Sample records for software quality metrics

  1. Software metrics: Software quality metrics for distributed systems. [reliability engineering

    NASA Technical Reports Server (NTRS)

    Post, J. V.

    1981-01-01

    Software quality metrics was extended to cover distributed computer systems. Emphasis is placed on studying embedded computer systems and on viewing them within a system life cycle. The hierarchy of quality factors, criteria, and metrics was maintained. New software quality factors were added, including survivability, expandability, and evolvability.

  2. Evaluating software development characteristics: Assessment of software measures in the Software Engineering Laboratory. [reliability engineering

    NASA Technical Reports Server (NTRS)

    Basili, V. R.

    1981-01-01

    Work on metrics is discussed. Factors that affect software quality are reviewed. Metrics is discussed in terms of criteria achievements, reliability, and fault tolerance. Subjective and objective metrics are distinguished. Product/process and cost/quality metrics are characterized and discussed.

  3. Establishing Qualitative Software Metrics in Department of the Navy Programs

    DTIC Science & Technology

    2015-10-29

    dedicated to provide the highest quality software to its users. In doing, there is a need for a formalized set of Software Quality Metrics . The goal...of this paper is to establish the validity of those necessary Quality metrics . In our approach we collected the data of over a dozen programs...provide the necessary variable data for our formulas and tested the formulas for validity. Keywords: metrics ; software; quality I. PURPOSE Space

  4. Establishing Quantitative Software Metrics in Department of the Navy Programs

    DTIC Science & Technology

    2016-04-01

    13 Quality to Metrics Dependency Matrix...11 7. Quality characteristics to metrics dependecy matrix...In accomplishing this goal, a need exists for a formalized set of software quality metrics . This document establishes the validity of those necessary

  5. Software Quality Assurance Metrics

    NASA Technical Reports Server (NTRS)

    McRae, Kalindra A.

    2004-01-01

    Software Quality Assurance (SQA) is a planned and systematic set of activities that ensures conformance of software life cycle processes and products conform to requirements, standards and procedures. In software development, software quality means meeting requirements and a degree of excellence and refinement of a project or product. Software Quality is a set of attributes of a software product by which its quality is described and evaluated. The set of attributes includes functionality, reliability, usability, efficiency, maintainability, and portability. Software Metrics help us understand the technical process that is used to develop a product. The process is measured to improve it and the product is measured to increase quality throughout the life cycle of software. Software Metrics are measurements of the quality of software. Software is measured to indicate the quality of the product, to assess the productivity of the people who produce the product, to assess the benefits derived from new software engineering methods and tools, to form a baseline for estimation, and to help justify requests for new tools or additional training. Any part of the software development can be measured. If Software Metrics are implemented in software development, it can save time, money, and allow the organization to identify the caused of defects which have the greatest effect on software development. The summer of 2004, I worked with Cynthia Calhoun and Frank Robinson in the Software Assurance/Risk Management department. My task was to research and collect, compile, and analyze SQA Metrics that have been used in other projects that are not currently being used by the SA team and report them to the Software Assurance team to see if any metrics can be implemented in their software assurance life cycle process.

  6. A software quality model and metrics for risk assessment

    NASA Technical Reports Server (NTRS)

    Hyatt, L.; Rosenberg, L.

    1996-01-01

    A software quality model and its associated attributes are defined and used as the model for the basis for a discussion on risk. Specific quality goals and attributes are selected based on their importance to a software development project and their ability to be quantified. Risks that can be determined by the model's metrics are identified. A core set of metrics relating to the software development process and its products is defined. Measurements for each metric and their usability and applicability are discussed.

  7. Semantic Metrics for Analysis of Software

    NASA Technical Reports Server (NTRS)

    Etzkorn, Letha H.; Cox, Glenn W.; Farrington, Phil; Utley, Dawn R.; Ghalston, Sampson; Stein, Cara

    2005-01-01

    A recently conceived suite of object-oriented software metrics focus is on semantic aspects of software, in contradistinction to traditional software metrics, which focus on syntactic aspects of software. Semantic metrics represent a more human-oriented view of software than do syntactic metrics. The semantic metrics of a given computer program are calculated by use of the output of a knowledge-based analysis of the program, and are substantially more representative of software quality and more readily comprehensible from a human perspective than are the syntactic metrics.

  8. Understanding Acceptance of Software Metrics--A Developer Perspective

    ERIC Educational Resources Information Center

    Umarji, Medha

    2009-01-01

    Software metrics are measures of software products and processes. Metrics are widely used by software organizations to help manage projects, improve product quality and increase efficiency of the software development process. However, metrics programs tend to have a high failure rate in organizations, and developer pushback is one of the sources…

  9. Software metrics: The key to quality software on the NCC project

    NASA Technical Reports Server (NTRS)

    Burns, Patricia J.

    1993-01-01

    Network Control Center (NCC) Project metrics are captured during the implementation and testing phases of the NCCDS software development lifecycle. The metrics data collection and reporting function has interfaces with all elements of the NCC project. Close collaboration with all project elements has resulted in the development of a defined and repeatable set of metrics processes. The resulting data are used to plan and monitor release activities on a weekly basis. The use of graphical outputs facilitates the interpretation of progress and status. The successful application of metrics throughout the NCC project has been instrumental in the delivery of quality software. The use of metrics on the NCC Project supports the needs of the technical and managerial staff. This paper describes the project, the functions supported by metrics, the data that are collected and reported, how the data are used, and the improvements in the quality of deliverable software since the metrics processes and products have been in use.

  10. Validation of a Quality Management Metric

    DTIC Science & Technology

    2000-09-01

    quality management metric (QMM) was used to measure the performance of ten software managers on Department of Defense (DoD) software development programs. Informal verification and validation of the metric compared the QMM score to an overall program success score for the entire program and yielded positive correlation. The results of applying the QMM can be used to characterize the quality of software management and can serve as a template to improve software management performance. Future work includes further refining the QMM, applying the QMM scores to provide feedback

  11. Getting started on metrics - Jet Propulsion Laboratory productivity and quality

    NASA Technical Reports Server (NTRS)

    Bush, M. W.

    1990-01-01

    A review is presented to describe the effort and difficulties of reconstructing fifteen years of JPL software history. In 1987 the collection and analysis of project data were started with the objective of creating laboratory-wide measures of quality and productivity for software development. As a result of this two-year Software Product Assurance metrics study, a rough measurement foundation for software productivity and software quality, and an order-of-magnitude quantitative baseline for software systems and subsystems are now available.

  12. Pragmatic quality metrics for evolutionary software development models

    NASA Technical Reports Server (NTRS)

    Royce, Walker

    1990-01-01

    Due to the large number of product, project, and people parameters which impact large custom software development efforts, measurement of software product quality is a complex undertaking. Furthermore, the absolute perspective from which quality is measured (customer satisfaction) is intangible. While we probably can't say what the absolute quality of a software product is, we can determine the relative quality, the adequacy of this quality with respect to pragmatic considerations, and identify good and bad trends during development. While no two software engineers will ever agree on an optimum definition of software quality, they will agree that the most important perspective of software quality is its ease of change. We can call this flexibility, adaptability, or some other vague term, but the critical characteristic of software is that it is soft. The easier the product is to modify, the easier it is to achieve any other software quality perspective. This paper presents objective quality metrics derived from consistent lifecycle perspectives of rework which, when used in concert with an evolutionary development approach, can provide useful insight to produce better quality per unit cost/schedule or to achieve adequate quality more efficiently. The usefulness of these metrics is evaluated by applying them to a large, real world, Ada project.

  13. Integrating automated support for a software management cycle into the TAME system

    NASA Technical Reports Server (NTRS)

    Sunazuka, Toshihiko; Basili, Victor R.

    1989-01-01

    Software managers are interested in the quantitative management of software quality, cost and progress. An integrated software management methodology, which can be applied throughout the software life cycle for any number purposes, is required. The TAME (Tailoring A Measurement Environment) methodology is based on the improvement paradigm and the goal/question/metric (GQM) paradigm. This methodology helps generate a software engineering process and measurement environment based on the project characteristics. The SQMAR (software quality measurement and assurance technology) is a software quality metric system and methodology applied to the development processes. It is based on the feed forward control principle. Quality target setting is carried out before the plan-do-check-action activities are performed. These methodologies are integrated to realize goal oriented measurement, process control and visual management. A metric setting procedure based on the GQM paradigm, a management system called the software management cycle (SMC), and its application to a case study based on NASA/SEL data are discussed. The expected effects of SMC are quality improvement, managerial cost reduction, accumulation and reuse of experience, and a highly visual management reporting system.

  14. The Effects of Development Team Skill on Software Product Quality

    NASA Technical Reports Server (NTRS)

    Beaver, Justin M.; Schiavone, Guy A.

    2006-01-01

    This paper provides an analysis of the effect of the skill/experience of the software development team on the quality of the final software product. A method for the assessment of software development team skill and experience is proposed, and was derived from a workforce management tool currently in use by the National Aeronautics and Space Administration. Using data from 26 smallscale software development projects, the team skill measures are correlated to 5 software product quality metrics from the ISO/IEC 9126 Software Engineering Product Quality standard. in the analysis of the results, development team skill is found to be a significant factor in the adequacy of the design and implementation. In addition, the results imply that inexperienced software developers are tasked with responsibilities ill-suited to their skill level, and thus have a significant adverse effect on the quality of the software product. Keywords: software quality, development skill, software metrics

  15. Software quality: Process or people

    NASA Technical Reports Server (NTRS)

    Palmer, Regina; Labaugh, Modenna

    1993-01-01

    This paper will present data related to software development processes and personnel involvement from the perspective of software quality assurance. We examine eight years of data collected from six projects. Data collected varied by project but usually included defect and fault density with limited use of code metrics, schedule adherence, and budget growth information. The data are a blend of AFSCP 800-14 and suggested productivity measures in Software Metrics: A Practioner's Guide to Improved Product Development. A software quality assurance database tool, SQUID, was used to store and tabulate the data.

  16. Automating Software Design Metrics.

    DTIC Science & Technology

    1984-02-01

    INTRODUCTION 1 ", ... 0..1 1.2 HISTORICAL PERSPECTIVE High quality software is of interest to both the software engineering com- munity and its users. As...contributions of many other software engineering efforts, most notably [MCC 77] and [Boe 83b], which have defined and refined a framework for quantifying...AUTOMATION OF DESIGN METRICS Software metrics can be useful within the context of an integrated soft- ware engineering environment. The purpose of this

  17. The Assignment of Scale to Object-Oriented Software Measures

    NASA Technical Reports Server (NTRS)

    Neal, Ralph D.; Weistroffer, H. Roland; Coppins, Richard J.

    1997-01-01

    In order to improve productivity (and quality), measurement of specific aspects of software has become imperative. As object oriented programming languages have become more widely used, metrics designed specifically for object-oriented software are required. Recently a large number of new metrics for object- oriented software has appeared in the literature. Unfortunately, many of these proposed metrics have not been validated to measure what they purport to measure. In this paper fifty (50) of these metrics are analyzed.

  18. State of the art metrics for aspect oriented programming

    NASA Astrophysics Data System (ADS)

    Ghareb, Mazen Ismaeel; Allen, Gary

    2018-04-01

    The quality evaluation of software, e.g., defect measurement, gains significance with higher use of software applications. Metric measurements are considered as the primary indicator of imperfection prediction and software maintenance in various empirical studies of software products. However, there is no agreement on which metrics are compelling quality indicators for novel development approaches such as Aspect Oriented Programming (AOP). AOP intends to enhance programming quality, by providing new and novel constructs for the development of systems, for example, point cuts, advice and inter-type relationships. Hence, it is not evident if quality pointers for AOP can be derived from direct expansions of traditional OO measurements. Then again, investigations of AOP do regularly depend on established coupling measurements. Notwithstanding the late reception of AOP in empirical studies, coupling measurements have been adopted as useful markers of flaw inclination in this context. In this paper we will investigate the state of the art metrics for measurement of Aspect Oriented systems development.

  19. Requirement Metrics for Risk Identification

    NASA Technical Reports Server (NTRS)

    Hammer, Theodore; Huffman, Lenore; Wilson, William; Rosenberg, Linda; Hyatt, Lawrence

    1996-01-01

    The Software Assurance Technology Center (SATC) is part of the Office of Mission Assurance of the Goddard Space Flight Center (GSFC). The SATC's mission is to assist National Aeronautics and Space Administration (NASA) projects to improve the quality of software which they acquire or develop. The SATC's efforts are currently focused on the development and use of metric methodologies and tools that identify and assess risks associated with software performance and scheduled delivery. This starts at the requirements phase, where the SATC, in conjunction with software projects at GSFC and other NASA centers is working to identify tools and metric methodologies to assist project managers in identifying and mitigating risks. This paper discusses requirement metrics currently being used at NASA in a collaborative effort between the SATC and the Quality Assurance Office at GSFC to utilize the information available through the application of requirements management tools.

  20. The Validation by Measurement Theory of Proposed Object-Oriented Software Metrics

    NASA Technical Reports Server (NTRS)

    Neal, Ralph D.

    1996-01-01

    Moving software development into the engineering arena requires controllability, and to control a process, it must be measurable. Measuring the process does no good if the product is not also measured, i.e., being the best at producing an inferior product does not define a quality process. Also, not every number extracted from software development is a valid measurement. A valid measurement only results when we are able to verify that the number is representative of the attribute that we wish to measure. Many proposed software metrics are used by practitioners without these metrics ever having been validated, leading to costly but often useless calculations. Several researchers have bemoaned the lack of scientific precision in much of the published software measurement work and have called for validation of software metrics by measurement theory. This dissertation applies measurement theory to validate fifty proposed object-oriented software metrics.

  1. Testing, Requirements, and Metrics

    NASA Technical Reports Server (NTRS)

    Rosenberg, Linda; Hyatt, Larry; Hammer, Theodore F.; Huffman, Lenore; Wilson, William

    1998-01-01

    The criticality of correct, complete, testable requirements is a fundamental tenet of software engineering. Also critical is complete requirements based testing of the final product. Modern tools for managing requirements allow new metrics to be used in support of both of these critical processes. Using these tools, potential problems with the quality of the requirements and the test plan can be identified early in the life cycle. Some of these quality factors include: ambiguous or incomplete requirements, poorly designed requirements databases, excessive or insufficient test cases, and incomplete linkage of tests to requirements. This paper discusses how metrics can be used to evaluate the quality of the requirements and test to avoid problems later. Requirements management and requirements based testing have always been critical in the implementation of high quality software systems. Recently, automated tools have become available to support requirements management. At NASA's Goddard Space Flight Center (GSFC), automated requirements management tools are being used on several large projects. The use of these tools opens the door to innovative uses of metrics in characterizing test plan quality and assessing overall testing risks. In support of these projects, the Software Assurance Technology Center (SATC) is working to develop and apply a metrics program that utilizes the information now available through the application of requirements management tools. Metrics based on this information provides real-time insight into the testing of requirements and these metrics assist the Project Quality Office in its testing oversight role. This paper discusses three facets of the SATC's efforts to evaluate the quality of the requirements and test plan early in the life cycle, thus preventing costly errors and time delays later.

  2. Empirical Evaluation of Hunk Metrics as Bug Predictors

    NASA Astrophysics Data System (ADS)

    Ferzund, Javed; Ahsan, Syed Nadeem; Wotawa, Franz

    Reducing the number of bugs is a crucial issue during software development and maintenance. Software process and product metrics are good indicators of software complexity. These metrics have been used to build bug predictor models to help developers maintain the quality of software. In this paper we empirically evaluate the use of hunk metrics as predictor of bugs. We present a technique for bug prediction that works at smallest units of code change called hunks. We build bug prediction models using random forests, which is an efficient machine learning classifier. Hunk metrics are used to train the classifier and each hunk metric is evaluated for its bug prediction capabilities. Our classifier can classify individual hunks as buggy or bug-free with 86 % accuracy, 83 % buggy hunk precision and 77% buggy hunk recall. We find that history based and change level hunk metrics are better predictors of bugs than code level hunk metrics.

  3. The software product assurance metrics study: JPL's software systems quality and productivity

    NASA Technical Reports Server (NTRS)

    Bush, Marilyn W.

    1989-01-01

    The findings are reported of the Jet Propulsion Laboratory (JPL)/Software Product Assurance (SPA) Metrics Study, conducted as part of a larger JPL effort to improve software quality and productivity. Until recently, no comprehensive data had been assembled on how JPL manages and develops software-intensive systems. The first objective was to collect data on software development from as many projects and for as many years as possible. Results from five projects are discussed. These results reflect 15 years of JPL software development, representing over 100 data points (systems and subsystems), over a third of a billion dollars, over four million lines of code and 28,000 person months. Analysis of this data provides a benchmark for gauging the effectiveness of past, present and future software development work. In addition, the study is meant to encourage projects to record existing metrics data and to gather future data. The SPA long term goal is to integrate the collection of historical data and ongoing project data with future project estimations.

  4. Specification-based software sizing: An empirical investigation of function metrics

    NASA Technical Reports Server (NTRS)

    Jeffery, Ross; Stathis, John

    1993-01-01

    For some time the software industry has espoused the need for improved specification-based software size metrics. This paper reports on a study of nineteen recently developed systems in a variety of application domains. The systems were developed by a single software services corporation using a variety of languages. The study investigated several metric characteristics. It shows that: earlier research into inter-item correlation within the overall function count is partially supported; a priori function counts, in themself, do not explain the majority of the effort variation in software development in the organization studied; documentation quality is critical to accurate function identification; and rater error is substantial in manual function counting. The implication of these findings for organizations using function based metrics are explored.

  5. The validation by measurement theory of proposed object-oriented software metrics

    NASA Technical Reports Server (NTRS)

    Neal, Ralph D.

    1994-01-01

    Moving software development into the engineering arena requires controllability, and to control a process, it must be measurable. Measuring the process does no good if the product is not also measured, i.e., being the best at producing an inferior product does not define a quality process. Also, not every number extracted from software development is a valid measurement. A valid measurement only results when we are able to verify that the number is representative of the attribute that we wish to measure. Many proposed software metrics are used by practitioners without these metrics ever having been validated, leading to costly but often useless calculations. Several researchers have bemoaned the lack of scientific precision in much of the published software measurement work and have called for validation of software metrics by measurement theory. This dissertation applies measurement theory to validate fifty proposed object-oriented software metrics (Li and Henry, 1993; Chidamber and Kemerrer, 1994; Lorenz and Kidd, 1994).

  6. Calculation and use of an environment's characteristic software metric set

    NASA Technical Reports Server (NTRS)

    Basili, Victor R.; Selby, Richard W., Jr.

    1985-01-01

    Since both cost/quality and production environments differ, this study presents an approach for customizing a characteristic set of software metrics to an environment. The approach is applied in the Software Engineering Laboratory (SEL), a NASA Goddard production environment, to 49 candidate process and product metrics of 652 modules from six (51,000 to 112,000 lines) projects. For this particular environment, the method yielded the characteristic metric set (source lines, fault correction effort per executable statement, design effort, code effort, number of I/O parameters, number of versions). The uses examined for a characteristic metric set include forecasting the effort for development, modification, and fault correction of modules based on historical data.

  7. Software Quality Metrics Enhancements. Volume 1

    DTIC Science & Technology

    1980-04-01

    the mathematical relationships which relate metrics to ratings of the various quality factors) for factors which were not validated previously were...function, provides a mathematical relationship between the metrics and the quality factors. (3) Validation of these normalization functions was performed by...samples, further research is needed before a high degree of confidence can be placed on the mathematical relationships established to date l (3.3.3) 6

  8. Software quality for 1997 - what works and what doesn`t?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, C.

    1997-11-01

    This presentation provides a view of software quality for 1997 - what works and what doesn`t. For many years, software quality assurance lagged behind hardware quality assurance in terms of methods, metrics, and successful results. New approaches such as Quality Function Development (WFD) the ISO 9000-9004 standards, the SEI maturity levels, and Total Quality Management (TQM) are starting to attract wide attention, and in some cases to bring software quality levels up to a parity with manufacturing quality levels.

  9. Gaining Control and Predictability of Software-Intensive Systems Development and Sustainment

    DTIC Science & Technology

    2015-02-04

    implementation of the baselines, audits , and technical reviews within an overarching systems engineering process (SEP; Defense Acquisition University...warfighters’ needs. This management and metrics effort supplements and supports the system’s technical development through the baselines, audits and...other areas that could be researched and added into the nine-tier model. Areas including software metrics, quality assurance , software-oriented

  10. Using software metrics and software reliability models to attain acceptable quality software for flight and ground support software for avionic systems

    NASA Technical Reports Server (NTRS)

    Lawrence, Stella

    1992-01-01

    This paper is concerned with methods of measuring and developing quality software. Reliable flight and ground support software is a highly important factor in the successful operation of the space shuttle program. Reliability is probably the most important of the characteristics inherent in the concept of 'software quality'. It is the probability of failure free operation of a computer program for a specified time and environment.

  11. SIMPATIQCO: a server-based software suite which facilitates monitoring the time course of LC-MS performance metrics on Orbitrap instruments.

    PubMed

    Pichler, Peter; Mazanek, Michael; Dusberger, Frederico; Weilnböck, Lisa; Huber, Christian G; Stingl, Christoph; Luider, Theo M; Straube, Werner L; Köcher, Thomas; Mechtler, Karl

    2012-11-02

    While the performance of liquid chromatography (LC) and mass spectrometry (MS) instrumentation continues to increase, applications such as analyses of complete or near-complete proteomes and quantitative studies require constant and optimal system performance. For this reason, research laboratories and core facilities alike are recommended to implement quality control (QC) measures as part of their routine workflows. Many laboratories perform sporadic quality control checks. However, successive and systematic longitudinal monitoring of system performance would be facilitated by dedicated automatic or semiautomatic software solutions that aid an effortless analysis and display of QC metrics over time. We present the software package SIMPATIQCO (SIMPle AuTomatIc Quality COntrol) designed for evaluation of data from LTQ Orbitrap, Q-Exactive, LTQ FT, and LTQ instruments. A centralized SIMPATIQCO server can process QC data from multiple instruments. The software calculates QC metrics supervising every step of data acquisition from LC and electrospray to MS. For each QC metric the software learns the range indicating adequate system performance from the uploaded data using robust statistics. Results are stored in a database and can be displayed in a comfortable manner from any computer in the laboratory via a web browser. QC data can be monitored for individual LC runs as well as plotted over time. SIMPATIQCO thus assists the longitudinal monitoring of important QC metrics such as peptide elution times, peak widths, intensities, total ion current (TIC) as well as sensitivity, and overall LC-MS system performance; in this way the software also helps identify potential problems. The SIMPATIQCO software package is available free of charge.

  12. SIMPATIQCO: A Server-Based Software Suite Which Facilitates Monitoring the Time Course of LC–MS Performance Metrics on Orbitrap Instruments

    PubMed Central

    2012-01-01

    While the performance of liquid chromatography (LC) and mass spectrometry (MS) instrumentation continues to increase, applications such as analyses of complete or near-complete proteomes and quantitative studies require constant and optimal system performance. For this reason, research laboratories and core facilities alike are recommended to implement quality control (QC) measures as part of their routine workflows. Many laboratories perform sporadic quality control checks. However, successive and systematic longitudinal monitoring of system performance would be facilitated by dedicated automatic or semiautomatic software solutions that aid an effortless analysis and display of QC metrics over time. We present the software package SIMPATIQCO (SIMPle AuTomatIc Quality COntrol) designed for evaluation of data from LTQ Orbitrap, Q-Exactive, LTQ FT, and LTQ instruments. A centralized SIMPATIQCO server can process QC data from multiple instruments. The software calculates QC metrics supervising every step of data acquisition from LC and electrospray to MS. For each QC metric the software learns the range indicating adequate system performance from the uploaded data using robust statistics. Results are stored in a database and can be displayed in a comfortable manner from any computer in the laboratory via a web browser. QC data can be monitored for individual LC runs as well as plotted over time. SIMPATIQCO thus assists the longitudinal monitoring of important QC metrics such as peptide elution times, peak widths, intensities, total ion current (TIC) as well as sensitivity, and overall LC–MS system performance; in this way the software also helps identify potential problems. The SIMPATIQCO software package is available free of charge. PMID:23088386

  13. Configuration management and software measurement in the Ground Systems Development Environment (GSDE)

    NASA Technical Reports Server (NTRS)

    Church, Victor E.; Long, D.; Hartenstein, Ray; Perez-Davila, Alfredo

    1992-01-01

    A set of functional requirements for software configuration management (CM) and metrics reporting for Space Station Freedom ground systems software are described. This report is one of a series from a study of the interfaces among the Ground Systems Development Environment (GSDE), the development systems for the Space Station Training Facility (SSTF) and the Space Station Control Center (SSCC), and the target systems for SSCC and SSTF. The focus is on the CM of the software following delivery to NASA and on the software metrics that relate to the quality and maintainability of the delivered software. The CM and metrics requirements address specific problems that occur in large-scale software development. Mechanisms to assist in the continuing improvement of mission operations software development are described.

  14. Initial Ada components evaluation

    NASA Technical Reports Server (NTRS)

    Moebes, Travis

    1989-01-01

    The SAIC has the responsibility for independent test and validation of the SSE. They have been using a mathematical functions library package implemented in Ada to test the SSE IV and V process. The library package consists of elementary mathematical functions and is both machine and accuracy independent. The SSE Ada components evaluation includes code complexity metrics based on Halstead's software science metrics and McCabe's measure of cyclomatic complexity. Halstead's metrics are based on the number of operators and operands on a logical unit of code and are compiled from the number of distinct operators, distinct operands, and total number of occurrences of operators and operands. These metrics give an indication of the physical size of a program in terms of operators and operands and are used diagnostically to point to potential problems. McCabe's Cyclomatic Complexity Metrics (CCM) are compiled from flow charts transformed to equivalent directed graphs. The CCM is a measure of the total number of linearly independent paths through the code's control structure. These metrics were computed for the Ada mathematical functions library using Software Automated Verification and Validation (SAVVAS), the SSE IV and V tool. A table with selected results was shown, indicating that most of these routines are of good quality. Thresholds for the Halstead measures indicate poor quality if the length metric exceeds 260 or difficulty is greater than 190. The McCabe CCM indicated a high quality of software products.

  15. Improving Software Quality and Management Through Use of Service Level Agreements

    DTIC Science & Technology

    2005-03-01

    many who believe that the quality of the development process is the best predictor of software product quality. ( Fenton ) Repeatable software processes...reduced errors per KLOC for small projects ( Fenton ), and the quality management metric (QMM) (Machniak, Osmundson). There are also numerous IEEE 14...attention to cosmetic user interface issues and any problems that may arise with the prototype. (Sawyer) The validation process is also another check

  16. Metric analysis and data validation across FORTRAN projects

    NASA Technical Reports Server (NTRS)

    Basili, Victor R.; Selby, Richard W., Jr.; Phillips, Tsai-Yun

    1983-01-01

    The desire to predict the effort in developing or explaining the quality of software has led to the proposal of several metrics. As a step toward validating these metrics, the Software Engineering Laboratory (SEL) has analyzed the software science metrics, cyclomatic complexity, and various standard program measures for their relation to effort (including design through acceptance testing), development errors (both discrete and weighted according to the amount of time to locate and fix), and one another. The data investigated are collected from a project FORTRAN environment and examined across several projects at once, within individual projects and by reporting accuracy checks demonstrating the need to validate a database. When the data comes from individual programmers or certain validated projects, the metrics' correlations with actual effort seem to be strongest. For modules developed entirely by individual programmers, the validity ratios induce a statistically significant ordering of several of the metrics' correlations. When comparing the strongest correlations, neither software science's E metric cyclomatic complexity not source lines of code appears to relate convincingly better with effort than the others.

  17. Reuse Metrics for Object Oriented Software

    NASA Technical Reports Server (NTRS)

    Bieman, James M.

    1998-01-01

    One way to increase the quality of software products and the productivity of software development is to reuse existing software components when building new software systems. In order to monitor improvements in reuse, the level of reuse must be measured. In this NASA supported project we (1) derived a suite of metrics which quantify reuse attributes for object oriented, object based, and procedural software, (2) designed prototype tools to take these measurements in Ada, C++, Java, and C software, (3) evaluated the reuse in available software, (4) analyzed the relationship between coupling, cohesion, inheritance, and reuse, (5) collected object oriented software systems for our empirical analyses, and (6) developed quantitative criteria and methods for restructuring software to improve reusability.

  18. Software quality in 1997

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, C.

    1997-11-01

    For many years, software quality assurance lagged behind hardware quality assurance in terms of methods, metrics, and successful results. New approaches such as Quality Function Deployment (QFD) the ISO 9000-9004 standards, the SEI maturity levels, and Total Quality Management (TQM) are starting to attract wide attention, and in some cases to bring software quality levels up to a parity with manufacturing quality levels. Since software is on the critical path for many engineered products, and for internal business systems as well, the new approaches are starting to affect global competition and attract widespread international interest. It can be hypothesized thatmore » success in mastering software quality will be a key strategy for dominating global software markets in the 21st century.« less

  19. Quality assurance software inspections at NASA Ames: Metrics for feedback and modification

    NASA Technical Reports Server (NTRS)

    Wenneson, G.

    1985-01-01

    Software inspections are a set of formal technical review procedures held at selected key points during software development in order to find defects in software documents--is described in terms of history, participants, tools, procedures, statistics, and database analysis.

  20. The Role and Quality of Software Safety in the NASA Constellation Program

    NASA Technical Reports Server (NTRS)

    Layman, Lucas; Basili, Victor R.; Zelkowitz, Marvin V.

    2010-01-01

    In this study, we examine software safety risk in the early design phase of the NASA Constellation spaceflight program. Obtaining an accurate, program-wide picture of software safety risk is difficult across multiple, independently-developing systems. We leverage one source of safety information, hazard analysis, to provide NASA quality assurance managers with information regarding the ongoing state of software safety across the program. The goal of this research is two-fold: 1) to quantify the relative importance of software with respect to system safety; and 2) to quantify the level of risk presented by software in the hazard analysis. We examined 154 hazard reports created during the preliminary design phase of three major flight hardware systems within the Constellation program. To quantify the importance of software, we collected metrics based on the number of software-related causes and controls of hazardous conditions. To quantify the level of risk presented by software, we created a metric scheme to measure the specificity of these software causes. We found that from 49-70% of hazardous conditions in the three systems could be caused by software or software was involved in the prevention of the hazardous condition. We also found that 12-17% of the 2013 hazard causes involved software, and that 23-29% of all causes had a software control. Furthermore, 10-12% of all controls were software-based. There is potential for inaccuracy in these counts, however, as software causes are not consistently scoped, and the presence of software in a cause or control is not always clear. The application of our software specificity metrics also identified risks in the hazard reporting process. In particular, we found a number of traceability risks in the hazard reports may impede verification of software and system safety.

  1. Quality measures and assurance for AI (Artificial Intelligence) software

    NASA Technical Reports Server (NTRS)

    Rushby, John

    1988-01-01

    This report is concerned with the application of software quality and evaluation measures to AI software and, more broadly, with the question of quality assurance for AI software. Considered are not only the metrics that attempt to measure some aspect of software quality, but also the methodologies and techniques (such as systematic testing) that attempt to improve some dimension of quality, without necessarily quantifying the extent of the improvement. The report is divided into three parts Part 1 reviews existing software quality measures, i.e., those that have been developed for, and applied to, conventional software. Part 2 considers the characteristics of AI software, the applicability and potential utility of measures and techniques identified in the first part, and reviews those few methods developed specifically for AI software. Part 3 presents an assessment and recommendations for the further exploration of this important area.

  2. A Quantitative Analysis of Open Source Software's Acceptability as Production-Quality Code

    ERIC Educational Resources Information Center

    Fischer, Michael

    2011-01-01

    The difficulty in writing defect-free software has been long acknowledged both by academia and industry. A constant battle occurs as developers seek to craft software that works within aggressive business schedules and deadlines. Many tools and techniques are used in attempt to manage these software projects. Software metrics are a tool that has…

  3. Towards the XML schema measurement based on mapping between XML and OO domain

    NASA Astrophysics Data System (ADS)

    Rakić, Gordana; Budimac, Zoran; Heričko, Marjan; Pušnik, Maja

    2017-07-01

    Measuring quality of IT solutions is a priority in software engineering. Although numerous metrics for measuring object-oriented code already exist, measuring quality of UML models or XML Schemas is still developing. One of the research questions in the overall research leaded by ideas described in this paper is whether we can apply already defined object-oriented design metrics on XML schemas based on predefined mappings. In this paper, basic ideas for mentioned mapping are presented. This mapping is prerequisite for setting the future approach to XML schema quality measuring with object-oriented metrics.

  4. A Predictive Approach to Eliminating Errors in Software Code

    NASA Technical Reports Server (NTRS)

    2006-01-01

    NASA s Metrics Data Program Data Repository is a database that stores problem, product, and metrics data. The primary goal of this data repository is to provide project data to the software community. In doing so, the Metrics Data Program collects artifacts from a large NASA dataset, generates metrics on the artifacts, and then generates reports that are made available to the public at no cost. The data that are made available to general users have been sanitized and authorized for publication through the Metrics Data Program Web site by officials representing the projects from which the data originated. The data repository is operated by NASA s Independent Verification and Validation (IV&V) Facility, which is located in Fairmont, West Virginia, a high-tech hub for emerging innovation in the Mountain State. The IV&V Facility was founded in 1993, under the NASA Office of Safety and Mission Assurance, as a direct result of recommendations made by the National Research Council and the Report of the Presidential Commission on the Space Shuttle Challenger Accident. Today, under the direction of Goddard Space Flight Center, the IV&V Facility continues its mission to provide the highest achievable levels of safety and cost-effectiveness for mission-critical software. By extending its data to public users, the facility has helped improve the safety, reliability, and quality of complex software systems throughout private industry and other government agencies. Integrated Software Metrics, Inc., is one of the organizations that has benefited from studying the metrics data. As a result, the company has evolved into a leading developer of innovative software-error prediction tools that help organizations deliver better software, on time and on budget.

  5. The development and application of composite complexity models and a relative complexity metric in a software maintenance environment

    NASA Technical Reports Server (NTRS)

    Hops, J. M.; Sherif, J. S.

    1994-01-01

    A great deal of effort is now being devoted to the study, analysis, prediction, and minimization of software maintenance expected cost, long before software is delivered to users or customers. It has been estimated that, on the average, the effort spent on software maintenance is as costly as the effort spent on all other software costs. Software design methods should be the starting point to aid in alleviating the problems of software maintenance complexity and high costs. Two aspects of maintenance deserve attention: (1) protocols for locating and rectifying defects, and for ensuring that noe new defects are introduced in the development phase of the software process; and (2) protocols for modification, enhancement, and upgrading. This article focuses primarily on the second aspect, the development of protocols to help increase the quality and reduce the costs associated with modifications, enhancements, and upgrades of existing software. This study developed parsimonious models and a relative complexity metric for complexity measurement of software that were used to rank the modules in the system relative to one another. Some success was achieved in using the models and the relative metric to identify maintenance-prone modules.

  6. Design Aids for Real-Time Systems (DARTS)

    NASA Technical Reports Server (NTRS)

    Szulewski, P. A.

    1982-01-01

    Design-Aids for Real-Time Systems (DARTS) is a tool that assists in defining embedded computer systems through tree structured graphics, military standard documentation support, and various analyses including automated Software Science parameter counting and metrics calculation. These analyses provide both static and dynamic design quality feedback which can potentially aid in producing efficient, high quality software systems.

  7. Software Quality Metrics: A Software Management Monitoring Method for Air Force Logistics Command in Its Software Quality Assurance Program for the Quantitative Assessment of the System Development Life Cycle under Configuration Management.

    DTIC Science & Technology

    1982-03-01

    pilot systems. Magnitude of the mutant error is classified as: o Program does not compute. o Program computes but does not run test data. o Program...14 Test and Integration ... ............ .. 105 15 The Mapping of SQM to the SDLC ........ ... 108 16 ADS Development .... .............. . 224 17...and funds. While the test phase concludes the normal development cycle, one should realize that with software the development continues in the

  8. METRICS DEVELOPMENT FOR THE QUALIS OF SOFTWARE TECHNICAL PRODUCTION.

    PubMed

    Scarpi, Marinho Jorge

    2015-01-01

    To recommend metrics to qualify software production and to propose guidelines for the CAPES quadrennial evaluation of the Post-Graduation Programs of Medicine III about this issue. Identification of the development process quality features, of the product attributes and of the software use, determined by Brazilian Association of Technical Standards (ABNT), International Organization Standardization (ISO) and International Electrotechnical (IEC), important in the perspective of the CAPES Medicine III Area correlate users, basing the creation proposal of metrics aiming to be used on four-year evaluation of Medicine III. The in use software quality perception by the user results from the provided effectiveness, productivity, security and satisfaction that originate from its characteristics of functionality, reliability, usability, efficiency, maintainability and portability (in use metrics quality). This perception depends on the specific use scenario. The software metrics should be included in the intellectual production of the program, considering the system behavior measurements results obtained by users' performance evaluation through out the favorable responses punctuation sum for the six in use metrics quality (27 sub-items, 0 to 2 points each) and for quality perception proof (four items, 0 to 10 points each). It will be considered as very good (VG) 85 to 94 points; good (G) 75 to 84 points; regular (R) 65 to 74 points; weak (W) 55 to 64 points; poor (P) <55 points. Recomendar métrica para qualificar a produção de software propondo diretrizes para a avaliação dos Programas de Pós-Graduação da Medicina III. Identificação das características de qualidade para o processo de desenvolvimento, para os atributos do produto e para o uso de software, determinadas pela Associação Brasileira de Normas Técnicas (ABNT), International Organization Standardization (ISO) e International Electrotechnical (IEC), importantes na perspectiva dos usuários correlatos da Área Medicina III da CAPES, embasando a criação de proposta para métrica do tema, com vistas à avaliação quadrienal dos cursos de pós-graduação. A percepção de qualidade em uso do software pelo usuário resulta da efetividade, produtividade, segurança e satisfação proporcionada, que têm origem nas suas características de funcionalidade, confiabilidade, usabilidade, eficiência, manutenibilidade e portabilidade (métricas de qualidade em uso). Tal percepção depende do cenário de uso específico. A métrica de software deve ser incluída na produção intelectual do Documento de Área do programa, ponderando os resultados nas medidas de comportamento do sistema em avaliação de desempenho por usuários, considerando a somatória da pontuação favorável para as seis métricas de qualidade em uso (27 sub-itens, de 0 a 2 pontos cada) e a comprovação da percepção de qualidade (quatro itens, de 0 a 10 pontos cada). Será considerado muito bom (MB) de 85 a 94 pontos; bom (B) de 75 a 84 pontos; Regular (R) de 65 a 74 pontos; fraco (F) de 55 a 64 pontos; deficiente (D) < 55.

  9. SU-E-T-776: Use of Quality Metrics for a New Hypo-Fractionated Pre-Surgical Mesothelioma Protocol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richardson, S; Mehta, V

    Purpose: The “SMART” (Surgery for Mesothelioma After Radiation Therapy) approach involves hypo-fractionated radiotherapy of the lung pleura to 25Gy over 5 days followed by surgical resection within 7. Early clinical results suggest that this approach is very promising, but also logistically challenging due to the multidisciplinary involvement. Due to the compressed schedule, high dose, and shortened planning time, the delivery of the planned doses were monitored for safety with quality metric software. Methods: Hypo-fractionated IMRT treatment plans were developed for all patients and exported to Quality Reports™ software. Plan quality metrics or PQMs™ were created to calculate an objective scoringmore » function for each plan. This allows for an objective assessment of the quality of the plan and a benchmark for plan improvement for subsequent patients. The priorities of various components were incorporated based on similar hypo-fractionated protocols such as lung SBRT treatments. Results: Five patients have been treated at our institution using this approach. The plans were developed, QA performed, and ready within 5 days of simulation. Plan Quality metrics utilized in scoring included doses to OAR and target coverage. All patients tolerated treatment well and proceeded to surgery as scheduled. Reported toxicity included grade 1 nausea (n=1), grade 1 esophagitis (n=1), grade 2 fatigue (n=3). One patient had recurrent fluid accumulation following surgery. No patients experienced any pulmonary toxicity prior to surgery. Conclusion: An accelerated course of pre-operative high dose radiation for mesothelioma is an innovative and promising new protocol. Without historical data, one must proceed cautiously and monitor the data carefully. The development of quality metrics and scoring functions for these treatments allows us to benchmark our plans and monitor improvement. If subsequent toxicities occur, these will be easy to investigate and incorporate into the metrics. This will improve the safe delivery of large doses for these patients.« less

  10. StreamThermal: A software package for calculating thermal metrics from stream temperature data

    USGS Publications Warehouse

    Tsang, Yin-Phan; Infante, Dana M.; Stewart, Jana S.; Wang, Lizhu; Tingly, Ralph; Thornbrugh, Darren; Cooper, Arthur; Wesley, Daniel

    2016-01-01

    Improving quality and better availability of continuous stream temperature data allows natural resource managers, particularly in fisheries, to understand associations between different characteristics of stream thermal regimes and stream fishes. However, there is no convenient tool to efficiently characterize multiple metrics reflecting stream thermal regimes with the increasing amount of data. This article describes a software program packaged as a library in R to facilitate this process. With this freely-available package, users will be able to quickly summarize metrics that describe five categories of stream thermal regimes: magnitude, variability, frequency, timing, and rate of change. The installation and usage instruction of this package, the definition of calculated thermal metrics, as well as the output format from the package are described, along with an application showing the utility for multiple metrics. We believe this package can be widely utilized by interested stakeholders and greatly assist more studies in fisheries.

  11. Proteomics Quality Control: Quality Control Software for MaxQuant Results.

    PubMed

    Bielow, Chris; Mastrobuoni, Guido; Kempa, Stefan

    2016-03-04

    Mass spectrometry-based proteomics coupled to liquid chromatography has matured into an automatized, high-throughput technology, producing data on the scale of multiple gigabytes per instrument per day. Consequently, an automated quality control (QC) and quality analysis (QA) capable of detecting measurement bias, verifying consistency, and avoiding propagation of error is paramount for instrument operators and scientists in charge of downstream analysis. We have developed an R-based QC pipeline called Proteomics Quality Control (PTXQC) for bottom-up LC-MS data generated by the MaxQuant software pipeline. PTXQC creates a QC report containing a comprehensive and powerful set of QC metrics, augmented with automated scoring functions. The automated scores are collated to create an overview heatmap at the beginning of the report, giving valuable guidance also to nonspecialists. Our software supports a wide range of experimental designs, including stable isotope labeling by amino acids in cell culture (SILAC), tandem mass tags (TMT), and label-free data. Furthermore, we introduce new metrics to score MaxQuant's Match-between-runs (MBR) functionality by which peptide identifications can be transferred across Raw files based on accurate retention time and m/z. Last but not least, PTXQC is easy to install and use and represents the first QC software capable of processing MaxQuant result tables. PTXQC is freely available at https://github.com/cbielow/PTXQC .

  12. Software Metrics

    DTIC Science & Technology

    1988-12-01

    software development scene is often charac- c. SPQR Model-Jones terized by: * schedule and cost estimates that are gross-d. COPMO-Thebaut ly inaccurate, SEI...time c. SPQR Model-Jones (in seconds) is simply derived from E by dividing T. Capers Jones has developed a software cost by the Stroud number, S...estimation model called the Software Produc- T=E/S tivity, Quality, and Reliability ( SPQR ) model. The basic approach is similar to that of Boehm’s The value

  13. Agile Software Development in Defense Acquisition: A Mission Assurance Perspective

    DTIC Science & Technology

    2012-03-23

    based information retrieval system, we might say that this program works like a hive of bees , going out for pollen and bringing it back to the hive...developers ® Six Siqma is reqistered in the U. S. Patent and Trademark Office by Motorola ^_ 33 @ AEROSPACE Major Areas in a Typical Software...requirements - Capturing and evaluating quality metrics, identifying common problem areas **» Despite its positive impact on quality, pair programming

  14. Automatic extraction and visualization of object-oriented software design metrics

    NASA Astrophysics Data System (ADS)

    Lakshminarayana, Anuradha; Newman, Timothy S.; Li, Wei; Talburt, John

    2000-02-01

    Software visualization is a graphical representation of software characteristics and behavior. Certain modes of software visualization can be useful in isolating problems and identifying unanticipated behavior. In this paper we present a new approach to aid understanding of object- oriented software through 3D visualization of software metrics that can be extracted from the design phase of software development. The focus of the paper is a metric extraction method and a new collection of glyphs for multi- dimensional metric visualization. Our approach utilize the extensibility interface of a popular CASE tool to access and automatically extract the metrics from Unified Modeling Language class diagrams. Following the extraction of the design metrics, 3D visualization of these metrics are generated for each class in the design, utilizing intuitively meaningful 3D glyphs that are representative of the ensemble of metrics. Extraction and visualization of design metrics can aid software developers in the early study and understanding of design complexity.

  15. An Experimental Investigation of Computer Program Development Approaches and Computer Programming Metrics.

    DTIC Science & Technology

    1979-12-01

    team progranming in reducing software dleveloup- ment costs relative to ad hoc approaches and improving software product quality relative to...are interpreted as demonstrating the advantages of disciplined team programming in reducing software development costs relative to ad hoc approaches...is due oartialty to the cost and imoracticality of a valiI experimental setup within a oroauct ion environment. Thus the question remains, are

  16. Survivability as a Tool for Evaluating Open Source Software

    DTIC Science & Technology

    2015-06-01

    the thesis limited the program development, so it is only able to process project issues (bugs or feature requests), which is an important metric for...Ideally, these insights may provide an analytic framework to generate guidance for decision makers that may support the inclusion of OSS to more...refine their efforts to build quality software and to strengthen their software development communities. 1.4 Research Questions This thesis addresses

  17. ChiLin: a comprehensive ChIP-seq and DNase-seq quality control and analysis pipeline.

    PubMed

    Qin, Qian; Mei, Shenglin; Wu, Qiu; Sun, Hanfei; Li, Lewyn; Taing, Len; Chen, Sujun; Li, Fugen; Liu, Tao; Zang, Chongzhi; Xu, Han; Chen, Yiwen; Meyer, Clifford A; Zhang, Yong; Brown, Myles; Long, Henry W; Liu, X Shirley

    2016-10-03

    Transcription factor binding, histone modification, and chromatin accessibility studies are important approaches to understanding the biology of gene regulation. ChIP-seq and DNase-seq have become the standard techniques for studying protein-DNA interactions and chromatin accessibility respectively, and comprehensive quality control (QC) and analysis tools are critical to extracting the most value from these assay types. Although many analysis and QC tools have been reported, few combine ChIP-seq and DNase-seq data analysis and quality control in a unified framework with a comprehensive and unbiased reference of data quality metrics. ChiLin is a computational pipeline that automates the quality control and data analyses of ChIP-seq and DNase-seq data. It is developed using a flexible and modular software framework that can be easily extended and modified. ChiLin is ideal for batch processing of many datasets and is well suited for large collaborative projects involving ChIP-seq and DNase-seq from different designs. ChiLin generates comprehensive quality control reports that include comparisons with historical data derived from over 23,677 public ChIP-seq and DNase-seq samples (11,265 datasets) from eight literature-based classified categories. To the best of our knowledge, this atlas represents the most comprehensive ChIP-seq and DNase-seq related quality metric resource currently available. These historical metrics provide useful heuristic quality references for experiment across all commonly used assay types. Using representative datasets, we demonstrate the versatility of the pipeline by applying it to different assay types of ChIP-seq data. The pipeline software is available open source at https://github.com/cfce/chilin . ChiLin is a scalable and powerful tool to process large batches of ChIP-seq and DNase-seq datasets. The analysis output and quality metrics have been structured into user-friendly directories and reports. We have successfully compiled 23,677 profiles into a comprehensive quality atlas with fine classification for users.

  18. RNA-SeQC: RNA-seq metrics for quality control and process optimization.

    PubMed

    DeLuca, David S; Levin, Joshua Z; Sivachenko, Andrey; Fennell, Timothy; Nazaire, Marc-Danie; Williams, Chris; Reich, Michael; Winckler, Wendy; Getz, Gad

    2012-06-01

    RNA-seq, the application of next-generation sequencing to RNA, provides transcriptome-wide characterization of cellular activity. Assessment of sequencing performance and library quality is critical to the interpretation of RNA-seq data, yet few tools exist to address this issue. We introduce RNA-SeQC, a program which provides key measures of data quality. These metrics include yield, alignment and duplication rates; GC bias, rRNA content, regions of alignment (exon, intron and intragenic), continuity of coverage, 3'/5' bias and count of detectable transcripts, among others. The software provides multi-sample evaluation of library construction protocols, input materials and other experimental parameters. The modularity of the software enables pipeline integration and the routine monitoring of key measures of data quality such as the number of alignable reads, duplication rates and rRNA contamination. RNA-SeQC allows investigators to make informed decisions about sample inclusion in downstream analysis. In summary, RNA-SeQC provides quality control measures critical to experiment design, process optimization and downstream computational analysis. See www.genepattern.org to run online, or www.broadinstitute.org/rna-seqc/ for a command line tool.

  19. A Validation of Object-Oriented Design Metrics as Quality Indicators

    NASA Technical Reports Server (NTRS)

    Basili, Victor R.; Briand, Lionel C.; Melo, Walcelio

    1997-01-01

    This paper presents the results of a study in which we empirically investigated the suits of object-oriented (00) design metrics introduced in another work. More specifically, our goal is to assess these metrics as predictors of fault-prone classes and, therefore, determine whether they can be used as early quality indicators. This study is complementary to the work described where the same suite of metrics had been used to assess frequencies of maintenance changes to classes. To perform our validation accurately, we collected data on the development of eight medium-sized information management systems based on identical requirements. All eight projects were developed using a sequential life cycle model, a well-known 00 analysis/design method and the C++ programming language. Based on empirical and quantitative analysis, the advantages and drawbacks of these 00 metrics are discussed. Several of Chidamber and Kamerer's 00 metrics appear to be useful to predict class fault-proneness during the early phases of the life-cycle. Also, on our data set, they are better predictors than 'traditional' code metrics, which can only be collected at a later phase of the software development processes.

  20. A neural net-based approach to software metrics

    NASA Technical Reports Server (NTRS)

    Boetticher, G.; Srinivas, Kankanahalli; Eichmann, David A.

    1992-01-01

    Software metrics provide an effective method for characterizing software. Metrics have traditionally been composed through the definition of an equation. This approach is limited by the fact that all the interrelationships among all the parameters be fully understood. This paper explores an alternative, neural network approach to modeling metrics. Experiments performed on two widely accepted metrics, McCabe and Halstead, indicate that the approach is sound, thus serving as the groundwork for further exploration into the analysis and design of software metrics.

  1. The role of metrics and measurements in a software intensive total quality management environment

    NASA Technical Reports Server (NTRS)

    Daniels, Charles B.

    1992-01-01

    Paramax Space Systems began its mission as a member of the Rockwell Space Operations Company (RSOC) team which was the successful bidder on a massive operations consolidation contract for the Mission Operations Directorate (MOD) at JSC. The contract awarded to the team was the Space Transportation System Operations Contract (STSOC). Our initial challenge was to accept responsibility for a very large, highly complex and fragmented collection of software from eleven different contractors and transform it into a coherent, operational baseline. Concurrently, we had to integrate a diverse group of people from eleven different companies into a single, cohesive team. Paramax executives recognized the absolute necessity to develop a business culture based on the concept of employee involvement to execute and improve the complex process of our new environment. Our executives clearly understood that management needed to set the example and lead the way to quality improvement. The total quality management policy and the metrics used in this endeavor are presented.

  2. FQC Dashboard: integrates FastQC results into a web-based, interactive, and extensible FASTQ quality control tool

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, Joseph; Pirrung, Meg; McCue, Lee Ann

    FQC is software that facilitates large-scale quality control of FASTQ files by carrying out a QC protocol, parsing results, and aggregating quality metrics within and across experiments into an interactive dashboard. The dashboard utilizes human-readable configuration files to manipulate the pages and tabs, and is extensible with CSV data.

  3. WE-G-204-09: Medical Physics 2.0 in Practice: Automated QC Assessment of Clinical Chest Images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Willis, C; Willis, C; Nishino, T

    2015-06-15

    Purpose: To determine whether a proposed suite of objective image quality metrics for digital chest radiographs is useful for monitoring image quality in our clinical operation. Methods: Seventeen gridless AP Chest radiographs from a GE Optima portable digital radiography (DR) unit (Group 1), seventeen (routine) PA Chest radiographs from a GE Discovery DR unit (Group 2), and sixteen gridless (non-routine) PA Chest radiographs from the same Discovery DR unit (Group 3) were chosen for analysis. Groups were selected to represent “sub-standard” (Group 1), “standard-of-care” (Group 2), and images with a gross technical error (Group 3). Group 1 images were acquiredmore » with lower kVp (90 vs. 125), shorter source-to-image distance (127cm vs 183cm) and were expected to have lower quality than images in Group 2. Group 3 was expected to have degraded contrast versus Group 2.This evaluation was approved by the institutional Quality Improvement Assurance Board (QIAB). Images were anonymized and securely transferred to the Duke University Clinical Imaging Physics Group for analysis using software previously described{sup 1} and validated{sup 2}. Image quality for individual images was reported in terms of lung grey level(Lgl); lung noise(Ln); rib-lung contrast(RLc); rib sharpness(Rs); mediastinum detail(Md), noise(Mn), and alignment(Ma); subdiaphragm-lung contrast(SLc); and subdiaphragm area(Sa). Metrics were compared across groups. Results: Metrics agreed with published Quality Consistency Ranges with three exceptions: higher Lgl, lower RLc, and SDc. Higher bit depth (16 vs 12) accounted for higher Lgl values in our images. Values were most internally consistent for Group 2. The most sensitive metric for distinguishing between groups was Mn followed closely by Ln. The least sensitive metrics were Md and RLc. Conclusion: The software appears promising for objectively and automatically identifying substandard images in our operation. The results can be used to establish local quality consistency ranges and action limits per facility preferences.« less

  4. Requirements UML Tool (RUT) Expanded for Extreme Programming (CI02)

    NASA Technical Reports Server (NTRS)

    McCoy, James R.

    2003-01-01

    A procedure for capturing and managing system requirements that incorporates XP user stories. Because costs associated with identifying problems in requirements increase dramatically over the lifecycle of a project, a method for identifying sources of software risks in user stories is urgently needed. This initiative aims to determine a set of guide-lines for user stories that will result in high-quality requirement. To further this initiative, a tool is needed to analyze user stories that can assess the quality of individual user stories, detect sources cf software risk's, produce software metrics, and identify areas in user stories that can be improved.

  5. Understanding software faults and their role in software reliability modeling

    NASA Technical Reports Server (NTRS)

    Munson, John C.

    1994-01-01

    This study is a direct result of an on-going project to model the reliability of a large real-time control avionics system. In previous modeling efforts with this system, hardware reliability models were applied in modeling the reliability behavior of this system. In an attempt to enhance the performance of the adapted reliability models, certain software attributes were introduced in these models to control for differences between programs and also sequential executions of the same program. As the basic nature of the software attributes that affect software reliability become better understood in the modeling process, this information begins to have important implications on the software development process. A significant problem arises when raw attribute measures are to be used in statistical models as predictors, for example, of measures of software quality. This is because many of the metrics are highly correlated. Consider the two attributes: lines of code, LOC, and number of program statements, Stmts. In this case, it is quite obvious that a program with a high value of LOC probably will also have a relatively high value of Stmts. In the case of low level languages, such as assembly language programs, there might be a one-to-one relationship between the statement count and the lines of code. When there is a complete absence of linear relationship among the metrics, they are said to be orthogonal or uncorrelated. Usually the lack of orthogonality is not serious enough to affect a statistical analysis. However, for the purposes of some statistical analysis such as multiple regression, the software metrics are so strongly interrelated that the regression results may be ambiguous and possibly even misleading. Typically, it is difficult to estimate the unique effects of individual software metrics in the regression equation. The estimated values of the coefficients are very sensitive to slight changes in the data and to the addition or deletion of variables in the regression equation. Since most of the existing metrics have common elements and are linear combinations of these common elements, it seems reasonable to investigate the structure of the underlying common factors or components that make up the raw metrics. The technique we have chosen to use to explore this structure is a procedure called principal components analysis. Principal components analysis is a decomposition technique that may be used to detect and analyze collinearity in software metrics. When confronted with a large number of metrics measuring a single construct, it may be desirable to represent the set by some smaller number of variables that convey all, or most, of the information in the original set. Principal components are linear transformations of a set of random variables that summarize the information contained in the variables. The transformations are chosen so that the first component accounts for the maximal amount of variation of the measures of any possible linear transform; the second component accounts for the maximal amount of residual variation; and so on. The principal components are constructed so that they represent transformed scores on dimensions that are orthogonal. Through the use of principal components analysis, it is possible to have a set of highly related software attributes mapped into a small number of uncorrelated attribute domains. This definitively solves the problem of multi-collinearity in subsequent regression analysis. There are many software metrics in the literature, but principal component analysis reveals that there are few distinct sources of variation, i.e. dimensions, in this set of metrics. It would appear perfectly reasonable to characterize the measurable attributes of a program with a simple function of a small number of orthogonal metrics each of which represents a distinct software attribute domain.

  6. Proceedings of Interservice/Industry Training Systems and Education Conference (16th) Held on 28 November -1 December 1994.

    DTIC Science & Technology

    1994-12-01

    be INTRODUCTION familiar: best value source selection, processes and metrics In simplified terms, acquisition and continuous improvement ; of a training ...pro- continuous improvement , MIL-STD- posed processes and metrics are 1379D, the systems approach to placed in the contract in a training , concurrent...identification and 5 Continuous Process Improvement correction of errors are critical to software product 6 Training correctness and quality. Correcting

  7. JPL's Real-Time Weather Processor project (RWP) metrics and observations at system completion

    NASA Technical Reports Server (NTRS)

    Loesh, Robert E.; Conover, Robert A.; Malhotra, Shan

    1990-01-01

    As an integral part of the overall upgraded National Airspace System (NAS), the objective of the Real-Time Weather Processor (RWP) project is to improve the quality of weather information and the timeliness of its dissemination to system users. To accomplish this, an RWP will be installed in each of the Center Weather Service Units (CWSUs), located in 21 of the 23 Air Route Traffic Control Centers (ARTCCs). The RWP System is a prototype system. It is planned that the software will be GFE and that production hardware will be acquired via industry competitive procurement. The ARTCC is a facility established to provide air traffic control service to aircraft operating on Instrument Flight Rules (IFR) flight plans within controlled airspace, principally during the en route phase of the flight. Covered here are requirement metrics, Software Problem Failure Reports (SPFRs), and Ada portability metrics and observations.

  8. Assessing the quality of restored images in optical long-baseline interferometry

    NASA Astrophysics Data System (ADS)

    Gomes, Nuno; Garcia, Paulo J. V.; Thiébaut, Éric

    2017-03-01

    Assessing the quality of aperture synthesis maps is relevant for benchmarking image reconstruction algorithms, for the scientific exploitation of data from optical long-baseline interferometers, and for the design/upgrade of new/existing interferometric imaging facilities. Although metrics have been proposed in these contexts, no systematic study has been conducted on the selection of a robust metric for quality assessment. This article addresses the question: what is the best metric to assess the quality of a reconstructed image? It starts by considering several metrics and selecting a few based on general properties. Then, a variety of image reconstruction cases are considered. The observational scenarios are phase closure and phase referencing at the Very Large Telescope Interferometer (VLTI), for a combination of two, three, four and six telescopes. End-to-end image reconstruction is accomplished with the MIRA software, and several merit functions are put to test. It is found that convolution by an effective point spread function is required for proper image quality assessment. The effective angular resolution of the images is superior to naive expectation based on the maximum frequency sampled by the array. This is due to the prior information used in the aperture synthesis algorithm and to the nature of the objects considered. The ℓ1-norm is the most robust of all considered metrics, because being linear it is less sensitive to image smoothing by high regularization levels. For the cases considered, this metric allows the implementation of automatic quality assessment of reconstructed images, with a performance similar to human selection.

  9. A comprehensive quality control workflow for paired tumor-normal NGS experiments.

    PubMed

    Schroeder, Christopher M; Hilke, Franz J; Löffler, Markus W; Bitzer, Michael; Lenz, Florian; Sturm, Marc

    2017-06-01

    Quality control (QC) is an important part of all NGS data analysis stages. Many available tools calculate QC metrics from different analysis steps of single sample experiments (raw reads, mapped reads and variant lists). Multi-sample experiments, as sequencing of tumor-normal pairs, require additional QC metrics to ensure validity of results. These multi-sample QC metrics still lack standardization. We therefore suggest a new workflow for QC of DNA sequencing of tumor-normal pairs. With this workflow well-known single-sample QC metrics and additional metrics specific for tumor-normal pairs can be calculated. The segmentation into different tools offers a high flexibility and allows reuse for other purposes. All tools produce qcML, a generic XML format for QC of -omics experiments. qcML uses quality metrics defined in an ontology, which was adapted for NGS. All QC tools are implemented in C ++ and run both under Linux and Windows. Plotting requires python 2.7 and matplotlib. The software is available under the 'GNU General Public License version 2' as part of the ngs-bits project: https://github.com/imgag/ngs-bits. christopher.schroeder@med.uni-tuebingen.de. Supplementary data are available at Bioinformatics online. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com

  10. Landscape pattern metrics and regional assessment

    USGS Publications Warehouse

    O'Neill, R. V.; Riitters, K.H.; Wickham, J.D.; Jones, K.B.

    1999-01-01

    The combination of remote imagery data, geographic information systems software, and landscape ecology theory provides a unique basis for monitoring and assessing large-scale ecological systems. The unique feature of the work has been the need to develop and interpret quantitative measures of spatial pattern-the landscape indices. This article reviews what is known about the statistical properties of these pattern metrics and suggests some additional metrics based on island biogeography, percolation theory, hierarchy theory, and economic geography. Assessment applications of this approach have required interpreting the pattern metrics in terms of specific environmental endpoints, such as wildlife and water quality, and research into how to represent synergystic effects of many overlapping sources of stress.

  11. Development of a Mammographic Image Processing Environment Using MATLAB.

    DTIC Science & Technology

    1994-12-01

    S. .° : i. .... ...... Correctness Reliability Efficiency Integrity Usability Figure 1.2 - McCall’s software quality factors [ Pressman , 1987] 1.4...quality factors [ Pressman , 1987] 3-13 Each quality factor itself is related to independent attributes called criteria [Cooper and Fisher, 1979], or...metrics by [ Pressman , 1987], that can be used to judge, define, and measure quality [Cooper and Fisher, 1979]. Figure 3.9 shows the criteria that are used

  12. Algal Attributes: An Autecological Classification of Algal Taxa Collected by the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Porter, Stephen D.

    2008-01-01

    Algae are excellent indicators of water-quality conditions, notably nutrient and organic enrichment, and also are indicators of major ion, dissolved oxygen, and pH concentrations and stream microhabitat conditions. The autecology, or physiological optima and tolerance, of algal species for various water-quality contaminants and conditions is relatively well understood for certain groups of freshwater algae, notably diatoms. However, applications of autecological information for water-quality assessments have been limited because of challenges associated with compiling autecological literature from disparate sources, tracking name changes for a large number of algal species, and creating an autecological data base from which algal-indicator metrics can be calculated. A comprehensive summary of algal autecological attributes for North American streams and rivers does not exist. This report describes a large, digital data file containing 28,182 records for 5,939 algal taxa, generally species or variety, collected by the U.S. Geological Survey?s National Water-Quality Assessment (NAWQA) Program. The data file includes 37 algal attributes classified by over 100 algal-indicator codes or metrics that can be calculated easily with readily available software. Algal attributes include qualitative classifications based on European and North American autecological literature, and semi-quantitative, weighted-average regression approaches for estimating optima using regional and national NAWQA data. Applications of algal metrics in water-quality assessments are discussed and national quartile distributions of metric scores are shown for selected indicator metrics.

  13. Agile deployment and code coverage testing metrics of the boot software on-board Solar Orbiter's Energetic Particle Detector

    NASA Astrophysics Data System (ADS)

    Parra, Pablo; da Silva, Antonio; Polo, Óscar R.; Sánchez, Sebastián

    2018-02-01

    In this day and age, successful embedded critical software needs agile and continuous development and testing procedures. This paper presents the overall testing and code coverage metrics obtained during the unit testing procedure carried out to verify the correctness of the boot software that will run in the Instrument Control Unit (ICU) of the Energetic Particle Detector (EPD) on-board Solar Orbiter. The ICU boot software is a critical part of the project so its verification should be addressed at an early development stage, so any test case missed in this process may affect the quality of the overall on-board software. According to the European Cooperation for Space Standardization ESA standards, testing this kind of critical software must cover 100% of the source code statement and decision paths. This leads to the complete testing of fault tolerance and recovery mechanisms that have to resolve every possible memory corruption or communication error brought about by the space environment. The introduced procedure enables fault injection from the beginning of the development process and enables to fulfill the exigent code coverage demands on the boot software.

  14. Metric Evaluation Pipeline for 3d Modeling of Urban Scenes

    NASA Astrophysics Data System (ADS)

    Bosch, M.; Leichtman, A.; Chilcott, D.; Goldberg, H.; Brown, M.

    2017-05-01

    Publicly available benchmark data and metric evaluation approaches have been instrumental in enabling research to advance state of the art methods for remote sensing applications in urban 3D modeling. Most publicly available benchmark datasets have consisted of high resolution airborne imagery and lidar suitable for 3D modeling on a relatively modest scale. To enable research in larger scale 3D mapping, we have recently released a public benchmark dataset with multi-view commercial satellite imagery and metrics to compare 3D point clouds with lidar ground truth. We now define a more complete metric evaluation pipeline developed as publicly available open source software to assess semantically labeled 3D models of complex urban scenes derived from multi-view commercial satellite imagery. Evaluation metrics in our pipeline include horizontal and vertical accuracy and completeness, volumetric completeness and correctness, perceptual quality, and model simplicity. Sources of ground truth include airborne lidar and overhead imagery, and we demonstrate a semi-automated process for producing accurate ground truth shape files to characterize building footprints. We validate our current metric evaluation pipeline using 3D models produced using open source multi-view stereo methods. Data and software is made publicly available to enable further research and planned benchmarking activities.

  15. Quantitative evaluation of software packages for single-molecule localization microscopy.

    PubMed

    Sage, Daniel; Kirshner, Hagai; Pengo, Thomas; Stuurman, Nico; Min, Junhong; Manley, Suliana; Unser, Michael

    2015-08-01

    The quality of super-resolution images obtained by single-molecule localization microscopy (SMLM) depends largely on the software used to detect and accurately localize point sources. In this work, we focus on the computational aspects of super-resolution microscopy and present a comprehensive evaluation of localization software packages. Our philosophy is to evaluate each package as a whole, thus maintaining the integrity of the software. We prepared synthetic data that represent three-dimensional structures modeled after biological components, taking excitation parameters, noise sources, point-spread functions and pixelation into account. We then asked developers to run their software on our data; most responded favorably, allowing us to present a broad picture of the methods available. We evaluated their results using quantitative and user-interpretable criteria: detection rate, accuracy, quality of image reconstruction, resolution, software usability and computational resources. These metrics reflect the various tradeoffs of SMLM software packages and help users to choose the software that fits their needs.

  16. System Engineering Concept Demonstration, System Engineering Needs. Volume 2

    DTIC Science & Technology

    1992-12-01

    changeability, and invisibility. "Software entities are perhaps more complex for their size than any other human construct..." In addition, software is... human actions and interactions that often fail or insufficient in large organizations. Specific needs in this area include the following: " Each...needed to accomplish incremental review and critique of information. * Automi ..-’ metrics support is needed for the measuring ikey quality aspects of

  17. Software for improving the quality of project management, a case study: international manufacture of electrical equipment

    NASA Astrophysics Data System (ADS)

    Preradović, D. M.; Mićić, Lj S.; Barz, C.

    2017-05-01

    Production conditions in today’s world require software support at every stage of production and development of new products, for quality assurance and compliance with ISO standards. In addition to ISO standards such as usual metrics of quality, companies today are focused on other optional standards, such as CMMI (Capability Maturity Model Integrated) or prescribing they own standards. However, while there is intensive progress being made in the PM (project management), there is still a significant number of projects, at the global level, that are failures. These have failed to achieve their goals, within budget or timeframe. This paper focuses on checking the role of software tools through the rate of success in projects implemented in the case of internationally manufactured electrical equipment. The results of this research show the level of contribution of the project management software used to manage and develop new products to improve PM processes and PM functions, and how selection of the software tools affects the quality of PM processes and successfully completed projects.

  18. FQC Dashboard: integrates FastQC results into a web-based, interactive, and extensible FASTQ quality control tool

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, Joseph; Pirrung, Meg; McCue, Lee Ann

    FQC is software that facilitates quality control of FASTQ files by carrying out a QC protocol using FastQC, parsing results, and aggregating quality metrics into an interactive dashboard designed to richly summarize individual sequencing runs. The dashboard groups samples in dropdowns for navigation among the data sets, utilizes human-readable configuration files to manipulate the pages and tabs, and is extensible with CSV data.

