and three-dimensional cell culture systems as a multifunctional biomaterial for tissue engineering. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Polyacylurethanes as Novel Degradable Cell Carrier Materials for Tissue Engineering

    PubMed Central

    Jovanovic, Danijela; Roukes, Frans V.; Löber, Andrea; Engels, Gerwin E.; van Oeveren, Willem; van Seijen, Xavier J. Gallego; van Luyn, Marja J.A.; Harmsen, Martin C.; Schouten, Arend Jan

    2011-01-01

    Polycaprolactone (PCL) polyester and segmented aliphatic polyester urethanes based on PCL soft segment have been thoroughly investigated as biodegradable scaffolds for tissue engineering. Although proven beneficial as long term implants, these materials degrade very slowly and are therefore not suitable in applications in which scaffold support is needed for a shorter time. A recently developed class of polyacylurethanes (PAUs) is expected to fulfill such requirements. Our aim was to assess in vitro the degradation of PAUs and evaluate their suitability as temporary scaffold materials to support soft tissue repair. With both a mass loss of 2.5–3.0% and a decrease in molar mass of approx. 35% over a period of 80 days, PAUs were shown to degrade via both bulk and surface erosion mechanisms. Fourier Transform Infra Red (FTIR) spectroscopy was successfully applied to study the extent of PAUs microphase separation during in vitro degradation. The microphase separated morphology of PAU1000 (molar mass of the oligocaprolactone soft segment = 1000 g/mol) provided this polymer with mechano-physical characteristics that would render it a suitable material for constructs and devices. PAU1000 exhibited excellent haemocompatibility in vitro. In addition, PAU1000 supported both adhesion and proliferation of vascular endothelial cells and this could be further enhanced by pre-coating of PAU1000 with fibronectin (Fn). The contact angle of PAU1000 decreased both with in vitro degradation and by incubation in biological fluids. In endothelial cell culture medium the contact angle reached 60°, which is optimal for cell adhesion. Taken together, these results support the application of PAU1000 in the field of soft tissue repair as a temporary degradable scaffold. PMID:28824103

  12. Thermal gelation and tissue adhesion of biomimetic hydrogels

    PubMed Central

    Burke, Sean A; Ritter-Jones, Marsha; Lee, Bruce P; Messersmith, Phillip B

    2008-01-01

    Marine and freshwater mussels are notorious foulers of natural and manmade surfaces, secreting specialized protein adhesives for rapid and durable attachment to wet substrates. Given the strong and water-resistant nature of mussel adhesive proteins, significant potential exists for mimicking their adhesive characteristics in bioinspired synthetic polymer materials. An important component of these proteins is L-3,4-dihydroxylphenylalanine (DOPA), an amino acid believed to contribute to mussel glue solidification through oxidation and crosslinking reactions. Synthetic polymers containing DOPA residues have previously been shown to crosslink into hydrogels upon the introduction of oxidizing reagents. Here we introduce a strategy for stimuli responsive gel formation of mussel adhesive protein mimetic polymers. Lipid vesicles with a bilayer melting transition of 37 °C were designed from a mixture of dipalmitoyl and dimyristoyl phosphatidylcholines and exploited for the release of a sequestered oxidizing reagent upon heating from ambient to physiologic temperature. Colorimetric studies indicated that sodium-periodate-loaded liposomes released their cargo at the phase transition temperature, and when used in conjunction with a DOPA-functionalized poly(ethylene glycol) polymer gave rise to rapid solidification of a crosslinked polymer hydrogel. The tissue adhesive properties of this biomimetic system were determined by in situ thermal gelation of liposome/polymer hydrogel between two porcine dermal tissue surfaces. Bond strength measurements showed that the bond formed by the adhesive hydrogel (mean = 35.1 kPa, SD = 12.5 kPa, n = 11) was several times stronger than a fibrin glue control tested under the same conditions. The results suggest a possible use of this biomimetic strategy for repair of soft tissues. PMID:18458476

  13. Controllable load sharing for soft adhesive interfaces on three-dimensional surfaces.

    PubMed

    Song, Sukho; Drotlef, Dirk-Michael; Majidi, Carmel; Sitti, Metin

    2017-05-30

    For adhering to three-dimensional (3D) surfaces or objects, current adhesion systems are limited by a fundamental trade-off between 3D surface conformability and high adhesion strength. This limitation arises from the need for a soft, mechanically compliant interface, which enables conformability to nonflat and irregularly shaped surfaces but significantly reduces the interfacial fracture strength. In this work, we overcome this trade-off with an adhesion-based soft-gripping system that exhibits enhanced fracture strength without sacrificing conformability to nonplanar 3D surfaces. Composed of a gecko-inspired elastomeric microfibrillar adhesive membrane supported by a pressure-controlled deformable gripper body, the proposed soft-gripping system controls the bonding strength by changing its internal pressure and exploiting the mechanics of interfacial equal load sharing. The soft adhesion system can use up to ∼26% of the maximum adhesion of the fibrillar membrane, which is 14× higher than the adhering membrane without load sharing. Our proposed load-sharing method suggests a paradigm for soft adhesion-based gripping and transfer-printing systems that achieves area scaling similar to that of a natural gecko footpad.

  14. Controllable load sharing for soft adhesive interfaces on three-dimensional surfaces

    NASA Astrophysics Data System (ADS)

    Song, Sukho; Drotlef, Dirk-Michael; Majidi, Carmel; Sitti, Metin

    2017-05-01

    For adhering to three-dimensional (3D) surfaces or objects, current adhesion systems are limited by a fundamental trade-off between 3D surface conformability and high adhesion strength. This limitation arises from the need for a soft, mechanically compliant interface, which enables conformability to nonflat and irregularly shaped surfaces but significantly reduces the interfacial fracture strength. In this work, we overcome this trade-off with an adhesion-based soft-gripping system that exhibits enhanced fracture strength without sacrificing conformability to nonplanar 3D surfaces. Composed of a gecko-inspired elastomeric microfibrillar adhesive membrane supported by a pressure-controlled deformable gripper body, the proposed soft-gripping system controls the bonding strength by changing its internal pressure and exploiting the mechanics of interfacial equal load sharing. The soft adhesion system can use up to ˜26% of the maximum adhesion of the fibrillar membrane, which is 14× higher than the adhering membrane without load sharing. Our proposed load-sharing method suggests a paradigm for soft adhesion-based gripping and transfer-printing systems that achieves area scaling similar to that of a natural gecko footpad.

  15. Controllable load sharing for soft adhesive interfaces on three-dimensional surfaces

    PubMed Central

    Song, Sukho; Drotlef, Dirk-Michael; Majidi, Carmel; Sitti, Metin

    2017-01-01

    For adhering to three-dimensional (3D) surfaces or objects, current adhesion systems are limited by a fundamental trade-off between 3D surface conformability and high adhesion strength. This limitation arises from the need for a soft, mechanically compliant interface, which enables conformability to nonflat and irregularly shaped surfaces but significantly reduces the interfacial fracture strength. In this work, we overcome this trade-off with an adhesion-based soft-gripping system that exhibits enhanced fracture strength without sacrificing conformability to nonplanar 3D surfaces. Composed of a gecko-inspired elastomeric microfibrillar adhesive membrane supported by a pressure-controlled deformable gripper body, the proposed soft-gripping system controls the bonding strength by changing its internal pressure and exploiting the mechanics of interfacial equal load sharing. The soft adhesion system can use up to ∼26% of the maximum adhesion of the fibrillar membrane, which is 14× higher than the adhering membrane without load sharing. Our proposed load-sharing method suggests a paradigm for soft adhesion-based gripping and transfer-printing systems that achieves area scaling similar to that of a natural gecko footpad. PMID:28507143

  16. Integrin-specific mechanoresponses to compression and extension probed by cylindrical flat-ended AFM tips in lung cells.

    PubMed

    Acerbi, Irene; Luque, Tomás; Giménez, Alícia; Puig, Marta; Reguart, Noemi; Farré, Ramon; Navajas, Daniel; Alcaraz, Jordi

    2012-01-01

    Cells from lung and other tissues are subjected to forces of opposing directions that are largely transmitted through integrin-mediated adhesions. How cells respond to force bidirectionality remains ill defined. To address this question, we nanofabricated flat-ended cylindrical Atomic Force Microscopy (AFM) tips with ~1 µm(2) cross-section area. Tips were uncoated or coated with either integrin-specific (RGD) or non-specific (RGE/BSA) molecules, brought into contact with lung epithelial cells or fibroblasts for 30 s to form focal adhesion precursors, and used to probe cell resistance to deformation in compression and extension. We found that cell resistance to compression was globally higher than to extension regardless of the tip coating. In contrast, both tip-cell adhesion strength and resistance to compression and extension were the highest when probed at integrin-specific adhesions. These integrin-specific mechanoresponses required an intact actin cytoskeleton, and were dependent on tyrosine phosphatases and Ca(2+) signaling. Cell asymmetric mechanoresponse to compression and extension remained after 5 minutes of tip-cell adhesion, revealing that asymmetric resistance to force directionality is an intrinsic property of lung cells, as in most soft tissues. Our findings provide new insights on how lung cells probe the mechanochemical properties of the microenvironment, an important process for migration, repair and tissue homeostasis.

  17. [A case of internal carotid artery stenosis with discontinuance of carotid endarterectomy due to the tight adhesions around the internal carotid artery].

    PubMed

    Kohri, Ryusuke; Miyazono, Masayuki; Hatae, Ryusuke; Maeda, Kazushi; Takahira, Asuka; Maeda, Yasuhiro; Mizota, Takamitsu; Naito, Shinji

    2012-05-01

    A 73-year-old female visited her local doctor after repeatedly experiencing temporary weakness in her left upper and lower extremities. The patient underwent a cervical magnetic resonance imaging (MRI) scan and was diagnosed with right internal carotid artery stenosis. Despite administration of antiplatelet drugs, her symptoms continued, and she was referred to our department for medical treatment. Her medical history revealed hypertension, hyperlipidemia, and cholesteatoma. We diagnosed symptomatic internal carotid artery stenosis and performed carotid endarterectomy (CEA). However, tight adhesions between the carotid artery and surrounding tissue made separation difficult, and surgery had to be discontinued. Some of the extracted adherent tissue consisted of hyalinized fibrous tissue that had the appearance of soft tissue which had organized because of inflammation. Although there have been no reports of cholesteatoma directly causing adhesion around the internal carotid artery, it has been reported to have led to abscess formation in the parapharyngeal space adjacent to the carotid space. Because the boundaries of the parapharyngeal space and carotid space are anatomically incomplete, inflammation often affects the area between them. As far as we know, this report, which also includes a discussion of the literature, is the first to indicate that cholesteatoma causes strong adhesions around the carotid artery.

  18. Tissue Cells Feel and Respond to the Stiffness of Their Substrate

    NASA Astrophysics Data System (ADS)

    Discher, Dennis E.; Janmey, Paul; Wang, Yu-li

    2005-11-01

    Normal tissue cells are generally not viable when suspended in a fluid and are therefore said to be anchorage dependent. Such cells must adhere to a solid, but a solid can be as rigid as glass or softer than a baby's skin. The behavior of some cells on soft materials is characteristic of important phenotypes; for example, cell growth on soft agar gels is used to identify cancer cells. However, an understanding of how tissue cells-including fibroblasts, myocytes, neurons, and other cell types-sense matrix stiffness is just emerging with quantitative studies of cells adhering to gels (or to other cells) with which elasticity can be tuned to approximate that of tissues. Key roles in molecular pathways are played by adhesion complexes and the actin-myosin cytoskeleton, whose contractile forces are transmitted through transcellular structures. The feedback of local matrix stiffness on cell state likely has important implications for development, differentiation, disease, and regeneration.

  19. Human fibrin tissue adhesive for sutureless lamellar keratoplasty and scleral patch adhesion: a pilot study.

    PubMed

    Kaufman, Herbert E; Insler, Michael S; Ibrahim-Elzembely, Hosan A; Kaufman, Stephen C

    2003-11-01

    To determine whether a fibrin adhesive can facilitate the performance of sutureless lamellar keratoplasty and attachment of amnion to bare sclera. Prospective, noncomparative case series. Six patients, 5 of whom underwent lamellar keratoplasty and 1 who received an amniotic patch of the sclera and cornea. Institutional review board approval was not required for these therapeutic treatments. In 5 patients, the epithelium was removed from the corneal surface, a free cap, 200- micro m thick, was cut with a microkeratome, and a human fibrin tissue adhesive (Tisseel VH Fibrin Sealant; Baxter Healthcare Corporation, Glendale, CA) was applied to the cut surface of the corneal stroma. A 200- micro m thick, microkeratome-cut lamellar graft was placed in the stromal bed without sutures, and a bandage soft contact lens was applied. The lens was left in place for 1 week and then removed. In 1 patient, the adhesive was applied to bare sclera for attachment of amniotic membrane after removal of a conjunctival melanosis. All patients were followed up for 3 months after surgery. Tissue adhesion, corneal clarity, and visual acuity. All 5 lamellar grafts healed and remained clear, although final visual acuity varied with visual potential and astigmatism. The amniotic membrane graft also adhered well to the bare sclera. The fibrin adhesive provided satisfactory attachment without sutures for lamellar keratoplasty and amniotic patching. It should be effective for sealing of clear cornea incisions, LASIK flaps, and conjunctival and skin grafts. An adhesive that has been designed specifically for ophthalmic applications and is more convenient to use would be desirable.

  20. Invadopodia formation in blood clots: Not so SLUGgish after all.

    PubMed

    Knowles, Lynn M; Maranchie, Jodi K; Pilch, Jan

    2014-01-01

    Blood clotting specifically supports the metastatic dissemination of malignant cells to the lung. We have recently demonstrated that 2 tumor types that are prone to form lung metastases, renal cell carcinoma and soft tissue sarcoma, share specific adhesive mechanisms that support the invasion and colonization of blood clots in the pulmonary vasculature.

  1. The effect of AlloDerm® on the initiation and growth of human neovessels.

    USDA-ARS?s Scientific Manuscript database

    AlloDerm® is commonly employed for reconstruction of ablative soft tissue and mucosal defects following surgical resections. Although devoid of growth factors, AlloDerm® may serve as an adhesive matrix for binding of growth factors increasing local angiogenesis and wound healing. We hypothesized tha...

  2. Polypyrrole/Alginate Hybrid Hydrogels: Electrically Conductive and Soft Biomaterials for Human Mesenchymal Stem Cell Culture and Potential Neural Tissue Engineering Applications.

    PubMed

    Yang, Sumi; Jang, LindyK; Kim, Semin; Yang, Jongcheol; Yang, Kisuk; Cho, Seung-Woo; Lee, Jae Young

    2016-11-01

    Electrically conductive biomaterials that can efficiently deliver electrical signals to cells or improve electrical communication among cells have received considerable attention for potential tissue engineering applications. Conductive hydrogels are desirable particularly for neural applications, as they can provide electrical signals and soft microenvironments that can mimic native nerve tissues. In this study, conductive and soft polypyrrole/alginate (PPy/Alg) hydrogels are developed by chemically polymerizing PPy within ionically cross-linked alginate hydrogel networks. The synthesized hydrogels exhibit a Young's modulus of 20-200 kPa. Electrical conductance of the PPy/Alg hydrogels could be enhanced by more than one order of magnitude compared to that of pristine alginate hydrogels. In vitro studies with human bone marrow-derived mesenchymal stem cells (hMSCs) reveal that cell adhesion and growth are promoted on the PPy/Alg hydrogels. Additionally, the PPy/Alg hydrogels support and greatly enhance the expression of neural differentiation markers (i.e., Tuj1 and MAP2) of hMSCs compared to tissue culture plate controls. Subcutaneous implantation of the hydrogels for eight weeks induces mild inflammatory reactions. These soft and conductive hydrogels will serve as a useful platform to study the effects of electrical and mechanical signals on stem cells and/or neural cells and to develop multifunctional neural tissue engineering scaffolds. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Surface characterization of retinal tissues for the enhancement of vitreoretinal surgical methods

    NASA Astrophysics Data System (ADS)

    Valentin-Rodriguez, Celimar

    Diabetic retinopathy is the most common ophthalmic complication of diabetes and the leading cause of blindness among adults, ages 30 to 70. Surgery to remove scar tissue in the eye is the only corrective treatment once the retina is affected. Visual recovery is often hampered by retinal trauma during surgery and by low patient compliance. Our work in this project aimed to improve vitreoretinal surgical methods from information gathered by sensitive surface analysis of pre-retinal tissues found at the vitreoretinal interface. Atomic force microscopy characterization of human retinal tissues revealed that surgically excised inner limiting membrane (ILM) has a heterogeneous surface and is mainly composed of globular and fibrous structures. ILM tissues also show low adhesion for clean unmodified surfaces as opposed to those with functional groups attractive to those on the ILM surface, due to their charge. Based on these observations, layer-by-layer films with embedded gold nanoparticles with a positive outer charge were designed. These modifications increased the adhesion between surgical instruments and ILM by increasing the roughness and tuning the film surface charge. These films proved to be stable under physiological conditions. Finally, the effect of vital dyes on the topographical characteristics of ILMs was characterized and new imaging modes to further reveal ILM topography were utilized. Roughness and adhesion force data suggest that second generation dyes have no effect on the surface nanostructure of ILMs, but increase adhesion at the tip sample interface. This project clearly illustrates that physicochemical information from tissues can be used to rationally re-design surgical procedures, in this case for tissue removal purposes. This rational design method can be applied to other soft tissue excision procedures as is the case of cataract surgery or laparoscopic removal of endometrial tissue.

  4. Basic components of connective tissues and extracellular matrix: elastin, fibrillin, fibulins, fibrinogen, fibronectin, laminin, tenascins and thrombospondins.

    PubMed

    Halper, Jaroslava; Kjaer, Michael

    2014-01-01

    Collagens are the most abundant components of the extracellular matrix and many types of soft tissues. Elastin is another major component of certain soft tissues, such as arterial walls and ligaments. Many other molecules, though lower in quantity, function as essential components of the extracellular matrix in soft tissues. Some of these are reviewed in this chapter. Besides their basic structure, biochemistry and physiology, their roles in disorders of soft tissues are discussed only briefly as most chapters in this volume deal with relevant individual compounds. Fibronectin with its muldomain structure plays a role of "master organizer" in matrix assembly as it forms a bridge between cell surface receptors, e.g., integrins, and compounds such collagen, proteoglycans and other focal adhesion molecules. It also plays an essential role in the assembly of fibrillin-1 into a structured network. Laminins contribute to the structure of the extracellular matrix (ECM) and modulate cellular functions such as adhesion, differentiation, migration, stability of phenotype, and resistance towards apoptosis. Though the primary role of fibrinogen is in clot formation, after conversion to fibrin by thrombin, it also binds to a variety of compounds, particularly to various growth factors, and as such fibrinogen is a player in cardiovascular and extracellular matrix physiology. Elastin, an insoluble polymer of the monomeric soluble precursor tropoelastin, is the main component of elastic fibers in matrix tissue where it provides elastic recoil and resilience to a variety of connective tissues, e.g., aorta and ligaments. Elastic fibers regulate activity of TGFβs through their association with fibrillin microfibrils. Elastin also plays a role in cell adhesion, cell migration, and has the ability to participate in cell signaling. Mutations in the elastin gene lead to cutis laxa. Fibrillins represent the predominant core of the microfibrils in elastic as well as non-elastic extracellular matrixes, and interact closely with tropoelastin and integrins. Not only do microfibrils provide structural integrity of specific organ systems, but they also provide a scaffold for elastogenesis in elastic tissues. Fibrillin is important for the assembly of elastin into elastic fibers. Mutations in the fibrillin-1 gene are closely associated with Marfan syndrome. Fibulins are tightly connected with basement membranes, elastic fibers and other components of extracellular matrix and participate in formation of elastic fibers. Tenascins are ECM polymorphic glycoproteins found in many connective tissues in the body. Their expression is regulated by mechanical stress both during development and in adulthood. Tenascins mediate both inflammatory and fibrotic processes to enable effective tissue repair and play roles in pathogenesis of Ehlers-Danlos, heart disease, and regeneration and recovery of musculo-tendinous tissue. One of the roles of thrombospondin 1 is activation of TGFβ. Increased expression of thrombospondin and TGFβ activity was observed in fibrotic skin disorders such as keloids and scleroderma. Cartilage oligomeric matrix protein (COMP) or thrombospondin-5 is primarily present in the cartilage. High levels of COMP are present in fibrotic scars and systemic sclerosis of the skin, and in tendon, especially with physical activity, loading and post-injury. It plays a role in vascular wall remodeling and has been found in atherosclerotic plaques as well.

  5. Use of tissue adhesive as a field expedient barrier dressing for hand wounds in disaster responders.

    PubMed

    Levy, Matthew J; Tang, Nelson

    2014-02-01

    Injuries sustained by disaster responders can impede the affected individuals' ability to perform critical functions and often require the redirection of already scarce resources. Soft-tissue injuries to the hand are commonly experienced by disaster workers and even seemingly mild lacerations can pose the potential for significant complications in such hazard-filled environments. In this report, the authors describe their experience utilizing tissue adhesive to create a functional and effective barrier dressing for a hand injury sustained by a responder at the West, Texas USA fertilizer plant explosion. This technique of wound management allowed the patient to continue performing essential onsite functions for a sustained period following the explosion and the subsequent investigative processes. At the 30-day follow-up, the wound was well healed and without complications. This technique proved to be a valuable method of field expedient wound management and is worthy of consideration in similar future circumstances.

  6. Flexible-Device Injector with a Microflap Array for Subcutaneously Implanting Flexible Medical Electronics.

    PubMed

    Song, Kwangsun; Kim, Juho; Cho, Sungbum; Kim, Namyun; Jung, Dongwuk; Choo, Hyuck; Lee, Jongho

    2018-06-25

    Implantable electronics in soft and flexible forms can reduce undesired outcomes such as irritations and chronic damages to surrounding biological tissues due to the improved mechanical compatibility with soft tissues. However, the same mechanical flexibility also makes it difficult to insert such implants through the skin because of reduced stiffness. In this paper, a flexible-device injector that enables the subcutaneous implantation of flexible medical electronics is reported. The injector consists of a customized blade at the tip and a microflap array which holds the flexible implant while the injector penetrates through soft tissues. The microflap array eliminates the need of additional materials such as adhesives that require an extended period to release a flexible medical electronic implant from an injector inside the skin. The mechanical properties of the injection system during the insertion process are experimentally characterized, and the injection of a flexible optical pulse sensor and electrocardiogram sensor is successfully demonstrated in vivo in live pig animal models to establish the practical feasibility of the concept. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. An evaluation of a silicone adhesive shaped heel dressing.

    PubMed

    Hampton, Sylvie

    Tissue breakdown is complex and involves many factors. Pressure ulcer development in the heels is subject to extrinsic factors such as pressure, shear, friction and moisture. The heels are the most common sites for friction and shear damage, which can lead to blistering, skin erosion and tissue breakdown (Grey et al, 2006). To address the issues of wounds that are painful on dressing removal and friable skin, Smith & Nephew has introduced a soft silicone adhesive dressing to its Allevyn dressing range. Silicone does not adhere to wounded areas and can be removed gently without trauma to the periwound area. This paper discusses the findings of a 20-patient multi-site evaluation examining the performance and acceptability of Allevyn Gentle Border Heel dressing in the management of heel wounds.

  8. Lyophilized Silk Sponges: A Versatile Biomaterial Platform for Soft Tissue Engineering

    PubMed Central

    2015-01-01

    We present a silk biomaterial platform with highly tunable mechanical and degradation properties for engineering and regeneration of soft tissues such as, skin, adipose, and neural tissue, with elasticity properties in the kilopascal range. Lyophilized silk sponges were prepared under different process conditions and the effect of silk molecular weight, concentration and crystallinity on 3D scaffold formation, structural integrity, morphology, mechanical and degradation properties, and cell interactions in vitro and in vivo were studied. Tuning the molecular weight distribution (via degumming time) of silk allowed the formation of stable, highly porous, 3D scaffolds that held form with silk concentrations as low as 0.5% wt/v. Mechanical properties were a function of silk concentration and scaffold degradation was driven by beta-sheet content. Lyophilized silk sponges supported the adhesion of mesenchymal stem cells throughout 3D scaffolds, cell proliferation in vitro, and cell infiltration and scaffold remodeling when implanted subcutaneously in vivo. PMID:25984573

  9. Soft grippers using micro-fibrillar adhesives for transfer printing.

    PubMed

    Song, Sukho; Sitti, Metin

    2014-07-23

    The adhesive characteristics of fibrillar adhesives on a soft deformable membrane are reported. A soft gripper with an inflatable membrane covered by elastomer mushroom-shaped microfibers have a superior conformation to non-planar 3D part geometries, enabling the transfer printing of various parts serially or in parallel. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Polymicrobial periodontal pathogens transcriptomes in calvarial bone and soft tissue

    PubMed Central

    Bakthavatchalu, Vasudevan; Meka, Archana; Mans, Jeffrey J.; Sathishkumar, Sabapathi; Lopez, M. Cecilia; Bhattacharyya, Indraneel; Boyce, Brendan F.; Baker, Henry V.; Lamont, Richard J.; Ebersole, Jeffrey L.; Kesavalu, L.

    2011-01-01

    Summary Porphyromonas gingivalis, Treponema denticola, and Tannerella forsythia are consistently associated with adult periodontitis. This study sought to document the host transcriptome to a P. gingivalis, T. denticola, and T. forsythia challenge as a polymicrobial infection using a murine calvarial model of acute inflammation and bone resorption. Mice were infected with P. gingivalis, T. denticola, and T. forsythia over the calvaria, after which the soft tissues and calvarial bones were excised. A Murine GeneChip® array analysis of transcript profiles showed that 6997 genes were differentially expressed in calvarial bones (P < 0.05) and 1544 genes were differentially transcribed in the inflamed tissues after the polymicrobial infection. Of these genes, 4476 and 1035 genes in the infected bone and tissues were differentially expressed by upregulation. Biological pathways significantly impacted by the polymicrobial infection in calvarial bone included leukocyte transendothelial migration (LTM), cell adhesion molecules, adherens junction, major histocompatibility complex antigen, extracellular matrix-receptor interaction (ECM), and antigen processing and presentation resulting in inflammatory/cytokine/chemokine transcripts stimulation in bone and soft tissue. Intense inflammation and increased activated osteoclasts was observed in calvarias compared to sham-infected controls. Quantitative real-time RT-PCR analysis confirmed mRNA level of selected genes corresponded with the microarray expression. The polymicrobial infection regulated several LTM and extracellular membrane (ECM) pathway genes in a manner distinct from monoinfection with P. gingivalis, T. denticola, or T. forsythia. To our knowledge, this is the first definition of the polymicrobial induced transcriptome in calvarial bone and soft tissue in response to periodontal pathogens. PMID:21896157

  11. Efficacy of hemostasis for epidural venous plexus and safety for neural structure using soft coagulation system in spinal surgery: a laboratory investigation using a porcine model.

    PubMed

    Nishida, Kotaro; Kakutani, Kenichiro; Maeno, Koichiro; Takada, Toru; Yurube, Takashi; Kuroda, Ryosuke; Kurosaka, Masahiro

    2013-10-01

    A laboratory investigation using porcine model. To clarify the effectiveness of the soft coagulation system for stopping bleeding from the epidural vein using different outputs and the safety in terms of tissue damage including spinal cord injury. Problems associated with coagulation using an electrosurgical device, such as carbonization of tissue or adhesion to the electrode, have been highlighted. So called "soft coagulation" has been developed to solve these problems. Its' utility as well as the safety of the neural structure in spine surgery has never been reported. A total of 3 animals and 45 spinal segments were used. Total laminectomy was performed to expose the dural tube and epidural venous plexus. Stable bleeding was induced by a 22 G needle puncture. Soft coagulation monopolar output (SCM), soft coagulation bipolar output (SCB), and conventional bipolar output (CB) were used as the coagulators. Valid hemostasis was defined as macroscopically complete bleeding stoppage by coagulation within 3 minutes. The neurological assessment was evaluated by somatosensory evoked potential. Histologic analysis was performed to determine the area of thermal damage. Valid hemostasis ratio was 75.0% of SCM group, 68.8% of SCB group, and 30.8% of CB group. Somatosensory evoked potential monitoring revealed that spinal cord injury was observed in 4 lesions (25%) of the SCM group. Neither bipolar groups (SCB and CB) showed any changes in waveform pattern. Histologic analysis revealed that severe thermal damages were observed in the epidural space of the SCM group. The usefulness of soft coagulation is revealed in terms of bleeding stoppage from epidural vessels and reduced soft-tissue damage compared with the conventional electric device. However, assessing the potential risk of severe neural tissue damage including spinal cord injury, a bipolar soft coagulation is strongly recommended for use in spine surgery.

  12. Pressure sensitive microparticle adhesion through biomimicry of the pollen-stigma interaction.

    PubMed

    Lin, Haisheng; Qu, Zihao; Meredith, J Carson

    2016-03-21

    Many soft biomimetic synthetic adhesives, optimized to support macroscopic masses (∼kg), have been inspired by geckos, insects and other animals. Far less work has investigated bioinspired adhesion that is tuned to micro- and nano-scale sizes and forces. However, such adhesive forces are extremely important in the adhesion of micro- and nanoparticles to surfaces, relevant to a wide range of industrial and biological systems. Pollens, whose adhesion is critical to plant reproduction, are an evolutionary-optimized system for biomimicry to engineer tunable adhesion between particles and micro-patterned soft matter surfaces. In addition, the adhesion of pollen particles is relevant to topics as varied as pollinator ecology, transport of allergens, and atmospheric phenomena. We report the first observation of structurally-derived pressure-sensitive adhesion of a microparticle by using the sunflower pollen and stigma surfaces as a model. This strong, pressure-sensitive adhesion results from interlocking between the pollen's conical spines and the stigma's receptive papillae. Inspired by this behavior, we fabricated synthetic polymeric patterned surfaces that mimic the stigma surface's receptivity to pollen. These soft mimics allow the magnitude of the pressure-sensitive response to be tuned by adjusting the size and spacing of surface features. These results provide an important new insight for soft material adhesion based on bio-inspired principles, namely that ornamented microparticles and micro-patterned surfaces can be designed with complementarity that enable a tunable, pressure-sensitive adhesion on the microparticle size and length scale.

  13. A modular reactor to simulate biofilm development in orthopedic materials.

    PubMed

    Barros, Joana; Grenho, Liliana; Manuel, Cândida M; Ferreira, Carla; Melo, Luís F; Nunes, Olga C; Monteiro, Fernando J; Ferraz, Maria P

    2013-09-01

    Surfaces of medical implants are generally designed to encourage soft- and/or hard-tissue adherence, eventually leading to tissue- or osseo-integration. Unfortunately, this feature may also encourage bacterial adhesion and biofilm formation. To understand the mechanisms of bone tissue infection associated with contaminated biomaterials, a detailed understanding of bacterial adhesion and subsequent biofilm formation on biomaterial surfaces is needed. In this study, a continuous-flow modular reactor composed of several modular units placed in parallel was designed to evaluate the activity of circulating bacterial suspensions and thus their predilection for biofilm formation during 72 h of incubation. Hydroxyapatite discs were placed in each modular unit and then removed at fixed times to quantify biofilm accumulation. Biofilm formation on each replicate of material, unchanged in structure, morphology, or cell density, was reproducibly observed. The modular reactor therefore proved to be a useful tool for following mature biofilm formation on different surfaces and under conditions similar to those prevailing near human-bone implants.

  14. Biophysical effects of repetitive removal of adhesive dressings on peri-ulcer skin.

    PubMed

    Zillmer, R; Agren, M S; Gottrup, F; Karlsmark, T

    2006-05-01

    To study the effect of repeated removal of four different adhesive dressings on peri-ulcer skin using quantitative non-invasive techniques. Forty-five patients with open (n = 29) or healed (n = 16) venous leg ulcers were included. Peri-ulcer skin was treated for 14 days with patches of two different hydrocolloid-based adhesive dressings, one polyurethane adhesive and one soft silicone adhesive dressing. Normal skin of the patients' ventral forearm was also treated identically. Adhesive patches of the dressings were replaced every second day. The skin barrier function was assessed by measuring transepidermal water loss and stratum corneum hydration by measuring electrical conductance. Thirty-nine patients completed the study. The hydrocolloid adhesives increased transepidermal water loss and conductance while the polyurethane and soft silicone adhesives did not influence these parameters significantly compared with adjacent non-treated peri-ulcer skin. For normal forearm skin, similar relative effects among the four adhesives were found. Repetitive treatment with hydrocolloid-based adhesive dressings induced major functional alterations of the stratum corneum. In contrast, a polyurethane adhesive and a soft silicone adhesive dressing did not alter transepidermal water loss or conductance of peri-ulcer skin.

  15. Directing stem cell fate on hydrogel substrates by controlling cell geometry, matrix mechanics and adhesion ligand composition.

    PubMed

    Lee, Junmin; Abdeen, Amr A; Zhang, Douglas; Kilian, Kristopher A

    2013-11-01

    There is a dynamic relationship between physical and biochemical signals presented in the stem cell microenvironment to guide cell fate determination. Model systems that modulate cell geometry, substrate stiffness or matrix composition have proved useful in exploring how these signals influence stem cell fate. However, the interplay between these physical and biochemical cues during differentiation remains unclear. Here, we demonstrate a microengineering strategy to vary single cell geometry and the composition of adhesion ligands - on substrates that approximate the mechanical properties of soft tissues - to study adipogenesis and neurogenesis in adherent mesenchymal stem cells. Cells cultured in small circular islands show elevated expression of adipogenesis markers while cells that spread in anisotropic geometries tend to express elevated neurogenic markers. Arraying different combinations of matrix protein in a myriad of 2D and pseudo-3D geometries reveals optimal microenvironments for controlling the differentiation of stem cells to these "soft" lineages without the use of media supplements. © 2013 Elsevier Ltd. All rights reserved.

  16. Establishing contact between cell-laden hydrogels and metallic implants with a biomimetic adhesive for cell therapy supported implants.

    PubMed

    Barthes, Julien; Mutschler, Angela; Dollinger, Camille; Gaudinat, Guillaume; Lavalle, Philippe; Le Houerou, Vincent; Brian McGuinness, Garrett; Engin Vrana, Nihal

    2017-12-15

    For in-dwelling implants, controlling the biological interface is a crucial parameter to promote tissue integration and prevent implant failure. For this purpose, one possibility is to facilitate the establishment of the interface with cell-laden hydrogels fixed to the implant. However, for proper functioning, the stability of the hydrogel on the implant should be ensured. Modification of implant surfaces with an adhesive represents a promising strategy to promote the adhesion of a cell-laden hydrogel on an implant. Herein, we developed a peptidic adhesive based on mussel foot protein (L-DOPA-L-lysine) 2 -L-DOPA that can be applied directly on the surface of an implant. At physiological pH, unoxidized (L-DOPA-L-lysine) 2 -L-DOPA was supposed to strongly adhere to metallic surfaces but it only formed a very thin coating (less than 1 nm). Once oxidized at physiological pH, (L-DOPA-L-lysine) 2 -L-DOPA forms an adhesive coating about 20 nm thick. In oxidized conditions, L-lysine can adhere to metallic substrates via electrostatic interaction. Oxidized L-DOPA allows the formation of a coating through self-polymerization and can react with amines so that this adhesive can be used to fix extra-cellular matrix based materials on implant surfaces through the reaction of quinones with amino groups. Hence, a stable interface between a soft gelatin hydrogel and metallic surfaces was achieved and the strength of adhesion was investigated. We have shown that the adhesive is non-cytotoxic to encapsulated cells and enabled the adhesion of gelatin soft hydrogels for 21 days on metallic substrates in liquid conditions. The adhesion properties of this anchoring peptide was quantified by a 180° peeling test with a more than 60% increase in peel strength in the presence of the adhesive. We demonstrated that by using a biomimetic adhesive, for the application of cell-laden hydrogels to metallic implant surfaces, the hydrogel/implant interface can be ensured without relying on the properties of the deposited biomaterials.

  17. Silicon Carbide Nanoparticles as an Effective Bioadhesive to Bond Collagen Containing Composite Gel Layers for Tissue Engineering Applications.

    PubMed

    Attalla, Rana; Ling, Celine S N; Selvaganapathy, Ponnambalam Ravi

    2018-03-01

    Additive manufacturing via layer-by-layer adhesive bonding holds much promise for scalable manufacturing of tissue-like constructs, specifically scaffolds with integrated vascular networks for tissue engineering applications. However, there remains a lack of effective adhesives capable of composite layer fusion without affecting the integrity of patterned features. Here, the use of silicon carbide is introduced as an effective adhesive to achieve strong bonding (0.39 ± 0.03 kPa) between hybrid hydrogel films composed of alginate and collagen. The techniques have allowed us to fabricate multilayered, heterogeneous constructs with embedded high-resolution microchannels (150 µm-1 mm) that are precisely interspaced (500-600 µm). Hydrogel layers are effectively bonded with silicon carbide nanoparticles without blocking the hollow microchannels and high cell viability (90.61 ± 3.28%) is maintained within the scaffold. Nanosilica is also tested and found to cause clogging of smaller microchannels when used for interlayer bonding, but is successfully used to attach synthetic polymers (e.g., Tygon) to the hydrogels (32.5 ± 2.12 mN bond strength). This allows us to form inlet and outlet interconnections to the gel constructs. This ability to integrate hollow channel networks into bulk soft material structures for perfusion can be useful in 3D tissue engineering applications. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Incremental Value of Magnetic Resonance Imaging in Further Characterizing Hypodense Mediastinal and Paracardiac Lesions Identified on Computed Tomography

    PubMed Central

    Chaturvedi, Abhishek; Gange, Chris; Sahin, Hakan; Chaturvedi, Apeksha

    2018-01-01

    Mediastinal and paracardiac lesions are usually first diagnosed on a chest radiograph or echocardiogram. Often, a computed tomography is obtained to further delineate these lesions. CT may be suboptimal for evaluation of enhancement characteristics and direct extension into the adjacent mediastinal structures. With its intrinsic superior soft-tissue characterization, magnetic resonance imaging (MRI) can better delineate these lesions, their internal tissue characteristics, and identify adhesion/invasion into adjacent structures. This pictorial essay provides a brief synopsis of the key MRI sequences and their utility in further characterizing mediastinal and paracardiac lesions. PMID:29619281

  19. In vitro color evaluation of esthetic coatings for metallic dental implants and implant prosthetic appliances.

    PubMed

    Pecnik, Christina M; Roos, Malgorzata; Muff, Daniel; Spolenak, Ralph; Sailer, Irena

    2015-05-01

    The aim of this study was to characterize the optical properties of newly developed esthetic coatings for metallic implants and components for an improved peri-implant soft tissue appearance. Pig maxillae (n = 6) were used for the in vitro color evaluation of coated and uncoated samples. Three different coating systems (Ti-ZrO(2), Ti-Al-ZrO(2), and Ti-Ag-ZrO(2)) were deposited on titanium substrates, which exhibited different roughness (polished, machined, and sand-blasted) and interference colors (pink, yellow, and white). Spectrophotometric measurements were made of samples below three different mucosa thicknesses (1 mm, 2 mm, and 3 mm) and titanium served as negative control. Color difference ΔE was calculated using ΔL, Δa, and Δb values for each sample (in total 30 samples). ΔE values were significantly above the threshold value of 3.70 for sand-blasted Ti and Ti-ZrO(2) samples when tested below 1 mm thick soft tissue, hence resulted in a dark appearance of the soft tissues. In contrast, Ti-Al-ZrO(2) and Ti-Ag-ZrO(2) samples showed significant ΔL values below 1 mm, which indicates a brightening of the covering tissue. In general, ΔE values decreased with increasing thickness of the tissue. At 3 mm thick tissue, ΔE values were significantly below 3.70 for Ti-Al-ZrO(2) and Ti-Ag-ZrO(2) samples. The preferable substrate surface should be machined due increased color brightness, good soft tissue integration and improved adhesion between coating and substrates. Improvement of the optical appearance of the metal was achieved with the coating systems Ti-Al-ZrO(2) and Ti-Ag-ZrO(2). Darkening effects could not be observed for these systems, and partially light brightening of the tissue was observed. Advantageous colors were suggested to be pink and yellow. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. In vitro adhesion of Acanthamoeba castellanii to soft contact lenses depends on water content and disinfection procedure.

    PubMed

    Reverey, Julia F; Fromme, Roland; Leippe, Matthias; Selhuber-Unkel, Christine

    2014-08-01

    To compare the potential of different soft contact lenses to be contaminated with Acanthamoeba castellanii as a function of material parameters and cleaning procedures. Different unworn soft hydrogel and silicone hydrogel contact lenses were incubated with human pathogenic A. castellanii. The adhesion of the acanthamoebae was investigated on the contact lenses and put into relation to their material parameters. The efficacy of a recommended contact lens cleaning procedure in reducing A. castellanii adhesion was investigated. We found that material parameters such as elastic modulus, silicone content, ionic properties and swelling do not influence the adhesion of acanthamoebae to soft contact lenses. A material parameter that influenced adhesion significantly was the water content of the lens. With increasing water content, the adhesion of acanthamoebae increased. By following the cleaning instructions of the manufacturer the contamination of the lenses with A. castellanii could be reduced to a minimum, as shown both on contact lenses and in control experiments. With this study we show that for the tested lenses, the adhesion of A. castellanii to contact lenses is independent of the silicone content of the lens, but depends nonlinearly on the water content of the lens. Furthermore, we demonstrate that applying proper lens cleaning procedures minimizes the risk of acanthamoebae adhesion to contact lenses. Copyright © 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  1. Mechanical and biological evaluations of beta-tricalcium phosphate/silicone rubber composite as a novel soft-tissue implant.

    PubMed

    Zhang, Yi-ming; Wang, Shao-liang; Lei, Ze-yuan; Fan, Dong-li

    2009-09-01

    Although silicone rubber (SR) implants are most commonly used and effective for soft-tissue augmentation, they still have been implicated in many adverse reactions. To overcome this problem, a novel composite beta-tricalcium phosphate/silicone rubber (beta-TCP/SR) was prepared by adding beta-TCP into a SR matrix. This study was to evaluate its application potential by investigating the mechanical properties and biocompatibility of beta-TCP/SR. Mechanical properties, including Shore A hardness and tensile strength, were evaluated with 3-mm-thick samples and a universal testing machine. Cytocompatibility tests were conducted in vitro using 0.2-mm-thick beta-TCP/SR samples by seeding fibroblasts onto different samples. Soft-tissue response to beta-TCP/SR and pull-out measurements were investigated 4 weeks and 24 weeks after implantation. The main mechanical properties were all significantly changed after mixing beta-TCP into the SR matrix, except for tearing strength. The cytocompatibility test showed enhanced adhesion and proliferation of fibroblasts onto beta-TCP/SR. Fibrous tissue ingrowth after resorption of beta-TCP was observed by in vivo histologic analysis. The peri-implant capsules in the beta-TCP/SR group were thinner than in the SR group 24 weeks after implantation. In a 24-week test, the maximum force required to pull out the beta-TCP/SR sheet was about six times greater than that needed for SR. Although some mechanical properties were significantly changed, the results of the cytocompatibility test and in vivo animal study still suggest that beta-TCP/SR may be more suitable as a soft-tissue implant than SR and has the potential to be used in plastic surgery.

  2. Elastomeric and soft conducting microwires for implantable neural interfaces

    PubMed Central

    Kolarcik, Christi L.; Luebben, Silvia D.; Sapp, Shawn A.; Hanner, Jenna; Snyder, Noah; Kozai, Takashi D.Y.; Chang, Emily; Nabity, James A.; Nabity, Shawn T.; Lagenaur, Carl F.; Cui, X. Tracy

    2015-01-01

    Current designs for microelectrodes used for interfacing with the nervous system elicit a characteristic inflammatory response that leads to scar tissue encapsulation, electrical insulation of the electrode from the tissue and ultimately failure. Traditionally, relatively stiff materials like tungsten and silicon are employed which have mechanical properties several orders of magnitude different from neural tissue. This mechanical mismatch is thought to be a major cause of chronic inflammation and degeneration around the device. In an effort to minimize the disparity between neural interface devices and the brain, novel soft electrodes consisting of elastomers and intrinsically conducting polymers were fabricated. The physical, mechanical and electrochemical properties of these materials were extensively characterized to identify the formulations with the optimal combination of parameters including Young’s modulus, elongation at break, ultimate tensile strength, conductivity, impedance and surface charge injection. Our final electrode has a Young’s modulus of 974 kPa which is five orders of magnitude lower than tungsten and significantly lower than other polymer-based neural electrode materials. In vitro cell culture experiments demonstrated the favorable interaction between these soft materials and neurons, astrocytes and microglia, with higher neuronal attachment and a two-fold reduction in inflammatory microglia attachment on soft devices compared to stiff controls. Surface immobilization of neuronal adhesion proteins on these microwires further improved the cellular response. Finally, in vivo electrophysiology demonstrated the functionality of the elastomeric electrodes in recording single unit activity in the rodent visual cortex. The results presented provide initial evidence in support of the use of soft materials in neural interface applications. PMID:25993261

  3. Surface Tension Mediated Under-Water Adhesion of Rigid Spheres on Soft, Charged Surfaces

    NASA Astrophysics Data System (ADS)

    Sinha, Shayandev; Das, Siddhartha

    2015-11-01

    Understanding the phenomenon of surface-tension-mediated under-water adhesion is necessary for studying a plethora of physiological and technical phenomena, such as the uptake of bacteria or nanoparticle by cells, attachment of virus on bacterial surfaces, biofouling on large ocean vessels and marine devices, etc. This adhesion phenomenon becomes highly non-trivial in case the soft surface where the adhesion occurs is also charged. Here we propose a theory for analyzing such an under-water adhesion of a rigid sphere on a soft, charged surface, represented by a grafted polyelectrolyte layer (PEL). We develop a model based on the minimization of free energy that, in addition to considering the elastic and the surface-tension-mediated adhesion energies, also accounts for the PEL electric double layer (EDL) induced electrostatic energies. We show that in the presence of surface charges, adhesion gets enhanced. This can be explained by the fact that the increase in the elastic energy is better balanced by the lowering of the EDL energy associated with the adhesion process. The entire behaviour is further dictated by the surface tension components that govern the adhesion energy.

  4. Engineering cellular fibers for musculoskeletal soft tissues using directed self-assembly.

    PubMed

    Schiele, Nathan R; Koppes, Ryan A; Chrisey, Douglas B; Corr, David T

    2013-05-01

    Engineering strategies guided by developmental biology may enhance and accelerate in vitro tissue formation for tissue engineering and regenerative medicine applications. In this study, we looked toward embryonic tendon development as a model system to guide our soft tissue engineering approach. To direct cellular self-assembly, we utilized laser micromachined, differentially adherent growth channels lined with fibronectin. The micromachined growth channels directed human dermal fibroblast cells to form single cellular fibers, without the need for a provisional three-dimensional extracellular matrix or scaffold to establish a fiber structure. Therefore, the resulting tissue structure and mechanical characteristics were determined solely by the cells. Due to the self-assembly nature of this approach, the growing fibers exhibit some key aspects of embryonic tendon development, such as high cellularity, the rapid formation (within 24 h) of a highly organized and aligned cellular structure, and the expression of cadherin-11 (indicating direct cell-to-cell adhesions). To provide a dynamic mechanical environment, we have also developed and characterized a method to apply precise cyclic tensile strain to the cellular fibers as they develop. After an initial period of cellular fiber formation (24 h postseeding), cyclic strain was applied for 48 h, in 8-h intervals, with tensile strain increasing from 0.7% to 1.0%, and at a frequency of 0.5 Hz. Dynamic loading dramatically increased cellular fiber mechanical properties with a nearly twofold increase in both the linear region stiffness and maximum load at failure, thereby demonstrating a mechanism for enhancing cellular fiber formation and mechanical properties. Tissue engineering strategies, designed to capture key aspects of embryonic development, may provide unique insight into accelerated maturation of engineered replacement tissue, and offer significant advances for regenerative medicine applications in tendon, ligament, and other fibrous soft tissues.

  5. Effects of titania nanotubes with or without bovine serum albumin loaded on human gingival fibroblasts

    PubMed Central

    Liu, Xiangning; Zhou, Xiaosong; Li, Shaobing; Lai, Renfa; Zhou, Zhiying; Zhang, Ye; Zhou, Lei

    2014-01-01

    Modifying the surface of the transmucosal area is a key research area because this process positively affects the three functions of implants: attachment to soft tissue, inhibiting bacterial biofilm adhesion, and the preservation of the crestal bone. To exploit the potential of titania nanotube arrays (TNTs) with or without using bovine serum albumin (BSA) to modify the surface of a dental implant in contact with the transmucosal area, BSA was loaded into TNTs that were fabricated by anodizing Ti sheets; the physical characteristics of these arrays, including their morphology, chemical composition, surface roughness, contact angle, and surface free energy (SFE), were assessed. The effect of Ti surfaces with TNTs or TNTs-BSA on human gingival fibroblasts (HGFs) was determined by analyzing cell morphology, early adhesion, proliferation, type I collagen (COL-1) gene expression, and the extracellular secretion of COL-1. The results indicate that early HGF adhesion and spreading behavior is positively correlated with surface characteristics, including hydrophilicity, SFE, and surface roughness. Additionally, TNT surfaces not only promoted early HGF adhesion, but also promoted COL-1 secretion. BSA-loaded TNT surfaces promoted early HGF adhesion, while suppressing late proliferation and COL-1 secretion. Therefore, TNT-modified smooth surfaces are expected to be applicable for uses involving the transmucosal area. Further study is required to determine whether BSA-loaded TNT surfaces actually affect closed loop formation of connective tissue because BSA coating actions in vivo are very rapid. PMID:24623977

  6. Nonwoven-Based Gelatin/Polycaprolactone Membrane Proves Suitability in a Preclinical Assessment for Treatment of Soft Tissue Defects

    PubMed Central

    Schulz, Simon; Angarano, Marco; Fabritius, Martin; Mülhaupt, Rolf; Dard, Michel; Obrecht, Marcel; Tomakidi, Pascal

    2014-01-01

    Standard preclinical assessments in vitro often have limitations regarding their transferability to human beings, mainly evoked by their nonhuman and tissue-different/nontissue-specific source. Here, we aimed at employing tissue-authentic simple and complex interactive fibroblast-epithelial cell systems and their in vivo-relevant biomarkers for preclinical in vitro assessment of nonwoven-based gelatin/polycaprolactone membranes (NBMs) for treatment of soft tissue defects. NBMs were composed of electrospun gelatin and polycaprolactone nanofiber nonwovens. Scanning electron microscopy in conjunction with actin/focal contact integrin fluorescence revealed successful adhesion and proper morphogenesis of keratinocytes and fibroblasts, along with cells' derived extracellular matrix deposits. The “feel-good factor” of cells under study on the NBM was substantiated by forming a confluent connective tissue entity, which was concomitant with a stratified epithelial equivalent. Immunohistochemistry proved tissue authenticity over time by abundance of the biomarker vimentin in the connective tissue entity, and chronological increase of keratins KRT1/10 and involucrin expression in epithelial equivalents. Suitability of the novel NBM as wound dressing was evidenced by an almost completion of epithelial wound closure in a pilot mini-pig study, after a surgical intervention-caused gingival dehiscence. In summary, preclinical assessment by tissue-authentic cell systems and the animal pilot study revealed the NBM as an encouraging therapeutic medical device for prospective clinical applications. PMID:24494668

  7. Biologically and mechanically driven design of an RGD-mimetic macroporous foam for adipose tissue engineering applications.

    PubMed

    Rossi, Eleonora; Gerges, Irini; Tocchio, Alessandro; Tamplenizza, Margherita; Aprile, Paola; Recordati, Camilla; Martello, Federico; Martin, Ivan; Milani, Paolo; Lenardi, Cristina

    2016-10-01

    Despite clinical treatments for adipose tissue defects, in particular breast tissue reconstruction, have certain grades of efficacy, many drawbacks are still affecting the long-term survival of new formed fat tissue. To overcome this problem, in the last decades, several scaffolding materials have been investigated in the field of adipose tissue engineering. However, a strategy able to recapitulate a suitable environment for adipose tissue reconstruction and maintenance is still missing. To address this need, we adopted a biologically and mechanically driven design to fabricate an RGD-mimetic poly(amidoamine) oligomer macroporous foam (OPAAF) for adipose tissue reconstruction. The scaffold was designed to fulfil three fundamental criteria: capability to induce cell adhesion and proliferation, support of in vivo vascularization and match of native tissue mechanical properties. Poly(amidoamine) oligomers were formed into soft scaffolds with hierarchical porosity through a combined free radical polymerization and foaming reaction. OPAAF is characterized by a high water uptake capacity, progressive degradation kinetics and ideal mechanical properties for adipose tissue reconstruction. OPAAF's ability to support cell adhesion, proliferation and adipogenesis was assessed in vitro using epithelial, fibroblast and endothelial cells (MDCK, 3T3L1 and HUVEC respectively). In addition, in vivo subcutaneous implantation in murine model highlighted OPAAF potential to support both adipogenesis and vessels infiltration. Overall, the reported results support the use of OPAAF as a scaffold for engineered adipose tissue construct. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Injectable alginate-O-carboxymethyl chitosan/nano fibrin composite hydrogels for adipose tissue engineering.

    PubMed

    Jaikumar, Dhanya; Sajesh, K M; Soumya, S; Nimal, T R; Chennazhi, K P; Nair, Shantikumar V; Jayakumar, R

    2015-03-01

    Injectable, biodegradable scaffolds are required for soft tissue reconstruction owing to its minimally invasive approach. Such a scaffold can mimic the native extracellular matrix (ECM), provide uniform distribution of cells and overcome limitations like donor site morbidity, volume loss, etc. So, here we report two classes of biocompatible and biodegradable hydrogel blend systems namely, Alginate/O-carboxymethyl chitosan (O-CMC) and Alginate/poly (vinyl alcohol) (PVA) with the inclusion of fibrin nanoparticles in each. The hydrogels were prepared by ionic cross-linking method. The developed hydrogels were compared in terms of its swelling ratio, degradation profile, compressive strength and elastic moduli. From these preliminary findings, it was concluded that Alginate/O-CMC formed a better blend for tissue engineering applications. The potential of the formed hydrogel as an injectable scaffold was revealed by the survival of adipose derived stem cells (ADSCs) on the scaffold by its adhesion, proliferation and differentiation into adipocytes. Cell differentiation studies of fibrin incorporated hydrogel scaffolds showed better differentiation was confirmed by Oil Red O staining technique. These injectable gels have potential in soft tissue regeneration. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Electrospun Nanofiber Scaffolds and Their Hydrogel Composites for the Engineering and Regeneration of Soft Tissues.

    PubMed

    Manoukian, Ohan S; Matta, Rita; Letendre, Justin; Collins, Paige; Mazzocca, Augustus D; Kumbar, Sangamesh G

    2017-01-01

    Electrospinning has emerged as a simple, elegant, and scalable technique that can be used to fabricate polymeric nanofibers. Pure polymers as well as blends and composites of both natural and synthetic ones have been successfully electrospun into nanofiber matrices for many biomedical applications. Tissue-engineered medical implants, such as polymeric nanofiber scaffolds, are potential alternatives to autografts and allografts, which are short in supply and carry risks of disease transmission. These scaffolds have been used to engineer various soft tissues, including connective tissues, such as skin, ligament, and tendon, as well as nonconnective ones, such as vascular, muscle, and neural tissue. Electrospun nanofiber matrices show morphological similarities to the natural extracellular matrix (ECM), characterized by ultrafine continuous fibers, high surface-to-volume ratios, high porosities, and variable pore-size distributions. The physiochemical properties of nanofiber matrices can be controlled by manipulating electrospinning parameters so that they meet the requirements of a specific application.Nanostructured implants show improved biological performance over bulk materials in aspects of cellular infiltration and in vivo integration, taking advantage of unique quantum, physical, and atomic properties. Furthermore, the topographies of such scaffolds has been shown to dictate cellular attachment, migration, proliferation, and differentiation, which are critical in engineering complex functional tissues with improved biocompatibility and functional performance. This chapter discusses the use of the electrospinning technique in the fabrication of polymer nanofiber scaffolds utilized for the regeneration of soft tissues. Selected scaffolds will be seeded with human mesenchymal stem cells (hMSCs), imaged using scanning electron and confocal microscopy, and then evaluated for their mechanical properties as well as their abilities to promote cell adhesion, proliferation , migration, and differentiation.

  10. A PEG-Based Hydrogel for Effective Wound Care Management

    PubMed Central

    Chen, Sen-Lu; Fu, Ru-Huei; Liao, Shih-Fei; Liu, Shih-Ping; Lin, Shinn-Zong; Wang, Yu-Chi

    2018-01-01

    It is extremely challenging to achieve strong adhesion in soft tissues while minimizing toxicity, tissue damage, and other side effects caused by wound sealing materials. In this study, flexible synthetic hydrogel sealants were prepared based on polyethylene glycol (PEG) materials. PEG is a synthetic material that is nontoxic and inert and, thus, suitable for use in medical products. We evaluated the in vitro biocompatibility tests of the dressings to assess cytotoxicity and irritation, sensitization, pyrogen toxicity, and systemic toxicity following the International Organization for Standardization 10993 standards and the in vivo effects of the hydrogel samples using Coloskin liquid bandages as control samples for potential in wound closure. PMID:29637814

  11. Soft tissue adhesion of polished versus glazed lithium disilicate ceramic for dental applications.

    PubMed

    Brunot-Gohin, C; Duval, J-L; Azogui, E-E; Jannetta, R; Pezron, I; Laurent-Maquin, D; Gangloff, S C; Egles, C

    2013-09-01

    Ceramics are widely used materials for prosthesis, especially in dental fields. Despite multiple biomedical applications, little is known about ceramic surface modifications and the resulting cell behavior at its contact. The aim of this study is to evaluate the biological response of polished versus glazed surface treatments on lithium disilicate dental ceramic. We studied a lithium disilicate ceramic (IPS e.max(®) Press, Ivoclar Vivadent) with 3 different surface treatments: raw surface treatment, hand polished surface treatment, and glazed surface treatment (control samples are Thermanox(®), Nunc). In order to evaluate the possible modulation of cell response at the surface of ceramic, we compared polished versus glazed ceramics using an organotypic culture model of chicken epithelium. Our results show that the surface roughness is not modified as demonstrated by equivalent Ra measurements. On the contrary, the contact angle θ in water is very different between polished (84°) and glazed (33°) samples. The culture of epithelial tissues allowed a very precise assessment of histocompatibility of these interfaces and showed that polished samples increased cell adhesion and proliferation as compared to glazed samples. Lithium disilicate polished ceramic provided better adhesion and proliferation than lithium disilicate glazed ceramic. Taken together, our results demonstrate for the first time, how it is possible to use simple surface modifications to finely modulate the adhesion of tissues. Our results will help dental surgeons to choose the most appropriate surface treatment for a specific clinical application, in particular for the ceramic implant collar. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  12. Bi-layered collagen nano-structured membrane prototype (collagen matrix 10826(®)) for oral soft tissue regeneration: an "in vitro" study.

    PubMed

    Nocini, Pier Francesco; Zanotti, Guglielmo; Castellani, Roberto; Grasso, Silvia; Cristofaro, Maria Giulia; De Santis, Daniele

    2013-06-01

    To evaluate fundamental cell functions, such as adhesion, IL-6 production and proliferation of human gingival keratinocytes cultured on a newly engineered collagen matrix (CM-10826) and to assess the degree of specific biocompatibility of this new device. Primary cultures of human keratinocytes were derived "in vitro" from biopsies of independent donors. Their true epithelial origin was ensured by the expression of cytokeratin 14. Adhesion, proliferation and production of IL-6 cytokine was then measured in the presence or absence of CM-10826 activity or of its relevant components. Functional tests revealed that keratinocytes adhered to CM-10826 and up-regulated their basal IL-6 production. The type of keratinocytes used expressed cytokeratin 14. Proliferation experiments demonstrated that the best cellular response was observed in the presence of Collagen I, the main component of CM-10826. No undesired effects were observed as for keratinocyte viability, morphology or differentiation. Our results demonstrate that CM-10826 has a favourable biological effect on the "in vitro" response of gingival keratinocytes in terms of IL-6 production, cell growth and adhesion. These findings may encourage a possible use of this collagen membrane as a tissue which, alone, may substitute for autologous gingival grafts thereby overcoming the limitations of autologous tissue. © 2012 John Wiley & Sons A/S.

  13. Plasma Electrolytic Oxidation of Titanium Implant Surfaces: Microgroove-Structures Improve Cellular Adhesion and Viability.

    PubMed

    Hartjen, Philip; Hoffmann, Alexia; Henningsen, Anders; Barbeck, Mike; Kopp, Alexander; Kluwe, Lan; Precht, Clarissa; Quatela, Olivia; Gaudin, Robert; Heiland, Max; Friedrich, Reinhard E; Knipfer, Christian; Grubeanu, Daniel; Smeets, Ralf; Jung, Ole

    2018-01-01

    Plasma electrolytic oxidation (PEO) is an established electrochemical treatment technique that can be used for surface modifications of metal implants. In this study we to treated titanium implants with PEO, to examine the resulting microstructure and to characterize adhesion and viability of cells on the treated surfaces. Our aim was to identify an optimal surface-modification for titanium implants in order to improve soft-tissue integration. Three surface-variants were generated on titanium alloy Ti6Al4V by PEO-treatment. The elemental composition and the microstructures of the surfaces were characterized using energy dispersive X-ray spectroscopy, scanning electron microscopy and profilometry. In vitro cytocompatibility of the surfaces was assessed by seeding L929 fibroblasts onto them and measuring the adhesion, viability and cytotoxicity of cells by means of live/dead staining, XTT assay and LDH assay. Electron microscopy and profilometry revealed that the PEO-surface variants differed largely in microstructure/topography, porosity and roughness from the untreated control material as well as from one another. Roughness was generally increased after PEO-treatment. In vitro, PEO-treatment led to improved cellular adhesion and viability of cells accompanied by decreased cytotoxicity. PEO-treatment provides a promising strategy to improve the integration of titanium implants with surrounding tissues. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  14. The effect of aspect ratio on adhesion and stiffness for soft elastic fibres

    PubMed Central

    Aksak, Burak; Hui, Chung-Yuen; Sitti, Metin

    2011-01-01

    The effect of aspect ratio on the pull-off stress and stiffness of soft elastic fibres is studied using elasticity and numerical analysis. The adhesive interface between a soft fibre and a smooth rigid surface is modelled using the Dugdale–Barenblatt model. Numerical simulations show that, while pull-off stress increases with decreasing aspect ratio, fibres get stiffer. Also, for sufficiently low aspect ratio fibres, failure occurs via the growth of internal cracks and pull-off stress approaches the intrinsic adhesive strength. Experiments carried out with various aspect ratio polyurethane elastomer fibres are consistent with the numerical simulations. PMID:21227962

  15. Tissue adhesion to bioactive glass-coated silicone tubing in a rat model of peritoneal dialysis catheters and catheter tunnels.

    PubMed

    Ross, Edward A; Batich, Christopher D; Clapp, William L; Sallustio, Judith E; Lee, Nadeen C

    2003-02-01

    Silicone peritoneal dialysis catheters do not develop tissue ingrowth, lack a mechanical barrier to periluminal bacterial migration and need cuffs for anchorage. We hypothesized that a bioactive glass coating composed of silicon, calcium, sodium and phosphorous oxides would cause a beneficial tissue reaction causing catheter adhesion, and tested this in a rat model. A hexane solvent-based method of coating silicone tubes with Bioglass powder was used, which maintained flexibility, and then the ultrastructure was confirmed with scanning electron microscopy (EM). Segments 2.5 cm were implanted subcutaneously in 8 Sprague-Dawley rats, with uncoated tubes as a contralateral control, and histology was done at 2, 4 and 6 weeks, including special stains and EM. The uncoated segments grossly had no adherence to surrounding tissue, and were physically separate from a thin fibrous capsule of approximately 50 micro width. Trichrome stains demonstrated the capsule was rich in collagen. There was minimal adjacent tissue reaction. In contrast, the coated tubes were palpably fixed to the soft tissues, and sections demonstrated an adjacent prominent layer of macrophages and multinucleated giant cells. Small numbers of lymphocytes were noted. This cellular reaction increased over the 6-week implant duration, and was also associated with neovascularization of the tissue adjacent to the segments (33 vessels in coated vs. 20 in controls per x 200 field, P < 0.0001). Many refractile silicone particles and prominent multinucleated giant cells were present, with small numbers of lymphocytes and macrophages. Stains showed scattered discontinuous calcific deposits. These findings are consistent with reports that the Bioglass(R) silicon oxide leads to the formation of a layer of hydroxyapatite, which binds to collagen and induces a tissue cellular reaction. In summary, bioactive glass coatings can improve the tissue retention of silicone tubing by promoting adhesion by collagen and cell proliferation, and are promising for future studies of peritoneal dialysis catheters.

  16. Wetting and phase separation in soft adhesion

    PubMed Central

    Jensen, Katharine E.; Sarfati, Raphael; Style, Robert W.; Boltyanskiy, Rostislav; Chakrabarti, Aditi; Chaudhury, Manoj K.; Dufresne, Eric R.

    2015-01-01

    In the classic theory of solid adhesion, surface energy drives deformation to increase contact area whereas bulk elasticity opposes it. Recently, solid surface stress has been shown also to play an important role in opposing deformation of soft materials. This suggests that the contact line in soft adhesion should mimic that of a liquid droplet, with a contact angle determined by surface tensions. Consistent with this hypothesis, we observe a contact angle of a soft silicone substrate on rigid silica spheres that depends on the surface functionalization but not the sphere size. However, to satisfy this wetting condition without a divergent elastic stress, the gel phase separates from its solvent near the contact line. This creates a four-phase contact zone with two additional contact lines hidden below the surface of the substrate. Whereas the geometries of these contact lines are independent of the size of the sphere, the volume of the phase-separated region is not, but rather depends on the indentation volume. These results indicate that theories of adhesion of soft gels need to account for both the compressibility of the gel network and a nonzero surface stress between the gel and its solvent. PMID:26553989

  17. Determination of adhesion between thermoplastic and liquid silicone rubbers in hard-soft-combinations via mechanical peeling test

    NASA Astrophysics Data System (ADS)

    Kühr, C.; Spörrer, A.; Altstädt, V.

    2014-05-01

    The production of hard-soft-combinations via multi injection molding gained more and more importance in the last years. This is attributed to different factors. One principle reason is that the use of two-component injection molding technique has many advantages such as cancelling subsequent and complex steps and shortening the process chain. Furthermore this technique allows the combination of the properties of the single components like the high stiffness of the hard component and the elastic properties of the soft component. Because of the incompatibility of some polymers the adhesion on the interface has to be determined. Thereby adhesion is not only influenced by the applied polymers, but also by the injection molding parameters and the characteristics of the mold. Besides already known combinations of thermoplastics with thermoplastic elastomers (TPE), there consists the possibility to apply liquid silicone rubber (LSR) as soft component. A thermoplastic/LSR combination gains in importance due to the specific advantages of LSR to TPE. The faintly adhesion between LSR and thermoplastics is currently one of the key challenges when dealing with those combinations. So it is coercively necessary to improve adhesion between the two components by adding an adhesion promoter. To determine the promoters influence, it is necessary to develop a suitable testing method to investigate e.g. the peel resistance. The current German standard "VDI Richtlinie 2019', which is actually only employed for thermoplastic/TPE combinations, can serve as a model to determine the adhesion of thermoplastic/LSR combinations.

  18. Use of wound dressings with soft silicone adhesive technology.

    PubMed

    Morris, Clare; Emsley, Paulene; Marland, Elizabeth; Meuleneire, Frans; White, Richard

    2009-04-01

    To evaluate how pain, during and in-between dressing changes, is affected by the introduction of Mepilex Border Lite, a wound dressing manufactured by Mölnlycke Health Care using Safetac soft silicone adhesive technology, to the treatment of different types of paediatric wounds/skin injuries. Wounds/skin injuries that met the criteria for inclusion in the study were dressed with Mepilex Border Lite. Patients were followed for six weeks or until their wounds/skin injuries had healed, whichever occurred earlier. At each dressing change, pain severity before and during dressing removal was rated by the patient and the investigator on a scale from zero (no pain at all) to ten (worst pain ever). Other variables measured included: signs of trauma to wound/skin injury and surrounding skin, the proportion of viable/non-viable tissue, the quantity and appearance of exudate, odour, and clinical signs of infection. At the final dressing change, patients and investigators completed questionnaires to rate the dressing performance. Mean pain severity scores were significantly lower (p < or = 0.003) at the first dressing change than at baseline. Over 99.5 per cent of the Mepilex Border Lite dressing changes were reported to be atraumatic and more than half of the wounds healed within the study period. Conformability, ease of use, ease of removal, patient comfort, and overall experience with the dressing were rated as 'good' to 'very good' at the vast majority of final visit evaluations. This study provides further evidence of the ability of dressings with Safetac soft silicone adhesive technology to minimise trauma and pain and demonstrates the ability of Mepilex Border Lite to overcome the clinical challenges associated with the use of dressings on the wounds/skin injuries of paediatric patients.

  19. Preparation and High-temperature Anti-adhesion Behavior of a Slippery Surface on Stainless Steel.

    PubMed

    Zhang, Pengfei; Huawei, Chen; Liu, Guang; Zhang, Liwen; Zhang, Deyuan

    2018-03-29

    Anti-adhesion surfaces with high-temperature resistance have a wide application potential in electrosurgical instruments, engines, and pipelines. A typical anti-wetting superhydrophobic surface easily fails when exposed to a high-temperature liquid. Recently, Nepenthes-inspired slippery surfaces demonstrated a new way to solve the adhesion problem. A lubricant layer on the slippery surface can act as a barrier between the repelled materials and the surface structure. However, the slippery surfaces in previous studies rarely showed high-temperature resistance. Here, we describe a protocol for the preparation of slippery surfaces with high-temperature resistance. A photolithography-assisted method was used to fabricate pillar structures on stainless steel. By functionalizing the surface with saline, a slippery surface was prepared by adding silicone oil. The prepared slippery surface maintained the anti-wetting property for water, even when the surface was heated to 300 °C. Also, the slippery surface exhibited great anti-adhesion effects on soft tissues at high temperatures. This type of slippery surface on stainless steel has applications in medical devices, mechanical equipment, etc.

  20. Development of Photocrosslinkable Urethane-Doped Polyester Elastomers for Soft Tissue Engineering

    PubMed Central

    Zhang, Yi; Tran, Richard T.; Gyawali, Dipendra; Yang, Jian

    2012-01-01

    Finding an ideal biomaterial with the proper mechanical properties and biocompatibility has been of intense focus in the field of soft tissue engineering. This paper reports on the synthesis and characterization of a novel crosslinked urethane-doped polyester elastomer (CUPOMC), which was synthesized by reacting a previously developed photocrosslinkable poly (octamethylene maleate citrate) (POMC) prepolymers (pre-POMC) with 1,6-hexamethylene diisocyanate (HDI) followed by thermo- or photo-crosslinking polymerization. The mechanical properties of the CUPOMCs can be tuned by controlling the molar ratios of pre-POMC monomers, and the ratio between the prepolymer and HDI. CUPOMCs can be crosslinked into a 3D network through polycondensation or free radical polymerization reactions. The tensile strength and elongation at break of CUPOMC synthesized under the known conditions range from 0.73±0.12MPa to 10.91±0.64MPa and from 72.91±9.09% to 300.41±21.99% respectively. Preliminary biocompatibility tests demonstrated that CUPOMCs support cell adhesion and proliferation. Unlike the pre-polymers of other crosslinked elastomers, CUPOMC pre-polymers possess great processability demonstrated by scaffold fabrication via a thermally induced phase separation method. The dual crosslinking methods for CUPOMC pre-polymers should enhance the versatile processability of the CUPOMC used in various conditions. Development of CUPOMC should expand the choices of available biodegradable elastomers for various biomedical applications such as soft tissue engineering. PMID:23565318

  1. Sonographic differentiation of digital tendon rupture from adhesive scarring after primary surgical repair.

    PubMed

    Budovec, Joseph J; Sudakoff, Gary S; Dzwierzynski, William W; Matloub, Hani S; Sanger, James R

    2006-04-01

    After the surgical repair of finger tendons finger range of motion may be limited by tendon rupture or adhesive scarring. Differentiating tendon rupture from adhesive scarring may be difficult clinically. Digital tendon sonography allows the evaluation of tendon integrity in a dynamic setting. Our objective was to determine if sonography could differentiate tendon rupture from adhesive scarring in patients who have had primary tendon repair. A retrospective review was performed of the radiographic, clinical, and surgical records of patients referred for finger sonography over a 2-year period. Twenty-eight digits in 21 patients were evaluated for finger tendon disruption after primary surgical repair. The diagnosis of complete tendon rupture was made when 1 or more of the following was identified: a gap separating the proximal and distal tendon margins, visualization of only the proximal tendon margin, or visualization of only the distal tendon margin. Adhesive scarring was diagnosed if the tendon appeared intact with abnormal peritendinous soft tissue abutting or partially encasing the tendon, with synovial sheath thickening, or with restricted tendon motion during dynamic evaluation. Sonography correctly identified tendon rupture or adhesive scarring in 27 of 28 digits with 1 false-positive case (sensitivity, 100%; specificity, 93%; positive-predictive value, 93%; negative-predictive value, 100%; accuracy, 96%). Sonography is an accurate modality for differentiating tendon rupture from adhesive scarring in patients with prior surgical tendon repair. Diagnostic, Level I.

  2. Properties of pressure sensitive adhesives found in paper recycling operations

    Treesearch

    Ryan F. Verhulst; Steven J. Severtson; Jihui Guo; Carl J. Houtman

    2006-01-01

    Hot melt and water-based adhesives are very different materials with similar physical properties. Their ability to act as adhesives is due to physical bonds and mechanical interlocks which form as adhesive flows into topographical features on the substrate surface. Hot-melt adhesives are based on soft, rubbery polymers while water-based adhesives are usually acrylic...

  3. Surface Entrapment of Fibronectin on Electrospun PLGA Scaffolds for Periodontal Tissue Engineering

    PubMed Central

    Gritsch, Kerstin; Salles, Vincent; Attik, Ghania N.; Grosgogeat, Brigitte

    2014-01-01

    Abstract Nowadays, the challenge in the tissue engineering field consists in the development of biomaterials designed to regenerate ad integrum damaged tissues. Despite the current use of bioresorbable polyesters such as poly(l-lactide) (PLA), poly(d,l-lactide-co-glycolide) (PLGA), and poly-ɛ-caprolactone in soft tissue regeneration researches, their hydrophobic properties negatively influence the cell adhesion. Here, to overcome it, we have developed a fibronectin (FN)-functionalized electrospun PLGA scaffold for periodontal ligament regeneration. Functionalization of electrospun PLGA scaffolds was performed by alkaline hydrolysis (0.1 or 0.01 M NaOH). Then, hydrolyzed scaffolds were coated by simple deposition of an FN layer (10 μg/mL). FN coating was evidenced by X-ray photoelectron analysis. A decrease of contact angle and greater cell adhesion to hydrolyzed, FN-coated PLGA scaffolds were noticed. Suitable degradation behavior without pH variations was observed for all samples up to 28 days. All treated materials presented strong shrinkage, fiber orientation loss, and collapsed fibers. However, functionalization process using 0.01 M NaOH concentration resulted in unchanged scaffold porosity, preserved chemical composition, and similar mechanical properties compared with untreated scaffolds. The proposed simplified method to functionalize electrospun PLGA fibers is an efficient route to make polyester scaffolds more biocompatible and shows potential for tissue engineering. PMID:24940563

  4. [Novel artificial lamina for prevention of epidural adhesions after posterior cervical laminectomy].

    PubMed

    Lü, Chaoliang; Song, Yueming; Liu, Hao; Liu, Limin; Gong, Quan; Li, Tao; Zeng, Jiancheng; Kong, Qingquan; Pei, Fuxing; Tu, Chongqi; Duan, Hong

    2013-07-01

    To evaluate the application of artificial lamina of multi-amino-acid copolymer (MAACP)/nano-hydroxyapatite (n-HA) in prevention of epidural adhesion and compression of scar tissue after posterior cervical laminectomy. Fifteen 2-year-old male goats [weighing, (30 +/- 2) kg] were randomly divided into experimental group (n=9) and control group (n=6). In the experimental group, C4 laminectomy was performed, followed by MAACP/n-HA artificial lamina implantations; in the control group, only C4 laminectomy was performed. At 4, 12, and 24 weeks after operation, 2, 2, and 5 goats in the experimental group and 2, 2, and 2 goats in the control group were selected for observation of wound infection, artificial laminar fragmentation and displacement, and its shape; Rydell's degree of adhesion criteria was used to evaluate the adhesion degree between 2 groups. X-ray and CT images were observed; at 24 weeks after operation, CT scan was used to measure the spinal canal area and the sagittal diameter of C3, C4, and C5 vertebrea, 2 normal goats served as normal group; and MRI was used to assess adhesion and compression of scar tissue on the dura and the nerve root. Then goats were sacrificed and histological observation was carried out. After operation, the wound healed well; no toxicity or elimination reaction was observed. According to Rydell's degree of adhesion criteria, adhesion in the experimental group was significantly slighter than that in the control group (Z= -2.52, P=0.00). X-ray and CT scan showed that no dislocation of artificial lamina occurred, new cervical bone formed in the defect, and bony spinal canal was rebuilt in the experimental group. Defects of C4 vertebral plate and spinous process were observed in the control group. At 24 weeks, the spinal canal area and sagittal diameter of C4 in the experimental group and normal group were significantly larger than those in the control group (P < 0.05), but no significant difference was found between experimental group and normal group (P > 0.05). MRI showed cerebrospinal fluid signal was unobstructed and no soft tissue projected into the spinal canal in the experimental group; scar tissue projected into the spinal canal and the dura were compressed by scar tissue in the control group. HE staining and Masson trichrome staining showed that artificial lamina had no obvious degradation with high integrity, some new bone formed at interface between the artificial material and bone in the experimental group; fibrous tissue grew into defect in the control group. The MAACP/n-HA artificial lamina could maintaine good biomechanical properties for a long time in vivo and could effectively prevent the epidural scar from growing in the lamina defect area.

  5. Hydroxyapatite nanorods: soft-template synthesis, characterization and preliminary in vitro tests.

    PubMed

    Nguyen, Nga Kim; Leoni, Matteo; Maniglio, Devid; Migliaresi, Claudio

    2013-07-01

    Synthetic hydroxyapatite nanorods are excellent candidates for bone tissue engineering applications. In this study, hydroxyapatite nanorods resembling bone minerals were produced by using soft-template method with cetyltrimethylammonium bromide. Composite hydroxyapatite/poly(D, L)lactic acid films were prepared to evaluate the prepared hydroxyapatite nanorods in terms of cell affinity. Preliminary in vitro experiments showed that aspect ratio and film surface roughness play a vital role in controlling adhesion and proliferation of human osteoblast cell line MG 63. The hydroxyapatite nanorods with aspect ratios in the range of 5.94-7 were found to possess distinctive properties, with the corresponding hydroxyapatite/poly(D, L)lactic acid films promoting cellular confluence and a fast formation of collagen fibers as early as after 7 days of culture.

  6. Mounting ground sections of teeth: Cyanoacrylate adhesive versus Canada balsam.

    PubMed

    Vangala, Manogna Rl; Rudraraju, Amrutha; Subramanyam, R V

    2016-01-01

    Hard tissues can be studied by either decalcification or by preparing ground sections. Various mounting media have been tried and used for ground sections of teeth. However, there are very few studies on the use of cyanoacrylate adhesive as a mounting medium. The aim of our study was to evaluate the efficacy of cyanoacrylate adhesive (Fevikwik™) as a mounting medium for ground sections of teeth and to compare these ground sections with those mounted with Canada balsam. Ground sections were prepared from twenty extracted teeth. Each section was divided into two halves and mounted on one slide, one with cyanoacrylate adhesive (Fevikwik™) and the other with Canada balsam. Scoring for various features in the ground sections was done by two independent observers. Statistical analysis using Student's t-test (unpaired) of average scores was performed for each feature observed. No statistically significant difference was found between the two for most of the features. However, cyanoacrylate was found to be better than Canada balsam for observing striae of Retzius (P < 0.0205), enamel lamellae (P < 0.036), dentinal tubules (P < 0.0057), interglobular dentin (P < 0.0001), sclerotic dentin - transmitted light (P < 0.00001), sclerotic dentin - polarized light (P < 0.0002) and Sharpey's fibers (P < 0.0004). This initial study shows that cyanoacrylate is better than Canada balsam for observing certain features of ground sections of teeth. However, it remains to be seen whether it will be useful for studying undecalcified sections of carious teeth and for soft tissue sections.

  7. Collecting and Storing Tissue, Blood, and Bone Marrow Samples From Patients With Rhabdomyosarcoma or Other Soft Tissue Sarcoma

    ClinicalTrials.gov

    2017-12-11

    Adult Rhabdomyosarcoma; Childhood Desmoplastic Small Round Cell Tumor; Chordoma; Desmoid Tumor; Metastatic Childhood Soft Tissue Sarcoma; Nonmetastatic Childhood Soft Tissue Sarcoma; Previously Treated Childhood Rhabdomyosarcoma; Previously Untreated Childhood Rhabdomyosarcoma; Recurrent Adult Soft Tissue Sarcoma; Recurrent Childhood Rhabdomyosarcoma; Recurrent Childhood Soft Tissue Sarcoma; Stage I Adult Soft Tissue Sarcoma; Stage II Adult Soft Tissue Sarcoma; Stage III Adult Soft Tissue Sarcoma; Stage IV Adult Soft Tissue Sarcoma

  8. Tunable smart digital structure (SDS) to modularly assemble soft actuators with layered adhesive bonding

    NASA Astrophysics Data System (ADS)

    Jin, Hu; Dong, Erbao; Xu, Min; Xia, Qirong; Liu, Shuai; Li, Weihua; Yang, Jie

    2018-01-01

    Many shape memory alloy (SMA)-based soft actuators have specific composite structures and manufacture processes, and are therefore unique. However, these exclusive characteristics limit their capabilities and applications, so in this article a soft and smart digital structure (SDS) is proposed that acts like a modular unit to assemble soft actuators by a layered adhesive bonding process. The SDS is a fully soft structure that encapsulates a digital skeleton consisting of four groups of parallel and independently actuated SMA wires capable of outputting a four-channel tunable force. The layered adhesive bonding process modularly bonds several SDSs with an elastic backbone to fabricate a layered soft actuator where the elastic backbone is used to recover the SDSs in a cooling process using the SMA wires. Two kinds of SDS-based soft actuators were modularly assembled, an actuator, SDS-I, with a two-dimensional reciprocal motion, and an actuator, SDS-II, capable of bi-directional reciprocal motion. The thermodynamics and phase transformation modeling of the SDS-based actuator were analyzed. Several extensional soft actuators were also assembled by bonding the SDS with an anomalous elastic backbone or modularly assembling the SDS-Is and SDS-IIs. These modularly assembled soft actuators delivered more output channels and a complicated motion, e.g., an actinomorphic soft actuator with four SDS-Is jumps in a series of hierarchical heights and directional movement by tuning the input channels of the SDSs. This result showed that the SDS can modularly assemble multifarious soft actuators with diverse capabilities, steerability and tunable outputs.

