Sample records for solid-phase microextraction gas

  1. Identification and Quantification of Pesticides in Environmental Waters With Solid Phase Microextraction and Analysis Using Field-Portable Gas Chromatography-Mass Spectrometry

    DTIC Science & Technology

    2004-06-10

    Microextraction and Analysis using Field-Portable Gas Chromatography-Mass Spectrometry Name of Candidate: CPT Michael J. Nack...and Analysis using Field-Portable Gas Chromatography-Mass Spectrometry Beyond brief excerpts is with the permission of the copyright owner, and...Pesticides in Environmental Waters with Solid Phase Microextraction and Analysis using Field-Portable Gas Chromatography-Mass Spectrometry

  2. Discovering Volatile Chemicals from Window Weatherstripping through Solid-Phase Microextraction/Gas Chromatography-Mass Spectrometry

    ERIC Educational Resources Information Center

    Rosu, Cornelia; Cueto, Rafael; Veillion, Lucas; David, Connie; Laine, Roger A.; Russo, Paul S.

    2017-01-01

    Volatile compounds from polymeric materials such as weatherstripping were identified by solid-phase microextraction (SPME), a solvent-free analytical method, coupled to gas chromatography-mass spectrometry (GC-MS). These compounds, originating from additives and fillers used in weatherstripping processing, were mostly polycyclic aromatic…

  3. Analysis of Explosives in Soil Using Solid Phase Microextraction and Gas Chromatography: Environmental Analysis

    DTIC Science & Technology

    2006-01-01

    ENVIRONMENTAL ANALYSIS Analysis of Explosives in Soil Using Solid Phase Microextraction and Gas Chromatography Howard T. Mayfield Air Force Research...Abstract: Current methods for the analysis of explosives in soils utilize time consuming sample preparation workups and extractions. The method detection...chromatography/mass spectrometry to provide a con- venient and sensitive analysis method for explosives in soil. Keywords: Explosives, TNT, solid phase

  4. Development and Efficacy Testing of Next Generation Cyanide Antidotes

    DTIC Science & Technology

    2013-10-01

    Preparation of mDMTS A-2.2. HPLC method for DMTS determination in Micelles A-2.3. Head-space solid phase micro-extraction- gas chromatography -mass...Simultaneous determination of cyanide and thiocyanate in plasma by chemical ionization gas chromatography mass-spectrometry (CI-GC-MS). Analytical and...min. Peak integration was performed using Star Chromatography Workstation Version 6.20. A-2.3. Head-space solid phase micro-extraction- gas

  5. Quantitative Analysis of Bisphenol A Leached from Household Plastics by Solid-Phase Microextraction and Gas Chromatography-Mass Spectrometry (SPME-GC-MS)

    ERIC Educational Resources Information Center

    Johnson, Bettie Obi; Burke, Fernanda M.; Harrison, Rebecca; Burdette, Samantha

    2012-01-01

    The measurement of trace levels of bisphenol A (BPA) leached out of household plastics using solid-phase microextraction (SPME) with gas chromatography-mass spectrometry (GC-MS) is reported here. BPA is an endocrine-disrupting compound used in the industrial manufacture of polycarbonate plastic bottles and epoxy resin can liners. This experiment…

  6. SOLID PHASE MICROEXTRACTION FOR TRACE LEVEL ANALYSIS OF DISINFECTION BY-PRODUCTS

    EPA Science Inventory

    This presentation focuses on the development of a solid-phase microextraction (SPME)-gas chromatography (GC)/ion trap mass spectrometry (MS) method for the analysis of semivolatile disinfection by-products (DBPs) in drinking water in the low ug/L range. These DBPs were selected ...

  7. Determination of Plant Volatiles Using Solid Phase Microextraction GC-MS

    ERIC Educational Resources Information Center

    Van Bramer, Scott; Goodrich, Katherine R.

    2015-01-01

    This experiment combines analytical techniques of solid phase microextraction and gas chromatography-mass spectrometry with easily relatable and accessible plant volatile chemistry (floral and vegetative scents of local/available plants). The biosynthesis and structure of these chemicals are of interest in the areas of organic chemistry,…

  8. Development of an Alternative Mixed Odor Delivery Device (MODD) for Canine Training

    DTIC Science & Technology

    2017-05-10

    solid phase microextraction (SPME) and analysis by gas chromatography / mass spectrometry (GC/MS). Like the computational modeling, the laboratory...outlet was extracted by solid phase microextraction (SPME) and analyzed by gas chromatography with mass spectrometry (GC/MS). A polydimethylsiloxane...Menning and H. Ostmark, "Detection of liquid and homemade explosives: What do we need to know about their properties?," in Detection of Liquid

  9. Rapid determination of the volatile components in tobacco by ultrasound-microwave synergistic extraction coupled to headspace solid-phase microextraction with gas chromatography-mass spectrometry.

    PubMed

    Yang, Yanqin; Chu, Guohai; Zhou, Guojun; Jiang, Jian; Yuan, Kailong; Pan, Yuanjiang; Song, Zhiyu; Li, Zuguang; Xia, Qian; Lu, Xinbo; Xiao, Weiqiang

    2016-03-01

    An ultrasound-microwave synergistic extraction coupled to headspace solid-phase microextraction was first employed to determine the volatile components in tobacco samples. The method combined the advantages of ultrasound, microwave, and headspace solid-phase microextraction. The extraction, separation, and enrichment were performed in a single step, which could greatly simplify the operation and reduce the whole pretreatment time. In the developed method, several experimental parameters, such as fiber type, ultrasound power, and irradiation time, were optimized to improve sampling efficiency. Under the optimal conditions, there were 37, 36, 34, and 36 components identified in tobacco from Guizhou, Hunan, Yunnan, and Zimbabwe, respectively, including esters, heterocycles, alkanes, ketones, terpenoids, acids, phenols, and alcohols. The compound types were roughly the same while the contents were varied from different origins due to the disparity of their growing conditions, such as soil, water, and climate. In addition, the ultrasound-microwave synergistic extraction coupled to headspace solid-phase microextraction method was compared with the microwave-assisted extraction coupled to headspace solid-phase microextraction and headspace solid-phase microextraction methods. More types of volatile components were obtained by using the ultrasound-microwave synergistic extraction coupled to headspace solid-phase microextraction method, moreover, the contents were high. The results indicated that the ultrasound-microwave synergistic extraction coupled to headspace solid-phase microextraction technique was a simple, time-saving and highly efficient approach, which was especially suitable for analysis of the volatile components in tobacco. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Freeze-thaw method improves the detection of volatile compounds in insects using Headspace Solid-Phase Microextraction (HS-SPME)

    USDA-ARS?s Scientific Manuscript database

    Headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography–mass spectrometry (GC-MS) is commonly used in analyzing insect volatiles. In order to improve the detection of volatiles in insects, a freeze-thaw method was applied to insect samples before the HS-SPME-GC-MS analysis. ...

  11. Fuel spill identification using solid-phase extraction and solid-phase microextraction. 1. Aviation turbine fuels.

    PubMed

    Lavine, B K; Brzozowski, D M; Ritter, J; Moores, A J; Mayfield, H T

    2001-12-01

    The water-soluble fraction of aviation jet fuels is examined using solid-phase extraction and solid-phase microextraction. Gas chromatographic profiles of solid-phase extracts and solid-phase microextracts of the water-soluble fraction of kerosene- and nonkerosene-based jet fuels reveal that each jet fuel possesses a unique profile. Pattern recognition analysis reveals fingerprint patterns within the data characteristic of fuel type. By using a novel genetic algorithm (GA) that emulates human pattern recognition through machine learning, it is possible to identify features characteristic of the chromatographic profile of each fuel class. The pattern recognition GA identifies a set of features that optimize the separation of the fuel classes in a plot of the two largest principal components of the data. Because principal components maximize variance, the bulk of the information encoded by the selected features is primarily about the differences between the fuel classes.

  12. Identification and quantification of odours from oxobiodegradable polyethylene oxidised under a free radical flow by headspace solid-phase microextraction followed by gas chromatography-olfactometry-mass spectrometry.

    PubMed

    Wrona, Magdalena; Vera, Paula; Pezo, Davinson; Nerín, Cristina

    2017-09-01

    Recently oxobiodegradable polyethylene gained popularity as food packaging material due to its potential to reduce polymer waste. However, this type of material can release after its oxidation off-odour compounds that affect the organoleptic properties of packaged food. Odour compounds released from both polyethylene and oxobiodegradable polyethylene before and after oxidation under a free radicals flow were investigated after 1 day, 2 days and 3 days of oxidation. The samples were analysed using headspace solid phase microextraction followed by gas chromatography-mass spectrometry and headspace solid phase microextraction coupled to gas chromatography-olfactometry-mass spectrometry. Sixty-two different odorous compounds were identified. 4-methylthio-2-butanone (fruit), nonanal (fat) and 3,6-nonadienal (fat) were present in different materials before oxidation. Multiple headspace-solid phase microextraction has been used to quantify all analytes. The most abundant compound was (Z)-3-hexenyl hexanoate with a concentration range between 1.5791±0.1387µg/g and 4.8181±0.3123µg/g. Compounds such as 2-dodecenal, 2-octenal, 2-pentanol, 3-nonenal, 3,6-nonadienal, ethyl 3-methylbutanoate, ethyl octenoate, hexanone, isopropyl hexanoate, octanal were below their LOD evaluated using MS detector; however, they were detected by gas chromatography-olfactometry. The minimum LOD and LOQ were 0.011µg/g and 0.036µg/g, respectively. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Investigation of fragrance stability used in the formulation of cosmetic and hygienic products using headspace solid-phase microextraction by nanostructured materials followed by gas chromatography with mass spectrometry.

    PubMed

    Masoum, Saeed; Gholami, Ali; Ghaheri, Salehe; Bouveresse, Delphine Jouan-Rimbaud; Cordella, Christophe B Y; Rutledge, Douglas N

    2016-07-01

    A new composite coating of polypyrrole and sodium lauryl ether sulfate was electrochemically prepared on a stainless-steel wire using cyclic voltammetry. The application and performance of the fiber was evaluated for the headspace solid-phase microextraction of a fragrance in aqueous bleach samples followed by gas chromatography combined with mass spectrometry to assess the fragrance stability in this kind of household cleaning product. To obtain a stable and efficient composite coating, parameters related to the coating process such as scan rate and numbers of cycles were optimized using a central composite design. In addition, the effects of various parameters on the extraction efficiency of the headspace solid-phase microextraction process such as extraction temperature and time, ionic strength, sample volume, and stirring rate were investigated by experimental design methods using Plackett-Burman and Doehlert designs. The optimum values of 53°C and 28 min for sample temperature and time, respectively, were found through response surface methodology. Results show that the combination of polypyrrole and sodium lauryl ether sulfate in a composite form presents desirable opportunities to produce new materials to study fragrance stability by headspace solid-phase microextraction. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Application of Solid Phase Microextraction Coupled with Gas Chromatography/Mass Spectrometry as a Rapid Method for Field Sampling and Analysis of Chemical Warfare Agents and Toxic Industrial Chemicals

    DTIC Science & Technology

    2003-01-01

    PHASE MICROEXTRACTION COUPLED WITH GAS CHROMATOGRAPHY/MASS SPECTROMETRY AS A RAPID METHOD FOR FIELD SAMPLING AND ANALYSIS OF CHEMICAL WARFARE AGENTS...SAMPLING AND ANALYSIS OF CHEMICAL WARFARE AGENTS AND TOXIC INDUSTRIAL CHEMICALS 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6...GAS CHROMATOGRAPHY/MASS SPECTROMETRY AS A RAPID METHOD FOR FIELD SAMPLING AND ANALYSIS OF CHEMICAL WARFARE AGENTS AND TOXIC INDUSTRIAL CHEMICALS

  15. Characterization of three agave species by gas chromatography and solid-phase microextraction-gas chromatography-mass spectrometry.

    PubMed

    Peña-Alvarez, Araceli; Díaz, Laura; Medina, Alejandra; Labastida, Carmen; Capella, Santiago; Vera, Luz Elena

    2004-02-20

    Steam distillation (SD) extraction-solid-phase microextraction coupled to GC-MS was developed for the determination of terpenes and Bligh-Dyer extraction-derivatization coupled with GC for the determination of fatty acids such as ethyl esters were used. It was found that the three different Agave species have the same profile of fatty acids; the quantity of these compounds is different in each Agave variety. On the other hand, different terpenes were identified in the three Agave plants studied: nine in A. salmiana, eight in A. angustifolia and 32 in A. tequilana Weber var. azul.

  16. Solid-phase microextraction coupled with high performance liquid chromatography: a complementary technique to solid-phase microextraction-gas chromatography for the analysis of pesticide residues in strawberries.

    PubMed

    Wang, Z; Hennion, B; Urruty, L; Montury, M

    2000-11-01

    Solid-phase microextraction coupled with high performance liquid chromatography has been studied for the analysis of methiocarb, napropamide, fenoxycarb and bupirimate in strawberries. The strawberries were blended and centrifuged. Then, an aliquot of the resulting extracting solution was subjected to solid-phase microextraction (SPME) on a 60 microns polydimethylsiloxane/divinylbenzene (PDMS/DVB) fibre for 45 min at room temperature. The extracted pesticides on the SPME fibre were desorbed into SPME/high performance liquid chromatography (HPLC) interface for HPLC analysis with diode-array detection (DAD). The method is organic solvent-free for the whole extraction process and is simple and easy to manipulate. The detection limits were shown to be at low microgram kg-1 level and the linear response covered the range from 0.05 to 2 mg kg-1 of pesticides in strawberries with a regression coefficient larger than 0.99. A good repeatability with RSDs between 2.92 and 9.25% was obtained, depending on compounds.

  17. Solvent-modified solid-phase microextraction for the determination of diazepam in human plasma samples by capillary gas chromatography.

    PubMed

    Krogh, M; Grefslie, H; Rasmussen, K E

    1997-02-21

    This paper describes microextraction and gas chromatographic analysis of diazepam from human plasma. The method was based on immobilisation of 1.5 microliters of 1-octanol on a polyacrylate-coated fiber designed for solid-phase microextraction. The solvent-modified fibre was used to extract diazepam from the samples. The plasma sample was pre-treated to release diazepam from the protein binding. The fibre was inserted into the modified plasma sample, adjusted to pH 5.5 an internal standard was added and the mixture was carefully stirred for 4 min. The fibre with the immobilised solvent and the enriched analytes was injected into the capillary gas chromatograph. The solvent and the extracted analytes were evaporated at 300 degrees C in the split-splitless injection port of the gas chromatograph, separated on a methylsilicon capillary column and detected with a nitrogen-phosphorus detector. The method was shown to be reproducible with a detection limit of 0.10 nmol/ml in human plasma.

  18. Identification of volatile organic compounds emitted by a naturally aged book using solid-phase microextraction/gas chromatography/mass spectrometry.

    PubMed

    Lattuati-Derieux, Agnès; Bonnassies-Termes, Sylvette; Lavédrine, Bertrand

    2004-02-13

    Solid-phase microextraction (SPME) coupled to gas chromatography/mass spectrometry (GC/MS) has been applied to the analysis of volatile organic compounds emitted from a naturally aged groundwood pulp paper originating from an old book in order to access the products produced through the decomposition reactions occurring in paper upon ageing. Two different extraction methods were developed and compared: headspace SPME and contact SPME. The influence of few extraction parameters were tested in order to define the best extraction conditions. An optimised non-destructive contact SPME method was elaborated and allowed the characterisation of more than 50 individual constituents.

  19. Analysis of volatile components from Melipona beecheii geopropolis from Southeast Mexico by headspace solid-phase microextraction.

    PubMed

    Torres-González, Ahira; López-Rivera, Paulina; Duarte-Lisci, Georgina; López-Ramírez, Ángel; Correa-Benítez, Adriana; Rivero-Cruz, J Fausto

    2016-01-01

    A head space solid-phase microextraction method combined with gas chromatography-mass spectrometry was developed and optimised to extract and analyse volatile compounds of Melipona beecheii geopropolis. Seventy-three constituents were identified using this technique in the sample of geopropolis collected. The main compounds detected include β-fenchene (14.53-15.45%), styrene (8.72-9.98%), benzaldehyde (7.44-7.82%) and the most relevant volatile components presents at high level in the geopropolis were terpenoids (58.17%).

  20. Determination of 1,3-dichloro-2-propanol and 3-chloro-1,2-propandiol in soy sauce by headspace derivatization solid-phase microextraction combined with gas chromatography-mass spectrometry.

    PubMed

    Lee, Maw-Rong; Chiu, Tzu-Chun; Dou, Jianpeng

    2007-05-22

    This study proposes a method for identifying 1,3-dichloro-2-propanol and 3-chloro-1,2-propandiol in aqueous matrices by using headspace on-fiber derivatization following solid-phase microextraction combined with gas chromatography-mass spectrometry. The optimized SPME experimental procedures for extracting 1,3-dichloro-2-propanol and 3-chloro-1,2-propandiol in aqueous solutions involved a 85 microm polyacrylate-coated fiber at pH 6, a sodium chloride concentration of 0.36 g mL(-1), extraction at 50 degrees C for 15 min and desorption of analytes at 260 degrees C for 3 min. Headspace derivatization was conducted in a laboratory-made design with N-methyl-N-(trimethylsilyl)-trifluoroacetamide vapor following solid-phase microextraction by using 3 microL N-methyl-N-(trimethylsilyl)-trifluoroacetamide at an oil bath temperature of 230 degrees C for 40 s. This method had good repeatability (R.S.D.s < or = 19%, n = 8) and good linearity (r2 > or = 0.9972) for ultrapure water and soy sauce samples that were spiked with two analytes. Detection limits were obtained at the ng mL(-1). The result demonstrated that headspace on-fiber derivatization following solid-phase microextraction was a simple, fast and accurate technique for identifying trace 1,3-dichloro-2-propanol and 3-chloro-1,2-propandiol in soy sauce.

  1. A quantitative headspace-solid-phase microextraction-gas chromatography-flame ionization detector method to analyze short chain free fatty acids in rat feces.

    PubMed

    Fiorini, Dennis; Boarelli, Maria Chiara; Gabbianelli, Rosita; Ballini, Roberto; Pacetti, Deborah

    2016-09-01

    This study sought to develop and validate a quantitative method to analyze short chain free fatty acids (SCFAs) in rat feces by solid-phase microextraction and gas chromatography (SPME-GC) using the salt mixture ammonium sulfate and sodium dihydrogen phosphate as salting out agent. Conditioning and extraction time, linearity, limits of detection and quantification, repeatability, and recovery were evaluated. The proposed method allows quantification with improved sensitivity as compared with other methods exploiting SPME-GC. The method has been applied to analyze rat fecal samples, quantifying acetic, propionic, isobutyric, butyric, isopentanoic, pentanoic, and hexanoic acids. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Determination of Aroclor 1260 in soil samples by gas chromatography with mass spectrometry and solid-phase microextraction.

    PubMed

    Zhang, Mengliang; Jackson, Glen P; Kruse, Natalie A; Bowman, Jennifer R; Harrington, Peter de B

    2014-10-01

    A novel fast screening method was developed for the determination of polychlorinated biphenyls that are constituents of the commercial mixture, Aroclor 1260, in soil matrices by gas chromatography with mass spectrometry combined with solid-phase microextraction. Nonequilibrium headspace solid-phase microextraction with a 100 μm polydimethylsiloxane fiber was used to extract polychlorinated biphenyls from 0.5 g of soil matrix. The use of 2 mL of saturated potassium dichromate in 6 M sulfuric acid solution improved the reproducibility of the extractions and the mass transfer of the polychlorinated biphenyls from the soil matrix to the microextraction fiber via the headspace. The extraction time was 30 min at 100°C. The percent recoveries, which were evaluated using an Aroclor 1260 standard and liquid injection, were within the range of 54.9-65.7%. Two-way extracted ion chromatogram data were used to construct calibration curves. The relative error was <±15% and the relative standard deviation was <15%, which are respective measures of the accuracy and precision. The method was validated with certified soil samples and the predicted concentrations for Aroclor 1260 agreed with the certified values. The method was demonstrated to be linear from 10 to 1000 ng/g for Aroclor 1260 in dry soil. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Simple method for the determination of personal care product ingredients in lettuce by ultrasound-assisted extraction combined with solid-phase microextraction followed by GC-MS.

    PubMed

    Cabrera-Peralta, Jerónimo; Peña-Alvarez, Araceli

    2018-05-01

    A simple method for the simultaneous determination of personal care product ingredients: galaxolide, tonalide, oxybenzone, 4-methylbenzyliden camphor, padimate-o, 2-ethylhexyl methoxycinnamate, octocrylene, triclosan, and methyl triclosan in lettuce by ultrasound-assisted extraction combined with solid-phase microextraction followed by gas chromatography with mass spectrometry was developed. Lettuce was directly extracted by ultrasound-assisted extraction with methanol, this extract was combined with water, extracted by solid-phase microextraction in immersion mode, and analyzed by gas chromatography with mass spectrometry. Good linear relationships (25-250 ng/g, R 2  > 0.9702) and low detection limits (1.0-25 ng/g) were obtained for analytes along with acceptable precision for almost all analytes (RSDs < 20%). The validated method was applied for the determination of personal care product ingredients in commercial lettuce and lettuces grown in soil and irrigated with the analytes, identifying the target analytes in leaves and roots of the latter. This procedure is a miniaturized and environmentally friendly proposal which can be a useful tool for quality analysis in lettuce. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Multivariate study of parameters in the determination of pesticide residues in apple by headspace solid phase microextraction coupled to gas chromatography-mass spectrometry using experimental factorial design.

    PubMed

    Abdulra'uf, Lukman Bola; Tan, Guan Huat

    2013-12-15

    Solid-phase microextraction (SPME) is a solvent-less sample preparation method which combines sample preparation, isolation, concentration and enrichment into one step. In this study, multivariate strategy was used to determine the significance of the factors affecting the solid phase microextraction of pesticide residues (fenobucarb, diazinon, chlorothalonil and chlorpyrifos) using a randomised factorial design. The interactions and effects of temperature, time and salt addition on the efficiency of the extraction of the pesticide residues were evaluated using 2(3) factorial designs. The analytes were extracted with 100 μm PDMS fibres according to the factorial design matrix and desorbed into a gas chromatography-mass spectrometry detector. The developed method was applied for the analysis of apple samples and the limits of detection were between 0.01 and 0.2 μg kg(-)(1), which were lower than the MRLs for apples. The relative standard deviations (RSD) were between 0.1% and 13.37% with average recovery of 80-105%. The linearity ranges from 0.5-50 μg kg(-)(1) with correlation coefficient greater than 0.99. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Ionic liquid supported on an electrodeposited polycarbazole film for the headspace solid-phase microextraction and gas chromatography determination of aromatic esters.

    PubMed

    Feng, Yuanyuan; Zhao, Faqiong; Zeng, Baizhao

    2015-05-01

    A polycarbazole film was electrodeposited on a stainless-steel wire from a solution of N,N-dimethylformamide/propylene carbonate (1:9 v/v) containing 0.10 M carbazole and 0.10 M tetrabutylammonium perchlorate. The obtained polycarbazole fiber was immersed into an ionic liquid (1-hydroxyethyl-3-methyl imidazolium bis[(trifluoromethyl)sulfonyl]imide) solution (in dimethylsulfoxide) for 30 min, followed by drying under an infrared lamp. The resulting polycarbazole/ionic liquid fiber was applied to the headspace solid-phase microextraction and determination of aromatic esters by coupling with gas chromatography and flame ionization detection. Under the optimized conditions, the limits of detection were below 61 ng/L (S/N = 3) and the linear ranges were 0.061-500 μg/L with correlation coefficients above 0.9876. The relative standard deviations were below 4.8% (n = 5) for a single fiber, and below 9.9% for multi-fiber (n = 4). This fiber also exhibited good stability. It could be used for more than 160 times of headspace solid-phase microextraction and could withstand a high temperature up to 350°C. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. [Improvement of the determination method of benzene, toluene, ethylbenzene and xylene(BTEX) in water using activated carbon fiber solid-phase microextraction/gas chromatography-mass spectrometry(GC-MS)].

    PubMed

    Jia, Jin-ping; Feng, Xue; Fang, Neng-hu; Huang, Jia-liang

    2002-01-01

    The methods of direct injection, carbon disulfide extraction and activated carbon fiber solid-phase microextraction/GC-MS, usually used in the determination of BTEX in water matrix, are compared and discussed. Experimental data of linearity, precision and limit of detection illustrate that the last one is better than the two other methods. This method was tested by the practical sample experiments and expected to be a simple and sensitive new method for the analysis of BTEX in water.

  7. Solid phase microextraction for active or passive sampling of methyl bromide during fumigations

    USDA-ARS?s Scientific Manuscript database

    The high diffusivity and volatility of methyl bromide make it an ideal compound for Solid Phase Micro Extraction (SPME)-based sampling of air prior to gas-chromatographic quantifications. SPME fibers can be used as active methyl bromide samplers, with high capacities and an equilibrium time of 1-2 m...

  8. Headspace and direct immersion solid phase microextraction procedures for selenite determination in urine, saliva and milk by gas chromatography mass spectrometry.

    PubMed

    Kapsimali, D C; Zachariadis, G A

    2009-10-01

    Two solid phase microextraction modes were investigated and compared for their performance on the determination of selenites in various biological liquids like human urine and saliva and various types of milk. Using sodium tetraethylborate (NaBEt(4)) as ethylating reagent, selenites are converted in situ to volatile diethylselenides (DESe) in aqueous medium. The derivative is collected in situ by solid phase microextraction (SPME) using a silica fiber coated with poly(dimethylsiloxane) (PDMS) either from the headspace (HS-SPME) or directly from the liquid phase (LP-SPME) and finally determined by capillary GC/MS. Under optimum conditions of SPME, the GC separation was also optimized. Between the two examined microextraction techniques, direct immersion of the PDMS fiber in the liquid phase was proved less satisfactory. In contrast, the headspace procedure appears to be more efficient. The quantification of selenites was achieved in SIM mode with good analytical performance. A non-fat milk powder certified reference material was analyzed to evaluate the accuracy of the method. The overall precision of the method was ranged between 6.2% and 9.7%. Detection limits achieved were 0.05microgL(-1) for human urine, 0.08microgL(-1) for saliva and 0.03-0.06microgL(-1) in various milk matrices.

  9. Silicon carbide nanomaterial as a coating for solid-phase microextraction.

    PubMed

    Tian, Yu; Feng, Juanjuan; Wang, Xiuqin; Sun, Min; Luo, Chuannan

    2018-01-26

    Silicon carbide has excellent properties, such as corrosion resistance, high strength, oxidation resistance, high temperature, and so on. Based on these properties, silicon carbide was coated on stainless-steel wire and used as a solid-phase microextraction coating, and polycyclic aromatic hydrocarbons were employed as model analytes. Using gas chromatography, some important factors that affect the extraction efficiency were optimized one by one, and an analytical method was established. The analytical method showed wide linear ranges (0.1-30, 0.03-30, and 0.01-30 μg/L) with satisfactory correlation coefficients (0.9922-0.9966) and low detection limits (0.003-0.03 μg/L). To investigate the practical application of the method, rainwater and cigarette ash aqueous solution were collected as real samples for extraction and detection. The results indicate that silicon carbide has excellent application in the field of solid-phase microextraction. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Analysis of volatile organic compounds in pleural effusions by headspace solid-phase microextraction coupled with cryotrap gas chromatography and mass spectrometry.

    PubMed

    Huang, Zhongping; Zhang, Jie; Zhang, Peipei; Wang, Hong; Pan, Zaifa; Wang, Lili

    2016-07-01

    Headspace solid-phase microextraction coupled with cryotrap gas chromatography and mass spectrometry was applied to the analysis of volatile organic compounds in pleural effusions. The highly volatile organic compounds were separated successfully with high sensitivity by the employment of a cryotrap device, with the construction of a cold column head by freezing a segment of metal capillary with liquid nitrogen. A total of 76 volatile organic compounds were identified in 50 pleural effusion samples (20 malignant effusions and 30 benign effusions). Among them, 34 more volatile organic compounds were detected with the retention time less than 8 min, by comparing with the normal headspace solid-phase microextraction coupled with gas chromatography and mass spectrometry method. Furthermore, 24 volatile organic compounds with high occurrence frequency in pleural effusion samples, 18 of which with the retention time less than 8 min, were selected for the comparative analysis. The results of average peak area comparison and box-plot analysis showed that except for cyclohexanone, 2-ethyl-1-hexanol, and tetramethylbenzene, which have been reported as potential cancer biomarkers, cyclohexanol, dichloromethane, ethyl acetate, n-heptane, ethylbenzene, and xylene also had differential expression between malignant and benign effusions. Therefore, the proposed approach was valuable for the comprehensive characterization of volatile organic compounds in pleural effusions. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. The leaf volatile constituents of Isatis tinctoria by Solid-Phase Microextraction and Gas chromatography/Mass Spectrometry.

    PubMed

    Condurso, Cettina; Verzera, Antonella; Romeo, Vincenza; Ziino, Marisa; Trozzi, Alessandra; Ragusa, Salvatore

    2006-08-01

    The leaf volatile constituents of Isatis tinctoria L. (Brassicaceae) have been studied by Solid-Phase Microextraction and Gas chromatography/Mass Spectrometry (SPME/GC-MS). Seventy components were fully characterized by mass spectra, linear retention indices, and injection of standards; the average composition (ppm) as single components and classes of substances is reported. Aliphatic hydrocarbons, acids, alcohols, aldehydes and esters, aromatic aldehydes, esters and ethers, furans, isothiocyanates and thiocyanates, sulfurated compounds, nitriles, terpenes and sesquiterpenes were identified. Leaf volatiles in Isatis tinctoria L. were characterized by a high amount of isothiocyanates which accounted for about 40 % of the total volatile fraction. Isothiocyanates are important and characteristic flavour compounds in Brassica vegetables and the cancer chemo-protective attributes are recently responsible for their growing interest.

  12. Using Single Drop Microextraction for Headspace Analysis with Gas Chromatography

    NASA Astrophysics Data System (ADS)

    Riccio, Daniel; Wood, Derrick C.; Miller, James M.

    2008-07-01

    Headspace (HS) gas chromatography (GC) is commonly used to analyze samples that contain non-volatiles. In 1996, a new sampling technique called single drop microextraction, SDME, was introduced, and in 2001 it was applied to HS analysis. It is a simple technique that uses equipment normally found in the undergraduate laboratory, making it ideal for instructional use, especially to illustrate HS analysis or as an alternative to solid-phase microextraction (SPME) to which it is very similar. The basic principles and practice of HS-GC using SDME are described, including a complete review of the literature. Some possible experiments are suggested using water and N -methylpyrrolidone (NMP) as solvents.

  13. Application of Solid Phase Microextraction with Gas Chromatography-Mass Spectrometry as a Rapid, Reliable, and Safe Method for Field Sampling and Analysis of Chemical Warfare Agent Precursors

    DTIC Science & Technology

    2005-03-01

    in hair samples with analysis by GC-MS [41,42]. The research discussed here examined a polydimethylsiloxane polymer with 10% activated charcoal (PDMS...Field Sampling and Analysis of Chemical Warfare Agent Precursors” Name of Candidate: LT Douglas Parrish Doctor of Philosophy, Environmental...Microextraction with Gas Chromatography-Mass Spectrometry as a Rapid, Reliable, and Safe Method for Field Sampling and Analysis of Chemical Warfare

  14. Comparison between solid phase microextraction (SPME) and hollow fiber liquid phase microextraction (HFLPME) for determination of extractables from post-consumer recycled PET into food simulants.

    PubMed

    Oliveira, Éder Costa; Echegoyen, Yolanda; Cruz, Sandra Andrea; Nerin, Cristina

    2014-09-01

    Hollow fiber liquid phase microextraction (HFLPME) and solid phase microextraction (SPME) methods for pre-concentration of contaminants (toluene, benzophenone, tetracosane and chloroform) in food simulants were investigated. For HFLPME 1-heptanol, 2-octanone and dibutyl-ether were studied as extracting solvents. Analysis by gas chromatography coupled to mass spectrometry (GC-MS), flame ionization (GC-FID) and electron capture detectors (GC-ECD) were carried out. In addition, the methods were employed to evaluate the safety in use of a PET material after the recycling process (comprising washing, extrusion and solid state polymerization (SSP)) through extractability studies of the contaminants using 10% (v/v) ethanol in deionized water and 3% (w/v) acetic acid in deionized water as food simulants in different conditions: 10 days at 40°C and 2h at 70°C. The HFLPME preconcentration method provided increased sensitivity when compared to the SPME method and allowed to analyze concentration levels below 10 µg surrogate per kg food simulant. The results of the extractability studies showed considerable reductions after the extrusion and SSP processes and indicated the compliance with regulations for using recycled PET in contact with food. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Gas chromatographic detection of some nitro explosive compounds in soil samples after solid-phase microextraction with carbon ceramic copper nanoparticle fibers.

    PubMed

    Farhadi, Khalil; Bochani, Shayesteh; Hatami, Mehdi; Molaei, Rahim; Pirkharrati, Hossein

    2014-07-01

    In this research, a new solid-phase microextraction fiber based on carbon ceramic composites with copper nanoparticles followed by gas chromatography with flame ionization detection was applied for the extraction and determination of some nitro explosive compounds in soil samples. The proposed method provides an overview of trends related to synthesis of solid-phase microextraction sorbents and their applications in preconcentration and determination of nitro explosives. The sorbents were prepared by mixing of copper nanoparticles with a ceramic composite produced by mixture of methyltrimethoxysilane, graphite, methanol, and hydrochloric acid. The prepared sorbents were coated on copper wires by dip-coating method. The prepared nanocomposites were evaluated statistically and provided better limits of detection than the pure carbon ceramic. The limit of detection of the proposed method was 0.6 μg/g with a linear response over the concentration range of 2-160 μg/g and square of correlation coefficient >0.992. The new proposed fiber has been demonstrated to be a suitable, inexpensive, and sensitive candidate for extraction of nitro explosive compounds in contaminated soil samples. The constructed fiber can be used more than 100 times without the need for surface generation. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Rapid Screening of Volatile Organic Compounds from Aframomum danielli Seeds Using Headspace Solid Phase Microextraction Coupled to Gas Chromatography Mass Spectrometry

    PubMed Central

    Njobeh, Patrick B.; Gbashi, Sefater; Adegoke, Gabriel O.; Dubery, Ian A.

    2018-01-01

    Volatile organic compounds (VOCs) derived from plants have been used in the fragrance industry since time immemorial. Herein we report on the rapid screening of VOCs from seeds of ripe Aframomum danielli (family, Zingiberaceae) using a polydimethylsiloxane fibre headspace solid phase microextraction coupled to a gas chromatography mass spectrometry (SPME-GC/MS) instrument. Portions of 0.25, 0.35, and 0.50 g of ground sample were weighed and extraction of volatile organic compounds (VOCs) was achieved using a 100 μm polydimethylsiloxane solid phase microextraction (PDMS SPME) fibre, with the equilibrium time of 40 minutes and extraction temperature of 50°C; the following compounds with their respective relative abundances were obtained as the top ten most abundant and annotated ones using NIST, Wiley, and Fragrances Libraries: eucalyptol (58%); β-pinene (22%); α-pinene (7.5%); α-terpineol (4%), α-terpinyl acetate (2%); α-bergamotene (1%); pinocarveol (0.39%); α-copaene (0.35%); caryophyllene (0.34); and β-bisabolene (0.31%). These compounds have been reported elsewhere in the literature and listed in the Fragrances Library, incorporated into the Saturn QP2020 GCMS Solution® software used for their analysis. PMID:29849643

  17. Characterization of the Key Aroma Compounds in Proso Millet Wine Using Headspace Solid-Phase Microextraction and Gas Chromatography-Mass Spectrometry.

    PubMed

    Liu, Jingke; Zhao, Wei; Li, Shaohui; Zhang, Aixia; Zhang, Yuzong; Liu, Songyan

    2018-02-20

    The volatile compounds in proso millet wine were extracted by headspace solid-phase microextraction (85 μm polyacrylate (PA), 100 μm polydimethylsiloxane (PDMS), 75 μm Carboxen (CAR)/PDMS, and 50/30 μm divinylbenzene (DVB)/CAR/PDMS fibers), and analyzed using gas chromatography-mass spectrometry; the odor characteristics and intensities were analyzed by the odor activity value (OAV). Different sample preparation factors were used to optimize this method: sample amount, extraction time, extraction temperature, and content of NaCl. A total of 64 volatile compounds were identified from the wine sample, including 14 esters, seven alcohols, five aldehydes, five ketones, 12 benzene derivatives, 12 hydrocarbons, two terpenes, three phenols, two acids, and two heterocycles. Ethyl benzeneacetate, phenylethyl alcohol, and benzaldehyde were the main volatile compounds found in the samples. According to their OAVs, 14 volatile compounds were determined to be odor-active compounds (OAV > 1), and benzaldehyde, benzeneacetaldehyde, 1-methyl-naphthalene, 2-methyl-naphthalene, and biphenyl were the prominent odor-active compounds (OAV > 50), having a high OAV. Principal component analysis (PCA) showed the difference of distribution of the 64 volatile compounds and 14 odor-active compounds with four solid-phase microextraction (SPME) fibers.

  18. A novel poly(3,4-ethylenedioxythiophene)-ionic liquid composite coating for the headspace solid-phase microextraction and gas chromatography determination of several alcohols in soft drinks.

    PubMed

    Wu, Mian; Zhang, Haibo; Zhao, Faqiong; Zeng, Baizhao

    2014-11-19

    A novel poly(3,4-ethylenedioxythiophene)-ionic liquid (i.e., 1-hydroxyethyl-3-methyl imidazolium-bis[(trifluoromethyl)sulfonyl]imide) composite film was electrodeposited on a Pt wire for headspace solid-phase microextraction. The film showed nodular structure and had large specific surface. In addition, it displayed high thermal stability (up to 300°C) and durable property (could be used for more than 200 times). Coupled with gas chromatography-flame ionization detection, the resulting fiber was applied to the headspace solid-phase microextraction and determination of several alcohols (i.e., linalool, nonanol, terpineol, geraniol, decanol and dodecanol). It presented higher extraction capability in comparison with the poly(3,4-ethylenedioxythiophene) and commercial polydimethylsiloxane/divinylbenzene fiber. Under the optimized conditions, the linear ranges exceeded three magnitudes with correlation coefficients above 0.9952 and the low limits of detection were 34.2-81.3ng L(-1). For different alcohols the repeatabilities (defined as RSD) were <5.8% and <7.8% for single fiber (n=5) and fiber-to-fiber (n=4), respectively. The proposed method was applied to the determination of these alcohols in real samples with acceptable recoveries from 81.1% to 106.6%. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Advanced analytical techniques for the extraction and characterization of plant-derived essential oils by gas chromatography with mass spectrometry.

    PubMed

    Waseem, Rabia; Low, Kah Hin

    2015-02-01

    In recent years, essential oils have received a growing interest because of the positive health effects of their novel characteristics such as antibacterial, antifungal, and antioxidant activities. For the extraction of plant-derived essential oils, there is the need of advanced analytical techniques and innovative methodologies. An exhaustive study of hydrodistillation, supercritical fluid extraction, ultrasound- and microwave-assisted extraction, solid-phase microextraction, pressurized liquid extraction, pressurized hot water extraction, liquid-liquid extraction, liquid-phase microextraction, matrix solid-phase dispersion, and gas chromatography (one- and two-dimensional) hyphenated with mass spectrometry for the extraction through various plant species and analysis of essential oils has been provided in this review. Essential oils are composed of mainly terpenes and terpenoids with low-molecular-weight aromatic and aliphatic constituents that are particularly important for public health. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Determination of some volatile compounds in alcoholic beverage by headspace solid-phase microextraction gas chromatography - mass spectrometry

    NASA Astrophysics Data System (ADS)

    Schmutzer, G.; Avram, V.; Feher, I.; David, L.; Moldovan, Z.

    2012-02-01

    The volatile composition of alcoholic beverage was studied by headspace solid-phase microextraction (HSSPME) method and gas chromatography - mass spectrometry (GC-MS). Some volatile compounds, such as alcohols, esters, terpenes and other are mainly responsible for the flavor of fortified wines and their amounts specify the quality of the alcoholic beverages. From this perspective it is interesting to develop a rapid, selective and sensitive analytical method suitable for simultaneous quantification of the main molecules being responsible for the organoleptic characteristic of alcoholic beverages. Vermouth fortified drink was analyzed in order to characterize the volatile profile. Using the HS-SPME/GC-MS a number of twenty-six volatile compounds from a commercial market alcoholic beverage were identified. The most abundant compounds were m-thymol, o-thymol and eugenol, alongside of the ethyl ester compounds.

  1. Identification of volatiles in leaves of Alpinia zerumbet 'Variegata' using headspace solid-phase microextraction-gas chromatography-mass spectrometry.

    PubMed

    Chen, Jian Yan; Ye, Zheng Mei; Huang, Tian Yi; Chen, Xiao Dan; Li, Yong Yu; Wu, Shao Hua

    2014-07-01

    Alpinia zerumbet 'Variegata' is an aromatic medicinal plant, its foliage producing an intense, unique fragrant odor. This study identified 46 volatile compounds in the leaf tissue of this plant using headspace solid-phase microextraction-gas chromatography-mass spectrometry (HS-SPME-GC-MS). The major compounds included 1, 8-cineole (43.5%), p-cymene (14.7%), humulene (5.5%), camphor (5.3%), linalool (4.7%), (E)-methyl cinnamate (3.8%), gamma-cadinene (3.3%), humulene oxide II (2.1%) and a-terpineol (1.5%). The majority of the volatiles were terpenoids of which oxygenated monoterpenes were the most abundant, accounting for 57.2% of the total volatiles. Alcohols made up the largest (52.8%) and aldehydes the smallest (0.2%) portions of the volatiles. Many bioactive compounds were present in the volatiles.

  2. A star-shaped polythiophene dendrimer coating for solid-phase microextraction of triazole agrochemicals.

    PubMed

    Abolghasemi, Mir Mahdi; Habibiyan, Rahim; Jaymand, Mehdi; Piryaei, Marzieh

    2018-02-14

    A nanostructured star-shaped polythiophene dendrimer was prepared and used as a fiber coating for headspace solid phase microextraction of selected triazolic pesticides (tebuconazole, hexaconazole, penconazole, diniconazole, difenoconazole, triticonazole) from water samples. The dendrimer with its large surface area was characterized by thermogravimetric analysis, UV-Vis spectroscopy and field emission scanning electron microscopy. It was placed on a stainless steel wire for use in SPME. The experimental conditions for fiber coating, extraction, stirring rate, ionic strength, pH value, desorption temperature and time were optimized. Following thermal desorption, the pesticides were quantified by GC-MS. Under optimum conditions, the repeatability (RSD) for one fiber (for n = 3) ranges from 4.3 to 5.6%. The detection limits are between 8 and 12 pg mL -1 . The method is fast, inexpensive (in terms of equipment), and the fiber has high thermal stability. Graphical abstract Schematic presentation of a nanostructured star-shaped polythiophene dendrimer for use in headspace solid phase microextraction of the triazolic pesticides (tebuconazole, hexaconazole, penconazole, diniconazole, difenoconazole, triticonazole). They were then quantified by gas chromatography-mass spectrometry.

  3. Simple fabrication of solid phase microextraction fiber employing nitrogen-doped ordered mesoporous polymer by in situ polymerization.

    PubMed

    Zheng, Juan; Liang, Yeru; Liu, Shuqin; Jiang, Ruifen; Zhu, Fang; Wu, Dingcai; Ouyang, Gangfeng

    2016-01-04

    A combination of nitrogen-doped ordered mesoporous polymer (NOMP) and stainless steel wires led to highly sensitive, selective, and stable solid phase microextraction (SPME) fibers by in situ polymerization for the first time. The ordered structure of synthesized NOMP coating was illustrated by transmission electron microscopy (TEM) and X-ray diffraction (XRD), and microscopy analysis by scanning electron microscopy (SEM) confirmed a homogenous morphology of the NOMP-coated fiber. The NOMP-coated fiber was further applied for the extraction of organochlorine pesticides (OCPs) with direct-immersion solid-phase microextraction (DI-SPME) method followed by gas chromatography-mass spectrometry (GC-MS) quantification. Under the optimized conditions, low detection limits (0.023-0.77 ng L(-1)), a wide linear range (9-1500 ng L(-1)), good repeatability (3.5-8.1%, n=6) and excellent reproducibility (1.5-8.3%, n=3) were achieved. Moreover, the practical feasibility of the proposed method was evaluated by determining OCPs in environmental water samples with satisfactory recoveries. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Gas chromatographic determination of polycyclic aromatic hydrocarbons in water and smoked rice samples after solid-phase microextraction using multiwalled carbon nanotube loaded hollow fiber.

    PubMed

    Matin, Amir Abbas; Biparva, Pourya; Gheshlaghi, Mohammad

    2014-12-29

    A novel solid-phase microextraction fiber was prepared based on multiwalled carbon nanotubes (MWCNTs) loaded on hollow fiber membrane pores. Stainless steel wire was used as unbreakable support. The major advantages of the proposed fiber are its (a) high reproducibility due to the uniform structure of the hollow fiber membranes, (b) high extraction capacity related to the porous structure of the hollow fiber and outstanding adsorptive characteristics of MWCNTs. The proposed fiber was applied for the microextraction of five representative polycyclic aromatic hydrocarbons (PAHs) from aqueous media (river and hubble-bubble water) and smoked rice samples followed by gas chromatographic determination. Analytical merits of the method, including high correlation coefficients [(0.9963-0.9992) and (0.9982-0.9999)] and low detection limits [(9.0-13.0ngL(-1)) and (40.0-150.0ngkg(-1))] for water and rice samples, respectively, made the proposed method suitable for the ultra-trace determination of PAHs. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Microextraction techniques for the determination of volatile and semivolatile organic compounds from plants: a review.

    PubMed

    Yang, Cui; Wang, Juan; Li, Donghao

    2013-10-17

    Vegetables and fruits are necessary for human health, and traditional Chinese medicine that uses plant materials can cure diseases. Thus, understanding the composition of plant matrix has gained increased attention in recent years. Since plant matrix is very complex, the extraction, separation and quantitation of these chemicals are challenging. In this review we focus on the microextraction techniques used in the determination of volatile and semivolatile organic compounds (such as esters, alcohols, aldehydes, hydrocarbons, ketones, terpenes, sesquiterpene, phenols, acids, plant secondary metabolites and pesticides) from plants (e.g., fruits, vegetables, medicinal plants, tree leaves, etc.). These microextraction techniques include: solid phase microextraction (SPME), stir-bar sorptive extraction (SBSE), single drop microextraction (SDME), hollow fiber liquid phase microextraction (HF-LPME), dispersive liquid liquid microextraction (DLLME), and gas purge microsyringe extraction (GP-MSE). We have taken into consideration papers published from 2008 to the end of January 2013, and provided critical and interpretative review on these techniques, and formulated future trends in microextraction for the determination of volatile and semivolatile compounds from plants. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Multivariate analysis of the volatile components in tobacco based on infrared-assisted extraction coupled to headspace solid-phase microextraction and gas chromatography-mass spectrometry.

    PubMed

    Yang, Yanqin; Pan, Yuanjiang; Zhou, Guojun; Chu, Guohai; Jiang, Jian; Yuan, Kailong; Xia, Qian; Cheng, Changhe

    2016-11-01

    A novel infrared-assisted extraction coupled to headspace solid-phase microextraction followed by gas chromatography with mass spectrometry method has been developed for the rapid determination of the volatile components in tobacco. The optimal extraction conditions for maximizing the extraction efficiency were as follows: 65 μm polydimethylsiloxane-divinylbenzene fiber, extraction time of 20 min, infrared power of 175 W, and distance between the infrared lamp and the headspace vial of 2 cm. Under the optimum conditions, 50 components were found to exist in all ten tobacco samples from different geographical origins. Compared with conventional water-bath heating and nonheating extraction methods, the extraction efficiency of infrared-assisted extraction was greatly improved. Furthermore, multivariate analysis including principal component analysis, hierarchical cluster analysis, and similarity analysis were performed to evaluate the chemical information of these samples and divided them into three classifications, including rich, moderate, and fresh flavors. The above-mentioned classification results were consistent with the sensory evaluation, which was pivotal and meaningful for tobacco discrimination. As a simple, fast, cost-effective, and highly efficient method, the infrared-assisted extraction coupled to headspace solid-phase microextraction technique is powerful and promising for distinguishing the geographical origins of the tobacco samples coupled to suitable chemometrics. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Fabrication of polyaniline-coated halloysite nanotubes by in situ chemical polymerization as a solid-phase microextraction coating for the analysis of volatile organic compounds in aqueous solutions.

    PubMed

    Abolghasemi, Mir Mahdi; Arsalani, Naser; Yousefi, Vahid; Arsalani, Mahmood; Piryaei, Marzieh

    2016-03-01

    We have synthesized an organic-inorganic polyaniline-halloysite nanotube composite by an in situ polymerization method. This nanocomposite is immobilized on a stainless-steel wire and can be used as a fiber coating for solid-phase microextraction. It was found that our new solid-phase microextraction fiber is an excellent adsorbent for the extraction of some volatile organic compounds in aqueous samples in combination with gas chromatography and mass spectrometry. The coating can be prepared easily, is mechanically stable, and exhibits relatively high thermal stability. It is capable of extracting phenolic compounds from water samples. Following thermal desorption, the phenols were quantified by gas chromatography with mass spectrometry. The effects of extraction temperature, extraction time, sample ionic strength, stirring rate, pH, desorption temperature and desorption time were studied. Under optimal conditions, the repeatability for one fiber (n = 5), expressed as the relative standard deviation, is between 6.2 and 9.1%. The detection limits range from 0.005 to 4 ng/mL. The method offers the advantage of being simple to use, with a shorter analysis time, lower cost of equipment and higher thermal stability of the fiber in comparison to conventional methods of analysis. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Application of solid-phase microextraction with gas chromatography and mass spectrometry for the early detection of active moulds on historical woollen objects.

    PubMed

    Sawoszczuk, Tomasz; Syguła-Cholewińska, Justyna; Del Hoyo-Meléndez, Julio M

    2017-02-01

    The goal of this work was to determine the microbial volatile organic compounds emitted by moulds growing on wool in search of particular volatiles mentioned in the literature as indicators of active mould growth. The keratinolytically active fungi were inoculated on two types of media: (1) samples of wool placed on broths, and (2) on broths containing amino acids that are elements of the structure of keratin. All samples were prepared inside 20 mL vials (closed system). In the first case (1) the broths did not contain any sources of organic carbon, nitrogen, or sulfur, i.e. wool was the only nutrient for the moulds. A third type of sample was historical wool prepared in a Petri dish without a broth and inoculated with a keratinolytically active mould (open system). The microbial volatiles emitted by moulds were sampled with the headspace solid-phase microextraction method. Volatiles extracted on solid-phase microextraction fibers were analyzed in a gas chromatography with mass spectrometry system. Qualitative and quantitative analyses of chromatograms were carried out in search of indicators of metabolic activity. The results showed that there are three groups of volatiles that can be used for the detection of active forms of moulds on woollen objects. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Solid-phase microextraction may catalize hydrogenation when using hydrogen as carrier in gas chromatography.

    PubMed

    Fiorini, D; Boarelli, M C

    2016-07-01

    When hydrogen is used as carrier gas, carbon-carbon double bonds may be hydrogenated in the hot gas chromatograph (GC) injector if introduced by solid-phase microextraction (SPME). SPME fibers coated with polydimethylsiloxane (PDMS)/carboxen/divinylbenzene (DVB), PDMS/carboxen, polyacrylate, PDMS/DVB and PDMS on fused silica, stableflex or metal alloy core have been tested with fatty acid methyl esters (FAMEs) from olive oil. Using coatings containing DVB, hydrogenation took place with high conversion rates (82.0-92.9%) independently of the core material. With all fibers having a metal core, hydrogenation was observed to a certain extent (27.4-85.3%). PDMS, PDMS/carboxen and polyacrylate coated fibers with a fused silica or stableflex core resulted in negligible hydrogenation (0.2-2.5%). The occurrence of hydrogenation was confirmed also with other substances containing carbon-carbon double bonds (n-alkenes, alkenoic acids, mono- and polyunsaturated fatty acid methyl and ethyl esters). Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Determination of cocaine, benzoylecgonine and cocaethylene in human hair by solid-phase microextraction and gas chromatography-mass spectrometry.

    PubMed

    de Toledo, Fernanda Crossi Pereira; Yonamine, Mauricio; de Moraes Moreau, Regina Lucia; Silva, Ovandir Alves

    2003-12-25

    The present work describes a highly precise and sensitive method developed to detect cocaine (COC), benzoylecgonine (BE, its main metabolite) and cocaethylene (CE, transesterification product of the coingestion of COC with ethanol) in human head hair samples. The method was based on an alkylchloroformate derivatization of benzoylecgonine and the extraction of the analytes by solid-phase microextraction (SPME). Gas chromatography-mass spectrometry (GC-MS) was used to identify and quantify the analytes in selected ion monitoring mode (SIM). The limits of quantification and detection (LOQ and LOD) were: 0.1 ng/mg for COC and CE, and 0.5 ng/mg for BE. Good inter- and intra-assay precision was observed. The dynamic range of the assay was 0.1-50 ng/mg. The method is not time consuming and was shown to be easy to perform.

  11. Determination of volatile monophenols in beer using acetylation and headspace solid-phase microextraction in combination with gas chromatography and mass spectrometry.

    PubMed

    Sterckx, Femke L; Saison, Daan; Delvaux, Freddy R

    2010-08-31

    Monophenols are widely spread compounds contributing to the flavour of many foods and beverages. They are most likely present in beer, but so far, little is known about their influence on beer flavour. To quantify these monophenols in beer, we optimised a headspace solid-phase microextraction method coupled to gas chromatography-mass spectrometry. To improve their isolation from the beer matrix and their chromatographic properties, the monophenols were acetylated using acetic anhydride and KHCO(3) as derivatising agent and base catalyst, respectively. Derivatisation conditions were optimised with attention for the pH of the reaction medium. Additionally, different parameters affecting extraction efficiency were optimised, including fibre coating, extraction time and temperature and salt addition. Afterwards, we calibrated and validated the method successfully and applied it for the analysis of monophenols in beer samples. 2010 Elsevier B.V. All rights reserved.

  12. Characterization of Aronia melanocarpa volatiles by headspace-solid-phase microextraction (HS-SPME), simultaneous distillation/extraction (SDE), and gas chromatography-olfactometry (GC-O) methods.

    PubMed

    Kraujalytė, Vilma; Leitner, Erich; Venskutonis, Petras Rimantas

    2013-05-22

    The profiles of volatile constituents of berry fruit of two Aronia melanocarpa genotypes were evaluated by headspace-solid-phase microextraction (HS-SPME), simultaneous distillation and extraction (SDE), and gas chromatography-olfactometry (GC-O). In total, 74 volatile compounds were identified in chokeberry juice, 3-penten-2-one, 3,9-epoxy-p-menth-1-ene, and benzaldehyde being the most abundant constituents; however, their percentage concentrations were remarkably different in the HS-SPME and SDE profiles. Twenty two aroma-active compounds were detected and characterized by the trained panelists in HS-SPME using GC-O detection frequency analysis. Olfactometry revealed that ethyl-2-methyl butanoate, ethyl-3-methyl butanoate, ethyl decanoate ("fruity" aroma notes), nonanal ("green" notes), unidentified compound possessing "moldy" odor, and some other volatiles may be very important constituents in formation of chokeberry aroma of both analyzed plant cultivars.

  13. An Effective Method to Detect Volatile Intermediates Generated in the Bioconversion of Coal to Methane by Gas Chromatography-Mass Spectrometry after In-Situ Extraction Using Headspace Solid-Phase Micro-Extraction under Strict Anaerobic Conditions.

    PubMed

    Liu, Jianmin; Wang, Baoyu; Tai, Chao; Wu, Li; Zhao, Han; Guan, Jiadong; Chen, Linyong

    2016-01-01

    Bioconversion of coal to methane has gained increased attention in recent decades because of its economic and environmental advantages. However, the mechanism of this process is difficult to study in depth, partly because of difficulties associated with the analysis of intermediates generated in coal bioconversion. In this investigation, we report on an effective method to analyze volatile intermediates generated in the bioconversion of coal under strict anaerobic conditions. We conduct in-situ extraction of intermediates using headspace solid-phase micro-extraction followed by detection by gas chromatography-mass spectrometry. Bioconversion simulation equipment was modified and combined with a solid-phase micro-extraction device. In-situ extraction could be achieved by using the combined units, to avoid a breakdown in anaerobic conditions and to maintain the experiment continuity. More than 30 intermediates were identified qualitatively in the conversion process, and the variation in trends of some typical intermediates has been discussed. Volatile organic acids (C2-C7) were chosen for a quantitative study of the intermediates because of their importance during coal bioconversion to methane. Fiber coating, extraction time, and solution acidity were optimized in the solid-phase micro-extraction procedure. The pressure was enhanced during the bioconversion process to investigate the influence of headspace pressure on analyte extraction. The detection limits of the method ranged from 0.0006 to 0.02 mmol/L for the volatile organic acids and the relative standard deviations were between 4.6% and 11.5%. The volatile organic acids (C2-C7) generated in the bioconversion process were 0.01-1.15 mmol/L with a recovery range from 80% to 105%. The developed method is useful for further in-depth research on the bioconversion of coal to methane.

  14. An Effective Method to Detect Volatile Intermediates Generated in the Bioconversion of Coal to Methane by Gas Chromatography-Mass Spectrometry after In-Situ Extraction Using Headspace Solid-Phase Micro-Extraction under Strict Anaerobic Conditions

    PubMed Central

    Liu, Jianmin; Wang, Baoyu; Tai, Chao; Wu, Li; Zhao, Han; Guan, Jiadong; Chen, Linyong

    2016-01-01

    Bioconversion of coal to methane has gained increased attention in recent decades because of its economic and environmental advantages. However, the mechanism of this process is difficult to study in depth, partly because of difficulties associated with the analysis of intermediates generated in coal bioconversion. In this investigation, we report on an effective method to analyze volatile intermediates generated in the bioconversion of coal under strict anaerobic conditions. We conduct in-situ extraction of intermediates using headspace solid-phase micro-extraction followed by detection by gas chromatography-mass spectrometry. Bioconversion simulation equipment was modified and combined with a solid-phase micro-extraction device. In-situ extraction could be achieved by using the combined units, to avoid a breakdown in anaerobic conditions and to maintain the experiment continuity. More than 30 intermediates were identified qualitatively in the conversion process, and the variation in trends of some typical intermediates has been discussed. Volatile organic acids (C2–C7) were chosen for a quantitative study of the intermediates because of their importance during coal bioconversion to methane. Fiber coating, extraction time, and solution acidity were optimized in the solid-phase micro-extraction procedure. The pressure was enhanced during the bioconversion process to investigate the influence of headspace pressure on analyte extraction. The detection limits of the method ranged from 0.0006 to 0.02 mmol/L for the volatile organic acids and the relative standard deviations were between 4.6% and 11.5%. The volatile organic acids (C2–C7) generated in the bioconversion process were 0.01–1.15 mmol/L with a recovery range from 80% to 105%. The developed method is useful for further in-depth research on the bioconversion of coal to methane. PMID:27695055

  15. Fast determination of octinoxate and oxybenzone uv filters in swimming pool waters by gas chromatography/mass spectrometry after solid-phase microextraction.

    PubMed

    Yılmazcan, Ö; Kanakaki, C; Izgi, B; Rosenberg, E

    2015-07-01

    A fast gas chromatography/mass spectrometry method was developed and validated for the analysis of the potential endocrine disrupters octinoxate and oxybenzone in swimming pool water samples based on the solvent-free solid-phase microextraction technique. The low-pressure gas chromatography/mass spectrometry method used for the fast identification of UV filter substances was compared to a conventional method in terms of sensitivity and speed. The fast method proposed resulted in 2 min runs, leading to an eightfold decrease in the total analysis time and a sevenfold improvement in detection limits. The main parameters affecting the solid-phase microextraction process were also studied in detail and the optimized conditions were as follows: fiber coating, polyacrylate; extraction mode, direct immersion; extraction temperature, 25°C; sample volume, 5 mL; extraction time 45 min; pH 6.5. Under the optimized conditions, a linear response was obtained in the concentration range of 0.5-25 μg/L with correlation coefficients in the range 0.990-0.999. The limits of detection were 0.17-0.29 μg/L, and the recoveries were 80-83%. Combined method uncertainty was assessed and found to be less than 7% for both analytes for concentrations equal to or higher than 5 μg/L. Pool water samples were analyzed to demonstrate the applicability of the proposed method. Neither octinoxate nor oxybenzone were detected in the swimming pool water samples at concentrations above the respective limits of detection. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Application of headspace solid-phase microextraction followed by gas chromatography coupled with mass spectrometry to determine esters of carboxylic acids and other volatile compounds in Dermestes maculatus and Dermestes ater lipids.

    PubMed

    Cerkowniak, Magdalena; Boguś, Mieczysława I; Włóka, Emilia; Stepnowski, Piotr; Gołębiowski, Marek

    2018-02-01

    A constant problem in veterinary medicine, human healthcare, agriculture, forestry and horticulture is the large number of pests, and the lack of effective methods to combat them which cause no harm to the rest of the environment. It is recommended and desired to reduce the use of chemicals and increase the use of agents based on knowledge acquired in the fields of biology, chemistry and agrochemicals. To learn the defense mechanisms of insects we should consider not only the site of their physiological ability to protect against external factors (cuticle), but also the possibility of chemical protection, formed by all compounds on the surface and in the body of insects. In this study, a procedure was developed to determine the esters of carboxylic acids in insect lipids. Headspace solid-phase microextraction was followed by gas chromatography coupled with gas spectrometry. First, the best conditions were selected for the analysis to obtain the best chromatographic separation. An RTx-5 column was used for this purpose. Polydimethylsiloxane/divinylbenzene (PDMS/DVB) and polyacrylate fibers were used to isolate acid esters. PDMS/DVB fiber achieved the best conditions for the extraction; the extraction time was 50 min, the extraction temperature was 105°C and the desorption time was 10 min at 230°C. These solid-phase microextraction conditions were used to analyze volatile compounds extracted from insects belonging to the Dermestidae family. Copyright © 2017 John Wiley & Sons, Ltd.

  17. Characterization of Fish Sauce Aroma Impact Compounds Using GC-MS, SPME-Osme-GCO, and Stevens' Power Law Exponents

    USDA-ARS?s Scientific Manuscript database

    The objectives of this study were to characterize volatile compounds and to determine the characteristic aromas associated with impact compounds in 4 fish sauces using solid-phase micro-extraction, gas chromatography-mass spectrometry, Osme, and gas chromatography olfactometry (SPME-Osme-GCO) couple...

  18. Analysis of Volatile Fragrance and Flavor Compounds by Headspace Solid Phase Microextraction and GC-MS: An Undergraduate Instrumental Analysis Experiment

    NASA Astrophysics Data System (ADS)

    Galipo, Randolph C.; Canhoto, Alfredo J.; Walla, Michael D.; Morgan, Stephen L.

    1999-02-01

    A senior-level undergraduate laboratory experiment that demonstrates the use of solid-phase microextraction (SPME) and capillary gas chromatography-mass spectrometry (GC-MS) was developed for the identification of volatile compounds in consumer products. SPME minimizes sample preparation and concentrates volatile analytes in a solvent-free manner. Volatile flavor and fragrance compounds were extracted by SPME from the headspace of vials containing shampoos, chewing gums, and perfumes and analyzed by GC-MS. Headspace SPME was shown to be more sensitive than conventional headspace analysis of similar samples performed with an airtight syringe. Analysis times were less than 30 min, allowing multiple analyses to be performed in a typical laboratory class period.

  19. A novel sorbent based on carbon nanotube/amino-functionalized sol-gel for the headspace solid-phase microextraction of α-bisabolol from medicinal plant samples using experimental design.

    PubMed

    Yarazavi, Mina; Noroozian, Ebrahim

    2018-02-13

    A novel sol-gel coating on a stainless-steel fiber was developed for the first time for the headspace solid-phase microextraction and determination of α-bisabolol with gas chromatography and flame ionization detection. The parameters influencing the efficiency of solid-phase microextraction process, such as extraction time and temperature, pH, and ionic strength, were optimized by the experimental design method. Under optimized conditions, the linear range was between 0.0027 and 100 μg/mL. The relative standard deviations determined at 0.01 and 1.0 μg/mL concentration levels (n = 3), respectively, were as follows: intraday relative standard deviations 3.4 and 3.3%; interday relative standard deviations 5.0 and 4.3%; and fiber-to-fiber relative standard deviations 6.0 and 3.5%. The relative recovery values were 90.3 and 101.4% at 0.01 and 1.0 μg/mL spiking levels, respectively. The proposed method was successfully applied to various real samples containing α-bisabolol. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Development of a simple and sensitive method for the characterization of odorous waste gas emissions by means of solid-phase microextraction (SPME) and GC-MS/olfactometry.

    PubMed

    Kleeberg, K K; Liu, Y; Jans, M; Schlegelmilch, M; Streese, J; Stegmann, R

    2005-01-01

    A solid-phase microextraction (SPME) method has been developed for the extraction of odorous compounds from waste gas. The enriched compounds were characterized by gas chromatography-mass spectrometry (GC-MS) and gas chromatography followed by simultaneous flame ionization detection and olfactometry (GC-FID/O). Five different SPME fiber coatings were tested, and the carboxen/polydimethylsiloxane (CAR/PDMS) fiber showed the highest ability to extract odorous compounds from the waste gas. Furthermore, parameters such as exposure time, desorption temperature, and desorption time have been optimized. The SPME method was successfully used to characterize an odorous waste gas from a fat refinery prior to and after waste gas treatment in order to describe the treatment efficiency of the used laboratory scale plant which consisted of a bioscrubber/biofilter combination and an activated carbon adsorber. The developed method is a valuable approach to provide detailed information of waste gas composition and complements existing methods for the determination of odors. However, caution should be exercised if CAR/PDMS fibers are used for the quantification of odorous compounds in multi-component matrices like waste gas emissions since the relative affinity of each analyte was shown to differ according to the total amount of analytes present in the sample.

  1. Preparation of a novel hyperbranched carbosilane-silica hybrid coating for trace amount detection by solid phase microextraction/gas chromatography.

    PubMed

    Chen, Guowen; Li, Wenjie; Zhang, Chen; Zhou, Chuanjian; Feng, Shengyu

    2012-09-21

    Phenyl-ended hyperbranched carbosilane (HBC) is synthesized and immobilized onto the inner wall of a fused silica capillary column using a sol-gel process. The hybrid coating layer formed is used as a stationary phase for gas chromatography (GC) and as an adsorption medium for solid phase microextraction (SPME). Trifluoroacetic acid, as a catalyst in this process, helps produce a homogeneous hybrid coating layer. This result is beneficial for better column chromatographic performances, such as high efficiency and high resolution. Extraction tests using the novel hybrid layer show an extraordinarily large adsorption capacity and specific adsorption behavior for aromatic compounds. A 1 ppm trace level detectability is obtained with the SPME/GC work model when both of the stationary phase and adsorption layer bear a hyperbranched structure. A large amount of phenyl groups and a low viscosity of hyperbranched polymers contribute to these valuable properties, which are important to environment and safety control, wherein detection sensitivity and special adsorption behavior are usually required. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Speciation analysis of mercury by solid-phase microextraction and multicapillary gas chromatography hyphenated to inductively coupled plasma-time-of-flight-mass spectrometry.

    PubMed

    Jitaru, Petru; Adams, Freddy C

    2004-11-05

    This paper reports the development of an analytical approach for speciation analysis of mercury at ultra-trace levels on the basis of solid-phase microextraction and multicapillary gas chromatography hyphenated to inductively coupled plasma-time-of-flight mass spectrometry. Headspace solid-phase microextraction with a carboxen/polydimethylsyloxane fiber is used for extraction/preconcentration of mercury species after derivatization with sodium tetraethylborate and subsequent volatilization. Isothermal separation of methylmercury (MeHg), inorganic mercury (Hg2+) and propylmercury (PrHg) used as internal standard is achieved within a chromatographic run below 45 s without the introduction of spectral skew. Method detection limits (3 x standard deviation criteria) calculated for 10 successive injections of the analytical reagent blank are 0.027 pg g(-1) (as metal) for MeHg and 0.27 pg g(-1) for Hg2+. The repeatability (R.S.D., %) is 3.3% for MeHg and 3.8% for Hg2+ for 10 successive injections of a standard mixture of 10pg. The method accuracy for MeHg and total mercury is validated through the analysis of marine and estuarine sediment reference materials. A comparison of the sediment data with those obtained by a purge-and-trap injection (PTI) method is also addressed. The analytical procedure is illustrated with some results for the ultra-trace level analysis of ice from Antarctica for which the accuracy is assessed by spike recovery experiments.

  3. Detection of volatile spoilage metabolites in fermented cucumbers using nontargeted, comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry (GCxGC-TOFMS)

    USDA-ARS?s Scientific Manuscript database

    A nontargeted, comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry (GCxGC-TOFMS) method was developed for the analysis of fermented cucumber volatiles before and after anaerobic spoilage. Volatiles extracted by solid-phase microextraction were separated on a polyethyle...

  4. Ultrasensitive Speciation Analysis of Mercury in Rice by Headspace Solid Phase Microextraction Using Porous Carbons and Gas Chromatography-Dielectric Barrier Discharge Optical Emission Spectrometry.

    PubMed

    Lin, Yao; Yang, Yuan; Li, Yuxuan; Yang, Lu; Hou, Xiandeng; Feng, Xinbin; Zheng, Chengbin

    2016-03-01

    Rice consumption is a primary pathway for human methylmercury (MeHg) exposure in inland mercury mining areas of Asia. In addition, the use of iodomethane, a common fumigant that significantly accelerates the methylation of mercury in soil under sunlight, could increase the MeHg exposure from rice. Conventional hyphenated techniques used for mercury speciation analysis are usually too costly for most developing countries. Consequently, there is an increased interest in the development of sensitive and inexpensive methods for the speciation of mercury in rice. In this work, gas chromatography (GC) coupled to dielectric barrier discharge optical emission spectrometry (DBD-OES) was developed for the speciation analysis of mercury in rice. Prior to GC-DBD-OES analysis, mercury species were derivatized to their volatile species with NaBPh4 and preconcentrated by headspace solid phase microextraction using porous carbons. Limits of detection of 0.5 μg kg(-1) (0.16 ng), 0.75 μg kg(-1) (0.24 ng), and 1.0 μg kg(-1) (0.34 ng) were obtained for Hg(2+), CH3Hg(+), and CH3CH2Hg(+), respectively, with relative standard deviations (RSDs) better than 5.2% and 6.8% for one fiber or fiber-to-fiber mode, respectively. Recoveries of 90-105% were obtained for the rice samples, demonstrating the applicability of the proposed technique. Owing to the small size, low power, and low gas consumption of DBD-OES as well as efficient extraction of mercury species by porous carbons headspace solid phase micro-extraction, the proposed technique provides several advantages including compactness, cost-effectiveness, and potential to couple with miniature GC to accomplish the field speciation of mercury in rice compared to conventional hyphenated techniques.

  5. Electropolymerized fluorinated aniline-based fiber for headspace solid-phase microextraction and gas chromatographic determination of benzaldehyde in injectable pharmaceutical formulations.

    PubMed

    Mohammadi, Ali; Mohammadi, Somayeh; Bayandori Moghaddam, Abdolmajid; Masoumi, Vahideh; Walker, Roderick B

    2014-10-01

    In this study, a simple method was developed and validated to detect trace levels of benzaldehyde in injectable pharmaceutical formulations by solid-phase microextraction coupled with gas chromatography-flame ionization detector. Polyaniline was electrodeposited on a platinum wire in trifluoroacetic acid solvent by cyclic voltammetry technique. This fiber shows high thermal and mechanical stability and high performance in extraction of benzaldehyde. Extraction and desorption time and temperature, salt effect and gas chromatography parameters were optimized as key parameters. At the optimum conditions, the fiber shows good linearity between peak area ratio of benzaldehyde/3-chlorobenzaldehyde and benzaldehyde concentration in the range of 50-800 ng/mL with percent relative standard deviation values ranging from 0.75 to 8.64% (n = 3). The limits of quantitation and detection were 50 and 16 ng/mL, respectively. The method has the requisite selectivity, sensitivity, accuracy and precision to assay benzaldehyde in injectable pharmaceutical dosage forms. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Characterization of solid-phase microextraction and gas chromatography for the analysis of gasoline tracers in different microenvironments.

    PubMed

    Ceballos, Diana; Zielinska, Barbara; Fujita, Eric; Sagebiel, John

    2007-03-01

    Gasoline tracers were collected on solid-phase microextraction (SPME) fibers and analyzed by capillary gas chromatography with photoionization detector (GC/PID). This was part of a larger study to quantify personal exposure to motor vehicle gasoline evaporative and combustive emissions in high-end exposure microenvironments (MEs). The SPME fiber selected for this application was a 75-microm carboxen/polydimethylsiloxane. Sequential 10-min samples were collected for measurement of benzene, toluene, ethylbenzene, and ortho-, meta-, and para-xylene in different MEs in Atlanta, GA, in summer 2002 and Reno, NV, in spring 2003. Field calibrations were performed with certified gas standards in 1-L Tedlar bags for varying concentrations and exposure times. SPME detection limits were approximately 0.2 ppbv with a precision of 3-17% and accuracy of 30%. A dynamic system was designed for temperature and relative humidity calibrations, with corrections for the effects of these variables performed when necessary. SPME data compared satisfactorily with integrated canister samples, continuous PID, and field portable mass spectrometer data.

  7. Analysis of Volatile Components of Cape Gooseberry (Physalis peruviana L.) Grown in Turkey by HS-SPME and GC-MS

    PubMed Central

    2014-01-01

    Volatile components in cape gooseberry fruit at ripe stage were collected using headspace-solid phase microextraction, and analyzed by gas chromatography-mass spectrometry. Three solid phase microextraction fiber coatings (DVB/CAR/PDMS, CAR/PDMS, and PDMS/DVB) were tested for evaluation of volatile compounds. DVB/CAR/PDMS fiber showed a strong extraction capacity for volatile compounds and produced the best result in case of total peak areas. A total of 133 volatile compounds were identified in fruit pulp; among them 1-hexanol (6.86%), eucalyptol (6.66%), ethyl butanoate (6.47%), ethyl octanoate (4.01%), ethyl decanoate (3.39%), 4-terpineol (3.27%), and 2-methyl-1-butanol (3.10%) were the major components in the sample extracts. PMID:24741358

  8. Analysis of volatile components of cape gooseberry (Physalis peruviana L.) grown in Turkey by HS-SPME and GC-MS.

    PubMed

    Yilmaztekin, Murat

    2014-01-01

    Volatile components in cape gooseberry fruit at ripe stage were collected using headspace-solid phase microextraction, and analyzed by gas chromatography-mass spectrometry. Three solid phase microextraction fiber coatings (DVB/CAR/PDMS, CAR/PDMS, and PDMS/DVB) were tested for evaluation of volatile compounds. DVB/CAR/PDMS fiber showed a strong extraction capacity for volatile compounds and produced the best result in case of total peak areas. A total of 133 volatile compounds were identified in fruit pulp; among them 1-hexanol (6.86%), eucalyptol (6.66%), ethyl butanoate (6.47%), ethyl octanoate (4.01%), ethyl decanoate (3.39%), 4-terpineol (3.27%), and 2-methyl-1-butanol (3.10%) were the major components in the sample extracts.

  9. Optimization of headspace solid-phase microextraction by means of an experimental design for the determination of methyl tert.-butyl ether in water by gas chromatography-flame ionization detection.

    PubMed

    Dron, Julien; Garcia, Rosa; Millán, Esmeralda

    2002-07-19

    A procedure for determination of methyl tert.-butyl ether (MTBE) in water by headspace solid-phase microextraction (HS-SPME) has been developed. The analysis was carried out by gas chromatography with flame ionization detection. The extraction procedure, using a 65-microm poly(dimethylsiloxane)-divinylbenzene SPME fiber, was optimized following experimental design. A fractional factorial design for screening and a central composite design for optimizing the significant variables were applied. Extraction temperature and sodium chloride concentration were significant variables, and 20 degrees C and 300 g/l were, respectively chosen for the best extraction response. With these conditions, an extraction time of 5 min was sufficient to extract MTBE. The calibration linear range for MTBE was 5-500 microg/l and the detection limit 0.45 microg/l. The relative standard deviation, for seven replicates of 250 microg/l MTBE in water, was 6.3%.

  10. Determination of roasted pistachio (Pistacia vera L.) key odorants by headspace solid-phase microextraction and gas chromatography-olfactometry.

    PubMed

    Aceña, Laura; Vera, Luciano; Guasch, Josep; Busto, Olga; Mestres, Montserrat

    2011-03-23

    Key odorants in roasted pistachio nuts have been determined for the first time. Two different pistachio varieties (Fandooghi and Kerman) have been analyzed by means of headspace solid-phase microextraction (HS-SPME) and gas chromatography-olfactometry (GCO). The aroma extract dilution analyses (AEDA) applied have revealed 46 and 41 odor-active regions with a flavor dilution (FD) factor≥64 for the Fandooghi and the Kerman varieties, respectively, and 39 of them were related to precisely identified compounds. These included esters, pyrazines, aldehydes, acids, furans, and phenols. The results show that the Fandooghi variety presents, not only more odor-active regions but also higher FD factors than the Kerman variety that can lead to the conclusion that the first variety has a richer aromatic profile than the second one. The descriptive sensory analysis (DSA) showed that the roasted, chocolate/coffee, and nutty attributes were rated significantly higher in the Fandooghi variety, whereas the green attribute was significantly higher in the Kerman one.

  11. Quantitative analysis of 2-furfural and 5-methylfurfural in different Italian vinegars by headspace solid-phase microextraction coupled to gas chromatography-mass spectrometry using isotope dilution.

    PubMed

    Giordano, Lucia; Calabrese, Roberto; Davoli, Enrico; Rotilio, Domenico

    2003-10-31

    A new method was developed for the determination of 2-furfural (2-F) and 5-methylfurfural (5-MF), two products of Maillard reaction in vinegar, with head-space solid-phase microextraction (HS-SPME) coupled to gas chromatography-mass spectrometry (GC-MS). A divinylbenzene (DVB)/carboxen (CAR)/polydimethylsiloxane (PDMS) fibre was used and SPME conditions were optimised, studying ionic strength effect, temperature effect and adsorption time. Both analytes were determined by calibration established on 2-furfural-d4 (2-F-d4). The method showed good linearity in the range studied (from 16 to 0.12 mg/l), with a regression coefficient r2 of 0.9999. Inter-batch precision and accuracy were found between 14.9 and 6.0% and between -11.7 and 0.2%, respectively. Detection limit was 15 microg/l. The method is simple and accurate and it has been applied to a series of balsamic and non-balsamic vinegars.

  12. Determination of Lactones in Wines by Headspace Solid-Phase Microextraction and Gas Chromatography Coupled with Mass Spectrometry

    PubMed Central

    Pérez-Olivero, S. J.; Pérez-Pont, M. L.; Conde, J. E.; Pérez-Trujillo, J. P.

    2014-01-01

    Application of headspace solid-phase microextraction (HS-SPME) coupled with high-resolution gas chromatographic (HRGC) analysis was studied for determining lactones in wines. Six different SPME fibers were tested, and the influence of different factors such as temperature and time of desorption, ionic strength, time of extraction, content of sugar, ethanol, tannins and anthocyanins, and pH and influence of SO2 were studied. The proposed HS-SPME-GC method is an appropriate technique for the quantitative analysis of γ-butyrolactone, γ-hexalactone, trans-whiskey lactone, γ-octalactone, cis-whiskey lactone, γ-nonalactone, γ-decalactone, δ-decalactone, and γ-undecalactone in wines. Method reproducibility and repeatability ranged between 0.6 and 5.2% for all compounds. Detection limit for γ-butyrolactone was 0.17 mg/L and a few μg/L for the rest of the compounds. The optimized method has been applied to several wine samples. PMID:24782943

  13. Simple determination of fluoride in biological samples by headspace solid-phase microextraction and gas chromatography-tandem mass spectrometry.

    PubMed

    Kwon, Sun-Myung; Shin, Ho-Sang

    2015-08-14

    A simple and convenient method to detect fluoride in biological samples was developed. This method was based on derivatization with 2-(bromomethyl)naphthalene, headspace solid phase microextraction (HS-SPME) in a vial, and gas chromatography-tandem mass spectrometric detection. The HS-SPME parameters were optimized as follows: selection of CAR/PDMS fiber, 0.5% 2-(bromomethyl)naphthalene, 250 mg/L 15-crown-5-ether as a phase transfer catalyst, extraction and derivatization temperature of 95 °C, heating time of 20 min and pH of 7.0. Under the established conditions, the lowest limits of detection were 9 and 11 μg/L in 1.0 ml of plasma and urine, respectively, and the intra- and inter-day relative standard deviation was less than 7.7% at concentrations of 0.1 and 1.0 mg/L. The calibration curve showed good linearity of plasma and urine with r=0.9990 and r=0.9992, respectively. This method is simple, amenable to automation and environmentally friendly. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Simultaneous Determination of Parathion, Malathion, Diazinon, and Pirimiphos Methyl in Dried Medicinal Plants Using Solid-Phase Microextraction Fibre Coated with Single-Walled Carbon Nanotubes

    PubMed Central

    Ahmadkhaniha, Reza; Samadi, Nasrin; Salimi, Mona; Sarkhail, Parisa; Rastkari, Noushin

    2012-01-01

    A reliable and sensitive headspace solid-phase microextraction gas chromatography-mass spectrometry method for simultaneous determination of different organophosphorus pesticides in dried medicinal plant samples is described. The analytes were extracted by single-walled carbon nanotubes as a new solid-phase microextraction adsorbent. The developed method showed good performance. For diazinon and pirimiphos methyl calibration, curves were linear (r 2 ≥ 0.993) over the concentration ranges from 1.5 to 300 ng g−1, and the limit of detection at signal-to-noise ratio of 3 was 0.3 ng g−1. For parathion and malathion, the linear range and limit of detection were 2.5–300 (r 2 ≥ 0.991) and 0.5 ng g−1, respectively. In addition, a comparative study between the single-walled carbon nanotubes and a commercial polydimethylsiloxane fibre for the determination of target analytes was carried out. Single-walled carbon nanotubes fibre showed higher extraction capacity, better thermal stability (over 350°C), and longer lifespan (over 250 times) than the commercial polydimethylsiloxane fibre. The developed method was successfully applied to determine target organophosphorus pesticides in real samples. PMID:22645439

  15. Graphene oxide decorated with silver nanoparticles as a coating on a stainless-steel fiber for solid-phase microextraction.