  19. FQC Dashboard: integrates FastQC results into a web-based, interactive, and extensible FASTQ quality control tool

    DOE PAGES

    Brown, Joseph; Pirrung, Meg; McCue, Lee Ann

    2017-06-09

    FQC is software that facilitates quality control of FASTQ files by carrying out a QC protocol using FastQC, parsing results, and aggregating quality metrics into an interactive dashboard designed to richly summarize individual sequencing runs. The dashboard groups samples in dropdowns for navigation among the data sets, utilizes human-readable configuration files to manipulate the pages and tabs, and is extensible with CSV data.

  20. User's Manual for the National Water-Quality Assessment Program Invertebrate Data Analysis System (IDAS) Software: Version 3

    USGS Publications Warehouse

    Cuffney, Thomas F.

    2003-01-01

    The Invertebrate Data Analysis System (IDAS) software provides an accurate, consistent, and efficient mechanism for analyzing invertebrate data collected as part of the National Water-Quality Assessment Program and stored in the Biological Transactional Database (Bio-TDB). The IDAS software is a stand-alone program for personal computers that run Microsoft (MS) Windows?. It allows users to read data downloaded from Bio-TDB and stored either as MS Excel? or MS Access? files. The program consists of five modules. The Edit Data module allows the user to subset, combine, delete, and summarize community data. The Data Preparation module allows the user to select the type(s) of sample(s) to process, calculate densities, delete taxa based on laboratory processing notes, combine lifestages or keep them separate, select a lowest taxonomic level for analysis, delete rare taxa, and resolve taxonomic ambiguities. The Calculate Community Metrics module allows the user to calculate over 130 community metrics, including metrics based on organism tolerances and functional feeding groups. The Calculate Diversities and Similarities module allows the user to calculate nine diversity and eight similarity indices. The Data export module allows the user to export data to other software packages and produce tables of community data that can be imported into spreadsheet and word-processing programs. Though the IDAS program was developed to process invertebrate data downloaded from USGS databases, it will work with other data sets that are converted to the USGS (Bio-TDB) format. Consequently, the data manipulation, analysis, and export procedures provided by the IDAS program can be used by anyone involved in using benthic macroinvertebrates in applied or basic research.

  1. Metrics of Software Quality.

    DTIC Science & Technology

    1980-11-01

    Systems: A Raytheon Project History", RADC-TR-77-188, Final Technical Report, June 1977. 4. IBM Federal Systems Division, "Statistical Prediction of...147, June 1979. 4. W. D. Brooks, R. W. Motley, "Analysis of Discrete Software Reliability Models", IBM Corp., RADC-TR-80-84, RADC, New York, April 1980...J. C. King of IBM (Reference 9) and Lori A. Clark (Reference 10) of the University of Massachusetts. Programs, so exercised must be augmented so they

  2. Extensibility Experiments with the Software Life-Cycle Support Environment

    DTIC Science & Technology

    1991-11-01

    APRICOT ) and Bit- Oriented Message Definer (BMD); and three from the Ada Software Repository (ASR) at White Sands-the NASA/Goddard Space Flight Center...Graphical Kernel System (GKS). c. AMS - The Automated Measurement System tool supports the definition, collec- tion, and reporting of quality metric...Ada Primitive Order Compilation Order Tool ( APRICOT ) 2. Bit-Oriented Message Definer (BMD) 3. LGEN: A Language Generator Tool 4. I"ilc Chc-ker 5

  3. MO-PIS-Exhibit Hall-01: Tools for TG-142 Linac Imaging QA I

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clements, M; Wiesmeyer, M

    2014-06-15

    Partners in Solutions is an exciting new program in which AAPM partners with our vendors to present practical “hands-on” information about the equipment and software systems that we use in our clinics. The therapy topic this year is solutions for TG-142 recommendations for linear accelerator imaging QA. Note that the sessions are being held in a special purpose room built on the Exhibit Hall Floor, to encourage further interaction with the vendors. Automated Imaging QA for TG-142 with RIT Presentation Time: 2:45 – 3:15 PM This presentation will discuss software tools for automated imaging QA and phantom analysis for TG-142.more » All modalities used in radiation oncology will be discussed, including CBCT, planar kV imaging, planar MV imaging, and imaging and treatment coordinate coincidence. Vendor supplied phantoms as well as a variety of third-party phantoms will be shown, along with appropriate analyses, proper phantom setup procedures and scanning settings, and a discussion of image quality metrics. Tools for process automation will be discussed which include: RIT Cognition (machine learning for phantom image identification), RIT Cerberus (automated file system monitoring and searching), and RunQueueC (batch processing of multiple images). In addition to phantom analysis, tools for statistical tracking, trending, and reporting will be discussed. This discussion will include an introduction to statistical process control, a valuable tool in analyzing data and determining appropriate tolerances. An Introduction to TG-142 Imaging QA Using Standard Imaging Products Presentation Time: 3:15 – 3:45 PM Medical Physicists want to understand the logic behind TG-142 Imaging QA. What is often missing is a firm understanding of the connections between the EPID and OBI phantom imaging, the software “algorithms” that calculate the QA metrics, the establishment of baselines, and the analysis and interpretation of the results. The goal of our brief presentation will be to establish and solidify these connections. Our talk will be motivated by the Standard Imaging, Inc. phantom and software solutions. We will present and explain each of the image quality metrics in TG-142 in terms of the theory, mathematics, and algorithms used to implement them in the Standard Imaging PIPSpro software. In the process, we will identify the regions of phantom images that are analyzed by each algorithm. We then will discuss the process of the creation of baselines and typical ranges of acceptable values for each imaging quality metric.« less

  4. Software engineering and Ada in design

    NASA Technical Reports Server (NTRS)

    Oneill, Don

    1986-01-01

    Modern software engineering promises significant reductions in software costs and improvements in software quality. The Ada language is the focus for these software methodology and tool improvements. The IBM FSD approach, including the software engineering practices that guide the systematic design and development of software products and the management of the software process are examined. The revised Ada design language adaptation is revealed. This four level design methodology is detailed including the purpose of each level, the management strategy that integrates the software design activity with the program milestones, and the technical strategy that maps the Ada constructs to each level of design. A complete description of each design level is provided along with specific design language recording guidelines for each level. Finally, some testimony is offered on education, tools, architecture, and metrics resulting from project use of the four level Ada design language adaptation.

  5. Recommendations for Mass Spectrometry Data Quality Metrics for Open Access Data (Corollary to the Amsterdam Principles)

    PubMed Central

    Kinsinger, Christopher R.; Apffel, James; Baker, Mark; Bian, Xiaopeng; Borchers, Christoph H.; Bradshaw, Ralph; Brusniak, Mi-Youn; Chan, Daniel W.; Deutsch, Eric W.; Domon, Bruno; Gorman, Jeff; Grimm, Rudolf; Hancock, William; Hermjakob, Henning; Horn, David; Hunter, Christie; Kolar, Patrik; Kraus, Hans-Joachim; Langen, Hanno; Linding, Rune; Moritz, Robert L.; Omenn, Gilbert S.; Orlando, Ron; Pandey, Akhilesh; Ping, Peipei; Rahbar, Amir; Rivers, Robert; Seymour, Sean L.; Simpson, Richard J.; Slotta, Douglas; Smith, Richard D.; Stein, Stephen E.; Tabb, David L.; Tagle, Danilo; Yates, John R.; Rodriguez, Henry

    2011-01-01

    Policies supporting the rapid and open sharing of proteomic data are being implemented by the leading journals in the field. The proteomics community is taking steps to ensure that data are made publicly accessible and are of high quality, a challenging task that requires the development and deployment of methods for measuring and documenting data quality metrics. On September 18, 2010, the U.S. National Cancer Institute (NCI) convened the “International Workshop on Proteomic Data Quality Metrics” in Sydney, Australia, to identify and address issues facing the development and use of such methods for open access proteomics data. The stakeholders at the workshop enumerated the key principles underlying a framework for data quality assessment in mass spectrometry data that will meet the needs of the research community, journals, funding agencies, and data repositories. Attendees discussed and agreed up on two primary needs for the wide use of quality metrics: (1) an evolving list of comprehensive quality metrics and (2) standards accompanied by software analytics. Attendees stressed the importance of increased education and training programs to promote reliable protocols in proteomics. This workshop report explores the historic precedents, key discussions, and necessary next steps to enhance the quality of open access data. By agreement, this article is published simultaneously in the Journal of Proteome Research, Molecular and Cellular Proteomics, Proteomics, and Proteomics Clinical Applications as a public service to the research community. The peer review process was a coordinated effort conducted by a panel of referees selected by the journals. PMID:22053864

  6. Recommendations for Mass Spectrometry Data Quality Metrics for Open Access Data (Corollary to the Amsterdam Principles)*

    PubMed Central

    Kinsinger, Christopher R.; Apffel, James; Baker, Mark; Bian, Xiaopeng; Borchers, Christoph H.; Bradshaw, Ralph; Brusniak, Mi-Youn; Chan, Daniel W.; Deutsch, Eric W.; Domon, Bruno; Gorman, Jeff; Grimm, Rudolf; Hancock, William; Hermjakob, Henning; Horn, David; Hunter, Christie; Kolar, Patrik; Kraus, Hans-Joachim; Langen, Hanno; Linding, Rune; Moritz, Robert L.; Omenn, Gilbert S.; Orlando, Ron; Pandey, Akhilesh; Ping, Peipei; Rahbar, Amir; Rivers, Robert; Seymour, Sean L.; Simpson, Richard J.; Slotta, Douglas; Smith, Richard D.; Stein, Stephen E.; Tabb, David L.; Tagle, Danilo; Yates, John R.; Rodriguez, Henry

    2011-01-01

    Policies supporting the rapid and open sharing of proteomic data are being implemented by the leading journals in the field. The proteomics community is taking steps to ensure that data are made publicly accessible and are of high quality, a challenging task that requires the development and deployment of methods for measuring and documenting data quality metrics. On September 18, 2010, the United States National Cancer Institute convened the “International Workshop on Proteomic Data Quality Metrics” in Sydney, Australia, to identify and address issues facing the development and use of such methods for open access proteomics data. The stakeholders at the workshop enumerated the key principles underlying a framework for data quality assessment in mass spectrometry data that will meet the needs of the research community, journals, funding agencies, and data repositories. Attendees discussed and agreed up on two primary needs for the wide use of quality metrics: 1) an evolving list of comprehensive quality metrics and 2) standards accompanied by software analytics. Attendees stressed the importance of increased education and training programs to promote reliable protocols in proteomics. This workshop report explores the historic precedents, key discussions, and necessary next steps to enhance the quality of open access data. By agreement, this article is published simultaneously in the Journal of Proteome Research, Molecular and Cellular Proteomics, Proteomics, and Proteomics Clinical Applications as a public service to the research community. The peer review process was a coordinated effort conducted by a panel of referees selected by the journals. PMID:22052993

  7. An Improved Suite of Object Oriented Software Measures

    NASA Technical Reports Server (NTRS)

    Neal, Ralph D.; Weistroffer, H. Roland; Coppins, Richard J.

    1997-01-01

    In the pursuit of ever increasing productivity, the need to be able to measure specific aspects of software is generally agreed upon. As object oriented programming languages are becoming more and more widely used, metrics specifically designed for object oriented software are required. In recent years there has been an explosion of new, object oriented software metrics proposed in the literature. Unfortunately, many or most of these proposed metrics have not been validated to measure what they claim to measure. In fact, an analysis of many of these metrics shows that they do not satisfy basic properties of measurement theory, and thus their application has to be suspect. In this paper ten improved metrics are proposed and are validated using measurement theory.

  8. A bridge role metric model for nodes in software networks.

    PubMed

    Li, Bo; Feng, Yanli; Ge, Shiyu; Li, Dashe

    2014-01-01

    A bridge role metric model is put forward in this paper. Compared with previous metric models, our solution of a large-scale object-oriented software system as a complex network is inherently more realistic. To acquire nodes and links in an undirected network, a new model that presents the crucial connectivity of a module or the hub instead of only centrality as in previous metric models is presented. Two previous metric models are described for comparison. In addition, it is obvious that the fitting curve between the Bre results and degrees can well be fitted by a power law. The model represents many realistic characteristics of actual software structures, and a hydropower simulation system is taken as an example. This paper makes additional contributions to an accurate understanding of module design of software systems and is expected to be beneficial to software engineering practices.

  9. A Bridge Role Metric Model for Nodes in Software Networks

    PubMed Central

    Li, Bo; Feng, Yanli; Ge, Shiyu; Li, Dashe

    2014-01-01

    A bridge role metric model is put forward in this paper. Compared with previous metric models, our solution of a large-scale object-oriented software system as a complex network is inherently more realistic. To acquire nodes and links in an undirected network, a new model that presents the crucial connectivity of a module or the hub instead of only centrality as in previous metric models is presented. Two previous metric models are described for comparison. In addition, it is obvious that the fitting curve between the results and degrees can well be fitted by a power law. The model represents many realistic characteristics of actual software structures, and a hydropower simulation system is taken as an example. This paper makes additional contributions to an accurate understanding of module design of software systems and is expected to be beneficial to software engineering practices. PMID:25364938

  10. Simultaneous Analysis and Quality Assurance for Diffusion Tensor Imaging

    PubMed Central

    Lauzon, Carolyn B.; Asman, Andrew J.; Esparza, Michael L.; Burns, Scott S.; Fan, Qiuyun; Gao, Yurui; Anderson, Adam W.; Davis, Nicole; Cutting, Laurie E.; Landman, Bennett A.

    2013-01-01

    Diffusion tensor imaging (DTI) enables non-invasive, cyto-architectural mapping of in vivo tissue microarchitecture through voxel-wise mathematical modeling of multiple magnetic resonance imaging (MRI) acquisitions, each differently sensitized to water diffusion. DTI computations are fundamentally estimation processes and are sensitive to noise and artifacts. Despite widespread adoption in the neuroimaging community, maintaining consistent DTI data quality remains challenging given the propensity for patient motion, artifacts associated with fast imaging techniques, and the possibility of hardware changes/failures. Furthermore, the quantity of data acquired per voxel, the non-linear estimation process, and numerous potential use cases complicate traditional visual data inspection approaches. Currently, quality inspection of DTI data has relied on visual inspection and individual processing in DTI analysis software programs (e.g. DTIPrep, DTI-studio). However, recent advances in applied statistical methods have yielded several different metrics to assess noise level, artifact propensity, quality of tensor fit, variance of estimated measures, and bias in estimated measures. To date, these metrics have been largely studied in isolation. Herein, we select complementary metrics for integration into an automatic DTI analysis and quality assurance pipeline. The pipeline completes in 24 hours, stores statistical outputs, and produces a graphical summary quality analysis (QA) report. We assess the utility of this streamlined approach for empirical quality assessment on 608 DTI datasets from pediatric neuroimaging studies. The efficiency and accuracy of quality analysis using the proposed pipeline is compared with quality analysis based on visual inspection. The unified pipeline is found to save a statistically significant amount of time (over 70%) while improving the consistency of QA between a DTI expert and a pool of research associates. Projection of QA metrics to a low dimensional manifold reveal qualitative, but clear, QA-study associations and suggest that automated outlier/anomaly detection would be feasible. PMID:23637895

  11. Simultaneous analysis and quality assurance for diffusion tensor imaging.

    PubMed

    Lauzon, Carolyn B; Asman, Andrew J; Esparza, Michael L; Burns, Scott S; Fan, Qiuyun; Gao, Yurui; Anderson, Adam W; Davis, Nicole; Cutting, Laurie E; Landman, Bennett A

    2013-01-01

    Diffusion tensor imaging (DTI) enables non-invasive, cyto-architectural mapping of in vivo tissue microarchitecture through voxel-wise mathematical modeling of multiple magnetic resonance imaging (MRI) acquisitions, each differently sensitized to water diffusion. DTI computations are fundamentally estimation processes and are sensitive to noise and artifacts. Despite widespread adoption in the neuroimaging community, maintaining consistent DTI data quality remains challenging given the propensity for patient motion, artifacts associated with fast imaging techniques, and the possibility of hardware changes/failures. Furthermore, the quantity of data acquired per voxel, the non-linear estimation process, and numerous potential use cases complicate traditional visual data inspection approaches. Currently, quality inspection of DTI data has relied on visual inspection and individual processing in DTI analysis software programs (e.g. DTIPrep, DTI-studio). However, recent advances in applied statistical methods have yielded several different metrics to assess noise level, artifact propensity, quality of tensor fit, variance of estimated measures, and bias in estimated measures. To date, these metrics have been largely studied in isolation. Herein, we select complementary metrics for integration into an automatic DTI analysis and quality assurance pipeline. The pipeline completes in 24 hours, stores statistical outputs, and produces a graphical summary quality analysis (QA) report. We assess the utility of this streamlined approach for empirical quality assessment on 608 DTI datasets from pediatric neuroimaging studies. The efficiency and accuracy of quality analysis using the proposed pipeline is compared with quality analysis based on visual inspection. The unified pipeline is found to save a statistically significant amount of time (over 70%) while improving the consistency of QA between a DTI expert and a pool of research associates. Projection of QA metrics to a low dimensional manifold reveal qualitative, but clear, QA-study associations and suggest that automated outlier/anomaly detection would be feasible.

  12. Models and metrics for software management and engineering

    NASA Technical Reports Server (NTRS)

    Basili, V. R.

    1988-01-01

    This paper attempts to characterize and present a state of the art view of several quantitative models and metrics of the software life cycle. These models and metrics can be used to aid in managing and engineering software projects. They deal with various aspects of the software process and product, including resources allocation and estimation, changes and errors, size, complexity and reliability. Some indication is given of the extent to which the various models have been used and the success they have achieved.

  13. Sound quality evaluation of air conditioning sound rating metric

    NASA Astrophysics Data System (ADS)

    Hodgdon, Kathleen K.; Peters, Jonathan A.; Burkhardt, Russell C.; Atchley, Anthony A.; Blood, Ingrid M.

    2003-10-01

    A product's success can depend on its acoustic signature as much as on the product's performance. The consumer's perception can strongly influence their satisfaction with and confidence in the product. A metric that can rate the content of the spectrum, and predict its consumer preference, is a valuable tool for manufacturers. The current method of assessing acoustic signatures from residential air conditioning units is defined in the Air Conditioning and Refrigeration Institute (ARI 270) 1995 Standard for Sound Rating of Outdoor Unitary Equipment. The ARI 270 metric, and modified versions of that metric, were implemented in software with the flexibility to modify the features applied. Numerous product signatures were analyzed to generate a set of synthesized spectra that targeted spectral configurations that challenged the metric's abilities. A subjective jury evaluation was conducted to establish the consumer preference for those spectra. Statistical correlations were conducted to assess the degree of relationship between the subjective preferences and the various metric calculations. Recommendations were made for modifications to improve the current metric's ability to predict subjective preference. [Research supported by the Air Conditioning and Refrigeration Institute.

  14. Evaluation of cassette-based digital radiography detectors using standardized image quality metrics: AAPM TG-150 Draft Image Detector Tests.

    PubMed

    Li, Guang; Greene, Travis C; Nishino, Thomas K; Willis, Charles E

    2016-09-08

    The purpose of this study was to evaluate several of the standardized image quality metrics proposed by the American Association of Physics in Medicine (AAPM) Task Group 150. The task group suggested region-of-interest (ROI)-based techniques to measure nonuniformity, minimum signal-to-noise ratio (SNR), number of anomalous pixels, and modulation transfer function (MTF). This study evaluated the effects of ROI size and layout on the image metrics by using four different ROI sets, assessed result uncertainty by repeating measurements, and compared results with two commercially available quality control tools, namely the Carestream DIRECTVIEW Total Quality Tool (TQT) and the GE Healthcare Quality Assurance Process (QAP). Seven Carestream DRX-1C (CsI) detectors on mobile DR systems and four GE FlashPad detectors in radiographic rooms were tested. Images were analyzed using MATLAB software that had been previously validated and reported. Our values for signal and SNR nonuniformity and MTF agree with values published by other investigators. Our results show that ROI size affects nonuniformity and minimum SNR measurements, but not detection of anomalous pixels. Exposure geometry affects all tested image metrics except for the MTF. TG-150 metrics in general agree with the TQT, but agree with the QAP only for local and global signal nonuniformity. The difference in SNR nonuniformity and MTF values between the TG-150 and QAP may be explained by differences in the calculation of noise and acquisition beam quality, respectively. TG-150's SNR nonuniformity metrics are also more sensitive to detector nonuniformity compared to the QAP. Our results suggest that fixed ROI size should be used for consistency because nonuniformity metrics depend on ROI size. Ideally, detector tests should be performed at the exact calibration position. If not feasible, a baseline should be established from the mean of several repeated measurements. Our study indicates that the TG-150 tests can be used as an independent standardized procedure for detector performance assessment. © 2016 The Authors.

  15. Evaluation of cassette‐based digital radiography detectors using standardized image quality metrics: AAPM TG‐150 Draft Image Detector Tests

    PubMed Central

    Greene, Travis C.; Nishino, Thomas K.; Willis, Charles E.

    2016-01-01

    The purpose of this study was to evaluate several of the standardized image quality metrics proposed by the American Association of Physics in Medicine (AAPM) Task Group 150. The task group suggested region‐of‐interest (ROI)‐based techniques to measure nonuniformity, minimum signal‐to‐noise ratio (SNR), number of anomalous pixels, and modulation transfer function (MTF). This study evaluated the effects of ROI size and layout on the image metrics by using four different ROI sets, assessed result uncertainty by repeating measurements, and compared results with two commercially available quality control tools, namely the Carestream DIRECTVIEW Total Quality Tool (TQT) and the GE Healthcare Quality Assurance Process (QAP). Seven Carestream DRX‐1C (CsI) detectors on mobile DR systems and four GE FlashPad detectors in radiographic rooms were tested. Images were analyzed using MATLAB software that had been previously validated and reported. Our values for signal and SNR nonuniformity and MTF agree with values published by other investigators. Our results show that ROI size affects nonuniformity and minimum SNR measurements, but not detection of anomalous pixels. Exposure geometry affects all tested image metrics except for the MTF. TG‐150 metrics in general agree with the TQT, but agree with the QAP only for local and global signal nonuniformity. The difference in SNR nonuniformity and MTF values between the TG‐150 and QAP may be explained by differences in the calculation of noise and acquisition beam quality, respectively. TG‐150's SNR nonuniformity metrics are also more sensitive to detector nonuniformity compared to the QAP. Our results suggest that fixed ROI size should be used for consistency because nonuniformity metrics depend on ROI size. Ideally, detector tests should be performed at the exact calibration position. If not feasible, a baseline should be established from the mean of several repeated measurements. Our study indicates that the TG‐150 tests can be used as an independent standardized procedure for detector performance assessment. PACS number(s): 87.57.‐s, 87.57.C PMID:27685102

  16. Despeckle filtering software toolbox for ultrasound imaging of the common carotid artery.

    PubMed

    Loizou, Christos P; Theofanous, Charoula; Pantziaris, Marios; Kasparis, Takis

    2014-04-01

    Ultrasound imaging of the common carotid artery (CCA) is a non-invasive tool used in medicine to assess the severity of atherosclerosis and monitor its progression through time. It is also used in border detection and texture characterization of the atherosclerotic carotid plaque in the CCA, the identification and measurement of the intima-media thickness (IMT) and the lumen diameter that all are very important in the assessment of cardiovascular disease (CVD). Visual perception, however, is hindered by speckle, a multiplicative noise, that degrades the quality of ultrasound B-mode imaging. Noise reduction is therefore essential for improving the visual observation quality or as a pre-processing step for further automated analysis, such as image segmentation of the IMT and the atherosclerotic carotid plaque in ultrasound images. In order to facilitate this preprocessing step, we have developed in MATLAB(®) a unified toolbox that integrates image despeckle filtering (IDF), texture analysis and image quality evaluation techniques to automate the pre-processing and complement the disease evaluation in ultrasound CCA images. The proposed software, is based on a graphical user interface (GUI) and incorporates image normalization, 10 different despeckle filtering techniques (DsFlsmv, DsFwiener, DsFlsminsc, DsFkuwahara, DsFgf, DsFmedian, DsFhmedian, DsFad, DsFnldif, DsFsrad), image intensity normalization, 65 texture features, 15 quantitative image quality metrics and objective image quality evaluation. The software is publicly available in an executable form, which can be downloaded from http://www.cs.ucy.ac.cy/medinfo/. It was validated on 100 ultrasound images of the CCA, by comparing its results with quantitative visual analysis performed by a medical expert. It was observed that the despeckle filters DsFlsmv, and DsFhmedian improved image quality perception (based on the expert's assessment and the image texture and quality metrics). It is anticipated that the system could help the physician in the assessment of cardiovascular image analysis. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  17. WISE: Automated support for software project management and measurement. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Ramakrishnan, Sudhakar

    1995-01-01

    One important aspect of software development and IV&V is measurement. Unless a software development effort is measured in some way, it is difficult to judge the effectiveness of current efforts and predict future performances. Collection of metrics and adherence to a process are difficult tasks in a software project. Change activity is a powerful indicator of project status. Automated systems that can handle change requests, issues, and other process documents provide an excellent platform for tracking the status of the project. A World Wide Web based architecture is developed for (a) making metrics collection an implicit part of the software process, (b) providing metric analysis dynamically, (c) supporting automated tools that can complement current practices of in-process improvement, and (d) overcoming geographical barrier. An operational system (WISE) instantiates this architecture allowing for the improvement of software process in a realistic environment. The tool tracks issues in software development process, provides informal communication between the users with different roles, supports to-do lists (TDL), and helps in software process improvement. WISE minimizes the time devoted to metrics collection, analysis, and captures software change data. Automated tools like WISE focus on understanding and managing the software process. The goal is improvement through measurement.

  18. Validation of neural spike sorting algorithms without ground-truth information.

    PubMed

    Barnett, Alex H; Magland, Jeremy F; Greengard, Leslie F

    2016-05-01

    The throughput of electrophysiological recording is growing rapidly, allowing thousands of simultaneous channels, and there is a growing variety of spike sorting algorithms designed to extract neural firing events from such data. This creates an urgent need for standardized, automatic evaluation of the quality of neural units output by such algorithms. We introduce a suite of validation metrics that assess the credibility of a given automatic spike sorting algorithm applied to a given dataset. By rerunning the spike sorter two or more times, the metrics measure stability under various perturbations consistent with variations in the data itself, making no assumptions about the internal workings of the algorithm, and minimal assumptions about the noise. We illustrate the new metrics on standard sorting algorithms applied to both in vivo and ex vivo recordings, including a time series with overlapping spikes. We compare the metrics to existing quality measures, and to ground-truth accuracy in simulated time series. We provide a software implementation. Metrics have until now relied on ground-truth, simulated data, internal algorithm variables (e.g. cluster separation), or refractory violations. By contrast, by standardizing the interface, our metrics assess the reliability of any automatic algorithm without reference to internal variables (e.g. feature space) or physiological criteria. Stability is a prerequisite for reproducibility of results. Such metrics could reduce the significant human labor currently spent on validation, and should form an essential part of large-scale automated spike sorting and systematic benchmarking of algorithms. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Water Network Tool for Resilience v. 1.0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2015-12-09

    WNTR is a python package designed to simulate and analyze resilience of water distribution networks. The software includes: - Pressure driven and demand driven hydraulic simulation - Water quality simulation to track concentration, trace, and water age - Conditional controls to simulate power outages - Models to simulate pipe breaks - A wide range of resilience metrics - Analysis and visualization tools

  20. User's manual for the National Water-Quality Assessment Program Invertebrate Data Analysis System (IDAS) software, version 5

    USGS Publications Warehouse

    Cuffney, Thomas F.; Brightbill, Robin A.

    2011-01-01

    The Invertebrate Data Analysis System (IDAS) software was developed to provide an accurate, consistent, and efficient mechanism for analyzing invertebrate data collected as part of the U.S. Geological Survey National Water-Quality Assessment (NAWQA) Program. The IDAS software is a stand-alone program for personal computers that run Microsoft Windows(Registered). It allows users to read data downloaded from the NAWQA Program Biological Transactional Database (Bio-TDB) or to import data from other sources either as Microsoft Excel(Registered) or Microsoft Access(Registered) files. The program consists of five modules: Edit Data, Data Preparation, Calculate Community Metrics, Calculate Diversities and Similarities, and Data Export. The Edit Data module allows the user to subset data on the basis of taxonomy or sample type, extract a random subsample of data, combine or delete data, summarize distributions, resolve ambiguous taxa (see glossary) and conditional/provisional taxa, import non-NAWQA data, and maintain and create files of invertebrate attributes that are used in the calculation of invertebrate metrics. The Data Preparation module allows the user to select the type(s) of sample(s) to process, calculate densities, delete taxa on the basis of laboratory processing notes, delete pupae or terrestrial adults, combine lifestages or keep them separate, select a lowest taxonomic level for analysis, delete rare taxa on the basis of the number of sites where a taxon occurs and (or) the abundance of a taxon in a sample, and resolve taxonomic ambiguities by one of four methods. The Calculate Community Metrics module allows the user to calculate 184 community metrics, including metrics based on organism tolerances, functional feeding groups, and behavior. The Calculate Diversities and Similarities module allows the user to calculate nine diversity and eight similarity indices. The Data Export module allows the user to export data to other software packages (CANOCO, Primer, PC-ORD, MVSP) and produce tables of community data that can be imported into spreadsheet, database, graphics, statistics, and word-processing programs. The IDAS program facilitates the documentation of analyses by keeping a log of the data that are processed, the files that are generated, and the program settings used to process the data. Though the IDAS program was developed to process NAWQA Program invertebrate data downloaded from Bio-TDB, the Edit Data module includes tools that can be used to convert non-NAWQA data into Bio-TDB format. Consequently, the data manipulation, analysis, and export procedures provided by the IDAS program can be used to process data generated outside of the NAWQA Program.

  1. The Harvard Automated Processing Pipeline for Electroencephalography (HAPPE): Standardized Processing Software for Developmental and High-Artifact Data.

    PubMed

    Gabard-Durnam, Laurel J; Mendez Leal, Adriana S; Wilkinson, Carol L; Levin, April R

    2018-01-01

    Electroenchephalography (EEG) recordings collected with developmental populations present particular challenges from a data processing perspective. These EEGs have a high degree of artifact contamination and often short recording lengths. As both sample sizes and EEG channel densities increase, traditional processing approaches like manual data rejection are becoming unsustainable. Moreover, such subjective approaches preclude standardized metrics of data quality, despite the heightened importance of such measures for EEGs with high rates of initial artifact contamination. There is presently a paucity of automated resources for processing these EEG data and no consistent reporting of data quality measures. To address these challenges, we propose the Harvard Automated Processing Pipeline for EEG (HAPPE) as a standardized, automated pipeline compatible with EEG recordings of variable lengths and artifact contamination levels, including high-artifact and short EEG recordings from young children or those with neurodevelopmental disorders. HAPPE processes event-related and resting-state EEG data from raw files through a series of filtering, artifact rejection, and re-referencing steps to processed EEG suitable for time-frequency-domain analyses. HAPPE also includes a post-processing report of data quality metrics to facilitate the evaluation and reporting of data quality in a standardized manner. Here, we describe each processing step in HAPPE, perform an example analysis with EEG files we have made freely available, and show that HAPPE outperforms seven alternative, widely-used processing approaches. HAPPE removes more artifact than all alternative approaches while simultaneously preserving greater or equivalent amounts of EEG signal in almost all instances. We also provide distributions of HAPPE's data quality metrics in an 867 file dataset as a reference distribution and in support of HAPPE's performance across EEG data with variable artifact contamination and recording lengths. HAPPE software is freely available under the terms of the GNU General Public License at https://github.com/lcnhappe/happe.

  2. The Harvard Automated Processing Pipeline for Electroencephalography (HAPPE): Standardized Processing Software for Developmental and High-Artifact Data

    PubMed Central

    Gabard-Durnam, Laurel J.; Mendez Leal, Adriana S.; Wilkinson, Carol L.; Levin, April R.

    2018-01-01

    Electroenchephalography (EEG) recordings collected with developmental populations present particular challenges from a data processing perspective. These EEGs have a high degree of artifact contamination and often short recording lengths. As both sample sizes and EEG channel densities increase, traditional processing approaches like manual data rejection are becoming unsustainable. Moreover, such subjective approaches preclude standardized metrics of data quality, despite the heightened importance of such measures for EEGs with high rates of initial artifact contamination. There is presently a paucity of automated resources for processing these EEG data and no consistent reporting of data quality measures. To address these challenges, we propose the Harvard Automated Processing Pipeline for EEG (HAPPE) as a standardized, automated pipeline compatible with EEG recordings of variable lengths and artifact contamination levels, including high-artifact and short EEG recordings from young children or those with neurodevelopmental disorders. HAPPE processes event-related and resting-state EEG data from raw files through a series of filtering, artifact rejection, and re-referencing steps to processed EEG suitable for time-frequency-domain analyses. HAPPE also includes a post-processing report of data quality metrics to facilitate the evaluation and reporting of data quality in a standardized manner. Here, we describe each processing step in HAPPE, perform an example analysis with EEG files we have made freely available, and show that HAPPE outperforms seven alternative, widely-used processing approaches. HAPPE removes more artifact than all alternative approaches while simultaneously preserving greater or equivalent amounts of EEG signal in almost all instances. We also provide distributions of HAPPE's data quality metrics in an 867 file dataset as a reference distribution and in support of HAPPE's performance across EEG data with variable artifact contamination and recording lengths. HAPPE software is freely available under the terms of the GNU General Public License at https://github.com/lcnhappe/happe. PMID:29535597

  3. SU-E-T-616: Plan Quality Assessment of Both Treatment Planning System Dose and Measurement-Based 3D Reconstructed Dose in the Patient

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Olch, A

    2015-06-15

    Purpose: Systematic radiotherapy plan quality assessment promotes quality improvement. Software tools can perform this analysis by applying site-specific structure dose metrics. The next step is to similarly evaluate the quality of the dose delivery. This study defines metrics for acceptable doses to targets and normal organs for a particular treatment site and scores each plan accordingly. The input can be the TPS or the measurement-based 3D patient dose. From this analysis, one can determine whether the delivered dose distribution to the patient receives a score which is comparable to the TPS plan score, otherwise replanning may be indicated. Methods: Elevenmore » neuroblastoma patient plans were exported from Eclipse to the Quality Reports program. A scoring algorithm defined a score for each normal and target structure based on dose-volume parameters. Each plan was scored by this algorithm and the percentage of total possible points was obtained. Each plan also underwent IMRT QA measurements with a Mapcheck2 or ArcCheck. These measurements were input into the 3DVH program to compute the patient 3D dose distribution which was analyzed using the same scoring algorithm as the TPS plan. Results: The mean quality score for the TPS plans was 75.37% (std dev=14.15%) compared to 71.95% (std dev=13.45%) for the 3DVH dose distribution. For 3/11 plans, the 3DVH-based quality score was higher than the TPS score, by between 0.5 to 8.4 percentage points. Eight/11 plans scores decreased based on IMRT QA measurements by 1.2 to 18.6 points. Conclusion: Software was used to determine the degree to which the plan quality score differed between the TPS and measurement-based dose. Although the delivery score was generally in good agreement with the planned dose score, there were some that improved while there was one plan whose delivered dose quality was significantly less than planned. This methodology helps evaluate both planned and delivered dose quality. Sun Nuclear Corporation has provded a license for the software described.« less

  4. Development of a software for quantitative evaluation radiotherapy target and organ-at-risk segmentation comparison.

    PubMed

    Kalpathy-Cramer, Jayashree; Awan, Musaddiq; Bedrick, Steven; Rasch, Coen R N; Rosenthal, David I; Fuller, Clifton D

    2014-02-01

    Modern radiotherapy requires accurate region of interest (ROI) inputs for plan optimization and delivery. Target delineation, however, remains operator-dependent and potentially serves as a major source of treatment delivery error. In order to optimize this critical, yet observer-driven process, a flexible web-based platform for individual and cooperative target delineation analysis and instruction was developed in order to meet the following unmet needs: (1) an open-source/open-access platform for automated/semiautomated quantitative interobserver and intraobserver ROI analysis and comparison, (2) a real-time interface for radiation oncology trainee online self-education in ROI definition, and (3) a source for pilot data to develop and validate quality metrics for institutional and cooperative group quality assurance efforts. The resultant software, Target Contour Testing/Instructional Computer Software (TaCTICS), developed using Ruby on Rails, has since been implemented and proven flexible, feasible, and useful in several distinct analytical and research applications.

  5. Multi-version software reliability through fault-avoidance and fault-tolerance

    NASA Technical Reports Server (NTRS)

    Vouk, Mladen A.; Mcallister, David F.

    1989-01-01

    A number of experimental and theoretical issues associated with the practical use of multi-version software to provide run-time tolerance to software faults were investigated. A specialized tool was developed and evaluated for measuring testing coverage for a variety of metrics. The tool was used to collect information on the relationships between software faults and coverage provided by the testing process as measured by different metrics (including data flow metrics). Considerable correlation was found between coverage provided by some higher metrics and the elimination of faults in the code. Back-to-back testing was continued as an efficient mechanism for removal of un-correlated faults, and common-cause faults of variable span. Software reliability estimation methods was also continued based on non-random sampling, and the relationship between software reliability and code coverage provided through testing. New fault tolerance models were formulated. Simulation studies of the Acceptance Voting and Multi-stage Voting algorithms were finished and it was found that these two schemes for software fault tolerance are superior in many respects to some commonly used schemes. Particularly encouraging are the safety properties of the Acceptance testing scheme.

  6. Top 10 metrics for life science software good practices.

    PubMed

    Artaza, Haydee; Chue Hong, Neil; Corpas, Manuel; Corpuz, Angel; Hooft, Rob; Jimenez, Rafael C; Leskošek, Brane; Olivier, Brett G; Stourac, Jan; Svobodová Vařeková, Radka; Van Parys, Thomas; Vaughan, Daniel

    2016-01-01

    Metrics for assessing adoption of good development practices are a useful way to ensure that software is sustainable, reusable and functional. Sustainability means that the software used today will be available - and continue to be improved and supported - in the future. We report here an initial set of metrics that measure good practices in software development. This initiative differs from previously developed efforts in being a community-driven grassroots approach where experts from different organisations propose good software practices that have reasonable potential to be adopted by the communities they represent. We not only focus our efforts on understanding and prioritising good practices, we assess their feasibility for implementation and publish them here.

  7. Top 10 metrics for life science software good practices

    PubMed Central

    2016-01-01

    Metrics for assessing adoption of good development practices are a useful way to ensure that software is sustainable, reusable and functional. Sustainability means that the software used today will be available - and continue to be improved and supported - in the future. We report here an initial set of metrics that measure good practices in software development. This initiative differs from previously developed efforts in being a community-driven grassroots approach where experts from different organisations propose good software practices that have reasonable potential to be adopted by the communities they represent. We not only focus our efforts on understanding and prioritising good practices, we assess their feasibility for implementation and publish them here. PMID:27635232

  8. The maturing of the quality improvement paradigm in the SEL

    NASA Technical Reports Server (NTRS)

    Basili, Victor R.

    1993-01-01

    The Software Engineering Laboratory uses a paradigm for improving the software process and product, called the quality improvement paradigm. This paradigm has evolved over the past 18 years, along with our software development processes and product. Since 1976, when we first began the SEL, we have learned a great deal about improving the software process and product, making a great many mistakes along the way. Quality improvement paradigm, as it is currently defined, can be broken up into six steps: characterize the current project and its environment with respect to the appropriate models and metrics; set the quantifiable goals for successful project performance and improvement; choose the appropriate process model and supporting methods and tools for this project; execute the processes, construct the products, and collect, validate, and analyze the data to provide real-time feedback for corrective action; analyze the data to evaluate the current practices, determine problems, record findings, and make recommendations for future project improvements; and package the experience gained in the form of updated and refined models and other forms of structured knowledge gained from this and prior projects and save it in an experience base to be reused on future projects.

  9. Object-oriented productivity metrics

    NASA Technical Reports Server (NTRS)

    Connell, John L.; Eller, Nancy

    1992-01-01

    Software productivity metrics are useful for sizing and costing proposed software and for measuring development productivity. Estimating and measuring source lines of code (SLOC) has proven to be a bad idea because it encourages writing more lines of code and using lower level languages. Function Point Analysis is an improved software metric system, but it is not compatible with newer rapid prototyping and object-oriented approaches to software development. A process is presented here for counting object-oriented effort points, based on a preliminary object-oriented analysis. It is proposed that this approach is compatible with object-oriented analysis, design, programming, and rapid prototyping. Statistics gathered on actual projects are presented to validate the approach.

  10. The Applicability of Proposed Object-Oriented Metrics to Developer Feedback in Time to Impact Development

    NASA Technical Reports Server (NTRS)

    Neal, Ralph D.

    1996-01-01

    This paper looks closely at each of the software metrics generated by the McCabe object-Oriented Tool(TM) and its ability to convey timely information to developers. The metrics are examined for meaningfulness in terms of the scale assignable to the metric by the rules of measurement theory and the software dimension being measured. Recommendations are made as to the proper use of each metric and its ability to influence development at an early stage. The metrics of the McCabe Object-Oriented Tool(TM) set were selected because of the tool's use in a couple of NASA IV&V projects.

  11. Automated support for experience-based software management

    NASA Technical Reports Server (NTRS)

    Valett, Jon D.

    1992-01-01

    To effectively manage a software development project, the software manager must have access to key information concerning a project's status. This information includes not only data relating to the project of interest, but also, the experience of past development efforts within the environment. This paper describes the concepts and functionality of a software management tool designed to provide this information. This tool, called the Software Management Environment (SME), enables the software manager to compare an ongoing development effort with previous efforts and with models of the 'typical' project within the environment, to predict future project status, to analyze a project's strengths and weaknesses, and to assess the project's quality. In order to provide these functions the tool utilizes a vast corporate memory that includes a data base of software metrics, a set of models and relationships that describe the software development environment, and a set of rules that capture other knowledge and experience of software managers within the environment. Integrating these major concepts into one software management tool, the SME is a model of the type of management tool needed for all software development organizations.

  12. Experimental evaluation of ontology-based HIV/AIDS frequently asked question retrieval system.

    PubMed

    Ayalew, Yirsaw; Moeng, Barbara; Mosweunyane, Gontlafetse

    2018-05-01

    This study presents the results of experimental evaluations of an ontology-based frequently asked question retrieval system in the domain of HIV and AIDS. The main purpose of the system is to provide answers to questions on HIV/AIDS using ontology. To evaluate the effectiveness of the frequently asked question retrieval system, we conducted two experiments. The first experiment focused on the evaluation of the quality of the ontology we developed using the OQuaRE evaluation framework which is based on software quality metrics and metrics designed for ontology quality evaluation. The second experiment focused on evaluating the effectiveness of the ontology in retrieving relevant answers. For this we used an open-source information retrieval platform, Terrier, with retrieval models BM25 and PL2. For the measurement of performance, we used the measures mean average precision, mean reciprocal rank, and precision at 5. The results suggest that frequently asked question retrieval with ontology is more effective than frequently asked question retrieval without ontology in the domain of HIV/AIDS.

  13. Implementation of statistical process control for proteomic experiments via LC MS/MS.

    PubMed

    Bereman, Michael S; Johnson, Richard; Bollinger, James; Boss, Yuval; Shulman, Nick; MacLean, Brendan; Hoofnagle, Andrew N; MacCoss, Michael J

    2014-04-01

    Statistical process control (SPC) is a robust set of tools that aids in the visualization, detection, and identification of assignable causes of variation in any process that creates products, services, or information. A tool has been developed termed Statistical Process Control in Proteomics (SProCoP) which implements aspects of SPC (e.g., control charts and Pareto analysis) into the Skyline proteomics software. It monitors five quality control metrics in a shotgun or targeted proteomic workflow. None of these metrics require peptide identification. The source code, written in the R statistical language, runs directly from the Skyline interface, which supports the use of raw data files from several of the mass spectrometry vendors. It provides real time evaluation of the chromatographic performance (e.g., retention time reproducibility, peak asymmetry, and resolution), and mass spectrometric performance (targeted peptide ion intensity and mass measurement accuracy for high resolving power instruments) via control charts. Thresholds are experiment- and instrument-specific and are determined empirically from user-defined quality control standards that enable the separation of random noise and systematic error. Finally, Pareto analysis provides a summary of performance metrics and guides the user to metrics with high variance. The utility of these charts to evaluate proteomic experiments is illustrated in two case studies.

  14. GRC GSFC TDRSS Waveform Metrics Report

    NASA Technical Reports Server (NTRS)

    Mortensen, Dale J.

    2013-01-01

    The report presents software metrics and porting metrics for the GGT Waveform. The porting was from a ground-based COTS SDR, the SDR-3000, to the CoNNeCT JPL SDR. The report does not address any of the Operating Environment (OE) software development, nor the original TDRSS waveform development at GSFC for the COTS SDR. With regard to STRS, the report presents compliance data and lessons learned.

  15. Evaluating Process Sustainability Using Flowsheet Monitoring

    EPA Science Inventory

    Environmental metric software can be used to evaluate the sustainability of a chemical based on data from the chemical process that is used to manufacture it. One problem in developing environmental metric software is that chemical process simulation packages typically do not rea...

  16. Evaluating Process Sustainability Using Flowsheet Monitoring (Abstract)

    EPA Science Inventory

    Environmental metric software can be used to evaluate the sustainability of a chemical based upon data from the chemical process that is used to manufacture it. One problem in developing environmental metric software is that chemical process simulation packages typically do not p...

  17. Aquatic Acoustic Metrics Interface

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2012-12-18

    Fishes and marine mammals may suffer a range of potential effects from exposure to intense underwater sound generated by anthropogenic activities such as pile driving, shipping, sonars, and underwater blasting. Several underwater sound recording (USR) devices have been built to acquire samples of the underwater sound generated by anthropogenic activities. Software becomes indispensable for processing and analyzing the audio files recorded by these USRs. The new Aquatic Acoustic Metrics Interface Utility Software (AAMI) is specifically designed for analysis of underwater sound recordings to provide data in metrics that facilitate evaluation of the potential impacts of the sound on aquatic animals.more » In addition to the basic functions, such as loading and editing audio files recorded by USRs and batch processing of sound files, the software utilizes recording system calibration data to compute important parameters in physical units. The software also facilitates comparison of the noise sound sample metrics with biological measures such as audiograms of the sensitivity of aquatic animals to the sound, integrating various components into a single analytical frame.« less

  18. Comprehensive Quantitative Analysis on Privacy Leak Behavior

    PubMed Central

    Fan, Lejun; Wang, Yuanzhuo; Jin, Xiaolong; Li, Jingyuan; Cheng, Xueqi; Jin, Shuyuan

    2013-01-01

    Privacy information is prone to be leaked by illegal software providers with various motivations. Privacy leak behavior has thus become an important research issue of cyber security. However, existing approaches can only qualitatively analyze privacy leak behavior of software applications. No quantitative approach, to the best of our knowledge, has been developed in the open literature. To fill this gap, in this paper we propose for the first time four quantitative metrics, namely, possibility, severity, crypticity, and manipulability, for privacy leak behavior analysis based on Privacy Petri Net (PPN). In order to compare the privacy leak behavior among different software, we further propose a comprehensive metric, namely, overall leak degree, based on these four metrics. Finally, we validate the effectiveness of the proposed approach using real-world software applications. The experimental results demonstrate that our approach can quantitatively analyze the privacy leak behaviors of various software types and reveal their characteristics from different aspects. PMID:24066046

  19. Comprehensive quantitative analysis on privacy leak behavior.

    PubMed

    Fan, Lejun; Wang, Yuanzhuo; Jin, Xiaolong; Li, Jingyuan; Cheng, Xueqi; Jin, Shuyuan

    2013-01-01

    Privacy information is prone to be leaked by illegal software providers with various motivations. Privacy leak behavior has thus become an important research issue of cyber security. However, existing approaches can only qualitatively analyze privacy leak behavior of software applications. No quantitative approach, to the best of our knowledge, has been developed in the open literature. To fill this gap, in this paper we propose for the first time four quantitative metrics, namely, possibility, severity, crypticity, and manipulability, for privacy leak behavior analysis based on Privacy Petri Net (PPN). In order to compare the privacy leak behavior among different software, we further propose a comprehensive metric, namely, overall leak degree, based on these four metrics. Finally, we validate the effectiveness of the proposed approach using real-world software applications. The experimental results demonstrate that our approach can quantitatively analyze the privacy leak behaviors of various software types and reveal their characteristics from different aspects.

  20. Quality measurement for rhinosinusitis: a review from the Quality Improvement Committee of the American Rhinologic Society.

    PubMed

    Rudmik, Luke; Mattos, Jose; Schneider, John; Manes, Peter R; Stokken, Janalee K; Lee, Jivianne; Higgins, Thomas S; Schlosser, Rodney J; Reh, Douglas D; Setzen, Michael; Soler, Zachary M

    2017-09-01

    Measuring quality outcomes is an important prerequisite to improve quality of care. Rhinosinusitis represents a high value target to improve quality of care because it has a high prevalence of disease, large economic burden, and large practice variation. In this study we review the current state of quality measurement for management of both acute (ARS) and chronic rhinosinusitis (CRS). The major national quality metric repositories and clearinghouses were queried. Additional searches included the American Academy of Otolaryngology-Head and Neck Surgery database, PubMed, and Google to attempt to capture any additional quality metrics. Seven quality metrics for ARS and 4 quality metrics for CRS were identified. ARS metrics focused on appropriateness of diagnosis (n = 1), antibiotic prescribing (n = 4), and radiologic imaging (n = 2). CRS quality metrics focused on appropriateness of diagnosis (n = 1), radiologic imaging (n = 1), and measurement of patient quality of life (n = 2). The Physician Quality Reporting System (PQRS) currently tracks 3 ARS quality metrics and 1 CRS quality metric. There are no outcome-based rhinosinusitis quality metrics and no metrics that assess domains of safety, patient-centeredness, and timeliness of care. The current status of quality measurement for rhinosinusitis has focused primarily on the quality domain of efficiency and process measures for ARS. More work is needed to develop, validate, and track outcome-based quality metrics along with CRS-specific metrics. Although there has been excellent work done to improve quality measurement for rhinosinusitis, there remain major gaps and challenges that need to be considered during the development of future metrics. © 2017 ARS-AAOA, LLC.

  1. Automatic documentation system extension to multi-manufacturers' computers and to measure, improve, and predict software reliability

    NASA Technical Reports Server (NTRS)

    Simmons, D. B.

    1975-01-01

    The DOMONIC system has been modified to run on the Univac 1108 and the CDC 6600 as well as the IBM 370 computer system. The DOMONIC monitor system has been implemented to gather data which can be used to optimize the DOMONIC system and to predict the reliability of software developed using DOMONIC. The areas of quality metrics, error characterization, program complexity, program testing, validation and verification are analyzed. A software reliability model for estimating program completion levels and one on which to base system acceptance have been developed. The DAVE system which performs flow analysis and error detection has been converted from the University of Colorado CDC 6400/6600 computer to the IBM 360/370 computer system for use with the DOMONIC system.

  2. SU-E-T-76: A Software System to Monitor VMAT Plan Complexity in a Large Radiotherapy Centre

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arumugam, S; Xing, A; Ingham Institute, Sydney, NSW

    2015-06-15

    Purpose: To develop a system that analyses and reports the complexity of Volumetric Modulated Arc Therapy (VMAT) plans to aid in the decision making for streamlining patient specific dosimetric quality assurance (QA) tests. Methods: A software system, Delcheck, was developed in-house to calculate VMAT plan and delivery complexity using the treatment delivery file. Delcheck has the functionality to calculate multiple plan complexity metrics including the Li-Xing Modulation Index (LI-MI), multiplicative combination of Leaf Travel and Modulation Complexity Score (LTMCSv), Monitor Units per prescribed dose (MU/D) and the delivery complexity index (MIt) that incorporates the modulation of dose rate, leaf speedmore » and gantry speed. Delcheck includes database functionality to store and compare plan metrics for a specified treatment site. The overall plan and delivery complexity is assessed based on the 95% conformance limit of the complexity metrics as Similar, More or Less complex. The functionality of the software was tested using 42 prostate conventional, 10 prostate SBRT and 15 prostate bed VMAT plans generated for an Elekta linear accelerator. Results: The mean(σ) of LI-MI for conventional, SBRT and prostate bed plans were 1690(486), 3215.4(1294) and 3258(982) respectively. The LTMCSv of the studied categories were 0.334(0.05), 0.325(0.07) and 0.3112(0.09). The MU/D of the studied categories were 2.4(0.4), 2.7(0.7) and 2.5(0.5). The MIt of the studied categories were 21.6(3.4), 18.2(3.0) and 35.9(6.6). The values of the complexity metrics show that LI-MI appeared to resolve the plan complexity better than LTMCSv and MU/D. The MIt value increased as the delivery complexity increased. Conclusion: The developed software was shown to be working as expected. In studied treatment categories Prostate bed plans are more complex in both plan and delivery and SBRT is more complex in plan and less complex in delivery as demonstrated by LI-MI and MIt. This project was funded through a Cancer Council NSW Project Grant (RG14-11)« less

  3. Coverage Metrics for Model Checking

    NASA Technical Reports Server (NTRS)

    Penix, John; Visser, Willem; Norvig, Peter (Technical Monitor)

    2001-01-01

    When using model checking to verify programs in practice, it is not usually possible to achieve complete coverage of the system. In this position paper we describe ongoing research within the Automated Software Engineering group at NASA Ames on the use of test coverage metrics to measure partial coverage and provide heuristic guidance for program model checking. We are specifically interested in applying and developing coverage metrics for concurrent programs that might be used to support certification of next generation avionics software.

  4. Aquatic Acoustic Metrics Interface Utility for Underwater Sound Monitoring and Analysis

    PubMed Central

    Ren, Huiying; Halvorsen, Michele B.; Deng, Zhiqun Daniel; Carlson, Thomas J.

    2012-01-01

    Fishes and marine mammals may suffer a range of potential effects from exposure to intense underwater sound generated by anthropogenic activities such as pile driving, shipping, sonars, and underwater blasting. Several underwater sound recording (USR) devices have been built to acquire samples of the underwater sound generated by anthropogenic activities. Software becomes indispensable for processing and analyzing the audio files recorded by these USRs. In this paper, we provide a detailed description of a new software package, the Aquatic Acoustic Metrics Interface (AAMI), specifically designed for analysis of underwater sound recordings to provide data in metrics that facilitate evaluation of the potential impacts of the sound on aquatic animals. In addition to the basic functions, such as loading and editing audio files recorded by USRs and batch processing of sound files, the software utilizes recording system calibration data to compute important parameters in physical units. The software also facilitates comparison of the noise sound sample metrics with biological measures such as audiograms of the sensitivity of aquatic animals to the sound, integrating various components into a single analytical frame. The features of the AAMI software are discussed, and several case studies are presented to illustrate its functionality. PMID:22969353

  5. Comparing de novo genome assembly: the long and short of it.

    PubMed

    Narzisi, Giuseppe; Mishra, Bud

    2011-04-29

    Recent advances in DNA sequencing technology and their focal role in Genome Wide Association Studies (GWAS) have rekindled a growing interest in the whole-genome sequence assembly (WGSA) problem, thereby, inundating the field with a plethora of new formalizations, algorithms, heuristics and implementations. And yet, scant attention has been paid to comparative assessments of these assemblers' quality and accuracy. No commonly accepted and standardized method for comparison exists yet. Even worse, widely used metrics to compare the assembled sequences emphasize only size, poorly capturing the contig quality and accuracy. This paper addresses these concerns: it highlights common anomalies in assembly accuracy through a rigorous study of several assemblers, compared under both standard metrics (N50, coverage, contig sizes, etc.) as well as a more comprehensive metric (Feature-Response Curves, FRC) that is introduced here; FRC transparently captures the trade-offs between contigs' quality against their sizes. For this purpose, most of the publicly available major sequence assemblers--both for low-coverage long (Sanger) and high-coverage short (Illumina) reads technologies--are compared. These assemblers are applied to microbial (Escherichia coli, Brucella, Wolbachia, Staphylococcus, Helicobacter) and partial human genome sequences (Chr. Y), using sequence reads of various read-lengths, coverages, accuracies, and with and without mate-pairs. It is hoped that, based on these evaluations, computational biologists will identify innovative sequence assembly paradigms, bioinformaticists will determine promising approaches for developing "next-generation" assemblers, and biotechnologists will formulate more meaningful design desiderata for sequencing technology platforms. A new software tool for computing the FRC metric has been developed and is available through the AMOS open-source consortium.

  6. The use of the general image quality equation in the design and evaluation of imaging systems

    NASA Astrophysics Data System (ADS)

    Cota, Steve A.; Florio, Christopher J.; Duvall, David J.; Leon, Michael A.

    2009-08-01

    The design of any modern imaging system is the end result of many trade studies, each seeking to optimize image quality within real world constraints such as cost, schedule and overall risk. The National Imagery Interpretability Rating Scale (NIIRS) is a useful measure of image quality, because, by characterizing the overall interpretability of an image, it combines into one metric those contributors to image quality to which a human interpreter is most sensitive. The main drawback to using a NIIRS rating as a measure of image quality in engineering trade studies is the fact that it is tied to the human observer and cannot be predicted from physical principles and engineering parameters alone. The General Image Quality Equation (GIQE) of Leachtenauer et al. 1997 [Appl. Opt. 36, 8322-8328 (1997)] is a regression of actual image analyst NIIRS ratings vs. readily calculable engineering metrics, and provides a mechanism for using the expected NIIRS rating of an imaging system in the design and evaluation process. In this paper, we will discuss how we use the GIQE in conjunction with The Aerospace Corporation's Parameterized Image Chain Analysis & Simulation SOftware (PICASSO) to evaluate imager designs, taking a hypothetical high resolution commercial imaging system as an example.

  7. StatsDB: platform-agnostic storage and understanding of next generation sequencing run metrics

    PubMed Central

    Ramirez-Gonzalez, Ricardo H.; Leggett, Richard M.; Waite, Darren; Thanki, Anil; Drou, Nizar; Caccamo, Mario; Davey, Robert

    2014-01-01

    Modern sequencing platforms generate enormous quantities of data in ever-decreasing amounts of time. Additionally, techniques such as multiplex sequencing allow one run to contain hundreds of different samples. With such data comes a significant challenge to understand its quality and to understand how the quality and yield are changing across instruments and over time. As well as the desire to understand historical data, sequencing centres often have a duty to provide clear summaries of individual run performance to collaborators or customers. We present StatsDB, an open-source software package for storage and analysis of next generation sequencing run metrics. The system has been designed for incorporation into a primary analysis pipeline, either at the programmatic level or via integration into existing user interfaces. Statistics are stored in an SQL database and APIs provide the ability to store and access the data while abstracting the underlying database design. This abstraction allows simpler, wider querying across multiple fields than is possible by the manual steps and calculation required to dissect individual reports, e.g. ”provide metrics about nucleotide bias in libraries using adaptor barcode X, across all runs on sequencer A, within the last month”. The software is supplied with modules for storage of statistics from FastQC, a commonly used tool for analysis of sequence reads, but the open nature of the database schema means it can be easily adapted to other tools. Currently at The Genome Analysis Centre (TGAC), reports are accessed through our LIMS system or through a standalone GUI tool, but the API and supplied examples make it easy to develop custom reports and to interface with other packages. PMID:24627795

  8. NGSCheckMate: software for validating sample identity in next-generation sequencing studies within and across data types.

    PubMed

    Lee, Sejoon; Lee, Soohyun; Ouellette, Scott; Park, Woong-Yang; Lee, Eunjung A; Park, Peter J

    2017-06-20

    In many next-generation sequencing (NGS) studies, multiple samples or data types are profiled for each individual. An important quality control (QC) step in these studies is to ensure that datasets from the same subject are properly paired. Given the heterogeneity of data types, file types and sequencing depths in a multi-dimensional study, a robust program that provides a standardized metric for genotype comparisons would be useful. Here, we describe NGSCheckMate, a user-friendly software package for verifying sample identities from FASTQ, BAM or VCF files. This tool uses a model-based method to compare allele read fractions at known single-nucleotide polymorphisms, considering depth-dependent behavior of similarity metrics for identical and unrelated samples. Our evaluation shows that NGSCheckMate is effective for a variety of data types, including exome sequencing, whole-genome sequencing, RNA-seq, ChIP-seq, targeted sequencing and single-cell whole-genome sequencing, with a minimal requirement for sequencing depth (>0.5X). An alignment-free module can be run directly on FASTQ files for a quick initial check. We recommend using this software as a QC step in NGS studies. https://github.com/parklab/NGSCheckMate. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  9. Software development predictors, error analysis, reliability models and software metric analysis

    NASA Technical Reports Server (NTRS)

    Basili, Victor

    1983-01-01

    The use of dynamic characteristics as predictors for software development was studied. It was found that there are some significant factors that could be useful as predictors. From a study on software errors and complexity, it was shown that meaningful results can be obtained which allow insight into software traits and the environment in which it is developed. Reliability models were studied. The research included the field of program testing because the validity of some reliability models depends on the answers to some unanswered questions about testing. In studying software metrics, data collected from seven software engineering laboratory (FORTRAN) projects were examined and three effort reporting accuracy checks were applied to demonstrate the need to validate a data base. Results are discussed.

  10. BatMass: a Java Software Platform for LC-MS Data Visualization in Proteomics and Metabolomics.

    PubMed

    Avtonomov, Dmitry M; Raskind, Alexander; Nesvizhskii, Alexey I

    2016-08-05

    Mass spectrometry (MS) coupled to liquid chromatography (LC) is a commonly used technique in metabolomic and proteomic research. As the size and complexity of LC-MS-based experiments grow, it becomes increasingly more difficult to perform quality control of both raw data and processing results. In a practical setting, quality control steps for raw LC-MS data are often overlooked, and assessment of an experiment's success is based on some derived metrics such as "the number of identified compounds". The human brain interprets visual data much better than plain text, hence the saying "a picture is worth a thousand words". Here, we present the BatMass software package, which allows for performing quick quality control of raw LC-MS data through its fast visualization capabilities. It also serves as a testbed for developers of LC-MS data processing algorithms by providing a data access library for open mass spectrometry file formats and a means of visually mapping processing results back to the original data. We illustrate the utility of BatMass with several use cases of quality control and data exploration.

  11. BatMass: a Java software platform for LC/MS data visualization in proteomics and metabolomics

    PubMed Central

    Avtonomov, Dmitry; Raskind, Alexander; Nesvizhskii, Alexey I.

    2017-01-01

    Mass spectrometry (MS) coupled to liquid chromatography (LC) is a commonly used technique in metabolomic and proteomic research. As the size and complexity of LC/MS based experiments grow, it becomes increasingly more difficult to perform quality control of both raw data and processing results. In a practical setting, quality control steps for raw LC/MS data are often overlooked and assessment of an experiment's success is based on some derived metrics such as “the number of identified compounds”. Human brain interprets visual data much better than plain text, hence the saying “a picture is worth a thousand words”. Here we present BatMass software package which allows to perform quick quality control of raw LC/MS data through its fast visualization capabilities. It also serves as a testbed for developers of LC/MS data processing algorithms by providing a data access library for open mass spectrometry file formats and a means of visually mapping processing results back to the original data. We illustrate the utility of BatMass with several use cases of quality control and data exploration. PMID:27306858

  12. FQC Dashboard: integrates FastQC results into a web-based, interactive, and extensible FASTQ quality control tool.

    PubMed

    Brown, Joseph; Pirrung, Meg; McCue, Lee Ann

    2017-06-09

    FQC is software that facilitates quality control of FASTQ files by carrying out a QC protocol using FastQC, parsing results, and aggregating quality metrics into an interactive dashboard designed to richly summarize individual sequencing runs. The dashboard groups samples in dropdowns for navigation among the data sets, utilizes human-readable configuration files to manipulate the pages and tabs, and is extensible with CSV data. FQC is implemented in Python 3 and Javascript, and is maintained under an MIT license. Documentation and source code is available at: https://github.com/pnnl/fqc . joseph.brown@pnnl.gov. © The Author(s) 2017. Published by Oxford University Press.

  13. Benchmarking heart rate variability toolboxes.

    PubMed

    Vest, Adriana N; Li, Qiao; Liu, Chengyu; Nemati, Shamim; Shah, Amit; Clifford, Gari D

    Heart rate variability (HRV) metrics hold promise as potential indicators for autonomic function, prediction of adverse cardiovascular outcomes, psychophysiological status, and general wellness. Although the investigation of HRV has been prevalent for several decades, the methods used for preprocessing, windowing, and choosing appropriate parameters lack consensus among academic and clinical investigators. A comprehensive and open-source modular program is presented for calculating HRV implemented in Matlab with evidence-based algorithms and output formats. We compare our software with another widely used HRV toolbox written in C and available through PhysioNet.org. Our findings show substantially similar results when using high quality electrocardiograms (ECG) free from arrhythmias. Our software shows equivalent performance alongside an established predecessor and includes validated tools for performing preprocessing, signal quality, and arrhythmia detection to help provide standardization and repeatability in the field, leading to fewer errors in the presence of noise or arrhythmias. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. On the Use of Software Metrics as a Predictor of Software Security Problems

    DTIC Science & Technology

    2013-01-01

    models to determine if additional metrics are required to increase the accuracy of the model: non-security SCSA warnings, code churn and size, the...vulnerabilities reported by testing and those found in the field. Summary of Most Important Results We evaluated our model on three commercial telecommunications

  15. Quality Metrics in Neonatal and Pediatric Critical Care Transport: A National Delphi Project.

    PubMed

    Schwartz, Hamilton P; Bigham, Michael T; Schoettker, Pamela J; Meyer, Keith; Trautman, Michael S; Insoft, Robert M

    2015-10-01

    The transport of neonatal and pediatric patients to tertiary care facilities for specialized care demands monitoring the quality of care delivered during transport and its impact on patient outcomes. In 2011, pediatric transport teams in Ohio met to identify quality indicators permitting comparisons among programs. However, no set of national consensus quality metrics exists for benchmarking transport teams. The aim of this project was to achieve national consensus on appropriate neonatal and pediatric transport quality metrics. Modified Delphi technique. The first round of consensus determination was via electronic mail survey, followed by rounds of consensus determination in-person at the American Academy of Pediatrics Section on Transport Medicine's 2012 Quality Metrics Summit. All attendees of the American Academy of Pediatrics Section on Transport Medicine Quality Metrics Summit, conducted on October 21-23, 2012, in New Orleans, LA, were eligible to participate. Candidate quality metrics were identified through literature review and those metrics currently tracked by participating programs. Participants were asked in a series of rounds to identify "very important" quality metrics for transport. It was determined a priori that consensus on a metric's importance was achieved when at least 70% of respondents were in agreement. This is consistent with other Delphi studies. Eighty-two candidate metrics were considered initially. Ultimately, 12 metrics achieved consensus as "very important" to transport. These include metrics related to airway management, team mobilization time, patient and crew injuries, and adverse patient care events. Definitions were assigned to the 12 metrics to facilitate uniform data tracking among programs. The authors succeeded in achieving consensus among a diverse group of national transport experts on 12 core neonatal and pediatric transport quality metrics. We propose that transport teams across the country use these metrics to benchmark and guide their quality improvement activities.

  16. TREHS: An open-access software tool for investigating and evaluating temporary river regimes as a first step for their ecological status assessment.