  9. Evaluation of friction enhancement through soft polymer micro-patterns in active capsule endoscopy

    NASA Astrophysics Data System (ADS)

    Buselli, Elisa; Pensabene, Virginia; Castrataro, Piero; Valdastri, Pietro; Menciassi, Arianna; Dario, Paolo

    2010-10-01

    Capsule endoscopy is an emerging field in medical technology. Despite very promising innovations, some critical issues are yet to be addressed, such as the management and possible exploitation of the friction in the gastrointestinal environment in order to control capsule locomotion more actively. This paper presents the fabrication and testing of bio-inspired polymeric micro-patterns, which are arrays of cylindrical pillars fabricated via soft lithography. The aim of the work is to develop structures that enhance the grip between an artificial device and the intestinal tissue, without injuring the mucosa. In fact, the patterns are intended to be mounted on microfabricated legs of a capsule robot that is able to move actively in the gastrointestinal tract, thus improving the robot's traction ability. The effect of micro-patterned surfaces on the leg-slipping behaviour on colon walls was investigated by considering both different pillar dimensions and the influence of tissue morphology. Several in vitro tests on biological samples demonstrated that micro-patterns of pillars made from a soft polymer with an aspect ratio close to 1 enhanced friction by 41.7% with regard to flat surfaces. This work presents preliminary modelling of the friction and adhesion forces in the gastrointestinal environment and some design guidelines for endoscopic devices.

  10. Enhanced Cellular Adhesion on Titanium by Silk Functionalized with titanium binding and RGD peptides

    PubMed Central

    Vidal, Guillaume; Blanchi, Thomas; Mieszawska, Aneta J.; Calabrese, Rossella; Rossi, Claire; Vigneron, Pascale; Duval, Jean-Luc; Kaplan, David L.; Egles, Christophe

    2012-01-01

    Soft tissue adhesion on titanium represents a challenge for implantable materials. In order to improve adhesion at the cell/material interface we used a new approach based on the molecular recognition of titanium by specific peptides. Silk fibroin protein was chemically grafted with titanium binding peptide (TiBP) to increase adsorption of these chimeric proteins to the metal surface. Quartz Crystal Microbalance was used to quantify the specific adsorption of TiBP-functionalized silk and an increase in protein deposition by more than 35% was demonstrated due to the presence of the binding peptide. A silk protein grafted with TiBP and fibronectin-derived RGD peptide was then prepared. The adherence of fibroblasts on the titanium surface modified with the multifunctional silk coating demonstrated an increase in the number of adhering cells by 60%. The improved adhesion was demonstrated by Scanning Electron Microscopy and immunocytochemical staining of focal contact points. Chick embryo organotypic culture also revealed strong adhesion of endothelial cells expanding on the multifunctional silk-peptide coating. These results demonstrated that silk functionalized with TiBP and RGD represents a promising approach to modify cell-biomaterial interfaces, opening new perspectives for implantable medical devices, especially when reendothelialization is required. PMID:22975628

  11. Isolated Limb Perfusion of Melphalan With or Without Tumor Necrosis Factor in Treating Patients With Soft Tissue Sarcoma of the Arm or Leg

    ClinicalTrials.gov

    2012-03-14

    Stage IVB Adult Soft Tissue Sarcoma; Stage IIB Adult Soft Tissue Sarcoma; Stage IIC Adult Soft Tissue Sarcoma; Recurrent Adult Soft Tissue Sarcoma; Stage IVA Adult Soft Tissue Sarcoma; Stage III Adult Soft Tissue Sarcoma

  12. Safety and effectiveness of a polyvinyl alcohol barrier in reducing risks of vascular tissue damage during anterior spinal revision surgery.

    PubMed

    Jeffords, Paul; Li, Jinsheng; Panchal, Deepal; Denoziere, Guilhem; Fetterolf, Donald

    2012-05-01

    This study was conducted as a controlled, prospective investigation to show the safety and efficacy of a polyvinyl alcohol (PVA) device in a sheep model. To evaluate the ability of a permanent PVA hydrogel barrier to reduce the risk of potential vessel damage during anterior vertebral revision surgery, to provide a nonadhesive barrier at the surgical site, and to create a surgical revision plane of dissection. The development of scar tissue and adhesions presents a significant postoperative problem in spine surgery, where adhesion involvement of overlying structures can cause pain, neurovascular complications, and present a difficult surgical environment during revisions. The devices were implanted onto the ventral surface of exposed lumbar intervertebral discs using an anterolateral approach. One disc separated from the study site was also exposed to serve as a control. Three sheep each were then evaluated with an explant procedure at 30 and 90 days. Extensive sampling was undertaken to evaluate gross anatomic, micropathologic, and biochemical environments and properties of the device. The structural properties and appearance of the device remained intact at both 30 and 90 days. The material remained flexible, hydrophilic, and soft, without visible resorption or decomposition. The material was well tolerated by the animal, with minimal histologic signs of inflammation or rejection. Tissue planes were easily able to be localized by the surgeon attempting to locate the prior surgical site at the time of resection. The PVA vessel shield effectively protected the structures overlying the sheep spine during revision, providing a clear dissection plane for resection at repeat surgery. The overlying structures separated from the previous surgical site with no adhesion, and allowed safe separation of adjacent tissues without the use of sharp dissection.

  13. The effect of autologous fibrin tissue adhesive on postoperative cerebrospinal fluid leak in spinal cord surgery: a randomized controlled trial.

    PubMed

    Nakamura, Hiroshi; Matsuyama, Yukihiro; Yoshihara, Hisatake; Sakai, Yoshihito; Katayama, Yoshito; Nakashima, Shojiro; Takamatsu, Jyunki; Ishiguro, Naoki

    2005-07-01

    A prospective randomized study evaluating the efficacy of autologous fibrin tissue adhesive for decreasing postoperative cerebrospinal fluid (CSF) leak in spinal cord surgery. To compare postoperative CSF leak in 3 groups (i.e., autologous fibrin tissue adhesive used, commercial fibrin glue used, and no fibrin tissue adhesive used) of patients undergoing spinal surgery who needed dural incision. Spinal cord operations, particularly when dural incision is inevitable, sometimes involve postoperative CSF leak. Because CSF leak is a serious complication, countermeasure is necessary to prevent it after dural suture. Commercial fibrin tissue adhesive was formerly used. Because the possibility of prion infection was widely noticed, commercial fibrin tissue adhesive containing animal components has been used less often. In 13 of 39 cases in which dural incision would be made, 400 mL whole blood was drawn, and autologous fibrin tissue adhesive was made of plasma. Cases were divided into 3 groups: (1) dural closure alone, (2) use of autologous fibrin tissue adhesive after dural closure, and (3) use of commercial fibrin tissue adhesive after dural closure. The primary outcome measure was determined as postoperative (3 days) volume of drainage fluid, and results were analyzed using the analysis of variance. The secondary outcome measure was general blood test, coagulation assay, and plasma fibrinogen, and these were analyzed also using the analysis of variance. There was a significant difference in the primary outcome between the autologous and control groups. No complications such as infection or continuous CSF leak were observed in any case. The mean volume of drainage fluid was 586.2 mL in the group with autologous fibrin tissue adhesive and 1026.1 mL in the group without fibrin tissue adhesive. The volume of drainage fluid was significantly lower in the former group than that in the latter group. There was no statistical difference between the volumes of the group with autologous adhesive and with commercial adhesive (639.2 mL). We used autologous fibrin tissue adhesive as a new sealant after dural closure instead of commercial fibrin tissue adhesive. No definitive CSF leak was observed, and the volume of drainage fluid was significantly lower in the group with autologous fibrin tissue adhesive than that in the group without fibrin tissue adhesive. The use of autologous fibrin tissue adhesive was superior to that of commercial fibrin tissue adhesive in cost.

  14. Soft Polydimethylsiloxane Elastomers from Architecture-driven Entanglement Free Design

    PubMed Central

    Cai, Li-Heng; Kodger, Thomas E.; Guerra, Rodrigo E.; Pegoraro, Adrian F.; Rubinstein, Michael; Weitz, David A.

    2015-01-01

    We fabricate soft, solvent-free polydimethylsiloxane (PDMS) elastomers by crosslinking bottlebrush polymers rather than linear polymers. We design the chemistry to allow commercially available linear PDMS precursors to deterministically form bottlebrush polymers, which are simultaneously crosslinked, enabling a one-step synthesis. The bottlebrush architecture prevents the formation of entanglements, resulting in elastomers with precisely controllable elastic moduli from ~1 to ~100 kPa, below the intrinsic lower limit of traditional elastomers. Moreover, the solvent-free nature of the soft PDMS elastomers enables a negligible contact adhesion compared to commercially available silicone products of similar stiffness. The exceptional combination of softness and negligible adhesiveness may greatly broaden the applications of PDMS elastomers in both industry and research. PMID:26259975

  15. Technical manual for manufacturing autologous fibrin tissue adhesive.

    PubMed

    Park, J J; Cintron, J R; Siedentop, K H; Orsay, C P; Pearl, R K; Nelson, R L; Abcarian, H

    1999-10-01

    The aim of this article is to provide a concise and simple technical manual for manufacturing autologous fibrin tissue adhesive derived from the precipitation of fibrinogen using a combination of ethanol and freezing for surgery. All materials and equipment needed to manufacture ethanol-based autologous fibrin tissue adhesive are listed. In addition, step-by-step instructions are provided to allow for easy and rapid fibrin adhesive production. Ethanol-based autologous fibrin tissue adhesive can be manufactured in under 60 minutes. Furthermore, at our institution the startup cost for manufacturing ethanol-based autologous fibrin tissue adhesive was under $2,500.00. Ethanol-based autologous fibrin tissue adhesive is a safe, reliable, and easily manufactured autologous fibrin tissue adhesive that can be made by a trained technician in any blood bank, pharmacy, or surgical laboratory.

  16. Exogenous administration of Substance P enhances wound healing in a novel skin-injury model.

    PubMed

    Delgado, Angel V; McManus, Albert T; Chambers, James P

    2005-04-01

    Soft tissue injury accounts for approximately 44% of all wounds in both the military and civilian populations. Following injury to soft tissue, Substance P (SP) and other neuropeptides are released by cutaneous neurons and modulate the function of immunocompetent and inflammatory cells, as well as epithelial and endothelial cells. The interaction between these components of the nervous system and multiple target cells affecting cutaneous repair is of increasing interest. In this report, we describe the effects of SP on wound repair in a novel, laser-induced, skin-wound model. Gross and histologic examination of laser-induced injury revealed that exogenously administered SP affects wound healing via neurite outgrowth, in addition to adhesion molecule and neurokinin-1 receptor involvement in vivo. All SP effects were decreased by pretreatment with Spantide II, an SP antagonist. The elucidation of SP-mediating mechanisms is crucial to firmly establishing the involvement and interaction of the peripheral nervous system and the immune system in cutaneous repair. Findings presented here suggest that SP participates in the complex network of mediators involved in cutaneous inflammation and wound healing.

  17. Adhesion and interfacial fracture toughness between hard and soft materials

    NASA Astrophysics Data System (ADS)

    Rahbar, Nima; Wolf, Kurt; Orana, Argjenta; Fennimore, Roy; Zong, Zong; Meng, Juan; Papandreou, George; Maryanoff, Cynthia; Soboyejo, Wole

    2008-11-01

    This paper presents the results of a combined experimental and theoretical study of adhesion between hard and soft layers that are relevant to medical devices such as drug-eluting stents and semiconductor applications. Brazil disk specimens were used to measure the interfacial fracture energies between model parylene C and 316L stainless steel over a wide range of mode mixities. The trends in the overall fracture energies are predicted using a combination of adhesion theories and fracture mechanics concepts. The measured interfacial fracture energies are shown to be in good agreement with the predictions.

  18. Molecular Approach to Conjugated Polymers with Biomimetic Properties.

    PubMed

    Baek, Paul; Voorhaar, Lenny; Barker, David; Travas-Sejdic, Jadranka

    2018-06-13

    The field of bioelectronics involves the fascinating interplay between biology and human-made electronics. Applications such as tissue engineering, biosensing, drug delivery, and wearable electronics require biomimetic materials that can translate the physiological and chemical processes of biological systems, such as organs, tissues. and cells, into electrical signals and vice versa. However, the difference in the physical nature of soft biological elements and rigid electronic materials calls for new conductive or electroactive materials with added biomimetic properties that can bridge the gap. Soft electronics that utilize organic materials, such as conjugated polymers, can bring many important features to bioelectronics. Among the many advantages of conjugated polymers, the ability to modulate the biocompatibility, solubility, functionality, and mechanical properties through side chain engineering can alleviate the issues of mechanical mismatch and provide better interface between the electronics and biological elements. Additionally, conjugated polymers, being both ionically and electrically conductive through reversible doping processes provide means for direct sensing and stimulation of biological processes in cells, tissues, and organs. In this Account, we focus on our recent progress in molecular engineering of conjugated polymers with tunable biomimetic properties, such as biocompatibility, responsiveness, stretchability, self-healing, and adhesion. Our approach is general and versatile, which is based on functionalization of conjugated polymers with long side chains, commonly polymeric or biomolecules. Applications for such materials are wide-ranging, where we have demonstrated conductive, stimuli-responsive antifouling, and cell adhesive biointerfaces that can respond to external stimuli such as temperature, salt concentration, and redox reactions, the processes that in turn modify and reversibly switch the surface properties. Furthermore, utilizing the advantageous chemical, physical, mechanical and functional properties of the grafts, we progressed into grafting of the long side chains onto conjugated polymers in solution, with the vision of synthesizing solution-processable conjugated graft copolymers with biomimetic functionalities. Examples of the developed materials to date include rubbery and adhesive photoluminescent plastics, biomolecule-functionalized electrospun biosensors, thermally and dually responsive photoluminescent conjugated polymers, and tunable self-healing, adhesive, and stretchable strain sensors, advanced functional biocidal polymers, and filtration membranes. As outlined in these examples, the applications of these biomimetic, conjugated polymers are still in the development stage toward truly printable, organic bioelectronic devices. However, in this Account, we advocate that molecular engineering of conjugated polymers is an attractive approach to a versatile class of organic electronics with both ionic and electrical conductivity as well as mechanical properties required for next-generation bioelectronics.

  19. Natural Tissue Microenvironmental Conditions Modulate Adhesive Material Performance

    PubMed Central

    Oliva, Nuria; Shitreet, Sagi; Abraham, Eytan; Stanley, Butch; Edelman, Elazer R.; Artzi, Natalie

    2015-01-01

    We designed and optimized tissue-responsive adhesive materials by matching material and tissue properties. A two-component material based on dextran aldehyde and dendrimer amine provides a cohesive gel through aldehyde–amine cross-linking and an adhesive interface created by a dextran aldehyde-selective reaction with tissue amines. By altering aldehyde–amine chemistry, we examined how variations in tissue surfaces (serosal amine density in the duodenum, jejunum, and ileum) affect interactions with adhesive materials of varied compositions (aldehyde content). Interestingly, the same adhesive formulation reacts differentially with the three regions of the small intestine as a result of variation in the tissue amine density along the intestinal tract, affecting the tissue–material interfacial morphology, adhesion strength, and adhesive mechanical properties. Whereas tissues provide chemical anchors for interaction with materials, we were able to tune the adhesion strength for each section of the small intestine tissue by altering the adhesive formulation using a two-component material with flexible variables aimed at controlling the aldehyde/amine ratio. This tissue-specific approach should be applied to the broad spectrum of biomaterials, taking into account specific microenvironmental conditions in material design. PMID:23046479

  20. 21 CFR 878.4010 - Tissue adhesive.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ..., is a device used for adhesion of internal tissues and vessels. (2) Classification. Class III... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Tissue adhesive. 878.4010 Section 878.4010 Food... DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4010 Tissue adhesive. (a) Tissue...

  1. 21 CFR 878.4010 - Tissue adhesive.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ..., is a device used for adhesion of internal tissues and vessels. (2) Classification. Class III... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Tissue adhesive. 878.4010 Section 878.4010 Food... DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4010 Tissue adhesive. (a) Tissue...

  2. Mechano-sensing and mechano-reaction of soft connective tissue cells

    NASA Astrophysics Data System (ADS)

    Lambert, Ch. A.; Nusgens, B. V.; Lapière, Ch. M.

    One main function of the connective tissues is to provide cells with a mechanically resistant attachment support required for survival, division and differentiation. All cells contain membrane-anchored attachment proteins able to recognize specific chemical motifs in the extracellular macromolecules forming the supporting scaffold, made of various types of collagen, adhesive glycoproteins, elastin, proteoglycans, etc... These cell-matrix interactions are mainly mediated by re ceptors of the integrins family, heterodimeric molecules made of an extracellular domain connected through a transmembrane sequence to an intracytoplasmic tail. Upon recognition of the extracellular ligand, the clustering and activation of the integrins result in the recruitment of a complex of proteins and formation of the focal adhesion plaque, containing both cytoskeletal and catalytic signaling molecules. Activation results in polymerization of actin and formation of stress fibers. These structures establish a physical link between the extracellular matrix components and the cytoskeleton through the integrins providing a continuous path acting as a mechanotransducer. This connection is used by the cells to perform their mechanical functions as adhesion, migration and traction. In vitro experimental models using fibroblasts in a collagen gel demonstrate that cells are in mechanical equilibrium with their support which regulates their replicative and biosynthetic phenotype. The present review discusses the molecular structures operating in the transmission of the mechanical messages from the support to the connective tissue cells, and their effect on the cellular machinery. We present arguments for investigating these mechanisms in understanding the perception of reduced gravity and the resulting reaction leading to microgravity induced pathologies.

  3. Photocrosslinkable chitosan as a biological adhesive.

    PubMed

    Ono, K; Saito, Y; Yura, H; Ishikawa, K; Kurita, A; Akaike, T; Ishihara, M

    2000-02-01

    A photocrosslinkable chitosan to which both azide and lactose moieties were introduced (Az-CH-LA) was prepared as a biological adhesive for soft tissues and its effectiveness was compared with that of fibrin glue. Introduction of the lactose moieties resulted in a much more water-soluble chitosan at neutral pH. Application of ultraviolet light (UV) irradiation to photocrosslinkable Az-CH-LA produced an insoluble hydrogel within 60 s. This hydrogel firmly adhered two pieces of sliced ham with each other, depending upon the Az-CH-LA concentration. The binding strength of the chitosan hydrogel prepared from 30-50 mg/mL of Az-CH-LA was similar to that of fibrin glue. Compared to the fibrin glue, the chitosan hydrogel more effectively sealed air leakage from pinholes on isolated small intestine and aorta and from incisions on isolated trachea. Neither Az-CH-LA nor its hydrogel showed any cytotoxicity in cell culture tests of human skin fibroblasts, coronary endothelial cells, and smooth muscle cells. Furthermore, all mice studied survived for at least 1 month after implantation of 200 microL of photocrosslinked chitosan gel and intraperitoneal administration of up to 1 mL of 30 mg/mL of Az-CH-LA solution. These results suggest that the photocrosslinkable chitosan developed here has the potential of serving as a new tissue adhesive in medical use. Copyright 2000 John Wiley & Sons, Inc.

  4. Mounting ground sections of teeth: Cyanoacrylate adhesive versus Canada balsam

    PubMed Central

    Vangala, Manogna RL; Rudraraju, Amrutha; Subramanyam, RV

    2016-01-01

    Introduction: Hard tissues can be studied by either decalcification or by preparing ground sections. Various mounting media have been tried and used for ground sections of teeth. However, there are very few studies on the use of cyanoacrylate adhesive as a mounting medium. Aims: The aim of our study was to evaluate the efficacy of cyanoacrylate adhesive (Fevikwik™) as a mounting medium for ground sections of teeth and to compare these ground sections with those mounted with Canada balsam. Materials and Methods: Ground sections were prepared from twenty extracted teeth. Each section was divided into two halves and mounted on one slide, one with cyanoacrylate adhesive (Fevikwik™) and the other with Canada balsam. Scoring for various features in the ground sections was done by two independent observers. Statistical Analysis Used: Statistical analysis using Student's t-test (unpaired) of average scores was performed for each feature observed. Results: No statistically significant difference was found between the two for most of the features. However, cyanoacrylate was found to be better than Canada balsam for observing striae of Retzius (P < 0.0205), enamel lamellae (P < 0.036), dentinal tubules (P < 0.0057), interglobular dentin (P < 0.0001), sclerotic dentin – transmitted light (P < 0.00001), sclerotic dentin – polarized light (P < 0.0002) and Sharpey's fibers (P < 0.0004). Conclusions: This initial study shows that cyanoacrylate is better than Canada balsam for observing certain features of ground sections of teeth. However, it remains to be seen whether it will be useful for studying undecalcified sections of carious teeth and for soft tissue sections. PMID:27194857

  5. The efficacy of instrument assisted soft tissue mobilization: a systematic review.

    PubMed

    Cheatham, Scott W; Lee, Matt; Cain, Matt; Baker, Russell

    2016-09-01

    Instrument assisted soft tissue mobilization (IASTM) is a popular treatment for myofascial restriction. IASTM uses specially designed instruments to provide a mobilizing effect to scar tissue and myofascial adhesions. Several IASTM tools and techniques are available such as the Graston® technique. Currently, there are no systematic reviews that have specifically appraised the effects of IASTM as a treatment or to enhance joint range of motion (ROM). The purpose of this study was to systematically appraise the current evidence assessing the effects of IASTM as an intervention to treat a musculoskeletal pathology or to enhance joint ROM. A search of the literature was conducted during the month of December 2015 which included the following databases: PubMed, PEDro, Science Direct, and the EBSCOhost collection. A direct search of known journals was also conducted to identify potential publications. The search terms included individual or a combination of the following: instrument; assisted; augmented; soft-tissue; mobilization; Graston®; and technique. A total of 7 randomized controlled trials were appraised. Five of the studies measured an IASTM intervention versus a control or alternate intervention group for a musculoskeletal pathology. The results of the studies were insignificant (p>.05) with both groups displaying equal outcomes. Two studies measured an IASTM intervention versus a control or alternate intervention group on the effects of joint ROM. The IASTM intervention produced significant (P<.05) short term gains up to 24 hours. The literature measuring the effects of IASTM is still emerging. The current research has indicated insignificant results which challenges the efficacy of IASTM as a treatment for common musculoskeletal pathology, which may be due to the methodological variability among studies. There appears to be some evidence supporting its ability to increase short term joint ROM.

  6. Talimogene Laherparepvec and Radiation Therapy in Treating Patients With Newly Diagnosed Soft Tissue Sarcoma That Can Be Removed by Surgery

    ClinicalTrials.gov

    2018-05-23

    FNCLCC Sarcoma Grade 2; FNCLCC Sarcoma Grade 3; Leiomyosarcoma; Liposarcoma; Stage I Soft Tissue Sarcoma AJCC v7; Stage IA Soft Tissue Sarcoma AJCC v7; Stage IB Soft Tissue Sarcoma AJCC v7; Stage II Soft Tissue Sarcoma AJCC v7; Stage IIA Soft Tissue Sarcoma AJCC v7; Stage IIB Soft Tissue Sarcoma AJCC v7; Undifferentiated Pleomorphic Sarcoma

  7. Composite Pillars with a Tunable Interface for Adhesion to Rough Substrates

    PubMed Central

    2016-01-01

    The benefits of synthetic fibrillar dry adhesives for temporary and reversible attachment to hard objects with smooth surfaces have been successfully demonstrated in previous studies. However, surface roughness induces a dramatic reduction in pull-off stresses and necessarily requires revised design concepts. Toward this aim, we introduce cylindrical two-phase single pillars, which are composed of a mechanically stiff stalk and a soft tip layer. Adhesion to smooth and rough substrates is shown to exceed that of conventional pillar structures. The adhesion characteristics can be tuned by varying the thickness of the soft tip layer, the ratio of the Young’s moduli and the curvature of the interface between the two phases. For rough substrates, adhesion values similar to those obtained on smooth substrates were achieved. Our concept of composite pillars overcomes current practical limitations caused by surface roughness and opens up fields of application where roughness is omnipresent. PMID:27997118

  8. Sorafenib in Treating Patients With Soft Tissue Sarcomas (Extremity Sarcoma Closed to Entry as of 5/30/07)

    ClinicalTrials.gov

    2014-04-01

    Metastatic Ewing Sarcoma/Peripheral Primitive Neuroectodermal Tumor; Metastatic Osteosarcoma; Recurrent Adult Soft Tissue Sarcoma; Recurrent Ewing Sarcoma/Peripheral Primitive Neuroectodermal Tumor; Recurrent Osteosarcoma; Stage I Adult Soft Tissue Sarcoma; Stage II Adult Soft Tissue Sarcoma; Stage III Adult Soft Tissue Sarcoma; Stage IV Adult Soft Tissue Sarcoma

  9. Endoscopic-assisted Repair of Neglected Rupture or Rerupture After Primary Repair of Extensor Hallucis Longus Tendon.

    PubMed

    Lui, Tun Hing; Chang, Joseph Jeremy; Maffulli, Nicola

    2016-03-01

    Rerupture of the extensor hallucis longus tendon after primary repair and neglected rupture of the tendon poses surgical challenges to orthopedic surgeons. Open exploration and repair of the tendon ends usually requires large incision and extensive dissection. This may induce scarring and adhesion around the repaired tendon. Endoscopic-assisted repair has the advantage of minimally invasive surgery including less soft tissue trauma and scar formation and better cosmetic result. The use of Krackow locking suture and preservation of the extensor retinacula allow early mobilization of the great toe.

  10. Tough Adhesives for Diverse Wet Surfaces

    PubMed Central

    Li, J.; Celiz, A. D.; Yang, J.; Yang, Q.; Wamala, I.; Whyte, W.; Seo, B. R.; Vasilyev, N. V.; Vlassak, J. J.; Suo, Z.; Mooney, D. J.

    2018-01-01

    Adhesion to wet and dynamic surfaces, including biological tissues, is important in many fields, but has proven extremely challenging. Existing adhesives are either cytotoxic, adhere weakly to tissues, or cannot be utilized in wet environments. We report a bio-inspired design for adhesives consisting of two layers: an adhesive surface and a dissipative matrix. The former adheres to the substrate by electrostatic interactions, covalent bonds, and physical interpenetration. The latter amplifies energy dissipation through hysteresis. The two layers synergistically lead to higher adhesion energy on wet surfaces than existing adhesives. Adhesion occurs within minutes, independent of blood exposure, and compatible with in vivo dynamic movements. This family of adhesives may be useful in many areas of application, including tissue adhesives, wound dressings and tissue repair. PMID:28751604

  11. Selective and uncoupled role of substrate elasticity in the regulation of replication and transcription in epithelial cells.

    PubMed

    Kocgozlu, Leyla; Lavalle, Philippe; Koenig, Géraldine; Senger, Bernard; Haikel, Youssef; Schaaf, Pierre; Voegel, Jean-Claude; Tenenbaum, Henri; Vautier, Dominique

    2010-01-01

    Actin cytoskeleton forms a physical connection between the extracellular matrix, adhesion complexes and nuclear architecture. Because tissue stiffness plays key roles in adhesion and cytoskeletal organization, an important open question concerns the influence of substrate elasticity on replication and transcription. To answer this major question, polyelectrolyte multilayer films were used as substrate models with apparent elastic moduli ranging from 0 to 500 kPa. The sequential relationship between Rac1, vinculin adhesion assembly, and replication becomes efficient at above 200 kPa because activation of Rac1 leads to vinculin assembly, actin fiber formation and, subsequently, to initiation of replication. An optimal window of elasticity (200 kPa) is required for activation of focal adhesion kinase through auto-phosphorylation of tyrosine 397. Transcription, including nuclear recruitment of heterogeneous nuclear ribonucleoprotein A1 (hnRNP A1), occurred above 50 kPa. Actin fiber and focal adhesion signaling are not required for transcription. Above 50 kPa, transcription was correlated with alphav-integrin engagement together with histone H3 hyperacetylation and chromatin decondensation, allowing little cell spreading. By contrast, soft substrate (below 50 kPa) promoted morphological changes characteristic of apoptosis, including cell rounding, nucleus condensation, loss of focal adhesions and exposure of phosphatidylserine at the outer cell surface. On the basis of our data, we propose a selective and uncoupled contribution from the substrate elasticity to the regulation of replication and transcription activities for an epithelial cell model.

  12. Observation, Radiation Therapy, Combination Chemotherapy, and/or Surgery in Treating Young Patients With Soft Tissue Sarcoma

    ClinicalTrials.gov

    2017-09-07

    Adult Alveolar Soft-part Sarcoma; Adult Angiosarcoma; Adult Epithelioid Sarcoma; Adult Extraskeletal Chondrosarcoma; Adult Extraskeletal Osteosarcoma; Adult Fibrosarcoma; Adult Leiomyosarcoma; Adult Liposarcoma; Adult Malignant Fibrous Histiocytoma; Adult Malignant Hemangiopericytoma; Adult Malignant Mesenchymoma; Adult Neurofibrosarcoma; Adult Synovial Sarcoma; Childhood Alveolar Soft-part Sarcoma; Childhood Angiosarcoma; Childhood Epithelioid Sarcoma; Childhood Fibrosarcoma; Childhood Leiomyosarcoma; Childhood Liposarcoma; Childhood Malignant Mesenchymoma; Childhood Neurofibrosarcoma; Childhood Synovial Sarcoma; Dermatofibrosarcoma Protuberans; Metastatic Childhood Soft Tissue Sarcoma; Nonmetastatic Childhood Soft Tissue Sarcoma; Stage I Adult Soft Tissue Sarcoma; Stage II Adult Soft Tissue Sarcoma; Stage III Adult Soft Tissue Sarcoma; Stage IV Adult Soft Tissue Sarcoma

  13. Treatment of Skin Depression with Combined Upward Suture Traction and Percutaneous Subcision

    PubMed Central

    Bins-Ely, Jorge; Paulo, Elizabeth Machado; Lee, Kuang Hee

    2015-01-01

    Background: Scar retraction and soft-tissue depression may compromise aesthetics and cause social embarrassment. The purpose of this study was to evaluate the results of treating soft-tissue depressions or retractions at varied anatomy regions with combined upward suture traction and percutaneous subcision. Methods: There were 40 patients (age: mean, 39 years; range, 22–55 years; 39 women and 1 man) (total, 77 soft-tissue lesions) who had treatment with the present technique from 1996 to 2013. Postoperative follow-up was from 6 months to 2 years. The treated anatomic areas were evaluated in 5 groups: (1) face (8 patients; 8 lesions); (2) gluteal (16 patients; 46 lesions); (3) breast (7 patients; 10 lesions); (4) abdomen (7 patients; 7 lesions); and (5) lower limb (2 patients; 6 lesions). The technique included placing a 2-0 nylon monofilament suture deep at the core of the depression, pulling vertically up with the suture, and using a needle or miniblade (placed percutaneously or through a small incision) to release the adhesions. Results: The depressions were released successfully in all patients. Bruises around treated areas persisted for 2–3 weeks. Moderate induration persisted until 3 months. In the gluteal region, 6 patients who had retracted areas with diameter >5 cm developed seroma after treatment; the seromas resolved after needle aspiration or placement of a Penrose drain for 2 weeks (2 patients). Conclusion: The present results confirmed the efficacy of the combined subcision method with upward traction at diverse body sites as previously reported for inverted nipple in the breast. PMID:26579340

  14. A postoperative anti-adhesion barrier based on photoinduced imine-crosslinking hydrogel with tissue-adhesive ability.

    PubMed

    Yang, Yunlong; Liu, Xiaolin; Li, Yan; Wang, Yang; Bao, Chunyan; Chen, Yunfeng; Lin, Qiuning; Zhu, Linyong

    2017-10-15

    Postoperative adhesion is a serious complication that can further lead to morbidity and/or mortality. Polymer anti-adhesion barrier material provides an effective precaution to reduce the probability of postoperative adhesion. Clinical application requires these materials to be easily handled, biocompatible, biodegradable, and most importantly tissue adherent to provide target sites with reliable isolation. However, currently there is nearly no polymer barrier material that can fully satisfy these requirements. In this study, based on the photoinduced imine-crosslinking (PIC) reaction, we had developed a photo-crosslinking hydrogel (CNG hydrogel) that composed of o-nitrobenzyl alcohol (NB) modified carboxymethyl cellulose (CMC-NB) and glycol chitosan (GC) as an anti-adhesion barrier material. Under light irradiation, CMC-NB generated aldehyde groups which subsequently reacted with amino groups distributed on GC or tissue surface to form a hydrogel barrier that covalently attached to tissue surface. Rheological analysis demonstrated that CNG hydrogel (30mg/mL polymer content) could be formed in 30s upon light irradiation. Tissue adhesive tests showed that the tissue adhesive strength of CNG hydrogel (30mg/mL) was about 8.32kPa-24.65kPa which increased with increasing CMC-NB content in CNG hydrogel. Toxicity evaluation by L929 cells demonstrated that CNG hydrogel was cytocompatible. Furthermore, sidewall defect-cecum abrasion model of rat was employed to evaluate the postoperative anti-adhesion efficacy of CNG hydrogel. And a significantly reduction of tissue adhesion (20% samples with low score adhesion) was found in CNG hydrogel treated group, compared with control group (100% samples with high score adhesion). In addition, CNG hydrogel could be degraded in nearly 14days and showed no side effect on wound healing. These findings indicated that CNG hydrogel can effectively expanded the clinical treatments of postoperative tissue adhesion. In this study, a tissue adhesive photo-crosslinking hydrogel (CNG) was developed based on photo-induced imine crosslinking reaction (PIC) for postoperative anti-adhesion. CNG hydrogel showed the features of easy and convenient operation, fast and controllable gelation, suitable gel strength, good biocompatibility, and most importantly strong tissue adhesiveness. Therefore, it shows very high performance to prevent postoperative tissue adhesion. Overall, our study provides a more suitable hydrogel barrier material that can overcome the shortcomings of current barriers for clinical postoperative anti-adhesion. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  15. Cytotoxicity of four categories of dental cements.

    PubMed

    Schmid-Schwap, Martina; Franz, Alexander; König, Franz; Bristela, Margit; Lucas, Trevor; Piehslinger, Eva; Watts, David C; Schedle, Andreas

    2009-03-01

    Assessment of dental material biocompatibility is gaining increasing importance for both patients and dentists. Dental cements may be in contact with oral soft tissues for prolonged periods of time and play an important role in prosthetic rehabilitation. The aim of the present study was to evaluate eight dental cements using a standardized L929-fibroblast cell culture test. For each material, fresh specimens (added to the cultures immediately after preparation) and specimens preincubated for 7 days in cell culture medium were prepared according to the manufacturers' recommendations. After exposure to test specimens, cell numbers were compared to glass controls. The main outcome was a two-sided 95% confidence interval for the mean value of the standardized cell number for each substance investigated. Fresh specimens of all tested cements showed significant cytotoxicity, which diminished after 7 days preincubation. Cytotoxicity of fresh adhesive and self-adhesive resin cements was lower when specimens were dual-cured compared to self-cured. A rank order of cytotoxicity was established based on mean values: Nexus 2 (dual-cured) showed least cytotoxicity, followed by Variolink II (dual-cured), Nexus 2 (self-cured), Harvard, RelyxUnicem (dual-cured), Panavia 21, Fujicem, Durelon, Variolink II (self-cured), RelyxUnicem (self-cured), Maxcem (dual-cured) and Maxcem (self-cured). When bondings were added to Nexus 2 or Variolink II specimens, a slight increase in cytotoxicity was observed. Adhesive resin cements showed less cytotoxicity than self-adhesive and chemically setting cements. Bonding only slightly influenced cytotoxicity of the adhesive resin cements. Dual-cured specimens of adhesive and self-adhesive resin cements showed significantly less toxicity than self-cured specimens.

  16. An electromechanical based deformable model for soft tissue simulation.

    PubMed

    Zhong, Yongmin; Shirinzadeh, Bijan; Smith, Julian; Gu, Chengfan

    2009-11-01

    Soft tissue deformation is of great importance to surgery simulation. Although a significant amount of research efforts have been dedicated to simulating the behaviours of soft tissues, modelling of soft tissue deformation is still a challenging problem. This paper presents a new deformable model for simulation of soft tissue deformation from the electromechanical viewpoint of soft tissues. Soft tissue deformation is formulated as a reaction-diffusion process coupled with a mechanical load. The mechanical load applied to a soft tissue to cause a deformation is incorporated into the reaction-diffusion system, and consequently distributed among mass points of the soft tissue. Reaction-diffusion of mechanical load and non-rigid mechanics of motion are combined to govern the simulation dynamics of soft tissue deformation. An improved reaction-diffusion model is developed to describe the distribution of the mechanical load in soft tissues. A three-layer artificial cellular neural network is constructed to solve the reaction-diffusion model for real-time simulation of soft tissue deformation. A gradient based method is established to derive internal forces from the distribution of the mechanical load. Integration with a haptic device has also been achieved to simulate soft tissue deformation with haptic feedback. The proposed methodology does not only predict the typical behaviours of living tissues, but it also accepts both local and large-range deformations. It also accommodates isotropic, anisotropic and inhomogeneous deformations by simple modification of diffusion coefficients.

  17. Soft Lithography and Minimally Human Invasive Technique for Rapid Screening of Oral Biofilm Formation on New Microfabricated Dental Material Surfaces

    PubMed Central

    Alvarez-Escobar, Marta; Hansford, Derek; Monteiro, Fernando J.

    2018-01-01

    Introduction Microfabrication offers opportunities to study surface concepts focused to reduce bacterial adhesion on implants using human minimally invasive rapid screening (hMIRS). Wide information is available about cell/biomaterial interactions using eukaryotic and prokaryotic cells on surfaces of dental materials with different topographies, but studies using human being are still limited. Objective To evaluate a synergy of microfabrication and hMIRS to study the bacterial adhesion on micropatterned surfaces for dental materials. Materials and Methods Micropatterned and flat surfaces on biomedical PDMS disks were produced by soft lithography. The hMIRS approach was used to evaluate the total oral bacterial adhesion on PDMS surfaces placed in the oral cavity of five volunteers (the study was approved by the University Ethical Committee). After 24 h, the disks were analyzed using MTT assay and light microscopy. Results In the present pilot study, microwell structures were microfabricated on the PDMS surface via soft lithography with a spacing of 5 µm. Overall, bacterial adhesion did not significantly differ between the flat and micropatterned surfaces. However, individual analysis of two subjects showed greater bacterial adhesion on the micropatterned surfaces than on the flat surfaces. Significance Microfabrication and hMIRS might be implemented to study the cell/biomaterial interactions for dental materials. PMID:29593793

  18. Abdominal Adhesions

    MedlinePlus

    ... Clearinghouse What are abdominal adhesions? Abdominal adhesions are bands of fibrous tissue that can form between abdominal ... Esophagus Stomach Large intestine Adhesion Abdominal adhesions are bands of fibrous tissue that can form between abdominal ...

  19. A method to screen and evaluate tissue adhesives for joint repair applications

    PubMed Central

    2012-01-01

    Background Tissue adhesives are useful means for various medical procedures. Since varying requirements cause that a single adhesive cannot meet all needs, bond strength testing remains one of the key applications used to screen for new products and study the influence of experimental variables. This study was conducted to develop an easy to use method to screen and evaluate tissue adhesives for tissue engineering applications. Method Tissue grips were designed to facilitate the reproducible production of substrate tissue and adhesive strength measurements in universal testing machines. Porcine femoral condyles were used to generate osteochondral test tissue cylinders (substrates) of different shapes. Viability of substrates was tested using PI/FDA staining. Self-bonding properties were determined to examine reusability of substrates (n = 3). Serial measurements (n = 5) in different operation modes (OM) were performed to analyze the bonding strength of tissue adhesives in bone (OM-1) and cartilage tissue either in isolation (OM-2) or under specific requirements in joint repair such as filling cartilage defects with clinical applied fibrin/PLGA-cell-transplants (OM-3) or tissues (OM-4). The efficiency of the method was determined on the basis of adhesive properties of fibrin glue for different assembly times (30 s, 60 s). Seven randomly generated collagen formulations were analyzed to examine the potential of method to identify new tissue adhesives. Results Viability analysis of test tissue cylinders revealed vital cells (>80%) in cartilage components even 48 h post preparation. Reuse (n = 10) of test substrate did not significantly change adhesive characteristics. Adhesive strength of fibrin varied in different test settings (OM-1: 7.1 kPa, OM-2: 2.6 kPa, OM-3: 32.7 kPa, OM-4: 30.1 kPa) and was increasing with assembly time on average (2.4-fold). The screening of the different collagen formulations revealed a substance with significant higher adhesive strength on cartilage (14.8 kPa) and bone tissue (11.8 kPa) compared to fibrin and also considerable adhesive properties when filling defects with cartilage tissue (23.2 kPa). Conclusion The method confirmed adhesive properties of fibrin and demonstrated the dependence of adhesive properties and applied settings. Furthermore the method was suitable to screen for potential adhesives and to identify a promising candidate for cartilage and bone applications. The method can offer simple, replicable and efficient evaluation of adhesive properties in ex vivo specimens and may be a useful supplement to existing methods in clinical relevant settings. PMID:22984926

  20. Multifunctional nanoparticles as a tissue adhesive and an injectable marker for image-guided procedures

    NASA Astrophysics Data System (ADS)

    Shin, Kwangsoo; Choi, Jin Woo; Ko, Giho; Baik, Seungmin; Kim, Dokyoon; Park, Ok Kyu; Lee, Kyoungbun; Cho, Hye Rim; Han, Sang Ihn; Lee, Soo Hong; Lee, Dong Jun; Lee, Nohyun; Kim, Hyo-Cheol; Hyeon, Taeghwan

    2017-07-01

    Tissue adhesives have emerged as an alternative to sutures and staples for wound closure and reconnection of injured tissues after surgery or trauma. Owing to their convenience and effectiveness, these adhesives have received growing attention particularly in minimally invasive procedures. For safe and accurate applications, tissue adhesives should be detectable via clinical imaging modalities and be highly biocompatible for intracorporeal procedures. However, few adhesives meet all these requirements. Herein, we show that biocompatible tantalum oxide/silica core/shell nanoparticles (TSNs) exhibit not only high contrast effects for real-time imaging but also strong adhesive properties. Furthermore, the biocompatible TSNs cause much less cellular toxicity and less inflammation than a clinically used, imageable tissue adhesive (that is, a mixture of cyanoacrylate and Lipiodol). Because of their multifunctional imaging and adhesive property, the TSNs are successfully applied as a hemostatic adhesive for minimally invasive procedures and as an immobilized marker for image-guided procedures.

  1. Can tissue adhesives and platelet-rich plasma prevent pharyngocutaneous fistula formation?

    PubMed

    Eryılmaz, Aylin; Demirci, Buket; Gunel, Ceren; Kacar Doger, Firuzan; Yukselen, Ozden; Kurt Omurlu, Imran; Basal, Yesim; Agdas, Fatih; Basak, Sema

    2016-02-01

    One of the frequently encountered disorders of wound healing following laryngectomy is pharyngocutaneous fistula. However, although studies have been performed with the aim of prevention of pharyngocutaneous fistulae, there are very few studies with tissue adhesives and platelet-rich plasma. In this study, our aim was to investigate the histopathologic changes in wound healing caused by various tissue adhesives and platelet-rich plasma, together with their effects on prevention of pharyngocutaneous fistula. 40 male rats were randomly divided into five groups: control, platelet-rich plasma, fibrin tissue adhesive, protein-based albumin glutaraldehyde and synthetic tissue adhesive groups. The pharyngotomy procedure was performed and was sutured. Except the control group, tissue adhesives and platelet-rich plasma were applied. Then, the skin was sutured. On the seventh day, the rats were sacrificed. The skin was opened and pharyngotomy site was assessed in terms of fistulae. The pharyngeal suture line was evaluated histopathologically by using Ehrlich Hunt scale. Inflammatory infiltration was found to be higher in "platelet-rich plasma" group than "fibrin tissue adhesive" and "synthetic tissue adhesive" groups. The fibroblastic activity of "platelet-rich plasma", "fibrin tissue adhesive" and "protein-based albumin glutaraldehyde" groups was higher than the control group. The positive changes created by platelet-rich plasma and fibrin tissue adhesive at the histopathologic level were found together with no detected fistula. Among the study groups, there was no statistical difference for pharyngeal fistula development. This result may be obtained by the small number of animal experiments. These results shed light on the suggestion that platelet-rich plasma and fibrin tissue adhesive can be used in clinical studies to prevent pharyngocutaneous fistula. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  2. Diode laser soft-tissue surgery: advancements aimed at consistent cutting, improved clinical outcomes.

    PubMed

    Romanos, Georgios E

    2013-01-01

    Laser dentistry and soft-tissue surgery, in particular, have become widely adopted in recent years. Significant cost reductions for dental lasers and the increasing popularity of CADCAM, among other factors, have contributed to a substantial increase in the installed base of dental lasers, especially soft-tissue lasers. New development in soft-tissue surgery, based on the modern understanding of laser-tissue interactions and contact soft-tissue surgery mechanisms, will bring a higher quality and consistency level to laser soft-tissue surgery. Recently introduced diode-laser technology enables enhanced control of side effects that result from tissue overheating and may improve soft-tissue surgical outcomes.

  3. Photochemical tissue bonding with chitosan adhesive films

    PubMed Central

    2010-01-01

    Background Photochemical tissue bonding (PTB) is a promising sutureless technique for tissue repair. PTB is often achieved by applying a solution of rose bengal (RB) between two tissue edges, which are irradiated by a green laser to crosslink collagen fibers with minimal heat production. In this study, RB has been incorporated in chitosan films to create a novel tissue adhesive that is laser-activated. Methods Adhesive films, based on chitosan and containing ~0.1 wt% RB were manufactured and bonded to calf intestine by a solid state laser (λ = 532 nm, Fluence~110 J/cm2, spot size~0.5 cm). A single-column tensiometer, interfaced with a personal computer, tested the bonding strength. K-type thermocouples recorded the temperature (T) at the adhesive-tissue interface during laser irradiation. Human fibroblasts were also seeded on the adhesive and cultured for 48 hours to assess cell growth. Results The RB-chitosan adhesive bonded firmly to the intestine with adhesion strength of 15 ± 2 kPa, (n = 31). The adhesion strength dropped to 0.5 ± 0.1 (n = 8) kPa when the laser was not applied to the adhesive. The average temperature of the adhesive increased from 26°C to 32°C during laser exposure. Fibroblasts grew confluent on the adhesive without morphological changes. Conclusion A new biocompatible chitosan adhesive has been developed that bonds photochemically to tissue with minimal temperature increase. PMID:20825632

  4. Upregulation of adhesion complex proteins and fibronectin by human keratinocytes treated with an aqueous extract from the leaves of Chromolaena odorata (Eupolin).

    PubMed

    Phan, T T; Allen, J; Hughes, M A; Cherry, G; Wojnarowska, F

    2000-01-01

    The fresh leaves and extract of the plant Chromolaena odorata are a traditional herbal treatment in developing countries for burns, soft tissue wounds and skin infections. We have previously shown that the extract had an effect on the growth and proliferation of keratinocytes and fibroblasts in culture. This study has demonstrated that Eupolin extract increased expression of several components of the adhesion complex and fibronectin by human keratinocytes. Using indirect immunofluorescence we found increased expression (dose-dependent) of laminin 5, laminin 1, collagen IV, and fibronectin. The expression of the b1 and b4 integrins was upregulated by the extract at low concentrations (0.1 and 1 microg/ml), but the expression was decreased at higher doses of Eupolin (10 microg-150 microg/ml). A number of clinical studies carried out by Vietnamese and international medical investigators have demonstrated the efficacy of this extract on the wound healing process. In this study we have shown that Eupolin stimulated the expression of many proteins of the adhesion complex and fibronectin by human keratinocytes. The adhesion complex proteins are essential to stabilise epithelium and this effect could contribute to the clinical efficacy of Eupolin in healing.

  5. Tissue adhesives for closure of surgical incisions.

    PubMed

    Dumville, Jo C; Coulthard, Paul; Worthington, Helen V; Riley, Philip; Patel, Neil; Darcey, James; Esposito, Marco; van der Elst, Maarten; van Waes, Oscar J F

    2014-11-28

    Sutures (stitches), staples and adhesive tapes have been used for many years as methods of wound closure, but tissue adhesives have entered clinical practice more recently. Closure of wounds with sutures enables the closure to be meticulous, but the sutures may show tissue reactivity and can require removal. Tissue adhesives offer the advantages of an absence of risk of needlestick injury and no requirement to remove sutures later. Initially, tissue adhesives were used primarily in emergency room settings, but this review looks at the use of tissue adhesives in the operating room/theatre where surgeons are using them increasingly for the closure of surgical skin incisions. To determine the effects of various tissue adhesives compared with conventional skin closure techniques for the closure of surgical wounds. In March 2014 for this second update we searched the Cochrane Wounds Group Specialised Register; The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library); Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid EMBASE and EBSCO CINAHL. We did not restrict the search and study selection with respect to language, date of publication or study setting. Only randomised controlled trials were eligible for inclusion. We conducted screening of eligible studies, data extraction and risk of bias assessment independently and in duplicate. We expressed results as random-effects models using mean difference for continuous outcomes and risk ratios (RR) with 95% confidence intervals (CI) for dichotomous outcomes. We investigated heterogeneity, including both clinical and methodological factors. This second update of the review identified 19 additional eligible trials resulting in a total of 33 studies (2793 participants) that met the inclusion criteria. There was low quality evidence that sutures were significantly better than tissue adhesives for reducing the risk of wound breakdown (dehiscence; RR 3.35; 95% CI 1.53 to 7.33; 10 trials, 736 participants that contributed data to the meta-analysis). The number needed to treat for an additional harmful outcome was calculated as 43. For all other outcomes - infection, patient and operator satisfaction and cost - there was no evidence of a difference for either sutures or tissue adhesives. No evidence of differences was found between tissue adhesives and tapes for minimising dehiscence, infection, patients' assessment of cosmetic appearance, patient satisfaction or surgeon satisfaction. However there was evidence in favour of using tape for surgeons' assessment of cosmetic appearance (mean difference (VAS 0 to 100) 9.56 (95% CI 4.74 to 14.37; 2 trials, 139 participants). One trial compared tissue adhesives with a variety of methods of wound closure and found both patients and clinicians were significantly more satisfied with the alternative closure methods than the adhesives. There appeared to be little difference in outcome for different types of tissue adhesives. One study that compared high viscosity with low viscosity adhesives found that high viscosity adhesives were less time-consuming to use than low viscosity tissue adhesives, but the time difference was small. Sutures are significantly better than tissue adhesives for minimising dehiscence. In some cases tissue adhesives may be quicker to apply than sutures. Although surgeons may consider the use of tissue adhesives as an alternative to other methods of surgical site closure in the operating theatre, they need to be aware that sutures minimise dehiscence. There is a need for more well designed randomised controlled trials comparing tissue adhesives with alternative methods of closure. These trials should include people whose health may interfere with wound healing and surgical sites of high tension.

  6. Microarray expression profiling in adhesion and normal peritoneal tissues.

    PubMed

    Ambler, Dana R; Golden, Alicia M; Gell, Jennifer S; Saed, Ghassan M; Carey, David J; Diamond, Michael P

    2012-05-01

    To identify molecular markers associated with adhesion and normal peritoneal tissue using microarray expression profiling. Comparative study. University hospital. Five premenopausal women. Adhesion and normal peritoneal tissue samples were obtained from premenopausal women. Ribonucleic acid was extracted using standard protocols and processed for hybridization to Affymetrix Whole Transcript Human Gene Expression Chips. Microarray data were obtained from five different patients, each with adhesion tissue and normal peritoneal samples. Real-time polymerase chain reaction was performed for confirmation using standard protocols. Gene expression in postoperative adhesion and normal peritoneal tissues. A total of 1,263 genes were differentially expressed between adhesion and normal tissues. One hundred seventy-three genes were found to be up-regulated and 56 genes were down-regulated in the adhesion tissues compared with normal peritoneal tissues. The genes were sorted into functional categories according to Gene Ontology annotations. Twenty-six up-regulated genes and 11 down-regulated genes were identified with functions potentially relevant to the pathophysiology of postoperative adhesions. We evaluated and confirmed expression of 12 of these specific genes via polymerase chain reaction. The pathogenesis, natural history, and optimal treatment of postoperative adhesive disease remains unanswered. Microarray analysis of adhesions identified specific genes with increased and decreased expression when compared with normal peritoneum. Knowledge of these genes and ontologic pathways with altered expression provide targets for new therapies to treat patients who have or are at risk for postoperative adhesions. Copyright © 2012 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  7. Laser physics and a review of laser applications in dentistry for children.

    PubMed

    Martens, L C

    2011-04-01

    The aim of this introduction to this special laser issue is to describe some basic laser physics and to delineate the potential of laser-assisted dentistry in children. A brief review of the available laser literature was performed within the scope of paediatric dentistry. Attention was paid to soft tissue surgery, caries prevention and diagnosis, cavity preparation, comfort of the patient, effect on bacteria, long term pulpal vitality, endodontics in primary teeth, dental traumatology and low level laser therapy. Although there is a lack of sufficient evidence taking into account the highest standards for evidence-based dentistry, it is clear that laser application in a number of different aetiologies for soft tissue surgery in children has proven to be successful. Lasers provide a refined diagnosis of caries combined with the appropriate preventive adhesive dentistry after cavity preparation. This will further lead to a new wave of micro-dentistry based on 'filling without drilling'. It has become clear from a review of the literature that specific laser applications in paediatric dentistry have gained increasing importance. It can be concluded that children should be considered as amongst the first patients for receiving laser-assisted dentistry.

  8. Tracking of Drug Release and Material Fate for Naturally Derived Omega-3 Fatty Acid Biomaterials.

    PubMed

    Faucher, Keith M; Artzi, Natalie; Beck, Moshe; Beckerman, Rita; Moodie, Geoff; Albergo, Theresa; Conroy, Suzanne; Dale, Alicia; Corbeil, Scott; Martakos, Paul; Edelman, Elazer R

    2016-03-01

    In vitro and in vivo studies were conducted on omega-3 fatty acid-derived biomaterials to determine their utility as an implantable material for adhesion prevention following soft tissue hernia repair and as a means to allow for the local delivery of antimicrobial or antibiofilm agents. Naturally derived biomaterials offer several advantages over synthetic materials in the field of medical device development. These advantages include enhanced biocompatibility, elimination of risks posed by the presence of toxic catalysts and chemical crosslinking agents, and derivation from renewable resources. Omega-3 fatty acids are readily available from fish and plant sources and can be used to create implantable biomaterials either as a stand-alone device or as a device coating that can be utilized in local drug delivery applications. In-depth characterization of material erosion degradation over time using non-destructive imaging and chemical characterization techniques provided mechanistic insight into material structure: function relationship. This in turn guided rational tailoring of the material based on varying fatty acid composition to control material residence time and hence drug release. These studies demonstrate the utility of omega-3 fatty acid derived biomaterials as an absorbable material for soft tissue hernia repair and drug delivery applications.

  9. Use of laser in orthodontics: applications and perspectives

    PubMed Central

    Fornaini, C; Merigo, E; Vescovi, P; Lagori, G; Rocca, JP

    2013-01-01

    Laser technology got in these years a more and more important role in modern dentistry and, recently, also in orthodontics was proposed the utilization of laser devices. The aim of this work is to describe the utilization of this technology both in soft and hard oral tissues to improve orthodontic treatment. Several cases, with different wavelengths (532, 810, 980, 1064, 2940 and 10600 nm) and in different times of the treatment (before, during and after) are presented. All the cases reported showed, according to the literature, that the use of the laser related to orthodontic treatment offers several advantages when compared with conventional methods. In the soft tissues surgery it allows to reduce or eliminate the use of anesthetic injection, to avoid use of sutures and to bond bracket in dry enamel; associated with orthophosphoric acid, it gives a stronger adhesion of the brackets to the enamel and, in the case of porcelain brackets, it detaches them without damages; at low power (LLLT) it permits to control the pain of the first period after bonding and, by increasing the speed of teeth movement in the bone, reduces the time of the treatment. PMID:24155556

  10. LC3-mediated fibronectin mRNA translation induces fibrosarcoma growth by increasing connective tissue growth factor

    PubMed Central

    Ying, Lihua; Lau, Agatha; Alvira, Cristina M.; West, Robert; Cann, Gordon M.; Zhou, Bin; Kinnear, Caroline; Jan, Eric; Sarnow, Peter; Van de Rijn, Matt; Rabinovitch, Marlene

    2009-01-01

    Summary Previously, we related fibronectin (Fn1) mRNA translation to an interaction between an AU-rich element in the Fn1 3′ UTR and light chain 3 (LC3) of microtubule-associated proteins 1A and 1B. Since human fibrosarcoma (HT1080) cells produce little fibronectin and LC3, we used these cells to investigate how LC3-mediated Fn1 mRNA translation might alter tumor growth. Transfection of HT1080 cells with LC3 enhanced fibronectin mRNA translation. Using polysome analysis and RNA-binding assays, we show that elevated levels of translation depend on an interaction between a triple arginine motif in LC3 and the AU-rich element in Fn1 mRNA. Wild-type but not mutant LC3 accelerated HT1080 cell growth in culture and when implanted in SCID mice. Comparison of WT LC3 with vector-transfected HT1080 cells revealed increased fibronectin-dependent proliferation, adhesion and invasion. Microarray analysis of genes differentially expressed in WT and vector-transfected control cells indicated enhanced expression of connective tissue growth factor (CTGF). Using siRNA, we show that enhanced expression of CTGF is fibronectin dependent and that LC3-mediated adhesion, invasion and proliferation are CTGF dependent. Expression profiling of soft tissue tumors revealed increased expression of both LC3 and CTGF in some locally invasive tumor types. PMID:19366727

  11. Studying Genes in Tissue Samples From Younger and Adolescent Patients With Soft Tissue Sarcomas

    ClinicalTrials.gov

    2016-05-13

    Childhood Alveolar Soft-part Sarcoma; Childhood Angiosarcoma; Childhood Desmoplastic Small Round Cell Tumor; Childhood Epithelioid Sarcoma; Childhood Fibrosarcoma; Childhood Leiomyosarcoma; Childhood Liposarcoma; Childhood Malignant Mesenchymoma; Childhood Neurofibrosarcoma; Childhood Synovial Sarcoma; Chordoma; Desmoid Tumor; Metastatic Childhood Soft Tissue Sarcoma; Nonmetastatic Childhood Soft Tissue Sarcoma; Recurrent Childhood Soft Tissue Sarcoma

  12. Soft tissue modelling with conical springs.

    PubMed

    Omar, Nadzeri; Zhong, Yongmin; Jazar, Reza N; Subic, Aleksandar; Smith, Julian; Shirinzadeh, Bijan

    2015-01-01

    This paper presents a new method for real-time modelling soft tissue deformation. It improves the traditional mass-spring model with conical springs to deal with nonlinear mechanical behaviours of soft tissues. A conical spring model is developed to predict soft tissue deformation with reference to deformation patterns. The model parameters are formulated according to tissue deformation patterns and the nonlinear behaviours of soft tissues are modelled with the stiffness variation of conical spring. Experimental results show that the proposed method can describe different tissue deformation patterns using one single equation and also exhibit the typical mechanical behaviours of soft tissues.

  13. Tissue adhesives for closure of surgical incisions.

    PubMed

    Coulthard, Paul; Esposito, Marco; Worthington, Helen V; van der Elst, Maarten; van Waes, Oscar J F; Darcey, James

    2010-05-12

    Sutures, staples and adhesive tapes are the traditional methods of wound closure, whilst tissue adhesives have entered clinical practice more recently. Closure of wounds with sutures enables meticulous closure, but they may show tissue reactivity and can require removal. Tissue adhesives offer the advantages of no risk of needlestick injury and no requirement to remove sutures later. Tissue adhesives have been used primarily in emergency rooms but this review looks at the use of tissue adhesives in the operating room where surgeons are increasingly using these for the closure of surgical skin incisions. To determine the relative effects of various tissue adhesives and conventional skin closure techniques on the healing of surgical wounds. For this update we searched the Cochrane Wounds Group Specialised Register (Searched 17/11/09); The Cochrane Central Register of Controlled Trials (CENTRAL) - The Cochrane Library Issue 4 2009; Ovid MEDLINE - 1950 to November Week 1 2009; Ovid EMBASE - 1980 to 2009 Week 46; EBSCO CINAHL - 1982 to 17 November 20098. No date or language restrictions were applied. Only randomised controlled clinical trials were eligible for inclusion. Screening of eligible studies and data extraction were conducted independently and in triplicate whilst assessment of the methodological quality of the trials was conducted independently and in duplicate. Results were expressed as random effects models using mean difference for continuous outcomes and relative risks with 95% confidence intervals for dichotomous outcomes. Heterogeneity was investigated including both clinical and methodological factors. This update identified an additional six trials resulting in a total of fourteen RCTs (1152 patients) which met the inclusion criteria. Sutures were significantly better than tissue adhesives for minimising dehiscence (10 trials). Sutures were also found to be significantly faster to use. For all other analyses of infection, patient and operator satisfaction and cost there was no significant difference between sutures and tissue adhesives. No differences were found between tissue adhesives and tapes (2 trials) for minimising dehiscence, infection, patients assessment of cosmetic appearance, patient satisfaction or surgeon satisfaction. However a statistically significant difference in favour of using tape was found for surgeons' assessment of cosmetic appearance (mean difference 13, 95% CI 5 to 21). Tapes were also demonstrated to be significantly faster to use than tissue adhesives as were staples (1 trial). No other outcome measures were analysed in this group. One trial compared tissue adhesives with a variety of methods of wound closure and found both patients and clinicians were significantly more satisfied with the alternative closure methods than the adhesives. In this same trial tissue adhesives were significantly less time consuming to use. For the remaining outcomes of dehiscence and infection no difference was observed between groups. This trial also compared high viscosity with low viscosity adhesives and found that high viscosity adhesives were less time consuming to use than low viscosity tissue adhesives. For all other outcomes of dehiscence, infection, patient satisfaction and operator satisfaction there was no statistically significant difference between high and low viscosity adhesives. Sutures were significantly better than tissue adhesives for minimising dehiscence and were found to be significantly faster to use. Although surgeons may consider the use of tissue adhesives as an alternative to other methods of surgical site closure in the operating theatre they must be aware that adhesives may take more time to apply and that if higher tension is needed upon an incision, sutures may minimise dehiscence. There is a need for more well designed randomised controlled trials comparing tissue adhesives and alternative methods of closure. These trials should include people whose health may interfere with wound healing and surgical sites of high tension.

  14. Fascial flap reconstruction of the hand: a single surgeon's 30-year experience.

    PubMed

    Carty, Matthew J; Taghinia, Amir; Upton, Joseph

    2010-03-01

    The reconstruction of complex hand wounds is challenging due to the requirements for thin and pliable coverage with a reliable vascular supply, potential for sensibility, and provision of a gliding surface. Fascial flaps represent an excellent option for the reconstruction of these complicated defects. A retrospective review of fascial flap reconstructive procedures to the hand undertaken by a single microsurgeon was performed for operations occurring between 1979 and 2009. Both pedicled and free tissue transfer procedures were included in both pediatric and adult patients. Data were culled from a combination of patient charts, hospital records, radiographic studies, and clinical photographs. Sixty fascial flap reconstructive procedures to the hand were analyzed in 60 patients from the defined 30-year period. The most common pathological process necessitating reconstruction was acute trauma (n = 32, 53 percent). Most of the soft-tissue injuries included in the study sample were located on the dorsal hand and wrist (n = 27, 45 percent). The most commonly utilized reconstructive modality was the temporoparietal fascial flap (n = 35, 58 percent). Most reconstructions were completed as free tissue transfers (n = 46, 77 percent). Perioperative complications were relatively minor; no flap losses were recorded. All cases studied demonstrated excellent long-term coverage with no evidence of underlying tendon adhesion or contracture. Fascial flaps represent an excellent option for coverage of soft-tissue defects of the hand that are not amenable to reconstruction with skin grafting alone, particularly for localized defects with denuded tendons or exposed joints.

  15. Soft Tissue Sarcoma—Health Professional Version

    Cancer.gov

    Soft tissue sarcomas are malignant tumors that arise in any of the mesodermal tissues of the extremities, trunk and retroperitoneum, or head and neck. Soft tissue sarcomas may be heterogeneous. Find evidence-based information on soft tissue sarcoma treatment and research.

  16. Epithelial-type and neural-type cadherin expression in malignant noncarcinomatous neoplasms with epithelioid features that involve the soft tissues.

    PubMed

    Laskin, William B; Miettinen, Markku

    2002-04-01

    Transmembrane adhesion molecules, epithelial-type cadherin (ECAD) and neural-type cadherin (NCAD), help in regulating transformations between epithelial and mesenchymal cells in the developing embryo and in maintaining the epithelioid phenotype. Consequently, the presence of epithelioid cells in certain malignant noncarcinomatous neoplasms raises speculation that the expression of ECAD and NCAD in these neoplasms may have diagnostic significance. To investigate the utility of ECAD and NCAD immunoexpression in distinguishing malignant (noncarcinomatous) neoplasms with epithelioid features that involve the soft tissues. Membranous immunoreactivity of anti-ECAD and anti-NCAD was evaluated on archived cases selected from the files of the Armed Forces Institute of Pathology. Epithelial-type cadherin was found in biphasic synovial sarcoma (35 of 35 cases), malignant melanoma (13/21), monophasic fibrous synovial sarcoma (13/26), clear cell sarcoma (4/9), poorly differentiated synovial sarcoma (3/13), diffuse mesothelioma (4/20), malignant epithelioid peripheral nerve sheath tumor (1/6), and epithelioid sarcoma (5/62). Neural-type cadherin was observed in chordoma (11/11), biphasic synovial sarcoma (30/35), diffuse mesothelioma (14/20), malignant melanoma (14/25), epithelioid sarcoma (24/63), epithelioid angiosarcoma (1/4), poorly differentiated synovial sarcoma (2/13), clear cell sarcoma (1/10), and monophasic fibrous synovial sarcoma (1/26). Eighteen cases of primary cutaneous squamous cell carcinomas all tested positive for ECAD, whereas NCAD was focally observed in 5 cases. No expression of either molecule was observed in cases of epithelioid hemangioendothelioma (n = 9), alveolar soft part sarcoma (n = 8), and extraskeletal myxoid chondrosarcoma (n = 7). Epithelial-type and neural-type cadherins are found in a variety of noncarcinomatous neoplasms with epithelioid features that involve the soft tissues and can be utilized, in association with other immunomarkers, in distinguishing chordoma (100% NCAD) from extraskeletal myxoid chondrosarcoma and conventional chondrosarcoma of bone (0% NCAD), squamous cell carcinoma (100% ECAD) from epithelioid sarcoma (8% ECAD), and biphasic synovial sarcoma (100% ECAD) from diffuse mesothelioma (20% ECAD).

  17. Soft material adhesion characterization for in vivo locomotion of robotic capsule endoscopes: Experimental and modeling results.

    PubMed

    Kern, Madalyn D; Ortega Alcaide, Joan; Rentschler, Mark E

    2014-11-01

    The objective of this work is to validate an experimental method and nondimensional model for characterizing the normal adhesive response between a polyvinyl chloride based synthetic biological tissue substrate and a flat, cylindrical probe with a smooth polydimethylsiloxane (PDMS) surface. The adhesion response is a critical mobility design parameter of a Robotic Capsule Endoscope (RCE) using PDMS treads to provide mobility to travel through the gastrointestinal tract for diagnostic purposes. Three RCE design characteristics were chosen as input parameters for the normal adhesion testing: pre-load, dwell time and separation rate. These parameters relate to the RCE׳s cross sectional dimension, tread length, and tread speed, respectively. An inscribed central composite design (CCD) prescribed 34 different parameter configurations to be tested. The experimental adhesion response curves were nondimensionalized by the maximum stress and total displacement values for each test configuration and a mean nondimensional curve was defined with a maximum relative error of 5.6%. A mathematical model describing the adhesion behavior as a function of the maximum stress and total displacement was developed and verified. A nonlinear regression analysis was done on the maximum stress and total displacement parameters and equations were defined as a function of the RCE design parameters. The nondimensional adhesion model is able to predict the adhesion curve response of any test configuration with a mean R(2) value of 0.995. Eight additional CCD studies were performed to obtain a qualitative understanding of the impact of tread contact area and synthetic material substrate stiffness on the adhesion response. These results suggest that the nondimensionalization technique for analyzing the adhesion data is sufficient for all values of probe radius and substrate stiffness within the bounds tested. This method can now be used for RCE tread design optimization given a set of environmental conditions for device operation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. The enhanced anti-tissue adhesive effect of injectable pluronic-HA hydrogel by poly(γ-glutamic acid).

    PubMed

    Kim, Manse; Hwang, Youngmin; Tae, Giyoong

    2016-12-01

    The stability of tissue barrier in physiological condition is a key factor to isolate the damaged site from adjacent tissue for anti-tissue adhesion. Although pluronic or pluronic-hyaluronic acid (HA) hydrogel as an injectable formulation can prevent tissue adhesion at the injection site, the anti-tissue adhesion effect is limited due to its poor stability. Herein, we prepared tissue barrier formulations composed of pluronic F127 (F127) and HA mixture (F127-HA) and the effect of the addition of poly(γ-glutamic acid) (PGA) was characterized. All of F127, HA, and F127-HA mixture showed the poor in vitro residence stability less than 3 days. However, by adding PGA into F127-HA mixture, their stability was significantly enhanced by the control of the molecular weight and concentration of PGA. Thus, F127-HA with 10wt% PGA (2000kDa) showed the long-term stability over 10 days. Similarly, the enhanced stability of F127-HA with PGA resulted in the enhanced and excellent in vivo anti-tissue adhesion effect, evidenced by histological analysis and grading of tissue adhesion. Therefore, F127-HA containing PGA could be applied as an efficient injectable tissue barrier for anti-tissue adhesion. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Programmable and Bidirectional Bending of Soft Actuators Based on Janus Structure with Sticky Tough PAA-Clay Hydrogel.

    PubMed

    Zhao, Lei; Huang, Jiahe; Zhang, Yuancheng; Wang, Tao; Sun, Weixiang; Tong, Zhen

    2017-04-05

    Facile preparation, rapid actuating, and versatile actions are great challenges in exploring new kinds of hydrogel actuators. In this paper, we presented a facile sticking method to prepare Janus bilayer and multilayer hydrogel actuators that benefited from a special tough and adhesive PAA-clay hydrogel. Combining physical and chemical cross-linking reagents, we endowed the PAA gel with both toughness and adhesion. This PAA gel was reinforced by further cross-linking with Fe 3+ . These two hydrogels with different cross-linking densities exhibited different swelling capabilities and moduli in the media manipulated by pH and ionic strength, thus acting as promising candidates for soft actuators. On the basis of these gels, we designed hydrogel actuators of rapid response in several minutes and precisely controlled actuating direction by sticking two hydrogel layers together. Elaborate soft actuators such as bidirectional bending flytrap, gel hand with grasp, open, and gesturing actions as well as word-writing actuator were prepared. This method could be generalized by using other stimuli-responsive hydrogels combined with the adhesive PAA gel, which would open a new way to programmable and versatile soft actuators.

  20. Hyaluronic acid based hydrogel system for soft tissue regeneration and drug delivery

    NASA Astrophysics Data System (ADS)

    Jha, Amit Kumar

    We have developed hyaluronic acid (HA)-based, biomimetic hydrogel matrices that are hierarchically structured, mechanically robust and biologically active. Specifically, HA-based hydrogel particles (HGPs) with controlled sizes, defined porosity, and improved stability were synthesized using different inverse emulsion systems and crosslinking chemistries. The resultant particles either contained residual functional groups or were rendered reactive by subsequent chemical modifications. HA-based doubly crosslinked networks (DXNs) were synthesized via covalent crosslinking of HA HGPs with soluble HA macromers carrying mutually reactive functional groups. These hybrid matrices are hierarchical in nature, consisting of densely crosslinked HGPs integrated in a loosely connected secondary matrix. Their mechanical properties and degradation kinetics can be readily tuned by varying the particle size, functional group density, intra- and interparticle crosslinking. To improve the biological functions of HA HGPs, perlecan domain I (PlnDI), a basement membrane proteoglycan that has strong affinity for various heparin binding growth factors (HBGFs), was successfully conjugated to the particles through the core protein via a flexible poly(ethylene glycol) (PEG) linker. The immobilized PlnDI maintains its ability to bind bone morphogenetic proteins (BMP-2) and modulates its in vitro release. A similar, sustained release of BMP-2 was achieved by encapsulating BMP-2-loaded HGPs within a photocrosslinked HA matrix. When encapsulated in HA DXNs, primary bovine chondrocytes were able to maintain their phenotype, proliferate readily and produce abundant glycosaminoglycan. Finally, cell-adhesive HA DXNs were fabricated by encapsulating gelatin-decorated HA HGPs in a secondary HA matrix. Human MSCs were shown to adhere to the composite matrix through the focal adhesion sites clustered on particle surface. The cell-adhesive composite matrices supported hMSC proliferation and migration into the gels. Human MSCs were undifferentiated during the early time points of culture, however differentiated into osteoblast phenotype after 28 days of culture. In summary, the HA-based hydrogel matrices are hierarchically structured, mechanically robust and enzymatically stable, capable of mediating cellular functions through the spatial and temporal presentation of defined biological cues. These hydrogel systems are promising candidates for soft tissue regeneration.

  1. UV-cured adhesives for carbon fiber composite applications

    NASA Astrophysics Data System (ADS)

    Lu, Hsiao-Chun

    Carbon fiber composite materials are increasingly used in automobile, marine, and aerospace industries due to their unique properties, including high strength, high stiffness and low weight. However, due to their brittle characteristic, these structures are prone to physical damage, such as a bird strike or impact damage. Once the structure is damaged, it is important to have fast and reliable temporary repair until the permanent repair or replacement can take place. In this dissertation, UV-based adhesives were used to provide a bonding strength for temporary repair. Adhesively bonded patch repair is an efficient and effective method for temporary repair. In this study, precured patches (hard patches) and dry fabric patches with laminating resins (soft patches) were performed. UV-based epoxy adhesives were applied to both patch repair systems. For precured patch repair, the bonding strengths were investigated under different surface treatments for bonding area and different adhesives thicknesses. The shear stresses of different UV exposure times and curing times were tested. Besides, the large patch repair was investigated as well. For soft patch repair, the hand wet lay-up was applied due to high viscosity of UV resins. A modified single lap shear testing (ASTM D5868) was applied to determine the shear stress. The large patches used fiber glass instead of carbon fiber to prove the possibility of repair with UV epoxy resin by hand wet lay-up process. The hand lay-up procedure was applied and assisted by vacuum pressure to eliminate the air bubbles and consolidate the patches. To enhance the bonding strength and effective soft patch repair, vacuum assisted resin transferring molding (VaRTM) is the better option. However, only low viscosity resins can be operated by VaRTM. Hence, new UV-based adhesives were formulated. The new UV-based adhesives included photoinitiator (PI), epoxy and different solvents. Solvents were used to compound the photoinitiator into epoxy monomer. Acetone, tetrahydrofuran (THF) and chloroform were used as well as their anhydrous solvents. The UV exposure times and curing times of new UV-based resins were tested. FT-IR, DSC and DMA were used to investigate structure, glass transition temperatures(Tg) and properties of polymer. In summary, the UV-based adhesive was applied to adhesively bonded hard patch and soft patch repair. In addition, new UV-based resins were formulated for the VaRTM process. The in-field repair can be effective and efficient by using UV adhesives.

  2. The Primer for Sports Medicine Professionals on Imaging

    PubMed Central

    Farshad-Amacker, Nadja A.; Jain Palrecha, Sapna; Farshad, Mazda

    2013-01-01

    Because of its inherent superior soft tissue contrast and lack of ionizing radiation, magnetic resonance imaging (MRI) is highly suited to study the complex anatomy of the shoulder joint, particularly when assessing the relatively high incidence of shoulder injuries in young, athletic patients. This review aims to serve as a primer for understanding shoulder MRI in an algorithmical approach, including MRI protocol and technique, normal anatomy and anatomical variations of the shoulder, pathologic conditions of the rotator cuff tendons and muscles, the long head of the biceps tendon, shoulder impingement, labral and glenohumeral ligament pathology, MR findings in shoulder instability, adhesive capsulitis, and osteoarthritis. PMID:24381700

  3. Necrotizing soft tissue infection

    MedlinePlus

    Necrotizing fasciitis; Fasciitis - necrotizing; Flesh-eating bacteria; Soft tissue gangrene; Gangrene - soft tissue ... Many different types of bacteria can cause this infection. A very severe and usually deadly form of necrotizing soft tissue infection is due to the ...

  4. Interventional Pain Management in Rheumatological Diseases - A Three Years Physiatric Experience in a Tertiary Medical College Hospital in Bangladesh

    PubMed Central

    Hasan, Suzon Al; Das, Gautam; Khan, Amin Uddin A

    2011-01-01

    Background Interventional pain management (IPM) is a branch of medical science that deals with management of painful medical conditions using specially equipped X-ray machines and anatomical landmarks. Interventional physiatry is a branch of physical medicine and rehabilitation that treats painful conditions through intervention in peripheral joints, the spine, and soft tissues. Methods A cross-sectional study was conducted using three years of hospital records (2006 to 2008) from the Physical Medicine and Rehabilitation Department at Chittagong Medical College Hospital in Bangladesh, with a view toward highlighting current interventional pain practice in a tertiary medical college hospital. Results The maximum amount of intervention was done in degenerative peripheral joint disorders (600, 46.0%), followed by inflammatory joint diseases (300, 23.0%), soft tissue rheumatism (300, 23.0%), and radicular or referred lower back conditions (100, 8.0%). Of the peripheral joints, the knee was the most common site of intervention. Motor stimulation-guided intralesional injection of methylprednisolone into the piriformis muscle was given in 10 cases of piriformis syndrome refractory to both oral medications and therapeutic exercises. Soft tissue rheumatism of unknown etiology was most common in the form of adhesive capsulitis (90, 64.3%), and is discussed separately. Epidural steroid injection was practiced for various causes of lumbar radiculopathy, with the exception of infective discitis. Conclusions All procedures were performed using anatomical landmarks, as there were no facilities for the C-arm/diagnostic ultrasound required for accurate and safe intervention. A dedicated IPM setup should be a requirement in all PMR departments, to provide better pain management and to reduce the burden on other specialties. PMID:22220242

  5. Downregulation of SS18-SSX1 expression in synovial sarcoma by small interfering RNA enhances the focal adhesion pathway and inhibits anchorage-independent growth in vitro and tumor growth in vivo.

    PubMed

    Takenaka, Satoshi; Naka, Norifumi; Araki, Nobuhito; Hashimoto, Nobuyuki; Ueda, Takafumi; Yoshioka, Kiyoko; Yoshikawa, Hideki; Itoh, Kazuyuki

    2010-04-01

    Synovial sarcoma (SS) is an aggressive soft-tissue malignancy characterized by a unique t(X;18) translocation resulting in expression of SS18-SSX fusion protein. In order to investigate the biological function of this fusion protein and to develop a novel therapeutic option, we examined downregulation of SS18-SSX1 expression by small interfering RNA targeting SS18-SSX1 in three human SS cell lines. Microarray analysis comparing SS18-SSX1-silenced cells with control cells in three SS cell lines showed that SS18-SSX1 mainly affected the focal adhesion pathway. In accord with the array data, silencing of SS18-SSX1 enhances adhesion to the extracellular matrix through the induction of expression of myosin light-chain kinase. Furthermore, the silencing of SS18-SSX1 inhibits anchorage-independent growth in vitro and systemic delivery of siRNA against SS18-SSX1 using a nanoparticle system inhibited tumor growth in a nude mouse xenograft model. Our results demonstrate that siRNA targeting of SS18-SSX1 has therapeutic potential for the treatment of SS.

  6. SU-E-T-409: Evaluation of Tissue Composition Effect On Dose Distribution in Radiotherapy with 6 MV Photon Beam of a Medical Linac

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ghorbani, M; Tabatabaei, Z; Noghreiyan, A Vejdani

    Purpose: The aim of this study is to evaluate soft tissue composition effect on dose distribution for various soft tissues and various depths in radiotherapy with 6 MV photon beam of a medical linac. Methods: A phantom and Siemens Primus linear accelerator were simulated using MCNPX Monte Carlo code. In a homogeneous cubic phantom, six types of soft tissue and three types of tissue-equivalent materials were defined separately. The soft tissues were muscle (skeletal), adipose tissue, blood (whole), breast tissue, soft tissue (9-component) and soft tissue (4-component). The tissue-equivalent materials included: water, A-150 tissue-equivalent plastic and perspex. Photon dose relativemore » to dose in 9-component soft tissue at various depths on the beam’s central axis was determined for the 6 MV photon beam. The relative dose was also calculated and compared for various MCNPX tallies including,F8, F6 and,F4. Results: The results of the relative photon dose in various materials relative to dose in 9-component soft tissue and using different tallies are reported in the form of tabulated data. Minor differences between dose distributions in various soft tissues and tissue-equivalent materials were observed. The results from F6 and F4 were practically the same but different with,F8 tally. Conclusion: Based on the calculations performed, the differences in dose distributions in various soft tissues and tissue-equivalent materials are minor but they could be corrected in radiotherapy calculations to upgrade the accuracy of the dosimetric calculations.« less

  7. Soft tissue wound healing at teeth, dental implants and the edentulous ridge when using barrier membranes, growth and differentiation factors and soft tissue substitutes.