    PubMed

    Wang, Licheng; Hou, Xiudan; Li, Jubai; Liu, Shujuan; Guo, Yong

    2015-07-01

    A novel graphene oxide decorated with silver nanoparticles coating on a stainless-steel fiber for solid-phase microextraction was prepared. Scanning electron microscopy and X-ray photoelectron spectroscopy were used to characterize the coating surface and showed that silver nanoparticles were dispersed on the wrinkled graphene oxide surface. Coupled to gas chromatography with flame ionization detection, the extraction abilities of the fiber for polycyclic aromatic hydrocarbons were examined in the headspace solid-phase microextraction mode. The extraction parameters including adsorption time, adsorption temperature, salt concentration, desorption time and desorption temperature were investigated. Under the optimized condition, wide linearity with low limits of detection from 2 to 10 ng/L was obtained. The relative standard deviations for single-fiber repeatability and fiber-to-fiber reproducibility were less than 10.6 and 17.5%, respectively. The enrichment factors were from 1712.5 to 4503.7, showing the fiber has good extraction abilities. Moreover, the fiber exhibited a good stability and could be reused for more than 120 times. The established method was also applied for determination of polycyclic aromatic hydrocarbons in two real water samples and the recoveries of analytes ranged from 84.4-116.3% with relative standard deviations less than 16.2%. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Influence of maturity and ripening on aroma volatiles and flavor in avocado

    USDA-ARS?s Scientific Manuscript database

    Changes in aroma volatiles were determined using solid phase microextraction (SPME) and gas chromatography in ripe avocados (Persea americana Mill.) throughout an eight-month maturation period and related to the sensory properties of the fruit. As maturation progressed sensory panelists found the li...

  17. Comparison of methods for determining volatile compounds in cheese, milk, and whey powder

    USDA-ARS?s Scientific Manuscript database

    Solid phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS) are commonly used for qualitative and quantitative analysis of volatile compounds in various dairy products, but selecting the proper procedures presents challenges. Heat is applied to drive volatiles from the samp...

  18. EVALUATION OF SOLID PHASE MICROEXTRACTION FOR THE ANALYSIS OF HYDROPHILIC COMPOUNDS

    EPA Science Inventory

    Two commercially available solid phase microextractions (SPME) fibers, polyacrylate and carboxem/polydimethylsiloxane (PDMS), were evaluated for their ability to extract hydrophilic compounds from drinking water. Conditions, such as desorption time, desorption temperature, sample...

  19. Simultaneous determination of polycyclic aromatic hydrocarbons and their chlorination by-products in drinking water and the coatings of water pipes by automated solid-phase microextraction followed by gas chromatography-mass spectrometry.

    PubMed

    Tillner, Jocelyn; Hollard, Caroline; Bach, Cristina; Rosin, Christophe; Munoz, Jean-François; Dauchy, Xavier

    2013-11-08

    In this study, an automated method for the simultaneous determination of polycyclic aromatic hydrocarbons (PAHs) and their chlorination by-products in drinking water was developed based on online solid-phase microextraction-gas chromatography-mass spectrometry. The main focus was the optimisation of the solid-phase microextraction step. The influence of the agitation rate, type of fibre, desorption time, extraction time, extraction temperature, desorption temperature, and solvent addition was examined. The method was developed and validated using a mixture of 17 PAHs, 11 potential chlorination by-products (chlorinated and oxidised PAHs) and 6 deuterated standards. The limit of quantification was 10 ng/L for all target compounds. The validated method was used to analyse drinking water samples from three different drinking water distribution networks and the presumably coal tar-based pipe coatings of two pipe sections. A number of PAHs were detected in all three networks although individual compositions varied. Several PAH chlorination by-products (anthraquinone, fluorenone, cyclopenta[d,e,f]phenanthrenone, 3-chlorofluoranthene, and 1-chloropyrene) were also found, their presence correlating closely with that of their respective parent compounds. Their concentrations were always below 100 ng/L. In the coatings, all PAHs targeted were detected although concentrations varied between the two coatings (76-12,635 mg/kg and 12-6295 mg/kg, respectively). A number of chlorination by-products (anthraquinone, fluorenone, cyclopenta[d,e,f]phenanthrenone, 3-chlorofluoranthene, and 1-chloropyrene) were also detected (from 40 to 985 mg/kg), suggesting that the reaction of PAHs with disinfectant agents takes place in the coatings and not in the water phase after migration. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Comparison of methods for determining volatile compounds in milk, cheese, and whey powder

    USDA-ARS?s Scientific Manuscript database

    Solid phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS) are commonly used for qualitative and quantitative analysis of volatile compounds in various dairy products, but conditions have to be adjusted for optimal SPME release while not generating new compounds that are abs...

  1. Identification of volatiles from waste larval rearing media that attract gravid screwworm flies to oviposit

    USDA-ARS?s Scientific Manuscript database

    The waste product of the artificial larval rearing media of the primary screwworm, Cochliomyia hominivorax, attracts gravid female screwworm flies to oviposit. The volatile component of this waste product was collected using solid phase microextraction techniques and subjected to gas chromatography-...

  2. Growth dynamics of specific spoilage organisms and associated spoilage biomarkers in chicken breast stored aerobically

    USDA-ARS?s Scientific Manuscript database

    This study was performed to identify and quantify selected volatile spoilage biomarkers in a headspace over chicken breast using solid phase microextraction (SPME) combined with gas chromatography-mass spectrometry-flame ionization detectors (GC-MS/FID). The chicken breast samples were aerobically s...

  3. Solid-phase microextraction method for the determination of hexanal in hazelnuts as an indicator of the interaction of active packaging materials with food aroma compounds.

    PubMed

    Pastorelli, S; Valzacchi, S; Rodriguez, A; Simoneau, C

    2006-11-01

    Fatty foods are susceptible to lipid oxidation resulting in deterioration of product quality due to the generation of off-flavours. Hexanal is a good indicator of rancidity. Therefore, a method based on solid-phase microextraction (SPME) coupled to gas chromatograph with flame ionization detection was developed to determine hexanal formation in hazelnuts during storage. Optimum conditions were as follows: carboxen-polydimethylsiloxane 75 microm fibre, extraction time 10 min, equilibrium time 10 min and equilibrium temperature 60 degrees C. The effect of oxygen scavengers on the oxidation process was also evaluated by measuring hexanal formation in hazelnuts stored with/without oxygen absorber sachets. Oxygen scavengers were shown to reduce oxidation; however, analysis of the sachet revealed that other volatile compounds from the headspace were also absorbed.

  4. Comparison of mass spectrometry-based electronic nose and solid phase microextraction gas chromatography-mass spectrometry technique to assess infant formula oxidation.

    PubMed

    Fenaille, François; Visani, Piero; Fumeaux, René; Milo, Christian; Guy, Philippe A

    2003-04-23

    Two headspace techniques based on mass spectrometry detection (MS), electronic nose, and solid phase microextraction coupled to gas chromatography-mass spectrometry (SPME-GC/MS) were evaluated for their ability to differentiate various infant formula powders based on changes of their volatiles upon storage. The electronic nose gave unresolved MS fingerprints of the samples gas phases that were further submitted to principal component analysis (PCA). Such direct MS recording combined to multivariate treatment enabled a rapid differentiation of the infant formulas over a 4 week storage test. Although MS-based electronic nose advantages are its easy-to-use aspect and its meaningful data interpretation obtained with a high throughput (100 samples per 24 h), its greatest disadvantage is that the present compounds could not be identified and quantified. For these reasons, a SPME-GC/MS measurement was also investigated. This technique allowed the identification of saturated aldehydes as the main volatiles present in the headspace of infant milk powders. An isotope dilution assay was further developed to quantitate hexanal as a potential indicator of infant milk powder oxidation. Thus, hexanal content was found to vary from roughly 500 and 3500 microg/kg for relatively non-oxidized and oxidized infant formulas, respectively.

  5. Solid-phase microextraction for the determination of volatile compounds in the spoilage of raw ground beef.

    PubMed

    Pérez, Rosa Ana; Rojo, Maria Dolores; González, Gema; De Lorenzo, Cristina

    2008-01-01

    A method using solid-phase microextraction (SPME) and gas chromatography/mass spectrometry was developed and applied to the determination of volatile compounds generated in meat, at different times, from ground beef stored under refrigeration. Selection of the extractive fiber, extraction time, and headspace (HS) or direct extraction was optimized for the determination of volatile compounds from ground meat. Various fibers were investigated, and carboxen/polydimethylsiloxane was selected for these analyses. The HS analysis of the solid sample by HS-SPME produced a higher volatile signal than did direct-SPME. The meat samples were stored under refrigeration and analyzed after 0, 3, and 6 days of storage. These analyses at different times showed important changes in the volatile profile of the evaluated samples. The ketones 3-hydroxy-2-butanone and 2,3-butanedione, and the alcohol 3-methyl-1-butanol were the most representative compounds generated during the meat storage. In general, compounds associated with a butter off-flavor were detected during the storage of raw ground beef.

  6. Headspace solid-phase microextraction and gas chromatographic analysis of low-molecular-weight sulfur volatiles with pulsed flame photometric detection and quantification by a stable isotope dilution assay.

    PubMed

    Ullrich, Sebastian; Neef, Sylvia K; Schmarr, Hans-Georg

    2018-02-01

    Low-molecular-weight volatile sulfur compounds such as thiols, sulfides, disulfides as well as thioacetates cause a sulfidic off-flavor in wines even at low concentration levels. The proposed analytical method for quantification of these compounds in wine is based on headspace solid-phase microextraction, followed by gas chromatographic analysis with sulfur-specific detection using a pulsed flame photometric detector. Robust quantification was achieved via a stable isotope dilution assay using commercial and synthesized deuterated isotopic standards. The necessary chromatographic separation of analytes and isotopic standards benefits from the inverse isotope effect realized on an apolar polydimethylsiloxane stationary phase of increased film thickness. Interferences with sulfur-specific detection in wine caused by sulfur dioxide were minimized by addition of propanal. The method provides adequate validation data, with good repeatability and limits of detection and quantification. It suits the requirements of wine quality management, allowing the control of oenological treatments to counteract an eventual formation of excessively high concentration of such malodorous compounds. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Classification of bacteria by simultaneous methylation-solid phase microextraction and gas chromatography/mass spectrometry analysis of fatty acid methyl esters.

    PubMed

    Lu, Yao; Harrington, Peter B

    2010-08-01

    Direct methylation and solid-phase microextraction (SPME) were used as a sample preparation technique for classification of bacteria based on fatty acid methyl ester (FAME) profiles. Methanolic tetramethylammonium hydroxide was applied as a dual-function reagent to saponify and derivatize whole-cell bacterial fatty acids into FAMEs in one step, and SPME was used to extract the bacterial FAMEs from the headspace. Compared with traditional alkaline saponification and sample preparation using liquid-liquid extraction, the method presented in this work avoids using comparatively large amounts of inorganic and organic solvents and greatly decreases the sample preparation time as well. Characteristic gas chromatography/mass spectrometry (GC/MS) of FAME profiles was achieved for six bacterial species. The difference between Gram-positive and Gram-negative bacteria was clearly visualized with the application of principal component analysis of the GC/MS data of bacterial FAMEs. A cross-validation study using ten bootstrap Latin partitions and the fuzzy rule building expert system demonstrated 87 +/- 3% correct classification efficiency.

  8. Rapid screening of selective serotonin re-uptake inhibitors in urine samples using solid-phase microextraction gas chromatography-mass spectrometry.

    PubMed

    Salgado-Petinal, Carmen; Lamas, J Pablo; Garcia-Jares, Carmen; Llompart, Maria; Cela, Rafael

    2005-07-01

    In this paper a solid-phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS) method is proposed for a rapid analysis of some frequently prescribed selective serotonin re-uptake inhibitors (SSRI)-venlafaxine, fluvoxamine, mirtazapine, fluoxetine, citalopram, and sertraline-in urine samples. The SPME-based method enables simultaneous determination of the target SSRI after simple in-situ derivatization of some of the target compounds. Calibration curves in water and in urine were validated and statistically compared. This revealed the absence of matrix effect and, in consequence, the possibility of quantifying SSRI in urine samples by external water calibration. Intra-day and inter-day precision was satisfactory for all the target compounds (relative standard deviation, RSD, <14%) and the detection limits achieved were <0.4 ng mL(-1) urine. The time required for the SPME step and for GC analysis (30 min each) enables high throughput. The method was applied to real urine samples from different patients being treated with some of these pharmaceuticals. Some SSRI metabolites were also detected and tentatively identified.

  9. Speciation of butyltin compounds in marine sediments with headspace solid phase microextraction and gas chromatography mass spectrometry.

    PubMed

    Cardellicchio, N; Giandomenico, S; Decataldo, A; Di Leo, A

    2001-03-01

    A method for the determination of organotin compounds (monobutyl = MBT, dibutyl = DBT, and tributyltin = TBT) in marine sediments by headspace Solid Phase Microextraction (SPME) has been developed. The analytical procedure involved 1) extraction of TBT, DBT and MBT from sediments with HCl and methanol mixture, 2) in situ derivatization with sodium tetraethylborate and 3) headspace SPME extraction using a fiber coated with poly(dimethylsiloxane). The derivatized organotin compounds were desorbed into the splitless injector and simultaneously analyzed by gas chromatography - mass spectrometry. The analytical method was optimized with respect to derivatization reaction and extraction conditions. The detection limits obtained for MBT, DBT and TBT ranged from 730 to 969 pg/g as Sn dry weight. Linear calibration curves were obtained for all analytes in the range of 30-1000 ng/L as Sn. Analysis of a standard reference sediment (CRM 462) demonstrates the suitability of this method for the determination of butyltin compounds in marine sediments. The application to the determination of TBT, DBT and MBT in a coastal marine sediment is shown.

  10. Solid-phase microextraction of phthalate esters by a new coating based on a thermally stable polypyrrole/graphene oxide composite.

    PubMed

    Jafari, Mostafa; Ebrahimzadeh, Homeira; Banitaba, Mohammad Hossein; Davarani, Saied Saeed Hosseiny

    2014-11-01

    A novel polypyrole/graphene oxide coating was made by the electrochemical polymerization of pyrrole in the presence of sodium dodecyl sulfate and graphene oxide on a platinum wire. The prepared fiber has shown a good thermal stability up to 300°C. The fiber was applied to the direct solid-phase microextraction and gas chromatographic analysis of four phthalate esters. The effect of four parameters on gas chromatography peak area including extraction temperature, extraction time, injection temperature, and ionic strength were investigated. Under the optimized conditions, the detection limits were between 0.042 and 0.26 μg/L. The intraday and interday relative standard deviations obtained at 55 μg/L, using a single fiber, were 8.2-16% and 17.3-25.6%, respectively. The method was successfully applied to the analysis of phthalate esters in two real samples of boiling water in cheap disposable clear plastic drinking cups showing recoveries from 83 to 120%. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Enrichment and determination of octylphenol and nonylphenol in environmental water samples by solid-phase microextraction with carboxylated carbon nano-spheres coating prior to gas chromatography-mass spectrometry.

    PubMed

    Gong, Sheng-Xiang; Wang, Xia; Li, Lei; Wang, Ming-Lin; Zhao, Ru-Song

    2015-11-01

    In this paper, a novel and simple method for the sensitive determination of endocrine disrupter compounds octylphenol (OP) and nonylphenol (NP) in environmental water samples has been developed using solid-phase microextraction (SPME) coupled with gas chromatography-mass spectrometry. Carboxylated carbon nano-spheres (CNSs-COOH) are used as a novel SPME coating via physical adhesion. The CNSs-COOH fiber possessed higher adsorption efficiency than 100 μm polydimethysiloxane (PDMS) fiber and was similar to 85 μm polyacrylate (PA) fiber for the two analytes. Important parameters, such as extraction time, pH, agitation speed, ionic strength, and desorption temperature and time, were investigated and optimized in detail. Under the optimal parameters, the developed method achieved low limits of detection of 0.13~0.14 ng·L(-1) and a wide linear range of 1~1000 ng·(-1) for OP and NP. The novel method was validated with several real environmental water samples, and satisfactory results were obtained.

  12. Speciation analysis of organotin compounds in human urine by headspace solid-phase micro-extraction and gas chromatography with pulsed flame photometric detection.

    PubMed

    Valenzuela, Aníbal; Lespes, Gaëtane; Quiroz, Waldo; Aguilar, Luis F; Bravo, Manuel A

    2014-07-01

    A new headspace solid-phase micro-extraction (HS-SPME) method followed by gas chromatography with pulsed flame photometric detection (GC-PFPD) analysis has been developed for the simultaneous determination of 11 organotin compounds, including methyl-, butyl-, phenyl- and octyltin derivates, in human urine. The methodology has been validated by the analysis of urine samples fortified with all analytes at different concentration levels, and recovery rates above 87% and relative precisions between 2% and 7% were obtained. Additionally, an experimental-design approach has been used to model the storage stability of organotin compounds in human urine, demonstrating that organotins are highly degraded in this medium, although their stability is satisfactory during the first 4 days of storage at 4 °C and pH=4. Finally, this methodology was applied to urine samples collected from harbor workers exposed to antifouling paints; methyl- and butyltins were detected, confirming human exposure in this type of work environment. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Zero valent Fe-reduced graphene oxide quantum dots as a novel magnetic dispersive solid phase microextraction sorbent for extraction of organophosphorus pesticides in real water and fruit juice samples prior to analysis by gas chromatography-mass spectrometry.

    PubMed

    Akbarzade, Samaneh; Chamsaz, Mahmoud; Rounaghi, Gholam Hossein; Ghorbani, Mahdi

    2018-01-01

    A selective and sensitive magnetic dispersive solid-phase microextraction (MDSPME) coupled with gas chromatography-mass spectrometry was developed for extraction and determination of organophosphorus pesticides (Sevin, Fenitrothion, Malathion, Parathion, and Diazinon) in fruit juice and real water samples. Zero valent Fe-reduced graphene oxide quantum dots (rGOQDs@ Fe) as a new and effective sorbent were prepared and applied for extraction of organophosphorus pesticides using MDSPME method. In order to study the performance of this new sorbent, the ability of rGOQDs@ Fe was compared with graphene oxide and magnetic graphene oxide nanocomposite by recovery experiments of the organophosphorus pesticides. Several affecting parameters in the microextraction procedure, including pH of donor phase, donor phase volume, stirring rate, extraction time, and desorption conditions such as the type and volume of solvents and desorption time were thoroughly investigated and optimized. Under the optimal conditions, the method showed a wide linear dynamic range with R-square between 0.9959 and 0.9991. The limit of detections, the intraday and interday relative standard deviations (n = 5) were less than 0.07 ngmL -1 , 4.7, and 8.6%, respectively. The method was successfully applied for extraction and determination of organophosphorus pesticides in real water samples (well, river and tap water) and fruit juice samples (apple and grape juice). The obtained relative recoveries were in the range of 82.9%-113.2% with RSD percentages of less than 5.8% for all the real samples.

  14. Method and apparatus for optimized sampling of volatilizable target substances

    DOEpatents

    Lindgren, Eric R.; Phelan, James M.

    2002-01-01

    An apparatus for capturing, from gases such as soil gas, target analytes. Target analytes may include emanations from explosive materials or from residues of explosive materials. The apparatus employs principles of sorption common to solid phase microextraction, and is best used in conjunction with analysis means such as a gas chromatograph. To sorb target analytes, the apparatus functions using various sorptive structures to capture target analyte. Depending upon the embodiment, those structures may include 1) a conventional solid-phase microextraction (SPME) fiber, 2) a SPME fiber suspended in a capillary tube (with means provided for moving gases through the capillary tube so that the gases come into close proximity to the suspended fiber), and 3) a capillary tube including an interior surface on which sorptive material (similar to that on the surface of a SPME fiber) is supported (along with means for moving gases through the capillary tube so that the gases come into close proximity to the sorptive material). In one disclosed embodiment, at least one such sorptive structure is associated with an enclosure including an opening in communication with the surface of a soil region potentially contaminated with buried explosive material such as unexploded ordnance. Emanations from explosive materials can pass into and accumulate in the enclosure where they are sorbed by the sorptive structures. Also disclosed is the use of heating means such as microwave horns to drive target analytes into the soil gas from solid and liquid phase components of the soil.

  15. Development of a multi-preservative method based on solid-phase microextraction-gas chromatography-tandem mass spectrometry for cosmetic analysis.

    PubMed

    Alvarez-Rivera, Gerardo; Vila, Marlene; Lores, Marta; Garcia-Jares, Carmen; Llompart, Maria

    2014-04-25

    A simple methodology based on solid-phase microextraction (SPME) followed by gas chromatography-tandem mass spectrometry (GC-MS/MS) has been developed for the simultaneous analysis of different classes of preservatives including benzoates, bronidox, 2-phenoxyethanol, parabens, BHA, BHT and triclosan in cosmetic products. In situ acetylation and subsequent organic modifier addition have been successfully implemented in the SPME process as an effective extractive strategy for matrix effect compensation and chromatographic performance improvement. Main factors affecting SPME procedure such as fiber coating, sampling mode, extraction temperature and salt addition (NaCl) were evaluated by means of a 3×2(3-1) factorial experimental design. The optimal experimental conditions were established as follows: direct solid-phase microextraction (SPME) at 40°C and addition of NaCl (20%, w/v), using a DVB/CAR/PDMS fiber coating. Due to the complexity of the studied matrices, method performance was evaluated in a representative variety of both rinse-off and leave-on samples, demonstrating to have a broad linear range (R(2)>0.9964). In general, quantitative recoveries (>85% in most cases) and satisfactory precision (RSD<13% for most of compounds) were obtained, with limits of detection (LODs) well below the maximum authorized concentrations established by the European legislation. One of the most important achievements of this work was the use of external calibration with cosmetic-matched standards to accurately quantify the target analytes. The validated methodology was successfully applied to the analysis of different types of cosmetic formulations including body milks, moisturizing creams, deodorants, sunscreen, bath gel, dental cream and make-up products amongst others, demonstrating to be a reliable multi-preservative methododology for routine control. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Determination of acrylamide in brewed coffee and coffee powder using polymeric ionic liquid-based sorbent coatings in solid-phase microextraction coupled to gas chromatography-mass spectrometry.

    PubMed

    Cagliero, Cecilia; Ho, Tien D; Zhang, Cheng; Bicchi, Carlo; Anderson, Jared L

    2016-06-03

    This study describes a simple and rapid sampling method employing a polymeric ionic liquid (PIL) sorbent coating in direct immersion solid-phase microextraction (SPME) for the trace-level analysis of acrylamide in brewed coffee and coffee powder. The crosslinked PIL sorbent coating demonstrated superior sensitivity in the extraction of acrylamide compared to all commercially available SPME coatings. A spin coating method was developed to evenly distribute the PIL coating on the SPME support and reproducibly produce fibers with a large film thickness. Ninhydrin was employed as a quenching reagent during extraction to inhibit the production of interfering acrylamide. The PIL fiber produced a limit of quantitation for acrylamide of 10μgL(-1) and achieved comparable results to the ISO method in the analysis of six coffee powder samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Solid phase microextraction device using aerogel

    DOEpatents

    Miller, Fred S.; Andresen, Brian D.

    2005-06-14

    A sample collection substrate of aerogel and/or xerogel materials bound to a support structure is used as a solid phase microextraction (SPME) device. The xerogels and aerogels may be organic or inorganic and doped with metals or other compounds to target specific chemical analytes. The support structure is typically formed of a glass fiber or a metal wire (stainless steel or kovar). The devices are made by applying gel solution to the support structures and drying the solution to form aerogel or xerogel. Aerogel particles may be attached to the wet layer before drying to increase sample collection surface area. These devices are robust, stable in fields of high radiation, and highly effective at collecting gas and liquid samples while maintaining superior mechanical and thermal stability during routine use. Aerogel SPME devices are advantageous for use in GC/MS analyses due to their lack of interfering background and tolerance of GC thermal cycling.

  18. Method for preparing a solid phase microextraction device using aerogel

    DOEpatents

    Miller, Fred S [Bethel Island, CA; Andresen, Brian D [Livermore, CA

    2006-10-24

    A sample collection substrate of aerogel and/or xerogel materials bound to a support structure is used as a solid phase microextraction (SPME) device. The xerogels and aerogels may be organic or inorganic and doped with metals or other compounds to target specific chemical analytes. The support structure is typically formed of a glass fiber or a metal wire (stainless steel or kovar). The devices are made by applying gel solution to the support structures and drying the solution to form aerogel or xerogel. Aerogel particles may be attached to the wet layer before drying to increase sample collection surface area. These devices are robust, stable in fields of high radiation, and highly effective at collecting gas and liquid samples while maintaining superior mechanical and thermal stability during routine use. Aerogel SPME devices are advantageous for use in GC/MS analyses due to their lack of interfering background and tolerance of GC thermal cycling.

  19. Characterization of aroma compounds in apple cider using solvent-assisted flavor evaporation and headspace solid-phase microextraction.

    PubMed

    Xu, Yan; Fan, Wenlai; Qian, Michael C

    2007-04-18

    The aroma-active compounds in two apple ciders were identified using gas chromatography-olfactometry (GC-O) and GC-mass spectrometry (MS) techniques. The volatile compounds were extracted using solvent-assisted flavor evaporation (SAFE) and headspace solid-phase microextraction (HS-SPME). On the basis of odor intensity, the most important aroma compounds in the two apple cider samples were 2-phenylethanol, butanoic acid, octanoic acid, 2-methylbutanoic acid, 2-phenylethyl acetate, ethyl 2-methylbutanoate, ethyl butanoate, ethyl hexanoate, 4-ethylguaiacol, eugenol, and 4-vinylphenol. Sulfur-containing compounds, terpene derivatives, and lactones were also detected in ciders. Although most of the aroma compounds were common in both ciders, the aroma intensities were different. Comparison of extraction techniques showed that the SAFE technique had a higher recovery for acids and hydroxy-containing compounds, whereas the HS-SPME technique had a higher recovery for esters and highly volatile compounds.

  20. Solid phase microextraction applied to the analysis of organophosphorus insecticides in fruits.

    PubMed

    Fytianos, K; Raikos, N; Theodoridis, G; Velinova, Z; Tsoukali, H

    2006-12-01

    Trace amounts of organophosphorus pesticides (OPs) were determined in various fruits by headspace solid phase microextraction (HS-SPME) and gas chromatography-nitrogen phosphorous detection (GC-NPD). Sampling from the headspace enhanced method selectivity, whereas at the same time improved fiber life time and method sensitivity. Diazinon, parathion, methyl parathion, malathion and fenithrothion were determined in various fruits: more than 150 samples of 21 types of fruits were studied. SPME-GC-NPD provided a useful and very efficient analytical tool: method linearity ranged from 1.2 to 700 ng/ml. Limits of detection (LODs) and quantitation (LOQs) ranged from 0.03 to 3 ng/ml and 0.12 to 10 ng/ml respectively, values well below the residue limits set by the EU. Less than 2% of the samples were found positive containing amounts higher than the EU limits. The effect of fruit peeling and washing was also investigated.

  1. Headspace solid-phase microextraction (HS-SPME) and liquid-liquid extraction (LLE): comparison of the performance in classification of ecstasy tablets. Part 2.

    PubMed

    Bonadio, Federica; Margot, Pierre; Delémont, Olivier; Esseiva, Pierre

    2008-11-20

    Headspace solid-phase microextraction (HS-SPME) is assessed as an alternative to liquid-liquid extraction (LLE) currently used for 3,4-methylenedioxymethampethamine (MDMA) profiling. Both methods were compared evaluating their performance in discriminating and classifying samples. For this purpose 62 different seizures were analysed using both extraction techniques followed by gas chromatography-mass spectroscopy (GC-MS). A previously validated method provided data for HS-SPME, whereas LLE data were collected applying a harmonized methodology developed and used in the European project CHAMP. After suitable pre-treatment, similarities between sample pairs were studied using the Pearson correlation. Both methods enable to distinguish between samples coming from the same pre-tabletting batches and samples coming from different pre-tabletting batches. This finding emphasizes the use of HS-SPME as an effective alternative to LLE, with additional advantages such as sample preparation and a solvent-free process.

  2. Evaluation of needle trap micro-extraction and solid-phase micro-extraction: Obtaining comprehensive information on volatile emissions from in vitro cultures.

    PubMed

    Oertel, Peter; Bergmann, Andreas; Fischer, Sina; Trefz, Phillip; Küntzel, Anne; Reinhold, Petra; Köhler, Heike; Schubert, Jochen K; Miekisch, Wolfram

    2018-05-14

    Volatile organic compounds (VOCs) emitted from in vitro cultures may reveal information on species and metabolism. Owing to low nmol L -1 concentration ranges, pre-concentration techniques are required for gas chromatography-mass spectrometry (GC-MS) based analyses. This study was intended to compare the efficiency of established micro-extraction techniques - solid-phase micro-extraction (SPME) and needle-trap micro-extraction (NTME) - for the analysis of complex VOC patterns. For SPME, a 75 μm Carboxen®/polydimethylsiloxane fiber was used. The NTME needle was packed with divinylbenzene, Carbopack X and Carboxen 1000. The headspace was sampled bi-directionally. Seventy-two VOCs were calibrated by reference standard mixtures in the range of 0.041-62.24 nmol L -1 by means of GC-MS. Both pre-concentration methods were applied to profile VOCs from cultures of Mycobacterium avium ssp. paratuberculosis. Limits of detection ranged from 0.004 to 3.93 nmol L -1 (median = 0.030 nmol L -1 ) for NTME and from 0.001 to 5.684 nmol L -1 (median = 0.043 nmol L -1 ) for SPME. NTME showed advantages in assessing polar compounds such as alcohols. SPME showed advantages in reproducibility but disadvantages in sensitivity for N-containing compounds. Micro-extraction techniques such as SPME and NTME are well suited for trace VOC profiling over cultures if the limitations of each technique is taken into account. Copyright © 2018 John Wiley & Sons, Ltd.

  3. Determination of some aldehydes by using solid-phase microextraction and high-performance liquid chromatography with UV detection.

    PubMed

    Kumar, Ashwini; Singh, Baldev; Malik, Ashok Kumar; Tiwary, Dhananjay K

    2007-01-01

    A new approach has been developed for the extraction and determination of aldehydes such as veratraldehyde, m-nitrobenzaldehyde, cinnamaldehyde, benzaldehyde, and p-chlorobenzaldehyde by using solid-phase microextraction (SPME) and high-performance liquid chromatography with UV detection (HPLC/UV). The method involves adsorption of the aldehydes on polydimethylsiloxane/divinylbenzene-coated fiber, followed by desorption in the desorption chamber of the SPME-HPLC interface, using acetonitrile-water (70 + 30) as the mobile phase; UV detection was at 254 nm. A good separation of 5 aldehydes was obtained on a C18 column. The detection limits of veratraldehyde, m-nitrobenzaldehyde, cinnamaldehyde, benzaldehyde, and p-chlorobenzaldehyde are 25, 41, 13, 12, and 11 pg/mL, respectively, which are about 100 times better than the detection limits for other SPME methods using gas chromatography. The proposed method was validated by determining benzaldehyde in bitter almonds and cinnamaldehyde in cinnamon bark. The recoveries of the 5 analytes were determined by analysis of spiked drinking water.

  4. Headspace analysis of polar organic compounds in biological matrixes using solid phase microextraction (SPME)

    USDA-ARS?s Scientific Manuscript database

    Analysis of biological fluids and waste material is difficult and tedious given the sample matrix. A rapid automated method for the determination of volatile fatty acids and phenolic and indole compounds was developed using a multipurpose sampler (MPS) with solid phase microextraction (SPME) and GC-...

  5. Identification of unwanted photoproducts of cosmetic preservatives in personal care products under ultraviolet-light using solid-phase microextraction and micro-matrix solid-phase dispersion.

    PubMed

    Alvarez-Rivera, Gerardo; Llompart, Maria; Garcia-Jares, Carmen; Lores, Marta

    2015-04-17

    The photochemical transformation of widely used cosmetic preservatives including benzoates, parabens, BHA, BHT and triclosan has been investigated in this work applying an innovative double-approach strategy: identification of transformation products in aqueous photodegradation experiments (UV-light, 254nm), followed by targeted screening analysis of such photoproducts in UV-irradiated cosmetic samples. Solid-phase microextraction (SPME) was applied, using different fiber coatings, in order to widen the range of detectable photoproducts in water, whereas UV-irradiated personal care products (PCPs) containing the target preservatives were extracted by micro-matrix solid-phase dispersion (micro-MSPD). Both SPME and micro-MSPD-based methodologies were successfully optimized and validated. Degradation kinetics of parent species, and photoformation of their transformation by-products were monitored by gas chromatography coupled to mass spectrometry (GC-MS). Thirty nine photoproducts were detected in aqueous photodegradation experiments, being tentatively identified based on their mass spectra. Transformation pathways between structurally related by-products, consistent with their kinetic behavior were postulated. The photoformation of unexpected photoproducts such as 2- and 4-hydroxybenzophenones, and 2,8-dichlorodibenzo-p-dioxin in PCPs are reported in this work for the first time. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Measurement of gas-liquid partition coefficient and headspace concentration profiles of perfume materials by solid-phase microextraction and capillary gas chromatography-mass spectrometry

    PubMed

    Liu; Wene

    2000-09-01

    An empirical model describing the relationship between the partition coefficients (K) of perfume materials in the solid-phase microextraction (SPME) fiber stationary phase and the Linearly Temperature Programmed Retention Index (LTPRI) is obtained. This is established using a mixture of eleven selected fragrance materials spiked in mineral oil at different concentration levels to simulate liquid laundry detergent matrices. Headspace concentrations of the materials are measured using both static headspace and SPME-gas chromatography analysis. The empirical model is tested by measuring the K values for fourteen perfume materials experimentally. Three of the calculated K values are within 2-19% of the measured K value, and the other eleven calculated K values are within 22-59%. This range of deviation is understandable because a diverse mixture was used to cover most chemical functionalities in order to make the model generally applicable. Better prediction accuracy is expected when a model is established using a specific category of compounds, such as hydrocarbons or aromatics. The use of this method to estimate distribution constants of fragrance materials in liquid matrices is demonstrated. The headspace SPME using the established relationship between the gas-liquid partition coefficient and the LTPRI is applied to measure the headspace concentration of fragrances. It is demonstrated that this approach can be used to monitor the headspace perfume profiles over consumer laundry and cleaning products. This method can provide high sample throughput, reproducibility, simplicity, and accuracy for many applications for screening major fragrance materials over consumer products. The approach demonstrated here can be used to translate headspace SPME results into true static headspace concentration profiles. This translation is critical for obtaining the gas-phase composition by correcting for the inherent differential partitioning of analytes into the fiber stationary phase.

  7. Potential semiochemicals in urine from free ranging wolverines (Gulo gulo Pallas, 1780)

    Treesearch

    William F. Wood; Jeffrey P. Copeland; Richard E. Yates; Iman K. Horsey; Lynne R. McGreevy

    2009-01-01

    Urine deposition has been observed as an important scent-marking behaviour among wolverines (Gulo gulo, Mustelinae, Mustelidae). Solid phase microextraction (SPME) of headspace volatiles of the urine from free ranging wolverines were examined by gas chromatography-mass spectrometry (GC-MS). Urine samples were collected directly from the bladder of live-trapped animals...

  8. SIMPLE METHOD FOR ESTIMATING POLYCHLORINATED BIPHENYL CONCENTRATIONS ON SOILS AND SEDIMENTS USING SUBCRITICAL WATER EXTRACTION COUPLED WITH SOLID-PHASE MICROEXTRACTION. (R825368)

    EPA Science Inventory

    A rapid method for estimating polychlorinated biphenyl (PCB) concentrations in contaminated soils and sediments has been developed by coupling static subcritical water extraction with solid-phase microextraction (SPME). Soil, water, and internal standards are placed in a seale...

  9. A sol-gel based solid phase microextraction fiber for the analysis of aliphatic alcohols in apple juices.

    PubMed

    Farhadi, Khalil; Maleki, Ramin; Tahmasebi, Raheleh

    2010-01-01

    A new fiber based on titania-chitin sol-gel coated on a silver wire for the headspace solid phase microextraction of aliphatic alcohols from apple juice samples was developed. The influences of fiber coating composition and microextraction conditions (extraction temperature, extraction time, and ionic strength of the sample matrix) on the fiber performance were investigated. Also, the influence of temperature and time on desorption of analytes from fiber were studied. Under the optimized conditions, a porous fiber with a high extraction capacity and good thermal stability (up to 250 degrees C) was obtained. The proposed headspace solid-phase microextraction-GC method was successfully used for the analysis of aliphatic alcohols in apple juice and concentrate samples. The recovery values were from 92.8 to 98.6%. The RSD (n=5) for all analytes were below 7.8%.

  10. Determination of organotin compounds by headspace solid-phase microextraction-gas chromatography-pulsed flame-photometric detection (HS-SPME-GC-PFPD).

    PubMed

    Bravo, Manuel; Lespes, Gaëtane; De Gregori, Ida; Pinochet, Hugo; Gautier, Martine Potin

    2005-12-01

    A method based on Headspace solid-phase microextraction (HS-SPME, with a 100 mum PDMS-fiber) in combination with gas-chromatography and pulsed flame-photometric detection (GC-PFPD) has been investigated for simultaneous determination of eight organotin compounds. Monobutyltin (MBT), dibutyltin (DBT), tributyltin (TBT), monophenyltin (MPhT), and the semi-volatile diphenyltin (DPhT), triphenyltin (TPhT), monooctyltin (MOcT), and dioctyltin (DOcT) were determined after derivatization with sodium tetraethylborate. The conditions used for the extraction and preconcentration step were optimised by experimental design methodology. Tripropyltin (TPrT) and diheptyltin (DHepT) were used as internal standards for quantification of volatile and semi-volatile organotin compounds, respectively. The analytical precision (RSD) for ten successive injections of a standard mixture containing all the organic tin compounds ranged between 2 and 11%. The limits of detection for all the organotin compounds were sub ng (Sn) L(-1) in water and close to ng (Sn) kg(-1) in sediments. The accuracy of the method was evaluated by analysis of two certified reference material (CRM) sediment samples. The HS-SPME-GC-PFPD was then applied to the analysis of three harbour sediment samples. The results showed that headspace SPME is an attractive tool for analysis of organotin compounds in solid environmental matrices.

  11. Simultaneous determination of cyanogen chloride and cyanogen bromide in treated water at sub-microg/L levels by a new solid-phase microextraction-gas chromatographic-electron-capture detection method.

    PubMed

    Cancho, B; Ventur, F; Galceran, M

    2000-11-03

    A headspace solid-phase microextraction (HS-SPME) procedure has been developed and applied for the determination of cyanogen halides in treated water samples at microg/L concentrations. Several SPME coatings were tested, the divinylbenzene-Carboxen-polydimethylsiloxane fiber being the most appropriate coating. GC-electron-capture detection was used for separation and quantitation. Experimental parameters such as sample volume, addition of a salt, extraction time and desorption conditions were studied. The optimized method has an acceptable linearity, good precision, with RSD values <10% for both compounds, and it is sufficiently sensitive to detect ng/L levels. HS-SPME was compared with liquid-liquid microextraction (US Environmental Protection Agency Method 551.1) for the analysis of spiked ultrapure and granular activated carbon filtered water samples. There was good agreement between the results from both methods. Finally, the optimized procedure was applied to determine both compounds at the Barcelona water treatment plant (N.E. Spain). Cyanogen chloride in treated water was <1.0 microg/L and cyanogen bromide ranged from 3.2 to 6.4 microg/L.

  12. Porous organic polymers with different pore structures for sensitive solid-phase microextraction of environmental organic pollutants.

    PubMed

    Huang, Zhoubing; Liu, Shuqin; Xu, Jianqiao; Yin, Li; Zheng, Juan; Zhou, Ningbo; Ouyang, Gangfeng

    2017-10-09

    Adsorption capacity is the major sensitivity-limited factor in solid-phase microextraction. Due to its light-weight properties, large specific surface area and high porosity, especially tunable pore structures, the utilization of porous organic polymers as solid-phase microextraction adsorbents has attracting researchers' attentions. However, these works mostly concentrated on the utilization of specific porous organic polymers for preparing high-performance solid-phase microextraction coatings. The relationship between pore structures and adsorption performance of the porous organic polymers still remain unclear. Herein, three porous organic polymers with similar properties but different pore distributions were prepared by condensation polymerization reaction of phloroglucinol and terephthalaldehyde, which were fabricated as solid-phase microextraction coatings subsequently. The adsorption capacity of the porous organic polymers-coated fibers were evaluated by using benzene and its derivatives (i.e.,benzene, toluene, ethylbenzene and m-xylene) and polycyclic aromatic hydrocarbons as the target analytes. The results showed that the different adsorption performance of these porous organic polymers was mainly caused by their different pore volumes instead of their surface areas or pore sizes. Finally, the proposed method by using the mesoporous organic polymer coating was successfully applied to the determination of benzene and its derivatives in environmental water samples. As for analytical performance, high pre-concentration factors (74-2984), satisfactory relative recoveries (94.5 ± 18.5-116.9 ± 12.5%), intraday precision (2.44-5.34%), inter-day precision (4.62-7.02%), low limit of detections (LODs, 0.10-0.29 ng L -1 ) and limit of quantifications (LOQs, 0.33-0.96 ng L -1 ) were achieved under the optimal conditions. This study provides an important idea in the rational design of porous organic polymers for solid-phase microextraction or other adsorption applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Variables controlling the recovery of ignitable liquid residues from simulated fire debris samples using solid-phase microextraction/gas chromatography

    NASA Astrophysics Data System (ADS)

    Furton, Kenneth G.; Almirall, Jose R.; Wang, Jing

    1999-02-01

    In this paper, we present data comparing a variety of different conditions for extracting ignitable liquid residues from simulated fire debris samples in order to optimize the conditions for using Solid Phase Microextraction. A simulated accelerant mixture containing 30 components, including those from light petroleum distillates, medium petroleum distillates and heavy petroleum distillates were used to study the important variables controlling Solid Phase Microextraction (SPME) recoveries. SPME is an inexpensive, rapid and sensitive method for the analysis of volatile residues from the headspace over solid debris samples in a container or directly from aqueous samples followed by GC. The relative effects of controllable variables, including fiber chemistry, adsorption and desorption temperature, extraction time, and desorption time, have been optimized. The addition of water and ethanol to simulated debris samples in a can was shown to increase the sensitivity when using headspace SPME extraction. The relative enhancement of sensitivity has been compared as a function of the hydrocarbon chain length, sample temperature, time, and added ethanol concentrations. The technique has also been optimized to the extraction of accelerants directly from water added to the fire debris samples. The optimum adsorption time for the low molecular weight components was found to be approximately 25 minutes. The high molecular weight components were found at a higher concentration the longer the fiber was exposed to the headspace (up to 1 hr). The higher molecular weight components were also found in higher concentrations in the headspace when water and/or ethanol was added to the debris.

  14. Rapid separation of beryllium and lanthanide derivatives by capillary gas chromatography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harvey, Scott D.; Lucke, Richard B.; Douglas, Matt

    2012-09-04

    Previous studies describe derivatization of metal ions followed by analysis using gas chromatography, usually on packed columns. In many of these studies, stable and volatile derivatives were formed using fluorinated β-diketonate reagents. This paper extends previous work by investigating separations of the derivatives on small-diameter capillary gas chromatography columns and exploring on-fiber, solid-phase microextraction derivatization techniques for beryllium. The β-diketonate used for these studies was 1,1,1,2,2,6,6,7,7,7-decafluoro-3,5-heptanedione. Derivatization of lanthanides also required addition of a neutral donor, dibutyl sulfoxide, in addition to 1,1,1,2,2,6,6,7,7,7-decafluoro-3,5-heptanedione. Unoptimized separations on a 100-μm i.d. capillary column proved capable of rapid separations (within 15 min) of lanthanidemore » derivatives that are adjacent to one another in the periodic table. Full-scan mass spectra were obtained from derivatives containing 5 ng of each lanthanide. Studies also developed a simple on-fiber solid-phase microextraction derivatization of beryllium. Beryllium could be analyzed in the presence of other alkali earth elements (Ba(II) and Sr(II)) without interference. Finally, extension of the general approach was demonstrated for several additional elements (i.e. Cu(II), Cr(III), and Ga(III)).« less

  15. Analysis of enantiomeric and non-enantiomeric monoterpenes in plant emissions using portable dynamic air sampling/solid-phase microextraction (PDAS-SPME) and chiral gas chromatography/mass spectrometry

    NASA Astrophysics Data System (ADS)

    Yassaa, Noureddine; Williams, Jonathan

    A portable dynamic air sampler (PDAS) using a porous polymer solid-phase microextraction (SPME) fibre has been validated for the determination of biogenic enantiomeric and non-enantiomeric monoterpenes in air. These compounds were adsorbed in the field, and then thermally desorbed at 250 °C in a gas chromatograph injector port connected via a β-cyclodextrin capillary separating column to a mass spectrometer. The optimized method has been applied for investigating the emissions of enantiomeric monoterpenes from Pseudotsuga menziesii (Douglas-fir), Rosmarinus officinalis (Rosemary) and Lavandula lanata (Lavender) which were selected as representative of coniferous trees and aromatic plants, respectively. The enantiomers of α-pinene, sabinene, camphene, δ-3-carene, β-pinene, limonene, β-phellandrene, 4-carene and camphor were successfully determined in the emissions from the three plants. While Douglas-fir showed a strong predominance toward (-)-enantiomers, Rosemary and Lavender demonstrated a large variation in enantiomeric distribution of monoterpenes. The simplicity, rapidity and sensitivity of dynamic sampling with porous polymer coated SPME fibres coupled to chiral capillary gas chromatography/mass spectrometry (GC/MS) makes this method potentially useful for in-field investigations of atmosphere-biosphere interactions and studies of optically explicit atmospheric chemistry.

  16. Evaluation of solid-phase microextraction desorption parameters for fast GC analysis of cocaine in coca leaves.

    PubMed

    Ilias, Yara; Bieri, Stefan; Christen, Philippe; Veuthey, Jean-Luc

    2006-08-01

    By its simplicity and rapidity, solid-phase microextraction (SPME) appears as an interesting alternative for sample introduction in fast gas chromatography (fast GC). This combination depends on numerous parameters affecting the desorption step (i.e., the release of compounds from the SPME fiber coating to the GC column). In this study, different liner diameters, injection temperatures, and gas flow rates are evaluated to accelerate the thermal desorption process in the injection port. This process is followed with real-time direct coupling a split/splitless injector to a mass spectrometer by means of a short capillary. It is shown that an effective, quantitative, and rapid transfer of cocaine (COC) and cocaethylene (CE) is performed with a 0.75-mm i.d. liner, at 280 degrees C and 4 mL/min gas flow rate. The 7-microm polydimethylsiloxane (PDMS) coating is selected for combination with fast GC because the 100-microm PDMS fiber presents some limitations caused by fiber bleeding. Finally, the developed SPME-fast GC method is applied to perform in less than 5 min, the quantitation of COC extracted from coca leaves by focused microwave-assisted extraction. An amount of 7.6 +/- 0.5 mg of COC per gram of dry mass is found, which is in good agreement with previously published results.

  17. Characterization and semiquantitative analysis of volatiles in seedless watermelon varieties using solid-phase microextraction.

    PubMed

    Beaulieu, John C; Lea, Jeanne M

    2006-10-04

    Seedless triploid watermelons have increased in popularity since the early 1990s, and the demand for seedless fruit is on the rise. Sweetness and sugars are crucial breeding focuses for fruit quality. Volatiles also play an important role; yet, we found no literature for seedless varieties and no reports using solid-phase microextraction (SPME) in watermelon. The objective of this experiment was to identify volatile and semivolatile compounds in five seedless watermelon varieties using carboxen divinylbenzene polydimethylsiloxane solid-phase microextraction (SPME) with gas chromatography-mass spectrometry (GC-MS). Fully ripe watermelon was squeezed through miracloth to produce rapid juice extracts for immediate headspace SPME GC-MS. Aldehydes, alcohols, ketones, and one furan (2-pentyl furan, a lipid oxidation product) were recovered. On the basis of total ion count peak area, the most abundant compounds in five varieties were 3-nonen-1-ol/(E,Z)-2,6-nonadienal (16.5-28.2%), (E)-2-nonenal (10.6-22.5%), and (Z)-6-nonenal (2.0-11.3%). Hexanal was most abundant (37.7%) in one variety (Petite Perfection) [corrected] The most abundant ketone was 6-methyl-5-hepten-2-one (2.7-7.7%). Some sensory attributes reported for these compounds are melon, citrus, cucumber, orange, rose, floral, guava, violet, vegetable, green, grassy, herbaceous, pungent, fatty, sweet, and waxy. Identifying and relating these compounds to sensory attributes will allow for future monitoring of the critical flavor compounds in seedless watermelon after processing and throughout fresh-cut storage.

  18. PARTITION INFRARED METHOD FOR TOTAL GASOLINE RANGE ORGANICS IN WATER BASED ON SOLID PHASE MICROEXTRACTION. (R825343)

    EPA Science Inventory

    A new method is described for determining total gasoline-range organics
    (TGRO) in water that combines solid-phase microextraction (SPME) and infrared
    (IR) spectroscopy. In this method, the organic compounds are extracted from
    250-mL of water into a small square (3....

  19. SCREENING METHOD FOR NITROAROMATIC COMPOUNDS IN WATER BASED ON SOLID-PHASE MICROEXTRACTION AND INFRARED SPECTROSCOPY. (R825343)

    EPA Science Inventory

    A new method is described for determining nitroaromatic compounds in water
    that combines solid-phase microextraction (SPME) and infrared (IR) spectroscopy. In this method, the compounds are extracted from a 250-mL volume of water into a small square (3.2 cm ? 3.2 cm ? 61.2...

  20. HIGH LEVELS OF MONOAROMATIC COMPOUNDS LIMIT THE USE OF SOLID-PHASE MICROEXTRACTION OF METHYL TERTIARY BUTYL ETHER AND TERTIARY BUTYL ALCOHOL

    EPA Science Inventory

    Recently, two papers reported the use of solid-phase microextraction (SPME) with polydimethylsiloxane(PDMS)/Carboxen fibers to determine trace levels of methyl tertiary butyl ether (MTBE) and tertiary butyl alcohol (tBA) in water. Attempts were made to apply this technique to th...

  1. Molecularly imprinted-solid phase extraction combined with simultaneous derivatization and dispersive liquid-liquid microextraction for selective extraction and preconcentration of methamphetamine and ecstasy from urine samples followed by gas chromatography.

    PubMed

    Djozan, Djavanshir; Farajzadeh, Mir Ali; Sorouraddin, Saeed Mohammad; Baheri, Tahmineh

    2012-07-27

    In this study, a developed technique was reported for extraction and pre-concentration of methamphetamine (MAMP) and 3,4-methylenedioxymethamphetamine (MDMA, ecstasy) from urine samples using molecularly imprinted-solid phase extraction (MISPE) along with simultaneous derivatization and dispersive liquid-liquid microextraction (DLLME). Molecularly imprinted microspheres as sorbent in solid phase extraction (SPE) procedure were synthesized using precipitation polymerization with MAMP as the template. Aqueous solution of the target analytes was passed through MAMP-MIP cartridge and the adsorbed analytes were then eluted with methanol. The collected eluate was mixed with butylchloroformate which served as the derivatization reagent as well as the extraction solvent. The mixture was immediately injected into deionized water. After centrifugation, 1 μL of the settled organic phase was injected into gas chromatography-flame ionization detection (GC-FID) or gas chromatography-mass spectrometry (GC-MS). Various experimental parameters affecting the performance of both of the steps (MISPE and DLLME) were thoroughly investigated. The calibration graphs were linear in the ranges of 10-1500 ng mL(-1) (MAMP) and 50-1500 ng mL(-1) (MDMA), and the detection limits (LODs) were 2 and 18 ng mL(-1), respectively. The relative standard deviations (%RSDs) obtained for six repeated experiments (100 ng mL(-1) of each drug) were 5.1% and 6.8% for MAMP and MDMA, respectively. The relative recoveries obtained for the analytes in human urine samples, spiked with different levels of each drug, were within the range of 80-88%. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Multivariate optimization of a headspace solid-phase microextraction method followed by gas chromatography with mass spectrometry for the determination of terpenes in Nicotiana langsdorffii.

    PubMed

    Ardini, Francisco; Carro, Marina Di; Abelmoschi, Maria Luisa; Grotti, Marco; Magi, Emanuele

    2014-07-01

    A simple and sensitive procedure based on headspace solid-phase microextraction and gas chromatography with mass spectrometry was developed for the determination of five terpenes (α-pinene, limonene, linalool, α-terpineol, and geraniol) in the leaves of Nicotiana langsdorffii. The microextraction conditions (extraction temperature, equilibration time, and extraction time) were optimized by means of a Doehlert design. The experimental design showed that, for α-pinene and limonene, a low temperature and a long extraction time were needed for optimal extraction, while linalool, α-terpineol, and geraniol required a high temperature and a long extraction time. The chosen compromise conditions were temperature 60°C, equilibration time 15 min and extraction time 50 min. The main analytical figures of the optimized method were evaluated; LODs ranged from 0.07 ng/g (α-pinene) to 8.0 ng/g (geraniol), while intraday and interday repeatability were in the range 10-17% and 9-13%, respectively. Finally, the procedure was applied to in vitro wild-type and transgenic specimens of N. langsdorffii subjected to abiotic stresses (chemical and heat stress). With the exception of geraniol (75-374 ng/g), low concentration levels of terpenes were measured (ng/g level or lower); some interesting variations in terpene concentration induced by abiotic stress were observed. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Multiple headspace-solid-phase microextraction: an application to quantification of mushroom volatiles.

    PubMed

    Costa, Rosaria; Tedone, Laura; De Grazia, Selenia; Dugo, Paola; Mondello, Luigi

    2013-04-03

    Multiple headspace-solid phase microextraction (MHS-SPME) followed by gas chromatography/mass spectrometry (GC-MS) and flame ionization detection (GC-FID) was applied to the identification and quantification of volatiles released by the mushroom Agaricus bisporus, also known as champignon. MHS-SPME allows to perform quantitative analysis of volatiles from solid matrices, free of matrix interferences. Samples analyzed were fresh mushrooms (chopped and homogenized) and mushroom-containing food dressings. 1-Octen-3-ol, 3-octanol, 3-octanone, 1-octen-3-one and benzaldehyde were common constituents of the samples analyzed. Method performance has been tested through the evaluation of limit of detection (LoD, range 0.033-0.078 ng), limit of quantification (LoQ, range 0.111-0.259 ng) and analyte recovery (92.3-108.5%). The results obtained showed quantitative differences among the samples, which can be attributed to critical factors, such as the degree of cell damage upon sample preparation, that are here discussed. Considerations on the mushrooms biochemistry and on the basic principles of MHS analysis are also presented. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Hapsite Gas Chromatography - Mass Spectrometry with Solid Phase Microextraction

    DTIC Science & Technology

    2005-07-18

    Polydimethylsiloxane /Divinylbenzene (PDMS/DVB) 65um/partially crosslinked*** Polar volatiles 60urn/ partially crosslinked General purpose (for HPLC ... Polydimethylsiloxane (PDMS). The HAPSITE with tri-bed concentrator achieved the lowest detection limits. The HAPSITE and the field portable GCUMS... Polydimethylsiloxane (PDMS). The HAPSITE with tri-bed concentrator achieved the lowest detection limits. The HAPSITE and the field portable GC/MS instrument coupled

  5. Optimization of a Solid-Phase Microextraction method for the Gas Chromatography-Mass Spectrometry analysis of blackberry (Rubus ulmifolius Schott) fruit volatiles.

    PubMed

    D'Agostino, M F; Sanz, J; Sanz, M L; Giuffrè, A M; Sicari, V; Soria, A C

    2015-07-01

    A Solid-Phase Microextraction method for the Gas Chromatography-Mass Spectrometry analysis of blackberry (Rubus sp.) volatiles has been fully optimized by means of a Box-Behnken experimental design. The optimized operating conditions (Carboxen/Polydimethylsiloxane fiber coating, 66°C, 20 min equilibrium time and 16 min extraction time) have been applied to the characterization for the first time of the volatile composition of Rubus ulmifolius Schott blackberries collected in Italy and Spain. A total of 74 volatiles of different functionality were identified; esters and aliphatic alcohols were the predominant classes in both sample types. Methylbutanal (2.02-25.70%), ethanol (9.84-68.21%), 2,3-butanedione (2.31-14.71%), trans-2-hexenal (0.49-17.49%), 3-hydroxy-2-butanone (0.08-7.39%), 1-hexanol (0.56-16.39%), 1-octanol (0.49-10.86%) and methylbutanoic acid (0.53-21.48%) were the major compounds in most blackberries analyzed. Stepwise multiple regression analysis of semiquantitative data showed that only two variables (ethyl decanoate and ethyl acetate) were necessary for a successful differentiation of blackberries according to their harvest location. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Solid-phase microextraction coupled to gas chromatography for the determination of 2,3-dimethyl-2,3-dinitrobutane as a marking agent for explosives.

    PubMed

    Li, Xiujuan; Zeng, Zhaorui; Zeng, Yi

    2007-06-15

    This paper investigates the detection of 2,3-dimethyl-2,3-dinitrobutane (DMNB), a marking agent in explosives, by gas chromatography (GC) with electron capture detection using solid-phase microextraction (SPME) as a sample preparation technique. The 25,27-dihydroxy-26,28-oxy (2',7'-dioxo-3',6'-diazaoctyl) oxy-p-tert-butylcalix[4]arene/hydroxy-terminated silicone oil coated fiber was highly sensitive to trap DMNB from ammonium nitrate matrix. The analysis was performed by extracting 2g of explosives for 30s at room temperature and then immediately introducing into the heated GC injector for 1min of thermal desorption. The method showed good linearity in the range from 0.01 to 1.0mug/g. The relative standard deviations for these extractions were <8%. The calculated limit of detection for DMNB (S/N=3) was 4.43x10(-4)mug/g, which illustrates that the proposed systems are suitable for explosive detection at trace level. This is the first report of an SPME-GC system shown to extract marking agent in explosives for subsequent detection in a simple, rapid, sensitive, and inexpensive manner.

  7. Influence of harvest maturity and fruit logistics on pineapple (Ananas comosus [L.] Merr.) volatiles assessed by headspace solid phase microextraction and gas chromatography-mass spectrometry (HS-SPME-GC/MS).

    PubMed

    Steingass, Christof B; Grauwet, Tara; Carle, Reinhold

    2014-05-01

    Profiling of volatiles from pineapple fruits was performed at four ripening stages using headspace solid-phase microextraction and gas chromatography-mass spectrometry (HS-SPME-GC/MS). In total, 142 volatiles were detected, of which 132 were identified. Multivariate data analysis was carried out to assess the effect of post-harvest storage on volatiles composition of green-ripe sea-freighted pineapple in comparison to air-freighted fruits harvested at full maturity. The latter fruits were characterised by volatiles described as potent odorants in pineapples, such as δ-octalactone, γ-lactones, 1-(E,Z)-3,5-undecatriene and 1,3,5,8-undecatetraene, as well as various methyl esters. In contrast, post-harvest storage of green-ripe sea-freighted fruits resulted in an increased formation of ethyl esters, acetates, acetoxy esters and alcohols, thus allowing the authentication of sea- and air-freighted pineapples, respectively. Particularly, compounds presumably derived from methyl-branched amino acid catabolism were identified in the fruits at later post-harvest stages. In addition, physicochemical traits were determined to characterise the fruit maturity stages. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. A fast and simple solid phase microextraction coupled with gas chromatography-triple quadrupole mass spectrometry method for the assay of urinary markers of glutaric acidemias.

    PubMed

    Naccarato, Attilio; Gionfriddo, Emanuela; Elliani, Rosangela; Sindona, Giovanni; Tagarelli, Antonio

    2014-10-30

    The analysis of characteristic urinary acidic markers such as glutaric, 3-hydroxyglutaric, 2-hydroxyglutaric, adipic, suberic, sebacic, ethylmalonic, 3-hydroxyisovaleric and isobutyric acid constitutes the recommended follow-up testing procedure for glutaric acidemia type 1 (GA-1) and type 2 (GA-2). The goal of the work herein presented is the development of a fast and simple method for the quantification of these biomarkers in human urine. The proposed analytical approach is based on the use of solid phase microextraction (SPME) combined with gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS) afterward a rapid derivatization of acidic moieties by propyl chloroformate, propanol and pyridine. Trueness and precision of the proposed protocol, tested at 5, 30 and 80mgl -1 , provided satisfactory values: recoveries were in the range between 72% and 116% and the relative standard deviations (RSD%) were between 0.9% and 18% (except for isobutyric acid at 5mgl -1 ). The LOD values achieved by the proposed method ranged between 1.0 and 473μgl -1 . Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Rapid Determination of Clenbuterol in Pork by Direct Immersion Solid-Phase Microextraction Coupled with Gas Chromatography-Mass Spectrometry.

    PubMed

    Ye, Diru; Wu, Susu; Xu, Jianqiao; Jiang, Ruifen; Zhu, Fang; Ouyang, Gangfeng

    2016-02-01

    Direct immersion solid-phase microextraction (DI-SPME) coupled with gas chromatography-mass spectrometry (GC-MS) was developed for rapid analysis of clenbuterol in pork for the first time. In this work, a low-cost homemade 44 µm polydimethylsiloxane (PDMS) SPME fiber was employed to extract clenbuterol in pork. After extraction, derivatization was performed by suspending the fiber in the headspace of the 2 mL sample vial saturated with a vapor of 100 µL hexamethyldisilazane. Lastly, the fiber was directly introduced to GC-MS for analysis. All parameters that influenced absorption (extraction time), derivatization (derivatization reagent, time and temperature) and desorption (desorption time) were optimized. Under optimized conditions, the method offered a wide linear range (10-1000 ng g(-1)) and a low detection limit (3.6 ng g(-1)). Finally, the method was successfully applied in the analysis of pork from the market, and recoveries of the method for spiked pork were 97.4-105.7%. Compared with the traditional solvent extraction method, the proposed method was much cheaper and fast. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Nanostructured copper-coated solid-phase microextraction fiber for gas chromatographic analysis of dibutyl phthalate and diethylhexyl phthalate environmental estrogens.

    PubMed

    Feng, Juanjuan; Sun, Min; Bu, Yanan; Luo, Chuannan

    2015-01-01

    A novel nanostructured copper-based solid-phase microextraction fiber was developed and applied for determining the two most common types of phthalate environmental estrogens (dibutyl phthalate and diethylhexyl phthalate) in aqueous samples, coupled to gas chromatography with flame ionization detection. The copper film was coated onto a stainless-steel wire via an electroless plating process, which involved a surface activation process to improve the surface properties of the fiber. Several parameters affecting extraction efficiency such as extraction time, extraction temperature, ionic strength, desorption temperature, and desorption time were optimized by a factor-by-factor procedure to obtain the highest extraction efficiency. The as-established method showed wide linear ranges (0.05-250 μg/L). Precision of single fiber repeatability was <7.0%, and fiber-to-fiber repeatability was <10%. Limits of detection were 0.01 μg/L. The proposed method exhibited better or comparable extraction performance compared with commercial and other lab-made fibers, and excellent thermal stability and durability. The proposed method was applied successfully for the determination of model analytes in plastic soaking water. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Solid phase microextraction and gas chromatography-mass spectrometry methods for residual solvent assessment in seized cocaine and heroin.

    PubMed

    Cabarcos, Pamela; Herbello-Hermelo, Paloma; Álvarez-Freire, Iván; Moreda-Piñeiro, Antonio; Tabernero, María Jesús; Bermejo, Ana María; Bermejo-Barrera, Pilar

    2016-09-01

    A simple sample pre-treatment method based on solid phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS) has been optimized and validated for the assessment of 15 residual solvents (2-propanol, 2-methylpentane, 3-methylpentane, acetone, ethyl acetate, benzene, hexane, methylcyclohexane, methylcyclopentane, m-xylene, propyl acetate, toluene, 1,2,4-trimethylbenzene, dichloromethane, and ethylbenzene) in seized illicit cocaine and heroin. DMSO and DMF as sample diluents were found to offer the best residual solvent transference to the head space for further adsorption onto the SPME fiber, and the developed method therefore showed high sensitivity and analytical recovery. Variables affecting SPME were fully evaluated by applying an experimental design approach. Best conditions were found when using an equilibration time of 5 min at 70 °C and headspace sampling of residual solvents at the same temperature for 15 min. Method validation, performed within the requirements of international guidelines, showed excellent sensitivity, as well as intra- and inter-day precision and accuracy. The proposed methodology was applied to 96 cocaine samples and 14 heroin samples seized in Galicia (northwestern Spain) within 2013 and 2014.

  12. Quantification of selected aroma-active compounds in strawberries by headspace solid-phase microextraction gas chromatography and correlation with sensory descriptive analysis.

    PubMed

    Jetti, R R; Yang, E; Kurnianta, A; Finn, C; Qian, M C

    2007-09-01

    Selected aroma-active compounds in strawberries were quantified using headspace solid-phase microextraction and gas chromatography. Ten strawberry cultivars grown in California and Oregon were studied. The standard curves were built in a synthetic matrix and quantification was achieved using multiple internal standards. Odor activity values (OAVs) of the aroma compounds were calculated to understand their contribution to the overall aroma. Although the concentrations of the aroma compounds varied depending on the cultivars, in general, ethyl butanoate, mesifurane, ethyl hexanoate, ethyl 3-methylbutanoate, hexyl acetate, and gamma-dodecalactone had the highest OAVs. Descriptive sensory analysis was performed by a trained panel of 10 members. A PCA plot was built to understand the aroma contribution of principal components. The chemical results were compared with sensory data. The OAV of esters correlated well with the floral, pineapple, and banana notes. The green notes did not correlate with the concentration or OAVs of aldehydes or C6 alcohols. It is assumed that the higher amounts of green, sulfur, musty, and waxy notes in some cultivars were due to the lack of fruity notes.

  13. Analysis of ammonium nitrate headspace by on-fiber solid phase microextraction derivatization with gas chromatography mass spectrometry.

    PubMed

    Lubrano, Adam L; Andrews, Benjamin; Hammond, Mark; Collins, Greg E; Rose-Pehrsson, Susan

    2016-01-15

    A novel analytical method has been developed for the quantitation of trace levels of ammonia in the headspace of ammonium nitrate (AN) using derivatized solid phase microextraction (SPME) fibers with gas chromatography mass spectrometry (GC-MS). Ammonia is difficult to detect via direct injection into a GC-MS because of its low molecular weight and extreme polarity. To circumvent this issue, ammonia was derivatized directly onto a SPME fiber by the reaction of butyl chloroformate coated fibers with the ammonia to form butyl carbamate. A derivatized externally sampled internal standard (dESIS) method based upon the reactivity of diethylamine with unreacted butyl chloroformate on the SPME fiber to form butyl diethylcarbamate was established for the reproducible quantification of ammonia concentration. Both of these compounds are easily detectable and separable via GC-MS. The optimized method was then used to quantitate the vapor concentration of ammonia in the headspace of two commonly used improvised explosive device (IED) materials, ammonium nitrate fuel oil (ANFO) and ammonium nitrate aluminum powder (Ammonal), as well as identify the presence of additional fuel components within the headspace. Published by Elsevier B.V.

  14. An efficient method for the simultaneous determination of furan, 2-methylfuran and 2-pentylfuran in fruit juices by headspace solid phase microextraction and gas chromatography-flame ionisation detector.

    PubMed

    Hu, Gaofei; Zhu, Yan; Hernandez, Marta; Koutchma, Tatiana; Shao, Suqin

    2016-02-01

    A headspace solid phase microextraction (HS-SPME) procedure followed by gas chromatography-flame ionisation detector (GC-FID) analysis was developed and validated for the simultaneous analysis of furan, 2-methylfuran and 2-pentylfuran from juice samples. Extraction at 32 °C for 20 min with stirring at 600 rpm and NaCl concentration 15% (W/V) was the optimal HS-SPME condition for all the three compounds by using a carboxen/polydimethylsiloxane fused silica fibre (75 μm). The extracted compounds were base line separated on a SPB-1 GC column within 12 min. The relative standard deviations of all analytes were less than 6.7%. The recovery rates were between 90.2% and 110.1%. The limits of detection and limits of quantification were 0.056-0.23 ng/mL and 0.14-0.76 ng/mL, respectively. The results showed that the developed method was sensitive, precise, accurate and robust for the determination of furan, 2-methylfuran and 2-pentylfuran in complex matrices without interferences from other components. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  15. Authentication of pineapple (Ananas comosus [L.] Merr.) fruit maturity stages by quantitative analysis of γ- and δ-lactones using headspace solid-phase microextraction and chirospecific gas chromatography-selected ion monitoring mass spectrometry (HS-SPME-GC-SIM-MS).

    PubMed

    Steingass, Christof B; Langen, Johannes; Carle, Reinhold; Schmarr, Hans-Georg

    2015-02-01

    Headspace solid phase microextraction and chirospecific gas chromatography-mass spectrometry in selected ion monitoring mode (HS-SPME-GC-SIM-MS) allowed quantitative determination of δ-lactones (δ-C8, δ-C10) and γ-lactones (γ-C6, γ-C8, γ-C10). A stable isotope dilution assay (SIDA) with d7-γ-decalactone as internal standard was used for quantitative analysis of pineapple lactones that was performed at three progressing post-harvest stages of fully ripe air-freighted and green-ripe sea-freighted fruits, covering the relevant shelf-life of the fruits. Fresh pineapples harvested at full maturity were characterised by γ-C6 of high enantiomeric purity remaining stable during the whole post-harvest period. In contrast, the enantiomeric purity of γ-C6 significantly decreased during post-harvest storage of sea-freighted pineapples. The biogenetical background and the potential of chirospecific analysis of lactones for authentication and quality evaluation of fresh pineapple fruits are discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Graphene oxide bonded fused-silica fiber for solid-phase microextraction-gas chromatography of polycyclic aromatic hydrocarbons in water.

    PubMed

    Xu, Lili; Feng, Juanjuan; Li, Jubai; Liu, Xia; Jiang, Shengxiang

    2012-01-01

    A novel chemically bonded graphene oxide/fused-silica fiber was prepared and applied in solid-phase microextraction of six polycyclic aromatic hydrocarbons from water samples coupled with gas chromatography. It exhibited high extraction efficiency and excellent stability. Effects of extraction time, extraction temperature, ionic strength, stirring rate and desorption conditions were investigated and optimized in our work. Detection limits to the six polycyclic aromatic hydrocarbons were less than 0.08 μg/L, and their calibration curves were all linear (R(2)≥0.9954) in the range from 0.05 to 200 μg/L. Single fiber repeatability and fiber-to-fiber reproducibility were less than 6.13 and 15.87%, respectively. This novel fiber was then utilized to analyze two real water samples from the Yellow River and local waterworks, and the recoveries of samples spiked at 1 and 10 μg/L ranged from 84.48 to 118.24%. Compared with other coating materials, this graphene oxide-coated fiber showed many advantages: wide linear range, low detection limit, and good stability in acid, alkali, organic solutions and at high temperature. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Determination of Sucrose in Honey with Derivatization/Solid-Phase Microextraction and Gas-Chromatography/Mass Spectrometry.

    PubMed

    Wang, Haijing; Geppert, Helmut; Fischer, Thomas; Wieprecht, Wolfgang; Möller, Detlev

    2015-10-01

    A new method for the determination of sucrose in honey with derivatization solid-phase microextraction and gas chromatography/mass spectrometry (D-SPME-GC/MS) was developed. The method incorporates a sample derivatization with acetic anhydride using N-methylimidazole as the catalyst and the subsequent enrichment of the analyte in a Polyacrylate-SPME fiber. Results show that 100 µL N-methylimidazole and 800 µL acetic anhydride were sufficient to complete the acetylation for sucrose in 100 µL aqueous sample at room temperature. For SPME, an enrichment time of 30 min was sufficient. SPME was performed by immersing the fiber into the solution with additional vibration. Then, the analyte was desorbed for 5 min at 280°C in the GC/MS injection port with splitless mode. The present method exhibits good linearity at a concentration range of 0.3-8% of sucrose in honey with excellent regression (R = 0.9993). The method has been successfully applied to the control of sucrose adulteration in honey. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Microextraction by Packed Sorbent (MEPS) and Solid-Phase Microextraction (SPME) as Sample Preparation Procedures for the Metabolomic Profiling of Urine

    PubMed Central

    Silva, Catarina; Cavaco, Carina; Perestrelo, Rosa; Pereira, Jorge; Câmara, José S.

    2014-01-01

    For a long time, sample preparation was unrecognized as a critical issue in the analytical methodology, thus limiting the performance that could be achieved. However, the improvement of microextraction techniques, particularly microextraction by packed sorbent (MEPS) and solid-phase microextraction (SPME), completely modified this scenario by introducing unprecedented control over this process. Urine is a biological fluid that is very interesting for metabolomics studies, allowing human health and disease characterization in a minimally invasive form. In this manuscript, we will critically review the most relevant and promising works in this field, highlighting how the metabolomic profiling of urine can be an extremely valuable tool for the early diagnosis of highly prevalent diseases, such as cardiovascular, oncologic and neurodegenerative ones. PMID:24958388

  19. Comparison of characteristic flavor and aroma volatiles in melons and standards using solid phase microextraction (SPME) and Stir Bar Sorptive Extraction (SBSE) with GC-MS.

    USDA-ARS?s Scientific Manuscript database

    Stir bar sorptive extraction (SBSE) is a technique for extraction and analysis of organic compounds in aqueous matrices, similar in theory to solid phase microextraction (SPME). SBSE has been successfully used to analyze several organic compounds, including food matrices. When compared with SPME, ...

  20. Determination of arsenic and selenium by hydride generation and headspace solid phase microextraction coupled with optical emission spectrometry

    NASA Astrophysics Data System (ADS)

    Tyburska, Anna; Jankowski, Krzysztof; Rodzik, Agnieszka

    2011-07-01

    A hydride generation headspace solid phase microextraction technique has been developed in combination with optical emission spectrometry for determination of total arsenic and selenium. Hydrides were generated in a 10 mL volume septum-sealed vial and subsequently collected onto a polydimethylsiloxane/Carboxen solid phase microextraction fiber from the headspace of sample solution. After completion of the sorption, the fiber was transferred into a thermal desorption unit and the analytes were vaporized and directly introduced into argon inductively coupled plasma or helium microwave induced plasma radiation source. Experimental conditions of hydride formation reaction as well as sorption and desorption of analytes have been optimized showing the significant effect of the type of the solid phase microextraction fiber coating, the sorption time and hydrochloric acid concentration of the sample solution on analytical characteristics of the method developed. The limits of detection of arsenic and selenium were 0.1 and 0.8 ng mL - 1 , respectively. The limit of detection of selenium could be improved further using biosorption with baker's yeast Saccharomyces cerevisiae for analyte preconcentration. The technique was applied for the determination of total As and Se in real samples.

  1. Analysis of potassium formate in airport storm water runoff by headspace solid-phase microextraction and gas chromatography-mass spectrometry.

    PubMed

    Fries, Elke; Klasmeier, Jörg

    2009-01-30

    Potassium formate was extracted from airport storm water runoff by headspace solid-phase microextraction (HS-SPME) and analyzed by GC-MS. Formate was transformed to formic acid by adding phosphoric acid. Subsequently, formic acid was derivatized to methyl formate by adding methanol. Using sodium [(2)H]formate (formate-d) as an internal standard, the relative standard deviation of the peak area ratio of formate (m/z 60) and formate-d (m/z 61) was 0.6% at a concentration of 208.5 mg L(-1). Calibration was linear in the range of 0.5-208.5 mg L(-1). The detection limit calculated considering the blank value was 0.176 mg L(-1). The mean concentration of potassium formate in airport storm water runoff collected after surface de-icing operations was 86.9 mg L(-1) (n=11) with concentrations ranging from 15.1 mg L(-1) to 228.6 mg L(-1).

  2. Applicability of solid-phase microextraction combined with gas chromatography atomic emission detection (GC-MIP AED) for the determination of butyltin compounds in sediment samples.

    PubMed

    Carpinteiro, J; Rodríguez, I; Cela, R

    2004-11-01

    The performance of solid-phase microextraction (SPME) applied to the determination of butyltin compounds in sediment samples is systematically evaluated. Matrix effects and influence of blank signals on the detection limits of the method are studied in detail. The interval of linear response is also evaluated in order to assess the applicability of the method to sediments polluted with butyltin compounds over a large range of concentrations. Advantages and drawbacks of including an SPME step, instead of the classic liquid-liquid extraction of the derivatized analytes, in the determination of butyltin compounds in sediment samples are considered in terms of achieved detection limits and experimental effort. Analytes were extracted from the samples by sonication using glacial acetic acid. An aliquot of the centrifuged extract was placed on a vial where compounds were ethylated and concentrated on a PDMS fiber using the headspace mode. Determinations were carried out using GC-MIP AED.

  3. [Developments in preparation and experimental method of solid phase microextraction fibers].

    PubMed

    Yi, Xu; Fu, Yujie

    2004-09-01

    Solid phase microextraction (SPME) is a simple and effective adsorption and desorption technique, which concentrates volatile or nonvolatile compounds from liquid samples or headspace of samples. SPME is compatible with analyte separation and detection by gas chromatography, high performance liquid chromatography, and other instrumental methods. It can provide many advantages, such as wide linear scale, low solvent and sample consumption, short analytical times, low detection limits, simple apparatus, and so on. The theory of SPME is introduced, which includes equilibrium theory and non-equilibrium theory. The novel development of fiber preparation methods and relative experimental techniques are discussed. In addition to commercial fiber preparation, different newly developed fabrication techniques, such as sol-gel, electronic deposition, carbon-base adsorption, high-temperature epoxy immobilization, are presented. Effects of extraction modes, selection of fiber coating, optimization of operating conditions, method sensitivity and precision, and systematical automation, are taken into considerations in the analytical process of SPME. A simple perspective of SPME is proposed at last.

  4. Evaluation of a headspace solid-phase microextraction method for the analysis of ignitable liquids in fire debris.

    PubMed

    Fettig, Ina; Krüger, Simone; Deubel, Jan H; Werrel, Martin; Raspe, Tina; Piechotta, Christian

    2014-05-01

    The chemical analysis of fire debris represents a crucial part in fire investigations to determine the cause of a fire. A headspace solid-phase microextraction (HS-SPME) procedure for the detection of ignitable liquids in fire debris using a fiber coated with a mixture of three different sorbent materials (Divinylbenzene/Carboxen/Polydimethylsiloxane, DVB/CAR/PDMS) is described. Gasoline and diesel fuel were spiked upon a preburnt matrix (wood charcoal), extracted and concentrated with HS-SPME and then analyzed with gas chromatography/mass spectrometry (GC/MS). The experimental conditions--extraction temperature, incubation and exposure time--were optimized. To assess the applicability of the method, fire debris samples were prepared in the smoke density chamber (SDC) and a controlled-atmosphere cone calorimeter. The developed methods were successfully applied to burnt particleboard and carpet samples. The results demonstrate that the procedure that has been developed here is suitable for detecting these ignitable liquids in highly burnt debris. © 2013 American Academy of Forensic Sciences.

  5. Determination of 17 kinds of banned organochlorine pesticides in water by activated carbon fiber-solid phase microextraction coupled with GC-MS.

    PubMed

    Sun, Tonghua; Jia, Jinping; Zhong, Dengjie; Wang, Yalin

    2006-02-01

    Activated carbon fiber (ACF) as extraction fiber for solid-phase microextraction (SPME) and its application for the analysis of banned organochlorine pesticides (OCPs) were investigated. Firstly, ACF was activated by different concentration of zinc chloride, which indicated that ACF activated by 60% zinc chloride had a reasonable specific surface area, pore volume and pore distribution. Secondly, the parameters for the ACF-SPME procedure, the adsorption and desorption conditions, were also optimized when coupled with gas chromatography-mass spectrometry (GC-MS). Thirdly, the ACF-SPME was used to analyze 17 kinds of OCPs in water. The linearity of most pesticides was found to be between 0.2 and 50 microg/l with GC-MS under the selected ion monitoring (SIM) acquisition mode. The limits of detection (LOD) at the sub microg/l were obtained. The work demonstrated here shows that ACF is a promising alternative for the SPME procedure.

  6. Adjusted active carbon fibers for solid phase microextraction.

    PubMed

    Jia, Jinping; Feng, Xue; Fang, Nenghu; Wang, Yalin; Chen, Hongjin; Dan, Wu

    2002-01-01

    Adjusted active carbon fiber (AACF) was evaluated for Solid Phase Microextraction (SPME), which showed higher sensitivity and stability than traditional coating fibers. The characteristics of AACF result from two different activation methods (chemical and water vapor) and from variable activation conditions (temperature and time). The fiber treated by water vapor appears to have stronger affinity to polar compounds, while that treated by chemical activation appears to have stronger affinity to non-polar compounds. For different target compounds ranged from non-polar to polar, AACF design could be effective with specific selections and sensitivities. As applications in this paper, benzoic acid in soy sauce was extracted onto water-vapor-activated-fiber, then analyzed using gas chromatograph-mass spectrometer (GC-MS). The chemical-activated-fiber SPME was applied in the analysis of benzene series compounds (BTEX) in water matrix. Compared with standard carbon disulfide extraction method, chemical-activated-fiber SPME is more convenient due to its simple process and turns to be of relative low detection limits.

  7. Evaluation of needle trap micro-extraction and automatic alveolar sampling for point-of-care breath analysis.

    PubMed

    Trefz, Phillip; Rösner, Lisa; Hein, Dietmar; Schubert, Jochen K; Miekisch, Wolfram

    2013-04-01

    Needle trap devices (NTDs) have shown many advantages such as improved detection limits, reduced sampling time and volume, improved stability, and reproducibility if compared with other techniques used in breath analysis such as solid-phase extraction and solid-phase micro-extraction. Effects of sampling flow (2-30 ml/min) and volume (10-100 ml) were investigated in dry gas standards containing hydrocarbons, aldehydes, and aromatic compounds and in humid breath samples. NTDs contained (single-bed) polymer packing and (triple-bed) combinations of divinylbenzene/Carbopack X/Carboxen 1000. Substances were desorbed from the NTDs by means of thermal expansion and analyzed by gas chromatography-mass spectrometry. An automated CO2-controlled sampling device for direct alveolar sampling at the point-of-care was developed and tested in pilot experiments. Adsorption efficiency for small volatile organic compounds decreased and breakthrough increased when sampling was done with polymer needles from a water-saturated matrix (breath) instead from dry gas. Humidity did not affect analysis with triple-bed NTDs. These NTDs showed only small dependencies on sampling flow and low breakthrough from 1-5 %. The new sampling device was able to control crucial parameters such as sampling flow and volume. With triple-bed NTDs, substance amounts increased linearly with increasing sample volume when alveolar breath was pre-concentrated automatically. When compared with manual sampling, automatic sampling showed comparable or better results. Thorough control of sampling and adequate choice of adsorption material is mandatory for application of needle trap micro-extraction in vivo. The new CO2-controlled sampling device allows direct alveolar sampling at the point-of-care without the need of any additional sampling, storage, or pre-concentration steps.

