DOE Office of Scientific and Technical Information (OSTI.GOV)
Malcolm Pitts; Jie Qi; Dan Wilson
2005-04-01
Gelation technologies have been developed to provide more efficient vertical sweep efficiencies for flooding naturally fractured oil reservoirs or more efficient areal sweep efficiency for those with high permeability contrast ''thief zones''. The field proven alkaline-surfactant-polymer technology economically recovers 15% to 25% OOIP more oil than waterflooding from swept pore space of an oil reservoir. However, alkaline-surfactant-polymer technology is not amenable to naturally fractured reservoirs or those with thief zones because much of injected solution bypasses target pore space containing oil. This work investigates whether combining these two technologies could broaden applicability of alkaline-surfactant-polymer flooding into these reservoirs. A priormore » fluid-fluid report discussed interaction of different gel chemical compositions and alkaline-surfactant-polymer solutions. Gel solutions under dynamic conditions of linear corefloods showed similar stability to alkaline-surfactant-polymer solutions as in the fluid-fluid analyses. Aluminum-polyacrylamide, flowing gels are not stable to alkaline-surfactant-polymer solutions of either pH 10.5 or 12.9. Chromium acetate-polyacrylamide flowing and rigid flowing gels are stable to subsequent alkaline-surfactant-polymer solution injection. Rigid flowing chromium acetate-polyacrylamide gels maintained permeability reduction better than flowing chromium acetate-polyacrylamide gels. Silicate-polyacrylamide gels are not stable with subsequent injection of either a pH 10.5 or a 12.9 alkaline-surfactant-polymer solution. Chromium acetate-xanthan gum rigid gels are not stable to subsequent alkaline-surfactant-polymer solution injection. Resorcinol-formaldehyde gels were stable to subsequent alkaline-surfactant-polymer solution injection. When evaluated in a dual core configuration, injected fluid flows into the core with the greatest effective permeability to the injected fluid. The same gel stability trends to subsequent alkaline-surfactant-polymer injected solution were observed. Aluminum citrate-polyacrylamide, resorcinol-formaldehyde, and the silicate-polyacrylamide gel systems did not produce significant incremental oil in linear corefloods. Both flowing and rigid flowing chromium acetate-polyacrylamide gels and the xanthan gum-chromium acetate gel system produced incremental oil with the rigid flowing gel producing the greatest amount. Higher oil recovery could have been due to higher differential pressures across cores. None of the gels tested appeared to alter alkaline-surfactant-polymer solution oil recovery. Total waterflood plus chemical flood oil recovery sequence recoveries were all similar.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Malcolm Pitts; Jie Qi; Dan Wilson
2005-10-01
Gelation technologies have been developed to provide more efficient vertical sweep efficiencies for flooding naturally fractured oil reservoirs or more efficient areal sweep efficiency for those with high permeability contrast ''thief zones''. The field proven alkaline-surfactant-polymer technology economically recovers 15% to 25% OOIP more oil than waterflooding from swept pore space of an oil reservoir. However, alkaline-surfactant-polymer technology is not amenable to naturally fractured reservoirs or those with thief zones because much of injected solution bypasses target pore space containing oil. This work investigates whether combining these two technologies could broaden applicability of alkaline-surfactant-polymer flooding into these reservoirs. A priormore » fluid-fluid report discussed interaction of different gel chemical compositions and alkaline-surfactant-polymer solutions. Gel solutions under dynamic conditions of linear corefloods showed similar stability to alkaline-surfactant-polymer solutions as in the fluid-fluid analyses. Aluminum-polyacrylamide, flowing gels are not stable to alkaline-surfactant-polymer solutions of either pH 10.5 or 12.9. Chromium acetate-polyacrylamide flowing and rigid flowing gels are stable to subsequent alkaline-surfactant-polymer solution injection. Rigid flowing chromium acetate-polyacrylamide gels maintained permeability reduction better than flowing chromium acetate-polyacrylamide gels. Silicate-polyacrylamide gels are not stable with subsequent injection of either a pH 10.5 or a 12.9 alkaline-surfactant-polymer solution. Chromium acetate-xanthan gum rigid gels are not stable to subsequent alkaline-surfactant-polymer solution injection. Resorcinol-formaldehyde gels were stable to subsequent alkaline-surfactant-polymer solution injection. When evaluated in a dual core configuration, injected fluid flows into the core with the greatest effective permeability to the injected fluid. The same gel stability trends to subsequent alkaline-surfactant-polymer injected solution were observed. Aluminum citrate-polyacrylamide, resorcinol-formaldehyde, and the silicate-polyacrylamide gel systems did not produce significant incremental oil in linear corefloods. Both flowing and rigid flowing chromium acetate-polyacrylamide gels and the xanthan gum-chromium acetate gel system produced incremental oil with the rigid flowing gel producing the greatest amount. Higher oil recovery could have been due to higher differential pressures across cores. None of the gels tested appeared to alter alkaline-surfactant-polymer solution oil recovery. Total waterflood plus chemical flood oil recovery sequence recoveries were all similar. Chromium acetate-polyacrylamide gel used to seal fractured core maintain fracture closure if followed by an alkaline-surfactant-polymer solution. Chromium acetate gels that were stable to injection of alkaline-surfactant-polymer solutions at 72 F were stable to injection of alkaline-surfactant-polymer solutions at 125 F and 175 F in linear corefloods. Chromium acetate-polyacrylamide gels maintained diversion capability after injection of an alkaline-surfactant-polymer solution in stacked; radial coreflood with a common well bore. Xanthan gum-chromium acetate gels maintained gel integrity in linear corefloods after injection of an alkaline-surfactant-polymer solution at 125 F. At 175 F, Xanthan gum-chromium acetate gels were not stable either with or without subsequent alkaline-surfactant-polymer solution injection. Numerical simulation demonstrated that reducing the permeability of a high permeability zone of a reservoir with gel improved both waterflood and alkaline-surfactant-polymer flood oil recovery. A Minnelusa reservoir with both A and B sand production was simulated. A and B sands are separated by a shale layer. A sand and B sand waterflood oil recovery was improved by 196,000 bbls when a gel was placed in the B sand. A sand and B sand alkaline-surfactant-polymer flood oil recovery was improved by 596,000 bbls when a gel was placed in the B sand. Alkaline-surfactant-polymer flood oil recovery improvement over a waterflood was 392,000 bbls. Placing a gel into the B sand prior to an alkaline-surfactant-polymer flood resulted in 989,000 bbl more oil than only water injection.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Malcolm Pitts; Jie Qi; Dan Wilson
2005-12-01
Gelation technologies have been developed to provide more efficient vertical sweep efficiencies for flooding naturally fractured oil reservoirs or reservoirs with different sand lenses with high permeability contrast. The field proven alkaline-surfactant-polymer technology economically recovers 15% to 25% OOIP more crude oil than waterflooding froin swept pore space of an oil reservoir. However, alkaline-surfactant-polymer technology is not amenable to naturally fractured reservoirs or reservoirs with high permeability contrast zones because much of injected solution bypasses target pore space containing oil. This work investigates whether combining these two technologies could broaden applicability of alkaline-surfactant-polymer flooding into these reservoirs. Fluid-fluid interaction withmore » different gel chemical compositions and alkaline-surfactant-polymer solution with pH values ranging from 9.2 to 12.9 have been tested. Aluminum-polyacrylamide gels are not stable to alkaline-surfactant-polymer solutions at any pH. Chromium-polyacrylamide gels with polymer to chromium ion ratios of 25 or greater were stable to alkaline-surfactant-polymer solutions if solution pH was 10.6 or less. When the polymer to chromium ion was 15 or less, chromium-polyacrylamide gels were stable to alkaline-surfactant-polymer solutions with pH values up to 12.9. Chromium-xanthan gum gels were stable to alkaline-surfactant-polymer solutions with pH values of 12.9 at the polymer to chromium ion ratios tested. Silicate-polyacrylamide, resorcinol-formaldehyde, and sulfomethylated resorcinol-formaldehyde gels were also stable to alkaline-surfactant-polymer solutions with pH values ranging from 9.2 to 12.9. Iron-polyacrylamide gels were immediately destroyed when contacted with any of the alkaline-surfactant-polymer solutions with pH values ranging from 9.2 to 12.9. Gel solutions under dynamic conditions of linear corefloods showed similar stability to alkaline-surfactant-polymer solutions as in the fluid-fluid analyses with the exception of the xanthan gum-chromium acetate gels. Aluminum-polyacrylamide flowing gels are not stable to alkaline-surfactant-polymer solutions of either pH 10.5 or 12.9, either in linear corefloods or in dual separate radial core, common manifold corefloods. Chromium acetate-polyacrylamide flowing and rigid tonguing gels are stable to subsequent alkaline-surfactant-polymer solution injection. Rigid tonguing chromium acetate-polyacrylamide gels maintained permeability reduction better than flowing chromium acetate-polyacrylamide gels. Chromium acetate gels were stable to injection of alkaline-surfactant-polymer solutions at 72 F, 125 F and 175 F in linear corefloods. Chromium acetate-polyacrylamide gels maintained diversion capability after injection of an alkaline-surfactant-polymer solution in stacked; radial coreflood with a common well bore. Chromium acetate-polyacrylamide gel used to seal fractured core maintain fracture closure if followed by an alkaline-surfactant-polymer solution. Chromium acetate-xanthan gum rigid gels are not stable to subsequent alkaline-surfactant-polymer solution injection at 72, 125, and 175 F. Silicate-polyacrylamide gels are not stable with subsequent injection of either a pH 10.5 or a 12.9 alkaline-surfactant-polymer solution. Resorcinol-formaldehyde gels were stable to subsequent alkaline-surfactant-polymer solution injection. When evaluated in a dual core configuration, injected fluid flows into the core with the greatest effective permeability to the injected fluid. The same gel stability trends to subsequent alkaline-surfactant-polymer injected solution were observed. Aluminum citrate-polyacrylamide, resorcinol-formaldehyde, and the silicate-polyacrylamide gel systems did not produce significant incremental oil in linear corefloods. Both flowing and rigid tonguing chromium acetate-polyacrylamide gels and the xanthan gum-chromium acetate gel system produced incremental oil with the rigid tonguing gel producing the greatest amount. Higher oil recovery could have been due to higher differential pressures across cores. Aluminum citrate-polyacrylamide gels, chromium acetate-polyacrylamide gels, silicate-polymer, and chromium-xanthan guin gels did not alter an alkaline-surfactant-polymer solution's ability to produce incremental oil. Incremental oil was reduced with the resorcinol-formaldehyde gel system. Total waterflood plus chemical flood oil recovery sequence recoveries were generally similar.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Malcolm Pitts; Jie Qi; Dan Wilson
2005-12-01
Gelation technologies have been developed to provide more efficient vertical sweep efficiencies for flooding naturally fractured oil reservoirs or reservoirs with different sand lenses with high permeability contrast. The field proven alkaline-surfactant-polymer technology economically recovers 15% to 25% OOIP more crude oil than waterflooding from swept pore space of an oil reservoir. However, alkaline-surfactant-polymer technology is not amenable to naturally fractured reservoirs or reservoirs with high permeability contrast zones because much of injected solution bypasses target pore space containing oil. This work investigates whether combining these two technologies could broaden applicability of alkaline-surfactant-polymer flooding into these reservoirs. Fluid-fluid interaction withmore » different gel chemical compositions and alkaline-surfactant-polymer solution with pH values ranging from 9.2 to 12.9 have been tested. Aluminum-polyacrylamide gels are not stable to alkaline-surfactant-polymer solutions at any pH. Chromium-polyacrylamide gels with polymer to chromium ion ratios of 25 or greater were stable to alkaline-surfactant-polymer solutions if solution pH was 10.6 or less. When the polymer to chromium ion was 15 or less, chromium-polyacrylamide gels were stable to alkaline-surfactant-polymer solutions with pH values up to 12.9. Chromium-xanthan gum gels were stable to alkaline-surfactant-polymer solutions with pH values of 12.9 at the polymer to chromium ion ratios tested. Silicate-polyacrylamide, resorcinol-formaldehyde, and sulfomethylated resorcinol-formaldehyde gels were also stable to alkaline-surfactant-polymer solutions with pH values ranging from 9.2 to 12.9. Iron-polyacrylamide gels were immediately destroyed when contacted with any of the alkaline-surfactant-polymer solutions with pH values ranging from 9.2 to 12.9. Gel solutions under dynamic conditions of linear corefloods showed similar stability to alkaline-surfactant-polymer solutions as in the fluid-fluid analyses with the exception of the xanthan gum-chromium acetate gels. Aluminum-polyacrylamide flowing gels are not stable to alkaline-surfactant-polymer solutions of either pH 10.5 or 12.9, either in linear corefloods or in dual separate radial core, common manifold corefloods. Chromium acetate-polyacrylamide flowing and rigid tonguing gels are stable to subsequent alkaline-surfactant-polymer solution injection. Rigid tonguing chromium acetate-polyacrylamide gels maintained permeability reduction better than flowing chromium acetate-polyacrylamide gels. Chromium acetate gels were stable to injection of alkaline-surfactant-polymer solutions at 72 F, 125 F and 175 F in linear corefloods. Chromium acetate-polyacrylamide gels maintained diversion capability after injection of an alkaline-surfactant-polymer solution in stacked; radial coreflood with a common well bore. Chromium acetate-polyacrylamide gel used to seal fractured core maintain fracture closure if followed by an alkaline-surfactant-polymer solution. Chromium acetatexanthan gum rigid gels are not stable to subsequent alkaline-surfactant-polymer solution injection at 72, 125, and 175 F. Silicate-polyacrylamide gels are not stable with subsequent injection of either a pH 10.5 or a 12.9 alkaline-surfactant-polymer solution. Resorcinol-formaldehyde gels were stable to subsequent alkaline-surfactant-polymer solution injection. When evaluated in a dual core configuration, injected fluid flows into the core with the greatest effective permeability to the injected fluid. The same gel stability trends to subsequent alkaline-surfactant-polymer injected solution were observed. Aluminum citrate-polyacrylamide, resorcinol-formaldehyde, and the silicate-polyacrylamide gel systems did not produce significant incremental oil in linear corefloods. Both flowing and rigid tonguing chromium acetate-polyacrylamide gels and the xanthan gum-chromium acetate gel system produced incremental oil with the rigid tonguing gel producing the greatest amount. Higher oil recovery could have been due to higher differential pressures across cores. Aluminum citrate-polyacrylamide gels, chromium acetate-polyacrylamide gels, silicate-polymer, and chromium-xanthan gum gels did not alter an alkaline-surfactant-polymer solution's ability to produce incremental oil. Incremental oil was reduced with the resorcinol-formaldehyde gel system. Total waterflood plus chemical flood oil recovery sequence recoveries were generally similar. Performance and produced polymer evaluation of four alkaline-surfactant-polymer projects concluded that only one of the projects could have benefited from combining the alkaline-surfactant-polymer and gelation technologies. Cambridge, the 1993 Daqing, Mellott Ranch, and the Wardlaw alkaline-surfacant-polymer floods were studied. An initial gel treatment followed by an alkaline-surfactant-polymer flood in the Wardlaw field would have been a benefit due to reduction of fracture flow.« less
Sorption of amiodarone to polyvinyl chloride infusion bags and administration sets.
Weir, S J; Myers, V A; Bengtson, K D; Ueda, C T
1985-12-01
The loss of amiodarone from i.v. admixtures to flexible polyvinyl chloride (PVC) infusion bags and i.v. administration sets was studied. Admixtures containing amiodarone hydrochloride 600 micrograms/mL and either 5% dextrose injection or 0.9% sodium chloride injection were stored at room temperature in glass bottles (both with and without contact of the drug solution with the rubber bottle closure), in flexible PVC bags, or in rigid PVC bottles. After 120 hours, the contents of each flexible PVC bag were emptied and replaced by methanol, which was allowed to remain in the bag for an additional 120 hours and was then analyzed for amiodarone content. To determine availability of amiodarone after infusion through a 1.8-m PVC i.v. administration set, solutions stored in glass containers were run through the set at 0.5 mL/min for 90 minutes. Samples of drug solutions were collected at appropriate intervals and analyzed by a stability-indicating high-performance liquid chromatography (HPLC) assay. Admixtures containing 0.9% sodium chloride injection were not stable; visual incompatibility was evident after 24 hours of storage in glass bottles, and no further testing was performed. In admixtures containing 5% dextrose injection that were stored in 50-mL flexible PVC bags, 60% of the initial amiodarone concentration remained after 120 hours; approximately half of the lost drug was recovered with the methanol. In effluent collected from the PVC administration set, 82% of the initial amiodarone concentration remained. Amiodarone concentrations did not decrease appreciably, after storage in glass or rigid PVC bottles, indicating that drug loss was probably affected by the plasticizer, di-2-ethylhexyl phthalate.(ABSTRACT TRUNCATED AT 250 WORDS)
Nonlinear core deflection in injection molding
NASA Astrophysics Data System (ADS)
Poungthong, P.; Giacomin, A. J.; Saengow, C.; Kolitawong, C.; Liao, H.-C.; Tseng, S.-C.
2018-05-01
Injection molding of thin slender parts is often complicated by core deflection. This deflection is caused by molten plastics race tracking through the slit between the core and the rigid cavity wall. The pressure of this liquid exerts a lateral force of the slender core causing the core to bend, and this bending is governed by a nonlinear fifth order ordinary differential equation for the deflection that is not directly in the position along the core. Here we subject this differential equation to 6 sets of boundary conditions, corresponding to 6 commercial core constraints. For each such set of boundary conditions, we develop an explicit approximate analytical solution, including both a linear term and a nonlinear term. By comparison with finite difference solutions, we find our new analytical solutions to be accurate. We then use these solutions to derive explicit analytical approximations for maximum deflections and for the core position of these maximum deflections. Our experiments on the base-gated free-tip boundary condition agree closely with our new explicit approximate analytical solution.
Deployment, Foam Rigidization, and Structural Characterization of Inflatable Thin-Film Booms
NASA Technical Reports Server (NTRS)
Schnell, Andrew R.; Leigh, Larry M., Jr.; Tinker, Michael L.; McConnaughey, Paul R. (Technical Monitor)
2002-01-01
Detailed investigation of the construction, packaging/deployment, foam rigidization, and structural characterization of polyimide film inflatable booms is described. These structures have considerable potential for use in space with solar concentrators, solar sails, space power systems including solar arrays, and other future missions. Numerous thin-film booms or struts were successfully constructed, inflated, injected with foam, and rigidized. Both solid-section and annular test articles were fabricated, using Kapton polyimide film, various adhesives, Styrofoam end plugs, and polyurethane pressurized foam. Numerous inflation/deployment experiments were conducted and compared to computer simulations using the MSC/DYTRAN code. Finite element models were developed for several foam-rigidized struts and compared to model test results. Several problems encountered in the construction, deployment, and foam injection/rigidization process are described. Areas of difficulty included inadequate adhesive strength, cracking of the film arid leakage, excessive bending of the structure during deployment, problems with foam distribution and curing properties, and control of foam leakage following injection into the structure. Many of these problems were overcome in the course of the research.
Nevalainen, T J; Gavin, J B; Seelye, R N; Whitehouse, S; Donnell, M
1978-07-01
The effect of normal and artificially induced rigor mortis on the vascular passage of erythrocytes and fluid through isolated dog hearts was studied. Increased rigidity of 6-mm thick transmural sections through the centre of the posterior papillary muscle was used as an indication of rigor. The perfusibility of the myocardium was tested by injecting 10 ml of 1% sodium fluorescein in Hanks solution into the circumflex branch of the left coronary artery. In prerigor hearts (20 minute incubation) fluorescein perfused the myocardium evenly whether or not it was preceded by an injection of 10 ml of heparinized dog blood. Rigor mortis developed in all hearts after 90 minutes incubation or within 20 minutes of perfusing the heart with 50 ml of 5 mM iodoacetate in Hanks solution. Fluorescein injected into hearts in rigor did not enter the posterior papillary muscle and adjacent subendocardium whether or not it was preceded by heparinized blood. Thus the vascular occlusion caused by rigor in the dog heart appears to be so effective that it prevents flow into the subendocardium of small soluble ions such as fluorescein.
Bohic, S; Weiss, P; Roger, P; Daculsi, G
2001-03-01
Hydroxypropylmethylcellulose (HPMC) is used as a ligand for a bioactive calcium phosphate ceramic (the filler) in a ready-to-use injectable sterilized biomaterial for bone and dental surgery. Light scattering experiments were usually used to study high water-soluble polymers and to determine the basic macromolecular parameters. In order to gain a deeper understanding of polymer/mineral interactions in this type of material, we have investigated the effect of divalent and trivalent ions (Ca(2+), PO(4)(3-)) and steam sterilization on dilute solutions of HPMC and hydroxyethylcellulose (HEC). The sterilization process may cause some degradation of HEC taking into account its high molecular weight and some rigidity of the polymer chain. Moreover, in the case of HPMC, the changes in the conformations rather than degradation process are supposed. These effects of degradation and flocculation are strengthened in alkaline medium. Experimental data suggested the formation of chelate complexes between Ca(2+) and HPMC which improve its affinity to the mineral blend and consolidate the injectable biomaterial even in the case of its hydration by biological fluid. Copyright 2001 Kluwer Academic Publishers
NASA Astrophysics Data System (ADS)
Smith, David Eugene
Little basic research has been reported on the physical structure of aqueous solutions of saccharides. Sound velocimeters can be used to study physical structure of solutions, non-destructively. The La Place relationship was used to calculate adiabatic compressibility values for solutions from experimentally determined values for sound velocity and density. Using a sound velocimeter, aqueous solutions of twelve alditols and saccharides were studied at various concentrations and temperatures. Data indicated that over most of the temperature range employed (20 to 70 C) adiabatic compressibility of the solutions was the dominant factor in defining sound velocity through and structural rigidity of solution. As concentration of solute increased, more rigid structures were formed in solution, which caused sound velocity values to increase with increasing concentrations of solute; maximum sound velocity values were obtained at progressively lower temperatures. Analysis of data for sound velocity, density and adiabatic compressibility of various solutions provided partial insight into effects of each solute molecule on structure of solutions. A furanose form in a monosaccharide contributed to a more rigid structure than did a pyranose ring when below 30C. At higher temperatures the pyranose ring provided more rigidity than did the furanose ring. Hydroxyl groups in the equatorial position generally contributed more to rigidity of structure than did OH groups in axial positions. Disaccharides contributed differences from the inherent monosaccharides. A (beta) glycosidic linkage provided more structural rigidity of solution than did a linkage. Among the alditols, mannitol and sorbitol contributed very similar characteristics to solutions. Xylitol, in solution provided less rigidity, density and sound velocity than did mannitol-sorbitol in proportion to the lower molecular weight or xylitol. From the data for velocity of sound through single sugar solutions values for solutions of mixtures of these sugars at concentrations to 0.9m could be calculated with accuracy. Each sugar contributed independently to structure of solution and sound velocity values. At solute concentrations greater than 0.9m, there appeared to be some interaction among mixed solute molecules in solution.
Manny, Ted B; Hemal, Ashok K
2014-04-01
To describe the initial feasibility of fluorescence-enhanced robotic radical cystectomy (FERRC) using real-time cystoscopic injection of unconjugated indocyanine green (ICG) for tumor marking and identification of sentinel lymphatic drainage with additional intravenous injection for mesenteric angiography. Ten patients with clinically localized high-grade bladder cancer underwent FERRC. Before robot docking, rigid cystoscopy was performed, during which a 2.5-mg/mL ICG solution was injected in the bladder submucosa and detrusor circumferentially around the tumor. After robot docking, parameters describing the time course of tissue fluorescence and pelvic lymphangiography were systematically recorded. Lymphatic packets containing fluorescent lymph nodes were considered the sentinel drainage. Eight patients underwent intracorporeal ileal conduit urinary diversion, during which an additional 2-mL ICG solution was given intravenously for mesenteric angiography, allowing maximal preservation of bowel vascularity to the conduit and remaining bowel segments. Bladder tumor marking and identification of sentinel drainage were achieved in 9 of 10 (90%) patients. The area of bladder tumor was identified at a median of 15 minutes after injection, whereas sentinel drainage was visualized at a median of 30 minutes. Mesenteric angiography was successful in 8 of 8 (100%) patients at a median time of <1 minutes after intravenous injection and enabled identification of bowel arcades before intracorporeal bowel stapling. FERRC using combined cystoscopic and intravenous injection of ICG is safe and feasible. FERRC allows for reliable bladder tumor marking, identification of sentinel lymphatic drainage, and identification of mesenteric vasculature in most patients. Copyright © 2014 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Kia, T.; Longuski, J. M.
1984-01-01
Analytic error bounds are presented for the solutions of approximate models for self-excited near-symmetric rigid bodies. The error bounds are developed for analytic solutions to Euler's equations of motion. The results are applied to obtain a simplified analytic solution for Eulerian rates and angles. The results of a sample application of the range and error bound expressions for the case of the Galileo spacecraft experiencing transverse torques demonstrate the use of the bounds in analyses of rigid body spin change maneuvers.
Botulinum toxin in myotonia congenita: it does not help against rigidity and pain.
Dressler, Dirk; Adib Saberi, Fereshte
2014-05-01
Botulinum toxin (BT) is a potent local muscle relaxant with analgetic properties. Myotonia congenita (MC) is a genetic disorder producing muscle rigidity and pain. BT injected into the trapezius produced mild paresis, but no effect on rigidity and pain. There were no signs of systemic effects. Lack of BT efficacy on MC rigidity confirms its origin from muscle membrane dysfunction rather than from inappropriate neuromuscular activation. Lack of BT efficacy on pain could be caused by lack of anti-rigidity effect. It could also be due to separate non-muscular pain mechanisms unresponsive to BT.
NONUNIFORM FOURIER TRANSFORMS FOR RIGID-BODY AND MULTI-DIMENSIONAL ROTATIONAL CORRELATIONS
BAJAJ, CHANDRAJIT; BAUER, BENEDIKT; BETTADAPURA, RADHAKRISHNA; VOLLRATH, ANTJE
2013-01-01
The task of evaluating correlations is central to computational structural biology. The rigid-body correlation problem seeks the rigid-body transformation (R, t), R ∈ SO(3), t ∈ ℝ3 that maximizes the correlation between a pair of input scalar-valued functions representing molecular structures. Exhaustive solutions to the rigid-body correlation problem take advantage of the fast Fourier transform to achieve a speedup either with respect to the sought translation or rotation. We present PFcorr, a new exhaustive solution, based on the non-equispaced SO(3) Fourier transform, to the rigid-body correlation problem; unlike previous solutions, ours achieves a combination of translational and rotational speedups without requiring equispaced grids. PFcorr can be straightforwardly applied to a variety of problems in protein structure prediction and refinement that involve correlations under rigid-body motions of the protein. Additionally, we show how it applies, along with an appropriate flexibility model, to analogs of the above problems in which the flexibility of the protein is relevant. PMID:24379643
The problem of exact interior solutions for rotating rigid bodies in general relativity
NASA Technical Reports Server (NTRS)
Wahlquist, H. D.
1993-01-01
The (3 + 1) dyadic formalism for timelike congruences is applied to derive interior solutions for stationary, axisymmetric, rigidly rotating bodies. In this approach the mathematics is formulated in terms of three-space-covariant, first-order, vector-dyadic, differential equations for a and Omega, the acceleration and angular velocity three-vectors of the rigid body; for T, the stress dyadic of the matter; and for A and B, the 'electric' and 'magnetic' Weyl curvature dyadics which describe the gravitational field. It is shown how an appropriate ansatz for the forms of these dyadics can be used to discover exact rotating interior solutions such as the perfect fluid solution first published in 1968. By incorporating anisotropic stresses, a generalization is found of that previous solution and, in addition, a very simple new solution that can only exist in toroidal configurations.
A microbial trigger for gelled polymers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bailey, S.; Bryant, R.; Zhu, T.
1995-12-31
A process using a microbially gelled biopolymer was developed and used to modify permeability in coreflood experiments. Alkaline-soluble curdlan biopolymer was mixed with microbial nutrients and acid-producing alkaliphilic bacteria, and injected into Berea sandstone cores. Concurrent bottle tests with the polymer solution were incubated beside the core. Polymer in the bottle tests formed rigid gel in 2-5 days at 27{degree}C. After 7 days incubation, 25-35 psi fluid pressure was required to begin flow through the cores. Permeability of the cores was decreased from 852 md to 2.99 md and from 904 md to 4.86 md, respectively, giving residual resistance factorsmore » of 334 and 186.« less
Phosphorescence and Energy Transfer in Rigid Solutions.
ERIC Educational Resources Information Center
Enciso, E.; Cabello, A.
1980-01-01
Describes an experiment which illustrates the general aspects of intermolecular energy transfer between triplet states in rigid solutions of organic compounds solved in an ethanol-ether mixture. Measurements of quenching and energy transfer processes are made using the chemicals of benzophenone and naphthalene. (CS)
Bending spring rate investigation of nanopipette for cell injection.
Shen, Yajing; Zhang, Zhenhai; Fukuda, Toshio
2015-04-17
Bending of nanopipette tips during cell penetration is a major cause of cell injection failure. However, the flexural rigidity of nanopipettes is little known due to their irregular structure. In this paper, we report a quantitative method to estimate the flexural rigidity of a nanopipette by investigating its bending spring rate. First nanopipettes with a tip size of 300 nm are fabricated from various glass tubes by laser pulling followed by focused ion beam (FIB) milling. Then the bending spring rate of the nanopipettes is investigated inside a scanning electron microscope (SEM). Finally, a yeast cell penetration test is performed on these nanopipettes, which have different bending spring rates. The results show that nanopipettes with a higher bending spring rate have better cell penetration capability, which confirms that the bending spring rate may well reflect the flexural rigidity of a nanopipette. This method provides a quantitative parameter for characterizing the mechanical property of a nanopipette that can be potentially taken as a standard specification in the future. This general method can also be used to estimate other one-dimensional structures for cell injection, which will greatly benefit basic cell biology research and clinical applications.
Bending spring rate investigation of nanopipette for cell injection
NASA Astrophysics Data System (ADS)
Shen, Yajing; Zhang, Zhenhai; Fukuda, Toshio
2015-04-01
Bending of nanopipette tips during cell penetration is a major cause of cell injection failure. However, the flexural rigidity of nanopipettes is little known due to their irregular structure. In this paper, we report a quantitative method to estimate the flexural rigidity of a nanopipette by investigating its bending spring rate. First nanopipettes with a tip size of 300 nm are fabricated from various glass tubes by laser pulling followed by focused ion beam (FIB) milling. Then the bending spring rate of the nanopipettes is investigated inside a scanning electron microscope (SEM). Finally, a yeast cell penetration test is performed on these nanopipettes, which have different bending spring rates. The results show that nanopipettes with a higher bending spring rate have better cell penetration capability, which confirms that the bending spring rate may well reflect the flexural rigidity of a nanopipette. This method provides a quantitative parameter for characterizing the mechanical property of a nanopipette that can be potentially taken as a standard specification in the future. This general method can also be used to estimate other one-dimensional structures for cell injection, which will greatly benefit basic cell biology research and clinical applications.
NASA Technical Reports Server (NTRS)
Mayo, Wilbur L
1952-01-01
Solutions of impact of a rigid prismatic float connected by a massless spring to a rigid upper mass are presented. The solutions are based on hydrodynamic theory which has been experimentally confirmed for a rigid structure. Equations are given for defining the spring constant and the ratio of the sprung mass to the lower mass so that the two-mass system provides representation of the fundamental mode of an airplane wing. The forces calculated are more accurate than the forces which would be predicted for a rigid airframe since the effect of the fundamental mode on the hydrodynamic force is taken into account. In a comparison of the theoretical data with data for a severe flight-test landing impact, the effect of the fundamental mode on the hydrodynamic force is considered and response data are compared with experimental data.
A computational procedure for multibody systems including flexible beam dynamics
NASA Technical Reports Server (NTRS)
Downer, J. D.; Park, K. C.; Chiou, J. C.
1990-01-01
A computational procedure suitable for the solution of equations of motions for flexible multibody systems has been developed. A fully nonlinear continuum approach capable of accounting for both finite rotations and large deformations has been used to model a flexible beam component. The beam kinematics are referred directly to an inertial reference frame such that the degrees of freedom embody both the rigid and flexible deformation motions. As such, the beam inertia expression is identical to that of rigid body dynamics. The nonlinear coupling between gross body motion and elastic deformation is contained in the internal force expression. Numerical solution procedures for the integration of spatial kinematic systems can be directily applied to the generalized coordinates of both the rigid and flexible components. An accurate computation of the internal force term which is invariant to rigid motions is incorporated into the general solution procedure.
Lim, Ju Hyun; You, Dalsan; Jeong, In Gab; Park, Hyung Keun; Ahn, Hanjong; Kim, Choung-Soo
2013-10-01
Vesicourethral anastomotic urine leak is a common postoperative complication of radical prostatectomy. Herein we describe a novel method for the treatment of this complication. Intervention for a prolonged or massive anastomotic urine leak was required in 10 out of 1828 patients (0.5%) submitted to radical prostatectomy between 2007 and 2011. N-butyl-2-cyanoacrylate (Histoacryl) followed by fibrin glue (Greenplast) were injected under local anesthesia into vesicourethral anastomotic gaps under fluoroscopic guidance using a 20-Fr rigid cystoscope. Cystograms were taken in all patients to confirm complete urine leak resolution before the removal of the urethral catheter. Cystoscopic injection of Histoacryl followed by fibrin glue was technically successful and well tolerated in all patients. The mean time from radical prostatectomy to glue injection was 16.0 days (range 12-27 days). Urethral catheterization was required for an average of 7.7 days after cystoscopic injection of fibrin glue (range 3-13 days). These measures ultimately enabled complete resolution of the urine leak in all cases. At a mean follow up of 23.3 months, all 10 patients were fully continent. The mean time to recovery of urinary continence was 20.4 weeks (range 3.9-60.0 weeks). Cystoscopic injection of N-butyl-2-cyanoacrylate followed by fibrin glue into the anastomotic gap is both a feasible and effective solution in patients with a persistent or massive vesicourethral anastomotic urine leak after radical prostatectomy. © 2013 The Japanese Urological Association.
A boundary integral approach to the scattering of nonplanar acoustic waves by rigid bodies
NASA Technical Reports Server (NTRS)
Gallman, Judith M.; Myers, M. K.; Farassat, F.
1990-01-01
The acoustic scattering of an incident wave by a rigid body can be described by a singular Fredholm integral equation of the second kind. This equation is derived by solving the wave equation using generalized function theory, Green's function for the wave equation in unbounded space, and the acoustic boundary condition for a perfectly rigid body. This paper will discuss the derivation of the wave equation, its reformulation as a boundary integral equation, and the solution of the integral equation by the Galerkin method. The accuracy of the Galerkin method can be assessed by applying the technique outlined in the paper to reproduce the known pressure fields that are due to various point sources. From the analysis of these simpler cases, the accuracy of the Galerkin solution can be inferred for the scattered pressure field caused by the incidence of a dipole field on a rigid sphere. The solution by the Galerkin technique can then be applied to such problems as a dipole model of a propeller whose pressure field is incident on a rigid cylinder. This is the groundwork for modeling the scattering of rotating blade noise by airplane fuselages.
Fromow-Guerra, Jans; Solís-Vivanco, Adriana; Perez-Reguera, Adriana; Quiroz-Mercado, Hugo; Meza-de Regil, Armando; Papa-Oliva, Gabriela; Morales-Cantón, Virgilio
2016-01-01
The aim of this study is to assess the change in intraocular pressure after a road trip, in eyes with different levels of filling with gas tamponade. Five rabbit eyes were subject to pars plana vitrectomy and gas tamponade (filling percentage: 25%, 50%, and 100% of nonexpansile SF6, 100% saline solution, and 100% room air). A sixth eye was injected with 0.35 cc of undiluted SF6 without vitrectomy. Guided by global positioning system, they were driven to the highest point of the highway connecting Mexico City with Puebla city and back, stopping every 300 m to assess intraocular pressure. The rabbit's scleral rigidity and estimation for human eyes were done by using the Friedenwald nomogram. Maximum altitude was 3209 m (Δ949 m). There were significant differences in intraocular pressure on the rabbit eyes filled with SF6 at 100%, 50%, 25%, and 100% room air. Per every 100 m of altitude rise, the intraocular pressure increased by 1.53, 1.0046, 0.971, and 0.97 mmHg, respectively. Using the human Friedenwald rigidity coefficient, the human eye estimate for intraocular pressure change was 2.1, 1.8, 1.4, and 1.1 mmHg per every 100 m of attitude rise. Altitude changes have a significant impact on intraocular pressure. The final effect depends on the percentage of vitreous cavity fill and scleral rigidity. PMID:27957500
Fromow-Guerra, Jans; Solís-Vivanco, Adriana; Velez-Montoya, Raul; Perez-Reguera, Adriana; Quiroz-Mercado, Hugo; Meza-de Regil, Armando; Papa-Oliva, Gabriela; Morales-Cantón, Virgilio
2016-01-01
The aim of this study is to assess the change in intraocular pressure after a road trip, in eyes with different levels of filling with gas tamponade. Five rabbit eyes were subject to pars plana vitrectomy and gas tamponade (filling percentage: 25%, 50%, and 100% of nonexpansile SF 6 , 100% saline solution, and 100% room air). A sixth eye was injected with 0.35 cc of undiluted SF 6 without vitrectomy. Guided by global positioning system, they were driven to the highest point of the highway connecting Mexico City with Puebla city and back, stopping every 300 m to assess intraocular pressure. The rabbit's scleral rigidity and estimation for human eyes were done by using the Friedenwald nomogram. Maximum altitude was 3209 m (Δ949 m). There were significant differences in intraocular pressure on the rabbit eyes filled with SF 6 at 100%, 50%, 25%, and 100% room air. Per every 100 m of altitude rise, the intraocular pressure increased by 1.53, 1.0046, 0.971, and 0.97 mmHg, respectively. Using the human Friedenwald rigidity coefficient, the human eye estimate for intraocular pressure change was 2.1, 1.8, 1.4, and 1.1 mmHg per every 100 m of attitude rise. Altitude changes have a significant impact on intraocular pressure. The final effect depends on the percentage of vitreous cavity fill and scleral rigidity.
Lee, Ming-Tsung; Vishnyakov, Aleksey; Neimark, Alexander V
2013-09-05
Micelle formation in surfactant solutions is a self-assembly process governed by complex interplay of solvent-mediated interactions between hydrophilic and hydrophobic groups, which are commonly called heads and tails. However, the head-tail repulsion is not the only factor affecting the micelle formation. For the first time, we present a systematic study of the effect of chain rigidity on critical micelle concentration and micelle size, which is performed with the dissipative particle dynamics simulation method. Rigidity of the coarse-grained surfactant molecule was controlled by the harmonic bonds set between the second-neighbor beads. Compared to flexible molecules with the nearest-neighbor bonds being the only type of bonded interactions, rigid molecules exhibited a lower critical micelle concentration and formed larger and better-defined micelles. By varying the strength of head-tail repulsion and the chain rigidity, we constructed two-dimensional diagrams presenting how the critical micelle concentration and aggregation number depend on these parameters. We found that the solutions of flexible and rigid molecules that exhibited approximately the same critical micelle concentration could differ substantially in the micelle size and shape depending on the chain rigidity. With the increase of surfactant concentration, primary micelles of more rigid molecules were found less keen to agglomeration and formation of nonspherical aggregates characteristic of flexible molecules.
Deformable image registration with local rigidity constraints for cone-beam CT-guided spine surgery
NASA Astrophysics Data System (ADS)
Reaungamornrat, S.; Wang, A. S.; Uneri, A.; Otake, Y.; Khanna, A. J.; Siewerdsen, J. H.
2014-07-01
Image-guided spine surgery (IGSS) is associated with reduced co-morbidity and improved surgical outcome. However, precise localization of target anatomy and adjacent nerves and vessels relative to planning information (e.g., device trajectories) can be challenged by anatomical deformation. Rigid registration alone fails to account for deformation associated with changes in spine curvature, and conventional deformable registration fails to account for rigidity of the vertebrae, causing unrealistic distortions in the registered image that can confound high-precision surgery. We developed and evaluated a deformable registration method capable of preserving rigidity of bones while resolving the deformation of surrounding soft tissue. The method aligns preoperative CT to intraoperative cone-beam CT (CBCT) using free-form deformation (FFD) with constraints on rigid body motion imposed according to a simple intensity threshold of bone intensities. The constraints enforced three properties of a rigid transformation—namely, constraints on affinity (AC), orthogonality (OC), and properness (PC). The method also incorporated an injectivity constraint (IC) to preserve topology. Physical experiments involving phantoms, an ovine spine, and a human cadaver as well as digital simulations were performed to evaluate the sensitivity to registration parameters, preservation of rigid body morphology, and overall registration accuracy of constrained FFD in comparison to conventional unconstrained FFD (uFFD) and Demons registration. FFD with orthogonality and injectivity constraints (denoted FFD+OC+IC) demonstrated improved performance compared to uFFD and Demons. Affinity and properness constraints offered little or no additional improvement. The FFD+OC+IC method preserved rigid body morphology at near-ideal values of zero dilatation ({ D} = 0.05, compared to 0.39 and 0.56 for uFFD and Demons, respectively) and shear ({ S} = 0.08, compared to 0.36 and 0.44 for uFFD and Demons, respectively). Target registration error (TRE) was similarly improved for FFD+OC+IC (0.7 mm), compared to 1.4 and 1.8 mm for uFFD and Demons. Results were validated in human cadaver studies using CT and CBCT images, with FFD+OC+IC providing excellent preservation of rigid morphology and equivalent or improved TRE. The approach therefore overcomes distortions intrinsic to uFFD and could better facilitate high-precision IGSS.
Overcoming the Practical Barriers to Spinal Cord Cell Transplantation for ALS
2012-10-01
ABSTRACT: This grant will provide critical data on tolerance and toxicity of cell dosing and numbers of permissible spinal cord injections. Rigorous...Surgical Technique) will provide critical data on tolerance and toxicity of cell dosing and numbers of permissible spinal cord injections. Aim 2 (Graft...connected to a rigid needle of the same gauge as the floating cannula one – Figure 7) using the maximum volume/number of injections could result in
Fabrication of injection molded sintered alpha SiC turbine components
NASA Technical Reports Server (NTRS)
Storm, R. S.; Ohnsorg, R. W.; Frechette, F. J.
1981-01-01
Fabrication of a sintered alpha silicon carbide turbine blade by injection molding is described. An extensive process variation matrix was carried out to define the optimum fabrication conditions. Variation of molding parameters had a significant impact on yield. Turbine blades were produced in a reasonable yield which met a rigid quality and dimensional specification. Application of injection molding technology to more complex components such as integral rotors is also described.
The Rigid Orthogonal Procrustes Rotation Problem
ERIC Educational Resources Information Center
ten Berge, Jos M. F.
2006-01-01
The problem of rotating a matrix orthogonally to a best least squares fit with another matrix of the same order has a closed-form solution based on a singular value decomposition. The optimal rotation matrix is not necessarily rigid, but may also involve a reflection. In some applications, only rigid rotations are permitted. Gower (1976) has…
Propagation of Finite Amplitude Sound in Multiple Waveguide Modes.
NASA Astrophysics Data System (ADS)
van Doren, Thomas Walter
1993-01-01
This dissertation describes a theoretical and experimental investigation of the propagation of finite amplitude sound in multiple waveguide modes. Quasilinear analytical solutions of the full second order nonlinear wave equation, the Westervelt equation, and the KZK parabolic wave equation are obtained for the fundamental and second harmonic sound fields in a rectangular rigid-wall waveguide. It is shown that the Westervelt equation is an acceptable approximation of the full nonlinear wave equation for describing guided sound waves of finite amplitude. A system of first order equations based on both a modal and harmonic expansion of the Westervelt equation is developed for waveguides with locally reactive wall impedances. Fully nonlinear numerical solutions of the system of coupled equations are presented for waveguides formed by two parallel planes which are either both rigid, or one rigid and one pressure release. These numerical solutions are compared to finite -difference solutions of the KZK equation, and it is shown that solutions of the KZK equation are valid only at frequencies which are high compared to the cutoff frequencies of the most important modes of propagation (i.e., for which sound propagates at small grazing angles). Numerical solutions of both the Westervelt and KZK equations are compared to experiments performed in an air-filled, rigid-wall, rectangular waveguide. Solutions of the Westervelt equation are in good agreement with experiment for low source frequencies, at which sound propagates at large grazing angles, whereas solutions of the KZK equation are not valid for these cases. At higher frequencies, at which sound propagates at small grazing angles, agreement between numerical solutions of the Westervelt and KZK equations and experiment is only fair, because of problems in specifying the experimental source condition with sufficient accuracy.
Nagakura, Manamu; Tanimoto, Yasuhiro; Nishiyama, Norihiro
2017-07-26
The use of non-metal clasp denture (NMCD) materials may seriously affect the remaining tissues because of the low rigidity of NMCD materials such as polyamides. The purpose of this study was to develop a high-rigidity glass fiber-reinforced thermoplastic (GFRTP) composed of E-glass fiber and polyamide-6 for NMCDs using an injection molding. The reinforcing effects of fiber on the flexural properties of GFRTPs were investigated using glass fiber content ranging from 0 to 50 mass%. Three-point bending tests indicated that the flexural strength and elastic modulus of a GFRTP with a fiber content of 50 mass% were 5.4 and 4.7 times higher than those of unreinforced polyamide-6, respectively. The result showed that the physical characteristics of GFRTPs were greatly improved by increasing the fiber content, and the beneficial effects of fiber reinforcement were evident. The findings suggest that the injection-molded GFRTPs are adaptable to NMCDs because of their excellent mechanical properties.
Krompecher, Thomas; Gilles, André; Brandt-Casadevall, Conception; Mangin, Patrice
2008-04-07
Objective measurements were carried out to study the possible re-establishment of rigor mortis on rats after "breaking" (mechanical solution). Our experiments showed that: *Cadaveric rigidity can re-establish after breaking. *A significant rigidity can reappear if the breaking occurs before the process is complete. *Rigidity will be considerably weaker after the breaking. *The time course of the intensity does not change in comparison to the controls: --the re-establishment begins immediately after the breaking; --maximal values are reached at the same time as in the controls; --the course of the resolution is the same as in the controls.
NASA Technical Reports Server (NTRS)
Fleischer, G. E.; Likins, P. W.
1975-01-01
Three computer subroutines designed to solve the vector-dyadic differential equations of rotational motion for systems that may be idealized as a collection of hinge-connected rigid bodies assembled in a tree topology, with an optional flexible appendage attached to each body are reported. Deformations of the appendages are mathematically represented by modal coordinates and are assumed small. Within these constraints, the subroutines provide equation solutions for (1) the most general case of unrestricted hinge rotations, with appendage base bodies nominally rotating at a constant speed, (2) the case of unrestricted hinge rotations between rigid bodies, with the restriction that those rigid bodies carrying appendages are nominally nonspinning, and (3) the case of small hinge rotations and nominally nonrotating appendages. Sample problems and their solutions are presented to illustrate the utility of the computer programs.
NASA Astrophysics Data System (ADS)
Wilson, F.; Neukirch, T.
2018-01-01
We present new analytical three-dimensional solutions of the magnetohydrostatic equations, which are applicable to the co-rotating frame of reference outside a rigidly rotating cylindrical body, and have potential applications to planetary magnetospheres and stellar coronae. We consider the case with centrifugal force only, and use a transformation method in which the governing equation for the "pseudo-potential" (from which the magnetic field can be calculated) becomes the Laplace partial differential equation. The new solutions extend the set of previously found solutions to those of a "fractional multipole" nature, and offer wider possibilities for modelling than before. We consider some special cases, and present example solutions.
NASA Astrophysics Data System (ADS)
Reaungamornrat, S.; Wang, A. S.; Uneri, A.; Otake, Y.; Zhao, Z.; Khanna, A. J.; Siewerdsen, J. H.
2014-03-01
Purpose: Deformable registration of preoperative and intraoperative images facilitates accurate localization of target and critical anatomy in image-guided spine surgery. However, conventional deformable registration fails to preserve the morphology of rigid bone anatomy and can impart distortions that confound high-precision intervention. We propose a constrained registration method that preserves rigid morphology while allowing deformation of surrounding soft tissues. Method: The registration method aligns preoperative 3D CT to intraoperative cone-beam CT (CBCT) using free-form deformation (FFD) with penalties on rigid body motion imposed according to a simple intensity threshold. The penalties enforced 3 properties of a rigid transformation - namely, constraints on affinity (AC), orthogonality (OC), and properness (PC). The method also incorporated an injectivity constraint (IC) to preserve topology. Physical experiments (involving phantoms, an ovine spine, and a human cadaver) as well as digital simulations were performed to evaluate the sensitivity to registration parameters, preservation of rigid body morphology, and overall registration accuracy of constrained FFD in comparison to conventional unconstrained FFD (denoted uFFD) and Demons registration. Result: FFD with orthogonality and injectivity constraints (denoted FFD+OC+IC) demonstrated improved performance compared to uFFD and Demons. Affinity and properness constraints offered little or no additional improvement. The FFD+OC+IC method preserved rigid body morphology at near-ideal values of zero dilatation (D = 0.05, compared to 0.39 and 0.56 for uFFD and Demons, respectively) and shear (S = 0.08, compared to 0.36 and 0.44 for uFFD and Demons, respectively). Target registration error (TRE) was similarly improved for FFD+OC+IC (0.7 mm), compared to 1.4 and 1.8 mm for uFFD and Demons. Results were validated in human cadaver studies using CT and CBCT images, with FFD+OC+IC providing excellent preservation of rigid morphology and equivalent or improved TRE. Conclusions: A promising method for deformable registration in CBCT-guided spine surgery has been identified incorporating a constrained FFD to preserve bone morphology. The approach overcomes distortions intrinsic to unconstrained FFD and could better facilitate high-precision image-guided spine surgery.
Xuan, Xu-Jun; Bai, Gang; Zhang, Cai-Xia; Xu, Chao; Lu, Fu-Ding; Peng, Yang; Ma, Gang; Han, Cong-Hui; Chen, Jun
2016-01-01
We aim to investigate the correlations between hemodynamic parameters, penile rigidity grading, and the therapeutic effects of phosphodiesterase type 5 inhibitors using color Doppler flow imaging after intracavernosal injection in patients with erectile dysfunction. This study involved 164 patients. After intracavernosal injection with a mixture of papaverine (60 mg), prostaglandin E1 (10 μg), and lidocaine (2%, 0.5–1 ml), the penile vessels were assessed using color Doppler flow imaging. Penile rigidity was classified based on the Erection Hardness Score system as Grades 4, 3, 2 or 1 (corresponding to Schramek Grades V to II). Then, the patients were given oral sildenafil (50–100 mg) and scored according to the International Index of Erectile Function (IIEF-5) questionnaire. The number of patients with penile rigidities of Schramek Grades II to V was 14, 18, 21, and 111, respectively. The IIEF-5 score was positively correlated with the refilling index of the penile cavernosal artery (r = 0.79, P < 0.05), the peak systolic velocity (r = 0.45, P < 0.05), and penile rigidity (r = 0.75, P < 0.05), and was negatively correlated with the end diastolic velocity (r = −0.74, P < 0.05). For patients with erectile dysfunction, both the IIEF-5 score after sildenafil administration, which is correlated with penile rigidity, and the hemodynamic parameters detected using color Doppler flow imaging may predict the effects of phosphodiesterase type 5 inhibitor treatment and could provide a reasonable model for the targeted-treatment of erectile dysfunction. PMID:25994651
Study on In-mold Punching during PPS/GF Injection Molding
NASA Astrophysics Data System (ADS)
Inuzuka, Takayuki; Fujita, Akihiro; Nakai, Asami; Hamada, Hiroyuki
The influence of the punching condition on strength and the amount of shear droop was investigated to optimize the processing condition for punching in the mold during glass fiber reinforced polyphenylenesulfide (PPS/GF) injection molding. For in-mold punching part during cooling process, the tensile strength was constant because the pressure loss by the punch did not occur. The amount of the shear droop decreased in line with the increase in delay time because the rigidity of injection molded part in the mold increased when the resin was cooled. Moreover, when the resin temperature lowered more than the glass transition temperature, the amount of the shear droop was constant because the rigidity became constant. It is necessary to begin punching when the resin temperature lowers more than the glass transition temperature after holding pressure process is completed, to secure high strength and to assume 0.05 mm or less, at which level the shear droop cannot be visually recognized. The shortest delay time for PPS/GF is 8 sec. The delay time to minimize the amount of the shear droop can be guessed by analyzing the temperature change of the resin in the mold by injection molding CAE.
Efficacy of multipurpose solutions for rigid gas permeable lenses.
Boost, Maureen; Cho, Pauline; Lai, Sindy
2006-09-01
The use of multipurpose solutions for cleaning and disinfecting rigid gas permeable lenses has replaced single purpose solutions, but there are no reports of the efficacy of these multipurpose solutions, or of the effects of storage conditions on their disinfecting capacities. This study investigated activity against four bacterial and two fungal species, and the effects of storage in a refrigerator, at room temperature, at elevated temperature in both dry and humid conditions and with exposure to sunlight. The disinfecting solutions were challenged with the micro-organisms initially upon opening and then at 2-weekly intervals up to 12 weeks after being stored under the different conditions. Solutions were opened daily to simulate use. One solution failed to meet Food and Drug Administration (FDA) criteria to reduce numbers of bacteria by three log dilutions and of fungi by one log dilution. Storage reduced activity of all solutions over the 12-week period, but not below the requirements of the FDA. Storage in the refrigerator tended to reduce disinfecting capacity more quickly. Multipurpose solutions for rigid gas permeable (RGP) lenses lose activity over the 3 months recommended time of use but remain satisfactory for use over this time in the conditions tested. Practitioners need to remind patients to replace their solutions regularly and should advise against storage in the refrigerator. Multipurpose solutions for RGP lenses have simplified cleaning and disinfecting processes and the current formulations have improved disinfecting capacity compared to former disinfecting solutions, which is particularly important for wearers of orthokeratology lenses.
Ri, Hyun Su; Kim, Tae Kyun; Baik, Seung Wan; Yoon, Ji Uk; Byeon, Gyeong Jo
2011-01-01
Background Etomidate frequently induces myoclonus when administered intravenously with bolus injection during anesthetic induction. This can be bothersome for the anesthesiologist. The dose of remifentanil appropriate for preventing myoclonus without side effects was investigated. Methods All patients with American Society of Anesthesiologists (ASA) physical status I-III were divided into three groups (n = 33 per group) according to the pretreatment effect site concentration of remifentanil (Ultiva, Glaxo-Wellcome, München, Germany) of 0, 2 or 4 ng/ml (Group N: 0 ng/ml, Group R: 2 ng/ml, Group Q: 4 ng/ml) by a target controlled infusion (TCI) system. After a 0.3 mg/kg dose of etomidate was injected intravenously for over 1 minute for anesthetic induction, myoclonus was observed. Before the etomidate injection, the patients were pretreated with remifentanil and their side effects were monitored. Results The number of patients showing myoclonus was significantly different among the groups. The incidence of myoclonus was 81%, 12% and 0% (groups N, R, and Q, respectively, P < 0.01). Side effects including bradycardia and hypotension did not occur in either Group R or Q. Chest wall rigidity occured in 45% of patients in Group Q. Conclusions Administration with a 2 ng/ml effect site concentration of remifentanil could reduce the incidence of myoclonus caused by etomidate bolus injection without chest wall rigidity. PMID:21927682
Prytkova, Vera; Heyden, Matthias; Khago, Domarin; Freites, J Alfredo; Butts, Carter T; Martin, Rachel W; Tobias, Douglas J
2016-08-25
We present a novel multi-conformation Monte Carlo simulation method that enables the modeling of protein-protein interactions and aggregation in crowded protein solutions. This approach is relevant to a molecular-scale description of realistic biological environments, including the cytoplasm and the extracellular matrix, which are characterized by high concentrations of biomolecular solutes (e.g., 300-400 mg/mL for proteins and nucleic acids in the cytoplasm of Escherichia coli). Simulation of such environments necessitates the inclusion of a large number of protein molecules. Therefore, computationally inexpensive methods, such as rigid-body Brownian dynamics (BD) or Monte Carlo simulations, can be particularly useful. However, as we demonstrate herein, the rigid-body representation typically employed in simulations of many-protein systems gives rise to certain artifacts in protein-protein interactions. Our approach allows us to incorporate molecular flexibility in Monte Carlo simulations at low computational cost, thereby eliminating ambiguities arising from structure selection in rigid-body simulations. We benchmark and validate the methodology using simulations of hen egg white lysozyme in solution, a well-studied system for which extensive experimental data, including osmotic second virial coefficients, small-angle scattering structure factors, and multiple structures determined by X-ray and neutron crystallography and solution NMR, as well as rigid-body BD simulation results, are available for comparison.
Solution structure of an antifreeze protein CfAFP-501 from Choristoneura fumiferana.
Li, Congmin; Guo, Xianrong; Jia, Zongchao; Xia, Bin; Jin, Changwen
2005-07-01
Antifreeze proteins (AFPs) are widely employed by various organisms as part of their overwintering survival strategy. AFPs have the unique ability to suppress the freezing point of aqueous solution and inhibit ice recrystallization through binding to the ice seed crystals and restricting their growth. The solution structure of CfAFP-501 from spruce budworm has been determined by NMR spectroscopy. Our result demonstrates that CfAFP-501 retains its rigid and highly regular structure in solution. Overall, the solution structure is similar to the crystal structure except the N- and C-terminal regions. NMR spin-relaxation experiments further indicate the overall rigidity of the protein and identify a collection of residues with greater flexibilities. Furthermore, Pro91 shows a cis conformation in solution instead of the trans conformation determined in the crystal structure.
Three-Axis Time-Optimal Attitude Maneuvers of a Rigid-Body
NASA Astrophysics Data System (ADS)
Wang, Xijing; Li, Jisheng
With the development trends for modern satellites towards macro-scale and micro-scale, new demands are requested for its attitude adjustment. Precise pointing control and rapid maneuvering capabilities have long been part of many space missions. While the development of computer technology enables new optimal algorithms being used continuously, a powerful tool for solving problem is provided. Many papers about attitude adjustment have been published, the configurations of the spacecraft are considered rigid body with flexible parts or gyrostate-type systems. The object function always include minimum time or minimum fuel. During earlier satellite missions, the attitude acquisition was achieved by using the momentum ex change devices, performed by a sequential single-axis slewing strategy. Recently, the simultaneous three-axis minimum-time maneuver(reorientation) problems have been studied by many researchers. It is important to research the minimum-time maneuver of a rigid spacecraft within onboard power limits, because of potential space application such as surveying multiple targets in space and academic value. The minimum-time maneuver of a rigid spacecraft is a basic problem because the solutions for maneuvering flexible spacecraft are based on the solution to the rigid body slew problem. A new method for the open-loop solution for a rigid spacecraft maneuver is presented. Having neglected all perturbation torque, the necessary conditions of spacecraft from one state to another state can be determined. There is difference between single-axis with multi-axis. For single- axis analytical solution is possible and the switching line passing through the state-space origin belongs to parabolic. For multi-axis, it is impossible to get analytical solution due to the dynamic coupling between the axes and must be solved numerically. Proved by modern research, Euler axis rotations are quasi-time-optimal in general. On the basis of minimum value principles, a research for reorienting an inertial syrnmetric spacecraft with time cost function from an initial state of rest to a final state of rest is deduced. And the solution to it is stated below: Firstly, the essential condition for solving the problem is deduced with the minimum value principle. The necessary conditions for optimality yield a two point boundary-value problem (TPBVP), which, when solved, produces the control history that minimize time performance index. In the nonsingular control, the solution is the' bang-bang maneuver. The control profile is characterized by Saturated controls for the entire maneuver. The singular control maybe existed. It is only singular in mathematics. According to physical principle, the bigger the mode of the control torque is, the shorter the time is. So saturated controls are used in singular control. Secondly, the control parameters are always in maximum, so the key problem is to determine switch point thus original problem is changed to find the changing time. By the use of adjusting the switch on/off time, the genetic algorithm, which is a new robust method is optimized to determine the switch features without the gyroscopic coupling. There is improvement upon the traditional GA in this research. The homotopy method to find the nonlinear algebra is based on rigorous topology continuum theory. Based on the idea of the homotopy, the relaxation parameters are introduced, and the switch point is figured out with simulated annealing. Computer simulation results using a rigid body show that the new method is feasible and efficient. A practical method of computing approximate solutions to the time-optimal control- switch times for rigid body reorientation has been developed.
Non-rigid Earth rotation series
NASA Astrophysics Data System (ADS)
Pashkevich, V. V.
2008-04-01
The last years a lot of attempts to derive a high-precision theory of the non-rigid Earth rotation was carried out. For these purposes the different transfer functions are used. Usually these transfer func- tions are applied to the series representing the nutation in longitude and in obliquity of the rigid Earth rotation with respect to the ecliptic of date. The aim of this investigation is a construction of the new high- precision non-rigid Earth rotation series (SN9000), dynamically adequate to the DE404/LE404 ephemeris over 2000 years, which are expressed as a function of Euler angles ψ, θ and φ with respect to the fixed ecliptic plane and equinox J2000.0. The early stages of the previous investigation: 1. The high-precision numerical solution of the rigid Earth rotation have been constructed (V.V.Pashkevich, G.I.Eroshkin and A.Brzezinski, 2004), (V.V.Pashkevich and G.I.Eroshkin, Proceedings of Journees 2004). The initial con- ditions have been calculated from SMART97 (P.Bretagnon, G.Francou, P.Rocher, J.L.Simon,1998). The discrepancies between the numerical solution and the semi-analytical solution SMART97 were obtained in Euler angles over 2000 years with one-day spacing. 2. Investigation of the discrepancies is carried out by the least squares and by the spectral analysis algorithms (V.V.Pashkevich and G.I.Eroshkin, Proceedings of Journees 2005). The high-precision rigid Earth rotation series S9000 are determined (V.V.Pashkevich and G.I.Eroshkin, 2005 ). The next stage of this investigation: 3. The new high-precision non-rigid Earth rotation series (SN9000), which are expressed as a function of Euler angles, are constructed by using the method (P.Bretagnon, P.M.Mathews, J.-L.Simon: 1999) and the transfer function MHB2002 (Mathews, P. M., Herring, T. A., and Buffett B. A., 2002).