    PubMed

    Vignoletti, Fabio; Nunez, Javier; Sanz, Mariano

    2014-04-01

    To review the biological processes of wound healing following periodontal and periimplant plastic surgery when different technologies are used in a) the coverage of root and implant dehiscences, b) the augmentation of keratinized tissue (KT) and c) the augmentation of soft tissue volume. An electronic search from The National Library of Medicine (MEDLINE-PubMed) was performed: English articles with research focus in oral soft tissue regeneration, providing histological outcomes, either from animal experimental studies or human biopsy material were included. Barrier membranes, enamel matrix derivatives, growth factors, allogeneic and xenogeneic soft tissue substitutes have been used in soft tissue regeneration demonstrating different degrees of regeneration. In root coverage, these technologies were able to improve new attachment, although none has shown complete regeneration. In KT augmentation, tissue-engineered allogenic products and xenogeneic collagen matrixes demonstrated integration within the host connective tissue and promotion of keratinization. In soft tissue augmentation and peri-implant plastic surgery there are no histological data currently available. Soft tissue substitutes, growth differentiation factors demonstrated promising histological results in terms of soft tissue regeneration and keratinization, whereas there is a need for further studies to prove their added value in soft tissue augmentation. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Soft tissue deformation modelling through neural dynamics-based reaction-diffusion mechanics.

    PubMed

    Zhang, Jinao; Zhong, Yongmin; Gu, Chengfan

    2018-05-30

    Soft tissue deformation modelling forms the basis of development of surgical simulation, surgical planning and robotic-assisted minimally invasive surgery. This paper presents a new methodology for modelling of soft tissue deformation based on reaction-diffusion mechanics via neural dynamics. The potential energy stored in soft tissues due to a mechanical load to deform tissues away from their rest state is treated as the equivalent transmembrane potential energy, and it is distributed in the tissue masses in the manner of reaction-diffusion propagation of nonlinear electrical waves. The reaction-diffusion propagation of mechanical potential energy and nonrigid mechanics of motion are combined to model soft tissue deformation and its dynamics, both of which are further formulated as the dynamics of cellular neural networks to achieve real-time computational performance. The proposed methodology is implemented with a haptic device for interactive soft tissue deformation with force feedback. Experimental results demonstrate that the proposed methodology exhibits nonlinear force-displacement relationship for nonlinear soft tissue deformation. Homogeneous, anisotropic and heterogeneous soft tissue material properties can be modelled through the inherent physical properties of mass points. Graphical abstract Soft tissue deformation modelling with haptic feedback via neural dynamics-based reaction-diffusion mechanics.

  9. Tribology of bio-inspired nanowrinkled films on ultrasoft substrates.

    PubMed

    Lackner, Juergen M; Waldhauser, Wolfgang; Major, Lukasz; Teichert, Christian; Hartmann, Paul

    2013-01-01

    Biomimetic design of new materials uses nature as antetype, learning from billions of years of evolution. This work emphasizes the mechanical and tribological properties of skin, combining both hardness and wear resistance of its surface (the stratum corneum) with high elasticity of the bulk (epidermis, dermis, hypodermis). The key for combination of such opposite properties is wrinkling, being consequence of intrinsic stresses in the bulk (soft tissue): Tribological contact to counterparts below the stress threshold for tissue trauma occurs on the thick hard stratum corneum layer pads, while tensile loads smooth out wrinkles in between these pads. Similar mechanism offers high tribological resistance to hard films on soft, flexible polymers, which is shown for diamond-like carbon (DLC) and titanium nitride thin films on ultrasoft polyurethane and harder polycarbonate substrates. The choice of these two compared substrate materials will show that ultra-soft substrate materials are decisive for the distinct tribological material. Hierarchical wrinkled structures of films on these substrates are due to high intrinsic compressive stress, which evolves during high energetic film growth. Incremental relaxation of these stresses occurs by compound deformation of film and elastic substrate surface, appearing in hierarchical nano-wrinkles. Nano-wrinkled topographies enable high elastic deformability of thin hard films, while overstressing results in zigzag film fracture along larger hierarchical wrinkle structures. Tribologically, these fracture mechanisms are highly important for ploughing and sliding of sharp and flat counterparts on hard-coated ultra-soft substrates like polyurethane. Concentration of polyurethane deformation under the applied normal loads occurs below these zigzag cracks. Unloading closes these cracks again. Even cyclic testing do not lead to film delamination and retain low friction behavior, if the adhesion to the substrate is high and the initial friction coefficient of the film against the sliding counterpart low, e.g. found for DLC.

  10. Quiescence of human muscle stem cells is favored by culture on natural biopolymeric films.

    PubMed

    Monge, Claire; DiStasio, Nicholas; Rossi, Thomas; Sébastien, Muriel; Sakai, Hiroshi; Kalman, Benoit; Boudou, Thomas; Tajbakhsh, Shahragim; Marty, Isabelle; Bigot, Anne; Mouly, Vincent; Picart, Catherine

    2017-05-02

    Satellite cells are quiescent resident muscle stem cells that present an important potential to regenerate damaged tissue. However, this potential is diminished once they are removed from their niche environment in vivo, prohibiting the long-term study and genetic investigation of these cells. This study therefore aimed to provide a novel biomaterial platform for the in-vitro culture of human satellite cells that maintains their stem-like quiescent state, an important step for cell therapeutic studies. Human muscle satellite cells were isolated from two donors and cultured on soft biopolymeric films of controlled stiffness. Cell adhesive phenotype, maintenance of satellite cell quiescence and capacity for gene manipulation were investigated using FACS, western blotting, fluorescence microscopy and electron microscopy. About 85% of satellite cells cultured in vitro on soft biopolymer films for 3 days maintained expression of the quiescence marker Pax7, as compared with 60% on stiffer films and 50% on tissue culture plastic. The soft biopolymeric films allowed satellite cell culture for up to 6 days without renewing the media. These cells retained their stem-like properties, as evidenced by the expression of stem cell markers and reduced expression of differentiated markers. In addition, 95% of cells grown on these soft biopolymeric films were in the G0/G1 stage of the cell cycle, as opposed to those grown on plastic that became activated and began to proliferate and differentiate. Our study identifies a new biomaterial made of a biopolymer thin film for the maintenance of the quiescence state of muscle satellite cells. These cells could be activated at any point simply by replating them onto a plastic culture dish. Furthermore, these cells could be genetically manipulated by viral transduction, showing that this biomaterial may be further used for therapeutic strategies.

  11. Tribology of bio-inspired nanowrinkled films on ultrasoft substrates

    PubMed Central

    Lackner, Juergen M.; Waldhauser, Wolfgang; Major, Lukasz; Teichert, Christian; Hartmann, Paul

    2013-01-01

    Biomimetic design of new materials uses nature as antetype, learning from billions of years of evolution. This work emphasizes the mechanical and tribological properties of skin, combining both hardness and wear resistance of its surface (the stratum corneum) with high elasticity of the bulk (epidermis, dermis, hypodermis). The key for combination of such opposite properties is wrinkling, being consequence of intrinsic stresses in the bulk (soft tissue): Tribological contact to counterparts below the stress threshold for tissue trauma occurs on the thick hard stratum corneum layer pads, while tensile loads smooth out wrinkles in between these pads. Similar mechanism offers high tribological resistance to hard films on soft, flexible polymers, which is shown for diamond-like carbon (DLC) and titanium nitride thin films on ultrasoft polyurethane and harder polycarbonate substrates. The choice of these two compared substrate materials will show that ultra-soft substrate materials are decisive for the distinct tribological material. Hierarchical wrinkled structures of films on these substrates are due to high intrinsic compressive stress, which evolves during high energetic film growth. Incremental relaxation of these stresses occurs by compound deformation of film and elastic substrate surface, appearing in hierarchical nano-wrinkles. Nano-wrinkled topographies enable high elastic deformability of thin hard films, while overstressing results in zigzag film fracture along larger hierarchical wrinkle structures. Tribologically, these fracture mechanisms are highly important for ploughing and sliding of sharp and flat counterparts on hard-coated ultra-soft substrates like polyurethane. Concentration of polyurethane deformation under the applied normal loads occurs below these zigzag cracks. Unloading closes these cracks again. Even cyclic testing do not lead to film delamination and retain low friction behavior, if the adhesion to the substrate is high and the initial friction coefficient of the film against the sliding counterpart low, e.g. found for DLC. PMID:24688710

  12. Adhesive complex coacervate inspired by the sandcastle worm as a sealant for fetoscopic defects

    NASA Astrophysics Data System (ADS)

    Kaur, Sarbjit

    Inspired by the Sandcastle Worm, biomimetic of the water-borne adhesive was developed by complex coacervation of the synthetic copolyelectrolytes, mimicking the chemistries of the worm glue. The developed underwater adhesive was designed for sealing fetal membranes after fetoscopic surgery in twin-to-twin transfusion syndrome (TTTS) and sealing neural tissue of a fetus in aminiotic sac for spina bifida condition. Complex coacervate with increased bond strength was created by entrapping polyethylene glycol diacrylate (PEG-dA) monomer within the cross-linked coacervate network. Maximum shear bond strength of ~ 1.2 MPa on aluminum substrates was reached. The monomer-filled coacervate had complex flow behavior, thickening at low shear rates and then thinning suddenly with a 16-fold drop in viscosity at shear rates near 6 s-1. The microscale structure of the complex coacervates resembled a three-dimensional porous network of interconnected tubules. This complex coacervate adhesive was used in vitro studies to mimic the uterine wall-fetal membrane interface using a water column with one end and sealed with human fetal membranes and poultry breast, and a defect was created with an 11 French trocar. The coacervate adhesive in conjunction with the multiphase adhesive was used to seal the defect. The sealant withstood an additional traction of 12 g for 30-60 minutes and turbulence of the water column without leakage of fluid or slippage. The adhesive is nontoxic when in direct contact with human fetal membranes in an organ culture setting. A stable complex coacervate adhesive for long-term use in TTTS and spina bifida application was developed by methacrylating the copolyelectrolytes. The methacrylated coacervate was crosslinked chemically for TTTS and by photopolymerization for spina bifida. Tunable mechanical properties of the adhesive were achieved by varying the methacrylation of the polymers. Varying the amine to phosphate (A/P) ratio in the coacervate formation generated a range of viscosities. The chemically cured complex coacervate, with sodium (meta) periodate crosslinker, was tested in pig animal studies, showing promising results. The adhesive adhered to the fetal membrane tissue, with maximum strength of 473 +/- 82 KPa on aluminum substrates. The elastic modulus increased with increasing methacrylation on both the polyphosphate and polyamine within the coacervate. Photopolymerized complex coacervate adhesive was photocured using Eosin-Y and treiethanolamine photoinitiators, using a green laser diode. Soft substrate bond strength increased with increasing PEG-dA concentration to a maximum of ~90 kPa. The crosslinked complex coacervate adhesives with PEG networks swelled less than 5% over 30 days in physiological conditions. The sterile glue was nontoxic, deliverable through a fine cannula, and stable over a long time period. Preliminary animal studies show a novel innovative method to seal fetal membrane defects in humans, in utero.

  13. Soft Tissue Alterations in Esthetic Postextraction Sites: A 3-Dimensional Analysis.

    PubMed

    Chappuis, V; Engel, O; Shahim, K; Reyes, M; Katsaros, C; Buser, D

    2015-09-01

    Dimensional alterations of the facial soft and bone tissues following tooth extraction in the esthetic zone play an essential role to achieve successful outcomes in implant therapy. This prospective study is the first to investigate the interplay between the soft tissue dimensions and the underlying bone anatomy during an 8-wk healing period. The analysis is based on sequential 3-dimensional digital surface model superimpositions of the soft and bone tissues using digital impressions and cone beam computed tomography during an 8-wk healing period. Soft tissue thickness in thin and thick bone phenotypes at extraction was similar, averaging 0.7 mm and 0.8 mm, respectively. Interestingly, thin bone phenotypes revealed a 7-fold increase in soft tissue thickness after an 8-wk healing period, whereas in thick bone phenotypes, the soft tissue dimensions remained unchanged. The observed spontaneous soft tissue thickening in thin bone phenotypes resulted in a vertical soft tissue loss of only 1.6 mm, which concealed the underlying vertical bone resorption of 7.5 mm. Because of spontaneous soft tissue thickening, no significant differences were detected in the total tissue loss between thin and thick bone phenotypes at 2, 4, 6, and 8 wk. More than 51% of these dimensional alterations occurred within 2 wk of healing. Even though the observed spontaneous soft tissue thickening in thin bone phenotypes following tooth extraction conceals the pronounced underlying bone resorption pattern by masking the true bone deficiency, spontaneous soft tissue thickening offers advantages for subsequent bone regeneration and implant therapies in sites with high esthetic demand (Clinicaltrials.gov NCT02403700). © International & American Associations for Dental Research.

  14. Cone-Beam Computed Tomography Evaluation of Horizontal and Vertical Dimensional Changes in Buccal Peri-Implant Alveolar Bone and Soft Tissue: A 1-Year Prospective Clinical Study.

    PubMed

    Kaminaka, Akihiro; Nakano, Tamaki; Ono, Shinji; Kato, Tokinori; Yatani, Hirofumi

    2015-10-01

    This study evaluated changes in the horizontal and vertical dimensions of the buccal alveolar bone and soft tissue over a 1-year period following implant prosthesis. Thirty-three participants with no history of guided bone regeneration or soft tissue augmentation underwent dental implant placement with different types of connections. The dimensions of the buccal alveolar bone and soft tissue were evaluated immediately and at 1 year after prosthesis from reconstructions of cross-sectional cone-beam computed tomography images. The vertical and horizontal loss of buccal bone and soft tissue around implants with conical connections were lower than around those with external or internal connections. Statistically significant negative correlations were observed between initial horizontal bone thickness and changes in vertical bone and soft tissue height (p < .05), and between initial horizontal soft tissue thickness and the change in vertical soft tissue height (p < .05). Implants with a conical connection preserve peri-implant alveolar bone and soft tissue more effectively than other connection types. Furthermore, the initial buccal alveolar bone and soft tissue thickness around the implant platform may influence their vertical dimensional changes at 1 year after implant prosthesis. © 2014 Wiley Periodicals, Inc.

  15. Facile Synthesis of Conductive Polypyrrole Wrinkle Topographies on Polydimethylsiloxane via a Swelling-Deswelling Process and Their Potential Uses in Tissue Engineering.

    PubMed

    Aufan, M Rifqi; Sumi, Yang; Kim, Semin; Lee, Jae Young

    2015-10-28

    Electrically conducting biomaterials have gained great attention in various biomedical studies especially to influence cell and tissue responses. In addition, wrinkling can present a unique topography that can modulate cell-material interactions. In this study, we developed a simple method to create wrinkle topographies of conductive polypyrrole (wPPy) on soft polydimethylsiloxane surfaces via a swelling-deswelling process during and after PPy polymerization and by varying the thickness of the PPy top layers. As a result, various features of wPPy in the range of the nano- and microscales were successfully obtained. In vitro cell culture studies with NIH 3T3 fibroblasts and PC12 neuronal cells indicated that the conductive wrinkle topographies promote cell adhesion and neurite outgrowth of PC12 cells. Our studies help to elucidate the design of the surface coating and patterning of conducting polymers, which will enable us to simultaneously provide topographical and electrical signals to improve cell-surface interactions for potential tissue-engineering applications.

  16. Various Surface Treatments to Implant Provisional Restorations and Their Effect on Epithelial Cell Adhesion: A Comparative In Vitro Study.

    PubMed

    Luchinskaya, Darya; Du, Rong; Owens, David M; Tarnow, Dennis; Bittner, Nurit

    2017-02-01

    The aim of this in vitro study was to investigate the ability of epithelial cells to attach to or proliferate on various mechanical or chemical surface treatments of an implant provisional material. Polyethyl methacrylate discs 10 mm in diameter and ∼0.2 to 0.75 mm in width were used in the study. Experimental discs were treated with either a mechanical (pumice, varnish for shine, or high polishing) or a chemical agent (alcohol, chlorhexidine, or steam) to provide cleaning and/or polishing. Using primary human epidermal keratinocytes, experiments were performed to test the adhesion or proliferation of cells on the discs with various surface treatments. Scanning electron microscope analysis, rhodamine staining, and cell counting using a hemocytometer corroborated all findings and illustrated that the highest cell adhesion was found to be in the smooth surface treatment groups and the poorest adhesion was found to be in the rough surface groups and chemical treatment group. Within the limitations of this study, the following clinical protocol is recommended for finishing, polishing, and disinfecting implant provisional restorations: coarse, medium, fine pumice → high polishing (if desired) → steam. It is recommended to avoid applying varnish in the perimucosal area near the epithelium. This study could establish the most appropriate way to handle provisional restorations in the peri-implant sulcus for improved soft tissue health, esthetics, and long-term stability.

  17. Towards the modeling of nanoindentation of virus shells: Do substrate adhesion and geometry matter?

    NASA Astrophysics Data System (ADS)

    Bousquet, Arthur; Dragnea, Bogdan; Tayachi, Manel; Temam, Roger

    2016-12-01

    Soft nanoparticles adsorbing at surfaces undergo deformation and buildup of elastic strain as a consequence of interfacial adhesion of similar magnitude with constitutive interactions. An example is the adsorption of virus particles at surfaces, a phenomenon of central importance for experiments in virus nanoindentation and for understanding of virus entry. The influence of adhesion forces and substrate corrugation on the mechanical response to indentation has not been studied. This is somewhat surprising considering that many single-stranded RNA icosahedral viruses are organized by soft intermolecular interactions while relatively strong adhesion forces are required for virus immobilization for nanoindentation. This article presents numerical simulations via finite elements discretization investigating the deformation of a thick shell in the context of slow evolution linear elasticity and in presence of adhesion interactions with the substrate. We study the influence of the adhesion forces in the deformation of the virus model under axial compression on a flat substrate by comparing the force-displacement curves for a shell having elastic constants relevant to virus capsids with and without adhesion forces derived from the Lennard-Jones potential. Finally, we study the influence of the geometry of the substrate in two-dimensions by comparing deformation of the virus model adsorbed at the cusp between two cylinders with that on a flat surface.

  18. Dietary sodium, adiposity, and inflammation in healthy adolescents.

    PubMed

    Zhu, Haidong; Pollock, Norman K; Kotak, Ishita; Gutin, Bernard; Wang, Xiaoling; Bhagatwala, Jigar; Parikh, Samip; Harshfield, Gregory A; Dong, Yanbin

    2014-03-01

    To determine the relationships of sodium intake with adiposity and inflammation in healthy adolescents. A cross-sectional study involved 766 healthy white and African American adolescents aged 14 to 18 years. Dietary sodium intake was estimated by 7-day 24-hour dietary recall. Percent body fat was measured by dual-energy x-ray absorptiometry. Subcutaneous abdominal adipose tissue and visceral adipose tissue were assessed using magnetic resonance imaging. Fasting blood samples were measured for leptin, adiponectin, C-reactive protein, tumor necrosis factor-α, and intercellular adhesion molecule-1. The average sodium intake was 3280 mg/day. Ninety-seven percent of our adolescents exceeded the American Heart Association recommendation for sodium intake. Multiple linear regressions revealed that dietary sodium intake was independently associated with body weight (β = 0.23), BMI (β = 0.23), waist circumference (β = 0.23), percent body fat (β = 0.17), fat mass (β = 0.23), subcutaneous abdominal adipose tissue (β = 0.25), leptin (β = 0.20), and tumor necrosis factor-α (β = 0.61; all Ps < .05). No relation was found between dietary sodium intake and visceral adipose tissue, skinfold thickness, adiponectin, C-reactive protein, or intercellular adhesion molecule-1. All the significant associations persisted after correction for multiple testing (all false discovery rates < 0.05). The mean sodium consumption of our adolescents is as high as that of adults and more than twice the daily intake recommended by the American Heart Association. High sodium intake is positively associated with adiposity and inflammation independent of total energy intake and sugar-sweetened soft drink consumption.

  19. Dietary Sodium, Adiposity, and Inflammation in Healthy Adolescents

    PubMed Central

    Pollock, Norman K.; Kotak, Ishita; Gutin, Bernard; Wang, Xiaoling; Bhagatwala, Jigar; Parikh, Samip; Harshfield, Gregory A.; Dong, Yanbin

    2014-01-01

    OBJECTIVES: To determine the relationships of sodium intake with adiposity and inflammation in healthy adolescents. METHODS: A cross-sectional study involved 766 healthy white and African American adolescents aged 14 to 18 years. Dietary sodium intake was estimated by 7-day 24-hour dietary recall. Percent body fat was measured by dual-energy x-ray absorptiometry. Subcutaneous abdominal adipose tissue and visceral adipose tissue were assessed using magnetic resonance imaging. Fasting blood samples were measured for leptin, adiponectin, C-reactive protein, tumor necrosis factor-α, and intercellular adhesion molecule-1. RESULTS: The average sodium intake was 3280 mg/day. Ninety-seven percent of our adolescents exceeded the American Heart Association recommendation for sodium intake. Multiple linear regressions revealed that dietary sodium intake was independently associated with body weight (β = 0.23), BMI (β = 0.23), waist circumference (β = 0.23), percent body fat (β = 0.17), fat mass (β = 0.23), subcutaneous abdominal adipose tissue (β = 0.25), leptin (β = 0.20), and tumor necrosis factor-α (β = 0.61; all Ps < .05). No relation was found between dietary sodium intake and visceral adipose tissue, skinfold thickness, adiponectin, C-reactive protein, or intercellular adhesion molecule-1. All the significant associations persisted after correction for multiple testing (all false discovery rates < 0.05). CONCLUSIONS: The mean sodium consumption of our adolescents is as high as that of adults and more than twice the daily intake recommended by the American Heart Association. High sodium intake is positively associated with adiposity and inflammation independent of total energy intake and sugar-sweetened soft drink consumption. PMID:24488738

  20. Validation of a Radiography-Based Quantification Designed to Longitudinally Monitor Soft Tissue Calcification in Skeletal Muscle.

    PubMed

    Moore, Stephanie N; Hawley, Gregory D; Smith, Emily N; Mignemi, Nicholas A; Ihejirika, Rivka C; Yuasa, Masato; Cates, Justin M M; Liu, Xulei; Schoenecker, Jonathan G

    2016-01-01

    Soft tissue calcification, including both dystrophic calcification and heterotopic ossification, may occur following injury. These lesions have variable fates as they are either resorbed or persist. Persistent soft tissue calcification may result in chronic inflammation and/or loss of function of that soft tissue. The molecular mechanisms that result in the development and maturation of calcifications are uncertain. As a result, directed therapies that prevent or resorb soft tissue calcifications remain largely unsuccessful. Animal models of post-traumatic soft tissue calcification that allow for cost-effective, serial analysis of an individual animal over time are necessary to derive and test novel therapies. We have determined that a cardiotoxin-induced injury of the muscles in the posterior compartment of the lower extremity represents a useful model in which soft tissue calcification develops remote from adjacent bones, thereby allowing for serial analysis by plain radiography. The purpose of the study was to design and validate a method for quantifying soft tissue calcifications in mice longitudinally using plain radiographic techniques and an ordinal scoring system. Muscle injury was induced by injecting cardiotoxin into the posterior compartment of the lower extremity in mice susceptible to developing soft tissue calcification. Seven days following injury, radiographs were obtained under anesthesia. Multiple researchers applied methods designed to standardize post-image processing of digital radiographs (N = 4) and quantify soft tissue calcification (N = 6) in these images using an ordinal scoring system. Inter- and intra-observer agreement for both post-image processing and the scoring system used was assessed using weighted kappa statistics. Soft tissue calcification quantifications by the ordinal scale were compared to mineral volume measurements (threshold 450.7mgHA/cm3) determined by μCT. Finally, sample-size calculations necessary to discriminate between a 25%, 50%, 75%, and 100% difference in STiCSS score 7 days following burn/CTX induced muscle injury were determined. Precision analysis demonstrated substantial to good agreement for both post-image processing (κ = 0.73 to 0.90) and scoring (κ = 0.88 to 0.93), with low inter- and intra-observer variability. Additionally, there was a strong correlation in quantification of soft tissue calcification between the ordinal system and by mineral volume quantification by μCT (Spearman r = 0.83 to 0.89). The ordinal scoring system reliably quantified soft tissue calcification in a burn/CTX-induced soft tissue calcification model compared to non-injured controls (Mann-Whitney rank test: P = 0.0002, ***). Sample size calculations revealed that 6 mice per group would be required to detect a 50% difference in STiCSS score with a power of 0.8. Finally, the STiCSS was demonstrated to reliably quantify soft tissue calcification [dystrophic calcification and heterotopic ossification] by radiographic analysis, independent of the histopathological state of the mineralization. Radiographic analysis can discriminate muscle injury-induced soft tissue calcification from adjacent bone and follow its clinical course over time without requiring the sacrifice of the animal. While the STiCSS cannot identify the specific type of soft tissue calcification present, it is still a useful and valid method by which to quantify the degree of soft tissue calcification. This methodology allows for longitudinal measurements of soft tissue calcification in a single animal, which is relatively less expensive, less time-consuming, and exposes the animal to less radiation than in vivo μCT. Therefore, this high-throughput, longitudinal analytic method for quantifying soft tissue calcification is a viable alternative for the study of soft tissue calcification.

  1. Validation of a Radiography-Based Quantification Designed to Longitudinally Monitor Soft Tissue Calcification in Skeletal Muscle

    PubMed Central

    Moore, Stephanie N.; Hawley, Gregory D.; Smith, Emily N.; Mignemi, Nicholas A.; Ihejirika, Rivka C.; Yuasa, Masato; Cates, Justin M. M.; Liu, Xulei; Schoenecker, Jonathan G.

    2016-01-01

    Introduction Soft tissue calcification, including both dystrophic calcification and heterotopic ossification, may occur following injury. These lesions have variable fates as they are either resorbed or persist. Persistent soft tissue calcification may result in chronic inflammation and/or loss of function of that soft tissue. The molecular mechanisms that result in the development and maturation of calcifications are uncertain. As a result, directed therapies that prevent or resorb soft tissue calcifications remain largely unsuccessful. Animal models of post-traumatic soft tissue calcification that allow for cost-effective, serial analysis of an individual animal over time are necessary to derive and test novel therapies. We have determined that a cardiotoxin-induced injury of the muscles in the posterior compartment of the lower extremity represents a useful model in which soft tissue calcification develops remote from adjacent bones, thereby allowing for serial analysis by plain radiography. The purpose of the study was to design and validate a method for quantifying soft tissue calcifications in mice longitudinally using plain radiographic techniques and an ordinal scoring system. Methods Muscle injury was induced by injecting cardiotoxin into the posterior compartment of the lower extremity in mice susceptible to developing soft tissue calcification. Seven days following injury, radiographs were obtained under anesthesia. Multiple researchers applied methods designed to standardize post-image processing of digital radiographs (N = 4) and quantify soft tissue calcification (N = 6) in these images using an ordinal scoring system. Inter- and intra-observer agreement for both post-image processing and the scoring system used was assessed using weighted kappa statistics. Soft tissue calcification quantifications by the ordinal scale were compared to mineral volume measurements (threshold 450.7mgHA/cm3) determined by μCT. Finally, sample-size calculations necessary to discriminate between a 25%, 50%, 75%, and 100% difference in STiCSS score 7 days following burn/CTX induced muscle injury were determined. Results Precision analysis demonstrated substantial to good agreement for both post-image processing (κ = 0.73 to 0.90) and scoring (κ = 0.88 to 0.93), with low inter- and intra-observer variability. Additionally, there was a strong correlation in quantification of soft tissue calcification between the ordinal system and by mineral volume quantification by μCT (Spearman r = 0.83 to 0.89). The ordinal scoring system reliably quantified soft tissue calcification in a burn/CTX-induced soft tissue calcification model compared to non-injured controls (Mann-Whitney rank test: P = 0.0002, ***). Sample size calculations revealed that 6 mice per group would be required to detect a 50% difference in STiCSS score with a power of 0.8. Finally, the STiCSS was demonstrated to reliably quantify soft tissue calcification [dystrophic calcification and heterotopic ossification] by radiographic analysis, independent of the histopathological state of the mineralization. Conclusions Radiographic analysis can discriminate muscle injury-induced soft tissue calcification from adjacent bone and follow its clinical course over time without requiring the sacrifice of the animal. While the STiCSS cannot identify the specific type of soft tissue calcification present, it is still a useful and valid method by which to quantify the degree of soft tissue calcification. This methodology allows for longitudinal measurements of soft tissue calcification in a single animal, which is relatively less expensive, less time-consuming, and exposes the animal to less radiation than in vivo μCT. Therefore, this high-throughput, longitudinal analytic method for quantifying soft tissue calcification is a viable alternative for the study of soft tissue calcification. PMID:27438007

  2. Adhesive Properties of Polyacrylate Gels

    NASA Astrophysics Data System (ADS)

    Flanigan, Cynthia; Shull, Kenneth

    1998-03-01

    Soft, low-modulus gels provide an interesting opportunity to examine small adhesive interactions between two bodies in contact. As shown through dynamic rheological studies, our materials undergo a rapid gelation as they are cooled from a viscous liquid at elevated temperatures to a soft, elastic solid at room temperature. At low temperatures, the gels exhibit a linearly elastic response and display moduli close to 100Pa, thereby forming materials with great potential for quantifying weak adhesive interactions with a variety of bodies ranging from polymer surfaces to biological entities. Our current studies focus on investigating interfacial effects by performing axisymmetric adhesion tests with a model polyacrylate gel formed by diluting the copolymer poly(methyl methacrylate)-poly(n-butyl acrylate)-poly(methyl methacrylate) to a 5-15 percent solution in 2-ethyl hexanol, a selective solvent for the midblock. We have explored two different experimental geometries including a hemispherical rigid indenter of glass pressed into a gel layer of varying thicknesses, and a soft, gel cap in contact with a rigid polymer surface. By simultaneously measuring the applied load, displacement between the two bodies, and contact area during loading cycles, we are able to employ a linearly elastic fracture mechanics analysis to obtain estimates of the gel's modulus over a range of polymer concentrations, and G, the energy release rate.

  3. Tissue adhesives for closure of surgical incisions.

    PubMed

    Coulthard, P; Worthington, H; Esposito, M; Elst, M; Waes, O J F

    2004-01-01

    Sutures, staples and adhesive tapes are the traditional methods of wound closure, whilst tissue adhesives have entered clinical practice more recently. Closure of wounds with sutures enables meticulous closure, but sutures may induce tissue reactivity and they usually require removal. Tissue adhesives offer the advantages there are no sutures to remove later for the patient and no risk of needlestick injury to the surgeon. Tissue adhesives have been used primarily in emergency rooms but this review looks at the use of tissue adhesives in the operating room where surgeons are increasingly using these for the closure of surgical skin incisions. To determine the relative effects of various tissue adhesives and conventional skin closure techniques on the healing of surgical wounds. The Cochrane Wounds Group Specialised Trials Register, The Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE and EMBASE were searched. Bibliographies of review articles were checked for studies outside the handsearched journals and wound care product manufacturers were contacted. Randomised controlled clinical trials only. Screening of eligible studies and data extraction was conducted independently and in triplicate whilst assessment of the methodological quality of the trials was conducted independently and in duplicate. Results were expressed as random effect models using weighted mean differences for continuous outcomes and relative risk with 95% confidence intervals for dichotomous outcomes. Heterogeneity was investigated including both clinical and methodological factors. Eight RCTs were included (630 patients). No statistically significant differences were found between various tissue adhesives and sutures (8 trials) for dehiscence, infection, satisfaction with cosmetic appearance when assessed by patients' or surgeons' general satisfaction. Nor were differences found between a tissue adhesive and tapes (2 trials) for infection, patients' assessment of cosmetic appearance, patient satisfaction or surgeon satisfaction. However a statistically significant difference was found for surgeons' assessment of cosmetic appearance with mean difference 13 (95%CI 5 to 21), the higher mean rating for the tissue adhesive group. Surgeons may consider the use of tissue adhesives as an alternative to sutures or adhesive tape for the closure of incisions in the operating room. There is a need for trials in all areas but in particular to include patients that require incision closure in areas of high tension and patients of general health that may impair wound healing.

  4. Injectable Citrate-Based Mussel-Inspired Tissue Bioadhesives With High Wet Strength for Sutureless Wound Closure

    PubMed Central

    Mehdizadeh, M. Reza; Weng, Hong; Gyawali, Dipendra; Tang, Liping; Yang, Jian

    2012-01-01

    The existing surgical adhesives are not ideal for wet tissue adhesion required in many surgeries such as those for internal organs. Developing surgical adhesives with strong wet tissue adhesion, controlled degradability and mechanical properties, and excellent biocompatibility has been a significant challenge. Herein, learning from nature, we report a one-step synthesis of a family of injectable citrate-based mussel-inspired bioadhesives (iCMBAs) for surgical use. Within the formulations investigated, iCMBAs showed 2.5–8.0 folds stronger wet tissue adhesion strength over the clinically used fibrin glue, demonstrated controlled degradability and tissue-like elastomeric mechanical properties, and exhibited excellent cyto/tissue-compatibility both in vitro and in vivo. iCMBAs were able to stop bleeding instantly and suturelessly, and close wounds (2 cm long × 0.5 cm deep) created on the back of Sprague-Dawley rats, which is impossible when using existing gold standard, fibrin glue, due to its weak wet tissue adhesion strength. Equally important, the new bioadhesives facilitate wound healing, and are completely degraded and absorbed without eliciting significant inflammatory response. Our results support that iCMBA technology is highly translational and could have broad impact on surgeries where surgical tissue adhesives, sealants, and hemostatic agents are used. PMID:22902057

  5. Advances in biomaterials for preventing tissue adhesion.

    PubMed

    Wu, Wei; Cheng, Ruoyu; das Neves, José; Tang, Jincheng; Xiao, Junyuan; Ni, Qing; Liu, Xinnong; Pan, Guoqing; Li, Dechun; Cui, Wenguo; Sarmento, Bruno

    2017-09-10

    Adhesion is one of the most common postsurgical complications, occurring simultaneously as the damaged tissue heals. Accompanied by symptoms such as inflammation, pain and even dyskinesia in particular circumstances, tissue adhesion has substantially compromised the quality of life of patients. Instead of passive treatment, which involves high cost and prolonged hospital stay, active intervention to prevent the adhesion from happening has been accepted as the optimized strategy against this complication. Herein, this paper will cover not only the mechanism of adhesion forming, but also the biomaterials and medicines used in its prevention. Apart from acting as a direct barrier, biomaterials also show promising anti-adhesive bioactivity though their intrinsic physical and chemical are still not completely unveiled. Considering the diversity of human tissue organization, it is imperative that various biomaterials in combination with specific medicine could be tuned to fit the microenvironment of targeted tissues. With the illustration of different adhesion mechanism and solutions, we hope this review can become a beacon and further inspires the development of anti-adhesion biomedicines. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Exploring the potential of polyurethane-based soft foam as cell-free scaffold for soft tissue regeneration.

    PubMed

    Gerges, Irini; Tamplenizza, Margherita; Martello, Federico; Recordati, Camilla; Martelli, Cristina; Ottobrini, Luisa; Tamplenizza, Mariacaterina; Guelcher, Scott A; Tocchio, Alessandro; Lenardi, Cristina

    2018-06-01

    Reconstructive treatment after trauma and tumor resection would greatly benefit from an effective soft tissue regeneration. The use of cell-free scaffolds for adipose tissue regeneration in vivo is emerging as an attractive alternative to tissue-engineered constructs, since this approach avoids complications due to cell manipulation and lack of synchronous vascularization. In this study, we developed a biodegradable polyurethane-based scaffold for soft tissue regeneration, characterized by an exceptional combination between softness and resilience. Exploring the potential as a cell-free scaffold required profound understanding of the impact of its intrinsic physico-chemical properties on the biological performance in vivo. We investigated the effect of the scaffold's hydrophilic character, degradation kinetics, and internal morphology on (i) the local inflammatory response and activation of MGCs (foreign body response); (ii) its ability to promote rapid vascularisation, cell infiltration and migration through the scaffold over time; and (iii) the grade of maturation of the newly formed tissue into vascularized soft tissue in a murine model. The study revealed that soft tissue regeneration in vivo proceeded by gradual infiltration of undifferentiated mesenchymal cells though the periphery toward the center of the scaffold, where the rapid formation of a functional and well-formed vascular network supported cell viability overtime. Exploring the potential of polyurethane-based soft foam as cell-free scaffold for soft tissue regeneration. In this work, we address the unmet need for synthetic functional soft tissue substitutes that provide adequate biological and mechanical support to soft tissue. We developed a series of flexible cross-linked polyurethane copolymer scaffolds with remarkable fatigue-resistance and tunable physico-chemical properties for soft tissue regeneration in vivo. Accordingly, we could extend the potential of this class of biomaterials, which was so far confined for bone and osteochondral tissue regeneration, to other types of connective tissue. Copyright © 2018 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  7. Combination Chemotherapy in Treating Patients With Previously Untreated Rhabdomyosarcoma

    ClinicalTrials.gov

    2013-06-13

    Adult Malignant Mesenchymoma; Adult Rhabdomyosarcoma; Alveolar Childhood Rhabdomyosarcoma; Childhood Malignant Mesenchymoma; Embryonal Childhood Rhabdomyosarcoma; Embryonal-botryoid Childhood Rhabdomyosarcoma; Nonmetastatic Childhood Soft Tissue Sarcoma; Previously Untreated Childhood Rhabdomyosarcoma; Stage I Adult Soft Tissue Sarcoma; Stage II Adult Soft Tissue Sarcoma; Stage III Adult Soft Tissue Sarcoma

  8. Dimensional soft tissue changes following soft tissue grafting in conjunction with implant placement or around present dental implants: a systematic review.

    PubMed

    Poskevicius, Lukas; Sidlauskas, Antanas; Galindo-Moreno, Pablo; Juodzbalys, Gintaras

    2017-01-01

    To systematically review changes in mucosal soft tissue thickness and keratinised mucosa width after soft tissue grafting around dental implants. An electronic literature search was conducted of the MEDLINE database published between 2009 and 2014. Sequential screenings at the title, abstract, and full-text levels were performed. Clinical human studies in the English language that had reported changes in soft tissue thickness or keratinised mucosa width after soft tissue grafting at implant placement or around a present implant at 6-month follow-up or longer were included. The search resulted in fourteen articles meeting the inclusion criteria: Six of them reported connective tissue grafting around present dental implants, compared to eight at the time of implant placement. Better long-term soft tissue thickness outcomes were reported for soft tissue augmentation around dental implants (0.8-1.4 mm), compared with augmentation at implant placement (-0.25-1.43 mm). Both techniques were effective in increasing keratinised tissue width: at implant placement (2.5 mm) or around present dental implants (2.33-2.57 mm). The present systematic review discovered that connective tissue grafts enhanced keratinised mucosa width and soft tissue thickness for an observation period of up to 48 months. However, some shrinkage may occur, resulting in decreases in soft tissue, mostly for the first three months. Further investigations using accurate evaluation methods need to be done to evaluate the appropriate time for grafting. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Soft-tissue tension total knee arthroplasty.

    PubMed

    Asano, Hiroshi; Hoshino, Akiho; Wilton, Tim J

    2004-08-01

    It is far from clear how best to define the proper strength of soft-tissue tensioning in total knee arthroplasty (TKA). We attached a torque driver to the Monogram balancer/tensor device and measured soft-tissue tension in full extension and 90 degrees flexion during TKA. In our surgical procedure, when we felt proper soft-tissue tension was being applied, the mean distraction force was noted to be 126N in extension and 121N in flexion. There was no significant correlation between soft-tissue tension and the postoperative flexion angle finally achieved. To the best of our knowledge, this is the first study to assess the actual distraction forces in relation to soft-tissue tension in TKA. Further study may reveal the most appropriate forces to achieve proper soft-tissue tension in the wide variety of circumstances presenting at knee arthroplasty.

  10. Tissue adhesives for simple traumatic lacerations.

    PubMed

    Beam, Joel W

    2008-01-01

    Farion K, Osmond MH, Hartling L, et al. Tissue adhesives for traumatic lacerations in children and adults. Cochrane Database Syst Rev. 2001(4);CD003326. What is the clinical evidence base for tissue adhesives in the management of simple traumatic lacerations? Studies were identified by searches of the following databases: Cochrane Wounds Group Specialized Trials Register (September 2003), Cochrane Central Register of Controlled Trials (CENTRAL) (CDROM 2003, issue 3), MEDLINE (1966 to September 2003, week 1), EMBASE (1988 to 2003, week 36), Web of Science Science Citation Index (1975 to September 13, 2003) and various clinical trials registers (September 2003). Investigators and product manufacturers were contacted to identify additional eligible studies. The search terms included wounds and injuries, laceration, face injury, nose injury, tissue adhesives, and acrylates. Each study fulfilled the following criteria: (1) The study was a randomized controlled trial that compared tissue adhesives with standard wound closure (SWC) (sutures, staples, adhesive strips) or tissue adhesive with tissue adhesive. (2) The wounds were acute, linear lacerations less than 12 hours old, resulting from blunt or sharp trauma. (3) The wound length, width, and depth allowed for approximation of the edges with minimal tension after deep sutures were placed, if required. Studies were included with no language or publication status restriction, with participants of any age recruited in an emergency department, outpatient clinic, walk-in clinic, or other primary care setting. Studies were excluded if the wounds were stellate lacerations, puncture wounds, mammalian bites, infected, heavily contaminated or devitalized, crossing joints or mucocutaneous junctions, in hair-bearing areas, or in patients with keloid formation or chronic illness. The characteristics of the study and participants, interventions, outcome measures, and findings were extracted by one author and verified by a second using a standard form. The primary measure was cosmetic outcome. Secondary measures were pain with the procedure, time to complete the procedure, and complications (erythema, infection, discharge, need for delayed closure, and dehiscence). Studies were divided into 2 groups as follows: group 1, comparisons among tissue adhesives with SWC, and group 2, comparisons among different tissue adhesives. All eligible studies were assessed for methodologic quality independently by 2 investigators using the Jadad Scale, which evaluates randomization, double blinding, withdrawals, and dropouts and is scored on a 5-point (maximum) scale. The data from the tissue adhesive and SWC studies were pooled and analyzed with a random-effects model. The I (2) statistic was used to determine heterogeneity among the studies. chi (2) analysis was performed to compare participant age, wound location, and type of tissue adhesive among the studies. The data from the studies comparing tissue adhesives were pooled and analyzed using a fixed-effects model. The search criteria identified 39 eligible studies, of which 11 met the inclusion criteria. In 10 studies, a tissue adhesive was compared with SWC. Five groups used butylcyanoacrylate, and 5 used octylcyanoacrylate. For SWC, 6 groups used sutures, 2 used adhesive strips, and 2 used a combination of methods, although most used sutures. Six studies were limited to pediatric patients and 2 to adult patients; 2 included patients of any age. Wounds were limited to facial lacerations in 2 pediatric studies and 1 group with patients of any age. Lacerations requiring deep sutures were excluded in 4 studies. One group compared tissue adhesives (butylcyanoacrylate and octylcyanoacrylate) among pediatric patients with facial lacerations not requiring deep sutures. In the 11 included studies, authors of 9 randomized and evaluated 1 laceration per patient, whereas 2 groups included patients with more than 1 laceration. In 1 group, each laceration was independently randomized and evaluated, and the other group randomized the patient and assigned all lacerations to a treatment group (tissue adhesive with SWC or tissue adhesive with tissue adhesive). The sample sizes ranged between 60 and 163 lacerations, and all 11 studies were performed in emergency departments. The primary measure in all included studies was cosmetic outcome. The majority of groups used the Cosmetic Visual Analogue Scale, the Wound Evaluation Score, or a combination of these measures. Three groups measured cosmetic outcome with nonvalidated scoring systems. Assessment time periods were grouped and reported at (1) 5 to 14 days, (2) 1 to 3 months, and (3) 9 to 12 months after wound closure. Secondary outcomes were pain (as noted on visual analogue scale) and time to complete the procedure (as mean number of minutes). The 11 studies scored from 1 to 3 on the Jadad Scale. Adequate allocation concealment was reported in only 1 group. Examining cosmetic outcome, 8 groups (565 lacerations) used the Cosmetic Visual Analogue Scale to compare tissue adhesives and SWC. The authors reported no significant differences in scores at the time periods of 5 to 14 days, 1 to 3 months, and 9 to 12 months. A subgroup analysis showed a significant ( P = .005) superiority of butylcyanoacrylate over SWC at 1 to 3 months. Using the Wound Evaluation Score, 4 studies (364 lacerations) compared tissue adhesives with SWC. No significant differences in cosmetic scores were found at 5 to 14 days, 1 to 3 months, or 9 to 12 months. One group (83 lacerations) compared butylcyanoacrylate with octylcyanoacrylate and reported no significant differences in cosmetic scores using the Cosmetic Visual Analogue Scale at 1 to 3 months and the Wound Evaluation Score at 5 to 14 days and 1 to 3 months. Examining secondary outcomes, 6 groups (570 lacerations) compared tissue adhesives with SWC using the visual analogue scale for pain. Scores reported by parents, patients, physicians, and nurses significantly favored tissue adhesives. In 6 studies (584 lacerations), tissue adhesives were significantly favored over SWC in time to complete the procedure. For complication outcomes, 8 groups (727 lacerations) demonstrated significantly fewer incidences of erythema and an increased risk of dehiscence with tissue adhesives compared with SWC. No significant differences were shown for infection, delayed closure, or discharge. Among 83 lacerations, 1 group compared butylcyanoacrylate with octylcyanoacrylate and reported no significant differences in combined patient-reported and parent-reported visual analogue pain scores, time to complete the procedure, dehiscence, or infection. This review provides evidence that tissue adhesives are an option to SWC (sutures, staples, adhesive strips) for the management of simple traumatic lacerations. Overall, no significant differences were found in cosmetic scores at the reported assessment periods between tissue adhesives and SWC. At 1 to 3 months, a subgroup analysis significantly favored butylcyanoacrylate over SWC. Tissue adhesives significantly lowered the time to complete the procedure, levels of pain, and rate of erythema. However, the data revealed a significant increase in the rate of dehiscence with the use of tissue adhesives when compared with SWC. The low methodologic quality of the evidence should be considered in the interpretation of the findings.

  11. Soft Tissue Sarcoma—Patient Version

    Cancer.gov

    Soft tissue sarcoma is a cancer that starts in soft tissues like muscle, tendons, fat, lymph vessels, blood vessels, and nerves. These cancers can develop anywhere in the body but are found mostly in the arms, legs, chest, and abdomen. Start here to find information on soft tissue sarcoma treatment and research.

  12. Combination Chemotherapy and Radiation Therapy in Treating Patients With Newly Diagnosed Rhabdomyosarcoma

    ClinicalTrials.gov

    2017-06-27

    Adult Malignant Mesenchymoma; Adult Rhabdomyosarcoma; Childhood Alveolar Rhabdomyosarcoma; Childhood Botryoid-Type Embryonal Rhabdomyosarcoma; Childhood Embryonal Rhabdomyosarcoma; Childhood Malignant Mesenchymoma; Non-Metastatic Childhood Soft Tissue Sarcoma; Stage I Adult Soft Tissue Sarcoma; Stage II Adult Soft Tissue Sarcoma; Stage III Adult Soft Tissue Sarcoma; Untreated Childhood Rhabdomyosarcoma

  13. Morphological adaptations in breast cancer cells as a function of prolonged passaging on compliant substrates

    PubMed Central

    Syed, Sana; Schober, Joseph; Blanco, Alexandra

    2017-01-01

    Standard tissue culture practices involve propagating cells on tissue culture polystyrene (TCP) dishes, which are flat, 2-dimensional (2D) and orders of magnitude stiffer than most tissues in the body. Such simplified conditions lead to phenotypical cell changes and altered cell behaviors. Hence, much research has been focused on developing novel biomaterials and culture conditions that more closely emulate in vivo cell microenvironments. In particular, biomaterial stiffness has emerged as a key property that greatly affects cell behaviors such as adhesion, morphology, proliferation and motility among others. Here we ask whether cells that have been conditioned to TCP, would still show significant dependence on substrate stiffness if they are first pre-adapted to a more physiologically relevant environment. We used two commonly utilized breast cancer cell lines, namely MDA-MB-231 and MCF-7, and examined the effect of prolonged cell culturing on polyacrylamide substrates of varying compliance. We followed changes in cell adhesion, proliferation, shape factor, spreading area and spreading rate. After pre-adaptation, we noted diminished differences in cell behaviors when comparing between soft (1 kPa) and stiff (103 kPa) gels as well as rigid TCP control. Prolonged culturing of cells on complaint substrates further influenced responses of pre-adapted cells when transferred back to TCP. Our results have implications for the study of stiffness-dependent cell behaviors and indicate that cell pre-adaptation to the substrate needs consideration. PMID:29136040

  14. Fabrication of continuous electrospun filaments with potential for use as medical fibres.

    PubMed

    Mouthuy, Pierre-Alexis; Zargar, Nasim; Hakimi, Osnat; Lostis, Emilie; Carr, Andrew

    2015-05-19

    Soft tissue injuries represent a substantial and growing social and economic burden. Medical fibres are commonly used to repair these injuries during surgery. Patient's outcomes are, however, not promising with around 40% of surgical repairs failing within the first few months after surgery due to poor tissue regeneration. The application of nanofibrous filaments and yarns as medical fibres and scaffolds has been suggested to improve soft tissue regeneration and enhance the quality of the repair. However, due to a lack of robustness and reliability of the current fabrication methods, continuous nanofibrous filaments cannot be manufactured and scaled up in industrial settings and are not currently available for clinical use. We have developed a robust and automated method that enables the manufacture of continuous electrospun filaments and which has the potential to be integrated into existing textile production lines. The technology uses a wire guide to form submicrofibres in a dense, narrow mesh which can be detached as a long and continuous thread. The thread can then be stretched and used to create multifilament yarns which can imitate the hierarchical architecture of tissues such as tendons and ligaments. Electrospun polydioxanone yarns produced by this method showed improved cellular proliferation and adhesion when compared to medical monofilament fibres in current clinical use. In vivo, the electrospun yarns showed a good safety profile with mild foreign body reaction and complete degradation within 5 months after implantation. These results suggest that this filament collection method has the potential to become a useful platform for the fabrication of future medical textiles.

  15. Molecular energy dissipation in nanoscale networks of dentin matrix protein 1 is strongly dependent on ion valence

    NASA Astrophysics Data System (ADS)

    Adams, J.; Fantner, G. E.; Fisher, L. W.; Hansma, P. K.

    2008-09-01

    The fracture resistance of biomineralized tissues such as bone, dentin, and abalone is greatly enhanced through the nanoscale interactions of stiff inorganic mineral components with soft organic adhesive components. A proper understanding of the interactions that occur within the organic component, and between the organic and inorganic components, is therefore critical for a complete understanding of the mechanics of these tissues. In this paper, we use atomic force microscope (AFM) force spectroscopy and dynamic force spectroscopy to explore the effect of ionic interactions within a nanoscale system consisting of networks of dentin matrix protein 1 (DMP1) (a component of both bone and dentin organic matrix), a mica surface and an AFM tip. We find that DMP1 is capable of dissipating large amounts of energy through an ion-mediated mechanism, and that the effectiveness increases with increasing ion valence.

  16. 3D calcite heterostructures for dynamic and deformable mineralized matrices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yi, Jaeseok; Wang, Yucai; Jiang, Yuanwen

    Scales are rooted in soft tissues, and are regenerated by specialized cells. The realization of dynamic synthetic analogues with inorganic materials has been a significant challenge, because the abiological regeneration sites that could yield deterministic growth behavior are hard to form. Here we overcome this fundamental hurdle by constructing a mutable and deformable array of three-dimensional calcite heterostructures that are partially locked in silicone. Individual calcite crystals exhibit asymmetrical dumbbell shapes and are prepared by a parallel tectonic approach under ambient conditions. Furthermore, the silicone matrix immobilizes the epitaxial nucleation sites through self-templated cavities, which enables symmetry breaking in reactionmore » dynamics and scalable manipulation of the mineral ensembles. With this platform, we devise several mineral-enabled dynamic surfaces and interfaces. For example, we show that the induced growth of minerals yields localized inorganic adhesion for biological tissue and reversible focal encapsulation for sensitive components in flexible electronics.« less

  17. 3D calcite heterostructures for dynamic and deformable mineralized matrices

    DOE PAGES

    Yi, Jaeseok; Wang, Yucai; Jiang, Yuanwen; ...

    2017-09-11

    Scales are rooted in soft tissues, and are regenerated by specialized cells. The realization of dynamic synthetic analogues with inorganic materials has been a significant challenge, because the abiological regeneration sites that could yield deterministic growth behavior are hard to form. Here we overcome this fundamental hurdle by constructing a mutable and deformable array of three-dimensional calcite heterostructures that are partially locked in silicone. Individual calcite crystals exhibit asymmetrical dumbbell shapes and are prepared by a parallel tectonic approach under ambient conditions. Furthermore, the silicone matrix immobilizes the epitaxial nucleation sites through self-templated cavities, which enables symmetry breaking in reactionmore » dynamics and scalable manipulation of the mineral ensembles. With this platform, we devise several mineral-enabled dynamic surfaces and interfaces. For example, we show that the induced growth of minerals yields localized inorganic adhesion for biological tissue and reversible focal encapsulation for sensitive components in flexible electronics.« less

  18. Soft-Tissue Grafting Techniques Associated With Immediate Implant Placement.

    PubMed

    Bishara, Mark; Kurtzman, Gregori M; Khan, Waji; Choukroun, Joseph; Miron, Richard J

    2018-02-01

    Immediate implant placement often presents challenges in terms of predictably obtaining soft-tissue coverage over the implant site. While delayed implant placement offers the ability for soft tissues to grow and invade the extraction socket making their attachment around implants more predictable, immediate implant placement poses a significant risk of bacterial invasion towards the implant surface as a result of insignificant soft-tissue volume. Soft-tissue grafting techniques have often been proposed for use during immediate implant placement to augment soft-tissue deficiencies, including the use of either palatal connective tissue grafts (CTGs) or collagen-derived scaffolds. However, both of these approaches have significant drawbacks in that CTGs are harvested with high patient morbidity and collagen scaffolds remain avascular and acelluar posing a risk of infection/implant contamination. More recently, platelet-rich fibrin (PRF) has been proposed as an economical and biological means to speed soft-tissue wound healing. In combination with immediate implant placement, PRF offers an easily procurable low-cost regenerative modality that offers an efficient way to improve soft-tissue attachment around implants. Furthermore, the supra-physiological concentration of defense-fighting leukocytes in PRF, combined with a dense fibrin meshwork, is known to prevent early bacterial contamination of implant surfaces, and the biological concentrations of autologous growth factors in PRF is known to increase tissue regeneration. This article discusses soft-tissue grafting techniques associated with immediate implant placement, presents several cases demonstrating the use of PRF in routine immediate implant placement, and further discusses the biological and economic advantages of PRF for the management of soft-tissue grafting during immediate implant placement.

  19. Mechanical properties and cytotoxicity of experimental soft lining materials based on urethane acrylate oligomers.

    PubMed

    Kanie, Takahito; Tomita, Koichi; Tokuda, Masayuki; Arikawa, Hiroyuki; Fujii, Koichi; Ban, Seiji

    2009-07-01

    The purpose of this investigation was to determine whether experimental light-curing soft lining materials (ESLMs) based on commercially available urethane acrylate oligomers (UA-160TM, UV-3200B, UV-3500BA, and UV-3700B) are suitable for clinical use by measuring their viscosity, compressive modulus, Shore A hardness, tensile strength, adhesive strength, and cytotoxicity. The viscosities of the four ESLMs at 25 degrees C were 10.5 Pa.s, UV-3500BA; 144.0 Pa.s, UA-160TM; 328.8 Pa.s, UV-3700B; and 1079.7 Pa.s, UV-3200B. Polymerized UV-3700B was very soft, whereas the softness of the other ESLMs was similar to that of conventional soft lining materials. No significant difference in adhesive strength was observed between UV-3500BA and UV-3700B at 1 day and those at 12 months. Cytotoxicity was measured by a MTT-based assay using HeLa S3 and Ca9-22 cells. UV-3200B and UV-3700B oligomers and all four polymerized ESLMs showed cell viability over 95.2% (p < 0.05).

  20. Melorheostosis with recurrent soft-tissue components: a histologically confirmed case.

    PubMed

    Hasegawa, Shoichi; Kanda, Shotaro; Imada, Hiroki; Yamaguchi, Takehiko; Akiyama, Toru

    2017-03-01

    Melorheostosis is a very rare disorder characterized by irregular cortical thickening seen on radiographs. In this paper, we present a case of melorheostosis with microscopically confirmed soft-tissue components. The patient was a 51-year-old man who complained of severe pain in the lateral aspect of his right knee. The excision of an ossified soft-tissue lesion relieved intractable pain that had lasted 20 years. Microscopically, the cortex of the affected fibula was composed of thick compact bone and the soft-tissue component consisted of dense compact bone without endochondral ossification. The presence of soft-tissue osseous nodules around the joints is one of the specific conditions for melorheostosis and should be differentiated from synovial chondromatosis. The ossified soft-tissue lesion in our patient is to our knowledge the first reported case of the histologically confirmed soft-tissue component of melorheostosis, which differs from that of synovial chondromatosis.

  1. Fiber-reinforced scaffolds in soft tissue engineering

    PubMed Central

    Wang, Wei; Fan, Yubo; Wang, Xiumei; Watari, Fumio

    2017-01-01

    Abstract Soft tissue engineering has been developed as a new strategy for repairing damaged or diseased soft tissues and organs to overcome the limitations of current therapies. Since most of soft tissues in the human body are usually supported by collagen fibers to form a three-dimensional microstructure, fiber-reinforced scaffolds have the advantage to mimic the structure, mechanical and biological environment of natural soft tissues, which benefits for their regeneration and remodeling. This article reviews and discusses the latest research advances on design and manufacture of novel fiber-reinforced scaffolds for soft tissue repair and how fiber addition affects their structural characteristics, mechanical strength and biological activities in vitro and in vivo. In general, the concept of fiber-reinforced scaffolds with adjustable microstructures, mechanical properties and degradation rates can provide an effective platform and promising method for developing satisfactory biomechanically functional implantations for soft tissue engineering or regenerative medicine. PMID:28798872

  2. Soft tissue modelling through autowaves for surgery simulation.

    PubMed

    Zhong, Yongmin; Shirinzadeh, Bijan; Alici, Gursel; Smith, Julian

    2006-09-01

    Modelling of soft tissue deformation is of great importance to virtual reality based surgery simulation. This paper presents a new methodology for simulation of soft tissue deformation by drawing an analogy between autowaves and soft tissue deformation. The potential energy stored in a soft tissue as a result of a deformation caused by an external force is propagated among mass points of the soft tissue by non-linear autowaves. The novelty of the methodology is that (i) autowave techniques are established to describe the potential energy distribution of a deformation for extrapolating internal forces, and (ii) non-linear materials are modelled with non-linear autowaves other than geometric non-linearity. Integration with a haptic device has been achieved to simulate soft tissue deformation with force feedback. The proposed methodology not only deals with large-range deformations, but also accommodates isotropic, anisotropic and inhomogeneous materials by simply changing diffusion coefficients.

  3. Effect of fibril shape on adhesive properties

    NASA Astrophysics Data System (ADS)

    Soto, Daniel; Hill, Ginel; Parness, Aaron; Esparza, Noé; Cutkosky, Mark; Kenny, Tom

    2010-08-01

    Research into the gecko's adhesive system revealed a unique architecture for adhesives using tiny hairs. By using a stiff material (β-keratin) to create a highly structured adhesive, the gecko's system demonstrates properties not seen in traditional pressure-sensitive adhesives which use a soft, unstructured planar layer. In contrast to pressure sensitive adhesives, the gecko adhesive displays frictional adhesion, in which increased shear force allows it to withstand higher normal loads. Synthetic fibrillar adhesives have been fabricated but not all demonstrate this frictional adhesion property. Here we report the dual-axis force testing of single silicone rubber pillars from synthetic adhesive arrays. We find that the shape of the adhesive pillar dictates whether frictional adhesion or pressure-sensitive behavior is observed. This work suggests that both types of behavior can be achieved with structures much larger than gecko terminal structures. It also indicates that subtle differences in the shape of these pillars can significantly influence their properties.

  4. Concomitant Correction of a Soft-Tissue Fenestration with Keratinised Tissue Augmentation By Using A Rotated Double-Pedicle Flap During Second-Stage Implant Surgery- A Case Report

    PubMed Central

    Reddy, Aileni Amarender; Kumar, P. Anoop; Sailaja, Sistla; Chakravarthy, Yshs

    2015-01-01

    Soft tissue deficiencies and defects around dental implants have been observed frequently. Soft-tissue defects after implant procedures originate from the process of modelling of periimplant mucosa and often cause aesthetic disharmony, food debris accumulation and soft tissue shrinkage. Periimplant mucogingival surgery focuses on creating an optimum band of keratinized tissue resulting in soft tissue architecture similar to the gingiva around natural teeth. A 23-year-old male reported to the Department of Periodontology with a complaint of gum soreness, foul smell and food accumulation at a site where a 3.75 x 11.5mm implant was placed previously. On clinical examination, fenestration of tissue above the cover screw was observed and there appeared to be a keratinized tissue of 1mm surrounding the implant. The case was managed by use of a rotated double-pedicle flap during second-stage implant surgery to correct the soft-tissue fenestration defect and to obtain a keratinized periimplant soft tissue. A periosteal bed was prepared by giving a horizontal incision at the mucogingival junction to a depth of 4 mm. Two split-thickness keratinized pedicles were dissected from the mesial and distal interproximal tissues near the implant. After rotation, both the pedicles were sutured to each other mid-buccally and the pedicles were rigidly immobilized with sutures. At 1 month, there was a 3mm band of stable and firm keratinized tissue over the underlying tissues. The procedure resulted in an aesthetic improvement due to enhanced soft tissue architecture and optimum integration between the peri-implant soft tissue and the final prosthesis. PMID:26816998

  5. Prevalence of Soft Tissue Calcifications in CBCT Images of Mandibular Region.

    PubMed

    Khojastepour, Leila; Haghnegahdar, Abdolaziz; Sayar, Hamed

    2017-06-01

    Most of the soft tissue calcifications within the head and neck region might not be accompanied by clinical symptoms but may indicate some pathological conditions. The aim of this research was to determine the prevalence of soft tissue calcifications in cone beam computed tomography (CBCT) images of mandibular region. In this cross sectional study the CBCT images of 602 patients including 294 men and 308 women with mean age 41.38±15.18 years were evaluated regarding the presence, anatomical location; type (single or multiple) and size of soft tissue calcification in mandibular region. All CBCT images were acquired by NewTom VGi scanner. Odds ratio and chi-square tests were used for data analysis and p < 0.05 was considered to be statistically significant. 156 out of 602 patients had at least one soft tissue calcification in their mandibular region (25.9%. of studied population with mean age 51.7±18.03 years). Men showed significantly higher rate of soft tissue calcification than women (30.3% vs. 21.8%). Soft tissue calcification was predominantly seen at posterior region of the mandible (88%) and most of them were single (60.7%). The prevalence of soft tissue calcification increased with age. Most of the detected soft tissue calcifications were smaller than 3mm (90%). Soft tissue calcifications in mandibular area were a relatively common finding especially in posterior region and more likely to happen in men and in older age group.

  6. [Study of susceptibility weighted imaging on MR and pathologic findings to distinguish benign or malignant soft tissue tumor].

    PubMed

    Liu, J; Chen, Y; Bao, X M; Ling, X L; Ding, J P; Zhang, Z K

    2017-05-23

    Objective: To explore the diagnostic performance of susceptibility weighted imaging (SWI)in distinguishing benign or malignant soft tissue tumor, and to study pathological observation. Methods: Sixty-eight patients with soft tissue tumor, who received no previous treatment or invasive examination, received routine preoperative MRI examination and SWI scanning. The graduation and distribution of intratumoral susceptibility signal intensity(ITSS) and proportion of tumor volume were observed.The pathological results were also included for comparative analysis. Results: Fourty of 68 patients were benign and 28 were malignant. 72.5% (29/40) patients with benign soft tissue tumors were ITSS grade 1 and ITSS grade 3 (hemangioma). 89.3%(25/28) patients with malignant soft tissue tumors were ITSS grade 2 and ITSS grade 3. The difference was statistically significant ( P <0.01). The distribution of ITSS in patients with benign soft tissue tumors was dominated by peripheral distribution and diffuse distribution (hemangioma), accounting for 90.0% (36/40). The distribution of ITSS in patients with malignant soft tissue tumors mainly distributed in the central region, accounting for 78.6% (22 /28). The difference was statistically significant ( P <0.01). The proportion of tumor volume occupied by ITSS in benign soft tissue tumors was <1/3 and> 2/3 (hemangioma), accounting for 90.0% (36/40). The volume of malignant soft tissue tumors were predominantly <1/3 , accounting for 82.1% (23/28). The difference was statistically significant ( P <0.01). Conclusion: SWI is sensitive in displaying the vein and blood metabolites in soft tissue lesions, which is helpful for the differential diagnosis of benign and malignant tumors in soft tissue.

  7. The efficacy of the modified classification system of soft tissue injury in extension injury of the lower cervical spine.

    PubMed

    Song, Kyung-Jin; Kim, Gyu-Hyung; Lee, Kwang-Bok

    2008-07-01

    To classify comprehensively the severity of soft tissue injury for extension injuries of the lower cervical spine by magnetic resonance imaging (MRI). To investigate severity of extension injuries using a modified classification system for soft tissue injury by MRI, and to determine the possibility of predicting cord injury by determining the severity of soft tissue injury. It is difficult to diagnose extension injuries by plain radiography and computed tomography. MRI is considered to be the best method of diagnosing soft tissue injuries. The authors examined whether an MRI based diagnostic standard could be devised for extension injuries of the cervical spine. MRI was performed before surgery in 81 patients that had experienced a distractive-extension injury during the past 5 years. Severities of soft tissue injury were subdivided into 5 stages. The retropharyngeal space and the retrotracheal space were measured, and their correlations with the severity of soft tissue injury were examined, as was the relation between canal stenosis and cord injury. Cord injury developed in injuries greater than Grade III (according to our devised system) accompanied by posterior longitudinal ligament rupture (P < 0.01). As the severity of soft tissue injury increased, the cord signal change increased (P < 0.01), the retropharyngeal space and the retrotracheal space increased, and swelling severity in each stage were statistically significant (P < 0.01). In canal stenosis patients, soft tissue damage and cord injury were not found to be associated (P = 0.45). In cases of distractive-extension injury, levels of soft tissue injury were determined accurately by MRI. Moreover, the severity of soft tissue injury was found to be closely associated with the development of cord injury.

  8. A study of cephalometric soft tissue profile among adolescents from the three West African countries of Nigeria, Ghana and Senegal.

    PubMed

    Fadeju, A D; Otuyemi, O D; Ngom, P I; Newman-Nartey, M

    2013-03-01

    Since the introduction of cephalometry, numerous studies have established normal values for Caucasian populations. In Africa, most investigations have established norms and ethnic variations associated with the skeletal pattern. To date, there has been no study comparing soft tissue patterns among adolescents in the West African sub-region. The objective of this investigation was to determine and compare soft tissue patterns among 12- to 16-year-old Nigerian, Ghanaian and Senegalese adolescents, establish any gender dimorphism and compare them with published Caucasian norms. Lateral cephalometric radiographs of adolescents with a normal incisor relationship aged between 12 and 16 years from Nigeria, Ghana, and Senegal were taken under standardized conditions and traced to determine soft tissue patterns. Data obtained were subjected to statistical analysis. The total sample consisted of 165 females and 135 males with a mean age of 13·96 (1·58) years. A number of soft tissue parameters showed significant differences (P<0·05). These included comparison between males and females, and Nigerian, Ghanaian and Senegalese, including lip separation, upper lip length, upper lip exposure, Li-esthetic line, lower lip-NP, nasal tip angle, N-Pr-Pg, Pg-Ls, B-N pogonion and pogonion-mandibular angle. Differences also existed between these West African soft tissue values and published Caucasian norms, including nasolabial angle, mentolabial angle, nasal depth, nose tip, total soft tissue facial convexity and nasal depth angle. The comparative analysis of soft tissue patterns among 12- to 16-year-old adolescents from Nigeria, Ghana and Senegal demonstrated statistically significant differences in soft tissue value between these West African adolescents and published Caucasian soft tissue norms. This study provides useful data in relation to soft tissue parameters for subjects originating from the West African sub-region.

  9. Characterization of silver nanoparticle-infused tissue adhesive for ophthalmic use.

    PubMed

    Yee, William; Selvaduray, Guna; Hawkins, Benjamin

    2015-03-01

    In this work, we demonstrate the successful enhancement of breaking strength, adhesive strength, and antibacterial efficacy of ophthalmic tissue adhesive (2-octyl cyanoacrylate) by doping with silver nanoparticles, and investigate the effects of nanoparticle size and concentration. Recent work has shown that silver nanoparticles are a viable antibacterial additive to many compounds, but their efficacy in tissue adhesives was heretofore untested. Our results indicate that doping the adhesive with silver nanoparticles reduced bacterial growth by an order of magnitude or more; nanoparticle size and concentration had minimal influence in the range tested. Tensile breaking strength of polymerized adhesive samples and adhesive strength between a T-shaped support and excised porcine sclera were measured using a universal testing machine according to ASTM (formerly American Society for Testing and Materials) standard techniques. Both tests showed significant improvement with the addition of silver nanoparticles. The enhanced mechanical strength and antibacterial efficacy of the doped adhesive supports the use of tissue adhesives as a viable supplement or alternative to sutures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Towards an in vitro model mimicking the foreign body response: tailoring the surface properties of biomaterials to modulate extracellular matrix.

    PubMed

    Damanik, Febriyani F R; Rothuizen, Tonia C; van Blitterswijk, Clemens; Rotmans, Joris I; Moroni, Lorenzo

    2014-09-19

    Despite various studies to minimize host reaction following a biomaterial implantation, an appealing strategy in regenerative medicine is to actively use such an immune response to trigger and control tissue regeneration. We have developed an in vitro model to modulate the host response by tuning biomaterials' surface properties through surface modifications techniques as a new strategy for tissue regeneration applications. Results showed tunable surface topography, roughness, wettability, and chemistry by varying treatment type and exposure, allowing for the first time to correlate the effect of these surface properties on cell attachment, morphology, strength and proliferation, as well as proinflammatory (IL-1β, IL-6) and antiinflammatory cytokines (TGF-β1, IL-10) secreted in medium, and protein expression of collagen and elastin. Surface microstructuring, derived from chloroform partial etching, increased surface roughness and oxygen content. This resulted in enhanced cell adhesion, strength and proliferation as well as a balance of soluble factors for optimum collagen and elastin synthesis for tissue regeneration. By linking surface parameters to cell activity, we could determine the fate of the regenerated tissue to create successful soft tissue-engineered replacement.

  11. Towards an in vitro model mimicking the foreign body response: tailoring the surface properties of biomaterials to modulate extracellular matrix

    NASA Astrophysics Data System (ADS)

    Damanik, Febriyani F. R.; Rothuizen, Tonia C.; van Blitterswijk, Clemens; Rotmans, Joris I.; Moroni, Lorenzo

    2014-09-01

    Despite various studies to minimize host reaction following a biomaterial implantation, an appealing strategy in regenerative medicine is to actively use such an immune response to trigger and control tissue regeneration. We have developed an in vitro model to modulate the host response by tuning biomaterials' surface properties through surface modifications techniques as a new strategy for tissue regeneration applications. Results showed tunable surface topography, roughness, wettability, and chemistry by varying treatment type and exposure, allowing for the first time to correlate the effect of these surface properties on cell attachment, morphology, strength and proliferation, as well as proinflammatory (IL-1β, IL-6) and antiflammatory cytokines (TGF-β1, IL-10) secreted in medium, and protein expression of collagen and elastin. Surface microstructuring, derived from chloroform partial etching, increased surface roughness and oxygen content. This resulted in enhanced cell adhesion, strength and proliferation as well as a balance of soluble factors for optimum collagen and elastin synthesis for tissue regeneration. By linking surface parameters to cell activity, we could determine the fate of the regenerated tissue to create successful soft tissue-engineered replacement.

  12. Single-stage Reconstruction of Elbow Flexion Associated with Massive Soft-Tissue Defect Using the Latissimus Dorsi Muscle Bipolar Rotational Transfer

    PubMed Central

    Cuéllar, Vanessa G.; Ghiassi, Alidad; Sharpe, Frances

    2016-01-01

    Introduction: In the upper extremity, the latissimus dorsi muscle can be used as an ipsilateral rotational muscle flap for soft-tissue coverage or functional reconstruction of arm and elbow. Patients who have both major soft-tissue loss and functional deficits can be successfully treated with a single-stage functional latissimus dorsi rotational muscle transfer that provides simultaneous soft-tissue coverage and functional reconstruction. Methods: Our data base was queried for all patients undergoing a rotational latissimus dorsi muscle transfer for simultaneous soft-tissue coverage and functional reconstruction of elbow flexion. Four patients were identified. A chart review documented the mechanism of injury, associated injuries, soft-tissue defect size, number of surgical procedures, length of follow-up, last elbow range of motion, and flexion strength. Results: Four patients with loss of elbow flexion due to traumatic loss of the anterior compartment muscles and the overlying soft tissue underwent simultaneous soft-tissue coverage and elbow flexorplasty using the ipsilateral latissimus dorsi as a bipolar muscle rotational tissue transfer. All flaps survived and had a recovery of Medical Research Council Grade 4/5 elbow flexion strength. No additional procedures were required for elbow flexion. The surgical technique is described and supplemented with surgical technique video and patient outcome. Conclusions: This patient series augments the data provided in other series supporting the safety and efficacy of this procedure which provides both soft-tissue coverage and functional restoration of elbow flexion as a single-stage procedure in the setting of massive traumatic soft-tissue loss of the arm. PMID:27757363

  13. Single-stage Reconstruction of Elbow Flexion Associated with Massive Soft-Tissue Defect Using the Latissimus Dorsi Muscle Bipolar Rotational Transfer.

    PubMed

    Stevanovic, Milan V; Cuéllar, Vanessa G; Ghiassi, Alidad; Sharpe, Frances

    2016-09-01

    In the upper extremity, the latissimus dorsi muscle can be used as an ipsilateral rotational muscle flap for soft-tissue coverage or functional reconstruction of arm and elbow. Patients who have both major soft-tissue loss and functional deficits can be successfully treated with a single-stage functional latissimus dorsi rotational muscle transfer that provides simultaneous soft-tissue coverage and functional reconstruction. Our data base was queried for all patients undergoing a rotational latissimus dorsi muscle transfer for simultaneous soft-tissue coverage and functional reconstruction of elbow flexion. Four patients were identified. A chart review documented the mechanism of injury, associated injuries, soft-tissue defect size, number of surgical procedures, length of follow-up, last elbow range of motion, and flexion strength. Four patients with loss of elbow flexion due to traumatic loss of the anterior compartment muscles and the overlying soft tissue underwent simultaneous soft-tissue coverage and elbow flexorplasty using the ipsilateral latissimus dorsi as a bipolar muscle rotational tissue transfer. All flaps survived and had a recovery of Medical Research Council Grade 4/5 elbow flexion strength. No additional procedures were required for elbow flexion. The surgical technique is described and supplemented with surgical technique video and patient outcome. This patient series augments the data provided in other series supporting the safety and efficacy of this procedure which provides both soft-tissue coverage and functional restoration of elbow flexion as a single-stage procedure in the setting of massive traumatic soft-tissue loss of the arm.

  14. New scale-down methodology from commercial to lab scale to optimize plant-derived soft gel capsule formulations on a commercial scale.

    PubMed

    Oishi, Sana; Kimura, Shin-Ichiro; Noguchi, Shuji; Kondo, Mio; Kondo, Yosuke; Shimokawa, Yoshiyuki; Iwao, Yasunori; Itai, Shigeru

    2018-01-15

    A new scale-down methodology from commercial rotary die scale to laboratory scale was developed to optimize a plant-derived soft gel capsule formulation and eventually manufacture superior soft gel capsules on a commercial scale, in order to reduce the time and cost for formulation development. Animal-derived and plant-derived soft gel film sheets were prepared using an applicator on a laboratory scale and their physicochemical properties, such as tensile strength, Young's modulus, and adhesive strength, were evaluated. The tensile strength of the animal-derived and plant-derived soft gel film sheets was 11.7 MPa and 4.41 MPa, respectively. The Young's modulus of the animal-derived and plant-derived soft gel film sheets was 169 MPa and 17.8 MPa, respectively, and both sheets showed a similar adhesion strength of approximately 4.5-10 MPa. Using a D-optimal mixture design, plant-derived soft gel film sheets were prepared and optimized by varying their composition, including variations in the mass of κ-carrageenan, ι-carrageenan, oxidized starch and heat-treated starch. The physicochemical properties of the sheets were evaluated to determine the optimal formulation. Finally, plant-derived soft gel capsules were manufactured using the rotary die method and the prepared soft gel capsules showed equivalent or superior physical properties compared with pre-existing soft gel capsules. Therefore, we successfully developed a new scale-down methodology to optimize the formulation of plant-derived soft gel capsules on a commercial scale. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Therapeutically Targeting the Inflammasome Product in a Chimeric Model of Endometriosis-Related Surgical Adhesions.

    PubMed

    Stocks, Meredith M; Crispens, Marta A; Ding, Tianbing; Mokshagundam, Shilpa; Bruner-Tran, Kaylon L; Osteen, Kevin G

    2017-08-01

    Development of adhesions commonly occurs in association with surgery for endometriosis. Even in the absence of surgery, women with endometriosis appear to be at an enhanced risk of developing adhesions. In the current study, we utilized a chimeric mouse model of experimental endometriosis in order to examine the role of inflammasome activation in the development of postsurgical adhesions. Mice were randomized to receive peritoneal injections of human endometrial tissue fragments or endometrial tissue conditioned media (CM) from women with or without endometriosis 16 hours after ovariectomy and placement of an estradiol-releasing silastic capsule. A subset of mice receiving CM was also treated with interleukin (IL) 1 receptor antagonist (IL-1ra). Our studies demonstrate that peritoneal injection of endometrial tissue fragments near the time of surgery resulted in extensive adhesive disease regardless of tissue origin. However, adhesion scores were significantly higher in mice receiving CM from tissues acquired from patients with endometriosis compared to control tissue CM ( P = .0001). Cytokine bead array analysis of endometrial CM revealed enhanced expression of IL-1β from patients with endometriosis compared to controls ( P < .01). Finally, the ability of human tissue CM to promote adhesive disease was dramatically reduced in mice cotreated with IL-1ra ( P < .0001). Our data implicate enhanced expression of IL-1β in women with endometriosis as a potential causal factor in their increased susceptibility of developing postsurgical adhesions. Thus, targeting inflammasome activation may be an effective strategy for the prevention of surgical adhesions in patients with endometriosis.

  16. Effect of tissue composition on dose distribution in brachytherapy with various photon emitting sources

    PubMed Central

    Ghorbani, Mahdi; Salahshour, Fateme; Haghparast, Abbas; Knaup, Courtney

    2014-01-01

    Purpose The aim of this study is to compare the dose in various soft tissues in brachytherapy with photon emitting sources. Material and methods 103Pd, 125I, 169Yb, 192Ir brachytherapy sources were simulated with MCNPX Monte Carlo code, and their dose rate constant and radial dose function were compared with the published data. A spherical phantom with 50 cm radius was simulated and the dose at various radial distances in adipose tissue, breast tissue, 4-component soft tissue, brain (grey/white matter), muscle (skeletal), lung tissue, blood (whole), 9-component soft tissue, and water were calculated. The absolute dose and relative dose difference with respect to 9-component soft tissue was obtained for various materials, sources, and distances. Results There was good agreement between the dosimetric parameters of the sources and the published data. Adipose tissue, breast tissue, 4-component soft tissue, and water showed the greatest difference in dose relative to the dose to the 9-component soft tissue. The other soft tissues showed lower dose differences. The dose difference was also higher for 103Pd source than for 125I, 169Yb, and 192Ir sources. Furthermore, greater distances from the source had higher relative dose differences and the effect can be justified due to the change in photon spectrum (softening or hardening) as photons traverse the phantom material. Conclusions The ignorance of soft tissue characteristics (density, composition, etc.) by treatment planning systems incorporates a significant error in dose delivery to the patient in brachytherapy with photon sources. The error depends on the type of soft tissue, brachytherapy source, as well as the distance from the source. PMID:24790623

  17. Prevention of intra-abdominal adhesion by bi-layer electrospun membrane.

    PubMed

    Jiang, Shichao; Wang, Wei; Yan, Hede; Fan, Cunyi

    2013-06-04

    The aim of this study was to compare the anti-adhesion efficacy of a bi-layer electrospun fibrous membrane consisting of hyaluronic acid-loaded poly(ε-caprolactone) (PCL) fibrous membrane as the inner layer and PCL fibrous membrane as the outer layer with a single-layer PCL electrospun fibrous membrane in a rat cecum abrasion model. The rat model utilized a cecal abrasion and abdominal wall insult surgical protocol. The bi-layer and PCL membranes were applied between the cecum and the abdominal wall, respectively. Control animals did not receive any treatment. After postoperative day 14, a visual semiquantitative grading scale was used to grade the extent of adhesion. Histological analysis was performed to reveal the features of adhesion tissues. Bi-layer membrane treated animals showed significantly lower adhesion scores than control animals (p < 0.05) and a lower adhesion score compared with the PCL membrane. Histological analysis of the bi-layer membrane treated rat rarely demonstrated tissue adhesion while that of the PCL membrane treated rat and control rat showed loose and dense adhesion tissues, respectively. Bi-layer membrane can efficiently prevent adhesion formation in abdominal cavity and showed a significantly decreased adhesion tissue formation compared with the control.

  18. The Effect of Two Soft Drinks on Bracket Bond Strength and on Intact and Sealed Enamel: An In Vitro Study.

    PubMed

    Pasha, Azam; Sindhu, D; Nayak, Rabindra S; Mamatha, J; Chaitra, K R; Vishwakarma, Swati

    2015-01-01

    This study was conducted to evaluate the effect of two soft drinks, Coca-Cola and Mirinda orange on bracket bond strength, on adhesive remnant on teeth after debonding the bracket, and to observe by means of scanning electron microscope (SEM) the effect of these drinks on intact and sealed enamel. 120 non-carious maxillary premolar teeth already extracted for Orthodontic purposes were taken and divided into three groups, i.e., Coca-Cola drink, Mirinda orange, and control (artificial saliva) group. Brackets were bonded using conventional methods. Teeth were kept in soft drinks for 15 days, for 15 min, 3 times a day, separated by intervals of 2 h. At other times, they were kept in artificial saliva. The samples, thus obtained were evaluated for shear bond strength using the universal testing machine and subsequently subjected for adhesive remnant index (ARI) scores. SEM study on all the three groups was done for evaluating enamel surface of the intact and sealed enamel. The lowest mean resistance to shearing forces was shown by Mirinda orange group (5.30 ± 2.74 Mpa) followed by Coca-Cola group (6.24 ± 1.59 Mpa) and highest resistance to shearing forces by control group (7.33 ± 1.72 Mpa). The ARI scores revealed a cohesive failure in control samples and an adhesive failure in Mirinda and cola samples. SEM results showed areas of defect due to erosion caused by acidic soft drinks on intact and sealed enamel surface. Mirinda group showed the lowest resistance to shearing forces, followed by Coca-Cola group and with the highest resistance to shearing forces by the control group. There were significant differences between the control group and the study groups. Areas of defects, which were caused by erosion related to acidic soft drinks on the enamel surface around the adhesive, were seen. Areas of defects caused by Coca-Cola were more extensive when compared to Mirinda orange drink.