  8. Field and Laboratory Application of a Gas Chromatograph Low Thermal Mass Resistively Heated Column System in Detecting Traditional and Non-Traditional Chemical Warfare Agents Using Solid Phase Micro-Extraction

    DTIC Science & Technology

    2005-02-01

    followed by extensive sample preparation procedures that are performed in a laboratory. Analysis is typically conducted by injecting a liquid or gas sample...Alfentanil, Remifentanil , Sufentanil, and Carfentanil) in a laboratory. (5) Quantitatively determine a maximum temperature ramping rate at which the LTM...RHT Column combined with a GC-MS can separate and analyze a mixture of non- traditional CWAs (i.e. Fentanyl, Alfentanil, Remifentanil , Sufentanil

  9. Comparative evaluation of liquid-liquid extraction, solid-phase extraction and solid-phase microextraction for the gas chromatography-mass spectrometry determination of multiclass priority organic contaminants in wastewater.

    PubMed

    Robles-Molina, José; Gilbert-López, Bienvenida; García-Reyes, Juan F; Molina-Díaz, Antonio

    2013-12-15

    The European Water Framework Directive (WFD) 2000/60/EC establishes guidelines to control the pollution of surface water by sorting out a list of priority substances that involves a significant risk to or via the aquatic systems. In this article, the analytical performance of three different sample preparation methodologies for the GC-MS/MS determination of multiclass organic contaminants-including priority comprounds from the WFD-in wastewater samples using gas chromatography-mass spectrometry was evaluated. The methodologies tested were: (a) liquid-liquid extraction (LLE) with n-hexane; (b) solid-phase extraction (SPE) with C18 cartridges and elution with ethyl acetate:dichloromethane (1:1 (v/v)), and (c) headspace solid-phase microextraction (HS-SPME) using two different fibers: polyacrylate and polydimethylsiloxane/carboxen/divinilbenzene. Identification and confirmation of the selected 57 compounds included in the study (comprising polycyclic aromatic hydrocarbons (PAHs), pesticides and other contaminants) were accomplished using gas chromatography tandem mass spectrometry (GC-MS/MS) with a triple quadrupole instrument operated in the multiple reaction monitoring (MRM) mode. Three MS/MS transitions were selected for unambiguous confirmation of the target chemicals. The different advantages and pitfalls of each method were discussed. In the case of both LLE and SPE procedures, the method was validated at two different concentration levels (15 and 150 ng L(-1)) obtaining recovery rates in the range 70-120% for most of the target compounds. In terms of analyte coverage, results with HS-SPME were not satisfactory, since 14 of the compounds tested were not properly recovered and the overall performance was worse than the other two methods tested. LLE, SPE and HS-SPME (using polyacrylate fiber) procedures also showed good linearity and precision. Using any of the three methodologies tested, limits of quantitation obtained for most of the detected compounds were in the low nanogram per liter range. © 2013 Elsevier B.V. All rights reserved.

  10. Development of new method of δ13C measurement for trace hydrocarbons in natural gas using solid phase micro-extraction coupled to gas chromatography isotope ratio mass spectrometry.

    PubMed

    Li, Zhongping; Wang, Xibin; Li, Liwu; Zhang, Mingjie; Tao, Mingxin; Xing, Lantian; Cao, Chunhui; Xia, Yanqing

    2014-11-01

    Compound specific isotope analysis (CSIA) of normal-level hydrocarbons (C 1 -C 4 ) in natural gas is often successfully used in natural gas origin identification and classification, but little progress so far has been made for trace level hydrocarbons (C 5 -C 14 ) in natural gas. In this study, we developed a method for rapid analysis of carbon isotopic ratios for trace hydrocarbons in natural gas samples. This method can be described as a combined approach characterized by solid phase micro-extraction (SPME) technique coupled to gas chromatography isotope ratio mass spectrometry (GC/IRMS). In this study, the CAR-PDMS fiber was chosen as the SPME adsorptive material after comparative experiments with other four fibers, and the parameters, including equilibration time, extraction temperature and desorption time, for efficient extraction of trace hydrocarbons were systematically optimized. The results showed the carbon isotopic fractionation was not observed as a function of equilibration time and extraction temperature. And the δ 13 C signatures determined by SPME-GC/IRMS were in good agreement with the known δ 13 C values of C 5 -C 14 measured by GC-IRMS, and the accuracy is generally within ±0.5‰. Five natural gas samples were analyzed using this method, and the δ 13 C values for C 5 -C 14 components were obtained with satisfied repeatability. The SPME-GC/IRMS approach fitted with CAR-PDMS fiber is well suited for the preconcentration of trace hydrocarbons and provides so far the most reliable carbon isotopic analysis for trace compounds in natural gas. Published by Elsevier B.V.

  11. Solid-phase microextraction of hydrocarbons from water in a centrifuge

    NASA Astrophysics Data System (ADS)

    Ryabov, A. Yu.; Chuikin, A. V.; Velikov, A. A.

    2016-06-01

    The results of our study of solid-phase microextraction of substances using a centrifuge for determining the microquantities of hydrocarbon impurities in water are presented. The cartridge diameter, sorbent mass, and solvent volume were shown to affect the percent extraction of substances and the analytical signal intensity. The relationship between the cartridge geometry, the sorbent mass, and the solvent volume was considered.

  12. Characterisation of volatile profiles in 50 native Peruvian chili pepper using solid phase microextraction-gas chromatography mass spectrometry (SPME-GCMS).

    PubMed

    Patel, Kirti; Ruiz, Candy; Calderon, Rosa; Marcelo, Mavel; Rojas, Rosario

    2016-11-01

    The volatiles were characterised by headspace solid phase micro extraction (HS-SPME), gas chromatography mass spectrometry (GC-FID/MS). A total of 127 compounds were identified with terpenes (including mono terpenes and sesquiterpenes - a total of 45 compounds), esters (31 compounds) and hydrocarbons (20 compounds) were the predominant volatile compounds. Principal component analysis (PCA) of the volatile compounds yielded 2 significant PC's, which together accounted for 90.3% of the total variance in the data set and the scatter plot generated between PC1 and PC2 successfully segregated the 50 chili pepper samples into 7 groups. Clusters of hydrocarbons, esters, terpenes, aldehyde and ketones formed the major determinants of the difference. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Solid-phase microfibers based on polyethylene glycol modified single-walled carbon nanotubes for the determination of chlorinated organic carriers in textiles.

    PubMed

    Zhang, Wei-Ya; Sun, Yin; Wang, Cheng-Ming; Wu, Cai-Ying

    2011-09-01

    Based on polyethylene glycol modified single-walled carbon nanotubes, a novel sol-gel fiber coating was prepared and applied to the headspace microextraction of chlorinated organic carriers (COCs) in textiles by gas chromatography-electron capture detection. The preparation of polyethylene glycol modified single-walled carbon nanotubes and the sol-gel fiber coating process was stated and confirmed by infrared spectra, Raman spectroscopy, and scanning electron microscopy. Several parameters affecting headspace microextraction, including extraction temperature, extraction time, salting-out effect, and desorption time, were optimized by detecting 11 COCs in simulative sweat samples. Compared with the commercial solid-phase microextraction fibers, the sol-gel polyethylene glycol modified single-walled carbon nanotubes fiber showed higher extraction efficiency, better thermal stability, and longer life span. The method detection limits for COCs were in the range from 0.02 to 7.5 ng L(-1) (S/N = 3). The linearity of the developed method varied from 0.001 to 50 μg L(-1) for all analytes, with coefficients of correlation greater than 0.974. The developed method was successfully applied to the analysis of trace COCs in textiles, the recoveries of the analytes indicated that the developed method was considerably useful for the determination of COCs in ecological textile samples.

  14. Facile preparation of multifunctional carbon nanotube/magnetite/polyaniline nanocomposite offering a strong option for efficient solid-phase microextraction coupled with GC-MS for the analysis of phenolic compounds.

    PubMed

    Tafazoli, Zahra; Azar, Parviz Aberoomand; Tehrani, Mohammad Saber; Husain, Syed Waqif

    2018-04-20

    The aim of this study the synthesis of a highly efficient organic-inorganic nanocomposite. In this research, the carbon nanotube/magnetite/polyaniline nanocomposite was successfully prepared through a facile route. Monodisperse magnetite nanospheres were prepared through the coprecipitation route, and polyaniline nanolayer as a modified shell with a high surface area was synthesized by an in situ growth route and characterized by Fourier transform infrared spectroscopy, scanning electron microscopy, X-ray diffraction and energy dispersive X-ray spectroscopy. The prepared nanocomposite was immobilized on a stainless-steel wire for the fabrication of the solid-phase microextraction fiber. The combination of headspace solid-phase microextraction using carbon nanotube/magnetite/polyaniline nanocomposite fiber with gas chromatography and mass spectrometry can achieve a low limit of detection and can be applied to determine phenolic compounds in water samples. The effects of the extraction and desorption parameters including extraction temperature and time, ionic strength, stirring rate, pH, and desorption temperature and time have been studied. Under the optimum conditions, the dynamic linear range was 0.01-500 ng mL -1 and the limits of detection of phenol, 4-chlorophenol, 2,6-dichlorophenol, and 2,4,6-trichlorophenol were the lowest (0.008 ng mL -1 ) for three times. The coefficient of determination of all calibration curves was more than 0.990. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  15. A silica fiber coated with a ZnO-graphene oxide nanocomposite with high specific surface for use in solid phase microextraction of the antiepileptic drugs diazepam and oxazepam.

    PubMed

    Alizadeh, Reza; Salami, Maryam; Seidi, Shahram

    2018-06-02

    A novel ZnO-graphene oxide nanocomposite was prepared and is shown to be a viable coating on fused silica fibers for use in solid phase microextraction (SPME) of diazepam and oxazepam from urine, this followed by thermal desorption and gas chromatographic quantitation using a flame ionization detector. A central composite design was used to optimize extraction time, salt percentage, sample pH and desorption time. Limits of detection are 0.5 μg·L -1 for diazepam and 1.0 μg·L -1 for oxazepam. Repeatability and reproducibility for one fiber (n = 4), expressed as the relative standard deviation at a concentration of 50 μg·L -1 , are 8.3 and 11.3% for diazepam, and 6.7 and 10.1% for oxazepam. The fiber-to-fiber reproducibility is <17.6%. The calibration plots are linear in the 5.0-1000 μg·L -1 diazepam concentration range, and from 1.0-1000 μg·L -1 in case of oxazepam. The fiber for SPME has high chemical and thermal stability (even at 280 °C) after 50 extractions, and does not suffer from a reduction in the sorption capacity. Graphical abstract A hydrothermal method was introduced for preparation of ZnO- GO nano composite on a fused silica fiber as solid phase microextraction with high mechanical, chemical stability and long service life.

  16. Investigations on the emission of fragrance allergens from scented toys by means of headspace solid-phase microextraction gas chromatography-mass spectrometry.

    PubMed

    Masuck, Ines; Hutzler, Christoph; Luch, Andreas

    2010-04-30

    In the revised European toy safety directive 2009/48/EC the application of fragrance allergens in children's toys is restricted. The focus of the present work lies on the instrumental analytics of 13 banned fragrance allergens, as well as on 11 fragrance allergens that require declaration when concentrations surpass 100 microg per gram material. Applying a mixture of ethyl acetate and toluene solid/liquid extraction was performed prior to quantitative analysis of mass contents of fragrances in scented toys. In addition, an easy-to-perform method for the determination of emitted fragrances at 23 degrees C (handling conditions) or at 40 degrees C (worst case scenario) has been worked out to allow for the evaluation of potential risks originating from inhalation of these compounds during handling of or playing with toys. For this purpose a headspace solid-phase microextraction (HS-SPME) technique was developed and coupled to subsequent gas chromatography-mass spectrometry (GC-MS) analysis. Fragrance allergens were adsorbed (extracted) from the gas phase onto an 85 microm polyacrylate fiber while incubating pieces of the scented toys in sealed headspace vials at 23 degrees C and 40 degrees C. Quantification of compounds was performed via external calibration. The newly developed headspace method was subsequently applied to five perfumed toys. As expected, the emission of fragrance allergens from scented toys depends on the temperature and on the content of fragrance allergens present in those samples. In particular at conditions mimicking worst case (40 degrees C), fragrance allergens in toys may pose a risk to children since considerable amounts of compound might be absorbed by lung tissue via breathing of contaminated air. 2010 Elsevier B.V. All rights reserved.

  17. Enantioselective determination of the organochlorine pesticide bromocyclen in spiked fish tissue using solid-phase microextraction coupled to gas chromatography with ECD and ICP-MS detection.

    PubMed

    Fidalgo-Used, Natalia; Montes-Bayón, Maria; Blanco-González, Elisa; Sanz-Medel, Alfredo

    2008-05-15

    A method for enantioselective determination of bromocyclen enantiomers in fish tissue has been developed. The enantiomers were resolved by capillary gas chromatography (GC) using a commercial chiral column (CP-Chirasil-Dex CB) and a temperature program from 50 degrees C (held for 1 min), raised to 140 degrees C at 40 degrees C min(-1) and then raised at 0.2 degrees C min(-1) to 155 degrees C. This enantioselective gas chromatographic separation was combined with a clean-up/enrichment procedure based on solid-phase microextraction (SPME). Under SPME optimized conditions, precision, linearity range and detection limits of the developed SPME-enantioselective GC procedure were evaluated and compared using two different detection systems: a classical electron-capture detection (ECD) and an element specific detection using inductively coupled plasma mass spectrometry (ICP-MS). The SPME-GC-ECD method exhibited an excellent sensitivity, with detection limits of 0.2 ng L(-1) for each enantiomer of bromocyclen. Although ICP-MS offered poorer detection limits (7 ng L(-1) as Br, equivalent to 36 ng L(-1) of each enantiomer) than conventional ECD detector, it proved to be clearly superior in terms of selectivity. The relative potential and performance of the two compared methods for real-life analysis has been illustrated by the determination of enantiomers of bromocyclen in spiked tissue extracts of trout.

  18. Extraction and preconcentration of residual solvents in pharmaceuticals using dynamic headspace-liquid phase microextraction and their determination by gas chromatography-flame ionization detection.

    PubMed

    Farajzadeh, Mir Ali; Dehghani, Hamideh; Yadeghari, Adeleh; Khoshmaram, Leila

    2017-02-01

    The present study describes a microextraction and determination method for analyzing residual solvents in pharmaceutical products using dynamic headspace-liquid phase microextraction technique followed by gas chromatography-flame ionization detection. In this method dimethyl sulfoxide (μL level) placed into a GC liner-shaped extraction vessel is used as a collection/extraction solvent. Then the liner is exposed to the headspace of a vial containing the sample solution. The effect of different parameters influencing the microextraction procedure including collection/extraction solvent type and its volume, ionic strength, extraction time, extraction temperature and concentration of NaOH solution used in dissolving the studied pharmaceuticals are investigated and optimized. Under the optimum extraction conditions, the method showed wide linear ranges between 0.5 and 5000 mg L -1 . The other analytical parameters were obtained in the following ranges: enrichment factors 240-327, extraction recoveries 72-98% and limits of detection 0.1-0.8 mg L -1 in solution and 0.6-3.2 μg g -1 in solid. Relative standard deviations for the extraction of 100 mg L -1 of each analyte were obtained in the ranges of 4-7 and 5-8% for intra-day (n = 6) and inter-day (n = 4) respectively. Finally the target analytes were determined in different samples such as erythromycin, azithromycin, cefalexin, amoxicillin and co-amoxiclav by the proposed method. Copyright © 2016 John Wiley & Sons, Ltd.

  19. Rapid determination of 54 pharmaceutical and personal care products in fish samples using microwave-assisted extraction-Hollow fiber-Liquid/solid phase microextraction.

    PubMed

    Zhang, Yi; Guo, Wen; Yue, Zhenfeng; Lin, Li; Zhao, Fengjuan; Chen, Peijin; Wu, Weidong; Zhu, Hong; Yang, Bo; Kuang, Yanyun; Wang, Jiong

    2017-04-15

    In this paper, a simple, rapid, solvent-less and environmental friendliness microextraction method, microwave-assisted extraction-hollow fiber-liquid/solid phase microextraction (MAE-HF-L/SME), was developed for simultaneous extraction and enrichment of 54 trace hydrophilic/lipophilic pharmaceutical and personal care products (PPCPs) from fish samples. A solid-phase extraction material, solid-phase microextraction (SPME) fiber, was synthesized. The SPME fiber had a homogeneous, loose structure and good mechanical properties, and they exhibited a good adsorption capacity for most PPCPs selected. The material formed the basis for the method of MAE-HF-L/SME. A method of liquid chromatography-high resolution mass spectroscopy (LC-HRMS) for analysis of 54 PPCPs. Under optimal synthesis and extraction conditions, the limits of detection (LODs, n=3) and the limits of quantitation (LOQs, n=10) for the 54 PPCPs were between 0.01-0.50μg·kg -1 and 0.052.00μg·kg -1 , respectively. Percent recoveries and the relative standard deviations (RSDs) in spiked fish samples (n=6) were between 56.3%-119.9% and 0.3%-17.1%, respectively. The microextraction process of 54 PPCPs in MAE-HF-L/SME took approximately 12min. The method has a low matrix interference and high enrichment factor and may be applicable for determination of 54 different PPCPs in fish samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Simultaneous sampling and analysis of indoor air infested with Cimex lectularius L. (Hemiptera: Cimicidae) by solid phase microextraction, thin film microextraction and needle trap device.

    PubMed

    Eom, In-Yong; Risticevic, Sanja; Pawliszyn, Janusz

    2012-02-24

    Air in a room infested by Cimex lectularius L. (Hemiptera: Cimicidae) was sampled simultaneously by three different sampling devices including solid phase microextraction (SPME) fiber coatings, thin film microextraction (TFME) devices, and needle trap devices (NTDs) and then analyzed by gas chromatography-mass spectrometry (GC-MS). The main focus of this study was to fully characterize indoor air by identifying compounds extracted by three different microextraction formats and, therefore, perform both the device comparison and more complete characterization of C. lectularius pheromone. The NTD technique was capable of extracting both (E)-2-hexenal and (E)-2-octenal, which were previously identified as alarm pheromones of bedbugs, and superior NTD recoveries for these two components allowed reliable identification based on mass spectral library searching and linear temperature programmed retention index (LTPRI) technique. While the use of DVB/CAR/PDMS SPME fiber coatings provided complementary sample fingerprinting and profiling results, TFME sampling devices provided discriminative extraction coverage toward highly volatile analytes. In addition to two alarm pheromones, relative abundances of all other analytes were recorded for all three devices and aligned across all examined samples, namely, highly infested area, less infested area, and control samples which were characterized by different bedbug populations. The results presented in the current study illustrate comprehensive characterization of infested indoor air samples through the use of three different non-invasive SPME formats and identification of novel components comprising C. lectularius pheromone, therefore, promising future alternatives for use of potential synthetic pheromones for detection of infestations. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Solid-phase microextraction followed by gas chromatography-mass spectrometry for the determination of ink photo-initiators in packed milk.

    PubMed

    Negreira, N; Rodríguez, I; Rubí, E; Cela, R

    2010-06-30

    A novel, single step method for the determination of seven ink photo-initiators in carton packed milk samples is described. Solid-phase microextraction (SPME) and gas chromatography (GC), combined with mass spectrometry (MS), were used as sample preparation and determination techniques, respectively. Parameters affecting the performance of the microextraction process were thoroughly evaluated using uni- and multivariate optimization strategies, based on the use of experimental factorial designs. The coating of the SPME fibre, together with the sampling mode and the temperature were the factors playing a major influence on the efficiency of the extraction. Under final conditions, 1.5 mL of milk and 8.5 mL of ultrapure water were poured in a glass vessel, which was closed and immersed in a water boiling bath. A poly(dimethylsiloxane)-divinylbenzene (PDMS-DVB) coated fibre was exposed directly to the diluted sample for 40 min. After that, the fibre was desorbed in the injector of the GC-MS system for 3 min. The optimized method provided limits of quantification (LOQs) between 0.2 and 1 microg L(-1) and a good linearity in the range between 1 and 250 microg L(-1). The inter-day precision remained below 15% for all compounds in spiked whole milk. The efficiency of the extraction changed for whole, semi-skimmed and skimmed milk; however, no differences were noticed among the relative recoveries achieved for milk samples, from different brands, with the same fat content. Copyright 2010 Elsevier B.V. All rights reserved.

  2. Cork as a new (green) coating for solid-phase microextraction: determination of polycyclic aromatic hydrocarbons in water samples by gas chromatography-mass spectrometry.

    PubMed

    Dias, Adriana Neves; Simão, Vanessa; Merib, Josias; Carasek, Eduardo

    2013-04-15

    A new fiber for solid-phase microextraction (SPME) was prepared employing cork as a coating. The morphology and composition of the cork fiber was evaluated by scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FTIR), respectively. The proposed fiber was used for the determination of polycyclic aromatic hydrocarbons (PAHs) in river water samples by gas chromatography-selected ion monitoring-mass spectrometry (GC-SIM-MS). A central composite design was used for optimization of the variables involved in the extraction of PAHs from water samples. The optimal extraction conditions were extraction time and temperature of 60 min and 80°C, respectively. The detection and quantification limits were 0.03 and 0.1 μg L(-1), respectively. The recovery values were between 70.2 and 103.2% and the RSD was ≤15.7 (n=3). The linear range was 0.1-10 μg L(-1) with r≥0.96 and the fiber-to-fiber reproducibility showed RSD≤18.6% (n=5). The efficiency of the cork fiber was compared with commercially available fibers and good results were achieved, demonstrating the applicability and great potential of cork as a coating for SPME. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Characterization of the volatile profiles of beer using headspace solid-phase microextraction and gas chromatography-mass spectrometry.

    PubMed

    Rossi, Serena; Sileoni, Valeria; Perretti, Giuseppe; Marconi, Ombretta

    2014-03-30

    The objective of this study was a multivariate characterization of the volatile profile of beers. Such a characterization is timely considering the increasing worldwide consumption of beer, the continuous growth of microbreweries and the importance of volatile compounds to beer flavour. A method employing solid-phase microextraction and gas chromatography-mass spectrometry (SPME-GC-MS) was optimized and then applied to a sample set of 36 industrial and craft beers of various styles and fermentation types. The volatile profiles of different beer styles is described, with particular attention paid to the volatile compounds characteristic of a spontaneously fermented lambic raspberry framboise beer. Furthermore, it was also possible to identify which specific volatile compounds are principally responsible for the differences in the volatile profiles of top- and bottom-fermented beers. Moreover, a volatile fingerprint of the craft top-fermented Italian beers was defined, as they show a very similar volatile profile. Finally, the volatile compounds that are characteristic of the bock-style beers are described. The SPME-GC-MS analytical method optimized in this study is suitable for characterizing the volatile fingerprint of different beers, especially on the basis of the kind of fermentation (top, bottom or spontaneous), the method of production and the style of the beer. © 2013 Society of Chemical Industry.

  4. Silica-based ionogels: nanoconfined ionic liquid-rich fibers for headspace solid-phase microextraction coupled with gas chromatography-barrier discharge ionization detection.

    PubMed

    Pena-Pereira, Francisco; Marcinkowski, Lukasz; Kloskowski, Adam; Namieśnik, Jacek

    2014-12-02

    In this work, hybrid silica-based materials with immobilized ionic liquids (ILs) were prepared by sol-gel technology and evaluated as solid-phase microextraction (SPME) fiber coatings. High loadings of the IL 1-methyl-3-butylimidazolium bis(trifluoromethylsulfonyl)imide ([C4MIM][TFSI]) were confined within the hybrid network. Coatings composition and morphology were evaluated using scanning electron microscopy and energy dispersive X-ray spectrometry. The obtained ionogel SPME fibers exhibited high extractability for aromatic volatile compounds, yielding good sensitivity and precision when combined with a gas chromatograph with barrier ionization discharge (GC-BID) detection. A central composite design was used for assessing the effect of experimental parameters on the extraction process. Under optimized conditions, the proposed ionogel SPME fiber coatings enabled the achievement of excellent enrichment factors (up to 7400). The limits of detection (LODs) were found in the range 0.03-1.27 μg L(-1), whereas the repeatability and fiber-to-fiber reproducibility were 5.6% and 12.0% on average, respectively. Water samples were analyzed by the proposed methodology, showing recovery values in the range of 88.7-113.9%. The results obtained in this work suggest that ionogels can be promising coating materials for future applications of SPME and related sample preparation techniques.

  5. Odour-causing compounds in air samples: gas-liquid partition coefficients and determination using solid-phase microextraction and GC with mass spectrometric detection.

    PubMed

    Godayol, Anna; Alonso, Mònica; Sanchez, Juan M; Anticó, Enriqueta

    2013-03-01

    A quantification method based on solid-phase microextraction followed by GC coupled to MS was developed for the determination of gas-liquid partition coefficients and for the air monitoring of a group of odour-causing compounds that had previously been found in wastewater samples including dimethyl disulphide, phenol, indole, skatole, octanal, nonanal, benzothiazole and some terpenes. Using a divinylbenzene/carboxen/polydimethylsiloxane fibre, adsorption kinetics have been studied to define an extraction time that would avoid coating saturation. It was found that for an extraction time of 10 min, external calibration could be performed in the range of 0.4-100 μg/m(3), with detection limits between 0.1 and 20 μg/m(3). Inter-day precision of the developed method was evaluated (n = 5) and RSD values between 12 and 24% were obtained for all compounds. The proposed method has been applied to the analysis of air samples surrounding a wastewater treatment plant in Catalonia (Spain). In all air samples evaluated, dimethyl disulphide, limonene and phenol were detected, and the first two were the compounds that showed the highest partition coefficients. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Improvement of a headspace solid phase microextraction-gas chromatography/mass spectrometry method for the analysis of wheat bread volatile compounds.

    PubMed

    Raffo, Antonio; Carcea, Marina; Castagna, Claudia; Magrì, Andrea

    2015-08-07

    An improved method based on headspace solid phase microextraction combined with gas chromatography-mass spectrometry (HS-SPME/GC-MS) was proposed for the semi-quantitative determination of wheat bread volatile compounds isolated from both whole slice and crust samples. A DVB/CAR/PDMS fibre was used to extract volatiles from the headspace of a bread powdered sample dispersed in a sodium chloride (20%) aqueous solution and kept for 60min at 50°C under controlled stirring. Thirty-nine out of all the extracted volatiles were fully identified, whereas for 95 other volatiles a tentative identification was proposed, to give a complete as possible profile of wheat bread volatile compounds. The use of an array of ten structurally and physicochemically similar internal standards allowed to markedly improve method precision with respect to previous HS-SPME/GC-MS methods for bread volatiles. Good linearity of the method was verified for a selection of volatiles from several chemical groups by calibration with matrix-matched extraction solutions. This simple, rapid, precise and sensitive method could represent a valuable tool to obtain semi-quantitative information when investigating the influence of technological factors on volatiles formation in wheat bread and other bakery products. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Determination of glutaraldehyde in water samples by headspace solid-phase microextraction and gas chromatography-mass spectrometry after derivatization with 2,2,2-trifluoroethylhydrazine.

    PubMed

    Kang, Hye-In; Shin, Ho-Sang

    2016-05-27

    A simple and convenient headspace solid-phase microextraction (HS-SPME) gas chromatography mass spectrometry (GC-MS) method was described for the determination of glutaraldehyde in water. Glutaraldehyde in water reacted with 2,2,2-trifluoroethylhydrazine (TFEH) in a headspace vial and the formed TFEH derivatives were vaporized and adsorbed onto a fiber. The optimal HS-SPME conditions were achieved with a 50/30μm-divinylbenzene-carboxen-polydimethylsiloxane fiber, 0.06% 2,2,2-TFEH, 25% salt, an extraction/derivatization temperature of 80°C, a heating time of 30min, and a pH of 6.5. The desorption was performed for 1min at 240°C. Under the established conditions, the lowest limits of detection were 0.3μg/L and 0.1μg/L in 6.0mL of surface water and drinking water, respectively, and the intra- and inter-day relative standard deviation was less than 9.1% at concentrations of 50, 100 and 500μg/L. The calibration curve showed good linearity with R=0.9995 and R=0.9993 in surface water and drinking water, respectively. This method is simple, amenable to automation and environmentally friendly. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Application of headspace solid-phase microextraction (HS-SPME) and comprehensive two-dimensional gas chromatography (GC x GC) for the chemical profiling of volatile oils in complex herbal mixtures.

    PubMed

    Di, Xin; Shellie, Robert A; Marriott, Philip J; Huie, Carmen W

    2004-04-01

    The coupling of headspace solid-phase microextraction (HS-SPME) with comprehensive two-dimensional gas chromatography (GC x GC) was shown to be a powerful technique for the rapid sampling and analysis of volatile oils in complex herbal materials. When compared to one-dimensional (1-D) GC, the improved analytical capabilities of GC x GC in terms of increased detection sensitivity and separation power were demonstrated by using HS-SPME/GC x GC for the chemical profiling (fingerprinting) of essential/volatile oils contained in herbal materials of increasing analytical complexity. More than 20 marker compounds belonging to Panax quinquefolius (American ginseng) can be observed within the 2-D contour plots of ginseng itself, a mixture of ginseng and another important herb (P. quinquefolius/Radix angelicae sinensis), as well as a mixture of ginseng and three other herbs (P. quinquefolius /R. angelicae sinensis/R. astragali/R. rehmanniae preparata). Such analytical capabilities should be important towards the authentication and quality control of herbal products, which are receiving increasing attention as alternative medicines worldwide. In particular, the presence of Panax in the herb formulation could be readily identified through its specific peak pattern in the 2-D GC x GC plot.

  9. Rapid determination of amino acids in neonatal blood samples based on derivatization with isobutyl chloroformate followed by solid-phase microextraction and gas chromatography/mass spectrometry.

    PubMed

    Deng, Chunhui; Li, Ning; Zhang, Xiangmin

    2004-01-01

    The purpose of this study was to develop a simple, rapid and sensitive analytical method for determination of amino acids in neonatal blood samples. The developed method involves the employment of derivatization and a solid-phase microextraction (SPME) technique together with gas chromatography/mass spectrometry (GC/MS). Amino acids in blood samples were derivatized by a mixture of isobutyl chloroformate, methanol and pyridine, and the N(O,S)-alkoxycarbonyl alkyl esters thus formed were headspace extracted by a SPME fiber. Finally, the extracted analytes on the fiber were desorbed and detected by GC/MS in electron impact (EI) mode. L-Valine, L-leucine, L-isoleucine, L-phenylanaline and L-tyrosine in blood samples were quantitatively analyzed by measurement of the corresponding N(O,S)-alkoxycarbonyl alkyl esters using an external standard method. SPME conditions were optimized, and the method was validated. The method was applied to diagnosis of neonatal phenylkenuria (PKU) and maple syrup urine disease (MSUD) by the analyses of five amino acids in blood samples. The results showed that the proposed method is a potentially powerful tool for simultaneous screening for neonatal PKU and MSUD. Copyright (c) 2004 John Wiley & Sons, Ltd.

  10. [Determination of nitroaromatics and cyclo ketones in sea water' by gas chromatography coupled with activated carbon fiber solid-phase micro-extraction].

    PubMed

    Ma, Hanna; Zhu, Mengya; Wang, Yalin; Sun, Tonghua; Jia, Jinping

    2009-05-01

    A gas chromatography (GC) coupled with solid-phase micro-extraction using a special activated carbon fiber (ACF) was developed for the analysis of 6 nitroaromatics and cyclic ketones, nitrobenzene (NB), 1,3-dinitrobenzene (1,3-DNB), 2,4-dinitrotoluene (2,4-DNT), 2,6-dinitrotoluene (2,6-DNT), isophorone, 1,4-naphthaquinone (1,4-NPQ), in sea water samples. The sample was extracted for 30 min under saturation of NaCl at 1,500 r/min and 60 degrees C in head space. The desorption was performance at 280 degrees C for 2 min. The linear ranges were from 0.01 to 400 microg/L. The limits of detection (LODs) were 1.4 - 3.2 ng/L. This method has been successfully applied to the determination of nitroaromatics and cyclic ketones in the sea water samples obtained from East China Sea. The concentrations of nitrobenzene, 1,3-dinitrobenzene and 2,6-dinitrotoluene in the sea water sample were 0.756, 0.944, 0.890 microg/L, respectively. The recoveries were 86.3% - 101.8% with the relative standard deviations (RSDs) of 3.7% -7.8%. The method is suitable for analyzing nitroaromatics and cyclic ketones at low concentration levels in sea water samples.

  11. Measurement of isoprene solubility in water, human blood and plasma by multiple headspace extraction gas chromatography coupled with solid phase microextraction.

    PubMed

    Mochalski, Paweł; King, Julian; Kupferthaler, Alexander; Unterkofler, Karl; Hinterhuber, Hartmann; Amann, Anton

    2011-12-01

    The aim of this study was to determine the solubility (liquid-to-air ratios) of isoprene in water, human blood and plasma. To this end, an experimental setup combining multiple headspace extraction, solid phase microextraction and gas chromatography-mass spectrometry was applied. The water:air partition coefficients of isoprene were determined for the temperature range 4.5-37 °C and amounted to 1.171-0.277 (g mL(l)(-1)) (g mL(a)(-1))(-1). On the basis of these data, the enthalpy of volatilization was calculated as 29.46 ± 2.83 kJ mol(-1). The blood:air partition coefficients at 37 °C were determined for ten normal healthy volunteers spread around a median value of 0.95 ± 0.09 (g mL(l)(-1)) (g mL(a)(-1))(-1) and were approximately 16% lower than the plasma:air partition coefficients (1.11 ± 0.2). The applied methodology can be particularly attractive for solubility studies targeting species at very low concentrations in the solution, i.e. when headspace sample enrichment is necessary to provide sufficient measurement sensitivity and reliability. This can be especially helpful if environmental or physiological solute levels have to be considered.

  12. Focused microwave-assisted extraction combined with solid-phase microextraction and gas chromatography-mass spectrometry for the selective analysis of cocaine from coca leaves.

    PubMed

    Bieri, Stefan; Ilias, Yara; Bicchi, Carlo; Veuthey, Jean-Luc; Christen, Philippe

    2006-04-21

    An effective combination of focused microwave-assisted extraction (FMAE) with solid-phase microextraction (SPME) prior to gas chromatography (GC) is described for the selective extraction and quantitative analysis of cocaine from coca leaves (Erythroxylum coca). This approach required switching from an organic extraction solvent to an aqueous medium more compatible with SPME liquid sampling. SPME was performed in the direct immersion mode with a universal 100 microm polydimethylsiloxane (PDMS) coated fibre. Parameters influencing this extraction step, such as solution pH, sampling time and temperature are discussed. Furthermore, the overall extraction process takes into account the stability of cocaine in alkaline aqueous solutions at different temperatures. Cocaine degradation rate was determined by capillary electrophoresis using the short end injection procedure. In the selected extraction conditions, less than 5% of cocaine was degraded after 60 min. From a qualitative point of view, a significant gain in selectivity was obtained with the incorporation of SPME in the extraction procedure. As a consequence of SPME clean-up, shorter columns could be used and analysis time was reduced to 6 min compared to 35 min with conventional GC. Quantitative results led to a cocaine content of 0.70 +/- 0.04% in dry leaves (RSD <5%) which agreed with previous investigations.

  13. Emerging Environmental Contaminants and Soled Phase Microextraction: Janusz Pawliszyn's Legacy in the Environmental Arena

    EPA Science Inventory

    Solid phase microextraction (SPME) has revolutionized the way samples are extracted, enabling rapid, automated, and solventless extraction of many different sample types, including air, water, soil, and biological samples. As such, SPME is widely used for environmental, food, fo...

  14. Development of a sensitive methodology for the analysis of chlorobenzenes in air by combination of solid-phase extraction and headspace solid-phase microextraction.

    PubMed

    Barro, Ruth; Ares, Sergio; Garcia-Jares, Carmen; Llompart, Maria; Cela, Rafael

    2004-08-06

    In this study, a combination of solid-phase extraction (SPE) and solid-phase microextraction (SPME) has been used to determine chlorobenzenes in air. Analytes were sampled by pumping a known volume of air through a porous polymer (Tenax TA). Then, the adsorbent was transferred into a glass vial and SPME was performed. The quantification was carried out using gas chromatography (GC)-electron-capture detection or GC-MS. Several SPME coatings (100 microm poly(dimethylsiloxane) (PDMS), 75 microm Carboxen (CAR)-PDMS, 65 microm PDMS-divinylbenzene (DVB), 65 microm PDMS-DVB and 85 microm polyacrylate (PA) were evaluated, obtaining the highest responses with Carbowax (CW)- PDMS for the most volatile chlorobenzenes, and with PDMS-DVB or CW-DVB fibers for the semivolatile compounds. To optimize some other factors that could affect the SPME step, a factorial design was used. Kinetic studies of the SPME process were also performed. Concerning the SPE step, breakthrough was studied, showing that 2.5 m3 of air could be processed without losses of the most volatile compounds. The performance of the method was evaluated. External calibration, which does not require the complete sampling process, demonstrated to be suitable, obtaining good linearity (R2 > 0.99) for all chlorobenzenes. Recovery studies were performed at two concentration levels (4 and 40 ng/m3), obtaining quantitative recoveries (>80%). Limits of detection at the sub ng/m3 were achieved for all the target compounds.

  15. A rapid space-resolved solid-phase microextraction method as a powerful tool to determine contaminants in wine based on their volatility.

    PubMed

    Liu, Min; Peng, Qing-Qing; Chen, Yu-Feng; Tang, Qian; Feng, Qing

    2015-06-01

    A novel space-resolved solid phase microextraction (SR-SPME) technique was developed to facilitate simultaneously analyte monitoring within heterogeneous samples. Graphene (G) and graphene oxide (GO) were coated separately to the segmented fibers which were successfully used for the solid-phase microextraction of two contaminants with dramatically different volatility: 2,4,6-trichloroanisole (TCA) and dibutyl phthalate (DBP). The space-resolved fiber showed good precision (5.4%, 6.8%), low detection limits (0.3ng/L, 0.3ng/L), and wide linearity (1.0-250.0ng/L, 1.0-250.0ng/L) under the optimized conditions for TCA and DBP, respectively. The method was applied to simultaneous analysis of the two contaminates with satisfactory recoveries, which were 96.96% and 98.20% for wine samples. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Gas flow headspace liquid phase microextraction.

    PubMed

    Yang, Cui; Qiu, Jinxue; Ren, Chunyan; Piao, Xiangfan; Li, Xifeng; Wu, Xue; Li, Donghao

    2009-11-06

    There is a trend towards the use of enrichment techniques such as microextraction in the analysis of trace chemicals. Based on the theory of ideal gases, theory of gas chromatography and the original headspace liquid phase microextraction (HS-LPME) technique, a simple gas flow headspace liquid phase microextraction (GF-HS-LPME) technique has been developed, where the extracting gas phase volume is increased using a gas flow. The system is an open system, where an inert gas containing the target compounds flows continuously through a special gas outlet channel (D=1.8mm), and the target compounds are trapped on a solvent microdrop (2.4 microL) hanging on the microsyringe tip, as a result, a high enrichment factor is obtained. The parameters affecting the enrichment factor, such as the gas flow rate, the position of the microdrop, the diameter of the gas outlet channel, the temperatures of the extracting solvent and of the sample, and the extraction time, were systematically optimized for four types of polycyclic aromatic hydrocarbons. The results were compared with results obtained from HS-LPME. Under the optimized conditions (where the extraction time and the volume of the extracting sample vial were fixed at 20min and 10mL, respectively), detection limits (S/N=3) were approximately a factor of 4 lower than those for the original HS-LPME technique. The method was validated by comparison of the GF-HS-LPME and HS-LPME techniques using data for PAHs from environmental sediment samples.

  17. Analytical methods for the assessment of endocrine disrupting chemical exposure during human fetal and lactation stages: a review.

    PubMed

    Jiménez-Díaz, I; Vela-Soria, F; Rodríguez-Gómez, R; Zafra-Gómez, A; Ballesteros, O; Navalón, A

    2015-09-10

    In the present work, a review of the analytical methods developed in the last 15 years for the determination of endocrine disrupting chemicals (EDCs) in human samples related with children, including placenta, cord blood, amniotic fluid, maternal blood, maternal urine and breast milk, is proposed. Children are highly vulnerable to toxic chemicals in the environment. Among these environmental contaminants to which children are at risk of exposure are EDCs -substances able to alter the normal hormone function of wildlife and humans-. The work focuses mainly on sample preparation and instrumental techniques used for the detection and quantification of the analytes. The sample preparation techniques include, not only liquid-liquid extraction (LLE) and solid-phase extraction (SPE), but also modern microextraction techniques such as extraction with molecular imprinted polymers (MIPs), stir-bar sorptive extraction (SBSE), hollow-fiber liquid-phase microextraction (HF-LPME), dispersive liquid-liquid microextraction (DLLME), matrix solid phase dispersion (MSPD) or ultrasound-assisted extraction (UAE), which are becoming alternatives in the analysis of human samples. Most studies focus on minimizing the number of steps and using the lowest solvent amounts in the sample treatment. The usual instrumental techniques employed include liquid chromatography (LC), gas chromatography (GC) mainly coupled to tandem mass spectrometry. Multiresidue methods are being developed for the determination of several families of EDCs with one extraction step and limited sample preparation. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Application of solid-phase microextraction to the quantitative analysis of 1,8-cineole in blood and expired air in a Eucalyptus herbivore, the brushtail possum (Trichosurus vulpecula).

    PubMed

    Boyle, Rebecca R; McLean, Stuart; Brandon, Sue; Pass, Georgia J; Davies, Noel W

    2002-11-25

    We have developed two solid-phase microextraction (SPME) methods, coupled with gas chromatography, for quantitatively analysing the major Eucalyptus leaf terpene, 1,8-cineole, in both expired air and blood from the common brushtail possum (Trichosurus vulpecula). In-line SPME sampling (5 min at 20 degrees C room temperature) of excurrent air from an expiratory chamber containing a possum dosed orally with 1,8-cineole (50 mg/kg) allowed real-time semi-quantitative measurements reflecting 1,8-cineole blood concentrations. Headspace SPME using 50 microl whole blood collected from possums dosed orally with 1,8-cineole (30 mg/kg) resulted in excellent sensitivity (quantitation limit 1 ng/ml) and reproducibility. Blood concentrations ranged between 1 and 1380 ng/ml. Calibration curves were prepared for two concentration ranges (0.05-10 and 10-400 ng/50 microl) for the analysis of blood concentrations. Both calibration curves were linear (r(2)=0.999 and 0.994, respectively) and the equations for the two concentration ranges were consistent. Copyright 2002 Elsevier Science B.V.

  19. Determination of polychlorinated biphenyls in ocean water and bovine milk using crosslinked polymeric ionic liquid sorbent coatings by solid-phase microextraction.

    PubMed

    Joshi, Manishkumar D; Ho, Tien D; Cole, William T S; Anderson, Jared L

    2014-01-01

    Crosslinked polymeric ionic liquid (PIL)-based sorbent coatings were employed in the extraction of 21 polychlorinated biphenyls (PCBs) from ocean water and bovine milk using solid-phase microextraction (SPME). The extraction temperature, time, and concentration of sodium chloride added to the matrix were optimized in order to determine the best extraction conditions for the extraction of PCBs. The analytical performance of the crosslinked PIL-based SPME fibers was compared with a commercial 7 µm polydimethylsiloxane (PDMS) fiber using gas chromatography (GC) employing an electron capture detector (ECD) and mass spectrometric detection (MS). Higher sensitivities for PCBs were achieved using PIL-based fibers when compared to PDMS fiber due to the incorporation of benzyl moieties into the PIL structures. The limits of detection (LOD) for all PCBs were determined to be in the low ng L(-1) range using the three studied coatings. Recovery studies were performed for PCBs in ocean water and bovine milk to validate the applicability of the current SPME method. © 2013 Published by Elsevier B.V.

  20. Submerged Cultivation of Pleurotus sapidus with Molasses: Aroma Dilution Analyses by Means of Solid Phase Microextraction and Stir Bar Sorptive Extraction.

    PubMed

    Trapp, Tobias; Zajul, Martina; Ahlborn, Jenny; Stephan, Alexander; Zorn, Holger; Fraatz, Marco Alexander

    2018-03-14

    The basidiomycete Pleurotus sapidus (PSA) was grown in submerged cultures with molasses as substrate for the production of mycelium as a protein source for food applications. The volatilomes of the substrate, the submerged culture, and the mycelia were analyzed by gas chromatography-tandem mass spectrometry-olfactometry. For compound identification, aroma dilution analyses by means of headspace solid phase microextraction and stir bar sorptive extraction were performed via variation of the split vent flow rate. Among the most potent odorants formed by PSA were arylic compounds (e.g., p-anisaldehyde), unsaturated carbonyls (e.g., 1-octen-3-one, ( E)-2-octenal, ( E, E)-2,4-decadienal), and cyclic monoterpenoids (e.g., 3,9-epoxy- p-menth-1-ene, 3,6-dimethyl-3a,4,5,7a-tetrahydro-1-benzofuran-2(3 H)-one). Several compounds from the latter group were described for the first time in Pleurotus spp. After separation of the mycelia from the medium, the aroma compounds were mainly enriched in the culture supernatant. The sensory analysis of the mycelium correlated well with the instrumental results.

  1. Boron nitride nanotubes as novel sorbent for solid-phase microextraction of polycyclic aromatic hydrocarbons in environmental water samples.

    PubMed

    Fu, Meizhen; Xing, Hanzhu; Chen, Xiangfeng; Zhao, Rusong; Zhi, Chunyi; Wu, Chiman Lawrence

    2014-09-01

    Boron nitride nanotube (BNNT) is a novel material that shows potential ability in capturing organic pollutants. In this study, BNNTs fixed on a stainless steel fiber by a sol-gel technique were used as sorbent for solid-phase microextraction. Five polycyclic aromatic hydrocarbons with different numbers of aromatic rings were selected as target analysts. Gas chromatography coupled with tandem mass spectrometry was used for detection and quantitative determination. Under optimized conditions, the experimental results show a wide range of linearity (1 to 1,000 ng L(-1)), less than 10.1 % repeatability of relative standard deviation, and low detection limits (0.08 to 0.39 ng L(-1)). In addition, the fabricated fiber offered good thermal and chemical stability. The proposed method was successfully applied for the analysis of real water samples, and satisfactory results were obtained with relative recoveries ranging from 80.2 to 116.8 %. The results demonstrated that BNNTs could be used as sorbent for the analysis of environmental pollutants at trace levels.

  2. Direct immersion-solid phase microextraction for the determination of chlorinated pesticide residues in tomatoes by gas chromatography with an electron capture detector.

    PubMed

    Mariani, Maurizio Boccacci; Giannetti, Vanessa; Testani, Elena; Ceccarelli, Valentina

    2013-01-01

    The use of pesticides in agriculture has grown dramatically over the last decades. Environmental exposure of humans to agrochemicals is common and results in both acute and chronic health effects. In this study, direct immersion-solid phase microextraction (SPME) was coupled with electron capture detection for trace determination of 19 chlorinated pesticides in tomato samples, using a 100 pm polydimethylsiloxane fiber. The experimental parameters extraction time, extraction temperature, stirring, and salting out were evaluated and optimized. The LODs ranged from 0.5 to 8 microg/kg, and the LOQs from 5 to 30 microg/kg. A linear response was confirmed by correlation coefficients ranging from 0.97 to 0.9985. The developed method was tested by analyzing real samples purchased within the network of Italian distribution. The samples were found to be free from detectable residues of the studied pesticides. SPME has been shown to be a fast extraction technique that has several advantages such as solvent-free extraction, simplicity, and compatibility with the chromatographic analytical system.

  3. Application of headspace and direct immersion solid-phase microextraction in the analysis of organothiophosphates related to the Chemical Weapons Convention from water and complex matrices.

    PubMed

    Althoff, Marc André; Bertsch, Andreas; Metzulat, Manfred; Klapötke, Thomas M; Karaghiosoff, Konstantin L

    2017-11-01

    The successful application of headspace (HS) and direct immersion (DI) solid phase microextraction (SPME) for the unambiguous identification and characterization of a series of toxic thiophosphate esters, such as Amiton (I), from aqueous phases and complex matrices (e.g. grass and foliage) has been demonstrated. A Thermo Scientific gas chromatograph (GC) - tandem mass spectrometer (MS/MS) system with a TriPlus RSH® autosampler and a SPME tool was used to investigate the effect of different parameters that influence the extraction efficiency: e.g. pH of the sample matrix and extraction temperature. The developed methods were employed for the detection of several Amiton derivatives (Schedule II of the CWC) that are structurally closely related to each other; some of which are new and have not been reported in literature previously. In addition, a novel DI SPME method from complex matrices for the analysis of organophosphates related to the CWC was developed. The studies clearly show that DI SPME for complex matrices is superior to HS extraction and can potentially be applied to other related compounds controlled under the CWC. Copyright © 2017. Published by Elsevier B.V.

  4. Stirring-controlled solidified floating solid-liquid drop microextraction as a new solid phase-enhanced liquid-phase microextraction method by exploiting magnetic carbon nanotube-nickel hybrid.

    PubMed

    Ghazaghi, Mehri; Mousavi, Hassan Zavvar; Shirkhanloo, Hamid; Rashidi, Alimorad

    2017-01-25

    A specific technique is introduced to overcome limitations of classical solidification of floating organic drop microextraction, such as tedious and time-consuming centrifuge step and using disperser solvent, by facile and efficient participation of solid and liquid phases. In this proposed method of stirring-controlled solidified floating solid-liquid drop microextraction (SC-SF-SLDME), magnetic carbon nanotube-nickel hybrid (MNi-CNT) as a solid part of the extractors are dispersed ultrasonically in sample solution, and the procedure followed by dispersion of liquid phase (1-undecanol) through high-rate stirring and easily recollection of MNi-CNT in organic solvent droplets through hydrophobic force. With the reduction in speed of stirring, one solid-liquid drop is formed on top of the solution. MNi-CNT acts as both extractor and the coalescence helper between organic droplets for a facile recollection. MNi-CNT was prepared by spray pyrolysis of nickel oleate/toluene mixture at 1000 °C. Four tyrosine kinase inhibitors were selected as model analytes and the effecting parameters were investigated. The results confirmed that magnetic nanoadsorbent has an important role in the procedure and complete collection of dispersed solvent is not achieved in the absence of the solid phase. Also, short extraction time exhibited success of the proposed method and effect of dispersed solid/liquid phases. The limits of quantification (LOQs) for imatinib, sunitinib, erlotinib, and nilotinib were determined to be as low as 0.7, 1.7, 0.6, and 1.0 μg L -1 , respectively. The intra-day precisions (RSDs) were lower than 4.5%. Method performance was investigated by determination of mentioned tyrosine kinase inhibitors (TKIs) in human serum and cerebrospinal fluid samples with good recoveries in the range of 93-98%. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Optimization of total vaporization solid-phase microextraction (TV-SPME) for the determination of lipid profiles of Phormia regina, a forensically important blow fly species.

    PubMed

    Kranz, William; Carroll, Clinton; Dixon, Darren; Picard, Christine; Goodpaster, John

    2017-11-01

    A new method has been developed for the determination of fatty acids, sterols, and other lipids which naturally occur within pupae of the blow fly Phormia regina. The method relies upon liquid extraction in non-polar solvent, followed by derivatization using N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) w/ 1% trimethylchlorsilane (TMCS) carried out inside the sample vial. The analysis is facilitated by total vaporization solid-phase microextraction (TV-SPME), with gas chromatography-mass spectrometry (GC-MS) serving as the instrumentation for analysis. The TV-SPME delivery technique is approximately a factor of five more sensitive than traditional liquid injection, which may alleviate the need for rotary evaporation, reconstitution, collection of high performance liquid chromatography fractions, and many of the other pre-concentration steps that are commonplace in the current literature. Furthermore, the ability to derivatize the liquid extract in a single easy step while increasing sensitivity represents an improvement over current derivatization methods. The most common lipids identified in fly pupae were various saturated and unsaturated fatty acids ranging from lauric acid (12:0) to arachinoic acid (20:4), as well as cholesterol. The concentrations of myristic acid (14:0), palmitelaidic acid (16:2), and palmitoleic acid (16:1) were the most reliable indicators of the age of the pupae. Graphical abstract Blow fly pupae were extracted prior to emerging as adults. The extracts were analyzed via total vaporization solid-phase microextraction (TV-SPME), revealing a complex mixture of lipids that could be associated with the age of the insect. This information may assist in determining a post-mortum interval (PMI) in a death investigation.

  6. Solid-phase microextraction with temperature-programmed desorption for the analysis of iodination disinfection byproducts.

    PubMed

    Frazey, P A; Barkley, R M; Sievers, R E

    1998-02-01

    An analytical approach for the determination of chlorination and iodination disinfection byproducts based on solid-phase microextraction (SPME) was developed. Solid-phase microextraction presents a simple, rapid, sensitive, and solvent-free approach to sample preparation in which analytes in either air or water matrixes are extracted into the polymeric coating of an optical fiber. Analytes are subsequently thermally desorbed in the injection port of a gas chromatograph for separation, detection, and quantitation. Thermal degradation of iodoform was observed during desorption from a polyacrylate fiber in initial GC/MS and GC/ECD experiments. Experiments were designed to determine SPME conditions that would allow quantification without significant degradation of analytes. Isothermal and temperature-programmed thermal desorptions were evaluated for efficacy in transferring analytes with wide-ranging volatilities and thermal stabilities into chromatographic analysis columns. A temperature-programmed desorption (TPD) (120-200 degrees C at 5 degrees C/min with an on-column injection port or 150-200 degrees C at 25 degrees C/min with a split/splitless injection port) was able to efficiently remove analytes with wide-ranging volatilities without causing thermal degradation. The SPME-TPD method was linear over 2-3 orders of magnitude with an electron capture detector and detection limits were in the submicrogram per liter range. Precision and detection limits for selected trihalomethanes were comparable to those of EPA method 551. Extraction efficiencies were not affected by the presence of 10 mg/L soap, 15 mg/L sodium iodide, and 6000 mg/L sodium thiosulfate. The SPME-TPD technique was applied to the determination of iodination disinfection byproducts from individual precursor compounds using GC/MS and to the quantitation of iodoform at trace levels in a water recycle system using GC/ECD.

  7. Direct synthesis of nitrogen-doped graphene on platinum wire as a new fiber coating method for the solid-phase microextraction of BXes in water samples: Comparison of headspace and cold-fiber headspace modes.

    PubMed

    Memarian, Elham; Hosseiny Davarani, Saied Saeed; Nojavan, Saeed; Movahed, Siyavash Kazemi

    2016-09-07

    In this work, a new solid-phase microextraction fiber was prepared based on nitrogen-doped graphene (N-doped G). Moreover, a new strategy was proposed to solve problems dealt in direct coating of N-doped G. For this purpose, first, Graphene oxide (GO) was coated on Pt wire by electrophoretic deposition method. Then, chemical reduction of coated GO to N-doped G was accomplished by hydrazine and NH3. The prepared fiber showed good mechanical and thermal stabilities. The obtained fiber was used in two different modes (conventional headspace solid-phase microextraction and cold-fiber headspace solid-phase microextraction (CF-HS-SPME)). Both modes were optimized and applied for the extraction of benzene and xylenes from different aqueous samples. All effective parameters including extraction time, salt content, stirring rate, and desorption time were optimized. The optimized CF-HS-SPME combined with GC-FID showed good limit of detections (LODs) (0.3-2.3 μg/L), limit of quantifications (LOQs) (1.0-7.0 μg/L) and linear ranges (1.0-5000 μg/L). The developed method was applied for the analysis of benzene and xylenes in rainwater and some wastewater samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Headspace solid-phase microextraction coupled to gas chromatography for the analysis of aldehydes in edible oils.

    PubMed

    Ma, Chunhua; Ji, Jiaojiao; Tan, Connieal; Chen, Dongmei; Luo, Feng; Wang, Yiru; Chen, Xi

    2014-03-01

    Oxidation has important effects on the quality of edible oils. In particular, the generation of aldehydes produced by the oxidation of oils is one of the deteriorative factors to their quality. The aim of this study was to develop a method to determine the aldehydes as lipid oxidation markers in edible oils. Seven aldehydes generated from lipid oxidation were studied using headspace solid-phase microextraction coupled to gas chromatography with a flame ionization detector. The extraction efficiency of five commercial fibers was investigated and the influence of extraction temperature, extraction time, desorption temperature, and desorption time were optimized. The best result was obtained with 85 μm carboxen/polydimethylsiloxane, extraction at 50 °C for 15 min and desorption in the gas chromatography injector at 250 °C for 2 min. Under the optimized conditions, the content of hexanal was the highest of the seven aldehydes in all edible oils. The limits of detection for hexanal in the three oils were found to range from 4.6 to 10.2 ng L(-1). The reproducibility of the method was evaluated and the relative standard deviations were less than 8.9%. This developed approach was successfully applied to analyze hexanal in peanut oil, soy oil, and olive oil samples, and these results were compared with those obtained using the thiobarbituric acid-reactive substances (TBARs) method. © 2013 The Authors. Published by Elsevier B.V. All rights reserved.

  9. Novel strategies for sample preparation in forensic toxicology.

    PubMed

    Samanidou, Victoria; Kovatsi, Leda; Fragou, Domniki; Rentifis, Konstantinos

    2011-09-01

    This paper provides a review of novel strategies for sample preparation in forensic toxicology. The review initially outlines the principle of each technique, followed by sections addressing each class of abused drugs separately. The novel strategies currently reviewed focus on the preparation of various biological samples for the subsequent determination of opiates, benzodiazepines, amphetamines, cocaine, hallucinogens, tricyclic antidepressants, antipsychotics and cannabinoids. According to our experience, these analytes are the most frequently responsible for intoxications in Greece. The applications of techniques such as disposable pipette extraction, microextraction by packed sorbent, matrix solid-phase dispersion, solid-phase microextraction, polymer monolith microextraction, stir bar sorptive extraction and others, which are rapidly gaining acceptance in the field of toxicology, are currently reviewed.

  10. Solid Phase Microextraction and Related Techniques for Drugs in Biological Samples

    PubMed Central

    Moein, Mohammad Mahdi; Said, Rana; Bassyouni, Fatma

    2014-01-01

    In drug discovery and development, the quantification of drugs in biological samples is an important task for the determination of the physiological performance of the investigated drugs. After sampling, the next step in the analytical process is sample preparation. Because of the low concentration levels of drug in plasma and the variety of the metabolites, the selected extraction technique should be virtually exhaustive. Recent developments of sample handling techniques are directed, from one side, toward automatization and online coupling of sample preparation units. The primary objective of this review is to present the recent developments in microextraction sample preparation methods for analysis of drugs in biological fluids. Microextraction techniques allow for less consumption of solvent, reagents, and packing materials, and small sample volumes can be used. In this review the use of solid phase microextraction (SPME), microextraction in packed sorbent (MEPS), and stir-bar sorbtive extraction (SBSE) in drug analysis will be discussed. In addition, the use of new sorbents such as monoliths and molecularly imprinted polymers will be presented. PMID:24688797

  11. Recent developments and future trends in solid phase microextraction techniques towards green analytical chemistry.

    PubMed

    Spietelun, Agata; Marcinkowski, Łukasz; de la Guardia, Miguel; Namieśnik, Jacek

    2013-12-20

    Solid phase microextraction find increasing applications in the sample preparation step before chromatographic determination of analytes in samples with a complex composition. These techniques allow for integrating several operations, such as sample collection, extraction, analyte enrichment above the detection limit of a given measuring instrument and the isolation of analytes from sample matrix. In this work the information about novel methodological and instrumental solutions in relation to different variants of solid phase extraction techniques, solid-phase microextraction (SPME), stir bar sorptive extraction (SBSE) and magnetic solid phase extraction (MSPE) is presented, including practical applications of these techniques and a critical discussion about their advantages and disadvantages. The proposed solutions fulfill the requirements resulting from the concept of sustainable development, and specifically from the implementation of green chemistry principles in analytical laboratories. Therefore, particular attention was paid to the description of possible uses of novel, selective stationary phases in extraction techniques, inter alia, polymeric ionic liquids, carbon nanotubes, and silica- and carbon-based sorbents. The methodological solutions, together with properly matched sampling devices for collecting analytes from samples with varying matrix composition, enable us to reduce the number of errors during the sample preparation prior to chromatographic analysis as well as to limit the negative impact of this analytical step on the natural environment and the health of laboratory employees. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Ionic-liquid-based dispersive liquid-liquid microextraction combined with magnetic solid-phase extraction for the determination of aflatoxins B1 , B2 , G1 , and G2 in animal feeds by high-performance liquid chromatography with fluorescence detection.

    PubMed

    Zhao, Jiao; Zhu, Yan; Jiao, Yang; Ning, Jinyan; Yang, Yaling

    2016-10-01

    A novel two-step extraction technique combining ionic-liquid-based dispersive liquid-liquid microextraction with magnetic solid-phase extraction was developed for the preconcentration and separation of aflatoxins in animal feedstuffs before high-performance liquid chromatography coupled with fluorescence detection. In this work, ionic liquid 1-octyl-3-methylimidazolium hexafluorophosphate was used as the extractant in dispersive liquid-liquid microextraction, and hydrophobic pelargonic acid modified Fe 3 O 4 magnetic nanoparticles as an efficient adsorbent were applied to retrieve the aflatoxins-containing ionic liquid. Notably, the target of magnetic nanoparticles was the ionic liquid rather than the aflatoxins. Because of the rapid mass transfer associated with the dispersive liquid-liquid microextraction and magnetic solid phase steps, fast extraction could be achieved. The main parameters affecting the extraction recoveries of aflatoxins were investigated and optimized. Under the optimum conditions, vortexing at 2500 rpm for 1 min in the dispersive liquid-liquid microextraction and magnetic solid-phase extraction and then desorption by sonication for 2 min with acetonitrile as eluent. The recoveries were 90.3-103.7% with relative standard deviations of 3.2-6.4%. Good linearity was observed with correlation coefficients ranged from 0.9986 to 0.9995. The detection limits were 0.632, 0.087, 0.422 and 0.146 ng/mL for aflatoxins B 1 , B2, G1, and G2, respectively. The results were also compared with the pretreatment method carried out by conventional immunoaffinity columns. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Development of water-phase derivatization followed by solid-phase microextraction and gas chromatography/mass spectrometry for fast determination of valproic acid in human plasma.

    PubMed

    Deng, Chunhui; Li, Ning; Ji, Jie; Yang, Bei; Duan, Gengli; Zhang, Xiangmin

    2006-01-01

    In this study, a simple, rapid, and sensitive method was developed and validated for the quantification of valproic acid (VPA), an antiepileptic drug, in human plasma, which was based on water-phase derivatization followed by headspace solid-phase microextraction (HS-SPME) and gas chromatography/mass spectrometry (GC/MS). In the proposed method, VPA in plasma was rapidly derivatized with a mixture of isobutyl chloroformate, ethanol and pyridine under mild conditions (room temperature, aqueous medium), and the VPA ethyl ester formed was headspace-extracted and simultaneously concentrated using the SPME technique. Finally, the analyte extracted on SPME fiber was analyzed by GC/MS. The experimental parameters and method validations were studied. The optimal conditions were obtained: PDMS fiber, stirring rate of 1100 rpm, sample temperature of 80 degrees C, extraction time of 20 min, NaCl concentration of 30%. The proposed method had a limit of quantification (0.3 microg/mL), good recovery (89-97%) and precision (RSD value less than 10%). Because the proposed method combined a rapid water-phase derivatization with a fast, simple and solvent-free sample extraction and concentration technique of SPME, the sample preparation time was less than 25 min. This much shortens the whole analysis time of VPA in plasma. The validated method has been successfully used to analyze VPA in human plasma samples for application in pharmacokinetic studies. All these results show that water-phase derivatization followed by HS-SPME and GC/MS is an alternative and powerful method for fast determination of VPA in biological fluids. Copyright 2006 John Wiley & Sons, Ltd.

  14. Advances in covalent organic frameworks in separation science.

    PubMed

    Qian, Hai-Long; Yang, Cheng-Xiong; Wang, Wen-Long; Yang, Cheng; Yan, Xiu-Ping

    2018-03-23

    Covalent organic frameworks (COFs) are a new class of multifunctional crystalline organic polymer constructed with organic monomers via robust covalent bonds. The unique properties such as convenient modification, low densities, large specific surface areas, good stability and permanent porosity make COFs great potential in separation science. This review shows the state-of-the art for the application of COFs and their composites in analytical separation science. COFs and their composites have been explored as promising sorbents for solid phase extraction, potential coatings for solid phase microextraction, and novel stationary phases for gas chromatography, high-performance liquid chromatography and capillary electrochromatography. The prospects of COFs for separation science are also presented, which can offer an outlook and reference for further study on the applications of COFs. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Development of a solid-phase microextraction gas chromatography with microelectron-capture detection method for the determination of 5-bromo-5-nitro-1,3-dioxane in rinse-off cosmetics.

    PubMed

    Fernandez-Alvarez, Maria; Lamas, J Pablo; Sanchez-Prado, Lucia; Llompart, Maria; Garcia-Jares, Carmen; Lores, Marta

    2010-10-22

    5-Bromo-5-nitro-1,3-dioxane (bronidox) is a bromine-containing preservative often used in rinse-off cosmetics but also subjected to several restrictions according to the European Cosmetic Products Regulation. Thus, as a part of a quality control procedure, analytical methods for the determination of this compound in different types of cosmetics are required. In the present work, a solvent-free and simple methodology based on solid-phase microextraction (SPME) followed by gas chromatography with microelectron capture detection (GC-μECD) has been developed and validated for the determination of bronidox in cosmetic samples such as shampoos, body cleansers or facial exfoliants. As far as we know, this is the first application of SPME to this preservative. Negative matrix effects due to the complexity of the studied samples were reduced by dilution with ultrapure water. The influence of several factors on the SPME procedure such as fiber coating, extraction temperature, salt addition (NaCl) and sampling mode has been assessed by performing a 2(4)-factorial design. After optimization, the recommended procedure was established as follows: direct solid-phase microextraction (DSPME), using a PDMS/DVB coating, of 10 mL of diluted cosmetic with 20% NaCl, at room temperature, under stirring for 30 min. Using these suggested extraction conditions, linear calibration could be achieved, with limits of detection (LOD) and quantification (LOQ) well below the maximum authorized concentration (0.1%) established by the European legislation. Relative standard deviations (RSD) lower than 10% were obtained for both within a day and among days precision. The method was applied to diverse types of formulations spiked with bronidox at different concentration levels (0.008-0.10%); these samples were quantified by external calibration and satisfactory recoveries (≥ 70%) were obtained in all cases. Finally, the SPME-GC-μECD methodology was applied to the analysis of several cosmetics labeled or not as containing bronidox. The presence of this preservative in some of these samples was confirmed by GC-MS. Copyright © 2010 Elsevier B.V. All rights reserved.

  16. Demonstration and Evaluation of Solid Phase Microextraction for the Assessment of Bioavailability and Contaminant Mobility. ESTCP Cost and Performance Report

    DTIC Science & Technology

    2012-08-01

    subsequent chemical analysis (into acetonitrile for high-performance liquid chromatography [ HPLC ] analysis or hexane for gas chromatography [GC... analysis ) is rapid and complete. In this work, PAHs were analyzed by Waters 2795 HPLC with fluorescent detection (USEPA Method 8310) and PCBs were...detection limits by direct water injection versus SPME with PDMS and coefficient of variation and correlation coefficient for SPME. Analysis by HPLC

  17. Insights on beer volatile profile: Optimization of solid-phase microextraction procedure taking advantage of the comprehensive two-dimensional gas chromatography structured separation.

    PubMed

    Martins, Cátia; Brandão, Tiago; Almeida, Adelaide; Rocha, Sílvia M

    2015-06-01

    The aroma profile of beer is crucial for its quality and consumer acceptance, which is modu-lated by a network of variables. The main goal of this study was to optimize solid-phase microextraction experimental parameters (fiber coating, extraction temperature, and time), taking advantage of the comprehensive two-dimensional gas chromatography structured separation. As far as we know, it is the first time that this approach was used to the untargeted and comprehensive study of the beer volatile profile. Decarbonation is a critical sample preparation step, and two conditions were tested: static and under ultrasonic treatment, and the static condition was selected. Considering the conditions that promoted the highest extraction efficiency, the following parameters were selected: poly(dimethylsiloxane)/divinylbenzene fiber coating, at 40ºC, using 10 min of pre-equilibrium followed by 30 min of extraction. Around 700-800 compounds per sample were detected, corresponding to the beer volatile profile. An exploratory application was performed with commercial beers, using a set of 32 compounds with reported impact on beer aroma, in which different patterns can be observed through the structured chromatogram. In summary, the obtained results emphasize the potential of this methodology to allow an in-depth study of volatile molecular composition of beer. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. A direct immersion solid-phase microextraction gas chromatography/mass spectrometry method for the simultaneous detection of levamisole and minor cocaine congeners in hair samples from chronic abusers.

    PubMed

    Fucci, Nadia; Gambelunghe, Cristiana; Aroni, Kyriaki; Rossi, Riccardo

    2014-12-01

    Because levamisole has been increasingly found as a component of illicit drugs, a robust method to detect its presence in hair samples is needed. However, no systematic research on the detection of levamisole in hair samples has been published. The method presented here uses direct immersion solid-phase microextraction coupled with gas chromatography and mass spectrometry (DI-SPME-GC/MS) to detect levamisole and minor cocaine congeners in hair samples using a single-extraction method. Fifty hair samples taken in the last 4 years were obtained from cocaine abusers, along with controls taken from drug-free volunteers. Sampling was performed using direct immersion with a 30-μm polydimethylsiloxane fused silica/stainless steel fiber. Calibration curves were prepared by adding known amounts of analytes and deuterated internal standards to the hair samples taken from drug-free volunteers. This study focused on the adulterant levamisole and some minor cocaine congeners (tropococaine, norcocaine, and cocaethylene). Levamisole was detected in 38% of the hair samples analyzed; its concentration ranged from 0.2 to 0.8 ng/mg. The limit of quantification and limit of detection for levamisole, tropococaine, norcocaine, and cocaine were 0.2 and 0.1 ng/mg, respectively. DI-SPME-GC/MS is a sensitive and specific method to detect the presence of levamisole and cocaine congeners in hair samples.

  19. Optimization of a sensitive method for the determination of nitro musk fragrances in waters by solid-phase microextraction and gas chromatography with micro electron capture detection using factorial experimental design.

    PubMed

    Polo, Maria; Garcia-Jares, Carmen; Llompart, Maria; Cela, Rafael

    2007-08-01

    A solid-phase microextraction method (SPME) followed by gas chromatography with micro electron capture detection for determining trace levels of nitro musk fragrances in residual waters was optimized. Four nitro musks, musk xylene, musk moskene, musk tibetene and musk ketone, were selected for the optimization of the method. Factors affecting the extraction process were studied using a multivariate approach. Two extraction modes (direct SPME and headspace SPME) were tried at different extraction temperatures using two fiber coatings [Carboxen-polydimethylsiloxane (CAR/PDMS) and polydimethylsiloxane-divinylbenzene (PDMS/DVB)] selected among five commercial tested fibers. Sample agitation and the salting-out effect were also factors studied. The main effects and interactions between the factors were studied for all the target compounds. An extraction temperature of 100 degrees C and sampling the headspace over the sample, using either CAR/PDMS or PDMS/DVB as fiber coatings, were found to be the experimental conditions that led to a more effective extraction. High sensitivity, with detection limits in the low nanogram per liter range, and good linearity and repeatability were achieved for all nitro musks. Since the method proposed performed well for real samples, it was applied to different water samples, including wastewater and sewage, in which some of the target compounds (musk xylene and musk ketone) were detected and quantified.

  20. Solid-phase microextraction-gas chromatography-mass spectrometry for the analysis of selective serotonin reuptake inhibitors in environmental water.

    PubMed

    Lamas, J Pablo; Salgado-Petinal, Carmen; García-Jares, Carmen; Llompart, María; Cela, Rafael; Gómez, Mariano

    2004-08-13

    The continuous contamination of surface waters by pharmaceuticals is of most environmental concern. Selective serotonin reuptake inhibitors (SSRIs) are drugs currently prescribed for the treatment of depressions and other psychiatric disorders and then, they are among the pharmaceuticals that can occur in environmental waters. Solid-phase microextraction (SPME) coupled to gas chromatography-mass spectrometry has been applied to the extraction of five SSRIs--venlafaxine, fluvoxamine, fluoxetine, citalopram and sertraline--from water samples. Some of the analytes were not efficiently extracted as underivatized compounds and so, an in situ acetylation step was introduced in the sample preparation procedure. Different parameters affecting extraction efficiency such as extraction mode, fiber coating and temperature were studied. A mixed-level fractional factorial design was also performed to simultaneously study the influence of other five experimental factors. Finally, a method based on direct SPME at 100 degrees C using polydimethylsiloxane-divinylbenzene fibers is proposed. The performance of the method was evaluated, showing good linearity and precision. The detection limits were in the sub-ng/mL level. Practical applicability was demonstrated through the analysis of real samples. Recoveries obtained for river water and wastewater samples were satisfactory in all cases. An important aspect of the proposed method is that no matrix effects were observed. Two of the target compounds, venlafaxine and citalopram, were detected and quantified in a sewage water sample.

  1. Simultaneous determination of 76 micropollutants in water samples by headspace solid phase microextraction and gas chromatography-mass spectrometry.

    PubMed

    Martínez, C; Ramírez, N; Gómez, V; Pocurull, E; Borrull, F

    2013-11-15

    This study focuses on the development of an analytical method based on headspace solid phase microextraction (HS-SPME) and gas chromatography-mass spectrometry (GC-MS) for the simultaneous determination of 76 micropollutants in water samples. The selected micropollutants include volatile organic compounds (VOCs) (e.g. chlorobenzenes, chloroalkanes), endocrine disrupting compounds (EDCs) (e.g. bisphenol A and tributyl phosphate), odour compounds (e.g. limonene, phenol), fragrance allergens (e.g. geraniol, eugenol) and some pesticides (e.g. heptachlor, terbutryn). The experimental conditions affecting their extraction, such as the type of fibre, temperature and time of extraction, sample volume and ionic strength of the samples were optimized using HS-SPME. The method showed good linear range, reproducibility between days, repeatability and low detection limits (at ng L(-1) levels). The validated method has been applied to determine the target organic micropollutants in aqueous samples from different experimental research units of surface water, sea water, waste water and those effluents of advance membrane treatments. The optimized method showed good performance in the different types of samples studied. The analysis revealed the presence of several micropollutants at concentrations between 20 and 5000 μg L(-1), such as ethylbenzene, o-xylene, p-isopropilbenzene, D-limonene, citral and isoeugenol, due to the fact that these species are commonly used in domestic and industrial applications. © 2013 Elsevier B.V. All rights reserved.

  2. Determination of different recreational drugs in sweat by headspace solid-phase microextraction gas chromatography mass spectrometry (HS-SPME GC/MS): Application to drugged drivers.

    PubMed

    Gentili, Stefano; Mortali, Claudia; Mastrobattista, Luisa; Berretta, Paolo; Zaami, Simona

    2016-09-10

    A procedure based on headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography/mass spectrometry (GC/MS) has been developed for the determination of most commonly used drugs of abuse in sweat of drivers stopped during roadside controls. DrugWipe 5A sweat screening device was used to collect sweat by a specific pad rubbed gently over forehead skin surface. The procedure involved an acid hydrolysis, a HS-SPME extraction for drugs of abuse but Δ(9)-tetrahydrocannabinol, which was directly extracted in alkaline medium HS-SPME conditions, a GC separation of analytes by a capillary column and MS detection by electron impact ionisation. The method was linear from the limit of quantification (LOQ) to 50ng drug per pad (r(2)≥0.99), with an intra- and inter-assay precision and accuracy always less than 15% and an analytical recovery between 95.1% and 102.8%, depending on the considered analyte. Using the validated method, sweat from 60 apparently intoxicated drivers were found positive to one or more drugs of abuse, showing sweat patches testing as a viable economic and simple alternative to conventional (blood and/or urine) and non conventional (oral fluid) testing of drugs of abuse in drugged drivers. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Barley husk carbon as the fiber coating for the solid-phase microextraction of twelve pesticides in vegetables prior to gas chromatography-mass spectrometric detection.

    PubMed

    Liang, Weiqian; Wang, Juntao; Zang, Xiaohuan; Dong, Wenhuan; Wang, Chun; Wang, Zhi

    2017-03-31

    In this work, a barley husk biomaterial was successfully carbonized by hydrothermal method. The carbon had a high specific surface area and good stability. It was coated onto a stainless steel wire through sol-gel technique to prepare a solid-phase microextraction fiber for the extraction of trace levels of twelve pesticides (tsumacide, fenobucarb, indoxacarb, diethofencarb, thimet, terbufos, malathion, thiamethoxam, imidacloprid, buprofezin, acetamiprid, thiamethoxam) from vegetable samples prior to gas chromatography-mass spectrometric (GC-MS) detection. The main experimental parameters that could influence the extraction efficiency such as extraction time, extraction temperature, sample pH, sample salinity, stirring rate, desorption temperature and desorption time, were investigated. Under the optimized conditions, the linearity was observed in the range of 0.2-75.0μgkg -1 for tomato samples, and 0.3-60.0μgkg -1 for cucumber samples, with the correlation coefficients (r) ranging from 0.9959 to 0.9983. The limits of detection of the method were 0.01-0.05μgkg -1 for tomato samples, and 0.03-0.10μgkg -1 for cucumber samples. The recoveries of the analytes for the method from spiked samples were in the range of 76%-104%, and the precision, expressed as the relative standard deviations, was less than 12%. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Method of analysis and quality-assurance practices by the U.S. Geological Survey Organic Geochemistry Research Group; determination of geosmin and methylisoborneol in water using solid-phase microextraction and gas chromatography/mass spectrometry

    USGS Publications Warehouse

    Zimmerman, L.R.; Ziegler, A.C.; Thurman, E.M.

    2002-01-01

    A method for the determination of two common odor-causing compounds in water, geosmin and 2-methylisoborneol, was modified and verified by the U.S. Geological Survey's Organic Geochemistry Research Group in Lawrence, Kansas. The optimized method involves the extraction of odor-causing compounds from filtered water samples using a divinylbenzene-carboxen-polydimethylsiloxane cross-link coated solid-phase microextraction (SPME) fiber. Detection of the compounds is accomplished using capillary-column gas chromatography/mass spectrometry (GC/MS). Precision and accuracy were demonstrated using reagent-water, surface-water, and ground-water samples. The mean accuracies as percentages of the true compound concentrations from water samples spiked at 10 and 35 nanograms per liter ranged from 60 to 123 percent for geosmin and from 90 to 96 percent for 2-methylisoborneol. Method detection limits were 1.9 nanograms per liter for geosmin and 2.0 nanograms per liter for 2-methylisoborneol in 45-milliliter samples. Typically, concentrations of 30 and 10 nanograms per liter of geosmin and 2-methylisoborneol, respectively, can be detected by the general public. The calibration range for the method is equivalent to concentrations from 5 to 100 nanograms per liter without dilution. The method is valuable for acquiring information about the production and fate of these odor-causing compounds in water.

  5. Doping of three-dimensional porous carbon nanotube-graphene-ionic liquid composite into polyaniline for the headspace solid-phase microextraction and gas chromatography determination of alcohols.

    PubMed

    Li, Lulu; Wu, Mian; Feng, Yingying; Zhao, Faqiong; Zeng, Baizhao

    2016-12-15

    In this work, ionic liquid (IL, i.e. 1-hydroxyethyl-3-methylimidazolium tetrafluoroborate), carboxyl multiwall carbon nanotubes (MWCNTs) and reduced graphene oxide (rGO) were used to prepare three-dimensional porous material (MWCNTs-rGO-IL) by one-step self-assembly, then it was co-electrodeposited with polyaniline (PANI) on stainless steel wires by cyclic voltammetry. The resulting coating (PANI-MWCNTs-rGO-IL) was characterized by using FT-IR and scanning electron microscopy etc, and it showed porous structure and had high thermal stability. Furthermore, it was found to be very suitable for the headspace solid-phase microextraction of alcohols (i.e. octanol, nonanol, geraniol, decanol, undecanol and dodecanol). By coupling with gas chromatography, wide linear ranges and low limits of detection (i.e. 2.2-28.3 ng L -1 ) were obtained for the alcohols. The coating also presented good repeatability and reproducibility; the relative standard deviations for intra-fiber and fiber-to-fiber were less than 5.6% (n = 5) and 7.0% (n = 5) respectively. In addition, the proposed method was successfully applied to the determination of alcohols in tea drinks, and the recoveries for standards added were 85.6-114%. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Italian and Spanish commercial tomato sauces for pasta dressing: study of sensory and head-space profiles by Flash Profiling and solid-phase microextraction-gas chomatography-mass spectrometry.

    PubMed

    Bendini, Alessandra; Vallverdú-Queralt, Anna; Valli, Enrico; Palagano, Rosa; Lamuela-Raventos, Rosa Maria; Toschi, Tullia Gallina

    2017-08-01

    The sensory and head-space profiles of Italian and Spanish commercial tomato sauces were investigated. The Flash Profiling method was used to evaluate sensory characteristics. Samples within each set were ranked according to selected descriptors. One hundred volatile compounds were identified by solid-phase microextraction-gas chomatography-mass spectrometry. For Italian samples, the sensory notes of basil/aromatic herbs, acid and cooked tomato were among those perceived most by the assessors, whereas, in Spanish samples, the sensory attributes of garlic/onion and onion/sweet pepper and, in Italian samples, cooked tomato were among those found most frequently. Data were elaborated using multivariate statistical approaches and interesting correlations were observed among the different sensory attributes and related volatile compounds. Spanish samples were characterized by the highest content of volatiles linked to the thermal treatment of tomatoes and to raw and sautéed garlic and onion, whereas the Italian samples were characterized by terpenic compounds typical of basil and volatile molecules derived from fresh tomato. These results confirm the influence of both formulation and production processes on the aromatic profile (sensory attributes and volatile compounds) of tomato products, which is probably related to the different eating habits and culinary traditions in Italy and Spain. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  7. Determination of cannabinoids in hemp food products by use of headspace solid-phase microextraction and gas chromatography-mass spectrometry.