    PubMed

    Gallart, Francesc; Cid, Núria; Latron, Jérôme; Llorens, Pilar; Bonada, Núria; Jeuffroy, Justin; Jiménez-Argudo, Sara-María; Vega, Rosa-María; Solà, Carolina; Soria, Maria; Bardina, Mònica; Hernández-Casahuga, Antoni-Josep; Fidalgo, Aránzazu; Estrela, Teodoro; Munné, Antoni; Prat, Narcís

    2017-12-31

    When the regime of a river is not perennial, there are four main difficulties with the use of hydrographs for assessing hydrological alteration: i) the main hydrological features relevant for biological communities are not quantitative (discharges) but qualitative (phases such as flowing water, stagnant pools or lack of surface water), ii) stream flow records do not inform on the temporal occurrence of stagnant pools, iii) as most of the temporary streams are ungauged, their regime has to be evaluated by alternative methods such as remote sensing or citizen science, and iv) the biological quality assessment of the ecological status of a temporary stream must follow a sampling schedule and references adapted to the flow- pool-dry regime. To overcome these challenges within an operational approach, the freely available software tool TREHS has been developed within the EU LIFE TRIVERS project. This software permits the input of information from flow simulations obtained with any rainfall-runoff model (to set an unimpacted reference stream regime) and compares this with the information obtained from flow gauging records (if available) and interviews with local people, as well as instantaneous observations by individuals and interpretation of ground-level or aerial photographs. Up to six metrics defining the permanence of water flow, the presence of stagnant pools and their temporal patterns of occurrence are used to determine natural and observed river regimes and to assess the degree of hydrological alteration. A new regime classification specifically designed for temporary rivers was developed using the metrics that measure the relative permanence of the three main phases: flow, disconnected pools and dry stream bed. Finally, the software characterizes the differences between the natural and actual regimes, diagnoses the hydrological status (degree of hydrological alteration), assesses the significance and robustness of the diagnosis and recommends the best periods for biological quality samplings. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Software Engineering Education Directory

    DTIC Science & Technology

    1990-04-01

    and Engineering (CMSC 735) Codes: GPEV2 * Textiooks: IEEE Tutoria on Models and Metrics for Software Management and Engameeing by Basi, Victor R...Software Engineering (Comp 227) Codes: GPRY5 Textbooks: IEEE Tutoria on Software Design Techniques by Freeman, Peter and Wasserman, Anthony 1. Software

  18. PQScal (Power Quality Score Calculation for Distribution Systems with DER Integration)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Power Quality is of great importance to evaluate the “health” of a distribution system, especially when the distributed energy resource (DER) penetration becomes more significant. The individual components that make up power quality, such as voltage magnitude and unbalance, can be measured in simulations or in the field, however, a comprehensive method to incorporate all of these values into a single score doesn't exist. As a result, we propose a methodology to quantify the power quality health using the single number value, named as Power Quality Score (PQS). The PQS is dependent on six metrics that are developed based onmore » both components that directly impact power quality and those are often reference in the context of power quality. These six metrics are named as System Average Voltage Magnitude Violation Index (SAVMVI), System Average Voltage Fluctuation Index (SAVFI), System Average Voltage Unbalance Index (SAVUI), System Control Device Operation Index (SCDOI), System Reactive Power Demand Index (SRPDI) and System Energy Loss Index (SELI). This software tool, PQScal, is developed based on this novel PQS methodology. Besides of traditional distribution systems, PQScal can also measure the power quality for distribution systems with various DER penetrations. PQScal has been tested on two utility distribution feeders with distinct model characteristics and its effectiveness has been proved. In sum, PQScal can help utilities or other parties to measure the power quality of distribution systems with DER integration easily and effectively.« less

  19. SU-F-T-231: Improving the Efficiency of a Radiotherapy Peer-Review System for Quality Assurance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hsu, S; Basavatia, A; Garg, M

    Purpose: To improve the efficiency of a radiotherapy peer-review system using a commercially available software application for plan quality evaluation and documentation. Methods: A commercial application, FullAccess (Radialogica LLC, Version 1.4.4), was implemented in a Citrix platform for peer-review process and patient documentation. This application can display images, isodose lines, and dose-volume histograms and create plan reports for peer-review process. Dose metrics in the report can also be benchmarked for plan quality evaluation. Site-specific templates were generated based on departmental treatment planning policies and procedures for each disease site, which generally follow RTOG protocols as well as published prospective clinicalmore » trial data, including both conventional fractionation and hypo-fractionation schema. Once a plan is ready for review, the planner exports the plan to FullAccess, applies the site-specific template, and presents the report for plan review. The plan is still reviewed in the treatment planning system, as that is the legal record. Upon physician’s approval of a plan, the plan is packaged for peer review with the plan report and dose metrics are saved to the database. Results: The reports show dose metrics of PTVs and critical organs for the plans and also indicate whether or not the metrics are within tolerance. Graphical results with green, yellow, and red lights are displayed of whether planning objectives have been met. In addition, benchmarking statistics are collected to see where the current plan falls compared to all historical plans on each metric. All physicians in peer review can easily verify constraints by these reports. Conclusion: We have demonstrated the improvement in a radiotherapy peer-review system, which allows physicians to easily verify planning constraints for different disease sites and fractionation schema, allows for standardization in the clinic to ensure that departmental policies are maintained, and builds a comprehensive database for potential clinical outcome evaluation.« less

  20. Enhancing reproducibility in scientific computing: Metrics and registry for Singularity containers.

    PubMed

    Sochat, Vanessa V; Prybol, Cameron J; Kurtzer, Gregory M

    2017-01-01

    Here we present Singularity Hub, a framework to build and deploy Singularity containers for mobility of compute, and the singularity-python software with novel metrics for assessing reproducibility of such containers. Singularity containers make it possible for scientists and developers to package reproducible software, and Singularity Hub adds automation to this workflow by building, capturing metadata for, visualizing, and serving containers programmatically. Our novel metrics, based on custom filters of content hashes of container contents, allow for comparison of an entire container, including operating system, custom software, and metadata. First we will review Singularity Hub's primary use cases and how the infrastructure has been designed to support modern, common workflows. Next, we conduct three analyses to demonstrate build consistency, reproducibility metric and performance and interpretability, and potential for discovery. This is the first effort to demonstrate a rigorous assessment of measurable similarity between containers and operating systems. We provide these capabilities within Singularity Hub, as well as the source software singularity-python that provides the underlying functionality. Singularity Hub is available at https://singularity-hub.org, and we are excited to provide it as an openly available platform for building, and deploying scientific containers.

  1. Enhancing reproducibility in scientific computing: Metrics and registry for Singularity containers

    PubMed Central

    Prybol, Cameron J.; Kurtzer, Gregory M.

    2017-01-01

    Here we present Singularity Hub, a framework to build and deploy Singularity containers for mobility of compute, and the singularity-python software with novel metrics for assessing reproducibility of such containers. Singularity containers make it possible for scientists and developers to package reproducible software, and Singularity Hub adds automation to this workflow by building, capturing metadata for, visualizing, and serving containers programmatically. Our novel metrics, based on custom filters of content hashes of container contents, allow for comparison of an entire container, including operating system, custom software, and metadata. First we will review Singularity Hub’s primary use cases and how the infrastructure has been designed to support modern, common workflows. Next, we conduct three analyses to demonstrate build consistency, reproducibility metric and performance and interpretability, and potential for discovery. This is the first effort to demonstrate a rigorous assessment of measurable similarity between containers and operating systems. We provide these capabilities within Singularity Hub, as well as the source software singularity-python that provides the underlying functionality. Singularity Hub is available at https://singularity-hub.org, and we are excited to provide it as an openly available platform for building, and deploying scientific containers. PMID:29186161

  2. Software Process Assessment (SPA)

    NASA Technical Reports Server (NTRS)

    Rosenberg, Linda H.; Sheppard, Sylvia B.; Butler, Scott A.

    1994-01-01

    NASA's environment mirrors the changes taking place in the nation at large, i.e. workers are being asked to do more work with fewer resources. For software developers at NASA's Goddard Space Flight Center (GSFC), the effects of this change are that we must continue to produce quality code that is maintainable and reusable, but we must learn to produce it more efficiently and less expensively. To accomplish this goal, the Data Systems Technology Division (DSTD) at GSFC is trying a variety of both proven and state-of-the-art techniques for software development (e.g., object-oriented design, prototyping, designing for reuse, etc.). In order to evaluate the effectiveness of these techniques, the Software Process Assessment (SPA) program was initiated. SPA was begun under the assumption that the effects of different software development processes, techniques, and tools, on the resulting product must be evaluated in an objective manner in order to assess any benefits that may have accrued. SPA involves the collection and analysis of software product and process data. These data include metrics such as effort, code changes, size, complexity, and code readability. This paper describes the SPA data collection and analysis methodology and presents examples of benefits realized thus far by DSTD's software developers and managers.

  3. Feasibility of Turing-Style Tests for Autonomous Aerial Vehicle "Intelligence"

    NASA Technical Reports Server (NTRS)

    Young, Larry A.

    2007-01-01

    A new approach is suggested to define and evaluate key metrics as to autonomous aerial vehicle performance. This approach entails the conceptual definition of a "Turing Test" for UAVs. Such a "UAV Turing test" would be conducted by means of mission simulations and/or tailored flight demonstrations of vehicles under the guidance of their autonomous system software. These autonomous vehicle mission simulations and flight demonstrations would also have to be benchmarked against missions "flown" with pilots/human-operators in the loop. In turn, scoring criteria for such testing could be based upon both quantitative mission success metrics (unique to each mission) and by turning to analog "handling quality" metrics similar to the well-known Cooper-Harper pilot ratings used for manned aircraft. Autonomous aerial vehicles would be considered to have successfully passed this "UAV Turing Test" if the aggregate mission success metrics and handling qualities for the autonomous aerial vehicle matched or exceeded the equivalent metrics for missions conducted with pilots/human-operators in the loop. Alternatively, an independent, knowledgeable observer could provide the "UAV Turing Test" ratings of whether a vehicle is autonomous or "piloted." This observer ideally would, in the more sophisticated mission simulations, also have the enhanced capability of being able to override the scripted mission scenario and instigate failure modes and change of flight profile/plans. If a majority of mission tasks are rated as "piloted" by the observer, when in reality the vehicle/simulation is fully- or semi- autonomously controlled, then the vehicle/simulation "passes" the "UAV Turing Test." In this regards, this second "UAV Turing Test" approach is more consistent with Turing s original "imitation game" proposal. The overall feasibility, and important considerations and limitations, of such an approach for judging/evaluating autonomous aerial vehicle "intelligence" will be discussed from a theoretical perspective.

  4. An Aquatic Acoustic Metrics Interface Utility for Underwater Sound Monitoring and Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ren, Huiying; Halvorsen, Michele B.; Deng, Zhiqun

    Fishes and other marine mammals suffer a range of potential effects from intense sound sources generated by anthropogenic underwater processes such as pile driving, shipping, sonars, and underwater blasting. Several underwater sound recording devices (USR) were built to monitor the acoustic sound pressure waves generated by those anthropogenic underwater activities, so the relevant processing software becomes indispensable for analyzing the audio files recorded by these USRs. However, existing software packages did not meet performance and flexibility requirements. In this paper, we provide a detailed description of a new software package, named Aquatic Acoustic Metrics Interface (AAMI), which is a Graphicalmore » User Interface (GUI) designed for underwater sound monitoring and analysis. In addition to the general functions, such as loading and editing audio files recorded by USRs, the software can compute a series of acoustic metrics in physical units, monitor the sound's influence on fish hearing according to audiograms from different species of fishes and marine mammals, and batch process the sound files. The detailed applications of the software AAMI will be discussed along with several test case scenarios to illustrate its functionality.« less

  5. Cost-Sensitive Radial Basis Function Neural Network Classifier for Software Defect Prediction

    PubMed Central

    Venkatesan, R.

    2016-01-01

    Effective prediction of software modules, those that are prone to defects, will enable software developers to achieve efficient allocation of resources and to concentrate on quality assurance activities. The process of software development life cycle basically includes design, analysis, implementation, testing, and release phases. Generally, software testing is a critical task in the software development process wherein it is to save time and budget by detecting defects at the earliest and deliver a product without defects to the customers. This testing phase should be carefully operated in an effective manner to release a defect-free (bug-free) software product to the customers. In order to improve the software testing process, fault prediction methods identify the software parts that are more noted to be defect-prone. This paper proposes a prediction approach based on conventional radial basis function neural network (RBFNN) and the novel adaptive dimensional biogeography based optimization (ADBBO) model. The developed ADBBO based RBFNN model is tested with five publicly available datasets from the NASA data program repository. The computed results prove the effectiveness of the proposed ADBBO-RBFNN classifier approach with respect to the considered metrics in comparison with that of the early predictors available in the literature for the same datasets. PMID:27738649

  6. Cost-Sensitive Radial Basis Function Neural Network Classifier for Software Defect Prediction.

    PubMed

    Kumudha, P; Venkatesan, R

    Effective prediction of software modules, those that are prone to defects, will enable software developers to achieve efficient allocation of resources and to concentrate on quality assurance activities. The process of software development life cycle basically includes design, analysis, implementation, testing, and release phases. Generally, software testing is a critical task in the software development process wherein it is to save time and budget by detecting defects at the earliest and deliver a product without defects to the customers. This testing phase should be carefully operated in an effective manner to release a defect-free (bug-free) software product to the customers. In order to improve the software testing process, fault prediction methods identify the software parts that are more noted to be defect-prone. This paper proposes a prediction approach based on conventional radial basis function neural network (RBFNN) and the novel adaptive dimensional biogeography based optimization (ADBBO) model. The developed ADBBO based RBFNN model is tested with five publicly available datasets from the NASA data program repository. The computed results prove the effectiveness of the proposed ADBBO-RBFNN classifier approach with respect to the considered metrics in comparison with that of the early predictors available in the literature for the same datasets.

  7. CUQI: cardiac ultrasound video quality index

    PubMed Central

    Razaak, Manzoor; Martini, Maria G.

    2016-01-01

    Abstract. Medical images and videos are now increasingly part of modern telecommunication applications, including telemedicinal applications, favored by advancements in video compression and communication technologies. Medical video quality evaluation is essential for modern applications since compression and transmission processes often compromise the video quality. Several state-of-the-art video quality metrics used for quality evaluation assess the perceptual quality of the video. For a medical video, assessing quality in terms of “diagnostic” value rather than “perceptual” quality is more important. We present a diagnostic-quality–oriented video quality metric for quality evaluation of cardiac ultrasound videos. Cardiac ultrasound videos are characterized by rapid repetitive cardiac motions and distinct structural information characteristics that are explored by the proposed metric. Cardiac ultrasound video quality index, the proposed metric, is a full reference metric and uses the motion and edge information of the cardiac ultrasound video to evaluate the video quality. The metric was evaluated for its performance in approximating the quality of cardiac ultrasound videos by testing its correlation with the subjective scores of medical experts. The results of our tests showed that the metric has high correlation with medical expert opinions and in several cases outperforms the state-of-the-art video quality metrics considered in our tests. PMID:27014715

  8. Evaluating the Good Ontology Design Guideline (GoodOD) with the Ontology Quality Requirements and Evaluation Method and Metrics (OQuaRE)

    PubMed Central

    Duque-Ramos, Astrid; Boeker, Martin; Jansen, Ludger; Schulz, Stefan; Iniesta, Miguela; Fernández-Breis, Jesualdo Tomás

    2014-01-01

    Objective To (1) evaluate the GoodOD guideline for ontology development by applying the OQuaRE evaluation method and metrics to the ontology artefacts that were produced by students in a randomized controlled trial, and (2) informally compare the OQuaRE evaluation method with gold standard and competency questions based evaluation methods, respectively. Background In the last decades many methods for ontology construction and ontology evaluation have been proposed. However, none of them has become a standard and there is no empirical evidence of comparative evaluation of such methods. This paper brings together GoodOD and OQuaRE. GoodOD is a guideline for developing robust ontologies. It was previously evaluated in a randomized controlled trial employing metrics based on gold standard ontologies and competency questions as outcome parameters. OQuaRE is a method for ontology quality evaluation which adapts the SQuaRE standard for software product quality to ontologies and has been successfully used for evaluating the quality of ontologies. Methods In this paper, we evaluate the effect of training in ontology construction based on the GoodOD guideline within the OQuaRE quality evaluation framework and compare the results with those obtained for the previous studies based on the same data. Results Our results show a significant effect of the GoodOD training over developed ontologies by topics: (a) a highly significant effect was detected in three topics from the analysis of the ontologies of untrained and trained students; (b) both positive and negative training effects with respect to the gold standard were found for five topics. Conclusion The GoodOD guideline had a significant effect over the quality of the ontologies developed. Our results show that GoodOD ontologies can be effectively evaluated using OQuaRE and that OQuaRE is able to provide additional useful information about the quality of the GoodOD ontologies. PMID:25148262

  9. Evaluating the Good Ontology Design Guideline (GoodOD) with the ontology quality requirements and evaluation method and metrics (OQuaRE).

    PubMed

    Duque-Ramos, Astrid; Boeker, Martin; Jansen, Ludger; Schulz, Stefan; Iniesta, Miguela; Fernández-Breis, Jesualdo Tomás

    2014-01-01

    To (1) evaluate the GoodOD guideline for ontology development by applying the OQuaRE evaluation method and metrics to the ontology artefacts that were produced by students in a randomized controlled trial, and (2) informally compare the OQuaRE evaluation method with gold standard and competency questions based evaluation methods, respectively. In the last decades many methods for ontology construction and ontology evaluation have been proposed. However, none of them has become a standard and there is no empirical evidence of comparative evaluation of such methods. This paper brings together GoodOD and OQuaRE. GoodOD is a guideline for developing robust ontologies. It was previously evaluated in a randomized controlled trial employing metrics based on gold standard ontologies and competency questions as outcome parameters. OQuaRE is a method for ontology quality evaluation which adapts the SQuaRE standard for software product quality to ontologies and has been successfully used for evaluating the quality of ontologies. In this paper, we evaluate the effect of training in ontology construction based on the GoodOD guideline within the OQuaRE quality evaluation framework and compare the results with those obtained for the previous studies based on the same data. Our results show a significant effect of the GoodOD training over developed ontologies by topics: (a) a highly significant effect was detected in three topics from the analysis of the ontologies of untrained and trained students; (b) both positive and negative training effects with respect to the gold standard were found for five topics. The GoodOD guideline had a significant effect over the quality of the ontologies developed. Our results show that GoodOD ontologies can be effectively evaluated using OQuaRE and that OQuaRE is able to provide additional useful information about the quality of the GoodOD ontologies.

  10. Measuring the complexity of design in real-time imaging software

    NASA Astrophysics Data System (ADS)

    Sangwan, Raghvinder S.; Vercellone-Smith, Pamela; Laplante, Phillip A.

    2007-02-01

    Due to the intricacies in the algorithms involved, the design of imaging software is considered to be more complex than non-image processing software (Sangwan et al, 2005). A recent investigation (Larsson and Laplante, 2006) examined the complexity of several image processing and non-image processing software packages along a wide variety of metrics, including those postulated by McCabe (1976), Chidamber and Kemerer (1994), and Martin (2003). This work found that it was not always possible to quantitatively compare the complexity between imaging applications and nonimage processing systems. Newer research and an accompanying tool (Structure 101, 2006), however, provides a greatly simplified approach to measuring software complexity. Therefore it may be possible to definitively quantify the complexity differences between imaging and non-imaging software, between imaging and real-time imaging software, and between software programs of the same application type. In this paper, we review prior results and describe the methodology for measuring complexity in imaging systems. We then apply a new complexity measurement methodology to several sets of imaging and non-imaging code in order to compare the complexity differences between the two types of applications. The benefit of such quantification is far reaching, for example, leading to more easily measured performance improvement and quality in real-time imaging code.

  11. PICASSO: an end-to-end image simulation tool for space and airborne imaging systems

    NASA Astrophysics Data System (ADS)

    Cota, Steve A.; Bell, Jabin T.; Boucher, Richard H.; Dutton, Tracy E.; Florio, Chris J.; Franz, Geoffrey A.; Grycewicz, Thomas J.; Kalman, Linda S.; Keller, Robert A.; Lomheim, Terrence S.; Paulson, Diane B.; Willkinson, Timothy S.

    2008-08-01

    The design of any modern imaging system is the end result of many trade studies, each seeking to optimize image quality within real world constraints such as cost, schedule and overall risk. Image chain analysis - the prediction of image quality from fundamental design parameters - is an important part of this design process. At The Aerospace Corporation we have been using a variety of image chain analysis tools for many years, the Parameterized Image Chain Analysis & Simulation SOftware (PICASSO) among them. In this paper we describe our PICASSO tool, showing how, starting with a high quality input image and hypothetical design descriptions representative of the current state of the art in commercial imaging satellites, PICASSO can generate standard metrics of image quality in support of the decision processes of designers and program managers alike.

  12. PICASSO: an end-to-end image simulation tool for space and airborne imaging systems

    NASA Astrophysics Data System (ADS)

    Cota, Stephen A.; Bell, Jabin T.; Boucher, Richard H.; Dutton, Tracy E.; Florio, Christopher J.; Franz, Geoffrey A.; Grycewicz, Thomas J.; Kalman, Linda S.; Keller, Robert A.; Lomheim, Terrence S.; Paulson, Diane B.; Wilkinson, Timothy S.

    2010-06-01

    The design of any modern imaging system is the end result of many trade studies, each seeking to optimize image quality within real world constraints such as cost, schedule and overall risk. Image chain analysis - the prediction of image quality from fundamental design parameters - is an important part of this design process. At The Aerospace Corporation we have been using a variety of image chain analysis tools for many years, the Parameterized Image Chain Analysis & Simulation SOftware (PICASSO) among them. In this paper we describe our PICASSO tool, showing how, starting with a high quality input image and hypothetical design descriptions representative of the current state of the art in commercial imaging satellites, PICASSO can generate standard metrics of image quality in support of the decision processes of designers and program managers alike.

  13. Synthesized view comparison method for no-reference 3D image quality assessment

    NASA Astrophysics Data System (ADS)

    Luo, Fangzhou; Lin, Chaoyi; Gu, Xiaodong; Ma, Xiaojun

    2018-04-01

    We develop a no-reference image quality assessment metric to evaluate the quality of synthesized view rendered from the Multi-view Video plus Depth (MVD) format. Our metric is named Synthesized View Comparison (SVC), which is designed for real-time quality monitoring at the receiver side in a 3D-TV system. The metric utilizes the virtual views in the middle which are warped from left and right views by Depth-image-based rendering algorithm (DIBR), and compares the difference between the virtual views rendered from different cameras by Structural SIMilarity (SSIM), a popular 2D full-reference image quality assessment metric. The experimental results indicate that our no-reference quality assessment metric for the synthesized images has competitive prediction performance compared with some classic full-reference image quality assessment metrics.

  14. A Validation Metrics Framework for Safety-Critical Software-Intensive Systems

    DTIC Science & Technology

    2009-03-01

    so does its definition, tools, and techniques, including means for measuring the validation activity, its outputs, and impact on development...independent of the SDLP. When considering the above SDLPs from the safety engineering team’s perspective, there are also large impacts on the way... impact . Interpretation of any actionable metric data will need to be undertaken in the context of the SDLP. 2. Safety Input The software safety

  15. Metrics of a Paradigm for Intelligent Control

    NASA Technical Reports Server (NTRS)

    Hexmoor, Henry

    1999-01-01

    We present metrics for quantifying organizational structures of complex control systems intended for controlling long-lived robotic or other autonomous applications commonly found in space applications. Such advanced control systems are often called integration platforms or agent architectures. Reported metrics span concerns about time, resources, software engineering, and complexities in the world.

  16. Software engineering methodologies and tools

    NASA Technical Reports Server (NTRS)

    Wilcox, Lawrence M.

    1993-01-01

    Over the years many engineering disciplines have developed, including chemical, electronic, etc. Common to all engineering disciplines is the use of rigor, models, metrics, and predefined methodologies. Recently, a new engineering discipline has appeared on the scene, called software engineering. For over thirty years computer software has been developed and the track record has not been good. Software development projects often miss schedules, are over budget, do not give the user what is wanted, and produce defects. One estimate is there are one to three defects per 1000 lines of deployed code. More and more systems are requiring larger and more complex software for support. As this requirement grows, the software development problems grow exponentially. It is believed that software quality can be improved by applying engineering principles. Another compelling reason to bring the engineering disciplines to software development is productivity. It has been estimated that productivity of producing software has only increased one to two percent a year in the last thirty years. Ironically, the computer and its software have contributed significantly to the industry-wide productivity, but computer professionals have done a poor job of using the computer to do their job. Engineering disciplines and methodologies are now emerging supported by software tools that address the problems of software development. This paper addresses some of the current software engineering methodologies as a backdrop for the general evaluation of computer assisted software engineering (CASE) tools from actual installation of and experimentation with some specific tools.

  17. Toward a perceptual video-quality metric

    NASA Astrophysics Data System (ADS)

    Watson, Andrew B.

    1998-07-01

    The advent of widespread distribution of digital video creates a need for automated methods for evaluating the visual quality of digital video. This is particularly so since most digital video is compressed using lossy methods, which involve the controlled introduction of potentially visible artifacts. Compounding the problem is the bursty nature of digital video, which requires adaptive bit allocation based on visual quality metrics, and the economic need to reduce bit-rate to the lowest level that yields acceptable quality. In previous work, we have developed visual quality metrics for evaluating, controlling,a nd optimizing the quality of compressed still images. These metrics incorporate simplified models of human visual sensitivity to spatial and chromatic visual signals. Here I describe a new video quality metric that is an extension of these still image metrics into the time domain. Like the still image metrics, it is based on the Discrete Cosine Transform. An effort has been made to minimize the amount of memory and computation required by the metric, in order that might be applied in the widest range of applications. To calibrate the basic sensitivity of this metric to spatial and temporal signals we have made measurements of visual thresholds for temporally varying samples of DCT quantization noise.

  18. Effect of Pupil Size on Wavefront Refraction during Orthokeratology.

    PubMed

    Faria-Ribeiro, Miguel; Navarro, Rafael; González-Méijome, José Manuel

    2016-11-01

    It has been hypothesized that central and peripheral refraction, in eyes treated with myopic overnight orthokeratology, might vary with changes in pupil diameter. The aim of this work was to evaluate the axial and peripheral refraction and optical quality after orthokeratology, using ray tracing software for different pupil sizes. Zemax-EE was used to generate a series of 29 semi-customized model eyes based on the corneal topography changes from 29 patients who had undergone myopic orthokeratology. Wavefront refraction in the central 80 degrees of the visual field was calculated using three different quality metrics criteria: Paraxial curvature matching, minimum root mean square error (minRMS), and the Through Focus Visual Strehl of the Modulation Transfer Function (VSMTF), for 3- and 6-mm pupil diameters. The three metrics predicted significantly different values for foveal and peripheral refractions. Compared with the Paraxial criteria, the other two metrics predicted more myopic refractions on- and off-axis. Interestingly, the VSMTF predicts only a marginal myopic shift in the axial refraction as the pupil changes from 3 to 6 mm. For peripheral refraction, minRMS and VSMTF metric criteria predicted a higher exposure to peripheral defocus as the pupil increases from 3 to 6 mm. The results suggest that the supposed effect of myopic control produced by ortho-k treatments might be dependent on pupil size. Although the foveal refractive error does not seem to change appreciably with the increase in pupil diameter (VSMTF criteria), the high levels of positive spherical aberration will lead to a degradation of lower spatial frequencies, that is more significant under low illumination levels.

  19. Retrospective evaluation of dosimetric quality for prostate carcinomas treated with 3D conformal, intensity modulated and volumetric modulated arc radiotherapy

    PubMed Central

    Crowe, Scott B; Kairn, Tanya; Middlebrook, Nigel; Hill, Brendan; Christie, David R H; Knight, Richard T; Kenny, John; Langton, Christian M; Trapp, Jamie V

    2013-01-01

    Introduction This study examines and compares the dosimetric quality of radiotherapy treatment plans for prostate carcinoma across a cohort of 163 patients treated across five centres: 83 treated with three-dimensional conformal radiotherapy (3DCRT), 33 treated with intensity modulated radiotherapy (IMRT) and 47 treated with volumetric modulated arc therapy (VMAT). Methods Treatment plan quality was evaluated in terms of target dose homogeneity and organs at risk (OAR), through the use of a set of dose metrics. These included the mean, maximum and minimum doses; the homogeneity and conformity indices for the target volumes; and a selection of dose coverage values that were relevant to each OAR. Statistical significance was evaluated using two-tailed Welch's T-tests. The Monte Carlo DICOM ToolKit software was adapted to permit the evaluation of dose metrics from DICOM data exported from a commercial radiotherapy treatment planning system. Results The 3DCRT treatment plans offered greater planning target volume dose homogeneity than the other two treatment modalities. The IMRT and VMAT plans offered greater dose reduction in the OAR: with increased compliance with recommended OAR dose constraints, compared to conventional 3DCRT treatments. When compared to each other, IMRT and VMAT did not provide significantly different treatment plan quality for like-sized tumour volumes. Conclusions This study indicates that IMRT and VMAT have provided similar dosimetric quality, which is superior to the dosimetric quality achieved with 3DCRT. PMID:26229621

  20. Towards a Visual Quality Metric for Digital Video

    NASA Technical Reports Server (NTRS)

    Watson, Andrew B.

    1998-01-01

    The advent of widespread distribution of digital video creates a need for automated methods for evaluating visual quality of digital video. This is particularly so since most digital video is compressed using lossy methods, which involve the controlled introduction of potentially visible artifacts. Compounding the problem is the bursty nature of digital video, which requires adaptive bit allocation based on visual quality metrics. In previous work, we have developed visual quality metrics for evaluating, controlling, and optimizing the quality of compressed still images. These metrics incorporate simplified models of human visual sensitivity to spatial and chromatic visual signals. The challenge of video quality metrics is to extend these simplified models to temporal signals as well. In this presentation I will discuss a number of the issues that must be resolved in the design of effective video quality metrics. Among these are spatial, temporal, and chromatic sensitivity and their interactions, visual masking, and implementation complexity. I will also touch on the question of how to evaluate the performance of these metrics.

  1. Performance analysis of three-dimensional ridge acquisition from live finger and palm surface scans

    NASA Astrophysics Data System (ADS)

    Fatehpuria, Abhishika; Lau, Daniel L.; Yalla, Veeraganesh; Hassebrook, Laurence G.

    2007-04-01

    Fingerprints are one of the most commonly used and relied-upon biometric technology. But often the captured fingerprint image is far from ideal due to imperfect acquisition techniques that can be slow and cumbersome to use without providing complete fingerprint information. Most of the diffculties arise due to the contact of the fingerprint surface with the sensor platen. To overcome these diffculties we have been developing a noncontact scanning system for acquiring a 3-D scan of a finger with suffciently high resolution which is then converted into a 2-D rolled equivalent image. In this paper, we describe certain quantitative measures evaluating scanner performance. Specifically, we use some image software components developed by the National Institute of Standards and Technology, to derive our performance metrics. Out of the eleven identified metrics, three were found to be most suitable for evaluating scanner performance. A comparison is also made between 2D fingerprint images obtained by the traditional means and the 2D images obtained after unrolling the 3D scans and the quality of the acquired scans is quantified using the metrics.

  2. Bootstrapping Process Improvement Metrics: CMMI Level 4 Process Improvement Metrics in a Level 3 World

    NASA Technical Reports Server (NTRS)

    Hihn, Jairus; Lewicki, Scott; Morgan, Scott

    2011-01-01

    The measurement techniques for organizations which have achieved the Software Engineering Institutes CMMI Maturity Levels 4 and 5 are well documented. On the other hand, how to effectively measure when an organization is Maturity Level 3 is less well understood, especially when there is no consistency in tool use and there is extensive tailoring of the organizational software processes. Most organizations fail in their attempts to generate, collect, and analyze standard process improvement metrics under these conditions. But at JPL, NASA's prime center for deep space robotic exploration, we have a long history of proving there is always a solution: It just may not be what you expected. In this paper we describe the wide variety of qualitative and quantitative techniques we have been implementing over the last few years, including the various approaches used to communicate the results to both software technical managers and senior managers.

  3. The X-windows interactive navigation data editor

    NASA Technical Reports Server (NTRS)

    Rinker, G. C.

    1992-01-01

    A new computer program called the X-Windows Interactive Data Editor (XIDE) was developed and demonstrated as a prototype application for editing radio metric data in the orbit-determination process. The program runs on a variety of workstations and employs pull-down menus and graphical displays, which allow users to easily inspect and edit radio metric data in the orbit data files received from the Deep Space Network (DSN). The XIDE program is based on the Open Software Foundation OSF/Motif Graphical User Interface (GUI) and has proven to be an efficient tool for editing radio metric data in the navigation operations environment. It was adopted by the Magellan Navigation Team as their primary data-editing tool. Because the software was designed from the beginning to be portable, the prototype was successfully moved to new workstation environments. It was also itegrated into the design of the next-generation software tool for DSN multimission navigation interactive launch support.

  4. AdaMeasure: An Implementation of the Halstead and Henry Metrics.

    DTIC Science & Technology

    1987-06-01

    of Departne t o Computer Science Kneale T..Nar4 ___. Dean of Information and Policy bScic:-n-- 2 Allr ABSTRACT I A software metric is a tool that...CONTENTS INTRODUCTION AND BACKGROUND ......................... 6 A. DEFINITIONS ..................................................... 6 B. SALLIE HENRY’S...METRIC.................................... 6 C. INFORMATION FLOW .......................................... 7 D. RELATIONS

  5. Spiral model pilot project information model

    NASA Technical Reports Server (NTRS)

    1991-01-01

    The objective was an evaluation of the Spiral Model (SM) development approach to allow NASA Marshall to develop an experience base of that software management methodology. A discussion is presented of the Information Model (IM) that was used as part of the SM methodology. A key concept of the SM is the establishment of an IM to be used by management to track the progress of a project. The IM is the set of metrics that is to be measured and reported throughout the life of the project. These metrics measure both the product and the process to ensure the quality of the final delivery item and to ensure the project met programmatic guidelines. The beauty of the SM, along with the IM, is the ability to measure not only the correctness of the specification and implementation of the requirements but to also obtain a measure of customer satisfaction.

  6. Draft Software Metrics Panels Final Report. Papers Presented at the 30 June 1980 Meeting on Software Metrics, Washington DC.

    DTIC Science & Technology

    1980-06-01

    measuring program understanding. Shneiderman, Mayer, McKay, and Heller [241 found that flowcharts are redundant and have a potential negative affect on...dictionaries of program variables are superior to macro flowcharts as an aid to understand program control and data structures. Chrysler [5], using no...procedures as do beginners . Also; guaranteeing that groups of begining programmers have equal ability is not trivial. 3-10 The problem with material

  7. Analysis of Network Clustering Algorithms and Cluster Quality Metrics at Scale

    PubMed Central

    Kobourov, Stephen; Gallant, Mike; Börner, Katy

    2016-01-01

    Overview Notions of community quality underlie the clustering of networks. While studies surrounding network clustering are increasingly common, a precise understanding of the realtionship between different cluster quality metrics is unknown. In this paper, we examine the relationship between stand-alone cluster quality metrics and information recovery metrics through a rigorous analysis of four widely-used network clustering algorithms—Louvain, Infomap, label propagation, and smart local moving. We consider the stand-alone quality metrics of modularity, conductance, and coverage, and we consider the information recovery metrics of adjusted Rand score, normalized mutual information, and a variant of normalized mutual information used in previous work. Our study includes both synthetic graphs and empirical data sets of sizes varying from 1,000 to 1,000,000 nodes. Cluster Quality Metrics We find significant differences among the results of the different cluster quality metrics. For example, clustering algorithms can return a value of 0.4 out of 1 on modularity but score 0 out of 1 on information recovery. We find conductance, though imperfect, to be the stand-alone quality metric that best indicates performance on the information recovery metrics. Additionally, our study shows that the variant of normalized mutual information used in previous work cannot be assumed to differ only slightly from traditional normalized mutual information. Network Clustering Algorithms Smart local moving is the overall best performing algorithm in our study, but discrepancies between cluster evaluation metrics prevent us from declaring it an absolutely superior algorithm. Interestingly, Louvain performed better than Infomap in nearly all the tests in our study, contradicting the results of previous work in which Infomap was superior to Louvain. We find that although label propagation performs poorly when clusters are less clearly defined, it scales efficiently and accurately to large graphs with well-defined clusters. PMID:27391786

  8. A new normalizing algorithm for BAC CGH arrays with quality control metrics.

    PubMed

    Miecznikowski, Jeffrey C; Gaile, Daniel P; Liu, Song; Shepherd, Lori; Nowak, Norma

    2011-01-01

    The main focus in pin-tip (or print-tip) microarray analysis is determining which probes, genes, or oligonucleotides are differentially expressed. Specifically in array comparative genomic hybridization (aCGH) experiments, researchers search for chromosomal imbalances in the genome. To model this data, scientists apply statistical methods to the structure of the experiment and assume that the data consist of the signal plus random noise. In this paper we propose "SmoothArray", a new method to preprocess comparative genomic hybridization (CGH) bacterial artificial chromosome (BAC) arrays and we show the effects on a cancer dataset. As part of our R software package "aCGHplus," this freely available algorithm removes the variation due to the intensity effects, pin/print-tip, the spatial location on the microarray chip, and the relative location from the well plate. removal of this variation improves the downstream analysis and subsequent inferences made on the data. Further, we present measures to evaluate the quality of the dataset according to the arrayer pins, 384-well plates, plate rows, and plate columns. We compare our method against competing methods using several metrics to measure the biological signal. With this novel normalization algorithm and quality control measures, the user can improve their inferences on datasets and pinpoint problems that may arise in their BAC aCGH technology.

  9. A framework for assessing the adequacy and effectiveness of software development methodologies

    NASA Technical Reports Server (NTRS)

    Arthur, James D.; Nance, Richard E.

    1990-01-01

    Tools, techniques, environments, and methodologies dominate the software engineering literature, but relatively little research in the evaluation of methodologies is evident. This work reports an initial attempt to develop a procedural approach to evaluating software development methodologies. Prominent in this approach are: (1) an explication of the role of a methodology in the software development process; (2) the development of a procedure based on linkages among objectives, principles, and attributes; and (3) the establishment of a basis for reduction of the subjective nature of the evaluation through the introduction of properties. An application of the evaluation procedure to two Navy methodologies has provided consistent results that demonstrate the utility and versatility of the evaluation procedure. Current research efforts focus on the continued refinement of the evaluation procedure through the identification and integration of product quality indicators reflective of attribute presence, and the validation of metrics supporting the measure of those indicators. The consequent refinement of the evaluation procedure offers promise of a flexible approach that admits to change as the field of knowledge matures. In conclusion, the procedural approach presented in this paper represents a promising path toward the end goal of objectively evaluating software engineering methodologies.

  10. Application of Sigma Metrics Analysis for the Assessment and Modification of Quality Control Program in the Clinical Chemistry Laboratory of a Tertiary Care Hospital.

    PubMed

    Iqbal, Sahar; Mustansar, Tazeen

    2017-03-01

    Sigma is a metric that quantifies the performance of a process as a rate of Defects-Per-Million opportunities. In clinical laboratories, sigma metric analysis is used to assess the performance of laboratory process system. Sigma metric is also used as a quality management strategy for a laboratory process to improve the quality by addressing the errors after identification. The aim of this study is to evaluate the errors in quality control of analytical phase of laboratory system by sigma metric. For this purpose sigma metric analysis was done for analytes using the internal and external quality control as quality indicators. Results of sigma metric analysis were used to identify the gaps and need for modification in the strategy of laboratory quality control procedure. Sigma metric was calculated for quality control program of ten clinical chemistry analytes including glucose, chloride, cholesterol, triglyceride, HDL, albumin, direct bilirubin, total bilirubin, protein and creatinine, at two control levels. To calculate the sigma metric imprecision and bias was calculated with internal and external quality control data, respectively. The minimum acceptable performance was considered as 3 sigma. Westgard sigma rules were applied to customize the quality control procedure. Sigma level was found acceptable (≥3) for glucose (L2), cholesterol, triglyceride, HDL, direct bilirubin and creatinine at both levels of control. For rest of the analytes sigma metric was found <3. The lowest value for sigma was found for chloride (1.1) at L2. The highest value of sigma was found for creatinine (10.1) at L3. HDL was found with the highest sigma values at both control levels (8.8 and 8.0 at L2 and L3, respectively). We conclude that analytes with the sigma value <3 are required strict monitoring and modification in quality control procedure. In this study application of sigma rules provided us the practical solution for improved and focused design of QC procedure.

  11. The SHARPn Project on Secondary Use of Electronic Medical Record Data: Progress, Plans, and Possibilities

    PubMed Central

    Chute, Christopher G; Pathak, Jyotishman; Savova, Guergana K; Bailey, Kent R; Schor, Marshall I; Hart, Lacey A; Beebe, Calvin E; Huff, Stanley M

    2011-01-01

    SHARPn is a collaboration among 16 academic and industry partners committed to the production and distribution of high-quality software artifacts that support the secondary use of EMR data. Areas of emphasis are data normalization, natural language processing, high-throughput phenotyping, and data quality metrics. Our work avails the industrial scalability afforded by the Unstructured Information Management Architecture (UIMA) from IBM Watson Research labs, the same framework which underpins the Watson Jeopardy demonstration. This descriptive paper outlines our present work and achievements, and presages our trajectory for the remainder of the funding period. The project is one of the four Strategic Health IT Advanced Research Projects (SHARP) projects funded by the Office of the National Coordinator in 2010. PMID:22195076

  12. The SHARPn project on secondary use of Electronic Medical Record data: progress, plans, and possibilities.

    PubMed

    Chute, Christopher G; Pathak, Jyotishman; Savova, Guergana K; Bailey, Kent R; Schor, Marshall I; Hart, Lacey A; Beebe, Calvin E; Huff, Stanley M

    2011-01-01

    SHARPn is a collaboration among 16 academic and industry partners committed to the production and distribution of high-quality software artifacts that support the secondary use of EMR data. Areas of emphasis are data normalization, natural language processing, high-throughput phenotyping, and data quality metrics. Our work avails the industrial scalability afforded by the Unstructured Information Management Architecture (UIMA) from IBM Watson Research labs, the same framework which underpins the Watson Jeopardy demonstration. This descriptive paper outlines our present work and achievements, and presages our trajectory for the remainder of the funding period. The project is one of the four Strategic Health IT Advanced Research Projects (SHARP) projects funded by the Office of the National Coordinator in 2010.

  13. Automated Assessment of Visual Quality of Digital Video

    NASA Technical Reports Server (NTRS)

    Watson, Andrew B.; Ellis, Stephen R. (Technical Monitor)

    1997-01-01

    The advent of widespread distribution of digital video creates a need for automated methods for evaluating visual quality of digital video. This is particularly so since most digital video is compressed using lossy methods, which involve the controlled introduction of potentially visible artifacts. Compounding the problem is the bursty nature of digital video, which requires adaptive bit allocation based on visual quality metrics. In previous work, we have developed visual quality metrics for evaluating, controlling, and optimizing the quality of compressed still images[1-4]. These metrics incorporate simplified models of human visual sensitivity to spatial and chromatic visual signals. The challenge of video quality metrics is to extend these simplified models to temporal signals as well. In this presentation I will discuss a number of the issues that must be resolved in the design of effective video quality metrics. Among these are spatial, temporal, and chromatic sensitivity and their interactions, visual masking, and implementation complexity. I will also touch on the question of how to evaluate the performance of these metrics.

  14. The data quality analyzer: A quality control program for seismic data

    NASA Astrophysics Data System (ADS)

    Ringler, A. T.; Hagerty, M. T.; Holland, J.; Gonzales, A.; Gee, L. S.; Edwards, J. D.; Wilson, D.; Baker, A. M.

    2015-03-01

    The U.S. Geological Survey's Albuquerque Seismological Laboratory (ASL) has several initiatives underway to enhance and track the quality of data produced from ASL seismic stations and to improve communication about data problems to the user community. The Data Quality Analyzer (DQA) is one such development and is designed to characterize seismic station data quality in a quantitative and automated manner. The DQA consists of a metric calculator, a PostgreSQL database, and a Web interface: The metric calculator, SEEDscan, is a Java application that reads and processes miniSEED data and generates metrics based on a configuration file. SEEDscan compares hashes of metadata and data to detect changes in either and performs subsequent recalculations as needed. This ensures that the metric values are up to date and accurate. SEEDscan can be run as a scheduled task or on demand. The PostgreSQL database acts as a central hub where metric values and limited station descriptions are stored at the channel level with one-day granularity. The Web interface dynamically loads station data from the database and allows the user to make requests for time periods of interest, review specific networks and stations, plot metrics as a function of time, and adjust the contribution of various metrics to the overall quality grade of the station. The quantification of data quality is based on the evaluation of various metrics (e.g., timing quality, daily noise levels relative to long-term noise models, and comparisons between broadband data and event synthetics). Users may select which metrics contribute to the assessment and those metrics are aggregated into a "grade" for each station. The DQA is being actively used for station diagnostics and evaluation based on the completed metrics (availability, gap count, timing quality, deviation from a global noise model, deviation from a station noise model, coherence between co-located sensors, and comparison between broadband data and synthetics for earthquakes) on stations in the Global Seismographic Network and Advanced National Seismic System.

  15. Assessing efficiency of software production for NASA-SEL data

    NASA Technical Reports Server (NTRS)

    Vonmayrhauser, Anneliese; Roeseler, Armin

    1993-01-01

    This paper uses production models to identify and quantify efficient allocation of resources and key drivers of software productivity for project data in the NASA-SEL database. While analysis allows identification of efficient projects, many of the metrics that could have provided a more detailed analysis are not at a level of measurement to allow production model analysis. Production models must be used with proper parameterization to be successful. This may mean a new look at which metrics are helpful for efficiency assessment.

  16. Automated Method of Frequency Determination in Software Metric Data Through the Use of the Multiple Signal Classification (MUSIC) Algorithm

    DTIC Science & Technology

    1998-06-26

    METHOD OF FREQUENCY DETERMINATION 4 IN SOFTWARE METRIC DATA THROUGH THE USE OF THE 5 MULTIPLE SIGNAL CLASSIFICATION ( MUSIC ) ALGORITHM 6 7 STATEMENT OF...graph showing the estimated power spectral 12 density (PSD) generated by the multiple signal classification 13 ( MUSIC ) algorithm from the data set used...implemented in this module; however, it is preferred to use 1 the Multiple Signal Classification ( MUSIC ) algorithm. The MUSIC 2 algorithm is

  17. Vegetation Phenology Metrics Derived from Temporally Smoothed and Gap-filled MODIS Data

    NASA Technical Reports Server (NTRS)

    Tan, Bin; Morisette, Jeff; Wolfe, Robert; Esaias, Wayne; Gao, Feng; Ederer, Greg; Nightingale, Joanne; Nickeson, Jamie E.; Ma, Pete; Pedely, Jeff

    2012-01-01

    Smoothed and gap-filled VI provides a good base for estimating vegetation phenology metrics. The TIMESAT software was improved by incorporating the ancillary information from MODIS products. A simple assessment of the association between retrieved greenup dates and ground observations indicates satisfactory result from improved TIMESAT software. One application example shows that mapping Nectar Flow Phenology is tractable on a continental scale using hive weight and satellite vegetation data. The phenology data product is supporting more researches in ecology, climate change fields.

  18. Research on quality metrics of wireless adaptive video streaming

    NASA Astrophysics Data System (ADS)

    Li, Xuefei

    2018-04-01

    With the development of wireless networks and intelligent terminals, video traffic has increased dramatically. Adaptive video streaming has become one of the most promising video transmission technologies. For this type of service, a good QoS (Quality of Service) of wireless network does not always guarantee that all customers have good experience. Thus, new quality metrics have been widely studies recently. Taking this into account, the objective of this paper is to investigate the quality metrics of wireless adaptive video streaming. In this paper, a wireless video streaming simulation platform with DASH mechanism and multi-rate video generator is established. Based on this platform, PSNR model, SSIM model and Quality Level model are implemented. Quality Level Model considers the QoE (Quality of Experience) factors such as image quality, stalling and switching frequency while PSNR Model and SSIM Model mainly consider the quality of the video. To evaluate the performance of these QoE models, three performance metrics (SROCC, PLCC and RMSE) which are used to make a comparison of subjective and predicted MOS (Mean Opinion Score) are calculated. From these performance metrics, the monotonicity, linearity and accuracy of these quality metrics can be observed.

  19. Data-driven management using quantitative metric and automatic auditing program (QMAP) improves consistency of radiation oncology processes.

    PubMed

    Yu, Naichang; Xia, Ping; Mastroianni, Anthony; Kolar, Matthew D; Chao, Samuel T; Greskovich, John F; Suh, John H

    Process consistency in planning and delivery of radiation therapy is essential to maintain patient safety and treatment quality and efficiency. Ensuring the timely completion of each critical clinical task is one aspect of process consistency. The purpose of this work is to report our experience in implementing a quantitative metric and automatic auditing program (QMAP) with a goal of improving the timely completion of critical clinical tasks. Based on our clinical electronic medical records system, we developed a software program to automatically capture the completion timestamp of each critical clinical task while providing frequent alerts of potential delinquency. These alerts were directed to designated triage teams within a time window that would offer an opportunity to mitigate the potential for late completion. Since July 2011, 18 metrics were introduced in our clinical workflow. We compared the delinquency rates for 4 selected metrics before the implementation of the metric with the delinquency rate of 2016. One-tailed Student t test was used for statistical analysis RESULTS: With an average of 150 daily patients on treatment at our main campus, the late treatment plan completion rate and late weekly physics check were reduced from 18.2% and 8.9% in 2011 to 4.2% and 0.1% in 2016, respectively (P < .01). The late weekly on-treatment physician visit rate was reduced from 7.2% in 2012 to <1.6% in 2016. The yearly late cone beam computed tomography review rate was reduced from 1.6% in 2011 to <0.1% in 2016. QMAP is effective in reducing late completions of critical tasks, which can positively impact treatment quality and patient safety by reducing the potential for errors resulting from distractions, interruptions, and rush in completion of critical tasks. Copyright © 2016 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  20. [Clinical trial data management and quality metrics system].

    PubMed

    Chen, Zhao-hua; Huang, Qin; Deng, Ya-zhong; Zhang, Yue; Xu, Yu; Yu, Hao; Liu, Zong-fan

    2015-11-01

    Data quality management system is essential to ensure accurate, complete, consistent, and reliable data collection in clinical research. This paper is devoted to various choices of data quality metrics. They are categorized by study status, e.g. study start up, conduct, and close-out. In each category, metrics for different purposes are listed according to ALCOA+ principles such us completeness, accuracy, timeliness, traceability, etc. Some general quality metrics frequently used are also introduced. This paper contains detail information as much as possible to each metric by providing definition, purpose, evaluation, referenced benchmark, and recommended targets in favor of real practice. It is important that sponsors and data management service providers establish a robust integrated clinical trial data quality management system to ensure sustainable high quality of clinical trial deliverables. It will also support enterprise level of data evaluation and bench marking the quality of data across projects, sponsors, data management service providers by using objective metrics from the real clinical trials. We hope this will be a significant input to accelerate the improvement of clinical trial data quality in the industry.

  1. Kepler Planet Detection Metrics: Statistical Bootstrap Test

    NASA Technical Reports Server (NTRS)

    Jenkins, Jon M.; Burke, Christopher J.

    2016-01-01

    This document describes the data produced by the Statistical Bootstrap Test over the final three Threshold Crossing Event (TCE) deliveries to NExScI: SOC 9.1 (Q1Q16)1 (Tenenbaum et al. 2014), SOC 9.2 (Q1Q17) aka DR242 (Seader et al. 2015), and SOC 9.3 (Q1Q17) aka DR253 (Twicken et al. 2016). The last few years have seen significant improvements in the SOC science data processing pipeline, leading to higher quality light curves and more sensitive transit searches. The statistical bootstrap analysis results presented here and the numerical results archived at NASAs Exoplanet Science Institute (NExScI) bear witness to these software improvements. This document attempts to introduce and describe the main features and differences between these three data sets as a consequence of the software changes.

  2. Quality metrics in high-dimensional data visualization: an overview and systematization.

    PubMed

    Bertini, Enrico; Tatu, Andrada; Keim, Daniel

    2011-12-01

    In this paper, we present a systematization of techniques that use quality metrics to help in the visual exploration of meaningful patterns in high-dimensional data. In a number of recent papers, different quality metrics are proposed to automate the demanding search through large spaces of alternative visualizations (e.g., alternative projections or ordering), allowing the user to concentrate on the most promising visualizations suggested by the quality metrics. Over the last decade, this approach has witnessed a remarkable development but few reflections exist on how these methods are related to each other and how the approach can be developed further. For this purpose, we provide an overview of approaches that use quality metrics in high-dimensional data visualization and propose a systematization based on a thorough literature review. We carefully analyze the papers and derive a set of factors for discriminating the quality metrics, visualization techniques, and the process itself. The process is described through a reworked version of the well-known information visualization pipeline. We demonstrate the usefulness of our model by applying it to several existing approaches that use quality metrics, and we provide reflections on implications of our model for future research. © 2010 IEEE

  3. SU-F-I-43: A Software-Based Statistical Method to Compute Low Contrast Detectability in Computed Tomography Images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chacko, M; Aldoohan, S

    Purpose: The low contrast detectability (LCD) of a CT scanner is its ability to detect and display faint lesions. The current approach to quantify LCD is achieved using vendor-specific methods and phantoms, typically by subjectively observing the smallest size object at a contrast level above phantom background. However, this approach does not yield clinically applicable values for LCD. The current study proposes a statistical LCD metric using software tools to not only to assess scanner performance, but also to quantify the key factors affecting LCD. This approach was developed using uniform QC phantoms, and its applicability was then extended undermore » simulated clinical conditions. Methods: MATLAB software was developed to compute LCD using a uniform image of a QC phantom. For a given virtual object size, the software randomly samples the image within a selected area, and uses statistical analysis based on Student’s t-distribution to compute the LCD as the minimal Hounsfield Unit’s that can be distinguished from the background at the 95% confidence level. Its validity was assessed by comparison with the behavior of a known QC phantom under various scan protocols and a tissue-mimicking phantom. The contributions of beam quality and scattered radiation upon the computed LCD were quantified by using various external beam-hardening filters and phantom lengths. Results: As expected, the LCD was inversely related to object size under all scan conditions. The type of image reconstruction kernel filter and tissue/organ type strongly influenced the background noise characteristics and therefore, the computed LCD for the associated image. Conclusion: The proposed metric and its associated software tools are vendor-independent and can be used to analyze any LCD scanner performance. Furthermore, the method employed can be used in conjunction with the relationships established in this study between LCD and tissue type to extend these concepts to patients’ clinical CT images.« less

  4. Sigma metrics used to assess analytical quality of clinical chemistry assays: importance of the allowable total error (TEa) target.

    PubMed

    Hens, Koen; Berth, Mario; Armbruster, Dave; Westgard, Sten

    2014-07-01

    Six Sigma metrics were used to assess the analytical quality of automated clinical chemistry and immunoassay tests in a large Belgian clinical laboratory and to explore the importance of the source used for estimation of the allowable total error. Clinical laboratories are continually challenged to maintain analytical quality. However, it is difficult to measure assay quality objectively and quantitatively. The Sigma metric is a single number that estimates quality based on the traditional parameters used in the clinical laboratory: allowable total error (TEa), precision and bias. In this study, Sigma metrics were calculated for 41 clinical chemistry assays for serum and urine on five ARCHITECT c16000 chemistry analyzers. Controls at two analyte concentrations were tested and Sigma metrics were calculated using three different TEa targets (Ricos biological variability, CLIA, and RiliBÄK). Sigma metrics varied with analyte concentration, the TEa target, and between/among analyzers. Sigma values identified those assays that are analytically robust and require minimal quality control rules and those that exhibit more variability and require more complex rules. The analyzer to analyzer variability was assessed on the basis of Sigma metrics. Six Sigma is a more efficient way to control quality, but the lack of TEa targets for many analytes and the sometimes inconsistent TEa targets from different sources are important variables for the interpretation and the application of Sigma metrics in a routine clinical laboratory. Sigma metrics are a valuable means of comparing the analytical quality of two or more analyzers to ensure the comparability of patient test results.

  5. A software technology evaluation program

    NASA Technical Reports Server (NTRS)

    Novaes-Card, David N.

    1985-01-01

    A set of quantitative approaches is presented for evaluating software development methods and tools. The basic idea is to generate a set of goals which are refined into quantifiable questions which specify metrics to be collected on the software development and maintenance process and product. These metrics can be used to characterize, evaluate, predict, and motivate. They can be used in an active as well as passive way by learning form analyzing the data and improving the methods and tools based upon what is learned from that analysis. Several examples were given representing each of the different approaches to evaluation. The cost of the approaches varied inversely with the level of confidence in the interpretation of the results.

  6. Software risk management through independent verification and validation

    NASA Technical Reports Server (NTRS)

    Callahan, John R.; Zhou, Tong C.; Wood, Ralph

    1995-01-01

    Software project managers need tools to estimate and track project goals in a continuous fashion before, during, and after development of a system. In addition, they need an ability to compare the current project status with past project profiles to validate management intuition, identify problems, and then direct appropriate resources to the sources of problems. This paper describes a measurement-based approach to calculating the risk inherent in meeting project goals that leverages past project metrics and existing estimation and tracking models. We introduce the IV&V Goal/Questions/Metrics model, explain its use in the software development life cycle, and describe our attempts to validate the model through the reverse engineering of existing projects.

  7. Measuring the software process and product: Lessons learned in the SEL

    NASA Technical Reports Server (NTRS)

    Basili, V. R.

    1985-01-01

    The software development process and product can and should be measured. The software measurement process at the Software Engineering Laboratory (SEL) has taught a major lesson: develop a goal-driven paradigm (also characterized as a goal/question/metric paradigm) for data collection. Project analysis under this paradigm leads to a design for evaluating and improving the methodology of software development and maintenance.

  8. Quality assessment for color reproduction using a blind metric

    NASA Astrophysics Data System (ADS)

    Bringier, B.; Quintard, L.; Larabi, M.-C.

    2007-01-01

    This paper deals with image quality assessment. This field plays nowadays an important role in various image processing applications. Number of objective image quality metrics, that correlate or not, with the subjective quality have been developed during the last decade. Two categories of metrics can be distinguished, the first with full-reference and the second with no-reference. Full-reference metric tries to evaluate the distortion introduced to an image with regards to the reference. No-reference approach attempts to model the judgment of image quality in a blind way. Unfortunately, the universal image quality model is not on the horizon and empirical models established on psychophysical experimentation are generally used. In this paper, we focus only on the second category to evaluate the quality of color reproduction where a blind metric, based on human visual system modeling is introduced. The objective results are validated by single-media and cross-media subjective tests.

  9. Performance comparison of AV1, HEVC, and JVET video codecs on 360 (spherical) video

    NASA Astrophysics Data System (ADS)

    Topiwala, Pankaj; Dai, Wei; Krishnan, Madhu; Abbas, Adeel; Doshi, Sandeep; Newman, David

    2017-09-01

    This paper compares the coding efficiency performance on 360 videos, of three software codecs: (a) AV1 video codec from the Alliance for Open Media (AOM); (b) the HEVC Reference Software HM; and (c) the JVET JEM Reference SW. Note that 360 video is especially challenging content, in that one codes full res globally, but typically looks locally (in a viewport), which magnifies errors. These are tested in two different projection formats ERP and RSP, to check consistency. Performance is tabulated for 1-pass encoding on two fronts: (1) objective performance based on end-to-end (E2E) metrics such as SPSNR-NN, and WS-PSNR, currently developed in the JVET committee; and (2) informal subjective assessment of static viewports. Constant quality encoding is performed with all the three codecs for an unbiased comparison of the core coding tools. Our general conclusion is that under constant quality coding, AV1 underperforms HEVC, which underperforms JVET. We also test with rate control, where AV1 currently underperforms the open source X265 HEVC codec. Objective and visual evidence is provided.

  10. Image Quality Ranking Method for Microscopy

    PubMed Central

    Koho, Sami; Fazeli, Elnaz; Eriksson, John E.; Hänninen, Pekka E.

    2016-01-01

    Automated analysis of microscope images is necessitated by the increased need for high-resolution follow up of events in time. Manually finding the right images to be analyzed, or eliminated from data analysis are common day-to-day problems in microscopy research today, and the constantly growing size of image datasets does not help the matter. We propose a simple method and a software tool for sorting images within a dataset, according to their relative quality. We demonstrate the applicability of our method in finding good quality images in a STED microscope sample preparation optimization image dataset. The results are validated by comparisons to subjective opinion scores, as well as five state-of-the-art blind image quality assessment methods. We also show how our method can be applied to eliminate useless out-of-focus images in a High-Content-Screening experiment. We further evaluate the ability of our image quality ranking method to detect out-of-focus images, by extensive simulations, and by comparing its performance against previously published, well-established microscopy autofocus metrics. PMID:27364703

  11. An objective method for a video quality evaluation in a 3DTV service

    NASA Astrophysics Data System (ADS)

    Wilczewski, Grzegorz

    2015-09-01

    The following article describes proposed objective method for a 3DTV video quality evaluation, a Compressed Average Image Intensity (CAII) method. Identification of the 3DTV service's content chain nodes enables to design a versatile, objective video quality metric. It is based on an advanced approach to the stereoscopic videostream analysis. Insights towards designed metric mechanisms, as well as the evaluation of performance of the designed video quality metric, in the face of the simulated environmental conditions are herein discussed. As a result, created CAII metric might be effectively used in a variety of service quality assessment applications.

  12. a Critical Review of Automated Photogrammetric Processing of Large Datasets

    NASA Astrophysics Data System (ADS)

    Remondino, F.; Nocerino, E.; Toschi, I.; Menna, F.

    2017-08-01

    The paper reports some comparisons between commercial software able to automatically process image datasets for 3D reconstruction purposes. The main aspects investigated in the work are the capability to correctly orient large sets of image of complex environments, the metric quality of the results, replicability and redundancy. Different datasets are employed, each one featuring a diverse number of images, GSDs at cm and mm resolutions, and ground truth information to perform statistical analyses of the 3D results. A summary of (photogrammetric) terms is also provided, in order to provide rigorous terms of reference for comparisons and critical analyses.

  13. An Underwater Color Image Quality Evaluation Metric.

    PubMed

    Yang, Miao; Sowmya, Arcot

    2015-12-01

    Quality evaluation of underwater images is a key goal of underwater video image retrieval and intelligent processing. To date, no metric has been proposed for underwater color image quality evaluation (UCIQE). The special absorption and scattering characteristics of the water medium do not allow direct application of natural color image quality metrics especially to different underwater environments. In this paper, subjective testing for underwater image quality has been organized. The statistical distribution of the underwater image pixels in the CIELab color space related to subjective evaluation indicates the sharpness and colorful factors correlate well with subjective image quality perception. Based on these, a new UCIQE metric, which is a linear combination of chroma, saturation, and contrast, is proposed to quantify the non-uniform color cast, blurring, and low-contrast that characterize underwater engineering and monitoring images. Experiments are conducted to illustrate the performance of the proposed UCIQE metric and its capability to measure the underwater image enhancement results. They show that the proposed metric has comparable performance to the leading natural color image quality metrics and the underwater grayscale image quality metrics available in the literature, and can predict with higher accuracy the relative amount of degradation with similar image content in underwater environments. Importantly, UCIQE is a simple and fast solution for real-time underwater video processing. The effectiveness of the presented measure is also demonstrated by subjective evaluation. The results show better correlation between the UCIQE and the subjective mean opinion score.

  14. A no-reference video quality assessment metric based on ROI

    NASA Astrophysics Data System (ADS)

    Jia, Lixiu; Zhong, Xuefei; Tu, Yan; Niu, Wenjuan

    2015-01-01

    A no reference video quality assessment metric based on the region of interest (ROI) was proposed in this paper. In the metric, objective video quality was evaluated by integrating the quality of two compressed artifacts, i.e. blurring distortion and blocking distortion. The Gaussian kernel function was used to extract the human density maps of the H.264 coding videos from the subjective eye tracking data. An objective bottom-up ROI extraction model based on magnitude discrepancy of discrete wavelet transform between two consecutive frames, center weighted color opponent model, luminance contrast model and frequency saliency model based on spectral residual was built. Then only the objective saliency maps were used to compute the objective blurring and blocking quality. The results indicate that the objective ROI extraction metric has a higher the area under the curve (AUC) value. Comparing with the conventional video quality assessment metrics which measured all the video quality frames, the metric proposed in this paper not only decreased the computation complexity, but improved the correlation between subjective mean opinion score (MOS) and objective scores.

  15. Source Lines Counter (SLiC) Version 4.0

    NASA Technical Reports Server (NTRS)

    Monson, Erik W.; Smith, Kevin A.; Newport, Brian J.; Gostelow, Roli D.; Hihn, Jairus M.; Kandt, Ronald K.

    2011-01-01

    Source Lines Counter (SLiC) is a software utility designed to measure software source code size using logical source statements and other common measures for 22 of the programming languages commonly used at NASA and the aerospace industry. Such metrics can be used in a wide variety of applications, from parametric cost estimation to software defect analysis. SLiC has a variety of unique features such as automatic code search, automatic file detection, hierarchical directory totals, and spreadsheet-compatible output. SLiC was written for extensibility; new programming language support can be added with minimal effort in a short amount of time. SLiC runs on a variety of platforms including UNIX, Windows, and Mac OSX. Its straightforward command-line interface allows for customization and incorporation into the software build process for tracking development metrics. T

  16. Analysis of Network Clustering Algorithms and Cluster Quality Metrics at Scale.

    PubMed

    Emmons, Scott; Kobourov, Stephen; Gallant, Mike; Börner, Katy

    2016-01-01

    Notions of community quality underlie the clustering of networks. While studies surrounding network clustering are increasingly common, a precise understanding of the realtionship between different cluster quality metrics is unknown. In this paper, we examine the relationship between stand-alone cluster quality metrics and information recovery metrics through a rigorous analysis of four widely-used network clustering algorithms-Louvain, Infomap, label propagation, and smart local moving. We consider the stand-alone quality metrics of modularity, conductance, and coverage, and we consider the information recovery metrics of adjusted Rand score, normalized mutual information, and a variant of normalized mutual information used in previous work. Our study includes both synthetic graphs and empirical data sets of sizes varying from 1,000 to 1,000,000 nodes. We find significant differences among the results of the different cluster quality metrics. For example, clustering algorithms can return a value of 0.4 out of 1 on modularity but score 0 out of 1 on information recovery. We find conductance, though imperfect, to be the stand-alone quality metric that best indicates performance on the information recovery metrics. Additionally, our study shows that the variant of normalized mutual information used in previous work cannot be assumed to differ only slightly from traditional normalized mutual information. Smart local moving is the overall best performing algorithm in our study, but discrepancies between cluster evaluation metrics prevent us from declaring it an absolutely superior algorithm. Interestingly, Louvain performed better than Infomap in nearly all the tests in our study, contradicting the results of previous work in which Infomap was superior to Louvain. We find that although label propagation performs poorly when clusters are less clearly defined, it scales efficiently and accurately to large graphs with well-defined clusters.

  17. Relative Utility of Selected Software Requirement Metrics

    DTIC Science & Technology

    1991-12-01

    testing . They can also help in deciding if and how to use complexity reduction techniques. In summary, requirement metrics can be useful because they...answer items in a test instrument. In order to differentiate between misinterpretation and comprehension, the measurement technique must be able to...effectively test a requirement, it is verifiable. Ramamoorthy and others have proposed requirements complexity metrics that can be used to infer the

  18. Enhancements and Extensions of Formal Models for Risk Assessment in Software Projects

    DTIC Science & Technology

    2002-09-01

    the five defect categories. Cosmetic Defects. The name that corresponds to QSM®’s cosmetic defects. Cosmetic defects can be described as deferred...California. June 2002. (Fent00) Fenton , N. E. and Neil, M., Software Metrics: Roadmap. Proceedings of the Conference on the Future of Software

  19. Attack-Resistant Trust Metrics

    NASA Astrophysics Data System (ADS)

    Levien, Raph

    The Internet is an amazingly powerful tool for connecting people together, unmatched in human history. Yet, with that power comes great potential for spam and abuse. Trust metrics are an attempt to compute the set of which people are trustworthy and which are likely attackers. This chapter presents two specific trust metrics developed and deployed on the Advogato Website, which is a community blog for free software developers. This real-world experience demonstrates that the trust metrics fulfilled their goals, but that for good results, it is important to match the assumptions of the abstract trust metric computation to the real-world implementation.

  20. A guide to calculating habitat-quality metrics to inform conservation of highly mobile species

    USGS Publications Warehouse

    Bieri, Joanna A.; Sample, Christine; Thogmartin, Wayne E.; Diffendorfer, James E.; Earl, Julia E.; Erickson, Richard A.; Federico, Paula; Flockhart, D. T. Tyler; Nicol, Sam; Semmens, Darius J.; Skraber, T.; Wiederholt, Ruscena; Mattsson, Brady J.

    2018-01-01

    Many metrics exist for quantifying the relative value of habitats and pathways used by highly mobile species. Properly selecting and applying such metrics requires substantial background in mathematics and understanding the relevant management arena. To address this multidimensional challenge, we demonstrate and compare three measurements of habitat quality: graph-, occupancy-, and demographic-based metrics. Each metric provides insights into system dynamics, at the expense of increasing amounts and complexity of data and models. Our descriptions and comparisons of diverse habitat-quality metrics provide means for practitioners to overcome the modeling challenges associated with management or conservation of such highly mobile species. Whereas previous guidance for applying habitat-quality metrics has been scattered in diversified tracks of literature, we have brought this information together into an approachable format including accessible descriptions and a modeling case study for a typical example that conservation professionals can adapt for their own decision contexts and focal populations.Considerations for Resource ManagersManagement objectives, proposed actions, data availability and quality, and model assumptions are all relevant considerations when applying and interpreting habitat-quality metrics.Graph-based metrics answer questions related to habitat centrality and connectivity, are suitable for populations with any movement pattern, quantify basic spatial and temporal patterns of occupancy and movement, and require the least data.Occupancy-based metrics answer questions about likelihood of persistence or colonization, are suitable for populations that undergo localized extinctions, quantify spatial and temporal patterns of occupancy and movement, and require a moderate amount of data.Demographic-based metrics answer questions about relative or absolute population size, are suitable for populations with any movement pattern, quantify demographic processes and population dynamics, and require the most data.More real-world examples applying occupancy-based, agent-based, and continuous-based metrics to seasonally migratory species are needed to better understand challenges and opportunities for applying these metrics more broadly.