  19. Melorheostosis of the axial skeleton with associated fibrolipomatous lesions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garver, P.; Resnick, D.; Haghighi, P.

    1982-11-01

    Two patients with melorheostotic-like lesions of the axial skeleton are described. In each case adjacent soft tissue masses containing both fatty and fibrous tissues were evident. The presence of such soft tissue tumors as well as other soft tissue abnormalities in melorheostosis emphasizes that the diesease should not be regarded as one confined to bone. The precise pathogenesis of the osseous and soft tissue abnormalities in melorheostosis remains obscure.

  20. Mechanical verification of soft-tissue attachment on bioactive glasses and titanium implants.

    PubMed

    Zhao, Desheng; Moritz, Niko; Vedel, Erik; Hupa, Leena; Aro, Hannu T

    2008-07-01

    Soft-tissue attachment is a desired feature of many clinical biomaterials. The aim of the current study was to design a suitable experimental method for tensile testing of implant incorporation with soft-tissues. Conical implants were made of three compositions of bioactive glass (SiO(2)-P(2)O(5)-B(2)O(3)-Na(2)O-K(2)O-CaO-MgO) or titanium fiber mesh (porosity 84.7%). The implants were surgically inserted into the dorsal subcutaneous soft-tissue or back muscles in the rat. Soft-tissue attachment was evaluated by pull-out testing using a custom-made jig 8 weeks after implantation. Titanium fiber mesh implants had developed a relatively high pull-out force in subcutaneous tissue (12.33+/-5.29 N, mean+/-SD) and also measurable attachment with muscle tissue (2.46+/-1.33 N). The bioactive glass implants failed to show mechanically relevant soft-tissue bonding. The experimental set-up of mechanical testing seems to be feasible for verification studies of soft-tissue attachment. The inexpensive small animal model is beneficial for large-scale in vivo screening of new biomaterials.

  1. Neurosurgical patties: adhesion and damage mitigation.

    PubMed

    Stratton-Powell, Ashley A; Anderson, Ian A; Timothy, Jake; Kapur, Nikil; Culmer, Peter

    2015-07-01

    Neurosurgical patties are textile pads used during most neurosurgical operations to protect tissues, manage the fluid environment, control hemostasis, and aid tissue manipulation. Recent research has suggested that, contrary to their aim, patties adhere to brain tissue and cause damage during removal. This study aimed to characterize and quantify the degree of and consequences resulting from adhesion between neurosurgical patties and brain tissue. Using a customized peel apparatus, the authors performed 90° peel tests on 5 patty products: Policot, Telfa, Americot, Delicot, and Ray-Cot (n = 247) from American Surgical Company. They tested 4 conditions: wet patty on glass (control), wet patty on wet brain peeled at 5 mm/sec (wet), dry patty on wet brain peeled at 5 mm/sec (dry), and wet patty on wet brain peeled at 20 mm/sec (speed). The interaction between patty and tissue was analyzed using peel-force traces and pre-peel histological analysis. Adhesion strength differed between patty products (p < 0.001) and conditions (p < 0.001). Adhesion strength was greatest for Delicot patties under wet (2.22 mN/mm) and dry (9.88 mN/mm) conditions. For all patties, damage at the patty-tissue interface was proportional to the degree of fiber contact. When patties were irrigated, mechanical adhesion was reduced by up to 550% compared with dry usage. For all patty products, mechanical (destructive) and liquid-mediated (nondestructive) adhesion caused damage to neural tissue. The greatest adhesion occurred with Delicot patties. To mitigate patty adhesion and neural tissue damage, surgeons should consider regular irrigation to be essential during neurosurgical procedures.

  2. Tissue adhesives in otorhinolaryngology

    PubMed Central

    Schneider, Gerlind

    2011-01-01

    The development of medical tissue adhesives has a long history without finding an all-purpose tissue adhesive for clinical daily routine. This is caused by the specific demands which are made on a tissue adhesive, and the different areas of application. In otorhinolaryngology, on the one hand, this is the mucosal environment as well as the application on bones, cartilage and periphery nerves. On the other hand, there are stressed regions (skin, oral cavity, pharynx, oesophagus, trachea) and unstressed regions (middle ear, nose and paranasal sinuses, cranial bones). But due to the facts that adhesives can have considerable advantages in assuring surgery results, prevention of complications and so reduction of medical costs/treatment expenses, the search for new adhesives for use in otorhinolaryngology will be continued intensively. In parallel, appropriate application systems have to be developed for microscopic and endoscopic use. PMID:22073094

  3. Degradable Adhesives for Surgery and Tissue Engineering.

    PubMed

    Bhagat, Vrushali; Becker, Matthew L

    2017-10-09

    This review highlights the research on degradable polymeric tissue adhesives for surgery and tissue engineering. Included are a comprehensive listing of specific uses, advantages, and disadvantages of different adhesive groups. A critical evaluation of challenges affecting the development of next generation materials is also discussed, and insights into the outlook of the field are explored.

  4. Gemcitabine Hydrochloride With or Without Pazopanib Hydrochloride in Treating Patients With Refractory Soft Tissue Sarcoma

    ClinicalTrials.gov

    2017-11-01

    Adult Alveolar Soft Part Sarcoma; Adult Angiosarcoma; Adult Desmoplastic Small Round Cell Tumor; Adult Epithelioid Hemangioendothelioma; Adult Epithelioid Sarcoma; Adult Extraskeletal Myxoid Chondrosarcoma; Adult Extraskeletal Osteosarcoma; Adult Fibrosarcoma; Adult Leiomyosarcoma; Adult Liposarcoma; Adult Malignant Mesenchymoma; Adult Malignant Peripheral Nerve Sheath Tumor; Adult Rhabdomyosarcoma; Adult Synovial Sarcoma; Adult Undifferentiated Pleomorphic Sarcoma; Malignant Adult Hemangiopericytoma; Recurrent Adult Soft Tissue Sarcoma; Stage III Adult Soft Tissue Sarcoma; Stage IV Adult Soft Tissue Sarcoma

  5. Depsipeptide (Romidepsin) in Treating Patients With Metastatic or Unresectable Soft Tissue Sarcoma

    ClinicalTrials.gov

    2017-05-18

    Adult Alveolar Soft-part Sarcoma; Adult Angiosarcoma; Adult Epithelioid Sarcoma; Adult Extraskeletal Chondrosarcoma; Adult Extraskeletal Osteosarcoma; Adult Fibrosarcoma; Adult Leiomyosarcoma; Adult Liposarcoma; Adult Malignant Fibrous Histiocytoma; Adult Malignant Hemangiopericytoma; Adult Malignant Mesenchymoma; Adult Neurofibrosarcoma; Adult Rhabdomyosarcoma; Adult Synovial Sarcoma; Gastrointestinal Stromal Tumor; Metastatic Ewing Sarcoma/Peripheral Primitive Neuroectodermal Tumor; Recurrent Adult Soft Tissue Sarcoma; Recurrent Ewing Sarcoma/Peripheral Primitive Neuroectodermal Tumor; Stage III Adult Soft Tissue Sarcoma; Stage IV Adult Soft Tissue Sarcoma

  6. Mechanical properties, structure, bioadhesion, and biocompatibility of pectin hydrogels.

    PubMed

    Markov, Pavel A; Krachkovsky, Nikita S; Durnev, Eugene A; Martinson, Ekaterina A; Litvinets, Sergey G; Popov, Sergey V

    2017-09-01

    The surface structure, biocompatibility, textural, and adhesive properties of calcium hydrogels derived from 1, 2, and 4% solutions of apple pectin were examined in this study. An increase in the pectin concentration in hydrogels was shown to improve their stability toward elastic and plastic deformation. The elasticity of pectin hydrogels, measured as Young's modulus, ranged from 6 to 100 kPa. The mechanical properties of the pectin hydrogels were shown to correspond to those of soft tissues. The characterization of surface roughness in terms of the roughness profile (Ra) and the root-mean-square deviation of the roughness profile (Rq) indicated an increased roughness profile for hydrogels depending on their pectin concentration. The adhesion of AU2% and AU4% hydrogels to the serosa abdominal wall, liver, and colon was higher than that of the AU1% hydrogel. The adhesion of macrophages and the non-specific adsorption of blood plasma proteins were found to increase as the pectin concentration in the hydrogels increased. The rate of degradation of all hydrogels was higher in phosphate buffered saline (PBS) than that in DMEM and a fibroblast cell monolayer. The pectin hydrogel was also found to have a low cytotoxicity. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 2572-2581, 2017. © 2017 Wiley Periodicals, Inc.

  7. How deep cells feel: Mean-field Computations and Experiments

    NASA Astrophysics Data System (ADS)

    Buxboim, Amnon; Sen, Shamik; Discher, Dennis E.

    2009-03-01

    Most cells in solid tissues exert contractile forces that mechanically couple them to elastic surroundings and that significantly influence cell adhesion, cytoskeletal organization and differentiation. However, strains within the depths of matrices are often unclear and are likely relevant to thin matrices, such as basement membranes, relative to cell size as well as to defining how far cells can ``feel.'' We present experimental results for cell spreading on thin, ligand- coated gels and for prestress in stem cells in relation to gel stiffness. Matrix thickness affects cell spread area, focal adhesions and cytoskeleton organization in stem cells, which we will compare to differentiated cells. We introduce a finite element computation to estimate the elastostatic deformations within the matrix on which a cell is placed. Interfacial strains between cell and matrix show large deviations only when soft matrices are a fraction of cell dimensions, proving consistent with experiments. 3-D cell morphologies that model stem cell-derived neurons, myoblasts, and osteoblasts show that a cylinder-shaped myoblast induces the highest strains, consistent with the prominent contractility of muscle. Groups of such cells show a weak crosstalk via matrix strains only when cells are much closer than a cell-width. Cells thus feel on length scales closer to that of adhesions than on cellular scales.

  8. Multifunctional medicated lyophilised wafer dressing for effective chronic wound healing.

    PubMed

    Pawar, Harshavardhan V; Boateng, Joshua S; Ayensu, Isaac; Tetteh, John

    2014-06-01

    Wafers combining weight ratios of Polyox with carrageenan (75/25) or sodium alginate (50/50) containing streptomycin and diclofenac were prepared to improve chronic wound healing. Gels were freeze-dried using a lyophilisation cycle incorporating an annealing step. Wafers were characterised for morphology, mechanical and in vitro functional (swelling, adhesion, drug release in the presence of simulated wound fluid) characteristics. Both blank (BLK) and drug-loaded (DL) wafers were soft, flexible, elegant in appearance and non-brittle in nature. Annealing helped to improve porous nature of wafers but was affected by the addition of drugs. Mechanical characterisation demonstrated that the wafers were strong enough to withstand normal stresses but also flexible to prevent damage to newly formed skin tissue. Differences in swelling, adhesion and drug release characteristics could be attributed to differences in pore size and sodium sulphate formed because of the salt forms of the two drugs. BLK wafers showed relatively higher swelling and adhesion than DL wafers with the latter showing controlled release of streptomycin and diclofenac. The optimised dressing has the potential to reduce bacterial infection and can also help to reduce swelling and pain associated with injury due to the anti-inflammatory action of diclofenac and help to achieve more rapid wound healing. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.

  9. Prevalence of Soft Tissue Calcifications in CBCT Images of Mandibular Region

    PubMed Central

    Khojastepour, Leila; Haghnegahdar, Abdolaziz; Sayar, Hamed

    2017-01-01

    Statement of the Problem: Most of the soft tissue calcifications within the head and neck region might not be accompanied by clinical symptoms but may indicate some pathological conditions. Purpose: The aim of this research was to determine the prevalence of soft tissue calcifications in cone beam computed tomography (CBCT) images of mandibular region. Materials and Method: In this cross sectional study the CBCT images of 602 patients including 294 men and 308 women with mean age 41.38±15.18 years were evaluated regarding the presence, anatomical location; type (single or multiple) and size of soft tissue calcification in mandibular region. All CBCT images were acquired by NewTom VGi scanner. Odds ratio and chi-square tests were used for data analysis and p< 0.05 was considered to be statistically significant. Results: 156 out of 602 patients had at least one soft tissue calcification in their mandibular region (25.9%. of studied population with mean age 51.7±18.03 years). Men showed significantly higher rate of soft tissue calcification than women (30.3% vs. 21.8%). Soft tissue calcification was predominantly seen at posterior region of the mandible (88%) and most of them were single (60.7%). The prevalence of soft tissue calcification increased with age. Most of the detected soft tissue calcifications were smaller than 3mm (90%). Conclusion: Soft tissue calcifications in mandibular area were a relatively common finding especially in posterior region and more likely to happen in men and in older age group. PMID:28620632

  10. Soft tissue changes from maxillary distraction osteogenesis versus orthognathic surgery in patients with cleft lip and palate--a randomized controlled clinical trial.

    PubMed

    Chua, Hannah Daile P; Cheung, Lim Kwong

    2012-07-01

    The objective of this randomized controlled clinical trial was to compare the soft tissue changes after maxillary advancement using conventional orthognathic surgery (CO) and distraction osteogenesis (DO) in patients with cleft lip and palate (CLP). The study group of 39 CLP patients with maxillary hypoplasia underwent either CO or DO with 4 to 10 mm of maxillary advancement. Lateral cephalographs were taken preoperatively and postoperatively at regular intervals. A series of skeletal, dental, and soft tissue landmarks was used to evaluate the changes in the soft tissue and the correlation of hard and soft tissue changes and ratios. Significant differences were found between the CO and DO patients at A point in both maxillary advancement and downgrafting in the early follow-up period. On soft tissue landmarks of pronasale, subnasale, and labial superius, significant differences were found between the 2 groups at 6 months postoperatively only with maxillary advancement. There was better correlation of hard and soft tissue changes with maxillary advancement. The nasal projection was significantly different between the 2 groups at the early and intermediate period. There was much more consistent hard to soft tissue ratios in maxillary advancement with DO than with CO. Both CO and DO can induce significant soft tissue changes of the upper lip and nose, particularly with maxillary advancement. DO generates more consistent hard to soft tissue ratios. Copyright © 2012 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Cabozantinib-S-Malate in Treating Younger Patients With Recurrent, Refractory, or Newly Diagnosed Sarcomas, Wilms Tumor, or Other Rare Tumors

    ClinicalTrials.gov

    2018-06-25

    Adrenal Cortex Carcinoma; Adult Alveolar Soft Part Sarcoma; Adult Clear Cell Sarcoma of Soft Parts; Adult Hepatocellular Carcinoma; Adult Rhabdomyosarcoma; Adult Soft Tissue Sarcoma; Childhood Alveolar Soft Part Sarcoma; Childhood Central Nervous System Neoplasm; Childhood Clear Cell Sarcoma of Soft Parts; Childhood Hepatocellular Carcinoma; Childhood Rhabdomyosarcoma; Childhood Soft Tissue Sarcoma; Childhood Solid Neoplasm; Ewing Sarcoma; Hepatoblastoma; Hepatocellular Carcinoma; Recurrent Adrenal Cortex Carcinoma; Recurrent Adult Hepatocellular Carcinoma; Recurrent Adult Soft Tissue Sarcoma; Recurrent Alveolar Soft Part Sarcoma; Recurrent Childhood Central Nervous System Neoplasm; Recurrent Childhood Hepatocellular Carcinoma; Recurrent Childhood Soft Tissue Sarcoma; Recurrent Ewing Sarcoma; Recurrent Hepatoblastoma; Recurrent Malignant Solid Neoplasm; Recurrent Osteosarcoma; Recurrent Renal Cell Carcinoma; Recurrent Rhabdomyosarcoma; Refractory Osteosarcoma; Renal Cell Carcinoma; Thyroid Gland Medullary Carcinoma; Wilms Tumor

  12. Quantitative morphology in canine cutaneous soft tissue sarcomas.

    PubMed

    Simeonov, R; Ananiev, J; Gulubova, M

    2015-12-01

    Stained cytological specimens from 24 dogs with spontaneous soft tissue sarcomas [fibrosarcoma (n = 8), liposarcoma (n = 8) and haemangiopericytoma (n = 8)], and 24 dogs with reactive connective tissue lesions [granulation tissue (n = 12) and dermal fibrosis (n = 12)] were analysed by computer-assisted nuclear morphometry. The studied morphometric parameters were: mean nuclear area (MNA; µm(2)), mean nuclear perimeter (MNP; µm), mean nuclear diameter (MND mean; µm), minimum nuclear diameter (Dmin; µm) and maximum nuclear diameter (Dmax; µm). The study aimed to evaluate (1) possibility for quantitative differentiation of soft tissue sarcomas from reactive connective tissue lesions and (2) by using cytomorphometry, to differentiate the various histopathological soft tissue sarcomas subtypes in dogs. The mean values of all nuclear cytomorphometric parameters (except for Dmax) were statistically significantly higher in reactive connective tissue processes than in soft tissue sarcomas. At the same time, however, there were no considerable differences among the different sarcoma subtypes. The results demonstrated that the quantitative differentiation of reactive connective tissue processes from soft tissue sarcomas in dogs is possible, but the same was not true for the different canine soft tissue sarcoma subtypes. Further investigations on this topic are necessary for thorough explication of the role of quantitative morphology in the diagnostics of mesenchymal neoplasms and tumour-like fibrous lesions in dogs. © 2014 John Wiley & Sons Ltd.

  13. [Fitting of the reconstructed craniofacial hard and soft tissues based on 2-D digital radiographs].

    PubMed

    Feng, Yao-Pu; Qiao, Min; Zhou, Hong; Zhang, Yan-Ning; Si, Xin-Qin

    2017-02-01

    In this study, we reconstructed the craniofacial hard and soft tissues based on the data from digital cephalometric radiographs and laser scanning. The effective fitting of the craniofacial hard and soft tissues was performed in order to increase the level of orthognathic diagnosis and treatment, and promote the communication between doctors and patients. A small lead point was put on the face of a volunteer and frontal and lateral digital cephalometric radiographs were taken. 3-D reconstruction system of the craniofacial hard tissue based on 2-D digital radiograph was used to get the craniofacial hard tissue model by means of hard tissue deformation modeling. 3-D model of facial soft tissue was obtained by using laser scanning data. By matching the lead point coordinate, the hard tissue and soft tissue were fitted. The 3-D model of the craniofacial hard and soft tissues was rebuilt reflecting the real craniofacial tissue structure, and effective fitting of the craniofacial hard and soft tissues was realized. The effective reconstruction and fitting of the 3-D craniofacial structures have been realized, which lays a foundation for further orthognathic simulation and facial appearance prediction. The fitting result is reliable, and could be used in clinical practice.

  14. The Diagnostic and Prognostic Value of Hematological and Chemical Abnormalities in Soft Tissue Sarcoma: A Comparative Study in Patients with Benign and Malignant Soft Tissue Tumors.

    PubMed

    Ariizumi, Takashi; Kawashima, Hiroyuki; Ogose, Akira; Sasaki, Taro; Hotta, Tetsuo; Hatano, Hiroshi; Morita, Tetsuro; Endo, Naoto

    2018-01-01

    The value of routine blood tests in malignant soft tissue tumors remains uncertain. To determine if these tests can be used for screening, the routine pretreatment blood test findings were retrospectively investigated in 359 patients with benign and malignant soft tissue tumors. Additionally, the prognostic potential of pretreatment blood abnormalities was evaluated in patients with soft tissue sarcomas. We compared clinical factors and blood tests findings between patients with benign and malignant soft tissue tumors using univariate and multivariate analysis. Subsequently, patients with malignant tumors were divided into two groups based on blood test reference values, and the prognostic significance of each parameter was evaluated. In the univariate analysis, age, tumor size, and tumor depth were significant clinical diagnostic factors. Significant increases in the granulocyte count, C-reactive protein (CRP) level, erythrocyte sedimentation rate (ESR), and γ-glutamyl transpeptidase (γ-GTP) levels were found in patients with malignant soft tissue tumors. Multiple logistic regression showed that tumor size and ESR were independent factors that predicted malignant soft tissue tumors. The Kaplan-Meier survival analysis revealed that granulocyte counts, γ-GTP levels, and CRP levels correlated significantly with overall survival. Thus, pretreatment routine blood tests are useful diagnostic and prognostic markers for diagnosing soft tissue sarcoma. © 2018 by the Association of Clinical Scientists, Inc.

  15. Radiation Therapy With or Without Combination Chemotherapy or Pazopanib Hydrochloride Before Surgery in Treating Patients With Newly Diagnosed Non-rhabdomyosarcoma Soft Tissue Sarcomas That Can Be Removed by Surgery

    ClinicalTrials.gov

    2018-06-20

    Adult Fibrosarcoma; Alveolar Soft Part Sarcoma; Angiomatoid Fibrous Histiocytoma; Atypical Fibroxanthoma; Clear Cell Sarcoma of Soft Tissue; Epithelioid Malignant Peripheral Nerve Sheath Tumor; Epithelioid Sarcoma; Extraskeletal Myxoid Chondrosarcoma; Extraskeletal Osteosarcoma; Fibrohistiocytic Neoplasm; Glomus Tumor of the Skin; Inflammatory Myofibroblastic Tumor; Intimal Sarcoma; Leiomyosarcoma; Liposarcoma; Low Grade Fibromyxoid Sarcoma; Low Grade Myofibroblastic Sarcoma; Malignant Cutaneous Granular Cell Tumor; Malignant Peripheral Nerve Sheath Tumor; Malignant Triton Tumor; Mesenchymal Chondrosarcoma; Myxofibrosarcoma; Myxoid Chondrosarcoma; Myxoinflammatory Fibroblastic Sarcoma; Nerve Sheath Neoplasm; PEComa; Pericytic Neoplasm; Plexiform Fibrohistiocytic Tumor; Sclerosing Epithelioid Fibrosarcoma; Stage IB Soft Tissue Sarcoma AJCC v7; Stage IIB Soft Tissue Sarcoma AJCC v7; Stage III Soft Tissue Sarcoma AJCC v7; Stage IV Soft Tissue Sarcoma AJCC v7; Synovial Sarcoma; Undifferentiated (Embryonal) Sarcoma; Undifferentiated High Grade Pleomorphic Sarcoma of Bone

  16. National Training Course. Emergency Medical Technician. Paramedic. Instructor's Lesson Plans. Module VIII. Soft Tissue Injuries.

    ERIC Educational Resources Information Center

    National Highway Traffic Safety Administration (DOT), Washington, DC.

    This instructor's lesson plan guide on soft tissue injuries is one of fifteen modules designed for use in the training of emergency medical technicians (paramedics). Six units of study are presented: (1) anatomy and physiology of the skin; (2) patient assessment for soft-tissue injuries; (3) pathophysiology and management of soft tissue injuries;…

  17. EF5 to Evaluate Tumor Hypoxia in Patients With High-Grade Soft Tissue Sarcoma or Mouth Cancer

    ClinicalTrials.gov

    2013-01-15

    Stage I Adult Soft Tissue Sarcoma; Stage I Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage II Adult Soft Tissue Sarcoma; Stage II Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage III Adult Soft Tissue Sarcoma; Stage III Squamous Cell Carcinoma of the Lip and Oral Cavity

  18. Modern Soft Tissue Pathology | Center for Cancer Research

    Cancer.gov

    This book comprehensively covers modern soft tissue pathology and includes both tumors and non-neoplastic entities. Soft tissues make up a large bulk of the human body, and they are susceptible to a wide range of diseases. Many soft-tissue tumors are biologically very aggressive, and the chance of them metastasizing to vital organs is quite high. In recent years, the outlook

  19. Utilization of robotic-arm assisted total knee arthroplasty for soft tissue protection.

    PubMed

    Sultan, Assem A; Piuzzi, Nicolas; Khlopas, Anton; Chughtai, Morad; Sodhi, Nipun; Mont, Michael A

    2017-12-01

    Despite the well-established success of total knee arthroplasty (TKA), iatrogenic ligamentous and soft tissue injuries are infrequent, but potential complications that can have devastating impact on clinical outcomes. These injuries are often related to technical errors and excessive soft tissue manipulation, particularly during bony resections. Recently, robotic-arm assisted TKA was introduced and demonstrated promising results with potential technical advantages over manual surgery in implant positioning and mechanical accuracy. Furthermore, soft tissue protection is an additional potential advantage offered by these systems that can reduce inadvertent human technical errors encountered during standard manual resections. Therefore, due to the relative paucity of literature, we attempted to answer the following questions: 1) does robotic-arm assisted TKA offer a technical advantage that allows enhanced soft tissue protection? 2) What is the available evidence about soft tissue protection? Recently introduced models of robotic-arm assisted TKA systems with advanced technology showed promising clinical outcomes and soft tissue protection in the short- and mid-term follow-up with results comparable or superior to manual TKA. In this review, we attempted to explore this dimension of robotics in TKA and investigate the soft tissue related complications currently reported in the literature.

  20. A novel injectable tissue adhesive based on oxidized dextran and chitosan.

    PubMed

    Balakrishnan, Biji; Soman, Dawlee; Payanam, Umashanker; Laurent, Alexandre; Labarre, Denis; Jayakrishnan, Athipettah

    2017-04-15

    A surgical adhesive that can be used in different surgical situations with or without sutures is a surgeons' dream and yet none has been able to fulfill many such demanding requirements. It was therefore a major challenge to develop an adhesive biomaterial that stops bleeding and bond tissues well, which at the same time is non-toxic, biocompatible and yet biodegradable, economically viable and appealing to the surgeon in terms of the simplicity of application in complex surgical situations. With this aim, we developed an in situ setting adhesive based on biopolymers such as chitosan and dextran. Dextran was oxidized using periodate to generate aldehyde functions on the biopolymer and then reacted with chitosan hydrochloride. Gelation occurred instantaneously upon mixing these components and the resulting gel showed good tissue adhesive properties with negligible cytotoxicity and minimal swelling in phosphate buffered saline (PBS). Rheology analysis confirmed the gelation process by demonstrating storage modulus having value higher than loss modulus. Adhesive strength was in the range 200-400gf/cm 2 which is about 4-5 times more than that of fibrin glue at comparable setting times. The adhesive showed burst strength in the range of 400-410mm of Hg which should make the same suitable as a sealant for controlling bleeding in many surgical situations even at high blood pressure. Efficacy of the adhesive as a hemostat was demonstrated in a rabbit liver injury model. Histological features after two weeks were comparable to that of commercially available BioGlue®. The adhesive also demonstrated its efficacy as a drug delivery vehicle. The present adhesive could function without the many toxicity and biocompatibility issues associated with such products. Though there are many tissue adhesives available in market, none are free of shortcomings. The newly developed surgical adhesive is a 2-component adhesive system based on time-tested, naturally occurring polysaccharides such as chitosan and dextran which are both biocompatible and biodegradable. Simple polymer modification has been carried out on both polysaccharides so that when aqueous solutions of both are mixed, the solutions gel in less than 10s and forms an adhesive that seals a variety of incisions. The strength of the adhesive is over 5-times the strength of commercially available Fibrin glue and is more tissue compliant than BioGlue®. This adhesive biomaterial showed excellent tissue bonding, was hemostatic, biocompatible and biodegradable. The significance of this work lies on the features of the developed tissue adhesive that it stops bleeding, bond the tissues well, can act as a drug delivery vehicle and would appeal to the surgeon in terms of the simplicity of application in complex surgical situations. There is no need for special delivery systems for application of this adhesive. The two-component adhesive can be applied one over the other using syringes. There is also no need for light curing with UV or visible light and the gelation between the two components spontaneously takes place on application leading to excellent tissue bonding. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  1. Simulated microgravity does not alter epithelial cell adhesion to matrix and other molecules

    NASA Technical Reports Server (NTRS)

    Jessup, J. M.; Brown, K.; Ishii, S.; Ford, R.; Goodwin, T. J.; Spaulding, G.

    1994-01-01

    Microgravity has advantages for the cultivation of tissues with high fidelity; however, tissue formation requires cellular recognition and adhesion. We tested the hypothesis that simulated microgravity does not affect cell adhesion. Human colorectal carcinoma cells were cultured in the NASA Rotating Wall Vessel (RWV) under low shear stress with randomization of the gravity vector that simulates microgravity. After 6 - 7 days, cells were assayed for binding to various substrates and compared to cells grown in standard tissue culture flasks and static suspension cultures. The RWV cultures bound as well to basement membrane proteins and to Carcinoembryonic Antigen (CEA), an intercellular adhesion molecule, as control cultures did. Thus, microgravity does not alter epithelial cell adhesion and may be useful for tissue engineering.

  2. Effect of bone-soft tissue friction on ultrasound axial shear strain elastography

    NASA Astrophysics Data System (ADS)

    Tang, Songyuan; Chaudhry, Anuj; Kim, Namhee; Reddy, J. N.; Righetti, Raffaella

    2017-08-01

    Bone-soft tissue friction is an important factor affecting several musculoskeletal disorders, frictional syndromes and the ability of a bone fracture to heal. However, this parameter is difficult to determine using non-invasive imaging modalities, especially in clinical settings. Ultrasound axial shear strain elastography is a non-invasive imaging modality that has been used in the recent past to estimate the bonding between different tissue layers. As most elastography methods, axial shear strain elastography is primarily used in soft tissues. More recently, this technique has been proposed to assess the bone-soft tissue interface. In this paper, we investigate the effect of a variation in bone-soft tissue friction coefficient in the resulting axial shear strain elastograms. Finite element poroelastic models of bone specimens exhibiting different bone-soft tissue friction coefficients were created and mechanically analyzed. These models were then imported to an ultrasound elastography simulation module to assess the presence of axial shear strain patterns. In vitro experiments were performed to corroborate selected simulation results. The results of this study show that the normalized axial shear strain estimated at the bone-soft tissue interface is statistically correlated to the bone-soft tissue coefficient of friction. This information may prove useful to better interpret ultrasound elastography results obtained in bone-related applications and, possibly, monitor bone healing.

  3. Effect of bone-soft tissue friction on ultrasound axial shear strain elastography.

    PubMed

    Tang, Songyuan; Chaudhry, Anuj; Kim, Namhee; Reddy, J N; Righetti, Raffaella

    2017-07-12

    Bone-soft tissue friction is an important factor affecting several musculoskeletal disorders, frictional syndromes and the ability of a bone fracture to heal. However, this parameter is difficult to determine using non-invasive imaging modalities, especially in clinical settings. Ultrasound axial shear strain elastography is a non-invasive imaging modality that has been used in the recent past to estimate the bonding between different tissue layers. As most elastography methods, axial shear strain elastography is primarily used in soft tissues. More recently, this technique has been proposed to assess the bone-soft tissue interface. In this paper, we investigate the effect of a variation in bone-soft tissue friction coefficient in the resulting axial shear strain elastograms. Finite element poroelastic models of bone specimens exhibiting different bone-soft tissue friction coefficients were created and mechanically analyzed. These models were then imported to an ultrasound elastography simulation module to assess the presence of axial shear strain patterns. In vitro experiments were performed to corroborate selected simulation results. The results of this study show that the normalized axial shear strain estimated at the bone-soft tissue interface is statistically correlated to the bone-soft tissue coefficient of friction. This information may prove useful to better interpret ultrasound elastography results obtained in bone-related applications and, possibly, monitor bone healing.

  4. Direct microCT imaging of non-mineralized connective tissues at high resolution.

    PubMed

    Naveh, Gili R S; Brumfeld, Vlad; Dean, Mason; Shahar, Ron; Weiner, Steve

    2014-01-01

    The 3D imaging of soft tissues in their native state is challenging, especially when high resolution is required. An X-ray-based microCT is, to date, the best choice for high resolution 3D imaging of soft tissues. However, since X-ray attenuation of soft tissues is very low, contrasting enhancement using different staining materials is needed. The staining procedure, which also usually involves tissue fixation, causes unwanted and to some extent unknown tissue alterations. Here, we demonstrate that a method that enables 3D imaging of soft tissues without fixing and staining using an X-ray-based bench-top microCT can be applied to a variety of different tissues. With the sample mounted in a custom-made loading device inside a humidity chamber, we obtained soft tissue contrast and generated 3D images of fresh, soft tissues with a resolution of 1 micron voxel size. We identified three critical conditions which make it possible to image soft tissues: humidified environment, mechanical stabilization of the sample and phase enhancement. We demonstrate the capability of the technique using different specimens: an intervertebral disc, the non-mineralized growth plate, stingray tessellated radials (calcified cartilage) and the collagenous network of the periodontal ligament. Since the scanned specimen is fresh an interesting advantage of this technique is the ability to scan a specimen under load and track the changes of the different structures. This method offers a unique opportunity for obtaining valuable insights into 3D structure-function relationships of soft tissues.

  5. Gelatin- and starch-based hydrogels. Part B: In vitro mesenchymal stem cell behavior on the hydrogels.

    PubMed

    Van Nieuwenhove, Ine; Salamon, Achim; Adam, Stefanie; Dubruel, Peter; Van Vlierberghe, Sandra; Peters, Kirsten

    2017-04-01

    Tissue regeneration often occurs only to a limited extent. By providing a three-dimensional matrix serving as a surrogate extracellular matrix that promotes adult stem cell adhesion, proliferation and differentiation, scaffold-guided tissue regeneration aims at overcoming this limitation. In this study, we applied hydrogels made from crosslinkable gelatin, the hydrolyzed form of collagen, and functionalized starch which were characterized in depth and optimized as described in Van Nieuwenhove et al., 2016. "Gelatin- and Starch-Based Hydrogels. Part A: Hydrogel Development, Characterization and Coating", Carbohydrate Polymers 152:129-39. Collagen is the main structural protein in animal connective tissue and the most abundant protein in mammals. Starch is a carbohydrate consisting of a mixture of amylose and amylopectin. Hydrogels were developed with varying chemical composition (ratio of starch to gelatin applied) and different degrees of methacrylation of the applied gelatin phase. The hydrogels used exhibited no adverse effect on viability of the stem cells cultured on them. Moreover, initial cell adhesion did not differ significantly between them, while the strongest proliferation was observed on the hydrogel with the highest degree of cross-linking. On the least crosslinked and thus most flexible hydrogels, the highest degree of adipogenic differentiation was found, while osteogenic differentiation was the strongest on the most rigid, starch-blended hydrogels. Hydrogel coating with extracellular matrix compounds aggrecan or fibronectin prior to cell seeding exhibited no significant effects. Thus, gelatin-based hydrogels can be optimized regarding maximum promotion of either adipogenic or osteogenic stem cell differentiation in vitro, which makes them promising candidates for in vivo evaluation in clinical studies aiming at either soft or hard tissue regeneration. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. The possibility of clinical application of the solid state lasers: Nd:YAG, Ho:YAG, and Er:YAG in otolaryngology - head and neck surgery

    NASA Astrophysics Data System (ADS)

    Tomaszewska, M.; Kukwa, A.; Tulibacki, M.; Wójtowicz, P.; Olędzka, I.; Jeżewska, E.

    2007-02-01

    The purpose of this study was to summarize our experiences in clinical application of Nd:YAG, Ho:YAG and Er:YAG in otolaryngology- head and neck surgery. Choosing the laser type and parameters for the particular procedures was based on our previous research on tissue effects of those lasers. During the period of 1993-2006 we performed 3988 surgical procedures with the Nd:YAG laser. Over 87% of those were made for the nasal cavity pathologies as polyps, hyperplasia of inferior nasal turbinate, granulation tissue, postoperative adhesions, vascular malformations, under the local anesthesia conditions. In our experience Nd:YAG laser gives the possibility of good clinical control and low risk of side effects for disorders of high recurrence and frequent interventions necessity, as nasal polyps or respiratory papillomatosis. Nd:YAG assisted uvulopalatoplasty gives an interesting alternative for surgical procedures for snoring and slight/mild OSA-recognized patients. Due to its good hemostatic properties, it is a perfect tool for removal of the chemodectoma from meddle ear. During the period of 1995-2006 we performed 229 surgical procedures with the Ho:YAG laser, mostly for larynx pathologies (adhesion and scar tissue removal). In our experience Ho:YAG laser can serve as a precise laser knife for both soft and bony tissue. The ER:YAG laser still remain under clinical trial. Since 2001 year we performed 24 procedures of removing stone deposits from salivary glands. We believe it may become a promising method to cope with sialolithiasis which allows for glandule function preservation. All of the laser types mentioned above, can be easily coupled with endoscopes, what makes them available for all of the head and necklocalized disorders.

  7. Local deformation for soft tissue simulation

    PubMed Central

    Omar, Nadzeri; Zhong, Yongmin; Smith, Julian; Gu, Chengfan

    2016-01-01

    ABSTRACT This paper presents a new methodology to localize the deformation range to improve the computational efficiency for soft tissue simulation. This methodology identifies the local deformation range from the stress distribution in soft tissues due to an external force. A stress estimation method is used based on elastic theory to estimate the stress in soft tissues according to a depth from the contact surface. The proposed methodology can be used with both mass-spring and finite element modeling approaches for soft tissue deformation. Experimental results show that the proposed methodology can improve the computational efficiency while maintaining the modeling realism. PMID:27286482

  8. Co-micellized Pluronic mixture with thermo-sensitivity and residence stability as an injectable tissue adhesion barrier hydrogel.

    PubMed

    Oh, Se Heang; Kang, Jun Goo; Lee, Jin Ho

    2018-01-01

    Although the tissue adhesion which leads to various complications frequently occurs after surgery, the development of an ideal tissue adhesion barrier is still a challenge. In this study, a thermo-sensitive hydrogel, which can fulfill the essential requirements of tissue adhesion barrier (that is, ease of handling for surgeon, flowing down prevention after application, stable residence on the injury during wound healing, and no use of toxic additives), was developed using biocompatible polyethylene glycol-polypropylene glycol copolymers (Pluronic F127/F68/P123 mixture). From the in vitro cell culture and in vivo animal study, it was observed that the Pluronic mixtures showed sol-gel transition at approximately body temperature (for easy injection or coating on the injury site and flowing down prevention after application) and prolonged residence stability in aqueous environment (> ∼7 days for stable protection of injury tissues/organs during wound healing), and thus was highly effective for the prevention of tissue adhesion without adverse tissue responses. Based on these results, the Pluronic F127/F68/P123 mixture itself (without any additives) can be a good candidate as an injectable or coatable tissue adhesion barrier hydrogel applicable to various injury tissues in terms of ease of use, effectiveness, and safety. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 172-182, 2018. © 2016 Wiley Periodicals, Inc.

  9. Contribution of trochanteric soft tissues to fall force estimates, the factor of risk, and prediction of hip fracture risk.

    PubMed

    Bouxsein, Mary L; Szulc, Pawel; Munoz, Fracoise; Thrall, Erica; Sornay-Rendu, Elizabeth; Delmas, Pierre D

    2007-06-01

    We compared trochanteric soft tissue thickness, femoral aBMD, and the ratio of fall force to femoral strength (i.e., factor of risk) in 21 postmenopausal women with incident hip fracture and 42 age-matched controls. Reduced trochanteric soft tissue thickness, low femoral aBMD, and increased ratio of fall force to femoral strength (i.e., factor of risk) were associated with increased risk of hip fracture. The contribution of trochanteric soft tissue thickness to hip fracture risk is incompletely understood. A biomechanical approach to assessing hip fracture risk that compares forces applied to the hip during a sideways fall to femoral strength may by improved by incorporating the force-attenuating effects of trochanteric soft tissues. We determined the relationship between femoral areal BMD (aBMD) and femoral failure load in 49 human cadaveric specimens, 53-99 yr of age. We compared femoral aBMD, trochanteric soft tissue thickness, and the ratio of fall forces to bone strength (i.e., the factor of risk for hip fracture, phi), before and after accounting for the force-attenuating properties of trochanteric soft tissue in 21 postmenopausal women with incident hip fracture and 42 age-matched controls. Femoral aBMD correlated strongly with femoral failure load (r2 = 0.73-0.83). Age, height, and weight did not differ; however, women with hip fracture had lower total femur aBMD (OR = 2.06; 95% CI, 1.19-3.56) and trochanteric soft tissue thickness (OR = 1.82; 95% CI, 1.01, 3.31). Incorporation of trochanteric soft tissue thickness measurements reduced the estimates of fall forces by approximately 50%. After accounting for force-attenuating properties of trochanteric soft tissue, the ratio of fall forces to femoral strength was 50% higher in cases than controls (0.92 +/- 0.44 versus 0.65 +/- 0.50, respectively; p = 0.04). It is possible to compute a biomechanically based estimate of hip fracture risk by combining estimates of femoral strength based on an empirical relationship between femoral aBMD and bone strength in cadaveric femora, along with estimates of loads applied to the hip during a sideways fall that account for thickness of trochanteric soft tissues. Our findings suggest that trochanteric soft tissue thickness may influence hip fracture risk by attenuating forces applied to the femur during a sideways fall and provide rationale for developing improved measurements of trochanteric soft tissue and for studying a larger cohort to determine whether trochanteric soft tissue thickness contributes to hip fracture risk independently of aBMD.

  10. Checklist and Scoring System for the Assessment of Soft Tissue Preservation in CT Examinations of Human Mummies: Application to the Tyrolean Iceman.

    PubMed

    Panzer, Stephanie; Pernter, Patrizia; Piombino-Mascali, Dario; Jankauskas, Rimantas; Zesch, Stephanie; Rosendahl, Wilfried; Hotz, Gerhard; Zink, Albert R

    2017-12-01

    Purpose  Soft tissues make a skeleton into a mummy and they allow for a diagnosis beyond osteology. Following the approach of structured reporting in clinical radiology, a recently developed checklist was used to evaluate the soft tissue preservation status of the Tyrolean Iceman using computed tomography (CT). The purpose of this study was to apply the "Checklist and Scoring System for the Assessment of Soft Tissue Preservation in CT Examinations of Human Mummies" to the Tyrolean Iceman, and to compare the Iceman's soft tissue preservation score to the scores calculated for other mummies. Materials and Methods  A whole-body (CT) (SOMATOM Definition Flash, Siemens, Forchheim, Germany) consisting of five scans, performed in January 2013 in the Department of Radiodiagnostics, Central Hospital, Bolzano, was used (slice thickness 0.6 mm; kilovolt ranging from 80 to 140). For standardized evaluation the "CT Checklist and Scoring System for the Assessment of Soft Tissue Preservation in Human Mummies" was used. Results  All checkpoints under category "A. Soft Tissues of Head and Musculoskeletal System" and more than half in category "B. Organs and Organ Systems" were observed. The scoring system accounted for a total score of 153 (out of 200). The comparison of the scores between the Iceman and three mummy collections from Vilnius, Lithuania, and Palermo, Sicily, as well as one Egyptian mummy resulted in overall higher soft tissue preservation scores for the Iceman. Conclusion  Application of the checklist allowed for standardized assessment and documentation of the Iceman's soft tissue preservation status. The scoring system allowed for a quantitative comparison between the Iceman and other mummies. The Iceman showed remarkable soft tissue preservation. Key Points   · The approach of structured reporting can be transferred to paleoradiology.. · The checklist allowed for standardized soft tissue assessment and documentation.. · The scoring system facilitated a quantitative comparison among mummies.. · Based on CT, the Tyrolean Iceman demonstrated remarkable soft tissue preservation.. Citation Format · Panzer S, Pernter P, Piombino-Mascali D et al. Checklist and Scoring System for the Assessment of Soft Tissue Preservation in CT Examinations of Human Mummies: Application to the Tyrolean Iceman. Fortschr Röntgenstr 2017; 189: 1152 - 1160. © Georg Thieme Verlag KG Stuttgart · New York.

  11. Role of cellular adhesions in tissue dynamics spectroscopy

    NASA Astrophysics Data System (ADS)

    Merrill, Daniel A.; An, Ran; Turek, John; Nolte, David

    2014-02-01

    Cellular adhesions play a critical role in cell behavior, and modified expression of cellular adhesion compounds has been linked to various cancers. We tested the role of cellular adhesions in drug response by studying three cellular culture models: three-dimensional tumor spheroids with well-developed cellular adhesions and extracellular matrix (ECM), dense three-dimensional cell pellets with moderate numbers of adhesions, and dilute three-dimensional cell suspensions in agarose having few adhesions. Our technique for measuring the drug response for the spheroids and cell pellets was biodynamic imaging (BDI), and for the suspensions was quasi-elastic light scattering (QELS). We tested several cytoskeletal chemotherapeutic drugs (nocodazole, cytochalasin-D, paclitaxel, and colchicine) on three cancer cell lines chosen from human colorectal adenocarcinoma (HT-29), human pancreatic carcinoma (MIA PaCa-2), and rat osteosarcoma (UMR-106) to exhibit differences in adhesion strength. Comparing tumor spheroid behavior to that of cell suspensions showed shifts in the spectral motion of the cancer tissues that match predictions based on different degrees of cell-cell contacts. The HT-29 cell line, which has the strongest adhesions in the spheroid model, exhibits anomalous behavior in some cases. These results highlight the importance of using three-dimensional tissue models in drug screening with cellular adhesions being a contributory factor in phenotypic differences between the drug responses of tissue and cells.

  12. Iatrogenic Bone and Soft Tissue Trauma in Robotic-Arm Assisted Total Knee Arthroplasty Compared With Conventional Jig-Based Total Knee Arthroplasty: A Prospective Cohort Study and Validation of a New Classification System.

    PubMed

    Kayani, Babar; Konan, Sujith; Pietrzak, Jurek R T; Haddad, Fares S

    2018-03-27

    The objective of this study was to compare macroscopic bone and soft tissue injury between robotic-arm assisted total knee arthroplasty (RA-TKA) and conventional jig-based total knee arthroplasty (CJ-TKA) and create a validated classification system for reporting iatrogenic bone and periarticular soft tissue injury after TKA. This study included 30 consecutive CJ-TKAs followed by 30 consecutive RA-TKAs performed by a single surgeon. Intraoperative photographs of the femur, tibia, and periarticular soft tissues were taken before implantation of prostheses. Using these outcomes, the macroscopic soft tissue injury (MASTI) classification system was developed to grade iatrogenic bone and soft tissue injuries. Interobserver and Intraobserver validity of the proposed classification system was assessed. Patients undergoing RA-TKA had reduced medial soft tissue injury in both passively correctible (P < .05) and noncorrectible varus deformities (P < .05); more pristine femoral (P < .05) and tibial (P < .05) bone resection cuts; and improved MASTI scores compared to CJ-TKA (P < .05). There was high interobserver (intraclass correlation coefficient 0.92 [95% confidence interval: 0.88-0.96], P < .05) and intraobserver agreement (intraclass correlation coefficient 0.94 [95% confidence interval: 0.92-0.97], P < .05) of the proposed MASTI classification system. There is reduced bone and periarticular soft tissue injury in patients undergoing RA-TKA compared to CJ-TKA. The proposed MASTI classification system is a reproducible grading scheme for describing iatrogenic bone and soft tissue injury in TKA. RA-TKA is associated with reduced bone and soft tissue injury compared with conventional jig-based TKA. The proposed MASTI classification may facilitate further research correlating macroscopic soft tissue injury during TKA to long-term clinical and functional outcomes. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. Motility-Driven Glass and Jamming Transitions in Biological Tissues

    NASA Astrophysics Data System (ADS)

    Bi, Dapeng; Yang, Xingbo; Marchetti, M. Cristina; Manning, M. Lisa

    2016-04-01

    Cell motion inside dense tissues governs many biological processes, including embryonic development and cancer metastasis, and recent experiments suggest that these tissues exhibit collective glassy behavior. To make quantitative predictions about glass transitions in tissues, we study a self-propelled Voronoi model that simultaneously captures polarized cell motility and multibody cell-cell interactions in a confluent tissue, where there are no gaps between cells. We demonstrate that the model exhibits a jamming transition from a solidlike state to a fluidlike state that is controlled by three parameters: the single-cell motile speed, the persistence time of single-cell tracks, and a target shape index that characterizes the competition between cell-cell adhesion and cortical tension. In contrast to traditional particulate glasses, we are able to identify an experimentally accessible structural order parameter that specifies the entire jamming surface as a function of model parameters. We demonstrate that a continuum soft glassy rheology model precisely captures this transition in the limit of small persistence times and explain how it fails in the limit of large persistence times. These results provide a framework for understanding the collective solid-to-liquid transitions that have been observed in embryonic development and cancer progression, which may be associated with epithelial-to-mesenchymal transition in these tissues.

  14. Long-term stability of peri-implant tissues after bone or soft tissue augmentation. Effect of zirconia or titanium abutments on peri-implant soft tissues. Summary and consensus statements. The 4th EAO Consensus Conference 2015.

    PubMed

    Sicilia, Alberto; Quirynen, Marc; Fontolliet, Alain; Francisco, Helena; Friedman, Anton; Linkevicius, Tomas; Lutz, Rainer; Meijer, Henny J; Rompen, Eric; Rotundo, Roberto; Schwarz, Frank; Simion, Massimo; Teughels, Wim; Wennerberg, Ann; Zuhr, Otto

    2015-09-01

    Several surgical techniques and prosthetic devices have been developed in the last decades, aiming to improve aesthetic, hygienic and functional outcomes that may affect the peri-implant tissues, such as procedures of bone and soft tissue augmentation and the use of custom-made abutments of titanium and zirconium. Three systematic reviews, based on randomized clinical trials and prospective studies covering the above reported topics were analysed, and the detected evidence was exposed to interactive experts' discussion during the group's and general assembly's meetings of the 4th EAO Consensus Conference. The results are reported using the following abbreviations: S-T: short-term evidence, M-T: medium-term evidence; L-T: long-term evidence; LE: limited evidence. Soft tissue augmentation procedures may be indicated for the increase of soft tissue thickness and keratinized tissue, the reduction of interproximal peri-implant bone loss, and the coverage of shallow peri-implant soft tissue recessions (S-T, LE), L-T is lacking. Guided bone regeneration approaches (GBR) showed efficacy when used for ridge reconstruction after the complete healing of the soft tissues (S-T & L-T), and the stability of the augmented bone may play a role in the maintenance of the soft tissue position and dimensions (LE). No significant differences were observed between titanium and zirconia abutments when evaluating probing pocket depth, bleeding on probing, marginal bone levels and mucosal recessions. Zirconia abutments were associated with more biological complications but demonstrated superiority in terms of achieving natural soft tissue colour (S-T). © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Theory of Force Regulation by Nascent Adhesion Sites

    PubMed Central

    Bruinsma, Robijn

    2005-01-01

    The mechanical coupling of a cell with the extracellular matrix relies on adhesion sites, clusters of membrane-associated proteins that communicate forces generated along the F-Actin filaments of the cytoskeleton to connecting tissue. Nascent adhesion sites have been shown to regulate these forces in response to tissue rigidity. Force-regulation by substrate rigidity of adhesion sites with fixed area is not possible for stationary adhesion sites, according to elasticity theory. A simple model is presented to describe force regulation by dynamical adhesion sites. PMID:15849245

  16. Doxorubicin With Upfront Dexrazoxane Plus Olaratumab for the Treatment of Advanced or Metastatic Soft Tissue Sarcoma

    ClinicalTrials.gov

    2018-02-08

    Sarcoma, Soft Tissue; Soft Tissue Sarcoma; Undifferentiated Pleomorphic Sarcoma; Leiomyosarcoma; Liposarcoma; Synovial Sarcoma; Myxofibrosarcoma; Angiosarcoma; Fibrosarcoma; Malignant Peripheral Nerve Sheath Tumor; Epithelioid Sarcoma

  17. Bacterial adherence to graft tissues in static and flow conditions.

    PubMed

    Veloso, Tiago Rafael; Claes, Jorien; Van Kerckhoven, Soetkin; Ditkowski, Bartosz; Hurtado-Aguilar, Luis G; Jockenhoevel, Stefan; Mela, Petra; Jashari, Ramadan; Gewillig, Marc; Hoylaerts, Marc F; Meyns, Bart; Heying, Ruth

    2018-01-01

    Various conduits and stent-mounted valves are used as pulmonary valve graft tissues for right ventricular outflow tract reconstruction with good hemodynamic results. Valve replacement carries an increased risk of infective endocarditis (IE). Recent observations have increased awareness of the risk of IE after transcatheter implantation of a stent-mounted bovine jugular vein valve. This study focused on the susceptibility of graft tissue surfaces to bacterial adherence as a potential risk factor for subsequent IE. Adhesion of Staphylococcus aureus, Staphylococcus epidermidis, and Streptococcus sanguinis to bovine pericardium (BP) patch, bovine jugular vein (BJV), and cryopreserved homograft (CH) tissues was quantified under static and shear stress conditions. Microscopic analysis and histology were performed to evaluate bacterial adhesion to matrix components. In general, similar bacteria numbers were recovered from CH and BJV tissue surfaces for all strains, especially in flow conditions. Static bacterial adhesion to the CH wall was lower for S sanguinis adhesion (P < .05 vs BP patch). Adhesion to the BJV wall, CH wall, and leaflet was decreased for S epidermidis in static conditions (P < .05 vs BP patch). Bacterial adhesion under shear stress indicated similar bacterial adhesion to all tissues, except for lower adhesion to the BJV wall after S sanguinis incubation. Microscopic analysis showed the importance of matrix component exposure for bacterial adherence to CH. Our data provide evidence that the surface composition of BJV and CH tissues themselves, bacterial surface proteins, and shear forces per se are not the prime determinants of bacterial adherence. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  18. High-level expression of podoplanin in benign and malignant soft tissue tumors: immunohistochemical and quantitative real-time RT-PCR analysis.

    PubMed

    Xu, Yongjun; Ogose, Akira; Kawashima, Hiroyuki; Hotta, Tetsuo; Ariizumi, Takashi; Li, Guidong; Umezu, Hajime; Endo, Naoto

    2011-03-01

    Podoplanin is a 38 kDa mucin-type transmembrane glycoprotein that was first identified in rat glomerular epithelial cells (podocytes). It is expressed in normal lymphatic endothelium, but is absent from vascular endothelial cells. D2-40 is a commercially available mouse monoclonal antibody which binds to an epitope on human podoplanin. D2-40 immunoreactivity is therefore highly sensitive and specific for lymphatic endothelium. Recent investigations have shown widespread applications of immunohistochemical staining with D2-40 in evaluating podoplanin expression as an immunohistochemical marker for diagnosis and prognosis in various tumors. To determine whether the podoplanin (D2-40) antibody may be useful for the diagnosis of soft tissue tumors, 125 cases, including 4 kinds of benign tumors, 15 kinds of malignant tumors and 3 kinds of tumor-like lesions were immunostained using the D2-40 antibody. Total RNA was extracted from frozen tumor tissue obtained from 41 corresponding soft tissue tumor patients and 12 kinds of soft tissue tumor cell lines. Quantitative real-time PCR reactions were performed. Immunohistochemical and quantitative real-time RT-PCR analyses demonstrated the expression of the podoplanin protein and mRNA in the majority of benign and malignant soft tissue tumors and tumor-like lesions examined, with the exception of alveolar soft part sarcoma, embryonal and alveolar rhabdomyosarcoma, extraskeletal Ewing's sarcoma/peripheral primitive neuro-ectodermal tumor and lipoma, which were completely negative for podoplanin. Since it is widely and highly expressed in nearly all kinds of soft tissue tumors, especially in spindle cell sarcoma, myxoid type soft tissue tumors and soft tissue tumors of the nervous system, podoplanin is considered to have little value in the differential diagnosis of soft tissue tumors.

  19. A Novel Esthetic Approach using Connective Tissue Graft for Soft Tissue Defect Following Surgical Excision of Gingival Fibrolipoma

    PubMed Central

    Parthasarathy, Harinath; Kumar, Praveenkrishna; Gajendran, Priyalochana; Appukuttan, Devapriya

    2014-01-01

    The aim of the present case report is to evaluate the adjunctive use of a connective tissue graft to overcome soft tissue defects following excision of a gingival fibrolipoma in the aesthetic region. Connective tissue graft has been well documented for treating defects of esthetic concern. However, the literature does not contain many reports on the esthetic clinical outcome following the use of connective tissue graft secondary to excision of soft tissue tumours. A 28-year-old male patient reported with a complaint of a recurrent growth in relation to his lower front tooth region. The lesion which was provisionally diagnosed as fibroma was treated with a complete surgical excision, following which a modified coronally advanced flap and connective tissue graft was adopted to overcome the soft tissue defect. The excised growth was diagnosed histologically as fibrolipoma. One year follow up showed no recurrence of the lesion and good esthetics.The adjunctive use of the connective tissue graft and modified coronally advanced flap predictably yields optimal soft tissue fill and excellent esthetics. Hence, routine use of this procedure may be recommended for surgical excision of soft tissue growths in esthetically sensitive areas. PMID:25584336

  20. Evidence-based knowledge on the aesthetics and maintenance of peri-implant soft tissues: Osteology Foundation Consensus Report Part 1-Effects of soft tissue augmentation procedures on the maintenance of peri-implant soft tissue health.

    PubMed

    Giannobile, William V; Jung, Ronald E; Schwarz, Frank

    2018-03-01

    The goal of Working Group 1 at the 2nd Consensus Meeting of the Osteology Foundation was to comprehensively assess the effects of soft tissue augmentation procedures on peri-implant health or disease. A systematic review and meta-analysis on the effects of soft tissue augmentation procedures included a total of 10 studies (mucosal thickness: n = 6; keratinized tissue: n = 4). Consensus statements, clinical recommendations, and implications for future research were based on structured group discussions and a plenary session approval. Soft tissue grafting to increase the width of keratinized tissue around implants was associated with greater reductions in gingival and plaque indices when compared to non-augmented sites. Statistically significant differences were noted for final marginal bone levels in favor of an apically positioned flap plus autogenous graft vs. all standard-of-care control treatments investigated. Soft tissue grafting (i.e., autogenous connective tissue) to increase the mucosal thickness around implants in the aesthetic zone was associated with significantly less marginal bone loss over time, but no significant changes in bleeding on probing, probing depths, or plaque scores when compared to sites without grafting. The limited evidence available supports the use of soft tissue augmentation procedures to promote peri-implant health. © 2018 The Authors. Clinical Oral Implants Research Published by John Wiley & Sons Ltd.

  1. 21 CFR 878.4010 - Tissue adhesive.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4010 Tissue adhesive. (a) Tissue... intended for use in the embolization of brain arteriovenous malformation or for use in ophthalmic surgery...

  2. 21 CFR 878.4010 - Tissue adhesive.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4010 Tissue adhesive. (a) Tissue... intended for use in the embolization of brain arteriovenous malformation or for use in ophthalmic surgery...

  3. 21 CFR 878.4010 - Tissue adhesive.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4010 Tissue adhesive. (a) Tissue... intended for use in the embolization of brain arteriovenous malformation or for use in ophthalmic surgery...

  4. Cixutumumab and Doxorubicin Hydrochloride in Treating Patients With Unresectable, Locally Advanced, or Metastatic Soft Tissue Sarcoma

    ClinicalTrials.gov

    2016-05-16

    Adult Angiosarcoma; Adult Desmoplastic Small Round Cell Tumor; Adult Epithelioid Sarcoma; Adult Extraskeletal Myxoid Chondrosarcoma; Adult Extraskeletal Osteosarcoma; Adult Fibrosarcoma; Adult Leiomyosarcoma; Adult Liposarcoma; Adult Malignant Mesenchymoma; Adult Malignant Peripheral Nerve Sheath Tumor; Adult Rhabdomyosarcoma; Adult Synovial Sarcoma; Adult Undifferentiated High Grade Pleomorphic Sarcoma of Bone; Childhood Angiosarcoma; Childhood Desmoplastic Small Round Cell Tumor; Childhood Epithelioid Sarcoma; Childhood Fibrosarcoma; Childhood Leiomyosarcoma; Childhood Liposarcoma; Childhood Malignant Mesenchymoma; Childhood Malignant Peripheral Nerve Sheath Tumor; Childhood Pleomorphic Rhabdomyosarcoma; Childhood Rhabdomyosarcoma With Mixed Embryonal and Alveolar Features; Childhood Synovial Sarcoma; Dermatofibrosarcoma Protuberans; Malignant Adult Hemangiopericytoma; Malignant Childhood Hemangiopericytoma; Metastatic Childhood Soft Tissue Sarcoma; Previously Treated Childhood Rhabdomyosarcoma; Recurrent Adult Soft Tissue Sarcoma; Recurrent Childhood Rhabdomyosarcoma; Recurrent Childhood Soft Tissue Sarcoma; Stage III Adult Soft Tissue Sarcoma; Stage IV Adult Soft Tissue Sarcoma; Untreated Childhood Rhabdomyosarcoma

  5. Inner power, physical strength and existential well-being in daily life: relatives' experiences of receiving soft tissue massage in palliative home care.

    PubMed

    Cronfalk, Berit Seiger; Strang, Peter; Ternestedt, Britt-Marie

    2009-08-01

    This article explores relatives' experiences of receiving soft tissue massage as a support supplement while caring for a dying family member at home. In palliative home care, relatives play an important role as carers to seriously ill and dying family members. To improve their quality of life, different support strategies are of importance. Complementary methods, such as soft tissue massage have become an appreciated supplement for these patients. However, only few studies focus on relatives experiences of receiving soft tissue massage as a supplemental support. Qualitative design Nineteen relatives received soft tissue massage (hand or foot) nine times (25 minutes) in their homes. Open-ended semi-structured tape-recorded interviews were conducted once per relative after the nine times of massage, using qualitative content analysis. Soft tissue massage gave the relatives' feelings of 'being cared for', 'body vitality' and 'peace of mind'. For a while, they put worries of daily life aside as they just experienced 'being'. During massage, it became apparent that body and mind is constituted of an indestructible completeness. The overarching theme was 'inner power, physical strength and existential well-being in their daily lives'. All relatives experienced soft tissue massage positively, although they were under considerable stress. Soft tissue massage could be an option to comfort and support relatives in palliative home care. In palliative nursing care, soft tissue massage could present a worthy supplement in supporting caring relatives.

  6. Soft tissue thin-plate spline analysis of pre-pubertal Korean and European-Americans with untreated Angle's Class III malocclusions.

    PubMed

    Singh, G D; McNamara, J A; Lozanoff, S

    1999-01-01

    The purpose of this study was to assess soft tissue facial matrices in subjects of diverse ethnic origins with underlying dentoskeletal malocclusions. Pre-treatment lateral cephalographs of 71 Korean and 70 European-American children aged between 5 and 11 years with Angle's Class III malocclusions were traced, and 12 homologous, soft tissue landmarks digitized. Comparing mean Korean and European-American Class III soft tissue profiles, Procrustes analysis established statistical difference (P < 0.001) between the configurations, and this difference was also true at all seven age groups tested (P < 0.001). Comparing the overall European-American and Korean transformation, thin-plate spline analysis indicated that both affine and non-affine transformations contribute towards the total spline (deformation) of the averaged Class III soft tissue configurations. For non-affine transformations, partial warp (PW) 8 had the highest magnitude, indicating large-scale deformations visualized as labio-mental protrusion, predominantly. In addition, PW9, PW4, and PW5 also had high magnitudes, demonstrating labio-mental vertical compression and antero-posterior compression of the lower labio-mental soft tissues. Thus, Korean children with Class III malocclusions demonstrate antero-posterior and vertical deformations of the labio-mental soft tissue complex with respect to their European-American counterparts. Morphological heterogeneity of the soft tissue integument in subjects of diverse ethnic origin may obscure the underlying skeletal morphology, but the soft tissue integument appears to have minimal ontogenetic association with Class III malocclusions.

  7. Neutrophil adhesion and chemotaxis depend on substrate mechanics

    NASA Astrophysics Data System (ADS)

    Jannat, Risat A.; Robbins, Gregory P.; Ricart, Brendon G.; Dembo, Micah; Hammer, Daniel A.

    2010-05-01

    Neutrophil adhesion to the vasculature and chemotaxis within tissues play critical roles in the inflammatory response to injury and pathogens. Unregulated neutrophil activity has been implicated in the progression of numerous chronic and acute diseases such as rheumatoid arthritis, asthma and sepsis. Cell migration of anchorage-dependent cells is known to depend on both chemical and mechanical interactions. Although neutrophil responses to chemical cues have been well characterized, little is known about the effect of underlying tissue mechanics on neutrophil adhesion and migration. To address this question, we quantified neutrophil migration and traction stresses on compliant hydrogel substrates with varying elasticity in a micromachined gradient chamber in which we could apply either a uniform concentration or a precise gradient of the bacterial chemoattractant fMLP. Neutrophils spread more extensively on substrates of greater stiffness. In addition, increasing the stiffness of the substrate leads to a significant increase in the chemotactic index for each fMLP gradient tested. As the substrate becomes stiffer, neutrophils generate higher traction forces without significant changes in cell speed. These forces are often displayed in pairs and focused in the uropod. Increases in the mean fMLP concentration beyond the KD of the receptor lead to a decrease in chemotactic index on all surfaces. Blocking with an antibody against β2-integrins leads to a significant reduction, but not an elimination, of directed motility on stiff materials, but no change in motility on soft materials, suggesting neutrophils can display both integrin-dependent and integrin-independent motility. These findings are critical for understanding how neutrophil migration may change in different mechanical environments in vivo and can be used to guide the design of migration inhibitors that more efficiently target inflammation.

  8. Improved Rubin-Bodner Model for the Prediction of Soft Tissue Deformations

    PubMed Central

    Zhang, Guangming; Xia, James J.; Liebschner, Michael; Zhang, Xiaoyan; Kim, Daeseung; Zhou, Xiaobo

    2016-01-01

    In craniomaxillofacial (CMF) surgery, a reliable way of simulating the soft tissue deformation resulted from skeletal reconstruction is vitally important for preventing the risks of facial distortion postoperatively. However, it is difficult to simulate the soft tissue behaviors affected by different types of CMF surgery. This study presents an integrated bio-mechanical and statistical learning model to improve accuracy and reliability of predictions on soft facial tissue behavior. The Rubin-Bodner (RB) model is initially used to describe the biomechanical behavior of the soft facial tissue. Subsequently, a finite element model (FEM) computers the stress of each node in soft facial tissue mesh data resulted from bone displacement. Next, the Generalized Regression Neural Network (GRNN) method is implemented to obtain the relationship between the facial soft tissue deformation and the stress distribution corresponding to different CMF surgical types and to improve evaluation of elastic parameters included in the RB model. Therefore, the soft facial tissue deformation can be predicted by biomechanical properties and statistical model. Leave-one-out cross-validation is used on eleven patients. As a result, the average prediction error of our model (0.7035mm) is lower than those resulting from other approaches. It also demonstrates that the more accurate bio-mechanical information the model has, the better prediction performance it could achieve. PMID:27717593

  9. Development of a biodegradable tissue adhesive based on functionalized 1,2-ethylene glycol bis(dilactic acid). II.

    PubMed

    Rohm, Henning W; Lurtz, Claudia; Wegmann, Juergen; Odermatt, Erich K; Behrend, Detlef; Schmitz, Klaus-Peter; Sternberg, Katrin

    2011-04-01

    In body regions where damage and bleeding must be avoided, a substitute for mechanical tissue fixation by sutures or staplers is needed. Since tissue adhesives provide easy and fast handling they are a promising alternative. The present study reports the development and analysis of a tissue adhesive that consists of two adhesive components: hexamethylene diisocyanate (HDI) functionalized 1,2-ethylene glycol bis(dilactic acid) (ELA-NCO) and chitosan chloride. This composition was chosen based on preliminary studies on several chain elongation agents. The present study evaluates this adhesive system by IR-spectroscopy, tensile tests, and gel point measurements in comparison to fibrin glue. The system's in vitro biocompatibility was tested with mouse fibroblasts (L929) according to ISO 10993-5. Furthermore, an implantation study was performed in SPF-Wistar rats. The adhesive strength of manually applied mixtures or mixtures applied by double chamber syringes with a mixing extruder was determined to be significantly higher than that of fibrin glue on bovine muscle tissue at 37°C. Tensile strength increased further when exposure time of the adhesive was increased from 10 min to 48 h. The rheological gel point determination showed that the mixture of ELA-NCO/DMSO and chitosan chloride offers a time window large enough to readjust the fused joint during surgery, as opposed to fibrin glue. Additionally, the in vitro and in vivo biocompatibility studies of the adhesive system revealed no toxic effects on the surrounding tissue. Copyright © 2010 Wiley Periodicals, Inc.

  10. Alveolar soft part sarcoma causing perianal abscess.

    PubMed

    Sullivan, Niall; McCulloch, Tom; Leverton, David

    2011-07-01

    A 34-year-old woman presented with a perianal abscess that communicated with the vagina. There was a background of a one-year history of a conservatively treated, traumatic, paravaginal haematoma. Histology of the fistula tract showed alveolar soft part sarcoma and subsequent imaging identified a large soft tissue mass in the pelvis with lung metastases. Alveolar soft part sarcoma is a rare soft tissue sarcoma of unknown cellular origin affecting predominantly young women, often in deep soft tissues and lower extremities.

  11. A PEGylated platelet free plasma hydrogel based composite scaffold enables stable vascularization and targeted cell delivery for volumetric muscle loss.

    PubMed

    Aurora, Amit; Wrice, Nicole; Walters, Thomas J; Christy, Robert J; Natesan, Shanmugasundaram

    2018-01-01

    Extracellular matrix (ECM) scaffolds are being used for the clinical repair of soft tissue injuries. Although improved functional outcomes have been reported, ECM scaffolds show limited tissue specific remodeling response with concomitant deposition of fibrotic tissue. One plausible explanation is the regression of blood vessels which may be limiting the diffusion of oxygen and nutrients across the scaffold. Herein we develop a composite scaffold as a vasculo-inductive platform by integrating PEGylated platelet free plasma (PFP) hydrogel with a muscle derived ECM scaffold (m-ECM). In vitro, adipose derived stem cells (ASCs) seeded onto the composite scaffold differentiated into two distinct morphologies, a tubular network in the hydrogel, and elongated structures along the m-ECM scaffold. The composite scaffold showed a high expression of ITGA5, ITGB1, and FN and a synergistic up-regulation of ang1 and tie-2 transcripts. The in vitro ability of the composite scaffold to provide extracellular milieu for cell adhesion and molecular cues to support vessel formation was investigated in a rodent volumetric muscle loss (VML) model. The composite scaffold delivered with ASCs supported robust and stable vascularization. Additionally, the composite scaffold supported increased localization of ASCs in the defect demonstrating its ability for localized cell delivery. Interestingly, ASCs were observed homing in the injured muscle and around the perivascular space possibly to stabilize the host vasculature. In conclusion, the composite scaffold delivered with ASCs presents a promising approach for scaffold vascularization. The versatile nature of the composite scaffold also makes it easily adaptable for the repair of soft tissue injuries. Decellularized extracellular matrix (ECM) scaffolds when used for soft tissue repair is often accompanied by deposition of fibrotic tissue possibly due to limited scaffold vascularization, which limits the diffusion of oxygen and nutrients across the scaffold. Although a variety of scaffold vascularization strategies has been investigated, their limitations preclude rapid clinical translation. In this study we have developed a composite scaffold by integrating bi-functional polyethylene glycol modified platelet free plasma (PEGylated PFP) with adipose derived stem cells (ASCs) along with a muscle derived ECM scaffold (m-ECM). The composite scaffold provides a vasculo-inductive and an effective cell delivery platform for volumetric muscle loss. Copyright © 2017 Acta Materialia Inc. All rights reserved.

  12. Late revision or correction of facial trauma-related soft-tissue deformities.

    PubMed

    Rieck, Kevin L; Fillmore, W Jonathan; Ettinger, Kyle S

    2013-11-01

    Surgical approaches used in accessing the facial skeleton for fracture repair are often the same as or similar to those used for cosmetic enhancement of the face. Rarely does facial trauma result in injuries that do not in some way affect the facial soft-tissue envelope either directly or as sequelae of the surgical repair. Knowledge of both skeletal and facial soft-tissue anatomy is paramount to successful clinical outcomes. Facial soft-tissue deformities can arise that require specific evaluation and management for correction. This article focuses on revision and correction of these soft-tissue-related injuries secondary to facial trauma. Copyright © 2013. Published by Elsevier Inc.

  13. The in vitro and in vivo influence of 4-META/MMA-TBB resin components on dental pulp tissues.

    PubMed

    Inoue, T; Miyakoshi, S; Shimono, M

    2001-08-01

    The purpose of this study was to qualitate the penetration of the major components of 4-META/MMA-TBB adhesive resin (4-META resin) and to characterize their influence on the in vitro and in vivo wound healing of dental pulp tissues. Fresh 4-META resin was applied to rabbit mesentery; its components penetrated the mesentery to form three of layers, depending on the amounts of monomer components in the tissue. The superficial layer was a soft-tissue hybrid layer (STHL), the intermediate layer contained small particles of polymerized 4-META resin, while the deepest layer contained unpolymerized monomer components including MMA and butanol, which were detected by gas chromatography (GC). To characterize the in vivo effects of the deepest layer, we immersed the pulp tissue in MMA or in 5% 4-META/MMA and autotransplanted it to placement beneath a rabbit kidney capsule. The MMA-immersed pulp was positive for osteocalcin and presented osteodentin formation at 7 days, as did the untreated control pulp tissue. In contrast, the 5% 4-META/MMA-immersed pulp collapsed into the cell-deficient fibrous connective tissue, with slight calcification by 7 days and less osteodentin formation at 14 days. Analysis of these data suggests that MMA does not inhibit osteogenic activity of pulp tissue, while 5% 4-META/MMA does inhibit osteogenic activity to some extent.

  14. Design strategies and applications of tissue bioadhesives.

    PubMed

    Mehdizadeh, Mohammadreza; Yang, Jian

    2013-03-01

    In the past two decades tissue adhesives and sealants have revolutionized bleeding control and wound healing. This paper focuses on existing tissue adhesive design, their structure, functioning mechanism, and their pros and cons in wound management. It also includes the latest advances in the development of new tissue adhesives as well as the emerging applications in regenerative medicine. We expect that this paper will provide insightful discussion on tissue bioadhesive design and lead to innovations for the development of the next generation of tissue bioadhesives and their related biomedical applications. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Adhesive capabilities of Staphylococcus aureus and Pseudomonas aeruginosa isolated from tears of HIV/AIDS patients to soft contact lenses.

    PubMed

    Ajayi, B O; Kio, F E; Otajevwo, F D

    2012-01-01

    Fifty conjunctival swab samples collected from ELISA confirmed HIV/AIDS seropositive patients who were referred to the HIV/AIDS laboratories of the University of Benin Teaching Hospital and Central Hospital both based in Benin City, Nigeria were aseptically cultured on appropriate media by standard methods. The resulting isolates/strains, after identification by standard methods, were tested for their ability to adhere to two hydrophobic non-ionic daily wear silicone hydrogel soft contact lenses (i.e. lotrafilcon B, WC 33% and polymacon, WC 38%) as well as to two hydrophilic ionic conventional extended wear silicone hydrogel soft contact lenses (i.e. methafilcon A, WC 55% and omafilcon A, WC 60%) by the adhesiveness/slime production modified vortex/Robin device method. Evidence of adhesiveness/slime production was indicated by presence of a visible stained film lining the surface of the contact lens which was measured and recorded as strong or weak according to the density of the adhered bacterial film. Fourteen (28.0%) Staphylococcus aureus strains and 10 (20.0%) Pseudomonas aeruginosa strains were obtained among other organisms. Staphylococcus aureus strains adhered in decreasing order to lotrafilcon B (55.4 ± 4.7), polymacon (46.4 ± 8.4), methfilcon A (46.4 ± 8.4) and omafilcon A (25.0 ± 6.4) with no significant difference in adhesive strengths of individual strains (P > 0.05). Pseudomonas aeruginosa strains also recorded decreasing adhesive strengths to lotrafilcon B (37.5 ± 8.2), polymacon (28.6 ± 6.3), methafilcon A (26.8 ± 5.5) and omafilcon A (23.2 ± 5.5) also with no significant difference in adhesive strengths of individual strains (P > 0.05). Attachment strengths of Staph. aureus strains to all four contact lenses were higher than those of Pseudomonas aeruginosa strains. Both organisms adhered most to hydrophobic lotrafilcon B and least to hydrophilic omafilcon A. This invitro adhesion studies revealed that daily wear silicone hydrogel low water content, non-ionic contact lenses are more prone to bacterial adhesion than the conventional extended wear hydrogel high water content, ionic contact lenses and hence, there is more risk of microbial adhesion to the former compared to the latter. Other implications are highlighted.

  16. Adhesive Capabilities of Staphylococcus Aureus and Pseudomonas Aeruginosa Isolated from Tears of HIV/AIDS Patients to Soft Contact Lenses

    PubMed Central

    B. O., Ajayi; F.E., Kio; F.D., Otajevwo

    2012-01-01

    Fifty conjunctival swab samples collected from ELISA confirmed HIV/AIDS seropositive patients who were referred to the HIV/AIDS laboratories of the University of Benin Teaching Hospital and Central Hospital both based in Benin City, Nigeria were aseptically cultured on appropriate media by standard methods. The resulting isolates/strains, after identification by standard methods, were tested for their ability to adhere to two hydrophobic non-ionic daily wear silicone hydrogel soft contact lenses (i.e. lotrafilcon B, WC 33% and polymacon, WC 38%) as well as to two hydrophilic ionic conventional extended wear silicone hydrogel soft contact lenses (i.e. methafilcon A, WC 55% and omafilcon A, WC 60%) by the adhesiveness/slime production modified vortex/Robin device method. Evidence of adhesiveness/slime production was indicated by presence of a visible stained film lining the surface of the contact lens which was measured and recorded as strong or weak according to the density of the adhered bacterial film. Fourteen (28.0%) Staphylococcus aureus strains and 10 (20.0%) Pseudomonas aeruginosa strains were obtained among other organisms. Staphylococcus aureus strains adhered in decreasing order to lotrafilcon B (55.4 ± 4.7), polymacon (46.4 ± 8.4), methfilcon A (46.4 ± 8.4) and omafilcon A (25.0 ± 6.4) with no significant difference in adhesive strengths of individual strains (P > 0.05). Pseudomonas aeruginosa strains also recorded decreasing adhesive strengths to lotrafilcon B (37.5 ± 8.2), polymacon (28.6 ± 6.3), methafilcon A (26.8 ± 5.5) and omafilcon A (23.2 ± 5.5) also with no significant difference in adhesive strengths of individual strains (P > 0.05). Attachment strengths of Staph. aureus strains to all four contact lenses were higher than those of Pseudomonas aeruginosa strains. Both organisms adhered most to hydrophobic lotrafilcon B and least to hydrophilic omafilcon A. This invitro adhesion studies revealed that daily wear silicone hydrogel low water content, non-ionic contact lenses are more prone to bacterial adhesion than the conventional extended wear hydrogel high water content, ionic contact lenses and hence, there is more risk of microbial adhesion to the former compared to the latter. Other implications are highlighted. PMID:22980120

  17. General Information about Childhood Soft Tissue Sarcoma

    MedlinePlus

    ... Soft Tissue Sarcoma Treatment (PDQ®)–Patient Version General Information About Childhood Soft Tissue Sarcoma Go to Health ... the PDQ Pediatric Treatment Editorial Board . Clinical Trial Information A clinical trial is a study to answer ...

  18. General Information about Adult Soft Tissue Sarcoma

    MedlinePlus

    ... Soft Tissue Sarcoma Treatment (PDQ®)–Patient Version General Information About Adult Soft Tissue Sarcoma Go to Health ... the PDQ Adult Treatment Editorial Board . Clinical Trial Information A clinical trial is a study to answer ...

  19. Past matrix stiffness primes epithelial cells and regulates their future collective migration through a mechanical memory.

    PubMed

    Nasrollahi, Samila; Walter, Christopher; Loza, Andrew J; Schimizzi, Gregory V; Longmore, Gregory D; Pathak, Amit

    2017-11-01

    During morphogenesis and cancer metastasis, grouped cells migrate through tissues of dissimilar stiffness. Although the influence of matrix stiffness on cellular mechanosensitivity and motility are well-recognized, it remains unknown whether these matrix-dependent cellular features persist after cells move to a new microenvironment. Here, we interrogate whether priming of epithelial cells by a given matrix stiffness influences their future collective migration on a different matrix - a property we refer to as the 'mechanical memory' of migratory cells. To prime cells on a defined matrix and track their collective migration onto an adjoining secondary matrix of dissimilar stiffness, we develop a modular polyacrylamide substrate through step-by-step polymerization of different PA compositions. We report that epithelial cells primed on a stiff matrix migrate faster, display higher actomyosin expression, form larger focal adhesions, and retain nuclear YAP even after arriving onto a soft secondary matrix, as compared to their control behavior on a homogeneously soft matrix. Priming on a soft ECM causes a reverse effect. The depletion of YAP dramatically reduces this memory-dependent migration. Our results present a previously unidentified regulation of mechanosensitive collective cell migration by past matrix stiffness, in which mechanical memory depends on YAP activity. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. [Reconstruction of facial soft tissue defects with pedicled expanded flaps].

    PubMed

    Yangqun, Li; Yong, Tang; Wen, Chen; Zhe, Yang; Muxin, Zhao; Lisi, Xu; Chunmei, Hu; Yuanyuan, Liu; Ning, Ma; Jun, Feng; Weixin, Wang

    2014-09-01

    To investigate the application of pedicled expanded flaps for the reconstruction of facial soft tissue defects. The expanded skin flaps, pedicled with orbicularis oculi muscle, submental artery, the branch of facial artery, superficial temporal artery, interior upper arm artery, had similar texture and color as facial soft tissue. The pedicled expanded flaps have repaired the facial soft tissue defects. Between Jan. 2003 to Dec. 2013, 157 cases with facial soft tissue defects were reconstructed by pedicled expanded flaps. Epidermal necrosis happened at the distal end of 8 expanded flaps, pedicled with interior upper arm artery(4 cases), orbicularis oculi muscle(3 cases) and submental artery(1 case), which healed spontaneously after dressing. All the other flaps survived completely with similar color and inconspicuous scar. 112 cases were followed up for 8 months to 8 years. Satisfactory results were achieved in 75 cases. 37 cases with hypertrophic scar at incisions need secondary operation. Island pedicled expanded flap with similar texture and color as facial soft tissue is suitable for facial soft tissue defects. The facial extra-incision and large dog-ear deformity could be avoided.