    PubMed

    Lachenmeier, Dirk W; Kroener, Lars; Musshoff, Frank; Madea, Burkhard

    2004-01-01

    A fully automated procedure using alkaline hydrolysis and headspace solid-phase microextraction (HS-SPME), followed by on-fiber derivatization and gas chromatographic-mass spectrometric (GC-MS) detection has been developed for determination of cannabinoids in hemp food samples. After addition of a deuterated internal standard, the sample was hydrolyzed with sodium hydroxide and submitted to direct HS-SPME. After absorption of analytes for on-fiber derivatization, the fiber was placed directly into the headspace of a second vial containing N-methyl- N-trimethylsilyltrifluoroacetamide (MSTFA), before GC-MS analysis. Linearity was good for Delta(9)-tetrahydrocannabinol (THC), cannabidiol, and cannabinol; regression coefficients were greater than 0.99. Depending on the characteristics of the matrix the detection limits obtained ranged between 0.01 and 0.17 mg kg(-1) and the precision between 0.4 and 11.8%. In comparison with conventional liquid-liquid extraction this automated HS-SPME-GC-MS procedure is substantially faster. It is easy to perform, solvent-free, and sample quantities are minimal, yet it maintains the same sensitivity and reproducibility. The applicability was demonstrated by analysis of 30 hemp food samples. Cannabinoids were detected in all of the samples and it was possible to differentiate between drug-type and fiber-type Cannabis sativa L. In comparison with other studies relatively low THC concentrations between 0.01 and 15.53 mg kg(-1) were determined.

  8. Recovery of phosphonate surface contaminants from glass using a simple vacuum extractor with a solid-phase microextraction fiber.

    PubMed

    Groenewold, Gary S; Scott, Jill R; Rae, Catherine

    2011-07-04

    Recovery of chemical contaminants from fixed surfaces for analysis can be challenging, particularly if it is not possible to acquire a solid sample to be taken to the laboratory. A simple device is described that collects semi-volatile organic compounds from fixed surfaces by creating an enclosed volume over the surface, then generating a modest vacuum. A solid-phase microextraction (SPME) fiber is then inserted into the evacuated volume where it functions to sorb volatilized organic contaminants. The device is based on a syringe modified with a seal that is used to create the vacuum, with a perforable plunger through which the SPME fiber is inserted. The reduced pressure speeds partitioning of the semi-volatile compounds into the gas phase and reduces the boundary layer around the SPME fiber, which enables a fraction of the volatilized organics to partition into the SPME fiber. After sample collection, the SPME fiber is analyzed using conventional gas chromatography/mass spectrometry. The methodology has been used to collect organophosphorus compounds from glass surfaces, to provide a simple test for the functionality of the devices. Thirty minute sampling times (ΔT(vac)) resulted in fractional recovery efficiencies that ranged from 10(-3) to >10(-2), and in absolute terms, collection of low nanograms was demonstrated. Fractional recovery values were positively correlated to the vapor pressure of the compounds being sampled. Fractional recovery also increased with increasing ΔT(vac) and displayed a roughly logarithmic profile, indicating that an operational equilibrium is being approached. Fractional recovery decreased with increasing time between exposure and sampling; however, recordable quantities of the phosphonates could be collected three weeks after exposure. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. Metal-organic frameworks for analytical chemistry: from sample collection to chromatographic separation.

    PubMed

    Gu, Zhi-Yuan; Yang, Cheng-Xiong; Chang, Na; Yan, Xiu-Ping

    2012-05-15

    In modern analytical chemistry researchers pursue novel materials to meet analytical challenges such as improvements in sensitivity, selectivity, and detection limit. Metal-organic frameworks (MOFs) are an emerging class of microporous materials, and their unusual properties such as high surface area, good thermal stability, uniform structured nanoscale cavities, and the availability of in-pore functionality and outer-surface modification are attractive for diverse analytical applications. This Account summarizes our research on the analytical applications of MOFs ranging from sampling to chromatographic separation. MOFs have been either directly used or engineered to meet the demands of various analytical applications. Bulk MOFs with microsized crystals are convenient sorbents for direct application to in-field sampling and solid-phase extraction. Quartz tubes packed with MOF-5 have shown excellent stability, adsorption efficiency, and reproducibility for in-field sampling and trapping of atmospheric formaldehyde. The 2D copper(II) isonicotinate packed microcolumn has demonstrated large enhancement factors and good shape- and size-selectivity when applied to on-line solid-phase extraction of polycyclic aromatic hydrocarbons in water samples. We have explored the molecular sieving effect of MOFs for the efficient enrichment of peptides with simultaneous exclusion of proteins from biological fluids. These results show promise for the future of MOFs in peptidomics research. Moreover, nanosized MOFs and engineered thin films of MOFs are promising materials as novel coatings for solid-phase microextraction. We have developed an in situ hydrothermal growth approach to fabricate thin films of MOF-199 on etched stainless steel wire for solid-phase microextraction of volatile benzene homologues with large enhancement factors and wide linearity. Their high thermal stability and easy-to-engineer nanocrystals make MOFs attractive as new stationary phases to fabricate MOF-coated capillaries for high-resolution gas chromatography (GC). We have explored a dynamic coating approach to fabricate a MOF-coated capillary for the GC separation of important raw chemicals and persistent organic pollutants with high resolution and excellent selectivity. We have combined a MOF-coated fiber for solid-phase microextraction with a MOF-coated capillary for GC separation, which provides an effective MOF-based tandem molecular sieve platform for selective microextraction and high-resolution GC separation of target analytes in complex samples. Microsized MOFs with good solvent stability are attractive stationary phases for high-performance liquid chromatography (HPLC). These materials have shown high resolution and good selectivity and reproducibility in both the normal-phase HPLC separation of fullerenes and substituted aromatics on MIL-101 packed columns and position isomers on a MIL-53(Al) packed column and the reversed-phase HPLC separation of a wide range of analytes from nonpolar to polar and acidic to basic solutes. Despite the above achievements, further exploration of MOFs in analytical chemistry is needed. Especially, analytical application-oriented engineering of MOFs is imperative for specific applications.

  10. Electromembrane Surrounded Solid Phase Microextraction Followed by Injection Port Derivatization and Gas Chromatography-Flame Ionization Detector Analysis for Determination of Acidic Herbicides in Plant Tissue.

    PubMed

    Rezazadeh, Maryam; Yamini, Yadollah; Seidi, Shahram; Tahmasebi, Elham; Rezaei, Fatemeh

    2014-04-09

    Electromembrane surrounded solid phase microextraction (EM-SPME) of acidic herbicides was studied for the first time. In order to investigate the capability of this new microextraction technique to analyze acidic targets, chlorophenoxy acid (CPA) herbicides were quantified in plant tissue. 1-Octanol, was sustained in the pores of the wall of a hollow fiber and served as supported liquid membrane (SLM). Other EM-SPME related parameters, including extraction time, applied voltage, and pHs of the sample solution and the acceptor phase, were optimized using experimental design. A 20 min time frame was needed to reach the highest extraction efficiency of the analytes from a 24 mL alkaline sample solution across the organic liquid membrane and into the aqueous acceptor phase through a 50 V electrical field, and to their final adsorption on a carbonaceous anode. In addition to high sample cleanup, which made the proposed method appropriate for analysis of acidic compounds in a complicated media (plant tissue), 4.8% of 2-methyl-4-chlorophenoxyacetic acid (MCPA) and 0.6% of 2,4-dichlorophenoxyacetic acid (2,4-D) were adsorbed on the anode, resulting in suitable detection limits (less than 5 ng mL -1 ), and admissible repeatability and reproducibility (intra- and interassay precision were in the ranges of 5.2-8.5% and 8.8-12.0%, respectively). Linearity of the method was scrutinized within the ranges of 1.0-500.0 and 10.0-500.0 ng mL -1 for MCPA and 2,4-D, respectively, and coefficients of determination greater than 0.9958 were obtained. Optimal conditions of EM-SPME of the herbicides were employed for analysis of CPAs in whole wheat tissue.

  11. Headspace solid-phase microextraction coupled to comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry for the analysis of aerosol from tobacco heating product.

    PubMed

    Savareear, Benjamin; Lizak, Radoslaw; Brokl, Michał; Wright, Chris; Liu, Chuan; Focant, Jean-Francois

    2017-10-20

    A method involving headspace solid-phase microextraction (HS-SPME) and comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry (GC×GC-TOFMS) was developed and optimised to elucidate the volatile composition of the particulate phase fraction of aerosol produced by tobacco heating products (THPs). Three SPME fiber types were studied in terms of extraction capacity and precision measurements. Divinylbenzene polydimethylsiloxane appeared as the most efficient coating for these measurements. A central composite design of experiment was utilised for the optimization of the extraction conditions. Qualitative and semi-quantitative analysis of the headspace above THP aerosol condensate was carried out using optimised extraction conditions. Semi-quantitative analyses of detected constituents were performed by assuming that their relative response factors to the closest internal standard ( i t R ) were equal to 1. Using deconvoluted mass spectral data (library similarity and reverse match >750) and linear retention indices (match window of ±15 index units), 205 peaks were assigned to individual compounds, 82 of which (including 43 substances previously reported to be present in tobacco) have not been reported previously in tobacco aerosol. The major volatile fraction of the headspace contained ketones, alcohols, aldehydes, alicyclic hydrocarbons alkenes, and alkanes. The method was further applied to compare the volatiles from the particulate phase of aerosol composition of THP with that of reference cigarette smoke and showed that the THP produced a less complex chemical mixture. This new method showed good efficiency and precision for the peak areas and peak numbers from the volatile fraction of aerosol particulate phase for both THP and reference cigarettes. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. SOLID PHASE MICROEXTRACTION SAMPLING OF HIGH EXPLOSIVE RESIDUES IN THE PRESENCE OF RADIONUCLIDES AND RADIONUCLIDE SURROGATE METALS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duff, M; S Crump, S; Robert02 Ray, R

    2007-04-13

    The Federal Bureau of Investigation (FBI) Laboratory currently does not have on site facilities for handling radioactive evidentiary materials and there are no established FBI methods or procedures for decontaminating high explosive (HE) evidence while maintaining evidentiary value. One experimental method for the isolation of HE residue involves using solid phase microextraction or SPME fibers to remove residue of interest. Due to their high affinity for organics, SPME fibers should have little affinity for most metals. However, no studies have measured the affinity of radionuclides for SPME fibers. The focus of this research was to examine the affinity of dissolvedmore » radionuclide ({sup 239/240}Pu, {sup 238}U, {sup 237}Np, {sup 85}Sr, {sup 133}Ba, {sup 137}Cs, {sup 60}Co and {sup 226}Ra) and stable radionuclide surrogate metals (Sr, Co, Ir, Re, Ni, Ba, Cs, Nb, Zr, Ru, and Nd) for SPME fibers at the exposure conditions that favor the uptake of HE residues. Our results from radiochemical and mass spectrometric analyses indicate these metals have little measurable affinity for these SPME fibers during conditions that are conducive to HE residue uptake with subsequent analysis by liquid or gas phase chromatography with mass spectrometric detection.« less

  13. Headspace-Solid-Phase Microextraction-Gas Chromatography as Analytical Methodology for the Determination of Volatiles in Wild Mushrooms and Evaluation of Modifications Occurring during Storage

    PubMed Central

    Costa, Rosaria; De Grazia, Selenia; Grasso, Elisa; Trozzi, Alessandra

    2015-01-01

    Mushrooms are sources of food, medicines, and agricultural means. Not much is reported in the literature about wild species of the Mediterranean flora, although many of them are traditionally collected for human consumption. The knowledge of their chemical constituents could represent a valid tool for both taxonomic and physiological characterizations. In this work, a headspace-solid-phase microextraction (HS-SPME) method coupled with GC-MS and GC-FID was developed to evaluate the volatile profiles of ten wild mushroom species collected in South Italy. In addition, in order to evaluate the potential of this analytical methodology for true quantitation of volatiles, samples of the cultivated species Agaricus bisporus were analyzed. The choice of this mushroom was dictated by its ease of availability in the food market, due to the consistent amounts required for SPME method development. For calibration of the main volatile compounds, the standard addition method was chosen. Finally, the assessed volatile composition of A. bisporus was monitored in order to evaluate compositional changes occurring during storage, which represents a relevant issue for such a wide consumption edible product. PMID:25945282

  14. Multivariate optimization of the factors influencing the solid-phase microextraction of pyrethroid pesticides in water.

    PubMed

    Casas, Vanessa; Llompart, Maria; García-Jares, Carmen; Cela, Rafael; Dagnac, Thierry

    2006-08-18

    A method based on solid-phase microextraction (SPME) and gas chromatography with micro-electron capture detection (GC-microECD) has been optimized for the analysis of pyrethroids in water samples. The influence of parameters such as temperature, fibre coating, salting-out effect and sampling mode on the extraction efficiency has been studied by means of a mix-level factorial design, which allowed the study of main effects as well as two factor interactions. Finally, a method based on direct SPME at 50 degrees C, using polydimethylsiloxane fibre is proposed. The method showed good linearity (R2>0.995) and repeatability (RSD

  15. Solid-phase micro-extraction procedure for the determination of 1,3-dichloro-2-propanol in water by on-fibre derivatisation with bis(trimethylsilyl)trifluoroacetamide.

    PubMed

    Carro, Antonia María; González, Paula; Fajar, Noelia; Lorenzo, Rosa Antonia; Cela, Rafael

    2009-06-01

    The headspace solid-phase micro-extraction technique with on-fibre derivatisation followed by gas chromatography-tandem mass spectrometry has been evaluated for the analysis of 1,3-dichloro-2-propanol in water. An asymmetric factorial design has been performed to study the influence of five experimental factors: extraction time and temperature, derivatisation time and temperature and pH. The best extraction performance is achieved in the headspace mode, with 5 mL stirred water samples (pH 4) containing 1.3 g of NaCl, equilibrated for 30 min at 25 degrees C, using divinylbenzene-carboxen-polydimethylsiloxane as the fibre coating. On-fibre derivatisation has been used for the first time with 50 microL of bis(trimethylsilyl)trifluoroacetamide at 25 degrees C during 15 min, leading to effective yields. The proposed method provides high sensitivity, good linearity and repeatability (relative standard deviation of 5.1% for 10 ng mL(-1) and n = 5). The limits of detection and quantification were 0.4 and 1.4 ng mL(-1), respectively. Analytical recoveries obtained for different water samples were approx. 100%.

  16. Determination of polycyclic aromatic hydrocarbons in urine of coke oven workers by headspace solid phase microextraction and gas chromatography-mass spectrometry.

    PubMed

    Waidyanatha, Suramya; Zheng, Yuxin; Rappaport, Stephen M

    2003-05-06

    Polycyclic aromatic hydrocarbons (PAHs) represent a complex mixture of toxic compounds that are ubiquitous in the environment. We investigated the utility of head space-solid phase microextraction (HS-SPME) to measure the following surrogate PAHs in urine: naphthalene (NAP), phenanthrene (PHE), pyrene (PYR), and benzo(a)pyrene (BAP), representing classes of 2-, 3-, 4- and 5-ring compounds, respectively. We then applied the method to urine from 28 coke oven workers (median levels (microg/l) were: NAP=3.65, PHE=1.51, PYR=0.003, BAP not detected) and 22 controls (median (microg/l) NAP=0.859, PHE=0.062, PYR=0.001, BAP not detected). Urinary levels of NAP, PHE, and PYR were all associated with exposure category (controls, side- and bottom-workers, and top-workers) but not with smoking status. Strong correlations were observed between urinary levels of NAP, PHE, and PYR in coke-oven workers. Our results indicate that unmetabolized 2-, 3- and 4-ring PAHs can be measured in urine by HS-SPME. Such measurements can be used to investigate the uptake and metabolism of complex PAH mixtures in humans.

  17. A method to detect diphenylamine contamination of apple fruit and storages using headspace solid phase micro-extraction and gas chromatography/mass spectroscopy.

    PubMed

    Song, Jun; Forney, Charles F; Jordan, Michael A

    2014-10-01

    Analysis of headspace concentrations of diphenylamine using solid phase micro-extraction (SPME) was examined for its suitability to detect DPA contamination and off-gassing in apple (Malus domestica) fruit, storage rooms and storage materials. Four SPME fibre coatings including polydimethylsiloxane (PDMS, 100 μm), PDMS/divinylbenzene (PDMS/DVB), Polyacrylate (PA) and PDMS 7 μm were evaluated. The average limits of detection and of quantification for head space DPA ranged from 0.13 to 0.72 μg L(-1) and 0.42 to 2.35 μg L(-1), respectively. Polyacrylate was identified to be the most suitable and compatible fibre for DPA analysis in apple samples, because of its high sensitivity to DPA and low fruit volatile interferences. SPME techniques were further applied to study contamination of DPA in apples, storage rooms and packaging materials. DPA was found in the air of storage rooms containing apples that were not treated with DPA. Wood and plastic bin material, bin liners, and foam insulation all adsorbed and off-gassed DPA and could be potential sources of contamination of untreated apples. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  18. Analysis of n-alkanes at sub microgram per liter level after direct solid phase microextraction from aqueous samples.

    PubMed

    Farajzadeh, Mirali; Hatami, Mehdi

    2002-11-01

    This work describes the application of the previously presented solid phase microextraction (SPME) fiber in direct mode for sampling of C10-C20 n-alkanes from aqueous solution. The fiber has simple composition and is constructed from activated charcoal:PVC suspension in tetrahydrofuran. When the composition of the fiber was optimized that the optimum composition was 90:10 (activated charcoal:PVC) for direct mode, whereas it was 75:25 for sampling from the headspace of aqueous samples. This fiber is completely stable in contact with water. The extraction efficiency is improved in the presence of 0.1 M NaCl. The value is between 17.8-38.5% for the first extraction, which better than the efficiency of similar commercial fibers. After seven extractions, all analytes are removed from the aqueous samples nearly 100%. Single fiber repeatability and fiber-to-fiber reproducibility are good and both are less than 13% for all studied alkanes. Finally, direct mode SPME was used in the determination of n-alkanes in the range of sub microg L(-1) without any additional preconcentration procedure. Gas chromatography along with flame ionization detection were used for separation and detection of the studied analytes.

  19. Ionic liquid polymer functionalized carbon nanotubes-doped poly(3,4-ethylenedioxythiophene) for highly-efficient solid-phase microextraction of carbamate pesticides.

    PubMed

    Wu, Mian; Wang, Liying; Zeng, Baizhao; Zhao, Faqiong

    2016-04-29

    A poly(3,4-ethylenedioxythiophene)-ionic liquid polymer functionalized multiwalled carbon nanotubes (PEDOT-PIL/MWCNTs) composite solid-phase microextraction (SPME) coating was fabricated by electrodeposition. After being dipped in Nafion solution, a Nafion-modified coating was obtained. The outer layer Nafion played a crucial role in enhancing the durability and stability of the coating, thus it was robust enough for replicated extraction for at least 150 times without decrease of extraction performance. The Nafion-modified coating exhibited much higher sensitivity than commercial coatings for the direct extraction of carbamate pesticides in aqueous solutions, due to its strong hydrophobic effect and π-π affinity based enrichment. When it was used for the determination of carbamate pesticides in combination with gas chromatography-flame ionization detection, good linearity (correlation coefficients higher than 0.9981), low limits of detection (15.2-27.2 ng/L) and satisfactory precision (relative standard deviation <8.2%, n=5) were achieved. The developed method was applied to the analysis of four carbamate pesticides in apple and lettuce samples, and acceptable recoveries (i.e. 87.5-106.5%) were obtained for the standard addition. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Preparation of porous aromatic framework/ionic liquid hybrid composite coated solid-phase microextraction fibers and their application in the determination of organochlorine pesticides combined with GC-ECD detection.

    PubMed

    Wu, Mingxue; Chen, Gang; Liu, Ping; Zhou, Weihong; Jia, Qiong

    2016-01-07

    A novel hybrid material incorporating porous aromatic frameworks and an ionic liquid, 1-(triethoxy silyl)propyl-3-aminopropyl imidazole hexafluorophosphate, was prepared as solid-phase microextraction coating and employed for the extraction of organochlorine pesticides. Combining the advantages of porous aromatic frameworks and an ionic liquid, the fiber exhibited a high adsorption capacity for organochlorine pesticides. Under optimized experimental conditions, enhancement factors of 247-1696 were obtained with good linearity in the range of 1-500 μg L(-1). The detection limits and quantification limits were determined to be in the range of 0.11-0.29 μg L(-1) and 0.35-0.93 μg L(-1). The relative standard deviations for six replicates of organochlorine pesticides were in the range of 4.4%-7.2% and 5.7%-10.1% for one fiber and fiber-to-fiber, respectively. By coupling with a gas chromatography-electron capture detector, the novel fiber was successfully used for the determination of organochlorine pesticides in juice and milk samples with recoveries of 76.1%-121.3%.

  1. Determination of polychlorinated biphenyls in milk samples by saponification-solid-phase microextraction.

    PubMed

    Llompart, M; Pazos, M; Landin, P; Cela, R

    2001-12-15

    A saponification-HSSPME procedure has been developed for the extraction of PCBs from milk samples. Saponification of the samples improves the PCB extraction efficiency and allows attaining lower background. A mixed-level fractional design has been used to optimize the sample preparation process. Five variables have been considered: extraction time, agitation, kind of microextraction fiber, concentration, and volume of NaOH aqueous solution. Also the kinetic of the process has been studied with the two fibers (100-microm PDMS and 65-microm PDMS-DVB) included in this study. Analyses were performed on a gas chromatograph equipped with an electron capture detector and a gas chromatograph coupled to a mass selective detector working in MS-MS mode. The proposed method is simple and rapid, and yields high sensitivity, with detection limits below 1 ng/mL, good linearity, and reproducibility. The method has been applied to liquid milk samples with different fat content covering the whole commercial range, and it has been validated with powdered milk certified reference material.

  2. A rapid and sensitive assay of perfluorocarboxylic acids in aqueous matrices by headspace solid phase microextraction-gas chromatography-triple quadrupole mass spectrometry.

    PubMed

    Monteleone, Marcello; Naccarato, Attilio; Sindona, Giovanni; Tagarelli, Antonio

    2012-08-17

    The work aims at developing a rapid and sensitive method for the quantification of perfluorocarboxylic acids in aqueous matrices. The proposed analytical approach is based on the use of solid phase microextraction in headspace mode after a fast derivatization of the carboxylate function by propylchloroformate/propanol mixture. Several fibers were evaluated and the optimization of the parameters affecting the SPME process was carried out using a central composite design. The optimum working conditions in terms of response values were achieved by performing analysis with CAR/PDMS fiber at room temperature, without addition of NaCl, with a sample volume of 6 ml and an extraction time of 10 min. Assay of PFCAs was performed by using a gas chromatography-triple quadrupole mass spectrometry (GC-QqQ MS) system in negative chemical ionization mode with ammonia as reagent gas. An overall evaluation of all analytical parameters shows that the proposed method provides satisfactory results. In particular, the observed accuracies, ranging from 84.4% to 116.8%, and the RSD values in the range 0.4% and 14.5% confirm the effectiveness of the developed protocol in the assay of PFCAs content in aqueous matrices. Moreover, LOD and LOQ values ranging from 0.08 to 6.6 ng l(-1) and from 0.17 to 14.3 ng l(-1), respectively, can be considered very satisfactory. None of the compounds were detected in six samples of river collected in Calabria. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Quantitative Determination of Caffeine in Beverages Using a Combined SPME-GC/MS Method

    NASA Astrophysics Data System (ADS)

    Pawliszyn, Janusz; Yang, Min J.; Orton, Maureen L.

    1997-09-01

    Solid-phase microextraction (SPME) combined with gas chromatography/mass spectrometry (GC/MS) has been applied to the analysis of various caffeinated beverages. Unlike the current methods, this technique is solvent free and requires no pH adjustments. The simplicity of the SPME-GC/MS method lends itself to a good undergraduate laboratory practice. This publication describes the analytical conditions and presents the data for determination of caffeine in coffee, tea, and coke. Quantitation by isotopic dilution is also illustrated.

  4. Rapid Analysis of Chemical Warfare Agents and Their Hydrolysis Products by Desorption Electrospray Ionization Mass Spectrometry (DESI-MS)

    DTIC Science & Technology

    2009-10-01

    of chemical warfare agents in natural water samples by solid-phase microextraction. Anal. Chem., 69, 1866-72. [36] Sng , M.T. and Ng ,W.F. (1999). In...liquid phase microextraction of alkylphosphonic acids from water. J. Chromatogr. A., 1141, 151-157. [43] Lee, H.S.N., Sng , M.T., Basheer, C., and Lee

  5. Analysis of trace contaminants in hot gas streams using time-weighted average solid-phase microextraction: proof of concept.

    PubMed

    Woolcock, Patrick J; Koziel, Jacek A; Cai, Lingshuang; Johnston, Patrick A; Brown, Robert C

    2013-03-15

    Time-weighted average (TWA) passive sampling using solid-phase microextraction (SPME) and gas chromatography was investigated as a new method of collecting, identifying and quantifying contaminants in process gas streams. Unlike previous TWA-SPME techniques using the retracted fiber configuration (fiber within needle) to monitor ambient conditions or relatively stagnant gases, this method was developed for fast-moving process gas streams at temperatures approaching 300 °C. The goal was to develop a consistent and reliable method of analyzing low concentrations of contaminants in hot gas streams without performing time-consuming exhaustive extraction with a slipstream. This work in particular aims to quantify trace tar compounds found in a syngas stream generated from biomass gasification. This paper evaluates the concept of retracted SPME at high temperatures by testing the three essential requirements for TWA passive sampling: (1) zero-sink assumption, (2) consistent and reliable response by the sampling device to changing concentrations, and (3) equal concentrations in the bulk gas stream relative to the face of the fiber syringe opening. Results indicated the method can accurately predict gas stream concentrations at elevated temperatures. Evidence was also discovered to validate the existence of a second boundary layer within the fiber during the adsorption/absorption process. This limits the technique to operating within reasonable mass loadings and loading rates, established by appropriate sampling depths and times for concentrations of interest. A limit of quantification for the benzene model tar system was estimated at 0.02 g m(-3) (8 ppm) with a limit of detection of 0.5 mg m(-3) (200 ppb). Using the appropriate conditions, the technique was applied to a pilot-scale fluidized-bed gasifier to verify its feasibility. Results from this test were in good agreement with literature and prior pilot plant operation, indicating the new method can measure low concentrations of tar in gasification streams. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. The current role of on-line extraction approaches in clinical and forensic toxicology.

    PubMed

    Mueller, Daniel M

    2014-08-01

    In today's clinical and forensic toxicological laboratories, automation is of interest because of its ability to optimize processes, to reduce manual workload and handling errors and to minimize exposition to potentially infectious samples. Extraction is usually the most time-consuming step; therefore, automation of this step is reasonable. Currently, from the field of clinical and forensic toxicology, methods using the following on-line extraction techniques have been published: on-line solid-phase extraction, turbulent flow chromatography, solid-phase microextraction, microextraction by packed sorbent, single-drop microextraction and on-line desorption of dried blood spots. Most of these published methods are either single-analyte or multicomponent procedures; methods intended for systematic toxicological analysis are relatively scarce. However, the use of on-line extraction will certainly increase in the near future.

  7. Aroma characterization of chinese rice wine by gas chromatography-olfactometry, chemical quantitative analysis, and aroma reconstitution.

    PubMed

    Chen, Shuang; Xu, Yan; Qian, Michael C

    2013-11-27

    The aroma profile of Chinese rice wine was investigated in this study. The volatile compounds in a traditional Chinese rice wine were extracted using Lichrolut EN and further separated by silica gel normal phase chromatography. Seventy-three aroma-active compounds were identified by gas chromatography-olfactometry (GC-O) and gas chromatography-mass spectrometry (GC-MS). In addition to acids, esters, and alcohols, benzaldehyde, vanillin, geosmin, and γ-nonalactone were identified to be potentially important to Chinse rice wine. The concentration of these aroma-active compounds in the Chinese rice wine was further quantitated by combination of four different methods, including headsapce-gas chromatography, solid phase microextraction-gas chromatography (SPME)-GC-MS, solid-phase extraction-GC-MS, and SPME-GC-pulsed flame photometric detection (PFPD). Quantitative results showed that 34 aroma compounds were at concentrations higher than their corresponding odor thresholds. On the basis of the odor activity values (OAVs), vanillin, dimethyl trisulfide, β-phenylethyl alcohol, guaiacol, geosmin, and benzaldehyde could be responsible for the unique aroma of Chinese rice wine. An aroma reconstitution model prepared by mixing 34 aroma compounds with OAVs > 1 in an odorless Chinese rice wine matrix showed a good similarity to the aroma of the original Chinese rice wine.

  8. Electro-assisted solid-phase microextraction based on poly(3,4-ethylenedioxythiophen) combined with GC for the quantification of tricyclic antidepressants.

    PubMed

    Davarani, Saied Saeed Hosseiny; Nojavan, Saeed; Asadi, Roghayeh; Banitaba, Mohammad Hossein

    2013-07-01

    In this study, a platinum wire coated with poly(3,4-ethylenedioxythiophen) was used as an electro-assisted solid-phase microextraction fiber for the quantification of tricyclic antidepressant drugs in biological samples by coupling to GC employing a flame ionization detector. In this study, an electric field increased the extraction rate and recovery. The fiber used as a solid phase was synthesized by the electropolymerization of 3,4-ethylenedioxythiophen monomers onto a platinum wire. The ability of this fiber to extract imipramine, desipramine, and clomipramine by using the electro-assisted solid-phase microextraction technique was evaluated. The effect of various parameters that influence the extraction efficiency, which include solution temperature, extraction time, stirring rate, ionic strength, time and temperature of desorption, and thickness of the fiber, was optimized. Under optimized conditions, the linear ranges and regression coefficients of calibration curves were in the range of 0.5-250 and 0.990-0.998 ng/mL, respectively. Detection limits were in the range of 0.15-0.45 ng/mL. Finally, this method was applied to the determination of drugs in urine and wastewater samples and recoveries were 4.8-108.9%. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Accurate determination of 3-alkyl-2-methoxypyrazines in wines by gas chromatography quadrupole time-of-flight tandem mass spectrometry following solid-phase extraction and dispersive liquid-liquid microextraction.

    PubMed

    Fontana, Ariel; Rodríguez, Isaac; Cela, Rafael

    2017-09-15

    A new reliable method for the determination 3-alkyl-2-methoxypyrazines (MPs) in wine samples based on the sequential combination of solid-phase extraction (SPE), dispersive liquid-liquid microextraction (DLLME) and gas chromatography (GC) quadrupole time-of-flight accurate tandem mass spectrometry (QTOF-MS/MS) is presented. Primary extraction of target analytes was carried out by using a reversed-phase Oasis HLB (200mg) SPE cartridge combined with acetonitrile as elution solvent. Afterwards, the SPE extract was submitted to DLLME concentration using 0.06mL carbon tetrachloride (CCl 4 ) as extractant. Under final working conditions, sample concentration factors above 379 times and limits of quantification (LOQs) between 0.3 and 2.1ngL -1 were achieved. Moreover, the overall extraction efficiency of the method was unaffected by the particular characteristics of each wine; thus, accurate results (relative recoveries from 84 to 108% for samples spiked at concentrations from 5 to 25ngL -1 ) were obtained using matrix-matched standards, without using standard additions over every sample. Highly selective chromatographic records were achieved considering a mass window of 5mDa, centered in the quantification product ion corresponding to each compound. Twelve commercial wines, elaborated with grapes from different varieties and geographical origins, were processed with the optimized method. The 2-isobutyl-3-methoxypyrazine (IBMP) was determined at levels above the LOQs of the method in half of the samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. A chemometric strategy for optimization of solid-phase microextraction: determination of bisphenol A and 4-nonylphenol with HPLC.

    PubMed

    Liu, Xiaoyan; Zhang, Xiaoyun; Zhang, Haixia; Liu, Mancang

    2008-08-01

    A sensitive method for the analysis of bisphenol A and 4-nonylphenol is developed by means of the optimization of solid-phase microextraction using Uniform Experimental Design methodology followed by high-performance liquid chromatographic analysis with fluorescence detection. The optimal extraction conditions are determined based on the relationship between parameters and the peak area. The curve calibration plots are linear (r2>or=0.9980) over the concentration range of 1.25-125 ng/mL for bisphenol A and 2.59-202.96 ng/mL for 4-nonylphenol, respectively. The detection limits, based on a signal-to-noise ratio of 3, are 0.097 ng/mL for bisphenol A and 0.27 ng/mL for 4-nonylphenol, respectively. The validity of the proposed method is demonstrated by the analysis of the investigated analytes in real water samples and sensitivity of the optimized method is verified by comparing results with those obtained by previous methods using the same commercial solid-phase microextraction fiber.

  11. Multivariate analysis of volatile compounds detected by headspace solid-phase microextraction/gas chromatography: A tool for sensory classification of cork stoppers.

    PubMed

    Prat, Chantal; Besalú, Emili; Bañeras, Lluís; Anticó, Enriqueta

    2011-06-15

    The volatile fraction of aqueous cork macerates of tainted and non-tainted agglomerate cork stoppers was analysed by headspace solid-phase microextraction (HS-SPME)/gas chromatography. Twenty compounds containing terpenoids, aliphatic alcohols, lignin-related compounds and others were selected and analysed in individual corks. Cork stoppers were previously classified in six different classes according to sensory descriptions including, 2,4,6-trichloroanisole taint and other frequent, non-characteristic odours found in cork. A multivariate analysis of the chromatographic data of 20 selected chemical compounds using linear discriminant analysis models helped in the differentiation of the a priori made groups. The discriminant model selected five compounds as the best combination. Selected compounds appear in the model in the following order; 2,4,6 TCA, fenchyl alcohol, 1-octen-3-ol, benzyl alcohol and benzothiazole. Unfortunately, not all six a priori differentiated sensory classes were clearly discriminated in the model, probably indicating that no measurable differences exist in the chromatographic data for some categories. The predictive analyses of a refined model in which two sensory classes were fused together resulted in a good classification. Prediction rates of control (non-tainted), TCA, musty-earthy-vegetative, vegetative and chemical descriptions were 100%, 100%, 85%, 67.3% and 100%, respectively, when the modified model was used. The multivariate analysis of chromatographic data will help in the classification of stoppers and provide a perfect complement to sensory analyses. Copyright © 2010 Elsevier Ltd. All rights reserved.

  12. Analysis of Odorants in Marking Fluid of Siberian Tiger (Panthera tigris altaica) Using Simultaneous Sensory and Chemical Analysis with Headspace Solid-Phase Microextraction and Multidimensional Gas Chromatography-Mass Spectrometry-Olfactometry.

    PubMed

    Soso, Simone B; Koziel, Jacek A

    2016-06-25

    Scent-marking is the most effective method of communication in the presence or absence of a signaler. These complex mixtures result in a multifaceted interaction triggered by the sense of smell. The objective was to identify volatile organic compound (VOC) composition and odors emitted by total marking fluid (MF) associated with Siberian tigers (Panthera tigris altaica). Siberian tiger, an endangered species, was chosen because its MF had never been analyzed. Solid phase microextraction (SPME) for headspace volatile collection combined with multidimensional gas chromatography-mass spectrometry-olfactometry for simultaneous chemical and sensory analyses were used. Thirty-two VOCs emitted from MF were identified. 2-acetyl-1-pyrroline, the sole previously identified compound responsible for the "characteristic" odor of P. tigris MF, was identified along with two additional compounds confirmed with standards (urea, furfural) and four tentatively identified compounds (3-methylbutanamine, (R)-3-methylcyclopentanone, propanedioic acid, and 3-hydroxybutanal) as being responsible for the characteristic aroma of Siberian tiger MF. Simultaneous chemical and sensory analyses improved characterization of scent-markings and identified compounds not previously reported in MF of other tiger species. This research will assist animal ecologists, behaviorists, and zookeepers in understanding how scents from specific MF compounds impact tiger and wildlife communication and improve management practices related to animal behavior. Simultaneous chemical and sensory analyses is applicable to unlocking scent-marking information for other species.

  13. Analysis of volatile human urinary metabolome by solid-phase microextraction in combination with gas chromatography-mass spectrometry for biomarker discovery: application in a pilot study to discriminate patients with renal cell carcinoma.

    PubMed

    Monteiro, Márcia; Carvalho, Márcia; Henrique, Rui; Jerónimo, Carmen; Moreira, Nathalie; de Lourdes Bastos, Maria; de Pinho, Paula Guedes

    2014-07-01

    A new and simple analytical approach consisting of headspace-solid phase microextraction (HS-SPME) sampling coupled with gas chromatography-ion trap/mass spectrometry (GC-IT/MS) was developed to study the volatile human urinary metabolome. A central composite design (CCD) was used in the optimisation of extraction conditions. Fibre selection and evaluation of pH influence were performed using an univariate mode and the influence of other parameters, such as the time and temperature of extraction, time of incubation and salt addition, that affect the efficiency of the SPME sampling, was carried out using a CCD. With a sample volume of 2 mL, the optimal conditions in terms of total response values and reproducibility were achieved by performing analyses with a divinylbenzene/polydimethylsiloxane (DVB/PDMS) fibre, in an acidic pH (pH 2) with the addition of 0.59 g of NaCl, allowing the sample to equilibrate for 9 min and extracting at 68 °C for 24 min. The applicability of the optimised method was then tested in a pilot non-target analysis of urine samples obtained from patients with renal cell carcinoma (RCC) and healthy individuals. Chemometric unsupervised analyses performed on the volatile pattern acquired for these samples clearly showed the potential of volatile urinary metabolome to discriminate between RCC and control patients. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Carbon nanotubes@silicon dioxide nanohybrids coating for solid-phase microextraction of organophosphorus pesticides followed by gas chromatography-corona discharge ion mobility spectrometric detection.

    PubMed

    Saraji, Mohammad; Jafari, Mohammad Taghi; Mossaddegh, Mehdi

    2016-01-15

    A high efficiency solid-phase microextraction (SPME) fiber coated with porous carbon nanotubes-silicon dioxide (CNTs-SiO2) nanohybrids was synthesized and applied for the determination of some organophosphorus pesticides (OPPs) in vegetables, fruits and water samples. Gas chromatography-corona discharge ion mobility spectrometry was used as the detection system. Glucose, as a biocompatible compound, was used for connecting CNT and SiO2 during a hydrothermal process. The electrospinning technique was also applied for the fiber preparation. The parameters affecting the efficiency of extraction, including stirring rate, salt effect, extraction temperature, extraction time, desorption temperature and desorption time, were investigated and optimized. The developed CNTs@SiO2 fiber presented better extraction efficiency than the commercial SPME fibers (PA, PDMS, and PDMS-DVB). The intra- and inter-day relative standard deviations were found to be lower than 6.2 and 9.0%, respectively. For water samples, the limits of detection were in the range of 0.005-0.020 μg L(-1) and the limits of quantification were between 0.010 and 0.050 μg L(-1). The results showed a good linearity in the range of 0.01-3.0 μg L(-1) for the analytes. The spiking recoveries ranged from 79 (± 9) to 99 (± 8). The method was successfully applied for the determination of OPPs in real samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Solid-phase microextraction gas chromatography-mass spectrometry determination of fragrance allergens in baby bathwater.

    PubMed

    Lamas, J Pablo; Sanchez-Prado, Lucia; Garcia-Jares, Carmen; Llompart, Maria

    2009-07-01

    A method based on solid-phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS) has been optimized for the determination of fragrance allergens in water samples. This is the first study devoted to this family of cosmetic ingredients performed by SPME. The influence of parameters such as fibre coating, extraction and desorption temperatures, salting-out effect and sampling mode on the extraction efficiency has been studied by means of a mixed-level factorial design, which allowed the study of the main effects as well as two-factor interactions. Excluding desorption temperature, the other parameters were, in general, very important for the achievement of high response. The final procedure was based on headspace sampling at 100 degrees C, using polydimethylsiloxane/divinylbenzene fibres. The method showed good linearity and precision for all compounds, with detection limits ranging from 0.001 to 0.3 ng mL(-1). Reliability was demonstrated through the evaluation of the recoveries in different real water samples, including baby bathwater and swimming pool water. The absence of matrix effects allowed the use of external standard calibration to quantify the target compounds in the samples. The proposed procedure was applied to the determination of allergens in several real samples. All the target compounds were found in the samples, and, in some cases, at quite high concentrations. The presence and the levels of these chemicals in baby bathwater should be a matter of concern.

  16. [Determination of flavor compounds in foxtail millet wine by gas chromatography-mass spectrometry coupled with headspace solid phase microextraction].

    PubMed

    Liu, Jingke; Zhang, Aixia; Li, Shaohui; Zhao, Wei; Zhang, Yuzong; Xing, Guosheng

    2017-11-08

    To comprehensively understand flavor compounds and aroma characteristics of foxtail millet wine, extraction conditions were optimized with 85 μm polyacrylate (PA), 100 μm polydimethylsiloxane (PDMS), 75 μm carboxen (CAR)/PDMS and 50/30 μm divinylbenzene (DVB)/CAR/PDMS fibers. The flavor compounds in foxtail millet wine were investigated by gas chromatography-mass spectrometry (GC-MS) coupled with headspace solid phase microextraction (HS-SPME), and the odor characteristics and intensity were analyzed by odor active values (OAVs). The samples of 8 mL were placed in headspace vials with 1.5 g NaCl, then the headspace vials were heated at 60℃ for 40 min. Using HS-SPME with different fibers, a total of 55 flavor compounds were identified from the samples, including alcohols, esters, benzene derivatives, hydrocarbons, acids, aldehydes, ketones, terpenes, phenols and heterocycle compounds. The main flavor compounds were alcohols compounds. According to their OAVs, phenylethyl alcohol, styrene, 1-methyl-naphthalene, 2-methyl-naphthalene, benzaldehyde, benzeneacetaldehyde and 2-methoxy-phenol were established to be odor-active compounds. Phenylethyl alcohol and benzeneacetaldehyde were the most prominent odor-active compounds. PA and PDMS fibers had good extraction effect for polar and nonpolar compounds, respectively. CAR/PDMS and DVB/CAR/PDMS provided a similar compounds profile for moderate polar compounds. This research comprehensively determined flavor compounds of foxtail millet wine, and provided theoretical basis for product development and quality control.

  17. Characterization of Volatile Sulfur Compounds in Moutai Liquors by Headspace Solid-Phase Microextraction Gas Chromatography-Pulsed Flame Photometric Detection and Odor Activity Value.

    PubMed

    Chen, Shuang; Sha, Sha; Qian, Michael; Xu, Yan

    2017-12-01

    This study investigated the aroma contribution of volatile sulfur compounds (VSCs) in Moutai liquors. The VSCs were analyzed using headspace solid-phase microextraction-gas chromatography-pulsed flame photometric detection (HS-SPME-GC-PFPD). The influences of SPME fibers, ethanol content in the sample, pre-incubation time, and extraction temperature and time on the extraction of VSCs were optimized. The VSCs were optimally extracted using a divinylbenzene/carboxen/polydimethylsiloxane fiber, by incubating 10 mL diluted Chinese liquor (5% vol.) with 3 g NaCl at 30 °C for 15 min, followed by a subsequent extraction for 40 min at 30 °C. The optimized method was further validated. A total of 13 VSCs were identified and quantified in Moutai liquors. The aroma contribution of these VSCs were evaluated by their odor activity values (OAVs), with the result that 7 of 13 VSCs had OAVs > 1. In particular, 2-furfurylthiol, methanethiol, dimethyl trisulfide, ethanethiol, and methional had relatively high OAVs and could be the key aroma contributors to Moutai liquors. In this study, a method for analyzing volatile sulfur compounds in Chinese liquors has been developed. This method will allow an in-depth study the aroma contribution of volatile sulfur compounds in Chinese liquors. Seven volatile sulfur compounds were identified as potential key aroma contributors for Moutai liquors, which can help to the quality control of Moutai liquors. © 2017 Institute of Food Technologists®.

  18. Development of a simultaneous multiple solid-phase microextraction-single shot-gas chromatography/mass spectrometry method and application to aroma profile analysis of commercial coffee.

    PubMed

    Lee, Changgook; Lee, Younghoon; Lee, Jae-Gon; Buglass, Alan J

    2013-06-21

    A simultaneous multiple solid-phase microextraction-single shot-gas chromatography mass spectrometry (smSPME-ss-GC/MS) method has been developed for headspace analysis. Up to four fibers (50/30 μm DVB/CAR/PDMS) were used simultaneously for the extraction of aroma components from the headspace of a single sample chamber in order to increase sensitivity of aroma extraction. To avoid peak broadening and to maximize resolution, a simple cryofocusing technique was adopted during sequential thermal desorption of multiple SPME fibers prior to a 'single shot' chromatographic run. The method was developed and validated on a model flavor mixture, containing 81 known pure components. With the conditions of 10 min of incubation and 30 min of extraction at 50 °C, single, dual, triple and quadruple SPME extractions were compared. The increase in total peak area with increase in the number of fibers showed good linearity (R(2)=0.9917) and the mean precision was 12.0% (RSD) for the total peak sum, with quadruple simultaneous SPME extraction. Using a real sample such as commercial coffee granules, aroma profile analysis was conducted using single, dual, triple and quadruple SPME fibers. The increase in total peak intensity again showed good linearity with increase in the number of SPME fibers used (R(2)=0.9992) and the precision of quadruple SPME extraction was 9.9% (RSD) for the total peak sum. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Simultaneous quantification of Aroclor mixtures in soil samples by gas chromatography/mass spectrometry with solid phase microextraction using partial least-squares regression.

    PubMed

    Zhang, Mengliang; Harrington, Peter de B

    2015-01-01

    Multivariate partial least-squares (PLS) method was applied to the quantification of two complex polychlorinated biphenyls (PCBs) commercial mixtures, Aroclor 1254 and 1260, in a soil matrix. PCBs in soil samples were extracted by headspace solid phase microextraction (SPME) and determined by gas chromatography/mass spectrometry (GC/MS). Decachlorinated biphenyl (deca-CB) was used as internal standard. After the baseline correction was applied, four data representations including extracted ion chromatograms (EIC) for Aroclor 1254, EIC for Aroclor 1260, EIC for both Aroclors and two-way data sets were constructed for PLS-1 and PLS-2 calibrations and evaluated with respect to quantitative prediction accuracy. The PLS model was optimized with respect to the number of latent variables using cross validation of the calibration data set. The validation of the method was performed with certified soil samples and real field soil samples and the predicted concentrations for both Aroclors using EIC data sets agreed with the certified values. The linear range of the method was from 10μgkg(-1) to 1000μgkg(-1) for both Aroclor 1254 and 1260 in soil matrices and the detection limit was 4μgkg(-1) for Aroclor 1254 and 6μgkg(-1) for Aroclor 1260. This holistic approach for the determination of mixtures of complex samples has broad application to environmental forensics and modeling. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Headspace solid phase microextraction and gas chromatography-olfactometry dilution analysis of young and aged Chinese "Yanghe Daqu" liquors.

    PubMed

    Fan, Wenlai; Qian, Michael C

    2005-10-05

    The aroma compounds of young and aged Chinese "Yanghe Daqu" liquor samples were extracted by solid phase microextraction (SPME) and analyzed by gas chromatography (GC)-olfactometry dilution analysis. The original liquor samples were diluted with deionized water to give a final alcohol content of 14% (v/v). The samples were stepwise diluted (1:1) with 14% (by volume) ethanol-water solution and then extracted by headspace SPME. The samples were preequilibrated at 50 degrees C for 15 min and extracted with stirring at the same temperature for 30 min prior to injection into GC. The aroma compounds were identified by both GC-MS and GC-olfactometry using DB-Wax and DB-5 columns. The results suggested that esters were the major contributors to Yanghe Daqu liquor aroma. Ethyl hexanoate, ethyl butanoate, and ethyl pentanoate had very high flavor dilution values in both young and aged liquors (FD > 8192). Methyl hexanoate, ethyl heptanoate, ethyl benzoate, and butyl hexanoate could also be very important because of their high flavor dilution values (FD > or = 256). Moreover, two acetals, 1,1-diethoxyethane and 1,1-diethoxy-3-methylbutane, also were shown high flavor dilution values in Yanghe Daqu liquors (FD > or = 256). Other aroma compounds having moderate flavor dilution values included acetaldehyde, 3-methylbutanol, and 2-pentanol (FD > or = 32). Comparing young and aged liquors, the aroma profiles were similar, but the aroma compounds in the aged sample had higher flavor dilution values than in the young ones.

  1. Optimization of headspace solid phase microextraction based on nano-structured ZnO combined with gas chromatography-mass spectrometry for preconcentration and determination of ultra-traces of chlorobenzenes in environmental samples.

    PubMed

    Ghasemi, Ensieh; Sillanpää, Mika

    2014-12-01

    In this study, a simple, novel and efficient preconcentration method for the determination of some chlorobenzenes (monochlorobenzene (MCB), three isomeric forms of dichlorobenzene (diCB), 1,3,5-trichlorobenzene (triCB) and hexachlorobenze (hexaCB)) has been developed using a headspace solid phase microextraction (HS-SPME) based on nano-structured ZnO combined with capillary gas chromatography-mass spectrometry (GC-MS). ZnO nanorods have been grown on fused silica fibers using a hydrothermal process. The diameter of ZnO nanorods was in the range of 50-80 nm. The effect of different variables on the extraction efficiency was studied simultaneously using an experimental design. The variables of interest in the HS-SPME were stirring rate, desorption time and temperature, ionic strength, extraction time and temperature. For this purpose, a multivariate strategy was applied based on an experimental design using a Plackett-Burman design for screening and a Box-Behnken design for optimizing of the significant factors. The detection limit and relative standard deviation (RSD) (n=5) for the target analytes were in the range of 0.01-0.1 ng L(-1) and 4.3-7.6%, respectively. The developed technique was found to be successfully applicable to preconcentration and determination of the target analytes in environmental water and soil samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Simultaneous determination of estrogenic odorant alkylphenols, chlorophenols, and their derivatives in water using online headspace solid phase microextraction coupled with gas chromatography-mass spectrometry.

    PubMed

    Yuan, Su-Fen; Liu, Ze-Hua; Lian, Hai-Xian; Yang, Chuangtao; Lin, Qing; Yin, Hua; Dang, Zhi

    2016-10-01

    A simple online headspace solid-phase microextraction (HS-SPME) coupled with the gas chromatography-mass spectrometry (GC-MS) method was developed for simultaneous determination of trace amounts of nine estrogenic odorant alkylphenols and chlorophenols and their derivatives in water samples. The extraction conditions of HS-SPME were optimized including fiber selection, extraction temperature, extraction time, and salt concentration. Results showed that divinylbenzene/Carboxen/polydimethylsiloxane (DVB/CAR/PDMS) fiber was the most appropriate one among the three selected commercial fibers, and the optimal extraction temperature, time, and salt concentration were 70 °C, 30 min, and 0.25 g/mL, respectively. The developed method was validated and showed good linearity (R (2) > 0.989), low limit of detection (LOD, 0.002-0.5 μg/L), and excellent recoveries (76-126 %) with low relative standard deviation (RSD, 0.7-12.9 %). The developed method was finally applied to two surface water samples and some of these target compounds were detected. All these detected compounds were below their odor thresholds, except for 2,4,6-TCAS and 2,4,6-TBAS wherein their concentrations were near their odor thresholds. However, in the two surface water samples, these detected compounds contributed to a certain amount of estrogenicity, which seemed to suggest that more attention should be paid to the issue of estrogenicity rather than to the odor problem.

  3. Development and optimization of a solid-phase microextraction gas chromatography-tandem mass spectrometry methodology to analyse ultraviolet filters in beach sand.

    PubMed

    Vila, Marlene; Llompart, Maria; Garcia-Jares, Carmen; Homem, Vera; Dagnac, Thierry

    2018-06-06

    A methodology based on solid-phase microextraction (SPME) followed by gas chromatography-tandem mass spectrometry (GC-MS/MS) has been developed for the simultaneous analysis of eleven multiclass ultraviolet (UV) filters in beach sand. To the best of our knowledge, this is the first time that this extraction technique is applied to the analysis of UV filters in sand samples, and in other kind of environmental solid samples. Main extraction parameters such as the fibre coating, the amount of sample, the addition of salt, the volume of water added to the sand, and the temperature were optimized. An experimental design approach was implemented in order to find out the most favourable conditions. The final conditions consisted of adding 1 mL of water to 1 g of sample followed by the headspace SPME for 20 min at 100 °C, using PDMS/DVB as fibre coating. The SPME-GC-MS/MS method was validated in terms of linearity, accuracy, limits of detection and quantification, and precision. Recovery studies were also performed at three concentration levels in real Atlantic and Mediterranean sand samples. The recoveries were generally above 85% and relative standard deviations below 11%. The limits of detection were in the pg g -1 level. The validated methodology was successfully applied to the analysis of real sand samples collected from Atlantic Ocean beaches in the Northwest coast of Spain and Portugal, Canary Islands (Spain), and from Mediterranean Sea beaches in Mallorca Island (Spain). The most frequently found UV filters were ethylhexyl salicylate (EHS), homosalate (HMS), 4-methylbenzylidene camphor (4MBC), 2-ethylhexyl methoxycinnamate (2EHMC) and octocrylene (OCR), with concentrations up to 670 ng g -1 . Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Aroma compound analysis of Piper nigrum and Piper guineense essential oils from Cameroon using solid-phase microextraction-gas chromatography, solid-phase microextraction-gas chromatography-mass spectrometry and olfactometry.

    PubMed

    Jirovetz, Leopold; Buchbauer, Gerhard; Ngassoum, Martin Benoit; Geissler, Margit

    2002-11-08

    The investigation of aroma compounds of the essential oils of dried fruits of black pepper (Piper nigrum) and black and white "Ashanti pepper" (Piper guineense) from Cameroon by means of solid-phase microextraction (SPME) was carried out for the first time to identify the odorous target components responsible for the characteristic odor of these valuable spices and food flavoring products. By means of GC-flame ionization detection (FID) and GC-MS (using different polar columns) the main compounds (concentration >3.0%, calculated as area of GC-FID analysis using a non-polar fused-silica open tubular RSL-200 column) of the SPME headspace samples of P. nigrum (black) and P. guineense (black and white) were found to be: P. nigrum (black)--germacrene D (11.01%), limonene (10.26%), beta-pinene (10.02%), alpha-phellandrene (8.56%), beta-caryophyllene (7.29%), alpha-pinene (6.40%) and cis-beta-ocimene (3.19%); P. guineense (black)--beta-caryophyllene (57.59%), beta-elemene (5.10%), bicyclogermacrene (5.05%) and alpha-humulene (4.86%); and P. guineense (white)--beta-caryophyllene (51.75%), cis-beta-ocimene (6.61%), limonene (5.88%), beta-pinene (4.56%), linalool (3.97%) and alpha-humulene (3.29%). The most intense odor impressions of the essential oils of the various dried pepper fruits were given byprofessional perfumers as follows: P nigrum (black)--fine, pleasant black pepper note; P. guineense (black)--black pepper top-note; and P. guineense (white)--pleasant white pepper note. These analytical results for the SPME headspace samples of three different pepper species from Cameroon are in accordance with the olfactoric data of the corresponding essential oils. A GC-sniffing technique was used to correlate the single odor impression of the identified SPME headspace volatiles of the three investigated pepper samples with the following results: themain compounds such as beta-caryophyllene, germacrene D, limonene, beta-pinene, alpha-phellandrene and alpha-humulene, as well as minor constituents such as delta-carene, beta-phellandrene, isoborneol, alpha-guaiene, sarisan, elemicin, calamenene, caryophyllene alcohol, isoelemicin, T-muurolol, cubenol and bulnesol, are of greatest importance for the characteristic pepper odor notes of these three Piper samples. Further aroma impressions can be attributed to mono- and sesquiterpenes, hexane, octane and nonane derivatives.

  5. Matrix solid-phase dispersion coupled with homogeneous ionic liquid microextraction for the determination of sulfonamides in animal tissues using high-performance liquid chromatography.

    PubMed

    Wang, Zhibing; He, Mengyu; Jiang, Chunzhu; Zhang, Fengqing; Du, Shanshan; Feng, Wennan; Zhang, Hanqi

    2015-12-01

    Matrix solid-phase dispersion coupled with homogeneous ionic liquid microextraction was developed and applied to the extraction of some sulfonamides, including sulfamerazine, sulfamethazine, sulfathiazole, sulfachloropyridazine, sulfadoxine, sulfisoxazole, and sulfaphenazole, in animal tissues. High-performance liquid chromatography was applied to the separation and determination of the target analytes. The solid sample was directly treated by matrix solid-phase dispersion and the eluate obtained was treated by homogeneous ionic liquid microextraction. The ionic liquid was used as the extraction solvent in this method, which may result in the improvement of the recoveries of the target analytes. To avoid using organic solvent and reduce environmental pollution, water was used as the elution solvent of matrix solid-phase dispersion. The effects of the experimental parameters on recoveries, including the type and volume of ionic liquid, type of dispersant, ratio of sample to dispersant, pH value of elution solvent, volume of elution solvent, amount of salt in eluate, amount of ion-pairing agent (NH4 PF6 ), and centrifuging time, were evaluated. When the present method was applied to the analysis of animal tissues, the recoveries of the analytes ranged from 85.4 to 118.0%, and the relative standard deviations were lower than 9.30%. The detection limits for the analytes were 4.3-13.4 μg/kg. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Simultaneous Analysis of 22 Volatile Organic Compounds in Cigarette Smoke Using Gas Sampling Bags for High-Throughput Solid-Phase Microextraction

    PubMed Central

    Sampson, Maureen M.; Chambers, David M.; Pazo, Daniel Y.; Moliere, Fallon; Blount, Benjamin C.; Watson, Clifford H.

    2015-01-01

    Quantifying volatile organic compounds (VOCs) in cigarette smoke is necessary to establish smoke-related exposure estimates and evaluate emerging products and potential reduced-exposure products. In response to this need, we developed an automated, multi-VOC quantification method for machine-generated, mainstream cigarette smoke using solidphase microextraction gas chromatography–mass spectrometry (SPME-GC–MS). This method was developed to simultaneously quantify a broad range of smoke VOCs (i.e., carbonyls and volatiles, which historically have been measured by separate assays) for large exposure assessment studies. Our approach collects and maintains vapor-phase smoke in a gas sampling bag, where it is homogenized with isotopically labeled analogue internal standards and sampled using gas-phase SPME. High throughput is achieved by SPME automation using a CTC Analytics platform and custom bag tray. This method has successfully quantified 22 structurally diverse VOCs (e.g., benzene and associated monoaromatics, aldehydes and ketones, furans, acrylonitrile, 1,3-butadiene, vinyl chloride, and nitromethane) in the microgram range in mainstream smoke from 1R5F and 3R4F research cigarettes smoked under ISO (Cambridge Filter or FTC) and Intense (Health Canada or Canadian Intense) conditions. Our results are comparable to previous studies with few exceptions. Method accuracy was evaluated with third-party reference samples (≤15% error). Short-term diffusion losses from the gas sampling bag were minimal, with a 10% decrease in absolute response after 24 h. For most analytes, research cigarette inter- and intrarun precisions were ≤20% relative standard deviation (RSD). This method provides an accurate and robust means to quantify VOCs in cigarette smoke spanning a range of yields that is sufficient to characterize smoke exposure estimates. PMID:24933649

  7. Ionic Liquid-Bonded Fused Silica as a New Solid-Phase Microextraction Fiber for the Liquid Chromatographic Determination of Bisphenol A as an Endocrine Disruptor.

    PubMed

    Mohammadnezhad, Nasim; Matin, Amir Abbas; Samadi, Naser; Shomali, Ashkan; Valizadeh, Hassan

    2017-01-01

    Linear ionic liquid bonded to fused silica and its application as a solid-phase microextraction fiber for the extraction of bisphenol A (BPA) from water samples were studied. After optimization of microextraction conditions (15 mL sample volume, extraction time of 40 min, extraction temperature of 30 ± 1°C, 300 μL acetonitrile as the desorption solvent, and desorption time of 7 min), the fiber was used to extract BPA from packed mineral water, followed by HPLC-UV on an XDB-C18 column (150 × 4.6 mm id, 3.5 μm particle) with a mobile phase of acetonitrile-water (45 + 55%, v/v) and flow rate of 1 mL . min-1). A low LOD (0.20 μg . L-1) and good linearity (0.9977) in the calibration graph indicated that the proposed method was suitable for the determination of BPA.

  8. Headspace solid-phase microextraction (HS-SPME) combined with GC-MS as a process analytical technology (PAT) tool for monitoring the cultivation of C. tetani.

    PubMed

    Ghader, Masoud; Shokoufi, Nader; Es-Haghi, Ali; Kargosha, Kazem

    2018-04-15

    Vaccine production is a biological process in which variation in time and output is inevitable. Thus, the application of Process Analytical Technologies (PAT) will be important in this regard. Headspace solid - phase microextraction (HS-SPME) coupled with GC-MS can be used as a PAT for process monitoring. This method is suitable to chemical profiling of volatile organic compounds (VOCs) emitted from microorganisms. Tetanus is a lethal disease caused by Clostridium tetani (C. tetani) bacterium and vaccination is an ultimate way to prevent this disease. In this paper, SPME fiber was used for the investigation of VOCs emerging from C. tetani during cultivation. Different types of VOCs such as sulfur-containing compounds were identified and some of them were selected as biomarkers for bioreactor monitoring during vaccine production. In the second step, the portable dynamic air sampling (PDAS) device was used as an interface for sampling VOCs by SPME fibers. The sampling procedure was optimized by face-centered central composite design (FC-CCD). The optimized sampling time and inlet gas flow rates were 10 min and 2 m L s -1 , respectively. PDAS was mounted in exhausted gas line of bioreactor and 42 samples of VOCs were prepared by SPME fibers in 7 days during incubation. Simultaneously, pH and optical density (OD) were evaluated to cultivation process which showed good correlations with the identified VOCs (>80%). This method could be used for VOCs sampling from off-gas of a bioreactor to monitoring of the cultivation process. Copyright © 2018. Published by Elsevier B.V.

  9. Monitoring the emission of volatile organic compounds from flowers of Jasminum sambac using solid-phase micro-extraction fibers and gas chromatography with mass spectrometry detection.

    PubMed

    Pragadheesh, Vppalayam Shanmugam; Yadav, Anju; Chanotiya, Chandan Singh; Rout, Prasanta Kumar; Uniyal, Girish Chandra

    2011-09-01

    Solid-phase micro-extraction (SPME) was studied as a solvent free alternative method for the extraction and characterization of volatile compounds in intact and plucked flowers of Jasminum sambac at different day time intervals using gas chromatography (GC-FID) and gas chromatography-quadrupole mass spectrometry. The analytes identified included alcohols, esters, phenolic compounds, and terpenoids. The main constituents identified in the flower aroma using different fibers were cis-3-hexenyl acetate, (E)-beta-ocimene, linalool, benzyl acetate, and (E,E)-alpha-farnesene. The benzyl acetate proportion decreased from morning to afternoon and then increased in evening collections. PDMS fiber showed a high proportion of (E,E)-alpha-farnesene in jasmine floral aroma. Among other constituents identified, cis-3-hexenyl acetate, linalool, and benzyl acetate were major aroma contributors in plucked and living flowers extracts using PDMS/DVB, Carboxen/PDMS, and DVB/Carboxen/PDMS fibers. PDMS/DVB recorded the highest emission for benzyl acetate while the (E)-beta-ocimene proportion was highest in DVB/Carboxen/PDMS when compared with the rest. The highest linalool content, with increasing proportion from morning to noon, was found using mixed coating fibers. Almost negligible volatile adsorption was recorded for the polyacrylate fiber for intact flower aroma, whereas it was most effective for benzyl acetate, followed by indole under plucked conditions. Moreover, the highest amounts extracted, evaluated from the sum of peak areas, were achieved using Carboxen/PDMS, and DVB/Carboxen/PDMS. Introduction of a rapid, and solvent free SPME method for the analysis of multicomponent volatiles can be successfully employed to monitor the extraction and characterization of flower aroma constituents.

  10. Head space solid phase microextraction based on nano-structured lead dioxide: application to the speciation of volatile organoselenium in environmental and biological samples.

    PubMed

    Ghasemi, Ensieh; Farahani, Hadi

    2012-10-05

    A novel and efficient speciation method based on the nano-structured lead dioxide as stationary phase of head space solid phase microextraction combined with gas chromatography mass spectrometry (GC-MS) was developed for the determination of volatile organoselenium compounds (dimethylselenide (DMSe) and dimethyldiselenide (DMDSe)) in different biological and environmental samples. PbO(2) particles with a diameter in the range of 50-70 nm have been grown on platinum wire via elechtrochemical deposition. The effect of different variables on the extraction efficiency was studied simultaneously using an experimental design. The variables of interest in the HS-SPME were condition of coating preparation, desorption time, stirring rate, desorption temperature, ionic strength, time and temperature of extraction. A Plackett-Burman design was performed for screening in order to determine the significant variables affecting the extraction efficiency. Then, the significant factors were optimized by a Box-Behnken design (BBD) and the response surface equations were derived. The detection limit and relative standard deviation (RSD) (n=5, c=50 μgL(-1)) for DMSe were 16 ngL(-1) and 4.3%, respectively. They were also obtained for DMDSe as 11ngL(-1) and 4.6%, respectively. The developed technique was found to be applicable to spiked environmental and biological samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Characterization of Human Skin Emanations by Solid Phase Microextraction (SPME) Extraction of Volatiles and Subsequent Analysis by Gas Chromatography-Mass Spectrometry (GC-MS)

    DTIC Science & Technology

    2005-05-06

    Figure 12: Overlaid TICs of Multiple Extractions for Donor 18 Figure 13: Two Sets of Twins on Same Day Figure 14: Sectioning of Socks for Sock Odors ...considerations they provoked, i.e. sock odors , induced perspiration, Twister® extraction, and glass beads rubbed on hands (which was ultimately...Substances 2.1.2.1 Socks Worn on Feet for Three to Four Hours To test the viability of collecting odors from fragments of clothing, an experiment was

  12. Volatile compound in cut and un-cut flowers of tetraploid Freesia hybrida.

    PubMed

    Ao, Man; Liu, Baofeng; Wang, Li

    2013-01-01

    The flower volatile compounds (FVCs) of two tetraploid Freesia hybrida (pink-yellow and yellow) cultivars and their cut flowers were analysed by headspace solid-phase microextraction combined with gas chromatography-mass spectrometry. Twelve FVCs were identified in the pink-yellow cultivar, with linalool as the major compound; 30 FVCs were identified in the yellow cultivar, with linalool and terpineol as the two major compounds. The FVCs (>1%) of the two cut flower cultivars were very similar to that of the un-cut flowers, and no significant difference was observed.

  13. Quantitative Measurement of Bromoform in Swimming Pool Water Using SPME with GC-MS. An Undergraduate Instrumental Analysis Experiment

    NASA Astrophysics Data System (ADS)

    Hardee, John R.; Long, John; Otts, Julie

    2002-05-01

    A senior-level undergraduate laboratory experiment that demonstrates the use of solid-phase microextraction (SPME) and capillary gas chromatography-mass spectrometry (GC-MS) was developed for the quantitative determination of bromoform in swimming pool water. Bromoform was extracted by SPME from the headspace of vials containing sodium chloride-saturated swimming pool water. Bromoform concentrations were determined from comparisons of peak areas on a student-generated calibration curve. Students compared results to OSHA water and air exposure limits for bromoform.

  14. Ultrasound-assisted magnetic dispersive solid-phase microextraction: A novel approach for the rapid and efficient microextraction of naproxen and ibuprofen employing experimental design with high-performance liquid chromatography.

    PubMed

    Ghorbani, Mahdi; Chamsaz, Mahmoud; Rounaghi, Gholam Hossein

    2016-03-01

    A simple, rapid, and sensitive method for the determination of naproxen and ibuprofen in complex biological and water matrices (cow milk, human urine, river, and well water samples) has been developed using ultrasound-assisted magnetic dispersive solid-phase microextraction. Magnetic ethylendiamine-functionalized graphene oxide nanocomposite was synthesized and used as a novel adsorbent for the microextraction process and showed great adsorptive ability toward these analytes. Different parameters affecting the microextraction were optimized with the aid of the experimental design approach. A Plackett-Burman screening design was used to study the main variables affecting the microextraction process, and the Box-Behnken optimization design was used to optimize the previously selected variables for extraction of naproxen and ibuprofen. The optimized technique provides good repeatability (relative standard deviations of the intraday precision 3.1 and 3.3, interday precision of 5.6 and 6.1%), linearity (0.1-500 and 0.3-650 ng/mL), low limits of detection (0.03 and 0.1 ng/mL), and a high enrichment factor (168 and 146) for naproxen and ibuprofen, respectively. The proposed method can be successfully applied in routine analysis for determination of naproxen and ibuprofen in cow milk, human urine, and real water samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Determination of transformation products of unsymmetrical dimethylhydrazine in water using vacuum-assisted headspace solid-phase microextraction.

    PubMed

    Orazbayeva, Dina; Kenessov, Bulat; Psillakis, Elefteria; Nassyrova, Dayana; Bektassov, Marat

    2018-06-22

    A new, sensitive and simple method based on vacuum-assisted headspace solid-phase microextraction (Vac-HSSPME) followed by gas chromatography-mass-spectrometry (GC-MS), is proposed for the quantification of rocket fuel unsymmetrical dimethylhydrazine (UDMH) transformation products in water samples. The target transformation products were: pyrazine, 1-methyl-1H-pyrazole, N-nitrosodimethylamine, N,N-dimethylformamide, 1-methyl-1Н-1,2,4-triazole, 1-methyl-imidazole and 1H-pyrazole. For these analytes and within shorter sampling times, Vac-HSSPME yielded detection limits (0.5-100 ng L -1 ) 3-10 times lower than those reported for regular HSSPME. Vac-HSSPME sampling for 30 min at 50 °C yielded the best combination of analyte responses and their standard deviations (<15%). 1-Formyl-2,2-dimethylhydrazine and formamide were discarded because of the poor precision and accuracy when using Vac-HSSPME. The recoveries for the rest of the analytes ranged between 80 and 119%. The modified Mininert valve and Thermogreen septum could be used for automated extraction as it ensured stable analyte signals even after long waiting times (>24 h). Finally, multiple Vac-HSSME proved to be an efficient tool for controlling the matrix effect and quantifying UDMH transformation products. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Diffusive sampling of methylene chloride with solid phase microextraction.

    PubMed

    Chen, Cheng-Yao; Hsiech, Chunming; Lin, Jia-Ming

    2006-12-29

    This study examined the characteristics of a solid phase microextraction (SPME) assembly as a passive sampler to determine the short-term exposure level (STEL) of methylene chloride. Two types of SPME fibers and six sampling-related factors were chosen and nested in an L(18) Taguchi's orthogonal array. Samples were thermally desorpted and analyzed by gas chromatograph equipped with an electron capture detector (GC/ECD). The use of 85-mum Carboxen/polydimethylsiloxane (Car/PDMS) fibers resulted in greater adsorbed mass, which was highly correlated with the product of concentration and sampling time (r>0.99, p<0.0001), than 85-microm polyacrylate fibers. The sampling rate (SR) of the 85-microm Carboxen/polydimethylsiloxane fibers was not significantly affected by variations in relative humidity (0-80%) and coexistent toluene (none to 100 ppm). Variance of sampling rate was predominantly attributed to the diffusive path length (86.4%) and sampling time (5.7%). With diffusive paths of 3, 10 and 15 mm, the sampling rates of 85-microm Carboxen/polydimethylsiloxane fibers for methylene chloride were 1.4 x 10(-2), 7.7 x 10(-3) and 5.1 x1 0(-3)mL min(-1), respectively. The measured sampling rates were greater than the theoretical values, and decreased with increment of sampling time until they came to constant.

  17. Development and application of a new solid-phase microextraction fiber by sol-gel technology on titanium wire.

    PubMed

    Es-haghi, Ali; Hosseini, Seyed Maryam; Khoshhesab, Zahra Monsef

    2012-09-12

    Novel solid-phase microextraction fibers were prepared based on sol-gel technique. Commonly used fused silica substrate was replaced by titanium wire which provided high strength and longer fiber life cycle. Titanium isopropoxide was employed as the precursor which provides a sol solution containing Ti-OH groups and shows more tendencies to the molecularly similar group on the substrate. Three different polymers, poly (dimethylsiloxane) (PDMS), poly(ethylenepropyleneglycol)-monobutyl ether (Ucon) and polyethylene glycol (PEG) were employed as coating polymer in preparing three different fibers. The applicability of these fibers was assessed for the headspace SPME (HS-SPME) of benzene, toluene, ethylbenzene and xylenes (BTEX) from water sample followed by gas chromatography-mass spectrometry (GC-MS). Effects of different parameters such as fiber coating type, extraction condition, desorption condition were investigated and optimized. Under the optimized conditions, LODs and LOQs of 0.75-10 μg L(-1) (S/N=3) and 1-20 μg L(-1) (S/N=10) were respectively obtained. The method showed linearity in the range of 10-25,000 μg L(-1) with correlation coefficient of >0.99. The relative standard deviation was less than 8%. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Polydimethylsiloxane/metal-organic frameworks coated fiber for solid-phase microextraction of polycyclic aromatic hydrocarbons in river and lake water samples.

    PubMed

    Zhang, Guijiang; Zang, Xiaohuan; Li, Zhi; Wang, Chun; Wang, Zhi

    2014-11-01

    In this study, polydimethylsiloxane/metal-organic frameworks (PDMS/MOFs), including PDMS/MIL-101 and PDMS/MOF-199, were immobilized onto a stainless steel wire through sol-gel technique as solid-phase microextraction (SPME) fiber coating. The prepared fibers were used for the extraction of some polycyclic aromatic hydrocarbons (PAHs) from water samples prior to gas chromatography-mass spectrometry (GC-MS) analysis. Under the optimized experiment conditions, the PDMS/MIL-101 coated fiber exhibited higher extraction efficiency towards PAHs than that of PDMS/MOF-199. Several parameters affecting the extraction of PAHs by SPME with PDMS/MIL-101 fiber, including the extraction temperature, extraction time, sample volume, salt addition and desorption conditions, were investigated. The limits of detection (LODs) were less than 4.0 ng L(-1) and the linearity was observed in the range from 0.01 to 2.0 µg L(-1) with the correlation coefficients (r) ranging from 0.9940 to 0.9986. The recoveries of the method for the PAHs from water samples at spiking levels of 0.05 and 0.2 µg L(-1) ranged from 78.2% to 110.3%. Single fiber repeatability and fiber-to-fiber reproducibility were less than 9.3% and 13.8%, respectively. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Headspace Solid-Phase Microextraction and Ultrasonic Extraction with the Solvent Sequences in Chemical Profiling of Allium ursinum L. Honey.

    PubMed

    Jerković, Igor; Kuś, Piotr M

    2017-11-06

    A volatile profile of ramson (wild garlic, Allium ursinum L.) honey was investigated by headspace solid-phase microextraction (HS-SPME) and ultrasonic solvent extraction (USE) followed by gas chromatography and mass spectrometry (GC-FID/GC-MS) analyses. The headspace was dominated by linalool derivatives: cis - and trans -linalool oxides (25.3%; 9.2%), hotrienol (12.7%), and linalool (5.8%). Besides direct extraction with dichloromethane and pentane/diethyl ether mixture (1:2, v / v ), two solvent sequences (I: pentane → diethyl ether; II: pentane → pentane/diethyl ether (1:2, v / v ) → dichloromethane) were applied. Striking differences were noted among the obtained chemical profiles. The extracts with diethyl ether contained hydroquinone (25.8-36.8%) and 4-hydroxybenzoic acid (11.6-16.6%) as the major compounds, while ( E )-4-(r-1',t-2',c-4'-trihydroxy-2',6',6'-trimethylcyclohexyl)but-3-en-2-one predominated in dichloromethane extracts (18.3-49.1%). Therefore, combination of different solvents was crucial for the comprehensive investigation of volatile organic compounds in this honey type. This particular magastigmane was previously reported only in thymus honey and hydroquinone in vipers bugloss honey, while a combination of the mentioned predominant compounds is unique for A. ursinum honey.

  20. Solid phase microextraction of phthalic acid esters from vegetable oils using iron (III)-based metal-organic framework/graphene oxide coating.

    PubMed

    Zhang, Shuaihua; Yang, Qian; Li, Zhi; Wang, Wenjin; Zang, Xiaohuan; Wang, Chun; Wang, Zhi

    2018-10-15

    A hybrid composite featuring an iron-based metal-organic framework Material of Institute Lavoisier-88(Fe) and graphene oxide (MIL-88(Fe)/GO) was synthesized and used as the solid-phase microextraction (SPME) coating. The SPME fiber was prepared by covalent bonding of the MIL-88(Fe)/GO composite onto the stainless steel substrate. The fiber had a good durability and allowed >100 replicate extractions. The developed method, which combined the MIL-88(Fe)/GO coated fiber based SPME with gas chromatography-flame ionization detection (GC-FID), achieved low limits of detection (0.5-2.0 ng g -1 , S/N = 3) and good linearity (r 2  > 0.994) for the phthalic acid esters (PAEs) from various vegetable oil samples. The repeatability and fiber-to-fiber reproducibility were in the range of 4.0-9.1% and 5.7-11.4%, respectively. The method was successfully applied to the analysis of PAEs from vegetable oil samples with good recoveries (83.1-104.1%) and satisfactory precisions (RSDs < 10.5%), indicating that the MIL-88(Fe)/GO hybrid composite is a good coating material for the SPME of PAEs. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Solid-phase microextraction fiber development for sampling and analysis of volatile organohalogen compounds in air.

    PubMed

    Attari, Seyed Ghavameddin; Bahrami, Abdolrahman; Shahna, Farshid Ghorbani; Heidari, Mahmoud

    2014-01-01

    A green, environmental friendly and sensitive method for determination of volatile organohalogen compounds was described in this paper. The method is based on a homemade sol-gel single-walled carbon nanotube/silica composite coated solid-phase microextraction to develop for sampling and analysis of Carbon tetrachloride, Benzotrichloride, Chloromethyl methyl ether and Trichloroethylene in air. Application of this method was investigated under different laboratory conditions. Predetermined concentrations of each analytes were prepared in a home-made standard chamber and the influences of experimental parameters such as temperature, humidity, extraction time, storage time, desorption temperature, desorption time and the sorbent performance were investigated. Under optimal conditions, the use of single-walled carbon nanotube/silica composite fiber showed good performance, high sensitive and fast sampling of volatile organohalogen compounds from air. For linearity test the regression correlation coefficient was more than 98% for analyte of interest and linear dynamic range for the proposed fiber and the applied Gas Chromatography-Flame Ionization Detector technique was from 1 to 100 ngmL(-1). Method detection limits ranged between 0.09 to 0.2 ngmL(-1) and method quantification limits were between 0.25 and 0.7 ngmL(-1). Single-walled carbon nanotube/silica composite fiber was highly reproducible, relative standard deviations were between 4.3 to 11.7 percent.

  2. Combination of solid-phase extraction with dispersive liquid-liquid microextraction followed by GC-MS for determination of pesticide residues from water, milk, honey and fruit juice.

    PubMed

    Shamsipur, Mojtaba; Yazdanfar, Najmeh; Ghambarian, Mahnaz

    2016-08-01

    In this work, an effective preconcentration method for the extraction and determination of traces of multi-residue pesticides was developed using solid-phase extraction (SPE) coupled with dispersive liquid-liquid microextraction and gas chromatography-mass spectrometry (GC-MS). Variables affecting the performance of both extraction steps such as type and volume of elution and extraction solvents, breakthrough volume, salt addition, extraction time were thoroughly investigated. The proposed method resulted in good linearities (R(2)>0.9915) over the ranges of 1-10,000ngkg(-1), limits of detection (LODs) in the range of 0.5-1.0ngkg(-1) at S/N=3, and precision of RSD% of ⩽11.8. Under optimal conditions, the preconcentration factors were obtained in the range of 2362-10,593 for 100mL sample solutions. Comparison of the proposed method with other ones demonstrated that SPE-DLLME method provides higher extraction efficiency and larger preconcentration factor for determination of pesticides residues. Further, it is simple, inexpensive, highly sensitive, and can be successfully applied to separation, preconcentration and determination of the pesticides (and other noxious materials) in different real food samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Electrochemical preparation of polyaniline-polypyrrole solid-phase microextraction coating and its application in the GC determination of several esters.

    PubMed

    Zhao, Shasha; Wu, Mian; Zhao, Faqiong; Zeng, Baizhao

    2013-12-15

    A novel polyaniline-polypyrrole (PANI-PPY) composite film coated stainless steel wire was prepared by cyclic voltammetry. Firstly, PANI was electrodeposited on a stainless steel wire from a solution containing 0.1 M aniline and 1M HNO3, after the PANI coating was dried in air PPY was electrodeposited on it from a solution containing 0.1 M pyrrole and 0.1 M p-methylbenzene sulfonic acid. The resulting PANI-PPY fiber showed reticulate structure and had large specific surface area. When it was used for the headspace solid-phase microextraction of several esters (i.e. methyl anthranilate, ethyl-o-aminobenzoate, dimethyl phthalate, methyl laurate, and diethyl phthalate), followed by gas chromatographic determination, it presented higher extraction capability in comparison with PPY and PANI coatings. Under the optimized conditions, the linear ranges were 0.07-300 μg L(-1) and the detection limits were 0.05-0.38 μg L(-1) for different esters. The PANI-PPY fiber also showed high durability, after being used for about 160 times its extraction capacity only changed a little. The proposed method was successfully applied to the determination of these esters in real samples and the recoveries were 90-102%. © 2013 Elsevier B.V. All rights reserved.

  4. Graphene oxide based sol-gel stainless steel fiber for the headspace solid-phase microextraction of organophosphate ester flame retardants in water samples.