Jiang, Nan; Ma, Jing
2011-09-12
The proton-binding behavior of solvated tetraamido/diamino quaternized macrocyclic compounds with rigid phenyl and flexible phenyl bridges in the absence or presence of an external electric field is investigated by molecular dynamics simulation. The proton can be held through H-bonding interactions with the two carbonyl oxygen atoms in macrocycles containing rigid (phenyl) and flexible (propyl) bridges. The solute-solvent H-bonding interactions cause the macrocyclic backbones to twist to different extents, depending on the different bridges. The macrocycle with the rigid phenyl linkages folds into a cuplike shape due to π-π interaction, while the propyl analogue still maintains the ellipsoidal ringlike shape with just a slight distortion. The potential energy required for proton transfer is larger in the phenyl-containing macrocycle than in the compound with propyl units. When an external electric field with a strength of 2.5 V nm(-1) is exerted along the carbonyl oxygen atoms, a difference in proton encircling is exhibited for macrocycles with rigid and flexible bridges. In contrast to encapsulation of a proton in the propyl analogue, the intermolecular solute-solvent H-bonding and intramolecular π-π stacking between the two rigid phenyl spacers leads to loss of the proton from the highly distorted cuplike macrocycle with phenyl bridges. The competition between intra- and intermolecular interactions governs the behavior of proton encircling in macrocycles. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Hierarchical Structure in Polymeric Solids and Its Influence on Properties
1989-05-01
consequences for the systematic design of phase behaviour. Also it is one of the several illustrations that the ’rigid’ group in itself need not...identified the factors controlling mesogen (or in general, rigid group ) packing in segmented LCP forming polymers and its influence on layer formation at...molecules in solution and controlled preparation of model systems" in Rigid Rod Polymers, Materials Research Publication, Ed. W. Adams, in the press
Steady state solutions to dynamically loaded periodic structures
NASA Technical Reports Server (NTRS)
Kalinowski, A. J.
1980-01-01
The general problem of solving for the steady state (time domain) dynamic response (i.e., NASTRAN rigid format-8) of a general elastic periodic structure subject to a phase difference loading of the type encountered in traveling wave propagation problems was studied. Two types of structural configurations were considered; in the first type, the structure has a repeating pattern over a span that is long enough to be considered, for all practical purposes, as infinite; in the second type, the structure has structural rotational symmetry in the circumferential direction. The theory and a corresponding set of DMAP instructions which permits the NASTRAN user to automatically alter the rigid format-8 sequence to solve the intended class of problems are presented. Final results are recovered as with any ordinary rigid format-8 solution, except that the results are only printed for the typical periodic segment of the structure. A simple demonstration problem having a known exact solution is used to illustrate the implementation of the procedure.
Ferré, J C; Chevalier, C; Robert, R; Degrez, J; Le Cloarec, A Y; Legoux, R; Orio, E; Barbin, J Y
1989-01-01
Using thick sections of the base of the skull and face their mechanical structure is viewed from the engineering aspect and the anatomic solutions evolved are compared with those selected by Aerospatiale engineers for the concept and development of the Airbus. It is concluded that the anterior and middle cranial fossae, together with the face, constitute an inseparable mechanical assembly each of whose component units participate in the rigidity of the others. Since this mechanical assembly must provide maximal rigidity for minimal weight, this suggests that aeronautical solutions should throw much light on the detail of construction of the skull and face. Indeed, the rigidity and lightness of the latter are obtained by means of solutions familiar in aeronautics: the reliance on thin-shelled beams with a honeycomb filling, the diploe analogous to a preconstrained composite or sandwich structure, a system of frames, struts and stiffeners, and the use of fillets at the sites of junction of struts.
Development of a model of space station solar array
NASA Technical Reports Server (NTRS)
Bosela, Paul A.
1990-01-01
Space structures, such as the space station solar arrays, must be extremely lightweight, flexible structures. Accurate prediction of the natural frequencies and mode shapes is essential for determining the structural adequacy of components, and designing a control system. The tension preload in the blanket of photovoltaic solar collectors, and the free/free boundary conditions of a structure in space, causes serious reservations on the use of standard finite element techniques of solution. In particular, a phenomena known as grounding, or false stiffening, of the stiffness matrix occurs during rigid body rotation. The grounding phenomena is examined in detail. Numerous stiffness matrices developed by others are examined for rigid body rotation capability, and found lacking. Various techniques are used for developing new stiffness matrices from the rigorous solutions of the differential equations, including the solution of the directed force problem. A new directed force stiffness matrix developed by the author provides all the rigid body capabilities for the beam in space.
Analytical Methods of Decoupling the Automotive Engine Torque Roll Axis
NASA Astrophysics Data System (ADS)
JEONG, TAESEOK; SINGH, RAJENDRA
2000-06-01
This paper analytically examines the multi-dimensional mounting schemes of an automotive engine-gearbox system when excited by oscillating torques. In particular, the issue of torque roll axis decoupling is analyzed in significant detail since it is poorly understood. New dynamic decoupling axioms are presented an d compared with the conventional elastic axis mounting and focalization methods. A linear time-invariant system assumption is made in addition to a proportionally damped system. Only rigid-body modes of the powertrain are considered and the chassis elements are assumed to be rigid. Several simplified physical systems are considered and new closed-form solutions for symmetric and asymmetric engine-mounting systems are developed. These clearly explain the design concepts for the 4-point mounting scheme. Our analytical solutions match with the existing design formulations that are only applicable to symmetric geometries. Spectra for all six rigid-body motions are predicted using the alternate decoupling methods and the closed-form solutions are verified. Also, our method is validated by comparing modal solutions with prior experimental and analytical studies. Parametric design studies are carried out to illustrate the methodology. Chief contributions of this research include the development of new or refined analytical models and closed-form solutions along with improved design strategies for the torque roll axis decoupling.
An Apparatus for Pressure Injection of Solutions into Trees
Thomas W. Jones; Garold F. Gregory; Garold F. Gregory
1971-01-01
The construction and use of an apparatus for injecting solutions under pressure into trees is described. A unique and important feature of the apparatus is that it permits injection of solutions into the outermost sapwood. It has been used to inject dye solutions and solubilized benomyl into elm, oak, and maple.
Lubrication of rigid ellipsida solids
NASA Technical Reports Server (NTRS)
Hamrock, B. J.; Dowson, D.
1982-01-01
The influence of geometry on the isothermal hydrodynamic film separating two rigid solids was investigated. The minimum film thickness is derived for fully flooded conjunctions by using the Reynolds boundary conditions. It was found that the minimum film thickness had the same speed, viscosity, and load dependence as Kapitza' classical solution. However, the incorporation of Reynolds boundary conditions resulted in an additional geometry effect. Solutions using the parabolic film approximation are compared by using the exact expression for the film in the analysis. Contour plots are known that indicate in detail the pressure developed between the solids.
An analytical solution for the squeeze film between a nondeformable sphere and groove
NASA Technical Reports Server (NTRS)
Allen, C. W.; Wilson, M. P.
1972-01-01
An analysis is presented to compute the film thickness, pressure and load relations between a rigid ball and rigid groove in normal approach when lubricated by a fluid with an exponential pressure-viscosity relationship. The geometry of the ball-groove system is reduced to the equivalent system of a paraboloid approaching a flat plate. Exact and approximate solutions are presented for the load and pressure relations. There is found to be a limiting load for a given geometry and lubricant regardless of the rate of approach.
Bohr Hamiltonian for γ = 30° with Davidson potential
NASA Astrophysics Data System (ADS)
Yigitoglu, Ibrahim; Gokbulut, Melek
2018-03-01
A γ-rigid solution of the Bohr Hamiltonian for γ = 30° is constructed with the Davidson potential in the β part. This solution is going to be called Z(4)-D. The energy eigenvalues and wave functions are obtained by using the analytic method developed by Nikiforov and Uvarov. The calculated intraband and interband B(E2) transitions rates are presented and compared with the Z(4) model predictions. The staggering behavior in γ-bands is considered to search Z(4) -D candidate nuclei. A variational procedure is applied to demonstrate that the Z(4) model is a solution of the critical point at the shape phase transition from spherical to rigid triaxial rotor.
Kuzman, Tomislav; Kutija, Marija Barisić; Kordić, Rajko; Popović-Sui, Smiljka; Jandroković, Sonja; Skegro, Ivan; Pokupec, Rajko
2013-04-01
The aim of this study was to compare antimicrobial efficacy of rigid contact lens disinfecting solutions. We tested five commercially available solutions: Unique pH (Alcon Laboratories), Boston Advance (Polymer Technology Corp.), Nitilens Conditioner GP (Avizor), Total Care (AMO), Boston Simplus (Bausch&Lomb). Their efficacy to disinfect saline solution experimentally contaminated with American Type Culture Collection (ATCC): Staphylococcus aureus (ATCC 25923), Escherichia coli (ATCC 25922), Pseudomonas aeruginosa (ATCC 27853), Candida albicans (ATCC 90028) and Staphylococcus epidermidis (isolated from our laboratory) was tested. All tested solutions reduced concentrations of bacteria and fungi below 1000 CFU/mL (Colony forming unit; reduction by 3 log and 1 log, respectively) after the 8 hours period. Overall, all contact lens care solutions showed good disinfecting activity against tested bacteria and fungi, with more variation in their antifungal than in antibacterial efficacy. Results of our study might be valuable when selecting appropriate solutions for non-compliant contact lens wearers.
Graph rigidity, cyclic belief propagation, and point pattern matching.
McAuley, Julian J; Caetano, Tibério S; Barbosa, Marconi S
2008-11-01
A recent paper [1] proposed a provably optimal polynomial time method for performing near-isometric point pattern matching by means of exact probabilistic inference in a chordal graphical model. Its fundamental result is that the chordal graph in question is shown to be globally rigid, implying that exact inference provides the same matching solution as exact inference in a complete graphical model. This implies that the algorithm is optimal when there is no noise in the point patterns. In this paper, we present a new graph that is also globally rigid but has an advantage over the graph proposed in [1]: Its maximal clique size is smaller, rendering inference significantly more efficient. However, this graph is not chordal, and thus, standard Junction Tree algorithms cannot be directly applied. Nevertheless, we show that loopy belief propagation in such a graph converges to the optimal solution. This allows us to retain the optimality guarantee in the noiseless case, while substantially reducing both memory requirements and processing time. Our experimental results show that the accuracy of the proposed solution is indistinguishable from that in [1] when there is noise in the point patterns.
VizieR Online Data Catalog: SMART97, rigid Earth rotation new solution (Bretagnon+ 1998)
NASA Astrophysics Data System (ADS)
Bretagnon, P.; Francou, G.; Rocher, P.; Simon, J. L.
1998-03-01
The Earth rotation solution SMART97 (Solution du Mouvement de l'Axe de Rotation de la Terre) is an analytical solution of the Earth rotation in the rigid case. It gives the expressions of precession-nutation and rotation of the Earth for the 3 Euler angles ψ, ω, φ as well as for the quantities p, ɛ, χ, and the sidereal time. For the axis of figure (fig), these 7 quantities are given in the dynamical system (dyn) and in the kinematical system (kin). SMART97 also gives the variables ψ and ω, in the dynamical system, for the differences (axis of figure - axis of rotation) (rot) and (axis of figure - axis of the angular momentum) (ang). The accuracy of the solution is better than 2.2 microarcseconds for all these variables over 20000 days, between 1968 and 2023. A program EXAMPLE (Fortran 77) is provided which makes use of the subroutine SMART97 which substitutes the time in the series of the solutions SMART97. (18 data files).
Injectable bioadhesive hydrogels with innate antibacterial properties
NASA Astrophysics Data System (ADS)
Giano, Michael C.; Ibrahim, Zuhaib; Medina, Scott H.; Sarhane, Karim A.; Christensen, Joani M.; Yamada, Yuji; Brandacher, Gerald; Schneider, Joel P.
2014-06-01
Surgical site infections cause significant postoperative morbidity and increased healthcare costs. Bioadhesives used to fill surgical voids and support wound healing are typically devoid of antibacterial activity. Here we report novel syringe-injectable bioadhesive hydrogels with inherent antibacterial properties prepared from mixing polydextran aldehyde and branched polyethylenimine. These adhesives kill both Gram-negative and Gram-positive bacteria, while sparing human erythrocytes. An optimal composition of 2.5 wt% oxidized dextran and 6.9 wt% polyethylenimine sets within seconds forming a mechanically rigid (~\
Intramuscular temperature modulates glutamate-evoked masseter muscle pain intensity in humans.
Sato, Hitoshi; Castrillon, Eduardo E; Cairns, Brian E; Bendixen, Karina H; Wang, Kelun; Nakagawa, Taneaki; Wajima, Koichi; Svensson, Peter
2015-01-01
To determine whether glutamate-evoked jaw muscle pain is altered by the temperature of the solution injected. Sixteen healthy volunteers participated and received injections of hot (48°C), neutral (36°C), or cold (3°C) solutions (0.5 mL) of glutamate or isotonic saline into the masseter muscle. Pain intensity was assessed with an electronic visual analog scale (eVAS). Numeric rating scale (NRS) scores of unpleasantness and temperature perception, pain-drawing areas, and pressure pain thresholds (PPTs) were also measured. Participants filled out the McGill Pain Questionnaire (MPQ). Two-way or three-way repeated measures ANOVA were used for data analyses. Injection of hot glutamate and cold glutamate solutions significantly increased and decreased, respectively, the peak pain intensity compared with injection of neutral glutamate solution. The duration of glutamate-evoked pain was significantly longer when hot glutamate was injected than when cold glutamate was injected. No significant effect of temperature on pain intensity was observed when isotonic saline was injected. No effect of solution temperature was detected on unpleasantness, heat perception, cold perception, area of pain drawings, or PPTs. There was a significantly greater use of the "numb" term in the MPQ to describe the injection of cold solutions compared to the injection of both neutral and hot solutions. Glutamate-evoked jaw muscle pain was significantly altered by the temperature of the injection solution. Although temperature perception in the jaw muscle is poor, pain intensity is increased when the muscle tissue temperature is elevated.
Mitri, F G; Fellah, Z E A
2011-08-01
The present investigation examines the instantaneous force resulting from the interaction of an acoustical high-order Bessel vortex beam (HOBVB) with a rigid sphere. The rigid sphere case is important in fluid dynamics applications because it perfectly simulates the interaction of instantaneous sound waves in a reduced gravity environment with a levitated spherical liquid soft drop in air. Here, a closed-form solution for the instantaneous force involving the total pressure field as well as the Bessel beam parameters is obtained for the case of progressive, stationary and quasi-stationary waves. Instantaneous force examples for progressive waves are computed for both a fixed and a movable rigid sphere. The results show how the instantaneous force per unit cross-sectional surface and unit pressure varies versus the dimensionless frequency ka (k is the wave number in the fluid medium and a is the sphere's radius), the half-cone angle β and the order m of the HOBVB. It is demonstrated here that the instantaneous force is determined only for (m,n) = (0,1) (where n is the partial-wave number), and vanishes for m>0 because of symmetry. In addition, the instantaneous force and normalized amplitude velocity results are computed and compared with those of a rigid immovable (fixed) sphere. It is shown that they differ significantly for ka values below 5. The proposed analysis may be of interest in the analysis of instantaneous forces on spherical particles for particle manipulation, filtering, trapping and drug delivery. The presented solutions may also serve as a method for comparison to other solutions obtained by strictly numerical or asymptotic approaches. Copyright © 2011 Elsevier B.V. All rights reserved.
Gyre and gimble: a maximum-likelihood replacement for Patterson correlation refinement.
McCoy, Airlie J; Oeffner, Robert D; Millán, Claudia; Sammito, Massimo; Usón, Isabel; Read, Randy J
2018-04-01
Descriptions are given of the maximum-likelihood gyre method implemented in Phaser for optimizing the orientation and relative position of rigid-body fragments of a model after the orientation of the model has been identified, but before the model has been positioned in the unit cell, and also the related gimble method for the refinement of rigid-body fragments of the model after positioning. Gyre refinement helps to lower the root-mean-square atomic displacements between model and target molecular-replacement solutions for the test case of antibody Fab(26-10) and improves structure solution with ARCIMBOLDO_SHREDDER.
Boundary value problem for the solution of magnetic cutoff rigidities and some special applications
NASA Technical Reports Server (NTRS)
Edmonds, Larry
1987-01-01
Since a planet's magnetic field can sometimes provide a spacecraft with some protection against cosmic ray and solar flare particles, it is important to be able to quantify this protection. This is done by calculating cutoff rigidities. An alternate to the conventional method (particle trajectory tracing) is introduced, which is to treat the problem as a boundary value problem. In this approach trajectory tracing is only needed to supply boundary conditions. In some special cases, trajectory tracing is not needed at all because the problem can be solved analytically. A differential equation governing cutoff rigidities is derived for static magnetic fields. The presense of solid objects, which can block a trajectory and other force fields are not included. A few qualititative comments, on existence and uniqueness of solutions, are made which may be useful when deciding how the boundary conditions should be set up. Also included are topics on axially symmetric fields.
Nonlinear vibration of an axially loaded beam carrying rigid bodies
NASA Astrophysics Data System (ADS)
Barry, O.
2016-12-01
This paper investigates the nonlinear vibration due to mid-plane stretching of an axially loaded simply supported beam carrying multiple rigid masses. Explicit expressions and closed form solutions of both linear and nonlinear analysis of the present vibration problem are presented for the first time. The validity of the analytical model is demonstrated using finite element analysis and via comparison with the result in the literature. Parametric studies are conducted to examine how the nonlinear frequency and frequency response curve are affected by tension, rotational inertia, and number of intermediate rigid bodies.
Elastic properties of rigid fiber-reinforced composites
NASA Astrophysics Data System (ADS)
Chen, J.; Thorpe, M. F.; Davis, L. C.
1995-05-01
We study the elastic properties of rigid fiber-reinforced composites with perfect bonding between fibers and matrix, and also with sliding boundary conditions. In the dilute region, there exists an exact analytical solution. Around the rigidity threshold we find the elastic moduli and Poisson's ratio by decomposing the deformation into a compression mode and a rotation mode. For perfect bonding, both modes are important, whereas only the compression mode is operative for sliding boundary conditions. We employ the digital-image-based method and a finite element analysis to perform computer simulations which confirm our analytical predictions.
NASA Technical Reports Server (NTRS)
Smalley, Kurt B.; Tinker, Michael L.
2001-01-01
Dynamic characterization of a non-rigidized thin film inflatable antenna/solar concentrator structure with rigidized composite support struts is described in detail. A two-step finite element modeling approach in MSC/NASTRAN is utilized, consisting of: (1) a nonlinear static pressurization procedure used to obtain the updated stiffness matrix, and (2) a modal "restart" eigen solution that uses the modified stiffness matrix. Unique problems encountered in modeling of this large 5-m lightweight inflatable are identified, including considerable difficulty in obtaining convergence in the nonlinear pressurization solution. It was found that the extremely thin polyimide film material (.001 in or I mil) presents tremendous problems in obtaining a converged solution when internal pressure loading is applied. It was concluded that the ratios of film thickness to other geometric dimensions such as torus cross-sectional and ring diameter and lenticular diameter are the critical parameters for convergence of the pressurization procedure. Comparison of finite element predictions for frequency and mode shapes with experimental results indicated reasonable agreement considering the complexity of the structure, the film-to-air interaction, and the nonlinear material properties of the film. It was also concluded that analysis should be done using different finite element to codes to determine if a more robust and stable solution can be obtained.
Simulating Space Capsule Water Landing with Explicit Finite Element Method
NASA Technical Reports Server (NTRS)
Wang, John T.; Lyle, Karen H.
2007-01-01
A study of using an explicit nonlinear dynamic finite element code for simulating the water landing of a space capsule was performed. The finite element model contains Lagrangian shell elements for the space capsule and Eulerian solid elements for the water and air. An Arbitrary Lagrangian Eulerian (ALE) solver and a penalty coupling method were used for predicting the fluid and structure interaction forces. The space capsule was first assumed to be rigid, so the numerical results could be correlated with closed form solutions. The water and air meshes were continuously refined until the solution was converged. The converged maximum deceleration predicted is bounded by the classical von Karman and Wagner solutions and is considered to be an adequate solution. The refined water and air meshes were then used in the models for simulating the water landing of a capsule model that has a flexible bottom. For small pitch angle cases, the maximum deceleration from the flexible capsule model was found to be significantly greater than the maximum deceleration obtained from the corresponding rigid model. For large pitch angle cases, the difference between the maximum deceleration of the flexible model and that of its corresponding rigid model is smaller. Test data of Apollo space capsules with a flexible heat shield qualitatively support the findings presented in this paper.
NASA Astrophysics Data System (ADS)
Hishida, Toshiaki; Maremonti, Paolo
2017-11-01
Consider the Navier-Stokes flow in 3-dimensional exterior domains, where a rigid body is translating with prescribed translational velocity - h(t)u_∞ with constant vector u_∞ \\in R^3{\\setminus }{0}. Finn raised the question whether his steady solutions are attainable as limits for t→ ∞ of unsteady solutions starting from motionless state when h(t)=1 after some finite time and h(0)=0 (starting problem). This was affirmatively solved by Galdi et al. (Arch Ration Mech Anal 138:307-318, 1997) for small u_∞. We study some generalized situation in which unsteady solutions start from large motions being in L^3 . We then conclude that the steady solutions for small u_∞ are still attainable as limits of evolution of those fluid motions which are found as a sort of weak solutions. The opposite situation, in which h(t)=0 after some finite time and h(0)=1 (landing problem), is also discussed. In this latter case, the rest state is attainable no matter how large u_∞ is.
NASA Astrophysics Data System (ADS)
Hishida, Toshiaki; Maremonti, Paolo
2018-06-01
Consider the Navier-Stokes flow in 3-dimensional exterior domains, where a rigid body is translating with prescribed translational velocity - h(t)u_∞ with constant vector u_∞ \\in R^3{\\setminus }{0}. Finn raised the question whether his steady solutions are attainable as limits for t→ ∞ of unsteady solutions starting from motionless state when h(t)=1 after some finite time and h(0)=0 (starting problem). This was affirmatively solved by Galdi et al. (Arch Ration Mech Anal 138:307-318, 1997) for small u_∞. We study some generalized situation in which unsteady solutions start from large motions being in L^3. We then conclude that the steady solutions for small u_∞ are still attainable as limits of evolution of those fluid motions which are found as a sort of weak solutions. The opposite situation, in which h(t)=0 after some finite time and h(0)=1 (landing problem), is also discussed. In this latter case, the rest state is attainable no matter how large u_∞ is.
NASA Technical Reports Server (NTRS)
Litchford, Ron J.; Jeng, San-Mou
1992-01-01
The performance of a recently introduced statistical transport model for turbulent particle dispersion is studied here for rigid particles injected into a round turbulent jet. Both uniform and isosceles triangle pdfs are used. The statistical sensitivity to parcel pdf shape is demonstrated.
Detecting the Biopolymer Behavior of Graphene Nanoribbons in Aqueous Solution
NASA Astrophysics Data System (ADS)
Wijeratne, Sithara S.; Penev, Evgeni S.; Lu, Wei; Li, Jingqiang; Duque, Amanda L.; Yakobson, Boris I.; Tour, James M.; Kiang, Ching-Hwa
2016-08-01
Graphene nanoribbons (GNR), can be prepared in bulk quantities for large-area applications by reducing the product from the lengthwise oxidative unzipping of multiwalled carbon nanotubes (MWNT). Recently, the biomaterials application of GNR has been explored, for example, in the pore to be used for DNA sequencing. Therefore, understanding the polymer behavior of GNR in solution is essential in predicting GNR interaction with biomaterials. Here, we report experimental studies of the solution-based mechanical properties of GNR and their parent products, graphene oxide nanoribbons (GONR). We used atomic force microscopy (AFM) to study their mechanical properties in solution and showed that GNR and GONR have similar force-extension behavior as in biopolymers such as proteins and DNA. The rigidity increases with reducing chemical functionalities. The similarities in rigidity and tunability between nanoribbons and biomolecules might enable the design and fabrication of GNR-biomimetic interfaces.
Detecting the Biopolymer Behavior of Graphene Nanoribbons in Aqueous Solution
Wijeratne, Sithara S.; Penev, Evgeni S.; Lu, Wei; Li, Jingqiang; Duque, Amanda L.; Yakobson, Boris I.; Tour, James M.; Kiang, Ching-Hwa
2016-01-01
Graphene nanoribbons (GNR), can be prepared in bulk quantities for large-area applications by reducing the product from the lengthwise oxidative unzipping of multiwalled carbon nanotubes (MWNT). Recently, the biomaterials application of GNR has been explored, for example, in the pore to be used for DNA sequencing. Therefore, understanding the polymer behavior of GNR in solution is essential in predicting GNR interaction with biomaterials. Here, we report experimental studies of the solution-based mechanical properties of GNR and their parent products, graphene oxide nanoribbons (GONR). We used atomic force microscopy (AFM) to study their mechanical properties in solution and showed that GNR and GONR have similar force-extension behavior as in biopolymers such as proteins and DNA. The rigidity increases with reducing chemical functionalities. The similarities in rigidity and tunability between nanoribbons and biomolecules might enable the design and fabrication of GNR-biomimetic interfaces. PMID:27503635
NASA Technical Reports Server (NTRS)
Abdallah, Ayman A.; Barnett, Alan R.; Widrick, Timothy W.; Manella, Richard T.; Miller, Robert P.
1994-01-01
When using all MSC/NASTRAN eigensolution methods except Lanczos, the analyst can replace the coupled system rigid-body modes calculated within DMAP module READ with mass orthogonalized and normalized rigid-body modes generated from the system stiffness. This option is invoked by defining MSC/NASTRAN r-set degrees of freedom via the SUPORT bulk data card. The newly calculated modes are required if the rigid-body modes calculated by the eigensolver are not 'clean' due to numerical roundoffs in the solution. When performing transient structural dynamic load analysis, the numerical roundoffs can result in inaccurate rigid-body accelerations which affect steady-state responses. Unfortunately, when using the Lanczos method and defining r-set degrees of freedom, the rigid-body modes calculated within DMAP module REIGL are retained. To overcome this limitation and to allow MSC/NASTRAN to handle SUPORT degrees of freedom identically for all eigensolvers, a DMAP Alter has been written which replaces Lanczos-calculated rigid-body modes with stiffness-generated rigid-body modes. The newly generated rigid-body modes are normalized with respect to the system mass and orthogonalized using the Gram-Schmidt technique. This algorithm has been implemented as an enhancement to an existing coupled loads methodology.
Galiano, Marc; Rouprêt, Morgan; Beley, Sébastien; Gattegno, Bernard; Chartier-Kastler, Emmanuel; Richard, François
2007-04-01
To assess the value of visual sexual stimulation combined with intracavernous injections (ICI) in patients treated for severe erectile dysfunction. All patients with severe erectile dysfunction were prospectively included in this study between 2005 and 2006. The outpatient protocol consisted of comparing the efficacy of alprostadil ICI alone on D0 and ICI combined with erotic stimulation on D8. End-points were: time to onset and rigidity of erection. A subjective score (1 to 5) was used to quantify erection. Forty patients with a mean age of 64.5 years (range: 52-70 years) were included in the study. All patients had an IIEF5 score less than 15. Erectile dysfunction was secondary to urological surgery in 35% of cases. The mean time to onset of erection was 10 min 18 s (range: 2-20 min) on D0 and 10 min 50 s (range: 2-20 min) on D8. No significant difference for rigidity and quality of erection was observed between D0 and D8 and erections were scored as 5 in 30 cases (75%), 4 in 8 cases (20%) and 3 in 2 cases (5%) at each visit. Visual sexual stimulation has not been demonstrated to be truly effective in the hospital setting in combination with intracavernous injections. In order to increase the patient satisfaction rate, the urologist must above all educate the patient in the intracavernous injection technique in an appropriate environment.
Displacement field for an edge dislocation in a layered half-space
Savage, J.C.
1998-01-01
The displacement field for an edge dislocation in an Earth model consisting of a layer welded to a half-space of different material is found in the form of a Fourier integral following the method given by Weeks et al. [1968]. There are four elementary solutions to be considered: the dislocation is either in the half-space or the layer and the Burgers vector is either parallel or perpendicular to the layer. A general two-dimensional solution for a dip-slip faulting or dike injection (arbitrary dip) can be constructed from a superposition of these elementary solutions. Surface deformations have been calculated for an edge dislocation located at the interface with Burgers vector inclined 0??, 30??, 60??, and 90?? to the interface for the case where the rigidity of the layer is half of that of the half-space and the Poisson ratios are the same. Those displacement fields have been compared to the displacement fields generated by similarly situated edge dislocations in a uniform half-space. The surface displacement field produced by the edge dislocation in the layered half-space is very similar to that produced by an edge dislocation at a different depth in a uniform half-space. In general, a low-modulus (high-modulus) layer causes the half-space equivalent dislocation to appear shallower (deeper) than the actual dislocation in the layered half-space.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Altabet, Y. Elia; Debenedetti, Pablo G., E-mail: pdebene@princeton.edu
2014-11-14
Liquid water confined between hydrophobic objects of sufficient size becomes metastable with respect to its vapor at separations smaller than a critical drying distance. Macroscopic thermodynamic arguments predicting this distance have been restricted to the limit of perfectly rigid confining materials. However, no material is perfectly rigid and it is of interest to account for this fact in the thermodynamic analysis. We present a theory that combines the current macroscopic theory with the thermodynamics of elasticity to derive an expression for the critical drying distance for liquids confined between flexible materials. The resulting expression is the sum of the well-knownmore » drying distance for perfectly rigid confining materials and a new term that accounts for flexibility. Thermodynamic arguments show that this new term is necessarily positive, meaning that flexibility increases the critical drying distance. To study the expected magnitude and scaling behavior of the flexible term, we consider the specific case of water and present an example of drying between thin square elastic plates that are simply supported along two opposite edges and free at the remaining two. We find that the flexible term can be the same order of magnitude or greater than the rigid solution for materials of biological interest at ambient conditions. In addition, we find that when the rigid solution scales with the characteristic size of the immersed objects, the flexible term is independent of size and vice versa. Thus, the scaling behavior of the overall drying distance will depend on the relative weights of the rigid and flexible contributions.« less
Yamane, Ayaka; Higuchi, Hitoshi; Tomoyasu, Yumiko; Ishii-Maruhama, Minako; Maeda, Shigeru; Miyawaki, Takuya
2015-04-01
Recently, attention has been paid to dexmedetomidine, a selective α-2 adrenoceptor agonist, as a possible additive for local anesthesia. However, the effect of locally injected dexmedetomidine on the anesthetic action in humans has not fully been clarified. Thus, the purpose of the present study was to evaluate the effect of dexmedetomidine injected into the oral mucosa in combination with lidocaine on local anesthetic potency in humans. Twenty healthy volunteers were included in the present crossover double-blinded study. Lidocaine solution or lidocaine plus dexmedetomidine solution was submucosally injected into the alveolar mucosa in a crossover and double-blinded manner. The local anesthetic effect of the solutions was evaluated by measuring the current perception threshold (CPT) in the oral mucosa for 120 minutes after injection. Furthermore, the sedation level, blood pressure, and heart rate of the volunteers were evaluated. For statistical analysis, the Wilcoxon signed rank test and 2-way repeated measures analysis of variation were used. The CPT was increased with the 2 solutions and peaked 10 minutes after injection. CPT values 10 and 20 minutes after injection of lidocaine plus dexmedetomidine solution were considerably higher than those with lidocaine solution. The duration of an important increase in the CPT after injection with lidocaine plus dexmedetomidine solution was longer than that with lidocaine. Furthermore, the area under the time curve of CPT was considerably higher with lidocaine plus dexmedetomidine solution than with lidocaine solution. No volunteer showed a change in sedation level, blood pressure, or heart rate after injection with either test solution throughout the experiment. The present study showed that a combination of dexmedetomidine plus lidocaine considerably enhances the local anesthetic potency of lidocaine without any major influences on the cardiovascular system when locally injected into the oral mucosa. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Non-Rigid Structure Estimation in Trajectory Space from Monocular Vision
Wang, Yaming; Tong, Lingling; Jiang, Mingfeng; Zheng, Junbao
2015-01-01
In this paper, the problem of non-rigid structure estimation in trajectory space from monocular vision is investigated. Similar to the Point Trajectory Approach (PTA), based on characteristic points’ trajectories described by a predefined Discrete Cosine Transform (DCT) basis, the structure matrix was also calculated by using a factorization method. To further optimize the non-rigid structure estimation from monocular vision, the rank minimization problem about structure matrix is proposed to implement the non-rigid structure estimation by introducing the basic low-rank condition. Moreover, the Accelerated Proximal Gradient (APG) algorithm is proposed to solve the rank minimization problem, and the initial structure matrix calculated by the PTA method is optimized. The APG algorithm can converge to efficient solutions quickly and lessen the reconstruction error obviously. The reconstruction results of real image sequences indicate that the proposed approach runs reliably, and effectively improves the accuracy of non-rigid structure estimation from monocular vision. PMID:26473863
The effects of injected solution temperature on intravenous regional anaesthesia.
Paul, D L; Logan, M R; Wildsmith, J A
1988-05-01
Ten healthy volunteers received three standard Bier's blocks. Prilocaine 0.5%, 40 ml was injected at a solution temperature of 0 degrees C, 22 degrees C or 37 degrees C. Recordings were made of sensory block, motor block, intravenous pressure, limb temperature and pain on injection. There were no differences between the three treatments in the rate of development or in the quality of block but there was a significant difference in the comfort of injection. Cold solutions caused most, and warm solutions least discomfort.
Saline as the Sole Contrast Agent for Successful MRI-guided Epidural Injections
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deli, Martin, E-mail: martin.deli@web.de; Fritz, Jan, E-mail: jfritz9@jhmi.edu; Mateiescu, Serban, E-mail: mateiescu@microtherapy.de
Purpose. To assess the performance of sterile saline solution as the sole contrast agent for percutaneous magnetic resonance imaging (MRI)-guided epidural injections at 1.5 T. Methods. A retrospective analysis of two different techniques of MRI-guided epidural injections was performed with either gadolinium-enhanced saline solution or sterile saline solution for documentation of the epidural location of the needle tip. T1-weighted spoiled gradient echo (FLASH) images or T2-weighted single-shot turbo spin echo (HASTE) images visualized the test injectants. Methods were compared by technical success rate, image quality, table time, and rate of complications. Results. 105 MRI-guided epidural injections (12 of 105 withmore » gadolinium-enhanced saline solution and 93 of 105 with sterile saline solution) were performed successfully and without complications. Visualization of sterile saline solution and gadolinium-enhanced saline solution was sufficient, good, or excellent in all 105 interventions. For either test injectant, quantitative image analysis demonstrated comparable high contrast-to-noise ratios of test injectants to adjacent body substances with reliable statistical significance levels (p < 0.001). The mean table time was 22 {+-} 9 min in the gadolinium-enhanced saline solution group and 22 {+-} 8 min in the saline solution group (p = 0.75). Conclusion. Sterile saline is suitable as the sole contrast agent for successful and safe percutaneous MRI-guided epidural drug delivery at 1.5 T.« less
Vote, D J; Platter, W J; Tatum, J D; Schmidt, G R; Belk, K E; Smith, G C; Speer, N C
2000-04-01
Beef strip loins (46 U.S. Choice loins and 49 U.S. Select loins) were used to evaluate the potential for enhancing beef tenderness, juiciness, and flavor by injecting fresh cuts with solutions containing sodium tripolyphosphate, sodium lactate, and sodium chloride. One half of each loin served as an untreated control, and the other half was injected with either distilled water (110% of raw weight) or a solution containing phosphate/lactate/chloride solution (107.5, 110, 112.5, or 115% of raw weight). All phosphate/lactate/chloride solutions were formulated to produce injected product concentrations of .25% sodium tripolyphosphate, .5% sodium chloride, and 2.5% sodium lactate. Ten additional U.S. Select loins were injected to 110% of raw weight with a phosphate-only solution (final product concentration of .25% sodium tripolyphosphate) for comparison with Select loins injected to 110% with phosphate/lactate/chloride and with distilled water. Steaks from each control and treated loin section were cooked to two final internal temperatures (66 degrees C and 77 degrees C) for sensory panel evaluation and shear force measurement. Injection of subprimal cuts with phosphate/lactate/chloride solutions improved tenderness (P < .05), juiciness (P < .05), and cooked beef flavor (P < .10) of strip loin steaks and was especially effective for maintaining tenderness and juiciness of steaks cooked to the higher final internal temperature. Injection of Select loins with a solution containing only sodium tripolyphosphate was not effective for improving beef tenderness or juiciness and tended to impart off-flavors characterized by sensory panelists as soapy and sour. Injection of fresh cuts with phosphate/lactate/chloride solutions could assist the beef industry's efforts to improve product quality and consistency.
Analytic Theory and Control of the Motion of Spinning Rigid Bodies
NASA Technical Reports Server (NTRS)
Tsiotras, Panagiotis
1993-01-01
Numerical simulations are often resorted to, in order to understand the attitude response and control characteristics of a rigid body. However, this approach in performing sensitivity and/or error analyses may be prohibitively expensive and time consuming, especially when a large number of problem parameters are involved. Thus, there is an important role for analytical models in obtaining an understanding of the complex dynamical behavior. In this dissertation, new analytic solutions are derived for the complete attitude motion of spinning rigid bodies, under minimal assumptions. Hence, we obtain the most general solutions reported in the literature so far. Specifically, large external torques and large asymmetries are included in the problem statement. Moreover, problems involving large angular excursions are treated in detail. A new tractable formulation of the kinematics is introduced which proves to be extremely helpful in the search for analytic solutions of the attitude history of such kinds of problems. The main utility of the new formulation becomes apparent however, when searching for feedback control laws for stabilization and/or reorientation of spinning spacecraft. This is an inherently nonlinear problem, where standard linear control techniques fail. We derive a class of control laws for spin axis stabilization of symmetric spacecraft using only two pairs of gas jet actuators. Practically, this could correspond to a spacecraft operating in failure mode, for example. Theoretically, it is also an important control problem which, because of its difficulty, has received little, if any, attention in the literature. The proposed control laws are especially simple and elegant. A feedback control law that achieves arbitrary reorientation of the spacecraft is also derived, using ideas from invariant manifold theory. The significance of this research is twofold. First, it provides a deeper understanding of the fundamental behavior of rigid bodies subject to body-fixed torques. Assessment of the analytic solutions reveals that they are very accurate; for symmetric bodies the solutions of Euler's equations of motion are, in fact, exact. Second, the results of this research have a fundamental impact on practical scientific and mechanical applications in terms of the analysis and control of all finite-sized rigid bodies ranging from nanomachines to very large bodies, both man made and natural. After all, Euler's equations of motion apply to all physical bodies, barring only the extreme limits of quantum mechanics and relativity.
Modeling the Influence of Injection Modes on the Evolution of Solution Sprays in a Plasma Jet
NASA Astrophysics Data System (ADS)
Shan, Y.; Coyle, T. W.; Mostaghimi, J.
2010-01-01
Solution precursor plasma spraying (SPPS) is a novel technology with great potential for depositing finely structured ceramic coatings with nano- and sub-micrometric features. The solution is injected into the plasma jet either as a liquid stream or gas atomized droplets. Solution droplets or the stream interact with the plasma jet and break up into fine droplets. The solvent vaporizes very fast as the droplets travel downstream. Solid particles are finally formed, and the particle are heated up and accelerated to the substrate to generate the coating. The deposition process and the properties of coatings obtained are extremely sensitive to the process parameters, such as torch operating conditions, injection modes, injection parameters, and substrate temperatures. This article numerically investigates the effect of injection modes, a liquid stream injection and a gas-blast injection, on the size distribution of injected droplets. The particle/droplet size, temperature, and position distributions on the substrate are predicted for different injection modes.
Consensus statement of the consortium for LESS cholecystectomy.
Ross, Sharona; Rosemurgy, Alexander; Albrink, Michael; Choung, Edward; Dapri, Giovanni; Gallagher, Scott; Hernandez, Jonathan; Horgan, Santiago; Kelley, William; Kia, Michael; Marks, Jeffrey; Martinez, Jose; Mintz, Yoav; Oleynikov, Dmitry; Pryor, Aurora; Rattner, David; Rivas, Homero; Roberts, Kurt; Rubach, Eugene; Schwaitzberg, Steven; Swanstrom, Lee; Sweeney, John; Wilson, Erik; Zemon, Harry; Zundel, Natan
2012-10-01
Many surgeons attempting Laparo-Endoscopic Single Site (LESS) cholecystectomy have found the operation difficult, which is inconsistent with our experience. This article is an attempt to promote a standardized approach that we feel surgeons with laparoscopic skills can perform safely and efficiently. This is a four-trocar approach consistent with the four incisions utilized in conventional laparoscopic cholecystectomy. After administration of general anesthesia, marcaine is injected at the umbilicus and a 12-mm vertical incision is made through the already existing anatomical scar of the umbilicus. A single four-trocar port is inserted. A 5-mm deflectable-tip laparoscope is placed through the trocar at the 8 o'clock position, a bariatric length rigid grasper is inserted through the trocar at the 4 o'clock position (to grasp the fundus), and a rigid bent grasper is placed through the 10-mm port (to grasp the infundibulum). This arrangement of the instruments promotes minimal internal and external instrument clashing with simultaneous optimization of the operative view. This orientation allows retraction of the gallbladder in a cephalad and lateral direction, development of a window between the gallbladder and the liver which promotes the "critical view" of the cystic duct and artery, and provides triangulation with excellent visualization of the operative field. The operation is concluded with diaphragmatic irrigation of marcaine solution to minimize postoperative pain. Standardization of LESS cholecystectomy will speed adoption, reduce intraoperative complications, and improve the efficiency and safety of the approach.
NASA Astrophysics Data System (ADS)
Nashida, Norihiro; Suzuki, Hiroaki
A microfluidic system with injecting and flushing functions was developed. In the system, hydrophilic flow channels have a dry-film photoresist layer which facilitates the introduction of solutions from four injection ports. The injection and flushing of solutions are controlled by valves operated by electrowetting. The valves consist of gold working electrodes in the flow channels or a through-hole in the glass substrate. Solutions can be sequentially introduced through the injection ports into a reaction chamber and flushed through a valve in the through-hole. Necessary immunoassay steps can be conducted on the chip, and a target antibody can be detected electrochemically.
Lansdowne, Jennifer L; Kerr, Carolyn L; Bouré, Ludovic P; Pearce, Simon G
2005-08-01
To determine the relationship between epidural cranial migration and injectate volume of an isotonic solution containing dye in laterally recumbent foal cadavers and evaluate the cranial migration and dermatome analgesia of an epidural dye solution during conditions of laparoscopy in foals. 19 foal cadavers and 8 pony foals. Foal cadavers received an epidural injection of dye solution (0.05, 0.1, 0.15, or 0.2 mL/kg) containing 1.2 mg of new methylene blue (NMB)/mL of saline (0.9% NaCl) solution. Length of the dye column and number of intervertebral spaces cranial and caudal to the injection site were measured. Anesthetized foals received an epidural injection of dye solution (0.2 mL/kg) containing saline solution or 2% mepivacaine. Foals were placed in a 100 head-down position, and pneumoperitoneum was induced. Dermatome analgesia was determined by use of a described electrical stimulus technique. Foals were euthanatized, and length of the dye column was measured. Epidural cranial migration of dye solution in foal cadavers increased with increasing volume injected. No significant difference was found in epidural cranial migration of a dye solution (0.2 mL/kg) between anesthetized foals undergoing conditions of laparoscopy and foal cadavers in lateral recumbency. Further craniad migration of the dye column occurred than indicated by dermatome analgesia. Epidural cranial migration increases with volume of injectate. On the basis of dermatome analgesia, an epidural injection of 2% mepivacaine (0.2 mL/kg) alone provides analgesia up to at least the caudal thoracic dermatome and could permit caudal laparoscopic surgical procedures in foals.
Holcombe, Jr., Cressie E.; Swain, Ronald L.; Banker, John G.; Edwards, Charlene C.
1978-01-01
Adhesive plaster compositions are provided by treating particles of Y.sub.2 O.sub.3, Eu.sub.2 O.sub.3, Gd.sub.2 O.sub.3 or Nd.sub.2 O.sub.3 with dilute acid solutions. The resulting compositions have been found to spontaneously harden into rigid reticulated masses resembling plaster of Paris. Upon heating, the hardened material is decomposed into the oxide, yet retains the reticulated rigid structure.
Contamination of injectable solutions with 2-mercaptobenzothiazole leached from rubber closures.
Reepmeyer, J C; Juhl, Y H
1983-11-01
An impurity, discovered in a sample of digoxin injectable solution commercially packaged in a syringe for single-dose delivery, was found to originate from the rubber closure of the syringe and was identified as 2-mercaptobenzothiazole, a common accelerator for rubber vulcanization. Several similarly packaged injectable solutions of a variety of drugs from various manufacturers were examined and over half contained 2-mercaptobenzothiazole. The compound was identified by UV spectrophotometry (including a pH-dependent shift in its absorbance maximum), by mass spectrometry, and by comparison with standard 2-mercaptobenzothiazole using silica gel and reverse-phase high-performance liquid chromatography (HPLC). The presence of this impurity in injectable solutions may have implications with regard to toxicity and may interfere with the assay of digoxin injectable solution by HPLC.
Planar dynamics of a uniform beam with rigid bodies affixed to the ends
NASA Technical Reports Server (NTRS)
Storch, J.; Gates, S.
1983-01-01
The planar dynamics of a uniform elastic beam subject to a variety of geometric and natural boundary conditions and external excitations were analyzed. The beams are inextensible and capable of small transverse bending deformations only. Classical beam vibration eigenvalue problems for a cantilever with tip mass, a cantilever with tip body and an unconstrained beam with rigid bodies at each are examined. The characteristic equations, eigenfunctions and orthogonality relations for each are derived. The forced vibration of a cantilever with tip body subject to base acceleration is analyzed. The exact solution of the governing nonhomogeneous partial differential equation with time dependent boundary conditions is presented and compared with a Rayleigh-Ritz approximate solution. The arbitrary planar motion of an elastic beam with rigid bodies at the ends is addressed. Equations of motion are derived for two modal expansions of the beam deflection. The motion equations are cast in a first order form suitable for numerical integration. Selected FORTRAN programs are provided.
An experimental study of wall-injected flows in a rectangular cylinder
NASA Astrophysics Data System (ADS)
Perrotta, A.; Romano, G. P.; Favini, B.
2018-01-01
An experimental investigation of the flow inside a rectangular cylinder with air injected continuously along the wall is performed. This kind of flow is a two-dimensional approximation of what happens inside a solid rocket motor, where the lateral grain burns expelling exhaust gas or in processes with air filtration or devices to attain uniform flows. We propose a brief derivation of some analytical solutions and a comparison between these solutions and experimental data, which are obtained using the particle image velocimetry technique, to provide a global reconstruction of the flowfield. The flow, which enters orthogonal to the injecting wall, turns suddenly its direction being pushed towards the exit of the chamber. Under the incompressible and inviscid flow hypothesis, two analytical solutions are reported and compared. The first one, known as Hart-McClure solution, is irrotational and the injection velocity is non-perpendicular to the injecting wall. The other one, due to Taylor and Culick, has non-zero vorticity and constant, vertical injection velocity. The comparison with laminar solutions is useful to assess whether transition to turbulence is reached and how the disturbance thrown in by the porous injection influences and modifies those solutions.
NASA Technical Reports Server (NTRS)
Shih, K. G.
1986-01-01
The existence of concave solutions of Berman's equation which describes the laminar flow in channels with injection through porous walls is established. It was found that the (unique) concave solutions exist for all injection Reynolds number R < 0.
Ternary Phase Diagrams of PBZT/Zytel 330/MSA and PBZT/Lubrizol/MSA solutions
1990-01-01
8217]bisthiazole-2,6-diyl)- 1,4-phenylene (PBZT). This sytem represents a new class of rigid-rod molecular composite system that is different from all the rigid-rod...per square centimeter, I. In Equations form, this can be summarized by, -dI = a’ c Idb (15) log1O(I/Io)= logT = - abc (16) A = abc (17) where a’ is a
Coherent distributions for the rigid rotator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grigorescu, Marius
2016-06-15
Coherent solutions of the classical Liouville equation for the rigid rotator are presented as positive phase-space distributions localized on the Lagrangian submanifolds of Hamilton-Jacobi theory. These solutions become Wigner-type quasiprobability distributions by a formal discretization of the left-invariant vector fields from their Fourier transform in angular momentum. The results are consistent with the usual quantization of the anisotropic rotator, but the expected value of the Hamiltonian contains a finite “zero point” energy term. It is shown that during the time when a quasiprobability distribution evolves according to the Liouville equation, the related quantum wave function should satisfy the time-dependent Schrödingermore » equation.« less
Crushed and Injected Buprenorphine Tablets: Characteristics of Princeps and Generic Solutions
Bouquié, Régis; Wainstein, Laura; Pilet, Paul; Mussini, Jean-Marie; Deslandes, Guillaume; Clouet, Johann; Dailly, Eric; Jolliet, Pascale; Victorri-Vigneau, Caroline
2014-01-01
Self-injection of high-dose buprenorphine is responsible for well-described complications. In 2011, we have been alerted by unusual but serious cutaneous complication among injection buprenorphine users. A prospective data collection identified 30 cases of necrotic cutaneous lesions after injection of filtered buprenorphine solution, among which 25 cases occurred following injection of buprenorphine generics. The main goal of our study was to put forward particularities that could explain the cutaneous complications, by qualitatively and quantitatively confronting particles present in Subutex and generics solutions. We used the same protocol that injected-buprenorphine users: generic or subutex tablets were crushed in sterile water and filtered through 2 filters commonly used (cotton-pad and sterifilt). Solutions were analyzed by laser granulometry, flow cytometry and scanning electron microscopy. We have highlighted the wide variation of the quantity and the size of the particles present in solution between the two drugs after cotton-pad filtration. The proportion of particles <10 µm is systematically higher in the generic solutions than with Subutex. All of the insoluble particles found in generic solutions contain silica, whereas non- organic element was to be identified in the insoluble particles of Subutex. One skin biopsy obtained from one patient who developed a necrotic lesion after intravenous injection of filtrated solution of buprenorphine generic, shows non-organic elements. Identification of particles in situ enables us to confirm the presence of silica in the biopsy. Actually the monitoring of patient receiving generic of buprenorphine must be strengthened. PMID:25474108
The effect of injection of high K+ solution into scala media.
Fukazawa, T; Ohmura, M; Yagi, N
1987-01-01
Thirty guinea pig ears were studied to investigate the effect of endolymphatic hydrops on the cochlea. High K+ solution was injected into the scala media, and cochlear microphonics (CM) and endocochlear potential (EP) were observed before, during and after the injection. The CM amplitude decreased rapidly after injection, ending in a depressed plateau value. By contrast, EP remained almost unchanged. By changing the composition of the solution it was suggested that the effect of the injection was mechanical one, rather than biochemical. In three ears, spontaneous recovery of CM was observed during a relatively long interval after the injection. The meaning of these findings for the hearing loss in Meniere's disease is discussed.
Detecting the Biopolymer Behavior of Graphene Nanoribbons in Aqueous Solution
NASA Astrophysics Data System (ADS)
Li, Jingqiang; Wijeratne, Sithara; Penev, Evgeni; Lu, Wei; Duque, Amanda; Yakobson, Boris; Tour, James; Kiang, Ching-Hwa; Boris I. Yakobson Group Team; James M. Tour Group Team; Ching-Hwa Kiang Group Team
Graphene nanoribbons (GNR), can be prepared in bulk quantities for large-area applications by reducing the product from the lengthwise oxidative unzipping of multiwalled carbon nanotubes (MWNT). Recently, the biomaterials application of GNR has been explored, for example, in the pore to be used for DNA sequencing. Therefore, understanding the polymer behavior of GNR in solution is essential in predicting GNR interaction with biomaterials. Here, we report experimental studies of the solutionbased mechanical properties of GNR and their parent products, graphene oxide nanoribbons (GONR). We used atomic force microscopy (AFM) to study their mechanical properties in solution and showed that GNR and GONR have similar force-extension behavior as in biopolymers such as proteins and DNA. The rigidity increases with reducing chemical functionalities. The similarities in rigidity and tunability between nanoribbons and biomolecules might enable the design and fabrication of GNR-biomimetic interfaces.
Foam rigidized inflatable structural assemblies
NASA Technical Reports Server (NTRS)
Tinker, Michael L. (Inventor); Schnell, Andrew R. (Inventor)
2010-01-01
An inflatable and rigidizable structure for use as a habitat or a load bearing structure is disclosed. The structure consists of an outer wall and an inner wall defining a containment member and a bladder. The bladder is pressurized to erect the structure from an initially collapsed state. The containment member is subsequently injected with rigidizable fluid through an arrangement of injection ports. Exhaust gases from the curing rigidizable fluid are vented through an arrangement of exhaust ports. The rate of erection can be controlled by frictional engagement with a container or by using a tether. A method for fabricating a tubular structure is disclosed.
Adhesive plasters. [Patent application; coatings for crucibles, control rods, etc
Holcombe, C.E. Jr.; Swain, R.L.; Banker, J.G.; Edwards, C.C.
1975-09-26
Adhesive plaster compositions are provided by treating particles of Y/sub 2/O/sub 3/, Eu/sub 2/O/sub 3/, Gd/sub 2/O/sub 3/, or Nd/sub 2/O/sub 3/ with dilute acid solutions. The resulting compositions were found to harden spontaneously into rigid reticulated masses resembling plaster of Paris. Upon heating, the hardened material is decomposed into the oxide, yet retains the reticulated rigid structure. 1 table.
NASA Astrophysics Data System (ADS)
Chanyshev, AI; Abdulin, IM
2018-03-01
Two problems are solved in the paper: on ultimate loads in the initial stage of indentation of an absolutely rigid smooth wedge into a layer of an initially anisotropic plastic medium and in the final stage when the tool penetrates through the layer. The problems are solved with Chanyshev’s constitutive relations of plasticity of the initially anisotropic medium based on use of the eigen elasticity tensors.
The structure of shock wave in a gas consisting of ideally elastic, rigid spherical molecules
NASA Technical Reports Server (NTRS)
Cheremisin, F. G.
1972-01-01
Principal approaches are examined to the theoretical study of the shock layer structure. The choice of a molecular model is discussed and three procedures are formulated. These include a numerical calculation method, solution of the kinetic relaxation equation, and solution of the Boltzmann equation.
Ficts and facts of epinephrine and norepinephrine stability in injectable solutions.
Hoellein, Ludwig; Holzgrabe, Ulrike
2012-09-15
Epinephrine (EPI) and norepinephrine (NE) play an important role in emergency medicine and acute treatment of hypotension and shocks in the intensive care unit. Injectable solutions can either be provided as proprietary medicinal products or as individually prepared dilutions. Due to the chemical structure of EPI and NE, the stability of the corresponding solutions is limited. Thus, most manufacturers of EPI and NE injectable solutions use sulfites and nitrogen for stabilization, Nevertheless, storage conditions such as temperature and light have to be considered, but are often neglected in the daily hospital routine. In addition, hospital pharmacies prepare EPI and NE solutions and dilute commercially available solutions for individual therapy, especially on ICUs. Since the influence of dilution and the presence of excipients and other preservatives are not systematically explored, we collected published data and investigations on stability on the potency of EPI and NE injectable solutions in order to deduce storage recommendations for diluted EPI and NE solutions of different concentration. Copyright © 2012 Elsevier B.V. All rights reserved.
Characterization of polymeric solutions as injectable vehicles for hydroxyapatite microspheres.
Oliveira, Serafim M; Almeida, Isabel F; Costa, Paulo C; Barrias, Cristina C; Ferreira, M Rosa Pena; Bahia, M Fernanda; Barbosa, Mário A
2010-06-01
A polymeric solution and a reinforcement phase can work as an injectable material to fill up bone defects. However, the properties of the solution should be suitable to enable the transport of that extra phase. Additionally, the use of biocompatible materials is a requirement for tissue regeneration. Thus, we intended to optimize a biocompatible polymeric solution able to carry hydroxyapatite microspheres into bone defects using an orthopedic injectable device. To achieve that goal, polymers usually regarded as biocompatible were selected, namely sodium carboxymethylcellulose, hydroxypropylmethylcellulose, and Na-alginate (ALG). The rheological properties of the polymeric solutions at different concentrations were assessed by viscosimetry before and after moist heat sterilization. In order to correlate rheological properties with injectability, solutions were tested using an orthopedic device applied for minimal invasive surgeries. Among the three polymers, ALG solutions presented the most suitable properties for our goal and a non-sterile ALG 6% solution was successfully used to perform preliminary injection tests of hydroxyapatite microspheres. Sterile ALG 7.25% solution was found to closely match non-sterile ALG 6% properties and it was selected as the optimal vehicle. Finally, sterile ALG 7.25% physical stability was studied at different temperatures over a 3-month period. It was observed that its rheological properties presented minor changes when stored at 25 degrees C or at 4 degrees C.
Mitani, Kurie; Narimatsu, Shizuo; Izushi, Fumio; Kataoka, Hiroyuki
2003-07-14
A simple and rapid method was developed for analyzing contamination of endocrine disruptors in liquid medicines and intravenous injection solutions. Endocrine disrupting compounds such as bisphenol A (BPA), alkylphenols and phthalates were quantitated by on-line in-tube solid-phase microextraction coupled with high performance liquid chromatography (in-tube SPME/HPLC) with UV detection. The liquid medicines and intravenous injection solutions could be used directly without any pretreatment, and the BPA, alkylphenols and phthalates in these solutions were automatically analyzed. The limits of quantification for these compounds were 1-10 ng/ml. Recoveries of these compounds spiked to the intravenous injection solutions was over 80%, except for some phthalates. Di-n-butyl phthalate (DBP) was detected at a concentration of 7-60 ng/ml in most intravenous injection solutions in plastic containers, but it was not detected in solutions in glass bottles. Diethyl phthalate, di-n-propyl phthalate, DBP and di-2-ethylhexyl phthalate (DEHP) were also detected in syrup, lotion and eye drops in plastic containers. On the other hand, BPA and alkylphenols were not detected at all in these solutions. DEHP contamination from an administration set increased when total vitamin formulation was added to the infusion solution. DEHP was easily leached from polyvinyl chloride tubing by polysorbate 80. The in-tube SPME/HPLC method is simple, rapid and automatic, and it provides a useful tool for the screening and determination of endocrine disruptor contamination in liquid medicines and intravenous injection solutions.
The short range anion-H interaction is the driving force for crystal formation of ions in water.
Alejandre, José; Chapela, Gustavo A; Bresme, Fernando; Hansen, Jean-Pierre
2009-05-07
The crystal formation of NaCl in water is studied by extensive molecular dynamics simulations. Ionic solutions at room temperature and various concentrations are studied using the SPC/E and TIP4P/2005 water models and seven force fields of NaCl. Most force fields of pure NaCl fail to reproduce the experimental density of the crystal, and in solution some favor dissociation at saturated conditions, while others favor crystal formation at low concentration. A new force field of NaCl is proposed, which reproduces the experimental phase diagram in the solid, liquid, and vapor regions. This force field overestimates the solubility of NaCl in water at saturation conditions when used with standard Lorentz-Berthelot combining rules for the ion-water pair potentials. It is shown that precipitation of ions is driven by the short range interaction between Cl-H pairs, a term which is generally missing in the simulation of ionic solutions. The effects of intramolecular flexibility of water on the solubility of NaCl ions are analyzed and is found to be small compared to rigid models. A flexible water model, extending the rigid SPC/E, is proposed, which incorporates Lennard-Jones interactions centered on the hydrogen atoms. This force field gives liquid-vapor coexisting densities and surface tensions in better agreement with experimental data than the rigid SPC/E model. The Cl-H, Na-O, and Cl-O pair distribution functions of the rigid and flexible models agree well with experiment. The predicted concentration dependence of the electric conductivity is in fair agreement with available experimental data.
A numerical solution of Duffing's equations including the prediction of jump phenomena
NASA Technical Reports Server (NTRS)
Moyer, E. T., Jr.; Ghasghai-Abdi, E.
1987-01-01
Numerical methodology for the solution of Duffing's differential equation is presented. Algorithms for the prediction of multiple equilibrium solutions and jump phenomena are developed. In addition, a filtering algorithm for producing steady state solutions is presented. The problem of a rigidly clamped circular plate subjected to cosinusoidal pressure loading is solved using the developed algorithms (the plate is assumed to be in the geometrically nonlinear range). The results accurately predict regions of solution multiplicity and jump phenomena.
Gaussian step-pressure loading of rigid viscoplastic plates. Ph.D. Thesis
NASA Technical Reports Server (NTRS)
Hayduk, R. J.; Durling, B. J.
1978-01-01
The response of a thin, rigid viscoplastic plate subjected to a spatially axisymmetric Gaussian step pressure impulse loading was studied analytically. A Gaussian pressure distribution in excess of the collapse load was applied to the plate, held constant for a length of time, and then suddenly removed. The plate deforms with monotonically increasing deflections until the dynamic energy is completely dissipated in plastic work. The simply supported plate of uniform thickness obeys the von Mises yield criterion and a generalized constitutive equation for rigid viscoplastic materials. For the small deflection bending response of the plate, the governing system of equations is essentially nonlinear. Transverse shear stress is neglected in the yield condition and rotary inertia in the equations of dynamic equilibrium. A proportional loading technique, known to give excellent approximations of the exact solution for the uniform load case, was used to linearize the problem and to obtain the analytical solutions in the form of eigenvalue expansions. The effects of load concentration, of an order of magnitude change in the viscosity of the plate material, and of load duration were examined while holding the total impulse constant.
Garold F. Gregory; Thomas W. Jones
1973-01-01
A preliminary evaluation of the effectiveness of injecting methyl 2-benzimidazole carbamate hydrochloride solution into elms for prevention or cure of Dutch elm disease is reported. Symptom development was diminished or prevented in elms injected with fungicide before inoculation. Symptom development was arrested in all crown-inoculated diseased trees injected with the...
NASA Astrophysics Data System (ADS)
Zhang, Yan; Li, Wanshu; Zhang, Ting; Yang, Bo; Zheng, Qinghong; Xu, Jiwen; Wang, Hua; Wang, Lihui; Zhang, Xiaowen; Wei, Bin
2018-01-01
Low-cost and scalable manufacturing boosts organic electronic devices with all solution process. La2O3 powders and corresponding aqueous solutions are facilely synthesized. Atomic force microscopy and scanning electron microscopy measurements show that solution-processed La2O3 behaves superior film morphology. X-ray diffraction and X-ray photoelectron spectroscopy measurements verify crystal phase and typical La signals. In comparison with the most widely-used hole injection layers (HILs) of MoOx and poly(ethylene dioxythiophene):poly(styrene sulfonate) (PEDOT:PSS), enhanced luminous efficiency is observed in organic light-emitting diode (OLED) using solution-processed La2O3 HIL. Current-voltage, impedance-voltage and phase angle-voltage transition curves clarify that solution-processed La2O3 behaves nearly comparable hole injection capacity to MoOx and PEDOT:PSS, and favorably tailors carrier balance. Moreover, the hole injection mechanism of solution-processed La2O3 is proven to be predominantly controlled by Fowler-Nordheim tunneling process and the hole injection barrier height between ITO and NPB via La2O3 interlayer is estimated to be 0.098 eV. Our experiments provide a feasible application of La2O3 in organic electronic devices with solution process.