  1. Differential diagnosis between benign and malignant soft tissue tumors utilizing ultrasound parameters.

    PubMed

    Morii, Takeshi; Kishino, Tomonori; Shimamori, Naoko; Motohashi, Mitsue; Ohnishi, Hiroaki; Honya, Keita; Aoyagi, Takayuki; Tajima, Takashi; Ichimura, Shoichi

    2018-01-01

    Preoperative discrimination between benign and malignant soft tissue tumors is critical for the prevention of excess application of magnetic resonance imaging and biopsy as well as unplanned resection. Although ultrasound, including power Doppler imaging, is an easy, noninvasive, and cost-effective modality for screening soft tissue tumors, few studies have investigated reliable discrimination between benign and malignant soft tissue tumors. To establish a modality for discrimination between benign and malignant soft tissue tumors using ultrasound, we extracted the significant risk factors for malignancy based on ultrasound information from 40 malignant and 56 benign pathologically diagnosed soft tissue tumors and established a scoring system based on these risk factors. The maximum size, tumor margin, and vascularity evaluated using ultrasound were extracted as significant risk factors. Using the odds ratio from a multivariate regression model, a scoring system was established. Receiver operating characteristic analyses revealed a high area under the curve value (0.85), confirming the accuracy of the scoring system. Ultrasound is a useful modality for establishing the differential diagnosis between benign and malignant soft tissue tumors.

  2. Treatment Concept for a Patient with a High Smile Line and Gingival Pigmentation: A Case Report.

    PubMed

    Zarone, Fernando; Leone, Renato; Ferrari, Marco; Sorrentino, Roberto

    Today, innovative restorative materials and techniques allow for minimally invasive prosthetic procedures, which are paramount to the preservation of hard and soft dental tissues. An integrated approach combining dental and esthetic medical therapies could be useful to improve the quality of life of patients, improving function, esthetics, and self-confidence. Oral esthetics depends on several variables, including tooth visibility and proportions as well as healthy gingival tissues. Proper integration between teeth and periodontal tissues plays an important role in esthetic success, which is mainly represented by an appealing smile. The present case report was aimed at describing the multidisciplinary treatment of a woman who was unsatisfied with the shape of her central incisors and the dark gingival pigmentation displayed by a high smile line. The patient was treated with minimally invasive combined periodontal, prosthetic, and esthetic medical techniques. The described multidisciplinary approach based on surgical gingival depigmentation, adhesive ceramic veneers, and selective botulinum toxin injection was effective in solving the undesired high smile line and achieving patient satisfaction.

  3. Childhood Soft Tissue Sarcoma Treatment (PDQ®)—Health Professional Version

    Cancer.gov

    Pediatric soft tissue sarcomas are a heterogenous group of malignant tumors that originate from primitive mesenchymal tissue and account for 7% of all childhood tumors. Get detailed information about clinical presentation, diagnosis, prognosis, and treatment of newly diagnosed and recurrent soft tissue sarcoma in this summary for clinicians.

  4. Application of hyaluronic acid/sodium alginate-based microparticles to prevent tissue adhesion in a rabbit model.

    PubMed

    Back, Ja Hoon; Cho, Wan Jin; Kim, Jun Ho; Park, Il Kyu; Kwon, Sung Won

    2016-04-01

    Postsurgical adhesion formation is a concern in every field of surgery. We evaluated the efficacy of hyaluronic acid/sodium alginate-based microparticle anti-adhesive agents (MP) for the prevention of postsurgical adhesion formation in a standardized rabbit model. To evaluate the anti-adhesion effect, a uterus-abdominal wall abrasion model was created in rabbits. On the surface of the injured uterus, an anti-adhesive agent, Interceed(®) or MP, was applied (positive control and study groups, respectively; n = 10 each). In another group of 10 animals, neither agent was applied (negative control group). The adhesion levels were graded 3 weeks after surgery. Acute and chronic toxicity was also evaluated. The grade of adhesion was significantly lower in the MP group than in the negative control and positive control groups. No evidence of acute or chronic toxicity induced by this material was found in blood and tissue analysis. MP shows potential as an effective novel type of resorbable biomaterial to reduce postoperative adhesion. The easy placement and handling of this material make the MP powder attractive as a tissue adhesion barrier.

  5. Anionic deep cavitands enable the adhesion of unmodified proteins at a membrane bilayer.

    PubMed

    Ghang, Yoo-Jin; Perez, Lizeth; Morgan, Melissa A; Si, Fang; Hamdy, Omar M; Beecher, Consuelo N; Larive, Cynthia K; Julian, Ryan R; Zhong, Wenwan; Cheng, Quan; Hooley, Richard J

    2014-12-28

    An anionic self-folding deep cavitand is capable of immobilizing unmodified proteins and enzymes at a supported lipid bilayer interface, providing a simple, soft bioreactive surface that allows enzymatic function under mild conditions. The adhesion is based on complementary charge interactions, and the hosts are capable of binding enzymes such as trypsin at the bilayer interface: the catalytic activity is retained upon adhesion, allowing selective reactions to be performed at the membrane surface.

  6. The Application of Skin Adhesive to Maintain Seal in Negative Pressure Wound Therapy.

    PubMed

    Karadsheh, Murad J; Nelson, Josh; Wilcox, Richard

    2015-09-01

    Optimal wound healing in negative pressure wound therapy (NPWT) depends on a properly sealed vacuum system. Anatomically difficult wounds disrupt the adhesive dressing, resulting in air leaks that impair the integrity of this system. Several techniques have been used in previous reports to prevent air leaks, including the addition of skin adhesives (eg, Skin-Prep [Smith and Nephew, St. Petersburg, FL] or compound tincture of benzoin), hydrocolloid dressings, silicone, and stoma paste. The purpose of this case report is to demonstrate the effectiveness of using a cyanoacrylate tissue adhesive, dermaFLEX (FLEXCon, Spencer, MA), in maintaining an airtight, durable seal in NPWT. The authors present a patient with a difficult to manage anogenital wound where efforts to maintain an airtight seal in NPWT proved difficult. It was decided during the course of treatment to use the cyanoacrylate tissue adhesive to create an airtight, durable seal. The tissue adhesive was applied circumferentially to the skin surrounding the wound edge. After placement of vacuum-assisted closure foam over the wound, the adhesive dressing was applied with its edges overlapping the skin area where the tissue adhesive was applied. The size of the wound was visibly reduced at each dressing change. An airtight seal was consistently maintained for 3 days at a time, surviving the difficult environment of the wound and maximizing the life of each adhesive dressing. For wounds in anatomically challenging locations, the use of the tissue adhesive appears to be a safe and viable option in creating a durable seal in NPWT.

  7. Alisertib in Treating Patients With Advanced or Metastatic Sarcoma

    ClinicalTrials.gov

    2017-11-29

    Myxofibrosarcoma; Recurrent Adult Soft Tissue Sarcoma; Recurrent Leiomyosarcoma; Recurrent Liposarcoma; Recurrent Malignant Peripheral Nerve Sheath Tumor; Recurrent Undifferentiated Pleomorphic Sarcoma; Stage III Soft Tissue Sarcoma AJCC v7; Stage IV Soft Tissue Sarcoma AJCC v7

  8. Large Osteoarthritic Cyst Presenting as Soft Tissue Tumour – A Case Report

    PubMed Central

    Kosuge, DD; Park, DH; Cannon, SR; Briggs, TW; Pollock, RC; Skinner, JA

    2007-01-01

    Large osteoarthritic cysts can sometimes be difficult to distinguish from primary osseous and soft tissue tumours. We present such a case involving a cyst arising from the hip joint and eroding the acetabulum which presented as a soft tissue malignancy referred to a tertiary bone and soft tissue tumour centre. We discuss the diagnostic problems it may pose, and present a literature review of the subject. PMID:17535605

  9. [Soft tissue melanoma: a clinical case].

    PubMed

    Frikh, Rachid; Oumakhir, Siham; Chahdi, Hafsa; Oukabli, Mohammed; Albouzidi, Abderrahmane; Baba, Noureddine; Hjira, Naoufal; Boui, Mohammed

    2017-01-01

    Soft tissue melanoma was first described by Enzinger in 1965 under the name of clear cell sarcoma. In 1983, Chung and Enzinger renamed it soft tissue melanoma due to its immunohistochemical similarities with melanoma. We here report the case of a 22-year old young man with this rare type of melanoma, presenting with molluscoid lesion on his ankle without any clinical sign of malignancy. Histology examination confirmed the diagnosis of soft tissue melanoma.

  10. Soft-Tissue Injuries Associated With High-Energy Extremity Trauma: Principles of Management.

    PubMed

    Norris; Kellam

    1997-01-01

    The management of high-energy extremity trauma has evolved over the past several decades, and appropriate treatment of associated soft-tissue injuries has proved to be an important factor in achieving a satisfactory outcome. Early evaluation of the severely injured extremity is crucial. Severe closed injuries require serial observation of the soft tissues and early skeletal stabilization. Open injuries require early aggressive debridement of the soft tissues followed by skeletal stabilization. Temporary wound dressings should remain in place until definitive soft-tissue coverage has been obtained. Definitive soft-tissue closure will be expedited by serial debridements performed every 48 to 72 hours in a sterile environment. Skeletal union is facilitated by early bone grafting and/or modification of the stabilizing device. Aggressive rehabilitation, includ-ing early social reintegration, are crucial for a good functional outcome. Adherence to protocols is especially beneficial in the management of salvageable severely injured extremities.

  11. MAPs/bFGF-PLGA microsphere composite-coated titanium surfaces promote increased adhesion and proliferation of fibroblasts.

    PubMed

    Wang, Zhongshan; Wu, Guofeng; Bai, Shizhu; Feng, Zhihong; Dong, Yan; Zhou, Jian; Qin, Haiyan; Zhao, Yimin

    2014-06-01

    Infection and epithelial downgrowth are two major problems with maxillofacial transcutaneous implants, and both are mainly due to lack of stable closure of soft tissues at transcutaneous sites. Fibroblasts have been shown to play a key role in the formation of biological seals. In this work, titanium (Ti) model surfaces were coated with mussel adhesive proteins (MAPs) utilizing its unique adhesion ability on diverse inorganic and organic surfaces in wet environments. Prepared basic fibroblast growth factor (bFGF)-poly(lactic-co-glycolic acid) (PLGA) microspheres can be easily synthesized and combined onto MAPs-coated Ti surfaces, due to the negative surface charges of microspheres in aqueous solution, which is in contrast to the positive charges of MAPs. Titanium model surfaces were divided into three groups. Group A: MAPs/bFGF-PLGA microspheres composite-coated Ti surfaces. Group B: MAPs-coated Ti surfaces. Group C: uncoated Ti surfaces. The effects of coated Ti surfaces on adhesion of fibroblasts, cytoskeletal organization, proliferation, and extracellular matrix (ECM)-related gene expressions were examined. The results revealed increased adhesion (P < 0.05), enhanced actin cytoskeletal organization, and up-regulated ECM-related gene expressions in groups A and B compared with group C. Increased proliferation of fibroblasts during five days of incubation was observed in group A compared with groups B and C (P < 0.05). Collectively, the results from this in vitro study demonstrated that MAPs/bFGF-PLGA microspheres composite-coated Ti surfaces had the ability to increase fibroblast functionality. In addition, MAPs/bFGF-PLGA microsphere composite-coated Ti surfaces should be studied further as a method of promoting formation of stable biological seals around transcutaneous sites.

  12. Dynamic soft tissue deformation estimation based on energy analysis

    NASA Astrophysics Data System (ADS)

    Gao, Dedong; Lei, Yong; Yao, Bin

    2016-10-01

    The needle placement accuracy of millimeters is required in many needle-based surgeries. The tissue deformation, especially that occurring on the surface of organ tissue, affects the needle-targeting accuracy of both manual and robotic needle insertions. It is necessary to understand the mechanism of tissue deformation during needle insertion into soft tissue. In this paper, soft tissue surface deformation is investigated on the basis of continuum mechanics, where a geometry model is presented to quantitatively approximate the volume of tissue deformation. The energy-based method is presented to the dynamic process of needle insertion into soft tissue based on continuum mechanics, and the volume of the cone is exploited to quantitatively approximate the deformation on the surface of soft tissue. The external work is converted into potential, kinetic, dissipated, and strain energies during the dynamic rigid needle-tissue interactive process. The needle insertion experimental setup, consisting of a linear actuator, force sensor, needle, tissue container, and a light, is constructed while an image-based method for measuring the depth and radius of the soft tissue surface deformations is introduced to obtain the experimental data. The relationship between the changed volume of tissue deformation and the insertion parameters is created based on the law of conservation of energy, with the volume of tissue deformation having been obtained using image-based measurements. The experiments are performed on phantom specimens, and an energy-based analytical fitted model is presented to estimate the volume of tissue deformation. The experimental results show that the energy-based analytical fitted model can predict the volume of soft tissue deformation, and the root mean squared errors of the fitting model and experimental data are 0.61 and 0.25 at the velocities 2.50 mm/s and 5.00 mm/s. The estimating parameters of the soft tissue surface deformations are proven to be useful for compensating the needle-targeting error in the rigid needle insertion procedure, especially for percutaneous needle insertion into organs.

  13. Effect of antipronation foot orthosis geometry on compression of heel and arch soft tissues.

    PubMed

    Sweeney, Declan; Nester, Christopher; Preece, Stephen; Mickle, Karen

    2015-01-01

    This study aimed to understand how systematic changes in arch height and two designs of heel wedging affect soft tissues under the foot. Soft tissue thickness under the heel and navicular was measured using ultrasound. Heel pad thickness was measured when subjects were standing on a flat surface and standing on an orthosis with 4 and 8 degree extrinsic wedges and 4 mm and 8 mm intrinsic wedges (n = 27). Arch soft tissue thickness was measured when subjects were standing and when standing on an orthosis with -6 mm, standard, and +6 mm increments in arch height (n = 25). Extrinsic and intrinsic heel wedges significantly increased soft tissue thickness under the heel compared with no orthosis. The 4 and 8 degree extrinsic wedges increased tissue thickness by 28% and 27.6%, respectively, while the 4 mm and 8 mm intrinsic wedges increased thickness by 23% and 14.6%, respectively. Orthotic arch height significantly affected arch soft tissue thickness. Compared with the no orthosis condition, the -6 mm, standard, and +6 mm arch heights decreased arch tissue thickness by 9%, 10%, and 11.8%, respectively. This study demonstrates that change in orthotic geometry creates different plantar soft tissue responses that we expect to affect transmission of force to underlying foot bones.

  14. Cell-based regenerative approaches to the treatment of oral soft tissue defects.

    PubMed

    Bates, Damien; Kampa, Peggy

    2013-01-01

    Oral soft tissue plays an important role in the structure and function of the oral cavity by protecting against exogenous substances, pathogens, and mechanical stresses. Repair of oral soft tissue defects that arise as a result of disease, trauma, or congenital abnormalities is often accomplished via transplantation or transfer of autologous mucosal tissue. However, this method of treatment can be complicated by the relatively small amount of autologous mucosal tissue that is available, as well as by the morbidity that may be associated with the donor site and patient reluctance to have oral (eg, palatal) surgery. To circumvent these problems, clinicians have turned to the fields of tissue engineering and regenerative medicine to develop acellular and cellular strategies for regenerating oral soft tissue. This review focuses on the efficacy and safety of cell-based investigational approaches to the regeneration of oral soft tissue.

  15. Finite element dynamic analysis of soft tissues using state-space model.

    PubMed

    Iorga, Lucian N; Shan, Baoxiang; Pelegri, Assimina A

    2009-04-01

    A finite element (FE) model is employed to investigate the dynamic response of soft tissues under external excitations, particularly corresponding to the case of harmonic motion imaging. A solid 3D mixed 'u-p' element S8P0 is implemented to capture the near-incompressibility inherent in soft tissues. Two important aspects in structural modelling of these tissues are studied; these are the influence of viscous damping on the dynamic response and, following FE-modelling, a developed state-space formulation that valuates the efficiency of several order reduction methods. It is illustrated that the order of the mathematical model can be significantly reduced, while preserving the accuracy of the observed system dynamics. Thus, the reduced-order state-space representation of soft tissues for general dynamic analysis significantly reduces the computational cost and provides a unitary framework for the 'forward' simulation and 'inverse' estimation of soft tissues. Moreover, the results suggest that damping in soft-tissue is significant, effectively cancelling the contribution of all but the first few vibration modes.

  16. Soft-tissue reactions following irradiation of primary brain and pituitary tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baglan, R.J.; Marks, J.E.

    1981-04-01

    One hundred and ninety-nine patients who received radiation therapy for a primary brain or pituitary tumor were studied for radiation-induced soft-tissue reactions of the cranium, scalp, ears and jaw. The frequency of these reactions was studied as a function of: the radiation dose 5 mm below the skin surface, dose distribution, field size and fraction size. Forty percent of patients had complete and permanent epilation, while 21% had some other soft-tissue complication, including: scalp swelling-6%, external otitis-6%, otitis media-5%, ear swelling-4%, etc. The frequency of soft-tissue reactions correlates directly with the radiation dose at 5 mm below the skin surface.more » Patients treated with small portals (<70 cm/sup 2/) had few soft-tissue reactions. The dose to superficial tissues, and hence the frequency of soft-tissue reactions can be reduced by: (1) using high-energy megavoltage beams; (2) using equal loading of beams; and (3) possibly avoiding the use of electron beams.« less

  17. Do uniform tangential interfacial stresses enhance adhesion?

    NASA Astrophysics Data System (ADS)

    Menga, Nicola; Carbone, Giuseppe; Dini, Daniele

    2018-03-01

    We present theoretical arguments, based on linear elasticity and thermodynamics, to show that interfacial tangential stresses in sliding adhesive soft contacts may lead to a significant increase of the effective energy of adhesion. A sizable expansion of the contact area is predicted in conditions corresponding to such scenario. These results are easily explained and are valid under the assumptions that: (i) sliding at the interface does not lead to any loss of adhesive interaction and (ii) spatial fluctuations of frictional stresses can be considered negligible. Our results are seemingly supported by existing experiments, and show that frictional stresses may lead to an increase of the effective energy of adhesion depending on which conditions are established at the interface of contacting bodies in the presence of adhesive forces.

  18. The use of acellular dermal matrix membrane for vertical soft tissue augmentation during submerged implant placement: a case series.

    PubMed

    Puisys, Algirdas; Vindasiute, Egle; Linkevciene, Laura; Linkevicius, Tomas

    2015-04-01

    To evaluate the efficiency of acellular dermal matrix membrane to augment vertical peri-implant soft tissue thickness during submerged implant placement. Forty acellular dermal matrix-derived allogenic membranes (AlloDerm, BioHorizons, Birmingham, AL, USA) and 42 laser-modified surface internal hex implants (BioHorizons Tapered Laser Lok, Birmingham, AL, USA) were placed in submerged approach in 40 patients (15 males and 25 females, mean age 42.5 ± 1.7) with a thin vertical soft tissue thickness of 2 mm or less. After 3 months, healing abutments were connected to implants, and the augmented soft tissue thickness was measured with periodontal probe. The gain in vertical soft tissue volume was calculated. Mann-Whitney U-test was applied and significance was set to 0.05. All 40 allografts healed successfully. Thin soft tissue before augmentation had an average thickness of 1.54 ± 0.51 mm SD (range, 0.5-2.0 mm, median 1.75 mm), and after soft tissue augmentation with acellular dermal matrix, thickness increased to 3.75 ± 0.54 mm SD (range, 3.0-5.0 mm, median 4.0 mm) at 3 months after placement. This difference between medians was found to be statistically significant (P < 0.001). Mean increase in soft tissue thickness was 2.21 ± 0.85 mm SD (range, 1.0-4.5 mm, median 2.0 mm). It can be concluded that acellular dermal matrix membrane can be successfully used for vertical soft tissue augmentation. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Soft tissue molding technique in cleft lip and palate patient using laser surgery in combination with orthodontic appliance: A case report.

    PubMed

    Theerasopon, Pornpat; Wangsrimongkol, Tasanee; Sattayut, Sajee

    2017-03-31

    Although surgical treatment protocols for cleft lip and palate patients have been established, many patients still have some soft tissue defects after complete healing from surgical interventions. These are excess soft tissue, high attached fraena and firmed tethering scares. These soft tissue defects resulted shallowing of vestibule, restricted tooth movement, compromised periodontal health and trended to limit the maxillary growth. The aim of this case report was to present a method of correcting soft tissue defects after conventional surgery in cleft lip and palate patient by using combined laser surgery and orthodontic appliance. A bilateral cleft lip and palate patient with a clinical problem of shallow upper anterior vestibule after alveolar bone graft received a vestibular extension by using CO 2 laser with ablation and vaporization techniques at 4 W and continuous wave. A customized orthodontic appliance, called a buccal shield, was placed immediately after surgery and retained for 1 month to 3 months until complete soft tissue healing. The procedures were performed 2 episodes. Both interventions used the same CO 2 laser procedure. The first treatment resulted in partial re-attachment of soft tissue at surgical area. The second laser operation with the proper design of buccal shield providing passive contact with more extended flange resulting in a favorable outcome from 1 year follow up. Then the corrective orthodontic treatment could be continued effectively. The CO 2 laser surgery was a proper treatment for correcting soft tissue defects and the design of buccal shield was a key for success in molding surgical soft tissue.

  20. Non-interventional 1-year follow-up study of peri-implant soft tissues following previous soft tissue augmentation and crown insertion in single-tooth gaps.

    PubMed

    Huber, Samuel; Zeltner, Marco; Hämmerle, Christoph H F; Jung, Ronald E; Thoma, Daniel S

    2018-04-01

    To assess peri-implant soft tissue dimensions at implant sites, previously augmented with a collagen matrix (VCMX) or an autogenous subepithelial connective tissue graft (SCTG), between crown insertion and 1 year. Twenty patients with single-tooth implants received soft tissue augmentation prior to abutment connection randomly using VCMX or SCTG. Following abutment connection 3 months later, final reconstructions were fabricated and inserted (baseline). Patients were recalled at 6 months (6M) and at 1 year (FU-1). Measurements included clinical data, soft tissue thickness, volumetric outcomes and patient-reported outcome measures (PROMs). The buccal soft tissue thickness showed a median decrease of -0.5 mm (-1.0;0.3) (VCMX) and 0.0 mm (-0.5;1.0) (SCTG) (p = .243) up to FU-1. The soft tissue volume demonstrated a median decrease between BL and FU-1 of -0.1 mm (-0.2;0.0) (p = .301) for VCMX and a significant decrease of -0.2 mm (-0.4; -0.1) (p = .002) for SCTG, respectively. Intergroup comparisons did not reveal any significant differences between the groups for peri-implant soft tissue dimensions and changes up to FU-1 (p > .05). PROMs did not show any significant changes over time nor differences between the groups. Between crown insertion and 1 year, the buccal peri-implant soft tissue dimensions remained stable without relevant differences between sites that had previously been grafted with VCMX or SCTG. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Factors influencing soft tissue profile changes following orthodontic treatment in patients with Class II Division 1 malocclusion.

    PubMed

    Maetevorakul, Suhatcha; Viteporn, Smorntree

    2016-01-01

    Several studies have shown soft tissue profile changes after orthodontic treatment in Class II Division 1 patients. However, a few studies have described factors influencing the soft tissue changes. The purpose of this study was to investigate the factors influencing the soft tissue profile changes following orthodontic treatment in Class II Division 1 patients. The subjects comprised 104 Thai patients age 8-16 years who presented Class II Division 1 malocclusions and were treated with different orthodontic modalities comprising cervical headgear, Class II traction and extraction of the four first premolars. The profile changes were evaluated from the lateral cephalograms before and after treatment by means of the X-Y coordinate system. Significant soft tissue profile changes were evaluated by paired t test at a 0.05 significance level. The correlations among significant soft tissue changes and independent variables comprising treatment modality, age, sex, pretreatment skeletal, dental and soft tissue morphology were evaluated by stepwise multiple regression analysis at a 0.05 significance level. The multiple regression analysis indicated that different treatment modalities, age, sex, pretreatment skeletal, dental and soft tissue morphology were related to the profile changes. The predictive power of these variables on the soft tissue profile changes ranged from 9.9 to 40.3%. Prediction of the soft tissue profile changes following treatment of Class II Division 1 malocclusion from initial patient morphology, age, sex and types of treatment was complicated and required several variables to explain their variations. Upper lip change in horizontal direction could be found only at the stomion superius and was less predictable than those of the lower lip. Variations in upper lip retraction at the stomion superius were explained by types of treatment (R(2) = 0.099), whereas protrusion of the lower lip at the labrale inferius was correlated with initial inclination of the lower incisor (L1 to NB), jaw relation (ANB angle), lower lip thickness and sex (R(2) = 0.403). Prediction of chin protrusion at the soft tissue pogonion was also low predictable (R(2) = 0.190) depending upon sex, age and initial mandibular plane angle (SN-GoGn). Additionally, age and sex also had mainly effect on change of the soft tissue profile in the vertical direction.

  2. Orthodontic-periodontal interactions: Orthodontic extrusion in interdisciplinary regenerative treatments.

    PubMed

    Paolone, Maria Giacinta; Kaitsas, Roberto

    2018-06-01

    Orthodontics is a periodontal treatment. "Guided orthodontic regeneration" (GOR) procedures use orthodontic movements in perio-restorative patients. The GOR technique includes a guided orthodontic "soft tissue" regeneration (GOTR) and a guided orthodontic "bone" regeneration (GOBR) with a plastic soft tissue approach and a regenerating reality. The increased amount of soft tissue gained with orthodontic movement can be used for subsequent periodontal regenerative techniques. The increased amount of bone can as well improve primary implant stability and, eventually, simplify a GTR technique to regenerate soft tissues, to restore tooth with external resorption in aesthetic zone or to extract a tooth to create new hard-soft tissue for adjacent teeth. Copyright © 2018. Published by Elsevier Masson SAS.

  3. Histomorphometrical analysis following augmentation of infected extraction sites exhibiting severe bone loss and primarily closed by intrasocket reactive soft tissue.

    PubMed

    Mardinger, Ofer; Vered, Marilena; Chaushu, Gavriel; Nissan, Joseph

    2012-06-01

    Intrasocket reactive soft tissue can be used for primary closure during augmentation of infected extraction sites exhibiting severe bone loss prior to implant placement. The present study evaluated the histological characteristics of the initially used intrasocket reactive soft tissue, the overlying soft tissue, and the histomorphometry of the newly formed bone during implant placement. Thirty-six consecutive patients (43 sites) were included in the study. Extraction sites demonstrating extensive bone loss on preoperative periapical and panoramic radiographs served as inclusion criteria. Forty-three implants were inserted after a healing period of 6 months. Porous bovine xenograft bone mineral was used as a single bone substitute. The intrasocket reactive soft tissue was sutured over the grafting material to seal the coronal portion of the socket. Biopsies of the intrasocket reactive soft tissue at augmentation, healed mucosa, and bone cores at implant placement were retrieved and evaluated. The intrasocket reactive soft tissue demonstrated features compatible with granulation tissue and long junctional epithelium. The mucosal samples at implant placement demonstrated histopathological characteristics of keratinized mucosa with no residual elements of granulation tissue. Histomorphometrically, the mean composition of the bone cores was - vital bone 40 ± 19% (13.7-74.8%); bone substitute 25.7 ± 13% (0.6-51%); connective tissue 34.3 ± 15% (13.8-71.9%). Intrasocket reactive soft tissue used for primary closure following ridge augmentation is composed of granulation tissue and long junctional epithelium. At implant placement, clinical and histological results demonstrate its replacement by keratinized gingiva. The histomorphometrical results reveal considerable bone formation. Fresh extraction sites of hopeless teeth demonstrating chronic infection and severe bone loss may be grafted simultaneously with their removal. © 2010 Wiley Periodicals, Inc.

  4. Changes of the peri-implant soft tissue thickness after grafting with a collagen matrix.

    PubMed

    Zafiropoulos, Gregory-George; Deli, Giorgio; Hoffmann, Oliver; John, Gordon

    2016-01-01

    The aim of this study was to determine the treatment outcome of the use of a porcine monolayer collagen matrix (mCM) to increase soft-tissue volume as a part of implant site development. Implants were placed in single sites in 27 patients. In the test group, mCM was used for soft-tissue augmentation. No graft was placed in the control group. Soft-tissue thickness (STTh) was measured at the time of surgery (T0) and 6 months postoperatively (T1) at two sites (STTh 1, 1 mm below the gingival margin; STTh 2, 3 mm below the mucogingival margin). Significant increases ( P < 0.001) in STTh (STTh 1 = 1.06 mm, 117%; STTh 2 = 0.89 mm, 81%) were observed in the test group. Biopsy results showed angiogenesis and mature connective tissue covered by keratinized epithelium. Within the limitations of this study, it could be concluded that mCM leads to a significant increase of peri-implant soft-tissue thickness, with good histological integration and replacement by soft tissue and may serve as an alternative to connective tissue grafting.

  5. Comprehensive Review of Tissue Adhesives.

    PubMed

    Jenkins, Lauren E; Davis, Loretta S

    2018-06-19

    Cyanoacrylates, also known as tissue adhesives or skin glues, are commonly used as sealants for lacerations and incisions and have found utility in excisional and cosmetic surgeries in both outpatient and operating room settings. To review the surgical literature on the utilities, advantages, disadvantages, and special uses of cyanoacrylates applicable to dermatology. PubMed was reviewed for relevant articles related to cyanoacrylates and their use in skin closures. Articles unrelated to cutaneous closures were excluded. Tissue adhesives polymerize to a water resistant, pliable film after application to approximated wound edges and have antibacterial properties. Adhesives slowly slough off as the wound heals, typically after 5 days. Compared with 5-0 nonabsorbable suture, adhesives provide similar tensile strength and similar patient and surgeon satisfaction. Although slightly more expensive than sutures, tissue adhesives obviate the need for wound dressings and suture removal. They do not perform as well as sutures for wounds under higher tension or in the setting of moisture and inadequate hemostasis. Cyanoacrylates serve as a safe and effective suture alternative in appropriate dermatologic surgeries and procedures.

  6. Factors influencing on retro-odontoid soft-tissue thickness: analysis by magnetic resonance imaging.

    PubMed

    Tojo, Shinjiro; Kawakami, Reina; Yonenaga, Takenori; Hayashi, Daichi; Fukuda, Kunihiko

    2013-03-01

    A retrospective, consecutive case series. To analyze the relationship between retro-odontoid soft-tissue thickness and patients' age, sex, and degenerative changes of cervical spine and to investigate the effect these factors have on retro-odontoid soft-tissue thickness. Thickening of the soft tissue posterior to the odontoid process can form a retro-odontoid pseudotumor causing symptoms of spinal cord compression. Rheumatoid arthritis and long-term dialysis have been reported as possible causes for this. However, there have been reports of retro-odontoid pseudotumors without coexisting diseases. Findings from a total of 503 cases of cervical spine magnetic resonance images were reviewed, and retro-odontoid soft-tissue thickness was measured. The values were matched for age, sex, presence of degenerative changes, rheumatoid arthritis, and dialysis and were analyzed for significance. Retro-odontoid soft tissue thickened with age, and this was also seen in male patients and patients with degenerative changes. Significant increase in thickness was also observed in patients undergoing dialysis and further increased with prolonged dialysis. There was no significant association with presence of rheumatoid arthritis. There is association between age, sex, degenerative cervical spine changes, and dialysis with retro-odontoid soft-tissue thickness. With dialysis, retro-odontoid soft-tissue thickness increases with increasing duration. Thus, reviewing magnetic resonance image from daily practice indicates that cervical spine degeneration is associated with the development of retro-odontoid pseudotumors.

  7. Facial laceration at caesarean section: experience with tissue adhesive.

    PubMed

    Saraf, Sanjay

    2009-01-01

    The fetal laceration is one of the most commonly identified injuries at the caesarean delivery. The incidence in the literature has been reported to be as high as 3%. The management of such injuries has remained a perplexing problem for both the physician and the parents. We present a case of a newborn who accidentally sustained laceration over the face during a caesarean delivery. A review of the literature and management of lacerations with tissue adhesives has been presented. The laceration was successfully managed with tissue adhesive alone with good aesthetic outcome. Topical 2-octylcyanoacrylate tissue adhesives can be an effective alternative therapy for traditional devices for closing simple low-tension lacerations.

  8. [Inconformity between soft tissue defect and bony defect in incomplete cleft palate].

    PubMed

    Zhou, Xia; Ma, Lian

    2014-12-01

    To evaluate the inconformity between soft tissue defect and bony defect by observing the cleft extent of palate with complete secondary palate bony cleft in incomplete cleft palate patient. The patients with incomplete cleft palate treated in Hospital of Stomatology Peking University from July 2012 to June 2013 were reviewed, of which 75 cases with complete secondary palate bony cleft were selected in this study. The CT scan and intraoral photograph were taken before operation. The patients were classified as four types according to the extent of soft tissue defect. Type 1: soft tissue defect reached incisive foremen region, Type 2 was hard and soft cleft palate, Type 3 soft cleft palate and Type 4 submucous cleft palate. Type 1 was defined as conformity group (CG). The other three types were defined as inconformity group (ICG) and divided into three subgroups (ICG-I), (ICG-II) and (ICG-III). Fifty-seven patients were in ICG group, and the rate of inconformity was 76% (57/75). The percentage of ICG-I, ICG-II and ICG-III was 47% (27/57), 23% (13/57) and 30% (17/57), respevtively. There are different types of soft tissue deformity with complete secondary palate bony cleft. The inconformity between soft tissue and hard tissue defect exits in 3/4 of isolated cleft palate patients.

  9. Active metal oxides and polymer hybrids as biomaterials

    NASA Astrophysics Data System (ADS)

    Jarrell, John D.

    Bone anchored prosthetic attachments, like other percutaneous devices, suffer from poor soft tissue integration, seen as chronic inflammation, infection, epithelial downgrowth and regression. We looked at the use of metal oxides as bioactive agents that elicit different bioresponses, ranging from cell attachment, tissue integration and reduction of inflammation to modulation of cell proliferation, morphology and microbe killing. This study presents a novel method for creating titanium oxide and polydimethylsiloxane (PDMS) hybrid coated microplates for high throughput biological, bacterial and photocatalytic screening that overcomes several limitations of using bulk metal samples. Titanium oxide coatings were doped with silver, zinc, vanadium, aluminum, calcium and phosphorous, while PDMS was doped with titanium, vanadium and silver and subjected to hydrothermal heat treatment to determine the influence of chemistry and crystallinity on the viability, proliferation and adhesion of human fibroblasts, keratinocytes and Hela cells. Also explored was the influence of Ag and Zn doping on E. coli proliferation. We determined how titanium concentration in hybrids and silver doping influenced the photocatalytic degradation of methylene blue by coatings. A combined sub/percutaneous, polyurethane device was developed and implanted into the backs of CD hairless rats to investigate how optimized coatings influenced soft tissue integration in vivo. We demonstrate that the bioresponse of cells to coatings is controlled by elemental doping (V & Ag) and that planktonic bacterial growth was greatly reduced or stopped by Ag, but not Zn doping. Hydrothermal heat treatments (65 °C and 121 °C) did not greatly influence cellular bioresponse to coatings. We discovered a range of temperature resistant (up to 400 °C), solid state dispersions with enhanced ability to block full spectrum photon transmission and degrade methylene using medical x-rays, UV, visible and infrared photons. We show that silver doping improved the photoactivity of oxide coatings, but hindered activity of a specific hybrid. Doped titanium oxide and polymer hybrid coatings have potential for improving soft tissue integration of medical implants and wound healing by modulating cell proliferation, attachment, inflammation and providing controlled delivery of bioactive and antimicrobial compounds and photon induced electro-chemical activity.

  10. Design of Xylose-Based Semisynthetic Polyurethane Tissue Adhesives with Enhanced Bioactivity Properties.

    PubMed

    Balcioglu, Sevgi; Parlakpinar, Hakan; Vardi, Nigar; Denkbas, Emir Baki; Karaaslan, Merve Goksin; Gulgen, Selam; Taslidere, Elif; Koytepe, Suleyman; Ates, Burhan

    2016-02-01

    Developing biocompatible tissue adhesives with high adhesion properties is a highly desired goal of the tissue engineering due to adverse effects of the sutures. Therefore, our work involves synthesis, characterization, adhesion properties, protein adsorption, in vitro biodegradation, in vitro and in vivo biocompatibility properties of xylose-based semisynthetic polyurethane (NPU-PEG-X) bioadhesives. Xylose-based semisynthetic polyurethanes were developed by the reaction among 4,4'-methylenebis(cyclohexyl isocyanate) (MCI), xylose and polyethylene glycol 200 (PEG). Synthesized polyurethanes (PUs) showed good thermal stability and high adhesion strength. The highest values in adhesion strength were measured as 415.0 ± 48.8 and 94.0 ± 2.8 kPa for aluminum substrate and muscle tissue in 15% xylose containing PUs (NPU-PEG-X-15%), respectively. The biodegradation of NPU-PEG-X-15% was also determined as 19.96 ± 1.04% after 8 weeks of incubation. Relative cell viability of xylose containing PU was above 86%. Moreover, 10% xylose containing NPU-PEG-X (NPU-PEG-X-10%) sample has favorable tissue response, and inflammatory reaction between 1 and 6 weeks implantation period. With high adhesiveness and biocompatibility properties, NPU-PEG-X can be used in the medical field as supporting materials for preventing the fluid leakage after abdominal surgery or wound closure.

  11. Noncontact measurement of elasticity for the detection of soft-tissue tumors using phase-sensitive optical coherence tomography combined with a focused air-puff system.

    PubMed

    Wang, Shang; Li, Jiasong; Manapuram, Ravi Kiran; Menodiado, Floredes M; Ingram, Davis R; Twa, Michael D; Lazar, Alexander J; Lev, Dina C; Pollock, Raphael E; Larin, Kirill V

    2012-12-15

    We report on an optical noncontact method for the detection of soft-tissue tumors based on the measurement of their elasticity. A focused air-puff system is used to excite surface waves (SWs) on soft tissues with transient static pressure. A high-speed phase-sensitive optical coherence tomography system is used to measure the SWs as they propagate from the point of excitation. To evaluate the stiffness of soft tissues, the Young's modulus is quantified based on the group velocity of SWs. Pilot experiments were performed on ex vivo human myxoma and normal fat. Results demonstrate the feasibility of the proposed method to measure elasticity and differentiate soft-tissue tumors from normal tissues.

  12. Comparison of synthetic glues and 10-0 nylon in rabbit lamellar keratoplasty.

    PubMed

    Cho, Soon Young; Kim, Man Soo; Oh, Su Ja; Chung, Sung Kun

    2013-09-01

    To evaluate changes in mean keratometry and to compare wound repair with corneal lamellar grafts in rabbit eyes using human synthetic tissue adhesives and 10-0 nylon. Corneal grafts were made using a 6.0-mm-diameter trephine and blades in the eyes of 15 New Zealand white rabbits. Human fibrin tissue adhesive (Tisseel) was used in group 1, human fibrin tissue adhesive (Beriplast P) was used in group 2, polyethylene glycol adhesive (Coseal) was used in group 3, and 8 bite sutures with 10-0 nylon were used in group 4 (control) for lamellar keratoplasty. Four bite sutures were made with 10-0 nylon in groups 1, 2, and 3. Slit-lamp microscopy and keratometry were performed at 3 days and 1, 2, and 4 weeks after the surgery. Histopathologic and electromicroscopic examinations were performed 4 weeks after the surgery. No inflammation or corneal toxicity was seen in groups 1 and 2. Histologically, a few inflammatory cells were seen in groups 3 and 4. Groups 1, 2, and 3 showed no statistically significant changes in mean keratometry at 4 weeks postoperatively compared with preoperative mean keratometry (Wilcoxon signed-rank test, P = 0.178, 0.208, and 0.889, respectively). The control group showed significant changes in mean keratometry at 4 weeks postoperatively (Wilcoxon signed-rank test, P = 0.018). Human fibrin tissue adhesives were well tolerated in rabbit eyes, with no apparent corneal toxicity. Polyethylene glycol adhesive showed more inflammation and insufficient wound repair compared with human fibrin tissue adhesives. Therefore, human fibrin tissue adhesives can be used as an alternative to sutures in lamellar keratoplasty.

  13. Micromechanics of Ultrafine Particle Adhesion—Contact Models

    NASA Astrophysics Data System (ADS)

    Tomas, Jürgen

    2009-06-01

    Ultrafine, dry, cohesive and compressible powders (particle diameter d<10 μm) show a wide variety of flow problems that cause insufficient apparatus and system reliability of processing plants. Thus, the understanding of the micromechanics of particle adhesion is essential to assess the product quality and to improve the process performance in particle technology. Comprehensive models are shown that describe the elastic-plastic force-displacement and frictional moment-angle behavior of adhesive contacts of isotropic smooth spheres. By the model stiff particles with soft contacts, a sphere-sphere interaction of van der Waals forces without any contact deformation describes the stiff attractive term. But, the soft micro-contact response generates a flattened contact, i.e. plate-plate interaction, and increasing adhesion. These increasing adhesion forces between particles directly depend on this frozen irreversible deformation. Thus, the adhesion force is found to be load dependent. It contributes to the tangential forces in an elastic-plastic frictional contact with partially sticking and micro-slip within the contact plane. The load dependent rolling resistance and torque of mobilized frictional contact rotation (spin around its principal axis) are also shown. This reasonable combination of particle contact micromechanics and powder continuum mechanics is used to model analytically the macroscopic friction limits of incipient powder consolidation, yield and cohesive steady-state shear flow on physical basis.

  14. Childhood Soft Tissue Sarcoma Treatment (PDQ®)—Patient Version

    Cancer.gov

    Childhood soft tissue sarcoma treatment options include surgery, radiation therapy, chemotherapy, observation, targeted therapy, immunotherapy and other medications.  Learn more about the diagnosis and treatment of the many types of childhood soft tissue sarcoma in this expert-reviewed summary.

  15. Hard and soft tissue augmentation in a postorthodontic patient: a case report.

    PubMed

    Bonacci, Fred J

    2011-02-01

    A combination of hard and soft tissue grafting is used to augment a thin biotype. A 26-year-old woman with mandibular anterior flaring and Miller Class I and III recessions requested interceptive treatment. Surgery included a full-thickness buccal flap, intramarrow penetrations, bone graft placement, and primary flap closure. Postoperative visits were at 2 and 4 weeks and 2, 3, and 6 months. Stage-two surgery consisted of submerged connective tissue graft placement. Postoperative visits were completed at 2, 4, 6, and 8 weeks and 1 year. Follow-up was completed 3 years after the initial surgery. Interradicular concavities were resolved and gingival biotype was augmented. Soft tissue recession remained at 6 months. Reentry revealed clinical labial plate augmentation; 2 mm was achieved at the lateral incisors and the left central incisor and 3 mm was achieved at the right canine. No bone augmentation was achieved on the left canine and right central incisor. The dehiscence at the right central incisor appeared narrower. Overall, a 2- to 3-mm gain in alveolar bone thickness/height was observed. Two months after stage-two surgery, near complete root coverage was achieved; 1 mm of recession remained on the left central incisor. There was a soft tissue thickness gain of 2 mm without any visual difference in keratinized tissue height. Interradicular concavities were eliminated; the soft tissue was augmented and the gingival biotype was altered. Interdental soft tissue craters remained. One year after connective tissue graft placement, there was near complete root coverage at the left central incisor, which at 2 months experienced residual recession. Interradicular concavities and interdental soft tissue craters were eliminated with soft tissue augmentation, including clinical reestablishment of the mucogingival junction. Clinical stability remained 3 years after the initial surgery, with the patient noting comfort during mastication and routine oral hygiene. A clinical increase in labial plate thickness, in conjunction with soft tissue augmentation, appears to provide for continued stability and decreased potential for future clinical attachment loss.

  16. Polymer structure-property requirements for stereolithographic 3D printing of soft tissue engineering scaffolds.

    PubMed

    Mondschein, Ryan J; Kanitkar, Akanksha; Williams, Christopher B; Verbridge, Scott S; Long, Timothy E

    2017-09-01

    This review highlights the synthesis, properties, and advanced applications of synthetic and natural polymers 3D printed using stereolithography for soft tissue engineering applications. Soft tissue scaffolds are of great interest due to the number of musculoskeletal, cardiovascular, and connective tissue injuries and replacements humans face each year. Accurately replacing or repairing these tissues is challenging due to the variation in size, shape, and strength of different types of soft tissue. With advancing processing techniques such as stereolithography, control of scaffold resolution down to the μm scale is achievable along with the ability to customize each fabricated scaffold to match the targeted replacement tissue. Matching the advanced manufacturing technique to polymer properties as well as maintaining the proper chemical, biological, and mechanical properties for tissue replacement is extremely challenging. This review discusses the design of polymers with tailored structure, architecture, and functionality for stereolithography, while maintaining chemical, biological, and mechanical properties to mimic a broad range of soft tissue types. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. How to use PRICE treatment for soft tissue injuries.

    PubMed

    Norton, Cormac

    2016-08-24

    Rationale and key points This article assists nurses to use the acronym PRICE (protection, rest, ice, compression and elevation) to guide the treatment of patients with uncomplicated soft tissue injuries to their upper or lower limbs. » Treatment of soft tissue injuries to limbs is important to reduce complications following injury, alleviate pain and ensure normal limb function is restored promptly. » Nurses should have an understanding of the rationale and evidence base supporting PRICE treatment of soft tissue injuries. » Providing accurate information to patients and carers about the management of soft tissue injuries and anticipated recovery time is an important aspect of treatment. » Further research is required to develop best practice in the treatment of soft tissue injuries. Reflective activity 'How to' articles can help you update your practice and ensure it remains evidence based. Apply this article to your practice. Reflect on and write a short account of: 1. How this article might change your practice when managing patients with soft tissue injuries to upper or lower limbs. 2. Positive elements of your current practice and those that could be enhanced. Subscribers can upload their reflective accounts at: rcni.com/portfolio.

  18. A Computational Modeling Approach for Investigating Soft Tissue Balancing in Bicruciate Retaining Knee Arthroplasty

    PubMed Central

    Amiri, Shahram; Wilson, David R.

    2012-01-01

    Bicruciate retaining knee arthroplasty, although has shown improved functions and patient satisfaction compared to other designs of total knee replacement, remains a technically demanding option for treating severe cases of arthritic knees. One of the main challenges in bicruciate retaining arthroplasty is proper balancing of the soft tissue during the surgery. In this study biomechanics of soft tissue balancing was investigated using a validated computational model of the knee joint with high fidelity definitions of the soft tissue structures along with a Taguchi method for design of experiments. The model was used to simulate intraoperative balancing of soft tissue structures following the combinations suggested by an orthogonal array design. The results were used to quantify the corresponding effects on the laxity of the joint under anterior-posterior, internal-external, and varus-valgus loads. These effects were ranked for each ligament bundle to identify the components of laxity which were most sensitive to the corresponding surgical modifications. The resulting map of sensitivity for all the ligament bundles determined the components of laxity most suitable for examination during intraoperative balancing of the soft tissue. Ultimately, a sequence for intraoperative soft tissue balancing was suggested for a bicruciate retaining knee arthroplasty. PMID:23082090

  19. Health, Maintenance, and Recovery of Soft Tissues around Implants.

    PubMed

    Wang, Yulan; Zhang, Yufeng; Miron, Richard J

    2016-06-01

    The health of peri-implant soft tissues is one of the most important aspects of osseointegration necessary for the long-term survival of dental implants. To review the process of soft tissue healing around osseointegrated implants and discuss the maintenance requirements as well as the possible short-comings of peri-implant soft tissue integration. Literature search on the process involved in osseointegration, soft tissue healing and currently available treatment modalities was performed and a brief description of each process was provided. The peri-implant interface has been shown to be less effective than natural teeth in resisting bacterial invasion because gingival fiber alignment and reduced vascular supply make it more vulnerable to subsequent peri-implant disease and future bone loss around implants. And we summarized common procedures which have been shown to be effective in preventing peri-implantitis disease progression as well as clinical techniques utilized to regenerate soft tissues with bone loss in advanced cases of peri-implantitis. Due to the difference between peri-implant interface and natural teeth, clinicians and patients should pay more attention in the maintenance and recovery of soft tissues around implants. © 2015 Wiley Periodicals, Inc.

  20. Dual-Mode Adhesive Pad

    NASA Technical Reports Server (NTRS)

    Hartz, Leslie

    1994-01-01

    Tool helps worker grip and move along large, smooth structure with no handgrips or footholds. Adheres to surface but easily released by actuating simple mechanism. Includes handle and segmented contact-adhesive pad. Bulk of pad made of soft plastic foam conforming to surface of structure. Each segment reinforced with rib. In sticking mode, ribs braced by side catches. In peeling mode, side catches retracted, and segmented adhesive pad loses its stiffness. Modified versions useful in inspecting hulls of ships and scaling walls in rescue operations.

  1. The Effect of Two Soft Drinks on Bracket Bond Strength and on Intact and Sealed Enamel: An In Vitro Study

    PubMed Central

    Pasha, Azam; Sindhu, D; Nayak, Rabindra S; Mamatha, J; Chaitra, K R; Vishwakarma, Swati

    2015-01-01

    Background and Objectives: This study was conducted to evaluate the effect of two soft drinks, Coca-Cola and Mirinda orange on bracket bond strength, on adhesive remnant on teeth after debonding the bracket, and to observe by means of scanning electron microscope (SEM) the effect of these drinks on intact and sealed enamel. Methods: 120 non-carious maxillary premolar teeth already extracted for Orthodontic purposes were taken and divided into three groups, i.e., Coca-Cola drink, Mirinda orange, and control (artificial saliva) group. Brackets were bonded using conventional methods. Teeth were kept in soft drinks for 15 days, for 15 min, 3 times a day, separated by intervals of 2 h. At other times, they were kept in artificial saliva. The samples, thus obtained were evaluated for shear bond strength using the universal testing machine and subsequently subjected for adhesive remnant index (ARI) scores. SEM study on all the three groups was done for evaluating enamel surface of the intact and sealed enamel. Results: The lowest mean resistance to shearing forces was shown by Mirinda orange group (5.30 ± 2.74 Mpa) followed by Coca-Cola group (6.24 ± 1.59 Mpa) and highest resistance to shearing forces by control group (7.33 ± 1.72 Mpa). The ARI scores revealed a cohesive failure in control samples and an adhesive failure in Mirinda and cola samples. SEM results showed areas of defect due to erosion caused by acidic soft drinks on intact and sealed enamel surface. Conclusion: Mirinda group showed the lowest resistance to shearing forces, followed by Coca-Cola group and with the highest resistance to shearing forces by the control group. There were significant differences between the control group and the study groups. Areas of defects, which were caused by erosion related to acidic soft drinks on the enamel surface around the adhesive, were seen. Areas of defects caused by Coca-Cola were more extensive when compared to Mirinda orange drink. PMID:26668477

  2. A Review of Cell Adhesion Studies for Biomedical and Biological Applications.

    PubMed

    Khalili, Amelia Ahmad; Ahmad, Mohd Ridzuan

    2015-08-05

    Cell adhesion is essential in cell communication and regulation, and is of fundamental importance in the development and maintenance of tissues. The mechanical interactions between a cell and its extracellular matrix (ECM) can influence and control cell behavior and function. The essential function of cell adhesion has created tremendous interests in developing methods for measuring and studying cell adhesion properties. The study of cell adhesion could be categorized into cell adhesion attachment and detachment events. The study of cell adhesion has been widely explored via both events for many important purposes in cellular biology, biomedical, and engineering fields. Cell adhesion attachment and detachment events could be further grouped into the cell population and single cell approach. Various techniques to measure cell adhesion have been applied to many fields of study in order to gain understanding of cell signaling pathways, biomaterial studies for implantable sensors, artificial bone and tooth replacement, the development of tissue-on-a-chip and organ-on-a-chip in tissue engineering, the effects of biochemical treatments and environmental stimuli to the cell adhesion, the potential of drug treatments, cancer metastasis study, and the determination of the adhesion properties of normal and cancerous cells. This review discussed the overview of the available methods to study cell adhesion through attachment and detachment events.

  3. A Review of Cell Adhesion Studies for Biomedical and Biological Applications

    PubMed Central

    Ahmad Khalili, Amelia; Ahmad, Mohd Ridzuan

    2015-01-01

    Cell adhesion is essential in cell communication and regulation, and is of fundamental importance in the development and maintenance of tissues. The mechanical interactions between a cell and its extracellular matrix (ECM) can influence and control cell behavior and function. The essential function of cell adhesion has created tremendous interests in developing methods for measuring and studying cell adhesion properties. The study of cell adhesion could be categorized into cell adhesion attachment and detachment events. The study of cell adhesion has been widely explored via both events for many important purposes in cellular biology, biomedical, and engineering fields. Cell adhesion attachment and detachment events could be further grouped into the cell population and single cell approach. Various techniques to measure cell adhesion have been applied to many fields of study in order to gain understanding of cell signaling pathways, biomaterial studies for implantable sensors, artificial bone and tooth replacement, the development of tissue-on-a-chip and organ-on-a-chip in tissue engineering, the effects of biochemical treatments and environmental stimuli to the cell adhesion, the potential of drug treatments, cancer metastasis study, and the determination of the adhesion properties of normal and cancerous cells. This review discussed the overview of the available methods to study cell adhesion through attachment and detachment events. PMID:26251901

  4. A novel laparoscopic grasper with two parallel jaws capable of extracting the mechanical behaviour of soft tissues.

    PubMed

    Nazarynasab, Dariush; Farahmand, Farzam; Mirbagheri, Alireza; Afshari, Elnaz

    2017-07-01

    Data related to force-deformation behaviour of soft tissue plays an important role in medical/surgical applications such as realistically modelling mechanical behaviour of soft tissue as well as minimally invasive surgery (MIS) and medical diagnosis. While the mechanical behaviour of soft tissue is very complex due to its different constitutive components, some issues increase its complexity like behavioural changes between the live and dead tissues. Indeed, an adequate quantitative description of mechanical behaviour of soft tissues requires high quality in vivo experimental data to be obtained and analysed. This paper describes a novel laparoscopic grasper with two parallel jaws capable of obtaining compressive force-deformation data related to mechanical behaviour of soft tissues. This new laparoscopic grasper includes four sections as mechanical hardware, sensory part, electrical/electronical part and data storage part. By considering a unique design for mechanical hardware, data recording conditions will be close to unconfined-compression-test conditions; so obtained data can be properly used in extracting the mechanical behaviour of soft tissues. Also, the other distinguishing feature of this new system is its applicability during different laparoscopic surgeries and subsequently obtaining in vivo data. However, more preclinical examinations are needed to evaluate the practicality of the novel laparoscopic grasper with two parallel jaws.

  5. Facial soft tissue thickness in skeletal type I Japanese children.

    PubMed

    Utsuno, Hajime; Kageyama, Toru; Deguchi, Toshio; Umemura, Yasunobu; Yoshino, Mineo; Nakamura, Hiroshi; Miyazawa, Hiroo; Inoue, Katsuhiro

    2007-10-25

    Facial reconstruction techniques used in forensic anthropology require knowledge of the facial soft tissue thickness of each race if facial features are to be reconstructed correctly. If this is inaccurate, so also will be the reconstructed face. Knowledge of differences by age and sex are also required. Therefore, when unknown human skeletal remains are found, the forensic anthropologist investigates for race, sex, and age, and for other variables of relevance. Cephalometric X-ray images of living persons can help to provide this information. They give an approximately 10% enlargement from true size and can demonstrate the relationship between soft and hard tissue. In the present study, facial soft tissue thickness in Japanese children was measured at 12 anthropological points using X-ray cephalometry in order to establish a database for facial soft tissue thickness. This study of both boys and girls, aged from 6 to 18 years, follows a previous study of Japanese female children only, and focuses on facial soft tissue thickness in only one skeletal type. Sex differences in thickness of tissue were found from 12 years of age upwards. The study provides more detailed and accurate measurements than past reports of facial soft tissue thickness, and reveals the uniqueness of the Japanese child's facial profile.

  6. Non Lipomatous Benign Lesions Mimicking Soft-tissue Sarcomas: A Pictorial Essay

    PubMed Central

    CORAN, ALESSANDRO; ORSATTI, GIOVANNA; CRIMÌ, FILIPPO; RASTRELLI, MARCO; DI MAGGIO, ANTONIO; PONZONI, ALBERTO; ATTAR, SHADY; STRAMARE, ROBERTO

    2018-01-01

    The incidental finding of soft tissue masses is a challenge for the radiologist. Benign and malignant lesions can be differentiated relying on patient history, symptoms and mostly with the help of imaging. Ultrasound (US), computed tomography (CT) and magnetic resonance imaging (MRI) become fundamental in order to distinguish these lesions but the radiologist needs to know the main characteristics of benign soft tissue masses and sarcomas. Herein, we present a pictorial review of lesions mimicking soft tissue sarcomas features. PMID:29475903

  7. Fabrication of polyurethane and polyurethane based composite fibres by the electrospinning technique for soft tissue engineering of cardiovascular system.

    PubMed

    Kucinska-Lipka, J; Gubanska, I; Janik, H; Sienkiewicz, M

    2015-01-01

    Electrospinning is a unique technique, which provides forming of polymeric scaffolds for soft tissue engineering, which include tissue scaffolds for soft tissues of the cardiovascular system. Such artificial soft tissues of the cardiovascular system may possess mechanical properties comparable to native vascular tissues. Electrospinning technique gives the opportunity to form fibres with nm- to μm-scale in diameter. The arrangement of obtained fibres and their surface determine the biocompatibility of the scaffolds. Polyurethanes (PUs) are being commonly used as a prosthesis of cardiovascular soft tissues due to their excellent biocompatibility, non-toxicity, elasticity and mechanical properties. PUs also possess fine spinning properties. The combination of a variety of PU properties with an electrospinning technique, conducted at the well tailored conditions, gives unlimited possibilities of forming novel polyurethane materials suitable for soft tissue scaffolds applied in cardiovascular tissue engineering. This paper can help researches to gain more widespread and deeper understanding of designing electrospinable PU materials, which may be used as cardiovascular soft tissue scaffolds. In this paper we focus on reagents used in PU synthesis designed to increase PU biocompatibility (polyols) and biodegradability (isocyanates). We also describe suggested surface modifications of electrospun PUs, and the direct influence of surface wettability on providing enhanced biocompatibility of scaffolds. We indicate a great influence of electrospinning parameters (voltage, flow rate, working distance) and used solvents (mostly DMF, THF and HFIP) on fibre alignment and diameter - what impacts the biocompatibility and hemocompatibility of such electrospun PU scaffolds. Moreover, we present PU modifications with natural polymers with novel approach applied in electrospinning of PU scaffolds. This work may contribute with further developing of novel electrospun PUs, which may be applied as soft tissue scaffolds of the cardiovascular system. Copyright © 2014. Published by Elsevier B.V.

  8. Wound Healing Complications Following Guided Bone Regeneration for Ridge Augmentation: A Systematic Review and Meta-Analysis.

    PubMed

    Lim, Glendale; Lin, Guo-Hao; Monje, Alberto; Chan, Hsun-Liang; Wang, Hom-Lay

    The rate of developing soft tissue complications that accompany guided bone regeneration (GBR) procedures varies widely, from 0% to 45%. The present review was conducted to investigate the rate for resorbable versus nonresorbable membranes and the timing of soft tissue complications. Electronic and manual literature searches were conducted by two independent reviewers using several databases, including MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, and Cochrane Oral Health Group Trials Register, for articles published through July 2015, with no language restriction. Articles were included if they were clinical trials aimed at demonstrating the incidence of soft tissue complications following GBR procedures. Overall, 21 and 15 articles were included in the qualitative and quantitative synthesis, respectively. The weighted complication rate of the overall soft tissue complications, including membrane exposure, soft tissue dehiscence, and acute infection/abscess, into the calculation was 16.8% (95% CI = 10.6% to 25.4%). When considering the complication rate based on membrane type used, resorbable membrane was associated with a weighted complication rate of 18.3% (95% CI: 10.4% to 30.4%) and nonresorbable membrane with a rate of 17.6% (95% CI: 10.0% to 29.3%). Moreover, soft tissue lesions were reported as early as 1 week and as late as 6 months based on the included studies. Soft tissue complications after GBR are common (16.8%). Membrane type did not appear to significantly affect the complication rate, based on the limited number of data retrieved in this study. Technique sensitivity (ie, soft tissue management) may still be regarded as the main component to avoid soft tissue complications and, hence, to influence the success of bone regenerative therapy.

  9. Soft-Tissue Sarcomas of the Abdomen and Pelvis: Radiologic-Pathologic Features, Part 1-Common Sarcomas: From the Radiologic Pathology Archives.

    PubMed

    Levy, Angela D; Manning, Maria A; Al-Refaie, Waddah B; Miettinen, Markku M

    2017-01-01

    Soft-tissue sarcomas are a diverse group of rare mesenchymal malignancies that can arise at any location in the body and affect all age groups. These sarcomas are most common in the extremities, trunk wall, retroperitoneum, and head and neck. In the adult population, soft-tissue sarcomas arising in the abdomen and pelvis are often large masses at the time of diagnosis because they are usually clinically silent or cause vague or mild symptoms until they invade or compress vital organs. In contrast, soft-tissue sarcomas arising from the abdominal wall come to clinical attention earlier in the course of disease because they cause a palpable mass, abdominal wall deformity, or pain that is more clinically apparent. The imaging features of abdominal and pelvic sarcomas and abdominal wall sarcomas can be nonspecific and overlap with more common pathologic conditions, making diagnosis difficult or, in some cases, delaying diagnosis. Liposarcoma (well-differentiated and dedifferentiated liposarcomas), leiomyosarcoma, and gastrointestinal stromal tumor (GIST) are the most common intra-abdominal primary sarcomas. Any soft-tissue sarcoma can arise in the abdominal wall. Knowledge of the classification and pathologic features of soft-tissue sarcomas, the anatomic locations where they occur, and their cross-sectional imaging features helps the radiologist establish the diagnosis or differential diagnosis so that patients with soft-tissue sarcomas can receive optimal treatment and management. In part 1 of this article, the most common soft-tissue sarcomas (liposarcoma, leiomyosarcoma, and GIST) are reviewed, with a discussion on anatomic locations, classification, clinical considerations, and differential diagnosis. Part 2 will focus on the remainder of the soft-tissue sarcomas occurring in the abdomen and pelvis.

  10. Arthroscopic evaluation of soft tissue injuries in tibial plateau fractures: retrospective analysis of 98 cases.

    PubMed

    Abdel-Hamid, Mohamed Zaki; Chang, Chung-Hsun; Chan, Yi-Sheng; Lo, Yang-Pin; Huang, Jau-Wen; Hsu, Kuo-Yao; Wang, Ching-Jen

    2006-06-01

    This investigation arthroscopically assesses the frequency of soft tissue injury in tibial plateau fracture according to the severity of fracture patterns. We hypothesized that use of arthroscopy to evaluate soft tissue injury in tibial plateau fractures would reveal a greater number of associated injuries than have previously been reported. From March 1996 to December 2003, 98 patients with closed tibial plateau fractures were treated with arthroscopically assisted reduction and osteosynthesis, with precise diagnosis and management of associated soft tissue injuries. Arthroscopic findings for associated soft tissue injuries were recorded, and the relationship between fracture type and soft tissue injury was then analyzed. The frequency of associated soft tissue injury in this series was 71% (70 of 98). The menisci were injured in 57% of subjects (56 in 98), the anterior cruciate ligament (ACL) in 25% (24 of 98), the posterior cruciate ligament (PCL) in 5% (5 of 98), the lateral collateral ligament (LCL) in 3% (3 of 98), the medial collateral ligament (MCL) in 3% (3 of 98), and the peroneal nerve in 1% (1 of 98); none of the 98 patients exhibited injury to the arteries. No significant association was noted between fracture type and incidence of meniscus, PCL, LCL, MCL, artery, and nerve injury. However, significantly higher injury rates for the ACL were observed in type IV and VI fractures. Soft tissue injury was associated with all types of tibial plateau fracture. Menisci (peripheral tear) and ACL (bony avulsion) were the most commonly injured sites. A variety of soft tissue injuries are common with tibial plateau fracture; these can be diagnosed with the use of an arthroscope. Level III, diagnostic study.

  11. Soft-Tissue Sarcomas of the Abdomen and Pelvis: Radiologic-Pathologic Features, Part 1—Common Sarcomas: From the Radiologic Pathology Archives

    PubMed Central

    Manning, Maria A.; Al-Refaie, Waddah B.; Miettinen, Markku M.

    2017-01-01

    Soft-tissue sarcomas are a diverse group of rare mesenchymal malignancies that can arise at any location in the body and affect all age groups. These sarcomas are most common in the extremities, trunk wall, retroperitoneum, and head and neck. In the adult population, soft-tissue sarcomas arising in the abdomen and pelvis are often large masses at the time of diagnosis because they are usually clinically silent or cause vague or mild symptoms until they invade or compress vital organs. In contrast, soft-tissue sarcomas arising from the abdominal wall come to clinical attention earlier in the course of disease because they cause a palpable mass, abdominal wall deformity, or pain that is more clinically apparent. The imaging features of abdominal and pelvic sarcomas and abdominal wall sarcomas can be nonspecific and overlap with more common pathologic conditions, making diagnosis difficult or, in some cases, delaying diagnosis. Liposarcoma (well-differentiated and dedifferentiated liposarcomas), leiomyosarcoma, and gastrointestinal stromal tumor (GIST) are the most common intra-abdominal primary sarcomas. Any soft-tissue sarcoma can arise in the abdominal wall. Knowledge of the classification and pathologic features of soft-tissue sarcomas, the anatomic locations where they occur, and their cross-sectional imaging features helps the radiologist establish the diagnosis or differential diagnosis so that patients with soft-tissue sarcomas can receive optimal treatment and management. In part 1 of this article, the most common soft-tissue sarcomas (liposarcoma, leiomyosarcoma, and GIST) are reviewed, with a discussion on anatomic locations, classification, clinical considerations, and differential diagnosis. Part 2 will focus on the remainder of the soft-tissue sarcomas occurring in the abdomen and pelvis. PMID:28287938

  12. Quantitative Imaging of Young's Modulus of Soft Tissues from Ultrasound Water Jet Indentation: A Finite Element Study

    PubMed Central

    Lu, Min-Hua; Mao, Rui; Lu, Yin; Liu, Zheng; Wang, Tian-Fu; Chen, Si-Ping

    2012-01-01

    Indentation testing is a widely used approach to evaluate mechanical characteristics of soft tissues quantitatively. Young's modulus of soft tissue can be calculated from the force-deformation data with known tissue thickness and Poisson's ratio using Hayes' equation. Our group previously developed a noncontact indentation system using a water jet as a soft indenter as well as the coupling medium for the propagation of high-frequency ultrasound. The novel system has shown its ability to detect the early degeneration of articular cartilage. However, there is still lack of a quantitative method to extract the intrinsic mechanical properties of soft tissue from water jet indentation. The purpose of this study is to investigate the relationship between the loading-unloading curves and the mechanical properties of soft tissues to provide an imaging technique of tissue mechanical properties. A 3D finite element model of water jet indentation was developed with consideration of finite deformation effect. An improved Hayes' equation has been derived by introducing a new scaling factor which is dependent on Poisson's ratios v, aspect ratio a/h (the radius of the indenter/the thickness of the test tissue), and deformation ratio d/h. With this model, the Young's modulus of soft tissue can be quantitatively evaluated and imaged with the error no more than 2%. PMID:22927890

  13. New Technique of Applying Topical Oxygen Therapy as a Cost-Effective Procedure.

    PubMed

    Agarwal, Vivek; Aroor, Shashank; Gupta, Nikhil; Gupta, Arun; Agarwal, Nitin; Kaur, Navneet

    2015-12-01

    To describe the newly designed technique of applying topical oxygen therapy for large wounds. C arm sterile disposable cover is used for covering the wound. For abdominal and pelvis wounds, two artificial holes are created at one end of the cover for the inclusion of the limb. Free end of the cover is secured with adhesive, and a hole is created for the insertion of the suction catheter. Oxygen cylinder is connected to the suction catheter, and oxygen is supplied at the rate of 10 L/min. Three patients were treated with topical oxygen therapy. These patients were cases of necrotizing soft tissue infections and large post traumatic wounds. There were less requirements of debridement and granulation tissue appeared earlier. The cost of one cycle of the therapy is less than 500 INR. Topical oxygen therapy is the recent modality for improved wound healing. The novel method of applying topical oxygen devised by us is effective, feasible, and cost-effective as compared to standard devices.

  14. Altering the concentration of silica tunes the functional properties of collagen-silica composite scaffolds to suit various clinical requirements.

    PubMed

    Perumal, Sathiamurthi; Ramadass, Satiesh Kumar; Gopinath, Arun; Madhan, Balaraman; Shanmugam, Ganesh; Rajadas, Jayakumar; Mandal, Asit Baran

    2015-12-01

    The success of a tissue engineering scaffold depends on a fine balance being achieved between the physicochemical and biological properties. This study attempts to understand the influence of silica concentration on the functional properties of collagen-silica (CS) composite scaffolds for soft tissue engineering applications. Increasing the ratio of silica to collagen (0.25, 0.5, 0.75, 1.0, 1.25, 1.5 and 2.0 w/w) gave a marked advantage in terms of improving the water uptake and compressive modulus of the CS scaffolds, while also enhancing the biological stability and the turnover time. With increase in silica concentration the water uptake and compressive modulus increased concurrently, whereas it was not so for surface porous architecture and biocompatibility which are crucial for cell adhesion and infiltration. Silica:collagen ratio of ≤1 exhibits favourable surface biocompatibility, and any further increase in silica concentration has a detrimental effect. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. [Design and application of silver needle-knife].

    PubMed

    Sun, Guodong; Shi, Bin; Zhang, Benwu; Xu, Haidong

    2015-04-01

    A silver needle-knife which has the dual function of silver needle and needle-knife is designed. The main components of this silver needle-knife are approximately 50% silver and approximately 50% nichrome. The silver needle-knife is composed of five parts, including needle-knife tail, spiral handle; steering handle, needle-knife body and needle-knife edge. It converges the advantages of needle-knife and silver needle, which can cut loose of diseased tissue and peel adhesion of lesions, but also be heated with moxa cone and thermal therapeutic instrument, and connect with electroacupuncture apparatus. It has the function of warming channel and removing coldness, dispelling wind and eliminating dampness, resolving spasm and relieving pain, dredging the channel and so on. Due to the spiral handle and the steering handle, the operation is easier, which reduces the blindness of cutting and increase the safety. It is mainly used for soft tissue injury, rheumatism and rheumatoid arthritis, as well as degenerative diseases of spine and joint, and it has obvious efficacy on some internal medical diseases.

  16. Vertical Ridge Augmentation and Soft Tissue Reconstruction of the Anterior Atrophic Maxillae: A Case Series.

    PubMed

    Urban, Istvan A; Monje, Alberto; Wang, Hom-Lay

    2015-01-01

    Severe vertical ridge deficiency in the anterior maxilla represents one of the most challenging clinical scenarios in the bone regeneration arena. As such, a combination of vertical bone augmentation using various biomaterials and soft tissue manipulation is needed to obtain successful outcomes. The present case series describes a novel approach to overcome vertical deficiencies in the anterior atrophied maxillae by using a mixture of autologous and anorganic bovine bone. Soft tissue manipulation including, but not limited to, free soft tissue graft was used to overcome the drawbacks of vertical bone augmentation (eg, loss of vestibular depth and keratinized mucosa). By combining soft and hard tissue grafts, optimum esthetic and long-term implant prosthesis stability can be achieved and sustained.

  17. Proteomic Analysis of Gingival Tissue and Alveolar Bone during Alveolar Bone Healing*

    PubMed Central

    Yang, Hee-Young; Kwon, Joseph; Kook, Min-Suk; Kang, Seong Soo; Kim, Se Eun; Sohn, Sungoh; Jung, Seunggon; Kwon, Sang-Oh; Kim, Hyung-Seok; Lee, Jae Hyuk; Lee, Tae-Hoon

    2013-01-01

    Bone tissue regeneration is orchestrated by the surrounding supporting tissues and involves the build-up of osteogenic cells, which orchestrate remodeling/healing through the expression of numerous mediators and signaling molecules. Periodontal regeneration models have proven useful for studying the interaction and communication between alveolar bone and supporting soft tissue. We applied a quantitative proteomic approach to analyze and compare proteins with altered expression in gingival soft tissue and alveolar bone following tooth extraction. For target identification and validation, hard and soft tissue were extracted from mini-pigs at the indicated times after tooth extraction. From triplicate experiments, 56 proteins in soft tissue and 27 proteins in alveolar bone were found to be differentially expressed before and after tooth extraction. The expression of 21 of those proteins was altered in both soft tissue and bone. Comparison of the activated networks in soft tissue and alveolar bone highlighted their distinct responsibilities in bone and tissue healing. Moreover, we found that there is crosstalk between identified proteins in soft tissue and alveolar bone with respect to cellular assembly, organization, and communication. Among these proteins, we examined in detail the expression patterns and associated networks of ATP5B and fibronectin 1. ATP5B is involved in nucleic acid metabolism, small molecule biochemistry, and neurological disease, and fibronectin 1 is involved in cellular assembly, organization, and maintenance. Collectively, our findings indicate that bone regeneration is accompanied by a profound interaction among networks regulating cellular resources, and they provide novel insight into the molecular mechanisms involved in the healing of periodontal tissue after tooth extraction. PMID:23824910

  18. Microbial adhesion to silicone hydrogel lenses: a review.

    PubMed

    Willcox, Mark D P

    2013-01-01

    Microbial adhesion to contact lenses is believed to be one of the initiating events in the formation of many corneal infiltrative events, including microbial keratitis, that occur during contact lens wear. The advent of silicone hydrogel lenses has not reduced the incidence of these events. This may partly be related to the ability of microbes to adhere to these lenses. The aim of this study was to review the published literature on microbial adhesion to contact lenses, focusing on adhesion to silicone hydrogel lenses. The literature on microbial adhesion to contact lenses was searched, along with associated literature on adverse events that occur during contact lens wear. Particular reference was paid to the years 1995 through 2012 because this encompasses the time when the first clinical trials of silicone hydrogel lenses were reported, and their commercial availability and the publication of epidemiology studies on adverse events were studied. In vitro studies of bacterial adhesion to unworn silicone hydrogel lens have shown that generally, bacteria adhere to these lenses in greater numbers than to the hydroxyethyl methacrylate-based soft lenses. Lens wear has different effects on microbial adhesion, and this is dependent on the type of lens and microbial species/genera that is studied. Biofilms that can be formed on any lens type tend to protect the bacteria and fungi from the effects on disinfectants. Fungal hyphae can penetrate the surface of most types of lenses. Acanthamoeba adhere in greater numbers to first-generation silicone hydrogel lenses compared with the second-generation or hydroxyethyl methacrylate-based soft lenses. Microbial adhesion to silicone hydrogel lenses occurs and is associated with the production of corneal infiltrative events during lens wear.

  19. Soft tissue augmentation around osseointegrated and uncovered dental implants: a systematic review.

    PubMed

    Bassetti, Renzo G; Stähli, Alexandra; Bassetti, Mario A; Sculean, Anton

    2017-01-01

    The aim was to compile the current knowledge about the efficacy of different soft tissue correction methods around osseointegrated, already uncovered and/or loaded (OU/L) implants with insufficient soft tissue conditions. Procedures to increase peri-implant keratinized mucosa (KM) width and/or soft tissue volume were considered. Screening of two databases: MEDLINE (PubMed) and EMBASE (OVID), and manual search of articles were performed. Human studies reporting on soft tissue augmentation/correction methods around OU/L implants up to June 30, 2016, were considered. Quality assessment of selected full-text articles to weight risk of bias was performed using the Cochrane collaboration's tool. Overall, four randomized controlled trials (risk of bias = high/low) and five prospective studies (risk of bias = high) were included. Depending on the surgical techniques and graft materials, the enlargement of keratinized tissue (KT) ranged between 1.15 ± 0.81 and 2.57 ± 0.50 mm. The apically positioned partial thickness flap (APPTF), in combination with a free gingival graft (FGG), a subepithelial connective tissue graft (SCTG), or a xenogeneic graft material (XCM) were most effective. A coronally advanced flap (CAF) combined with SCTG in three, combined with allogenic graft materials (AMDA) in one, and a split thickness flap (STF) combined with SCTG in another study showed mean soft tissue recession coverage rates from 28 to 96.3 %. STF combined with XCM failed to improve peri-implant soft tissue coverage. The three APPTF-techniques combined with FGG, SCTG, or XCM achieved comparable enlargements of peri-implant KT. Further, both STF and CAF, both in combination with SCTG, are equivalent regarding recession coverage rates. STF + XCM and CAF + AMDA did not reach significant coverage. In case of soft tissue deficiency around OU/L dental implants, the selection of both an appropriate surgical technique and a suitable soft tissue graft material is of utmost clinical relevance.

  20. ChainMail based neural dynamics modeling of soft tissue deformation for surgical simulation.

    PubMed

    Zhang, Jinao; Zhong, Yongmin; Smith, Julian; Gu, Chengfan

    2017-07-20

    Realistic and real-time modeling and simulation of soft tissue deformation is a fundamental research issue in the field of surgical simulation. In this paper, a novel cellular neural network approach is presented for modeling and simulation of soft tissue deformation by combining neural dynamics of cellular neural network with ChainMail mechanism. The proposed method formulates the problem of elastic deformation into cellular neural network activities to avoid the complex computation of elasticity. The local position adjustments of ChainMail are incorporated into the cellular neural network as the local connectivity of cells, through which the dynamic behaviors of soft tissue deformation are transformed into the neural dynamics of cellular neural network. Experiments demonstrate that the proposed neural network approach is capable of modeling the soft tissues' nonlinear deformation and typical mechanical behaviors. The proposed method not only improves ChainMail's linear deformation with the nonlinear characteristics of neural dynamics but also enables the cellular neural network to follow the principle of continuum mechanics to simulate soft tissue deformation.

  1. The Adjunctive Soft-Tissue Diode Laser in Orthodontics.

    PubMed

    Borzabadi-Farahani, Ali

    2017-04-01

    Lasers are a relatively new addition to the orthodontist's armamentarium. This article reviews the fundamental basic science of available soft-tissue lasers, with an emphasis on diode lasers, and discusses various adjunct applications of the diode laser for soft-tissue orthodontic procedures. Diode lasers function by cutting with an initiated hot tip and produce minimal to no interaction with healthy dental hard tissue, making them suitable for soft-tissue procedures. The contact cutting mode provides enhanced bloodless site visibility and facility to perform delicate soft tissue procedures, which is important in areas with difficult access. Such adjunctive uses include laser gingivectomy to improve oral hygiene or bracket positioning, esthetic laser gingival recontouring, and laser exposure of superficially impacted teeth. Selected cases treated with a 940-nm indium-gallium-arsenide-phosphide (InGaAsP) diode laser will be presented.

  2. Multilevel robustness

    NASA Astrophysics Data System (ADS)

    Girard, Henri-Louis; Khan, Sami; Varanasi, Kripa K.

    2018-03-01

    A combination of hard, soft and nanoscale organic components results in robust superhydrophobic surfaces that can withstand mechanical abrasion and chemical oxidation, and exhibit excellent substrate adhesion.

  3. Enhanced PEDOT adhesion on solid substrates with electrografted P(EDOT-NH2)

    PubMed Central

    Ouyang, Liangqi; Wei, Bin; Kuo, Chin-chen; Pathak, Sheevangi; Farrell, Brendan; Martin, David C.

    2017-01-01

    Conjugated polymers, such as poly(3,4-ethylene dioxythiophene) (PEDOT), have emerged as promising materials for interfacing biomedical devices with tissue because of their relatively soft mechanical properties, versatile organic chemistry, and inherent ability to conduct both ions and electrons. However, their limited adhesion to substrates is a concern for in vivo applications. We report an electrografting method to create covalently bonded PEDOT on solid substrates. An amine-functionalized EDOT derivative (2,3-dihydrothieno[3,4-b][1,4]dioxin-2-yl)methanamine (EDOT-NH2), was synthesized and then electrografted onto conducting substrates including platinum, iridium, and indium tin oxide. The electrografting process was performed under slightly basic conditions with an overpotential of ~2 to 3 V. A nonconjugated, cross-linked, and well-adherent P(EDOT-NH2)–based polymer coating was obtained. We found that the P(EDOT-NH2) polymer coating did not block the charge transport through the interface. Subsequent PEDOT electrochemical deposition onto P(EDOT-NH2)–modified electrodes showed comparable electroactivity to pristine PEDOT coating. With P(EDOT-NH2) as an anchoring layer, PEDOT coating showed greatly enhanced adhesion. The modified coating could withstand extensive ultrasonication (1 hour) without significant cracking or delamination, whereas PEDOT typically delaminated after seconds of sonication. Therefore, this is an effective means to selectively modify microelectrodes with highly adherent and highly conductive polymer coatings as direct neural interfaces. PMID:28275726

  4. Characterization of the gene encoding pinin/DRS/memA and evidence for its potential tumor suppressor function.

    PubMed

    Shi, Y; Ouyang, P; Sugrue, S P

    2000-01-13

    Several cell adhesion-related proteins have been shown to act as tumor-suppressors (TS) in the neoplastic progression of epithelial-derived tumors. Pinin/DRS/memA was first identified in our laboratory and it was shown to be a cell adhesion-related molecule. Our previous study demonstrated that restoration of pinin expression in transformed cells not only positively influenced cellular adhesive properties but also reversed the transformed phenotype to more epithelial-like. Here, we show by FISH analysis that the gene locus for pinin is within 14q13. The alignment of the pinin gene with STS markers localized the gene to the previously identified TS locus D14S75-D14S288. Northern analyses revealed diminished pinin mRNA in renal cell carcinomas (RCC) and certain cancer cell lines. Immunohistochemical examination of tumor samples demonstrated absent or greatly reduced pinin in transitional cell carcinoma (TCC) and RCC tumors. TCC-derived J82 cells as well as EcR-293 cells transfected with full-length pinin cDNA demonstrated inhibition of anchorage-independent growth of cells in soft agar. Furthermore, methylation analyses revealed that aberrant methylation of pinin CpG islands was correlated with decreased/absent pinin expression in a subset of tumor tissues. These data lend significant support to the hypothesis that pinin/DRS/memA may act as a tumor suppressor in certain types of cancers.