    PubMed

    Jin, Tingting; Cheng, Jing; Cai, Cuicui; Cheng, Min; Wu, Shiju; Zhou, Hongbin

    2016-07-29

    In this paper, graphene oxide was coated onto a stainless steel wire through sol-gel technique and it was used as a solid phase microextraction (SPME) fiber. The prepared fiber was characterized by scanning electron microscopy (SEM), which displayed that the fiber had crinkled surface and porous structure The application of the fiber was evaluated through the headspace SPME of nine organophosphate ester flame retardants (OPFRs) with different characteristics in water samples followed by gas chromatography and nitrogen-phosphorous detector (GC/NPD). The major factors influencing the extraction efficiency, including the extraction and desorption conditions, were studied and optimized. Under the optimum conditions, the proposed method was evaluated, and applied to the analysis of organophosphate ester flame retardants in real environmental water samples. The results demonstrated the HS-SPME method based on GO sol-gel fiber had good linearity (R>0.9928), and limits of detection (1.4-135.6ngL(-1)), high repeatability (RSD<9.8%) and good recovery (76.4-112.4%). The GO based sol-gel fiber displayed bigger extraction capability than the commercial PDMS fiber and the pure sol-gel fiber for both polar and apolar organophosphate esters, especially for the OPFRs containing benzene rings. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Novel double-confined polymeric ionic liquids as sorbents for solid-phase microextraction with enhanced stability and durability in high-ionic-strength solution.

    PubMed

    Feng, Juanjuan; Sun, Min; Xu, Lili; Wang, Shuai; Liu, Xia; Jiang, Shengxiang

    2012-12-14

    Because of the occurrence of ion exchange between high-ionic-strength solution and anions of polymeric ionic liquids (PILs), PILs based solid-phase microextraction (SPME) fibers were rarely used in direct immersion mode to high-salt-added samples. In this work, a novel double-confined PIL sorbent was prepared by co-polymerization of cation and anion of 1-vinyl-3-octylimidzaolium p-styrenesulfonate (VOIm(+)SS(-)). The poly(VOIm(+)-SS(-)) was chemically bonded onto functionalized stainless steel wire via surface radical chain-transfer reaction. Stability of poly(VOIm(+)-SS(-)) in high-ionic-strength solution was investigated and compared with that of poly(1-vinyl-3-octylimidzaolium benzenesulfonate) (poly(VOIm(+)BS(-))) by elemental analysis of sulfur element, and results turned out that the poly(VOIm(+)-SS(-)) was more stable. Coupled to gas chromatography (GC), the poly(VOIm(+)-SS(-)) fiber was used to extract three sorts of compounds including anilines, phenols and phthalate esters in aqueous solution. The as-established method showed good linearity, low detection limits, and acceptable repeatability. The direct immersion SPME-GC method was applied to determine the model phthalate esters in bottled mineral water. The determination results were satisfactory. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Solid phase microextraction field kit

    DOEpatents

    Nunes, Peter J.; Andresen, Brian D.

    2005-08-16

    A field kit for the collection, isolation and concentration of trace amounts of high explosives (HE), biological weapons (BW) and chemical weapons (CW) residues in air, soil, vegetation, swipe, and liquid samples. The field kit includes a number of Solid Phase Microextraction (SPME) fiber and syringe assemblies in a hermetically sealed transportation container or tubes which includes a sampling port, a number of extra SPME fiber and syringe assemblies, the fiber and syringe assemblies including a protective cap for the fiber, and an extractor for the protective cap, along with other items including spare parts, protective glove, and an instruction manual, all located in an airtight container.

  7. Dispersive microextraction based on water-coated Fe₃O₄ followed by gas chromatography-mass spectrometry for determination of 3-monochloropropane-1,2-diol in edible oils.

    PubMed

    Zhao, Qin; Wei, Fang; Xiao, Neng; Yu, Qiong-Wei; Yuan, Bi-Feng; Feng, Yu-Qi

    2012-06-01

    In the present work, we developed a novel dispersive microextraction technique by combining the advantages of liquid-phase microextraction (LPME) and magnetic solid-phase extraction (MSPE). In this method, trace amount of water directly absorbed on bare Fe₃O₄ to form water-coated Fe₃O₄ (W-Fe₃O₄) and rapid extraction can be achieved while W-Fe₃O₄ dispersed in the sample solution. The analyte adsorbed W-Fe₃O₄ can be easily collected and isolated from sample solution by application of a magnet. It was worth noting that in the proposed method water was used as extractant and Fe₃O₄ served as the supporter and retriever of water. The performance of the method was evaluated by extraction of 3-monochloropropane-1,2-diol (3-MCPD) from edible oils. The extracted 3-MCPD was then derived by a silylanization reagent (1-trimethylsilylimidazole) before gas chromatography-mass spectrometry (GC-MS) analysis. Several parameters that affected the extraction and derivatization efficiency were investigated. Our results showed that the limit of detection for 3-MCPD was 1.1 ng/g. The recoveries in spiked oil samples were in the range of 70.0-104.9% with the RSDs less than 5.6% (intra-day) and 6.4% (inter-day). Taken together, the simple, rapid and cost-effective method developed in current study, offers a potential application for the extraction and preconcentration of hydrophilic analytes from complex fatty samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Integrated atomic layer deposition and chemical vapor reaction for the preparation of metal organic framework coatings for solid-phase microextraction Arrow.

    PubMed

    Lan, Hangzhen; Salmi, Leo D; Rönkkö, Tuukka; Parshintsev, Jevgeni; Jussila, Matti; Hartonen, Kari; Kemell, Marianna; Riekkola, Marja-Liisa

    2018-09-18

    New chemical vapor reaction (CVR) and atomic layer deposition (ALD)-conversion methods were utilized for preparation of metal organic frameworks (MOFs) coatings of solid phase microextraction (SPME) Arrow for the first time. With simple, easy and convenient one-step reaction or conversion, four MOF coatings were made by suspend ALD iron oxide (Fe 2 O 3 ) film or aluminum oxide (Al 2 O 3 ) film above terephthalic acid (H 2 BDC) or trimesic acid (H 3 BTC) vapor. UIO-66 coating was made by zirconium (Zr)-BDC film in acetic acid vapor. As the first documented instance of all-gas phase synthesis of SPME Arrow coatings, preparation parameters including CVR/conversion time and temperature, acetic acid volume, and metal oxide film/metal-ligand films thickness were investigated. The optimal coatings exhibited crystalline structures, excellent uniformity, satisfactory thickness (2-7.5 μm), and high robustness (>80 times usage). To study the practical usefulness of the coatings for the extraction, several analytes with different chemical properties were tested. The Fe-BDC coating was found to be the most selective and sensitive for the determination of benzene ring contained compounds due to its highly hydrophobic surface and unsaturated metal site. UIO-66 coating was best for small polar, aromatic, and long chain polar compounds owing to its high porosity. The usefulness of new coatings were evaluated for gas chromatography-mass spectrometer (GC-MS) determination of several analytes, present in wastewater samples at three levels of concentration, and satisfactory results were achieved. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. A low-cost biosorbent-based coating for the highly sensitive determination of organochlorine pesticides by solid-phase microextraction and gas chromatography-electron capture detection.

    PubMed

    do Carmo, Sângela Nascimento; Merib, Josias; Dias, Adriana Neves; Stolberg, Joni; Budziak, Dilma; Carasek, Eduardo

    2017-11-24

    In this study, an environmentally friendly and low-cost biosorbent coating was evaluated, for the first time, as the extraction phase for solid-phase microextraction (SPME) supported on a nitinol alloy. The characterization of the new fiber was performed by Fourier transform infrared spectroscopy (FTIR), thermogravimetric analysis (TGA) and scanning electron microscopy (SEM). The applicability of the biosorbent-based fiber in the determination of δ-hexachlorocyclohexane, aldrin, heptachlor epoxide, α-endosulfan, endrin and 4,4'-DDD in water samples was verified, with separation/detection by gas chromatography coupled to electron capture detection (GC-ECD). The influencing parameters (temperature, extraction time and ionic strength) were optimized simultaneously using a central composite design. The optimum conditions were: extraction time of 80min at 80°C and sodium chloride concentration of 15% (w/v). Satisfactory analytical performance was achieved with limits of detection (LOD) between 0.19 and 0.71ngL -1 and limits of quantification (LOQ) between 0.65 and 2.38ngL -1 . The relative recoveries for the analytes were determined using river and lake water samples spiked at different concentrations and ranged from 60% for α-endosulfan to 113% for δ-hexachlorocyclohexane, with relative standard deviations (RSD) lower than 21%. The fiber-to-fiber reproducibility (n=3) was also evaluated and the RSD was lower than 14%. The extraction efficiency obtained for the proposed biosorbent coating was compared to a commercially available DVB/Car/PDMS coating. The proposed fiber provided very promising results, including LODs at the level of parts per trillion and highly satisfactory thermal and mechanical stability. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Preparation and characterization of citral-loaded solid lipid nanoparticles.

    PubMed

    Tian, Huaixiang; Lu, Zhuoyan; Li, Danfeng; Hu, Jing

    2018-05-15

    Citral-loaded solid lipid nanoparticles (citral-SLNs) were prepared via a high-pressure homogenization method, using glyceryl monostearate (GMS) as the solid lipid and a mixture of Tween 80 (T-80) and Span 80 (S-80) at a weight ratio of 1:1 as the surfactant. The microstructure and properties of the citral-SLNs were characterized by dynamic light scattering (DLS), scanning electron microscopy (SEM), differential scanning calorimetry (DSC), Fourier-transform infrared spectroscopy (FTIR), X-ray diffraction (XRD) and thermal gravimetric analysis (TGA). The chemical stability of citral in the citral-SLNs was analyzed by solid-phase microextraction gas chromatography (SPME-GC). The GC results showed that 67.0% of the citral remained in the citral-SLN suspensions after 12 days, while only 8.22% remained in the control. Therefore, the encapsulation of citral in the solid lipid can enhance its stability in acidic surroundings. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. [Analyze on volatile compounds of Antrodia camphorata using HS-SPME-GC-MS].

    PubMed

    He, Zhe; Lu, Zhen-Ming; Xu, Hong-Yu; Shi, Jing-Song; Xu, Zheng-Hong

    2011-11-01

    To analyze the volatile compounds of Antrodia camphorata in solid-state and submerged cultures. A headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography-mass spectrometry(GC-MS) were used to evaluate the profile of the volatile compounds. 49 volatile compounds were identified in A. camphorata mycelia in submerged culture, while 43 volatile compounds were identified in mycelia in solid-state culture. 1-octen-3-ol, 3-octanone, 1-octen-3-ylacetate, acetic acid octyl ester and ethanol were the main volatile compounds in A. camphorata mycelia in submerged culture, while 1-octen-3-ol, 3-octanone, 3-methyl-butyraldenhyde, gamma-podecalactone and methyl 2-furozte were the most potent key volatile compounds in mycelia in solid-state culture. The volatile compounds in the mycelia of A. camphorata in solid-state and submerged cultures are similar but their relative contents are different.

  12. High-temperature solid-phase microextraction procedure for the detection of drugs by gas chromatography-mass spectrometry.

    PubMed

    Staerk, U; Külpmann, W R

    2000-08-18

    High-temperature headspace solid-phase microextraction (SPME) with simultaneous ("in situ") derivatisation (acetylation or silylation) is a new sample preparation technique for the screening of illicit drugs in urine and for the confirmation analysis in serum by GC-MS. After extraction of urine with a small portion of an organic solvent mixture (e.g., 2 ml of hexane-ethyl acetate) at pH 9, the organic layer is separated and evaporated to dryness in a small headspace vial. A SPME-fiber (e.g., polyacrylate) doped with acetic anhydride-pyridine (for acetylation) is exposed to the vapour phase for 10 min at 200 degrees C in a blockheater. The SPME fiber is then injected into the GC-MS for thermal desorption and analysis. After addition of perchloric acid and extraction with n-hexane to remove lipids, the serum can be analysed after adjusting to pH 9 as described for urine. Very clean extracts are obtained. The various drugs investigated could be detected and identified in urine by the total ion current technique at the following concentrations: amphetamines (200 microg/l), barbiturates (500 microg/l), benzodiazepines (100 microg/l), benzoylecgonine (150 microg/l), methadone (100 microg/l) and opiates (200 microg/l). In serum all drugs could be detected by the selected ion monitoring technique within their therapeutic range. As compared to liquid-liquid extraction only small amounts of organic solvent are needed and larger amounts of the pertinent analytes could be transferred to the GC column. In contrast to solid-phase extraction (SPE), the SPME-fiber is reusable several times (as there is no contamination by endogenous compounds). The method is time-saving and can be mechanised by the use of a dedicated autosampler.

  13. Preparation of novel alumina nanowire solid-phase microextraction fiber coating for ultra-selective determination of volatile esters and alcohols from complicated food samples.

    PubMed

    Zhang, Zhuomin; Ma, Yunjian; Wang, Qingtang; Chen, An; Pan, Zhuoyan; Li, Gongke

    2013-05-17

    A novel alumina nanowire (ANW) solid-phase microextraction (SPME) fiber coating was prepared by a simple and rapid anodization-chemical etching method for ultra-selective determination of volatile esters and alcohols from complicated food samples. Preparation conditions for ANW SPME fiber coating including corrosion solution concentration and corrosion time were optimized in detail for better surface morphology and higher surface area based on scanning electron microscope (SEM). Under the optimum conditions, homogeneous alumina nanowire structure of ANW SPME fiber coating was achieved with the average thickness of 20 μm around. Compared with most of commercial SPME fiber coatings, ANW SPME fiber coatings achieved the higher extraction capacity and special selectivity for volatile esters and alcohols. Finally, an efficient gas sampling technique based on ANW SPME fiber coating as the core was established and successfully applied for the ultra-selective determination of trace volatile esters and alcohols from complicated banana and fermented glutinous rice samples coupled with gas chromatography/mass spectrometry (GC/MS) detection. It was interesting that 25 esters and 2 alcohols among 30 banana volatile organic compounds (VOCs) identified and 4 esters and 7 alcohols among 13 identified VOCs of fermented glutinous rice were selectively sampled by ANW SPME fiber coatings. Furthermore, new analytical methods for the determination of some typical volatile esters and alcohols from banana and fermented glutinous rice samples at specific storage or brewing phases were developed and validated. Good recoveries for banana and fermented glutinous rice samples were achieved in range of 108-115% with relative standard deviations (RSDs) of 2.6-6.7% and 80.0-91.8% with RSDs of 0.3-1.3% (n=3), respectively. This work proposed a novel and efficient gas sampling technique of ANW SPME which was quite suitable for ultra-selectively sampling trace volatile esters and alcohols from complicated food samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Chromatographic analysis of methylglyoxal and other α-dicarbonyls using gas-diffusion microextraction.

    PubMed

    Santos, Christiane M; Valente, Inês M; Gonçalves, Luís M; Rodrigues, José A

    2013-12-07

    Many α-dicarbonyl compounds such as methylglyoxal, diacetyl and pentane-2,3-dione are important quality markers of processed foods. They are produced by enzymatic and chemical processes, the Maillard reaction is the most known chemical route for α-dicarbonyl formation. In the case of methylglyoxal, there are obstacles to be overcome when analysing this compound due to its high reactivity, low volatility and low concentration. The use of extraction techniques based on the volatilization of methylglyoxal (like solid-phase microextraction) showed to be ineffective for the methylglyoxal extraction from aqueous solutions. Therefore, derivatization is typically applied to increase analyte's volatility. In this work a new methodology for the extraction and analysis of methylglyoxal and also diacetyl and pentane-2,3-dione from selected food matrices is presented. It is based on a gas-diffusion microextraction step followed by high performance liquid chromatographic analysis. It was successfully applied to port wines, black tea and soy sauce. Methylglyoxal, diacetyl and pentane-2,3-dione were quantified in the following concentration ranges: 0.24-1.74 mg L(-1), 0.1-1.85 mg L(-1) and 0.023-0.15 mg L(-1), respectively. The main advantages over existing methodologies are its simplicity in terms of sample handling, not requiring any chemical modification of the α-dicarbonyls prior to the extraction, low reagent consumption and short time of analysis.

  15. Rapid and sensitive analysis of polychlorinated biphenyls and acrylamide in food samples using ionic liquid-based in situ dispersive liquid-liquid microextraction coupled to headspace gas chromatography.

    PubMed

    Zhang, Cheng; Cagliero, Cecilia; Pierson, Stephen A; Anderson, Jared L

    2017-01-20

    A simple and rapid ionic liquid (IL)-based in situ dispersive liquid-liquid microextraction (DLLME) method was developed and coupled to headspace gas chromatography (HS-GC) employing electron capture (ECD) and mass spectrometry (MS) detection for the analysis of polychlorinated biphenyls (PCBs) and acrylamide at trace levels from milk and coffee samples. The chemical structures of the halide-based ILs were tailored by introducing various functional groups to the cations to evaluate the effect of different structural features on the extraction efficiency of the target analytes. Extraction parameters including the molar ratio of IL to metathesis reagent and IL mass were optimized. The effects of HS oven temperature and the HS sample vial volume on the analyte response were also evaluated. The optimized in situ DLLME method exhibited good analytical precision, good linearity, and provided detection limits down to the low ppt level for PCBs and the low ppb level for acrylamide in aqueous samples. The matrix-compatibility of the developed method was also established by quantifying acrylamide in brewed coffee samples. This method is much simpler and faster compared to previously reported GC-MS methods using solid-phase microextraction (SPME) for the extraction/preconcentration of PCBs and acrylamide from complex food samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Simultaneous determination of selegiline and desmethylselegiline in human body fluids by headspace solid-phase microextraction and gas chromatography-mass spectrometry.

    PubMed

    Kuriki, Ayako; Kumazawa, Takeshi; Lee, Xiao-Pen; Hasegawa, Chika; Kawamura, Mitsuru; Suzuki, Osamu; Sato, Keizo

    2006-12-05

    A method for the simultaneous determination of selegiline and its metabolite, desmethylselegiline, in human whole blood and urine is presented. The method, which combines a fiber-based headspace solid-phase microextraction (SPME) technique with gas chromatography-mass spectrometry (GC-MS), required optimization of various parameters (e.g., salt additives, extraction temperatures, extraction times and the extraction properties of the SPME fiber coatings). Pargyline was used as the internal standard. Extraction efficiencies for both selegiline and desmethylselegiline were 2.0-3.4% for whole blood, and 8.0-13.2% for urine. The regression equations for selegiline and desmethylselegiline extracted from whole blood were linear (r(2)=0.996 and 0.995) within the concentration ranges 0.1-10 and 0.2-20 ng/ml, respectively. For urine, the regression equations for selegiline and desmethylselegiline were linear (r(2)=0.999 and 0.998) within the concentration ranges 0.05-5.0 and 0.1-10 ng/ml, respectively. The limit of detection for selegiline and desmethylselegiline was 0.01-0.05 ng/ml for both samples. The lower and upper limits of quantification for each compound were 0.05-0.2 and 5-20 ng/ml, respectively. Intra- and inter-day coefficients of variation for selegiline and desmethylselegiline in both samples were not greater than 8.7 and 11.7%, respectively. The determination of selegiline and desmethylselegiline concentrations in Parkinson's disease patients undergoing continuous selegiline treatment is presented and is shown to validate the present methodology.

  17. Field Analysis of Polychlorinated Biphenyls (PCBs) in Soil Using Solid-Phase Microextraction (SPME) and a Portable Gas Chromatography-Mass Spectrometry System.

    PubMed

    Zhang, Mengliang; Kruse, Natalie A; Bowman, Jennifer R; Jackson, Glen P

    2016-05-01

    An expedited field analysis method was developed for the determination of polychlorinated biphenyls (PCBs) in soil matrices using a portable gas chromatography-mass spectrometry (GC-MS) instrument. Soil samples of approximately 0.5 g were measured with a portable scale and PCBs were extracted by headspace solid-phase microextraction (SPME) with a 100 µm polydimethylsiloxane (PDMS) fiber. Two milliliters of 0.2 M potassium permanganate and 0.5 mL of 6 M sulfuric acid solution were added to the soil matrices to facilitate the extraction of PCBs. The extraction was performed for 30 min at 100 ℃ in a portable heating block that was powered by a portable generator. The portable GC-MS instrument took less than 6 min per analysis and ran off an internal battery and helium cylinder. Six commercial PCB mixtures, Aroclor 1016, 1221, 1232, 1242, 1248, 1254, and 1260, could be classified based on the GC chromatograms and mass spectra. The detection limit of this method for Aroclor 1260 in soil matrices is approximately 10 ppm, which is sufficient for guiding remediation efforts in contaminated sites. This method was applicable to the on-site analysis of PCBs with a total analysis time of 37 min per sample. However, the total analysis time could be improved to less than 7 min per sample by conducting the rate-limiting extraction step for different samples in parallel. © The Author(s) 2016.

  18. Determination of caffeine, myosmine, and nicotine in chocolate by headspace solid-phase microextraction coupled with gas chromatography-tandem mass spectrometry.

    PubMed

    Müller, Christoph; Vetter, Florian; Richter, Elmar; Bracher, Franz

    2014-02-01

    The occurrence of the bioactive components caffeine (xanthine alkaloid), myosmine and nicotine (pyridine alkaloids) in different edibles and plants is well known, but the content of myosmine and nicotine is still ambiguous in milk/dark chocolate. Therefore, a sensitive method for determination of these components was established, a simple separation of the dissolved analytes from the matrix, followed by headspace solid-phase microextraction coupled with gas chromatography-tandem mass spectrometry (HS-SPME-GC-MS/MS). This is the first approach for simultaneous determination of caffeine, myosmine, and nicotine with a convenient SPME technique. Calibration curves were linear for the xanthine alkaloid (250 to 3000 mg/kg) and the pyridine alkaloids (0.000125 to 0.003000 mg/kg). Residuals of the calibration curves were lower than 15%, hence the limits of detection were set as the lowest points of the calibration curves. The limits of detection calculated from linearity data were for caffeine 216 mg/kg, for myosmine 0.000110 mg/kg, and for nicotine 0.000120 mg/kg. Thirty samples of 5 chocolate brands with varying cocoa contents (30% to 99%) were analyzed in triplicate. Caffeine and nicotine were detected in all samples of chocolate, whereas myosmine was not present in any sample. The caffeine content ranged from 420 to 2780 mg/kg (relative standard deviation 0.1 to 11.5%) and nicotine from 0.000230 to 0.001590 mg/kg (RSD 2.0 to 22.1%). © 2014 Institute of Food Technologists®

  19. Neuro-genetic multioptimization of the determination of polychlorinated biphenyl congeners in human milk by headspace solid phase microextraction coupled to gas chromatography with electron capture detection.

    PubMed

    Kowalski, Cláudia Hoffmann; da Silva, Gilmare Antônia; Poppi, Ronei Jesus; Godoy, Helena Teixeira; Augusto, Fabio

    2007-02-28

    Polychlorinated biphenyls (PCB) can eventually contaminate breast milk, which is a serious issue to the newborn due to their high vulnerability. Solid phase microextraction (SPME) can be a very convenient technique for their isolation and pre-concentration prior chromatographic analysis. Here, a simultaneous multioptimization strategy based on a neuro-genetic approach was applied to a headspace SPME method for determination of 12 PCB in human milk. Gas chromatography with electron capture detection (ECD) was adopted for the separation and detection of the analytes. Experiments according to a Doehlert design were carried out with varied extraction time and temperature, media ionic strength and concentration of the methanol (co-solvent). To find the best model that simultaneously correlate all PCB peak areas and SPME extraction conditions, a multivariate calibration method based on a Bayesian Neural Network (BNN) was applied. The net output from the neural network was used as input in a genetic algorithm (GA) optimization operation (neuro-genetic approach). The GA pointed out that the best values of the overall SPME operational conditions were the saturation of the media with NaCl, extraction temperature of 95 degrees C, extraction time of 60 min and addition of 5% (v/v) methanol to the media. These optimized parameters resulted in the decrease of the detection limits and increase on the sensitivity for all tested analytes, showing that the use of neuro-genetic approach can be a promising way for optimization of SPME methods.

  20. Polypyrrole/montmorillonite nanocomposite as a new solid phase microextraction fiber combined with gas chromatography-corona discharge ion mobility spectrometry for the simultaneous determination of diazinon and fenthion organophosphorus pesticides.

    PubMed

    Jafari, Mohammad T; Saraji, Mohammad; Sherafatmand, Hossein

    2014-03-03

    A novel solid phase microextraction (SPME) fiber was prepared and coupled with gas chromatography corona discharge ion mobility spectrometry (GC-CD-IMS) based on polypyrrole/montmorillonite nanocomposites for the simultaneous determination of diazinon and fenthion. The nanocomposite polymer was coated using a three-electrode electrochemical system and directly deposited on a Ni-Cr wire by applying a constant potential. The scanning electron microscopy images revealed that the new fiber exhibited a rather porous and homogenous surface. The thermal stability of the fabricated fiber was investigated by thermogravimetric analysis. The effects of different parameters influencing the extraction efficiency such as extraction temperature and time, salt addition, stirring rate, the amount of nanoclay, and desorption temperature were investigated and optimized. The method was exhaustively evaluated in terms of sensitivity, recovery, and reproducibility. The linearity ranges of 0.05-10 and 0.08-10 μg L(-1), and the detection limits of 0.020 and 0.035 μg L(-1) were obtained for diazinon and fenthion, respectively. The relative standard deviation values were calculated to be lower than 5% and 8% for intra-day and inter-day, respectively. Finally, the developed method was applied to determine the diazinon and fenthion (as model compounds) in cucumber, lettuce, apple, tap and river water samples. The satisfactory recoveries revealed the capability of the two-dimensional separation technique (retention time in GC and drift time in IMS) for the analysis of complex matrices extracted by SPME. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Photodegradation of crude oil: liquid injection and headspace solid-phase microextraction for crude oil analysis by gas chromatography with mass spectrometer detector.

    PubMed

    D'Auria, Maurizio; Racioppi, Rocco; Velluzzi, Vincenzina

    2008-04-01

    The fate of crude oil under irradiation is studied. After UV irradiation, the fraction present in the highest percentage shifts from the C8-C9 fractions to C13, using gas chromatography-mass spectrometry (GC-MS) analysis in solution. An increase of the relative amount of the C13-C25 fraction is observed, while a decrease in the relative amount of the C7-C12 fractions is present. In headspace solid-phase microextraction (HS-SPME) analysis, the C8-C10 fractions represent 53% of all the compounds detected. A decrease in the relative amount of the C8-C10 fractions is observed, while C11-C15 fractions increase. The irradiation of crude oil with a solar simulator gives a mixture the analysis of which using GC-MS in solution furnishes the same type of results: the relative amounts of linear alkanes and aromatic compounds increase, while a sharp decrease in the relative amounts of branched and cyclic alkanes is observed. In the SPME analysis, a decreased relative amount of branched alkanes and alkenes, and an increase in the relative amounts of cyclic alkanes and aromatic compounds are observed. Analysis of the distribution of the compounds in all the types of compound shows that a dynamic equilibrium between different compounds and different types of compounds is present. To confirm the presence of a dynamic equilibrium, the irradiation of methylcyclohexane in the presence of 2-methylnaphthalene shows the presence in the reaction mixture of a small amount of tetradecane.

  2. Coupling of headspace solid phase microextraction with ultrasonic extraction for the determination of chlorinated pesticides in bird livers using gas chromatography.

    PubMed

    Lambropoulou, Dimitra A; Konstantinou, Ioannis K; Albanis, Triantafyllos A

    2006-07-28

    In the present study a combined analytical method involving ultrasonic extraction (USE), sulfuric acid clean-up and headspace solid-phase microextraction (HS-SPME) was developed for the determination of chlorinated pesticides (CPs) in bird livers. Extraction of CPs from 1g of liver was performed by ultrasonication for 30 min using 20 mL of solvent mixture (n-hexane:acetone (4:1, v/v)). The extract was subsequently subjected to a clean-up step for lipid removal. A comparative study on several clean-up procedures prior to the HS-SPME enrichment step was performed in order to achieve maximum recovery and optimal clean-up efficiency, which would provide suitable limits of detection in the gas chromatographic analysis. For this purpose, destructive (sulfuric acid or sodium hydroxide treatment) and non-destructive (alumina column) clean-up procedures has been assayed. The treatment of the extract with 40% (v/v) H2SO4 prior to HS-SPME process showed the best performance since lower detection limits and higher extraction efficiencies were obtained. The method detection limit ranged from 0.5 to 1.0 ng g(-1) wet weight and peak areas were proportional to analyte concentrations (r2>0.990) in the range of 5-500 ng g(-1) wet wt. The method was found to be reproducible (R.S.D.<10%) and effective under the operational conditions proposed and was applied successfully to the analysis of CPs in liver tissues of various bird species from Greece.

  3. Study of the aroma formation and transformation during the manufacturing process of oolong tea by solid-phase micro-extraction and gas chromatography-mass spectrometry combined with chemometrics.

    PubMed

    Ma, Chengying; Li, Junxing; Chen, Wei; Wang, Wenwen; Qi, Dandan; Pang, Shi; Miao, Aiqing

    2018-06-01

    Oolong tea is a typical semi-fermented tea and is famous for its unique aroma. The aim of this study was to compare the volatile compounds during manufacturing process to reveal the formation of aroma. In this paper, a method was developed based on head-space solid phase microextraction/gas chromatography-mass spectrometry (HS-SPME/GC-MS) combined with chemometrics to assess volatile profiles during manufacturing process (fresh leaves, sun-withered leaves, rocked leaves and leaves after de-enzyming). A total of 24 aroma compounds showing significant differences during manufacturing process were identified. Subsequently, according to these aroma compounds, principal component analysis and hierarchical cluster analysis showed that the four samples were clearly distinguished from each other, which suggested that the 24 identified volatile compounds can represent the changes of volatile compounds during the four steps. Additionally, sun-withering, rocking and de-enzyming can influence the variations of volatile compounds in different degree, and we found the changes of volatile compounds in withering step were less than other two manufacturing process, indicating that the characteristic volatile compounds of oolong tea might be mainly formed in rocking stage by biological reactions and de-enzyming stage through thermal chemical transformations rather than withering stage. This study suggested that HS-SPME/GC-MS combined with chemometrics methods is accurate, sensitive, fast and ideal for rapid routine analysis of the aroma compounds changes in oolong teas during manufacturing processing. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. Determination of organophosphorus flame retardants in fish by pressurized liquid extraction using aqueous solutions and solid-phase microextraction coupled with gas chromatography-flame photometric detector.

    PubMed

    Gao, Zhanqi; Deng, Yuehua; Yuan, Wenting; He, Huan; Yang, Shaogui; Sun, Cheng

    2014-10-31

    A novel method was developed for the determination of organophosphorus flame retardants (PFRs) in fish. The method consists of a combination of pressurized liquid extraction (PLE) using aqueous solutions and solid-phase microextraction (SPME), followed by gas chromatography-flame photometric detector (GC-FPD). The experimental parameters that influenced extraction efficiency were systematically evaluated. The optimal responses were observed by extracting 1g of fish meat with the solution of water:acetonitrile (90:10, v/v) at 150°C for 5min and acid-washed silica gel used as lipid sorbent. The obtained extract was then analyzed by SPME coupled with GC-FPD without any additional clean-up steps. Under the optimal conditions, the proposed procedure showed a wide linear range (0.90-5000ngg(-1)) obtained by analyzing the spiked fish samples with increasing concentrations of PFRs and correlation coefficient (R) ranged from 0.9900 to 0.9992. The detection limits (S/N=3) were in the range of 0.010-0.208ngg(-1) with standard deviations (RSDs) ranging from 2.0% to 9.0%. The intra-day and inter-day variations were less than 9.0% and 7.8%, respectively. The proposed method was successfully applied to the determination of PFRs in real fish samples with recoveries varying from 79.8% to 107.3%. The results demonstrate that the proposed method is highly effective for analyzing PFRs in fish samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Emission pattern of semi-volatile organic compounds from recycled styrenic polymers using headspace solid-phase microextraction gas chromatography-mass spectrometry.

    PubMed

    Vilaplana, Francisco; Martínez-Sanz, Marta; Ribes-Greus, Amparo; Karlsson, Sigbritt

    2010-01-15

    The emission of low molecular weight compounds from recycled high-impact polystyrene (HIPS) has been investigated using headspace solid-phase microextraction (HS-SPME) and gas chromatography-mass spectrometry (GC-MS). Four released target analytes (styrene, benzaldehyde, acetophenone, and 2-phenylpropanal) were selected for the optimisation of the HS-SPME sampling procedure, by analysing operating parameters such as type of SPME fibre (polarity and operating mechanism), particle size, extraction temperature and time. 26 different compounds were identified to be released at different temperatures from recycled HIPS, including residues of polymerisation, oxidated derivates of styrene, and additives. The type of SPME fibre employed in the sampling procedure affected the detection of emitted components. An adsorptive fibre such as carbowax/polydimethylsiloxane (CAR/PDMS fibre) offered good selectivity for both non-polar and polar volatile compounds at lower temperatures; higher temperatures result in interferences from less-volatile released compounds. An absorptive fibre as polydimethylsiloxane (PDMS) fibre is suitable for the detection of less-volatile non-polar molecules at higher temperatures. The nature and relative amount of the emitted compounds increased with higher exposure temperature and smaller polymeric particle size. HS-SPME proves to be a suitable technique for screening the emission of semi-volatile organic compounds (SVOCs) from polymeric materials; reliable quantification of the content of target analytes in recycled HIPS is however difficult due to the complex mass-transfer processes involved, matrix effects, and the difficulties in equilibrating the analytical system. 2009 Elsevier B.V. All rights reserved.

  6. Study of chemical stability of lemon oil components in sodium caseinate-lactose glycoconjugate-stabilized oil-in-water emulsions using solid-phase microextraction-gas chromatography.

    PubMed

    Sabik, Hassan; Achouri, Allaoua; Alfaro, Maria; Pelletier, Marylène; Belanger, Denis; Britten, Michel; Fustier, Patrick

    2014-07-25

    A headspace solid-phase microextraction (HS-SPME) combined with gas chromatography-mass spectrometry (GC/MS) method was developed to quantify lemon oil components and their degradation products in oil-in-water (O/W) emulsions prepared with sodium caseinate-heated-lactose (NaC-T + Lact) glycoconjugates as wall materials at two pH values (3.0 and 6.8). NaC-T + Lact conjugates had a significantly lower solubility at both pHs. Hydrolysis prior to glycation enhanced the solubility of glycoconjugates. Glycation with lactose did not improve the emulsion activity of NaC, while caseinate glycoconjugates showed much stronger antioxidant activity than the NaC-control sample. This might be due to the presence of melanoidins formed between the sugar and amino acid compounds as supported by the increase in browning intensity. Among the SPME-fibres tested, carboxen/polydimethylsiloxane (CAR/PDMS) provided better results in terms of sensitivity and selectivity for oil lemon components and their degradation products. Storage studies of these emulsions demonstrated that glycated NaC-T + Lact showed protection against peroxidation compared to the control. However, acidic pH conditions altered their stability over storage time. The major off-flavor components (α-terpineol and carvone) were inhibited in emulsions stabilized with glycated NaC, particularly at pH 6.8. The use of NaC-T + Lact conjugates showed improved encapsulation efficiency and stability and could be used as potential food ingredient-emulsifiers for stabilising citrus oils against oxidative degradation in food and beverage applications.

  7. A review on development of solid phase microextraction fibers by sol-gel methods and their applications.

    PubMed

    Kumar, Ashwini; Gaurav; Malik, Ashok Kumar; Tewary, Dhananjay Kumar; Singh, Baldev

    2008-03-03

    Solid phase microextraction (SPME) is an innovative, solvent free technology that is fast, economical and versatile. SPME is a fiber coated with a liquid (polymer), a solid (sorbent) or a combination of both. The fiber coating takes up the compounds from the sample by absorption in the case of liquid coatings or adsorption in the case of solid coatings. The SPME fiber is then transferred with the help of a syringe like device into the analytical instrument for desorption and analysis of the target analytes. The sol-gel process provides a versatile method to prepare size, shape and charge selective materials of high purity and homogeneity by means of preparation techniques different from the traditional ones, for the chemical analysis. This review is on the current state of the art and future trends in the developments of solid phase microextraction (SPME) fibers using sol-gel method. To achieve more selective determination of different compound classes, the variety of different coating material for SPME fibers has increased. Further developments in SPME as a highly efficient extraction technique, will greatly depend on new breakthroughs in the area of new coating material developments for the SPME fibers. In sol-gel approach, appropriate sol-gel precursors and other building blocks can be selected to create a stationary phase with desired structural and surface properties. This approach is efficient in integrating the advantageous properties of organic and inorganic material systems and thereby increasing and improving the extraction selectivity of the produced amalgam organic-inorganic stationary phases. This review is mainly focused on recent advanced developments in the design, synthesis, characterisation, properties and application of sol-gel in preparation of coatings for the SPME fibers.

  8. Method and apparatus for optimized sampling of volatilizable target substances

    DOEpatents

    Lindgren, Eric R.; Phelan, James M.

    2004-10-12

    An apparatus for capturing, from gases such as soil gas, target analytes. Target analytes may include emanations from explosive materials or from residues of explosive materials. The apparatus employs principles of sorption common to solid phase microextraction, and is best used in conjunction with analysis means such as a gas chromatograph. To sorb target analytes, the apparatus functions using various sorptive structures to capture target analyte. Depending upon the embodiment, those structures may include a capillary tube including an interior surface on which sorptive material (similar to that on the surface of a SPME fiber) is supported (along with means for moving gases through the capillary tube so that the gases come into close proximity to the sorptive material). In one disclosed embodiment, at least one such sorptive structure is associated with an enclosure including an opening in communication with the surface of a soil region potentially contaminated with buried explosive material such as unexploded ordnance. Emanations from explosive materials can pass into and accumulate in the enclosure where they are sorbed by the sorptive structures. Also disclosed is the use of heating means such as microwave horns to drive target analytes into the soil gas from solid and liquid phase components of the soil.

  9. Physically incorporated extraction phase of solid-phase microextraction by sol-gel technology.

    PubMed

    Liu, Wenmin; Hu, Yuan; Zhao, Jinghong; Xu, Yuan; Guan, Yafeng

    2006-01-13

    A sol-gel method for the preparation of solid-phase microextraction (SPME) fiber was described and evaluated. The extraction phase of poly(dimethysiloxane) (PDMS) containing 3% vinyl group was physically incorporated into the sol-gel network without chemical bonding. The extraction phase itself is then partly crosslinked at 320 degrees C, forming an independent polymer network and can withstand desorption temperature of 290 degrees C. The headspace extraction of BTX by the fiber SPME was evaluated and the detection limit of o-xylene was down to 0.26 ng/l. Extraction and determination of organophosphorus pesticides (OPPs) in water, orange juice and red wine by the SPME-GC thermionic specified detector (TSD) was validated. Limits of detection of the method for OPPs were below 10 ng/l except methidathion. Relative standard deviations (RSDs) were in the range of 1-20% for pesticides being tested.

  10. Bis(trifluoromethanesulfonyl)imide-based ionic liquids grafted on graphene oxide-coated solid-phase microextraction fiber for extraction and enrichment of polycyclic aromatic hydrocarbons in potatoes and phthalate esters in food-wrap.

    PubMed

    Hou, Xiudan; Guo, Yong; Liang, Xiaojing; Wang, Xusheng; Wang, Lei; Wang, Licheng; Liu, Xia

    2016-06-01

    A class of novel, environmental friendly ionic liquids (ILs) were synthesized by on-fiber preparation strategy and modified on graphene oxide (GO)-coated stainless steel wire, which was used as a solid-phase microextraction (SPME) fiber for efficient enrichment of polycyclic aromatic hydrocarbons (PAHs) and phthalate esters (PAEs). Surface characteristic of the ILs and polymeric-ILs (PILs) fibers with the wave-structure were inspected by scanning electron microscope. The successfully synthesis of bis(trifluoromethanesulfonyl)imide (NTf2(-))-based ILs were also characterized by energy dispersive spectrometer analysis. Through the chromatograms of the proposed two ILs (1-aminoethyl-3-methylimidazolium bromide (C2NH2MIm(+)Br(-)), C2NH2MIm(+)NTf2(-)) and two PILs (polymeric 1-vinyl-3-hexylimidazolium bromide (poly(VHIm(+)Br(-))), poly(VHIm(+)NTf2(-)))-GO-coated fibers for the extraction of analytes, NTf2(-)-based PIL demonstrated higher extraction capacity for hydrophobic compounds than other as-prepared ILs. Analytical performances of the proposed fibers were investigated under the optimized extraction and desorption conditions coupled with gas chromatography (GC). Compared with the poly(VHIm(+)Br(-))-GO fiber, the poly(VHIm(+)NTf2(-))-GO SPME fiber brought wider linear ranges for analytes with correlation coefficient in the range of 0.9852-0.9989 and lower limits of detection ranging from 0.015-0.025μgL(-1). The obtained results indicated that the newly prepared PILs-GO coating was a feasible, selective and green microextraction medium, which could be suitable for extraction and determination of PAHs and PAEs in potatoes and food-wrap sample, respectively. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Static SPME sampling of VOCs emitted from indoor building materials: prediction of calibration curves of single compounds for two different emission cells.

    PubMed

    Mocho, Pierre; Desauziers, Valérie

    2011-05-01

    Solid-phase microextraction (SPME) is a powerful technique, easy to implement for on-site static sampling of indoor VOCs emitted by building materials. However, a major constraint lies in the establishment of calibration curves which requires complex generation of standard atmospheres. Thus, the purpose of this paper is to propose a model to predict adsorption kinetics (i.e., calibration curves) of four model VOCs. The model is based on Fick's laws for the gas phase and on the equilibrium or the solid diffusion model for the adsorptive phase. Two samplers (the FLEC® and a home-made cylindrical emission cell), coupled to SPME for static sampling of material emissions, were studied. A good agreement between modeling and experimental data is observed and results show the influence of sampling rate on mass transfer mode in function of sample volume. The equilibrium model is adapted to quite large volume sampler (cylindrical cell) while the solid diffusion model is dedicated to small volume sampler (FLEC®). The limiting steps of mass transfer are the diffusion in gas phase for the cylindrical cell and the pore surface diffusion for the FLEC®. In the future, this modeling approach could be a useful tool for time-saving development of SPME to study building material emission in static mode sampling.

  12. Sample preparation techniques for the determination of trace residues and contaminants in foods.

    PubMed

    Ridgway, Kathy; Lalljie, Sam P D; Smith, Roger M

    2007-06-15

    The determination of trace residues and contaminants in complex matrices, such as food, often requires extensive sample extraction and preparation prior to instrumental analysis. Sample preparation is often the bottleneck in analysis and there is a need to minimise the number of steps to reduce both time and sources of error. There is also a move towards more environmentally friendly techniques, which use less solvent and smaller sample sizes. Smaller sample size becomes important when dealing with real life problems, such as consumer complaints and alleged chemical contamination. Optimal sample preparation can reduce analysis time, sources of error, enhance sensitivity and enable unequivocal identification, confirmation and quantification. This review considers all aspects of sample preparation, covering general extraction techniques, such as Soxhlet and pressurised liquid extraction, microextraction techniques such as liquid phase microextraction (LPME) and more selective techniques, such as solid phase extraction (SPE), solid phase microextraction (SPME) and stir bar sorptive extraction (SBSE). The applicability of each technique in food analysis, particularly for the determination of trace organic contaminants in foods is discussed.

  13. Current trends in sample preparation for cosmetic analysis.

    PubMed

    Zhong, Zhixiong; Li, Gongke

    2017-01-01

    The widespread applications of cosmetics in modern life make their analysis particularly important from a safety point of view. There is a wide variety of restricted ingredients and prohibited substances that primarily influence the safety of cosmetics. Sample preparation for cosmetic analysis is a crucial step as the complex matrices may seriously interfere with the determination of target analytes. In this review, some new developments (2010-2016) in sample preparation techniques for cosmetic analysis, including liquid-phase microextraction, solid-phase microextraction, matrix solid-phase dispersion, pressurized liquid extraction, cloud point extraction, ultrasound-assisted extraction, and microwave digestion, are presented. Furthermore, the research and progress in sample preparation techniques and their applications in the separation and purification of allowed ingredients and prohibited substances are reviewed. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Preparation and application of a polythiophene solid-phase microextraction fiber for the determination of endocrine-disruptor pesticides in well waters.

    PubMed

    Pelit, Levent; Dizdaş, Tuğberk Nail

    2013-10-01

    A robust solid-phase microextraction fiber was fabricated by electropolymerization of thiophene on a stainless steel wire. This fiber was applied for the determination of endocrine-disruptor pesticides, namely, chlorpyrifos, penconazole, procymidone, bromopropylate, and λ-cyhalothrin in well waters by a headspace solid-phase microextraction procedure. Operational parameters, namely, pH, sample volume, adsorption temperature and time, desorption temperature, stirring rate, and salt amount were optimized as 7.0, 8 mL, 70°C and 20 min, 250°C, 600 rpm, and 0.3 g/mL, respectively. The separation power of GC was coupled with the excellent sensitivity of the developed fiber enabling us to determine pesticide mixtures simultaneously in a ng/mL range. The LOD was in the range of 0.02-0.64 ng/mL. The method was successfully applied for the selective and sensitive determination of target pesticides in well water samples with acceptable recovery values (92-110%). The polythiophene fiber gives satisfactory results compared with commercial fibers. Commonly used pesticides with different polarities were chosen as representative compounds to search the applicability of the fiber for well water analysis collected from vineyards. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Application of a novel cold activated carbon fiber-solid phase microextraction for analysis of organochlorine pesticides in soil.

    PubMed

    Chai, Xiaolan; Jia, Jinping; Sun, Tonghua; Wang, Yalin; Liao, Liyan

    2007-08-01

    A novel and simple analytical procedure using cold activated carbon fiber-solid phase microextraction (CACF-SPME) was applied to determine organochlorine pesticides (OCs) in soil samples. The pesticides in this study consist of alpha -, beta -, gamma -, and delta -hexachlorocyclohexane (HCH). By heating the sample while cooling the fiber, the developed method not only provides better performance in terms of sensitivity, linearity and recovery but also offers shorter adsorption procedure than that of traditional headspace-solid phase microextraction (HS-SPME). The experimental conditions such as the amount of water, adsorption time and adsorption temperature were optimized. Matrix effects were investigated with different types of soils. We concluded that using the standard addition method was required for quantification purposes. The limits of detection obtained using the proposed method range from 0.01 to 0.05 ng/g, and the recoveries for CACF-SPME are in the range of 80.01% to 89.68% with relative standard deviation (RSDs) better than 8.60%. The proposed method was further applied to determine OCs in real agricultural soil. The results are in good agreement with those obtained using traditional ultrasonic extraction. The research demonstrates the suitability of the CACF-SPME for the analysis of OCs in soil.

  16. Improved chip design for integrated solid-phase microextraction in on-line proteomic sample preparation.

    PubMed

    Bergkvist, Jonas; Ekström, Simon; Wallman, Lars; Löfgren, Mikael; Marko-Varga, György; Nilsson, Johan; Laurell, Thomas

    2002-04-01

    A recently introduced silicon microextraction chip (SMEC), used for on-line proteomic sample preparation, has proved to facilitate the process of protein identification by sample clean up and enrichment of peptides. It is demonstrated that a novel grid-SMEC design improves the operating characteristics for solid-phase microextraction, by reducing dispersion effects and thereby improving the sample preparation conditions. The structures investigated in this paper are treated both numerically and experimentally. The numerical approach is based on finite element analysis of the microfluidic flow in the microchip. The analysis is accomplished by use of the computational fluid dynamics-module FLOTRAN in the ANSYS software package. The modeling and analysis of the previously reported weir-SMEC design indicates some severe drawbacks, that can be reduced by changing the microextraction chip geometry to the grid-SMEC design. The overall analytical performance was thereby improved and also verified by experimental work. Matrix-assisted laser desorption/ionization mass spectra of model peptides extracted from both the weir-SMEC and the new grid-SMEC support the numerical analysis results. Further use of numerical modeling and analysis of the SMEC structures is also discussed and suggested in this work.

  17. Novel benzo-15-crown-5 sol-gel coating for solid-phase microextraction.

    PubMed

    Wang, Danhua; Xing, Jun; Peng, Jiagang; Wu, Caiying

    2003-07-11

    A novel dihydroxy-terminated benzo-15-crown-5 was synthesized and applied to prepare a solid-phase microextraction (SPME) fiber coating with sol-gel technology. The optimization of the sol-gel process was studied. The coating method with sol-gel was improved and completed in one run, which economized materials and allowed easier control of the fiber thickness. The repeatability of coating fiber to fiber was better than 4.94% (RSD). The surface of the fiber coating was well-distributed and an electron microscopy experiment suggested a porous structure for crown ether coating, providing high surface areas and allowing for high extraction efficiency. The coating has a high thermal stability (350 degrees C), long lifetime and can stand solvent (organic and inorganic) rinsing due to the chemical binding between the coating and the fiber surface. Non-polar benzene, toluene, ethylbenzene, xylenes, chlorobenzenes, polar phenolic compounds and arylamines were used to evaluate the character of the fiber coating by headspace SPME-gas chromatography technology. For phenols, the linear concentrations ranged from 5 to 1000 microg/l, the detection limits were between 0.05 and 1 microg/l, and the RSD was less than 5%. The addition of benzo-crown ether not only increases the thermal stability of the fiber coating, but also enhances the selectivity of the fiber coating. Compared with commercially available SPME fibers poly(dimethylsiloxane) and polyacrylate, the few phases showed better selectivity and sensitivity towards non-polar and polar aromatic compounds.

  18. Serum levels of organochlorine pesticides in the general population of Thessaly, Greece, determined by HS-SPME GC-MS method.

    PubMed

    Koureas, Michalis; Karagkouni, Foteini; Rakitskii, Valerii; Hadjichristodoulou, Christos; Tsatsakis, Aristidis; Tsakalof, Andreas

    2016-07-01

    In this study, exposure levels of organochlorine pesticides (OCs) were determined in general population residing in Larissa, central Greece. Serum samples from 103 volunteers were analyzed by optimized headspace solid-phase microextraction gas chromatography-mass spectrometry, to detect and quantify OC levels. The most frequently detected analytes were p,p'-DDE (frequency 99%, median:1.25ng/ml) and Hexachlorobenzene (HCB) (frequency 69%, median: 0.13ng/ml). Statistical analysis revealed a significant relationship of p,p'-DDE and HCB levels with age. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Gamma ray degradation of electrolytes containing alkylcarbonate solvents and a lithium salt

    NASA Astrophysics Data System (ADS)

    Caillon-Caravanier, Magaly; Jones, Jennifer; Anouti, Mérièm; Montigny, Frédéric; Willmann, Patrick; David, Jean-Pierre; Soonckindt, Sabine; Lemordant, Daniel

    Lithium-ion batteries for space applications, such as satellites, are subjected to cosmic radiations, in particular, γ-irradiation. In this study, the effects of this radiation on electrolytes and their components used in the lithium-ion batteries are investigated. The conductivity and viscosity of the samples have been measured before and after the irradiation. The modifications are evaluated by spectral analyses such as Fourier transform infrared spectroscopy (FTIR), nuclear magnetic resonance spectroscopy (1H and 13C NMR), solid phase microextraction-gas chromatography (SPME-GC) and gas chromatography-mass spectroscopy (GC-MS). The experimental results show that only the samples containing vinylene carbonate and/or the lithium salt LiPF 6 are degraded by γ-radiation.

  20. Applicability of the new 60 μm polyethylene glycol solid-phase microextraction fiber assembly for the simultaneous analysis of six pesticides in water.

    PubMed

    Pereira, Ana; Silva, Emília; Cerejeira, Maria J

    2014-01-01

    A solid-phase microextraction (SPME) method has been applied for the simultaneous analysis of six pesticides in water, with polar to moderately polar range, by gas chromatography-mass spectrometry (GC-MS). Two types of fiber coatings [60 µm polyethylene glycol (PEG) and 65 µm polydimethylsiloxane/divinylbenzene (PDMS/DVB)] and the effect of salt (addition of 10 and 25% of NaCl) were compared. The extraction efficiency was higher with PEG than with the PDMS/DVB fiber for all pesticides, with the exception of terbuthylazine and phosmet, and with addition of 25% NaCl. The optimized SPME-GC-MS method, adopting the PEG fiber and the addition of 25% NaCl, in addition to other conditions [60 min of direct dipping of the fiber into the water sample (10 mL) under agitation (250 rpm) at ambient temperature; desorption period of 5 min at 240°C] allowed the determination of all studied pesticides and showed good linearity for concentrations ranging from 0.05 to 5 µg/L. Limits of detection varied between 0.003 and 0.145 µg/L, with values below 0.025 µg/L for most of the analytes. Precision ranged from 4.2 to 12%. The proposed method is fast and simple, and was proven to be reliable for the routine analysis of pesticides in water, primarily for environmental monitoring.

  1. Optimisation of a simple and reliable method based on headspace solid-phase microextraction for the determination of volatile phenols in beer.

    PubMed

    Pizarro, C; Pérez-del-Notario, N; González-Sáiz, J M

    2010-09-24

    A simple, accurate and sensitive method based on headspace solid-phase microextraction (HS-SPME) coupled to gas chromatography-tandem mass spectrometry (GC-MS/MS) was developed for the analysis of 4-ethylguaiacol, 4-ethylphenol, 4-vinylguaiacol and 4-vinylphenol in beer. The effect of the presence of CO2 in the sample on the extraction of analytes was examined. The influence on extraction efficiency of different fibre coatings, of salt addition and stirring was also evaluated. Divinylbenzene/carboxen/polydimethylsiloxane was selected as extraction fibre and was used to evaluate the influence of exposure time, extraction temperature and sample volume/total volume ratio (Vs/Vt) by means of a central composite design (CCD). The optimal conditions identified were 80 degrees C for extraction temperature, 55 min for extraction time and 6 mL of beer (Vs/Vt 0.30). Under optimal conditions, the proposed method showed satisfactory linearity (correlation coefficients between 0.993 and 0.999), precision (between 6.3% and 9.7%) and detection limits (lower than those previously reported for volatile phenols in beers). The method was applied successfully to the analysis of beer samples. To our knowledge, this is the first time that a HS-SPME based method has been developed to determine simultaneously these four volatile phenols in beers. Copyright 2010 Elsevier B.V. All rights reserved.

  2. In Situ Synthesis of Porous Carbons by Using Room-Temperature, Atmospheric-Pressure Dielectric Barrier Discharge Plasma as High-Performance Adsorbents for Solid-Phase Microextraction.

    PubMed

    Lin, Yao; Wu, Li; Xu, Kailai; Tian, Yunfei; Hou, Xiandeng; Zheng, Chengbin

    2015-09-21

    A one-step, template-free method is described to synthesize porous carbons (PCs) in situ on a metal surface by using a room-temperature, atmospheric-pressure dielectric barrier discharge (DBD) plasma. This method not only features high efficiency, environmentally friendliness, and low cost and simple equipment, but also can conveniently realize large-area synthesis of PCs by only changing the design of the DBD reactor. The synthesized PCs have a regulated nestlike morphology, and thus, provide a high specific surface area and high pore volume, which result in excellent adsorption properties. Its applicability was demonstrated by using a PC-coated stainless-steel fiber as a solid-phase microextraction (SPME) fiber to preconcentrate polycyclic aromatic hydrocarbons (PAHs) prior to analysis by gas chromatography with flame ionization detection (GC-FID). The results showed that the fiber exhibited excellent enrichment factors (4.1×10(4) to 3.1×10(5)) toward all tested PAHs. Thus, the PC-based SPME-GC-FID provides low limits of detection (2 to 20 ng L(-1)), good precision (<7.8%), and good recoveries (80-115%) for ultra-sensitive determination of PAHs in real water samples. In addition, the PC-coated fiber could be stable enough for more than 500 replicate extraction cycles. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Mesoporous carbon-zirconium oxide nanocomposite derived from carbonized metal organic framework: A coating for solid-phase microextraction.

    PubMed

    Saraji, Mohammad; Mehrafza, Narges

    2016-08-19

    In this paper, a mesoporous carbon-ZrO2 nanocomposite was fabricated on a stainless steel wire for the first time and used as the solid-phase microextraction coating. The fiber was synthesized with the direct carbonization of a Zr-based metal organic framework. With the utilization of the metal organic framework as the precursor, no additional carbon source was used for the synthesis of the mesoporous carbon-ZrO2 nanocomposite coating. The fiber was applied for the determination of BTEX compounds (benzene, toluene, ethylbenzene and m, p-xylenes) in different water samples prior to gas chromatography-flame ionization detection. Such important experimental factors as synthesis time and temperature, salt concentration, equilibrium and extraction time, extraction temperature, desorption time and desorption temperature were studied and optimized. Good linearity in the concentration range of 0.2-200μgL(-1) and detection limits in the range of 0.05-0.56μgL(-1) was achieved for BTEX compounds. The intra- and inter-day relative standard deviations were in the range of 3.5-4.8% and 4.9-6.7%, respectively. The prepared fiber showed high capability for the analysis of BTEX compounds in different water and wastewater samples with good relative recoveries in the range of 93-107%. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Solid-phase microextraction coupled to liquid chromatography for the analysis of phenolic compounds in water.

    PubMed

    González-Toledo, E; Prat, M D; Alpendurada, M F

    2001-07-20

    Solid-phase microextraction (SPME) coupled to high-performance liquid chromatography (HPLC) has been applied to the analysis of priority pollutant phenolic compounds in water samples. Two types of polar fibers [50 microm Carbowax-templated resin (CW-TPR) and 60 microm polydimethylsiloxane-divinylbenzene (PDMS-DVB)] were evaluated. The effects of equilibration time and ionic strength of samples on the adsorption step were studied. The parameters affecting the desorption process, such as desorption mode, solvent composition and desorption time, were optimized. The developed method was used to determine the phenols in spiked river water samples collected in the Douro River, Portugal. Detection limits of 1-10 microg l(-1) were achieved under the optimized conditions.

  5. Application of solid-phase microextraction method to determine bioavailable fraction of PAH in hazardous waste.

    PubMed

    Jefimova, J; Irha, N; Mägi, R; Kirso, U

    2012-10-01

    The solid-phase microextraction (SPME) method was developed to determine PAH free dissolved concentration (C(free)) in field leachates from hazardous waste disposal. SPME technique, involving a 100-μm polydimethylsiloxane (PDMS) fiber coupled to GC-MS was optimized for determination of C(free). The following PAH were found in bioavailable form: acenaphthylene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, with C(free) varying between 2.38 and 62.35 ng/L. Conventional solvent extraction was used for measurement of total concentration (C(total)) in the same samples, and ranging from 1.26 to 77.56 μg/L. Determining C(free) of the hydrophobic toxic pollutants could give useful information for risk assessment of the hazardous waste.

  6. Development of an analytical method coupling cell membrane chromatography with gas chromatography-mass spectrometry via microextraction by packed sorbent and its application in the screening of volatile active compounds in natural products.

    PubMed

    Li, Miao; Wang, Sicen; He, Langchong

    2015-01-01

    Natural products (NPs) are important sources of lead compounds in modern drug discovery. To facilitate the screening of volatile active compounds in NPs, we have developed a new biochromatography method that uses rat vascular smooth muscle cells (VSMC), which are rich in L-type calcium channels (LCC), to prepare the stationary phase. This integrated method, which couples cell membrane chromatography (CMC) with gas chromatography-mass spectrometry (GC-MS) via microextraction by packed sorbent (MEPS) technology, has been termed VSMC/CMC-MEPS-GC-MS. Methodological validation confirmed its specificity, reliability and convenience. Screening results for Radix Angelicae Dahuricae and Fructus Cnidii obtained using VSMC/CMC-MEPS-GC-MS were consistent with those obtained using VSMC/CMC-offline-GC-MS. MEPS connection plays as simplified solid-phase extraction and replaces the uncontrollable evaporation operation in reported offline connections, so our new method is supposed to be more efficient and reliable than the offline ones, especially for compounds that are volatile, thermally unstable or difficult to purify. In application, senkyunolide A and ligustilide were preliminary identified as the volatile active components in Rhizoma Chuanxiong. We have thus confirmed the suitability of VSMC/CMC-MEPS-GC-MS for volatile active compounds screening in NP. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Combined dispersive solid-phase extraction-dispersive liquid-liquid microextraction-derivatization for gas chromatography-mass spectrometric determination of aliphatic amines on atmospheric fine particles.

    PubMed

    Majedi, Seyed Mohammad; Lee, Hian Kee

    2017-02-24

    Short-chain aliphatic amines are ubiquitous in the atmospheric environment. They play an important role in the formation and growth of atmospheric particles. As such, there is a pressing need to monitor these particle-bound compounds present at trace quantities. The present work describes an efficient, one-step microextraction technique for the preconcentration and detection of trace levels of 10 aliphatic amines on fine particles (particulate matter of 2.5μm or less (PM 2.5 )) in the atmosphere. After extraction of amines from particles in acidified water samples, carbon-based sorbents (in dispersive solid-phase extraction mode), and vortex agitation were utilized for simultaneous derivatization-extraction and dispersive liquid-liquid microextraction. The approach significantly increased the recoveries and enrichment of the amine derivatives. This one-step, combined technique is proposed for the first time. Several influential factors including type and concentration of derivatization reagent (for gas chromatographic separation), type of buffer, sample pH, types and volumes of extraction and disperser solvents, type and amount of sorbent, vortex time and temperature, desorption solvent type and volume, and salt content were investigated and optimized. Under the optimum conditions, high enrichment factors (in the range of between 307 and 382) and good reproducibility (relative standard deviations, below 7.0%, n=5) were achieved. The linearity ranged from 0.1μg/L-100μg/L, and from 0.5μg/L-100μg/L, depending on the analytes. The limits of detection were between 0.02μg/L (corresponding to ∼0.01ng/m 3 in air) and 0.09μg/L (corresponding to ∼0.04ng/m 3 in air). The developed method was successfully applied to the analysis of PM 2.5 samples collected by air sampling through polytetrafluoroethylene filters. The concentration levels of amines ranged from 1.04 to 4.16ng/m 3 in the air sampled. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Dispersive liquid-liquid microextraction and gas chromatography accurate mass spectrometry for extraction and non-targeted profiling of volatile and semi-volatile compounds in grape marc distillates.

    PubMed

    Fontana, Ariel; Rodríguez, Isaac; Cela, Rafael

    2018-04-20

    The suitability of dispersive liquid-liquid microextraction (DLLME) and gas chromatography accurate mass spectrometry (GC-MS), based on a time-of-flight (TOF) MS analyzer and using electron ionization (EI), for the characterization of volatile and semi-volatile profiles of grape marc distillates (grappa) are evaluated. DLLME conditions are optimized with a selection of compounds, from different chemical families, present in the distillate spirit. Under final working conditions, 2.5 mL of sample and 0.5 mL of organic solvents are consumed in the sample preparation process. The absolute extraction efficiencies ranged from 30 to 100%, depending on the compound. For the same sample volume, DLLME provided higher responses than solid-phase microextraction (SPME) for most of the model compounds. The GC-EI-TOF-MS records of grappa samples were processed using a data mining non-targeted search algorithm. In this way, chromatographic peaks and accurate EI-MS spectra of sample components were linked. The identities of more than 140 of these components are proposed from comparison of their accurate spectra with those in a low resolution EI-MS database, accurate masses of most intense fragment ions of known structure, and available chromatographic retention index. The use of chromatographic and spectral data, associated to the set of components mined from different grappa samples, for multivariate analysis purposes is also illustrated in the study. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Determination of N,N-dimethyltryptamine in beverages consumed in religious practices by headspace solid-phase microextraction followed by gas chromatography ion trap mass spectrometry.

    PubMed

    Gaujac, Alain; Dempster, Nicola; Navickiene, Sandro; Brandt, Simon D; de Andrade, Jailson Bittencourt

    2013-03-15

    A novel analytical approach combining solid-phase microextraction (SPME)/gas chromatography ion trap mass spectrometry (GC-IT-MS) was developed for the detection and quantification N,N-dimethyltryptamine (DMT), a powerful psychoactive indole alkaloid present in a variety of South American indigenous beverages, such as ayahuasca and vinho da jurema. These particular plant products, often used within a religious context, are increasingly consumed throughout the world following an expansion of religious groups and the availability of plant material over the Internet and high street shops. The method described in the present study included the use of SPME in headspace mode combined GC-IT-MS and included the optimization of the SPME procedure using multivariate techniques. The method was performed with a polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber in headspace mode (70 min at 60 °C) which resulted in good precision (RSD<8.6%) and accuracy values (71-109%). Detection and quantification limits obtained for DMT were 0.78 and 9.5 mg L(-1), respectively and good linearity (1.56-300 mg L(-1), r(2)=0.9975) was also observed. In addition, the proposed method showed good robustness and allowed for the minimization of sample manipulation. Five jurema beverage samples were prepared in the laboratory in order to study the impact of temperature, pH and ethanol on the ability to extract DMT into solution. The developed method was then applied to the analysis of twelve real ayahuasca and vinho da jurema samples, obtained from Brazilian religious groups, which revealed DMT concentration levels between 0.10 and 1.81 g L(-1). Copyright © 2013 Elsevier B.V. All rights reserved.

  10. High-throughput analysis of bergamot essential oil by fast solid-phase microextraction-capillary gas chromatography-flame ionization detection.

    PubMed

    Tranchida, Peter Quinto; Presti, Maria Lo; Costa, Rosaria; Dugo, Paola; Dugo, Giovanni; Mondello, Luigi

    2006-01-20

    The advantages of using a narrow-bore column in headspace solid-phase microextraction-gas chromatographic (HS-SPME-GC) analysis are investigated. An automated rapid HS-SPME-GC method for the determination of volatile compounds in a complex sample (bergamot essential oil) was developed. A low-capacity (7 microm) SPME fibre was employed, enabling a short equilibration time (15 min). The absorbed volatile compounds were then separated in 12.5 min on a 10 m x 0.1 mm I.D. capillary. The fast GC method was characterized by relatively moderate GC parameters (head pressure: 173 kPa; temperature program rate: 12 degrees C/min). The employment of the low-capacity fibre also suited the reduced sample capacity of the capillary employed, hence column overloading was avoided. Analytical repeatibility was determined in terms of retention times (maximum RSD: 0.32%) and peak areas (maximum RSD: 9.80%). The results obtained were compared to those derived from a conventional HS-SPME-GC (a 30 microm SPME fibre and 0.25 mm I.D. capillary were used) application on the same sample. In this respect, a great reduction of analytical time was obtained both with regard to the conventional SPME equilibration and GC run times, which both required 50 min. Peak resolution was altogether comparable in both applications. Although a slight loss in terms of sensitivity was observed in the rapid approach (generally within the 25-50% range), this did not impair the detection of all peaks of interest. Finally, the selectivities of the 30 and 7 microm fibres were evaluated and, as expected, these were in good agreement.

  11. Measurement of non-enteric emission fluxes of volatile fatty acids from a California dairy by solid phase micro-extraction with gas chromatography/mass spectrometry

    NASA Astrophysics Data System (ADS)

    Alanis, Phillip; Sorenson, Mark; Beene, Matt; Krauter, Charles; Shamp, Brian; Hasson, Alam S.

    Dairies are a major source of volatile organic compounds (VOCs) in California's San Joaquin Valley; a region that experiences high ozone levels during summer. Short-chain carboxylic acids, or volatile fatty acids (VFAs), are believed to make up a large fraction of VOC emissions from these facilities, although there are few studies to substantiate this. In this work, a method using a flux chamber coupled to solid phase micro-extraction (SPME) fibers followed by analysis using gas chromatography/mass spectrometry was developed to quantify emissions of six VFAs (acetic acid, propanoic acid, butanoic acid, pentanoic acid, hexanoic acid and 3-methyl butanoic acid) from non-enteric sources. The technique was then used to quantify VFA fluxes from a small dairy located on the campus of California State University Fresno. Both animal feed and animal waste are found to be major sources of VFAs, with acetic acid contributing 70-90% of emissions from the sources tested. Measured total acid fluxes during spring (with an average temperature of 20 °C) were 1.84 ± 0.01, 1.06 ± 0.08, (1.3 ± 0.5) × 10 -2, (1.7 ± 0.2) × 10 -2 and (1.2 ± 0.5) × 10 -2 g m -2 h -1 from silage, total mixed rations, flushing lane, open lot and lagoon sources, respectively. VFA emissions from the sources tested total 390 ± 80 g h -1. The data indicate high fluxes of VFAs from dairy facilities, but differences in the design and operation of dairies in the San Joaquin Valley as well as seasonal variations mean that additional measurements must be made to accurately determine emissions inventories for the region.

  12. Quantification of selected volatile organic compounds in human urine by gas chromatography selective reagent ionization time of flight mass spectrometry (GC-SRI-TOF-MS) coupled with head-space solid-phase microextraction (HS-SPME).

    PubMed

    Mochalski, Paweł; Unterkofler, Karl

    2016-08-07

    Selective reagent ionization time of flight mass spectrometry with NO(+) as the reagent ion (SRI-TOF-MS(NO(+))) in conjunction with gas chromatography (GC) and head-space solid-phase microextraction (HS-SPME) was used to determine selected volatile organic compounds in human urine. A total of 16 volatiles exhibiting high incidence rates were quantified in the urine of 19 healthy volunteers. Amongst them there were ten ketones (acetone, 2-butanone, 3-methyl-2-butanone, 2-pentanone, 3-methyl-2-pentanone, 4-methyl-2-pentanone, 2-hexanone, 3-hexanone, 2-heptanone, and 4-heptanone), three volatile sulphur compounds (dimethyl sulfide, allyl methyl sulfide, and methyl propyl sulfide), and three heterocyclic compounds (furan, 2-methylfuran, 3-methylfuran). The concentrations of the species under study varied between 0.55 nmol L(-1) (0.05 nmol mmol(-1)creatinine) for allyl methyl sulfide and 11.6 μmol L(-1) (1.54 μmol mmol(-1)creatinine) for acetone considering medians. Limits of detection (LODs) ranged from 0.08 nmol L(-1) for allyl methyl sulfide to 1.0 nmol L(-1) for acetone and furan (with RSDs ranging from 5 to 9%). The presented experimental setup assists both real-time and GC analyses of volatile organic compounds, which can be performed consecutively using the same analytical system. Such an approach supports the novel concept of hybrid volatolomics, an approach which combines VOC profiles obtained from two or more body fluids to improve and complement the chemical information on the physiological status of an individual.

  13. Rapid screening procedure based on headspace solid-phase microextraction and gas chromatography-mass spectrometry for the detection of many recreational drugs in hair.

    PubMed

    Gentili, Stefano; Cornetta, Maria; Macchia, Teodora

    2004-03-05

    An increasing number of synthetic drugs are appearing on the illicit market and on the scene of drug use by youngsters. Official figures are underestimated. In addition, immunochemical tests are blind to many of these drugs and appropriate analytical procedures for routine clinical and epidemiological purposes are lacking. Therefore, the perceived increasing abuse of recreational drugs has not been proved yet. In a previous paper, we proposed a procedure for the preliminary screening of several recreational substances in hair and other biological matrices. Unfortunately, this procedure cannot apply to cocaine. Consequently, we performed a new headspace solid-phase microextraction and gas chromatography-mass spectrometry (HS-SPME-GC-MS) procedure for the simultaneous detection of cocaine, amphetamine (A), methamphetamine (MA), methylen-dioxyamphetamine (MDA), methylen-dioxymethamphetamine (MDMA), methylen-dioxyethamphetamine (MDE), N-methyl-1-(1,3-benzodioxol-5-yl)-2-butanamine (MBDB), ketamine, and methadone in human hair. Hair was washed with water and acetone in an ultrasonic bath. A short acid extraction with 1M hydrochloric acid was needed; the fiber was exposed to a 5 min absorption at 90 degrees C and thermal desorption was performed at 250 degrees C for 3 min. The procedure was simple, rapid, required small quantities of sample and no derivatization. Good linearity was obtained over the 0.1-20.0 ng/mg range for the target compounds. Sensitivity was good enough: limits of detection (LOD) were 0.7 ng/mg of hair for the majority of substances. The intra-day precision ranged between 7 and 20%. This paper deals with the analytical performance of this procedure and its preliminary application to hair samples obtained on a voluntary basis from 183 young people (138 males and 45 females) in the Rome area.

  14. An improved method for the analysis of 2-aminoacetophenone in wine based on headspace solid-phase microextraction and heart-cut multidimensional gas chromatography with selective detection by tandem mass spectrometry.

    PubMed

    Schmarr, Hans-Georg; Keiser, Jutta; Krautwald, Susann

    2016-12-16

    Heart-cut multidimensional gas chromatography coupled to selective mass spectrometric detection (H/C MDGC-MS-MS) was shown to be a suitable combination for analysis of the key component for the wine off-flavor named "atypical aging off-flavor" (german: "Untypische Alterungsnote", UTA), 2-aminoacetophenone (2-AAP). Headspace solid phase microextraction (HS-SPME) was applied as an easy to automate sample preparation step suiting routine control situations. During method development two critical aspects were found, of which one is the chemical degradation of the neat substance, leading to signal reduction and a false response behavior. A second aspect is the pH stability of the deuterated isotopologue 1-(2-aminophenyl)-2,2,2-trideuterio-ethanone (2-AAP-d3) used for quantification via a stable isotope dilution assay. Despite an earlier suggestion to increase the extractable amount of 2-AAP and its isotopic standard in the headspace, alkalization of 2-AAP-d3 containing aqueous samples were found to be critical. In such a milieu a deuterium exchange can then cause erroneous quantitative results. The method proposed in our study thus uses native wine pH conditions and proved to be suitable for routine control with respect to the detection of the "atypical aging off-flavor" in wine at concentration levels below its sensory threshold of about 1μgL -1 . Good linearity was obtained in the calibrated range from 0.1-8μgL -1 (y=1,2338x+0,1029, R=0,9985) with limits of detection or quantification being 0.01 and 0.14μg/L, respectively. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Determination of phthalate esters in drinking water and edible vegetable oil samples by headspace solid phase microextraction using graphene/polyvinylchloride nanocomposite coated fiber coupled to gas chromatography-flame ionization detector.

    PubMed

    Amanzadeh, Hatam; Yamini, Yadollah; Moradi, Morteza; Asl, Yousef Abdossalmi

    2016-09-23

    In the current study, a graphene/polyvinylchloride nanocomposite was successfully coated on a stainless steel substrate by a simple dip coating process and used as a novel headspace solid phase microextraction (HS-SPME) fiber for the extraction of phthalate esters (PEs) from drinking water and edible vegetable oil samples. The prepared SPME fibers exhibited high extractability for PEs (due to the dominant role of π-π stacking interactions and hydrophobic effects) yielding good sensitivity and precision when followed by a gas chromatograph with a flame ionization detector (GC-FID). The optimization strategy of the extraction process was carried out using the response surface method based on a central composite design. The developed method gave a low limit of detection (0.06-0.08μgL(-1)) and good linearity (0.2-100μgL(-1)) for the determination of the PEs under the optimized conditions (extraction temperature, 70±1°C; extraction time, 35min; salt concentration, 30% w/v; stirring rate, 900rpm; desorption temperature, 230°C; and desorption time, 4min) whereas the repeatability and fiber-to-fiber reproducibility were in the range 6.1-7.8% and 8.9-10.2%, respectively. Finally, the proposed method was successfully applied to the analysis of PEs in drinking water and edible oil samples with good recoveries (87-112%) and satisfactory precisions (RSDs<8.3%), indicating the absence of matrix effects in the proposed HS-SPME method. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Direct determination of acrylamide in potato chips by using headspace solid-phase microextraction coupled with gas chromatography-flame ionization detection.

    PubMed

    Ghiasvand, Ali Reza; Hajipour, Somayeh

    2016-01-01

    Acrylamide is a potentially toxic and carcinogenic substance present in many high-consumption foods. Recently, this matter has been placed in category of "reasonably anticipated to be a human carcinogen" by National Toxicology Program (NTP). Therefore, simple and cost-effective determination of acrylamide in food samples has attracted intense interest. The most reported techniques for this purpose are GC-MS and LC-MS, which are very expensive and available in few laboratories. In this research, for the first time, a rapid, easy and low-cost method is introduced for sensitive and precise determination of acrylamide in foodstuffs, using gas chromatography-flame ionization detection (GC-FID) system after its direct trapping in the upper atmosphere of samples by headspace solid-phase microextraction (HS-SPME). The effects of main experimental variables were studied and the optimized parameters were obtained as the type of fiber, carboxen/divinylbenzene/polydimethylsiloxane (CAR/DVB/PDMS); extraction time, 30 min; extraction temperature, 60°C; moisture content, 10 µL water per 1g of sample; desorption time, 2 min; and desorption temperature, 230°C. The linear calibration graph was obtained in the range of 0.77-50 µg g(-1), with regression coefficient of 0.998. The detection and quantification limits of the proposed method were 0.22 and 0.77 µg g(-1), respectively. The recoveries, for different food samples, were 79.6-95.7%. The repeatability of measurements, expressed as relative standard deviation (RSD), were found to be 4.1-8.0% (n=9). The proposed HS-SPME-GC-FID method was successfully carried out for quantifying of trace levels of acrylamide in some processed food products (chips and French fries), sold in open local markets. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Optimisation of solid-phase microextraction combined with gas chromatography-mass spectrometry based methodology to establish the global volatile signature in pulp and skin of Vitis vinifera L. grape varieties.

    PubMed

    Perestrelo, Rosa; Barros, António S; Rocha, Sílvia M; Câmara, José S

    2011-09-15

    The volatiles (VOCs) and semi-volatile organic compounds (SVOCs) responsible for aroma are mainly present in skin of grape varieties. Thus, the present investigation is directed towards the optimisation of a solvent free methodology based on headspace-solid-phase microextraction (HS-SPME) combined with gas chromatography-quadrupole mass spectrometry (GC-qMS) in order to establish the global volatile composition in pulp and skin of Bual and Bastardo Vitis vinifera L. varieties. A deep study on the extraction-influencing parameters was performed, and the best results, expressed as GC peak area, number of identified compounds and reproducibility, were obtained using 4 g of sample homogenised in 5 mL of ultra-pure Milli-Q water in a 20 mL glass vial with addition of 2g of sodium chloride (NaCl). A divinylbenzene/carboxen/polydimethylsiloxane fibre was selected for extraction at 60°C for 45 min under continuous stirring at 800 rpm. More than 100 VOCs and SVOCs, including 27 monoterpenoids, 27 sesquiterpenoids, 21 carbonyl compounds, 17 alcohols (from which 2 aromatics), 10 C(13) norisoprenoids and 5 acids were identified. The results showed that, for both grape varieties, the levels and number of volatiles in skin were considerably higher than those observed in pulp. According to the data obtained by principal component analysis (PCA), the establishment of the global volatile signature of grape and the relationship between different part of grapes-pulp and skin, may be an useful tool to winemaker decision to define the vinification procedures that improves the organoleptic characteristics of the corresponding wines and consequently contributed to an economic valorization and consumer acceptance. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Headspace solid-phase microextraction coupled to gas chromatography-tandem mass spectrometry for the determination of haloanisoles in sparkling (cava and cider) and non-sparkling (wine) alcoholic beverages.

    PubMed

    Ruiz-Delgado, Ana; Arrebola-Liébanas, Francisco Javier; Romero-González, Roberto; López-Ruiz, Rosalía; Garrido Frenich, Antonia

    2016-10-01

    A highly sensitive analytical method was developed to determine 2,4,6-trichloroanisole (TCA), 2,3,4,6-tetrachloroanisole (TeCA), 2,4,6-tribromoanisole (TBA) and 2,3,4,5,6-pentachloroanisole (PCA) in sparkling alcoholic beverages. The method was based on the use of headspace solid-phase microextraction (HS-SPME) using a polydimethylsiloxane (PDMS) fibre. It was coupled to gas chromatography-triple quadrupole tandem mass spectrometry (GC-QqQ-MS/MS) for the detection and quantification of the target haloanisoles. The method was fully automated and no sample preparation was needed. The method was validated for alcoholic beverages. The influence of CO 2 on the extraction efficiency was also evaluated for the studied sparkling drinks (cava and cider). All the calibration curves showed good linearity (R 2  > 0.98) within the tested range (1-50 ng l -1 ). Recoveries were evaluated at three different levels (1, 5 and 50 ng l -1 ) and were always between 71% and 119%. Precision was expressed as relative standard deviation (RSD), and was evaluated as intra- and inter-day precisions, with values ≤ 22% in both cases. Limits of quantitation (LOQs) were ≤ 0.91 ng l -1 , which are below the sensory threshold levels for such compounds in humans. The validated method was applied to commercial samples, 10 cavas and 10 ciders, but it was also used for the analysis of nine red wines and four white wines, demonstrating the further applicability of the proposed method to non-sparkling beverages. TCA was detected in most samples at up to 0.45 ng l -1 .

  19. Simultaneous analysis of organochlorine pesticides and polychlorinated biphenyls in air samples by using accelerated solvent extraction (ASE) and solid-phase micro-extraction (SPME) coupled to gas chromatography dual electron capture detection.

    PubMed

    Mokbel, Haifaa; Al Dine, Enaam Jamal; Elmoll, Ahmad; Liaud, Céline; Millet, Maurice

    2016-04-01

    An analytical method associating accelerated solvent extraction (ASE) and solid-phase micro-extraction (SPME) in immersion mode combined with gas chromatography dual electrons capture detectors (SPME-GC-2ECD) has been developed and studied for the simultaneous determination of 19 organochlorine pesticides (OCPs) and 22 polychlorinated biphenyls (PCBs) in air samples (active and XAD-2 passive samplers). Samples were extracted with ASE with acetonitrile using the following conditions: temperature, 150 °C; pressure, 1500 psi; static, 15 min; cycles, 3; purge, 300 s; flush, 100 %. Extracts were reduced to 1 mL, and 500 μL of this extract, filled with deionised water, was subject to SPME extraction. Experimental results indicated that the proposed method attained the best extraction efficiency under the optimised conditions: extraction of PCB-OCP mixture using 100-μm PDMS fibre at 80 °C for 40 min with no addition of salt. The performance of the proposed ASE-SPME-GC-2ECD methodology with respect to linearity, limit of quantification and detection was evaluated by spiking of XAD-2 resin with target compounds. The regression coefficient (R (2)) of most compounds was found to be high of 0.99. limits of detection (LODs) are between 0.02 and 4.90 ng m(-3), and limits of quantification (LOQs) are between 0.05 and 9.12 ng m(-3) and between 0.2 and 49 ng/sampler and 0.52 and 91 ng/sampler, respectively, for XAD-2 passive samplers. Finally, a developed procedure was applied to determine selected PCBs and OCPs in the atmosphere.

  20. [Rapid determination of volatile flavor compounds in soy sauce using head space solid-phase microextraction and gas chromatography-mass spectrometry].