  1. A no-reference image and video visual quality metric based on machine learning

    NASA Astrophysics Data System (ADS)

    Frantc, Vladimir; Voronin, Viacheslav; Semenishchev, Evgenii; Minkin, Maxim; Delov, Aliy

    2018-04-01

    The paper presents a novel visual quality metric for lossy compressed video quality assessment. High degree of correlation with subjective estimations of quality is due to using of a convolutional neural network trained on a large amount of pairs video sequence-subjective quality score. We demonstrate how our predicted no-reference quality metric correlates with qualitative opinion in a human observer study. Results are shown on the EVVQ dataset with comparison existing approaches.

  2. Defining quality metrics and improving safety and outcome in allergy care.

    PubMed

    Lee, Stella; Stachler, Robert J; Ferguson, Berrylin J

    2014-04-01

    The delivery of allergy immunotherapy in the otolaryngology office is variable and lacks standardization. Quality metrics encompasses the measurement of factors associated with good patient-centered care. These factors have yet to be defined in the delivery of allergy immunotherapy. We developed and applied quality metrics to 6 allergy practices affiliated with an academic otolaryngic allergy center. This work was conducted at a tertiary academic center providing care to over 1500 patients. We evaluated methods and variability between 6 sites. Tracking of errors and anaphylaxis was initiated across all sites. A nationwide survey of academic and private allergists was used to collect data on current practice and use of quality metrics. The most common types of errors recorded were patient identification errors (n = 4), followed by vial mixing errors (n = 3), and dosing errors (n = 2). There were 7 episodes of anaphylaxis of which 2 were secondary to dosing errors for a rate of 0.01% or 1 in every 10,000 injection visits/year. Site visits showed that 86% of key safety measures were followed. Analysis of nationwide survey responses revealed that quality metrics are still not well defined by either medical or otolaryngic allergy practices. Academic practices were statistically more likely to use quality metrics (p = 0.021) and perform systems reviews and audits in comparison to private practices (p = 0.005). Quality metrics in allergy delivery can help improve safety and quality care. These metrics need to be further defined by otolaryngic allergists in the changing health care environment. © 2014 ARS-AAOA, LLC.

  3. Development of Management Metrics for Research and Technology

    NASA Technical Reports Server (NTRS)

    Sheskin, Theodore J.

    2003-01-01

    Professor Ted Sheskin from CSU will be tasked to research and investigate metrics that can be used to determine the technical progress for advanced development and research tasks. These metrics will be implemented in a software environment that hosts engineering design, analysis and management tools to be used to support power system and component research work at GRC. Professor Sheskin is an Industrial Engineer and has been involved in issues related to management of engineering tasks and will use his knowledge from this area to allow extrapolation into the research and technology management area. Over the course of the summer, Professor Sheskin will develop a bibliography of management papers covering current management methods that may be applicable to research management. At the completion of the summer work we expect to have him recommend a metric system to be reviewed prior to implementation in the software environment. This task has been discussed with Professor Sheskin and some review material has already been given to him.

  4. R&D100: Lightweight Distributed Metric Service

    ScienceCinema

    Gentile, Ann; Brandt, Jim; Tucker, Tom; Showerman, Mike

    2018-06-12

    On today's High Performance Computing platforms, the complexity of applications and configurations makes efficient use of resources difficult. The Lightweight Distributed Metric Service (LDMS) is monitoring software developed by Sandia National Laboratories to provide detailed metrics of system performance. LDMS provides collection, transport, and storage of data from extreme-scale systems at fidelities and timescales to provide understanding of application and system performance with no statistically significant impact on application performance.

  5. R&D100: Lightweight Distributed Metric Service

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gentile, Ann; Brandt, Jim; Tucker, Tom

    2015-11-19

    On today's High Performance Computing platforms, the complexity of applications and configurations makes efficient use of resources difficult. The Lightweight Distributed Metric Service (LDMS) is monitoring software developed by Sandia National Laboratories to provide detailed metrics of system performance. LDMS provides collection, transport, and storage of data from extreme-scale systems at fidelities and timescales to provide understanding of application and system performance with no statistically significant impact on application performance.

  6. Quality evaluation of extracted ion chromatograms and chromatographic peaks in liquid chromatography/mass spectrometry-based metabolomics data

    PubMed Central

    2014-01-01

    Background Extracted ion chromatogram (EIC) extraction and chromatographic peak detection are two important processing procedures in liquid chromatography/mass spectrometry (LC/MS)-based metabolomics data analysis. Most commonly, the LC/MS technique employs electrospray ionization as the ionization method. The EICs from LC/MS data are often noisy and contain high background signals. Furthermore, the chromatographic peak quality varies with respect to its location in the chromatogram and most peaks have zigzag shapes. Therefore, there is a critical need to develop effective metrics for quality evaluation of EICs and chromatographic peaks in LC/MS based metabolomics data analysis. Results We investigated a comprehensive set of potential quality evaluation metrics for extracted EICs and detected chromatographic peaks. Specifically, for EIC quality evaluation, we analyzed the mass chromatographic quality index (MCQ index) and propose a novel quality evaluation metric, the EIC-related global zigzag index, which is based on an EIC's first order derivatives. For chromatographic peak quality evaluation, we analyzed and compared six metrics: sharpness, Gaussian similarity, signal-to-noise ratio, peak significance level, triangle peak area similarity ratio and the local peak-related local zigzag index. Conclusions Although the MCQ index is suited for selecting and aligning analyte components, it cannot fairly evaluate EICs with high background signals or those containing only a single peak. Our proposed EIC related global zigzag index is robust enough to evaluate EIC qualities in both scenarios. Of the six peak quality evaluation metrics, the sharpness, peak significance level, and zigzag index outperform the others due to the zigzag nature of LC/MS chromatographic peaks. Furthermore, using several peak quality metrics in combination is more efficient than individual metrics in peak quality evaluation. PMID:25350128

  7. Quality evaluation of extracted ion chromatograms and chromatographic peaks in liquid chromatography/mass spectrometry-based metabolomics data.

    PubMed

    Zhang, Wenchao; Zhao, Patrick X

    2014-01-01

    Extracted ion chromatogram (EIC) extraction and chromatographic peak detection are two important processing procedures in liquid chromatography/mass spectrometry (LC/MS)-based metabolomics data analysis. Most commonly, the LC/MS technique employs electrospray ionization as the ionization method. The EICs from LC/MS data are often noisy and contain high background signals. Furthermore, the chromatographic peak quality varies with respect to its location in the chromatogram and most peaks have zigzag shapes. Therefore, there is a critical need to develop effective metrics for quality evaluation of EICs and chromatographic peaks in LC/MS based metabolomics data analysis. We investigated a comprehensive set of potential quality evaluation metrics for extracted EICs and detected chromatographic peaks. Specifically, for EIC quality evaluation, we analyzed the mass chromatographic quality index (MCQ index) and propose a novel quality evaluation metric, the EIC-related global zigzag index, which is based on an EIC's first order derivatives. For chromatographic peak quality evaluation, we analyzed and compared six metrics: sharpness, Gaussian similarity, signal-to-noise ratio, peak significance level, triangle peak area similarity ratio and the local peak-related local zigzag index. Although the MCQ index is suited for selecting and aligning analyte components, it cannot fairly evaluate EICs with high background signals or those containing only a single peak. Our proposed EIC related global zigzag index is robust enough to evaluate EIC qualities in both scenarios. Of the six peak quality evaluation metrics, the sharpness, peak significance level, and zigzag index outperform the others due to the zigzag nature of LC/MS chromatographic peaks. Furthermore, using several peak quality metrics in combination is more efficient than individual metrics in peak quality evaluation.

  8. Development of quality metrics for ambulatory pediatric cardiology: Infection prevention.

    PubMed

    Johnson, Jonathan N; Barrett, Cindy S; Franklin, Wayne H; Graham, Eric M; Halnon, Nancy J; Hattendorf, Brandy A; Krawczeski, Catherine D; McGovern, James J; O'Connor, Matthew J; Schultz, Amy H; Vinocur, Jeffrey M; Chowdhury, Devyani; Anderson, Jeffrey B

    2017-12-01

    In 2012, the American College of Cardiology's (ACC) Adult Congenital and Pediatric Cardiology Council established a program to develop quality metrics to guide ambulatory practices for pediatric cardiology. The council chose five areas on which to focus their efforts; chest pain, Kawasaki Disease, tetralogy of Fallot, transposition of the great arteries after arterial switch, and infection prevention. Here, we sought to describe the process, evaluation, and results of the Infection Prevention Committee's metric design process. The infection prevention metrics team consisted of 12 members from 11 institutions in North America. The group agreed to work on specific infection prevention topics including antibiotic prophylaxis for endocarditis, rheumatic fever, and asplenia/hyposplenism; influenza vaccination and respiratory syncytial virus prophylaxis (palivizumab); preoperative methods to reduce intraoperative infections; vaccinations after cardiopulmonary bypass; hand hygiene; and testing to identify splenic function in patients with heterotaxy. An extensive literature review was performed. When available, previously published guidelines were used fully in determining metrics. The committee chose eight metrics to submit to the ACC Quality Metric Expert Panel for review. Ultimately, metrics regarding hand hygiene and influenza vaccination recommendation for patients did not pass the RAND analysis. Both endocarditis prophylaxis metrics and the RSV/palivizumab metric passed the RAND analysis but fell out during the open comment period. Three metrics passed all analyses, including those for antibiotic prophylaxis in patients with heterotaxy/asplenia, for influenza vaccination compliance in healthcare personnel, and for adherence to recommended regimens of secondary prevention of rheumatic fever. The lack of convincing data to guide quality improvement initiatives in pediatric cardiology is widespread, particularly in infection prevention. Despite this, three metrics were able to be developed for use in the ACC's quality efforts for ambulatory practice. © 2017 Wiley Periodicals, Inc.

  9. Quality Measurements in Radiology: A Systematic Review of the Literature and Survey of Radiology Benefit Management Groups.

    PubMed

    Narayan, Anand; Cinelli, Christina; Carrino, John A; Nagy, Paul; Coresh, Josef; Riese, Victoria G; Durand, Daniel J

    2015-11-01

    As the US health care system transitions toward value-based reimbursement, there is an increasing need for metrics to quantify health care quality. Within radiology, many quality metrics are in use, and still more have been proposed, but there have been limited attempts to systematically inventory these measures and classify them using a standard framework. The purpose of this study was to develop an exhaustive inventory of public and private sector imaging quality metrics classified according to the classic Donabedian framework (structure, process, and outcome). A systematic review was performed in which eligibility criteria included published articles (from 2000 onward) from multiple databases. Studies were double-read, with discrepancies resolved by consensus. For the radiology benefit management group (RBM) survey, the six known companies nationally were surveyed. Outcome measures were organized on the basis of standard categories (structure, process, and outcome) and reported using Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The search strategy yielded 1,816 citations; review yielded 110 reports (29 included for final analysis). Three of six RBMs (50%) responded to the survey; the websites of the other RBMs were searched for additional metrics. Seventy-five unique metrics were reported: 35 structure (46%), 20 outcome (27%), and 20 process (27%) metrics. For RBMs, 35 metrics were reported: 27 structure (77%), 4 process (11%), and 4 outcome (11%) metrics. The most commonly cited structure, process, and outcome metrics included ACR accreditation (37%), ACR Appropriateness Criteria (85%), and peer review (95%), respectively. Imaging quality metrics are more likely to be structural (46%) than process (27%) or outcome (27%) based (P < .05). As national value-based reimbursement programs increasingly emphasize outcome-based metrics, radiologists must keep pace by developing the data infrastructure required to collect outcome-based quality metrics. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  10. Evaluating which plan quality metrics are appropriate for use in lung SBRT.

    PubMed

    Yaparpalvi, Ravindra; Garg, Madhur K; Shen, Jin; Bodner, William R; Mynampati, Dinesh K; Gafar, Aleiya; Kuo, Hsiang-Chi; Basavatia, Amar K; Ohri, Nitin; Hong, Linda X; Kalnicki, Shalom; Tome, Wolfgang A

    2018-02-01

    Several dose metrics in the categories-homogeneity, coverage, conformity and gradient have been proposed in literature for evaluating treatment plan quality. In this study, we applied these metrics to characterize and identify the plan quality metrics that would merit plan quality assessment in lung stereotactic body radiation therapy (SBRT) dose distributions. Treatment plans of 90 lung SBRT patients, comprising 91 targets, treated in our institution were retrospectively reviewed. Dose calculations were performed using anisotropic analytical algorithm (AAA) with heterogeneity correction. A literature review on published plan quality metrics in the categories-coverage, homogeneity, conformity and gradient was performed. For each patient, using dose-volume histogram data, plan quality metric values were quantified and analysed. For the study, the radiation therapy oncology group (RTOG) defined plan quality metrics were: coverage (0.90 ± 0.08); homogeneity (1.27 ± 0.07); conformity (1.03 ± 0.07) and gradient (4.40 ± 0.80). Geometric conformity strongly correlated with conformity index (p < 0.0001). Gradient measures strongly correlated with target volume (p < 0.0001). The RTOG lung SBRT protocol advocated conformity guidelines for prescribed dose in all categories were met in ≥94% of cases. The proportion of total lung volume receiving doses of 20 Gy and 5 Gy (V 20 and V 5 ) were mean 4.8% (±3.2) and 16.4% (±9.2), respectively. Based on our study analyses, we recommend the following metrics as appropriate surrogates for establishing SBRT lung plan quality guidelines-coverage % (ICRU 62), conformity (CN or CI Paddick ) and gradient (R 50% ). Furthermore, we strongly recommend that RTOG lung SBRT protocols adopt either CN or CI Padddick in place of prescription isodose to target volume ratio for conformity index evaluation. Advances in knowledge: Our study metrics are valuable tools for establishing lung SBRT plan quality guidelines.

  11. Implementing Software Safety in the NASA Environment

    NASA Technical Reports Server (NTRS)

    Wetherholt, Martha S.; Radley, Charles F.

    1994-01-01

    Until recently, NASA did not consider allowing computers total control of flight systems. Human operators, via hardware, have constituted the ultimate safety control. In an attempt to reduce costs, NASA has come to rely more and more heavily on computers and software to control space missions. (For example. software is now planned to control most of the operational functions of the International Space Station.) Thus the need for systematic software safety programs has become crucial for mission success. Concurrent engineering principles dictate that safety should be designed into software up front, not tested into the software after the fact. 'Cost of Quality' studies have statistics and metrics to prove the value of building quality and safety into the development cycle. Unfortunately, most software engineers are not familiar with designing for safety, and most safety engineers are not software experts. Software written to specifications which have not been safety analyzed is a major source of computer related accidents. Safer software is achieved step by step throughout the system and software life cycle. It is a process that includes requirements definition, hazard analyses, formal software inspections, safety analyses, testing, and maintenance. The greatest emphasis is placed on clearly and completely defining system and software requirements, including safety and reliability requirements. Unfortunately, development and review of requirements are the weakest link in the process. While some of the more academic methods, e.g. mathematical models, may help bring about safer software, this paper proposes the use of currently approved software methodologies, and sound software and assurance practices to show how, to a large degree, safety can be designed into software from the start. NASA's approach today is to first conduct a preliminary system hazard analysis (PHA) during the concept and planning phase of a project. This determines the overall hazard potential of the system to be built. Shortly thereafter, as the system requirements are being defined, the second iteration of hazard analyses takes place, the systems hazard analysis (SHA). During the systems requirements phase, decisions are made as to what functions of the system will be the responsibility of software. This is the most critical time to affect the safety of the software. From this point, software safety analyses as well as software engineering practices are the main focus for assuring safe software. While many of the steps proposed in this paper seem like just sound engineering practices, they are the best technical and most cost effective means to assure safe software within a safe system.

  12. Enhancing User Customization through Novel Software Architecture for Utility Scale Solar Siting Software

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brant Peery; Sam Alessi; Randy Lee

    2014-06-01

    There is a need for a spatial decision support application that allows users to create customized metrics for comparing proposed locations of a new solar installation. This document discusses how PVMapper was designed to overcome the customization problem through the development of loosely coupled spatial and decision components in a JavaScript plugin architecture. This allows the user to easily add functionality and data to the system. The paper also explains how PVMapper provides the user with a dynamic and customizable decision tool that enables them to visually modify the formulas that are used in the decision algorithms that convert datamore » to comparable metrics. The technologies that make up the presentation and calculation software stack are outlined. This document also explains the architecture that allows the tool to grow through custom plugins created by the software users. Some discussion is given on the difficulties encountered while designing the system.« less

  13. Software Management Metrics

    DTIC Science & Technology

    1988-05-01

    obtained from Dr. Barry Boehm’s Software 5650, Contract No. F19628-86-C-O001, Engineering Economics [1] and from T. J. ESD/MITRE Software Center Acquisition...of References 1. Boehm, Barry W., SoJtware Engineering 3. Halstead, M. H., Elements of SoJhtare Economics, Englewood Cliffs, New Science, New York...1983, pp. 639-648. 35 35 - Bibliography Beizer, B., Software System Testing and Pressman , Roger S., Software Engineering:QualtyO Assurance, New York: Van

  14. Colonoscopy Quality: Metrics and Implementation

    PubMed Central

    Calderwood, Audrey H.; Jacobson, Brian C.

    2013-01-01

    Synopsis Colonoscopy is an excellent area for quality improvement 1 because it is high volume, has significant associated risk and expense, and there is evidence that variability in its performance affects outcomes. The best endpoint for validation of quality metrics in colonoscopy is colorectal cancer incidence and mortality, but because of feasibility issues, a more readily accessible metric is the adenoma detection rate (ADR). Fourteen quality metrics were proposed by the joint American Society of Gastrointestinal Endoscopy/American College of Gastroenterology Task Force on “Quality Indicators for Colonoscopy” in 2006, which are described in further detail below. Use of electronic health records and quality-oriented registries will facilitate quality measurement and reporting. Unlike traditional clinical research, implementation of quality improvement initiatives involves rapid assessments and changes on an iterative basis, and can be done at the individual, group, or facility level. PMID:23931862

  15. Software Reporting Metrics. Revision 2.

    DTIC Science & Technology

    1985-11-01

    MITRE Corporation and ESD. Some of the data has been obtained from Dr. Barry Boehm’s Software Engineering Economics (Ref. 1). Thanks are also given to...data level control management " SP = structured programming Barry W. Boehm, Software Engineering Economics, &©1981, p. 122. Reprinted by permission of...investigated and implemented in future prototypes. 43 REFERENCES For further reading: " 1. Boehm, Barry W. Software Engineering Economics; Englewood

  16. Four applications of a software data collection and analysis methodology

    NASA Technical Reports Server (NTRS)

    Basili, Victor R.; Selby, Richard W., Jr.

    1985-01-01

    The evaluation of software technologies suffers because of the lack of quantitative assessment of their effect on software development and modification. A seven-step data collection and analysis methodology couples software technology evaluation with software measurement. Four in-depth applications of the methodology are presented. The four studies represent each of the general categories of analyses on the software product and development process: blocked subject-project studies, replicated project studies, multi-project variation studies, and single project strategies. The four applications are in the areas of, respectively, software testing, cleanroom software development, characteristic software metric sets, and software error analysis.

  17. MO-A-16A-01: QA Procedures and Metrics: In Search of QA Usability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sathiaseelan, V; Thomadsen, B

    Radiation therapy has undergone considerable changes in the past two decades with a surge of new technology and treatment delivery methods. The complexity of radiation therapy treatments has increased and there has been increased awareness and publicity about the associated risks. In response, there has been proliferation of guidelines for medical physicists to adopt to ensure that treatments are delivered safely. Task Group recommendations are copious, and clinical physicists' hours are longer, stretched to various degrees between site planning and management, IT support, physics QA, and treatment planning responsibilities.Radiation oncology has many quality control practices in place to ensure themore » delivery of high-quality, safe treatments. Incident reporting systems have been developed to collect statistics about near miss events at many radiation oncology centers. However, tools are lacking to assess the impact of these various control measures. A recent effort to address this shortcoming is the work of Ford et al (2012) who recently published a methodology enumerating quality control quantification for measuring the effectiveness of safety barriers. Over 4000 near-miss incidents reported from 2 academic radiation oncology clinics were analyzed using quality control quantification, and a profile of the most effective quality control measures (metrics) was identified.There is a critical need to identify a QA metric to help the busy clinical physicists to focus their limited time and resources most effectively in order to minimize or eliminate errors in the radiation treatment delivery processes. In this symposium the usefulness of workflows and QA metrics to assure safe and high quality patient care will be explored.Two presentations will be given:Quality Metrics and Risk Management with High Risk Radiation Oncology ProceduresStrategies and metrics for quality management in the TG-100 Era Learning Objectives: Provide an overview and the need for QA usability metrics: Different cultures/practices affecting the effectiveness of methods and metrics. Show examples of quality assurance workflows, Statistical process control, that monitor the treatment planning and delivery process to identify errors. To learn to identify and prioritize risks and QA procedures in radiation oncology. Try to answer the question: Can a quality assurance program aided by quality assurance metrics help minimize errors and ensure safe treatment delivery. Should such metrics be institution specific.« less

  18. The data quality analyzer: a quality control program for seismic data

    USGS Publications Warehouse

    Ringler, Adam; Hagerty, M.T.; Holland, James F.; Gonzales, A.; Gee, Lind S.; Edwards, J.D.; Wilson, David; Baker, Adam

    2015-01-01

    The quantification of data quality is based on the evaluation of various metrics (e.g., timing quality, daily noise levels relative to long-term noise models, and comparisons between broadband data and event synthetics). Users may select which metrics contribute to the assessment and those metrics are aggregated into a “grade” for each station. The DQA is being actively used for station diagnostics and evaluation based on the completed metrics (availability, gap count, timing quality, deviation from a global noise model, deviation from a station noise model, coherence between co-located sensors, and comparison between broadband data and synthetics for earthquakes) on stations in the Global Seismographic Network and Advanced National Seismic System.

  19. A condition metric for Eucalyptus woodland derived from expert evaluations.

    PubMed

    Sinclair, Steve J; Bruce, Matthew J; Griffioen, Peter; Dodd, Amanda; White, Matthew D

    2018-02-01

    The evaluation of ecosystem quality is important for land-management and land-use planning. Evaluation is unavoidably subjective, and robust metrics must be based on consensus and the structured use of observations. We devised a transparent and repeatable process for building and testing ecosystem metrics based on expert data. We gathered quantitative evaluation data on the quality of hypothetical grassy woodland sites from experts. We used these data to train a model (an ensemble of 30 bagged regression trees) capable of predicting the perceived quality of similar hypothetical woodlands based on a set of 13 site variables as inputs (e.g., cover of shrubs, richness of native forbs). These variables can be measured at any site and the model implemented in a spreadsheet as a metric of woodland quality. We also investigated the number of experts required to produce an opinion data set sufficient for the construction of a metric. The model produced evaluations similar to those provided by experts, as shown by assessing the model's quality scores of expert-evaluated test sites not used to train the model. We applied the metric to 13 woodland conservation reserves and asked managers of these sites to independently evaluate their quality. To assess metric performance, we compared the model's evaluation of site quality with the managers' evaluations through multidimensional scaling. The metric performed relatively well, plotting close to the center of the space defined by the evaluators. Given the method provides data-driven consensus and repeatability, which no single human evaluator can provide, we suggest it is a valuable tool for evaluating ecosystem quality in real-world contexts. We believe our approach is applicable to any ecosystem. © 2017 State of Victoria.

  20. Geographic techniques and recent applications of remote sensing to landscape-water quality studies

    USGS Publications Warehouse

    Griffith, J.A.

    2002-01-01

    This article overviews recent advances in studies of landscape-water quality relationships using remote sensing techniques. With the increasing feasibility of using remotely-sensed data, landscape-water quality studies can now be more easily performed on regional, multi-state scales. The traditional method of relating land use and land cover to water quality has been extended to include landscape pattern and other landscape information derived from satellite data. Three items are focused on in this article: 1) the increasing recognition of the importance of larger-scale studies of regional water quality that require a landscape perspective; 2) the increasing importance of remotely sensed data, such as the imagery-derived normalized difference vegetation index (NDVI) and vegetation phenological metrics derived from time-series NDVI data; and 3) landscape pattern. In some studies, using landscape pattern metrics explained some of the variation in water quality not explained by land use/cover. However, in some other studies, the NDVI metrics were even more highly correlated to certain water quality parameters than either landscape pattern metrics or land use/cover proportions. Although studies relating landscape pattern metrics to water quality have had mixed results, this recent body of work applying these landscape measures and satellite-derived metrics to water quality analysis has demonstrated their potential usefulness in monitoring watershed conditions across large regions.

  1. Test Methods for Robot Agility in Manufacturing.

    PubMed

    Downs, Anthony; Harrison, William; Schlenoff, Craig

    2016-01-01

    The paper aims to define and describe test methods and metrics to assess industrial robot system agility in both simulation and in reality. The paper describes test methods and associated quantitative and qualitative metrics for assessing robot system efficiency and effectiveness which can then be used for the assessment of system agility. The paper describes how the test methods were implemented in a simulation environment and real world environment. It also shows how the metrics are measured and assessed as they would be in a future competition. The test methods described in this paper will push forward the state of the art in software agility for manufacturing robots, allowing small and medium manufacturers to better utilize robotic systems. The paper fulfills the identified need for standard test methods to measure and allow for improvement in software agility for manufacturing robots.

  2. The Albuquerque Seismological Laboratory Data Quality Analyzer

    NASA Astrophysics Data System (ADS)

    Ringler, A. T.; Hagerty, M.; Holland, J.; Gee, L. S.; Wilson, D.

    2013-12-01

    The U.S. Geological Survey's Albuquerque Seismological Laboratory (ASL) has several efforts underway to improve data quality at its stations. The Data Quality Analyzer (DQA) is one such development. The DQA is designed to characterize station data quality in a quantitative and automated manner. Station quality is based on the evaluation of various metrics, such as timing quality, noise levels, sensor coherence, and so on. These metrics are aggregated into a measurable grade for each station. The DQA consists of a website, a metric calculator (Seedscan), and a PostgreSQL database. The website allows the user to make requests for various time periods, review specific networks and stations, adjust weighting of the station's grade, and plot metrics as a function of time. The website dynamically loads all station data from a PostgreSQL database. The database is central to the application; it acts as a hub where metric values and limited station descriptions are stored. Data is stored at the level of one sensor's channel per day. The database is populated by Seedscan. Seedscan reads and processes miniSEED data, to generate metric values. Seedscan, written in Java, compares hashes of metadata and data to detect changes and perform subsequent recalculations. This ensures that the metric values are up to date and accurate. Seedscan can be run in a scheduled task or on demand by way of a config file. It will compute metrics specified in its configuration file. While many metrics are currently in development, some are completed and being actively used. These include: availability, timing quality, gap count, deviation from the New Low Noise Model, deviation from a station's noise baseline, inter-sensor coherence, and data-synthetic fits. In all, 20 metrics are planned, but any number could be added. ASL is actively using the DQA on a daily basis for station diagnostics and evaluation. As Seedscan is scheduled to run every night, data quality analysts are able to then use the website to diagnose changes in noise levels or other anomalous data. This allows for errors to be corrected quickly and efficiently. The code is designed to be flexible for adding metrics and portable for use in other networks. We anticipate further development of the DQA by improving the existing web-interface, adding more metrics, adding an interface to facilitate the verification of historic station metadata and performance, and an interface to allow better monitoring of data quality goals.

  3. Improving the Effectiveness of Program Managers

    DTIC Science & Technology

    2006-05-03

    Improving the Effectiveness of Program Managers Systems and Software Technology Conference Salt Lake City, Utah May 3, 2006 Presented by GAO’s...Companies’ best practices Motorola Caterpillar Toyota FedEx NCR Teradata Boeing Hughes Space and Communications Disciplined software and management...and total ownership costs Collection of metrics data to improve software reliability Technology readiness levels and design maturity Statistical

  4. Perceived assessment metrics for visible and infrared color fused image quality without reference image

    NASA Astrophysics Data System (ADS)

    Yu, Xuelian; Chen, Qian; Gu, Guohua; Ren, Jianle; Sui, Xiubao

    2015-02-01

    Designing objective quality assessment of color-fused image is a very demanding and challenging task. We propose four no-reference metrics based on human visual system characteristics for objectively evaluating the quality of false color fusion image. The perceived edge metric (PEM) is defined based on visual perception model and color image gradient similarity between the fused image and the source images. The perceptual contrast metric (PCM) is established associating multi-scale contrast and varying contrast sensitivity filter (CSF) with color components. The linear combination of the standard deviation and mean value over the fused image construct the image colorfulness metric (ICM). The color comfort metric (CCM) is designed by the average saturation and the ratio of pixels with high and low saturation. The qualitative and quantitative experimental results demonstrate that the proposed metrics have a good agreement with subjective perception.

  5. Image Correlation Pattern Optimization for Micro-Scale In-Situ Strain Measurements

    NASA Technical Reports Server (NTRS)

    Bomarito, G. F.; Hochhalter, J. D.; Cannon, A. H.

    2016-01-01

    The accuracy and precision of digital image correlation (DIC) is a function of three primary ingredients: image acquisition, image analysis, and the subject of the image. Development of the first two (i.e. image acquisition techniques and image correlation algorithms) has led to widespread use of DIC; however, fewer developments have been focused on the third ingredient. Typically, subjects of DIC images are mechanical specimens with either a natural surface pattern or a pattern applied to the surface. Research in the area of DIC patterns has primarily been aimed at identifying which surface patterns are best suited for DIC, by comparing patterns to each other. Because the easiest and most widespread methods of applying patterns have a high degree of randomness associated with them (e.g., airbrush, spray paint, particle decoration, etc.), less effort has been spent on exact construction of ideal patterns. With the development of patterning techniques such as microstamping and lithography, patterns can be applied to a specimen pixel by pixel from a patterned image. In these cases, especially because the patterns are reused many times, an optimal pattern is sought such that error introduced into DIC from the pattern is minimized. DIC consists of tracking the motion of an array of nodes from a reference image to a deformed image. Every pixel in the images has an associated intensity (grayscale) value, with discretization depending on the bit depth of the image. Because individual pixel matching by intensity value yields a non-unique scale-dependent problem, subsets around each node are used for identification. A correlation criteria is used to find the best match of a particular subset of a reference image within a deformed image. The reader is referred to references for enumerations of typical correlation criteria. As illustrated by Schreier and Sutton and Lu and Cary systematic errors can be introduced by representing the underlying deformation with under-matched shape functions. An important implication, as discussed by Sutton et al., is that in the presence of highly localized deformations (e.g., crack fronts), error can be reduced by minimizing the subset size. In other words, smaller subsets allow the more accurate resolution of localized deformations. Contrarily, the choice of optimal subset size has been widely studied and a general consensus is that larger subsets with more information content are less prone to random error. Thus, an optimal subset size balances the systematic error from under matched deformations with random error from measurement noise. The alternative approach pursued in the current work is to choose a small subset size and optimize the information content within (i.e., optimizing an applied DIC pattern), rather than finding an optimal subset size. In the literature, many pattern quality metrics have been proposed, e.g., sum of square intensity gradient (SSSIG), mean subset fluctuation, gray level co-occurrence, autocorrelation-based metrics, and speckle-based metrics. The majority of these metrics were developed to quantify the quality of common pseudo-random patterns after they have been applied, and were not created with the intent of pattern generation. As such, it is found that none of the metrics examined in this study are fit to be the objective function of a pattern generation optimization. In some cases, such as with speckle-based metrics, application to pixel by pixel patterns is ill-conditioned and requires somewhat arbitrary extensions. In other cases, such as with the SSSIG, it is shown that trivial solutions exist for the optimum of the metric which are ill-suited for DIC (such as a checkerboard pattern). In the current work, a multi-metric optimization method is proposed whereby quality is viewed as a combination of individual quality metrics. Specifically, SSSIG and two auto-correlation metrics are used which have generally competitive objectives. Thus, each metric could be viewed as a constraint imposed upon the others, thereby precluding the achievement of their trivial solutions. In this way, optimization produces a pattern which balances the benefits of multiple quality metrics. The resulting pattern, along with randomly generated patterns, is subjected to numerical deformations and analyzed with DIC software. The optimal pattern is shown to outperform randomly generated patterns.

  6. Degraded visual environment image/video quality metrics

    NASA Astrophysics Data System (ADS)

    Baumgartner, Dustin D.; Brown, Jeremy B.; Jacobs, Eddie L.; Schachter, Bruce J.

    2014-06-01

    A number of image quality metrics (IQMs) and video quality metrics (VQMs) have been proposed in the literature for evaluating techniques and systems for mitigating degraded visual environments. Some require both pristine and corrupted imagery. Others require patterned target boards in the scene. None of these metrics relates well to the task of landing a helicopter in conditions such as a brownout dust cloud. We have developed and used a variety of IQMs and VQMs related to the pilot's ability to detect hazards in the scene and to maintain situational awareness. Some of these metrics can be made agnostic to sensor type. Not only are the metrics suitable for evaluating algorithm and sensor variation, they are also suitable for choosing the most cost effective solution to improve operating conditions in degraded visual environments.

  7. Applying Sigma Metrics to Reduce Outliers.

    PubMed

    Litten, Joseph

    2017-03-01

    Sigma metrics can be used to predict assay quality, allowing easy comparison of instrument quality and predicting which tests will require minimal quality control (QC) rules to monitor the performance of the method. A Six Sigma QC program can result in fewer controls and fewer QC failures for methods with a sigma metric of 5 or better. The higher the number of methods with a sigma metric of 5 or better, the lower the costs for reagents, supplies, and control material required to monitor the performance of the methods. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Quality Measures in Stroke

    PubMed Central

    Poisson, Sharon N.; Josephson, S. Andrew

    2011-01-01

    Stroke is a major public health burden, and accounts for many hospitalizations each year. Due to gaps in practice and recommended guidelines, there has been a recent push toward implementing quality measures to be used for improving patient care, comparing institutions, as well as for rewarding or penalizing physicians through pay-for-performance. This article reviews the major organizations involved in implementing quality metrics for stroke, and the 10 major metrics currently being tracked. We also discuss possible future metrics and the implications of public reporting and using metrics for pay-for-performance. PMID:23983840

  9. National evaluation of multidisciplinary quality metrics for head and neck cancer.

    PubMed

    Cramer, John D; Speedy, Sedona E; Ferris, Robert L; Rademaker, Alfred W; Patel, Urjeet A; Samant, Sandeep

    2017-11-15

    The National Quality Forum has endorsed quality-improvement measures for multiple cancer types that are being developed into actionable tools to improve cancer care. No nationally endorsed quality metrics currently exist for head and neck cancer. The authors identified patients with surgically treated, invasive, head and neck squamous cell carcinoma in the National Cancer Data Base from 2004 to 2014 and compared the rate of adherence to 5 different quality metrics and whether compliance with these quality metrics impacted overall survival. The metrics examined included negative surgical margins, neck dissection lymph node (LN) yield ≥ 18, appropriate adjuvant radiation, appropriate adjuvant chemoradiation, adjuvant therapy within 6 weeks, as well as overall quality. In total, 76,853 eligible patients were identified. There was substantial variability in patient-level adherence, which was 80% for negative surgical margins, 73.1% for neck dissection LN yield, 69% for adjuvant radiation, 42.6% for adjuvant chemoradiation, and 44.5% for adjuvant therapy within 6 weeks. Risk-adjusted Cox proportional-hazard models indicated that all metrics were associated with a reduced risk of death: negative margins (hazard ratio [HR] 0.73; 95% confidence interval [CI], 0.71-0.76), LN yield ≥ 18 (HR, 0.93; 95% CI, 0.89-0.96), adjuvant radiation (HR, 0.67; 95% CI, 0.64-0.70), adjuvant chemoradiation (HR, 0.84; 95% CI, 0.79-0.88), and adjuvant therapy ≤6 weeks (HR, 0.92; 95% CI, 0.89-0.96). Patients who received high-quality care had a 19% reduced adjusted hazard of mortality (HR, 0.81; 95% CI, 0.79-0.83). Five head and neck cancer quality metrics were identified that have substantial variability in adherence and meaningfully impact overall survival. These metrics are appropriate candidates for national adoption. Cancer 2017;123:4372-81. © 2017 American Cancer Society. © 2017 American Cancer Society.

  10. An exploratory survey of methods used to develop measures of performance

    NASA Astrophysics Data System (ADS)

    Hamner, Kenneth L.; Lafleur, Charles A.

    1993-09-01

    Nonmanufacturing organizations are being challenged to provide high-quality products and services to their customers, with an emphasis on continuous process improvement. Measures of performance, referred to as metrics, can be used to foster process improvement. The application of performance measurement to nonmanufacturing processes can be very difficult. This research explored methods used to develop metrics in nonmanufacturing organizations. Several methods were formally defined in the literature, and the researchers used a two-step screening process to determine the OMB Generic Method was most likely to produce high-quality metrics. The OMB Generic Method was then used to develop metrics. A few other metric development methods were found in use at nonmanufacturing organizations. The researchers interviewed participants in metric development efforts to determine their satisfaction and to have them identify the strengths and weaknesses of, and recommended improvements to, the metric development methods used. Analysis of participants' responses allowed the researchers to identify the key components of a sound metrics development method. Those components were incorporated into a proposed metric development method that was based on the OMB Generic Method, and should be more likely to produce high-quality metrics that will result in continuous process improvement.

  11. Quality control, analysis and secure sharing of Luminex® immunoassay data using the open source LabKey Server platform

    PubMed Central

    2013-01-01

    Background Immunoassays that employ multiplexed bead arrays produce high information content per sample. Such assays are now frequently used to evaluate humoral responses in clinical trials. Integrated software is needed for the analysis, quality control, and secure sharing of the high volume of data produced by such multiplexed assays. Software that facilitates data exchange and provides flexibility to perform customized analyses (including multiple curve fits and visualizations of assay performance over time) could increase scientists’ capacity to use these immunoassays to evaluate human clinical trials. Results The HIV Vaccine Trials Network and the Statistical Center for HIV/AIDS Research and Prevention collaborated with LabKey Software to enhance the open source LabKey Server platform to facilitate workflows for multiplexed bead assays. This system now supports the management, analysis, quality control, and secure sharing of data from multiplexed immunoassays that leverage Luminex xMAP® technology. These assays may be custom or kit-based. Newly added features enable labs to: (i) import run data from spreadsheets output by Bio-Plex Manager™ software; (ii) customize data processing, curve fits, and algorithms through scripts written in common languages, such as R; (iii) select script-defined calculation options through a graphical user interface; (iv) collect custom metadata for each titration, analyte, run and batch of runs; (v) calculate dose–response curves for titrations; (vi) interpolate unknown concentrations from curves for titrated standards; (vii) flag run data for exclusion from analysis; (viii) track quality control metrics across runs using Levey-Jennings plots; and (ix) automatically flag outliers based on expected values. Existing system features allow researchers to analyze, integrate, visualize, export and securely share their data, as well as to construct custom user interfaces and workflows. Conclusions Unlike other tools tailored for Luminex immunoassays, LabKey Server allows labs to customize their Luminex analyses using scripting while still presenting users with a single, graphical interface for processing and analyzing data. The LabKey Server system also stands out among Luminex tools for enabling smooth, secure transfer of data, quality control information, and analyses between collaborators. LabKey Server and its Luminex features are freely available as open source software at http://www.labkey.com under the Apache 2.0 license. PMID:23631706

  12. Quality control, analysis and secure sharing of Luminex® immunoassay data using the open source LabKey Server platform.

    PubMed

    Eckels, Josh; Nathe, Cory; Nelson, Elizabeth K; Shoemaker, Sara G; Nostrand, Elizabeth Van; Yates, Nicole L; Ashley, Vicki C; Harris, Linda J; Bollenbeck, Mark; Fong, Youyi; Tomaras, Georgia D; Piehler, Britt

    2013-04-30

    Immunoassays that employ multiplexed bead arrays produce high information content per sample. Such assays are now frequently used to evaluate humoral responses in clinical trials. Integrated software is needed for the analysis, quality control, and secure sharing of the high volume of data produced by such multiplexed assays. Software that facilitates data exchange and provides flexibility to perform customized analyses (including multiple curve fits and visualizations of assay performance over time) could increase scientists' capacity to use these immunoassays to evaluate human clinical trials. The HIV Vaccine Trials Network and the Statistical Center for HIV/AIDS Research and Prevention collaborated with LabKey Software to enhance the open source LabKey Server platform to facilitate workflows for multiplexed bead assays. This system now supports the management, analysis, quality control, and secure sharing of data from multiplexed immunoassays that leverage Luminex xMAP® technology. These assays may be custom or kit-based. Newly added features enable labs to: (i) import run data from spreadsheets output by Bio-Plex Manager™ software; (ii) customize data processing, curve fits, and algorithms through scripts written in common languages, such as R; (iii) select script-defined calculation options through a graphical user interface; (iv) collect custom metadata for each titration, analyte, run and batch of runs; (v) calculate dose-response curves for titrations; (vi) interpolate unknown concentrations from curves for titrated standards; (vii) flag run data for exclusion from analysis; (viii) track quality control metrics across runs using Levey-Jennings plots; and (ix) automatically flag outliers based on expected values. Existing system features allow researchers to analyze, integrate, visualize, export and securely share their data, as well as to construct custom user interfaces and workflows. Unlike other tools tailored for Luminex immunoassays, LabKey Server allows labs to customize their Luminex analyses using scripting while still presenting users with a single, graphical interface for processing and analyzing data. The LabKey Server system also stands out among Luminex tools for enabling smooth, secure transfer of data, quality control information, and analyses between collaborators. LabKey Server and its Luminex features are freely available as open source software at http://www.labkey.com under the Apache 2.0 license.

  13. Felyx : A Free Open Software Solution for the Analysis of Large Earth Observation Datasets

    NASA Astrophysics Data System (ADS)

    Piolle, Jean-Francois; Shutler, Jamie; Poulter, David; Guidetti, Veronica; Donlon, Craig

    2014-05-01

    GHRSST project, by assembling large collections of earth observation data from various sources and agencies, has also raised the need for providing the user community with tools to inter-compare them, assess and monitor their quality. The ESA /Medspiration project, which implemented the first operating node of GHRSST system for Europe, also paved the way successfully towards such generic analytics tools by developing the High Resolution Diagnostic Dataset System (HR-DDS) and Satellite to In situ Multi-sensor Match-up Databases. Building on this heritage, ESA is now funding the development by IFREMER, PML and Pelamis of felyx, a web tool merging the two capabilities into a single software solution. It will consist in a free open software solution, written in python and javascript, whose aim is to provide Earth Observation data producers and users with an open-source, flexible and reusable tool to allow the quality and performance of data streams (satellite, in situ and model) to be easily monitored and studied. The primary concept of Felyx is to work as an extraction tool, subsetting source data over predefined target areas (which can be static or moving) : these data subsets, and associated metrics, can then be accessed by users or client applications either as raw files, automatic alerts and reports generated periodically, or through a flexible web interface enabling statistical analysis and visualization. Felyx presents itself as an open-source suite of tools, written in python and javascript, enabling : * subsetting large local or remote collections of Earth Observation data over predefined sites (geographical boxes) or moving targets (ship, buoy, hurricane), storing locally the extracted data (refered as miniProds). These miniProds constitute a much smaller representative subset of the original collection on which one can perform any kind of processing or assessment without having to cope with heavy volumes of data. * computing statistical metrics over these miniProds using for instance a set of usual statistical operators (mean, median, rms, ...), fully extensible and applicable to any variable of a dataset. These metrics are stored in a fast search engine, queryable by humans and automated applications. * reporting or alerting, based on user-defined inference rules, through various media (emails, twitter feeds,..) and devices (phones, tablets). * analysing miniProds and metrics through a web interface allowing to dig into this base of information and extracting useful knowledge through multidimensional interactive display functions (time series, scatterplots, histograms, maps). The services provided by felyx will be generic, deployable at users own premises and adaptable enough to integrate any kind of parameters. Users will be able to operate their own felyx instance at any location, on datasets and parameters of their own interest, and the various instances will be able to interact with each other, creating a web of felyx systems enabling aggregation and cross comparison of miniProds and metrics from multiple sources. Initially two instances will be operated simultaneously during a 6 months demonstration phase, at IFREMER - on sea surface temperature (for GHRSST community) and ocean waves datasets - and PML - on ocean colour. We will present results from the Felyx project, demonstrate how the GHRSST community can exploit Felyx and demonstrate how the wider community can make use of the GHRSST data within Felyx.

  14. Macroinvertebrate and diatom metrics as indicators of water-quality conditions in connected depression wetlands in the Mississippi Alluvial Plain

    USGS Publications Warehouse

    Justus, Billy; Burge, David; Cobb, Jennifer; Marsico, Travis; Bouldin, Jennifer

    2016-01-01

    Methods for assessing wetland conditions must be established so wetlands can be monitored and ecological services can be protected. We evaluated biological indices compiled from macroinvertebrate and diatom metrics developed primarily for streams to assess their ability to indicate water quality in connected depression wetlands. We collected water-quality and biological samples at 24 connected depressions dominated by water tupelo (Nyssa aquatica) or bald cypress (Taxodium distichum) (water depths = 0.5–1.0 m). Water quality of the least-disturbed connected depressions was characteristic of swamps in the southeastern USA, which tend to have low specific conductance, nutrient concentrations, and pH. We compared 162 macroinvertebrate metrics and 123 diatom metrics with a water-quality disturbance gradient. For most metrics, we evaluated richness, % richness, abundance, and % relative abundance values. Three of the 4 macroinvertebrate metrics that were most beneficial for identifying disturbance in connected depressions decreased along the disturbance gradient even though they normally increase relative to stream disturbance. The negative relationship to disturbance of some taxa (e.g., dipterans, mollusks, and crustaceans) that are considered tolerant in streams suggests that the tolerance scale for some macroinvertebrates can differ markedly between streams and wetlands. Three of the 4 metrics chosen for the diatom index reflected published tolerances or fit the usual perception of metric response to disturbance. Both biological indices may be useful in connected depressions elsewhere in the Mississippi Alluvial Plain Ecoregion and could have application in other wetland types. Given the paradoxical relationship of some macroinvertebrate metrics to dissolved O2 (DO), we suggest that the diatom metrics may be easier to interpret and defend for wetlands with low DO concentrations in least-disturbed conditions.

  15. Production of Reliable Flight Crucial Software: Validation Methods Research for Fault Tolerant Avionics and Control Systems Sub-Working Group Meeting

    NASA Technical Reports Server (NTRS)

    Dunham, J. R. (Editor); Knight, J. C. (Editor)

    1982-01-01

    The state of the art in the production of crucial software for flight control applications was addressed. The association between reliability metrics and software is considered. Thirteen software development projects are discussed. A short term need for research in the areas of tool development and software fault tolerance was indicated. For the long term, research in format verification or proof methods was recommended. Formal specification and software reliability modeling, were recommended as topics for both short and long term research.

  16. Field Validity of Heart Rate Variability Metrics Produced by QRSTool and CMetX

    ERIC Educational Resources Information Center

    Hibbert, Anita S.; Weinberg, Anna; Klonsky, E. David

    2012-01-01

    Interest in heart rate variability (HRV) metrics as markers of physiological and psychological health continues to grow beyond those with psychophysiological expertise, increasing the importance of developing suitable tools for researchers new to the field. Allen, Chambers, and Towers (2007) developed QRSTool and CMetX software as simple,…

  17. An Examination of Selected Software Testing Tools: 1992

    DTIC Science & Technology

    1992-12-01

    Report ....................................................... 27-19 Figure 27-17. Metrics Manager Database Full Report...historical test database , the test management and problem reporting tools were examined using the sample test database provided by each supplier. 4-4...track the impact of new methods, organi- zational structures, and technologies. Metrics Manager is supported by an industry database that allows

  18. Don't give an inch!

    NASA Astrophysics Data System (ADS)

    Geller, Robert J.

    The camera ready copy (CRC) procedures for Geophysical Research Letters are now being revised. As one of the new editors, I looked through preliminary versions of the new forms and instructions for authors. Remarkably, all of the units (for example, maximum length = 75 inches or 189.9 cm) are given in both British and metric units, despite the fact that AGU's style guide for authors (Eos, October 11, 1988) states that “all quantities must be in metric units.”When I contacted the AGU staff to ask them to eliminate the anachronistic British units they refused, claiming that “In the word-processing packages with which we are familiar all margins are given in inches. It is inconvenient for folks not to have both measurements if the software they are using for making CRC requires them to give commands in the British system.” They did not, however, cite any examples of a software package that will not also accept metric units, perhaps because none exists. All packages with which I am familiar accept both inches and metric units.

  19. Benchmarking the ATLAS software through the Kit Validation engine

    NASA Astrophysics Data System (ADS)

    De Salvo, Alessandro; Brasolin, Franco

    2010-04-01

    The measurement of the experiment software performance is a very important metric in order to choose the most effective resources to be used and to discover the bottlenecks of the code implementation. In this work we present the benchmark techniques used to measure the ATLAS software performance through the ATLAS offline testing engine Kit Validation and the online portal Global Kit Validation. The performance measurements, the data collection, the online analysis and display of the results will be presented. The results of the measurement on different platforms and architectures will be shown, giving a full report on the CPU power and memory consumption of the Monte Carlo generation, simulation, digitization and reconstruction of the most CPU-intensive channels. The impact of the multi-core computing on the ATLAS software performance will also be presented, comparing the behavior of different architectures when increasing the number of concurrent processes. The benchmark techniques described in this paper have been used in the HEPiX group since the beginning of 2008 to help defining the performance metrics for the High Energy Physics applications, based on the real experiment software.

  20. Future Software Sizing Metrics and Estimation Challenges

    DTIC Science & Technology

    2011-07-01

    systems 4. Ultrahigh software system assurance 5. Legacy maintenance and Brownfield development 6. Agile and Lean/ Kanban development. This paper...refined as the design of the maintenance modifications or Brownfield re-engineering is determined. VII. 6. AGILE AND LEAN/ KANBAN DEVELOPMENT The...difficulties of software maintenance estimation can often be mitigated by using lean workflow management techniques such as Kanban [25]. In Kanban

  1. Modular Filter and Source-Management Upgrade of RADAC

    NASA Technical Reports Server (NTRS)

    Lanzi, R. James; Smith, Donna C.

    2007-01-01

    In an upgrade of the Range Data Acquisition Computer (RADAC) software, a modular software object library was developed to implement required functionality for filtering of flight-vehicle-tracking data and management of tracking-data sources. (The RADAC software is used to process flight-vehicle metric data for realtime display in the Wallops Flight Facility Range Control Center and Mobile Control Center.)

  2. Comparison of two high-resolution manometry software systems in evaluating esophageal motor function.

    PubMed

    Rengarajan, A; Drapekin, J; Patel, A; Gyawali, C P

    2016-12-01

    High-resolution manometry (HRM) utilizes software tools to diagnose esophageal motor disorders. Performance of these software metrics could be affected by averaging and by software characteristics of different manufacturers. High-resolution manometry studies on 86 patients referred for antireflux surgery (61.6 ± 1.4 year, 70% F) and 20 healthy controls (27.9 ± 0.7 year, 45% F) were first subject to standard analysis (Medtronic, Duluth, GA, USA). Coordinates for each of 10 test swallows were exported and averaged to generate a composite swallow. The swallows and averaged composites were imported as ASCII file format into Manoview (Medtronic) and Medical Measurement Systems database reporter (MMS, Dover, NH, USA), and analyses repeated. Comparisons were made between standard and composite swallow interpretations. Correlation between the two systems was high for mean distal contractile integral (DCI, r 2 ≥ 0.9) but lower for integrated relaxation pressure (IRP, r 2 = 0.7). Excluding achalasia, six patients with outflow obstruction (mean IRP 23.2 ± 2.1 with 10-swallow average) were identified by both systems. An additional nine patients (10.5%) were identified as outflow obstruction (15 mmHg threshold) with MMS 10-swallow and four with MMS composite swallow evaluation; only one was confirmed. Ineffective esophageal motility was diagnosed by 10-swallow evaluation in 19 (22.1%) with Manoview, and 20 (23.3%) with MMS. On Manoview composite, 17 had DCI <450 mmHg/cm/s, and on MMS composite, 21, (p ≥ 0.85 for each comparison) but these did not impact diagnostic conclusions. Comparison of 10 swallow and composite swallows demonstrate variability in software metrics between manometry systems. Our data support use of manufacturer specific software metrics on 10-swallow sequences. © 2016 John Wiley & Sons Ltd.

  3. Feasibility of and Rationale for the Collection of Orthopaedic Trauma Surgery Quality of Care Metrics.

    PubMed

    Miller, Anna N; Kozar, Rosemary; Wolinsky, Philip

    2017-06-01

    Reproducible metrics are needed to evaluate the delivery of orthopaedic trauma care, national care, norms, and outliers. The American College of Surgeons (ACS) is uniquely positioned to collect and evaluate the data needed to evaluate orthopaedic trauma care via the Committee on Trauma and the Trauma Quality Improvement Project. We evaluated the first quality metrics the ACS has collected for orthopaedic trauma surgery to determine whether these metrics can be appropriately collected with accuracy and completeness. The metrics include the time to administration of the first dose of antibiotics for open fractures, the time to surgical irrigation and débridement of open tibial fractures, and the percentage of patients who undergo stabilization of femoral fractures at trauma centers nationwide. These metrics were analyzed to evaluate for variances in the delivery of orthopaedic care across the country. The data showed wide variances for all metrics, and many centers had incomplete ability to collect the orthopaedic trauma care metrics. There was a large variability in the results of the metrics collected among different trauma center levels, as well as among centers of a particular level. The ACS has successfully begun tracking orthopaedic trauma care performance measures, which will help inform reevaluation of the goals and continued work on data collection and improvement of patient care. Future areas of research may link these performance measures with patient outcomes, such as long-term tracking, to assess nonunion and function. This information can provide insight into center performance and its effect on patient outcomes. The ACS was able to successfully collect and evaluate the data for three metrics used to assess the quality of orthopaedic trauma care. However, additional research is needed to determine whether these metrics are suitable for evaluating orthopaedic trauma care and cutoff values for each metric.

  4. Test Methods for Robot Agility in Manufacturing

    PubMed Central

    Downs, Anthony; Harrison, William; Schlenoff, Craig

    2017-01-01

    Purpose The paper aims to define and describe test methods and metrics to assess industrial robot system agility in both simulation and in reality. Design/methodology/approach The paper describes test methods and associated quantitative and qualitative metrics for assessing robot system efficiency and effectiveness which can then be used for the assessment of system agility. Findings The paper describes how the test methods were implemented in a simulation environment and real world environment. It also shows how the metrics are measured and assessed as they would be in a future competition. Practical Implications The test methods described in this paper will push forward the state of the art in software agility for manufacturing robots, allowing small and medium manufacturers to better utilize robotic systems. Originality / value The paper fulfills the identified need for standard test methods to measure and allow for improvement in software agility for manufacturing robots. PMID:28203034

  5. Usability: Human Research Program - Space Human Factors and Habitability

    NASA Technical Reports Server (NTRS)

    Sandor, Aniko; Holden, Kritina L.

    2009-01-01

    The Usability project addresses the need for research in the area of metrics and methodologies used in hardware and software usability testing in order to define quantifiable and verifiable usability requirements. A usability test is a human-in-the-loop evaluation where a participant works through a realistic set of representative tasks using the hardware/software under investigation. The purpose of this research is to define metrics and methodologies for measuring and verifying usability in the aerospace domain in accordance with FY09 focus on errors, consistency, and mobility/maneuverability. Usability metrics must be predictive of success with the interfaces, must be easy to obtain and/or calculate, and must meet the intent of current Human Systems Integration Requirements (HSIR). Methodologies must work within the constraints of the aerospace domain, be cost and time efficient, and be able to be applied without extensive specialized training.

  6. Memory colours and colour quality evaluation of conventional and solid-state lamps.

    PubMed

    Smet, Kevin A G; Ryckaert, Wouter R; Pointer, Michael R; Deconinck, Geert; Hanselaer, Peter

    2010-12-06

    A colour quality metric based on memory colours is presented. The basic idea is simple. The colour quality of a test source is evaluated as the degree of similarity between the colour appearance of a set of familiar objects and their memory colours. The closer the match, the better the colour quality. This similarity was quantified using a set of similarity distributions obtained by Smet et al. in a previous study. The metric was validated by calculating the Pearson and Spearman correlation coefficients between the metric predictions and the visual appreciation results obtained in a validation experiment conducted by the authors as well those obtained in two independent studies. The metric was found to correlate well with the visual appreciation of the lighting quality of the sources used in the three experiments. Its performance was also compared with that of the CIE colour rendering index and the NIST colour quality scale. For all three experiments, the metric was found to be significantly better at predicting the correct visual rank order of the light sources (p < 0.1).

  7. Driving photomask supplier quality through automation

    NASA Astrophysics Data System (ADS)

    Russell, Drew; Espenscheid, Andrew

    2007-10-01

    In 2005, Freescale Semiconductor's newly centralized mask data prep organization (MSO) initiated a project to develop an automated global quality validation system for photomasks delivered to Freescale Semiconductor fabs. The system handles Certificate of Conformance (CofC) quality metric collection, validation, reporting and an alert system for all photomasks shipped to Freescale fabs from all qualified global suppliers. The completed system automatically collects 30+ quality metrics for each photomask shipped. Other quality metrics are generated from the collected data and quality metric conformance is automatically validated to specifications or control limits with failure alerts emailed to fab photomask and mask data prep engineering. A quality data warehouse stores the data for future analysis, which is performed quarterly. The improved access to data provided by the system has improved Freescale engineers' ability to spot trends and opportunities for improvement with our suppliers' processes. This paper will review each phase of the project, current system capabilities and quality system benefits for both our photomask suppliers and Freescale.

  8. Validation of no-reference image quality index for the assessment of digital mammographic images

    NASA Astrophysics Data System (ADS)

    de Oliveira, Helder C. R.; Barufaldi, Bruno; Borges, Lucas R.; Gabarda, Salvador; Bakic, Predrag R.; Maidment, Andrew D. A.; Schiabel, Homero; Vieira, Marcelo A. C.

    2016-03-01

    To ensure optimal clinical performance of digital mammography, it is necessary to obtain images with high spatial resolution and low noise, keeping radiation exposure as low as possible. These requirements directly affect the interpretation of radiologists. The quality of a digital image should be assessed using objective measurements. In general, these methods measure the similarity between a degraded image and an ideal image without degradation (ground-truth), used as a reference. These methods are called Full-Reference Image Quality Assessment (FR-IQA). However, for digital mammography, an image without degradation is not available in clinical practice; thus, an objective method to assess the quality of mammograms must be performed without reference. The purpose of this study is to present a Normalized Anisotropic Quality Index (NAQI), based on the Rényi entropy in the pseudo-Wigner domain, to assess mammography images in terms of spatial resolution and noise without any reference. The method was validated using synthetic images acquired through an anthropomorphic breast software phantom, and the clinical exposures on anthropomorphic breast physical phantoms and patient's mammograms. The results reported by this noreference index follow the same behavior as other well-established full-reference metrics, e.g., the peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM). Reductions of 50% on the radiation dose in phantom images were translated as a decrease of 4dB on the PSNR, 25% on the SSIM and 33% on the NAQI, evidencing that the proposed metric is sensitive to the noise resulted from dose reduction. The clinical results showed that images reduced to 53% and 30% of the standard radiation dose reported reductions of 15% and 25% on the NAQI, respectively. Thus, this index may be used in clinical practice as an image quality indicator to improve the quality assurance programs in mammography; hence, the proposed method reduces the subjectivity inter-observers in the reporting of image quality assessment.

  9. A Locally Weighted Fixation Density-Based Metric for Assessing the Quality of Visual Saliency Predictions

    NASA Astrophysics Data System (ADS)

    Gide, Milind S.; Karam, Lina J.

    2016-08-01

    With the increased focus on visual attention (VA) in the last decade, a large number of computational visual saliency methods have been developed over the past few years. These models are traditionally evaluated by using performance evaluation metrics that quantify the match between predicted saliency and fixation data obtained from eye-tracking experiments on human observers. Though a considerable number of such metrics have been proposed in the literature, there are notable problems in them. In this work, we discuss shortcomings in existing metrics through illustrative examples and propose a new metric that uses local weights based on fixation density which overcomes these flaws. To compare the performance of our proposed metric at assessing the quality of saliency prediction with other existing metrics, we construct a ground-truth subjective database in which saliency maps obtained from 17 different VA models are evaluated by 16 human observers on a 5-point categorical scale in terms of their visual resemblance with corresponding ground-truth fixation density maps obtained from eye-tracking data. The metrics are evaluated by correlating metric scores with the human subjective ratings. The correlation results show that the proposed evaluation metric outperforms all other popular existing metrics. Additionally, the constructed database and corresponding subjective ratings provide an insight into which of the existing metrics and future metrics are better at estimating the quality of saliency prediction and can be used as a benchmark.

  10. Evaluation techniques and metrics for assessment of pan+MSI fusion (pansharpening)

    NASA Astrophysics Data System (ADS)

    Mercovich, Ryan A.

    2015-05-01

    Fusion of broadband panchromatic data with narrow band multispectral data - pansharpening - is a common and often studied problem in remote sensing. Many methods exist to produce data fusion results with the best possible spatial and spectral characteristics, and a number have been commercially implemented. This study examines the output products of 4 commercial implementations with regard to their relative strengths and weaknesses for a set of defined image characteristics and analyst use-cases. Image characteristics used are spatial detail, spatial quality, spectral integrity, and composite color quality (hue and saturation), and analyst use-cases included a variety of object detection and identification tasks. The imagery comes courtesy of the RIT SHARE 2012 collect. Two approaches are used to evaluate the pansharpening methods, analyst evaluation or qualitative measure and image quality metrics or quantitative measures. Visual analyst evaluation results are compared with metric results to determine which metrics best measure the defined image characteristics and product use-cases and to support future rigorous characterization the metrics' correlation with the analyst results. Because pansharpening represents a trade between adding spatial information from the panchromatic image, and retaining spectral information from the MSI channels, the metrics examined are grouped into spatial improvement metrics and spectral preservation metrics. A single metric to quantify the quality of a pansharpening method would necessarily be a combination of weighted spatial and spectral metrics based on the importance of various spatial and spectral characteristics for the primary task of interest. Appropriate metrics and weights for such a combined metric are proposed here, based on the conducted analyst evaluation. Additionally, during this work, a metric was developed specifically focused on assessment of spatial structure improvement relative to a reference image and independent of scene content. Using analysis of Fourier transform images, a measure of high-frequency content is computed in small sub-segments of the image. The average increase in high-frequency content across the image is used as the metric, where averaging across sub-segments combats the scene dependent nature of typical image sharpness techniques. This metric had an improved range of scores, better representing difference in the test set than other common spatial structure metrics.

  11. Fitting the curve in Excel®: Systematic curve fitting of laboratory and remotely sensed planetary spectra

    NASA Astrophysics Data System (ADS)

    McCraig, Michael A.; Osinski, Gordon R.; Cloutis, Edward A.; Flemming, Roberta L.; Izawa, Matthew R. M.; Reddy, Vishnu; Fieber-Beyer, Sherry K.; Pompilio, Loredana; van der Meer, Freek; Berger, Jeffrey A.; Bramble, Michael S.; Applin, Daniel M.

    2017-03-01

    Spectroscopy in planetary science often provides the only information regarding the compositional and mineralogical make up of planetary surfaces. The methods employed when curve fitting and modelling spectra can be confusing and difficult to visualize and comprehend. Researchers who are new to working with spectra may find inadequate help or documentation in the scientific literature or in the software packages available for curve fitting. This problem also extends to the parameterization of spectra and the dissemination of derived metrics. Often, when derived metrics are reported, such as band centres, the discussion of exactly how the metrics were derived, or if there was any systematic curve fitting performed, is not included. Herein we provide both recommendations and methods for curve fitting and explanations of the terms and methods used. Techniques to curve fit spectral data of various types are demonstrated using simple-to-understand mathematics and equations written to be used in Microsoft Excel® software, free of macros, in a cut-and-paste fashion that allows one to curve fit spectra in a reasonably user-friendly manner. The procedures use empirical curve fitting, include visualizations, and ameliorates many of the unknowns one may encounter when using black-box commercial software. The provided framework is a comprehensive record of the curve fitting parameters used, the derived metrics, and is intended to be an example of a format for dissemination when curve fitting data.

  12. Image quality metrics for volumetric laser displays

    NASA Astrophysics Data System (ADS)

    Williams, Rodney D.; Donohoo, Daniel

    1991-08-01

    This paper addresses the extensions to the image quality metrics and related human factors research that are needed to establish the baseline standards for emerging volume display technologies. The existing and recently developed technologies for multiplanar volume displays are reviewed with an emphasis on basic human visual issues. Human factors image quality metrics and guidelines are needed to firmly establish this technology in the marketplace. The human visual requirements and the display design tradeoffs for these prototype laser-based volume displays are addressed and several critical image quality issues identified for further research. The American National Standard for Human Factors Engineering of Visual Display Terminal Workstations (ANSIHFS-100) and other international standards (ISO, DIN) can serve as a starting point, but this research base must be extended to provide new image quality metrics for this new technology for volume displays.

  13. The SoRReL papers: Recent publications of the Software Reuse Repository Lab

    NASA Technical Reports Server (NTRS)

    Eichmann, David A. (Editor)

    1992-01-01

    The entire publication is presented of some of the papers recently published by the SoRReL. Some typical titles are as follows: Design of a Lattice-Based Faceted Classification System; A Hybrid Approach to Software Reuse Repository Retrieval; Selecting Reusable Components Using Algebraic Specifications; Neural Network-Based Retrieval from Reuse Repositories; and A Neural Net-Based Approach to Software Metrics.

  14. Self-Metric Software. Volume I. Summary of Technical Progress.

    DTIC Science & Technology

    1980-04-01

    Development: A CSDL Project History, RADC-TR-77-213, pp. 33-41. A-42186. [3] Goodenough, J. B. and Zara , R. V., "The Effect of Software Structure on Software...1979. **Visiting assistant professor. 99 MISION Of Rome Air Devlopmnt Centfr RWV pta"aa nd eXgdatAA ’~AW&W4 dwveput, ’t* &a -a # "*ate 4UZtLug ~W~A~n

  15. Software Obfuscation With Symmetric Cryptography

    DTIC Science & Technology

    2008-03-01

    of y = a * b + c Against Random Functions ...............84 Appendix C: Black-box Analysis of Fibonacci Against Random Functions...Metric ................... 67 Figure 19. Standard Deviations of All Fibonacci Output Bits by Metric ........................ 67 Figure 20...caveat to encryption strength is that what may be strong presently may not always be strong; the Data Encryption Standard ( DES ) was once considered

  16. Spatial-temporal distortion metric for in-service quality monitoring of any digital video system

    NASA Astrophysics Data System (ADS)

    Wolf, Stephen; Pinson, Margaret H.

    1999-11-01

    Many organizations have focused on developing digital video quality metrics which produce results that accurately emulate subjective responses. However, to be widely applicable a metric must also work over a wide range of quality, and be useful for in-service quality monitoring. The Institute for Telecommunication Sciences (ITS) has developed spatial-temporal distortion metrics that meet all of these requirements. These objective metrics are described in detail and have a number of interesting properties, including utilization of (1) spatial activity filters which emphasize long edges on the order of 10 arc min while simultaneously performing large amounts of noise suppression, (2) the angular direction of the spatial gradient, (3) spatial-temporal compression factors of at least 384:1 (spatial compression of at least 64:1 and temporal compression of at least 6:1, and 4) simple perceptibility thresholds and spatial-temporal masking functions. Results are presented that compare the objective metric values with mean opinion scores from a wide range of subjective data bases spanning many different scenes, systems, bit-rates, and applications.

  17. Social network of PESCA (Open Source Platform for eHealth).

    PubMed

    Sanchez, Carlos L; Romero-Cuevas, Miguel; Lopez, Diego M; Lorca, Julio; Alcazar, Francisco J; Ruiz, Sergio; Mercado, Carmen; Garcia-Fortea, Pedro

    2008-01-01

    Information and Communication Technologies (ICTs) are revolutionizing how healthcare systems deliver top-quality care to citizens. In this way, Open Source Software (OSS) has demonstrated to be an important strategy to spread ICTs use. Several human and technological barriers in adopting OSS for healthcare have been identified. Human barriers include user acceptance, limited support, technical skillfulness, awareness, resistance to change, etc., while Technological barriers embrace need for open standards, heterogeneous OSS developed without normalization and metrics, lack of initiatives to evaluate existing health OSS and need for quality control and functional validation. The goals of PESCA project are to create a platform of interoperable modules to evaluate, classify and validate good practices in health OSS. Furthermore, a normalization platform will provide interoperable solutions in the fields of healthcare services, health surveillance, health literature, and health education, knowledge and research. Within the platform, the first goal to achieve is the setup of the collaborative work infrastructure. The platform is being organized as a Social Network which works to evaluate five scopes of every existing open source tools for eHealth: Open Source Software, Quality, Pedagogical, Security and privacy and Internationalization/I18N. In the meantime, the knowledge collected from the networking will configure a Good Practice Repository on eHealth promoting the effective use of ICT on behalf of the citizen's health.