Chou, A; Hori, S; Takase, M
1985-01-01
Subconjunctival injection of 0.2 ml of the following solutions was carried out once a day for two weeks in the albino and pigmented rabbit: commercial 0.5% timolol or 1% befunolol ophthalmic solutions, both containing benzalkonium chloride, and also these drug solutions containing no preservative, ophthalmic base solutions containing benzalkonium chloride, physiological saline solution or phosphate buffer solution. One week after daily injections of the commercial drug solutions or base solutions with benzalkonium chloride, the electroretinogram (ERG) showed a marked reduction in the a- and b-wave amplitudes in the pigmented rabbit, but the ERG changes were slight in the albino rabbit. After two weeks of injections, histological studies of the pigmented rabbit eyes revealed retinal detachment, visual cell loss and atrophy of the retinal pigment epithelium and choroid; the changes in the albino rabbit eyes were minimal. Injections of the beta-blockers containing no benzalkonium resulted in no significant changes in the ERG or in the tissue structures of all rabbits. Injections of only physiological saline or phosphate buffer had no deleterious effects. Therefore, the ocular toxicity of the beta-blockers was thought to be minor and the toxic effects seen in this study were thought to be due to benzalkonium chloride, which possibly accumulates in the ocular pigments.
NASA Astrophysics Data System (ADS)
Ketcha, M. D.; De Silva, T.; Uneri, A.; Jacobson, M. W.; Goerres, J.; Kleinszig, G.; Vogt, S.; Wolinsky, J.-P.; Siewerdsen, J. H.
2017-06-01
A multi-stage image-based 3D-2D registration method is presented that maps annotations in a 3D image (e.g. point labels annotating individual vertebrae in preoperative CT) to an intraoperative radiograph in which the patient has undergone non-rigid anatomical deformation due to changes in patient positioning or due to the intervention itself. The proposed method (termed msLevelCheck) extends a previous rigid registration solution (LevelCheck) to provide an accurate mapping of vertebral labels in the presence of spinal deformation. The method employs a multi-stage series of rigid 3D-2D registrations performed on sets of automatically determined and increasingly localized sub-images, with the final stage achieving a rigid mapping for each label to yield a locally rigid yet globally deformable solution. The method was evaluated first in a phantom study in which a CT image of the spine was acquired followed by a series of 7 mobile radiographs with increasing degree of deformation applied. Second, the method was validated using a clinical data set of patients exhibiting strong spinal deformation during thoracolumbar spine surgery. Registration accuracy was assessed using projection distance error (PDE) and failure rate (PDE > 20 mm—i.e. label registered outside vertebra). The msLevelCheck method was able to register all vertebrae accurately for all cases of deformation in the phantom study, improving the maximum PDE of the rigid method from 22.4 mm to 3.9 mm. The clinical study demonstrated the feasibility of the approach in real patient data by accurately registering all vertebral labels in each case, eliminating all instances of failure encountered in the conventional rigid method. The multi-stage approach demonstrated accurate mapping of vertebral labels in the presence of strong spinal deformation. The msLevelCheck method maintains other advantageous aspects of the original LevelCheck method (e.g. compatibility with standard clinical workflow, large capture range, and robustness against mismatch in image content) and extends capability to cases exhibiting strong changes in spinal curvature.
Dynamics of elastic nonlinear rotating composite beams with embedded actuators
NASA Astrophysics Data System (ADS)
Ghorashi, Mehrdaad
2009-08-01
A comprehensive study of the nonlinear dynamics of composite beams is presented. The study consists of static and dynamic solutions with and without active elements. The static solution provides the initial conditions for the dynamic analysis. The dynamic problems considered include the analyses of clamped (hingeless) and articulated (hinged) accelerating rotating beams. Numerical solutions for the steady state and transient responses have been obtained. It is shown that the transient solution of the nonlinear formulation of accelerating rotating beam converges to the steady state solution obtained by the shooting method. The effect of perturbing the steady state solution has also been calculated and the results are shown to be compatible with those of the accelerating beam analysis. Next, the coupled flap-lag rigid body dynamics of a rotating articulated beam with hinge offset and subjected to aerodynamic forces is formulated. The solution to this rigid-body problem is then used, together with the finite difference method, in order to produce the nonlinear elasto-dynamic solution of an accelerating articulated beam. Next, the static and dynamic responses of nonlinear composite beams with embedded Anisotropic Piezo-composite Actuators (APA) are presented. The effect of activating actuators at various directions on the steady state force and moments generated in a rotating composite beam has been presented. With similar results for the transient response, this analysis can be used in controlling the response of adaptive rotating beams.
NASA Technical Reports Server (NTRS)
Longuski, James M.; Mcronald, Angus D.
1988-01-01
In previous work the problem of injecting the Galileo and Ulysses spacecraft from low earth orbit into their respective interplanetary trajectories has been discussed for the single stage (Centaur) vehicle. The central issue, in the event of spherically distributed injection errors, is what happens to the vehicle? The difficulties addressed in this paper involve the multi-stage problem since both Galileo and Ulysses will be utilizing the two-stage IUS system. Ulysses will also include a third stage: the PAM-S. The solution is expressed in terms of probabilities for total percentage of escape, orbit decay and reentry trajectories. Analytic solutions are found for Hill's Equations of Relative Motion (more recently called Clohessy-Wiltshire Equations) for multi-stage injections. These solutions are interpreted geometrically on the injection sphere. The analytic-geometric models compare well with numerical solutions, provide insight into the behavior of trajectories mapped on the injection sphere and simplify the numerical two-dimensional search for trajectory families.
[Development of injection containers for patient and medical staff].
Kawasaki, Yoichi; Sendo, Toshiaki
2015-01-01
Recently, there has been a transition from glass to plastic injection containers in Japan. In our previous study, we suggested that plastic containers had less impurity contamination than glass containers. However, the use of some plasticizers has been limited because of their endocrine disrupting effects. Therefore, contamination has been a concern due to chemicals in injection solution packed with plastic containers. Indeed, in our recent study, photoinitiators were detected in an injection solution coming from plastic containers. Photoinitiators mainly exist in ink. We therefore speculated that ink originating from a photoinitiator directly printing on plastic containers had migrated into the injection solutions. In a clinical setting, plastic containers are very tractable because they are lightweight and less breakable. On the other hand, from a safety view point, these containers may be hazardous because of permeation by steam, ambient air or photoinitiators. In the present symposium, we will discuss the risk of photoinitiators leaking into injection solution packed with plastic containers, and countermeasures to avoid this risk.
Ultimate Lateral Capacity of Rigid Pile in c- φ Soil
NASA Astrophysics Data System (ADS)
Zhang, Wei-min
2018-03-01
To date no analytical solution of the pile ultimate lateral capacity for the general c- φ soil has been obtained. In the present study, a new dimensionless embedded ratio was proposed and the analytical solutions of ultimate lateral capacity and rotation center of rigid pile in c- φ soils were obtained. The results showed that both the dimensionless ultimate lateral capacity and dimensionless rotation center were the univariate functions of the embedded ratio. Also, the ultimate lateral capacity in the c- φ soil was the combination of the ultimate lateral capacity ( f c ) in the clay, and the ultimate lateral capacity ( f φ ) in the sand. Therefore, the Broms chart for clay, solution for clay ( φ=0) put forward by Poulos and Davis, solution for sand ( c=0) obtained by Petrasovits and Awad, and Kondner's ultimate bending moment were all proven to be the special cases of the general solution in the present study. A comparison of the field and laboratory tests in 93 cases showed that the average ratios of the theoretical values to the experimental value ranged from 0.85 to 1.15. Also, the theoretical values displayed a good agreement with the test values.
Well completion process for formations with unconsolidated sands
Davies, David K.; Mondragon, III, Julius J.; Hara, Philip Scott
2003-04-29
A method for consolidating sand around a well, involving injecting hot water or steam through well casing perforations in to create a cement-like area around the perforation of sufficient rigidity to prevent sand from flowing into and obstructing the well. The cement area has several wormholes that provide fluid passageways between the well and the formation, while still inhibiting sand inflow.
Caldwell, Shane J.
2012-01-01
Aminoglycoside (6′) acetyltransferase-Ie/aminoglycoside (2″) phosphotransferase-Ia [AAC(6′)-Ie/APH(2″)-Ia] is one of the most problematic aminoglycoside resistance factors in clinical pathogens, conferring resistance to almost every aminoglycoside antibiotic available to modern medicine. Despite 3 decades of research, our understanding of the structure of this bifunctional enzyme remains limited. We used small-angle X-ray scattering (SAXS) to model the structure of this bifunctional enzyme in solution and to study the impact of substrate binding on the enzyme. It was observed that the enzyme adopts a rigid conformation in solution, where the N-terminal AAC domain is fixed to the C-terminal APH domain and not loosely tethered. The addition of acetyl-coenzyme A, coenzyme A, GDP, guanosine 5′-[β,γ-imido]triphosphate (GMPPNP), and combinations thereof to the protein resulted in only modest changes to the radius of gyration (RG) of the enzyme, which were not consistent with any large changes in enzyme structure upon binding. These results imply some selective advantage to the bifunctional enzyme beyond coexpression as a single polypeptide, likely linked to an improvement in enzymatic properties. We propose that the rigid structure contributes to improved electrostatic steering of aminoglycoside substrates toward the two active sites, which may provide such an advantage. PMID:22290965
Długosz, Maciej; Antosiewicz, Jan M
2014-01-14
We have investigated the rotational dynamics of hen egg white lysozyme in monodisperse aqueous solutions of concentrations up to 250 mg/mL, using a rigid-body Brownian dynamics method that accurately accounts for anisotropies of diffusing objects. We have examined the validity of the free diffusion concept in the analysis of computer simulations of volume-occupied molecular solutions. We have found that, when as the only intermolecular interaction, the excluded volume effect is considered, rotational diffusion of molecules adheres to the free diffusion model. Further, we present a method based on the exact (in the case of the free diffusion) analytic forms of autocorrelation functions of particular vectors rigidly attached to diffusing objects, which allows one to obtain from results of molecular simulations the three principal rotational diffusion coefficients characterizing rotational Brownian motion of an arbitrarily shaped rigid particle for an arbitrary concentration of crowders. We have applied this approach to trajectories resulting from Brownian dynamics simulations of hen egg white lysozyme solutions. We show that the apparent anisotropy of proteins' rotational motions increases with an increasing degree of crowding. Finally, we demonstrate that even if the hydrodynamic anisotropy of molecules is neglected and molecules are simulated using their average translational and rotational diffusion coefficients, excluded volume effects still lead to their anisotropic rotational dynamics.
NASA Astrophysics Data System (ADS)
Albaba, Adel; Lambert, Stéphane; Faug, Thierry
2018-05-01
The present paper investigates the mean impact force exerted by a granular mass flowing down an incline and impacting a rigid wall of semi-infinite height. First, this granular flow-wall interaction problem is modeled by numerical simulations based on the discrete element method (DEM). These DEM simulations allow computing the depth-averaged quantities—thickness, velocity, and density—of the incoming flow and the resulting mean force on the rigid wall. Second, that problem is described by a simple analytic solution based on a depth-averaged approach for a traveling compressible shock wave, whose volume is assumed to shrink into a singular surface, and which coexists with a dead zone. It is shown that the dead-zone dynamics and the mean force on the wall computed from DEM can be reproduced reasonably well by the analytic solution proposed over a wide range of slope angle of the incline. These results are obtained by feeding the analytic solution with the thickness, the depth-averaged velocity, and the density averaged over a certain distance along the incline rather than flow quantities taken at a singular section before the jump, thus showing that the assumption of a shock wave volume shrinking into a singular surface is questionable. The finite length of the traveling wave upstream of the grains piling against the wall must be considered. The sensitivity of the model prediction to that sampling length remains complicated, however, which highlights the need of further investigation about the properties and the internal structure of the propagating granular wave.
NASA Astrophysics Data System (ADS)
Henclik, Sławomir
2018-03-01
The influence of dynamic fluid-structure interaction (FSI) onto the course of water hammer (WH) can be significant in non-rigid pipeline systems. The essence of this effect is the dynamic transfer of liquid energy to the pipeline structure and back, which is important for elastic structures and can be negligible for rigid ones. In the paper a special model of such behavior is analyzed. A straight pipeline with a steady flow, fixed to the floor with several rigid supports is assumed. The transient is generated by a quickly closed valve installed at the end of the pipeline. FSI effects are assumed to be present mainly at the valve which is fixed with a spring dash-pot attachment. Analysis of WH runs, especially transient pressure changes, for various stiffness and damping parameters of the spring dash-pot valve attachment is presented in the paper. The solutions are found analytically and numerically. Numerical results have been computed with the use of an own computer program developed on the basis of the four equation model of WH-FSI and the specific boundary conditions formulated at the valve. Analytical solutions have been found with the separation of variables method for slightly simplified assumptions. Damping at the dash-pot is taken into account within the numerical study. The influence of valve attachment parameters onto the WH courses was discovered and it was found the transient amplitudes can be reduced. Such a system, elastically attached shut-off valve in a pipeline or other, equivalent design can be a real solution applicable in practice.
Localization in finite vibroimpact chains: Discrete breathers and multibreathers.
Grinberg, Itay; Gendelman, Oleg V
2016-09-01
We explore the dynamics of strongly localized periodic solutions (discrete solitons or discrete breathers) in a finite one-dimensional chain of oscillators. Localization patterns with both single and multiple localization sites (breathers and multibreathers) are considered. The model involves parabolic on-site potential with rigid constraints (the displacement domain of each particle is finite) and a linear nearest-neighbor coupling. When the particle approaches the constraint, it undergoes an inelastic impact according to Newton's impact model. The rigid nonideal impact constraints are the only source of nonlinearity and damping in the system. We demonstrate that this vibro-impact model allows derivation of exact analytic solutions for the breathers and multibreathers with an arbitrary set of localization sites, both in conservative and in forced-damped settings. Periodic boundary conditions are considered; exact solutions for other types of boundary conditions are also available. Local character of the nonlinearity permits explicit derivation of a monodromy matrix for the breather solutions. Consequently, the stability of the derived breather and multibreather solutions can be efficiently studied in the framework of simple methods of linear algebra, and with rather moderate computational efforts. One reveals that that the finiteness of the chain fragment and possible proximity of the localization sites strongly affect both the existence and the stability patterns of these localized solutions.
An analytical solution for modeling thermal energy transfer in a confined aquifer system
NASA Astrophysics Data System (ADS)
Shaw-Yang, Yang; Hund-der, Yeh
2008-12-01
A mathematical model is developed for simulating the thermal energy transfer in a confined aquifer with different geological properties in the underlying and overlying rocks. The solutions for temperature distributions in the aquifer, underlying rock, and overlying rock are derived by the Laplace transforms and their corresponding time-domain solutions are evaluated by the modified Crump method. Field data adopted from the literature are used as examples to demonstrate the applicability of the solutions in modeling the heat transfer in an aquifer thermal energy storage (ATES) system. The results show that the aquifer temperature increases with time, injection flow rate, and water temperature. However, the temperature decreases with increasing radial and vertical distances. The heat transfer in the rocks is slow and has an effect on the aquifer temperature only after a long period of injection time. The influence distance depends on the aquifer physical and thermal properties, injection flow rate, and injected water temperature. A larger value of thermal diffusivity or injection flow rate will result in a longer influence distance. The present solution can be used as a tool for designing the heat injection facilities for an ATES system.
NASA Astrophysics Data System (ADS)
Zhang, Xiaowen; Zheng, Qinghong; Tang, Zhenyu; Li, Wanshu; Zhang, Yan; Xu, Kai; Xue, Xiaogang; Xu, Jiwen; Wang, Hua; Wei, Bin
2018-02-01
Polymeric carbon nitride (CNxHy) has been facilely synthesized from dicyandiamide and functions as a solution-processed hole injection layer in organic light-emitting diodes (OLEDs). The measurements using X-ray diffraction, atomic force microscopy, X-ray photoelectron spectroscopy, ultraviolet photoelectron spectroscopy, and impedance spectroscopy elucidate that CNxHy exhibits superior film morphology and extra electric properties such as tailored work function and tunable hole injection. The luminous efficiency of CNxHy-based OLED is found to improve by 76.6% in comparison to the counterpart using favorite solution-processed poly(ethylene dioxythiophene):poly(styrene sulfonate) as the hole injection layer. Our results also pave a way for broadening carbon nitride applications in organic electronics using the solution process.
Integrability of the one dimensional Schrödinger equation
NASA Astrophysics Data System (ADS)
Combot, Thierry
2018-02-01
We present a definition of integrability for the one-dimensional Schrödinger equation, which encompasses all known integrable systems, i.e., systems for which the spectrum can be explicitly computed. For this, we introduce the class of rigid functions, built as Liouvillian functions, but containing all solutions of rigid differential operators in the sense of Katz, and a notion of natural of boundary conditions. We then make a complete classification of rational integrable potentials. Many new integrable cases are found, some of them physically interesting.
Process of making solar cell module
Packer, M.; Coyle, P.J.
1981-03-09
A process is presented for the manufacture of solar cell modules. A solution comprising a highly plasticized polyvinyl butyral is applied to a solar cell array. The coated array is dried and sandwiched between at last two sheets of polyvinyl butyral and at least two sheets of a rigid transparent member. The sandwich is laminated by the application of heat and pressure to cause fusion and bonding of the solar cell array with the rigid transparent members to produce a solar cell module.
Axisymmetric flows from fluid injection into a confined porous medium
NASA Astrophysics Data System (ADS)
Guo, Bo; Zheng, Zhong; Celia, Michael A.; Stone, Howard A.
2016-02-01
We study the axisymmetric flows generated from fluid injection into a horizontal confined porous medium that is originally saturated with another fluid of different density and viscosity. Neglecting the effects of surface tension and fluid mixing, we use the lubrication approximation to obtain a nonlinear advection-diffusion equation that describes the time evolution of the sharp fluid-fluid interface. The flow behaviors are controlled by two dimensionless groups: M, the viscosity ratio of displaced fluid relative to injected fluid, and Γ, which measures the relative importance of buoyancy and fluid injection. For this axisymmetric geometry, the similarity solution involving R2/T (where R is the dimensionless radial coordinate and T is the dimensionless time) is an exact solution to the nonlinear governing equation for all times. Four analytical expressions are identified as asymptotic approximations (two of which are new solutions): (i) injection-driven flow with the injected fluid being more viscous than the displaced fluid (Γ ≪ 1 and M < 1) where we identify a self-similar solution that indicates a parabolic interface shape; (ii) injection-driven flow with injected and displaced fluids of equal viscosity (Γ ≪ 1 and M = 1), where we find a self-similar solution that predicts a distinct parabolic interface shape; (iii) injection-driven flow with a less viscous injected fluid (Γ ≪ 1 and M > 1) for which there is a rarefaction wave solution, assuming that the Saffman-Taylor instability does not occur at the reservoir scale; and (iv) buoyancy-driven flow (Γ ≫ 1) for which there is a well-known self-similar solution corresponding to gravity currents in an unconfined porous medium [S. Lyle et al. "Axisymmetric gravity currents in a porous medium," J. Fluid Mech. 543, 293-302 (2005)]. The various axisymmetric flows are summarized in a Γ-M regime diagram with five distinct dynamic behaviors including the four asymptotic regimes and an intermediate regime. The implications of the regime diagram are discussed using practical engineering projects of geological CO2 sequestration, enhanced oil recovery, and underground waste disposal.
Damageable contact between an elastic body and a rigid foundation
NASA Astrophysics Data System (ADS)
Campo, M.; Fernández, J. R.; Silva, A.
2009-02-01
In this work, the contact problem between an elastic body and a rigid obstacle is studied, including the development of material damage which results from internal compression or tension. The variational problem is formulated as a first-kind variational inequality for the displacements coupled with a parabolic partial differential equation for the damage field. The existence of a unique local weak solution is stated. Then, a fully discrete scheme is introduced using the finite element method to approximate the spatial variable and an Euler scheme to discretize the time derivatives. Error estimates are derived on the approximate solutions, from which the linear convergence of the algorithm is deduced under suitable regularity conditions. Finally, three two-dimensional numerical simulations are performed to demonstrate the accuracy and the behaviour of the scheme.
Modeling Multibody Stage Separation Dynamics Using Constraint Force Equation Methodology
NASA Technical Reports Server (NTRS)
Tartabini, Paul V.; Roithmayr, Carlos M.; Toniolo, Matthew D.; Karlgaard, Christopher D.; Pamadi, Bandu N.
2011-01-01
This paper discusses the application of the constraint force equation methodology and its implementation for multibody separation problems using three specially designed test cases. The first test case involves two rigid bodies connected by a fixed joint, the second case involves two rigid bodies connected with a universal joint, and the third test case is that of Mach 7 separation of the X-43A vehicle. For the first two cases, the solutions obtained using the constraint force equation method compare well with those obtained using industry- standard benchmark codes. For the X-43A case, the constraint force equation solutions show reasonable agreement with the flight-test data. Use of the constraint force equation method facilitates the analysis of stage separation in end-to-end simulations of launch vehicle trajectories
General Solution of the Rayleigh Equation for the Description of Bubble Oscillations Near a Wall
NASA Astrophysics Data System (ADS)
Garashchuk, Ivan; Sinelshchikov, Dmitry; Kudryashov, Nikolay
2018-02-01
We consider a generalization of the Rayleigh equation for the description of the dynamics of a spherical gas bubble oscillating near an elastic or rigid wall. We show that in the non-dissipative case, i.e. neglecting the liquid viscosity and compressibility, it is possible to construct the general analytical solution of this equation. The corresponding general solution is expressed via the Weierstrass elliptic function. We analyze the dependence of this solution properties on the physical parameters.
NASA Astrophysics Data System (ADS)
Bonkobara, Yasuhiro; Mori, Hiroki; Kondou, Takahiro; Ayabe, Takashi
Self-synchronized phenomena generated in rotor-type oscillators mounted on a straight-line spring-mass system are investigated experimentally and analytically. In the present study, we examine the occurrence region and pattern of self-synchronization in two types of coupled oscillators: rigidly coupled oscillators and elastically coupled oscillators. It is clarified that the existence regions of stable solutions are governed mainly by the linear natural frequency of each spring-mass system. The results of numerical analysis confirm that the self-synchronized solutions of the elastically coupled oscillators correspond to those of the rigidly coupled oscillators. In addition, the results obtained in the present study are compared with the previously reported results for a metronome system and a moving apparatus and the different properties of the phenomena generated in the rotor-type oscillators and the pendulum-type oscillators are shown in terms of the construction of branches of self-synchronized solution and the stability.
Liu, Tianshu; Jagota, Anand; Hui, Chung-Yuen
2015-05-21
This article studies the effects of surface tension on the adhesive contact mechanics of a long rigid cylinder on an infinite half space comprising an incompressible elastic material. We present an exact solution based on small strain theory. The relationship between the indentation force and contact width was found to depend on a single dimensionless parameter ω = σ/[4(μR)(2/3)(W(ad)/2π)(1/3'), where R is the cylinder radius, Wad is the interfacial work of adhesion, and σ and μ are the surface tension and shear modulus of the half space, respectively. For small ω the solution reduces to the classical Johnson-Kendall-Roberts (JKR) theory, whereas for large ω the solution reduces to the small slope version of the Young-Dupre equation. The pull-off phenomenon was carefully examined and it was found that the contact width at pull-off reduces to zero when surface tension is larger than a critical value.
Inertial and viscoelastic forces on rigid colloids in microfluidic channels.
Howard, Michael P; Panagiotopoulos, Athanassios Z; Nikoubashman, Arash
2015-06-14
We perform hybrid molecular dynamics simulations to study the flow behavior of rigid colloids dispersed in a dilute polymer solution. The underlying Newtonian solvent and the ensuing hydrodynamic interactions are incorporated through multiparticle collision dynamics, while the constituent polymers are modeled as bead-spring chains, maintaining a description consistent with the colloidal nature of our system. We study the cross-stream migration of the solute particles in slit-like channels for various polymer lengths and colloid sizes and find a distinct focusing onto the channel center under specific solvent and flow conditions. To better understand this phenomenon, we systematically measure the effective forces exerted on the colloids. We find that the migration originates from a competition between viscoelastic forces from the polymer solution and hydrodynamically induced inertial forces. Our simulations reveal a significantly stronger fluctuation of the lateral colloid position than expected from thermal motion alone, which originates from the complex interplay between the colloid and polymer chains.
Maximum magnitude earthquakes induced by fluid injection
McGarr, Arthur F.
2014-01-01
Analysis of numerous case histories of earthquake sequences induced by fluid injection at depth reveals that the maximum magnitude appears to be limited according to the total volume of fluid injected. Similarly, the maximum seismic moment seems to have an upper bound proportional to the total volume of injected fluid. Activities involving fluid injection include (1) hydraulic fracturing of shale formations or coal seams to extract gas and oil, (2) disposal of wastewater from these gas and oil activities by injection into deep aquifers, and (3) the development of enhanced geothermal systems by injecting water into hot, low-permeability rock. Of these three operations, wastewater disposal is observed to be associated with the largest earthquakes, with maximum magnitudes sometimes exceeding 5. To estimate the maximum earthquake that could be induced by a given fluid injection project, the rock mass is assumed to be fully saturated, brittle, to respond to injection with a sequence of earthquakes localized to the region weakened by the pore pressure increase of the injection operation and to have a Gutenberg-Richter magnitude distribution with a b value of 1. If these assumptions correctly describe the circumstances of the largest earthquake, then the maximum seismic moment is limited to the volume of injected liquid times the modulus of rigidity. Observations from the available case histories of earthquakes induced by fluid injection are consistent with this bound on seismic moment. In view of the uncertainties in this analysis, however, this should not be regarded as an absolute physical limit.
Flow regimes for fluid injection into a confined porous medium
Zheng, Zhong; Guo, Bo; Christov, Ivan C.; ...
2015-02-24
We report theoretical and numerical studies of the flow behaviour when a fluid is injected into a confined porous medium saturated with another fluid of different density and viscosity. For a two-dimensional configuration with point source injection, a nonlinear convection–diffusion equation is derived to describe the time evolution of the fluid–fluid interface. In the early time period, the fluid motion is mainly driven by the buoyancy force and the governing equation is reduced to a nonlinear diffusion equation with a well-known self-similar solution. In the late time period, the fluid flow is mainly driven by the injection, and the governingmore » equation is approximated by a nonlinear hyperbolic equation that determines the global spreading rate; a shock solution is obtained when the injected fluid is more viscous than the displaced fluid, whereas a rarefaction wave solution is found when the injected fluid is less viscous. In the late time period, we also obtain analytical solutions including the diffusive term associated with the buoyancy effects (for an injected fluid with a viscosity higher than or equal to that of the displaced fluid), which provide the structure of the moving front. Numerical simulations of the convection–diffusion equation are performed; the various analytical solutions are verified as appropriate asymptotic limits, and the transition processes between the individual limits are demonstrated.« less
NASA Astrophysics Data System (ADS)
He, Liping; Lu, Gang; Chen, Dachuan; Li, Wenjun; Lu, Chunsheng
2017-07-01
This paper investigates the three-dimensional (3D) injection molding flow of short fiber-reinforced polymer composites using a smoothed particle hydrodynamics (SPH) simulation method. The polymer melt was modeled as a power law fluid and the fibers were considered as rigid cylindrical bodies. The filling details and fiber orientation in the injection-molding process were studied. The results indicated that the SPH method could effectively predict the order of filling, fiber accumulation, and heterogeneous distribution of fibers. The SPH simulation also showed that fibers were mainly aligned to the flow direction in the skin layer and inclined to the flow direction in the core layer. Additionally, the fiber-orientation state in the simulation was quantitatively analyzed and found to be consistent with the results calculated by conventional tensor methods.
Zhai, W; Gerard, P D; Pulikanti, R; Peebles, E D
2011-10-01
The effects of the in ovo injection of different carbohydrate solutions on the internal egg temperature (IT), hatchability, and time of hatch of embryonated Ross × Ross 708 broiler hatching eggs were determined. In addition, the BW, liver weight, yolk sac weight (YSW), and yolk-free BW (YFBW) of the embryos on d 19.5 of incubation and of the chicks on day of hatch were determined. Eggs containing live embryos were injected in the amnion on d 18.5 of incubation using an automated multiple-egg injector. Solution injections delivered 1.2 mL of physiological saline (0.85%) alone or with a supplemental carbohydrate. The following supplemental carbohydrates were separately dissolved in saline at a concentration of 0.3 g/mL: glucose, fructose, sucrose, maltose, and dextrin. Temperature transponders were implanted in the air cells of embryonated and nonembryonated eggs after in ovo injection for the detection of IT at 6, 14, and 22 h after injection. The IT of embryonated eggs was significantly greater than that of nonembryonated eggs at all 3 times after the treatment period. Eggs that were injected with saline with or without supplemental carbohydrates experienced a reduction in IT when compared with control eggs whose shells were perforated without solution delivery, and the decrease in IT was associated with a delay in hatch time. Liver weight was negatively related to YSW and positively related to YFBW, and YSW was negatively related to YFBW. Although the saline and carbohydrate solution injections increased chick BW compared with noninjected controls, chick YFBW was decreased in the maltose- and sucrose-injected groups. In conclusion, the injection of 1.2 mL of saline with or without supplemental carbohydrates lowered embryonic metabolism, as reflected by a lower IT and a delay in time of hatch. However, effects of the different carbohydrate solutions on yolk absorption and tissue deposition in yolk-free embryos varied. These results suggest that lower volumes for solutions containing maltose, sucrose, or fructose should be considered for in ovo injection.
SOLUTIONS APPROXIMATING SOLUTE TRANSPORT IN A LEAKY AQUIFER RECEIVING WASTEWATER INJECTION
A mathematical model amenable to analytical solution techniques is developed for the investigation of contaminant transport from an injection well into a leaky aquifer system, which comprises a pumped and an unpumped aquifer connected to each other by an aquitard. A steady state ...
Masters of defence: biomechanics of stinging nettles
NASA Astrophysics Data System (ADS)
Jensen, Kaare H.; Knoblauch, Jan
2017-11-01
The techniques employed by plants and animals to defend themselves are very varied. Some involve extremely refined armaments. Stinging nettles employ hollow needle-like stinging hairs constructed from silica, the mineral from which we make glass, and they are filled with poison. The hairs are remarkably rigid and rarely break. Yet the tip is so sharp that the slightest touch cuts human skin, and so fragile that it breaks at that touch and releases poison into the wound. How the seemingly antagonist mechanical functions of rigidity and fragility are achieved, however, is unknown. We combine experiments on real and synthetic stingers to elucidate the poison injection mechanism. The design of plant stingers is compared to other natural systems and optimal stinging strategies are discussed. This work was supported by a research Grant (13166) from VILLUM FONDEN.
Sun, J; Wang, T; Li, Z D; Shao, Y; Zhang, Z Y; Feng, H; Zou, D H; Chen, Y J
2017-12-01
To reconstruct a vehicle-bicycle-cyclist crash accident and analyse the injuries using 3D laser scanning technology, multi-rigid-body dynamics and optimized genetic algorithm, and to provide biomechanical basis for the forensic identification of death cause. The vehicle was measured by 3D laser scanning technology. The multi-rigid-body models of cyclist, bicycle and vehicle were developed based on the measurements. The value range of optimal variables was set. A multi-objective genetic algorithm and the nondominated sorting genetic algorithm were used to find the optimal solutions, which were compared to the record of the surveillance video around the accident scene. The reconstruction result of laser scanning on vehicle was satisfactory. In the optimal solutions found by optimization method of genetic algorithm, the dynamical behaviours of dummy, bicycle and vehicle corresponded to that recorded by the surveillance video. The injury parameters of dummy were consistent with the situation and position of the real injuries on the cyclist in accident. The motion status before accident, damage process by crash and mechanical analysis on the injury of the victim can be reconstructed using 3D laser scanning technology, multi-rigid-body dynamics and optimized genetic algorithm, which have application value in the identification of injury manner and analysis of death cause in traffic accidents. Copyright© by the Editorial Department of Journal of Forensic Medicine
A MATLAB-based eye tracking control system using non-invasive helmet head restraint in the macaque.
De Luna, Paolo; Mohamed Mustafar, Mohamed Faiz Bin; Rainer, Gregor
2014-09-30
Tracking eye position is vital for behavioral and neurophysiological investigations in systems and cognitive neuroscience. Infrared camera systems which are now available can be used for eye tracking without the need to surgically implant magnetic search coils. These systems are generally employed using rigid head fixation in monkeys, which maintains the eye in a constant position and facilitates eye tracking. We investigate the use of non-rigid head fixation using a helmet that constrains only general head orientation and allows some freedom of movement. We present a MATLAB software solution to gather and process eye position data, present visual stimuli, interact with various devices, provide experimenter feedback and store data for offline analysis. Our software solution achieves excellent timing performance due to the use of data streaming, instead of the traditionally employed data storage mode for processing analog eye position data. We present behavioral data from two monkeys, demonstrating that adequate performance levels can be achieved on a simple fixation paradigm and show how performance depends on parameters such as fixation window size. Our findings suggest that non-rigid head restraint can be employed for behavioral training and testing on a variety of gaze-dependent visual paradigms, reducing the need for rigid head restraint systems for some applications. While developed for macaque monkey, our system of course can work equally well for applications in human eye tracking where head constraint is undesirable. Copyright © 2014. Published by Elsevier B.V.
An analytical solution for transient flow of Bingham viscoplastic materials in rock fractures
Amadei, B.; Savage, W.Z.
2001-01-01
We present below an analytical solution to model the one-dimensional transient flow of a Bingham viscoplastic material in a fracture with parallel walls (smooth or rough) that is subjected to an applied pressure gradient. The solution models the acceleration and the deceleration of the material as the pressure gradient changes with time. Two cases are considered: A pressure gradient applied over a finite time interval and an applied pressure gradient that is constant over time. The solution is expressed in dimensionless form and can therefore be used for a wide range of Bingham viscoplastic materials. The solution is also capable of capturing the transition that takes place in a fracture between viscoplastic flow and rigid plug flow. Also, it shows the development of a rigid central layer in fractures, the extent of which depends on the fluid properties (viscosity and yield stress), the magnitude of the pressure gradient, and the fracture aperture and surface roughness. Finally, it is shown that when a pressure gradient is applied and kept constant, the solution for the fracture flow rate converges over time to a steady-state solution that can be defined as a modified cubic law. In this case, the fracture transmissivity is found to be a non-linear function of the head gradient. This solution provides a tool for a better understanding of the flow of Bingham materials in rock fractures, interfaces, and cracks. ?? 2001 Elsevier Science Ltd. All rights reserved.
Syringe injectable electronics
Hong, Guosong; Zhou, Tao; Jin, Lihua; Duvvuri, Madhavi; Jiang, Zhe; Kruskal, Peter; Xie, Chong; Suo, Zhigang; Fang, Ying; Lieber, Charles M.
2015-01-01
Seamless and minimally-invasive three-dimensional (3D) interpenetration of electronics within artificial or natural structures could allow for continuous monitoring and manipulation of their properties. Flexible electronics provide a means for conforming electronics to non-planar surfaces, yet targeted delivery of flexible electronics to internal regions remains difficult. Here, we overcome this challenge by demonstrating syringe injection and subsequent unfolding of submicrometer-thick, centimeter-scale macroporous mesh electronics through needles with a diameter as small as 100 micrometers. Our results show that electronic components can be injected into man-made and biological cavities, as well as dense gels and tissue, with > 90% device yield. We demonstrate several applications of syringe injectable electronics as a general approach for interpenetrating flexible electronics with 3D structures, including (i) monitoring of internal mechanical strains in polymer cavities, (ii) tight integration and low chronic immunoreactivity with several distinct regions of the brain, and (iii) in vivo multiplexed neural recording. Moreover, syringe injection enables delivery of flexible electronics through a rigid shell, delivery of large volume flexible electronics that can fill internal cavities and co-injection of electronics with other materials into host structures, opening up unique applications for flexible electronics. PMID:26053995
Syringe-injectable electronics.
Liu, Jia; Fu, Tian-Ming; Cheng, Zengguang; Hong, Guosong; Zhou, Tao; Jin, Lihua; Duvvuri, Madhavi; Jiang, Zhe; Kruskal, Peter; Xie, Chong; Suo, Zhigang; Fang, Ying; Lieber, Charles M
2015-07-01
Seamless and minimally invasive three-dimensional interpenetration of electronics within artificial or natural structures could allow for continuous monitoring and manipulation of their properties. Flexible electronics provide a means for conforming electronics to non-planar surfaces, yet targeted delivery of flexible electronics to internal regions remains difficult. Here, we overcome this challenge by demonstrating the syringe injection (and subsequent unfolding) of sub-micrometre-thick, centimetre-scale macroporous mesh electronics through needles with a diameter as small as 100 μm. Our results show that electronic components can be injected into man-made and biological cavities, as well as dense gels and tissue, with >90% device yield. We demonstrate several applications of syringe-injectable electronics as a general approach for interpenetrating flexible electronics with three-dimensional structures, including (1) monitoring internal mechanical strains in polymer cavities, (2) tight integration and low chronic immunoreactivity with several distinct regions of the brain, and (3) in vivo multiplexed neural recording. Moreover, syringe injection enables the delivery of flexible electronics through a rigid shell, the delivery of large-volume flexible electronics that can fill internal cavities, and co-injection of electronics with other materials into host structures, opening up unique applications for flexible electronics.
Syringe-injectable electronics
NASA Astrophysics Data System (ADS)
Liu, Jia; Fu, Tian-Ming; Cheng, Zengguang; Hong, Guosong; Zhou, Tao; Jin, Lihua; Duvvuri, Madhavi; Jiang, Zhe; Kruskal, Peter; Xie, Chong; Suo, Zhigang; Fang, Ying; Lieber, Charles M.
2015-07-01
Seamless and minimally invasive three-dimensional interpenetration of electronics within artificial or natural structures could allow for continuous monitoring and manipulation of their properties. Flexible electronics provide a means for conforming electronics to non-planar surfaces, yet targeted delivery of flexible electronics to internal regions remains difficult. Here, we overcome this challenge by demonstrating the syringe injection (and subsequent unfolding) of sub-micrometre-thick, centimetre-scale macroporous mesh electronics through needles with a diameter as small as 100 μm. Our results show that electronic components can be injected into man-made and biological cavities, as well as dense gels and tissue, with >90% device yield. We demonstrate several applications of syringe-injectable electronics as a general approach for interpenetrating flexible electronics with three-dimensional structures, including (1) monitoring internal mechanical strains in polymer cavities, (2) tight integration and low chronic immunoreactivity with several distinct regions of the brain, and (3) in vivo multiplexed neural recording. Moreover, syringe injection enables the delivery of flexible electronics through a rigid shell, the delivery of large-volume flexible electronics that can fill internal cavities, and co-injection of electronics with other materials into host structures, opening up unique applications for flexible electronics.
NASA Astrophysics Data System (ADS)
Roh, Jeongkyun; Kim, Hyeok; Park, Myeongjin; Kwak, Jeonghun; Lee, Changhee
2017-10-01
Interface engineering for the improved injection properties of all-solution-processed n-type organic field-effect transistors (OFETs) arising from the use of an inkjet-printed ZnO electron injection layer were demonstrated. The characteristics of ZnO in terms of electron injection and transport were investigated, and then we employed ZnO as the electron injection layer via inkjet-printing during the fabrication of all-solution-processed, n-type OFETs. With the inkjet-printed ZnO electron injection layer, the devices exhibited approximately five-fold increased mobility (0.0058 cm2/V s to 0.030 cm2/V s), more than two-fold increased charge concentration (2.76 × 1011 cm-2 to 6.86 × 1011 cm-2), and two orders of magnitude reduced device resistance (120 MΩ cm to 3 MΩ cm). Moreover, n-type polymer form smoother film with ZnO implying denser packing of polymer, which results in higher mobility.
Numerical algorithm for rigid body position estimation using the quaternion approach
NASA Astrophysics Data System (ADS)
Zigic, Miodrag; Grahovac, Nenad
2017-11-01
This paper deals with rigid body attitude estimation on the basis of the data obtained from an inertial measurement unit mounted on the body. The aim of this work is to present the numerical algorithm, which can be easily applied to the wide class of problems concerning rigid body positioning, arising in aerospace and marine engineering, or in increasingly popular robotic systems and unmanned aerial vehicles. Following the considerations of kinematics of rigid bodies, the relations between accelerations of different points of the body are given. A rotation matrix is formed using the quaternion approach to avoid singularities. We present numerical procedures for determination of the absolute accelerations of the center of mass and of an arbitrary point of the body expressed in the inertial reference frame, as well as its attitude. An application of the algorithm to the example of a heavy symmetrical gyroscope is presented, where input data for the numerical procedure are obtained from the solution of differential equations of motion, instead of using sensor measurements.
NASA Astrophysics Data System (ADS)
Le Merrer, Marie; Cohen-Addad, Sylvie; Höhler, Reinhard
2013-08-01
In aqueous foams, the diffusive gas transfer among neighboring bubbles drives a coarsening process which is accompanied by intermittent rearrangements of the structure. Using time-resolved diffusing-wave spectroscopy, we probe the dynamics of these events as a function of the rigidity of the gas-liquid interfaces, liquid viscosity, bubble size, and confinement pressure. We present in detail two independent techniques for analyzing the light scattering data, from which we extract the rearrangement duration. Our results show that interfacial rheology has a major impact on this duration. In the case of low interfacial rigidity, the rearrangements strongly slow down as the pressure is decreased close to the value zero where the bubble packing unjams. In contrast, if the interfaces are rigid, rearrangement durations are independent of the confinement pressure in the same investigated range. Using scaling arguments, we discuss dissipation mechanisms that may explain the observed dependency of the rearrangement dynamics on foam structure, pressure, and physicochemical solution properties.
A structural design decomposition method utilizing substructuring
NASA Technical Reports Server (NTRS)
Scotti, Stephen J.
1994-01-01
A new method of design decomposition for structural analysis and optimization is described. For this method, the structure is divided into substructures where each substructure has its structural response described by a structural-response subproblem, and its structural sizing determined from a structural-sizing subproblem. The structural responses of substructures that have rigid body modes when separated from the remainder of the structure are further decomposed into displacements that have no rigid body components, and a set of rigid body modes. The structural-response subproblems are linked together through forces determined within a structural-sizing coordination subproblem which also determines the magnitude of any rigid body displacements. Structural-sizing subproblems having constraints local to the substructures are linked together through penalty terms that are determined by a structural-sizing coordination subproblem. All the substructure structural-response subproblems are totally decoupled from each other, as are all the substructure structural-sizing subproblems, thus there is significant potential for use of parallel solution methods for these subproblems.
Simple models for rope substructure mechanics: application to electro-mechanical lifts
NASA Astrophysics Data System (ADS)
Herrera, I.; Kaczmarczyk, S.
2016-05-01
Mechanical systems modelled as rigid mass elements connected by tensioned slender structural members such as ropes and cables represent quite common substructures used in lift engineering and hoisting applications. Special interest is devoted by engineers and researchers to the vibratory response of such systems for optimum performance and durability. This paper presents simplified models that can be employed to determine the natural frequencies of systems having substructures of two rigid masses constrained by tensioned rope/cable elements. The exact solution for free un-damped longitudinal displacement response is discussed in the context of simple two-degree-of-freedom models. The results are compared and the influence of characteristics parameters such as the ratio of the average mass of the two rigid masses with respect to the rope mass and the deviation ratio of the two rigid masses with respect to the average mass is analyzed. This analysis gives criteria for the application of such simplified models in complex elevator and hoisting system configurations.
NASA Astrophysics Data System (ADS)
Duchêne, Vincent
2014-08-01
The rigid-lid approximation is a commonly used simplification in the study of density-stratified fluids in oceanography. Roughly speaking, one assumes that the displacements of the surface are negligible compared with interface displacements. In this paper, we offer a rigorous justification of this approximation in the case of two shallow layers of immiscible fluids with constant and quasi-equal mass density. More precisely, we control the difference between the solutions of the Cauchy problem predicted by the shallow-water (Saint-Venant) system in the rigid-lid and free-surface configuration. We show that in the limit of a small density contrast, the flow may be accurately described as the superposition of a baroclinic (or slow) mode, which is well predicted by the rigid-lid approximation, and a barotropic (or fast) mode, whose initial smallness persists for large time. We also describe explicitly the first-order behavior of the deformation of the surface and discuss the case of a nonsmall initial barotropic mode.
NASA Astrophysics Data System (ADS)
Mohammed, O.; Mumford, K. G.; Sleep, B. E.
2016-12-01
Gases are commonly introduced into the subsurface via external displacement (drainage). However, gases can also be produced by internal drainage (exsolution). One example is the injection of reactive solutions for in situ groundwater remediation, such as nanoscale zero-valent iron (nzvi), which produces hydrogen gas (H2). Effective implementation of nzvi requires an understanding of H2 gas generation and dynamics, and their effects on aqueous permeability, contaminant mass transfer and potential flow diversion. Several studies have reported using excess sodium borohydride (NaBH4) in nzvi applications to promote complete reaction and to ensure uniform nzvi particle growth, which also produces H2 gas. The aim of this study was to visualize and quantify H2 produced by exsolution from the injection of NaBH4 and nzvi solutions into homogeneous sands, and to investigate the reduction of hydraulic conductivity caused by the H2 gas and the subsequent increase in hydraulic conductivity as the gas dissolved. Bench-scale experiments were performed using cold (4 °C) NaBH4 solutions injected in sand packed in a 22 cm × 34 cm × 1 cm flow cell. The injected solution was allowed to warm to room temperature, for controlled production of a uniform distribution of exsolved gas. A light transmission method was used to quantify gas production and dissolution over time. The results indicate a reduction of hydraulic conductivity due to the existence of H2 and increased hydraulic conductivity as H2 gas dissolves, which could be represented using traditional relative permeability expressions. Additional experiments were performed in the flow cell to compare H2 gas exsolving from nzvi and NaBH4 solutions injected as either a point injection or a well injection. The results indicated greater amounts of H2 gas produced when injecting nzvi solutions prepared with high concentrations of excess NaBH4. H2 gas pooling at the top of the flow cell, and H2 gas trapped near the injection point created preferential flow through the middle of the cell. These results demonstrate that H2 gas produced during remediation by nzvi injection can be controlled by limiting the excess NaBH4 concentrations. The trapped H2 gas produced by injection of nzvi, or NaBH4 alone may provide a source of H2 that could facilitate bioremediation as a secondary treatment.
Haemoglobinuria caused by propylene glycol in sheep
Potter, B. J.
1958-01-01
Haemoglobinuria occurred in sheep anaesthetized by an intravenous injection of pentobarbitone sodium containing propylene glycol: an equivalent dose failed to cause haemoglobinuria in rabbits. Intravenous injection of an aqueous solution of 20% propylene glycol caused haemoglobinaemia and haemoglobinuria in sheep. Neither distilled water nor 20% glycerol in water administered under identical conditions produced these effects. Haemoglobinuria occurred on some occasions when an aqueous 20% solution of propylene glycol was administered to sheep after an injection of saline: it never occurred when a solution of 20% propylene glycol prepared with physiological saline was injected. It is suggested that saline may protect against the haemolytic action of propylene glycol in sheep and that propylene glycol should be avoided as a menstruum for pharmaceutical preparations to be used for injection into the blood stream of these animals. PMID:13618540
Stability of tacrolimus solutions in polyolefin containers.
Lee, Jun H; Goldspiel, Barry R; Ryu, Sujung; Potti, Gopal K
2016-02-01
Results of a study to determine the stability of tacrolimus solutions stored in polyolefin containers under various temperature conditions are reported. Triplicate solutions of tacrolimus (0.001, 0.01, and 0.1 mg/mL) in 0.9% sodium chloride injection or 5% dextrose injection were prepared in polyolefin containers. Some samples were stored at room temperature (20-25 °C); others were refrigerated (2-8 °C) for 20 hours and then stored at room temperature for up to 28 hours. The solutions were analyzed by stability-indicating high-performance liquid chromatography (HPLC) assay at specified time points over 48 hours. Solution pH was measured and containers were visually inspected at each time point. Stability was defined as retention of at least 90% of the initial tacrolimus concentration. All tested solutions retained over 90% of the initial tacrolimus concentration at all time points, with the exception of the 0.001-mg/mL solution prepared in 0.9% sodium chloride injection, which was deemed unstable beyond 24 hours. At all evaluated concentrations, mean solution pH values did not change significantly over 48 hours; no particle formation was detected. During storage in polyolefin bags at room temperature, a 0.001-mg/mL solution of tacrolimus was stable for 24 hours when prepared in 0.9% sodium chloride injection and for at least 48 hours when prepared in 5% dextrose injection. Solutions of 0.01 and 0.1 mg/mL prepared in either diluent were stable for at least 48 hours, and the 0.01-mg/mL tacrolimus solution was also found to be stable throughout a sequential temperature protocol. Copyright © 2016 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
Geomagnetic cutoffs: A review for space dosimetry applications
NASA Astrophysics Data System (ADS)
Smart, D. F.; Shea, M. A.
1994-10-01
The earth's magnetic field acts as a shield against charged particle radiation from interplanetary space, technically described as the geomagnetic cutoff. The cutoff rigidity problem (except for the dipole special case) has 'no solution in closed form'. The dipole case yields the Stormer equation which has been repeatedly applied to the earth in hopes of providing useful approximations of cutoff rigidities. Unfortunately the earth's magnetic field has significant deviations from dipole geometry, and the Stormer cutoffs are not adequate for most applications. By application of massive digital computer power it is possible to determine realistic geomagnetic cutoffs derived from high order simulation of the geomagnetic field. Using this technique, 'world-grids' of directional cutoffs for the earth's surface and for a limited number of satellite altitudes have been derived. However, this approach is so expensive and time comsuming it is impractical for most spacecraft orbits, and approximations must be used. The world grids of cutoff rigidities are extensively used as lookup tables, normalization points and interpolation aids to estimate the effective geomagnetic cutoff rigidity of a specific location in space. We review the various options for estimating the cutoff rigidity for earth-orbiting satellites.
Porogranular materials composed of elastic Helmholtz resonators for acoustic wave absorption.
Griffiths, Stéphane; Nennig, Benoit; Job, Stéphane
2017-01-01
A theoretical and experimental study of the acoustic absorption of granular porous media made of non-cohesive piles of spherical shells is presented. These shells are either rigid or elastic, possibly drilled with a neck (Helmholtz resonators), and either porous or impervious. A description is given of acoustic propagation through these media using the effective medium models proposed by Johnson (rigid particles) and Boutin (rigid Helmholtz resonators), which are extended to the configurations studied in this work. A solution is given for the local equation of elasticity of a shell coupled to the viscous flow of air through the neck and the micropores. The models and the simulations are compared to absorption spectra measured in reflection in an impedance tube. The effective medium models and the measurements show excellent agreement for configurations made of rigid particles and rigid Helmholtz resonators that induce an additional peak of absorption at low frequency. A shift of the Helmholtz resonance toward low frequencies, due to the softness of the shells is revealed by the experiments for elastic shells made of soft elastomer and is well reproduced by the simulations. It is shown that microporous shells enhance and broaden acoustic absorption compared to stiff or elastic resonators.
Topological classification of the Goryachev integrable case in rigid body dynamics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nikolaenko, S S
2016-01-31
A topological analysis of the Goryachev integrable case in rigid body dynamics is made on the basis of the Fomenko-Zieschang theory. The invariants (marked molecules) which are obtained give a complete description, from the standpoint of Liouville classification, of the systems of Goryachev type on various level sets of the energy. It turns out that on appropriate energy levels the Goryachev case is Liouville equivalent to many classical integrable systems and, in particular, the Joukowski, Clebsch, Sokolov and Kovalevskaya-Yehia cases in rigid body dynamics, as well as to some integrable billiards in plane domains bounded by confocal quadrics -- in othermore » words, the foliations given by the closures of generic solutions of these systems have the same structure. Bibliography: 15 titles.« less
Yuan, Chunxue; Saito, Shohei; Camacho, Cristopher; Irle, Stephan; Hisaki, Ichiro; Yamaguchi, Shigehiro
2013-06-19
We have designed and synthesized a π-conjugated system that consists of a flexible and nonplanar π joint and two emissive rigid and planar wings. This molecular system exhibits respectively red, green, and blue (RGB) emission from a single-component luminophore in different environments, namely in polymer matrix, in solution, and in crystals. The flexible unit gives rise to a dynamic conformational change in the excited state from a nonplanar V-shaped structure to a planar structure, leading to a dual fluorescence of blue and green colors. The rigid and planar moieties favor the formation of a two-fold π-stacked array of the V-shaped molecules in the crystalline state, which produces a red excimer-like emission. These RGB emissions are attained without changing the excitation energy.
Zhao, Sipei; Qiu, Xiaojun; Cheng, Jianchun
2015-09-01
This paper proposes a different method for calculating a sound field diffracted by a rigid barrier based on the integral equation method, where a virtual boundary is assumed above the rigid barrier to divide the whole space into two subspaces. Based on the Kirchhoff-Helmholtz equation, the sound field in each subspace is determined with the source inside and the boundary conditions on the surface, and then the diffracted sound field is obtained by using the continuation conditions on the virtual boundary. Simulations are carried out to verify the feasibility of the proposed method. Compared to the MacDonald method and other existing methods, the proposed method is a rigorous solution for whole space and is also much easier to understand.
Decontaminating materials used in ground water sampling devices: Organic contaminants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parker, L.V.; Ranney, T.A.
2000-12-31
In these studies, the efficiency of various decontamination protocols was tested on small pieces of materials commonly used in ground water sampling devices. Three materials, which ranged in ability to sorb organic solutes, were tested: stainless steel (SS), rigid polyvinyl chloride (PVC), and polytetrafluoroethylene (PTFE). The test pieces were exposed to two aqueous test solutions: One contained three volatile organic compounds (VOCs) and one nitroaromatic compound, and the other contained four pesticides. Also, three types of polymetic tubing were exposed to pesticide solutions. Generally, the contact times were 10 minutes and 24 hours for sorption and desorption. The contaminants weremore » removed from the nonpermeable SS and the less-sorptive rigid PVC test pieces simply by washing with a hot detergent solution and rinsing with hot water. Additional treatment was required for the PTFE test pieces exposed to the VOCs and for the low-density polyethylene (LDPE) tubing exposed to the pesticide test solution. Solvent rinsing did not improve removal of the three VOCs form the PTFE and only marginally improved removal of the residual pesticides from the LDPE. However, a hot water and detergent wash and rinse followed by oven drying at approximately 105 C was effective for removing the VOCs from the PTFE and substantially reduced pesticide contamination from the LDPE.« less
Elastic layer under axisymmetric indentation and surface energy effects
NASA Astrophysics Data System (ADS)
Intarit, Pong-in; Senjuntichai, Teerapong; Rungamornrat, Jaroon
2018-04-01
In this paper, a continuum-based approach is adopted to investigate the contact problem of an elastic layer with finite thickness and rigid base subjected to axisymmetric indentation with the consideration of surface energy effects. A complete Gurtin-Murdoch surface elasticity is employed to consider the influence of surface stresses. The indentation problem of a rigid frictionless punch with arbitrary axisymmetric profiles is formulated by employing the displacement Green's functions, derived with the aid of Hankel integral transform technique. The problem is solved by assuming the contact pressure distribution in terms of a linear combination of admissible functions and undetermined coefficients. Those coefficients are then obtained by employing a collocation technique and an efficient numerical quadrature scheme. The accuracy of proposed solution technique is verified by comparing with existing solutions for rigid indentation on an elastic half-space. Selected numerical results for the indenters with flat-ended cylindrical and paraboloidal punch profiles are presented to portray the influence of surface energy effects on elastic fields of the finite layer. It is found that the presence of surface stresses renders the layer stiffer, and the size-dependent behavior of elastic fields is observed in the present solutions. In addition, the surface energy effects become more pronounced with smaller contact area; thus, the influence of surface energy cannot be ignored in the analysis of indentation problem especially when the indenter size is very small such as in the case of nanoindentation.
Experimental study of the bending elasticity of charged lipid bilayers in aqueous solutions with pH5
NASA Astrophysics Data System (ADS)
Mitkova, D.; Stoyanova-Ivanova, A.; Ermakov, Yu A.; Vitkova, V.
2012-12-01
Exposure to high concentrations of contaminations due to air polluting gases, vapours and aerosols and possibly altering the normal pH in the body could lead to undesirable changes in the properties of biological cells. Here, we study experimentally the mechanical properties of synthetic phospholipid bilayers containing increasing molar fractions (up to 0.15) of charged lipid (synthetic phosphatidylserine) in aqueous solutions with controlled ionic strength and at pH 5, which is slightly lower than the physiological values of pH. Our observations in phase contrast and fluorescence testified to the coexistence of two phases in membranes for temperatures below 29°C. Micro-sized inhomogeneities in vesicle membranes were systematically observed at temperatures lower than 29°C and for molar fractions of phosphatidylserine in the bilayer higher than 0.1. For the quantitative determination of the membrane bending rigidity, we applied thermal fluctuation analysis of the shape of quasispherical lipid vesicles. As far as the liquid-crystalline state of the bilayer is a necessary condition for the application of the experimental method, only vesicles satisfying this requirement were processed for determination of their membrane bending rigidity. The value obtained for the bending modulus of bilayers with 0.15 molar content of charged lipid is about two times higher than the bending modulus of uncharged membranes in the same bathing solution. These findings are in qualitative agreement with our previous results for the bending rigidity of charged bilayers, measured by vesicle micromanipulation.
Kinoshita, Kazuhiko; Hibi, Hideharu; Yamada, Yoichi; Ueda, Minoru
2008-01-01
Bilateral maxillary distraction was performed at a higher rate in rabbits to determine whether locally applied tissue-engineered osteogenic material (TEOM) enhances bone regeneration. The material was an injectable gel composed of autologous mesenchymal stem cells, which were cultured then induced to be osteogenic in character, and platelet-rich plasma (PRP). After a 5-day latency period, distraction devices were activated at a rate of 2.0 mm once daily for 4 days. Twelve rabbits were divided into 2 groups. At the end of distraction, the experimental group of rabbits received an injection of TEOM into the distracted tissue on one side, whereas, saline solution was injected into the distracted tissue on the contralateral side as the internal control. An additional control group received an injection of PRP or saline solution into the distracted tissue in the same way as the experimental group. The distraction regenerates were assessed by radiological and histomorphometric analyses. The radiodensity of the distraction gap injected with TEOM was significantly higher than that injected with PRP or saline solution at 2, 3, and 4 weeks postdistraction. The histomorphometric analysis also showed that both new bone zone and bony content in the distraction gap injected with TEOM were significantly increased when compared with PRP or saline solution. Our results demonstrated that the distraction gap injected with TEOM showed significant new bone formation. Therefore, injections of TEOM may be able to compensate for insufficient distraction gaps.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jung, Yoojin
In this study, we have developed an analytical solution for thermal single-well injection-withdrawal tests in horizontally fractured reservoirs where fluid flow through the fracture is radial. The dimensionless forms of the governing equations and the initial and boundary conditions in the radial flow system can be written in a form identical to those in the linear flow system developed by Jung and Pruess [Jung, Y., and K. Pruess (2012), A Closed-Form Analytical Solution for Thermal Single-Well Injection-Withdrawal Tests, Water Resour. Res., 48, W03504, doi:10.1029/2011WR010979], and therefore the analytical solutions developed in Jung and Pruess (2012) can be applied to computemore » the time dependence of temperature recovery at the injection/withdrawal well in a horizontally oriented fracture with radial flow.« less
Fox, Laura M; Wilder, Alyson G; Foushee, Jaime A
2013-03-15
The physical compatibility of various drugs with neonatal total parenteral nutrient (TPN) solution during simulated Y-site administration was evaluated. Study drugs were selected based on the lack of compatibility data with them and neonatal TPN solution and the frequency of use in a local neonatal unit. These drugs included amiodarone, caffeine citrate, clindamycin, enalaprilat, epinephrine, fluconazole, fosphenytoin sodium, hydrocortisone, metoclopramide, midazolam, pentobarbital, phenobarbital, and rifampin. Equal volumes of neonatal TPN solution or sterile water for injection were combined with study drugs or sterile water for injection at concentrations used clinically in neonates. Each test was performed in triplicate. The samples were examined via turbidimetric analysis and visually against light and dark backgrounds immediately after mixing and at 0.25, 0.5, 1, 2, and 3 hours after mixing. Analysis of variance was used to determine statistically significant differences between the test and control solutions. Many of the drugs studied exhibited no visual or turbidimetric evidence of incompatibility when combined with neonatal TPN solution for up to three hours in a simulated Y-site injection. Pentobarbital, phenobarbital, and rifampin formed visible precipitation immediately after mixing with the neonatal TPN solution. Caffeine citrate, clindamycin, enalaprilat, epinephrine, fluconazole, fosphenytoin sodium, hydrocortisone, metoclopramide, and midazolam exhibited no visual or turbidimetric evidence of incompatibility when combined with a neonatal TPN solution for up to three hours in a simulated Y-site injection. Amiodarone, pentobarbital, phenobarbital, and rifampin were not compatible with the neonatal TPN solution and should not be coadministered via Y-site injection.
NASA Technical Reports Server (NTRS)
Kussner, H G
1937-01-01
The present report deals with a number of the main problems requiring solution in the development of helicopters and concerning the lift, flying performance, stability, and drive. A complete solution is given for the stability of the helicopter with rigid blades and control surfaces. With a view to making a direct-lift propeller sufficient without the addition of auxiliary propellers, the "flapping drive" is assessed and its efficiency calculated.
Performance of journal bearings with semi-compressible fluids
NASA Technical Reports Server (NTRS)
Carpino, M.; Peng, J.-P.
1991-01-01
Cryogenic fluids in isothermal rigid surface and foil type journal bearings can sometimes be treated as semicompressible fluids. In these applications, the fluid density is a function of the pressure. At low pressures, the fluids can change from a liquid to a saturated liquid-vapor phase. The performance of a rigid surface journal bearing with an idealized semicompressible fluid is discussed. Pressure solutions are based upon a Reynolds equation which includes the effects of a compressibility via the bulk modulus of the fluid. Results are contrasted with the performance of isothermal constant property incompressible fluids.
Vibrations of a thin cylindrical shell stiffened by rings with various stiffness
NASA Astrophysics Data System (ADS)
Nesterchuk, G. A.
2018-05-01
The problem of vibrations of a thin-walled elastic cylindrical shell reinforced by frames of different rigidity is investigated. The solution for the case of the clamped shell edges was obtained by asymptotic methods and refined by the finite element method. Rings with zero eccentricity and stiffness varying along the generatrix of the shell cylinder are considered. Varying the optimal coefficients of the distribution functions of the rigidity of the frames and finding more precise parameters makes it possible to find correction factors for analytical formulas of approximate calculation.