  5. Nano-biomimetics for nano/micro tissue regeneration.

    PubMed

    Singh, Dolly; Singh, Deepti; Zo, Sunmi; Han, Sung Soo

    2014-10-01

    Nanostructured biomimetics have recently shown great promise in the field of tissue engineering. They can be used as nanoscaffolds and tailored at the molecular level. The scaffold topography closely resembles the native extracellular matrix in terms of framing, porosity and bio-functionality. This review covers the approaches used for biomimetic fabrication, including soft lithography, the plasmonic nanohybrid matrix method and multilayer self-assembly scaffolds for tissue regeneration. It brings together knowledge from different arenas about the synthesis, characterization and functionalization of matrices to accelerate the tissue regeneration process. Every tissue in the body presents different challenges and requires a specific fabrication process designed to identify and mirror the particular organ. For example, microfluidics systems aim to mimic the extracellular matrix of vascular and cartilage tissue, and these systems have different parts with completely different mechanical strength, cellular adhesion and interplay between matrix and cells. A fully functional nanomatrix designed by a self-assembling methodology for use as a vascular tissue engineering scaffold needs to have intrinsic microvessels that facilitate the transportation of metabolites and nutrients. Similarly, in the case of peripheral nerve regeneration, a scaffold needs to have sufficient mechanical strength to protect the regenerating tissue, yet be biodegradable enough to avoid a possible second surgery. To enhance the functionality of scaffolds, increasing focus has been placed on in vitro and in vivo research to achieve optimal scaffold design. Nanobiomimetics unarguably offer the most suitable physicochemical scaffold properties for tissue regeneration.

  6. The role of radiology in paediatric soft tissue sarcomas

    PubMed Central

    van Rijn, R.; McHugh, K.

    2008-01-01

    Abstract Paediatric soft tissue sarcomas (STS) are a group of malignant tumours that originate from primitive mesenchymal tissue and account for 7% of all childhood tumours. Rhabdomyosarcomas (RMS) and undifferentiated sarcomas account for approximately 50% of soft tissue sarcomas in children and non-rhabdomyomatous soft tissue sarcomas (NRSTS) the remainder. The prognosis and biology of STS tumours vary greatly depending on the age of the patient, the primary site, tumour size, tumour invasiveness, histologic grade, depth of invasion, and extent of disease at diagnosis. Over recent years, there has been a marked improvement in survival rates in children and adolescents with soft tissue sarcoma and ongoing international studies continue to aim to improve these survival rates whilst attempting to reduce the morbidity associated with treatment. Radiology plays a crucial role in the initial diagnosis and staging of STS, in the long term follow-up and in the assessment of many treatment related complications. We review the epidemiology, histology, clinical presentation, staging and prognosis of soft tissue sarcomas and discuss the role of radiology in their management. PMID:18442956

  7. Current dental adhesives systems. A narrative review.

    PubMed

    Milia, Egle; Cumbo, Enzo; Cardoso, Rielson Jose A; Gallina, Giuseppe

    2012-01-01

    Adhesive dentistry is based on the development of materials which establish an effective bond with the tooth tissues. In this context, adhesive systems have attracted considerable research interest in recent years. Successful adhesive bonding depends on the chemistry of the adhesive, on appropriate clinical handling of the material as well as on the knowledge of the morphological changes caused on dental tissue by different bonding procedures. This paper outlines the status of contemporary adhesive systems, with particular emphasis on chemical characteristics and mode of interaction of the adhesives with enamel and dentinal tissues. Dental adhesives are used for several clinical applications and they can be classified based on the clinical regimen in "etch-and-rinse adhesives" and "self-etch adhesives". Other important considerations concern the different anatomical characteristics of enamel and dentine which are involved in the bonding procedures that have also implications for the technique used as well as for the quality of the bond. Etch-and-rinse adhesive systems generally perform better on enamel than self-etching systems which may be more suitable for bonding to dentine. In order to avoid a possible loss of the restoration, secondary caries or pulp damage due to bacteria penetration or due to cytotoxicity effects of eluted adhesive components, careful consideration of several factors is essential in selecting the suitable bonding procedure and adhesive system for the individual patient situation.

  8. Facial Laceration at Caesarean Section: Experience With Tissue Adhesive

    PubMed Central

    Saraf, Sanjay

    2009-01-01

    Background: The fetal laceration is one of the most commonly identified injuries at the caesarean delivery. The incidence in the literature has been reported to be as high as 3%. The management of such injuries has remained a perplexing problem for both the physician and the parents. Materials and Methods: We present a case of a newborn who accidentally sustained laceration over the face during a caesarean delivery. A review of the literature and management of lacerations with tissue adhesives has been presented. Results: The laceration was successfully managed with tissue adhesive alone with good aesthetic outcome. Conclusion: Topical 2-octylcyanoacrylate tissue adhesives can be an effective alternative therapy for traditional devices for closing simple low-tension lacerations. PMID:19198643

  9. Soft Tissue Tumor Immunohistochemistry Update: Illustrative Examples of Diagnostic Pearls to Avoid Pitfalls.

    PubMed

    Wei, Shi; Henderson-Jackson, Evita; Qian, Xiaohua; Bui, Marilyn M

    2017-08-01

    - Current 2013 World Health Organization classification of tumors of soft tissue arranges these tumors into 12 groups according to their histogenesis. Tumor behavior is classified as benign, intermediate (locally aggressive), intermediate (rarely metastasizing), and malignant. In our practice, a general approach to reaching a definitive diagnosis of soft tissue tumors is to first evaluate clinicoradiologic, histomorphologic, and cytomorphologic features of the tumor to generate some pertinent differential diagnoses. These include the potential line of histogenesis and whether the tumor is benign or malignant, and low or high grade. Although molecular/genetic testing is increasingly finding its applications in characterizing soft tissue tumors, currently immunohistochemistry still not only plays an indispensable role in defining tumor histogenesis, but also serves as a surrogate for underlining molecular/genetic alterations. Objective- To provide an overview focusing on the current concepts in the classification and diagnosis of soft tissue tumors, incorporating immunohistochemistry. This article uses examples to discuss how to use the traditional and new immunohistochemical markers for the diagnosis of soft tissue tumors. Practical diagnostic pearls, summary tables, and figures are used to show how to avoid diagnostic pitfalls. - Data were obtained from pertinent peer-reviewed English-language literature and the authors' first-hand experience as bone and soft tissue pathologists. - -The ultimate goal for a pathologist is to render a specific diagnosis that provides diagnostic, prognostic, and therapeutic information to guide patient care. Immunohistochemistry is integral to the diagnosis and management of soft tissue tumors.

  10. Clinical Presentation of Soft-tissue Infections and its Management: A Study of 100 Cases.

    PubMed

    Singh, Baldev; Singh, Sukha; Khichy, Sudhir; Ghatge, Avinash

    2017-01-01

    Soft-tissue infections vary widely in their nature and severity. A clear approach to the management must allow their rapid identification and treatment as they can be life-threatening. Clinical presentation of soft-tissue infections and its management. A prospective study based on 100 patients presenting with soft-tissue infections was done. All the cases of soft-tissue infections were considered irrespective of age, sex, etiological factors, or systemic disorders. The findings were evaluated regarding the pattern of soft-tissue infections in relation to age and sex, clinical presentation, complications, duration of hospital stay, management, and mortality. The most commonly involved age group was in the range of 41-60 years with male predominance. Abscess formation (45%) was the most common clinical presentation. Type 2 diabetes mellitus was the most common associated comorbid condition. Staphylococcus aureus was the most common culture isolate obtained. The most common complication seen was renal failure. Patients with surgical site infections had maximum duration of stay in the hospital. About 94% of the cases of soft-tissue infections were managed surgically. Mortality was mostly encountered in the cases of complications of cellulitis. Skin and soft-tissue infections are among the most common infections encountered by the emergency physicians. Ignorance, reluctance to treatment, economic constraints, and illiteracy delay the early detection and the initiation of proper treatment. Adequate and timely surgical intervention in most of the cases is of utmost importance to prevent the complications and reduce the mortality.

  11. Risk factors for pedicled flap necrosis in hand soft tissue reconstruction: a multivariate logistic regression analysis.

    PubMed

    Gong, Xu; Cui, Jianli; Jiang, Ziping; Lu, Laijin; Li, Xiucun

    2018-03-01

    Few clinical retrospective studies have reported the risk factors of pedicled flap necrosis in hand soft tissue reconstruction. The aim of this study was to identify non-technical risk factors associated with pedicled flap perioperative necrosis in hand soft tissue reconstruction via a multivariate logistic regression analysis. For patients with hand soft tissue reconstruction, we carefully reviewed hospital records and identified 163 patients who met the inclusion criteria. The characteristics of these patients, flap transfer procedures and postoperative complications were recorded. Eleven predictors were identified. The correlations between pedicled flap necrosis and risk factors were analysed using a logistic regression model. Of 163 skin flaps, 125 flaps survived completely without any complications. The pedicled flap necrosis rate in hands was 11.04%, which included partial flap necrosis (7.36%) and total flap necrosis (3.68%). Soft tissue defects in fingers were noted in 68.10% of all cases. The logistic regression analysis indicated that the soft tissue defect site (P = 0.046, odds ratio (OR) = 0.079, confidence interval (CI) (0.006, 0.959)), flap size (P = 0.020, OR = 1.024, CI (1.004, 1.045)) and postoperative wound infection (P < 0.001, OR = 17.407, CI (3.821, 79.303)) were statistically significant risk factors for pedicled flap necrosis of the hand. Soft tissue defect site, flap size and postoperative wound infection were risk factors associated with pedicled flap necrosis in hand soft tissue defect reconstruction. © 2017 Royal Australasian College of Surgeons.

  12. Serum amyloid P inhibits granulocyte adhesion

    PubMed Central

    2013-01-01

    Background The extravasation of granulocytes (such as neutrophils) at a site of inflammation is a key aspect of the innate immune system. Signals from the site of inflammation upregulate granulocyte adhesion to the endothelium to initiate extravasation, and also enhance granulocyte adhesion to extracellular matrix proteins to facilitate granulocyte movement through the inflamed tissue. During the resolution of inflammation, other signals inhibit granulocyte adhesion to slow and ultimately stop granulocyte influx into the tissue. In a variety of inflammatory diseases such as acute respiratory distress syndrome, an excess infiltration of granulocytes into a tissue causes undesired collateral damage, and being able to reduce granulocyte adhesion and influx could reduce this damage. Results We found that serum amyloid P (SAP), a constitutive protein component of the blood, inhibits granulocyte spreading and granulocyte adhesion to extracellular matrix components. This indicates that in addition to granulocyte adhesion inhibitors that are secreted during the resolution of inflammation, a granulocyte adhesion inhibitor is present at all times in the blood. Although SAP affects adhesion, it does not affect the granulocyte adhesion molecules CD11b, CD62L, CD18, or CD44. SAP also has no effect on the production of hydrogen peroxide by resting or stimulated granulocytes, or N-formyl-methionine-leucine-phenylalanine (fMLP)-induced granulocyte migration. In mice treated with intratracheal bleomycin to induce granulocyte accumulation in the lungs, SAP injections reduced the number of granulocytes in the lungs. Conclusions We found that SAP, a constitutive component of blood, is a granulocyte adhesion inhibitor. We hypothesize that SAP allows granulocytes to sense whether they are in the blood or in a tissue. PMID:23324174

  13. Soft tissues store and return mechanical energy in human running.

    PubMed

    Riddick, R C; Kuo, A D

    2016-02-08

    During human running, softer parts of the body may deform under load and dissipate mechanical energy. Although tissues such as the heel pad have been characterized individually, the aggregate work performed by all soft tissues during running is unknown. We therefore estimated the work performed by soft tissues (N=8 healthy adults) at running speeds ranging 2-5 m s(-1), computed as the difference between joint work performed on rigid segments, and whole-body estimates of work performed on the (non-rigid) body center of mass (COM) and peripheral to the COM. Soft tissues performed aggregate negative work, with magnitude increasing linearly with speed. The amount was about -19 J per stance phase at a nominal 3 m s(-1), accounting for more than 25% of stance phase negative work performed by the entire body. Fluctuations in soft tissue mechanical power over time resembled a damped oscillation starting at ground contact, with peak negative power comparable to that for the knee joint (about -500 W). Even the positive work from soft tissue rebound was significant, about 13 J per stance phase (about 17% of the positive work of the entire body). Assuming that the net dissipative work is offset by an equal amount of active, positive muscle work performed at 25% efficiency, soft tissue dissipation could account for about 29% of the net metabolic expenditure for running at 5 m s(-1). During running, soft tissue deformations dissipate mechanical energy that must be offset by active muscle work at non-negligible metabolic cost. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. SU-C-213-01: 3D Printed Patient Specific Phantom Composed of Bone and Soft Tissue Substitute Plastics for Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ehler, E; Sterling, D; Higgins, P

    Purpose: 3D printed phantoms constructed of multiple tissue approximating materials could be useful in both clinical and research aspects of radiotherapy. This work describes a 3D printed phantom constructed with tissue substitute plastics for both bone and soft tissue; air cavities were included as well. Methods: 3D models of an anonymized nasopharynx patient were generated for air cavities, soft tissues, and bone, which were segmented by Hounsfield Unit (HU) thresholds. HU thresholds were chosen to define air-to-soft tissue boundaries of 0.65 g/cc and soft tissue-to-bone boundaries of 1.18 g/cc based on clinical HU to density tables. After evaluation of severalmore » composite plastics, a bone tissue substitute was identified as an acceptable material for typical radiotherapy x-ray energies, composed of iron and PLA plastic. PET plastic was determined to be an acceptable soft tissue substitute. 3D printing was performed on a consumer grade dual extrusion fused deposition model 3D printer. Results: MVCT scans of the 3D printed heterogeneous phantom were acquired. Rigid image registration of the patient and the 3D printed phantom scans was performed. The average physical density of the soft tissue and bone regions was 1.02 ± 0.08 g/cc and 1.39 ± 0.14 g/cc, respectively, for the patient kVCT scan. In the 3D printed phantom MVCT scan, the average density of the soft tissue and bone was 1.01 ± 0.09 g/cc and 1.44 ± 0.12 g/cc, respectively. Conclusion: A patient specific phantom, constructed of heterogeneous tissue substitute materials was constructed by 3D printing. MVCT of the 3D printed phantom showed realistic tissue densities were recreated by the 3D printing materials. Funding provided by intra-department grant by University of Minnesota Department of Radiation Oncology.« less

  15. Changes of the peri-implant soft tissue thickness after grafting with a collagen matrix

    PubMed Central

    Zafiropoulos, Gregory-George; Deli, Giorgio; Hoffmann, Oliver; John, Gordon

    2016-01-01

    Background: The aim of this study was to determine the treatment outcome of the use of a porcine monolayer collagen matrix (mCM) to increase soft-tissue volume as a part of implant site development. Materials and Methods: Implants were placed in single sites in 27 patients. In the test group, mCM was used for soft-tissue augmentation. No graft was placed in the control group. Soft-tissue thickness (STTh) was measured at the time of surgery (T0) and 6 months postoperatively (T1) at two sites (STTh 1, 1 mm below the gingival margin; STTh 2, 3 mm below the mucogingival margin). Results: Significant increases (P < 0.001) in STTh (STTh 1 = 1.06 mm, 117%; STTh 2 = 0.89 mm, 81%) were observed in the test group. Biopsy results showed angiogenesis and mature connective tissue covered by keratinized epithelium. Conclusions: Within the limitations of this study, it could be concluded that mCM leads to a significant increase of peri-implant soft-tissue thickness, with good histological integration and replacement by soft tissue and may serve as an alternative to connective tissue grafting. PMID:28298828

  16. Use of a Lysine-Derived Urethane Surgical Adhesive as an Alternative to Progressive Tension Sutures in Abdominoplasty Patients: A Cohort Study.

    PubMed

    Spring, Michelle A

    2018-04-07

    Fluid accumulation is a common complication after abdominoplasty procedures, and is typically managed by the placement of post-surgical drains. Progressive tension sutures (PTS) have been shown to be an effective approach to reduce the dead space by point-wise mechanical fixation, allowing for drain-free procedures. Lysine-derived urethane surgical adhesive provides an alternative approach for mechanical fixation and reduction of dead space, and may reduce surgery time compared to PTS. This prospective, controlled, single center clinical study compared progressive tension suture wound closure technique without drains (control) to tissue adhesive wound closure technique without drains (test) during abdominoplasty surgery. The objective was to determine if lysine-derived urethane surgical adhesive is an effective alternative to PTS for drain-free abdominoplasty procedures. Patients undergoing abdominoplasty who met the established inclusion/exclusion criteria were consented and enrolled in the study. Ten PTS (control) cases were performed, followed immediately by ten tissue adhesive (test) cases. Drains were not used in any procedures. Key outcome measures included all major and minor post-surgical complications requiring any intervention, the time to place progressive tension sutures versus time for tissue adhesive application, and number of PTS attachments versus number of adhesive drops applied. Surgeries were completed over an 8-month period. No statistical differences were identified between the two groups with regard to age, BMI, dissection surface area or flap weight. No clinical seroma formation was observed in either group. In the control (PTS) group, two patients developed small areas of dermal closure suture abscess requiring removal of suture material. One control patient developed drainage and fat necrosis thought to be related to PTS above the incision and later required a scar revision. One tissue adhesive patient developed hypertrophic scars of both her breast reduction and abdominoplasty scars requiring additional treatment. The average time to place PTS in the control group was 10.7 minutes (range, 7-18 minutes) and the average number of sutures placed was 16.6 (range, 12-22 sutures). In the test group, the average time to place the tissue adhesive and hold pressure was 5.9 minutes (range 5.5-8.0 minutes). The average number of tissue adhesive drops applied was 69.6 (range: 63-78 drops). In the tissue adhesive group, both the reduction in time for flap adhesion and the increased number of adhesive points were statistically significant when compared to PTS. Lysine-derived urethane surgical adhesive was applied in less time than progressive tension sutures, even after accounting for holding pressure for 5 minutes. The tissue adhesive provided four times the number of attachment points compared to PTS, although the significance of this is not clear. There were no postoperative clinical seromas detected in either group and there were no major complications in either group. Based on these results, the use of lysine-derived urethane surgical adhesive was found to be a safe and effective alternative to progressive tension sutures to reduce seroma formation in drain-free abdominoplasty procedures.

  17. Effect of oxiplex* films (PEO/CMC) on adhesion formation and reformation in rabbit models and on peritoneal infection in a rat model.

    PubMed

    Rodgers, K E; Schwartz, H E; Roda, N; Thornton, M; Kobak, W; diZerega, G S

    2000-04-01

    To assess the efficacy of Oxiplex (FzioMed, Inc., San Luis Obispo, CA) barriers. Film of polyethylene oxide and carboxymethylcellulose (Oxiplex) were tested for strength and tissue adherence. Films were selected for evaluation in models for biocompatability and adherence. Three films were selected for evaluation in efficacy studies, and one was evaluated for effects on bacterial peritonitis. Handling characteristics of Oxiplex film were evaluated via laparoscopy. University laboratory. Rabbits, rats, pigs. Placement of Oxiplex prototypes at the site of injury. Mechanical properties, biocompatibility, tissue adherence, adhesion development, infection potentiation, and device handling. Mechanical tests indicated that tensile strength and elongation were inversely correlated. All films tested had excellent tissue adherence properties. Selected films, based on residence time and biocompatibility, prevented adhesion formation in all animals and were highly efficacious in preventing adhesion reformation. The optimal Oxiplex prototype prevented adhesion reformation in 91% of the animals. This Oxiplex film, dyed to allow visualization, prevented adhesion reformation and did not affect bacterial peritonitis. In a laparoscopic model, the Oxiplex film, delivered in FilmSert forceps, via a 5.0-mm trocar, rapidly unfurled and could be easily applied to tissue with strong adherence. These data show development of an adhesion prevention material that is tissue adherent, can be placed via laparoscopy, and does not affect host resistance.

  18. Therapeutic Angiotensin-(1-7) in Treating Patients With Metastatic Sarcoma That Cannot Be Removed By Surgery

    ClinicalTrials.gov

    2018-02-27

    Bone Cancer; Chondrosarcoma; Clear Cell Sarcoma of the Kidney; Metastatic Osteosarcoma; Ovarian Sarcoma; Recurrent Adult Soft Tissue Sarcoma; Recurrent Osteosarcoma; Recurrent Uterine Sarcoma; Stage III Adult Soft Tissue Sarcoma; Stage III Uterine Sarcoma; Stage IV Adult Soft Tissue Sarcoma; Stage IV Uterine Sarcoma

  19. Ribociclib and Doxorubicin in Treating Patients With Metastatic or Advanced Soft Tissue Sarcomas That Cannot Be Removed by Surgery

    ClinicalTrials.gov

    2018-05-09

    Metastatic Angiosarcoma; Metastatic Epithelioid Sarcoma; Metastatic Fibrosarcoma; Metastatic Leiomyosarcoma; Metastatic Liposarcoma; Metastatic Malignant Peripheral Nerve Sheath Tumor; Metastatic Synovial Sarcoma; Metastatic Undifferentiated Pleomorphic Sarcoma; Myxofibrosarcoma; Pleomorphic Rhabdomyosarcoma; Stage III Soft Tissue Sarcoma; Stage IV Soft Tissue Sarcoma; Undifferentiated (Embryonal) Sarcoma

  20. Soft tissue balancing in total shoulder replacement.

    PubMed

    Mueller, Maike; Hoy, Gregory

    2014-03-01

    Total shoulder arthroplasty is now capable of recreating near anatomic reproduction of native bony shoulder anatomy, but the function and longevity of anatomic shoulder replacement is dependent on a competent soft tissue envelope and adequate motoring of all musculo-tendinous units about the shoulder. Balancing the soft tissues requires understanding of the anatomy and pathology, as well as technical skills. The advent of reverse shoulder biomechanics has brought with it special requirements of understanding of the soft tissue elements still left in the shoulder despite major rotator cuff deficiency.

  1. Soft tissue coverage of the elbow in a developing country.

    PubMed

    Pirela-Cruz, Miguel A; Reddy, Kartheek K; Higgs, Matthew

    2007-09-01

    Two cases that required soft tissue coverage to the anterior aspect of the elbow are presented. A fasciocutaneous intercostal perforator chest wall flap was used for one patient when only skin and fascia coverage was required. A latissimus dorsi myocutaneous flap was used to provide soft tissue coverage and supply motor power for elbow flexion after contracture release in the other. The surgical techniques for each of these flaps are discussed in the context of addressing soft tissue traumatic injuries about the elbow in a developing country with limited resources.

  2. Relevance of infiltration analgesia in pain relief after total knee arthroplasty

    PubMed Central

    Znojek-Tymborowska, Justyna; Kęska, Rafał; Paradowski, Przemysław T.; Witoński, Dariusz

    2013-01-01

    OBJECTIVE: The aim of the study was to assess the effect of different types of anesthesia on pain intensity in early postoperative period. PATIENTS AND METHODS: A total of 87 patients (77 women, 10 men) scheduled for total knee arthroplasty (TKA) were assigned to receive either subarachnoid anesthesia alone or in combination with local soft tissue anesthesia, local soft tissue anesthesia and femoral nerve block and pre-emptive infiltration together with local soft tissue anesthesia. We assessed the pain intensity, opioid consumption, knee joint mobility, and complications of surgery. RESULTS: Subjects with pre-emptive infiltration and local soft tissue anesthesia had lower pain intensity on the first postoperative day compared to those with soft tissue anesthesia and femoral nerve block (P=0.012, effect size 0.68). Subjects who received pre-emptive infiltration and local soft-tissue anesthesia had the greatest range of motion in the operated knee at discharge (mean 90 grades [SD 7], P=0.01 compared to those who received subarachnoid anesthesia alone, and P=0.001 compared to those with subarachnoid together with soft tissue anesthesia). CONCLUSION: Despite the differences in postoperative pain and knee mobility, the results obtained throughout the postoperative period do not enable us to favour neither local nor regional infiltration anesthesia in TKA. Level of Evidence II, Prospective Comparative Study. PMID:24453679

  3. A large parosteal ossifying lipoma of lower limb encircling the femur

    PubMed Central

    2014-01-01

    Introduction Lipoma is a benign soft tissue neoplasm that may contain mesenchymal elements, as a result of metaplastic process. Ossification in benign and malignant soft tissue tumors can also manifest due to metaplastic process. Case presentation A 45 year old woman presented with a large thigh mass. The mass was developed one and a half year ago which insidiously increased in size and was associated with movement restriction. Radiological findings revealed soft tissue neoplasm on antero-medial aspect of thigh encircling the femur and displacing adjacent muscles. Fine trabeculations were seen in neoplasm suggestive of ossification. Excision of the mass was performed and histopathology revealed adipocytes with mature bony trabeculae possessing prominent osteoblastic rimming suggestive of ossifying lipoma. Conclusion It is important to recognize this variant of lipoma as it is associated with a better clinical outcome in contrast to most of the deep seated soft tissue neoplasms. Secondly it should also be differentiated from myositis ossificans and heterologous differentiation in other soft tissue neoplasms. We suggest an algorithmic approach to the diagnosis of ossifying soft tissue neoplasms histopathologically. Mature bony trabeculae with prominent osteoblastic rimming in a soft tissue lesion are due to a metaplastic process and should not be confused with osteosarcoma. PMID:24433545

  4. A mummified duck-billed dinosaur with a soft-tissue cock's comb.

    PubMed

    Bell, Phil R; Fanti, Federico; Currie, Philip J; Arbour, Victoria M

    2014-01-06

    Among living vertebrates, soft tissues are responsible for labile appendages (combs, wattles, proboscides) that are critical for activities ranging from locomotion to sexual display [1]. However, soft tissues rarely fossilize, and such soft-tissue appendages are unknown for many extinct taxa, including dinosaurs. Here we report a remarkable "mummified" specimen of the hadrosaurid dinosaur Edmontosaurus regalis from the latest Cretaceous Wapiti Formation, Alberta, Canada, that preserves a three-dimensional cranial crest (or "comb") composed entirely of soft tissue. Previously, crest function has centered on the hypertrophied nasal passages of lambeosaurine hadrosaurids, which acted as resonance chambers during vocalization [2-4]. The fleshy comb in Edmontosaurus necessitates an alternative explanation most likely related to either social signaling or sexual selection [5-7]. This discovery provides the first view of bizarre, soft-tissue signaling structures in a dinosaur and provides additional evidence for social behavior. Crest evolution within Hadrosaurinae apparently culminated in the secondary loss of the bony crest at the terminal Cretaceous; however, the new specimen indicates that cranial ornamentation was in fact not lost but substituted in Edmontosaurus by a fleshy display structure. It also implies that visual display played a key role in the evolution of hadrosaurine crests and raises the possibility of similar soft-tissue structures among other dinosaurs. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Can plantar soft tissue mechanics enhance prognosis of diabetic foot ulcer?

    PubMed

    Naemi, R; Chatzistergos, P; Suresh, S; Sundar, L; Chockalingam, N; Ramachandran, A

    2017-04-01

    To investigate if the assessment of the mechanical properties of plantar soft tissue can increase the accuracy of predicting Diabetic Foot Ulceration (DFU). 40 patients with diabetic neuropathy and no DFU were recruited. Commonly assessed clinical parameters along with plantar soft tissue stiffness and thickness were measured at baseline using ultrasound elastography technique. 7 patients developed foot ulceration during a 12months follow-up. Logistic regression was used to identify parameters that contribute to predicting the DFU incidence. The effect of using parameters related to the mechanical behaviour of plantar soft tissue on the specificity, sensitivity, prediction strength and accuracy of the predicting models for DFU was assessed. Patients with higher plantar soft tissue thickness and lower stiffness at the 1st Metatarsal head area showed an increased risk of DFU. Adding plantar soft tissue stiffness and thickness to the model improved its specificity (by 3%), sensitivity (by 14%), prediction accuracy (by 5%) and prognosis strength (by 1%). The model containing all predictors was able to effectively (χ 2 (8, N=40)=17.55, P<0.05) distinguish between the patients with and without DFU incidence. The mechanical properties of plantar soft tissue can be used to improve the predictability of DFU in moderate/high risk patients. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Dextran and gelatin based photocrosslinkable tissue adhesive.

    PubMed

    Wang, Tao; Nie, Jun; Yang, Dongzhi

    2012-11-06

    A two-component tissue adhesive based on biocompatible and bio-degradable polymers (oxidized urethane dextran (Dex-U-AD) and gelatin) was prepared and photocrosslinked under the ultraviolet (UV) irradiation. The adhesive could adhere to surface of gelatin, which simulated the human tissue steadily. The structures of above Dex-U-AD were characterized by FTIR, (1)H NMR spectroscopy and XRD. The adhesion property of result products was evaluated by lap-shear test. The maximum adhesion strength could reach to 4.16±0.72 MPa which was significantly higher than that of fibrin glue. The photopolymerization process of Dex-U-AD/gelatin was monitored by real time infrared spectroscopy (RTIR). It took less than 5 min to complete the curing process. The cytotoxicity of Dex-U-AD/gelatin also was evaluated which indicated that Dex-U-AD/gelatin gels were nontoxic to L929 cell. The relationship between all the above-mentioned properties and degree of oxidization of Dex-U-AD was assessed. The obtained products have the potential to serve as tissue adhesive in the future. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. The study on facial soft tissue thickness using Han population in Xinjiang.

    PubMed

    Wang, Jierui; Zhao, Xi; Mi, Congbo; Raza, Iqbal

    2016-09-01

    Facial profile is an important aspect in physical anthropology, forensic science, and cosmetic research. Thus, facial soft tissue measurement technology plays a significant role in facial restoration. A considerable amount of work has investigated facial soft tissue thickness, which significantly varies according to gender, age, and race. However, only few studies have considered the nutritional status of the investigated individuals. Moreover, no sufficient research among Chinese ethnic groups, particularly Xinjiang population in China, is currently available. Hence, the current study investigated the adaptability of facial soft tissue to the underlying hard tissue among young adults of Han population in Xinjiang, China; the analysis was performed on the basis of gender, skeletal class, and body mass index (BMI). Measurements were obtained from the lateral cephalometric radiographs of 256 adults aged 18-26 years old. Differences in soft tissue thickness were observed between genders and among skeletal classes. With regard to gender, significant differences in soft tissue thickness were found at rhinion, glabella, subnasale, stomion, labrale superius, pogonion, and gnathion among different BMI groups. Thus, nutritional status should be considered when reconstructing an individual's facial profile. Results showed that the thinnest and thickest craniofacial soft tissues existed in rhinion and lip regions, respectively. Overall, this research provides valuable data for forensic facial reconstruction and identification of young adults in Xinjiang, China. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. Fibrin tissue adhesive reduces postoperative blood loss in total knee arthroplasty.

    PubMed

    Sabatini, Luigi; Trecci, Andrea; Imarisio, Daniele; Uslenghi, Marco Davide; Bianco, Giuseppe; Scagnelli, Roberto

    2012-09-01

    Blood transfusion is often required in total knee replacement; various methods of blood preservation have been studied. The best solution is to reduce the loss of blood during and after surgery. We designed this study to evaluate the hemostatic efficacy and safety of fibrin tissue adhesive (Quixil) in patients receiving total knee arthroplasty [low contact stress (LCS, DePuy, Warsaw, IN, US) cementless total knee replacement (TKR)] with a prospective, randomized, standard treatment controlled study. Thirty-five patients were randomized to receive treatment with fibrin tissue adhesive (treatment group), and 35 were randomized to be managed with postoperative blood recovery and reinfusion (control group). Blood loss in suction drain, decrease in hemoglobin values, and transfusions were recorded. A significant reduction in apparent total blood loss was detected in the treatment group compared with the control group. There was also a lower decrease in hemoglobin level, although this difference was not significant. When fibrin tissue adhesive was administered, the need for transfusions was lower. No major adverse events were recorded in our series. Fibrin tissue adhesive reduced blood loss in TKR and seemed to significantly reduce the need for blood transfusion. Fibrin tissue adhesive can be an appropriate solution to enhance hemostasis and vessel sealing at the operative site in TKR, in order to reduce blood loss after surgery and the risk of complications.

  9. Impact of adhesive and photoactivation method on sealant integrity and polymer network formation.

    PubMed

    Borges, Boniek Castillo Dutra; Pereira, Fabrício Lopes da Rocha; Alonso, Roberta Caroline Bruschi; Braz, Rodivan; Montes, Marcos Antônio Japiassú Resende; Pinheiro, Isauremi Vieira de Assunção; Santos, Alex José Souza dos

    2012-01-01

    We evaluated the influence of photoactivation method and hydrophobic resin (HR) application on the marginal and internal adaptation, hardness (KHN), and crosslink density (CLD) of a resin-based fissure sealant. Model fissures were created in bovine enamel fragments (n = 10) and sealed using one of the following protocols: no adhesive system + photoactivation of the sealant using continuous light (CL), no adhesive system + photoactivation of the sealant using the soft-start method (SS), HR + CL, or HR + SS. Marginal and internal gaps and KHN were assessed after storage in water for 24 h. The CLD was indirectly assessed by repeating the KHN measurement after 24 h of immersion in 100% ethanol. There was no difference among the samples with regard to marginal or internal adaptation. The KHN and CLD were similar for samples cured using either photoactivation method. Use of a hydrophobic resin prior to placement of fissure sealants and curing the sealant using the soft-start method may not provide any positive influence on integrity or crosslink density.

  10. Advanced Hemophilic Arthropathy: Sensitivity of Soft Tissue Discrimination With Musculoskeletal Ultrasound.

    PubMed

    von Drygalski, Annette; Moore, Randy E; Nguyen, Sonha; Barnes, Richard F W; Volland, Lena M; Hughes, Tudor H; Du, Jiang; Chang, Eric Y

    2018-01-24

    Point-of-care musculoskeletal ultrasound (US) is increasingly used by hemophilia providers to guide management; however, pathologic tissue differentiation with US is uncertain. We sought to determine the extent to which point-of-care musculoskeletal US can identify and discriminate pathologic soft tissue changes in hemophilic arthropathy. Thirty-six adult patients with hemophilia A/B were prospectively enrolled. Point-of-care musculoskeletal US examinations were performed on arthropathic joints (16 knees, 10 ankles, and 10 elbows) using standard views by a musculoskeletal US-trained and certified hematologist, who recorded abnormal intra-articular soft tissue accumulation. Within 3 days, magnetic resonance imaging was performed using conventional and multiecho ultrashort echo time sequences. Soft tissue identification (synovial proliferation with or without hemosiderin, fat, and/or blood products) was performed by a musculoskeletal radiologist. Findings obtained with both imaging modalities were compared and correlated in a blinded fashion. There was perfect agreement between the modalities on the presence of abnormal soft tissue (34 of 36 cases). However, musculoskeletal US was unable to discriminate between coagulated blood, synovium, intrasynovial or extrasynovial fat tissue, or hemosiderin deposits because of wide variations in echogenicity. Musculoskeletal US is valuable for point-of-care imaging to determine the presence of soft tissue accumulation in discrete areas. However, because of limitations of musculoskeletal US in discriminating the nature of pathologic soft tissues and detecting hemosiderin, magnetic resonance imaging will be required if such discrimination is clinically important. © 2018 by the American Institute of Ultrasound in Medicine.

  11. Facile preparation of mussel-inspired polyurethane hydrogel and its rapid curing behavior.

    PubMed

    Sun, Peiyu; Wang, Jing; Yao, Xiong; Peng, Ying; Tu, Xiaoxiong; Du, Pengfei; Zheng, Zhen; Wang, Xinling

    2014-08-13

    A facile method was found to incorporate a mussel-inspired adhesive moiety into synthetic polymers, and mussel mimetic polyurethanes were developed as adhesive hydrogels. In these polymers, a urethane backbone was substituted for the polyamide chain of mussel adhesive proteins, and dopamine was appended to mimic the adhesive moiety of adhesive proteins. A series of mussel mimetic polyurethanes were created through a step-growth polymerization based on hexamethylene diisocyanate as a hard segment, PEG having different molecular weights as a soft segment, and lysine-dopamine as a chain extender. Upon a treatment with Fe(3+), the aqueous mussel mimetic polyurethane solutions can be triggered by pH adjustment to form adhesive hydrogels instantaneously; these materials can be used as injectable adhesive hydrogels. Upon a treatment with NaIO4, the mussel mimetic polyurethane solutions can be cured in a controllable period of time. The successful combination of the unique mussel-inspired adhesive moiety with a tunable polyurethane structure can result in a new kind of mussel-inspired adhesive polymers.

  12. Murine tissues exposed to cytotoxic drugs display altered patterns of Candida albicans adhesion.

    PubMed Central

    López-Ribot, J L; McVay, C S; Chaffin, W L

    1994-01-01

    An ex vivo adhesion assay was used to examine the binding of Candida albicans yeast cells to tissues from mice treated with cytotoxic drugs such as lipopolysaccharide and the clinically used anticancer drugs doxorubicin, cisplatin, and vincristine. No major differences were observed in binding of the fungal cells to liver and kidney tissues from treated or untreated animals. All drug-treated spleens displayed altered patterns of C. albicans adhesion compared with the control group, with yeast cells bound not only to the marginal zone but also to the white and red pulp. Immunostaining for macrophages, which are proposed as the site of normal adhesion, showed no apparent differences between the control and the experimental spleens that could account for the change in adhesion patterns. Scanning electron microscopy images suggested that yeast binding to the white pulp of treated tissue is mediated through fibers, perhaps extracellular matrix components exposed as result of the cytotoxic treatment. Exposure of new attachment sites for C. albicans in treated tissues may facilitate initiation of infection. Images PMID:7927678

  13. Soft tissue grafting to improve implant esthetics

    PubMed Central

    Kassab, Moawia M

    2010-01-01

    Dental implants are becoming the treatment of choice to replace missing teeth, especially if the adjacent teeth are free of restorations. When minimal bone width is present, implant placement becomes a challenge and often resulting in recession and dehiscence around the implant that leads to subsequent gingival recession. To correct such defect, the author turned to soft tissue autografting and allografting to correct a buccal dehiscence around tooth #24 after a malpositioned implant placed by a different surgeon. A 25-year-old woman presented with the chief complaint of gingival recession and exposure of implant threads around tooth #24. The patient received three soft tissue grafting procedures to augment the gingival tissue. The first surgery included a connective tissue graft to increase the width of the keratinized gingival tissue. The second surgery included the use of autografting (connective tissue graft) to coronally position the soft tissue and achieve implant coverage. The third and final surgery included the use of allografting material Alloderm to increase and mask the implant from showing through the gingiva. Healing period was uneventful for the patient. After three surgical procedures, it appears that soft tissue grafting has increased the width and height of the gingiva surrounding the implant. The accomplished thickness of gingival tissue appeared to mask the showing of implant threads through the gingival tissue and allowed for achieving the desired esthetic that the patient desired. The aim of the study is to present a clinical case with soft tissue grafting procedures. PMID:23662087

  14. Optimization and real-time control for laser treatment of heterogeneous soft tissues.

    PubMed

    Feng, Yusheng; Fuentes, David; Hawkins, Andrea; Bass, Jon M; Rylander, Marissa Nichole

    2009-01-01

    Predicting the outcome of thermotherapies in cancer treatment requires an accurate characterization of the bioheat transfer processes in soft tissues. Due to the biological and structural complexity of tumor (soft tissue) composition and vasculature, it is often very difficult to obtain reliable tissue properties that is one of the key factors for the accurate treatment outcome prediction. Efficient algorithms employing in vivo thermal measurements to determine heterogeneous thermal tissues properties in conjunction with a detailed sensitivity analysis can produce essential information for model development and optimal control. The goals of this paper are to present a general formulation of the bioheat transfer equation for heterogeneous soft tissues, review models and algorithms developed for cell damage, heat shock proteins, and soft tissues with nanoparticle inclusion, and demonstrate an overall computational strategy for developing a laser treatment framework with the ability to perform real-time robust calibrations and optimal control. This computational strategy can be applied to other thermotherapies using the heat source such as radio frequency or high intensity focused ultrasound.

  15. Limitation of Cell Adhesion by the Elasticity of the Extracellular Matrix

    PubMed Central

    Nicolas, Alice; Safran, Samuel. A.

    2006-01-01

    Cell/matrix adhesions are modulated by cytoskeletal or external stresses and adapt to the mechanical properties of the extracellular matrix. We propose that this mechanosensitivity arises from the activation of a mechanosensor located within the adhesion itself. We show that this mechanism accounts for the observed directional growth of focal adhesions and the reduction or even cessation of their growth when cells adhere to a soft extracellular matrix. We predict quantitatively that both the elasticity and the thickness of the matrix play a key role in the dynamics of focal adhesions. Two different types of dynamics are expected depending on whether the thickness of the matrix is of order of or much larger than the adhesion size. In the latter situation, we predict that the adhesion region reaches a saturation size that can be tuned by the mechanical properties of the matrix. PMID:16581840

  16. Improving Bone Formation in a Rat Femur Segmental Defect by Controlling Bone Morphogenetic Protein-2 Release

    DTIC Science & Technology

    2011-04-01

    tissue and polymer: mineralized tissue stained dark green, osteoid and collagen bright red, soft tissue pink to light green, and erythrocytes bright...of bone, soft tissue , and polymer, high-resolution digital images were acquired at 1.25 · or 20 · . The area of interest comprising the bone defect...bone, soft tissue , and polymer (when present) within the defect were quantified using Metamorph software (Molecular Devices, Inc.) and were calculated

  17. Biomimetic stratified scaffold design for ligament-to-bone interface tissue engineering.

    PubMed

    Lu, Helen H; Spalazzi, Jeffrey P

    2009-07-01

    The emphasis in the field of orthopaedic tissue engineering is on imparting biomimetic functionality to tissue engineered bone or soft tissue grafts and enabling their translation to the clinic. A significant challenge in achieving extended graft functionality is engineering the biological fixation of these grafts with each other as well as with the host environment. Biological fixation will require re-establishment of the structure-function relationship inherent at the native soft tissue-to-bone interface on these tissue engineered grafts. To this end, strategic biomimicry must be incorporated into advanced scaffold design. To facilitate integration between distinct tissue types (e.g., bone with soft tissues such as cartilage, ligament, or tendon), a stratified or multi-phasic scaffold with distinct yet continuous tissue regions is required to pre-engineer the interface between bone and soft tissues. Using the ACL-to-bone interface as a model system, this review outlines the strategies for stratified scaffold design for interface tissue engineering, focusing on identifying the relevant design parameters derived from an understanding of the structure-function relationship inherent at the soft-to-hard tissue interface. The design approach centers on first addressing the challenge of soft tissue-to-bone integration ex vivo, and then subsequently focusing on the relatively less difficult task of bone-to-bone integration in vivo. In addition, we will review stratified scaffold design aimed at exercising spatial control over heterotypic cellular interactions, which are critical for facilitating the formation and maintenance of distinct yet continuous multi-tissue regions. Finally, potential challenges and future directions in this emerging area of advanced scaffold design will be discussed.

  18. Influence of Abutment Color and Mucosal Thickness on Soft Tissue Color.

    PubMed

    Ferrari, Marco; Carrabba, Michele; Vichi, Alessandro; Goracci, Cecilia; Cagidiaco, Maria Crysanti

    Zirconia (ZrO₂) and titanium nitride (TiN) implant abutments were introduced mainly for esthetic purposes, as titanium's gray color can be visible through mucosal tissues. This study was aimed at assessing whether ZrO₂ and TiN abutments could achieve better esthetics in comparison with titanium (Ti) abutments, regarding the appearance of soft tissues. Ninety patients were included in the study. Each patient was provided with an implant (OsseoSpeed, Dentsply Implant System). A two-stage surgical technique was performed. Six months later, surgical reentry was performed. After 1 week, provisional restorations were screwed onto the implants. After 8 weeks, implant-level impressions were taken and soft tissue thickness was recorded, ranking thin (≤ 2 mm) or thick (≥ 2 mm). Patients were randomly allocated to three experimental groups, based on abutment type: (1) Ti, (2) TiN, and (3) ZrO₂. After 15 weeks, the final restorations were delivered. The mucosal area referring to each abutment was measured for color using a clinical spectrophotometer (Easyshade, VITA); color measurements of the contralateral areas referring to natural teeth were performed at the same time. The data were collected using the Commission Internationale de l'Eclairage (CIE) L*a*b* color system, and ΔE was calculated between peri-implant and contralateral soft tissues. A critical threshold of ΔE = 3.7 was selected. The chi-square test was used to identify statistically significant differences in ΔE between thin and thick mucosal tissues and among the abutment types. Three patients were lost at follow-up. No statistically significant differences were noticed as to the abutment type (P = .966). Statistically significant differences in ΔE were recorded between thick and thin peri-implant soft tissues (P < .001). Only 2 out of 64 patients with thick soft tissues showed a ΔE higher than 3.7: 1 in the TiN group and 1 in the ZrO₂ group. All the patients with thin soft tissues reported color changes that exceeded the critical threshold. The different abutment materials showed comparable results in terms of influence on soft tissue color. Regarding peri-implant soft tissue thickness, the influence of the tested abutments on soft tissue color became clinically relevant for values ≤ 2 mm.

  19. Influence of Microbial Biofilms on the Preservation of Primary Soft Tissue in Fossil and Extant Archosaurs

    PubMed Central

    Peterson, Joseph E.; Lenczewski, Melissa E.; Scherer, Reed P.

    2010-01-01

    Background Mineralized and permineralized bone is the most common form of fossilization in the vertebrate record. Preservation of gross soft tissues is extremely rare, but recent studies have suggested that primary soft tissues and biomolecules are more commonly preserved within preserved bones than had been presumed. Some of these claims have been challenged, with presentation of evidence suggesting that some of the structures are microbial artifacts, not primary soft tissues. The identification of biomolecules in fossil vertebrate extracts from a specimen of Brachylophosaurus canadensis has shown the interpretation of preserved organic remains as microbial biofilm to be highly unlikely. These discussions also propose a variety of potential mechanisms that would permit the preservation of soft-tissues in vertebrate fossils over geologic time. Methodology/Principal Findings This study experimentally examines the role of microbial biofilms in soft-tissue preservation in vertebrate fossils by quantitatively establishing the growth and morphology of biofilms on extant archosaur bone. These results are microscopically and morphologically compared with soft-tissue extracts from vertebrate fossils from the Hell Creek Formation of southeastern Montana (Latest Maastrichtian) in order to investigate the potential role of microbial biofilms on the preservation of fossil bone and bound organic matter in a variety of taphonomic settings. Based on these analyses, we highlight a mechanism whereby this bound organic matter may be preserved. Conclusions/Significance Results of the study indicate that the crystallization of microbial biofilms on decomposing organic matter within vertebrate bone in early taphonomic stages may contribute to the preservation of primary soft tissues deeper in the bone structure. PMID:20967227

  20. Influence of microbial biofilms on the preservation of primary soft tissue in fossil and extant archosaurs.

    PubMed

    Peterson, Joseph E; Lenczewski, Melissa E; Scherer, Reed P

    2010-10-12

    Mineralized and permineralized bone is the most common form of fossilization in the vertebrate record. Preservation of gross soft tissues is extremely rare, but recent studies have suggested that primary soft tissues and biomolecules are more commonly preserved within preserved bones than had been presumed. Some of these claims have been challenged, with presentation of evidence suggesting that some of the structures are microbial artifacts, not primary soft tissues. The identification of biomolecules in fossil vertebrate extracts from a specimen of Brachylophosaurus canadensis has shown the interpretation of preserved organic remains as microbial biofilm to be highly unlikely. These discussions also propose a variety of potential mechanisms that would permit the preservation of soft-tissues in vertebrate fossils over geologic time. This study experimentally examines the role of microbial biofilms in soft-tissue preservation in vertebrate fossils by quantitatively establishing the growth and morphology of biofilms on extant archosaur bone. These results are microscopically and morphologically compared with soft-tissue extracts from vertebrate fossils from the Hell Creek Formation of southeastern Montana (Latest Maastrichtian) in order to investigate the potential role of microbial biofilms on the preservation of fossil bone and bound organic matter in a variety of taphonomic settings. Based on these analyses, we highlight a mechanism whereby this bound organic matter may be preserved. Results of the study indicate that the crystallization of microbial biofilms on decomposing organic matter within vertebrate bone in early taphonomic stages may contribute to the preservation of primary soft tissues deeper in the bone structure.

  1. Hindfoot containment orthosis for management of bone and soft-tissue defects of the heel.

    PubMed

    Johnson, Jeffrey E; Rudzki, Jonas R; Janisse, Erick; Janisse, Dennis J; Valdez, Ray R; Hanel, Douglas P; Gould, John S

    2005-03-01

    Bone, soft-tissue, and nerve deficits of the weightbearing surface of the foot are frequent sequelae from foot trauma or diabetes mellitus and present challenging treatment issues. Injury to the specialized, shock-absorbing, heel-pad tissue containing spirally arranged fat chambers is particularly difficult to manage. Appropriate footwear modifications and shoe inserts for protection of this skin are essential to the long-term management of bone and soft-tissue defects of the heel. This study evaluated the performance of a new custom total contact foot orthosis (Hindfoot Containment Orthosis, HCO) which was designed to contain the soft tissues of the heel, reduce shear forces, redistribute weightbearing load, and accommodate bone or soft-tissue deformity of the heel. Twenty-two patients treated with HCO were retrospectively reviewed. Followup averaged 26 months. The effectiveness of the orthosis was assessed by how well the integrity of the soft tissue was maintained (e.g. the number of ulcerations since dispensing the orthosis), the number of refabrications of the orthosis that were required, and whether or not revision surgery was required. Ten patients had superficial ulcerations. No patient required revision surgery. A total of 62 refabrications of the orthoses in 22 patients were required over a 2-year period. Overall results were good in 17 (77%) patients, fair in four (18%), and poor in one. The HCO is effective for preservation of soft-tissue integrity of the heel pad after bony or soft-tissue injury. Important factors in achieving success with the HCO are patient compliance and periodic monitoring for refabrication of the orthosis to accommodate skeletal growth, change in foot size or shape, and compression or wear of insert materials.

  2. Peri-implant soft tissue colour around titanium and zirconia abutments: a prospective randomized controlled clinical study.

    PubMed

    Cosgarea, Raluca; Gasparik, Cristina; Dudea, Diana; Culic, Bogdan; Dannewitz, Bettina; Sculean, Anton

    2015-05-01

    To objectively determine the difference in colour between the peri-implant soft tissue at titanium and zirconia abutments. Eleven patients, each with two contralaterally inserted osteointegrated dental implants, were included in this study. The implants were restored either with titanium abutments and porcelain-fused-to-metal crowns, or with zirconia abutments and ceramic crowns. Prior and after crown cementation, multi-spectral images of the peri-implant soft tissues and the gingiva of the neighbouring teeth were taken with a colorimeter. The colour parameters L*, a*, b*, c* and the colour differences ΔE were calculated. Descriptive statistics, including non-parametric tests and correlation coefficients, were used for statistical analyses of the data. Compared to the gingiva of the neighbouring teeth, the peri-implant soft tissue around titanium and zirconia (test group), showed distinguishable ΔE both before and after crown cementation. Colour differences around titanium were statistically significant different (P = 0.01) only at 1 mm prior to crown cementation compared to zirconia. Compared to the gingiva of the neighbouring teeth, statistically significant (P < 0.01) differences were found for all colour parameter, either before or after crown cementation for both abutments; more significant differences were registered for titanium abutments. Tissue thickness correlated positively with c*-values for titanium at 1 mm and 2 mm from the gingival margin. Within their limits, the present data indicate that: (i) The peri-implant soft tissue around titanium and zirconia showed colour differences when compared to the soft tissue around natural teeth, and (ii) the peri-implant soft tissue around zirconia demonstrated a better colour match to the soft tissue at natural teeth than titanium. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Examining porous bio-active glass as a potential osteo-odonto-keratoprosthetic skirt material.

    PubMed

    Huhtinen, Reeta; Sandeman, Susan; Rose, Susanna; Fok, Elsie; Howell, Carol; Fröberg, Linda; Moritz, Niko; Hupa, Leena; Lloyd, Andrew

    2013-05-01

    Bio-active glass has been developed for use as a bone substitute with strong osteo-inductive capacity and the ability to form strong bonds with soft and hard tissue. The ability of this material to enhance tissue in-growth suggests its potential use as a substitute for the dental laminate of an osteo-odonto-keratoprosthesis. A preliminary in vitro investigation of porous bio-active glass as an OOKP skirt material was carried out. Porous glass structures were manufactured from bio-active glasses 1-98 and 28-04 containing varying oxide formulation (1-98, 28-04) and particle size range (250-315 μm for 1-98 and 28-04a, 315-500 μm for 28-04b). Dissolution of the porous glass structure and its effect on pH was measured. Structural 2D and 3D analysis of porous structures were performed. Cell culture experiments were carried out to study keratocyte adhesion and the inflammatory response induced by the porous glass materials. The dissolution results suggested that the porous structure made out of 1-98 dissolves faster than the structures made from glass 28-04. pH experiments showed that the dissolution of the porous glass increased the pH of the surrounding solution. The cell culture results showed that keratocytes adhered onto the surface of each of the porous glass structures, but cell adhesion and spreading was greatest for the 98a bio-glass. Cytokine production by all porous glass samples was similar to that of the negative control indicating that the glasses do not induce a cytokine driven inflammatory response. Cell culture results support the potential use of synthetic porous bio-glass as an OOKP skirt material in terms of limited inflammatory potential and capacity to induce and support tissue ingrowth.

  4. Myocardial matrix-polyethylene glycol hybrid hydrogels for tissue engineering

    NASA Astrophysics Data System (ADS)

    Grover, Gregory N.; Rao, Nikhil; Christman, Karen L.

    2014-01-01

    Similar to other protein-based hydrogels, extracellular matrix (ECM) based hydrogels, derived from decellularized tissues, have a narrow range of mechanical properties and are rapidly degraded. These hydrogels contain natural cellular adhesion sites, form nanofibrous networks similar to native ECM, and are biodegradable. In this study, we expand the properties of these types of materials by incorporating poly(ethylene glycol) (PEG) into the ECM network. We use decellularized myocardial matrix as an example of a tissue specific ECM derived hydrogel. Myocardial matrix-PEG hybrids were synthesized by two different methods, cross-linking the proteins with an amine-reactive PEG-star and photo-induced radical polymerization of two different multi-armed PEG-acrylates. We show that both methods allow for conjugation of PEG to the myocardial matrix by gel electrophoresis and infrared spectroscopy. Scanning electron microscopy demonstrated that the hybrid materials still contain a nanofibrous network similar to unmodified myocardial matrix and that the fiber diameter is changed by the method of PEG incorporation and PEG molecular weight. PEG conjugation also decreased the rate of enzymatic degradation in vitro, and increased material stiffness. Hybrids synthesized with amine-reactive PEG had gelation rates of 30 min, similar to the unmodified myocardial matrix, and incorporation of PEG did not prevent cell adhesion and migration through the hydrogels, thus offering the possibility to have an injectable ECM hydrogel that degrades more slowly in vivo. The photo-polymerized radical systems gelled in 4 min upon irradiation, allowing 3D encapsulation and culture of cells, unlike the soft unmodified myocardial matrix. This work demonstrates that PEG incorporation into ECM-based hydrogels can expand material properties, thereby opening up new possibilities for in vitro and in vivo applications.

  5. Nanoparticle flotation collectors--the influence of particle softness.

    PubMed

    Yang, Songtao; Razavizadeh, Bi Bi Marzieh; Pelton, Robert; Bruin, Gerard

    2013-06-12

    The ability of polymeric nanoparticles to promote glass bead and pentlandite (Pn, nickel sulfide mineral) attachment to air bubbles in flotation was measured as a function of the nanoparticle glass transition temperature using six types of nanoparticles based on styrene/N-butylacrylate copolymers. Nanoparticle size, surface charge density, and hydrophobicity were approximately constant over the series. The ability of the nanoparticles to promote air bubble attachment and perform as flotation collectors was significantly greater for softer nanoparticles. We propose that softer nanoparticles were more firmly attached to the glass beads or mineral surface because the softer particles had a greater glass/polymer contact areas and thus stronger overall adhesion. The diameters of the contact areas between polymeric nanoparticles and glass surfaces were estimated with the Young-Laplace equation for soft, liquidlike particles, whereas JKR adhesion theory was applied to the harder polystyrene particles. The diameters of the contact areas were estimated to be more than an order of magnitude greater for the soft particles compared to harder polystyrene particles.

  6. Crack blunting and the strength of soft elastic solids

    NASA Astrophysics Data System (ADS)

    Hui, C.-Y.; Jagota, A.; Bennison, S. J.; Londono, J. D.

    2003-06-01

    When a material is so soft that the cohesive strength (or adhesive strength, in the case of interfacial fracture) exceeds the elastic modulus of the material, we show that a crack will blunt instead of propagating. Large-deformation finite-element model (FEM) simulations of crack initiation, in which the debonding processes are quantified using a cohesive zone model, are used to support this hypothesis. An approximate analytic solution, which agrees well with the FEM simulation, gives additional insight into the blunting process. The consequence of this result on the strength of soft, rubbery materials is the main topic of this paper. We propose two mechanisms by which crack growth can occur in such blunted regions. We have also performed experiments on two different elastomers to demonstrate elastic blunting. In one system, we present some details on a void growth mechanism for ultimate failure, post-blunting. Finally, we demonstrate how crack blunting can shed light on some long-standing problems in the area of adhesion and fracture of elastomers.

  7. Sorafenib in Treating Patients With Metastatic, Locally Advanced, or Recurrent Sarcoma

    ClinicalTrials.gov

    2014-05-07

    Adult Angiosarcoma; Adult Epithelioid Sarcoma; Adult Leiomyosarcoma; Adult Malignant Fibrous Histiocytoma; Adult Neurofibrosarcoma; Adult Synovial Sarcoma; Ovarian Sarcoma; Recurrent Adult Soft Tissue Sarcoma; Recurrent Uterine Sarcoma; Stage III Adult Soft Tissue Sarcoma; Stage III Uterine Sarcoma; Stage IV Adult Soft Tissue Sarcoma; Stage IV Uterine Sarcoma; Uterine Carcinosarcoma; Uterine Leiomyosarcoma

  8. Isolated Limb Perfusion With Melphalan in Treating Patients With Stage IIIB-IV Melanoma or Sarcoma

    ClinicalTrials.gov

    2015-07-22

    Basal Cell Carcinoma of the Skin; Eccrine Carcinoma of the Skin; Recurrent Adult Soft Tissue Sarcoma; Recurrent Melanoma; Recurrent Skin Cancer; Squamous Cell Carcinoma of the Skin; Stage III Adult Soft Tissue Sarcoma; Stage IIIB Melanoma; Stage IIIC Melanoma; Stage IV Adult Soft Tissue Sarcoma; Stage IV Melanoma

  9. Tissue response to five commercially available peritoneal adhesion barriers-A systematic histological evaluation.

    PubMed

    Schmitt, Volker H; Mamilos, Andreas; Schmitt, Christine; Neitzer-Planck, Constanze N E; Rajab, Taufiek K; Hollemann, David; Wagner, Willi; Krämer, Bernhard; Hierlemann, Helmut; James Kirkpatrick, C; Brochhausen, Christoph

    2018-02-01

    Separating wounded serosa by physical barriers is the only clinically approved adjunct for postoperative adhesion prevention. Since the optimal adhesion barrier has not been found, it is essential to improve our pathogenic understanding of adhesion formation and to compare the effects of different barrier materials on tissue and cells. Wistar rats underwent standardized peritoneal damage and were treated either with Seprafilm, Adept, Intercoat, Spraygel, SupraSeal or remained untreated as a control. 14 days postoperatively, the lesions were explanted and histomorphologically analyzed using the European ISO score to evaluate material implants. Striking differences between the material groups were present regarding the inflammation, fibrosis, and foreign body reaction. According to the ISO score, Intercoat and Spraygel were considered as nonirritating to tissue. Adept, Seprafilm, and SupraSeal were assessed as mild-irritating materials. Interestingly, the most effective material in adhesion prevention revealed moderate inflammation accompanied by minor fibrosis. The degree of inflammation to barrier materials does not predict the efficacy in the prevention of adhesions. Histopathological investigations are crucial to improve our understanding of the cellular mechanisms during adhesion formation and elucidate the tissue response to material approaches used in adhesion prevention. This will lead to improved antiadhesive strategies and the development of functional barrier biomaterials. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 598-609, 2018. © 2017 Wiley Periodicals, Inc.

  10. The use of time-of-flight camera for navigating robots in computer-aided surgery: monitoring the soft tissue envelope of minimally invasive hip approach in a cadaver study.

    PubMed

    Putzer, David; Klug, Sebastian; Moctezuma, Jose Luis; Nogler, Michael

    2014-12-01

    Time-of-flight (TOF) cameras can guide surgical robots or provide soft tissue information for augmented reality in the medical field. In this study, a method to automatically track the soft tissue envelope of a minimally invasive hip approach in a cadaver study is described. An algorithm for the TOF camera was developed and 30 measurements on 8 surgical situs (direct anterior approach) were carried out. The results were compared to a manual measurement of the soft tissue envelope. The TOF camera showed an overall recognition rate of the soft tissue envelope of 75%. On comparing the results from the algorithm with the manual measurements, a significant difference was found (P > .005). In this preliminary study, we have presented a method for automatically recognizing the soft tissue envelope of the surgical field in a real-time application. Further improvements could result in a robotic navigation device for minimally invasive hip surgery. © The Author(s) 2014.

  11. Options to avoid the second surgical site: a review of literature.

    PubMed

    Ramachandra, Srinivas Sulugodu; Rana, Ritu; Reetika, Singhal; Jithendra, K D

    2014-09-01

    As esthetics gain importance, periodontal plastic surgical procedures involving soft tissue grafts are becoming commoner both around natural teeth as well as around implants. Periodontal soft tissue grafts are primarily used for the purpose of root coverage and in pre-prosthetic surgery to thicken a gingival site or to improve the crestal volume. Soft tissue grafts are usually harvested from the palate. Periodontal plastic surgical procedures involving soft tissue grafts harvested from the palate have two surgical sites; a recipient site and another donor site. Many patients are apprehensive about the soft tissue graft procedures, especially the creation of the second/donor surgical site in the palate. In the past decade, newer techniques and products have emerged which provide an option for the periodontist/patient to avoid the second surgical site. MucoMatrixX, Alloderm(®), Platelet rich fibrin, Puros(®) Dermis and Mucograft(®) are the various options available to the practicing periodontist to avoid the second surgical site. Use of these soft tissue allografts in an apprehensive patient would decrease patient morbidity and increase patient's acceptance towards periodontal plastic surgical procedures.

  12. [Research on adaptive quasi-linear viscoelastic model for nonlinear viscoelastic properties of in vivo soft tissues].

    PubMed

    Wang, Heng; Sang, Yuanjun

    2017-10-01

    The mechanical behavior modeling of human soft biological tissues is a key issue for a large number of medical applications, such as surgery simulation, surgery planning, diagnosis, etc. To develop a biomechanical model of human soft tissues under large deformation for surgery simulation, the adaptive quasi-linear viscoelastic (AQLV) model was proposed and applied in human forearm soft tissues by indentation tests. An incremental ramp-and-hold test was carried out to calibrate the model parameters. To verify the predictive ability of the AQLV model, the incremental ramp-and-hold test, a single large amplitude ramp-and-hold test and a sinusoidal cyclic test at large strain amplitude were adopted in this study. Results showed that the AQLV model could predict the test results under the three kinds of load conditions. It is concluded that the AQLV model is feasible to describe the nonlinear viscoelastic properties of in vivo soft tissues under large deformation. It is promising that this model can be selected as one of the soft tissues models in the software design for surgery simulation or diagnosis.

  13. Biomechanical properties of the forefoot plantar soft tissue as measured by an optical coherence tomography-based air-jet indentation system and tissue ultrasound palpation system.

    PubMed

    Chao, Clare Y L; Zheng, Yong-Ping; Huang, Yan-Ping; Cheing, Gladys L Y

    2010-07-01

    The forefoot medial plantar area withstand high plantar pressure during locomotion, and is a common site that develops foot lesion problems among elderly people. The aims of the present study were to (1) determine the correlation between the biomechanical properties of forefoot medial plantar soft tissue measured by a newly developed optical coherence tomography-based air-jet indentation system and by tissue ultrasound palpation system, and (2) to compare the biomechanical properties of plantar soft tissues of medial forefoot between a young and old adult group. Thirty healthy subjects were classified as the young or older group. The biomechanical properties of plantar soft tissues measured at the forefoot by the air-jet indentation system and tissue ultrasound palpation system were performed, and the correlation of the findings obtained in the two systems were compared. A strong positive correlation was obtained from the findings in the two systems (r=0.88, P<0.001). The forefoot plantar soft tissue of the older group was significantly stiffer at the second metatarsal head and thinner at both metatarsal heads than that of the young group (all P<0.05). The stiffness coefficient at the second metatarsal head was 28% greater than that at the first metatarsal head in both study groups. Older subjects showed a loss of elasticity and reduced thickness in their forefoot plantar soft tissue, with the second metatarsal head displaying stiffer and thicker plantar tissue than the first metatarsal head. The air-jet indentation system is a useful instrument for characterizing the biomechanical properties of soft tissue. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  14. Digital holography of intracellular dynamics to probe tissue physiology.

    PubMed

    Merrill, Daniel; An, Ran; Turek, John; Nolte, David D

    2015-01-01

    Digital holography provides improved capabilities for imaging through dense tissue. Using a short-coherence source, the digital hologram recorded from backscattered light performs laser ranging that maintains fidelity of information acquired from depths much greater than possible by traditional imaging techniques. Biodynamic imaging (BDI) is a developing technology for live-tissue imaging of up to a millimeter in depth that uses the hologram intensity fluctuations as label-free image contrast and can study tissue behavior in native microenvironments. In this paper BDI is used to investigate the change in adhesion-dependent tissue response in 3D cultures. The results show that increasing density of cellular adhesions slows motion inside tissue and alters the response to cytoskeletal drugs. A clear signature of membrane fluctuations was observed in mid-frequencies (0.1-1 Hz) and was enhanced by the application of cytochalasin-D that degrades the actin cortex inside the cell membrane. This enhancement feature is only observed in tissues that have formed adhesions, because cell pellets initially do not show this signature, but develop this signature only after incubation enables adhesions to form.

  15. Relating cell and tissue mechanics: implications and applications.

    PubMed

    Jakab, Karoly; Damon, Brook; Marga, Françoise; Doaga, Octavian; Mironov, Vladimir; Kosztin, Ioan; Markwald, Roger; Forgacs, Gabor

    2008-09-01

    The Differential Adhesion Hypothesis (DAH) posits that differences in adhesion provide the driving force for morphogenetic processes. A manifestation of differential adhesion is tissue liquidity and a measure for it is tissue surface tension. In terms of this property, DAH correctly predicts global developmental tissue patterns. However, it provides little information on how these patterns arise from the movement and shape changes of cells. We provide strong qualitative and quantitative support for tissue liquidity both in true developmental context and in vitro assays. We follow the movement and characteristic shape changes of individual cells in the course of specific tissue rearrangements leading to liquid-like configurations. Finally, we relate the measurable tissue-liquid properties to molecular entities, whose direct determination under realistic three-dimensional culture conditions is not possible. Our findings confirm the usefulness of tissue liquidity and provide the scientific underpinning for a novel tissue engineering technology.

  16. Comparison of applying particulate demineralized bone matrix (DBM), putty DBM and open flap debridement in periodontal horizontal bone defects. A 12-month longitudinal, multi-centre, triple-blind, split-mouth, randomized, controlled clinical study. Part 2 - evaluation of the interdental soft tissue.

    PubMed

    Kaya, Y; Yalim, M; Bahçecitapar, M; Baloş, K

    2009-07-01

    To date, there have been many studies clinically evaluating periodontal regenerative procedures by the help of routinely used hard and soft tissue parameters; however, these parameters are not capable of assessing interdental soft tissue located above the regenerative periodontal surgery area. The purpose of this study was to assess interproximal soft tissue changes following application of (i) particulate form demineralized bone matrix (DBM), (ii) putty form DBM and (ii) open flap debridement (OFD, control), using modified curtain technique in the treatment of interproximal suprabony (horizontal) defects located in anterior maxillary region, as previously reported. Twenty-five chronic periodontitis patients with 125 interproximal surgery sites (radiologically >or=4 mm horizontal bone defect) were also participate in this second stage of the triple-blind, split mouth, randomized, controlled clinical trial. Surgery sites were assessed by (i) plaque index (PI), (ii) gingival index (GI), (iii) the presence of interdental soft tissue clefts or craters and (iv) the loss of interdental papilla height by using papilla presence index (PPI), during the healing period. At the baseline and 3, 6, 9 and 12 months after the operations, these measurements were repeated. In all groups, there is a significant increase in the prevalence of soft tissue cleft and crater formation (P < 0.01), with increase in PI and GI scores at interdental soft tissue defect areas (P < 0.001), 3 months after the operations. There was also an increase in PPI scores after the operations in all treatment groups (P < 0.01). Three procedures affected the interproximal soft tissues similarly. There was no significant difference among groups in terms of all parameters (P > 0.05). Particulate DBM, putty DBM and OFD demostrated similar interproximal soft tissue changes especially increasing interproximal PI and GI scores in 3 months follow-up.

  17. Can the shell of the green-lipped mussel Perna viridis from the west coast of Peninsular Malaysia be a potential biomonitoring material for Cd, Pb and Zn?

    NASA Astrophysics Data System (ADS)

    Yap, C. K.; Ismail, A.; Tan, S. G.; Abdul Rahim, I.

    2003-07-01

    The distributions of Cd, Pb and Zn in the total soft tissues and total shells of the green-lipped mussel Perna viridis were studied in field collected samples as well as from laboratory experimental samples. The results showed that Cd, Pb and Zn were readily accumulated in the whole shells. In mussels sampled from 12 locations along the west coast of Peninsular Malaysia, the ratios of the shell metals to the soft tissue metals were different at each sampling site. Nevertheless, the Cd and Pb levels in the shells were always higher than those in the soft tissues, while the Zn level was higher in the soft tissues than in the shells. In comparison with soft tissues, the degrees of variability for Pb and Cd concentrations in the shells were lower. The lower degrees of variability and significant ( P<0.05) correlation coefficients of Cd and Pb within the shells support the use of the mussel shell as a suitable biomonitoring material for the two metals rather than the soft tissue since this indicated that there is more precision (lower CV) in the determination of metal concentrations in the shell than in the soft tissue. Experimental work showed that the pattern of depuration in the shell was not similar to that of the soft tissue although their patterns of accumulation were similar. This indicated that the depuration of heavy metals in the shell was not affected by the physiological conditions of the mussels. Although Zn could be regulated by the soft tissue, the incorporated Cd, Pb and Zn remained in the shell matrices. The present results support the use of the total shell of P. viridis as a potential biomonitoring material for long-term contamination of Cd, Pb and Zn.

  18. Non Lipomatous Benign Lesions Mimicking Soft-tissue Sarcomas: A Pictorial Essay.

    PubMed

    Coran, Alessandro; Orsatti, Giovanna; Crimì, Filippo; Rastrelli, Marco; DI Maggio, Antonio; Ponzoni, Alberto; Attar, Shady; Stramare, Roberto

    2018-01-01

    The incidental finding of soft tissue masses is a challenge for the radiologist. Benign and malignant lesions can be differentiated relying on patient history, symptoms and mostly with the help of imaging. Ultrasound (US), computed tomography (CT) and magnetic resonance imaging (MRI) become fundamental in order to distinguish these lesions but the radiologist needs to know the main characteristics of benign soft tissue masses and sarcomas. Herein, we present a pictorial review of lesions mimicking soft tissue sarcomas features. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  19. Rate-dependent elastic hysteresis during the peeling of pressure sensitive adhesives.

    PubMed

    Villey, Richard; Creton, Costantino; Cortet, Pierre-Philippe; Dalbe, Marie-Julie; Jet, Thomas; Saintyves, Baudouin; Santucci, Stéphane; Vanel, Loïc; Yarusso, David J; Ciccotti, Matteo

    2015-05-07

    The modelling of the adherence energy during peeling of Pressure Sensitive Adhesives (PSA) has received much attention since the 1950's, uncovering several factors that aim at explaining their high adherence on most substrates, such as the softness and strong viscoelastic behaviour of the adhesive, the low thickness of the adhesive layer and its confinement by a rigid backing. The more recent investigation of adhesives by probe-tack methods also revealed the importance of cavitation and stringing mechanisms during debonding, underlining the influence of large deformations and of the related non-linear response of the material, which also intervenes during peeling. Although a global modelling of the complex coupling of all these ingredients remains a formidable issue, we report here some key experiments and modelling arguments that should constitute an important step forward. We first measure a non-trivial dependence of the adherence energy on the loading geometry, namely through the influence of the peeling angle, which is found to be separable from the peeling velocity dependence. This is the first time to our knowledge that such adherence energy dependence on the peeling angle is systematically investigated and unambiguously demonstrated. Secondly, we reveal an independent strong influence of the large strain rheology of the adhesives on the adherence energy. We complete both measurements with a microscopic investigation of the debonding region. We discuss existing modellings in light of these measurements and of recent soft material mechanics arguments, to show that the adherence energy during peeling of PSA should not be associated to the propagation of an interfacial stress singularity. The relevant deformation mechanisms are actually located over the whole adhesive thickness, and the adherence energy during peeling of PSA should rather be associated to the energy loss by viscous friction and by rate-dependent elastic hysteresis.

  20. Cross-sectional evaluation of the prevalence and factors associated with soft tissue scarring after the removal of miniscrews.

    PubMed

    Jung, Sung-ah; Choi, Yoon Jeong; Lee, Dong-Won; Kim, Kyung-Ho; Chung, Chooryung J

    2015-05-01

    To investigate the prevalence of distinguishable soft tissue scarring after the removal of temporary anchorage devices (TADs) such as orthodontic miniscrews and to analyze the factors associated with scar formation. The prevalence of soft tissue scarring in 66 patients (202 miniscrew removal sites) was clinically investigated at least 1 year after miniscrew removal. To determine the clinical factors associated with soft tissue scar formation, miniscrew stability; host factors including age, gender, and gingival biotype; and miniscrew-related factors such as insertion site, vertical position, and insertion period were evaluated. The prevalence of a distinguishable scar remaining at least 1 year after miniscrew removal was 44.6%. Patients with flat gingiva showed a significantly higher prevalence of soft tissue scar formation than did those with pronounced scalloped gingiva (P < .05). Maxillary buccal removal sites showed a significantly higher prevalence of soft tissue scar formation than did those in the mandible or palatal slope (P < .05). Miniscrew sites at the alveolar mucosa showed a significantly lower prevalence of soft tissue scar formation than did those in the mucogingival junction or the attached gingiva (P < .01). The prevalence of distinguishable scarring after miniscrew removal was fairly high. On the basis of our results, patients with flat gingiva and buccal interdental gingival insertion sites are more susceptible to scar formation.

  1. Influence of anatomical, physical, and mechanical properties of diffuse-porous hardwoods on moisture durability of bonded assemblies

    Treesearch

    Daniel J. Yelle; Ashley M. Stirgus

    2016-01-01

    Studying wood adhesive bond durability is challenging because wood is highly variable and heterogeneous at all length scales. In this study, three North American diffuse-porous hardwoods (hard maple, soft maple, and basswood) and their adhesively bonded as-semblies were exposed to wet and dry cyclic tests. Then, their den-sity differences were related to bond...

  2. Influence of abutment material on peri-implant soft tissues in anterior areas with thin gingival biotype: a multicentric prospective study.

    PubMed

    Lops, Diego; Stellini, Edoardo; Sbricoli, Luca; Cea, Niccolò; Romeo, Eugenio; Bressan, Eriberto

    2017-10-01

    The aim of the present clinical trial was to analyze, through spectrophotometric digital technology, the influence of the abutment material on the color of the peri-implant soft tissue in patients with thin gingival biotype. Thirty-seven patients received an endosseous dental implant in the anterior maxilla. At time of each definitive prosthesis delivery, an all-ceramic crown has been tried on gold, titanium and zirconia abutment. Peri-implant soft-tissue color has been measured through a spectrophotometer after the insertion of each single abutment. Also facial peri-implant soft-tissue thickness was measured at the level of the implant neck through a caliper. A specific software has been utilized to identify a standardized tissue area and to collect the data before the statistical analysis in Lab* color space. ΔE parameters of the selected abutments were tested for correlation with mucosal thickness. Pearson correlation test was used. Only 15 patients met the study inclusion criteria on peri-implant soft-tissue thickness. Peri-implant soft-tissue color was different from that around natural teeth, no matter which type of restorative material was selected. Measurements regarding all the abutments were above the critical threshold of ΔE 8.74 for intraoral color distinction by the naked eye. The ΔE mean values of gold and zirconium abutments were similar (11.43 and 11.37, respectively) and significantly lower (P = 0.03 and P = 0.04, respectively) than the titanium abutment (13.55). In patients with a facial soft-tissue thickness ≤2 mm, the ΔE mean value of gold and zirconia abutments was significantly lower than that of titanium abutments (P = 0.03 and P = 0.04, respectively) and much more close to the reference threshold of 8.74. For peri-implant soft tissue of ≤2 mm, gold or zirconia abutments could be selected in anterior areas treatment. Moreover, the thickness of the peri-implant soft tissue seemed to be a crucial factor in the abutment impact on the color of soft tissues with a thickness of ≤2 mm. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. In vivo characterization of Hyalonect, a novel biodegradable surgical mesh.

    PubMed

    Rhodes, Nicholas P; Hunt, John A; Longinotti, Cristina; Pavesio, Alessandra

    2011-06-01

    Musculoskeletal reconstructive surgery often requires removal of significant quantities of bone tissue, such as the periosteum, causing critical problems following surgery like friction between different tissues and adhesion of soft tissues to the underlying bone. We studied the long-term host response and closure of large bone defects for periosteal reconstruction using Hyalonect, a novel membrane comprising knitted fibers of esterified hyaluronan, (HYAFF11). For biological characterization, 162 rats were used in a defect model in which a section of the dorsal muscular fascia was removed, and the membrane behavior observed over 540 d using conventional histology, with sham operated rats as controls. In addition, Hyalonect was used to cover defects made in the humeri of 7 dogs, filled with a variety of conventional bone filling compounds, and the regeneration process observed after 6 wks using histology. Low levels of inflammation were observed in the dorsal muscle fascia defect model, with cellular colonization of the mesh by 30 d, vascularization by 120 days, matrix fiber organization by 270 d, and the appearance of connective tissue identical to the surrounding tissue between 365 and 540 d, without the formation of fibrotic tissue. In addition, Hyalonect was shown to allow the regeneration of bone within the humeral defects whilst preventing fibrotic tissue in-growth, and allowing regeneration of tissue which, by 6 wk, had begun to resemble natural periosteal tissue. Hyalonect is suitable for improving the outcome of the final phases of orthopedic and trauma reconstructive surgical procedures, especially in the reconstruction of periosteal tissue. Copyright © 2011. Published by Elsevier Inc.

  4. Bilayer Poly(Lactic-co-glycolic acid)/Nano-Hydroxyapatite Membrane with Barrier Function and Osteogenesis Promotion for Guided Bone Regeneration

    PubMed Central

    Fu, Li; Wang, Zhanfeng; Dong, Shujun; Cai, Yan; Ni, Yuxin; Zhang, Tianshou; Wang, Lin; Zhou, Yanmin

    2017-01-01

    Guided bone regeneration (GBR) is one such treatment that reconstructs neo-bone tissue by using a barrier membrane to prevent the invasion of soft tissue and to create a space for guiding new bone growth into the bone defect. Herein, we report a novel functionally graded bilayer membrane (FGBM) for GBR application. To fabricate the novel membrane, the composites of poly(lactic-co-glycolic acid) and nano-hydroxyapatite were prepared by phase inversion for the dense layer and by electrospinning for another porous layer, and their corresponding properties were evaluated including surface morphology, mechanics, degradability, cell barrier function, and in vitro osteogenic bioactivity. The results showed that PLGA with 5% nHA in dense layer could meet the requirement of mechanical strength and have excellent barrier function even on condition of post-degradation. Furthermore, PLGA with 30% nHA in porous layer could achieve the good physical and chemical properties. In addition, 30% nHA incorporation would enhance the in vitro mineralization, and have superior capabilities of cell adhesion, proliferation and differentiation compared to other groups. Therefore, the designed FGBM could potentially serve as a barrier for preferential tissue ingrowth and achieve a desirable therapeutic result for bone tissue regeneration. PMID:28772618

  5. Elevated expression in situ of selectin and immunoglobulin superfamily type adhesion molecules in retroocular connective tissues from patients with Graves' ophthalmopathy.

    PubMed Central

    Heufelder, A E; Bahn, R S

    1993-01-01

    Activation of certain adhesion molecules within vascular endothelium and the surrounding extravascular space is a critical event in the recruitment and targeting of an inflammatory response or autoimmune attack to a particular tissue site. We have recently demonstrated that the adhesion of lymphocytes to cultured retroocular fibroblasts obtained from patients with Graves' ophthalmopathy (GO) is mediated predominantly by the interaction of lymphocyte function-associated antigen-1 (LFA-1), expressed on lymphocytes, with intercellular adhesion molecule-1 (ICAM-1), expressed by these cells following exposure to interferon-gamma (IFN-gamma), tumour necrosis factor-alpha (TNF-alpha), IL-1 alpha or purified thyroid-stimulating immunoglobulins. We now report the expression and localization in situ of several adhesion molecules, ICAM-1, endothelial leucocyte adhesion molecule-1 (ELAM-1), vascular cell adhesion molecule-1 (VCAM-1), and LFA-3 in retroocular tissues derived from patients with severe GO (n = 4) and normal individuals (n = 3). Serial cryostat sections of tissue specimens were processed for immunoperoxidase staining using various MoAbs against ICAM-1, ELAM-1, VCAM-1 and LFA-3. In addition, consecutive sections were stained with MoAbs against LFA-1, CD45RO (UCHL-1)DR-human leucocyte antigen (HLA-DR), CD11b/CD18 (Mac-1), and CD11c/CD18 (p150,95). In GO-retroocular tissues, strong immunoreactivity for ICAM-1 and LFA-3 was detected in blood vessels (> 90%), in perimysial fibroblasts surrounding extraocular muscle fibres, and in connective tissue distinct from extraocular muscle. No ICAM-1 or LFA-3 immunoreactivity was present in extraocular muscle cells themselves. ICAM-1 and LFA-3 immunoreactivity in normal tissues was minimal or absent both in connective and muscle tissues. Vascular endothelium was strongly positive for ELAM-1 and VCAM-1 in GO-retroocular tissues, while VCAM-1 immunoreactivity was minimal (< 5% of blood vessels) and ELAM-1 immunoreactivity was generally absent in normal retroocular tissue. LFA-1-expressing, activated mononuclear cells and memory T lymphocytes (CD3+/CD45RO+) were only detected in GO-retrocular tissues, and were mainly localized around blood vessels and in areas of ICAM-1-expressing connective and perimysial tissue. HLA-DR expression was restricted to GO-tissue specimens, with strong immunoreactivity detected in blood vessels, macrophages and connective tissue and perimysial fibroblasts. No HLA-DR was detectable in extraocular muscle cells. In conclusion, infiltration of the orbit in GO by mononuclear cells, and their targeting within the orbit, may depend upon the coordinate expression of certain adhesion and MHC molecules.(ABSTRACT TRUNCATED AT 400 WORDS) Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 PMID:7680294

  6. Biological characterization of soft tissue sarcomas.

    PubMed

    Hayashi, Takuma; Horiuchi, Akiko; Sano, Kenji; Kanai, Yae; Yaegashi, Nobuo; Aburatani, Hiroyuki; Konishi, Ikuo

    2015-12-01

    Soft tissue sarcomas are neoplastic malignancies that typically arise in tissues of mesenchymal origin. The identification of novel molecular mechanisms leading to mesenchymal transformation and the establishment of new therapies and diagnostic biomarker has been hampered by several critical factors. First, malignant soft tissue sarcomas are rarely observed in the clinic with fewer than 15,000 newly cases diagnosed each year in the United States. Another complicating factor is that soft tissue sarcomas are extremely heterogeneous as they arise in a multitude of tissues from many different cell lineages. The scarcity of clinical materials coupled with its inherent heterogeneity creates a challenging experimental environment for clinicians and scientists. Faced with these challenges, there has been extremely limited advancement in clinical treatment options available to patients as compared to other malignant tumours. In order to glean insight into the pathobiology of soft tissue sarcomas, scientists are now using mouse models whose genomes have been specifically tailored to carry gene deletions, gene amplifications, and somatic mutations commonly observed in human soft tissue sarcomas. The use of these model organisms has been successful in increasing our knowledge and understanding of how alterations in relevant oncogenic and/or tumour suppressive signal cascades, i.e., interferon-γ (IFN-γ), tumour protein 53 (TP53) and/or retinoblastoma (RB) pathway directly impact sarcomagenesis. It is the goal of many in the physiological community that the use of several mouse models will serve as powerful in vivo tools for further understanding of sarcomagenesis and potentially identify new diagnostic biomarker and therapeutic strategies against human soft tissue sarcomas.