  18. Pressure-specific and multiple pressure response of fish assemblages in European running waters☆

    PubMed Central

    Schinegger, Rafaela; Trautwein, Clemens; Schmutz, Stefan

    2013-01-01

    We classified homogenous river types across Europe and searched for fish metrics qualified to show responses to specific pressures (hydromorphological pressures or water quality pressures) vs. multiple pressures in these river types. We analysed fish taxa lists from 3105 sites in 16 ecoregions and 14 countries. Sites were pre-classified for 15 selected pressures to separate unimpacted from impacted sites. Hierarchical cluster analysis was used to split unimpacted sites into four homogenous river types based on species composition and geographical location. Classification trees were employed to predict associated river types for impacted sites with four environmental variables. We defined a set of 129 candidate fish metrics to select the best reacting metrics for each river type. The candidate metrics represented tolerances/intolerances of species associated with six metric types: habitat, migration, water quality sensitivity, reproduction, trophic level and biodiversity. The results showed that 17 uncorrelated metrics reacted to pressures in the four river types. Metrics responded specifically to water quality pressures and hydromorphological pressures in three river types and to multiple pressures in all river types. Four metrics associated with water quality sensitivity showed a significant reaction in up to three river types, whereas 13 metrics were specific to individual river types. Our results contribute to the better understanding of fish assemblage response to human pressures at a pan-European scale. The results are especially important for European river management and restoration, as it is necessary to uncover underlying processes and effects of human pressures on aquatic communities. PMID:24003262

  19. QUAST: quality assessment tool for genome assemblies.

    PubMed

    Gurevich, Alexey; Saveliev, Vladislav; Vyahhi, Nikolay; Tesler, Glenn

    2013-04-15

    Limitations of genome sequencing techniques have led to dozens of assembly algorithms, none of which is perfect. A number of methods for comparing assemblers have been developed, but none is yet a recognized benchmark. Further, most existing methods for comparing assemblies are only applicable to new assemblies of finished genomes; the problem of evaluating assemblies of previously unsequenced species has not been adequately considered. Here, we present QUAST-a quality assessment tool for evaluating and comparing genome assemblies. This tool improves on leading assembly comparison software with new ideas and quality metrics. QUAST can evaluate assemblies both with a reference genome, as well as without a reference. QUAST produces many reports, summary tables and plots to help scientists in their research and in their publications. In this study, we used QUAST to compare several genome assemblers on three datasets. QUAST tables and plots for all of them are available in the Supplementary Material, and interactive versions of these reports are on the QUAST website. http://bioinf.spbau.ru/quast . Supplementary data are available at Bioinformatics online.

  20. Performance evaluation of no-reference image quality metrics for face biometric images

    NASA Astrophysics Data System (ADS)

    Liu, Xinwei; Pedersen, Marius; Charrier, Christophe; Bours, Patrick

    2018-03-01

    The accuracy of face recognition systems is significantly affected by the quality of face sample images. The recent established standardization proposed several important aspects for the assessment of face sample quality. There are many existing no-reference image quality metrics (IQMs) that are able to assess natural image quality by taking into account similar image-based quality attributes as introduced in the standardization. However, whether such metrics can assess face sample quality is rarely considered. We evaluate the performance of 13 selected no-reference IQMs on face biometrics. The experimental results show that several of them can assess face sample quality according to the system performance. We also analyze the strengths and weaknesses of different IQMs as well as why some of them failed to assess face sample quality. Retraining an original IQM by using face database can improve the performance of such a metric. In addition, the contribution of this paper can be used for the evaluation of IQMs on other biometric modalities; furthermore, it can be used for the development of multimodality biometric IQMs.

  1. Software errors and complexity: An empirical investigation

    NASA Technical Reports Server (NTRS)

    Basili, Victor R.; Perricone, Berry T.

    1983-01-01

    The distributions and relationships derived from the change data collected during the development of a medium scale satellite software project show that meaningful results can be obtained which allow an insight into software traits and the environment in which it is developed. Modified and new modules were shown to behave similarly. An abstract classification scheme for errors which allows a better understanding of the overall traits of a software project is also shown. Finally, various size and complexity metrics are examined with respect to errors detected within the software yielding some interesting results.

  2. Software errors and complexity: An empirical investigation

    NASA Technical Reports Server (NTRS)

    Basili, V. R.; Perricone, B. T.

    1982-01-01

    The distributions and relationships derived from the change data collected during the development of a medium scale satellite software project show that meaningful results can be obtained which allow an insight into software traits and the environment in which it is developed. Modified and new modules were shown to behave similarly. An abstract classification scheme for errors which allows a better understanding of the overall traits of a software project is also shown. Finally, various size and complexity metrics are examined with respect to errors detected within the software yielding some interesting results.

  3. Quality of service routing in the differentiated services framework

    NASA Astrophysics Data System (ADS)

    Oliveira, Marilia C.; Melo, Bruno; Quadros, Goncalo; Monteiro, Edmundo

    2001-02-01

    In this paper we present a quality of service routing strategy for network where traffic differentiation follows the class-based paradigm, as in the Differentiated Services framework. This routing strategy is based on a metric of quality of service. This metric represents the impact that delay and losses verified at each router in the network have in application performance. Based on this metric, it is selected a path for each class according to the class sensitivity to delay and losses. The distribution of the metric is triggered by a relative criterion with two thresholds, and the values advertised are the moving average of the last values measured.

  4. The Software Maturity Matrix: A Software Performance Metric

    DTIC Science & Technology

    2003-01-28

    are for Managing n Use Them! n Unused measurements have the same value as last night’s unused hotel room or an empty airline seat. n Be Prepared to...standard measurements are implicit n Organization standard verification is implicit n Organization standard SMM training can be the basis of an

  5. Investigation of Presage 3D Dosimetry as a Method of Clinically Intuitive Quality Assurance and Comparison to a Semi-3D Delta4 System

    NASA Astrophysics Data System (ADS)

    Crockett, Ethan Van

    The need for clinically intuitive metrics for patient-specific quality assurance in radiation therapy has been well-documented (Zhen, Nelms et al. 2011). A novel transform method has shown to be effective at converting full-density 3D dose measurements made in a phantom to dose values in the patient geometry, enabling comparisons using clinically intuitive metrics such as dose-volume histograms (Oldham et al. 2011). This work investigates the transform method and compares its calculated dose-volume histograms (DVHs) to DVH values calculated by a Delta4 QA device (Scandidos), marking the first comparison of a true 3D system to a semi-3D device using clinical metrics. Measurements were made using Presage 3D dosimeters, which were readout by an in-house optical-CT scanner. Three patient cases were chosen for the study: one head-and-neck VMAT treatment and two spine IMRT treatments. The transform method showed good agreement with the planned dose values for all three cases. Furthermore, the transformed DVHs adhered to the planned dose with more accuracy than the Delta4 DVHs. The similarity between the Delta4 DVHs and the transformed DVHs, however, was greater for one of the spine cases than it was for the head-and-neck case, implying that the accuracy of the Delta4 Anatomy software may vary from one treatment site to another. Overall, the transform method, which incorporates data from full-density 3D dose measurements, provides clinically intuitive results that are more accurate and consistent than the corresponding results from a semi-3D Delta 4 system.

  6. Comparative performance evaluation of a new a-Si EPID that exceeds quad high-definition resolution.

    PubMed

    McConnell, Kristen A; Alexandrian, Ara; Papanikolaou, Niko; Stathakis, Sotiri

    2018-01-01

    Electronic portal imaging devices (EPIDs) are an integral part of the radiation oncology workflow for treatment setup verification. Several commercial EPID implementations are currently available, each with varying capabilities. To standardize performance evaluation, Task Group Report 58 (TG-58) and TG-142 outline specific image quality metrics to be measured. A LinaTech Image Viewing System (IVS), with the highest commercially available pixel matrix (2688x2688 pixels), was independently evaluated and compared to an Elekta iViewGT (1024x1024 pixels) and a Varian aSi-1000 (1024x768 pixels) using a PTW EPID QC Phantom. The IVS, iViewGT, and aSi-1000 were each used to acquire 20 images of the PTW QC Phantom. The QC phantom was placed on the couch and aligned at isocenter. The images were exported and analyzed using the epidSoft image quality assurance (QA) software. The reported metrics were signal linearity, isotropy of signal linearity, signal-tonoise ratio (SNR), low contrast resolution, and high-contrast resolution. These values were compared between the three EPID solutions. Computed metrics demonstrated comparable results between the EPID solutions with the IVS outperforming the aSi-1000 and iViewGT in the low and high-contrast resolution analysis. The performance of three commercial EPID solutions have been quantified, evaluated, and compared using results from the PTW QC Phantom. The IVS outperformed the other panels in low and high-contrast resolution, but to fully realize the benefits of the IVS, the selection of the monitor on which to view the high-resolution images is important to prevent down sampling and visual of resolution.

  7. Quality assessment of color images based on the measure of just noticeable color difference

    NASA Astrophysics Data System (ADS)

    Chou, Chun-Hsien; Hsu, Yun-Hsiang

    2014-01-01

    Accurate assessment on the quality of color images is an important step to many image processing systems that convey visual information of the reproduced images. An accurate objective image quality assessment (IQA) method is expected to give the assessment result highly agreeing with the subjective assessment. To assess the quality of color images, many approaches simply apply the metric for assessing the quality of gray scale images to each of three color channels of the color image, neglecting the correlation among three color channels. In this paper, a metric for assessing color images' quality is proposed, in which the model of variable just-noticeable color difference (VJNCD) is employed to estimate the visibility thresholds of distortion inherent in each color pixel. With the estimated visibility thresholds of distortion, the proposed metric measures the average perceptible distortion in terms of the quantized distortion according to the perceptual error map similar to that defined by National Bureau of Standards (NBS) for converting the color difference enumerated by CIEDE2000 to the objective score of perceptual quality assessment. The perceptual error map in this case is designed for each pixel according to the visibility threshold estimated by the VJNCD model. The performance of the proposed metric is verified by assessing the test images in the LIVE database, and is compared with those of many well-know IQA metrics. Experimental results indicate that the proposed metric is an effective IQA method that can accurately predict the image quality of color images in terms of the correlation between objective scores and subjective evaluation.

  8. Measures and metrics for software development

    NASA Technical Reports Server (NTRS)

    1984-01-01

    The evaluations of and recommendations for the use of software development measures based on the practical and analytical experience of the Software Engineering Laboratory are discussed. The basic concepts of measurement and system of classification for measures are described. The principal classes of measures defined are explicit, analytic, and subjective. Some of the major software measurement schemes appearing in the literature are derived. The applications of specific measures in a production environment are explained. These applications include prediction and planning, review and assessment, and evaluation and selection.

  9. San Antonio I Software Workshop Proceedings. DoD Software for the 1990s, Held in San Antonio, Texas on 28 January - 1 February 1991

    DTIC Science & Technology

    1991-12-01

    management and engineering issues common to the military-industrial complex, - to learn from past experience, - to understand future software...prospective policy documents. - :Prepare a draft issue paper and presentation for the DAE. These items should address the key implementation issues with...respect to MCCR software metrics and establish a clear need for DAE support. Long Term Actions ( past 12-18 mcnths) ... Draft final implementation

  10. Evaluations of UltraiQ software for objective ultrasound image quality assessment using images from a commercial scanner.

    PubMed

    Long, Zaiyang; Tradup, Donald J; Stekel, Scott F; Gorny, Krzysztof R; Hangiandreou, Nicholas J

    2018-03-01

    We evaluated a commercially available software package that uses B-mode images to semi-automatically measure quantitative metrics of ultrasound image quality, such as contrast response, depth of penetration (DOP), and spatial resolution (lateral, axial, and elevational). Since measurement of elevational resolution is not a part of the software package, we achieved it by acquiring phantom images with transducers tilted at 45 degrees relative to the phantom. Each measurement was assessed in terms of measurement stability, sensitivity, repeatability, and semi-automated measurement success rate. All assessments were performed on a GE Logiq E9 ultrasound system with linear (9L or 11L), curved (C1-5), and sector (S1-5) transducers, using a CIRS model 040GSE phantom. In stability tests, the measurements of contrast, DOP, and spatial resolution remained within a ±10% variation threshold in 90%, 100%, and 69% of cases, respectively. In sensitivity tests, contrast, DOP, and spatial resolution measurements followed the expected behavior in 100%, 100%, and 72% of cases, respectively. In repeatability testing, intra- and inter-individual coefficients of variations were equal to or less than 3.2%, 1.3%, and 4.4% for contrast, DOP, and spatial resolution (lateral and axial), respectively. The coefficients of variation corresponding to the elevational resolution test were all within 9.5%. Overall, in our assessment, the evaluated package performed well for objective and quantitative assessment of the above-mentioned image qualities under well-controlled acquisition conditions. We are finding it to be useful for various clinical ultrasound applications including performance comparison between scanners from different vendors. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  11. The compressed average image intensity metric for stereoscopic video quality assessment

    NASA Astrophysics Data System (ADS)

    Wilczewski, Grzegorz

    2016-09-01

    The following article depicts insights towards design, creation and testing of a genuine metric designed for a 3DTV video quality evaluation. The Compressed Average Image Intensity (CAII) mechanism is based upon stereoscopic video content analysis, setting its core feature and functionality to serve as a versatile tool for an effective 3DTV service quality assessment. Being an objective type of quality metric it may be utilized as a reliable source of information about the actual performance of a given 3DTV system, under strict providers evaluation. Concerning testing and the overall performance analysis of the CAII metric, the following paper presents comprehensive study of results gathered across several testing routines among selected set of samples of stereoscopic video content. As a result, the designed method for stereoscopic video quality evaluation is investigated across the range of synthetic visual impairments injected into the original video stream.

  12. JPEG2000 still image coding quality.

    PubMed

    Chen, Tzong-Jer; Lin, Sheng-Chieh; Lin, You-Chen; Cheng, Ren-Gui; Lin, Li-Hui; Wu, Wei

    2013-10-01

    This work demonstrates the image qualities between two popular JPEG2000 programs. Two medical image compression algorithms are both coded using JPEG2000, but they are different regarding the interface, convenience, speed of computation, and their characteristic options influenced by the encoder, quantization, tiling, etc. The differences in image quality and compression ratio are also affected by the modality and compression algorithm implementation. Do they provide the same quality? The qualities of compressed medical images from two image compression programs named Apollo and JJ2000 were evaluated extensively using objective metrics. These algorithms were applied to three medical image modalities at various compression ratios ranging from 10:1 to 100:1. Following that, the quality of the reconstructed images was evaluated using five objective metrics. The Spearman rank correlation coefficients were measured under every metric in the two programs. We found that JJ2000 and Apollo exhibited indistinguishable image quality for all images evaluated using the above five metrics (r > 0.98, p < 0.001). It can be concluded that the image quality of the JJ2000 and Apollo algorithms is statistically equivalent for medical image compression.

  13. A management-oriented framework for selecting metrics used to assess habitat- and path-specific quality in spatially structured populations

    USGS Publications Warehouse

    Nicol, Sam; Wiederholt, Ruscena; Diffendorfer, James E.; Mattsson, Brady; Thogmartin, Wayne E.; Semmens, Darius J.; Laura Lopez-Hoffman,; Norris, Ryan

    2016-01-01

    Mobile species with complex spatial dynamics can be difficult to manage because their population distributions vary across space and time, and because the consequences of managing particular habitats are uncertain when evaluated at the level of the entire population. Metrics to assess the importance of habitats and pathways connecting habitats in a network are necessary to guide a variety of management decisions. Given the many metrics developed for spatially structured models, it can be challenging to select the most appropriate one for a particular decision. To guide the management of spatially structured populations, we define three classes of metrics describing habitat and pathway quality based on their data requirements (graph-based, occupancy-based, and demographic-based metrics) and synopsize the ecological literature relating to these classes. Applying the first steps of a formal decision-making approach (problem framing, objectives, and management actions), we assess the utility of metrics for particular types of management decisions. Our framework can help managers with problem framing, choosing metrics of habitat and pathway quality, and to elucidate the data needs for a particular metric. Our goal is to help managers to narrow the range of suitable metrics for a management project, and aid in decision-making to make the best use of limited resources.

  14. Evaluation of 3D Gamma index calculation implemented in two commercial dosimetry systems

    NASA Astrophysics Data System (ADS)

    Xing, Aitang; Arumugam, Sankar; Deshpande, Shrikant; George, Armia; Vial, Philip; Holloway, Lois; Goozee, Gary

    2015-01-01

    3D Gamma index is one of the metrics which have been widely used for clinical routine patient specific quality assurance for IMRT, Tomotherapy and VMAT. The algorithms for calculating the 3D Gamma index using global and local methods implemented in two software tools: PTW- VeriSoft® as a part of OCTIVIUS 4D dosimeter systems and 3DVHTM from Sun Nuclear were assessed. The Gamma index calculated by the two systems was compared with manual calculated for one data set. The Gamma pass rate calculated by the two systems was compared using 3%/3mm, 2%/2mm, 3%/2mm and 2%/3mm for two additional data sets. The Gamma indexes calculated by the two systems were accurate, but Gamma pass rates calculated by the two software tools for same data set with the same dose threshold were different due to the different interpolation of raw dose data by the two systems and different implementation of Gamma index calculation and other modules in the two software tools. The mean difference was -1.3%±3.38 (1SD) with a maximum difference of 11.7%.

  15. Safety considerations in providing allergen immunotherapy in the office.

    PubMed

    Mattos, Jose L; Lee, Stella

    2016-06-01

    This review highlights the risks of allergy immunotherapy, methods to improve the quality and safety of allergy treatment, the current status of allergy quality metrics, and the future of quality measurement. In the current healthcare environment, the emphasis on outcomes measurement is increasing, and providers must be better equipped in the development, measurement, and reporting of safety and quality measures. Immunotherapy offers the only potential cure for allergic disease and asthma. Although well tolerated and effective, immunotherapy can be associated with serious consequence, including anaphylaxis and death. Many predisposing factors and errors that lead to serious systemic reactions are preventable, and the evaluation and implementation of quality measures are crucial to developing a safe immunotherapy practice. Although quality metrics for immunotherapy are in their infancy, they will become increasingly sophisticated, and providers will face increased pressure to deliver safe, high-quality, patient-centered, evidence-based, and efficient allergy care. The establishment of safety in the allergy office involves recognition of potential risk factors for anaphylaxis, the development and measurement of quality metrics, and changing systems-wide practices if needed. Quality improvement is a continuous process, and although national allergy-specific quality metrics do not yet exist, they are in development.

  16. Quantifying forest fragmentation using Geographic Information Systems and Forest Inventory and Analysis plot data

    Treesearch

    Dacia M. Meneguzzo; Mark H. Hansen

    2009-01-01

    Fragmentation metrics provide a means of quantifying and describing forest fragmentation. The most common method of calculating these metrics is through the use of Geographic Information System software to analyze raster data, such as a satellite or aerial image of the study area; however, the spatial resolution of the imagery has a significant impact on the results....

  17. Creating an automated tool for measuring software cohesion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tutton, J.M.; Zucconi, L.

    1994-05-06

    Program modules with high complexity tend to be more error prone and more difficult to understand. These factors increase maintenance and enhancement costs. Hence, a tool that can help programmers determine a key factor in module complexity should be very useful. Our goal is to create a software tool that will automatically give a quantitative measure of the cohesiveness of a given module, and hence give us an estimate of the {open_quotes}maintainability{close_quotes} of that module. The Tool will use a metric developed by Professors Linda M. Ott and James M. Bieman. The Ott/Bieman metric gives quantitative measures that indicate themore » degree of functional cohesion using abstract data slices.« less

  18. Compression performance comparison in low delay real-time video for mobile applications

    NASA Astrophysics Data System (ADS)

    Bivolarski, Lazar

    2012-10-01

    This article compares the performance of several current video coding standards in the conditions of low-delay real-time in a resource constrained environment. The comparison is performed using the same content and the metrics and mix of objective and perceptual quality metrics. The metrics results in different coding schemes are analyzed from a point of view of user perception and quality of service. Multiple standards are compared MPEG-2, MPEG4 and MPEG-AVC and well and H.263. The metrics used in the comparison include SSIM, VQM and DVQ. Subjective evaluation and quality of service are discussed from a point of view of perceptual metrics and their incorporation in the coding scheme development process. The performance and the correlation of results are presented as a predictor of the performance of video compression schemes.

  19. No-reference image quality assessment for horizontal-path imaging scenarios

    NASA Astrophysics Data System (ADS)

    Rios, Carlos; Gladysz, Szymon

    2013-05-01

    There exist several image-enhancement algorithms and tasks associated with imaging through turbulence that depend on defining the quality of an image. Examples include: "lucky imaging", choosing the width of the inverse filter for image reconstruction, or stopping iterative deconvolution. We collected a number of image quality metrics found in the literature. Particularly interesting are the blind, "no-reference" metrics. We discuss ways of evaluating the usefulness of these metrics, even when a fully objective comparison is impossible because of the lack of a reference image. Metrics are tested on simulated and real data. Field data comes from experiments performed by the NATO SET 165 research group over a 7 km distance in Dayton, Ohio.

  20. Toward objective image quality metrics: the AIC Eval Program of the JPEG

    NASA Astrophysics Data System (ADS)

    Richter, Thomas; Larabi, Chaker

    2008-08-01

    Objective quality assessment of lossy image compression codecs is an important part of the recent call of the JPEG for Advanced Image Coding. The target of the AIC ad-hoc group is twofold: First, to receive state-of-the-art still image codecs and to propose suitable technology for standardization; and second, to study objective image quality metrics to evaluate the performance of such codes. Even tthough the performance of an objective metric is defined by how well it predicts the outcome of a subjective assessment, one can also study the usefulness of a metric in a non-traditional way indirectly, namely by measuring the subjective quality improvement of a codec that has been optimized for a specific objective metric. This approach shall be demonstrated here on the recently proposed HDPhoto format14 introduced by Microsoft and a SSIM-tuned17 version of it by one of the authors. We compare these two implementations with JPEG1 in two variations and a visual and PSNR optimal JPEG200013 implementation. To this end, we use subjective and objective tests based on the multiscale SSIM and a new DCT based metric.

  1. Model and Interoperability using Meta Data Annotations

    NASA Astrophysics Data System (ADS)

    David, O.

    2011-12-01

    Software frameworks and architectures are in need for meta data to efficiently support model integration. Modelers have to know the context of a model, often stepping into modeling semantics and auxiliary information usually not provided in a concise structure and universal format, consumable by a range of (modeling) tools. XML often seems the obvious solution for capturing meta data, but its wide adoption to facilitate model interoperability is limited by XML schema fragmentation, complexity, and verbosity outside of a data-automation process. Ontologies seem to overcome those shortcomings, however the practical significance of their use remains to be demonstrated. OMS version 3 took a different approach for meta data representation. The fundamental building block of a modular model in OMS is a software component representing a single physical process, calibration method, or data access approach. Here, programing language features known as Annotations or Attributes were adopted. Within other (non-modeling) frameworks it has been observed that annotations lead to cleaner and leaner application code. Framework-supported model integration, traditionally accomplished using Application Programming Interfaces (API) calls is now achieved using descriptive code annotations. Fully annotated components for various hydrological and Ag-system models now provide information directly for (i) model assembly and building, (ii) data flow analysis for implicit multi-threading or visualization, (iii) automated and comprehensive model documentation of component dependencies, physical data properties, (iv) automated model and component testing, calibration, and optimization, and (v) automated audit-traceability to account for all model resources leading to a particular simulation result. Such a non-invasive methodology leads to models and modeling components with only minimal dependencies on the modeling framework but a strong reference to its originating code. Since models and modeling components are not directly bound to framework by the use of specific APIs and/or data types they can more easily be reused both within the framework as well as outside. While providing all those capabilities, a significant reduction in the size of the model source code was achieved. To support the benefit of annotations for a modeler, studies were conducted to evaluate the effectiveness of an annotation based framework approach with other modeling frameworks and libraries, a framework-invasiveness study was conducted to evaluate the effects of framework design on model code quality. A typical hydrological model was implemented across several modeling frameworks and several software metrics were collected. The metrics selected were measures of non-invasive design methods for modeling frameworks from a software engineering perspective. It appears that the use of annotations positively impacts several software quality measures. Experience to date has demonstrated the multi-purpose value of using annotations. Annotations are also a feasible and practical method to enable interoperability among models and modeling frameworks.

  2. Advanced Life Support Research and Technology Development Metric

    NASA Technical Reports Server (NTRS)

    Hanford, A. J.

    2004-01-01

    The Metric is one of several measures employed by the NASA to assess the Agency s progress as mandated by the United States Congress and the Office of Management and Budget. Because any measure must have a reference point, whether explicitly defined or implied, the Metric is a comparison between a selected ALS Project life support system and an equivalently detailed life support system using technology from the Environmental Control and Life Support System (ECLSS) for the International Space Station (ISS). This document provides the official calculation of the Advanced Life Support (ALS) Research and Technology Development Metric (the Metric) for Fiscal Year 2004. The values are primarily based on Systems Integration, Modeling, and Analysis (SIMA) Element approved software tools or reviewed and approved reference documents. For Fiscal Year 2004, the Advanced Life Support Research and Technology Development Metric value is 2.03 for an Orbiting Research Facility and 1.62 for an Independent Exploration Mission.

  3. MFV-class: a multi-faceted visualization tool of object classes.

    PubMed

    Zhang, Zhi-meng; Pan, Yun-he; Zhuang, Yue-ting

    2004-11-01

    Classes are key software components in an object-oriented software system. In many industrial OO software systems, there are some classes that have complicated structure and relationships. So in the processes of software maintenance, testing, software reengineering, software reuse and software restructure, it is a challenge for software engineers to understand these classes thoroughly. This paper proposes a class comprehension model based on constructivist learning theory, and implements a software visualization tool (MFV-Class) to help in the comprehension of a class. The tool provides multiple views of class to uncover manifold facets of class contents. It enables visualizing three object-oriented metrics of classes to help users focus on the understanding process. A case study was conducted to evaluate our approach and the toolkit.

  4. A Flexible and Non-instrusive Approach for Computing Complex Structural Coverage Metrics

    NASA Technical Reports Server (NTRS)

    Whalen, Michael W.; Person, Suzette J.; Rungta, Neha; Staats, Matt; Grijincu, Daniela

    2015-01-01

    Software analysis tools and techniques often leverage structural code coverage information to reason about the dynamic behavior of software. Existing techniques instrument the code with the required structural obligations and then monitor the execution of the compiled code to report coverage. Instrumentation based approaches often incur considerable runtime overhead for complex structural coverage metrics such as Modified Condition/Decision (MC/DC). Code instrumentation, in general, has to be approached with great care to ensure it does not modify the behavior of the original code. Furthermore, instrumented code cannot be used in conjunction with other analyses that reason about the structure and semantics of the code under test. In this work, we introduce a non-intrusive preprocessing approach for computing structural coverage information. It uses a static partial evaluation of the decisions in the source code and a source-to-bytecode mapping to generate the information necessary to efficiently track structural coverage metrics during execution. Our technique is flexible; the results of the preprocessing can be used by a variety of coverage-driven software analysis tasks, including automated analyses that are not possible for instrumented code. Experimental results in the context of symbolic execution show the efficiency and flexibility of our nonintrusive approach for computing code coverage information

  5. Using Web Metric Software to Drive: Mobile Website Development

    ERIC Educational Resources Information Center

    Tidal, Junior

    2011-01-01

    Many libraries have developed mobile versions of their websites. In order to understand their users, web developers have conducted both usability tests and focus groups, yet analytical software and web server logs can also be used to better understand users. Using data collected from these tools, the Ursula C. Schwerin Library has made informed…

  6. CrossTalk: The Journal of Defense Software Engineering. Volume 18, Number 4

    DTIC Science & Technology

    2005-04-01

    older automated cost- estimating tools are no longer being actively marketed but are still in use such as CheckPoint, COCOMO, ESTIMACS, REVIC, and SPQR ...estimation tools: SPQR /20, Checkpoint, and Knowl- edgePlan. These software estimation tools pioneered the use of function point metrics for sizing and

  7. Assessment of the effects of nickel on benthic macroinvertebrates in the field.

    PubMed

    Peters, Adam; Simpson, Peter; Merrington, Graham; Schlekat, Chris; Rogevich-Garman, Emily

    2014-01-01

    A field-based evaluation of the biological effects of potential nickel (Ni) exposures was conducted using monitoring data for benthic macroinvertebrates and water chemistry parameters for streams in England and Wales. Observed benthic community metrics were compared to expected community metrics under reference conditions using RIVPACS III+ software. In order to evaluate relationships between Ni concentrations and benthic community metrics, bioavailable Ni concentrations were also calculated for each site. A limiting effect from Ni on the 90th percentile of the maximum achievable ecological quality was derived at "bioavailable Ni" exposures of 10.3 μg l(-1). As snails have been identified as particularly sensitive to nickel exposure, snail abundance in the field in response to nickel exposure, relative to reference conditions, was also analysed. A "low effects" threshold for snail abundance based on an average of spring and autumn data was derived as 3.9 μg l(-1) bioavailable Ni. There was no apparent effect of Ni exposure on the abundance of Ephemeroptera (mayflies), Plecoptera (stoneflies) or Tricoptera (caddisflies) when expressed relative to a reference condition within the range of "bioavailable Ni" exposures observed within the dataset. Nickel exposure concentrations co-vary with the concentrations of other stressors in the dataset, and high concentrations of Ni are also associated with elevated concentrations of other contaminants.

  8. Maintenance Metrics for Jovial (J73) Software

    DTIC Science & Technology

    1988-12-01

    pacing technology in advanced fighters, just as it has in most other weapon systems and information systems" ( Canan , 1986:49). Another reason for...the magnitude of the software inside an aircraft may represent only a fraction of that aircraft’s total software requirement." ( Canan , 1986:49) One more...art than a science" marks program development as a largely labor-intensive, human endeavor ( Canan , 1986:50). Individual effort and creativity therefore

  9. Investigation into Text Classification With Kernel Based Schemes

    DTIC Science & Technology

    2010-03-01

    Document Matrix TDMs Term-Document Matrices TMG Text to Matrix Generator TN True Negative TP True Positive VSM Vector Space Model xxii THIS PAGE...are represented as a term-document matrix, common evaluation metrics, and the software package Text to Matrix Generator ( TMG ). The classifier...AND METRICS This chapter introduces the indexing capabilities of the Text to Matrix Generator ( TMG ) Toolbox. Specific attention is placed on the

  10. Productivity in Pediatric Palliative Care: Measuring and Monitoring an Elusive Metric.

    PubMed

    Kaye, Erica C; Abramson, Zachary R; Snaman, Jennifer M; Friebert, Sarah E; Baker, Justin N

    2017-05-01

    Workforce productivity is poorly defined in health care. Particularly in the field of pediatric palliative care (PPC), the absence of consensus metrics impedes aggregation and analysis of data to track workforce efficiency and effectiveness. Lack of uniformly measured data also compromises the development of innovative strategies to improve productivity and hinders investigation of the link between productivity and quality of care, which are interrelated but not interchangeable. To review the literature regarding the definition and measurement of productivity in PPC; to identify barriers to productivity within traditional PPC models; and to recommend novel metrics to study productivity as a component of quality care in PPC. PubMed ® and Cochrane Database of Systematic Reviews searches for scholarly literature were performed using key words (pediatric palliative care, palliative care, team, workforce, workflow, productivity, algorithm, quality care, quality improvement, quality metric, inpatient, hospital, consultation, model) for articles published between 2000 and 2016. Organizational searches of Center to Advance Palliative Care, National Hospice and Palliative Care Organization, National Association for Home Care & Hospice, American Academy of Hospice and Palliative Medicine, Hospice and Palliative Nurses Association, National Quality Forum, and National Consensus Project for Quality Palliative Care were also performed. Additional semistructured interviews were conducted with directors from seven prominent PPC programs across the U.S. to review standard operating procedures for PPC team workflow and productivity. Little consensus exists in the PPC field regarding optimal ways to define, measure, and analyze provider and program productivity. Barriers to accurate monitoring of productivity include difficulties with identification, measurement, and interpretation of metrics applicable to an interdisciplinary care paradigm. In the context of inefficiencies inherent to traditional consultation models, novel productivity metrics are proposed. Further research is needed to determine optimal metrics for monitoring productivity within PPC teams. Innovative approaches should be studied with the goal of improving efficiency of care without compromising value. Copyright © 2016 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.

  11. Image quality assessment metric for frame accumulated image

    NASA Astrophysics Data System (ADS)

    Yu, Jianping; Li, Gang; Wang, Shaohui; Lin, Ling

    2018-01-01

    The medical image quality determines the accuracy of diagnosis, and the gray-scale resolution is an important parameter to measure image quality. But current objective metrics are not very suitable for assessing medical images obtained by frame accumulation technology. Little attention was paid to the gray-scale resolution, basically based on spatial resolution and limited to the 256 level gray scale of the existing display device. Thus, this paper proposes a metric, "mean signal-to-noise ratio" (MSNR) based on signal-to-noise in order to be more reasonable to evaluate frame accumulated medical image quality. We demonstrate its potential application through a series of images under a constant illumination signal. Here, the mean image of enough images was regarded as the reference image. Several groups of images by different frame accumulation and their MSNR were calculated. The results of the experiment show that, compared with other quality assessment methods, the metric is simpler, more effective, and more suitable for assessing frame accumulated images that surpass the gray scale and precision of the original image.

  12. Quality Markers in Cardiology. Main Markers to Measure Quality of Results (Outcomes) and Quality Measures Related to Better Results in Clinical Practice (Performance Metrics). INCARDIO (Indicadores de Calidad en Unidades Asistenciales del Área del Corazón): A SEC/SECTCV Consensus Position Paper.

    PubMed

    López-Sendón, José; González-Juanatey, José Ramón; Pinto, Fausto; Cuenca Castillo, José; Badimón, Lina; Dalmau, Regina; González Torrecilla, Esteban; López-Mínguez, José Ramón; Maceira, Alicia M; Pascual-Figal, Domingo; Pomar Moya-Prats, José Luis; Sionis, Alessandro; Zamorano, José Luis

    2015-11-01

    Cardiology practice requires complex organization that impacts overall outcomes and may differ substantially among hospitals and communities. The aim of this consensus document is to define quality markers in cardiology, including markers to measure the quality of results (outcomes metrics) and quality measures related to better results in clinical practice (performance metrics). The document is mainly intended for the Spanish health care system and may serve as a basis for similar documents in other countries. Copyright © 2015 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  13. Visual quality analysis for images degraded by different types of noise

    NASA Astrophysics Data System (ADS)

    Ponomarenko, Nikolay N.; Lukin, Vladimir V.; Ieremeyev, Oleg I.; Egiazarian, Karen O.; Astola, Jaakko T.

    2013-02-01

    Modern visual quality metrics take into account different peculiarities of the Human Visual System (HVS). One of them is described by the Weber-Fechner law and deals with the different sensitivity to distortions in image fragments with different local mean values (intensity, brightness). We analyze how this property can be incorporated into a metric PSNRHVS- M. It is shown that some improvement of its performance can be provided. Then, visual quality of color images corrupted by three types of i.i.d. noise (pure additive, pure multiplicative, and signal dependent, Poisson) is analyzed. Experiments with a group of observers are carried out for distorted color images created on the basis of TID2008 database. Several modern HVS-metrics are considered. It is shown that even the best metrics are unable to assess visual quality of distorted images adequately enough. The reasons for this deal with the observer's attention to certain objects in the test images, i.e., with semantic aspects of vision, which are worth taking into account in design of HVS-metrics.

  14. Impact of artifact removal on ChIP quality metrics in ChIP-seq and ChIP-exo data

    PubMed Central

    Carroll, Thomas S.; Liang, Ziwei; Salama, Rafik; Stark, Rory; de Santiago, Ines

    2014-01-01

    With the advent of ChIP-seq multiplexing technologies and the subsequent increase in ChIP-seq throughput, the development of working standards for the quality assessment of ChIP-seq studies has received significant attention. The ENCODE consortium's large scale analysis of transcription factor binding and epigenetic marks as well as concordant work on ChIP-seq by other laboratories has established a new generation of ChIP-seq quality control measures. The use of these metrics alongside common processing steps has however not been evaluated. In this study, we investigate the effects of blacklisting and removal of duplicated reads on established metrics of ChIP-seq quality and show that the interpretation of these metrics is highly dependent on the ChIP-seq preprocessing steps applied. Further to this we perform the first investigation of the use of these metrics for ChIP-exo data and make recommendations for the adaptation of the NSC statistic to allow for the assessment of ChIP-exo efficiency. PMID:24782889

  15. Assessing Requirements Quality through Requirements Coverage

    NASA Technical Reports Server (NTRS)

    Rajan, Ajitha; Heimdahl, Mats; Woodham, Kurt

    2008-01-01

    In model-based development, the development effort is centered around a formal description of the proposed software system the model. This model is derived from some high-level requirements describing the expected behavior of the software. For validation and verification purposes, this model can then be subjected to various types of analysis, for example, completeness and consistency analysis [6], model checking [3], theorem proving [1], and test-case generation [4, 7]. This development paradigm is making rapid inroads in certain industries, e.g., automotive, avionics, space applications, and medical technology. This shift towards model-based development naturally leads to changes in the verification and validation (V&V) process. The model validation problem determining that the model accurately captures the customer's high-level requirements has received little attention and the sufficiency of the validation activities has been largely determined through ad-hoc methods. Since the model serves as the central artifact, its correctness with respect to the users needs is absolutely crucial. In our investigation, we attempt to answer the following two questions with respect to validation (1) Are the requirements sufficiently defined for the system? and (2) How well does the model implement the behaviors specified by the requirements? The second question can be addressed using formal verification. Nevertheless, the size and complexity of many industrial systems make formal verification infeasible even if we have a formal model and formalized requirements. Thus, presently, there is no objective way of answering these two questions. To this end, we propose an approach based on testing that, when given a set of formal requirements, explores the relationship between requirements-based structural test-adequacy coverage and model-based structural test-adequacy coverage. The proposed technique uses requirements coverage metrics defined in [9] on formal high-level software requirements and existing model coverage metrics such as the Modified Condition and Decision Coverage (MC/DC) used when testing highly critical software in the avionics industry [8]. Our work is related to Chockler et al. [2], but we base our work on traditional testing techniques as opposed to verification techniques.

  16. 75 FR 5040 - Extension of Period for Comments on Enhancement in the Quality of Patents

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-01

    ... patents, to identify appropriate indicia of quality, and to establish metrics for the measurement of the... issued patents, to identify appropriate indicia of quality, and to establish metrics for the measurement.... Kappos, Under Secretary of Commerce for Intellectual Property and Director of the United States Patent...

  17. Monitoring and Discovery for Self-Organized Network Management in Virtualized and Software Defined Networks

    PubMed Central

    Valdivieso Caraguay, Ángel Leonardo; García Villalba, Luis Javier

    2017-01-01

    This paper presents the Monitoring and Discovery Framework of the Self-Organized Network Management in Virtualized and Software Defined Networks SELFNET project. This design takes into account the scalability and flexibility requirements needed by 5G infrastructures. In this context, the present framework focuses on gathering and storing the information (low-level metrics) related to physical and virtual devices, cloud environments, flow metrics, SDN traffic and sensors. Similarly, it provides the monitoring data as a generic information source in order to allow the correlation and aggregation tasks. Our design enables the collection and storing of information provided by all the underlying SELFNET sublayers, including the dynamically onboarded and instantiated SDN/NFV Apps, also known as SELFNET sensors. PMID:28362346

  18. Monitoring and Discovery for Self-Organized Network Management in Virtualized and Software Defined Networks.

    PubMed

    Caraguay, Ángel Leonardo Valdivieso; Villalba, Luis Javier García

    2017-03-31

    This paper presents the Monitoring and Discovery Framework of the Self-Organized Network Management in Virtualized and Software Defined Networks SELFNET project. This design takes into account the scalability and flexibility requirements needed by 5G infrastructures. In this context, the present framework focuses on gathering and storing the information (low-level metrics) related to physical and virtual devices, cloud environments, flow metrics, SDN traffic and sensors. Similarly, it provides the monitoring data as a generic information source in order to allow the correlation and aggregation tasks. Our design enables the collection and storing of information provided by all the underlying SELFNET sublayers, including the dynamically onboarded and instantiated SDN/NFV Apps, also known as SELFNET sensors.

  19. Measurement of the Inter-Rater Reliability Rate Is Mandatory for Improving the Quality of a Medical Database: Experience with the Paulista Lung Cancer Registry.

    PubMed

    Lauricella, Leticia L; Costa, Priscila B; Salati, Michele; Pego-Fernandes, Paulo M; Terra, Ricardo M

    2018-06-01

    Database quality measurement should be considered a mandatory step to ensure an adequate level of confidence in data used for research and quality improvement. Several metrics have been described in the literature, but no standardized approach has been established. We aimed to describe a methodological approach applied to measure the quality and inter-rater reliability of a regional multicentric thoracic surgical database (Paulista Lung Cancer Registry). Data from the first 3 years of the Paulista Lung Cancer Registry underwent an audit process with 3 metrics: completeness, consistency, and inter-rater reliability. The first 2 methods were applied to the whole data set, and the last method was calculated using 100 cases randomized for direct auditing. Inter-rater reliability was evaluated using percentage of agreement between the data collector and auditor and through calculation of Cohen's κ and intraclass correlation. The overall completeness per section ranged from 0.88 to 1.00, and the overall consistency was 0.96. Inter-rater reliability showed many variables with high disagreement (>10%). For numerical variables, intraclass correlation was a better metric than inter-rater reliability. Cohen's κ showed that most variables had moderate to substantial agreement. The methodological approach applied to the Paulista Lung Cancer Registry showed that completeness and consistency metrics did not sufficiently reflect the real quality status of a database. The inter-rater reliability associated with κ and intraclass correlation was a better quality metric than completeness and consistency metrics because it could determine the reliability of specific variables used in research or benchmark reports. This report can be a paradigm for future studies of data quality measurement. Copyright © 2018 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  20. An empirical comparison of a dynamic software testability metric to static cyclomatic complexity

    NASA Technical Reports Server (NTRS)

    Voas, Jeffrey M.; Miller, Keith W.; Payne, Jeffrey E.

    1993-01-01

    This paper compares the dynamic testability prediction technique termed 'sensitivity analysis' to the static testability technique termed cyclomatic complexity. The application that we chose in this empirical study is a CASE generated version of a B-737 autoland system. For the B-737 system we analyzed, we isolated those functions that we predict are more prone to hide errors during system/reliability testing. We also analyzed the code with several other well-known static metrics. This paper compares and contrasts the results of sensitivity analysis to the results of the static metrics.

  1. The Effect of Software Reusability on Information Theory Based Software Metrics

    DTIC Science & Technology

    1990-01-01

    of plans across programming languages and application areas, only a brief abstract treatment of non-contiguous "program parts" is mentioned in the...info->num = linenum; CA6 if(*info->text) W. if(find(linenum)) C.8 patchup(linenum, 1); /*fix up old line numbers*/ 107 C.9 if(*info->text) C-10 start

  2. Proposal to Develop Enhancements and Extensions of Formal Models for Risk Assessment In Software Projects

    DTIC Science & Technology

    2002-09-01

    seconds per minute that the runtime environment was up and running. Defect Categories. The labels of the 5 defect categories. 78 Cosmetic Defects...The name that corresponds to QSM’s cosmetic defects. Cosmetic defects can be described as deferred, such as errors in format of displays or...2002. [Fent00] Fenton , N. E. and Neil, M. Software Metrics: Roadmap. Proceedings of the Conference on the Future of Software Engineering, 2000, pp

  3. Using metrics to describe the participative stances of members within discussion forums.

    PubMed

    Jones, Ray; Sharkey, Siobhan; Smithson, Janet; Ford, Tamsin; Emmens, Tobit; Hewis, Elaine; Sheaves, Bryony; Owens, Christabel

    2011-01-10

    Researchers using forums and online focus groups need to ensure they are safe and need tools to make best use of the data. We explored the use of metrics that would allow better forum management and more effective analysis of participant contributions. To report retrospectively calculated metrics from self-harm discussion forums and to assess whether metrics add to other methods such as discourse analysis. We asked (1) which metrics are most useful to compare and manage forums, and (2) how metrics can be used to identify the participative stances of members to help manage discussion forums. We studied the use of metrics in discussion forums on self-harm. SharpTalk comprised five discussion forums, all using the same software but with different forum compositions. SharpTalk forums were similar to most moderated forums but combined support and general social chat with online focus groups discussing issues on self-harm. Routinely recorded time-stamp data were used to derive metrics of episodes, time online, pages read, and postings. We compared metrics from the forums with views from discussion threads and from moderators. We identified patterns of participants' online behavior by plotting scattergrams and identifying outliers and clusters within different metrics. In comparing forums, important metrics seem to be number of participants, number of active participants, total time of all participants logged on in each 24 hours, and total number of postings by all participants in 24 hours. In examining participative stances, the important metrics were individuals' time logged per 24 hours, number of episodes, mean length of episodes, number of postings per 24 hours, and location within the forum of those postings. Metric scattergrams identified several participative stances: (1) the "caretaker," who was "always around," logged on for a much greater time than most other participants, posting but mainly in response to others and rarely initiating threads, (2) the "butterfly," who "flitted in and out," had a large number of short episodes, (3) two "discussants," who initiated many more discussion threads than anybody else and posted proportionately less in the support room, (4) "here for you," who posted frequently in the support room in response to other participants' threads, and (5) seven "people in distress," who posted many comments in the support room in comparison with their total postings and tended to post on their own threads. Real-time metrics may be useful: (1) by offering additional ways of comparing different discussion forums helping with their management, and (2) by identifying participative stances of individuals so allowing better moderation and support of forums, and more effective use of the data collected. For this to happen, researchers need to publish metrics for their discussion forums and software developers need to offer more real-time metrics facilities.

  4. DSN Array Simulator

    NASA Technical Reports Server (NTRS)

    Tikidjian, Raffi; Mackey, Ryan

    2008-01-01

    The DSN Array Simulator (wherein 'DSN' signifies NASA's Deep Space Network) is an updated version of software previously denoted the DSN Receive Array Technology Assessment Simulation. This software (see figure) is used for computational modeling of a proposed DSN facility comprising user-defined arrays of antennas and transmitting and receiving equipment for microwave communication with spacecraft on interplanetary missions. The simulation includes variations in spacecraft tracked and communication demand changes for up to several decades of future operation. Such modeling is performed to estimate facility performance, evaluate requirements that govern facility design, and evaluate proposed improvements in hardware and/or software. The updated version of this software affords enhanced capability for characterizing facility performance against user-defined mission sets. The software includes a Monte Carlo simulation component that enables rapid generation of key mission-set metrics (e.g., numbers of links, data rates, and date volumes), and statistical distributions thereof as functions of time. The updated version also offers expanded capability for mixed-asset network modeling--for example, for running scenarios that involve user-definable mixtures of antennas having different diameters (in contradistinction to a fixed number of antennas having the same fixed diameter). The improved version also affords greater simulation fidelity, sufficient for validation by comparison with actual DSN operations and analytically predictable performance metrics.

  5. Measuring the distance between multiple sequence alignments.

    PubMed

    Blackburne, Benjamin P; Whelan, Simon

    2012-02-15

    Multiple sequence alignment (MSA) is a core method in bioinformatics. The accuracy of such alignments may influence the success of downstream analyses such as phylogenetic inference, protein structure prediction, and functional prediction. The importance of MSA has lead to the proliferation of MSA methods, with different objective functions and heuristics to search for the optimal MSA. Different methods of inferring MSAs produce different results in all but the most trivial cases. By measuring the differences between inferred alignments, we may be able to develop an understanding of how these differences (i) relate to the objective functions and heuristics used in MSA methods, and (ii) affect downstream analyses. We introduce four metrics to compare MSAs, which include the position in a sequence where a gap occurs or the location on a phylogenetic tree where an insertion or deletion (indel) event occurs. We use both real and synthetic data to explore the information given by these metrics and demonstrate how the different metrics in combination can yield more information about MSA methods and the differences between them. MetAl is a free software implementation of these metrics in Haskell. Source and binaries for Windows, Linux and Mac OS X are available from http://kumiho.smith.man.ac.uk/whelan/software/metal/.

  6. Multi-site study of diffusion metric variability: effects of site, vendor, field strength, and echo time on regions-of-interest and histogram-bin analyses.

    PubMed

    Helmer, K G; Chou, M-C; Preciado, R I; Gimi, B; Rollins, N K; Song, A; Turner, J; Mori, S

    2016-02-27

    It is now common for magnetic-resonance-imaging (MRI) based multi-site trials to include diffusion-weighted imaging (DWI) as part of the protocol. It is also common for these sites to possess MR scanners of different manufacturers, different software and hardware, and different software licenses. These differences mean that scanners may not be able to acquire data with the same number of gradient amplitude values and number of available gradient directions. Variability can also occur in achievable b-values and minimum echo times. The challenge of a multi-site study then, is to create a common protocol by understanding and then minimizing the effects of scanner variability and identifying reliable and accurate diffusion metrics. This study describes the effect of site, scanner vendor, field strength, and TE on two diffusion metrics: the first moment of the diffusion tensor field (mean diffusivity, MD), and the fractional anisotropy (FA) using two common analyses (region-of-interest and mean-bin value of whole brain histograms). The goal of the study was to identify sources of variability in diffusion-sensitized imaging and their influence on commonly reported metrics. The results demonstrate that the site, vendor, field strength, and echo time all contribute to variability in FA and MD, though to different extent. We conclude that characterization of the variability of DTI metrics due to site, vendor, field strength, and echo time is a worthwhile step in the construction of multi-center trials.

  7. Introducing an R-package for calculating channel width and other basic metrics for irregular river polygons

    NASA Astrophysics Data System (ADS)

    Golly, Antonius; Turowski, Jens

    2017-04-01

    The width of fluvial streams and channel beds is an important metric for a large number of hydraulic, geomorphic and ecologic applications. For example, for a given discharge the local channel width determines the water flow velocity and thus the sediment transport capacity of a reach. Since streams often have irregular shapes with uneven channel banks, the channel width strongly varies along the channel. Although, the geometry of streams or their beds can be measured easily in the field (e.g. with a Total Station or GPS) or from maps or aerial images in a GIS, the width of the stream cannot be identified objectively without further data processing, since the results are more or less irregular polygons with sometimes bended shapes. An objective quantification of the channel width and other metrics requires automated algorithms that are applicable over a range of channel shapes and spatial scales. Here, we present a lightweight software suite with a small number of functions that process 2D or 3D geometrical data of channels or channel beds. The software, written as an R-package, accepts various text data formats and can be configured through five parameters. It creates interactive overview plots (if desired) and produces three basic channel metrics: the centerline, the channel width along the centerline and the slope along the centerline. The centerline is an optimized line that minimizes the distances to both channel banks. This centerline gives also a measure for the real length and slope of the channel. From this centerline perpendicular transects are generated which allow for the calculation of the channel width where they intersect with the channel banks. Briefly, we present an example and demonstrate the importance of these metrics in a use case of a steep stream, the Erlenbach stream in Switzerland. We were motivated to develop and publish the algorithm in an open-source framework, since only proprietary solutions were available at that time. The software is developed in R and is published under GNU GPL meaning it is free to use, edit and copy. This makes the software available also to users who do not own a MATLAB or ARCMAP license for which similar products exist.

  8. StakeMeter: value-based stakeholder identification and quantification framework for value-based software systems.

    PubMed

    Babar, Muhammad Imran; Ghazali, Masitah; Jawawi, Dayang N A; Bin Zaheer, Kashif

    2015-01-01

    Value-based requirements engineering plays a vital role in the development of value-based software (VBS). Stakeholders are the key players in the requirements engineering process, and the selection of critical stakeholders for the VBS systems is highly desirable. Based on the stakeholder requirements, the innovative or value-based idea is realized. The quality of the VBS system is associated with the concrete set of valuable requirements, and the valuable requirements can only be obtained if all the relevant valuable stakeholders participate in the requirements elicitation phase. The existing value-based approaches focus on the design of the VBS systems. However, the focus on the valuable stakeholders and requirements is inadequate. The current stakeholder identification and quantification (SIQ) approaches are neither state-of-the-art nor systematic for the VBS systems. The existing approaches are time-consuming, complex and inconsistent which makes the initiation process difficult. Moreover, the main motivation of this research is that the existing SIQ approaches do not provide the low level implementation details for SIQ initiation and stakeholder metrics for quantification. Hence, keeping in view the existing SIQ problems, this research contributes in the form of a new SIQ framework called 'StakeMeter'. The StakeMeter framework is verified and validated through case studies. The proposed framework provides low-level implementation guidelines, attributes, metrics, quantification criteria and application procedure as compared to the other methods. The proposed framework solves the issues of stakeholder quantification or prioritization, higher time consumption, complexity, and process initiation. The framework helps in the selection of highly critical stakeholders for the VBS systems with less judgmental error.

  9. Software metrics: The quantitative impact of four factors on work rates experienced during software development. [reliability engineering

    NASA Technical Reports Server (NTRS)

    Gaffney, J. E., Jr.; Judge, R. W.

    1981-01-01

    A model of a software development process is described. The software development process is seen to consist of a sequence of activities, such as 'program design' and 'module development' (or coding). A manpower estimate is made by multiplying code size by the rates (man months per thousand lines of code) for each of the activities relevant to the particular case of interest and summing up the results. The effect of four objectively determinable factors (organization, software product type, computer type, and code type) on productivity values for each of nine principal software development activities was assessed. Four factors were identified which account for 39% of the observed productivity variation.

  10. Historical assessments and comparisons of benthic communities and physical habitat in two agricultural streams in California's San Joaquin watershed.

    PubMed

    Hall, Lenwood W; Killen, William D

    2006-01-01

    This study was designed to assess trends in physical habitat and benthic communities (macroinvertebrates) annually in two agricultural streams (Del Puerto Creek and Salt Slough) in California's San Joaquin Valley from 2001 to 2005, determine the relationship between benthic communities and both water quality and physical habitat from both streams over the 5-year period, and compare benthic communities and physical habitat in both streams from 2001 to 2005. Physical habitat, measured with 10 metrics and a total score, was reported to be fairly stable over 5 years in Del Puerto Creek but somewhat variable in Salt Slough. Benthic communities, measured with 18 metrics, were reported to be marginally variable over time in Del Puerto Creek but fairly stable in Salt Slough. Rank correlation analysis for both water bodies combined showed that channel alteration, embeddedness, riparian buffer, and velocity/depth/diversity were the most important physical habitat metrics influencing the various benthic metrics. Correlations of water quality parameters and benthic community metrics for both water bodies combined showed that turbidity, dissolved oxygen, and conductivity were the most important water quality parameters influencing the different benthic metrics. A comparison of physical habitat metrics (including total score) for both water bodies over the 5-year period showed that habitat metrics were more positive in Del Puerto Creek when compared to Salt Slough. A comparison of benthic metrics in both water bodies showed that approximately one-third of the metrics were significantly different between the two water bodies. Generally, the more positive benthic metric scores were reported in Del Puerto Creek, which suggests that the communities in this creek are more robust than Salt Slough.

  11. NeuronMetrics: software for semi-automated processing of cultured neuron images.

    PubMed

    Narro, Martha L; Yang, Fan; Kraft, Robert; Wenk, Carola; Efrat, Alon; Restifo, Linda L

    2007-03-23

    Using primary cell culture to screen for changes in neuronal morphology requires specialized analysis software. We developed NeuronMetrics for semi-automated, quantitative analysis of two-dimensional (2D) images of fluorescently labeled cultured neurons. It skeletonizes the neuron image using two complementary image-processing techniques, capturing fine terminal neurites with high fidelity. An algorithm was devised to span wide gaps in the skeleton. NeuronMetrics uses a novel strategy based on geometric features called faces to extract a branch number estimate from complex arbors with numerous neurite-to-neurite contacts, without creating a precise, contact-free representation of the neurite arbor. It estimates total neurite length, branch number, primary neurite number, territory (the area of the convex polygon bounding the skeleton and cell body), and Polarity Index (a measure of neuronal polarity). These parameters provide fundamental information about the size and shape of neurite arbors, which are critical factors for neuronal function. NeuronMetrics streamlines optional manual tasks such as removing noise, isolating the largest primary neurite, and correcting length for self-fasciculating neurites. Numeric data are output in a single text file, readily imported into other applications for further analysis. Written as modules for ImageJ, NeuronMetrics provides practical analysis tools that are easy to use and support batch processing. Depending on the need for manual intervention, processing time for a batch of approximately 60 2D images is 1.0-2.5 h, from a folder of images to a table of numeric data. NeuronMetrics' output accelerates the quantitative detection of mutations and chemical compounds that alter neurite morphology in vitro, and will contribute to the use of cultured neurons for drug discovery.

  12. Quality of Information Approach to Improving Source Selection in Tactical Networks

    DTIC Science & Technology

    2017-02-01

    consider the performance of this process based on metrics relating to quality of information: accuracy, timeliness, completeness and reliability. These...that are indicators of that the network is meeting these quality requirements. We study effective data rate, social distance, link integrity and the...utility of information as metrics within a multi-genre network to determine the quality of information of its available sources. This paper proposes a

  13. A Methodology for Writing High Quality Requirement Specifications and for Evaluating Existing Ones

    NASA Technical Reports Server (NTRS)

    Rosenberg, Linda; Hammer, Theodore

    1999-01-01

    Requirements development and management have always been critical in the implementation of software systems-engineers are unable to build what analysts can not define. It is generally accepted that the earlier in the life cycle potential risks are identified the easier it is to eliminate or manage the conditions that introduce that risk. Problems that are not found until testing are approximately 14 times more costly to fix than if the problem was found in the requirement phase. The requirements specification, as the first tangible representation of the capability to be produced, establishes the basis for all of the project's engineering management and assurance functions. If the quality of the requirements specification is poor it can give rise to risks in all areas of the project. Recently, automated tools have become available to support requirements management. The use of these tools not only provides support in the definition and tracing of requirements, but it also opens the door to effective use of metrics in characterizing and assessing the quality of the requirement specifications.

  14. A Methodology for Writing High Quality Requirements Specification and Evaluating Existing Ones

    NASA Technical Reports Server (NTRS)

    Rosenberg, Linda; Hammer, Theodore

    1999-01-01

    Requirements development and management have always been critical in the implementation of software systems; engineers are unable to build what analysts can't define. It is generally accepted that the earlier in the life cycle potential risks are identified the easier it is to eliminate or manage the conditions that introduce that risk. Problems that are not found until testing are approximately 14 times more costly to fix than if the problem was found in the requirement phase. The requirements specification, as the first tangible representation of the capability to be produced, establishes the basis for all of the project's engineering management and assurance functions. If the quality of the requirements specification is poor it can give rise to risks in all areas of the project. Recently, automated tools have become available to support requirements management. The use of these tools not only provides support in the definition and tracing of requirements, but it also opens the door to effective use of metrics in characterizing and assessing the quality of the requirement specifications.

  15. QUAST: quality assessment tool for genome assemblies

    PubMed Central

    Gurevich, Alexey; Saveliev, Vladislav; Vyahhi, Nikolay; Tesler, Glenn

    2013-01-01

    Summary: Limitations of genome sequencing techniques have led to dozens of assembly algorithms, none of which is perfect. A number of methods for comparing assemblers have been developed, but none is yet a recognized benchmark. Further, most existing methods for comparing assemblies are only applicable to new assemblies of finished genomes; the problem of evaluating assemblies of previously unsequenced species has not been adequately considered. Here, we present QUAST—a quality assessment tool for evaluating and comparing genome assemblies. This tool improves on leading assembly comparison software with new ideas and quality metrics. QUAST can evaluate assemblies both with a reference genome, as well as without a reference. QUAST produces many reports, summary tables and plots to help scientists in their research and in their publications. In this study, we used QUAST to compare several genome assemblers on three datasets. QUAST tables and plots for all of them are available in the Supplementary Material, and interactive versions of these reports are on the QUAST website. Availability: http://bioinf.spbau.ru/quast Contact: gurevich@bioinf.spbau.ru Supplementary information: Supplementary data are available at Bioinformatics online. PMID:23422339

  16. Deriving principal channel metrics from bank and long-profile geometry with the R package cmgo

    NASA Astrophysics Data System (ADS)

    Golly, Antonius; Turowski, Jens M.

    2017-09-01

    Landscape patterns result from landscape forming processes. This link can be exploited in geomorphological research by reversely analyzing the geometrical content of landscapes to develop or confirm theories of the underlying processes. Since rivers represent a dominant control on landscape formation, there is a particular interest in examining channel metrics in a quantitative and objective manner. For example, river cross-section geometry is required to model local flow hydraulics, which in turn determine erosion and thus channel dynamics. Similarly, channel geometry is crucial for engineering purposes, water resource management, and ecological restoration efforts. These applications require a framework to capture and derive the data. In this paper we present an open-source software tool that performs the calculation of several channel metrics (length, slope, width, bank retreat, knickpoints, etc.) in an objective and reproducible way based on principal bank geometry that can be measured in the field or in a GIS. Furthermore, the software provides a framework to integrate spatial features, for example the abundance of species or the occurrence of knickpoints. The program is available at https://github.com/AntoniusGolly/cmgo and is free to use, modify, and redistribute under the terms of the GNU General Public License version 3 as published by the Free Software Foundation.

  17. PSQM-based RR and NR video quality metrics

    NASA Astrophysics Data System (ADS)

    Lu, Zhongkang; Lin, Weisi; Ong, Eeping; Yang, Xiaokang; Yao, Susu

    2003-06-01

    This paper presents a new and general concept, PQSM (Perceptual Quality Significance Map), to be used in measuring the visual distortion. It makes use of the selectivity characteristic of HVS (Human Visual System) that it pays more attention to certain area/regions of visual signal due to one or more of the following factors: salient features in image/video, cues from domain knowledge, and association of other media (e.g., speech or audio). PQSM is an array whose elements represent the relative perceptual-quality significance levels for the corresponding area/regions for images or video. Due to its generality, PQSM can be incorporated into any visual distortion metrics: to improve effectiveness or/and efficiency of perceptual metrics; or even to enhance a PSNR-based metric. A three-stage PQSM estimation method is also proposed in this paper, with an implementation of motion, texture, luminance, skin-color and face mapping. Experimental results show the scheme can improve the performance of current image/video distortion metrics.

  18. Spread spectrum image watermarking based on perceptual quality metric.

    PubMed

    Zhang, Fan; Liu, Wenyu; Lin, Weisi; Ngan, King Ngi

    2011-11-01

    Efficient image watermarking calls for full exploitation of the perceptual distortion constraint. Second-order statistics of visual stimuli are regarded as critical features for perception. This paper proposes a second-order statistics (SOS)-based image quality metric, which considers the texture masking effect and the contrast sensitivity in Karhunen-Loève transform domain. Compared with the state-of-the-art metrics, the quality prediction by SOS better correlates with several subjectively rated image databases, in which the images are impaired by the typical coding and watermarking artifacts. With the explicit metric definition, spread spectrum watermarking is posed as an optimization problem: we search for a watermark to minimize the distortion of the watermarked image and to maximize the correlation between the watermark pattern and the spread spectrum carrier. The simple metric guarantees the optimal watermark a closed-form solution and a fast implementation. The experiments show that the proposed watermarking scheme can take full advantage of the distortion constraint and improve the robustness in return.

  19. "Can you see me now?" An objective metric for predicting intelligibility of compressed American Sign Language video

    NASA Astrophysics Data System (ADS)

    Ciaramello, Francis M.; Hemami, Sheila S.

    2007-02-01

    For members of the Deaf Community in the United States, current communication tools include TTY/TTD services, video relay services, and text-based communication. With the growth of cellular technology, mobile sign language conversations are becoming a possibility. Proper coding techniques must be employed to compress American Sign Language (ASL) video for low-rate transmission while maintaining the quality of the conversation. In order to evaluate these techniques, an appropriate quality metric is needed. This paper demonstrates that traditional video quality metrics, such as PSNR, fail to predict subjective intelligibility scores. By considering the unique structure of ASL video, an appropriate objective metric is developed. Face and hand segmentation is performed using skin-color detection techniques. The distortions in the face and hand regions are optimally weighted and pooled across all frames to create an objective intelligibility score for a distorted sequence. The objective intelligibility metric performs significantly better than PSNR in terms of correlation with subjective responses.

  20. SU-F-BRB-07: A Plan Comparison Tool to Ensure Robustness and Deliverability in Online-Adaptive Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hill, P; Labby, Z; Bayliss, R A

    Purpose: To develop a plan comparison tool that will ensure robustness and deliverability through analysis of baseline and online-adaptive radiotherapy plans using similarity metrics. Methods: The ViewRay MRIdian treatment planning system allows export of a plan file that contains plan and delivery information. A software tool was developed to read and compare two plans, providing information and metrics to assess their similarity. In addition to performing direct comparisons (e.g. demographics, ROI volumes, number of segments, total beam-on time), the tool computes and presents histograms of derived metrics (e.g. step-and-shoot segment field sizes, segment average leaf gaps). Such metrics were investigatedmore » for their ability to predict that an online-adapted plan reasonably similar to a baseline plan where deliverability has already been established. Results: In the realm of online-adaptive planning, comparing ROI volumes offers a sanity check to verify observations found during contouring. Beyond ROI analysis, it has been found that simply editing contours and re-optimizing to adapt treatment can produce a delivery that is substantially different than the baseline plan (e.g. number of segments increased by 31%), with no changes in optimization parameters and only minor changes in anatomy. Currently the tool can quickly identify large omissions or deviations from baseline expectations. As our online-adaptive patient population increases, we will continue to develop and refine quantitative acceptance criteria for adapted plans and relate them historical delivery QA measurements. Conclusion: The plan comparison tool is in clinical use and reports a wide range of comparison metrics, illustrating key differences between two plans. This independent check is accomplished in seconds and can be performed in parallel to other tasks in the online-adaptive workflow. Current use prevents large planning or delivery errors from occurring, and ongoing refinements will lead to increased assurance of plan quality.« less

  1. Measuring the impact of pharmacoepidemiologic research using altmetrics: A case study of a CNODES drug-safety article.

    PubMed

    Gamble, J M; Traynor, Robyn L; Gruzd, Anatoliy; Mai, Philip; Dormuth, Colin R; Sketris, Ingrid S

    2018-03-24

    To provide an overview of altmetrics, including their potential benefits and limitations, how they may be obtained, and their role in assessing pharmacoepidemiologic research impact. Our review was informed by compiling relevant literature identified through searching multiple health research databases (PubMed, Embase, and CIHNAHL) and grey literature sources (websites, blogs, and reports). We demonstrate how pharmacoepidemiologists, in particular, may use altmetrics to understand scholarly impact and knowledge translation by providing a case study of a drug-safety study conducted by the Canadian Network of Observational Drug Effect Studies. A common approach to measuring research impact is the use of citation-based metrics, such as an article's citation count or a journal's impact factor. "Alternative" metrics, or altmetrics, are increasingly supported as a complementary measure of research uptake in the age of social media. Altmetrics are nontraditional indicators that capture a diverse set of traceable, online research-related artifacts including peer-reviewed publications and other research outputs (software, datasets, blogs, videos, posters, policy documents, presentations, social media posts, wiki entries, etc). Compared with traditional citation-based metrics, altmetrics take a more holistic view of research impact, attempting to capture the activity and engagement of both scholarly and nonscholarly communities. Despite the limited theoretical underpinnings, possible commercial influence, potential for gaming and manipulation, and numerous data quality-related issues, altmetrics are promising as a supplement to more traditional citation-based metrics because they can ingest and process a larger set of data points related to the flow and reach of scholarly communication from an expanded pool of stakeholders. Unlike citation-based metrics, altmetrics are not inherently rooted in the research publication process, which includes peer review; it is unclear to what extent they should be used for research evaluation. © 2018 The Authors. Pharmacoepidemiology and Drug Safety. Published by John Wiley & Sons, Ltd.

  2. KCNSC Automated RAIL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Branson, Donald

    The KCNSC Automated RAIL (Rolling Action Item List) system provides an electronic platform to manage and escalate rolling action items within an business and manufacturing environment at Honeywell. The software enables a tiered approach to issue management where issues are escalated up a management chain based on team input and compared to business metrics. The software manages action items at different levels of the organization and allows all users to discuss action items concurrently. In addition, the software drives accountability through timely emails and proper visibility during team meetings.

  3. Developing a set of consensus indicators to support maternity service quality improvement: using Core Outcome Set methodology including a Delphi process.