Gratings Fabricated on Flat Surfaces and Reproduced on Non-Flat Substrates
NASA Technical Reports Server (NTRS)
Content, David; Iazikov, Dmitri; Mossberg, Thomas W.; Greiner, Christopher M.
2009-01-01
A method has been developed for fabricating gratings on flat substrates, and then reproducing the groove pattern on a curved (concave or convex) substrate and a corresponding grating device. First, surface relief diffraction grating grooves are formed on flat substrates. For example, they may be fabricated using photolithography and reactive ion etching, maskless lithography, holography, or mechanical ruling. Then, an imprint of the grating is made on a deformable substrate, such as plastic, polymer, or other materials using thermoforming, hot or cold embossing, or other methods. Interim stamps using electroforming, or other methods, may be produced for the imprinting process or if the same polarity of the grating image is required. The imprinted, deformable substrate is then attached to a curved, rigid substrate using epoxy or other suitable adhesives. The imprinted surface is facing away from the curved rigid substrate. As an alternative fabrication method, after grating is imprinted on the deformable substrate as described above, the grating may be coated with thin conformal conductive layer (for example, using vacuum deposition of gold). Then the membrane may be mounted over an opening in a pressured vessel in a manner of a membrane on a drum, grating side out. The pressure inside of the vessel may be changed with respect to the ambient pressure to produce concave or convex membrane surface. The shape of the opening may control the type of the surface curvature (for example, a circular opening would create spherical surface, oval opening would create toroidal surface, etc.). After that, well-known electroforming methods may be used to create a replica of the grating on the concave or convex membrane. For example, the pressure vessel assembly may be submerged into an electro-forming solution and negative electric potential applied to the metal coated membrane using an insulated wire. Positive electric potential may be then applied to a nickel or other metal plate submerged into the same solution. Metal ions would transfer from the plate through the solution into the membrane, producing high fidelity metal replica of the grating on the membrane. In one variation, an adhesive may be deposited on the deformable substrate, and then cured without touching the rigid, curved substrate. Edges of the deformable substrate may be attached to the rigid substrate to ensure uniform deformation of the deformable substrate. The assembly may be performed in vacuum, and then taken out to atmospheric pressure conditions to ensure that no air is trapped between the deformable and rigid substrates. Alternatively, a rigid surface with complementary curvature to the rigid substrate may be used to ensure uniform adhesion of the deformable substrate to the rigid substrate. Liquid may be applied to the surface of the deformable substrate to uniformly distribute pressure across its surface during the curing or hardening of the adhesive, or the film may be pressed into the surface using a deformable object or surface. After the attachment is complete, the grooves may be coated with reflective or dielectric layers to improve diffraction efficiency.
The Production of Printed Circuit Boards, Photo-Anodised and Screen Printed Instrument Panels.
1981-01-01
Laboratories, Melbourne 12. RELEASE LIMITATIONS (of the document): Approved for Public Release. 12.0. OVERSEAS: N.0.1 I P.R. 1 A I I B I I C I D EI 13...solutions. 5.1 baths Required (N.B. Tanks shoula be of rigid P.V.C.) 1. Amonium persulphate solution 100 gm/L. 2. Sulphuric acid 10% (A.R. GRADE...120 degrees C for at least 10 mins. Etchant 1: 55% weight/volume solution of ferric nitrate used at 49 degrees C. This solution is made by adding
Singh, Ramsharan; Chen, Jin; Miller, Teresa; Bergren, Michael; Mallik, Rangan
2016-12-14
The objective of this study was to compare the stability of recently approved Captisol-stabilized propylene glycol-free melphalan injection (Evomela™) against currently marketed propylene glycol-based melphalan injection. The products were compared as reconstituted solutions in vials as well as admixture solutions prepared from normal saline in infusion bags. Evomela and propylene glycol-based melphalan injection were reconstituted in normal saline and organic custom diluent, respectively, according to their package insert instructions. The reconstituted solutions were diluted in normal saline to obtain drug admixture solutions at specific drug concentrations. Stability of the solutions was studied at room temperature by assay of melphalan and determination of melphalan-related impurities. Results show that based on the increase in total impurities in propylene glycol-based melphalan injection at 0.45 mg/mL, Evomela admixture solutions are about 5, 9, 15 and 29 times more stable at concentrations of 0.45, 1.0, 2.0 and 5.0 mg/mL, respectively. Results confirmed that reconstituted Evomela solution can be stored in the vial for up to 1 h at RT or for up to 24 h at refrigerated temperature (2-8 °C) with no significant degradation. After storage in the vial, it remains stable for an additional 3-29 h after preparation of admixture solution in infusion bags at concentrations of 0.25-5.0 mg/mL, respectively. In addition, Evomela solution in saline, at concentration of 5.0 mg/mL melphalan was bacteriostatic through 72 h storage at 2-8 °C. Formulation of melphalan with Captisol technology significantly improved stability compared to melphalan hydrochloride reconstituted with propylene-glycol based diluents.
Microfluidic model experiments on the injectability of monoclonal antibody solutions
NASA Astrophysics Data System (ADS)
Duchene, Charles; Filipe, Vasco; Nakach, Mostafa; Huille, Sylvain; Lindner, Anke
2017-11-01
Autoinjection devices that allow patients to self-administer medicine are becoming used more frequently; however, this advance comes with an increased need for precision in the injection process. The rare occurrence of protein aggregates in solutions of monoclonal antibodies constitutes a threat to the reliability of such devices. Here we study the flow of protein solutions containing aggregates in microfluidic model systems, mimicking injection devices, to gain fundamental understanding of the catastrophic clogging of constrictions of given size. We form aggregates by mechanically shaking or heating antibody solutions and then inject these solutions into microfluidic channels with varying types of constrictions. Geometrical clogging occurs when aggregates reach the size of the constriction and can in some cases be undone by increasing the applied pressure. We perform systematic experiments varying the relative aggregate size and the flow rate or applied pressure. The mechanical deformation of aggregates during their passage through constrictions is investigated to gain a better understanding of the clogging and unclogging mechanisms.
Behavioral Consequences of Kainic Acid Lesions and Fetal Transplants of the Striatum
1984-06-12
Selected sections were also stained with cresyl violet in order to facilitate the visualization of neuronal cytology and morphology. All sections...tendency to mutism and depression with frequent suicidal ideation (Bruyn, 1973). The Westphal variant of HD, also called the rigid-hypokinetic...1978). In situ injections of kainic acid: A new method for selectively lesioning neuronal cell bodies while sparing axons of passage. Journal of
Childress, Emily M; Kleinstreuer, Clement
2014-03-01
Direct targeting of solid tumors with chemotherapeutic drugs and/or radioactive microspheres can be a treatment option which minimizes side-effects and reduces cost. Briefly, computational analysis generates particle release maps (PRMs) which visually link upstream particle injection regions in the main artery with associated exit branches, some connected to tumors. The overall goal is to compute patient-specific PRMs realistically, accurately, and cost-effectively, which determines the suitable radial placement of a micro-catheter for optimal particle injection. Focusing in this paper on new steps towards realism and accuracy, the impact of fluid-structure interaction on direct drug-targeting is evaluated, using a representative hepatic artery system with liver tumor as a test bed. Specifically, the effect of arterial wall motion was demonstrated by modeling a two-way fluid-structure interaction analysis with Lagrangian particle tracking in the bifurcating arterial system. Clearly, rapid computational evaluation of optimal catheter location for tumor-targeting in a clinical application is very important. Hence, rigid-wall cases were also compared to the flexible scenario to establish whether PRMs generated when based on simplifying assumptions could provide adequate guidance towards ideal catheter placement. It was found that the best rigid (i.e., time-averaged) geometry is the physiological one that occurs during the diastolic targeting interval.
Fuel cell assembly fluid flow plate having conductive fibers and rigidizing material therein
Walsh, Michael M.
2000-01-01
A fluid flow plate is preferably formed with three initial sections, for instance, two layers of conductive (e.g., metal) fibers and a barrier material (e.g., metal foil) which is interposed between the two layers. For example, sintering of these three sections can provide electrical path(s) between outer faces of the two layers. Then, the sintered sections can be, for instance, placed in a mold for forming of flow channel(s) into one or more of the outer faces. Next, rigidizing material (e.g., resin) can be injected into the mold, for example, to fill and/or seal space(s) about a conductive matrix of the electrical path(s). Preferably, abrading of surface(s) of the outer face(s) serves to expose electrical contact(s) to the electrical path(s).
Werk, Tobias; Mahler, Hanns-Christian; Ludwig, Imke Sonja; Luemkemann, Joerg; Huwyler, Joerg; Hafner, Mathias
Dual-chamber syringes were originally designed to separate a solid substance and its diluent. However, they can also be used to separate liquid formulations of two individual drug products, which cannot be co-formulated due to technical or regulatory issues. A liquid/liquid dual-chamber syringe can be designed to achieve homogenization and mixing of both solutions prior to administration, or it can be used to sequentially inject both solutions. While sequential injection can be easily achieved by a dual-chamber syringe with a bypass located at the needle end of the syringe barrel, mixing of the two fluids may provide more challenges. Within this study, the mixing behavior of surrogate solutions in different dual-chamber syringes is assessed. Furthermore, the influence of parameters such as injection angle, injection speed, agitation, and sample viscosity were studied. It was noted that mixing was poor for the commercial dual-chamber syringes (with a bypass designed as a longitudinal ridge) when the two liquids significantly differ in their physical properties (viscosity, density). However, an optimized dual-chamber syringe design with multiple bypass channels resulted in improved mixing of liquids. Dual-chamber syringes were originally designed to separate a solid substance and its diluent. However, they can also be used to separate liquid formulations of two individual drug products. A liquid/liquid dual-chamber syringe can be designed to achieve homogenization and mixing of both solutions prior to administration, or it can be used to sequentially inject both solutions. While sequential injection can be easily achieved by a dual-chamber syringe with a bypass located at the needle end of the syringe barrel, mixing of the two fluids may provide more challenges. Within this study, the mixing behavior of surrogate solutions in different dual-chamber syringes is assessed. Furthermore, the influence of parameters such as injection angle, injection speed, agitation, and sample viscosity were studied. It was noted that mixing was poor for the commercially available dual-chamber syringes when the two liquids significantly differ in viscosity and density. However, an optimized dual-chamber syringe design resulted in improved mixing of liquids. © PDA, Inc. 2017.
Nusinersen injection comes as a solution (liquid) to inject intrathecally (into the fluid-filled space of the spinal canal). Nusinersen injection is given by a doctor in a medical office or clinic. It is usually given as ...
NASA Astrophysics Data System (ADS)
Koumi, Koffi Espoir; Chaise, Thibaut; Nelias, Daniel
2015-07-01
In this paper, the frictionless rolling contact problem between a rigid sphere and a viscoelastic half-space containing one elastic inhomogeneity is solved. The problem is equivalent to the frictionless sliding of a spherical tip over a viscoelastic body. The inhomogeneity may be of spherical or ellipsoidal shape, the later being of any orientation relatively to the contact surface. The model presented here is three dimensional and based on semi-analytical methods. In order to take into account the viscoelastic aspect of the problem, contact equations are discretized in the spatial and temporal dimensions. The frictionless rolling of the sphere, assumed rigid here for the sake of simplicity, is taken into account by translating the subsurface viscoelastic fields related to the contact problem. Eshelby's formalism is applied at each step of the temporal discretization to account for the effect of the inhomogeneity on the contact pressure distribution, subsurface stresses, rolling friction and the resulting torque. A Conjugate Gradient Method and the Fast Fourier Transforms are used to reduce the computation cost. The model is validated by a finite element model of a rigid sphere rolling upon a homogeneous vciscoelastic half-space, as well as through comparison with reference solutions from the literature. A parametric analysis of the effect of elastic properties and geometrical features of the inhomogeneity is performed. Transient and steady-state solutions are obtained. Numerical results about the contact pressure distribution, the deformed surface geometry, the apparent friction coefficient as well as subsurface stresses are presented, with or without heterogeneous inclusion.
Paulis, Gianni; Barletta, Davide; Turchi, Paolo; Vitarelli, Antonio; Dachille, Giuseppe; Fabiani, Andrea; Gennaro, Romano
2016-01-01
Peyronie’s disease (PD) is a chronic disorder involving the tunica albuginea surrounding the corpora cavernosa of the penis. A conservative treatment is indicated in the first stage of disease. The aim of this study was to assess the therapeutic impact and possible side effects of treatment with pentoxifylline (PTX) in combination with other antioxidants in 307 patients with early-stage PD. Patients were subdivided into three groups: A, B, and C. Both groups, A and B, comprising of 206 patients, underwent treatment, whereas Group C was the control group (n=101). Treatment lasted 6 months and included the following: Group A: PTX 400 mg twice a day + propolis 600 mg/d + blueberry 160 mg/d + vitamin E 600 mg/d + diclofenac 4% gel twice/a day + PTX 100 mg via perilesional penile injection/every other week (12 injections in all); Group B: the same treatment as Group A except for the penile PTX injections. After the 6-month treatment course, we obtained the following results: actual mean decrease in plaque volume −46.9% and −24.8% in Group A and B, respectively (P<0.0001); mean curvature reduction −10.1° and −4.8°, respectively (P,0.0001); resolution of pain in 67.6% and 67.2% of cases, respectively (P=0.961); recovery of normal penile rigidity in 56.09% and 23.5% of cases, respectively (P=0.005). After 6 months, progression of disease was observed in all patients belonging to Group C: plaque volume +123.3%; curvature +15.7°; no recovery of penile rigidity. The statistically significant results of our study show that multimodal treatment with PTX in association with other antioxidants and topical diclofenac is efficacious in treating early-stage PD. Furthermore, treatment proved to be more effective when PTX was administered both orally and by penile injection. No serious adverse effects occurred. PMID:26770906
[Formation of oxalate in oxaliplatin injection diluted with infusion solutions].
Eto, Seiji; Yamamoto, Kie; Shimazu, Kounosuke; Sugiura, Toshimune; Baba, Kaori; Sato, Ayaka; Goromaru, Takeshi; Hagiwara, Yoshiaki; Hara, Keiko; Shinohara, Yoshitake; Takahashi, Kojiro
2014-01-01
Oxaliplatin use can cause acute peripheral neuropathy characterized by sensory paresthesias, which are markedly exacerbated by exposure to cold temperatures, and is a dose-limiting factor in the treatment of colorectal cancer.Oxalate is eliminated in a series of nonenzymatic conversions of oxaliplatin in infusion solutions or biological fluids.Elimination of oxalate from oxaliplatin has been suggested as one of the reasons for the development of acute neuropathy.In this study, we developed a high-performance liquid chromatography(HPLC)-based method to detect oxalate formation, and investigated the time dependent formation of oxalate in oxaliplatin diluted with infusion solutions.The results obtained showed that the amount of oxalate in the solution corresponded to 1.6% of oxaliplatin 8 h after oxaliplatin dilution with a 5% glucose solution. On the other hand, oxalate formation from oxaliplatin diluted with a saline solution was ten-fold higher than that from oxaliplatin diluted with the 5% glucose solution.Most patients who were intravenously injected with oxaliplatin experienced venous pain.As a preventive measure against venous pain, dexamethasone was added to the oxaliplatin injection.We measured the amount of oxalate formed in the dexamethasone-containing oxaliplatin injection diluted with a 5% glucose solution.The amount of oxalate formed when dexamethasone was added did not differ significantly from that formed when dexamethasone was not added.Thus, there are no clinical problems associated with the stability of oxaliplatin solutions.
Emotional rigidity negatively impacts remission from anxiety and recovery of well-being.
Wiltgen, Anika; Shepard, Christopher; Smith, Ryan; Fowler, J Christopher
2018-08-15
Emotional rigidity is described in clinical literature as a significant barrier to recovery; however, few there are few empirical measures of the construct. The current study had two aims: Study 1 aimed to identify latent factors that may bear on the construct of emotional rigidity while Study 2 assessed the potential impact of the latent factor(s) on anxiety remission rates and well-being. This study utilized data from 2472 adult inpatients (1176 females and 1296 males) with severe psychopathology. Study 1 utilized exploratory factor analysis (EFA) and confirmatory factor analysis (CFA) to identify latent factors of emotional rigidity. Study 2 utilized hierarchical logistic regression analyses to assess the relationships among emotional rigidity factors and anxiety remission and well-being recovery at discharge. Study 1 yielded a two-factor solution identified in EFA was confirmed with CFA. Factor 1 consisted of neuroticism, experiential avoidance, non-acceptance of emotions, impaired goal-directed behavior, impulse control difficulties and limited access to emotion regulation strategies when experiencing negative emotions. Factor 2 consisted of lack of emotional awareness and lack of emotional clarity when experiencing negative emotions. Results of Study 2 indicated higher scores on Factor 1 was associated with lower remission rates from anxiety and poorer well-being upon discharge. Factor 2 was not predictive of outcome. Emotional rigidity appears to be a latent construct that negatively impacts remission rates from anxiety. Limitations of the present study include its retrospective design, and inefficient methods of assessing emotional rigidity. Copyright © 2018. Published by Elsevier B.V.
Kaiser, Jeanette; Krämer, Irene
2012-06-01
The aim of this study was to investigate the physicochemical stability of clofarabine (CAFdA) injection concentrate and ready-to-use CAFdA infusion solutions over a prolonged period of 28 days. To determine the stability of CAFdA infusion solutions, the injection concentrate (Evoltra®, 1 mg/mL, Genzyme) was diluted either with 0.9% sodium chloride or 5% glucose infusion solution. The resulting concentrations of 0.2 mg/mL or 0.6 mg/mL, respectively, were chosen to represent the lower and upper limit of the ordinary concentration range. Test solutions were stored under refrigeration (2-8°C) or at room temperature either light protected or exposed to light. CAFdA concentrations and pH values were determined at different time intervals throughout a 28-day storage period. Compatibility of diluted CAFdA infusion solutions (0.1-0.4 mg/mL) with different container materials (polyvinyl chloride (PVC), glass, and polypropylene/polyethylene (PP/PE)) was tested over a 48-h storage period. CAFdA concentrations were measured by a stability-indicating reversed phase high-performance liquid chromatography (HPLC) assay with ultraviolet detection. CAFdA injection concentrate and CAFdA infusion solutions remained physicochemically stable (>90% CAFdA) for 4 weeks. Results are independent of storage conditions, drug concentrations (0.2, 0.6, and 1.0 mg/mL) and diluents (0.9% sodium chloride, 5% glucose infusion solution). Adsorption of CAFdA to container material can be excluded. CAFdA injection concentrate and diluted infusion solutions in commonly used vehicles are stable for at least 28 days either refrigerated or at room temperature. Physicochemical stability favors pharmacy-based centralized preparation. Due to microbiological reasons, strict aseptic handling and storage of the products under refrigeration is recommended.
Teriparatide (rDNA origin) Injection
... teriparatide injection yourself the first time, read the User Manual that comes with it. Ask your doctor or ... injecting the medication how to inject it. The User Manual includes solutions to problems you may have when ...
NASA Astrophysics Data System (ADS)
Borowiak, Małgorzata; Grobelna, Beata; Synak, Anna; Bojarski, Piotr; Kubicki, Aleksander A.
2013-11-01
Time-resolved emission spectra of 4-dimethylamino-4‧-cyano-stilbene (DMACS) and 3,5,4‧-trihydroxy-stilbene (resveratrol, RSV) in propylene glycol and in rigid silica xerogel matrix at 23 °C were studied. For the polar molecule DMACS in propylene glycol, a 66 nm shift of maximum wavelength of emission spectra was observed within 1 ns after excitation, and most of the shift occurred during the first 200 ps. For resveratrol in propylene glycol no such a shift was observed. The rigid silica environment eliminates some deactivation pathways and stabilizes spectroscopic properties of both molecules. Spectral properties of nonpolar and high dipole moment molecules in viscous liquids and rigid environments are compared. Results are explained on the basis of intramolecular processes and solute-solvent relaxation, as well.
Water-assisted growth of graphene on carbon nanotubes by the chemical vapor deposition method.
Feng, Jian-Min; Dai, Ye-Jing
2013-05-21
Combining carbon nanotubes (CNTs) with graphene has been proved to be a feasible method for improving the performance of graphene for some practical applications. This paper reports a water-assisted route to grow graphene on CNTs from ferrocene and thiophene dissolved in ethanol by the chemical vapor deposition method in an argon flow. A double injection technique was used to separately inject ethanol solution and water for the preparation of graphene/CNTs. First, CNTs were prepared from ethanol solution and water. The injection of ethanol solution was suspended and water alone was injected into the reactor to etch the CNTs. Thereafter, ethanol solution was injected along with water, which is the key factor in obtaining graphene/CNTs. Transmission electron microscopy, scanning electron microscopy, X-ray diffraction, and Raman scattering analyses confirmed that the products were the hybrid materials of graphene/CNTs. X-ray photo-electron spectroscopy analysis showed the presence of oxygen rich functional groups on the surface of the graphene/CNTs. Given the activity of the graphene/CNT surface, CdS quantum dots adhered onto it uniformly through simple mechanical mixing.
Prediction of sound absorption in rigid porous media with the lattice Boltzmann method
NASA Astrophysics Data System (ADS)
da Silva, Andrey Ricardo; Mareze, Paulo; Brandão, Eric
2016-02-01
In this work, sound absorption phenomena associated with the viscous shear stress within rigid porous media is investigated with a simple isothermal lattice Boltzmann BGK model. Simulations are conducted for different macroscopic material properties such as sample thickness and porosity and the results are compared with the exact analytical solution for materials with slit-like structure in terms of acoustic impedance and sound absorption coefficient. The numerical results agree very well with the exact solution, particularly for the sound absorption coefficient. The small deviations found in the low frequency limit for the real part of the acoustic impedance are attributed to the ratio between the thicknesses of the slit and the viscous boundary layer. The results suggest that the lattice Boltzmann method can be a very compelling numerical tool for simulating viscous sound absorption phenomena in the time domain, particularly due to its computational simplicity when compared to traditional continuum based techniques.
Rigidity and pH dependent Morphology of Beta-Lactoglobulin Spherulites
NASA Astrophysics Data System (ADS)
Gayetsky, Lisa; Armstead, Douglas
2008-03-01
Beta-Lactoglobulin is a milk protein that will denature in acidic solution (less than 2.0 pH) and if heated for extended periods (greater than 18 hours) it will form radial structures called Spherulites. Spherulites, along with the amyloid fibrils that compose them, are of practical importance because they form in the human body and cause the amyloidosis diseases. Different amyloidosis are caused by different types of denatured proteins occurring in different parts of the body. Since it is believed that Spherulite formation is a generic protein characteristic, Beta-Lactoglobulin is a legitimate and easy to use protein to study these structures. In this study we are quantifying the shape of Beta-Lactoglobulin Spherulites to determine if the pH of the protein solution has an impact on the morphology due to side chain interactions or other causes. We are also testing the rigidity of these structures to determine the relevance of small shape changes.
A high stability and repeatability electrochemical scanning tunneling microscope.
Xia, Zhigang; Wang, Jihao; Hou, Yubin; Lu, Qingyou
2014-12-01
We present a home built electrochemical scanning tunneling microscope (ECSTM) with very high stability and repeatability. Its coarse approach is driven by a closely stacked piezo motor of GeckoDrive type with four rigid clamping points, which enhances the rigidity, compactness, and stability greatly. It can give high clarity atomic resolution images without sound and vibration isolations. Its drifting rates in XY and Z directions in solution are as low as 84 pm/min and 59 pm/min, respectively. In addition, repeatable coarse approaches in solution within 2 mm travel distance show a lateral deviation less than 50 nm. The gas environment can be well controlled to lower the evaporation rate of the cell, thus reducing the contamination and elongating the measurement time. Atomically resolved SO4(2-) image on Au (111) work electrode is demonstrated to show the performance of the ECSTM.
Verification of a Constraint Force Equation Methodology for Modeling Multi-Body Stage Separation
NASA Technical Reports Server (NTRS)
Tartabini, Paul V.; Roithmayr, Carlos; Toniolo, Matthew D.; Karlgaard, Christopher; Pamadi, Bandu N.
2008-01-01
This paper discusses the verification of the Constraint Force Equation (CFE) methodology and its implementation in the Program to Optimize Simulated Trajectories II (POST2) for multibody separation problems using three specially designed test cases. The first test case involves two rigid bodies connected by a fixed joint; the second case involves two rigid bodies connected with a universal joint; and the third test case is that of Mach 7 separation of the Hyper-X vehicle. For the first two cases, the POST2/CFE solutions compared well with those obtained using industry standard benchmark codes, namely AUTOLEV and ADAMS. For the Hyper-X case, the POST2/CFE solutions were in reasonable agreement with the flight test data. The CFE implementation in POST2 facilitates the analysis and simulation of stage separation as an integral part of POST2 for seamless end-to-end simulations of launch vehicle trajectories.
NASA Astrophysics Data System (ADS)
Bukalov, Sergey S.; Aysin, Rinat R.; Leites, Larissa A.; Kurykin, Mikhail A.; Khrustalev, Victor N.
2015-10-01
Calculation of potential energy surface (PES) of isolated molecule of copper(II) diiminate Cu[CF3С(NH)C(F)C(NH)CF3]2 (1) resulted a double-well curve with the minima corresponding to equivalent screwed conformations. The low barrier leads to molecular non-rigidity which seems to be the reason of conformational polymorphism in crystals, reported in [1]. For one of newly found polymorphs, the X-ray structure was determined. The differences in the Raman and UV-vis spectra between differently colored species and their solutions were revealed, they are determined by different geometries of Cu(II) coordination polyhedron and different systems of intermolecular interactions in crystals. Transformations of the polymorphs under thermal, mechanical and photo exposures were studied.
NASA Astrophysics Data System (ADS)
Bilyi, Olexander I.; Getman, Vasyl B.; Konyev, Fedir A.; Sapunkov, Olexander; Sapunkov, Pavlo G.
2001-06-01
The devices for monitoring of parameters of efficiency of water solutions filtration, which are based on the analysis of scattered light by microparticles are considered in this article. The efficiency of using of devices in pharmaceutics in technological processes of manufacturing medical injection solutions is shown. The examples of monitoring of contents of bacterial cultures Pseudomonas aeruginosa, Escherichia coli, and Micrococcus luteus in water solutions of glucose are indicated.
Zendehdel, M; Sardari, F; Hassanpour, S; Rahnema, M; Adeli, A; Ghashghayi, E
2017-06-01
1. Serotoninergic and adrenergic systems play crucial roles in feed intake regulation in avians but there is no report on possible interactions among them. So, in this study, 5 experiments were designed to evaluate the interaction of central serotonergic and adrenergic systems on food intake regulation in 3 h food deprived (FD 3 ) neonatal layer-type chickens. 2. In Experiment 1, chickens received intracerebroventricular (ICV) injection of control solution, serotonin (56.74 nmol), prazosin (α 1 receptor antagonist, 10 nmol) and co-injection of serotonin plus prazosin. In Experiment 2, control solution, serotonin (56.74 nmol), yohimbine (α 2 receptor antagonist, 13 nmol) and co-injection of serotonin plus yohimbine were used. In Experiment 3, the birds received control solution, serotonin (56.74 nmol), metoprolol (β 1 receptor antagonist, 24 nmol) and co-injection of serotonin plus metoprolol. In Experiment 4, injections were control solution, serotonin (56.74 nmol), ICI 118.551 (β 2 receptor antagonist, 5 nmol) and serotonin plus ICI 118.551. In Experiment 5, control solution, serotonin (56.74 nmol), SR59230R (β 3 receptor antagonist, 20 nmol) and co-administration of serotonin and SR59230R were injected. In all experiments the cumulative food intake was measured until 120 min post injection. 3. The results showed that ICV injection of serotonin alone decreased food intake in chickens. A combined injection of serotonin plus ICI 118.551 significantly attenuated serotonin-induced hypophagia. Also, co-administration of serotonin and yohimbine significantly amplified the hypophagic effect of serotonin. However, prazosin, metoprolol and SR59230R had no effect on serotonin-induced hypophagia in chickens. 4. These results suggest that serotonin-induced feeding behaviour is probably mediated via α 2 and β 2 adrenergic receptors in neonatal layer-type chicken.
He, Ying; Zhang, Yangyang; Han, Juanjuan; Zhu, Ping; Zhang, Yuxin; Zheng, Qinxiang; Li, Xia; Zhao, Chen; Pang, Jijing
2015-01-01
Purpose To introduce a practical method of subretinal injection in mice and evaluate injection-induced retinal detachment (RD) and damage using a dynamic imaging system, electrophysiology, and histology. Methods After full dilation of a 2-month-old C57BL/6J mouse pupil, the cornea near the limbus was punctured with a 30 ½-gague disposable beveled needle. A 33 ½-gauge blunt needle was inserted through the corneal perforation into the anterior chamber, avoiding the lens before going deeper into the vitreous cavity, and penetrating the inner retina to reach the subretinal space. The mice were divided into four groups: in group 1, about 80–100% of the retina was filled with subretinally injected solution; in group 2, approximately 50–70% of the retina was filled with injected solution; in group 3, the procedures were stopped before solution injection; and non-injected eyes were used as the negative control in group 4. An optical coherence tomography (OCT) imaging system was used to monitor retinal reattachment during the first three days following the injections. Histological and functional changes were examined by light microscopy and electroretinography (ERG) at five weeks post-injection. Results After a short-term training, a 70% success rate with 50% or more coverage (i.e., retinal blebs occupied 50% or more retinal area and filled with the injected solution) with minimal injection-related damages can be achieved. Bleb formation was associated with retinal detachment (RD) between the neuroretina and the retinal pigment epithelium (RPE) layer. Partial RD could be observed at post-injection day 1, and by day 2 most of the retina had reattached. At 5 weeks post-injection, compared to uninjected control group 4, the b-wave amplitudes of ERG decreased 22% in group 1, 16% in group 2, and 7% in group 3; the b-wave amplitudes were statistically different between the uninjected group and the groups with either 50–70% or 80–100% coverage. The subretinal injection-induced RD reattached and became stable at five weeks post-injection, although some photoreceptor damage could still be observed in and around the injection sites, especially in 80–100% coverage group. Conclusions Trans-corneal subretinal injection is effective and practical, although subretinal injection-related damages can cause some morphological and functional loss. PMID:26317758
Revisitation of the dipole tracer test for heterogeneous porous formations
NASA Astrophysics Data System (ADS)
Zech, Alraune; D'Angelo, Claudia; Attinger, Sabine; Fiori, Aldo
2018-05-01
In this paper, a new analytical solution for interpreting dipole tests in heterogeneous media is derived by associating the shape of the tracer breakthrough curve with the log-conductivity variance. It is presented how the solution can be used for interpretation of dipole field test in view of geostatistical aquifer characterization on three illustrative examples. The analytical solution for the tracer breakthrough curve at the pumping well in a dipole tracer test is developed by considering a perfectly stratified formation. The analysis is carried out making use of the travel time of a generic solute particle, from the injection to the pumping well. Injection conditions are adapted to different possible field setting. Solutions are presented for resident and flux proportional injection mode as well as for an instantaneous pulse of solute and continuous solute injections. The analytical form of the solution allows a detailed investigation on the impact of heterogeneity, the tracer input conditions and ergodicity conditions at the well. The impact of heterogeneity manifests in a significant spreading of solute particles that increases the natural tendency to spreading induced by the dipole setup. Furthermore, with increasing heterogeneity the number of layers needed to reach ergodic conditions become larger. Thus, dipole test in highly heterogeneous aquifers might take place under non-ergodic conditions giving that the log-conductivity variance is underestimated. The method is a promising geostatistical analyzing tool being the first analytical solution for dipole tracer test analysis taking heterogeneity of hydraulic conductivity into account.
Gérard, Maxime; Michaud, François; Bigot, Alexandre; Tang, An; Soulez, Gilles; Kadoury, Samuel
2017-06-01
Modulating the chemotherapy injection rate with regard to blood flow velocities in the tumor-feeding arteries during intra-arterial therapies may help improve liver tumor targeting while decreasing systemic exposure. These velocities can be obtained noninvasively using Doppler ultrasound (US). However, small vessels situated in the liver are difficult to identify and follow in US. We propose a multimodal fusion approach that non-rigidly registers a 3D geometric mesh model of the hepatic arteries obtained from preoperative MR angiography (MRA) acquisitions with intra-operative 3D US imaging. The proposed fusion tool integrates 3 imaging modalities: an arterial MRA, a portal phase MRA and an intra-operative 3D US. Preoperatively, the arterial phase MRA is used to generate a 3D model of the hepatic arteries, which is then non-rigidly co-registered with the portal phase MRA. Once the intra-operative 3D US is acquired, we register it with the portal MRA using a vessel-based rigid initialization followed by a non-rigid registration using an image-based metric based on linear correlation of linear combination. Using the combined non-rigid transformation matrices, the 3D mesh model is fused with the 3D US. 3D US and multi-phase MRA images acquired from 10 porcine models were used to test the performance of the proposed fusion tool. Unimodal registration of the MRA phases yielded a target registration error (TRE) of [Formula: see text] mm. Initial rigid alignment of the portal MRA and 3D US yielded a mean TRE of [Formula: see text] mm, which was significantly reduced to [Formula: see text] mm ([Formula: see text]) after affine image-based registration. The following deformable registration step allowed for further decrease of the mean TRE to [Formula: see text] mm. The proposed tool could facilitate visualization and localization of these vessels when using 3D US intra-operatively for either intravascular or percutaneous interventions to avoid vessel perforation.
Trajectory Correction and Locomotion Analysis of a Hexapod Walking Robot with Semi-Round Rigid Feet
Zhu, Yaguang; Jin, Bo; Wu, Yongsheng; Guo, Tong; Zhao, Xiangmo
2016-01-01
Aimed at solving the misplaced body trajectory problem caused by the rolling of semi-round rigid feet when a robot is walking, a legged kinematic trajectory correction methodology based on the Least Squares Support Vector Machine (LS-SVM) is proposed. The concept of ideal foothold is put forward for the three-dimensional kinematic model modification of a robot leg, and the deviation value between the ideal foothold and real foothold is analyzed. The forward/inverse kinematic solutions between the ideal foothold and joint angular vectors are formulated and the problem of direct/inverse kinematic nonlinear mapping is solved by using the LS-SVM. Compared with the previous approximation method, this correction methodology has better accuracy and faster calculation speed with regards to inverse kinematics solutions. Experiments on a leg platform and a hexapod walking robot are conducted with multi-sensors for the analysis of foot tip trajectory, base joint vibration, contact force impact, direction deviation, and power consumption, respectively. The comparative analysis shows that the trajectory correction methodology can effectively correct the joint trajectory, thus eliminating the contact force influence of semi-round rigid feet, significantly improving the locomotion of the walking robot and reducing the total power consumption of the system. PMID:27589766
Coffee shops and clinics: the give and take of doing HIV/AIDS research with injecting drug users.
Marsh, A; Loxley, W
1992-06-01
We discuss recruiting and interviewing injecting drug users and using research as health promotion in the context of collecting information related to human immunodeficiency virus (HIV) or acquired immune deficiency syndrome (AIDS) from a convenience sample of 200 injecting drug users, half in treatment and half not, in 1989 and 1990 in Perth, Western Australia. A variety of recruiting methods were used including advertising, referral by agency staff, 'snowballing' and approaches to personal contacts and others known to inject by the interviewer. Snowballing and personal contacts were the most successful means of recruiting those not in treatment, while advertising was comparatively unsuccessful with this group because of the importance of establishing the credibility of the study and the interviewer among injecting drug users before they will volunteer to be involved. The promotion of behavioural risk reduction among respondents during the interview is detailed. We argue that the traditionally rigid separation between research and intervention is inappropriate in the HIV/AIDS context. When lives are potentially at stake, any contact with injecting drug users, especially those not in treatment (where may receive HIV/AIDS education), must be used as an HIV/AIDS prevention opportunity, and the interview is an ideal opportunity. The employment of research as community intervention is also discussed.
NASA Astrophysics Data System (ADS)
Silveira, Ana J.; Abreu, Charlles R. A.
2017-09-01
Sets of atoms collectively behaving as rigid bodies are often used in molecular dynamics to model entire molecules or parts thereof. This is a coarse-graining strategy that eliminates degrees of freedom and supposedly admits larger time steps without abandoning the atomistic character of a model. In this paper, we rely on a particular factorization of the rotation matrix to simplify the mechanical formulation of systems containing rigid bodies. We then propose a new derivation for the exact solution of torque-free rotations, which are employed as part of a symplectic numerical integration scheme for rigid-body dynamics. We also review methods for calculating pressure in systems of rigid bodies with pairwise-additive potentials and periodic boundary conditions. Finally, simulations of liquid phases, with special focus on water, are employed to analyze the numerical aspects of the proposed methodology. Our results show that energy drift is avoided for time step sizes up to 5 fs, but only if a proper smoothing is applied to the interatomic potentials. Despite this, the effects of discretization errors are relevant, even for smaller time steps. These errors induce, for instance, a systematic failure of the expected equipartition of kinetic energy between translational and rotational degrees of freedom.
NASA Astrophysics Data System (ADS)
Prasanna Kumar, S. S.; Patnaik, B. S. V.; Ramamurthi, K.
2018-04-01
The mitigation of blast waves propagating in air and interacting with rigid barriers and obstacles is numerically investigated using the mesh-free smoothed particle hydrodynamics method. A novel virtual boundary particle procedure with a skewed gradient wall boundary treatment is applied at the interfaces between air and rigid bodies. This procedure is validated with closed-form solutions for strong and weak shock reflection from rigid surfaces, supersonic flows over a wedge, formation of reflected, transverse, and Mach stem shocks, and also earlier experiments on interaction of a blast wave with concrete blocks. The mitigation of the overpressure and impulse transmitted to the protected structure due to an array of rigid obstacles of different shapes placed in the path of the blast wave is thereafter determined and discussed in the context of the existing experimental and numerical studies. It is shown that blockages having the shape of a right facing triangle or square placed in tandem or staggered provide better mitigation. The influence of the distance between the blockage array and protected structure is assessed, and the incorporation of a gap in the blockages is shown to improve the mitigation. The mechanisms responsible for the attenuation of air blast are identified through the simulations.
A 2D nonlinear multiring model for blood flow in large elastic arteries
NASA Astrophysics Data System (ADS)
Ghigo, Arthur R.; Fullana, Jose-Maria; Lagrée, Pierre-Yves
2017-12-01
In this paper, we propose a two-dimensional nonlinear ;multiring; model to compute blood flow in axisymmetric elastic arteries. This model is designed to overcome the numerical difficulties of three-dimensional fluid-structure interaction simulations of blood flow without using the over-simplifications necessary to obtain one-dimensional blood flow models. This multiring model is derived by integrating over concentric rings of fluid the simplified long-wave Navier-Stokes equations coupled to an elastic model of the arterial wall. The resulting system of balance laws provides a unified framework in which both the motion of the fluid and the displacement of the wall are dealt with simultaneously. The mathematical structure of the multiring model allows us to use a finite volume method that guarantees the conservation of mass and the positivity of the numerical solution and can deal with nonlinear flows and large deformations of the arterial wall. We show that the finite volume numerical solution of the multiring model provides at a reasonable computational cost an asymptotically valid description of blood flow velocity profiles and other averaged quantities (wall shear stress, flow rate, ...) in large elastic and quasi-rigid arteries. In particular, we validate the multiring model against well-known solutions such as the Womersley or the Poiseuille solutions as well as against steady boundary layer solutions in quasi-rigid constricted and expanded tubes.
Compatibility of azathioprine sodium with intravenous fluids.
Johnson, C A; Porter, W A
1981-06-01
The effects of storage containers, diluent, temperature, and illumination on the stability and compatibility of azathioprine sodium were studied. Reconstituted solutions were stored in the manufacturer's vial and a plastic syringe. Diluted solutions were stored in mini-bags mixed with standard intravenous solutions (5% dextrose injection, 0.9% sodium chloride injection, and 0.45% sodium chloride injection). Samples were stored at 4 degrees C in the dark and at 23 degrees C under constant illumination. Samples containing an internal standard, 6-methylmercaptopurine, were assayed by ion exchange chromatography at 0, 8, and 16 days. Accelerated decomposition studies at 70 degrees C also were performed to determine the chromatographic method's capability for separating azathioprine from its breakdown products. No solutions or admixtures differed significantly (p greater than 0.13) from initial concentrations after 16 days at 23 degrees C under constant illumination. Mixture with 5% dextrose injection caused precipitation by day 16. Azathioprine sodium reconstituted and stored in the manufacturer's vial or a plastic syringe at 4 degrees C formed a precipitate by day 4. Sterility is the limiting factor determining suitability for use of azathioprine solutions kept less than four days.
NASA Astrophysics Data System (ADS)
Tarumi, Moto; Nakai, Hiromi
2018-05-01
This letter proposes an approximate treatment of the harmonic solvation model (HSM) assuming the solute to be a rigid body (RB-HSM). The HSM method can appropriately estimate the Gibbs free energy for condensed phases even where an ideal gas model used by standard quantum chemical programs fails. The RB-HSM method eliminates calculations for intra-molecular vibrations in order to reduce the computational costs. Numerical assessments indicated that the RB-HSM method can evaluate entropies and internal energies with the same accuracy as the HSM method but with lower calculation costs.
NASA Technical Reports Server (NTRS)
Elishakoff, Isaac; Marcus, S.; Starnes, J. H., JR.
1998-01-01
In this paper we present a closed-form solution for vibrational imperfection sensitivity the effect of small imperfections on the vibrational frequencies of perturbed motion around the static equilibrium state of Augusti's model Structure (a rigid link, pinned at one end to a rigid foundation and supported at the other by a linear extensional spring that retains its horizontality, as the system deflects). We also treat a modified version of that model with attendant slightly different dynamics. It is demonstrated that the vibrational frequencies decreases as the initial imperfections increase.
New Whole-House Solutions Case Study: Tindall Homes, Columbus, New Jersey
DOE Office of Scientific and Technical Information (OSTI.GOV)
none,
The builder worked with IBACOS to build 20 HERS-58 homes with R-49 mixed attic insulation, poly-iso foam in advanced framed walls, precast concrete basement walls with rigid foam, tight airsealing, and HRV
Tarcan, Tufan; Akbal, Cem; Sekerci, Cağri A; Top, Tuncay; Simşek, Ferruh
2014-04-01
This was a prospective single-arm study to assess the efficacy and safety of intradetrusor injections of onabotulinum toxin-A in children with urinary incontinence associated with neurogenic detrusor overactivity due to myelomeningocele. All patients had failed the first-line treatment of a combination of oral antimuscarinics and intermittent catheterization. The study group consisted of 31 children with myelomeningocele with a mean age of 7.95 years (range, 5-3 years) who were followed up for a mean of 29 weeks. The amount of onabotulinum toxin A injected was 10 U/kg with a maximal dose of 300 U. There were 20 to 30 injection sites with rigid cystoscopic guidance under general anesthesia. Thirty of 31 patients reported dryness between intermittent catheterization intervals. The mean reduction in maximum detrusor pressure and the mean increase in maximum cystometric capacity from baseline were 53% and 51.5%, respectively, 6 weeks after injection. We found a 324% increase in mean bladder compliance and a 57% increase in mean intermittent catheterization volumes. The mean duration of efficacy was 28 weeks with a single injection and 36 weeks for repeated injections (minimum, 16 weeks; maximum, 52 weeks). The mean time interval between repeated onabotulinum toxin-A injections was 7 months (maximum, 13 months). Intradetrusor injections of onabotulinum toxin-A were well tolerated. Onabotulinum toxin-A injections into the bladder wall provide a significant symptomatic and urodynamic improvement in children with neurogenic detrusor overactivity due to myelomeningocele who are on intermittent catheterization. The treatment seems to be safe and very well tolerated.
Karlage, Kelly; Earhart, Zachary; Green-Boesen, Kelly; Myrdal, Paul B
2011-08-15
The stability of midazolam hydrochloride injection 1-mg/mL solutions in polyvinyl chloride (PVC) and polyolefin bags under varying conditions was evaluated. Triplicate solutions of midazolam hydrochloride 1-mg/mL were prepared in polyolefin and PVC i.v. bags by diluting midazolam hydrochloride injection 5 mg/mL with 5% dextrose injection. Bags were then stored under refrigeration (3-4 °C), exposed to light at room temperature (20-25 °C), or protected from light in amber bags at room temperature. Samples were taken immediately after preparation (day 0) and on days 1, 2, 3, 6, 13, 20, and 27 for analysis with a stability-indicating high-performance liquid chromatography assay in order to determine solution concentration. Stability was defined as retention of at least 90% of the initial drug concentration. The pH of each solution was also measured weekly. Sterility of the i.v. bags was determined at the end of the study by microbiological testing with culture in growth media. Differences in concentrations under the various storage conditions and bags used were analyzed using analysis of variance. All solutions retained over 98% of the initial midazolam hydrochloride concentration, with no statistically significant (p ≥ 0.05) change in concentration over the four-week period. Stability was not affected by temperature, exposure to light, or bag type. The pH of all solutions remained between 3.2 and 3.4 throughout the study. Sterility after 28 days was retained. Midazolam hydrochloride 1-mg/mL solutions diluted in 5% dextrose injection remained stable over 27 days in both polyolefin and PVC i.v. bags, regardless of storage condition.
Gursoy, U K; Bostanci, V; Kosger, H H
2006-02-01
A case is reported in which sodium hypochlorite (NaOCl) was inadvertently injected into the palatal mucosa instead of local anaesthetic solution. An adult male was referred to the University clinic 15 days after an inadvertent NaOCl injection into the palatal mucosa. Soft tissue necrosis was evident, without obvious bony involvement. Tissues healed without scarring within 30 days. No surgical intervention was required. NaOCl is highly irritant when extruded into vital tissues.--Dentists should be careful to avoid the misuse of NaOCl, and should check the nature of any agent before injecting it into patients.--NaOCl should not be dispensed in a way that could allow it to be mistaken for local anaesthetic solutions.--The well-perfused tissues of the oral cavity have considerable healing ability.
Mouttalib, Sofia; Khan, Shahid; Castel-Lacanal, Evelyne; Guillotreau, Julien; De Boissezon, Xavier; Malavaud, Bernard; Marque, Philippe; Rischmann, Pascal; Gamé, Xavier
2010-12-01
To determine if antibiotic prophylaxis is required for intradetrusor botulinum toxin A (BoNT-A) injections. This was a prospective non-randomized study. Inclusion criteria were adult patients with neurogenic detrusor overactivity who failed anticholinergic-based first-line treatment and had sterile urine culture 7 days before injections, a negative dipstick test on the day of the injections, and were performing clean intermittent self-catheterization. Injections were performed using a rigid cystoscope, under local anaesthetic. Patients received BoNT-A as either Botox® (Allergan Inc., Irvine, CA, USA) 300 U in 30 sites or Dysport® (Ipsen Ltd, Ipsen, Paris, France) 750 U in 20 sites. Urine culture was done 6 days and 6 weeks after the injections. If urinary tract infection (UTI) was suspected, a physician performed a complete physical examination. The primary outcome criterion was the occurrence of UTI during the first week after injections. In all, 42 patients (22 women, 20 men) with a mean (sd) age 45.3 (16.4) years were included. A symptomatic UTI occurred during the first week after the injections in three patients (7.1%). The urinary colonization rate was 31% and 26% at 6 days and 6 weeks after injection, respectively. The most common bacterium was Escherichia coli (62.5%). There were no differences between 20 and 30 injection sites or between the sexes. The rate of UTI after intradetrusor injections of BoNT-A was 7.1%. The most frequent bacterium involved was Escherichia coli. These results indicate that antibiotic prophylaxis for intradetrusor BoNT-A injections seems necessary. © 2010 THE AUTHORS. JOURNAL COMPILATION © 2010 BJU INTERNATIONAL.
Capillary-Driven Solute Transport and Precipitation in Porous Media during Dry-Out
NASA Astrophysics Data System (ADS)
Ott, Holger; Andrew, Matthew; Blunt, Martin; Snippe, Jeroen
2014-05-01
The injection of dry or under-saturated gases or supercritical (SC) fluids into water bearing formations might lead to a formation dry-out in the vicinity of the injection well. The dry-out is caused by the evaporation/dissolution of formation water into the injected fluid and the subsequent transport of dissolved water in the injected fluid away from the injection well. Dry-out results in precipitation from solutes of the formation brine and consequently leads to a reduction of the rock's pore space (porosity) and eventually to a reduction of permeability near the injection well, or even to the loss of injectivity. Recently evidence has been found that the complexity of the pore space and the respective capillary driven solute transport plays a key role. While no effective-permeability (Keff) reduction was observed in a single-porosity sandstone, multi porosity carbonate rocks responded to precipitation with a strong reduction of Keff. The reason for the different response of Keff to salt precipitation is suspected to be in the exact location of the precipitate (solid salt) in the pore space. In this study, we investigate dry-out and salt precipitation due to supercritical CO2 injection in single and multi-porosity systems under near well-bore conditions. We image fluid saturation changes by means of μCT scanning during desaturation. We are able to observe capillary driven transport of the brine phase and the respective transport of solutes on the rock's pore scale. Finally we have access to the precipitated solid-salt phase and their distribution. The results can proof the thought models behind permeability porosity relationships K(φ) for injectivity modeling. The topic and the mechanisms we show are of general interest for drying processes in porous material such as soils and paper.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ahrens, L.
2010-11-01
The objective of this note is to (once again) explore the AGS 'ORM' (orbit response matrix) data taken (by Operations) early during the 2007 run with an AGS bare machine and gold beam. Indeed the present motivation is to extract as much information about the AGS inherent transverse coupling as possible - from general arguments and the copious ORM data. And taking this one step further, (though not accomplished yet) the goal really should be to tell the model how to describe this coupling. 'Bare' as used here means the AGS with no quadrupole, sextupole or octupole magnets powered. Onlymore » the main (combined-function) magnet string and dipole bumps necessary to optimize beam survival are powered. 'ORM data' means the systematic recording of the equilibrium orbit beam position monitor response to powering individual dipole corrector magnets. The 'matrix' results from looking at the effect of each of the (12 superperiods X 4 dipoles per superperiod) 'kicks' on each of the (12 X 6) pick up electrodes (pues) in each transverse plane. So then we have two (48 X 72) matrices of numbers from the ORM data. (Though 'pue' usually refers to the hardware in the vacuum chamber and 'bpm' to the beam position monitoring system, the two labels will be used casually here.) The exercise is carried out at two magnet rigidities, injection (AGS field {approx}434 Gauss) and extraction to RHIC ({approx}9730 Gauss), - a ratio of rigidities of about 22.4. Since we stick with a bare machine, we are also stuck with the bare tunes which means the tunes are rather close together and near 8.75. Injection: (h,v) {approx} (8.73, 8.76).« less
Analytical expressions for stability regions in the Ince-Strutt diagram of Mathieu equation
NASA Astrophysics Data System (ADS)
Butikov, Eugene I.
2018-04-01
Simple analytical expressions are suggested for transition curves that separate, in the Ince-Strutt diagram, different types of solutions to the famous Mathieu equation. The derivations of these expressions in this paper rely on physically meaningful periodic solutions describing various regular motions of a familiar nonlinear mechanical system—a rigid planar pendulum with a vertically oscillating pivot. The paper is accompanied by a relevant simulation program.
Reply to ``Comment on `Free surface Hele-Shaw flows around an obstacle: A random walk simulation' ''
NASA Astrophysics Data System (ADS)
Bogoyavlenskiy, Vladislav A.; Cotts, Eric J.
2007-09-01
As pointed out by Vasconcelos in his Comment, our computer simulations of Hele-Shaw flows around series of wedges differ from analytical solutions existing for this problem. We attribute the discrepancy to the notion that these analytical solutions correspond to ideal, steady-state flow regimes which are hardly applicable when a rigid obstacle interacts with a moving liquid-gas interface.
Injectable Hydrogels for Cardiac Tissue Repair after Myocardial Infarction
Khattab, Ahmad; Islam, Mohammad Ariful; Hweij, Khaled Abou; Zeitouny, Joya; Waters, Renae; Sayegh, Malek; Hossain, Md Monowar; Paul, Arghya
2015-01-01
Cardiac tissue damage due to myocardial infarction (MI) is one of the leading causes of mortality worldwide. The available treatments of MI include pharmaceutical therapy, medical device implants, and organ transplants, all of which have severe limitations including high invasiveness, scarcity of donor organs, thrombosis or stenosis of devices, immune rejection, and prolonged hospitalization time. Injectable hydrogels have emerged as a promising solution for in situ cardiac tissue repair in infarcted hearts after MI. In this review, an overview of various natural and synthetic hydrogels for potential application as injectable hydrogels in cardiac tissue repair and regeneration is presented. The review starts with brief discussions about the pathology of MI, its current clinical treatments and their limitations, and the emergence of injectable hydrogels as a potential solution for post MI cardiac regeneration. It then summarizes various hydrogels, their compositions, structures and properties for potential application in post MI cardiac repair, and recent advancements in the application of injectable hydrogels in treatment of MI. Finally, the current challenges associated with the clinical application of injectable hydrogels to MI and their potential solutions are discussed to help guide the future research on injectable hydrogels for translational therapeutic applications in regeneration of cardiac tissue after MI. PMID:27668147
Ocean Tidal Dynamics and Dissipation in the Thick Shell Worlds
NASA Astrophysics Data System (ADS)
Hay, H.; Matsuyama, I.
2017-12-01
Tidal dissipation in the subsurface oceans of icy satellites has so far only been explored in the limit of a free-surface ocean or under the assumption of a thin ice shell. Here we consider ocean tides in the opposite limit, under the assumption of an infinitely rigid, immovable, ice shell. This assumption forces the surface displacement of the ocean to remain zero, and requires the solution of a pressure correction to ensure that the ocean is mass conserving (divergence-free) at all times. This work investigates the effect of an infinitely rigid lid on ocean dynamics and dissipation, focusing on implications for the thick shell worlds Ganymede and Callisto. We perform simulations using a modified version of the numerical model Ocean Dissipation in Icy Satellites (ODIS), solving the momentum equations for incompressible shallow water flow under a degree-2 tidal forcing. The velocity solution to the momentum equations is updated iteratively at each time-step using a pressure correction to guarantee mass conservation everywhere, following a standard solution procedure originally used in solving the incompressible Navier-Stokes equations. We reason that any model that investigates ocean dynamics beneath a global ice layer should be tested in the limit of an immovable ice shell and must yield solutions that exhibit divergence-free flow at all times.
Computed tomography analysis of third webspace injections for interdigital neuroma.
Hembree, W Chad; Groth, Adam T; Schon, Lew C; Guyton, Gregory P
2013-04-01
Injection for interdigital neuroma (IDN) may not selectively target the common digital nerve. We investigated the anatomical localization and extent of extravasation with injection for IDN. Two fellowship-trained foot and ankle surgeons injected radiopaque contrast into the third webspace of 49 cadaveric specimens (29 with 2 mL and 20 with 1 mL). Computed tomography scan of each specimen was obtained. An independent blinded foot and ankle surgeon analyzed the scans. All injections were accurate. Contrast was found in the second (greater than 70%) and fourth (greater than 30%) webspaces in both injection volume groups. No contrast was found within the third metatarsophalangeal joint. Extravasation extent was significantly greater with 2 mL versus 1 mL of solution in the medial to lateral (27.9 [7.8] mm vs 23.7 [6.0] mm; P = .05) and distal to proximal (52.1 [13.7] mm vs 40.4 [16.1] mm; P = .01) planes. No differences were observed in extravasation extent between surgeons. Injection for IDN was accurate, and extravasation extended into adjacent webspaces in a large percentage of specimens with both solution volumes. Lower extent of extravasation with 1 mL of solution did not indicate better selectivity of injection. Steroid injections for interdigital neuroma were accurate for therapeutic purposes but not diagnostic, except potentially for distinguishing webspace pain from joint pain.
Karlsson, Niklas; Santacatterina, Michele; Käll, Kerstin; Hägerstrand, Maria; Wallin, Susanne; Berglund, Torsten; Ekström, Anna Mia
2017-08-16
People who inject drugs (PWID) frequently engage in injection risk behaviours exposing them to blood-borne infections. Understanding the underlying causes that drive various types and levels of risk behaviours is important to better target preventive interventions. A total of 2150 PWID in Swedish remand prisons were interviewed between 2002 and 2012. Questions on socio-demographic and drug-related variables were asked in relation to the following outcomes: Having shared injection drug solution and having lent out or having received already used drug injection equipment within a 12 month recall period. Women shared solutions more than men (odds ratio (OR) 1.51, 95% confidence interval (CI) 1.03; 2.21). Those who had begun to inject drugs before age 17 had a higher risk (OR 1.43, 95% CI 0.99; 2.08) of having received used equipment compared to 17-19 year olds. Amphetamine-injectors shared solutions more than those injecting heroin (OR 2.43, 95% CI 1.64; 3.62). A housing contract lowered the risk of unsafe injection by 37-59% compared to being homeless. Women, early drug debut, amphetamine users and homeless people had a significantly higher level of injection risk behaviour and need special attention and tailored prevention to successfully combat hepatitis C and HIV transmission among PWID. ClinicalTrials.gov Identifier, NCT02234167.
75 FR 9333 - Implantation or Injectable Dosage Form New Animal Drugs; Tilmicosin
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-02
.... FDA-2010-N-0002] Implantation or Injectable Dosage Form New Animal Drugs; Tilmicosin AGENCY: Food and... dose range for use of an injectable solution of tilmicosin phosphate for treatment of respiratory... 300 (tilmicosin injection, USP) Injection, available by veterinary prescription for use in the...
Matching multiple rigid domain decompositions of proteins
Flynn, Emily; Streinu, Ileana
2017-01-01
We describe efficient methods for consistently coloring and visualizing collections of rigid cluster decompositions obtained from variations of a protein structure, and lay the foundation for more complex setups that may involve different computational and experimental methods. The focus here is on three biological applications: the conceptually simpler problems of visualizing results of dilution and mutation analyses, and the more complex task of matching decompositions of multiple NMR models of the same protein. Implemented into the KINARI web server application, the improved visualization techniques give useful information about protein folding cores, help examining the effect of mutations on protein flexibility and function, and provide insights into the structural motions of PDB proteins solved with solution NMR. These tools have been developed with the goal of improving and validating rigidity analysis as a credible coarse-grained model capturing essential information about a protein’s slow motions near the native state. PMID:28141528
Polymer Architecture Effects in Confined Geometry: Molecular Dynamics Simulation Study
NASA Astrophysics Data System (ADS)
Wijesinghe, Sidath; Perahia, Dvora; Grest, Gary
Luminescent rigid polymers confined into nanoparticles, or polydots, are emerging as a promising tool for nano medicine. The constrained architecture of a rigid backbone trapped in nano-dimensions results in photophysics that differs from that of spontaneously assembled rigid polymers. Incorporating ionizable functionalities in the polymers, often required for therapeutics, impacts the polymer conformation in solution. Here we report fully atomistic molecular dynamics simulations on the structure of dialkyl p-phenylene ethynylene confined into polydots. We find that the structure and thermal stability of polydots are sensitive to both the molecular weight n and the carboxylation fraction f. At room temperature , polydots remain confined regardless of n and f . However, as temperature is increased, polydots with lower n or f rearrange whereas polydots with higher n or fremain confined, though no direct clustering of the ionic groups was observed. NSF CHE 1308298 is acknowledged.
NASA Astrophysics Data System (ADS)
Mokhtar, N. F. M.; Khalid, I. K.; Siri, Z.; Ibrahim, Z. B.; Gani, S. S. A.
2017-10-01
The influences of feedback control and internal heat source on the onset of Rayleigh-Bénard convection in a horizontal nanofluid layer is studied analytically due to Soret and Dufour parameters. The confining boundaries of the nanofluid layer (bottom boundary-top boundary) are assumed to be free-free, rigid-free, and rigid-rigid, with a source of heat from below. Linear stability theory is applied, and the eigenvalue solution is obtained numerically using the Galerkin technique. Focusing on the stationary convection, it is shown that there is a positive thermal resistance in the presence of feedback control on the onset of double-diffusive convection, while there is a positive thermal efficiency in the existence of internal heat generation. The possibilities of suppress or augment of the Rayleigh-Bénard convection in a nanofluid layer are also discussed in detail.
Rigidity of Major Plates and Microplates Estimated From GPS Solution GPS2006.0
NASA Astrophysics Data System (ADS)
Kogan, M. G.; Steblov, G. M.
2006-05-01
Here we analyze the rigidity of eight major lithospheric plates using our global GPS solution GPS2006.0. We included all daily observations in interval 1995.0 to 2006.0 collected at IGS stations, as well as observations at many important stations not included in IGS. Loose multiyear solution GPS2006.0 is based on daily solutions by GAMIT software, performed at SOPAC and at Columbia University; those daily solutions were combined by Kalman filter (GLOBK software) into a loose multiyear solution. The constrained solution for station positions and velocities was obtained without a conventional reference frame; instead, we applied translation and rotation in order to best fit the zero velocities of 76 stations in stable plate cores excluding the regions of postglacial rebound. Simultaneously, we estimated relative plate rotation vectors (RV) and the origin translation rate (OTR), and then corrected station velocities for it. Therefore, the velocities in GPS2006.0 are unaffected by the OTR error of ITRF2000 conventionally used to constrain a loose solution. The 1-sigma plate-residual velocity in a stable plate core is less than 1 mm/yr for the plates: Eurasia, Pacific, North and South Americas, Nubia, Australia, and Antarctica; it is 1.4 mm/yr for the Indian plate, most probably because of poorer data quality. Plate-residuals at other established plates (Arabia, Nazca, Caribbean, Philippine) were not assessed for lack of observations. From our analysis, an upper bound for the mobility of the plate inner area is 1 mm/yr. Plate- residual GPS velocities for several hypothesized microplates in east Asia, such as Okhotsk, Amuria, South China, are 3-4 times higher; corresponding strain rates for these microplates are an order of magnitude higher than for Eurasia, North America, and other large plates.
Jeon, Jonggu; Chun, Myung-Suk
2007-04-21
Understanding the behavior of a polyelectrolyte in confined spaces has direct relevance in design and manipulation of microfluidic devices, as well as transport in living organisms. In this paper, a coarse-grained model of anionic semiflexible polyelectrolyte is applied, and its structure and dynamics are fully examined with Brownian dynamics (BD) simulations both in bulk solution and under confinement between two negatively charged parallel plates. The modeling is based on the nonlinear bead-spring discretization of a continuous chain with additional long-range electrostatic, Lennard-Jones, and hydrodynamic interactions between pairs of beads. The authors also consider the steric and electrostatic interactions between the bead and the confining wall. Relevant model parameters are determined from experimental rheology data on the anionic polysaccharide xanthan reported previously. For comparison, both flexible and semiflexible models are developed accompanying zero and finite intrinsic persistence lengths, respectively. The conformational changes of the polyelectrolyte chain induced by confinements and their dependence on the screening effect of the electrolyte solution are faithfully characterized with BD simulations. Depending on the intrinsic rigidity and the medium ionic strength, the polyelectrolyte can be classified as flexible, semiflexible, or rigid. Confined flexible and semiflexible chains exhibit a nonmonotonic variation in size, as measured by the radius of gyration and end-to-end distance, with changing slit width. For the semiflexible chain, this is coupled to the variations in long-range bond vector correlation. The rigid chain, realized at low ionic strength, does not have minima in size but exhibits a sigmoidal transition. The size of confined semiflexible and rigid polyelectrolytes can be well described by the wormlike chain model once the electrostatic effects are taken into account by the persistence length measured at long length scale.
