Soft-Tissue Grafting Techniques Associated With Immediate Implant Placement.
Bishara, Mark; Kurtzman, Gregori M; Khan, Waji; Choukroun, Joseph; Miron, Richard J
2018-02-01
Immediate implant placement often presents challenges in terms of predictably obtaining soft-tissue coverage over the implant site. While delayed implant placement offers the ability for soft tissues to grow and invade the extraction socket making their attachment around implants more predictable, immediate implant placement poses a significant risk of bacterial invasion towards the implant surface as a result of insignificant soft-tissue volume. Soft-tissue grafting techniques have often been proposed for use during immediate implant placement to augment soft-tissue deficiencies, including the use of either palatal connective tissue grafts (CTGs) or collagen-derived scaffolds. However, both of these approaches have significant drawbacks in that CTGs are harvested with high patient morbidity and collagen scaffolds remain avascular and acelluar posing a risk of infection/implant contamination. More recently, platelet-rich fibrin (PRF) has been proposed as an economical and biological means to speed soft-tissue wound healing. In combination with immediate implant placement, PRF offers an easily procurable low-cost regenerative modality that offers an efficient way to improve soft-tissue attachment around implants. Furthermore, the supra-physiological concentration of defense-fighting leukocytes in PRF, combined with a dense fibrin meshwork, is known to prevent early bacterial contamination of implant surfaces, and the biological concentrations of autologous growth factors in PRF is known to increase tissue regeneration. This article discusses soft-tissue grafting techniques associated with immediate implant placement, presents several cases demonstrating the use of PRF in routine immediate implant placement, and further discusses the biological and economic advantages of PRF for the management of soft-tissue grafting during immediate implant placement.
Poskevicius, Lukas; Sidlauskas, Antanas; Galindo-Moreno, Pablo; Juodzbalys, Gintaras
2017-01-01
To systematically review changes in mucosal soft tissue thickness and keratinised mucosa width after soft tissue grafting around dental implants. An electronic literature search was conducted of the MEDLINE database published between 2009 and 2014. Sequential screenings at the title, abstract, and full-text levels were performed. Clinical human studies in the English language that had reported changes in soft tissue thickness or keratinised mucosa width after soft tissue grafting at implant placement or around a present implant at 6-month follow-up or longer were included. The search resulted in fourteen articles meeting the inclusion criteria: Six of them reported connective tissue grafting around present dental implants, compared to eight at the time of implant placement. Better long-term soft tissue thickness outcomes were reported for soft tissue augmentation around dental implants (0.8-1.4 mm), compared with augmentation at implant placement (-0.25-1.43 mm). Both techniques were effective in increasing keratinised tissue width: at implant placement (2.5 mm) or around present dental implants (2.33-2.57 mm). The present systematic review discovered that connective tissue grafts enhanced keratinised mucosa width and soft tissue thickness for an observation period of up to 48 months. However, some shrinkage may occur, resulting in decreases in soft tissue, mostly for the first three months. Further investigations using accurate evaluation methods need to be done to evaluate the appropriate time for grafting. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Kaminaka, Akihiro; Nakano, Tamaki; Ono, Shinji; Kato, Tokinori; Yatani, Hirofumi
2015-10-01
This study evaluated changes in the horizontal and vertical dimensions of the buccal alveolar bone and soft tissue over a 1-year period following implant prosthesis. Thirty-three participants with no history of guided bone regeneration or soft tissue augmentation underwent dental implant placement with different types of connections. The dimensions of the buccal alveolar bone and soft tissue were evaluated immediately and at 1 year after prosthesis from reconstructions of cross-sectional cone-beam computed tomography images. The vertical and horizontal loss of buccal bone and soft tissue around implants with conical connections were lower than around those with external or internal connections. Statistically significant negative correlations were observed between initial horizontal bone thickness and changes in vertical bone and soft tissue height (p < .05), and between initial horizontal soft tissue thickness and the change in vertical soft tissue height (p < .05). Implants with a conical connection preserve peri-implant alveolar bone and soft tissue more effectively than other connection types. Furthermore, the initial buccal alveolar bone and soft tissue thickness around the implant platform may influence their vertical dimensional changes at 1 year after implant prosthesis. © 2014 Wiley Periodicals, Inc.
Health, Maintenance, and Recovery of Soft Tissues around Implants.
Wang, Yulan; Zhang, Yufeng; Miron, Richard J
2016-06-01
The health of peri-implant soft tissues is one of the most important aspects of osseointegration necessary for the long-term survival of dental implants. To review the process of soft tissue healing around osseointegrated implants and discuss the maintenance requirements as well as the possible short-comings of peri-implant soft tissue integration. Literature search on the process involved in osseointegration, soft tissue healing and currently available treatment modalities was performed and a brief description of each process was provided. The peri-implant interface has been shown to be less effective than natural teeth in resisting bacterial invasion because gingival fiber alignment and reduced vascular supply make it more vulnerable to subsequent peri-implant disease and future bone loss around implants. And we summarized common procedures which have been shown to be effective in preventing peri-implantitis disease progression as well as clinical techniques utilized to regenerate soft tissues with bone loss in advanced cases of peri-implantitis. Due to the difference between peri-implant interface and natural teeth, clinicians and patients should pay more attention in the maintenance and recovery of soft tissues around implants. © 2015 Wiley Periodicals, Inc.
Mechanical verification of soft-tissue attachment on bioactive glasses and titanium implants.
Zhao, Desheng; Moritz, Niko; Vedel, Erik; Hupa, Leena; Aro, Hannu T
2008-07-01
Soft-tissue attachment is a desired feature of many clinical biomaterials. The aim of the current study was to design a suitable experimental method for tensile testing of implant incorporation with soft-tissues. Conical implants were made of three compositions of bioactive glass (SiO(2)-P(2)O(5)-B(2)O(3)-Na(2)O-K(2)O-CaO-MgO) or titanium fiber mesh (porosity 84.7%). The implants were surgically inserted into the dorsal subcutaneous soft-tissue or back muscles in the rat. Soft-tissue attachment was evaluated by pull-out testing using a custom-made jig 8 weeks after implantation. Titanium fiber mesh implants had developed a relatively high pull-out force in subcutaneous tissue (12.33+/-5.29 N, mean+/-SD) and also measurable attachment with muscle tissue (2.46+/-1.33 N). The bioactive glass implants failed to show mechanically relevant soft-tissue bonding. The experimental set-up of mechanical testing seems to be feasible for verification studies of soft-tissue attachment. The inexpensive small animal model is beneficial for large-scale in vivo screening of new biomaterials.
Reddy, Aileni Amarender; Kumar, P. Anoop; Sailaja, Sistla; Chakravarthy, Yshs
2015-01-01
Soft tissue deficiencies and defects around dental implants have been observed frequently. Soft-tissue defects after implant procedures originate from the process of modelling of periimplant mucosa and often cause aesthetic disharmony, food debris accumulation and soft tissue shrinkage. Periimplant mucogingival surgery focuses on creating an optimum band of keratinized tissue resulting in soft tissue architecture similar to the gingiva around natural teeth. A 23-year-old male reported to the Department of Periodontology with a complaint of gum soreness, foul smell and food accumulation at a site where a 3.75 x 11.5mm implant was placed previously. On clinical examination, fenestration of tissue above the cover screw was observed and there appeared to be a keratinized tissue of 1mm surrounding the implant. The case was managed by use of a rotated double-pedicle flap during second-stage implant surgery to correct the soft-tissue fenestration defect and to obtain a keratinized periimplant soft tissue. A periosteal bed was prepared by giving a horizontal incision at the mucogingival junction to a depth of 4 mm. Two split-thickness keratinized pedicles were dissected from the mesial and distal interproximal tissues near the implant. After rotation, both the pedicles were sutured to each other mid-buccally and the pedicles were rigidly immobilized with sutures. At 1 month, there was a 3mm band of stable and firm keratinized tissue over the underlying tissues. The procedure resulted in an aesthetic improvement due to enhanced soft tissue architecture and optimum integration between the peri-implant soft tissue and the final prosthesis. PMID:26816998
Soft tissue sealing around dental implants based on histological interpretation.
Atsuta, Ikiru; Ayukawa, Yasunori; Kondo, Ryosuke; Oshiro, Wakana; Matsuura, Yuri; Furuhashi, Akihiro; Tsukiyama, Yoshihiro; Koyano, Kiyoshi
2016-01-01
The aim of this study was to provide an overview on the biology and soft tissue sealing around dental implants and teeth. This is a narrative review performed through scientific articles published between 1977 and 2014, indexed in MEDLINE and PubMed databases. The study selected articles that focused on epithelial sealing around dental implant or teeth with cell biology and histology of soft tissue. Implant therapy has been widely applied in dental rehabilitation for many years, with predictable long-term results. The longevity and functionality of dental implants is dependent on both osseointegration around the implant body and the establishment of a soft tissue barrier that protects the underlying hard tissue structures and the implant itself. The health and stability of the peri-implant mucosa also affects the esthetics of the implant. The healing and maintenance of the epithelial and connective tissues around implants are increasingly recognized as being fundamental to implant success. However, there has been little research into the function or formation of the soft tissue seal around dental implants, and the roles of this unique mucosal interface remain unclear. This narrative review explores the extent of the current knowledge of soft tissue barriers around implants from both a basic and clinical perspective, and aims to consolidate this knowledge and highlight the most pertinent questions relating to this area of research. Copyright © 2015 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
Imunohistological aspects of the tissue around dental implants
NASA Astrophysics Data System (ADS)
Nimigean, Victor; Nimigean, Vanda R.; Sǎlǎvǎstru, Dan I.; Moraru, Simona; BuÅ£incu, Lavinia; Ivaşcu, Roxana V.; Poll, Alexandru
2016-03-01
Objectives: study of soft and hard tissues around implants. Material and methods: For the immunohistochemical and histological study of the implant/soft tissue interface, we examined pieces of peri-implant mucosa harvested from 35 patients. The implant/bone interface was assessed using histologic and histomorphometric examination of hard tissues around unloaded, early loaded or delayed loaded dental implants with pre-established design, with a sandblasted and acid-etched surface, placed both in extraction sockets, or after bone healing following tooth removal. This study was performed on 9 common race dogs. Results: The histological study of the implant/soft tissue interface showed regenerative modifications and moderate chronic subepithelial inflammatory reactions. Immunohistochemical evaluation of the soft tissue biopsies revealed the presence of specific immunocompetent cells and proteins of the matrix metalloproteinase (MMP) expression. Bone-implants contacts were more obvious in the apical half of the implants and at the edges of the threads, than between them. A mature, lamelliform bone containing lacunae with osteocytes and lack of connective tissue were noticed around implants that were late placed and loaded. The new-formed bone was also abundant in the crestal zone, not only in the apical part of the implants. Conclusions: A thorough understanding of the microstructure of dental implant/soft and hard tissue interface will improve the longevity of osseointegrated implants.
Soft tissue grafting to improve implant esthetics
Kassab, Moawia M
2010-01-01
Dental implants are becoming the treatment of choice to replace missing teeth, especially if the adjacent teeth are free of restorations. When minimal bone width is present, implant placement becomes a challenge and often resulting in recession and dehiscence around the implant that leads to subsequent gingival recession. To correct such defect, the author turned to soft tissue autografting and allografting to correct a buccal dehiscence around tooth #24 after a malpositioned implant placed by a different surgeon. A 25-year-old woman presented with the chief complaint of gingival recession and exposure of implant threads around tooth #24. The patient received three soft tissue grafting procedures to augment the gingival tissue. The first surgery included a connective tissue graft to increase the width of the keratinized gingival tissue. The second surgery included the use of autografting (connective tissue graft) to coronally position the soft tissue and achieve implant coverage. The third and final surgery included the use of allografting material Alloderm to increase and mask the implant from showing through the gingiva. Healing period was uneventful for the patient. After three surgical procedures, it appears that soft tissue grafting has increased the width and height of the gingiva surrounding the implant. The accomplished thickness of gingival tissue appeared to mask the showing of implant threads through the gingival tissue and allowed for achieving the desired esthetic that the patient desired. The aim of the study is to present a clinical case with soft tissue grafting procedures. PMID:23662087
Giannobile, William V; Jung, Ronald E; Schwarz, Frank
2018-03-01
The goal of Working Group 1 at the 2nd Consensus Meeting of the Osteology Foundation was to comprehensively assess the effects of soft tissue augmentation procedures on peri-implant health or disease. A systematic review and meta-analysis on the effects of soft tissue augmentation procedures included a total of 10 studies (mucosal thickness: n = 6; keratinized tissue: n = 4). Consensus statements, clinical recommendations, and implications for future research were based on structured group discussions and a plenary session approval. Soft tissue grafting to increase the width of keratinized tissue around implants was associated with greater reductions in gingival and plaque indices when compared to non-augmented sites. Statistically significant differences were noted for final marginal bone levels in favor of an apically positioned flap plus autogenous graft vs. all standard-of-care control treatments investigated. Soft tissue grafting (i.e., autogenous connective tissue) to increase the mucosal thickness around implants in the aesthetic zone was associated with significantly less marginal bone loss over time, but no significant changes in bleeding on probing, probing depths, or plaque scores when compared to sites without grafting. The limited evidence available supports the use of soft tissue augmentation procedures to promote peri-implant health. © 2018 The Authors. Clinical Oral Implants Research Published by John Wiley & Sons Ltd.
Baltacioğlu, Esra; Korkmaz, Yavuz Tolga; Korkmaz, Fatih Mehmet; Aydin, Güven; Sukuroglu, Erkan
2017-01-01
This report presents the clinical results of peri-implant plastic surgical approaches for hard and soft tissues before and during the implant placement in a patient with vertical ridge deformation and a shallow vestibule sulcus, and the subsequently performed prosthetic rehabilitation. The surgical approaches used in this case reduced the crown-height space and crown-to-implant ratio and ensured that the implants were placed in their ideal positions, and peri-implant tissue health was maintained. In conclusion, developments in the peri-implant plastic surgery enable the successful augmentation of hard and soft tissue defects and provide the implant-supported fixed prosthetic rehabilitation. PMID:29386805
Soft Tissue Grafting Around Teeth and Implants.
Deeb, George R; Deeb, Janina Golob
2015-08-01
The presence of healthy attached tissue at the tooth and implant soft tissue interface correlates with long-term success and stability in function and esthetics. There are several soft tissue grafting procedures that increase the volume of keratinized tissue and provide coverage on both teeth and implants. Many of these techniques can be used in conjunction with implant placement, or after placement as a means of salvage. This article describes the techniques for augmentation of keratinized tissue as well as root and implant coverage. These tools should be in the armamentarium of oral and maxillofacial surgeons providing implant services. Copyright © 2015 Elsevier Inc. All rights reserved.
Hämmerle, Christoph H F; Giannobile, William V
2014-04-01
The scope of this consensus was to review the biological processes of soft tissue wound healing in the oral cavity and to histologically evaluate soft tissue healing in clinical and pre-clinical models. To review the current knowledge regarding the biological processes of soft tissue wound healing at teeth, implants and on the edentulous ridge. Furthermore, to review soft tissue wound healing at these sites, when using barrier membranes, growth and differentiation factors and soft tissue substitutes. Searches of the literature with respect to recessions at teeth and soft tissue deficiencies at implants, augmentation of the area of keratinized tissue and soft tissue volume were conducted. The available evidence was collected, categorized and summarized. Oral mucosal and skin wound healing follow a similar pattern of the four phases of haemostasis, inflammation, proliferation and maturation/matrix remodelling. The soft connective tissue determines the characteristics of the overlaying oral epithelium. Within 7-14 days, epithelial healing of surgical wounds at teeth is completed. Soft tissue healing following surgery at implants requires 6-8 weeks for maturation. The resulting tissue resembles scar tissue. Well-designed pre-clinical studies providing histological data have been reported describing soft tissue wound healing, when using barrier membranes, growth and differentiation factors and soft tissue substitutes. Few controlled clinical studies with low numbers of patients are available for some of the treatments reviewed at teeth. Whereas, histological new attachment has been demonstrated in pre-clinical studies resulting from some of the treatments reviewed, human histological data commonly report a lack of new attachment but rather long junctional epithelial attachment and connective tissue adhesion. Regarding soft tissue healing at implants human data are very scarce. Oral soft tissue healing at teeth, implants and the edentulous ridge follows the same phases as skin wound healing. Histological studies in humans have not reported new attachment formation at teeth for the indications studied. Human histological data of soft tissue wound healing at implants are limited. The use of barriers membranes, growth and differentiation factors and soft tissue substitutes for the treatment of localized gingival/mucosal recessions, insufficient amount of keratinized tissue and insufficient soft tissue volume is at a developing stage. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Cosgarea, Raluca; Gasparik, Cristina; Dudea, Diana; Culic, Bogdan; Dannewitz, Bettina; Sculean, Anton
2015-05-01
To objectively determine the difference in colour between the peri-implant soft tissue at titanium and zirconia abutments. Eleven patients, each with two contralaterally inserted osteointegrated dental implants, were included in this study. The implants were restored either with titanium abutments and porcelain-fused-to-metal crowns, or with zirconia abutments and ceramic crowns. Prior and after crown cementation, multi-spectral images of the peri-implant soft tissues and the gingiva of the neighbouring teeth were taken with a colorimeter. The colour parameters L*, a*, b*, c* and the colour differences ΔE were calculated. Descriptive statistics, including non-parametric tests and correlation coefficients, were used for statistical analyses of the data. Compared to the gingiva of the neighbouring teeth, the peri-implant soft tissue around titanium and zirconia (test group), showed distinguishable ΔE both before and after crown cementation. Colour differences around titanium were statistically significant different (P = 0.01) only at 1 mm prior to crown cementation compared to zirconia. Compared to the gingiva of the neighbouring teeth, statistically significant (P < 0.01) differences were found for all colour parameter, either before or after crown cementation for both abutments; more significant differences were registered for titanium abutments. Tissue thickness correlated positively with c*-values for titanium at 1 mm and 2 mm from the gingival margin. Within their limits, the present data indicate that: (i) The peri-implant soft tissue around titanium and zirconia showed colour differences when compared to the soft tissue around natural teeth, and (ii) the peri-implant soft tissue around zirconia demonstrated a better colour match to the soft tissue at natural teeth than titanium. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Lops, Diego; Stellini, Edoardo; Sbricoli, Luca; Cea, Niccolò; Romeo, Eugenio; Bressan, Eriberto
2017-10-01
The aim of the present clinical trial was to analyze, through spectrophotometric digital technology, the influence of the abutment material on the color of the peri-implant soft tissue in patients with thin gingival biotype. Thirty-seven patients received an endosseous dental implant in the anterior maxilla. At time of each definitive prosthesis delivery, an all-ceramic crown has been tried on gold, titanium and zirconia abutment. Peri-implant soft-tissue color has been measured through a spectrophotometer after the insertion of each single abutment. Also facial peri-implant soft-tissue thickness was measured at the level of the implant neck through a caliper. A specific software has been utilized to identify a standardized tissue area and to collect the data before the statistical analysis in Lab* color space. ΔE parameters of the selected abutments were tested for correlation with mucosal thickness. Pearson correlation test was used. Only 15 patients met the study inclusion criteria on peri-implant soft-tissue thickness. Peri-implant soft-tissue color was different from that around natural teeth, no matter which type of restorative material was selected. Measurements regarding all the abutments were above the critical threshold of ΔE 8.74 for intraoral color distinction by the naked eye. The ΔE mean values of gold and zirconium abutments were similar (11.43 and 11.37, respectively) and significantly lower (P = 0.03 and P = 0.04, respectively) than the titanium abutment (13.55). In patients with a facial soft-tissue thickness ≤2 mm, the ΔE mean value of gold and zirconia abutments was significantly lower than that of titanium abutments (P = 0.03 and P = 0.04, respectively) and much more close to the reference threshold of 8.74. For peri-implant soft tissue of ≤2 mm, gold or zirconia abutments could be selected in anterior areas treatment. Moreover, the thickness of the peri-implant soft tissue seemed to be a crucial factor in the abutment impact on the color of soft tissues with a thickness of ≤2 mm. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Photoactivated Composite Biomaterial for Soft Tissue Restoration in Rodents and in Humans
Nahas, Zayna; Reid, Branden; Coburn, Jeannine M.; Axelman, Joyce; Chae, Jemin J.; Guo, Qiongyu; Trow, Robert; Thomas, Andrew; Hou, Zhipeng; Lichtsteiner, Serge; Sutton, Damon; Matheson, Christine; Walker, Patricia; David, Nathaniel; Mori, Susumu; Taube, Janis M.; Elisseeff, Jennifer H.
2015-01-01
Soft tissue reconstruction often requires multiple surgical procedures that can result in scars and disfiguration. Facial soft tissue reconstruction represents a clinical challenge because even subtle deformities can severely affect an individual’s social and psychological function. We therefore developed a biosynthetic soft tissue replacement composed of poly(ethylene glycol) (PEG) and hyaluronic acid (HA) that can be injected and photocrosslinked in situ with transdermal light exposure. Modulating the ratio of synthetic to biological polymer allowed us to tune implant elasticity and volume persistence. In a small-animal model, implanted photocrosslinked PEG-HA showed a dose-dependent relationship between increasing PEG concentration and enhanced implant volume persistence. In direct comparison with commercial HA injections, the PEG-HA implants maintained significantly greater average volumes and heights. Reversibility of the implant volume was achieved with hyaluronidase injection. Pilot clinical testing in human patients confirmed the feasibility of the transdermal photocrosslinking approach for implantation in abdomen soft tissue, although an inflammatory response was observed surrounding some of the materials. PMID:21795587
Huber, Samuel; Zeltner, Marco; Hämmerle, Christoph H F; Jung, Ronald E; Thoma, Daniel S
2018-04-01
To assess peri-implant soft tissue dimensions at implant sites, previously augmented with a collagen matrix (VCMX) or an autogenous subepithelial connective tissue graft (SCTG), between crown insertion and 1 year. Twenty patients with single-tooth implants received soft tissue augmentation prior to abutment connection randomly using VCMX or SCTG. Following abutment connection 3 months later, final reconstructions were fabricated and inserted (baseline). Patients were recalled at 6 months (6M) and at 1 year (FU-1). Measurements included clinical data, soft tissue thickness, volumetric outcomes and patient-reported outcome measures (PROMs). The buccal soft tissue thickness showed a median decrease of -0.5 mm (-1.0;0.3) (VCMX) and 0.0 mm (-0.5;1.0) (SCTG) (p = .243) up to FU-1. The soft tissue volume demonstrated a median decrease between BL and FU-1 of -0.1 mm (-0.2;0.0) (p = .301) for VCMX and a significant decrease of -0.2 mm (-0.4; -0.1) (p = .002) for SCTG, respectively. Intergroup comparisons did not reveal any significant differences between the groups for peri-implant soft tissue dimensions and changes up to FU-1 (p > .05). PROMs did not show any significant changes over time nor differences between the groups. Between crown insertion and 1 year, the buccal peri-implant soft tissue dimensions remained stable without relevant differences between sites that had previously been grafted with VCMX or SCTG. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Soft tissue augmentation around osseointegrated and uncovered dental implants: a systematic review.
Bassetti, Renzo G; Stähli, Alexandra; Bassetti, Mario A; Sculean, Anton
2017-01-01
The aim was to compile the current knowledge about the efficacy of different soft tissue correction methods around osseointegrated, already uncovered and/or loaded (OU/L) implants with insufficient soft tissue conditions. Procedures to increase peri-implant keratinized mucosa (KM) width and/or soft tissue volume were considered. Screening of two databases: MEDLINE (PubMed) and EMBASE (OVID), and manual search of articles were performed. Human studies reporting on soft tissue augmentation/correction methods around OU/L implants up to June 30, 2016, were considered. Quality assessment of selected full-text articles to weight risk of bias was performed using the Cochrane collaboration's tool. Overall, four randomized controlled trials (risk of bias = high/low) and five prospective studies (risk of bias = high) were included. Depending on the surgical techniques and graft materials, the enlargement of keratinized tissue (KT) ranged between 1.15 ± 0.81 and 2.57 ± 0.50 mm. The apically positioned partial thickness flap (APPTF), in combination with a free gingival graft (FGG), a subepithelial connective tissue graft (SCTG), or a xenogeneic graft material (XCM) were most effective. A coronally advanced flap (CAF) combined with SCTG in three, combined with allogenic graft materials (AMDA) in one, and a split thickness flap (STF) combined with SCTG in another study showed mean soft tissue recession coverage rates from 28 to 96.3 %. STF combined with XCM failed to improve peri-implant soft tissue coverage. The three APPTF-techniques combined with FGG, SCTG, or XCM achieved comparable enlargements of peri-implant KT. Further, both STF and CAF, both in combination with SCTG, are equivalent regarding recession coverage rates. STF + XCM and CAF + AMDA did not reach significant coverage. In case of soft tissue deficiency around OU/L dental implants, the selection of both an appropriate surgical technique and a suitable soft tissue graft material is of utmost clinical relevance.
Mardinger, Ofer; Vered, Marilena; Chaushu, Gavriel; Nissan, Joseph
2012-06-01
Intrasocket reactive soft tissue can be used for primary closure during augmentation of infected extraction sites exhibiting severe bone loss prior to implant placement. The present study evaluated the histological characteristics of the initially used intrasocket reactive soft tissue, the overlying soft tissue, and the histomorphometry of the newly formed bone during implant placement. Thirty-six consecutive patients (43 sites) were included in the study. Extraction sites demonstrating extensive bone loss on preoperative periapical and panoramic radiographs served as inclusion criteria. Forty-three implants were inserted after a healing period of 6 months. Porous bovine xenograft bone mineral was used as a single bone substitute. The intrasocket reactive soft tissue was sutured over the grafting material to seal the coronal portion of the socket. Biopsies of the intrasocket reactive soft tissue at augmentation, healed mucosa, and bone cores at implant placement were retrieved and evaluated. The intrasocket reactive soft tissue demonstrated features compatible with granulation tissue and long junctional epithelium. The mucosal samples at implant placement demonstrated histopathological characteristics of keratinized mucosa with no residual elements of granulation tissue. Histomorphometrically, the mean composition of the bone cores was - vital bone 40 ± 19% (13.7-74.8%); bone substitute 25.7 ± 13% (0.6-51%); connective tissue 34.3 ± 15% (13.8-71.9%). Intrasocket reactive soft tissue used for primary closure following ridge augmentation is composed of granulation tissue and long junctional epithelium. At implant placement, clinical and histological results demonstrate its replacement by keratinized gingiva. The histomorphometrical results reveal considerable bone formation. Fresh extraction sites of hopeless teeth demonstrating chronic infection and severe bone loss may be grafted simultaneously with their removal. © 2010 Wiley Periodicals, Inc.
Soft tissue wound healing around teeth and dental implants.
Sculean, Anton; Gruber, Reinhard; Bosshardt, Dieter D
2014-04-01
To provide an overview on the biology and soft tissue wound healing around teeth and dental implants. This narrative review focuses on cell biology and histology of soft tissue wounds around natural teeth and dental implants. The available data indicate that: (a) Oral wounds follow a similar pattern. (b) The tissue specificities of the gingival, alveolar and palatal mucosa appear to be innately and not necessarily functionally determined. (c) The granulation tissue originating from the periodontal ligament or from connective tissue originally covered by keratinized epithelium has the potential to induce keratinization. However, it also appears that deep palatal connective tissue may not have the same potential to induce keratinization as the palatal connective tissue originating from an immediately subepithelial area. (d) Epithelial healing following non-surgical and surgical periodontal therapy appears to be completed after a period of 7–14 days. Structural integrity of a maturing wound between a denuded root surface and a soft tissue flap is achieved at approximately 14-days post-surgery. (e) The formation of the biological width and maturation of the barrier function around transmucosal implants requires 6–8 weeks of healing. (f) The established peri-implant soft connective tissue resembles a scar tissue in composition, fibre orientation, and vasculature. (g) The peri-implant junctional epithelium may reach a greater final length under certain conditions such as implants placed into fresh extraction sockets versus conventional implant procedures in healed sites. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Soft tissue remodeling technique as a non-invasive alternative to second implant surgery.
Vela, Xavier; Méndez, Víctor; Rodríguez, Xavier; Segalà, Maribel; Gil, Jaime A
2012-01-01
It is currently accepted that success in implant-supported restorations is based not only on osseointegration, but also on achieving the esthetic outcome of natural teeth and healthy soft tissues. The socalled "pink esthetic" has become the main challenge with implant-supported rehabilitations in the anterior area. This is especially difficult in the cases with two adjacent implants. Two components affect the final periimplant gingiva: a correct bone support, and a sufficient quantity and quality of soft tissues. Several papers have emphasized the need to regenerate and preserve the bone after extractions, or after the exposure of the implants to the oral environment. The classical implantation protocol entails entering the working area several times and always involves the surgical manipulation of peri-implant tissues. Careful surgical handling of the soft tissues when exposing the implants and placing the healing abutments (second surgery) helps the clinician to obtain the best possible results, but even so there is a loss of volume of the tissues as they become weaker and more rigid after each procedure. The present study proposes a new protocol that includes the connective tissue graft placement and the soft tissues remodeling technique, which is based on the use of the ovoid pontics. This technique may help to minimize the logical scar reaction after the second surgery and to improve the final emergence profile.
Wiesner, Günter; Esposito, Marco; Worthington, Helen; Schlee, Markus
2010-01-01
Nothing to declare. To evaluate whether connective tissue grafts performed at implant placement could be effective in augmenting peri-implant soft tissues. Ten partially edentulous patients requiring at least one single implant in the premolar or molar areas of both sides of the mandible were randomised to have one side augmented at implant placement with a connective soft tissue graft harvested from the palate or no augmentation. After 3 months of submerged healing, abutments were placed and within 1 month definitive crowns were permanently cemented. Outcome measures were implant success, any complications, peri-implant marginal bone level changes, patient satisfaction and preference, thickness of the soft tissues and aesthetics (pink aesthetic score) evaluated by an independent and blinded assessor 1 year after loading. One year after loading, no patients dropped out, no implants failed and no complications occurred. Both groups lost statistically significant amounts of peri-implant bone 1 year after loading (0.8 mm in the grafted group and 0.6 mm in the non-grafted group), but there was no statistically significant difference between groups. Soft tissues at augmented sites were 1.3 mm thicker (P < 0.001) and had a significantly better pink aesthetic score (P < 0.001). Patients were highly satisfied (no statistically significant differences between treatments) though they preferred the aesthetics of the augmented sites (P = 0.031). However, five patients would not undergo the grafting procedure again and two were uncertain. Connective tissue grafts are effective in increasing soft tissue thickness, thus improving aesthetics. Longer follow-ups are needed to evaluate the stability of peri-implant tissues over time.
Nakamoto, Tetsuji; Kanao, Masato; Kondo, Yusuke; Kajiwara, Norihiro; Masaki, Chihiro; Takahashi, Tetsu; Hosokawa, Ryuji
2012-12-01
The aims of this study were to (1) evaluate the basic nature of soft tissue surrounding maxillary anterior implants by simultaneous measurements of blood flow and surface temperature and (2) analyze differences with and without bone grafting associated with implant placement to try to detect the signs of surface morphology change. Twenty maxillary anterior implant patients, 10 bone grafting and 10 graftless, were involved in this clinical trial. Soft tissue around the implant was evaluated with 2-dimensional laser speckle imaging and a thermograph. Blood flow was significantly lower in attached gingiva surrounding implants in graftless patients (P = 0.0468). On the other hand, it was significantly lower in dental papillae (P = 0.0254), free gingiva (P = 0.0198), and attached gingiva (P = 0.00805) in bone graft patients. Temperature was significantly higher in free gingiva (P = 0.00819) and attached gingiva (P = 0.00593) in graftless patients, whereas it was significantly higher in dental papilla and free gingiva in implants with bone grafting. The results suggest that simultaneous measurements of soft-tissue blood flow and temperature is a useful technique to evaluate the microcirculation of soft tissue surrounding implants.
Soft Tissue Surgical Procedures for Optimizing Anterior Implant Esthetics
Ioannou, Andreas L.; Kotsakis, Georgios A.; McHale, Michelle G.; Lareau, Donald E.; Hinrichs, James E.; Romanos, Georgios E.
2015-01-01
Implant dentistry has been established as a predictable treatment with excellent clinical success to replace missing or nonrestorable teeth. A successful esthetic implant reconstruction is predicated on two fundamental components: the reproduction of the natural tooth characteristics on the implant crown and the establishment of soft tissue housing that will simulate a healthy periodontium. In order for an implant to optimally rehabilitate esthetics, the peri-implant soft tissues must be preserved and/or augmented by means of periodontal surgical procedures. Clinicians who practice implant dentistry should strive to achieve an esthetically successful outcome beyond just osseointegration. Knowledge of a variety of available techniques and proper treatment planning enables the clinician to meet the ever-increasing esthetic demands as requested by patients. The purpose of this paper is to enhance the implant surgeon's rationale and techniques beyond that of simply placing a functional restoration in an edentulous site to a level whereby an implant-supported restoration is placed in reconstructed soft tissue, so the site is indiscernible from a natural tooth. PMID:26124837
Choi, Jay-Yong; Moon, Ik-Sang; Yun, Jeong-Ho; Park, Kwang-Ho; Huh, Jong-Ki; Lee, Dong-Won
2016-09-01
The aim of this animal study was to examine the effects of thread size in the implant neck area on peri-implant tissues in terms of BIC and hard- and soft-tissue dimensions. Six Beagle dogs received experimental implants in the mandible 3 month after the removal of premolars and first molars (P2, P3, P4, and M1). Two different types of implants were installed in each animal: Anyone microthread(®) as Group 1 and Anyone(®) as Group 2. Resonance frequency test, intraoral radiography, micro-CT, and histomorphometry were used to evaluate peri-implant tissue after implantation periods of 4 and 8 weeks. No remarkable complication was observed during the healing period in either group. Resonance frequency testing revealed no significant difference between groups. In radiographic evaluation, Group 2 showed more bone loss than Group 1. However, this difference was not statistically significant. In the micro-CT analysis, BIC and BIV values and soft-tissue height were not significant in both groups. Histological analysis revealed no significant difference in BIC ratio, bone density, or bone loss between groups. However, soft-tissue height was significantly greater in Group 2 than in Group 1 (P = 0.0004). No difference in peri-implant hard or soft tissues was observed according to thread size in the implant neck area. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Willbold, Elmar; Reebmann, Mattias; Jeffries, Richard; Witte, Frank
2013-11-01
Solid metallic implants in soft or hard tissues are serious challenges for histological processing. However, metallic implants are more frequently used in e.g. cardiovascular or orthopaedic therapies. Before clinical use, these devices need to be tested thoroughly in a biological environment and histological analysis of their biocompatibility is a major requirement. To allow the histological analysis of metallic implants in tissues especially in calcified hard tissues, we describe a method for embedding these tissues in the resin Technovit 9100 New and removing the metallic implants by electrochemical dissolution. With the combination of these two processes, we are able to achieve 5 μm thick sections from soft or hard tissues with a superior preservation of tissue architecture and especially the implant-tissue interface. These sections can be stained by classical stainings, immunohistochemical and enzymehistochemical as well as DNA-based staining methods.
Changes of the peri-implant soft tissue thickness after grafting with a collagen matrix.
Zafiropoulos, Gregory-George; Deli, Giorgio; Hoffmann, Oliver; John, Gordon
2016-01-01
The aim of this study was to determine the treatment outcome of the use of a porcine monolayer collagen matrix (mCM) to increase soft-tissue volume as a part of implant site development. Implants were placed in single sites in 27 patients. In the test group, mCM was used for soft-tissue augmentation. No graft was placed in the control group. Soft-tissue thickness (STTh) was measured at the time of surgery (T0) and 6 months postoperatively (T1) at two sites (STTh 1, 1 mm below the gingival margin; STTh 2, 3 mm below the mucogingival margin). Significant increases ( P < 0.001) in STTh (STTh 1 = 1.06 mm, 117%; STTh 2 = 0.89 mm, 81%) were observed in the test group. Biopsy results showed angiogenesis and mature connective tissue covered by keratinized epithelium. Within the limitations of this study, it could be concluded that mCM leads to a significant increase of peri-implant soft-tissue thickness, with good histological integration and replacement by soft tissue and may serve as an alternative to connective tissue grafting.
Sicilia, Alberto; Quirynen, Marc; Fontolliet, Alain; Francisco, Helena; Friedman, Anton; Linkevicius, Tomas; Lutz, Rainer; Meijer, Henny J; Rompen, Eric; Rotundo, Roberto; Schwarz, Frank; Simion, Massimo; Teughels, Wim; Wennerberg, Ann; Zuhr, Otto
2015-09-01
Several surgical techniques and prosthetic devices have been developed in the last decades, aiming to improve aesthetic, hygienic and functional outcomes that may affect the peri-implant tissues, such as procedures of bone and soft tissue augmentation and the use of custom-made abutments of titanium and zirconium. Three systematic reviews, based on randomized clinical trials and prospective studies covering the above reported topics were analysed, and the detected evidence was exposed to interactive experts' discussion during the group's and general assembly's meetings of the 4th EAO Consensus Conference. The results are reported using the following abbreviations: S-T: short-term evidence, M-T: medium-term evidence; L-T: long-term evidence; LE: limited evidence. Soft tissue augmentation procedures may be indicated for the increase of soft tissue thickness and keratinized tissue, the reduction of interproximal peri-implant bone loss, and the coverage of shallow peri-implant soft tissue recessions (S-T, LE), L-T is lacking. Guided bone regeneration approaches (GBR) showed efficacy when used for ridge reconstruction after the complete healing of the soft tissues (S-T & L-T), and the stability of the augmented bone may play a role in the maintenance of the soft tissue position and dimensions (LE). No significant differences were observed between titanium and zirconia abutments when evaluating probing pocket depth, bleeding on probing, marginal bone levels and mucosal recessions. Zirconia abutments were associated with more biological complications but demonstrated superiority in terms of achieving natural soft tissue colour (S-T). © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Influence of Abutment Color and Mucosal Thickness on Soft Tissue Color.
Ferrari, Marco; Carrabba, Michele; Vichi, Alessandro; Goracci, Cecilia; Cagidiaco, Maria Crysanti
Zirconia (ZrO₂) and titanium nitride (TiN) implant abutments were introduced mainly for esthetic purposes, as titanium's gray color can be visible through mucosal tissues. This study was aimed at assessing whether ZrO₂ and TiN abutments could achieve better esthetics in comparison with titanium (Ti) abutments, regarding the appearance of soft tissues. Ninety patients were included in the study. Each patient was provided with an implant (OsseoSpeed, Dentsply Implant System). A two-stage surgical technique was performed. Six months later, surgical reentry was performed. After 1 week, provisional restorations were screwed onto the implants. After 8 weeks, implant-level impressions were taken and soft tissue thickness was recorded, ranking thin (≤ 2 mm) or thick (≥ 2 mm). Patients were randomly allocated to three experimental groups, based on abutment type: (1) Ti, (2) TiN, and (3) ZrO₂. After 15 weeks, the final restorations were delivered. The mucosal area referring to each abutment was measured for color using a clinical spectrophotometer (Easyshade, VITA); color measurements of the contralateral areas referring to natural teeth were performed at the same time. The data were collected using the Commission Internationale de l'Eclairage (CIE) L*a*b* color system, and ΔE was calculated between peri-implant and contralateral soft tissues. A critical threshold of ΔE = 3.7 was selected. The chi-square test was used to identify statistically significant differences in ΔE between thin and thick mucosal tissues and among the abutment types. Three patients were lost at follow-up. No statistically significant differences were noticed as to the abutment type (P = .966). Statistically significant differences in ΔE were recorded between thick and thin peri-implant soft tissues (P < .001). Only 2 out of 64 patients with thick soft tissues showed a ΔE higher than 3.7: 1 in the TiN group and 1 in the ZrO₂ group. All the patients with thin soft tissues reported color changes that exceeded the critical threshold. The different abutment materials showed comparable results in terms of influence on soft tissue color. Regarding peri-implant soft tissue thickness, the influence of the tested abutments on soft tissue color became clinically relevant for values ≤ 2 mm.
Puisys, Algirdas; Vindasiute, Egle; Linkevciene, Laura; Linkevicius, Tomas
2015-04-01
To evaluate the efficiency of acellular dermal matrix membrane to augment vertical peri-implant soft tissue thickness during submerged implant placement. Forty acellular dermal matrix-derived allogenic membranes (AlloDerm, BioHorizons, Birmingham, AL, USA) and 42 laser-modified surface internal hex implants (BioHorizons Tapered Laser Lok, Birmingham, AL, USA) were placed in submerged approach in 40 patients (15 males and 25 females, mean age 42.5 ± 1.7) with a thin vertical soft tissue thickness of 2 mm or less. After 3 months, healing abutments were connected to implants, and the augmented soft tissue thickness was measured with periodontal probe. The gain in vertical soft tissue volume was calculated. Mann-Whitney U-test was applied and significance was set to 0.05. All 40 allografts healed successfully. Thin soft tissue before augmentation had an average thickness of 1.54 ± 0.51 mm SD (range, 0.5-2.0 mm, median 1.75 mm), and after soft tissue augmentation with acellular dermal matrix, thickness increased to 3.75 ± 0.54 mm SD (range, 3.0-5.0 mm, median 4.0 mm) at 3 months after placement. This difference between medians was found to be statistically significant (P < 0.001). Mean increase in soft tissue thickness was 2.21 ± 0.85 mm SD (range, 1.0-4.5 mm, median 2.0 mm). It can be concluded that acellular dermal matrix membrane can be successfully used for vertical soft tissue augmentation. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Benito-González, Fernando; Benito, Jose; Sánchez, Luis Alberto Guardado; Estevez Alonso, Santiago; Muñoz Herrera, Angel; Batuecas-Caletrio, Angel
2014-09-01
The objective was to report the effectiveness of salvage treatment in soft tissue infection around cochlear implants with an absorbable gentamicin collagen sheet and a periosteum and skin rotation flaps. Three patients with cochlear implant and persistent surrounding soft tissue infection are included. All of them underwent antibiotic treatment prior to surgery without any response. In this study preoperative and postoperative audiograms were practiced. Surgical excision of infectious skin and a periosteum and skin rotation flaps were performed. The cochlear implant was refixed in the temporal bone and a gentamicin-impregnated collagen sheet was located covering the cochlear implant. headings In all patients with soft tissue infection around the cochlear implant, infection was completely resolved. It was not necessary to remove the device in any case. The use of an absorbable gentamicin-impregnated collagen sheet is not described for the management of soft tissue complications in pediatric cochlear implant patients. The local application of high concentrations of antibiotic administered by this sheet may be effective against resistant bacteria and, in conjunction with surgery, may resolve this type of complications.
Cairo, Francesco; Barbato, Luigi; Tonelli, Paolo; Batalocco, Guido; Pagavino, Gabriella; Nieri, Michele
2017-07-01
Peri-implant soft tissue may be critical to prevent inflammation and promote gingival margin stability. The purpose of this randomized clinical trial (RCT) is to compare xenogeneic collagen matrix (XCM) versus connective tissue graft (CTG) to increase buccal soft tissue thickness at implant site. Soft tissue augmentation with XCM (test) or CTG (control) was performed at 60 implants in 60 patients at the time of implant uncovering. Measurements were performed by a blinded examiner at baseline, 3 and 6 months. Outcome measures included buccal soft tissue thickness (GT), apico-coronal keratinized tissue (KT), chair time and post-operative discomfort. Visual Analogue Scale (VAS) was used to evaluate patient satisfaction. After 6 months, the final GT increase was 0.9 ± 0.2 in the XCM group and 1.2 ± 0.3 mm in the CTG group, with a significant difference favouring the control group (0.3 mm; p = .0001). Both procedures resulted in similar final KT amount with no significant difference between treatments. XCM was associated with significant less chair-time (p < .0001), less post-operative pain (p < .0001), painkillers intake (p < .0001) and higher final satisfaction than CTG (p = .0195). CTG was more effective than XCM to increase buccal peri-implant soft tissue thickness. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Lin, Cho-Ying; Chen, Zhaozhao; Pan, Whei-Lin; Wang, Hom-Lay
2018-05-01
To achieve a predictable esthetic and functional outcome, soft tissue augmentation has become popular in implant treatment. The aim of this systematic review and meta-analysis was to assess the influence of different timing for soft tissue augmentation during implant treatment on soft tissue conditions and its stability. Electronic and manual searches for articles written in English up to September 2017 were performed by two independent reviewers. Human clinical studies with the purpose of evaluating outcomes (at least 3-month follow-up) of autogenous soft tissue graft for augmentation during implant treatment, either simultaneous or after implant placement (staged), were included. Cumulative changes of keratinized tissue width (KTW), soft tissue thickness (STT), and mid-buccal mucosal recession (MR) data were analyzed with a random-effects model to compare the postoperative outcomes. Twenty-nine human studies (eight randomized clinical trials, six cohort studies, and 15 case series) that met the inclusion criteria were included. For the overall data, the weighted mean STT gain (1 year after surgery) was 1.03 mm (95% CI: 0.78-1.29 mm), among which the simultaneous group was 1.12 mm (95% CI: 0.75-1.49 mm) and staged group (3-6 months after implant placement) was 0.95 mm (95% CI: 0.58-1.31 mm). There was no statistically significant difference in KTW and MR between 3 months and more than 3 months after surgery. This review revealed that the stability of soft tissue, in terms of KTW and mid-buccal MR, can be obtained 3 months after surgery. There is no difference between simultaneous and staged soft tissue augmentation during implant treatment, and both procedures significantly enhance KTW and STT. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Kumar, Vinay V; Jacob, P C; Kuriakose, Moni A
2016-12-01
In patients with reconstructed mandibles using free fibula flaps, management of soft tissues around implants supporting dental rehabilitation, is often a clinical problem. The aim of this paper is to describe a new technique, namely "Sub-periosteal dissection and denture-guided epithelial regeneration (SD-DGER)", as a method of peri-implant soft tissue management in these patients. The technique consists of performing a subperiosteal dissection with creation of buccal and lingual flaps. These flaps form the buccal and lingual vestibule. Implants are placed and an interim denture is immediately loaded onto the implants to guide the regenerated epithelium. A keratinized mucosal layer is formed on the bare fibula bone in six months time. This technique was successful in producing fixed keratinized epithelial tissue around implants in patients with mandibles reconstructed using the free fibula flap in patients who did not undergo radiotherapy. The sub-periosteal dissection with denture guided epithelial regeneration is a predictable form of peri-implant soft tissue management in selected patients with reconstructed jaws.
Parthasarathy, Harinath; Ramachandran, Lakshmi; Tadepalli, Anupama; Ponnaiyan, Deepa
2017-04-01
Alveolar ridge deficiency is a common clinical consequence following tooth loss due to chronic periodontitis complicating ideal implant placement. Advanced hard and soft tissue augmentation procedures have been developed in the recent past with predictable clinical outcomes. A male patient presented with a Grade III mobile upper right central incisor associated with advanced bone loss and soft tissue deficit. Following extraction of tooth #11, socket augmentation was done using an autogenous cortico-cancellous block graft and subsequent soft tissue augmentation was done with palatal connective tissue graft. At the end of six months, a tapered self tapping implant fixture was placed with adequate primary stability and after eight weeks, second stage implant surgery was done with the Misch technique in order to recreate papillae and the implant was prosthetically restored. The alveolar ridge was adequately recontoured following the staged surgical protocol. The implant was well integrated at the end of 15 months. Execution of sequential surgical procedures in a highly deficient edentulous site made it possible to achieve of optimal pink and white aesthetics with stable implant supported fixed prosthesis.
Changes of the peri-implant soft tissue thickness after grafting with a collagen matrix
Zafiropoulos, Gregory-George; Deli, Giorgio; Hoffmann, Oliver; John, Gordon
2016-01-01
Background: The aim of this study was to determine the treatment outcome of the use of a porcine monolayer collagen matrix (mCM) to increase soft-tissue volume as a part of implant site development. Materials and Methods: Implants were placed in single sites in 27 patients. In the test group, mCM was used for soft-tissue augmentation. No graft was placed in the control group. Soft-tissue thickness (STTh) was measured at the time of surgery (T0) and 6 months postoperatively (T1) at two sites (STTh 1, 1 mm below the gingival margin; STTh 2, 3 mm below the mucogingival margin). Results: Significant increases (P < 0.001) in STTh (STTh 1 = 1.06 mm, 117%; STTh 2 = 0.89 mm, 81%) were observed in the test group. Biopsy results showed angiogenesis and mature connective tissue covered by keratinized epithelium. Conclusions: Within the limitations of this study, it could be concluded that mCM leads to a significant increase of peri-implant soft-tissue thickness, with good histological integration and replacement by soft tissue and may serve as an alternative to connective tissue grafting. PMID:28298828
Vignoletti, Fabio; Nunez, Javier; Sanz, Mariano
2014-04-01
To review the biological processes of wound healing following periodontal and periimplant plastic surgery when different technologies are used in a) the coverage of root and implant dehiscences, b) the augmentation of keratinized tissue (KT) and c) the augmentation of soft tissue volume. An electronic search from The National Library of Medicine (MEDLINE-PubMed) was performed: English articles with research focus in oral soft tissue regeneration, providing histological outcomes, either from animal experimental studies or human biopsy material were included. Barrier membranes, enamel matrix derivatives, growth factors, allogeneic and xenogeneic soft tissue substitutes have been used in soft tissue regeneration demonstrating different degrees of regeneration. In root coverage, these technologies were able to improve new attachment, although none has shown complete regeneration. In KT augmentation, tissue-engineered allogenic products and xenogeneic collagen matrixes demonstrated integration within the host connective tissue and promotion of keratinization. In soft tissue augmentation and peri-implant plastic surgery there are no histological data currently available. Soft tissue substitutes, growth differentiation factors demonstrated promising histological results in terms of soft tissue regeneration and keratinization, whereas there is a need for further studies to prove their added value in soft tissue augmentation. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Bosc, Romain; Tijou, Antoine; Rosi, Giuseppe; Nguyen, Vu-Hieu; Meningaud, Jean-Paul; Hernigou, Philippe; Flouzat-Lachaniette, Charles-Henri; Haiat, Guillaume
2018-06-01
The acetabular cup (AC) implant primary stability is an important determinant for the success of cementless hip surgery but it remains difficult to assess the AC implant fixation in the clinic. A method based on the analysis of the impact produced by an instrumented hammer on the ancillary has been developed by our group (Michel et al., 2016a). However, the soft tissue thickness present around the acetabulum may affect the impact response, which may hamper the robustness of the method. The aim of this study is to evaluate the influence of the soft tissue thickness (STT) on the acetabular cup implant primary fixation evaluation using impact analyses. To do so, different AC implants were inserted in five bovine bone samples. For each sample, different stability conditions were obtained by changing the cavity diameter. For each configuration, the AC implant was impacted 25 times with 10 and 30 mm of soft tissues positioned underneath the sample. The averaged indicator I m was determined based on the amplitude of the signal for each configuration and each STT and the pull-out force was measured. The results show that the resonance frequency of the system increases when the value of the soft tissue thickness decreases. Moreover, an ANOVA analysis shows that there was no significant effect of the value of soft tissue thickness on the values of the indicator I m (F = 2.33; p-value = 0.13). This study shows that soft tissue thickness does not appear to alter the prediction of the acetabular cup implant primary fixation obtained using the impact analysis approach, opening the path towards future clinical trials. Copyright © 2018 Elsevier Ltd. All rights reserved.
New Soft Tissue Implants Using Organic Elastomers
NASA Astrophysics Data System (ADS)
Ku, David N.
Typical biomaterials are stiff, difficult to manufacture, and not initially developed for medical implants. A new biomaterial is proposed that is similar to human soft tissue. The biomaterial provides mechanical properties similar to soft tissue in its mechanical and physical properties. Characterization is performed for modulus of elasticity, ultimate strength and wear resistance. The material further exhibits excellent biocompatibility with little toxicity and low inflammation. The material can be molded into a variety of anatomic shapes for use as a cartilage replacement, heart valve, and reconstructive implant for trauma victims. The biomaterial may be suitable for several biodevices of the future aimed at soft-tissue replacements.
Baltacıoğlu, Esra; Korkmaz, Fatih Mehmet; Bağış, Nilsun; Aydın, Güven; Yuva, Pınar; Korkmaz, Yavuz Tolga; Bağış, Bora
2014-01-01
This case report presents an implant-aided prosthetic treatment in which peri-implant plastic surgery techniques were applied in combination to satisfactorily attain functional aesthetic expectations. Peri-implant plastic surgery enables the successful reconstruction and restoration of the balance between soft and hard tissues and allows the option of implant-aided fixed prosthetic rehabilitation. PMID:25489351
Romanos, Georgios E; Belikov, Andrey V; Skrypnik, Alexei V; Feldchtein, Felix I; Smirnov, Michael Z; Altshuler, Gregory B
2015-07-01
Uncovering implants with lasers, while bloodless, has been associated with a risk of implant and bone overheating. The present study evaluated the effect of using a new generation of high-power diode lasers on the temperature of a dental implant and the surrounding tissues using an in vitro model. The implant temperature was measured at three locations using micro thermocouples. Collateral thermal damage of uncovered soft tissues was evaluated using NTBC stain. Implant temperature rise during and collateral thermal soft-tissue damage following implant uncovering with and without tissue air-cooling was studied using both the classic operational mode and the new thermo-optically powered (TOP) technology. For the classic surgical mode using a cork-initiated tip and constant laser power set at 3.4 W, the maximum temperature rise in the coronal and apical parts of the implant was 23.2 ± 4.1°С and 9.5 ± 1.8°С, respectively, while 1.5 ± 0.5 mm of collateral thermal damage of the soft tissue surrounding the implant model occurred. Using the TOP surgical tip with constant laser power reduced implant overheating by 30%; collateral thermal soft-tissue damage was 0.8 ± 0.2 mm. Using the TOP surgical mode with a tip temperature setting of 800°C and air-cooling reduced the implant temperature rise by more than 300%, and only 0.2 ± 0.1 mm of collateral thermal soft-tissue damage occurred, typical for optimized CO2 laser surgery. Furthermore, use of the new generation diode technology (TOP surgical mode) appeared to reduce the time required for implant uncovering by a factor of two, compared to the standard surgical mode. Use of the new generation diode technology (TOP surgical mode) may significantly reduce overheating of dental implants during uncovering and seems to be safer for the adjacent soft and hard tissues. Use of such diode lasers with air-cooling can radically reduce the rise in implant temperatures (by more than three times), potentially making this technology safe and effective for implant uncovering. © 2015 Wiley Periodicals, Inc.
Mueller, Cornelia Katharina; Thorwarth, Michael; Schultze-Mosgau, Stefan
2011-01-01
The structure of peri-implant soft tissue that is regenerated after flapless and flap surgery has been shown to differ. However, its underlying mechanisms are relatively unknown. The present study sought to identify differences in the inflammatory cell infiltration and expression of gene transcripts during transmucosal healing between the two approaches with two different implant designs. All mandibular premolars were removed from 12 minipigs. One month later, four implants (two NobelReplace Tapered Groovy and two NobelPerfect Groovy, Nobel Biocare) were placed in each quadrant. One quadrant was randomized to flapless insertion, while the other was chosen for flap surgery in each animal. Following 1, 2, 4, and 12 weeks of transmucosal implant healing, biopsy specimens were retrieved from the peri-implant soft tissue according to a standardized procedure to avoid crossover effects. Samples were subjected to a leukocyte count and a gene expression analysis. When the flapless placement technique was used, leukocyte influx in the peri-implant soft tissue was significantly smaller compared to open surgery for both implant designs. Gene expression analysis revealed significant overexpression of molecules associated with detoxification and reepithelialization in the flapless group. In contrast, myofibroblast-associated gene transcripts were significantly enriched in the flap surgery group. The present data indicate perpetuation of inflammatory reactions as well as increased fibrotic scar tissue deposition in the peri-implant area following implant placement by the flap approach. Flapless implant insertion results in less inflammation and early reepithelialization, providing the potential for the formation of a fully functioning as well as esthetically preferable peri-implant soft tissue collar.
Anitua, Eduardo; Begoña, Leire; Orive, Gorka
2013-04-01
The aim of this study was to evaluate the split-crest technique with ultrasonic bone surgery for implant placement in patients with narrow ridges, focusing on the status of soft and hard tissues and on implant success rate, at least 6 months after implant loading. During September 2007 and November 2008, 15 patients received 37 implants (BTI implants) with split-crest surgical procedure using ultrasonic bone surgery. Plasma rich in growth factors (PRGF®) was applied during split crest procedure to promote tissue regeneration. Implant surfaces were humidified with PRGF to accelerate osseointegration. Patients were recalled for a final clinical evaluation at least 6 months after implant loading. Clinical assessment included the status of soft and hard tissues around implants, and implants' success rate. Thirty-seven implants in 15 patients were evaluated between July 2009 and January 2010. The status of soft tissues was very good, showing adequate plaque index, bleeding index, and probing depth values. Success rate of implants at the end of follow-up (between 11 and 28 months after insertion) was 100%. Bone ridge was measured and compared at final examination showing a mean ridge expansion of 3.35 mm (SD: 0.34). Split-crest with ultrasonic bone surgery can be considered an effective and safe procedure for narrow ridge expansion. © 2011 Wiley Periodicals, Inc.
López-López, Patricia J; Mareque-Bueno, Javier; Boquete-Castro, Ana; Aguilar-Salvatierra Raya, Antonio; Martínez-González, José M; Calvo-Guirado, José L
2016-01-01
The aim of this animal study was to compare the effects of narrow, concave-straight and wide anatomic healing abutments on changes to soft tissues and crestal bone levels around implants immediately placed into extraction sockets in foxhound dogs. Forty-eight titanium implants (Bredent Medical GMBH, Germany) of the same dimensions were placed in six foxhound dogs. They were divided into two groups (n = 24): test (implants with anatomic abutment) and control (implants with concave-straight abutment). The implants were inserted randomly in the post extraction sockets of P2 , P3 , P4, and M1 bilaterally in six dogs. After eight and twelve weeks, the animals were sacrificed and samples extracted containing the implants and the surrounding soft and hard tissues. Soft tissue and crestal bone loss (CBL) were evaluated by histology and histomorphometry. All implants were clinically and histologically osseointegrated. Healing patterns were examined microscopically at eight and twelve weeks. After eight and twelve weeks, for hard tissues, the distance from the implant shoulder to the first bone-to-implant contact (IS-C) was higher for control group in the lingual aspect with statistical significance (P < 0.05). For soft tissues (STL), the distance from the top of the peri-implant mucosa to the apical portion of the junction epithelium (PM-Je) was significantly less on the lingual aspect in the test group (with wider abutment) at eight and twelve weeks (P < 0.05). The distance from the top of the apical portion of the junction epithelium to the first bone-to-implant contact (Je-C) was significantly higher in the test group (wider abutment) in the lingual aspect at eight and twelve weeks (P < 0.05). There was no connective tissue contact with any abutment surface. Within the limitations of this animal study, anatomic healing abutments protect soft and hard tissues and reduce crestal bone resorption compared with concave-straight healing abutments. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Cafiero, Carlo; Marenzi, Gaetano; Blasi, Andrea; Siciliano, Vincenzo Iorio; Nicolò, Michele; Sammartino, Gilberto
2013-10-01
To assess soft and hard tissues healing at immediate transmucosal implants placed into maxillary molar region with collagen membranes uncovered. Twenty subjects received 20 immediate transmucosal implants placed in maxillary molar extraction sockets. Periimplant marginal defects were treated according to the principles of guided bone regeneration by means of deproteinized bovine bone mineral particles in conjunction with collagen membrane. Flaps were repositioned and sutured, allowing nonsubmerged, transmucosal soft tissues healing. The collagen membranes adapted around implant neck were uncovered. No implants were lost during the 1-year observation period yielding a survival rate of 100%. No postsurgical wound healing complications were observed. No degranulation of grafting material was reported. The results of this 12-month prospective study showed that the exposure of collagen membrane at time of the flap suturing does not represent a limitation for the soft and hard tissues healing at immediate transmucosal implants placed into maxillary molar extraction sites.
Zafiropoulos, Gregor-Georg; John, Gordon
2017-05-01
The aim of this study was to determine the treatment outcome of the use of a porcine monolayer collagen matrix (mCM) to augment peri-implant soft tissue in conjunction with immediate implant placement as an alternative to patient's own connective tissue. A total of 27 implants were placed immediately in 27 patients (14 males and 13 females, with a mean age of 52.2 years) with simultaneous augmentation of the soft tissue by the use of a mCM. The patients were randomly divided into two groups: Group I: An envelope flap was created and mCM was left coronally uncovered, and group II: A coronally repositioned flap was created and the mCM was covered by the mucosa. Soft-tissue thickness (STTh) was measured at the time of surgery (T0) and 6 months postoperatively (T1) using a customized stent. Cone beam computed tomographies (CBCTs) were taken from 12 representative cases at T1. A stringent plaque control regimen was enforced in all the patients during the 6-month observation period. Mean STTh change was similar in both groups (0.7 ± 0.2 and 0.7 ± 0.1 mm in groups I and II respectively). The comparison of STTh between T0 and T1 showed a statistically significant increase of soft tissue in both groups I and II as well as in the total examined population (p < 0.001). The STTh change as well as matrix thickness loss were comparable in both groups (p > 0.05). The evaluation of the CBCTs did not show any signs of resorption of the buccal bone plate. Within the limitations of this study, it could be concluded that the collagen matrix used in conjunction with immediate implant placement leads to an increased thickness of peri-implant soft tissue independent of the flap creation technique and could be an alternative to connective tissue graft. The collagen matrix used seems to be a good alternative to patient's own connective tissue and could be used for the soft tissue augmentation around dental implants.
2014-05-14
2002). "Healing after standardized clinical probing of perlimlant soft tissue seal; a histomorphometric study in dogs." Clinical oral Implants...implant and periodontal tissues . A study in the beagle dog." Clin Oral Implants Res3(1): 9-16. Luterbacher, S., Mayfield, L. (2000). "Diagnostic...encapsulation around the implant and soft tissue . This type of healing and encapsulation led to inflammation, infection, mobility and failure of the
Thoma, Daniel S; Naenni, Nadja; Figuero, Elena; Hämmerle, Christoph H F; Schwarz, Frank; Jung, Ronald E; Sanz-Sánchez, Ignacio
2018-03-01
To review the dental literature in terms of soft tissue augmentation procedures and their influence on peri-implant health or disease in partially and fully edentulous patients. A MEDLINE search from 1966 to 2016 was performed to identify controlled clinical studies comparing soft tissue grafting versus no soft tissue grafting (maintenance) or two types of soft tissue grafting procedures at implant sites. The soft tissue grafting procedures included either an increase of keratinized tissue or an increase of the thickness of the peri-implant mucosa. Studies reporting on the peri-implant tissue health, as assessed by bleeding or gingival indices, were included in the review. The search was complemented by an additional hand search of all selected full-text articles and reviews published between 2011 and 2016. The initial search yielded a total number of 2,823 studies. Eligible studies were selected based on the inclusion criteria (finally included: four studies on gain of keratinized tissue; six studies on gain of mucosal thickness) and quality assessments conducted. Meta-analyses were applied whenever possible. Soft tissue grafting procedures for gain of keratinized tissue resulted in a significantly greater improvement of gingival index values compared to maintenance groups (with or without keratinized tissue) [n = 2; WMD = 0.863; 95% CI (0.658; 1.067); p < .001]. For final marginal bone levels, statistically significant differences were calculated in favor of an apically positioned flap (APF) plus autogenous grafts versus all control treatments (APF alone; APF plus a collagen matrix; maintenance without intervention [with or without residual keratinized tissue]) [n = 4; WMD = -0.175 mm; 95% CI: (-0.313; -0.037); p = .013]. Soft tissue grafting procedures for gain of mucosal thickness did not result in significant improvements in bleeding indices over time, but in significantly less marginal bone loss over time [WMD = 0.110; 95% CI: 0.067; 0.154; p < .001] and a borderline significance for marginal bone levels at the study endpoints compared to sites without grafting. Within the limitations of this review, it was concluded that soft tissue grafting procedures result in more favorable peri-implant health: (i) for gain of keratinized mucosa using autogenous grafts with a greater improvement of bleeding indices and higher marginal bone levels; (ii) for gain of mucosal thickness using autogenous grafts with significantly less marginal bone loss. © 2018 The Authors. Clinical Oral Implants Research Published by John Wiley & Sons Ltd.
Interventions for replacing missing teeth: management of soft tissues for dental implants.
Esposito, Marco; Maghaireh, Hassan; Grusovin, Maria Gabriella; Ziounas, Ioannis; Worthington, Helen V
2012-02-15
Dental implants are usually placed by elevating a soft tissue flap, but in some instances, they can also be placed flapless reducing patient discomfort. Several flap designs and suturing techniques have been proposed. Soft tissues are often manipulated and augmented for aesthetic reasons. It is often recommended that implants are surrounded by a sufficient width of attached/keratinised mucosa to improve their long-term prognosis. To evaluate whether (1a) flapless procedures are beneficial for patients, and (1b) which is the ideal flap design; whether (2a) soft tissue correction/augmentation techniques are beneficial for patients, and (2b) which are the best techniques; whether (3a) techniques to increase the peri-implant keratinised mucosa are beneficial for patients, and (3b) which are the best techniques; and (4) which are the best suturing techniques/materials. The following electronic databases were searched: the Cochrane Oral Health Group Trials Register (to 9 June 2011), the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2011, Issue 2), MEDLINE via OVID (1950 to 9 June 2011), EMBASE via OVID (1980 to 9 June 2011). Several dental journals were handsearched. There were no language restrictions. All randomised controlled trials (RCTs) of root-form osseointegrated dental implants, with a follow-up of at least 6 months after function, comparing various techniques to handle soft tissues in relation to dental implants. Outcome measures, according to the different hypotheses, were: prosthetic and implant failures, biological complications, aesthetics evaluated by patients and dentists, postoperative pain, marginal peri-implant bone level changes on periapical radiographs, patient preference, ease of maintenance by patient, soft tissue thickness changes and attached/keratinised mucosa height changes. Screening of eligible studies, assessment of the methodological quality of the trials and data extraction were conducted at least in duplicate and independently by two or more review authors. Trial authors were contacted for missing information. Results were expressed using risk ratios for dichotomous outcomes and mean differences for continuous outcomes with 95% confidence intervals. Seventeen potentially eligible RCTs were identified but only six trials with 138 patients in total could be included. One study was at low risk of bias, two studies were judged to be at unclear risk of bias and three at high risk of bias. Two trials (56 patients) compared flapless placement of dental implants with conventional flap elevation, one trial (10 patients) compared crestal versus vestibular incisions, one trial (20 patients) Erbium:YAG laser versus flap elevation at the second-stage surgery for implant exposure, one split-mouth trial (10 patients) evaluated whether connective tissue graft at implant placement could be effective in augmenting peri-implant tissues, and one trial (40 patients) compared autograft with an animal-derived collagen matrix to increase the height of the keratinised mucosa. On a patient, rather than per implant basis, implants placed with a flapless technique and implant exposures performed with laser induced statistically significantly less postoperative pain than flap elevation. Sites augmented with soft tissues connective grafts showed a better aesthetic and thicker tissues. Both palatal autografts or the use of a porcine-derived collagen matrix are effective in increasing the height of keratinised mucosa at the price of a 0.5 mm recession of peri-implant soft tissues. There were no other statistically significant differences for any of the remaining analyses. There is limited weak evidence suggesting that flapless implant placement is feasible and has been shown to reduce patient postoperative discomfort in adequately selected patients, that augmentation at implant sites with soft tissue grafts is effective in increasing soft tissue thickness improving aesthetics and that one technique to increase the height of keratinised mucosa using autografts or an animal-derived collagen matrix was able to achieve its goal but at the price of a worsened aesthetic outcome (0.5 mm of recession). There is insufficient reliable evidence to provide recommendations on which is the ideal flap design, the best soft tissue augmentation technique, whether techniques to increase the width of keratinised/attached mucosa are beneficial to patients or not, and which are the best incision/suture techniques/materials. Properly designed and conducted RCTs, with at least 6 months of follow-up, are needed to provide reliable answers to these questions.
Vlahovic, Zoran; Markovic, Aleksa; Golubovic, Mileta; Scepanovic, Miodrag; Kalanovic, Milena; Djinic, Ana
2015-11-01
The aim of this study was comparing the effect of flapless vs. flap technique of implant placement on inflammation degree of peri-implant soft tissue, through histopathological analysis. The experiment was conducted on five domestic pigs. Nine weeks after tooth extraction, implants were installed. Each animal received six implants in mandible. According to split-mouth design, randomly one side was used for flapless technique using mini-incision, while on the other side, flap was raised. After 7, 14, 21, 28, and 90 days, the experimental animals were sacrificed. Samples for histopathological analyzes were taken from the buccal side of peri-implant mucosa next to the neck of implants, from three levels. The degree of inflammatory response in the peri-implant soft tissue was estimated through ordinal scores from 0 to 3. In the flap group Score 3 indicating high degree of inflammation was present from day 7 to day 21, in contrast to flapless group where Score 3 was not recorded during the entire follow-up. Three months after implantation, there were no signs of inflammation neither around flap nor around flapless implants. Flapless surgical implantation technique using mini-incision decreases peri-implant soft tissue inflammatory reaction compared with flap surgery. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Cardaropoli, Daniele; Tamagnone, Lorenzo; Roffredo, Alessandro; Gaveglio, Lorena
2015-01-01
In the maxillary arch from premolar to premolar, 26 single dental implants were inserted in fresh extraction sockets and immediately provisionalized. The bone-to-implant gap was grafted with a bovine bone mineral. After 3 months, definitive ceramic crowns were placed. At baseline and after 1 year, the soft tissue horizontal width, mesiodistal papillary level, midfacial gingival level, and pink esthetic score were evaluated. No statistical differences were found between baseline and 1 year for all parameters. Immediate single-tooth implants, with immediate restoration, are capable of maintaining the soft tissue contour and esthetics compared to the pretreatment status.
Schiegnitz, E; Noelken, R; Moergel, M; Berres, M; Wagner, W
2017-06-01
Clinical studies evaluating the influence of the implant design on the preservation of peri-implant keratinized mucosa are rare. The aim of this prospective multicenter study was to investigate the survival, and soft and hard tissue maintenance of an implant with a sloped shoulder configuration, when placed in the posterior mandible. In this study, 24 centers participated and 184 patients receiving 238 implants (OsseoSpeed ™ Profile TX implants) were included. Clinical assessments of soft tissue parameters were performed before implant placement, immediately after implant placement, at prosthetic delivery and at 6, 12 and 24 months after implant placement and marginal bone adaptation was examined. After an average time in situ of 28.7 ± 4.7 months (2.4 ± 0.4 years), the survival rate was 99.2%. Analysis of the peri-implant soft tissues during follow-up showed a slight but significant increase in peri-implant keratinized mucosa width after 2 years (P < 0.001). All patients with reduced peri-implant keratinized mucosa width of ≤ 2 mm at postoperative examination (n = 95) showed a pronounced and statistically significant increase in the peri-implant keratinized mucosa width over time (P < 0.001). After a mean follow-up of 20.7 ± 8 months (1.7 ± 0.7 years), mean inter-proximal marginal bone loss was 0.30 ± 0.6 mm, indicating high bone stability around the sloped implant neck. These results indicate that sloped configurated implants have a high survival rate after 2 years in function. The sloped implant shoulder configuration helps to support the hard and soft tissue around the implant neck and supports the regain of a physiological peri-implant keratinized mucosa in patients with compromised peri-implant soft tissue conditions (Clinicaltrials.gov: NCT01400321). © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Gehrke, Peter; Lobert, Markus; Dhom, Günter
2008-01-01
The pink esthetic score (PES) evaluates the esthetic outcome of soft tissue around implant-supported single crowns in the anterior zone by awarding seven points for the mesial and distal papilla, soft-tissue level, soft-tissue contour, soft-tissue color, soft-tissue texture, and alveolar process deficiency. The aim of this study was to measure the reproducibility of the PES and assess the influence exerted by the examiner's degree of dental specialization. Fifteen examiners (three general dentists, three oral maxillofacial surgeons, three orthodontists, three postgraduate students in implant dentistry, and three lay people) applied the PES to 30 implant-supported single restorations twice at an interval of 4 weeks. Using a 0-1-2 scoring system, 0 being the lowest, 2 being the highest value, the maximum achievable PES was 14. At the second assessment, the photographs were scored in reverse order. Differences between the two assessments were evaluated with the Spearman's rank correlation coefficient (R). The Wilcoxon signed-rank test was used for comparisons of differences between the ratings. A significance level of p < 0.05 was chosen for both tests. Observer results indicated that the agreement between the first and second rating for all occupational groups was 70.5%, with a broad correlation between the two ratings and a high statistical significance (Spearman's R = 0.58, p = 0; Wilcoxon T = 163,182, Z = 3.383599, p = 0.000716). The most agreement between the first and second rating was obtained by orthodontists with 73.5% (R = 0.67), and the least by lay people 65.9% (R = 0.50). Very poor and very esthetic restorations showed the smallest deviations. Orthodontists were found to have assigned significantly poorer ratings than any other group. The assessment of postgraduate students and laypersons were the most favorable. The PES allows for a more objective appraisal of the esthetic short- and long-term results of various surgical and prosthetic implant procedures. It reproducibly evaluates the peri-implant soft tissue around single-implant restorations and results in good intra-examiner agreement. However, an effect of observer specialization on rating soft-tissue esthetics can be shown.
Guarnieri, Renzo; Belleggia, Fabrizio; Grande, Maurizio
2016-02-01
To compare peri-implant marginal bone loss, soft tissue response, and esthetics following single immediate implant treatment (IIT) and delayed implant treatment (DIT) in the esthetic zone of the maxilla in well-selected patients. Adequate bone volume and ideal soft tissue level/contour were considered requirements for implant therapy, with additional prerequisites for IIT of residual alveolar bone wall integrity and a thick gingival biotype. IIT included immediate placement and provisionalization, while DIT included extraction socket preservation followed by implant placement and provisionalization 4 months later. Cortical bone levels and peri-implant mucosal conditions were evaluated at regular intervals. The esthetic outcome was objectively rated after 3 years using the pink esthetic score (PES) and white esthetic score (WES). Twelve patients received an immediate Laser-Lok® implant, and 13 patients received a delayed Laser-Lok® implant. No significant differences were found between the study groups regarding survival rate (100%). The mean bone level from the implant/abutment interface was 0.35 ± 0.18 mm for IIT and 0.42 ± 0.21 mm for DIT after 3 years (p > 0.05). Mesial and distal papillae remained stable over time in DIT. A tendency for regrowth of mesial and distal papillae was found following IIT (p < 0.05). Midfacial soft tissues remained stable over time following DIT and IIT. Within the limitations of this study (e.g., small sample size, short follow-up duration), the results suggest that regarding success rate, hard/soft tissue responses, and esthetics, DIT and IIT with single Laser-Lok® implants in the anterior maxilla are comparable and predictable options for well-selected patients. © 2015 by the American College of Prosthodontists.
Characterization of Cement Particles Found in Peri-implantitis-Affected Human Biopsy Specimens.
Burbano, Maria; Wilson, Thomas G; Valderrama, Pilar; Blansett, Jonathan; Wadhwani, Chandur P K; Choudhary, Pankaj K; Rodriguez, Lucas C; Rodrigues, Danieli C
2015-01-01
Peri-implantitis is a disease characterized by soft tissue inflammation and continued loss of supporting bone, which can result in implant failure. Peri-implantitis is a multifactorial disease, and one of its triggering factors may be the presence of excess cement in the soft tissues surrounding an implant. This descriptive study evaluated the composition of foreign particles from 36 human biopsy specimens with 19 specimens selected for analysis. The biopsy specimens were obtained from soft tissues affected by peri-implantitis around cement-retained implant crowns and compared with the elemental composition of commercial luting cement. Nineteen biopsy specimens were chosen for the comparison, and five test cements (TempBond, Telio, Premier Implant Cement, Intermediate Restorative Material, and Relyx) were analyzed using scanning electron microscopy equipped with energy dispersive x-ray spectroscopy. This enabled the identification of the chemical composition of foreign particles embedded in the tissue specimens and the composition of the five cements. Statistical analysis was conducted using classification trees to pair the particles present in each specimen with the known cements. The particles in each biopsy specimen could be associated with one of the commercial cements with a level of probability ranging between .79 and 1. TempBond particles were found in one biopsy specimen, Telio particles in seven, Premier Implant Cement particles in four, Relyx particles in four, and Intermediate Restorative Material particles in three. Particles found in human soft tissue biopsy specimens around implants affected by peri-implant disease were associated with five commercially available dental cements.
Mehl, Christian; Gassling, Volker; Schultz-Langerhans, Stephan; Açil, Yahya; Bähr, Telse; Wiltfang, Jörg; Kern, Matthias
The main aim of this study was to evaluate the influence of four different abutment materials and the adhesive joint of two-piece abutments on the cervical implant bone and soft tissue. Sixty-four titanium implants (Camlog Conelog; 4.3 ± 9 mm) were placed bone level into the edentulous arches of four minipigs. Four different types of abutments were placed at implant exposure: zirconium dioxide, lithium disilicate, and titanium bonded to a titanium luting base with resin cement; one-piece titanium abutments served as the control. The animals were sacrificed 6 months after implant exposure, and the bone-to-implant contact (BIC) area, sulcus depth, the length of the junctional epithelium and the connective tissue, the biologic width, and first cervical BIC-implant shoulder distance were measured using histomorphometry and light and fluorescence microscopy. Overall, 14 implants were lost (22%). At exposure, the implant shoulder-bone distance was 0.6 ± 0.7 mm. Six months later, the bone loss was 2.1 ± 1.2 mm measured histomorphometrically. There was a significant difference between the two measurements (P ≤ .0001). No significant influence could be found between any of the abutment materials with regard to bone loss or soft tissue anatomy (P > .05), with the exception of zirconium dioxide and onepiece titanium abutments when measuring the length of the junctional epithelium (P ≤ .01). The maxilla provided significantly more soft tissue and less bone loss compared with the mandible (P ≤ .02). All tested abutment materials and techniques seem to be comparable with regard to soft tissue properties and the cervical bone level.
Migliorati, Marco; Amorfini, Leonardo; Signori, Alessio; Biavati, Armando Silvestrini; Benedicenti, Stefano
2015-10-01
The aesthetic outcome of an implant-supported restoration is first of all dependent on the soft tissue volume. Because the labial bone plate resorbs in every direction after tooth extraction, even when an implant is placed immediately, most patients end up with compromised aesthetics. In this parallel-designed, randomized clinical trial, participants were randomly assigned to the test group (immediate load post-extractive implant treated with subepithelial connective tissue graft placed using the tunnel technique in the labial area) and control group (immediate load post-extractive implant treated without raising a flap) with an allocation ratio of 1:1. Both groups received deproteinized bovine bone mineral. Patients were observed at baseline, crown insertion, 1-year follow-up, and 2-year follow-up. Clinical, radiological and aesthetic parameters were recorded to assess primary treatment outcomes. A random permuted block system was blindly generated ensuring uniformity of the patient allocation during the trial by randomly distributing three participants to the test and three participants to the control group every six treated patients. At the 2-year examination, all 47 implants were successfully integrated, demonstrating stability and healthy peri-implant soft tissues as documented by standard clinical parameters. The results showed a soft tissue remodeling of -10% in thickness and -18% in highness in the non-grafted group, whereas in the grafted group there was a gain of 35% in thickness and a slight reduction of -11% in highness. Test group reported an increase of aesthetic result (mean pink aesthetic score [PES] 8) compared with control group (mean PES 6.65). This prospective study demonstrates the effectiveness of placing a soft tissue graft at the time of immediate implant placement in the aesthetic zone. At the 2-year follow-up, test group revealed a better aesthetic outcomes and stable facial soft tissues compared with control group. © 2013 Wiley Periodicals, Inc.
Immediate provisional restoration of a single-tooth implant in the esthetic zone: a case report.
Fu, Po-Sung; Wu, Yi-Min; Tsai, Ching-Fang; Huang, Ta-Ko; Chen, Wen-Cheng; Hung, Chun-Cheng
2011-02-01
Immediate implant restoration of single implants may demonstrate a positive effect on peri-implant soft tissue. Placement of a provisional restoration following implant surgery can create soft tissue contours that resemble normal gingival topography before placement of the definitive prosthesis. This article describes a staged approach of the mandibular permanent right central incisor, which was congenital missing. The proper space for restoration of the missing incisor was created through orthodontic treatment. The scheduled implant site was reconstructed using autogenous bone harvested from the chin region. After a healing period of four months, an implant was installed with the connection of a fixed provisional crown to a prefabricated temporary abutment. The soft tissue around the implant healed according to the contours of the provisional restoration and the emergence profile was used to duplicate the definitive restoration. Peri-implant esthetics was achieved through the staged approach and immediate restoration of the implant. Copyright © 2011. Published by Elsevier B.V.
Wang, Qing-qing; Dai, Ruoxi; Cao, Chris Ying; Fang, Hui; Han, Min; Li, Quan-Li
2017-01-01
Objective This review aims to compare peri-implant tissue changes in terms of clinical and radiographic aspects of implant restoration protocol using one-time abutment to repeated abutment connection in platform switched implant. Method A structured search strategy was applied to three electronic databases, namely, Pubmed, Embase and Web of Science. Eight eligible studies, including seven randomised controlled studies and one controlled clinical study, were identified in accordance with inclusion/exclusion criteria. Outcome measures included peri-implant bone changes (mm), peri-implant soft tissue changes (mm), probing depth (mm) and postsurgical complications. Result Six studies were pooled for meta-analysis on bone tissue, three for soft tissue, two for probing depth and four for postsurgical complications. A total of 197 implants were placed in one-time abutment group, whereas 214 implants were included in repeated abutment group. The implant systems included Global implants, Ankylos, JDEvolution (JdentalCare), Straumann Bone level and Conelog-Screwline. One-time abutment group showed significantly better outcomes than repeated abutment group, as measured in the standardised differences in mean values (fixed- and random-effect model): vertical bone change (0.41, 3.23) in 6 months, (1.51, 14.81) in 12 months and (2.47, 2.47) in 3 years and soft tissue change (0.21, 0.23). No significant difference was observed in terms of probing depth and complications. Conclusion Our meta-analysis revealed that implant restoration protocol using one-time abutment is superior to repeated abutment for platform switched implant because of less bone resorption and soft tissue shifts in former. However, future randomised clinical trials should be conducted to further confirm these findings because of the small samples and the limited quality of the original research. PMID:29049323
Wang, Qing-Qing; Dai, Ruoxi; Cao, Chris Ying; Fang, Hui; Han, Min; Li, Quan-Li
2017-01-01
This review aims to compare peri-implant tissue changes in terms of clinical and radiographic aspects of implant restoration protocol using one-time abutment to repeated abutment connection in platform switched implant. A structured search strategy was applied to three electronic databases, namely, Pubmed, Embase and Web of Science. Eight eligible studies, including seven randomised controlled studies and one controlled clinical study, were identified in accordance with inclusion/exclusion criteria. Outcome measures included peri-implant bone changes (mm), peri-implant soft tissue changes (mm), probing depth (mm) and postsurgical complications. Six studies were pooled for meta-analysis on bone tissue, three for soft tissue, two for probing depth and four for postsurgical complications. A total of 197 implants were placed in one-time abutment group, whereas 214 implants were included in repeated abutment group. The implant systems included Global implants, Ankylos, JDEvolution (JdentalCare), Straumann Bone level and Conelog-Screwline. One-time abutment group showed significantly better outcomes than repeated abutment group, as measured in the standardised differences in mean values (fixed- and random-effect model): vertical bone change (0.41, 3.23) in 6 months, (1.51, 14.81) in 12 months and (2.47, 2.47) in 3 years and soft tissue change (0.21, 0.23). No significant difference was observed in terms of probing depth and complications. Our meta-analysis revealed that implant restoration protocol using one-time abutment is superior to repeated abutment for platform switched implant because of less bone resorption and soft tissue shifts in former. However, future randomised clinical trials should be conducted to further confirm these findings because of the small samples and the limited quality of the original research.
Evaluation of Soft Tissue Reaction to Corundum Ceramic Implants Infiltrated with Colloidal Silver.
Wnukiewicz, Witold; Rutowski, Roman; Zboromirska-Wnukiewicz, Beata; Reichert, Paweł; Gosk, Jerzy
2016-01-01
Corundum ceramic is a biomaterial used as a bone graft substitute. Silver is a well known antiseptic substance with many practical, clinical applications. The aim of this study was to estimate soft tissue (in vivo) reaction to a new kind of ceramic implants. In our experiment, we examined the soft tissue reaction after implantation of corundum ceramic infiltrated with colloidal silver in the back muscles of 18 Wistar rats. The use of colloidal silver as a coating for the implant was designed to protect it against colonization by bacteria and the formation of bacterial biofilm. In our study, based on the experimental method, we performed implantation operations on 18 Wistar rats. We implanted 18 modified ceramic implants and, as a control group, 18 unmodified implants. As a follow up, we observed the animals operated upon, and did postoperative, autopsy and histopathological examinations 14, 30, 90 and 180 days after implantation. We didn't observe any pathological reactions and significant differences between the soft tissue reaction to the modified implants and the control group. Lack of pathological reaction to the modified implants in the living organism is the proof of their biocompatibility. This is, of course, the first step on the long path to introduce a new kind of biocompatible ceramic implant with antiseptic cottage. Our experiment has an only introductory character and we plan to perform other, more specific, tests of this new kind of implant.