    PubMed

    Bunch, K J; Allin, B; Jolly, M; Hardie, T; Knight, M

    2018-05-16

    To develop a core metric set to monitor the quality of maternity care. Delphi process followed by a face-to-face consensus meeting. English maternity units. Three representative expert panels: service designers, providers and users. Maternity care metrics judged important by participants. Participants were asked to complete a two-phase Delphi process, scoring metrics from existing local maternity dashboards. A consensus meeting discussed the results and re-scored the metrics. In all, 125 distinct metrics across six domains were identified from existing dashboards. Following the consensus meeting, 14 metrics met the inclusion criteria for the final core set: smoking rate at booking; rate of birth without intervention; caesarean section delivery rate in Robson group 1 women; caesarean section delivery rate in Robson group 2 women; caesarean section delivery rate in Robson group 5 women; third- and fourth-degree tear rate among women delivering vaginally; rate of postpartum haemorrhage of ≥1500 ml; rate of successful vaginal birth after a single previous caesarean section; smoking rate at delivery; proportion of babies born at term with an Apgar score <7 at 5 minutes; proportion of babies born at term admitted to the neonatal intensive care unit; proportion of babies readmitted to hospital at <30 days of age; breastfeeding initiation rate; and breastfeeding rate at 6-8 weeks. Core outcome set methodology can be used to incorporate the views of key stakeholders in developing a core metric set to monitor the quality of care in maternity units, thus enabling improvement. Achieving consensus on core metrics for monitoring the quality of maternity care. © 2018 The Authors. BJOG: An International Journal of Obstetrics and Gynaecology published by John Wiley & Sons Ltd on behalf of Royal College of Obstetricians and Gynaecologists.

  4. Seismic Data Archive Quality Assurance -- Analytics Adding Value at Scale

    NASA Astrophysics Data System (ADS)

    Casey, R. E.; Ahern, T. K.; Sharer, G.; Templeton, M. E.; Weertman, B.; Keyson, L.

    2015-12-01

    Since the emergence of real-time delivery of seismic data over the last two decades, solutions for near-real-time quality analysis and station monitoring have been developed by data producers and data stewards. This has allowed for a nearly constant awareness of the quality of the incoming data and the general health of the instrumentation around the time of data capture. Modern quality assurance systems are evolving to provide ready access to a large variety of metrics, a rich and self-correcting history of measurements, and more importantly the ability to access these quality measurements en-masse through a programmatic interface.The MUSTANG project at the IRIS Data Management Center is working to achieve 'total archival data quality', where a large number of standardized metrics, some computationally expensive, are generated and stored for all data from decades past to the near present. To perform this on a 300 TB archive of compressed time series requires considerable resources in network I/O, disk storage, and CPU capacity to achieve scalability, not to mention the technical expertise to develop and maintain it. In addition, staff scientists are necessary to develop the system metrics and employ them to produce comprehensive and timely data quality reports to assist seismic network operators in maintaining their instrumentation. All of these metrics must be available to the scientist 24/7.We will present an overview of the MUSTANG architecture including the development of its standardized metrics code in R. We will show examples of the metrics values that we make publicly available to scientists and educators and show how we are sharing the algorithms used. We will also discuss the development of a capability that will enable scientific researchers to specify data quality constraints on their requests for data, providing only the data that is best suited to their area of study.

  5. The National Library of Medicine Pill Image Recognition Challenge: An Initial Report.

    PubMed

    Yaniv, Ziv; Faruque, Jessica; Howe, Sally; Dunn, Kathel; Sharlip, David; Bond, Andrew; Perillan, Pablo; Bodenreider, Olivier; Ackerman, Michael J; Yoo, Terry S

    2016-10-01

    In January 2016 the U.S. National Library of Medicine announced a challenge competition calling for the development and discovery of high-quality algorithms and software that rank how well consumer images of prescription pills match reference images of pills in its authoritative RxIMAGE collection. This challenge was motivated by the need to easily identify unknown prescription pills both by healthcare personnel and the general public. Potential benefits of this capability include confirmation of the pill in settings where the documentation and medication have been separated, such as in a disaster or emergency; and confirmation of a pill when the prescribed medication changes from brand to generic, or for any other reason the shape and color of the pill change. The data for the competition consisted of two types of images, high quality macro photographs, reference images, and consumer quality photographs of the quality we expect users of a proposed application to acquire. A training dataset consisting of 2000 reference images and 5000 corresponding consumer quality images acquired from 1000 pills was provided to challenge participants. A second dataset acquired from 1000 pills with similar distributions of shape and color was reserved as a segregated testing set. Challenge submissions were required to produce a ranking of the reference images, given a consumer quality image as input. Determination of the winning teams was done using the mean average precision quality metric, with the three winners obtaining mean average precision scores of 0.27, 0.09, and 0.08. In the retrieval results, the correct image was amongst the top five ranked images 43%, 12%, and 11% of the time, out of 5000 query/consumer images. This is an initial promising step towards development of an NLM software system and application-programming interface facilitating pill identification. The training dataset will continue to be freely available online at: http://pir.nlm.nih.gov/challenge/submission.html.

  6. Implementing the Data Center Energy Productivity Metric in a High Performance Computing Data Center

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sego, Landon H.; Marquez, Andres; Rawson, Andrew

    2013-06-30

    As data centers proliferate in size and number, the improvement of their energy efficiency and productivity has become an economic and environmental imperative. Making these improvements requires metrics that are robust, interpretable, and practical. We discuss the properties of a number of the proposed metrics of energy efficiency and productivity. In particular, we focus on the Data Center Energy Productivity (DCeP) metric, which is the ratio of useful work produced by the data center to the energy consumed performing that work. We describe our approach for using DCeP as the principal outcome of a designed experiment using a highly instrumented,more » high-performance computing data center. We found that DCeP was successful in clearly distinguishing different operational states in the data center, thereby validating its utility as a metric for identifying configurations of hardware and software that would improve energy productivity. We also discuss some of the challenges and benefits associated with implementing the DCeP metric, and we examine the efficacy of the metric in making comparisons within a data center and between data centers.« less

  7. A Validation of Object-Oriented Design Metrics

    NASA Technical Reports Server (NTRS)

    Basili, Victor R.; Briand, Lionel; Melo, Walcelio L.

    1995-01-01

    This paper presents the results of a study conducted at the University of Maryland in which we experimentally investigated the suite of Object-Oriented (00) design metrics introduced by [Chidamber and Kemerer, 1994]. In order to do this, we assessed these metrics as predictors of fault-prone classes. This study is complementary to [Lieand Henry, 1993] where the same suite of metrics had been used to assess frequencies of maintenance changes to classes. To perform our validation accurately, we collected data on the development of eight medium-sized information management systems based on identical requirements. All eight projects were developed using a sequential life cycle model, a well-known 00 analysis/design method and the C++ programming language. Based on experimental results, the advantages and drawbacks of these 00 metrics are discussed and suggestions for improvement are provided. Several of Chidamber and Kemerer's 00 metrics appear to be adequate to predict class fault-proneness during the early phases of the life-cycle. We also showed that they are, on our data set, better predictors than "traditional" code metrics, which can only be collected at a later phase of the software development processes.

  8. Sandia National Laboratories Advanced Simulation and Computing (ASC) software quality plan. Part 1 : ASC software quality engineering practices version 1.0.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Minana, Molly A.; Sturtevant, Judith E.; Heaphy, Robert

    2005-01-01

    The purpose of the Sandia National Laboratories (SNL) Advanced Simulation and Computing (ASC) Software Quality Plan is to clearly identify the practices that are the basis for continually improving the quality of ASC software products. Quality is defined in DOE/AL Quality Criteria (QC-1) as conformance to customer requirements and expectations. This quality plan defines the ASC program software quality practices and provides mappings of these practices to the SNL Corporate Process Requirements (CPR 1.3.2 and CPR 1.3.6) and the Department of Energy (DOE) document, ASCI Software Quality Engineering: Goals, Principles, and Guidelines (GP&G). This quality plan identifies ASC management andmore » software project teams' responsibilities for cost-effective software engineering quality practices. The SNL ASC Software Quality Plan establishes the signatories commitment to improving software products by applying cost-effective software engineering quality practices. This document explains the project teams opportunities for tailoring and implementing the practices; enumerates the practices that compose the development of SNL ASC's software products; and includes a sample assessment checklist that was developed based upon the practices in this document.« less

  9. A Software Application for Assessing Readability in the Japanese EFL Context

    ERIC Educational Resources Information Center

    Ozasa, Toshiaki; Weir, George R. S.; Fukui, Masayasu

    2010-01-01

    We have been engaged in developing a readability index and its application software attuned for Japanese EFL learners. The index program, Ozasa-Fukui Year Level Program, Ver. 1.0, was used in developing the readability metric Ozasa-Fukui Year Level Index but tended to assume a high level of computer knowledge in its users. As a result, the…

  10. PuLP/XtraPuLP : Partitioning Tools for Extreme-Scale Graphs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Slota, George M; Rajamanickam, Sivasankaran; Madduri, Kamesh

    2017-09-21

    PuLP/XtraPulp is software for partitioning graphs from several real-world problems. Graphs occur in several places in real world from road networks, social networks and scientific simulations. For efficient parallel processing these graphs have to be partitioned (split) with respect to metrics such as computation and communication costs. Our software allows such partitioning for massive graphs.

  11. Sandia National Laboratories Advanced Simulation and Computing (ASC) software quality plan : ASC software quality engineering practices Version 3.0.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Turgeon, Jennifer L.; Minana, Molly A.; Hackney, Patricia

    2009-01-01

    The purpose of the Sandia National Laboratories (SNL) Advanced Simulation and Computing (ASC) Software Quality Plan is to clearly identify the practices that are the basis for continually improving the quality of ASC software products. Quality is defined in the US Department of Energy/National Nuclear Security Agency (DOE/NNSA) Quality Criteria, Revision 10 (QC-1) as 'conformance to customer requirements and expectations'. This quality plan defines the SNL ASC Program software quality engineering (SQE) practices and provides a mapping of these practices to the SNL Corporate Process Requirement (CPR) 001.3.6; 'Corporate Software Engineering Excellence'. This plan also identifies ASC management's and themore » software project teams responsibilities in implementing the software quality practices and in assessing progress towards achieving their software quality goals. This SNL ASC Software Quality Plan establishes the signatories commitments to improving software products by applying cost-effective SQE practices. This plan enumerates the SQE practices that comprise the development of SNL ASC's software products and explains the project teams opportunities for tailoring and implementing the practices.« less

  12. Sandia National Laboratories Advanced Simulation and Computing (ASC) software quality plan. Part 1: ASC software quality engineering practices, Version 2.0.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sturtevant, Judith E.; Heaphy, Robert; Hodges, Ann Louise

    2006-09-01

    The purpose of the Sandia National Laboratories Advanced Simulation and Computing (ASC) Software Quality Plan is to clearly identify the practices that are the basis for continually improving the quality of ASC software products. The plan defines the ASC program software quality practices and provides mappings of these practices to Sandia Corporate Requirements CPR 1.3.2 and 1.3.6 and to a Department of Energy document, ASCI Software Quality Engineering: Goals, Principles, and Guidelines. This document also identifies ASC management and software project teams responsibilities in implementing the software quality practices and in assessing progress towards achieving their software quality goals.

  13. Online Planning Algorithm

    NASA Technical Reports Server (NTRS)

    Rabideau, Gregg R.; Chien, Steve A.

    2010-01-01

    AVA v2 software selects goals for execution from a set of goals that oversubscribe shared resources. The term goal refers to a science or engineering request to execute a possibly complex command sequence, such as image targets or ground-station downlinks. Developed as an extension to the Virtual Machine Language (VML) execution system, the software enables onboard and remote goal triggering through the use of an embedded, dynamic goal set that can oversubscribe resources. From the set of conflicting goals, a subset must be chosen that maximizes a given quality metric, which in this case is strict priority selection. A goal can never be pre-empted by a lower priority goal, and high-level goals can be added, removed, or updated at any time, and the "best" goals will be selected for execution. The software addresses the issue of re-planning that must be performed in a short time frame by the embedded system where computational resources are constrained. In particular, the algorithm addresses problems with well-defined goal requests without temporal flexibility that oversubscribes available resources. By using a fast, incremental algorithm, goal selection can be postponed in a "just-in-time" fashion allowing requests to be changed or added at the last minute. Thereby enabling shorter response times and greater autonomy for the system under control.

  14. Comparison of macroinvertebrate-derived stream quality metrics between snag and riffle habitats

    USGS Publications Warehouse

    Stepenuck, K.F.; Crunkilton, R.L.; Bozek, Michael A.; Wang, L.

    2008-01-01

    We compared benthic macroinvertebrate assemblage structure at snag and riffle habitats in 43 Wisconsin streams across a range of watershed urbanization using a variety of stream quality metrics. Discriminant analysis indicated that dominant taxa at riffles and snags differed; Hydropsychid caddisflies (Hydropsyche betteni and Cheumatopsyche spp.) and elmid beetles (Optioservus spp. and Stenemlis spp.) typified riffles, whereas isopods (Asellus intermedius) and amphipods (Hyalella azteca and Gammarus pseudolimnaeus) predominated in snags. Analysis of covariance indicated that samples from snag and riffle habitats differed significantly in their response to the urbanization gradient for the Hilsenhoff biotic index (BI), Shannon's diversity index, and percent of filterers, shredders, and pollution intolerant Ephemeroptera, Plecoptera, and Trichoptera (EPT) at each stream site (p ??? 0.10). These differences suggest that although macroinvertebrate assemblages present in either habitat type are sensitive to detecting the effects of urbanization, metrics derived from different habitats should not be intermixed when assessing stream quality through biomonitoring. This can be a limitation to resource managers who wish to compare water quality among streams where the same habitat type is not available at all stream locations, or where a specific habitat type (i.e., a riffle) is required to determine a metric value (i.e., BI). To account for differences in stream quality at sites lacking riffle habitat, snag-derived metric values can be adjusted based on those obtained from riffles that have been exposed to the same level of urbanization. Comparison of nonlinear regression equations that related stream quality metric values from the two habitat types to percent watershed urbanization indicated that snag habitats had on average 30.2 fewer percent EPT individuals, a lower diversity index value than riffles, and a BI value of 0.29 greater than riffles. ?? 2008 American Water Resources Association.

  15. jqcML: an open-source java API for mass spectrometry quality control data in the qcML format.

    PubMed

    Bittremieux, Wout; Kelchtermans, Pieter; Valkenborg, Dirk; Martens, Lennart; Laukens, Kris

    2014-07-03

    The awareness that systematic quality control is an essential factor to enable the growth of proteomics into a mature analytical discipline has increased over the past few years. To this aim, a controlled vocabulary and document structure have recently been proposed by Walzer et al. to store and disseminate quality-control metrics for mass-spectrometry-based proteomics experiments, called qcML. To facilitate the adoption of this standardized quality control routine, we introduce jqcML, a Java application programming interface (API) for the qcML data format. First, jqcML provides a complete object model to represent qcML data. Second, jqcML provides the ability to read, write, and work in a uniform manner with qcML data from different sources, including the XML-based qcML file format and the relational database qcDB. Interaction with the XML-based file format is obtained through the Java Architecture for XML Binding (JAXB), while generic database functionality is obtained by the Java Persistence API (JPA). jqcML is released as open-source software under the permissive Apache 2.0 license and can be downloaded from https://bitbucket.org/proteinspector/jqcml .

  16. Developing a more useful surface quality metric for laser optics

    NASA Astrophysics Data System (ADS)

    Turchette, Quentin; Turner, Trey

    2011-02-01

    Light scatter due to surface defects on laser resonator optics produces losses which lower system efficiency and output power. The traditional methodology for surface quality inspection involves visual comparison of a component to scratch and dig (SAD) standards under controlled lighting and viewing conditions. Unfortunately, this process is subjective and operator dependent. Also, there is no clear correlation between inspection results and the actual performance impact of the optic in a laser resonator. As a result, laser manufacturers often overspecify surface quality in order to ensure that optics will not degrade laser performance due to scatter. This can drive up component costs and lengthen lead times. Alternatively, an objective test system for measuring optical scatter from defects can be constructed with a microscope, calibrated lighting, a CCD detector and image processing software. This approach is quantitative, highly repeatable and totally operator independent. Furthermore, it is flexible, allowing the user to set threshold levels as to what will or will not constitute a defect. This paper details how this automated, quantitative type of surface quality measurement can be constructed, and shows how its results correlate against conventional loss measurement techniques such as cavity ringdown times.

  17. The accurate assessment of small-angle X-ray scattering data

    DOE PAGES

    Grant, Thomas D.; Luft, Joseph R.; Carter, Lester G.; ...

    2015-01-23

    Small-angle X-ray scattering (SAXS) has grown in popularity in recent times with the advent of bright synchrotron X-ray sources, powerful computational resources and algorithms enabling the calculation of increasingly complex models. However, the lack of standardized data-quality metrics presents difficulties for the growing user community in accurately assessing the quality of experimental SAXS data. Here, a series of metrics to quantitatively describe SAXS data in an objective manner using statistical evaluations are defined. These metrics are applied to identify the effects of radiation damage, concentration dependence and interparticle interactions on SAXS data from a set of 27 previously described targetsmore » for which high-resolution structures have been determined via X-ray crystallography or nuclear magnetic resonance (NMR) spectroscopy. Studies show that these metrics are sufficient to characterize SAXS data quality on a small sample set with statistical rigor and sensitivity similar to or better than manual analysis. The development of data-quality analysis strategies such as these initial efforts is needed to enable the accurate and unbiased assessment of SAXS data quality.« less

  18. miniTri Mantevo miniapp v. 1.0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berry, Johathan; Stark, Dylan; Wolf, Michael

    2016-02-02

    miniTri is a miniapplication developed as part of the Mantevo project. Given a graph, miniTri enumerates all triangles in this graph and computes a metric for each triangle based on the triangle edge and vertex degree. The output of miniTri is a summary of this metric. miniTri mimics the computational requirements of an important set of data science applications. Several approaches to this problem are included in the miniTri software.

  19. An Architecture, System Engineering, and Acquisition Approach for Space System Software Resiliency

    NASA Astrophysics Data System (ADS)

    Phillips, Dewanne Marie

    Software intensive space systems can harbor defects and vulnerabilities that may enable external adversaries or malicious insiders to disrupt or disable system functions, risking mission compromise or loss. Mitigating this risk demands a sustained focus on the security and resiliency of the system architecture including software, hardware, and other components. Robust software engineering practices contribute to the foundation of a resilient system so that the system "can take a hit to a critical component and recover in a known, bounded, and generally acceptable period of time". Software resiliency must be a priority and addressed early in the life cycle development to contribute a secure and dependable space system. Those who develop, implement, and operate software intensive space systems must determine the factors and systems engineering practices to address when investing in software resiliency. This dissertation offers methodical approaches for improving space system resiliency through software architecture design, system engineering, increased software security, thereby reducing the risk of latent software defects and vulnerabilities. By providing greater attention to the early life cycle phases of development, we can alter the engineering process to help detect, eliminate, and avoid vulnerabilities before space systems are delivered. To achieve this objective, this dissertation will identify knowledge, techniques, and tools that engineers and managers can utilize to help them recognize how vulnerabilities are produced and discovered so that they can learn to circumvent them in future efforts. We conducted a systematic review of existing architectural practices, standards, security and coding practices, various threats, defects, and vulnerabilities that impact space systems from hundreds of relevant publications and interviews of subject matter experts. We expanded on the system-level body of knowledge for resiliency and identified a new software architecture framework and acquisition methodology to improve the resiliency of space systems from a software perspective with an emphasis on the early phases of the systems engineering life cycle. This methodology involves seven steps: 1) Define technical resiliency requirements, 1a) Identify standards/policy for software resiliency, 2) Develop a request for proposal (RFP)/statement of work (SOW) for resilient space systems software, 3) Define software resiliency goals for space systems, 4) Establish software resiliency quality attributes, 5) Perform architectural tradeoffs and identify risks, 6) Conduct architecture assessments as part of the procurement process, and 7) Ascertain space system software architecture resiliency metrics. Data illustrates that software vulnerabilities can lead to opportunities for malicious cyber activities, which could degrade the space mission capability for the user community. Reducing the number of vulnerabilities by improving architecture and software system engineering practices can contribute to making space systems more resilient. Since cyber-attacks are enabled by shortfalls in software, robust software engineering practices and an architectural design are foundational to resiliency, which is a quality that allows the system to "take a hit to a critical component and recover in a known, bounded, and generally acceptable period of time". To achieve software resiliency for space systems, acquirers and suppliers must identify relevant factors and systems engineering practices to apply across the lifecycle, in software requirements analysis, architecture development, design, implementation, verification and validation, and maintenance phases.

  20. Large radius of curvature measurement based on the evaluation of interferogram-quality metric in non-null interferometry

    NASA Astrophysics Data System (ADS)

    Yang, Zhongming; Dou, Jiantai; Du, Jinyu; Gao, Zhishan

    2018-03-01

    Non-null interferometry could use to measure the radius of curvature (ROC), we have presented a virtual quadratic Newton rings phase-shifting moiré-fringes measurement method for large ROC measurement (Yang et al., 2016). In this paper, we propose a large ROC measurement method based on the evaluation of the interferogram-quality metric by the non-null interferometer. With the multi-configuration model of the non-null interferometric system in ZEMAX, the retrace errors and the phase introduced by the test surface are reconstructed. The interferogram-quality metric is obtained by the normalized phase-shifted testing Newton rings with the spherical surface model in the non-null interferometric system. The radius curvature of the test spherical surface can be obtained until the minimum of the interferogram-quality metric is found. Simulations and experimental results are verified the feasibility of our proposed method. For a spherical mirror with a ROC of 41,400 mm, the measurement accuracy is better than 0.13%.

  1. Biotic, water-quality, and hydrologic metrics calculated for the analysis of temporal trends in National Water Quality Assessment Program Data in the Western United States

    USGS Publications Warehouse

    Wiele, Stephen M.; Brasher, Anne M.D.; Miller, Matthew P.; May, Jason T.; Carpenter, Kurt D.

    2012-01-01

    The U.S. Geological Survey's National Water-Quality Assessment (NAWQA) Program was established by Congress in 1991 to collect long-term, nationally consistent information on the quality of the Nation's streams and groundwater. The NAWQA Program utilizes interdisciplinary and dynamic studies that link the chemical and physical conditions of streams (such as flow and habitat) with ecosystem health and the biologic condition of algae, aquatic invertebrates, and fish communities. This report presents metrics derived from NAWQA data and the U.S. Geological Survey streamgaging network for sampling sites in the Western United States, as well as associated chemical, habitat, and streamflow properties. The metrics characterize the conditions of algae, aquatic invertebrates, and fish. In addition, we have compiled climate records and basin characteristics related to the NAWQA sampling sites. The calculated metrics and compiled data can be used to analyze ecohydrologic trends over time.

  2. Essential metrics for assessing sex & gender integration in health research proposals involving human participants.

    PubMed

    Day, Suzanne; Mason, Robin; Tannenbaum, Cara; Rochon, Paula A

    2017-01-01

    Integrating sex and gender in health research is essential to produce the best possible evidence to inform health care. Comprehensive integration of sex and gender requires considering these variables from the very beginning of the research process, starting at the proposal stage. To promote excellence in sex and gender integration, we have developed a set of metrics to assess the quality of sex and gender integration in research proposals. These metrics are designed to assist both researchers in developing proposals and reviewers in making funding decisions. We developed this tool through an iterative three-stage method involving 1) review of existing sex and gender integration resources and initial metrics design, 2) expert review and feedback via anonymous online survey (Likert scale and open-ended questions), and 3) analysis of feedback data and collective revision of the metrics. We received feedback on the initial metrics draft from 20 reviewers with expertise in conducting sex- and/or gender-based health research. The majority of reviewers responded positively to questions regarding the utility, clarity and completeness of the metrics, and all reviewers provided responses to open-ended questions about suggestions for improvements. Coding and analysis of responses identified three domains for improvement: clarifying terminology, refining content, and broadening applicability. Based on this analysis we revised the metrics into the Essential Metrics for Assessing Sex and Gender Integration in Health Research Proposals Involving Human Participants, which outlines criteria for excellence within each proposal component and provides illustrative examples to support implementation. By enhancing the quality of sex and gender integration in proposals, the metrics will help to foster comprehensive, meaningful integration of sex and gender throughout each stage of the research process, resulting in better quality evidence to inform health care for all.

  3. Essential metrics for assessing sex & gender integration in health research proposals involving human participants

    PubMed Central

    Mason, Robin; Tannenbaum, Cara; Rochon, Paula A.

    2017-01-01

    Integrating sex and gender in health research is essential to produce the best possible evidence to inform health care. Comprehensive integration of sex and gender requires considering these variables from the very beginning of the research process, starting at the proposal stage. To promote excellence in sex and gender integration, we have developed a set of metrics to assess the quality of sex and gender integration in research proposals. These metrics are designed to assist both researchers in developing proposals and reviewers in making funding decisions. We developed this tool through an iterative three-stage method involving 1) review of existing sex and gender integration resources and initial metrics design, 2) expert review and feedback via anonymous online survey (Likert scale and open-ended questions), and 3) analysis of feedback data and collective revision of the metrics. We received feedback on the initial metrics draft from 20 reviewers with expertise in conducting sex- and/or gender-based health research. The majority of reviewers responded positively to questions regarding the utility, clarity and completeness of the metrics, and all reviewers provided responses to open-ended questions about suggestions for improvements. Coding and analysis of responses identified three domains for improvement: clarifying terminology, refining content, and broadening applicability. Based on this analysis we revised the metrics into the Essential Metrics for Assessing Sex and Gender Integration in Health Research Proposals Involving Human Participants, which outlines criteria for excellence within each proposal component and provides illustrative examples to support implementation. By enhancing the quality of sex and gender integration in proposals, the metrics will help to foster comprehensive, meaningful integration of sex and gender throughout each stage of the research process, resulting in better quality evidence to inform health care for all. PMID:28854192

  4. Perceptual video quality assessment in H.264 video coding standard using objective modeling.

    PubMed

    Karthikeyan, Ramasamy; Sainarayanan, Gopalakrishnan; Deepa, Subramaniam Nachimuthu

    2014-01-01

    Since usage of digital video is wide spread nowadays, quality considerations have become essential, and industry demand for video quality measurement is rising. This proposal provides a method of perceptual quality assessment in H.264 standard encoder using objective modeling. For this purpose, quality impairments are calculated and a model is developed to compute the perceptual video quality metric based on no reference method. Because of the shuttle difference between the original video and the encoded video the quality of the encoded picture gets degraded, this quality difference is introduced by the encoding process like Intra and Inter prediction. The proposed model takes into account of the artifacts introduced by these spatial and temporal activities in the hybrid block based coding methods and an objective modeling of these artifacts into subjective quality estimation is proposed. The proposed model calculates the objective quality metric using subjective impairments; blockiness, blur and jerkiness compared to the existing bitrate only calculation defined in the ITU G 1070 model. The accuracy of the proposed perceptual video quality metrics is compared against popular full reference objective methods as defined by VQEG.

  5. Metrics in method engineering

    NASA Astrophysics Data System (ADS)

    Brinkkemper, S.; Rossi, M.

    1994-12-01

    As customizable computer aided software engineering (CASE) tools, or CASE shells, have been introduced in academia and industry, there has been a growing interest into the systematic construction of methods and their support environments, i.e. method engineering. To aid the method developers and method selectors in their tasks, we propose two sets of metrics, which measure the complexity of diagrammatic specification techniques on the one hand, and of complete systems development methods on the other hand. Proposed metrics provide a relatively fast and simple way to analyze the technique (or method) properties, and when accompanied with other selection criteria, can be used for estimating the cost of learning the technique and the relative complexity of a technique compared to others. To demonstrate the applicability of the proposed metrics, we have applied them to 34 techniques and 15 methods.

  6. Multivariate Analyses of Quality Metrics for Crystal Structures in the PDB Archive.

    PubMed

    Shao, Chenghua; Yang, Huanwang; Westbrook, John D; Young, Jasmine Y; Zardecki, Christine; Burley, Stephen K

    2017-03-07

    Following deployment of an augmented validation system by the Worldwide Protein Data Bank (wwPDB) partnership, the quality of crystal structures entering the PDB has improved. Of significance are improvements in quality measures now prominently displayed in the wwPDB validation report. Comparisons of PDB depositions made before and after introduction of the new reporting system show improvements in quality measures relating to pairwise atom-atom clashes, side-chain torsion angle rotamers, and local agreement between the atomic coordinate structure model and experimental electron density data. These improvements are largely independent of resolution limit and sample molecular weight. No significant improvement in the quality of associated ligands was observed. Principal component analysis revealed that structure quality could be summarized with three measures (Rfree, real-space R factor Z score, and a combined molecular geometry quality metric), which can in turn be reduced to a single overall quality metric readily interpretable by all PDB archive users. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. A laser beam quality definition based on induced temperature rise.

    PubMed

    Miller, Harold C

    2012-12-17

    Laser beam quality metrics like M(2) can be used to describe the spot sizes and propagation behavior of a wide variety of non-ideal laser beams. However, for beams that have been diffracted by limiting apertures in the near-field, or those with unusual near-field profiles, the conventional metrics can lead to an inconsistent or incomplete description of far-field performance. This paper motivates an alternative laser beam quality definition that can be used with any beam. The approach uses a consideration of the intrinsic ability of a laser beam profile to heat a material. Comparisons are made with conventional beam quality metrics. An analysis on an asymmetric Gaussian beam is used to establish a connection with the invariant beam propagation ratio.

  8. A study of image quality for radar image processing. [synthetic aperture radar imagery

    NASA Technical Reports Server (NTRS)

    King, R. W.; Kaupp, V. H.; Waite, W. P.; Macdonald, H. C.

    1982-01-01

    Methods developed for image quality metrics are reviewed with focus on basic interpretation or recognition elements including: tone or color; shape; pattern; size; shadow; texture; site; association or context; and resolution. Seven metrics are believed to show promise as a way of characterizing the quality of an image: (1) the dynamic range of intensities in the displayed image; (2) the system signal-to-noise ratio; (3) the system spatial bandwidth or bandpass; (4) the system resolution or acutance; (5) the normalized-mean-square-error as a measure of geometric fidelity; (6) the perceptual mean square error; and (7) the radar threshold quality factor. Selective levels of degradation are being applied to simulated synthetic radar images to test the validity of these metrics.

  9. Influence of radiation dose and iterative reconstruction algorithms for measurement accuracy and reproducibility of pulmonary nodule volumetry: A phantom study.

    PubMed

    Kim, Hyungjin; Park, Chang Min; Song, Yong Sub; Lee, Sang Min; Goo, Jin Mo

    2014-05-01

    To evaluate the influence of radiation dose settings and reconstruction algorithms on the measurement accuracy and reproducibility of semi-automated pulmonary nodule volumetry. CT scans were performed on a chest phantom containing various nodules (10 and 12mm; +100, -630 and -800HU) at 120kVp with tube current-time settings of 10, 20, 50, and 100mAs. Each CT was reconstructed using filtered back projection (FBP), iDose(4) and iterative model reconstruction (IMR). Semi-automated volumetry was performed by two radiologists using commercial volumetry software for nodules at each CT dataset. Noise, contrast-to-noise ratio and signal-to-noise ratio of CT images were also obtained. The absolute percentage measurement errors and differences were then calculated for volume and mass. The influence of radiation dose and reconstruction algorithm on measurement accuracy, reproducibility and objective image quality metrics was analyzed using generalized estimating equations. Measurement accuracy and reproducibility of nodule volume and mass were not significantly associated with CT radiation dose settings or reconstruction algorithms (p>0.05). Objective image quality metrics of CT images were superior in IMR than in FBP or iDose(4) at all radiation dose settings (p<0.05). Semi-automated nodule volumetry can be applied to low- or ultralow-dose chest CT with usage of a novel iterative reconstruction algorithm without losing measurement accuracy and reproducibility. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  10. Quantitative metrics for assessment of chemical image quality and spatial resolution

    DOE PAGES

    Kertesz, Vilmos; Cahill, John F.; Van Berkel, Gary J.

    2016-02-28

    Rationale: Currently objective/quantitative descriptions of the quality and spatial resolution of mass spectrometry derived chemical images are not standardized. Development of these standardized metrics is required to objectively describe chemical imaging capabilities of existing and/or new mass spectrometry imaging technologies. Such metrics would allow unbiased judgment of intra-laboratory advancement and/or inter-laboratory comparison for these technologies if used together with standardized surfaces. Methods: We developed two image metrics, viz., chemical image contrast (ChemIC) based on signal-to-noise related statistical measures on chemical image pixels and corrected resolving power factor (cRPF) constructed from statistical analysis of mass-to-charge chronograms across features of interest inmore » an image. These metrics, quantifying chemical image quality and spatial resolution, respectively, were used to evaluate chemical images of a model photoresist patterned surface collected using a laser ablation/liquid vortex capture mass spectrometry imaging system under different instrument operational parameters. Results: The calculated ChemIC and cRPF metrics determined in an unbiased fashion the relative ranking of chemical image quality obtained with the laser ablation/liquid vortex capture mass spectrometry imaging system. These rankings were used to show that both chemical image contrast and spatial resolution deteriorated with increasing surface scan speed, increased lane spacing and decreasing size of surface features. Conclusions: ChemIC and cRPF, respectively, were developed and successfully applied for the objective description of chemical image quality and spatial resolution of chemical images collected from model surfaces using a laser ablation/liquid vortex capture mass spectrometry imaging system.« less

  11. Quantitative metrics for assessment of chemical image quality and spatial resolution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kertesz, Vilmos; Cahill, John F.; Van Berkel, Gary J.

    Rationale: Currently objective/quantitative descriptions of the quality and spatial resolution of mass spectrometry derived chemical images are not standardized. Development of these standardized metrics is required to objectively describe chemical imaging capabilities of existing and/or new mass spectrometry imaging technologies. Such metrics would allow unbiased judgment of intra-laboratory advancement and/or inter-laboratory comparison for these technologies if used together with standardized surfaces. Methods: We developed two image metrics, viz., chemical image contrast (ChemIC) based on signal-to-noise related statistical measures on chemical image pixels and corrected resolving power factor (cRPF) constructed from statistical analysis of mass-to-charge chronograms across features of interest inmore » an image. These metrics, quantifying chemical image quality and spatial resolution, respectively, were used to evaluate chemical images of a model photoresist patterned surface collected using a laser ablation/liquid vortex capture mass spectrometry imaging system under different instrument operational parameters. Results: The calculated ChemIC and cRPF metrics determined in an unbiased fashion the relative ranking of chemical image quality obtained with the laser ablation/liquid vortex capture mass spectrometry imaging system. These rankings were used to show that both chemical image contrast and spatial resolution deteriorated with increasing surface scan speed, increased lane spacing and decreasing size of surface features. Conclusions: ChemIC and cRPF, respectively, were developed and successfully applied for the objective description of chemical image quality and spatial resolution of chemical images collected from model surfaces using a laser ablation/liquid vortex capture mass spectrometry imaging system.« less

  12. A Case Study of Measuring Process Risk for Early Insights into Software Safety

    NASA Technical Reports Server (NTRS)

    Layman, Lucas; Basili, Victor; Zelkowitz, Marvin V.; Fisher, Karen L.

    2011-01-01

    In this case study, we examine software safety risk in three flight hardware systems in NASA's Constellation spaceflight program. We applied our Technical and Process Risk Measurement (TPRM) methodology to the Constellation hazard analysis process to quantify the technical and process risks involving software safety in the early design phase of these projects. We analyzed 154 hazard reports and collected metrics to measure the prevalence of software in hazards and the specificity of descriptions of software causes of hazardous conditions. We found that 49-70% of 154 hazardous conditions could be caused by software or software was involved in the prevention of the hazardous condition. We also found that 12-17% of the 2013 hazard causes involved software, and that 23-29% of all causes had a software control. The application of the TPRM methodology identified process risks in the application of the hazard analysis process itself that may lead to software safety risk.

  13. Toward Intelligent Software Defect Detection

    NASA Technical Reports Server (NTRS)

    Benson, Markland J.

    2011-01-01

    Source code level software defect detection has gone from state of the art to a software engineering best practice. Automated code analysis tools streamline many of the aspects of formal code inspections but have the drawback of being difficult to construct and either prone to false positives or severely limited in the set of defects that can be detected. Machine learning technology provides the promise of learning software defects by example, easing construction of detectors and broadening the range of defects that can be found. Pinpointing software defects with the same level of granularity as prominent source code analysis tools distinguishes this research from past efforts, which focused on analyzing software engineering metrics data with granularity limited to that of a particular function rather than a line of code.

  14. A software platform for statistical evaluation of patient respiratory patterns in radiation therapy.

    PubMed

    Dunn, Leon; Kenny, John

    2017-10-01

    The aim of this work was to design and evaluate a software tool for analysis of a patient's respiration, with the goal of optimizing the effectiveness of motion management techniques during radiotherapy imaging and treatment. A software tool which analyses patient respiratory data files (.vxp files) created by the Varian Real-Time Position Management System (RPM) was developed to analyse patient respiratory data. The software, called RespAnalysis, was created in MATLAB and provides four modules, one each for determining respiration characteristics, providing breathing coaching (biofeedback training), comparing pre and post-training characteristics and performing a fraction-by-fraction assessment. The modules analyse respiratory traces to determine signal characteristics and specifically use a Sample Entropy algorithm as the key means to quantify breathing irregularity. Simulated respiratory signals, as well as 91 patient RPM traces were analysed with RespAnalysis to test the viability of using the Sample Entropy for predicting breathing regularity. Retrospective assessment of patient data demonstrated that the Sample Entropy metric was a predictor of periodic irregularity in respiration data, however, it was found to be insensitive to amplitude variation. Additional waveform statistics assessing the distribution of signal amplitudes over time coupled with Sample Entropy method were found to be useful in assessing breathing regularity. The RespAnalysis software tool presented in this work uses the Sample Entropy method to analyse patient respiratory data recorded for motion management purposes in radiation therapy. This is applicable during treatment simulation and during subsequent treatment fractions, providing a way to quantify breathing irregularity, as well as assess the need for breathing coaching. It was demonstrated that the Sample Entropy metric was correlated to the irregularity of the patient's respiratory motion in terms of periodicity, whilst other metrics, such as percentage deviation of inhale/exhale peak positions provided insight into respiratory amplitude regularity. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  15. A Fully Automated Approach to Spike Sorting.

    PubMed

    Chung, Jason E; Magland, Jeremy F; Barnett, Alex H; Tolosa, Vanessa M; Tooker, Angela C; Lee, Kye Y; Shah, Kedar G; Felix, Sarah H; Frank, Loren M; Greengard, Leslie F

    2017-09-13

    Understanding the detailed dynamics of neuronal networks will require the simultaneous measurement of spike trains from hundreds of neurons (or more). Currently, approaches to extracting spike times and labels from raw data are time consuming, lack standardization, and involve manual intervention, making it difficult to maintain data provenance and assess the quality of scientific results. Here, we describe an automated clustering approach and associated software package that addresses these problems and provides novel cluster quality metrics. We show that our approach has accuracy comparable to or exceeding that achieved using manual or semi-manual techniques with desktop central processing unit (CPU) runtimes faster than acquisition time for up to hundreds of electrodes. Moreover, a single choice of parameters in the algorithm is effective for a variety of electrode geometries and across multiple brain regions. This algorithm has the potential to enable reproducible and automated spike sorting of larger scale recordings than is currently possible. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Nurturing reliable and robust open-source scientific software

    NASA Astrophysics Data System (ADS)

    Uieda, L.; Wessel, P.

    2017-12-01

    Scientific results are increasingly the product of software. The reproducibility and validity of published results cannot be ensured without access to the source code of the software used to produce them. Therefore, the code itself is a fundamental part of the methodology and must be published along with the results. With such a reliance on software, it is troubling that most scientists do not receive formal training in software development. Tools such as version control, continuous integration, and automated testing are routinely used in industry to ensure the correctness and robustness of software. However, many scientist do not even know of their existence (although efforts like Software Carpentry are having an impact on this issue; software-carpentry.org). Publishing the source code is only the first step in creating an open-source project. For a project to grow it must provide documentation, participation guidelines, and a welcoming environment for new contributors. Expanding the project community is often more challenging than the technical aspects of software development. Maintainers must invest time to enforce the rules of the project and to onboard new members, which can be difficult to justify in the context of the "publish or perish" mentality. This problem will continue as long as software contributions are not recognized as valid scholarship by hiring and tenure committees. Furthermore, there are still unsolved problems in providing attribution for software contributions. Many journals and metrics of academic productivity do not recognize citations to sources other than traditional publications. Thus, some authors choose to publish an article about the software and use it as a citation marker. One issue with this approach is that updating the reference to include new contributors involves writing and publishing a new article. A better approach would be to cite a permanent archive of individual versions of the source code in services such as Zenodo (zenodo.org). However, citations to these sources are not always recognized when computing citation metrics. In summary, the widespread development of reliable and robust open-source software relies on the creation of formal training programs in software development best practices and the recognition of software as a valid form of scholarship.

  17. Modernization of software quality assurance

    NASA Technical Reports Server (NTRS)

    Bhaumik, Gokul

    1988-01-01

    The customers satisfaction depends not only on functional performance, it also depends on the quality characteristics of the software products. An examination of this quality aspect of software products will provide a clear, well defined framework for quality assurance functions, which improve the life-cycle activities of software development. Software developers must be aware of the following aspects which have been expressed by many quality experts: quality cannot be added on; the level of quality built into a program is a function of the quality attributes employed during the development process; and finally, quality must be managed. These concepts have guided our development of the following definition for a Software Quality Assurance function: Software Quality Assurance is a formal, planned approach of actions designed to evaluate the degree of an identifiable set of quality attributes present in all software systems and their products. This paper is an explanation of how this definition was developed and how it is used.

  18. Software archeology: a case study in software quality assurance and design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Macdonald, John M; Lloyd, Jane A; Turner, Cameron J

    2009-01-01

    Ideally, quality is designed into software, just as quality is designed into hardware. However, when dealing with legacy systems, demonstrating that the software meets required quality standards may be difficult to achieve. As the need to demonstrate the quality of existing software was recognized at Los Alamos National Laboratory (LANL), an effort was initiated to uncover and demonstrate that legacy software met the required quality standards. This effort led to the development of a reverse engineering approach referred to as software archaeology. This paper documents the software archaeology approaches used at LANL to document legacy software systems. A case studymore » for the Robotic Integrated Packaging System (RIPS) software is included.« less

  19. Changes in biological communities of the Fountain Creek Basin, Colorado, 2003–2016, in relation to antecedent streamflow, water quality, and habitat

    USGS Publications Warehouse

    Roberts, James J.; Bruce, James F.; Zuellig, Robert E.

    2018-01-08

    The analysis described in this report is part of a longterm project monitoring the biological communities, habitat, and water quality of the Fountain Creek Basin. Biology, habitat, and water-quality data have been collected at 10 sites since 2003. These data include annual samples of aquatic invertebrate communities, fish communities, water quality, and quantitative riverine habitat. This report examines trends in biological communities from 2003 to 2016 and explores relationships between biological communities and abiotic variables (antecedent streamflow, physical habitat, and water quality). Six biological metrics (three invertebrate and three fish) and four individual fish species were used to examine trends in these data and how streamflow, habitat, and (or) water quality may explain these trends. The analysis of 79 trends shows that the majority of significant trends decreased over the trend period. Overall, 19 trends before adjustments for streamflow in the fish (12) and invertebrate (7) metrics were all decreasing except for the metric Invertebrate Species Richness at the most upstream site in Monument Creek. Seven of these trends were explained by streamflow and four trends were revealed that were originally masked by variability in antecedent streamflow. Only two sites (Jimmy Camp Creek at Fountain, CO and Fountain Creek near Pinon, CO) had no trends in the fish or invertebrate metrics. Ten of the streamflow-adjusted trends were explained by habitat, one was explained by water quality, and five were not explained by any of the variables that were tested. Overall, from 2003 to 2016, all the fish metric trends were decreasing with an average decline of 40 percent, and invertebrate metrics decreased on average by 9.5 percent. A potential peak streamflow threshold was identified above which there is severely limited production of age-0 flathead chub (Platygobio gracilis).

  20. Zone calculation as a tool for assessing performance outcome in laparoscopic suturing.

    PubMed

    Buckley, Christina E; Kavanagh, Dara O; Nugent, Emmeline; Ryan, Donncha; Traynor, Oscar J; Neary, Paul C

    2015-06-01

    Simulator performance is measured by metrics, which are valued as an objective way of assessing trainees. Certain procedures such as laparoscopic suturing, however, may not be suitable for assessment under traditionally formulated metrics. Our aim was to assess if our new metric is a valid method of assessing laparoscopic suturing. A software program was developed to order to create a new metric, which would calculate the percentage of time spent operating within pre-defined areas called "zones." Twenty-five candidates (medical students N = 10, surgical residents N = 10, and laparoscopic experts N = 5) performed the laparoscopic suturing task on the ProMIS III(®) simulator. New metrics of "in-zone" and "out-zone" scores as well as traditional metrics of time, path length, and smoothness were generated. Performance was also assessed by two blinded observers using the OSATS and FLS rating scales. This novel metric was evaluated by comparing it to both traditional metrics and subjective scores. There was a significant difference in the average in-zone and out-zone scores between all three experience groups (p < 0.05). The new zone metrics scores correlated significantly with the subjective-blinded observer scores of OSATS and FLS (p = 0.0001). The new zone metric scores also correlated significantly with the traditional metrics of path length, time, and smoothness (p < 0.05). The new metric is a valid tool for assessing laparoscopic suturing objectively. This could be incorporated into a competency-based curriculum to monitor resident progression in the simulated setting.

  1. Scatter-Reducing Sounding Filtration Using a Genetic Algorithm and Mean Monthly Standard Deviation

    NASA Technical Reports Server (NTRS)

    Mandrake, Lukas

    2013-01-01

    Retrieval algorithms like that used by the Orbiting Carbon Observatory (OCO)-2 mission generate massive quantities of data of varying quality and reliability. A computationally efficient, simple method of labeling problematic datapoints or predicting soundings that will fail is required for basic operation, given that only 6% of the retrieved data may be operationally processed. This method automatically obtains a filter designed to reduce scatter based on a small number of input features. Most machine-learning filter construction algorithms attempt to predict error in the CO2 value. By using a surrogate goal of Mean Monthly STDEV, the goal is to reduce the retrieved CO2 scatter rather than solving the harder problem of reducing CO2 error. This lends itself to improved interpretability and performance. This software reduces the scatter of retrieved CO2 values globally based on a minimum number of input features. It can be used as a prefilter to reduce the number of soundings requested, or as a post-filter to label data quality. The use of the MMS (Mean Monthly Standard deviation) provides a much cleaner, clearer filter than the standard ABS(CO2-truth) metrics previously employed by competitor methods. The software's main strength lies in a clearer (i.e., fewer features required) filter that more efficiently reduces scatter in retrieved CO2 rather than focusing on the more complex (and easily removed) bias issues.

  2. JPL Facilities and Software for Collaborative Design: 1994 - Present

    NASA Technical Reports Server (NTRS)

    DeFlorio, Paul A.

    2004-01-01

    The viewgraph presentation provides an overview of the history of the JPL Project Design Center (PDC) and, since 2000, the Center for Space Mission Architecture and Design (CSMAD). The discussion includes PDC objectives and scope; mission design metrics; distributed design; a software architecture timeline; facility design principles; optimized design for group work; CSMAD plan view, facility design, and infrastructure; and distributed collaboration tools.

  3. Using fish communities to assess streams in Romania: Initial development of an index of biotic integrity

    USGS Publications Warehouse

    Angermeier, P.L.; Davideanu, G.

    2004-01-01

    Multimetric biotic indices increasingly are used to complement physicochemical data in assessments of stream quality. We initiated development of multimetric indices, based on fish communities, to assess biotic integrity of streams in two physiographic regions of central Romania. Unlike previous efforts to develop such indices for European streams, our metrics and scoring criteria were selected largely on the basis of empirical relations in the regions of interest. We categorised 54 fish species with respect to ten natural-history attributes, then used this information to compute 32 candidate metrics of five types (taxonomic, tolerance, abundance, reproductive, and feeding) for each of 35 sites. We assessed the utility of candidate metrics for detecting anthropogenic impact based on three criteria: (a) range of values taken, (b) relation to a site-quality index (SQI), which incorporated information on hydrologic alteration, channel alteration, land-use intensity, and water chemistry, and (c) metric redundancy. We chose seven metrics from each region to include in preliminary multimetric indices (PMIs). Both PMIs included taxonomic, tolerance, and feeding metrics, but only two metrics were common to both PMIs. Although we could not validate our PMIs, their strong association with the SQI in each region suggests that such indices would be valuable tools for assessing stream quality and could provide more comprehensive assessments than the traditional approaches based solely on water chemistry.

  4. EVALUATION OF METRIC PRECISION FOR A RIPARIAN FOREST SURVEY

    EPA Science Inventory

    This paper evaluates the performance of a protocol to monitor riparian forests in western Oregon based on the quality of the data obtained from a recent field survey. Precision and accuracy are the criteria used to determine the quality of 19 field metrics. The field survey con...

  5. WATER QUALITY VULNERABILITY IN THE OZARKS USING LANDSCAPE ECOLOGY METRICS: UPPER WHITE RIVER BROWSER (V2.0)

    EPA Science Inventory

    The principal focus of this project is the mapping and interpretation of landscape scale (i.e., broad scale) ecological metrics among contributing watersheds of the Upper White River, and the development of geospatial models of water quality vulnerability for several suspected no...

  6. RT-Syn: A real-time software system generator

    NASA Technical Reports Server (NTRS)

    Setliff, Dorothy E.

    1992-01-01

    This paper presents research into providing highly reusable and maintainable components by using automatic software synthesis techniques. This proposal uses domain knowledge combined with automatic software synthesis techniques to engineer large-scale mission-critical real-time software. The hypothesis centers on a software synthesis architecture that specifically incorporates application-specific (in this case real-time) knowledge. This architecture synthesizes complex system software to meet a behavioral specification and external interaction design constraints. Some examples of these external constraints are communication protocols, precisions, timing, and space limitations. The incorporation of application-specific knowledge facilitates the generation of mathematical software metrics which are used to narrow the design space, thereby making software synthesis tractable. Success has the potential to dramatically reduce mission-critical system life-cycle costs not only by reducing development time, but more importantly facilitating maintenance, modifications, and extensions of complex mission-critical software systems, which are currently dominating life cycle costs.

  7. An Opportunistic Routing Mechanism Combined with Long-Term and Short-Term Metrics for WMN

    PubMed Central

    Piao, Xianglan; Qiu, Tie

    2014-01-01

    WMN (wireless mesh network) is a useful wireless multihop network with tremendous research value. The routing strategy decides the performance of network and the quality of transmission. A good routing algorithm will use the whole bandwidth of network and assure the quality of service of traffic. Since the routing metric ETX (expected transmission count) does not assure good quality of wireless links, to improve the routing performance, an opportunistic routing mechanism combined with long-term and short-term metrics for WMN based on OLSR (optimized link state routing) and ETX is proposed in this paper. This mechanism always chooses the highest throughput links to improve the performance of routing over WMN and then reduces the energy consumption of mesh routers. The simulations and analyses show that the opportunistic routing mechanism is better than the mechanism with the metric of ETX. PMID:25250379

  8. An opportunistic routing mechanism combined with long-term and short-term metrics for WMN.

    PubMed

    Sun, Weifeng; Wang, Haotian; Piao, Xianglan; Qiu, Tie

    2014-01-01

    WMN (wireless mesh network) is a useful wireless multihop network with tremendous research value. The routing strategy decides the performance of network and the quality of transmission. A good routing algorithm will use the whole bandwidth of network and assure the quality of service of traffic. Since the routing metric ETX (expected transmission count) does not assure good quality of wireless links, to improve the routing performance, an opportunistic routing mechanism combined with long-term and short-term metrics for WMN based on OLSR (optimized link state routing) and ETX is proposed in this paper. This mechanism always chooses the highest throughput links to improve the performance of routing over WMN and then reduces the energy consumption of mesh routers. The simulations and analyses show that the opportunistic routing mechanism is better than the mechanism with the metric of ETX.

  9. Predicting Software Suitability Using a Bayesian Belief Network

    NASA Technical Reports Server (NTRS)

    Beaver, Justin M.; Schiavone, Guy A.; Berrios, Joseph S.

    2005-01-01

    The ability to reliably predict the end quality of software under development presents a significant advantage for a development team. It provides an opportunity to address high risk components earlier in the development life cycle, when their impact is minimized. This research proposes a model that captures the evolution of the quality of a software product, and provides reliable forecasts of the end quality of the software being developed in terms of product suitability. Development team skill, software process maturity, and software problem complexity are hypothesized as driving factors of software product quality. The cause-effect relationships between these factors and the elements of software suitability are modeled using Bayesian Belief Networks, a machine learning method. This research presents a Bayesian Network for software quality, and the techniques used to quantify the factors that influence and represent software quality. The developed model is found to be effective in predicting the end product quality of small-scale software development efforts.

  10. Computer-aided diagnosis of prostate cancer using multi-parametric MRI: comparison between PUN and Tofts models

    NASA Astrophysics Data System (ADS)

    Mazzetti, S.; Giannini, V.; Russo, F.; Regge, D.

    2018-05-01

    Computer-aided diagnosis (CAD) systems are increasingly being used in clinical settings to report multi-parametric magnetic resonance imaging (mp-MRI) of the prostate. Usually, CAD systems automatically highlight cancer-suspicious regions to the radiologist, reducing reader variability and interpretation errors. Nevertheless, implementing this software requires the selection of which mp-MRI parameters can best discriminate between malignant and non-malignant regions. To exploit functional information, some parameters are derived from dynamic contrast-enhanced (DCE) acquisitions. In particular, much CAD software employs pharmacokinetic features, such as K trans and k ep, derived from the Tofts model, to estimate a likelihood map of malignancy. However, non-pharmacokinetic models can be also used to describe DCE-MRI curves, without any requirement for prior knowledge or measurement of the arterial input function, which could potentially lead to large errors in parameter estimation. In this work, we implemented an empirical function derived from the phenomenological universalities (PUN) class to fit DCE-MRI. The parameters of the PUN model are used in combination with T2-weighted and diffusion-weighted acquisitions to feed a support vector machine classifier to produce a voxel-wise malignancy likelihood map of the prostate. The results were all compared to those for a CAD system based on Tofts pharmacokinetic features to describe DCE-MRI curves, using different quality aspects of image segmentation, while also evaluating the number and size of false positive (FP) candidate regions. This study included 61 patients with 70 biopsy-proven prostate cancers (PCa). The metrics used to evaluate segmentation quality between the two CAD systems were not statistically different, although the PUN-based CAD reported a lower number of FP, with reduced size compared to the Tofts-based CAD. In conclusion, the CAD software based on PUN parameters is a feasible means with which to detect PCa, without affecting segmentation quality, and hence it could be successfully applied in clinical settings, improving the automated diagnosis process and reducing computational complexity.

  11. Performance evaluation of objective quality metrics for HDR image compression

    NASA Astrophysics Data System (ADS)

    Valenzise, Giuseppe; De Simone, Francesca; Lauga, Paul; Dufaux, Frederic

    2014-09-01

    Due to the much larger luminance and contrast characteristics of high dynamic range (HDR) images, well-known objective quality metrics, widely used for the assessment of low dynamic range (LDR) content, cannot be directly applied to HDR images in order to predict their perceptual fidelity. To overcome this limitation, advanced fidelity metrics, such as the HDR-VDP, have been proposed to accurately predict visually significant differences. However, their complex calibration may make them difficult to use in practice. A simpler approach consists in computing arithmetic or structural fidelity metrics, such as PSNR and SSIM, on perceptually encoded luminance values but the performance of quality prediction in this case has not been clearly studied. In this paper, we aim at providing a better comprehension of the limits and the potentialities of this approach, by means of a subjective study. We compare the performance of HDR-VDP to that of PSNR and SSIM computed on perceptually encoded luminance values, when considering compressed HDR images. Our results show that these simpler metrics can be effectively employed to assess image fidelity for applications such as HDR image compression.

  12. Metrication report to the Congress. 1991 activities and 1992 plans

    NASA Technical Reports Server (NTRS)

    1991-01-01

    During 1991, NASA approved a revised metric use policy and developed a NASA Metric Transition Plan. This Plan targets the end of 1995 for completion of NASA's metric initiatives. This Plan also identifies future programs that NASA anticipates will use the metric system of measurement. Field installations began metric transition studies in 1991 and will complete them in 1992. Half of NASA's Space Shuttle payloads for 1991, and almost all such payloads for 1992, have some metric-based elements. In 1992, NASA will begin assessing requirements for space-quality piece parts fabricated to U.S. metric standards, leading to development and qualification of high priority parts.

  13. Telescience Resource Kit (TReK)

    NASA Technical Reports Server (NTRS)

    Lippincott, Jeff

    2015-01-01

    Telescience Resource Kit (TReK) is one of the Huntsville Operations Support Center (HOSC) remote operations solutions. It can be used to monitor and control International Space Station (ISS) payloads from anywhere in the world. It is comprised of a suite of software applications and libraries that provide generic data system capabilities and access to HOSC services. The TReK Software has been operational since 2000. A new cross-platform version of TReK is under development. The new software is being released in phases during the 2014-2016 timeframe. The TReK Release 3.x series of software is the original TReK software that has been operational since 2000. This software runs on Windows. It contains capabilities to support traditional telemetry and commanding using CCSDS (Consultative Committee for Space Data Systems) packets. The TReK Release 4.x series of software is the new cross platform software. It runs on Windows and Linux. The new TReK software will support communication using standard IP protocols and traditional telemetry and commanding. All the software listed above is compatible and can be installed and run together on Windows. The new TReK software contains a suite of software that can be used by payload developers on the ground and onboard (TReK Toolkit). TReK Toolkit is a suite of lightweight libraries and utility applications for use onboard and on the ground. TReK Desktop is the full suite of TReK software -most useful on the ground. When TReK Desktop is released, the TReK installation program will provide the option to choose just the TReK Toolkit portion of the software or the full TReK Desktop suite. The ISS program is providing the TReK Toolkit software as a generic flight software capability offered as a standard service to payloads. TReK Software Verification was conducted during the April/May 2015 timeframe. Payload teams using the TReK software onboard can reference the TReK software verification. TReK will be demonstrated on-orbit running on an ISS provided T61p laptop. Target Timeframe: September 2015 -2016. The on-orbit demonstration will collect benchmark metrics, and will be used in the future to provide live demonstrations during ISS Payload Conferences. Benchmark metrics and demonstrations will address the protocols described in SSP 52050-0047 Ku Forward section 3.3.7. (Associated term: CCSDS File Delivery Protocol (CFDP)).

  14. A new possibility in thoracoscopic virtual reality simulation training: development and testing of a novel virtual reality simulator for video-assisted thoracoscopic surgery lobectomy.

    PubMed

    Jensen, Katrine; Bjerrum, Flemming; Hansen, Henrik Jessen; Petersen, René Horsleben; Pedersen, Jesper Holst; Konge, Lars

    2015-10-01

    The aims of this study were to develop virtual reality simulation software for video-assisted thoracic surgery (VATS) lobectomy, to explore the opinions of thoracic surgeons concerning the VATS lobectomy simulator and to test the validity of the simulator metrics. Experienced VATS surgeons worked with computer specialists to develop a VATS lobectomy software for a virtual reality simulator. Thoracic surgeons with different degrees of experience in VATS were enrolled at the 22nd meeting of the European Society of Thoracic Surgeons (ESTS) held in Copenhagen in June 2014. The surgeons were divided according to the number of performed VATS lobectomies: novices (0 VATS lobectomies), intermediates (1-49 VATS lobectomies) and experienced (>50 VATS lobectomies). The participants all performed a lobectomy of a right upper lobe on the simulator and answered a questionnaire regarding content validity. Metrics were compared between the three groups. We succeeded in developing the first version of a virtual reality VATS lobectomy simulator. A total of 103 thoracic surgeons completed the simulated lobectomy and were distributed as follows: novices n = 32, intermediates n = 45 and experienced n = 26. All groups rated the overall user realism of the VATS lobectomy scenario to a median of 5 on a scale 1-7, with 7 being the best score. The experienced surgeons found the graphics and movements realistic and rated the scenario high in terms of usefulness as a training tool for novice and intermediate experienced thoracic surgeons, but not very useful as a training tool for experienced surgeons. The metric scores were not statistically significant between groups. This is the first study to describe a commercially available virtual reality simulator for a VATS lobectomy. More than 100 thoracic surgeons found the simulator realistic, and hence it showed good content validity. However, none of the built-in simulator metrics could significantly distinguish between novice, intermediate experienced and experienced surgeons, and further development of the simulator software is necessary to develop valid metrics. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  15. Improvement of impact noise in a passenger car utilizing sound metric based on wavelet transform

    NASA Astrophysics Data System (ADS)

    Lee, Sang-Kwon; Kim, Ho-Wuk; Na, Eun-Woo

    2010-08-01

    A new sound metric for impact sound is developed based on the continuous wavelet transform (CWT), a useful tool for the analysis of non-stationary signals such as impact noise. Together with new metric, two other conventional sound metrics related to sound modulation and fluctuation are also considered. In all, three sound metrics are employed to develop impact sound quality indexes for several specific impact courses on the road. Impact sounds are evaluated subjectively by 25 jurors. The indexes are verified by comparing the correlation between the index output and results of a subjective evaluation based on a jury test. These indexes are successfully applied to an objective evaluation for improvement of the impact sound quality for cases where some parts of the suspension system of the test car are modified.

  16. SU-E-I-71: Quality Assessment of Surrogate Metrics in Multi-Atlas-Based Image Segmentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, T; Ruan, D

    Purpose: With the ever-growing data of heterogeneous quality, relevance assessment of atlases becomes increasingly critical for multi-atlas-based image segmentation. However, there is no universally recognized best relevance metric and even a standard to compare amongst candidates remains elusive. This study, for the first time, designs a quantification to assess relevance metrics’ quality, based on a novel perspective of the metric as surrogate for inferring the inaccessible oracle geometric agreement. Methods: We first develop an inference model to relate surrogate metrics in image space to the underlying oracle relevance metric in segmentation label space, with a monotonically non-decreasing function subject tomore » random perturbations. Subsequently, we investigate model parameters to reveal key contributing factors to surrogates’ ability in prognosticating the oracle relevance value, for the specific task of atlas selection. Finally, we design an effective contract-to-noise ratio (eCNR) to quantify surrogates’ quality based on insights from these analyses and empirical observations. Results: The inference model was specialized to a linear function with normally distributed perturbations, with surrogate metric exemplified by several widely-used image similarity metrics, i.e., MSD/NCC/(N)MI. Surrogates’ behaviors in selecting the most relevant atlases were assessed under varying eCNR, showing that surrogates with high eCNR dominated those with low eCNR in retaining the most relevant atlases. In an end-to-end validation, NCC/(N)MI with eCNR of 0.12 compared to MSD with eCNR of 0.10 resulted in statistically better segmentation with mean DSC of about 0.85 and the first and third quartiles of (0.83, 0.89), compared to MSD with mean DSC of 0.84 and the first and third quartiles of (0.81, 0.89). Conclusion: The designed eCNR is capable of characterizing surrogate metrics’ quality in prognosticating the oracle relevance value. It has been demonstrated to be correlated with the performance of relevant atlas selection and ultimate label fusion.« less

  17. Center to Advance Palliative Care palliative care clinical care and customer satisfaction metrics consensus recommendations.

    PubMed

    Weissman, David E; Morrison, R Sean; Meier, Diane E

    2010-02-01

    Data collection and analysis are vital for strategic planning, quality improvement, and demonstration of palliative care program impact to hospital administrators, private funders and policymakers. Since 2000, the Center to Advance Palliative Care (CAPC) has provided technical assistance to hospitals, health systems and hospices working to start, sustain, and grow nonhospice palliative care programs. CAPC convened a consensus panel in 2008 to develop recommendations for specific clinical and customer metrics that programs should track. The panel agreed on four key domains of clinical metrics and two domains of customer metrics. Clinical metrics include: daily assessment of physical/psychological/spiritual symptoms by a symptom assessment tool; establishment of patient-centered goals of care; support to patient/family caregivers; and management of transitions across care sites. For customer metrics, consensus was reached on two domains that should be tracked to assess satisfaction: patient/family satisfaction, and referring clinician satisfaction. In an effort to ensure access to reliably high-quality palliative care data throughout the nation, hospital palliative care programs are encouraged to collect and report outcomes for each of the metric domains described here.

  18. Software Quality Perceptions of Stakeholders Involved in the Software Development Process

    ERIC Educational Resources Information Center

    Padmanabhan, Priya

    2013-01-01

    Software quality is one of the primary determinants of project management success. Stakeholders involved in software development widely agree that quality is important (Barney and Wohlin 2009). However, they may differ on what constitutes software quality, and which of its attributes are more important than others. Although, software quality…

  19. A controlled experiment on the impact of software structure on maintainability

    NASA Technical Reports Server (NTRS)

    Rombach, Dieter H.

    1987-01-01

    The impact of software structure on maintainability aspects including comprehensibility, locality, modifiability, and reusability in a distributed system environment is studied in a controlled maintenance experiment involving six medium-size distributed software systems implemented in LADY (language for distributed systems) and six in an extended version of sequential PASCAL. For all maintenance aspects except reusability, the results were quantitatively given in terms of complexity metrics which could be automated. The results showed LADY to be better suited to the development of maintainable software than the extension of sequential PASCAL. The strong typing combined with high parametrization of units is suggested to improve the reusability of units in LADY.

  20. Automatic radiation dose monitoring for CT of trauma patients with different protocols: feasibility and accuracy.

    PubMed

    Higashigaito, K; Becker, A S; Sprengel, K; Simmen, H-P; Wanner, G; Alkadhi, H

    2016-09-01

    To demonstrate the feasibility and accuracy of automatic radiation dose monitoring software for computed tomography (CT) of trauma patients in a clinical setting over time, and to evaluate the potential of radiation dose reduction using iterative reconstruction (IR). In a time period of 18 months, data from 378 consecutive thoraco-abdominal CT examinations of trauma patients were extracted using automatic radiation dose monitoring software, and patients were split into three cohorts: cohort 1, 64-section CT with filtered back projection, 200 mAs tube current-time product; cohort 2, 128-section CT with IR and identical imaging protocol; cohort 3, 128-section CT with IR, 150 mAs tube current-time product. Radiation dose parameters from the software were compared with the individual patient protocols. Image noise was measured and image quality was semi-quantitatively determined. Automatic extraction of radiation dose metrics was feasible and accurate in all (100%) patients. All CT examinations were of diagnostic quality. There were no differences between cohorts 1 and 2 regarding volume CT dose index (CTDIvol; p=0.62), dose-length product (DLP), and effective dose (ED, both p=0.95), while noise was significantly lower (chest and abdomen, both -38%, p<0.017). Compared to cohort 1, CTDIvol, DLP, and ED in cohort 3 were significantly lower (all -25%, p<0.017), similar to the noise in the chest (-32%) and abdomen (-27%, both p<0.017). Compared to cohort 2, CTDIvol (-28%), DLP, and ED (both -26%) in cohort 3 was significantly lower (all, p<0.017), while noise in the chest (+9%) and abdomen (+18%) was significantly higher (all, p<0.017). Automatic radiation dose monitoring software is feasible and accurate, and can be implemented in a clinical setting for evaluating the effects of lowering radiation doses of CT protocols over time. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  1. Leveraging object-oriented development at Ames

    NASA Technical Reports Server (NTRS)

    Wenneson, Greg; Connell, John

    1994-01-01

    This paper presents lessons learned by the Software Engineering Process Group (SEPG) from results of supporting two projects at NASA Ames using an Object Oriented Rapid Prototyping (OORP) approach supported by a full featured visual development environment. Supplemental lessons learned from a large project in progress and a requirements definition are also incorporated. The paper demonstrates how productivity gains can be made by leveraging the developer with a rich development environment, correct and early requirements definition using rapid prototyping, and earlier and better effort estimation and software sizing through object-oriented methods and metrics. Although the individual elements of OO methods, RP approach and OO metrics had been used on other separate projects, the reported projects were the first integrated usage supported by a rich development environment. Overall the approach used was twice as productive (measured by hours per OO Unit) as a C++ development.