Advocacy for Gender Affirming Care: Learning from the Injectable Estrogen Shortage.
Geffen, Sophia; Horn, Tim; Smith, Kimberleigh Joy; Cahill, Sean
2018-01-01
Hormone therapy is medically necessary for many transgender individuals. The U.S. Food and Drug Administration (FDA) and pharmaceutical companies' failure to guarantee a supply of injectable estrogen in 2016 and 2017 for transgender individuals is a violation of their right to comprehensive medical treatment, free of discrimination. A series of advocacy actions eventually led to all formulations of injectable estrogen being restored to market; however, long-term solutions to supply interruptions of injectable estrogen are needed. Long-term solutions should address the lack of federally funded research and, consequently, evidence-based practice on hormone therapy for gender affirmation.
Han, Ying; Lam, Har Hiu; Stewart, Jay M
2009-06-01
A 31-year-old woman presented with visual acuity of counting fingers and presumed bacterial endophthalmitis in the left eye 10 days after refractive surgery. During the procedure, a retrobulbar injection of balanced salt solution had been performed to assist with globe suction by the microkeratome. A perforation site was identified in the inferonasal retina. Following intravitreal antibiotic injection and surgical intervention, the visual acuity returned to 20/20. Retrobulbar injection to facilitate laser in situ keratomileusis carries risks. Careful monitoring for signs of infection is recommended if globe perforation is recognized.
Preconditioning the Helmholtz Equation for Rigid Ducts
NASA Technical Reports Server (NTRS)
Baumeister, Kenneth J.; Kreider, Kevin L.
1998-01-01
An innovative hyperbolic preconditioning technique is developed for the numerical solution of the Helmholtz equation which governs acoustic propagation in ducts. Two pseudo-time parameters are used to produce an explicit iterative finite difference scheme. This scheme eliminates the large matrix storage requirements normally associated with numerical solutions to the Helmholtz equation. The solution procedure is very fast when compared to other transient and steady methods. Optimization and an error analysis of the preconditioning factors are present. For validation, the method is applied to sound propagation in a 2D semi-infinite hard wall duct.
2014-09-01
and 20 “live” tweets were injected into the scenario itself 1 alternative power demonstration ( wind and solar) accomplished 7 remote wireless ...solved this issue. 2. Hastily Formed Networks (HFN) Alternative power sources were set up:RENEWS–a wind turbine , flexible solar panels, rigid...297 WORKS CONSULTED Akyildiz, I. (2011). Sensor networks in challenged environments. Wireless Technologies for Humanitarian Relief, 3(3).doi
Process and apparatus for producing ultrafine explosive particles
McGowan, Michael J.
1992-10-20
A method and an improved eductor apparatus for producing ultrafine explosive particles is disclosed. The explosive particles, which when incorporated into a binder system, have the ability to propagate in thin sheets, and have very low impact sensitivity and very high propagation sensitivity. A stream of a solution of the explosive dissolved in a solvent is thoroughly mixed with a stream of an inert nonsolvent by obtaining nonlaminar flow of the streams by applying pressure against the flow of the nonsolvent stream, to thereby diverge the stream as it contacts the explosive solution, and violently agitating the combined stream to rapidly precipitate the explosive particles from the solution in the form of generally spheroidal, ultrafine particles. The two streams are injected coaxially through continuous, concentric orifices of a nozzle into a mixing chamber. Preferably, the nonsolvent stream is injected centrally of the explosive solution stream. The explosive solution stream is injected downstream of and surrounds the nonsolvent solution stream for a substantial distance prior to being ejected into the mixing chamber.
NASA Astrophysics Data System (ADS)
Ishii, K.; Watanabe, S.; Obata, D.; Hazama, H.; Morita, Y.; Matsuoka, Y.; Kutsumi, H.; Azuma, T.; Awazu, K.
2010-02-01
Endoscopic submucosal dissection (ESD) is accepted as a minimally invasive treatment technique for small early gastric cancers. Procedures are carried out using some specialized electrosurgical knifes with a submucosal injection solution. However it is not widely used because its procedure is difficult. The objective of this study is to develop a novel ESD method which is safe in principle and widely used by using laser techniques. In this study, we used CO2 lasers with a wavelength of 10.6 μm for mucosal ablation. Two types of pulse, continuous wave and pulsed wave with a pulse width of 110 ns, were studied to compare their values. Porcine stomach tissues were used as a sample. Aqueous solution of sodium hyaluronate (MucoUpR) with 50 mg/ml sodium dihydrogenphosphate is injected to a submucosal layer. As a result, ablation effect by CO2 laser irradiation was stopped because submucosal injection solution completely absorbed CO2 laser energy in the invasive energy condition which perforates a muscle layer without submucosal injection solution. Mucosal ablation by the combination of CO2 Laser and a submucosal injection solution is a feasible technique for treating early gastric cancers safely because it provides a selective mucosal resection and less-invasive interaction to muscle layer.
Wu, Zimei; Tucker, Ian G; Razzak, Majid; McSporran, Keith; Medlicott, Natalie J
2010-07-01
The aim of the study was to investigate the tissue tolerance and bioavailability of four formulations containing 5% ricobendazole solubilised at low pH, following subcutaneous injection in sheep. Formulations were: a water-in-oil emulsion, a microemulsion, a hydroxypropyl-beta-cyclodextrin (HP-beta-CD, 20%) drug solution, and a low-pH drug solution (reference). In-vitro cytotoxicity of the formulations was investigated in L929 fibroblasts using MTS viability and lactate dehydrogenase leakage assays. Each formulation and respective vehicle was injected into either side of the back of a sheep to investigate the tissue tolerance and pharmacokinetics. In-vitro studies suggested that both the emulsion and the microemulsion are unlikely to give a burst release of the low-pH drug solution in aqueous media. The microemulsion showed the greatest in-vitro cytotoxic effect but no significant difference was observed between the other formulations. In sheep, the three new formulations and vehicles caused little or no injection-site reactions compared with a marked response to the reference formulation. Bioavailabilities of HP-beta-CD formulation, emulsion and microemulsion formulations, relative to the reference formulation, were 194, 155 and 115%, respectively. The three new subcutaneous injectables showed promise for reducing irritation of low-pH solubilised ricobendazole. HP-beta-CD significantly enhanced the drug absorption. Controlling the burst release of the low-pH drug solution may improve tissue tolerance and minimise post-injection precipitation, and hence increase drug bioavailability. The in-vitro cytotoxicity studies did not predict the in-vivo irritation effects.
The analysis of a nonsimilar laminar boundary layer
NASA Technical Reports Server (NTRS)
Stalmach, D. D.; Bertin, J. J.
1978-01-01
A computer code is described which yields accurate solutions for a broad range of laminar, nonsimilar boundary layers, providing the inviscid flow field is known. The boundary layer may be subject to mass injection for perfect-gas, nonreacting flows. If no mass injection is present, the code can be used with either perfect-gas or real-gas thermodynamic models. Solutions, ranging from two-dimensional similarity solutions to solutions for the boundary layer on the Space Shuttle Orbiter during reentry conditions, have been obtained with the code. Comparisons of these solutions, and others, with solutions presented in the literature; and with solutions obtained from other codes, demonstrate the accuracy of the present code.
Yan, Congqi; Mackay, Michael E.; Czymmek, Kirk; Nagarkar, Radhika P.; Schneider, Joel P.; Pochan, Darrin J.
2012-01-01
β-hairpin peptide-based hydrogels are a class of injectable solid hydrogels that can deliver encapsulated cells or molecular therapies to a target site via syringe or catheter injection as a carrier material. These physical hydrogels can shear-thin and consequently flow as a low-viscosity material under a sufficient shear stress but immediately recover back into a solid upon removal of the stress, allowing them to be injected as preformed gel solids. Hydrogel behavior during flow was studied in a cylindrical capillary geometry that mimicked the actual situation of injection through a syringe needle in order to quantify effects of shear-thin injection delivery on hydrogel flow behavior and encapsulated cell payloads. It was observed that all β-hairpin peptide hydrogels investigated displayed a promising flow profile for injectable cell delivery: a central wide plug flow region where gel material and cell payloads experienced little or no shear rate and a narrow shear zone close to the capillary wall where gel and cells were subject to shear deformation. The width of the plug flow region was found to be weakly dependent on hydrogel rigidity and flow rate. Live-dead assays were performed on encapsulated MG63 cells three hours after injection flow and revealed that shear-thin delivery through the capillary had little impact on cell viability and the spatial distribution of encapsulated cell payloads. These observations help us to fundamentally understand how the gels flow during injection through a thin catheter and how they immediately restore mechanically and morphologically relative to pre-flow, static gels. PMID:22390812
Höfle, Stefan; Schienle, Alexander; Bruns, Michael; Lemmer, Uli; Colsmann, Alexander
2014-05-01
Inverted device architectures for organic light-emitting diodes (OLEDs) require suitable interfaces or buffer layers to enhance electron injection from highwork-function transparent electrodes. A solution-processable combination of ZnO and PEI is reported, that facilitates electron injection and enables efficient and air-stable inverted devices. Replacing the metal anode by highly conductive polymers enables transparent OLEDs. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Device For Controlling Crystallization Of Protein
NASA Technical Reports Server (NTRS)
Noever, David A.
1993-01-01
Variable sandwich spacer enables optimization of evaporative driving force that governs crystallization of protein from solution. Mechanically more rigid than hanging-drop and sitting-drop devices. Large oscillations and dislodgment of drop of solution in response to vibrations suppressed by glass plates. Other advantages include: suitable for automated delivery, stable handling, and programmable evaporation of protein solution; controlled configuration enables simple and accurate determination of volume of solution without disrupting crystallization; pH and concentration of precipitant controlled dynamically because pH and concentration coupled to rate of evaporation, controllable via adjustment of gap between plates; and enables variation of ratio between surface area and volume of protein solution. Alternative version, plates oriented vertically instead of horizontally.
Analytic regularization of uniform cubic B-spline deformation fields.
Shackleford, James A; Yang, Qi; Lourenço, Ana M; Shusharina, Nadya; Kandasamy, Nagarajan; Sharp, Gregory C
2012-01-01
Image registration is inherently ill-posed, and lacks a unique solution. In the context of medical applications, it is desirable to avoid solutions that describe physically unsound deformations within the patient anatomy. Among the accepted methods of regularizing non-rigid image registration to provide solutions applicable to medical practice is the penalty of thin-plate bending energy. In this paper, we develop an exact, analytic method for computing the bending energy of a three-dimensional B-spline deformation field as a quadratic matrix operation on the spline coefficient values. Results presented on ten thoracic case studies indicate the analytic solution is between 61-1371x faster than a numerical central differencing solution.
Zarmi, Yair
2015-01-01
The (1+1)-dimensional Sine-Gordon equation passes integrability tests commonly applied to nonlinear evolution equations. Its kink solutions (one-dimensional fronts) are obtained by a Hirota algorithm. In higher space-dimensions, the equation does not pass these tests. Although it has been derived over the years for quite a few physical systems that have nothing to do with Special Relativity, the Sine-Gordon equation emerges as a non-linear relativistic wave equation. This opens the way for exploiting the tools of the Theory of Special Relativity. Using no more than the relativistic kinematics of tachyonic momentum vectors, from which the solutions are constructed through the Hirota algorithm, the existence and classification of N-moving-front solutions of the (1+2)- and (1+3)-dimensional equations for all N ≥ 1 are presented. In (1+2) dimensions, each multi-front solution propagates rigidly at one velocity. The solutions are divided into two subsets: Solutions whose velocities are lower than a limiting speed, c = 1, or are greater than or equal to c. To connect with concepts of the Theory of Special Relativity, c will be called "the speed of light." In (1+3)-dimensions, multi-front solutions are characterized by spatial structure and by velocity composition. The spatial structure is either planar (rotated (1+2)-dimensional solutions), or genuinely three-dimensional--branes. Planar solutions, propagate rigidly at one velocity, which is lower than, equal to, or higher than c. Branes must contain clusters of fronts whose speed exceeds c = 1. Some branes are "hybrids": different clusters of fronts propagate at different velocities. Some velocities may be lower than c but some must be equal to, or exceed, c. Finally, the speed of light cannot be approached from within the subset of slower-than-light solutions in both (1+2) and (1+3) dimensions.
Monitoring TCE Degradation by In-situ Bioremediation in TCE-Contaminated site
NASA Astrophysics Data System (ADS)
Han, K.; Hong, U.; Ahn, G.; Jiang, H.; Yoo, H.; Park, S.; Kim, N.; Ahn, H.; Kwon, S.; Kim, Y.
2012-12-01
Trichloroethylene (TCE) is a long-term common groundwater pollutant because the compound with high density is slowly released into groundwater. Physical and chemical remediation processes have been used to clean-up the contaminant, but novel remediation technology is required to overcome a low efficiency of the traditional treatment process. Many researchers focused on biological process using an anaerobic TCE degrading culture, but it still needs to evaluate whether the process can be applied into field scale under aerobic condition. Therefore, in this work we investigated two different tests (i.e., biostimulation and bioaugmentation) of biological remediation through the Well-to-Well test (injection well to extraction well) in TCE-contaminated site. Also solutions (Electron donor & acceptor, tracer) were injected into the aquifer using a liquid coupled with nitrogen gas sparging. In biostimulation, we use 3 phases to monitoring biological remediation. Phase 1: we inject formate solution to get electron donor hydrogen (hydrogen can be generated from fermentation of formate). We also inject bromide as tracer. Phase 2: we made injection solution by formate, bromide and sulfate. The reason why we inject sulfate is that as a kind of electron accepter, sulfate reduction process is helpful to create anaerobic condition. Phase 3: we inject mixed solution made by formate, sulfate, fumarate, and bromide. The degradation of fumarate has the same mechanism and condition with TCE degradation, so we added fumarate to make sure that if the anaerobic TCE degradation by indigenous microorganisms started up (Because low TCE concentration by gas sparging). In the bioaugmentation test, we inject the Evanite culture (containing dehalococcoides spp) and TCE degradation to c-DCE, VC, ETH was monitored. We are evaluating the transport of the Evanite culture in the field by measuring TCE and VC reductases.
Accuracy limit of rigid 3-point water models
NASA Astrophysics Data System (ADS)
Izadi, Saeed; Onufriev, Alexey V.
2016-08-01
Classical 3-point rigid water models are most widely used due to their computational efficiency. Recently, we introduced a new approach to constructing classical rigid water models [S. Izadi et al., J. Phys. Chem. Lett. 5, 3863 (2014)], which permits a virtually exhaustive search for globally optimal model parameters in the sub-space that is most relevant to the electrostatic properties of the water molecule in liquid phase. Here we apply the approach to develop a 3-point Optimal Point Charge (OPC3) water model. OPC3 is significantly more accurate than the commonly used water models of same class (TIP3P and SPCE) in reproducing a comprehensive set of liquid bulk properties, over a wide range of temperatures. Beyond bulk properties, we show that OPC3 predicts the intrinsic charge hydration asymmetry (CHA) of water — a characteristic dependence of hydration free energy on the sign of the solute charge — in very close agreement with experiment. Two other recent 3-point rigid water models, TIP3PFB and H2ODC, each developed by its own, completely different optimization method, approach the global accuracy optimum represented by OPC3 in both the parameter space and accuracy of bulk properties. Thus, we argue that an accuracy limit of practical 3-point rigid non-polarizable models has effectively been reached; remaining accuracy issues are discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Q Ma; B Mao; P Cebe
2011-12-31
We investigate the interaction of the polymer matrix and filler in electrospun nanofibers using advanced thermal analysis methods. In particular, we study the ability of silicon dioxide nanoparticles to affect the phase structure of poly(ethylene terephthalate), PET. SiO{sub 2} nanoparticles (either unmodified or modified with silane) ranging from 0 to 2.0 wt% in PET were electrospun from hexafluoro-2-propanol solutions. The morphologies of both the electrospun (ES) nanofibers and the SiO{sub 2} powders were observed by scanning and transmission electron microscopy, while the amorphous or crystalline nature of the fibers was determined by real-time wide-angle X-ray scattering. The fractions of themore » crystal, mobile amorphous, and rigid amorphous phases of the non-woven, nanofibrous composite mats were quantified by using heat capacity measurements. The amount of the immobilized polymer layer, the rigid amorphous fraction, was obtained from the specific reversing heat capacity for both as-spun amorphous fibers and isothermally crystallized fibers. Existence of the rigid amorphous phase in the absence of crystallinity was verified in nanocomposite fibers, and two origins for confinement of the rigid amorphous fraction are proposed. Thermal analysis of electrospun fibers, including quasi-isothermal methods, provides new insights to quantitatively characterize the polymer matrix phase structure and thermal transitions, such as devitrification of the rigid amorphous fraction.« less
Template-Based 3D Reconstruction of Non-rigid Deformable Object from Monocular Video
NASA Astrophysics Data System (ADS)
Liu, Yang; Peng, Xiaodong; Zhou, Wugen; Liu, Bo; Gerndt, Andreas
2018-06-01
In this paper, we propose a template-based 3D surface reconstruction system of non-rigid deformable objects from monocular video sequence. Firstly, we generate a semi-dense template of the target object with structure from motion method using a subsequence video. This video can be captured by rigid moving camera orienting the static target object or by a static camera observing the rigid moving target object. Then, with the reference template mesh as input and based on the framework of classical template-based methods, we solve an energy minimization problem to get the correspondence between the template and every frame to get the time-varying mesh to present the deformation of objects. The energy terms combine photometric cost, temporal and spatial smoothness cost as well as as-rigid-as-possible cost which can enable elastic deformation. In this paper, an easy and controllable solution to generate the semi-dense template for complex objects is presented. Besides, we use an effective iterative Schur based linear solver for the energy minimization problem. The experimental evaluation presents qualitative deformation objects reconstruction results with real sequences. Compare against the results with other templates as input, the reconstructions based on our template have more accurate and detailed results for certain regions. The experimental results show that the linear solver we used performs better efficiency compared to traditional conjugate gradient based solver.
A solution of the geodetic boundary value problem to order e3
NASA Technical Reports Server (NTRS)
Mather, R. S.
1973-01-01
A solution is obtained for the geodetic boundary value problem which defines height anomalies to + or - 5 cm, if the earth were rigid. The solution takes into account the existence of the earth's topography, together with its ellipsoidal shape and atmosphere. A relation is also established between the commonly used solution of Stokes and a development correct to order e cubed. The data requirements call for a complete definition of gravity anomalies at the surface of the earth and a knowledge of elevation characteristics at all points exterior to the geoid. In addition, spherical harmonic representations must be based on geocentric rather than geodetic latitudes.
NASA Astrophysics Data System (ADS)
Volkov, K. N.; Emelyanov, V. N.; Yakovchuk, M. S.
2017-11-01
The transverse injection of a pulsed jet into a supersonic flow for thrust vectoring in solid rocket motors is investigated. The gas flow through the injection nozzle is controlled by a piston which performs reciprocating motion. Reynolds-averaged Navier-Stokes equations and the ( k- ɛ) turbulence model equations are discretized using the finite volume method and moving grids. The pressure distributions on the plate surface obtained using various approaches to the description of the flow field and difference schemes are compared. The solution obtained for the case of injection of a pulsed jet is compared with the solution for the case where a valve prevents gas flow through the injection nozzle. The dependence of the control force produced by gas injection on time is investigated.
Dabarakis, Nikolaos N; Alexander, Veis; Tsirlis, Anastasios T; Parissis, Nikolaos A; Nikolaos, Maroufidis
2007-01-01
To clinically evaluate the jet injection Injex (Rösch AG Medizintechnik) using 2 different anesthetic solutions, and to compare the jet injection and the standard needle injection techniques. Of the 32 patients in the study, 10 received mepivacaine 3% anesthetic solution by means of the jet injection technique, while the remaining 22 patients received lidocaine 2% with epinephrine 1:80,000 by the same method. The 14 patients in whom pulp anesthesia was achieved were selected for an additional evaluation of the pulp reaction using standard needle injection anesthesia. The differences between the 2 compounds with Injex were statistically evaluated by means of independent-samples t test analysis. The differences between subgroups receiving both jet injection and needle injection anesthesia were evaluated by means of paired t test analysis. The administration of mepivacaine 3% using Injex did not achieve pulp anesthesia in any of the 10 patients, although the soft tissue anesthesia was successful. The administration of lidocaine with epinephrine using Injex resulted in pulp anesthesia in only 14 patients; soft tissue anesthesia was observed in all patients of this group. There was no statistically significant difference between Injex and the needle injection technique in onset of anesthesia. However, the duration of anesthesia was significantly longer for the needle infiltration group than for the Injex injection group. The anesthetic solution should be combined with a vasoconstriction agent when the Injex technique is implemented.
Rathbun, R.E.
1979-01-01
Measuring the reaeration coefficient of a stream with a modified tracer technique has been accomplished by injecting either ethylene or ethylene and propane together and a rhodamine-WT dye solution into the stream. The movement of the tracers through the stream reach after injection is described by a one-dimensional diffusion equation. The peak concentrations of the tracers at the downstream end of the reach depend on the concentrations of the tracers in the stream at the injection site, the longitudinal dispersion coefficient, the mean water velocity, the length of the reach, and the duration of the injection period. The downstream gas concentrations also depend on the gas desorption coefficients of the reach. The concentrations of the tracer gases in the stream at the injection site depend on the flow rates of the gases through the injection diffusers, the efficiency of the gas absorption process, and the stream discharge. The concentration of dye in the stream at the injection site depends on the flow rate of the dye solution, the concentration of the dye solution, and the stream discharge. Equations for estimating the gas flow rates, the quantities of the gases, the dye concentration, and the quantity of dye together with procedures for determining the variables in these equations are presented. (Woodard-USGS)
Zinc oxide films chemically grown onto rigid and flexible substrates for TFT applications
NASA Astrophysics Data System (ADS)
Suchea, M.; Kornilios, N.; Koudoumas, E.
2010-10-01
This contribution presents some preliminary results regarding the use of a chemical route for the growth of good quality ZnO thin films that can be used for the fabrication of thin film transistors (TFTs). The films were grown at rather low temperature (60 °C) on glass and PET substrates using non-aqueous (zinc acetate dihydrate in methanol) precursor solution and their surface morphology, crystalline structure, optical transmittance and electrical characteristics were studied. The study indicated that good quality films with desirable ZnO structure onto rigid and flexible substrates can be obtained, using a simple, cheap, low temperature chemical growth method.
NASA Technical Reports Server (NTRS)
Liu, J. J. F.; Fitzpatrick, P. M.
1975-01-01
A mathematical model is developed for studying the effects of gravity gradient torque on the attitude stability of a tumbling triaxial rigid satellite. Poisson equations are used to investigate the rotation of the satellite (which is in elliptical orbit about an attracting point mass) about its center of mass. An averaging method is employed to obtain an intermediate set of differential equations for the nonresonant, secular behavior of the osculating elements which describe the rotational motions of the satellite, and the averaged equations are then integrated to obtain long-term secular solutions for the osculating elements.
The Modified Hartmann Potential Effects on γ-rigid Bohr Hamiltonian
NASA Astrophysics Data System (ADS)
Suparmi, A.; Cari, C.; Nur Pratiwi, Beta
2018-04-01
In this paper, we present the solution of Bohr Hamiltonian in the case of γ-rigid for the modified Hartmann potential. The modified Hartmann potential was formed from the original Hartmann potential, consists of β function and θ function. By using the separation method, the three-dimensional Bohr Hamiltonian equation was reduced into three one-dimensional Schrodinger-like equation which was solved analytically. The results for the wavefunction were shown in mathematically, while for the binding energy was solved numerically. The numerical binding energy for the presence of the modified Hartmann potential is lower than the binding energy value in the absence of modified Hartmann potential effect.
NASA Technical Reports Server (NTRS)
Zimmerman, M.
1979-01-01
The classical mechanics results for free precession which are needed in order to calculate the weak field, slow-motion, quadrupole-moment gravitational waves are reviewed. Within that formalism, algorithms are given for computing the exact gravitational power radiated and waveforms produced by arbitrary rigid-body freely-precessing sources. The dominant terms are presented in series expansions of the waveforms for the case of an almost spherical object precessing with a small wobble angle. These series expansions, which retain the precise frequency dependence of the waves, may be useful for gravitational astronomers when freely-precessing sources begin to be observed.
Inclined indentation of smooth wedge in rock mass
NASA Astrophysics Data System (ADS)
Chanyshev, AI; Podyminogin, GM; Lukyashko, OA
2018-03-01
The article focuses on the inclined rigid wedge indentation into a rigid-plastic half-plane of rocks with the Mohr–Coulomb-Mohr plasticity. The limiting loads on different sides of the wedge are determined versus the internal friction angle, cohesion and wedge angle. It is shown that when the force is applied along the symmetry axis of the wedge, the zone of plasticity is formed only on one wedge side. In order to form the plasticity zone on both sides of the wedge, it is necessary to apply the force asymmetrically relative to the wedge symmetry axis. An engineering solution for the asymmetrical case implementation is suggested.
Shock wave emission from laser-induced cavitation bubbles in polymer solutions.
Brujan, Emil-Alexandru
2008-09-01
The role of extensional viscosity on the acoustic emission from laser-induced cavitation bubbles in polymer solutions and near a rigid boundary is investigated by acoustic measurements. The polymer solutions consist of a 0.5% polyacrylamide (PAM) aqueous solution with a strong elastic component and a 0.5% carboxymethylcellulose (CMC) aqueous solution with a weak elastic component. A reduction of the maximum amplitude of the shock wave pressure and a prolongation of the oscillation period of the bubble were found in the elastic PAM solution. It might be caused by an increased resistance to extensional flow which is conferred upon the liquid by the polymer additive. In both polymer solutions, however, the shock pressure decays proportionally to r(-1) with increasing distance r from the emission centre.
Longoria, Javier A; Fujiwara, Miwa; Guerra, Catalina; Lee, Jeffrey L; Sassoon, Catherine S H; Mazdisnian, Farhad
2016-10-01
Expiratory central airway collapse is an increasingly recognized abnormality of the central airways and may be present in as many as 22% of patients evaluated for chronic obstructive pulmonary disease and/or asthma. Many current treatment options require invasive procedures that have been shown to cause significant morbidity and mortality. To test the hypothesis that Teflon injection will induce sufficient fibroblast proliferation and collagen deposition, we evaluated the time course on the effect of Teflon injection in the posterior membranous trachea on the histopathology of the tracheobronchial tree. Six Yucatan Pigs were assigned to undergo general anesthesia and injection of 0.3 to 0.5 mL of sterile Teflon paste in 50% glycerin into the posterior membranous tracheal wall. A control pig received an equivalent volume of glycerin. Animals were euthanized in predefined intervals and tracheas were excised and examined under light microscopy for identifying fibroblast proliferation and collagen deposition. Compared with the control pig, the Teflon injection site showed tissue reaction of fibrohistiocytic proliferation and subsequent collagen deposition in all animals. Furthermore, the increased fibroblast proliferation and collagen deposition were time dependent (P<0.01). This pilot study demonstrates histopathologic changes in the trachea after Teflon injection, comprised of increased fibroblast activity and collagen deposition that could be of potential use in creating greater airway rigidity in patients with sever diffuse excessive dynamic airway collapse.
[Skin necrosis resulting from the extravasation of intravenous injections].
Ikhefoulma, Soumaya; Mahiou, Abelhamid; Perillat, Isabelle
2012-09-01
Extravasation is the diffusion of a product injected intravenously into the perivascular or subcutaneous spaces. Skin necrosis of iatrogenic origin can be observed for example with a subcutaneous perfusion of solution containing potassium chloride or the extravasation of 30% hypertonic glucose serum. Whenever a product is injected, the administration route for which the product has obtained marketing authorisation must be respected and a perfusion time of at least 4 to 5 hours per litre of solution perfused must be observed.
Integrated Approach to the Dynamics and Control of Maneuvering Flexible Aircraft
NASA Technical Reports Server (NTRS)
Waszak, Martin R. (Technical Monitor); Meirovitch, Leonard; Tuzcu, Ilhan
2003-01-01
This work uses a fundamental approach to the problem of simulating the flight of flexible aircraft. To this end, it integrates into a single formulation the pertinent disciplines, namely, analytical dynamics, structural dynamics, aerodynamics, and controls. It considers both the rigid body motions of the aircraft, three translations (forward motion, sideslip and plunge) and three rotations (roll, pitch and yaw), and the elastic deformations of every point of the aircraft, as well as the aerodynamic, propulsion, gravity and control forces. The equations of motion are expressed in a form ideally suited for computer processing. A perturbation approach yields a flight dynamics problem for the motions of a quasi-rigid aircraft and an 'extended aeroelasticity' problem for the elastic deformations and perturbations in the rigid body motions, with the solution of the first problem entering as an input into the second problem. The control forces for the flight dynamics problem are obtained by an 'inverse' process and the feedback controls for the extended aeroservoelasticity problem are determined by the LQG theory. A numerical example presents time simulations of rigid body perturbations and elastic deformations about 1) a steady level flight and 2) a level steady turn maneuver.
A new pre-loaded beam geometric stiffness matrix with full rigid body capabilities
NASA Astrophysics Data System (ADS)
Bosela, P. A.; Fertis, D. G.; Shaker, F. J.
1992-09-01
Space structures, such as the Space Station solar arrays, must be extremely light-weight, flexible structures. Accurate prediction of the natural frequencies and mode shapes is essential for determining the structural adequacy of components, and designing a controls system. The tension pre-load in the 'blanket' of photovoltaic solar collectors, and the free/free boundary conditions of a structure in space, causes serious reservations on the use of standard finite element techniques of solution. In particular, a phenomenon known as 'grounding', or false stiffening, of the stiffness matrix occurs during rigid body rotation. The authors have previously shown that the grounding phenomenon is caused by a lack of rigid body rotational capability, and is typical in beam geometric stiffness matrices formulated by others, including those which contain higher order effects. The cause of the problem was identified as the force imbalance inherent in the formulations. In this paper, the authors develop a beam geometric stiffness matrix for a directed force problem, and show that the resultant global stiffness matrix contains complete rigid body mode capabilities, and performs very well in the diagonalization methodology customarily used in dynamic analysis.
Gao, Leyi; Patterson, Eric E; Shippy, Scott A
2006-02-01
A simple automated nanoliter scale injection device which allows for reproducible 5 nL sample injections from samples with a volume of <1 microL is successfully used for conventional capillary electrophoresis (CE) and Hadamard transform (HT) CE detection. Two standard fused silica capillaries are assembled axially through the device to function as an injection and a separation capillary. Sample solution is supplied to the injection capillary using pressure controlled with a solenoid valve. Buffer solution flows gravimetrically by the junction of the injection and separation capillaries and is also gated with a solenoid valve. Plugs of sample are pushed into the space between the injection and separation capillaries for electrokinectic injection. To evaluate the performance of the injection device, several optimizations are performed including the influence of flow rates, the injected sample volume and the control of the buffer transverse flow on the overall sensitivity. The system was then applied to HT-CE-UV detection for the signal-to-noise ratio (S/N) improvement of the nitric oxide (NO) metabolites, nitrite and nitrate. In addition, signal averaging was performed to explore the possibility of greater sensitivity enhancements compared to single injections.
Shin, Kwangho; Heo, Youngmoo; Park, Hyungpil; Chang, Sungho; Rhee, Byungohk
2013-12-12
In this study, we focus on making a double-sided metal plate with an internal structure, such as honeycomb. The stainless steel powder was used in the metal injection molding (MIM) process. The preliminary studies were carried out for the measurement of the viscosity of the stainless steel feedstock and for the prediction of the filling behavior through Computer Aided Engineering (CAE) simulation. PE (high density polyethylene (HDPE) and low density polyethylene (LDPE)) and polypropylene (PP) resins were used to make the sacrificed insert with a honeycomb structure using a plastic injection molding process. Additionally, these sacrificed insert parts were inserted in the metal injection mold, and the metal injection molding process was carried out to build a green part with rectangular shape. Subsequently, debinding and sintering processes were adopted to remove the sacrificed polymer insert. The insert had a suitable rigidity that was able to endure the filling pressure. The core shift analysis was conducted to predict the deformation of the insert part. The 17-4PH feedstock with a low melting temperature was applied. The glass transition temperature of the sacrificed polymer insert would be of a high grade, and this insert should be maintained during the MIM process. Through these processes, a square metal plate with a honeycomb structure was made.
Shin, Kwangho; Heo, Youngmoo; Park, Hyungpil; Chang, Sungho; Rhee, Byungohk
2013-01-01
In this study, we focus on making a double-sided metal plate with an internal structure, such as honeycomb. The stainless steel powder was used in the metal injection molding (MIM) process. The preliminary studies were carried out for the measurement of the viscosity of the stainless steel feedstock and for the prediction of the filling behavior through Computer Aided Engineering (CAE) simulation. PE (high density polyethylene (HDPE) and low density polyethylene (LDPE)) and polypropylene (PP) resins were used to make the sacrificed insert with a honeycomb structure using a plastic injection molding process. Additionally, these sacrificed insert parts were inserted in the metal injection mold, and the metal injection molding process was carried out to build a green part with rectangular shape. Subsequently, debinding and sintering processes were adopted to remove the sacrificed polymer insert. The insert had a suitable rigidity that was able to endure the filling pressure. The core shift analysis was conducted to predict the deformation of the insert part. The 17-4PH feedstock with a low melting temperature was applied. The glass transition temperature of the sacrificed polymer insert would be of a high grade, and this insert should be maintained during the MIM process. Through these processes, a square metal plate with a honeycomb structure was made. PMID:28788427
76 FR 3488 - Implantation or Injectable Dosage Form New Animal Drugs; Oxytetracycline and Flunixin
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-20
.... FDA-2010-N-0002] Implantation or Injectable Dosage Form New Animal Drugs; Oxytetracycline and Flunixin... combination drug injectable solution containing oxytetracycline and flunixin meglumine in cattle. [[Page 3489... veterinary prescription use of HEXASOL (oxytetracycline and flunixin meglumine) Injection for the treatment...
Modeling of the Temperature Field Recovery in the Oil Pool
NASA Astrophysics Data System (ADS)
Khabibullin, I. L.; Davtetbaev, A. Ya.; Mar'in, D. F.; Khisamov, A. A.
2018-05-01
This paper considers the problem on mathematical modeling of the temperature field recovery in the oil pool upon termination of injection of water into the pool. The problem is broken down into two stages: injection of water and temperature and pressure recovery upon termination of injection. A review of the existing mathematical models is presented, analytical solutions for a number of cases have been constructed, and a comparison of the analytical solutions of different models has been made. In the general form, the expression has been obtained that permits determining the temperature change in the oil pool upon termination of injection of water (recovery of the temperature field).
Advocacy for Gender Affirming Care: Learning from the Injectable Estrogen Shortage
Geffen, Sophia; Horn, Tim; Smith, Kimberleigh Joy; Cahill, Sean
2018-01-01
Abstract Hormone therapy is medically necessary for many transgender individuals. The U.S. Food and Drug Administration (FDA) and pharmaceutical companies' failure to guarantee a supply of injectable estrogen in 2016 and 2017 for transgender individuals is a violation of their right to comprehensive medical treatment, free of discrimination. A series of advocacy actions eventually led to all formulations of injectable estrogen being restored to market; however, long-term solutions to supply interruptions of injectable estrogen are needed. Long-term solutions should address the lack of federally funded research and, consequently, evidence-based practice on hormone therapy for gender affirmation. PMID:29682613
Development and characterization of a rapid polymerizing collagen for soft tissue augmentation.
Devore, Dale; Zhu, Jiaxun; Brooks, Robert; McCrate, Rebecca Rone; Grant, David A; Grant, Sheila A
2016-03-01
A liquid collagen has been developed that fibrilizes upon injection. Rapid polymerizing collagen (RPC) is a type I porcine collagen that undergoes fibrillization upon interaction with ionic solutions, such as physiological solutions. The ability to inject liquid collagen would be beneficial for many soft tissue augmentation applications. In this study, RPC was synthesized and characterized as a possible dermal filler. Transmission electron microscopy, ion induced RPC fibrillogenesis tests, collagenase resistance assay, and injection force studies were performed to assess RPC's physicochemical properties. An in vivo study was performed which consisted of a 1-, 3-, and 6-month study where RPC was injected into the ears of miniature swine. The results demonstrated that the liquid RPC requires low injection force (<7 N); fibrillogenesis and banding of collagen occurs when RPC is injected into ionic solutions, and RPC has enhanced resistance to collagenase breakdown. The in vivo study demonstrated long-term biocompatibility with low irritation scores. In conclusion RPC possesses many of the desirable properties of a soft tissue augmentation material. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 758-767, 2016. © 2015 The authors journal of biomedical materials research part a published by wiley periodicals, inc.
Development and characterization of a rapid polymerizing collagen for soft tissue augmentation
Devore, Dale; Zhu, Jiaxun; Brooks, Robert; McCrate, Rebecca Rone; Grant, David A.
2015-01-01
Abstract A liquid collagen has been developed that fibrilizes upon injection. Rapid polymerizing collagen (RPC) is a type I porcine collagen that undergoes fibrillization upon interaction with ionic solutions, such as physiological solutions. The ability to inject liquid collagen would be beneficial for many soft tissue augmentation applications. In this study, RPC was synthesized and characterized as a possible dermal filler. Transmission electron microscopy, ion induced RPC fibrillogenesis tests, collagenase resistance assay, and injection force studies were performed to assess RPC's physicochemical properties. An in vivo study was performed which consisted of a 1‐, 3‐, and 6‐month study where RPC was injected into the ears of miniature swine. The results demonstrated that the liquid RPC requires low injection force (<7 N); fibrillogenesis and banding of collagen occurs when RPC is injected into ionic solutions, and RPC has enhanced resistance to collagenase breakdown. The in vivo study demonstrated long‐term biocompatibility with low irritation scores. In conclusion RPC possesses many of the desirable properties of a soft tissue augmentation material. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 758–767, 2016. PMID:26488368
The febrile responses in rabbits and rats to leucocyte pyrogens of different species.
Borsook, D; Laburn, H; Mitchell, D
1978-01-01
1. We have investigated the effects on body temperature of rats and rabbits of leucocyte pyrogen derived from the blood of rat, rabbit, ox, pig and baboon. 2. In the rabbit intravenous injections (3.5 ml.) of solutions containing leucocyte pyrogen derived from ox, pig and rabbit blood produced fevers with short latencies; no fevers resulted from injections of similar solutions derived from rat or baboon blood. 3. In the rat intraperitoneal injections (2.0 ml.) of solutions containing leucocyte pyrogen derived from ox blood caused a fever, while pig leucocyte pyrogen produced a marked hypothermia. Neither rabbit, baboon, nor rat leucocyte pyrogen had any significant effect on rectal temperature of the rats. 4. Our results show that there is a variability of response in the rat and the rabbit to injection of leucocyte pyrogen of different species; leucocyte pyrogen may be species specific. PMID:671345
Apparatus and method for continuous production of materials
Chang, Chih-hung; Jin, Hyungdae
2014-08-12
Embodiments of a continuous-flow injection reactor and a method for continuous material synthesis are disclosed. The reactor includes a mixing zone unit and a residence time unit removably coupled to the mixing zone unit. The mixing zone unit includes at least one top inlet, a side inlet, and a bottom outlet. An injection tube, or plurality of injection tubes, is inserted through the top inlet and extends past the side inlet while terminating above the bottom outlet. A first reactant solution flows in through the side inlet, and a second reactant solution flows in through the injection tube(s). With reference to nanoparticle synthesis, the reactant solutions combine in a mixing zone and form nucleated nanoparticles. The nucleated nanoparticles flow through the residence time unit. The residence time unit may be a single conduit, or it may include an outer housing and a plurality of inner tubes within the outer housing.
New Whole-House Solutions Case Study: Shaw Construction, Aspen, Colorado
DOE Office of Scientific and Technical Information (OSTI.GOV)
none,
This builder worked with Building Science Corporation to design affordable HERS-54 townhouses with central solar radiator space heating, PV, R-28 closed-cell spray foam under slab and R-26 in advanced framed walls, and rigid polyiso on inside of basement walls
NASA Technical Reports Server (NTRS)
Fijany, Amir
1993-01-01
In this paper parallel 0(log N) algorithms for dynamic simulation of single closed-chain rigid multibody system as specialized to the case of a robot manipulatoar in contact with the environment are developed.
DOT National Transportation Integrated Search
2002-03-01
Rigid pavements make up a significant percentage of highway systems in the United States and abroad. Concrete pavements provide an economical and durable solution for highway systems, because the pavements last longer and require less maintenance. Re...
Crowe, Jacob D; Zarger, Rachael A; Hodge, David B
2017-10-04
Simultaneous chemical modification and physical reorganization of plant cell walls via alkaline hydrogen peroxide or liquid hot water pretreatment can alter cell wall structural properties impacting nanoscale porosity. Nanoscale porosity was characterized using solute exclusion to assess accessible pore volumes, water retention value as a proxy for accessible water-cell walls surface area, and solute-induced cell wall swelling to measure cell wall rigidity. Key findings concluded that delignification by alkaline hydrogen peroxide pretreatment decreased cell wall rigidity and that the subsequent cell wall swelling resulted increased nanoscale porosity and improved enzyme binding and hydrolysis compared to limited swelling and increased accessible surface areas observed in liquid hot water pretreated biomass. The volume accessible to a 90 Å dextran probe within the cell wall was found to be correlated to both enzyme binding and glucose hydrolysis yields, indicating cell wall porosity is a key contributor to effective hydrolysis yields.
Matrix methods applied to engineering rigid body mechanics
NASA Astrophysics Data System (ADS)
Crouch, T.
The purpose of this book is to present the solution of a range of rigorous body mechanics problems using a matrix formulation of vector algebra. Essential theory concerning kinematics and dynamics is formulated in terms of matrix algebra. The solution of kinematics and dynamics problems is discussed, taking into account the velocity and acceleration of a point moving in a circular path, the velocity and acceleration determination for a linkage, the angular velocity and angular acceleration of a roller in a taper-roller thrust race, Euler's theroem on the motion of rigid bodies, an automotive differential, a rotating epicyclic, the motion of a high speed rotor mounted in gimbals, and the vibration of a spinning projectile. Attention is given to the activity of a force, the work done by a conservative force, the work and potential in a conservative system, the equilibrium of a mechanism, bearing forces due to rotor misalignment, and the frequency of vibrations of a constrained rod.
NASA Astrophysics Data System (ADS)
Khe, A. K.; Cherevko, A. A.; Chupakhin, A. P.; Bobkova, M. S.; Krivoshapkin, A. L.; Orlov, K. Yu
2016-06-01
In this paper a computer simulation of a blood flow in cerebral vessels with a giant saccular aneurysm at the bifurcation of the basilar artery is performed. The modelling is based on patient-specific clinical data (both flow domain geometry and boundary conditions for the inlets and outlets). The hydrodynamic and mechanical parameters are calculated in the frameworks of three models: rigid-wall assumption, one-way FSI approach, and full (two-way) hydroelastic model. A comparison of the numerical solutions shows that mutual fluid- solid interaction can result in qualitative changes in the structure of the fluid flow. Other characteristics of the flow (pressure, stress, strain and displacement) qualitatively agree with each other in different approaches. However, the quantitative comparison shows that accounting for the flow-vessel interaction, in general, decreases the absolute values of these parameters. Solving of the hydroelasticity problem gives a more detailed solution at a cost of highly increased computational time.
Chiang, Bryce; Venugopal, Nitin; Grossniklaus, Hans E.; Jung, Jae Hwan; Edelhauser, Henry F.; Prausnitz, Mark R.
2017-01-01
Purpose To determine the effect of injection volume and formulation of a microneedle injection into the suprachoroidal space (SCS) on SCS thickness and closure kinetics. Methods Microneedle injections containing 25 to 150 μL Hanks' balanced salt solution (HBSS) were performed in the rabbit SCS ex vivo. Distribution of SCS thickness was measured by ultrasonography and three-dimensional (3D) cryo-reconstruction. Microneedle injections were performed in the rabbit SCS in vivo using HBSS, Discovisc, and 1% to 5% carboxymethyl cellulose (CMC) in HBSS. Ultrasonography was used to track SCS thickness over time. Results Increasing HBSS injection volume increased the area of expanded SCS, but did not increase SCS thickness ex vivo. With SCS injections in vivo, the SCS initially expanded to thicknesses of 0.43 ± 0.06 mm with HBSS, 1.5 ± 0.4 mm with Discovisc, and 0.69 to 2.1 mm with 1% to 5% CMC. After injection with HBSS, Discovisc, and 1% CMC solution, the SCS collapsed to baseline with time constants of 19 minutes, 6 hours, and 2.4 days, respectively. In contrast, injections with 3% to 5% CMC solution resulted in SCS expansion to 2.3 to 2.8 mm over the course of 2.8 to 9.1 hours, after which the SCS collapsed to baseline with time constants of 4.5 to 9.2 days. Conclusions With low-viscosity formulations, SCS expands to a thickness that remains roughly constant, independent of the volume of fluid injected. Increasing injection fluid viscosity significantly increased SCS thickness. Expansion of the SCS is hypothesized to be controlled by a balance between the viscous forces of the liquid formulation and the resistive biomechanical forces of the tissue. PMID:28125842
Chiang, Bryce; Venugopal, Nitin; Grossniklaus, Hans E; Jung, Jae Hwan; Edelhauser, Henry F; Prausnitz, Mark R
2017-01-01
To determine the effect of injection volume and formulation of a microneedle injection into the suprachoroidal space (SCS) on SCS thickness and closure kinetics. Microneedle injections containing 25 to 150 μL Hanks' balanced salt solution (HBSS) were performed in the rabbit SCS ex vivo. Distribution of SCS thickness was measured by ultrasonography and three-dimensional (3D) cryo-reconstruction. Microneedle injections were performed in the rabbit SCS in vivo using HBSS, Discovisc, and 1% to 5% carboxymethyl cellulose (CMC) in HBSS. Ultrasonography was used to track SCS thickness over time. Increasing HBSS injection volume increased the area of expanded SCS, but did not increase SCS thickness ex vivo. With SCS injections in vivo, the SCS initially expanded to thicknesses of 0.43 ± 0.06 mm with HBSS, 1.5 ± 0.4 mm with Discovisc, and 0.69 to 2.1 mm with 1% to 5% CMC. After injection with HBSS, Discovisc, and 1% CMC solution, the SCS collapsed to baseline with time constants of 19 minutes, 6 hours, and 2.4 days, respectively. In contrast, injections with 3% to 5% CMC solution resulted in SCS expansion to 2.3 to 2.8 mm over the course of 2.8 to 9.1 hours, after which the SCS collapsed to baseline with time constants of 4.5 to 9.2 days. With low-viscosity formulations, SCS expands to a thickness that remains roughly constant, independent of the volume of fluid injected. Increasing injection fluid viscosity significantly increased SCS thickness. Expansion of the SCS is hypothesized to be controlled by a balance between the viscous forces of the liquid formulation and the resistive biomechanical forces of the tissue.
Fluid flow characteristics during polymer flooding
NASA Astrophysics Data System (ADS)
Yao, S. L.; Dou, H. E.; Wu, M.; Zhang, H. J.
2018-05-01
At present the main problems of polymer flooding is the high injection pressure which could not guarantee the later injection. In this paper the analyses of polymer’s physical properties and its solution’s variable movement characteristics in porous media reveal the inevitable trend of decrease in injection capacity and liquid production due to the increase of fluid viscosity and flow rate with more flow resistance. The injection rate makes the primary contribution to the active viscosity of the polymer solution in porous media. The higher injection rate, the greater shearing degradation and the more the viscosity loss. Besides the quantitative variation, the rate also changes qualitatively as that the injection rate demonstrates composite change of injection intensity and density. Due to the different adjustment function of the polymer solution on its injection profile, there should be different adjustment model of rates in such stages. Here in combination of the on-site recognitions, several conclusions and recommendations are made based on the study of the injection pattern adjustment during polymer flooding to improve the pressure distribution system, which would be a meaningful reference for extensive polymer flooding in the petroleum industry.
Solute plumes mean velocity in aquifer transport: Impact of injection and detection modes
NASA Astrophysics Data System (ADS)
Dagan, Gedeon
2017-08-01
Flow of mean velocity U takes place in a heterogeneous aquifer of random spatially variable conductivity K. A solute plume is injected instantaneously along a plane normal to U, over a large area relative to the logconductivity integral scale I (ergodic plume). Transport is by advection by the spatially variable Eulerian velocity. The study is focused on the derivation of the mean plume velocity in the four modes set forth by Kreft and Zuber [1978] for one dimensional flow in a homogeneous medium. In the resident injection mode the mass is initially distributed uniformly in space while in the flux mode it is proportional to the local velocity. In the resident detection mode the mean velocity pertains to the plume centroid, whereas in flux detection it is quantified with the aid of the BTC and the corresponding mean arrival time. In agreement with the literature, it is shown that URR and UFF, pertaining to same injection and detection modes, either resident or flux, are equal to U. In contrast, in the mixed modes the solute velocity may differ significantly from U near the injection plane, approaching it at large distances relative to I. These effects are explained qualitatively with the aid of the exact solution for stratified aquifers.
Gao, Yuan; Li, Li; Zhang, Jianjun; Su, Feng; Gong, Zhenhua; Lai, Yisheng; Zhang, Yihua
2012-07-01
ZCVI(4)-2 was a novel nitric oxide-releasing glycosyl derivative of oleanolic acid that displayed strong cytotoxicity selectively against human hepatocellular carcinoma in vitro and in vivo. In this study, ZCVI(4)-2 was characterized by FT-IR spectroscopy, differential scanning calorimetry, powder X-ray diffractometry, Raman spectroscopy, hygroscopicity and stability. A high performance liquid chromatography method was also established for the quantitative determination of solubility and additional stability profile of ZCVI(4)-2. ZCVI(4)-2 was found to be an amorphous and stable solid with low solubility of less than 10 μg/mL. Based on the solubilization tests that included methods of cosolvency and micellization, the solution mixture of 5% Solutol HS-15, 5% 1, 2-propylene glycol and 5% anhydrous ethanol was determined to be the system for the preparation of the ZCVI(4)-2 early injection solution. The effect of pH, temperature, light and injectable isotonic glucose or NaCl solution on ZCVI(4)-2 injection was also investigated. Good stability was observed at all testing conditions. Under the conditions studied, the NO-releasing rate and amount of ZCVI(4)-2 from the early injection solution in rat plasma demonstrated a promising therapeutic efficacy while maintaining a good safety profile.
Heavily loaded joints for assembling aerobrake support trusses
NASA Technical Reports Server (NTRS)
Bandel, Hannskarl; Olsson, Nils; Levintov, Boris
1990-01-01
The major emphasis was to develop erectable joints for large aerobrake support trusses. The truss joints must be able to withstand the large forces experienced by the truss during the aero-pass, as well as be easily assembled and disassembled on orbit by astronauts or robots. Other important design considerations include; strength, stiffness, and allowable error in strut length. Six mechanical joint designs, as well as a seventh joint design, where a high strength epoxy is injected to make the connection rigid, are presented.
Alper, Michael; Meyer, Randal; Dekkers, Chris; Ezcurra, Diego; Schertz, Joan; Kelly, Eduardo
2008-01-01
Background The current study was designed to determine if follitropin alfa (recombinant human follicle-stimulating hormone; r-hFSH) and lutropin alfa (recombinant human luteinizing hormone; r-hLH) biopotencies were unchanged by reconstituting in sterile water for injection and mixing prior to injection. Methods The biopotencies of r-hFSH and r-hLH were determined following injection of female Sprague-Dawley rats with a mixture of follitropin alfa revised formulation female (RFF) and lutropin alfa (1:1, r-hFSH:r-hLH). Biopotencies of follitropin alfa RFF and lutropin alfa were measured using ovarian weight and ascorbic acid depletion assays, respectively, and compared with a reference standard. Stock mixtures of follitropin alfa RFF and lutropin alfa (1:1) were prepared within 1 h prior to each respective assay's injection and stored at 6 +/- 2°C. Separate low dose (follitropin alfa RFF 1.5 IU/rat, lutropin alfa 2 IU/rat) and high dose (follitropin alfa RFF 3 IU/rat, lutropin alfa 8 IU/rat) treatments were prepared from stock mixtures or individual solutions by diluting with 0.22% bovine serum albumin saline solution and injected within 1 h of preparation. The main outcome measures were ovarian weight and ovarian ascorbic acid depletion. Results FSH bioactivities were similar (p > 0.10) between the individual follitropin alfa RFF test solution (84.2 IU) and follitropin alfa RFF/lutropin alfa (87.6 IU) mixtures prepared within 1 h of injection and stored at 6 +/- 2°C. LH bioactivities were similar (p > 0.10) between lutropin alfa (94.7 IU) test solution and lutropin alfa/follitropin alfa RFF (85.3 IU) mixtures prepared within 1 h of injection and stored at 6 +/- 2°C for not more than 1 h prior to injection. Conclusion Mixing follitropin alfa RFF and lutropin alfa did not alter the bioactivity of either FSH or LH. PMID:18647398
21 CFR 522.1085 - Guaifenesin powder for injection.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 6 2014-04-01 2014-04-01 false Guaifenesin powder for injection. 522.1085 Section... § 522.1085 Guaifenesin powder for injection. (a) Specifications. The product is a sterile powder containing guaifenesin. A solution is prepared by dissolving the drug in sterile water for injection to make...
21 CFR 522.800 - Droperidol and fentanyl citrate injection.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Droperidol and fentanyl citrate injection. 522.800... § 522.800 Droperidol and fentanyl citrate injection. (a) Specifications. Droperidol and fentanyl citrate injection is a sterile solution containing 20 milligrams of droperidol and 0.4 milligram of fentanyl citrate...
21 CFR 522.800 - Droperidol and fentanyl citrate injection.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Droperidol and fentanyl citrate injection. 522.800... § 522.800 Droperidol and fentanyl citrate injection. (a) Specifications. Droperidol and fentanyl citrate injection is a sterile solution containing 20 milligrams of droperidol and 0.4 milligram of fentanyl citrate...
21 CFR 522.800 - Droperidol and fentanyl citrate injection.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Droperidol and fentanyl citrate injection. 522.800... § 522.800 Droperidol and fentanyl citrate injection. (a) Specifications. Droperidol and fentanyl citrate injection is a sterile solution containing 20 milligrams of droperidol and 0.4 milligram of fentanyl citrate...
NASA Astrophysics Data System (ADS)
Kaven, J. Ole; Barbour, Andrew J.; Ali, Tabrez
2017-04-01
Continual production of geothermal energy at times leads to significant surface displacement that can be observed in high spatial resolution using InSAR imagery. The surface displacement can be analyzed to resolve volume change within the reservoir revealing the often-complicated patterns of reservoir deformation. Simple point source models of reservoir deformation in a homogeneous elastic or poro-elastic medium can be superimposed to provide spatially varying, kinematic representations of reservoir deformation. In many cases, injection and production data are known in insufficient detail; but, when these are available, the same Green functions can be used to constrain the reservoir deformation. Here we outline how the injection and production data can be used to constrain bounds on the solution by posing the inversion as a quadratic programming with inequality constraints and regularization rather than a conventional least squares solution with regularization. We apply this method to InSAR-derived surface displacements at the Coso and Salton Sea Geothermal Fields in California, using publically available injection and production data. At both geothermal fields the available surface deformation in conjunction with the injection and production data permit robust solutions for the spatially varying reservoir deformation. The reservoir deformation pattern resulting from the constrained quadratic programming solution is more heterogeneous when compared to a conventional least squares solution. The increased heterogeneity is consistent with the known structural controls on heat and fluid transport in each geothermal reservoir.
Junsomboon, Jaroon; Jakmunee, Jaroon
2008-07-15
A simple flow injection system using three 3-way solenoid valves as an electric control injection valve and with a simple home-made chloride ion selective electrode based on Ag/AgCl wire as a sensor for determination of water soluble chloride in admixtures and aggregates for cement has been developed. A liquid sample or an extract was injected into a water carrier stream which was then merged with 0.1M KNO(3) stream and flowed through a flow cell where the solution will be in contact with the sensor, producing a potential change recorded as a peak. A calibration graph in range of 10-100 mg L(-1) was obtained with a detection limit of 2 mg L(-1). Relative standard deviations for 7 replicates injecting of 20, 60 and 90 mg L(-1) chloride solutions were 1.0, 1.2 and 0.6%, respectively. Sample throughput of 60 h(-1) was achieved with the consumption of 1 mL each of electrolyte solution and water carrier. The developed method was validated by the British Standard methods.
Diffusiophoresis in one-dimensional solute gradients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ault, Jesse T.; Warren, Patrick B.; Shin, Sangwoo
Here, the diffusiophoretic motion of suspended colloidal particles under one-dimensional solute gradients is solved using numerical and analytical techniques. Similarity solutions are developed for the injection and withdrawal dynamics of particles into semi-infinite pores. Furthermore, a method of characteristics formulation of the diffusion-free particle transport model is presented and integrated to realize particle trajectories. Analytical solutions are presented for the limit of small particle diffusiophoretic mobility Γ p relative to the solute diffusivity D s for particle motions in both semi-infinite and finite domains. Results confirm the build up of local maxima and minima in the propagating particle front dynamics.more » The method of characteristics is shown to successfully predict particle motions and the position of the particle front, although it fails to accurately predict suspended particle concentrations in the vicinity of sharp gradients, such as at the particle front peak seen in some injection cases, where particle diffusion inevitably plays an important role. Results inform the design of applications in which the use of applied solute gradients can greatly enhance particle injection into and withdrawal from pores.« less
Bures, Jan; Kopácová, Marcela; Kvetina, Jaroslav; Osterreicher, Jan; Sinkorová, Zuzana; Svoboda, Zbynek; Tachecí, Ilja; Filip, Stanislav; Spelda, Stanislav; Kunes, Martin; Rejchrt, Stanislav
2009-09-01
We hypothesised that different solutions for submucosal injection may influence early healing of endoscopic mucosal resection (EMR). The aim of this study was to evaluate histological and immunological changes after EMR in experimental pigs. Two parallel EMRs on the anterior and posterior wall of the gastric body were performed by means of the cap technique in 21 female pigs. A glycerol-based solution (anterior EMR) and hydroxypropyl methylcellulose solution (posterior EMR) were applied for submucosal injection. The animals were sacrificed 7 days later, and tissue sections of all EMRs were stained using combined trichrome. Computer image analysis was used for objective evaluation of elastic and collagen fibres content. Two-colour indirect immunophenotyping of blood and gastric samples were performed using mouse anti-pig monoclonal antibodies. The values of collagen fibre content 7 days after EMR were significantly higher in lesions after the use of solution A in comparison with solution B (2.10 +/- 0.25% versus 1.57 +/- 0.25%, p = 0.009). Concordant results were found in elastic fibres (3.23 +/- 0.49% versus 2.93 +/- 0.61%, p = 0.018). No systemic changes in major leukocyte subpopulations were found. In gastric tissue, lymphocyte subsets exhibited only minor changes. CD4(+) T-lymphocytes were increased in the healing tissue after EMR using solution A (17.08 +/- 9.24% versus 9.76 +/- 7.97%, p = 0.011). Significant increase of SWC3(+) leukocytes was observed after EMR using solution B (47.70 +/- 25.41% versus 18.70 +/- 12.16%, p = 0.001). The use of glycerol-based solution for submucosal injection was associated with more pronounced histological signs of early healing of EMRs compared with hydroxypropyl methylcellulose.
Susi, Louis; Reader, Al; Nusstein, John; Beck, Mike; Weaver, Joel; Drum, Melissa
2008-01-01
The authors, using a crossover design, randomly administered, in a single-blind manner, 3 primary intraosseous injections to 61 subjects using: the Wand local anesthetic system at a deposition rate of 45 seconds (fast injection); the Wand local anesthetic system at a deposition rate of 4 minutes and 45 seconds (slow injection); a conventional syringe injection at a deposition rate of 4 minutes and 45 seconds (slow injection), in 3 separate appointments spaced at least 3 weeks apart. A pulse oximeter measured heart rate (pulse). The results demonstrated the mean maximum heart rate was statistically higher with the fast intraosseous injection (average 21 to 28 beats/min increase) than either of the 2 slow intraosseous injections (average 10 to 12 beats/min increase). There was no statistically significant difference between the 2 slow injections. We concluded that an intraosseous injection of 1.4 mL of 2% lidocaine with 1 : 100,000 epinephrine with the Wand at a 45-second rate of anesthetic deposition resulted in a significantly higher heart rate when compared with a 4-minute and 45-second anesthetic solution deposition using either the Wand or traditional syringe. PMID:18327970
Susi, Louis; Reader, Al; Nusstein, John; Beck, Mike; Weaver, Joel; Drum, Melissa
2008-01-01
The authors, using a crossover design, randomly administered, in a single-blind manner, 3 primary intraosseous injections to 61 subjects using: the Wand local anesthetic system at a deposition rate of 45 seconds (fast injection); the Wand local anesthetic system at a deposition rate of 4 minutes and 45 seconds (slow injection); a conventional syringe injection at a deposition rate of 4 minutes and 45 seconds (slow injection), in 3 separate appointments spaced at least 3 weeks apart. A pulse oximeter measured heart rate (pulse). The results demonstrated the mean maximum heart rate was statistically higher with the fast intraosseous injection (average 21 to 28 beats/min increase) than either of the 2 slow intraosseous injections (average 10 to 12 beats/min increase). There was no statistically significant difference between the 2 slow injections. We concluded that an intraosseous injection of 1.4 mL of 2% lidocaine with 1 : 100,000 epinephrine with the Wand at a 45-second rate of anesthetic deposition resulted in a significantly higher heart rate when compared with a 4-minute and 45-second anesthetic solution deposition using either the Wand or traditional syringe.
DOT National Transportation Integrated Search
2002-01-01
Rigid pavements make up a significant percentage of highway systems in the United States and abroad. Concrete pavements provide an economical and durable solution for highway systems, because the pavements last longer and require less maintenance. Re...