    PubMed

    Yan, Liujun; Zhang, Yanfang; Tao, Wenyi; Wang, Liping; Wu, Shengfang

    2008-05-01

    A rapid and simple method was developed for the determination of volatile flavor compounds (VFCs) in soy sauce by head space solid-phase microextraction (HS-SPME) coupled to capillary gas chromatography-mass spectrometry (GC-MS). Five types of SPME fibers, including 85 microm PA, 100 microm PDMS, 75 microm CAR/PDMS, 65 microm PDMS/DVB, 50 microm DVB/CAR/PDMS were investigated. Three parameters for HS-SPME in terms of adsorption time, salt concentration, and extraction temperature were optimized. Adsorption time tested in this study were 20, 40 and 60 minutes; the salt concentrations were 180, 210, 250, 270 and 300 g/L; and extraction temperatures were 25, 35, 45, 55 and 65 degrees C. The concentrations of the compounds were calculated based on their relative peak areas to the internal standard of 2-octanol. An 85 microm PA fiber, adsorption time of 40 min, a temperature of 45 degrees C and NaCl concentration of 250 g/L were selected as th optimum conditions. This optimized method was applied to evaluate a real sample. As a result, 97 compounds in a soy sauce sample were isolated and identified successfully. The results showed that alcohols, carboxylic acids, esters and phenols were the major VFCs of soy sauce. The most important groups of volatile compounds in the soy sauce sample were ethanol, hexadecanoic acid, phenylethyl alcohol and 2,3-butanediol. In addition, some oxo-compounds and heterocyclic compounds were also found. The average relative standard deviation of the relative peak area was 12.1%, and the recoveries were 79.9% - 109.6%. The method is simple, fast and accurate with high reproducibility, high sensitivity and low cost.

  1. Simultaneous determination of perfluoroalkyl iodides, perfluoroalkane sulfonamides, fluorotelomer alcohols, fluorotelomer iodides and fluorotelomer acrylates and methacrylates in water and sediments using solid-phase microextraction-gas chromatography/mass spectrometry.

    PubMed

    Bach, Cristina; Boiteux, Virginie; Hemard, Jessica; Colin, Adeline; Rosin, Christophe; Munoz, Jean-François; Dauchy, Xavier

    2016-05-27

    Here, we developed and validated a headspace-solid-phase microextraction-gas chromatography/mass spectrometry (HS-SPME-GC/MS) method for the determination of 14 volatile perfluorinated alkylated substances (PFASs) in water and sediment samples according to SANTE 11945/2015 guidelines. Three fluorotelomer alcohols (FTOHs), two perfluoroalkyl iodides (PFIs), three fluorotelomer iodides (FTIs), four fluorotelomer acrylates and methacrylates (FTACs and FTMACs) and two perfluoroalkyl sulfonamides (FASAs) were analysed simultaneously to assess the occurrence of these compounds from their emission sources to the outlets in water treatment plants. Several SPME parameters were optimised for both water and sediment to maximise responses and keep analysis time to a minimum. In tap water, the limits of quantification (LOQs) were found to be between 20ng/L and 100ng/L depending on the analyte, with mean recoveries ranging from 76 to 126%. For sediments, LOQs ranged from 1 to 3ng/g dry weight depending on the target compound, with mean recoveries ranging from 74 to 125%. SPME considerably reduced sample preparation time and its use provided a sensitive, fast and simple technique. We then used this HS-SPME-GC/MS method to investigate the presence of volatile PFASs in the vicinity of an industrial facility. Only 8:2 FTOH and 10:2 FTOH were detected in a few water and sediment samples at sub-ppb concentration levels. Moreover, several non-target fluorotelomers (12:2 FTOH, 14:2 FTOH and 10:2 FTI) were identified in raw effluent samples. These long-chain fluorotelomers have high bioaccumulative potential in the aquatic environment compared with short-chain fluorotelomers such as 6:2 FTOH and 6:2 FTI. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Fabrication of a novel nanocomposite based on sol-gel process for hollow fiber-solid phase microextraction of aflatoxins: B1 and B2, in cereals combined with high performane liquid chromatography-diode array detection.

    PubMed

    Es'haghi, Zarrin; Sorayaei, Hoda; Samadi, Fateme; Masrournia, Mahboubeh; Bakherad, Zohreh

    2011-10-15

    The new pre-concentration technique, hollow fiber-solid phase microextraction based on carbon nanotube reinforced sol-gel and liquid chromatography-photodiode array detection was applied to determination of aflatoxins B(1), B(2) (AFB(1), AFB(2)) in rice, peanut and wheat samples. This research provides an overview of trends related to synthesis of solid phase microextraction (SPME) sorbnents that improves the assay of aflatoxins as the semi-polar compounds in several real samples. It mainly includes summary and a list of the results for a simple carbon nanotube reinforced sol-gel in-fiber device. This device was used for extraction, pre-concentration and determination of aflatoxins B1, B2 in real samples. In this technique carbon nanotube reinforced sol was prepared by the sol-gel method via the reaction of phenyl trimethoxysilane (PTMS) with a basic catalyst (tris hydroxymethyl aminomethan). The influences of microextraction parameters such as pH, ageing time, carbon nanotube contents, desorption conditions, desorption solvent and agitation speed were investigated. Optimal HPLC conditions were: C(18) reversed phase column for separation, water-acetonitril-methanol (35:10:55) as the mobile phase and maximum wavelength for detection was 370 nm. The method was evaluated statistically and under optimized conditions, the detection limits for the analytes were 0.074 and 0.061 ng/mL for B1 and B2 respectively. Limit of quantification for B1 and B2 was 0.1 ng/mL too (n=7). The precisions were in the range of 2.829-2.976% (n=3), and linear ranges were within 0.1 and 400 ng/mL. The method was successfully applied to the analysis of cereals (peanut, wheat, rice) with the relative recoveries from 47.43% to 106.83%. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Global volatile profile of virgin olive oils flavoured by aromatic/medicinal plants.

    PubMed

    Perestrelo, R; Silva, C; Silva, P; Câmara, J S

    2017-07-15

    The global volatile profile of commercial virgin olive oils and flavoured olive oils with aromatic/medicinal plants, was established using liquid-liquid microextraction (LLME) and headspace solid-phase microextraction (HS-SPME) combined with gas chromatography-quadrupole mass spectrometry (GC-qMS). More than 60 volatile organic compounds (VOCs belonging to different groups were identified using both methods. Olive oils volatile profile was slightly influenced by maceration process, which occurred at room temperature (20±2°C) for 15days. The predominant differences were observed in terpenoids group, since some of them were only identified in the flavoured olive oils, while others showed an increase with the maceration process. VOCs mass transfer from plants to olive oils could explain the observed results. Principal components analysis (PCA) applied to LLME/GC-qMS data allowed to distinguish the olive oils. The flavoured oils would increase the use of olive oil among consumers as consequence of the improvement of its aromatic profile and healthy properties. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Validation and Determination of the Contents of Acetaldehyde and Formaldehyde in Foods

    PubMed Central

    Jeong, Hye-Seung; Chung, Hyun; Song, Sang-Hoon; Kim, Cho-Il; Lee, Joon-Goo

    2015-01-01

    The aim of this study was to develop an efficient quantitative method for the determination of acetaldehyde (AA) and formaldehyde (FA) contents in solid and liquid food matrices. The determination of those compounds was validated and performed using gas chromatography-mass spectrometry combined by solid phase micro-extraction after derivatization with O-(2,3,4,5,6-pentafluoro-benzyl)-hydroxylamine hydrochloride. Validation was carried out in terms of limit of detection, limit of quantitation, linearity, precision, and recovery. Then their contents were analyzed in various food samples including 15 fruits, 22 milk products, 31 alcohol-free beverages, and 13 alcoholic beverages. The highest contents of AA and FA were determined in a white wine (40,607.02 ng/g) and an instant coffee (1,522.46 ng/g), respectively. PMID:26483886

  5. Sensitive determination of three aconitum alkaloids and their metabolites in human plasma by matrix solid-phase dispersion with vortex-assisted dispersive liquid-liquid microextraction and HPLC with diode array detection.

    PubMed

    Wang, Xiaozhong; Li, Xuwen; Li, Lanjie; Li, Min; Liu, Ying; Wu, Qian; Li, Peng; Jin, Yongri

    2016-05-01

    A simple and sensitive method for determination of three aconitum alkaloids and their metabolites in human plasma was developed using matrix solid-phase dispersion combined with vortex-assisted dispersive liquid-liquid microextraction and high-performance liquid chromatography with diode array detection. The plasma sample was directly purified by matrix solid-phase dispersion and the eluate obtained was concentrated and further clarified by vortex-assisted dispersive liquid-liquid microextraction. Some important parameters affecting the extraction efficiency, such as type and amount of dispersing sorbent, type and volume of elution solvent, type and volume of extraction solvent, salt concentration as well as sample solution pH, were investigated in detail. Under optimal conditions, the proposed method has good repeatability and reproducibility with intraday and interday relative standard deviations lower than 5.44 and 5.75%, respectively. The recoveries of the aconitum alkaloids ranged from 73.81 to 101.82%, and the detection limits were achieved within the range of 1.6-2.1 ng/mL. The proposed method offered the advantages of good applicability, sensitivity, simplicity, and feasibility, which makes it suitable for the determination of trace amounts of aconitum alkaloids in human plasma samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Development of solid-phase microextraction coupled with liquid chromatography for analysis of tramadol in brain tissue using its molecularly imprinted polymer.

    PubMed

    Habibi-Khorasani, Monireh; Mohammadpour, Amir Hooshang; Mohajeri, Seyed Ahmad

    2017-02-01

    In this work, performance of a molecularly imprinted polymer (MIP) as a selective solid-phase microextraction sorbent for the extraction and enrichment of tramadol in aqueous solution and rabbit brain tissue, is described. Binding properties of MIPs were studied in comparison with their nonimprinted polymer (NIP). Ten milligrams of the optimized MIP was then evaluated as a sorbent, for preconcentration, in molecularly imprinted solid-phase microextraction (MISPME) of tramadol from aqueous solution and rabbit brain tissue. The analytical method was calibrated in the range of 0.004 ppm (4 ng mL -1 ) and 10 ppm (10 μg mL -1 ) in aqueous media and in the ranges of 0.01 and 10 ppm in rabbit brain tissue, respectively. The results indicated significantly higher binding affinity of MIPs to tramadol, in comparison with NIP. The MISPME procedure was developed and optimized with a recovery of 81.12-107.54% in aqueous solution and 76.16-91.20% in rabbit brain tissue. The inter- and intra-day variation values were <8.24 and 5.06%, respectively. Finally the calibrated method was applied for determination of tramadol in real rabbit brain tissue samples after administration of a lethal dose. Our data demonstrated the potential of MISPME for rapid, sensitive and cost-effective sample analysis. Copyright © 2016 John Wiley & Sons, Ltd.

  7. A novel hybrid metal-organic framework-polymeric monolith for solid-phase microextraction.

    PubMed

    Lin, Chen-Lan; Lirio, Stephen; Chen, Ya-Ting; Lin, Chia-Her; Huang, Hsi-Ya

    2014-03-17

    This study describes the fabrication of a novel hybrid metal-organic framework- organic polymer (MOF-polymer) for use as a stationary phase in fritless solid-phase microextraction (SPME) for validating analytical methods. The MOF-polymer was prepared by using ethylene dimethacrylate (EDMA), butyl methacrylate (BMA), and an imidazolium-based ionic liquid as porogenic solvent followed by microwave-assisted polymerization with the addition of 25 % MOF. This novel hybrid MOF-polymer was used to extract penicillin (penicillin G, penicillin V, oxacillin, cloxacillin, nafcillin, dicloxacillin) under different conditions. Quantitative analysis of the extracted penicillin samples using the MOF-organic polymer for SPME was conducted by using capillary electrochromatography (CEC) coupled with UV analysis. The penicillin recovery was 63-96.2 % with high reproducibility, sensitivity, and reusability. The extraction time with the proposed fabricated SPME was only 34 min. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Determination of hydroxyaromatic compounds in water by solid-phase microextraction coupled to high-performance liquid chromatography.

    PubMed

    Wu, Y C; Huang, S D

    1999-03-12

    Solid-phase microextraction (SPME) coupled with high-performance liquid chromatography (HPLC) for the analysis of hydroxyaromatic compounds is described. Three kinds of fibers [50 microns carbowax-templated resin (CW-TPR), 60 microns polydimethylsiloxane-divinylbenzene (PDMS-DVB) and 85 microns polyacrylate (PA) fibers] were evaluated. CW-TPR and PDMS-DVB were selected for further study. The parameters of the desorption procedure (such as desorption mode, the composition of the solvent for desorption and the duration of fiber soaking) were studied and optimized. The effect of the structure and physical properties of analytes, carryover, duration of absorption, temperature of absorption, pH and ionic strength of samples were also investigated. The method was applied to environmental samples (lake water) using a simple calibration curve.

  9. Comparison of different coatings in solid-phase microextraction for the determination of organochlorine pesticides in ground water.

    PubMed

    Pérez-Trujillo, J P; Frías, S; Conde, J E; Rodríguez-Delgado, M A

    2002-07-19

    A solid-phase microextraction (SPME) procedure using three commercialised fibers (Carbowax-divinylbenzene, Carboxen-polydimethylsiloxane and divinylbenzene-Carboxen-polydimethylsiloxane) is presented for the determination of a selected group of organochlorine compounds in water samples. The extraction performances of these compounds were compared using fibers with two and three coatings. The optimal experimental procedures for the adsorption and desorption of pesticides were determined. The limits of detection with the divinylbenzene-Carboxen-polydimethylsiloxane fiber at levels below ng l(-1) were similar or lower than values presented in the literature for several of these compounds using polydimethylsiloxane fiber. The advantages of using this fiber, such as no salt addition, are discussed. Finally, the optimised procedures were applied successfully for the determination of these compounds in polluted ground water samples.

  10. Developing a New Sampling And Analysis Method For Hydrazine And Monomethyl Hydrazine: Using a Derivatizing Agent With Solid Phase Microextraction

    NASA Technical Reports Server (NTRS)

    Allen, John

    2001-01-01

    Solid phase microextraction (SPME) will be used to develop a method for detecting monomethyl hydrazine (MMH) and hydrazine (Hz). A derivatizing agent, pentafluorobenzoyl chloride (PFBCI), is known to react readily with MMH and Hz. The SPME fiber can either be coated with PFBCl and introduced into a gaseous stream containing MMH, or PFBCl and MMH can react first in a syringe barrel and after a short equilibration period a SPME is used to sample the resulting solution. These methods were optimized and compared. Because Hz and MMH can degrade the SPME, letting the reaction occur first gave better results. Only MMH could be detected using either of these methods. Future research will concentrate on constructing calibration curves and determining the detection limit.

  11. ZnO nanorod array polydimethylsiloxane composite solid phase micro-extraction fiber coating: fabrication and extraction capability.

    PubMed

    Wang, Dan; Wang, Qingtang; Zhang, Zhuomin; Chen, Guonan

    2012-01-21

    ZnO nanorod array coating is a novel kind of solid-phase microextraction (SPME) fiber coating which shows good extraction capability due to the nanostructure. To prepare the composite coating is a good way to improve the extraction capability. In this paper, the ZnO nanorod array polydimethylsiloxane (PDMS) composite SPME fiber coating has been prepared and its extraction capability for volatile organic compounds (VOCs) has been studied by headspace sampling the typical volatile mixed standard solution of benzene, toluene, ethylbenzene and xylene (BTEX). Improved detection limit and good linear ranges have been achieved for this composite SPME fiber coating. Also, it is found that the composite SPME fiber coating shows good extraction selectivity to the VOCs with alkane radicals.

  12. Offline solid phase microextraction sampling system

    DOEpatents

    Harvey, Chris A.

    2008-12-16

    An offline solid phase microextraction (SPME) sampling apparatus for enabling SPME samples to be taken a number of times from a previously collected fluid sample (e.g. sample atmosphere) stored in a fused silica lined bottle which keeps volatile organics in the fluid sample stable for weeks at a time. The offline SPME sampling apparatus has a hollow body surrounding a sampling chamber, with multiple ports through which a portion of a previously collected fluid sample may be (a) released into the sampling chamber, (b) SPME sampled to collect analytes for subsequent GC analysis, and (c) flushed/purged using a fluidically connected vacuum source and purging fluid source to prepare the sampling chamber for additional SPME samplings of the same original fluid sample, such as may have been collected in situ from a headspace.

  13. Determination of the boar taint compound skatole in meat juice by means of stable isotope dilution analysis-direct immersion-solid phase microextraction-gas chromatography/mass spectrometry.

    PubMed

    Fischer, Jochen; Brinkmann, Detert; Elsinghorst, Paul W; Wüst, Matthias

    2012-07-01

    A novel SIDA-DI-SPME-GC/MS procedure for the quantitation of skatole in pork meat juice was developed and validated as a substitute for back fat sample analysis. System suitability was evaluated by determining the correlation between skatole concentrations in a subset of 38 paired meat juice and back fat samples selected from 90 fattened boars. High correlation was observed between both matrices and conclusions about the partitioning of skatole as well as of androstenone between fat and lean compartments in vivo were drawn. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Analysis of fatty acid ethyl esters in hair as possible markers of chronically elevated alcohol consumption by headspace solid-phase microextraction (HS-SPME) and gas chromatography-mass spectrometry (GC-MS).

    PubMed

    Pragst, F; Auwaerter, V; Sporkert, F; Spiegel, K

    2001-09-15

    Fatty acid ethyl esters (FAEE) are products of the nonoxidative ethanol metabolism, which are known to be detectable in blood only about 24h after the last alcohol intake. After deposition in hair they should be suitable long-term markers of chronically elevated alcohol consumption. Therefore, a method for the analysis of ethyl myristate, ethyl palmitate, ethyl oleate and ethyl stearate from hair was developed based on the extraction of the hair sample by a dimethylsulphoxide (DMSO)/n-hexane mixture, separation and evaporation of the n-hexane phase and application of headspace solid-phase microextraction (HS-SPME) in combination with gas chromatography-mass spectrometry (GC-MS) to the extract. For use as internal standards, the corresponding D(5)-ethyl esters were prepared. The HS-SPME/GC-MS measurements were automatically performed using a multi-purpose sampler. The detection limits of the FAEE were between 0.01 and 0.04ng/mg and the reproducibility was between 3.5 and 16%. By application of the method to hair samples of 21 fatalities with known heavy alcohol abuse 0.045-2.4ng/mg ethyl myristate, 0.35-13.5ng/mg ethyl palmitate, 0.25-7.7ng/mg ethyl oleate and 0.05-3.85ng/mg ethyl stearate were measured. For social drinkers (30-60g ethanol per week), the concentrations were about one order of magnitude smaller. For 10 teetotalers negative results or traces of ethyl palmitate were found. It was shown by supplementary investigations in single cases that FAEE are also present in sebum, that there is no strong difference in their concentrations between pubic, chest and scalp hair, and that they are detectable in hair segments after a 2 months period of abstinence. From the results follows that the measurement of FAEE concentrations in hair is a useful way for a retrospective detection of alcohol abuse.

  15. Evaluation of gas chromatography-combustion-isotope ratio mass spectrometry (GC-C-IRMS) for the quality assessment of citrus liqueurs.

    PubMed

    Schipilliti, Luisa; Bonaccorsi, Ivana; Cotroneo, Antonella; Dugo, Paola; Mondello, Luigi

    2013-02-27

    Citrus liqueurs are alcoholic beverages obtained by maceration. The European Parliament protects these alcoholic beverages, forbidding the addition of nature-identical flavoring substances. However, for economical and technological reasons, producers often add natural and/or synthetic flavors to the alcoholic syrup, obtaining artificial spirit drinks. The aim of this study is to investigate the authenticity of Italian liqueurs, of lemon, bergamot, and mandarin (locally known as "limoncello", "bargamino", and "mandarinetto"), comparing the carbon isotope ratios with values determined in genuine cold-pressed peel oils. Authenticity assessment was performed using headspace-solid phase microextraction coupled to gas chromatography-combustion-isotope ratio mass spectrometry. Additional analyses were performed by direct enantioselective gas chromatography to determine the enantiomeric distribution of selected chiral volatiles and by gas chromatography-mass spectrometry for the qualitative analyses of the samples. The method allowed confirmation of genuineness. Enantioselective gas chromatography analyses confirmed the results, demonstrating the reliability of the method.

  16. Identification of volatiles from pineapple (Ananas comosus L.) pulp by comprehensive two-dimensional gas chromatography and gas chromatography/mass spectrometry.

    PubMed

    Pedroso, Marcio P; Ferreira, Ernesto C; Hantao, Leandro W; Bogusz, Stanislau; Augusto, Fabio

    2011-07-01

    Combining qualitative data from the chromatographic structure of 2-D gas chromatography with flame ionization detection (GC×GC-FID) and that from gas chromatography-mass spectrometry (GC/MS) should result in a more accurate assignment of the peak identities than the simple analysis by GC/MS, where coelution of analytes is unavoidable in highly complex samples (rendering spectra unsuitable for qualitative purposes) or for compounds in very low concentrations. Using data from GC×GC-FID combined with GC/MS can reveal coelutions that were not detected by mass spectra deconvolution software. In addition, some compounds can be identified according to the structure of the GC×GC-FID chromatogram. In this article, the volatile fractions of fresh and dehydrated pineapple pulp were evaluated. The extraction of the volatiles was performed by dynamic headspace extraction coupled to solid-phase microextraction (DHS-SPME), a technique appropriate for slurries or solid matrices. Extracted analytes were then analyzed by GC×GC-FID and GC/MS. The results obtained using both techniques were combined to improve compound identifications. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Development of a fiber coating based on molecular sol-gel imprinting technology for selective solid-phase micro extraction of caffeine from human serum and determination by gas chromatography/mass spectrometry.

    PubMed

    Rajabi Khorrami, Afshin; Rashidpur, Amene

    2012-05-21

    In this work, a molecular sol-gel imprinting approach has been introduced to produce a fiber coating for selective direct immersion solid-phase microextraction (SPME) of caffeine. The polymerization mixture was composed of vinyl trimethoxysilane and methacrylic acid as vinyl sol-gel precursor and functional monomer, respectively. Caffeine was used as template molecule during polymerization process. The prepared fibers could be coupled directly to gas chromatography/mass spectrometry (GC/MS) and used for trace analysis of caffeine in a complex sample such as human serum. The parameters influencing SPME such as time, temperature and stirring speed were optimized. The prepared coating showed good selectivity towards caffeine in the presence of some structurally related compounds. Also, it offered high imprinting capability in comparison to bare fiber and non-imprinted coating. Linear range for caffeine detection was 1-80 μg mL(-1) and the limit of detection was 0.1 μg mL(-1). The intra-day and inter-day precisions of the peak areas for five replicates were 10 and 16%, respectively. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Application of headspace solid phase microextraction for study of noncovalent interaction of borneol with human serum albumin

    PubMed Central

    Hu, Liang; Chen, Dong-ying

    2009-01-01

    Aim: To investigate noncovalent interactions between borneol and human serum albumin (HSA) under near-physiological conditions. Methods: A 65-μm polydimethylsiloxane (PDMS) fiber was selected for sampling. The extraction temperature was kept at 37 °C, and the extraction time was optimized at 10 min. Borneol solutions of different concentrations were equilibrated in 600 μmol/L HSA and 67 mmol/L phosphate buffer solution (pH 7.4, 37 °C) for 24 h prior to solid phase microextraction (SPME) using headspace mode. The binding properties were obtained based on the calculation of extracted borneol amount using gas chromatography (GC) determination. Results: The headspace SPME extraction method avoided disturbance from the HSA binding matrix. The recovery showed good linearity for the borneol concentrations over the range of 0.4–16.3 μmol/L with a regression coefficient (R2) of 0.9998. The limit of detection and lower limit of quantitation were determined to be 0.01 μmol/L and 0.4 μmol/L, respectively. The binding constant and the percentage binding rate were estimated to be 2.4×103(mol/L)-1 and 59.5%, respectively. Conclusion: Headspace SPME coupled to GC is a simple, sensitive and rapid method for the study of borneol binding to HSA. The method may be applied in the determination of other protein binding properties in human plasma. PMID:19890364

  19. Volatile fingerprints of seeds of four species indicate the involvement of alcoholic fermentation, lipid peroxidation, and Maillard reactions in seed deterioration during ageing and desiccation stress

    PubMed Central

    Colville, Louise

    2012-01-01

    The volatile compounds released by orthodox (desiccation-tolerant) seeds during ageing can be analysed using gas chromatography–mass spectrometry (GC-MS). Comparison of three legume species (Pisum sativum, Lathyrus pratensis, and Cytisus scoparius) during artificial ageing at 60% relative humidity and 50 °C revealed variation in the seed volatile fingerprint between species, although in all species the overall volatile concentration increased with storage period, and changes could be detected prior to the onset of viability loss. The volatile compounds are proposed to derive from three main sources: alcoholic fermentation, lipid peroxidation, and Maillard reactions. Lipid peroxidation was confirmed in P. sativum seeds through analysis of malondialdehyde and 4-hydroxynonenal. Volatile production by ageing orthodox seeds was compared with that of recalcitrant (desiccation-sensitive) seeds of Quercus robur during desiccation. Many of the volatiles were common to both ageing orthodox seeds and desiccating recalcitrant seeds, with alcoholic fermentation forming the major source of volatiles. Finally, comparison was made between two methods of analysis; the first used a Tenax adsorbent to trap volatiles, whilst the second used solid phase microextraction to extract volatiles from the headspace of vials containing powdered seeds. Solid phase microextraction was found to be more sensitive, detecting a far greater number of compounds. Seed volatile analysis provides a non-invasive means of characterizing the processes involved in seed deterioration, and potentially identifying volatile marker compounds for the diagnosis of seed viability loss. PMID:23175670

  20. Determination of hydrazine in drinking water: Development and multivariate optimization of a rapid and simple solid phase microextraction-gas chromatography-triple quadrupole mass spectrometry protocol.

    PubMed

    Gionfriddo, Emanuela; Naccarato, Attilio; Sindona, Giovanni; Tagarelli, Antonio

    2014-07-04

    In this work, the capabilities of solid phase microextraction were exploited in a fully optimized SPME-GC-QqQ-MS analytical approach for hydrazine assay. A rapid and easy method was obtained by a simple derivatization reaction with propyl chloroformate and pyridine carried out directly in water samples, followed by automated SPME analysis in the same vial without further sample handling. The affinity of the different derivatized compounds obtained towards five commercially available SPME coatings was evaluated, in order to achieve the best extraction efficiency. GC analyses were carried out using a GC-QqQ-MS instrument in selected reaction monitoring (SRM) acquisition mode which has allowed the achievement of high specificity by selecting appropriate precursor-product ion couples improving the capability in analyte identification. The multivariate approach of experimental design was crucial in order to optimize derivatization reaction, SPME process and tandem mass spectrometry parameters. Accuracy of the proposed protocol, tested at 60, 200 and 800 ng L(-1), provided satisfactory values (114.2%, 83.6% and 98.6%, respectively), whereas precision (RSD%) at the same concentration levels were of 10.9%, 7.9% and 7.7% respectively. Limit of detection and quantification of 4.4 and 8.3 ng L(-1) were obtained. The reliable application of the proposed protocol to real drinking water samples confirmed its capability to be used as analytical tool for routine analyses. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. SOLID PHASE MICROEXTRACTION SAMPLING OF FIRE DEBRIS RESIDUES IN THE PRESENCE OF RADIONUCLIDE SURROGATE METALS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duff, M; Keisha Martin, K; S Crump, S

    2007-03-23

    The Federal Bureau of Investigation (FBI) Laboratory currently does not have on site facilities for handling radioactive evidentiary materials and there are no established FBI methods or procedures for decontaminating highly radioactive fire debris (FD) evidence while maintaining evidentiary value. One experimental method for the isolation of FD residue from radionuclide metals involves using solid phase microextraction (SPME) fibers to remove the residues of interest. Due to their high affinity for organics, SPME fibers should have little affinity for most (radioactive) metals. The focus of this research was to develop an examination protocol that was applicable to safe work inmore » facilities where high radiation doses are shielded from the workers (as in radioactive shielded cells or ''hot cells''). We also examined the affinity of stable radionuclide surrogate metals (Co, Ir, Re, Ni, Ba, Cs, Nb, Zr and Nd) for sorption by the SPME fibers. This was done under exposure conditions that favor the uptake of FD residues under conditions that will provide little contact between the SPME and the FD material (such as charred carpet or wood that contains commonly-used accelerants). Our results from mass spectrometric analyses indicate that SPME fibers show promise for use in the room temperature head space uptake of organic FD residue (namely, diesel fuel oil, kerosene, gasoline and paint thinner) with subsequent analysis by gas chromatography (GC) with mass spectrometric (MS) detection. No inorganic forms of ignitable fluids were included in this study.« less

  2. Determination of Aromatic Amines Using Solid-Phase Microextraction Based on an Ionic Liquid-Mediated Sol–Gel Technique

    PubMed Central

    Abbasi, Vajihe; Sarafraz-Yazdi, Ali; Amiri, Amirhassan; Vatani, Hossein

    2016-01-01

    A headspace solid-phase microextraction (HS-SPME) method was developed for isolation of monocyclic aromatic amines from water samples followed by gas chromatography–flame ionization detector (GC–FID). In this work, the effect of the presence of ionic liquid (namely, 1-hexyl-3-methyl-imidazolium hexafluorophosphate [C6MIM][PF6]) was investigated in the sol–gel coating solutions on the morphology and extraction behavior of the resulting hybrid organic–inorganic sol–gel sorbents utilized in SPME. Hydroxy-terminated poly(dimethylsiloxane) (PDMS) was used as the sol–gel active organic component for sol–gel hybrid coatings. Two different coated fibers that were prepared are PDMS and PDMS-IL ([C6MIM][PF6]) fibers. Under the optimal conditions, the method detection limits (S/N = 3) with PDMS-IL were in the range of 0.001–0.1 ng/mL and the limits of quantification (S/N = 10) between 0.005 and 0.5 ng/mL. The relative standard deviations for one fiber (n = 5) were obtained from 3.1 up to 8.5% and between fibers or batch to batch (n = 3) in the range of 5.3–10.1%. The developed method was successfully applied to real water and juice fruits samples while the relative recovery percentages obtained for the spiked water samples at 0.1 ng/mL were from 83.3 to 95.0%. PMID:26759488

  3. Orthogonal Design Study on Factors Affecting the Determination of Common Odors in Water Samples by Headspace Solid-Phase Microextraction Coupled to GC/MS

    PubMed Central

    Ding, Zhen; Xia, Weiwen; Zheng, Hao; Xia, Yuting; Chen, Xiaodong

    2013-01-01

    Geosmin and 2-MIB are responsible for the majority of earthy and musty events related to the drinking water. These two odorants have extremely low odor threshold concentrations at ng L−1 level in the water, so a simple and sensitive method for the analysis of such trace levels was developed by headspace solid-phase microextraction coupled to gas chromatography/mass spectrometry. In this study, the orthogonal experiment design L32 (49) was applied to arrange and optimize experimental conditions. The optimum was the following: temperatures of extraction and desorption, 65°C and 260°C, respectively; times of extraction and desorption, 30 min and 5 min, respectively; ionic strength, 25% (w/v); rotate-speed, 600 rpm; solution pH, 5.0. Under the optimized conditions, limits of detection (S/N = 3) were 0.04 and 0.13 ng L−1 for geosmin and 2-MIB, respectively. Calculated calibration curves gave high levels of linearity with a correlation coefficient value of 0.9999 for them. Finally, the proposed method was applied to water samples, which were previously analyzed and confirmed to be free of target analytes. Besides, the proposal method was applied to test environmental water samples. The RSDs were 2.75%~3.80% and 4.35%~7.6% for geosmin and 2-MIB, respectively, and the recoveries were 91%~107% and 91%~104% for geosmin and 2-MIB, respectively. PMID:24000317

  4. Preparation by low-temperature nonthermal plasma of graphite fiber and its characteristics for solid-phase microextraction.

    PubMed

    Luo, Fan; Wu, Zucheng; Tao, Ping; Cong, Yanqing

    2009-01-05

    Low-temperature nonthermal plasma has been used to prepare solid-phase microextraction (SPME) fibers with high adsorbability, long-term serviceability, and high reproducibility. Graphite rods serving as fiber precursors were treated by an air plasma discharged at 15.2-15.5 kV for a duration of 8 min. Sampling results revealed that the adsorptive capacity of the homemade fiber was 2.5-34.6 times that of a polyacrylate (PA) fiber for alcohols (methanol, ethanol, isopropyl alcohol, n-butyl alcohol), and about 1.4-1.6 times and 2.5-5.1 times that of an activated carbon fiber (ACF) for alcohols and BTEX (benzene, toluene, ethylbenzene, and xylenes), respectively. It is confirmed from FTIR (Fourier transform infrared spectrophotometer) and SEM (scanning electron microscope) analyses that the improvement in the adsorptive performance attributed to increased surface energy and roughness of the graphite fiber. Using gas chromatography (GC)-flame-ionization detector (FID), the limits of detection (LODs) of the alcohols and BTEX ranged between 0.19 and 3.75 microg L(-1), the linear ranges were between 0.6 and 35,619 microg L(-1) with good linearity (R(2)=0.9964-0.9997). It was demonstrated that nonthermal plasma offers a fast and simple method for preparing an efficient graphite SPME fiber, and that SPME using the homemade fiber represents a sensitive and selective extraction method for the analysis of a wide range of organic compounds.

  5. Analysis of beer volatiles by polymeric imidazolium-solid phase microextraction coatings: Synthesis and characterization of polymeric imidazolium ionic liquids.

    PubMed

    González-Álvarez, Jaime; Blanco-Gomis, Domingo; Arias-Abrodo, Pilar; Pello-Palma, Jairo; Ríos-Lombardía, Nicolás; Busto, Eduardo; Gotor-Fernández, Vicente; Gutiérrez-Álvarez, María Dolores

    2013-08-30

    Two polymeric ionic liquids, 3-(but-3″-en-1″-yl)-1-[2'-hydroxycyclohexyl]-1H-imidazol-3-ium bis(trifluoromethanesulfonyl)imide (IL-1) and 1-(2'-hydroxycyclohexyl)-3-(4″-vinylbenzyl)-1H-imidazol-3-ium bis(trifluoromethylsulfonyl)imide (IL-2), have been synthesized by a free radical polymerization reaction and used as coatings for solid-phase microextraction (SPME). These new fibers exhibit good film stability, high thermal stability (270-290°C) and long lifetimes, and are used for the extraction of volatile compounds in lemon beer using gas chromatography separation and flame ionization detection. The scanning electron micrographs of the fiber surface revealed a polymeric ionic liquid (PIL) film, which is distributed homogeneously on the fiber. The developed PIL fiber showed good linearity between 50 and 2000μg/L with regression coefficients in the range of 0.996-0.999. The relative standard deviations (RSD) obtained in the peak area were found to vary between 1% and 12%, which assured that adequate repeatability was achieved. The spiked recoveries for three beer samples ranged from 78.4% to 123.6%. Experimental design has been employed in the optimization of extraction factors and robustness assessment. The polymeric IL-1 butenyl fiber showed a greater efficiency compared to the PDMS-DVB (65μm) and CAR-PDMS (75μm) for the extraction of all of the analytes studied. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  6. Preparation of a polymeric ionic liquid-coated solid-phase microextraction fiber by surface radical chain-transfer polymerization with stainless steel wire as support.

    PubMed

    Feng, Juanjuan; Sun, Min; Xu, Lili; Li, Jubai; Liu, Xia; Jiang, Shengxiang

    2011-10-28

    Polymeric 1-vinyl-3-octylimidazolium hexafluorophosphate was synthesized in situ on stainless steel wire by surface radical chain-transfer polymerization and used as sensitive coatings in solid-phase microextraction. The outer surface of the stainless steel wire was firstly coated with microstructured silver layer via silver mirror reaction and then functionalized with self-assembled monolayers of 1,8-octanedithiol, which acted as chain transfer agent in the polymerization. Coupled to gas chromatography, extraction performance of the fiber was studied with both headspace and direct-immersion modes using benzene, toluene, ethylbenzene and xylenes (BTEX), phenols and polycyclic aromatic hydrocarbon (PAHs) as model analytes. In combination with the microstructured silver layer, the PIL-coated fiber exhibited high extraction efficiency. Linear ranges for BTEX with headspace mode were in the range of 0.2-1000 μg L(-1) for benzene, and 0.1-1000 μg L(-1) for toluene, ethylbenzene and xylenes. Limits of detection (LODs) were from 0.02 to 0.05 μg L(-1). Wide linear ranges of direct-immersion mode for the extraction of several phenols and PAHs were also obtained with correlation coefficients (R) from 0.9943 to 0.9997. The proposed fiber showed good durability with long lifetime. RSDs of 56 times extraction were still in an acceptable range, from 8.85 to 22.8%. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Sol-gel approach for fabrication of coated anodized titanium wire for solid-phase microextraction: highly efficient adsorbents for enrichment of trace polar analytes.

    PubMed

    Jia, Jing; Xu, Lili; Wang, Shuai; Wang, Licheng; Liu, Xia

    2014-05-01

    Nanotubular titania film was prepared in situ on titanium wire and was used as the fiber substrate for solid-phase microextraction (SPME) because of its high surface-to-volume ratio, easy preparation, and mechanical stability. Three different functional coatings, β-cyclodextrin (β-CD), β-cyclodextrin-co-poly(ethylenepropylene glycol) (β-CD/PEG), and polyethylene glycol (PEG)-based sorbents were chemically bonded to the nanostructured wire surface via sol-gel technology to further enhance the absorbing capability and extraction selectivity. Coupled to gas chromatography-flame ionic detection (GC-FID), the prepared SPME fibers were investigated using diverse compounds. The results indicated that the fibers showed good mechanical strength, excellent thermal stability, and wonderful capacity and selectivity to polar compounds, including polar aromatic compounds, alcohols, and ketones. Combining the superior hydrophilic property of a bonded functional molecule and the highly porous structure of a fiber coating, the prepared PEG-coated SPME fiber showed much higher adsorption affinity to ephedrine and methylephedrine than β-CD and β-CD/PEG fibers. The as-established PEG-coated SPME-GC analytical method provided excellent sensitivity (LODs, 0.004 and 0.001 ng mL(-1) for ephedrine and methylephedrine, respectively) and better linear range (0.01-2 000 μg L(-1)). In addition, it has surprising repeatability and reproducibility. Finally, the present approach was used to analyze ephedrine and methylephedrine from real urine samples, and reliable results were obtained.

  8. Monolithic graphene fibers for solid-phase microextraction.

    PubMed

    Fan, Jing; Dong, Zelin; Qi, Meiling; Fu, Ruonong; Qu, Liangti

    2013-12-13

    Monolithic graphene fibers for solid-phase microextraction (SPME) were fabricated through a dimensionally confined hydrothermal strategy and their extraction performance was evaluated. For the fiber fabrication, a glass pipeline was innovatively used as a hydrothermal reactor instead of a Teflon-lined autoclave. Compared with conventional methods for SPME fibers, the proposed strategy can fabricate a uniform graphene fiber as long as several meters or more at a time. Coupled to capillary gas chromatography (GC), the monolithic graphene fibers in a direct-immersion (DI) mode achieved higher extraction efficiencies for aromatics than those for n-alkanes, especially for polycyclic aromatic hydrocarbons (PAHs), thanks to π-π stacking interaction and hydrophobic effect. Additionally, the fibers exhibited excellent durability and can be repetitively used more than 160 times without significant loss of extraction performance. As a result, an optimum extraction condition of 40°C for 50min with 20% NaCl (w/w) was finally used for SPME of PAHs in aqueous samples. For the determination of PAHs in water samples, the proposed DI-SPME-GC method exhibited linear range of 0.05-200μg/L, limits of detection (LOD) of 4.0-50ng/L, relative standard deviation (RSD) less than 9.4% and 12.1% for one fiber and different fibers, respectively, and recoveries of 78.9-115.9%. The proposed method can be used for analysis of PAHs in environmental water samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Determination of volatile polycyclic aromatic hydrocarbons in waters using headspace solid-phase microextraction with a benzyl-functionalized crosslinked polymeric ionic liquid coating.

    PubMed

    Merdivan, Melek; Pino, Verónica; Anderson, Jared L

    2017-08-01

    A benzyl-functionalized crosslinked polymeric ionic liquid (PIL), produced through the co-polymerization of the 1-vinylbenzyl-3-hexadecylimidazolium bis[(trifluoromethyl)sulfonyl]imide (VBHDIM-NTf 2 ) ionic liquid (IL) monomer and 1,12-di(3-vinylbenzylimidazolium)dodecane bis[(trifluoromethyl)sulfonyl]imide ((DVBIM) 2 C 12- 2NTf 2 ) IL crosslinker, was successfully used as a sorbent coating in headspace solid-phase microextraction (SPME) coupled to gas chromatography (GC) with flame-ionization detection (FID) to determine seven volatile polycyclic aromatic hydrocarbons (PAHs) in environmental water samples. Optimum extraction conditions for the PAHs when using the novel sorbent include an extraction temperature of 50°C, an ionic strength content adjusted with 30% (w/v) NaCl in the aqueous sample, and an extraction time of 60 min. The extraction performance of the crosslinked PIL fiber was compared to the SPME commercial coating polydimethylsiloxane fiber. The calibration ranges of the studied PAHs were linear in the range of 0.02-20 µg L -1 for the crosslinked PIL fiber. The accuracy of the proposed method was demonstrated by examining the spiked recoveries of seven PAHs which produced values ranging from 67.2% to 130% (for river- and seawater samples), and precision values lower than 9.4% for a spiked level of 1 µg L -1 , and detection limits between 0.01 and 0.04 µg L -1 , which supports the sensitivity of the method using GC-FID.

  10. Preparation of C18 composite solid-phase microextraction fiber and its application to the determination of organochlorine pesticides in water samples.

    PubMed

    Li, Siyan; Lu, Chengwei; Zhu, Fang; Jiang, Ruifen; Ouyang, Gangfeng

    2015-05-11

    In this work, a C18 composite solid-phase microextraction (SPME) fiber was prepared with a new method and applied to the analysis of organochlorine pesticides (OCPs) in water sample. A stainless steel wire (o.d. 127 μm) was used as the substrate, and a mixture of the C18 particle (3.5 μm) and the 184 silicone was used as the coating material. During the process of fiber preparation, a section of capillary column was used to fix the mixture onto the stainless steel wire and to ensure the constant of coating thickness. The prepared fiber showed excellent thermal stability and solvent resistance. By coupling with gas chromatography-mass spectrometry (GC-MS), the fiber exhibited wide linearity (2-500 ng L(-1)) and good sensitivity for the determination of six OCPs in water samples, the OCPs tested included hexachlorobezene, trans-chlordane, cis-chlordane, o,p-DDT, p,p-DDT and mirex. Not only the extraction performance of the newly prepared fiber was more than seven times higher than those of commercial fibers, the limits of detections (LODs) (0.059-0.151 ng L(-1)) for OCPs achieved under optimized conditions were also lower than those of reported SPME methods. The fiber was successfully applied to the determination of OCPs in real water samples by using developed SPME-GC-MS method. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Fast analysis of glycosides based on HKUST-1-coated monolith solid-phase microextraction and direct analysis in real-time mass spectrometry.

    PubMed

    Li, Xianjiang; Wang, Xin; Ma, Wen; Ai, Wanpeng; Bai, Yu; Ding, Li; Liu, Huwei

    2017-04-01

    Glycosides are a kind of highly important natural aromatic precursors in tobacco leaves. In this study, a novel HKUST-1-coated monolith dip-it sampler was designed for the fast and sensitive analysis of trace glycosides using direct analysis in real-time mass spectrometry. This device was prepared in two steps: in situ polymerization of monolith in a glass capillary of dip-it and layer-by-layer growth of HKUST-1 on the surface of monolith. Sufficient extraction was realized by immersing the tip to solution and in situ desorption was carried out by plasma direct analysis in real time. Compared with traditional solid-phase microextraction protocols, sample desorption was not needed anymore, and only extraction conditions were needed to be optimized in this method, including the gas temperature of direct analysis in real time, extraction time, and CH 3 COONH 4 additive concentration. This method enabled the simultaneous detection of six kinds of glycosides with the limits of detection of 0.02-0.05 μg/mL and the linear ranges covering two orders of magnitude with the limits of quantitation of 0.05-0.1 μg/mL. Moreover, the developed method was applied for the glycosides analysis of three tobacco samples, which only took about 2 s for every sample. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Simultaneous derivatisation and preconcentration of parabens in food and other matrices by isobutyl chloroformate and dispersive liquid-liquid microextraction followed by gas chromatographic analysis.

    PubMed

    Jain, Rajeev; Mudiam, Mohana Krishna Reddy; Chauhan, Abhishek; Ch, Ratnasekhar; Murthy, R C; Khan, Haider A

    2013-11-01

    A simple, rapid and economical method has been proposed for the quantitative determination of parabens (methyl, ethyl, propyl and butyl paraben) in different samples (food, cosmetics and water) based on isobutyl chloroformate (IBCF) derivatisation and preconcentration using dispersive liquid-liquid microextraction in single step. Under optimum conditions, solid samples were extracted with ethanol (disperser solvent) and 200 μL of this extract along with 50 μL of chloroform (extraction solvent) and 10 μL of IBCF was rapidly injected into 2 mL of ultra-pure water containing 150 μL of pyridine to induce formation of a cloudy state. After centrifugation, 1 μL of the sedimented phase was analysed using gas chromatograph-flame ionisation detector (GC-FID) and the peaks were confirmed using gas chromatograph-positive chemical ionisation-mass spectrometer (GC-PCI-MS). Method was found to be linear over the range of 0.1-10 μg mL(-1) with square of correlation coefficient (R(2)) in the range of 0.9913-0.9992. Limit of detection (LOD) and limit of quantification (LOQ) were found to be 0.029-0.102 μg mL(-1) and 0.095-0.336 μg mL(-1) with a signal to noise ratio of 3:1 and 10:1, respectively. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Improved quantification of livestock associated odorous volatile organic compounds in a standard flow-through system using solid-phase microextraction and gas chromatography-mass spectrometry.

    PubMed

    Yang, Xiuyan; Zhu, Wenda; Koziel, Jacek A; Cai, Lingshuang; Jenks, William S; Laor, Yael; Leeuwen, J Hans van; Hoff, Steven J

    2015-10-02

    Aerial emissions of odorous volatile organic compounds (VOCs) are an important nuisance factor from livestock production systems. Reliable air sampling and analysis methods are needed to develop and test odor mitigation technologies. Quantification of VOCs responsible for livestock odor remains an analytical challenge due to physicochemical properties of VOCs and the requirement for low detection thresholds. A new air sampling and analysis method was developed for testing of odor/VOCs mitigation in simulated livestock emissions system. A flow-through standard gas generating system simulating odorous VOCs in livestock barn emissions was built on laboratory scale and tested to continuously generate ten odorous VOCs commonly defining livestock odor. Standard VOCs included sulfur VOCs (S-VOCs), volatile fatty acids (VFAs), and p-cresol. Solid-phase microextraction (SPME) was optimized for sampling of diluted odorous gas mixtures in the moving air followed by gas chromatography-mass spectrometry (GC-MS) analysis. CAR/PDMS 85μm fiber was shown to have the best sensitivity for the target odorous VOCs. A practical 5-min sampling time was selected to ensure optimal extraction of VFAs and p-cresol, as well as minimum displacement of S-VOCs. Method detection limits ranged from 0.39 to 2.64ppbv for S-VOCs, 0.23 to 0.77ppbv for VFAs, and 0.31ppbv for p-cresol. The method developed was applied to quantify VOCs and odorous VOC mitigation with UV light treatment. The measured concentrations ranged from 20.1 to 815ppbv for S-VOCs, 10.3 to 315ppbv for VFAs, and 4.73 to 417ppbv for p-cresol. Relative standard deviations between replicates ranged from 0.67% to 12.9%, 0.50% to 11.4%, 0.83% to 5.14% for S-VOCs, VFAs, and p-cresol, respectively. This research shows that a simple manual SPME sampler could be used successfully for quantification of important classes of odorous VOCs at concentrations relevant for real aerial emissions from livestock operations. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Bis(trifluoromethylsulfonyl)imide-based frozen ionic liquid for the hollow-fiber solid-phase microextraction of dichlorodiphenyltrichloroethane and its main metabolites.

    PubMed

    Pang, Long; Yang, Peijie; Pang, Rong; Li, Shunyi

    2017-08-01

    1-Hexadecyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide is a solid-phase ionic organic material under ambient temperature and is considered as a kind of "frozen" ionic liquid. Because of their solid-state and ultra-hydrophobicity, "frozen" ionic liquids are able to be confined in the pores of hollow fiber, based on which a simple method was developed for the hollow-fiber solid-phase microextraction of dichlorodiphenyltrichloroethane and its main metabolites. Under optimized conditions, the proposed method results in good linearity (R 2 > 0.9965) over the range of 0.5-50 μg/L, with low limits of detection and quantification in the range of 0.33-0.38 and 1.00-1.25 μg/L, respectively. Intra- and interday precisions evaluated by relative standard deviation were 3-6 and 1-6%, respectively. The spiked recoveries of dichlorodiphenyltrichloroethane and its main metabolites from real water samples were in the range of 64-113 and 79-112%, respectively, at two different concentration levels. The results suggest that "frozen" ionic liquids are promising for use as a class of novel sorbents. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Solid phase microextraction of macrolide, trimethoprim, and sulfonamide antibiotics in wastewaters.

    PubMed

    McClure, Evelyn L; Wong, Charles S

    2007-10-26

    In this work, we optimize a solid phase microextraction (SPME) method for the simultaneous collection of antibiotics (sulfonamides, macrolides, and trimethoprim) present in wastewaters. The performance of the SPME method is compared to a solid phase extraction (SPE) method. Analytes in both cases were quantified by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS-MS) with electrospray ionization. The advantages offered by SPME in this application are: decreased sample volume requirements, ease of sample processing and extraction, decreased cost, and most importantly, elimination of electrospray matrix effects. Despite having higher limits of quantification (16-1380 ng/L in influent and 35-260 ng/L in effluent), nearly all of the compounds found to be present in Edmonton Gold Bar wastewater by SPE were measurable by SPME (i.e., sulfamethoxazole, trimethoprim, erythromycin, and clarithromycin), with values similar to those obtained using the former method. Limits of quantification for the SPE method for the measured compounds were 4.7-15 ng/L and 0.86-6.1 ng/L for influent and effluent, respectively.

  16. Electrochemical luminescence determination of hyperin using a sol-gel@graphene luminescent composite film modified electrode for solid phase microextraction

    NASA Astrophysics Data System (ADS)

    Zou, Xiaojun; Shang, Fang; Wang, Sui

    2017-02-01

    In this paper, a novel electrochemiluminescence (ECL) sensor of sol-gel@graphene luminescent composite film modified electrode for hyperin determination was prepared using graphene (G) as solid-phase microextraction (SPME) material, based on selective preconcentration of target onto an electrode and followed by luminol ECL detection. Hyperin was firstly extracted from aqueous solution through the modified GCE. Hydrogel, electrogenerated chemiluminescence reagents, pH of working solution, extraction time and temperature and scan rate were discussed. Under the optimum conditions, the change of ECL intensity was in proportion to the concentration of hyperin in the range of 0.02-0.24 μg/mL with a detection limit of 0.01 μg/mL. This method showed good performance in stability, reproducibility and precision for the determination of hyperin.

  17. [The study of carbonaceous adsorbent for solid-phase microextraction and the comparison with commercial device].

    PubMed

    Fang, R; Zhang, W; Wang, J; Zhang, K; Nai, Z

    1999-09-01

    The parameters governing solid-phase microextraction have been investigated, and the development of carbonaceous adsorbent for SPME is presented because it is durable and inexpensive. The time profile curves were determined for several organic pesticides having a wide range of water solubilities and the effect of salt was also investigated. The method of SPME-GC-ECD to analyse trace level of the organic pesticide in water is established by the determination of optimum parameters. The comparison with commercial SPME device shows that the carbonaceous adsorbent having been treated with physical or chemical method for SPME can get lower limits of detection than polyacrylate and polydimethylsiloxane, although there are still some work to be done to improve its precision. The results shows that this new SPME device has great application potential.

  18. Solid-Phase Microextraction Coupled to Capillary Atmospheric Pressure Photoionization-Mass Spectrometry for Direct Analysis of Polar and Nonpolar Compounds.

    PubMed

    Mirabelli, Mario F; Zenobi, Renato

    2018-04-17

    A novel capillary ionization source based on atmospheric pressure photoionization (cAPPI) was developed and used for the direct interfacing between solid-phase microextraction (SPME) and mass spectrometry (MS). The efficiency of the source was evaluated for direct and dopant-assisted photoionization, analyzing both polar (e.g., triazines and organophosphorus pesticides) and nonpolar (polycyclic aromatic hydrocarbons, PAHs) compounds. The results show that the range of compound polarity, which can be addressed by direct SPME-MS can be substantially extended by using cAPPI, compared to other sensitive techniques like direct analysis in real time (DART) and dielectric barrier discharge ionization (DBDI). The new source delivers a very high sensitivity, down to sub parts-per-trillion (ppt), making it a viable alternative when compared to previously reported and less comprehensive direct approaches.

  19. Solid-phase microextraction technology for in vitro and in vivo metabolite analysis

    PubMed Central

    Zhang, Qihui; Zhou, Liandi; Chen, Hua; Wang, Chong-Zhi; Xia, Zhining; Yuan, Chun-Su

    2016-01-01

    Analysis of endogenous metabolites in biological samples may lead to the identification of biomarkers in metabolomics studies. To achieve accurate sample analysis, a combined method of continuous quick sampling and extraction is required for online compound detection. Solid-phase microextraction (SPME) integrates sampling, extraction and concentration into a single solvent-free step for chemical analysis. SPME has a number of advantages, including simplicity, high sensitivity and a relatively non-invasive nature. In this article, we reviewed SPME technology in in vitro and in vivo analyses of metabolites after the ingestion of herbal medicines, foods and pharmaceutical agents. The metabolites of microorganisms in dietary supplements and in the gastrointestinal tract will also be examined. As a promising technology in biomedical and pharmaceutical research, SPME and its future applications will depend on advances in analytical technologies and material science. PMID:27695152

  20. Inorganic-organic hybrid coating material for the online in-tube solid-phase microextraction of monohydroxy polycyclic aromatic hydrocarbons in urine.

    PubMed

    Wang, ShuLing; Xu, Hui

    2016-12-01

    An inorganic-organic hybrid nanocomposite (zinc oxide/polypyrrole) that represents a novel kind of coating for in-tube solid-phase microextraction is reported. The composite coating was prepared by a facile electrochemical polymerization strategy on the inner surface of a stainless-steel tube. Based on the coated tube, a novel online in-tube solid-phase microextraction with liquid chromatography and mass spectrometry method was developed and applied for the extraction of three monohydroxy polycyclic aromatic hydrocarbons in human urine. The coating displayed good extraction ability toward monohydroxy polycyclic aromatic hydrocarbons. In addition, long lifespan, excellent stability, and good compression resistance were also obtained for the coating. The experimental conditions affecting the extraction were optimized systematically. Under the optimal conditions, the limits of detection and quantification were in the range of 0.039-0.050 and 0.130-0.167 ng/mL, respectively. Good linearity (0.2-100 ng/mL) was obtained with correlation coefficients larger than 0.9967. The repeatability, expressed as relative standard deviation, ranged between 2.5% and 9.4%. The method offered the advantage of process simplicity, rapidity, automation, and sensitivity in the analysis of human urinary monohydroxy polycyclic aromatic hydrocarbons in two different cities of Hubei province. An acceptable recovery of monohydroxy polycyclic aromatic hydrocarbons (64-122%) represented the additional attractive features of the method in real urine analysis. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Trace determination of five triazole fungicide residues in traditional Chinese medicine samples by dispersive solid-phase extraction combined with ultrasound-assisted dispersive liquid-liquid microextraction and UHPLC-MS/MS.

    PubMed

    Ma, Shuping; Yuan, Xucan; Zhao, Pengfei; Sun, Hong; Ye, Xiu; Liang, Ning; Zhao, Longshan

    2017-08-01

    A novel and reliable method for determination of five triazole fungicide residues (triadimenol, tebuconazole, diniconazole, flutriafol, and hexaconazol) in traditional Chinese medicine samples was developed using dispersive solid-phase extraction combined with ultrasound-assisted dispersive liquid-liquid microextraction before ultra-high performance liquid chromatography with tandem mass spectrometry. The clean up of the extract was conducted using dispersive solid-phase extraction by directly adding sorbents into the extraction solution, followed by shaking and centrifugation. After that, a mixture of 400 μL trichloromethane (extraction solvent) and 0.5 mL of the above supernatant was injected rapidly into water for the dispersive liquid-liquid microextraction procedure. The factors affecting the extraction efficiency were optimized. Under the optimum conditions, the calibration curves showed good linearity in the range of 2.0-400 (tebuconazole, diniconazole, and hexaconazole) and 4.0-800 ng/g (triadimenol and flutriafol) with the regression coefficients higher than 0.9958. The limit of detection and limit of quantification for the present method were 0.5-1.1 and 1.8-4.0 ng/g, respectively. The recoveries of the target analytes ranged from 80.2 to 103.2%. The proposed method has been successfully applied to the analysis of five triazole fungicides in traditional Chinese medicine samples, and satisfactory results were obtained. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Dispersive solid-phase extraction followed by vortex-assisted dispersive liquid-liquid microextraction based on the solidification of a floating organic droplet for the determination of benzoylurea insecticides in soil and sewage sludge.

    PubMed

    Peng, Guilong; He, Qiang; Mmereki, Daniel; Lu, Ying; Zhong, Zhihui; Liu, Hanyang; Pan, Weiliang; Zhou, Guangming; Chen, Junhua

    2016-04-01

    A novel dispersive solid-phase extraction combined with vortex-assisted dispersive liquid-liquid microextraction based on solidification of floating organic droplet was developed for the determination of eight benzoylurea insecticides in soil and sewage sludge samples before high-performance liquid chromatography with ultraviolet detection. The analytes were first extracted from the soil and sludge samples into acetone under optimized pretreatment conditions. Clean-up of the extract was conducted by dispersive solid-phase extraction using activated carbon as the sorbent. The vortex-assisted dispersive liquid-liquid microextraction based on solidification of floating organic droplet procedure was performed by using 1-undecanol with lower density than water as the extraction solvent, and the acetone contained in the solution also acted as dispersive solvent. Under the optimum conditions, the linearity of the method was in the range 2-500 ng/g with correlation coefficients (r) of 0.9993-0.9999. The limits of detection were in the range of 0.08-0.56 ng/g. The relative standard deviations varied from 2.16 to 6.26% (n = 5). The enrichment factors ranged from 104 to 118. The extraction recoveries ranged from 81.05 to 97.82% for all of the analytes. The good performance has demonstrated that the proposed methodology has a strong potential for application in the multiresidue analysis of complex matrices. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Ionic-liquid-mediated poly(dimethylsiloxane)- grafted carbon nanotube fiber prepared by the sol-gel technique for the head space solid-phase microextraction of methyl tert-butyl ether using GC.

    PubMed

    Vatani, Hossein; Yazdi, Ali Sarafraz

    2014-01-01

    A headspace solid-phase microextraction method was developed for the preconcentration and extraction of methyl tert-butyl ether. An ionic-liquid-mediated multiwalled carbon nanotube-poly(dimethylsiloxane) hybrid coating, which was prepared by covalent functionalization of multiwalled carbon nanotubes with hydroxyl-terminated poly(dimethylsiloxane) using the sol-gel technique, was used as solid-phase microextraction adsorbent. This innovative fiber exhibited a highly porous surface structure, high thermal stability (at least 320°C) and long lifespan (over 210 uses). Potential factors affecting the extraction efficiency were optimized. Under the optimum conditions, the method LOD (S/N = 3) was 0.007 ng/mL and the LOQ (S/N = 10) was 0.03 ng/mL. The calibration curve was linear in the range of 0.03-200 ng/mL. The RSDs for one fiber (repeatability, n = 5) at three different concentrations (0.05, 1, and 150 ng/mL) were 5.1, 4.2, and 4.6% and for the fibers obtained from different batches (reproducibility, n = 3) were 6.5, 5.9, and 6.3%, respectively. The developed method was successfully applied to the determination of methyl tert-butyl ether in different real water samples on three consecutive days. The relative recoveries for the spiked samples with 0.05, 1, and 150 ng/mL were between 94-104%. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Rapid in situ growth of oriented titanium-nickel oxide composite nanotubes arrays coated on a nitinol wire as a solid-phase microextraction fiber coupled to HPLC-UV.

    PubMed

    Zhen, Qi; Zhang, Min; Song, Wenlan; Wang, Huiju; Wang, Xuemei; Du, Xinzhen

    2016-10-01

    An oriented titanium-nickel oxide composite nanotubes coating was in situ grown on a nitinol wire by direct electrochemical anodization in ethylene glycol with ammonium fluoride and water for the first time. The morphology and composition of the resulting coating showed that the anodized nitinol wire provided a titania-rich coating. The titanium-nickel oxide composite nanotubes coated fiber was used for solid-phase microextraction of different aromatic compounds coupled to high-performance liquid chromatography with UV detection. The titanium-nickel oxide composite nanotubes coating exhibited high extraction capability, good selectivity, and rapid mass transfer for weakly polar UV filters. Thereafter the important parameters affecting extraction efficiency were investigated for solid-phase microextraction of UV filters. Under the optimized conditions, the calibration curves were linear in the range of 0.1-300 μg/L for target UV filters with limits of detection of 0.019-0.082 μg/L. The intraday and interday precision of the proposed method with the single fiber were 5.3-7.2 and 5.9-7.9%, respectively, and the fiber-to-fiber reproducibility ranged from 6.3 to 8.9% for four fibers fabricated in different batches. Finally, its applicability was evaluated by the extraction and determination of target UV filters in environmental water samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Preparation and application of carbon nanotubes/poly(o-toluidine) composite fibers for the headspace solid-phase microextraction of benzene, toluene, ethylbenzene, and xylenes.

    PubMed

    Behzadi, Mansoureh; Noroozian, Ebrahim; Mirzaei, Mohammad

    2013-11-01

    A novel nanocomposite coating of poly(o-toluidine) and oxidized multiwalled CNTs (MWCNTs, where CNTs is carbon nanotubes) was electrochemically prepared on a stainless-steel wire. The applicability of the fiber was assessed for the headspace solid-phase microextraction of benzene, toluene, ethylbenzene, and xylenes in aqueous samples followed by GC with flame ionization detection. In order to obtain an adherent and stable composite coating, several experimental parameters related to the coating process, such as polymerization potential and time, and the concentration of o-toluidine and oxidized MWCNTs were optimized. The combination of MWCNTs and polymer in a nanocomposite form presents desirable opportunities to produce materials for new applications. The effects of various parameters on the efficiency of the headspace solid-phase microextraction process, such as desorption temperature and time, extraction temperature and time, and ionic strength were also investigated. At the optimum conditions, LODs were 0.03-0.06 μg/L. The method showed linearity in the range of 0.5-300 μg/L with coefficients of determination >0.99. The intraday and interday RSDs obtained at a 5 μg/L concentration level (n = 5) using a single fiber were 1.2-5.2 and 3.2-7.5%, respectively. The fiber-to-fiber RSD (%; n = 3) at 5 μg/L was 6.1-9.2%. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Determining octanol-water partition coefficients for extremely hydrophobic chemicals by combining "slow stirring" and solid-phase microextraction.

    PubMed

    Jonker, Michiel T O

    2016-06-01

    Octanol-water partition coefficients (KOW ) are widely used in fate and effects modeling of chemicals. Still, high-quality experimental KOW data are scarce, in particular for very hydrophobic chemicals. This hampers reliable assessments of several fate and effect parameters and the development and validation of new models. One reason for the limited availability of experimental values may relate to the challenging nature of KOW measurements. In the present study, KOW values for 13 polycyclic aromatic hydrocarbons were determined with the gold standard "slow-stirring" method (log KOW 4.6-7.2). These values were then used as reference data for the development of an alternative method for measuring KOW . This approach combined slow stirring and equilibrium sampling of the extremely low aqueous concentrations with polydimethylsiloxane-coated solid-phase microextraction fibers, applying experimentally determined fiber-water partition coefficients. It resulted in KOW values matching the slow-stirring data very well. Therefore, the method was subsequently applied to a series of 17 moderately to extremely hydrophobic petrochemical compounds. The obtained KOW values spanned almost 6 orders of magnitude, with the highest value measuring 10(10.6) . The present study demonstrates that the hydrophobicity domain within which experimental KOW measurements are possible can be extended with the help of solid-phase microextraction and that experimentally determined KOW values can exceed the proposed upper limit of 10(9) . Environ Toxicol Chem 2016;35:1371-1377. © 2015 SETAC. © 2015 SETAC.

  7. Automated headspace solid-phase dynamic extraction to analyse the volatile fraction of food matrices.

    PubMed

    Bicchi, Carlo; Cordero, Chiara; Liberto, Erica; Rubiolo, Patrizia; Sgorbini, Barbara

    2004-01-23

    High concentration capacity headspace techniques (headspace solid-phase microextraction (HS-SPME) and headspace sorptive extraction (HSSE)) are a bridge between static and dynamic headspace, since they give high concentration factors as does dynamic headspace (D-HS), and are as easy to apply and as reproducible as static headspace (S-HS). In 2000, Chromtech (Idstein, Germany) introduced an inside-needle technique for vapour and liquid sampling, solid-phase dynamic extraction (SPDE), also known as "the magic needle". In SPDE, analytes are concentrated on a 50 microm film of polydimethylsiloxane (PDMS) and activated carbon (10%) coated onto the inside wall of the stainless steel needle (5 cm) of a 2.5 ml gas tight syringe. When SPDE is used for headspace sampling (HS-SPDE), a fixed volume of the headspace of the sample under investigation is sucked up an appropriate number of times with the gas tight syringe and an analyte amount suitable for a reliable GC or GC-MS analysis accumulates in the polymer coating the needle wall. This article describes the preliminary results of both a study on the optimisation of sampling parameters conditioning HS-SPDE recovery, through the analysis of a standard mixture of highly volatile compounds (beta-pinene, isoamyl acetate and linalool) and of the HS-SPDE-GC-MS analyses of aromatic plants and food matrices. This study shows that HS-SPDE is a successful technique for HS-sampling with high concentration capability, good repeatability and intermediate precision, also when it is compared to HS-SPME.

  8. Determination of endocrine-disrupting compounds in water samples by magnetic nanoparticle-assisted dispersive liquid-liquid microextraction combined with gas chromatography-tandem mass spectrometry.

    PubMed

    Pérez, Rosa Ana; Albero, Beatriz; Tadeo, José Luis; Sánchez-Brunete, Consuelo

    2016-11-01

    A rapid extraction procedure is presented for the determination of five endocrine-disrupting compounds, estrone, ethinylestradiol, bisphenol A, triclosan, and 2-ethylhexylsalicylate, in water samples. The analysis involves a two-step extraction procedure that combines dispersive liquid-liquid microextraction (DLLME) with dispersive micro-solid phase extraction (D-μ-SPE), using magnetic nanoparticles, followed by in situ derivatization in the injection port of a gas chromatograph coupled to triple quadrupole mass spectrometry. The use of uncoated or oleate-coated Fe 3 O 4 nanoparticles as sorbent in the extraction process was evaluated and compared. The main parameters involved in the extraction process were optimized applying experimental designs. Uncoated Fe 3 O 4 nanoparticles were selected in order to simplify and make more cost-effective the procedure. DLLME was carried out at pH 3, during 2 min, followed by the addition of the nanoparticles for D-μ-SPE employing 1 min in the extraction. Analysis of spiked water samples of different sources gave satisfactory recovery results for all the compounds with detection limits ranging from 7 to 180 ng l -1 . Finally, the procedure was applied in tap, well, and river water. Graphical abstract Diagram of the extraction method using magnetic nanoparticles (MNPs).

  9. Conifer-Derived Monoterpenes and Forest Walking

    PubMed Central

    Sumitomo, Kazuhiro; Akutsu, Hiroaki; Fukuyama, Syusei; Minoshima, Akiho; Kukita, Shin; Yamamura, Yuji; Sato, Yoshiaki; Hayasaka, Taiki; Osanai, Shinobu; Funakoshi, Hiroshi; Hasebe, Naoyuki; Nakamura, Masao

    2015-01-01

    Conifer and broadleaf trees emit volatile organic compounds in the summer. The major components of these emissions are volatile monoterpenes. Using solid phase microextraction fiber as the adsorbant, monoterpenes were successfully detected and identified in forest air samples. Gas chromatography/mass chromatogram of monoterpenes in the atmosphere of a conifer forest and that of serum from subjects who were walking in a forest were found to be similar each other. The amounts of α-pinene in the subjects became several folds higher after forest walking. The results indicate that monoterpenes in the atmosphere of conifer forests are transferred to and accumulate in subjects by inhalation while they are exposed to this type of environment. PMID:26819913

  10. Soy sauce classification by geographic region and fermentation based on artificial neural network and genetic algorithm.

    PubMed

    Xu, Libin; Li, Yang; Xu, Ning; Hu, Yong; Wang, Chao; He, Jianjun; Cao, Yueze; Chen, Shigui; Li, Dongsheng

    2014-12-24

    This work demonstrated the possibility of using artificial neural networks to classify soy sauce from China. The aroma profiles of different soy sauce samples were differentiated using headspace solid-phase microextraction. The soy sauce samples were analyzed by gas chromatography-mass spectrometry, and 22 and 15 volatile aroma compounds were selected for sensitivity analysis to classify the samples by fermentation and geographic region, respectively. The 15 selected samples can be classified by fermentation and geographic region with a prediction success rate of 100%. Furans and phenols represented the variables with the greatest contribution in classifying soy sauce samples by fermentation and geographic region, respectively.

  11. A new chemical tool for absinthe producers, quantification of α/β-thujone and the bitter components in Artemisia absinthium.

    PubMed

    Bach, Benoit; Cleroux, Marilyn; Saillen, Mayra; Schönenberger, Patrik; Burgos, Stephane; Ducruet, Julien; Vallat, Armelle

    2016-12-15

    The concentrations of α/β-thujone and the bitter components of Artemisia absinthium were quantified from alcoholic wormwood extracts during four phenological stages of their harvest period. A solid-phase micro-extraction method coupled to gas chromatography-mass spectrometry was used to determine the concentration of the two isomeric forms of thujone. In parallel, the combination of ultra-high pressure liquid chromatography and high resolution mass spectrometry allowed to quantify the compounds absinthin, artemisetin and dihydro-epi-deoxyarteannuin B. This present study aimed at helping absinthe producers to determine the best harvesting period. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Characterization of the aroma profile of novel Brazilian wines by solid-phase microextraction using polymeric ionic liquid sorbent coatings.

    PubMed

    Crucello, Juliana; Miron, Luiz F O; Ferreira, Victor H C; Nan, He; Marques, Marcia O M; Ritschel, Patricia S; Zanus, Mauro C; Anderson, Jared L; Poppi, Ronei J; Hantao, Leandro W

    2018-05-28

    In this study, a series of polymeric ionic liquid (PIL) sorbent coatings is evaluated for the extraction of polar volatile organic compounds (VOCs) from Brazilian wines using headspace solid-phase microextraction (HS-SPME), including samples from 'Isabella' and 'BRS Magna' cultivars-the latter was recently introduced by the Brazilian Agricultural Research Corporation - National Grape & Wine Research Center. The structurally tuned SPME coatings were compared to the commercial SPME phases, namely poly(acrylate) (PA) and divinylbenzene/carboxen/poly(dimethylsiloxane) (DVB/CAR/PDMS). The separation, detection and identification of the aroma profiles were obtained using comprehensive two-dimensional gas chromatography mass spectrometry (GC×GC-MS). The best performing PIL-based SPME fiber, namely 1-hexadecyl-3-vinylimidazolium bis[(trifluoromethyl)sulfonyl]imide with 1,12-di(3-vinylimidazolium)dodecane dibis[(trifluoromethyl)sulfonyl]imide incorporated cross-linker supported on an elastic nitinol wire, exhibited superior performance to DVB/CAR/PDMS regarding the average number of extracted peaks and extracted more polar analytes providing additional insight into the aroma profile of 'BRS Magna' wines. Four batches of wine were evaluated, namely 'Isabella' and 'BRS Magna' vintages 2015 and 2016, using highly selective PIL-based SPME coatings and enabled the detection of 350+ peaks. Furthermore, this is the first report evaluating the aroma of 'BRS Magna' wines. A hybrid approach that combined pixel-based Fisher ratio and peak table-based data comparison was used for data handling. This proof-of-concept experiment provided reliable and statistically valid distinction of wines that may guide regulation agencies to create high sample throughput protocols to screen wines exported by Brazilian vintners. Graphical abstract Highly selective extraction of wine aroma using polymeric ionic liquid.

  13. Analysis of Mars analogue soil samples using solid-phase microextraction, organic solvent extraction and gas chromatography/mass spectrometry

    NASA Astrophysics Data System (ADS)

    Orzechowska, G. E.; Kidd, R. D.; Foing, B. H.; Kanik, I.; Stoker, C.; Ehrenfreund, P.

    2011-07-01

    Polycyclic aromatic hydrocarbons (PAHs) are robust and abundant molecules in extraterrestrial environments. They are found ubiquitously in the interstellar medium and have been identified in extracts of meteorites collected on Earth. PAHs are important target molecules for planetary exploration missions that investigate the organic inventory of planets, moons and small bodies. This study is part of an interdisciplinary preparation phase to search for organic molecules and life on Mars. We have investigated PAH compounds in desert soils to determine their composition, distribution and stability. Soil samples (Mars analogue soils) were collected at desert areas of Utah in the vicinity of the Mars Desert Research Station (MDRS), in the Arequipa region in Peru and from the Jutland region of Denmark. The aim of this study was to optimize the solid-phase microextraction (SPME) method for fast screening and determination of PAHs in soil samples. This method minimizes sample handling and preserves the chemical integrity of the sample. Complementary liquid extraction was used to obtain information on five- and six-ring PAH compounds. The measured concentrations of PAHs are, in general, very low, ranging from 1 to 60 ng g-1. The texture of soils is mostly sandy loam with few samples being 100 % silt. Collected soils are moderately basic with pH values of 8-9 except for the Salten Skov soil, which is slightly acidic. Although the diverse and variable microbial populations of the samples at the sample sites might have affected the levels and variety of PAHs detected, SPME appears to be a rapid, viable field sampling technique with implications for use on planetary missions.

  14. Analysis of Mars Analogue Soil Samples Using Solid-Phase Microextraction, Organic Solvent Extraction and Gas Chromatography/Mass Spectrometry

    NASA Technical Reports Server (NTRS)

    Orzechowska, G. E.; Kidd, R. D.; Foing, B. H.; Kanik, I.; Stoker, C.; Ehrenfreund, P.

    2011-01-01

    Polycyclic aromatic hydrocarbons (PAHs) are robust and abundant molecules in extraterrestrial environments. They are found ubiquitously in the interstellar medium and have been identified in extracts of meteorites collected on Earth. PAHs are important target molecules for planetary exploration missions that investigate the organic inventory of planets, moons and small bodies. This study is part of an interdisciplinary preparation phase to search for organic molecules and life on Mars. We have investigated PAH compounds in desert soils to determine their composition, distribution and stability. Soil samples (Mars analogue soils) were collected at desert areas of Utah in the vicinity of the Mars Desert Research Station (MDRS), in the Arequipa region in Peru and from the Jutland region of Denmark. The aim of this study was to optimize the solid-phase microextraction (SPME) method for fast screening and determination of PAHs in soil samples. This method minimizes sample handling and preserves the chemical integrity of the sample. Complementary liquid extraction was used to obtain information on five- and six-ring PAH compounds. The measured concentrations of PAHs are, in general, very low, ranging from 1 to 60 ng g(sup -1). The texture of soils is mostly sandy loam with few samples being 100% silt. Collected soils are moderately basic with pH values of 8-9 except for the Salten Skov soil, which is slightly acidic. Although the diverse and variable microbial populations of the samples at the sample sites might have affected the levels and variety of PAHs detected, SPME appears to be a rapid, viable field sampling technique with implications for use on planetary missions.

  15. PEEK tube-based online solid-phase microextraction-high-performance liquid chromatography for the determination of yohimbine in rat plasma and its application in pharmacokinetics study.

    PubMed

    Xiang, Xiaowei; Shang, Bing; Wang, Xiaozheng; Chen, Qinhua

    2017-04-01

    Yohimbine is a novel compound for the treatment of erectile dysfunction derived from natural products, and pharmacokinetic study is important for its further development as a new medicine. In this work, we developed a novel PEEK tube-based solid-phase microextraction (SPME)-HPLC method for analysis of yohimbine in plasma and further for pharmacokinetic study. Poly (AA-EGDMA) was synthesized inside a PEEK tube as the sorbent for microextraction of yohimbine, and parameters that could influence extraction efficiency were systematically investigated. Under optimum conditions, the PEEK tube-based SPME method exhibits excellent enrichment efficiency towards yohimbine. By using berberine as internal standard, an online SPME-HPLC method was developed for analysis of yohimbine in human plasma sample. The method has wide linear range (2-1000 ng/mL) with an R 2 of 0.9962; the limit of detection was determined and was as low as 0.1 ng/mL using UV detection. Finally, a pharmacokinetic study of yohimbine was carried out by the online SPME-HPLC method and the results have been compared with those of reported methods. Copyright © 2016 John Wiley & Sons, Ltd.

  16. Solid-phase microextraction and chiral HPLC analysis of ibuprofen in urine.

    PubMed

    de Oliveira, Anderson Rodrigo Moraes; Cesarino, Evandro José; Bonato, Pierina Sueli

    2005-04-25

    A simple and rapid solid-phase microextraction method was developed for the enantioselective analysis of ibuprofen in urine. The sampling was made with a polydimethylsiloxane-divinylbenzene coated fiber immersed in the liquid sample. After desorptioning from the fiber, ibuprofen enantiomers were analyzed by HPLC using a Chiralpak AD-RH column and UV detection. The mobile phase was made of methanol-pH 3.0 phosphoric acid solution (75:25, v/v), at a flow rate of 0.45 mL/min. The mean recoveries of SPME were 19.8 and 19.1% for (-)-R-ibuprofen and (+)-(S)-ibuprofen, respectively. The method was linear at the range of 0.25-25 microg/mL. Within-day and between-day assay precision and accuracy were below 15% for both ibuprofen enantiomers at concentrations of 0.75, 7.5 and 20 microg/mL. The method was tested with urine quality control samples and human urine fractions after administration of 200 mg rac-ibuprofen.

  17. Determination of free and deconjugated testosterone and epitestosterone in urine using SPME and LC-MS/MS.

    PubMed

    Zhan, Yanwei; Musteata, Florin M; Basset, Fabien A; Pawliszyn, Janusz

    2011-01-01

    A thin sheet of polydimethylsilosane membrane was used as an extraction phase for solid-phase microextraction. Compared with fiber or rod solid-phase microextraction geometries, the thin film exhibited much higher extraction capacity without sacrificing extraction time due to its higher area-to-volume ratio. The analytical method involved direct extraction of unconjugated testosterone (T) and epitestosterone (ET) followed by separation on a C18 column and detection by selected reaction monitoring in positive ionization mode. The limit of detection was 1 ng/l for both T and ET. After method validation, free (unconjugated) T and ET were extracted and quantified in real samples. Since T and ET are extensively metabolized, the proposed method was also applied to extract the steroids after enzymatic deconjugation of urinary-excreted steroid glucuronides. The proposed method allows quantification of both conjugated and unconjugated steroids, and revealed that there was a change in the ratio of T to ET after enzymatic deconjugation, indicating different rates of metabolism.

  18. Optimization of headspace solid phase micro-extraction of volatile compounds from papaya fruit assisted by GC-olfactometry.

    PubMed

    da Rocha, Renier Felinto Julião; da Silva Araújo, Ídila Maria; de Freitas, Sílvia Maria; Dos Santos Garruti, Deborah

    2017-11-01

    Optimization of the extraction conditions to investigate the volatile composition of papaya fruit involving headspace solid phase micro-extraction was carried out using multivariate strategies such as factorial design and response surface methodology. The performance of different combinations of time for reaching the equilibrium in the headspace and time for maximum extraction of volatiles was evaluated by GC-olfactometry of the extract (intensity of papaya characteristic aroma), number of peaks and total area in the chromatogram. Thirty-two compounds were identified by GC-MS under the optimized extraction conditions, the majority of which were aldehydes, both in number of compounds and area. Major compounds were δ-octalactone, β-citral, benzaldehyde, heptanal, benzyl isothiocyanate, isoamyl acetate, γ-octalactone, (E)-linalool oxide and benzyl alcohol. Seven aldehydes and two other compounds are reported for the first time in papaya's volatile profile.

  19. Solid-phase microextraction of benzimidazole fungicides in environmental liquid samples and HPLC-fluorescence determination.

    PubMed

    López Monzón, A; Vega Moreno, D; Torres Padrón, M E; Sosa Ferrera, Z; Santana Rodríguez, J J

    2007-03-01

    Solid-phase microextraction (SPME) coupled with high-performance liquid chromatography (HPLC) with fluorescence detection was optimized for extraction and determination of four benzimidazole fungicides (benomyl, carbendazim, thiabendazole, and fuberidazole) in water. We studied extraction and desorption conditions, for example fiber type, extraction time, ionic strength, extraction temperature, and desorption time to achieve the maximum efficiency in the extraction. Results indicate that SPME using a Carboxen-polydimethylsiloxane 75 microm (CAR-PDMS) fiber is suitable for extraction of these types of compound. Final analysis of benzimidazole fungicides was performed by HPLC with fluorescence detection. Recoveries ranged from 80.6 to 119.6 with RSDs below 9% and limits of detection between 0.03 and 1.30 ng mL-1 for the different analytes. The optimized procedure was applied successfully to the determination of benzimidazole fungicides mixtures in environmental water samples (sea, sewage, and ground water).

  20. Solid-phase microextraction coupled with high-performance liquid chromatography for the determination of phenylurea herbicides in aqueous samples.

    PubMed

    Lin, Hsin-Hang; Sung, Yu-Hsiang; Huang, Shang-Da

    2003-09-12

    Solid-phase microextraction coupled with high-performance liquid chromatography was successfully applied to the analysis of nine phenylurea herbicides (metoxuron, monuron, chlorotoluron, isoproturon, monolinuron, metobromuron, buturon, linuron, and chlorbromuron). Polydimethylsiloxane-divinylbenzene (PDMS-DVB, 60 microm) and Carbowax-templated resin (CW-TPR, 50 microm) fibers were selected from four commercial fibers for further study because of their better extraction efficiencies. The parameters of the desorption procedure were studied and optimized. The effects of the properties of analytes and fiber coatings, carryover, duration and temperature of absorption, pH, organic solvent and ionic strength of samples were also investigated. External calibration with an aqueous standard can be used for the analysis of environmental samples (lake water) using either PDMS-DVB or CW-TPR fibers. Good precisions (1.0-5.9%) are achieved for this method, and the detection limits are at the level of 0.5-5.1 ng/ml.