Dahlin, C; Simion, M; Hatano, N
2010-12-01
In the present prospective study, bone augmentation by guided bone regeneration (GBR) in combination with bovine hydroxyapatite (BHA) as filling material was evaluated with regard to soft and hard tissue stability over time. Implant survival, radiologic bone level (marginal bone level [MBL]), and clinical soft tissue parameters (marginal soft tissue level [MSTL]) were observed. Twenty patients received a total of 41 implants (Brånemark System, Nobel Biocare, Göteborg, Sweden) in conjunction with GBR treatment. The end point of the study was after 5 years following implant placement. The cumulative implant survival rate was 97.5% corresponding to one implant failure. The radiologic evaluation of the MBL demonstrated a crestal bone height above the level of the fixture head. The bone height decreased from -3.51 to -2.38 mm (p < .001). The MSTL was -1.52 mm at baseline and -1.15 mm at the 5-year follow-up (p < .04) demonstrating a stable submucosal crown margin throughout the study period. GBR treatment in combination with a xenogeneic filling material (BHA) is a viable treatment option in order to maintain stable hard and soft tissue levels in conjunction with augmentative procedure related to oral implant treatment. © 2009, Copyright the Authors. Journal Compilation © 2010, Wiley Periodicals, Inc.
Timing of soft tissue management around dental implants: a suggested protocol.
Kadkhodazadeh, Mahdi; Amid, Reza; Kermani, Mehdi Ekhlasmand; Mirakhori, Mahdieh; Hosseinpour, Sepanta
2017-01-01
Survival of dental implants depends on several factors; soft tissue (ST) management around dental implants is one of the foremost. Several studies have suggested techniques for ST management around dental implants, but none of them has discussed a suitable timetable for this process. This study aimed to review published articles related to the timing of ST management around dental implants and suggest a customized treatment protocol. A search of the PubMed database was conducted; the search was limited to English-language articles published from January 1995 to July 2015 with available full texts. Only in vivo studies and clinical trials in relation to the terms soft tissue management, management timing, keratinized mucosa, free gingival graft, connective tissue graft, soft tissue, augmentation, and dental implant were included. A total of 492 articles were reviewed, and eventually 42 articles were thoroughly evaluated. Those with treatment protocols in terms of the timing of ST grafting were selected and classified. ST management around dental implants may be done prior to the surgical phase, after the surgical phase, before loading, or even after loading. A thick gingival biotype is more suitable for implant placement, providing more favorable esthetic results. A treatment plan should be based on individual patient needs as well as the knowledge and experience of the clinician. The width and thickness of keratinized tissues, the need for bone management, and local risk factors that influence esthetic results determine the appropriate time for ST augmentation procedures.
Reliability of implant surgical guides based on soft-tissue models.
Maney, Pooja; Simmons, David E; Palaiologou, Archontia; Kee, Edwin
2012-12-01
The purpose of this study was to determine the accuracy of implant surgical guides fabricated on diagnostic casts. Guides were fabricated with radiopaque rods representing implant positions. Cone beam computerized tomograms were taken with guides in place. Accuracy was evaluated using software to simulate implant placement. Twenty-two sites (47%) were considered accurate (13 of 24 maxillary and 9 of 23 mandibular sites). Soft-tissue models do not always provide sufficient accuracy for fabricating implant surgical guides.
Cosyn, Jan; De Rouck, Tim
2009-10-01
The aim of this study was to compare crown and soft tissue dimensions of single-tooth implant restorations following early implant placement and guided bone regeneration (GBR) with contralateral non-restored teeth. Twenty-seven patients treated by one and the same surgeon and prosthodontist to restore a single-tooth gap with a class I bone defect in the premaxilla by means of an implant-supported restoration were reviewed. Patients were examined at least 6 months following placement of the crown. All implants had been inserted 6-8 weeks following tooth extraction in conjunction with GBR. At evaluation, crown dimensions, soft tissue dimensions, clinical conditions and patients' aesthetic satisfaction were assessed by one clinician who had not been involved in the treatment. Implant-supported crowns were not significantly longer than contralateral teeth and midfacial soft tissues showed comparable levels after on average 21 months of function. Our data also indicated significant papilla loss especially at the distal aspect of the implants. As the patient's aesthetic appreciation was favourable in 88% of the cases, this appeared to be of trivial importance. Favourable aesthetics may be achieved for single-tooth implant restorations following early implant placement and GBR. The impact of the latter on papilla levels, however, remains to be determined in longitudinal studies.
Gu, Ying-Xin; Shi, Jun-Yu; Zhuang, Long-Fei; Qiao, Shi-Chong; Xu, You-You; Lai, Hong-Chang
2015-08-01
The aim of this prospective study was to assess the esthetic outcome and alterations of peri-implant soft tissue using tissue-level implants. Furthermore, the influencing factors, including grafting and gingival biotype, of esthetic outcome of peri-implant soft tissue were also evaluated. Of 38 patients with single missing anterior tooth in maxilla were treated with a Straumann (®) Standard Plus SLA implant. Bone augmentation was performed in 24 patients. Follow-up was conducted at 12 and 24 months after definitive crowns placement. Esthetic outcome using the pink esthetic score/white esthetic score (PES/WES) and clinical parameters were evaluated. The mean PES/WES value at baseline, 1-year, and 2-year examination was 13.79, 14.87, and 14.96. Significant improvement was found between baseline and 1-year examination (P < 0.01). And the improvement between 1-year and 2-year examination was not significant (P = 0.40). The mean PES changing value in patients with thick biotype was significantly higher than those with thin biotype at 2-year after definitive crowns placement (P = 0.03). Graft procedure had an unfavorable effect on mean PES value both at baseline and at follow-up (P < 0.01). No implants were lost at 2-year examination. Three patients experienced peri-implant infection. No significant difference was found with the passage of time in modified plaque index (mPI), probing pocket depth (PPD), and modified bleeding index (mBI). According to the present prospective clinical study, it can be concluded that it is feasible to use tissue-level implant to support single crowns in esthetic area. Favorable short-term esthetic outcome and stability of soft tissue around single implant crowns can be expected in patients with or without graft. However, graft procedures might have an unfavorable effect on the esthetic outcome. Gingival biotype can be considered as prognostic factor for esthetic outcome. RCTs with long-term follow-up are needed to provide evidence for the long-term stability of peri-implant soft tissue using tissue-level implant systems. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Mardinger, Ofer; Chaushu, Gavriel; Ghelfan, Oded; Nissan, Joseph
2009-06-01
The normal bone resorption after tooth extraction can be significantly aggravated in the case of pre-existing severe bone loss and chronic infection. Bone augmentation procedures have been proposed, but they require adequate closure of soft tissues. We propose the use of intrasocket reactive tissue to cover extraction sites augmented by bovine bone mineral graft to promote the success of the graft procedure. The study included 24 patients with severe bone loss and chronic pathology in 27 sites. The intrasocket reactive soft tissue was elevated from the bony walls in a subperiosteal plane. Porous bovine or allograft bone mineral was placed in the extraction site without membranes, and the intrasocket reactive soft tissue was sutured over the grafting material to seal the coronal portion of the socket. Twenty-seven implants were placed 6 months after bone augmentation. Healing progressed uneventfully. Postoperative morbidity was minimal. There was no leakage or infection of the grafting material. The mean time to implant placement was 7.8 months. Supplemental augmentation was not needed. There were no implant failures. Follow-up ranged from 6 to 36 months (mean, 15 months). All implants were rehabilitated with fixed prostheses. Intrasocket reactive soft tissue can be used predictably to obtain primary closure of augmented extraction sites with severe bone loss with minimal postoperative morbidity.
Injectable fillers: review of material and properties.
Attenello, Natalie Huang; Maas, Corey S
2015-02-01
With an increasing understanding of the aging process and the rapidly growing interest in minimally invasive treatments, injectable facial fillers have changed the perspective for the treatment and rejuvenation of the aging face. Other than autologous fat and certain preformed implants, the collagen family products were the only Food and Drug Administration approved soft tissue fillers. But the overwhelming interest in soft tissue fillers had led to the increase in research and development of other products including bioengineered nonpermanent implants and permanent alloplastic implants. As multiple injectable soft tissue fillers and biostimulators are continuously becoming available, it is important to understand the biophysical properties inherent in each, as these constitute the clinical characteristics of the product. This article will review the materials and properties of the currently available soft tissue fillers: hyaluronic acid, calcium hydroxylapatite, poly-l-lactic acid, polymethylmethacrylate, and autologous fat (and aspirated tissue including stem cells). Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Linkevicius, Tomas; Vaitelis, Julius
2015-09-01
The objective of this review was to analyze research with regard to the effect of zirconia or titanium as abutment material on soft peri-implant tissues. Clinical studies were selected via electronic and hand searches in English language journals until December 1, 2014. Only randomized clinical trials (RCTs) and prospective controlled clinical trials (CCTs) showing direct comparison between zirconia (Zr) and titanium (Ti) abutments in the same patient were considered. The outcome measures were (1) soft tissue color, (2) soft tissue recession, (3) peri-implant probing, (4) bleeding on probing, (5) esthetic indexes, (6) patient-reported outcome, (7) marginal bone level, and (8) biological complications. Nine relevant studies (11 papers) were identified: 4 RCTs and 5 CCTs. Due to heterogeneity in the study design, statistical methods, and reported results, a meta-analysis of the data was feasible only for soft tissue color. The outcome was found to be significantly superior for Zr abutments. For the other outcome measures, a qualitative analysis of the selected articles was performed. The studies did not show any statistically significant differences between Zr and Ti abutments on soft tissue recession, probing depths, bleeding on probing, marginal bone level, and patient-reported outcome. One study reported significantly higher pink esthetic score (PES) scores at Zr implants with Zr abutments, compared to metal implants and Ti abutments. Overall, the research does not support any obvious advantage of Ti or Zr abutments over each other. However, there is a significant tendency in Zr abutments evoking better color response of peri-implant mucosa and superior esthetic outcome measured by PES score. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Khzam, Nabil; Arora, Himanshu; Kim, Paul; Fisher, Anthony; Mattheos, Nikos; Ivanovski, Saso
2015-12-01
The aim of this review is to assess the outcome of single-tooth immediate implant placement and restoration (IPR) in the maxillary anterior region, with a particular emphasis on soft tissue and esthetic outcomes. An electronic search in Medline, EBSCOhost, and Ovid (PubMed) was performed to identify studies that reported on soft tissue outcomes following immediate placement and restoration of implants in the maxillary esthetic region with a mean follow-up of ≥1 year. Nineteen studies on single implants inserted immediately into fresh extraction sockets and provisionally restored in the maxillary esthetic region were included. Soft tissue changes were found to be acceptable, with most studies reporting mean gingival recession of 0.27 ± 0.38 mm and mean papillary height loss of 0.23 ± 0.27 mm after follow-up of ≥1 year. Advanced buccal recession (>1 mm) occurred in 11% of cases. Long-term follow-up studies (>2 years) reported that the interdental papillae, in particular, showed a tendency to rebound over time. The few studies that reported on patient-centered outcomes showed a high level of patient satisfaction with the outcomes of IPR treatment. The IPR protocol resulted in generally acceptable soft tissue and esthetic outcomes, with suboptimal results reported in ≈11% of low-risk cases. Factors such as preoperative tissue biotype or use of a flap or connective tissue graft did not significantly influence soft tissue and esthetic outcomes. Long-term prospective controlled clinical trials are necessary to identify factors that may influence the esthetic outcomes associated with IPR.
The Dermal Apron Technique for Immediate Implant Socket Management: A Novel Technique.
Levin, Barry P
2016-01-01
With immediate implant placement and provisionalization (IIP) in the esthetic zone, measures to counter hard and soft tissue loss are frequently necessary. To reduce the morbidity associated with bone and connective tissue procurement, various exogenous materials are utilized. The "Dermal Apron Technique" presented in this article demonstrates the use of a composite bone particulate (allograft/xenograft) plus a dermal allograft, adapted around screw-retained temporary crowns and secured within a subperiosteal pouch. The purpose is to augment the thickness of peri-implant mucosa for the purpose of preserving ridge dimensions and preventing mucosal recession. Controlled studies are required to further support its use. Clinical significance: Soft tissue health and harmony are critical for successful implant therapy in the esthetic regions of the dentition. Often, autogenous soft tissue grafts are used to augment peri-implant soft tissues. The Dermal Apron Technique is a method, that in specific situations, obviates the need for autogenous grafting. This reduces treatment time and morbidity associated with procurement of these grafts. The Dermal Apron Technique is used simultaneous with immediate placement and provisionalization and can improve long-term esthetic outcomes for patients. © 2016 Wiley Periodicals, Inc.
Finne, Kaj; Rompen, Eric; Toljanic, Joseph
2007-06-01
A novel 1-piece implant purported to provide for stable tissue support, immediate function, and immediate placement in extraction sockets has been developed. Stabilization of the marginal bone level over time requires documentation. The aim of this study was to evaluate marginal bone level differences and soft tissue health between the 1- and 2-year follow-up of a 1-piece implant design. Eighty-two implants, restoring both single teeth and multiple edentulous situations, in 56 consecutively treated patients, were included. Marginal bone level was evaluated on radiographs made at implant insertion, 6-month follow-up, and annually thereafter. At 3-, 6-month, and 1-year follow-ups, presence of plaque and the soft tissue response were evaluated using plaque and bleeding on probing indexes. The papilla index was used to determine papilla size at implant insertion with the provisional restoration in place and at the insertion of the definitive restoration. The change over time in marginal bone level was analyzed with a 1-way analysis of variance (ANOVA) paired design with time as main effect (1 to 2 years) and subjects as block effect (alpha=.05). One implant failure occurred, resulting in a 98.8% cumulative survival rate (CSR) for the follow-up time of 2 years. The mean (SD) change in bone level between years 1 and 2 was 0.08 mm (1.19) (95% CI-0.30 to 0.46) (P=.68), demonstrating a stable marginal bone level. Normal implant mucosa was noted for approximately 90% of the sites at the 1-year follow-up. The mean (SD) papilla score at placement was 1.3 (0.66) and increased to 1.7 (0.67) at insertion of the definitive prosthesis. The stable marginal bone level and soft tissue health observed indicate that the 1-piece implant tested has the ability to preserve both hard and soft tissue. Based on the high implant survival rate and favorable tissue response, the 1-piece implant can be recommended for clinical use.
Effects of Thread Depth in the Neck Area on Peri-Implant Hard and Soft Tissues: An Animal Study.
Sun, Shan-Pao; Lee, Dong-Won; Yun, Jeong-Ho; Park, Kwang-Ho; Park, Kwang-Bum; Moon, Ik-Sang
2016-11-01
Implants with deep thread depth have been developed for the purpose of increasing total implant surface area. However, effects of implant thread depth remain controversial. The aim of this study is to examine effects of thread depth on peri-implant tissues in terms of bone-implant contact (BIC), bone-implant volume (BIV), and hard and soft tissue dimensions using comprehensive analyses, including microcomputed tomography (micro-CT). Five beagle dogs received experimental intramandibular implants 3 months after removal of their premolars and first molars (P 2 , P 3 , P 4 , and M 1 ). Two different types of implants were installed in each animal: deep threaded (DT) and shallow threaded (ST). Resonance frequency testing was performed on the day of implantation as well as 4 and 8 weeks after implantation. Intraoral radiography, micro-CT, and histomorphometry were used to evaluate peri-implant tissues 4 and 8 weeks after implantation. There were no significant differences in resonance frequency test results between the two groups. Although radiographic analysis showed no group differences, micro-CT (P = 0.01) and histomorphometry (P = 0.003) revealed the DT group had significantly lower BIC values than the ST group at 4 weeks. However, by 8 weeks, BIC values of the two groups did not differ significantly. No significant differences in BIV or soft tissue height were observed between the two groups at either time point. DT implants showed no benefits over ST implants when inserted in dog mandibles.
Zuiderveld, Elise G; Meijer, Henny J A; Vissink, Arjan; Raghoebar, Gerry M
2018-05-13
Soft tissue grafting to thicken the soft tissue around dental implants was proposed to ameliorate the esthetic outcome. Traditionally, connective tissue is used as a grafting material, but a xenogeneic collagen matrix was introduced as an alternative to reduce patient morbidity. Sixty patients randomly received either no graft (n = 20, NG group), a connective tissue graft (n = 20, CTG group) or a xenogeneic collagen matrix (n = 20, XCM group) when placing an implant in a preserved alveolar ridge. Changes in mid-buccal mucosal level (MBML) at one (T 1 ) and twelve (T 12 ) months after final implant crown placement were compared to the pre-extraction situation. Additionally, esthetics, marginal bone level, clinical peri-implant parameters and patient satisfaction were assessed. At T 12 , mean changes in MBML were -0.48±1.5 mm, -0.04±1.1 mm and -0.17±1.3 mm in the NG, CTG and XCM groups (p = 0.56), respectively. Regarding the other outcome variables, no significant inter-group differences were observed. Soft tissue grafting at single implant placement in preserved alveolar ridges does not result in a better esthetic outcome or in better peri-implant health and should not be considered as a standard procedure. This article is protected by copyright. All rights reserved. © 2018 American Academy of Periodontology.
Patient-specific polyetheretherketone facial implants in a computer-aided planning workflow.
Guevara-Rojas, Godoberto; Figl, Michael; Schicho, Kurt; Seemann, Rudolf; Traxler, Hannes; Vacariu, Apostolos; Carbon, Claus-Christian; Ewers, Rolf; Watzinger, Franz
2014-09-01
In the present study, we report an innovative workflow using polyetheretherketone (PEEK) patient-specific implants for esthetic corrections in the facial region through onlay grafting. The planning includes implant design according to virtual osteotomy and generation of a subtraction volume. The implant design was refined by stepwise changing the implant geometry according to soft tissue simulations. One patient was scanned using computed tomography. PEEK implants were interactively designed and manufactured using rapid prototyping techniques. Positioning intraoperatively was assisted by computer-aided navigation. Two months after surgery, a 3-dimensional surface model of the patient's face was generated using photogrammetry. Finally, the Hausdorff distance calculation was used to quantify the overall error, encompassing the failures in soft tissue simulation and implantation. The implant positioning process during surgery was satisfactory. The simulated soft tissue surface and the photogrammetry scan of the patient showed a high correspondence, especially where the skin covered the implants. The mean total error (Hausdorff distance) was 0.81 ± 1.00 mm (median 0.48, interquartile range 1.11). The spatial deviation remained less than 0.7 mm for the vast majority of points. The proposed workflow provides a complete computer-aided design, computer-aided manufacturing, and computer-aided surgery chain for implant design, allowing for soft tissue simulation, fabrication of patient-specific implants, and image-guided surgery to position the implants. Much of the surgical complexity resulting from osteotomies of the zygoma, chin, or mandibular angle might be transferred into the planning phase of patient-specific implants. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Immediate placement and restoration of dental implants in the esthetic region: clinical case series.
Khzam, Nabil; Mattheos, Nikos; Roberts, David; Bruce, William L; Ivanovski, Saso
2014-01-01
The objective of this study was to assess the hard and soft tissue changes following immediate placement and provisional restoration of single-tooth implants in the aesthetic zone. Thirteen patients with immediately placed and restored implants were included in this study. All participating patients underwent the same treatment strategy that involved removal of the failed tooth, flapless surgery, immediate implant placement, and connection of a screw-retained provisional restoration. Three months following implant placement, the temporary crowns were replaced by the definitive restorations. Implant survival rates, and hard and soft tissue changes were measured using periapical X-rays and photographs. The range of the observation period was between 12 and 37 months with a mean period of 23.2 ± 7.6 months. At the time of follow-up, all implants were present with no complications. Radiographic evaluation revealed a mean mesial bone gain of 1.20 ± 1.01 mm and a mean distal bone gain of 0.80 ± 1.14 mm, which reached statistical significance. The mean mid-buccal recession was 0.20 ± 0.78 mm, whereas the mesial and distal papillae height loss was 0.50 ± 1.26 mm and 0.30 ± 0.82 mm, respectively. The changes in the soft tissues did not reach statistical significance. Notwithstanding the limitation of a small sample size, this study shows that immediate implant placement and provisional restoration in the maxillary aesthetic zone can result in favorable treatment outcomes with regards to soft and hard tissues changes over a follow-up period of 23.2 ± 7.6 months. Most clinical trials investigating immediate implant placement and immediate restoration in the maxillary anterior zone have focused on implant survival and implant success, with particular emphasis on radiographically assessed hard tissues changes. However, this study assesses the soft tissue changes associated with this procedure, which is an important area of study given the esthetic demands of implant therapy in the maxillary anterior region. © 2013 Wiley Periodicals, Inc.
Stiller, Michael; Mengel, Rainer; Becher, Sebastian; Brinkmann, Bernhard; Peleska, Barbara; Kluk, Esther
2015-12-01
This retrospective study evaluated soft-tissue grafting as a surgical treatment option for peri-implantitis in case of unsuitable basic skeletal morphology of the alveolar bone and lack of keratinized mucosa. Twenty-eight patients (21 females, 7 males, at a mean age 59.4 years) were included with a total of 54 implants. All implants showed peri-implantitis and attached keratinized buccal mucosa of ≤2 mm. A surgical procedure of soft-tissue grafting (STG) was made by inserting an inlay and inlay-onlay transplant. Clinical investigations were made prior to the STG (baseline) and after 9-180 months (Ø 43 months) including the following parameters: soft-tissue biotype, skeletal basic morphology of the alveolar bone, width of the peri-implant keratinized mucosa (KM), mobility of the KM, pocket probing depth (PPD), and bleeding on probing (BOP). Nearly all patients showed a thin soft-tissue biotype. The analysis of the skeletal basic morphology of the alveolar bone revealed a narrow apical base in 18 patients, middle base in 7 patients, and broad base in 3 patients. Width of the KM increased significantly (p < 0.01) from 0.4 ± 0,5 mm to 4.3 ± 1.5 mm after STG and PPD was significantly (p < 0,01) reduced from 6.3 ± 2,3 mm to 4.1 ± 1.9 mm. A significant reduction (p < 0.01) in BOP was recorded. All patients reported a clinical improvement of the inflammatory symptoms at follow-up. The results of this study showed that the STG can be applied successfully as a surgical treatment of peri-implantitis. It remains unclear whether soft-tissue biotype or the skeletal basic morphology of the alveolar bone affects the outcome of this surgical treatment.
Thoma, Daniel S; Naenni, Nadja; Benic, Goran I; Hämmerle, Christoph H F; Jung, Ronald E
2017-02-01
The aim of this study was to test whether or not soft tissue augmentation with a collagen matrix (VCMX) leads to a similar increase in ridge width around dental implants compared to the use of an autogenous subepithelial connective tissue graft (SCTG). In 12 dogs, immediate dental implants were placed with simultaneous guided bone regeneration. Three months later, soft tissue volume augmentation was performed by randomly allocating three treatment modalities to these sites [VCMX, SCTG, sham-operated group (control)]. Dogs were sacrificed at 1 (n = 4), 2 (n = 4) or 6 months (n = 4). Descriptive histology and histomorphometric measurements for soft tissue thickness were performed on non-decalcified sections. The horizontal soft tissue thickness was maximal at the most coronal level (alveolar crest) at 1 month (VCMX: 2.1 ± 1.6 mm; SCTG: 2.5 ± 1.7 mm; p = 0.877) and decreased until 6 months. At 6 months, the greatest mucosal thickness was at a level 3.5 mm below the crest (VCMX: 0.8 ± 0.3 mm; SCTG: 0.7 ± 0.2 mm) (p = 0.754). Control sites revealed no relevant soft tissue augmentation at any level and any time-point. Tissue integration for VCMX and SCTG were favourable with minimal inflammatory reactions. Soft tissue volume augmentation at implant sites was obtained to a similar extent using VCMX and SCTG up to 2 months. Thereafter, degradation and remodelling processes were enhanced leading to a minimal increase in soft tissue thickness at 6 months for VCMX and SCTG. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Histologic and morphologic evaluation of explanted bone anchors from bone-anchored hearing aids.
Mlynski, Robert; Goldberg, Eva; Ebmeyer, Joerg; Scheich, Matthias; Gattenlöhner, Stefan; Schwager, Konrad; Hagen, Rudolf; Shehata-Dieler, Wafaa
2009-05-01
Bone-anchored hearing aids are a standard option in rehabilitation of patients with conductive or mixed hearing loss, and also CROS fitting. However, the skin-penetrating bone anchor repeatedly gives reason for discussion about the risk of infection of surrounding tissues as a major cause of malfunction. In the present study, explanted bone anchors with surrounding bone and soft tissue were examined and compared with the morphology of lost implants. The anchors originated from five patients. Two needed explantation due to deafness with the need of cochlea implantation. A third patient underwent explantation due to meningeal irritation by the bone anchor. Another patient lost the implant due to mechanical stress shortly after implantation. The last implant was lost in a child without apparent reason. All implants were clinically free of infection and had been stable for a median implantation period of 12 months. During the explantation procedure, the fixtures were recovered together with the attached soft tissue and bone. The specimens were examined by light microscopy or scanning electron microscopy (SEM). Sectioning for light microscopy was performed with a diamond-coated saw microtome. Histopathologic examination of the surrounding skin and subcutaneous soft tissue showed slight inflammation in one case only. The bone was regularly vital, presenting no signs of inflammation. The threads of the fixtures were filled with bone, with particularly strong attachment to the flank of traction. The SEM investigation exposed the ultrastructural interaction of bone with the implant surface. Filiform- and podocyte-like processes of osteocytes attach to the implant; lost implants did not reflect these features. Implant integration involves both osseointegration as well as soft tissue integration. Titanium oxide as the active implant surface promotes this integration even in unstable implants. The morphologic analysis exposed structural areas of the implant with weak bone-to-metal contact. Optimized implant design with modified surface and threads may additionally improve osseointegration of hearing aid bone anchors.
Rhalmi, S; Odin, M; Assad, M; Tabrizian, M; Rivard, C H; Yahia, L H
1999-01-01
Porous nickel-titanium (NiTi) alloys have demonstrated bone attachment as well as tissue ingrowth in the past. However, very few studies have compared porous NiTi soft and hard tissue reactions, and in vitro cell response. We therefore have evaluated the general muscle and bone reaction to porous nickel-titanium. The latter material was implanted in rabbit tibias and back muscle, and assessed after three, six and twelve weeks of implantation. Porous NiTi specimens did not cause any adverse effect regardless of both implantation site and post-surgery recovery time. Muscle tissue exhibited thin tightly adherent fibrous capsules with fibers penetrating into implant pores. We observed that attachment strength of the soft tissue to the porous implant seemed to increase with post-implantation time. Bone tissue demonstrated good healing of the osteotomy. There was bone remodeling characterized by osteoclastic and osteoblastic activity in the cortex. This general good in vivo biocompatibility with muscle and bone tissue corresponded very well with the in vitro cell culture results we obtained. Fibroblasts seeded on porous nickel-titanium sheets managed to grow into the pores and all around specimen edges showing an another interesting cytocompatibility behavior. These results indicate good biocompatibility acceptance of porous nickel-titanium and are very promising towards eventual NiTi medical device approbation.
Esposito, Marco; Maghaireh, Hassan; Grusovin, Maria Gabriella; Ziounas, Ioannis; Worthington, Helen V
2012-01-01
This review is based on a Cochrane systematic review entitled 'Interventions for replacing missing teeth: management of soft tissues for dental implants' published in The Cochrane Library (see http:// www.cochrane.org/ for information). Cochrane systematic reviews are regularly updated to include new research, and in response to comments and criticisms from readers. If you wish to comment on this review, please send your comments to the Cochrane website or to Marco Esposito. The Cochrane Library should be consulted for the most recent version of the review. The results of a Cochrane review can be interpreted differently, depending on people's perspectives and circumstances. Please consider the conclusions presented carefully. They are the opinions of the review authors, and are not necessarily shared by the Cochrane Collaboration. To evaluate whether flapless procedures are beneficial for patients and which is the ideal flap design, whether soft tissue correction/augmentation techniques are beneficial for patients and which are the best techniques, whether techniques to increase the peri-implant keratinised mucosa are beneficial for patients and which are the best techniques, and which are the best suturing techniques/ materials. The Cochrane Oral Health Group's Trials Register, CENTRAL, MEDLINE and EMBASE were searched up to the 9th of June 2011 for randomised controlled trials (RCTs) of rootform osseointegrated dental implants, with a follow-up of at least 6 months after function, comparing various techniques to handle soft tissues in relation to dental implants. Primary outcome measures were prosthetic failures, implant failures and biological complications. Screening of eligible studies, assessment of the methodological quality of the trials and data extraction were conducted at least in duplicate and independently by two or more review authors. The statistical unit was the patient and not the prosthesis, the procedure or the implant. RESULTS were expressed using risk ratios for dichotomous outcomes and mean differences for continuous outcomes with 95% confidence intervals (CI). Seventeen potentially eligible RCTs were identified but only six trials with 138 patients in total could be included. The following techniques were compared in the six included studies: flapless placement of dental implants versus conventional flap elevation (2 trials, 56 patients), crestal versus vestibular incisions (1 trial, 10 patients), Erbium:YAG laser versus flap elevation at the second-stage surgery for implant exposure (1 trial, 20 patients), whether a connective tissue graft at implant placement could be effective in augmenting peri-implant tissues (1 split-mouth trial, 10 patients), and autograft versus an animal-derived collagen matrix to increase the height of the keratinised mucosa (1 trial, 40 patients). On a patient rather than per implant basis, implants placed with a flapless technique and implant exposures performed with laser lead to statistically significantly less postoperative pain than flap elevation. Sites augmented with soft tissue connective grafts had better aesthetics and thicker tissues. Both palatal autografts or the use of a porcine-derived collagen matrix are effective in increasing the height of keratinised mucosa at the cost of a 0.5 mm recession of peri-implant soft tissues. There were no other statistically significant differences for any of the remaining analyses. There is limited weak evidence suggesting that flapless implant placement is feasible and has been shown to reduce patient postoperative discomfort in adequately selected patients, that augmentation at implant sites with soft tissue grafts is effective in increasing soft tissue thickness and improving aesthetics, and that one technique to increase the height of keratinised mucosa using autografts or an animal-derived collagen matrix was able to achieve its goal but at the cost of a worsened aesthetic outcome (0.5 mm of recession). There is insufficient reliable evidence to provide recommendations on which is the ideal flap design, the best soft tissue augmentation technique, whether techniques to increase the width of keratinised/attached mucosa are beneficial to patients or not, and which are the best incision/suture techniques/materials. Properly designed and conducted RCTs, with at least 6 months of follow-up, are needed to provide reliable answers to these questions.
A 3-year multicenter study of marginal bone level and soft tissue health of a 1-piece implant.
Baer, Russell A; Shanaman, Richard; Clark, Paul K; Medley, Michael
2013-08-01
The study evaluated 1-piece implants in daily clinical situations. One-piece implants restoring both single teeth and partially edentulous sites were included. A single-stage procedure was used with immediate provisionalization within 24 hours after surgery. The definitive prosthesis was delivered within 6 months of implant insertion. One hundred fifteen implants have been placed in 84 patients at 4 centers. Two implants failed resulting in a cumulative survival rate of 98.3%. Normal periimplant mucosa and no visible plaque were observed in most of the implants. The soft tissue papilla scores improved considerably over time P < 0.001. Patient assessment improved significantly from implant insertion to the 3-year visit, P < 0.001. The mean bone level at implant insertion, 6-month, and 1-, 2-, and 3-year visits was 0.42, -0.58, -0.69, -0.80, and -0.66 mm, respectively. The mean change in bone level from implant insertion to 6 months and 1, 2, and 3 years was reported as -1.02, -1.12, -1.26, and -1.07 mm, respectively. The results indicate that this implant has the ability to preserve both hard and soft tissues' architecture.
Petrungaro, Paul S; Gonzalez, Santiago; Villegas, Carlos
2018-02-01
As dental implants become more popular for the treatment of partial and total edentulism and treatment of "terminal dentitions," techniques for the management of the atrophic posterior maxillae continue to evolve. Although dental implants carry a high success rate long term, attention must be given to the growing numbers of revisions or retreatment of cases that have had previous dental implant treatment and/or advanced bone replacement procedures that, due to either poor patient compliance, iatrogenic error, or poor quality of the pre-existing alveolar and/or soft tissues, have led to large osseous defects, possibly with deficient soft-tissue volume. In the posterior maxillae, where the poorest quality of bone in the oral cavity exists, achieving regeneration of the alveolar bone and adequate volume of soft tissue remains a complex procedure. This is made even more difficult when dealing with loss of dental implants previously placed, aggressive bone reduction required in various implant procedures, and/or residual sinus infections precluding proper closure of the oral wound margins. The purpose of this article is to outline a technique for the total closure of large oro-antral communications, with underlying osseous defects greater than 15 mm in width and 30 mm in length, for which multiple previous attempts at closure had failed, to achieve not only the reconstruction of adequate volume and quality of soft tissues in the area of the previous fistula, but also total regeneration of the osseous structures in the area of the large void.
Thoma, Daniel S; Buranawat, Borvornwut; Hämmerle, Christoph H F; Held, Ulrike; Jung, Ronald E
2014-04-01
To review the dental literature in terms of efficacy of soft tissue augmentation procedures around dental implants and in partially edentulous sites. A Medline search was performed for human studies augmenting keratinized mucosa (KM) and soft tissue volume around implants and in partially edentulous areas. Due to heterogeneity in between the studies, no meta-analyses could be performed. Nine (KM) and eleven (volume) studies met the inclusion criteria. An apically positioned flap/vestibuloplasty (APF/V) plus a graft material [free gingival graft (FGG)/subepithelial connective tissue graft (SCTG)/collagen matrix (CM)] resulted in an increase of keratinized tissue (1.4-3.3 mm). Statistically significantly better outcomes were obtained for APF/V plus FGG/SCTG compared with controls (APF/V alone; no treatment) (p < 0.05). For surgery time and patient morbidity, statistically significantly more favourable outcomes were reported for CM compared to SCTGs (p < 0.05) in two randomized controlled clinical trials (RCTs), even though rendering less keratinized tissue. SCTGs were the best-documented method for gain of soft tissue volume at implant sites and partially edentulous sites. Aesthetically at immediate implant sites, better papilla fill and higher marginal mucosal levels were obtained using SCTGs compared to non-grafted sites. An APF/V plus FGG/SCTG was the best-documented and most successful method to increase the width of KM. APF/V plus CM demonstrated less gain in KM, but also less patient morbidity and surgery time compared to APF/V plus SCTG based on two RCTs. Autogenous grafts (SCTG) rendered an increase in soft tissue thickness and better aesthetics compared to non-grafted sites. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Metal elements in tissue with dental peri-implantitis: a pilot study.
Fretwurst, Tobias; Buzanich, Guenter; Nahles, Susanne; Woelber, Johan Peter; Riesemeier, Heinrich; Nelson, Katja
2016-09-01
Dental peri-implantitis is characterized by a multifactorial etiology. The role of metal elements as an etiological factor for peri-implantitis is still unclear. The aim of this study was to investigate the incidence of metal elements in bone and mucosal tissues around dental Grade 4 CP titanium implants with signs of peri-implantitis in human patients. In this prospective pilot study, all patients were enrolled consecutively in two study centers. Bone and soft tissue samples of patients with peri-implantitis with indication for explantation were analyzed for the incidence of different elements (Ca, P, Ti, Fe) by means of synchrotron radiation X-ray fluorescence spectroscopy (SRXRF) and polarized light microscopy (PLM). The existence of macrophages and lymphocytes in the histologic specimens was analyzed. Biopsies of 12 patients (seven bone samples, five mucosal samples) were included and analyzed. In nine of the 12 samples (75%), the SRXRF examination revealed the existence of titanium (Ti) and an associated occurrence with Iron (Fe). Metal particles were detected in peri-implant soft tissue using PLM. In samples with increased titanium concentration, lymphocytes were detected, whereas M1 macrophages were predominantly seen in samples with metal particles. Titanium and Iron elements were found in soft and hard tissue biopsies retrieved from peri-implantitis sites. Further histologic and immunohistochemical studies need to clarify which specific immune reaction metal elements/particles induce in dental peri-implant tissue. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Changes in soft tissues around immediate full-arch rehabilitations: a prospective study.
Covani, U; Ricci, M; D'Ambrosio, N; Quaranta, A; Barone, A
2013-08-01
Nowadays, aesthetic appearance is receiving more and more attention from clinicians and patients. Therefore, it is of paramount importance for the surgeon to maintain or to improve the quality and the stability of the soft tissue-implant interface. The scientific literature supports the idea that the immediate placement and provisionalization of endosseus implants and abutments can indeed offer additional clinical control over the peri-implant tissue architecture. On this basis, this prospective study aims to evaluate the changes in soft tissues around immediately loaded dental implants in full-arch rehabilitations, over a period of 3 months. Fifteen subjects were treated for immediate full-arch rehabilitations. Following implant placement, provisional rehabilitations made of bisphenol-A-glycidyldimethacrylate (BIS-GMA) and resin were placed. All records were made using a periodontal probe. The facial soft-tissue level was measured evaluating the distance between the soft-tissue margin and the incisal edge of the crown. Moreover, papilla levels were measured at the mesial and distal sites from a reference line connecting the occlusal edge of the crowns. The average value at the mesial site was -0.035 mm (±1, median 0 mm), while at the midfacial site, it was 0 mm (±0.76, median 0 mm) and at the distal site, -0.05 mm (±0.92, median 0 mm). The plaque score index showed a reduction during the follow-up period. Our data indicate that no differences at the midfacial point were detectable over the observation period. This is in agreement with several studies; it is plausible that these results are linked to a correct position of the implant in the alveolar socket. Moreover, comparing our results with what has been reported by other authors, it is surprising that while other studies highlight that papilla loss at the mesial and distal aspect is an expected consequence of immediate implant restorations, our data do not show any changes. The explanation of these results remains unclear. Further studies are needed to support our data and to clarify what mechanisms are involved in the maintenance of soft tissue. © 2012 John Wiley & Sons A/S.
Thoma, Daniel S; Zeltner, Marco; Hilbe, Monika; Hämmerle, Christoph H F; Hüsler, Jürg; Jung, Ronald E
2016-10-01
To test whether or not the use of a collagen matrix (VCMX) results in short-term soft tissue volume increase at implant sites non-inferior to an autogenous subepithelial connective tissue graft (SCTG), and to evaluate safety and tissue integration of VCMX and SCTG. In 20 patients with a volume deficiency at single-tooth implant sites, soft tissue volume augmentation was performed randomly allocating VCMX or SCTG. Soft tissue thickness, patient-reported outcome measures (PROMs), and safety were assessed up to 90 days (FU-90). At FU-90 (abutment connection), tissue samples were obtained for histological analysis. Descriptive analysis was computed for both groups. Non-parametric tests were applied to test non-inferiority for the gain in soft tissue thickness at the occlusal site. Median soft tissue thickness increased between BL and FU-90 by 1.8 mm (Q1:0.5; Q3:2.0) (VCMX) (p = 0.018) and 0.5 mm (-1.0; 2.0) (SCTG) (p = 0.395) (occlusal) and by 1.0 mm (0.5; 2.0) (VCMX) (p = 0.074) and 1.5 mm (-2.0; 2.0) (SCTG) (p = 0.563) (buccal). Non-inferiority with a non-inferiority margin of 1 mm could be demonstrated (p = 0.020); the difference between the two group medians (1.3 mm) for occlusal sites indicated no relevant, but not significant superiority of VCMX versus SCTG (primary endpoint). Pain medication consumption and pain perceived were non-significantly higher in group SCTG up to day 3. Median physical pain (OHIP-14) at day 7 was 100% higher for SCTG than for VCMX. The histological analysis revealed well-integrated grafts. Soft tissue augmentation at implant sites resulted in a similar or higher soft tissue volume increase after 90 days for VCMX versus SCTG. PROMs did not reveal relevant differences between the two groups. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Ultrasoft microwire neural electrodes improve chronic tissue integration.
Du, Zhanhong Jeff; Kolarcik, Christi L; Kozai, Takashi D Y; Luebben, Silvia D; Sapp, Shawn A; Zheng, Xin Sally; Nabity, James A; Cui, X Tracy
2017-04-15
Chronically implanted neural multi-electrode arrays (MEA) are an essential technology for recording electrical signals from neurons and/or modulating neural activity through stimulation. However, current MEAs, regardless of the type, elicit an inflammatory response that ultimately leads to device failure. Traditionally, rigid materials like tungsten and silicon have been employed to interface with the relatively soft neural tissue. The large stiffness mismatch is thought to exacerbate the inflammatory response. In order to minimize the disparity between the device and the brain, we fabricated novel ultrasoft electrodes consisting of elastomers and conducting polymers with mechanical properties much more similar to those of brain tissue than previous neural implants. In this study, these ultrasoft microelectrodes were inserted and released using a stainless steel shuttle with polyethyleneglycol (PEG) glue. The implanted microwires showed functionality in acute neural stimulation. When implanted for 1 or 8weeks, the novel soft implants demonstrated significantly reduced inflammatory tissue response at week 8 compared to tungsten wires of similar dimension and surface chemistry. Furthermore, a higher degree of cell body distortion was found next to the tungsten implants compared to the polymer implants. Our results support the use of these novel ultrasoft electrodes for long term neural implants. One critical challenge to the translation of neural recording/stimulation electrode technology to clinically viable devices for brain computer interface (BCI) or deep brain stimulation (DBS) applications is the chronic degradation of device performance due to the inflammatory tissue reaction. While many hypothesize that soft and flexible devices elicit reduced inflammatory tissue responses, there has yet to be a rigorous comparison between soft and stiff implants. We have developed an ultra-soft microelectrode with Young's modulus lower than 1MPa, closely mimicking the brain tissue modulus. Here, we present a rigorous histological comparison of this novel ultrasoft electrode and conventional stiff electrode with the same size, shape and surface chemistry, implanted in rat brains for 1-week and 8-weeks. Significant improvement was observed for ultrasoft electrodes, including inflammatory tissue reaction, electrode-tissue integration as well as mechanical disturbance to nearby neurons. A full spectrum of new techniques were developed in this study, from insertion shuttle to in situ sectioning of the microelectrode to automated cell shape analysis, all of which should contribute new methods to the field. Finally, we showed the electrical functionality of the ultrasoft electrode, demonstrating the potential of flexible neural implant devices for future research and clinical use. Copyright © 2017. Published by Elsevier Ltd.
Implanted depleted uranium fragments cause soft tissue sarcomas in the muscles of rats.
Hahn, Fletcher F; Guilmette, Raymond A; Hoover, Mark D
2002-01-01
In this study, we determined the carcinogenicity of depleted uranium (DU) metal fragments containing 0.75% titanium in muscle tissues of rats. The results have important implications for the medical management of Gulf War veterans who were wounded with DU fragments and who retain fragments in their soft tissues. We compared the tissue reactions in rats to the carcinogenicity of a tantalum metal (Ta), as a negative foreign-body control, and to a colloidal suspension of radioactive thorium dioxide ((232)Th), Thorotrast, as a positive radioactive control. DU was surgically implanted in the thigh muscles of male Wistar rats as four squares (2.5 x 2.5 x 1.5 mm or 5.0 x 5.0 x 1.5 mm) or four pellets (2.0 x 1.0 mm diameter) per rat. Ta was similarly implanted as four squares (5.0 x 5.0 x 1.1 mm) per rat. Thorotrast was injected at two sites in the thigh muscles of each rat. Control rats had only a surgical implantation procedure. Each treatment group included 50 rats. A connective tissue capsule formed around the metal implants, but not around the Thorotrast. Radiographs demonstrated corrosion of the DU implants shortly after implantation. At later times, rarifactions in the radiographic profiles correlated with proliferative tissue responses. After lifetime observation, the incidence of soft tissue sarcomas increased significantly around the 5.0 x 5.0 mm squares of DU and the positive control, Thorotrast. A slightly increased incidence occurred in rats implanted with the 2.5 x 2.5 mm DU squares and with 5.0 x 5.0 mm squares of Ta. No tumors were seen in rats with 2.0 x 1.0 mm diameter DU pellets or in the surgical controls. These results indicate that DU fragments of sufficient size cause localized proliferative reactions and soft tissue sarcomas that can be detected with radiography in the muscles of rats. PMID:11781165
Long-term outcomes of bone augmentation on soft and hard-tissue stability: a systematic review.
Lutz, Rainer; Neukam, Friedrich W; Simion, Massimo; Schmitt, Christian M
2015-09-01
Peri-implant hard-tissue augmentation is a widely used clinical procedure. The present review aimed to analyse the current literature regarding medium- and long-term data concerning the stability of peri-implant tissues after hard-tissue augmentation prior or immediately with implant placement. An electronic literature search was performed using Medline (PubMed) databases detecting clinical studies focusing on hard- and soft-tissue stability around dental implants placed either in augmented alveolar ridges or simultaneously with peri-implant bone grafting. The search was limited to articles published between 1995 and December 2014, focusing on clinical studies with a prospective study design assessing peri-implant bone and soft tissue stability over time with a minimum follow-up of 12 months. Recent publications were also searched manually to find any relevant studies that might have been missed using the search criteria noted above. Thirty-seven articles met the inclusion criteria and were included in this systematic review. Since the outcome measures and methods, as well as types of grafts and implants used were so heterogeneous, the performance of meta-analysis was impossible. The highest level of evidence was achieved by randomized clinical trials. Different hard-tissue augmentation procedures seem to show stable peri-implant tissues, although, up to now, long-term stability of the augmented buccal bone is assessed by only few studies. Further research should concentrate on combining three-dimensional radiographic data with non-invasive methods as digital surface measuring techniques or ultrasound evaluation. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Firoozabadi, Reza; Kramer, Patricia A; Benirschke, Stephen K
2013-11-01
Although Kirschner wires are useful implants in many situations, migration of the wire and irritation of the surrounding soft tissues are common complications. Seven steps are described herein, which result in a Kirschner wire that is bent 180° angle, providing a smooth anchor into bone. Use of this technique produces implants that provide stable fixation with few soft tissue complications.
Angiogenic effects of borate glass microfibers in a rodent model.
Lin, Yinan; Brown, Roger F; Jung, Steven B; Day, Delbert E
2014-12-01
The primary objective of this research was to evaluate the use of bioactive borate-based glass microfibers for angiogenesis in soft tissue repair applications. The effect of these fibers on growth of capillaries and small blood vessels was compared to that of 45S5 silica glass microfibers and sham implant controls. Compressed mats of three types of glass microfibers were implanted subcutaneously in rats and tissues surrounding the implant sites histologically evaluated 2-4 weeks post surgery. Bioactive borate glass 13-93B3 supplemented with 0.4 wt % copper promoted extensive angiogenesis as compared to silica glass microfibers and sham control tissues. The angiogenic responses suggest the copper-containing 13-93B3 microfibers may be effective for treating chronic soft tissue wounds. A second objective was to assess the possible systemic cytotoxicity of dissolved borate ions and other materials released from implanted borate glass microfibers. Cytotoxicity was assessed via histological evaluation of kidney tissue collected from animals 4 weeks after subcutaneously implanting high amounts of the borate glass microfibers. The evaluation of the kidney tissue from these animals showed no evidence of chronic histopathological changes in the kidney. The overall results indicate the borate glass microfibers are safe and effective for soft tissue applications. © 2014 Wiley Periodicals, Inc.
Fügl, Alexander; Zechner, Werner; Pozzi, Alessandro; Heydecke, Guido; Mirzakhanian, Christine; Behneke, Nikolaus; Behneke, Alexandra; Baer, Russell A; Nölken, Robert; Gottesman, Edward; Colic, Snjezana
2017-07-01
The aim of this multicenter prospective clinical study was to evaluate anodized tapered implants with a conical connection and integrated platform shifting placed in the anterior and premolar maxilla. The study enrolled patients requiring single-tooth restorations in healed sites of maxillary anterior and premolar teeth. All implants were immediately temporized. Clinical and radiographic evaluations were conducted at implant insertion, 6 months, and 1 year. Outcome measures included bone remodeling, cumulative survival rate (CSR), success rate, soft-tissue health and esthetics, and patient satisfaction. Bone remodeling and pink esthetic score were analyzed using Wilcoxon signed-rank tests. CSR was calculated using life table analysis. Other soft-tissue outcomes were analyzed using sign tests. Out of 97 enrolled patients (102 implants), 87 patients (91 implants) completed the 1-year visit. Marginal bone remodeling was -0.85 ± 1.36 mm. After the expected initial bone loss, a mean bone gain of 0.11 ± 1.05 mm was observed between 6 months and 1 year. The CSR was 99.0%, and the cumulative success rate was 97.0%. Partial or full papilla was observed at 30.8% of sites at baseline, 87.2% at 6 months, and 90.5% at 1 year. Soft-tissue response, esthetics, and patient satisfaction all improved during the study period. Bone gain was observed following the expected initial bone loss, and soft-tissue outcomes improved suggesting favorable tissue response using anodized tapered conical connection implants. Rapid stabilization of bone remodeling and robust papilla regeneration indicate favorable tissue healing promoted by the conical connection, platform-shift design. clinicaltrials.gov NCT02175550.
Cross polarization optical coherence tomography for diagnosis of oral soft tissues
NASA Astrophysics Data System (ADS)
Gladkova, Natalia; Karabut, Maria; Kiseleva, Elena; Robakidze, Natalia; Muraev, Alexander; Fomina, Julia
2011-03-01
We consider the capabilities of cross-polarization OCT (CP OCT) focused on comparison of images resulting from cross-polarization and co-polarization scattering simultaneously for diagnosis of oral soft tissues. CP OCT was done for 35 patients with dental implants and 30 patients with inflammatory intestine diseases. Our study showed good diagnostic capabilities of CP OCT for detecting soft tissue pathology in the oral cavity. The cross-polarized images demonstrate the ability of tissue to depolarize. CP OCT demonstrates clinical capabilities for early diagnosis of inflammatory intestine diseases by the state of oral cavity mucosa and for early detection of gingivitis in patients above implant.
Benic, Goran I; Elmasry, Moustafa; Hämmerle, Christoph H F
2015-09-01
To examine the literature on novel digital imaging techniques for the assessment of outcomes in oral rehabilitation with dental implants. An electronic search of Medline and Embase databases including studies published prior to 28th December 2014 was performed and supplemented by a manual search. A synthesis of the publications was presented describing the use of computed tomography (CT), magnetic resonance imaging (MRI), ultrasonography, optical scanning, spectrophotometry or optical coherence tomography (OCT) related to the outcome measures in implant therapy. Most of the digital imaging techniques have not yet sufficiently been validated to be used for outcome measures in implant dentistry. In clinical research, cone beam CT (CBCT) is increasingly being used for 3D assessment of bone and soft tissue following augmentation procedures and implant placement. Currently, there are no effective methods for the reduction of artifacts around implants in CBCT. Optical scanning is being used for the 3D assessment of changes in the soft tissue contour. The combination of optical scan with pre-operative CBCT allows the determination of the implant position and its spatial relation to anatomical structures. Spectrophotometry is the method most commonly used to objectively assess the color match of reconstructions and peri-implant mucosa to natural dentition and gingiva. New optical imaging techniques may be considered possible approaches for monitoring peri-implant soft tissue health. MRI and ultrasonography appear promising non-ionizing radiation imaging modalities for the assessment of soft tissue and bone defect morphologies. Optical scanners and OCT may represent efficient clinical methods for accurate assessment of the misfit between the reconstructions and the implants. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Periodontal and peri-implant wound healing following laser therapy.
Aoki, Akira; Mizutani, Koji; Schwarz, Frank; Sculean, Anton; Yukna, Raymond A; Takasaki, Aristeo A; Romanos, Georgios E; Taniguchi, Yoichi; Sasaki, Katia M; Zeredo, Jorge L; Koshy, Geena; Coluzzi, Donald J; White, Joel M; Abiko, Yoshimitsu; Ishikawa, Isao; Izumi, Yuichi
2015-06-01
Laser irradiation has numerous favorable characteristics, such as ablation or vaporization, hemostasis, biostimulation (photobiomodulation) and microbial inhibition and destruction, which induce various beneficial therapeutic effects and biological responses. Therefore, the use of lasers is considered effective and suitable for treating a variety of inflammatory and infectious oral conditions. The CO2 , neodymium-doped yttrium-aluminium-garnet (Nd:YAG) and diode lasers have mainly been used for periodontal soft-tissue management. With development of the erbium-doped yttrium-aluminium-garnet (Er:YAG) and erbium, chromium-doped yttrium-scandium-gallium-garnet (Er,Cr:YSGG) lasers, which can be applied not only on soft tissues but also on dental hard tissues, the application of lasers dramatically expanded from periodontal soft-tissue management to hard-tissue treatment. Currently, various periodontal tissues (such as gingiva, tooth roots and bone tissue), as well as titanium implant surfaces, can be treated with lasers, and a variety of dental laser systems are being employed for the management of periodontal and peri-implant diseases. In periodontics, mechanical therapy has conventionally been the mainstream of treatment; however, complete bacterial eradication and/or optimal wound healing may not be necessarily achieved with conventional mechanical therapy alone. Consequently, in addition to chemotherapy consisting of antibiotics and anti-inflammatory agents, phototherapy using lasers and light-emitting diodes has been gradually integrated with mechanical therapy to enhance subsequent wound healing by achieving thorough debridement, decontamination and tissue stimulation. With increasing evidence of benefits, therapies with low- and high-level lasers play an important role in wound healing/tissue regeneration in the treatment of periodontal and peri-implant diseases. This article discusses the outcomes of laser therapy in soft-tissue management, periodontal nonsurgical and surgical treatment, osseous surgery and peri-implant treatment, focusing on postoperative wound healing of periodontal and peri-implant tissues, based on scientific evidence from currently available basic and clinical studies, as well as on case reports. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Kolerman, Roni; Nissan, Joseph; Mijiritsky, Eitan; Hamoudi, Nasreen; Mangano, Carlo; Tal, Haim
2016-11-01
Esthetic assessment of immediately restored implants combined with GBR and free connective tissue (CT) graft METHODS: A case-control, retrospective study involving 34 patients treated with maxillary anterior single implants, immediately placed and restored. Clinical and esthetic results were analyzed using standard clinical examination and a comprehensive index, comprising pink esthetic and white esthetic scores (PES/WES). The height of the implant crown and the corresponding height of the contralateral tooth crown were measured to identify mucosal recessions. The distance from the mucosal margin to the implant shoulder (DIM) was measured on the master model. Thirty of 34 implants fulfilled the strict success criteria set for dental implants with regard to osseointegration. Success was defined as implants with bone loss not exceeding 1.5 mm during the first year and loosing not more than 0.2 for each successive year. The other four implants were stable but did not meet the bone loss criteria mentioned above and defined as survived implants. Mean PES/WES was 14.44 ± 2.34 (range: 9-20). Mean PES was 7.12 ± 1.89 (range: 1-10). The highest mean values were achieved for the variable of root convexity/soft tissue color and texture (1.71 ± 0.46) whereas the mesial papilla (1.09 ± 0.62) proved to be the least pleasing. The mean WES was 7.32 ± 1.25 (range: 5-10). The difference between IC and contralateral TC was 0.54 mm. The mean value for the facial DIM was 3.82 ± 0.87 mm. An evaluation of soft and hard tissue augmentation in immediately restored immediate implant procedures was employed to obtain stable hard and soft tissues. The combined GBR and CT graft procedure achieved favorable peri-implant soft tissue condition and esthetic results. However, recession and incomplete papillas were frequently observed. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Cooper, Lyndon F; Reside, Glenn J; Raes, Filiep; Garriga, Joan Soliva; Tarrida, Luis Giner; Wiltfang, Jörg; Kern, Matthias; De Bruyn, Hugo
2014-01-01
This 5-year prospective multicenter study compared implant survival and success, peri-implant health and soft tissue responses, crestal bone level stability, and complication rates following immediate loading of single OsseoSpeed implants placed in anterior maxillary healed ridges or extraction sockets. Individuals requiring anterior tooth replacement with single implants were treated and immediately provisionalized. Definitive all-ceramic crowns were placed at 12 weeks. Implant survival, bone levels, soft tissue levels, and peri-implant health were monitored for 5 years. One hundred thirteen patients received implants in fresh sockets (55) and healed ridges (58). After 5 years, 45 and 49 patients remained for evaluation, respectively. During the first year, three implants failed in the extraction socket group (94.6% survival) and one implant failed in the healed ridge group (98.3% survival); this difference was not significant. No further implant failures were recorded. After 5 years, the interproximal crestal bone levels were located a mean of 0.43 ± 0.63 mm and 0.38 ± 0.62 mm from the reference points of implants in sockets and healed ridges (not a significant difference). In both groups, papillae increased over time and peri-implant mucosal zenith positions were stable from the time of definitive crown placement in sockets and healed ridges. Compared to flap surgery for implants in healed ridges, flapless surgery resulted in increased peri-implant mucosal tissue dimension (average, 0.78 ± 1.34 mm vs 0.19 ± 0.79 mm). After 5 years, the bone and soft tissue parameters that characterize implant success and contribute to dental implant esthetics were similar following the immediate provisionalization of implants in sockets and healed ridges. The overall tissue responses and reported implant survival support the immediate provisionalization of dental implants in situations involving healed ridges and, under ideal circumstances, extraction sockets.
Song, Kwangsun; Kim, Juho; Cho, Sungbum; Kim, Namyun; Jung, Dongwuk; Choo, Hyuck; Lee, Jongho
2018-06-25
Implantable electronics in soft and flexible forms can reduce undesired outcomes such as irritations and chronic damages to surrounding biological tissues due to the improved mechanical compatibility with soft tissues. However, the same mechanical flexibility also makes it difficult to insert such implants through the skin because of reduced stiffness. In this paper, a flexible-device injector that enables the subcutaneous implantation of flexible medical electronics is reported. The injector consists of a customized blade at the tip and a microflap array which holds the flexible implant while the injector penetrates through soft tissues. The microflap array eliminates the need of additional materials such as adhesives that require an extended period to release a flexible medical electronic implant from an injector inside the skin. The mechanical properties of the injection system during the insertion process are experimentally characterized, and the injection of a flexible optical pulse sensor and electrocardiogram sensor is successfully demonstrated in vivo in live pig animal models to establish the practical feasibility of the concept. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Vendemia, Nicholas; Chao, Jerry; Ivanidze, Jana; Sanelli, Pina; Spinelli, Henry M
2011-01-01
Medpor (Porex Surgical, Inc, Newnan, GA) is composed of porous polyethylene and is commonly used in craniofacial reconstruction. When complications such as seroma or abscess formation arise, diagnostic modalities are limited because Medpor is radiolucent on conventional radiologic studies. This poses a problem in situations where imaging is necessary to distinguish the implant from surrounding tissues. To present a clinically useful method for imaging Medpor with conventional computed tomographic (CT) scanning. Eleven patients (12 total implants) who have undergone reconstructive surgery with Medpor were included in the study. A retrospective review of CT scans done between 1 and 16 months postoperatively was performed using 3 distinct CT window settings. Measurements of implant dimensions and Hounsfield units were recorded and qualitatively assessed. Of the 3 distinct window settings studied, namely, "bone" (W1100/L450), "soft tissue"; (W500/L50), and "implant" (W800/L200), the implant window proved the most ideal, allowing the investigators to visualize and evaluate Medpor in all cases. Qualitative analysis revealed that Medpor implants were able to be distinguished from surrounding tissue in both the implant and soft tissue windows, with a density falling between that of fat and fluid. In 1 case, Medpor could not be visualized in the soft tissue window, although it could be visualized in the implant window. Quantitative analysis demonstrated a mean (SD) density of -38.7 (7.4) Hounsfield units. Medpor may be optimally visualized on conventional CT scans using the implant window settings W800/L200, which can aid in imaging Medpor and diagnosing implant-related complications.
Parpaiola, Andrea; Sbricoli, Luca; Guazzo, Riccardo; Bressan, Eriberto; Lops, Diego
2013-10-01
The proper representation of soft tissue contours for a natural aspect of the peri-implant mucosa and its mimesis with the adjacent teeth is a crucial aspect of the esthetic area restoration. This paper describes a method for the easy transfer of the peri-implant tissue morphology onto impression material with a view to achieving an accurate, custom implant restoration. The procedure described is suitable both for single and multi-unit implant-supported prostheses. Once the peri-implant mucosa is sculpted by the provisional restoration, the emergence profile is duplicated. The implant analog is embedded into laboratory stone or plaster in a mixing cup and allowed to set. The provisional restoration is removed from the oral cavity and screwed to the implant analog; then, a polyether material is placed in the mixing cup so that the provisional restoration is put into impression material at the level of the prosthetic emergence profile. After the polyether polymerizing, the provisional prosthesis is unscrewed and replaced with the stock hexed transfer for the final impression. Next, cold self-curing resin is poured into this gap and left to set. A custom transfer for this single implant site is thus obtained. This modified transfer is then removed and screwed onto the implant in the oral cavity for the definitive impression. The technique described enables a faithful reproduction of the peri-implant soft tissues and emergence profile. An emergence profile that mimics the natural tooth should be obtained by successful esthetic implant restoration. Moreover, it allows proper hygiene, which is fundamental for implant maintenance. The best way to achieve the correct emergence profile is to sculpture the peri-implant mucosa by means of a provisional prosthesis. Prefabricated provisional crowns cannot mimic the complexity and the variations of human soft tissue. Therefore, only a chair-side modification of the provisional restoration can accomplish the optimal result. Such a requirement can be satisfied by the clinical method described in the present report. © 2013 Wiley Periodicals, Inc.
The Future of Biologic Coatings for Orthopaedic Implants
Goodman, Stuart B.; Yao, Zhenyu; Keeney, Michael; Yang, Fan
2013-01-01
Implants are widely used for othopaedic applications such as fixing fractures, repairing nonunions, obtaining a joint arthrodesis, total joint arthroplasty, spinal reconstruction, and soft tissue anchorage. Previously, orthopaedic implants were designed simply as mechanical devices; the biological aspects of the implant were a byproduct of stable internal/external fixation of the device to the surrounding bone or soft tissue. More recently, biologic coatings have been incorporated into orthopaedic implants in order to modulate the surrounding biological environment. This opinion article reviews current and potential future use of biologic coatings for orthopaedic implants to facilitate osseointegration and mitigate possible adverse tissue responses including the foreign body reaction and implant infection. While many of these coatings are still in the preclinical testing stage, bioengineers, material scientists and surgeons continue to explore surface coatings as a means of improving clinical outcome of patients undergoing orthopaedic surgery. PMID:23391496
Soft Tissue Alterations in Esthetic Postextraction Sites: A 3-Dimensional Analysis.
Chappuis, V; Engel, O; Shahim, K; Reyes, M; Katsaros, C; Buser, D
2015-09-01
Dimensional alterations of the facial soft and bone tissues following tooth extraction in the esthetic zone play an essential role to achieve successful outcomes in implant therapy. This prospective study is the first to investigate the interplay between the soft tissue dimensions and the underlying bone anatomy during an 8-wk healing period. The analysis is based on sequential 3-dimensional digital surface model superimpositions of the soft and bone tissues using digital impressions and cone beam computed tomography during an 8-wk healing period. Soft tissue thickness in thin and thick bone phenotypes at extraction was similar, averaging 0.7 mm and 0.8 mm, respectively. Interestingly, thin bone phenotypes revealed a 7-fold increase in soft tissue thickness after an 8-wk healing period, whereas in thick bone phenotypes, the soft tissue dimensions remained unchanged. The observed spontaneous soft tissue thickening in thin bone phenotypes resulted in a vertical soft tissue loss of only 1.6 mm, which concealed the underlying vertical bone resorption of 7.5 mm. Because of spontaneous soft tissue thickening, no significant differences were detected in the total tissue loss between thin and thick bone phenotypes at 2, 4, 6, and 8 wk. More than 51% of these dimensional alterations occurred within 2 wk of healing. Even though the observed spontaneous soft tissue thickening in thin bone phenotypes following tooth extraction conceals the pronounced underlying bone resorption pattern by masking the true bone deficiency, spontaneous soft tissue thickening offers advantages for subsequent bone regeneration and implant therapies in sites with high esthetic demand (Clinicaltrials.gov NCT02403700). © International & American Associations for Dental Research.
Rokn, A; Bassir, S H; Rasouli Ghahroudi, A A; Kharazifard, M J; Manesheof, R
2016-01-01
The present study aimed to evaluate the long-term stability of esthetic outcomes of soft tissue around maxillary anterior single-tooth implants after 10-to-12 years of loading. Patients who had been treated for single-tooth implants in the anterior maxilla between February 2000 and July 2002 were invited to participate in the study. All implants had been placed according to delayed implant placement and conventional loading protocols without any connective tissue graft or papilla preservation flaps. Pink Esthetic Score (PES) was rated using standardized clinical photographs to assess the esthetic outcomes of the implant treatment at the time of crown placement and at time of follow-up examination which was at least 10 years after the crown placement. A total of 19 patients were included. The mean score of PES was 11.63 (SD 1.61; range 7-14) at baseline. After 10-to-12 years of function, a mean PES score of 11.05 (SD 2.09; range 6-14) was recorded. No significant differences were found in the esthetic outcomes, categorized based on clinically relevant levels, between the baseline and follow-up session (p>0.05). Within limitation of the present study, it can be concluded that the esthetic outcomes of soft tissue around the maxillary anterior single-tooth implants placed using conventional implant placement technique remained stable in the long-term.
Hard and soft tissue surgical complications in dental implantology.
Aziz, Shahid R
2015-05-01
This article discusses surgical complications associated with the placement of dental implants, specifically focusing on how they occur (etiology), as well as their management and prevention. Dental implant surgical complications can be classified into those of hard and soft tissues. In general, complications can be avoided with thorough preoperative treatment planning and proper surgical technique. Copyright © 2015 Elsevier Inc. All rights reserved.
Intra-oral soft tissue expansion and volume stability of onlay bone grafts.
Abrahamsson, Peter
2011-01-01
Insufficient regeneration of missing bone and soft-tissue may present aesthetic or functional problems in patients indicated for dental implant surgery. Several techniques such as bone grafts, bone substitutes and guided tissue regeneration (GTR) have been described to rebuild a compromised alveolar ridge. Adequate soft-tissue coverage of grafted bone and titanium-mesh is important to avoid exposure which may result in loss of the bone graft. The general aim of this thesis was to evaluate use of an osmotic tissue expander for expanding intra-oral soft tissue--creating a surplus of soft tissue-- in preparation for onlay bone grafting. An experimental rabbit model was used in studies (I), (II) and (III). In (I) an osmotic soft-tissue expander was placed bilaterally on the lateral wall of the mandible via an extra-oral approach. After two weeks of expansion the rabbits were killed and specimens were collected for histology. No inflammatory reaction and no resorbtion of the cortical bone occured. The periosteum was expanded and new bone formation was seen in the edges of the expander. In (II) and (III) the expander was placed under the periosteum in the same way as in (I): bilaterally in 13 rabbits in (II) and unilaterally in 11 rabbits in (III). After two weeks of expansion the expander was identified and removed. In (II) particulated bone was placed at the recipient site protected by a titanium mesh in one site and a bio-resorbable mesh on the other site. In (III), DBBM particles and bone particles collected from the lateral border of the mandible separated by a collagen membrane was placed at the recipient site. The graft was protected by a pre-bent titanium mesh covered by a collagen membrane. After a healing period of 3 months specimens were collected for histological and SEM examination. New bone was growing in direct contact with the titanium mesh and bio resorbable mesh. The newly formed bone had the same calcium content as the mature bone in the base of the mandible. In the clinical study (IV) 20 patients were consecutively recruited and randomised into two groups. The experimental group (ten patients) had an osmotic soft tissue expander implanted. After two weeks of expansion the expander was removed and a particulated bone graft protected by a titanium mesh and a collagen membrane was fixed to the recipient site. Titanium implants were installed after a healing period of 6 months. The patients in the reference group had a bone block grafted from the anterior ramus fixated to the recipient site with one or two titanium mini screws. Implants were installed after a healing period of 6 months. A three dimensional optical measuring device was used to measure alterations in the soft tissue profile before each surgical procedure. The three-dimensional changes were then analysed on a PC. The results from the clinical study in patients confirmed the results from the experimental rabbit studies. The osmotic tissue expander expanded the soft tissue. Expander perforations of the soft tissue occurred in two patients. The optical measurements demonstrated a positive volume gain after soft tissue expansion and bone grafting. The expanded tissue could be used to cover a bone graft. There still was a risk of mesh exposure, even after soft tissue expansion, which occurred in two patients. In both groups, implants could be installed in the grafted bone in positions that would allow the crowns to fit aesthetically into the dental arch.
Bengazi, Franco; Lang, Niklaus P; Caroprese, Marino; Urbizo Velez, Joaquin; Favero, Vittorio; Botticelli, Daniele
2015-02-01
To study the buccal dimensional tissue changes at oral implants following free gingival grafting, with or without including the keratin layer, performed at the time of implant installation into alveolar mucosa. The mandibular premolars and first molars were extracted bilaterally in six Beagle dogs. In the right side of the mandible (Test), flaps were first elevated, and the buccal as well as part of the lingual masticatory mucosa was removed. An incision of the periosteum at the buccal aspect was performed to allow the flap to be coronally repositioned. Primary wound closure was obtained. In the left side, the masticatory (keratinized) mucosa was left in situ, and no sutures were applied (Control). After 3 months of healing, absence of keratinized mucosa was confirmed at the test sites. Two recipient sites were prepared at each side of the mandible in the region of the third and fourth premolars. All implants were installed with the shoulder placed flush with the buccal alveolar bony crest, and abutments were connected to allow a non-submerged healing. Two free gingival mucosal grafts were harvested from the buccal region of the maxillary canines. One graft was left intact (gingival mucosal graft), while for the second, the epithelial layer was removed (gingival connective tissue graft). Subsequently, the grafts were fixed around the test implants in position of the third and fourth premolars, respectively. After 3 months, the animals were euthanized and ground sections obtained. Similar bony crest resorption and coronal extension of osseointegration were found at test and control sites. Moreover, similar dimensions of the peri-implant soft tissues were obtained at test and control sites. The increase in the alveolar mucosal thickness by means of a gingival graft affected the peri-implant marginal bone resorption and soft tissue recession around implants. This resulted in outcomes that were similar to those at implants surrounded by masticatory mucosa, indicating that gingival grafting in the absence of keratinized mucosa around implants may reduce the resorption of the marginal crest and soft tissue recession. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Gulati, Karan; Ivanovski, Sašo
2017-08-01
The transmucosal nature of dental implants presents a unique therapeutic challenge, requiring not only rapid establishment and subsequent maintenance of osseointegration, but also the formation of resilient soft tissue integration. Key challenges in achieving long-term success are sub-optimal bone integration in compromised bone conditions and impaired trans-mucosal tissue integration in the presence of a persistent oral microbial biofilm. These challenges can be targeted by employing a drug-releasing implant modification such as TiO 2 nanotubes (TNTs), engineered on titanium surfaces via electrochemical anodization. Areas covered: This review focuses on applications of TNT-based dental implants towards achieving optimal therapeutic efficacy. Firstly, the functions of TNT implants will be explored in terms of their influence on osseointegration, soft tissue integration and immunomodulation. Secondly, the developmental challenges associated with such implants are reviewed including sterilization, stability and toxicity. Expert opinion: The potential of TNTs is yet to be fully explored in the context of the complex oral environment, including appropriate modulation of alveolar bone healing, immune-inflammatory processes, and soft tissue responses. Besides long-term in vivo assessment under masticatory loading conditions, investigating drug-release profiles in vivo and addressing various technical challenges are required to bridge the gap between research and clinical dentistry.
Zhao, L P; Zhan, Y L; Hu, W J; Wang, H J; Wei, Y P; Zhen, M; Xu, T; Liu, Y S
2016-12-18
For ideal implant rehabilitation, an adequate bone volume, optical implant position, and stable and healthy soft tissue are required. The reduction of alveolar bone and changes in its morphology subsequent to tooth extraction will result in insufficient amount of bone and adversely affect the ability to optimally place dental implants in edentulous sites. Preservation of alveolar bone volume through ridge preservation has been demonstrated to reduce the vertical and horizontal contraction of the alveolar bone crest after tooth extraction and reduce the need for additional bone augmentation procedures during implant placement. In this case, a patient presented with a mandible molar of severe periodontal disease, the tooth was removed as atraumatically as possible and the graft material of Bio-Oss was loosely placed in the alveolar socket without condensation and covered with Bio-Gide to reconstruct the defects of the alveolar ridge. Six months later, there were sufficient height and width of the alveolar ridge for the dental implant, avoiding the need of additional bone augmentation and reducing the complexity and unpredictability of the implant surgery. Soft tissue defects, such as gingival and connective tissue, played crucial roles in long-term implant success. Peri-implant plastic surgery facilitated development of healthy peri-implant structure able to withstand occlusal forces and mucogingival stress. Six months after the implant surgery, the keratinized gingiva was absent in the buccal of the implant and the vestibular groove was a little shallow. The free gingival graft technique was used to solve the vestibulum oris groove supersulcus and the absence of keratinized gingiva around the implant. The deepening of vestibular groove and broadening of keratinized gingiva were conducive to the long-term health and stability of the tissue surrounding the implant. Implant installation and prosthetic restoration showed favorable outcome after six months.
Liu, Changying; Su, Yucheng; Tan, Baosheng; Ma, Pan; Wu, Gaoyi; Li, Jun; Geng, Wei
2014-01-01
Objectives: The purpose of this study was to recommend a new method using acellular dermal matrix graft and resin splint to reconstruct the attached soft tissue around dental implants in patients with maxillofacial defects. Materials and methods: Total 8 patients (3 male and 5 female patients) diagnosed with maxillofacial defects and dentition defects caused by tumors, fractures or edentulous jaw, were selected for this study. Dental implants were routinely implanted at the edentulous area. Acellular dermal matrix heterografts and resin splint were used to increase the attached soft tissue. The width of attached gingiva in the labial or buccal surface at edentulous area was measured before surgical procedures and after the completion of superstructures. Paired t-test was applied to assess the change of quantitative variables. All tests were 2-tailed, and P < 0.05 was considered statistically significant. Results: The dense connective tissue around implants could be reconstructed one month after the completion of surgical procedures, and the epithelial cuff around the implant neck established very well. The width of attached gingival tissue in the patients increased significantly from a mean of 0.61 ± 0.75 mm to 6.25 ± 1.04 mm. The patients were fully satisfied with the esthetic and functional results achieved. Conclusions: The acellular dermal matrix graft could be used to increase the attached gingiva around dental implants in these patients with maxillofacial defects. The resin splint could facilitate the healing of graft. PMID:25663964
Histological analysis of soft and hard tissues in a periimplantitis lesion: a human case report.
Jung, Soong-Ryong; Bashutski, Jill D; Jandali, Rami; Prasad, Hari; Rohrer, Michael; Wang, Hom-Lay
2012-06-01
Little is known regarding the histologic hard and soft tissue changes that occur in chronic periimplantitis situations in humans. It is critical to gain an understanding of all aspects of periimplantitis to develop appropriate therapeutic approaches. An 83-year-old African American man presented with a fractured implant affected by severe, chronic periimplantitis and surrounded by keratinized gingiva. A trephine biopsy of the implant and surrounding tissues was analyzed histologically. Histological analysis of the periimplantitis specimen revealed significant inflammatory infiltrate consisting predominantly of lymphocytes and plasma cells. In addition, epithelial migration and bone loss to the apical vent were noted. This case report documents a single case of periimplantitis that was left untreated for 7 years. The presence of significant keratinized tissue and a smooth surface implant failed to prevent fibrous encapsulation of the implant.
Lops, Diego; Bressan, Eriberto; Parpaiola, Andrea; Sbricoli, Luca; Cecchinato, Denis; Romeo, Eugenio
2015-12-01
Aim of this study was to verify if the type of implant abutment manufacturing, stock or cad-cam, could influence the maintenance of stable gingival margins around single restorations in anterior areas. After 16 weeks of healing, implants (Osseospeed, Astra Tech Dental Implant) were positioned. Depending on the different fixture inclination and the thickness of buccal peri-implant soft tissue, abutment selection resulted in four groups: Group 1 (patients with zirconia ZirDesign(®) stock abutments), Group 2 (titanium stock TiDesign(®) abutments), Group 3 (zirconia cad-cam abutments), and Group 4 (titanium cad-cam abutments). The following parameters were assessed: buccal gingival margin modification (BGM). The modification of the implant gingival margin was followed at 1 and 2 years of follow-up. A computerized analysis was performed for measurements. Differences between soft tissue margin at baseline and after 2 years measured the gingival margin recession. A general linear model was used to evaluate each group in relation to gingival recession after two years. Tukey's post hoc test was used to compare the mean REC indexes of each group of abutments. Seventy-two healthy patients (39 males and 33 females; mean age of 46 years) scheduled for single gap rehabilitation in anterior areas were enrolled. A 100% of implant survival rate was observed after 24 months of function. One failure occurred due to fracture of a Zirconia cad-cam abutment. Moreover, two abutment screw unscrewing were observed. Both for zirconia and titanium stock abutments (Group 1 and 2), the mean recession of implant buccal soft tissue was of 0.3 mm (SD of 0.3 and 0.4 mm, respectively). Soft tissue mean recession of zirconia and titanium cad-cam abutments (Group 3 and 4) was of 0.1 and -0.3 mm, respectively (SD of 0.3 and 0.4 mm, respectively). REC values of cad-cam titanium abutments (Group 4) were significantly lower than that of Group 1 (-0.57 mm), Group 2 (-0.61 mm), and Group 3 (-0.40 mm), respectively (Table 4). In the anterior area, the use of cad-cam abutments is related to a better soft tissue stability. Such a relationship is significant if cad-cam titanium abutments are compared to both titanium and zirconia stock abutments. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Imburgia, Mario; Del Fabbro, Massimo
2015-10-01
Studies are needed to evaluate long-term performance of immediately loaded implants with moderately rough surface. This retrospective study evaluated long-term survival and periimplant soft and hard tissue conditions in patients treated with TiUnite implants. Forty-one consecutive patients (mean age, 52.6 years) received 205 Brånemark System Mk III TiUnite implants (145 maxillary, 60 mandibular). The indication was single tooth (n = 7 implants), partial (n = 94), or full arches (n = 104). One hundred thirteen implants were immediately loaded. Cumulative survival rate (CSR) of implants was assessed. Long-term marginal bone remodeling, probing pocket depth (PPD), and periimplant mucosa conditions were assessed. Follow-up averaged 8.8 years (range, 6.6-10.6 years). Eight implants in 5 patients failed. CSR was 96.1% (implant basis) and 87.8% (patient basis) up to 10 years. At the longest follow-up, bone loss averaged 0.43 ± 1.15 mm (n = 173), PPD averaged 3.64 ± 0.74 mm, and periimplant mucosa was healthy in 74.6% of cases. Furthermore, 50.3% and 35.5% of implants scored negative for plaque and bleeding, respectively. No significant difference in CSR and hard and soft tissue conditions was found in the long term between immediately and delayed loaded implants. Implants with TiUnite surface demonstrated excellent long-term survival, marginal bone response, and soft tissue conditions, despite a nonoptimal level of oral hygiene.
Soft tissue augmentation procedures for mucogingival defects in esthetic sites.
Levine, Robert A; Huynh-Ba, Guy; Cochran, David L
2014-01-01
This systematic review was performed to address the focus question: "In adult patients with soft tissue deficiencies around maxillary anterior implants, what is the effect on esthetic outcomes when a soft tissue procedure is performed?" In addition, this paper reviews the importance of presurgical esthetic risk assessment (ERA) starting with comprehensive team case planning prior to surgical intervention and a restorative-driven approach. A thorough Medline database search performed on related MeSH terms yielded 1,532 titles and selected abstracts that were independently screened. Out of the 351 abstracts selected, 123 full-text articles were obtained for further evaluation. At each level, any disagreements were discussed until a consensus was reached. A total of 18 studies were included in this systematic review of esthetic outcomes following soft tissue procedures around implants with soft tissue deficiencies. A preliminary analysis of the included studies showed that the vast majority were case series studies with most not providing objective outcomes of their results. Moreover, only one randomized controlled trial was identified. Therefore, quantitative data analysis and subsequent meta-analysis could not be performed. The included studies were grouped according to the intervention on the peri-implant soft tissue performed and six groups were identified. The periodontal procedures performed around dental implants gave initial good results from the inflammation involved in wound healing, but in virtually all cases significant recession occurred as healing resolved and the tissues matured. Although success of implant therapy is similar in the anterior maxilla and other areas of the mouth, the majority of studies evaluating this therapy in the esthetic zone are lacking literature support, few in number, devoid of long-term follow-up and number of patients, and are subject to inclusion bias. The use of the ERA tool for all esthetic zone cases can benefit both the clinician and the patient to avoid any miscommunication and problems of expectation upon completion. All the available knowledge on this topic, including the approaches described in this paper, is based on a very limited literature support and thus should be addressed with caution. These concerns should encourage long-term good clinical trials for better assessment of those issues.
Zhang, Yi-ming; Wang, Shao-liang; Lei, Ze-yuan; Fan, Dong-li
2009-09-01
Although silicone rubber (SR) implants are most commonly used and effective for soft-tissue augmentation, they still have been implicated in many adverse reactions. To overcome this problem, a novel composite beta-tricalcium phosphate/silicone rubber (beta-TCP/SR) was prepared by adding beta-TCP into a SR matrix. This study was to evaluate its application potential by investigating the mechanical properties and biocompatibility of beta-TCP/SR. Mechanical properties, including Shore A hardness and tensile strength, were evaluated with 3-mm-thick samples and a universal testing machine. Cytocompatibility tests were conducted in vitro using 0.2-mm-thick beta-TCP/SR samples by seeding fibroblasts onto different samples. Soft-tissue response to beta-TCP/SR and pull-out measurements were investigated 4 weeks and 24 weeks after implantation. The main mechanical properties were all significantly changed after mixing beta-TCP into the SR matrix, except for tearing strength. The cytocompatibility test showed enhanced adhesion and proliferation of fibroblasts onto beta-TCP/SR. Fibrous tissue ingrowth after resorption of beta-TCP was observed by in vivo histologic analysis. The peri-implant capsules in the beta-TCP/SR group were thinner than in the SR group 24 weeks after implantation. In a 24-week test, the maximum force required to pull out the beta-TCP/SR sheet was about six times greater than that needed for SR. Although some mechanical properties were significantly changed, the results of the cytocompatibility test and in vivo animal study still suggest that beta-TCP/SR may be more suitable as a soft-tissue implant than SR and has the potential to be used in plastic surgery.
Revisiting peri-implant soft tissue – histopathological study of the peri-implant soft tissue
Silva, Eduarda; Félix, Sérgio; Rodriguez-Archilla, Alberto; Oliveira, Pedro; Martins dos Santos, José
2014-01-01
Peri-implant soft tissues are essential for osseointegration. The peri-implant mucosa may lack vascular supply, and histological observation, even without plaque, shows the presence of inflammatory cells. The objectives of this study were to assess the histopathological changes of the epithelium and connective tissue around the implant. Twenty patients of both genders were studied. Twelve weeks after implant placement, fragments of peri-implant gingival sulcus were harvested and processed for light microscopy. Group I (10): without clinical inflammatory signs (control); Group II (10): with clinical inflammatory signs. Histopathological parameters were analyzed and classified in 3 grades: mild, moderate or severe (grade 1, 2 or 3). Control group showed only slight changes, grade 1. In group II we found edema with moderate to severe cellular and nuclear changes. There are more women than men with all grades of inflammation. All patients with moderate edema are male and all patients with severe edema are female. A significant association (p=0.007) exists between these two variables. Significant differences were found when comparing the degree of inflammation with nuclear alterations (p=0.001) and the same results when comparing the degree of edema and nuclear changes (p<0.001). This study demonstrates that clinical examination can be used, with a small margin of error, to monitor and control the state of the peri-implant mucosa. In clinics the predisposition of female patients to greater degree of edema and inflammation should be accounted for. PMID:24551281
Rokn, A; Bassir, SH; Rasouli Ghahroudi, AA; Kharazifard, MJ; Manesheof, R
2016-01-01
Purpose: The present study aimed to evaluate the long-term stability of esthetic outcomes of soft tissue around maxillary anterior single-tooth implants after 10-to-12 years of loading. Methods: Patients who had been treated for single-tooth implants in the anterior maxilla between February 2000 and July 2002 were invited to participate in the study. All implants had been placed according to delayed implant placement and conventional loading protocols without any connective tissue graft or papilla preservation flaps. Pink Esthetic Score (PES) was rated using standardized clinical photographs to assess the esthetic outcomes of the implant treatment at the time of crown placement and at time of follow-up examination which was at least 10 years after the crown placement. Results: A total of 19 patients were included. The mean score of PES was 11.63 (SD 1.61; range 7-14) at baseline. After 10-to-12 years of function, a mean PES score of 11.05 (SD 2.09; range 6–14) was recorded. No significant differences were found in the esthetic outcomes, categorized based on clinically relevant levels, between the baseline and follow-up session (p>0.05). Conclusion: Within limitation of the present study, it can be concluded that the esthetic outcomes of soft tissue around the maxillary anterior single-tooth implants placed using conventional implant placement technique remained stable in the long-term. PMID:27990185
Arora, Himanshu; Khzam, Nabil; Roberts, David; Bruce, William L; Ivanovski, Saso
2017-08-01
Immediate implant placement followed by an immediate restoration has proven to be a viable technique in the anterior maxillary region. This prospective study evaluated the mid-long term (2-5 years) tissue changes around immediately placed and restored implants in the anterior maxilla using flapless surgery and simultaneous hard tissue augmentation. Thirty AstraTech implants were immediately placed in 30 patients, followed by the delivery of an immediate provisional restoration on the same day. All participating 30 patients underwent the same treatment strategy that involved flapless removal of a failing maxillary anterior tooth, immediate implant placement, simultaneous augmentation with a deproteinized particulate xenograft, followed by the connection of a screw-retained provisional restoration. Radiographs and photographs were used to measure hard and soft tissue changes. Aesthetic evaluation was performed using the Pink Esthetic Score (PES). All implants remained osseointegrated during the follow up period of 2-5 years (mean 47 ± 15 months). Twelve of the thirty patients completed the 5 year follow up. Radiographic evaluation revealed average gains in bone levels of 0.18 and 0.34 mm mesially and distally, respectively. Soft tissue evaluation showed a mean tissue loss of 0.05 ± 0.64 mm and 0.16 ± 0.63 mm at the mesial and distal papillae, respectively, while mid-facial mucosal recession was 0.29 ± 0.74 mm. A significant improvement in the Pink Esthetic Scores was seen at the final follow-up (mean PES 11.50), as compared to the baseline (mean PES 10.27) (P = .001). In addition to a favorable implant success rate and peri-implant bony response, the soft tissue levels and overall aesthetics around single immediately placed and restored implants can also be maintained in the mid-long term. © 2017 Wiley Periodicals, Inc.