  2. The role of complexity metrics in a multi-institutional dosimetry audit of VMAT

    PubMed Central

    Agnew, Christina E; Hussein, Mohammad; Tsang, Yatman; McWilliam, Alan; Hounsell, Alan R; Clark, Catharine H

    2016-01-01

    Objective: To demonstrate the benefit of complexity metrics such as the modulation complexity score (MCS) and monitor units (MUs) in multi-institutional audits of volumetric-modulated arc therapy (VMAT) delivery. Methods: 39 VMAT treatment plans were analysed using MCS and MU. A virtual phantom planning exercise was planned and independently measured using the PTW Octavius® phantom and seven29® 2D array (PTW-Freiburg GmbH, Freiburg, Germany). MCS and MU were compared with the median gamma index pass rates (2%/2 and 3%/3 mm) and plan quality. The treatment planning systems (TPS) were grouped by VMAT modelling being specifically designed for the linear accelerator manufacturer's own treatment delivery system (Type 1) or independent of vendor for VMAT delivery (Type 2). Differences in plan complexity (MCS and MU) between TPS types were compared. Results: For Varian® linear accelerators (Varian® Medical Systems, Inc., Palo Alto, CA), MCS and MU were significantly correlated with gamma pass rates. Type 2 TPS created poorer quality, more complex plans with significantly higher MUs and MCS than Type 1 TPS. Plan quality was significantly correlated with MU for Type 2 plans. A statistically significant correlation was observed between MU and MCS for all plans (R = −0.84, p < 0.01). Conclusion: MU and MCS have a role in assessing plan complexity in audits along with plan quality metrics. Plan complexity metrics give some indication of plan deliverability but should be analysed with plan quality. Advances in knowledge: Complexity metrics were investigated for a national rotational audit involving 34 institutions and they showed value. The metrics found that more complex plans were created for planning systems which were independent of vendor for VMAT delivery. PMID:26511276

  3. Investigation of Two Models to Set and Evaluate Quality Targets for HbA1c: Biological Variation and Sigma-metrics

    PubMed Central

    Weykamp, Cas; John, Garry; Gillery, Philippe; English, Emma; Ji, Linong; Lenters-Westra, Erna; Little, Randie R.; Roglic, Gojka; Sacks, David B.; Takei, Izumi

    2016-01-01

    Background A major objective of the IFCC Task Force on implementation of HbA1c standardization is to develop a model to define quality targets for HbA1c. Methods Two generic models, the Biological Variation and Sigma-metrics model, are investigated. Variables in the models were selected for HbA1c and data of EQA/PT programs were used to evaluate the suitability of the models to set and evaluate quality targets within and between laboratories. Results In the biological variation model 48% of individual laboratories and none of the 26 instrument groups met the minimum performance criterion. In the Sigma-metrics model, with a total allowable error (TAE) set at 5 mmol/mol (0.46% NGSP) 77% of the individual laboratories and 12 of 26 instrument groups met the 2 sigma criterion. Conclusion The Biological Variation and Sigma-metrics model were demonstrated to be suitable for setting and evaluating quality targets within and between laboratories. The Sigma-metrics model is more flexible as both the TAE and the risk of failure can be adjusted to requirements related to e.g. use for diagnosis/monitoring or requirements of (inter)national authorities. With the aim of reaching international consensus on advice regarding quality targets for HbA1c, the Task Force suggests the Sigma-metrics model as the model of choice with default values of 5 mmol/mol (0.46%) for TAE, and risk levels of 2 and 4 sigma for routine laboratories and laboratories performing clinical trials, respectively. These goals should serve as a starting point for discussion with international stakeholders in the field of diabetes. PMID:25737535

  4. The role of complexity metrics in a multi-institutional dosimetry audit of VMAT.

    PubMed

    McGarry, Conor K; Agnew, Christina E; Hussein, Mohammad; Tsang, Yatman; McWilliam, Alan; Hounsell, Alan R; Clark, Catharine H

    2016-01-01

    To demonstrate the benefit of complexity metrics such as the modulation complexity score (MCS) and monitor units (MUs) in multi-institutional audits of volumetric-modulated arc therapy (VMAT) delivery. 39 VMAT treatment plans were analysed using MCS and MU. A virtual phantom planning exercise was planned and independently measured using the PTW Octavius(®) phantom and seven29(®) 2D array (PTW-Freiburg GmbH, Freiburg, Germany). MCS and MU were compared with the median gamma index pass rates (2%/2 and 3%/3 mm) and plan quality. The treatment planning systems (TPS) were grouped by VMAT modelling being specifically designed for the linear accelerator manufacturer's own treatment delivery system (Type 1) or independent of vendor for VMAT delivery (Type 2). Differences in plan complexity (MCS and MU) between TPS types were compared. For Varian(®) linear accelerators (Varian(®) Medical Systems, Inc., Palo Alto, CA), MCS and MU were significantly correlated with gamma pass rates. Type 2 TPS created poorer quality, more complex plans with significantly higher MUs and MCS than Type 1 TPS. Plan quality was significantly correlated with MU for Type 2 plans. A statistically significant correlation was observed between MU and MCS for all plans (R = -0.84, p < 0.01). MU and MCS have a role in assessing plan complexity in audits along with plan quality metrics. Plan complexity metrics give some indication of plan deliverability but should be analysed with plan quality. Complexity metrics were investigated for a national rotational audit involving 34 institutions and they showed value. The metrics found that more complex plans were created for planning systems which were independent of vendor for VMAT delivery.

  5. The MERMAID project

    NASA Technical Reports Server (NTRS)

    Cowderoy, A. J. C.; Jenkins, John O.; Poulymenakou, A

    1992-01-01

    The tendency for software development projects to be completed over schedule and over budget was documented extensively. Additionally many projects are completed within budgetary and schedule target only as a result of the customer agreeing to accept reduced functionality. In his classic book, The Mythical Man Month, Fred Brooks exposes the fallacy that effort and schedule are freely interchangeable. All current cost models are produced on the assumption that there is very limited scope for schedule compression unless there is a corresponding reduction in delivered functionality. The Metrication and Resources Modeling Aid (MERMAID) project, partially financed by the Commission of the European Communities (CEC) as Project 2046 began in Oct. 1988 and its goal were as follows: (1) improvement of understanding of the relationships between software development productivity and product and process metrics; (2) to facilitate the widespread technology transfer from the Consortium to the European Software Industry; and (3) to facilitate the widespread uptake of cost estimation techniques by the provision of prototype cost estimation tools. MERMAID developed a family of methods for cost estimation, many of which have had tools implemented in prototypes. These prototypes are best considered as toolkits or workbenches.

  6. NEW CATEGORICAL METRICS FOR AIR QUALITY MODEL EVALUATION

    EPA Science Inventory

    Traditional categorical metrics used in model evaluations are "clear-cut" measures in that the model's ability to predict an exceedance is defined by a fixed threshold concentration and the metrics are defined by observation-forecast sets that are paired both in space and time. T...

  7. StakeMeter: Value-Based Stakeholder Identification and Quantification Framework for Value-Based Software Systems

    PubMed Central

    Babar, Muhammad Imran; Ghazali, Masitah; Jawawi, Dayang N. A.; Zaheer, Kashif Bin

    2015-01-01

    Value-based requirements engineering plays a vital role in the development of value-based software (VBS). Stakeholders are the key players in the requirements engineering process, and the selection of critical stakeholders for the VBS systems is highly desirable. Based on the stakeholder requirements, the innovative or value-based idea is realized. The quality of the VBS system is associated with the concrete set of valuable requirements, and the valuable requirements can only be obtained if all the relevant valuable stakeholders participate in the requirements elicitation phase. The existing value-based approaches focus on the design of the VBS systems. However, the focus on the valuable stakeholders and requirements is inadequate. The current stakeholder identification and quantification (SIQ) approaches are neither state-of-the-art nor systematic for the VBS systems. The existing approaches are time-consuming, complex and inconsistent which makes the initiation process difficult. Moreover, the main motivation of this research is that the existing SIQ approaches do not provide the low level implementation details for SIQ initiation and stakeholder metrics for quantification. Hence, keeping in view the existing SIQ problems, this research contributes in the form of a new SIQ framework called ‘StakeMeter’. The StakeMeter framework is verified and validated through case studies. The proposed framework provides low-level implementation guidelines, attributes, metrics, quantification criteria and application procedure as compared to the other methods. The proposed framework solves the issues of stakeholder quantification or prioritization, higher time consumption, complexity, and process initiation. The framework helps in the selection of highly critical stakeholders for the VBS systems with less judgmental error. PMID:25799490

  8. DOE JGI Quality Metrics; Approaches to Scaling and Improving Metagenome Assembly (Metagenomics Informatics Challenges Workshop: 10K Genomes at a Time)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Copeland, Alex; Brown, C. Titus

    2011-10-13

    DOE JGI's Alex Copeland on "DOE JGI Quality Metrics" and Michigan State University's C. Titus Brown on "Approaches to Scaling and Improving Metagenome Assembly" at the Metagenomics Informatics Challenges Workshop held at the DOE JGI on October 12-13, 2011.

  9. 77 FR 28901 - Amended Certification Regarding Eligibility To Apply for Worker Adjustment Assistance; Lexis...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-16

    ... Elsevier, Quality & Metrics Department, Including Employees Located Throughout the United States Who Report to Miamisburg, OH; Lexis Nexis, a Subsidiary of Reed Elsevier, Quality & Metrics Department... Elsevier. The amended notice applicable to TA-W-80,205 and TA-W-80205A is hereby issued as follows: All...

  10. DOE JGI Quality Metrics; Approaches to Scaling and Improving Metagenome Assembly (Metagenomics Informatics Challenges Workshop: 10K Genomes at a Time)

    ScienceCinema

    Copeland, Alex; Brown, C. Titus

    2018-04-27

    DOE JGI's Alex Copeland on "DOE JGI Quality Metrics" and Michigan State University's C. Titus Brown on "Approaches to Scaling and Improving Metagenome Assembly" at the Metagenomics Informatics Challenges Workshop held at the DOE JGI on October 12-13, 2011.

  11. Software cost/resource modeling: Software quality tradeoff measurement

    NASA Technical Reports Server (NTRS)

    Lawler, R. W.

    1980-01-01

    A conceptual framework for treating software quality from a total system perspective is developed. Examples are given to show how system quality objectives may be allocated to hardware and software; to illustrate trades among quality factors, both hardware and software, to achieve system performance objectives; and to illustrate the impact of certain design choices on software functionality.

  12. Assessment of a novel multi-array normalization method based on spike-in control probes suitable for microRNA datasets with global decreases in expression.

    PubMed

    Sewer, Alain; Gubian, Sylvain; Kogel, Ulrike; Veljkovic, Emilija; Han, Wanjiang; Hengstermann, Arnd; Peitsch, Manuel C; Hoeng, Julia

    2014-05-17

    High-quality expression data are required to investigate the biological effects of microRNAs (miRNAs). The goal of this study was, first, to assess the quality of miRNA expression data based on microarray technologies and, second, to consolidate it by applying a novel normalization method. Indeed, because of significant differences in platform designs, miRNA raw data cannot be normalized blindly with standard methods developed for gene expression. This fundamental observation motivated the development of a novel multi-array normalization method based on controllable assumptions, which uses the spike-in control probes to adjust the measured intensities across arrays. Raw expression data were obtained with the Exiqon dual-channel miRCURY LNA™ platform in the "common reference design" and processed as "pseudo-single-channel". They were used to apply several quality metrics based on the coefficient of variation and to test the novel spike-in controls based normalization method. Most of the considerations presented here could be applied to raw data obtained with other platforms. To assess the normalization method, it was compared with 13 other available approaches from both data quality and biological outcome perspectives. The results showed that the novel multi-array normalization method reduced the data variability in the most consistent way. Further, the reliability of the obtained differential expression values was confirmed based on a quantitative reverse transcription-polymerase chain reaction experiment performed for a subset of miRNAs. The results reported here support the applicability of the novel normalization method, in particular to datasets that display global decreases in miRNA expression similarly to the cigarette smoke-exposed mouse lung dataset considered in this study. Quality metrics to assess between-array variability were used to confirm that the novel spike-in controls based normalization method provided high-quality miRNA expression data suitable for reliable downstream analysis. The multi-array miRNA raw data normalization method was implemented in an R software package called ExiMiR and deposited in the Bioconductor repository.

  13. Assessment of a novel multi-array normalization method based on spike-in control probes suitable for microRNA datasets with global decreases in expression

    PubMed Central

    2014-01-01

    Background High-quality expression data are required to investigate the biological effects of microRNAs (miRNAs). The goal of this study was, first, to assess the quality of miRNA expression data based on microarray technologies and, second, to consolidate it by applying a novel normalization method. Indeed, because of significant differences in platform designs, miRNA raw data cannot be normalized blindly with standard methods developed for gene expression. This fundamental observation motivated the development of a novel multi-array normalization method based on controllable assumptions, which uses the spike-in control probes to adjust the measured intensities across arrays. Results Raw expression data were obtained with the Exiqon dual-channel miRCURY LNA™ platform in the “common reference design” and processed as “pseudo-single-channel”. They were used to apply several quality metrics based on the coefficient of variation and to test the novel spike-in controls based normalization method. Most of the considerations presented here could be applied to raw data obtained with other platforms. To assess the normalization method, it was compared with 13 other available approaches from both data quality and biological outcome perspectives. The results showed that the novel multi-array normalization method reduced the data variability in the most consistent way. Further, the reliability of the obtained differential expression values was confirmed based on a quantitative reverse transcription–polymerase chain reaction experiment performed for a subset of miRNAs. The results reported here support the applicability of the novel normalization method, in particular to datasets that display global decreases in miRNA expression similarly to the cigarette smoke-exposed mouse lung dataset considered in this study. Conclusions Quality metrics to assess between-array variability were used to confirm that the novel spike-in controls based normalization method provided high-quality miRNA expression data suitable for reliable downstream analysis. The multi-array miRNA raw data normalization method was implemented in an R software package called ExiMiR and deposited in the Bioconductor repository. PMID:24886675

  14. Evaluation and selection of open-source EMR software packages based on integrated AHP and TOPSIS.

    PubMed

    Zaidan, A A; Zaidan, B B; Al-Haiqi, Ahmed; Kiah, M L M; Hussain, Muzammil; Abdulnabi, Mohamed

    2015-02-01

    Evaluating and selecting software packages that meet the requirements of an organization are difficult aspects of software engineering process. Selecting the wrong open-source EMR software package can be costly and may adversely affect business processes and functioning of the organization. This study aims to evaluate and select open-source EMR software packages based on multi-criteria decision-making. A hands-on study was performed and a set of open-source EMR software packages were implemented locally on separate virtual machines to examine the systems more closely. Several measures as evaluation basis were specified, and the systems were selected based a set of metric outcomes using Integrated Analytic Hierarchy Process (AHP) and TOPSIS. The experimental results showed that GNUmed and OpenEMR software can provide better basis on ranking score records than other open-source EMR software packages. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Can Technology Improve the Quality of Colonoscopy?

    PubMed

    Thirumurthi, Selvi; Ross, William A; Raju, Gottumukkala S

    2016-07-01

    In order for screening colonoscopy to be an effective tool in reducing colon cancer incidence, exams must be performed in a high-quality manner. Quality metrics have been presented by gastroenterology societies and now include higher adenoma detection rate targets than in the past. In many cases, the quality of colonoscopy can often be improved with simple low-cost interventions such as improved procedure technique, implementing split-dose bowel prep, and monitoring individuals' performances. Emerging technology has expanded our field of view and image quality during colonoscopy. We will critically review several technological advances in the context of quality metrics and discuss if technology can really improve the quality of colonoscopy.

  16. Applying the Goal-Question-Indicator-Metric (GQIM) Method to Perform Military Situational Analysis

    DTIC Science & Technology

    2016-05-11

    www.sei.cmu.edu CMU/SEI-2016-TN-003 | SOFTWARE ENGINEERING INSTITUTE | CARNEGIE MELLON UNIVERSITY Distribution Statement A: Approved for Public Release...Distribution is Unlimited Copyright 2016 Carnegie Mellon University This material is based upon work funded and supported by the Department of...Defense under Contract No. FA8721-05-C-0003 with Carnegie Mellon University for the operation of the Software Engineering Institute, a federally

  17. Enabling Software Acquisition Improvement: Government and Industry Software Development Team Acquisition Model

    DTIC Science & Technology

    2010-04-30

    estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources , gathering and maintaining...previous and current complex SW development efforts, the program offices will have a source of objective lessons learned and metrics that can be applied...the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this

  18. Filtered Push: Annotating Distributed Data for Quality Control and Fitness for Use Analysis

    NASA Astrophysics Data System (ADS)

    Morris, P. J.; Kelly, M. A.; Lowery, D. B.; Macklin, J. A.; Morris, R. A.; Tremonte, D.; Wang, Z.

    2009-12-01

    The single greatest problem with the federation of scientific data is the assessment of the quality and validity of the aggregated data in the context of particular research problems, that is, its fitness for use. There are three critical data quality issues in networks of distributed natural science collections data, as in all scientific data: identifying and correcting errors, maintaining currency, and assessing fitness for use. To this end, we have designed and implemented a prototype network in the domain of natural science collections. This prototype is built over the open source Map-Reduce platform Hadoop with a network client in the open source collections management system Specify 6. We call this network “Filtered Push” as, at its core, annotations are pushed from the network edges to relevant authoritative repositories, where humans and software filter the annotations before accepting them as changes to the authoritative data. The Filtered Push software is a domain-neutral framework for originating, distributing, and analyzing record-level annotations. Network participants can subscribe to notifications arising from ontology-based analyses of new annotations or of purpose-built queries against the network's global history of annotations. Quality and fitness for use of distributed natural science collections data can be addressed with Filtered Push software by implementing a network that allows data providers and consumers to define potential errors in data, develop metrics for those errors, specify workflows to analyze distributed data to detect potential errors, and to close the quality management cycle by providing a network architecture to pushing assertions about data quality such as corrections back to the curators of the participating data sets. Quality issues in distributed scientific data have several things in common: (1) Statements about data quality should be regarded as hypotheses about inconsistencies between perhaps several records, data sets, or practices of science. (2) Data quality problems often cannot be detected only from internal statistical correlations or logical analysis, but may need the application of defined workflows that signal illogical output. (3) Changes in scientific theory or practice over time can result in changes of what QC tests should be applied to legacy data. (4) The frequency of some classes of error in a data set may be identifiable without the ability to assert that a particular record is in error. To address these issues requires, as does science itself, framing QC hypotheses against data that may be anywhere and may arise at any time in the future. In short, QC for science data is a never ending process. It must provide for notice to an agent (human or software) that a given dataset supports a hypothesis of inconsistency with a current scientific resource or model, or with potential generalizations of the concepts in a metadata ontology. Like quality control in general, quality control of distributed data is a repeated cyclical process. In implementing a Filtered Push network for quality control, we have a model in which the cost of QC forever is not substantially greater than QC once.

  19. Sit Up Straight

    NASA Technical Reports Server (NTRS)

    1998-01-01

    BioMetric Systems has an exclusive license to the Posture Video Analysis Tool (PVAT) developed at Johnson Space Center. PVAT uses videos from Space Shuttle flights to identify limiting posture and other human factors in the workplace that could be limiting. The software also provides data that recommends appropriate postures for certain tasks and safe duration for potentially harmful positions. BioMetric Systems has further developed PVAT for use by hospitals, physical rehabilitation facilities, insurance companies, sports medicine clinics, oil companies, manufacturers, and the military.

  20. Correlation of the clinical and physical image quality in chest radiography for average adults with a computed radiography imaging system.

    PubMed

    Moore, C S; Wood, T J; Beavis, A W; Saunderson, J R

    2013-07-01

    The purpose of this study was to examine the correlation between the quality of visually graded patient (clinical) chest images and a quantitative assessment of chest phantom (physical) images acquired with a computed radiography (CR) imaging system. The results of a previously published study, in which four experienced image evaluators graded computer-simulated postero-anterior chest images using a visual grading analysis scoring (VGAS) scheme, were used for the clinical image quality measurement. Contrast-to-noise ratio (CNR) and effective dose efficiency (eDE) were used as physical image quality metrics measured in a uniform chest phantom. Although optimal values of these physical metrics for chest radiography were not derived in this work, their correlation with VGAS in images acquired without an antiscatter grid across the diagnostic range of X-ray tube voltages was determined using Pearson's correlation coefficient. Clinical and physical image quality metrics increased with decreasing tube voltage. Statistically significant correlations between VGAS and CNR (R=0.87, p<0.033) and eDE (R=0.77, p<0.008) were observed. Medical physics experts may use the physical image quality metrics described here in quality assurance programmes and optimisation studies with a degree of confidence that they reflect the clinical image quality in chest CR images acquired without an antiscatter grid. A statistically significant correlation has been found between the clinical and physical image quality in CR chest imaging. The results support the value of using CNR and eDE in the evaluation of quality in clinical thorax radiography.

  1. Software Acquisition: Evolution, Total Quality Management, and Applications to the Army Tactical Missile System

    DTIC Science & Technology

    1992-06-01

    presents the concept of software Total Quality Management (TQM) which focuses on the entire process of software acquisition, as a partial solution to...software TQM can be applied to software acquisition. Software Development, Software Acquisition, Total Quality management (TQM), Army Tactical Missile

  2. Quality metrics for sensor images

    NASA Technical Reports Server (NTRS)

    Ahumada, AL

    1993-01-01

    Methods are needed for evaluating the quality of augmented visual displays (AVID). Computational quality metrics will help summarize, interpolate, and extrapolate the results of human performance tests with displays. The FLM Vision group at NASA Ames has been developing computational models of visual processing and using them to develop computational metrics for similar problems. For example, display modeling systems use metrics for comparing proposed displays, halftoning optimizing methods use metrics to evaluate the difference between the halftone and the original, and image compression methods minimize the predicted visibility of compression artifacts. The visual discrimination models take as input two arbitrary images A and B and compute an estimate of the probability that a human observer will report that A is different from B. If A is an image that one desires to display and B is the actual displayed image, such an estimate can be regarded as an image quality metric reflecting how well B approximates A. There are additional complexities associated with the problem of evaluating the quality of radar and IR enhanced displays for AVID tasks. One important problem is the question of whether intruding obstacles are detectable in such displays. Although the discrimination model can handle detection situations by making B the original image A plus the intrusion, this detection model makes the inappropriate assumption that the observer knows where the intrusion will be. Effects of signal uncertainty need to be added to our models. A pilot needs to make decisions rapidly. The models need to predict not just the probability of a correct decision, but the probability of a correct decision by the time the decision needs to be made. That is, the models need to predict latency as well as accuracy. Luce and Green have generated models for auditory detection latencies. Similar models are needed for visual detection. Most image quality models are designed for static imagery. Watson has been developing a general spatial-temporal vision model to optimize video compression techniques. These models need to be adapted and calibrated for AVID applications.

  3. Backward Registration Based Aspect Ratio Similarity (ARS) for Image Retargeting Quality Assessment.

    PubMed

    Zhang, Yabin; Fang, Yuming; Lin, Weisi; Zhang, Xinfeng; Li, Leida

    2016-06-28

    During the past few years, there have been various kinds of content-aware image retargeting operators proposed for image resizing. However, the lack of effective objective retargeting quality assessment metrics limits the further development of image retargeting techniques. Different from traditional Image Quality Assessment (IQA) metrics, the quality degradation during image retargeting is caused by artificial retargeting modifications, and the difficulty for Image Retargeting Quality Assessment (IRQA) lies in the alternation of the image resolution and content, which makes it impossible to directly evaluate the quality degradation like traditional IQA. In this paper, we interpret the image retargeting in a unified framework of resampling grid generation and forward resampling. We show that the geometric change estimation is an efficient way to clarify the relationship between the images. We formulate the geometric change estimation as a Backward Registration problem with Markov Random Field (MRF) and provide an effective solution. The geometric change aims to provide the evidence about how the original image is resized into the target image. Under the guidance of the geometric change, we develop a novel Aspect Ratio Similarity metric (ARS) to evaluate the visual quality of retargeted images by exploiting the local block changes with a visual importance pooling strategy. Experimental results on the publicly available MIT RetargetMe and CUHK datasets demonstrate that the proposed ARS can predict more accurate visual quality of retargeted images compared with state-of-the-art IRQA metrics.

  4. EDENetworks: a user-friendly software to build and analyse networks in biogeography, ecology and population genetics.

    PubMed

    Kivelä, Mikko; Arnaud-Haond, Sophie; Saramäki, Jari

    2015-01-01

    The recent application of graph-based network theory analysis to biogeography, community ecology and population genetics has created a need for user-friendly software, which would allow a wider accessibility to and adaptation of these methods. EDENetworks aims to fill this void by providing an easy-to-use interface for the whole analysis pipeline of ecological and evolutionary networks starting from matrices of species distributions, genotypes, bacterial OTUs or populations characterized genetically. The user can choose between several different ecological distance metrics, such as Bray-Curtis or Sorensen distance, or population genetic metrics such as FST or Goldstein distances, to turn the raw data into a distance/dissimilarity matrix. This matrix is then transformed into a network by manual or automatic thresholding based on percolation theory or by building the minimum spanning tree. The networks can be visualized along with auxiliary data and analysed with various metrics such as degree, clustering coefficient, assortativity and betweenness centrality. The statistical significance of the results can be estimated either by resampling the original biological data or by null models based on permutations of the data. © 2014 John Wiley & Sons Ltd.

  5. Examining Reuse in LaSRS++-Based Projects

    NASA Technical Reports Server (NTRS)

    Madden, Michael M.

    2001-01-01

    NASA Langley Research Center (LaRC) developed the Langley Standard Real-Time Simulation in C++ (LaSRS++) to consolidate all software development for its simulation facilities under one common framework. A common framework promised a decrease in the total development effort for a new simulation by encouraging software reuse. To judge the success of LaSRS++ in this regard, reuse metrics were extracted from 11 aircraft models. Three methods that employ static analysis of the code were used to identify the reusable components. For the method that provides the best estimate, reuse levels fall between 66% and 95% indicating a high degree of reuse. Additional metrics provide insight into the extent of the foundation that LaSRS++ provides to new simulation projects. When creating variants of an aircraft, LaRC developers use object-oriented design to manage the aircraft as a reusable resource. Variants modify the aircraft for a research project or embody an alternate configuration of the aircraft. The variants inherit from the aircraft model. The variants use polymorphism to extend or redefine aircraft behaviors to meet the research requirements or to match the alternate configuration. Reuse level metrics were extracted from 10 variants. Reuse levels of aircraft by variants were 60% - 99%.

  6. Metric-driven harm: an exploration of unintended consequences of performance measurement.

    PubMed

    Rambur, Betty; Vallett, Carol; Cohen, Judith A; Tarule, Jill Mattuck

    2013-11-01

    Performance measurement is an increasingly common element of the US health care system. Typically a proxy for high quality outcomes, there has been little systematic investigation of the potential negative unintended consequences of performance metrics, including metric-driven harm. This case study details an incidence of post-surgical metric-driven harm and offers Smith's 1995 work and a patient centered, context sensitive metric model for potential adoption by nurse researchers and clinicians. Implications for further research are discussed. © 2013.

  7. A Framework of the Use of Information in Software Testing

    ERIC Educational Resources Information Center

    Kaveh, Payman

    2010-01-01

    With the increasing role that software systems play in our daily lives, software quality has become extremely important. Software quality is impacted by the efficiency of the software testing process. There are a growing number of software testing methodologies, models, and initiatives to satisfy the need to improve software quality. The main…

  8. Automation of image data processing. (Polish Title: Automatyzacja proces u przetwarzania danych obrazowych)

    NASA Astrophysics Data System (ADS)

    Preuss, R.

    2014-12-01

    This article discusses the current capabilities of automate processing of the image data on the example of using PhotoScan software by Agisoft. At present, image data obtained by various registration systems (metric and non - metric cameras) placed on airplanes, satellites, or more often on UAVs is used to create photogrammetric products. Multiple registrations of object or land area (large groups of photos are captured) are usually performed in order to eliminate obscured area as well as to raise the final accuracy of the photogrammetric product. Because of such a situation t he geometry of the resulting image blocks is far from the typical configuration of images. For fast images georeferencing automatic image matching algorithms are currently applied. They can create a model of a block in the local coordinate system or using initial exterior orientation and measured control points can provide image georeference in an external reference frame. In the case of non - metric image application, it is also possible to carry out self - calibration process at this stage. Image matching algorithm is also used in generation of dense point clouds reconstructing spatial shape of the object (area). In subsequent processing steps it is possible to obtain typical photogrammetric products such as orthomosaic, DSM or DTM and a photorealistic solid model of an object . All aforementioned processing steps are implemented in a single program in contrary to standard commercial software dividing all steps into dedicated modules. Image processing leading to final geo referenced products can be fully automated including sequential implementation of the processing steps at predetermined control parameters. The paper presents the practical results of the application fully automatic generation of othomosaic for both images obtained by a metric Vexell camera and a block of images acquired by a non - metric UAV system

  9. Selvester scoring in patients with strict LBBB using the QUARESS software.

    PubMed

    Xia, Xiaojuan; Chaudhry, Uzma; Wieslander, Björn; Borgquist, Rasmus; Wagner, Galen S; Strauss, David G; Platonov, Pyotr; Ugander, Martin; Couderc, Jean-Philippe

    2015-01-01

    Estimation of the infarct size from body-surface ECGs in post-myocardial infarction patients has become possible using the Selvester scoring method. Automation of this scoring has been proposed in order to speed-up the measurement of the score and improving the inter-observer variability in computing a score that requires strong expertise in electrocardiography. In this work, we evaluated the quality of the QuAReSS software for delivering correct Selvester scoring in a set of standard 12-lead ECGs. Standard 12-lead ECGs were recorded in 105 post-MI patients prescribed implantation of an implantable cardiodefibrillator (ICD). Amongst the 105 patients with standard clinical left bundle branch block (LBBB) patterns, 67 had a LBBB pattern meeting the strict criteria. The QuAReSS software was applied to these 67 tracings by two independent groups of cardiologists (from a clinical group and an ECG core laboratory) to measure the Selvester score semi-automatically. Using various level of agreement metrics, we compared the scores between groups and when automatically measured by the software. The average of the absolute difference in Selvester scores measured by the two independent groups was 1.4±1.5 score points, whereas the difference between automatic method and the two manual adjudications were 1.2±1.2 and 1.3±1.2 points. Eighty-two percent score agreement was observed between the two independent measurements when the difference of score was within two point ranges, while 90% and 84% score agreements were reached using the automatic method compared to the two manual adjudications. The study confirms that the QuAReSS software provides valid measurements of the Selvester score in patients with strict LBBB with minimal correction from cardiologists. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. High-quality cardiopulmonary resuscitation: current and future directions.

    PubMed

    Abella, Benjamin S

    2016-06-01

    Cardiopulmonary resuscitation (CPR) represents the cornerstone of cardiac arrest resuscitation care. Prompt delivery of high-quality CPR can dramatically improve survival outcomes; however, the definitions of optimal CPR have evolved over several decades. The present review will discuss the metrics of CPR delivery, and the evidence supporting the importance of CPR quality to improve clinical outcomes. The introduction of new technologies to quantify metrics of CPR delivery has yielded important insights into CPR quality. Investigations using CPR recording devices have allowed the assessment of specific CPR performance parameters and their relative importance regarding return of spontaneous circulation and survival to hospital discharge. Additional work has suggested new opportunities to measure physiologic markers during CPR and potentially tailor CPR delivery to patient requirements. Through recent laboratory and clinical investigations, a more evidence-based definition of high-quality CPR continues to emerge. Exciting opportunities now exist to study quantitative metrics of CPR and potentially guide resuscitation care in a goal-directed fashion. Concepts of high-quality CPR have also informed new approaches to training and quality improvement efforts for cardiac arrest care.

  11. Floristic Quality Index for woodland ground flora restoration: Utility and effectiveness in a fire-managed landscape

    Treesearch

    Calvin J. Maginel; Benjamin O. Knapp; John M. Kabrick; Rose-Marie Muzika

    2016-01-01

    Monitoring is a critical component of ecological restoration and requires the use of metrics that are meaningful and interpretable. We analyzed the effectiveness of the Floristic Quality Index (FQI), a vegetative community metric based on species richness and the level of sensitivity to anthropogenic disturbance of individual species present (Coefficient of...

  12. Methods of Measurement the Quality Metrics in a Printing System

    NASA Astrophysics Data System (ADS)

    Varepo, L. G.; Brazhnikov, A. Yu; Nagornova, I. V.; Novoselskaya, O. A.

    2018-04-01

    One of the main criteria for choosing ink as a component of printing system is scumming ability of the ink. The realization of algorithm for estimating the quality metrics in a printing system is shown. The histograms of ink rate of various printing systems are presented. A quantitative estimation of stability of offset inks emulsifiability is given.

  13. Stability Metrics for Simulation and Flight-Software Assessment and Monitoring of Adaptive Control Assist Compensators

    NASA Technical Reports Server (NTRS)

    Hodel, A. S.; Whorton, Mark; Zhu, J. Jim

    2008-01-01

    Due to a need for improved reliability and performance in aerospace systems, there is increased interest in the use of adaptive control or other nonlinear, time-varying control designs in aerospace vehicles. While such techniques are built on Lyapunov stability theory, they lack an accompanying set of metrics for the assessment of stability margins such as the classical gain and phase margins used in linear time-invariant systems. Such metrics must both be physically meaningful and permit the user to draw conclusions in a straightforward fashion. We present in this paper a roadmap to the development of metrics appropriate to nonlinear, time-varying systems. We also present two case studies in which frozen-time gain and phase margins incorrectly predict stability or instability. We then present a multi-resolution analysis approach that permits on-line real-time stability assessment of nonlinear systems.

  14. Training, Quality Assurance Factors, and Tools Investigation: a Work Report and Suggestions on Software Quality Assurance

    NASA Technical Reports Server (NTRS)

    Lee, Pen-Nan

    1991-01-01

    Previously, several research tasks have been conducted, some observations were obtained, and several possible suggestions have been contemplated involving software quality assurance engineering at NASA Johnson. These research tasks are briefly described. Also, a brief discussion is given on the role of software quality assurance in software engineering along with some observations and suggestions. A brief discussion on a training program for software quality assurance engineers is provided. A list of assurance factors as well as quality factors are also included. Finally, a process model which can be used for searching and collecting software quality assurance tools is presented.

  15. SWiFT Software Quality Assurance Plan.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berg, Jonathan Charles

    This document describes the software development practice areas and processes which contribute to the ability of SWiFT software developers to provide quality software. These processes are designed to satisfy the requirements set forth by the Sandia Software Quality Assurance Program (SSQAP). APPROVALS SWiFT Software Quality Assurance Plan (SAND2016-0765) approved by: Department Manager SWiFT Site Lead Dave Minster (6121) Date Jonathan White (6121) Date SWiFT Controls Engineer Jonathan Berg (6121) Date CHANGE HISTORY Issue Date Originator(s) Description A 2016/01/27 Jon Berg (06121) Initial release of the SWiFT Software Quality Assurance Plan

  16. Quality Controlling CMIP datasets at GFDL

    NASA Astrophysics Data System (ADS)

    Horowitz, L. W.; Radhakrishnan, A.; Balaji, V.; Adcroft, A.; Krasting, J. P.; Nikonov, S.; Mason, E. E.; Schweitzer, R.; Nadeau, D.

    2017-12-01

    As GFDL makes the switch from model development to production in light of the Climate Model Intercomparison Project (CMIP), GFDL's efforts are shifted to testing and more importantly establishing guidelines and protocols for Quality Controlling and semi-automated data publishing. Every CMIP cycle introduces key challenges and the upcoming CMIP6 is no exception. The new CMIP experimental design comprises of multiple MIPs facilitating research in different focus areas. This paradigm has implications not only for the groups that develop the models and conduct the runs, but also for the groups that monitor, analyze and quality control the datasets before data publishing, before their knowledge makes its way into reports like the IPCC (Intergovernmental Panel on Climate Change) Assessment Reports. In this talk, we discuss some of the paths taken at GFDL to quality control the CMIP-ready datasets including: Jupyter notebooks, PrePARE, LAMP (Linux, Apache, MySQL, PHP/Python/Perl): technology-driven tracker system to monitor the status of experiments qualitatively and quantitatively, provide additional metadata and analysis services along with some in-built controlled-vocabulary validations in the workflow. In addition to this, we also discuss the integration of community-based model evaluation software (ESMValTool, PCMDI Metrics Package, and ILAMB) as part of our CMIP6 workflow.

  17. Evaluation of the performance of a micromethod for measuring urinary iodine by using six sigma quality metrics.

    PubMed

    Hussain, Husniza; Khalid, Norhayati Mustafa; Selamat, Rusidah; Wan Nazaimoon, Wan Mohamud

    2013-09-01

    The urinary iodine micromethod (UIMM) is a modification of the conventional method and its performance needs evaluation. UIMM performance was evaluated using the method validation and 2008 Iodine Deficiency Disorders survey data obtained from four urinary iodine (UI) laboratories. Method acceptability tests and Sigma quality metrics were determined using total allowable errors (TEas) set by two external quality assurance (EQA) providers. UIMM obeyed various method acceptability test criteria with some discrepancies at low concentrations. Method validation data calculated against the UI Quality Program (TUIQP) TEas showed that the Sigma metrics were at 2.75, 1.80, and 3.80 for 51±15.50 µg/L, 108±32.40 µg/L, and 149±38.60 µg/L UI, respectively. External quality control (EQC) data showed that the performance of the laboratories was within Sigma metrics of 0.85-1.12, 1.57-4.36, and 1.46-4.98 at 46.91±7.05 µg/L, 135.14±13.53 µg/L, and 238.58±17.90 µg/L, respectively. No laboratory showed a calculated total error (TEcalc)

  18. Sigma metrics as a tool for evaluating the performance of internal quality control in a clinical chemistry laboratory.

    PubMed

    Kumar, B Vinodh; Mohan, Thuthi

    2018-01-01

    Six Sigma is one of the most popular quality management system tools employed for process improvement. The Six Sigma methods are usually applied when the outcome of the process can be measured. This study was done to assess the performance of individual biochemical parameters on a Sigma Scale by calculating the sigma metrics for individual parameters and to follow the Westgard guidelines for appropriate Westgard rules and levels of internal quality control (IQC) that needs to be processed to improve target analyte performance based on the sigma metrics. This is a retrospective study, and data required for the study were extracted between July 2015 and June 2016 from a Secondary Care Government Hospital, Chennai. The data obtained for the study are IQC - coefficient of variation percentage and External Quality Assurance Scheme (EQAS) - Bias% for 16 biochemical parameters. For the level 1 IQC, four analytes (alkaline phosphatase, magnesium, triglyceride, and high-density lipoprotein-cholesterol) showed an ideal performance of ≥6 sigma level, five analytes (urea, total bilirubin, albumin, cholesterol, and potassium) showed an average performance of <3 sigma level and for level 2 IQCs, same four analytes of level 1 showed a performance of ≥6 sigma level, and four analytes (urea, albumin, cholesterol, and potassium) showed an average performance of <3 sigma level. For all analytes <6 sigma level, the quality goal index (QGI) was <0.8 indicating the area requiring improvement to be imprecision except cholesterol whose QGI >1.2 indicated inaccuracy. This study shows that sigma metrics is a good quality tool to assess the analytical performance of a clinical chemistry laboratory. Thus, sigma metric analysis provides a benchmark for the laboratory to design a protocol for IQC, address poor assay performance, and assess the efficiency of existing laboratory processes.

  19. A cross-validation package driving Netica with python

    USGS Publications Warehouse

    Fienen, Michael N.; Plant, Nathaniel G.

    2014-01-01

    Bayesian networks (BNs) are powerful tools for probabilistically simulating natural systems and emulating process models. Cross validation is a technique to avoid overfitting resulting from overly complex BNs. Overfitting reduces predictive skill. Cross-validation for BNs is known but rarely implemented due partly to a lack of software tools designed to work with available BN packages. CVNetica is open-source, written in Python, and extends the Netica software package to perform cross-validation and read, rebuild, and learn BNs from data. Insights gained from cross-validation and implications on prediction versus description are illustrated with: a data-driven oceanographic application; and a model-emulation application. These examples show that overfitting occurs when BNs become more complex than allowed by supporting data and overfitting incurs computational costs as well as causing a reduction in prediction skill. CVNetica evaluates overfitting using several complexity metrics (we used level of discretization) and its impact on performance metrics (we used skill).

  20. Department of Defense Software Factbook

    DTIC Science & Technology

    2017-07-07

    parameters, these rules of thumb may not provide a lot of value to project managers estimating their software efforts. To get the information useful to them...organization determine the total cost of a particular project , but it is a useful metric to technical managers when they are required to submit an annual...outcome. It is most likely a combination of engineering, management , and funding factors. Although a project may resist planning a schedule slip, this

  1. The Warfighter Associate: Decision-Support and Metrics for Mission Command

    DTIC Science & Technology

    2013-01-01

    complex situations can be captured it makes sense to use software to provide this important adjunct to complex human cognitive problems. As a software...tasks that could distract the user from the important events occurring. An Associate System also observes the actions undertaken by a human operator...the Commander’s Critical Information Requirements. ‡It is important to note that the Warfighter Associate maintains a human -in-the-loop for decision

  2. Software reliability through fault-avoidance and fault-tolerance

    NASA Technical Reports Server (NTRS)

    Vouk, Mladen A.; Mcallister, David F.

    1993-01-01

    Strategies and tools for the testing, risk assessment and risk control of dependable software-based systems were developed. Part of this project consists of studies to enable the transfer of technology to industry, for example the risk management techniques for safety-concious systems. Theoretical investigations of Boolean and Relational Operator (BRO) testing strategy were conducted for condition-based testing. The Basic Graph Generation and Analysis tool (BGG) was extended to fully incorporate several variants of the BRO metric. Single- and multi-phase risk, coverage and time-based models are being developed to provide additional theoretical and empirical basis for estimation of the reliability and availability of large, highly dependable software. A model for software process and risk management was developed. The use of cause-effect graphing for software specification and validation was investigated. Lastly, advanced software fault-tolerance models were studied to provide alternatives and improvements in situations where simple software fault-tolerance strategies break down.

  3. Building quality into medical product software design.

    PubMed

    Mallory, S R

    1993-01-01

    The software engineering and quality assurance disciplines are a requisite to the design of safe and effective software-based medical devices. It is in the areas of software methodology and process that the most beneficial application of these disciplines to software development can be made. Software is a product of complex operations and methodologies and is not amenable to the traditional electromechanical quality assurance processes. Software quality must be built in by the developers, with the software verification and validation engineers acting as the independent instruments for ensuring compliance with performance objectives and with development and maintenance standards. The implementation of a software quality assurance program is a complex process involving management support, organizational changes, and new skill sets, but the benefits are profound. Its rewards provide safe, reliable, cost-effective, maintainable, and manageable software, which may significantly speed the regulatory review process and therefore potentially shorten the overall time to market. The use of a trial project can greatly facilitate the learning process associated with the first-time application of a software quality assurance program.

  4. Model-Based Referenceless Quality Metric of 3D Synthesized Images Using Local Image Description.

    PubMed

    Gu, Ke; Jakhetiya, Vinit; Qiao, Jun-Fei; Li, Xiaoli; Lin, Weisi; Thalmann, Daniel

    2017-07-28

    New challenges have been brought out along with the emerging of 3D-related technologies such as virtual reality (VR), augmented reality (AR), and mixed reality (MR). Free viewpoint video (FVV), due to its applications in remote surveillance, remote education, etc, based on the flexible selection of direction and viewpoint, has been perceived as the development direction of next-generation video technologies and has drawn a wide range of researchers' attention. Since FVV images are synthesized via a depth image-based rendering (DIBR) procedure in the "blind" environment (without reference images), a reliable real-time blind quality evaluation and monitoring system is urgently required. But existing assessment metrics do not render human judgments faithfully mainly because geometric distortions are generated by DIBR. To this end, this paper proposes a novel referenceless quality metric of DIBR-synthesized images using the autoregression (AR)-based local image description. It was found that, after the AR prediction, the reconstructed error between a DIBR-synthesized image and its AR-predicted image can accurately capture the geometry distortion. The visual saliency is then leveraged to modify the proposed blind quality metric to a sizable margin. Experiments validate the superiority of our no-reference quality method as compared with prevailing full-, reduced- and no-reference models.

  5. Perceptual full-reference quality assessment of stereoscopic images by considering binocular visual characteristics.

    PubMed

    Shao, Feng; Lin, Weisi; Gu, Shanbo; Jiang, Gangyi; Srikanthan, Thambipillai

    2013-05-01

    Perceptual quality assessment is a challenging issue in 3D signal processing research. It is important to study 3D signal directly instead of studying simple extension of the 2D metrics directly to the 3D case as in some previous studies. In this paper, we propose a new perceptual full-reference quality assessment metric of stereoscopic images by considering the binocular visual characteristics. The major technical contribution of this paper is that the binocular perception and combination properties are considered in quality assessment. To be more specific, we first perform left-right consistency checks and compare matching error between the corresponding pixels in binocular disparity calculation, and classify the stereoscopic images into non-corresponding, binocular fusion, and binocular suppression regions. Also, local phase and local amplitude maps are extracted from the original and distorted stereoscopic images as features in quality assessment. Then, each region is evaluated independently by considering its binocular perception property, and all evaluation results are integrated into an overall score. Besides, a binocular just noticeable difference model is used to reflect the visual sensitivity for the binocular fusion and suppression regions. Experimental results show that compared with the relevant existing metrics, the proposed metric can achieve higher consistency with subjective assessment of stereoscopic images.

  6. Outer Retinal Assessment Using Spectral-Domain Optical Coherence Tomography in Patients With Alzheimer's and Parkinson's Disease.

    PubMed

    Uchida, Atsuro; Pillai, Jagan A; Bermel, Robert; Bonner-Jackson, Aaron; Rae-Grant, Alexander; Fernandez, Hubert; Bena, James; Jones, Stephen E; Leverenz, James B; Srivastava, Sunil K; Ehlers, Justis P

    2018-06-01

    To investigate outer retinal parameters among patients with various chronic neurodegenerative disorders by using spectral-domain coherence tomography (OCT) in a prospective cross-sectional cohort study. A total of 132 participants were enrolled following a comprehensive diagnostic evaluation with neurologic, neuropsychology, and magnetic resonance imaging volumetric evaluations. Participants were 50 years or older, either diagnosed with Alzheimer's disease (AD) dementia, amnestic mild cognitive impairment (MCI), non-AD dementia, Parkinson's disease (PD), or age- and sex-matched controls. All participants underwent a macular cube scan for both eyes by using the Cirrus 4000 HD-OCT (Zeiss, Oberkochen, Germany). The OCT image with the best quality was selected for further analysis. Outer retinal parameters including ellipsoid zone mapping and outer nuclear layer metrics were evaluated with a novel software platform. One hundred twenty-four eyes of 124 participants with AD dementia (24 eyes), amnestic MCI (22 eyes), non-AD dementia (20 eyes), PD (22 eyes), and age- and sex-matched controls (36 eyes) were included in the analysis. Eight eyes were excluded either due to the presence of macular disease or poor quality of the OCT image. The mean ages of participants were 65.9 ± 8.9 years. The outer retinal thickness measures did not show any statistical significance between the groups. However, ellipsoid zone to retinal pigment epithelium volume correlated with cognitive testing scores in all study participants. There were no identifiable differences in the outer retinal metrics across neurodegenerative disease groups and controls. The relationship between the degree of cognitive impairment and ellipsoid zone to retinal pigment epithelium volume warrants further study.

  7. Miniature photometric stereo system for textile surface structure reconstruction

    NASA Astrophysics Data System (ADS)

    Gorpas, Dimitris; Kampouris, Christos; Malassiotis, Sotiris

    2013-04-01

    In this work a miniature photometric stereo system is presented, targeting the three-dimensional structural reconstruction of various fabric types. This is a supportive module to a robot system, attempting to solve the well known "laundry problem". The miniature device has been designed for mounting onto the robot gripper. It is composed of a low-cost off-the-shelf camera, operating in macro mode, and eight light emitting diodes. The synchronization between image acquisition and lighting direction is controlled by an Arduino Nano board and software triggering. The ambient light has been addressed by a cylindrical enclosure. The direction of illumination is recovered by locating the reflection or the brightest point on a mirror sphere, while a flatfielding process compensates for the non-uniform illumination. For the evaluation of this prototype, the classical photometric stereo methodology has been used. The preliminary results on a large number of textiles are very promising for the successful integration of the miniature module to the robot system. The required interaction with the robot is implemented through the estimation of the Brenner's focus measure. This metric successfully assesses the focus quality with reduced time requirements in comparison to other well accepted focus metrics. Besides the targeting application, the small size of the developed system makes it a very promising candidate for applications with space restrictions, like the quality control in industrial production lines or object recognition based on structural information and in applications where easiness in operation and light-weight are required, like those in the Biomedical field, and especially in dermatology.

  8. Toward a perceptual image quality assessment of color quantized images

    NASA Astrophysics Data System (ADS)

    Frackiewicz, Mariusz; Palus, Henryk

    2018-04-01

    Color image quantization is an important operation in the field of color image processing. In this paper, we consider new perceptual image quality metrics for assessment of quantized images. These types of metrics, e.g. DSCSI, MDSIs, MDSIm and HPSI achieve the highest correlation coefficients with MOS during tests on the six publicly available image databases. Research was limited to images distorted by two types of compression: JPG and JPG2K. Statistical analysis of correlation coefficients based on the Friedman test and post-hoc procedures showed that the differences between the four new perceptual metrics are not statistically significant.

  9. Toward determining melt pool quality metrics via coaxial monitoring in laser powder bed fusion.

    PubMed

    Fisher, Brian A; Lane, Brandon; Yeung, Ho; Beuth, Jack

    2018-01-01

    The current industry trend in metal additive manufacturing is towards greater real time process monitoring capabilities during builds to ensure high quality parts. While the hardware implementations that allow for real time monitoring of the melt pool have advanced significantly, the knowledge required to correlate the generated data to useful metrics of interest are still lacking. This research presents promising results that aim to bridge this knowledge gap by determining a novel means to correlate easily obtainable sensor data (thermal emission) to key melt pool size metrics (e.g., melt pool cross sectional area).

  10. Do Clinical Standards for Diabetes Care Address Excess Risk for Hypoglycemia in Vulnerable Patients? A Systematic Review

    PubMed Central

    Berkowitz, Seth A; Aragon, Katherine; Hines, Jonas; Seligman, Hilary; Lee, Sei; Sarkar, Urmimala

    2013-01-01

    Objective To determine whether diabetes clinical standards consider increased hypoglycemia risk in vulnerable patients. Data Sources MEDLINE, the National Guidelines Clearinghouse, the National Quality Measures Clearinghouse, and supplemental sources. Study Design Systematic review of clinical standards (guidelines, quality metrics, or pay-for-performance programs) for glycemic control in adult diabetes patients. The primary outcome was discussion of increased risk for hypoglycemia in vulnerable populations. Data Collection/Extraction Methods Manuscripts identified were abstracted by two independent reviewers using prespecified inclusion/exclusion criteria and a standardized abstraction form. Principal Findings We screened 1,166 titles, and reviewed 220 manuscripts in full text. Forty-four guidelines, 17 quality metrics, and 8 pay-for-performance programs were included. Five (11 percent) guidelines and no quality metrics or pay-for-performance programs met the primary outcome. Conclusions Clinical standards do not substantively incorporate evidence about increased risk for hypoglycemia in vulnerable populations. PMID:23445498

  11. Do clinical standards for diabetes care address excess risk for hypoglycemia in vulnerable patients? A systematic review.

    PubMed

    Berkowitz, Seth A; Aragon, Katherine; Hines, Jonas; Seligman, Hilary; Lee, Sei; Sarkar, Urmimala

    2013-08-01

    To determine whether diabetes clinical standards consider increased hypoglycemia risk in vulnerable patients. MEDLINE, the National Guidelines Clearinghouse, the National Quality Measures Clearinghouse, and supplemental sources. Systematic review of clinical standards (guidelines, quality metrics, or pay-for-performance programs) for glycemic control in adult diabetes patients. The primary outcome was discussion of increased risk for hypoglycemia in vulnerable populations. Manuscripts identified were abstracted by two independent reviewers using prespecified inclusion/exclusion criteria and a standardized abstraction form. We screened 1,166 titles, and reviewed 220 manuscripts in full text. Forty-four guidelines, 17 quality metrics, and 8 pay-for-performance programs were included. Five (11 percent) guidelines and no quality metrics or pay-for-performance programs met the primary outcome. Clinical standards do not substantively incorporate evidence about increased risk for hypoglycemia in vulnerable populations. © Health Research and Educational Trust.

  12. Quality Measures for Dialysis: Time for a Balanced Scorecard

    PubMed Central

    2016-01-01

    Recent federal legislation establishes a merit-based incentive payment system for physicians, with a scorecard for each professional. The Centers for Medicare and Medicaid Services evaluate quality of care with clinical performance measures and have used these metrics for public reporting and payment to dialysis facilities. Similar metrics may be used for the future merit-based incentive payment system. In nephrology, most clinical performance measures measure processes and intermediate outcomes of care. These metrics were developed from population studies of best practice and do not identify opportunities for individualizing care on the basis of patient characteristics and individual goals of treatment. The In-Center Hemodialysis (ICH) Consumer Assessment of Healthcare Providers and Systems (CAHPS) survey examines patients' perception of care and has entered the arena to evaluate quality of care. A balanced scorecard of quality performance should include three elements: population-based best clinical practice, patient perceptions, and individually crafted patient goals of care. PMID:26316622

  13. Correlation of the clinical and physical image quality in chest radiography for average adults with a computed radiography imaging system

    PubMed Central

    Wood, T J; Beavis, A W; Saunderson, J R

    2013-01-01

    Objective: The purpose of this study was to examine the correlation between the quality of visually graded patient (clinical) chest images and a quantitative assessment of chest phantom (physical) images acquired with a computed radiography (CR) imaging system. Methods: The results of a previously published study, in which four experienced image evaluators graded computer-simulated postero-anterior chest images using a visual grading analysis scoring (VGAS) scheme, were used for the clinical image quality measurement. Contrast-to-noise ratio (CNR) and effective dose efficiency (eDE) were used as physical image quality metrics measured in a uniform chest phantom. Although optimal values of these physical metrics for chest radiography were not derived in this work, their correlation with VGAS in images acquired without an antiscatter grid across the diagnostic range of X-ray tube voltages was determined using Pearson’s correlation coefficient. Results: Clinical and physical image quality metrics increased with decreasing tube voltage. Statistically significant correlations between VGAS and CNR (R=0.87, p<0.033) and eDE (R=0.77, p<0.008) were observed. Conclusion: Medical physics experts may use the physical image quality metrics described here in quality assurance programmes and optimisation studies with a degree of confidence that they reflect the clinical image quality in chest CR images acquired without an antiscatter grid. Advances in knowledge: A statistically significant correlation has been found between the clinical and physical image quality in CR chest imaging. The results support the value of using CNR and eDE in the evaluation of quality in clinical thorax radiography. PMID:23568362

  14. A measurement system for large, complex software programs

    NASA Technical Reports Server (NTRS)

    Rone, Kyle Y.; Olson, Kitty M.; Davis, Nathan E.

    1994-01-01

    This paper describes measurement systems required to forecast, measure, and control activities for large, complex software development and support programs. Initial software cost and quality analysis provides the foundation for meaningful management decisions as a project evolves. In modeling the cost and quality of software systems, the relationship between the functionality, quality, cost, and schedule of the product must be considered. This explicit relationship is dictated by the criticality of the software being developed. This balance between cost and quality is a viable software engineering trade-off throughout the life cycle. Therefore, the ability to accurately estimate the cost and quality of software systems is essential to providing reliable software on time and within budget. Software cost models relate the product error rate to the percent of the project labor that is required for independent verification and validation. The criticality of the software determines which cost model is used to estimate the labor required to develop the software. Software quality models yield an expected error discovery rate based on the software size, criticality, software development environment, and the level of competence of the project and developers with respect to the processes being employed.

  15. Prospective motion correction with volumetric navigators (vNavs) reduces the bias and variance in brain morphometry induced by subject motion.

    PubMed

    Tisdall, M Dylan; Reuter, Martin; Qureshi, Abid; Buckner, Randy L; Fischl, Bruce; van der Kouwe, André J W

    2016-02-15

    Recent work has demonstrated that subject motion produces systematic biases in the metrics computed by widely used morphometry software packages, even when the motion is too small to produce noticeable image artifacts. In the common situation where the control population exhibits different behaviors in the scanner when compared to the experimental population, these systematic measurement biases may produce significant confounds for between-group analyses, leading to erroneous conclusions about group differences. While previous work has shown that prospective motion correction can improve perceived image quality, here we demonstrate that, in healthy subjects performing a variety of directed motions, the use of the volumetric navigator (vNav) prospective motion correction system significantly reduces the motion-induced bias and variance in morphometry. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Parameter Search Algorithms for Microwave Radar-Based Breast Imaging: Focal Quality Metrics as Fitness Functions.

    PubMed

    O'Loughlin, Declan; Oliveira, Bárbara L; Elahi, Muhammad Adnan; Glavin, Martin; Jones, Edward; Popović, Milica; O'Halloran, Martin

    2017-12-06

    Inaccurate estimation of average dielectric properties can have a tangible impact on microwave radar-based breast images. Despite this, recent patient imaging studies have used a fixed estimate although this is known to vary from patient to patient. Parameter search algorithms are a promising technique for estimating the average dielectric properties from the reconstructed microwave images themselves without additional hardware. In this work, qualities of accurately reconstructed images are identified from point spread functions. As the qualities of accurately reconstructed microwave images are similar to the qualities of focused microscopic and photographic images, this work proposes the use of focal quality metrics for average dielectric property estimation. The robustness of the parameter search is evaluated using experimental dielectrically heterogeneous phantoms on the three-dimensional volumetric image. Based on a very broad initial estimate of the average dielectric properties, this paper shows how these metrics can be used as suitable fitness functions in parameter search algorithms to reconstruct clear and focused microwave radar images.

  17. Related Critical Psychometric Issues and Their Resolutions during Development of PE Metrics

    ERIC Educational Resources Information Center

    Fox, Connie; Zhu, Weimo; Park, Youngsik; Fisette, Jennifer L.; Graber, Kim C.; Dyson, Ben; Avery, Marybell; Franck, Marian; Placek, Judith H.; Rink, Judy; Raynes, De

    2011-01-01

    In addition to validity and reliability evidence, other psychometric qualities of the PE Metrics assessments needed to be examined. This article describes how those critical psychometric issues were addressed during the PE Metrics assessment bank construction. Specifically, issues included (a) number of items or assessments needed, (b) training…

  18. Software component quality evaluation

    NASA Technical Reports Server (NTRS)

    Clough, A. J.

    1991-01-01

    The paper describes a software inspection process that can be used to evaluate the quality of software components. Quality criteria, process application, independent testing of the process and proposed associated tool support are covered. Early results indicate that this technique is well suited for assessing software component quality in a standardized fashion. With automated machine assistance to facilitate both the evaluation and selection of software components, such a technique should promote effective reuse of software components.

  19. Image analysis software as a strategy to improve the radiographic determination of fracture healing.

    PubMed

    Duryea, Jeffrey; Evans, Christopher; Glatt, Vaida

    2018-05-28

    To develop and validate an unbiased, accurate, convenient and inexpensive means of determining when an osseous defect has healed and recovered sufficient strength to allow weight-bearing. A novel image processing software algorithm was created to analyze the radiographic images and produce a metric designed to reflect the bone strength. We used a rat femoral segmental defect model that provides a range of healing responses from complete union to non-union. Femora were examined by X-ray, micro-computed tomography (µCT) and mechanical testing. Accurate simulated radiographic images at different incident X-ray beam angles were produced from the µCT data files. The software-generated metric (SC) showed high levels of correlation with both the mechanical strength (τMech) and the polar moment of inertia (pMOI), with the mechanical testing data having the highest association. The optimization analysis yielded optimal oblique angles θB of 125° for τMech and 50° for pMOI. The Pearson's R values for the optimized model were 0.71 and 0.64 for τMech and pMOI, respectively. Further validation using true radiographs also demonstrated that the metric was accurate, and that the simulations were realistic. The preliminary findings suggest a very promising methodology to assess bone fracture healing using conventional radiography. With radiographs acquired at appropriate incident angles, it proved possible to calculate accurately the degree of healing and the mechanical strength of the bone. Further research is necessary to refine this approach and determine whether it translates to the human clinical setting.

  20. Accuracy of metric sex analysis of skeletal remains using Fordisc based on a recent skull collection.

    PubMed

    Ramsthaler, F; Kreutz, K; Verhoff, M A

    2007-11-01

    It has been generally accepted in skeletal sex determination that the use of metric methods is limited due to the population dependence of the multivariate algorithms. The aim of the study was to verify the applicability of software-based sex estimations outside the reference population group for which discriminant equations have been developed. We examined 98 skulls from recent forensic cases of known age, sex, and Caucasian ancestry from cranium collections in Frankfurt and Mainz (Germany) to determine the accuracy of sex determination using the statistical software solution Fordisc which derives its database and functions from the US American Forensic Database. In a comparison between metric analysis using Fordisc and morphological determination of sex, average accuracy for both sexes was 86 vs 94%, respectively, and males were identified more accurately than females. The ratio of the true test result rate to the false test result rate was not statistically different for the two methodological approaches at a significance level of 0.05 but was statistically different at a level of 0.10 (p=0.06). Possible explanations for this difference comprise different ancestry, age distribution, and socio-economic status compared to the Fordisc reference sample. It is likely that a discriminant function analysis on the basis of more similar European reference samples will lead to more valid and reliable sexing results. The use of Fordisc as a single method for the estimation of sex of recent skeletal remains in Europe cannot be recommended without additional morphological assessment and without a built-in software update based on modern European reference samples.

  1. National Quality Forum Colon Cancer Quality Metric Performance: How Are Hospitals Measuring Up?

    PubMed

    Mason, Meredith C; Chang, George J; Petersen, Laura A; Sada, Yvonne H; Tran Cao, Hop S; Chai, Christy; Berger, David H; Massarweh, Nader N

    2017-12-01

    To evaluate the impact of care at high-performing hospitals on the National Quality Forum (NQF) colon cancer metrics. The NQF endorses evaluating ≥12 lymph nodes (LNs), adjuvant chemotherapy (AC) for stage III patients, and AC within 4 months of diagnosis as colon cancer quality indicators. Data on hospital-level metric performance and the association with survival are unclear. Retrospective cohort study of 218,186 patients with resected stage I to III colon cancer in the National Cancer Data Base (2004-2012). High-performing hospitals (>75% achievement) were identified by the proportion of patients achieving each measure. The association between hospital performance and survival was evaluated using Cox shared frailty modeling. Only hospital LN performance improved (15.8% in 2004 vs 80.7% in 2012; trend test, P < 0.001), with 45.9% of hospitals performing well on all 3 measures concurrently in the most recent study year. Overall, 5-year survival was 75.0%, 72.3%, 72.5%, and 69.5% for those treated at hospitals with high performance on 3, 2, 1, and 0 metrics, respectively (log-rank, P < 0.001). Care at hospitals with high metric performance was associated with lower risk of death in a dose-response fashion [0 metrics, reference; 1, hazard ratio (HR) 0.96 (0.89-1.03); 2, HR 0.92 (0.87-0.98); 3, HR 0.85 (0.80-0.90); 2 vs 1, HR 0.96 (0.91-1.01); 3 vs 1, HR 0.89 (0.84-0.93); 3 vs 2, HR 0.95 (0.89-0.95)]. Performance on metrics in combination was associated with lower risk of death [LN + AC, HR 0.86 (0.78-0.95); AC + timely AC, HR 0.92 (0.87-0.98); LN + AC + timely AC, HR 0.85 (0.80-0.90)], whereas individual measures were not [LN, HR 0.95 (0.88-1.04); AC, HR 0.95 (0.87-1.05)]. Less than half of hospitals perform well on these NQF colon cancer metrics concurrently, and high performance on individual measures is not associated with improved survival. Quality improvement efforts should shift focus from individual measures to defining composite measures encompassing the overall multimodal care pathway and capturing successful transitions from one care modality to another.

  2. Uniform Data Management and Access to Near Real-Time Seismic Data (Invited)

    NASA Astrophysics Data System (ADS)

    Casey, R.; Ahern, T. K.; Benson, R. B.; Karstens, R.; Stromme, S.; Trabant, C. M.; Weertman, B. R.

    2010-12-01

    The IRIS Data Management Center has its ears to the ground, receiving relayed seismic telemetry from all parts of the globe with delay times as little as a few seconds from sensor to data center. This immediacy of always-on geophysical information has spawned a demand for ready access to persistent data streams, quality assurance metrics, and automatic production of data products based on specific triggers. For the last ten years, IRIS DMC has developed an effective near real-time data pipeline that serves the needs of seismic networks needing a central data management system as well as the scientific community that need the ability to monitor and respond to events that occurred only moments before. A number of accessible applications have been developed that provide useful data both through the web and through freely available software. Metrics and products of the raw data are cataloged and managed as a chain of events that occur in near-real time. The technical challenges faced with such a system are general to the data management community. Delayed transmission of packetized data, out of order data transmissions, verification of complete data transmission, and data flow concurrency have all been areas of focus in order to provide the best possible level of service to scientists and educators.

  3. Landscape metrics for three-dimension urban pattern recognition

    NASA Astrophysics Data System (ADS)

    Liu, M.; Hu, Y.; Zhang, W.; Li, C.

    2017-12-01

    Understanding how landscape pattern determines population or ecosystem dynamics is crucial for managing our landscapes. Urban areas are becoming increasingly dominant social-ecological systems, so it is important to understand patterns of urbanization. Most studies of urban landscape pattern examine land-use maps in two dimensions because the acquisition of 3-dimensional information is difficult. We used Brista software based on Quickbird images and aerial photos to interpret the height of buildings, thus incorporating a 3-dimensional approach. We estimated the feasibility and accuracy of this approach. A total of 164,345 buildings in the Liaoning central urban agglomeration of China, which included seven cities, were measured. Twelve landscape metrics were proposed or chosen to describe the urban landscape patterns in 2- and 3-dimensional scales. The ecological and social meaning of landscape metrics were analyzed with multiple correlation analysis. The results showed that classification accuracy compared with field surveys was 87.6%, which means this method for interpreting building height was acceptable. The metrics effectively reflected the urban architecture in relation to number of buildings, area, height, 3-D shape and diversity aspects. We were able to describe the urban characteristics of each city with these metrics. The metrics also captured ecological and social meanings. The proposed landscape metrics provided a new method for urban landscape analysis in three dimensions.

  4. Technical Note: Using k-means clustering to determine the number and position of isocenters in MLC-based multiple target intracranial radiosurgery.

    PubMed

    Yock, Adam D; Kim, Gwe-Ya

    2017-09-01

    To present the k-means clustering algorithm as a tool to address treatment planning considerations characteristic of stereotactic radiosurgery using a single isocenter for multiple targets. For 30 patients treated with stereotactic radiosurgery for multiple brain metastases, the geometric centroids and radii of each met were determined from the treatment planning system. In-house software used this as well as weighted and unweighted versions of the k-means clustering algorithm to group the targets to be treated with a single isocenter, and to position each isocenter. The algorithm results were evaluated using within-cluster sum of squares as well as a minimum target coverage metric that considered the effect of target size. Both versions of the algorithm were applied to an example patient to demonstrate the prospective determination of the appropriate number and location of isocenters. Both weighted and unweighted versions of the k-means algorithm were applied successfully to determine the number and position of isocenters. Comparing the two, both the within-cluster sum of squares metric and the minimum target coverage metric resulting from the unweighted version were less than those from the weighted version. The average magnitudes of the differences were small (-0.2 cm 2 and 0.1% for the within cluster sum of squares and minimum target coverage, respectively) but statistically significant (Wilcoxon signed-rank test, P < 0.01). The differences between the versions of the k-means clustering algorithm represented an advantage of the unweighted version for the within-cluster sum of squares metric, and an advantage of the weighted version for the minimum target coverage metric. While additional treatment planning considerations have a large influence on the final treatment plan quality, both versions of the k-means algorithm provide automatic, consistent, quantitative, and objective solutions to the tasks associated with SRS treatment planning using a single isocenter for multiple targets. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  5. Software interface verifier

    NASA Technical Reports Server (NTRS)

    Soderstrom, Tomas J.; Krall, Laura A.; Hope, Sharon A.; Zupke, Brian S.

    1994-01-01

    A Telos study of 40 recent subsystem deliveries into the DSN at JPL found software interface testing to be the single most expensive and error-prone activity, and the study team suggested creating an automated software interface test tool. The resulting Software Interface Verifier (SIV), which was funded by NASA/JPL and created by Telos, employed 92 percent software reuse to quickly create an initial version which incorporated early user feedback. SIV is now successfully used by developers for interface prototyping and unit testing, by test engineers for formal testing, and by end users for non-intrusive data flow tests in the operational environment. Metrics, including cost, are included. Lessons learned include the need for early user training. SIV is ported to many platforms and can be successfully used or tailored by other NASA groups.