Yamamoto, Yutaka; Miwa, Mitsuharu
2013-06-01
Sclerotherapy with aluminum potassium tannic acid (ALTA), which was approved in Japan for the treatment of internal hemorrhoids in July 2004 (Takano et al., Int J Colorectal Dis 21:44-51, 2006), has been widely accepted because of its effectiveness and low invasiveness. More than 200,000 patients have received ALTA injection therapy. ALTA is injected directly into 4 points of an internal hemorrhoid (4-step injection) to induce sclerosis and remission of the hemorrhoids, and consequently, resolution of symptoms such as prolapse and bleeding. The precision of the 4-step injection is considered to be a crucial determinant of the success of this therapy and the risk of complications. However, sufficient evidence has not yet been obtained concerning the diffusion and distribution of the injected drug. A pilot study visualized the real-time diffusion/distribution of the drug solution following the 4-step injection, using the ICG (indocyanine green) fluorescence technique, and an infrared camera (Photodynamic EYE; PDE, Hamamatsu Photonics K.K.).
Consideration of Preventing Local Venous Pain by Dacarbazine.
Ohtsubo, Tatsuya; Tsuji, Takumi; Umeyama, Takayo; Sudou, Miho; Komesu, Kana; Matsumoto, Minako; Yoshida, Yuya; Banno, Rie; Tomogane, Kanji; Fujita, Atsuo; Kohno, Takeyuki; Mikami, Tadashi
2017-01-01
Local venous pain caused by dacarbazine (DTIC) injection is due to its photodegradation product 5-diazoimidazole-4-carboxamide (Diazo-IC). The production of Diazo-IC can be decreased by protecting the drug from light. Furthermore, the production of Diazo-IC reportedly increases with time; however, there are no studies reporting the association between the injection preparation time and local venous pain caused by the DTIC injection. We evaluated the efficacy of the following: (1) method used to shorten the injection preparation time and (2) method used to change the diluting solution for DTIC. We found that shortening the injection preparation time tended to decrease the local venous pain expression due to DTIC, and Veen F decreased the production of Diazo-IC compared with the normal saline and 5% glucose solution. These results indicate that shortening the injection preparation time may be effective in preventing the local venous pain caused by the DTIC injection; moreover, using Veen F for DTIC may also reduce the pain.
Bhattacharya, Sisir; Parekh, Satish; Dedhiya, Mahendra
2015-01-01
The objective of this study was to determine in-use stability of ceftaroline fosamil infusion solution of concentrations up to 12 mg/mL in elastomeric home infusion system prefilled with 0.9% Sodium Chloride Injection USP or 5% Dextrose Injection USP and MINI-BAG Plus Container delivery devices prefilled with 0.9% sodium chloride injection. In-use ceftaroline fosamil infusion solution (12 mg/mL) was prepared for elastomeric home infusion systems (Homepump Eclipse, Baxter Intermate, and AccuRx Elastomeric Pump) pre-filled with either 0.9% sodium chloride injection or 5% dextrose; or Baxter MINI-BAG Plus Containers pre-filled with 0.9% Sodium Chloride Injection USP (4 mg/mL to 12 mg/mL ceftaroline fosamil in final solution). The systems were stored refrigerated for 24 hours followed by up to 6 hours of storage at room temperature. Samples were analyzed at various time points for assay and degradation product by a validated stability-indicating high-performance liquid chromatography method. In-use ceftaroline fosamil infusion solution, ranging from 4-mg/mL to a maximum of 12-mg/mL concentration, in elastomeric home infusion systems prefilled with 0.9% sodium chloride injection or 5% dextrose, and MINI-BAG Plus Containers prefilled with 0.9% sodium chloride injection were chemically stable for up to 24 hours refrigerated at 2°C to 8°C (36°F to 46°F) and up to 6 hours at room temperature and had acceptable compatibility with material used. Ceftaroline fosamil (4 mg/mL to 12 mg/mL) maintains its potency for up to 24 hours refrigerated at 2°C to 8°C (36°F to 46°F) and up to 6 hours of storage at room temperature upon reconstitution in infusion solution with 0.9% sodium chloride or 5% dextrose when used in elastomeric home infusion system and MINI-BAG Plus Containers delivery devices prefilled with 0.9% sodium chloride injection.
Replogle, K; Reader, A; Nist, R; Beck, M; Weaver, J; Meyers, W J
1999-05-01
Because a number of patients have reported an increase in heart rate with the intraosseous, or i.o., injection, it is important to evaluate changes in the cardiovascular system with this injection technique. The purpose of this study was to determine the cardiovascular effects of an i.o. injection of 2 percent lidocaine with 1:100,000 epinephrine and 3 percent mepivacaine. With the use of a repeated-measures design, the authors randomly assigned 42 subjects to receive i.o. injections of 1.8 milliliters of 2 percent lidocaine with 1:100,000 epinephrine or 1.8 mL of 3 percent mepivacaine in a double-blinded manner at two appointments. At each appointment the authors monitored electrocardiographic findings, cardiac rate, systolic and diastolic blood pressure, and mean arterial pressure before, during and after administration of anesthetic solutions. With the 2 percent lidocaine with 1:100,000 epinephrine solution, 28 (67 percent) of 42 subjects experienced an increase in heart rate that might be attributed to the effect of the epinephrine. In 22 (79 percent) of these subjects, the heart rate returned to within 5 beats of baseline values within four minutes after solution deposition. The authors found no significant increase in heart rate in subjects receiving the 3 percent mepivacaine. No significant differences (P > .05) were found in mean diastolic, mean systolic or mean arterial blood pressure values between the subjects receiving 2 percent lidocaine with 1:100,000 epinephrine and those receiving 3 percent mepivacaine. The majority of subjects receiving the i.o. injection of the 2 percent lidocaine-epinephrine solution experienced a transient increase in heart rate. No significant increase in heart rate was seen with the i.o. injection of 3 percent mepivacaine. While patients would likely notice the heart rate increase with the lidocaine-epinephrine solution, it would not be clinically significant in most healthy patients. In patients whose medical condition, drug therapies or epinephrine sensitivity suggests caution, 3 percent mepivacaine is a good alternative for i.o. injections.
Global, decaying solutions of a focusing energy-critical heat equation in R4
NASA Astrophysics Data System (ADS)
Gustafson, Stephen; Roxanas, Dimitrios
2018-05-01
We study solutions of the focusing energy-critical nonlinear heat equation ut = Δu - | u|2 u in R4. We show that solutions emanating from initial data with energy and H˙1-norm below those of the stationary solution W are global and decay to zero, via the "concentration-compactness plus rigidity" strategy of Kenig-Merle [33,34]. First, global such solutions are shown to dissipate to zero, using a refinement of the small data theory and the L2-dissipation relation. Finite-time blow-up is then ruled out using the backwards-uniqueness of Escauriaza-Seregin-Sverak [17,18] in an argument similar to that of Kenig-Koch [32] for the Navier-Stokes equations.
NASA Astrophysics Data System (ADS)
Thomann, Enrique A.; Guenther, Ronald B.
2006-02-01
Explicit formulae for the fundamental solution of the linearized time dependent Navier Stokes equations in three spatial dimensions are obtained. The linear equations considered in this paper include those used to model rigid bodies that are translating and rotating at a constant velocity. Estimates extending those obtained by Solonnikov in [23] for the fundamental solution of the time dependent Stokes equations, corresponding to zero translational and angular velocity, are established. Existence and uniqueness of solutions of these linearized problems is obtained for a class of functions that includes the classical Lebesgue spaces L p (R 3), 1 < p < ∞. Finally, the asymptotic behavior and semigroup properties of the fundamental solution are established.
Pioche, Mathieu; Lépilliez, Vincent; Déprez, Pierre; Giovannini, Marc; Caillol, Fabrice; Piessevaux, Hubert; Rivory, Jérôme; Guillaud, Olivier; Ciocîrlan, Mihai; Salmon, Damien; Lienhart, Isabelle; Lafon, Cyril; Saurin, Jean-Christophe; Ponchon, Thierry
2015-08-01
Long lasting elevation is a key factor during endoscopic submucosal dissection (ESD) and can be obtained by water jet injection of saline solution or by viscous macromolecular solutions. In a previous animal study, we assessed the Nestis Enki II system to combine jet injection and viscous solutions. In the present work, we used this combination in humans in different sites of the digestive tract. We retrospectively report all of the consecutive ESD procedures performed with jet injection of viscous solutions in four centers. Information was collected about the lesion, the procedure, the histological result, and the outcomes for the patient. In total, 45 resections were completed by six operators: five experts and one beginner with only one previous experience in human ESD. Lesions were located in the esophagus (10), the stomach (11), the duodenum (1), the colon (1) and the rectum (22). Average maximal lesion diameter was 4.8 cm (SD 2.4, range 2 - 11 cm), average lesion surface area was 19.8 cm(2) (SD 17.7, range 2.2 - 72 cm(2)), and average duration of procedure was 79.9 min (SD 50.3 min, range 19 - 225 min). ESD could be conducted while the endoscope was retroflexed at its maximum in 26 cases. Four adverse events were observed: two diminutive perforations and two delayed bleeding occurrences treated conservatively. The R0 resection rate was 91.1 %. The catheter was obstructed in six occurrences of bleeding. Endoscopic submucosal dissection using high pressure injection of viscous macromolecular solutions is safe and effective in different parts of the digestive tract. It does not impede working with the endoscope in the maximal retroflexed position.
Suszka-Świtek, Aleksandra; Ryszka, Florian; Dolińska, Barbara; Dec, Renata; Danch, Alojzy; Filipczyk, Łukasz; Wiaderkiewicz, Ryszard
2017-04-01
Although many synthetic gonadoliberin analogs have been developed, only a few of them, including buserelin, were introduced into clinical practice. Dalarelin, which differs from buserelin by just one aminoacid in the position 6 (D-Ala), is not widely used so far. Gonadotropin-releasing hormone (GnRH) analogs are used to treat many different illnesses and are available in different forms like solution for injection, nasal spray, microspheres, etc. Unfortunately, none of the above drug formulations can release the hormones for 24 h. We assumed that classical suspension could solve this problem. Two sets of experiments were performed. In the first one, buserelin and dalarelin were injected into mature female rats in two forms: suspension, in which the analogs are bounded by Zn 2+ ions and solution. The pharmacokinetic parameters and bioavailability of the analogs were calculated, based on their concentration in the plasma measured by high-performance liquid chromatography method (HPLC). In the second experiment, the hormones in two different forms were injected into superovulated immature female rats and then the concentration of Luteinizing hormone (LH), Follicle-stimulating hormone (FSH) and 17β-estradiol in the serum was measured by radioimmunological method. The Extent of Biological Availability (EBA), calculated on the base of AUC 0-∞ , showed that in the form of solution buserelin and dalarelin display, respectively, only 13 and 8 % of biological availability of their suspension counterparts. Comparing both analogs, the EBA of dalarelin was half (53 %) that of buserelin delivered in the form of solution and 83 % when they were delivered in the form of suspension. The injection of buserelin or dalarelin, in the form of solution or suspension, into superovulated female rats increased LH, FSH and estradiol concentration in the serum. However, after injection of the analogs in the form of suspension, the high concentration of LH and FSH in the serum persisted longer. Performed studies indicate that GnRH analogs in the form of suspension have higher bioavailability than their solution counterparts. It influences the effects of their action, especially in relation to LH and FSH.
Cai, Long-Fei; Zhu, Ying; Du, Guan-Sheng; Fang, Qun
2012-01-03
We described a microfluidic chip-based system capable of generating droplet array with a large scale concentration gradient by coupling flow injection gradient technique with droplet-based microfluidics. Multiple modules including sample injection, sample dispersion, gradient generation, droplet formation, mixing of sample and reagents, and online reaction within the droplets were integrated into the microchip. In the system, nanoliter-scale sample solution was automatically injected into the chip under valveless flow injection analysis mode. The sample zone was first dispersed in the microchannel to form a concentration gradient along the axial direction of the microchannel and then segmented into a linear array of droplets by immiscible oil phase. With the segmentation and protection of the oil phase, the concentration gradient profile of the sample was preserved in the droplet array with high fidelity. With a single injection of 16 nL of sample solution, an array of droplets with concentration gradient spanning 3-4 orders of magnitude could be generated. The present system was applied in the enzyme inhibition assay of β-galactosidase to preliminarily demonstrate its potential in high throughput drug screening. With a single injection of 16 nL of inhibitor solution, more than 240 in-droplet enzyme inhibition reactions with different inhibitor concentrations could be performed with an analysis time of 2.5 min. Compared with multiwell plate-based screening systems, the inhibitor consumption was reduced 1000-fold. © 2011 American Chemical Society
Hazards of Improper Dispensary: Literature Review and Report of an Accidental Chloroform Injection.
Verma, Prashant; Tordik, Patricia; Nosrat, Ali
2018-06-01
Several clear, transparent solutions are used in endodontics. Inappropriate dispensing methods can lead to accidental injection or accidental irrigation. These accidents can cause permanent tissue damage including damage to the bone, periodontium, nerves, and vasculature. This article reports on the consequences of an accidental chloroform injection. Nonsurgical retreatment of tooth #8 was planned as part of a restorative treatment plan in a 69-year-old woman. The dentist accidentally injected chloroform instead of local anesthesia because chloroform was loaded into the anesthetic syringe. The patient experienced severe pain and swelling and soft tissue necrosis and suffered permanent sensory and motor nerve damage. A review of the literature was performed on accidents caused by improper dispensary, namely accidental injections and accidental irrigations. The data were extracted and summarized. Sodium hypochlorite, chlorhexidine, formalin, formocresol, 1:1000 adrenaline, benzalkonium chloride, and lighter fuel were accidentally injected as an intraoral nerve block or as infiltration injections. Bone and soft tissue necrosis, tooth loss, and sensory nerve damage (anesthesia and paresthesia) were the most common consequences reported. Such disastrous events can be prevented by appropriate labeling and separate dispensing methods for each solution. There is a need for disseminating information on toxicity and biocompatibility of materials/solutions used in endodontics. The authors recommend training dental students and endodontic residents on immediate and long-term therapeutic management of patients when an accidental injection or accidental irrigation occurs. Copyright © 2018 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Solubilization of benomyl for xylem injection in vascular wilt disease control
Percy McWain; Garold F. Gregory; Garold F. Gregory
1971-01-01
Benomyl, in varying amounts, was solubilized in several solvents, thus allowing injection into trees for fungus disease prevention and therapy. A large amount of benomyl can be solubilized in diluted lactic acid. The resulting solution can be infinitely diluted with water without pre-cipitation. These characteristics make it the current solution of choice for our tree...
Inductively coupled plasma mass spectrometry (ICP/MS) with direct injection nebulization (DIN) was used to evaluate novel impinger solution compositions capable of capturing elemental mercury (Hgo) in EPA Method 5 type sampling. An iodine based impinger solutoin proved to be ver...
Tracer simulation study of potential solute movement in Port Royal Sound, South Carolina
Kilpatrick, F.A.; Cummings, T. Ray
1972-01-01
A tracer study was conducted in Port Royal Sound to simulate the movement and ultimate pattern of concentration of a solute continuously injected into the flow. A total of 750 pounds of Rhodamine WT dye was injected by boat during a period of 24.8 hours in a line across the Colleton River. During the following 43 days, samples of water were taken at selected points in the sound, and the concentration of dye in the samples was determined by fluorometric analysis. The data obtained in the field study were used with theoretical models to compute the ultimate pattern of concentration of nonconservative and conservative solutes for a hypothetical continuous injection at the site on the Colleton River.
Ninomiya, Asako; Terakawa, Yui; Matsuura, Nobuyuki; Ichinohe, Tatsuya; Kaneko, Yuzuru
2012-01-01
The purpose of this study was to examine how submucosal injection of a clinically relevant dose of a lidocaine hydrochloride solution containing epinephrine affects the muscle relaxant effects of rocuronium bromide. Sixteen patients scheduled for orthognathic surgery participated in this study. All patients were induced with fentanyl citrate, a target-controlled infusion of propofol and rocuronium bromide. Anesthesia was maintained by total intravenous anesthesia. After nasotracheal intubation, an infusion of rocuronium bromide was started at 7 µg/kg/min, and the infusion rate was then adjusted to maintain a train of four (TOF) ratio at 10 to 15%. The TOF ratio just prior to oral mucosal injection of a 1% lidocaine hydrochloride solution containing 10 µg/mL epinephrine (LE) was taken as the baseline. TOF ratio was observed for 20 minutes, with 1-minute intervals following the start of injection. Mean epinephrine dose was 85.6 ± 18.6 µg and mean infusion rate of rocuronium bromide was 6.3 ± 1.6 µg/kg/min. TOF ratio began to decrease 2 minutes after the injection of LE, reached the minimum value at 3.1 ± 3.6% 12 minutes after the injection, and then began to recover. We conclude that oral mucosal injection of LE enhances the muscle relaxant effects of rocuronium bromide. PMID:22428970
NASA Technical Reports Server (NTRS)
Garrett, L. B.
1971-01-01
An implicit finite difference scheme is developed for the fully coupled solution of the viscous radiating stagnation line equations, including strong blowing. Solutions are presented for both air injection and carbon phenolic ablation products injection into air at conditions near the peak radiative heating point in an earth entry trajectory from interplanetary return missions. A detailed radiative transport code that accounts for the important radiative exchange processes for gaseous mixtures in local thermodynamic and chemical equilibrium is utilized.
2015-04-01
pediatric TBI patients.36,37 The albumin solution used in this rabbit study was a 5% human albumin (Albminar) in an isotonic solution ( normal saline ... reconstituted easily at the point of injury and injected . Hemostatic properties and bene- fits of FDP or sprayed-dried plasma have been demonstrated...rabbit albumin solution appro- priate for intravenous injection is not commercially available. Rabbit albumin is sold by chemical companies as
NASA Astrophysics Data System (ADS)
Chen, Li-Chieh; Huang, Mei-Jiau
2017-02-01
A 2D simulation method for a rigid body moving in an incompressible viscous fluid is proposed. It combines one of the immersed-boundary methods, the DFFD (direct forcing fictitious domain) method with the spectral element method; the former is employed for efficiently capturing the two-way FSI (fluid-structure interaction) and the geometric flexibility of the latter is utilized for any possibly co-existing stationary and complicated solid or flow boundary. A pseudo body force is imposed within the solid domain to enforce the rigid body motion and a Lagrangian mesh composed of triangular elements is employed for tracing the rigid body. In particular, a so called sub-cell scheme is proposed to smooth the discontinuity at the fluid-solid interface and to execute integrations involving Eulerian variables over the moving-solid domain. The accuracy of the proposed method is verified through an observed agreement of the simulation results of some typical flows with analytical solutions or existing literatures.
Self Assembled Bi-functional Peptide Hydrogels with Biomineralization-Directing Peptides
Gungormus, Mustafa; Branco, Monica; Fong, Hanson; Schneider, Joel P.; Tamerler, Candan; Sarikaya, Mehmet
2014-01-01
A peptide-based hydrogel has been designed that directs the formation of hydroxyapatite. MDG1, a twenty-seven residue peptide, undergoes triggered folding to form an unsymmetrical β-hairpin that self-assembles in response to an increase in solution ionic strength to yield a mechanically rigid, self supporting hydrogel. The C-terminal portion of MDG1 contains a heptapeptide (MLPHHGA) capable of directing the mineralization process. Circular dichroism spectroscopy indicates that the peptide folds and assembles to form a hydrogel network rich in β-sheet secondary structure. Oscillatory rheology indicates that the hydrogel is mechanical rigid (G′ ∼ 2500 Pa) before mineralization. In separate experiments, mineralization was induced both biochemically and with cementoblast cells. Mineralization-domain had little effect on the mechanical rigidity of the gel. SEM and EDS show that MDG1 gels are capable of directing the formation of hydroxapatite. Control hydrogels, prepared by peptides either lacking the mineral-directing portion or reversing its sequence, indicated that the heptapeptide is necessary and its actions are sequence specific. PMID:20591477
Efficient vibration mode analysis of aircraft with multiple external store configurations
NASA Technical Reports Server (NTRS)
Karpel, M.
1988-01-01
A coupling method for efficient vibration mode analysis of aircraft with multiple external store configurations is presented. A set of low-frequency vibration modes, including rigid-body modes, represent the aircraft. Each external store is represented by its vibration modes with clamped boundary conditions, and by its rigid-body inertial properties. The aircraft modes are obtained from a finite-element model loaded by dummy rigid external stores with fictitious masses. The coupling procedure unloads the dummy stores and loads the actual stores instead. The analytical development is presented, the effects of the fictitious mass magnitudes are discussed, and a numerical example is given for a combat aircraft with external wing stores. Comparison with vibration modes obtained by a direct (full-size) eigensolution shows very accurate coupling results. Once the aircraft and stores data bases are constructed, the computer time for analyzing any external store configuration is two to three orders of magnitude less than that of a direct solution.
Establishment of a biomimetic device based on tri-layer polymer actuators--propulsion fins.
Alici, Gursel; Spinks, Geoffrey; Huynh, Nam N; Sarmadi, Laleh; Minato, Rick
2007-06-01
We propose to use bending type tri-layer polymer actuators as propulsion fins for a biomimetic device consisting of a rigid body, like a box fish having a carapace, and paired fins running through the rigid body, like a fish having pectoral fins. The fins or polymer bending actuators can be considered as individually controlled flexible membranes. Each fin is activated with sinusoidal inputs such that there is a phase lag between the movements of successive fins to create enough thrust force for propulsion. Eight fins with 0.125 aspect ratio have been used along both sides of the rigid body to move the device in the direction perpendicular to the longitudinal axis of the body. The designed device with the paired fins was successfully tested, moving in an organic solution consisting of solvent, propylene carbonate (PC), and electrolyte. The design procedure outlined in this study is offered as a guide to making functional devices based on polymer actuators and sensors.
NASA Technical Reports Server (NTRS)
Chen, J. C.; Garba, J. A.; Wada, B. K.
1978-01-01
In the design/analysis process of a payload structural system, the accelerations at the payload/launch vehicle interface obtained from a system analysis using a rigid payload are often used as the input forcing function to the elastic payload to obtain structural design loads. Such an analysis is at best an approximation since the elastic coupling effects are neglected. This paper develops a method wherein the launch vehicle/rigid payload interface accelerations are modified to account for the payload elasticity. The advantage of the proposed method, which is exact to the extent that the physical system can be described by a truncated set of generalized coordinates, is that the complete design/analysis process can be performed within the organization responsible for the payload design. The method requires the updating of the system normal modes to account for payload changes, but does not require a complete transient solution using the composite system model. An application to a real complex structure, the Viking Spacecraft System, is given.
[Fabrication and Performance Study of Polydimethylsiloxane Intraocular Lens].
Du, Qiuyue; Yu, Yueqing
2016-10-01
To simplify the production process of intraocular lens(IOL)and to solve the problem of lacking adjustable ability,we proposed a novel soft IOL with large-scale adjustable ability and rigid haptics based on heat-assisted method,and gravity-assisted method.Polydimethylsiloxane(PDMS)and rigid material--polymethyl methacrylate(PMMA)were used as the materials for fabricating optical lens(PDMS)and haptics(PDMS and PMMA)through changing the weight ratio of the solution.A lens-smartphone microscopy system was established to replace the traditional digital microscopy to measure the tiny displacements and shape changes.The PDMS lens has excellent optical property through an experiment in which the maximum optical power was around 273.2D.Experimental results indicated that the maximum optical power of PMMA IOL was 129.3D,and that in PDMS IOL,however,was only 56.0D.Thus,the rigid PMMA-IOL has a larger adjustable range.The production process of PDMS was mold-free,rapid,real-time,and highly repeatable and there was no need for a rigorous experimental environment either.This creative processing technology reduced the manufacturing steps from which an optical lens with high transmittance and high resolution,as well as hatics with accurate dimensions,were obtained.The rigidity of haptics affected more intensely than other factors did for improving the pre-displacement and changing the appearance of PDMS lens.Even though the rigidity of PMMA haptics is large enough for accommodating,there are many drawbacks during manufacturing.It is unavailable to rapid fabricate IOL using PMMA.Thus,further work will be required to alter the weight ratio of PDMS material,increase the rigidity,and enhance the adjustable ability of PDMS IOL.
Inoue, Naoto; Takai, Eisuke; Arakawa, Tsutomu; Shiraki, Kentaro
2014-05-01
Therapeutic protein solutions for subcutaneous injection must be very highly concentrated, which increases their viscosity through protein-protein interactions. However, maintaining a solution viscosity below 50 cP is important for the preparation and injection of therapeutic protein solutions. In this study, we examined the effect of various amino acids on the solution viscosity of very highly concentrated bovine serum albumin (BSA) and human serum albumin (HSA) at a physiological pH. Among the amino acids tested, l-arginine hydrochloride (ArgHCl) and l-lysine hydrochloride (LysHCl) (50-200 mM) successfully reduced the viscosity of both BSA and HSA solutions; guanidine hydrochloride (GdnHCl), NaCl, and other sodium salts were equally as effective, indicating the electrostatic shielding effect of these additives. Fourier transform infrared spectroscopy showed that BSA is in its native state even in the presence of ArgHCl, LysHCl, and NaCl at high protein concentrations. These results indicate that weakened protein-protein interactions play a key role in reducing solution viscosity. ArgHCl and LysHCl, which are also non-toxic compounds, will be used as additives to reduce the solution viscosity of concentrated therapeutic proteins. Copyright © 2013 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.
Low HAP/VOC Compliant Resins for Military Applications
2011-09-01
of such resins are poor. Various solutions have been proposed over the years, but most suffer from a number of drawbacks that have prevented their...tip-over involved tipping the container onto its sides. The impact test involved swinging the container as a pendulum into a rigid wall. The
Ambiguities of a Motion Field.
1987-01-01
solutions in the case of planar surfaces has since been reported by Tsai et al. 11982], Waxman & Ullman [19851, Longuet-Higgins [1984], Maybank [1984], and... Maybank , SiJ. (1984) "The Angular Velocity Associated with the Optical Flow Field due to a Single Moving Rigid Plane,’ Proceedings of the Stzth European
Computing the Free Energy along a Reaction Coordinate Using Rigid Body Dynamics.
Tao, Peng; Sodt, Alexander J; Shao, Yihan; König, Gerhard; Brooks, Bernard R
2014-10-14
The calculations of potential of mean force along complex chemical reactions or rare events pathways are of great interest because of their importance for many areas in chemistry, molecular biology, and material science. The major difficulty for free energy calculations comes from the great computational cost for adequate sampling of the system in high-energy regions, especially close to the reaction transition state. Here, we present a method, called FEG-RBD, in which the free energy gradients were obtained from rigid body dynamics simulations. Then the free energy gradients were integrated along a reference reaction pathway to calculate free energy profiles. In a given system, the reaction coordinates defining a subset of atoms (e.g., a solute, or the quantum mechanics (QM) region of a quantum mechanics/molecular mechanics simulation) are selected to form a rigid body during the simulation. The first-order derivatives (gradients) of the free energy with respect to the reaction coordinates are obtained through the integration of constraint forces within the rigid body. Each structure along the reference reaction path is separately subjected to such a rigid body simulation. The individual free energy gradients are integrated along the reference pathway to obtain the free energy profile. Test cases provided demonstrate both the strengths and weaknesses of the FEG-RBD method. The most significant benefit of this method comes from the fast convergence rate of the free energy gradient using rigid-body constraints instead of restraints. A correction to the free energy due to approximate relaxation of the rigid-body constraint is estimated and discussed. A comparison with umbrella sampling using a simple test case revealed the improved sampling efficiency of FEG-RBD by a factor of 4 on average. The enhanced efficiency makes this method effective for calculating the free energy of complex chemical reactions when the reaction coordinate can be unambiguously defined by a small subset of atoms within the system.
Computing the Free Energy along a Reaction Coordinate Using Rigid Body Dynamics
2015-01-01
The calculations of potential of mean force along complex chemical reactions or rare events pathways are of great interest because of their importance for many areas in chemistry, molecular biology, and material science. The major difficulty for free energy calculations comes from the great computational cost for adequate sampling of the system in high-energy regions, especially close to the reaction transition state. Here, we present a method, called FEG-RBD, in which the free energy gradients were obtained from rigid body dynamics simulations. Then the free energy gradients were integrated along a reference reaction pathway to calculate free energy profiles. In a given system, the reaction coordinates defining a subset of atoms (e.g., a solute, or the quantum mechanics (QM) region of a quantum mechanics/molecular mechanics simulation) are selected to form a rigid body during the simulation. The first-order derivatives (gradients) of the free energy with respect to the reaction coordinates are obtained through the integration of constraint forces within the rigid body. Each structure along the reference reaction path is separately subjected to such a rigid body simulation. The individual free energy gradients are integrated along the reference pathway to obtain the free energy profile. Test cases provided demonstrate both the strengths and weaknesses of the FEG-RBD method. The most significant benefit of this method comes from the fast convergence rate of the free energy gradient using rigid-body constraints instead of restraints. A correction to the free energy due to approximate relaxation of the rigid-body constraint is estimated and discussed. A comparison with umbrella sampling using a simple test case revealed the improved sampling efficiency of FEG-RBD by a factor of 4 on average. The enhanced efficiency makes this method effective for calculating the free energy of complex chemical reactions when the reaction coordinate can be unambiguously defined by a small subset of atoms within the system. PMID:25328492
Torque balance, Taylor's constraint and torsional oscillations in a numerical model of the geodynamo
NASA Astrophysics Data System (ADS)
Dumberry, Mathieu; Bloxham, Jeremy
2003-11-01
Theoretical considerations and observations suggest that, to a first approximation, the Earth's dynamo is in a quasi-Taylor state, where the axial Lorentz torque on cylindrical surfaces co-axial with the rotation axis vanishes, except for the part involved in torsional oscillations. The latter are rigid azimuthal accelerations of cylindrical surfaces which oscillate with typical periods of decades. We present a solution of a numerical model of the geodynamo in which rigid accelerations of cylinder surfaces are observed. The underlying dynamic state in the model is not a Taylor state because the Reynolds stresses and viscous torque remain large and provide an effective way to balance a large Lorentz torque. This is a consequence of the limited parameter regime which can be attained numerically. Nevertheless, departures in the torque equilibrium are primarily counterbalanced by rigid accelerations of cylindrical surfaces, which, in turn, excite rigid azimuthal oscillations of the surfaces. We show that the azimuthal motion is indeed quasi-rigid, though the torsional oscillations that are produced in the model probably differ from those in the Earth's core because of the large influence of the Reynolds stresses on their dynamics. We also show that the continual excitation of rigid cylindrical accelerations is produced by the advection of the non-axisymmetric structure of the fields by a mean differential rotation of the cylindrical surfaces which produces disconnections and reconnections and continual fluctuations in the Lorentz torque and Reynolds stresses. We propose that the torque balance in Earth's core may evolve in a similar chaotic fashion, except that the influence of the Reynolds stresses is probably weaker. If this is the case, the Lorentz torque on a cylindrical surface is continually fluctuating, even though its time-averaged value vanishes and satisfies Taylor's constraint. Rigid accelerations of cylindrical surfaces are continually excited by the fluctuations in the Lorentz torque, and the torsional oscillations observed in the geomagnetic data are a mixture of forced and free oscillations.
NASA Astrophysics Data System (ADS)
Sethi, M.; Sharma, A.; Vasishth, A.
2017-05-01
The present paper deals with the mathematical modeling of the propagation of torsional surface waves in a non-homogeneous transverse isotropic elastic half-space under a rigid layer. Both rigidities and density of the half-space are assumed to vary inversely linearly with depth. Separation of variable method has been used to get the analytical solutions for the dispersion equation of the torsional surface waves. Also, the effects of nonhomogeneities on the phase velocity of torsional surface waves have been shown graphically. Also, dispersion equations have been derived for some particular cases, which are in complete agreement with some classical results.
Low-Altitude Exploration of the Venus Atmosphere by Balloon
NASA Technical Reports Server (NTRS)
Landis, Geoffrey A.
2010-01-01
The planet Venus represents an exciting target for future exploration by spacecraft. One target of scientific interest is the lower atmosphere, which represents an environment of high temperature and moderate to high atmospheric pressure. This represents a considerable challenge to the technical art of ballooning, but one which may be amenable to solution. Several possible designs for low-altitude balloons are discussed. Conceptual design for three mission examples are analyzed: a conventional balloon operating below the cloud level at an altitude of 25 kilometers, a large rigid-envelope balloon operating near the surface at an altitude of 5 kilometers, and a small, technology demonstrator rigid-envelope balloon operating at 5 kilometers.
A physical approach to the numerical treatment of boundaries in gas dynamics
NASA Technical Reports Server (NTRS)
Moretti, G.
1981-01-01
Two types of boundaries are considered: rigid walls, and artificial (open) boundaries which were arbitrarily drawn somewhere across a wider flow field. A set of partial differential equations (typically, the Euler equations) has an infinite number of solutions, each one defined by a set of initial and boundary conditions. The initial conditions remaining the same, any change in the boundary conditions will produce a new solution. To pose the problem well, a necessary and sufficient number of boundary conditions are prescribed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
In this study, IBACOS, in collaboration with GreenHomes America, Inc., was contracted by the New York State Energy Research and Development Authority (NYSERDA) to research exterior wall insulation solutions for enclosure upgrades. This case study describes the deep energy retrofit of three test homes in the Syracuse, New York area and represent these enclosure strategies: rigid foam insulation; spray foam insulation, and a control house that follows Home Performance with ENERGY STAR (HPwES) guidelines.
Solution of the Bagley Torvik equation by fractional DTM
NASA Astrophysics Data System (ADS)
Arora, Geeta; Pratiksha
2017-07-01
In this paper, fractional differential transform method(DTM) is implemented on the Bagley Torvik equation. This equation models the viscoelastic behavior of geological strata, metals, glasses etc. It explains the motion of a rigid plate immersed in a Newtonian fluid. DTM is a simple, reliable and efficient method that gives a series solution. Caputo fractional derivative is considered throughout this work. Two examples are given to demonstrate the validity and applicability of the method and comparison is made with the existing results.
6-hydroxydopamine and aggression in cats.
Beleslin, D B; Samardzić, R; Stefanović-Denić, K
1981-01-01
The effect of 6-hydroxydopamine (6-OHDA) injected into the cerebral ventricles on behaviour of singly- and group-housed cats was investigated. 6-OHDA in doses of 0.5, 1 and 2 mg was administered every morning for 5 to 8 days. In small doses 6-OHDA in singly- and group-housed cats evoked motor phenomena such as tremor, ataxia, rigidity, weakness and sometimes clonic-tonic convulsions. Occasionally restlessness, irritability and rage were observed. Large doses of 6-OHDA in group-housed cats, after a short latent period (2-3 days) produced aggression which intensified on subsequent injections, and thereafter, on repeated administrations, no longer occurred. The aggression consisted of restlessness, irritability, anger, rage, apprehension, threat, attack, fighting, flight and crying. Of autonomic phenomena mydriasis, dyspnea and sometimes piloerection were observed. The aggression was initiated by the most restless cat, or by disturbing the animals, such as by moving the cage. When 6-OHDA no longer produced aggressive behaviour, motor changes such as tremor, ataxia, rigidity, walking on broad base, weakness with adynamia and clonic-tonic convulsions developed. These latter symptoms were produced by large doses of 6-OHDA in singly-housed cats. In these animals spontaneous signs of aggressive behaviour usually were not observed, although if handled they showed rage, snarling and hissing. When singly-housed cats were kept in the same cage with group-housed animals, the singly-housed cats usually became aggressive. It appears that hyperactivity induced aggression in 6-OHDA-treated cats.
Compaction of quasi-one-dimensional elastoplastic materials.
Shaebani, M Reza; Najafi, Javad; Farnudi, Ali; Bonn, Daniel; Habibi, Mehdi
2017-06-06
Insight into crumpling or compaction of one-dimensional objects is important for understanding biopolymer packaging and designing innovative technological devices. By compacting various types of wires in rigid confinements and characterizing the morphology of the resulting crumpled structures, here, we report how friction, plasticity and torsion enhance disorder, leading to a transition from coiled to folded morphologies. In the latter case, where folding dominates the crumpling process, we find that reducing the relative wire thickness counter-intuitively causes the maximum packing density to decrease. The segment size distribution gradually becomes more asymmetric during compaction, reflecting an increase of spatial correlations. We introduce a self-avoiding random walk model and verify that the cumulative injected wire length follows a universal dependence on segment size, allowing for the prediction of the efficiency of compaction as a function of material properties, container size and injection force.
Iwasaki, Koji; Sudo, Hideki; Kasahara, Yasuhiko; Yamada, Katsuhisa; Ohnishi, Takashi; Tsujimoto, Takeru; Iwasaki, Norimasa
2016-10-01
To determine the in vivo effects of multiple local anesthetic injections of 0.5% bupivacaine on normal and osteoarthritic articular cartilage. Rats with normal knee joints received an intra-articular injection of 0.9% saline solution or 0.5% bupivacaine in their right knees joint once a week for 5 consecutive weeks, starting 4 weeks after the beginning of the experiment. Rats were humanely killed at 8, 16, and 24 weeks. In a parallel experiment, rats underwent anterior cruciate ligament transection to induce osteoarthritic changes. These rats were subjected to the same protocol as those with normal knee joints, starting 4 weeks after the procedure. Static weight-bearing tests were performed on both hind limbs to evaluate changes in weight-bearing ability throughout the experiments. Rats were humanely killed at 8 and 16 weeks. Cell viability was assessed with confocal microscopy, using samples from the distal femur. Histologic assessment of osteoarthritis was performed using samples from the tibial plateau based on the Osteoarthritis Research Society International (OARSI) cartilage histopathology assessment system (i.e., OARSI score). Static weight-bearing tests showed no significant changes after intra-articular injection of saline solution or bupivacaine, and bupivacaine injection did not increase weight bearing compared with saline solution injection, regardless of whether there were osteoarthritic changes. There were also no significant differences in cell viability, cell density, or OARSI scores between the saline solution and bupivacaine groups at each time point, regardless of whether osteoarthritic changes were induced. This study suggested that single or intermittent intra-articular bupivacaine injections might not have deleterious effects on either osteoarthritic or normal joints. There is no strong evidence that intra-articular bupivacaine injection induces degenerative changes in articular cartilage. Therefore, these results may apply to normal and osteoarthritic joints. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
YAMAZAKI, Kendi; MALUF-FILHO, Fauze; da COSTA, Vitor Alves Pessoa; PESSORRUSSO, Fernanda Cristina Simões; HONDO, Fabio Yuji; SAKAI, Paulo; de FIGUEIREDO, Luis Francisco Poli
2015-01-01
Background : Endoscopic submucosal dissection carries an increased risk of bleeding and perforation. The creation of a long lasting submucosal cushion is essential for the safe and complete removal of the lesion. There is not a suitable experimental model for evaluation of the durability of the cushioning effect of different solutions. Aim : To describe an improved experimental model to evaluate submucosal injection solutions. Methods : A total of four domestic pigs were employed to evaluate two different submucosal fluid solutions in the gastric submucosa. After midline laparotomy, the anterior gastric wall was incised from the gastric body to the antrum and its mucosal surface was exposed by flipping inside out the incised gastric wall. Two different solutions (10% mannitol and normal saline) were injected in the submucosa of the anterior wall of the distal gastric body. All submucosal cushions were injected until they reach the same size, standardized as 1.0 cm in height and 2.0 cm in diameter. A caliper and a ruler were employed to guarantee accuracy of the measurements. Results : All four animal experiments were completed. All submucosal cushions had the exact same size measured with caliper and a ruler. By using the mannitol solution, the mean duration of the submucosal cushion was longer than the saline solution: 20 and 22 min (mean, 21 min) vs 5 and 6 min (mean, 5.5 min) Conclusions : This experimental model is simple and evaluate the duration, size, and effect of the submucosal cushion, making it more reliable than other models that employ resected porcine stomachs or endoscopic images in live porcine models. PMID:26734797
Yamazaki, Kendi; Maluf-Filho, Fauze; da Costa, Vitor Alves Pessoa; Pessorrusso, Fernanda Cristina Simões; Hondo, Fabio Yuji; Sakai, Paulo; de Figueiredo, Luis Francisco Poli
2015-01-01
Endoscopic submucosal dissection carries an increased risk of bleeding and perforation. The creation of a long lasting submucosal cushion is essential for the safe and complete removal of the lesion. There is not a suitable experimental model for evaluation of the durability of the cushioning effect of different solutions. To describe an improved experimental model to evaluate submucosal injection solutions. A total of four domestic pigs were employed to evaluate two different submucosal fluid solutions in the gastric submucosa. After midline laparotomy, the anterior gastric wall was incised from the gastric body to the antrum and its mucosal surface was exposed by flipping inside out the incised gastric wall. Two different solutions (10% mannitol and normal saline) were injected in the submucosa of the anterior wall of the distal gastric body. All submucosal cushions were injected until they reach the same size, standardized as 1.0 cm in height and 2.0 cm in diameter. A caliper and a ruler were employed to guarantee accuracy of the measurements. All four animal experiments were completed. All submucosal cushions had the exact same size measured with caliper and a ruler. By using the mannitol solution, the mean duration of the submucosal cushion was longer than the saline solution: 20 and 22 min (mean, 21 min) vs 5 and 6 min (mean, 5.5 min) This experimental model is simple and evaluate the duration, size, and effect of the submucosal cushion, making it more reliable than other models that employ resected porcine stomachs or endoscopic images in live porcine models.
Ptachcinski, R J; Logue, L W; Burckart, G J; Venkataramanan, R
1986-01-01
The stability of cyclosporine in commonly used i.v. solutions and the percentage of the drug delivered via polyvinyl chloride administration tubing were studied. Cyclosporine injection was prepared according to the manufacturer's instructions and diluted with 5% dextrose injection (D5W) or with 0.9% sodium chloride injection (NS). Admixtures containing cyclosporine 2 mg/mL were prepared in polyvinyl chloride minibags (five for each solution) and in glass containers (three for each solution). The sample obtained at time zero from a glass container protected from light was the control. Additional samples were prepared in minibags and run through 70-inch polyvinyl chloride administration sets. An HPLC assay for cyclosporine was used. Exposure to room light did not significantly affect cyclosporine concentrations. More than 90% of the initial drug concentration remained after 24 hours under all storage conditions, but less than 95% remained after 6 hours in samples diluted with NS and stored in plastic. At times up to 60 minutes, cyclosporine concentrations were significantly different in solutions infused from the minibags through polyvinyl chloride tubing from those in control solutions. Under these conditions, cyclosporine is stable in D5W in glass containers or polyvinyl chloride minibags for 24 hours and in NS for 6 hours (polyvinyl chloride) to 12 hours (glass). However, because of the potential for leaching of plasticizers, cyclosporine admixtures should be stored in glass or used within six hours if stored in polyvinyl chloride minibags. Approximately 10% of the initial drug concentration is lost to 70-inch length polyvinyl chloride infusion tubing.
Simulation of ground-water flow and solute transport in the Glen Canyon aquifer, East-Central Utah
Freethey, Geoffrey W.; Stolp, Bernard J.
2010-01-01
The extraction of methane from coal beds in the Ferron coal trend in central Utah started in the mid-1980s. Beginning in 1994, water from the extraction process was pressure injected into the Glen Canyon aquifer. The lateral extent of the aquifer that could be affected by injection is about 7,600 square miles. To address regional-scale effects of injection over a decadal time frame, a conceptual model of ground-water movement and transport of dissolved solids was formulated. A numerical model that incorporates aquifer concepts was then constructed and used to simulate injection.The Glen Canyon aquifer within the study area is conceptualized in two parts—an active area of ground-water flow and solute transport that exists between recharge areas in the San Rafael Swell and Desert, Waterpocket Fold, and Henry Mountains and discharge locations along the Muddy, Dirty Devil, San Rafael, and Green Rivers. An area of little or negligible ground-water flow exists north of Price, Utah, and beneath the Wasatch Plateau. Pressurized injection of coal-bed methane production water occurs in this area where dissolved-solids concentrations can be more than 100,000 milligrams per liter. Injection has the potential to increase hydrologic interaction with the active flow area, where dissolved-solids concentrations are generally less than 3,000 milligrams per liter.Pressurized injection of coal-bed methane production water in 1994 initiated a net addition of flow and mass of solutes into the Glen Canyon aquifer. To better understand the regional scale hydrologic interaction between the two areas of the Glen Canyon aquifer, pressurized injection was numerically simulated. Data constraints precluded development of a fully calibrated simulation; instead, an uncalibrated model was constructed that is a plausible representation of the conceptual flow and solute-transport processes. The amount of injected water over the 36-year simulation period is about 25,000 acre-feet. As a result, simulated water levels in the injection areas increased by 50 feet and dissolved-solids concentrations increased by 100 milligrams per liter or more. These increases are accrued into aquifer storage and do not extend to the rivers during the 36-year simulation period. The amount of change in simulated discharge and solute load to the rivers is less than the resolution accuracy of the numerical simulation and is interpreted as no significant change over the considered time period.
Salis, Andrea; Rassu, Giovanna; Budai-Szűcs, Maria; Benzoni, Ilaria; Csányi, Erzsébet; Berkó, Szilvia; Maestri, Marcello; Dionigi, Paolo; Porcu, Elena P; Gavini, Elisabetta; Giunchedi, Paolo
2015-01-01
Thermosensitive chitosan/glycerophosphate (C/GP) solutions exhibiting sol-gel transition around body temperature were prepared to develop a class of injectable hydrogel platforms for the imaging and loco-regional treatment of hepatocellular carcinoma (HCC). Indocyanine green (ICG) was loaded in the thermosensitive solutions in order to assess their potential for the detection of tumor nodules by fluorescence. The gel formation of these formulations as well as their gelling time, injectability, compactness and resistance of gel structure, gelling temperature, storage conditions, biodegradability, and in vitro dye release behavior were investigated. Ex vivo studies were carried out for preliminary evaluation using an isolated bovine liver. Gel strengths and gelation rates increased with the cross-link density between C and GP. These behaviors are more evident for C/GP solutions, which displayed a gel-like precipitation at 4°C. Furthermore, formulations with the lowest cross-link density between C and GP exhibited the best injectability due to a lower resistance to flow. The loading of the dye did not influence the gelation rate. ICG was not released from the hydrogels because of a strong electrostatic interaction between C and ICG. Ex vivo preliminary studies revealed that these injectable formulations remain in correspondence of the injected site. The developed ICG-loaded hydrogels have the potential for intraoperative fluorescence imaging and local therapy of HCC as embolic agents. They form in situ compact gels and have a good potential for filling vessels and/or body cavities.
Fang, Qingling; Kim, Dong-Pyo; Li, Xiaodong; Yoon, Tae-Ho; Li, Yihe
2011-08-21
Highly effective mixing in microchannels is important for most chemical reactions conducted in microfluidic chips. To obtain a rigid and chemically resistant micromixer system at low cost, we fabricated a Y-shaped microchannel with built-in mixer structures by static liquid photolithography (SLP) from methacrylated polyvinylsilazane (MPVSZ) as an inorganic polymer photoresist which was then converted to a silicate phase by hydrolysis in vaporized ammonia atmosphere at 80 °C. The microchannel incorporating herringbone mixer structures was bonded with a matching polydimethylsiloxane (PDMS) open channel which was pre-coated by perhydropolysilazane (PHPS)-based mixture, and finally treated by additional hydrolysis at room temperature to convert the PHPS layer to a silica phase. Finally, the chemical resistance of the microfluidic system with embedded micromixer was confirmed with various solvents, and the excellent mixing performance in a short mixing length of 2.3 cm was demonstrated by injecting two different colored fluids into the microchannel. This journal is © The Royal Society of Chemistry 2011
Heidari, M R; Foroumadi, A; Amirabadi, A; Samzadeh-Kermani, A; Azimzadeh, B S; Eskandarizadeh, A
2009-08-01
There have been many reports indicating the analgesic and anti-inflammatory effects of 3,4-dihydroxychalcones. We have designed and synthesized a rigid 3,4-dihydroxychalcone (RDHC) as a possible drug effecting inflammation and nociception. The analgesic and anti-inflammatory effects were evaluated by formalin and hot-plate tests, respectively. The results showed that RDHC induced significant antinociceptive and anti-inflammatory effects (P < 0.01). Maximum analgesia (63.7%) was observed at 37.5 mg/kg in the first phase of the formalin test. The effect of RDHC was higher in the chronic phase (inflammation phase) of the formalin test (86.4%, P < 0.01). In addition, a significant analgesia (maximum possible effect; MPE = 30.1%) was observed in the hot plate test 45 min after injection of 37.5 mg/kg RDHC (P < 0.01). As a result of our findings, this new RDHC could be suggested for further pharmacological studies.
Lightweight bipolar storage battery
NASA Technical Reports Server (NTRS)
Rowlette, John J. (Inventor)
1992-01-01
An apparatus [10] is disclosed for a lightweight bipolar battery of the end-plate cell stack design. Current flow through a bipolar cell stack [12] is collected by a pair of copper end-plates [16a,16b] and transferred edgewise out of the battery by a pair of lightweight, low resistance copper terminals [28a,28b]. The copper terminals parallel the surface of a corresponding copper end-plate [16a,16b] to maximize battery throughput. The bipolar cell stack [12], copper end-plates [16a,16b] and copper terminals [28a,28b] are rigidly sandwiched between a pair of nonconductive rigid end-plates [20] having a lightweight fiber honeycomb core which eliminates distortion of individual plates within the bipolar cell stack due to internal pressures. Insulating foam [30] is injected into the fiber honeycomb core to reduce heat transfer into and out of the bipolar cell stack and to maintain uniform cell performance. A sealed battery enclosure [ 22] exposes a pair of terminal ends [26a,26b] for connection with an external circuit.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mitri, F. G., E-mail: F.G.Mitri@ieee.org
2015-11-14
Using the partial-wave series expansion method in cylindrical coordinates, a formal analytical solution for the acoustical scattering of a 2D cylindrical quasi-Gaussian beam with an arbitrary angle of incidence θ{sub i}, focused on a rigid elliptical cylinder in a non-viscous fluid, is developed. The cylindrical focused beam expression is an exact solution of the Helmholtz equation. The scattering coefficients for the elliptical cylinder are determined by forcing the expression of the total (incident + scattered) field to satisfy the Neumann boundary condition for a rigid immovable surface, and performing the product of matrices involving an inversion procedure. Computations for the matrices elementsmore » require a single numerical integration procedure for each partial-wave mode. Numerical results are performed with particular emphasis on the focusing properties of the incident beam and its angle of incidence with respect to the major axis a of the ellipse as well as the aspect ratio a/b where b is the minor axis (assuming a > b). The method is validated and verified against previous results obtained via the T-matrix for plane waves. The present analysis is the first to consider an acoustical beam on an elliptic cylinder of variable cross-section as opposed to plane waves of infinite extent. Other 2D non-spherical and Chebyshev surfaces are mentioned that may be examined throughout this analytical formalism assuming a small deformation parameter ε.« less
Numerical integration and optimization of motions for multibody dynamic systems
NASA Astrophysics Data System (ADS)
Aguilar Mayans, Joan
This thesis considers the optimization and simulation of motions involving rigid body systems. It does so in three distinct parts, with the following topics: optimization and analysis of human high-diving motions, efficient numerical integration of rigid body dynamics with contacts, and motion optimization of a two-link robot arm using Finite-Time Lyapunov Analysis. The first part introduces the concept of eigenpostures, which we use to simulate and analyze human high-diving motions. Eigenpostures are used in two different ways: first, to reduce the complexity of the optimal control problem that we solve to obtain such motions, and second, to generate an eigenposture space to which we map existing real world motions to better analyze them. The benefits of using eigenpostures are showcased through different examples. The second part reviews an extensive list of integration algorithms used for the integration of rigid body dynamics. We analyze the accuracy and stability of the different integrators in the three-dimensional space and the rotation space SO(3). Integrators with an accuracy higher than first order perform more efficiently than integrators with first order accuracy, even in the presence of contacts. The third part uses Finite-time Lyapunov Analysis to optimize motions for a two-link robot arm. Finite-Time Lyapunov Analysis diagnoses the presence of time-scale separation in the dynamics of the optimized motion and provides the information and methodology for obtaining an accurate approximation to the optimal solution, avoiding the complications that timescale separation causes for alternative solution methods.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Takayama, Yuki; Schwieters, Charles D.; Grishaev, Alexander
2012-10-23
The first component of the bacterial phosphotransferase system, enzyme I (EI), is a multidomain 128 kDa dimer that undergoes large rigid-body conformational transitions during the course of its catalytic cycle. Here we investigate the solution structure of a non-phosphorylatable active-site mutant in which the active-site histidine is substituted by glutamine. We show that perturbations in the relative orientations and positions of the domains and subdomains can be rapidly and reliably determined by conjoined rigid-body/torsion angle/Cartesian simulated annealing calculations driven by orientational restraints from residual dipolar couplings and shape and translation information afforded by small- and wide-angle X-ray scattering. Although histidinemore » and glutamine are isosteric, the conformational space available to a Gln side chain is larger than that for the imidazole ring of His. An additional hydrogen bond between the side chain of Gln189 located on the EIN{sup {alpha}/{beta}} subdomain and an aspartate (Asp129) on the EIN{sup {alpha}} subdomain results in a small ({approx}9{sup o}) reorientation of the EIN{sup {alpha}} and EIN{sup {alpha}/{beta}} subdomains that is in turn propagated to a larger reorientation ({approx}26{sup o}) of the EIN domain relative to the EIC dimerization domain, illustrating the positional sensitivity of the EIN domain and its constituent subdomains to small structural perturbations.« less
Out-of-plane (SH) soil-structure interaction: a shear wall with rigid and flexible ring foundation
NASA Astrophysics Data System (ADS)
Le, Thang; Lee, Vincent W.; Luo, Hao
2016-02-01
Soil-structure interaction (SSI) of a building and shear wall above a foundation in an elastic half-space has long been an important research subject for earthquake engineers and strong-motion seismologists. Numerous papers have been published since the early 1970s; however, very few of these papers have analytic closed-form solutions available. The soil-structure interaction problem is one of the most classic problems connecting the two disciplines of earthquake engineering and civil engineering. The interaction effect represents the mechanism of energy transfer and dissipation among the elements of the dynamic system, namely the soil subgrade, foundation, and superstructure. This interaction effect is important across many structure, foundation, and subgrade types but is most pronounced when a rigid superstructure is founded on a relatively soft lower foundation and subgrade. This effect may only be ignored when the subgrade is much harder than a flexible superstructure: for instance a flexible moment frame superstructure founded on a thin compacted soil layer on top of very stiff bedrock below. This paper will study the interaction effect of the subgrade and the superstructure. The analytical solution of the interaction of a shear wall, flexible-rigid foundation, and an elastic half-space is derived for incident SH waves with various angles of incidence. It found that the flexible ring (soft layer) cannot be used as an isolation mechanism to decouple a superstructure from its substructure resting on a shaking half-space.
NASA Astrophysics Data System (ADS)
Roh, Jeongkyun; Lee, Taesoo; Kang, Chan-Mo; Kwak, Jeonghun; Lang, Philippe; Horowitz, Gilles; Kim, Hyeok; Lee, Changhee
2017-04-01
We demonstrated modulation of charge carrier densities in all-solution-processed organic field-effect transistors (OFETs) by modifying the injection properties with self-assembled monolayers (SAMs). The all-solution-processed OFETs based on an n-type polymer with inkjet-printed Ag electrodes were fabricated as a test platform, and the injection properties were modified by the SAMs. Two types of SAMs with different dipole direction, thiophenol (TP) and pentafluorobenzene thiol (PFBT) were employed, modifying the work function of the inkjet-printed Ag (4.9 eV) to 4.66 eV and 5.24 eV with TP and PFBT treatments, respectively. The charge carrier densities were controlled by the SAM treatment in both dominant and non-dominant carrier-channel regimes. This work demonstrates that control of the charge carrier densities can be efficiently achieved by modifying the injection property with SAM treatment; thus, this approach can achieve polarity conversion of the OFETs.
Radial solute transport in highly heterogeneous aquifers: Modeling and experimental comparison
NASA Astrophysics Data System (ADS)
Di Dato, Mariaines; Fiori, Aldo; de Barros, Felipe P. J.; Bellin, Alberto
2017-07-01
We analyze solute transport in a radially converging 3-D flow field in a porous medium with spatially heterogeneous hydraulic conductivity (K). The aim of the paper is to analyze the impact of heterogeneity and the mode of injection on BreakThrough Curves (BTCs) detected at a well pumping a contaminated aquifer. The aquifer is conceptualized as an ensemble of blocks of uniform but contrasting K and the analysis makes use of the travel time approach. Despite the approximations introduced, the model reproduces a laboratory experiment without calibration of transport parameters. Our results also show excellent agreement with numerical simulations for different levels of heterogeneity. We focus on the impact on the BTC of both heterogeneity in K and solute release conditions. It is shown that the injection mode matters, and the differences in the BTCs between uniform and flux-proportional injection increase with the heterogeneity of the K-field. Furthermore, we study the effect of heterogeneity and mode of injection on early and late arrivals at the well.
Direct numerical simulation of particulate flows with an overset grid method
NASA Astrophysics Data System (ADS)
Koblitz, A. R.; Lovett, S.; Nikiforakis, N.; Henshaw, W. D.
2017-08-01
We evaluate an efficient overset grid method for two-dimensional and three-dimensional particulate flows for small numbers of particles at finite Reynolds number. The rigid particles are discretised using moving overset grids overlaid on a Cartesian background grid. This allows for strongly-enforced boundary conditions and local grid refinement at particle surfaces, thereby accurately capturing the viscous boundary layer at modest computational cost. The incompressible Navier-Stokes equations are solved with a fractional-step scheme which is second-order-accurate in space and time, while the fluid-solid coupling is achieved with a partitioned approach including multiple sub-iterations to increase stability for light, rigid bodies. Through a series of benchmark studies we demonstrate the accuracy and efficiency of this approach compared to other boundary conformal and static grid methods in the literature. In particular, we find that fully resolving boundary layers at particle surfaces is crucial to obtain accurate solutions to many common test cases. With our approach we are able to compute accurate solutions using as little as one third the number of grid points as uniform grid computations in the literature. A detailed convergence study shows a 13-fold decrease in CPU time over a uniform grid test case whilst maintaining comparable solution accuracy.
Rapid colorimetric assay for gentamicin injection.
Tarbutton, P
1987-01-01
A rapid colorimetric method for determining gentamicin concentration in commercial preparations of gentamicin sulfate injection was developed. Methods currently available for measuring gentamicin concentration via its colored complex with cupric ions in alkaline solution were modified to reduce the time required for a single analysis. The alkaline copper tartrate (ACT) reagent solution was prepared such that each milliliter contained 100 mumol cupric sulfate, 210 mumol potassium sodium tartrate, and 1.25 mmol sodium hydroxide. The assay involves mixing 0.3 mL gentamicin sulfate injection 40 mg/mL (of gentamicin), 1.0 mL ACT reagent, and 0.7 mL water; the absorbance of the resulting solution at 560 nm was used to calculate the gentamicin concentration in the sample. For injections containing 10 mg/mL of gentamicin, the amount of the injection was increased to 0.5 mL and water decreased to 0.5 mL. The concentration of gentamicin in samples representing 11 lots of gentamicin sulfate injection 40 mg/mL and 8 lots of gentamicin sulfate injection 10 mg/mL was determined. The specificity, reproducibility, and accuracy of the assay were assessed. The colored complex was stable for at least two hours. Gentamicin concentration ranged from 93.7 to 108% and from 95 to 109% of the stated label value of the 40 mg/mL and the 10 mg/mL injections, respectively. No components of the preservative system present in the injections interfered with the assay. Since other aminoglycosides produced a colored complex, the assay is not specific for gentamicin. The assay was accurate and reproducible over the range of 4-20 mg of gentamicin. This rapid and accurate assay can be easily applied in the hospital pharmacy setting.
Spatio-temporal droplet size statistics in developing spray of starchy solution
NASA Astrophysics Data System (ADS)
Naz, Muhammad Yasin; Sulaiman, Shaharin Anwar; Ariwahjoedi, Bambang
2015-07-01
In the given research, the spray jet breakup of a modified starch solution was studied as a function of jet injection time and nozzle orifice diameter. The starch-urea-borax solution was prepared and tested with three axisymmetric full cone nozzles at service temperature of 80°C and the injection pressure of 5 bar. It is worth mentioning that no jet breakup was seen below these temperature and pressure values. The imaging studies on the time based spray evolution revealed monotonic increase in both; spray cone angle and tip penetration with an increase in injection time form 0-300 mm. Hereinafter, both parameters exhibited constants value over injection time. Phase Doppler Anemometry (PDA) measurements of the droplet size revealed significant decrease in the Sauter Mean Diameter (SMD) along the spray centerline. However, a steady decrease in SMD was seen towards the spray boundary. For fixed injection time of 300 ms, the overall SMD was decreased from 112 to 71 µm at 60 mm downstream, from 102 to 64 µm at 100 mm downstream and from 85 to 61 µm at 140 mm downstream with an increase in orifice diameter from 1.19 to 1.59 mm.
Kur'yanova, E V; Tryasuchev, A V; Stupin, V O; Teplyi, D L
2017-05-01
We studied heart rate variability and β-adrenergic responsiveness of erythrocytes and changes in these parameters in response to single administration of β-adrenoblocker propranolol (2 mg/kg) in outbred male rats against the background of activation of the noradrenergic, serotonergic, and dopaminergic neurotransmitter systems achieved by 4-fold injections maprotiline (10 mg/kg), 5-hydroxytryptophan (50 mg/kg) combined with fluoxetine (3 mg/kg), and L-DOPA (20 mg/kg) with amantadine (20 mg/kg), respectively. Stimulation of the noradrenergic system moderately enhanced the heart rhythm rigidity and β-adrenergic responsiveness of erythrocytes. In addition, it markedly augmented the moderating effect of subsequently administered propranolol on LF and VLF components in the heart rate variability and reversed the effect of propranolol on β-adrenergic responsiveness of erythrocytes. Stimulation of the serotonergic system dramatically decreased all components in the heart rate variability and pronouncedly enhanced β-adrenergic responsiveness of erythrocytes. Subsequent injection of propranolol slightly restored all components in the heart rate variability and decreased β-adrenergic responsiveness of erythrocytes to the control level. Stimulation of the dopaminergic system made the heart rate more rigid due to decrease of all components in the heart rate variability; in addition, it slightly but significantly enhanced β-adrenergic responsiveness of erythrocytes. Subsequent injection of propranolol produced no significant effects on all components in the heart rate variability and on β-adrenergic responsiveness of erythrocytes. Stimulation of noradrenergic, serotonergic, and dopaminergic neurotransmitter systems produced unidirectional and consorted effects on heart rate variability and β-adrenergic responsiveness of erythrocytes, although the magnitudes of these effects were different. Probably, the changes in the heart rate variability in rats with stimulated neurotransmitter systems results from modification of the cellular sensitivity in peripheral organs to adrenergic influences. However, the differences in the reactions to β-adrenoblocker attest to specificity of the mechanisms underlying the changes in membrane reception and adrenergic pathways in every experimental model employed in this study.
Analytical solutions to non-Fickian subsurface dispersion in uniform groundwater flow
Zou, S.; Xia, J.; Koussis, Antonis D.