Guimarães, George Furtado; de Araújo, Vera Cavalcanti; Nery, James Carlos; Peruzzo, Daiane Cristina; Soares, Andresa Borges
2015-01-01
Enamel matrix derivative (EMD) is commonly used in periodontal therapy and has been used successfully for periodontal regeneration. In addition, this material has a possible angiogenic effect that has been associated with enhanced wound healing. The aim of this study was to evaluate the effect of EMD on microvessel density (angiogenesis) on the soft tissues surrounding newly placed implants after 14 days. Five patients were selected, each requiring at least one implant on each side of the maxilla, in a split-mouth experimental design. The implants were placed in a two-stage procedure. Each side was then randomized as test or control. On the test side, 0.1 mL of EMD was topically applied to the soft tissues surrounding the implants, while the control side did not receive any treatment. Second-stage surgery was performed after 14 days. A 6-mm punch biopsy was performed for each implant, with the samples subsequently prepared for histology and immunohistochemistry. Quantitative vascularization analysis was performed, which involved counting three areas or "hotspots" containing vessels strongly positive for CD34 and CD105, a pan-endothelial and new vessel marker, respectively. There was no significant difference between test and control groups when evaluating the formation of new blood vessels. The total number of blood vessels, however, was significantly higher in the group treated with EMD (test group). Within the limits of the present study, it can be concluded that topical application of EMD on the soft tissues surrounding newly placed implants resulted in an increased number of blood vessels at 14 days, suggesting that EMD may play a beneficial role in this aspect of wound healing.
2014-01-01
Background Adverse local tissue reaction (ALTR) is characterized by periprosthetic soft tissue inflammation composed of a mixed inflammatory cell infiltrate, extensive soft tissue necrosis, and vascular changes. Multiple hip implant classes have been reported to result in ALTR, and clinical differences may represent variation in the soft tissue response at the cellular and tissue levels. The purpose of this study was to describe similarities and differences in periprosthetic tissue structure, organization, and cellular composition by conventional histology and immunohistochemistry in ALTR resulting from two common total hip arthroplasty (THA) implant classes. Methods Consecutive patients presenting with ALTR from two major hip implant classes (N = 54 patients with Dual-Modular Neck implant; N = 14 patients with Metal-on-Metal implant) were identified from our prospective Osteolysis Tissue Database and Repository. Clinical characteristics including age, sex, BMI, length of implantation, and serum metal ion levels were recorded. Retrieved synovial tissue morphology was graded using light microscopy and cellular composition was assessed using immunohistochemistry. Results Length of implantation was shorter in the DMN group versus MoM THA group (21.3 [8.4] months versus 43.6 [13.8] months respectively; p < 0.005) suggesting differences in implant performance. Morphologic examination revealed a common spectrum of neo-synovial proliferation and necrosis in both groups. Macrophages were more commonly present in diffuse sheets (Grade 3) in the MoM relative to DMN group (p = 0.016). Perivascular lymphocytes with germinal centers (Grade 4) were more common in the DMN group, which trended towards significance (p = 0.066). Qualitative differences in corrosion product morphology were seen between the two groups. Immunohistochemistry showed features of a CD4 and GATA-3 rich lymphocyte reaction in both implants, with increased ratios of perivascular T-cell relative to B-cell markers in the DMN relative to the MoM group (p = 0.032). Conclusion Our results demonstrate that both implant classes display common features of neo-synovial proliferation and necrosis with a CD4 and GATA-3 rich inflammatory infiltrate. Qualitative differences in corrosion product appearance, macrophage morphology, and lymphocyte distributions were seen between the two implant types. Our data suggests that ALTR represents a histological spectrum with implant-based features. PMID:25242891
Perino, Giorgio; Ricciardi, Benjamin F; Jerabek, Seth A; Martignoni, Guido; Wilner, Gabrielle; Maass, Dan; Goldring, Steven R; Purdue, P Edward
2014-01-01
Adverse local tissue reaction (ALTR) is characterized by periprosthetic soft tissue inflammation composed of a mixed inflammatory cell infiltrate, extensive soft tissue necrosis, and vascular changes. Multiple hip implant classes have been reported to result in ALTR, and clinical differences may represent variation in the soft tissue response at the cellular and tissue levels. The purpose of this study was to describe similarities and differences in periprosthetic tissue structure, organization, and cellular composition by conventional histology and immunohistochemistry in ALTR resulting from two common total hip arthroplasty (THA) implant classes. Consecutive patients presenting with ALTR from two major hip implant classes (N = 54 patients with Dual-Modular Neck implant; N = 14 patients with Metal-on-Metal implant) were identified from our prospective Osteolysis Tissue Database and Repository. Clinical characteristics including age, sex, BMI, length of implantation, and serum metal ion levels were recorded. Retrieved synovial tissue morphology was graded using light microscopy and cellular composition was assessed using immunohistochemistry. Length of implantation was shorter in the DMN group versus MoM THA group (21.3 [8.4] months versus 43.6 [13.8] months respectively; p < 0.005) suggesting differences in implant performance. Morphologic examination revealed a common spectrum of neo-synovial proliferation and necrosis in both groups. Macrophages were more commonly present in diffuse sheets (Grade 3) in the MoM relative to DMN group (p = 0.016). Perivascular lymphocytes with germinal centers (Grade 4) were more common in the DMN group, which trended towards significance (p = 0.066). Qualitative differences in corrosion product morphology were seen between the two groups. Immunohistochemistry showed features of a CD4 and GATA-3 rich lymphocyte reaction in both implants, with increased ratios of perivascular T-cell relative to B-cell markers in the DMN relative to the MoM group (p = 0.032). Our results demonstrate that both implant classes display common features of neo-synovial proliferation and necrosis with a CD4 and GATA-3 rich inflammatory infiltrate. Qualitative differences in corrosion product appearance, macrophage morphology, and lymphocyte distributions were seen between the two implant types. Our data suggests that ALTR represents a histological spectrum with implant-based features.
Post-Surgical Clinical Monitoring of Soft Tissue Wound Healing in Periodontal and Implant Surgery
Pippi, Roberto
2017-01-01
Clinical features of surgical soft tissue wound healing in dentistry have been rarely discussed in the international literature. The aim of the present paper is to highlight both the main clinical findings of surgical wound healing, especially in periodontal and implant dentistry, and the wound healing monitoring procedures which should be followed. Wound inspection after careful food and plaque debridement is the essential part of wound healing monitoring. Periodontal and peri-implant probing should be performed only after tissue healing has been completed and not on a weekly basis in peri-implant tissue monitoring. Telephone follow-up and patient self-assessment scales can also be used the days following surgery to monitor the most common surgical complications such as pain, swelling, bleeding, and bruising. Wound healing monitoring is an important concern in all surgical procedures since it allows to identify signs or/and symptoms possibly related to surgical complications. PMID:28824306
Post-Surgical Clinical Monitoring of Soft Tissue Wound Healing in Periodontal and Implant Surgery.
Pippi, Roberto
2017-01-01
Clinical features of surgical soft tissue wound healing in dentistry have been rarely discussed in the international literature. The aim of the present paper is to highlight both the main clinical findings of surgical wound healing, especially in periodontal and implant dentistry, and the wound healing monitoring procedures which should be followed. Wound inspection after careful food and plaque debridement is the essential part of wound healing monitoring. Periodontal and peri-implant probing should be performed only after tissue healing has been completed and not on a weekly basis in peri-implant tissue monitoring. Telephone follow-up and patient self-assessment scales can also be used the days following surgery to monitor the most common surgical complications such as pain, swelling, bleeding, and bruising. Wound healing monitoring is an important concern in all surgical procedures since it allows to identify signs or/and symptoms possibly related to surgical complications.
Kretlow, James D.; Shi, Meng; Young, Simon; Spicer, Patrick P.; Demian, Nagi; Jansen, John A.; Wong, Mark E.; Kasper, F. Kurtis
2010-01-01
Current treatment of traumatic craniofacial injuries often involves early free tissue transfer, even if the recipient site is contaminated or lacks soft tissue coverage. There are no current tissue engineering strategies to definitively regenerate tissues in such an environment at an early time point. For a tissue engineering approach to be employed in the treatment of such injuries, a two-stage approach could potentially be used. The present study describes methods for fabrication, characterization, and processing of porous polymethylmethacrylate (PMMA) space maintainers for temporary retention of space in bony craniofacial defects. Carboxymethylcellulose hydrogels were used as a porogen. Implants with controlled porosity and pore interconnectivity were fabricated by varying the ratio of hydrogel:polymer and the amount of carboxymethylcellulose within the hydrogel. The in vivo tissue response to the implants was observed by implanting solid, low-porosity, and high-porosity implants (n = 6) within a nonhealing rabbit mandibular defect that included an oral mucosal defect to allow open communication between the oral cavity and the mandibular defect. Oral mucosal wound healing was observed after 12 weeks and was complete in 3/6 defects filled with solid PMMA implants and 5/6 defects filled with either a low- or high-porosity PMMA implant. The tissue response around and within the pores of the two formulations of porous implants tested in vivo was characterized, with the low-porosity implants surrounded by a minimal but well-formed fibrous capsule in contrast to the high-porosity implants, which were surrounded and invaded by almost exclusively inflammatory tissue. On the basis of these results, PMMA implants with limited porosity hold promise for temporary implantation and space maintenance within clean/contaminated bone defects. PMID:20524844
Ultrasoft microwire neural electrodes improve chronic tissue integration
Du, Zhanhong Jeff; Kolarcik, Christi L.; Kozai, Takashi D.Y.; Luebben, Silvia D.; Sapp, Shawn A.; Zheng, Xin Sally; Nabity, James A.; Cui, X. Tracy
2017-01-01
Chronically implanted neural multi-electrode arrays (MEA) are an essential technology for recording electrical signals from neurons and/or modulating neural activity through stimulation. However, current MEAs, regardless of the type, elicit an inflammatory response that ultimately leads to device failure. Traditionally, rigid materials like tungsten and silicon have been employed to interface with the relatively soft neural tissue. The large stiffness mismatch is thought to exacerbate the inflammatory response. In order to minimize the disparity between the device and the brain, we fabricated novel ultrasoft electrodes consisting of elastomers and conducting polymers with mechanical properties much more similar to those of brain tissue than previous neural implants. In this study, these ultrasoft microelectrodes were inserted and released using a stainless steel shuttle with polyethyleneglycol (PEG) glue. The implanted microwires showed functionality in acute neural stimulation. When implanted for 1 or 8 weeks, the novel soft implants demonstrated significantly reduced inflammatory tissue response at week 8 compared to tungsten wires of similar dimension and surface chemistry. Furthermore, a higher degree of cell body distortion was found next to the tungsten implants compared to the polymer implants. Our results support the use of these novel ultrasoft electrodes for long term neural implants. PMID:28185910
Mertens, Christian; Freudlsperger, Christian; Bodem, Jens; Engel, Michael; Hoffmann, Jürgen; Freier, Kolja
2016-11-01
Treatment of post-resective defects of the maxilla can be challenging and usually requires dental obturation or microvascular reconstruction. As compared to soft-tissue microvascular grafts, bone reconstruction can additionally allow for facial support and retention of dental implants. The aim of this study was to evaluate scapular tip grafts with respect to their applicability for maxillary reconstruction and their potential to retain dental implants for later dental rehabilitation. In this retrospective study, 14 patients with hemimaxillectomy defects were reconstructed with free scapular tip grafts, oriented horizontally, to rebuild the palate and alveolar ridge. After bone healing, three-dimensional virtual implant planning was performed, and a radiographic guide was fabricated to enable implant placement in the optimal anatomic and prosthetic position. All patients' mastication and speech were evaluated, along with the extent of defect closure, suitability of the graft sites for implant placement, and soft-tissue stability. Pre- and postsurgical radiographs were also evaluated. A good postoperative outcome was achieved in all patients, with complete closure of maxillary defects that were class II, according to the system of Brown and Shaw. Additional bone augmentation was necessary in two patients in order to increase vertical bone height. Patients were subsequently treated with 50 dental implants to retain dental prostheses. In all cases, additional soft-tissue surgery was necessary to achieve a long-term stable periimplant situation. No implants were lost during the mean observation period of 34 months. Due to its specific form, the scapular tip graft is well suited to reconstruct the palate and maxillary alveolar ridge and to enable subsequent implant-retained rehabilitation. Due to the limited bone volume, an accurate three-dimensional graft orientation is essential. Furthermore, most cases require additional soft-tissue surgery to achieve a long-term stable periimplant situation. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Chordekar, Shai; Perez, Ronen; Adelman, Cahtia; Sohmer, Haim; Kishon-Rabin, Liat
2018-04-03
Hearing can be elicited in response to bone as well as soft-tissue stimulation. However, the underlying mechanism of soft-tissue stimulation is under debate. It has been hypothesized that if skull vibrations were the underlying mechanism of hearing in response to soft-tissue stimulation, then skull vibrations would be associated with hearing thresholds. However, if skull vibrations were not associated with hearing thresholds, an alternative mechanism is involved. In the present study, both skull vibrations and hearing thresholds were assessed in the same participants in response to bone (mastoid) and soft-tissue (neck) stimulation. The experimental group included five hearing-impaired adults in whom a bone-anchored hearing aid was implanted due to conductive or mixed hearing loss. Because the implant is exposed above the skin and has become an integral part of the temporal bone, vibration of the implant represented skull vibrations. To ensure that middle-ear pathologies of the experimental group did not affect overall results, hearing thresholds were also obtained in 10 participants with normal hearing in response to stimulation at the same sites. We found that the magnitude of the bone vibrations initiated by the stimulation at the two sites (neck and mastoid) detected by the laser Doppler vibrometer on the bone-anchored implant were linearly related to stimulus intensity. It was therefore possible to extrapolate the vibration magnitudes at low-intensity stimulation, where poor signal-to-noise ratio limited actual recordings. It was found that the vibration magnitude differences (between soft-tissue and bone stimulation) were not different than the hearing threshold differences at the tested frequencies. Results of the present study suggest that bone vibration magnitude differences can adequately explain hearing threshold differences and are likely to be responsible for the hearing sensation. Thus, the present results support the idea that bone and soft-tissue conduction could share the same underlying mechanism, namely the induction of bone vibrations. Studies with the present methodology should be continued in future work in order to obtain further insight into the underlying mechanism of activation of the hearing system. Copyright © 2018 Elsevier B.V. All rights reserved.
Naenni, Nadja; Bienz, Stefan P; Benic, Goran I; Jung, Ronald E; Hämmerle, Christoph H F; Thoma, Daniel S
2018-04-01
The objective of this study was to test whether or not soft tissue augmentation with a volume-stable collagen matrix (VCMX) leads to similar volume gain around dental implants compared to autogenous subepithelial connective tissue graft (SCTG). In 12 adult beagle dogs, immediate implants were placed with simultaneous guided bone regeneration. After 25-45 weeks, soft tissue augmentation was randomly performed using VCMX, SCTG, or a sham-operated control. Impressions were taken pre-op and post-op (tissue augmentation) and again at sacrifice after healing periods of 4, 8, and 24 weeks. They were then digitized to allow for superimposition. Values of linear and volumetric changes were calculated. The median increase (pre-op to post-op) in buccal volume measured 0.92 mm for VCMX, 1.47 mm for SCTG, and 0.24 mm for SH. The values (pre-op to sacrifice) were - 0.25 mm for VCMX, 0.52 mm for SCTG, and - 0.06 mm for group SH. The median ridge width 2 mm below the crest measured - 0.26 mm for VCMX, 0.53 mm for SCTG, and - 0.15 mm for SH (pre-op to sacrifice). Volume augmentation using VCMX and SCTG resulted in an increase in ridge dimension (pre- to post-op). During the follow-up, the volume decreased in all three groups to a level close to the situation prior to surgery. Soft tissue volume augmentation around dental implants is usually performed using the patient's own tissue. This therapy is associated with an increased morbidity due to a second surgical site. Soft tissue volume at implant sites can be augmented using VCMX and SCTG. The gain on top of the ridge appears not to be stable during the follow-up in both groups.
Implementing Capsule Representation in a Total Hip Dislocation Finite Element Model
Stewart, Kristofer J; Pedersen, Douglas R; Callaghan, John J; Brown, Thomas D
2004-01-01
Previously validated hardware-only finite element models of THA dislocation have clarified how various component design and surgical placement variables contribute to resisting the propensity for implant dislocation. This body of work has now been enhanced with the incorporation of experimentally based capsule representation, and with anatomic bone structures. The current form of this finite element model provides for large deformation multi-body contact (including capsule wrap-around on bone and/or implant), large displacement interfacial sliding, and large deformation (hyperelastic) capsule representation. In addition, the modular nature of this model now allows for rapid incorporation of current or future total hip implant designs, accepts complex multi-axial physiologic motion inputs, and outputs case-specific component/bone/soft-tissue impingement events. This soft-tissue-augmented finite element model is being used to investigate the performance of various implant designs for a range of clinically-representative soft tissue integrities and surgical techniques. Preliminary results show that capsule enhancement makes a substantial difference in stability, compared to an otherwise identical hardware-only model. This model is intended to help put implant design and surgical technique decisions on a firmer scientific basis, in terms of reducing the likelihood of dislocation. PMID:15296198
Yan, Qi; Xiao, Li-Qun; Su, Mei-Ying; Mei, Yan; Shi, Bin
This systematic review aimed to compare immediate protocols with conventional protocols of single-tooth implants in terms of changes in the surrounding hard and soft tissue in the esthetic area. Electronic and manual searches were performed in PubMed, EMBASE, Cochrane, and other data systems for research articles published between January 2001 and December 2014. Only randomized controlled trials (RCTs) reporting on hard and or soft tissue characteristics following a single-tooth implant were included. Based on the protocol used in each study, the included studies were categorized into three groups to assess the relationships between the factors and related esthetic indexes. Variables such as marginal bone level changes (mesial, distal, and mean bone level), peri-implant soft tissue changes (papilla level, midbuccal mucosa, and probing depth), and other esthetic indices were taken into consideration. The data were analyzed using RevMan version 5.3, Stata 12, and GRADEpro 3.6.1 software. A total of 13 RCTs met the inclusion criteria. Four studies examined immediate implant placement, five studies examined immediate implant restoration, and four studies examined immediate loading. Comparing the bone level changes following immediate and conventional restoration, no significant differences were found in the bone level of the mesial site (standard mean difference [SMD] = -0.04 mm; 95% confidence interval [CI]: -0.25 to 0.17 mm), the distal site (SMD = -0.15 mm; 95% CI: -0.38 to 0.09 mm), and the mean bone level changes (SMD = 0.05 mm; 95% CI: -0.18 to 0.27 mm). The difference in the marginal bone level changes between immediate and conventional loading was also not statistically significant (SMD = -0.05 mm; 95% CI: -0.15 to 0.06 mm for the mesial site and SMD = -0.02 mm; 95% CI: -0.09 to 0.05 mm for the distal site). Soft tissue changes following immediate and conventional restoration reported no significant differences in the papillae level of the mesial site (SMD = 0.18 mm; 95% CI: -0.00 to 0.37 mm), the papillae level of the distal site (SMD = -0.12 mm; 95% CI: -0.34 to 0.09 mm), and the midbuccal mucosa (SMD = -0.22 mm; 95% CI: -1.29 to 0.85 mm). Within the limitations, it can be concluded that immediately placed, restored, or loaded single-tooth implants in the esthetic zone result in similar hard and soft tissue changes compared with conventional protocols.
French, David; Cochran, David L; Ofec, Ronen
The purpose of this report is to describe the crestal bone level (CBL) around implants of various designs, describe the peri-implant soft tissue condition, and evaluate the relationship between the two over time. This retrospective cohort study reports on 2,060 patients with 4,591 implants evaluated after 3 months; 1, 3, 5, and 7 years; and up to 10 years. Periapical radiographs were used to evaluate changes in CBL. The peri-implant soft tissue was evaluated using a modified Bleeding Index termed the Implant Mucosal Index (IMI) where: 0 = no bleeding; 1 = minimal, single-point bleeding; 2 = moderate, multipoint bleeding; 3 = profuse, multipoint bleeding; and 4 = suppuration. At 3 months, the mean CBL was 0.06 ± 0.22 mm; by 8 to 10 years, it had increased to 0.44 ± 0.81 mm. The median CBL remained stable throughout the study at < 0.1 mm. At 8 to 10 years, 15% of implants exhibited a CBL > 1.02 mm, and 5% exhibited a CBL > 2.28 mm. More than 50% of patients experienced some bleeding, as seen by an IMI ≥ 1 during follow-up. A positive correlation was found between IMI and CBL, as shown by a mean CBL after 4 years of 0.33 mm, 0.71 mm, and 1.52 mm for IMI = 2, 3, and 4, respectively. One exception was between IMI = 0 and IMI = 1, where no significant difference was found and bone loss was minimal. Bone loss, as measured by changes in CBL during the first 10 years of implant life spans, was minimal for most implants. Nevertheless, it is not unusual to observe implants with advanced bone loss. The soft tissue condition is a good indicator of bone loss. Time alone and minimal bleeding did not correlate with bone loss, but care should be taken for implants with profuse bleeding or suppuration.
Le, Bach; Borzabadi-Farahani, Ali; Nielsen, Brady
2016-08-01
Soft tissue augmentation procedures are often performed to correct gingival recession on the facial aspects of implants in the esthetic zone. This retrospective clinical case series reports on the use of guided bone regeneration (GBR) and a coronal advancement flap with a resorbable membrane and allograft. We analyzed the records of 14 patients (7 men and 7 women) with a mean age of 36.78 years (SD, 13.9 years) who were treated for soft tissue recessions around implant-supported restorations in the maxillary central or lateral incisor location. Implant diameters ranged from 3.3 to 4.7 mm. All patients had bone loss confined to the labial surface of the implant. A solvent-dehydrated particulate mineralized allograft (Puros Cancellous Bone Allograft; Zimmer Biomet Dental, Palm Beach Gardens, FL) and a resorbable membrane (CopiOs Pericardium; Zimmer Biomet Dental) were used in a GBR surgical procedure in combination with a roughened titanium tenting screw placed 3 to 4 mm below the implant platform to restore unesthetic defects in the anterior maxilla. All postoperative tissue changes from their preoperative states were statistically significant (P < .05, Wilcoxon signed rank test). Mean preoperative crestal bone thickness (measured 2 mm from crest) and mid-implant buccal bone thickness increased by 1.84 mm (SD, 0.89 mm; 95% confidence interval [CI], 1.32 to 2.35 mm) and 2.07 mm (SD, 0.81 mm; 95% CI, 1.60 to 2.53 mm), respectively, approximately 1 year after treatment (P < .001). Significant mean increases of 1.28 mm (SD, 0.53 mm; 95% CI, 0.97 to 1.58 mm), 1.29 mm (SD, 0.81 mm; 95% CI, 0.82 to 1.75 mm) and 1.23 mm (SD, 0.53 mm; 95% CI, 0.92 to 1.53 mm) also were noted in soft tissue thickness, keratinized tissue width, and gingival height, respectively (P < .001). Use of the allograft and xenogeneic membrane effectively increased alveolar hard and soft tissue dimensions in the esthetic zone of the anterior maxilla. Future prospective clinical trials with a control group are needed to compare this technique with conventional methods such as connective tissue graft. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Zhan, Weiqing; Tan, Shaun S; Lu, Feng
2016-08-01
In reconstructive surgery, there is a clinical need for adequate implants to repair soft tissue defects caused by traumatic injury, tumor resection, or congenital abnormalities. Adipose tissue engineering may provide answers to this increasing demand. This study comprehensively reviews current approaches to adipose tissue engineering, detailing different cell carriers under investigation, with a special focus on the application of adipose-derived stem cells (ASCs). ASCs act as building blocks for new tissue growth and as modulators of the host response. Recent studies have also demonstrated that the implantation of a hollow protected chamber, combined with a vascular pedicle within the fat flaps provides blood supply and enables the growth of large-volume of engineered soft tissue. Conceptually, it would be of value to co-regulate this unique chamber model with adipose-derived stem cells to obtain a greater volume of soft tissue constructs for clinical use. Our review provides a cogent update on these advances and details the generation of possible fat substitutes.
Schwarz, Frank; Mihatovic, Ilja; Shirakata, Yoshinori; Becker, Jürgen; Bosshardt, Dieter; Sculean, Anton
2014-01-01
To histologically assess the effectiveness of a porcine-derived collagen matrix (CM) and a subepithelial connective tissue graft (CTG) for the coverage of single mucosal recessions at osseointegrated dental implants. Chronic-type mucosal Miller Class I-like recessions (mean clinical defect height: 0.67 ± 0.33-1.16 ± 0.19 mm) were established at the buccal aspect of titanium implants with platform switch in six beagle dogs. The defects were randomly allocated to either (1) coronally advanced flap surgery (CAF) + CM, (2) CAF + CTG or (3) CAF alone. At 12 weeks, histomorphometrical measurements were made (e.g.) between the implant shoulder (IS) and the mucosal margin (PM) and IS and the outer contour of the adjacent soft tissue (mucosal thickness [MT]). All treatment procedures investigated were associated with an almost complete soft tissue coverage of the defect area (i.e. coronal positioning of PM relative to IS). Mean IS-PM and MT values tended to be increased in both CAF + CM (1.04 ± 0.74 mm/0.71 ± 0.55 mm) and CAF + CTG (0.88 ± 1.23 mm/0.62 ± 0.66 mm) groups when compared with CAF (0.16 ± 0.28 mm/0.34 ± 0.23 mm) alone. These differences, however, did not reach statistical significance. Within the limits of this pilot study, it was concluded that all treatment procedures investigated were effective in covering soft tissue recessions at titanium implants. © 2012 John Wiley & Sons A/S.
Buccal bone deficiency in fresh extraction sockets: a prospective single cohort study.
Barone, Antonio; Ricci, Massimiliano; Romanos, Georgios E; Tonelli, Paolo; Alfonsi, Fortunato; Covani, Ugo
2015-07-01
The purpose of this prospective single cohort study was to evaluate the use of xenograft and collagen membranes in treating full or partial buccal bone defects of fresh extraction sockets in the esthetic zone. Thirty-three patients requiring tooth extraction in the anterior maxillary area and showing a complete or partial buccal bone plate deficiency (more than 2 mm) were consecutively enrolled and treated. Corticocancellous porcine bone and platelet-rich fibrin (PRF) with a collagen membrane were used to graft the extraction sockets, and the membranes were left exposed to the oral cavity with a secondary soft tissue healing. The outcome variables were as follows: width of keratinized mucosa, facial soft tissue levels, clinical bone changes (measured with a clinical splint), implant and prosthesis failures, and peri-implant marginal bone changes. All treated sites allowed the placement of implants; the width of keratinized mucosa at the mid-facial aspect showed an increase of 2.3 mm 5 months after the grafting procedure, and its value was 3.2 ± 0.6 mm at 1-year follow-up. The mean values of the facial soft tissue level indicated an increase over time. The bone level showed an improvement of 0.8 ± 0.1 mm and 0.7 ± 0.1 mm at mesial and distal sites, respectively, when compared to the baseline measurements. Finally, in the palatal area, no bone changes were observed. No implant failed during the entire observation period. Findings from this study showed that xenograft and PRF, used for ridge preservation of the extraction sockets with buccal bone plate dehiscence in the esthetic zone, can be considered effective in repairing bone defects before implant placement. The secondary soft tissue healing over the grafted sockets did not compromise bone formation; moreover, the soft tissue level and the width of keratinized gingiva showed a significant improvement over time. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Simulation of peri-implant bone healing due to immediate loading in dental implant treatments.
Chou, Hsuan-Yu; Müftü, Sinan
2013-03-15
The goal of this work was to investigate the role of immediate loading on the peri-implant bone healing in dental implant treatments. A mechano-regulatory tissue differentiation model that takes into account the stimuli through the solid and the fluid components of the healing tissue, and the diffusion of pluripotent stem cells into the healing callus was used. A two-dimensional axisymmetric model consisting of a dental implant, the healing callus tissue and the host bone tissue was constructed for the finite element analysis. Poroelastic material properties were assigned to the healing callus and the bone tissue. The effects of micro-motion, healing callus size, and implant thread design on the length of the bone-to-implant contact (BIC) and the bone volume (BV) formed in the healing callus were investigated. In general, the analysis predicted formation of a continuous layer of soft tissue along the faces of the implant which are parallel to the loading direction. This was predicted to be correlated with the high levels of distortional strain transferred through the solid component of the stimulus. It was also predicted that the external threads on the implant, redistribute the interfacial load, thus help reduce the high distortional stimulus and also help the cells to differentiate to bone tissue. In addition, the region underneath the implant apex was predicted to experience high fluid stimulus that results in the development of soft tissue. The relationship between the variables considered in this study and the outcome measures, BV and BIC, was found to be highly nonlinear. A three-way analysis of variance (ANOVA) of the results was conducted and it showed that micro-motion presents the largest hindrance to bone formation during healing. Copyright © 2013 Elsevier Ltd. All rights reserved.
Zeltner, Marco; Jung, Ronald E; Hämmerle, Christoph H F; Hüsler, Jürg; Thoma, Daniel S
2017-04-01
To test whether or not the use of a volume-stable collagen matrix (VCMX) results in soft tissue volume increase at implant sites non-inferior to an autogenous subepithelial connective tissue graft (SCTG). In 20 patients, soft tissue augmentation at implant sites was performed using VCMX or SCTG. Casts obtained prior to augmentation (BL), at 30 (FU-30) and 90 days (FU-90) were digitized and transferred to stereolithography (STL) files. BL, FU-30 and FU-90 STL files were superimposed and linear volumetric changes evaluated in crestal and buccal regions of interest (ROI). Descriptive analysis was computed for both groups and a test for non-inferiority was performed. The median linear changes from BL to FU-90 in the crestal ROI amounted to 0.175 mm (0.06; 0.51) for VCMX (p = 0.002 over time) and to 0.51 mm (0.23; 0.94) for SCTG (p = 0.129). The differences between the two groups were not significant (p = 0.287). The respective values in the buccal ROI were 0.59 mm (0.26; 1.06) for VCMX (p = 0.002) and 0.94 mm (0.66; 1.13) for SCTG (p = 0.004). The differences between the two groups were not significant (crestal: p = 0.287; buccal: p = 0.534). Non-inferiority could be concluded for VCMX compared to SCTG for both ROI. VCMX and SCTG can be used for soft tissue augmentation at implant sites resulting in an at least short-term increase in volume. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Sauerbier, M; Hahn, M E; Fujita, M; Neale, P G; Germann, G; An, K N; Berger, R A
2002-08-01
The most common method of treating the arthrotic distal radioulnar joint (DRUJ) is resection of the entire ulnar head (Darrach procedure). Complications related to instability of the distal forearm resulting from loss of the ulnar head are usually manifested by pain and weak grip strength and have remained the drawbacks of this procedure. In an attempt to mechanically stabilize the distal forearm, an endoprosthesis was developed to replace the ulnar head after Darrach resection. The purpose of this study was to: 1) evaluate the dynamic effects of the Darrach procedure on radioulnar convergence; and 2) evaluate the mechanical efficacy of two soft tissue stabilizing techniques (Pronator quadratus advancement flap and ECU/FCU tenodesis) for the unstable distal ulnar stump and 3) the stability after the implantation of an ulnar head endoprosthesis following a Darrach resection on radioulnar convergence. With a dynamic PC-controled forearm simulator the rotation of 7 fresh-frozen cadaver upper extremities was actively and passively performed while loading relevant muscles. Resultant total forearm torque and the 3-dimensional kinematics of the ulna, radius and third metacarpal were recorded simultaneously. The implantation of the ulnar head endoprosthesis effectively restored the stability of the DRUJ. There were significantly better results after the implantation of the prosthesis compared with the Darrach and the soft tissue stabilization procedures. This study provides laboratory validity to the option of implanting an ulnar head endoprosthesis as an attempt to stabilize the distal forearm after Darrach resection in lieu of performing soft tissue stabilization techniques.
Peri-implant esthetics assessment and management
Balasubramaniam, Aarthi S.; Raja, Sunitha V.; Thomas, Libby John
2013-01-01
Providing an esthetic restoration in the anterior region of the mouth has been the basis of peri-implant esthetics. To achieve optimal esthetics, in implant supported restorations, various patient and tooth related factors have to be taken into consideration. Peri-implant plastic surgery has been adopted to improve the soft tissue and hard tissue profiles, during and after implant placement. The various factors and the procedures related to enhancement of peri-implant esthetics have been discussed in this review article. PMID:23878557
Color Analysis of Periimplant Soft Tissues Focusing on Implant System: A Case Series.
Varoni, Elena M; Moltrasio, Giuseppe; Gargano, Marco; Ludwig, Nicola; Lodi, Giovanni; Scaringi, Riccardo
2017-04-01
To assess the impact of implant system on color harmonization of periimplant mucosa. In this case series, color of periimplant mucosa was compared with color of natural tooth gingiva. Seventeen intercanine implants were analyzed (11 bone level [BL], 6 tissue level [TL] implants). Colorimetric data, at 2, 4, and 6 mm from gingival margin, were collected through fiber optics reflectance spectroscopy, and color differences calculated as ΔE. Dentists, dental students, and lay people, in blind, performed an additional visual color analysis on clinical images. Independently from implant system, the color of periimplant mucosa was significantly different from gingiva (ΔE = 8.2 ± 0.7), resulting darker at L* comparison (P ≤ 0.05). TL periimplant mucosa showed higher ΔE than BL (9.0 ± 1.0 vs 6.6 ± 0.8, respectively; P ≤ 0.05). Observers correctly identified where the implant was placed in about half of the cases, with no significant difference between implant systems. Within the limitations of this study, the color of periimplant soft tissues appears different from gingiva, at spectroscopic analysis. Color discrepancy results higher in the presence of TL implants than in BL implants, although the difference may not be clinically significant.
Implant site development by orthodontic forced extraction: a preliminary study.
Amato, Francesco; Mirabella, A Davide; Macca, Ugo; Tarnow, Dennis P
2012-01-01
To evaluate the soft and hard tissue response to orthodontic implant site development (OISD) (ie, forced extraction), to measure the amount of tissue that was regenerated and its relationship to the amount of orthodontic vertical tooth movement, to evaluate the tissue response in teeth with different degrees of periodontal attachment loss, to understand the limits of OISD, and to evaluate the implant survival rate. A total of 32 hopeless teeth were treated with OISD, and 27 implants were placed in 13 patients consecutively. The level of periodontal attachment on the teeth to be extracted, amount of augmented alveolar bone, changes in soft tissue volume, and the rate of orthodontic tooth movement were recorded. Mean values after OISD were as follows: orthodontic extrusive movement, 6.2 ± 1.4 mm; bone augmentation, 4 ± 1.4 mm; coronal movement of the gingival margin, 3.9 ± 1.5 mm; coronal movement of the mucogingival junction, 2.1 ± 1.3 mm; keratinized gingival augmentation, 1.8 ± 1.1 mm; gingival thickness (buccolingual dimension) augmentation, 0.7 ± 0.4 mm; recession, 1.8 ± 1.2 mm; bone augmentation/orthodontic movement ratio (efficacy), 68.9% ± 17.3%; gingival augmentation/orthodontic movement ratio (efficacy), 65.2% ± 19.9%; and pocket depth reduction, 1.8 ± 0.9 mm. The implant survival rate was 96.3%. OISD was a viable treatment for these hopeless teeth to regenerate hard and soft tissues. Its efficacy was about 70% for bone regeneration and 60% for gingival augmentation. The residual attachment level on the tooth was not a limitation. OISD might be a valuable treatment option to regenerate tissues for implant site development in patients in need of conventional orthodontic therapy.
Paolone, Maria Giacinta; Kaitsas, Roberto
2018-06-01
Orthodontics is a periodontal treatment. "Guided orthodontic regeneration" (GOR) procedures use orthodontic movements in perio-restorative patients. The GOR technique includes a guided orthodontic "soft tissue" regeneration (GOTR) and a guided orthodontic "bone" regeneration (GOBR) with a plastic soft tissue approach and a regenerating reality. The increased amount of soft tissue gained with orthodontic movement can be used for subsequent periodontal regenerative techniques. The increased amount of bone can as well improve primary implant stability and, eventually, simplify a GTR technique to regenerate soft tissues, to restore tooth with external resorption in aesthetic zone or to extract a tooth to create new hard-soft tissue for adjacent teeth. Copyright © 2018. Published by Elsevier Masson SAS.
BASSI, M. ANDREASI; ANDRISANI, C.; LICO, S.; SILVESTRE, F.; GARGARI, M.; ARCURI, C.
2016-01-01
SUMMARY Purpose The aim of this article is to make a comparative assessment between the modification of the soft-tissue profile, around the healing cap screws (HCSs), following both the traditional flapless surgery (TFS) and a new modified flapless surgery, named Modified Connective Tissue Punch (MCTP) technique. Materials and methods 8 patients (3M and 5F) (mean age 54.25±11.247 years) were enrolled in this study. Sixteen two-piece implants were placed on upper jaws, 2 for each patient, 8 with TFS and 8 with MCTP technique. In each patient the implants were placed in edentulous areas, of 2 or 3 adjacent teeth long. MCTP technique was performed on the front implant site (FIS) while the TFS was performed on the rear implant site (RIS). All implants were inserted and covered with healing cap screws (HCSs). Alginate impressions were carried out at the moment of the surgery, at 1 month and 4 months post-operative. Plaster models were poured and subsequently digitally scanned, in order to measure the distance between the gingival outline and the free margin of the HCS. The recorded values were analyzed with the ANOVA test. Results The use of MTCP technique, in comparison to TFS, showed a significative better outcome, in terms of vertical increments, of gingiva, on the VS toward the HCSs, during the entire observation period (p = 0.000 for all). Conclusion The Authors recommend the use of MCTP technique for a better vestibular soft tissue outcome in flapless implant surgery. PMID:28042442
[Treatment of adult bimaxillary arch protrusion with micro-implant anchorage].
Chen, Cheng; Zhang, Xiao-Rong
2015-02-01
In this study, micro-implants were used in 15 adult patients with mild and moderate bimaxillary arch protrusion or crowding. Cephalometric analysis was used to analyze hard and soft-tissues change before and after treatment, with the aim to investigate the effects of treatment on adult bimaxillary arch protrusion with micro-implant anchorage. Fifteen adult patients with mild and moderate bimaxillary arch protrusion were selected in this study. Micro-implants were inserted into the zygomaticoalveolar ridge of maxilla and the external oblique line of mandible. A NiTi coil spring was attached to the micro-implant to drag the whole upper and lower dentition for distal movement. Cephalometrics were taken before and after treatment, and the changes of soft and hard-tissue profile were studied. SPSS13.0 software package was used to analyze the data. (1)Sixty micro-implants remained stable.(2)SNA, SNB had no significant changes (P>0.05), and the relationship between the maxilla and the mandible did not change significantly. U1/NA, U1-NA, L1/NB, L1-NB and U1/L1 changes in hard tissue had significant difference in cephalometric measurement (P<0.05). The upper and lower anterior teeth were more retrusive, and the tipping of incisor decreased significantly.(3)Cephalometric analysis showed that lateral appearance improved and soft tissue cephalometric-related measurements such as Cm-Sn-UL,LL-B'-Pos increased significantly (P<0.01). (4)Molars and incisors acquired distal movement. Micro-implant can provide not only excellent skeletal anchorage but also a novel way to distalize the whole dentition efficiently.
Tonetti, Maurizio S; Jepsen, Søren
2014-04-01
The scope of the discussions of this consensus report was to assess the strength of the scientific evidence and make clinical and research recommendations for surgical interventions to cover exposed root surfaces and enhance soft tissues at implants. Discussions were informed by three systematic reviews covering single recessions, multiple recessions and soft-tissue deficiencies at implants. The strength of the evidence was assessed using a modification in GRADE. The group also emphasized the need to report the experience of the surgeon and the performance of the control intervention (CONSORT guidelines for non-pharmacological treatment). A moderate strength of evidence supported the following statements for single (moderately deep, mostly maxillary) recessions without inter-dental attachment loss: (i) The addition of a connective tissue graft (CTG) improved outcomes of coronally advanced flaps (CAF). (ii) The addition of enamel matrix derivative (EMD) improved the outcomes of CAF. For multiple recessions, preliminary data indicate that flaps specifically designed to treat this condition are worthy of additional attention. Emerging data indicate that it is possible to obtain complete root coverage at sites with some inter-dental attachment loss. With regards to soft-tissue deficiencies at implants, several procedures are available, but great heterogeneity among studies does not allow drawing conclusions at this time. The group highlighted that periodontal plastic procedures are complex, technique-sensitive interventions that require advanced skills and expertise. At single recessions, the addition of autologous CTG or EMD under CAF improves complete root coverage and may be considered the procedure of choice at maxillary anterior and premolar teeth. The adjunctive benefit needs to be put in the context of increased morbidity of the donor area or increased cost. Additional research is needed to: (i) assess the role of alternatives to autologous soft-tissue grafting in combination with CAF; (ii) identify the optimal surgical design and the need for additional soft-tissue grafting (or alternatives) at multiple recessions, recessions with inter-dental attachment loss and soft-tissue deficiencies at implants. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Implant-Related Gingival Recession: Pilot Case Series Presents Novel Technique and Scoring Template.
El Askary, Abd El Salam; Ghallab, Noha A; Tan, Shuh-Chern; Rosen, Paul S; Shawkat, Ahmad
2016-07-01
This article introduces a novel protocol for the predictable treatment of Class II division 2 implantrelated gingival recession and presents an innovative acrylic template for scoring the peri-implant soft-tissue gain, used before and after treatment. Ten patients with Class II division 2 single-implant-related gingival recession received combined double-papillary flap approximation and rotated subepithelial connective tissue grafting from the palate, along with any preferred optimal grafting technique that suits the type of preexisting defect. Clinical gingival recession was recorded using a scoring template at 4, 6, and 9 months postoperatively. At the end of the 9-month follow-up period, 80% of the cases showed improved soft-tissue coverage; two patients showed significant wound complications that were related to poor home-care measures. The scoring method used can be considered a diagnostic and prognostic tool for better understanding of implant-related gingival recession.
Fiber-reinforced scaffolds in soft tissue engineering
Wang, Wei; Fan, Yubo; Wang, Xiumei; Watari, Fumio
2017-01-01
Abstract Soft tissue engineering has been developed as a new strategy for repairing damaged or diseased soft tissues and organs to overcome the limitations of current therapies. Since most of soft tissues in the human body are usually supported by collagen fibers to form a three-dimensional microstructure, fiber-reinforced scaffolds have the advantage to mimic the structure, mechanical and biological environment of natural soft tissues, which benefits for their regeneration and remodeling. This article reviews and discusses the latest research advances on design and manufacture of novel fiber-reinforced scaffolds for soft tissue repair and how fiber addition affects their structural characteristics, mechanical strength and biological activities in vitro and in vivo. In general, the concept of fiber-reinforced scaffolds with adjustable microstructures, mechanical properties and degradation rates can provide an effective platform and promising method for developing satisfactory biomechanically functional implantations for soft tissue engineering or regenerative medicine. PMID:28798872
Lago, Laura; da Silva, Luis; Gude, Francisco; Rilo, Benito
The aim of this prospective study was to evaluate radiographic levels of peri-implant bone crest as well as soft tissue response, papilla height, and buccal mucosa recession, in bone-level implants restored with platform switching after 1-year and 5-year follow-ups. This prospective study called for the placement of 59 implants to obtain a target of 90% power. To compensate for possible dropouts, the sample size was adjusted to 67 implants. To assess marginal bone level changes, periapical radiographs were taken at baseline, 1 year, and 5 years after the definitive restorations. Peri-implant soft tissue modifications were evaluated by performing a photographic sequence at 15 days, 1 year, and 5 years after implant restoration. Parameters measured were: (1) distance from the tip of the papilla to the contact point and (2) apicocoronal crown length. A one-way analysis of variance (ANOVA rank test) was used to compare quantitative data among the three time points studied. Mean marginal bone level changes were as follows: -0.06 ± 0.32 mm from baseline to 1 year, -0.23 ± 0.38 mm from 1 to 5 years, and -0.28 ± 0.45 mm from baseline to 5 years. In bone-level outcomes, no statistically significant differences were found between baseline and 1 year, while the mean differences between 1 and 5 years and baseline and 5 years showed statistically significant differences. In the soft tissue analysis, the distance from the tip of the papilla to the contact point showed the following values: baseline, 2.08 mm; 1 year, 1.54 mm; 5 years, 1.31 mm. No statistically significant differences were found between baseline and 1 year, whereas statistically significant differences between 1 and 5 years and baseline and 5 years were found. Apicocoronal crown length measurements showed the following values: baseline, 9.44 mm; 1 year, 9.28 mm; 5 years, 9.81 mm. No significant differences were found between times studied. This prospective clinical study of 67 bone-level implants restored according to the platform-switching concept reported that radiographic levels of peri-implant bone crest were statistically significant between 1 and 5 years and baseline and 5 years. For the soft tissue response, the greatest reduction in the distance from the papilla to the contact point from 1 to 5 years and baseline to 5 years was observed. No significant differences were shown in the buccal margin.
Prostate seed implant quality assessment using MR and CT image fusion.
Amdur, R J; Gladstone, D; Leopold, K A; Harris, R D
1999-01-01
After a seed implant of the prostate, computerized tomography (CT) is ideal for determining seed distribution but soft tissue anatomy is frequently not well visualized. Magnetic resonance (MR) images soft tissue anatomy well but seed visualization is problematic. We describe a method of fusing CT and MR images to exploit the advantages of both of these modalities when assessing the quality of a prostate seed implant. Eleven consecutive prostate seed implant patients were imaged with axial MR and CT scans. MR and CT images were fused in three dimensions using the Pinnacle 3.0 version of the ADAC treatment planning system. The urethra and bladder base were used to "line up" MR and CT image sets during image fusion. Alignment was accomplished using translation and rotation in the three ortho-normal planes. Accuracy of image fusion was evaluated by calculating the maximum deviation in millimeters between the center of the urethra on axial MR versus CT images. Implant quality was determined by comparing dosimetric results to previously set parameters. Image fusion was performed with a high degree of accuracy. When lining up the urethra and base of bladder, the maximum difference in axial position of the urethra between MR and CT averaged 2.5 mm (range 1.3-4.0 mm, SD 0.9 mm). By projecting CT-derived dose distributions over MR images of soft tissue structures, qualitative and quantitative evaluation of implant quality is straightforward. The image-fusion process we describe provides a sophisticated way of assessing the quality of a prostate seed implant. Commercial software makes the process time-efficient and available to any clinical practice with a high-quality treatment planning system. While we use MR to image soft tissue structures, the process could be used with any imaging modality that is able to visualize the prostatic urethra (e.g., ultrasound).
Caneva, Marco; Botticelli, Daniele; Morelli, Fabrizio; Cesaretti, Gianfranco; Beolchini, Marco; Lang, Niklaus P
2012-07-01
To evaluate the soft tissue and the dimensional changes of the alveolar bony crest at sites where deproteinized bovine bone mineral (DBBM) particles, concomitantly with the placement of a collagen membrane, were used at implants installed into sockets immediately after tooth extraction. The pulp tissue of the mesial roots of (3) P(3) was removed in six Labrador dogs, and the root canals were filled. Flaps were elevated bilaterally, the premolars hemi-sectioned, and the distal roots removed. Recipient sites were prepared in the distal alveolus, and implants were placed. At the test sites, DBBM particles were placed in the residual marginal defects concomitantly with the placement of a collagen membrane. No treatment augmentation was performed at the control sites. A non-submerged healing was allowed. Impressions were obtained at baseline and at the time of sacrifice performed 4 months after surgery. The cast models obtained were analyzed using an optical system to evaluate dimensional variations. Block sections of the implant sites were obtained for histological processing and soft tissue assessments. After 4 months of healing, no differences in soft tissue dimensions were found between the test and control sites based on the histological assessments. The location of the soft tissue at the buccal aspect was, however, more coronal at the test compared with the control sites (1.8 ± 0.8 and 0.9 ± 0.8 mm, respectively). At the three-dimensional evaluation, the margin of the soft tissues at the buccal aspect appeared to be located more apically and lingually. The vertical dislocation was 1 ± 0.6 and 2.7 ± 0.5 mm at the test and control sites, respectively. The area of the buccal shrinkage of the alveolar crest was significantly smaller at the test sites (5.9 ± 2.4 mm(2) ) compared with the control sites (11.5 ± 1.7 mm(2) ). The use of DBBM particles concomitantly with the application of a collagen membrane used at implants placed into sockets immediately after tooth extraction contributed to the preservation of the alveolar process. © 2011 John Wiley & Sons A/S.
Siciliano, V Iorio; Salvi, G E; Matarasso, S; Cafiero, C; Blasi, A; Lang, N P
2009-05-01
To assess soft tissues healing at immediate transmucosal implants placed into molar extraction sites with buccal self-contained dehiscences. For this 12-month controlled clinical trial, 15 subjects received immediate transmucosal tapered-effect (TE) implants placed in molar extraction sockets displaying a buccal bone dehiscence (test sites) with a height and a width of > or =3 mm, respectively. Peri-implant marginal defects were treated according to the principles of Guided Bone Regeneration (GBR) by means of deproteinized bovine bone mineral particles in conjunction with a bioresorbable collagen membrane. Fifteen subjects received implants in healed molar sites (control sites) with intact buccal alveolar walls following tooth extraction. In total, 30 TE implants with an endosseous diameter of 4.8 mm and a shoulder diameter of 6.5 mm were used. Flaps were repositioned and sutured, allowing non-submerged, transmucosal soft tissues healing. At the 12-month follow-up, pocket probing depths (PPD) and clinical attachment levels (CAL) were compared between implants placed in the test and the control sites, respectively. All subjects completed the 12-month follow-up period. All implants healed uneventfully, yielding a survival rate of 100%. After 12 months, statistically significantly higher (P<0.05) PPD and CAL values were recorded around implants placed in the test sites compared with those placed in the control sites. The findings of this controlled clinical trial showed that healing following immediate transmucosal implant installation in molar extraction sites with wide and shallow buccal dehiscences yielded less favorable outcomes compared with those of implants placed in healed sites, and resulted in lack of 'complete' osseointegration.
A Review of the Positive Influence of Crown Contours on Soft-Tissue Esthetics.
Kinsel, Richard P; Pope, Bryan I; Capoferri, Daniele
2015-05-01
Successful crown restorations duplicate the natural tooth in hue, chroma, value, maverick colors, and surface texture. Equally important is the visual harmony of the facial and proximal soft-tissue contours, which requires the collaborative skills of the restorative dentist, periodontist, and dental technician. The treatment team must understand the biologic structures adjacent to natural dentition and dental implants. This report describes the potential for specifically designed restorative contours to dictate the optimal gingival profile for tooth-supported and implant-supported crowns. Showing several cases, the article explains how esthetic soft-tissue contours enhance the definitive crown restoration, highlights the importance of clinical evaluation of adjacent biologic structures, and discusses keys to predicting when the proximal papilla has the potential to return to a favorable height and shape.
Molina, Ana; Sanz-Sánchez, Ignacio; Martín, Conchita; Blanco, Juan; Sanz, Mariano
2017-04-01
To compare the effect of placing the definitive abutment at the time of implant placement versus at a later stage, on the soft and hard tissue changes around dental implants. Platform-switched implants were placed in the posterior maxilla or mandible of partial edentulous patients and they were randomized to receive the definitive abutment at the moment of implant placement, or 6-12 weeks later. Final prostheses were delivered 2-4 weeks later. Radiographic assessment of vertical bone level changes (primary outcome), clinical status of peri-implant tissues, changes in soft tissues margin, papilla filling, patient-related outcomes and adverse events were assessed 6 and 12 months after loading. 60 implants were placed in 40 patients, replacing single or multiple absent teeth. One implant was lost 1 week after insertion (overall survival rate: 98.3%). A statistically significant greater bone resorption from surgery to 6 months post-loading was observed for those implants subjected to abutment change (control group: -1.24 ± 0.79 mm; test group: -0.61 ± 0.40 mm; P = 0.028). Periodontal clinical parameters and patient-related outcomes, however, did not demonstrate significant differences between groups at any time point. A significant increase in papilla height was observed from loading to 12 months in all implants (control group: 1.17 ± 1.47 mm; test group: 0.98 ± 0.89 mm) and a slight but not significant coronal migration of the gingival margin. The connection and disconnection of healing abutments is associated with significantly increased bone loss during the healing period between implant placement and 6 months post-loading, when compared to one-time abutment placement. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Urban, Istvan A; Monje, Alberto; Wang, Hom-Lay
2015-01-01
Severe vertical ridge deficiency in the anterior maxilla represents one of the most challenging clinical scenarios in the bone regeneration arena. As such, a combination of vertical bone augmentation using various biomaterials and soft tissue manipulation is needed to obtain successful outcomes. The present case series describes a novel approach to overcome vertical deficiencies in the anterior atrophied maxillae by using a mixture of autologous and anorganic bovine bone. Soft tissue manipulation including, but not limited to, free soft tissue graft was used to overcome the drawbacks of vertical bone augmentation (eg, loss of vestibular depth and keratinized mucosa). By combining soft and hard tissue grafts, optimum esthetic and long-term implant prosthesis stability can be achieved and sustained.
Esthetic soft tissue management for teeth and implants.
Fu, Jia-Hui; Su, Chuan-Yi; Wang, Hom-Lay
2012-09-01
Can newly introduced graft materials be successfully used in soft tissue augmentation around teeth and dental implants? An electronic search on the PubMed database for English articles published before March 31, 2012, was performed using the following key words: "root coverage," "soft tissue graft," "periodontal plastic surgery," "subepithelial connective graft (SCTG)," "acellular dermal matrix (ADM)," "guided tissue regeneration based root coverage (GTRC)," "recession defects," "mucogingival defects," "collagen matrix," "living cellular construct (LCC)," "mucograft," and "biologic agents." Literature featuring new soft tissue graft materials, such as ADM, collagen matrix, GTRC, and biologic agents, were included. Data showed (1) allogeneic grafts were comparable to SCTG in terms of mean complete root coverage (CRC), mean root coverage (RC), and mean amount of keratinized tissue (KT) gain; (2) xenogeneic collagen matrix was as comparable to SCTG in terms of mean amount of KT gain around teeth and dental implants but inferior in achieving RC; (3) GTRC was inferior to SCTG in terms of mean CRC and mean RC; (4) LCC was inferior to free gingival graft in terms of mean amount of KT gain but was superior in esthetics and patient satisfaction; and (5) adjunctive use of biologic agents did not exert a significant effect on mean CRC, mean RC, and mean amount of KT gain. Although these new materials do not surpass the gold standard (SCTG), they do provide improved patient satisfaction and esthetics, are available in abundance, and lead to reduced postoperative discomfort and surgical time. Copyright © 2012 Elsevier Inc. All rights reserved.
Aschoff, H H; Clausen, A; Hoffmeister, T
2009-01-01
The implantation of an intramedullary transcutaneously conducted femur prosthesis presents a rather new procedure for the rehabilitation of above-knee amputated patients. The aim of the so-called endo-exo prosthesis is to avoid the well-known problems at the interface between the sleeve of the prosthesis and the soft tissue coat of the femur stump which often impedes an inconspicuous and harmonic gait. The company ERSKA Implants in Lübeck/Germany has developed an intramedullary femur prosthesis with a spongiosa metal-configurated relief surface which, when implanted cementless, enables a secure osseointegration and allows a more direct transmission of muscle power to the lower leg prosthesis. A minimum length of 16-18 cm and a sufficient soft tissue coverage of the femur stump is needed. The problems at the perforation point of the implant through the soft tissue coat can be handled or even be avoided and they do not necessarily provoke an intramedullary infection. We report on 30 cases that were operated between 1999 and 2008. The design of the prosthesis, aspects of the operative procedure and latest results are presented.
Sainsbury, David C G; George, Alan; Forrest, Christopher R; Phillips, John H
2017-03-01
The authors performed bilateral malar reconstruction using polyether ether ketone implants in 3 patients with Treacher-Collins syndrome with absent, as opposed to hypoplastic, zygomata. These patient-specific implants were fabricated using computed-aided design software reformatted from three-dimensional bony preoperative computed tomography images. The first time the authors performed this procedure the implant compressed the globe resulting in temporary anisocoria that was quickly recognized intraoperatively. The implant was immediately removed and the patient made a full-recovery with no ocular disturbance. The computer-aided design and manufacturing process was adjusted to include periorbital soft-tissue boundaries to aid in contouring the new implants. The same patient, and 2 further patients, subsequently underwent malar reconstruction using this soft tissue periorbital boundary fabrication process with an additional 2 mm relief removed from the implant's orbital surface. These subsequent procedures were performed without complication and with pleasing aesthetic results. The authors describe their experience and the salutary lessons learnt.
Hemmrich, Karsten; von Heimburg, Dennis; Rendchen, Raoul; Di Bartolo, Chiara; Milella, Eva; Pallua, Norbert
2005-12-01
The reconstruction of soft tissue defects following extensive deep burns or tumor resections remains an unresolved problem in plastic and reconstructive surgery since adequate implant materials are still not available. Preadipocytes, immature precursor cells found between mature adipocytes in adipose tissue, are a potential material for soft tissue engineering since they can proliferate and differentiate into adipose tissue after transplantation. In previous studies, we identified hyaluronan benzyl ester (HYAFF 11) sponges to be promising carrier matrices. This study now evaluates, in vitro and in vivo, a new sponge architecture with pores of 400 microm either made of plain HYAFF 11 or HYAFF 11 coated with the extracellular matrix glycosaminoglycan hyaluronic acid. Human preadipocytes were isolated, seeded onto carriers and implanted into nude athymic mice. Explants harvested after 3, 8, and 12 weeks were examined for macroscopical appearance, thickness, weight, pore structure, histology, and immunohistochemistry. Compared to previous studies, we found better penetration of cells into both types of scaffolds, with more extensive formation of new vessels throughout the construct but with only minor adipose tissue. Our encouraging results contribute towards a better seeded and vascularised scaffold but also show that the enhancement of adipogenic conversion of preadipocytes remains a major task for further in vivo experiments.
Peri-implant and periodontal tissues: a review of differences and similarities.
Dhir, Sangeeta; Mahesh, Lanka; Kurtzman, Gregori M; Vandana, K L
2013-01-01
The health and vitality of an osseointegrated implant depends on the surrounding supporting tissues, which not only anchor the implant to the bone but also have the important function of providing a protective seal. The aim of this article is to provide a basic understanding of differences and similarities between the periodontal and peri-implant tissues at the histologic, clinical, and immunologic levels; it is essential to know these differences and similarities during the clinical handling of these similar-looking tissues. The comparative features are of clinical relevance because it is critical to understand the behavior of the soft tissue found around the tooth and implant. This knowledge is vital from the preliminary stage of treatment planning through prosthetic rehabilitation.
Pecnik, Christina M; Roos, Malgorzata; Muff, Daniel; Spolenak, Ralph; Sailer, Irena
2015-05-01
The aim of this study was to characterize the optical properties of newly developed esthetic coatings for metallic implants and components for an improved peri-implant soft tissue appearance. Pig maxillae (n = 6) were used for the in vitro color evaluation of coated and uncoated samples. Three different coating systems (Ti-ZrO(2), Ti-Al-ZrO(2), and Ti-Ag-ZrO(2)) were deposited on titanium substrates, which exhibited different roughness (polished, machined, and sand-blasted) and interference colors (pink, yellow, and white). Spectrophotometric measurements were made of samples below three different mucosa thicknesses (1 mm, 2 mm, and 3 mm) and titanium served as negative control. Color difference ΔE was calculated using ΔL, Δa, and Δb values for each sample (in total 30 samples). ΔE values were significantly above the threshold value of 3.70 for sand-blasted Ti and Ti-ZrO(2) samples when tested below 1 mm thick soft tissue, hence resulted in a dark appearance of the soft tissues. In contrast, Ti-Al-ZrO(2) and Ti-Ag-ZrO(2) samples showed significant ΔL values below 1 mm, which indicates a brightening of the covering tissue. In general, ΔE values decreased with increasing thickness of the tissue. At 3 mm thick tissue, ΔE values were significantly below 3.70 for Ti-Al-ZrO(2) and Ti-Ag-ZrO(2) samples. The preferable substrate surface should be machined due increased color brightness, good soft tissue integration and improved adhesion between coating and substrates. Improvement of the optical appearance of the metal was achieved with the coating systems Ti-Al-ZrO(2) and Ti-Ag-ZrO(2). Darkening effects could not be observed for these systems, and partially light brightening of the tissue was observed. Advantageous colors were suggested to be pink and yellow. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Kang, Norbert V; Pendegrass, Catherine; Marks, Linda; Blunn, Gordon
2010-07-01
Exoprosthetic replacement with an artificial limb is the main option for reconstruction after traumatic amputation of an upper limb. Direct skeletal attachment using an osseointegrated implant improves the ease of fixation of the exoprosthesis to the amputation stump. We now report the use of an intraosseous transcutaneous amputation prosthesis that is designed to achieve osseocutaneous integration. Osseocutaneous integration differs from osseointegration because the aim is to create a stable interface among the implant, the bone, and the soft tissues. This reduces the risk of soft tissue infection and troublesome discharge, which are problems encountered with current osseointegrated implants that focus largely on the bone-implant interface. We describe our experience with an intraosseous transcutaneous amputation prosthesis in a case of transhumeral amputation with 2 years of follow-up. Copyright 2010 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Finelle, Gary; Papadimitriou, Dimitrios E V; Souza, André B; Katebi, Negin; Gallucci, German O; Araújo, Mauricio G
2015-04-01
To assess (i) the outcome of changing the horizontal-offset dimension on the peri-implant soft tissues and the crestal bone and (ii) the effect of different healing abutments (flared vs. straight) on the marginal peri-implant soft tissues and crestal bone. Two-piece dental implants diameters of 3.5 and 4.5 mm were placed at least 1 mm subcrestal in five beagle dogs. Three different investigational groups: (i) 3.5-mm-diameter implant with narrow healing abutment (3.5N), (ii) 4.5-mm-diameter implant with narrow healing abutment (4.5N), and (iii) 3.5-mm-diameter implant with wide healing abutment (3.5W), were assessed. After 4 months of healing, the vertical distance from the marginal crestal bone (MB) to the implant shoulder (IS); the vertical distance from the IS to the first bone-to-implant contact; and the horizontal distance of bone ingrowth on the implant platform were measured with a high-resolution micro-CT (Xradia MicroXCT-200 system). Implants with a narrow healing caps showed an interproximal MB located between 0 and 1 mm above the implant shoulder, while the 3.5W group exhibits a mean value -0.50 mm. As all implants in group 3.5N presented a fBIC located at the level of the IS. For the 4.5N group, the mean fBIC-IS distance was -0.52 mm apically to the IS. For the 3.5WC group, the mean fBIC-IS distance was -1.42 mm. Horizontal bone apposition was only observed for the 3.5N group and the 4.5N group. The dimension of the horizontal offset would play a minimal role in reducing bone remodeling, whereas the configuration of the transmucosal component would directly influence marginal bone remodeling. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
El Chaar, Edgard; Oshman, Sarah; Cicero, Giuseppe; Castano, Alejandro; Dinoi, Cinzia; Soltani, Leila; Lee, Yoonjung Nicole
Localized ridge resorption, the consequence of socket collapse, following tooth extraction in the anterior maxilla can adversely affect esthetics, function, and future implant placement. Immediate grafting of extraction sockets may help preserve natural ridge contours, but a lack of available soft tissue can compromise the final esthetic outcome. The presented modified rotated palatal pedicle connective tissue flap is a useful technique for simultaneous soft tissue coverage and augmentation of grafted sockets to improve esthetic outcome. This article delineates its advantages through the presentation of a four-case series using this new technique.
Choi, Changsoon; Choi, Moon Kee; Liu, Siyi; Kim, Min Sung; Park, Ok Kyu; Im, Changkyun; Kim, Jaemin; Qin, Xiaoliang; Lee, Gil Ju; Cho, Kyoung Won; Kim, Myungbin; Joh, Eehyung; Lee, Jongha; Son, Donghee; Kwon, Seung-Hae; Jeon, Noo Li; Song, Young Min; Lu, Nanshu; Kim, Dae-Hyeong
2017-11-21
Soft bioelectronic devices provide new opportunities for next-generation implantable devices owing to their soft mechanical nature that leads to minimal tissue damages and immune responses. However, a soft form of the implantable optoelectronic device for optical sensing and retinal stimulation has not been developed yet because of the bulkiness and rigidity of conventional imaging modules and their composing materials. Here, we describe a high-density and hemispherically curved image sensor array that leverages the atomically thin MoS 2 -graphene heterostructure and strain-releasing device designs. The hemispherically curved image sensor array exhibits infrared blindness and successfully acquires pixelated optical signals. We corroborate the validity of the proposed soft materials and ultrathin device designs through theoretical modeling and finite element analysis. Then, we propose the ultrathin hemispherically curved image sensor array as a promising imaging element in the soft retinal implant. The CurvIS array is applied as a human eye-inspired soft implantable optoelectronic device that can detect optical signals and apply programmed electrical stimulation to optic nerves with minimum mechanical side effects to the retina.
Boyce, R G; Toriumi, D M
1992-01-01
Surgical changes in the contour of soft tissue and bone of the craniomaxillofacial structures may require use of a biologic graft or alloplastic implant. Autologous materials are preferred; however, the harvesting procedure, donor site, and its associated morbidity are the disadvantages of using autografts. There are numerous types of alloplastic implants and they all differ in how they interact with host tissues. Factors such as implant texture, ability to integrate with host tissues, and rate of resorption all influence the overall success of different implants. In this article, we discuss some considerations in the use of biologic grafts and alloplastic implants in facial plastic and reconstructive surgery.
Cabello, Gustavo; Rioboo, María; Fábrega, Javier G
2013-10-01
The aim of this prospective study was to evaluate the soft tissue changes around implants in the aesthetic zone, placed under a trimodal approach (immediate post-extraction placement, flapless, and immediate provisional restoration) and its relationship to gingival/periodontal biotype of the patient. The sample consisted of 14 patients from two private practices that were in need of a tooth extraction in the anterior maxillary region (cuspid to cuspid) and were candidates to a replacement with a dental implant. An initial measurement (baseline) of the position or the mesial and distal papillae and gingival zenith was made at this time, with a rigid dental-supported stent and an electronic precision caliper, able to the second tenth of a millimeter; after careful tooth extraction, the periodontal thickness, at a point 5 mm apical to de gingival buccal margin, with an analogical thickness gauge, able to one tenth of a millimeter. Once the implant was inserted an immediate provisional restoration was delivered. To evaluate the soft tissue changes measurements were repeated at 3, 6, and 12 months. A statistical analysis was performed to evaluate the changes in the gingival margin around the implant restorations and to identify a possible correlation to patient's periodontal thickness. All 14 patients received Straumann (®) implants (9 Tissue Level [TL] Regular Neck [RN], 2 TL Narrow Neck [NN], 2 Bone Level [BL] Narrow Crossfit [NC], and 1 BL Regular Crossfit [RC]). All implants integrated and none had any biological complications. Three provisional restorations presented screw loosening and retightened once and one loss retention and was recemented once. In one patient, with a severe bruxing habit, the final restoration suffered screw loosening and was retightened. Of the final restorations, 12 were screw-retained and 2 cemented on custom-made Zirconia abutments. A mean recession of the buccal margin of 0.45 mm was recorded at 12 months ( ± 0.25 mm). An acceptable papilla level was present in all cases at 1 year, with mean changes of 0.38 mm ( ± 0.60) for the mesial and 0.80 mm ( ± 0.90) of the distal papilla, respectively. No correlation could be established between the soft tissue changes and the periodontal biotype of the patient. Within the limitations of this study, the good aesthetic outcome and minimal complications seem to validate the trimodal approach protocol as a reliable and simple protocol to place and restore immediate implants in the aesthetic zone. No correlation between the patient's gingival biotype and the soft tissue alterations could be established. Additional studies are needed to verify long-term aesthetic results with this approach and to better define and quantify biotypes. © 2012 John Wiley & Sons A/S.
Bienz, Stefan P; Jung, Ronald E; Sapata, Vitor M; Hämmerle, Christoph H F; Hüsler, Jürg; Thoma, Daniel S
2017-11-01
To evaluate the volumetric changes and peri-implant health at implant sites with and without previous soft tissue grafting over a 5-year observation period. In 18 partially edentulous patients, dental implants were placed in the esthetic zone (15-25) with simultaneous guided bone regeneration, followed by submerged healing. During the healing phase, eight patients (test) received a subepithelial connective tissue graft, whereas 10 patients (control) did not receive any soft tissue augmentation. Subsequently, abutment connection was performed and final reconstructions were inserted. Impressions were taken 1 week after crown insertion and at 5 years. Obtained casts were scanned and superimposed for volumetric and linear measurements. The mean distance (MD) in the mid-buccal area between the two surfaces and the differences in buccal marginal mucosal level (bMML change ) and in ridge width (RW change ) were evaluated. Peri-implant health was assessed using probing pocket depth (PPD) values, plaque index (PlI) and bleeding on probing (BOP). At a median follow-up time of 60.5 months a median MD of -0.38 mm (Min: -0.94; Max: -0.03) (test) and of -0.51 mm (Min: -0.76; Max: 0.05) (control) was calculated. The level of the margo mucosae (bMML change ) demonstrated a median loss of -0.42 mm (Min: -1.1; Max: -0.01) (test) and of -0.33 mm (Min: -1.02; Max: 0.00) (control). The median RW change ranged between -0.44 mm and -0.73 mm (test) and between -0.49 mm and -0.54 mm (control). Mean PPD values slightly increased, whereas PlI and BOP remained stable over time in both groups. None of the comparisons between the groups revealed statistically significant differences (P > 0.35). A small sample size must be considered, however. Limited by a retrospective case-control study design, implant sites with and without soft tissue grafting on the buccal side revealed only minimal volumetric and linear changes and stability of peri-implant parameters over 5 years. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Schwarz, Frank; Derks, Jan; Monje, Alberto; Wang, Hom-Lay
2018-06-01
This narrative review provides an evidence-based overview on peri-implantitis for the 2017 World Workshop on the Classification of Periodontal and Peri-Implant Diseases and Conditions. A literature review was conducted addressing the following topics: 1) definition of peri-implantitis; 2) conversion from peri-implant mucositis to peri-implantitis, 3) onset and pattern of disease progression, 4) characteristics of peri-implantitis, 5) risk factors/indicators for peri-implantitis, and 6) progressive crestal bone loss in the absence of soft tissue inflammation. 1)Peri-implantitis is a pathological condition occurring in tissues around dental implants, characterized by inflammation in the peri-implant connective tissue and progressive loss of supporting bone. 2)The histopathologic and clinical conditions leading to the conversion from peri-implant mucositis to peri-implantitis are not completely understood. 3)The onset of peri-implantitis may occur early during follow-up and the disease progresses in a non-linear and accelerating pattern. 4a)Peri-implantitis sites exhibit clinical signs of inflammation and increased probing depths compared to baseline measurements. 4b)At the histologic level, compared to periodontitis sites, peri-implantitis sites often have larger inflammatory lesions. 4c)Surgical entry at peri-implantitis sites often reveals a circumferential pattern of bone loss. 5a)There is strong evidence that there is an increased risk of developing peri-implantitis in patients who have a history of chronic periodontitis, poor plaque control skills, and no regular maintenance care after implant therapy. Data identifying "smoking" and "diabetes" as potential risk factors/indicators for peri-implantitis are inconclusive. 5b)There is some limited evidence linking peri-implantitis to other factors such as: post-restorative presence of submucosal cement, lack of peri-implant keratinized mucosa and positioning of implants that make it difficult to perform oral hygiene and maintenance. 6)Evidence suggests that progressive crestal bone loss around implants in the absence of clinical signs of soft tissue inflammation is a rare event. © 2018 American Academy of Periodontology and European Federation of Periodontology.
Hing, James T; Brooks, Ari D; Desai, Jaydev P
2007-02-01
A methodology for modeling the needle and soft-tissue interaction during needle insertion is presented. The approach consists of the measurement of needle and tissue motion using a dual C-arm fluoroscopy system. Our dual C-arm fluoroscopy setup allows real time 3-D extraction of the displacement of implanted fiducials in the soft tissue during needle insertion to obtain the necessary parameters for accurate modeling of needle and soft-tissue interactions. The needle and implanted markers in the tissue are tracked during the insertion and withdrawal of the needle at speeds of 1.016 mm/s, 12.7 mm/s and 25.4 mm/s. Both image and force data are utilized to determine important parameters such as the approximate cutting force, puncture force, the local effective modulus (LEM) during puncture, and the relaxation of tissue. We have also validated the LEM computed from our finite element model with arbitrary needle puncture tasks. Based on these measurements, we developed a model for needle insertion and withdrawal that can be used to generate a 1-DOF force versus position profile that can be experienced by a user operating a haptic device. This profile was implemented on a 7-DOf haptic device designed in our laboratory.
Surface Modification of Dental Titanium Implant by Layer-by-Layer Electrostatic Self-Assembly
Shi, Quan; Qian, Zhiyong; Liu, Donghua; Liu, Hongchen
2017-01-01
In vivo implants that are composed of titanium and titanium alloys as raw materials are widely used in the fields of biology and medicine. In the field of dental medicine, titanium is considered to be an ideal dental implant material. Good osseointegration and soft tissue closure are the foundation for the success of dental implants. Therefore, the enhancement of the osseointegration and antibacterial abilities of titanium and its alloys has been the focus of much research. With its many advantages, layer-by-layer (LbL) assembly is a self-assembly technique that is used to develop multilayer films based on complementary interactions between differently charged polyelectrolytes. The LbL approach provides new methods and applications for the surface modification of dental titanium implant. In this review, the application of the LbL technique to surface modification of titanium including promoting osteogenesis and osseointegration, promoting the formation and healing of soft tissues, improving the antibacterial properties of titanium implant, achieving local drug delivery and sustained release is summarized. PMID:28824462
Mankoo, Tidu
2007-01-01
In recent years, implant dentistry has undergone a profound shift in emphasis. The focus evolved first from a surgically driven approach to a prosthetically driven approach and now to a more biologically driven approach with the goal of optimizing and maintaining esthetics. While traditional implant protocols are well established for management of implants placed in healed edentulous sites, the data available offer little clarity on the factors and procedures for long-term esthetic success, particularly in terms of maintained stable soft tissue outcomes around implant restorations in the esthetic zone. Unfortunately, the 90%+ success rates indicated in most studies of dental implant systems today do not represent the success of the esthetic outcome. This has created a demand--certainly among clinicians in private practice focused on the ongoing maintenance of esthetic outcomes--for clear treatment protocols to achieve esthetic results that are not only predictable and consistent but that can withstand the test of time.
Wobker, Sara E; Aron, Manju; Epstein, Jonathan I
2016-11-01
In the upper genitourinary tract of the ureter and renal pelvis, any invasion of urothelial carcinoma (UC) beyond the thin muscularis is considered pT3 disease, which may prompt adjuvant chemotherapy. Ureteroscopy is commonly used in the workup of these lesions to obtain tissue biopsies and cytology specimens, or to place stents for the relief of obstructive symptoms. The current study describes 4 cases in which the presence of small nests of urothelium in periureteral and peripelvic soft tissue was noted after ureteroscopic instrumentation, mimicking high-stage UC. All 4 cases had a history of ureteral instrumentation with biopsy of the suspected UC. The diagnostic biopsies showed low-grade noninvasive papillary UC (n=2), papillary urothelial neoplasm of uncertain malignant potential (n=1), and benign inverted urothelial papilloma (n=1). In the definitive resection specimens, small nests of bland urothelium were present in the periureteral or peripelvic soft tissue, raising the possibility of pT3 UC. We interpreted these displaced small nests to be the result of mechanical implantation occurring during the ureteroscopic procedure on the basis of the finding of associated linear fibrosis, inflammation, hemorrhage, and foreign body giant cells. In the setting of low-grade or benign urothelial neoplasms in the upper urinary tract, caution is warranted when cytologically bland nests of the urothelium are identified beyond the muscularis that could represent mechanically induced implants as opposed to invasive UC extending into peripelvic or periureteral soft tissue.
Extraction socket sealing using palatal gingival grafts and resorbable collagen membranes.
Kim, Sang-Yun; Kim, Young-Kyun; Kim, Hyun-Suk; Yun, Pil-Young; Kim, Su-Gwan; Choi, Yong-Hun
2017-12-01
Socket sealing surgery is performed for the preservation of the form and volume of the soft tissue by covering the resulting socket with autogenous soft tissue graft or membrane barriers. This procedure is usually necessary to improve the esthetic results of the maxillary anterior or premolar areas. This study retrospectively investigated cases involving the open membrane technique or socket sealing surgery with a palatal gingival graft or collagen membrane where implant placement and bone grafting were performed immediately after tooth extraction. From January 2005 to December 2008, socket sealing surgery was performed in 24 patients, and 25 implants were placed. All implants were successful in the follow-up period. In the palatal gingival graft group, the mean marginal bone loss was 1.17 mm during the mean follow-up period of 81.0 months. In the collagen membrane group, the mean marginal bone loss was 1.23 mm during the mean follow-up period of 76.9 months. There was no significant difference between the two groups. Consequently, socket sealing surgery is effective at minimizing the loss of soft tissue and alveolar bone.
Morice, Anne; Kolb, Frédéric; Picard, Arnaud; Kadlub, Natacha; Puget, Stéphanie
2017-01-01
Reconstruction of complex skull defects requires collaboration between neurosurgeons and plastic surgeons to choose the most appropriate procedure, especially in growing children. The authors describe herein the reconstruction of an extensive traumatic bone and soft tissue defect of the cranial vault in an 11-year-old boy. The size of the defect, quality of the tissues, and patient's initial condition required a 2-stage approach. Ten months after an initial emergency procedure in which lacerated bone and soft tissue were excised, reconstruction was performed. The bone defect, situated on the left frontoparietal region, was 85 cm 2 and was filled by a custom-made porous hydroxyapatite implant. The quality of the overlying soft tissue did not allow the use of classic local and locoregional coverage techniques. A free latissimus dorsi muscle flap branched on the contralateral superficial temporal pedicle was used and left for secondary healing to take advantage of scar retraction and to minimize alopecia. Stable well-vascularized implant coverage as well as an esthetically pleasing skull shape was achieved. Results in this case suggest that concomitant reconstruction of large calvarial defects by cranioplasty with a custom-made hydroxyapatite implant covered by a free latissimus dorsi muscle flap is a safe and efficient procedure in children, provided that there is no underlying infection of the operative site.
Watzak, Georg; Zechner, Werner; Tangl, Stefan; Vasak, Christoph; Donath, Karl; Watzek, Georg
2006-04-01
The purpose of this study was to determine the peri-implant soft tissue dimension (PSD) and peri-implant bone level (BL) of dental implants with different designs and surface modifications after functional loading without oral hygiene. Three types of dental implants were placed in the posterior jaws of adult baboons, three of the same design per quadrant, and fitted with fixed partial dentures. After 1.5 years of functional loading and plaque accumulation, all implants showed severe peri-implant mucositis and comparatively high BL. A histomorphometric evaluation of the sulcus depth (SD), the dimension of the junctional epithelium (JE) and the connective tissue contact (CTC) resulted in no significant differences between the three implant designs, neither in the maxilla nor in the mandible (P>0.05). The sum of SD, JE and CTC forming the PSD was nearly the same in the maxilla (commercially pure titanium, CpTi: 3.5 mm 2.9/4.1 confidence interval (CI); titanium plasma sprayed (TPS): 3.5 mm 2.9/4.2 CI; sand blasted acid-etched (GBAE): 3.2 mm 2.7/3.9 CI) and in the mandible (CpTi: 3.2 mm 2.6/3.8 CI; TPS: 3.2 mm 2.6/3.8 CI; GBAE: 3.2 mm 2.7/3.9 CI; P>0.05). There was no difference in BL around the three implant designs (maxilla: CpTi: 0.9 mm 0.5/1.6 CI; TPS: 0.9 mm 0.5/1.5CI; GBAE: 0.9 mm 0.5/1.6 CI; mandible: CpTi: 0.8 mm 0.5/1.2 CI; TPS: 0.6 mm 0.4/0.9 CI; GBAE: 0.7 mm 0.5/1.1 CI; P>0.05). Overall, the data presented did not show any significant differences in peri-implant soft tissue conditions in baboons. Moreover, plaque accumulation and propagation of peri-implant mucositis after 1.5 years of functional loading was not influenced by implant design and surface modifications in baboons.
Barone, Antonio; Alfonsi, Fortunato; Derchi, Giacomo; Tonelli, Paolo; Toti, Paolo; Marchionni, Saverio; Covani, Ugo
2016-06-01
The insertion torque value has been extensively used as an indicator for implant primary stability, which is considered a determining parameter for the implants success. The primary goal of the present randomized clinical trial was to evaluate and compare the clinical outcome for implants placed with high insertion torque (between 50 Ncm and 100 Ncm) and regular insertion torque (within 50 Ncm) in healed ridges. Partially edentulous patients, missing one or more mandibular or maxillary teeth, having an adequate amount of bone, requiring implant placement, were randomized to receive Blossom CT implants with regular insertion torque (<50 Ncm) or CT implants with high insertion torque (≥50 Ncm). Implants were left to heal submerged for 3 months. Implants were restored with individualized abutments and cemented metal-ceramic crowns. Acquired measurements were: insertion torque values (IT), thickness of buccal bone plate after implant osteotomy preparation (BBT), marginal bone level (MBL), and facial soft tissue level (FST). All patients were followed 12 months after implant placement. One hundred sixteen implants were placed in one hundred sixteen patients and enrolled for the study. Fifty-eight implants were randomly allocated in regular-IT and high-IT groups with a mean insertion torque ranging from 20 Ncm to 50 Ncm and from 50 Ncm to 100 Ncm, respectively. Three implants failed, and another five implants showed at the 12-month evaluation a marginal bone loss (ΔMBL) greater than 1.5 mm, being considered unsuccessful. The findings suggested that implants inserted with high-IT (≥50 Ncm) in healed bone ridges showed more peri-implant bone remodeling and buccal soft tissue recession than implants inserted with a regular-IT (<50 Ncm). Moreover, sites with a thick buccal bone wall (≥1 mm) - after implant osteotomy site preparation - seemed to be less prone to buccal soft tissue recession after 12 months than sites with a thin buccal bone wall (<1 mm). © 2015 Wiley Periodicals, Inc.
Kharade, Pankaj; Banerjee, Ardhendu; Gupta, Tapas
2012-01-01
A diagnostic radiograph of the posterior regions of the jaws is mandatory if implant placement is considered at these sites. The goal is to avoid damage to important anatomical structures such as the inferior alveolar canal and maxillary sinus. Using radiographs to evaluate the remaining bone height available for implant insertion is a common procedure. Many articles have evaluated the success rates of fixed prostheses supported by osseointegrated implants, indicating high rates of success for prostheses 5-10 years in function. However, if an orthopantomogram machine is not readily available, periapical radiographs can be used for vertical bone height assessment. The familiar procedure of incorporating a metal ball of known diameter into an acrylic template is the method of choice. This is a relatively tedious and expensive procedure involving multiple steps, including impression taking, creation of a study model, and manufacture of a metal ball-bearing acrylic template. A further disadvantage for the patient is that a diagnostic radiograph can be taken only at the next appointment. This paper describes a quick and simple method to obtain a radiographic evaluation of remaining alveolar bone height and soft tissue thickness prior to implant placement with help of a metal ball device to avoid template fabrication and time consumption. Soft tissue thickness is measured nonsurgically.
Calvarial reconstruction using high-density porous polyethylene cranial hemispheres
Mokal, Nitin J.; Desai, Mahinoor F.