  1. Coupling solid-phase microextraction and high-performance liquid chromatography for direct and sensitive determination of halogenated fungicides in wine.

    PubMed

    Millán, S; Sampedro, M C; Unceta, N; Goicolea, M A; Rodríguez, E; Barrio, R J

    2003-05-02

    A solid-phase microextraction (SPME) method coupled to high-performance liquid chromatography with diode array detection (HPLC-DAD) for the analysis of six organochlorine fungicides (nuarimol, triadimenol, triadimefon, folpet, vinclozolin and penconazole) in wine was developed. For this purpose, polydimethylsiloxane-divinylbenzene-coated fibers were utilized and all factors affecting throughput, precision, and accuracy of the SPME method were investigated and optimized. These factors include: matrix influence, extraction and desorption time, percentage of ethanol, pH, salt effect and desorption mode. The performed analytical procedure showed detectability ranging from 4 to 27 microg l(-1) and precision from 2.4 to 14.2% (as intra-day relative standard deviation, RSD) and 4.7-25.7% (as inter-day RSD) depending on the fungicide. The results demonstrate the suitability of the SPME-HPLC-DAD method to analyze these organochlorine fungicides in red wine.

  2. Carboxylated multiwalled carbon nanotubes/polydimethylsiloxane, a new coating for 96-blade solid-phase microextraction for determination of phenolic compounds in water.

    PubMed

    Kueseng, Pamornrat; Pawliszyn, Janusz

    2013-11-22

    A new thin-film, carboxylated multiwalled carbon nanotubes/polydimethylsiloxane (MWCNTs-COOH/PDMS) coating was developed for 96-blade solid-phase microextraction (SPME) system followed by high performance liquid chromatography with ultraviolet detection (HPLC-UV). The method provided good extraction efficiency (64-90%) for three spiked levels, with relative standard deviations (RSD)≤6%, and detection limits between 1 and 2 μg/L for three phenolic compounds. The MWCNTs-COOH/PDMS 96-blade SPME system presents advantages over traditional methods due to its simplicity of use, easy coating preparation, low cost and high sample throughput (2.1 min per sample). The developed coating is reusable for a minimum of 110 extractions with good extraction efficiency. The coating provided higher extraction efficiency (3-8 times greater) than pure PDMS coatings. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Portable Solid Phase Micro-Extraction Coupled with Ion Mobility Spectrometry System for On-Site Analysis of Chemical Warfare Agents and Simulants in Water Samples

    PubMed Central

    Yang, Liu; Han, Qiang; Cao, Shuya; Yang, Jie; Yang, Junchao; Ding, Mingyu

    2014-01-01

    On-site analysis is an efficient approach to facilitate analysis at the location of the system under investigation as it can result in more accurate, more precise and quickly available analytical data. In our work, a novel self-made thermal desorption based interface was fabricated to couple solid-phase microextraction with ion mobility spectrometry for on-site water analysis. The portable interface can be connected with the front-end of an ion mobility spectrometer directly without other modifications. The analytical performance was evaluated via the extraction of chemical warfare agents and simulants in water samples. Several parameters including ionic strength and extraction time have been investigated in detail. The application of the developed method afforded satisfactory recoveries ranging from 72.9% to 114.4% when applied to the analysis of real water samples. PMID:25384006

  4. Quantitation of (R)- and (S)-linalool in beer using solid phase microextraction (SPME) in combination with a stable isotope dilution assay (SIDA).

    PubMed

    Steinhaus, Martin; Fritsch, Helge T; Schieberle, Peter

    2003-11-19

    A stable isotope dilution assay (SIDA) was developed for the quantitation of both linalool enantiomers using synthesized [2H(2)]R/S-linalool as the internal standard. For enrichment of the target compound from beer, a solid phase microextraction method (SPME) was developed. In comparison to the more time-consuming extraction/distillation cleanup of the beer samples, the results obtained by SPME/SIDA were very similar, even under nonequilibration conditions. Analysis of five different types of beer showed significant differences in the linalool concentrations, which were clearly correlated with the intensity of the hoppy aroma note as evaluated by a sensory panel. In addition, significant differences in the R/S ratios were measured in the beers. The SPME/SIDA yielded exact data independently from headspace sampling parameters, such as exposure time or ionic strength of the solution.

  5. Role of solid-phase microextraction in the identification of highly volatile pheromones of two Rhinoceros beetles Scapanes australis and Strategus aloeus (Coleoptera, Scarabaeidae, Dynastinae).

    PubMed

    Rochat, D; Ramirez-Lucas, P; Malosse, C; Aldana, R; Kakul, T; Morin, J P

    2000-07-14

    Solid-phase microextraction (SPME) samplings from live insects or natural secretion allowed one to identify the aggregation pheromones of the pest beetles Scapanes australis and Strategus aloeus by efficient and rapid isolation of their highly volatile (72 < M(r) < 116) components. S. australis male pheromone was identified as a 84:12:4 (w/w) mixture of 2-butanol [67:33 (R)-(-):(S)-(+) ratio], 3-hydroxy-2-butanone and 2,3-butanediol [43:17:40 (R,R)-(-):(S,S)-(+):meso ratio], and S. aloeus pheromone as a 95.5:4.0:0.5 (w/w) mixture of 2-butanone, 3-pentanone and sec.-butyl acetate by GC-MS using conventional and chiral capillary columns. This is the first report of Scarabaeidae pheromones based on such small and common molecules.

  6. Silk fiber for in-tube solid-phase microextraction to detect aldehydes by chemical derivatization.

    PubMed

    Wang, Xiuqin; Pan, Lei; Feng, Juanjuan; Tian, Yu; Luo, Chuannan; Sun, Min

    2017-11-03

    Aldehydes are the potentially damaging pollutants in the environment, but it is difficult to be determined due to the low concentration level. Therefore, to accurate analysis of aldehydes, it is important for efficient sample preparation with selective enrichment and rapid separation. Environmentally friendly silk fiber as adsorbent material was directly applied to develop in-tube solid-phase microextraction for analyzing aqueous samples combined with high performance liquid chromatography. 2,4-Dinitrophenylhydrazine as a derivative reagent was used for chemical derivatization of aldehydes before extraction. Under optimum conditions, an online analysis method was built with the limits of detection in the range of 0.005-0.01μgL -1 and the linearity in the range of 0.03-10μgL -1 . Three aldehydes were determined in two real samples, and the relative recoveries were in the range of 95-102%. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. A new supramolecular based liquid solid microextraction method for preconcentration and determination of trace bismuth in human blood serum and hair samples by electrothermal atomic absorption spectrometry.

    PubMed

    Kahe, Hadi; Chamsaz, Mahmoud

    2016-11-01

    A simple and reliable supramolecule-aggregated liquid solid microextraction method is described for preconcentration and determination of trace amounts of bismuth in water as well as human blood serum and hair samples. Catanionic microstructures of cetyltrimethylammonium bromide (CTAB) and sodium dodecyl sulfate (SDS) surfactants, dissolved in deionized water/propanol, are used as a green solvent to extract bismuth (III)-diethyldithiocarbamate complexes by dispersive microextraction methodology. The extracted solid phase is easily removed and dissolved in 50 μL propanol for subsequent measurement by electrothermal atomic absorption spectrometry (ET-AAS). The procedure benefits the merits of supramolecule aggregates' properties and dispersive microextraction technique using water as the main component of disperser solvent, leading to direct interaction with analyte. Phase separation behavior of extraction solvent and different parameters influencing the extraction efficiency of bismuth ion such as salt concentration, pH, centrifugation time, amount of chelating agent, SDS:CTAB mole ratio, and solvent amounts were thoroughly optimized. Under the optimal experimental conditions, the calibration curve was linear in the range of 0.3-6 μg L -1 Bi (III) with a limit of detection (LOD) of 0.16 μg L -1 (S/N = 3). The relative standard deviations (RSD) of determination were obtained to be 5.1 and 6.2 % for 1 and 3 μg L -1 of Bi (III), respectively. The developed method was successfully applied as a sensitive and accurate technique for determination of bismuth ion in human blood serum, hair samples, and a certified reference material.

  8. Novel micro-extraction by packed sorbent procedure for the liquid chromatographic analysis of antiepileptic drugs in human plasma and urine.

    PubMed

    Rani, Susheela; Malik, Ashok K; Singh, Baldev

    2012-02-01

    A method for the simultaneous determination of the antiepileptic drugs, phenobarbital (PHB), phenytoin (PTN), carbamazepine (CBZ), primidone (PRM) and oxcarbazepine (OXC) in human plasma and urine samples by using micro-extraction in a packed syringe as the sample preparation method connected with LC/UV (MEPS/LC/UV) is described. Micro-extraction in a packed syringe (MEPS) is a new miniaturized, solid-phase extraction technique that can be connected online to gas or liquid chromatography without any modifications. In MEPS approximately 1 mg of the solid packing material is inserted into a syringe (100-250 μL) as a plug. Sample preparation takes place on the packed bed. The bed can be coated to provide selective and suitable sampling conditions. The new method is very promising, easy to use, fully automated, inexpensive and quick. The standard curves were obtained within the concentration range 1-500 ng/mL in both plasma and urine samples. The results showed high correlation coefficients (R(2) >0.988) for all of the analytes within the calibration range. The extraction recovery was found to be between 88.56 and 99.38%. The limit of quantification was found to be between 0.132 and 1.956 ng/mL. The precision (RSD) values of quality control samples (QC) had a maximum deviation of 4.9%. A comparison of the detection limits with similar methods indicates high sensitivity of the present method. The method is applied for the analysis of these drugs in real urine and plasma samples of epileptic patients. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Characterization of traditional Istrian dry-cured ham by means of physical and chemical analyses and volatile compounds.

    PubMed

    Marušić, Nives; Petrović, Marinko; Vidaček, Sanja; Petrak, Tomislav; Medić, Helga

    2011-08-01

    The aroma-active compounds of Istrian dry-cured ham were investigated by using headspace-solid phase microextraction and gas chromatography-mass spectrometry (GC-MS). Samples of biceps femoris were also evaluated by measuring physical and chemical characteristics: moisture, protein, fat, ash and NaCl content, a(w) value; colour: L*, a*, b* and oxidation of fat: TBARS test. About 50 volatile compounds were identified and quantified which belonged to several classes of chemical: 5 alcohols, 8 aldehydes, 7 alkanes, 1 ketone, 2 esters, 9 monoterpenes and 15 sesquiterpenes. Except volatile compounds derived from lipolysis and proteolysis the most abundant constituents were terpenes (62.97; 41.43%) that originate from spices added in the salting phase of the production process. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Combination of magnetic dispersive micro solid-phase extraction and supramolecular solvent-based microextraction followed by high-performance liquid chromatography for determination of trace amounts of cholesterol-lowering drugs in complicated matrices.

    PubMed

    Arghavani-Beydokhti, Somayeh; Rajabi, Maryam; Asghari, Alireza

    2017-07-01

    A novel, efficient, rapid, simple, sensitive, selective, and environmentally friendly method termed magnetic dispersive micro solid-phase extraction combined with supramolecular solvent-based microextraction (Mdμ-SPE-SSME) followed by high-performance liquid chromatography (HPLC) with UV detection is introduced for the simultaneous microextraction of cholesterol-lowering drugs in complicated matrices. In the first microextraction procedure, using layered double hydroxide (LDH)-coated Fe 3 O 4 magnetic nanoparticles, an efficient sample cleanup is simply and rapidly provided without the need for time-consuming centrifugation and elution steps. In the first step, desorption of the target analytes is easily performed through dissolution of the LDH-coated magnetic nanoparticles containing the target analytes in an acidic solution. In the next step, an emulsification microextraction method based on a supramolecular solvent is used for excellent preconcentration, ultimately resulting in an appropriate determination of the target analytes in real samples. Under the optimal experimental conditions, the Mdμ-SPE-SSME-HPLC-UV detection procedure provides good linearity in the ranges of 1.0-1500 ng mL -1 , 1.5-2000 ng mL -1 , and 2.0-2000 ng mL -1 with coefficients of determination of 0.995 or less, low limits of detection (0.3, 0.5, and 0.5 ng mL -1 ), and good extraction repeatabilities (relative standard deviations below 7.8%, n = 5) in deionized water for rosuvastatin, atorvastatin, and gemfibrozil, respectively. Finally, the proposed method is successfully applied for the determination of the target analytes in complicated matrices. Graphical Abstract Mdμ-SPE-SSME procedure.

  11. Short communication: low-fat ice cream flavor not modified by high hydrostatic pressure treatment of whey protein concentrate.

    PubMed

    Chauhan, J M; Lim, S-Y; Powers, J R; Ross, C F; Clark, S

    2010-04-01

    The purpose of this study was to examine flavor binding of high hydrostatic pressure (HHP)-treated whey protein concentrate (WPC) in a real food system. Fresh Washington State University (WSU, Pullman) WPC, produced by ultrafiltration of separated Cheddar cheese whey, was treated at 300 MPa for 15 min. Commercial WPC 35 powder was reconstituted to equivalent total solids as WSU WPC (8.23%). Six batches of low-fat ice cream were produced: A) HHP-treated WSU WPC without diacetyl; B) and E) WSU WPC with 2 mg/L of diacetyl added before HHP; C) WSU WPC with 2 mg/L of diacetyl added after HHP; D) untreated WSU WPC with 2 mg/L of diacetyl; and F) untreated commercial WPC 35 with 2 mg/L of diacetyl. The solution of WSU WPC or commercial WPC 35 contributed 10% to the mix formulation. Ice creams were produced by using standard ice cream ingredients and processes. Low-fat ice creams containing HHP-treated WSU WPC and untreated WSU WPC were analyzed using headspace-solid phase microextraction-gas chromatography. Sensory evaluation by balanced reference duo-trio test was carried out using 50 untrained panelists in 2 sessions on 2 different days. The headspace-solid phase microextraction-gas chromatography analysis revealed that ice cream containing HHP-treated WSU WPC had almost 3 times the concentration of diacetyl compared with ice cream containing untreated WSU WPC at d 1 of storage. However, diacetyl was not detected in ice creams after 14 d of storage. Eighty percent of panelists were able to distinguish between low-fat ice creams containing untreated WSU WPC with and without diacetyl, confirming panelists' ability to detect diacetyl. However, panelists were not able to distinguish between low-fat ice creams containing untreated and HHP-treated WSU WPC with diacetyl. These results show that WPC diacetyl-binding properties were not enhanced by 300-MPa HHP treatment for 15 min, indicating that HHP may not be suitable for such applications. Copyright (c) 2010 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  12. Multiwall carbon nanotube- zirconium oxide nanocomposite hollow fiber solid phase microextraction for determination of polyaromatic hydrocarbons in water, coffee and tea samples.

    PubMed

    Yazdi, Mahnaz Nozohour; Yamini, Yadollah; Asiabi, Hamid

    2018-06-15

    The purpose of this study was to evaluate the application of hollow fiber solid-phase microextraction (HF-SPME) followed by HPLC-UV to determine the ultra-trace amounts of polycyclic aromatic hydrocarbons (PAHs) as model analytes in complex coffee and tea samples. HF-SPME can be effectively used as an alternative to the direct immersion SPME (DI-SPME) method in complex matrices. The DI-SPME method suffers from serious limitation in dirty and complicated matrices with low sample clean-up, while the HF-SPME method has high clean-up and selectivity due to the high porosity of hollow fiber that can pick out analyte from complicated matrices. As a hollow fiber sorbent, a novel multiwall carbon nanotube/zirconium oxide nanocomposite (MWCNT/ZrO 2 ) was fabricated. The excellent adsorption of PAHs on the sorbent was attributed to the dominant roles of π-π stacking interaction and hydrophobic interaction. Under the optimized extraction conditions, the wide linear range of 0.1-200 μg L -1 with coefficients of determination better than 0.998 and low detection limits of 0.033-0.16 μg L -1 with satisfactory precision (RSD < 6.6%) were obtained. The relative recoveries obtained by spiking the PAHs in water, coffee and tea samples were in the range of 92.0-106.0%. Compared to other methods, MWCNT/ZrO 2 hollow fiber solid phase microextraction demonstrated a good capability for determination of PAHs in complex coffee and tea samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Multiple monolithic fiber solid-phase microextraction based on a polymeric ionic liquid with high-performance liquid chromatography for the determination of steroid sex hormones in water and urine.

    PubMed

    Liao, Keren; Mei, Meng; Li, Haonan; Huang, Xiaojia; Wu, Cuiqin

    2016-02-01

    The development of a simple and sensitive analytical approach that combines multiple monolithic fiber solid-phase microextraction with liquid desorption followed by high-performance liquid chromatography with diode array detection is proposed for the determination of trace levels of seven steroid sex hormones (estriol, 17β-estradiol, testosterone, ethinylestradiol, estrone, progesterone and mestranol) in water and urine matrices. To extract the target analytes effectively, multiple monolithic fiber solid-phase microextraction based on a polymeric ionic liquid was used to concentrate hormones. Several key extraction parameters including desorption solvent, extraction and desorption time, pH value and ionic strength in sample matrix were investigated in detail. Under the optimal experimental conditions, the limits of detection were found to be in the range of 0.027-0.12 μg/L. The linear range was 0.10-200 μg/L for 17β-estradiol, 0.25-200 μg/L estriol, ethinylestradiol and estrone, and 0.50-200 μg/L for the other hormones. Satisfactory linearities were achieved for analytes with the correlation coefficients above 0.99. Acceptable method reproducibility was achieved by evaluating the repeatability and intermediate precision with relative standard deviations of both less than 8%. The enrichment factors ranged from 54- to 74-fold. Finally, the proposed method was successfully applied to the analysis of steroid sex hormones in environmental water samples and human urines with spiking recoveries ranged from 75.6 to 116%. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Optimization of multiwalled carbon nanotubes reinforced hollow-fiber solid-liquid-phase microextraction for the determination of polycyclic aromatic hydrocarbons in environmental water samples using experimental design.

    PubMed

    Hamedi, Raheleh; Hadjmohammadi, Mohammad Reza

    2017-09-01

    A novel design of hollow-fiber liquid-phase microextraction containing multiwalled carbon nanotubes as a solid sorbent, which is immobilized in the pore and lumen of hollow fiber by the sol-gel technique, was developed for the pre-concentration and determination of polycyclic aromatic hydrocarbons in environmental water samples. The proposed method utilized both solid- and liquid-phase microextraction media. Parameters that affect the extraction of polycyclic aromatic hydrocarbons were optimized in two successive steps as follows. Firstly, a methodology based on a quarter factorial design was used to choose the significant variables. Then, these significant factors were optimized utilizing central composite design. Under the optimized condition (extraction time = 25 min, amount of multiwalled carbon nanotubes = 78 mg, sample volume = 8 mL, and desorption time = 5 min), the calibration curves showed high linearity (R 2  = 0.99) in the range of 0.01-500 ng/mL and the limits of detection were in the range of 0.007-1.47 ng/mL. The obtained extraction recoveries for 10 ng/mL of polycyclic aromatic hydrocarbons standard solution were in the range of 85-92%. Replicating the experiment under these conditions five times gave relative standard deviations lower than 6%. Finally, the method was successfully applied for pre-concentration and determination of polycyclic aromatic hydrocarbons in environmental water samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Recent Application of Solid Phase Based Techniques for Extraction and Preconcentration of Cyanotoxins in Environmental Matrices.

    PubMed

    Mashile, Geaneth Pertunia; Nomngongo, Philiswa N

    2017-03-04

    Cyanotoxins are toxic and are found in eutrophic, municipal, and residential water supplies. For this reason, their occurrence in drinking water systems has become a global concern. Therefore, monitoring, control, risk assessment, and prevention of these contaminants in the environmental bodies are important subjects associated with public health. Thus, rapid, sensitive, selective, simple, and accurate analytical methods for the identification and determination of cyanotoxins are required. In this paper, the sampling methodologies and applications of solid phase-based sample preparation methods for the determination of cyanotoxins in environmental matrices are reviewed. The sample preparation techniques mainly include solid phase micro-extraction (SPME), solid phase extraction (SPE), and solid phase adsorption toxin tracking technology (SPATT). In addition, advantages and disadvantages and future prospects of these methods have been discussed.

  16. Determination of Aromatic Amines Using Solid-Phase Microextraction Based on an Ionic Liquid-Mediated Sol-Gel Technique.

    PubMed

    Abbasi, Vajihe; Sarafraz-Yazdi, Ali; Amiri, Amirhassan; Vatani, Hossein

    2016-04-01

    A headspace solid-phase microextraction (HS-SPME) method was developed for isolation of monocyclic aromatic amines from water samples followed by gas chromatography-flame ionization detector (GC-FID). In this work, the effect of the presence of ionic liquid (namely, 1-hexyl-3-methyl-imidazolium hexafluorophosphate [C6MIM][PF6]) was investigated in the sol-gel coating solutions on the morphology and extraction behavior of the resulting hybrid organic-inorganic sol-gel sorbents utilized in SPME. Hydroxy-terminated poly(dimethylsiloxane) (PDMS) was used as the sol-gel active organic component for sol-gel hybrid coatings. Two different coated fibers that were prepared are PDMS and PDMS-IL ([C6MIM][PF6]) fibers. Under the optimal conditions, the method detection limits (S/N = 3) with PDMS-IL were in the range of 0.001-0.1 ng/mL and the limits of quantification (S/N = 10) between 0.005 and 0.5 ng/mL. The relative standard deviations for one fiber (n = 5) were obtained from 3.1 up to 8.5% and between fibers or batch to batch (n = 3) in the range of 5.3-10.1%. The developed method was successfully applied to real water and juice fruits samples while the relative recovery percentages obtained for the spiked water samples at 0.1 ng/mL were from 83.3 to 95.0%. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Analysis of black pepper volatiles by solid phase microextraction-gas chromatography: A comparison of terpenes profiles with hydrodistillation.

    PubMed

    Jeleń, Henryk H; Gracka, Anna

    2015-10-30

    Solid phase microextraction (SPME) is widely used in food flavor compounds analysis in majority for profiling volatile compounds. Based on such profiles conclusions are often drawn concerning the percentage composition of volatile compounds in particular food, spices or raw materials. This paper focuses on the usefulness of SPME for the profiling of volatile compounds from spices using black pepper as an example. SPME profiles obtained in different analytical conditions were compared to the profile of pepper volatiles obtained using hydrodistillation in Clevenger apparatus. The profiles of both monoterpenes and sesquiterpenes of black pepper were highly dependent on sample weight (0.1 and 1g samples were tested), and extraction time (durations from 2 to 120min were tested), regardless of the SPME fiber used (PDMS and CAR/PDMS coatings were used). The characteristic phenomenon for extraction from dry ground pepper was the decrease of monoterpenes % share in volatiles with increasing extraction times, whereas at the same time the % contents of sesquiterpenes increased. Addition of water to ground pepper substantially changed extraction kinetics and mutual proportions of mono to sesquiterpenes compared to dry samples by minimizing changes in mono- to sesquiterpenes ratio in different extraction times. Obtained results indicate that SPME can be a fast extraction method for volatiles of black pepper. Short extraction times (2-10min) in conjunction with the fast GC analysis (2.1min) proposed here may offer fast alternative to hydrodistillation allowing black pepper terpenes characterization. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Headspace solid phase microextraction--GC/C-IRMS for delta13CVPDB measurements of mono-aromatic hydrocarbons using EA-IRMS calibration.

    PubMed

    Ebongué, Véronique Woule; Geypens, Benny; Berglund, Michael; Taylor, Philip

    2009-03-01

    This work aims at comparing the delta(13)C(VPDB) of mono-aromatic hydrocarbons benzene, toluene, ethylbenzene and xylene isomers (BTEX) measured by elemental analyser (EA)-isotope ratio mass spectrometer (IRMS) with the delta(13)C(VPDB) measured on the same compounds by headspace solid phase microextraction - GC/C-IRMS (hSPME - GC/C-IRMS) with the final goal of using these compounds as internal standards on the latter system. The EA-IRMS measurements were done using calcium and lithium carbonate isotopic reference materials: NBS19 and L-SVEC for establishing the delta(13)C(VPDB) scale. The EA-IRMS measurements with helium dilution of a set of five reference materials (USGS40, USGS41, IAEA-CH-6, IAEA-CH-3 and IAEA-601) show systematic bias of 1 per thousand relative to their assigned values. This bias due to the dilution mechanism in the used ConfloII interface device could not be avoided. As the selected hydrocarbons: BTEX could not be analysed by EA-IRMS without helium dilution, their delta(13)C(VPDB) must be corrected from this observed bias using an external calibration. The CO(2) gas calibrated using EA-IRMS without helium dilution, was used as an in-house reference for the delta(13)C(VPDB) measurements of the BTEX by the hSPME - GC/C-IRMS system. The comparison made between the delta(13)C(VPDB) measured on the same BTEX compounds by EA-IRMS (with external calibration) and by hSPME - GC/C-IRMS techniques showed good agreement.

  19. Ionic Liquid-Mediated Multi-Walled Carbon Nanotube-Polydimethylsiloxane Fiber for Headspace Solid-Phase Microextraction of Phenolic Compounds in Aqueous Samples by Gas Chromatography Coupled to Flame Ionization Detector.

    PubMed

    Sadri, Minoo; Vatani, Hossein

    2017-02-01

    An ionic liquid-mediated multi-walled carbon nanotube (MWCNT)-polydimethylsiloxane (PDMS) sorbent was developed for headspace solid-phase microextraction (HS-SPME) of phenolic compounds from human urine samples. Sol-gel method was used to prepare this sorbent. For this purpose, MWCNTs were functionalized covalently and were attached chemically to the hydroxyl-terminated PDMS. Prepared fiber showed high thermal stability (over than 320°C) and good lifespan (>210 times). These good performances can be attributed to the performance of carbon nanotubes and sol-gel method. Affecting parameters on the efficiency of HS-SPME were investigated and optimized. Under the optimal conditions, linear dynamic ranges were observed over a range of 0.002-200 ng mL -1 with limits of detection from 0.0005 to 0.005 ng mL -1 and limits of quantitation between 0.002 and 0.02 ng mL -1 The relative standard deviations for one fiber (repeatability) (n = 5) at three different concentrations (0.05, 2 and 100 ng mL -1 ) were obtained from 4.6 up to 6.7% and between fibers or batch to batch (n = 3) (reproducibility) in the range of 5.7-7.8%. Urine samples were used as real samples. All real samples were spiked at 0.5 ng mL -1 of understudy analytes and the relative recovery percentages obtained from 90.7 to 102.1%. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Rapid method for the simultaneous detection of boar taint compounds by means of solid phase microextraction coupled to gas chromatography/mass spectrometry.

    PubMed

    Verplanken, Kaat; Wauters, Jella; Van Durme, Jim; Claus, Dirk; Vercammen, Joeri; De Saeger, Sarah; Vanhaecke, Lynn

    2016-09-02

    Because of animal welfare issues, the voluntary ban on surgical castration of male piglets, starting January 2018 was announced in a European Treaty. One viable alternative is the fattening of entire male pigs. However, this can cause negative consumer reactions due to the occurrence of boar taint and possibly lead to severe economic losses in pig husbandry. In this study, headspace solid phase microextraction (HS-SPME) coupled to GC-MS was used in the development and optimization of a candidate method for fast and accurate detection of the boar taint compounds. Remarkably fast extraction (45s) of the boar taint compounds from adipose tissue was achieved by singeing the fat with a soldering iron while released volatiles were extracted in-situ using HS-SPME. The obtained method showed good performance characteristics after validation according to CD 2002/657/EC and ISO/IEC 17025 guidelines. Moreover, cross-validation with an in-house UHPLC-HR-Orbitrap-MS method showed good agreement between an in-laboratory method and the new candidate method for the fast extraction and detection of skatole and androstenone, which emphasizes the accuracy of this new SPME-GC-MS method. Threshold detection of the boar taint compounds on a portable GC-MS could not be achieved. However, despite the lack of sensitivity obtained on the latter instrument, a very fast method with run-to-run time of 3.5min for the detection of the boar taint compounds was developed. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. In Situ Hydrothermally Grown TiO2@C Core-Shell Nanowire Coating for Highly Sensitive Solid Phase Microextraction of Polycyclic Aromatic Hydrocarbons.

    PubMed

    Wang, Fuxin; Zheng, Juan; Qiu, Junlang; Liu, Shuqin; Chen, Guosheng; Tong, Yexiang; Zhu, Fang; Ouyang, Gangfeng

    2017-01-18

    Nanostructured materials have great potential for solid phase microextraction (SPME) on account of their tiny size, distinct architectures and superior physical and chemical properties. Herein, a core-shell TiO 2 @C fiber for SPME was successfully fabricated by the simple hydrothermal reaction of a titanium wire and subsequent amorphous carbon coating. The readily hydrothermal procedure afforded in situ synthesis of TiO 2 nanowires on a titanium wire and provided a desirable substrate for further coating of amorphous carbon. Benefiting from the much larger surface area of subsequent TiO 2 and good adsorption property of the amorphous carbon coating, the core-shell TiO 2 @C fiber was utilized for the SPME device for the first time and proved to have better performance in extraction of polycyclic aromatic hydrocarbons. In comparison to the polydimethylsiloxane (PDMS) and PDMS/divinylbenzene (DVB) fiber for commercial use, the TiO 2 @C fiber obtained gas chromatography responses 3-8 times higher than those obtained by the commercial 100 μm PDMS and 1-9 times higher than those obtained by the 65 μm PDMS/DVB fiber. Under the optimized extraction conditions, the low detection limits were obtained in the range of 0.4-7.1 ng L -1 with wider linearity in the range of 10-2000 ng L -1 . Moreover, the fiber was successfully used for the determination of polycyclic aromatic hydrocarbons in Pearl River water, which demonstrated the applicability of the core-shell TiO 2 @C fiber.

  2. Comparison of direct, headspace and headspace cold fiber modes in solid phase microextraction of polycyclic aromatic hydrocarbons by a new coating based on poly(3,4-ethylenedioxythiophene)/graphene oxide composite.

    PubMed

    Banitaba, Mohammad Hossein; Hosseiny Davarani, Saied Saeed; Kazemi Movahed, Siyavash

    2014-01-17

    A novel nanocomposite coating made of poly(3,4-ethylenedioxythiophene) (PEDOT) and graphene oxide was electrochemically prepared on gold wire. The prepared fiber was applied to the solid-phase microextraction (SPME) and gas chromatographic analysis of six polycyclic aromatic hydrocarbons (PAHs). Three modes of extraction i.e. direct immersion (DI), headspace (HS) and headspace cold fiber (HS-CF) in SPME were investigated. The results were compared under optimized conditions of each mode, considering the effects of the three most important parameters which are extraction temperature, extraction time and ionic strength. The comparison showed that HS-CF-SPME results in the best outcome for the extraction of PAHs from water samples. Under the optimized conditions of this mode, the calibration curves were linear within the range of 0.4-600μgL(-1) and the detection limits were between 0.05 and 0.13μgL(-1). The intra-day and inter-day relative standard deviations obtained at 10μgL(-1) (n=5), using a single fiber, were 4.1-6.8% and 4.8-8.4%, respectively. The fiber-to-fiber repeatabilities (n=4), expressed as the relative standard deviations (RSD%), were between 6.5% and 10.7% at a 10μgL(-1) concentration level. The method was successfully applied to the analysis of PAHs in seawater samples showing recoveries from 85% to 107%. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Optimization of a novel method for determination of benzene, toluene, ethylbenzene, and xylenes in hair and waste water samples by carbon nanotubes reinforced sol-gel based hollow fiber solid phase microextraction and gas chromatography using factorial experimental design.

    PubMed

    Es'haghi, Zarrin; Ebrahimi, Mahmoud; Hosseini, Mohammad-Saeid

    2011-05-27

    A novel design of solid phase microextraction fiber containing carbon nanotube reinforced sol-gel which was protected by polypropylene hollow fiber (HF-SPME) was developed for pre-concentration and determination of BTEX in environmental waste water and human hair samples. The method validation was included and satisfying results with high pre-concentration factors were obtained. In the present study orthogonal array experimental design (OAD) procedure with OA(16) (4(4)) matrix was applied to study the effect of four factors influencing the HF-SPME method efficiency: stirring speed, volume of adsorption organic solvent, extraction and desorption time of the sample solution, by which the effect of each factor was estimated using individual contributions as response functions in the screening process. Analysis of variance (ANOVA) was employed for estimating the main significant factors and their percentage contributions in extraction. Calibration curves were plotted using ten spiking levels of BTEX in the concentration ranges of 0.02-30,000ng/mL with correlation coefficients (r) 0.989-0.9991 for analytes. Under the optimized extraction conditions, the method showed good linearity (0.3-20,000ng/L), repeatability, low limits of detections (0.49-0.7ng/L) and excellent pre-concentration factors (185-1872). The best conditions which were estimated then applied for the analysis of BTEX compounds in the real samples. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Development of a fast and simple gas chromatographic protocol based on the combined use of alkyl chloroformate and solid phase microextraction for the assay of polyamines in human urine.

    PubMed

    Naccarato, Attilio; Elliani, Rosangela; Cavaliere, Brunella; Sindona, Giovanni; Tagarelli, Antonio

    2018-05-11

    Polyamines are aliphatic amines with low molecular weight that are widely recognized as one of the most important cancer biomarkers for early diagnosis and treatment. The goal of the work herein presented is the development of a rapid and simple method for the quantification of free polyamines (i.e., putrescine, cadaverine, spermidine, spermine) and N-monoacetylated polyamines (i.e., N 1 -Acetylspermidine, N 8 -Acetylspermidine, and N 1 -Acetylspermine) in human urine. A preliminary derivatization with propyl chloroformate combined with the use of solid phase microextraction (SPME) allowed for an easy and automatable protocol involving minimal sample handling and no consumption of organic solvents. The affinity of the analytes toward five commercial SPME coatings was evaluated in univariate mode, and the best result in terms of analyte extraction was achieved using the divinylbenzene/carboxen/polydimethylsiloxane fiber. The variables affecting the performance of SPME analysis were optimized by the multivariate approach of experimental design and, in particular, using a central composite design (CCD). The optimal working conditions in terms of response values are the following: extraction temperature 40 °C, extraction time of 15 min and no addition of NaCl. Analyses were carried out by gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS) in selected reaction monitoring (SRM) acquisition mode. The developed method was validated according to the guidelines issued by the Food and Drug Administration (FDA). The satisfactory performances reached in terms of linearity, sensitivity (LOQs between 0.01 and 0.1 μg/mL), matrix effect (68-121%), accuracy, and precision (inter-day values between -24% and +16% and in the range 3.3-28.4%, respectively) make the proposed protocol suitable to be adopted for quantification of these important biomarkers in urine samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Rapid and simultaneous determination of twenty amino acids in complex biological and food samples by solid-phase microextraction and gas chromatography-mass spectrometry with the aid of experimental design after ethyl chloroformate derivatization.

    PubMed

    Mudiam, Mohana Krishna Reddy; Ratnasekhar, Ch; Jain, Rajeev; Saxena, Prem Narain; Chauhan, Abhishek; Murthy, R C

    2012-10-15

    Amino acids play a vital role as intermediates in many important metabolic pathways such as the biosynthesis of nucleotides, vitamins and secondary metabolites. A sensitive and rapid analytical method has been proposed for the first time for the simultaneous determination of twenty amino acids using solid-phase microextraction (SPME). The protein samples were hydrolyzed by 6M HCl under microwave radiation for 120 min. Then the amino acids were derivatized by ethyl chloroformate (ECF) and the ethoxy carbonyl ethyl esters of amino acids formed were extracted using SPME by direct immersion. Finally the extracted analytes on the SPME fiber were desorbed at 260°C and analyzed by gas chromatography-mass spectrometer (GC-MS) in electron ionization mode. Factors which affect the SPME efficiency were screened by Plackett-Burmann design; most significant factors were optimized with response surface methodology. The optimum conditions for SPME are as follows: pH of 1.7, ionic strength of 733 mg, extraction time of 30 min and fiber of divinyl benzene/carboxen/polydimethylsiloxane (DVB/CAR/PDMS). The recovery of all the amino acids was found to be in the range of 89.17-100.98%. The limit of detection (LOD) of all derivatized amino acids in urine, hair and soybean was found to be in the range of 0.20-7.52 μg L(-1), 0.21-8.40 μg L(-1) and 0.18-5.62 μg L(-1), respectively. Finally, the proposed technique was successfully applied for the determination of amino acids in complex biological (hair, urine) and food samples (soybean). The method can find wide applications in the routine analysis of amino acids in any biological as well as food samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Simultaneous determination of traces of pyrethroids, organochlorines and other main plant protection agents in agricultural soils by headspace solid-phase microextraction-gas chromatography.

    PubMed

    Fernandez-Alvarez, Maria; Llompart, Maria; Lamas, J Pablo; Lores, Marta; Garcia-Jares, Carmen; Cela, Rafael; Dagnac, Thierry

    2008-04-25

    A solvent-free and simple method based on headspace solid-phase microextraction (HS-SPME) was developed in order to determine simultaneously 36 common pesticides and breakdown products (mostly pyrethroids and organochlorine compounds) in soil. The analysis was carried out by gas chromatography with micro-electron-capture detection (GC-microECD). As far as we know, this is the first study about the SPME of pyrethroid insecticides from soil. Factors such as extraction temperature, matrix modification by addition of water, salt addition (% NaCl) and fiber coating were considered in the optimization of the HS-SPME. To this end, a 3 x 2(3-1) fractional factorial design was performed. The results showed that temperature and fiber coating were the most significant variables affecting extraction efficiency. A suitable sensitivity for all investigated compounds was achieved at 100 degrees C by extracting soil samples wetted with 0.5 mL of ultrapure water (0% NaCl) employing a polyacrylate (PA) coating fiber. Using the recommended extraction conditions with GC-microECD, a linear calibration could be achieved over a range of two orders of magnitude for both groups of analytes. Limits of detection (LODS) at the sub-ng g(-1) level were attained and relative standard deviations (RSDs) were found to be lower than 14% for both groups of pesticides. Matrix effects were investigated by the analysis of different soil samples fortified with the target compounds. The method accuracy was assessed and good recovery values (>70%, in most cases) were obtained. The method was also validated with a certified reference material (RTC-CRM818-050), which was quantified using a standard addition protocol. Finally, the proposed HS-SPME-GC-microECD methodology was further applied to the screening of environmental soil samples for the presence of the target pesticides.

  7. In matrix derivatization of trichloroethylene metabolites in human plasma with methyl chloroformate and their determination by solid-phase microextraction-gas chromatography-electron capture detector.

    PubMed

    Mudiam, Mohana Krishna Reddy; Jain, Rajeev; Varshney, Meenu; Ch, Ratnasekhar; Chauhan, Abhishek; Goyal, Sudhir Kumar; Khan, Haider A; Murthy, R C

    2013-04-15

    Trichloroethylene (TCE) is a common industrial chemical that has been widely used as metal degreaser and for many industrial purposes. In humans, TCE is metabolized into dichloroacetic acid (DCA), trichloroacetic acid (TCA) and trichloroethanol (TCOH). A simple and rapid method has been developed for the quantitative determination of TCE metabolites. The procedure involves the in situ derivatization of TCE metabolites with methyl chloroformate (MCF) directly in diluted plasma samples followed by extraction and analysis with solid-phase microextraction (SPME) coupled to gas chromatography-electron capture detector (GC-ECD). Factors which can influence the efficiency of derivatization such as amount of MCF and pyridine (PYR), ratio of water/methanol were optimized. The factors which can affect the extraction efficiencies of SPME were screened using 2(7-4) Placket-Burman Design (PBD). A central composite design (CCD) was then applied to further optimize the most significant factors for optimum SPME extraction. The optimum factors for the SPME extraction were found to be 562.5mg of NaCl, pH at 1 and an extraction time of 22 min. Recoveries and detection limits of all three analytes in plasma were found to be in the range of 92.69-97.55% and 0.036-0.068 μg mL(-1) of plasma, respectively. The correlation coefficients were found to be in the range of 0.990-0.995. The intra- and inter-day precisions for TCE metabolites were found to be in the range of 2.37-4.81% and 5.13-7.61%, respectively. The major advantage of this method is that MCF derivatization allows conversion of TCE metabolites into their methyl esters in very short time (≤30 s) at room temperature directly in the plasma samples, thus makes it a solventless analysis. The method developed was successfully applied to the plasma samples of humans exposed to TCE. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Determination of N-vinyl-2-pyrrolidone and N-methyl-2-pyrrolidone in drugs using polypyrrole-based headspace solid-phase microextraction and gas chromatography-nitrogen-phosphorous detection.

    PubMed

    Mehdinia, Ali; Ghassempour, Alireza; Rafati, Hasan; Heydari, Rouhollah

    2007-03-21

    A headspace solid-phase microextraction and gas chromatography-nitrogen-phosphorous detection (HS-SPME-GC-NPD) method using polypyrrole (PPy) fibers has been introduced to determine two derivatives of pyrrolidone; N-vinyl-2-pyrrolidone (NVP) and N-methyl-2-pyrrolidone (NMP). Two types of PPy fibers, prepared using organic and aqueous media, were compared in terms of extraction efficiency and thermal stability. It was found that PPy film prepared using organic medium (i.e. acetonitrile) had higher extraction efficiency and more thermal stability compared to the film prepared in aqueous medium. To enhance the sensitivity of HS-SPME, the effects of pH, ionic strength, extraction time, extraction temperature and the headspace volume on the extraction efficiency were optimized. Using the results of this research, high sensitivity and selectivity had been achieved due to the combination of the high extraction efficiency of PPy film prepared in organic medium and the high sensitivity and selectivity of nitrogen-phosphorous detection. Linear range of the analytes was found to be between 1.0 and 1000 microg L(-1) with regression coefficients (R(2)) of 0.998 and 0.997 for NVP and NMP, consequently. Limits of detection (LODs) were 0.074 and 0.081 microg L(-1) for NVP and NMP, respectively. Relative standard deviation (R.S.D.) for five replications of analyses was found to be less than 6.0%. In real samples the mean recoveries were 94.81% and 94.15% for NVP and NMP, respectively. The results demonstrated the suitability of the HS-SPME technique for analyzing NVP and NMP in two different pharmaceutical matrices. In addition, the method was used for simultaneous detection of NVP, 2-pyrrolidone (2-Pyr), gamma-butyrolactone (GBL) and ethanolamine (EA) compounds.

  9. A molybdenum disulfide/reduced graphene oxide fiber coating coupled with gas chromatography-mass spectrometry for the saponification-headspace solid-phase microextraction of polychlorinated biphenyls in food.

    PubMed

    Lv, Fangying; Gan, Ning; Cao, Yuting; Zhou, You; Zuo, Rongjie; Dong, Youren

    2017-11-24

    In this work, the molybdenum disulfide/reduced graphene oxide (MoS 2 /RGO) composite material was synthesized as a fiber coating to extract seven indicator polychlorinated biphenyls (PCBs; PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, and PCB180) present in food via a saponification-headspace solid-phase microextraction assay (saponification-HS-SPME). The MoS 2 /RGO coating was prepared and deposited on a stainless steel wire with the help of a silicone sealant and used as an SPME fiber. The alkali solution dissolved the fat and helped in releasing the PCBs present in milk to the headspace for extraction under 100°C. Following desorption in the inlet, the targets were quantified by gas chromatography-mass spectrometry. The effects of sorbent dosage, extraction time, added salts, and stirring rate on the extraction efficiency were investigated. The new coating was able to adsorb a higher amount of analytes, which was about 1.1-2.9 times in comparison with the commercially available SPME fiber (coated with divinylbenzene/carboxen/polydimethylsiloxane). It also showed the highest adsorption capability toward PCBs, which was 1.5-2.7 times that of the prepared RGO modified fiber. Moreover, MoS 2 also showed a strong affinity toward PCBs in a manner similar to its affinity for graphene. The developed method is simple and environmentally friendly as it does not require any organic solvents. Furthermore, it exhibits good sensitivity with detection limits less than 0.1ngmL -1 , linearity (0.25-100ngmL -1 ), and reproducibility (relative standard deviation below 10% for n=3). The novel SPME fibers are inexpensive, reusable, and can be easily prepared and manipulated. In addition, the saponification-HS-SPME assay was also found to be suitable for screening persistent organic pollutants in dairy products. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Multiwalled carbon nanotubes coated fibers for solid-phase microextraction of polybrominated diphenyl ethers in water and milk samples before gas chromatography with electron-capture detection.

    PubMed

    Wang, Jun-Xia; Jiang, Dong-Qing; Gu, Zhi-Yuan; Yan, Xiu-Ping

    2006-12-22

    Determination of polybrominated diphenyl ethers (PBDEs) in environmental samples has raised great concerns due to the widespread use of PBDEs and their potential risk to humans. Solid-phase microextraction (SPME) is a fast, simple, cost-effective, and green sample preparation technique and is widely used for environmental analysis, but reports on the application of SPME for determination of PBDEs are very limited, and only a few publications dealing with commercial SPME fibers are available for extraction of PBDEs. Herein, we report a novel SPME method using multiwalled carbon nanotubes (MWCNTs) as the SPME fiber coating for gas chromatography with electron-capture detection (GC-ECD) of PBDEs in environmental samples. The MWCNTs coating gave much higher enhancement factors (616-1756) than poly (5% dibenzene-95% dimethylsiloxane) coating (139-384) and activated carbon coating (193-423). Thirty-minute extraction of 10 mL of sample solution using the MWCNTs coated fiber for GC-ECD determination yielded the limits of detection of 3.6-8.6 ng L(-1) and exhibited good linearity of the calibration functions (r(2)>0.995). The precision (RSD%, n=4) for peak area and retention time at the 500 ng L(-1) level was 6.9-8.8% and 0.6-0.9%, respectively. The developed method was successfully applied for the analysis of real samples including local river water, wastewater, and milk samples. The recovery of the PBDEs at 500 ng L(-1) spiked in these samples ranged from 90 to 119%. No PBDEs were detected in the river water and skimmed milk samples, whereas in the wastewater sample, 134-215 ng L(-1) of PBDEs were found. The PBDEs were detected in all whole fat milk samples, ranging from 13 to 484 ng L(-1). In a semiskimmed milk sample, only BDE-47 was found at 21 ng L(-1).

  11. Ultrasound-assisted leaching-dispersive solid-phase extraction followed by liquid-liquid microextraction for the determination of polybrominated diphenyl ethers in sediment samples by gas chromatography-tandem mass spectrometry.

    PubMed

    Fontana, Ariel R; Lana, Nerina B; Martinez, Luis D; Altamirano, Jorgelina C

    2010-06-30

    Ultrasound-assisted leaching-dispersive solid-phase extraction followed by dispersive liquid-liquid microextraction (USAL-DSPE-DLLME) technique has been developed as a new analytical approach for extracting, cleaning up and preconcentrating polybrominated diphenyl ethers (PBDEs) from sediment samples prior gas chromatography-tandem mass spectrometry (GC-MS/MS) analysis. In the first place, PBDEs were leached from sediment samples by using acetone. This extract was cleaned-up by DSPE using activated silica gel as sorbent material. After clean-up, PBDEs were preconcentrated by using DLLME technique. Thus, 1 mL acetone extract (disperser solvent) and 60 microL carbon tetrachloride (extraction solvent) were added to 5 mL ultrapure water and a DLLME technique was applied. Several variables that govern the proposed technique were studied and optimized. Under optimum conditions, the method detection limits (MDLs) of PBDEs calculated as three times the signal-to-noise ratio (S/N) were within the range 0.02-0.06 ng g(-1). The relative standard deviations (RSDs) for five replicates were <9.8%. The calibration graphs were linear within the concentration range of 0.07-1000 ng g(-1) for BDE-47, 0.09-1000 ng g(-1) for BDE-100, 0.10-1000 ng g(-1) for BDE-99 and 0.19-1000 ng g(-1) for BDE-153 and the coefficients of estimation were > or =0.9991. Validation of the methodology was carried out by standard addition method at two concentration levels (0.25 and 1 ng g(-1)) and by comparing with a reference Soxhlet technique. Recovery values were > or =80%, which showed a satisfactory robustness of the analytical methodology for determination of low PBDEs concentration in sediment samples. Copyright 2010 Elsevier B.V. All rights reserved.

  12. Evaluation of sample recovery of malodorous livestock gases from air sampling bags, solid-phase microextraction fibers, Tenax TA sorbent tubes, and sampling canisters.

    PubMed

    Koziel, Jacek A; Spinhirne, Jarett P; Lloyd, Jenny D; Parker, David B; Wright, Donald W; Kuhrt, Fred W

    2005-08-01

    Odorous gases associated with livestock operations are complex mixtures of hundreds if not thousands of compounds. Research is needed to know how best to sample and analyze these compounds. The main objective of this research was to compare recoveries of a standard gas mixture of 11 odorous compounds from the Carboxen/PDMS 75-microm solid-phase microextraction fibers, polyvinyl fluoride (PVF; Tedlar), fluorinated ethylene propylene copolymer (FEP; Teflon), foil, and polyethylene terephthalate (PET; Melinex) air sampling bags, sorbent 2,b-diphenylene-oxide polymer resin (Tenax TA) tubes, and standard 6-L Stabilizer sampling canisters after sample storage for 0.5, 24, and 120 (for sorbent tubes only) hrs at room temperature. The standard gas mixture consisted of 7 volatile fatty acids (VFAs) from acetic to hexanoic, and 4 semivolatile organic compounds including p-cresol, indole, 4-ethylphenol, and 2'-aminoacetophenone with concentrations ranging from 5.1 ppb for indole to 1270 ppb for acetic acid. On average, SPME had the highest mean recovery for all 11 gases of 106.2%, and 98.3% for 0.5- and 24-hr sample storage time, respectively. This was followed by the Tenax TA sorbent tubes (94.8% and 88.3%) for 24 and 120 hr, respectively; PET bags (71.7% and 47.2%), FEP bags (75.4% and 39.4%), commercial Tedlar bags (67.6% and 22.7%), in-house-made Tedlar bags (47.3% and 37.4%), foil bags (16.4% and 4.3%), and canisters (4.2% and 0.5%), for 0.5 and 24 hr, respectively. VFAs had higher recoveries than semivolatile organic compounds for all of the bags and canisters. New FEP bags and new foil bags had the lowest and the highest amounts of chemical impurities, respectively. New commercial Tedlar bags had measurable concentrations of N,N-dimethyl acetamide and phenol. Foil bags had measurable concentrations of acetic, propionic, butyric, valeric, and hexanoic acids.

  13. Analysis of halonitriles in drinking water using solid-phase microextraction and gas chromatography-mass spectrometry.

    PubMed

    Kristiana, Ina; Joll, Cynthia; Heitz, Anna

    2012-02-17

    Halonitriles are a class of nitrogen-containing disinfection by-products (DBPs) that have been reported to be more toxic and carcinogenic than the regulated DBPs. While haloacetonitriles (HANs) are often measured in drinking waters, there is little information on the formation, characteristics, and occurrence of other, higher molecular weight halonitriles. Halopropionitriles and halobutyronitriles have been predicted to be highly toxic and carcinogenic, and may have sufficient potency and selectivity to account for epidemiological associations of chlorinated and chloraminated water with adverse health effects. This paper reports on the development, optimisation, and validation of a simple, robust, and sensitive analytical method for the determination of halonitriles in waters, as well as the application of the method to study the formation and characteristics of halonitriles. This is the first reported method development for analysis halopropionitriles and halobutyronitriles, and the first study on their formation and occurrence as DBPs in drinking waters. The new method uses headspace solid-phase microextraction to extract the halonitriles from water, which are then analysed using gas chromatography-mass spectrometry (HS SPME/GC-S). The method demonstrated good sensitivity (detection limits: 0.9-80 ng L⁻¹) and good precision (repeatability: 3.8-12%), and is linear over three orders of magnitude. Matrix effects from raw drinking water containing organic carbon (4.1 mg L⁻¹) were shown to be negligible in the analysis of halonitriles. The optimised method was used to study the stability and persistence of halonitriles in aqueous samples, and the formation and occurrence of halonitriles in waters. Results from laboratory-scale disinfection experiments showed that haloacetonitriles were formed in chlorinated and chloraminated samples, but 2,2-dichloropropionitrile was only measured in chloraminated samples. Results from surveys of several drinking water distribution systems confirmed the laboratory findings. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Automated direct-immersion solid-phase microextraction using crosslinked polymeric ionic liquid sorbent coatings for the determination of water pollutants by gas chromatography.

    PubMed

    Cordero-Vaca, María; Trujillo-Rodríguez, María J; Zhang, Cheng; Pino, Verónica; Anderson, Jared L; Afonso, Ana M

    2015-06-01

    Four different crosslinked polymeric ionic liquid (PIL)-based sorbent coatings were evaluated in an automated direct-immersion solid-phase microextraction method (automated DI-SPME) in combination with gas chromatography (GC). The crosslinked PIL coatings were based on vinyl-alkylimidazolium- (ViCnIm-) or vinylbenzyl-alkylimidazolium- (ViBzCnIm-) IL monomers, and di-(vinylimidazolium)dodecane ((ViIm)2C12-) or di-(vinylbenzylimidazolium)dodecane ((ViBzIm)2C12-) dicationic IL crosslinkers. In addition, a PIL-based hybrid coating containing multi-walled carbon nanotubes (MWCNTs) was also studied. The studied PIL coatings were covalently attached to derivatized nitinol wires and mounted onto the Supelco assembly to ensure automation when acting as SPME coatings. Their behavior was evaluated in the determination of a group of water pollutants, after proper optimization. A comparison was carried out with three common commercial SPME fibers. It was observed that those PILs containing a benzyl group in their structures, either in the IL monomer and crosslinker (PIL-1-1) or only in the crosslinker (PIL-0-1), were the most efficient sorbents for the selected analytes. The validation of the overall automated DI-SPME-GC-flame ionization detector (FID) method gave limits of detection down to 135 μg · L(-1) for p-cresol when using the PIL-1-1 and down to 270 μg · L(-1) when using the PIL-0-1; despite their coating thickness: ~2 and ~5 μm, respectively. Average relative recoveries with waters were of 85 ± 14 % and 87 ± 15 % for PIL-1-1 and PIL-0-1, respectively. Precision values as relative standard deviation were always lower than 4.9 and 7.6 % (spiked level between 10 and 750 μg · L(-1), as intra-day precision). Graphical Abstract Automated DI-SPME-GC-FID using crosslinked-PILs sorbent coatings for the determination of waterpollutants.

  15. Development of a New Microextraction Fiber Combined to On-Line Sample Stacking Capillary Electrophoresis UV Detection for Acidic Drugs Determination in Real Water Samples.

    PubMed

    Espina-Benitez, Maria; Araujo, Lilia; Prieto, Avismelsi; Navalón, Alberto; Vílchez, José Luis; Valera, Paola; Zambrano, Ana; Dugas, Vincent

    2017-07-07

    A new analytical method coupling a (off-line) solid-phase microextraction with an on-line capillary electrophoresis (CE) sample enrichment technique was developed for the analysis of ketoprofen, naproxen and clofibric acid from water samples, which are known as contaminants of emerging concern in aquatic environments. New solid-phase microextraction fibers based on physical coupling of chromatographic supports onto epoxy glue coated needle were studied for the off-line preconcentration of these micropollutants. Identification and quantification of such acidic drugs were done by capillary zone electrophoresis (CZE) using ultraviolet diode array detection (DAD). Further enhancement of concentration sensitivity detection was achieved by on-line CE "acetonitrile stacking" preconcentration technique. Among the eight chromatographic supports investigated, Porapak Q sorbent showed higher extraction and preconcentration capacities. The screening of parameters that influence the microextraction process was carried out using a two-level fractional factorial. Optimization of the most relevant parameters was then done through a surface response three-factor Box-Behnken design. The limits of detection and limits of quantification for the three drugs ranged between 0.96 and 1.27 µg∙L -1 and 2.91 and 3.86 µg∙L -1 , respectively. Recovery yields of approximately 95 to 104% were measured. The developed method is simple, precise, accurate, and allows quantification of residues of these micropollutants in Genil River water samples using inexpensive fibers.

  16. Development of a New Microextraction Fiber Combined to On-Line Sample Stacking Capillary Electrophoresis UV Detection for Acidic Drugs Determination in Real Water Samples

    PubMed Central

    Araujo, Lilia; Prieto, Avismelsi; Navalón, Alberto; Vílchez, José Luis; Valera, Paola; Zambrano, Ana; Dugas, Vincent

    2017-01-01

    A new analytical method coupling a (off-line) solid-phase microextraction with an on-line capillary electrophoresis (CE) sample enrichment technique was developed for the analysis of ketoprofen, naproxen and clofibric acid from water samples, which are known as contaminants of emerging concern in aquatic environments. New solid-phase microextraction fibers based on physical coupling of chromatographic supports onto epoxy glue coated needle were studied for the off-line preconcentration of these micropollutants. Identification and quantification of such acidic drugs were done by capillary zone electrophoresis (CZE) using ultraviolet diode array detection (DAD). Further enhancement of concentration sensitivity detection was achieved by on-line CE “acetonitrile stacking” preconcentration technique. Among the eight chromatographic supports investigated, Porapak Q sorbent showed higher extraction and preconcentration capacities. The screening of parameters that influence the microextraction process was carried out using a two-level fractional factorial. Optimization of the most relevant parameters was then done through a surface response three-factor Box-Behnken design. The limits of detection and limits of quantification for the three drugs ranged between 0.96 and 1.27 µg∙L−1 and 2.91 and 3.86 µg∙L−1, respectively. Recovery yields of approximately 95 to 104% were measured. The developed method is simple, precise, accurate, and allows quantification of residues of these micropollutants in Genil River water samples using inexpensive fibers. PMID:28686186

  17. Evaluating PCB Bioavailability Using Passive Samplers and Mussles at a Contaminated Sediment Site

    EPA Science Inventory

    Passive samplers, including semi-permeable membrane devices (SPMDs), solid phase microextraction (SPME) and polyethylene devices (PEDs), provide innovative tools for measuring hydrophobic organic contaminants (HOCs) originating from contaminated waters and sediments. Because the...

  18. Solid-phase microextraction for qualitative and quantitative determination of migrated degradation products of antioxidants in an organic aqueous solution.

    PubMed

    Burman, Lina; Albertsson, Ann-Christine; Höglund, Anders

    2005-07-08

    Low molecular weight aromatic substances may migrate out from plastic packaging to their contents, especially if they consist of organic aqueous solutions or oils. It is, therefore, extremely important to be able to identify and quantify any migrated substances in such solutions, even at very low concentrations. We have in this work investigated and evaluated the use of solid-phase microextraction for the specific task of extraction from an organic aqueous solution such as a simulated pharmaceutical solution consisting of 10 vol.% ethanol in water. The goal was furthermore to investigate the possibility of simultaneously identifying and quantifying the substances in spite of differences in their chemical structures. Methods were developed and evaluated for extraction both with direct sampling and with headspace sampling. Difficulties appeared due to the ethanol in the solution and the minute amounts of substances present. We have shown that a simultaneous quantification of migrated low molecular weight degradation products of antioxidants using only one fibre is possible if the extraction method and temperature are adjusted in relation to the concentration levels of the analytes. Comparions were made with solid-phase extraction.

  19. Evaluation of in vivo solid phase microextraction for minimally invasive analysis of nonvolatile phytochemicals in Amazonian plants.

    PubMed

    Musteata, Florin Marcel; Sandoval, Manuel; Ruiz-Macedo, Juan C; Harrison, Kathleen; McKenna, Dennis; Millington, William

    2016-08-24

    Although solid phase microextraction (SPME) has been used extensively for fingerprinting volatile compounds emitted by plants, there are very few such reports for direct insertion SPME. In this research, direct contact of SPME probes with the interstitial fluid of plants was investigated as a method for phytochemical analysis. Medicinal plants from the Amazon have been the source of numerous drugs used in western medicine. However, a large number of species used in traditional medicine have not been characterized chemically, partly due to the difficulty of field work. In this project, the phytochemical composition of plants from several genera was fingerprinted by combining convenient field sampling by solid phase microextraction (SPME) with laboratory analysis by LC-MS. The new method was compared with classical sampling followed by liquid extraction (LE). SPME probes were prepared by coating stainless steel wires with a mixture of polyacrylonitrile and either RP-amide or HS-F5 silica particles. Sampling was performed by inserting the microextraction probes into various tissues of living plants in their natural environment. After in vivo extraction, the probes were sealed under vacuum and refrigerated until analyzed. The probes were desorbed in mobile phase and analyzed on a Waters Acquity UPLC with triple quadrupole mass spectrometer in positive ion mode. Twenty Amazonian plant species were sampled and unique metabolomic fingerprints were obtained. In addition, quantitative analysis was performed for previously identified compounds in three species. Comparison of the fingerprints obtained by in vivo SPME with those obtained by LE showed that 27% of the chromatographic features were unique to SPME, 57% were unique to LE, and 16% were common to both methods. In vivo SPME caused minimal damage to the plants, was much faster than traditional liquid extraction, and provided unique fingerprints for all investigated plants. SPME revealed unique chromatographic features, undetected by traditional extraction, although it produced only half as many peaks as ethanol extraction. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Development of a simple and rapid solid phase microextraction-gas chromatography-triple quadrupole mass spectrometry method for the analysis of dopamine, serotonin and norepinephrine in human urine.

    PubMed

    Naccarato, Attilio; Gionfriddo, Emanuela; Sindona, Giovanni; Tagarelli, Antonio

    2014-01-31

    The work aims at developing a simple and rapid method for the quantification of dopamine (DA), serotonin (5-HT) and norepinephrine (NE) in human urine. The urinary levels of these biogenic amines can be correlated with several pathological conditions concerning heart disease, stress, neurological disorders and cancerous tumors. The proposed analytical approach is based on the use of solid phase microextraction (SPME) combined with gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS) after a fast derivatization of both aliphatic amino and phenolic moieties by propyl chloroformate. The variables influencing the derivatization reaction were reliably optimized by the multivariate approach of "Experimental design". The optimal conditions were obtained by performing derivatization with 100μL of propyl chloroformate and 100μL of pyridine. The extraction ability of five commercially available SPME fibers was evaluated in univariate mode and the best results were obtained using the polyacrylate fiber. The variables affecting the efficiency of SPME analysis were again optimized by the multivariate approach of "Experimental design" and, in particular, a central composite design (CCD) was applied. The optimal values were extraction in 45min at room temperature, desorption temperature at 300°C, no addition of NaCl. Assay of derivatized analytes was performed by using a gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS) system in selected reaction monitoring (SRM) acquisition. An evaluation of all analytical parameters demonstrates that the developed method provides satisfactory results. Indeed, very good linearities were achieved in the tested calibration range with correlation coefficient values of 0.9995, 0.9999 and 0.9997 for DA, 5-HT and NE, respectively. Accuracies and RSDs calculated for between-run and tested at concentrations of 30, 200, and 800μg L(-1) were in the range from 92.8% to 103.0%, and from 0.67 to 4.5%, respectively. Finally, the LOD values obtained can be considered very good (0.587, 0.381 and 1.23μg L(-1) for DA, 5-HT and NE, respectively). Copyright © 2013 Elsevier B.V. All rights reserved.

  1. A solid-phase microextraction-gas chromatographic approach combined with triple quadrupole mass spectrometry for the assay of carbamate pesticides in water samples.

    PubMed

    Cavaliere, Brunella; Monteleone, Marcello; Naccarato, Attilio; Sindona, Giovanni; Tagarelli, Antonio

    2012-09-28

    A simple and sensitive method was developed for the quantification of five carbamate pesticides in water samples using solid phase microextraction (SPME) combined with gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS). The performance of five SPME fibers was tested in univariate mode whereas the other variables affecting the efficiency of SPME analysis were optimized by the multivariate approach of design of experiment (DoE) and, in particular, a central composite design (CCD) was applied. The optimum working conditions in terms of response values were achieved by performing analysis with polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber in immersion mode for 45min at room temperature with addition of NaCl (10%). The multivariate chemometric approach was also used to explore the chromatographic behavior of the carbamates and to evaluate the importance of each variable investigated. An overall appraisement of results shows that the factor which gave a statistically significant effect on the response was only the injection temperature. Identification and quantification of carbamates was performed by using a gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS) system in multiple reaction monitoring (MRM) acquisition. Since the choice of internal standard represented a crucial step in the development of method to achieve good reproducibility and robustness for the entire analytical protocol, three compounds (2,3,5-trimethacarb, 4-bromo-3,5-dimethylphenyl-n-methylcarbamate (BDMC) and carbaryl-d7) were evaluated as internal standards. Both precision and accuracy of the proposed protocol tested at concentration of 0.08, 5 and 3 μg l⁻¹ offered values ranging from 70.8% and 115.7% (except for carbaryl at 3 μg l⁻¹) and from 1.0% and 9.0% for accuracy and precision, respectively. Moreover, LOD and LOQ values ranging from 0.04 to 1.7 ng l⁻¹ and from 0.64 to 2.9 ng l⁻¹, respectively, can be considered very satisfactory. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Solid phase microextraction-comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry for the analysis of honey volatiles.

    PubMed

    Cajka, Tomás; Hajslová, Jana; Cochran, Jack; Holadová, Katerina; Klimánková, Eva

    2007-03-01

    Head-space solid phase microextration (SPME), followed by comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry (GCxGC-TOFMS), has been implemented for the analysis of honey volatiles, with emphasis on the optimal selection of SPME fibre and the first- and second-dimension GC capillaries. From seven SPME fibres investigated, a divinylbenzene/Carboxen/polydimethylsiloxane (DVB/CAR/PDMS) 50/30 microm fibre provided the best sorption capacity and the broadest range of volatiles extracted from the headspace of a mixed honey sample. A combination of DB-5ms x SUPELCOWAX 10 columns enabled the best resolution of sample components compared to the other two tested column configurations. Employing this powerful analytical strategy led to the identification of 164 volatile compounds present in a honey mixture during a 19-min GC run. Combination of this simple and inexpensive SPME-based sampling/concentration technique with the advanced separation/identification approach represented by GCxGC-TOFMS allows a rapid and comprehensive examination of the honey volatiles profile. In this way, the laboratory sample throughput can be increased significantly and, at the same time, the risk of erroneous identification, which cannot be avoided in one-dimensional GC separation, is minimised.

  3. Solid-phase extraction assisted dispersive liquid-liquid microextraction based on solidification of floating organic droplet to determine sildenafil and its analogues in dietary supplements.

    PubMed

    Li, Jing; Roh, Si Hun; Shaodong, Jia; Hong, Ji Yeon; Lee, Dong-Kyu; Shin, Byong-Kyu; Park, Jeong Hill; Lee, Jeongmi; Kwon, Sung Won

    2017-08-01

    A novel analytical method for the simultaneous determination of the concentration of sildenafil and its five analogues in dietary supplements using solid-phase extraction assisted reversed-phase dispersive liquid-liquid microextraction based on solidification of floating organic droplet combined with ion-pairing liquid chromatography with an ultraviolet detector was developed. Parameters that affect extraction efficiency were systematically investigated, including the type of solid-phase extraction cartridge, pH of the extraction environment, and the type and volume of extraction and dispersive solvent. The method linearity was in the range of 5.0-100 ng/mL for sildenafil, homosildenafil, udenafil, benzylsildenafil, and thiosildenafil and 10-100 ng/mL for acetildenafil. The coefficients of determination were ≥0.996 for all regression curves. The sensitivity values expressed as limit of detection were between 2.5 and 7.5 ng/mL. Furthermore, intraday and interday precisions expressed as relative standard deviations were less than 5.7 and 9.9%, respectively. The proposed method was successfully applied to the analysis of sildenafil and its five analogues in complex dietary supplements. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Bacterial Volatile Discovery using Solid Phase Microextraction and Comprehensive Two-Dimensional Gas Chromatography–Time-of-Flight Mass Spectrometry

    PubMed Central

    Bean, Heather D.; Dimandja, Jean-Marie D.; Hill, Jane E.

    2014-01-01

    Bacteria produce unique volatile mixtures that could be used to identify infectious agents to the species, and possibly the strain level. However, due to the immense variety of human pathogens, and the close relatedness of some of these bacteria, the robust identification of the bacterium based on its volatile metabolome is likely to require a large number of volatile compounds for each species. We applied comprehensive two-dimensional gas chromatography–time-of-flight mass spectrometry (GC×GC-TOFMS) to the identification of the headspace volatiles of P. aeruginosa PA14 grown for 24 h in lysogeny broth. This is the first reported use of GC×GC-TOFMS for the characterization of bacterial headspace volatiles. The analytical purity that is afforded by this chromatographic method facilitated the identification of 28 new P. aeruginosa-derived volatiles, nearly doubling the list of volatiles for this species. PMID:22727751

  5. Pedologic Factors Affecting Virgin Olive Oil Quality of "Chemlali" Olive Trees (Olea europaea L.).

    PubMed

    Rached, Mouna Ben; Galaverna, Gianni; Cirlini, Martina; Boujneh, Dalenda; Zarrouk, Mokhtar; Guerfel, Mokhtar

    2017-08-01

    The aim of this study examined the characterization of extra virgin olive oil samples from the main cultivar Chemlali, grown in five olive orchards with different soil type (Sandy, Clay, Stony, Brown, Limestone and Gypsum). Volatile compounds were studied using headspace-solid phase micro-extraction (HS-SPME) and gas chromatography-mass spectrometry (GC-MS) technics. Moreover, the sterol profile was established using gas chromatography-mass spectrometry. 35 different volatile compounds were identified: alcohols, esters, aldehydes, ketones and hydrocarbons. The chemical composition of the volatile fraction was characterized by the preeminence of 2-hexenal (32.75%) and 1-hexanol (31.88%). Three sterols were identified and characterized. For all olive oil samples, ß-sitosterol (302.25 mg/kg) was the most abundant sterol. Interestingly, our results showed significant qualitative and quantitative differences in the levels of the volatile compounds and sterols from oils obtained from olive trees grown in different soil type.

  6. Three-way principal component analysis of the volatile fraction by HS-SPME/GC of aceto balsamico tradizionale of modena.

    PubMed

    Cocchi, Marina; Durante, Caterina; Grandi, Margherita; Manzini, Daniela; Marchetti, Andrea

    2008-01-15

    The present research is aimed at monitoring the evolution of the volatile organic compounds of different samples of aceto balsamico tradizionale of modena (ABTM) during ageing. The flavouring compounds, headspace fraction, of the vinegars of four batterie were sampled by solid phase microextraction technique (SPME), and successively analysed by gas chromatography. Obtaining a data set characterized by different sources of variability such as, different producers, samples of different age and chromatographic profile. The gas chromatographic signals were processed by a three-way data analysis method (Tucker3), which allows an easy visualisation of the data by furnishing a distinct set of graphs for each source of variability. The obtained results indicate that the samples can be separated according to their age highlighting the chemical constituents, which play a major role for their differentiation. The present study represents an example of how the application of Tucker3 models, on gas chromatographic signals may help to follow the transformation processes of food products.

  7. Olfactometry Profiles and Quantitation of Volatile Sulfur Compounds of Swiss Tilsit Cheeses.

    PubMed

    Fuchsmann, Pascal; Stern, Mireille Tena; Brügger, Yves-Alain; Breme, Katharina

    2015-09-02

    To establish the odor profiles of three differently fabricated commercial Swiss Tilsit cheeses, analyses were conducted using headspace solid-phase microextraction gas chromatography-mass spectrometry/pulsed flame photometric detection and gas chromatography-olfactometry to identify and quantitate volatile compounds. In addition, odor quality and the impact of target sulfur compounds on the overall odor of the cheeses were investigated. The odor profile was found to be mainly influenced by buttery-cheesy and sulfury odor notes in all cheeses. Buttery-cheesy odor notes were attributed to three main molecules: butanoic acid, 3-methylbutanoic acid, and butane-2,3-dione. Over a dozen volatile sulfur compounds were detected at parts per billion levels, but only a few influenced the odor profile of the cheeses: methanethiol, dimethyl disulfide, bis(methylthio)methane, dimethyl trisulfide, 3-(methylthio)propanal, and 2-methyltetrahydrothiophen-3-one (tentative). In conclusion, the conducted analyses allowed differentiation of the cheeses, and gas chromatography-olfactometry results confirmed that partially thermized milk cheese has a more intense and more multifaceted overall flavor.

  8. Off-flavor related volatiles in soymilk as affected by soybean variety, grinding, and heat-processing methods.

    PubMed

    Zhang, Yan; Guo, Shuntang; Liu, Zhisheng; Chang, Sam K C

    2012-08-01

    Off-flavor of soymilk is a barrier to the acceptance of consumers. The objectionable soy odor can be reduced through inhibition of their formation or through removal after being formed. In this study, soymilk was prepared by three grinding methods (ambient, cold, and hot grinding) from two varieties (yellow Prosoy and a black soybean) before undergoing three heating processes: stove cooking, one-phase UHT (ultrahigh temperature), and two-phase UHT process using a Microthermics direct injection processor, which was equipped with a vacuuming step to remove injected water and volatiles. Eight typical soy odor compounds, generated from lipid oxidation, were extracted by a solid-phase microextraction method and analyzed by gas chromatography. The results showed that hot grinding and cold grinding significantly reduced off-flavor as compared with ambient grinding, and hot grinding achieved the best result. The UHT methods, especially the two-phase UHT method, were effective to reduce soy odor. Different odor compounds showed distinct concentration patterns because of different formation mechanisms. The two varieties behaved differently in odor formation during the soymilk-making process. Most odor compounds could be reduced to below the detection limit through a combination of hot grinding and two-phase UHT processing. However, hot grinding gave lower solid and protein recoveries in soymilk.

  9. Analytical methodologies for broad metabolite coverage of exhaled breath condensate.

    PubMed

    Aksenov, Alexander A; Zamuruyev, Konstantin O; Pasamontes, Alberto; Brown, Joshua F; Schivo, Michael; Foutouhi, Soraya; Weimer, Bart C; Kenyon, Nicholas J; Davis, Cristina E

    2017-09-01

    Breath analysis has been gaining popularity as a non-invasive technique that is amenable to a broad range of medical uses. One of the persistent problems hampering the wide application of the breath analysis method is measurement variability of metabolite abundances stemming from differences in both sampling and analysis methodologies used in various studies. Mass spectrometry has been a method of choice for comprehensive metabolomic analysis. For the first time in the present study, we juxtapose the most commonly employed mass spectrometry-based analysis methodologies and directly compare the resultant coverages of detected compounds in exhaled breath condensate in order to guide methodology choices for exhaled breath condensate analysis studies. Four methods were explored to broaden the range of measured compounds across both the volatile and non-volatile domain. Liquid phase sampling with polyacrylate Solid-Phase MicroExtraction fiber, liquid phase extraction with a polydimethylsiloxane patch, and headspace sampling using Carboxen/Polydimethylsiloxane Solid-Phase MicroExtraction (SPME) followed by gas chromatography mass spectrometry were tested for the analysis of volatile fraction. Hydrophilic interaction liquid chromatography and reversed-phase chromatography high performance liquid chromatography mass spectrometry were used for analysis of non-volatile fraction. We found that liquid phase breath condensate extraction was notably superior compared to headspace extraction and differences in employed sorbents manifested altered metabolite coverages. The most pronounced effect was substantially enhanced metabolite capture for larger, higher-boiling compounds using polyacrylate SPME liquid phase sampling. The analysis of the non-volatile fraction of breath condensate by hydrophilic and reverse phase high performance liquid chromatography mass spectrometry indicated orthogonal metabolite coverage by these chromatography modes. We found that the metabolite coverage could be enhanced significantly with the use of organic solvent as a device rinse after breath sampling to collect the non-aqueous fraction as opposed to neat breath condensate sample. Here, we show the detected ranges of compounds in each case and provide a practical guide for methodology selection for optimal detection of specific compounds. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. HS-SPME analysis of volatile organic compounds of coniferous needle litter

    NASA Astrophysics Data System (ADS)

    Isidorov, V. A.; Vinogorova, V. T.; Rafałowski, K.

    The composition of volatile emission of Scots pine ( Pinus sylvestris) and spruce ( Picea exelsa) litter was studied by gas chromatography-mass spectrometry (GC-MS) and samples were collected by solid-phase microextraction (SPME) method. The list of identified compounds includes over 60 organic substances of different classes. It was established that volatile emission contain not only components of essential oils of pine and spruce needles but also a large number of organic compounds which are probably secondary metabolites of litter-decomposing fungi. They include lower carbonyl compounds and alcohols as well as products of terpene dehydration and oxidation. These data show that the processes of litter decomposition are an important source of reactive organic compounds under canopy of coniferous forests.

  11. [Comparison of green coffee beans volatiles chemical composition of Hainan main area].

    PubMed

    Hu, Rong-Suo; Chu, Zhong; Gu, Feng-Lin; Lu, Min-Quan; Lu, Shao-Fang; Wu, Gui-Ping; Tan, Le-He

    2013-02-01

    Chemical component of Hainan green coffee beans was analyzed with solid phase microextraction-gas chromatography-mass spectrometry, and the discrepancy between two green coffee beans was differentiated through the spectrum database retrieval and retention index of compound characterization. The experimental results show that: the chemical composition of Wanning coffee beans and Chengmai coffee beans is basically the same. The quantity of analyzed compound in Wanning area coffee is 91, and in Chengmai area coffee is 106, the quantity of the same compound is 66, and the percent of the same component is 75.52%. The same compounds accounted for 89.86% of the total content of Wanning area coffee, and accounted for 85.70% of the total content of Chengmai area coffee.

  12. Volatile compounds of dry beans (Phaseolus vulgaris L.).

    PubMed

    Oomah, B Dave; Liang, Lisa S Y; Balasubramanian, Parthiba

    2007-12-01

    Volatile compounds of uncooked dry bean (Phaseolus vulgaris L.) cultivars representing three market classes (black, dark red kidney and pinto) grown in 2005 were isolated with headspace solid phase microextraction (HS-SPME), and analyzed with gas chromatography mass spectrometry (GC-MS). A total of 62 volatiles consisting of aromatic hydrocarbons, aldehydes, alkanes, alcohols and ketones represented on average 62, 38, 21, 12, and 9 x 10(6) total area counts, respectively. Bean cultivars differed in abundance and profile of volatiles. The combination of 18 compounds comprising a common profile explained 79% of the variance among cultivars based on principal component analysis (PCA). The SPME technique proved to be a rapid and effective method for routine evaluation of dry bean volatile profile.

  13. Gas-Purged Headspace Liquid Phase Microextraction System for Determination of Volatile and Semivolatile Analytes

    PubMed Central

    Zhang, Meihua; Bi, Jinhu; Yang, Cui; Li, Donghao; Piao, Xiangfan

    2012-01-01

    In order to achieve rapid, automatic, and efficient extraction for trace chemicals from samples, a system of gas-purged headspace liquid phase microextraction (GP-HS-LPME) has been researched and developed based on the original HS-LPME technique. In this system, semiconductor condenser and heater, whose refrigerating and heating temperatures were controlled by microcontroller, were designed to cool the extraction solvent and to heat the sample, respectively. Besides, inert gas, whose gas flow rate was adjusted by mass flow controller, was continuously introduced into and discharged from the system. Under optimized parameters, extraction experiments were performed, respectively, using GP-HS-LPME system and original HS-LPME technique for enriching volatile and semivolatile target compounds from the same kind of sample of 15 PAHs standard mixture. GC-MS analysis results for the two experiments indicated that a higher enrichment factor was obtained from GP-HS-LPME. The enrichment results demonstrate that GP-HS-LPME system is potential in determination of volatile and semivolatile analytes from various kinds of samples. PMID:22448341

  14. Ultrafast Screening and Quantitation of Pesticides in Food and Environmental Matrices by Solid-Phase Microextraction-Transmission Mode (SPME-TM) and Direct Analysis in Real Time (DART).

    PubMed

    Gómez-Ríos, Germán Augusto; Gionfriddo, Emanuela; Poole, Justen; Pawliszyn, Janusz

    2017-07-05

    The direct interface of microextraction technologies to mass spectrometry (MS) has unquestionably revolutionized the speed and efficacy at which complex matrices are analyzed. Solid Phase Micro Extraction-Transmission Mode (SPME-TM) is a technology conceived as an effective synergy between sample preparation and ambient ionization. Succinctly, the device consists of a mesh coated with polymeric particles that extracts analytes of interest present in a given sample matrix. This coated mesh acts as a transmission-mode substrate for Direct Analysis in Real Time (DART), allowing for rapid and efficient thermal desorption/ionization of analytes previously concentrated on the coating, and dramatically lowering the limits of detection attained by sole DART analysis. In this study, we present SPME-TM as a novel tool for the ultrafast enrichment of pesticides present in food and environmental matrices and their quantitative determination by MS via DART ionization. Limits of quantitation in the subnanogram per milliliter range can be attained, while total analysis time does not exceed 2 min per sample. In addition to target information obtained via tandem MS, retrospective studies of the same sample via high-resolution mass spectrometry (HRMS) were accomplished by thermally desorbing a different segment of the microextraction device.

  15. One-calibrant kinetic calibration for on-site water sampling with solid-phase microextraction.

    PubMed

    Ouyang, Gangfeng; Cui, Shufen; Qin, Zhipei; Pawliszyn, Janusz

    2009-07-15

    The existing solid-phase microextraction (SPME) kinetic calibration technique, using the desorption of the preloaded standards to calibrate the extraction of the analytes, requires that the physicochemical properties of the standard should be similar to those of the analyte, which limited the application of the technique. In this study, a new method, termed the one-calibrant kinetic calibration technique, which can use the desorption of a single standard to calibrate all extracted analytes, was proposed. The theoretical considerations were validated by passive water sampling in laboratory and rapid water sampling in the field. To mimic the variety of the environment, such as temperature, turbulence, and the concentration of the analytes, the flow-through system for the generation of standard aqueous polycyclic aromatic hydrocarbons (PAHs) solution was modified. The experimental results of the passive samplings in the flow-through system illustrated that the effect of the environmental variables was successfully compensated with the kinetic calibration technique, and all extracted analytes can be calibrated through the desorption of a single calibrant. On-site water sampling with rotated SPME fibers also illustrated the feasibility of the new technique for rapid on-site sampling of hydrophobic organic pollutants in water. This technique will accelerate the application of the kinetic calibration method and also will be useful for other microextraction techniques.

  16. Highly sensitive and selective hyphenated technique (molecularly imprinted polymer solid-phase microextraction-molecularly imprinted polymer sensor) for ultra trace analysis of aspartic acid enantiomers.