  6. Pharmacy Dashboard: An Innovative Process for Pharmacy Workload and Productivity.

    PubMed

    Kinney, Ashley; Bui, Quyen; Hodding, Jane; Le, Jennifer

    2017-03-01

    Background: Innovative approaches, including LEAN systems and dashboards, to enhance pharmacy production continue to evolve in a cost and safety conscious health care environment. Furthermore, implementing and evaluating the effectiveness of these novel methods continues to be challenging for pharmacies. Objective: To describe a comprehensive, real-time pharmacy dashboard that incorporated LEAN methodologies and evaluate its utilization in an inpatient Central Intravenous Additives Services (CIVAS) pharmacy. Methods: Long Beach Memorial Hospital (462 adult beds) and Miller Children's and Women's Hospital of Long Beach (combined 324 beds) are tertiary not-for-profit, community-based hospitals that are served by one CIVAS pharmacy. Metrics to evaluate the effectiveness of CIVAS were developed and implemented on a dashboard in real-time from March 2013 to March 2014. Results: The metrics that were designed and implemented to evaluate the effectiveness of CIVAS were quality and value, financial resilience, and the department's people and culture. Using a dashboard that integrated these metrics, the accuracy of manufacturing defect-free products was ≥99.9%, indicating excellent quality and value of CIVAS. The metric for financial resilience demonstrated a cost savings of $78,000 annually within pharmacy by eliminating the outsourcing of products. People and value metrics on the dashboard focused on standard work, with an overall 94.6% compliance to the workflow. Conclusion: A unique dashboard that incorporated metrics to monitor 3 important areas was successfully implemented to improve the effectiveness of CIVAS pharmacy. These metrics helped pharmacy to monitor progress in real-time, allowing attainment of production goals and fostering continuous quality improvement through LEAN work.

  7. Pharmacy Dashboard: An Innovative Process for Pharmacy Workload and Productivity

    PubMed Central

    Bui, Quyen; Hodding, Jane; Le, Jennifer

    2017-01-01

    Background: Innovative approaches, including LEAN systems and dashboards, to enhance pharmacy production continue to evolve in a cost and safety conscious health care environment. Furthermore, implementing and evaluating the effectiveness of these novel methods continues to be challenging for pharmacies. Objective: To describe a comprehensive, real-time pharmacy dashboard that incorporated LEAN methodologies and evaluate its utilization in an inpatient Central Intravenous Additives Services (CIVAS) pharmacy. Methods: Long Beach Memorial Hospital (462 adult beds) and Miller Children's and Women's Hospital of Long Beach (combined 324 beds) are tertiary not-for-profit, community-based hospitals that are served by one CIVAS pharmacy. Metrics to evaluate the effectiveness of CIVAS were developed and implemented on a dashboard in real-time from March 2013 to March 2014. Results: The metrics that were designed and implemented to evaluate the effectiveness of CIVAS were quality and value, financial resilience, and the department's people and culture. Using a dashboard that integrated these metrics, the accuracy of manufacturing defect-free products was ≥99.9%, indicating excellent quality and value of CIVAS. The metric for financial resilience demonstrated a cost savings of $78,000 annually within pharmacy by eliminating the outsourcing of products. People and value metrics on the dashboard focused on standard work, with an overall 94.6% compliance to the workflow. Conclusion: A unique dashboard that incorporated metrics to monitor 3 important areas was successfully implemented to improve the effectiveness of CIVAS pharmacy. These metrics helped pharmacy to monitor progress in real-time, allowing attainment of production goals and fostering continuous quality improvement through LEAN work. PMID:28439134

  8. Advanced Life Support Research and Technology Development Metric: Fiscal Year 2003

    NASA Technical Reports Server (NTRS)

    Hanford, A. J.

    2004-01-01

    This document provides the official calculation of the Advanced Life Support (ALS) Research and Technology Development Metric (the Metric) for Fiscal Year 2003. As such, the values herein are primarily based on Systems Integration, Modeling, and Analysis (SIMA) Element approved software tools or reviewed and approved reference documents. The Metric is one of several measures employed by the National Aeronautics and Space Administration (NASA) to assess the Agency s progress as mandated by the United States Congress and the Office of Management and Budget. Because any measure must have a reference point, whether explicitly defined or implied, the Metric is a comparison between a selected ALS Project life support system and an equivalently detailed life support system using technology from the Environmental Control and Life Support System (ECLSS) for the International Space Station (ISS). More specifically, the Metric is the ratio defined by the equivalent system mass (ESM) of a life support system for a specific mission using the ISS ECLSS technologies divided by the ESM for an equivalent life support system using the best ALS technologies. As defined, the Metric should increase in value as the ALS technologies become lighter, less power intensive, and require less volume. For Fiscal Year 2003, the Advanced Life Support Research and Technology Development Metric value is 1.47 for an Orbiting Research Facility and 1.36 for an Independent Exploration Mission.

  9. Weighting and Bayes Nets for Rollup of Surveillance Metrics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Henson, Kriste; Sentz, Kari; Hamada, Michael

    2012-04-30

    The LANL IKE team proposes that the surveillance metrics for several data stream that are used to detect the same failure mode be weighted. Similarly, the failure mode metrics are weighted to obtain a subsystem metric. E.g., if there n data streams (nodes 1-n), the failure mode (node 0) metric is obtained as M{sub 0} = w{sub 1}M{sub 1} + {hor_ellipsis} + w{sub n}M{sub n}, where {Sigma}{sub i=1}{sup n} w{sub i} = 1. This proposal has been implemented with Bayes Nets using the Netica/IKE software by specifying an appropriate conditional probability table (CPT). This CPT is calculated using the samemore » form as (1), where the data stream metrics for the true (T) and false (F) states are replaced by 1 and 0, respectively. Then using this CPT, the failure mode metric calculated by Netica/IKE equals (1). This result has two nice features. First, the rollup Bayes nets is doing can be easily explained. Second, because Bayes Nets can implement this rollup using Netica/IKE, then data marshalling (allocating next year's budget) can be studied. A proof that the claim 'failure mode metric calculated by Netica/IKE equals (1)' for n = 2 and n = 3 follows as well as the sketch of a proof by induction for general n.« less

  10. Developments in Seismic Data Quality Assessment Using MUSTANG at the IRIS DMC

    NASA Astrophysics Data System (ADS)

    Sharer, G.; Keyson, L.; Templeton, M. E.; Weertman, B.; Smith, K.; Sweet, J. R.; Tape, C.; Casey, R. E.; Ahern, T.

    2017-12-01

    MUSTANG is the automated data quality metrics system at the IRIS Data Management Center (DMC), designed to help characterize data and metadata "goodness" across the IRIS data archive, which holds 450 TB of seismic and related earth science data spanning the past 40 years. It calculates 46 metrics ranging from sample statistics and miniSEED state-of-health flag counts to Power Spectral Densities (PSDs) and Probability Density Functions (PDFs). These quality measurements are easily and efficiently accessible to users through the use of web services, which allows users to make requests not only by station and time period but also to filter the results according to metric values that match a user's data requirements. Results are returned in a variety of formats, including XML, JSON, CSV, and text. In the case of PSDs and PDFs, results can also be retrieved as plot images. In addition, there are several user-friendly client tools available for exploring and visualizing MUSTANG metrics: LASSO, MUSTANG Databrowser, and MUSTANGular. Over the past year we have made significant improvements to MUSTANG. We have nearly complete coverage over our archive for broadband channels with sample rates of 20-200 sps. With this milestone achieved, we are now expanding to include higher sample rate, short-period, and strong-motion channels. Data availability metrics will soon be calculated when a request is made which guarantees that the information reflects the current state of the archive and also allows for more flexibility in content. For example, MUSTANG will be able to return a count of gaps for any arbitrary time period instead of being limited to 24 hour spans. We are also promoting the use of data quality metrics beyond the IRIS archive through our recent release of ISPAQ, a Python command-line application that calculates MUSTANG-style metrics for users' local miniSEED files or for any miniSEED data accessible through FDSN-compliant web services. Finally, we will explore how researchers are using MUSTANG in real-world situations to select data, improve station data quality, anticipate station outages and servicing, and characterize site noise and environmental conditions.

  11. Software Quality Evaluation Models Applicable in Health Information and Communications Technologies. A Review of the Literature.

    PubMed

    Villamor Ordozgoiti, Alberto; Delgado Hito, Pilar; Guix Comellas, Eva María; Fernandez Sanchez, Carlos Manuel; Garcia Hernandez, Milagros; Lluch Canut, Teresa

    2016-01-01

    Information and Communications Technologies in healthcare has increased the need to consider quality criteria through standardised processes. The aim of this study was to analyse the software quality evaluation models applicable to healthcare from the perspective of ICT-purchasers. Through a systematic literature review with the keywords software, product, quality, evaluation and health, we selected and analysed 20 original research papers published from 2005-2016 in health science and technology databases. The results showed four main topics: non-ISO models, software quality evaluation models based on ISO/IEC standards, studies analysing software quality evaluation models, and studies analysing ISO standards for software quality evaluation. The models provide cost-efficiency criteria for specific software, and improve use outcomes. The ISO/IEC25000 standard is shown as the most suitable for evaluating the quality of ICTs for healthcare use from the perspective of institutional acquisition.

  12. Reprocessing Close Range Terrestrial and Uav Photogrammetric Projects with the Dbat Toolbox for Independent Verification and Quality Control

    NASA Astrophysics Data System (ADS)

    Murtiyoso, A.; Grussenmeyer, P.; Börlin, N.

    2017-11-01

    Photogrammetry has recently seen a rapid increase in many applications, thanks to developments in computing power and algorithms. Furthermore with the democratisation of UAVs (Unmanned Aerial Vehicles), close range photogrammetry has seen more and more use due to the easier capability to acquire aerial close range images. In terms of photogrammetric processing, many commercial software solutions exist in the market that offer results from user-friendly environments. However, in most commercial solutions, a black-box approach to photogrammetric calculations is often used. This is understandable in light of the proprietary nature of the algorithms, but it may pose a problem if the results need to be validated in an independent manner. In this paper, the Damped Bundle Adjustment Toolbox (DBAT) developed for Matlab was used to reprocess some photogrammetric projects that were processed using the commercial software Agisoft Photoscan. Several scenarios were experimented on in order to see the performance of DBAT in reprocessing terrestrial and UAV close range photogrammetric projects in several configurations of self-calibration setting. Results show that DBAT managed to reprocess PS projects and generate metrics which can be useful for project verification.

  13. Appendix.

    ERIC Educational Resources Information Center

    NatureScope, 1988

    1988-01-01

    Provides a glossary and bibliography which includes a listing of the following: general reference books, field guides, children's books, films, filmstrips, slides, videos, coloring books, games, posters, software, activity sources, where to get more information, Ranger Rick Ocean Index, and a metric conversion chart. (RT)

  14. NASA Software Engineering Benchmarking Study

    NASA Technical Reports Server (NTRS)

    Rarick, Heather L.; Godfrey, Sara H.; Kelly, John C.; Crumbley, Robert T.; Wifl, Joel M.

    2013-01-01

    To identify best practices for the improvement of software engineering on projects, NASA's Offices of Chief Engineer (OCE) and Safety and Mission Assurance (OSMA) formed a team led by Heather Rarick and Sally Godfrey to conduct this benchmarking study. The primary goals of the study are to identify best practices that: Improve the management and technical development of software intensive systems; Have a track record of successful deployment by aerospace industries, universities [including research and development (R&D) laboratories], and defense services, as well as NASA's own component Centers; and Identify candidate solutions for NASA's software issues. Beginning in the late fall of 2010, focus topics were chosen and interview questions were developed, based on the NASA top software challenges. Between February 2011 and November 2011, the Benchmark Team interviewed a total of 18 organizations, consisting of five NASA Centers, five industry organizations, four defense services organizations, and four university or university R and D laboratory organizations. A software assurance representative also participated in each of the interviews to focus on assurance and software safety best practices. Interviewees provided a wealth of information on each topic area that included: software policy, software acquisition, software assurance, testing, training, maintaining rigor in small projects, metrics, and use of the Capability Maturity Model Integration (CMMI) framework, as well as a number of special topics that came up in the discussions. NASA's software engineering practices compared favorably with the external organizations in most benchmark areas, but in every topic, there were ways in which NASA could improve its practices. Compared to defense services organizations and some of the industry organizations, one of NASA's notable weaknesses involved communication with contractors regarding its policies and requirements for acquired software. One of NASA's strengths was its software assurance practices, which seemed to rate well in comparison to the other organizational groups and also seemed to include a larger scope of activities. An unexpected benefit of the software benchmarking study was the identification of many opportunities for collaboration in areas including metrics, training, sharing of CMMI experiences and resources such as instructors and CMMI Lead Appraisers, and even sharing of assets such as documented processes. A further unexpected benefit of the study was the feedback on NASA practices that was received from some of the organizations interviewed. From that feedback, other potential areas where NASA could improve were highlighted, such as accuracy of software cost estimation and budgetary practices. The detailed report contains discussion of the practices noted in each of the topic areas, as well as a summary of observations and recommendations from each of the topic areas. The resulting 24 recommendations from the topic areas were then consolidated to eliminate duplication and culled into a set of 14 suggested actionable recommendations. This final set of actionable recommendations, listed below, are items that can be implemented to improve NASA's software engineering practices and to help address many of the items that were listed in the NASA top software engineering issues. 1. Develop and implement standard contract language for software procurements. 2. Advance accurate and trusted software cost estimates for both procured and in-house software and improve the capture of actual cost data to facilitate further improvements. 3. Establish a consistent set of objectives and expectations, specifically types of metrics at the Agency level, so key trends and models can be identified and used to continuously improve software processes and each software development effort. 4. Maintain the CMMI Maturity Level requirement for critical NASA projects and use CMMI to measure organizations developing software for NASA. 5.onsolidate, collect and, if needed, develop common processes principles and other assets across the Agency in order to provide more consistency in software development and acquisition practices and to reduce the overall cost of maintaining or increasing current NASA CMMI maturity levels. 6. Provide additional support for small projects that includes: (a) guidance for appropriate tailoring of requirements for small projects, (b) availability of suitable tools, including support tool set-up and training, and (c) training for small project personnel, assurance personnel and technical authorities on the acceptable options for tailoring requirements and performing assurance on small projects. 7. Develop software training classes for the more experienced software engineers using on-line training, videos, or small separate modules of training that can be accommodated as needed throughout a project. 8. Create guidelines to structure non-classroom training opportunities such as mentoring, peer reviews, lessons learned sessions, and on-the-job training. 9. Develop a set of predictive software defect data and a process for assessing software testing metric data against it. 10. Assess Agency-wide licenses for commonly used software tools. 11. Fill the knowledge gap in common software engineering practices for new hires and co-ops.12. Work through the Science, Technology, Engineering and Mathematics (STEM) program with universities in strengthening education in the use of common software engineering practices and standards. 13. Follow up this benchmark study with a deeper look into what both internal and external organizations perceive as the scope of software assurance, the value they expect to obtain from it, and the shortcomings they experience in the current practice. 14. Continue interactions with external software engineering environment through collaborations, knowledge sharing, and benchmarking.

  15. TREHS (Temporary Rivers Ecological and Hydrological Status): new software for investigating the degree of hydrologic alteration of temporary streams.

    NASA Astrophysics Data System (ADS)

    Gallart, Francesc; Llorens, Pilar; Cid, Núria; latron, Jérôme; Bonada, Núria; Prat, Narcís

    2017-04-01

    The evaluation of the hydrological alteration of a stream due to human activities is a first step to assess its overall quality and to design management strategies for its potential restoration. This task is currently made comparing impacted against unimpacted hydrographs, with the help of software tools, such as the IHA (Indicators of Hydrologic Alteration). Then, the environmental evaluation of the hydrological alteration is to be made in terms of its expectable menace for the original biological communities and/or its help for the spread of invasive species. However, when the regime of the target stream is not perennial, there are four main difficulties for implementing methods for assessing hydrological alteration: i) the main hydrological features relevant for biological communities in a temporary stream are not quantitative (discharges) but qualitative (temporal patterns of states such as flowing water, stagnant pools or lack of surface water), ii) stream flow records do not inform on the temporal occurrence of stagnant pools, which act as refugees for many species during the cessation of flow, iii) as most of the temporary streams are ungauged, the evaluation of their regime must be determined by using alternative methods such as remote sensing or citizen science, and iv) the biological quality assessment of the ecological status of a temporary stream must be conducted following a sampling schedule adapted to the flow regime and using adequate reference conditions. In order to overcome these challenges using an operational approach, the TREHS freely available software tool has been developed within the EU LIFE TRIVERS project (LIFE13 ENV/ES/000341). This software allows for the input of information coming from flow simulations obtained using any rainfall-runoff model (to set an unimpacted reference stream regime) and compares them with the information obtained from flow gauging records, interviews made to local citizens, instantaneous observations made by individuals, and by interpretation of aerial photographs. Up to six metrics defining the permanence of water flow, the presence of stagnant pools and their temporal patterns of occurrence are used to determine the natural and observed river regime, and to assess the degree of hydrological alteration. Here, given the lack of agreed standards to evaluate the ecological relevance of the observed alterations, the thresholds that define quality class boundaries are provisional and may be updated using expert knowledge. Finally, the software characterizes the differences between the natural and actual regimes, performs a diagnosis of the hydrological status (degree of hydrologic alteration) along with an assessment of the significance and robustness of the diagnosis, and recommends the best period for biological quality samplings.

  16. Strategic Agility: Using the Expeditionary Aerospace Force as a Framework for Assuring Strategic Relevancy in the USAF

    DTIC Science & Technology

    2014-06-01

    increases quality of life , which, in turn, leads to better retention metrics; better retention metrics translate into higher experience levels...the quality of life for Airmen, particularly two-parent military families assigned to different AEFs.46 Cognizant of an already high operations...a desire to achieve the highest quality of life for Airmen. Ryan settled on a 1:4 AEF dwell ratio to ensure Airmen were not away from home- station

  17. Model-driven approach to data collection and reporting for quality improvement

    PubMed Central

    Curcin, Vasa; Woodcock, Thomas; Poots, Alan J.; Majeed, Azeem; Bell, Derek

    2014-01-01

    Continuous data collection and analysis have been shown essential to achieving improvement in healthcare. However, the data required for local improvement initiatives are often not readily available from hospital Electronic Health Record (EHR) systems or not routinely collected. Furthermore, improvement teams are often restricted in time and funding thus requiring inexpensive and rapid tools to support their work. Hence, the informatics challenge in healthcare local improvement initiatives consists of providing a mechanism for rapid modelling of the local domain by non-informatics experts, including performance metric definitions, and grounded in established improvement techniques. We investigate the feasibility of a model-driven software approach to address this challenge, whereby an improvement model designed by a team is used to automatically generate required electronic data collection instruments and reporting tools. To that goal, we have designed a generic Improvement Data Model (IDM) to capture the data items and quality measures relevant to the project, and constructed Web Improvement Support in Healthcare (WISH), a prototype tool that takes user-generated IDM models and creates a data schema, data collection web interfaces, and a set of live reports, based on Statistical Process Control (SPC) for use by improvement teams. The software has been successfully used in over 50 improvement projects, with more than 700 users. We present in detail the experiences of one of those initiatives, Chronic Obstructive Pulmonary Disease project in Northwest London hospitals. The specific challenges of improvement in healthcare are analysed and the benefits and limitations of the approach are discussed. PMID:24874182

  18. Culture shock: Improving software quality

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    de Jong, K.; Trauth, S.L.

    1988-01-01

    The concept of software quality can represent a significant shock to an individual who has been developing software for many years and who believes he or she has been doing a high quality job. The very idea that software includes lines of code and associated documentation is foreign and difficult to grasp, at best. Implementation of a software quality program hinges on the concept that software is a product whose quality needs improving. When this idea is introduced into a technical community that is largely ''self-taught'' and has been producing ''good'' software for some time, a fundamental understanding of themore » concepts associated with software is often weak. Software developers can react as if to say, ''What are you talking about. What do you mean I'm not doing a good job. I haven't gotten any complaints about my code yetexclamation'' Coupling such surprise and resentment with the shock that software really is a product and software quality concepts do exist, can fuel the volatility of these emotions. In this paper, we demonstrate that the concept of software quality can indeed pose a culture shock to developers. We also show that a ''typical'' quality assurance approach, that of imposing a standard and providing inspectors and auditors to assure its adherence, contributes to this shock and detracts from the very goal the approach should achieve. We offer an alternative, adopted through experience, to implement a software quality program: cooperative assistance. We show how cooperation, education, consultation and friendly assistance can overcome this culture shock. 3 refs.« less

  19. i3Drefine software for protein 3D structure refinement and its assessment in CASP10.

    PubMed

    Bhattacharya, Debswapna; Cheng, Jianlin

    2013-01-01

    Protein structure refinement refers to the process of improving the qualities of protein structures during structure modeling processes to bring them closer to their native states. Structure refinement has been drawing increasing attention in the community-wide Critical Assessment of techniques for Protein Structure prediction (CASP) experiments since its addition in 8(th) CASP experiment. During the 9(th) and recently concluded 10(th) CASP experiments, a consistent growth in number of refinement targets and participating groups has been witnessed. Yet, protein structure refinement still remains a largely unsolved problem with majority of participating groups in CASP refinement category failed to consistently improve the quality of structures issued for refinement. In order to alleviate this need, we developed a completely automated and computationally efficient protein 3D structure refinement method, i3Drefine, based on an iterative and highly convergent energy minimization algorithm with a powerful all-atom composite physics and knowledge-based force fields and hydrogen bonding (HB) network optimization technique. In the recent community-wide blind experiment, CASP10, i3Drefine (as 'MULTICOM-CONSTRUCT') was ranked as the best method in the server section as per the official assessment of CASP10 experiment. Here we provide the community with free access to i3Drefine software and systematically analyse the performance of i3Drefine in strict blind mode on the refinement targets issued in CASP10 refinement category and compare with other state-of-the-art refinement methods participating in CASP10. Our analysis demonstrates that i3Drefine is only fully-automated server participating in CASP10 exhibiting consistent improvement over the initial structures in both global and local structural quality metrics. Executable version of i3Drefine is freely available at http://protein.rnet.missouri.edu/i3drefine/.

  20. I/O Performance Characterization of Lustre and NASA Applications on Pleiades

    NASA Technical Reports Server (NTRS)

    Saini, Subhash; Rappleye, Jason; Chang, Johnny; Barker, David Peter; Biswas, Rupak; Mehrotra, Piyush

    2012-01-01

    In this paper we study the performance of the Lustre file system using five scientific and engineering applications representative of NASA workload on large-scale supercomputing systems such as NASA s Pleiades. In order to facilitate the collection of Lustre performance metrics, we have developed a software tool that exports a wide variety of client and server-side metrics using SGI's Performance Co-Pilot (PCP), and generates a human readable report on key metrics at the end of a batch job. These performance metrics are (a) amount of data read and written, (b) number of files opened and closed, and (c) remote procedure call (RPC) size distribution (4 KB to 1024 KB, in powers of 2) for I/O operations. RPC size distribution measures the efficiency of the Lustre client and can pinpoint problems such as small write sizes, disk fragmentation, etc. These extracted statistics are useful in determining the I/O pattern of the application and can assist in identifying possible improvements for users applications. Information on the number of file operations enables a scientist to optimize the I/O performance of their applications. Amount of I/O data helps users choose the optimal stripe size and stripe count to enhance I/O performance. In this paper, we demonstrate the usefulness of this tool on Pleiades for five production quality NASA scientific and engineering applications. We compare the latency of read and write operations under Lustre to that with NFS by tracing system calls and signals. We also investigate the read and write policies and study the effect of page cache size on I/O operations. We examine the performance impact of Lustre stripe size and stripe count along with performance evaluation of file per process and single shared file accessed by all the processes for NASA workload using parameterized IOR benchmark.

  1. Use of linkage mapping and centrality analysis across habitat gradients to conserve connectivity of gray wolf populations in western North America.

    PubMed

    Carroll, Carlos; McRae, Brad H; Brookes, Allen

    2012-02-01

    Centrality metrics evaluate paths between all possible pairwise combinations of sites on a landscape to rank the contribution of each site to facilitating ecological flows across the network of sites. Computational advances now allow application of centrality metrics to landscapes represented as continuous gradients of habitat quality. This avoids the binary classification of landscapes into patch and matrix required by patch-based graph analyses of connectivity. It also avoids the focus on delineating paths between individual pairs of core areas characteristic of most corridor- or linkage-mapping methods of connectivity analysis. Conservation of regional habitat connectivity has the potential to facilitate recovery of the gray wolf (Canis lupus), a species currently recolonizing portions of its historic range in the western United States. We applied 3 contrasting linkage-mapping methods (shortest path, current flow, and minimum-cost-maximum-flow) to spatial data representing wolf habitat to analyze connectivity between wolf populations in central Idaho and Yellowstone National Park (Wyoming). We then applied 3 analogous betweenness centrality metrics to analyze connectivity of wolf habitat throughout the northwestern United States and southwestern Canada to determine where it might be possible to facilitate range expansion and interpopulation dispersal. We developed software to facilitate application of centrality metrics. Shortest-path betweenness centrality identified a minimal network of linkages analogous to those identified by least-cost-path corridor mapping. Current flow and minimum-cost-maximum-flow betweenness centrality identified diffuse networks that included alternative linkages, which will allow greater flexibility in planning. Minimum-cost-maximum-flow betweenness centrality, by integrating both land cost and habitat capacity, allows connectivity to be considered within planning processes that seek to maximize species protection at minimum cost. Centrality analysis is relevant to conservation and landscape genetics at a range of spatial extents, but it may be most broadly applicable within single- and multispecies planning efforts to conserve regional habitat connectivity. ©2011 Society for Conservation Biology.

  2. Comparing image quality of print-on-demand books and photobooks from web-based vendors

    NASA Astrophysics Data System (ADS)

    Phillips, Jonathan; Bajorski, Peter; Burns, Peter; Fredericks, Erin; Rosen, Mitchell

    2010-01-01

    Because of the emergence of e-commerce and developments in print engines designed for economical output of very short runs, there are increased business opportunities and consumer options for print-on-demand books and photobooks. The current state of these printing modes allows for direct uploading of book files via the web, printing on nonoffset printers, and distributing by standard parcel or mail delivery services. The goal of this research is to assess the image quality of print-on-demand books and photobooks produced by various Web-based vendors and to identify correlations between psychophysical results and objective metrics. Six vendors were identified for one-off (single-copy) print-on-demand books, and seven vendors were identified for photobooks. Participants rank ordered overall quality of a subset of individual pages from each book, where the pages included text, photographs, or a combination of the two. Observers also reported overall quality ratings and price estimates for the bound books. Objective metrics of color gamut, color accuracy, accuracy of International Color Consortium profile usage, eye-weighted root mean square L*, and cascaded modulation transfer acutance were obtained and compared to the observer responses. We introduce some new methods for normalizing data as well as for strengthening the statistical significance of the results. Our approach includes the use of latent mixed-effect models. We found statistically significant correlation with overall image quality and some of the spatial metrics, but correlations between psychophysical results and other objective metrics were weak or nonexistent. Strong correlation was found between psychophysical results of overall quality assessment and estimated price associated with quality. The photobook set of vendors reached higher image-quality ratings than the set of print-on-demand vendors. However, the photobook set had higher image-quality variability.

  3. SpotMetrics: An Open-Source Image-Analysis Software Plugin for Automatic Chromatophore Detection and Measurement.

    PubMed

    Hadjisolomou, Stavros P; El-Haddad, George

    2017-01-01

    Coleoid cephalopods (squid, octopus, and sepia) are renowned for their elaborate body patterning capabilities, which are employed for camouflage or communication. The specific chromatic appearance of a cephalopod, at any given moment, is a direct result of the combined action of their intradermal pigmented chromatophore organs and reflecting cells. Therefore, a lot can be learned about the cephalopod coloration system by video recording and analyzing the activation of individual chromatophores in time. The fact that adult cephalopods have small chromatophores, up to several hundred thousand in number, makes measurement and analysis over several seconds a difficult task. However, current advancements in videography enable high-resolution and high framerate recording, which can be used to record chromatophore activity in more detail and accuracy in both space and time domains. In turn, the additional pixel information and extra frames per video from such recordings result in large video files of several gigabytes, even when the recording spans only few minutes. We created a software plugin, "SpotMetrics," that can automatically analyze high resolution, high framerate video of chromatophore organ activation in time. This image analysis software can track hundreds of individual chromatophores over several hundred frames to provide measurements of size and color. This software may also be used to measure differences in chromatophore activation during different behaviors which will contribute to our understanding of the cephalopod sensorimotor integration system. In addition, this software can potentially be utilized to detect numbers of round objects and size changes in time, such as eye pupil size or number of bacteria in a sample. Thus, we are making this software plugin freely available as open-source because we believe it will be of benefit to other colleagues both in the cephalopod biology field and also within other disciplines.

  4. An empirical evaluation of software quality assurance practices and challenges in a developing country: a comparison of Nigeria and Turkey.

    PubMed

    Sowunmi, Olaperi Yeside; Misra, Sanjay; Fernandez-Sanz, Luis; Crawford, Broderick; Soto, Ricardo

    2016-01-01

    The importance of quality assurance in the software development process cannot be overemphasized because its adoption results in high reliability and easy maintenance of the software system and other software products. Software quality assurance includes different activities such as quality control, quality management, quality standards, quality planning, process standardization and improvement amongst others. The aim of this work is to further investigate the software quality assurance practices of practitioners in Nigeria. While our previous work covered areas on quality planning, adherence to standardized processes and the inherent challenges, this work has been extended to include quality control, software process improvement and international quality standard organization membership. It also makes comparison based on a similar study carried out in Turkey. The goal is to generate more robust findings that can properly support decision making by the software community. The qualitative research approach, specifically, the use of questionnaire research instruments was applied to acquire data from software practitioners. In addition to the previous results, it was observed that quality assurance practices are quite neglected and this can be the cause of low patronage. Moreover, software practitioners are neither aware of international standards organizations or the required process improvement techniques; as such their claimed standards are not aligned to those of accredited bodies, and are only limited to their local experience and knowledge, which makes it questionable. The comparison with Turkey also yielded similar findings, making the results typical of developing countries. The research instrument used was tested for internal consistency using the Cronbach's alpha, and it was proved reliable. For the software industry in developing countries to grow strong and be a viable source of external revenue, software assurance practices have to be taken seriously because its effect is evident in the final product. Moreover, quality frameworks and tools which require minimum time and cost are highly needed in these countries.

  5. A Metric-Based Validation Process to Assess the Realism of Synthetic Power Grids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Birchfield, Adam; Schweitzer, Eran; Athari, Mir

    Public power system test cases that are of high quality benefit the power systems research community with expanded resources for testing, demonstrating, and cross-validating new innovations. Building synthetic grid models for this purpose is a relatively new problem, for which a challenge is to show that created cases are sufficiently realistic. This paper puts forth a validation process based on a set of metrics observed from actual power system cases. These metrics follow the structure, proportions, and parameters of key power system elements, which can be used in assessing and validating the quality of synthetic power grids. Though wide diversitymore » exists in the characteristics of power systems, the paper focuses on an initial set of common quantitative metrics to capture the distribution of typical values from real power systems. The process is applied to two new public test cases, which are shown to meet the criteria specified in the metrics of this paper.« less

  6. A Metric-Based Validation Process to Assess the Realism of Synthetic Power Grids

    DOE PAGES

    Birchfield, Adam; Schweitzer, Eran; Athari, Mir; ...

    2017-08-19

    Public power system test cases that are of high quality benefit the power systems research community with expanded resources for testing, demonstrating, and cross-validating new innovations. Building synthetic grid models for this purpose is a relatively new problem, for which a challenge is to show that created cases are sufficiently realistic. This paper puts forth a validation process based on a set of metrics observed from actual power system cases. These metrics follow the structure, proportions, and parameters of key power system elements, which can be used in assessing and validating the quality of synthetic power grids. Though wide diversitymore » exists in the characteristics of power systems, the paper focuses on an initial set of common quantitative metrics to capture the distribution of typical values from real power systems. The process is applied to two new public test cases, which are shown to meet the criteria specified in the metrics of this paper.« less

  7. New t-gap insertion-deletion-like metrics for DNA hybridization thermodynamic modeling.

    PubMed

    D'yachkov, Arkadii G; Macula, Anthony J; Pogozelski, Wendy K; Renz, Thomas E; Rykov, Vyacheslav V; Torney, David C

    2006-05-01

    We discuss the concept of t-gap block isomorphic subsequences and use it to describe new abstract string metrics that are similar to the Levenshtein insertion-deletion metric. Some of the metrics that we define can be used to model a thermodynamic distance function on single-stranded DNA sequences. Our model captures a key aspect of the nearest neighbor thermodynamic model for hybridized DNA duplexes. One version of our metric gives the maximum number of stacked pairs of hydrogen bonded nucleotide base pairs that can be present in any secondary structure in a hybridized DNA duplex without pseudoknots. Thermodynamic distance functions are important components in the construction of DNA codes, and DNA codes are important components in biomolecular computing, nanotechnology, and other biotechnical applications that employ DNA hybridization assays. We show how our new distances can be calculated by using a dynamic programming method, and we derive a Varshamov-Gilbert-like lower bound on the size of some of codes using these distance functions as constraints. We also discuss software implementation of our DNA code design methods.

  8. Corral framework: Trustworthy and fully functional data intensive parallel astronomical pipelines

    NASA Astrophysics Data System (ADS)

    Cabral, J. B.; Sánchez, B.; Beroiz, M.; Domínguez, M.; Lares, M.; Gurovich, S.; Granitto, P.

    2017-07-01

    Data processing pipelines represent an important slice of the astronomical software library that include chains of processes that transform raw data into valuable information via data reduction and analysis. In this work we present Corral, a Python framework for astronomical pipeline generation. Corral features a Model-View-Controller design pattern on top of an SQL Relational Database capable of handling: custom data models; processing stages; and communication alerts, and also provides automatic quality and structural metrics based on unit testing. The Model-View-Controller provides concept separation between the user logic and the data models, delivering at the same time multi-processing and distributed computing capabilities. Corral represents an improvement over commonly found data processing pipelines in astronomysince the design pattern eases the programmer from dealing with processing flow and parallelization issues, allowing them to focus on the specific algorithms needed for the successive data transformations and at the same time provides a broad measure of quality over the created pipeline. Corral and working examples of pipelines that use it are available to the community at https://github.com/toros-astro.

  9. Algal bioassessment metrics for wadeable streams and rivers of Maine, USA

    USGS Publications Warehouse

    Danielson, Thomas J.; Loftin, Cynthia S.; Tsomides, Leonidas; DiFranco, Jeanne L.; Connors, Beth

    2011-01-01

    Many state water-quality agencies use biological assessment methods based on lotic fish and macroinvertebrate communities, but relatively few states have incorporated algal multimetric indices into monitoring programs. Algae are good indicators for monitoring water quality because they are sensitive to many environmental stressors. We evaluated benthic algal community attributes along a landuse gradient affecting wadeable streams and rivers in Maine, USA, to identify potential bioassessment metrics. We collected epilithic algal samples from 193 locations across the state. We computed weighted-average optima for common taxa for total P, total N, specific conductance, % impervious cover, and % developed watershed, which included all land use that is no longer forest or wetland. We assigned Maine stream tolerance values and categories (sensitive, intermediate, tolerant) to taxa based on their optima and responses to watershed disturbance. We evaluated performance of algal community metrics used in multimetric indices from other regions and novel metrics based on Maine data. Metrics specific to Maine data, such as the relative richness of species characterized as being sensitive in Maine, were more correlated with % developed watershed than most metrics used in other regions. Few community-structure attributes (e.g., species richness) were useful metrics in Maine. Performance of algal bioassessment models would be improved if metrics were evaluated with attributes of local data before inclusion in multimetric indices or statistical models. ?? 2011 by The North American Benthological Society.

  10. The Influence of Software Complexity on the Maintenance Effort: Case Study on Software Developed within Educational Process

    ERIC Educational Resources Information Center

    Radulescu, Iulian Ionut

    2006-01-01

    Software complexity is the most important software quality attribute and a very useful instrument in the study of software quality. Is one of the factors that affect most of the software quality characteristics, including maintainability. It is very important to quantity this influence and identify the means to keep it under control; by using…

  11. Measurement of Chronic Pain and Opioid Use Evaluation in Community-Based Persons with Serious Illnesses

    PubMed Central

    Naidu, Ramana K.

    2018-01-01

    Abstract Background: Chronic pain associated with serious illnesses is having a major impact on population health in the United States. Accountability for high quality care for community-dwelling patients with serious illnesses requires selection of metrics that capture the burden of chronic pain whose treatment may be enhanced or complicated by opioid use. Objective: Our aim was to evaluate options for assessing pain in seriously ill community dwelling adults, to discuss the use/abuse of opioids in individuals with chronic pain, and to suggest pain and opioid use metrics that can be considered for screening and evaluation of patient responses and quality care. Design: Structured literature review. Measurements: Evaluation of pain and opioid use assessment metrics and measures for their potential usefulness in the community. Results: Several pain and opioid assessment instruments are available for consideration. Yet, no one pain instrument has been identified as “the best” to assess pain in seriously ill community-dwelling patients. Screening tools exist that are specific to the assessment of risk in opioid management. Opioid screening can assess risk based on substance use history, general risk taking, and reward-seeking behavior. Conclusions: Accountability for high quality care for community-dwelling patients requires selection of metrics that will capture the burden of chronic pain and beneficial use or misuse of opioids. Future research is warranted to identify, modify, or develop instruments that contain important metrics, demonstrate a balance between sensitivity and specificity, and address patient preferences and quality outcomes. PMID:29091525

  12. Toward fully automated processing of dynamic susceptibility contrast perfusion MRI for acute ischemic cerebral stroke.

    PubMed

    Kim, Jinsuh; Leira, Enrique C; Callison, Richard C; Ludwig, Bryan; Moritani, Toshio; Magnotta, Vincent A; Madsen, Mark T

    2010-05-01

    We developed fully automated software for dynamic susceptibility contrast (DSC) MR perfusion-weighted imaging (PWI) to efficiently and reliably derive critical hemodynamic information for acute stroke treatment decisions. Brain MR PWI was performed in 80 consecutive patients with acute nonlacunar ischemic stroke within 24h after onset of symptom from January 2008 to August 2009. These studies were automatically processed to generate hemodynamic parameters that included cerebral blood flow and cerebral blood volume, and the mean transit time (MTT). To develop reliable software for PWI analysis, we used computationally robust algorithms including the piecewise continuous regression method to determine bolus arrival time (BAT), log-linear curve fitting, arrival time independent deconvolution method and sophisticated motion correction methods. An optimal arterial input function (AIF) search algorithm using a new artery-likelihood metric was also developed. Anatomical locations of the automatically determined AIF were reviewed and validated. The automatically computed BAT values were statistically compared with estimated BAT by a single observer. In addition, gamma-variate curve-fitting errors of AIF and inter-subject variability of AIFs were analyzed. Lastly, two observes independently assessed the quality and area of hypoperfusion mismatched with restricted diffusion area from motion corrected MTT maps and compared that with time-to-peak (TTP) maps using the standard approach. The AIF was identified within an arterial branch and enhanced areas of perfusion deficit were visualized in all evaluated cases. Total processing time was 10.9+/-2.5s (mean+/-s.d.) without motion correction and 267+/-80s (mean+/-s.d.) with motion correction on a standard personal computer. The MTT map produced with our software adequately estimated brain areas with perfusion deficit and was significantly less affected by random noise of the PWI when compared with the TTP map. Results of image quality assessment by two observers revealed that the MTT maps exhibited superior quality over the TTP maps (88% good rating of MTT as compared to 68% of TTP). Our software allowed fully automated deconvolution analysis of DSC PWI using proven efficient algorithms that can be applied to acute stroke treatment decisions. Our streamlined method also offers promise for further development of automated quantitative analysis of the ischemic penumbra. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.

  13. Software Project Management and Measurement on the World-Wide-Web (WWW)

    NASA Technical Reports Server (NTRS)

    Callahan, John; Ramakrishnan, Sudhaka

    1996-01-01

    We briefly describe a system for forms-based, work-flow management that helps members of a software development team overcome geographical barriers to collaboration. Our system, called the Web Integrated Software Environment (WISE), is implemented as a World-Wide-Web service that allows for management and measurement of software development projects based on dynamic analysis of change activity in the workflow. WISE tracks issues in a software development process, provides informal communication between the users with different roles, supports to-do lists, and helps in software process improvement. WISE minimizes the time devoted to metrics collection and analysis by providing implicit delivery of messages between users based on the content of project documents. The use of a database in WISE is hidden from the users who view WISE as maintaining a personal 'to-do list' of tasks related to the many projects on which they may play different roles.

  14. Information models of software productivity - Limits on productivity growth

    NASA Technical Reports Server (NTRS)

    Tausworthe, Robert C.

    1992-01-01

    Research into generalized information-metric models of software process productivity establishes quantifiable behavior and theoretical bounds. The models establish a fundamental mathematical relationship between software productivity and the human capacity for information traffic, the software product yield (system size), information efficiency, and tool and process efficiencies. An upper bound is derived that quantifies average software productivity and the maximum rate at which it may grow. This bound reveals that ultimately, when tools, methodologies, and automated assistants have reached their maximum effective state, further improvement in productivity can only be achieved through increasing software reuse. The reuse advantage is shown not to increase faster than logarithmically in the number of reusable features available. The reuse bound is further shown to be somewhat dependent on the reuse policy: a general 'reuse everything' policy can lead to a somewhat slower productivity growth than a specialized reuse policy.

  15. Use of Annotations for Component and Framework Interoperability

    NASA Astrophysics Data System (ADS)

    David, O.; Lloyd, W.; Carlson, J.; Leavesley, G. H.; Geter, F.

    2009-12-01

    The popular programming languages Java and C# provide annotations, a form of meta-data construct. Software frameworks for web integration, web services, database access, and unit testing now take advantage of annotations to reduce the complexity of APIs and the quantity of integration code between the application and framework infrastructure. Adopting annotation features in frameworks has been observed to lead to cleaner and leaner application code. The USDA Object Modeling System (OMS) version 3.0 fully embraces the annotation approach and additionally defines a meta-data standard for components and models. In version 3.0 framework/model integration previously accomplished using API calls is now achieved using descriptive annotations. This enables the framework to provide additional functionality non-invasively such as implicit multithreading, and auto-documenting capabilities while achieving a significant reduction in the size of the model source code. Using a non-invasive methodology leads to models and modeling components with only minimal dependencies on the modeling framework. Since models and modeling components are not directly bound to framework by the use of specific APIs and/or data types they can more easily be reused both within the framework as well as outside of it. To study the effectiveness of an annotation based framework approach with other modeling frameworks, a framework-invasiveness study was conducted to evaluate the effects of framework design on model code quality. A monthly water balance model was implemented across several modeling frameworks and several software metrics were collected. The metrics selected were measures of non-invasive design methods for modeling frameworks from a software engineering perspective. It appears that the use of annotations positively impacts several software quality measures. In a next step, the PRMS model was implemented in OMS 3.0 and is currently being implemented for water supply forecasting in the western United States at the USDA NRCS National Water and Climate Center. PRMS is a component based modular precipitation-runoff model developed to evaluate the impacts of various combinations of precipitation, climate, and land use on streamflow and general basin hydrology. The new OMS 3.0 PRMS model source code is more concise and flexible as a result of using the new framework’s annotation based approach. The fully annotated components are now providing information directly for (i) model assembly and building, (ii) dataflow analysis for implicit multithreading, (iii) automated and comprehensive model documentation of component dependencies, physical data properties, (iv) automated model and component testing, and (v) automated audit-traceability to account for all model resources leading to a particular simulation result. Experience to date has demonstrated the multi-purpose value of using annotations. Annotations are also a feasible and practical method to enable interoperability among models and modeling frameworks. As a prototype example, model code annotations were used to generate binding and mediation code to allow the use of OMS 3.0 model components within the OpenMI context.

  16. Quality evaluation of motion-compensated edge artifacts in compressed video.

    PubMed

    Leontaris, Athanasios; Cosman, Pamela C; Reibman, Amy R

    2007-04-01

    Little attention has been paid to an impairment common in motion-compensated video compression: the addition of high-frequency (HF) energy as motion compensation displaces blocking artifacts off block boundaries. In this paper, we employ an energy-based approach to measure this motion-compensated edge artifact, using both compressed bitstream information and decoded pixels. We evaluate the performance of our proposed metric, along with several blocking and blurring metrics, on compressed video in two ways. First, ordinal scales are evaluated through a series of expectations that a good quality metric should satisfy: the objective evaluation. Then, the best performing metrics are subjectively evaluated. The same subjective data set is finally used to obtain interval scales to gain more insight. Experimental results show that we accurately estimate the percentage of the added HF energy in compressed video.

  17. Software for roof defects recognition on aerial photographs

    NASA Astrophysics Data System (ADS)

    Yudin, D.; Naumov, A.; Dolzhenko, A.; Patrakova, E.

    2018-05-01

    The article presents information on software for roof defects recognition on aerial photographs, made with air drones. An areal image segmentation mechanism is described. It allows detecting roof defects – unsmoothness that causes water stagnation after rain. It is shown that HSV-transformation approach allows quick detection of stagnation areas, their size and perimeters, but is sensitive to shadows and changes of the roofing-types. Deep Fully Convolutional Network software solution eliminates this drawback. The tested data set consists of the roofing photos with defects and binary masks for them. FCN approach gave acceptable results of image segmentation in Dice metric average value. This software can be used in inspection automation of roof conditions in the production sector and housing and utilities infrastructure.

  18. ARROWSMITH-P: A prototype expert system for software engineering management

    NASA Technical Reports Server (NTRS)

    Basili, Victor R.; Ramsey, Connie Loggia

    1985-01-01

    Although the field of software engineering is relatively new, it can benefit from the use of expert systems. Two prototype expert systems were developed to aid in software engineering management. Given the values for certain metrics, these systems will provide interpretations which explain any abnormal patterns of these values during the development of a software project. The two systems, which solve the same problem, were built using different methods, rule-based deduction and frame-based abduction. A comparison was done to see which method was better suited to the needs of this field. It was found that both systems performed moderately well, but the rule-based deduction system using simple rules provided more complete solutions than did the frame-based abduction system.

  19. Quality Market: Design and Field Study of Prediction Market for Software Quality Control

    ERIC Educational Resources Information Center

    Krishnamurthy, Janaki

    2010-01-01

    Given the increasing competition in the software industry and the critical consequences of software errors, it has become important for companies to achieve high levels of software quality. While cost reduction and timeliness of projects continue to be important measures, software companies are placing increasing attention on identifying the user…

  20. Four simple recommendations to encourage best practices in research software

    PubMed Central

    Jiménez, Rafael C.; Kuzak, Mateusz; Alhamdoosh, Monther; Barker, Michelle; Batut, Bérénice; Borg, Mikael; Capella-Gutierrez, Salvador; Chue Hong, Neil; Cook, Martin; Corpas, Manuel; Flannery, Madison; Garcia, Leyla; Gelpí, Josep Ll.; Gladman, Simon; Goble, Carole; González Ferreiro, Montserrat; Gonzalez-Beltran, Alejandra; Griffin, Philippa C.; Grüning, Björn; Hagberg, Jonas; Holub, Petr; Hooft, Rob; Ison, Jon; Katz, Daniel S.; Leskošek, Brane; López Gómez, Federico; Oliveira, Luis J.; Mellor, David; Mosbergen, Rowland; Mulder, Nicola; Perez-Riverol, Yasset; Pergl, Robert; Pichler, Horst; Pope, Bernard; Sanz, Ferran; Schneider, Maria V.; Stodden, Victoria; Suchecki, Radosław; Svobodová Vařeková, Radka; Talvik, Harry-Anton; Todorov, Ilian; Treloar, Andrew; Tyagi, Sonika; van Gompel, Maarten; Vaughan, Daniel; Via, Allegra; Wang, Xiaochuan; Watson-Haigh, Nathan S.; Crouch, Steve

    2017-01-01

    Scientific research relies on computer software, yet software is not always developed following practices that ensure its quality and sustainability. This manuscript does not aim to propose new software development best practices, but rather to provide simple recommendations that encourage the adoption of existing best practices. Software development best practices promote better quality software, and better quality software improves the reproducibility and reusability of research. These recommendations are designed around Open Source values, and provide practical suggestions that contribute to making research software and its source code more discoverable, reusable and transparent. This manuscript is aimed at developers, but also at organisations, projects, journals and funders that can increase the quality and sustainability of research software by encouraging the adoption of these recommendations. PMID:28751965

  1. Four simple recommendations to encourage best practices in research software.

    PubMed

    Jiménez, Rafael C; Kuzak, Mateusz; Alhamdoosh, Monther; Barker, Michelle; Batut, Bérénice; Borg, Mikael; Capella-Gutierrez, Salvador; Chue Hong, Neil; Cook, Martin; Corpas, Manuel; Flannery, Madison; Garcia, Leyla; Gelpí, Josep Ll; Gladman, Simon; Goble, Carole; González Ferreiro, Montserrat; Gonzalez-Beltran, Alejandra; Griffin, Philippa C; Grüning, Björn; Hagberg, Jonas; Holub, Petr; Hooft, Rob; Ison, Jon; Katz, Daniel S; Leskošek, Brane; López Gómez, Federico; Oliveira, Luis J; Mellor, David; Mosbergen, Rowland; Mulder, Nicola; Perez-Riverol, Yasset; Pergl, Robert; Pichler, Horst; Pope, Bernard; Sanz, Ferran; Schneider, Maria V; Stodden, Victoria; Suchecki, Radosław; Svobodová Vařeková, Radka; Talvik, Harry-Anton; Todorov, Ilian; Treloar, Andrew; Tyagi, Sonika; van Gompel, Maarten; Vaughan, Daniel; Via, Allegra; Wang, Xiaochuan; Watson-Haigh, Nathan S; Crouch, Steve

    2017-01-01

    Scientific research relies on computer software, yet software is not always developed following practices that ensure its quality and sustainability. This manuscript does not aim to propose new software development best practices, but rather to provide simple recommendations that encourage the adoption of existing best practices. Software development best practices promote better quality software, and better quality software improves the reproducibility and reusability of research. These recommendations are designed around Open Source values, and provide practical suggestions that contribute to making research software and its source code more discoverable, reusable and transparent. This manuscript is aimed at developers, but also at organisations, projects, journals and funders that can increase the quality and sustainability of research software by encouraging the adoption of these recommendations.

  2. Objective evaluation of interior noise booming in a passenger car based on sound metrics and artificial neural networks.

    PubMed

    Lee, Hyun-Ho; Lee, Sang-Kwon

    2009-09-01

    Booming sound is one of the important sounds in a passenger car. The aim of the paper is to develop the objective evaluation method of interior booming sound. The development method is based on the sound metrics and ANN (artificial neural network). The developed method is called the booming index. Previous work maintained that booming sound quality is related to loudness and sharpness--the sound metrics used in psychoacoustics--and that the booming index is developed by using the loudness and sharpness for a signal within whole frequency between 20 Hz and 20 kHz. In the present paper, the booming sound quality was found to be effectively related to the loudness at frequencies below 200 Hz; thus the booming index is updated by using the loudness of the signal filtered by the low pass filter at frequency under 200 Hz. The relationship between the booming index and sound metric is identified by an ANN. The updated booming index has been successfully applied to the objective evaluation of the booming sound quality of mass-produced passenger cars.

  3. CrossTalk: The Journal of Defense Software Engineering. Volume 24, Number 6. November/December 2011

    DTIC Science & Technology

    2011-11-01

    Software Development.” Software Quality Professional Journal, American Society for Quality (ASQ), (March 2010) 4-14. 3. Nair, Gopalakrishnan T.R...Inspection Performance Metric”. Software Quality Professional Journal, American Society for Quality (ASQ), Volume 13, Issue 2, (March 2011) 14-26...the discovery process and are marketed by compa- nies such as Black Duck Software, OpenLogic, Palamida, and Protecode, among others.7 A number of open

  4. Image Navigation and Registration Performance Assessment Evaluation Tools for GOES-R ABI and GLM

    NASA Technical Reports Server (NTRS)

    Houchin, Scott; Porter, Brian; Graybill, Justin; Slingerland, Philip

    2017-01-01

    The GOES-R Flight Project has developed an Image Navigation and Registration (INR) Performance Assessment Tool Set (IPATS) for measuring Advanced Baseline Imager (ABI) and Geostationary Lightning Mapper (GLM) INR performance metrics in the post-launch period for performance evaluation and long term monitoring. IPATS utilizes a modular algorithmic design to allow user selection of data processing sequences optimized for generation of each INR metric. This novel modular approach minimizes duplication of common processing elements, thereby maximizing code efficiency and speed. Fast processing is essential given the large number of sub-image registrations required to generate INR metrics for the many images produced over a 24 hour evaluation period. This paper describes the software design and implementation of IPATS and provides preliminary test results.

  5. Adapting the ISO 20462 softcopy ruler method for online image quality studies

    NASA Astrophysics Data System (ADS)

    Burns, Peter D.; Phillips, Jonathan B.; Williams, Don

    2013-01-01

    In this paper we address the problem of Image Quality Assessment of no reference metrics, focusing on JPEG corrupted images. In general no reference metrics are not able to measure with the same performance the distortions within their possible range and with respect to different image contents. The crosstalk between content and distortion signals influences the human perception. We here propose two strategies to improve the correlation between subjective and objective quality data. The first strategy is based on grouping the images according to their spatial complexity. The second one is based on a frequency analysis. Both the strategies are tested on two databases available in the literature. The results show an improvement in the correlations between no reference metrics and psycho-visual data, evaluated in terms of the Pearson Correlation Coefficient.

  6. Evaluation of ride quality prediction methods for operational military helicopters

    NASA Technical Reports Server (NTRS)

    Leatherwood, J. D.; Clevenson, S. A.; Hollenbaugh, D. D.

    1984-01-01

    The results of a simulator study conducted to compare and validate various ride quality prediction methods for use in assessing passenger/crew ride comfort within helicopters are presented. Included are results quantifying 35 helicopter pilots' discomfort responses to helicopter interior noise and vibration typical of routine flights, assessment of various ride quality metrics including the NASA ride comfort model, and examination of possible criteria approaches. Results of the study indicated that crew discomfort results from a complex interaction between vibration and interior noise. Overall measures such as weighted or unweighted root-mean-square acceleration level and A-weighted noise level were not good predictors of discomfort. Accurate prediction required a metric incorporating the interactive effects of both noise and vibration. The best metric for predicting crew comfort to the combined noise and vibration environment was the NASA discomfort index.

  7. Operational excellence (six sigma) philosophy: Application to software quality assurance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lackner, M.

    1997-11-01

    This report contains viewgraphs on operational excellence philosophy of six sigma applied to software quality assurance. This report outlines the following: goal of six sigma; six sigma tools; manufacturing vs administrative processes; Software quality assurance document inspections; map software quality assurance requirements document; failure mode effects analysis for requirements document; measuring the right response variables; and questions.

  8. Auralization of NASA N+2 Aircraft Concepts from System Noise Predictions

    NASA Technical Reports Server (NTRS)

    Rizzi, Stephen A.; Burley, Casey L.; Thomas, Russel H.

    2016-01-01

    Auralization of aircraft flyover noise provides an auditory experience that complements integrated metrics obtained from system noise predictions. Recent efforts have focused on auralization methods development, specifically the process by which source noise information obtained from semi-empirical models, computational aeroacoustic analyses, and wind tunnel and flight test data, are used for simulated flyover noise at a receiver on the ground. The primary focus of this work, however, is to develop full vehicle auralizations in order to explore the distinguishing features of NASA's N+2 aircraft vis-à-vis current fleet reference vehicles for single-aisle and large twin-aisle classes. Some features can be seen in metric time histories associated with aircraft noise certification, e.g., tone-corrected perceived noise level used in the calculation of effective perceived noise level. Other features can be observed in sound quality metrics, e.g., loudness, sharpness, roughness, fluctuation strength and tone-to-noise ratio. A psychoacoustic annoyance model is employed to establish the relationship between sound quality metrics and noise certification metrics. Finally, the auralizations will serve as the basis for a separate psychoacoustic study aimed at assessing how well aircraft noise certification metrics predict human annoyance for these advanced vehicle concepts.

  9. 78 FR 16474 - Extension of the Period for Comments on the Enhancement of Quality of Software-Related Patents

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-15

    ...] Extension of the Period for Comments on the Enhancement of Quality of Software-Related Patents AGENCY... announcing the formation of a partnership with the software community to enhance the quality of software-related patents (Software Partnership), and a request for comments on the preparation of patent...

  10. Component Provider’s and Tool Developer’s Handbook. Central Archive for Reusable Defense Software (CARDS)

    DTIC Science & Technology

    1994-03-25

    metrics [DISA93b]. " The Software Engineering Institute (SET) has developed a domain analysis process (Feature-Oriented Domain Analysis - FODA ) and is...and expresses the range of variability of these decisions. 3.2.2.3 Feature Oriented Domain Analysis Feature Oriented Domain Analysis ( FODA ) is a domain...documents created in this phase. From a purely profit-oriented business point of view, a company may develop its own analysis of a government or commercial

  11. Energy Information Systems

    Science.gov Websites

    Energy Analytics Campaign > 2014-2018 Assessment of Automated M&V Methods > 2012-2018 Better Assessment of automated measurement and verification methods. Granderson, J. et al. Lawrence Berkeley . PDF, 726 KB Performance Metrics and Objective Testing Methods for Energy Baseline Modeling Software

  12. qcML: An Exchange Format for Quality Control Metrics from Mass Spectrometry Experiments*

    PubMed Central

    Walzer, Mathias; Pernas, Lucia Espona; Nasso, Sara; Bittremieux, Wout; Nahnsen, Sven; Kelchtermans, Pieter; Pichler, Peter; van den Toorn, Henk W. P.; Staes, An; Vandenbussche, Jonathan; Mazanek, Michael; Taus, Thomas; Scheltema, Richard A.; Kelstrup, Christian D.; Gatto, Laurent; van Breukelen, Bas; Aiche, Stephan; Valkenborg, Dirk; Laukens, Kris; Lilley, Kathryn S.; Olsen, Jesper V.; Heck, Albert J. R.; Mechtler, Karl; Aebersold, Ruedi; Gevaert, Kris; Vizcaíno, Juan Antonio; Hermjakob, Henning; Kohlbacher, Oliver; Martens, Lennart

    2014-01-01

    Quality control is increasingly recognized as a crucial aspect of mass spectrometry based proteomics. Several recent papers discuss relevant parameters for quality control and present applications to extract these from the instrumental raw data. What has been missing, however, is a standard data exchange format for reporting these performance metrics. We therefore developed the qcML format, an XML-based standard that follows the design principles of the related mzML, mzIdentML, mzQuantML, and TraML standards from the HUPO-PSI (Proteomics Standards Initiative). In addition to the XML format, we also provide tools for the calculation of a wide range of quality metrics as well as a database format and interconversion tools, so that existing LIMS systems can easily add relational storage of the quality control data to their existing schema. We here describe the qcML specification, along with possible use cases and an illustrative example of the subsequent analysis possibilities. All information about qcML is available at http://code.google.com/p/qcml. PMID:24760958

  13. qcML: an exchange format for quality control metrics from mass spectrometry experiments.

    PubMed

    Walzer, Mathias; Pernas, Lucia Espona; Nasso, Sara; Bittremieux, Wout; Nahnsen, Sven; Kelchtermans, Pieter; Pichler, Peter; van den Toorn, Henk W P; Staes, An; Vandenbussche, Jonathan; Mazanek, Michael; Taus, Thomas; Scheltema, Richard A; Kelstrup, Christian D; Gatto, Laurent; van Breukelen, Bas; Aiche, Stephan; Valkenborg, Dirk; Laukens, Kris; Lilley, Kathryn S; Olsen, Jesper V; Heck, Albert J R; Mechtler, Karl; Aebersold, Ruedi; Gevaert, Kris; Vizcaíno, Juan Antonio; Hermjakob, Henning; Kohlbacher, Oliver; Martens, Lennart

    2014-08-01

    Quality control is increasingly recognized as a crucial aspect of mass spectrometry based proteomics. Several recent papers discuss relevant parameters for quality control and present applications to extract these from the instrumental raw data. What has been missing, however, is a standard data exchange format for reporting these performance metrics. We therefore developed the qcML format, an XML-based standard that follows the design principles of the related mzML, mzIdentML, mzQuantML, and TraML standards from the HUPO-PSI (Proteomics Standards Initiative). In addition to the XML format, we also provide tools for the calculation of a wide range of quality metrics as well as a database format and interconversion tools, so that existing LIMS systems can easily add relational storage of the quality control data to their existing schema. We here describe the qcML specification, along with possible use cases and an illustrative example of the subsequent analysis possibilities. All information about qcML is available at http://code.google.com/p/qcml. © 2014 by The American Society for Biochemistry and Molecular Biology, Inc.

  14. Evaluating Core Quality for a Mars Sample Return Mission

    NASA Technical Reports Server (NTRS)

    Weiss, D. K.; Budney, C.; Shiraishi, L.; Klein, K.

    2012-01-01

    Sample return missions, including the proposed Mars Sample Return (MSR) mission, propose to collect core samples from scientifically valuable sites on Mars. These core samples would undergo extreme forces during the drilling process, and during the reentry process if the EEV (Earth Entry Vehicle) performed a hard landing on Earth. Because of the foreseen damage to the stratigraphy of the cores, it is important to evaluate each core for rock quality. However, because no core sample return mission has yet been conducted to another planetary body, it remains unclear as to how to assess the cores for rock quality. In this report, we describe the development of a metric designed to quantitatively assess the mechanical quality of any rock cores returned from Mars (or other planetary bodies). We report on the process by which we tested the metric on core samples of Mars analogue materials, and the effectiveness of the core assessment metric (CAM) in assessing rock core quality before and after the cores were subjected to shocking (g forces representative of an EEV landing).

  15. Preliminary comparison of landscape pattern-normalized difference vegetation index (NDVI) relationships to central plains stream conditions

    USGS Publications Warehouse

    Griffith, J.A.; Martinko, E.A.; Whistler, J.L.; Price, K.P.

    2002-01-01

    We explored relationships of water quality parameters with landscape pattern metrics (LPMs), land use-land cover (LULC) proportions, and the advanced very high resolution radiometer (AVHRR) normalized difference vegetation index (NDVI) or NDVI-derived metrics. Stream sites (271) in Nebraska, Kansas, and Missouri were sampled for water quality parameters, the index of biotic integrity, and a habitat index in either 1994 or 1995. Although a combination of LPMs (interspersion and juxtaposition index, patch density, and percent forest) within Ozark Highlands watersheds explained >60% of the variation in levels of nitrite-nitrate nitrogen and conductivity, in most cases the LPMs were not significantly correlated with the stream data. Several problems using landscape pattern metrics were noted: small watersheds having only one or two patches, collinearity with LULC data, and counterintuitive or inconsistent results that resulted from basic differences in land use-land cover patterns among ecoregions or from other factors determining water quality. The amount of variation explained in water quality parameters using multiple regression models that combined LULC and LPMs was generally lower than that from NDVI or vegetation phenology metrics derived from time-series NDVI data. A comparison of LPMs and NDVI indicated that NDVI had greater promise for monitoring landscapes for stream conditions within the study area.

  16. Preliminary comparison of landscape pattern-normalized difference vegetation index (NDVI) relationships to Central Plains stream conditions.

    PubMed

    Griffith, Jerry A; Martinko, Edward A; Whistler, Jerry L; Price, Kevin P

    2002-01-01

    We explored relationships of water quality parameters with landscape pattern metrics (LPMs), land use-land cover (LULC) proportions, and the advanced very high resolution radiometer (AVHRR) normalized difference vegetation index (NDVI) or NDVI-derived metrics. Stream sites (271) in Nebraska, Kansas, and Missouri were sampled for water quality parameters, the index of biotic integrity, and a habitat index in either 1994 or 1995. Although a combination of LPMs (interspersion and juxtaposition index, patch density, and percent forest) within Ozark Highlands watersheds explained >60% of the variation in levels of nitrite-nitrate nitrogen and conductivity, in most cases the LPMs were not significantly correlated with the stream data. Several problems using landscape pattern metrics were noted: small watersheds having only one or two patches, collinearity with LULC data, and counterintuitive or inconsistent results that resulted from basic differences in land use-land cover patterns among ecoregions or from other factors determining water quality. The amount of variation explained in water quality parameters using multiple regression models that combined LULC and LPMs was generally lower than that from NDVI or vegetation phenology metrics derived from time-series NDVI data. A comparison of LPMs and NDVI indicated that NDVI had greater promise for monitoring landscapes for stream conditions within the study area.

  17. The State of Software for Evolutionary Biology.

    PubMed

    Darriba, Diego; Flouri, Tomáš; Stamatakis, Alexandros

    2018-05-01

    With Next Generation Sequencing data being routinely used, evolutionary biology is transforming into a computational science. Thus, researchers have to rely on a growing number of increasingly complex software. All widely used core tools in the field have grown considerably, in terms of the number of features as well as lines of code and consequently, also with respect to software complexity. A topic that has received little attention is the software engineering quality of widely used core analysis tools. Software developers appear to rarely assess the quality of their code, and this can have potential negative consequences for end-users. To this end, we assessed the code quality of 16 highly cited and compute-intensive tools mainly written in C/C++ (e.g., MrBayes, MAFFT, SweepFinder, etc.) and JAVA (BEAST) from the broader area of evolutionary biology that are being routinely used in current data analysis pipelines. Because, the software engineering quality of the tools we analyzed is rather unsatisfying, we provide a list of best practices for improving the quality of existing tools and list techniques that can be deployed for developing reliable, high quality scientific software from scratch. Finally, we also discuss journal as well as science policy and, more importantly, funding issues that need to be addressed for improving software engineering quality as well as ensuring support for developing new and maintaining existing software. Our intention is to raise the awareness of the community regarding software engineering quality issues and to emphasize the substantial lack of funding for scientific software development.

  18. Quality Measures for Dialysis: Time for a Balanced Scorecard.

    PubMed

    Kliger, Alan S

    2016-02-05

    Recent federal legislation establishes a merit-based incentive payment system for physicians, with a scorecard for each professional. The Centers for Medicare and Medicaid Services evaluate quality of care with clinical performance measures and have used these metrics for public reporting and payment to dialysis facilities. Similar metrics may be used for the future merit-based incentive payment system. In nephrology, most clinical performance measures measure processes and intermediate outcomes of care. These metrics were developed from population studies of best practice and do not identify opportunities for individualizing care on the basis of patient characteristics and individual goals of treatment. The In-Center Hemodialysis (ICH) Consumer Assessment of Healthcare Providers and Systems (CAHPS) survey examines patients' perception of care and has entered the arena to evaluate quality of care. A balanced scorecard of quality performance should include three elements: population-based best clinical practice, patient perceptions, and individually crafted patient goals of care. Copyright © 2016 by the American Society of Nephrology.

  19. Reduced reference image quality assessment via sub-image similarity based redundancy measurement

    NASA Astrophysics Data System (ADS)

    Mou, Xuanqin; Xue, Wufeng; Zhang, Lei

    2012-03-01

    The reduced reference (RR) image quality assessment (IQA) has been attracting much attention from researchers for its loyalty to human perception and flexibility in practice. A promising RR metric should be able to predict the perceptual quality of an image accurately while using as few features as possible. In this paper, a novel RR metric is presented, whose novelty lies in two aspects. Firstly, it measures the image redundancy by calculating the so-called Sub-image Similarity (SIS), and the image quality is measured by comparing the SIS between the reference image and the test image. Secondly, the SIS is computed by the ratios of NSE (Non-shift Edge) between pairs of sub-images. Experiments on two IQA databases (i.e. LIVE and CSIQ databases) show that by using only 6 features, the proposed metric can work very well with high correlations between the subjective and objective scores. In particular, it works consistently well across all the distortion types.

  20. TU-H-CAMPUS-JeP1-04: Deformable Image Registration Performances in Pelvis Patients: Impact of CBCT Image Quality

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fusella, M; Loi, G; Fiandra, C

    Purpose: To investigate the accuracy and robustness, against image noise and artifacts (typical of CBCT images), of a commercial algorithm for deformable image registration (DIR), to propagate regions of interest (ROIs) in computational phantoms based on real prostate patient images. Methods: The Anaconda DIR algorithm, implemented in RayStation was tested. Two specific Deformation Vector Fields (DVFs) were applied to the reference data set (CTref) using the ImSimQA software, obtaining two deformed CTs. For each dataset twenty-four different level of noise and/or capping artifacts were applied to simulate CBCT images. DIR was performed between CTref and each deformed CTs and CBCTs.more » In order to investigate the relationship between image quality parameters and the DIR results (expressed by a logit transform of the Dice Index) a bilinear regression was defined. Results: More than 550 DIR-mapped ROIs were analyzed. The Statistical analysis states that deformation strenght and artifacts were significant prognostic factors of DIR performances, while noise appeared to have a minor role in DIR process as implemented in RayStation as expected by the image similarity metric built in the registration algorithm. Capping artifacts reveals a determinant role for the accuracy of DIR results. Two optimal values for capping artifacts were found to obtain acceptable DIR results (DICE> 075/ 0.85). Various clinical CBCT acquisition protocol were reported to evaluate the significance of the study. Conclusion: This work illustrates the impact of image quality on DIR performance. Clinical issues like Adaptive Radiation Therapy (ART) and Dose Accumulation need accurate and robust DIR software. The RayStation DIR algorithm resulted robust against noise, but sensitive to image artifacts. This result highlights the need of robustness quality assurance against image noise and artifacts in the commissioning of a DIR commercial system and underlines the importance to adopt optimized protocols for CBCT image acquisitions in ART clinical implementation.« less

Top