2011-01-01
Aims: Cranial vault reconstruction can be performed with a variety of autologous or alloplastic materials. We describe our experience using high-density porous polyethylene (HDPE) cranial hemisphere for cosmetic and functional restoration of skull defects. The porous nature of the implant allows soft tissue ingrowth, which decreases the incidence of infection. Hence, it can be used in proximity to paranasal sinuses and where previous alloplastic cranioplasties have failed due to implant infection. Materials and Methods: We used the HDPE implant in seven patients over a three-year period for reconstruction of moderate to large cranial defects. Two patients had composite defects, which required additional soft tissue in the form of free flap and tissue expansion. Results: In our series, decompressive craniectomy following trauma was the commonest aetiology and all defects were located in the fronto-parieto-temporal region. The defect size was 10 cm on average in the largest diameter. All patients had good post-operative cranial contour and we encountered no infections, implant exposure or implant migration. Conclusions: Our results indicate that the biocompatibility and flexibility of the HDPE cranial hemisphere implant make it an excellent alternative to existing methods of calvarial reconstruction. PMID:22279274
Oxby, Gert; Oxby, Fredrik; Oxby, Johan; Saltvik, Tomas; Nilsson, Peter
2015-10-01
Immediate placement of implants in extraction sockets for early loading is an attractive treatment modality due to reduced treatment time. However, the outcome of fluoridated implants in this situation with regard to bone levels and health of soft tissues is not well documented. To evaluate the outcome of early loading of OsseoSpeed(™) dental implants placed into fresh extraction sockets and healed bone in consecutive patients treated in a private clinic. A total of 182 OsseoSpeed(™) implants (Astra Tech Implant System, DENTSPLY Implants, Mölndal, Sweden), 72 in immediate extraction sockets and 110 in healed sites, were placed in 39 consecutive patients. The implants were loaded with permanent restorations within 60 days (average 31 days). Clinical and radiographic follow-up examinations were performed annually for at least 3 years (mean 55 months). An aesthetic index was used to evaluate the soft tissues adjacent to the prosthetic restorations. No implant was lost during the observation period, giving a survival rate of 100%. Bone level changes during the observation period were minimal, with a mean marginal bone loss of 0.3 ± 0.9 mm around the delayed implants and a mean marginal bone gain of 0.3 ± 1.4 mm around the immediate implants (p = .0036). The frequency distribution of bone level revealed that 85% of implants placed in fresh extraction sockets and 84% of implants in healed bone did not show any loss of bone level during follow-up (p = NS). Soft tissue complications were observed at two immediate implant sites in one patient. The remaining 180 implants received the highest aesthetic score. Moreover, no signs of peri-implant purulent infection or aggressive bone loss were found during the follow-up period. Early loading of fluoridated implants with permanent constructions appears to be a viable therapy for implants placed immediately in extraction sites and in healed bone. © 2014 Wiley Periodicals, Inc.
Swan, Marc C; Bucknall, David G; Czernuszka, Jan T; Pigott, David W; Goodacre, Timothy E E
2012-01-01
The advent of self-inflating hydrogel tissue expanders heralded a significant advance in the reconstructive potential of this technique. Their use, however, is limited by their uncontrolled isotropic (i.e., uniform in all directions) expansion. Anisotropy (i.e., directional dependence) was achieved by annealing a hydrogel copolymer of poly(methyl methacrylate-co-vinyl pyrrolidone) under a compressive load for a specified time period. The expansion ratio is dictated by the percentage of vinyl pyrrolidone content and the degree of compression. The expansion rate is modified by incorporating the polymer within a silicone membrane. The in vivo efficacy of differing prototype devices was investigated in juvenile pigs under United Kingdom Home Office Licence. The devices were implanted within a submucoperiosteal pocket in a total of six porcine palates; all were euthanized by 6 weeks after implantation. A longitudinal volumetric assessment of the expanded tissue was conducted, in addition to postmortem analysis of the bony and mucoperiosteal palatal elements. Uncoated devices caused excessive soft-tissue expansion that resulted in mucoperiosteal ulceration, thus necessitating animal euthanasia. The silicone-coated devices produced controlled soft-tissue expansion over the 6-week study period. There was a statistically significant increase in the volume of expanded soft tissue with no evidence of a significant acute inflammatory response to the implant, although peri-implant capsule formation was observed. Attenuation of the bony palatal shelf was noted. A unique anisotropic hydrogel device capable of controlled expansion has been developed that addresses a number of the shortcomings of the technology hitherto available.
[Diagnosis and therapy of particle disease in total hip arthroplasty].
Müller, M; Wassilew, G; Perka, C
2015-04-01
Particle disease is caused by periarticular accumulation of attrition particles and the inflammatory reaction of the body's tissue. This process may result in osteolysis or soft tissue transformation which presents itself symptomless in the beginning and can proceed to aseptic implant loosening, fracture, implant breaking as a result of the inappropriate osseous support and to algetic and destructive soft tissue reactions as well. Attrition particles originate from tribological pairing, and the extent of the attrition or the particle concentration depend on different factors as there are the tribological pairing's material, the head size, the patient's level of activity, and the implant position. Attrition particles can also be found in the range of any modular connection. Particle disease and its resulting morphological alterations of the tribological pairing is one of the most frequent reasons for re-operation in hip endoprosthetics. Georg Thieme Verlag KG Stuttgart · New York.
Absorbable Gels for Modulated Bioavailability of Vaccines. Phase I
1996-11-01
most of these devices were designed for repairing soft tissues , interest in using such transient devices, with or without biologically active components...potential applications of the in-situ-forming implants, and the more recent gel-formers, have been described to entail their use for tissue regeneration and...In Situ-Forming Biodegradable Polymeric Implants for Tissue Regeneration . Polym. Prepr., 35(2), 437 (1994). Edelman, R. et al, Immunization of
Abutment Material Effect on Peri-implant Soft Tissue Color and Perceived Esthetics.
Kim, Aram; Campbell, Stephen D; Viana, Marlos A G; Knoernschild, Kent L
2016-12-01
The purpose of this study was to evaluate the effect of implant abutment material on peri-implant soft tissue color using intraoral spectrophotometric analysis and to compare the clinical outcomes with patient and clinician perception and satisfaction. Thirty patients and four prosthodontic faculty members participated. Abutments were zirconia, gold-hued titanium, and titanium. Peri-implant mucosa color of a single anterior implant restoration was compared to the patient's control tooth. Spectrophotometric analysis using SpectroShade TM Micro data determined the color difference (ΔE, ΔL*, Δa*, Δb*) between the midfacial peri-implant soft tissue for each abutment material and the marginal gingiva of the control tooth. Color difference values of the abutment groups were compared using ANOVA (α = 0.05). Patient and clinician satisfaction surveys were also conducted using a color-correcting light source. The results of each patient and clinician survey question were compared using chi-square analysis (α = 0.05). Pearson correlation analyses identified the relationship between the total color difference (ΔE) and the patient/clinician perception and satisfaction, as well as between ΔE and tissue thickness. Zirconia abutments displayed significantly smaller spectrophotometric gingival color difference (ΔE) compared to titanium and gold-hued titanium abutments (respectively, 3.98 ± 0.99; 7.22 ± 3.31; 5.65 ± 2.11; p < 0.05). Among ΔL*, Δa*, and Δb*, only Δa* (red-green spectrum) showed significant difference between groups. There was no significant correlation between measured soft tissue thickness and ΔE, but thick gingival phenotype, determined by a probe test, demonstrated a smaller ΔE than thin phenotype (4.82 ± 1.49; 6.41 ± 3.27; p = 0.097). There was no statistical difference in patient or clinician satisfaction among abutment materials, and no correlation between ΔE and the patient and clinician satisfaction. Patient satisfaction was significantly higher than clinician, and patient-perceived differences were lower than clinicians' (p < 0.01). Clinicians' satisfaction was higher for gingival (pink) esthetics than crown (white) esthetics (p < 0.05). Peri-implant mucosa with zirconia abutments demonstrated significantly lower mean color difference compared to titanium or gold-hued titanium abutments as measured spectrophotometrically; however, no statistical difference in patient or clinician perception/satisfaction among abutment materials was demonstrated. Patients were significantly more satisfied than clinicians. © 2015 by the American College of Prosthodontists.
Rajgopal, Ashok; Dahiya, Vivek; Vasdev, Attique; Kochhar, Hemanshu; Tyagi, Vipin
2011-04-01
To report long-term results of total knee arthroplasty (TKA) for valgus knees. 34 women and 19 men aged 39 to 84 (mean, 74) years with valgus knees underwent primary TKA by a senior surgeon. Of the 78 knees, 43, 29, and 6 had type-I, type-II, and type-III valgus deformities, respectively. A preliminary lateral soft-tissue release was performed, and the tibia and femur were prepared. The tight lateral structures were released using the pie-crusting technique. In 92% of the knees, cruciate-retaining implants were used. In knees with severe deformity and medial collateral ligament insufficiency, the posterior cruciate ligament was sacrificed and constrained implants were used. The Hospital for Special Surgery (HSS) knee score was assessed, as were tibiofemoral alignment, range of motion, stability, and evidence of loosening or osteolysis. Patients were followed up for 8 to 14 (mean, 10) years. All knees had a good patellar position and were clinically stable in both mediolateral and anteroposterior planes. No radiolucency was noted. The mean HSS knee score improved from 48 to 91 (p<0.001). The mean tibiofemoral alignment improved from valgus 20 to 5 degrees (p<0.001). The mean range of motion improved from 65 to 110 degrees (p<0.001). One patient developed a deep infection at year 4, and 2 had periprosthetic fractures at years 6 and 8. Adequate lateral soft-tissue release is the key to successful TKAs in valgus knees. The choice of implant depends on the severity of the valgus deformity and the extent of soft-tissue release needed to obtain a stable, balanced flexion and extension gap, in order to achieve minimal constraint with maximum stability.
Utilization of robotic-arm assisted total knee arthroplasty for soft tissue protection.
Sultan, Assem A; Piuzzi, Nicolas; Khlopas, Anton; Chughtai, Morad; Sodhi, Nipun; Mont, Michael A
2017-12-01
Despite the well-established success of total knee arthroplasty (TKA), iatrogenic ligamentous and soft tissue injuries are infrequent, but potential complications that can have devastating impact on clinical outcomes. These injuries are often related to technical errors and excessive soft tissue manipulation, particularly during bony resections. Recently, robotic-arm assisted TKA was introduced and demonstrated promising results with potential technical advantages over manual surgery in implant positioning and mechanical accuracy. Furthermore, soft tissue protection is an additional potential advantage offered by these systems that can reduce inadvertent human technical errors encountered during standard manual resections. Therefore, due to the relative paucity of literature, we attempted to answer the following questions: 1) does robotic-arm assisted TKA offer a technical advantage that allows enhanced soft tissue protection? 2) What is the available evidence about soft tissue protection? Recently introduced models of robotic-arm assisted TKA systems with advanced technology showed promising clinical outcomes and soft tissue protection in the short- and mid-term follow-up with results comparable or superior to manual TKA. In this review, we attempted to explore this dimension of robotics in TKA and investigate the soft tissue related complications currently reported in the literature.
Containment-enhanced Ho:YAG photofragmentation of soft tissues
NASA Astrophysics Data System (ADS)
Christens-Barry, William A.; Guarnieri, Michael; Carson, Benjamin S.
1998-01-01
Laser surgery of soft tissue can exploit the power of brief, intense pulses of light to cause localized disruption of tissue with minimal effect upon surrounding tissue. In particular, studies of Ho:YAG laser surgery have shown that the effects of cavitation upon tissues and bone depend upon the physical composition of structures in the vicinity of the surgical site. For photofragmentation of occluding structures within catheters and other implant devices, it is possible to exploit the particular geometry of the catheter to amplify the effects of photofragmentation beyond those seen in bulk tissue. A Ho:YAG laser was used to photofragment occlusive material (tissue and tissue analogs) contained in glass capillary tubing and catheter tubing of the kind used in ventricular shunt implants for the management of hydrocephalus. Occluded catheters obtained from patient explants were also employed. Selection of operational parameters used in photoablation and photofragmentation of soft tissue must consider the physical composition and geometry of the treatment site. In the present case, containment of the soft tissue within relatively inelastic catheters dramatically alters the extent of photofragmentation relative to bulk (unconstrained) material. Our results indicate that the disruptive effect of cavitation bubbles is increased in catheters, due to the rapid displacement of material by cavitation bubbles comparable in size to the inner diameter of the catheter. The cylindrical geometry of the catheter lumen may additionally influence the propagation of acoustic shock waves that result from the collapse of the condensing cavitation bubbles.
Maiorana, C; Speroni, S; Herford, A S; Cicciù, M
2012-01-01
Approaching bone defects of jaws treatments, hard and soft tissue augmentation could be considered as a goal for clinicians when performing dental implant placement. The increase in patients who want cosmetic treatment puts practitioners in an awkward position when choosing the best therapy to obtain the most desirable results. A private dentist referred a young patient to the Department of Implantology in Milan in order to place implants in the upper jaw. Radiographic evaluation of the two upper anterior incisors confirmed that the teeth had a poor prognosis The anterior ridge volume was clinically analyzed and several therapeutic choices were evaluated. Rapid extractions and immediate implant positioning were not considered due to the vertical and horizontal components of the bone defect. Therefore, the surgical team decided on increasing the bone volume by using slow orthodontic teeth extrusion technique. After 3 months of orthodontic treatment, the angular intra-bony defects of 1.1 tooth was completely healed. Implant guided positioning, associated with a small bone graft, showed optimal results at the time of healing screw placement. The soft tissue conditioning was obtained by a provisional acrylic crown. The final application of two integral ceramic crowns showed excellent aesthetic results. Radiographic investigation at a 24 month follow-up confirmed the integration of the dental implants and the recovery of the bone defects. Several safe surgical techniques are available today for reconstructing atrophic jaws. However, the same technique applied on the posterior area did not give the same predictable results as in the anterior areas of the jaw. PMID:23056158
Histatin 1 Enhances Cell Adhesion to Titanium in an Implant Integration Model.
van Dijk, I A; Beker, A F; Jellema, W; Nazmi, K; Wu, G; Wismeijer, D; Krawczyk, P M; Bolscher, J G M; Veerman, E C I; Stap, J
2017-04-01
Cellular adhesion is essential for successful integration of dental implants. Rapid soft tissue integration is important to create a seal around the implant and prevent infections, which commonly cause implant failure and can result in bone loss. In addition, soft tissue management is important to obtain good dental aesthetics. We previously demonstrated that the salivary peptide histatin 1 (Hst1) causes a more than 2-fold increase in the ability of human adherent cells to attach and spread on a glass surface. Cells treated with Hst1 attached more rapidly and firmly to the substrate and to each other. In the current study, we examine the potential application of Hst1 for promotion of dental implant integration. Our results show that Hst1 enhances the attachment and spreading of soft tissue cell types (oral epithelial cells and fibroblasts) to titanium (Ti) and hydroxyapatite (HAP), biomaterials that have found wide applications as implant material in dentistry and orthopedics. For improved visualization of cell adhesion to Ti, we developed a novel technique that uses sputtering to deposit a thin, transparent layer of Ti onto glass slides. This approach allows detailed, high-resolution analysis of cell adherence to Ti in real time. Furthermore, our results suggest that Hst1 has no negative effects on cell survival. Given its natural occurrence in the oral cavity, Hst1 could be an attractive agent for clinical application. Importantly, even though Hst1 is specific for saliva of humans and higher primates, it stimulated the attachment and spreading of canine cells, paving the way for preclinical studies in canine models.
Demurashvili, Georgy; Davarpanah, Keyvan; Szmukler-Moncler, Serge; Davarpanah, Mithridade; Raux, Didier; Capelle-Ouadah, Nedjoua; Rajzbaum, Philippe
2015-10-01
Treating the edentulous patient with a gingival smile requires securing the prosthesis/soft tissue junction (PSTJ) under the upper lip. To present a simple method that helps achieve a predictable aesthetic result when alveoplasty of the anterior maxilla is needed to place implants apical to the presurgical position of the alveolar ridge. The maximum smile line of the patient is recorded and carved on a thin silicone bite impression as a soft tissue landmark. During the three-dimensional radiographic examination, the patient wears the silicone guide loaded with radiopaque markers. The NobelClinician® software is then used to bring the hard and soft tissue landmarks together in a single reading. Using the software, a line is drawn 5 mm apical to the smile line; it dictates the position of the crestal ridge to be reached following the alveoplasty. Subsequently, the simulated implant position and the simulated residual bone height following alveoplasty can be simultaneously evaluated on each transverse section. An alveoplasty of the anterior maxilla was performed as simulated on the software, and implants were placed accordingly. The PSTJ was always under the upper lip, even during maximum smile events. The aesthetic result was, therefore, fully satisfactory. This simple method permits the placement of the PSTJ under the upper lip with a predictable outcome; it ensures a reliable aesthetic result for the edentulous patient with a gingival smile. © 2013 Wiley Periodicals, Inc.
X-ray absorption fine structure (XAFS) analysis of titanium-implanted soft tissue.
Uo, Motohiro; Asakura, Kiyotaka; Yokoyama, Atsuro; Ishikawa, Makoto; Tamura, Kazuchika; Totsuka, Yasunori; Akasaka, Tsukasa; Watari, Fumio
2007-03-01
Tissues contacting Ti dental implants were subjected to X-ray absorption fine structure (XAFS) analysis to examine the chemical state of Ti transferred from the placed implant into the surrounding tissue. Nine tissues that contacted pure Ti cover screws for several months were excised in a second surgery whereby healing abutments were set. Six tissues that surrounded implants retrieved due to their failure were also excised. Ti distributions in the excised specimens were confirmed by X-ray scanning analytical microscopy (XSAM), and the specimens were subjected to fluorescence XAFS analysis to determine the chemical states of the low concentrations of Ti in the tissues surrounding Ti dental implants. Ti mostly existed in the metallic state and was considered to be debris derived from the abrasion of implant pieces during implant surgery. Oxidized forms of Ti, such as anatase and rutile, were also detected in a few specimens-and existed in either a pure state or mixed state with metallic Ti. It was concluded that the existence of Ti in the tissue did not cause implant failure. Moreover, the usefulness of XAFS for analysis of the chemical states of rarely contained elements in biological tissue was demonstrated.
Yamada, Masahiro; Ueno, Takeshi; Tsukimura, Naoki; Ikeda, Takayuki; Nakagawa, Kaori; Hori, Norio; Suzuki, Takeo; Ogawa, Takahiro
2012-01-01
The mechanism by which hydroxyapatite (HA)-coated titanium promotes bone–implant integration is largely unknown. Furthermore, refining the fabrication of nano-structured HA to the level applicable to the mass production process for titanium implants is challenging. This study reports successful creation of nanopolymorphic crystalline HA on microroughened titanium surfaces using a combination of flame spray and low-temperature calcination and tests its biological capability to enhance bone–implant integration. Sandblasted microroughened titanium implants and sandblasted + HA-coated titanium implants were subjected to biomechanical and histomorphometric analyses in a rat model. The HA was 55% crystallized and consisted of nanoscale needle-like architectures developed in various diameters, lengths, and orientations, which resulted in a 70% increase in surface area compared to noncoated microroughened surfaces. The HA was free from impurity contaminants, with a calcium/phosphorus ratio of 1.66 being equivalent to that of stoichiometric HA. As compared to microroughened implants, HA-coated implants increased the strength of bone–implant integration consistently at both early and late stages of healing. HA-coated implants showed an increased percentage of bone–implant contact and bone volume within 50 μm proximity of the implant surface, as well as a remarkably reduced percentage of soft tissue intervention between bone and the implant surface. In contrast, bone volume outside the 50 μm border was lower around HA-coated implants. Thus, this study demonstrated that the addition of pure nanopolymorphic crystalline HA to microroughened titanium not only accelerates but also enhances the level of bone–implant integration and identified the specific tissue morphogenesis parameters modulated by HA coating. In particular, the nanocrystalline HA was proven to be drastic in increasing osteoconductivity and inhibiting soft tissue infiltration, but the effect was limited to the immediate microenvironment surrounding the implant. PMID:22359461
Maiorana, Carlo; Beretta, Mario; Pivetti, Luca; Stoffella, Enrico; Grossi, Giovanni B.; Herford, Alan S.
2016-01-01
Background: The presence of keratinized tissue around dental implants is more than desirable either from a functional and aesthetic point of view, making soft tissue grafting a common practice in implant rehabilitation. Autogenous soft tissue grafting procedures are usually associated with high morbidity. Aim of this study was to assess the efficacy of a xenogeneic collagen matrix as a substitute for soft tissue grafting around dental implants. Methods: 15 consecutive patients underwent a vestibuloplasty and grafting, both in the mandible and the maxilla, with a collagen matrix. Results: The primary endpoint was to evaluate the resorption of the graft along with the re-epithelization grafted area. The percentage of the resorption was 44,4%, with a mean gain in vestibular height of 3 mm. Secondary endpoints evaluated the clinical appearance, the hemostatic effect and the post-operative pain. All subjects referred minimal pain with no bleeding. No adverse reaction nor infection were noted. Conclusion: This study showed that the used collagen matrix can find major interest in those patients who need a greater aesthetic outcome as the matrix has a perfect integration with the surrounding tissues. Furthermore it is strongly recommended for those patients who can bear little pain. Clinical Significance: Post-operative morbidity of autologous grafts is the biggest concern of this type of surgery. The possibility to use a soft tissue substitute is a great achievement as morbidity decreases and bigger areas can be treated in a single surgery. The present study showed the efficacy of a collagen matrix as this kind of substitute. PMID:27583050
Periodontal and peri-implant bone regeneration: clinical and histologic observations.
Artzi, Z; Zohar, R; Tal, H
1997-02-01
The principle of guided tissue regeneration by barrier membranes to restore lost periodontal tissue around natural teeth has also been used around osseointegrated implants in an attempt to restore alveolar ridge defects. While most periodontal procedures in the literature describe root coverage by mucogingival surgery, which achieves healing through soft tissue attachment, regeneration of denuded root surfaces is performed by guided tissue regeneration using expanded polytetrafluoroethylene barrier membranes and demineralized freeze-dried bone allografts as inductive/conductive materials. In this study the technique is applied in two partially exposed cylindrical hydroxyapatite-coated implants in extraction sites in one patient. Surgical reentry in both sites is presented, with histologic examination revealing new bone formation on the exposed root surface and the hydroxyapatite-coated implants.
Prados-Frutos, Juan Carlos; Manchón, Ángel; Rodríguez-Molinero, Jesús; Sammartino, Gilberto; Calvo Guirado, José Luis; Gómez-de Diego, Rafael
2016-01-01
The aim of this study was to evaluate the effectiveness of techniques for soft tissue augmentation in the placement of immediate implants with and without provisionalization and to assess the quality of the reports in the literature. Randomized clinical trials, prospective clinical trials, and case series were included in this review. Clinical questions were formulated and organised according to the PICOS strategy. An electronic search was performed in PubMed, Cochrane Central Register of Controlled Trials, Scopus, and ISI Web up until June 2016. Interexaminer agreement on eligibility (k = 0.842; p = 0.103) and quality (k = 0.933; p < 0.001) was high. Methodological approaches were assessed using criteria based on design related forms designed by the Dutch Cochrane Collaboration. Finally, 14 papers were identified. In two studies, the implant survival was 90%; for the rest of the studies it was 100%. All studies reported favourable aesthetic, biological, and radiographic outcomes. Surgical and biomechanical complications of this technique were not relevant. This technique effectively compensates for the expected loss of volume of the oral soft tissues and maintains high success rates with good aesthetic results over time. PMID:27517046
Method for Fabricating Soft Tissue Implants with Microscopic Surface Roughness
NASA Technical Reports Server (NTRS)
Banks, Bruce A. (Inventor); Rutledge, Sharon K. (Inventor)
1999-01-01
A method for fabricating soft tissue implants using a mold. The cavity surface of an initially untextured mold. made of an organic material such as epoxy. is given a thin film coating of material that has pinholes and is resistant to atomic particle bombardment. The mold cavity surface is then subjected to atomic particle bombardment, such as when placed in an isotropic atomic oxygen environment. Microscopic depressions in the mold cavity surface are created at the pinhole sites on the thin film coating. The thin film coating is removed and the mold is then used to cast the soft tissue implant. The thin film coating having pinholes may be created by chilling the mold below the dew point such that water vapor condenses upon it; distributing particles, that can partially dissolve and become attached to the mold cavity surface, onto the mold cavity surface; removing the layer of condensate, such as by evaporation; applying the thin film coating over the entire mold surface; and, finally removing the particles, such as by dissolving or brushing it off. Pinholes are created in the thin film coating at the sites previously occupied by the particles.
Calon, Tim G A; van Hoof, Marc; van den Berge, Herbert; de Bruijn, Arthur J G; van Tongeren, Joost; Hof, Janny R; Brunings, Jan Wouter; Jonhede, Sofia; Anteunis, Lucien J C; Janssen, Miranda; Joore, Manuela A; Holmberg, Marcus; Johansson, Martin L; Stokroos, Robert J
2016-11-09
Over the last years, less invasive surgical techniques with soft tissue preservation for bone conduction hearing implants (BCHI) have been introduced such as the linear incision technique combined with a punch. Results using this technique seem favorable in terms of rate of peri-abutment dermatitis (PAD), esthetics, and preservation of skin sensibility. Recently, a new standardized surgical technique for BCHI placement, the Minimally Invasive Ponto Surgery (MIPS) technique has been developed by Oticon Medical AB (Askim, Sweden). This technique aims to standardize surgery by using a novel surgical instrumentation kit and minimize soft tissue trauma. A multicenter randomized controlled trial is designed to compare the MIPS technique to the linear incision technique with soft tissue preservation. The primary investigation center is Maastricht University Medical Center. Sixty-two participants will be included with a 2-year follow-up period. Parameters are introduced to quantify factors such as loss of skin sensibility, dehiscence of the skin next to the abutment, skin overgrowth, and cosmetic results. A new type of sampling method is incorporated to aid in the estimation of complications. To gain further understanding of PAD, swabs and skin biopsies are collected during follow-up visits for evaluation of the bacterial profile and inflammatory cytokine expression. The primary objective of the study is to compare the incidence of PAD during the first 3 months after BCHI placement. Secondary objectives include the assessment of parameters related to surgery, wound healing, pain, loss of sensibility of the skin around the implant, implant extrusion rate, implant stability measurements, dehiscence of the skin next to the abutment, and esthetic appeal. Tertiary objectives include assessment of other factors related to PAD and a health economic evaluation. This is the first trial to compare the recently developed MIPS technique to the linear incision technique with soft tissue preservation for BCHI surgery. Newly introduced parameters and sampling method will aid in the prediction of results and complications after BCHI placement. Registered at the CCMO register in the Netherlands on 24 November 2014: NL50072.068.14 . Retrospectively registered on 21 April 2015 at ClinicalTrials.gov: NCT02438618 . This trial is sponsored by Oticon Medical AB.
Immediate Implant Placement in Sockets with Asymptomatic Apical Periodontitis.
Crespi, Roberto; Capparé, Paolo; Crespi, Giovanni; Lo Giudice, Giuseppe; Gastaldi, Giorgio; Gherlone, Enrico
2017-02-01
The purpose of the present study was to evaluate if the presence of granulation tissue in asymptomatic apical periodontitis compromised immediate implant placement. Patients requiring extraction of one tooth (maxillary and mandibular incisive, canine or premolar) with asymptomatic apical periodontitis, were recruited for this prospective study. They were randomly scheduled into two groups: in first group (A) including 30 teeth, reactive soft tissue was debrided before implant placement, and in second group (B) including 30 teeth, reactive soft tissue was left in the apical lesion. Implants were positioned immediately after tooth extraction, and were loaded after 3 months in both groups. Cone beam computed tomography was performed before tooth extraction and at 1-year follow-up to evaluate the radiolucency around the root apex and the implant, bucco-lingual bone levels were also checked. Sixty patients were included in this study. Sixty implants were placed immediately after tooth extraction and, at 1-year follow-up, a survival rate of 100% was reported. After one year both groups showed absence of radiolucent zone at the apical region of implants. All fresh sockets presented a buccal-palatal bone reduction in both groups after one year, even if not statistically significant differences were found between baseline bone levels and within groups. Within the limitations of the present study, the immediate placement of implants into the extraction sockets with asymptomatic apical periodontitis, in presence of primary stability, did not lead to an increased rate of complications and rendered an equally favorable type of tissue integration. © 2016 Wiley Periodicals, Inc.
Porcine dermis implants in soft-tissue reconstruction: current status
Smart, Neil J; Bryan, Nicholas; Hunt, John A; Daniels, Ian R
2014-01-01
Soft-tissue reconstruction for a variety of surgical conditions, such as abdominal wall hernia or pelvic organ prolapse, remains a challenge. There are numerous meshes available that may be simply categorized as either synthetic or biologic. Within biologic meshes, porcine dermal meshes have come to dominate the market. This review examines the current evidence for their use and the limitations of knowledge. Although there is increasing evidence to support their safety, long-term follow-up studies that support their efficacy are lacking. Numerous clinical trials that remain ongoing may help elucidate their precise role in soft-tissue reconstruction. PMID:24648721
Spontaneous progression of experimentally induced periimplantitis.
Zitzmann, N U; Berglundh, T; Ericsson, I; Lindhe, J
2004-10-01
Periimplantitis represents an inflammatory condition that is associated with the presence of a submarginal biofilm and with advanced breakdown of soft and mineralized tissues surrounding endosseous implants. Animal models have been used to describe mechanisms involved in the pathogenesis and treatment of the soft and hard tissue lesions of periimplantitis. The aim of the present experiment was to study the presence and progression of inflammatory lesions in tissues surrounding implants exposed to "experimental periimplantitis". Five Labrador dogs were used. In each dog, 2 or 3 implants were placed in both the left and right edentulous premolar regions of the mandible. Abutment connection was performed 4 months later and a plaque control regimen was initiated and maintained for 5 months. "Experimental periimplantitis" was subsequently induced by ligature placement and plaque accumulation was allowed to progress until about 40% of the height of the supporting bone had been lost. The ligatures were removed, but plaque formation was allowed to continue for an additional 12 months. Radiographs of all implant sites were obtained before and after active "experimental periimplantitis" as well as at the end of the experiment. Biopsies were harvested from the implant sites in 3 of the dogs. The tissue samples were prepared for light microscopy and the sections were used for histometric and morphometric examinations. One implant was lost during the first 2 months of "experimental periimplantitis" and two implants were lost during the 12 months that followed ligature removal. The radiographic examination indicated that varying amounts of additional bone loss occurred in the majority of the implant sites also following ligature removal. The mucosa of all implant sites harbored inflammatory lesions that extended apically of the pocket epithelium. The lesions were separated from the marginal bone by a zone of apparently normal connective tissue. A remission of the destructive inflammatory lesion in the periimplant tissues was seen in some sites following ligature removal, but in the majority of sites additional loss of supporting bone occurred. Copyright Blackwell Munksgaard, 2004
Research on dental implant and its industrialization stage
NASA Astrophysics Data System (ADS)
Dongjoon, Yang; Sukyoung, Kim
2017-02-01
Bone cell attachment to Ti implant surfaces is the most concerned issue in the clinical implant dentistry. Many attempts to achieve the fast and strong integration between bone and implant have been tried in many ways, such as selection of materials (for example, Ti, ZrO2), shape design of implant (for example, soft tissue level, bone level, taped or conical, etc), and surface modification of implants (for example, roughed. coated, hybrid), etc. Among them, a major consideration is the surface design of dental implants. The surface with proper structural characteristics promotes or induces the desirable responses of cells and tissues. To obtain such surface which has desirable cell and tissue response, a variety of surface modification techniques has been developed and employed for many years. In this review, the method and trend of surface modification will be introduced and explained in terms of the surface topography and chemistry of dental implants.
Zhang, Qixu; Hubenak, Justin; Iyyanki, Tejaswi; Alred, Erik; Turza, Kristin C.; Davis, Greg; Chang, Edward I.; Branch-Brooks, Cynthia D.; Beahm, Elisabeth K.; Butler, Charles E.
2015-01-01
Insufficient neovascularization is associated with high levels of resorption and necrosis in autologous and engineered fat grafts. We tested the hypothesis that incorporating angiogenic growth factor into a scaffold–stem cell construct and implanting this construct around a vascular pedicle improves neovascularization and adipogenesis for engineering soft tissue flaps. Poly(lactic-co-glycolic-acid/polyethylene glycol (PLGA/PEG) microspheres containing vascular endothelial growth factor (VEGF) were impregnated into collagen-chitosan scaffolds seeded with human adipose-derived stem cells (hASCs). This setup was analyzed in vitro and then implanted into isolated chambers around a discrete vascular pedicle in nude rats. Engineered tissue samples within the chambers were harvested and analyzed for differences in vascularization and adipose tissue growth. In vitro testing showed that the collagen-chitosan scaffold provided a supportive environment for hASC integration and proliferation. PLGA/PEG microspheres with slow-release VEGF had no negative effect on cell survival in collagen-chitosan scaffolds. In vivo, the system resulted in a statistically significant increase in neovascularization that in turn led to a significant increase in adipose tissue persistence after 8 weeks versus control constructs. These data indicate that our model—hASCs integrated with a collagen-chitosan scaffold incorporated with VEGF-containing PLGA/PEG microspheres supported by a predominant vascular vessel inside a chamber—provides a promising, clinically translatable platform for engineering vascularized soft tissue flap. The engineered adipose tissue with a vascular pedicle could conceivably be transferred as a vascularized soft tissue pedicle flap or free flap to a recipient site for the repair of soft-tissue defects. PMID:26410787
Zhang, Qixu; Hubenak, Justin; Iyyanki, Tejaswi; Alred, Erik; Turza, Kristin C; Davis, Greg; Chang, Edward I; Branch-Brooks, Cynthia D; Beahm, Elisabeth K; Butler, Charles E
2015-12-01
Insufficient neovascularization is associated with high levels of resorption and necrosis in autologous and engineered fat grafts. We tested the hypothesis that incorporating angiogenic growth factor into a scaffold-stem cell construct and implanting this construct around a vascular pedicle improves neovascularization and adipogenesis for engineering soft tissue flaps. Poly(lactic-co-glycolic-acid/polyethylene glycol (PLGA/PEG) microspheres containing vascular endothelial growth factor (VEGF) were impregnated into collagen-chitosan scaffolds seeded with human adipose-derived stem cells (hASCs). This setup was analyzed in vitro and then implanted into isolated chambers around a discrete vascular pedicle in nude rats. Engineered tissue samples within the chambers were harvested and analyzed for differences in vascularization and adipose tissue growth. In vitro testing showed that the collagen-chitosan scaffold provided a supportive environment for hASC integration and proliferation. PLGA/PEG microspheres with slow-release VEGF had no negative effect on cell survival in collagen-chitosan scaffolds. In vivo, the system resulted in a statistically significant increase in neovascularization that in turn led to a significant increase in adipose tissue persistence after 8 weeks versus control constructs. These data indicate that our model-hASCs integrated with a collagen-chitosan scaffold incorporated with VEGF-containing PLGA/PEG microspheres supported by a predominant vascular vessel inside a chamber-provides a promising, clinically translatable platform for engineering vascularized soft tissue flap. The engineered adipose tissue with a vascular pedicle could conceivably be transferred as a vascularized soft tissue pedicle flap or free flap to a recipient site for the repair of soft-tissue defects. Copyright © 2015 Elsevier Ltd. All rights reserved.
Soft Tissue Augmentation Using Silk Gels: An In Vitro and In Vivo Study
Etienne, Olivier; Schneider, Aurore; Kluge, Jonathan A.; Bellemin-Laponnaz, Claire; Polidori, Camille; Leisk, Gary G.; Kaplan, David L.; Garlick, Jonathan A.; Egles, Christophe
2010-01-01
Background Restoration of a three-dimensional shape with soft tissue augmentation is a challenge for surgical reconstruction and esthetic improvement of intraoral mucosa and perioral skin tissues. A connective tissue graft or free gingival graft, classically used for such indications, requires a donor site, which may lead to various clinical complications. Methods In this article, a new three-dimensional scaffold made of silk fibroin that could be of great interest for these indications was studied. Mechanical tests were conducted to characterize the physical properties of the materials. The biocompatibility of such scaffolds was positively assessed in vitro using a combination of immunostaining, 5-bromo-2′-deoxyuridine proliferation assays, and histologic staining. Finally, the shaped material was grafted subcutaneously in nude mice for a long-time implantation study. Results Human fibroblasts embedded in this material had a survival rate up to 68.4% and were able to proliferate and synthesize proteins. One month after subcutaneous implantation, the three-dimensional soft tissue augmentation was stable, and histologic analysis revealed revascularization of the area through the biomaterial. A mild inflammatory reaction disappeared after 12 weeks. Conclusion The results indicate that silk-gel material was able to create a lasting three-dimensional soft tissue augmentation and is a promising biomaterial for periodontal and maxillofacial therapies, either as a scaffold for cells or alone as a biomaterial. PMID:19905955
Vafiadis, Dean; Goldstein, Gary; Garber, David; Lambrakos, Anthony; Kowalski, Bj
2017-02-01
Preserving soft and hard tissues after extraction and implant placement is crucial for anterior esthetics. This technique will show how the information gathered from a cone-beam computed tomography (CBCT) scan of the maxillary left central incisor and an intra-oral digital impression can be merged to fabricate a CAD/CAM crown-root matrix to be used as an immediate provisional restoration that mimics the natural anatomy. Due to trauma, a left central incisor appeared to be fractured and was scheduled for extraction and implant placement. The crown-root configuration captured by the CBCT scan was merged with the digital files from an intra-oral digital impression. A CAD/CAM crown-root matrix was fabricated. Because the matrix shell was fabricated with the exact anatomy of the natural tooth, it replicated the position and three dimensional anatomy of the soft and hard tissue. It was connected to the implant with a customized provisional abutment. A digital impression of a coded healing abutment was made to fabricate the final implant abutment and final restoration. Throughout the treatment time and 36 months after completion, the thickness of tissue, emergence profile, and adjacent papilla was analyzed by clinical evaluation and photography and seemed to be maintained. The use of a pre-operative intra-oral digital scan of the clinical crown-root architecture and the CBCT scan of the bone/root anatomy, can be used together to fabricate a CAD/CAM crown-root form provisional matrix. This digital design helps in the preservation of the 3D tissue topography, as well as the final restoration. The preservation of soft and hard tissue after extraction and implant placement has always been paramount for ideal anterior implant esthetics. Using the information from digital files from CBCT scans and intra-oral scans may help the clinician identify critical anatomical features that can be replicated in the provisional and final CAD/CAM restoration. (J Esthet Restor Dent 29:13-21, 2017). © 2016 Wiley Periodicals, Inc.
[Local foreign body reactions to biodegradable implants. A classification].
Hoffmann, R; Weller, A; Helling, H J; Krettek, C; Rehm, K E
1997-08-01
Biodegradable implants are increasingly used in orthopedic and trauma surgery. Many different implants consisting of different biodegradable polymers are currently available. Different factors contribute to the biocompatibility of these implants, and local foreign-body reactions remain a matter of concern. Therefore, it is mandatory to document and compare the tissue reactions caused by various biodegradable implants in experimental or clinical studies. We have developed a standardized system of classification based on our previous experimental and clinical observations. Foreign-body reactions are differentiated into osteolysis (0-0 to 0-4), extra-articular (EA-0 to EA-4) and intraarticular (IA-0 to A-4) soft-tissue reactions.
Reddy, Vineela Katam; Parthasarathy, Harinath; Lochana, Priya
2013-01-01
Purpose: Dental implants though a successful treatment modality there exists controversies regarding the relationship between the adequacy of the keratinized gingiva (KG) and peri-implant health. The presence of an adequate amount of peri-implant KG reduces gingival inflammation and hence soft-tissue augmentation should be frequently considered. Among the various periodontal plastic surgical procedures, the apically displaced flap increases the width of keratinized tissue with reduced patient morbidity. The current study aims at evaluating the esthetic improvement in KG around dental implants applying apically positioned flap (APF) technique. Materials and Methods: A total of 10 endosseous dental implants were placed in eight systemically healthy patients. APF surgery was performed at the implant site on the buccal aspect either at the time of implant placement (one stage surgical protocol) or during the implant recovery stage (two stage surgical protocols) for increasing the width of KG and reviewed until 12 weeks post-operatively. The width of KG was evaluated at baseline and at the end of 12 weeks after surgery. Paired t-test was performed to evaluate the changes in the width of KG at baseline and at 12 weeks post-operatively. In addition, soft-tissue esthetic outcome was assessed by using visual analog scale (VAS). Results: The mean width of KG at baseline was 1.47 mm and 12 weeks post-operatively was 5.42 mm. The gain in KG from baseline was 3.95 mm with the P value of 0.000, which was highly statistically significant. The assessment of esthetic outcome using VAS gave an average score of 7.1 indicating good esthetics. Conclusion: The technique of APF yielded a significant improvement in keratinized tissue, which is both functionally and esthetically acceptable. PMID:24124297
Stage-two surgery using collagen soft tissue grafts: clinical cases and ultrastructural analysis.
Fischer, Kai R; Fickl, Stefan; Mardas, Nikos; Bozec, Laurent; Donos, Nikolaos
2014-01-01
To present the application of two different soft tissue grafts around dental implants during stage-two surgery. Furthermore, the ultrastructure of these materials is shown and discussed using scanning electron microscopy (SEM). Although soft tissue autografts may be currently regarded as the gold standard, harvesting of these grafts might lead to higher morbidity, longer chair time, and intra-/postoperative complications at the donor site. New developments in collagen scaff olds have provided an alternative to successfully replace autologous grafts in clinical practice. The SEM pictures clearly show the different composition of a bilayer scaff old (collagen matrix, CM) and a porcine acellular dermal matrix (ADM). These distinctive properties lead to different possible indications. Within the presented cases, ADM was used to augment the ridge contour and was placed into a buccal pouch to achieve complete coverage and an uneventful closed healing. On the other side, CM was left exposed to the oral cavity to successfully gain keratinized mucosa around and between two dental implants.
Potential biomedical applications of ion beam technology
NASA Technical Reports Server (NTRS)
Banks, B. A.; Weigand, A. J.; Babbush, C. A.; Vankampen, C. L.
1976-01-01
Electron bombardment ion thrusters used as ion sources have demonstrated a unique capability to vary the surface morphology of surgical implant materials. The microscopically rough surface texture produced by ion beam sputtering of these materials may result in improvements in the biological response and/or performance of implanted devices. Control of surface roughness may result in improved attachment of the implant to soft tissue, hard tissue, bone cement, or components deposited from blood. Potential biomedical applications of ion beam texturing discussed include: vascular prostheses, artificial heart pump diaphragms, pacemaker fixation, percutaneous connectors, orthopedic pros-thesis fixtion, and dental implants.
Potential biomedical applications of ion beam technology
NASA Technical Reports Server (NTRS)
Banks, B. A.; Weigand, A. J.; Van Kampen, C. L.; Babbush, C. A.
1976-01-01
Electron bombardment ion thrusters used as ion sources have demonstrated a unique capability to vary the surface morphology of surgical implant materials. The microscopically rough surface texture produced by ion beam sputtering of these materials may result in improvements in the biological response and/or performance of implanted devices. Control of surface roughness may result in improved attachment of the implant to soft tissue, hard tissue, bone cement, or components deposited from blood. Potential biomedical applications of ion beam texturing discussed include: vascular prostheses, artificial heart pump diaphragms, pacemaker fixation, percutaneous connectors, orthopedic prosthesis fixation, and dental implants.
Sieira Gil, Ramón; Pagés, Carles Martí; Díez, Eloy García; Llames, Sara; Fuertes, Ada Ferrer; Vilagran, Jesús Lopez
2015-01-01
Many types of soft tissue grafts have been used for grafting or prelaminating bone flaps for intraoral lining reconstruction. The best results are achieved when prelaminating free flaps with mucosal grafts. We suggest a new approach to obtain keratinized mucosa over a fibula flap using full-thickness, engineered, autologous oral mucosa. We report on a pilot study for grafting fibula flaps for mandibular and maxilla reconstruction with full-thickness tissue-engineered autologous oral mucosa. We describe 2 different techniques: prelaminating the fibula flap and second-stage grafting of the fibula after mandibular reconstruction. Preparation of the full-thickness tissue-engineered oral mucosa is also described. The clinical outcome of the tissue-engineered intraoral lining reconstruction and response after implant placement are reported. A peri-implant granulation tissue response was not observed when prelaminating the fibula, and little response was observed when intraoral grafting was performed. Tissue engineering represents an alternative method by which to obtain sufficient autologous tissue for reconstructing mucosal oral defects. The full-thickness engineered autologous oral mucosa offers definite advantages in terms of reconstruction planning, donor site morbidity, and quality of the intraoral soft tissue reconstruction, thereby restoring native tissue and avoiding peri-implant tissue complications. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Rodriguez, María J.; Brown, Joseph; Giordano, Jodie; Lin, Samuel J.; Omenetto, Fiorenzo G.; Kaplan, David L.
2016-01-01
In the field of soft tissue reconstruction, custom implants could address the need for materials that can fill complex geometries. Our aim was to develop a material system with optimal rheology for material extrusion, that can be processed in physiological and non-toxic conditions and provide structural support for soft tissue reconstruction. To meet this need we developed silk based bioinks using gelatin as a bulking agent and glycerol as a non-toxic additive to induce physical crosslinking. We developed these inks optimizing printing efficacy and resolution for patient-specific geometries that can be used for soft tissue reconstruction. We demonstrated in vitro that the material was stable under physiological conditions and could be tuned to match soft tissue mechanical properties. We demonstrated in vivo that the material was biocompatible and could be tuned to maintain shape and volume up to three months while promoting cellular infiltration and tissue integration. PMID:27940389
Rodriguez, María J; Brown, Joseph; Giordano, Jodie; Lin, Samuel J; Omenetto, Fiorenzo G; Kaplan, David L
2017-02-01
In the field of soft tissue reconstruction, custom implants could address the need for materials that can fill complex geometries. Our aim was to develop a material system with optimal rheology for material extrusion, that can be processed in physiological and non-toxic conditions and provide structural support for soft tissue reconstruction. To meet this need we developed silk based bioinks using gelatin as a bulking agent and glycerol as a non-toxic additive to induce physical crosslinking. We developed these inks optimizing printing efficacy and resolution for patient-specific geometries that can be used for soft tissue reconstruction. We demonstrated in vitro that the material was stable under physiological conditions and could be tuned to match soft tissue mechanical properties. We demonstrated in vivo that the material was biocompatible and could be tuned to maintain shape and volume up to three months while promoting cellular infiltration and tissue integration. Copyright © 2016 Elsevier Ltd. All rights reserved.
Hu, Chen; Gong, Ting; Lin, Weimin; Yuan, Quan; Man, Yi
2017-10-01
To evaluate bone reconstruction and soft tissue reactions at immediate implants placed into intact sockets and those with buccal bone dehiscence defects. Fifty-nine internal connection implants from four different manufacturers were immediately placed in intact sockets(non-dehiscence group, n=40), and in alveoli with buccal bone dehiscence defects: 1) Group 1(n= N10), the defect depth measured 3-5 mm from the gingival margin. 2) Group 2(n=9), the depth ranged from 5mm to 7mm. The surrounding bony voids were grafted with deproteinized bovine bone mineral (DBBM) particles. Cone beam computed tomography(CBCT) was performed immediately after surgery (T1), and at 6 months later(T2). Radiographs were taken at prosthesis placement and one year postloading(T3). Soft tissue parameters were measured at baseline (T0), prosthesis placement and T3. No implants were lost during the observation period. For the dehiscence groups, the buccal bone plates were radiographically reconstructed to comparable horizontal and vertical bone volumes compared with the non-dehiscence group. Marginal bone loss occurred between the time of final restoration and 1-year postloading was not statistically different(P=0.732) between groups. Soft tissue parameters did not reveal inferior results for the dehiscence groups. Within the limitations of this study, flapless implant placement into compromised sockets in combination with DBBM grafting may be a viable technique to reconstitute the defected buccal bone plates due to space maintenance and primary socket closure provided by healing abutments and bone grafts. Immediate implants and DBBM grafting without using membranes may be indicated for sockets with buccal bone defects. Copyright © 2017 Elsevier Ltd. All rights reserved.
Baldwin, Mark A; Clary, Chadd; Maletsky, Lorin P; Rullkoetter, Paul J
2009-10-16
Verified computational models represent an efficient method for studying the relationship between articular geometry, soft-tissue constraint, and patellofemoral (PF) mechanics. The current study was performed to evaluate an explicit finite element (FE) modeling approach for predicting PF kinematics in the natural and implanted knee. Experimental three-dimensional kinematic data were collected on four healthy cadaver specimens in their natural state and after total knee replacement in the Kansas knee simulator during a simulated deep knee bend activity. Specimen-specific FE models were created from medical images and CAD implant geometry, and included soft-tissue structures representing medial-lateral PF ligaments and the quadriceps tendon. Measured quadriceps loads and prescribed tibiofemoral kinematics were used to predict dynamic kinematics of an isolated PF joint between 10 degrees and 110 degrees femoral flexion. Model sensitivity analyses were performed to determine the effect of rigid or deformable patellar representations and perturbed PF ligament mechanical properties (pre-tension and stiffness) on model predictions and computational efficiency. Predicted PF kinematics from the deformable analyses showed average root mean square (RMS) differences for the natural and implanted states of less than 3.1 degrees and 1.7 mm for all rotations and translations. Kinematic predictions with rigid bodies increased average RMS values slightly to 3.7 degrees and 1.9 mm with a five-fold decrease in computational time. Two-fold increases and decreases in PF ligament initial strain and linear stiffness were found to most adversely affect kinematic predictions for flexion, internal-external tilt and inferior-superior translation in both natural and implanted states. The verified models could be used to further investigate the effects of component alignment or soft-tissue variability on natural and implant PF mechanics.
Mareque-Bueno, Santiago
2011-01-01
This case report describes a surgical procedure for coronally advancing the peri-implant mucosa to treat a soft tissue dehiscence in a single-tooth implant-supported restoration in combination with an acellular dermal matrix graft. The patient was a 41-year-old systemically healthy, non-smoking female. Her chief complaint pertained to the unesthetic appearance of her right lateral upper incisor, caused by recession of the mucosal margin. On examination, a 3-mm recession could be observed. The periodontium was classified as thin. A 2-mm band of keratinized peri-implant mucosa was present. Keratinized gingiva was approximately 6 mm at adjacent areas. The surgical technique included a novel incision design to coronally position the flap over an acellular dermal matrix graft. Partial coverage of the recession was achieved. After a 6-month period, tissues appeared thicker than preoperatively, with no bleeding on probing and no probing depth >2 mm. The patient was satisfied with the overall treatment result. This case report shows the possibility of achieving partial soft tissue coverage over an implant-supported restoration with the combined use of an acellular dermal matrix and a coronally positioned flap. A novel technique is presented that allowed advancing the flap over the graft in a single-tooth restoration where enough keratinized tissue was present preoperatively.
Options to avoid the second surgical site: a review of literature.
Ramachandra, Srinivas Sulugodu; Rana, Ritu; Reetika, Singhal; Jithendra, K D
2014-09-01
As esthetics gain importance, periodontal plastic surgical procedures involving soft tissue grafts are becoming commoner both around natural teeth as well as around implants. Periodontal soft tissue grafts are primarily used for the purpose of root coverage and in pre-prosthetic surgery to thicken a gingival site or to improve the crestal volume. Soft tissue grafts are usually harvested from the palate. Periodontal plastic surgical procedures involving soft tissue grafts harvested from the palate have two surgical sites; a recipient site and another donor site. Many patients are apprehensive about the soft tissue graft procedures, especially the creation of the second/donor surgical site in the palate. In the past decade, newer techniques and products have emerged which provide an option for the periodontist/patient to avoid the second surgical site. MucoMatrixX, Alloderm(®), Platelet rich fibrin, Puros(®) Dermis and Mucograft(®) are the various options available to the practicing periodontist to avoid the second surgical site. Use of these soft tissue allografts in an apprehensive patient would decrease patient morbidity and increase patient's acceptance towards periodontal plastic surgical procedures.
Greimel, Felix; Scheuerer, Christine; Gessner, Andre; Simon, Michaela; Kalteis, Thomas; Grifka, Joachim; Benditz, Achim; Springorum, Hans-Robert; Schaumburger, Jens
2017-01-01
The efficacy of antibiotic monotherapy and combination therapy in the treatment of implant-associated infection by Staphylococcus aureus was evaluated in an animal study. The femoral medullary cavity of 66 male Wistar rats was contaminated with S. aureus (ATCC 29213) and a metal device was implanted, of which 61 could be evaluated. Six treatment groups were studied: flucloxacillin, flucloxacillin in combination with rifampin, moxifloxacin, moxifloxacin in combination with rifampin, rifampin, and a control group with aqua. The treatment was applied for 14 days. After euthanasia, the bacterial counts in the periprosthetic bone, the soft tissue, and the implant-associated biofilm were measured. Both antibiotic combination treatments (moxifloxacin plus rifampin and flucloxacillin plus rifampin) achieved a highly significant decrease in microbial counts in the bone and soft tissue and in the biofilm. Mono-antibiotic treatments with either moxifloxacin or flucloxacillin were unable to achieve a significant decrease in microbial counts in bone and soft tissue or the biofilm, whilst rifampin was able to reduce the counts significantly only in the biofilm. Antibiotic resistance was measured in 1/3 of the cases in the rifampin group, whereas no resistance was measured in all other groups. The results show that combinations of both moxifloxacin and flucloxacillin plus rifampin are adequate for the treatment of periprosthetic infections due to infections with S. aureus , whereas monotherapies are not effective or not applicable due to the rapid development of antibiotic resistance. Therefore, moxifloxacin is an effective alternative in combination with rifampin for the treatment of implant-associated infections.
Tamayo, L; Acuña, D; Riveros, A L; Kogan, M J; Azócar, M I; Páez, M; Leal, M; Urzúa, M; Cerda, E
2018-04-25
The use of implants carries on a series of problems, among them infections, poor biocompatibility, high levels of cytotoxicity, and significant mechanical differences between implants and host organs that promote stress shielding effects. These problems indicate that the materials used to make implants must meet essential requirements and high standards for implantations to be successful. In this work, we present the synthesis, characterization and evaluation of the antibiofilm, mechanical, and thermal properties, and cytotoxic effect of a nanocomposite-based scaffold on polyurethane (PU) and gold nanoparticles (AuNPs) for soft tissue applications. The effect of the quantity of AuNPs on the antibacterial activity of nanocomposite scaffolds was evaluated against Staphylococcus epidermidis and Klebsiella spp., with a resulting 99.99% inhibition of both bacteria using a small quantity of nanoparticles. Cytotoxicity was evaluated with the T10 1/2 test against fibroblast cells. The results demonstrated that porous nanogold/PU scaffolds have no toxic effects on fibroblast cells to the 5 day exposition. With respect to mechanical properties, stress-strain curves showed that the compressive modulus and yield strength of PU scaffolds were significantly enhanced by AuNPs (by at least 10 times). This is due to changes in the arrangement of hard segments of PU, which increase the stiffness of the polymer. Thermogravimetric analysis showed that the degradation onset temperature rises with an increase in the quantity of AuNPs. These properties and characteristics demonstrate that porous nanogold/PU scaffolds are suitable material for use in soft tissue implants.
Maiorana, Carlo; Poli, Pier Paolo; Beretta, Mario
2018-05-21
The aim of the present case report was to show the 17-year hard and soft tissues stability of guided bone regeneration procedure associated with dental implants insertion. A 52-year-old male patient presented with a partial edentulism in the upper right maxilla. A graft consisting of deproteinized bovine bone mineral and autogenous bone stabilized by a non-resorbable expanded polytetrafluoroethylene membrane was used to reconstruct the missing bone applying the biological principles of guided bone regeneration. Dental implants were inserted simultaneously in a prosthetically driven position. Soft tissues were managed with a coronally positioned palatal sliding flap technique to obtain a primary intention healing. The healing proceeded uneventfully, and after 8 months the re-entry procedure was carried out. The defect was three-dimensionally filled by newly formed bone in an ongoing maturation phase. The regenerated bone appeared strictly integrated within the surrounding hard tissue and well vascularized. Temporary crowns were left in situ for 6 months, and definitive metal-ceramic definitive prosthesis were finally cemented and delivered to the patient. No complications occurred during the follow-up period. Clinical follow-up recalls were planned yearly, while radiological exams consisting of orthopantomographs and intra-oral radiographs were performed at 1 year, 8 years, 12 years, and 17 years after the implants insertion. The latest follow-up visit performed after 17 years from the bone augmentation procedure showed clinically stable gingival levels. No radiographic signs of peri-implantitis were observed. Mesial and distal marginal bone levels remained almost unchanged within the physiological threshold. This case report highlighted the effectiveness of the guided bone regeneration technique over a long-term follow-up. Interestingly, the use of a palatal sliding flap repositioned coronally provided sufficient amount of buccal keratinized mucosa. This may had improved the clinical stability of soft tissues preventing at the same time the likelihood of developing peri-implant disease.
The Evolution of Image-Free Robotic Assistance in Unicompartmental Knee Arthroplasty.
Lonner, Jess H; Moretti, Vincent M
2016-01-01
Semiautonomous robotic technology has been introduced to optimize accuracy of bone preparation, implant positioning, and soft tissue balance in unicompartmental knee arthroplasty (UKA), with the expectation that there will be a resultant improvement in implant durability and survivorship. Currently, roughly one-fifth of UKAs in the US are being performed with robotic assistance, and it is anticipated that there will be substantial growth in market penetration of robotics over the next decade. First-generation robotic technology improved substantially implant position compared to conventional methods; however, high capital costs, uncertainty regarding the value of advanced technologies, and the need for preoperative computed tomography (CT) scans were barriers to broader adoption. Newer image-free semiautonomous robotic technology optimizes both implant position and soft tissue balance, without the need for preoperative CT scans and with pricing and portability that make it suitable for use in an ambulatory surgery center setting, where approximately 40% of these systems are currently being utilized. This article will review the robotic experience for UKA, including rationale, system descriptions, and outcomes.
Sebők, Béla; Kiss, Gábor; Szabó, Péter J; Rigler, Dániel; Molnár, Milán L; Dobos, Gábor; Réti, Ferenc; Szőcs, Hajnal; Joób, Arpád F; Bogdán, Sándor; Szabó, György
2013-03-01
The long term effect of the human body on a pyrolytic carbon covered C/C composite maxillofacial implant (CarBulat(Tm)) was investigated by comparing the structure, the surface morphology and composition of an implant retrieved after 8 years to a sterilized, but not implanted one. Although the thickness of the carbon fibres constituting the implants did not change during the 8 year period, the surface of the implant retrieved was covered with a thin surface layer not present on the unimplanted implant. The composition of this layer is identical to the composition of the underlying carbon fibres. Calcium can only be detected on the surface as a trace element implying that the new layer is not formed by bone tissue. Residual soft tissue penetrating the bulk material between the carbon fibre bunches was found on the retrieved implant indicating the importance of the surface morphology in tissue growth and adhering to implants.
Sampatanukul, Teeratida; Serichetaphongse, Pravej; Pimkhaokham, Atiphan
2018-04-01
Improvements of soft tissue to the abutment surface results in more stable peri-implant conditions, however, few human histological studies have compared soft tissue responses around different abutment materials. To describe the peri-implant tissue around 3 abutment materials; titanium, zirconia, and gold alloy, over an 8-week healing period. Fifteen edentulous sites were treated with implants. Eight weeks later, peri-implant tissue was harvested and processed using a nonseparation resin embedded technique. The tissue attachment characteristics were assessed at clinical stages using the gingival index (GI) score, surgical stage (surgical score), and histological stage (histological attachment percentage). Additionally, the inflammatory responses were evaluated using inflammatory extent and inflammatory cellularity grades. Nonparametrical statistics were used to describe the GI and surgical scores, and analytical statistics were used to analyze the histological attachment percentages as well as the inflammatory extent and cellularity grades amongst the 3 groups. There were no statistically significant differences among the groups for GI score (P = .071) and surgical score (P = .262). Titanium and zirconia exhibited nearly similar mean histological attachment percentages while gold alloy had a significantly lower percentage (P = .004). For the inflammatory extent and cellularity grades, the odds of being one grade higher for gold alloy abutment was 5.18 and 17.8 times that of titanium abutment, respectively. However, for the zirconia abutment, the odds were 0.87 and 7.5 times higher than the titanium group. The tissue around the gold alloy abutments resulted in worse attachment conditions compared with the titanium and zirconia abutments. Inflammation tended to be higher in the tissue around the gold alloy abutments than the titanium and zirconia abutments. © 2017 Wiley Periodicals, Inc.
Ultrasound screening of periarticular soft tissue abnormality around metal-on-metal bearings.
Nishii, Takashi; Sakai, Takashi; Takao, Masaki; Yoshikawa, Hideki; Sugano, Nobuhiko
2012-06-01
Although metal hypersensitivity or pseudotumors are concerns for metal-on-metal (MoM) bearings, detailed pathologies of patterns, severity, and incidence of periprosthetic soft tissue lesions are incompletely understood. We examined the potential of ultrasound for screening of periarticular soft tissue lesions around MoM bearings. Ultrasound examinations were conducted in 88 hips (79 patients) with MoM hip resurfacings or MoM total hip arthroplasties with a large femoral head. Four qualitative ultrasound patterns were shown, including normal pattern in 69 hips, joint-expansion pattern in 11 hips, cystic pattern in 5 hips, and mass pattern in 3 hips. Hips with the latter 3 abnormal patterns showed significantly higher frequency of clinical symptoms, without significant differences of sex, duration of implantation, head sizes, and cup abduction/anteversion angles, compared with hips with normal pattern. Ultrasound examination provides sensitive screening of soft tissue reactions around MoM bearings and may be useful in monitoring progression and defining treatment for periarticular soft tissue abnormalities. Copyright © 2012 Elsevier Inc. All rights reserved.
Bonde, Mikael Juul; Stokholm, Rie; Schou, Soren; Isidor, Flemming
2013-01-01
To assess patient satisfaction and aesthetic treatment outcome of implant-supported singletooth replacements performed by dental students as part of their undergraduate curriculum 8 to 12 years after treatment. A total of 51 patients were consecutively treated by dental students with 55 implant-supported single-tooth replacements within the incisor, canine and premolar regions. The surgical and prosthetic treatment was performed by the dental students under the supervision of dentists and oral and maxillofacial surgeons, all with specific knowledge about oral implantology. The outcome measures were patient subjective evaluation of peri-implant soft tissues, implant crown, implant function and total implant treatment using a Visual Analogue Scale (VAS). The professional evaluation included the peri-implant soft tissues, implant crown and total implant treatment (combined scores, PES/WES) using the Pink Esthetic Score (PES) and the White Esthetic Score (WES), as well as the level of incisor edge/occlusal surface in relation to neighbouring teeth. A total of 42 patients with 46 implants were available for evaluation 8 to 12 years after treatment. The patients were in general satisfied with the treatment outcome and few patients had low VAS scores. Most implants were characterised by single scores of 1 or 2 resulting in a mean PES score of 8.3 (maximum 14), a mean WES score of 6.3 (maximum 10) and a mean PES/WES score of 14.6 (maximum 24). However, 33% of the implants were characterised by recession (>1 mm) of the facial soft-tissue margin. Correlation analyses involving the subjective parameters indicated that the evaluation of the total implant treatment was mainly influenced by the appearance of the implant crown and to a lesser extent by the peri-implant mucosa. There were no significant correlations between the subjective and professional evaluation. Both the subjective and professional evaluation revealed implants in infraposition. This was registered in 7% and 17% of the implants, respectively. The patient satisfaction and aesthetic outcome 8 to 12 years after treatment with implant-supported single-tooth replacements performed by dental students as part of their clinical undergraduate dental curriculum were characterised by high patient satisfaction and an acceptable aesthetic treatment outcome. Therefore, it seems acceptable to include implant therapy of straightforward cases in the clinical undergraduate curriculum, provided there is substantial supervision by trained clinicians. The study was partially supported by Nobel Biocare, Denmark. There was no conflict of interest.
De Bruyckere, Thomas; Eghbali, Aryan; Younes, Faris; De Bruyn, Hugo; Cosyn, Jan
2015-09-01
To clinically evaluate the horizontal stability of a connective tissue graft (CTG) at the buccal aspect of single implants (1); to compare actual gingival thickness between thin and thick gingival biotype (2). Periodontally healthy non-smoking patients with a single implant in the anterior maxilla (15-25) were selected for a prospective case series. All demonstrated a horizontal alveolar defect and were in need of contour augmentation by means of CTG for aesthetic reasons. Patients were enrolled 3 months after implant surgery and had been provided with a provisional screw-retained crown. CTG was inserted in the buccal mucosa via the envelope technique using one intrasulcular incision. An ultrasonic device was used to evaluate mucosal thickness (MT) at the buccal aspect. MT was assessed at t0 (before CTG), t1 (immediately after CTG), t2 (2 weeks after CTG = suture removal), t3 (3 months after CTG = permanent crown installation) and t4 (1 year after implant placement). The gingival biotype was categorized as thin or thick based on the transparency of a periodontal probe through the soft tissues while probing the buccal sulcus of the contra-lateral tooth. Gingival thickness (GT) was measured at the contra-lateral tooth using the same ultrasonic device. Thirty-seven patients (19 men, 18 women; mean age 38) met the selection criteria and consented to the treatment. Mean soft tissue gain immediately after CTG was on average 1.07 mm (SD 0.49). What remained of this tissue gain after 1 year was on average 0.97 mm (SD 0.48; 90.5%). Hence, mean soft tissue loss amounted to 0.10 mm (SD 0.23; 9.5%; p = 0.015) with no significant difference between patients with a thin or thick biotype (p ≥ 0.290). Patients with a thin biotype had a mean GT of 1.02 mm (SD 0.21), whereas GT was on average 1.32 mm (SD 0.31) in subjects with a thick biotype (p = 0.004). Connective tissue graft substantially thickens the peri-implant mucosa with acceptable stability over a 1-year period. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Piezosurgery in implant dentistry
Stübinger, Stefan; Stricker, Andres; Berg, Britt-Isabelle
2015-01-01
Piezosurgery, or the use of piezoelectric devices, is being applied increasingly in oral and maxillofacial surgery. The main advantages of this technique are precise and selective cuttings, the avoidance of thermal damage, and the preservation of soft-tissue structures. Through the application of piezoelectric surgery, implant-site preparation, bone grafting, sinus-floor elevation, edentulous ridge splitting or the lateralization of the inferior alveolar nerve are very technically feasible. This clinical overview gives a short summary of the current literature and outlines the advantages and disadvantages of piezoelectric bone surgery in implant dentistry. Overall, piezoelectric surgery is superior to other methods that utilize mechanical instruments. Handling of delicate or compromised hard- and soft-tissue conditions can be performed with less risk for the patient. With respect to current and future innovative surgical concepts, piezoelectric surgery offers a wide range of new possibilities to perform customized and minimally invasive osteotomies. PMID:26635486
Two-piece impression procedure for implant-retained orbital prostheses.
Ozcelik, Tuncer Burak; Yilmaz, Burak
2012-01-01
Obtaining an accurate impression of facial tissues with undercuts and extraoral implants has always been a challenge for both clinicians and patients. This report describes a three-step, two-piece technique that enables an accurate and comfortable impression of undercut tissues and extraoral implants in an orbital defect. An impression of the basal tissue surface of the defect area was made using a medium-body polyether impression material followed by an impression of the entire face of the patient made with a polyvinyl siloxane (PVS) impression material. First, the PVS impression material was removed; second, the impression posts were removed from the magnets; and third, the polyether impression was removed from the defect. The impression posts were attached to the implant analogs and placed in the negative spaces in the polyether impression. The polyether impression, which carries the implant analogs and impression posts, was placed in the PVS impression through the negative spaces. This technique minimizes trauma to the soft tissues and implants during impression making and also does not require additional materials.
[Experimental study of PVPP/silicone composite automatic expanded material as implants].
Yin, Wei-min; Gao, Jian-hua; Yang, Qing-fang; Lu, Feng; Ye, Jia-jia
2009-03-01
To study the feasibility of Polyvinylpolypyrrolidone (PVPP)/silicone composite automatic expanded material as implants. The PVPP hydrogel was mixed with silicone through the location at the high temperature. Implants with different ratio of PVPP to silicone were placed under the back and nose skin in 24 New Zealand rabbits. The surrounding tissue reaction, material and skin expansion were observed and compared with those with pure silicone implants. The study lasted for 200 days. Compared with pure silicone implants, the composite material could expand automatically and stop expanding at about 2 weeks after implantation. Histological study showed similar inflectional and foreign body reaction around the composite material and the pure silicone. Compared with pure silicone, the PVPP/silicone composite implant has the advantage of automatic expansion, so as to expand the soft tissue.
In vivo bone tissue response to a canasite glass-ceramic.
da Rocha Barros, V M; Salata, L A; Sverzut, C E; Xavier, S P; van Noort, R; Johnson, A; Hatton, P V
2002-07-01
The aim of this study was to determine the biocompatibility and osteoconductive potential of a high-strength canasite glass ceramic. Glass-ceramic rods were produced using the lost-wax casting technique and implanted in the mid-shafts rabbit femurs. Implants were harvested at 4, 13 and 22 weeks and prepared for light and electron microscopy. Hydroxyapatite was used as a control material. Hydroxyapatite implants were surrounded by new mineralised bone tissue after 4 weeks of implantation. The amount of bone surrounding the implant increased slightly at 13 weeks. In contrast, canasite glass and glass ceramic implants were almost entirely surrounded by soft tissue during all the time periods. Close contact between bone and canasite glass-ceramic implant without the intervening fibrous tissue was observed in only a few regions. The canasite formulation evaluated was not osteoconductive and appeared to degrade in the biological environment. It was therefore concluded that the canasite formulation used was unsuitable for use as implant. Further work is required to improve the biocompatibility of these materials with bone tissue. It is possible that this could be achieved by reducing the solubility of the glass and glass ceramic.
Arunyanak, Sirikarn P; Pollini, Adrien; Ntounis, Athanasios; Morton, Dean
2017-07-01
Esthetic outcomes associated with implant dentistry are important to both clinicians and patients. However, esthetic satisfaction may vary between the 2 groups. In order to evaluate the current publications relating to this topic, the following focused question was developed, "what are the quantitative and qualitative differences between clinician evaluations and patient perspectives in the assessment of single-tooth implant outcomes in the esthetic zone?" The purpose of this systematic review was to identify differences in esthetic satisfaction between clinicians and patients when evaluating single-tooth implant-supported restorations. An electronic search of the Medline database and Cochrane Central Register of Controlled Trials (2000 to 2014) was performed. The search was supplemented by a manual search of specific journals. A quality assessment of full-text articles was performed according to Cochrane Collaboration's tool and Newcastle-Ottawa scale for risk of bias assessment. Information regarding outcomes was collected and compared. The search term combinations identified 555 titles. Subsequent to further review, 11 publications, including 2 randomized controlled trials, were selected for inclusion. Because of the heterogeneity of the study designs, study interventions, and esthetic assessment methods, no meta-analysis was performed. The clinicians identified a satisfactory outcome in 51% to 100% for peri-implant soft tissue and 62% to 90% for implant restorations. Patients showed a mean range score of 43% to 93% for peri-implant soft tissue and 81% to 96% for implant restorations. The visual analog scale score of the dentists was always lower than that of the patients. The review identified correlations between subjective and objective assessments for the Pink Esthetic Score (PES), the Papilla Index (PI), the Implant Crown Aesthetic Index (ICAI), and the modified (mod-ICAI) indices. Clinicians are more critical of esthetic outcomes than patients. The PES and the PI correlated with the patients' responses concerning the peri-implant soft tissue. The ICAI and the mod-ICAI showed a correlation of both the peri-implant mucosa and implant-supported crown satisfaction. Thus, a comprehensive and practical index should be developed to assess the esthetic outcomes for single-tooth implant restorations in the esthetic zone. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
van der Zee, Caroline W; Moerman, Esther; Haverlag, Robert; Schepers, Tim
2015-01-01
The treatment of soft tissue defects of the ankle, combined with an implant-related infection, remains a challenge. The present case report illustrates the use of a pedicled perforator flap for soft tissue reconstruction to cover a postoperative defect at the lateral malleolus after an ankle fracture. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
The Key Points of Maintenance Therapy for Dental Implants: A Literature Review.
Pirc, Miha; Dragan, Irina F
2017-04-01
Dental implants require lifelong maintenance and care. Success is defined by biologic factors (presence of inflamed soft tissues surrounding dental implants and radiographic changes in the crestal bone levels) and mechanical factors (stability of the implant fixture and implant supported restoration, etc). Most implant failures are initiated by incipient stages of inflammatory processes, which lead to peri-mucositis and peri-implantitis. The evidence regarding the value of maintenance protocol regarding implants is sparse compared with the one for teeth. This article addresses the existing literature on processes for oral hygiene for implant care.
Cayarga, Rodrigo; Suzuki, Takanori; Kaufman, Zev
2015-01-01
Purpose. The purpose of this retrospective case series is to describe and compare different surgical techniques that can be utilized to augment the keratinized soft tissue around implant-supported overdentures. Materials and Methods. The data set was extracted as deidentified information from the routine treatment of patients at the Ashman Department of Periodontology and Implant Dentistry at New York University College of Dentistry. Eight edentulous patients were selected to be included in this study. Patients were treated for lack of keratinized tissue prior to implant placement, during the second stage surgery, and after delivery of the final prosthesis. Results. All 8 patients in this study were wearing a complete maxillary and/or mandibular denture for at least a year before the time of the surgery. One of the following surgical techniques was utilized to increase the amount of keratinized tissue: apically positioned flap (APF), pedicle graft (PG), connective tissue graft (CTG), or free gingival graft (FGG). Conclusions. The amount of keratinized tissue should be taken into consideration when planning for implant-supported overdentures. The apical repositioning flap is an effective approach to increase the width of keratinized tissue prior to the implant placement. PMID:26124833
Orthodontic extrusion for pre-implant site enhancement: Principles and clinical guidelines.
Alsahhaf, Abdulaziz; Att, Wael
2016-07-01
The aim of this paper is to provide a concise overview about the principles of pre-implant orthodontic extrusion, describe methods and techniques available and provide the clinicians with guidelines about its application. A number of reports describe orthodontic extrusion as a reliable method for pre-implant site enhancement. However, no standard protocols have been provided about the application of this technique. The literature database was searched for studies involving implant site enhancement by means of orthodontic extrusion. Information about the principles, indications and contraindications of this method, type of anchorage, force and time were obtained from the literature. Despite that the scarce data is largely limited to case reports and case series, implant site enhancement by means of orthodontic extrusion seems to be a promising option to improve soft and hard tissue conditions prior to implant placement. Orthodontic extrusion is being implemented as a treatment alternative to enhance hard and soft tissue prior to implant placement. While the current literature does not provide clear guidelines, the decision making for a specific approach seems to be based on the clinician's preferences. Clinical studies are needed to verify the validity of this treatment option. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Nikityuk, D. B.; Urakov, A. L.; Reshetnikov, A. P.; Kopylov, M. V.; Baimurzin, D. Yu.
2015-11-01
The research into dynamics of quality of clinical use in 2003 - 2012 of autologous and xenogeneic biomaterials at dental transplantation and implantation among 1,100 of adult patients was made. The analysis results show that at autologous bone transplantation implant survival is observed only in 72% of cases, and the "necessary" result of bone repair occurred only in 6 - 9 months. Transplantation of biomaterials of OsteoBiol® (materials "mp3", "Genos" and "Evolution") provided engraftment and bone regeneration in 100 % of cases and allowed the use of dental implantation immediately after transplantation even in case of reduction in the patient's alveolar crest down to 2.0 mm. Replace Select implants of Nobel Biocare® were used at plantation. In order to exclude Schneiderian membrane's perforation lighting of Highmore's sinus with the cold blue-violet light from inside at sinus elevation is recommended as well as deepening of dental instruments into the bone only until the blue-violet light appears under them. To exclude deficiency of soft tissue under the cervical part of the ceramic crown application of special anti-fissure technology involving biomaterial flap dissection and its laying around the implant is suggested.
Regeneration of Musculoskeletal Tissues by Prolonged Low-Grade Inflammation
2011-10-01
grade inflammation around a pure collagen based scaffold on implantation into the rabbit patellar tendon. Additionally, the cross-sectional areas of...the tendons treated with the implant were about 40% greater compared to the sham- operated controls. In the current study, we hypothesized that soft...was implanted into the rat patellar tendon using a minimally invasive technique and the inflammation was blocked using liposomal clodronate. The
The peri-implant esthetics: An unforgettable entity
Dhir, Sangeeta
2011-01-01
Esthetic demands in today's world of dentistry are scaling new heights, and are driven by the zest to look beautiful. The soft tissue esthetics around implants is the foci of attention, which, if failed to meet, leads to unacceptable esthetic failure. The aim of this article is to give a brief overview of the various vital parameters influencing the esthetics governing the peri-implant area. PMID:21976830
Deformable registration of x-ray to MRI for post-implant dosimetry in prostate brachytherapy
NASA Astrophysics Data System (ADS)
Park, Seyoun; Song, Danny Y.; Lee, Junghoon
2016-03-01
Post-implant dosimetric assessment in prostate brachytherapy is typically performed using CT as the standard imaging modality. However, poor soft tissue contrast in CT causes significant variability in target contouring, resulting in incorrect dose calculations for organs of interest. CT-MR fusion-based approach has been advocated taking advantage of the complementary capabilities of CT (seed identification) and MRI (soft tissue visibility), and has proved to provide more accurate dosimetry calculations. However, seed segmentation in CT requires manual review, and the accuracy is limited by the reconstructed voxel resolution. In addition, CT deposits considerable amount of radiation to the patient. In this paper, we propose an X-ray and MRI based post-implant dosimetry approach. Implanted seeds are localized using three X-ray images by solving a combinatorial optimization problem, and the identified seeds are registered to MR images by an intensity-based points-to-volume registration. We pre-process the MR images using geometric and Gaussian filtering. To accommodate potential soft tissue deformation, our registration is performed in two steps, an initial affine transformation and local deformable registration. An evolutionary optimizer in conjunction with a points-to-volume similarity metric is used for the affine registration. Local prostate deformation and seed migration are then adjusted by the deformable registration step with external and internal force constraints. We tested our algorithm on six patient data sets, achieving registration error of (1.2+/-0.8) mm in < 30 sec. Our proposed approach has the potential to be a fast and cost-effective solution for post-implant dosimetry with equivalent accuracy as the CT-MR fusion-based approach.
Gingival-colored Porcelain: A Clinical Report of an Esthetic-prosthetic Paradigm
Sonune, Shital Jalandar; Kumar, Shiv; Jadhav, Manish Shivaji; Martande, Santosh
2017-01-01
Traditionally, periodontics has been instrumental in treating hard- and soft-tissue defect. Surgical and regenerative periodontal procedures can reconstruct the three-dimensional architecture of the hard- and soft-tissue defect. However, at times, these invasive procedures leave the patients with an esthetic problem. In such situations, the defects can be treated by the prosthetic approach. A predictable esthetically pleasing and functional outcome without any surgical procedure is being a choice of treatment for many. This article discusses about the treatment for the defect of excessive hard and soft tissue, using porcelain fused to a metal restoration with gingival-colored porcelain for both tooth-supported and implant-supported fixed prosthesis. PMID:29308371
Histopathological observations of human periimplantitis lesions.
Berglundh, Tord; Gislason, Orn; Lekholm, Ulf; Sennerby, Lars; Lindhe, Jan
2004-05-01
The aim of the present study was to analyze some characteristics of advanced and progressive periimplantitis lesions in man. Soft tissue biopsies were obtained from 12 implants in six patients. The implants had been in function between 4 and 21 years and were, with one exception, located in the maxilla. The radiographic examination performed prior to biopsy revealed that all sites exhibited advanced bone loss. Further, clinical signs of severe inflammation, such as suppuration, swelling and/or fistula formation were detected in the majority of sites and seven of the 12 implants were found to be mobile at biopsy. Each biopsy was following fixation embedded in epoxy resin and sections were prepared for histometric and morphometric analysis. It was demonstrated (i). that all soft tissue units harbored large inflammatory cell infiltrates (ICT) that extended to a position apical of a pocket epithelium and (ii). that about 60% of the lesions were occupied by inflammatory cells, among which plasma cells dominated. Numerous amounts of PMN cells occurred not only in the pocket epithelium and adjacent connective tissue areas, but were also present in peri-vascular compartments in more central areas of the ICT.
Horn, Dominik; Freudlsperger, Christian; Berger, Moritz; Freier, Kolja; Ristow, Oliver; Hoffmann, Jürgen; Sakowitz, Oliver; Engel, Michael
2017-07-01
The reconstruction of large cranial and scalp defects is a surgical and esthetic challenge. Single autologous tissue transfer can be insufficient due to the defect size and the anatomic complexity of the recipient site. Alloplastic patient-specific preformed implants can be used to recover hard tissue defects of the neurocranium. Nevertheless, for long-term success adequate soft tissue support is required. In this brief clinical study, the authors describe calvarian reconstruction in a 33-year-old patient with wound healing disorder after an initial resection of ependymoma. The patient suffered from osteonecrosis and wound breakdown in the fronto-parietal region. An alloplastic polymethylmethacrylate implant for hard tissue support was manufactured based on 3-dimensional visualization of a computed tomography scan. After the resection of remaining pathologic bone from earlier surgical procedures, the alloplastic implant was inserted to achieve functional coverage of the brain. Due to anatomic variation of donor site vessels during anterolateral thigh flap preparation, the authors performed a vastus intermedius free flap as a new muscular flap for craniofacial reconstruction. The authors achieved excellent functional and esthetic results. The muscular vastus intermedius free flap in combination with a split skin graft proves to be a new alternative to the anterolateral thigh flap for soft tissue reconstruction of the neurocranium.
Okuyama, Hidenobu; Hirono, Osamu; Ishigaki, Daisuke; Yuki, Koichi; Kubota, Isao
2010-01-01
A 59-year-old man visited our hospital due to right leg edema and right leg pain. Computed tomography revealed that the circumferential enhancement of bilateral external iliac arteries by soft tissue that had similar density as the adjacent psoas muscle and that the right external iliac vein that was constricted by those tissues. The patient was diagnosed as retroperitoneal fibrosis. He underwent stent implantation to the right external iliac vein stenosis and steroid therapy. His right leg edema and pain was immediately improved after the stent implantation and he achieved remission.
Piezosurgery applied to implant dentistry: clinical and biological aspects.
Pereira, Cassiano Costa Silva; Gealh, Walter Cristiano; Meorin-Nogueira, Lamis; Garcia-Júnior, Idelmo Rangel; Okamoto, Roberta
2014-07-01
Piezosurgery is a new and modern technique of bone surgery in implantology. Selective cutting is possible for different ultrasonic frequencies acting only in hard tissues (mineralized), saving vital anatomical structures. With the piezoelectric osteotomy technique, receptor site preparation for implants, autogenous bone graft acquistition (particles and blocks), osteotomy for alveolar bone crest expansion, maxillary sinus lifting, and dental implant removal can be performed accurately and safely, providing excellent clinical and biological results, especially for osteocyte viability. The aim of this review was, through literature review, to present clinical applications of piezosurgery in implant dentistry and outline their advantages and disadvantages over conventional surgical systems. Moreover, this study addressed the biological aspects related to piezosurgery that differentiate it from those of bone tissue approaches. Overall, piezosurgery enables critical operations in simple and fully executable procedures; and effectively, areas that are difficult to access have less risk of soft tissue and neurovascular tissue damage via piezosurgery.
3D-Printed Simulation Device for Orbital Surgery.
Lichtenstein, Juergen Thomas; Zeller, Alexander Nicolai; Lemound, Juliana; Lichtenstein, Thorsten Enno; Rana, Majeed; Gellrich, Nils-Claudius; Wagner, Maximilian Eberhard
Orbital surgery is a challenging procedure because of its complex anatomy. Training could especially benefit from dedicated study models. The currently available devices lack sufficient anatomical representation and realistic soft tissue properties. Hence, we developed a 3D-printed simulation device for orbital surgery with tactual (haptic) correct simulation of all relevant anatomical structures. Based on computed tomography scans collected from patients treated in a third referral center, the hard and soft tissue were segmented and virtually processed to generate a 3D-model of the orbit. Hard tissue was then physically realized by 3D-printing. The soft tissue was manufactured by a composite silicone model of the nucleus and the surrounding tissue over a negative mold model also generated by 3D-printing. The final model was evaluated by a group of 5 trainees in oral and maxillofacial surgery (1) and a group of 5 consultants (2). All participants were asked to reconstruct an isolated orbital floor defect with a titanium implant. A stereotactic navigation system was available to all participants. Their experience was evaluated for haptic realism, correct representation of surgical approach, general handling of model, insertion of implant into the orbit, placement and fixation of implant, and usability of navigated control. The items were evaluated via nonparametric statistics (1 [poor]-5 [good]). Group 1 gave an average mark of 4.0 (±0.9) versus 4.6 (±0.6) by group 2. The haptics were rated as 3.6 (±1.1) [1] and 4.2 (±0.8) [2]. The surgical approach was graded 3.7 (±1.2) [1] and 4.0 (±1.0) [2]. Handling of the models was rated 3.5 (±1.1) [1] and 4 (±0.7) [2]. The insertion of the implants was marked as 3.7 (±0.8) [1] and 4.2 (±0.8) [2]. Fixation of the implants was also perceived to be realistic with 3.6 (±0.9) [1] and 4.2 (±0.45) [2]. Lastly, surgical navigation was rated 3.8 (±0.8) [1] and 4.6 (±0.56) [2]. In this project, all relevant hard and soft tissue characteristics of orbital anatomy could be realized. Moreover, it was possible to demonstrate that the entire workflow of an orbital procedure may be simulated. Hence, using this model training expenses may be reduced and patient security could be enhanced. Copyright © 2016 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Barboza, Eliane Porto; Stutz, Bianca; Ferreira, Vinícius Farias; Carvalho, Waldimir
2010-02-01
The biologic principle of guided bone regeneration has been successfully used to prevent bone loss in extraction sites. This study comprises 420 cases of alveolar ridge maintenance in preparation for dental implant placements. Nonexpanded polytetrafluoroethylene membranes were positioned over all extraction sites and left intentionally exposed. Lyophilized mineralized bone allografts were used to prevent membrane collapse when buccal bone walls were lost. Membranes were removed at week 4. At the time of implant placements, all sites presented soft tissue compatibility with keratinized gingiva. The mucogingival junction position seemed to be preserved. Exposed nonexpanded polytetrafluoroethylene membranes associated, or not, with bone graft provide tissue formation suitable for implant placement.
Analysis of complications following augmentation with cancellous block allografts.