1996-01-01
Analytical solutions are obtained by the Fourier transform technique for the one-, two-, and three-dimensional transport of a conservative solute injected instantaneously in a uniform groundwater flow. These solutions account for dispersive non-linearity caused by the heterogeneity of the hydraulic properties of aquifer systems and can be used as building blocks to construct solutions by convolution (principle of superposition) for source conditions other than slug injection. The dispersivity is assumed to vary parabolically with time and is thus constant for the entire system at any given time. Two approaches for estimating time-dependent dispersion parameters are developed for two-dimensional plumes. They both require minimal field tracer test data and, therefore, represent useful tools for assessing real-world aquifer contamination sites. The first approach requires mapped plume-area measurements at two specific times after the tracer injection. The second approach requires concentration-versus-time data from two sampling wells through which the plume passes. Detailed examples and comparisons with other procedures show that the methods presented herein are sufficiently accurate and easier to use than other available methods.
MICRURGICAL STUDIES IN CELL PHYSIOLOGY
Chambers, Robert; Reznikoff, Paul
1926-01-01
By means of micro-dissection and injection Amœba proteus was treated with the chlorides of Na, K, Ca, and Mg alone, in combination, and with variations of pH. I. The Plasmalemma. 1. NaCl weakens and disrupts the surface membrane of the ameba. Tearing the membrane accelerates the disruption which spreads rapidly from the site of the tear. KCl has no disruptive effect on the membrane but renders it adhesive. 2. MgCl2 and CaCl2 have no appreciable effect on the integrity of the surface membrane of the ameba when applied on the outside. No spread of disruption occurs when the membrane is torn in these salts. When these salts are introduced into the ameba they render the pellicle of the involved region rigid. II. The Internal Protoplasm. 3. Injected water either diffuses through the protoplasm or becomes localized in a hyaline blister. Large amounts when rapidly injected produce a "rushing effect". 4. HCl at pH 1.8 solidifies the internal protoplasm and at pH 2.2 causes solidification only after several successive injections. The effect of the subsequent injections may be due to the neutralization of the cell-buffers by the first injection. 5. NaCl and KCl increase the fluidity of the internal protoplasm and induce quiescence. 6. CaCl2 and MgCl2 to a lesser extent solidify the internal protoplasm. With CaCl2 the solidification tends to be localized. With MgCl2 it tends to spread. The injection of CaCl2 accelerates movement in the regions not solidified whereas the injection of MgCl2 induces quiescence. III. Pinching-Off Reaction. 7. A hyaline blister produced by the injection of water may be pinched off. The pinched-off blister is a liquid sphere surrounded by a pellicle. 8. Pinching off always takes place with injections of HCl when the injected region is solidified. 9. The injection of CaCl2 usually results in the pinching off of the portion solidified. The rate of pinching off varies with the concentration of the salt. The injection of MgCl2 does not cause pinching off. IV. Reparability of Torn Surfaces. 10. The repair of a torn surface takes place readily in distilled water. In the different salt solutions, reparability varies specifically with each salt, with the concentration of the salt, and with the extent of the tear. In NaCl and in KCl repair occurs less readily than in water. In MgCl2 repair takes place with great difficulty. In CaCl2 a proper estimate of the process of repair is complicated by the pinching-off phenomenon. However, CaCl2 is the only salt found to increase the mobility of the plasmalemma, and this presumably enhances its reparability. 11. The repair of the surface is probably a function of the internal protoplasm and depends upon an interaction of the protoplasm with the surrounding medium. V. Permeability. 12. NaCl and KCl readily penetrate the ameba from the exterior. CaCl2 and MgCl2 do not. 13. All four salts when injected into an ameba readily diffuse through the internal protoplasm. In the case of CaCl2 the diffusion may be arrested by the pinching-off process. VI. Toxicity. 14. NaCl and KCl are more toxic to the exterior of the cell than to the interior, and the reverse is true for CaCl2 and MgCl2. 15. The relative non-toxicity of injected NaCl to the interior of the ameba is not necessarily due to its diffusion outward from the cell. 16. HCl is much more toxic to the exterior of a cell than to the interior; at pH 5.5 it is toxic to the surface whereas at pH 2.5 it is not toxic to the interior. NaOH to pH 9.8 is not toxic either to the surface or to the interior. VII. Antagonism. 17. The toxic effects of NaCl and of KCl on the exterior of the cell can be antagonized by CaCl2 and this antagonism occurs at the surface. Although the lethal effect of NaCl is thus antagonized, NaCl still penetrates but at a slower rate than if the ameba were immersed in a solution of this salt alone. 18. NaCl and HCl are mutually antagonistic in the interior of the ameba. No antagonism between the salts and HCl was found on the exterior of the ameba. No antagonism between the salts and NaOH was found on the interior or exterior of the ameba. 19. The pinching-off phenomenon can be antagonized by NaCl or by KCl, and the rate of the retardation of the pinching-off process varies with the concentration of the antagonizing salt. 20. The prevention of repair of a torn membrane by toxic solutions of NaCl or KCl can be antagonized by CaCl2. These experiments show directly the marked difference between the interior and the exterior of the cell in their behavior toward the chlorides of Na, K, Ca, and Mg. PMID:19872206
Ay, Sinan; Küçük, Dervisşhan; Gümüş, Cesur; Kara, M Isa
2011-11-01
The aim of this study was to evaluate the distribution and absorption of local anesthetic solutions in inferior alveolar nerve block using magnetic resonance imaging. Forty healthy volunteers were divided into 4 groups and injected with 1.5 mL for inferior alveolar nerve block and 0.3 mL for lingual nerve block. The solutions used for the different groups were 2% lidocaine, 2% lidocaine with 0.125 mg/mL epinephrine, 4% articaine with 0.006 mg/mL epinephrine, and 4% articaine with 0.012 mg/mL epinephrine. All subjects had axial T2-weighted and fat-suppressed images at 0, 60, and 120 minutes after injection. The localization, area, and intensity (signal characteristics) of the solutions were analyzed and onset and duration times of the anesthesia were recorded. There were no significant differences between groups with regard to the intensity and area of the solutions at 0, 60, and 120 minutes after injection, but differences were found within each group. No between-group differences were found on magnetic resonance imaging in the distribution and absorption of lidocaine with or without epinephrine and articaine with 0.006 and 0.012 mg/mL epinephrine. All solutions were noticeably absorbed at 120 minutes after injection. Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Gao, T; Zhao, M M; Li, Y J; Zhang, L; Li, J L; Yu, L L; Gao, F; Zhou, G H
2018-02-01
This study was to investigate the effects of in ovo feeding (IOF) L-arginine (Arg) solution on the development of digestive organs, the duodenal mucosa of broiler embryos and hatchlings, and the growth performance of chicks during the first week post-hatch. A total of 720 fertilized eggs with similar weight were randomly allocated to three groups, consisting of eight replicates of 30 eggs each. Three treatments were arranged as non-injected control, diluent-injected (0.75% NaCl solution) group and Arg solution-injected group containing 1% Arg, dissolved in diluent. At 17.5 days of incubation, 0.6 ml of IOF solution was injected into amniotic fluid of each egg of injected groups. Results showed IOF of Arg solution increased (p < .05) the chick embryo weight at 19 days of incubation; the body weight gain of post-hatch broilers during 1-7 days; the weights of liver, pancreas, proventriculus and gizzard; the concentrations of duodenal ghrelin, vasoactive intestinal peptide and glucagon-like peptide 2; and the duodenum mucosal enzyme activities of alkaline phosphatase, maltase, sucrase and inducible nitric oxide synthase of 7-day-old post-hatch broilers compared with other groups. The IOF of Arg solution also increased (p < .05) the villus height (VH) and the ratio of VH to crypt depth (CD) and decreased (p < .05) the CD in duodenum of broiler embryos and post-hatch hatchlings, except for the CD at 19 days of incubation. In conclusion, IOF of 1% Arg solution into the amnion at 17.5 days of incubation could improve the development of digestive organs, the duodenal morphology, the releasing of gastrointestinal hormones and mucosal enzyme activities of broiler embryos and hatchlings and finally the growth performance of chicks during the first week post-hatch. Therefore, IOF of appropriate Arg solution could be an effective technology for regulating early nutrition supply and subsequent growth development in poultry industry. © 2017 Blackwell Verlag GmbH.
Conditions for a steady ice sheet ice shelf junction
NASA Astrophysics Data System (ADS)
Nowicki, S. M. J.; Wingham, D. J.
2008-01-01
This paper investigates the conditions under which a marine ice sheet may adopt a steady profile. The ice is treated as a linear viscous fluid caused to flow from a rigid base to and over water, treated as a denser but inviscid fluid. The solutions in the region around the point of flotation, or 'transition' zone, are calculated numerically. In-flow and out-flow conditions appropriate to ice sheet and ice shelf flow are applied at the ends of the transition zone and the rigid base is specified; the flow and steady free surfaces are determined as part of the solutions. The basal stress upstream, and the basal deflection downstream, of the flotation point are examined to determine which of these steady solutions satisfy 'contact' conditions that would prevent (i) the steady downstream basal deflection contacting the downstream base, and (ii) the upstream ice commencing to float in the event it was melted at the base. In the case that the upstream bed is allowed to slide, we find only one mass flux that satisfies the contact conditions. When no sliding is allowed at the bed, however, we find a range of mass fluxes satisfy the contact conditions. The effect of 'backpressure' on the solutions is investigated, and is found to have no affect on the qualitative behaviour of the junctions. To the extent that the numerical, linearly viscous treatment may be applied to the case of ice flowing out over the ocean, we conclude that when sliding is present, Weertman's 'instability' hypothesis holds.
Three Dimensional Solution of Pneumatic Active Control of Forebody Vortex Asymmetry
NASA Technical Reports Server (NTRS)
Kandil, Osama A.; SharafEl-Din, Hazem H.; Liu, C. H.
1995-01-01
Pneumatic active control of asymmetric vortical flows around a slender pointed forebody is investigated using the three dimensional solution for the compressible thin-layer Navier-Stokes equation. The computational applications cover the normal and tangential injection control of asymmetric flows around a 5 degree semi-apex angle cone at a 40 degree angle of attack, 1.4 freestream Mach number and 6 x 10(exp 6) freestream Reynolds number (based on the cone length). The effective tangential angle range of 67.5 approaches minus 67.5 degrees is used for both normal and tangential ports of injection. The effective axial length of injection is varied from 0.03 to 0.05. The computational solver uses the implicit, upwind, flux difference splitting finite volume scheme, and the grid consists of 161 x 55 x 65 points in the wrap around, normal and axial directions, respectively. The results show that tangential injection is more effective than normal injection.
2008-03-01
consider the origin of the parachute they probably envision the pyramidal drawing of Leonardo da Vinci from the late 1400s. However, the Chinese are...refining their designs. Like da Vinci’s plan, most had a rigid frame limiting their versatility. The practical use for the parachute was
Modal ring method for the scattering of sound
NASA Technical Reports Server (NTRS)
Baumeister, Kenneth J.; Kreider, Kevin L.
1993-01-01
The modal element method for acoustic scattering can be simplified when the scattering body is rigid. In this simplified method, called the modal ring method, the scattering body is represented by a ring of triangular finite elements forming the outer surface. The acoustic pressure is calculated at the element nodes. The pressure in the infinite computational region surrounding the body is represented analytically by an eigenfunction expansion. The two solution forms are coupled by the continuity of pressure and velocity on the body surface. The modal ring method effectively reduces the two-dimensional scattering problem to a one-dimensional problem capable of handling very high frequency scattering. In contrast to the boundary element method or the method of moments, which perform a similar reduction in problem dimension, the model line method has the added advantage of having a highly banded solution matrix requiring considerably less computer storage. The method shows excellent agreement with analytic results for scattering from rigid circular cylinders over a wide frequency range (1 is equal to or less than ka is less than or equal to 100) in the near and far fields.
NASA Technical Reports Server (NTRS)
Wadlin, Kenneth L; Shuford, Charles L , Jr; Mcgehee, John R
1955-01-01
A theoretical and experimental investigation at subcavitation speeds was made of the effect of the free-water surface and rigid boundaries on the lift and drag of an aspect-ratio-10 hydrofoil at both subcritical and supercritical speeds and of an aspect ratio-4 hydrofoil at supercritical speeds. Approximate theoretical solutions for the effects of the free-water surface and rigid boundaries on drag at subcritical speeds are developed. An approximate theoretical solution for the effects of these boundaries on drag at subcritical speeds is also presented. The agreement between theory and experiment at both supercritical and subcritical speeds is satisfactory for engineering calculations of hydrofoil characteristics from aerodynamic data. The experimental investigation indicated no appreciable effect of the limiting speed of wave propagation on lift-curve slope or angle of zero lift. It also showed that the increase in drag as the critical speed is approached from the supercritical range is gradual. The result is contrary to the abrupt increase at the critical speed predicted by theory.
Numerical simulation of liquid jet impact on a rigid wall
NASA Astrophysics Data System (ADS)
Aganin, A. A.; Guseva, T. S.
2016-11-01
Basic points of a numerical technique for computing high-speed liquid jet impact on a rigid wall are presented. In the technique the flows of the liquid and the surrounding gas are governed by the equations of gas dynamics in the density, velocity, and pressure, which are integrated by the CIP-CUP method on dynamically adaptive grids without explicitly tracking the gas-liquid interface. The efficiency of the technique is demonstrated by the results of computing the problems of impact of the liquid cone and the liquid wedge on a wall in the mode with the shockwave touching the wall by its edge. Numerical solutions of these problems are compared with the analytical solution of the problem of impact of the plane liquid flow on a wall. Applicability of the technique to the problems of the high-speed liquid jet impact on a wall is illustrated by the results of computing a problem of impact of a cylindrical liquid jet with the hemispherical end on a wall covered by a layer of the same liquid.
NASA Technical Reports Server (NTRS)
Aftosmis, M. J.; Berger, M. J.; Murman, S. M.; Kwak, Dochan (Technical Monitor)
2002-01-01
The proposed paper will present recent extensions in the development of an efficient Euler solver for adaptively-refined Cartesian meshes with embedded boundaries. The paper will focus on extensions of the basic method to include solution adaptation, time-dependent flow simulation, and arbitrary rigid domain motion. The parallel multilevel method makes use of on-the-fly parallel domain decomposition to achieve extremely good scalability on large numbers of processors, and is coupled with an automatic coarse mesh generation algorithm for efficient processing by a multigrid smoother. Numerical results are presented demonstrating parallel speed-ups of up to 435 on 512 processors. Solution-based adaptation may be keyed off truncation error estimates using tau-extrapolation or a variety of feature detection based refinement parameters. The multigrid method is extended to for time-dependent flows through the use of a dual-time approach. The extension to rigid domain motion uses an Arbitrary Lagrangian-Eulerlarian (ALE) formulation, and results will be presented for a variety of two- and three-dimensional example problems with both simple and complex geometry.
Repurposing the Microsoft Kinect for Windows v2 for external head motion tracking for brain PET.
Noonan, P J; Howard, J; Hallett, W A; Gunn, R N
2015-11-21
Medical imaging systems such as those used in positron emission tomography (PET) are capable of spatial resolutions that enable the imaging of small, functionally important brain structures. However, the quality of data from PET brain studies is often limited by subject motion during acquisition. This is particularly challenging for patients with neurological disorders or with dynamic research studies that can last 90 min or more. Restraining head movement during the scan does not eliminate motion entirely and can be unpleasant for the subject. Head motion can be detected and measured using a variety of techniques that either use the PET data itself or an external tracking system. Advances in computer vision arising from the video gaming industry could offer significant benefits when re-purposed for medical applications. A method for measuring rigid body type head motion using the Microsoft Kinect v2 is described with results presenting ⩽0.5 mm spatial accuracy. Motion data is measured in real-time at 30 Hz using the KinectFusion algorithm. Non-rigid motion is detected using the residual alignment energy data of the KinectFusion algorithm allowing for unreliable motion to be discarded. Motion data is aligned to PET listmode data using injected pulse sequences into the PET/CT gantry allowing for correction of rigid body motion. Pilot data from a clinical dynamic PET/CT examination is shown.
Repurposing the Microsoft Kinect for Windows v2 for external head motion tracking for brain PET
NASA Astrophysics Data System (ADS)
Noonan, P. J.; Howard, J.; Hallett, W. A.; Gunn, R. N.
2015-11-01
Medical imaging systems such as those used in positron emission tomography (PET) are capable of spatial resolutions that enable the imaging of small, functionally important brain structures. However, the quality of data from PET brain studies is often limited by subject motion during acquisition. This is particularly challenging for patients with neurological disorders or with dynamic research studies that can last 90 min or more. Restraining head movement during the scan does not eliminate motion entirely and can be unpleasant for the subject. Head motion can be detected and measured using a variety of techniques that either use the PET data itself or an external tracking system. Advances in computer vision arising from the video gaming industry could offer significant benefits when re-purposed for medical applications. A method for measuring rigid body type head motion using the Microsoft Kinect v2 is described with results presenting ⩽0.5 mm spatial accuracy. Motion data is measured in real-time at 30 Hz using the KinectFusion algorithm. Non-rigid motion is detected using the residual alignment energy data of the KinectFusion algorithm allowing for unreliable motion to be discarded. Motion data is aligned to PET listmode data using injected pulse sequences into the PET/CT gantry allowing for correction of rigid body motion. Pilot data from a clinical dynamic PET/CT examination is shown.
21 CFR 522.536 - Detomidine hydrochloride injection.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Detomidine hydrochloride injection. 522.536... § 522.536 Detomidine hydrochloride injection. (a) Specification. Each milliliter of sterile aqueous solution contains 10 milligrams of detomidine hydrochloride. (b) Sponsor. See 052483 in § 510.600(c) of...
SORBENT/UREA SLURRY INJECTION FOR SIMULTANEOUS SO2/NOX REMOVAL
The combination of sorbent injection and selective noncatalytic reduction (SNCR) technologies has been investigated for simulataneous SO2/NOx removal. A slurry composed of a urea-based solution and various Ca-based sorbents was injected at a range of tempera...
21 CFR 522.995 - Fluprostenol sodium injection.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Fluprostenol sodium injection. 522.995 Section 522....995 Fluprostenol sodium injection. (a) Specifications. Each milliliter of sterile aqueous solution contains fluprostenol sodium equivalent to 50 micrograms of fluprostenol. (b) Sponsor. See 000859 in § 510...
21 CFR 522.995 - Fluprostenol sodium injection.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Fluprostenol sodium injection. 522.995 Section 522....995 Fluprostenol sodium injection. (a) Specifications. Each milliliter of sterile aqueous solution contains fluprostenol sodium equivalent to 50 micrograms of fluprostenol. (b) Sponsor. See 000859 in § 510...
Rigid supersymmetric backgrounds of 3-dimensional Newton-Cartan supergravity
Knodel, Gino; Lisbao, Pedro; Liu, James T.
2016-06-06
Recently, a non-relativistic off-shell formulation of three dimensional Newton-Cartan supergravity was proposed as the c → ∞ limit of three dimensional N = 2 super-gravity [1]. Here in the present paper we study supersymmetric backgrounds within this theory. Using integrability constraints for the non-relativistic Killing spinor equations, we explicitly construct all maximally supersymmetric solutions, which admit four supercharges. In addition to these solutions, there aremore » $$\\frac{1}{2}$$ -BPS solutions with reduced supersymmetry. We give explicit examples of such backgrounds and derive necessary conditions for backgrounds preserving two supercharges. Finally, we address how supersymmetric backgrounds of N = 2 supergravity are connected to the solutions found here in the c → ∞ limit.« less
Eiden, Céline; Philibert, Laurent; Bekhtari, Khedidja; Poujol, Sylvain; Malosse, Francoise; Pinguet, Frédéric
2009-11-01
The physicochemical stability of extemporaneous dilutions of oxaliplatin in 5% dextrose injection stored in polyvinyl chloride (PVC), polypropylene, and polyethylene infusion bags was studied. Oxaliplatin 100 mg/20 mL concentrated solution was diluted in 100 mL of 5% dextrose injection in PVC, polypropylene, and polyethylene infusion bags to produce nominal oxaliplatin concentrations of 0.2 and 1.3 mg/mL. The filled bags were stored for 14 days at 20 degrees C and protected from light, at 20 degrees C under normal fluorescent light, and at 4 degrees C. A 1-mL sample was removed from each bag at time 0 and at 24, 48, 72, 120, 168, and 336 hours. The samples were visually inspected for color and clarity, and the pH values of the solutions were measured. High-performance liquid chromatography was used to assay oxaliplatin concentration. Bacterial contamination was assessed on study day 14 after incubation in trypticase soy solution for three days at 37 degrees C. Solutions of oxaliplatin 0.2 and 1.3 mg/mL in 5% dextrose injection were stable in the three container types for at least 14 days at both 4 degrees C and 20 degrees C without regard to light exposure. No color change was detected during the storage period, and pH values remained stable. No microbial contamination was detected in any samples over the study period. Oxaliplatin solutions diluted in 5% dextrose injection to 0.2 and 1.3 mg/mL were stable in PVC and PVC-free infusion bags for at least 14 days at both 4 degrees C and 20 degrees C without regard to light exposure.
NASA Astrophysics Data System (ADS)
Petruk, O.; Kopytko, B.
2016-11-01
Three approaches are considered to solve the equation which describes the time-dependent diffusive shock acceleration of test particles at the non-relativistic shocks. At first, the solution of Drury for the particle distribution function at the shock is generalized to any relation between the acceleration time-scales upstream and downstream and for the time-dependent injection efficiency. Three alternative solutions for the spatial dependence of the distribution function are derived. Then, the two other approaches to solve the time-dependent equation are presented, one of which does not require the Laplace transform. At the end, our more general solution is discussed, with a particular attention to the time-dependent injection in supernova remnants. It is shown that, comparing to the case with the dominant upstream acceleration time-scale, the maximum momentum of accelerated particles shifts towards the smaller momenta with increase of the downstream acceleration time-scale. The time-dependent injection affects the shape of the particle spectrum. In particular, (I) the power-law index is not solely determined by the shock compression, in contrast to the stationary solution; (II) the larger the injection efficiency during the first decades after the supernova explosion, the harder the particle spectrum around the high-energy cutoff at the later times. This is important, in particular, for interpretation of the radio and gamma-ray observations of supernova remnants, as demonstrated on a number of examples.
Zhang, Jingtao; Liu, Weizhen; Gauthier, Olivier; Sourice, Sophie; Pilet, Paul; Rethore, Gildas; Khairoun, Khalid; Bouler, Jean-Michel; Tancret, Franck; Weiss, Pierre
2016-02-01
In this study, we propose a simple and effective strategy to prepare injectable macroporous calcium phosphate cements (CPCs) by syringe-foaming via hydrophilic viscous polymeric solution, such as using silanized-hydroxypropyl methylcellulose (Si-HPMC) as a foaming agent. The Si-HPMC foamed CPCs demonstrate excellent handling properties such as injectability and cohesion. After hardening the foamed CPCs possess hierarchical macropores and their mechanical properties (Young's modulus and compressive strength) are comparable to those of cancellous bone. Moreover, a preliminary in vivo study in the distal femoral sites of rabbits was conducted to evaluate the biofunctionality of this injectable macroporous CPC. The evidence of newly formed bone in the central zone of implantation site indicates the feasibility and effectiveness of this foaming strategy that will have to be optimized by further extensive animal experiments. A major challenge in the design of biomaterial-based injectable bone substitutes is the development of cohesive, macroporous and self-setting calcium phosphate cement (CPC) that enables rapid cell invasion with adequate initial mechanical properties without the use of complex processing and additives. Thus, we propose a simple and effective strategy to prepare injectable macroporous CPCs through syringe-foaming using a hydrophilic viscous polymeric solution (silanized-hydroxypropyl methylcellulose, Si-HPMC) as a foaming agent, that simultaneously meets all the aforementioned aims. Evidence from our in vivo studies shows the existence of newly formed bone within the implantation site, indicating the feasibility and effectiveness of this foaming strategy, which could be used in various CPC systems using other hydrophilic viscous polymeric solutions. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Wachholz, James J.; Murphy, David M.
1996-01-01
The SCARLET I (Solar Concentrator Army with Refractive Linear Element Technology) solar array wing was designed and built to demonstrate, in flight, the feasibility of integrating deployable concentrator optics within the design envelope of typical rigid array technology. Innovative mechanism designs were used throughout the array, and a full series of qualification tests were successfully performed in anticipation of a flight on the Multiple Experiment Transporter to Earth Orbit and Return (METEOR) spacecraft. Even though the Conestoga launch vehicle was unable to place the spacecraft in orbit, the program effort was successful in achieving the milestones of analytical and design development functional validation, and flight qualification, thus leading to a future flight evaluation for the SCARLET technology.
Bending and splitting of spoof surface acoustic waves through structured rigid surface
NASA Astrophysics Data System (ADS)
Xie, Sujun; Ouyang, Shiliang; He, Zhaojian; Wang, Xiaoyun; Deng, Ke; Zhao, Heping
2018-03-01
In this paper, we demonstrated that a 90°-bended imaging of spoof surface acoustic waves with subwavelength resolution of 0.316λ can be realized by a 45° prism-shaped surface phononic crystal (SPC), which is composed of borehole arrays with square lattice in a rigid plate. Furthermore, by combining two identical prism-shaped phononic crystal to form an interface (to form a line-defect), the excited spoof surface acoustic waves can be split into bended and transmitted parts. The power ratio between the bended and transmitted surface waves can be tuned arbitrarily by adjusting the defect size. This acoustic system is believed to have potential applications in various multifunctional acoustic solutions integrated by different acoustical devices.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wachholz, J.J.; Murphy, D.M.
1996-05-01
The SCARLET I (Solar Concentrator Army with Refractive Linear Element Technology) solar array wing was designed and built to demonstrate, in flight, the feasibility of integrating deployable concentrator optics within the design envelope of typical rigid array technology. Innovative mechanism designs were used throughout the array, and a full series of qualification tests were successfully performed in anticipation of a flight on the Multiple Experiment Transporter to Earth Orbit and Return (METEOR) spacecraft. Even though the Conestoga launch vehicle was unable to place the spacecraft in orbit, the program effort was successful in achieving the milestones of analytical and designmore » development functional validation, and flight qualification, thus leading to a future flight evaluation for the SCARLET technology.« less
Remote sensing applied to numerical modelling. [water resources pollution
NASA Technical Reports Server (NTRS)
Sengupta, S.; Lee, S. S.; Veziroglu, T. N.; Bland, R.
1975-01-01
Progress and remaining difficulties in the construction of predictive mathematical models of large bodies of water as ecosystems are reviewed. Surface temperature is at present the only variable than can be measured accurately and reliably by remote sensing techniques, but satellite infrared data are of sufficient resolution for macro-scale modeling of oceans and large lakes, and airborne radiometers are useful in meso-scale analysis (of lakes, bays, and thermal plumes). Finite-element and finite-difference techniques applied to the solution of relevant coupled time-dependent nonlinear partial differential equations are compared, and the specific problem of the Biscayne Bay and environs ecosystem is tackled in a finite-differences treatment using the rigid-lid model and a rigid-line grid system.
NASA Astrophysics Data System (ADS)
Li, Wei; Chai, Yingbin; Gong, Zhixiong; Marston, Philip L.
2017-10-01
The forward scattering from rigid spheroids and endcapped cylinders with finite length (even with a large aspect ratio) immersed in a non-viscous fluid under the illumination of an idealized zeroth-order acoustical Bessel beam (ABB) with arbitrary angles of incidence is calculated and analyzed in the implementation of the T-matrix method (TTM). Based on the present method, the incident coefficients of expansion for the incident ABB are derived and simplifying methods are proposed for the numerical accuracy and computational efficiency according to the geometrical symmetries. A home-made MATLAB software package is constructed accordingly, and then verified and validated for the ABB scattering from rigid aspherical obstacles. Several numerical examples are computed for the forward scattering from both rigid spheroids and finite cylinder, with particular emphasis on the aspect ratios, the half-cone angles of ABBs, the incident angles and the dimensionless frequencies. The rectangular patterns of target strength in the (β, θs) domain (where β is the half-cone angle of the ABB and θs is the scattered polar angle) and local/total forward scattering versus dimensionless frequency are exhibited, which could provide new insights into the physical mechanisms of Bessel beam scattering by rigid spheroids and finite cylinders. The ray diagrams in geometrical models for the scattering in the forward half-space and the optical cross-section theorem help to interpret the scattering mechanisms of ABBs. This research work may provide an alternative for the partial wave series solution under certain circumstances interacting with ABBs for complicated obstacles and benefit some related works in optics and electromagnetics.
Geomagnetic Cutoff Rigidity Computer Program: Theory, Software Description and Example
NASA Technical Reports Server (NTRS)
Smart, D. F.; Shea, M. A.
2001-01-01
The access of charged particles to the earth from space through the geomagnetic field has been of interest since the discovery of the cosmic radiation. The early cosmic ray measurements found that cosmic ray intensity was ordered by the magnetic latitude and the concept of cutoff rigidity was developed. The pioneering work of Stoermer resulted in the theory of particle motion in the geomagnetic field, but the fundamental mathematical equations developed have 'no solution in closed form'. This difficulty has forced researchers to use the 'brute force' technique of numerical integration of individual trajectories to ascertain the behavior of trajectory families or groups. This requires that many of the trajectories must be traced in order to determine what energy (or rigidity) a charged particle must have to penetrate the magnetic field and arrive at a specified position. It turned out the cutoff rigidity was not a simple quantity but had many unanticipated complexities that required many hundreds if not thousands of individual trajectory calculations to solve. The accurate calculation of particle trajectories in the earth's magnetic field is a fundamental problem that limited the efficient utilization of cosmic ray measurements during the early years of cosmic ray research. As the power of computers has improved over the decades, the numerical integration procedure has grown more tractable, and magnetic field models of increasing accuracy and complexity have been utilized. This report is documentation of a general FORTRAN computer program to trace the trajectory of a charged particle of a specified rigidity from a specified position and direction through a model of the geomagnetic field.
An anatomic study of local infiltration analgesia in total knee arthroplasty.
Quinn, M; Deakin, A H; McDonald, D A; Cunningham, I K T; Payne, A P; Picard, F
2013-10-01
Local infiltration analgesia (LIA) is a relatively novel technique developed for effective pain control following total knee arthroplasty (TKA), reducing requirements for epidural or parenteral postoperative analgesia. This study investigated the anatomical spread of an LIA used in TKA to identify the nerve structures reached by the injected fluid. Six fresh-frozen cadaveric lower limbs were injected according to a standardised LIA technique with a solution of latex and India ink to enable visualisation. Wounds were closed and limbs placed flat in a freezer at -20°C for two weeks. Limbs were then either sliced or dissected to identify solution locations. Solution was found from the proximal thigh to the middle of the lower leg. The main areas of concentration were the popliteal fossa, the anterior aspect of the femur and the subcutaneous tissue of the anterior aspect of the knee. There was less solution in the lower popliteal fossa. The solution was found to reach the majority of nerves, with good infiltration of nerves supplying the knee. These results support the positive clinical outcomes with this LIA technique. However, the lack of infiltration into the lower popliteal fossa suggests more fluid or a different injection point could be used. The solution reaching the extensor muscles of the lower leg is likely to have no beneficial analgesic effect for a TKA patient. The LIA technique is already used in clinical practice following total knee arthroplasty. Results from this study show there may be scope to optimise the injection sites in LIA technique. © 2013.
Ineffectiveness of human chorionic gonadotropin in weight reduction: a double-blind study.
Stein, M R; Julis, R E; Peck, C C; Hinshaw, W; Sawicki, J E; Deller, J J
1976-09-01
Our investigation was designed to retest the hypothesis of the efficacy of human chorionic gonadotropin (HCG) on weight reduction in obese women in a clinic setting. We sought to duplicate the Asher-Harper study (1973) which had found that the combination of 500 cal diet and HCG had a statistically significant benefit over the diet and placebo combination as evidenced by greater weight loss and decrease in hunger. Fifty-one women between the ages of 18 and 60 participated in our 32-day prospective, randomized, double-blind comparison of HCG versus placebo. Each patient was given the same diet (the one prescribed in the Asher-Harper study), was weighed daily Monday through Saturday and was counselled by one of the investigators who administered the injections. Laboratory studies were performed at the time of initial physical examinations and at the end of the study. Twenty of 25 in the HCG and 21 of 26 patients in the placebo groups completed 28 injections. There was no statistically significant difference in the means of the two groups in number of injections received, weight loss, percent of weight loss, hip and waist circumference, weight loss per injections, or in hunger ratings. HCG does not appear to enhance the effectiveness of a rigidly imposed regimen for weight reduction.
Leaching of diethylhexyl phthalate from polyvinyl chloride bags into intravenous etoposide solution.
Demoré, B; Vigneron, J; Perrin, A; Hoffman, M A; Hoffman, M
2002-04-01
To compare the release of diethylhexyl phthalate (DEHP) from polyvinyl chloride (PVC) bags from four different manufacturers into intravenous etoposide solutions. Etoposide solutions, 0.4 mg/mL, containing the vehicle polysorbate 80 were prepared in 5% dextrose or 0.9% sodium chloride injection PVC bags and stored at room temperature for 24 h. DEHP content was analysed by high-performance liquid chromatography. Substantial amounts of DEHP (up to 20 microg/mL at room temperature) leached into the etoposide solutions. However, no significant differences were found in the amounts of DEHP leached into the etoposide infusion solutions prepared using either 5% dextrose or 0.9% sodium chloride injection and stored in the four different containers. To minimize patient exposure o DEHP, etoposide solutions should ideally be stored in a glass or polyolefin container.
21 CFR 522.1086 - Guaifenesin injection.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Guaifenesin injection. 522.1086 Section 522.1086... Guaifenesin injection. (a) Specifications. Each milliliter of sterile aqueous solution contains 50 milligrams of guaifenesin and 50 milligrams of dextrose. (b) Sponsor. See Nos. 037990 and 059130 in § 510.600(c...
21 CFR 522.1086 - Guaifenesin injection.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Guaifenesin injection. 522.1086 Section 522.1086... Guaifenesin injection. (a) Specifications. Each milliliter of sterile aqueous solution contains 50 milligrams of guaifenesin and 50 milligrams of dextrose. (b) Sponsor. See Nos. 037990 and 000859 in § 510.600(c...
21 CFR 522.1086 - Guaifenesin injection.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Guaifenesin injection. 522.1086 Section 522.1086... Guaifenesin injection. (a) Specifications. Each milliliter of sterile aqueous solution contains 50 milligrams of guaifenesin and 50 milligrams of dextrose. (b) Sponsor. See Nos. 037990 and 059130 in § 510.600(c...
21 CFR 522.1086 - Guaifenesin injection.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Guaifenesin injection. 522.1086 Section 522.1086... Guaifenesin injection. (a) Specifications. Each milliliter of sterile aqueous solution contains 50 milligrams of guaifenesin and 50 milligrams of dextrose. (b) Sponsor. See Nos. 037990 and 059130 in § 510.600(c...
21 CFR 522.144 - Arsenamide sodium aqueous injection.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Arsenamide sodium aqueous injection. 522.144... § 522.144 Arsenamide sodium aqueous injection. (a) Chemical name. [[(p-Carbamoylphenyl) arsylene]dithio diacetic acid, sodium salt. (b) Specifications. The drug is a sterile aqueous solution and each milliliter...
21 CFR 522.144 - Arsenamide sodium aqueous injection.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Arsenamide sodium aqueous injection. 522.144... § 522.144 Arsenamide sodium aqueous injection. (a) Chemical name. [[(p-Carbamoylphenyl) arsylene]dithio diacetic acid, sodium salt. (b) Specifications. The drug is a sterile aqueous solution and each milliliter...
... as a solution (liquid) to be given by infusion (injected into a vein). It is usually given ... doctor or nurse in a doctor's office or infusion center. Panitumumab is usually given once every 2 ...
In-situ generation of oxygen-releasing metal peroxides
Looney, Brian B.; Denham, Miles E.
2007-01-09
A method for remediation of contaminants in soil and groundwater is disclosed. The method generates oxygen releasing solids in groundwater or soil by injecting an aqueous energetic oxidant solution containing free radicals, oxidative conditions can be created within or ahead of a contaminant plume. Some contaminants may be remediated directly by reaction with the free radicals. Additionally and more importantly, the free radicals create an oxidative condition whereby native or injected materials, especially metals, are converted to peroxides. These peroxides provide a long-term oxygen reservoir, releasing oxygen relatively slowly over time. The oxygen can enhance microbial metabolism to remediate contaminants, can react with contaminant metals either to form immobile precipitants or to mobilize other metals to permit remediation through leaching techniques. Various injection strategies for injecting the energetic oxidant solution are also disclosed.
Bradford, Benjamin D; Seiberling, Kristin A; Park, Francine E; Hiebert, Jared C; Chang, Dennis F
2013-06-01
If not adequately cleaned, rigid nasal endoscopes (RNEs) have the potential to cause iatrogenic cross-contamination. To test the efficacy of various disinfection methods in reducing bacterial load on RNEs in vitro. In vitro model. Staphylococcus aureus, Streptococcus pneumoniae, Pseudomonas aeruginosa, and Haemophilus influenzae contamination was separately induced on RNEs in vitro. Two experimental sets were completed. The RNEs were disinfected using the following protocols: 30-second scrub with antimicrobial soap (ABS) and water, 30-second scrub with 70% isopropyl alcohol (IA), 30-second scrub with ABS followed by 30-second scrub with IA, 30-second scrub with germicidal cloth, isolated 5-minute soak in an enzymatic soap solution, 5- and 10-minute soaks in ortho-phthalaldehyde, 0.55%, solution (Cidex OPA), and isolated 30-second rinse with tap water, all with 30-second precleaning and postcleaning rinses with tap water. Two sets of experiments (experiment sets A and B) were carried out with a 30-second tap water rinse after inoculation of each RNE. This was followed by immediate cleaning in set A and a 1-hour air-dry delay in set B. Otherwise there were no differences in the disinfection protocols between sets for each method noted. Effectiveness of various disinfection protocols in cleaning rigid nasal endoscopes experimentally inoculated with bacteria commonly found in the upper aerodigestive tract. Positive cultures following disinfection indicated ineffective or incomplete disinfection. Most cleaning methods were effective in eliminating S aureus, S pneumoniae, and H influenzae from the scopes following experimental contamination. Continued growth of P aeruginosa was found after all of the disinfection trials in experiment set A with the exception of a 10-minute immersion in Cidex OPA, and in set B except for the 10-minute Cidex OPA immersion and ABS plus IA trials. Most cleaning methods used in our trials appear to properly disinfect RNEs after in vitro inoculation with S aureus, S pneumoniae, and H influenzae. However, it appears that disinfectants may be less effective in cleaning rigid scopes experimentally inoculated with P aeruginosa. There is a paucity of published data regarding cross-contamination during rigid nasal endoscopy, and these results should guide future studies and to some extent practice to avoid iatrogenic spread of contamination.
Viscous Fingering in Deformable Systems
NASA Astrophysics Data System (ADS)
Guan, Jian Hui; MacMinn, Chris
2017-11-01
Viscous fingering is a classical hydrodynamic instability that occurs when an invading fluid is injected into a porous medium or a Hele-Shaw cell that contains a more viscous defending fluid. Recent work has shown that viscous fingering in a Hele-Shaw cell is supressed when the flow cell is deformable. However, the mechanism of suppression relies on a net volumetric expansion of the flow area. Here, we study flow in a novel Hele-Shaw cell consisting of a rigid bottom plate and a flexible top plate that deforms in a way that is volume-conserving. In other words, fluid injection into the flow cell leads to a local expansion of the flow area (outward displacement of the flexible surface) that must be coupled to non-local contraction (inward displacement of the flexible surface). We explore the impact of this volumetric confinement on steady viscous flow and on viscous fingering. We would like to thank EPSRC for the funding for this work.
Compaction of quasi-one-dimensional elastoplastic materials
Shaebani, M. Reza; Najafi, Javad; Farnudi, Ali; Bonn, Daniel; Habibi, Mehdi
2017-01-01
Insight into crumpling or compaction of one-dimensional objects is important for understanding biopolymer packaging and designing innovative technological devices. By compacting various types of wires in rigid confinements and characterizing the morphology of the resulting crumpled structures, here, we report how friction, plasticity and torsion enhance disorder, leading to a transition from coiled to folded morphologies. In the latter case, where folding dominates the crumpling process, we find that reducing the relative wire thickness counter-intuitively causes the maximum packing density to decrease. The segment size distribution gradually becomes more asymmetric during compaction, reflecting an increase of spatial correlations. We introduce a self-avoiding random walk model and verify that the cumulative injected wire length follows a universal dependence on segment size, allowing for the prediction of the efficiency of compaction as a function of material properties, container size and injection force. PMID:28585550
Biocomposites from co-polypropylene and distillers' grains
NASA Astrophysics Data System (ADS)
Zarrinbakhsh, Nima; Mohanty, Amar K.; Misra, Manjusri
2015-05-01
In the present work, we have explored the polymeric composites of distillers' grains with co-polypropylene (co-PP). The effect of maleated-PP compatibilizer on mechanical, thermomechanical and physical properties was evaluated. The composite materials were produced by melt extrusion in a micro-compounder followed by injection molding in a micro-injection machine. The composites were characterized for their tensile, flexural and impact properties. Also, melt flow index and heat deflection temperature were measured. The results showed more than 30 % improvement in modulus when comparing the compatibilized biocomposite with neat co-PP. Also, the strength of the compatibilized biocomposite measured in tensile and flexural tests was comparable to or even better than that of the neat matrix. On the other hand, the reduced flexibility and toughness as a result of compatibilization were in an acceptable range. The biocomposites showed more rigidity at elevated temperatures. The produced distillers' grain biocomposites showed promises for industrial applications.
Beardsley, D; Holman, S; Gantt, R; Robinson, R A; Lindsey, J; Bazaral, M; Stewart, S F; Stevens, R A
1995-08-01
Recent reports of transient neurologic deficits have raised concern about the potential toxicity of single-dose spinal 5% lidocaine in 7.5% dextrose. Two cases of volunteers who experienced minor local sensory deficits after slow (60 s) injections of 2 mL 5% lidocaine via Whitacre needles are described. One case was a result of a double injection because of a "failed" block. It seemed possible that the neurologic deficit in these cases resulted from neurotoxicity associated with maldistribution of local anesthetic. Using an in vitro spinal model, we investigated drug distribution resulting from injections through side-port spinal needles to determine whether the use of these needles could result in high local concentrations of hyperbaric solutions. A spinal canal model was fabricated using human magnetic resonance measurements. The model was placed in a surgical supine position and filled with lactated Ringer's solution to simulate the specific gravity of cerebral spinal fluid at 22 degrees C. A hyperbaric solution of phthalocyanine blue dye and dextrose (SG 1.042), simulating the anesthetic, was injected through three different needles (27-gauge 4 11/16-in. Whitacre, 25-gauge 3 1/2-in. Whitacre, 25-gauge 3 1/2-in. Quincke). Triplicate injections were done at rapid (2 mL/10 s) and slow (2 mL/60 s) rates, with needle side ports oriented in a sacral and cephalad direction. At slow rates of injection, using 27- or 25-gauge sacrally directed Whitacre needles, injections showed evidence of maldistribution with extrapolated peak sacral lidocaine concentrations reaching 2.0%. In contrast, distribution after slow injection through sacrally directed Quincke needles was uniform.(ABSTRACT TRUNCATED AT 250 WORDS)
In ovo feeding of L-arginine alters energy metabolism in post-hatch broilers.
Yu, L L; Gao, T; Zhao, M M; Lv, P A; Zhang, L; Li, J L; Jiang, Y; Gao, F; Zhou, G H
2018-01-01
This study aimed to investigate the effects of in ovo feeding (IOF) of L-arginine (Arg) on energy metabolism in post-hatch broilers. A total of 720 eggs was randomly assigned to 3 treatments: 1) non-injected control group, 2) 0.75% NaCl diluent-injected control group, and 3) 1.0% Arg solution-injected group. At 17.5 d of incubation, 0.6 mL of each solution was injected into the amniotic fluid of each egg of injected groups. After hatching, 80 male chicks were randomly assigned to each treatment group with 8 replicates per group. The results showed that IOF of Arg increased glycogen and glucose concentrations in the liver and pectoral muscle of broilers at hatch (P < 0.05). The plasma glucose and insulin levels were higher in the Arg group than in the non-injected and diluent-injected control groups (P < 0.05). Meanwhile, IOF of Arg enhanced the hepatic glucose-6-phosphatase (G6P) activity at hatch (P < 0.05). There was no difference in hexokinase (HK) or phosphofructokinase (PFK) enzyme activities in the pectoral muscle in all groups. Further, IOF of Arg increased the phosphoenolpyruvate carboxykinase (PEPCK) and fructose-1,6-bisphosphatase (FBP) mRNA expressions at hatch (P < 0.05). In addition, broilers in the Arg group had a higher mRNA expression of glycogen synthase and a lower expression of glycogen phosphorylase in the liver and pectoral muscles than in the non-injected controls at hatch (P < 0.05). In conclusion, IOF of Arg solution enhanced liver and pectoral muscle energy reserves at hatch, which might be considered as an effective strategy for regulating early energy metabolism in broilers. © 2017 Poultry Science Association Inc.
Liposuction: Anaesthesia challenges
Sood, Jayashree; Jayaraman, Lakshmi; Sethi, Nitin
2011-01-01
Liposuction is one of the most popular treatment modalities in aesthetic surgery with certain unique anaesthetic considerations. Liposuction is often performed as an office procedure. There are four main types of liposuction techniques based on the volume of infiltration or wetting solution injected, viz dry, wet, superwet, and tumescent technique. The tumescent technique is one of the most common liposuction techniques in which large volumes of dilute local anaesthetic (wetting solution) are injected into the fat to facilitate anaesthesia and decrease blood loss. The amount of lignocaine injected may be very large, approximately 35-55 mg/kg, raising concerns regarding local anaesthetic toxicity. Liposuction can be of two types according to the volume of solution aspirated: High volume (>4,000 ml aspirated) or low volume (<4,000 ml aspirated). While small volume liposuction may be done under local/monitored anaesthesia care, large-volume liposuction requires general anaesthesia. As a large volume of wetting solution is injected into the subcutaneous tissue, the intraoperative fluid management has to be carefully titrated along with haemodynamic monitoring and temperature control. Assessment of blood loss is difficult, as it is mixed with the aspirated fat. Since most obese patients opt for liposuction as a quick method to lose weight, all concerns related to obesity need to be addressed in a preoperative evaluation. PMID:21808392
Administration of Injectable Vitamin K Orally.
Afanasjeva, Janna
2017-10-01
Background: Vitamin K, or phytonadione, is available in both injectable and oral formulations. Oral vitamin K is available as 5-mg tablets, but the key drawbacks for using vitamin K tablets consist of availability of only 1 dose strength and recent tripling of the product's cost over a 2-year period. An interest exists for utilization of injectable vitamin K via oral route. Method: A literature search was performed on April 26, 2017, to identify any studies describing the use of injectable vitamin K for oral administration. The search involved PubMed and Embase and utilized various combinations of keywords vitamin K , phytonadione , IV , intravenous , injectable , and oral . The results were limited to studies that discussed oral administration of injectable vitamin K. The efficacy of the injectable preparation of vitamin K administered orally was explored in 6 studies and one cost-savings project. Results: Based on the available literature, the administration of injectable vitamin K via oral route is effective and safe. Injectable vitamin K for oral administration can be prepared as an undiluted solution or as a compounded solution. These 2 formulations have different beyond-use dates depending on ingredients used. Conclusion: Information on efficacy and stability of injectable vitamin K formulations prepared for oral administration provides an additional option for health care systems when vitamin K tablets are unavailable or cost-prohibitive to use.
Study on the technology of dual-tube layered injection in ASP flooding
NASA Astrophysics Data System (ADS)
Yang, Ye; Zhang, Yongping; Xu, Dekui; Cai, Meng; Yang, Zhigang; Wang, Hailong; Song, Xingliang
2017-10-01
For the single-tube layered injection technology cannot solve the problem of interlayer pressure difference is greater than 2MPa injection wells, through the development of dual-tube packer, dual-tube injection allocator, downhole plug, the ground pressure regulator and molecular weight regulator. Dual-tube layered injection technology is formed. According to the data of ASP flooding injection wells in the field, the whole well is divided into high permeability and low permeability oil reservoir. Two separate injection channels can be formed by using dual-tube packer and dual-tube injection allocator. Through the use of the ground pressure regulator, the problem of the high permeability layer and low permeability layer of the injection pressure difference is solved. Through the use of the ground molecular weight regulator, the problem that the same molecular weight ASP solution is not suitable for high and low permeability is solved. By replacing the downhole plug, the grouping transformation of some oil layer can be achieved. The experiment and field application of 3 wells results show that: the flow control range is 20m3/d-70m3/d; the max. Throttling differential pressure is 3.5MPa; the viscosity loss rate of solution is less than 5%; and the molecular weight adjusting range is 20%-50%. The utilization degree of oil layer is obviously increased through the use of the dual-tube layered injection technology.
Modification of vortex ring formation using dilute polymer solution
NASA Astrophysics Data System (ADS)
Jordan, Daniel; Krane, Michael; Peltier, Joel; Patterson, Eric; Fontaine, Arnold
2006-11-01
This talk will present the results of an experimental study to determine the effect of dilute polymer solution on the formation of a vortex ring. Experiments were conducted in a large, glass tank, filled with water. Vortex rings were produced by injecting a slug of dilute polymer solution into the tank through a nozzle. The injection was controlled by a prescribed piston motion in the nozzle. For the same piston motion, vortex rings were produced for 3 concentrations of the polymer solution, including one with no polymer. The vortex ring flowfield was measured using DPIV. Differences between the 3 cases of polymer concentration in vortex ring formation time, circulation, size, and convection speed are presented.
NASA Technical Reports Server (NTRS)
Fitz-Coy, Norman; Liu, Ming-Cheng
1995-01-01
A two-phase proportional navigation scheme is developed for the case of two rigid bodies engaged in a rendezvous/docking maneuver. The target vehicle is nonmaneuvering, but does have constant nonzero angular and linear velocities. Under these conditions, it is shown that previously obtained solutions are not applicable. Analytical solutions are obtained leading to relationships between the transverse and LOS navigation constants. It is shown that the transverse navigation constant for the second phase of the maneuver must be 2. Also, initial conditions necessary for rendezvous are presented.
Lu, Minhua; Huang, Shuai; Yang, Xianglong; Yang, Lei; Mao, Rui
2017-01-01
Fluid-jet-based indentation is used as a noncontact excitation technique by systems measuring the mechanical properties of soft tissues. However, the application of these devices has been hindered by the lack of theoretical solutions. This study developed a mathematical model for testing the indentation induced by a fluid jet and determined a semianalytical solution. The soft tissue was modeled as an elastic layer bonded to a rigid base. The pressure of the fluid jet impinging on the soft tissue was assumed to have a power-form function. The semianalytical solution was verified in detail using finite-element modeling, with excellent agreement being achieved. The effects of several parameters on the solution behaviors are reported, and a method for applying the solution to determine the mechanical properties of soft tissues is suggested.
Distribution of Injectate and Sensory-Motor Blockade After Adductor Canal Block.
Gautier, Philippe E; Hadzic, Admir; Lecoq, Jean-Pierre; Brichant, Jean Francois; Kuroda, Maxine M; Vandepitte, Catherine
2016-01-01
The analgesic efficacy reported for the adductor canal block may be related to the spread of local anesthetic outside the adductor canal. Fifteen patients undergoing knee surgery received ultrasound-guided injections of local anesthetic at the level of the adductor hiatus. Sensory-motor block and spread of contrast solution were assessed. Sensation was rated as "markedly diminished" or "absent" in the saphenous nerve distribution and "slightly diminished" in the sciatic nerve territory without motor deficits. Contrast solution was found in the popliteal fossa. The spread of injectate to the popliteal fossa may contribute to the analgesic efficacy of adductor canal block.
Lafferty, Lise; Treloar, Carla; van Breda, Nick; Steele, Maureen; Hiley, Sarah; Flaherty, Ian; Salmon, Allison
2017-09-01
Injection of pharmaceutical opioids (PO) among people who inject drugs has increased in many countries. The common method for preparing PO tablets for injection uses heat, resulting in greater particulate matter and therefore increased risk of local infection risk and damage to veins and organs. A cold preparation process has fewer risks, but this preparation method is not commonly used. This study seeks to explore how people who inject PO learn to prepare injections and how health promotion efforts could influence practice. Between March and December 2013, qualitative interviews were undertaken with 33 clients of Sydney's Medically Supervised Injecting Centre who inject PO tablets regarding sources of knowledge and current preparation methods for injection of POs. Overwhelmingly, the most commonly reported source of knowledge around injection of tablets was others who inject. Most participants reported heating the solution as the quickest way to administer the drug. Attitudes to the use of wheel filters varied, with some participants reporting that they would use the filters if they were shown how, while others reported a number of barriers to using filters, including complexity of use. Harnessing the power of social connections may provide avenues for education about safer injecting of tablets, including the use of wheel filters. Further work is required to debunk myths about the relative potencies of cold versus hot drug solution. Collaborations between harm reduction workers and peer workers would assist in knowledge dissemination regarding safer injecting practices. © 2017 Australasian Professional Society on Alcohol and other Drugs.
NASA Astrophysics Data System (ADS)
Amireghbali, A.; Coker, D.
2018-01-01
Burridge and Knopoff proposed a mass-spring model to explore interface dynamics along a fault during an earthquake. The Burridge and Knopoff (BK) model is composed of a series of blocks of equal mass connected to each other by springs of same stiffness. The blocks also are attached to a rigid driver via another set of springs that pulls them at a constant velocity against a rigid substrate. They studied dynamics of interface for an especial case with ten blocks and a specific set of fault properties. In our study effects of Coulomb and rate-state dependent friction laws on the dynamics of a single block BK model is investigated. The model dynamics is formulated as a system of coupled nonlinear ordinary differential equations in state-space form which lends itself to numerical integration methods, e.g. Runge-Kutta procedure for solution. The results show that the rate and state dependent friction law has the potential of triggering dynamic patterns that are different from those under Coulomb law.
NASA Astrophysics Data System (ADS)
Goryk, A. V.; Koval'chuk, S. B.
2018-05-01
An exact elasticity theory solution for the problem on plane bending of a narrow layered composite cantilever beam by tangential and normal loads distributed on its free end is presented. Components of the stress-strain state are found for the whole layers package by directly integrating differential equations of the plane elasticity theory problem by using an analytic representation of piecewise constant functions of the mechanical characteristics of layer materials. The continuous solution obtained is realized for a four-layer beam with account of kinematic boundary conditions simulating the rigid fixation of its one end. The solution obtained allows one to predict the strength and stiffness of composite cantilever beams and to construct applied analytical solutions for various problems on the elastic bending of layered beams.
Duarte, Patricia C; Paz, Cahuê F R; Oliveira, Alvaro P L; Maróstica, Thairê P; Cota, Leticia O; Faleiros, Rafael R
2017-07-01
To investigate the nociceptive and clinical effects of buffering a lidocaine-epinephrine solution with sodium bicarbonate in caudal epidural block in mares. Prospective randomized controlled trial. Six mixed-breed mares weighing 350-440 kg. Each animal was administered two caudal epidural injections, 72 hours apart, using different solutions prepared immediately before injection. The control solution was 7 mL 2% lidocaine hydrochloride with epinephrine hemitartrate (1:200,000) added to 3 mL sterile water for injection (pH 2.9). The alkalinized solution was 7 mL of lidocaine-epinephrine solution added to 2.3 mL sterile water for injection and 0.7 mL 8.4% sodium bicarbonate (pH 7.4). Nociception was evaluated by response to skin pinching at 31 sites in the sacral region and around the perimeter of the anogenital area (distances of 10, 15 and 20 cm) before, and 5, 10 and 15 minutes after epidural injection, then every 15 minutes until the return of nociception in all evaluated sites. The onset and duration times, and intensity of ataxia (grades 0 to 3) were recorded. The paired t test was used to compare the onset and duration of anesthesia and ataxia (p<0.05). Alkalization of the solution resulted in significant decreases in the average time of onset of loss of nociception in the sacral region (40%) and around the perimeter of the anogenital area extending up to 5 cm (36%) and from 5 to 10 cm (32%) from the anus and vulva. Alkalization also decreased the average duration of ataxia (33%), without affecting the duration and extent of anesthesia or the degree of ataxia. Alkalization of lidocaine-epinephrine solution is advantageous in shortening the duration of ataxia and hastening the onset of anesthesia in areas adjacent to the anogenital area, without reducing the duration of epidural anesthesia, in mares. Copyright © 2017 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia. Published by Elsevier Ltd. All rights reserved.
Ghanem, Mashhour M; Abu-Lafi, Saleh A; Hallak, Hussein O
2013-01-01
A simple, specific, accurate, and stability-indicating method was developed and validated for the quantitative determination of menadione sodium bisulfite in the injectable solution formulation. The method is based on zwitterionic hydrophilic interaction liquid chromatography (ZIC-HILIC) coupled with a photodiode array detector. The desired separation was achieved on the ZIC-HILIC column (250 mm × 4.6 mm, 5 μm) at 25°C temperature. The optimized mobile phase consisted of an isocratic solvent mixture of 200mM ammonium acetate (NH4AC) solution and acetonitrile (ACN) (20:80; v/v) pH-adjusted to 5.7 by glacial acetic acid. The mobile phase was fixed at 0.5 ml/min and the analytes were monitored at 261 nm using a photodiode array detector. The effects of the chromatographic conditions on the peak retention, peak USP tailing factor, and column efficiency were systematically optimized. Forced degradation experiments were carried out by exposing menadione sodium bisulfite standard and the injectable solution formulation to thermal, photolytic, oxidative, and acid-base hydrolytic stress conditions. The degradation products were well-resolved from the main peak and the excipients, thus proving that the method is a reliable, stability-indicating tool. The method was validated as per ICH and USP guidelines (USP34/NF29) and found to be adequate for the routine quantitative estimation of menadione sodium bisulfite in commercially available menadione sodium bisulfite injectable solution dosage forms.
THE REMOVAL OF CARTILAGE MATRIX, IN VIVO, BY PAPAIN
McCluskey, Robert T.; Thomas, Lewis
1958-01-01
The intravenous injection of crystalline papain into young rabbits results in depletion of cartilage matrix throughout the body, with loss of rigidity and collapse of the ears, provided the enzyme is inactivated by oxidation or sulfhydryl blocking agents prior to administration. Cysteine-activated crystalline papain, when injected intravenously, produces little or no change in cartilage. The changes which occur in cartilage following an injection of inactivated crystalline papain are indistinguishable from those produced by crude papain. Activation of crude papain by cysteine prior to injection results in loss of its capacity to produce in vivo changes in cartilage. The progressive changes which take place in cartilage in vivo also occur in vitro in isolated rabbit ears removed shortly after an injection of crude papain or inactivated crystalline papain. In vitro ear collapse occurs rapidly at 37°C. and does not occur at 4°C. Collapse is enhanced by exposing the cartilage to cysteine and prevented by exposure to iodoacetamide or p-chloromercuribenzoate. The direct action of crystalline papain on plates of normal cartilage, in vitro, results in the same gross and histological changes which were observed in vivo. The direct action is accelerated by cysteine and inhibited by iodoacetamide or p-chloromercuribenzoate. The intravenous injection of iodoacetamide-treated bromelin produces the same in vivo changes in cartilage as papain. Untreated bromelin has no demonstrable effect on cartilage. It is suggested that the reason for the failure of activated papain to enter cartilage, after being injected intravenously, is that it probably reacts with a substrate or substrates in the blood. Oxidized or otherwise inactivated papain, in contrast, is readily taken up by cartilage and there converted to its active form. PMID:13575673
Ferrieri, Richard A.; Schlyer, David J.; Alexoff, David
1996-01-09
A handling and processing apparatus for preparing Oxygen-15 labeled water (H.sub.2 [.sup.15 O]) in injectable form for use in Positron Emission Tomography from preferably H.sub.2 [.sup.15 O] produced by irradiating a flowing gas target of nitrogen and hydrogen. The apparatus includes a collector for receiving and directing a gas containing H.sub.2 [.sup.15 O] gas and impurities, mainly ammonia (NH.sub.3) gas into sterile water to trap the H.sub.2 [.sup.15 O] and form ammonium (NH.sub.4.sup.+) in the sterile water. A device for displacing the sterile water containing H.sub.2 [.sup.15 O] and NH.sub.4.sup.+ through a cation resin removes NH.sub.4.sup.+ from the sterile water. A device for combining the sterile water containing H.sub.2 [.sup.15 O] with a saline solution produces an injectable solution. Preferably, the apparatus includes a device for delivering the solution to a syringe for injection into a patient. Also, disclosed is a method for preparing H.sub.2 [.sup.15 O] in injectable form for use in Positron Emission Tomography in which the method neither requires isotopic exchange reaction nor application of high temperature.
Niu, Xiaogang; Brüschweiler-Li, Lei; Davulcu, Omar; Skalicky, Jack J.; Brüschweiler, Rafael; Chapman, Michael S.
2010-01-01
The phosphagen kinase family, including creatine and arginine kinases, catalyze the reversible transfer of a “high energy” phosphate between ATP and a phospho-guanidino substrate. They have become a model for the study of both substrate-induced conformational change and intrinsic protein dynamics. Prior crystallographic studies indicated large substrate-induced domain rotations, but differences among a recent set of arginine kinase structures was interpreted as a plastic deformation. Here, the structure of Limulus substrate-free arginine kinase is refined against high resolution crystallographic data and compared quantitatively with NMR chemical shifts and residual dipolar couplings (RDCs). This demonstrates the feasibility of this type of RDC analysis of proteins that are large by NMR standards (42 kDa), and illuminates the solution structure, free from crystal-packing constraints. Detailed comparison of the 1.7 Å resolution substrate-free crystal structure against the 1.2 Å transition state analog complex shows large substrate-induced domain motions which can be broken down into movements of smaller quasi-rigid bodies. The solution state structure of substrate-free arginine kinase is most consistent with an equilibrium of substrate-free and –bound structures, with the substrate-free form dominating, but with varying displacements of the quasi-rigid groups. Rigid-group rotations evident from the crystal structures are about axes previously associated with intrinsic millisecond dynamics using NMR relaxation dispersion. Thus, “substrate-induced” motions are along modes that are intrinsically flexible in the substrate-free enzyme, and likely involve some degree of conformational selection. PMID:21075117
Laforge, François O; Carpino, James; Rotenberg, Susan A; Mirkin, Michael V
2007-07-17
The ability to manipulate ultrasmall volumes of liquids is essential in such diverse fields as cell biology, microfluidics, capillary chromatography, and nanolithography. In cell biology, it is often necessary to inject material of high molecular weight (e.g., DNA, proteins) into living cells because their membranes are impermeable to such molecules. All techniques currently used for microinjection are plagued by two common problems: the relatively large injector size and volume of injected fluid, and poor control of the amount of injected material. Here we demonstrate the possibility of electrochemical control of the fluid motion that allows one to sample and dispense attoliter-to-picoliter (10(-18) to 10(-12) liter) volumes of either aqueous or nonaqueous solutions. By changing the voltage applied across the liquid/liquid interface, one can produce a sufficient force to draw solution inside a nanopipette and then inject it into an immobilized biological cell. A high success rate was achieved in injections of fluorescent dyes into cultured human breast cells. The injection of femtoliter-range volumes can be monitored by video microscopy, and current/resistance-based approaches can be used to control injections from very small pipettes. Other potential applications of the electrochemical syringe include fluid dispensing in nanolithography and pumping in microfluidic systems.