    PubMed

    Prasad, Bhim Bali; Srivastava, Amrita; Tiwari, Mahavir Prasad

    2013-03-29

    The present work is related to combination of molecularly imprinted solid-phase microextraction and complementary molecularly imprinted polymer-sensor. The molecularly imprinted polymer grafted on titanium dioxide modified silica fiber was used for microextraction, while the same polymer immobilized on multiwalled carbon nanotubes/titanium dioxide modified pencil graphite electrode served as a detection tool. In both cases, the surface initiated polymerization was found to be advantageous to obtain a nanometer thin imprinted film. The modified silica fiber exhibited high adsorption capacity and enantioselective diffusion of aspartic acid isomers into respective molecular cavities. This combination enabled double preconcentrations of d- and l-aspartic acid that helped sensing both isomers in real samples, without any cross-selectivity and matrix complications. Taking into account 6×10(4)-fold dilution of serum and 2×10(3)-fold dilution of cerebrospinal fluid required by the proposed method, the limit of detection for l-aspartic acid is 0.031ngmL(-1). Also, taking into account 50-fold dilution required by the proposed method, the limit of detection for d-aspartic acid is 0.031ngmL(-1) in cerebrospinal fluid. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Solventless and solvent-minimized sample preparation techniques for determining currently used pesticides in water samples: a review.

    PubMed

    Tankiewicz, Maciej; Fenik, Jolanta; Biziuk, Marek

    2011-10-30

    The intensification of agriculture means that increasing amounts of toxic organic and inorganic compounds are entering the environment. The pesticides generally applied nowadays are regarded as some of the most dangerous contaminants of the environment. Their presence in the environment, especially in water, is hazardous because they cause human beings to become more susceptible to disease. For these reasons, it is essential to monitor pesticide residues in the environment with the aid of all accessible analytical methods. The analysis of samples for the presence of pesticides is problematic, because of the laborious and time-consuming operations involved in preparing samples for analysis, which themselves may be a source of additional contaminations and errors. To date, it has been standard practice to use large quantities of organic solvents in the sample preparation process; but as these solvents are themselves hazardous, solventless and solvent-minimized techniques are coming into use. This paper discusses the most commonly used over the last 15 years sample preparation techniques for monitoring organophosphorus and organonitrogen pesticides residue in water samples. Furthermore, a significant trend in sample preparation, in accordance with the principles of 'Green Chemistry' is the simplification, miniaturization and automation of analytical techniques. In view of this aspect, several novel techniques are being developed in order to reduce the analysis step, increase the sample throughput and to improve the quality and the sensitivity of analytical methods. The paper describes extraction techniques requiring the use of solvents - liquid-liquid extraction (LLE) and its modifications, membrane extraction techniques, hollow fibre-protected two-phase solvent microextraction, liquid phase microextraction based on the solidification of a floating organic drop (LPME-SFO), solid-phase extraction (SPE) and single-drop microextraction (SDME) - as well as solvent-free techniques - solid phase microextraction (SPME) and stir bar sorptive extraction (SBSE). The advantages and drawbacks of these techniques are also discussed, and some solutions to their limitations are proposed. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Development of new solid-phase microextraction fibers by sol-gel technology for the determination of organophosphorus pesticide multiresidues in food.

    PubMed

    Yu, Jianxin; Wu, Caiying; Xing, Jun

    2004-05-21

    Allyloxy bisbenzo 16-crown-5 trimethoxysilane was first used as precursor to prepare the sol-gel-derived bisbenzo crown ether/hydroxyl-terminated silicone oil (OH-TSO) SPME coating. The coating procedure involving sol solution composition and conditioning process was presented. Compared with commercial SPME stationary phases, the new coatings showed higher extraction efficiency and therefore could provide higher sensitivity for organphosphorous pesticides (OPs). Limits of detection (LODs) were in the range of 0.003-1.0 ng/g for these OPs in food samples (honey, juice, orange and pakchoi). The optimal extraction conditions of the new coatings to OPs in these samples were investigated by adjusting extraction time, salt addition, extraction temperature, and dilution ratios of samples with distilled water by using SPME coupled with gas chromatography (GC)-flame photometric detection (FPD). The method was applied to determine the concentrations of OPs in real samples.

  19. On-line packed magnetic in-tube solid phase microextraction of acidic drugs such as naproxen and indomethacin by using Fe3O4@SiO2@layered double hydroxide nanoparticles with high anion exchange capacity.

    PubMed

    Shamsayei, Maryam; Yamini, Yadollah; Asiabi, Hamid; Safari, Meysam

    2018-02-22

    The authors describe a 3-component nanoparticle system composed of a silica-coated magnetite (Fe 3 O 4 ) core and a layered double (Cu-Cr) hydroxide nanoplatelet shell. The sorbent has a high anion exchange capacity for extraction anionic species. A simple online system, referred to as "on-line packed magnetic-in-tube solid phase microextraction" was designed. The nanoparticles were placed in a stainless steel cartridge via dry packing. The cartridge was then applied to the preconcentration acidic drugs including naproxen and indomethacin from urine and plasma. Extraction and desorption times, pH values of the sample solution and flow rates of sample solution and eluent were optimized. Analytes were then quantified by HPLC with UV detection. Under optimal conditions, the limits of detection range from 70 to 800 ng L -1 , with linear responses from 0.1-500 μg L -1 (water samples), 0.6-500 μg L -1 (spiked urine), and 0.9-500 μg L -1 (spiked plasma). The inter- and intra-assay precisions (RSDs, for n = 5) are in the range of 2.2-5.4%, 2.8-4.9%, and 2.0-5.2% at concentration levels of 5, 25 and 50 μg L -1 , respectively. The method was applied to the analysis of the drugs in spiked human urine and plasma, and good results were achieved. Graphical abstract Fe 3 O 4 @SiO 2 @CuCr-LDH magnetic nanoparticles were synthesized and packed in to a stainless steel column. The column was applied to solid phase microextraction of acidic drugs from biological samples.

  20. Solid-phase extraction in combination with dispersive liquid-liquid microextraction and ultra-high performance liquid chromatography-tandem mass spectrometry analysis: the ultra-trace determination of 10 antibiotics in water samples.

    PubMed

    Liang, Ning; Huang, Peiting; Hou, Xiaohong; Li, Zhen; Tao, Lei; Zhao, Longshan

    2016-02-01

    A novel method, solid-phase extraction combined with dispersive liquid-liquid microextraction (SPE-DLLME), was developed for ultra-preconcentration of 10 antibiotics in different environmental water samples prior to ultra-high performance liquid chromatography-tandem mass spectrometry detection. The optimized results were obtained as follows: after being adjusted to pH 4.0, the water sample was firstly passed through PEP-2 column at 10 mL min(-1), and then methanol was used to elute the target analytes for the following steps. Dichloromethane was selected as extraction solvent, and methanol/acetonitrile (1:1, v/v) as dispersive solvent. Under optimal conditions, the calibration curves were linear in the range of 1-1000 ng mL(-1) (sulfamethoxazole, cefuroxime axetil), 5-1000 ng mL(-1) (tinidazole), 10-1000 ng mL(-1) (chloramphenicol), 2-1000 ng mL(-1) (levofloxacin oxytetracycline, doxycycline, tetracycline, and ciprofloxacin) and 1-400 ng mL(-1) (sulfadiazine) with a good precision. The LOD and LOQ of the method were at very low levels, below 1.67 and 5.57 ng mL(-1), respectively. The relative recoveries of the target analytes were in the range from 64.16% to 99.80% with relative standard deviations between 0.7 and 8.4%. The matrix effect of this method showed a great decrease compared with solid-phase extraction and a significant value of enrichment factor (EF) compared with dispersive liquid-liquid microextraction. The developed method was successfully applied to the extraction and analysis of antibiotics in different water samples with satisfactory results.

  1. Solid phase microextraction of diclofenac using molecularly imprinted polymer sorbent in hollow fiber combined with fiber optic-linear array spectrophotometry.

    PubMed

    Pebdani, Arezou Amiri; Shabani, Ali Mohammad Haji; Dadfarnia, Shayessteh; Khodadoust, Saeid

    2015-08-05

    A simple solid phase microextraction method based on molecularly imprinted polymer sorbent in the hollow fiber (MIP-HF-SPME) combined with fiber optic-linear array spectrophotometer has been applied for the extraction and determination of diclofenac in environmental and biological samples. The effects of different parameters such as pH, times of extraction, type and volume of the organic solvent, stirring rate and donor phase volume on the extraction efficiency of the diclofenac were investigated and optimized. Under the optimal conditions, the calibration graph was linear (r(2)=0.998) in the range of 3.0-85.0 μg L(-1) with a detection limit of 0.7 μg L(-1) for preconcentration of 25.0 mL of the sample and the relative standard deviation (n=6) less than 5%. This method was applied successfully for the extraction and determination of diclofenac in different matrices (water, urine and plasma) and accuracy was examined through the recovery experiments. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Determination of nitrate esters in water samples Comparison of efficiency of solid-phase extraction and solid-phase microextraction.

    PubMed

    Jezová, Vera; Skládal, Jan; Eisner, Ales; Bajerová, Petra; Ventura, Karel

    2007-12-07

    This paper deals with comparison of efficiency of extraction techniques (solid-phase extraction, SPE and solid-phase microextraction, SPME) used for extraction of nitrate esters (ethyleneglycoldinitrate, EGDN and nitroglycerin, NG), representing the first step of the method of quantitative determination of trace concentrations of nitrate esters in water samples. EGDN and NG are subsequently determined by means of high-performance liquid chromatography with ultraviolet detection (HPLC-UV). Optimization of SPE and SPME conditions was carried out using model water samples. Seven SPE cartridges were tested and the conditions were optimized (type of sorbent, type and volume of solvent to be used as eluent). For both nitrate esters the limit of detection (LOD) and the limit of quantification (LOQ) obtained using SPE/HPLC-UV were 0.23 microg mL(-1) and 0.70 microg mL(-1), respectively. Optimization of SPME conditions: type of SPME fibre (four fibres were tested), type and time of sorption/desorption, temperature of sorption. PDMS/DVB (polydimethylsiloxane/divinylbenzene) fibre coating proved to be suitable for extraction of EGDN and NG. For this fibre the LOD and the LOQ for both nitrate esters were 0.16 microg mL(-1) and 0.50 microg mL(-1), respectively. Optimized methods SPE/HPLC-UV and SPME/HPLC-UV were then used for quantitative determination of nitrate esters content in real water samples from the production of EGDN and NG.

  3. On-line solid-phase microextraction of triclosan, bisphenol A, chlorophenols, and selected pharmaceuticals in environmental water samples by high-performance liquid chromatography-ultraviolet detection.

    PubMed

    Kim, Dalho; Han, Jungho; Choi, Yongwook

    2013-01-01

    A method using on-line solid-phase microextraction (SPME) on a carbowax-templated fiber followed by liquid chromatography (LC) with ultraviolet (UV) detection was developed for the determination of triclosan in environmental water samples. Along with triclosan, other selected phenolic compounds, bisphenol A, and acidic pharmaceuticals were studied. Previous SPME/LC or stir-bar sorptive extraction/LC-UV for polar analytes showed lack of sensitivity. In this study, the calculated octanol-water distribution coefficient (log D) values of the target analytes at different pH values were used to estimate polarity of the analytes. The lack of sensitivity observed in earlier studies is identified as a lack of desorption by strong polar-polar interactions between analyte and solid-phase. Calculated log D values were useful to understand or predict the interaction between analyte and solid phase. Under the optimized conditions, the method detection limit of selected analytes by using on-line SPME-LC-UV method ranged from 5 to 33 ng L(-1), except for very polar 3-chlorophenol and 2,4-dichlorophenol which was obscured in wastewater samples by an interfering substance. This level of detection represented a remarkable improvement over the conventional existing methods. The on-line SPME-LC-UV method, which did not require derivatization of analytes, was applied to the determination of TCS including phenolic compounds and acidic pharmaceuticals in tap water and river water and municipal wastewater samples.

  4. Quantitative fingerprinting by headspace--two-dimensional comprehensive gas chromatography-mass spectrometry of solid matrices: some challenging aspects of the exhaustive assessment of food volatiles.

    PubMed

    Nicolotti, Luca; Cordero, Chiara; Cagliero, Cecilia; Liberto, Erica; Sgorbini, Barbara; Rubiolo, Patrizia; Bicchi, Carlo

    2013-10-10

    The study proposes an investigation strategy that simultaneously provides detailed profiling and quantitative fingerprinting of food volatiles, through a "comprehensive" analytical platform that includes sample preparation by Headspace Solid Phase Microextraction (HS-SPME), separation by two-dimensional comprehensive gas chromatography coupled with mass spectrometry detection (GC×GC-MS) and data processing using advanced fingerprinting approaches. Experiments were carried out on roasted hazelnuts and on Gianduja pastes (sugar, vegetable oil, hazelnuts, cocoa, nonfat dried milk, vanilla flavorings) and demonstrated that the information potential of each analysis can better be exploited if suitable quantitation methods are applied. Quantitation approaches through Multiple Headspace Extraction and Standard Addition were compared in terms of performance parameters (linearity, precision, accuracy, Limit of Detection and Limit of Quantitation) under headspace linearity conditions. The results on 19 key analytes, potent odorants, and technological markers, and more than 300 fingerprint components, were used for further processing to obtain information concerning the effect of the matrix on volatile release, and to produce an informative chemical blueprint for use in sensomics and flavoromics. The importance of quantitation approaches in headspace analysis of solid matrices of complex composition, and the advantages of MHE, are also critically discussed. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Comparing the Accumulation of PCBs by Passive Samplers and Mussels from the Water Column at a Contaminated Sediment Site

    EPA Science Inventory

    Passive samplers, including semi-permeable membrane devices (SPMDs), solid phase microextraction (SPME) and polyethylene devices (PEDs), provide innovative tools for measuring hydrophobic organic contaminants (HOCs) originating from contaminated waters and sediments. Because the...

  6. Solid-phase microextraction of methadone in urine samples by electrochemically co-deposited sol-gel/Cu nanocomposite fiber.

    PubMed

    Mohammadiazar, Sirwan; Hasanli, Fateme; Maham, Mehdi; Payami Samarin, Somayeh

    2017-08-01

    Electrochemically co-deposited sol-gel/Cu nanocomposites have been introduced as a novel, simple and single-step technique for preparation of solid-phase microextraction (SPME) coating to extract methadone (MDN) (a synthetic opioid) in urine samples. The porous surface structure of the sol-gel/Cu nanocomposite coating was revealed by scanning electron microscopy. Direct immersion SPME followed by HPLC-UV determination was employed. The factors influencing the SPME procedure, such as the salt content, desorption solvent type, pH and equilibration time, were optimized. The best conditions were obtained with no salt content, acetonitrile as desorption solvent type, pH 9 and 10 min equilibration time. The calibration graphs for urine samples showed good linearity. The detection limit was about 0.2 ng mL -1 . Also, the novel method for preparation of nanocomposite fiber was compared with previously reported techniques for MDN determination. The results show that the novel nanocomposite fiber has relatively high extraction efficiency. Copyright © 2016 John Wiley & Sons, Ltd.

  7. Highly porous solid-phase microextraction fiber coating based on poly(ethylene glycol)-modified ormosils synthesized by sol-gel technology.

    PubMed

    da Costa Silva, Raquel Gomes; Augusto, Fabio

    2005-04-22

    The preparation and characteristics of solid-phase microextraction (SPME) fibers coated with Carbowax 20M ormosil (organically modified silica) are described here. Raw fused silica fibers were coated with Carbowax 20M-modified silica using sol-gel process. Scanning electron micrographs of fibers revealed a highly porous, sponge-like coating with an average thickness of (8 +/- 1) microm. The sol-gel Carbowax fibers were compared to commercial fibers coated with 100 microm polydimethylsiloxane (PDMS) and 65 microm Carbowax-divinylbenzene (DVB). Shorter equilibrium times were possible with the sol-gel Carbowax fiber: for headspace extraction of the test analytes, they ranged from less than 3 min for benzene to 15 min for o-xylene. Extraction efficiencies of the sol-gel Carbowax fiber were superior to those of conventional fibers: for o-xylene, the extracted masses were 230 and 540% of that obtained with 100 microm PDMS and 65 microm Carbowax-DVB fibers, respectively.

  8. [The progress in speciation analysis of trace elements by atomic spectrometry].

    PubMed

    Wang, Zeng-Huan; Wang, Xu-Nuo; Ke, Chang-Liang; Lin, Qin

    2013-12-01

    The main purpose of the present work is to review the different non-chromatographic methods for the speciation analysis of trace elements in geological, environmental, biological and medical areas. In this paper, the sample processing methods in speciation analysis were summarized, and the main strategies for non-chromatographic technique were evaluated. The basic principles of the liquid extractions proposed in the published literatures recently and their advantages and disadvantages were discussed, such as conventional solvent extraction, cloud point extraction, single droplet microextraction, and dispersive liquid-liquid microextraction. Solid phase extraction, as a non-chromatographic technique for speciation analysis, can be used in batch or in flow detection, and especially suitable for the online connection to atomic spectrometric detector. The developments and applications of sorbent materials filled in the columns of solid phase extraction were reviewed. The sorbents include chelating resins, nanometer materials, molecular and ion imprinted materials, and bio-sorbents. Other techniques, e. g. hydride generation technique and coprecipitation, were also reviewed together with their main applications.

  9. Application of solid-phase microextraction in the investigation of protein binding of pharmaceuticals.

    PubMed

    Theodoridis, Georgios

    2006-01-18

    Protein-drug interactions of seven common pharmaceuticals were studied using solid-phase microextraction (SPME). SPME can be used in such investigations on the condition that no analyte depletion occurs. In multi-compartment systems (e.g. a proteinaceous matrix) only the free portion of the analyte is able to partition into the SPME fiber. In addition if no sample depletion occurs, the bound drug-free drug equilibria are not disturbed. In the present study seven pharmaceuticals (quinine, quinidine, naproxen, ciprofloxacin, haloperidol, paclitaxel and nortriptyline) were assayed by SPME. For quantitative purposes SPME was validated first in the absence of proteins. Calibration curves were constructed for each drug by HPLC-fluorescence and HPLC-UV analysis. SPME was combined to HPLC off-line, desorption occurring in HPLC inserts filled with 200 microL methanol. Binding of each drug to human serum albumin was studied independently. Experimental results were in agreement with literature data and ultrafiltration experiments, indicating the feasibility of the method for such bioanalytical purposes.

  10. Capillary liquid chromatographic analysis of fat-soluble vitamins and beta-carotene in combination with in-tube solid-phase microextraction.

    PubMed

    Xu, Hui; Jia, Li

    2009-01-01

    A capillary liquid chromatography (CLC) system with UV/vis detection was coupled with an in-tube solid-phase microextraction (SPME) device for the analysis of fat-soluble vitamins and beta-carotene. A monolithic silica-ODS column was used as the extraction medium. An optical-fiber flow cell with a long light path in the UV/vis detector was utilized to further enhance the detection sensitivity. In the in-tube SPME/CLC system, the pre-condition of the extraction column and the effect of the injection volume were investigated. The detection limits (LOD) for the fat-soluble vitamins and beta-carotene were in the range from 1.9 to 173 ng/mL based on the signal-to-noise ratio of 3 (S/N=3). The relative standard deviations of migration time and peak area for each analyte were less than 5.0%. The method was applied to the analysis of fat-soluble vitamins and beta-carotene contents in corns.

  11. [Preparation of a novel activated carbon coating fiber for solid phase micro-extraction and its application for halocarbon compound analysis in water].

    PubMed

    Wang, Shutao; Wang, Yan; You, Hong; Liang, Zhihua

    2004-09-01

    A novel activated carbon coating fiber used for solid phase micro-extraction (SPME) was prepared using activated carbon powder and silica resin adhesive. The extraction properties of the novel activated carbon coating fiber were investigated. The results indicate that this coating fiber has high concentration ability, with enrichment factors for chloroform, carbon tetrachloride, trichloroethylene and tetrachloroethylene in the range of 13.8 to 18.7. The fiber is stable at temperature as high as 290 degrees C and it can be used for over 140 times at 250 degrees C. The activated carbon coating fiber was then applied to the analysis of the four halocarbon compounds mentioned above. A linear correlation with correlation coefficients between 0.995 2 and 0.999 4 and the detection limits between 0.008 and 0.05 microg/L were observed. The method was also applied to a real water sample analysis and the recoveries of these halocarbon compounds were from 95.5% to 104.6%.

  12. Non-conventional solvents in liquid phase microextraction and aqueous biphasic systems.

    PubMed

    An, Jiwoo; Trujillo-Rodríguez, María J; Pino, Verónica; Anderson, Jared L

    2017-06-02

    The development of rapid, convenient, and high throughput sample preparation approaches such as liquid phase microextraction techniques have been continuously developed over the last decade. More recently, significant attention has been given to the replacement of conventional organic solvents used in liquid phase microextraction techniques in order to reduce toxic waste and to improve selectivity and/or extraction efficiency. With these objectives, non-conventional solvents have been explored in liquid phase microextraction and aqueous biphasic systems. The utilized non-conventional solvents include ionic liquids, magnetic ionic liquids, and deep eutectic solvents. They have been widely used as extraction solvents or additives in various liquid phase microextraction modes including dispersive liquid-liquid microextraction, single-drop microextraction, hollow fiber-liquid phase microextraction, as well as in aqueous biphasic systems. This review provides an overview into the use of non-conventional solvents in these microextraction techniques in the past 5 years (2012-2016). Analytical applications of the techniques are also discussed. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Static headspace analysis using polyurethane phases--application to roasted coffee volatiles characterization.

    PubMed

    Rodrigues, C; Portugal, F C M; Nogueira, J M F

    2012-01-30

    Static headspace sorptive extraction using polyurethane foams (HSSE(PU)) followed by gas chromatography coupled to mass spectrometry is proposed for volatile analysis. The application of this novel analytical approach to characterize the volatiles profile from roasted coffee samples, selected as model system, revealed remarkable advantages under convenient experimental conditions. The comparison of HSSE(PU) with other well-established procedures, such as headspace sorptive extraction using polydimethylsiloxane (HSSE(PDMS)) and headspace solid phase microextraction using carboxen/polydimethylsiloxane fibers (HS-SPME(CAR/PDMS)), showed that the former presented much higher capacity, sensitivity and even selectivity, where larger abundance and number of roasted coffee volatile compounds (e.g. furans, pyrazines, ketones, acids and pyrroles) could be achieved, under similar experimental conditions. The data presented herein proved, for the first time, that PU foams present great performance for static headspace sorption-based procedures, showing to be an alternative polymeric phase for volatile analysis. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Porous Aromatic Framework 48/Gel Hybrid Material Coated Solid-Phase Microextraction Fiber for the Determination of the Migration of Styrene from Polystyrene Food Contact Materials.

    PubMed

    Jin, Yuanyuan; Li, Zhongyue; Yang, Lei; Xu, Jun; Zhao, Le; Li, Zhonghao; Niu, Jiajia

    2017-01-17

    A novel solid-phase microextraction (SPME) fiber was fabricated by a porous aromatic framework 48 (PAF-48)/gel hybrid material through a sol-gel process. PAF-48 is a porous organic framework (POF) material that was polymerized from 1,3,5-triphenylbenzene. The uniform pore structure, high surface area, continuous conjugate network, and hydrophobicity make PAF-48 expected to have special abilities to absorb and extract styrene as well as some other harmful volatile aromatic compounds (VACs). The PAF-48/gel-coated fiber was explored for the extraction of styrene and six VACs (benzene, toluene, ethylbenzene, and xylenes) from aqueous food simulants followed by gas chromatography (GC) separation. The fiber was found to be very sensitive for the determination of the target molecules with wide linear ranges (0.1-200 or 500 μg·kg -1 ), low limits of detection (LODs, 0.003-0.060 μg·kg -1 ), acceptable precisions (intraday relative standard deviation, RSD < 5.9%, interday RSD < 7.3%), and long lifetime (>200 times). Particularly for styrene, the PAF-48/gel-coated fiber exhibited a much lower LOD (0.006 μg·kg -1 ) compared with most of the reported fibers. Moreover, the PAF-48/gel-coated fiber had a high extraction selectivity for styrene and VACs over alcohols, phenols, aromatic amines, and alkanes and show a molecular sieving effect for the different molecule sizes. Finally, the PAF-48/gel-coated SPME fiber was successfully applied in GC for the determination of the specific migrations of styrene and VACs from polystyrene (PS) plastic food contact materials (FCMs).

  15. Compound-specific nitrogen and carbon isotope analysis of nitroaromatic compounds in aqueous samples using solid-phase microextraction coupled to GC/IRMS.

    PubMed

    Berg, Michael; Bolotin, Jakov; Hofstetter, Thomas B

    2007-03-15

    Solid-phase microextraction (SPME) coupled to gas chromatography/isotope ratio mass spectrometry was used to determine the delta15N and delta13C signatures of selected nitroaromatic contaminants such as the explosive 2,4,6-trinitrotoluene (TNT) for derivation of isotopic enrichment factors of contaminant transformation. Parameters for efficient extraction of nitroaromatic compounds (NACs) and substituted anilines from water samples were evaluated by SPME-GC/MS. delta13C signatures determined by SPME-GC/IRMS and elemental analyzer IRMS (EA-IRMS) were in good agreement, generally within +/-0.7 per thousand, except for 2,4-dinitrotoluene (2,4-DNT) and TNT, which showed slight deviations (<1.3 per thousand). Limits of detection (LODs) for delta13C analysis by SPME-GC/IRMS were between 73 and 780 microg L-1 and correlated with the extraction efficiencies of the compounds determined by SPME-GC/MS. Nitrogen isotope measurements by SPME-GC/IRMS were of similar precision (standard deviations <0.8 per thousand) for all NACs except for TNT. delta15N signatures matched the reference values obtained by EA-IRMS within +/-1.3 per thousand (+2.5 per thousand for TNT), but no systematic trend was found for the deviations. LODs of delta15N measurements ranged from 1.6 to 9.6 mg L-1 for nitrotoluenes, chlorinated NACs and DNTs (22 mg L-1 for TNT). The SPME-GC/IRMS method is well suited for the determination of isotopic enrichment factors of various NAC transformation processes and provides so far unexplored possibilities to elucidate behavior and degradation mechanisms of nitroaromatic contaminants in soils and groundwaters.

  16. A solid-phase microextraction fiber with carbon nanoparticles as sorbent material prepared by a simple flame-based preparation process.

    PubMed

    Sun, Min; Feng, Juanjuan; Qiu, Huamin; Fan, Lulu; Li, Leilei; Luo, Chuannan

    2013-07-26

    A novel carbon nanoparticles-coated solid-phase microextraction (SPME) fiber was prepared via a simple and low-cost flame-based preparation process, with stainless steel wire as support. Surface characteristic of the fiber was studied with scanning electron microscope. A nano-scaled brushy structure was observed. Coupled to gas chromatography (GC), the fiber was used to extract phthalate esters (PAEs) and polycyclic aromatic hydrocarbons (PAHs) in aqueous samples. Analytical performances of the proposed method were investigated under the optimum extraction conditions (extraction temperature, 40°C; content of KCl, 30% (w/v); extraction time, 50min for PAEs and 40min for PAHs) and compared with other reports for the same analytes. Calibration ranges were 0.06-500μgL(-1) for di-n-butyl phthalate (DBP), and 0.1-300μgL(-1) for di-cyclohexyl phthalate (DCHP) and di-(2-ethyl-hexyl) phthalate (DEHP). For the eight PAHs, good linearity was obtained ranging from 0.01 to 150μgL(-1). Limits of detection were 0.005μgL(-1) for three PAEs and 0.001-0.003μgL(-1) for eight PAHs. The fiber exhibited excellent stability. It can be used for 100 times with RSDs of extraction efficiency less than 22.4%. The as-established SPME-GC method was applied to determine PAEs in food-wrap and PAHs in cigarette ash and snow water, and satisfactory results were obtained. The carbon nanoparticles-coated SPME fiber was efficient for sampling of organic compounds from aqueous samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Evaluation of volatile metabolites as markers in Lycopersicon esculentum L. cultivars discrimination by multivariate analysis of headspace solid phase microextraction and mass spectrometry data.

    PubMed

    Figueira, José; Câmara, Hugo; Pereira, Jorge; Câmara, José S

    2014-02-15

    To gain insights on the effects of cultivar on the volatile metabolomic expression of different tomato (Lycopersicon esculentum L.) cultivars--Plum, Campari, Grape, Cherry and Regional, cultivated under similar edafoclimatic conditions, and to identify the most discriminate volatile marker metabolites related to the cultivar, the chromatographic profiles resulting from headspace solid phase microextraction (HS-SPME) and gas chromatography-mass spectrometry (GC-qMS) analysis, combined with multivariate analysis were investigated. The data set composed by the 77 volatile metabolites identified in the target tomato cultivars, 5 of which (2,2,6-trimethylcyclohexanone, 2-methyl-6-methyleneoctan-2-ol, 4-octadecyl-morpholine, (Z)-methyl-3-hexenoate and 3-octanone) are reported for the first time in tomato volatile metabolomic composition, was evaluated by chemometrics. Firstly, principal component analysis was carried out in order to visualise data trends and clusters, and then, linear discriminant analysis in order to detect the set of volatile metabolites able to differentiate groups according to tomato cultivars. The results obtained revealed a perfect discrimination between the different Lycopersicon esculentum L. cultivars considered. The assignment success rate was 100% in classification and 80% in prediction ability by using "leave-one-out" cross-validation procedure. The volatile profile was able to differentiate all five cultivars and revealed complex interactions between them including the participation in the same biosynthetic pathway. The volatile metabolomic platform for tomato samples obtained by HS-SPME/GC-qMS here described, and the interrelationship detected among the volatile metabolites can be used as a roadmap for biotechnological applications, namely to improve tomato aroma and their acceptance in the final consumer, and for traceability studies. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Development of magnetic dispersive solid phase extraction using toner powder as an efficient and economic sorbent in combination with dispersive liquid-liquid microextraction for extraction of some widely used pesticides in fruit juices.

    PubMed

    Farajzadeh, Mir Ali; Mohebbi, Ali

    2018-01-12

    In this study, for the first time, a magnetic dispersive solid phase extraction method using an easy-accessible, cheap, and efficient magnetic sorbent (toner powder) combined with dispersive liquid-liquid microextraction has been developed for the extraction and preconcentration of some widely used pesticides (diazinon, ametryn, chlorpyrifos, penconazole, oxadiazon, diniconazole, and fenazaquin) from fruit juices prior to their determination by gas chromatography-flame ionization detection. In this method, the magnetic sorbent is mixed with an appropriate dispersive solvent (methanol-water, 80:20, v/v) and then injected into an aqueous sample containing the analytes. By this action the analytes are rapidly adsorbed on the sorbent by binding to its carbon. The sorbent particles are isolated from the aqueous solution in the presence of an external magnetic field. Then an appropriate organic solvent (acetone) is used to desorb the analytes from the sorbent. Finally, the obtained supernatant is mixed with an extraction solvent and injected into deionized water in order to achieve high enrichment factors and sensitivity. Several significant factors affecting the performance of the introduced method were investigated and optimized. Under the optimum experimental conditions, the extraction recoveries of the proposed method for the selected analytes ranged from 49-75%. The relative standard deviations were ≤7% for intra- (n = 6) and inter-day (n = 4) precisions at a concentration of 10 μg L -1 of each analyte. The limits of detection were in the range of 0.15-0.36 μg L -1 . Finally, the applicability of the proposed method was evaluated by analysis of the selected analytes in some fruit juices. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. A salting out system for improving the efficiency of the headspace solid-phase microextraction of short and medium chain free fatty acids.

    PubMed

    Fiorini, Dennis; Pacetti, Deborah; Gabbianelli, Rosita; Gabrielli, Serena; Ballini, Roberto

    2015-08-28

    Given the importance of short and medium chain free fatty acids (FFAs) in several fields, this study sought to improve the extraction efficiency of the solid-phase microextraction (SPME) of FFAs by evaluating salting out agents that appear promising for this application. The salts ammonium sulfate ((NH4)2SO4) and sodium dihydrogen phosphate (NaH2PO4) were tried on their own and in combination (3.7/1), in four different total amounts, as salting out agents in the headspace-SPME-gas chromatographic (HS-SPME-GC) analysis of the FFAs from acetic acid (C2) to decanoic acid (C10). Their performance in a model system of an aqueous standard mixture of FFAs at a pH of 3.5 was compared to that of the more commonly used sodium chloride (NaCl) and sodium sulfate (Na2SO4). All of the salts and salt systems evaluated, in proper amount, gave improved results compared to NaCl (saturated), which instead gave interesting results only for the least volatile FFAs C8 and C10. For C2-C6, the salt system that gave the best results compared to NaCl was (NH4)2SO4/NaH2PO4, in the highest of the four amounts evaluated, with factor increases between 1.2 and 4.1-fold, and NaH2PO4, between 1.0 and 4.3-fold. The SPME extraction efficiency given by the mixture (NH4)2SO4/NaH2PO4 was also assessed on biological and food samples, confirming that overall it performed better than NaCl. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. [Determination of ten photoinitiators in fruit juices and tea beverages by solid-phase micro-extraction coupled with gas chromatography/mass spectrometry].

    PubMed

    Liu, Pengyan; Chen, Yanjie; Zhao, Chunxia; Tian, Lei

    2013-12-01

    A method for the determination of ten photoinitiators (PIs), benzophenone, ethyl 4-dimethylaminobenzoate, 1-hydroxycyclohexyl-phenylketone, 4-methylbenzophenone, 2-ethylhexyl-4-dimethylaminobenzoate, 4-chlorobenzophenone, 2-chlorothioxanthone, 2-isopropylthio-xanthone, 2,2-dimethoxy-2-phenylacetophenone, methyl 2-benzoylbenzoate, in 13 kinds of fruit juice and 3 kinds of tea beverage has been established, using solid-phase micro-extraction (SPME) combined with chromatography/mass spectrometry (GC/MS). At first, the major factors of SPME, extraction time and temperature, were studied through orthogonal experiment. Then the optimal operation conditions were obtained via the refinement of various factors. After the sample was extracted by SPME, it was desorbed for target analytes in sampling inlet for 3 min, and separated on an HP-5MS column, then detected by MS in selected ion monitoring mode, and quantified through calibration curve. The working curves were obtained using sample matrix in order to eliminate the matrix interference. The linear range was from 0.3 microg/L to 60 microg/L and the detection limit range was from 3 ng/L to 16 ng/L. The samples were determined five times with four different spiked levels individually and the relative standard deviations of all the samples were less than 14.5%. This determination method was applied in 16 kinds of packed beverages with different brands and different species. Benzophenone had been detected from all the samples. 4-Methylbenzophenone, 2-ethylhexyl-4-dimethylaminobenzoate, 2-isopropylthioxanthone, 1-hydroxycyclohexyl-phenylketone and 2-chlorothioxanthone had been detected from a portion of samples. Simultaneous determination was achieved for the ten PIs. These results provide a reference to determine the PIs migrated from packing materials in beverage. This method is simple, high sensitive and non-polluting.

  1. Electrodeposition of self-assembled poly(3,4-ethylenedioxythiophene) @gold nanoparticles on stainless steel wires for the headspace solid-phase microextraction and gas chromatographic determination of several polycyclic aromatic hydrocarbons.

    PubMed

    Yang, Liu; Zhang, Jie; Zhao, Faqiong; Zeng, Baizhao

    2016-11-04

    In this work, a novel poly(3,4-ethylenedioxythiophene)@Au nanoparticles (PEDOT@AuNPs) hybrid coating was prepared and characterized. Firstly, the monomer 3,4-ethylenedioxythiophene was self-assembled on AuNPs, and then electropolymerization was performed on a stainless steel wire by cyclic voltammetry. The obtained PEDOT@AuNPs coating was rough and showed cauliflower-like micro-structure with thickness of ∼40μm. It displayed high thermal stability (up to 330°C) and mechanical stability and could be used for at least 160 times of solid phase microextraction (SPME) without decrease of extraction performance. The coating exhibited high extraction capacity for some environmental pollutants (e.g. naphthalene, 2-methylnaphthalene, acenaphthene, fluorene and phenathrene) due to the hydrophobic interaction between the analytes and PEDOT and the additional physicochemical affinity between polycyclic aromatic hydrocarbons and AuNPs. Through coupling with GC detection, good linearity (correlation coefficients higher than 0.9894), wide linear range (0.01-100μgL -1 ), low limits of detection (2.5-25ngL -1 ) were achieved for these analytes. The reproducibility (defined as RSD) was 1.1-4.0% and 5.8-9.9% for single fiber (n=5) and fiber-to-fiber (n=5), respectively. The SPME-GC method was successfully applied for the determination of three real samples, and the recoveries for standards added were 89.9-106% for lake water, 95.7-112% for rain water and 93.2-109% for soil saturated water, respectively. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Expanding the use of polymeric ionic liquids in headspace solid-phase microextraction: Determination of ultraviolet filters in water samples.

    PubMed

    Trujillo-Rodríguez, María J; Nan, He; Anderson, Jared L

    2018-03-09

    Three crosslinked polymeric ionic liquid (PIL) sorbent coatings were used in headspace solid-phase microextraction for the determination of a group of ultraviolet filters. The developed crosslinked PIL-based materials include two polycations and a double confined PIL. The method, in combination with gas chromatography-mass spectrometry, is simple, solvent free, and does not require of any derivatization step. After proper optimization of the methodologies with each developed fiber, the analytical performance was compared with a commercial polyacrylate fiber. A study of the normalized calibration slopes, obtained by dividing the calibration slope of each analyte by the coating volume, revealed that the crosslinked fibers can be used as alternatives to commercial fibers for the determination of the selected group of compounds. In particular, the coating nature of the PIL containing the 1-vinylbenzyl-3-hexadecylimidazolium bis[(trifluoromethyl)sulfonyl]imide IL as monomer and the 1,12-di(3-vinylbenzylimidazolium)dodecane bis[(trifluoromethyl)sulfonyl]imide IL as crosslinker is the most suitable for the extraction of the selected compounds despite their coating volume, being 3.6 times lower than the commercial polyacrylate fiber. For this fiber, wide linear ranges, correlation coefficients higher than 0.990, limits of detection ranging from 2.8 ng L -1 to 26 ng L -1 and relative standard deviations ranging from 2.5 to 15% were achieved. Finally, all proposed PIL-based fibers were applied towards the analysis of tap water, pool water and lake water, with the majority of the ultraviolet filters being detected and quantified in the last two types of samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Amine-functionalized MIL-53(Al)-coated stainless steel fiber for efficient solid-phase microextraction of synthetic musks and organochlorine pesticides in water samples.

    PubMed

    Xie, Lijun; Liu, Shuqin; Han, Zhubing; Jiang, Ruifen; Zhu, Fang; Xu, Weiqin; Su, Chengyong; Ouyang, Gangfeng

    2017-09-01

    The fiber coating is the key part of the solid-phase microextraction (SPME) technique, and it determines the sensitivity, selectivity, and repeatability of the analytical method. In this work, amine (NH 2 )-functionalized material of Institute Lavoisier (MIL)-53(Al) nanoparticles were successfully synthesized, characterized, and applied as the SPME fiber coating for efficient sample pretreatment owing to their unique structures and excellent adsorption properties. Under optimized conditions, the NH 2 -MIL-53(Al)-coated fiber showed good precision, low limits of detection (LODs) [0.025-0.83 ng L -1 for synthetic musks (SMs) and 0.051-0.97 ng L -1 for organochlorine pesticides (OCPs)], and good linearity. Experimental results showed that the NH 2 -MIL-53(Al) SPME coating was solvent resistant and thermostable. In addition, the extraction efficiencies of the NH 2 -MIL-53(Al) coating for SMs and OCPs were higher than those of commercially available SPME fiber coatings such as polydimethylsiloxane, polydimethylsiloxane-divinylbenzene, and polyacrylate. The reasons may be that the analytes are adsorbed on NH 2 -MIL-53(Al) primarily through π-π interactions, electron donor-electron acceptor interactions, and hydrogen bonds between the analytes and organic linkers of the material. Direct immersion (DI) SPME-gas chromatography-mass spectrometry methods based on NH 2 -MIL-53(Al) were successfully applied for the analysis of tap and river water samples. The recoveries were 80.3-115% for SMs and 77.4-117% for OCPs. These results indicate that the NH 2 -MIL-53(Al) coating may be a promising alternative to SPME coatings for the enrichment of SMs and OCPs.

  4. Electroplating of nanostructured polyaniline-polypyrrole composite coating in a stainless-steel tube for on-line in-tube solid phase microextraction.

    PubMed

    Asiabi, Hamid; Yamini, Yadollah; Seidi, Shahram; Esrafili, Ali; Rezaei, Fatemeh

    2015-06-05

    In this work, a novel and efficient on-line in-tube solid phase microextraction method followed by high performance liquid chromatography was developed for preconcentration and determination of trace amounts of parabens. A nanostructured polyaniline-polypyrrole composite was electrochemically deposited on the inner surface of a stainless steel tube and used as the extraction phase. Several important factors that influence the extraction efficiency, including type of solid-phase coating, extraction and desorption times, flow rates of the sample solution and eluent, pH, and ionic strength of the sample solution were investigated and optimized. Under the optimal conditions, the limits of detection were in the range of 0.02-0.04 μg L(-1). This method showed good linearity for parabens in the range of 0.07-50 μg L(-1), with coefficients of determination better than 0.998. The intra- and inter-assay precisions (RSD%, n=3) were in the range of 5.9-7.0% and 4.4-5.7% at three concentration levels of 2, 10, and 20 μg L(-1), respectively. The extraction recovery values for the spiked samples were in the acceptable range of 80.3-90.2%. The validated method was successfully applied for analysis of methyl-, ethyl-, and propyl parabens in some water, milk, and juice samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Abiotic Reductive Dechlorination of Tetrachloroethylene and Trichloroethylene in Anaerobic Environments

    DTIC Science & Technology

    2009-01-15

    Measurement of Henry’s Law Constant for methyl tert-butyl ether Using Solid-phase Microextraction. Environmental Toxicology and Chemistry 2001, 20, 1625...and Environmental Microbiology 2005, 71, 3413-3419. Nirmalakhandan, N. N., R. E. Speece. QSAR Model for Predicting Henry’s Constant. Environmental

  6. POLY(DIMETHYLSILOXANE) FILMS AS SORBENTS FOR SOLID PHASE MICROEXTRACTION COUPLED WITH INFRARED SPECTROSCOPY. (R825343)

    EPA Science Inventory

    The perspectives, information and conclusions conveyed in research project abstracts, progress reports, final reports, journal abstracts and journal publications convey the viewpoints of the principal investigator and may not represent the views and policies of ORD and EPA. Concl...

  7. Headspace Volatiles of Scutellaria Baicalensis Georgi Flowers

    USDA-ARS?s Scientific Manuscript database

    Volatile constituents of Baikal skullcap (Scutellaria baicalensis Georgi) flowers were isolated by solid-phase microextraction (SPME) and analyzed by GC and GC/MS. A total of 64 constituents was identified (constituting 57.1 – 89.9% of the total area), 13 of which were tentatively identified. beta...

  8. Characterization of volatile compounds of Mezcal, an ethnic alcoholic beverage obtained from Agave salmiana.

    PubMed

    De León-Rodríguez, Antonio; González-Hernández, Lidia; Barba de la Rosa, Ana P; Escalante-Minakata, Pilar; López, Mercedes G

    2006-02-22

    Commercial mezcals (white, white with worm, rested, rested with worm, and aged) produced from Agave salmiana were analyzed by solid-phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS). Thirty-seven compounds were identified, and nine of them were classified as major compounds of mezcal (MCM). Saturated alcohols, ethyl acetate, ethyl 2-hydroxypropanoate, and acetic acid form the MCM group. Minor compounds of mezcal group include other alcohols, aldehydes, ketones, large chain ethyl esters, organic acids, furans, terpenes, alkenes, and alkynes. Most of the compounds found in mezcals in this study are similar to those present in tequilas and other alcoholic beverages. However, mezcals contain unique compounds such as limonene and pentyl butanoate, which can be used as markers for the authenticity of mezcal produced from A. salmiana.

  9. Characterizing the Smell of Marijuana by Odor Impact of Volatile Compounds: An Application of Simultaneous Chemical and Sensory Analysis

    PubMed Central

    2015-01-01

    Recent US legislation permitting recreational use of marijuana in certain states brings the use of marijuana odor as probable cause for search and seizure to the forefront of forensic science, once again. This study showed the use of solid-phase microextraction with multidimensional gas chromatography—mass spectrometry and simultaneous human olfaction to characterize the total aroma of marijuana. The application of odor activity analysis offers an explanation as to why high volatile chemical concentration does not equate to most potent odor impact of a certain compound. This suggests that more attention should be focused on highly odorous compounds typically present in low concentrations, such as nonanal, decanol, o-cymene, benzaldehyde, which have more potent odor impact than previously reported marijuana headspace volatiles. PMID:26657499

  10. Identification of Campylobacter infection in chickens from volatile faecal emissions.

    PubMed

    Garner, Catherine E; Smith, Stephen; Elviss, Nicola C; Humphrey, Tom J; White, Paul; Ratcliffe, Norman M; Probert, Christopher S

    2008-06-01

    Volatile organic compounds from chicken faeces were investigated as biomarkers for Campylobacter infection. Campylobacter are major poultry-borne zoonotic pathogens, colonizing the avian intestinal tract. Chicken faeces are the principal source of contamination of carcasses. Fresh faeces were collected on farm sites, and Campylobacter status established microbiologically. Volatile organic compounds were pre-concentrated from the headspace above 71 separate faecal samples using solid-phase microextraction and separated and identified by gas chromatography/mass spectrometry. A Campylobacter-specific profile was identified using six of the extracted volatile organic compounds. The model developed reliably identified the presence or absence of Campylobacter in >95% of chickens. The volatile biomarker identification approach for assessing avian infection is a novel approach to enhancing biosecurity in the poultry industry and should reduce the risk of disease transmission to humans.

  11. Determination of Cinnamaldehyde in Cinnamon by SPME-GC-MS: An Instrumental Analysis Experiment

    ERIC Educational Resources Information Center

    Wang, Yimin; Ocariz, Jessica; Hammersand, Jennifer; MacDonald, Evan; Bartczak, Ashley; Kero, Frank; Young, Vaneica Y.; Williams, Kathryn R.

    2008-01-01

    Students analyze "trans"-cinnamaldehyde in commercial cinnamon using solid-phase microextraction and GC-MS with ethyl benzoate as the internal standard. Aside from the instrumentation, the experiment utilizes readily available low hazard materials and can be completed within one four-hour laboratory period. (Contains 2 figures.)

  12. APPLICATION OF SOLID PHASE MICROEXTRACTION GC/MS TO THE CHARACTERIZATION OF HYDROPHILIC DISINFECTION BY-PRODUCTS IN WATER

    EPA Science Inventory

    The U.S. Environmental Protection Agency has given high priority to research aimed at developing methods to extract hydrophilic disinfection by-products (DBPs) from drinking water. Public water supplies are treated with a variety of chemicals aimed at reducing or eliminating inf...

  13. Characterization of volatile and polar compounds of Jiaogulan Tea [Gynostemma pentaphyllum (Thunb.) Makino] by hyphenated analytical techniques

    USDA-ARS?s Scientific Manuscript database

    Jiaogulan [Gynostemma pentaphyllum (Thunb.) Makino] is a Chinese medical plant from southern Asia that has rapidly gained popularity and interest for its health-promotive and therapeutic properties. The volatile composition of jiaogulan tea was analyzed by using headspace-solid phase microextraction...

  14. SOLID-PHASE MICROEXTRACTION WITH PH ADJUSTMENT FOR THE DETERMINATION OF AROMATIC ACIDS AND BASES IN WATER. (R825368)

    EPA Science Inventory

    The perspectives, information and conclusions conveyed in research project abstracts, progress reports, final reports, journal abstracts and journal publications convey the viewpoints of the principal investigator and may not represent the views and policies of ORD and EPA. Concl...

  15. Solid-phase microextraction Ni-Ti fibers coated with functionalised silica particles immobilized in a sol-gel matrix.

    PubMed

    Azenha, Manuel; Ornelas, Mariana; Fernando Silva, A

    2009-03-20

    One of the possible approaches for the development of novel solid-phase microextraction (SPME) fibers is the physical deposition of porous materials onto a support using high-temperature epoxy glue. However, a major drawback arises from decomposition of epoxy glue at temperatures below 300 degrees C and instability in some organic solvents. This limitation motivated us to explore the possibility of replacing the epoxy glue with a sol-gel film, thermally more stable and resistant to organic solvents. We found that functionalised silica particles could be successfully attached to a robust Ni-Ti wire by using a UV-curable sol-gel film. The particles were found to be more important than the sol-gel layer during the microextraction process, as shown by competitive extraction trials and by the different extraction profiles observed with differently functionalised particles. If a quality control microscopic-check aiming at the rejection of fibers exhibiting unacceptably low particle load was conducted, acceptable (6-14%) reproducibility of preparation of C(18)-silica fibers was observed, and a strong indication of the durability of the fibers was also obtained. A cyclohexyldiol-silica fiber was used, as a simple example of applicability, for the successful determination of benzaldehyde, acetophenone and dimethylphenol at trace level in spiked tap water. Recoveries: 95-109%; limits of detection: 2-7 microg/L; no competition effects within the studied range (

  16. Method for sampling and analysis of volatile biomarkers in process gas from aerobic digestion of poultry carcasses using time-weighted average SPME and GC-MS.

    PubMed

    Koziel, Jacek A; Nguyen, Lam T; Glanville, Thomas D; Ahn, Heekwon; Frana, Timothy S; Hans van Leeuwen, J

    2017-10-01

    A passive sampling method, using retracted solid-phase microextraction (SPME) - gas chromatography-mass spectrometry and time-weighted averaging, was developed and validated for tracking marker volatile organic compounds (VOCs) emitted during aerobic digestion of biohazardous animal tissue. The retracted SPME configuration protects the fragile fiber from buffeting by the process gas stream, and it requires less equipment and is potentially more biosecure than conventional active sampling methods. VOC concentrations predicted via a model based on Fick's first law of diffusion were within 6.6-12.3% of experimentally controlled values after accounting for VOC adsorption to the SPME fiber housing. Method detection limits for five marker VOCs ranged from 0.70 to 8.44ppbv and were statistically equivalent (p>0.05) to those for active sorbent-tube-based sampling. The sampling time of 30min and fiber retraction of 5mm were found to be optimal for the tissue digestion process. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Method optimization for non-equilibrium solid phase microextraction sampling of HAPs for GC/MS analysis

    NASA Astrophysics Data System (ADS)

    Zawadowicz, M. A.; Del Negro, L. A.

    2010-12-01

    Hazardous air pollutants (HAPs) are usually present in the atmosphere at pptv-level, requiring measurements with high sensitivity and minimal contamination. Commonly used evacuated canister methods require an overhead in space, money and time that often is prohibitive to primarily-undergraduate institutions. This study optimized an analytical method based on solid-phase microextraction (SPME) of ambient gaseous matrix, which is a cost-effective technique of selective VOC extraction, accessible to an unskilled undergraduate. Several approaches to SPME extraction and sample analysis were characterized and several extraction parameters optimized. Extraction time, temperature and laminar air flow velocity around the fiber were optimized to give highest signal and efficiency. Direct, dynamic extraction of benzene from a moving air stream produced better precision (±10%) than sampling of stagnant air collected in a polymeric bag (±24%). Using a low-polarity chromatographic column in place of a standard (5%-Phenyl)-methylpolysiloxane phase decreased the benzene detection limit from 2 ppbv to 100 pptv. The developed method is simple and fast, requiring 15-20 minutes per extraction and analysis. It will be field-validated and used as a field laboratory component of various undergraduate Chemistry and Environmental Studies courses.

  18. Application of solid phase microextraction followed by liquid chromatography-mass spectrometry in the determination of antibiotic drugs and their metabolites in human whole blood and tissue samples.

    PubMed

    Szultka-Mlynska, Malgorzata; Pomastowski, Pawel; Buszewski, Boguslaw

    2018-06-01

    A sensitive, rapid and specific analytical method using high performance liquid chromatography coupled with mass spectrometry (HPLC-QqQ-MS) was developed to determine selected antibiotic drugs and their metabolites (amoxicillin, cefotaxime, ciprofloxacin, clindamycin and metronidazole; amoxycilloic acid, 4-hydroxyphenyl glycyl amoxicillin, desacetyl cefotaxime, 3-desacetyl cefotaxime lactone, ciprofloxacin N-oxide, N-demethylclindamycin, clindamycin sulfoxide, and hydroxy metronidazole) in human whole blood and vascularized tissue after single oral administration. The samples were prepared by solid phase microextraction with C18 fibers (SPME C18 ) and determined on a GRACE analytical C18 column, Vision HT (50 × 2 mm, 1.5 μm) at the flow rate of 0.4 mL min -1 using water and acetonitrile (containing 0.1% formic acid) as the mobile phase. The proposed method was successfully applied in a pharmacokinetic study of the selected antibiotic drugs and their metabolites in real human samples. Additionally, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI/TOF-MS) was used for identification and qualification analysis of the target compounds. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Chemical Analysis of the Chinese Liquor Luzhoulaojiao by Comprehensive Two-Dimensional Gas Chromatography/Time-of-Flight Mass Spectrometry

    PubMed Central

    Yao, Feng; Yi, Bin; Shen, Caihong; Tao, Fei; Liu, Yumin; Lin, Zhixin; Xu, Ping

    2015-01-01

    Luzhoulaojiao liquor is a type of Chinese liquor that dates back hundreds of years, but whose precise chemical composition remains unknown. This paper describes the screening of the liquor and the identification of its compounds using comprehensive two-dimensional gas chromatography/time-of-flight mass spectrometry (GC × GC/TOF-MS). Samples were prepared by both liquid-liquid extraction and solid-phase microextraction, which facilitated the detection of thousands of compounds in the liquor, thus demonstrating the superior performance of the proposed method over those reported in previous studies. A total of 320 compounds were common to all 18 types of Luzhoulaojiao liquor studied here, and 13 abundant and potentially bioactive compounds were further quantified. The results indicated that the high-performance method presented here is well suited for the detection and identification of compounds in liquors. This study also contributes to enriching our knowledge of the contents of Chinese liquors. PMID:25857434

  20. Monitoring the evolution of volatile compounds using gas chromatography during the stages of production of Moscatel sparkling wine.

    PubMed

    Soares, Rafael Dutra; Welke, Juliane Elisa; Nicolli, Karine Primieri; Zanus, Mauro; Caramão, Elina Bastos; Manfroi, Vitor; Zini, Cláudia Alcaraz

    2015-09-15

    This study reports, for the first time, the main changes that occur with some important aroma compounds of Moscatel sparkling wines during winemaking, measured using headspace solid-phase microextraction, one-dimensional and comprehensive two-dimensional gas chromatography (GC×GC) with mass spectrometry detection (MS). The best conditions of volatile extraction included the use of PDMS/DVB fibre, 2mL of wine, 30% of NaCl, 40°C for 30min. The chromatographic profile of sparkling wines showed decreasing amounts of monoterpenes (limonene, 4-terpineol, terpinolene, citronellol, α-terpineol, linalool, hotrienol, and nerol oxide), increasing amounts of esters (terpenyl esters, ethyl octanoate, ethyl decanoate and hexyl acetate) and alcohols (1-nonanol and 2-phenylethanol). Sixty-nine compounds co-eluted in the first dimension; only six co-eluted in the second dimension. GC×GC/TOFMS allows more detailed study of the volatile profile of sparkling wines. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Chemical Analysis of the Chinese Liquor Luzhoulaojiao by Comprehensive Two-Dimensional Gas Chromatography/Time-of-Flight Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Yao, Feng; Yi, Bin; Shen, Caihong; Tao, Fei; Liu, Yumin; Lin, Zhixin; Xu, Ping

    2015-04-01

    Luzhoulaojiao liquor is a type of Chinese liquor that dates back hundreds of years, but whose precise chemical composition remains unknown. This paper describes the screening of the liquor and the identification of its compounds using comprehensive two-dimensional gas chromatography/time-of-flight mass spectrometry (GC × GC/TOF-MS). Samples were prepared by both liquid-liquid extraction and solid-phase microextraction, which facilitated the detection of thousands of compounds in the liquor, thus demonstrating the superior performance of the proposed method over those reported in previous studies. A total of 320 compounds were common to all 18 types of Luzhoulaojiao liquor studied here, and 13 abundant and potentially bioactive compounds were further quantified. The results indicated that the high-performance method presented here is well suited for the detection and identification of compounds in liquors. This study also contributes to enriching our knowledge of the contents of Chinese liquors.

  2. Effects of milk fat, cocoa butter, or selected fat replacers on flavor volatiles of chocolate ice cream.

    PubMed

    Welty, W M; Marshall, R T; Grün, I U; Ellersieck, M R

    2001-01-01

    Selected volatile compounds of chocolate ice creams containing 0.6, 4.0, 6.0, or 9.0% milk fat or containing 2.5% milk fat, cocoa butter, or one of three fat replacers (Simplesse, Dairy Lo, or Oatrim) were analyzed by gas chromatography and gas chromatography-mass spectrometry using headspace solid-phase microextraction. The headspace concentration of most of the selected volatile compounds increased with decreasing milk fat concentration. Fat replacers generally increased the concentration of volatiles found in the headspace compared with milk fat or cocoa butter. Few differences in flavor volatiles were found between the ice cream containing milk fat and the ice cream containing cocoa butter. Among the selected volatiles, the concentration of 2,5-dimethyl-3(2-methyl propyl) pyrazine was the most highly correlated (negatively) with the concentration of milk fat, and it best discriminated among ice creams containing milk fat, cocoa butter, or one of the fat replacers.

  3. Fatty acid composition and its association with chemical and sensory analysis of boar taint.

    PubMed

    Liu, Xiaoye; Trautmann, Johanna; Wigger, Ruth; Zhou, Guanghong; Mörlein, Daniel

    2017-09-15

    A certain level of disagreement between the chemical analysis of androstenone and skatole and the human perception of boar taint has been found in many studies. Here we analyze whether the fatty acid composition can explain such inconsistency between sensory evaluation and chemical analysis of boar taint compounds. Therefore, back fat samples (n=143) were selected according to their sensory evaluation by a 10-person sensory panel, and the chemical analysis (stable isotope dilution analysis with headspace solid-phase microextraction and gas chromatography-mass spectrometry) of androstenone and skatole. Subsequently a quantification of fatty acids using gas chromatography-flame ionization detection was conducted. The correlation analyses revealed that several fatty acids are significantly correlated with androstenone, skatole, and the sensory rating. However, multivariate analyses (principal component analysis) revealed no explanation of the fatty acid composition with respect to the (dis-)agreement between sensory and chemical analysis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Ripening-dependent metabolic changes in the volatiles of pineapple (Ananas comosus (L.) Merr.) fruit: I. Characterization of pineapple aroma compounds by comprehensive two-dimensional gas chromatography-mass spectrometry.

    PubMed

    Steingass, Christof Björn; Carle, Reinhold; Schmarr, Hans-Georg

    2015-03-01

    Qualitative ripening-dependent changes of pineapple volatiles were studied via headspace solid-phase microextraction and analyzed by comprehensive two-dimensional gas chromatography quadrupole mass spectrometry (HS-SPME-GC×GC-qMS). Early green-ripe stage, post-harvest ripened, and green-ripe fruits at the end of their commercial shelf-life were compared to air-freighted pineapples harvested at full maturity. In total, more than 290 volatiles could be identified by mass spectrometry and their linear retention indices. The majority of compounds comprise esters (methyl and ethyl esters of saturated and unsaturated fatty acids, acetates), terpenes, alcohols, aldehydes, 2-ketones, free fatty acids, and miscellaneous γ- and δ-lactones. The structured separation space obtained by GC×GC allowed revealing various homologous series of compound classes as well as clustering of sesquiterpenes. Post-harvest ripening increased the diversity of the volatile profile compared to both early green-ripe maturity stages and on-plant ripened fruits.

  5. Saccharomyces cerevisiae oxidative response evaluation by cyclic voltammetry and gas chromatography-mass spectrometry.

    PubMed

    Castro, Cristiana C; Gunning, Caitriona; Oliveira, Carla M; Couto, José A; Teixeira, José A; Martins, Rui C; Ferreira, António C Silva

    2012-07-25

    This study is focused on the evaluation of the impact of Saccharomyces cerevisiae metabolism in the profile of compounds with antioxidant capacity in a synthetic wine during fermentation. A bioanalytical pipeline, which allows for biological systems fingerprinting and sample classification by combining electrochemical features with biochemical background, is proposed. To achieve this objective, alcoholic fermentations of a minimal medium supplemented with phenolic acids were evaluated daily during 11 days, for electrochemical profile, phenolic acids, and the volatile fermentation fraction, using cyclic voltametry, high-performance liquid chromatography-diode array detection, and headspace/solid-phase microextraction/gas chromatography-mass spectrometry (target and nontarget approaches), respectively. It was found that acetic acid, 2-phenylethanol, and isoamyl acetate are compounds with a significative contribution for samples metabolic variability, and the electrochemical features demonstrated redox-potential changes throughout the alcoholic fermentations, showing at the end a similar pattern to normal wines. Moreover, S. cerevisiae had the capacity of producing chlorogenic acid in the supplemented medium fermentation from simple precursors present in the minimal medium.

  6. Rapid determination of floral aroma compounds of lilac blossom by fast gas chromatography combined with surface acoustic wave sensor.

    PubMed

    Oh, Se Yeon; Shin, Hyun Du; Kim, Sung Jean; Hong, Jongki

    2008-03-07

    A novel analytical method using fast gas chromatography combined with surface acoustic wave sensor (GC/SAW) has been developed for the detection of volatile aroma compounds emanated from lilac blossom (Syringa species: Syringa vulgaris variginata and Syringa dilatata). GC/SAW could detect and quantify various fragrance emitted from lilac blossom, enabling to provide fragrance pattern analysis results. The fragrance pattern analysis could easily characterize the delicate differences in aromas caused by the substantial difference of chemical composition according to different color and shape of petals. Moreover, the method validation of GC/SAW was performed for the purpose of volatile floral actual aroma analysis, achieving a high reproducibility and excellent sensitivity. From the validation results, GC/SAW could serve as an alternative analytical technique for the analysis of volatile floral actual aroma of lilac. In addition, headspace solid-phase microextraction (HS-SPME) GC-MS was employed to further confirm the identification of fragrances emitted from lilac blossom and compared to GC/SAW.

  7. Development of a solid-phase microextraction gas chromatography with microelectron-capture detection method for a multiresidue analysis of pesticides in bovine milk.

    PubMed

    Fernandez-Alvarez, Maria; Llompart, Maria; Lamas, J Pablo; Lores, Marta; Garcia-Jares, Carmen; Cela, Rafael; Dagnac, Thierry

    2008-06-09

    A simple and rapid method based on solid-phase microextraction (SPME) technique followed by gas chromatography with microelectron-capture detection (GC-microECD) was developed for the simultaneous determination of more than 30 pesticides (pyrethroids and organochlorinated among others) in milk. To our knowledge, this is the first application of SPME for the determination of pyrethroid pesticides in milk. Negative matrix effects due to the complexity and lipophility of the studied matrix were reduced by diluting the sample with distilled water. A 2(5-1) fractional factorial design was performed to assess the influence of several factors (type of fiber coating, sampling mode, stirring, extraction temperature, and addition of sodium chloride) on the SPME procedure and to determine the optimal extraction conditions. After optimization of all the significant variables and interactions, the recommended procedure was established as follows: DSPME (using a polydimethylsiloxane (PDMS)/divinylbenzene (DVB) coating) of 1 mL of milk sample diluted with Milli-Q water (1:10 dilution ratio), at 100 degrees C, under stirring for 30 min. The proposed method showed good linearity and high sensitivity, with limits of detection (LOD) at the sub-ng mL(-1) level. Within a day and among days precisions were also evaluated (R.S.D.<15%). One of the most important attainments of this work was the use of external calibration with milk-matched standards to quantify the levels of the target analytes. The method was tested with liquid and powdered milk samples with different fat contents covering the whole commercial range. The efficiency of the extraction process was studied at several analyte concentration levels obtaining high recoveries (>80% in most cases) for different types of full-fat milks. The optimized procedure was validated with powdered milk certified reference material, which was quantified using external calibration and standard addition protocols. Finally, the DSPME-GC-microECD methodology was applied to the analysis of milk samples collected in farms of dairy cattle from NW Spain.

  8. Solid-phase microextraction/gas chromatography-mass spectrometry method optimization for characterization of surface adsorption forces of nanoparticles.

    PubMed

    Omanovic-Miklicanin, Enisa; Valzacchi, Sandro; Simoneau, Catherine; Gilliland, Douglas; Rossi, Francois

    2014-10-01

    A complete characterization of the different physico-chemical properties of nanoparticles (NPs) is necessary for the evaluation of their impact on health and environment. Among these properties, the surface characterization of the nanomaterial is the least developed and in many cases limited to the measurement of surface composition and zetapotential. The biological surface adsorption index approach (BSAI) for characterization of surface adsorption properties of NPs has recently been introduced (Xia et al. Nat Nanotechnol 5:671-675, 2010; Xia et al. ACS Nano 5(11):9074-9081, 2011). The BSAI approach offers in principle the possibility to characterize the different interaction forces exerted between a NP's surface and an organic--and by extension biological--entity. The present work further develops the BSAI approach and optimizes a solid-phase microextraction gas chromatography-mass spectrometry (SPME/GC-MS) method which, as an outcome, gives a better-defined quantification of the adsorption properties on NPs. We investigated the various aspects of the SPME/GC-MS method, including kinetics of adsorption of probe compounds on SPME fiber, kinetic of adsorption of probe compounds on NP's surface, and optimization of NP's concentration. The optimized conditions were then tested on 33 probe compounds and on Au NPs (15 nm) and SiO2 NPs (50 nm). The procedure allowed the identification of three compounds adsorbed by silica NPs and nine compounds by Au NPs, with equilibrium times which varied between 30 min and 12 h. Adsorption coefficients of 4.66 ± 0.23 and 4.44 ± 0.26 were calculated for 1-methylnaphtalene and biphenyl, compared to literature values of 4.89 and 5.18, respectively. The results demonstrated that the detailed optimization of the SPME/GC-MS method under various conditions is a critical factor and a prerequisite to the application of the BSAI approach as a tool to characterize surface adsorption properties of NPs and therefore to draw any further conclusions on their potential impact on health.

  9. Efficacy of head space solid-phase microextraction coupled to gas chromatography-mass spectrometry method for determination of the trace extracellular hydrocarbons of cyanobacteria.

    PubMed

    Guan, Wenna; Zhu, Tao; Wang, Yuejie; Zhang, Zhongyi; Jin, Zhao; Wang, Cong; Bai, Fali

    2016-09-01

    Hydrocarbons are widespread in cyanobacteria, and the biochemical synthetic pathways were recently identified. Intracellular fatty alka(e)nes of cyanobacteria have been detected by liquid-liquid extraction (LLE) coupled to gas chromatography-mass spectrometry (GC/MS). However, whether fatty alka(e)nes can be released to cyanobacterial culture media remains to be clarified. This work develops a sensitive method for analyzing the trace level of extracellular hydrocarbons in cyanobacterial culture media by head space solid-phase microextraction (HS-SPME) coupled to GC/MS. Headspace (HS) extraction mode using polydimethylsiloxane fiber to extract for 30min at 50°C was employed as the optimal extraction conditions. Five cyanobacterial fatty alka(e)nes analogs including pentadecene (C15:1), pentadecane (C15:0), heptadecene (C17:1), heptadecane (C17:0), nonadecane (C19:0) were analyzed, and the data obtained from HS-SPME-GC/MS method were quantified using internal standard peak area comparisons. Limits of detection (LOD), limits of quantitation (LOQ), linear dynamic range, precisions (RSD) and recovery for the analysis of extracellular fatty alka(e)nes of cyanobacteria by HS-SPME-GC/MS were evaluated. The LODs limits of detection (S/N = 3) varied from 10 to 21 ng L-1. The correlation coefficients (r) of the calibration curves ranged from 0.9873 to 0.9977 with a linearity from 0.1 to 50 μg L-1. The RSD values were ranging from 7.8 to 14.0% and from 4.0 to 8.8% at 1.0 μg L-1 and 10.0 μg L-1 standard solutions, respectively. Comparative analysis of extracellular fatty alka(e)nes in the culture media of model cyanobacteria Synechocystis sp. PCC 6803 demonstrated that sensitivity of HS-SPME-GC/MS method was significantly higher than LLE method. Finally, we found that heptadecane can be released into the culture media of Synechocystis sp. PCC 6803 at the later growth period. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Simultaneous determination of ochratoxin A and cyclopiazonic, mycophenolic, and tenuazonic acids in cornflakes by solid-phase microextraction coupled to high-performance liquid chromatography.

    PubMed

    Aresta, Antonella; Cioffi, Nicola; Palmisano, Francesco; Zambonin, Carlo G

    2003-08-27

    A solid-phase microextraction (SPME) method, coupled to liquid chromatography with diode array UV detection (LC-UV/DAD), for the simultaneous determination of cyclopiazonic acid, mycophenolic acid, tenuazonic acid, and ochratoxin A is described. Chromatographic separation was achieved on a propylamino-bonded silica gel stationary phase using acetonitrile/methanol/ammonium acetate buffer mixture (78:2:20, v/v/v) as mobile phase. SPME adsorption and desorption conditions were optimized using a silica fiber coated with a 60 microm thick polydimethylsiloxane/divinylbenzene film. Estimated limits of detection and limits of quantitation ranged from 3 to 12 ng/mL and from 7 to 29 ng/mL, respectively. The method has been applied to cornflake samples. Samples were subjected to a preliminary short sonication in MeOH/2% KHCO(3) (70:30, v/v); the mixture was evaporated to near dryness and reconstituted in 1.5 mL of 5 mM phosphate buffer (pH 3) for SPME followed by LC-UV/DAD. The overall procedure had recoveries (evaluated on samples spiked at 200 ng/g level) ranging from 74 +/- 4 to 103 +/- 9%. Samples naturally contaminated with cyclopiazonic and tenuazonic acids were found; estimated concentrations were 72 +/- 9 and 25 +/- 6 ng/g, respectively.

  11. Analysis of tricyclic antidepressant drugs in plasma by means of solid-phase microextraction-liquid chromatography-mass spectrometry.

    PubMed

    Alves, Claudete; Santos-Neto, Alvaro J; Fernandes, Christian; Rodrigues, José C; Lanças, Fernando M

    2007-10-01

    Solid-phase microextraction coupled to liquid chromatography and mass spectrometry (SPME-LC-MS) was used to analyze tricyclic antidepressant drugs desipramine, imipramine, nortriptyline, amitriptyline, and clomipramine (internal standard) in plasma samples. SPME was performed by direct extraction on a PDMS/DVB (60 microm) coated fiber, employing a stirring rate of 1200 rpm for 30 min, pH 11.0, and temperature of 30 degrees C. Drug desorption was carried out by exposing the fiber to the liquid chromatography mobile phase for 20 min, using a labmade SPME-LC interface at 50 degrees C. The main variables experimentally influencing LC-MS response were evaluated and mathematically modeled. A rational optimization with fewer experiments was achieved using a factorial design approach. The constructed empirical models were adjusted with 96-98% of explained deviation allowing an adequate data set comprehension. The chromatographic separation was realized using an RP-18 column (150 mm x 2.1 mm, 5 microm particles) and ammonium acetate buffer (0.01 mol/l, pH 5.50) : acetonitrile (50 : 50 v/v) as mobile phase. Low detection levels were achieved with electrospray interface (0.1 ng/ml). The developed method showed specificity, linearity, precision, and limit of quantification adequate to assay tricyclic antidepressant drugs in plasma.

  12. Headspace sorptive solid phase microextraction (HS-SPME) combined with a spectrophotometry system: A simple glass devise for extraction and simultaneous determination of cyanide and thiocyanate in environmental and biological samples.

    PubMed

    Al-Saidi, H M; Al-Harbi, Sami A; Aljuhani, E H; El-Shahawi, M S

    2016-10-01

    A simple, low cost and efficient headspace sorptive solid phase microextraction (HS-SPME) method for determination of cyanide has been developed. The system comprises of a glass tube with two valves and a moveable glass slide fixed at its centre. It includes an acceptor phase polyurethane foam treated mercury (II) dithizonate [Hg(HDz)2-PUF] complex fixed inside by a septum cap in a cylindrical configuration (5.0cm length and 1.0cm diameter). The extraction is based upon the contact of the acceptor phase to the headspace and subsequently measuring the absorbance of the recovered mercury (II) dithizonate from PUFs sorbent. Unlike other HSSE, extraction and back - extractions was carried out in a closed system, thereby improving the analytical performance by preventing the analyte loss. Under the optimized conditions, a linear calibration plot in the range of 1.0-50.0µmolL(-1) was achieved with limits of detection (LOD) and quantification (LOQ) of 0.34, 1.2µmolL(-1) CN(-), respectively. Simultaneous analysis of cyanide and thiocyanate in saliva was also performed with satisfactory recoveries. Copyright © 2016. Published by Elsevier B.V.

  13. An Approach Using Gas Monitoring to Find the Residual TCE Location in the Unsaturated Zone of Woosan Industrial Complex (WIC), Korea

    NASA Astrophysics Data System (ADS)

    Koh, Y.; Lee, S.; Yang, J.; Lee, K.

    2012-12-01

    An area accommodating various industrial facilities has fairly high probability of groundwater contamination with multiple chlorinated solvents such as trichloroethene (TCE), carbon tetrachloride (CT), and chloroform (CF). Source tracing of chlorinated solvents in the unsaturated zone is an essential procedure for the management and remediation of contaminated area. From the previous study on seasonal variations in hydrological stresses and spatial variations in geologic conditions on a TCE plume, the existence of residual DNAPLs at or above the water table has proved. Since TCE is one of the frequently detected VOCs (Volatile Organic Compounds) in groundwater, residual TCE can be detected by gas monitoring. Therefore, monitoring of temporal and spatial variations in the gas phase TCE contaminant at an industrial complex in Wonju, Korea, were used to find the residual TCE locations. As pilot tests, TCE gas samples collected in the unsaturated zone at 4 different wells were analyzed using SPME (Solid Phase MicroExtraction) fiber and Gas Chromatography (GC). The results indicated that detecting TCE in gas phase was successful from these wells and TCE analysis on gas samples, collected from the unsaturated zone, will be useful for source area characterization. However, some values were too high to doubt the accuracy of the current method, which needs a preliminary lab test with known concentrations. The modified experiment setups using packer at different depths are in process to find residual TCE locations in the unsaturated zone. Meanwhile, several PVD (polyethylene-membrane Passive Vapor Diffusion) samplers were placed under water table to detect VOCs by equilibrium between air in the vial and VOCs in pore water.

  14. A liquid-phase microextraction method, combining a dual gauge microsyringe with a hollow fiber membrane, for the determination of organochlorine pesticides in aqueous solution by gas chromatography/ion trap mass spectrometry.

    PubMed

    Yan, Chih-Hao; Wu, Hui-Fen

    2004-01-01

    A liquid-phase microextraction (LPME) method has been demonstrated for the extraction and determination of organochlorine pesticides (OCPs) in aqueous solution. The method combines a dual gauge microsyringe with a hollow fiber membrane (LPME/DGM-HF) followed by detection by gas chromatography/ion trap mass spectrometry (GC/ITMS). The advantages include speed, low solvent and sample consumption, simplicity and ease of use. The extraction time, solvent selection, salt concentration and sample stirring rate have been investigated in order to optimize extraction efficiency. The viability is evaluated by measuring the linearity and detection limit of the five OCPs in aqueous solution. Detection linearity for the OCPs has been achieved over a range of concentrations between 1 and 500 microg/L (r2 > 0.930), with a detection limit of 0.1 microg/L for each OCP. Copyright 2004 John Wiley & Sons, Ltd.

  15. Effectiveness of high-throughput miniaturized sorbent- and solid phase microextraction techniques combined with gas chromatography-mass spectrometry analysis for a rapid screening of volatile and semi-volatile composition of wines--a comparative study.

    PubMed

    Mendes, Berta; Gonçalves, João; Câmara, José S

    2012-01-15

    In this study the feasibility of different extraction procedures was evaluated in order to test their potential for the extraction of the volatile (VOCs) and semi-volatile constituents (SVOCs) from wines. In this sense, and before they could be analysed by gas chromatography-quadrupole first stage masss spectrometry (GC-qMS), three different high-throughput miniaturized (ad)sorptive extraction techniques, based on solid phase extraction (SPE), microextraction by packed sorbents (MEPS) and solid phase microextraction (SPME), were studied for the first time together, for the extraction step. To achieve the most complete volatile and semi-volatile signature, distinct SPE (LiChrolut EN, Poropak Q, Styrene-Divinylbenzene and Amberlite XAD-2) and MEPS (C(2), C(8), C(18), Silica and M1 (mixed C(8)-SCX)) sorbent materials, and different SPME fibre coatings (PA, PDMS, PEG, DVB/CAR/PDMS, PDMS/DVB, and CAR/PDMS), were tested and compared. All the extraction techniques were followed by GC-qMS analysis, which allowed the identification of up to 103 VOCs and SVOCs, distributed by distinct chemical families: higher alcohols, esters, fatty acids, carbonyl compounds and furan compounds. Mass spectra, standard compounds and retention index were used for identification purposes. SPE technique, using LiChrolut EN as sorbent (SPE(LiChrolut EN)), was the most efficient method allowing for the identification of 78 VOCs and SVOCs, 63 and 19 more than MEPS and SPME techniques, respectively. In MEPS technique the best results in terms of number of extractable/identified compounds and total peak areas of volatile and semi-volatile fraction, were obtained by using C(8) resin whereas DVB/CAR/PDMS was revealed the most efficient SPME coating to extract VOCs and SVOCs from Bual wine. Diethyl malate (18.8±3.2%) was the main component found in wine SPE(LiChrolut EN) extracts followed by ethyl succinate (13.5±5.3%), 3-methyl-1-butanol (13.2±1.7%), and 2-phenylethanol (11.2±9.9%), while in SPME(DVB/CAR/PDMS) technique 3-methyl-1-butanol (43.3±0.6%) followed by diethyl succinate (18.9±1.6%), and 2-furfural (10.4±0.4%), are the major compounds. The major VOCs and SVOCs isolated by MEPS(C8) were 3-methyl-1-butanol (26.8±0.6%, from wine total volatile fraction), diethyl succinate (24.9±0.8%), and diethyl malate (16.3±0.9%). Regardless of the extraction technique, the highest extraction efficiency corresponds to esters and higher alcohols and the lowest to fatty acids. Despite some drawbacks associated with the SPE procedure such as the use of organic solvents, the time-consuming and tedious sampling procedure, it was observed that SPE(LiChrolut EN), revealed to be the most effective technique allowing the extraction of a higher number of compounds (78) rather than the other extraction techniques studied. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. Deep eutectic solvent based gas-assisted dispersive liquid-phase microextraction combined with gas chromatography and flame ionization detection for the determination of some pesticide residues in fruit and vegetable samples.

    PubMed

    Farajzadeh, Mir Ali; Sattari Dabbagh, Masoumeh; Yadeghari, Adeleh

    2017-05-01

    In this study, a gas-assisted dispersive liquid-phase microextraction method using a deep eutectic solvent as the extraction solvent combined with gas chromatography and flame ionization detection was developed for the extraction and determination of some pesticide residues in vegetable and fruit juice samples. In this method, choline chloride and 4-chlorophenol at a molar ratio of 1:2 were mixed. By heating and vortexing, a clear, water-immiscible, and homogeneous liquid was formed. The obtained deep eutectic solvent was added to an aqueous solution of the analytes in a conical test tube. Air was bubbled into the aqueous solution and a cloudy solution was obtained. During this step, the analytes were extracted into the fine droplets of the extraction solvent. After centrifugation, an aliquot of the settled phase was injected into the separation system. Under the optimum extraction conditions, enrichment factors, and extraction recoveries were obtained in the ranges of 247-355 and 49-71%, respectively. The obtained values for the limits of detection and quantification were in the ranges of 0.24-1.4 and 0.71-4.2 μg/L, respectively. The proposed method is simple, fast, efficient, and inexpensive. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Gas-assisted dispersive liquid-phase microextraction using ionic liquid as extracting solvent for spectrophotometric speciation of copper.

    PubMed

    Akhond, Morteza; Absalan, Ghodratollah; Pourshamsi, Tayebe; Ramezani, Amir M

    2016-07-01

    Gas-assisted dispersive liquid-phase microextraction (GA-DLPME) has been developed for preconcentration and spectrophotometric determination of copper ion in different water samples. The ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate and argon gas, respectively, were used as the extracting solvent and disperser. The procedure was based on direct reduction of Cu(II) to Cu(I) by hydroxylamine hydrochloride, followed by extracting Cu(I) into ionic liquid phase by using neocuproine as the chelating agent. Several experimental variables that affected the GA-DLPME efficiency were investigated and optimized. Under the optimum experimental conditions (IL volume, 50µL; pH, 6.0; acetate buffer, 1.5molL(-1); reducing agent concentration, 0.2molL(-1); NC concentration, 120µgmL(-1); Ar gas bubbling time, 6min; argon flow rate, 1Lmin(-1); NaCl concentration, 6% w/w; and centrifugation time, 3min), the calibration graph was linear over the concentration range of 0.30-2.00µgmL(-1) copper ion with a limit of detection of 0.07µgmL(-1). Relative standard deviation for five replicate determinations of 1.0µgmL(-1) copper ion was found to be 3.9%. The developed method was successfully applied to determination of both Cu(I) and Cu(II) species in water samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Identification of Chemicals Emitted by Calling Males of the Sapote Fruit Fly, Anastrepha serpentina (Diptera: Tephritidae)

    USDA-ARS?s Scientific Manuscript database

    Emissions from sexually active Anastrepha serpentine males were collected by solid-phase microextraction. Calling behavior of wild-type males showed no clear peak during the day, except that it was evident less frequently immediately after daybreak and just before dark. Calling by laboratory males...

  19. Identification of chemicals emitted by calling males of the Sapote fruit fly, Anastrepha serpentina (Diptera: Tephritidae)

    USDA-ARS?s Scientific Manuscript database

    Emissions from sexually active Anastrepha serpentine males were collected by solid-phase microextraction. Calling behavior of wild-type males showed no clear peak during the day except that calling was less frequent immediately after daybreak and just before dark. Calling by laboratory males was h...

  20. HETEROGENIC CATALYTIC HYDROLYSIS AND ANALYSIS OF NATURAL PYRETHRINS IN SUBCRITICAL WATER COUPLED WITH SOLID-PHASE MICROEXTRACTION (SPME) AND GC/MS. (R825368)

    EPA Science Inventory

    The perspectives, information and conclusions conveyed in research project abstracts, progress reports, final reports, journal abstracts and journal publications convey the viewpoints of the principal investigator and may not represent the views and policies of ORD and EPA. Concl...

Top