Chaushu, Gavriel; Mardinger, Ofer; Peleg, Michael; Ghelfan, Oded; Nissan, Joseph
2010-12-01
Bone grafting may be associated with soft and hard tissue complications. Recipient site complications encountered using cancellous block allografts for ridge augmentation are analyzed. A total of 101 consecutive patients (62 females and 39 males; mean age 44 ± 17 years) were treated with implant-supported restoration of 137 severe atrophic alveolar ridges augmented with cancellous bone-block allografts. Alveolar ridge deficiency locations were classified as anterior maxilla (n = 58); posterior maxilla (n = 32 sinuses); posterior mandible (n = 32); and anterior mandible (n = 15). A total of 271 rough-surface implants were placed. Recipient site complications associated with block grafting (infection, membrane exposure, incision line opening, perforation of mucosa over the grafted bone, partial graft failure, total graft failure, and implant failure) were recorded. Partial and total bone-block graft failure occurred in 10 (7%) and 11 (8%) of 137 augmented sites, respectively. Implant failure rate was 12 (4.4%) of 271. Soft tissue complications included membrane exposure (42 [30.7%] of 137); incision line opening (41 [30%] of 137); and perforation of the mucosa over the grafted bone (19 [14%] of 137). Infection of the grafted site occurred in 18 (13%) of 137 bone blocks. Alveolar ridge deficiency location had a statistically significant effect on the outcome of recipient site complications. More complications were noted in the mandible compared to the maxilla. Age and gender had no statistically significant effect. Failures caused by complications were rarely noted in association with cancellous block grafting. The incidence of complications in the mandible was significantly higher. Soft tissue complications do not necessarily result in total loss of cancellous block allograft.
Regeneration of soft and hard tissue periodontal defects.
Caffesse, Raúl G; de la Rosa, Manuel; Mota, Luis F
2002-10-01
Periodontitis is characterized by the formation of periodontal pockets and bone loss. Although the basic treatment emphasizes the control of bacterial plaque, the clinician is confronted with the need to correct soft and/or hard tissue defects that develop as a consequence of the disease. This article reviews the current status of regenerative approaches in treating soft and hard tissue defects (based mainly on findings from our own laboratory) and assessed the global applicability of these procedures. Many different techniques have been suggested to treat those defects with, in general, a high degree of success. From the present knowledge it can be concluded that periodontal soft and hard tissue regeneration is possible. Treatment of areas with localized gingival recession or insufficient keratinized gingiva can be achieved with soft tissue grafts or pedicle flaps, as well as with the use of dermal allografts. The treatment of hard tissue defects around teeth and implants can be approached using different types of bone grafts, guided tissue or bone regeneration, or a combination of these. The predictability of many of these therapies, however, still needs to be improved. Since most of these techniques are sensitive, specific, and expensive, their present universal application is limited.
[Imaging of alloplastic ligament implant. An in vivo and in vitro study exemplified by Kevlar].
Wening, J V; Katzer, A; Nicolas, V; Hahn, M; Jungbluth, K H; Kratzer A [corrected to Katzer, A
1994-04-01
Neither native X-ray nor CT or NMR allow to evaluate intraarticular implantation results of Kevlar -49 directly. In animal trials, the course of an artificial ligament may only be presumed from connective tissue ingrowth. Although soft tissue structure appears much better in NMR than in CT, direct proof of ligament continuity is still impossible. As soon as the connective tissue becomes continuous, it appears clearly and allows indirect evaluation of the prosthesis, as integrity can be judged by its shape like in natural cruciate ligament. Anatomic preparations show that connective tissue fills up the small space between the two cords of a Kevlar -49 two bundle prosthesis eight weeks after implantation, so that imaging systems show only one intraarticular bundle.
Zhou, Haoyan; Goss, Monika; Hernandez, Christopher; Mansour, Joseph M; Exner, Agata
2016-05-01
Ultrasound elastography (UE) has been widely used as a "digital palpation" tool to characterize tissue mechanical properties in the clinic. UE benefits from the capability of noninvasively generating 2-D elasticity encoded maps. This spatial distribution of elasticity can be especially useful in the in vivo assessment of tissue engineering scaffolds and implantable drug delivery platforms. However, the detection limitations have not been fully characterized and thus its true potential has not been completely discovered. Characterization studies have focused primarily on the range of moduli corresponding to soft tissues, 20-600 kPa. However, polymeric biomaterials used in biomedical applications such as tissue scaffolds, stents, and implantable drug delivery devices can be much stiffer. In order to explore UE's potential to assess mechanical properties of biomaterials in a broader range of applications, this work investigated the detection limit of UE strain imaging beyond soft tissue range. To determine the detection limit, measurements using standard mechanical testing and UE on the same polydimethylsiloxane samples were compared and statistically evaluated. The broadest detection range found based on the current optimized setup is between 47 kPa and 4 MPa which exceeds the modulus of normal soft tissue suggesting the possibility of using this technique for stiffer materials' mechanical characterization. The detectable difference was found to be as low as 157 kPa depending on sample stiffness and experimental setup.
Calvo-Guirado, José Luis; López-López, Patricia Jara; Maté Sánchez de Val, José Eduardo; Mareque-Bueno, Javier; Delgado-Ruiz, Rafael Arcesio; Romanos, Georgios E
2015-07-01
The study aims to assess the soft tissue level (STL) and crestal bone level (CBL), of titanium dental implants with different mixed collar abutments configurations. This study included 48 implants with the same dimensions. They were divided into two groups of 24 implants each one: implants with a polished collar of 2 mm plus a roughened area of 0.8 mm (CONTROL) and implants with a polished collar of 0.8 mm plus a micro-threated and roughened area of 2 mm (TEST). The implants were inserted randomly in the post-extraction sockets of P2, P3, P4, and M1 bilaterally in the lower jaw of six foxhound dogs. STL and CBL were evaluated after 8 and 12 weeks by histology and histometry. All implants were clinically and histologically osseointegrated. Healing patterns examined microscopically at 8 and 12 weeks for both groups yielded similar qualitative findings for the STL evaluation, without significant differences between groups (P > 0.05). CBL was significantly higher in the buccal side in comparison with the lingual side for both groups (P < 0.05); the comparison between groups at 8 weeks showed IS-B (distance from the implant shoulder to the top of the bony crest) and IS-C (distance from the implant shoulder to the first bone-to-implant contact) values significantly higher for control group in comparison with test (P < 0.05). At 12 weeks, CBL showed increased values for both groups that were higher in controls group in comparison with test (P < 0.05). Bony crest resorption could not be avoided both at test and control sites. However, the neck conformation at the test sites reduced the buccal bone resorption. Soft tissue dimensions were similar both at the test and control sites. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
X-ray Phase Contrast Allows Three Dimensional, Quantitative Imaging of Hydrogel Implants
Appel, Alyssa A.; Larson, Jeffery C.; Jiang, Bin; Zhong, Zhong; Anastasio, Mark A.; Brey, Eric M.
2015-01-01
Three dimensional imaging techniques are needed for the evaluation and assessment of biomaterials used for tissue engineering and drug delivery applications. Hydrogels are a particularly popular class of materials for medical applications but are difficult to image in tissue using most available imaging modalities. Imaging techniques based on X-ray Phase Contrast (XPC) have shown promise for tissue engineering applications due to their ability to provide image contrast based on multiple X-ray properties. In this manuscript, we investigate the use of XPC for imaging a model hydrogel and soft tissue structure. Porous fibrin loaded poly(ethylene glycol) hydrogels were synthesized and implanted in a rodent subcutaneous model. Samples were explanted and imaged with an analyzer-based XPC technique and processed and stained for histology for comparison. Both hydrogel and soft tissues structures could be identified in XPC images. Structure in skeletal muscle adjacent could be visualized and invading fibrovascular tissue could be quantified. There were no differences between invading tissue measurements from XPC and the gold-standard histology. These results provide evidence of the significant potential of techniques based on XPC for 3D imaging of hydrogel structure and local tissue response. PMID:26487123
Canullo, Luigi; Tallarico, Marco; Botticelli, Daniele; Alccayhuaman, Karol Alí Apaza; Martins Neto, Evandro Carneiro; Xavier, Samuel Porfirio
2018-04-01
To histologically assess the hard and soft tissue changes after insertion of cleaned and activated titanium implants using plasma of argon. Eight dogs were included in this study. The mandibular premolars and first molars were extracted. For each hemi-mandible, four implants, 7 mm long and 3.3 mm of diameter, with a ZirTi surface were used. The surface of two implants was randomly treated with argon plasma (test), while the other two implants were left untreated (control). After 1 month, the same procedure was performed in the contralateral hemi-mandible. The amount of old bone, new bone, overall value of old bone plus new bone, and soft tissue was histologically evaluated. After 1 month of healing, high percentages of new bone in close contact with the implant surface were found at both the treated (60.1% ± 15.6%; 95% CI 56.5%-78.0%) and untreated (57.2% ± 13.1%; 95% CI 49.3%-67.5%) implants. Low percentages of old bone were found at this stage of healing, at both the treated (4.4% ± 3.0%; 95% CI 1.2%-5.4%) and untreated (3.4% ± 3.1%; 95% CI 0.6%-4.9%) implants. Not statistically significant differences were found between groups (p > .05). After 2 months of healing, treated implants presented a significantly higher (p = .012) new bone formation (72.5% ± 12.4%; 95% CI 69.6%-86.8%) compared to untreated sites (64.7% ± 17.3%; 95% CI 59.4%-83.3%). Controversially, no difference (p = .270) in terms of old bone was present between treated (3.1% ± 1.7%, 95% CI 1.8%-4.2%) and untreated implants (3.8% ± 1.9%, 95% CI 3.2%-5.8%). Significant differences (p = .018) in terms of total mineralized bone were found between treated (75.6% ± 13.0%, 95% CI 73.3%-91.3%) and untreated implants (68.4% ± 16.8%; 95% CI 64.2%-87.6%). Implants treated using plasma of argon was demonstrated to reach a higher bone-to-implant contact when compared to untreated implants. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Biomedical applications of ion-beam technology
NASA Technical Reports Server (NTRS)
Banks, B. A.; Weigand, A. J.; Gibbons, D. F.; Vankampen, C. L.; Babbush, C. A.
1979-01-01
Microscopically-rough surface texture of various biocompatible alloys and polymers produced by ion-beam sputtering may result in improvements in response of hard or soft tissue to various surgical implants.
Fürhauser, Rudolf; Mailath-Pokorny, Georg; Haas, Robert; Busenlechner, Dieter; Watzek, Georg; Pommer, Bernhard
2017-02-01
Implant esthetics may benefit from individualized zirconia abutments copying the emergence profile of the natural tooth and delivered within days after immediate implant insertion. To investigate the esthetic outcome of the Copy-Abutment technique using the Pink Esthetic Score (PES). A total of 77 patients with single-tooth implants in the anterior maxilla restored at the day of immediate implant placement using Copy-Abutments and provisional crowns were followed-up after 1 week, 1 month, 4 months, 6 months, 1, 2, 3, 4, and 5 years to assess implant esthetics. PES ranged between 7 and 14 (median: 13) and improved significantly between the 6 month and 1 year follow-up (p < .001), then remained stable up to the fifth year. Significant improvement was seen for the variables PES-6 soft tissue color (p = .002) and PES-7 soft tissue texture (p < .001) up to the 1 year follow-up, while PES-5 alveolar process deficiency deteriorated (p = .016). Mean mucosal recession was 0.26 ± 0.86 mm (range: 0-1.6) after 5 years and not related to gingival biotype. Copy-Abutments for immediate restoration of implants in the esthetic zone show satisfactory long-term esthetic outcomes. © 2016 Wiley Periodicals, Inc.
Tettamanti, Sandro; Millen, Christopher; Gavric, Jelena; Buser, Daniel; Belser, Urs C; Brägger, Urs; Wittneben, Julia-Gabriela
2016-06-01
A successful implant reconstruction with optimal esthetics consists of a visually pleasing prosthesis and complete and healthy surrounding soft tissue. In the current literature, numerous indices used to qualitatively assess esthetics have been described. However, studies comparing the indices and their reproducibility are scarce. The aim of this study was to compare three different esthetic indices for the evaluation of single implant-supported crowns. A total of 10 prosthodontists (P), 10 orthodontists (O), 10 general dentists (G), and 10 lay people (L) independently performed the same assessment using 30 photographs and corresponding casts with three different esthetic indices (Peri-Implant and Crown Index [PICI], Implant Crown Aesthetic Index [ICAI], "Pink Esthetic Score/White Esthetic Score [PES/WES]) and repeated the evaluations 4 weeks later. The PES/WES and the PICI showed significantly higher esthetic scores (pink, white, total) and clinical acceptance compared with the ICAI in all four groups and in both assessments. The highest intraobserver agreement was achieved using the PES/WES and the least with the ICAI. The mean Kappa per group ranged from 0.18 (group L with ICAI) to 0.63 (group G with PICI). In comparison with the ICAI, the PES/WES and PICI were more reproducible. Therefore, PES/WES and PICI seem to be more suitable as esthetic indices for single implant crowns. © 2015 Wiley Periodicals, Inc.
Gredes, Tomasz; Kubasiewicz-Ross, Pawel; Gedrange, Tomasz; Dominiak, Marzena; Kunert-Keil, Christiane
2014-08-01
New biomaterials and their various surface modifications should undergo in vitro and in vivo evaluation before clinical trials. The objective of our in vivo study was to evaluate the biocompatibility of newly created zirconium implant surfaces after implantation in the lower jaw of pigs and compare the osseointegration of these dental implants with commercially available zirconium and titanium implants. After a healing period of 12 weeks, a histological analysis of the soft and hard tissues and a histomorphometric analysis of the bone-implant contact (BIC) were performed. The implant surfaces showed an intimate connection to the adjacent bone for all tested implants. The 3 newly created zirconium implant surfaces achieved a BIC of 45% on average in comparison with a BIC of 56% from the reference zirconium implants and 35% from titanium implants. Furthermore, the new zirconium implants had a better attachment to gingival and bone tissues in the range of implant necks as compared with the reference implants. The results suggest that the new implants comparably osseointegrate within the healing period, and they have a good in vivo biocompatibility.
Hanser, Thomas; Khoury, Fouad
2016-01-01
This study evaluated volume stability after alveolar ridge contouring with free connective tissue grafts at implant placement in single-tooth gaps. A total of 52 single-tooth gaps with labial volume deficiencies in the maxilla (incisors, canines, and premolars) were consecutively treated with implants and concomitant free palatal connective tissue grafts in 46 patients between 2006 and 2009. Implants had to be covered with at least 2 mm peri-implant local bone after insertion. At implant placement, a free connective tissue graft from the palate was fixed inside a labial split-thickness flap to form an existing concave buccal alveolar ridge contour due to tissue volume deficiency into a convex shape. Standardized volumetric measurements of the labial alveolar contour using a template were evaluated before connective tissue grafting and at 2 weeks, 1 year, and 5 years after implantprosthetic incorporation. Tissue volume had increased significantly (P < .05) in all six reference points representing the outer alveolar soft tissue contour of the implant before connective tissue grafting to baseline (2 weeks after implant-prosthetic incorporation). Statistically, 50% of the reference points (P > .05) kept their volume from baseline to 1 year after prosthetic incorporation and from baseline to 5 years after prosthetic incorporation, respectively, whereas reference points located within the area of the implant sulcus showed a significant (P < .05) decrease in volume. Clinically, 5 years after prosthetic incorporation the originally concave buccal alveolar contour was still convex in all implants, leading to a continuous favorable anatomical shape and improved esthetic situation. Intraoral radiographs confirmed osseointegration and stable peri-implant parameters with a survival rate of 100% after a follow-up of approximately 5 years. Implant placement with concomitant free connective tissue grafting appears to be an appropriate long-term means to contour preexisting buccal alveolar volume deficiencies in single implants.
[Application of mini-septopal in surgery of the hand].
Zimmer, K
1992-01-01
Successful application of the Septopal in treatment of osteomyelitis has created the demand for this form of drug available for implantation into the small operation field, e.c. in the hand. The Chair and Clinic for Traumatology of the Medical Academy in Wrocław has been chosen to cooperate in the clinical trial on application of the Septopal-minichains in surgery of hand. There were 76 patients treated with the Mini-Septopal implantation. In 18 cases the osteomyelitis or active bacterial soft tissue infection gave indications for this type of treatment. In 58 cases Mini-Septopal was implanted because of high risk of infection in contaminated wounds. In both groups bacteriological examinations have been performed and statistical study revealed successful results even in primary resistant for gentamicin bacteries. Very good results of treatment let us estimate very high the usefulness of Mini-Septopal in bone and soft-tissue infections treatment, if the proper surgical procedures are performed to clean the focus of infection.
Materials and technologies for soft implantable neuroprostheses
NASA Astrophysics Data System (ADS)
Lacour, Stéphanie P.; Courtine, Grégoire; Guck, Jochen
2016-10-01
Implantable neuroprostheses are engineered systems designed to restore or substitute function for individuals with neurological deficits or disabilities. These systems involve at least one uni- or bidirectional interface between a living neural tissue and a synthetic structure, through which information in the form of electrons, ions or photons flows. Despite a few notable exceptions, the clinical dissemination of implantable neuroprostheses remains limited, because many implants display inconsistent long-term stability and performance, and are ultimately rejected by the body. Intensive research is currently being conducted to untangle the complex interplay of failure mechanisms. In this Review, we emphasize the importance of minimizing the physical and mechanical mismatch between neural tissues and implantable interfaces. We explore possible materials solutions to design and manufacture neurointegrated prostheses, and outline their immense therapeutic potential.
Herbert, Robert; Kim, Jong-Hoon; Kim, Yun Soung; Lee, Hye Moon
2018-01-01
Flexible hybrid electronics (FHE), designed in wearable and implantable configurations, have enormous applications in advanced healthcare, rapid disease diagnostics, and persistent human-machine interfaces. Soft, contoured geometries and time-dynamic deformation of the targeted tissues require high flexibility and stretchability of the integrated bioelectronics. Recent progress in developing and engineering soft materials has provided a unique opportunity to design various types of mechanically compliant and deformable systems. Here, we summarize the required properties of soft materials and their characteristics for configuring sensing and substrate components in wearable and implantable devices and systems. Details of functionality and sensitivity of the recently developed FHE are discussed with the application areas in medicine, healthcare, and machine interactions. This review concludes with a discussion on limitations of current materials, key requirements for next generation materials, and new application areas. PMID:29364861
Herbert, Robert; Kim, Jong-Hoon; Kim, Yun Soung; Lee, Hye Moon; Yeo, Woon-Hong
2018-01-24
Flexible hybrid electronics (FHE), designed in wearable and implantable configurations, have enormous applications in advanced healthcare, rapid disease diagnostics, and persistent human-machine interfaces. Soft, contoured geometries and time-dynamic deformation of the targeted tissues require high flexibility and stretchability of the integrated bioelectronics. Recent progress in developing and engineering soft materials has provided a unique opportunity to design various types of mechanically compliant and deformable systems. Here, we summarize the required properties of soft materials and their characteristics for configuring sensing and substrate components in wearable and implantable devices and systems. Details of functionality and sensitivity of the recently developed FHE are discussed with the application areas in medicine, healthcare, and machine interactions. This review concludes with a discussion on limitations of current materials, key requirements for next generation materials, and new application areas.
X-ray Phase Contrast Allows Three Dimensional, Quantitative Imaging of Hydrogel Implants
Appel, Alyssa A.; Larson, Jeffrey C.; Jiang, Bin; ...
2015-10-20
Three dimensional imaging techniques are needed for the evaluation and assessment of biomaterials used for tissue engineering and drug delivery applications. Hydrogels are a particularly popular class of materials for medical applications but are difficult to image in tissue using most available imaging modalities. Imaging techniques based on X-ray Phase Contrast (XPC) have shown promise for tissue engineering applications due to their ability to provide image contrast based on multiple X-ray properties. In this manuscript we describe results using XPC to image a model hydrogel and soft tissue structure. Porous fibrin loaded poly(ethylene glycol) hydrogels were synthesized and implanted inmore » a rodent subcutaneous model. Samples were explanted and imaged with an analyzer-based XPC technique and processed and stained for histology for comparison. Both hydrogel and soft tissues structures could be identified in XPC images. Structure in skeletal muscle adjacent could be visualized and invading fibrovascular tissue could be quantified. In quantitative results, there were no differences between XPC and the gold-standard histological measurements. These results provide evidence of the significant potential of techniques based on XPC for 3D imaging of hydrogel structure and local tissue response.« less
Tracking of adipose tissue-derived progenitor cells using two magnetic nanoparticle types
NASA Astrophysics Data System (ADS)
Kasten, Annika; Siegmund, Birte J.; Grüttner, Cordula; Kühn, Jens-Peter; Frerich, Bernhard
2015-04-01
Magnetic resonance imaging (MRI) is to be considered as an emerging detection technique for cell tracking experiments to evaluate the fate of transplanted progenitor cells and develop successful cell therapies for tissue engineering. Adipose tissue engineering using adipose tissue-derived progenitor cells has been advocated for the cure of soft tissue defects or for persistent soft tissue augmentation. Adipose tissue-derived progenitor cells were differentiated into the adipogenic lineage and labeled with two different types of magnetic iron oxide nanoparticles in varying concentrations which resulted in a concentration-dependent reduction of gene expression of adipogenic differentiation markers, adiponectin and fatty acid-binding protein 4 (FABP4), whereas the metabolic activity was not altered. As a result, only low nanoparticle concentrations for labeling were used for in vivo experiments. Cells were seeded onto collagen scaffolds and subcutaneously implanted into severe combined immunodeficient (SCID) mice. At 24 h as well as 28 days after implantation, MRI analyses were performed visualizing nanoparticle-labeled cells using T2-weighted sequences. The quantification of absolute volume of the scaffolds revealed a decrease of volume over time in all experimental groups. The distribution of nanoparticle-labeled cells within the scaffolds varied likewise over time.
Non-ionizing real-time ultrasonography in implant and oral surgery: A feasibility study.
Chan, Hsun-Liang; Wang, Hom-Lay; Fowlkes, Jeffery Brian; Giannobile, William V; Kripfgans, Oliver D
2017-03-01
Ultrasound imaging has potential to complement radiographic imaging modalities in implant and oral surgery given that it is non-ionizing and provides instantaneous images of anatomical structures. For application in oral and dental imaging, its qualities are dependent on its ability to accurately capture these complex structures. Therefore, the aim of this feasibility study was to investigate ultrasound to image soft tissue, hard tissue surface topography and specific vital structures. A clinical ultrasound scanner, paired with two 14-MHz transducers of different sizes (one for extraoral and the other for intraoral scans), was used to scan the following structures on a fresh cadaver: (i) the facial bone surface and soft tissue of maxillary anterior teeth, (ii) the greater palatine foramen; (iii) the mental foramen and (iv) the lingual nerve. Multiple measurements relevant to these structures were made on the ultrasound images and compared to those on cone-beam computed tomography (CBCT) scans and/or direct measurements. Ultrasound imaging could delineate hard tissue surfaces, including enamel, root dentin and bone as well as soft tissue with high resolution (110 μm wavelength). The greater palatine foramen, mental foramen and lingual nerve were clearly shown in ultrasound images. Merging ultrasound and CBCT images demonstrated overall spatial accuracy of ultrasound images, which was corroborated by data gathered from direct measurements. For the first time, this study provides proof-of-concept evidence that ultrasound can be a real-time and non-invasive alternative for the evaluation of oral and dental anatomical structures relevant for implant and oral surgery. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Kayani, Babar; Konan, Sujith; Pietrzak, Jurek R T; Haddad, Fares S
2018-03-27
The objective of this study was to compare macroscopic bone and soft tissue injury between robotic-arm assisted total knee arthroplasty (RA-TKA) and conventional jig-based total knee arthroplasty (CJ-TKA) and create a validated classification system for reporting iatrogenic bone and periarticular soft tissue injury after TKA. This study included 30 consecutive CJ-TKAs followed by 30 consecutive RA-TKAs performed by a single surgeon. Intraoperative photographs of the femur, tibia, and periarticular soft tissues were taken before implantation of prostheses. Using these outcomes, the macroscopic soft tissue injury (MASTI) classification system was developed to grade iatrogenic bone and soft tissue injuries. Interobserver and Intraobserver validity of the proposed classification system was assessed. Patients undergoing RA-TKA had reduced medial soft tissue injury in both passively correctible (P < .05) and noncorrectible varus deformities (P < .05); more pristine femoral (P < .05) and tibial (P < .05) bone resection cuts; and improved MASTI scores compared to CJ-TKA (P < .05). There was high interobserver (intraclass correlation coefficient 0.92 [95% confidence interval: 0.88-0.96], P < .05) and intraobserver agreement (intraclass correlation coefficient 0.94 [95% confidence interval: 0.92-0.97], P < .05) of the proposed MASTI classification system. There is reduced bone and periarticular soft tissue injury in patients undergoing RA-TKA compared to CJ-TKA. The proposed MASTI classification system is a reproducible grading scheme for describing iatrogenic bone and soft tissue injury in TKA. RA-TKA is associated with reduced bone and soft tissue injury compared with conventional jig-based TKA. The proposed MASTI classification may facilitate further research correlating macroscopic soft tissue injury during TKA to long-term clinical and functional outcomes. Copyright © 2018 Elsevier Inc. All rights reserved.
Zeno, Helios A; Buitrago, Renan L; Sternberger, Sidney S; Patt, Marisa E; Tovar, Nick; Coelho, Paulo; Kurtz, Kenneth S; Tuminelli, Frank J
2016-04-01
To compare the removal of torque values of machined implant abutment connections (internal and external) with and without soft tissue entrapment using an in vitro model. Thirty external- and 30 internal-connection implants were embedded in urethane dimethacrylate. Porcine tissue was prepared and measured to thicknesses of 0.5 and 1.0 mm. Six groups (n = 10) were studied: External- and internal-connection implants with no tissue (control), 0.5, and 1.0 mm of tissue were entrapped at the implant/abutment interface. Abutments were inserted to 20 Ncm for all six groups. Insertion torque values were recorded using a digital torque gauge. All groups were then immersed in 1 M NaOH for 48 hours to dissolve tissue. Subsequent reverse torque measurements were recorded. Mean and standard deviation were determined for each group, and one-way ANOVA and Bonferroni test were used for statistical analysis. All 60 specimens achieved a 20-Ncm insertion torque, despite tissue entrapment. Reverse torque measurements for external connection displayed a statistically significant difference (p < 0.05) between all groups with mean reverse torque values for the control (13.71 ± 1.4 Ncm), 0.5 mm (7.83 ± 2.4 Ncm), and 1.0 mm tissue entrapment (2.29 ± 1.4 Ncm) groups. Some statistically significant differences (p < 0.05) were found between internal-connection groups. In all specimens, tissue did not completely dissolve after 48 hours. External-connection implants were significantly affected by tissue entrapment; the thicker the tissue, the lower the reverse torque values noted. Internal-connection implants were less affected by tissue entrapment. © 2015 by the American College of Prosthodontists.
Teng, F; Chen, H; Xu, Y; Liu, Y; Ou, G
2018-04-01
Nowadays, most designs for the transmucosal surface of implants are machined-smooth. However, connective tissue adhered to the smooth surface of an implant has poor mechanical resistance, which can render separation of tissue from the implant interface and induce epithelial downgrowth. Modification of the transmucosal surface of implants, which can help form a good seal of connective tissue, is therefore desired. We hypothesized that anodic oxidation (AO) and polydopamine (PD) deposition could be used to enhance the attachment between an implant and peri-implant connective tissue. We tested this hypothesis in the mandibles of Beagle dogs. AO and PD were used to modify the transmucosal region of transmucosal implants (implant neck). The surface microstructure, surface roughness and elemental composition were investigated in vitro. L929 mouse fibroblasts were cultured to test the effect of PD on cell adhesion. Six Beagle dogs were used for the in vivo experiment (n = 6 dogs per group). Three months after building the edentulous animal model, four groups of implants (control, AO, PD and AO + PD) were inserted. After 4 months of healing, samples were harvested for histometric analyses. The surfaces of anodized implant necks were overlaid with densely distributed pores, 2-7 μm in size. On the PD-modified surfaces, N1s, the chemical bond of nitrogen in PD, was detected using X-ray photoelectron spectroscopy. L929 developed pseudopods more quickly on the PD-modified surfaces than on the surfaces of the control group. The in vivo experiment showed a longer connective tissue seal and a more coronally located peri-implant soft-tissue attachment in the AO + PD group than in the control group (P < .05). The modification of AO + PD on the implant neck yielded better attachment between the implant and peri-implant connective tissue. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Seniuk, A N; Mokhirev, M A
2010-01-01
Conditions for dental implantation are not always ideal that decrease the method possibilities and makes surgeons-implantologists to resort to additional interventions in order to increase the hard and soft tissues volume in the region of the planned implantation. Considerably rare an implantologist comes across with abutment tissues surplus when considerable dentoalveolar lengthening happens with expressed diminution of interalveolar distance. Orthognatic surgery as the method of surgical correction of expressed dentoalveolar lengthening of some teeth group is the most effective when there is no possibility to such deformation elimination by other methods - orthodontic or prosthetic.
Yoshioka, Kenji; Ishii, Ken; Kuramoto, Tetsuya; Nagai, Shigenori; Funao, Haruki; Ishihama, Hiroko; Shiono, Yuta; Sasaki, Aya; Aizawa, Mamoru; Okada, Yasunori; Koyasu, Shigeo; Toyama, Yoshiaki; Matsumoto, Morio
2014-01-01
Musculoskeletal infections, including surgical-site and implant-associated infections, often cause progressive inflammation and destroy areas of the soft tissue. Treating infections, especially those caused by multi-antibiotic resistant bacteria such as methicillin-resistant Staphylococcus aureus (MRSA) remains a challenge. Although there are a few animal models that enable the quantitative evaluation of infection in soft tissues, these models are not always reproducible or sustainable. Here, we successfully established a real-time, in vivo, quantitative mouse model of soft-tissue infection in the superficial gluteus muscle (SGM) using bioluminescence imaging. A bioluminescent strain of MRSA was inoculated into the SGM of BALB/c adult male mice, followed by sequential measurement of bacterial photon intensity and serological and histological analyses of the mice. The mean photon intensity in the mice peaked immediately after inoculation and remained stable until day 28. The serum levels of interleukin-6, interleukin-1 and C-reactive protein at 12 hours after inoculation were significantly higher than those prior to inoculation, and the C-reactive protein remained significantly elevated until day 21. Histological analyses showed marked neutrophil infiltration and abscesses containing necrotic and fibrous tissues in the SGM. With this SGM mouse model, we successfully visualized and quantified stable bacterial growth over an extended period of time with bioluminescence imaging, which allowed us to monitor the process of infection without euthanizing the experimental animals. This model is applicable to in vivo evaluations of the long-term efficacy of novel antibiotics or antibacterial implants.
Christensen, Jay; Fischer, Brian; Nute, Michael; Rizza, Robert
Tendon transfers are often performed in the foot and ankle. Recently, interference screws have been a popular choice owing to their ease of use and fixation strength. Considering the benefits, one disadvantage of such devices is laceration of the soft tissues by the implant threads during placement that potentially weaken the structural integrity of the grafts. A shape memory polyetheretherketone bullet-in-sheath tenodesis device uses circumferential compression, eliminating potential damage from thread rotation and maintaining the soft tissue orientation of the graft. The aim of this study was to determine the pullout strength and failure mode for this device in both a synthetic bone analogue and porcine bone models. Thirteen mature bovine extensor tendons were secured into ten 4.0 × 4.0 × 4.0-cm cubes of 15-pound per cubic foot solid rigid polyurethane foam bone analogue models or 3 porcine femoral condyles using the 5 × 20-mm polyetheretherketone soft tissue anchor. The bullet-in-sheath device demonstrated a mean pullout of 280.84 N in the bone analog models and 419.47 N in the porcine bone models. (p = .001). The bullet-in-sheath design preserved the integrity of the tendon graft, and none of the implants dislodged from their original position. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Zhou, Yalei; Yan, Zhiwei; Zhang, Hongmei; Lu, Wei; Liu, Shiyu; Huang, Xinhui; Luo, Hailang; Jin, Yan
2011-12-01
Cell/microcarrier combinations can be injected to repair tissue defects, but whether currently available microcarriers can be utilized to repair different tissue defects remains unknown. Here, we compared the suitability of fabricated micronized acellular dermal matrix (MADM), micronized small intestinal submucosa (MSIS), and gelatin microspheres as expansion and delivery scaffolds for adipose-derived mesenchymal stem cells (ADSCs). The results of MTS assay, scanning electron microscopy (SEM), and flow cytometry suggested that the three microcarriers all have good biocompatibility. Quantitative polymerase chain reaction revealed enhanced epidermal growth factor, vascular endothelial growth factor, basal fibroblast growth factor, and transforming growth factor-β expression levels after ADSCs had been cultured on MADM or MSIS for 5 days. After culturing ADSCs on microcarriers in osteogenic medium for 7 days, the expression levels of bone formation-related genes were enhanced. ADSC/microcarrier treatment accelerated wound closure. The ADSC/MADM and ADSC/MSIS combinations retained more of the original implant volume at 1 month postimplantation than ADSC/gelatin microspheres combination in soft-tissue augmentation studies. All implants displayed fibroblast and capillary vessel infiltrations; but ectopic bone formation did not occur, and the calvarial defect repair results were unfavorable. Our study demonstrates the potential utility of these microcarriers not only as a cell-culture substrate but also as a cell-transplantation vehicle for skin regeneration and soft-tissue reconstruction.
Zou, Wen; Ran, Xu; Liang, Jie; Chen, Hezhong; Luo, Jiaoming
2012-12-01
Strontium added into porous hydroxyaptite ceramics has the functions of improving its osseointegration, decreasing its dissolution rate and improving the bone density. Strontium-containing hydroxyaptite (Sr-HA) ceramics has been used as bone replacement and scaffold to treat the osteoporosis and bone default in clinic, but the mechanism of interfacial tissue response caused by the trace element Sr in Sr-HA ceramics still remains to be further studied. Four types of Sr-HA ceramic samples with different contents of Sr were prepared by microwave plasma sintering for testing the response of the soft tissue implanted in dog muscles in our laboratory. The contents of Sr element in the samples are 0 mol%, 1 mol%, 5 mol%, and 7 mol%, respectively. The samples were implanted in the muscle of the dogs for 4 weeks, 8 weeks and 12 weeks, respectively. The histological observations at the end of each period showed that the irritant ranking increased with the content of Sr in Sr-HA ceramics at the end of 12 weeks, and there were rich bone tissue in Sr-HA ceramic samples with 5 mol% Sr element. The overdose of element Sr is harmful to soft tissues. When the content of Sr in Sr-HA ceramic was below 5 mol%, the soft tissue response was very slight and the new bones were induced to grow well.
Cengiz, Murat Inanç; Kirtiloğlu, Tuğrul; Acikgoz, Gökhan; Trisi, Paolo; Wang, Hom-Lay
2012-04-01
Peri-implant mucosa is composed of 2 compartments: a marginal junctional epithelium and a zone of connective tissue attachment. Both structures consist mainly of collagen. Lathyrism is characterized by defective collagen synthesis due to inhibition of lysyl oxidase, an enzyme that is essential for interfibrillar collagen cross-linking. The lathyritic agent beta-aminoproprionitrile (β-APN) is considered a suitable agent to disrupt the connective tissue metabolism. Therefore, the purpose of this study was to assess the effect of defective connective tissue metabolism on epithelial implant interface by using β-APN created chronic lathyrism in the canine model. Two 1-year-old male dogs were included in this study. A β-APN dosage of 5 mg/0.4 mL/volume 100 g/body weight was given to the test dog for 10 months, until lathyritic symptoms developed. After this, the mandibular premolar teeth (p2, p3, p4) of both dogs were atraumatically extracted, and the investigators waited 3 months before implants were placed. In the test dog, 3 implants were placed in the left mandible, and 2 implants were placed in the right mandible. In the control dog, 2 implants were placed in the left mandibular premolar site. The dogs were sacrificed 10 months after healing. Peri-implant tissues obtained from the dogs were examined histomorphologically and histopathologically. Bone to implant contact (BIC) values and bone volumes (BV) were lower in the lathyritic group compared to the control group; however, no statistical significance was found. Significant histologic and histomorphometric changes were observed in peri-implant bone, connective tissue, and peri-implant mucosal width between test and control implants. Defective collagen metabolism such as lathyrism may negatively influence the interface between implant and surrounding soft tissue attachment.
Rieger, Elisabeth; Dupret-Bories, Agnès; Salou, Laetitia; Metz-Boutigue, Marie-Helene; Layrolle, Pierre; Debry, Christian; Lavalle, Philippe; Vrana, Nihal Engin
2015-06-07
Porous titanium implants are widely employed in the orthopaedics field to ensure good bone fixation. Recently, the use of porous titanium implants has also been investigated in artificial larynx development in a clinical setting. Such uses necessitate a better understanding of the interaction of soft tissues with porous titanium structures. Moreover, surface treatments of titanium have been generally evaluated in planar structures, while the porous titanium implants have complex 3 dimensional (3D) architectures. In this study, the determining factors for soft tissue integration of 3D porous titanium implants were investigated as a function of surface treatments via quantification of the interaction of serum proteins and cells with single titanium microbeads (300-500 μm in diameter). Samples were either acid etched or nanostructured by anodization. When the samples are used in 3D configuration (porous titanium discs of 2 mm thickness) in vivo (in subcutis of rats for 2 weeks), a better integration was observed for both anodized and acid etched samples compared to the non-treated implants. If the implants were also pre-treated with rat serum before implantation, the integration was further facilitated. In order to understand the underlying reasons for this effect, human fibroblast cell culture tests under several conditions (directly on beads, beads in suspension, beads encapsulated in gelatin hydrogels) were conducted to mimic the different interactions of cells with Ti implants in vivo. Physical characterization showed that surface treatments increased hydrophilicity, protein adsorption and roughness. Surface treatments also resulted in improved adsorption of serum albumin which in turn facilitated the adsorption of other proteins such as apolipoprotein as quantified by protein sequencing. The cellular response to the beads showed considerable difference with respect to the cell culture configuration. When the titanium microbeads were entrapped in cell-laden gelatin hydrogels, significantly more cells migrated towards the acid etched beads. In conclusion, the nanoscale surface treatment of 3D porous titanium structures can modulate in vivo integration by the accumulative effect of the surface treatment on several physical factors such as protein adsorption, surface hydrophilicity and surface roughness. The improved protein adsorption capacity of the treated implants can be further exploited by a pre-treatment with autologous serum to render the implant surface more bioactive. Titanium microbeads are a good model system to observe these effects in a 3D microenvironment and provide a better representation of cellular responses in 3D.
Pavelec, Vaclav; Rotenberg, Brian W; Maurer, Joachim T; Gillis, Edward; Verse, Thomas
2016-01-01
Many cases of obstructive sleep apnea (OSA) involve collapse of the tongue base and soft palate during sleep, causing occlusion of the upper airway and leading to oxygen desaturation. Existing therapies can be effective, but they are plagued by patient adherence issues and the invasiveness of surgical approaches. A new, minimally invasive implant for OSA has been developed, which is elastic and contracts a few weeks after deployment, stabilizing the surrounding soft tissue. The device has had good outcomes in preclinical testing; this report describes the preliminary feasibility and safety of its implementation in humans. A prospective, multicenter, single-arm feasibility study was conducted. Subjects were adults with moderate-to-severe OSA who had previously failed or refused conventional continuous positive airway pressure treatment. Intraoperative feasibility data, postoperative pain, and safety information were collected for a 30-day postoperative period. Forty subjects participated (37 men, three women; average age of 46.1 years); each received two tongue-base implants and two soft-palate implants. Surgical procedure time averaged 43 minutes. Postsurgical pain resolved readily in most cases; at 30 days post implantation, <20% of subjects reported pain, which averaged less than two out of ten. Adverse events were generally the mild and expected sequelae of a surgical procedure with general anesthesia and intraoral manipulation. The device was well tolerated. Implant extrusions were reported with soft-palate implants (n=12), while tongue-base implants required few revisions (n=2). Quantitative and qualitative sleep effectiveness outcomes (including full-night polysomnographic and quality-of-life measures) will be presented in a subsequent report. Implantation of the device was feasible. Although a relatively high rate of extrusions occurred in the now-discontinued palate implants, tongue-base implants were largely stable and well tolerated. The minimally invasive and maintenance-free implant may provide a new alternative to higher morbidity surgical procedures.
Lombardo, Giorgio; Corrocher, Giovanni; Pighi, Jacopo; Mascellaro, Anna; Marincola, Mauro; Nocini, Per Francesco
2016-06-01
The purpose of this study was to evaluate the esthetic outcome of single-tooth locking taper connection implants placed in the anterior maxilla following a postextractive nonfunctional loading protocol. This preliminary clinical study involving 16 patients evaluated the results of 21 implants placed in areas with high esthetic value. For each implant the pink esthetic score, white esthetic score, cumulative survival rate, and health status of peri-implant tissues were evaluated. The cumulative survival rate was 100% 2 years after prosthetic loading, and the mean total pink esthetic score/white esthetic score was 16.9 ± 1.14 on a maximum value of 20. There was excellent plaque control in all patients, and inflammation indices were within the norm. Within the limits of this study, this immediate nonfunctional loading protocol seems to be a successful procedure esthetically and for the maintenance of peri-implant soft tissues.
Schneider, Robert
2008-01-01
The prosthetic restoration of a missing anterior tooth with a dental implant is a challenge. Treatment coordination with a multidisciplinary team is critical in the successful outcome of this type of patient treatment. Newer surgical treatment modalities in the management of hard and soft tissues are becoming common, with very good predictability and long-term stability. Additionally, the use of advanced dental technology and materials such as sintered zirconium allows the restorative practitioner the opportunity to fabricate an esthetic, precise-fitting, biocompatible, and strong definitive prosthesis for the patient, with good longevity. The use of an all-ceramic abutment and restoration is described, along with the "soft tissue sculpting" procedure through the use of a custom provisional restoration. The relative ease and convenience of the procedure is also illustrated.
Zirconia in dental implantology: A review
Apratim, Abhishek; Eachempati, Prashanti; Krishnappa Salian, Kiran Kumar; Singh, Vijendra; Chhabra, Saurabh; Shah, Sanket
2015-01-01
Background: Titanium has been the most popular material of choice for dental implantology over the past few decades. Its properties have been found to be most suitable for the success of implant treatment. But recently, zirconia is slowly emerging as one of the materials which might replace the gold standard of dental implant, i.e., titanium. Materials and Methods: Literature was searched to retrieve information about zirconia dental implant and studies were critically analyzed. PubMed database was searched for information about zirconia dental implant regarding mechanical properties, osseointegration, surface roughness, biocompatibility, and soft tissue health around it. The literature search was limited to English language articles published from 1975 to 2015. Results: A total of 45 papers met the inclusion criteria for this review, among the relevant search in the database. Conclusion: Literature search showed that some of the properties of zirconia seem to be suitable for making it an ideal dental implant, such as biocompatibility, osseointegration, favourable soft tissue response and aesthetics due to light transmission and its color. At the same time, some studies also point out its drawbacks. It was also found that most of the studies on zirconia dental implants are short-term studies and there is a need for more long-term clinical trials to prove that zirconia is worth enough to replace titanium as a biomaterial in dental implantology. PMID:26236672
Agata, Hideki; Sándor, George K.; Haimi, Suvi
2011-01-01
ABSTRACT Objectives The aim of this study was to compare microbiological, histological, and mechanical findings from tissues around osseointergrated dental implants in patients who had undergone tumour resection and subsequent bone grafting with non bone grafted patients without a history of oral cancer and to develop an effective tool for the monitoring of the peri-implant tissues. A third aim was to assess and compare the masticatory function of the two patient groups after reconstruction with dental implants. Material and Methods A total of 20 patients were divided into 2 groups. The first group was edentulous and treated with dental implants without the need for bone grafting. The second edentulous group, with a history of oral cancer involving the mandible, received onlay bone grafts with concurrent placement of dental implants. Microbiological, histological, mechanical and biochemical assessment methods, crevicular fluid flow rate, hygiene-index, implant mobility, and the masticatory function were analysed and compared in both patient groups. Results The microbiological examinations showed no evidence of the three most common pathogenic bacteria: Porphyromonas gingivalis, Prevotella intermedius, Actinobacillus actinomycetencomitans. A causal relationship between specific microbes and peri-implant inflammation could not be found. All biopsies in both patient groups revealed early signs of soft tissue peri-implant inflammation. Conclusions The crevicular fluid volume and grade of gingival inflammation around the dental implants were related. Peri-implant tissue findings were similar in the two patient groups despite the history of oral cancer and the need for bone grafting at the time of dental implant placement. PMID:24421999
Regenerative Medicine for Periodontal and Peri-implant Diseases
Larsson, L.; Decker, A.M.; Nibali, L.; Pilipchuk, S.P.; Berglundh, T.; Giannobile, W.V.
2015-01-01
The balance between bone resorption and bone formation is vital for maintenance and regeneration of alveolar bone and supporting structures around teeth and dental implants. Tissue regeneration in the oral cavity is regulated by multiple cell types, signaling mechanisms, and matrix interactions. A goal for periodontal tissue engineering/regenerative medicine is to restore oral soft and hard tissues through cell, scaffold, and/or signaling approaches to functional and aesthetic oral tissues. Bony defects in the oral cavity can vary significantly, ranging from smaller intrabony lesions resulting from periodontal or peri-implant diseases to large osseous defects that extend through the jaws as a result of trauma, tumor resection, or congenital defects. The disparity in size and location of these alveolar defects is compounded further by patient-specific and environmental factors that contribute to the challenges in periodontal regeneration, peri-implant tissue regeneration, and alveolar ridge reconstruction. Efforts have been made over the last few decades to produce reliable and predictable methods to stimulate bone regeneration in alveolar bone defects. Tissue engineering/regenerative medicine provide new avenues to enhance tissue regeneration by introducing bioactive models or constructing patient-specific substitutes. This review presents an overview of therapies (e.g., protein, gene, and cell based) and biomaterials (e.g., resorbable, nonresorbable, and 3-dimensionally printed) used for alveolar bone engineering around teeth and implants and for implant site development, with emphasis on most recent findings and future directions. PMID:26608580
Breast implant capsule-associated squamous cell carcinoma: a report of 2 cases.
Olsen, Daniel L; Keeney, Gary L; Chen, Beiyun; Visscher, Daniel W; Carter, Jodi M
2017-09-01
The use of prosthetic implants for breast augmentation has become commonplace. Although implants do not increase the risk of conventional mammary carcinoma, they are rarely associated with anaplastic large cell lymphoma. We report 2 cases of breast implant capsule-associated squamous cell carcinoma with poor clinical outcomes. Both patients (56-year-old woman and 81-year-old woman) had long-standing implants (>25 years) and presented with acute unilateral breast enlargement. In both cases, squamous cell carcinoma arose in (focally dysplastic) squamous epithelium-lined breast implant capsules and widely invaded surrounding breast parenchyma or chest wall. Neither patient had evidence of a primary mammary carcinoma or squamous cell carcinoma at any other anatomic site. Within 1 year, one patient developed extensive, treatment-refractory, locoregional soft tissue metastasis, and the second patient developed hepatic and soft tissue metastases and died of disease. There are 2 prior reported cases of implant-associated squamous cell carcinoma in the plastic surgery literature; one provides no pathologic staging or outcome information, and the second case was a capsule-confined squamous cell carcinoma. Together, all 4 cases share notable commonalities: the patients had long-standing breast implants and presented with acute unilateral breast pain and enlargement secondary to tumors arising on the posterior aspect of squamous epithelialized implant capsules. Because of both its rarity and its unusual clinical presentation, implant capsule-associated squamous cell carcinoma may be underrecognized. The aggressive behavior of the tumors in this series underscores the importance of excluding malignancy in patients with long-standing breast implants who present with acute unilateral breast pain and enlargement. Copyright © 2017 Elsevier Inc. All rights reserved.
Rancitelli, Davide; Grossi, Giovanni Battista; Herford, Alan Scott
2016-01-01
The reconstruction of the atrophic alveolar ridges for implant placement is today a common procedure in dentistry daily practice. The surgical reconstruction provides for the optimization of the supporting bone for the implants and a restoration of the amount of keratinized gingiva for esthetic and functional reasons. In the past, tissue regeneration has been performed with autogenous bone and free gingival or connective tissue grafts. Nowadays, bone substitutes and specific collagen matrix allow for a complete restoration of the atrophic ridge without invasive harvesting procedures. A maxillary reconstruction of an atrophic ridge by means of tissue substitutes and its histological features are then presented. PMID:27022489
Maiorana, Carlo; Beretta, Mario; Rancitelli, Davide; Grossi, Giovanni Battista; Cicciù, Marco; Herford, Alan Scott
2016-01-01
The reconstruction of the atrophic alveolar ridges for implant placement is today a common procedure in dentistry daily practice. The surgical reconstruction provides for the optimization of the supporting bone for the implants and a restoration of the amount of keratinized gingiva for esthetic and functional reasons. In the past, tissue regeneration has been performed with autogenous bone and free gingival or connective tissue grafts. Nowadays, bone substitutes and specific collagen matrix allow for a complete restoration of the atrophic ridge without invasive harvesting procedures. A maxillary reconstruction of an atrophic ridge by means of tissue substitutes and its histological features are then presented.
Impact of abutment material on peri-implant soft tissue color. An in vitro study.
Sala, Leticia; Bascones-Martínez, Antonio; Carrillo-de-Albornoz, Ana
2017-09-01
The objectives of the present study is to determine the differences in peri-implant soft tissue color with the utilization of titanium, titanium gold-plated, white zirconia, Vita Classical (VC) A4-shaded zirconia, and fluorescent white zirconia abutments and to establish the influence of gingival thickness on the resulting color. Four implants were contralaterally inserted in 19 fresh pig mandibles, and the color of the peri-implant mucosa with the different abutments was spectrophotometrically measured at 1-, 2-, and 3-mm height from the margin. At 1-mm height, titanium significantly differed from all zirconia abutments in lightness (L*), chroma along red axis (a*), and chroma along yellow-blue axis (b*) parameters. At 2 mm, all zirconia abutments differed from titanium in b* but only fluorescent zirconia in a*. At 3 mm, titanium differed from VC A4-shaded and fluorescent zirconia abutments in b*. At soft tissue thicknesses <1 and 1-2 mm, titanium differed from fluorescent zirconia in a* and b* and from VC A4-shaded zirconia in b*; at thickness >2 mm, no differences were found among abutments. All abutments differed from natural teeth in a* and b* at all heights and thicknesses except for fluorescent zirconia at thickness >2 mm. The Euclidean distance (ΔΕ) differed between titanium abutments and gold, VC A4, and fluorescent zirconia at <1- and 1-2-mm thicknesses. The natural gingival color was not reproduced with any abutment at gingival thicknesses <2 mm. The worst color match was with titanium abutments and the best with fluorescent zirconia, followed by VC A4-shaded zirconia. At gingival thicknesses >2 mm, no differences were detected among abutments. This study demonstrates that the type of abutment and the gingival thickness affect the resulting peri-implant gingival color.
Belouka, Sofia-Maria; Strietzel, Frank Peter
To compare the tissue composition of augmented sites after using two different synthetic bone substitute materials, nanocrystalline and nanoporous hydroxyapatite (HA), for sinus floor elevation and augmentation. Forty-four patients received 88 titanium screw implants (Camlog Promote plus) of 4.3-mm diameter and 11- or 13-mm length, placed simultaneously during sinus floor elevation and augmentation. Nanocrystalline (Ostim) or nanoporous (NanoBone) HA were used exclusively. Bone substitute materials and implant lengths were allocated by randomization. Bone biopsy specimens were obtained from the former area of the lateral access window at implant exposure during healing abutment placement after 6 months. Biopsy specimens were prepared and examined histologically and histomorphometrically. All implants were osseointegrated at the time of exposure. Clinically and histologically, no signs of inflammation in the augmented sites were present. The histomorphometric analysis of 44 biopsy specimens revealed 31.8% ± 11.6% newly formed bone for sites augmented with nanocrystalline HA and 34.6% ± 9.2% for nanoporous HA (P = .467). The proportion of remaining bone substitute material was 28.4% ± 18.6% and 30% ± 13%, respectively (P = .453). The proportion of soft tissue within the biopsy specimens was 39.9% ± 11.1% and 35.4% ± 6.8%, respectively (P = .064). No significant differences were found between the area fractions of bone, bone substitute material, and soft tissue concerning the bone substitute material utilized. Within the present study, both synthetic bone substitute materials, nanocrystalline and nanoporous HA, were found to support bone formation in sinus floor elevation and augmentation procedures by osteoconductivity. They were not completely resorbed after 6 months. The amounts of newly formed bone, soft tissue, and bone substitute material remnants were found to be similar, indicating that both materials are likewise suitable for sinus floor elevation and augmentation procedures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neustadter, David, E-mail: david.n@navotek.co; Tune, Michal; Zaretsky, Asaph
Purpose: To analyze the stability, visibility, and histology of a novel implantable soft-tissue marker (nonradioactive and radioactive) implanted in dog prostate and rabbit liver. Methods and Materials: A total of 34 nonradioactive and 35 radioactive markers were implanted in 1 dog and 16 rabbits. Stability was assessed by measuring intermarker distance (IMD) variation relative to IMDs at implantation. The IMDs were measured weekly for 4 months in the dog and biweekly for 2-4 weeks in the rabbits. Ultrasound and X-ray imaging were performed on all subjects. Computed tomography and MRI were performed on the dog. Histologic analysis was performed onmore » the rabbits after 2 or 4 months. Results: A total of 139 measurements had a mean ({+-} SD) absolute IMD variation of 1.1 {+-} 1.1 mm. These IMD variations are consistent with those reported in the literature as due to random organ deformation. The markers were visible, identifiable, and induced minimal or no image artifacts in all tested imaging modalities. Histologic analysis revealed that all pathologic changes were highly localized and not expected to be clinically significant. Conclusions: The markers were stable from the time of implantation. The markers were found to be compatible with all common medical imaging modalities. The markers caused no significant histologic effects. With respect to marker stability, visibility, and histologic analysis these implanted fiducials are appropriate for soft-tissue target positioning in radiotherapy.« less
Bone-anchored titanium implants for auricular rehabilitation: case report and review of literature.
Gumieiro, Emne Hammoud; Dib, Luciano Lauria; Jahn, Ricardo Schmitutz; Santos Junior, João Ferreira dos; Nannmark, Ulf; Granström, Gösta; Abrahão, Márcio
2009-01-01
Osseointegrated implants have acquired an important role in the prosthetic rehabilitation of patients with craniofacial defects. The main indications are lack of local tissue for autogenous reconstruction, previous reconstruction failure and selection of this technique by the patient. This paper presents a clinical case and discusses indications and advantages of the osseointegrated implant technique for retention of auricular prostheses. Case report, Universidade Federal de São Paulo (UNIFESP). A female patient received three auricular implants after surgical resection of a hemangioma in her left ear. The time taken for osseointegration of the temporal bone was three months. After fabrication of the implant-retained auricular prosthesis, the patient was monitored for 12 months. The clinical parameters evaluated showed good postoperative healing, healthy peri-implant tissue, good hygiene and no loss of implants. Good hygiene combined with thin and immobile peri-implant soft tissues resulted in minimal complications. Craniofacial implant integration appears to be site-dependent; increasing age affects osseointegration in the temporal bone. The frequency of adverse skin reactions in peri-implant tissues is generally low. The surgical technique for rehabilitation using implant-retained auricular prostheses seems to be simple. It is associated with low rates of adverse skin reactions and long-term complications. Prostheses anchored by osseointegrated implants seem to provide better retention than do prostheses supported on spectacle frames, less risk of discoloration through the use of adhesives and better esthetic results than do prostheses anchored in the surgical cavity.
A novel adaptive algorithm for 3D finite element analysis to model extracortical bone growth.
Cheong, Vee San; Blunn, Gordon W; Coathup, Melanie J; Fromme, Paul
2018-02-01
Extracortical bone growth with osseointegration of bone onto the shaft of massive bone tumour implants is an important clinical outcome for long-term implant survival. A new computational algorithm combining geometrical shape changes and bone adaptation in 3D Finite Element simulations has been developed, using a soft tissue envelope mesh, a novel concept of osteoconnectivity, and bone remodelling theory. The effects of varying the initial tissue density, spatial influence function and time step were investigated. The methodology demonstrated good correspondence to radiological results for a segmental prosthesis.
Cashman, P M M; Baring, T; Reilly, P; Emery, R J H; Amis, A A
2010-04-01
The purpose of this study was to develop a technique to use Roentgen stereophotogrammetric analysis (RSA) to measure migration of soft-tissue structures after rotator cuff repair. RSA stereo films were obtained; images were analysed using a semi-automatic software program allowing 3D viewing of results. RSA imaging experiments were performed to validate the technique, using a glass phantom with implanted RSA beads and an animal model with steel sutures as RSA markers which were moved known distances. Repeated measurements allowed assessment of inter- and intra-observer variability at a maximum of 1.06 mm. RSA analysis of the phantom showed a variation up to 0.22 mm for static and 0.28 mm for dynamic studies. The ovine tissue specimen demonstrated that using steel sutures as RSA markers in soft tissue is feasible, although less accurate than when measuring bone motion. This novel application of RSA to measure soft tissue migration is practicable and can be extended to in vivo studies.
Biomimetic 3D tissue printing for soft tissue regeneration.
Pati, Falguni; Ha, Dong-Heon; Jang, Jinah; Han, Hyun Ho; Rhie, Jong-Won; Cho, Dong-Woo
2015-09-01
Engineered adipose tissue constructs that are capable of reconstructing soft tissue with adequate volume would be worthwhile in plastic and reconstructive surgery. Tissue printing offers the possibility of fabricating anatomically relevant tissue constructs by delivering suitable matrix materials and living cells. Here, we devise a biomimetic approach for printing adipose tissue constructs employing decellularized adipose tissue (DAT) matrix bioink encapsulating human adipose tissue-derived mesenchymal stem cells (hASCs). We designed and printed precisely-defined and flexible dome-shaped structures with engineered porosity using DAT bioink that facilitated high cell viability over 2 weeks and induced expression of standard adipogenic genes without any supplemented adipogenic factors. The printed DAT constructs expressed adipogenic genes more intensely than did non-printed DAT gel. To evaluate the efficacy of our printed tissue constructs for adipose tissue regeneration, we implanted them subcutaneously in mice. The constructs did not induce chronic inflammation or cytotoxicity postimplantation, but supported positive tissue infiltration, constructive tissue remodeling, and adipose tissue formation. This study demonstrates that direct printing of spatially on-demand customized tissue analogs is a promising approach to soft tissue regeneration. Copyright © 2015 Elsevier Ltd. All rights reserved.
Percutaneous Implants with Porous Titanium Dermal Barriers: An In Vivo Evaluation of Infection Risk
Isackson, Dorthyann; McGill, Lawrence D.; Bachus, Kent N.
2010-01-01
Osseointegrated percutaneous implants are a promising prosthetic alternative for a subset of amputees. However, as with all percutaneous implants, they have an increased risk of infection since they breach the skin barrier. Theoretically, host tissues could attach to the metal implant creating a barrier to infection. When compared with smooth surfaces, it is hypothesized that porous surfaces improve the attachment of the host tissues to the implant, and decrease the infection risk. In this study, 4 titanium implants, manufactured with a percutaneous post and a subcutaneous disk, were placed subcutaneously on the dorsum of eight New Zealand White rabbits. Beginning at four weeks post-op, the implants were inoculated weekly with 108 CFU Staphylococcus aureus until signs of clinical infection presented. While we were unable to detect a difference in the incidence of infection of the porous metal implants, smooth surface (no porous coating) percutaneous and subcutaneous components had a 7-fold increased risk of infection compared to the implants with a porous coating on one or both components. The porous coated implants displayed excellent tissue ingrowth into the porous structures; whereas, the smooth implants were surrounded with a thick, organized fibrotic capsule that was separated from the implant surface. This study suggests that porous coated metal percutaneous implants are at a significantly lower risk of infection when compared to smooth metal implants. The smooth surface percutaneous implants were inadequate in allowing a long-term seal to develop with the soft tissue, thus increasing vulnerability to the migration of infecting microorganisms. PMID:21145778
Geramy, Allahyar; Habibzadeh, Sareh
2018-02-01
This study was accomplished to assess the biomechanical state of splinting in implant-supported maxillary overdentures. Two models of maxillary overdentures were designed in SolidWorks 2011. The first model included 4 separate implants and ball abutments, whereas the second one included 4 splinted implants connected with a bar. Evaluation was performed in ANSYS Workbench software with 200 N load applied at the molar-premolar region, bilaterally. The maximum equivalent stress and strain (von Mises) was recorded and analyzed along a path between the implants in the crestal bone and the prosthetic attachments. First model presented higher values of strain in prosthetic attachment and higher values of von Mises stress in crestal bone. The second model presented higher stress concentration in the gingival tissue of premolar area (near the bar), whereas the peak stress values were reported within the most distal part of the soft tissue support of the prosthesis in the first model (unsplinted). Splinting maxillary overdentures implants is associated with significant lower stress levels in the surrounding bone tissue.
Nasal base, maxillary, and infraorbital implants--alloplastic.
Hinderer, U T
1991-01-01
The aesthetic surgery of the facial skeletal contour requires either the performance of ostectomies of excessively prominent segments or the augmentation of retruded segments with organic or synthetic material, in order to achieve balanced tridimensional relations of each segment with regard to the total facial unit. Craniomaxillofacial surgeries are necessary in major malformations or in those combined with malocclusion. In the nasal dorsum or tip, the author prefers the use of cartilage, because synthetic materials need adequate soft-tissue bulk for cover to be inserted without tension and absence of passive mobility of the reception site. For malar augmentation, first proposed by the author and independently by Spadafora in 1971, for chin augmentation up to 8 mm, and for augmentation of the mandibular angle, the author prefers silicone implants because they do not change in shape or volume, may be premanufactured or custom-made, have a similar consistency to that of bone, and do not support bacterial growth. On the other hand, autologous bone grafts adapt less to curved bony surfaces, have an erratic rate of resorption, and need an additional surgical step for removal with the corresponding morbidity and scar. Subperiosteal insertion is preferred because it confers greater stability and the cavity is easier to dissect without soft-tissue damage. Although bone erosion may occur, with over 1200 implants clinically no major change in the soft-tissue contour has been observed, nor has the author been consulted for late complication. In the malar region this may be due to the large surface of the implant and absence of muscular pressure. In the chin, an insertion over the site of the dental roots is avoided. For midface augmentation the following implants are used: (1) The premaxillary lower nasal base implant, proposed in 1971, is indicated to correct a concave midfacial profile, frequent in Asian, black, and Mestizo patients from Latin America and in Caucasian patients with maxillonasal dysplasia or Binder's syndrome, after trauma, with excessive septum and nasal spine resections, and in nasal-maxillary sequels in cleft patients. In case of dental malocclusion, orthognathic surgery is the technique of choice. A prototype implant is available in two sizes, to be inserted through a lateral incision at the base of the columella. In 108 patients two implants have been partially removed. After the first month the patient is usually well adapted to the foreign body.(ABSTRACT TRUNCATED AT 400 WORDS)
Chappuis, Vivianne; Bornstein, Michael M; Buser, Daniel; Belser, Urs
2016-09-01
To examine the influence of two different neck designs on facial bone crest dimensions in esthetic single implant sites after a 5-to-9-year follow-up analyzed by cone beam computed tomography (CBCT). Sixty-one patients with an implant-borne single crown following early implant placement in the esthetic zone were enrolled. The test group consisted of a bone level (BL) neck design exhibiting a hydrophilic micro-rough surface combined with a platform-switching interface (PS) (n = 20). The control group comprised a soft tissue level (STL) neck design exhibiting a hydrophobic machined surface with a matching butt-joint interface (n = 41). Standardized clinical, radiologic, and esthetic parameters were applied. The facial bone crest dimensions were assessed by CBCT. Soft tissue parameters and pink esthetic scores yielded no significant differences between the two designs. Major differences were only observed at the implant shoulder level. The height of the facial bone crest for the BL design was located 0.2 mm above the implant shoulder level, whereas for the STL design, its location was 1.6 mm below. The width of the peri-implant saucer-like bone defect was reduced by 40% for the BL implant design. No differences were observed 2 mm below the shoulder level. The results of this comparative study suggest better crestal bone stability on the facial aspect of single implant sites in the esthetic zone for a BL design with a platform-switching concept when compared with STL implants with a butt-joint interface. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Stein, Jamal M; Hammächer, Christian; Said-Yekta Michael, Sareh
2017-09-15
The aim of this study was to evaluate the clinical outcomes of a concept for non-surgical peri-implantitis combining stepwise mechanical debridement measures with adjuvant Povidone-iodine application with and without systemic antibiotics. 45 patients with chronic periodontitis comprising 164 screw-typed implants with peri-implantitis were included. Peri-implantitis was defined as radiographic bone loss of >2 mm, probing pocket depth (PD) ≥5 mm with bleeding on probing (BOP). Stepwise treatment of implants was performed with ultrasonic debridement, soft tissue curettage (STC), glycine powder air polishing (GPAP) and a repeated submucosal application of Povidone-iodine. Teeth with PD >4mm were treated simultaneously according to the same concept except STC. In cases with severe periodontitis (N = 24), amoxicillin and metronidazole (AM) were prescribed for 7 days. After 12 months, implants treated without AM showed significant reductions (p<0.05) of mean PD (1.4 ± 0.7 mm), CAL (1.3 ± 0.8 mm) and BOP (33.4 ± 17.2%). In deep pockets (PD >6mm) changes of mean PD (2.3 ± 1.3 mm), CAL (2.0 ± 1.6 mm) and BOP (44.0 ± 41.7%) were more pronounced. Intake of AM did not significantly influence the changes of these parameters. However, the reduction of implant sites with PD >4 mm and BOP was significantly higher in patients with AM than in those without AM (31.8 ± 12.6% vs. 20.8 ± 14.7%; p<0.05). The combination of ultrasonic debridement, STC and GPAP with adjuvant Povidone-iodine led to significant clinical improvements at implants. Systemic antibiotics had limited effects on the reduction of persisting implant sites with treatment need.
Evaluation of the success and complication rates of self-drilling orthodontic mini-implants.
Gurdan, Z; Szalma, J
2018-05-01
Orthodontic mini-implants are important devices for successful anchorage management in orthodontics; however, the survival of these devices depends on several clinical factors. The aim of our study was to calculate the success and complication rates of orthodontic mini-implants. In this retrospective study, patients of our orthodontic department were enrolled, getting overall 59 orthodontic mini-implants during their orthodontic treatment in a 2-year period. Every patient had one or more of the 1.6 mm × 8 mm in size self-drilling mini-implants (Jeil Dual Top Anchor System, Jeil Medical Corp., Seoul, Korea). Screw loading was performed immediately after insertions, keeping tension forces under 150 g. Soft tissue and bone infections, implant mobility and screw loss, implant fracture, and neighboring tooth injury were registered. Relationships between variables were tested using the Chi-square test for statistical significance. The success rate of the orthodontic mini-implants was 89.8% in this study while the average loading period was 8.1 months. Soft-tissue infections varied between 6.3% and 33.3% of the cases while screw mobility varied between 3.1% and 20.8% of the cases regarding the anatomic localization. Screw mobility was significantly more frequent in the buccal fold than in the palate (P = 0.034). Screw mobility was significantly more frequent in the buccal fold than in the palate (P = 0.034) and screw mobility was found more frequently in case of intrusions than by extrusions (P = 0.036). The overall success rate of mini-implants was found acceptable in this study, however, screw mobility in the buccal fold showed a high incidence, suggesting the thorough consideration of the immediate loading by buccal mini-implants.
Bone-level implants placed in the anterior maxilla: an open-label, single-arm observational study
2017-01-01
Purpose This study assessed marginal bone remodeling and soft tissue esthetics after the loading of single bone-level implants in the anterior maxilla. Methods An open, single-arm observational clinical trial with 3 years of follow-up was performed, including 22 implants. The patients presented with a single tooth gap in the anterior maxilla (tooth positions 14–24), with natural or restored adjacent teeth. An implant was placed at least 8 weeks post-extraction and healed submerged for 6 weeks. After the second-stage operation, a fixed provisional prosthesis was provided. The final restoration was placed 6 months after the provisional restoration. The time of the provisional crown connection was considered to be the baseline in this study. Esthetic parameters and the marginal bone level were assessed at 6, 12, 24, and 36 months. Results All implants were well integrated in the bone. A statistically significant increase was found in the mean implant stability quotient between the time of the provisional prosthesis and the time of the final prosthesis. Most implants (95.5%) revealed marginal bone resorption (<0.5 mm), and just 1 implant (4.5%) showed a change of 2.12 mm from baseline to 36 months (mean 0.07±0.48 mm), while the crestal bone level decreased significantly, from 2.34±0.93 mm at baseline to 1.70±1.10 mm at 36 months. The facial gingival margin and papilla were stable and the esthetic scores indicated high patient and dentist satisfaction. Conclusions Platform-switching bone-level implants placed in maxillary single-tooth gaps resulted in successful osseointegration with minimal marginal bone resorption. The peri-implant soft tissue was also esthetically satisfying and stable. PMID:29093988
Noh, Kwantae; Choi, Woo-Jin
2013-01-01
Traumatic defects are mostly accompanied by hard and soft tissue loss. This report describes the surgical and prosthetic treatment of a patient with post-traumatic mandibular defect. A split-thickness skin graft was performed prior to implant placement and prefabricated acrylic stent was placed to hold the graft in place. The esthetic and functional demands of the patient were fulfilled by implant-supported screw-retained fixed prosthesis using CAD-CAM technology. PMID:23508120
Busse, B; Niecke, M; Püschel, K; Delling, G; Katzer, A; Hahn, M
2007-01-01
Periprosthetic tissue was analysed by the combination of different investigation techniques without destruction. The localisation and geometry of polyethylene abrasion particles were determined quantitatively to differentiate between abrasion due to function and abrasion due to implant loosening. Non-polyethylene particles from implant components which contaminate the tissue were micro-analytically measured. The results will help us to understand loosening mechanisms and thus lead to implant optimisations. A non-destructive particle analysis using highly sensitive proton-induced X-ray emission (PIXE) was developed to achieve a better histological allocation. Five autopsy cases with firmly fitting hip endoprosthesis (2 x Endo-Modell Mark III, 1 x St. Georg Mark II, LINK, Germany; 2 x Spongiosa Metal II, ESKA, Germany) were prepared as ground tissue specimens. Wear investigations were accomplished with a combined application of different microscopic techniques and microanalysis. The abrasion due to implant loosening was histologically evaluated on 293 loosened cup implants (St. Georg Mark II, LINK, Germany). Wear particles are heterogeneously distributed in the soft tissue. In cases of cemented prostheses, cement particles are dominating whereas metal particles could rarely be detected. The concentration of the alloy constituent cobalt (Co) is increased in the mineralised bone tissue. The measured co-depositions depend on the localisation and/or lifetime of an implant. Functional polyethylene (PE) abrasion needs to be differentiated from PE abrasion of another genesis (loosening, impingement) morphologically and by different tissue reactions. In the past a reduction of abrasion was targeted primarily by the optimisation of the bearing surfaces and tribology. The interpretation of our findings indicates that different mechanisms of origin in terms of tissue contamination with wear debris and the alloy should be included in the improvement of implants or implantation techniques.
Zhang, Lei; Ding, Qian; Liu, Cunrui; Sun, Yannan; Xie, Qiufei; Zhou, Yongsheng
2016-01-01
This systematic review attempted to determine the survival rate of implants placed in bone flaps in jaw rehabilitation and the functional gains and the most common complications related to these implants. An electronic search was undertaken of PubMed, EMBASE, and CNKI records from 1990 through July 2014. Two independent examiners read the titles and abstracts of the results to identify studies that met the inclusion criteria. Subsequently, the reference lists of the selected publications were hand searched. Descriptive statistics were used to report all data related to the survival rate of implants placed in bone flaps in jaw rehabilitation, the functional gains, and complications. A total of 20 studies were included for systematic review without repetition. The mean follow-up time after implant placement ranged from 1.75 to 9.5 years. Within the limitations of available studies, the survival rate of implants placed in bone flaps in jaw rehabilitation ranged from 82.4% to 100%. Of the 20 included studies, 15 reported a survival rate higher than 90%. The cumulative survival rate was 93.2%, with the longest follow-up time being 12.9 years. The most common complications related to these implants were peri-implant bone resorption or peri-implant inflammation, and peri-implant soft tissue proliferation. The main factors associated with the survival rate of implants in bone flaps were reported as time of implant placement and radiotherapy. Despite some persistent soft tissue problems and implant loss, most patients reached a satisfactory functional and esthetic outcome, as evaluated by clinical examination and subjectively by the patients at interview. Implant-supported dental prosthetic rehabilitation in reconstructed jaws improved the quality of life in terms of speech, nutrition, oral competence, and facial appearance. Placement of implants in bone flaps in jaw rehabilitation was demonstrated to be a reliable technique with a high survival rate. Multicentered randomized controlled clinical trials and longer clinical studies should be undertaken in this area.
Sanz-Martín, Ignacio; Sanz-Sánchez, Ignacio; Carrillo de Albornoz, Ana; Figuero, Elena; Sanz, Mariano
2018-01-01
The purpose of this systematic review was to evaluate the impact of the abutment characteristics on peri-implant tissue health and to identify the most suitable material and surface characteristics. A protocol was developed aimed to answer the following focused question: "Which is the effect of the modification of the abutment design in regard to the maintenance of the peri-implant soft tissue health?" Further subanalysis aimed to investigate the impact of the abutment material, macroscopic design, surface topography and surface manipulation. Randomised controlled trials (RCTs) with a follow-up of at least 6 months after implant loading were considered as inclusion criteria. Meta-analyses were performed whenever possible. Nineteen final publications from thirteen investigations were included. The results from the meta-analysis indicated that zirconia abutments (Zi) experienced less increase in BOP values over time [n = 3; WMD = -26.96; 95% CI (-45.00; -8.92); p = .003] and less plaque accumulation [n = 1; MD = -20.00; 95% CI (-41.47; 1.47); p = .068] when compared with titanium abutments (Ti). Bone loss was influenced by the method of abutment decontamination [n = 1; MD = -0.44; 95% CI (-0.65; -0.23); p < .001]. The rest of the studied outcomes did not show statistically significant differences. The macroscopic design, the surface topography and the manipulation of the implant abutment did not have a significant influence on peri-implant inflammation. In contrast, the abutment material demonstrated increased BOP values over time for Ti when compared to Zi abutments. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Fracol, Megan; Grim, Michelle; Lanier, Steven T; Fine, Neil A
2018-03-01
The latissimus dorsi myocutaneous flap is a reliable and frequently used option to bring vascularized skin and soft tissue to improve the stability and aesthetic result in breast reconstruction. Standard techniques with skin paddle inset in a horizontal or oblique fashion preferentially improve anterior projection (when inset at the mastectomy scar) or lower pole and inframammary fold constriction (when inset into the inframammary fold). Here, the authors describe a modification for inset of the latissimus dorsi myocutaneous flap that improves both anterior projection and lower pole/inframammary fold constriction, and also allows the latissimus muscle to fan out and provide complete implant coverage. The vertical inset modification brings new skin and soft tissue into both the inferior pole and the central mastectomy scar, allowing simultaneous improvement in both areas and full use of the latissimus muscle to cover the implant or expander. Therapeutic, IV.
Magrin, Gabriel Leonardo; Sigua-Rodriguez, Eder Alberto; Goulart, Douglas Rangel; Asprino, Luciana
2015-01-01
The piezosurgery has been used with increasing frequency and applicability by health professionals, especially those who deal with dental implants. The concept of piezoelectricity has emerged in the nineteenth century, but it was applied in oral surgery from 1988 by Tomaso Vercellotti. It consists of an ultrasonic device able to cut mineralized bone tissue, without injuring the adjacent soft tissue. It also has several advantages when compared to conventional techniques with drills and saws, such as the production of a precise, clean and low bleed bone cut that shows positive biological results. In dental implants surgery, it has been used for maxillary sinus lifting, removal of bone blocks, distraction osteogenesis, lateralization of the inferior alveolar nerve, split crest of alveolar ridge and even for dental implants placement. The purpose of this paper is to discuss the use of piezosurgery in bone augmentation procedures used previously to dental implants placement. PMID:26966469
Madi, Marwa; Zakaria, Osama; Ichinose, Shizuko; Kasugai, Shohei
2016-02-01
The aim of this study was to compare the effect of ligature-induced periimplantitis on dental implants with and without hydroxyapatite (HA) coat. Thirty-two dental implants (3.3 mm wide, 13 mm long) with 4 surface treatments (8 implant/group) (M: machined, SA: sandblasted acid etched, S: sputter HA coat and P: plasma-sprayed HA coat) were inserted into canine mandibles. After 12 weeks, oral hygiene procedures were stopped and silk ligatures were placed around the implant abutments to allow plaque accumulation for the following 16 weeks. Implants with the surrounding tissues were retrieved and prepared for histological examination. Bone-to-implant contact (BIC) and implant surfaces were examined using scanning electron microscopy and energy dispersive x-ray spectroscopy. Histological observation revealed marginal bone loss and large inflammatory cell infiltrates in the periimplant soft tissue. Sputter HA implants showed the largest BIC (98.1%) and machined implant showed the smallest values (70.4%). After 28 weeks, thin sputter HA coat was almost completely dissolved, whereas plasma-sprayed HA coat showed complete thickness preservation. Thin sputter HA-coated implants showed more bone implant contact and less marginal bone loss than thick HA-coated implants under periimplantitis condition.
Advances in Materials for Recent Low-Profile Implantable Bioelectronics
Kim, Yun-Soung; Tillman, Bryan W.; Chun, Youngjae
2018-01-01
The rapid development of micro/nanofabrication technologies to engineer a variety of materials has enabled new types of bioelectronics for health monitoring and disease diagnostics. In this review, we summarize widely used electronic materials in recent low-profile implantable systems, including traditional metals and semiconductors, soft polymers, biodegradable metals, and organic materials. Silicon-based compounds have represented the traditional materials in medical devices, due to the fully established fabrication processes. Examples include miniaturized sensors for monitoring intraocular pressure and blood pressure, which are designed in an ultra-thin diaphragm to react with the applied pressure. These sensors are integrated into rigid circuits and multiple modules; this brings challenges regarding the fundamental material’s property mismatch with the targeted human tissues, which are intrinsically soft. Therefore, many polymeric materials have been investigated for hybrid integration with well-characterized functional materials such as silicon membranes and metal interconnects, which enable soft implantable bioelectronics. The most recent trend in implantable systems uses transient materials that naturally dissolve in body fluid after a programmed lifetime. Such biodegradable metallic materials are advantageous in the design of electronics due to their proven electrical properties. Collectively, this review delivers the development history of materials in implantable devices, while introducing new bioelectronics based on bioresorbable materials with multiple functionalities. PMID:29596359
Advances in Materials for Recent Low-Profile Implantable Bioelectronics.
Chen, Yanfei; Kim, Yun-Soung; Tillman, Bryan W; Yeo, Woon-Hong; Chun, Youngjae
2018-03-29
The rapid development of micro/nanofabrication technologies to engineer a variety of materials has enabled new types of bioelectronics for health monitoring and disease diagnostics. In this review, we summarize widely used electronic materials in recent low-profile implantable systems, including traditional metals and semiconductors, soft polymers, biodegradable metals, and organic materials. Silicon-based compounds have represented the traditional materials in medical devices, due to the fully established fabrication processes. Examples include miniaturized sensors for monitoring intraocular pressure and blood pressure, which are designed in an ultra-thin diaphragm to react with the applied pressure. These sensors are integrated into rigid circuits and multiple modules; this brings challenges regarding the fundamental material's property mismatch with the targeted human tissues, which are intrinsically soft. Therefore, many polymeric materials have been investigated for hybrid integration with well-characterized functional materials such as silicon membranes and metal interconnects, which enable soft implantable bioelectronics. The most recent trend in implantable systems uses transient materials that naturally dissolve in body fluid after a programmed lifetime. Such biodegradable metallic materials are advantageous in the design of electronics due to their proven electrical properties. Collectively, this review delivers the development history of materials in implantable devices, while introducing new bioelectronics based on bioresorbable materials with multiple functionalities.
Bone tissue reactions to biomimetic ion-substituted apatite surfaces on titanium implants.
Ballo, Ahmed M; Xia, Wei; Palmquist, Anders; Lindahl, Carl; Emanuelsson, Lena; Lausmaa, Jukka; Engqvist, Håkan; Thomsen, Peter
2012-07-07
The aim of this study was to evaluate the bone tissue response to strontium- and silicon-substituted apatite (Sr-HA and Si-HA) modified titanium (Ti) implants. Sr-HA, Si-HA and HA were grown on thermally oxidized Ti implants by a biomimetic process. Oxidized implants were used as controls. Surface properties, i.e. chemical composition, surface thickness, morphology/pore characteristics, crystal structure and roughness, were characterized with various analytical techniques. The implants were inserted in rat tibiae and block biopsies were prepared for histology, histomorphometry and scanning electron microscopy analysis. Histologically, new bone formed on all implant surfaces. The bone was deposited directly onto the Sr-HA and Si-HA implants without any intervening soft tissue. The statistical analysis showed significant higher amount of bone-implant contact (BIC) for the Si-doped HA modification (P = 0.030), whereas significant higher bone area (BA) for the Sr-doped HA modification (P = 0.034), when compared with the non-doped HA modification. The differences were most pronounced at the early time point. The healing time had a significant impact for both BA and BIC (P < 0.001). The present results show that biomimetically prepared Si-HA and Sr-HA on Ti implants provided bioactivity and promoted early bone formation.
Metallic orthopaedic implants and airport metal detectors.
Kamineni, S; Legge, S; Ware, H
2002-01-01
Airport security can detect in vivo metallic implants. We hypothesized that a soft tissue shield and fast transit through archway detectors would decrease implant detectability, whereas greater implant mass would increase detectability. Twelve patients with 8 orthopaedic implants in vivo and 60 trauma and arthroplasty implants in vitro were subjected to standard airport security measures at Stanstead Airport (British Airports Authority), including arch and standard and nonstandard hand-held detectors. Archway detectors failed to detect some implants; hand-held detectors detected almost all implants except an ankle arthroplasty. Positive archway detection was related to implant transit speed through the detection field. The implant mass consistently affected detection in stainless steel and titanium implants, and a 1-inch wax shield had no effect. Patients with metallic implants should prepare routinely with documentation of their implant before traveling through security ports.
The versatile subepithelial connective tissue graft: a literature update.
Karthikeyan, B V; Khanna, Divya; Chowdhary, Kamedh Yashawant; Prabhuji, M Lv
2016-01-01
Harmony between hard and soft tissue morphologies is essential for form, function, and a good esthetic outlook. Replacement grafts for correction of soft tissue defects around the teeth have become important to periodontal plastic and implant surgical procedures. Among a multitude of surgical techniques and graft materials reported in literature, the subepithelial connective tissue graft (SCTG) has gained wide popularity and acceptance. The purpose of this article is to acquaint clinicians with the current understanding of the versatile SCTG. Key factors associated with graft harvesting as well as applications, limitations, and complications of SCTGs are discussed. This connective tissue has shown excellent short- and long-term stability, is easily available, and is economical to use. The SCTG should be considered as an alternative in all periodontal reconstruction surgeries.
Regenerative Medicine for Periodontal and Peri-implant Diseases.
Larsson, L; Decker, A M; Nibali, L; Pilipchuk, S P; Berglundh, T; Giannobile, W V
2016-03-01
The balance between bone resorption and bone formation is vital for maintenance and regeneration of alveolar bone and supporting structures around teeth and dental implants. Tissue regeneration in the oral cavity is regulated by multiple cell types, signaling mechanisms, and matrix interactions. A goal for periodontal tissue engineering/regenerative medicine is to restore oral soft and hard tissues through cell, scaffold, and/or signaling approaches to functional and aesthetic oral tissues. Bony defects in the oral cavity can vary significantly, ranging from smaller intrabony lesions resulting from periodontal or peri-implant diseases to large osseous defects that extend through the jaws as a result of trauma, tumor resection, or congenital defects. The disparity in size and location of these alveolar defects is compounded further by patient-specific and environmental factors that contribute to the challenges in periodontal regeneration, peri-implant tissue regeneration, and alveolar ridge reconstruction. Efforts have been made over the last few decades to produce reliable and predictable methods to stimulate bone regeneration in alveolar bone defects. Tissue engineering/regenerative medicine provide new avenues to enhance tissue regeneration by introducing bioactive models or constructing patient-specific substitutes. This review presents an overview of therapies (e.g., protein, gene, and cell based) and biomaterials (e.g., resorbable, nonresorbable, and 3-dimensionally printed) used for alveolar bone engineering around teeth and implants and for implant site development, with emphasis on most recent findings and future directions. © International & American Associations for Dental Research 2015.