  7. Prevalence, Type and Etiology of Dental and Soft Tissue Injuries in Children in Croatia.

    PubMed

    Škaričić, Josip; Vuletić, Marko; Hrvatin, Sandra; Jeličić, Jesenka; Čuković-Bagić, Ivana; Jurić, Hrvoje

    2016-06-01

    The prevalence, type and etiology of dental and soft tissue injuries and relationship between the time of arrival and sustaining soft tissue injury were analyzed in this retrospective study conducted at the Department of Pediatric Dentistry, University Dental Clinic in Zagreb, Croatia, during the 2010-2014 period using documentation on 447 patients (264 male and 183 female) aged 1-16 years with injuries of primary and permanent teeth. The highest prevalence of traumatic dental injury (TDI) was found in the 7-12 age group and maxillary central incisors were most frequently affected (80.9%) in both primary and permanent dentitions. Enamel-dentin fracture without pulp exposure (31.9%) was the most common TDI of dental hard tissue in both dentitions, whereas subluxation (27.3%) was the most common periodontal tissue injury type. The most frequent location, cause and seasonal variation of trauma were at home, falling and spring. Soft tissue injuries were observed in 203 (45.4%) patients. Soft tissue injuries were less likely when fewer teeth were traumatized (p<0.001). Comparison of children with and without soft tissue injuries yielded a statistically significant difference in the time to arrival between primary and permanent teeth (p<0.01). Because soft tissue injuries include bleeding and clinical presentation appears more dramatic, the time elapsed between injury and initial treatment was shorter than in non-bleeding injuries, pointing to the need of education focused on parents and school teachers regarding the importance of immediate therapy for both bleeding and non-bleeding TDIs.

  8. Estimation of the viscous properties of skin and subcutaneous tissue in uniaxial stress relaxation tests.

    PubMed

    Wu, John Z; Cutlip, Robert G; Welcome, Daniel; Dong, Ren G

    2006-01-01

    Knowledge of viscoelastic properties of soft tissues is essential for the finite element modelling of the stress/strain distributions in finger-pad during vibratory loading, which is important in exploring the mechanism of hand-arm vibration syndrome. In conventional procedures, skin and subcutaneous tissue have to be separated for testing the viscoelastic properties. In this study, a novel method has been proposed to simultaneously determine the viscoelastic properties of skin and subcutaneous tissue in uniaxial stress relaxation tests. A mathematical approach has been derived to obtain the creep and relaxation characteristics of skin and subcutaneous tissue using uniaxial stress relaxation data of skin/subcutaneous composite specimens. The micro-structures of collagen fiber networks in the soft tissue, which underline the tissue mechanical characteristics, will be intact in the proposed method. Therefore, the viscoelastic properties of soft tissues obtained using the proposed method would be more physiologically relevant than those obtained using the conventional method. The proposed approach has been utilized to measure the viscoelastic properties of soft tissues of pig. The relaxation curves of pig skin and subcutaneous tissue obtained in the current study agree well with those in literature. Using the proposed approach, reliable material properties of soft tissues can be obtained in a cost- and time-efficient manner, which simultaneously improves the physiological relevance.

  9. Hydroxyapatite nanobelt/polylactic acid Janus membrane with osteoinduction/barrier dual functions for precise bone defect repair.

    PubMed

    Ma, Baojin; Han, Jing; Zhang, Shan; Liu, Feng; Wang, Shicai; Duan, Jiazhi; Sang, Yuanhua; Jiang, Huaidong; Li, Dong; Ge, Shaohua; Yu, Jinghua; Liu, Hong

    2018-04-15

    Controllable osteoinduction maintained in the original defect area is the key to precise bone repair. To meet the requirement of precise bone regeneration, a hydroxyapatite (HAp) nanobelt/polylactic acid (PLA) (HAp/PLA) Janus membrane has been successfully prepared in this study by coating PLA on a paper-like HAp nanobelt film by a casting-pervaporation method. The Janus membrane possesses dual functions: excellent osteoinduction from the hydrophilic HAp nanobelt side and barrier function originating from the hydrophobic PLA film. The cell viability and osteogenic differentiation ability of human adipose-derived stem cells (hADSCs) on the Janus membrane were assessed. The in vitro experimental results prove that the HAp nanobelt side presents high cell viability and efficient osteoinduction without any growth factor and that the PLA side can prohibit cell attachment. The in vivo repair experiments on a rat mandible defect model prove that the PLA side can prevent postoperative adhesion between bone and adjacent soft tissues. Most importantly, the HAp side has a strong ability to promote defect repair and bone regeneration. Therefore, the HAp/PLA Janus membrane will have wide applications as a kind of tissue engineering material in precise bone repair because of its unique dual osteoinduction/barrier functions, biocompatibility, low cost, and its ability to be mass-produced. Precise bone defect repair to keeping tissue integrity and original outline shape is a very important issue for tissue engineering. Here, we have designed and prepared a novel HAp/PLA Janus membrane using a casting-pervaporation method to form a layer of PLA film on paper-like HAp nanobelt film. HAp nanobelt side of the Janus membrane can successfully promote osteogenic differentiation. PLA side of the Janus membrane exhibits good properties as a barrier for preventing the adhesion of cells in vitro. Mandible repair experiments in vivo have shown that the HAp/PLA Janus membrane can promote rat mandible repair on the HAp side and can successfully prevent postoperative adhesion on the PLA side at the same time. Therefore, the HAp/PLA Janus membrane with its osteoinduction/barrier dual functions can be applied to repair bone defect precisely. Copyright © 2018 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  10. Combination of Collagen Barrier Membrane with Enamel Matrix Derivative-Liquid Improves Osteoblast Adhesion and Differentiation.

    PubMed

    Miron, Richard J; Fujioka-Kobayashi, Masako; Buser, Daniel; Zhang, Yufeng; Bosshardt, Dieter D; Sculean, Anton

    Collagen barrier membranes were first introduced to regenerative periodontal and oral surgery to prevent fast ingrowing soft tissues (ie, epithelium and connective tissue) into the defect space. More recent attempts have aimed at combining collagen membranes with various biologics/growth factors to speed up the healing process and improve the quality of regenerated tissues. Recently, a new formulation of enamel matrix derivative in a liquid carrier system (Osteogain) has demonstrated improved physico-chemical properties for the adsorption of enamel matrix derivative to facilitate protein adsorption to biomaterials. The aim of this pioneering study was to investigate the use of enamel matrix derivative in a liquid carrier system in combination with collagen barrier membranes for its ability to promote osteoblast cell behavior in vitro. Undifferentiated mouse ST2 stromal bone marrow cells were seeded onto porcine-derived collagen membranes alone (control) or porcine membranes + enamel matrix derivative in a liquid carrier system. Control and enamel matrix derivative-coated membranes were compared for cell recruitment and cell adhesion at 8 hours; cell proliferation at 1, 3, and 5 days; and real-time polymerase chain reaction (PCR) at 3 and 14 days for genes encoding Runx2, collagen1alpha2, alkaline phosphatase, and bone sialoprotein. Furthermore, alizarin red staining was used to investigate mineralization. A significant increase in cell adhesion was observed at 8 hours for barrier membranes coated with enamel matrix derivative in a liquid carrier system, whereas no significant difference could be observed for cell proliferation or cell recruitment. Enamel matrix derivative in a liquid carrier system significantly increased alkaline phosphatase mRNA levels 2.5-fold and collagen1alpha2 levels 1.7-fold at 3 days, as well as bone sialoprotein levels twofold at 14 days postseeding. Furthermore, collagen membranes coated with enamel matrix derivative in a liquid carrier system demonstrated a sixfold increase in alizarin red staining at 14 days when compared with collagen membrane alone. The combination of enamel matrix derivative in a liquid carrier system with a barrier membrane significantly increased cell attachment, differentiation, and mineralization of osteoblasts in vitro. Future animal testing is required to fully characterize the additional benefits of combining enamel matrix derivative in a liquid carrier system with a barrier membrane for guided bone or tissue regeneration.

  11. Chronic ankle pain and fibrosis successfully treated with a new noninvasive augmented soft tissue mobilization technique (ASTM): a case report.

    PubMed

    Melham, T J; Sevier, T L; Malnofski, M J; Wilson, J K; Helfst, R H

    1998-06-01

    This clinical case report demonstrates the clinical effectiveness of a new form of soft tissue mobilization in the treatment of excessive connective tissue fibrosis (scar tissue) around an athlete's injured ankle. The scar tissue was causing the athlete to have pain with activity, pain on palpation of the ankle, decreased range of motion, and loss of function. Surgery and several months of conventional physical therapy failed to alleviate the athlete's symptoms. As a final resort, augmented soft tissue mobilization (ASTM) was administered. ASTM is an alternative nonsurgical treatment modality that is being researched at Performance Dynamics (Muncip, IN). ASTM is a process that uses ergonomically designed instruments that assist therapists in the rapid localization and effective treatment of areas exhibiting excessive soft tissue fibrosis. This is followed by a stretching and strengthening program. Upon the completion of 6 wk of ASTM therapy, the athlete had no pain and had regained full range of motion and function. This case report is an example of how a noninvasive augmented form of soft tissue mobilization (ASTM) demonstrated impressive clinical results in treating a condition caused by connective tissue fibrosis.

  12. Traumatic hallux varus repair utilizing a soft-tissue anchor: a case report.

    PubMed

    Labovitz, J M; Kaczander, B I

    2000-01-01

    Hallux varus is usually iatrogenic in nature; however, congenital and acquired etiologies have been described in the literature. The authors present a case of traumatic hallux varus secondary to rupture of the adductor tendon. Surgical correction was performed using a soft tissue anchor for maintenance of the soft tissues utilized for repair.

  13. 75 FR 9422 - Orthopaedic and Rehabilitation Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-02

    ... repair of soft tissue injuries of the medial meniscus. In repairing and reinforcing medial meniscal... zone of the meniscus to provide sufficient vascularization. The CS reinforces soft tissue and provides a resorbable scaffold that is replaced by the patient's own soft tissue. The CS is not a prosthetic...

  14. Hydroxyapatite-coated double network hydrogel directly bondable to the bone: Biological and biomechanical evaluations of the bonding property in an osteochondral defect.

    PubMed

    Wada, Susumu; Kitamura, Nobuto; Nonoyama, Takayuki; Kiyama, Ryuji; Kurokawa, Takayuki; Gong, Jian Ping; Yasuda, Kazunori

    2016-10-15

    We have developed a novel hydroxyapatite (HAp)-coated double-network (DN) hydrogel (HAp/DN gel). The purpose of this study was to determine details of the cell and tissue responses around the implanted HAp/DN gel and to determine how quickly and strongly the HAp/DN gel bonds to the bone in a rabbit osteochondral defect model. Immature osteoid tissue was formed in the space between the HAp/DN gel and the bone at 2weeks, and the osteoid tissue was mineralized at 4weeks. The push-out load of the HAp/DN gel averaged 37.54N and 42.15N at 4 and 12weeks, respectively, while the push-out load of the DN gel averaged less than 5N. The bonding area of the HAp/DN gel to the bone was above 80% by 4weeks, and above 90% at 12weeks. This study demonstrated that the HAp/DN gel enhanced osseointegration at an early stage after implantation. The presence of nanoscale structures in addition to osseointegration of HAp promoted osteoblast adhesion onto the surface of the HAp/DN gel. The HAp/DN gel has the potential to improve the implant-tissue interface in next-generation orthopaedic implants such as artificial cartilage. Recent studies have reported the development of various hydrogels that are sufficiently tough for application as soft supporting tissues. However, fixation of hydrogels on bone surfaces with appropriate strength is a great challenge. We have developed a novel, tough hydrogel hybridizing hydroxyapatite (HAp/DN gel), which is directly bondable to the bone. The present study demonstrated that the HAp/DN gel enhanced osseointegration in the early stage after implantation. The presence of nanoscale structures in addition to the osseointegration ability of hydroxyapatite promoted osteoblast adhesion onto the surface of the HAp/DN gel. The HAp/DN gel has the potential to improve the implant-tissue interface in next-generation orthopaedic implants such as artificial cartilage. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  15. Mechanically enhanced nested-network hydrogels as a coating material for biomedical devices.

    PubMed

    Wang, Zhengmu; Zhang, Hongbin; Chu, Axel J; Jackson, John; Lin, Karen; Lim, Chinten James; Lange, Dirk; Chiao, Mu

    2018-04-01

    Well-organized composite formations such as hierarchical nested-network (NN) structure in bone tissue and reticular connective tissue present remarkable mechanical strength and play a crucial role in achieving physical and biological functions for living organisms. Inspired by these delicate microstructures in nature, an analogous scaffold of double network hydrogel was fabricated by creating a poly(2-hydroxyethyl methacrylate) (pHEMA) network in the porous structure of alginate hydrogels. The resulting hydrogel possessed hierarchical NN structure and showed significantly improved mechanical strength but still maintained high elasticity comparable to soft tissues due to a mutual strengthening effect between the two networks. The tough hydrogel is also self-lubricated, exhibiting a surface friction coefficient comparable with polydimethylsiloxane (PDMS) substrates lubricated by a commercial aqueous lubricant (K-Y Jelly) and other low surface friction hydrogels. Additional properties of this hydrogel include high hydrophilicity, good biocompatibility, tunable cell adhesion and bacterial resistance after incorporation of silver nanoparticles. Firm bonding of the hydrogel on silicone substrates could be achieved through facile chemical modification, thus enabling the use of this hydrogel as a versatile coating material for biomedical applications. In this study, we developed a tough hydrogel by crosslinking HEMA monomers in alginate hydrogels and forming a well-organized structure of hierarchical nested network (NN). Different from most reported stretchable alginate-based hydrogels, the NN hydrogel shows higher compressive strength but retains comparable softness to alginate counterparts. This work further demonstrated the good integration of the tough hydrogel with silicone substrates through chemical modification and micropillar structures. Other properties including surface friction, biocompatibility and bacterial resistance were investigated and the hydrogel shows a great promise as a versatile coating material for biomedical applications. Copyright © 2018 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  16. Eccentric Exercise Versus Eccentric Exercise and Soft Tissue Treatment (Astym) in the Management of Insertional Achilles Tendinopathy

    PubMed Central

    McCormack, Joshua R.; Underwood, Frank B.; Slaven, Emily J.; Cappaert, Thomas A.

    2016-01-01

    Background: Eccentric exercise is commonly used in the management of Achilles tendinopathy (AT) but its effectiveness for insertional AT has been questioned. Soft tissue treatment (Astym) combined with eccentric exercise could result in better outcomes than eccentric exercise alone. Hypothesis: Soft tissue treatment (Astym) plus eccentric exercise will be more effective than eccentric exercise alone for subjects with insertional AT. Study Design: Prospective randomized controlled trial. Level of Evidence: Level 2. Methods: Sixteen subjects were randomly assigned to either a soft tissue treatment (Astym) and eccentric exercise group or an eccentric exercise–only group. Intervention was completed over a 12-week period, with outcomes assessed at baseline, 4, 8, 12, 26, and 52 weeks. Outcomes included the Victorian Institute of Sport Assessment Achilles-Specific Questionnaire (VISA-A), the numeric pain rating scale (NPRS), and the global rating of change (GROC). Results: Significantly greater improvements on the VISA-A were noted in the soft tissue treatment (Astym) group over the 12-week intervention period, and these differences were maintained at the 26- and 52-week follow-ups. Both groups experienced a similar statistically significant improvement in pain over the short and long term. A significantly greater number of subjects in the soft tissue treatment (Astym) group achieved a successful outcome at 12 weeks. Conclusion: Soft tissue treatment (Astym) plus eccentric exercise was more effective than eccentric exercise only at improving function during both short- and long-term follow-up periods. Clinical Relevance: Soft tissue treatment (Astym) plus eccentric exercise appears to be a beneficial treatment program that clinicians should consider incorporating into the management of their patients with insertional AT. PMID:26893309

  17. Reaction of facial soft tissues to treatment with a Herbst appliance.

    PubMed

    Meyer-Marcotty, P; Kochel, J; Richter, U; Richter, F; Stellzig-Eisenhauer, Angelika

    2012-04-01

    The objective of this prospective longitudinal study was to investigate the reaction of facial soft tissues to treatment with a Herbst appliance. We aimed to quantify three-dimensionally (3D) the isolated effect of the Herbst appliance and volume changes in the lip profile. The 3D data of the facial soft tissues of 34 patients with skeletal Class II (17 female and 17 male, mean age 13.5 ± 1.8 years) were prepared in a standardized manner immediately before (T1) and after (T2) treatment with a Herbst appliance. Anthropometric evaluation was carried out in sagittal and vertical dimensions. To quantify volume changes, pretherapeutic and posttherapeutic images were superimposed three-dimensionally and the difference volumes calculated. Following testing for normal distribution, a statistical analysis was carried out using the paired t test. We observed ventral development of the soft tissues of the lower jaw with flattening of the profile curvature and anterior displacement of the sublabial region in a total of 27 patients. Anterior facial height was lengthened and the facial depth at the lower jaw increased. The largest percentage changes were noted in the lip profile, with a reduction in the red margin of the upper lip and an increase in lower lip height. We also observed a reduction of the sublabial fold in conjunction with a simultaneous increase in volume. The influence of the Herbst appliance on the facial soft tissues is expected to result in a positive treatment outcome, particularly in patients with a convex profile, a retrusive lower lip, and a marked sublabial fold. We observed a broad clinical spectrum of individual reactions in the facial soft tissues. It is, thus, not possible to detect a linear relationship between the Herbst treatment and soft tissue changes, making soft tissue changes difficult to predict.

  18. Incidence of Staphylococcus aureus nasal colonization and soft tissue infection among high school football players.

    PubMed

    Lear, Aaron; McCord, Gary; Peiffer, Jeffrey; Watkins, Richard R; Parikh, Arpan; Warrington, Steven

    2011-01-01

    Methicillin-resistant Staphylococcus aureus (MRSA) skin and soft tissue infections have been documented with increasing frequency in both team and individual sports in recent years. It also seems that the level of MRSA skin and soft tissue infections in the general population has increased. One hundred ninety athletes from 6 local high school football teams were recruited for this prospective observational study to document nasal colonization and the potential role this plays in skin and soft tissue infections in football players and, in particular, MRSA infections. Athletes had nasal swabs done before their season started, and they filled out questionnaires regarding potential risk factors for skin and soft tissue infections. Those enrolled in the study were then observed over the course of the season for skin and soft tissue infections. Those infected had data about their infections collected. One hundred ninety of 386 available student athletes enrolled in the study. Forty-four of the subjects had nasal colonization with methicillin-susceptible S. aureus, and none were colonized with MRSA. There were 10 skin and soft tissue infections (8 bacterial and 2 fungal) documented over the course of the season. All were treated as outpatients with oral or topical antibiotics, and none were considered serious. Survey data from the preseason questionnaire showed 21% with skin infection, 11% with methicillin-susceptible S. aureus, and none with MRSA infection during the past year. Three reported a remote history of MRSA infection. We documented an overall skin infection rate of 5.3% among high school football players over a single season. Our results suggest that skin and soft tissue infection may not be widespread among high school athletes in northeast Ohio.

  19. Soft Tissue Deformations Contribute to the Mechanics of Walking in Obese Adults

    PubMed Central

    Fu, Xiao-Yu; Zelik, Karl E.; Board, Wayne J.; Browning, Raymond C.; Kuo, Arthur D.

    2014-01-01

    Obesity not only adds to the mass that must be carried during walking, but also changes body composition. Although extra mass causes roughly proportional increases in musculoskeletal loading, less well understood is the effect of relatively soft and mechanically compliant adipose tissue. Purpose To estimate the work performed by soft tissue deformations during walking. The soft tissue would be expected to experience damped oscillations, particularly from high force transients following heel strike, and could potentially change the mechanical work demands for walking. Method We analyzed treadmill walking data at 1.25 m/s for 11 obese (BMI > 30 kg/m2) and 9 non-obese (BMI < 30 kg/m2) adults. The soft tissue work was quantified with a method that compares the work performed by lower extremity joints as derived using assumptions of rigid body segments, with that estimated without rigid body assumptions. Results Relative to body mass, obese and non-obese individuals perform similar amounts of mechanical work. But negative work performed by soft tissues was significantly greater in obese individuals (p= 0.0102), equivalent to about 0.36 J/kg vs. 0.27 J/kg in non-obese individuals. The negative (dissipative) work by soft tissues occurred mainly after heel strike, and for obese individuals was comparable in magnitude to the total negative work from all of the joints combined (0.34 J/kg vs. 0.33 J/kg for obese and non-obese adults, respectively). Although the joints performed a relatively similar amount of work overall, obese individuals performed less negative work actively at the knee. Conclusion The greater proportion of soft tissues in obese individuals results in substantial changes in the amount, location, and timing of work, and may also impact metabolic energy expenditure during walking. PMID:25380475

  20. Soft-tissue volumetric changes following monobloc distraction procedure: analysis using digital three-dimensional photogrammetry system (3dMD).

    PubMed

    Chan, Fuan Chiang; Kawamoto, Henry K; Federico, Christina; Bradley, James P

    2013-03-01

    We have previously reported that monobloc advancement by distraction osteogenesis resulted in decreased morbidity and greater advancement with less relapse compared with acute monobloc advancement with bone grafting. In this study, we examine the three-dimensional (3D) volumetric soft-tissue changes in monobloc distraction.Patients with syndromic craniosynostosis who underwent monobloc distraction from 2002 to 2010 at University of California-Los Angeles Craniofacial Center were studied (n = 12). We recorded diagnosis, indications for the surgery, and volumetric changes for skeletal and soft-tissue midface structures (preoperative/postoperative [6 weeks]/follow-up [>1 year]). Computed tomography scans and a digital 3D photogrammetry system were used for image analysis.Patients ranged from 6 to 14 years of age (mean, 10.1 years) at the time of the operation (follow-up 2-11 years); mean distraction advancement was 19.4 mm (range, 14-25 mm). There was a mean increase in the 3D volumetric soft-tissue changes: 99.5 ± 4.0 cm(3) (P < 0.05) at 6 weeks and 94.9 ± 3.6 cm(3) (P < 0.05) at 1-year follow-up. When comparing soft-tissue changes at 6 weeks postoperative to 1-year follow-up, there were minimal relapse changes. The overall mean 3D skeletal change was 108.9 ± 4.2 cm. For every 1 cm of skeletal gain, there was 0.78 cm(3) of soft-tissue gain.Monobloc advancement by distraction osteogenesis using internal devices resulted in increased volumetric soft-tissue changes, which remained stable at 1 year. The positive linear correlation between soft-tissue increments and bony advancement can be incorporated during the planning of osteotomies to achieve optimum surgical outcomes with monobloc distraction.

  1. Soft-Tissue Reconstruction of the Complicated Knee Arthroplasty: Principles and Predictors of Salvage.

    PubMed

    Colen, David L; Carney, Martin J; Shubinets, Valeriy; Lanni, Michael A; Liu, Tiffany; Levin, L Scott; Lee, Gwo-Chin; Kovach, Stephen J

    2018-04-01

    Total knee arthroplasty is a common orthopedic procedure in the United States and complications can be devastating. Soft-tissue compromise or joint infection may cause failure of prosthesis requiring knee fusion or amputation. The role of a plastic surgeon in total knee arthroplasty is critical for cases requiring optimization of the soft-tissue envelope. The purpose of this study was to elucidate factors associated with total knee arthroplasty salvage following complications and clarify principles of reconstruction to optimize outcomes. A retrospective review of patients requiring soft-tissue reconstruction performed by the senior author after total knee arthroplasty over 8 years was completed. Logistic regression and Fisher's exact tests determined factors associated with the primary outcome, prosthesis salvage versus knee fusion or amputation. Seventy-three knees in 71 patients required soft-tissue reconstruction (mean follow-up, 1.8 years), with a salvage rate of 61.1 percent, mostly using medial gastrocnemius flaps. Patients referred to our institution with complicated periprosthetic wounds were significantly more likely to lose their knee prosthesis than patients treated only within our system. Patients with multiple prior knee operations before definitive soft-tissue reconstruction had significantly decreased rates of prosthesis salvage and an increased risk of amputation. Knee salvage significantly decreased with positive joint cultures (Gram-negative greater than Gram-positive organisms) and particularly at the time of definitive reconstruction, which also trended toward an increased risk of amputation. In revision total knee arthroplasty, prompt soft-tissue reconstruction improves the likelihood of success, and protracted surgical courses and contamination increase failure and amputations. The authors show a benefit to involving plastic surgeons early in the course of total knee arthroplasty complications to optimize genicular soft tissues. Therapeutic, III.

  2. Soft tissue volume augmentation at dental implant sites using a volume stable three-dimensional collagen matrix - histological outcomes of a preclinical study.

    PubMed

    Thoma, Daniel S; Naenni, Nadja; Benic, Goran I; Hämmerle, Christoph H F; Jung, Ronald E

    2017-02-01

    The aim of this study was to test whether or not soft tissue augmentation with a collagen matrix (VCMX) leads to a similar increase in ridge width around dental implants compared to the use of an autogenous subepithelial connective tissue graft (SCTG). In 12 dogs, immediate dental implants were placed with simultaneous guided bone regeneration. Three months later, soft tissue volume augmentation was performed by randomly allocating three treatment modalities to these sites [VCMX, SCTG, sham-operated group (control)]. Dogs were sacrificed at 1 (n = 4), 2 (n = 4) or 6 months (n = 4). Descriptive histology and histomorphometric measurements for soft tissue thickness were performed on non-decalcified sections. The horizontal soft tissue thickness was maximal at the most coronal level (alveolar crest) at 1 month (VCMX: 2.1 ± 1.6 mm; SCTG: 2.5 ± 1.7 mm; p = 0.877) and decreased until 6 months. At 6 months, the greatest mucosal thickness was at a level 3.5 mm below the crest (VCMX: 0.8 ± 0.3 mm; SCTG: 0.7 ± 0.2 mm) (p = 0.754). Control sites revealed no relevant soft tissue augmentation at any level and any time-point. Tissue integration for VCMX and SCTG were favourable with minimal inflammatory reactions. Soft tissue volume augmentation at implant sites was obtained to a similar extent using VCMX and SCTG up to 2 months. Thereafter, degradation and remodelling processes were enhanced leading to a minimal increase in soft tissue thickness at 6 months for VCMX and SCTG. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Silk Based Bioinks for Soft Tissue Reconstruction Using 3-Dimensional (3D) Printing with in vitro and in vivo Assessments

    PubMed Central

    Rodriguez, María J.; Brown, Joseph; Giordano, Jodie; Lin, Samuel J.; Omenetto, Fiorenzo G.; Kaplan, David L.

    2016-01-01

    In the field of soft tissue reconstruction, custom implants could address the need for materials that can fill complex geometries. Our aim was to develop a material system with optimal rheology for material extrusion, that can be processed in physiological and non-toxic conditions and provide structural support for soft tissue reconstruction. To meet this need we developed silk based bioinks using gelatin as a bulking agent and glycerol as a non-toxic additive to induce physical crosslinking. We developed these inks optimizing printing efficacy and resolution for patient-specific geometries that can be used for soft tissue reconstruction. We demonstrated in vitro that the material was stable under physiological conditions and could be tuned to match soft tissue mechanical properties. We demonstrated in vivo that the material was biocompatible and could be tuned to maintain shape and volume up to three months while promoting cellular infiltration and tissue integration. PMID:27940389

  4. Silk based bioinks for soft tissue reconstruction using 3-dimensional (3D) printing with in vitro and in vivo assessments.

    PubMed

    Rodriguez, María J; Brown, Joseph; Giordano, Jodie; Lin, Samuel J; Omenetto, Fiorenzo G; Kaplan, David L

    2017-02-01

    In the field of soft tissue reconstruction, custom implants could address the need for materials that can fill complex geometries. Our aim was to develop a material system with optimal rheology for material extrusion, that can be processed in physiological and non-toxic conditions and provide structural support for soft tissue reconstruction. To meet this need we developed silk based bioinks using gelatin as a bulking agent and glycerol as a non-toxic additive to induce physical crosslinking. We developed these inks optimizing printing efficacy and resolution for patient-specific geometries that can be used for soft tissue reconstruction. We demonstrated in vitro that the material was stable under physiological conditions and could be tuned to match soft tissue mechanical properties. We demonstrated in vivo that the material was biocompatible and could be tuned to maintain shape and volume up to three months while promoting cellular infiltration and tissue integration. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Semianalytical Solution for the Deformation of an Elastic Layer under an Axisymmetrically Distributed Power-Form Load: Application to Fluid-Jet-Induced Indentation of Biological Soft Tissues.

    PubMed

    Lu, Minhua; Huang, Shuai; Yang, Xianglong; Yang, Lei; Mao, Rui

    2017-01-01

    Fluid-jet-based indentation is used as a noncontact excitation technique by systems measuring the mechanical properties of soft tissues. However, the application of these devices has been hindered by the lack of theoretical solutions. This study developed a mathematical model for testing the indentation induced by a fluid jet and determined a semianalytical solution. The soft tissue was modeled as an elastic layer bonded to a rigid base. The pressure of the fluid jet impinging on the soft tissue was assumed to have a power-form function. The semianalytical solution was verified in detail using finite-element modeling, with excellent agreement being achieved. The effects of several parameters on the solution behaviors are reported, and a method for applying the solution to determine the mechanical properties of soft tissues is suggested.

  6. Adhesion of Dental Materials to Tooth Structure

    NASA Astrophysics Data System (ADS)

    Mitra, Sumita B.

    2000-03-01

    The understanding and proper application of the principles of adhesion has brought forth a new paradigm in the realm of esthetic dentistry. Modern restorative tooth procedures can now conserve the remaining tooth-structure and also provide for the strengthening of the tooth. Adhesive restorative techniques call for the application and curing of the dental adhesive at the interface between the tooth tissue and the filling material. Hence the success of the restoration depends largely on the integrity of this interface. The mechanism of adhesion of the bonding materials to the dental hard tissue will be discussed in this paper. There are four main steps that occur during the application of the dental adhesive to the oral hard tissues: 1) The first step is the creation of a microstructure in the tooth enamel or dentin by means of an acidic material. This can be through the application of a separate etchant or can be accomplished in situ by the adhesive/primer. This agent has to be effective in removing or modifying the proteinaceous “smear” layer, which would otherwise act as a weak boundary layer on the surface to be bonded. 2) The primer/adhesive must then be able to wet and penetrate the microstructure created in the tooth. Since the surface energies of etched enamel and that of etched dentin are different finding one material to prime both types of dental tissues can be quite challenging. 3) The ionomer types of materials, particularly those that are carboxylate ion-containing, can chemically bond with the calcium ions of the hydroxyapatite mineral. 4) Polymerization in situ allows for micromechanical interlocking of the adhesive. The importance of having the right mechanical properties of the cured adhesive layer and its role in absorbing and dissipating stresses encountered by a restored tooth will also be discussed.

  7. Effects of soft tissue augmentation procedures on peri-implant health or disease: A systematic review and meta-analysis.

    PubMed

    Thoma, Daniel S; Naenni, Nadja; Figuero, Elena; Hämmerle, Christoph H F; Schwarz, Frank; Jung, Ronald E; Sanz-Sánchez, Ignacio

    2018-03-01

    To review the dental literature in terms of soft tissue augmentation procedures and their influence on peri-implant health or disease in partially and fully edentulous patients. A MEDLINE search from 1966 to 2016 was performed to identify controlled clinical studies comparing soft tissue grafting versus no soft tissue grafting (maintenance) or two types of soft tissue grafting procedures at implant sites. The soft tissue grafting procedures included either an increase of keratinized tissue or an increase of the thickness of the peri-implant mucosa. Studies reporting on the peri-implant tissue health, as assessed by bleeding or gingival indices, were included in the review. The search was complemented by an additional hand search of all selected full-text articles and reviews published between 2011 and 2016. The initial search yielded a total number of 2,823 studies. Eligible studies were selected based on the inclusion criteria (finally included: four studies on gain of keratinized tissue; six studies on gain of mucosal thickness) and quality assessments conducted. Meta-analyses were applied whenever possible. Soft tissue grafting procedures for gain of keratinized tissue resulted in a significantly greater improvement of gingival index values compared to maintenance groups (with or without keratinized tissue) [n = 2; WMD = 0.863; 95% CI (0.658; 1.067); p < .001]. For final marginal bone levels, statistically significant differences were calculated in favor of an apically positioned flap (APF) plus autogenous grafts versus all control treatments (APF alone; APF plus a collagen matrix; maintenance without intervention [with or without residual keratinized tissue]) [n = 4; WMD = -0.175 mm; 95% CI: (-0.313; -0.037); p = .013]. Soft tissue grafting procedures for gain of mucosal thickness did not result in significant improvements in bleeding indices over time, but in significantly less marginal bone loss over time [WMD = 0.110; 95% CI: 0.067; 0.154; p < .001] and a borderline significance for marginal bone levels at the study endpoints compared to sites without grafting. Within the limitations of this review, it was concluded that soft tissue grafting procedures result in more favorable peri-implant health: (i) for gain of keratinized mucosa using autogenous grafts with a greater improvement of bleeding indices and higher marginal bone levels; (ii) for gain of mucosal thickness using autogenous grafts with significantly less marginal bone loss. © 2018 The Authors. Clinical Oral Implants Research Published by John Wiley & Sons Ltd.

  8. Guided bone generation in a rabbit mandible model after periosteal expansion with an osmotic tissue expander.

    PubMed

    Abrahamsson, Peter; Isaksson, Sten; Andersson, Gunilla

    2011-11-01

    To evaluate the space-maintaining capacity of titanium mesh covered by a collagen membrane after soft tissue expansion on the lateral border of the mandible in rabbits, and to assess bone quantity and quality using autogenous particulate bone or bone-substitute (Bio-Oss(®) ), and if soft tissue ingrowth can be avoided by covering the mesh with a collagen membrane. In 11 rabbits, a self-inflatable soft tissue expander was placed under the lateral mandibular periosteum via an extra-oral approach. After 2 weeks, the expanders were removed and a particulated onlay bone graft and deproteinized bovine bone mineral (DBBM) (Bio-Oss(®) ) were placed in the expanded area and covered by a titanium mesh. The bone and DBBM were separated in two compartments under the mesh with a collagen membrane in between. The mesh was then covered with a collagen membrane. After 3 months, the animals were sacrificed and specimens were collected for histology. The osmotic soft tissue expander created a subperiosteal pocket and a ridge of new bone formed at the edges of the expanded periosteum in all sites. After the healing period of 3 months, no soft tissue dehiscence was recorded. The mean bone fill was 58.1±18% in the bone grafted area and 56.9±13.7% in the DBBM area. There was no significant difference between the autologous bone graft and the DDBM under the titanium mesh with regard to the total bone area or the mineralized bone area. Scanning electron microscopy showed that new bone was growing in direct contact with the DBBM particles and the titanium mesh. There is a soft tissue ingrowth even after soft tissue expansion and protection of the titanium mesh with a collagen membrane. This study confirms that an osmotic soft tissue expander creates a surplus of periosteum and soft tissue, and that new bone can subsequently be generated under a titanium mesh with the use of an autologous bone graft or DBBM. © 2011 John Wiley & Sons A/S.

  9. Efficacy of tray adhesives for the adhesion of elastomer rubber impression materials to impression modeling plastics for border molding.

    PubMed

    Nishigawa, G; Sato, T; Suenaga, K; Minagi, S

    1998-02-01

    Tray adhesive, which is used for the adhesion of elastomer rubber impression materials to a custom resin tray, lowers the retention of the impression materials to the impression modeling plastics, as some ingredients of tray adhesive make the impression modeling plastic soft and tacky. The efficacy of tray adhesive, which is used for the adhesion of elastomer rubber impression materials to a custom resin tray, on the adhesion between elastomer rubber impression material and impression modeling plastic was investigated. Four silicone rubber impression materials (two addition reaction types and two condensation reaction types), two polysulfide rubber impression materials, and one impression modeling plastic were used in this study. Tensile strength between elastomer rubber impression material and impression modeling plastic with or without the application of tray adhesive was evaluated. Although tray adhesives for both addition reaction type and both condensation reaction type of silicone impression materials and one tray adhesive for polysulfide rubber impression material increased the tensile strength between the impression material and impression modeling plastic, one tray adhesive for polysulfide rubber impression material decreased the tensile strength when sufficient drying time was not applied.

  10. Comparative evaluation of absorbable hemostats: advantages of fibrin-based sheets.

    PubMed

    Krishnan, Lissy K; Mohanty, Mira; Umashankar, P R; Lal, Arthur Vijayan

    2004-11-01

    Bioactive hemostats and wound dressings consist of either inherently active materials or act as delivery vehicles which contain such materials. Fibrin is a natural hemostat and scaffold, guiding the direction of wound contraction and closure. In order to improve the ease of application of liquid fibrin glue, we have made a freeze-dried form of polymerized fibrin that supports hemostasis and wound healing. The bleeding from the middle ear artery of rabbits was found to be arrested instantaneously on application of fibrin sheets, even when the animal was heparinized systemically. As the fibrin sheet was found to be fragile, gelatin was incorporated to the sheet and thus the mechanical stability was improved without compromising the hemostatic effect. The efficacy of the fabricated fibrin and fibrin-gelatin sheets to seal traumatized rat liver was compared with commercially available hemostats, Abgel (cross-linked gelatin) and Surgicel (cross-linked cellulose). Tissue compatibility of all the hemostats was studied by analyzing the liver tissue 15 days after application. While the hemostatic effect was best with fibrin and fibrin-gelatin sheets, both Surgicel and Abgel were not capable of arresting the bleeding quickly. Gross analysis of tissue on the 15th day of application, visibly, Abgel was not only degraded but resulted in severe adhesions of internal organs and histologically capsule formation around the implant was evident. Though Surgicel was also seen as cream soft material on the site of application that joined two pieces of liver, there was no adhesion of other internal organs and histologically, immune reaction and foreign-body-type giant cells were present in large amounts. Fibrin was not found grossly on application site whereas fibrin-gelatin was seen as a small white spot. Granulation tissue formation and cell migration into the fibrin-based sheets were evident, and therefore, fibrin-based sheets are not only efficient hemostats but showed optimum degradation and wound healing.

  11. Adhesive protein interactions with chitosan: consequences for valve endothelial cell growth on tissue-engineering materials.

    PubMed

    Cuy, Janet L; Beckstead, Benjamin L; Brown, Chad D; Hoffman, Allan S; Giachelli, Cecilia M

    2003-11-01

    Stable endothelialization of a tissue-engineered heart valve is essential for proper valve function, although adhesive characteristics of the native valve endothelial cell (VEC) have rarely been explored. This research evaluated VEC adhesive qualities and attempted to enhance VEC growth on the biopolymer chitosan, a novel tissue-engineering scaffold material with promising biological and chemical properties. Aortic VEC cultures were isolated and found to preferentially adhere to fibronectin, collagen types IV and I over laminin and osteopontin in a dose-dependent manner. Seeding of VEC onto comparison substrates revealed VEC growth and morphology to be preferential in the order: tissue culture polystyrene > gelatin, poly(DL-lactide-co-glycolide), chitosan > poly(hydroxy alkanoate). Adhesive protein precoating of chitosan did not significantly enhance VEC growth, despite equivalent protein adsorption as to polystyrene. Initial cell adhesion to protein-precoated chitosan, however, was higher than for polystyrene. Composite chitosan/collagen type IV films were investigated as an alternative to simple protein precoatings, and were shown to improve VEC growth and morphology over chitosan alone. These findings suggest potential manipulation of chitosan properties to improve amenability to valve tissue-engineering applications. Copyright 2003 Wiley Periodicals, Inc.

  12. Surgical hazards posed by marine and freshwater animals in Florida.

    PubMed

    Howard, R J; Burgess, G H

    1993-11-01

    Marine and freshwater animals can cause injury to humans by biting, stinging, being poisonous to eat, and causing infections. Biting aquatic animals in Florida include sharks, barracudas, alligators, and moray eels. Devitalized tissue should be débrided, and vascular, neurologic, and tendinous injuries should be repaired. Radiographs should be obtained to examine the injury sit for fractures and retained foreign bodies (teeth). The spines of stingrays and marine catfish can cause soft tissue injury and infection. The spine has a recurved, serrated shape that may cause further injury and break if it is pulled out. The venom may cause local tissue necrosis requiring débridement. Soft tissue infections with marine Vibrio bacteria can occur after eating raw oysters or receiving even minor injuries from marine animals. Thirty-one individuals developed soft tissue infections, 49 developed sepsis, and 23 developed both sepsis and soft tissue infection with marine Vibrio species during a 12-year period. Sixteen patients developed necrotizing soft tissue infections. Treatment is with antibiotics and débridement when necrosis occurs.

  13. Nucleation theory with delayed interactions: An application to the early stages of the receptor-mediated adhesion/fusion kinetics of lipid vesicles

    NASA Astrophysics Data System (ADS)

    Raudino, Antonio; Pannuzzo, Martina

    2010-01-01

    A semiquantitative theory aimed to describe the adhesion kinetics between soft objects, such as living cells or vesicles, has been developed. When rigid bodies are considered, the adhesion kinetics is successfully described by the classical Derjaguin, Landau, Verwey, and Overbeek (DLVO) picture, where the energy profile of two approaching bodies is given by a two asymmetrical potential wells separated by a barrier. The transition probability from the long-distance to the short-distance minimum defines the adhesion rate. Conversely, soft bodies might follow a different pathway to reach the short-distance minimum: thermally excited fluctuations give rise to local protrusions connecting the approaching bodies. These transient adhesion sites are stabilized by short-range adhesion forces (e.g., ligand-receptor interactions between membranes brought at contact distance), while they are destabilized both by repulsive forces and by the elastic deformation energy. Above a critical area of the contact site, the adhesion forces prevail: the contact site grows in size until the complete adhesion of the two bodies inside a short-distance minimum is attained. This nucleation mechanism has been developed in the framework of a nonequilibrium Fokker-Planck picture by considering both the adhesive patch growth and dissolution processes. In addition, we also investigated the effect of the ligand-receptor pairing kinetics at the adhesion site in the time course of the patch expansion. The ratio between the ligand-receptor pairing kinetics and the expansion rate of the adhesion site is of paramount relevance in determining the overall nucleation rate. The theory enables one to self-consistently include both thermodynamics (energy barrier height) and dynamic (viscosity) parameters, giving rise in some limiting cases to simple analytical formulas. The model could be employed to rationalize fusion kinetics between vesicles, provided the short-range adhesion transition is the rate-limiting step to the whole adhesion process. Approximate relationships between the experimental fusion rates reported in the literature and parameters such as membrane elastic bending modulus, repulsion strength, temperature, osmotic forces, ligand-receptor binding energy, solvent and membrane viscosities are satisfactory explained by our model. The present results hint a possible role of the initial long-distance→short-distance transition in determining the whole fusion kinetics.

  14. Nucleation theory with delayed interactions: an application to the early stages of the receptor-mediated adhesion/fusion kinetics of lipid vesicles.

    PubMed

    Raudino, Antonio; Pannuzzo, Martina

    2010-01-28

    A semiquantitative theory aimed to describe the adhesion kinetics between soft objects, such as living cells or vesicles, has been developed. When rigid bodies are considered, the adhesion kinetics is successfully described by the classical Derjaguin, Landau, Verwey, and Overbeek (DLVO) picture, where the energy profile of two approaching bodies is given by a two asymmetrical potential wells separated by a barrier. The transition probability from the long-distance to the short-distance minimum defines the adhesion rate. Conversely, soft bodies might follow a different pathway to reach the short-distance minimum: thermally excited fluctuations give rise to local protrusions connecting the approaching bodies. These transient adhesion sites are stabilized by short-range adhesion forces (e.g., ligand-receptor interactions between membranes brought at contact distance), while they are destabilized both by repulsive forces and by the elastic deformation energy. Above a critical area of the contact site, the adhesion forces prevail: the contact site grows in size until the complete adhesion of the two bodies inside a short-distance minimum is attained. This nucleation mechanism has been developed in the framework of a nonequilibrium Fokker-Planck picture by considering both the adhesive patch growth and dissolution processes. In addition, we also investigated the effect of the ligand-receptor pairing kinetics at the adhesion site in the time course of the patch expansion. The ratio between the ligand-receptor pairing kinetics and the expansion rate of the adhesion site is of paramount relevance in determining the overall nucleation rate. The theory enables one to self-consistently include both thermodynamics (energy barrier height) and dynamic (viscosity) parameters, giving rise in some limiting cases to simple analytical formulas. The model could be employed to rationalize fusion kinetics between vesicles, provided the short-range adhesion transition is the rate-limiting step to the whole adhesion process. Approximate relationships between the experimental fusion rates reported in the literature and parameters such as membrane elastic bending modulus, repulsion strength, temperature, osmotic forces, ligand-receptor binding energy, solvent and membrane viscosities are satisfactory explained by our model. The present results hint a possible role of the initial long-distance-->short-distance transition in determining the whole fusion kinetics.

  15. Mussel-inspired hyperbranched poly(amino ester) polymer as strong wet tissue adhesive.

    PubMed

    Zhang, Hong; Bré, Lígia P; Zhao, Tianyu; Zheng, Yu; Newland, Ben; Wang, Wenxin

    2014-01-01

    Current medical adhesives based on cyanoacrylates typically exhibit cellular toxicity. In contrast, fibrin adhesives are non-toxic but have poor adhesive properties. To overcome these drawbacks we designed a simple and scalable adhesive precursor inspired by marine mussel adhesion that functioned with strong adhesion in wet conditions and with low cytotoxicity. Dopamine, an-amine derivative of an amino acid abundantly present in mussel adhesive proteins, was co-polymerised with a tri-functional vinyl monomer, to form a hyperbranched poly(β-amino ester) polymer termed poly(dopamine-co-acrylate) (PDA). A variety of molecular weights and crosslinking methods were analysed using an ex vivo porcine skin model and an almost 4 fold increase in wet adhesion strength was observed compared to TISSEEL(®) fibrin sealant. With a fast curing time, degradable properties and low cytotoxicity, PDA is highly attractive for medical purposes and could have a broad impact on surgeries where surgical tissue adhesives, sealants, and haemostatic agents are used. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Soft Tissue Regeneration Incorporating 3-Dimensional Biomimetic Scaffolds.

    PubMed

    Shah, Gaurav; Costello, Bernard J

    2017-02-01

    Soft tissue replacement and repair is crucial to the ever-developing field of reconstructive surgery as trauma, pathology, and congenital deficits cannot be adequately restored if soft tissue regeneration is deficient. Predominant approaches were sometimes limited to harvesting autografts, but through regenerative medicine and tissue engineering, the hope of fabricating custom constructs is now a feasible and fast-approaching reality. The breadth of this field includes tissues ranging from skin, mucosa, muscle, and fat and hopes to not only provide construct to replace a tissue but also to replace its function. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Randomized controlled clinical study evaluating effectiveness and safety of a volume-stable collagen matrix compared to autogenous connective tissue grafts for soft tissue augmentation at implant sites.

    PubMed

    Thoma, Daniel S; Zeltner, Marco; Hilbe, Monika; Hämmerle, Christoph H F; Hüsler, Jürg; Jung, Ronald E

    2016-10-01

    To test whether or not the use of a collagen matrix (VCMX) results in short-term soft tissue volume increase at implant sites non-inferior to an autogenous subepithelial connective tissue graft (SCTG), and to evaluate safety and tissue integration of VCMX and SCTG. In 20 patients with a volume deficiency at single-tooth implant sites, soft tissue volume augmentation was performed randomly allocating VCMX or SCTG. Soft tissue thickness, patient-reported outcome measures (PROMs), and safety were assessed up to 90 days (FU-90). At FU-90 (abutment connection), tissue samples were obtained for histological analysis. Descriptive analysis was computed for both groups. Non-parametric tests were applied to test non-inferiority for the gain in soft tissue thickness at the occlusal site. Median soft tissue thickness increased between BL and FU-90 by 1.8 mm (Q1:0.5; Q3:2.0) (VCMX) (p = 0.018) and 0.5 mm (-1.0; 2.0) (SCTG) (p = 0.395) (occlusal) and by 1.0 mm (0.5; 2.0) (VCMX) (p = 0.074) and 1.5 mm (-2.0; 2.0) (SCTG) (p = 0.563) (buccal). Non-inferiority with a non-inferiority margin of 1 mm could be demonstrated (p = 0.020); the difference between the two group medians (1.3 mm) for occlusal sites indicated no relevant, but not significant superiority of VCMX versus SCTG (primary endpoint). Pain medication consumption and pain perceived were non-significantly higher in group SCTG up to day 3. Median physical pain (OHIP-14) at day 7 was 100% higher for SCTG than for VCMX. The histological analysis revealed well-integrated grafts. Soft tissue augmentation at implant sites resulted in a similar or higher soft tissue volume increase after 90 days for VCMX versus SCTG. PROMs did not reveal relevant differences between the two groups. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Soft tissue hemangioma with osseous extension: a case report and review of the literature.

    PubMed

    Daoud, Alexander; Olivieri, Brandon; Feinberg, Daniel; Betancourt, Michel; Bockelman, Brian

    2015-04-01

    Soft tissue hemangiomas are commonly encountered lesions, accounting for 7-10 % of all benign soft tissue masses (Mitsionis et al. J Foot Ankle Surg 16(2):27-9, 2010). While the literature describes the great majority of hemangiomas as asymptomatic and discovered only as incidental findings, they do have the potential to induce reactive changes in neighboring structures (Pastushyn et al. Surg Neurol 50(6):535-47, 1998). When these variants occur in close proximity to bone, they may elicit a number of well-documented reactive changes in osseous tissue (Mitsionis et al. J Foot Ankle Surg 16(2):27-9, 2010; DeFilippo et al. Skelet Radiol 25(2):174-7, 1996; Ly et al. AJR Am J Roentgenol 180(6):1695-700, 2003; Sung et al. Skelet Radiol 27(4):205-10, 1998). However, instances of direct extension into bone by soft tissue hemangiomas--that is, infiltration of the mass's vascular components into nearby osseous tissue--are currently undocumented in the literature. In these cases, imaging plays an important role in differentiating hemangiomas from malignant lesions (Mitsionis et al. J Foot Ankle Surg 16(2):27-9, 2010; Sung et al. Skelet Radiol 27(4):205-10, 1998; Pourbagher, Br J Radiol 84(1008):1100-8, 2011). In this article, we present such a case that involved the sacral spine. Imaging revealed a soft tissue mass with direct extension of vascular components into osseous tissue of the adjacent sacral vertebrae. Biopsy and subsequent histopathologic examination led to definitive diagnosis of soft tissue hemangioma. While MRI is widely regarded as the gold standard imaging modality for evaluating hemangiomas, in this report we describe how CT can aid in narrowing the differential diagnosis when one encounters a vascular lesion with adjacent osseous changes. Furthermore, we review the literature as it pertains to the imaging of soft tissue hemangiomas that occur in proximity to osseous tissue, as well as correlate this case to current theories on the pathogenesis of hemangiomas. Radiologists should be aware that benign soft tissue hemangiomas demonstrate a spectrum of imaging findings, including aggressive-appearing changes to adjacent bone.

  19. Fatigue Damage of Collagenous Tissues: Experiment, Modeling and Simulation Studies

    PubMed Central

    Martin, Caitlin; Sun, Wei

    2017-01-01

    Mechanical fatigue damage is a critical issue for soft tissues and tissue-derived materials, particularly for musculoskeletal and cardiovascular applications; yet, our understanding of the fatigue damage process is incomplete. Soft tissue fatigue experiments are often difficult and time-consuming to perform, which has hindered progress in this area. However, the recent development of soft-tissue fatigue-damage constitutive models has enabled simulation-based fatigue analyses of tissues under various conditions. Computational simulations facilitate highly controlled and quantitative analyses to study the distinct effects of various loading conditions and design features on tissue durability; thus, they are advantageous over complex fatigue experiments. Although significant work to calibrate the constitutive models from fatigue experiments and to validate predictability remains, further development in these areas will add to our knowledge of soft-tissue fatigue damage and will facilitate the design of durable treatments and devices. In this review, the experimental, modeling, and simulation efforts to study collagenous tissue fatigue damage are summarized and critically assessed. PMID:25955007

  20. Next Generation Tissue Engineering of Orthopedic Soft Tissue-to-Bone Interfaces.

    PubMed

    Boys, Alexander J; McCorry, Mary Clare; Rodeo, Scott; Bonassar, Lawrence J; Estroff, Lara A

    2017-09-01

    Soft tissue-to-bone interfaces are complex structures that consist of gradients of extracellular matrix materials, cell phenotypes, and biochemical signals. These interfaces, called entheses for ligaments, tendons, and the meniscus, are crucial to joint function, transferring mechanical loads and stabilizing orthopedic joints. When injuries occur to connected soft tissue, the enthesis must be re-established to restore function, but due to structural complexity, repair has proven challenging. Tissue engineering offers a promising solution for regenerating these tissues. This prospective review discusses methodologies for tissue engineering the enthesis, outlined in three key design inputs: materials processing methods, cellular contributions, and biochemical factors.

  1. Next Generation Tissue Engineering of Orthopedic Soft Tissue-to-Bone Interfaces

    PubMed Central

    Boys, Alexander J.; McCorry, Mary Clare; Rodeo, Scott; Bonassar, Lawrence J.; Estroff, Lara A.

    2017-01-01

    Soft tissue-to-bone interfaces are complex structures that consist of gradients of extracellular matrix materials, cell phenotypes, and biochemical signals. These interfaces, called entheses for ligaments, tendons, and the meniscus, are crucial to joint function, transferring mechanical loads and stabilizing orthopedic joints. When injuries occur to connected soft tissue, the enthesis must be re-established to restore function, but due to structural complexity, repair has proven challenging. Tissue engineering offers a promising solution for regenerating these tissues. This prospective review discusses methodologies for tissue engineering the enthesis, outlined in three key design inputs: materials processing methods, cellular contributions, and biochemical factors. PMID:29333332

  2. Tissue Anisotropy Modeling Using Soft Composite Materials.

    PubMed

    Chanda, Arnab; Callaway, Christian

    2018-01-01

    Soft tissues in general exhibit anisotropic mechanical behavior, which varies in three dimensions based on the location of the tissue in the body. In the past, there have been few attempts to numerically model tissue anisotropy using composite-based formulations (involving fibers embedded within a matrix material). However, so far, tissue anisotropy has not been modeled experimentally. In the current work, novel elastomer-based soft composite materials were developed in the form of experimental test coupons, to model the macroscopic anisotropy in tissue mechanical properties. A soft elastomer matrix was fabricated, and fibers made of a stiffer elastomer material were embedded within the matrix material to generate the test coupons. The coupons were tested on a mechanical testing machine, and the resulting stress-versus-stretch responses were studied. The fiber volume fraction (FVF), fiber spacing, and orientations were varied to estimate the changes in the mechanical responses. The mechanical behavior of the soft composites was characterized using hyperelastic material models such as Mooney-Rivlin's, Humphrey's, and Veronda-Westmann's model and also compared with the anisotropic mechanical behavior of the human skin, pelvic tissues, and brain tissues. This work lays the foundation for the experimental modelling of tissue anisotropy, which combined with microscopic studies on tissues can lead to refinements in the simulation of localized fiber distribution and orientations, and enable the development of biofidelic anisotropic tissue phantom materials for various tissue engineering and testing applications.

  3. Tissue Anisotropy Modeling Using Soft Composite Materials

    PubMed Central

    Callaway, Christian

    2018-01-01

    Soft tissues in general exhibit anisotropic mechanical behavior, which varies in three dimensions based on the location of the tissue in the body. In the past, there have been few attempts to numerically model tissue anisotropy using composite-based formulations (involving fibers embedded within a matrix material). However, so far, tissue anisotropy has not been modeled experimentally. In the current work, novel elastomer-based soft composite materials were developed in the form of experimental test coupons, to model the macroscopic anisotropy in tissue mechanical properties. A soft elastomer matrix was fabricated, and fibers made of a stiffer elastomer material were embedded within the matrix material to generate the test coupons. The coupons were tested on a mechanical testing machine, and the resulting stress-versus-stretch responses were studied. The fiber volume fraction (FVF), fiber spacing, and orientations were varied to estimate the changes in the mechanical responses. The mechanical behavior of the soft composites was characterized using hyperelastic material models such as Mooney-Rivlin's, Humphrey's, and Veronda-Westmann's model and also compared with the anisotropic mechanical behavior of the human skin, pelvic tissues, and brain tissues. This work lays the foundation for the experimental modelling of tissue anisotropy, which combined with microscopic studies on tissues can lead to refinements in the simulation of localized fiber distribution and orientations, and enable the development of biofidelic anisotropic tissue phantom materials for various tissue engineering and testing applications. PMID:29853996

  4. Local application of periodontal ligament stromal cells promotes soft tissue regeneration.

    PubMed

    Baik, H S; Park, J; Lee, K J; Chung, C

    2014-09-01

    To test the potential stimulatory effect of local application of periodontal ligament (PDL) stromal cells on soft tissue regeneration. Fluorescently labeled PDL cells outgrown from extracted human premolars or phosphate-buffered saline were locally injected to the cutaneous wounds created on mice. Soft tissue regeneration was evaluated for 14 days using photographs and histomorphometry. PDL cell engraftment was tracked with confocal microscopy. To detect the paracrine effect of the PDL cells on soft tissue regeneration, PDL cell-conditioned medium (CM) was evaluated for the concentration of secretory factors, transforming growth factor-beta 1 (TGFβ1). The effect of PDL CM on the proliferation and migration of dermal fibroblast and keratinocyte was tested using MTT assay and migration assay. The application of PDL cells significantly promoted soft tissue regeneration compared with the application of PBS. Self-replicating PDL cells were engrafted into the hair follicles of the host tissue. Dermal fibroblast proliferation and keratinocyte migration were significantly enhanced by the treatment with PDL CM. Physiologically significant amount of TGFβ1 was secreted from PDL cells into the CM. Local injection of PDL cells promoted soft tissue regeneration in part by the enhancement of fibroblast proliferation and keratinocyte migration through a paracrine mechanism. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. New Soft Tissue Implants Using Organic Elastomers

    NASA Astrophysics Data System (ADS)

    Ku, David N.

    Typical biomaterials are stiff, difficult to manufacture, and not initially developed for medical implants. A new biomaterial is proposed that is similar to human soft tissue. The biomaterial provides mechanical properties similar to soft tissue in its mechanical and physical properties. Characterization is performed for modulus of elasticity, ultimate strength and wear resistance. The material further exhibits excellent biocompatibility with little toxicity and low inflammation. The material can be molded into a variety of anatomic shapes for use as a cartilage replacement, heart valve, and reconstructive implant for trauma victims. The biomaterial may be suitable for several biodevices of the future aimed at soft-tissue replacements.

  6. Palaeoneurological clues to the evolution of defining mammalian soft tissue traits

    PubMed Central

    Benoit, J.; Manger, P. R.; Rubidge, B. S.

    2016-01-01

    A rich fossil record chronicles the distant origins of mammals, but the evolution of defining soft tissue characters of extant mammals, such as mammary glands and hairs is difficult to interpret because soft tissue does not readily fossilize. As many soft tissue features are derived from dermic structures, their evolution is linked to that of the nervous syutem, and palaeoneurology offers opportunities to find bony correlates of these soft tissue features. Here, a CT scan study of 29 fossil skulls shows that non-mammaliaform Prozostrodontia display a retracted, fully ossified, and non-ramified infraorbital canal for the infraorbital nerve, unlike more basal therapsids. The presence of a true infraorbital canal in Prozostrodontia suggests that a motile rhinarium and maxillary vibrissae were present. Also the complete ossification of the parietal fontanelle (resulting in the loss of the parietal foramen) and the development of the cerebellum in Probainognathia may be pleiotropically linked to the appearance of mammary glands and having body hair coverage since these traits are all controlled by the same homeogene, Msx2, in mice. These suggest that defining soft tissue characters of mammals were already present in their forerunners some 240 to 246 mya. PMID:27157809

  7. Soft tissue gas gangrene: a severe complication of emphysematous cholecystitis.

    PubMed

    Safioleas, Michael; Stamatakos, Michael; Kanakis, Meletios; Sargedi, Constantina; Safioleas, Constantinos; Smirnis, Anastasios; Vaiopoulos, George

    2007-12-01

    Soft tissue gas gangrene with myonecrosis is a severe complication of traumatic and non-traumatic conditions with a potentially lethal outcome. Emphysematous cholecystitis is a complication of acute cholecystitis, which is characterized by air accumulation in the gallbladder wall and is reported in the literature as a rare causative factor of soft tissue gas gangrene. Here we report 4 patients who developed soft tissue gas gangrene as a complication of emphysematous cholecystitis. Two patients were female octogenarians (one with a history of diabetes mellitus), and underwent percutaneous trans-gallbladder drainage and fascia incisions of the affected soft tissue with prompt administration of antibiotics. Finally, both of them died. The other two patients were male (32 years old diabetic and 47 years old with a history of chronic alcoholism). They underwent open cholecystectomy. Fascia incisions of the gangrenous areas and antibiotic therapy administration were also performed. Both of them were discharged from the hospital and are currently in excellent clinical status. We also present the ultrasonographic and/or radiologic images of these four patients. Soft tissue gas gangrene may complicate emphysematous cholecystitis, and clinicians should be aware of the coexistence of these two clinical conditions, since immediate management is needed in order to prevent fatal outcome.

  8. Paraspinal Transposition Flap for Reconstruction of Sacral Soft Tissue Defects: A Series of 53 Cases from a Single Institute

    PubMed Central

    Chattopadhyay, Debarati; Agarwal, Akhilesh Kumar; Guha, Goutam; Bhattacharya, Nirjhar; Chumbale, Pawan K; Gupta, Souradip; Murmu, Marang Buru

    2014-01-01

    Study Design Case series. Purpose To describe paraspinal transposition flap for coverage of sacral soft tissue defects. Overview of Literature Soft tissue defects in the sacral region pose a major challenge to the reconstructive surgeon. Goals of sacral wound reconstruction are to provide a durable skin and soft tissue cover adequate for even large sacral defects; minimize recurrence; and minimize donor site morbidity. Various musculocutaneous and fasciocutanous flaps have been described in the literature. Methods The flap was applied in 53 patients with sacral soft tissue defects of diverse etiology. Defects ranged in size from small (6 cm×5 cm) to extensive (21 cm×10 cm). The median age of the patients was 58 years (range, 16-78 years). Results There was no flap necrosis. Primary closure of donor sites was possible in all the cases. The median follow up of the patients was 33 months (range, 4-84 months). The aesthetic outcomes were acceptable. There has been no recurrence of pressure sores. Conclusions The authors conclude that paraspinal transposition flap is suitable for reconstruction of large sacral soft tissue defects with minimum morbidity and excellent long term results. PMID:24967044

  9. Deformation of Soft Tissue and Force Feedback Using the Smoothed Particle Hydrodynamics

    PubMed Central

    Liu, Xuemei; Wang, Ruiyi; Li, Yunhua; Song, Dongdong

    2015-01-01

    We study the deformation and haptic feedback of soft tissue in virtual surgery based on a liver model by using a force feedback device named PHANTOM OMNI developed by SensAble Company in USA. Although a significant amount of research efforts have been dedicated to simulating the behaviors of soft tissue and implementing force feedback, it is still a challenging problem. This paper introduces a kind of meshfree method for deformation simulation of soft tissue and force computation based on viscoelastic mechanical model and smoothed particle hydrodynamics (SPH). Firstly, viscoelastic model can present the mechanical characteristics of soft tissue which greatly promotes the realism. Secondly, SPH has features of meshless technique and self-adaption, which supply higher precision than methods based on meshes for force feedback computation. Finally, a SPH method based on dynamic interaction area is proposed to improve the real time performance of simulation. The results reveal that SPH methodology is suitable for simulating soft tissue deformation and force feedback calculation, and SPH based on dynamic local interaction area has a higher computational efficiency significantly compared with usual SPH. Our algorithm has a bright prospect in the area of virtual surgery. PMID:26417380

  10. Decellularized skin/adipose tissue flap matrix for engineering vascularized composite soft tissue flaps.

    PubMed

    Zhang, Qixu; Johnson, Joshua A; Dunne, Lina W; Chen, Youbai; Iyyanki, Tejaswi; Wu, Yewen; Chang, Edward I; Branch-Brooks, Cynthia D; Robb, Geoffrey L; Butler, Charles E

    2016-04-15

    Using a perfusion decellularization protocol, we developed a decellularized skin/adipose tissue flap (DSAF) comprising extracellular matrix (ECM) and intact vasculature. Our DSAF had a dominant vascular pedicle, microcirculatory vascularity, and a sensory nerve network and retained three-dimensional (3D) nanofibrous structures well. DSAF, which was composed of collagen and laminin with well-preserved growth factors (e.g., vascular endothelial growth factor, basic fibroblast growth factor), was successfully repopulated with human adipose-derived stem cells (hASCs) and human umbilical vein endothelial cells (HUVECs), which integrated with DSAF and formed 3D aggregates and vessel-like structures in vitro. We used microsurgery techniques to re-anastomose the recellularized DSAF into nude rats. In vivo, the engineered flap construct underwent neovascularization and constructive remodeling, which was characterized by the predominant infiltration of M2 macrophages and significant adipose tissue formation at 3months postoperatively. Our results indicate that DSAF co-cultured with hASCs and HUVECs is a promising platform for vascularized soft tissue flap engineering. This platform is not limited by the flap size, as the entire construct can be immediately perfused by the recellularized vascular network following simple re-integration into the host using conventional microsurgical techniques. Significant soft tissue loss resulting from traumatic injury or tumor resection often requires surgical reconstruction using autologous soft tissue flaps. However, the limited availability of qualitative autologous flaps as well as the donor site morbidity significantly limits this approach. Engineered soft tissue flap grafts may offer a clinically relevant alternative to the autologous flap tissue. In this study, we engineered vascularized soft tissue free flap by using skin/adipose flap extracellular matrix scaffold (DSAF) in combination with multiple types of human cells. Following vascular reanastomosis in the recipient site, the engineered products successful regenerated large-scale fat tissue in vivo. This approach may provide a translatable platform for composite soft tissue free flap engineering for microsurgical reconstruction. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  11. Soft tissue sealing around dental implants based on histological interpretation.

    PubMed

    Atsuta, Ikiru; Ayukawa, Yasunori; Kondo, Ryosuke; Oshiro, Wakana; Matsuura, Yuri; Furuhashi, Akihiro; Tsukiyama, Yoshihiro; Koyano, Kiyoshi

    2016-01-01

    The aim of this study was to provide an overview on the biology and soft tissue sealing around dental implants and teeth. This is a narrative review performed through scientific articles published between 1977 and 2014, indexed in MEDLINE and PubMed databases. The study selected articles that focused on epithelial sealing around dental implant or teeth with cell biology and histology of soft tissue. Implant therapy has been widely applied in dental rehabilitation for many years, with predictable long-term results. The longevity and functionality of dental implants is dependent on both osseointegration around the implant body and the establishment of a soft tissue barrier that protects the underlying hard tissue structures and the implant itself. The health and stability of the peri-implant mucosa also affects the esthetics of the implant. The healing and maintenance of the epithelial and connective tissues around implants are increasingly recognized as being fundamental to implant success. However, there has been little research into the function or formation of the soft tissue seal around dental implants, and the roles of this unique mucosal interface remain unclear. This narrative review explores the extent of the current knowledge of soft tissue barriers around implants from both a basic and clinical perspective, and aims to consolidate this knowledge and highlight the most pertinent questions relating to this area of research. Copyright © 2015 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  12. Harvesting keratolimbal allografts from corneoscleral buttons: a novel application of cyanoacrylate adhesive.

    PubMed

    Lim, L T; Bhatt, P R; Ramaesh, K

    2008-11-01

    To describe an alternative and novel technique using cyanoacrylate glue to achieve successful limbal tissue dissection, from an organ culture media stored corneoscleral button, without an artificial anterior chamber. A donor corneoscleral button (leftover from penetrating keratoplasty) was divided into two equal semicircular halves. A thick layer of tissue adhesive (N-butyl-2-cyanoacrylate) was spread on a sterile rubber block (the under surface of the donor punch). One half of the donor corneoscleral rim was placed epithelial side up on the adhesive and allowed to attach firmly to the block. This composite provided stability to the donor rim allowing lamellar dissection of the limbal tissue to be performed without damaging the limbal epithelium. Regular, partial-thickness limbal tissue was obtained. There was no histological evidence of glue or cellular toxicity of the harvested limbal stem cells. This harvested tissue had been grafted successfully in patients with limbal stem cell deficiency also undergoing keratoplasty. Tissue adhesive can be a simple, effective and useful tool in the dissection and harvesting of corneal limbal stem cell allografts from corneoscleral buttons stored in organ culture media.

  13. Nonthrombogenic Hydrogel Coatings with Carbene-Cross-Linking Bioadhesives.

    PubMed

    Nanda, Himansu Sekhar; Shah, Ankur Harish; Wicaksono, Gautama; Pokholenko, Oleksandr; Gao, Feng; Djordjevic, Ivan; Steele, Terry W J

    2018-05-14

    Bioadhesives are a current unmet clinical need for mending of blood contacting soft tissues without inducing thrombosis. Recent development of carbene precursor bioadhesives with the advantages of on-demand curing, tuneable modulus, and wet adhesion have been synthesized by grafting diazirine onto poly (amidoamine) (PAMAM-G5) dendrimers. Herein, the structure activity relationships of platelet adhesion and activation is evaluated for the first time on the cured PAMAM-g-diazirine bioadhesives. Three strategies were employed to prevent healthy human donor platelets from adhering and activating on light-cured bioadhesive surfaces: (1) Attenuation of cationic surface charge, (2) antifouling composites by incorporating heparin and alginate in uncured formulation, and (3) heparin wash of cured bioadhesive surface. Topographical imaging of cured and ethanol dehydrated bioadhesive surfaces was used to quantify the adhered and activated platelets with scanning electron microscopy, whose resolution allowed identification of round senescent, short dendritic, and long dendritic platelets. Cured surfaces of PAMAM-g-diazirine (15%) had 10300 ± 500 adhered platelets mm -2 with 99.7% activation into short/long dendritic cells. Reduction of primary amines by higher degree of diazirine grafting or capping of free amines by acetylation reduces platelet adherence (2400 ± 200 vs 3000 ± 300, respectively). Physical incorporation of heparin and alginate in the formulations reduced the activated platelet; 1300 ± 300 and 300 ± 50, activated platelets mm -2 , in comparison with additive free adhesive formulation. Similarly, heparin rinse of the surface of additive free bioadhesive reduced the activated platelet to platelets of heparin composites at 600 ± 100 platelets mm -2 . PAMAM-g-diazirine (15%) bioadhesive retained the photocured mechanical properties and lap shear adhesion despite the addition of heparin and alginate additives.

  14. Hydrogenated amorphous silicon coatings may modulate gingival cell response

    NASA Astrophysics Data System (ADS)

    Mussano, F.; Genova, T.; Laurenti, M.; Munaron, L.; Pirri, C. F.; Rivolo, P.; Carossa, S.; Mandracci, P.

    2018-04-01

    Silicon-based materials present a high potential for dental implant applications, since silicon has been proven necessary for the correct bone formation in animals and humans. Notably, the addition of silicon is effective to enhance the bioactivity of hydroxyapatite and other biomaterials. The present work aims to expand the knowledge of the role exerted by hydrogen in the biological interaction of silicon-based materials, comparing two hydrogenated amorphous silicon coatings, with different hydrogen content, as means to enhance soft tissue cell adhesion. To accomplish this task, the films were produced by plasma enhanced chemical vapor deposition (PECVD) on titanium substrates and their surface composition and hydrogen content were analyzed by means of X-ray photoelectron spectroscopy (XPS) and Fourier-transform infrared spectrophotometry (FTIR) respectively. The surface energy and roughness were measured through optical contact angle analysis (OCA) and high-resolution mechanical profilometry respectively. Coated surfaces showed a slightly lower roughness, compared to bare titanium samples, regardless of the hydrogen content. The early cell responses of human keratinocytes and fibroblasts were tested on the above mentioned surface modifications, in terms of cell adhesion, viability and morphometrical assessment. Films with lower hydrogen content were endowed with a surface energy comparable to the titanium surfaces. Films with higher hydrogen incorporation displayed a lower surface oxidation and a considerably lower surface energy, compared to the less hydrogenated samples. As regards mean cell area and focal adhesion density, both a-Si coatings influenced fibroblasts, but had no significant effects on keratinocytes. On the contrary, hydrogen-rich films increased manifolds the adhesion and viability of keratinocytes, but not of fibroblasts, suggesting a selective biological effect on these cells.

  15. Platelet‑rich plasma promotes the migration and invasion of synovial fibroblasts in patients with rheumatoid arthritis.

    PubMed

    Yan, Shanshan; Yang, Binzhou; Shang, Chen; Ma, Zhongshuang; Tang, Zizheng; Liu, Guiping; Shen, Weigan; Zhang, Yu

    2016-09-01

    Platelet-rich plasma (PRP) is blood plasma that has been enriched with platelets, and the number of platelets is correlated with rheumatoid activity. PRP is a concentrated source of autologous platelets, and contains several different growth factors and cytokines, including platelet‑derived growth factor, transforming growth factor‑β and insulin‑like growth factor‑1, which stimulate healing of bone and soft tissue. Rheumatoid arthritis (RA) is characterized by synovial hyperplasia, cell activation, articular inflammation and invasion of the synovium into the adjacent bone and cartilage. The adhesion of fibroblast‑like synoviocytes (FLSs) onto the extracellular matrix (ECM), migration and invasion are important for the erosion and destruction of the articular cartilage of patients with RA. The aim of the present study was to investigate the effects of PRP on the adhesion, migration and invasion of RA‑FLSs. Scratch and Transwell migration assays determined that PRP at a concentration of 2 and 5% significantly enhanced the migration ability of RA‑FLSs. Treatment of RA‑FLSs with 2 and 5% PRP promoted the adhesion and invasion of the cells. Additionally, the immunofluorescence assay revealed that PRP induced a decrease in the number of centrally located stress fibers and led to an increase in the formation of filopodia and lamellipodia in the detectable leading edge protrusions in RA‑FLSs. In addition, reverse transcription‑quantitative polymerase chain reaction and western blot analysis determined that PRP upregulated the protein and mRNA expression levels of matrix metalloproteinase‑1 (MMP‑1). In conclusion, the promotion of RA‑FLS cell migration, invasion and adhesion on the ECM by PRP may be modulated through the upregulation of MMP‑1 expression and the induction of actin cytoskeletal reorganization.

  16. 3D MRI Modeling of Thin and Spatially Complex Soft Tissue Structures without Shrinkage: Lamprey Myosepta as an Example.

    PubMed

    Wood, Bradley M; Jia, Guang; Carmichael, Owen; McKlveen, Kevin; Homberger, Dominique G

    2018-05-12

    3D imaging techniques enable the non-destructive analysis and modeling of complex structures. Among these, MRI exhibits good soft tissue contrast, but is currently less commonly used for non-clinical research than x-ray CT, even though the latter requires contrast-staining that shrinks and distorts soft tissues. When the objective is the creation of a realistic and complete 3D model of soft tissue structures, MRI data are more demanding to acquire and visualize and require extensive post-processing because they comprise non-cubic voxels with dimensions that represent a trade-off between tissue contrast and image resolution. Therefore, thin soft tissue structures with complex spatial configurations are not always visible in a single MRI dataset, so that standard segmentation techniques are not sufficient for their complete visualization. By using the example of the thin and spatially complex connective tissue myosepta in lampreys, we developed a workflow protocol for the selection of the appropriate parameters for the acquisition of MRI data and for the visualization and 3D modeling of soft tissue structures. This protocol includes a novel recursive segmentation technique for supplementing missing data in one dataset with data from another dataset to produce realistic and complete 3D models. Such 3D models are needed for the modeling of dynamic processes, such as the biomechanics of fish locomotion. However, our methodology is applicable to the visualization of any thin soft tissue structures with complex spatial configurations, such as fasciae, aponeuroses, and small blood vessels and nerves, for clinical research and the further exploration of tensegrity. This article is protected by copyright. All rights reserved. © 2018 Wiley Periodicals, Inc.

  17. Components of soft tissue deformations in subjects with untreated angle's Class III malocclusions: thin-plate spline analysis.

    PubMed

    Singh, G D; McNamara, J A; Lozanoff, S

    1998-01-01

    While the dynamics of maxillo-mandibular allometry associated with treatment modalities available for the management of Class III malocclusions currently are under investigation, developmental aberration of the soft tissues in untreated Class III malocclusions requires specification. In this study, lateral cephalographs of 124 prepubertal European-American children (71 with untreated Class III malocclusion; 53 with Class I occlusion) were traced, and 12 soft-tissue landmarks digitized. Resultant geometries were scaled to an equivalent size and mean Class III and Class I configurations compared. Procrustes analysis established statistical difference (P < 0.001) between the mean configurations. Comparing the overall untreated Class III and Class I configurations, thin-plate spline (TPS) analysis indicated that both affine and non-affine transformations contribute towards the deformation (total spline) of the averaged Class III soft tissue configuration. For non-affine transformations, partial warp 8 had the highest magnitude, indicating large-scale deformations visualized as a combination of columellar retrusion and lower labial protrusion. In addition, partial warp 5 also had a high magnitude, demonstrating upper labial vertical compression with antero-inferior elongation of the lower labio-mental soft tissue complex. Thus, children with Class III malocclusions demonstrate antero-posterior and vertical deformations of the maxillary soft tissue complex in combination with antero-inferior mandibular soft tissue elongation. This pattern of deformations may represent gene-environment interactions, resulting in Class III malocclusions with characteristic phenotypes, that are amenable to orthodontic and dentofacial orthopedic manipulations.

  18. Reverse radial artery flap for soft tissue defects of hand in pediatric age group.

    PubMed

    Cheema, Saeed Ashraf; Talaat, Nabeela

    2009-01-01

    To highlight the usefulness of reverse radial artery flap in covering various soft tissue defects of hand in paediatric age group. A total of 16 reverse radial artery flaps were utilized in a period of three years to cover various soft tissue defects of hand for paediatric age group patients. The age ranged from 5-18 years. The two common causes of soft tissue defects in this series were mechanical trauma and fireworks trauma with five cases in each group. Three of the cases were burn victims and other two presented with earth quake injuries. One patient had wound because of road traffic accident. Soft tissue defects of palm were covered with this flap in eight cases while in three cases it was wrapped around the thumb. First web space defects were covered with this flap in two cases. Two cases required coverage of amputation stump at transmetacarpal level and yet another required a big flap to cover the soft tissue defects at palm, dorsum and thumb. Donor site was covered with split skin graft in all cases but one, which was closed primarily. We had partial loss of flap in one case. Grafted donor sites healed uneventfully and were quite acceptable to the patients in due course of time. Reverse radial artery flap has a quite long arc of rotation which brings it great ease to cover the soft tissue defects of various areas of hand like palm, dorsum, first web space and thumb.

  19. Myoepithelial carcinoma on the right shoulder: Case report with published work review.

    PubMed

    Yokose, Chiharu; Asai, Jun; Kan, Saori; Nomiyama, Tomoko; Takenaka, Hideya; Konishi, Eiichi; Goto, Keisuke; Ansai, Shin-Ichi; Katoh, Norito

    2016-09-01

    Myoepithelial carcinoma is a malignant tumor that can differentiate towards myoepithelial cells and commonly occur in the salivary glands. There have been only a few reports of primary cutaneous myoepithelial carcinoma; however, most cases showed subcutaneous involvement and could also be diagnosed as soft tissue myoepithelial carcinoma arising from the subcutis with dermal involvement. It may thus be impossible to distinguish a primary cutaneous from a soft tissue myoepithelial carcinoma. Herein, we describe a case of myoepithelial carcinoma on the shoulder in an 85-year-old Japanese woman. The tumor was located in the whole dermis and subcutis; therefore, it could be diagnosed as either a cutaneous or soft tissue myoepithelial carcinoma. We reviewed previous cases of primary cutaneous and soft tissue myoepithelial carcinomas and compared their clinical and immunohistological features. We found no obvious differences in anatomical distribution or immunohistochemical findings. However, the recurrence rate of cutaneous myoepithelial carcinomas seems to be lower than that of soft tissue carcinomas. Such a difference may be attributable to the adequate surgical margin in cutaneous carcinomas compared with the deep-seated soft tissue carcinomas. The metastatic frequency did not significantly differ between the two types. Although we could summarize from only a small number of cases, these results indicate the difficulty in distinguishing between cutaneous and soft tissue myoepithelial carcinomas; furthermore, it may not be suitable to distinguish them on the basis of aggressive behavior. © 2016 Japanese Dermatological Association.