2010-01-01
Background Recent studies have shown the potential suitability of magnesium alloys as biodegradable implants. The aim of the present study was to compare the soft tissue biocompatibility of MgCa0.8 and commonly used surgical steel in vivo. Methods A biodegradable magnesium calcium alloy (MgCa0.8) and surgical steel (S316L), as a control, were investigated. Screws of identical geometrical conformation were implanted into the tibiae of 40 rabbits for a postoperative follow up of two, four, six and eight weeks. The tibialis cranialis muscle was in direct vicinity of the screw head and thus embedded in paraffin and histologically and immunohistochemically assessed. Haematoxylin and eosin staining was performed to identify macrophages, giant cells and heterophil granulocytes as well as the extent of tissue fibrosis and necrosis. Mouse anti-CD79α and rat anti-CD3 monoclonal primary antibodies were used for B- and T-lymphocyte detection. Evaluation of all sections was performed by applying a semi-quantitative score. Results Clinically, both implant materials were tolerated well. Histology revealed that a layer of fibrous tissue had formed between implant and overlying muscle in MgCa0.8 and S316L, which was demarcated by a layer of synoviocyte-like cells at its interface to the implant. In MgCa0.8 implants cavities were detected within the fibrous tissue, which were surrounded by the same kind of cell type. The thickness of the fibrous layer and the amount of tissue necrosis and cellular infiltrations gradually decreased in S316L. In contrast, a decrease could only be noted in the first weeks of implantation in MgCa0.8, whereas parameters were increasing again at the end of the observation period. B-lymphocytes were found more often in MgCa0.8 indicating humoral immunity and the presence of soluble antigens. Conversely, S316L displayed a higher quantity of T-lymphocytes. Conclusions Moderate inflammation was detected in both implant materials and resolved to a minimum during the first weeks indicating comparable biocompatibility for MgCa0.8 and S316L. Thus, the application of MgCa0.8 as biodegradable implant material seems conceivable. Since the inflammatory parameters were re-increasing at the end of the observation period in MgCa0.8 it is important to observe the development of inflammation over a longer time period in addition to the present study. PMID:20974008
Elastase-Sensitive Elastomeric Scaffolds with Variable Anisotropy for Soft Tissue Engineering
Guan, Jianjun; Fujimoto, Kazuro L.; Wagner, William R.
2010-01-01
Purpose To develop elastase-sensitive polyurethane scaffolds that would be applicable to the engineering of mechanically active soft tissues. Methods A polyurethane containing an elastase-sensitive peptide sequence was processed into scaffolds by thermally induced phase separation. Processing conditions were manipulated to alter scaffold properties and anisotropy. The scaffold’s mechanical properties, degradation, and cytocompatibility using muscle-derived stem cells were characterized. Scaffold in vivo degradation was evaluated by subcutaneous implantation. Results When heat transfer was multidirectional, scaffolds had randomly oriented pores. Imposition of a heat transfer gradient resulted in oriented pores. Both scaffolds were flexible and relatively strong with mechanical properties dependent upon fabrication conditions such as solvent type, polymer concentration and quenching temperature. Oriented scaffolds exhibited anisotropic mechanical properties with greater tensile strength in the orientation direction. These scaffolds also supported muscle-derived stem cell growth more effectively than random scaffolds. The scaffolds expressed over 40% weight loss after 56 days in elastase containing buffer. Elastase-sensitive scaffolds were complete degraded after 8 weeks subcutaneous implantation in rats, markedly faster than similar polyurethanes that did not contain the peptide sequence. Conclusion The elastase-sensitive polyurethane scaffolds showed promise for application in soft tissue engineering where controlling scaffold mechanical properties and pore architecture are desirable. PMID:18509596
Tissue-electronics interfaces: from implantable devices to engineered tissues
NASA Astrophysics Data System (ADS)
Feiner, Ron; Dvir, Tal
2018-01-01
Biomedical electronic devices are interfaced with the human body to extract precise medical data and to interfere with tissue function by providing electrical stimuli. In this Review, we outline physiologically and pathologically relevant tissue properties and processes that are important for designing implantable electronic devices. We summarize design principles for flexible and stretchable electronics that adapt to the mechanics of soft tissues, such as those including conducting polymers, liquid metal alloys, metallic buckling and meandering architectures. We further discuss technologies for inserting devices into the body in a minimally invasive manner and for eliminating them without further intervention. Finally, we introduce the concept of integrating electronic devices with biomaterials and cells, and we envision how such technologies may lead to the development of bionic organs for regenerative medicine.
Zuhr, Otto; Rebele, Stephan F; Cheung, Stefani L; Hürzeler, Markus B
2018-06-01
Diverse clinical advancements, together with some relevant technical innovations, have led to an increase in popularity of tunneling flap procedures in plastic periodontal and implant surgery in the recent past. This trend is further promoted by the fact that these techniques have lately been introduced to a considerably expanded range of indications. While originally described for the treatment of gingival recession-type defects, tunneling flap procedures may now be applied successfully in a variety of clinical situations in which augmentation of the soft tissues is indicated in the esthetic zone. Potential clinical scenarios include surgical thickening of thin buccal gingiva or peri-implant mucosa, alveolar ridge/socket preservation and implant second-stage surgery, as well as soft-tissue ridge augmentation or pontic site development. In this way, tunneling flap procedures developed from a technique, originally merely intended for surgical root coverage, into a capacious surgical conception in plastic periodontal and implant surgery. The purpose of this article is to provide a comprehensive overview on tunneling flap procedures, to introduce the successive development of the approach along with underlying ideas on surgical wound healing and to present contemporary clinical scenarios in step-by-step photograph-illustrated sequences, which aim to provide clinicians with guidance to help them integrate tunneling flap procedures into their daily clinical routine. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Zygoma Implant-Supported Prosthetic Rehabilitation of a Patient After Bilateral Maxillectomy.
Celakil, Tamer; Ayvalioglu, Demet Cagil; Sancakli, Erkan; Atalay, Belir; Doganay, Ozge; Kayhan, Kivanc Bektas
2015-10-01
Maxillectomy defects may vary from localized to extensive soft and hard tissue loss. In addition to physical and psychologic damages, functional and aesthetic aspects must be restored. This clinical report describes the rehabilitation of a patient with a zygoma implant-supported obturator prosthesis caused by a subtotal bilateral maxillectomy due to a squamous oral cell carcinoma. Prosthetic rehabilitation of this patient was performed after zygoma implant surgery. A maxillary obturator prosthesis supported by 2 osseointegrated zygoma implants was fabricated. Despite limited mouth opening and anatomic deficiencies, the patient's aesthetic and functional demands were fulfilled.
Current concepts in the use of lasers in periodontal and implant dentistry
Romanos, Georgios
2015-01-01
Lasers have various periodontal applications including calculus removal (Er: YAG, Er, Cr: YSGG lasers); soft tissue excision, incision and ablation; decontamination of root and implant surfaces; biostimulation; bacteria reduction; and osseous surgery. This paper reviews some of the major opportunities for using lasers in periodontal and implant specialty practices. The literature relating to the use of lasers for removal of the pocket epithelium, root conditioning, bacterial reduction and decontamination of infected implant surfaces is discussed, and a summary of the advantages and disadvantages of using lasers for periodontal treatment is provided. PMID:26644712
Ricciardi, Benjamin F; Nocon, Allina A; Jerabek, Seth A; Wilner, Gabrielle; Kaplowitz, Elianna; Goldring, Steven R; Purdue, P Edward; Perino, Giorgio
2016-01-01
Adverse local tissue reaction (ALTR), characterized by a heterogeneous cellular inflammatory infiltrate and the presence of corrosion products in the periprosthetic soft tissues, has been recognized as a mechanism of failure in total hip replacement (THA). Different histological subtypes may have unique needs for longitudinal clinical follow-up and complication rates after revision arthroplasty. The purpose of this study was to describe the histological patterns observed in the periprosthetic tissue of failed THA in three different implant classes due to ALTR and their association with clinical features of implant failure. Consecutive patients presenting with ALTR from three major hip implant classes (N = 285 cases) were identified from our prospective Osteolysis Tissue Database and Repository. Clinical characteristics including age, sex, BMI, length of implantation, and serum metal ion levels were recorded. Retrieved synovial tissue morphology was graded using light microscopy. Clinical characteristics and features of synovial tissue analysis were compared between the three implant classes. Histological patterns of ALTR identified from our observations and the literature were used to classify each case. The association between implant class and histological patterns was compared. Our histological analysis demonstrates that ALTR encompasses three main histological patterns: 1) macrophage predominant, 2) mixed lymphocytic and macrophagic with or without features of associated with hypersensitivity/allergy or response to particle toxicity (eosinophils/mast cells and/or lymphocytic germinal centers), and 3) predominant sarcoid-like granulomas. Implant classification was associated with histological pattern of failure, and the macrophagic predominant pattern was more common in implants with metal-on-metal bearing surfaces (MoM HRA and MoM LHTHA groups). Duration of implantation and composition of periprosthetic cellular infiltrates was significantly different amongst the three implant types examined suggesting that histopathological features of ALTR may explain the variability of clinical implant performance in these cases. ALTR encompasses a diverse range of histological patterns, which are reflective of both the implant configuration independent of manufacturer and clinical features such as duration of implantation. The macrophagic predominant pattern and its mechanism of implant failure represent an important subgroup of ALTR which could become more prominent with increased length of implantation.
NASA Astrophysics Data System (ADS)
Muller, Ludovic; Baldwin, Kathrine; Barbacci, Damon C.; Jackson, Shelley N.; Roux, Aurélie; Balaban, Carey D.; Brinson, Bruce E.; McCully, Michael I.; Lewis, Ernest K.; Schultz, J. Albert; Woods, Amina S.
2017-08-01
Mass spectrometry imaging (MSI) of tissue implanted with silver nanoparticulate (AgNP) matrix generates reproducible imaging of lipids in rodent models of disease and injury. Gas-phase production and acceleration of size-selected 8 nm AgNP is followed by controlled ion beam rastering and soft landing implantation of 500 eV AgNP into tissue. Focused 337 nm laser desorption produces high quality images for most lipid classes in rat brain tissue (in positive mode: galactoceramides, diacylglycerols, ceramides, phosphatidylcholines, cholesteryl ester, and cholesterol, and in negative ion mode: phosphatidylethanolamides, sulfatides, phosphatidylinositol, and sphingomyelins). Image reproducibility in serial sections of brain tissue is achieved within <10% tolerance by selecting argentated instead of alkali cationized ions. The imaging of brain tissues spotted with pure standards was used to demonstrate that Ag cationized ceramide and diacylglycerol ions are from intact, endogenous species. In contrast, almost all Ag cationized fatty acid ions are a result of fragmentations of numerous lipid types having the fatty acid as a subunit. Almost no argentated intact fatty acid ions come from the pure fatty acid standard on tissue.
NASA Astrophysics Data System (ADS)
Lee, Heui Chang; Ejserholm, Fredrik; Gaire, Janak; Currlin, Seth; Schouenborg, Jens; Wallman, Lars; Bengtsson, Martin; Park, Kinam; Otto, Kevin J.
2017-06-01
Objective. Flexible neural probes are hypothesized to reduce the chronic foreign body response (FBR) mainly by reducing the strain-stress caused by an interplay between the tethered probe and the brain’s micromotion. However, a large discrepancy of Young’s modulus still exists (3-6 orders of magnitude) between the flexible probes and the brain tissue. This raises the question of whether we need to bridge this gap; would increasing the probe flexibility proportionally reduce the FBR? Approach. Using novel off-stoichiometry thiol-enes-epoxy (OSTE+) polymer probes developed in our previous work, we quantitatively evaluated the FBR to four types of probes with different softness: silicon (~150 GPa), polyimide (1.5 GPa), OSTE+Hard (300 MPa), and OSTE+Soft (6 MPa). Main results. We observed a significant reduction in the fluorescence intensity of biomarkers for activated microglia/macrophages and blood-brain barrier (BBB) leakiness around the three soft polymer probes compared to the silicon probe, both at 4 weeks and 8 weeks post-implantation. However, we did not observe any consistent differences in the biomarkers among the polymer probes. Significance. The results suggest that the mechanical compliance of neural probes can mediate the degree of FBR, but its impact diminishes after a hypothetical threshold level. This infers that resolving the mechanical mismatch alone has a limited effect on improving the lifetime of neural implants.
Zhang, Jing; Tian, Jiabin; Ta, Na; Huang, Xinsheng; Rao, Zhushi
2016-08-01
Finite element method was employed in this study to analyze the change in performance of implantable hearing devices due to the consideration of soft tissues' viscoelasticity. An integrated finite element model of human ear including the external ear, middle ear and inner ear was first developed via reverse engineering and analyzed by acoustic-structure-fluid coupling. Viscoelastic properties of soft tissues in the middle ear were taken into consideration in this model. The model-derived dynamic responses including middle ear and cochlea functions showed a better agreement with experimental data at high frequencies above 3000 Hz than the Rayleigh-type damping. On this basis, a coupled finite element model consisting of the human ear and a piezoelectric actuator attached to the long process of incus was further constructed. Based on the electromechanical coupling analysis, equivalent sound pressure and power consumption of the actuator corresponding to viscoelasticity and Rayleigh damping were calculated using this model. The analytical results showed that the implant performance of the actuator evaluated using a finite element model considering viscoelastic properties gives a lower output above about 3 kHz than does Rayleigh damping model. Finite element model considering viscoelastic properties was more accurate to numerically evaluate implantable hearing devices. © IMechE 2016.
Tiihonen, R; Honkanen, P B; Belt, E A; Ikävalko, M; Skyttä, E T
2012-01-01
Revision arthroplasty of metacarpophalangeal (MCP) joints in chronic inflammatory arthritis patients after silicone implants is challenging due of severe bone loss and soft tissue deficiencies. The aim of this study was to evaluate the outcome of revision MCP arthroplasty using poly-L/D-lactic acid 96:4 (PLDLA) interposition implant and morcelised allograft or autograft bone packing in patients with failed MCP arthroplasties and severe osteolysis. The study group consisted of 15 patients (15 hands and 36 joints) at a mean follow-up of seven years (range 5-10 years). The radiographs were reviewed for osteolysis and incorporation of the grafted bone. The clinical assessments included active range of motion, evaluation of pain, subjective outcome and assessment of grip power. PLDLA interposition arthroplasty combined with bone packing provided satisfactory pain relief, but function was limited. Radiographic analysis showed complete incorporation of the grafted bone to the diaphyseal portion of the host metacarpal and phalangeal bones in 30 of the 36 joints. All the patients had very limited grip strength, both on the operated and non-operated side. Due to soft tissue deficiencies long-term function and alignment problems can not be resolved with PLDLA interposition implant.
Multilayer cell-seeded polymer nanofiber constructs for soft-tissue reconstruction.
Barker, Daniel A; Bowers, Daniel T; Hughley, Brian; Chance, Elizabeth W; Klembczyk, Kevin J; Brayman, Kenneth L; Park, Stephen S; Botchwey, Edward A
2013-09-01
Cell seeding throughout the thickness of a nanofiber construct allows for patient-specific implant alternatives with long-lasting effects, earlier integration, and reduced inflammation when compared with traditional implants. Cell seeding may improve implant integration with host tissue; however, the effect of cell seeding on thick nanofiber constructs has not been studied. To use a novel cell-preseeded nanofiber tissue engineering technique to create a 3-dimensional biocompatible implant alternative to decellularized extracellular matrix. Animal study with mammalian cell culture to study tissue engineered scaffolds. Academic research laboratory. Thirty-six Sprague-Dawley rats. The rats each received 4 implant types. The grafts included rat primary (enhanced green fluorescent protein-positive [eGFP+]) fibroblast-seeded polycaprolactone (PCL)/collagen nanofiber scaffold, PCL/collagen cell-free nanofiber scaffold, acellular human cadaveric dermis (AlloDerm), and acellular porcine dermis (ENDURAGen). Rats were monitored postoperatively and received enrofloxacin in the drinking water for 4 days prophylactically and buprenorphine (0.2-0.5 mg/kg administered subcutaneously twice a day postoperatively for pain for 48 hours). The viability of NIH/3T3 fibroblasts cultured on PCL electrospun nanofibers was evaluated using fluorescence microscopy. Soft-tissue remodeling was examined histologically and with novel ex vivo volume determinations of implants using micro-computed tomography of cell-seeded implants relative to nanofibers without cells and commonly used dermal grafts of porcine and human origin (ENDURAGen and AlloDerm, respectively). The fate and distribution of eGFP+ seeded donor fibroblasts were assessed using immunohistochemistry. Fibroblasts migrated across nanofiber layers within 12 hours and remained viable on a single layer for up to 14 days. Scanning electron microscopy confirmed a nanoscale structure with a mean (SD) diameter of 158 (72) nm. Low extrusion rates demonstrated the excellent biocompatibility in vivo. Histological examination of the scaffolds demonstrated minimal inflammation. Cell seeding encouraged rapid vascularization of the nanofiber implants. Cells of donor origin (eGFP+) declined with the duration of implantation. Implant volume was not significantly affected for up to 8 weeks by the preseeding of cells (P > .05). Polymer nanofiber-based scaffolds mimic natural extracellular matrix. Preseeding the nanofiber construct with cells improved vascularization without notable effects on volume. An effect of cell preseeding on scaffold vascularization was evident beyond the presence of preseeded cells. This 3-dimensional, multilayer method of cell seeding throughout a 1-mm-thick construct is simple and feasible for clinical application. Further development of this technique may affect the clinical practice of facial plastic and reconstructive surgeons.
Canullo, Luigi; Dehner, Jan Friedrich; Penarrocha, David; Checchi, Vittorio; Mazzoni, Annalisa; Breschi, Lorenzo
2016-01-01
The aim of this preliminary prospective RCT was to histologically evaluate peri-implant soft tissues around titanium abutments treated using different cleaning methods. Sixteen patients were randomized into three groups: laboratory customized abutments underwent Plasma of Argon treatment (Plasma Group), laboratory customized abutments underwent cleaning by steam (Steam Group), and abutments were used as they came from industry (Control Group). Seven days after the second surgery, soft tissues around abutments were harvested. Samples were histologically analyzed. Soft tissues surrounding Plasma Group abutments predominantly showed diffuse chronic infiltrate, almost no acute infiltrate, with presence of few polymorphonuclear neutrophil granulocytes, and a diffuse presence of collagenization bands. Similarly, in Steam Group, the histological analysis showed a high variability of inflammatory expression factors. Tissues harvested from Control Group showed presence of few neutrophil granulocytes, moderate presence of lymphocytes, and diffuse collagenization bands in some sections, while they showed absence of acute infiltrate in 40% of sections. However, no statistical difference was found among the tested groups for each parameter (p > 0.05). Within the limit of the present study, results showed no statistically significant difference concerning inflammation and healing tendency between test and control groups.
Manoukian, Ohan S; Matta, Rita; Letendre, Justin; Collins, Paige; Mazzocca, Augustus D; Kumbar, Sangamesh G
2017-01-01
Electrospinning has emerged as a simple, elegant, and scalable technique that can be used to fabricate polymeric nanofibers. Pure polymers as well as blends and composites of both natural and synthetic ones have been successfully electrospun into nanofiber matrices for many biomedical applications. Tissue-engineered medical implants, such as polymeric nanofiber scaffolds, are potential alternatives to autografts and allografts, which are short in supply and carry risks of disease transmission. These scaffolds have been used to engineer various soft tissues, including connective tissues, such as skin, ligament, and tendon, as well as nonconnective ones, such as vascular, muscle, and neural tissue. Electrospun nanofiber matrices show morphological similarities to the natural extracellular matrix (ECM), characterized by ultrafine continuous fibers, high surface-to-volume ratios, high porosities, and variable pore-size distributions. The physiochemical properties of nanofiber matrices can be controlled by manipulating electrospinning parameters so that they meet the requirements of a specific application.Nanostructured implants show improved biological performance over bulk materials in aspects of cellular infiltration and in vivo integration, taking advantage of unique quantum, physical, and atomic properties. Furthermore, the topographies of such scaffolds has been shown to dictate cellular attachment, migration, proliferation, and differentiation, which are critical in engineering complex functional tissues with improved biocompatibility and functional performance. This chapter discusses the use of the electrospinning technique in the fabrication of polymer nanofiber scaffolds utilized for the regeneration of soft tissues. Selected scaffolds will be seeded with human mesenchymal stem cells (hMSCs), imaged using scanning electron and confocal microscopy, and then evaluated for their mechanical properties as well as their abilities to promote cell adhesion, proliferation , migration, and differentiation.
Jebahi, S; Oudadesse, H; Jardak, N; Khayat, I; Keskes, H; Khabir, A; Rebai, T; El Feki, H; El Feki, A
2013-07-01
New synthetic biomaterials are constantly being developed for wound repair and regeneration. Bioactive glasses (BG) containing strontium have shown successful applications in tissue engineering account of their biocompatibility and the positive biological effects after implantation. This study aimed to assess whether BG-Sr was accepted by the host tissue and to characterize oxidative stress biomarker and antioxidant enzyme profiles during muscle and skin healing. Wistar rats were divided into five groups (six animals per group): the group (I) was used as negative control (T), after ovariectomy, groups II, III, IV and V were used respectively as positive control (OVX), implanted tissue with BG (OVX-BG), BG-Sr (OVX-BG-Sr) and presented empty defects (OVX-NI). Soft tissues surrounding biomaterials were used to estimate superoxide dismutase (SOD), catalase (CAT), glutathione peroxidase (GPx) and malondialdehyde (MDA) concentration. Our results show that 60 days after operation, treatment of rats with BG-Sr significantly increased MDA concentration and caused an increase of SOD, CAT and GPx activities in both skin and muscular tissues. BG-Sr revealed maturation of myotubes followed a normal appearance of muscle regenerated with high density and mature capillary vessels. High wound recovery with complete re-epithelialization and regeneration of skin was observed. The results demonstrate that the protective action against reactive oxygen species (ROS) was clearly observed in soft tissue surrounding BG-Sr. Moreover, the potential use of BG-Sr rapidly restores the wound skin and muscle structural and functional properties. The BG advantages such as ion release might make BG-Sr an effective biomaterial choice for antioxidative activity. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Yunus, Norsiah; Saub, Roslan; Taiyeb Ali, Tara Bai; Salleh, Nosizana Mohd; Baig, Mirza Rustum
2014-01-01
The purpose of this study was to evaluate and compare Oral Health-Related Quality of Life (OHRQoL), denture satisfaction, and masticatory performance in edentulous patients provided with mandibular implant-supported overdentures (ISODs) retained with telescopic attachments and those of conventional complete dentures (CCDs). Peri-implant soft tissue changes were also evaluated at various intervals during a 1-year observation period. Participating patients received new CCDs and later received two mandibular interforaminal implants and had their mandibular CCDs converted into ISODs with telescopic attachments. Questionnaires were used to assess OHRQoL (Shortened Oral Health Impact Profile-14, Malaysian version) and denture satisfaction at different stages of treatment with CCDs and ISODs. Objective masticatory performance with the CCDs and ISODs was recorded with a mixing ability test. Evaluations were carried out at 3 months with the new CCDs, 3 months after mandibular ISOD provision, and 1 year after receiving the ISOD. Peri-implant parameters were additionally assessed at specific intervals during the treatment period. The data obtained were statistically analyzed and compared. In the 17 patients who completed the protocol, significant improvements were observed in OHRQoL and patient satisfaction when CCDs were modified to ISODs, after 3 months, and at 1 year. Significantly better mixing ability with the ISOD was noted, with the highest values observed at 1 year. Statistically insignificant differences were observed for all the peri-implant parameters, except for gingival recession, for which significant changes were observed 6 months after ISOD delivery (values had stabilized by 1 year). Telescopic crown attachment-retained mandibular ISODs improved OHRQoL, dental prosthesis satisfaction, and masticatory performance compared to CCDs. Peri-implant soft tissue response and implant stability were found to be favorable after 1 year.
Plastic efficiency of different implants used for repair of soft and bone tissue defects.
Iriyanov, Yu M; Chernov, V F; Radchenko, S A; Chernov, A V
2013-08-01
The results of clinical and experimental morphological studies of regenerates forming after replacement of large defects of the abdominal wall and tibia with implants from different materials (polytetrafluoroethylene, reperene, prolene, titanium, and titanium nickelide) are analyzed. Study of the regenerate histology and fibroarchitectonics has shown good prospects of mesh constructions from titanium nickelide for effective surgical repair of these defects. The use of this implant seems to be theoretically well-based and promising, particularly under conditions of suppurative infection and low individual reparative regenerative potential.
Lasers use in dental implantology.
Romanos, Georgios E; Gupta, Bhumija; Yunker, Mike; Romanos, Enisa Begic; Malmstrom, Hans
2013-06-01
The purpose of this literature review was to evaluate the present use of different laser systems in implant dentistry. A literature search of MEDLINE-PubMed for articles published, describing the use of lasers in implant dentistry, was performed and articles were critically reviewed by the investigators to determine the strength of evidence. The literature review reveals a limited number of randomized clinical trials with regard to laser use in dentistry. Although many case studies indicate extensive use of lasers and promising results in dental implantology, lasers may be used for uncovering submerged implants atraumatically to prevent crestal bone loss, recontouring periimplant soft tissues and sculpting emergence profile for prosthetic components, raising surgical flaps, osseous recontouring, and creating parabolic tissue architecture. Additionally, bone harvesting of block grafts, window preparation in sinus lift procedures, ridge splitting, and debridement of extraction sockets for immediate implant placement were described. Aside from the many benefits associated with the use of lasers in implant-related procedures, there are also risks to consider from the laser irradiation on the implant surface and the periimplant tissues. Therefore, an appropriate training on laser use is mandatory to increase the clinical outcome and to control the potential of complications.
Torres-Coy, J A; Rodríguez-Castillo, B A; Pérez-Alfonzo, R; DE Waard, J H
2016-04-01
Outbreaks of soft tissue or skin infection due to non-tuberculous mycobacteria are reported frequently in scientific journals but in general the infection source in these outbreaks remains unknown. In Venezuela, in two distinct outbreaks, one after breast augmentation surgery and another after hydrolipoclasy therapy, 16 patients contracted a soft tissue infection due to Mycobacterium abscessus subsp. abscessus. Searching for the possible environmental infection sources in these outbreaks, initially the tap water (in the hydrolipoclasy therapy outbreak) and a surgical skin marker (in the breast implant surgery outbreak), were identified as the infection sources. Molecular typing of the strains with a variable number tandem repeat typing assay confirmed the tap water as the infection source but the molecular typing technique excluded the skin marker. We discuss the results and make a call for the implementation of stringent hygiene and disinfection guidelines for cosmetic procedures in Venezuela.
Current surgical strategies for total arthroplasty in valgus knee
Nikolopoulos, Dimitrios; Michos, Ioannis; Safos, George; Safos, Petros
2015-01-01
The majority of orthopaedic surgeons even currently agree that primary total arthroplasty in valgus knees with a deformity of more than ten degrees may prove challenging. The unique sets of bone and soft tissue abnormalities that must be addressed at the time of the operation make accurate axis restoration, component orientation and joint stability attainment a difficult task. Understanding the specific pathologic anatomic changes associated with the valgus knee is a prerequisite so as to select the proper surgical method, to optimize component position and restore soft-tissue balance. The purpose of this article is to review the valgus knee anatomical variations, to assess the best pre-operative planning and to evaluate how to choose the grade of constraint of the implant. It will also be underlying the up-to-date main approaches and surgical techniques be proposed in the English literature both for bone cuts and soft tissue management of valgus knees. PMID:26191494
Brown, James E; Qiang, Rui; Stadnik, Paul J; Stotts, Larry J; Von Arx, Jeffrey A
2017-01-01
Magnetic resonance imaging (MRI) is the preferred modality for soft tissue imaging because of its nonionizing radiation and lack of contrast agent. Due to interactions between the MR system and active implantable medical devices (AIMDs), patients with implants such as pacemakers are generally denied access to MRI, which presents a detriment to that population. It has been estimated that 50-75% of patients with a cardiac device were denied access to MRI scanning and, moreover, that 17% of pacemaker patients need an MRI within 12 months of implantation [1]. In recent years, AIMD manufacturers, such as Biotronik, have assessed the conditional safety of devices in MRI.
Kaner, Doğan; Zhao, Han; Arnold, Wolfgang; Terheyden, Hendrik; Friedmann, Anton
2017-06-01
Soft tissue (ST) dehiscence with graft exposure is a frequent complication of vertical augmentation. Flap dehiscence is caused by failure to achieve tension-free primary wound closure and by the impairment of flap microcirculation due to surgical trauma. Soft tissue expansion (STE) increases ST quality and quantity prior to reconstructive surgery. We hypothesized that flap preconditioning using STE would reduce the incidence of ST complications after bone augmentation and that optimized ST healing would improve the outcome of bone regeneration. Self-filling tissue expanders were implanted in mandibular bone defects in ten beagle dogs. After expansion, alloplastic scaffolds were placed for vertical bone augmentation in STE sites and in control sites without STE pre-treatment. ST flap microcirculation was analysed using laser Doppler flowmetry. The incidence of graft exposures was evaluated after 2 weeks. Bone formation was assessed after 2 months, using histomorphometry and immunohistochemistry. Test sites showed significantly less impairment of perfusion and faster recovery of microcirculation after bone augmentation. Furthermore, no flap dehiscences occurred in STE sites. Bone regeneration was found in both groups; however, significantly greater formation of new bone was detected in test sites with preceding STE. Preconditioning using STE improved ST healing and bone formation after vertical augmentation. The combination of STE and the subsequent placement of alloplastic scaffolds may facilitate the reconstruction of severe bone defects. © 2016 The Authors. Clinical Oral Implants Research Published by John Wiley & Sons Ltd.
[Role of endo-osseus implant in odonto-oral rehabilitation].
Vanhakendover, S
2003-01-01
Dental implants have critically changed the restorative procedures available to edentulous patients. Biocompatible materials, precise surgical techniques and improved instrumentation give well trained practicioners various opportunities to achieve successful treatments. The necessity of combining full expertise in surgery and rational prosthetic planning with comprehensive occlusal management is emphasized. Recent advances in periodontal treatment of osseous and soft tissue defects, new grafting techniques and surgical approaches have dramatically enlarged the scope of oral implantology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guilmette, Ray A.; Hahn, Fletcher F.; Durbin, P. W.
A number of U. S. veterans of the Persian Gulf War were wounded with depleted uranium (DU) metal fragments as a result of 'friendly fire' incidents, in which Abrams tanks and Bradley fighting vehicles were struck by DU anti-armor munitions. Some of the crew members who survived were left with multiple small fragments of DU in their muscles and soft tissues. The number, size and location of the fragments made them inoperable in general, and therefore subject to long-term retention. Because there was inadequate data to predict the potential carcinogenicity of DU fragments in soft tissues, Hahn et al. (2003)more » conducted a lifespan cancer study in rats. As part of that study, a number of rats were maintained to study the biokinetics and dosimetry of DU implanted intramuscularly in male Wistar rats. Typically, four metal fragments, either as cylindrical pellets or square wafers were implanted into the biceps femoris muscles of the rats. Urine samples were collected periodically during their lifespans, and DU was analyzed in kidneys and eviscerated carcass (minus the implant sites) at death. The daily DU urinary excretion rate increased steeply during the first 30 d after implantation peaking at about 90 d at 3-10 x 10{sup -3}%/d. During the first 150 d, the average excretion rate was 2.4 x 10{sup -3}%/d, decreasing thereafter to about 1 x 10{sup -3}%/d. Serial radiographs were made of the wound sites to monitor gross morphologic changes in the DU implant and the surrounding tissue. As early as 1 w after implantation, radiographs showed the presence of surface corrosion and small, dense bodies near the original implant, presumably DU. This corrosion from the surface of the implant continued with time, but did not result in an increasing amount of DU reaching the blood and urine after the first 3 mo. During this 3-mo period, connective tissue capsules formed around the implants, and are hypothesized to have reduced the access of DU to tissue fluids by limiting the diffusion rate of dissolved chemical forms of DU. Using a model of wound-site retention being developed by a committee of the U.S. National Council of Radiation Protection and Measurements (NCRP), it was found that the average retention of DU in the wound site could be described by a two-component exponential function in which 0.5% of the DU was retained with a half time of 80 d and the remainder with a half time of about 300 y.« less
Code of Federal Regulations, 2014 CFR
2014-04-01
... FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS IMPLANTATION OR INJECTABLE DOSAGE FORM NEW ANIMAL DRUGS § 522.56 Amikacin. (a... Escherichia coli and Proteus spp. and skin and soft tissue infections caused by susceptible strains of...
Code of Federal Regulations, 2012 CFR
2012-04-01
... FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS IMPLANTATION OR INJECTABLE DOSAGE FORM NEW ANIMAL DRUGS § 522.56 Amikacin. (a... of Escherichia coli and Proteus spp. and skin and soft tissue infections caused by susceptible...
21 CFR 522.90b - Ampicillin trihydrate.
Code of Federal Regulations, 2013 CFR
2013-04-01
... Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS IMPLANTATION OR INJECTABLE DOSAGE FORM NEW ANIMAL DRUGS § 522.90b..., gastrointestinal infections, skin infections, soft tissue infections, and postsurgical infections. (iii...
21 CFR 522.90b - Ampicillin trihydrate.
Code of Federal Regulations, 2012 CFR
2012-04-01
... Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS IMPLANTATION OR INJECTABLE DOSAGE FORM NEW ANIMAL DRUGS § 522.90b..., gastrointestinal infections, skin infections, soft tissue infections, and postsurgical infections. (iii...
Code of Federal Regulations, 2013 CFR
2013-04-01
... FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS IMPLANTATION OR INJECTABLE DOSAGE FORM NEW ANIMAL DRUGS § 522.56 Amikacin. (a... of Escherichia coli and Proteus spp. and skin and soft tissue infections caused by susceptible...
Leonida, Alessandro; Todeschini, Giovanni; Lomartire, Giovanni; Cinci, Lorenzo; Pieri, Laura
2016-11-01
To histologically assess the effectiveness of a socket-preservation technique using enzyme-treated equine bone granules as a bone-graft material in combination with an equine collagen matrix as a scaffold for soft-tissue regeneration. Enzyme-treated equine bone granules and equine collagen matrix recently have been developed to help overcome alveolar bone deficiencies that develop in the wake of edentulism. The patient had one mandibular molar extracted and the socket grafted with equine bone granules. The graft was covered with the equine collagen matrix, placed in a double layer. No flap was prepared, and the gingival margins were stabilized with a single stitch, leaving the matrix partially exposed and the site to heal by secondary intention. The adjacent molar was extracted 1 month later, and that socket was left to heal by secondary intention without any further treatment. Three months after each surgery, an implant was placed and a biopsy was collected. The two biopsies underwent histological processing and qualitative evaluation. Histomorphometric analysis was also performed to calculate the percentage of newly formed bone (NFB) in the two cores. Healing at both sites was uneventful, and no inflammation or other adverse reactions were observed in the samples. Soft-tissue healing by secondary intention appeared to occur faster at the grafted site. The corresponding core showed a marked separation between soft and hard tissue that was not observed in the core from the nongrafted site, where soft-tissue hypertrophy could be observed. Newly formed bone at the grafted and nongrafted sites was not significantly different (27.2 ± 7.1 and 29.4 ± 6.2% respectively, p = 0.45). The surgical technique employed in this case appeared to facilitate postextraction soft-tissue healing by second intention and simplify soft-tissue management. Using a collagen-based matrix to cover a postextraction grafted site may facilitate second intention soft-tissue healing and proper soft-tissue growth.
Olszewski, Waldemar L; Zaleska, Marzanna
2015-10-01
Lymphedema of limbs is caused by partial or total obstruction of lymphatic collectors as a consequence of skin and deep soft tissue inflammation, trauma of soft tissues and bones, lymphadenectomy, and irradiation in cancer therapy. According to the statistics of the World Health Organization, around 300 million people are affected by pathologic edema of limbs. Effective treatment of such large cohorts has been a challenge for centuries. However, none of the conservative and surgical methods applied so far proved to restore the shape and function of limbs to normal conditions. Actually, physiotherapy is the therapy of choice as a main modality or supplementary to surgical procedures divided into two groups: the bridging drainage and excisional techniques. The microsurgical operations can be performed if some parts of the peripheral collecting lymphatics remain patent and partially drain edematous regions. However, in advanced cases of lymphedema, all main lymphatics are obstructed and tissue fluid accumulates in the interstitial spaces, spontaneously forming "blind channels" or "lakes." The only solution would be to create artificial pathways for edema fluid flow away to the nonobstructed regions where absorption of fluid can take place. The aim of this study was to form artificial pathways for edema fluid flow by subcutaneous implantation of silicone tubes placed along the limb from the lower leg to the lumbar or hypogastric region. In a group of 20 patients with obstructive lymphedema of the lower limbs that developed after lymphadenectomy and irradiation of the pelvis because of uterine cancer with unsuccessful conservative therapy, implantation was done, followed by external compression as intermittent pneumatic compression and elastic support of tissues. Postoperative circumference measurements, lymphoscintigraphy, and ultrasonography of tissues were carried out during 2 years of follow-up. There was a fast decrease of calf circumference since the day of implantation during weeks by a mean 3% with stabilization afterward. Patency of tubes and accumulation of fluid around them were seen on ultrasonography and lymphoscintigraphy in all cases. No tissue cellular reaction to silicone tubes was noted. The simplicity of the surgical procedure, decrease of limb edema, and lack of tissue reaction to the implant make the method worth applying in advanced stages of lymphedema with large volumes of accumulated tissue edema fluid. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Risk indicators related to peri-implant disease: an observational retrospective cohort study
2016-01-01
Purpose The aim of the present study was to retrospectively investigate the influence of potential risk indicators on the development of peri-implant disease. Methods Overall, 103 patients referred for implant treatment from 2000 to 2012 were randomly enrolled. The study sample consisted of 421 conventional-length (>6 mm) non-turned titanium implants that were evaluated clinically and radiographically according to pre-established clinical and patient-related parameters by a single investigator. A non-parametric Mann-Whitney U test or Kruskal-Wallis rank test and a logistic regression model were used for the statistical analysis of the recorded data at the implant level. Results The diagnosis of peri-implant mucositis and peri-implantitis was made for 173 (41.1%) and 19 (4.5%) implants, respectively. Age (≥65 years), patient adherence (professional hygiene recalls <2/year) and the presence of plaque were associated with higher peri-implant probing-depth values and bleeding-on-probing scores. The logistic regression analysis indicated that age (P=0.001), patient adherence (P=0.03), the absence of keratinized tissue (P=0.03), implants placed in pristine bone (P=0.04), and the presence of peri-implant soft-tissue recession (P=0.000) were strongly associated with the event of peri-implantitis. Conclusions Within the limitations of this study, patients aged ≥65 years and non-adherent subjects were more prone to develop peri-implant disease. Therefore, early diagnosis and a systematic maintenance-care program are essential for maintaining peri-implant tissue health, especially in older patients. PMID:27588216
Reich, Waldemar; Exner, Anika; Winter, Eileen; Al-Nawas, Bilal; Eckert, Alexander Walter
2017-01-01
The reconstruction of extended defects of the concha poses a complex challenge for plastic surgeons. In cases of subtotal ablation, an alternative method designed especially for elderly oncological patients consists of epithetic rehabilitation. However, inserting an implant-retained concha epithesis proves challenging in patients with antecedents of deep resections involving the mastoid process. In the present case study, we report on the long-term treatment course (2009–2017) of a 79-year-old male patient suffering from a recurrent basal cell carcinoma of the retroauricular region. Following tumor resection, along with lateral mastoidectomy, reconstruction, and adjuvant radiotherapy, functional and esthetic deficits primarily due to peripheral facial nerve palsy were successfully managed using a multistep procedure. The procedure was completed by inserting an implant-retained concha epithesis, resulting in improved quality of life. Due to prior lateral mastoidectomy, ultra-short implants (4 mm) were inserted, partially at atypical positions. For maintaining healthy periimplant soft tissue, aftercare comprised cold plasma treatment. This oncologic case demonstrates the therapeutic necessity of using a broad spectrum of reconstructive procedures, along with their limitations, in a critical anatomic region. Specific features include the presentation of a workflow using ultra-short implants in a compromised mastoid region. Surgeons should consider alternative implant positions in the event of any compromised mastoid process. A particular emphasis has been put on meticulous aftercare to preserve healthy periimplant soft tissues. PMID:29423354
The removal of a malpositioned implant in the anterior mandible using piezosurgery.
Marini, Ettore; Cisterna, Veronica; Messina, Antonello Maria
2013-05-01
In oral, cranio, and maxillofacial surgery, a close relationship among the bone, nerves, and blood vessels can be regularly observed. Surgical procedures for the removal of dental implants have the potential to cause vascular injury and bleeding in the floor of the mouth and internal anterior region of the mandible. Furthermore, conventional osteotomy techniques always require extensive protection of adjacent soft tissue because cutting is not limited to bone and could easily affect other tissues when applied improperly. We report the removal by means of piezosurgery of a malpositioned osseointegrated implant that had previously caused a sublingual hematoma during its insertion. The postoperative course was uneventful, no bleeding, infection, or hematoma formation was noted and the patient reported 100% resolution of all symptoms. Copyright © 2013 Elsevier Inc. All rights reserved.
Stein, Jamal M; Hammächer, Christian; Michael, Sareh Said-Yekta
2017-12-05
The aim of this study is to evaluate clinical outcomes of a concept for non-surgical peri-implantitis combining stepwise mechanical debridement measures with adjuvant povidone-iodine application with and without systemic antibiotics. Forty-five patients with chronic periodontitis and a total of 164 screw-typed implants with peri-implantitis were included. Peri-implantitis was defined as radiographic bone loss of > 2 mm, probing depth (PD) ≥5 mm with bleeding on probing (BOP). Stepwise treatment of implants was performed with ultrasonic debridement, soft tissue curettage (STC), glycine powder air polishing (GPAP), and a repeated submucosal application of povidone-iodine. Teeth with PD > 4 mm were treated simultaneously according to the same concept except STC. In cases with severe periodontitis (n = 24), amoxicillin and metronidazole (AM) were prescribed for 7 days. After 12 months, implants treated without AM showed significant reductions (P < 0.05) of mean PD (1.4 ± 0.7 mm), clinical attachment level (CAL) (1.3 ± 0.8 mm), and BOP (33.4% ± 17.2%). In deep pockets (PD > 6 mm) changes of mean PD (2.3 ± 1.3 mm), CAL (2.0 ± 1.6 mm), and BOP (44.0% ± 41.7%) were more pronounced. Intake of AM did not significantly influence the changes in these parameters. However, the reduction of implant sites with PD > 4 mm and BOP was significantly higher in patients with AM than in those without AM (31.8% ± 12.6% versus 20.8% ± 14.7%; P < 0.05). The combination of ultrasonic debridement, STC, and GPAP with adjuvant povidone-iodine led to significant clinical improvements at implants. Systemic antibiotics had limited effects on the reduction of persisting implant sites with treatment need. © 2017 American Academy of Periodontology.
Platelet-rich plasma (PRP) in dental and oral surgery: from the wound healing to bone regeneration
2013-01-01
Platelet-rich plasma (PRP) is a new approach to tissue regeneration and it is becoming a valuable adjunct to promote healing in many procedures in dental and oral surgery, especially in aging patients. PRP derives from the centrifugation of the patient's own blood and it contains growth factors that influence wound healing, thereby playing an important role in tissue repairing mechanisms. The use of PRP in surgical practice could have beneficial outcomes, reducing bleeding and enhancing soft tissue healing and bone regeneration. Studies conducted on humans have yielded promising results regarding the application of PRP to many dental and oral surgical procedures (i.e. tooth extractions, periodontal surgery, implant surgery). The use of PRP has also been proposed in the management of bisphosphonate-related osteonecrosis of the jaw (BRONJ) with the aim of enhancing wound healing and bone maturation. The aims of this narrative review are: i) to describe the different uses of PRP in dental surgery (tooth extractions and periodontal surgery) and oral surgery (soft tissues and bone tissue surgery, implant surgery and BRONJ surgery); and ii) to discuss its efficacy, efficiency and risk/benefit ratio. This review suggests that the use of PRP in the alveolar socket after tooth extractions is certainly capable of improving soft tissue healing and positively influencing bone regeneration but the latter effect seems to decrease a few days after the extraction. PRP has produced better results in periodontal therapy in association with other materials than when it is used alone. Promising results have also been obtained in implant surgery, when PRP was used in isolation as a coating material. The combination of necrotic bone curettage and PRP application seem to be encouraging for the treatment of refractory BRONJ, as it has proven successful outcomes with minimal invasivity. Since PRP is free from potential risks for patients, not difficult to obtain and use, it can be employed as a valid adjunct in many procedures in oral and dental surgery. However, further RCTs are required to support this evidence. PMID:23763951
Platelet-rich plasma (PRP) in dental and oral surgery: from the wound healing to bone regeneration.
Albanese, Antonino; Licata, Maria E; Polizzi, Bianca; Campisi, Giuseppina
2013-06-13
Platelet-rich plasma (PRP) is a new approach to tissue regeneration and it is becoming a valuable adjunct to promote healing in many procedures in dental and oral surgery, especially in aging patients. PRP derives from the centrifugation of the patient's own blood and it contains growth factors that influence wound healing, thereby playing an important role in tissue repairing mechanisms. The use of PRP in surgical practice could have beneficial outcomes, reducing bleeding and enhancing soft tissue healing and bone regeneration. Studies conducted on humans have yielded promising results regarding the application of PRP to many dental and oral surgical procedures (i.e. tooth extractions, periodontal surgery, implant surgery). The use of PRP has also been proposed in the management of bisphosphonate-related osteonecrosis of the jaw (BRONJ) with the aim of enhancing wound healing and bone maturation. The aims of this narrative review are: i) to describe the different uses of PRP in dental surgery (tooth extractions and periodontal surgery) and oral surgery (soft tissues and bone tissue surgery, implant surgery and BRONJ surgery); and ii) to discuss its efficacy, efficiency and risk/benefit ratio. This review suggests that the use of PRP in the alveolar socket after tooth extractions is certainly capable of improving soft tissue healing and positively influencing bone regeneration but the latter effect seems to decrease a few days after the extraction. PRP has produced better results in periodontal therapy in association with other materials than when it is used alone. Promising results have also been obtained in implant surgery, when PRP was used in isolation as a coating material. The combination of necrotic bone curettage and PRP application seem to be encouraging for the treatment of refractory BRONJ, as it has proven successful outcomes with minimal invasivity. Since PRP is free from potential risks for patients, not difficult to obtain and use, it can be employed as a valid adjunct in many procedures in oral and dental surgery. However, further RCTs are required to support this evidence.
Discoloration of the Peri-implant Mucosa Caused by Zirconia and Titanium Implants.
Thoma, Daniel S; Ioannidis, Alexis; Cathomen, Elena; Hämmerle, Christoph H F; Hüsler, Jürg; Jung, Ronald E
2016-01-01
The aim of the present study was to assess the discoloration of the peri-implant mucosa caused by zirconia (Zr) and titanium (Ti) dental implants with and without soft tissue grafting (STG). Zr and Ti implants were inserted in edentulous areas in pig maxillae. Spectrophotometric measurements were performed prior to and after the insertion of the implants, and following the placement of a STG on the buccal side. A significant discoloration of the mucosa was observed with a mean ΔE of 8.05 (± 2.51) (Ti) and 4.93 (± 3.18) (Zr). In conjunction with a STG, ΔE values amounted to 5.31 ± 3.50 (Ti) and 5.95 (± 3.68) (Zr). The placement of Zr implants led to less discoloration of the mucosa than Ti implants without STG.
Efficacy of decontamination protocol by antimicrobial treatment in Iranian Tissue Bank (ITB).
Dashti-Khavidaki, Simin; Dabardani, Fariba; Mahdavi-Mazdeh, Mitra; Ravanasa, Elham; Hosseini, Seyed Kazem
2015-09-01
Iranian Tissue Bank established in 1994 provides soft tissues for implantation in Iran. This study was designed to evaluate the efficacy of decontamination process of cardiac and soft tissues in Iranian Tissue Bank. In this bank after initial assessments, the tissues were incubated in a 5-antibiotic cocktail at room temperature for 24 h and then at 4 °C for 14 days. Contamination status was compared before and after antibiotic cocktail incubation. Of 3,315 assessed tissues, 1,057 were pericardia, 1,051 were fascia and 1,207 were other soft tissues including tibialis and aorta. The initial contamination rate was 36.86%. Pericardia showed the highest contamination rate. Klebsiella species was the most prevalent organism causing contamination. Decontamination rate after antibiotic incubation was 86.91% with the highest successful decontamination rate for fascia tissue. Klebsiella species was the major source of contamination in tissues that remained contaminated after antibiotic incubation. This may be due to resistance of this organism to applied antibiotics in the decontamination cocktail possibly due to a negative drug interaction between aminoglycoside and penicillin derivatives in this antibiotic cocktail. In conclusion collected data shows comparable efficacy of the decontamination process that is used in ITB compared with homograft banks of other countries.
Development of dopant-free conductive bioelastomers
Xu, Cancan; Huang, Yihui; Yepez, Gerardo; Wei, Zi; Liu, Fuqiang; Bugarin, Alejandro; Tang, Liping; Hong, Yi
2016-01-01
Conductive biodegradable materials are of great interest for various biomedical applications, such as tissue repair and bioelectronics. They generally consist of multiple components, including biodegradable polymer/non-degradable conductive polymer/dopant, biodegradable conductive polymer/dopant or biodegradable polymer/non-degradable inorganic additives. The dopants or additives induce material instability that can be complex and possibly toxic. Material softness and elasticity are also highly expected for soft tissue repair and soft electronics. To address these concerns, we designed a unicomponent dopant-free conductive polyurethane elastomer (DCPU) by chemically linking biodegradable segments, conductive segments, and dopant molecules into one polymer chain. The DCPU films which had robust mechanical properties with high elasticity and conductivity can be degraded enzymatically and by hydrolysis. It exhibited great electrical stability in physiological environment with charge. Mouse 3T3 fibroblasts survived and proliferated on these films exhibiting good cytocompatibility. Polymer degradation products were non-toxic. DCPU could also be processed into a porous scaffold and in an in vivo subcutaneous implantation model, exhibited good tissue compatibility with extensive cell infiltration over 2 weeks. Such biodegradable DCPU with good flexibility and elasticity, processability, and electrical stability may find broad applications for tissue repair and soft/stretchable/wearable bioelectronics. PMID:27686216
Dai, Jia-Yin; Zhang, Miao-Miao; Sun, Miao; Ni, Hui
2009-06-01
To compare the effect of three kinds of extraction model on high angle bimaxillary protrusion patients. A total of 30 patients with Class I malocclusion and bimaxillary protrusion, aged 14-25 years old, were selected and divided into three groups. Four first premolars were extracted in the first group. The two maxillary first premolars and two mandibular first molars were extracted in the second group. The two maxillary first premolars and two mandibular first molars were extracted in the third group, and two additional micro-implants used as orthodontic anchorage in maxilla. Three groups were all treated with MBT appliance. Cephalometric analysis were carried out before and after treatment, and the results were analyzed with statistics. 1) About the hard tissues, compared with the first group, there were statistically significant differences of N-Me, SGo/NMe, ANS-Me, FH/MP, SN/MP, and ODI in the second and the third group after treatment (P<0.01). 2) About the soft tissues, the teeth and the alveolar bone, compared with the first group, there were statistically significant differences of Pg-Pos, Li-SnPos, Si-LiPos, LL-E, L1-NB, L1/NB, U1/L1, L7-MP in the second and the third group after treatment (P<0.01). 3) All patients received consummate orthodontic treatment and obtained fine occlusion. Facial profiles were improved significantly after orthodontic treatment. 1) After orthodontic treatment with mandibular first molars extraction, FH/MP, SN/MP, N-Me, ANS-Me, L1-NB and L1/NB decreased respectively, and soft tissue profiles were improved significantly. 2) Additional micro-implant used as orthodontic anchorage in maxilla significantly contributed to the maxillary incisor retraction and subsequent soft tissue change. 3) The first molars extraction and additional micro-implant used as orthodontic anchorage are efficient in improving the facial profiles for high angle bimaxillary protrusion patients.
Jensen, Anders Torp; Jensen, Simon Storgård; Worsaae, Nils
2016-06-01
This retrospective clinical study aims to evaluate complications after augmentation of localized bone defects of the alveolar ridge. From standardized registrations, the following complications related to bone augmentation procedures were recorded: soft tissue dehiscence, infection, sensory disturbance, additional augmentation procedures needed, and early implant failure. A total of 223 patients (132 women, 91 men; mean age 23.5 years; range 17-65 years) with 331 bone defects had bone augmentation performed into which 350 implants were placed. Soft tissue dehiscence occurred in 1.7 % after GBR procedures, 25.9 % after staged horizontal ridge augmentation, and 18.2 % after staged vertical ridge augmentation. Infections were diagnosed in 2 % after GBR procedures, 12.5 % after sinus floor elevation (SFE) (transcrestal technique), 5 % after staged SFE, 11 % after staged horizontal ridge augmentation, and 9 % after staged vertical ridge augmentation. Additional augmentation procedures were needed in 2 % after GBR procedures, 37 % after staged horizontal ridge augmentation, and 9 % after staged vertical ridge augmentation. A total of six early implant failures occurred (1.7 %), four after GBR procedures (1.6 %), and two (12 %) after staged vertical ridge augmentation. Predictable methods exist to augment localized defects in the alveolar ridge, as documented by low complication rates and high early implant survival rates.
Boháč, Martin; Danišovič, Ľuboš; Koller, Ján; Dragúňová, Jana; Varga, Ivan
2018-01-22
Acellular matrices are used for various purposes and they have been studied extensively for their potential roles in regenerating tissues or organs. The acellular matrix generates physiological cues that mimic the native tissue microenvironment. Acellular dermal matrix (ADM) is a soft connective tissue graft generated by a decellularization process that preserves the intact extracellular skin matrix. Upon implantation, this structure serves as a scaffold for donor-side cells to facilitate subsequent incorporation and revascularization. In breast reconstruction, ADM is used mainly for lower pole coverage and the shaping of a new breast. It helps control the positioning of the implant in the inframammary fold, and prevent the formation of contractile pseudocapsule around the breast implant. In this study, we provide a comprehensive histological description of ADM used for human breast reconstruction over the course of several months following implementation. Using immunohistochemical methods (a panel of 12 antibodies) coupled with optical and transmission electron microscopy, we confirmed that the original acellular dermal matrix became recolonized by fibroblasts and myofibroblasts, and also by various other free cells of the connective tissue (lymphocytes, macrophages and multinucleated giant cells, granulocytes, mast cells) after implantation into the patient's body. Within the implanted ADM, there was a relatively rapid ingrowth of blood vessels. Lymphatic vessels were only detected in one case 9 months after the implantation of the ADM. These results suggest that lymphangiogenesis is a longer process than angiogenesis.
de Avila, Érica Dorigatti; de Barros-Filho, Luiz Antônio Borelli; de Andrade, Marcelo Ferrarezi; Mollo, Francisco de Assis; de Barros, Luiz Antônio Borelli
2014-01-01
When dental implants are malpositioned in relation to the adjacent teeth and alveolar bone or in an excessive buccal or lingual position, the final prosthesis rehabilitation impairs the peri-implant health of the gingival tissues and the aesthetics of the patient. Thus, the purpose of this case was to report and discuss a multidisciplinary protocol for the treatment of a compromised maxillary tooth in a patient with an abscess in his right central incisor due to an excessive buccal implant position. The patient presented with an implant-supported provisional restoration on his right maxillary central incisor and a traumatic injury in his left central incisor. The treatment protocol consisted in (i) abutment substitution to compensate the incorrect angulation of the implant, (ii) clinical crown lengthening, (iii) atraumatic extraction of the left central incisor, and (iv) immediate implant placement. Finally, (v) a custom abutment was fabricated to obtain a harmonious gingival contour around the prosthetic crown. In conclusion, when implants are incorrectly positioned in relation to the adjacent teeth, associated with soft-tissue defects, the challenge to create a harmonious mucogingival contours may be achieved with an interdisciplinary approach and with the placement of an appropriate custom abutment. PMID:24955259
Restoration of the maxillary arch using implants, natural teeth and the Konus crown: a case study.
Sethi, A; Sochor, P
1994-03-01
Restoring the maxillary arch by using a suprastructure retained by a Konus crown means that the patient can remove the crown for oral hygiene. This construction enables large embrasure spaces to be avoided without compromising phonetics, that is, without adversely affecting the patient's speech. It also enables the dental surgeon to monitor the tooth and implant abutments and the soft tissues around them. In this article we demonstrate successful restoration of the maxillary arch by the use of Konus crowns on a combination of implants and natural teeth.
Latissimus Dorsi Flap in Breast Reconstruction
Sood, Rachita; Easow, Jeena M.; Konopka, Geoffrey; Panthaki, Zubin J.
2018-01-01
Background: Surgeons employ the latissimus dorsi flap (LDF) for reconstruction of a large variety of breast cancer surgery defects, including quadrantectomy, lumpectomy, modified radical mastectomy, and others. The LDF may be used in delayed or immediate reconstruction, in combination with tissue expanders for a staged reconstruction, with implant-based immediate reconstruction, or alone as an autogenous flap. Methods: The authors discuss the historical uses and more recent developments in the LDF. More recent advancements, including the “scarless” approach and augmentation with the thoracodorsal artery perforator flap, are discussed. Results: The LDF is a reliable means for soft tissue coverage providing form and function during breast reconstruction with acceptable perioperative and long-term morbidities. Conclusions: When there is a paucity of tissue, the LDF can provide tissue volume in autologous reconstruction, as well as a reliable vascular pedicle for implant-based reconstruction as in the setting of irradiated tissue. PMID:29334788
Chatzinoff, Yonatan; Szczepanski, Debby; Bing, Chenchen; Shaikh, Sumbul; Wyman, Omar; Perry, Cameron E.; Richardson, James A.; Burns, Dennis K.; Evers, Bret M.; Greenberg, David E.; Chopra, Rajiv
2018-01-01
Treatment of prosthetic joint infections often involves multiple surgeries and prolonged antibiotic administration, resulting in a significant burden to patients and the healthcare system. We are exploring a non-invasive method to eradicate biofilm on metal implants utilizing high-frequency alternating magnetic fields (AMF) which can achieve surface induction heating. Although proof-of-concept studies demonstrate the ability of AMF to eradicate biofilm in vitro, there is a legitimate safety concern related to the potential for thermal damage to surrounding tissues when considering heating implanted metal objects. The goal of this study was to explore the feasibility of detecting acoustic emissions associated with boiling at the interface between a metal implant and surrounding soft tissue as a wireless safety sensing mechanism. Acoustic emissions generated during in vitro and in vivo AMF exposures were captured with a hydrophone, and the relationship with surface temperature analyzed. The effect of AMF exposure power, surrounding media composition, implant location within the AMF transmitter, and implant geometry on acoustic detection during AMF therapy was also evaluated. Acoustic emissions were reliably identified in both tissue-mimicking phantom and mouse studies, and their onset coincided with the implant temperature reaching the boiling threshold. The viscosity of the surrounding medium did not impact the production of acoustic emissions; however, emissions were not present when the medium was oil due to the higher boiling point. Results of simulations and in vivo studies suggest that short-duration, high-power AMF exposures combined with acoustic sensing can be used to minimize the amount of thermal damage in surrounding tissues. These studies support the hypothesis that detection of boiling associated acoustic emissions at a metal/tissue interface could serve as a real-time, wireless safety indicator during AMF treatment of biofilm on metallic implants. PMID:29746579
Cheng, Bingbing; Chatzinoff, Yonatan; Szczepanski, Debby; Bing, Chenchen; Shaikh, Sumbul; Wyman, Omar; Perry, Cameron E; Richardson, James A; Burns, Dennis K; Evers, Bret M; Greenberg, David E; Chopra, Rajiv
2018-01-01
Treatment of prosthetic joint infections often involves multiple surgeries and prolonged antibiotic administration, resulting in a significant burden to patients and the healthcare system. We are exploring a non-invasive method to eradicate biofilm on metal implants utilizing high-frequency alternating magnetic fields (AMF) which can achieve surface induction heating. Although proof-of-concept studies demonstrate the ability of AMF to eradicate biofilm in vitro, there is a legitimate safety concern related to the potential for thermal damage to surrounding tissues when considering heating implanted metal objects. The goal of this study was to explore the feasibility of detecting acoustic emissions associated with boiling at the interface between a metal implant and surrounding soft tissue as a wireless safety sensing mechanism. Acoustic emissions generated during in vitro and in vivo AMF exposures were captured with a hydrophone, and the relationship with surface temperature analyzed. The effect of AMF exposure power, surrounding media composition, implant location within the AMF transmitter, and implant geometry on acoustic detection during AMF therapy was also evaluated. Acoustic emissions were reliably identified in both tissue-mimicking phantom and mouse studies, and their onset coincided with the implant temperature reaching the boiling threshold. The viscosity of the surrounding medium did not impact the production of acoustic emissions; however, emissions were not present when the medium was oil due to the higher boiling point. Results of simulations and in vivo studies suggest that short-duration, high-power AMF exposures combined with acoustic sensing can be used to minimize the amount of thermal damage in surrounding tissues. These studies support the hypothesis that detection of boiling associated acoustic emissions at a metal/tissue interface could serve as a real-time, wireless safety indicator during AMF treatment of biofilm on metallic implants.
Kutkut, Ahmad; Abu-Hammad, Osama; Frazer, Robert
2016-01-01
Impression techniques for implant restorations can be implant level or abutment level impressions with open tray or closed tray techniques. Conventional implant-abutment level impression techniques are predictable for maximizing esthetic outcomes. Restoration of the implant traditionally requires the use of the metal or plastic impression copings, analogs, and laboratory components. Simplifying the dental implant restoration by reducing armamentarium through incorporating conventional techniques used daily for crowns and bridges will allow more general dentists to restore implants in their practices. The demonstrated technique is useful when modifications to implant abutments are required to correct the angulation of malpositioned implants. This technique utilizes conventional crown and bridge impression techniques. As an added benefit, it reduces costs by utilizing techniques used daily for crowns and bridges. The aim of this report is to describe a simplified conventional impression technique for custom abutments and modified prefabricated solid abutments for definitive restorations. PMID:29563457
Abe, Manami; Yang, Tsung-Chieh; Maeda, Yoshionobu; Ando, Takanori; Wada, Masahiro
The purpose of this preliminary in vivo study was to compare force distribution on abutments (tooth or implant) and tissues supporting overdentures with two or four abutments. A convenience sample of five subjects with tooth and/or implant-supported overdentures was enrolled. Recordings were completed on each subject using a force-measuring system mounted on a metal framework with four anteroposterior spread abutments (A), four abutments with denture bases (B), and on two anterior abutments with denture bases (C). The tissue-support ratio (TSR) was calculated as (A-B)/A or (A-C)/A. TSR values changed 1.5 to 2 times when the number of abutments was reduced from four to two. The amount of tissue strain on the posterior residual ridge increased when the number of abutments was reduced.
Immediate loading of implants in the aesthetic zone: comparison between two placement timings.
Carini, Fabrizio; Longoni, Salvatore; Pisapia, Valeria; Francesconi, Manuel; Saggese, Vito; Porcaro, Gianluca
2014-01-01
Implant rehabilitation delivered in accordance with the traditional protocol has proven to be highly predictable and acceptable (1). Nevertheless, the application of immediate loading on post-extraction implants, especially for aesthetic zones, has now considerably increased (2). The aim of this work is to illustrate the immediate loading of implants placed in the aesthetic zone through tapered design fixtures with microgeometry of a high degree of porosity inserted at the same time or 4-8 weeks from dental avulsion (TSA® Advance, Phibo®). A total of 15 implant fixtures of which 8 at an interval of 4-8 weeks from extraction (type 2) and the remaining according to the immediate post-extraction technique (type 1) were positioned. All implants were prosthesized within 24 hours from the placement. Definitive crowns replaced provisional restorations after 20-24 weeks. After 4 and 12 months from implant insertion, the following parameters were assessed: X-ray image, pain, mobility or suppuration, soft tissue condition and aesthetic appearance. Percentage of osseointegration was 93.75%, and 53.5% of the osseointegrated fixtures was type 2. No statistically significant difference between the mean ISQ values for implants of type 1 and 2 both in the post-operative period and after 12 months was evident, indicating that the timing of insertion did not affect the achievement of stability for the implant fixtures tested in our study. Immediate post-extraction implants showed a greater propensity for gingival recession and a peri-implant radiolucency greater than those placed at an interval of 4-8 weeks. The values obtained for the PES/WES and the subjective evaluation of the analyzed sample showed the considerable aesthetic value and the high level of satisfaction guaranteed by the implant technique illustrated. Although well-designed, high quality, randomized clinical trials are still needed as well as the requirement to establish a common, complete, and reproducible index for the evaluation of aesthetic outcome, immediate/early placement and loading of a single TSA® Advance, Phibo® may be considered a valuable and predictable option in terms of implant success as well as hard and soft tissue stability.
2013-01-01
Background In this study we evaluated a novel approach to guide the bone marrow-driven articular cartilage repair response in skeletally aged rabbits. We hypothesized that dispersed chitosan particles implanted close to the bone marrow degrade in situ in a molecular mass-dependent manner, and attract more stromal cells to the site in aged rabbits compared to the blood clot in untreated controls. Methods Three microdrill hole defects, 1.4 mm diameter and 2 mm deep, were created in both knee trochlea of 30 month-old New Zealand White rabbits. Each of 3 isotonic chitosan solutions (150, 40, 10 kDa, 80% degree of deaceylation, with fluorescent chitosan tracer) was mixed with autologous rabbit whole blood, clotted with Tissue Factor to form cylindrical implants, and press-fit in drill holes in the left knee while contralateral holes received Tissue Factor or no treatment. At day 1 or day 21 post-operative, defects were analyzed by micro-computed tomography, histomorphometry and stereology for bone and soft tissue repair. Results All 3 implants filled the top of defects at day 1 and were partly degraded in situ at 21 days post-operative. All implants attracted neutrophils, osteoclasts and abundant bone marrow-derived stromal cells, stimulated bone resorption followed by new woven bone repair (bone remodeling) and promoted repair tissue-bone integration. 150 kDa chitosan implant was less degraded, and elicited more apoptotic neutrophils and bone resorption than 10 kDa chitosan implant. Drilled controls elicited a poorly integrated fibrous or fibrocartilaginous tissue. Conclusions Pre-solidified implants elicit stromal cells and vigorous bone plate remodeling through a phase involving neutrophil chemotaxis. Pre-solidified chitosan implants are tunable by molecular mass, and could be beneficial for augmented marrow stimulation therapy if the recruited stromal cells can progress to bone and cartilage repair. PMID:23324433
Characterization of the Reproductive Toxicity of Depleted Uranium
2005-06-01
thymus, kidney, liver, skeletal muscle, uterus, ovaries, testes, bone marrow. Requested tissues were identified, embedded in paraffin and trimmed...located (all but 2-females), a cross section of the uterus was processed for evaluation. Each sample of skeletal muscle was bread-loafed in an attempt...correlation with the formation of soft tissue sarcomas . In contrast, none of these three animal’s implant sites showed evidence of a proliferative or
Bhaskar, Vaishnavi; Chan, Hsun-Liang; MacEachern, Mark; Kripfgans, Oliver D
2018-05-23
Ultrasonography has shown promising diagnostic value in dental implant imaging research; however, exactly how ultrasound was used and at what stage of implant therapy it can be applied has not been systematically evaluated. Therefore, the aim of this review is to investigate potential indications of ultrasound use in the three implant treatment phases, namely planning, intraoperative and postoperative phase. Eligible manuscripts were searched in major databases with a combination of key words related to the use of ultrasound imaging in implant therapy. An initial search yielded 414 articles, after further review, 28 articles were finally included for this systematic review. Ultrasound was found valuable, though at various development stages, for evaluating (1) soft tissues, (2) hard tissues (3) vital structures and (4) implant stability. B-mode, the main function to image anatomical structures of interest, has been evaluated in pre-clinical and clinical studies. Quantitative ultrasound parameters, e.g. sound speed and amplitude, are being developed to evaluate implant-bone stability, mainly in simulation and pre-clinical studies. Ultrasound could be potentially useful in all 3 treatment phases. In the planning phase, ultrasound could evaluate vital structures, tissue biotype, ridge width/density, and cortical bone thickness. During surgery, it can provide feedback by identifying vital structures and bone boundary. At follow-up visits, it could evaluate marginal bone level and implant stability. Understanding the current status of ultrasound imaging research for implant therapy would be extremely beneficial for accelerating translational research and its use in dental clinics.
Han, Yan; Zhao, Jianhui; Tao, Ran; Guo, Lingli; Yang, Hongyan; Zeng, Wei; Song, Baoqiang; Xia, Wensen
2017-09-01
Craniomaxillofacial traumatic soft tissue defects severely affect the function and appearance of the patients. The traditional skin grafting or free flap transplantation can only close the defects in the early stage of operation but cannot ensure similar color, texture, and relative aesthetic contour. In the present study, the authors have explored a novel strategy to repair craniomaxillofacial traumatic soft tissue defects by tissue expansion in the early stage and have obtained satisfactory results. Eighteen patients suffering large craniomaxillofacial traumatic soft tissue defects were treated by thorough debridement leaving the wounds unclosed or simply closed with thin split-thickness scalp grafts, adjacent expander implantation in the first stage, and expanded flap transposition in the second stage. There were 11 male patients and 7 female patients ranging in age from 3.5 to 40 years (mean, 19.4 ± 12.2 years), with average 15 months follow-up (range, 3-67 months). The average expansion time was 74.3 days (range, 53-96 days). The 18 patients with a total of 22 expanders were treated with satisfactory results. All the flaps survived and the skin color, texture, and contour well matched those of the peripheral tissue. Only 1 complication of infection happened in the 18 cases (5.56%) and the 22 expanders (4.55%), which was similar to the rate reported in the literature. No other complications related to the expanders occurred. Debridement and tissue expansion in the early stage has been proved to be a more effective strategy to repair craniomaxillofacial traumatic soft tissue defects. This strategy can not only achieve satisfactory color, unbulky and well-matched texture similar to normal, but also avoid unnecessary donor site injuries.
Necrotic and inflammatory changes in metal-on-metal resurfacing hip arthroplasties
2009-01-01
Background Necrosis and inflammation in peri-implant soft tissues have been described in failed second-generation metal-on-metal (MoM) resurfacing hip arthroplasties and in the pseudotumors associated with these implants. The precise frequency and significance of these tissue changes is unknown. Method We analyzed morphological and immunophenotypic changes in the periprosthetic soft tissues and femoral heads of 52 revised MoM arthroplasties (fracture in 21, pseudotumor in 13, component loosening in 9, and other causes in 9 cases). Results Substantial necrosis was observed in the periprosthetic connective tissue in 28 of the cases, including all pseudotumors, and 5 cases of component loosening. A heavy, diffuse inflammatory cell infiltrate composed mainly of HLA-DR+/CD14+/CD68+ macrophages and CD3+ T cells was seen in 45 of the cases. Perivascular lymphoid aggregates composed of CD3+ cells and CD20+ B cells were noted in 27 of the cases, but they were not seen in all cases of component loosening or pseudotumors. Plasma cells were noted in 30 cases. Macrophage granulomas were noted in 6 cases of component loosening. In the bone marrow of the femoral head, a macrophage and T cell response was seen in 31 of the cases; lymphoid aggregates were noted in 19 of the cases and discrete granulomas in 1 case. Interpretation Our findings indicate that there is a spectrum of necrotic and inflammatory changes in response to the deposition of cobalt-chrome (Co-Cr) wear particles in periprosthetic tissues. Areas of extensive coagulative necrosis and a macrophage and T lymphocyte response occur in implant failure and pseudotumors, in which there is also granuloma formation. The pathogenesis of these changes is uncertain but it may involve both a cytotoxic response and a delayed hypersensitivity (type IV) response to Co-Cr particles. PMID:19995315
Chronic tissue response to untethered microelectrode implants in the rat brain and spinal cord
NASA Astrophysics Data System (ADS)
Ersen, Ali; Elkabes, Stella; Freedman, David S.; Sahin, Mesut
2015-02-01
Objective. Microelectrodes implanted in the central nervous system (CNS) often fail in long term implants due to the immunological tissue response caused by tethering forces of the connecting wires. In addition to the tethering effect, there is a mechanical stress that occurs at the device-tissue interface simply because the microelectrode is a rigid body floating in soft tissue and it cannot reshape itself to comply with changes in the surrounding tissue. In the current study we evaluated the scar tissue formation to tetherless devices with two significantly different geometries in the rat brain and spinal cord in order to investigate the effects of device geometry. Approach. One of the implant geometries resembled the wireless, floating microstimulators that we are currently developing in our laboratory and the other was a (shank only) Michigan probe for comparison. Both electrodes were implanted into either the cervical spinal cord or the motor cortices, one on each side. Main results. The most pronounced astroglial and microglial reactions occurred within 20 μm from the device and decreased sharply at larger distances. Both cell types displayed the morphology of non-activated cells past the 100 μm perimeter. Even though the aspect ratios of the implants were different, the astroglial and microglial responses to both microelectrode types were very mild in the brain, stronger and yet limited in the spinal cord. Significance. These observations confirm previous reports and further suggest that tethering may be responsible for most of the tissue response in chronic implants and that the electrode size has a smaller contribution with floating electrodes. The electrode size may be playing primarily an amplifying role to the tethering forces in the brain whereas the size itself may induce chronic response in the spinal cord where the movement of surrounding tissues is more significant.
NASA Astrophysics Data System (ADS)
Kim, Dae-Hyeong; Lee, Mincheol; Lee, Hyunjae
2016-05-01
Recent advances in soft electronics have attracted great attention, largely due to their potential applications in personalized, bio-integrated healthcare devices. The mechanical mismatch between conventional electronic/optoelectronic devices and soft human tissues/organs have presented many challenges, such as the low signalto- noise ratio of biosensors because of the incomplete integration of rigid devices with the body, inflammation and excessive immune responses of implanted stiff devices originated from friction and their foreign nature to biotic systems, and the considerable discomfort and consequent stress experienced by users when wearing/implanting these devices. Ultra-flexible and stretchable electronic devices are being highlighted due to their low system modulus and the intrinsic system-level softness that are important to solve these issues. Here, we describe our unique strategies for the nanomaterial synthesis and fabrication, their seamless assembly and integration, and the design and development of corresponding wearable healthcare devices and minimally invasive surgical tools. These bioelectronic systems fully utilize recent breakthroughs in unconventional soft electronics based on nanomaterials to address unsolved issues in clinical medicine and to provide new opportunities in the personalized healthcare.
Da, Lincui; Gong, Mei; Chen, Anjing; Zhang, Yi; Huang, Yizhou; Guo, Zhijun; Li, Shengfu; Li-Ling, Jesse; Zhang, Li; Xie, Huiqi
2017-09-01
Although soft tissue replacement has been clinically successful in many cases, the corresponding procedure has many limitations including the lack of resilience and mechanical integrity, significant donor-site morbidity, volume loss with time, and fibrous capsular contracture. These disadvantages can be alleviated by utilizing bio-absorbable scaffolds with high resilience and large strain, which are capable of stimulating natural tissue regeneration. Hence, the chemically crosslinked tridimensional scaffolds obtained by incorporating water-based polyurethane (PU) (which was synthesized from polytetramethylene ether glycol, isophorone diisocyanate, and 2,2-bis(hydroxymethyl) butyric acid) into a bioactive extracellular matrix consisting of small intestinal submucosa (SIS) have been tested in this study to develop a new approach for soft tissue engineering. After characterizing the structure and properties of the produced PU/SIS composites, the strength, Young's modulus, and resilience of wet PU/SIS samples were compared with those of crosslinked PU. In addition, the fabricated specimens were investigated using human umbilical vein endothelial cells to evaluate their ability to enhance cell attachment and proliferation. As a result, the synthesized PU/SIS samples exhibited high resilience and were capable of enhancing cell viability with no evidence of cytotoxicity. Subcutaneous implantation in animals and the subsequent testing conducted after 2, 4, and 8weeks indicated that sound implant integration and vascularization occurred inside the PU/SIS composites, while the presence of SIS promoted cell infiltration, angiogenesis, and ultimately tissue regeneration. The obtained results revealed that the produced PU/SIS composites were characterized by high bioactivity and resilience, and, therefore, could be used for soft tissue engineering applications. Hybrid composites containing synthetic polymers with high mechanical strength and naturally derived components, which create a bio-mimetic environment, are one of the most promising biomaterials. Although synthetic polymer/ECM composites have been previously used for soft tissue repair, their resilience properties were not investigated in sufficient detail, while the development of elastic composites composed of synthetic polymers and ECMs in nontoxic aqueous solutions remains a rather challenging task. In this study, porous PU/SIS composites were fabricated in a non-toxic manner; the obtained materials exhibited sufficient mechanical support, which promote cell growth, angiogenesis, and tissue regeneration. The described method can be adapted for the development of scaffolds with various acellular matrices and subsequently used during the restoration of particular types of tissue. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
MR Imaging of Knee Arthroplasty Implants
Fritz, Jan; Lurie, Brett
2015-01-01
Primary total knee arthroplasty is a highly effective treatment that relieves pain and improves joint function in a large percentage of patients. Despite an initially satisfactory surgical outcome, pain, dysfunction, and implant failure can occur over time. Identifying the etiology of complications is vital for appropriate management and proper timing of revision. Due to the increasing number of knee arthroplasties performed and decreasing patient age at implantation, there is a demand for accurate diagnosis to determine appropriate treatment of symptomatic joints following knee arthroplasty, and for monitoring of patients at risk. Magnetic resonance (MR) imaging allows for comprehensive imaging evaluation of the tissues surrounding knee arthroplasty implants with metallic components, including the polyethylene components. Optimized conventional and advanced pulse sequences can result in substantial metallic artifact reduction and afford improved visualization of bone, implant-tissue interfaces, and periprosthetic soft tissue for the diagnosis of arthroplasty-related complications. In this review article, we discuss strategies for MR imaging around knee arthroplasty implants and illustrate the imaging appearances of common modes of failure, including aseptic loosening, polyethylene wear–induced synovitis and osteolysis, periprosthetic joint infections, fracture, patellar clunk syndrome, recurrent hemarthrosis, arthrofibrosis, component malalignment, extensor mechanism injury, and instability. A systematic approach is provided for evaluation of MR imaging of knee implants. MR imaging with optimized conventional pulse sequences and advanced metal artifact reduction techniques can contribute important information for diagnosis, prognosis, risk stratification, and surgical planning. ©RSNA, 2015 PMID:26295591
MRI Near Metallic Implants Using MAVRIC SL: Initial Clinical Experience at 3T
Gutierrez, Luis B.; Do, Bao H.; Gold, Garry E.; Hargreaves, Brian A.; Koch, Kevin M.; Worters, Pauline W.; Stevens, Kathryn J.
2014-01-01
Rationale and Objectives To compare the effectiveness of MAVRIC SL with conventional 2D-FSE MR techniques at 3T in imaging patients with a variety of metallic implants. Materials and Methods Twenty-one 3T MR studies were obtained in 19 patients with different types of metal implants. Paired MAVRIC SL and 2D-FSE sequences were reviewed by 2 radiologists, and compared for in-plane and through-plane metal artifact, visualization of the bone implant interface and surrounding soft tissues, blurring, and overall image quality using a 2-tailed Wilcoxon signed rank test. The area of artifact on paired images was measured and compared using a paired Wilcoxon signed rank test. Changes in patient management resulting from MAVRIC SL imaging were documented. Results Significantly less in-plane and through-plane artifact was seen with MAVRIC SL, with improved visualization of the bone-implant interface and surrounding soft tissues, and superior overall image quality (p = 0.0001). Increased blurring was seen with MAVRIC SL (p=0.0016). MAVRIC SL significantly decreased the image artifact compared to 2D-FSE (p=0.0001). Inclusion of MAVRIC SL to the imaging protocol determined the need for surgery or type of surgery in 5 patients, and ruled out the need for surgery in 13 patients. In 3 patients the area of interest was well seen on both MAVRIC SL and 2D-FSE images, so the addition of MAVRIC had no effect on patient management. Conclusion Imaging around metal implants with MAVRIC SL at 3T significantly improved image quality and decreased image artifact compared to conventional 2D-FSE imaging techniques, and directly impacted patient management. PMID:25435186
MR imaging near metallic implants using MAVRIC SL: initial clinical experience at 3T.
Gutierrez, Luis B; Do, Bao H; Gold, Garry E; Hargreaves, Brian A; Koch, Kevin M; Worters, Pauline W; Stevens, Kathryn J
2015-03-01
To compare the effectiveness of multiacquisition with variable resonance image combination selective (MAVRIC SL) with conventional two-dimensional fast spin-echo (2D-FSE) magnetic resonance (MR) techniques at 3T in imaging patients with a variety of metallic implants. Twenty-one 3T MR studies were obtained in 19 patients with different types of metal implants. Paired MAVRIC SL and 2D-FSE sequences were reviewed by two radiologists and compared for in-plane and through-plane metal artifact, visualization of the bone implant interface and surrounding soft tissues, blurring, and overall image quality using a two-tailed Wilcoxon signed rank test. The area of artifact on paired images was measured and compared using a paired Wilcoxon signed rank test. Changes in patient management resulting from MAVRIC SL imaging were documented. Significantly less in-plane and through-plane artifact was seen with MAVRIC SL, with improved visualization of the bone-implant interface and surrounding soft tissues, and superior overall image quality (P = .0001). Increased blurring was seen with MAVRIC SL (P = .0016). MAVRIC SL significantly decreased the image artifact compared to 2D-FSE (P = .0001). Inclusion of MAVRIC SL to the imaging protocol determined the need for surgery or type of surgery in five patients and ruled out the need for surgery in 13 patients. In three patients, the area of interest was well seen on both MAVRIC SL and 2D-FSE images, so the addition of MAVRIC had no effect on patient management. Imaging around metal implants with MAVRIC SL at 3T significantly improved image quality and decreased image artifact compared to conventional 2D-FSE imaging techniques and directly impacted patient management. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Gibbons, D. F.
1977-01-01
The objectives in this report were to use the ion beam sputtering technique to produce surface textures on polymers, metals, and ceramics. The morphology of the texture was altered by varying both the width and depth of the square pits which were formed by ion beam erosion. The width of the ribs separating the pits were defined by the mask used to produce the texture. The area of the surface containing pits varies as the width was changed. The biological parameters used to evaluate the biological response to the texture were: (1) fibrous capsule and inflammatory response in subcutaneous soft tissue; (2) strength of the mechanical attachment of the textured surface by the soft tissue; and (3) morphology of the epidermal layer interfacing the textured surface of percutaneous connectors. Because the sputter yield on teflon ribs was approximately an order of magnitude larger than any other material the majority of the measurements presented in the report were obtained with teflon.
NASA Astrophysics Data System (ADS)
Covarrubias, Cristian; Mattmann, Matías; Von Marttens, Alfredo; Caviedes, Pablo; Arriagada, Cristián; Valenzuela, Francisco; Rodríguez, Juan Pablo; Corral, Camila
2016-02-01
The fabrication of a nanoporous silica coating loaded with bioactive glass nanoparticles (nBG/NSC) on titanium dental implant surface and its in vitro and in vivo evaluation is presented. The coating was produced by a combined sol-gel and evaporation induced self-assembly process. In vitro bioactivity was assessed in simulated body fluid (SBF) and investigating the osteogenic differentiation of human bone marrow mesenchymal stem cells (hBMSCs). A rat tibial model was employed to analyze the bone response to nBG/NSC-modified titanium implant surface in vivo. The nBG/NSC coating was confirmed at nano level to be constituted by a highly ordered nanoporous silica structure. The coating nanotopography in conjunction with the bioactivity of the BG particles accelerate the in vitro apatite formation and promote the osteogenic differentiation of hBMSCs in absence of osteogenic supplements. These properties accelerate the formation of bone tissue in the periphery of the implant after 3 weeks of implantation. Backscattered scanning electron microscopy images revealed the presence of gaps and soft tissue in the unmodified implant after 6 weeks, whereas the nBG/NSC-modified implant showed mature bone in intimate contact with the implant surface. The nBG/NSC coating appears promising for accelerating the osseointegration of dental implants.
[A PhD completed 3. Soft tissue development around an implant in the aesthetic zone].
Patil, R C
2016-01-01
A randomised clinical trial was carried out in order to determine whether changes in the abutment design result in improved quality of the peri-implant mucosal tissue according to the parameters attachment strength, sotft tissue stability and developmemt, and maintenance of bone levels. Twenty-nine patients were included. They received 2, non-adjacent endosseous implants replacing missing teeth in the aesthetic zone. Subsequently, conventional (control) and experimental abutments (with an additional macro groove of about 0.5 mm in depth ) were placed. After 6 weeks and 1 year the effect of the 2 different abutment designs were measured according to the specified parameters. In addition, patients' and dentists' satisfaction concerning the muco-gingival results were compared. It was concluded that the 2 abutments produced no significantly different effect on muco-gingival aesthetics. On the basis of additional comparative research between Caucasian and Indian individuals it was concluded that the gingival biotype could best be determined quantitatively.
Nanoscale hydroxyapatite particles for bone tissue engineering.
Zhou, Hongjian; Lee, Jaebeom
2011-07-01
Hydroxyapatite (HAp) exhibits excellent biocompatibility with soft tissues such as skin, muscle and gums, making it an ideal candidate for orthopedic and dental implants or components of implants. Synthetic HAp has been widely used in repair of hard tissues, and common uses include bone repair, bone augmentation, as well as coating of implants or acting as fillers in bone or teeth. However, the low mechanical strength of normal HAp ceramics generally restricts its use to low load-bearing applications. Recent advancements in nanoscience and nanotechnology have reignited investigation of nanoscale HAp formation in order to clearly define the small-scale properties of HAp. It has been suggested that nano-HAp may be an ideal biomaterial due to its good biocompatibility and bone integration ability. HAp biomedical material development has benefited significantly from advancements in nanotechnology. This feature article looks afresh at nano-HAp particles, highlighting the importance of size, crystal morphology control, and composites with other inorganic particles for biomedical material development. Copyright © 2011 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Matsumoto, Tomoyuki; Shibanuma, Nao; Takayama, Koji; Sasaki, Hiroshi; Ishida, Kazunari; Matsushita, Takehiko; Kuroda, Ryosuke; Kurosaka, Masahiro
2016-06-01
Appropriate soft tissue balance is essential for the success of total knee arthroplasty (TKA), and assessment with an offset-type tensor provides useful information about the femorotibial (FT) joint. The purpose of the study was to investigate the relationship between intraoperative soft tissue balance and patellar pressure at both medial and lateral sides. Thirty varus-type osteoarthritis patients who received mobile-bearing posterior-stabilized TKAs were enrolled in the study. Using the tensor, soft tissue balance, including joint component gap and varus ligament balance, was recorded at 0°, 10°, 30°, 60°, 90°, 120°, and 135° with patellofemoral (PF) joint reduction and femoral component placement. Following final prostheses implanted with appropriate insert, the medial and lateral patellar pressures were measured at each flexion angle. A simple regression analysis was performed between each patellar pressure, parameter of soft tissue balance, and postoperative flexion angle. Both lateral and medial patellar pressures increased with flexion. The lateral patellar pressure was significantly higher than the medial patellar pressure at 60°, 90°, and 135° of flexion (p<0.05). The lateral patellar pressure inversely correlated with the varus ligament balance at 60° and 90° of flexion (p<0.05). The lateral patellar pressure at 120° and 135° of flexion inversely correlated with the postoperative flexion angle (p<0.05). Soft tissue balance influenced patellar pressure. In particular, a reduced lateral patellar pressure was found at the lateral laxity at flexion, leading to high postoperative flexion angle. III. Copyright © 2016 Elsevier B.V. All rights reserved.
Hahn, Michael; Busse, Björn; Procop, Mathias; Zustin, Jozef; Amling, Michael; Katzer, Alexander
2017-10-01
Most resurfacing systems are manufactured from cobalt-chromium alloys with metal-on-metal (MoM) bearing couples. Because the quantity of particulate metal and corrosion products which can be released into the periprosthetic milieu is greater in MoM bearings than in metal-on-polyethylene (MoP) bearings, it is hypothesized that the quantity and distribution of debris released by the MoM components induce a compositional change in the periprosthetic bone. To determine the validity of this claim, nondestructive µ-X-ray fluorescence analysis was carried out on undecalcified histological samples from 13 femoral heads which had undergone surface replacement. These samples were extracted from the patients after gradient time points due to required revision surgery. Samples from nonintervened femoral heads as well as from a MoP resurfaced implant served as controls. Light microscopy and µ-X-ray fluorescence analyses revealed that cobalt debris was found not only in the soft tissue around the prosthesis and the bone marrow, but also in the mineralized bone tissue. Mineralized bone exposed to surface replacements showed significant increases in cobalt concentrations in comparison with control specimens without an implant. A maximum cobalt concentration in mineralized hard tissue of up to 380 ppm was detected as early as 2 years after implantation. Values of this magnitude are not found in implants with a MoP surface bearing until a lifetime of more than 20 years. This study demonstrates that hip resurfacing implants with MoM bearings present a potential long-term health risk due to rapid cobalt ion accumulation in periprosthetic hard tissue. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1855-1862, 2017. © 2016 Wiley Periodicals, Inc.
Lasers in oral surgery and implantology
NASA Astrophysics Data System (ADS)
Vescovi, Paolo
2016-03-01
The usefulness of laser for oral hard tissue procedure such as caries treatment, impacted teeth extraction, periodontal therapy, peri-implantitis management, sinus lifting is reported by several Authors [1]. Conventionally, mechanical rotary instruments and hand instruments are employed for bone surgery. Rotary instruments have better accessibility and cutting efficiency, but there is a risk of excessive heating of bone tissue and caution must be exercised to avoid the bur becoming entangled with surrounding soft tissues and the reflected flap. The main clinical advantages of the lasers are represented by minimal patient discomfort, good recovery with decreased or absent post-operative pain. In the last ten years are described in the international literature great advantages of Laser Surgery and Low Level Laser Therapy (LLLT) performed with different wavelength in addition to traditional surgical techniques to improve bone and soft tissue healing and for pain and infection control.
Finelle, Gary; Lee, Sang J
Digital technology has been widely used in the field of implant dentistry. From a surgical standpoint, computer-guided surgery can be utilized to enhance primary implant stability and to improve the precision of implant placement. From a prosthetic standpoint, computer-aided design/computer-assisted manufacture (CAD/CAM) technology has brought about various restorative options, including the fabrication of customized abutments through a virtual design based on computer-guided surgical planning. This case report describes a novel technique combining the use of a three-dimensional (3D) printed surgical template for the immediate placement of an implant, with CAD/CAM technology to optimize hard and soft tissue healing after bone grafting with the use of a socket sealing abutment.
Efficacy and safety of a diode laser in second-stage implant surgery: a comparative study.
El-Kholey, K E
2014-05-01
For more than a decade, peri-implant tissues have been treated with soft tissue lasers to create a bloodless flap for implant placement and to uncover implants with minimal bleeding, trauma, and anaesthesia. This study was designed to assess if dental implant uncovering is possible with a diode laser without anaesthesia, and to compare its performance with traditional cold scalpel surgery. Thirty patients with a total of 45 completely osseointegrated implants participated in this study. Patients were divided into two groups. For the study group, second-stage implant surgery was done with a 970nm diode laser. For the control group, the implants were exposed with a surgical blade. Certain parameters were used for evaluation of the two techniques. The use of the diode laser obviated the need for local anaesthesia; there was a significant difference between the two groups regarding the need for anaesthesia (P<0.0001). However, there were no significant differences between the two techniques regarding duration of surgery, postoperative pain, time for healing, and success of the implants. The diode laser can be used effectively for second-stage implant surgery, providing both the dentist and the patient with additional advantages over the conventional methods used for implant exposure. Copyright © 2013 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Keefe, Morgan S; Keefe, Michael A
2009-01-01
Reconstruction in the head and neck can be difficult owing to the size of the defect or characteristics of the tissue that needs to be replaced. Facial wounds or reconstruction sites can be subject to contamination, thereby risking infection of any implanted material even under ideal circumstances. Particular areas of concern are sites where minimizing the bacterial contamination prior to placing an implant is difficult (eg, the oral cavity and internal nose). Reconstruction involves the facial subcutaneous soft tissue and/or bone, and the ideal implant provides support and natural feel, as well as a low risk of infection. The biocompatibility of alloplastic implants depends on the tissue inertness of the implant and the porosity, allowing connective tissue ingrowth, which in turn decreases the susceptibility to infection. Scalafani et al demonstrated that alloplastic implants contaminated prior to fibrovascular ingrowth had a much higher incidence of infection and rejection. To examine the effectiveness of several techniques for infiltrating antibiotics into alloplastic implants of different porosity using 2 commonly used alloplastic implants, expanded polytetrafluoroethylene (e-PTFE, or GORE-TEX) and porous high-density polyethylene (Medpor). Using an in vitro bacterial growth inhibition model, we found that suction infiltration of the implant with antibiotics was the most effective technique, with a statistically significant advantage over other techniques used. The advantages of the suction impregnation were seen to be most effective using alloplasts with a smaller pore size (20-30 microm) (P < .001), but there was a statistically significant difference even with implants with a larger pore size (150-200 microm) (P < .001). Suction infiltration of antibiotics into porous implants seems to be the most effective method identified using an in vitro testing protocol. Further experiments will be needed to confirm the effectiveness in reducing the perioperative risk of infection in vivo.
Roberts, W E; Marshall, K J; Mozsary, P G
1990-01-01
A two-stage endosseous implant, placed in the retromolar area of the mandible was utilized as rigid anchorage to translate two molars 10-12 millimeters mesially into an atrophic endentulous ridge. Despite substantial anchorage demand over a three year period, the endosseous implant remained rigid ("osseointegrated"). At the end of treatment the implant and adjacent, intravitally labeled bone were recovered. Microradiographic and polarized light analyses revealed that about 80 percent of the endosseous portion of the implant was in direct contact with mature lamellar bone. Bone labels demonstrated a remarkably high remodeling rate (about 30 percent/year) for cortical bone within 0.5 millimeter of the interface. Continuous remodeling may be the long-term mechanism whereby loaded implants resist bone fatigue and maintain "osseointegration." Clinical use of orthodontic implants, placed outside the dental arches, requires careful attention to soft tissue management.
Postnov, A; Zarowski, A; De Clerck, N; Vanpoucke, F; Offeciers, F E; Van Dyck, D; Peeters, S
2006-05-01
X-ray microtomography (micro-CT) is a new technique allowing for visualization of the internal structure of opaque specimens with a quasi-histological quality. Among multiple potential applications, the use of this technique in otology is very promising. Micro-CT appears to be ideally suited for in vitro visualization of the inner ear tissues as well as for evaluation of the electrode damage and/or surgical insertion trauma during implantation of the cochlear implant electrodes. This technique can greatly aid in design and development of new cochlear implant electrodes and is applicable for temporal bone studies. The main advantage of micro-CT is the practically artefact-free preparation of the samples and the possibility of evaluation of the interesting parameters along the whole insertion depth of the electrode. This paper presents the results of the first application of micro-CT for visualization of the inner ear structures in human temporal bones and for evaluation of the surgical positioning of the cochlear implant electrodes relative to the intracochlear soft tissues.
In vitro effects of dental cements on hard and soft tissues associated with dental implants.
Rodriguez, Lucas C; Saba, Juliana N; Chung, Kwok-Hung; Wadhwani, Chandur; Rodrigues, Danieli C
2017-07-01
Dental cements for cement-retained restorations are often chosen based on clinician preference for the product's material properties, mixing process, delivery mechanism, or viscosity. The composition of dental cement may play a significant role in the proliferation or inhibition of different bacterial strains associated with peri-implant disease, and the effect of dental cements on host cellular proliferation may provide further insight into appropriate cement material selection. The purpose of this in vitro study was to investigate the cellular host response of bone cells (osteoblasts) and soft tissue cells (gingival fibroblasts) to dental cements. Zinc oxide (eugenol and noneugenol), zinc phosphate, and acrylic resin cements were molded into pellets and directly applied to confluent preosteoblast (cell line MC3T3 E1) or gingival fibroblast cell cultures (cell line HGF) to determine cellular viability after exposure. Controls were defined as confluent cell cultures with no cement exposure. Direct contact cell culture testing was conducted following International Organization for Standardization 10993 methods, and all experiments were performed in triplicate. To compare either the MC3T3 E1 cell line, or the HGF cell line alone, a 1-way ANOVA test with multiple comparisons was used (α=.05). To compare the MC3T3 E1 cell line results and the HGF cell line results, a 2-way ANOVA test with multiple comparisons was used (α=.05). The results of this study illustrated that while both bone and soft tissue cell lines were vulnerable to the dental cement test materials, the soft tissue cell line (human gingival fibroblasts) was more susceptible to reduced cellular viability after exposure. The HGF cell line was much more sensitive to cement exposure. Here, the acrylic resin, zinc oxide (eugenol), and zinc phosphate cements significantly reduced cellular viability after exposure with respect to HGF cells only. Within the limitation of this in vitro cellular study, the results indicated that cell response to various implant cements varied significantly, with osteoblast proliferation much less affected than gingival fibroblast cells. Furthermore, the zinc oxide noneugenol dental cement appeared to affect the cell lines significantly less than the other test cements. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Oshida, Yoshiki; Tuna, Elif B.; Aktören, Oya; Gençay, Koray
2010-01-01
Among various dental materials and their successful applications, a dental implant is a good example of the integrated system of science and technology involved in multiple disciplines including surface chemistry and physics, biomechanics, from macro-scale to nano-scale manufacturing technologies and surface engineering. As many other dental materials and devices, there are crucial requirements taken upon on dental implants systems, since surface of dental implants is directly in contact with vital hard/soft tissue and is subjected to chemical as well as mechanical bio-environments. Such requirements should, at least, include biological compatibility, mechanical compatibility, and morphological compatibility to surrounding vital tissues. In this review, based on carefully selected about 500 published articles, these requirements plus MRI compatibility are firstly reviewed, followed by surface texturing methods in details. Normally dental implants are placed to lost tooth/teeth location(s) in adult patients whose skeleton and bony growth have already completed. However, there are some controversial issues for placing dental implants in growing patients. This point has been, in most of dental articles, overlooked. This review, therefore, throws a deliberate sight on this point. Concluding this review, we are proposing a novel implant system that integrates materials science and up-dated surface technology to improve dental implant systems exhibiting bio- and mechano-functionalities. PMID:20480036
Yang, Sumi; Jang, LindyK; Kim, Semin; Yang, Jongcheol; Yang, Kisuk; Cho, Seung-Woo; Lee, Jae Young
2016-11-01
Electrically conductive biomaterials that can efficiently deliver electrical signals to cells or improve electrical communication among cells have received considerable attention for potential tissue engineering applications. Conductive hydrogels are desirable particularly for neural applications, as they can provide electrical signals and soft microenvironments that can mimic native nerve tissues. In this study, conductive and soft polypyrrole/alginate (PPy/Alg) hydrogels are developed by chemically polymerizing PPy within ionically cross-linked alginate hydrogel networks. The synthesized hydrogels exhibit a Young's modulus of 20-200 kPa. Electrical conductance of the PPy/Alg hydrogels could be enhanced by more than one order of magnitude compared to that of pristine alginate hydrogels. In vitro studies with human bone marrow-derived mesenchymal stem cells (hMSCs) reveal that cell adhesion and growth are promoted on the PPy/Alg hydrogels. Additionally, the PPy/Alg hydrogels support and greatly enhance the expression of neural differentiation markers (i.e., Tuj1 and MAP2) of hMSCs compared to tissue culture plate controls. Subcutaneous implantation of the hydrogels for eight weeks induces mild inflammatory reactions. These soft and conductive hydrogels will serve as a useful platform to study the effects of electrical and mechanical signals on stem cells and/or neural cells and to develop multifunctional neural tissue engineering scaffolds. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Alves, Antoine; Attik, Nina; Bayon, Yves; Royet, Elodie; Wirth, Carine; Bourges, Xavier; Piat, Alexis; Dolmazon, Gaëlle; Clermont, Gaëlle; Boutrand, Jean-Pierre; Grosgogeat, Brigitte; Gritsch, Kerstin
2018-03-14
The paradigm shift brought about by the expansion of tissue engineering and regenerative medicine away from the use of biomaterials, currently questions the value of histopathologic methods in the evaluation of biological changes. To date, the available tools of evaluation are not fully consistent and satisfactory for these advanced therapies. We have developed a new, simple and inexpensive quantitative digital approach that provides key metrics for structural and compositional characterization of the regenerated tissues. For example, metrics provide the tissue ingrowth rate (TIR) which integrates two separate indicators; the cell ingrowth rate (CIR) and the total collagen content (TCC) as featured in the equation, TIR% = CIR% + TCC%. Moreover a subset of quantitative indicators describing the directional organization of the collagen (relating structure and mechanical function of tissues), the ratio of collagen I to collagen III (remodeling quality) and the optical anisotropy property of the collagen (maturity indicator) was automatically assessed as well. Using an image analyzer, all metrics were extracted from only two serial sections stained with either Feulgen & Rossenbeck (cell specific) or Picrosirius Red F3BA (collagen specific). To validate this new procedure, three-dimensional (3D) scaffolds were intraperitoneally implanted in healthy and in diabetic rats. It was hypothesized that quantitatively, the healing tissue would be significantly delayed and of poor quality in diabetic rats in comparison to healthy rats. In addition, a chemically modified 3D scaffold was similarly implanted in a third group of healthy rats with the assumption that modulation of the ingrown tissue would be quantitatively present in comparison to the 3D scaffold-healthy group. After 21 days of implantation, both hypotheses were verified by use of this novel computerized approach. When the two methods were run in parallel, the quantitative results revealed fine details and differences not detected by the semi-quantitative assessment, demonstrating the importance of quantitative analysis in the performance evaluation of soft tissue healing. This automated and supervised method reduced operator dependency and proved to be simple, sensitive, cost-effective and time-effective. It supports objective therapeutic comparisons and helps to elucidate regeneration and the dynamics of a functional tissue.
Kinneberg, Kirsten R. C.; Galloway, Marc T.; Butler, David L.; Shearn, Jason T.
2011-01-01
Previous studies by our laboratory have demonstrated that implanting a stiffer tissue engineered construct at surgery is positively correlated with repair tissue stiffness at 12 weeks. The objective of this study was to test this correlation by implanting a construct that matches normal tissue biomechanical properties. To do this, we utilized a soft tissue patellar tendon autograft to repair a central-third patellar tendon defect. Patellar tendon auto-graft repairs were contrasted against an unfilled defect repaired by natural healing (NH). We hypothesized that after 12 weeks, patellar tendon autograft repairs would have biomechanical properties superior to NH. Bilateral defects were established in the central-third patellar tendon of skeletally mature (one year old), female New Zealand White rabbits (n = 10). In one limb, the excised tissue, the patellar tendon autograft, was sutured into the defect site. In the contralateral limb, the defect was left empty (natural healing). After 12 weeks of recovery, the animals were euthanized and their limbs were dedicated to bio-mechanical (n = 7) or histological (n = 3) evaluations. Only stiffness was improved by treatment with patellar tendon autograft relative to natural healing (p = 0.009). Additionally, neither the patellar tendon autograft nor natural healing repairs regenerated a normal zonal insertion site between the tendon and bone. Immunohistochemical staining for collagen type II demonstrated that fibrocartilage-like tissue was regenerated at the tendon-bone interface for both repairs. However, the tissue was disorganized. Insufficient tissue integration at the tendon-to-bone junction led to repair tissue failure at the insertion site during testing. It is important to re-establish the tendon-to-bone insertion site because it provides joint stability and enables force transmission from muscle to tendon and subsequent loading of the tendon. Without loading, tendon mechanical properties deteriorate. Future studies by our laboratory will investigate potential strategies to improve patellar tendon autograft integration into bone using this model. [DOI: 10.1115/1.4004948] PMID:22010737
A technique for transferring a patient's smile line to a cone beam computed tomography (CBCT) image.
Bidra, Avinash S
2014-08-01
Fixed implant-supported prosthodontic treatment for patients requiring a gingival prosthesis often demands that bone and implant levels be apical to the patient's maximum smile line. This is to avoid the display of the prosthesis-tissue junction (the junction between the gingival prosthesis and natural soft tissues) and prevent esthetic failures. Recording a patient's lip position during maximum smile is invaluable for the treatment planning process. This article presents a simple technique for clinically recording and transferring the patient's maximum smile line to cone beam computed tomography (CBCT) images for analysis. The technique can help clinicians accurately determine the need for and amount of bone reduction required with respect to the maximum smile line and place implants in optimal positions. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Papadakis, Marios; Rahmanian-Schwarz, Afshin; Bednarek, Marzena; Arafkas, Mohamed; Holschneider, Philipp; Hübner, Gunnar
2017-05-15
Accidental extravasation is a serious iatrogenic injury among patients receiving anthracycline-containing chemotherapy. The aim of this work is to present a combination therapy for chest wall reconstruction following epirubicin extravasation. Herein, we report a 68-year-old woman with massive soft tissue necrosis of the anterolateral chest wall after epirubicin extravasation from a port implanted in the subclavicular area. The necrotic tissue was resected, the port was removed, and negative-pressure wound therapy was applied. Three weeks later, a latissimus dorsi pedicle flap was successfully used to cover the defect. To the best of the authors' knowledge, this is the first report of a strategy comprising the combination of negative-pressure wound therapy and a latissimus pedicle flap for reconstruction of the chest wall after soft tissue necrosis following epirubicin extravasation.
Linsheng, Li; Guoxiang, Lin; Lihui, Li
2016-08-12
In this paper, magnesium matrix hydroxyapatite composite material was prepared by electrophoretic deposition method. The optimal process parameters of electrophoretic deposition were HA suspension concentration of 0.02 kg/L, aging time of 10 days and voltage of 60 V. Animal experiment and SBF immersion experiment were used to test the biocompatibility and bioactivity of this material respectively. The SD rats were divided into control group and implant group. The implant surrounding tissue was taken to do tissue biopsy, HE dyed and organizational analysis after a certain amount of time in the SD rat body. The biological composite material was soaked in SBF solution under homeothermic condition. After 40 days, the bioactivity of the biological composite material was evaluated by testing the growth ability of apatite on composite material. The experiment results showed that magnesium matrix hydroxyapatite biological composite material was successfully prepared by electrophoretic deposition method. Tissue hyperplasia, connective tissue and new blood vessels appeared in the implant surrounding soft tissue. No infiltration of inflammatory cells of lymphocytes and megakaryocytes around the implant was found. After soaked in SBF solution, a layer bone-like apatite was found on the surface of magnesium matrix hydroxyapatite biological composite material. The magnesium matrix hydroxyapatite biological composite material could promot calcium deposition and induce bone-like apatite formation with no cytotoxicity and good biocompatibility and bioactivity.
[Breast reconstruction: autologous tissue versus implant].
Plogmeier, K; Handstein, S; Schneider, W
1998-01-01
Modified radical mastectomy remains the standard for treatment of breast cancer. Women faced with the diagnosis of breast cancer often find it difficult to cope with the arousing emotions. Fear of death or cancer recurrence and a perceived loss of femininity often coexists with the desire for a return to normality and wholeness. For women seeking breast reconstruction various techniques have been developed. Two different ways for breast reconstruction have become a standard. One way is the reconstruction by tissue expansion or transposing locally available tissue with the use of implants. The other way is the reconstruction of the breast without using any implants with the Latissimus dorsi flap or the TRAM flap. We performed 291 breast reconstructions. In 125 women available tissue and an implant was used. The Latissimus dorsi flap was used in 57 cases and 109 TRAM flaps either pedicled or as a microvascular flap were performed. Using expanders we found a perforation of the device in 2 cases. After using implants there were capsular contracture in 2 cases and in 1 case we had an infection. Using autologous tissue we had 2 partial flap necrosis, 4 hematomas, and 4 prolonged healings. There was no complete flap necrosis. Breast reconstruction using autologous tissue i.e. the TRAM flap is supposed to be a standard technique. Microsurgical transplantation of the TRAM flap shows almost no morbidity of the donor site area. Autologous tissue follows the changes of the body like weight gain or reduction to a certain extend and shows neither capsular contracture nor other implant associated side effects. Women get the impression that the TRAM flap is like soft tissue to the touch and not like a foreign body. The aesthetic results were in all cases superior sometimes needing minor secondary correction and mostly shaping of the nippel-areola complex. All patients were pleased with the result.
Sanz, Mariano; Simion, Massimo
2014-04-01
The scope was to review the three main clinical indications in periodontal plastic surgical procedures. To review the fundamental principles in periodontal plastic surgery, the main surgical designs in flap surgery applied to the treatment of recessions, peri-implant soft tissue deficiencies and soft tissue ridge augmentation, as well as the surgical principles of using autologous connective tissue grafts and soft tissue substitutes. In the pre-operative phase, the key elements are the control of prognostic factors affecting the patient, namely oral hygiene, tobacco smoking cessation and systemic disease control. In the operative phase, the principles of flap design, mobilization, advancement, adaptation and stabilization. In the post-operative phase infection control, including effective oral hygiene measures, antiseptic treatment and other medications. In single recession defects, the most widely used flap technique is the coronally advanced flap and in specific clinical situations the laterally positioned flap. In multiple recession defects, the number of defects and their location and depth guide the surgical design, being one design with and the other without vertical releasing incisions. When flaps are used in combination with grafts the tunnel flap is also used extensively. The key elements are the donor site selection and harvesting technique, its tissue integration and volume stability. Given the current evidence, various clinical recommendations on the use of flaps and grafts are provided. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Localizing and Assessing Amputee Pain with Intense Focused Ultrasound
2016-10-01
the nerve and then implants it into nearby muscle. TMR surgery has anecdotal evidence of reduced pain for amputees relative to standard amputee...Neuropathic Pain Is Present in Chronic Low Back Pain and Soft Tissue Syndromes? An Evidence - Based Structured Review. Pain Med. 2014 Jan 1;15(1):4–15...scar tissue at the end of cut nerves that then applies pressure to the nerve ending. In addition, traditional amputation surgery almost always produces
Reliability of Soft Tissue Model Based Implant Surgical Guides; A Methodological Mistake.
Sabour, Siamak; Dastjerdi, Elahe Vahid
2012-08-20
Abstract We were interested to read the paper by Maney P and colleagues published in the July 2012 issue of J Oral Implantol. The authors aimed to assess the reliability of soft tissue model based implant surgical guides reported that the accuracy was evaluated using software. 1 I found the manuscript title of Maney P, et al. incorrect and misleading. Moreover, they reported twenty-two sites (46.81%) were considered accurate (13 of 24 maxillary and 9 of 23 mandibular sites). As the authors point out in their conclusion, Soft tissue models do not always provide sufficient accuracy for implant surgical guide fabrication.Reliability (precision) and validity (accuracy) are two different methodological issues in researches. Sensitivity, specificity, PPV, NPV, likelihood ratio positive (true positive/false negative) and likelihood ratio negative (false positive/ true negative) as well as odds ratio (true results\\false results - preferably more than 50) are among the tests to evaluate the validity (accuracy) of a single test compared to a gold standard.2-4 It is not clear that the reported twenty-two sites (46.81%) which were considered accurate related to which of the above mentioned estimates for validity analysis. Reliability (repeatability or reproducibility) is being assessed by different statistical tests such as Pearson r, least square and paired t.test which all of them are among common mistakes in reliability analysis 5. Briefly, for quantitative variable Intra Class Correlation Coefficient (ICC) and for qualitative variables weighted kappa should be used with caution because kappa has its own limitation too. Regarding reliability or agreement, it is good to know that for computing kappa value, just concordant cells are being considered, whereas discordant cells should also be taking into account in order to reach a correct estimation of agreement (Weighted kappa).2-4 As a take home message, for reliability and validity analysis, appropriate tests should be applied.
Aissa, J; Thomas, C; Sawicki, L M; Caspers, J; Kröpil, P; Antoch, G; Boos, J
2017-05-01
To investigate the value of dedicated computed tomography (CT) iterative metal artefact reduction (iMAR) algorithms in patients after spinal instrumentation. Post-surgical spinal CT images of 24 patients performed between March 2015 and July 2016 were retrospectively included. Images were reconstructed with standard weighted filtered back projection (WFBP) and with two dedicated iMAR algorithms (iMAR-Algo1, adjusted to spinal instrumentations and iMAR-Algo2, adjusted to large metallic hip implants) using a medium smooth kernel (B30f) and a sharp kernel (B70f). Frequencies of density changes were quantified to assess objective image quality. Image quality was rated subjectively by evaluating the visibility of critical anatomical structures including the central canal, the spinal cord, neural foramina, and vertebral bone. Both iMAR algorithms significantly reduced artefacts from metal compared with WFBP (p<0.0001). Results of subjective image analysis showed that both iMAR algorithms led to an improvement in visualisation of soft-tissue structures (median iMAR-Algo1=3; interquartile range [IQR]:1.5-3; iMAR-Algo2=4; IQR: 3.5-4) and bone structures (iMAR-Algo1=3; IQR:3-4; iMAR-Algo2=4; IQR:4-5) compared to WFBP (soft tissue: median 2; IQR: 0.5-2 and bone structures: median 2; IQR: 1-3; p<0.0001). Compared with iMAR-Algo1, objective artefact reduction and subjective visualisation of soft-tissue and bone structures were improved with iMAR-Algo2 (p<0.0001). Both iMAR algorithms reduced artefacts compared with WFBP, however, the iMAR algorithm with dedicated settings for large metallic implants was superior to the algorithm specifically adjusted to spinal implants. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Proussaefs, Periklis
2016-11-01
This article describes a technique in which a custom-made computer-aided design and computer-aided manufacturing (CAD-CAM) healing abutment milled from a poly(methyl methacrylate) (PMMA) block is fabricated and bonded to a titanium metal insert. An impression is made during dental implant surgery, and the CAD-CAM custom-made healing abutment is fabricated before second-stage surgery while appropriate healing time is allowed for the dental implant to osseointegrate. The contours of the healing abutment are based on the contours of a tentatively designed definitive prosthesis. The healing tissue obtains contours that will be compatible with the contours of the definitive prosthesis. After the milling process is complete, a titanium metal insert is bonded to the healing abutment. Placement of the custom-made CAD-CAM healing abutment at second-stage surgery allows the tissue to obtain contours similar to those of the definitive prosthesis. A custom-made CAD-CAM impression coping milled from a PMMA block and with a titanium insert is used for the definitive impression after the soft tissue has healed. This technique allows guided soft tissue healing by using a custom-made CAD-CAM healing abutment and impression coping. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
The role of hinges in primary total knee replacement.
Gehrke, T; Kendoff, D; Haasper, C
2014-11-01
The use of hinged implants in primary total knee replacement (TKR) should be restricted to selected indications and mainly for elderly patients. Potential indications for a rotating hinge or pure hinge implant in primary TKR include: collateral ligament insufficiency, severe varus or valgus deformity (>20°) with necessary relevant soft-tissue release, relevant bone loss including insertions of collateral ligaments, gross flexion-extension gap imbalance, ankylosis, or hyperlaxity. Although data reported in the literature are inconsistent, clinical results depend on implant design, proper technical use, and adequate indications. We present our experience with a specific implant type that we have used for over 30 years and which has given our elderly patients good mid-term results. Because revision of implants with long cemented stems can be very challenging, an effort should be made in the future to use shorter stems in modular versions of hinged implants. ©2014 The British Editorial Society of Bone & Joint Surgery.
Nasal Floor Augmentation for the Reconstruction of the Atrophic Maxilla: A Case Series
El-Ghareeb, Moustafa; Pi-Anfruns, Joan; Khosousi, Mohammed; Aghaloo, Tara; Moy, Peter
2012-01-01
Purpose The severely atrophic edentulous maxilla imposes a challenge for dental implant rehabilitation. Nasal floor augmentation (NFA) is a method of augmenting bone height in the anterior maxilla. Autogenous bone has been commonly used as a graft material. Because of variations in results and lack of insufficient studies reporting the use of bone substitutes to graft the nasal floor, this study aims to evaluate the survival and success of dental implants placed in nasally grafted maxillae with osteoconductive bone substitutes. Materials and Methods Six patients with completely edentulous maxillae and inadequate height in the anterior to support implants underwent NFA. The nasal floor was exposed through an intraoral approach and grafted with osteoconductive bone graft substitutes. Twenty-four dental implants were placed, restored with a bar-retained implant-supported overdenture after a traditional healing period, and followed up after prosthetic loading. Patient satisfaction was evaluated with a questionnaire, and responses were expressed on a visual analog scale from 1 to 10. Bone levels were quantified radiographically based on a score ranging from 1 to 3, where 3 represented the highest bone support. Implants were evaluated for thread exposure and soft tissue health and were considered successful if the following criteria were met: absence of mobility; lack of symptoms; bone score of 3; and healthy peri-implant soft tissue without thread exposure. Results The age of patients ranged from 48 to 84 years, with a mean of 71.2 years. Three patients underwent NFA and simultaneous implant placement, whereas the other 3 had a mean healing period of 6.5 months before implant placement. Post-loading follow-up ranged from 4 to 29 months, with a mean of 14.2 months. The implant survival rate was 100%, with no complications. Ninety-three percent of the responses to the treatment satisfaction questionnaire had a score of 7 or greater. Bone scores ranged from 2 to 3, with 87.5% of implants having a score of 3 and 12.5% having a score of 2. None of the implants had a bone score of 1. Conclusions The use of osteoconductive bone substitutes for NFA, as shown in this small case series, is a reliable method for reconstruction of the anterior atrophic maxilla for implant-supported overdentures. PMID:22177805
Jinno, T; Goldberg, V M; Davy, D; Stevenson, S
1998-10-01
The purpose of this study was to compare the osseointegration of surface-blasted Ti6A14V and CoCr implants in vivo. Ti6A14V and CoCr rods blasted with 710 microm A12O3 particles were bilaterally press-fit into the medullary space of distal femora of 24 rabbits. Evaluation was made radiographically, histologically, histomorphometrically (3, 6, and 12 weeks after implantation), and mechanically (12 weeks). Both Ti6A14V and CoCr implants demonstrated good biocompatibility radiographically and histologically. Toluidine blue-stained sections revealed an osteoconductive effect of the blasted surface, and fluorochrome labeling analysis showed active bone formation at the bone-implant interface at as late as 12 weeks for both specimens. CoCr showed significantly lower interfacial shear strength than Ti6A14V although the bone contact area with the implant surface was comparable and no intervening soft tissue at the bone-implant interface could be seen for either implant by scanning electron microscopy backscatter analysis. Unmineralized tissue (cartilage and osteoid) was observed more frequently on the CoCr surface than on the Ti6A14V surface. These data show less osseointegration of CoCr implants with this blasted surface for this short period, possibly due to a slight difference in surface roughness and some negative effects of CoCr on bone attachment.
Chang, Moontaek; Wennström, Jan L
2013-05-01
The aim was to evaluate potential relationships between the implant position relative to adjacent teeth and dimensions and topography of the papillae lateral to implant-supported single-tooth restorations. A total of 32 subjects with a single implant-supported restoration in the esthetic zone of the maxilla were consecutively selected for the study. Soft and hard tissues at the proximal sites of the restoration were evaluated by the use of clinical, photographic, diagnostic cast, and radiographic assessments. A questionnaire was used for assessment of the patients' satisfaction with the esthetic outcome of the restorations. Potential factors influencing the papilla level and the presence of a complete papilla fill were investigated with generalized estimation equations (GEE) analysis. The bone level at the adjacent tooth significantly influenced the papilla level (P < 0.001). The distance between the contact point and the bone level at the adjacent tooth was significantly shorter for "complete" (4.3 mm) papillae than that for "deficient" papillae (5.7 mm) (P < 0.001). The GEE logistic model revealed that the chance of a complete papilla fill improved with increased facio-lingual thickness of the papilla (P = 0.004) and decreased distance between the contact point and the bone level at the tooth (P = 0.004). The self-reported satisfaction with the esthetic appearance of the implant-born restoration was not significantly different between patients with "complete" and "deficient" papillae. The probability of a complete papilla fill was significantly affected by the facio-lingual dimension of the papilla base and the distance between the contact point between the crowns and the bone level at the tooth. © 2012 John Wiley & Sons A/S.
Chae, Sung-Wook; Kim, Young-Sung; Lee, Yong-Moo; Kim, Won-Kyung; Lee, Young-Kyoo; Kim, Su-Hwan
2015-02-01
This study was conducted to compare the cumulative survival rates (CSRs) and the incidence of postloading complications (PLCs) between a bone-level internal connection system (ICS-BL) and an external connection system (ECS). The medical records of patients treated with either a ICS-BL or ECS between 2007 and 2010 at Asan Medical Center were reviewed. PLCs were divided into two categories: biological and technical. Biological complications included >4 mm of probing pocket depth, thread exposure in radiographs, and soft tissue complications, whereas technical complications included chipping of the veneering material, fracture of the implant, fracture of the crown, loosening or fracture of the abutment or screw, loss of retention, and loss of access hole filling material. CSRs were determined by a life-table analysis and compared using the log-rank chi-square test. The incidence of PLC was compared with the Pearson chi-squared test. A total of 2,651 implants in 1,074 patients (1,167 ICS-BLs in 551 patients and 1,484 ECSs in 523 patients) were analyzed. The average observation periods were 3.4 years for the ICS-BLs and 3.1 years for the ECSs. The six-year CSR of all implants was 96.1% (94.9% for the ICS-BLs and 97.1% for the ECSs, P=0.619). Soft tissue complications were more frequent with the ECSs (P=0.005) and loosening or fracture of the abutment or screw occurred more frequently with the ICS-BLs (P<0.001). Within the limitations of this study, the ICS-BL was more prone to technical complications while the ECS was more vulnerable to biological complications.
Verstraete, Matthias A; Meere, Patrick A; Salvadore, Gaia; Victor, Jan; Walker, Peter S
2017-06-14
Proper tension of the knee's soft tissue envelope is important during total knee arthroplasty; incorrect tensioning potentially leads to joint stiffness or instability. The latter remains an important trigger for revision surgery. The use of sensors quantifying the intra-articular loads, allows surgeons to assess the ligament tension at the time of surgery. However, realistic target values are missing. In the framework of this paper, eight non-arthritic cadaveric specimens were tested and the intra-articular loads transferred by the medial and lateral compartment were measured using custom sensor modules. These modules were inserted below the articulating surfaces of the proximal tibia, with the specimens mounted on a test setup that mimics surgical conditions. For both compartments, the highest loads are observed in full extension. While creating knee flexion by lifting the femur and flexing the hip, mean values (standard deviation) of 114N (71N) and 63N (28N) are observed at 0° flexion for the medial and lateral compartment respectively. Upon flexion, both medial and lateral loads decrease with mean values at 90° flexion of 30N (22N) and 6N (5N) respectively. The majority of the load is transmitted through the medial compartment. These observations are linked to the deformation of the medial and lateral collaterals, in addition to the anatomy of the passive soft tissues surrounding the knee. In conclusion, these findings provide tangible clinical guidance in assessing the soft tissue loads when dealing with anatomically designed total knee implants. Copyright © 2017 Elsevier Ltd. All rights reserved.
Graves, Matthew L; Porter, Scott E; Fagan, Bryan C; Brien, Glenn A; Lewis, Matthew W; Biggers, Marcus D; Woodall, James R; Russell, George V
2010-08-11
Open treatment of pilon fractures is associated with wound healing complications. A traumatized, limited soft tissue envelope contributes to wound healing complications. Obese patients have larger soft tissue envelopes around the ankle, theoretically providing a greater area for energy distribution and more accommodation to implants. This led us to test 2 hypotheses: (1) ankle dimensions in obese patients are larger than in lean patients, and (2) the increased soft tissue envelope volume translates into fewer wound complications. A consecutive series of 176 pilon fractures treated from March 2002 to December 2007 were retrospectively reviewed. Inclusion criteria were adults who received a preoperative computed tomography (CT) scan and were treated with a staged protocol including plating. Patients with body mass index (BMI) >30 were compared to those with BMI <30 for CT-derived ankle dimensions and wound complications. Comorbidities were evaluated for their role as potential confounders. Thirty-one fractures in obese patients were compared to 83 in lean patients. The average ratio of bone area to soft tissue area at the tibial plafond was 0.35 for the obese group and 0.38 for the lean group (P=.012). There were 8 major wound-healing complications. Four occurred in the obese group (incidence 13%), and 4 in the lean group (incidence 5%) (P=.252). Ankle dimensions in clinically obese patients are larger than in lean patients. Obesity does not appear to be protective of wound-healing complications, but rather there is a trend toward the opposite. Copyright 2010, SLACK Incorporated.
Noelken, Robert; Neffe, Bettina Anna; Kunkel, Martin; Wagner, Wilfried
2014-02-01
Placement of implants into extraction sockets targets the maintenance of peri-implant hard and soft tissue structures and the support of a natural and esthetic contour. The main advantages of immediate implant insertion in comparison with delayed implant placement protocols are as follows: a reduced treatment time, less number of sessions, and, thus, the less invasive procedure. This study examines the clinical performance (survival rate, marginal bone levels and Pink Esthetic Score [PES]) of OsseoSpeed implants placed into extraction sockets with immediate provisionalization in the anterior maxilla after a follow-up of at least 12 months. Twenty patients received a total number of 37 OsseoSpeed implants which were immediately inserted into extraction sockets with or without facial bone deficiencies of various dimensions. A flapless procedure was applied, and the implants were immediately provisionalized with temporary crowns without occlusal contacts. Facial gaps between implant surface and facial bone or the previous contour of the alveolar process were grafted with autogenous bone chips. Implants in diameters 3.5, 4.0, 4.5, and 5.0 with lengths of 11-17 mm were used in the study. During the course of the study, interproximal marginal bone levels, the thickness of the facial bony wall, implant success rate according to the criteria established by Buser, and the PES were assessed per implant. One patient with three implants did not continue the study after prosthesis delivery, the remaining 34 implants were still in function at the final follow-up (survival rate: 100%). The mean follow-up period was 27 months (range, 12-40 months). Marginal bone height at the level of the implant shoulder averaged -0.1 ± 0.55 mm (range, -1.25 to 1.47 mm) at the final follow-up. The mean PES ratings were 11.3 ± 1.8 (range, 6-14) at the final follow-up. In 78% of the patients, the PES was preserved or even improved. Success rates, marginal bone levels, and esthetic results suggest proof of principle for the preservation of marginal bone height at immediately placed and provisionalized OsseoSpeed implants after a follow-up of at least 12 months. Even implant sites with facial bony deficiencies can be successfully treated with a favorable esthetic outcome using the immediate implant insertion, immediate reconstruction, and immediate provisionalization technique. © 2013 John Wiley & Sons A/S.
Pektaş, Ömer; Tönük, Ergin
2014-11-01
At the interface between the jawbone and the roots of natural teeth, a thin, elastic, shock-absorbing tissue, called the periodontal ligament, forms a cushion which provides certain flexibility under mechanical loading. The dental restorations supported by implants, however, involve comparatively rigid connections to the jawbone. This causes overloading of the implant while bearing functional loading together with neighboring natural teeth, which leads to high stresses within the implant system and in the jawbone. A dental implant, with resilient components in the upper structure (abutment) in order to mimic the mechanical behavior of the periodontal ligament in the axial direction, was designed, analyzed in silico, and produced for mechanical testing. The aims of the design were avoiding high levels of stress, loosening of the abutment connection screw, and soft tissue irritations. The finite element analysis of the designed implant revealed that the elastic abutment yielded a similar axial mobility with the natural tooth while keeping stress in the implant at safe levels. The in vitro mechanical testing of the prototype resulted in similar axial mobility predicted by the analysis and as that of a typical natural tooth. The abutment screw did not loosen under repeated loading and there was no static or fatigue failure. © IMechE 2014.
NASA Astrophysics Data System (ADS)
Kim, Hyun; Shim, Bong Sup
2014-08-01
Electrogenetic tissues in human body such as central and peripheral nerve systems, muscular and cardiomuscular systems are soft and stretchable materials. However, most of the artificial materials, interfacing with those conductive tissues, such as neural electrodes and cardiac pacemakers, have stiff mechanical properties. The rather contradictory properties between natural and artificial materials usually cause critical incompatibility problems in implanting bodymachine interfaces for wide ranges of biomedical devices. Thus, we developed a stretchable and electrically conductive material with complex hierarchical structures; multi-scale microstructures and nanostructural electrical pathways. For biomedical purposes, an implantable polycaprolactone (PCL) membrane was coated by molecularly controlled layer-bylayer (LBL) assembly of single-walled carbon nanotubes (SWNTs) or poly(3,4-ethylenedioxythiophene) (PEDOT). The soft PCL membrane with asymmetric micro- and nano-pores provides elastic properties, while conductive SWNT or PEDOT coating preserves stable electrical conductivity even in a fully stretched state. This electrical conductivity enhanced ionic cell transmission and cell-to-cell interactions as well as electrical cellular stimulation on the membrane. Our novel stretchable conducting materials will overcome long-lasting challenges for bioelectronic applications by significantly reducing mechanical property gaps between tissues and artificial materials and by providing 3D interconnected electro-active pathways which can be available even at a fully stretched state.
Laranjeira, Marta S; Carvalho, Ângela; Pelaez-Vargas, Alejandro; Hansford, Derek; Ferraz, Maria Pia; Coimbra, Susana; Costa, Elísio; Santos-Silva, Alice; Fernandes, Maria Helena; Monteiro, Fernando Jorge
2014-01-01
Dental ceramic implants have shown superior esthetic behavior and the absence of induced allergic disorders when compared to titanium implants. Zirconia may become a potential candidate to be used as an alternative to titanium dental implants if surface modifications are introduced. In this work, bioactive micropatterned silica coatings were produced on zirconia substrates, using a combined methodology of sol–gel processing and soft lithography. The aim of the work was to compare the in vitro behavior of human gingival fibroblasts (HGFs) and human dermal microvascular endothelial cells (HDMECs) on three types of silica-coated zirconia surfaces: flat and micropatterned (with pillars and with parallel grooves). Our results showed that cells had a higher metabolic activity (HGF, HDMEC) and increased gene expression levels of fibroblast-specific protein-1 (FSP-1) and collagen type I (COL I) on surfaces with pillars. Nevertheless, parallel grooved surfaces were able to guide cell growth. Even capillary tube-like networks of HDMEC were oriented according to the surface geometry. Zirconia and silica with different topographies have shown to be blood compatible and silica coating reduced bacteria adhesion. All together, the results indicated that microstructured bioactive coating seems to be an efficient strategy to improve soft tissue integration on zirconia implants, protecting implants from peri-implant inflammation and improving long-term implant stabilization. This new approach of micropatterned silica coating on zirconia substrates can generate promising novel dental implants, with surfaces that provide physical cues to guide cells and enhance their behavior. PMID:27877662
NASA Astrophysics Data System (ADS)
Laranjeira, Marta S.; Carvalho, Ângela; Pelaez-Vargas, Alejandro; Hansford, Derek; Ferraz, Maria Pia; Coimbra, Susana; Costa, Elísio; Santos-Silva, Alice; Fernandes, Maria Helena; Monteiro, Fernando Jorge
2014-04-01
Dental ceramic implants have shown superior esthetic behavior and the absence of induced allergic disorders when compared to titanium implants. Zirconia may become a potential candidate to be used as an alternative to titanium dental implants if surface modifications are introduced. In this work, bioactive micropatterned silica coatings were produced on zirconia substrates, using a combined methodology of sol-gel processing and soft lithography. The aim of the work was to compare the in vitro behavior of human gingival fibroblasts (HGFs) and human dermal microvascular endothelial cells (HDMECs) on three types of silica-coated zirconia surfaces: flat and micropatterned (with pillars and with parallel grooves). Our results showed that cells had a higher metabolic activity (HGF, HDMEC) and increased gene expression levels of fibroblast-specific protein-1 (FSP-1) and collagen type I (COL I) on surfaces with pillars. Nevertheless, parallel grooved surfaces were able to guide cell growth. Even capillary tube-like networks of HDMEC were oriented according to the surface geometry. Zirconia and silica with different topographies have shown to be blood compatible and silica coating reduced bacteria adhesion. All together, the results indicated that microstructured bioactive coating seems to be an efficient strategy to improve soft tissue integration on zirconia implants, protecting implants from peri-implant inflammation and improving long-term implant stabilization. This new approach of micropatterned silica coating on zirconia substrates can generate promising novel dental implants, with surfaces that provide physical cues to guide cells and enhance their behavior.
Ueno, Takeshi; Tsukimura, Naoki; Yamada, Masahiro; Ogawa, Takahiro
2011-10-01
This study introduces nanopolymorphic features of alkali- and heat-treated titanium surfaces, comprising of tuft-like, plate-like, and nodular structures that are smaller than 100 nm and determines whether and how the addition of these nanofeatures to a microroughened titanium surface affects bone-implant integration. A comprehensive assessment of biomechanical, interfacial, and histological analyses in a rat model was performed for machined surfaces without microroughness, sandblasted-microroughened surfaces, and micro-nano hybrid surfaces created by sandblasting and alkali and heat treatment. The microroughened surface accelerated the establishment of implant biomechanical fixation at the early healing stage compared with the non-microroughened surface but did not increase the implant fixation at the late healing stage. The addition of the nanopolymorphic features to the microroughened surface further increased implant fixation throughout the healing time. The area of the new bone within 50 μm proximity of the implant surfaces, which was increased 2-3-fold using microroughened surfaces, was further increased 2-fold using nanopolymorphic surfaces. In contrast, the bone area in a 50-200 μm zone was not influenced by either microroughened or nanopolymorphic surfaces. The percentage of bone-implant contact, which was increased 4-5-fold, using microroughened surfaces, was further increased substantially by over 2-fold throughout the healing period. The percentage of soft tissue intervention between bone and implant surfaces, which was reduced to half by microroughened surfaces, was additionally reduced by the nanopolymorphic surfaces to between one-third and one-fourth, resulting in only 5-7% soft tissue intervention compared with 60-75% for the non-microroughened surface. Thus, using an exemplary alkali- and heat-treated nanopolymorphic surface, this study identified critical parameters necessary to describe the process and consequences of bone-implant integration, for which nanofeatures have specific and substantial roles beyond those of microfeatures. Nanofeature-enhanced osteoconductivity, which resulted in both the acceleration and elevation of bone-implant integration, has clearly been demonstrated. Copyright © 2011 Elsevier Ltd. All rights reserved.
Berglundh, Tord; Armitage, Gary; Araujo, Mauricio G; Avila-Ortiz, Gustavo; Blanco, Juan; Camargo, Paulo M; Chen, Stephen; Cochran, David; Derks, Jan; Figuero, Elena; Hämmerle, Christoph H F; Heitz-Mayfield, Lisa J A; Huynh-Ba, Guy; Iacono, Vincent; Koo, Ki-Tae; Lambert, France; McCauley, Laurie; Quirynen, Marc; Renvert, Stefan; Salvi, Giovanni E; Schwarz, Frank; Tarnow, Dennis; Tomasi, Cristiano; Wang, Hom-Lay; Zitzmann, Nicola
2018-06-01
A classification for peri-implant diseases and conditions was presented. Focused questions on the characteristics of peri-implant health, peri-implant mucositis, peri-implantitis, and soft- and hard-tissue deficiencies were addressed. Peri-implant health is characterized by the absence of erythema, bleeding on probing, swelling, and suppuration. It is not possible to define a range of probing depths compatible with health; Peri-implant health can exist around implants with reduced bone support. The main clinical characteristic of peri-implant mucositis is bleeding on gentle probing. Erythema, swelling, and/or suppuration may also be present. An increase in probing depth is often observed in the presence of peri-implant mucositis due to swelling or decrease in probing resistance. There is strong evidence from animal and human experimental studies that plaque is the etiological factor for peri-implant mucositis. Peri-implantitis is a plaque-associated pathological condition occurring in tissues around dental implants, characterized by inflammation in the peri-implant mucosa and subsequent progressive loss of supporting bone. Peri-implantitis sites exhibit clinical signs of inflammation, bleeding on probing, and/or suppuration, increased probing depths and/or recession of the mucosal margin in addition to radiographic bone loss. The evidence is equivocal regarding the effect of keratinized mucosa on the long-term health of the peri-implant tissue. It appears, however, that keratinized mucosa may have advantages regarding patient comfort and ease of plaque removal. Case definitions in day-to-day clinical practice and in epidemiological or disease-surveillance studies for peri-implant health, peri-implant mucositis, and peri-implantitis were introduced. The proposed case definitions should be viewed within the context that there is no generic implant and that there are numerous implant designs with different surface characteristics, surgical and loading protocols. It is recommended that the clinician obtain baseline radiographic and probing measurements following the completion of the implant-supported prosthesis. © 2018 American Academy of Periodontology and European Federation of Periodontology.
Injectable PolyMIPE Scaffolds for Soft Tissue Regeneration
Moglia, Robert S.; Robinson, Jennifer L.; Muschenborn, Andrea D.; Touchet, Tyler J.; Maitland, Duncan J.; Cosgriff-Hernandez, Elizabeth
2013-01-01
Injury caused by trauma, burns, surgery, or disease often results in soft tissue loss leading to impaired function and permanent disfiguration. Tissue engineering aims to overcome the lack of viable donor tissue by fabricating synthetic scaffolds with the requisite properties and bioactive cues to regenerate these tissues. Biomaterial scaffolds designed to match soft tissue modulus and strength should also retain the elastomeric and fatigue-resistant properties of the tissue. Of particular design importance is the interconnected porous structure of the scaffold needed to support tissue growth by facilitating mass transport. Adequate mass transport is especially true for newly implanted scaffolds that lack vasculature to provide nutrient flux. Common scaffold fabrication strategies often utilize toxic solvents and high temperatures or pressures to achieve the desired porosity. In this study, a polymerized medium internal phase emulsion (polyMIPE) is used to generate an injectable graft that cures to a porous foam at body temperature without toxic solvents. These poly(ester urethane urea) scaffolds possess elastomeric properties with tunable compressive moduli (20–200 kPa) and strengths (4–60 kPa) as well as high recovery after the first conditioning cycle (97–99%). The resultant pore architecture was highly interconnected with large voids (0.5–2 mm) from carbon dioxide generation surrounded by water-templated pores (50–300 μm). The ability to modulate both scaffold pore architecture and mechanical properties by altering emulsion chemistry was demonstrated. Permeability and form factor were experimentally measured to determine the effects of polyMIPE composition on pore interconnectivity. Finally, initial human mesenchymal stem cell (hMSC) cytocompatibility testing supported the use of these candidate scaffolds in regenerative applications. Overall, these injectable polyMIPE foams show strong promise as a biomaterial scaffold for soft tissue repair. PMID:24563552
Raman-based imaging uncovers the effects of alginate hydrogel implants in spinal cord injury
NASA Astrophysics Data System (ADS)
Galli, Roberta; Tamosaityte, Sandra; Koch, Maria; Sitoci-Ficici, Kerim H.; Later, Robert; Uckermann, Ortrud; Beiermeister, Rudolf; Gelinsky, Michael; Schackert, Gabriele; Kirsch, Matthias; Koch, Edmund; Steiner, Gerald
2015-07-01
The treatment of spinal cord injury by using implants that provide a permissive environment for axonal growth is in the focus of the research for regenerative therapies. Here, Raman-based label-free techniques were applied for the characterization of morphochemical properties of surgically induced spinal cord injury in the rat that received an implant of soft unfunctionalized alginate hydrogel. Raman microspectroscopy followed by chemometrics allowed mapping the different degenerative areas, while multimodal multiphoton microscopy (e.g. the combination of coherent anti-Stokes Raman scattering (CARS), endogenous two-photon fluorescence and second harmonic generation on the same platform) enabled to address the morphochemistry of the tissue at cellular level. The regions of injury, characterized by demyelination and scarring, were retrieved and the distribution of key tissue components was evaluated by Raman mapping. The alginate hydrogel was detected in the lesion up to six months after implantation and had positive effects on the nervous tissue. For instance, multimodal multiphoton microscopy complemented the results of Raman mapping, providing the micromorphology of lipid-rich tissue structures by CARS and enabling to discern lipid-rich regions that contained myelinated axons from degenerative regions characterized by myelin fragmentation and presence of foam cells. These findings demonstrate that Raman-based imaging methods provide useful information for the evaluation of alginate implant effects and have therefore the potential to contribute to new strategies for monitoring degenerative and regenerative processes induced in SCI, thereby improving the effectiveness of therapies.
Favia, G; Mariggio, M A; Maiorano, F; Cassano, A; Capodiferro, S; Ribatti, D
2008-01-01
In this study we investigated the property of a new medical substance, in the form of a gel compound containing four aminoacids (glycine, leucine, proline, lysine) and sodium hyaluronate (AMINOGAM), to accelerate the wound healing process of the soft oral tissues and to promote angiogenesis in vivo in the vascular proliferation in chick embryo chorioallantoic membrane (CAM) assay. Furthermore, we investigated the capacity of AMINOGAM to induce the expression of an angiogenic cytokine, namely vascular endothelial growth factor (VEGF) in human fibroblasts in vitro. Results showed that AMINOGAM promoted wound healing in post-surgical wounds (after teeth extraction, oral laser surgery with secondary healing without direct suture of the surgical wound, and after dental implant insertion). Stimulated angiogenesis in vivo in the CAM assay and the response was similar to that obtained with vascular endothelial growth factor, a well-known angiogenic cytokine, tested in the same assay, and confirmed by clinical outcomes, which showed reduction of the healing time of oral soft tissues after three different kinds of surgery and also the absence of post-operative infections.
Minimally invasive esthetic ridge preservation with growth-factor enhanced bone matrix.
Nevins, Marc L; Said, Sherif
2017-12-28
Extraction socket preservation procedures are critical to successful esthetic implant therapy. Conventional surgical approaches are technique sensitive and often result in alteration of the soft tissue architecture, which then requires additional corrective surgical procedures. This case series report presents the ability of flapless surgical techniques combined with a growth factor-enhanced bone matrix to provide esthetic ridge preservation at the time of extraction for compromised sockets. When considering esthetic dental implant therapy, preservation, or further enhancement of the available tissue support at the time of tooth extraction may provide an improved esthetic outcome with reduced postoperative sequelae and decreased treatment duration. Advances in minimally invasive surgical techniques combined with recombinant growth factor technology offer an alternative for bone reconstruction while maintaining the gingival architecture for enhanced esthetic outcome. The combination of freeze-dried bone allograft (FDBA) and rhPDGF-BB (platelet-derived growth factor-BB) provides a growth-factor enhanced matrix to induce bone and soft tissue healing. The use of a growth-factor enhanced matrix is an option for minimally invasive ridge preservation procedures for sites with advanced bone loss. Further studies including randomized clinical trials are needed to better understand the extent and limits of these procedures. The use of minimally invasive techniques with growth factors for esthetic ridge preservation reduces patient morbidity associated with more invasive approaches and increases the predictability for enhanced patient outcomes. By reducing the need for autogenous bone grafts the use of this technology is favorable for patient acceptance and ease of treatment process for esthetic dental implant therapy. © 2017 Wiley Periodicals, Inc.
Prefabricated microvascular autograft in tracheal reconstruction.
Fayad, J; Kuriloff, D B
1994-10-01
Tracheal reconstruction continues to be a challenge in head and neck surgery. Numerous techniques, including the use of alloplasts, composite grafts, and staged laryngotracheal troughs, have met with limited success because of implant exposure, infection, persistent granulation tissue, and eventual restenosis. With recently introduced techniques for soft-tissue molding, bone induction with bone morphogenetic protein, and microvascular free tissue transfer, a rodent model was developed to create a well-vascularized tracheal autograft. In this model, a rigid tube having the same dimensions and flexibility as the native trachea was created by wrapping a cylindrical silicone tracheal mold with a layer of vascularized adductor thigh muscle pedicled on the femoral vessels in the groin. Tracheal rings were created by filing transverse troughs in the muscle bed with bone morphogenetic protein-primed demineralized bone matrix before wrapping around the silicone mold. Grafts harvested at 2 weeks demonstrated rigid skeletal support provided by heterotopic bone formation in the form of rings and a smooth inner lining produced by fibroplasia. Bone transformation was controlled and restricted to the muscle troughs, allowing intervening regions of soft tissue and thus producing a flexible neotrachia. With this model, a homologous, vascularized tracheal autograft capable of microvascular free tissue transfer was fabricated based on the femoral vessels. Prefabrication of composite grafts, through the use of soft-tissue molding, bone induction, and subsequent free tissue transfer, has an unlimited potential for use in head and neck reconstruction.
Chiantella, Giovanni Carlo
2016-01-01
The present article describes the treatment given to a patient who underwent horizontal ridge augmentation surgery in the maxillary anterior area due to the premature loss of the maxillary central incisors. The complete dehiscence of the buccal plate was detected after elevation of mucoperiosteal flaps. The lesion was overfilled with deproteinized bovine xenograft particles combined with recombinant human platelet-derived growth factor BB (rhPDGF-BB) and covered with a porcine collagen barrier hydrated with the same growth factor. The soft tissues healed with no adverse complications. After 12 months, reentry surgery was carried out to place endosseous implants. Complete bone regeneration with the presence of bone-like tissue was observed. Cross-sectional computed tomography scan images confirmed integration of the bone graft and reconstruction of the lost hard tissue volume. The implants were inserted in an optimal three-dimensional position, thus facilitating esthetic restoration. Two years after insertion of final crowns, cone beam computed tomography scans displayed the stability of regenerated hard tissues around the implants. Controlled clinical studies are necessary to determine the benefit of hydrating bovine bone particles and collagen barriers with rhPDGF-BB for predictable bone regeneration of horizontal lesions.
Mechanical biocompatibility of highly deformable biomedical materials.
Mazza, Edoardo; Ehret, Alexander E
2015-08-01
Mismatch of mechanical properties between highly deformable biomedical materials and adjacent native tissue might lead to short and long term health impairment. The capability of implants to deform at the right level, i.e. similar to the macroscopic mechanical response of the surrounding biological materials, is often associated with dissimilar microstructural deformation mechanisms. This mismatch on smaller length scales might lead to micro-injuries, cell damage, inflammation, fibrosis or necrosis. Hence, the mechanical biocompatibility of soft implants depends not only on the properties and composition of the implant material, but also on its organization, distribution and motion at one or several length scales. The challenges related to the analysis and attainment of mechanical biocompatibility are illustrated with two examples: prosthetic meshes for hernia and pelvic repair and electrospun scaffolds for tissue engineering. For these material systems we describe existing methods for characterization and analysis of the non-linear response to uniaxial and multiaxial stress states, its time and history dependence, and the changes in deformation behavior associated with tissue in-growth and material resorption. We discuss the multi-scale deformation behavior of biomaterials and adjacent tissue, and indicate major interdisciplinary questions to be addressed in future research. Copyright © 2015 Elsevier Ltd. All rights reserved.
Gibon, Emmanuel; Córdova, Luis A.; Lu, Laura; Lin, Tzu-Hua; Yao, Zhenyu; Hamadouche, Moussa; Goodman, Stuart B.
2017-01-01
Novel evidence-based prosthetic designs and biomaterials facilitate the performance of highly successful joint replacement (JR) procedures. To achieve this goal, constructs must be durable, biomechanically sound, and avoid adverse local tissue reactions. Different biomaterials such as metals and their alloys, polymers, ceramics, and composites are currently used for JR implants. This review focuses on (1) the biological response to the different biomaterials used for TJR and (2) the chronic inflammatory and foreign-body response induced by byproducts of these biomaterials. A homeostatic state of bone and surrounding soft tissue with current biomaterials for JR can be achieved with mechanically stable, infection free and intact (as opposed to the release of particulate or ionic byproducts) implants. Adverse local tissue reactions (an acute/chronic inflammatory reaction, periprosthetic osteolysis, loosening and subsequent mechanical failure) may evolve when the latter conditions are not met. This article (Part 2 of 2) summarizes the biological response to the non-metallic materials commonly used for joint replacement including polyethylene, ceramics, and polymethylmethacrylate (PMMA), as well as the foreign body reaction to byproducts of these materials. PMID:27080740
Lyophilized Silk Sponges: A Versatile Biomaterial Platform for Soft Tissue Engineering
2015-01-01
We present a silk biomaterial platform with highly tunable mechanical and degradation properties for engineering and regeneration of soft tissues such as, skin, adipose, and neural tissue, with elasticity properties in the kilopascal range. Lyophilized silk sponges were prepared under different process conditions and the effect of silk molecular weight, concentration and crystallinity on 3D scaffold formation, structural integrity, morphology, mechanical and degradation properties, and cell interactions in vitro and in vivo were studied. Tuning the molecular weight distribution (via degumming time) of silk allowed the formation of stable, highly porous, 3D scaffolds that held form with silk concentrations as low as 0.5% wt/v. Mechanical properties were a function of silk concentration and scaffold degradation was driven by beta-sheet content. Lyophilized silk sponges supported the adhesion of mesenchymal stem cells throughout 3D scaffolds, cell proliferation in vitro, and cell infiltration and scaffold remodeling when implanted subcutaneously in vivo. PMID:25984573
Mimicking biological stress-strain behaviour with synthetic elastomers
NASA Astrophysics Data System (ADS)
Vatankhah-Varnosfaderani, Mohammad; Daniel, William F. M.; Everhart, Matthew H.; Pandya, Ashish A.; Liang, Heyi; Matyjaszewski, Krzysztof; Dobrynin, Andrey V.; Sheiko, Sergei S.
2017-09-01
Despite the versatility of synthetic chemistry, certain combinations of mechanical softness, strength, and toughness can be difficult to achieve in a single material. These combinations are, however, commonplace in biological tissues, and are therefore needed for applications such as medical implants, tissue engineering, soft robotics, and wearable electronics. Present materials synthesis strategies are predominantly Edisonian, involving the empirical mixing of assorted monomers, crosslinking schemes, and occluded swelling agents, but this approach yields limited property control. Here we present a general strategy for mimicking the mechanical behaviour of biological materials by precisely encoding their stress-strain curves in solvent-free brush- and comb-like polymer networks (elastomers). The code consists of three independent architectural parameters—network strand length, side-chain length and grafting density. Using prototypical poly(dimethylsiloxane) elastomers, we illustrate how this parametric triplet enables the replication of the strain-stiffening characteristics of jellyfish, lung, and arterial tissues.
Delgado-Ruiz, Rafael Arcesio; Calvo-Guirado, Jose Luis; Abboud, Marcus; Ramirez-Fernandez, Maria Piedad; Maté-Sánchez de Val, José Eduardo; Negri, Bruno; Gomez-Moreno, Gerardo; Markovic, Aleksa
2015-08-01
To describe contact, thickness, density, and orientation of connective tissue fibers around healing abutments of different geometries by means of a new method using coordinates. Following the bilateral extraction of mandibular premolars (P2, P3, and P4) from six fox hound dogs and a 2-month healing period, 36 titanium implants were inserted, onto which two groups of healing abutments of different geometry were screwed: Group A (concave abutments) and Group B (wider healing abutment). After 3 months the animals were sacrificed and samples extracted containing each implant and surrounding soft and hard tissues. Histological analysis was performed without decalcifying the samples by means of circularly polarized light under optical microscope and a system of vertical and horizontal coordinates across all the connective tissue in an area delimited by the implant/abutment, epithelium, and bone tissue. In no case had the connective tissue formed a connection to the healing abutment/implant in the internal zone; a space of 35 ± 10 μm separated the connective tissue fibers from the healing abutment surface. The total thickness of connective tissue in the horizontal direction was significantly greater in the medial zone in Group B than in Group A (p < .05). The orientation of the fibers varied according to the coordinate area so that internal coordinates showed a higher percentage of parallel fibers in Group A (p < .05) and a higher percentage of oblique fibers in Group B (p < .05); medial coordinates showed more oblique fibers (p < .05); and the area of external coordinates showed the highest percentage of perpendicular fibers (p < .05). The fiber density was higher in the basal and medial areas (p < .05). Abutment geometry influences the orientation of collagen fibers; therefore, an abutment with a profile wider than the implant platform favors oblique and perpendicular orientation of collagen fibers and greater connective tissue thickness. © 2013 Wiley Periodicals, Inc.
Histologic Evaluation of a Polylactic Acid Confluent Sheet in the Treatment of Osseous Defects,
1992-01-01
Cobb, DDS, PhD * John C. Reed, DDS + Caesar E. Solano, DMD + W. Robert Hiatt, DDS + • Departments of Periodontics and Oral Biology, University of...may be employed as a matrix for osseous grafting, for the occlusion of large bony defects, for soft tissue contour defects, and also as a bone plating...trabecular bone. Further, the periosteum regenerated as a confluent layer of fibrous connective tissue covering the superior aspect of the implant material
Effects of Skin Thickness on Cochlear Input Signal using Transcutaneous Bone Conduction Implants
Mattingly, Jameson K.; Greene, Nathaniel T.; Jenkins, Herman A.; Tollin, Daniel J.; Easter, James R.; Cass, Stephen P.
2015-01-01
Hypothesis Intracochlear sound pressures (PIC) and velocity measurements of the stapes, round window, and promontory (VStap/RW/Prom) will show frequency dependent attenuation using magnet-based, transcutaneous bone-conduction implants (TCBCI) in comparison to direct-connect, skin-penetrating implants (DCBCI). Background TCBCIs have recently been introduced as alternatives to DCBCIs. Clinical studies have demonstrated elevated high-frequency thresholds for TCBCIs as compared to DCBCIs; however, little data exists examining the direct effect of skin thickness on the cochlear input signal using TCBCIs. Methods Using seven cadveric heads, PIC was measured in the scala vestibuli and tympani with fiber-optic pressure sensors concurrently with VStap/RW/Prom via laser Doppler vibrometry. Ipsilateral titanium implant fixtures were placed and connected to either a DCBCI or TCBCI. Soft tissue flaps with varying thicknesses (no flap, 3, 6, and 9 mm) were placed successively between the magnetic plate and sound processor magnet. A bone-conduction transducer coupled to custom software provided pure tone stimuli between 120 to 10240 Hz. Results Stimulation via the DCBCI produced the largest response magnitudes. The TCBCI showed similar PSV/ST and VStap/RW/Prom with no intervening flap, and a frequency-dependent, non-linear reduction of magnitude with increasing flap thickness. Phase shows a comparable dependence on transmission delay as the acoustic baseline, and the slope steepens at higher frequencies as flap thickness increases suggesting a longer group delay. Conclusions Proper soft tissue management is critical to optimize the cochlear input signal. The skin thickness related effects on cochlear response magnitudes should be taken into account when selecting patients for a TCBCI. PMID:26164446
Peñarrocha-Oltra, David; Agustín-Panadero, Rubén; Bagán, Leticia; Giménez, Beatriz; Peñarrocha, María
2014-07-01
To describe a technique for registering the positions of multiple dental implants using a system based on photogrammetry. A case is presented in which a prosthetic treatment was performed using this technique. Three Euroteknika® dental implants were placed to rehabilitate a 55-year-old male patient with right posterior maxillary edentulism. Three months later, the positions of the implants were registered using a photogrammetry-based stereo-camera (PICcamera®). After processing patient and implant data, special abutments (PICabutment®) were screwed onto each implant. The PICcamera® was then used to capture images of the implant positions, automatically taking 150 images in less than 60 seconds. From this information a file was obtained describing the relative positions - angles and distances - of each implant in vector form. Information regarding the soft tissues was obtained from an alginate impression that was cast in plaster and scanned. A Cr-Co structure was obtained using CAD/CAM, and its passive fit was verified in the patient's mouth using the Sheffield test and the screw resistance test. Twelve months after loading, peri-implant tissues were healthy and no marginal bone loss was observed. The clinical application of this new system using photogrammetry to record the position of multiple dental implants facilitated the rehabilitation of a patient with posterior maxillary edentulism by means of a prosthesis with optimal fit. The prosthetic process was accurate, fast, simple to apply and comfortable for the patient.
Calon, Tim George Ate; van Tongeren, Joost; Omar, Omar; Johansson, Martin Lars; Stokroos, Robert-Jan
2018-04-27
To study the effect of implanting the percutaneous bone-anchored hearing system (BAHS) itself and inflammation of the peri-abutment skin warrant clarification. In this study, we aimed to acquire further insight into the immune responses related to BAHS surgery and peri-implant skin inflammation. During surgery and 12 weeks post-implantation, skin biopsies were obtained. If applicable, additional biopsies were taken during cases of inflammation. The mRNA expression of IL-1β, IL-6, IL-8, TNFα, IL-17, IL-10, TGF-ß, MIP-1α, MMP-9, TIMP-1, COL1α1, VEGF-A, FGF-2 TLR-2, and TLR-4 was quantified using qRT-PCR. Thirty-five patients agreed to the surgery and 12-week biopsy. Twenty-two patients had mRNA of sufficient quality for analysis. Ten were fitted with a BAHS using the minimally invasive Ponto surgery technique. Twelve were fitted with a BAHS using the linear incision technique with soft-tissue preservation. Five biopsies were obtained during episodes of inflammation. The post-implantation mRNA expression of IL-1β (P = .002), IL-8 (P = .003), MMP9 (P = .005), TIMP-1 (P = .002), and COL1α1 (P < .001) was significantly up-regulated. IL-6 (P = .009) and FGF-2 (P = .004) mRNA expression was significantly down-regulated after implantation. Within patients, no difference between post-implantation mRNA expression (at 12 weeks) and when inflammation was observed. Between patients, the expression of IL-1β (P = .015) and IL-17 (P = .02) was higher during cases of inflammation compared with patients who had no inflammation at 12-week follow-up. As part of a randomized, prospective, clinical trial, the present study reports the molecular profile of selected cytokines in the soft tissue around BAHS. Within the limit of this study, the results showed that 12 weeks after BAHS implantation the gene expression of some inflammatory cytokines (IL-8 and IL-1β) is still relatively high compared with the baseline, steady-state, expression. The up-regulation of anabolic (COL1α1) and tissue-remodeling (MMP-9 and TIMP1) genes indicates an ongoing remodeling process after 12 weeks of implantation. The results suggest that IL-1β, IL-17, and TNF-α may be interesting markers associated with inflammation. © 2018 The Authors. Clinical Implant Dentistry and Related Research published by Wiley Periodicals, Inc.
2016-01-01
Purpose The increasing demand for esthetically pleasing results has contributed to the use of ceramics for dental implant abutments. The aim of this study was to compare the biological response of epithelial tissue cultivated on lithium disilicate (LS2) and zirconium oxide (ZrO2) ceramics. Understanding the relevant physicochemical and mechanical properties of these ceramics will help identify the optimal material for facilitating gingival wound closure. Methods Both biomaterials were prepared with 2 different surface treatments: raw and polished. Their physicochemical characteristics were analyzed by contact angle measurements, scanning white-light interferometry, and scanning electron microscopy. An organotypic culture was then performed using a chicken epithelium model to simulate peri-implant soft tissue. We measured the contact angle, hydrophobicity, and roughness of the materials as well as the tissue behavior at their surfaces (cell migration and cell adhesion). Results The best cell migration was observed on ZrO2 ceramic. Cell adhesion was also drastically lower on the polished ZrO2 ceramic than on both the raw and polished LS2. Evaluating various surface topographies of LS2 showed that increasing surface roughness improved cell adhesion, leading to an increase of up to 13%. Conclusions Our results demonstrate that a biomaterial, here LS2, can be modified using simple surface changes in order to finely modulate soft tissue adhesion. Strong adhesion at the abutment associated with weak migration assists in gingival wound healing. On the same material, polishing can reduce cell adhesion without drastically modifying cell migration. A comparison of LS2 and ZrO2 ceramic showed that LS2 was more conducive to creating varying tissue reactions. Our results can help dental surgeons to choose, especially for esthetic implant abutments, the most appropriate biomaterial as well as the most appropriate surface treatment to use in accordance with specific clinical dental applications. PMID:28050314
A Review on the Wettability of Dental Implant Surfaces II: Biological and Clinical Aspects
Gittens, Rolando A.; Scheideler, Lutz; Rupp, Frank; Hyzy, Sharon L.; Geis-Gerstorfer, Jürgen; Schwartz, Zvi; Boyan, Barbara D.
2014-01-01
Dental and orthopaedic implants have been under continuous advancement to improve their interactions with bone and ensure a successful outcome for patients. Surface characteristics such as surface topography and surface chemistry can serve as design tools to enhance the biological response around the implant, with in vitro, in vivo and clinical studies confirming their effects. However, the comprehensive design of implants to promote early and long-term osseointegration requires a better understanding of the role of surface wettability and the mechanisms by which it affects the surrounding biological environment. This review provides a general overview of the available information about the contact angle values of experimental and of marketed implant surfaces, some of the techniques used to modify surface wettability of implants, and results from in vitro and clinical studies. We aim to expand the current understanding on the role of wettability of metallic implants at their interface with blood and the biological milieu, as well as with bacteria, and hard and soft tissues. PMID:24709541
Immediate, non-submerged, root-analogue zirconia implant in single tooth replacement.
Pirker, W; Kocher, A
2008-03-01
This report demonstrates the successful clinical use of a modified root-analogue zirconia implant for immediate single tooth replacement. A right maxillary premolar was removed and a custom-made, root-analogue, roughened zirconia implant with macro-retentions in the interdental space was fabricated and placed into the extraction socket 4 days later. Four months after root implantation a composite crown was cemented. No complications occurred during the healing period. An excellent esthetic and functional result was achieved with the composite crown. No clinically noticeable bone resorption or soft-tissue recession was observed at 26 months follow up. Significant modifications such as macro-retentions seem to indicate that primary stability and excellent osseointegration of immediate root-analogue zirconia implants can be achieved, while preventing unesthetic bone resorption. The macro-retentions must be limited to the interdental space to avoid fracture of the thin buccal cortex. This successful case warrants further clinical research in well controlled trials.
Esthetics in periodontics and implantology.
Zucchelli, Giovanni; Sharma, Praveen; Mounssif, Ilham
2018-06-01
Periodontal plastic surgery comprises an increasing part of clinical periodontology. Clinical trials have traditionally used professionals to judge esthetic outcome, and few studies have addressed patient needs and requests (true end points). Development of universally accepted and validated methods for professional esthetic assessment, together with standardized questionnaires for patient-perceived outcome, may help to provide better insights into the true needs and benefits of periodontal and implant-associated plastic surgery. In this volume of Periodontology 2000, experienced researchers and clinicians from different subdisciplines of periodontology evaluate: treatment of gingival recession with or without papilla elevation; clinical crown lengthening in the natural dentition and in prosthodontic preparative treatment; periodontal regeneration around natural teeth; and soft-tissue augmentation in edentulous areas. Similarly, experts in different areas of implant science address esthetic outcomes with single and multiple implant rehabilitation, alveolar ridge preservation, implant positioning and immediate implant placement in the esthetic zone. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
[Total hip arthroplasty through anterior "minimal invasive" approach].
Moerenhout, Kevin G; Cherix, Stéphane; Rüdiger, Hannes A
2012-12-19
Total hip replacement has seen a tremendous development and has become one of the most successful surgical interventions in orthopaedics. While during the first decades of development of total hip arthroplasty the fixation of the implant into the bone was the main concern, the focus has shifted towards surgical technique and soft tissue handling. In order to avoid permanent soft tissue damage, muscular dysfunction and concerns in regards to cosmetics, minimal invasive and anatomic approaches have been developed. We here provide a short overview on various methods of total hip replacements and we describe our technique through a minimal invasive direct anterior approach. While muscle and nerve damage is minimal, this technique allows for a rapid rehabilitation and is associated with an excellent functional outcome and a minimal risk for dislocation.
NASA Astrophysics Data System (ADS)
Wiwanto, Siska; Sulistyani, Lilies Dwi; Latief, Fourier Dzar Eljabbar; Supriadi, Sugeng; Priosoeryanto, Bambang Pontjo; Latief, Benny Syariefsyah
2018-02-01
Study of biodegradations of Magnesium ECAP (Equal Channel Angular Pressing) miniplate in the osteosynthesis system has been used as a new material for plate and screw in oral and maxillofacial surgery. This miniplate and screw that were made of Magnesium ECAP were implanted in the femurs of New Zealand rabbits. The degradation process was detected through pocket gas that appeared in hard and soft tissues surrounding in the implanted miniplates and screws. From the changes on the tissues, we can assess the biodegradation process by measuring the gas pocket through micro-CT Scan. Upon the first month of study we euthanized the rabbits and made a micro-CT Scan to see how far the effect of the gas pocket was. Histological analyses were performed to investigate the local tissue response adjacent to the Magnesium ECAP miniplates. We analyzed the femur of a rabbit a month, three months, and five months after implantation. The result showed a degradation rate in the implanted Magnesium ECAP miniplate of 0.61±0.39 mm/year. Unlike the screws, miniplates have higher water content and blood flow than bone, therefore they degrade faster. This study shows promising results for further development of Magnesium ECAP and in the production of osteosynthesis material for rigid fixation in Oral and Maxillofacial skeleton.
Bressan, Eriberto; Grusovin, Maria Gabriella; D'Avenia, Ferdinando; Neumann, Konrad; Sbricoli, Luca; Luongo, Giuseppe; Esposito, Marco
To evaluate the influence of at least three abutment disconnections in conventional loaded implants against placement of a definitive abutment in immediately non-occlusal loaded implants on hard and soft tissue changes. A secondary aim was to evaluate whether the presence of less than 2 mm of keratinised mucosa is associated with increased peri-implant marginal bone loss and soft tissue recessions. Eighty patients requiring one single crown or one fixed partial prosthesis supported by a maximum of three implants were randomised, after implants were placed with more than 35 Ncm, according to a parallel group design to receive definitive abutments that were loaded immediately (definitive abutment or immediate loading group) or transmucosal abutments, which were delayed loaded after 3 months and removed at least three times: 1. At impression taking (3 months after implant placement); 2. When checking the zirconium core on titanium abutments at single crowns or the fitting the metal structure at prostheses supported by multiple implants; 3. At delivery of the definitive prostheses (repeated disconnection or conventional loading group). Patients were treated at four centres and each patient contributed to the study, with only one prosthesis followed for 3 years after initial loading. Outcome measures were: prosthesis failures, implant failures, complications, pink aesthetic score (PES), buccal recessions, patient satisfaction, peri-implant marginal bone level changes and height of the keratinised mucosa. Forty patients were randomly allocated to each group according to a parallel group design. Six patients from the definitive abutment group dropped out or died, and one left from the repeated disconnection group. One implant, from the repeated disconnection group, fractured (difference = 3%; CI 95%: -2%, 8%; P = 1). Four provisional crowns and one definitive single crown had to be remade because of poor fitting, and one definitive crown and one definitive prosthesis because of ceramic and implant fracture, respectively, in the repeated disconnection group vs one provisional prosthesis from the definitive abutment group due to frequent debondings (difference = 15%; CI 95%: 2%, 28%; P = 0.060). Five patients from the definitive abutment group and four patients from the repeated disconnection group were affected by complications (difference = 4%; CI 95%: -11%, 20%; P = 0.725). PES scores assessed at 3 years post-loading were 11.7 (standard deviation = 1.8) mm for the definitive abutment group and 11.3 (1.5) mm for the repeated abutment changes group (difference = 0.4; CI 95%: -0.4, 1.2; P = 0.315). However, there was a difference of 0.26 out of a maximum score of 2 in favour of the definitive abutment group for soft tissue contour only. Buccal recessions at 3 years post-loading amounted to -0.1 (0.8) mm for the definitive abutment group and -0.1 (1.2) mm for the repeated abutment changes group (it was actually a soft tissue gain; difference = 0.01 mm CI 95%: -0.48, 0.50; P = 0.965). All patients declared being very satisfied or satisfied with the function and aesthetics of the prostheses and said they would undergo the same procedure again, with the exception of one patient from the repeated disconnection group who was uncertain regarding function. Mean peri-implant marginal bone loss 3 years after loading was 0.07 (0.18) mm for the definitive abutment group and 0.50 (0.93) mm for the repeated abutment changes group (difference = 0.43 mm; CI 95%: 0.13, 0.74; P = 0.007). The height of keratinised mucosa at 3 years post-loading was 2.8 (1.3) mm for the definitive abutment group and 2.8 (1.6) mm for the repeated abutment changes group (difference = 0.03; CI 95%: -0.67, 0.73; P = .926). Up to 3 years after initial loading there were no statistically significant differences between the two procedures, with the exception of 0.4 mm more marginal bone loss at implants subjected to three abutment disconnections. There were no significantly increased marginal bone loss (difference = 0.1 mm, CI 95%: -0.3, 0.5, P = 0.590) or buccal recessions (difference = 0.1 mm, CI 95%: -0.4, 0.7, P = 0.674) at implants with less than 2 mm of keratinised mucosa at loading. Three-year post-loading data showed that repeated abutment disconnections significantly increased bone loss of 0.43 mm, but this difference may not be considered clinically relevant; therefore clinicians can use the procedure they find more convenient for each specific patient. Immediately non-occlusally loaded dental implants are a viable alternative to conventional loading and no increased bone loss or buccal recessions were noticed at implants with less than 2 mm of keratinised mucosa. Conflict of interest statement: This trial was partially funded by Dentsply Sirona Implants, the manufacturer of the implants and other products evaluated in this investigation. However, data belonged to the authors and by no means did the manufacturer interfere with the conduct of the trial or the publication of the results, with the exception of rejecting a proposal to change the protocol, after the trial was started, allowing the use of indexed abutments.
Athwal, Kiron K; El Daou, Hadi; Inderhaug, Eivind; Manning, William; Davies, Andrew J; Deehan, David J; Amis, Andrew A
2017-08-01
The aim of this study was to quantify the medial soft tissue contributions to stability following constrained condylar (CC) total knee arthroplasty (TKA) and determine whether a medial reconstruction could restore stability to a soft tissue-deficient, CC-TKA knee. Eight cadaveric knees were mounted in a robotic system and tested at 0°, 30°, 60°, and 90° of flexion with ±50 N anterior-posterior force, ±8 Nm varus-valgus, and ±5 Nm internal-external torque. The deep and superficial medial collateral ligaments (dMCL, sMCL) and posteromedial capsule (PMC) were transected and their relative contributions to stabilising the applied loads were quantified. After complete medial soft tissue transection, a reconstruction using a semitendinosus tendon graft was performed, and the effect on kinematic behaviour under equivocal conditions was measured. In the CC-TKA knee, the sMCL was the major medial restraint in anterior drawer, internal-external, and valgus rotation. No significant differences were found between the rotational laxities of the reconstructed knee to the pre-deficient state for the arc of motion examined. The relative contribution of the reconstruction was higher in valgus rotation at 60° than the sMCL; otherwise, the contribution of the reconstruction was similar to that of the sMCL. There is contention whether a CC-TKA can function with medial deficiency or more constraint is required. This work has shown that a CC-TKA may not provide enough stability with an absent sMCL. However, in such cases, combining the CC-TKA with a medial soft tissue reconstruction may be considered as an alternative to a hinged implant.
Nonexpansive immediate breast reconstruction using human acellular tissue matrix graft (AlloDerm).
Salzberg, C Andrew
2006-07-01
Immediate breast reconstruction has become a standard of care following mastectomy for cancer, largely due to improved esthetic and psychologic outcomes achieved with this technique. However, the current historical standards--transverse rectus abdominis myocutaneous flap reconstruction and expander--implant surgery-still have limitations as regards patient morbidity, short-term body-image improvements, and even cost. To address these shortcomings, we employ a novel concept of human tissue replacement to enhance breast shape and provide total coverage, enabling immediate mound reconstruction without the need for breast expansion prior to permanent implant placement. AlloDerm (human acellular tissue matrix) is a human-derived graft tissue with extensive experience in various settings of skin and soft tissue replacement surgery. This report describes the success using acellular tissue matrix to provide total coverage over the prosthesis in immediate reconstruction, with limited muscle dissection. In this population, 49 patients (76 breasts) successfully underwent the acellular tissue matrix-based immediate reconstruction, resulting in durable breast reconstruction with good symmetry. These findings may predict that acellular tissue matrix-supplemented immediate breast reconstruction will become a new technique for the immediate reconstruction of the postmastectomy breast.