  20. Xenogeneic collagen matrix versus connective tissue graft for buccal soft tissue augmentation at implant site. A randomized, controlled clinical trial.

    PubMed

    Cairo, Francesco; Barbato, Luigi; Tonelli, Paolo; Batalocco, Guido; Pagavino, Gabriella; Nieri, Michele

    2017-07-01

    Peri-implant soft tissue may be critical to prevent inflammation and promote gingival margin stability. The purpose of this randomized clinical trial (RCT) is to compare xenogeneic collagen matrix (XCM) versus connective tissue graft (CTG) to increase buccal soft tissue thickness at implant site. Soft tissue augmentation with XCM (test) or CTG (control) was performed at 60 implants in 60 patients at the time of implant uncovering. Measurements were performed by a blinded examiner at baseline, 3 and 6 months. Outcome measures included buccal soft tissue thickness (GT), apico-coronal keratinized tissue (KT), chair time and post-operative discomfort. Visual Analogue Scale (VAS) was used to evaluate patient satisfaction. After 6 months, the final GT increase was 0.9 ± 0.2 in the XCM group and 1.2 ± 0.3 mm in the CTG group, with a significant difference favouring the control group (0.3 mm; p = .0001). Both procedures resulted in similar final KT amount with no significant difference between treatments. XCM was associated with significant less chair-time (p < .0001), less post-operative pain (p < .0001), painkillers intake (p < .0001) and higher final satisfaction than CTG (p = .0195). CTG was more effective than XCM to increase buccal peri-implant soft tissue thickness. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Comparative anatomy and histology of xenarthran osteoderms.

    PubMed

    Hill, Robert V

    2006-12-01

    Reconstruction of soft tissues in fossil vertebrates is an enduring challenge for paleontologists. Because inferences must be based on evidence from hard tissues (typically bones or teeth), even the most complete fossils provide only limited information about certain organ systems. Osteoderms ("dermal armor") are integumentary bones with high fossilization potential that hold information about the anatomy of the skin in many extant and fossil amniotes. Their importance for functional morphology and phylogenetic research has recently been recognized, but studies have focused largely upon reptiles, in which osteoderms are most common. Among mammals, osteoderms occur only in members of the clade Xenarthra, which includes armadillos and their extinct relatives: glyptodonts, pampatheres, and, more distantly, ground sloths. Here, I present new information on the comparative morphology and histology of osteoderms and their associated soft tissues in 11 extant and fossil xenarthrans. Extinct mylodontid sloths possessed simple, isolated ossicles, the presence of which is likely plesiomorphic for Xenarthra. More highly derived osteoderms of glyptodonts, pampatheres, and armadillos feature complex articulations and surface ornamentation. Osteoderms of modern armadillos are physically associated with a variety of soft tissues, including nerve, muscle, gland, and connective tissue. In some cases, similar osteological features may be caused by two or more different tissue types, rendering soft-tissue inferences for fossil osteoderms equivocal. Certain osteological structures, however, are consistently associated with specific soft-tissue complexes and therefore represent a relatively robust foundation upon which to base soft-tissue reconstructions of extinct xenarthrans. Copyright 2006 Wiley-Liss, Inc.

  2. Biodegradable and thermosensitive monomethoxy poly(ethylene glycol)-poly(lactic acid) hydrogel as a barrier for prevention of post-operative abdominal adhesion.

    PubMed

    Fu, Shao Zhi; Li, Zhi; Fan, Jun Ming; Meng, Xiao Hang; Shi, Kun; Qu, Ying; Yang, Ling Lin; Wu, Jing Bo; Fan, Juan; Luot, Feng; Qian, Zhi Yong

    2014-03-01

    Post-operative peritoneal adhesions are serious consequences of abdominal or pelvic surgery and cause severe bowel obstruction, chronic pelvic pain and infertility. In this study, a novel nano-hydrogel system based on a monomethoxy poly(ethylene glycol)-poly(lactic acid) (MPEG-PLA) di-block copolymer was studied for its ability to prevent abdominal adhesion in rats. The MPEG-PLA hydrogel at a concentration of 40% (w/v) was injected and was able to adhere to defect sites at body temperature. The ability of the hydrogel to inhibit adhesion of post-operative tissues was evaluated by utilizing a rat model of abdominal sidewall-cecum abrasion. It was possible to heal wounded tissue through regeneration of neo-peritoneal tissues ten days after surgery. Our data showed that this hydrogel system is equally as effective as current commercialized anti-adhesive products.

  3. Multifunctional Self-Adhesive Fibrous Layered Matrix (FiLM) for Tissue Glues and Therapeutic Carriers.

    PubMed

    Yoon, Ye-Eun; Im, Byung Gee; Kim, Jung-Suk; Jang, Jae-Hyung

    2017-01-09

    Tissue adhesives, which inherently serve as wound sealants or as hemostatic agents, can be further augmented to acquire crucial functions as scaffolds, thereby accelerating wound healing or elevating the efficacy of tissue regeneration. Herein, multifunctional adherent fibrous matrices, acting as self-adhesive scaffolds capable of cell/gene delivery, were devised by coaxially electrospinning poly(caprolactone) (PCL) and poly(vinylpyrrolidone) (PVP). Wrapping the building block PCL fibers with the adherent PVP layers formed film-like fibrous matrices that could rapidly adhere to wet biological surfaces, referred to as fibrous layered matrix (FiLM) adhesives. The inclusion of ionic salts (i.e., dopamine hydrochloride) in the sheath layers generated spontaneously multilayered fibrous adhesives, whose partial layers could be manually peeled off, termed derivative FiLM (d-FiLM). In the context of scaffolds/tissue adhesives, both FiLM and d-FiLM demonstrated almost identical characteristics (i.e., sticky, mechanical, and performances as cell/gene carriers). Importantly, the single FiLM-process can yield multiple sets of d-FiLM by investing the same processing time, materials, and labor required to form a single conventional adhesive fibrous mat, thereby highlighting the economic aspects of the process. The FiLM/d-FiLM offer highly impacting contributions to many biomedical applications, especially in fields that require urgent aids (e.g., endoscopic surgeries, implantation in wet environments, severe wounds).

  4. Species specificity in cell-substrate interactions in medusae.

    PubMed

    Schmid, V; Bally, A

    1988-10-01

    A new system is described for the study of ECM-tissue interactions, using the ECM (called mesogloea) of various cnidarians and isolated striated muscle and endodermal tissue of jellyfish. The mesogloea consists mainly of water and collagen. It is present in all cnidarians and can be isolated without enzyme treatment. It can be used as a substrate to which cells and tissues adhere and on which they spread and migrate. Tissues of striated muscle and endoderm adhere and spread not only on mesogloea from regions they normally cover, but also from other regions of the animal. However, adhesion and spreading are highly species-specific. Species-specific adhesion is found throughout the whole mass of mesogloea even at regions where cells do not occur naturally. The cell adhesion factor can be extracted from the mesogloea so that the mesogloea no longer shows any cell adhesion properties. The extract consists mainly of a cysteine-containing collagen.

  5. Fibrin tissue adhesive and autologous concha cartilage for reconstruction of the posterior-superior canal wall of the chinchilla middle ear.

    PubMed

    Siedentop, Karl H; O'Grady, Kevin; Bhattacharyya, Tapan K; Shah, Ami

    2004-05-01

    We conducted this study to prove that fibrin tissue adhesive (FTA) is safe, efficacious, biocompatible, and readily biodegradable with no deleterious side effects for fixation of a cartilage graft to bone along the chinchilla canal wall. A posterior-superior canal defect was created in 12 chinchillas. The canal walls of six chinchillas were closed with autologous concha cartilage alone, whereas the canal wall of the remaining six animals were closed with cartilage in conjunction with fibrin tissue adhesive. Animals were killed 8 weeks postoperatively. Three of six cartilage grafts were displaced in the graft alone group, whereas all six grafts in the cartilage with FTA group healed without displacement. Fibrin tissue adhesive was found to be effective, biocompatible, biodegradable, and without any deleterious side effects for reconstruction of the superior-posterior canal wall of chinchillas.

  6. Intra-oral soft tissue expansion and volume stability of onlay bone grafts.

    PubMed

    Abrahamsson, Peter

    2011-01-01

    Insufficient regeneration of missing bone and soft-tissue may present aesthetic or functional problems in patients indicated for dental implant surgery. Several techniques such as bone grafts, bone substitutes and guided tissue regeneration (GTR) have been described to rebuild a compromised alveolar ridge. Adequate soft-tissue coverage of grafted bone and titanium-mesh is important to avoid exposure which may result in loss of the bone graft. The general aim of this thesis was to evaluate use of an osmotic tissue expander for expanding intra-oral soft tissue--creating a surplus of soft tissue-- in preparation for onlay bone grafting. An experimental rabbit model was used in studies (I), (II) and (III). In (I) an osmotic soft-tissue expander was placed bilaterally on the lateral wall of the mandible via an extra-oral approach. After two weeks of expansion the rabbits were killed and specimens were collected for histology. No inflammatory reaction and no resorbtion of the cortical bone occured. The periosteum was expanded and new bone formation was seen in the edges of the expander. In (II) and (III) the expander was placed under the periosteum in the same way as in (I): bilaterally in 13 rabbits in (II) and unilaterally in 11 rabbits in (III). After two weeks of expansion the expander was identified and removed. In (II) particulated bone was placed at the recipient site protected by a titanium mesh in one site and a bio-resorbable mesh on the other site. In (III), DBBM particles and bone particles collected from the lateral border of the mandible separated by a collagen membrane was placed at the recipient site. The graft was protected by a pre-bent titanium mesh covered by a collagen membrane. After a healing period of 3 months specimens were collected for histological and SEM examination. New bone was growing in direct contact with the titanium mesh and bio resorbable mesh. The newly formed bone had the same calcium content as the mature bone in the base of the mandible. In the clinical study (IV) 20 patients were consecutively recruited and randomised into two groups. The experimental group (ten patients) had an osmotic soft tissue expander implanted. After two weeks of expansion the expander was removed and a particulated bone graft protected by a titanium mesh and a collagen membrane was fixed to the recipient site. Titanium implants were installed after a healing period of 6 months. The patients in the reference group had a bone block grafted from the anterior ramus fixated to the recipient site with one or two titanium mini screws. Implants were installed after a healing period of 6 months. A three dimensional optical measuring device was used to measure alterations in the soft tissue profile before each surgical procedure. The three-dimensional changes were then analysed on a PC. The results from the clinical study in patients confirmed the results from the experimental rabbit studies. The osmotic tissue expander expanded the soft tissue. Expander perforations of the soft tissue occurred in two patients. The optical measurements demonstrated a positive volume gain after soft tissue expansion and bone grafting. The expanded tissue could be used to cover a bone graft. There still was a risk of mesh exposure, even after soft tissue expansion, which occurred in two patients. In both groups, implants could be installed in the grafted bone in positions that would allow the crowns to fit aesthetically into the dental arch.

  7. Bifurcations: Focal Points of Particle Adhesion in Microvascular Networks

    PubMed Central

    Prabhakarpandian, Balabhaskar; Wang, Yi; Rea-Ramsey, Angela; Sundaram, Shivshankar; Kiani, Mohammad F.; Pant, Kapil

    2011-01-01

    Objective Particle adhesion in vivo is dependent on microcirculation environment which features unique anatomical (bifurcations, tortuosity, cross-sectional changes) and physiological (complex hemodynamics) characteristics. The mechanisms behind these complex phenomena are not well understood. In this study, we used a recently developed in vitro model of microvascular networks, called Synthetic Microvascular Network, for characterizing particle adhesion patterns in the microcirculation. Methods Synthetic microvascular networks were fabricated using soft lithography processes followed by particle adhesion studies using avidin and biotin-conjugated microspheres. Particle adhesion patterns were subsequently analyzed using CFD based modeling. Results Experimental and modeling studies highlighted the complex and heterogeneous fluid flow patterns encountered by particles in microvascular networks resulting in significantly higher propensity of adhesion (>1.5X) near bifurcations compared to the branches of the microvascular networks. Conclusion Bifurcations are the focal points of particle adhesion in microvascular networks. Changing flow patterns and morphology near bifurcations are the primary factors controlling the preferential adhesion of functionalized particles in microvascular networks. Synthetic microvascular networks provide an in vitro framework for understanding particle adhesion. PMID:21418388

  8. A relatively small change in sodium chloride concentration has a strong effect on adhesion of ocular bacteria to contact lenses.

    PubMed

    Cowell, B A; Willcox, M D; Schneider, R P

    1998-06-01

    Adhesion of bacteria to hydrogel lenses is thought to be an initial step of ocular colonization allowing evasion of normal host defences. The salt concentration of media is an important parameter controlling microbial adhesion. Salinity varies from 0.97% NaCl equivalents in the open eye to 0.89% in the closed eye state. In this study, the effect of sodium chloride in the concentration range of 0.8-1.0% (w/v) NaCl on adhesion of ocular bacteria to soft contact lenses was investigated using a static adhesion assay. Pseudomonas aeruginosa was found to adhere to lenses in significantly greater amounts than Serratia marcescens, Flavobacterium meningosepticum, Stenotrophomonas maltophilia and Staphylococcus intermedius. Increasing NaCl from 0.8% to 1.0% (w/v) increased adhesion of all bacteria tested. This adhesion was strong since the organisms could not be removed by washing in low ionic buffer. Adhesion of these organisms did not correlate with their cell surface properties as determined by bacterial adhesion to hydrocarbons (BATH) and retention on sepharose columns.

  9. Adhesive interactions of biologically inspired soft condensed matter

    NASA Astrophysics Data System (ADS)

    Anderson, Travers Heath

    Improving our fundamental understanding of the surface interactions between complex materials is needed to improve existing materials and products as well as develop new ones. The object of this research was to apply the measurements of fundamental surface interactions to real world problems facing chemical engineers and materials scientists. I focus on three systems of biologically inspired soft condensed matter, with an emphasis on the adhesive interactions between them. The formation of phospholipid bilayers of the neutral lipid, dimyristoyl-phosphatidylcholine (DMPC) on silica surfaces from vesicles in aqueous solutions was investigated. The process involves five stages: vesicle adhesion to the substrate surfaces, steric interactions with neighboring vesicles, rupture, spreading via hydrophobic fusion of bilayer edges, and ejection of excess lipid, trapped water and ions into the solution. The forces between DMPC bilayers and silica were measured in the Surface Forces Apparatus (SFA) in phosphate buffered saline. The adhesion energy was found to be much stronger than the expected adhesion predicted by van der Waals interactions, likely due to an attractive electrostatic interaction. The effects of non-adsorbing cationic polyelectrolytes on the interactions between supported cationic surfactant bilayers were studied using the SFA. Addition of polyelectrolyte has a number of effects on the interactions including the induction of a depletion-attraction and screening of the double-layer repulsion. Calculations are made that allow for the conversion of the adhesion energy measured in the SFA to the overall interaction energy between vesicles in solution, which determines the stability behavior of vesicle dispersions. Mussels use a variety of dihydroxyphenyl-alanine (DOPA) rich proteins specifically tailored to adhering to wet surfaces. The SFA was used to study the role of DOPA on the adhesive properties of these proteins to TiO 2 and mica using both real mussel foot proteins (mfp) and a synthetic polypeptide analogue of mfp-3. Adhesion increased with DOPA concentration, although oxidation of DOPA reduces the adhesive capabilities of the proteins. Comparison of the two shows that DOPA is responsible for at least 80% of the adhesion energy of mfp-3 and can be attributed to DOPA groups favorably oriented within or at the interface of these films.

  10. Impact of timing on soft tissue augmentation during implant treatment: A systematic review and meta-analysis.

    PubMed

    Lin, Cho-Ying; Chen, Zhaozhao; Pan, Whei-Lin; Wang, Hom-Lay

    2018-05-01

    To achieve a predictable esthetic and functional outcome, soft tissue augmentation has become popular in implant treatment. The aim of this systematic review and meta-analysis was to assess the influence of different timing for soft tissue augmentation during implant treatment on soft tissue conditions and its stability. Electronic and manual searches for articles written in English up to September 2017 were performed by two independent reviewers. Human clinical studies with the purpose of evaluating outcomes (at least 3-month follow-up) of autogenous soft tissue graft for augmentation during implant treatment, either simultaneous or after implant placement (staged), were included. Cumulative changes of keratinized tissue width (KTW), soft tissue thickness (STT), and mid-buccal mucosal recession (MR) data were analyzed with a random-effects model to compare the postoperative outcomes. Twenty-nine human studies (eight randomized clinical trials, six cohort studies, and 15 case series) that met the inclusion criteria were included. For the overall data, the weighted mean STT gain (1 year after surgery) was 1.03 mm (95% CI: 0.78-1.29 mm), among which the simultaneous group was 1.12 mm (95% CI: 0.75-1.49 mm) and staged group (3-6 months after implant placement) was 0.95 mm (95% CI: 0.58-1.31 mm). There was no statistically significant difference in KTW and MR between 3 months and more than 3 months after surgery. This review revealed that the stability of soft tissue, in terms of KTW and mid-buccal MR, can be obtained 3 months after surgery. There is no difference between simultaneous and staged soft tissue augmentation during implant treatment, and both procedures significantly enhance KTW and STT. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. From elasticity to capillarity in soft materials indentation

    NASA Astrophysics Data System (ADS)

    Pham, Jonathan T.; Schellenberger, Frank; Kappl, Michael; Butt, Hans-Jürgen

    2017-06-01

    For soft materials with Young's moduli below 100 kPa, quantifying mechanical and interfacial properties by small scale indentation is challenging because in addition to adhesion and elasticity, surface tension plays a critical role. Until now, microscale contact of very soft materials has only been studied by static experiments under zero external loading. Here we introduce a combination of the colloidal probe technique and confocal microscopy to characterize the force-indentation and force-contact radius relationships during microindentation of soft silicones. We confirm that the widespread Johnson-Kendall-Roberts theory must be extended to predict the mechanical contact for soft materials. Typically a liquid component is found within very soft materials. With a simple analytical model, we illustrate that accounting for this liquid surface tension can capture the contact behavior. Our results highlight the importance of considering liquid that is often associated with soft materials during small scale contact.

  12. Development of a fast curing tissue adhesive for meniscus tear repair.

    PubMed

    Bochyńska, Agnieszka Izabela; Hannink, Gerjon; Janssen, Dennis; Buma, Pieter; Grijpma, Dirk W

    2017-01-01

    Isocyanate-terminated adhesive amphiphilic block copolymers are attractive materials to treat meniscus tears due to their tuneable mechanical properties and good adhesive characteristics. However, a drawback of this class of materials is their relatively long curing time. In this study, we evaluate the use of an amine cross-linker and addition of catalysts as two strategies to accelerate the curing rates of a recently developed biodegradable reactive isocyanate-terminated hyper-branched adhesive block copolymer prepared from polyethylene glycol (PEG), trimethylene carbonate, citric acid and hexamethylene diisocyanate. The curing kinetics of the hyper-branched adhesive alone and in combination with different concentrations of spermidine solutions, and after addition of 2,2-dimorpholinodiethylether (DMDEE) or 1,4-diazabicyclo [2.2.2] octane (DABCO) were determined using FTIR. Additionally, lap-shear adhesion tests using all compositions at various time points were performed. The two most promising compositions of the fast curing adhesives were evaluated in a meniscus bucket handle lesion model and their performance was compared with that of fibrin glue. The results showed that addition of both spermidine and catalysts to the adhesive copolymer can accelerate the curing rate and that firm adhesion can already be achieved after 2 h. The adhesive strength to meniscus tissue of 3.2-3.7 N was considerably higher for the newly developed compositions than for fibrin glue (0.3 N). The proposed combination of an adhesive component and a cross-linking component or catalyst is a promising way to accelerate curing rates of isocyanate-terminated tissue adhesives.

  13. Cell-cell and cell-extracellular matrix adhesions cooperate to organize actomyosin networks and maintain force transmission during dorsal closure.

    PubMed

    Goodwin, Katharine; Lostchuck, Emily E; Cramb, Kaitlyn M L; Zulueta-Coarasa, Teresa; Fernandez-Gonzalez, Rodrigo; Tanentzapf, Guy

    2017-05-15

    Tissue morphogenesis relies on the coordinated action of actin networks, cell-cell adhesions, and cell-extracellular matrix (ECM) adhesions. Such coordination can be achieved through cross-talk between cell-cell and cell-ECM adhesions. Drosophila dorsal closure (DC), a morphogenetic process in which an extraembryonic tissue called the amnioserosa contracts and ingresses to close a discontinuity in the dorsal epidermis of the embryo, requires both cell-cell and cell-ECM adhesions. However, whether the functions of these two types of adhesions are coordinated during DC is not known. Here we analyzed possible interdependence between cell-cell and cell-ECM adhesions during DC and its effect on the actomyosin network. We find that loss of cell-ECM adhesion results in aberrant distributions of cadherin-mediated adhesions and actin networks in the amnioserosa and subsequent disruption of myosin recruitment and dynamics. Moreover, loss of cell-cell adhesion caused up-regulation of cell-ECM adhesion, leading to reduced cell deformation and force transmission across amnioserosa cells. Our results show how interdependence between cell-cell and cell-ECM adhesions is important in regulating cell behaviors, force generation, and force transmission critical for tissue morphogenesis. © 2017 Goodwin, Lostchuck, et al. This article is distributed by The American Society for Cell Biology under license from the author(s). Two months after publication it is available to the public under an Attribution–Noncommercial–Share Alike 3.0 Unported Creative Commons License (http://creativecommons.org/licenses/by-nc-sa/3.0).

  14. Watertight cataract incision closure using fibrin tissue adhesive.

    PubMed

    Hovanesian, John A; Karageozian, Vicken H

    2007-08-01

    To determine whether a simple method for applying fibrin tissue adhesive to a clear corneal cataract incision can create a watertight seal. Laboratory investigation. Clear corneal cataract incisions were simulated in 8 eye-bank eyes. In 4 eyes, fibrin adhesive was applied to the incision in a simple manner; the other 4 eyes were controls with no adhesive. Each eye was tested under low pressure conditions to detect fluid ingress of India Ink on the eye's surface. The eyes were tested again with external compression to distort the incision to detect fluid egress. In the eyes with fibrin adhesive, there was no egress of fluid with incision distortion and no ingress of India Ink. In the 4 eyes without adhesive, there was ingress and egress of fluid. A simple method of applying fibrin adhesive to cataract incisions created a watertight seal.

  15. Soft tissue recurrence of giant cell tumor of the bone: Prevalence and radiographic features.

    PubMed

    Xu, Leilei; Jin, Jing; Hu, Annan; Xiong, Jin; Wang, Dongmei; Sun, Qi; Wang, Shoufeng

    2017-11-01

    Recurrence of giant cell tumor of bone (GCTB) in the soft tissue is rarely seen in the clinical practice. This study aims to determine the prevalence of soft tissue recurrence of GCTB, and to characterize its radiographic features. A total of 291 patients treated by intralesional curettage for histologically diagnosed GCTB were reviewed. 6 patients were identified to have the recurrence of GCTB in the soft tissue, all of whom had undergone marginal resection of the lesion. Based on the x-ray, CT and MRI imaging, the radiographic features of soft tissue recurrence were classified into 3 types. Type I was defined as soft tissue recurrence with peripheral ossification, type II was defined as soft tissue recurrence with central ossification, and type III was defined as pure soft tissue recurrence without ossification. Demographic data including period of recurrence and follow-up duration after the second surgery were recorded for these 6 patients. Musculoskeletal Tumor Society (MSTS) scoring system was used to evaluate functional outcomes. The overall recurrence rate was 2.1% (6/291). The mean interval between initial surgery and recurrence was 11.3 ± 4.1 months (range, 5-17). The recurrence lesions were located in the thigh of 2 patients, in the forearm of 2 patients and in the leg of the other 2 patients. According to the classification system mentioned above, 2 patients were classified with type I, 1 as type II and 3 as type III. After the marginal excision surgery, all patients were consistently followed up for a mean period of 13.4 ± 5.3 months (range, 6-19), with no recurrence observed at the final visit. All the patients were satisfied with the surgical outcome. According to the MSTS scale, the mean postoperative functional score was 28.0 ± 1.2 (range, 26-29). The classification of soft tissue recurrence of GCTB may be helpful for the surgeon to select the appropriate imaging procedure to detect the recurrence. In addition, the marginal resection can produce a favorable outcome for the patients.

  16. SU-E-J-203: Investigation of 1.5T Magnetic Field Dose Effects On Organs of Different Density

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, H; Rubinstein, A; Ibbott, G

    2015-06-15

    Purpose: For the combined 1.5T/6MV MRI-linac system, the perpendicular magnetic field to the radiation beam results in altered radiation dose distributions. This Monte Carlo study investigates the change in dose at interfaces for common organs neighboring soft tissue. Methods: MCNP6 was used to simulate the effects of a 1.5T magnetic field when irradiating tissues with a 6 MV beam. The geometries used in this study were not necessarily anatomically representative in size in order to directly compare quantitative dose effects for each tissue at the same depths. For this purpose, a 512 cm{sup 3} cubic material was positioned at themore » center of a 2744 cm{sup 3} cubic soft tissue material phantom. The following tissue materials and their densities were used in this study: lung (0.296 g/cm{sup 3}), fat (0.95), spinal cord (1.038), soft tissue (1.04), muscle (1.05), eye (1.076), trabecular bone (1.40), and cortical bone (1.85). Results: The addition of a 1.5T magnetic field caused dose changes of +46.5%, +2.4%, −0.9%, −0.8%, −1.5%, −6.5%, and −8.8% at the entrance interface between soft tissue and lung, fat, spinal cord, muscle, eye, trabecular bone, and cortical bone tissues respectively. Dose changes of −39.4%, −4.1%, −0.8%, −0.8%, +0.5%, +6.7%, and +10.9% were observed at the second interface between the same tissues respectively and soft tissue. On average, the build-up distance was reduced by 0.6 cm, and a dose increase of 62.7% was observed at the exit interface between soft tissue and air of the entire phantom. Conclusion: The greatest changes in dose were observed at interfaces containing lung and bone tissues. Due to the prevalence and proximity of bony anatomy to soft tissues throughout the human body, these results encourage further examination of these tissues with anatomically representative geometries using multiple beam configurations for safe treatment using the MRI-linac system.« less

  17. DR-nm23 expression affects neuroblastoma cell differentiation, integrin expression, and adhesion characteristics.

    PubMed

    Amendola, R; Martinez, R; Negroni, A; Venturelli, D; Tanno, B; Calabretta, B; Raschellà, G

    2001-01-01

    Nm23 gene family has been associated with metastasis suppression and differentiation. We studied DR-nm23 during neuroblastoma cells differentiation. DR-nm23 expression increased after retinoic acid induction of differentiation in human cell lines SK-N-SH and LAN-5. In several cell lines, overexpression of DR-nm23 was associated with more differentiated phenotypes. SK-N-SH cells increased vimentin expression, increased deposition of collagen type IV, modulated integrin expression, and underwent growth arrest; the murine neuroblastoma cell line N1E-115 showed neurite outgrowth and a striking enhancement of beta1 integrin expression. Up-regulation of beta1 integrin was specifically responsible for the increase in the adhesion to collagen type I-coated plates. Finally, cells overexpressing DR-nm23 were unable to growth in soft agar. In conclusion, DR-nm23 expression is directly involved in differentiation of neuroblastoma cells, and its ability to affects the adhesion to extracellular substrates and to inhibit growth in soft agar suggests an involvement in the metastatic potential of neuroblastoma.

  18. [Magnetic resonance imaging in facial injuries and digital fusion CT/MRI].

    PubMed

    Kozakiewicz, Marcin; Olszycki, Marek; Arkuszewski, Piotr; Stefańczyk, Ludomir

    2006-01-01

    Magnetic resonance images [MRI] and their digital fusion with computed tomography [CT] data, observed in patients affected with facial injuries, are presented in this study. The MR imaging of 12 posttraumatic patients was performed in the same plains as their previous CT scans. Evaluation focused on quality of the facial soft tissues depicting, which was unsatisfactory in CT. Using the own "Dental Studio" programme the digital fusion of the both modalities was performed. Pathologic dislocations and injures of facial soft tissues are visualized better in MRI than in CT examination. Especially MRI properly reveals disturbances in intraorbital soft structures. MRI-based assessment is valuable in patients affected with facial soft tissues injuries, especially in case of orbita/sinuses hernia. Fusion CT/MRI scans allows to evaluate simultaneously bone structure and soft tissues of the same region.

  19. Soft Tissue Grafting Around Teeth and Implants.

    PubMed

    Deeb, George R; Deeb, Janina Golob

    2015-08-01

    The presence of healthy attached tissue at the tooth and implant soft tissue interface correlates with long-term success and stability in function and esthetics. There are several soft tissue grafting procedures that increase the volume of keratinized tissue and provide coverage on both teeth and implants. Many of these techniques can be used in conjunction with implant placement, or after placement as a means of salvage. This article describes the techniques for augmentation of keratinized tissue as well as root and implant coverage. These tools should be in the armamentarium of oral and maxillofacial surgeons providing implant services. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Role of differential physical properties in the collective mechanics and dynamics of tissues

    NASA Astrophysics Data System (ADS)

    Das, Moumita

    Living cells and tissues are highly mechanically sensitive and active. Mechanical stimuli influence the shape, motility, and functions of cells, modulate the behavior of tissues, and play a key role in several diseases. In this talk I will discuss how collective biophysical properties of tissues emerge from the interplay between differential mechanical properties and statistical physics of underlying components, focusing on two complementary tissue types whose properties are primarily determined by (1) the extracellular matrix (ECM), and (2) individual and collective cell properties. I will start with the structure-mechanics-function relationships in articular cartilage (AC), a soft tissue that has very few cells, and its mechanical response is primarily due to its ECM. AC is a remarkable tissue: it can support loads exceeding ten times our body weight and bear 60+ years of daily mechanical loading despite having minimal regenerative capacity. I will discuss the biophysical principles underlying this exceptional mechanical response using the framework of rigidity percolation theory, and compare our predictions with experiments done by our collaborators. Next I will discuss ongoing theoretical work on how the differences in cell mechanics, motility, adhesion, and proliferation in a co-culture of breast cancer cells and healthy breast epithelial cells may modulate experimentally observed differential migration and segregation. Our results may provide insights into the mechanobiology of tissues with cell populations with different physical properties present together such as during the formation of embryos or the initiation of tumors. This work was partially supported by a Cottrell College Science Award.

  1. An inexpensive alternative to routine section adhesives for histology: the mucilaginous substance of the Assyrian plum.

    PubMed

    Al-Shammary, Hayfaa A

    2014-05-01

    We found that the mucilaginous substance of the Assyrian plum, Cordia myxa, can be used as an adhesive for attaching sections of animal tissues to slides. Unlike Mayer's albumen, this material left no stainable residue and had no noticeable effect on the histological structure of the tissue sections. The mucilaginous substance of C. myxa is a useful and inexpensive alternative to standard adhesives.

  2. Matrix MetalloProteinases (MMPs) andTissue Inhibitors of MetalloProteinases (TIMPs): positive and negative regulators intumor cell adhesion

    PubMed Central

    Bourboulia, Dimitra; Stetler-Stevenson, William G.

    2010-01-01

    Cells adhere to one another and/or to matrices that surround them. Regulation of cell-cell (intercellular) and cell-matrix adhesion is tightly controlled in normal cells, however, defects in cell adhesion are common in the majority of humancancers. Multilateral communication among tumor cells with the extracellular matrix (ECM) and neighbor cells is accomplished through adhesion molecules, ECM components, proteolytic enzymes and their endogenous inhibitors. There is sufficient evidence to suggest that reduced adherence is a tumor cell propertyengaged during tumor progression. Tumor cells acquire the ability to change shape, detach and easily move through spaces disorganizing the normal tissue architecture. This property is due to changes in expression levels of adhesion molecules and/or due to elevated levels of secreted proteolytic enzymes, including matrix metalloproteinases (MMPs). Among other roles, MMPsdegrade the ECMand, therefore, prepare the path for tumor cells to migrate, invade and spread to distant secondary areas, where they form metastasis. Tissue Inhibitors of Metalloproteinases or TIMPs control MMP activities and, therefore, minimize matrix degradation. Both MMPs and TIMPs are involved in tissue remodeling and decisively regulate tumor cell progression including tumor angiogenesis. In this review, we describe and discuss data that support the important role of MMPs and TIMPs in cancer cell adhesion and tumor progression. PMID:20470890

  3. Practical use of imaging technique for management of bone and soft tissue tumors.

    PubMed

    Miwa, Shinji; Otsuka, Takanobu

    2017-05-01

    Imaging modalities including radiography, computed tomography (CT), and magnetic resonance imaging (MRI) are necessary for the diagnosis of bone and soft tissue tumors. The history of imaging began with the discovery of X-rays in the 19th century. The development of CT, MRI, ultrasonography, and positron emission tomography (PET) have improved the management of bone and soft tissue tumors. X-ray imaging and CT scans enable the evaluation of bone destruction, periosteal reaction, sclerotic changes in lesions, condition of cortical bone, and ossification. MRI enables the assessment of tissue characteristics, tumor extent, and the reactive areas. Functional imaging modalities including 201 thallium ( 201 Tl) scintigraphy can be used to differentiate benign lesions from malignant lesions and to assess chemotherapeutic effects. Real-time assessment of soft tissue tumors by ultrasonography enables accurate and safe performance of surgery and biopsy. This article describes useful imaging modalities and characteristic findings in the management of bone and soft tissue tumors. Copyright © 2017 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  4. Economic comparison of methods of wound closure: wound closure strips vs. sutures and wound adhesives.

    PubMed

    Zempsky, William T; Zehrer, Cindy L; Lyle, Christopher T; Hedbloom, Edwin C

    2005-09-01

    Our objective was to review and assess the treatment of low-tension wounds and evaluate the cost-effectiveness of wound closure methods. We used a health economic model to estimate cost/closure of adhesive wound closure strips, tissue adhesives and sutures. The model incorporated cost-driving variables: application time, costs and the likelihood and costs of dehiscence and infection. The model was populated with variable estimates derived from the literature. Cost estimates and cosmetic results were compared. Parameter values were estimated using national healthcare and labour statistics. Sensitivity analyses were used to verify the results. Our analysis suggests that adhesive wound closure strips had the lowest average cost per laceration ($7.54), the lowest cost per infected laceration ($53.40) and the lowest cost per laceration with dehiscence ($25.40). The costs for sutures were $24.11, $69.91 and $41.91, respectively; the costs for tissue adhesives were $28.77, $74.68 and $46.68, respectively. The cosmetic outcome for all three treatments was equivalent. We conclude adhesive wound closure strips were both a cost-saving and a cost-effective alternative to sutures and tissue adhesives in the closure of low-tension lacerations.

  5. Functional Attachment of Soft Tissues to Bone: Development, Healing, and Tissue Engineering

    PubMed Central

    Lu, Helen H.; Thomopoulos, Stavros

    2014-01-01

    Connective tissues such as tendons or ligaments attach to bone across a multitissue interface with spatial gradients in composition, structure, and mechanical properties. These gradients minimize stress concentrations and mediate load transfer between the soft and hard tissues. Given the high incidence of tendon and ligament injuries and the lack of integrative solutions for their repair, interface regeneration remains a significant clinical challenge. This review begins with a description of the developmental processes and the resultant structure-function relationships that translate into the functional grading necessary for stress transfer between soft tissue and bone. It then discusses the interface healing response, with a focus on the influence of mechanical loading and the role of cell-cell interactions. The review continues with a description of current efforts in interface tissue engineering, highlighting key strategies for the regeneration of the soft tissue–to-bone interface, and concludes with a summary of challenges and future directions. PMID:23642244

  6. Tracheo-bronchial soft tissue and cartilage resonances in the subglottal acoustic input impedance.

    PubMed

    Lulich, Steven M; Arsikere, Harish

    2015-06-01

    This paper offers a re-evaluation of the mechanical properties of the tracheo-bronchial soft tissues and cartilage and uses a model to examine their effects on the subglottal acoustic input impedance. It is shown that the values for soft tissue elastance and cartilage viscosity typically used in models of subglottal acoustics during phonation are not accurate, and corrected values are proposed. The calculated subglottal acoustic input impedance using these corrected values reveals clusters of weak resonances due to soft tissues (SgT) and cartilage (SgC) lining the walls of the trachea and large bronchi, which can be observed empirically in subglottal acoustic spectra. The model predicts that individuals may exhibit SgT and SgC resonances to variable degrees, depending on a number of factors including tissue mechanical properties and the dimensions of the trachea and large bronchi. Potential implications for voice production and large pulmonary airway tissue diseases are also discussed.

  7. Characterization of focal muscle compression under impact loading

    NASA Astrophysics Data System (ADS)

    Butler, B. J.; Sory, D. R.; Nguyen, T.-T. N.; Proud, W. G.; Williams, A.; Brown, K. A.

    2017-01-01

    In modern wars over 70% of combat wounds are to the extremities. These injuries are characterized by disruption and contamination of the limb soft tissue envelope. The extent of this tissue trauma and contamination determine the outcome of the extremity injury. In military injury, common post-traumatic complications at amputation sites include heterotopic ossification (formation of bone in soft tissue), and severe soft tissue and bone infections. We are currently developing a model of soft tissue injury that recreates pathologies observed in combat injuries. Here we present characterization of a controlled focal compression of the rabbit flexor carpi ulnaris (FCU) muscle group. The FCU was previously identified as a suitable site for studying impact injury because its muscle belly can easily be mobilized from the underlying bone without disturbing anatomical alignment in the limb. We show how macroscopic changes in tissue organization, as visualized using optical microscopy, can be correlated with data from temporally resolved traces of loading conditions.

  8. Soft Tissue Closure of Grafted Extraction Sockets in the Anterior Maxilla: A Modified Palatal Pedicle Connective Tissue Flap Technique.

    PubMed

    El Chaar, Edgard; Oshman, Sarah; Cicero, Giuseppe; Castano, Alejandro; Dinoi, Cinzia; Soltani, Leila; Lee, Yoonjung Nicole

    Localized ridge resorption, the consequence of socket collapse, following tooth extraction in the anterior maxilla can adversely affect esthetics, function, and future implant placement. Immediate grafting of extraction sockets may help preserve natural ridge contours, but a lack of available soft tissue can compromise the final esthetic outcome. The presented modified rotated palatal pedicle connective tissue flap is a useful technique for simultaneous soft tissue coverage and augmentation of grafted sockets to improve esthetic outcome. This article delineates its advantages through the presentation of a four-case series using this new technique.

  9. Regeneration of soft and hard tissue periodontal defects.

    PubMed

    Caffesse, Raúl G; de la Rosa, Manuel; Mota, Luis F

    2002-10-01

    Periodontitis is characterized by the formation of periodontal pockets and bone loss. Although the basic treatment emphasizes the control of bacterial plaque, the clinician is confronted with the need to correct soft and/or hard tissue defects that develop as a consequence of the disease. This article reviews the current status of regenerative approaches in treating soft and hard tissue defects (based mainly on findings from our own laboratory) and assessed the global applicability of these procedures. Many different techniques have been suggested to treat those defects with, in general, a high degree of success. From the present knowledge it can be concluded that periodontal soft and hard tissue regeneration is possible. Treatment of areas with localized gingival recession or insufficient keratinized gingiva can be achieved with soft tissue grafts or pedicle flaps, as well as with the use of dermal allografts. The treatment of hard tissue defects around teeth and implants can be approached using different types of bone grafts, guided tissue or bone regeneration, or a combination of these. The predictability of many of these therapies, however, still needs to be improved. Since most of these techniques are sensitive, specific, and expensive, their present universal application is limited.

  10. Soft-Tissue Infections and Their Imaging Mimics: From Cellulitis to Necrotizing Fasciitis.

    PubMed

    Hayeri, Mohammad Reza; Ziai, Pouya; Shehata, Monda L; Teytelboym, Oleg M; Huang, Brady K

    2016-10-01

    Infection of the musculoskeletal system can be associated with high mortality and morbidity if not promptly and accurately diagnosed. These infections are generally diagnosed and managed clinically; however, clinical and laboratory findings sometimes lack sensitivity and specificity, and a definite diagnosis may not be possible. In uncertain situations, imaging is frequently performed to confirm the diagnosis, evaluate the extent of the disease, and aid in treatment planning. In particular, cross-sectional imaging, including computed tomography and magnetic resonance imaging, provides detailed anatomic information in the evaluation of soft tissues due to their inherent high spatial and contrast resolution. Imaging findings of soft-tissue infections can be nonspecific and can have different appearances depending on the depth and anatomic extent of tissue involvement. Although many imaging features of infectious disease can overlap with noninfectious processes, imaging can help establish the diagnosis when combined with the clinical history and laboratory findings. Radiologists should be familiar with the spectrum of imaging findings of soft-tissue infections to better aid the referring physician in managing these patients. The aim of this article is to review the spectrum of soft-tissue infections using a systematic anatomic compartment approach. We discuss the clinical features of soft-tissue infections, their imaging findings with emphasis on cross-sectional imaging, their potential mimics, and clinical management. © RSNA, 2016.

  11. Photoactivated Composite Biomaterial for Soft Tissue Restoration in Rodents and in Humans

    PubMed Central

    Nahas, Zayna; Reid, Branden; Coburn, Jeannine M.; Axelman, Joyce; Chae, Jemin J.; Guo, Qiongyu; Trow, Robert; Thomas, Andrew; Hou, Zhipeng; Lichtsteiner, Serge; Sutton, Damon; Matheson, Christine; Walker, Patricia; David, Nathaniel; Mori, Susumu; Taube, Janis M.; Elisseeff, Jennifer H.

    2015-01-01

    Soft tissue reconstruction often requires multiple surgical procedures that can result in scars and disfiguration. Facial soft tissue reconstruction represents a clinical challenge because even subtle deformities can severely affect an individual’s social and psychological function. We therefore developed a biosynthetic soft tissue replacement composed of poly(ethylene glycol) (PEG) and hyaluronic acid (HA) that can be injected and photocrosslinked in situ with transdermal light exposure. Modulating the ratio of synthetic to biological polymer allowed us to tune implant elasticity and volume persistence. In a small-animal model, implanted photocrosslinked PEG-HA showed a dose-dependent relationship between increasing PEG concentration and enhanced implant volume persistence. In direct comparison with commercial HA injections, the PEG-HA implants maintained significantly greater average volumes and heights. Reversibility of the implant volume was achieved with hyaluronidase injection. Pilot clinical testing in human patients confirmed the feasibility of the transdermal photocrosslinking approach for implantation in abdomen soft tissue, although an inflammatory response was observed surrounding some of the materials. PMID:21795587

  12. Facial soft-tissue fillers conference: assessing the state of the science.

    PubMed

    Rohrich, Rod J; Hanke, C William; Busso, Mariano; Carruthers, Alastair; Carruthers, Jean; Fagien, Steven; Fitzgerald, Rebecca; Glogau, Richard; Greenberger, Phyllis E; Lorenc, Z Paul; Marmur, Ellen S; Monheit, Gary D; Pusic, Andrea; Rubin, Mark G; Rzany, Berthold; Sclafani, Anthony; Taylor, Susan; Weinkle, Susan; McGuire, Michael F; Pariser, David M; Casas, Laurie A; Collishaw, Karen J; Dailey, Roger A; Duffy, Stephen C; Edgar, Elizabeth Jan; Greenan, Barbara L; Haenlein, Kelly; Henrichs, Ronald A; Hume, Keith M; Lum, Flora; Nielsen, David R; Poulsen, Lisle; Shoaf, Lori; Schoaf, Lori; Seward, William; Begolka, Wendy Smith; Stanton, Robert G; Svedman, Katherine J; Thomas, J Regan; Sykes, Jonathan M; Wargo, Carol; Weiss, Robert A

    2011-04-01

    : The American Society of Plastic Surgeons and the American Academy of Dermatology, with the support of other sister societies, conducted the Facial Soft-Tissue Fillers: Assessing the State of the Science conference in December of 2009. The American Society of Plastic Surgeons and the American Academy of Dermatology established a panel of leading experts in the field of soft-tissue fillers-from researchers to clinicians-and other stakeholders for the conference to examine and discuss issues of patient safety, efficacy, and effectiveness in relation to the approved and off-label use of soft-tissue fillers, and other factors, including the training and level of experience of individuals administering fillers. This report represents the systematic literature review that examines comprehensively the available evidence and gaps in the evidence related to soft-tissue fillers, to inform and support the work of the state-of-the-science conference panel. This evidence-based medicine review will serve as the foundation for future evidence-based medicine reports in this growing field.

  13. Ultrasound screening of periarticular soft tissue abnormality around metal-on-metal bearings.

    PubMed

    Nishii, Takashi; Sakai, Takashi; Takao, Masaki; Yoshikawa, Hideki; Sugano, Nobuhiko

    2012-06-01

    Although metal hypersensitivity or pseudotumors are concerns for metal-on-metal (MoM) bearings, detailed pathologies of patterns, severity, and incidence of periprosthetic soft tissue lesions are incompletely understood. We examined the potential of ultrasound for screening of periarticular soft tissue lesions around MoM bearings. Ultrasound examinations were conducted in 88 hips (79 patients) with MoM hip resurfacings or MoM total hip arthroplasties with a large femoral head. Four qualitative ultrasound patterns were shown, including normal pattern in 69 hips, joint-expansion pattern in 11 hips, cystic pattern in 5 hips, and mass pattern in 3 hips. Hips with the latter 3 abnormal patterns showed significantly higher frequency of clinical symptoms, without significant differences of sex, duration of implantation, head sizes, and cup abduction/anteversion angles, compared with hips with normal pattern. Ultrasound examination provides sensitive screening of soft tissue reactions around MoM bearings and may be useful in monitoring progression and defining treatment for periarticular soft tissue abnormalities. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. Soft tissue reconstruction of the oral cavity: a review of current options.

    PubMed

    Rigby, Matthew H; Taylor, S Mark

    2013-08-01

    This article provides an overview of the principles of soft tissue reconstruction of the oral cavity, and reviews the recent clinical outcomes for described options. For small defects of the oral cavity, healing by secondary intention and primary closure are both excellent options and may provide functionally superior results. In defects where a split-thickness skin graft is appropriate, acellular dermis may provide results that are at least as good at lower cost. Free flaps, particularly the radial forearm and the anterolateral thigh, have become the mainstays of oral cavity soft tissue reconstruction for larger defects. Recent clinical series suggest that relatively novel regional flaps provide a reasonable alternative to free flap reconstructions for moderate and some large soft tissue defects. Soft tissue reconstruction of the oral cavity is a complex task with significant functional implications. There are a large number of reconstructive options available. Systematic appraisal of the defect and options allows the reconstructive surgeon to optimize functional potential by choosing the most appropriate reconstructive option.

  15. Soft tissue-based surgical techniques for treatment of posterior shoulder instability.

    PubMed

    Castagna, Alessandro; Conti, Marco; Garofalo, Raffaele

    2017-01-01

    Posterior shoulder instability is a rare clinical condition that encompasses different degrees of severity including various possible pathologies involving the labrum, capsule, bony lesions, and even locked posterior dislocation. When focusing on soft tissue involvement, the diagnosis of posterior instability may be difficult to make because frequently patients report vague symptoms not associated with a clear history of traumatic shoulder dislocation. Pathological soft tissue conditions associated with posterior instability in most cases are related to posterior labral tear and/or posterior capsular detensioning/tear. The diagnosis can be facilitated by physical examination using specific clinical tests (i. e., jerk test, Kim test, and reinterpreted O'Brien test) together with appropriate imaging studies (i. e., magnetic resonance arthrography). Arthroscopy may help in a complete evaluation of the joint and allows for the treatment of soft tissue lesions in posterior instability. Caution is warranted in the case of concomitant posterior glenoid chondral defect as a potential cause of poor outcome after soft tissue repair in posterior instability.

  16. Long-term stability of soft tissue changes in anterior open bite adults treated with zygomatic miniplate-anchored maxillary posterior intrusion.

    PubMed

    Marzouk, Eiman S; Kassem, Hassan E

    2018-03-01

    To evaluate soft tissue changes and their long-term stability in skeletal anterior open bite adults treated by maxillary posterior teeth intrusion using zygomatic miniplates and premolar extractions. Lateral cephalograms of 26 patients were taken at pretreatment (T1), posttreatment (T2), 1 year posttreatment (T3), and 4 years posttreatment (T4). At the end of treatment, the soft tissue facial height and profile convexity were reduced. The lips increased in length and thickness, with backward movement of the upper lip and forward movement of the lower lip. The total relapse rate ranged from 20.2% to 31.1%. At 4 years posttreatment, 68.9% to 79.8% of the soft tissue treatment effects were stable. The changes in the first year posttreatment accounted for approximately 70% of the total relapse. Soft tissue changes following maxillary posterior teeth intrusion with zygomatic miniplates and premolar extractions appear to be stable 4 years after treatment.

  17. Arthroscopic debridement for soft tissue ankle impingement.

    PubMed

    Brennan, S A; Rahim, F; Dowling, J; Kearns, S R

    2012-06-01

    To assess the response to treatment in patients with soft tissue impingement of the ankle managed with arthroscopic debridement. Forty-one ankle arthroscopies were performed for soft tissue impingement between April 2007 and April 2009. There were 26 men and 15 women and the mean age was 30.1 years. Arthroscopy was performed on an average of 21 months after injury. The Visual-Analogue-Scale Foot and Ankle (VASFA) score and Meislin's criteria were used to assess the response to treatment. The mean pre-operative VASFA score was 44.5. This increased to 78.3 postoperatively (p < 0.0001). According to Meislin's criteria, there were 34 good or excellent results, five fair and two poor results. Pre-operative magnetic resonance imaging was useful in detecting tears of the anterior talofibular ligament and excluding osteochondral defects; however, synovitis and soft tissue impingement was under-reported. Arthroscopy is an effective method for the diagnoses and treatment of soft tissue impingement of the ankle joint. This condition is under-reported on MRI.

  18. Reconstruction of the pelvic floor and perineum with human acellular dermal matrix and thigh flaps following pelvic exenteration.

    PubMed

    Said, Hakim K; Bevers, Michael; Butler, Charles E

    2007-12-01

    Patients who undergo pelvic floor resection as treatment for recurrent cancer following radiation therapy have increased rates of complications, particularly if permanent prosthetic mesh is used for reconstruction. Human acellular dermal matrix (HADM), commonly used for reconstruction in other torso locations, is associated with lower rates of complications (including infection, adhesions and cutaneous exposure) than synthetic mesh. We describe an effective technique to reconstruct the pelvic floor and perineum with HADM and thigh-based flaps following pelvic exenteration and radical vulvectomy. A 75-year-old woman underwent radical resection of the pelvic floor and perineum to treat recurrent vulvar squamous cell carcinoma and osteoradionecrosis. The pelvic floor and perineal soft tissue defect were reconstructed with HADM (AlloDerm; LifeCell Corporation, Branchburg, NJ) and bilateral, thigh-based tissue flaps, respectively. Despite a large resection, previous irradiation therapy and bacterial contamination the wounds healed without complications. Reconstruction of pelvic floor defects using HADM is an option when wound conditions are unfavorable for the use of permanent prosthetic meshes.

  19. Use of a porcine collagen matrix as an alternative to autogenous tissue for grafting oral soft tissue defects.

    PubMed

    Herford, Alan S; Akin, Lee; Cicciu, Marco; Maiorana, Carlo; Boyne, Philip J

    2010-07-01

    Soft tissue grafting is often required to correct intraoral mucosal deficiencies. Autogenous grafts have disadvantages including an additional harvest site with its associated pain and morbidity and, sometimes, poor quality and limited amount of the graft. Porcine collagen matrices have the potential to be helpful for grafting of soft tissue defects. Thirty consecutive patients underwent intraoral grafting to re-create missing soft tissue. Defects ranged in size from 50 to 900 mm(2). Porcine collagen matrices were used to reconstruct missing tissue. Indications included preprosthetic (22), followed by tumor removal (5), trauma (2), and release of cheek ankylosis (1). The primary efficacy parameters evaluated were the degree of lateral and/or alveolar extension and the evaluation of re-epithelialization and shrinkage of the grafted area. Overall, the percentage of shrinkage of the graft was 14% (range, 5%-20%). The amount of soft tissue extension averaged 3.4 mm (range, 2-10 mm). The secondary efficacy parameters included hemostatic effect, pain evaluation, pain and discomfort, and clinical evaluation of the grafted site. All patients reported minimal pain and swelling associated with the grafted area. No infections were noted. This porcine collagen matrix provides a biocompatible surgical material as an alternative to an autogenous transplant, thus obviating the need to harvest soft tissue autogenous grafts from other areas of the oral cavity. Copyright 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Correlation between histological and ultrasonographic findings of soft tissue tumors: To verify the possibility of cell-like resolution in ultrasonography.

    PubMed

    Wu, Ching-Lan; Lai, Yi-Chen; Wang, Hsin-Kai; Chen, Paul Chih-Hsueh; Chiou, Hong-Jen

    2017-11-01

    The purpose of this study is to test the possibility of obtained cell-like resolution in soft tissue tumors on the basis of ultrasound echotexture. This is a prospective study consisting of 57 patients (29 females and 28 males, age range: 9-83 years, average age: 44.5 years) with palpable soft tissue mass, referred from the Departments of Orthopedics and Oncology for ultrasound (US)-guided biopsy. The study was approved by the institutional review board (IRB) of our hospital. Ultrasonographic images were recorded by still imaging in the biopsy tract in each biopsy session. Equipment included curvilinear and linear array probes. After biopsy, a radiologist and a pathologist correlated the US image and the observations regarding the histology of the tissue specimen in low-power (40 × magnification) and high-power (100-400 × magnification) fields. The histologic results included 22 benign and 35 malignant lesions. The echotexture of the soft tissue tumors correlated well with the cellular distribution and arrangement: the greater the number of cells and the more regular their arrangement as seen histologically, the greater is the hypoechogenicity on the ultrasound. The echogenicity of the soft tissue tumor also correlated well with the presence of fat cells, hemorrhage, cartilage, and osteoid tissue, all of which cause an increase in echogenicity. This study showed that the echotexture of soft tissue tumors can predict some details of cellular histology. Copyright © 2017. Published by Elsevier Taiwan LLC.

  1. Soft tissue response in orthognathic surgery patients treated by bimaxillary osteotomy: cephalometry compared with 2-D photogrammetry.

    PubMed

    Rustemeyer, Jan; Martin, Alice

    2013-03-01

    Since improvement of facial aesthetics after orthognathic surgery moves increasingly into the focus of patients, prediction of soft tissue response to hard tissue movement becomes essential for planning. The aim of this study was to assess the facial soft tissue response in skeletal class II and III patients undergoing orthognathic surgery and to compare the potentials of cephalometry and two-dimensional (2-D) photogrammetry for predicting soft tissue changes. Twenty-eight patients with class II relationship and 33 with class III underwent bimaxillary surgery. All subjects had available both a traced lateral cephalogram and a traced lateral photogram taken pre- and postsurgery in natural head position (median follow-up, 9.4 ± 0.6 months). Facial convexity and lower lip length were highly correlated with hard tissue movements cephalometrically in class III patients and 2-D photogrammetrically in both classes. In comparison, cephalometric correlations for class II patients were weak. Correlations of hard and soft tissue movements between pre- and postoperative corresponding landmarks in horizontal and vertical planes were significant for cephalometry and 2-D photogrammetry. No significant difference was found between cephalometry and 2-D photogrammetry with respect to soft to hard tissue movement ratios. This study revealed that cephalometry is still a feasible standard for evaluating and predicting outcomes in routine orthognathic surgery cases. Accuracy could be enhanced with 2-D photogrammetry, especially in class II patients.

  2. Facial Soft Tissue Trauma

    PubMed Central

    Kretlow, James D.; McKnight, Aisha J.; Izaddoost, Shayan A.

    2010-01-01

    Traumatic facial soft tissue injuries are commonly encountered in the emergency department by plastic surgeons and other providers. Although rarely life-threatening, the treatment of these injuries can be complex and may have significant impact on the patient's facial function and aesthetics. This article provides a review of the relevant literature related to this topic and describes the authors' approach to the evaluation and management of the patient with facial soft tissue injuries. PMID:22550459

  3. Complicated acute appendicitis presenting as a rapidly progressive soft tissue infection of the abdominal wall: a case report.

    PubMed

    Beerle, Corinne; Gelpke, Hans; Breitenstein, Stefan; Staerkle, Ralph F

    2016-12-01

    We report a case of a rare complication of acute appendicitis with perforation through the abdominal wall. The case points out that an intraabdominal origin should be considered in patients presenting with rapidly spreading soft tissue infections of the trunk. A 58-year-old European woman presented to our hospital with a 1-week history of severe abdominal pain accompanied by rapidly spreading erythema and emphysema of the lower abdomen. On admission, the patient was in septic shock with leukocytosis and elevation of C-reactive protein. Among other diagnoses, necrotizing fasciitis was suspected. Computed tomography showed a large soft tissue infection with air-fluid levels spreading through the lower abdominal wall. During the operation, we found a perforated appendicitis breaking through the fascia and causing a rapidly progressive soft tissue infection of the abdominal wall. Appendicitis was the origin of the soft tissue infection. The abdominal wall was only secondarily involved. Even though perforated appendicitis as an etiology of a rapidly progressive soft tissue infection of the abdominal wall is very rare, it should be considered in the differential diagnosis of abdominal wall cellulitis. The distinction between rapidly spreading subcutaneous infection with abscess formation and early onset of necrotizing fasciitis is often difficult and can be confirmed only by surgical intervention.

  4. Soft tissue waxup and mock-up as key factors in a treatment plan: case presentation.

    PubMed

    Viana, Pedro Couto; Correia, André; Neves, Manuel; Kovacs, Zsolt; Neugbauer, Rudiger

    2012-01-01

    Rehabilitation of edentulous spaces in esthetic areas is a challenge to the clinician due to the loss of soft tissues. In these clinical situations, it would be desirable to evaluate and predict the gingival architecture to recover in the oral rehabilitation. To fulfill this need, the diagnostic wax should anticipate the final rehabilitation with the integration of hard and soft tissue. Thus, it is essential to produce a diagnostic waxup that integrates these two components that are simultaneously seeking to recreate the harmony of white and pink esthetic. This diagnostic waxup will be the basis for the creation of the provisional prosthesis and a soft tissue mock-up. After placing the provisional prosthesis in the mouth, the soft tissue mock-up can be applied to assess its esthetic impact at facial and intraoral level. Dentist and patient should objectively assess the appearance of the final result. After approval of this rehabilitation concept, the virtual surgical planning can be performed and the surgical guide can be designed, allowing the treatment to take place. This protocol allows the development of a rigorous treatment plan based on the integration of teeth and gingiva component. The waxup and the soft tissue mock-up play a significant role, since they allow an earlier evaluation of the esthetic result, better prosthetic and surgical planning, and it allows us to anticipate the need for gingiva-colored ceramics use. The authors present a clinical case report of the importance of the wax-up and soft tissue mock-up in the treatment plan.

  5. The application of diode laser in the treatment of oral soft tissues lesions. A literature review.

    PubMed

    Ortega-Concepción, Daniel; Cano-Durán, Jorge A; Peña-Cardelles, Juan-Francisco; Paredes-Rodríguez, Víctor-Manuel; González-Serrano, José; López-Quiles, Juan

    2017-07-01

    Since its appearance in the dental area, the laser has become a treatment of choice in the removal of lesions in the oral soft tissues, due to the numerous advantages they offer, being one of the most used currently the diode laser. The aim of this review was to determine the efficacy and predictability of diode laser as a treatment of soft tissue injuries compared to other surgical methods. A literature review of articles published in PubMed/MEDLINE, Scopus and the Cochrane Library databases between 2007 and 2017 was performed. "Diode laser", "soft tissue", "oral cavity" and "oral surgery" were employed for the search strategy. Only articles published English or Spanish were selected. The diode laser is a minimally invasive technology that offers great advantages, superior to those of the conventional scalpel, such as reduction of bleeding, inflammation and the lower probability of scars. Its effectiveness is comparable to that of other types of lasers, in addition to being an option of lower cost and greater ease of use. Its application in the soft tissues has been evaluated, being a safe and effective method for the excision of lesions like fibromas, epulis fissuratum and the accomplishment of frenectomies. The diode laser can be used with very good results for the removal of lesions in soft tissues, being used in small exophytic lesions due to their easy application, adequate coagulation, no need to suture and the slightest inflammation and pain. Key words: Diode laser, soft tissues, oral cavity, oral surgery.

  6. The Pedicled Latissimus Dorsi Flap Provides Effective Coverage for Large and Complex Soft Tissue Injuries Around the Elbow.

    PubMed

    Hacquebord, Jacques H; Hanel, Douglas P; Friedrich, Jeffrey B

    2017-08-01

    The pedicled latissimus flap has been shown to provide effective coverage of wounds around the elbow with an average size of 100 to 147 cm 2 but with complication rates of 20% to 57%. We believe the pedicled latissimus dorsi flap is an effective and safe technique that provides reliable and durable coverage of considerably larger soft tissue defects around the elbow and proximal forearm. A retrospective review was performed including all patients from Harborview Medical Center between 1998 and 2012 who underwent coverage with pedicled latissimus dorsi flap for defects around the elbow. Demographic information, injury mechanism, soft tissue defect size, complications (minor vs major), and time to surgery were collected. The size of the soft tissue defect, complications, and successful soft tissue coverage were the primary outcome measures. A total of 18 patients were identified with variable mechanisms of injury. Average defect size around the elbow was 422 cm 2 . Three patients had partial necrosis of the distal most aspect of the flap, which was treated conservatively. One patient required a secondary fasciocutaneous flap, and another required conversion to a free latissimus flap secondary to venous congestion. Two were lost to follow-up after discharge from the hospital. In all, 88% (14 of 16) of the patients had documented (>3-month follow-up) successful soft tissue coverage with single-stage pedicled latissimus dorsi flap. The pedicled latissimus dorsi flap is a reliable option for large and complex soft tissue injuries around the elbow significantly larger than previous reports. However, coverage of the proximal forearm remains challenging.

  7. Assessment of image quality in soft tissue and bone visualization tasks for a dedicated extremity cone-beam CT system.

    PubMed

    Demehri, S; Muhit, A; Zbijewski, W; Stayman, J W; Yorkston, J; Packard, N; Senn, R; Yang, D; Foos, D; Thawait, G K; Fayad, L M; Chhabra, A; Carrino, J A; Siewerdsen, J H

    2015-06-01

    To assess visualization tasks using cone-beam CT (CBCT) compared to multi-detector CT (MDCT) for musculoskeletal extremity imaging. Ten cadaveric hands and ten knees were examined using a dedicated CBCT prototype and a clinical multi-detector CT using nominal protocols (80 kVp-108mAs for CBCT; 120 kVp- 300 mAs for MDCT). Soft tissue and bone visualization tasks were assessed by four radiologists using five-point satisfaction (for CBCT and MDCT individually) and five-point preference (side-by-side CBCT versus MDCT image quality comparison) rating tests. Ratings were analyzed using Kruskal-Wallis and Wilcoxon signed-rank tests, and observer agreement was assessed using the Kappa-statistic. Knee CBCT images were rated "excellent" or "good" (median scores 5 and 4) for "bone" and "soft tissue" visualization tasks. Hand CBCT images were rated "excellent" or "adequate" (median scores 5 and 3) for "bone" and "soft tissue" visualization tasks. Preference tests rated CBCT equivalent or superior to MDCT for bone visualization and favoured the MDCT for soft tissue visualization tasks. Intraobserver agreement for CBCT satisfaction tests was fair to almost perfect (κ ~ 0.26-0.92), and interobserver agreement was fair to moderate (κ ~ 0.27-0.54). CBCT provided excellent image quality for bone visualization and adequate image quality for soft tissue visualization tasks. • CBCT provided adequate image quality for diagnostic tasks in extremity imaging. • CBCT images were "excellent" for "bone" and "good/adequate" for "soft tissue" visualization tasks. • CBCT image quality was equivalent/superior to MDCT for bone visualization tasks.

  8. Principles of definitive soft tissue coverage with flaps.

    PubMed

    Levin, L Scott

    2008-01-01

    Despite the emergence of negative pressure wound therapy with reticulated open cell foam (NPWT/ROCF) as delivered by V.A.C.(R) Therapy (KCI, San Antonio, TX) for orthopaedic trauma, vascularized tissue transfer whether it be pedicle, free, or tissue transfer using the operating microscope or as an island, remains the mainstay of soft tissue reconstruction for orthopaedic traumatology. The critisism of microvascular procedures has been that they are lengthy, costly, and required technical expertise to perform. While technical skills are required, microsurgical care has evolved into a routine operation with high degrees of success in experienced hand. The problem that still remains is access to surgeons who are interested in soft tissue reconstruction and can perform definitive coverage with flaps. There is a need in the orthopaedic community to solve the problem of lack of flap surgeons and as a result, NPWT/ROCF has been touted as the answer to flap reconstruction. NPWT/ROCF is an important addition to soft tissue reconstruction but it serves as a bridge rather than definitive coverage in many hands. Just as wound technology is evolving with tissue substitutes, growth factors and NPWT/ROCF flaps technology continues to advance with new perforator flaps and local regional flaps, particularly the sural flap, coming on line as mainstays of soft tissue reconstruction.

  9. Imunohistological aspects of the tissue around dental implants

    NASA Astrophysics Data System (ADS)

    Nimigean, Victor; Nimigean, Vanda R.; Sǎlǎvǎstru, Dan I.; Moraru, Simona; BuÅ£incu, Lavinia; Ivaşcu, Roxana V.; Poll, Alexandru

    2016-03-01

    Objectives: study of soft and hard tissues around implants. Material and methods: For the immunohistochemical and histological study of the implant/soft tissue interface, we examined pieces of peri-implant mucosa harvested from 35 patients. The implant/bone interface was assessed using histologic and histomorphometric examination of hard tissues around unloaded, early loaded or delayed loaded dental implants with pre-established design, with a sandblasted and acid-etched surface, placed both in extraction sockets, or after bone healing following tooth removal. This study was performed on 9 common race dogs. Results: The histological study of the implant/soft tissue interface showed regenerative modifications and moderate chronic subepithelial inflammatory reactions. Immunohistochemical evaluation of the soft tissue biopsies revealed the presence of specific immunocompetent cells and proteins of the matrix metalloproteinase (MMP) expression. Bone-implants contacts were more obvious in the apical half of the implants and at the edges of the threads, than between them. A mature, lamelliform bone containing lacunae with osteocytes and lack of connective tissue were noticed around implants that were late placed and loaded. The new-formed bone was also abundant in the crestal zone, not only in the apical part of the implants. Conclusions: A thorough understanding of the microstructure of dental implant/soft and hard tissue interface will improve the longevity of osseointegrated implants.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nguyen, Thao D.; Grazier, John Mark; Boyce, Brad Lee

    Biological tissues are uniquely structured materials with technologically appealing properties. Soft tissues such as skin, are constructed from a composite of strong fibrils and fluid-like matrix components. This was the first coordinated experimental/modeling project at Sandia or in the open literature to consider the mechanics of micromechanically-based anisotropy and viscoelasticity of soft biological tissues. We have exploited and applied Sandia's expertise in experimentation and mechanics modeling to better elucidate the behavior of collagen fibril-reinforced soft tissues. The purpose of this project was to provide a detailed understanding of the deformation of ocular tissues, specifically the highly structured skin-like tissue inmore » the cornea. This discovery improved our knowledge of soft/complex materials testing and modeling. It also provided insight into the way that cornea tissue is bio-engineered such that under physiologically-relevant conditions it has a unique set of properties which enhance functionality. These results also provide insight into how non-physiologic loading conditions, such as corrective surgeries, may push the cornea outside of its natural design window, resulting in unexpected non-linear responses. Furthermore, this project created a clearer understanding of the mechanics of soft tissues that could lead to bio-inspired materials, such as highly supple and impact resistant body armor, and improve our design of human-machine interfaces, such as micro-electrical-mechanical (MEMS) based prosthetics.« less

  11. Mussel-inspired tough hydrogels with self-repairing and tissue adhesion

    NASA Astrophysics Data System (ADS)

    Gao, Zijian; Duan, Lijie; Yang, Yongqi; Hu, Wei; Gao, Guanghui

    2018-01-01

    The mussel-inspired polymeric hydrogels have been attractively explored owing to their self-repairing or adhesive property when the catechol groups of dopamine could chelate metal ions. However, it was a challenge for self-repairing hydrogels owning high mechanical properties. Herein, a synergistic strategy was proposed by combining catechol-Fe3+ complexes and hydrophobic association. The resulting hydrogels exhibited seamless self-repairing behavior, tissue adhesion and high mechanical property. Moreover, the pH-dependent stoichiometry of catechol-Fe3+ and temperature-sensitive hydrophobic association endue hydrogels with pH/thermo responsive characteristics. Subsequently, the self-repairing rate and mechanical property of hydrogels were investigated at different pH and temperature. This bio-inspired strategy would build an avenue for designing and constructing a new generation of self-repairing, tissue-adhesive and tough hydrogel.

  12. Breathing life into dinosaurs: tackling challenges of soft-tissue restoration and nasal airflow in extinct species.

    PubMed

    Bourke, Jason M; Porter, W M Ruger; Ridgely, Ryan C; Lyson, Tyler R; Schachner, Emma R; Bell, Phil R; Witmer, Lawrence M

    2014-11-01

    The nasal region plays a key role in sensory, thermal, and respiratory physiology, but exploring its evolution is hampered by a lack of preservation of soft-tissue structures in extinct vertebrates. As a test case, we investigated members of the "bony-headed" ornithischian dinosaur clade Pachycephalosauridae (particularly Stegoceras validum) because of their small body size (which mitigated allometric concerns) and their tendency to preserve nasal soft tissues within their hypermineralized skulls. Hypermineralization directly preserved portions of the olfactory turbinates along with an internal nasal ridge that we regard as potentially an osteological correlate for respiratory conchae. Fossil specimens were CT-scanned, and nasal cavities were segmented and restored. Soft-tissue reconstruction of the nasal capsule was functionally tested in a virtual environment using computational fluid dynamics by running air through multiple models differing in nasal soft-tissue conformation: a bony-bounded model (i.e., skull without soft tissue) and then models with soft tissues added, such as a paranasal septum, a scrolled concha, a branched concha, and a model combining the paranasal septum with a concha. Deviations in fluid flow in comparison to a phylogenetically constrained sample of extant diapsids were used as indicators of missing soft tissue. Models that restored aspects of airflow found in extant diapsids, such as appreciable airflow in the olfactory chamber, were judged as more likely. The model with a branched concha produced airflow patterns closest to those of extant diapsids. These results from both paleontological observation and airflow modeling indicate that S. validum and other pachycephalosaurids could have had both olfactory and respiratory conchae. Although respiratory conchae have been linked to endothermy, such conclusions require caution in that our re-evaluation of the reptilian nasal apparatus indicates that respiratory conchae may be more widespread than originally thought, and other functions, such as selective brain temperature regulation, could be important. © 2014 Wiley Periodicals, Inc.

  13. Bone-Patellar Tendon-Bone Versus Soft-Tissue Allograft for Anterior Cruciate Ligament Reconstruction: A Systematic Review.

    PubMed

    Joyce, Christopher D; Randall, Kyle L; Mariscalco, Michael W; Magnussen, Robert A; Flanigan, David C

    2016-02-01

    To describe the outcomes of bone-patellar tendon-bone (BPTB) and soft-tissue allografts in anterior cruciate ligament (ACL) reconstruction with respect to graft failure risk, physical examination findings, instrumented laxity, and patient-reported outcomes. A search of the PubMed, Scopus, CINAHL (Cumulative Index to Nursing and Allied Health Literature) Complete, Cochrane Collaboration, and SPORTDiscus databases was performed. English-language studies with outcome data on primary ACL reconstruction with nonirradiated BPTB and soft-tissue allografts were identified. Outcome data included failure risk, physical examination findings, instrumented laxity measurements, and patient-reported outcome scores. Seventeen studies met the inclusion criteria. Of these studies, 11 reported on BPTB allografts exclusively, 5 reported on soft-tissue allografts exclusively, and 1 compared both types. The comparative study showed no difference in failure risk, Lachman grade, pivot-shift grade, instrumented laxity, or overall International Knee Documentation Committee score between the 2 allograft types. Data from all studies yielded a failure risk of 10.3% (95% confidence interval [CI], 4.5% to 18.1%) in the soft-tissue group and 15.2% (95% CI, 11.3% to 19.6%) in the BPTB group. The risk of a Lachman grade greater than 5 mm was 6.4% (95% CI, 1.7% to 13.7%) in the soft-tissue group and 8.6% (95% CI, 6.3% to 11.2%) in the BPTB group. The risk of a grade 2 or 3 pivot shift was 1.4% (95% CI, 0.3% to 3.3%) in the soft-tissue group and 4.1% (95% CI, 1.9% to 7.2%) in the BPTB group. One comparative study showed no difference in results after ACL reconstruction with nonirradiated BPTB and soft-tissue allografts. Inclusion of case series in the analysis showed qualitatively similar outcomes with the 2 graft types. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  14. Distal chevron osteotomy with lateral soft tissue release for moderate to severe hallux valgus decided using intraoperative varus stress radiographs.

    PubMed

    Kim, Hyong-Nyun; Park, Yoo-Jung; Kim, Gab-Lae; Park, Yong-Wook

    2013-01-01

    The purpose of the present study was to investigate the outcomes of distal chevron osteotomy with lateral soft tissue release for moderate to severe hallux valgus. The patients were selected using criteria that included the degree of lateral soft tissue contracture and metatarsocuneiform joint flexibility. The contracture and flexibility were determined from intraoperative varus stress radiographs. From April 2007 to May 2009, 56 feet in 51 consecutive patients with moderate to severe hallux valgus had undergone distal chevron osteotomy with lateral soft tissue release. This was done when the lateral soft tissue contracture was not so severe that passive correction of the hallux valgus deformity was not possible and when the metatarsocuneiform joint was flexible enough to permit additional correction of the first intermetatarsal angle after lateral soft tissue release. The mean patient age was 45.2 (range 23 to 54) years, and the duration of follow-up was 27.5 (range 24 to 46) months. The mean hallux abductus angle decreased from 33.5° ± 3.1° to 11.6° ± 3.3°, and the first intermetatarsal angle decreased from 16.4° ± 2.7° to 9.7° ± 2.1°. The mean American Orthopaedic Foot and Ankle Society hallux-interphalangeal scores increased from 66.6° ± 10.7° to 92.6° ± 9.4° points, and 46 of the 51 patients (90%) were either very satisfied or satisfied with the outcome. No recurrence of deformity or osteonecrosis of the metatarsal head occurred. When lateral soft tissue contracture is not severe and when the metatarsocuneiform joint is flexible enough, distal chevron osteotomy with lateral soft tissue release can be a useful and effective choice for moderate to severe hallux valgus deformity. Copyright © 2013 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Socket Preservation using Enzyme-treated Equine Bone Granules and an Equine Collagen Matrix: A Case Report with Histological and Histomorphometrical Assessment.

    PubMed

    Leonida, Alessandro; Todeschini, Giovanni; Lomartire, Giovanni; Cinci, Lorenzo; Pieri, Laura

    2016-11-01

    To histologically assess the effectiveness of a socket-preservation technique using enzyme-treated equine bone granules as a bone-graft material in combination with an equine collagen matrix as a scaffold for soft-tissue regeneration. Enzyme-treated equine bone granules and equine collagen matrix recently have been developed to help overcome alveolar bone deficiencies that develop in the wake of edentulism. The patient had one mandibular molar extracted and the socket grafted with equine bone granules. The graft was covered with the equine collagen matrix, placed in a double layer. No flap was prepared, and the gingival margins were stabilized with a single stitch, leaving the matrix partially exposed and the site to heal by secondary intention. The adjacent molar was extracted 1 month later, and that socket was left to heal by secondary intention without any further treatment. Three months after each surgery, an implant was placed and a biopsy was collected. The two biopsies underwent histological processing and qualitative evaluation. Histomorphometric analysis was also performed to calculate the percentage of newly formed bone (NFB) in the two cores. Healing at both sites was uneventful, and no inflammation or other adverse reactions were observed in the samples. Soft-tissue healing by secondary intention appeared to occur faster at the grafted site. The corresponding core showed a marked separation between soft and hard tissue that was not observed in the core from the nongrafted site, where soft-tissue hypertrophy could be observed. Newly formed bone at the grafted and nongrafted sites was not significantly different (27.2 ± 7.1 and 29.4 ± 6.2% respectively, p = 0.45). The surgical technique employed in this case appeared to facilitate postextraction soft-tissue healing by second intention and simplify soft-tissue management. Using a collagen-based matrix to cover a postextraction grafted site may facilitate second intention soft-tissue healing and proper soft-tissue growth.

  16. Adhesion

    MedlinePlus

    ... Supplements Videos & Tools Español You Are Here: Home → Medical Encyclopedia → Adhesion URL of this page: //medlineplus.gov/ency/article/001493.htm Adhesion To use the sharing features on this page, please enable JavaScript. Adhesions are bands of scar-like tissue that form between two ...

  17. Tissue organization by cadherin adhesion molecules: dynamic molecular and cellular mechanisms of morphogenetic regulation

    PubMed Central

    Niessen, Carien M.; Leckband, Deborah; Yap, Alpha S.

    2013-01-01

    This review addresses the cellular and molecular mechanisms of cadherin-based tissue morphogenesis. Tissue physiology is profoundly influenced by the distinctive organizations of cells in organs and tissues. In metazoa, adhesion receptors of the classical cadherin family play important roles in establishing and maintaining such tissue organization. Indeed, it is apparent that cadherins participate in a range of morphogenetic events that range from support of tissue integrity to dynamic cellular rearrangements. A comprehensive understanding of cadherin-based morphogenesis must then define the molecular and cellular mechanisms that support these distinct cadherin biologies. Here we focus on four key mechanistic elements: the molecular basis for adhesion through cadherin ectodomains; the regulation of cadherin expression at the cell surface; cooperation between cadherins and the actin cytoskeleton; and regulation by cell signaling. We discuss current progress and outline issues for further research in these fields. PMID:21527735

  18. Tissue cohesion and the mechanics of cell rearrangement.

    PubMed

    David, Robert; Luu, Olivia; Damm, Erich W; Wen, Jason W H; Nagel, Martina; Winklbauer, Rudolf

    2014-10-01

    Morphogenetic processes often involve the rapid rearrangement of cells held together by mutual adhesion. The dynamic nature of this adhesion endows tissues with liquid-like properties, such that large-scale shape changes appear as tissue flows. Generally, the resistance to flow (tissue viscosity) is expected to depend on the cohesion of a tissue (how strongly its cells adhere to each other), but the exact relationship between these parameters is not known. Here, we analyse the link between cohesion and viscosity to uncover basic mechanical principles of cell rearrangement. We show that for vertebrate and invertebrate tissues, viscosity varies in proportion to cohesion over a 200-fold range of values. We demonstrate that this proportionality is predicted by a cell-based model of tissue viscosity. To do so, we analyse cell adhesion in Xenopus embryonic tissues and determine a number of parameters, including tissue surface tension (as a measure of cohesion), cell contact fluctuation and cortical tension. In the tissues studied, the ratio of surface tension to viscosity, which has the dimension of a velocity, is 1.8 µm/min. This characteristic velocity reflects the rate of cell-cell boundary contraction during rearrangement, and sets a limit to rearrangement rates. Moreover, we propose that, in these tissues, cell movement is maximally efficient. Our approach to cell rearrangement mechanics links adhesion to the resistance of a tissue to plastic deformation, identifies the characteristic velocity of the process, and provides a basis for the comparison of tissues with mechanical properties that may vary by orders of magnitude. © 2014. Published by The Company of Biologists Ltd.

  19. Quantitative measurement of adhesion of ink on plastic films with a Nano Indenter and a Scanning Probe Microscope

    NASA Astrophysics Data System (ADS)

    Shen, Weidian

    2005-03-01

    Plastic film packaging is widely used these days, especially in the convenience food industry due to its flexibility, boilability, and microwavability. Almost every package is printed with ink. The adhesion of ink on plastic films merits increasing attention to ensure quality packaging. However, inks and plastic films are polymeric materials with complicated molecular structures. The thickness of the jelly-like ink is only 500nm or less, and the thickness of the soft and flexible film is no more than 50μm, which make the quantitative measurement of their adhesion very challenging. Up to now, no scientific quantitative measurement method for the adhesion of ink on plastic films has been documented. We have tried a technique, in which a Nano-Indenter and a Scanning Probe Microscope were used to evaluate the adhesion strength of ink deposited on plastic films, quantitatively, as well as examine the configurations of adhesion failure. It was helpful in better understanding the adhesion mechanism, thus giving direction as to how to improve the adhesion.

  20. The role of glycosaminoglycans in tissue adhesion during energy-based vessel sealing

    NASA Astrophysics Data System (ADS)

    Kramer, Eric A.; Anderson, Nicholas S.; Taylor, Kenneth D.; Ferguson, Virginia L.; Rentschler, Mark E.

    2015-03-01

    Energy-based vessel sealing remains a common alternative to traditional mechanical ligation procedures, despite considerable uncertainty as to the origin and stability of vascular adhesion forces. Evidence of conformal changes in Collagen IA has fostered support of denatured collagen as the origin of tissue adhesion; experimental observation suggests that while pure collagen fails to adhere, remaining vascular constituents play a critical adhesive role. This study initiates a constitutive model of adhesion forces in thermal fusion by determining the effects of glycosaminoglycan (GAG) content on the bursting pressure of thermally sealed vessels. GAG content of porcine splenic arteries was progressively altered via pre-fusion treatment in Chondroitinase ABC (ChABC) for 0-5h at 1U/mL (n=10/gp.), followed by fusion with the ConMed ALTRUS® thermal fusion device and subsequent strength testing. Sulfated GAG (sGAG) concentrations as quantified by the Dimethylmethylene Blue (DMMB) assay were reduced in ChABC-treated vessels (5h) by 73.8 +/- 4.2 % as compared with untreated tissue. Bursting pressures of ChABC-treated vessels (5h) were significantly greater than those of control vessels (800.33 +/- 54.34 mmHg and 438.40 +/- 51.81 mmHg respectively, p=2.0e-04). Histology enabled qualitative visualization of the treated arterial cross-section and of the bonding interface. The negative correlation between GAG content and arterial seal strengths suggests that by resisting water transport, arterial GAG presence may inhibit adhesive interactions between adjacent cellular tissue layers during energy-based vessel sealing. By elucidating the components which facilitate or inhibit adhesion in thermal vessel sealing, this study provides an important step towards understanding the chemistry underlying fusion and evaluating its potential for expansion to avascular tissues.

Top