Mechanically switchable polymer fibers for sensing in biological conditions
NASA Astrophysics Data System (ADS)
McMillan, Sean; Rader, Chris; Jorfi, Mehdi; Pickrell, Gary; Foster, E. Johan
2017-02-01
The area of in vivo sensing using optical fibers commonly uses materials such as silica and polymethyl methacrylate, both of which possess much higher modulus than human tissue. The mechanical mismatch between materials and living tissue has been seen to cause higher levels of glial encapsulation, scarring, and inflammation, leading to failure of the implanted medical device. We present the use of a fiber made from polyvinyl alcohol (PVA) for use as an implantable sensor as it is an easy to work with functionalized polymer that undergoes a transition from rigid to soft when introduced to water. This ability to switch from stiff to soft reduces the severity of the immune response. The fabricated PVA fibers labeled with fluorescein for sensing applications showed excellent response to various stimuli while exhibiting mechanical switchability. For the dry fibers, a tensile storage modulus of 4700 MPa was measured, which fell sharply to 145 MPa upon wetting. The fibers showed excellent response to changing pH levels, producing values that were detectable in a range consistent with those seen in the literature and in proposed applications. The results show that these mechanically switchable fibers are a viable option for future sensing applications.
Tracking of Drug Release and Material Fate for Naturally Derived Omega-3 Fatty Acid Biomaterials.
Faucher, Keith M; Artzi, Natalie; Beck, Moshe; Beckerman, Rita; Moodie, Geoff; Albergo, Theresa; Conroy, Suzanne; Dale, Alicia; Corbeil, Scott; Martakos, Paul; Edelman, Elazer R
2016-03-01
In vitro and in vivo studies were conducted on omega-3 fatty acid-derived biomaterials to determine their utility as an implantable material for adhesion prevention following soft tissue hernia repair and as a means to allow for the local delivery of antimicrobial or antibiofilm agents. Naturally derived biomaterials offer several advantages over synthetic materials in the field of medical device development. These advantages include enhanced biocompatibility, elimination of risks posed by the presence of toxic catalysts and chemical crosslinking agents, and derivation from renewable resources. Omega-3 fatty acids are readily available from fish and plant sources and can be used to create implantable biomaterials either as a stand-alone device or as a device coating that can be utilized in local drug delivery applications. In-depth characterization of material erosion degradation over time using non-destructive imaging and chemical characterization techniques provided mechanistic insight into material structure: function relationship. This in turn guided rational tailoring of the material based on varying fatty acid composition to control material residence time and hence drug release. These studies demonstrate the utility of omega-3 fatty acid derived biomaterials as an absorbable material for soft tissue hernia repair and drug delivery applications.
Alveolar socket preservation with demineralised bovine bone mineral and a collagen matrix
2017-01-01
Purpose The aim of the present study was to evaluate the healing of post-extraction sockets following alveolar ridge preservation clinically, radiologically, and histologically. Methods Overall, 7 extraction sockets in 7 patients were grafted with demineralised bovine bone mineral and covered with a porcine-derived non-crosslinked collagen matrix (CM). Soft tissue healing was clinically evaluated on the basis of a specific healing index. Horizontal and vertical ridge dimensional changes were assessed clinically and radiographically at baseline and 6 months after implant placement. For histological and histomorphometric analysis, bone biopsies were harvested from the augmented sites during implant surgery 6 months after the socket preservation procedure. Results Clinically, healing proceeded uneventfully in all the sockets. A trend towards reduced horizontal and vertical socket dimensions was observed from baseline to the final examination. The mean width and height of resorption were 1.21 mm (P=0.005) and 0.46 mm (P=0.004), respectively. Histologically, residual xenograft particles (31.97%±3.52%) were surrounded by either newly formed bone (16.02%±7.06%) or connective tissue (50.67%±8.42%) without fibrous encapsulation. The CM underwent a physiological substitution process in favour of well-vascularised collagen-rich connective tissue. Conclusions Socket preservation using demineralised bovine bone mineral in combination with CM provided stable dimensional changes of the alveolar ridge associated with good re-epithelialisation of the soft tissues during a 6-month healing period. PMID:28861284
Lee, Chun-Teh; Tao, Chih-Yun; Stoupel, Janet
2016-02-01
Immediate implantation, despite many advantages, carries a risk of gingival recession, papilla loss, collapse of ridge contour, and other esthetic complications. Soft tissue graft placement combined with immediate implantation may be used to reduce these concerns. This review aims to systematically analyze clinical esthetic outcomes of the immediate implant combined with soft tissue graft (IMITG). The PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines for systematic reviews were used. The electronic search was conducted using MEDLINE (PubMed), EMBASE, and Cochrane Central Register of Controlled Trials (CENTRAL) from January 1980 to October 2014. Quality assessments of selected articles were performed. Mid-buccal gingival level, interproximal gingival level, facial gingival thickness, gingival ridge dimension, and width of keratinized gingiva were the esthetic outcomes reviewed. Weighted mean difference of mid-buccal gingival level (WDBGL), papilla index score (WDPIS), and width of keratinized gingiva (WDKG) between initial and last measurements were calculated. Other esthetic outcomes were assessed by the descriptive analysis. Ten studies with a minimum of 6-month follow-up were included, and reported esthetic outcomes were analyzed. Mid-buccal gingival level (WDBGL, 0.07 mm; 95% confidence interval [CI] = -0.44 to 0.59; P = 0.12) and interproximal gingival level did not significantly change after IMITG (WDPIS in the mesial site, 0.31; 95% CI = -0.01 to 0.64; P = 0.06; and WDPIS in the distal site, 0.29; 95% CI = -0.06 to 0.65; P = 0.11). Width of keratinized gingiva significantly increased after IMITG (WDKG, 1.27 mm; 95% CI = -0.08 to 2.46; P = 0.04). Facial gingival thickness and gingival ridge dimension could be increased after IMITG. Because of the heterogeneity and limited number of selected studies, no conclusive statement could be made regarding the benefit of IMITG on esthetic outcomes. More randomized controlled trials are needed to provide definite clinical evidence.
NASA Astrophysics Data System (ADS)
Arhatari, Benedicta D.; Abbey, Brian
2018-01-01
Ross filter pairs have recently been demonstrated as a highly effective means of producing quasi-monoenergetic beams from polychromatic X-ray sources. They have found applications in both X-ray spectroscopy and for elemental separation in X-ray computed tomography (XCT). Here we explore whether they could be applied to the problem of metal artefact reduction (MAR) for applications in medical imaging. Metal artefacts are a common problem in X-ray imaging of metal implants embedded in bone and soft tissue. A number of data post-processing approaches to MAR have been proposed in the literature, however these can be time-consuming and sometimes have limited efficacy. Here we describe and demonstrate an alternative approach based on beam conditioning using Ross filter pairs. This approach obviates the need for any complex post-processing of the data and enables MAR and segmentation from the surrounding tissue by exploiting the absorption edge contrast of the implant.
Impression of multiple implants using photogrammetry: Description of technique and case presentation
Peñarrocha-Oltra, David; Agustín-Panadero, Rubén; Bagán, Leticia; Giménez, Beatriz
2014-01-01
Aim: To describe a technique for registering the positions of multiple dental implants using a system based on photogrammetry. A case is presented in which a prosthetic treatment was performed using this technique. Study Design: Three Euroteknika® dental implants were placed to rehabilitate a 55-year-old male patient with right posterior maxillary edentulism. Three months later, the positions of the implants were registered using a photogrammetry-based stereo-camera (PICcamera®). After processing patient and implant data, special abutments (PICabutment®) were screwed onto each implant. The PICcamera® was then used to capture images of the implant positions, automatically taking 150 images in less than 60 seconds. From this information a file was obtained describing the relative positions – angles and distances – of each implant in vector form. Information regarding the soft tissues was obtained from an alginate impression that was cast in plaster and scanned. A Cr-Co structure was obtained using CAD/CAM, and its passive fit was verified in the patient’s mouth using the Sheffield test and the screw resistance test. Results and Conclusions: Twelve months after loading, peri-implant tissues were healthy and no marginal bone loss was observed. The clinical application of this new system using photogrammetry to record the position of multiple dental implants facilitated the rehabilitation of a patient with posterior maxillary edentulism by means of a prosthesis with optimal fit. The prosthetic process was accurate, fast, simple to apply and comfortable for the patient. Key words:Dental implants, photogrammetry, dental impression technique, CAD/CAM. PMID:24608216
Implant rehabilitation in bruxism patient
Goiato, Marcelo Coelho; Sonego, Mariana Vilela; dos Santos, Daniela Micheline; da Silva, Emily Vivianne Freitas
2014-01-01
A white female patient presented to the university clinic to obtain implant retained prostheses. She had an edentulous maxillary jaw and presented three teeth with poor prognosis (33, 34 and 43). The alveolar bone and the surrounding tissues were healthy. The patient did not report any relevant medical history contraindicating routine dental treatment or implant surgery, but self-reported a dental history of asymptomatic nocturnal bruxism. The treatment plan was set and two Branemark protocols supported by six implants in each arch were installed after a 6-month healing period. A soft occlusal splint was made due to the patient's history of bruxism, and the lack of its use by the patient resulted in an acrylic fracture. The prosthesis was repaired and the importance of using the occlusal splint was restated. In the 4-year follow-up no fractures were reported. PMID:24907215
Lu, Pei-Lin; Lai, Jui-Yang; Tabata, Yasuhiko; Hsiue, Ging-Ho
2008-07-01
In this study, a novel methodology based on the anterior chamber of rabbit eyes model was developed to evaluate the in vivo biocompatibility of biomaterials in an immune privileged site. The 7-mm-diameter membrane implants made from either a biological tissue material (amniotic membrane, AM group) or a biomedical polymeric material (gelatin, GM group) were inserted in rabbit anterior chamber for 36 months and characterized by biomicroscopic examinations, intraocular pressure measurements, and corneal thickness measurements. The noninvasive ophthalmic parameters were scored to provide a quantitative grading system. In this animal model, both AM and GM implants were visible in an ocular immune privileged site during clinical observations. The implants of the AM group appeared as soft tissue patches and have undergone a slow dissolution process resulting in a partial reduction of their size. Additionally, the AM implants did not induce any foreign body reaction or change in ocular tissue response for the studied period. By contrast, in the GM groups, significant corneal edema, elevated intraocular pressure, and increased corneal thickness were noted in the early postoperative phase (within 3 days), but resolved rapidly with in vivo dissolution of the gelatin. The results from the ocular grading system showed that both implants had good long-term biocompatibility in an ocular immune privileged site for up to 3 years. It is concluded that the anterior chamber of rabbit eyes model is an efficient method for noninvasively determining the immune privileged tissue/biomaterial interactions. (c) 2007 Wiley Periodicals, Inc.
2011-01-01
Background The soft tissue around dental implants forms a barrier between the oral environment and the peri-implant bone and a crucial factor for long-term success of therapy is development of a good abutment/soft-tissue seal. Sol-gel derived nanoporous TiO2 coatings have been shown to enhance soft-tissue attachment but their effect on adhesion and biofilm formation by oral bacteria is unknown. Methods We have investigated how the properties of surfaces that may be used on abutments: turned titanium, sol-gel nanoporous TiO2 coated surfaces and anodized Ca2+ modified surfaces, affect biofilm formation by two early colonizers of the oral cavity: Streptococcus sanguinis and Actinomyces naeslundii. The bacteria were detected using 16S rRNA fluorescence in situ hybridization together with confocal laser scanning microscopy. Results Interferometry and atomic force microscopy revealed all the surfaces to be smooth (Sa ≤ 0.22 μm). Incubation with a consortium of S. sanguinis and A. naeslundii showed no differences in adhesion between the surfaces over 2 hours. After 14 hours, the level of biofilm growth was low and again, no differences between the surfaces were seen. The presence of saliva increased the biofilm biovolume of S. sanguinis and A. naeslundii ten-fold compared to when saliva was absent and this was due to increased adhesion rather than biofilm growth. Conclusions Nano-topographical modification of smooth titanium surfaces had no effect on adhesion or early biofilm formation by S. sanguinis and A. naeslundii as compared to turned surfaces or those treated with anodic oxidation in the presence of Ca2+. The presence of saliva led to a significantly greater biofilm biovolume but no significant differences were seen between the test surfaces. These data thus suggest that modification with sol-gel derived nanoporous TiO2, which has been shown to improve osseointegration and soft-tissue healing in vivo, does not cause greater biofilm formation by the two oral commensal species tested than the other surfaces. PMID:21385428
Wanner, Laura; Ludwig, Ute; Hövener, Jan-Bernd; Nelson, Katja; Flügge, Tabea
2018-04-01
Compared with cone beam computed tomography (CBCT), magnetic resonance imaging (MRI) might be superior for the diagnosis of nerve lesions associated with implant placement. A patient presented with unilateral pain associated with dysesthesia in the region of the right lower lip and chin after implant placement. Conventional orthopantomography could not identify an association between the position of the inferior alveolar nerve and the implant. For 3-dimensional display of the implant in relation to the surrounding anatomy, CBCT was compared with MRI. MRI enabled the precise depiction of the implant position and its spatial relation to the inferior alveolar nerve, whereas the nerve position and its exact course within the mandible could not be directly displayed in CBCT. MRI may be a valuable, radiation-free diagnostic tool for the visualization of intraoral hard and soft tissues, offering an objective assessment of nerve injuries by a direct visualization of the inferior alveolar neurovascular bundle. Copyright © 2018 Elsevier Inc. All rights reserved.
In vivo response to starch-based scaffolds designed for bone tissue engineering applications.
Salgado, A J; Coutinho, O P; Reis, R L; Davies, J E
2007-03-15
Our purpose was to evaluate the in vivo endosseous response to three starch-based scaffolds implanted in rats (n = 54). We implanted the three scaffold groups; a 50/50 (wt %) blend of corn starch and ethylene-vinyl alcohol (SEVA-C), the same composition coated with a biomimetic calcium phosphate (Ca-P) layer (SEVA-C/CaP), and a 50/50 (wt %) blend of corn starch and cellulose acetate (SCA), all produced by extrusion with blowing agents, into distal femurs proximal to the epiphyseal plate, for 1, 3, or 6 weeks. Our results showed that at 1 week considerable reparative bone formed around all scaffold groups, although the bone was separated from the scaffold by an intervening soft tissue interfacial zone that comprised two distinct compartments: the surface of the scaffold was occupied by multinucleate giant cells and the compartment between these cells and the surrounding bone was occupied by a streaming fibrous-like tissue. The extracellular matrix of the latter was continuous with the extracellular bone matrix itself, labeled positively for osteocalcin and appeared mineralized by back-scattered electron imaging. All three scaffolds showed a similar tissue response, with the soft tissue interface diminishing with time. No bone contact was observed with SEVA-C at any time point, only transitory bone contact was observed with SEVA-C/CaP at 3 weeks, but SCA exhibited direct bone contact at 6 weeks where 56.23 +/- 6.46% of the scaffold surface was occupied by bone. We conclude that all materials exhibited a favorable bony response and that the rapidly forming initial "connective tissue" seen around all scaffolds was a very early form of bone formation.
Wada, Susumu; Kitamura, Nobuto; Nonoyama, Takayuki; Kiyama, Ryuji; Kurokawa, Takayuki; Gong, Jian Ping; Yasuda, Kazunori
2016-10-15
We have developed a novel hydroxyapatite (HAp)-coated double-network (DN) hydrogel (HAp/DN gel). The purpose of this study was to determine details of the cell and tissue responses around the implanted HAp/DN gel and to determine how quickly and strongly the HAp/DN gel bonds to the bone in a rabbit osteochondral defect model. Immature osteoid tissue was formed in the space between the HAp/DN gel and the bone at 2weeks, and the osteoid tissue was mineralized at 4weeks. The push-out load of the HAp/DN gel averaged 37.54N and 42.15N at 4 and 12weeks, respectively, while the push-out load of the DN gel averaged less than 5N. The bonding area of the HAp/DN gel to the bone was above 80% by 4weeks, and above 90% at 12weeks. This study demonstrated that the HAp/DN gel enhanced osseointegration at an early stage after implantation. The presence of nanoscale structures in addition to osseointegration of HAp promoted osteoblast adhesion onto the surface of the HAp/DN gel. The HAp/DN gel has the potential to improve the implant-tissue interface in next-generation orthopaedic implants such as artificial cartilage. Recent studies have reported the development of various hydrogels that are sufficiently tough for application as soft supporting tissues. However, fixation of hydrogels on bone surfaces with appropriate strength is a great challenge. We have developed a novel, tough hydrogel hybridizing hydroxyapatite (HAp/DN gel), which is directly bondable to the bone. The present study demonstrated that the HAp/DN gel enhanced osseointegration in the early stage after implantation. The presence of nanoscale structures in addition to the osseointegration ability of hydroxyapatite promoted osteoblast adhesion onto the surface of the HAp/DN gel. The HAp/DN gel has the potential to improve the implant-tissue interface in next-generation orthopaedic implants such as artificial cartilage. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Jung, Ronald E; Herzog, Milan; Wolleb, Karin; Ramel, Christian F; Thoma, Daniel S; Hämmerle, Christoph H F
2017-03-01
The aim of the present randomized controlled clinical study was to test whether small bony dehiscence defects (≤5 mm) left to heal spontaneously result in the same clinical and radiological outcome as defects treated with guided bone regeneration (GBR). Twenty-two patients who received at least one implant with a small bony dehiscence defect were enrolled in the study. If the defect height was ≤5 mm, the site was randomly assigned to either the spontaneous healing (SH) group or the GBR group. In the SH group, the defect was left without any treatment. In the GBR group, the defects around the implants were grafted with deproteinized bovine bone mineral (DBBM) and covered with a native collagen membrane. Clinical and radiographic measurements were performed 6 months after implant placement with a reentry surgery and at the time of crown insertion and the subsequent follow-up appointments at 3, 6, 12 and 18 months after loading. For statistical analyses, the mixed linear model was applied for the clinical and radiographic measurements observed around the implants. Simple comparisons of the location of the measurements in the two independent groups are performed with the Mann-Whitney U-test. In addition, the mixed model assumptions were checked. The implant and crown survival rate 18 months after loading was 100%, revealing no serious biologic or prosthetic complication. The mean changes of the buccal vertical bone height between implant placement and reentry surgery after 6 months revealed a small bone loss of -0.17 ± 1.79 mm (minimum -4 mm and maximum 2.5 mm) for the SH group and a bone gain of 1.79 ± 2.24 mm (minimum of -2.5 mm and maximum of 5 mm) for the GBR group, respectively (P = 0.017). Radiographic measurements demonstrated a slight bone loss of -0.39 ± 0.49 mm for the SH group and a stable bone level of 0.02 ± 0.48 mm for GBR group after 18 months. All peri-implant soft tissue parameters revealed healthy tissues with no difference between the two groups. Small bony dehiscence defects left for spontaneous healing demonstrated high implant survival rates with healthy and stable soft tissues. However, they revealed more vertical bone loss at the buccal aspect 6 months after implant insertion and also more marginal bone loss between crown insertion and 18 months after loading compared to sites treated with GBR. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Delayed Implants Outcome in Maxillary Molar Region.
Crespi, Roberto; Capparè, Paolo; Crespi, Giovanni; Gastaldi, Giorgio; Gherlone, Enrico F
2017-04-01
The aim of the present study was to assess bone volume changes in maxillary molar regions after delayed implants placement. Patients presented large bone defects after tooth extractions. Reactive soft tissue was left into the defects. No grafts were used. Cone beam computed tomography (CBCT) scans were performed before tooth extractions, at implant placement (at 3 months from extraction) and 3 years after implant placement, bone volume measurements were assessed. Bucco-lingual width showed a statistically significant decrease (p = .013) at implant placement, 3 months after extraction. Moreover, a statistically significant increase (p < .01) was measured 3 years after implant placement. No statistically significant differences (p > .05) were found between baseline values (before extraction) and at 3 years from implant placement. Vertical dimension showed no statistically significant differences (p > .05) at implant placement, 3 months after extraction. Statistically significant differences (p < .0001) were found between baseline values (before extraction) and at 3 months from implant placement as well as between implant placement values and 3 years later. CT scans presented successful outcome of delayed implants placed in large bone defects at 3-year follow-up. © 2016 Wiley Periodicals, Inc.
Ichikawa, Kazunori; Kashio, Akinori; Mori, Harushi; Ochi, Atushi; Karino, Shotaro; Sakamoto, Takashi; Kakigi, Akinobu; Yamasoba, Tatsuya
2014-04-01
To develop a new method to determine the presence of intracochlear ossification and/or fibrosis in cochlear implantation candidates with bilateral profound deafness following meningitis. Diagnostic test assessment. A university hospital. This study involved 15 ears from 13 patients with profound deafness following meningitis who underwent cochlear implantation. These ears showed normal structures, soft tissue, partial bony occlusion, and complete bony occlusion in 4, 3, 2, and 6 ears, respectively. We measured radiodensity in Hounsfield units (HU) using 0.5-mm-thick axial high-resolution computed tomography image slices at 3 different levels in the basal turn, the fenestration, and inferior and ascending segment sites, located along the electrode-insertion path. Pixel-level analysis on the DICOM viewer yielded actual computed tomography values of intracochlear soft tissues by eliminating the partial volume effect. The values were compared with the intraoperative findings. Values for ossification (n = 12) ranged from +547 HU to +1137 HU; for fibrosis (n = 11), from +154 HU to +574 HU; and for fluid (n = 22), from -49 HU to +255 HU. From these values, we developed 2 presets of window width (WW) and window level (WL): (1) WW: 1800, WL: 1100 (200 HU to 2000 HU) and (2) WW: 1500, WL: 1250 (500 HU to 2000 HU). The results using these 2 presets corresponded well to the intraoperative findings. Our new method is easy and feasible for preoperative determination of the presence of cochlear ossification and/or fibrosis that develops following meningitis.
Implant site development by orthodontic forced eruption of nontreatable teeth: a case report.
Rokn, Amir Reza; Saffarpour, Anna; Sadrimanesh, Rouzbeh; Iranparvar, Kaveh; Saffarpour, Aida; Mahmoudzadeh, Majid; Soolari, Ahmad
2012-01-01
Loss of bone and soft tissue attachment are common sequelae of periodontitis that may jeopardize the aesthetic outcome and compromise the functional and aesthetic outcomes of treatment. The following case report describes one of the most predictable techniques of vertical ridge augmentation, which is orthodontic extrusion or forced eruption of hopeless teeth. A 34-year-old woman who presented with severe attachment loss and deep pockets was diagnosed with generalized aggressive periodontitis. The mobile maxillary incisors were consequently extracted and were replaced with dental implants. However, prior to extraction, orthodontic extrusion of the hopeless incisors was performed to correct vertical ridge defects. Following extrusion and extraction of the maxillary incisors, to prevent soft tissue collapse and to preserve the papillae during socket healing, the crowns of the extracted teeth were used as pontics on a removable partial provisional denture. After 8 weeks, the implants were placed, and an immediate functional restoration was delivered. After 4 months of healing, a fixed definitive partial prosthesis was fabricated and delivered. After periodontal treatment, over a 2-year period, the progression of aggressive periodontitis was controlled. The mean vertical movement of marginal bone was 3.6 mm. The use of the crowns of extracted teeth appears to be an effective method to maintain papillae. Orthodontic extrusion is a predictable method for the correction of vertical ridge defects. Orthodontic treatment does not aggravate or hasten the progression of aggressive periodontitis.
Takahashi, Hironobu; Wang, Yuwei; Grainger, David W.
2010-01-01
Fibrous encapsulation of surgically implant devices is associated with elevated proliferation and activation of fibroblasts in tissues surrounding these implants, frequently causing foreign body complications. Here we test the hypothesis that inhibition of the expression of mammalian target of rapamycin (mTOR) in fibroblasts can mitigate the soft tissue implant foreign body response by suppressing fibrotic responses around implants. In this study, mTOR was knocked down using small interfering RNA conjugated with branched cationic polyethylenimine (bPEI) in fibroblastic lineage cells in serum-based cell culture as shown by both gene and protein analysis. This mTOR knockdown led to an inhibition in fibroblast proliferation by 70% and simultaneous down-regulation in the expression of type I collagen in fibroblasts in vitro. These siRNA/bPEI complexes were released from poly(ethylene glycol) (PEG)-based hydrogel coatings surrounding model polymer implants in a subcutaneous rodent model in vivo. No significant reduction in fibrous capsule thickness and mTOR expression in the foreign body capsules was observed. Observed siRNA inefficacy in this in vivo implant model was attributed to siRNA dosing limitations in the gel delivery system, and lack of targeting ability of the siRNA complex specifically to fibroblasts. While in vitro data supported mTOR knock-down in fibroblast cultures, in vivo siRNA delivery must be further improved to produce clinically relevant effects on fibrotic encapsulation around implants. PMID:20727922
Valic, Blaz; Gajsek, Peter; Miklavcic, Damijan
2009-10-01
A numerical model of a human body with an intramedullary nail in the femur was built to evaluate the effects of the implant on the current density distribution in extremely low frequency electric and magnetic fields. The intramedullary nail was chosen because it is one of the longest high conductive implants used in the human body. As such it is expected to alter the electric and magnetic fields significantly. The exposure was a simultaneous combination of inferior to superior electric field and posterior to anterior magnetic field both alternating at 50 Hz with the values corresponding to the ICNIRP reference levels: 5000 V m(-1) for electric field and 100 microT for magnetic flux density. The calculated current density distribution inside the model was compared to the ICNIRP basic restrictions for general public (2 mA m(-2)). The results show that the implant significantly increases the current density up to 9.5 mA m(-2) in the region where it is in contact with soft tissue in the model with the implant in comparison to 0.9 mA m(-2) in the model without the implant. As demonstrated the ICNIRP basic restrictions are exceeded in a limited volume of the tissue in spite of the compliance with the ICNIRP reference levels for general public, meaning that the existing safety limits do not necessarily protect implanted persons to the same extent as they protect people without implants.
Omori, Shinsuke; Hamada, Kenichiro; Outani, Hidetatsu; Oshima, Kazuya; Joyama, Susumu; Tomita, Yasuhiko; Naka, Norifumi; Araki, Nobuhito; Yoshikawa, Hideki
2015-05-12
In patients with soft tissue sarcoma of the wrist and hand, limb salvage operation is extremely challenging for surgeons in attempting a complete tumor resection with negative surgical margins. In this study, we report four patients with soft tissue sarcoma of the wrist and hand treated by limb salvage operation with intraoperative extracorporeal autogenous irradiated tendon grafts. The patients were all male, and the mean age at the time of surgery was 45 years. Histological diagnoses included clear cell sarcoma in two patients, synovial sarcoma in one, and angiosarcoma in one. All four patients had high grade tumors, wherein three had American Joint Committee on Cancer (AJCC) stage III disease and one with AJCC stage IV disease. The tumors were resected en bloc with involved tendons. The tendons were isolated from the resected tissues, irradiated ex vivo, and re-implanted into the host tendons. In one patient, the bone was resected additionally because of tumor invasion to the bone. Hand function was evaluated using Musculoskeletal Tumor Society (MSTS) rating system. Of the four patients, three died of distant metastatic disease. The remaining patient lives and remains disease-free. The mean follow-up period was 33 months. One patient had local recurrence outside the irradiated graft at 20 months after surgery. The functional rating was 22. Lower scores were seen in patients with reconstruction of flexor tendons than extensor tendons. Limb salvage operation with intraoperative extracorporeal autogenous irradiated tendon grafts is an acceptable method in selected patients with soft tissue sarcoma of the wrist and hand.
Wurm, Gabriele; Tomancok, Berndt; Holl, Kurt; Trenkler, Johannes
2004-12-01
The aim of this study was to evaluate the value of carbon fiber reinforced polymer (CFRP) cranial implants produced by means of 3-dimensional (3D) stereolithography (SL) and template modeling for reconstructions of complex or extensive cranial defects. A series of 41 cranioplasties with individual CFRP implants was performed in 37 patients between April 1996 and November 2002. Only patients with complex and/or large cranial defects were included, most of them having extended scarring or dural calcification and poor quality of the overlying soft-tissue cover after infection or multiple preceding operations. Involvement of frontal sinus, a known risk factor for complications after cranioplasty, was the case in 21 patients (51.2%). A computer-based 3D model of the skull with the bony defect was generated by means of stereolithography after acquisition, evaluation and transfer of the patient's helical computed tomography (CT) data. A wax template of the defect that was used to design the individual prosthesis-shape was invested in dental stone. Then, the cranial implant was fabricated out of CFRP by loosen mold. Reconstruction of defects measuring up to 17 x 9 cm was performed. The intra-operative fit of the implants was excellent in 36 (87.8%), good in 1 (2.4%), and fair in 4 (9.8%) of the cases. Problems of implant fit occurred because of extended scarring and poor quality of soft-tissue cover. Adverse reactions were observed in 5 patients (1 subdural, 1 subcutaneous hematoma, 2 infections, 1 allergic reaction). Excellent contours and a solid stable reconstruction have been maintained in 30 out of 35 remaining plates (mean follow-up 3.6 years). No adverse effects concerning postoperative imaging, the accuracy of electroencephalograms and radiation therapy have been observed. The authors believe that this relatively new technique represents an advance in the management of complex and large cranial defects, but seems less suitable for simple defects because of cost-intensive techniques. Because of the high mechanical strength, biocompatibility, innovative design, and especially radiolucency, CFRP implants should, however, be considered in smaller defects if further imaging investigations or irradiation therapies are necessary.
Recent advances of ultrasound imaging in dentistry--a review of the literature.
Marotti, Juliana; Heger, Stefan; Tinschert, Joachim; Tortamano, Pedro; Chuembou, Fabrice; Radermacher, Klaus; Wolfart, Stefan
2013-06-01
Ultrasonography as an imaging modality in dentistry has been extensively explored in recent years due to several advantages that diagnostic ultrasound provides. It is a non-invasive, inexpensive, painless method and unlike X-ray, it does not cause harmful ionizing radiation. Ultrasound has a promising future as a diagnostic imaging tool in all specialties in dentistry, for both hard and soft tissue detection. The aim of this review is to provide the scientific community and clinicians with an overview of the most recent advances of ultrasound imaging in dentistry. The use of ultrasound is described and discussed in the fields of dental scanning, caries detection, dental fractures, soft tissue and periapical lesions, maxillofacial fractures, periodontal bony defects, gingival and muscle thickness, temporomandibular disorders, and implant dentistry. Copyright © 2013 Elsevier Inc. All rights reserved.
Damage control and intramedullary nailing for long bone fractures in polytrauma patients.
Patka, Peter
2017-06-01
The early fracture treatment in patients with multiple injuries should be focused on damage control. The fracture type and its location, local soft tissue condition as well as the patient's physiological condition shall determine the time and type of fracture treatment. Prevention of local and systemic complications must be immediately considered and included in the treatment planning. The use of external fixator (ExFix), which will be replaced by IM-implants in most cases at a later stage, provides adequate temporary fracture stabilization with less collateral damage. Good clinical results can be expected in patients with long bone fractures if the principles of damage control surgery are applied and local complications are prevented through proper reduction, firm fixation, early soft tissue reconstruction, and early rehabilitation. Copyright © 2017 Elsevier Ltd. All rights reserved.
The effect of total knee arthroplasty on body weight.
Lee, Gwo-Chin; Cushner, Fred D; Cannella, Laura Y; Scott, W Norman
2005-03-01
This prospective study quantified the weight change in 20 consecutive patients undergoing total knee arthroplasty. Resected bone, soft tissues, and bone reamings were collected during surgery and weighed using a digital scale at the end of the procedure. Results were compared to the cumulative weights of the prosthesis, bone cement, patellar component, and polyethylene liner. Average weight of the resected bone and soft tissues was 167.71 g for men and 130.13 g for women. Mean weight of the implanted prosthesis and cement used was 509.92 g for men and 422.56 g for women. Men tended to receive a larger-sized prosthesis than women. Overall, the average weight gain as a result of knee arthroplasty was 345.54 g for men and 292.44 g for women. This translates to an insignificant increase in body weight.
Piezosurgical osteotomy for harvesting intraoral block bone graft
Lakshmiganthan, Mahalingam; Gokulanathan, Subramanium; Shanmugasundaram, Natarajan; Daniel, Rajkumar; Ramesh, Sadashiva B.
2012-01-01
The use of ultrasonic vibrations for the cutting of bone was first introduced two decades ago. Piezoelectric surgery is a minimally invasive technique that lessens the risk of damage to surrounding soft tissues and important structures such as nerves, vessels, and mucosa. It also reduces damage to osteocytes and permits good survival of bony cells during harvesting of bone. Grafting with intraoral bone blocks is a good way to reconstruct severe horizontal and vertical bone resorption in future implants sites. The piezosurgery system creates an effective osteotomy with minimal or no trauma to soft tissue in contrast to conventional surgical burs or saws and minimizes a patient's psychological stress and fear during osteotomy under local anesthesia. The purpose of this article is to describe the harvesting of intraoral bone blocks using the piezoelectric surgery device. PMID:23066242
Oral mucosa tissue response to titanium cover screws.
Olmedo, Daniel G; Paparella, María L; Spielberg, Martín; Brandizzi, Daniel; Guglielmotti, María B; Cabrini, Rómulo L
2012-08-01
Titanium is the most widely used metal in dental implantology. The release of particles from metal structures into the biologic milieu may be the result of electrochemical processes (corrosion) and/or mechanical disruption during insertion, abutment connection, or removal of failing implants. The aim of the present study is to evaluate tissue response of human oral mucosa adjacent to titanium cover screws. One hundred fifty-three biopsies of the supra-implant oral mucosa adjacent to the cover screw of submerged dental implants were analyzed. Histologic studies were performed to analyze epithelial and connective tissue as well as the presence of metal particles, which were identified using microchemical analysis. Langerhans cells, macrophages, and T lymphocytes were studied using immunohistochemical techniques. The surface of the cover screws was evaluated by scanning electron microscopy (SEM). Forty-one percent of mucosa biopsies exhibited metal particles in different layers of the section thickness. Particle number and size varied greatly among specimens. Immunohistochemical study confirmed the presence of macrophages and T lymphocytes associated with the metal particles. Microchemical analysis revealed the presence of titanium in the particles. On SEM analysis, the surface of the screws exhibited depressions and irregularities. The biologic effects seen in the mucosa in contact with the cover screws might be associated with the presence of titanium or other elements, such as aluminum or vanadium. The potential long-term biologic effects of particles on soft tissues adjacent to metallic devices should be further investigated because these effects might affect the clinical outcome of the implant.
Yu, Na; Bronckers, Antonius L J J; Oortgiesen, Daniel A W; Yan, Xiangzhen; Jansen, John A; Yang, Fang; Walboomers, X Frank
2015-01-01
Periodontitis is the most common human infectious disease. Regeneration of bone and soft tissue defects after periodontitis remains challenging, although the transplantation of periodontal ligament (PDL) cells seems a liable strategy. However, little is known about the function of PDL cells after transplantation. In the current study, a combination of in vitro coculture systems and in vivo immunohistochemistry (IHC) was used to investigate the role of PDL cells in the regenerative process. First, a coculture method was used, in which mesenchymal cells (representing the host tissue) were brought into direct contact with PDL cells (representing the transplanted cell population). It was found that PDL cells significantly increased mineralized matrix formation and osteocalcin expression, whereas control cells did not. Similar results were obtained when a noncontact coculture system was applied separating PDL and mesenchymal cells. In an in vivo rat model, regeneration of alveolar bone and ligament was seen after PDL cell transplantation. Implanted PDL cells were found clustered along the newly formed tissues. IHC showed enhanced osteopontin expression and gap junction staining in areas neighboring implanted PDL cells. In conclusion, PDL cells enhance periodontal regeneration through a trophic factor stimulating the osteogenic activity of the surrounding host cells.
A 5-year prospective study on single immediate implants in the aesthetic zone.
Cosyn, Jan; Eghbali, Aryan; Hermans, Alexander; Vervaeke, Stijn; De Bruyn, Hugo; Cleymaet, Roberto
2016-08-01
There is a paucity of long-term data on soft tissue aesthetics of single immediate implants. The objective of this study was to evaluate the 5-year clinical and aesthetic outcome of this treatment concept. Twenty-two periodontally healthy patients (12 men, 10 women; mean age 50) with low risk for aesthetic complications (thick gingival biotype, intact buccal bone wall, both neighbouring teeth present) were consecutively treated with a single immediate implant in the aesthetic zone (15-25). Flapless surgery was performed and the gap between the implant and buccal bone wall was systematically filled with bovine bone particles. Implants were immediately non-functionally loaded with a screw-retained provisional crown. Cases demonstrating major alveolar process changes and/or advanced mid-facial recession (>1 mm) at 3 months were additionally treated with a connective tissue graft (CTG). Permanent crowns were installed at 6 months. The clinical and aesthetic results at 5 years were compared to those obtained at 1 year. Seventeen patients attended the 5-year re-assessment, of whom five had been treated with a CTG for early aesthetic complications. There was one early implant failure and one complication after 1 year (porcelain chipping). Mean marginal bone loss was 0.12 mm at 1 year and 0.19 mm at 5 years (p = 0.595) with the moment of implant installation as baseline. Papilla height increased between 1 and 5 years (p ≤ 0.007), whereas mid-facial contour (p = 0.005) and alveolar process deficiency (p = 0.008) deteriorated. Mean mid-facial recession was on average 0.28 mm (SD 0.48) at 1 year and 0.53 mm (SD 0.53) at 5 years (p = 0.072) with the preoperative status as baseline. Three implants demonstrated advanced mid-facial recession (>1 mm) at 5 years. All three were in a central incisor position and none had been treated with a CTG. Thus, 8/17 implants showed aesthetic complications (five early and three late aesthetic complications). Implants in a lateral incisor position showed stable soft tissue levels. The pink aesthetic score was on average 12.15 at 1 year and 11.18 at 5 years (p = 0.030). Single immediate implants showed high implant survival and limited marginal bone loss in the long term. However, mid-facial recession, mid-facial contour and alveolar process deficiency deteriorated after 1 year. With an aesthetic complication rate of 8/17 in well-selected patients who had been treated by experienced clinicians, type I placement may not be recommended for daily practice. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
A Biodesigned Nanocomposite Biomaterial for Auricular Cartilage Reconstruction.
Nayyer, Leila; Jell, Gavin; Esmaeili, Ali; Birchall, Martin; Seifalian, Alexander M
2016-05-01
Current biomaterials for auricular replacement are associated with high rates of infection and extrusion. The development of new auricular biomaterials that mimic the mechanical properties of native tissue and promote desirable cellular interactions may prevent implant failure. A porous 3D nanocomposite scaffold (NS) based on POSS-PCU (polyhedral oligomeric silsesquioxane nanocage into polycarbonate based urea-urethane) is developed with an elastic modulus similar to native ear. In vitro biological interactions on this NS reveal greater protein adsorption, increased fibroblast adhesion, proliferation, and collagen production compared with Medpor (the current synthetic auricular implant). In vivo, the POSS-PCU with larger pores (NS2; 150-250 μm) have greater tissue ingrowth (≈5.8× and ≈1.4 × increase) than the POSS-PCU with smaller pores (NS1; 100-50 μm) and when compared to Medpor (>100 μm). The NS2 with the larger pores demonstrates a reduced fibrotic encapsulation compared with NS1 and Medpor (≈4.1× and ≈1.6×, respectively; P < 0.05). Porosity also influences the amount of neovascularization within the implants, with no blood vessel observed in NS1 (12 weeks postimplantation). The lack of chronic inflammatory response for all materials may indicate that the elastic modulus and pore size of the implant scaffold could be important design considerations for influencing fibrotic responses to auricular and other soft tissue implants. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Canullo, Luigi; Peñarrocha-Oltra, David; Marchionni, Silvia; Bagán, Leticia; Micarelli, Costanza
2014-01-01
Objectives: A randomized controlled trial was performed to assess soft tissue cell adhesion to implant titanium abutments subjected to different cleaning procedures and test if plasma cleaning can enhance cell adhesion at an early healing time. Study Design: Eighteen patients with osseointegrated and submerged implants were included. Before re-opening, 18 abutments were divided in 3 groups corresponding to different clinical conditions with different cleaning processes: no treatment (G1), laboratory customization and cleaning by steam (G2), cleaning by plasma of Argon (G3). Abutments were removed after 1 week and scanning electron microscopy was used to analyze cell adhesion to the abutment surface quantitatively (percentage of area occupied by cells) and qualitatively (aspect of adhered cells and presence of contaminants). Results: Mean percentages of area occupied by cells were 17.6 ± 22.7%, 16.5 ± 12.9% and 46.3 ± 27.9% for G1, G2 and G3 respectively. Differences were statistically significant between G1 and G3 (p=0.030), close to significance between G2 and G3 (p=0.056), and non-significant between G1 and G2 (p=0.530). The proportion of samples presenting adhered cells was homogeneous among the 3 groups (p-valor = 1.000). In all cases cells presented a flattened aspect; in 2 cases cells were less efficiently adhered and in 1 case cells presented filipodia. Three cases showed contamination with cocobacteria. Conclusions: Within the limits of the present study, plasma of Argon may enhance cell adhesion to titanium abutments, even at the early stage of soft tissue healing. Further studies with greater samples are necessary to confirm these findings. Key words:Connective tissue, dental abutments, randomized controlled trial, clinical research, glow discharged abutment, plasma cleaning. PMID:24121917
Kaner, Dogan; Zhao, Han; Terheyden, Hendrik; Friedmann, Anton
2015-06-01
We investigated the effect of soft tissue expansion (STE) on vertical ridge augmentation with regard to the incidence of wound dehiscences and the impairment of microcirculation in dogs, and the applicability of laser Doppler flowmetry (LDF) to explore the relation between microcirculation and wound healing. Bone defects were created on both mandibular sides in ten beagle dogs by extraction of premolars and removal of bone. Six weeks later, self-filling tissue expanders were implanted in randomly assigned test sites. After 5 weeks of expansion, vertical augmentation was carried out in test and control sites using calvarial onlay grafts side by side with granular biphasic calcium phosphate covered with a resorbable polyethylene glycol membrane. Microcirculation was evaluated with laser Doppler flowmetry (LDF). The incidence of wound dehiscences was evaluated after 2 weeks. The validity of LDF to predict dehiscences was evaluated by construction of receiver operating characteristic (ROC) curves. After augmentation, test sites showed significantly better perfusion than control sites without preceding STE (P = 0.012). Three days after surgery, perfusion was still significantly decreased in control sites (P = 0.005), while microcirculation in test sites had returned to pre-surgical levels. After 2 weeks, healing in test sites was good, whereas eight dehiscences were found in control sites (P = 0.002). ROC curves showed that microcirculation levels immediately after augmentation surgery significantly predicted subsequent wound dehiscences (AUC = 0.799, CI 0.642-0.955, P = 0.006). Laser Doppler flowmetry is suitable for evaluation of soft tissue microcirculation after ridge augmentation. STE reduced the impairment of microcirculation caused by vertical ridge augmentation and decreased the incidence of wound dehiscences in the investigated animal model. © 2014 The Authors. Clinical Oral Implants Research Published by John Wiley & Sons Ltd.
Harris, Bryan T; Montero, Daniel; Grant, Gerald T; Morton, Dean; Llop, Daniel R; Lin, Wei-Shao
2017-02-01
This clinical report proposes a digital workflow using 2-dimensional (2D) digital photographs, a 3D extraoral facial scan, and cone beam computed tomography (CBCT) volumetric data to create a 3D virtual patient with craniofacial hard tissue, remaining dentition (including surrounding intraoral soft tissue), and the realistic appearance of facial soft tissue at an exaggerated smile under static conditions. The 3D virtual patient was used to assist the virtual diagnostic tooth arrangement process, providing patient with a pleasing preoperative virtual smile design that harmonized with facial features. The 3D virtual patient was also used to gain patient's pretreatment approval (as a communication tool), design a prosthetically driven surgical plan for computer-guided implant surgery, and fabricate the computer-aided design and computer-aided manufacturing (CAD-CAM) interim prostheses. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Failure of Synthetic Implants: Strategies and Management.
Jang, Yong Ju; Kim, Shin Ae; Alharethy, Sami
2018-06-01
Dorsal augmentation with synthetic implants is the most commonly performed rhinoplasty procedure, especially in the East-Asian region. However, as in all other surgical procedures, complications are inevitable. Complications that need to be managed surgically include displacement, deviation, suboptimal aesthetic outcome, extrusion, inflammation, infection, and changes in skin quality. Most complications can be easily managed with revision surgery. After the removal of the synthetic implant from the nasal dorsum, different dorsal implant materials such as dermofat, alloderm, or fascia-wrapped diced cartilage, conchal cartilage with perichondrial attachment, and costal cartilage are preferred. An irreversible change in the skin/soft tissue envelope poses a challenge that usually requires reconstructive surgery with a local flap. Therefore, early detection and prompt management of the complication are essential for minimizing the severity of the deformity and the complexity of the surgical procedures. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Liaw, Kevin; Delfini, Ronald H; Abrahams, James J
2015-10-01
Dental implants have increased in the last few decades thus increasing the number of complications. Since many of these complications are easily diagnosed on postsurgical images, it is important for radiologists to be familiar with them and to be able to recognize and diagnose them. Radiologists should also have a basic understanding of their treatment. In a pictorial fashion, this article will present the basic complications of dental implants which we have divided into three general categories: biomechanical overload, infection or inflammation, and other causes. Examples of implant fracture, loosening, infection, inflammation from subgingival cement, failure of bone and soft tissue preservation, injury to surround structures, and other complications will be discussed as well as their common imaging appearances and treatment. Lastly, we will review pertinent dental anatomy and important structures that are vital for radiologists to evaluate in postoperative oral cavity imaging. Copyright © 2015 Elsevier Inc. All rights reserved.
A modular reactor to simulate biofilm development in orthopedic materials.
Barros, Joana; Grenho, Liliana; Manuel, Cândida M; Ferreira, Carla; Melo, Luís F; Nunes, Olga C; Monteiro, Fernando J; Ferraz, Maria P
2013-09-01
Surfaces of medical implants are generally designed to encourage soft- and/or hard-tissue adherence, eventually leading to tissue- or osseo-integration. Unfortunately, this feature may also encourage bacterial adhesion and biofilm formation. To understand the mechanisms of bone tissue infection associated with contaminated biomaterials, a detailed understanding of bacterial adhesion and subsequent biofilm formation on biomaterial surfaces is needed. In this study, a continuous-flow modular reactor composed of several modular units placed in parallel was designed to evaluate the activity of circulating bacterial suspensions and thus their predilection for biofilm formation during 72 h of incubation. Hydroxyapatite discs were placed in each modular unit and then removed at fixed times to quantify biofilm accumulation. Biofilm formation on each replicate of material, unchanged in structure, morphology, or cell density, was reproducibly observed. The modular reactor therefore proved to be a useful tool for following mature biofilm formation on different surfaces and under conditions similar to those prevailing near human-bone implants.
Autologous platelet-rich plasma as an adipocyte in vivo delivery system: case report.
Azzena, Bruno; Mazzoleni, Francesco; Abatangelo, Giovanni; Zavan, Barbara; Vindigni, Vincenzo
2008-01-01
Tissue engineering has emerged as a promising alternative to current clinical treatments for restoration of soft tissue defects. A key element in the process of tissue engineering is an ideal implant that provides structural support and a favorable environment for growing cells. The authors hypothesized that autologous platelet-rich plasma (APRP) could be used as an in vivo adipocyte delivery system to favor cell survival and to stimulate early recruitment of microcapillaries to the site of implantation. Autologous fat was included in APRP and injected as a gel into a subcutaneous pocket created to correct a painful, adherent scar at the shoulder level in a 75-year-old woman. The surgical outcome was evaluated by histologic and immunohistochemical analysis as well as by ecography before and after surgery. The results were satisfactory, showing fat survival 1 year after surgery. The characteristics of this new material should stimulate research into future clinical applications for such cell constructs in plastic and reconstructive surgery.
Initial evaluation of vascular ingrowth into superporous hydrogels.
Keskar, Vandana; Gandhi, Milind; Gemeinhart, Ernest J; Gemeinhart, Richard A
2009-08-01
There is a need for new materials and architectures for tissue engineering and regenerative medicine. Based upon our recent results developing novel scaffold architecture, we hypothesized that this new architecture would foster vascularization, a particular need for tissue engineering. We report on the potential of superporous hydrogel (SPH) scaffolds for in vivo cellular infiltration and vascularization. Poly(ethylene glycol) diacrylate (PEGDA) SPH scaffolds were implanted in the dorsum of severe combined immunodeficient (SCID) mice and harvested after 4 weeks of in vivo implantation. The SPHs were visibly red and vascularized, as apparent when compared to the non-porous hydrogel controls, which were macroscopically avascular. Host cell infiltration was observed throughout the SPHs. Blood cells and vascular structures, confirmed through staining for CD34 and smooth muscle alpha-actin, were observed throughout the scaffolds. This novel soft material may be utilized for cell transplantation, tissue engineering and in combination with cell therapies. The neovasularization and limited fibrotic response suggest that the architecture may be conducive to cell survival and rapid vessel development.
Implant decontamination with phosphoric acid during surgical peri-implantitis treatment: a RCT.
Hentenaar, Diederik F M; De Waal, Yvonne C M; Strooker, Hans; Meijer, Henny J A; Van Winkelhoff, Arie-Jan; Raghoebar, Gerry M
2017-12-01
Peri-implantitis is known as an infectious disease that affects the peri-implant soft and hard tissue. Today, scientific literature provides very little evidence for an effective intervention protocol for treatment of peri-implantitis. The aim of the present randomized controlled trial is to evaluate the microbiological and clinical effectiveness of phosphoric acid as a decontaminating agent of the implant surface during surgical peri-implantitis treatment. Peri-implantitis lesions were treated with resective surgical treatment aimed at peri-implant granulation tissue removal, bone recontouring, and pocket elimination. Fifty-three implant surfaces in 28 patients were mechanically cleaned and treated with either 35% phosphoric etching gel (test group) or sterile saline (control group). Microbiological samples were obtained during surgery; clinical parameters were recorded at baseline and at 3 months after treatment. Data were analyzed using multi-variable linear regression analysis and multilevel statistics. Significant immediate reductions in total anaerobic bacterial counts on the implant surface were found in both groups. Immediate reduction was greater when phosphoric acid was used. The difference in log-transformed mean anaerobic counts between both procedures was not statistical significant (p = 0.108), but there were significantly less culture-positive implants after the decontamination procedure in the phosphoric acid group (p = 0.042). At 3 months post-surgery, 75% of the implants in the control group and 63.3% of the implants in the test group showed disease resolution. However, no significant differences in clinical and microbiological outcomes between both groups were found. The application of 35% phosphoric acid after mechanical debridement is superior to mechanical debridement combined with sterile saline rinsing for decontamination of the implant surface during surgical peri-implantitis treatment. However, phosphoric acid as implant surface decontaminant does not seem to enhance clinical outcomes on a 3-month follow-up. Netherlands National Trial Register, NTR5185 (www.trialregister.nl).
Schiegnitz, Eik; Al-Nawas, Bilal; Tegner, Alexander; Sagheb, Keyvan; Berres, Manfred; Kämmerer, Peer W; Wagner, Wilfried
2016-08-01
Tapered implant designs aim to improve primary stability and implant survival in soft bone. However, respective clinical long-term data are scarce. Therefore, a clinical and radiological evaluation of the long-term success of a transgingival-supracrestal inserted tapered implant system with special emphasis on the influence of augmentation procedures was conducted. In a retrospective study design, all in the Department of Oral and Maxillofacial Surgery of the University Medical Centre, Mainz, Germany, between May 2002 and March 2012, placed tapered implants (Straumann TE®, Basel, Switzerland) were analyzed. In this time period, a total of one hundred ninety-seven tapered implants were inserted in 90 patients. For patients available for clinical recall, success criteria according to Albrektsson and Buser were evaluated. The in situ rate was 96.3% after an average time in situ of 62 ± 31 months. In one hundred twenty-seven sites, bone augmentation procedures were performed. Hereof, 96 sites were sinus augmentation procedures and 31 sites were alveolar ridge augmentations. For patients with sinus augmentation procedures, implant survival was 97.9% and for patients with alveolar ridge augmentations, implant survival was 93.5% after 5 years, indicating a higher implant survival for sinus augmentation, however not statistically different (p = .194). Implant diameter and timing of implant placement had no significant impact on implant survival (p > .05). Mean marginal bone loss was -0.50 ± 1.54 mm for patients receiving maxillary sinus augmentation and -1.16 ± 1.13 mm for patients with alveolar ridge augmentations, indicating a lower marginal bone loss in patients receiving maxillary sinus augmentation (p = .046). Implant success rates ranged between 88% and 92% after a mean follow-up of 6 years. Within the limits of the retrospective character of this study, the tapered soft tissue level implant showed especially in maxillary sinus augmentation promising long-term survival and success rates and a low peri-implant bone resorption compared with the literature. © 2015 Wiley Periodicals, Inc.
Bhardwaj, Upkar; Papadimitrakopoulos, Fotios; Burgess, Diane J.
2008-01-01
A major obstacle to the development of implantable biosensors is the foreign body response (FBR) that results from tissue trauma during implantation and the continuous presence of the implant in the body. The in vivo stability and functionality of biosensors are compromised by damage to sensor components and decreased analyte transport to the sensor. This paper summarizes research undertaken by our group since 2001 to control the FBR toward implanted sensors. Localized and sustained delivery of the anti-inflammatory drug, dexamethasone, and the angiogenic growth factor, vascular endothelial growth factor (VEGF), was utilized to inhibit inflammation as well as fibrosis and provide a stable tissue–device interface without producing systemic adverse effects. The drug-loaded polylactic-co-glycolic acid (PLGA) microspheres were embedded in a polyvinyl alcohol (PVA) hydrogel composite to fabricate a drug-eluting, permeable external coating for implantable devices. The composites were fabricated using the freeze–thaw cycle method and had mechanical properties similar to soft body tissue. Dexamethasone-loaded microsphere/hydrogel composites were able to provide anti-inflammatory protection, preventing the FBR. Moreover, concurrent release of dexamethasone with VEGF induced neoangiogenesis in addition to providing anti-inflammatory protection. Sustained release of dexamethasone is required for the entire sensor lifetime, as a delayed inflammatory response developed after depletion of the drug from the composites. These studies have shown the potential of PLGA microsphere/PVA hydrogel-based composites as drug-eluting external coatings for implantable biosensors. PMID:19885291
Pozhitkov, Alex E.; Daubert, Diane; Brochwicz Donimirski, Ashley; Goodgion, Douglas; Vagin, Mikhail Y.; Leroux, Brian G.; Hunter, Colby M.; Flemmig, Thomas F.; Noble, Peter A.; Bryers, James D.
2015-01-01
Peri-implantitis is an inflammatory disease that results in the destruction of soft tissue and bone around the implant. Titanium implant corrosion has been attributed to the implant failure and cytotoxic effects to the alveolar bone. We have documented the extent of titanium release into surrounding plaque in patients with and without peri-implantitis. An in vitro model was designed to represent the actual environment of an implant in a patient’s mouth. The model uses actual oral microbiota from a volunteer, allows monitoring electrochemical processes generated by biofilms growing on implants and permits control of biocorrosion electrical current. As determined by next generation DNA sequencing, microbial compositions in experiments with the in vitro model were comparable with the compositions found in patients with implants. It was determined that the electrical conductivity of titanium implants was the key factor responsible for the biocorrosion process. The interruption of the biocorrosion current resulted in a 4–5 fold reduction of corrosion. We propose a new design of dental implant that combines titanium in zero oxidation state for osseointegration and strength, interlaid with a nonconductive ceramic. In addition, we propose electrotherapy for manipulation of microbial biofilms and to induce bone healing in peri-implantitis patients. PMID:26461491
Pozhitkov, Alex E; Daubert, Diane; Brochwicz Donimirski, Ashley; Goodgion, Douglas; Vagin, Mikhail Y; Leroux, Brian G; Hunter, Colby M; Flemmig, Thomas F; Noble, Peter A; Bryers, James D
2015-01-01
Peri-implantitis is an inflammatory disease that results in the destruction of soft tissue and bone around the implant. Titanium implant corrosion has been attributed to the implant failure and cytotoxic effects to the alveolar bone. We have documented the extent of titanium release into surrounding plaque in patients with and without peri-implantitis. An in vitro model was designed to represent the actual environment of an implant in a patient's mouth. The model uses actual oral microbiota from a volunteer, allows monitoring electrochemical processes generated by biofilms growing on implants and permits control of biocorrosion electrical current. As determined by next generation DNA sequencing, microbial compositions in experiments with the in vitro model were comparable with the compositions found in patients with implants. It was determined that the electrical conductivity of titanium implants was the key factor responsible for the biocorrosion process. The interruption of the biocorrosion current resulted in a 4-5 fold reduction of corrosion. We propose a new design of dental implant that combines titanium in zero oxidation state for osseointegration and strength, interlaid with a nonconductive ceramic. In addition, we propose electrotherapy for manipulation of microbial biofilms and to induce bone healing in peri-implantitis patients.
Pozzi, Alessandro; Arcuri, Lorenzo; Moy, Peter K
2018-03-01
The growing interest in minimally invasive implant placement and delivery of a prefabricated provisional prosthesis immediately, thus minimizing "time to teeth," has led to the development of numerous 3-dimensional (3D) planning software programs. Given the enhancements associated with fully digital workflows, such as better 3D soft-tissue visualization and virtual tooth rendering, computer-guided implant surgery and immediate function has become an effective and reliable procedure. This article describes how modern implant planning software programs provide a comprehensive digital platform that enables efficient interplay between the surgical and restorative aspects of implant treatment. These new technologies that streamline the overall digital workflow allow transformation of the digital wax-up into a personalized, CAD/CAM-milled provisional restoration. Thus, collaborative digital workflows provide a novel approach for time-efficient delivery of a customized, screw-retained provisional restoration on the day of implant surgery, resulting in improved predictability for immediate function in the partially edentate patient.
[A PhD completed 1. Immediate dental implant placement in the aesthetic zone].
Slagter, K W
2016-05-01
When aesthetics play a role in an extraction, the tendency is to place an implant in the extraction socket immediately, preferably in combination with a temporary crown. This tendency is probably related to evolving social factors: demanding patients who want an instant and attactive result. In 2 randomised clinical trials (total 80 patients) the results of clinical treatment involving immediate implants in the aesthetic zone are investigated. Depending on the size of the bone defect (< 5 or ≥ 5 mm) the number of surgical interventions was reduced from 2 to 1 or from 3 to 2. The treatment result was measured by the following outcome variables: survival rate, changes in hard and soft -peri-implant tissues, aesthetic indecees and patient-satisfaction. The most important conclusion is that immediate placements of implants in the aesthetic zone, results in -outstanding short-term (1-year) results with respect to the outcome variables. If this also leads to good long-term results has yet to be investigated.
Fillers: from the past to the future.
Glogau, Richard G
2012-06-01
Modern medical use of injectable soft-tissue augmentation fillers has evolved from the introduction of bovine collage implants to an array of synthesized materials in the current domestic and foreign markets. The concept of augmentation has moved from simple lines, scars, and wrinkles to revolumizing the aging face. A brief overview of the past, present, and future injectable fillers is presented. Copyright © 2012 Elsevier Inc. All rights reserved.
Lilja, Heidi E; Morrison, Wayne A; Han, Xiao-Lian; Palmer, Jason; Taylor, Caroline; Tee, Richard; Möller, Andreas; Thompson, Erik W; Abberton, Keren M
2013-05-15
Tissue engineering and cell implantation therapies are gaining popularity because of their potential to repair and regenerate tissues and organs. To investigate the role of inflammatory cytokines in new tissue development in engineered tissues, we have characterized the nature and timing of cell populations forming new adipose tissue in a mouse tissue engineering chamber (TEC) and characterized the gene and protein expression of cytokines in the newly developing tissues. EGFP-labeled bone marrow transplant mice and MacGreen mice were implanted with TEC for periods ranging from 0.5 days to 6 weeks. Tissues were collected at various time points and assessed for cytokine expression through ELISA and mRNA analysis or labeled for specific cell populations in the TEC. Macrophage-derived factors, such as monocyte chemotactic protein-1 (MCP-1), appear to induce adipogenesis by recruiting macrophages and bone marrow-derived precursor cells to the TEC at early time points, with a second wave of nonbone marrow-derived progenitors. Gene expression analysis suggests that TNFα, LCN-2, and Interleukin 1β are important in early stages of neo-adipogenesis. Increasing platelet-derived growth factor and vascular endothelial cell growth factor expression at early time points correlates with preadipocyte proliferation and induction of angiogenesis. This study provides new information about key elements that are involved in early development of new adipose tissue.
Lazarides, Alexander L; Whitley, Melodi J; Strasfeld, David B; Cardona, Diana M; Ferrer, Jorge M; Mueller, Jenna L; Fu, Henry L; Bartholf DeWitt, Suzanne; Brigman, Brian E; Ramanujam, Nimmi; Kirsch, David G; Eward, William C
2016-01-01
The treatment of soft tissue sarcoma (STS) generally involves tumor excision with a wide margin. Although advances in fluorescence imaging make real-time detection of cancer possible, removal is limited by the precision of the human eye and hand. Here, we describe a novel pulsed Nd:YAG laser ablation system that, when used in conjunction with a previously described molecular imaging system, can identify and ablate cancer in vivo. Mice with primary STS were injected with the protease-activatable probe LUM015 to label tumors. Resected tissues from the mice were then imaged and treated with the laser using the paired fluorescence-imaging/ laser ablation device, generating ablation clefts with sub-millimeter precision and minimal underlying tissue damage. Laser ablation was guided by fluorescence to target tumor tissues, avoiding normal structures. The selective ablation of tumor implants in vivo improved recurrence-free survival after tumor resection in a cohort of 14 mice compared to 12 mice that received no ablative therapy. This prototype system has the potential to be modified so that it can be used during surgery to improve recurrence-free survival in patients with cancer.
Rare finding of Eustachian tube calcifications with cone-beam computed tomography.
Syed, Ali Z; Hawkins, Anna; Alluri, Leela Subashini; Jadallah, Buthainah; Shahid, Kiran; Landers, Michael; Assaf, Hussein M
2017-12-01
Soft tissue calcification is a pathological condition in which calcium and phosphate salts are deposited in the soft tissue organic matrix. This study presents an unusual calcification noted in the cartilaginous portion of the Eustachian tube. A 67-year-old woman presented for dental treatment, specifically for implant placement, and cone-beam computed tomography (CBCT) was performed. The CBCT scan was reviewed by a board-certified oral and maxillofacial radiologist and revealed incidental findings of 2 distinct calcifications in the cartilaginous portion of the Eustachian tube. To the authors' knowledge, no previous study has reported the diagnosis of Eustachian tube calcification using CBCT. This report describes an uncommon variant of Eustachian tube calcification, which has a significant didactic value because such cases are seldom illustrated either in textbooks or in the literature. This case once again underscores the importance of having CBCT scans evaluated by a board-certified oral and maxillofacial radiologist.
Catastrophic metallosis after tumoral knee prosthesis failure: A case report.
La Verde, Luca; Fenga, Domenico; Spinelli, Maria Silvia; Campo, Francesco Rosario; Florio, Michela; Rosa, Michele Attilio
2017-01-01
Metallosis is a condition characterized by an infiltration of periprosthetic soft tissues and bone by metallic debris resulting from wear or failure of joint arthroplasties. Authors describe a case of a 45-year-old man treated for an osteosarcoma of the distal femur with a modular prosthesis when he was 18 years old, he developed massive metallosis with skin dyspigmentation after 17 years. His medical\\surgical history was remarkable for a left tumoral knee prosthesis implanted 21 years ago. Two years before revision, the patient had a car accident with a two-points prosthesis breakage and despite the surgeon's advice, the patient refused surgery. In two years, prosthesis malfunction caused a progressive catastrophic soft tissues infiltration of metallic debris. Authors suggest that if prosthesis fracture is detected, revision surgery should be attempted as earlier as possible. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Alveolar distraction osteogenesis: revive and restore the native bone.
Sant, Sumedha; Jagtap, Amit
2009-12-01
In prosthodontics, knife-edge bony alveolar ridges can cause a problem in their rehabilitation. The distraction osteogenesis process raises the medullary component of the alveolus, allowing the labial plate of the existing natural bone to be displaced. This process involves mobilization, transport, and fixation of a healthy segment of bone adjacent to the deficient site. It entails use of the gradual controlled displacement of surgically created fractures, which results in simultaneous expansion of soft tissue and bone volume. A mechanical device, the alveolar distraction device, is used for this purpose. This modality of treatment can be used in implant dentistry cases for rehabilitation of resorbed ridges. The objective of this overview is to explain this procedure wherein the alveolar housing, including the osseous and soft-tissue components, is enlarged in a single, simultaneous process, which makes creation of an appropriate alveolar morphology possible.
Takahashi, Hironobu; Wang, Yuwei; Grainger, David W
2010-11-01
Fibrous encapsulation of surgically implanted devices is associated with elevated proliferation and activation of fibroblasts in tissues surrounding these implants, frequently causing foreign body complications. Here we test the hypothesis that inhibition of the expression of mammalian target of rapamycin (mTOR) in fibroblasts can mitigate the soft tissue implant foreign body response by suppressing fibrotic responses around implants. In this study, mTOR was knocked down using small interfering RNA (siRNA) conjugated with branched polyethylenimine (bPEI) in fibroblastic lineage cells in serum-based cell culture as shown by both gene and protein analysis. This mTOR knock-down led to an inhibition in fibroblast proliferation by 70% and simultaneous down-regulation in the expression of type I collagen in fibroblasts in vitro. These siRNA/bPEI complexes were released from poly(ethylene glycol) (PEG)-based hydrogel coatings surrounding model polymer implants in a subcutaneous rodent model in vivo. No significant reduction in fibrous capsule thickness and mTOR expression in the foreign body capsules were observed. The siRNA inefficacy in this in vivo implant model was attributed to siRNA dosing limitations in the gel delivery system, and lack of targeting ability of the siRNA complex specifically to fibroblasts. While in vitro data supported mTOR knock-down in fibroblast cultures, in vivo siRNA delivery must be further improved to produce clinically relevant effects on fibrotic encapsulation around implants. Copyright © 2010 Elsevier B.V. All rights reserved.
Ma, Ning; Li, Wei-Ran; Chen, Xiao-Hong; Zheng, Xu
2016-08-01
To compare the treatment effects in patients with maxillary protrusion between implant anchorage and traditional intraoral anchorage. Thirty patients with maxillary protrusion treated with bilateral maxillary first premolars extractions and high anchorage were selected. They were randomly divided into implant anchorage group and traditional intraoral anchorage group. Each group had 15 cases. The casts and the cephalograms were obtained before treatment (T1) and after treatment (T2). Three-dimensional model analysis was used to compare the teeth movements between the two groups and cephalometric analysis was used to compare the changes of skeletal and soft tissues. The differences were analyzed with SPSS 17.0 software package. In the implant anchorage group, the upper central incisors were retracted by (6.661±1.328) mm and intruded by (0.129±1.815) mm. In the traditional intraoral anchorage group, the upper central incisors were retracted by (5.788±2.009) mm and extruded by (2.623±1.776) mm. There was no significant difference between the two groups in sagittal movement (P>0.05), but there was significant difference in vertical movement (P<0.05). In the implant anchorage group, the upper first molars were protracted by (0.608±1.045) mm, intruded by (0.608±1.045) mm and moved palatally by (0.477±0.904) mm. In the traditional intraoral anchorage group, the upper first molars were protracted by (1.503±0.945) mm, extruded by (0.072±0.690) mm and moved palatally by (0.883±0.752)mm. There was significant difference between the two groups in sagittal movement and vertical movement (P<0.05), but there was no significant difference in horizontal movement(P>0.05). There was no significant difference between the two groups in the changes of cephalometric measurements of skeletal and soft tissues (P>0.05). Implant anchorage may be superior in vertical control of the maxillary incisors and also superior in sagittal and vertical control of the maxillary molars to traditional intraoral anchorage during management of maxillary protrusion.
Intraoral ultrasonography: development of a specific high-frequency probe and clinical pilot study.
Salmon, Benjamin; Le Denmat, Dominique
2012-04-01
Although ultrasonography is a non-invasive, inexpensive and painless diagnostic tool for soft tissue imaging, this technique is not currently used for oral exploration. Therefore, we developed a 25-MHz high-frequency ultrasound probe, specially designed for intraoral applications. This paper aims to present clinical intraoral ultrasound images actually interpretable, in order to identify the relevant applications of this novel tool and to design future oral studies. Two independent radiologists performed ultrasound examinations on three healthy volunteers. All the teeth were explored on the lingual and buccal sides (162 samples) to evaluate the ergonomics of the system and the visualisation of anatomic structures. Osseointegrated dental implants and a mucocele were also scanned. At the gingivodental junction of the maxillary and mandibular teeth, the device clearly identifies the tooth surfaces, the alveolar bone reflection with its surrounding subepithelial connective tissue of the gingiva and the gingival epithelia. The bone level and the thickness of soft tissue around the implant are measurable on the buccal and lingual sides. Therefore, intraoral ultrasonography provides additional morphological information that is not accessible by conventional dental x-rays. We propose a novel diagnostic tool that explores the biological width and is able to define the thin or thick nature of the gums. Moreover, intraoral ultrasonography may help to monitor precancerous lesions. This promising device requires large-scale clinical studies to determine whether it should remain a research tool or be used as a diagnostic tool for daily dental practice.
Lingual orthodontics and forced eruption: a means for osseous and tissue regeneration.
Paolone, Maria Giacinta; Kaitsas, Roberto; Paolone, Gaetano; Kaitsas, Vassilios
2008-01-01
An hopeless upper central incisor was subjected to forced eruption in order to improve and develop the implant site by distraction of the periodontal ligament-alveolar bone complex. The orthodontic extrusion was carried out with two aesthetic approaches: lingual orthodontics and a composite resin 2-2 veneer pontic. The first part of the extrusion was realized with lingual orthodontics alone, then, when the crown had been remodelled in its greatest part and the aesthetics was no more acceptable to the patient a composite resin 2-2 veneer pontic was bonded to the vestibular side of the other three incisors to mimetise the extruded tooth and to be anchorage to the lingual mechanics. The orthodontic preparation of the implant site allowed the correction of the periodontal defect due to the fracture, the enhancement of the alveolar bone and the soft tissue remodelling.
Uckermann, Ortrud; Sitoci-Ficici, Kerim H.; Later, Robert; Beiermeister, Rudolf; Doberenz, Falko; Gelinsky, Michael; Leipnitz, Elke; Schackert, Gabriele; Koch, Edmund; Sablinskas, Valdas; Steiner, Gerald; Kirsch, Matthias
2015-01-01
Spinal cord injury (SCI) induces complex biochemical changes, which result in inhibition of nervous tissue regeneration abilities. In this study, Fourier-transform infrared (FT-IR) spectroscopy was applied to assess the outcomes of implants made of a novel type of non-functionalized soft calcium alginate hydrogel in a rat model of spinal cord hemisection (n = 28). Using FT-IR spectroscopic imaging, we evaluated the stability of the implants and the effects on morphology and biochemistry of the injured tissue one and six months after injury. A semi-quantitative evaluation of the distribution of lipids and collagen showed that alginate significantly reduced injury-induced demyelination of the contralateral white matter and fibrotic scarring in the chronic state after SCI. The spectral information enabled to detect and localize the alginate hydrogel at the lesion site and proved its long-term persistence in vivo. These findings demonstrate a positive impact of alginate hydrogel on recovery after SCI and prove FT-IR spectroscopic imaging as alternative method to evaluate and optimize future SCI repair strategies. PMID:26559822
Puzio, Monika; Błaszczyszyn, Artur; Hadzik, Jakub; Dominiak, Marzena
2018-05-01
A comparative, ultrasound evaluation of the thickness of keratinized mucosa (TKT) around implants one year after gingival augmentation (GA) by means of a connective tissue graft (CTG) and the xenogeneic collagen matrix (CMX). A total of 75 bone level tapered implants (Conelog ® Camlog) were inserted in 57 patients in the aesthetic area of both jaws. The patients were divided into 3 groups: control group I- without GA; group II- GA 3 months before implantation, and group III- GA 3 months after implantation. Groups II and III were divided into two subgroups depends on type of material used for GA: (a) CMX (Mucograft ® , Geistlich Pharma AG) and (b) CTG. The patients underwent a clinical and ultrasound examination before, then after 3 and 12 months following GA respectively to evaluate TKT at two points using ultrasound equipment (Pirop ® , Echoson). Point 1 was considered to be in the middle of the line connecting the cemento-enamel junction (CEJ) to the adjacent teeth, and point 2 on the mucogingival junction (MGJ). Three months after GA, the highest increase in gingival thickness was noted in group IIIb (point 1 - 0.95mm, 2 - 1.01mm). However, 12 months after GA the highest gingival thickness was observed in group IIb (point 1 - 1.76mm, 2 - 1.36m) and next IIIb (point 1 - 1.52mm, 2 - 1.15mm). Both CTG and Geistlich Mucograft ® increased TKT, but higher values were noted using CTG augmentation before implantation. An ultrasonic device can be used as a non-invasive, reliable, and reproducible method for evaluating TKT. Copyright © 2017 Elsevier GmbH. All rights reserved.
Lorenz, Jonas; Korzinskas, Tadas; Chia, Poju; Maawi, Sarah Al; Eichler, Katrin; Sader, Robert A; Ghanaati, Shahram
2018-02-01
The present prospective randomized split-mouth trial reports on the 3-year clinical and radiological follow-up investigation of implants placed 7 months after sinus augmentation with 2 different bone substitute materials. The aim of the study was to complete the histologic observation of cellular reactions by analyses of the implants and the volumetric changes of the augmented bone substitute materials. A sinus augmentation split-mouth trial was performed in 14 patients with the synthetic bone substitute material Nanobone (NB) and the xenogeneic Bio-Oss (BO). Changes in volume and density of the augmented biomaterials were investigated by analysis of computed tomography scans, taken immediately after augmentation and after 7 months. Clinical implant parameters were assessed after 3 years of loading. Both bone substitute materials underwent nonsignificant volume reduction and significant increase in bone density over an integration period of 7 months. No significant differences concerning volume and bone density were observed between the groups. Three years after loading, 51 of 53 implants were in situ with no peri-implant infections, and only a few soft-tissue variations were present. The present prospective randomized study showed that no differences could be observed clinically and radiologically. Accordingly, it seems that both biomaterials, independent of their physicochemical composition, enable clinical success and long-time stability for dental implants. Interestingly, the histological results showed distinct differences in cellular reactions: While the xenogeneic BO induced a mild tissue reaction with only few multinucleated giant cells and comparably low vascularization, the synthetic NB induced a multinucleated giant cell-triggered tissue reaction with an increase of vascularization. Thus, the present study showed that a combination analysis-histological, clinical, and radiological-is necessary for a detailed assessment of a biomaterial's quality for clinical application.
Dai, Wen-yong; Zhou, Guo-xing; Zhang, Xiao-zhen; Zhao, Yi; Wang, Jie; Yang, Yi; Zhu, Zhi-jun; Tang, Chun-bo
2014-08-01
To offer individualized restorative strategies for patients receiving dental implants in the anterior esthetic zone but with inappropriate available conditions and evaluate the clinical outcomes. Forty-six patients with 58 implants were recruited for the study in accordance with the criteria and received individualized implant prostheses in the anterior esthetic zone. The patients were followed up for 3-24 months, and the clinical outcomes were evaluated by pink and white esthetic scores (PES/WES). The patients were from 18 to 69 years old, and followed up for 12.6 months in average. According to the third month follow-up esthetic scores, for PES, 1.72% of the patients got low scores, 44.83% got medium scores and 53.45% got high scores; For WES, 0% got low scores, 20.69% got medium scores and 79.31% got high scores. No implant failure or peri-implantitis occurred. Individualized restorative designs for implants in the esthetic zone can effectively improve the appearance of the prostheses which originally have no appropriate available space. Close follow-up and monitoring of the peri-implant soft tissue and proper oral hygiene instructions are important to ensure the conditions of the prostheses.
A lateral approach for sinus elevation using PRGF technology.
Anitua, Eduardo; Prado, Roberto; Orive, Gorka
2009-10-01
A lateral approach for sinus elevation using plasma rich in growth factors (PRGF) technology is described. The long-term survival of dental implants installed following a two-stage procedure after sinus elevation using this procedure is reported, using implant loss as the outcome variable. A retrospective cohort study design was used. Eighteen patients received 43 implants (BTI implants, Biotechnology Institute, Vitoria, Spain) with sinus floor elevation. All patients presented a residual bone height of class D (1-3 mm). Implants were installed using a low-speed drilling procedure (50 rpm) without irrigation. Finally, the histological and histomorphometric evaluation of eight samples from PRGF grafted sinus involved in the study was carried out 5-6 months posttreatment. The overall survival rate of dental implants was 100%. The mean follow-up period for all implants was 33 +/- 7 months ranging from 24 to 44 months. In addition, the histomorphometrical evaluation of the samples evidenced a 25.24 +/- 4.62% of vital newly formed bone, 50.31 +/- 15.56% of soft connective tissue, and the remaining 24.46 +/- 12.79% of bovine anorganic bone. Based on these results, this new approach for sinus elevation and implant installation using PRGF technology can be considered safe, simple, effective, and predictable.
Guided bone regeneration using individualized ceramic sheets.
Malmström, J; Anderud, J; Abrahamsson, P; Wälivaara, D-Å; Isaksson, S G; Adolfsson, E
2016-10-01
Guided bone regeneration (GBR) describes the use of membranes to regenerate bony defects. A membrane for GBR needs to be biocompatible, cell-occlusive, non-toxic, and mouldable, and possess space-maintaining properties including stability. The purpose of this pilot study was to describe a new method of GBR using individualized ceramic sheets to perfect bone regeneration prior to implant placement; bone regeneration was assessed using traditional histology and three-dimensional (3D) volumetric changes in the bone and soft tissue. Three patients were included. After full-thickness flap reflection, the individualized ceramic sheets were fixed. The sites were left to heal for 7 months. All patients were evaluated preoperatively and at 7 months postoperative using cone beam computed tomography and 3D optical equipment. Samples of the regenerated bone and soft tissue were collected and analyzed. The bone regenerated in the entire interior volume of all sheets. Bone biopsies revealed newly formed trabecular bone with a lamellar structure. Soft tissue biopsies showed connective tissue with no signs of an inflammatory response. This was considered to be newly formed periosteum. Thus ceramic individualized sheets can be used to regenerate large volumes of bone in both vertical and horizontal directions independent of the bone defect and with good biological acceptance of the material. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Elastomeric and soft conducting microwires for implantable neural interfaces
Kolarcik, Christi L.; Luebben, Silvia D.; Sapp, Shawn A.; Hanner, Jenna; Snyder, Noah; Kozai, Takashi D.Y.; Chang, Emily; Nabity, James A.; Nabity, Shawn T.; Lagenaur, Carl F.; Cui, X. Tracy
2015-01-01
Current designs for microelectrodes used for interfacing with the nervous system elicit a characteristic inflammatory response that leads to scar tissue encapsulation, electrical insulation of the electrode from the tissue and ultimately failure. Traditionally, relatively stiff materials like tungsten and silicon are employed which have mechanical properties several orders of magnitude different from neural tissue. This mechanical mismatch is thought to be a major cause of chronic inflammation and degeneration around the device. In an effort to minimize the disparity between neural interface devices and the brain, novel soft electrodes consisting of elastomers and intrinsically conducting polymers were fabricated. The physical, mechanical and electrochemical properties of these materials were extensively characterized to identify the formulations with the optimal combination of parameters including Young’s modulus, elongation at break, ultimate tensile strength, conductivity, impedance and surface charge injection. Our final electrode has a Young’s modulus of 974 kPa which is five orders of magnitude lower than tungsten and significantly lower than other polymer-based neural electrode materials. In vitro cell culture experiments demonstrated the favorable interaction between these soft materials and neurons, astrocytes and microglia, with higher neuronal attachment and a two-fold reduction in inflammatory microglia attachment on soft devices compared to stiff controls. Surface immobilization of neuronal adhesion proteins on these microwires further improved the cellular response. Finally, in vivo electrophysiology demonstrated the functionality of the elastomeric electrodes in recording single unit activity in the rodent visual cortex. The results presented provide initial evidence in support of the use of soft materials in neural interface applications. PMID:25993261
NASA Astrophysics Data System (ADS)
Sajnóg, Adam; Hanć, Anetta; Makuch, Krzysztof; Koczorowski, Ryszard; Barałkiewicz, Danuta
2016-11-01
Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was used for in-situ quantitative analysis of oral mucosa of patients before and after implantation with titanium implants and a closing screw based on Ti6Al4V alloy. Two calibration strategies were applied, both were based on matrix matched solid standards with analytes addition. A novel approach was the application of powdered egg white proteins as a matrix material which have a similar composition to the examined tissue. In the another approach, certified reference material Bovine Muscle ERM-BB184 was used. The isotope 34S was found to be the most appropriate as an internal standard since it is homogenously distributed in the examined tissues and resulted in lower relative standard deviation values of signal of analytes of interest. Other isotopes (13C, 26Mg, 43Ca) were also evaluated as potential internal standards. The analytical performance parameters and microwave digestion of solid standards followed by solution nebulization ICP-MS analysis proved that both calibration methods are fit for their intended purpose. The LA-ICP-MS analysis on the surface of tissues after the implantation process revealed an elevated content of elements in comparison to the control group. Analytes are distributed inhomogeneously and display local maximal content of Ti up to ca. 900 μg g- 1, Al up to ca. 760 μg g- 1 and for V up to 160 μg g- 1.
Maia, Luciana P; Reino, Danilo M; Muglia, Valdir A; de Souza, Sérgio L S; Palioto, Daniela B; Novaes, Arthur B
2015-01-01
Soft tissues and buccal bone plate remodeling after immediate implantation in sockets with thin buccal bone, using the flapless approach with or without bone graft into the buccal gap, was compared between sites with thin and normal gingiva. Eight dogs had the gingiva of one side of the mandible thinned, the mandibular premolars were extracted without flaps, and 4 implants were installed in each side, positioned 1.5 mm from the buccal bone. The sites were randomly assigned into: TG (test group) = thin gingiva; TG + GM (TG with grafting material); CG (control group) = normal gingiva; and CG + GM (CG with grafting material). Buccal bone thickness (BBT), thickness of keratinized tissue (TKT), alveolar thickness (AT), gingival recession (GR), and probing depth (PD) were clinically evaluated. Within 12 weeks the dogs were sacrificed and the samples were analyzed by micro-computerized tomography. A thin BBT was observed in all the dogs. The presurgical procedures reduced TKT in the test group, with minimal changes of the AT. There were no statistically significant differences among the groups for the clinical parameters and the tomographic analysis showed similar linear and tri-dimensional bone reduction in all the groups. The thickness of the buccal bone was a fundamental factor in buccal bone plate resorption, even with flapless implantation. The decrease in gingival thickness or the addition of a biomaterial in the gap did not influence the results. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Hof, M; Pommer, B; Strbac, G D; Sütö, D; Watzek, G; Zechner, W
2013-08-01
Autologous bone augmentation to rebuild compromised alveolar ridge contour prior to implant placement allows for favorable three-dimensional implant positioning to achieve optimum implant esthetics. The aim of the present study was to evaluate peri-implant soft tissue conditions around single-tooth implants following bone grafts in the esthetic zone of the maxilla. Sixty patients underwent autologous bone augmentation of deficient maxillary sites prior to placement of 85 implants in the esthetic zone. In case of multiple implants per patient, one implant was randomly selected. Objective evaluation of 60 single-tooth implants was performed using the Pink-Esthetic-Score (PES) and Papilla Index (PI) and supplemented by subjective patient evaluation, as well as clinical and radiologic examination. Objective ratings of implant esthetics were satisfactory (median PES: 11, median PI: 2) and significantly correlated with high patient satisfaction (mean VAS score: 80%). Both esthetic indices demonstrated respectable levels of inter- as well as intra-observer agreement. Poor implant esthetics (low PES and PI ratings) were significantly associated with increased anatomic crown height, while no influence of horizontal implant-tooth distance could be found. The present investigation indicates that favorable esthetic results may be achieved in the augmented anterior maxilla. However, bony reconstruction of compromised alveolar ridges does not guarantee optimum implant esthetics. © 2011 John Wiley & Sons A/S.
Schnabl, Johannes; Glueckert, Rudolf; Feuchtner, Gudrun; Recheis, Wolfgang; Potrusil, Thomas; Kuhn, Volker; Wolf-Magele, Astrid; Riechelmann, Herbert; Sprinzl, Georg M
2012-04-01
Currently, no large animal model exists for surgical-experimental exploratory analysis of implantable hearing devices. In a histomorphometric study, we sought to investigate whether sheep or pig cochleae are suitable for this purpose and whether device implantation is feasible. Skulls of pig and sheep cadavers were examined using high-resolution 128-slice computed tomography (CT) to study anatomic relationships. A cochlear implant and an active middle ear implant could be successfully implanted into the sheep's inner and middle ear, respectively. Correct device placement was verified by CT and histology. The cochlear anatomy of the sheep was further studied by micro-CT and histology. Our investigations indicate that the sheep is a suitable animal model for implantation of implantable hearing devices. The implantation of the devices was successfully performed by access through a mastoidectomy. The histologic, morphologic, and micro-CT study of the sheep cochlea showed that it is highly similar to the human cochlea. The temporal bone of the pig was not suitable for these microsurgical procedures because the middle and inner ear were not accessible owing to distinct soft and fatty tissue coverage of the mastoid. The sheep is an appropriate large animal model for experimental studies with implantable hearing devices, whereas the pig is not.