Laforge, François O.; Carpino, James; Rotenberg, Susan A.; Mirkin, Michael V.
2007-01-01
The ability to manipulate ultrasmall volumes of liquids is essential in such diverse fields as cell biology, microfluidics, capillary chromatography, and nanolithography. In cell biology, it is often necessary to inject material of high molecular weight (e.g., DNA, proteins) into living cells because their membranes are impermeable to such molecules. All techniques currently used for microinjection are plagued by two common problems: the relatively large injector size and volume of injected fluid, and poor control of the amount of injected material. Here we demonstrate the possibility of electrochemical control of the fluid motion that allows one to sample and dispense attoliter-to-picoliter (10−18 to 10−12 liter) volumes of either aqueous or nonaqueous solutions. By changing the voltage applied across the liquid/liquid interface, one can produce a sufficient force to draw solution inside a nanopipette and then inject it into an immobilized biological cell. A high success rate was achieved in injections of fluorescent dyes into cultured human breast cells. The injection of femtoliter-range volumes can be monitored by video microscopy, and current/resistance-based approaches can be used to control injections from very small pipettes. Other potential applications of the electrochemical syringe include fluid dispensing in nanolithography and pumping in microfluidic systems. PMID:17620612
Designing Fault-Injection Experiments for the Reliability of Embedded Systems
NASA Technical Reports Server (NTRS)
White, Allan L.
2012-01-01
This paper considers the long-standing problem of conducting fault-injections experiments to establish the ultra-reliability of embedded systems. There have been extensive efforts in fault injection, and this paper offers a partial summary of the efforts, but these previous efforts have focused on realism and efficiency. Fault injections have been used to examine diagnostics and to test algorithms, but the literature does not contain any framework that says how to conduct fault-injection experiments to establish ultra-reliability. A solution to this problem integrates field-data, arguments-from-design, and fault-injection into a seamless whole. The solution in this paper is to derive a model reduction theorem for a class of semi-Markov models suitable for describing ultra-reliable embedded systems. The derivation shows that a tight upper bound on the probability of system failure can be obtained using only the means of system-recovery times, thus reducing the experimental effort to estimating a reasonable number of easily-observed parameters. The paper includes an example of a system subject to both permanent and transient faults. There is a discussion of integrating fault-injection with field-data and arguments-from-design.
Spindeldreier, Kirsten; Thiesen, Judith; Lipp, Hans-Peter; Krämer, Irene
2014-06-01
The aim of this study was to determine the stability of commercially available eribulin mesylate containing injection solution as well as diluted ready-to-administer solutions stored under refrigeration or at room temperature. Stability was studied by a novel developed stability-indicating reversed-phase high-performance liquid chromatography (RP-HPLC) assay with ultraviolet detection (detection wavelength 200 nm). Triplicate test solutions of eribulin mesylate containing injection concentrate (0.5 mg/mL) and with 0.9% sodium chloride solution diluted ready-to-administer preparations (0.205 mg/mL eribulin mesylate in polypropylene (PP) syringes, 0.020 mg/mL eribulin mesylate in polypropylene/polyethylene (PE) bags) were stored protected from light either at room temperature (25) or under refrigeration (2-8). Samples were withdrawn on day 0 (initial), 1, 3, 5, 7, 14, 21 and 28 of storage and assayed. Physical stability was determined by measuring the pH value once a week and checking for visible precipitations or colour changes. The stability tests revealed that concentrations of eribulin mesylate remained unchanged over a period of 28 days irrespective of concentration, container material or storage temperature. Neither colour changes nor visible particles have been observed. The pH value varied slightly over time but remained in the stability favourable range of 5-9. Eribulin mesylate injection (0.5 mg/mL) is physico-chemically stable over a period of 28 days after first puncture of the vial. After dilution with 0.9% NaCl vehicle solution, ready-to-administer eribulin mesylate injection solutions (0.205 mg/mL in PP syringe) and infusion solutions (0.02 mg/mL in prefilled PP/PE bags) are physico-chemically stable for a period of at least four weeks either refrigerated or stored at room temperature. For microbiological reasons storage under refrigeration is recommended.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Feng, E-mail: chenfengmath@163.com, E-mail: hanyc@jlu.edu.cn; Han, Yuecai, E-mail: chenfengmath@163.com, E-mail: hanyc@jlu.edu.cn
2013-12-15
The existence of time-periodic stochastic motions of an incompressible fluid is obtained. Here the fluid is subject to a time-periodic body force and an additional time-periodic stochastic force that is produced by a rigid body moves periodically stochastically with the same period in the fluid.
Solution of the Wang Chang-Uhlenbeck equation for molecular hydrogen
NASA Astrophysics Data System (ADS)
Anikin, Yu. A.
2017-06-01
Molecular hydrogen is modeled by numerically solving the Wang Chang-Uhlenbeck equation. The differential scattering cross sections of molecules are calculated using the quantum mechanical scattering theory of rigid rotors. The collision integral is computed by applying a fully conservative projection method. Numerical results for relaxation, heat conduction, and a one-dimensional shock wave are presented.
Spacecraft detumbling through energy dissipation
NASA Technical Reports Server (NTRS)
Fitz-Coy, Norman; Chatterjee, Anindya
1993-01-01
The attitude motion of a tumbling, rigid, axisymmetric spacecraft is considered. A methodology for detumbling the spacecraft through energy dissipation is presented. The differential equations governing this motion are stiff, and therefore an approximate solution, based on the variation of constants method, is developed and utilized in the analysis of the detumbling strategy. Stability of the detumbling process is also addressed.
Intelligent Control of Flexible-Joint Robotic Manipulators
NASA Technical Reports Server (NTRS)
Colbaugh, R.; Gallegos, G.
1997-01-01
This paper considers the trajectory tracking problem for uncertain rigid-link. flexible.joint manipulators, and presents a new intelligent controller as a solution to this problem. The proposed control strategy is simple and computationally efficient, requires little information concerning either the manipulator or actuator/transmission models and ensures uniform boundedness of all signals and arbitrarily accurate task-space trajectory tracking.
DOE Office of Scientific and Technical Information (OSTI.GOV)
none,
2011-11-01
PNNL and Calcs Plus helped the South Sarasota County Florida Habitat for Humanity retrofit a 1978 single-story home by stripping old drywall, air sealing concrete block walls, and installing rigid insulation, furring strips, and new drywall. The attic was sealed and insulated with spray foam to house a new heat pump.
Antagonistic actuation and stiffness control in soft inflatable robots
NASA Astrophysics Data System (ADS)
Althoefer, Kaspar
2018-06-01
Soft robots promise solutions for a wide range of applications that cannot be achieved with traditional, rigid-component robots. A key challenge is the creation of robotic structures that can vary their stiffness at will, for example, by using antagonistic actuators, to optimize their interaction with the environment and be able to exert high forces.
Large-angle slewing maneuvers for flexible spacecraft
NASA Technical Reports Server (NTRS)
Chun, Hon M.; Turner, James D.
1988-01-01
A new class of closed-form solutions for finite-time linear-quadratic optimal control problems is presented. The solutions involve Potter's solution for the differential matrix Riccati equation, which assumes the form of a steady-state plus transient term. Illustrative examples are presented which show that the new solutions are more computationally efficient than alternative solutions based on the state transition matrix. As an application of the closed-form solutions, the neighboring extremal path problem is presented for a spacecraft retargeting maneuver where a perturbed plant with off-nominal boundary conditions now follows a neighboring optimal trajectory. The perturbation feedback approach is further applied to three-dimensional slewing maneuvers of large flexible spacecraft. For this problem, the nominal solution is the optimal three-dimensional rigid body slew. The perturbation feedback then limits the deviations from this nominal solution due to the flexible body effects. The use of frequency shaping in both the nominal and perturbation feedback formulations reduces the excitation of high-frequency unmodeled modes. A modified Kalman filter is presented for estimating the plant states.
77 FR 39390 - Implantation or Injectable Dosage Form New Animal Drugs; Maropitant; Tildipirosin
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-03
...., Summit, Injectable the treatment NJ 07901. Solution. of bovine respiratory disease (BRD) in beef and non-lactating dairy cattle; and for the control of respiratory disease in beef and non- lactating dairy cattle... subcutaneous injection in the neck. (ii) Indications for use. For the treatment of bovine respiratory disease...
Crack identification for rigid pavements using unmanned aerial vehicles
NASA Astrophysics Data System (ADS)
Bahaddin Ersoz, Ahmet; Pekcan, Onur; Teke, Turker
2017-09-01
Pavement condition assessment is an essential piece of modern pavement management systems as rehabilitation strategies are planned based upon its outcomes. For proper evaluation of existing pavements, they must be continuously and effectively monitored using practical means. Conventionally, truck-based pavement monitoring systems have been in-use in assessing the remaining life of in-service pavements. Although such systems produce accurate results, their use can be expensive and data processing can be time consuming, which make them infeasible considering the demand for quick pavement evaluation. To overcome such problems, Unmanned Aerial Vehicles (UAVs) can be used as an alternative as they are relatively cheaper and easier-to-use. In this study, we propose a UAV based pavement crack identification system for monitoring rigid pavements’ existing conditions. The system consists of recently introduced image processing algorithms used together with conventional machine learning techniques, both of which are used to perform detection of cracks on rigid pavements’ surface and their classification. Through image processing, the distinct features of labelled crack bodies are first obtained from the UAV based images and then used for training of a Support Vector Machine (SVM) model. The performance of the developed SVM model was assessed with a field study performed along a rigid pavement exposed to low traffic and serious temperature changes. Available cracks were classified using the UAV based system and obtained results indicate it ensures a good alternative solution for pavement monitoring applications.
Simulators for training in ultrasound guided procedures.
Farjad Sultan, Syed; Shorten, George; Iohom, Gabrielle
2013-06-01
The four major categories of skill sets associated with proficiency in ultrasound guided regional anaesthesia are 1) understanding device operations, 2) image optimization, 3) image interpretation and 4) visualization of needle insertion and injection of the local anesthetic solution. Of these, visualization of needle insertion and injection of local anaesthetic solution can be practiced using simulators and phantoms. This survey of existing simulators summarizes advantages and disadvantages of each. Current deficits pertain to the validation process.
NASA Technical Reports Server (NTRS)
Yoder, C. F.
1979-01-01
Orbit-orbit and spin-orbit gravitational resonances are analyzed using the model of a rigid pendulum subject to both a time-dependent periodic torque and a constant applied torque. First, a descriptive model of passage through resonance is developed from an examination of the polynomial equation that determines the extremes of the momentum variable. From this study, a probability estimate for capture into libration is derived. Second, a lowest order solution is constructed and compared with the solution obtained from numerical integration. The steps necessary to systematically improve this solution are also discussed. Finally, the effect of a dissipative term in the pendulum equation is analyzed.
Effects of Alcohol Injection in Rat Sciatic Nerve
Mazoch, Mathew J.; Cheema, Gulraiz A.; Suva, Larry J.; Thomas, Ruth L.
2015-01-01
Background Previous studies have shown that the injection of dehydrated alcohol has been successful for the treatment of Morton's neuroma in the foot. In this study, we determined the cellular effect of injection of alcohol into and around the sciatic nerve of rats, and measured the extent of cell necrosis and/or any associated histologic or inflammatory changes. Methods Twenty-two male (~375g) Wistar rats were randomized into two groups each receiving alcohol injections into or around the sciatic nerve after nerve exposure under sterile technique. Group 1 rats were injected with a 0.5ml solution of 0.5% Marcaine in the left sciatic nerve as a control group. In the right sciatic nerve a 0.5ml solution of 4% ethanol with 0.5% Marcaine was injected. Group 2 rats received 0.5ml of 20%ethanol with 0.5% Marcaine injected into the left sciatic nerve and 0.5 ml of 30% ethanol with 0.5% Marcaine injected into the right sciatic nerve. In each group, the rats were placed in 3 subgroups: intraneural, perineural, perimuscular injections. All rats were sacrificed and tissue harvested for histologic evaluation at day 10 post injection. Results No evidence of alcohol-associated cell necrosis, apoptosis or apparent inflammation was observed in histologic specimens of any injected nerves, perineural tissue, or muscles in controls or experimental groups regardless of concentration of ethanol injected on day 10. Conclusion We concluded that alcohol injection (≤30% ethanol) into and/or around the sciatic nerve or the adjacent muscle of rats has no histologic evidence of necrosis or inflammation to the nerve or surrounding tissue. There was no observable histological change in apoptosis, or cell number, in response to the alcohol injection. PMID:25097192
Transport toward a well in highly heterogeneous aquifer
NASA Astrophysics Data System (ADS)
Di Dato, Mariaines; de Barros, Felipe P. J.; Bellin, Alberto; Fiori, Aldo
2017-04-01
Solute transport toward a well is a challenging subject in subsurface hydrology since the complexity of the mathematical model is tremendously increased by the non-uniformity of the mean flow and heterogeneity of the formation. Up to date, analytical solutions for such flow configurations are limited to low heterogeneous conditions. On the other hand, numerical simulations in 3D highly heterogeneous formations are computationally expensive and plagued by numerical errors. In this work we propose an analytical solution for the Breakthrough Curve (BTC) at the well for an instantaneous linear injection across the aquifer's thickness for any degree of heterogeneity of the porous medium. Our solution makes use of the Multi Indicator Model-Self Consistent Approximation (MIMSCA), by which the aquifer is conceptualized as an ensemble of blocks of constant hydraulic conductivity K randomly drawn from a lognormal distribution. In order to apply MIMSCA, we assume the flow as locally uniform, given that K is uniform within the block. With this approximation, the travel time to the well is equal to the superposition of the time spent by the solute particle within each block. We emphasize that, despite the approximations introduced, the model is able to reproduce the laboratory experiment of [1] without the need to fit any transport parameters. In this work, we present results for two different injection modes: a resident injection (e.g., residual DNAPL) and a flux proportional injection (e.g., leakage from a passive well). The proposed methodology allows to quantify the BTC at the well as a function of few parameters such as the injection mode and the statistical structure of the aquifer (geometric mean, variance and integral scale of the hydraulic conductivity field). Results illustrate that the release condition has a strong impact on the shape of the BTC. Furthermore, the difference between different injection modes increases with the heterogeneity of the K-field. The importance of the both injection mode and heterogeneity degree are also elucidated on the early and late solute arrival times at the well. Finally, we show how travel times become ergodic only for very thick aquifers, even in case of mild heterogeneity. We emphasize that the present framework has a practical validity, giving an affordable, although approximated, first estimation of mass arrival at an extraction well. References [1] Fernàndez-Garcia, D., T. H. Illangasekare, and H. Rajaram (2004), Conservative and sorptive forced-gradient and uniform flow tracer tests in a three-dimensional laboratory test aquifer, Water Resour. Res., 40, W10103, doi:10.1029/2004WR003112.
75 FR 54018 - Implantation or Injectable Dosage Form New Animal Drugs; Florfenicol and Flunixin
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-03
... respiratory disease (BRD) pathogens for which use of an injectable solution containing florfenicol and.... For treatment of bovine respiratory disease (BRD) associated with Mannheimia haemolytica, Pasteurella...
Numerical simulation of transverse fuel injection
NASA Technical Reports Server (NTRS)
Mao, Marlon; Riggins, David W.; Mcclinton, Charles R.
1991-01-01
A review of recent work at NASA Langley Research Center to compare the predictions of transverse fuel injector flow fields and mixing performance with experimental results is presented. Various cold (non-reactive) mixing studies were selected for code calibration which include the effects of boundary layer thickness and injection angle for sonic hydrogen injection into supersonic air. Angled injection of helium is also included. This study was performed using both the three-dimensional elliptic and the parabolized Navier-Stokes (PNS) versions of SPARK. Axial solution planes were passed from PNS to elliptic and elliptic to PNS in order to efficiently generate solutions. The PNS version is used both upstream and far downstream of the injector where the flow can be considered parabolic in nature. The comparisons are used to identify experimental deficiencies and computational procedures to improve agreement.
Stabile, P; Reader, A; Gallatin, E; Beck, M; Weaver, J
2000-04-01
The purpose of this study was to determine the anesthetic efficacy and heart rate effects of an intraosseous (IO) injection of 1.5% etidocaine with 1:200,000 epinephrine after an inferior alveolar nerve block. In a repeated-measures designed study, 48 subjects randomly received 2 combinations of injections at 2 separate appointments. The combinations were an inferior alveolar nerve (IAN) block (with 3% mepivacaine) + IO injection with 1.8 mL of 1.5% etidocaine hydrochloride containing 1:200,000 epinephrine, and an IAN + mock IO injection. The first molar was blindly tested with a pulp tester at 2-minute cycles for 60 minutes after the injection. Anesthesia was considered successful when 2 consecutive 80 readings (no subject response) were obtained. Heart rate (pulse rate) was measured with a pulse oximeter. Lip numbness occurred in 100% of the subjects with both the techniques. For the first molar, anesthetic success for the IAN + mock IO and the IAN + IO etidocaine hydrochloride groups, respectively, were 81% and 100%. The differences were significant (P <.05) when the IAN + IO etidocaine hydrochloride technique was compared with the IAN + mock IO. A mean increase in heart rate of 32 beats/min occurred in 90% of the subjects with the IO injection of the etidocaine hydrochloride solution. In 89% of these subjects, the heart rate returned to within 5 beats of baseline values 4 minutes or less after solution deposition. The IO injection of 1.8 mL of 1.5% etidocaine hydrochloride with 1:200,000 epinephrine, when used to augment an inferior alveolar nerve block, significantly increased anesthetic success in the first molar. The majority of subjects receiving the IO injection of the etidocaine hydrochloride solution had a transient increase in heart rate.
Solution formulation development of a VEGF inhibitor for intravitreal injection.
Marra, Michelle T; Khamphavong, Penney; Wisniecki, Peter; Gukasyan, Hovhannes J; Sueda, Katsuhiko
2011-03-01
PF-00337210 is a potent, selective small molecule inhibitor of VEGFRs and has been under consideration for the treatment of age-related macular degeneration. An ophthalmic solution formulation intended for intravitreal injection was developed. This formulation was designed to maximize drug properties such that the formulation would precipitate upon injection into the vitreous for sustained delivery. As a parenteral formulation with additional constraints dictated by this specialized delivery route, multiple features were balanced in order to develop a successful formulation. Some of these considerations included low dosing volumes (≤0.1 mL), a limited repertoire of safe excipients for intravitreal injection, and the unique physical chemical properties of the drug. The aqueous solubility as a function of pH was characterized, buffer stressing studies to select the minimal amount of buffer were conducted, and both chemical and physical stability studies were executed. The selected formulation consisted of an isotonic solution comprised of PF-00337210 free base in a citrate-buffered vehicle containing NaCl for tonicity. The highest strength for regulatory toxicology studies was 60 mg/mL. The selected formulation exhibited sufficient chemical stability upon storage with no precipitation, and acceptable potency and recovery through an intravitreal dosing syringe. Formulation performance was simulated by precipitation experiments using extracted vitreous humor. In simulated injection experiments, PF-00337210 solutions reproducibly precipitated upon introduction to the vitreous so that a depot was formed. To our knowledge, this is the first time that a nonpolymeric in situ-forming depot formulation has been developed for intravitreal delivery, with the active ingredient as the precipitating agent. © 2011 American Association of Pharmaceutical Scientists
Noninvasive assessment of aorta-coronary saphenous vein bypass graft patency using thermocouple.
Tanimoto, Y; Watanabe, T; Endo, M; Hayashi, H
1978-03-01
Noninvasive monitoring of patency of aorta-coronary bypass grafts can be achieved with reasonable accuracy using the thermocouple. This method is consisted of attaching the thermocouple to the surface of grafted vein during surgery and judging the patency by rapid injection of iced solution into peripheral vein. Patient grafted vein will show the thermal change after injecting iced solution. On the contrary, occluded graft will show no thermal change. As this thermal curve is a thermodilution curve by a single injection and is measured from the outside of the vessel, thermal change depends on the temperature and the quantity of the injected solution, cardiac output, body temperature, and loss of indicator temperature along the way to the thermocouple. When the grafted vein is patent, the same thermal curves are recorded regardless of the amount of the flow, and zero flow resulted in disappearance of curve. Initially, the method was evaluated in dogs and the appropriateness was verified. Subsequently, this method was applied to 16 vein grafts of 12 patients undergoing aorta-coronary bypass surgery. Ten or 15 ml of iced solution was injected through inferior vena cava or antecubital vein and the thermal change of the grafted vein was recorded for 1-4 weeks after the operation. Fourteen grafted veins were judged to be patent and 2 were occluded. The comparison of the results by this method with coronary angiography undergone at 4 weeks after the operation showed no false positive case but 1 false negative case. This extravascular observation of the thermodilution curve is a convenient method for judging whether vein graft is patent or not.
Nashida, Norihiro; Satoh, Wataru; Fukuda, Junji; Suzuki, Hiroaki
2007-06-15
An integrated microfluidic device with injecting, flushing, and sensing functions was realized using valves that operate based on direct electrowetting. The device consisted of two substrates: a glass substrate with driving and sensing electrodes and a poly(dimethylsiloxane) (PDMS) substrate. Microfluidic transport was achieved using the spontaneous movement of solutions in hydrophilic flow channels formed with a dry-film photoresist layer. The injection and flushing of solutions were controlled by gold working electrodes, which functioned as valves. The valves were formed either in the channels or in a through-hole in the glass substrate. To demonstrate the system's applicability to an immunoassay, the detection of immobilized antigens was performed as a partial simulation of a sandwich immunoassay. Human alpha-fetoprotein (AFP) or an anti-human AFP antibody was immobilized on a platinum working electrode in the chamber using a plasma-polymerized film (PPF). By applying a potential to the injection valves, necessary solutions were injected one by one through the channels into a reaction chamber at the center of the chip and incubated for reasonable periods of time. The solutions were then flushed through the flushing valve and absorbed in a filter paper placed under the device. After incubation with the corresponding antibodies labeled with glucose oxidase (GOD), electrochemical detection was conducted. In both cases, the obtained current depended on the amount of immobilized antigen. The calibration curves were sigmoidal, and the detection limit was 0.1 ng. The developed microfluidic system could potentially be a fundamental component for a micro immunoassay of the next generation.
Rutherford, Kimberley D; Kavanagh, Katherine; Parham, Kourosh
2011-03-01
To determine whether mupirocin (440 µg/mL) and vancomycin otic drops (25 mg/mL) show evidence of ototoxicity in CBA/J mice immediately following a 7-day course of daily intratympanic (IT) injections and 1 month following treatment. Nonrandomized controlled trial. Academic hospital laboratory. Twenty CBA/J mice. Mean auditory brainstem response (ABR) thresholds increased in all drug- and saline-treated ears immediately after 7 days of IT injections but returned to baseline for most stimulus frequencies by 30 days later. This finding appeared to be correlated with the presence and subsequent resolution of tympanic membrane (TM) perforations and granulation tissue at the injection sites. Mupirocin-treated ears showed no significant difference in ABR thresholds compared to saline-treated ears. No significant differences were noted between vancomycin- and saline-treated ears, but there was a significant interaction between testing day and stimulus frequency (P < .001). Further analysis revealed that ABR thresholds at 32 kHz remained significantly elevated in vancomycin-treated mice despite the resolution of TM perforations and granulation tissue 30 days after completion of IT injections (95% confidence interval, -13.5 to -5.5, P < .01). Although IT application of mupirocin solution (440 µg/mL) caused no significant change in the ABR thresholds in a murine model, vancomycin solution (25 mg/mL) resulted in high-frequency threshold elevations in both the ear directly injected and the contralateral ear. Mupirocin solution may be beneficial in managing otitis externa and media caused by resistant pathogens. Further studies of ototopical vancomycin are needed to define parameters governing its safe use.
POISON SPIDER FIELD CHEMICAL FLOOD PROJECT, WYOMING
DOE Office of Scientific and Technical Information (OSTI.GOV)
Douglas Arnell; Malcolm Pitts; Jie Qi
2004-11-01
A reservoir engineering and geologic study concluded that approximate 7,852,000 bbls of target oil exits in Poison Spider. Field pore volume, OOIP, and initial oil saturation are defined. Potential injection water has a total dissolved solids content of 1,275 mg/L with no measurable divalent cations. If the Lakota water consistently has no measurable cations, the injection water does not require softening to dissolve alkali. Produced water total dissolved solids were 2,835 mg/L and less than 20 mg/L hardness as the sum of divalent cations. Produced water requires softening to dissolve chemicals. Softened produced water was used to dissolve chemicals inmore » these evaluations. Crude oil API gravity varies across the field from 19.7 to 22.2 degrees with a dead oil viscosity of 95 to 280 cp at 75 F. Interfacial tension reductions of up to 21,025 fold (0.001 dyne/cm) were developed with fifteen alkaline-surfactant combinations at some alkali concentration. An additional three alkaline-surfactant combinations reduced the interfacial tension greater than 5,000 fold. NaOH generally produced the lowest interfacial tension values. Interfacial tension values of less than 0.021 dyne/cm were maintained when the solutions were diluted with produced water to about 60%. Na{sub 2}CO{sub 3} when mixed with surfactants did not reduce interfacial tension values to levels at which incremental oil can be expected. NaOH without surfactant interfacial tension reduction is at a level where some additional oil might be recovered. Most of the alkaline-surfactant-polymer solutions producing ultra low interfacial tension gave type II- phase behavior. Only two solutions produced type III phase behavior. Produced water dilution resulted in maintenance of phase type for a number of solutions at produced water dilutions exceeding 80% dilution. The average loss of phase type occurred at 80% dilution. Linear corefloods were performed to determine relative permeability end points, chemical-rock compatibility, polymer injectivity, dynamic chemical retention by rock, and recommended injected polymer concentration. Average initial oil saturation was 0.796 Vp. Produced water injection recovered 53% OOIP leaving an average residual oil saturation of 0.375 Vp. Poison Spider rock was strongly water-wet with a mobility ratio for produced water displacing the 280 cp crude oil of 8.6. Core was not sensitive to either alkali or surfactant injection. Injectivity increased 60 to 80% with alkali plus surfactant injection. Low and medium molecular weight polyacrylamide polymers (Flopaam 3330S and Flopaam 3430S) dissolved in either an alkaline-surfactant solution or softened produced water injected and flowed through Poison Spider rock. Recommended injected polyacrylamide concentration is 2,100 mg/L for both polymers for a unit mobility ratio. Radial corefloods were performed to evaluate oil recovery efficiency of different chemical solutions. Waterflood oil recovery averaged 46.4 OOIP and alkaline-surfactant-polymer flood oil recovery averaged an additional 18.1% OIP for a total of 64.6% OOIP. Oil cut change due to injection of a 1.5 wt% Na{sub 2}CO{sub 3} plus 0.05 wt% Petrostep B-100 plus 0.05 wt% Stepantan AS1216 plus 2100 mg/L Flopaam 3430S was from 2% to a peak of 23.5%. Additional study might determine the impact on oil recovery of a lower polymer concentration. An alkaline-surfactant-polymer flood field implementation outline report was written.« less
Field Validation of Supercritical CO 2 Reactivity with Basalts
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGrail, B. Peter; Schaef, Herbert T.; Spane, Frank A.
2017-01-10
Continued global use of fossil fuels places a premium on developing technology solutions to minimize increases in atmospheric CO 2 levels. CO 2 storage in reactive basalts might be one of these solutions by permanently converting injected gaseous CO 2 into solid carbonates. Herein we report results from a field demonstration where ~1000 MT of CO 2 was injected into a natural basalt formation in Eastern Washington State. Following two years of post-injection monitoring, cores were obtained from within the injection zone and subjected to detailed physical and chemical analysis. Nodules found in vesicles throughout the cores were identified asmore » the carbonate mineral, ankerite Ca[Fe, Mg, Mn](CO 3) 2. Carbon isotope analysis showed the nodules are chemically distinct as compared with natural carbonates present in the basalt and clear correlation with the isotopic signature of the injected CO 2. These findings provide field validation of rapid mineralization rates observed from years of laboratory testing with basalts.« less
NASA Astrophysics Data System (ADS)
Ogren, Ryan M.
For this work, Hybrid PSO-GA and Artificial Bee Colony Optimization (ABC) algorithms are applied to the optimization of experimental diesel engine performance, to meet Environmental Protection Agency, off-road, diesel engine standards. This work is the first to apply ABC optimization to experimental engine testing. All trials were conducted at partial load on a four-cylinder, turbocharged, John Deere engine using neat-Biodiesel for PSO-GA and regular pump diesel for ABC. Key variables were altered throughout the experiments, including, fuel pressure, intake gas temperature, exhaust gas recirculation flow, fuel injection quantity for two injections, pilot injection timing and main injection timing. Both forms of optimization proved effective for optimizing engine operation. The PSO-GA hybrid was able to find a superior solution to that of ABC within fewer engine runs. Both solutions call for high exhaust gas recirculation to reduce oxide of nitrogen (NOx) emissions while also moving pilot and main fuel injections to near top dead center for improved tradeoffs between NOx and particulate matter.
Numerical study on injection parameters optimization of thin wall and biodegradable polymers parts
NASA Astrophysics Data System (ADS)
Santos, C.; Mendes, A.; Carreira, P.; Mateus, A.; Malça, C.
2017-07-01
Nowadays, the molds industry searches new markets, with diversified and added value products. The concept associated to the production of thin walled and biodegradable parts mostly manufactured by injection process has assumed a relevant importance due to environmental and economic factors. The growth of a global consciousness about the harmful effects of the conventional polymers in our life quality associated with the legislation imposed, become key factors for the choice of a particular product by the consumer. The target of this work is to provide an integrated solution for the injection of parts with thin walls and manufactured using biodegradable materials. This integrated solution includes the design and manufacture processes of the mold as well as to find the optimum values for the injection parameters in order to become the process effective and competitive. For this, the Moldflow software was used. It was demonstrated that this computational tool provides an effective responsiveness and it can constitute an important tool in supporting the injection molding of thin-walled and biodegradable parts.
Preparation and evaluation of Lu-177 phytate Complex for Radiosynovectomy
Yousefnia, Hassan; Jalilian, Amir Reza; Zolghadri, Samaneh
2014-01-01
Lu-177 of 2.6-3 GBq/mg specific activity was obtained by irradiation of natural Lu2O3 sample with thermal neutron flux of 4 × 1013 n/cm/s. The product was converted into chloride form which was further used for labeling of Lu-177 phytate complex successfully with high radiochemical purity (>99.9%, instant thin layer chromatography, MeOH: H2O: Acetic acid, 4:4:2, as mobile phase). The complex stability and viscosity were checked in the final solution up to 7 days. The prepared complex solution (100 μCi/100 μl) was injected intra-articularly to the male rat knee joint. Leakage of radioactivity from the injection site and its distribution in organs were investigated up to 7 days. Approximately, all injected dose has remained in injection site 7 days after injection. The complex was proved to be a feasible agent for cavital radiotherapy in oncology and rheumatology. PMID:25191108
Incompatibility of Contrast Medium and Trisodium Citrate
DOE Office of Scientific and Technical Information (OSTI.GOV)
Delcour, Christian, E-mail: christian.delcour@chu-charleroi.be; Bruninx, Guy
2013-02-15
To test the compatibility of trisodium citrate, a catheter lock solution, with iodinated contrast medium. Iohexol, iobitridol, iodixanol, ioxaglate, ioxithalamate, iomeprol, and iopromide were tested. In all tests, 2 ml of contrast medium were mixed with 2 ml of trisodium citrate solution. Iodixanol and ioxaglate provoked a highly viscous gluelike precipitation when mixed with trisodium citrate. A brief transient precipitate was observed with iohexol, iomeprol, and ioxithalamate. Permanent precipitation occurred with iobitridol and iopromide. One must be aware of the potential for precipitation when contrast medium is mixed with trisodium citrate solution. Before trisodium citrate solution is injected, the cathetermore » should be thoroughly flushed with saline if a contrast medium has previously been injected through it.« less
Vacuum-integrated electrospray deposition for highly reliable polymer thin film.
Park, Soohyung; Lee, Younjoo; Yi, Yeonjin
2012-10-01
Vacuum electrospray deposition (ESD) equipment was designed to prepare polymer thin films. The polymer solution can be injected directly into vacuum system through multi-stage pumping line, so that the solvent residues and ambient contaminants are highly reduced. To test the performance of ESD system, we fabricated organic photovoltaic cells (OPVCs) by injecting polymer solution directly onto the substrate inside a high vacuum chamber. The OPVC fabricated has the structure of Al∕P3HT:PCBM∕PEDOT:PSS∕ITO and was optimized by varying the speed of solution injection and concentration of the solution. The power conversion efficiency (PCE) of the optimized OPVC is 3.14% under AM 1.5G irradiation without any buffer layer at the cathode side. To test the advantages of the vacuum ESD, we exposed the device to atmosphere between the deposition steps of the active layer and cathode. This showed that the PCE of the vacuum processed device is 24% higher than that of the air exposed device and confirms the advantages of the vacuum prepared polymer film for high performance devices.
NASA Astrophysics Data System (ADS)
Yang, Shaw-Yang; Yeh, Hund-Der; Li, Kuang-Yi
2010-10-01
Heat storage systems are usually used to store waste heat and solar energy. In this study, a mathematical model is developed to predict both the steady-state and transient temperature distributions of an aquifer thermal energy storage (ATES) system after hot water is injected through a well into a confined aquifer. The ATES has a confined aquifer bounded by aquicludes with different thermomechanical properties and geothermal gradients along the depth. Consider that the heat is transferred by conduction and forced convection within the aquifer and by conduction within the aquicludes. The dimensionless semi-analytical solutions of temperature distributions of the ATES system are developed using Laplace and Fourier transforms and their corresponding time-domain results are evaluated numerically by the modified Crump method. The steady-state solution is obtained from the transient solution through the final-value theorem. The effect of the heat transfer coefficient on aquiclude temperature distribution is appreciable only near the outer boundaries of the aquicludes. The present solutions are useful for estimating the temperature distribution of heat injection and the aquifer thermal capacity of ATES systems.
Simulating the injection of micellar solutions to recover diesel in a sand column.
Bernardez, Letícia A; Therrien, René; Lefebvre, René; Martel, Richard
2009-01-26
This paper presents numerical simulations of laboratory experiments where diesel, initially present at 18% residual saturation in a sand column, was recovered by injecting a micellar solution containing the surfactant Hostapur SAS-60 (SAS), and two alcohols, n-butanol (n-BuOH), and n-pentanol (n-PeOH). The micellar solution was developed and optimized for diesel recovery using phase diagrams and soil column experiments. Numerical simulations with the compositional simulator UTCHEM agree with the experimental results and show that the entire residual diesel in the sand column was recovered after the downward injection of 5 pore volumes of the micellar solution. Recovery of diesel occurs by enhanced solubility in the microemulsion phase and by mobilization. An additional series of simulations investigated the effects of phase transfer, alcohol partitioning, and component segregation on diesel recovery. These simulations indicate that diesel can be accurately represented in the model by a single component, but that the pseudo-component approach for active matter and the assumption of local phase equilibrium leads to an underestimation of diesel mobilization.
Simulating the injection of micellar solutions to recover diesel in a sand column
NASA Astrophysics Data System (ADS)
Bernardez, Letícia A.; Therrien, René; Lefebvre, René; Martel, Richard
2009-01-01
This paper presents numerical simulations of laboratory experiments where diesel, initially present at 18% residual saturation in a sand column, was recovered by injecting a micellar solution containing the surfactant Hostapur SAS-60 (SAS), and two alcohols, n-butanol ( n-BuOH), and n-pentanol ( n-PeOH). The micellar solution was developed and optimized for diesel recovery using phase diagrams and soil column experiments. Numerical simulations with the compositional simulator UTCHEM agree with the experimental results and show that the entire residual diesel in the sand column was recovered after the downward injection of 5 pore volumes of the micellar solution. Recovery of diesel occurs by enhanced solubility in the microemulsion phase and by mobilization. An additional series of simulations investigated the effects of phase transfer, alcohol partitioning, and component segregation on diesel recovery. These simulations indicate that diesel can be accurately represented in the model by a single component, but that the pseudo-component approach for active matter and the assumption of local phase equilibrium leads to an underestimation of diesel mobilization.
Earth-moon system: Dynamics and parameter estimation
NASA Technical Reports Server (NTRS)
Breedlove, W. J., Jr.
1975-01-01
A theoretical development of the equations of motion governing the earth-moon system is presented. The earth and moon were treated as finite rigid bodies and a mutual potential was utilized. The sun and remaining planets were treated as particles. Relativistic, non-rigid, and dissipative effects were not included. The translational and rotational motion of the earth and moon were derived in a fully coupled set of equations. Euler parameters were used to model the rotational motions. The mathematical model is intended for use with data analysis software to estimate physical parameters of the earth-moon system using primarily LURE type data. Two program listings are included. Program ANEAMO computes the translational/rotational motion of the earth and moon from analytical solutions. Program RIGEM numerically integrates the fully coupled motions as described above.
NASA Astrophysics Data System (ADS)
Ramadhoni, Benni; Ujianto, Onny; Nadapdap, Maxwell
2018-03-01
Rigid polyurethane (PU) nanocomposites were fabricated via solution mixing of PU, nanoclay and multiwalled carbon nanotubes (MWCNT) according to full factorial DoE. The nanoclay and MWCNT concentration as well as mixing speed were varied. The effects of controlled variables on reduced compressive strength, fire retardancy, hardness and morphological properties were analized. In general, the results showed that incorporation of nanofillers into PU matrix successfully elevated nanocomposites performance. The properties changed from -12% to 45% for reduced compressive strength, 9% to 30% for reduced fire retardancy and -32% to 101% for reduced hardness. The results suggested that the improvements were affected by nanoclay dispersion that acted as nucleating agent which resulted in smaller close cells of PU structures.
Stress intensity factors in a cracked infinite elastic wedge loaded by a rigid punch
NASA Technical Reports Server (NTRS)
Erdogan, F.; Civelek, M. B.
1978-01-01
A plane elastic wedge-shaped solid was split through the application of a rigid punch. It was assumed that the coefficient of friction on the the contact area was constant, and the problem had a plane of symmetry with respect to loading and geometry, with the crack in the plane of symmetry. The problem was formulated in terms of a system of integral equations with the contact stress and the derivative of the crack surface displacement as the unknown functions. The solution was obtained for an internal crack and for an edge crack. The results include primarily the stress intensity factors at the crack tips, and the measure of the stress singularity at the wedge apex, and at the end points of the contact area.
Film thickness for different regimes of fluid-film lubrication. [elliptical contacts
NASA Technical Reports Server (NTRS)
Hamrock, B. J.; Dowson, D.
1983-01-01
Mathematical formulas are presented which express the dimensionless minimum film thickness for the four lubrication regimes found in elliptical contacts: isoviscous-rigid regime; piezoviscous-rigid regime; isoviscous-elastic regime; and piezoviscous-elastic regime. The relative importance of pressure on elastic distortion and lubricant viscosity is the factor that distinguishes these regimes for a given conjunction geometry. In addition, these equations were used to develop maps of the lubrication regimes by plotting film thickness contours on a log-log grid of the dimensionless viscosity and elasticity parameters for three values of the ellipticity parameter. These results present a complete theoretical film thickness parameter solution for elliptical constants in the four lubrication regimes. The results are particularly useful in initial investigations of many practical lubrication problems involving elliptical conjunctions.
Geometry and design of origami bellows with tunable response
NASA Astrophysics Data System (ADS)
Reid, Austin; Lechenault, Frederic; Rica, Sergio; Adda-Bedia, Mokhtar
2017-01-01
Origami folded cylinders (origami bellows) have found increasingly sophisticated applications in space flight and medicine. In spite of this interest, a general understanding of the mechanics of an origami folded cylinder has been elusive. With a newly developed set of geometrical tools, we have found an analytic solution for all possible cylindrical rigid-face states of both Miura-ori and triangular tessellations. Although an idealized bellows in both of these families may have two allowed rigid-face configurations over a well-defined region, the corresponding physical device, limited by nonzero material thickness and forced to balance hinge and plate-bending energy, often cannot stably maintain a stowed configuration. We have identified the parameters that control this emergent bistability, and we have demonstrated the ability to design and fabricate bellows with tunable deployability.
Geometry and design of origami bellows with tunable response.
Reid, Austin; Lechenault, Frederic; Rica, Sergio; Adda-Bedia, Mokhtar
2017-01-01
Origami folded cylinders (origami bellows) have found increasingly sophisticated applications in space flight and medicine. In spite of this interest, a general understanding of the mechanics of an origami folded cylinder has been elusive. With a newly developed set of geometrical tools, we have found an analytic solution for all possible cylindrical rigid-face states of both Miura-ori and triangular tessellations. Although an idealized bellows in both of these families may have two allowed rigid-face configurations over a well-defined region, the corresponding physical device, limited by nonzero material thickness and forced to balance hinge and plate-bending energy, often cannot stably maintain a stowed configuration. We have identified the parameters that control this emergent bistability, and we have demonstrated the ability to design and fabricate bellows with tunable deployability.
[Analysis of inadvertent epidural injection of drugs].
Kasaba, T; Uehara, K; Katsuki, H; Ono, Y; Takasaki, M
2000-12-01
We asked 31 anesthesiologists, who were on the Japanese Board of Anesthesiology, about inadvertent injection of drugs into the epidural space, and received answers from 28 (90%). Fifteen (54%) had an experience of inadvertent epidural injection, and five of them had two experiences. Injected drugs were ephedrine (6 times), a mixture of neostigmine and atropine (3), thiopental (2), etilefrine (2), vecuronium (1), suxamethonium (1), bicarbonate (1), midazolam (1), lactated Ringer's solution (1), nicardipine (1), and pentazocine (1). The inadvertent injection of thiopental or bicarbonate was noticed by back pain during injection. No treatment was added after the inadvertent injections, except a patient with an epidural steroid injection following thiopental. No neurological complications were found in any patients.
Moran, Kenneth A
2016-06-04
Recent changes in the United States (US) economy have radically disrupted revenue generation among many institutions within higher education within the US. Chief among these disruptions has been fallout associated with the financial crisis of 2008-2009, which triggered a change in the US higher education environment from a period of relative munificence to a prolonged period of scarcity. The hardest hit by this disruption have been smaller, less wealthy institutions which tend to lack the necessary reserves to financially weather the economic storm. Interestingly, a review of institutional effectiveness among these institutions revealed that while many are struggling, some institutions have found ways to not only successfully cope with the impact of declining revenue, but have been able to capitalize on the disruption and thrive. Organizational response is an important factor in successfully coping with conditions of organizational decline. The study examined the impacts of organizational response on institutional effectiveness among higher education institutions experiencing organizational decline. The study's research question asked why some US higher educational institutions are more resilient at coping with organizational decline than other institutions operating within the same segment of the higher education sector. More specifically, what role does organizational resilience have in helping smaller, private non-profit institutions cope and remain effective during organizational decline? A total of 141 US smaller, private non-profit higher educational institutions participated in the study; specifically, the study included responses from participant institutions' key administrators. 60-item survey evaluated administrator responses corresponding to organizational response and institutional effectiveness. Factor analysis was used to specify the underlying structures of rigidity response, resilience response, and institutional effectiveness. Multiple regression analysis was used to examine the direct and interaction effects between organizational decline, organizational rigidity response, organizational resilience response, and institutional effectiveness, controlling for age of institution and level of endowment. The study validated previous threat-rigidity response findings that organizational decline alone does not adversely impact institutional effectiveness. The direct effect of Goal-Directed Solution Seeking and Role Dependency organizational resilience factors had a positive, significant correlation with the Student Personal Development institutional effectiveness factor. The interactive effect of Goal-Directed Solution Seeking organizational resilience factor during organizational decline had a positive, significant correlation with the Professional Development and Quality of Faculty institutional effectiveness factor. The interactive effect of Avoidance during organizational decline had a positive, significant correlation with the Faculty and Administrator Employment Satisfaction institutional effectiveness factor. The interactive effect of Diminished Innovation, Morale, and Leader Credibility rigidity response factor and Avoidance organizational resilience factor during organizational decline had a positive, significant correlation with the Professional Development and Quality of Faculty institutional effectiveness factor. Lastly, the interactive effect of Increased Scapegoating of Leaders, Interest group Activities, and Conflict rigidity response factor and Avoidance organizational resilience factor during organizational decline had a positive, significant correlation with the Faculty and Administrator Employment Satisfaction institutional effectiveness factor. Factors of organizational resilience were found to have a positive effect among smaller, private non-profit higher educational institutions associated with this study toward sustaining institutional effectiveness during organizational decline. Specifically, the organizational resilience factors of Goal-Directed Solution Seeking (i.e., mission-driven solutions) and Avoidance (i.e., skepticism toward new ideas) play a significant, collaborative role among smaller, private non-profit higher educational institutions when it comes to sustaining institutional effectiveness during organizational decline.
Use of Tricaine Methanesulfonate (MS222) for Euthanasia of Reptiles
Conroy, CJ; Papenfuss, T; Parker, J; Hahn, NE
2009-01-01
Tricaine methanesulfonate (MS222) injected into the intracoelomic cavity of reptiles was evaluated as a chemical euthanasia method. Three western fence lizards, 2 desert iguanas, 4 garter snakes, and 6 geckos were euthanized by intracoelomic injection of 250 to 500 mg/kg of 0.7% to 1% sodium-bicarbonate–buffered MS222 solution followed by intracoelomic injection of 0.1 to 1.0 ml unbuffered 50% (v/v) MS222 solution. A simple 2-stage protocol for euthanasia of reptiles by using MS222 is outlined. In addition, the conditions for safe use of MS222 are discussed. MS222 offers an alternative to sodium pentobarbital for euthanasia of reptiles. PMID:19245747
NASA Astrophysics Data System (ADS)
Roch, A.; Huber, T.; Henning, F.; Elsner, P.
2014-05-01
Investigations on PP-LGF30 foam sandwiches have been carried out using different manufacturing processes: standard injection molding, MuCell® and LFT-D foam. Both chemical and physical blowing agents were applied. Precision mold opening (breathing mold technology) was selected for the foaming process. The integral foam design, which can be conceived as a sandwich structure, helps to save material in the neutral axis area and maintains a distance between load-bearing, unfoamed skin layers. The experiments showed that, at a constant mass per unit area, integral foams have a significantly higher flexural rigidity than compact components, due to their greater area moment of inertia after foaming: with an increase of the wall thickness from 3.6 mm to 4.4 mm compared to compact construction, the flexural rigidity increased by 75 %. With a final wall thickness of 5.8 mm an increase of 300 % was measured. Compared to non-reinforced components that show significant embrittlement during foaming, the energy absorption capacity (impact strength) of LFT foam components remains almost constant.
21 CFR 522.1680 - Oxytocin injection.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Oxytocin injection. 522.1680 Section 522.1680 Food... Oxytocin injection. (a) Specifications. Each milliliter (mL) of solution contains 20 USP units oxytocin. (b... 10 to 20. Sows 0.25 to 1.0 5 to 20. (2) Indications for use. Oxytocin may be used as a uterine...
Local Anesthetic Microencapsulation.
1983-11-04
tollowing I.M. injection of microencapsulated lidocaine and etidocaine than following solution injections. Local toxicity of these microcapsule injections...Distribution 41 Table 12 Processing Summary of Lidocaine (Base) 43 Microencapsulation Table 13 Lidocaine (Base) Microcapsule Size 44 Distribution...Table 14 Processing Summary of Et’idocaine-HCl 45 Microencapsulation Table 15 Etidocaine-HCl Microcapsule Size 47 Distribution Table 16 Process Summary
NASA Astrophysics Data System (ADS)
Shan, Yanguang; Coyle, Thomas W.; Mostaghimi, Javad
2007-12-01
Solution precursor plasma spraying has been used to produce finely structured ceramic coatings with nano- and sub-micrometric features. This process involves the injection of a solution spray of ceramic salts into a DC plasma jet under atmospheric condition. During the process, the solvent vaporizes as the droplet travel downstream. Solid particles are finally formed due to the precipitation of the solute, and the particle are heated up and accelerated to the substrate to generate the coating. This article describes a 3D model to simulate the transport phenomena and the trajectory and heating of the solution spray in the process. The jet-spray two-way interactions are considered. A simplified model is employed to simulate the evolution process and the formation of the solid particle from the solution droplet in the plasma jet. The temperature and velocity fields of the jet are obtained and validated. The particle size, velocity, temperature, and position distribution on the substrate are predicted.
Burst nucleation by hot injection for size controlled synthesis of ε-cobalt nanoparticles.
Zacharaki, Eirini; Kalyva, Maria; Fjellvåg, Helmer; Sjåstad, Anja Olafsen
2016-01-01
Reproducible growth of narrow size distributed ε-Co nanoparticles with a specific size requires full understanding and identification of the role of essential synthesis parameters for the applied synthesis method. For the hot injection methodology, a significant discrepancy with respect to obtained sizes and applied reaction conditions is reported. Currently, a systematic investigation controlling key synthesis parameters as injection-temperature and time, metal to surfactant ratio and reaction holding time in terms of their impact on mean ([Formula: see text]mean) and median ([Formula: see text]median) particle diameter using dichlorobenzene (DCB), Co2(CO)8 and oleic acid (OA) as the reactant matrix is lacking. A series of solution-based ε-Co nanoparticles were synthesized using the hot injection method. Suspensions and obtained particles were analyzed by DLS, ICP-OES, (synchrotron)XRD and TEM. Rietveld refinements were used for structural analysis. Mean ([Formula: see text]mean) and median ([Formula: see text]median) particle diameters were calculated with basis in measurements of 250-500 particles for each synthesis. 95 % bias corrected confidence intervals using bootstrapping were calculated for syntheses with three or four replicas. ε-Co NPs in the size range ~4-10 nm with a narrow size distribution are obtained via the hot injection method, using OA as the sole surfactant. Typically the synthesis yield is ~75 %, and the particles form stable colloidal solutions when redispersed in hexane. Reproducibility of the adopted synthesis procedure on replicate syntheses was confirmed. We describe in detail the effects of essential synthesis parameters, such as injection-temperature and time, metal to surfactant ratio and reaction holding time in terms of their impact on mean ([Formula: see text]mean) and median ([Formula: see text]median) particle diameter. The described synthesis procedure towards ε-Co nanoparticles (NPs) is concluded to be robust when controlling key synthesis parameters, giving targeted particle diameters with a narrow size distribution. We have identified two major synthesis parameters which control particle size, i.e., the metal to surfactant molar ratio and the injection temperature of the hot OA-DCB solution into which the cobalt precursor is injected. By increasing the metal to surfactant molar ratio, the mean particle diameter of the ε-Co NPs has been found to increase. Furthermore, an increase in the injection temperature of the hot OA-DCB solution into which the cobalt precursor is injected, results in a decrease in the mean particle diameter of the ε-Co NPs, when the metal to surfactant molar ratio [Formula: see text] is fixed at ~12.9.
Physical and chemical stability of palonosetron HCl in 4 infusion solutions.
Trissel, Lawrence A; Xu, Quanyun A
2004-10-01
Palonosetron HCl is a selective 5-HT(3) receptor antagonist used for the prevention of chemotherapy-induced nausea and vomiting. Palonosetron HCl may be diluted in an infusion solution for administraton. Consequently, stability information is needed for palonosetron HCl admixed in common infusion solutions. To evaluate the physical and chemical stability of palonosetron HCl in concentrations of 5 and 30 microg/mL in dextrose 5% injection, NaCl 0.9% injection, dextrose 5% in NaCl 0.45% injection, and dextrose 5% in lactated Ringer's injection. Triplicate test samples of palonosetron HCl at each concentration in each diluent were tested. Samples were stored and evaluated at appropriate intervals for up to 48 hours at room temperature ( approximately 23 degrees C) and 14 days under refrigeration (4 degrees C). Physical stability was assessed using turbidimetric and particulate measurement, as well as visual inspection. Chemical stability was assessed by HPLC. All of the admixtures were initially clear and colorless when viewed in normal fluorescent room light and with a Tyndall beam. Measured turbidity and particulate content were low initially and remained low throughout the study. The drug concentration was unchanged in any of the samples at either temperature throughout the study. Palonosetron HCl is physically and chemically stable in all 4 common infusion solutions for at least 48 hours at room temperature and 14 days under refrigeration.
Beck, William; Kabiche, Sofiane; Balde, Issa-Bella; Carret, Sandra; Fontan, Jean-Eudes; Cisternino, Salvatore; Schlatter, Joël
2016-12-01
To assess the stability of pharmaceutical suxamethonium (succinylcholine) solution for injection by validated stability-indicating chromatographic method in vials stored at room temperature. The chromatographic assay was achieved by using a detector wavelength set at 218 nm, a C18 column, and an isocratic mobile phase (100% of water) at a flow rate of 0.6 mL/min for 5 minutes. The method was validated according to the International Conference on Harmonization guidelines with respect to the stability-indicating capacity of the method including linearity, limits of detection and quantitation, precision, accuracy, system suitability, robustness, and forced degradations. Linearity was achieved in the concentration range of 5 to 40 mg/mL with a correlation coefficient higher than 0.999. The limits of detection and quantification were 0.8 and 0.9 mg/mL, respectively. The percentage relative standard deviation for intraday (1.3-1.7) and interday (0.1-2.0) precision was found to be less than 2.1%. Accuracy was assessed by the recovery test of suxamethonium from solution for injection (99.5%-101.2%). Storage of suxamethonium solution for injection vials at ambient temperature (22°C-26°C) for 17 days demonstrated that at least 95% of original suxamethonium concentration remained stable. Copyright © 2016 Elsevier Inc. All rights reserved.
Yokoyama, H; Aoyama, T; Matsuyama, T; Yamamura, Y; Nakajima, K; Nakamura, K; Sato, H; Kotaki, H; Chiba, S; Hirai, H; Yazaki, Y; Iga, T
1998-12-01
We studied the cause of cracking of a clinically used polyurethane (PU) catheter during the constant infusion of etoposide (VP-16) injection (Lastet), administered without dilution to patients as a part of combination high-dose chemotherapy. After VP-16 injection was infused into the PU catheter at a constant infusion rate (30 ml/h) for 24 h, a decrease in the elasticity (36% of untreated) and on increase in the length of the catheter (3.7%) were observed. These changes were significantly higher than those treated with the control saline. The similar changes of the PU catheter were observed after treatment with a basal solution containing polyethylene glycol 400 (PEG 400), polysorbate 80 and ethanol, which is the vehicle of the VP-16 injection, and with ethanol alone. Moreover, obvious degeneration of the internal wall (occurrence of spots like melting) and cutting face (micro-cracking) of the catheter was observed with an electron microscope after treatment with the vehicle. On the other hand, the elasticity or extension of the PU catheter were not changed after treatment with saline or PEG 400. From these findings, it was suggested that the degeneration and subsequent cracking of the PU catheter during the infusion of VP-16 injection was caused by ethanol contained in its injection solution. No cracking or morphological changes of polyvinyl chloride (PVC) and silicone catheters were found after treatment with the vehicle solution. However, since it has been reported in previous reports that di(2-ethylhexyl)phthalate was leached from PVC bags, the high dose chemotherapy with the dilution-free VP-16 injection should be achieved safely and effectively using a silicon catheter, rather than the PU catheter.
An ultramicroscopic study on rigor mortis.
Suzuki, T
1976-01-01
Gastrocnemius muscles taken from decapitated mice at various intervals after death and from mice killed by 2,4-dinitrophenol or mono-iodoacetic acid injection to induce rigor mortis soon after death, were observed by electron microscopy. The prominent appearance of many fine cross striations in the myofibrils (occurring about every 400 A) was considered to be characteristic of rigor mortis. These striations were caused by minute granules studded along the surfaces of both thick and thin filaments and appeared to be the bridges connecting the 2 kinds of filaments and accounted for the hardness and rigidity of the muscle.
Mehnert, Ulrich; Boy, Sönke; Schmid, Marius; Reitz, André; von Hessling, Alexander; Hodler, Juerg; Schurch, Brigitte
2009-06-01
Although botulinum neurotoxin type A (BoNT/A) intradetrusor injections are a recommended therapy for neurogenic detrusor overactivity (NDO), refractory to antimuscarinic drugs, a standardisation of injection technique is missing. Furthermore, some basic questions are still unanswered, as where the toxin solution exactly spreads after injection. Therefore, we investigated the distribution of the toxin solution after injection into the bladder wall, using magnet resonance imaging (MRI). Six patients with NDO were recruited. Three of six patients received 300 U of BoNT/A + contrast agent distributed over 30 injection sites (group 1). The other three patients received 300 U of BoNT/A + contrast agent distributed over 10 injection sites (group 2). Immediately after injection, MRI of the pelvis was performed. The volume of the detrusor and the total volume of contrast medium inside and outside the bladder wall were calculated. In all patients, a small volume (mean 17.6%) was found at the lateral aspects of the bladder dome in the extraperitoneal fat tissue, whereas 82.4% of the injected volume reached the target area (detrusor). In both groups there was a similar distribution of the contrast medium in the target area. A mean of 33.3 and 25.3% of the total detrusor volume was covered in group 1 and 2, respectively. Six weeks after injection, five of six patients were continent and showed no detrusor overactivity in the urodynamic follow-up. No systemic side effects were observed. Our results provide morphological arguments that the currently used injection techniques are appropriate and safe.
Physical characterization and modeling of chitosan/peg blends for injectable scaffolds.
Lima, Daniel B; Almeida, Renata D; Pasquali, Matheus; Borges, Sílvia P; Fook, Marcus L; Lisboa, Hugo M
2018-06-01
Injectable scaffolds find many applications on the biomedical field due to several advantages on preformed scaffolds such as being able to fill any defect can be used in minimal invasion surgeries and are ready to use products. The most critical parameter for an injectable scaffold usage is its injectability, which can be related with rheological properties. Therefore, the objective of the present work was to increase knowledge about the critical parameters influencing injectability of biopolymers used for injectable scaffolds. Rheological and mechanical properties of a biopolymer blend in combination with injectability tests for a given design space controlled by the concentrations of both polymers and temperatures was made. Then those results were modeled to better understand the impact of parameters on injectability. The biopolymer blend chosen was Chitosan physically blended with Poly(ethylene glycol) where variations of both polymer concentrations and molecular weights were tested. Rheological and mechanical properties of all samples were determined, together with the injection force using a compression test at different injection conditions. All solutions were clear and transparent suggesting perfect miscibility. Rheological results were modeled using Ostwald-Waelle law and revealed a shear thinning pseudo-plastic solution at any composition and temperature, being chitosan concentration the most influencing variable. Compression tests results revealed mean injection forces ranging from 9.9 ± 0.06N to 29.9 ± 0.65N and it was possible to accurately estimate those results. Simulations revealed draw speed as the most influencing parameter. Cell viability tests revealed a non-cytotoxic biopolymer blend. Copyright © 2018 Elsevier Ltd. All rights reserved.
Castelli, Andrea; Meinardi, Francesco; Pasini, Mariacecilia; Galeotti, Francesco; Pinchetti, Valerio; Lorenzon, Monica; Manna, Liberato; Moreels, Iwan; Giovanella, Umberto; Brovelli, Sergio
2015-08-12
Colloidal quantum dots (QDs) are emerging as true candidates for light-emitting diodes with ultrasaturated colors. Here, we combine CdSe/CdS dot-in-rod heterostructures and polar/polyelectrolytic conjugated polymers to demonstrate the first example of fully solution-based quantum dot light-emitting diodes (QD-LEDs) incorporating all-organic injection/transport layers with high brightness, very limited roll-off and external quantum efficiency as high as 6.1%, which is 20 times higher than the record QD-LEDs with all-solution-processed organic interlayers and exceeds by over 200% QD-LEDs embedding vacuum-deposited organic molecules.
Integration of the Rotation of an Earth-like Body as a Perturbed Spherical Rotor
NASA Astrophysics Data System (ADS)
Ferrer, Sebastián; Lara, Martin
2010-05-01
For rigid bodies close to a sphere, we propose an analytical solution that is free from elliptic integrals and functions, and can be fundamental for application to perturbed problems. After reordering the Hamiltonian as a perturbed spherical rotor, the Lie-series solution is generated up to an arbitrary order. Using the inertia parameters of different solar system bodies, the comparison of the approximate series solution with the exact analytical one shows that the precision reached with relatively low orders is at the same level of the observational accuracy for the Earth and Mars. Thus, for instance, the periodic errors of the mathematical solution are confined to the microarcsecond level with a simple second-order truncation for the Earth. On the contrary, higher orders are required for the mathematical solution to reach a precision at the expected level of accuracy of proposed new theories for the rotational dynamics of the Moon.
Enhanced immunity in intradermal vaccination by novel hollow microneedles.
Ogai, N; Nonaka, I; Toda, Y; Ono, T; Minegishi, S; Inou, A; Hachiya, M; Fukamizu, H
2018-04-29
The intradermal (ID) route for vaccination represents an effective alternative to subcutaneous (SC)/intramuscular administration to induce protective immunity. However, a critical issue associated with ID vaccination is the precise delivery of solution in the upper dermis, which ensures enhanced immunity. We fabricated a hollow microneedle unit made of poly-glycolic acid by injection molding and bonding, and created a dedicated prototype injector. To ensure ID delivery of solution, the injected site was macroscopically and microscopically examined. Serum immunoglobulin G antibody production was measured by enzyme immunoassay and compared in groups of rats following either ID delivery with microneedles or SC administration with a 27-G stainless needle of graded vaccine doses. The unit used a tandem array of six microneedles, each with a side delivery hole, and a conduit inside for solution. Microneedles installed in the injector punctured the skin with the aid of a spring. Injection of solution formed a wheal due to ID distribution. Histologically, a wedge-shaped skin defect in the upper skin corresponded to each puncture site. Antibody titers following vaccinations on days 1 and 8 were significantly higher with ID injection than with SC delivery on day 15 and every 7 days thereafter until day 36 with mumps vaccination, and until day 36 with varicella vaccination. The microneedle unit presented here delivered solution intradermally without any difficulty and evoked antibody responses against viruses even with the reduced vaccine volume. Our findings confirm promising results of ID delivery as an immunogenic option to enhance vaccination efficacy. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
A pilot study of the validation of percutaneous testing in cats.
Rossi, Michael A; Messinger, Linda; Olivry, Thierry; Hoontrakoon, Raweewan
2013-10-01
Intradermal testing is useful for the identification of environmental allergens to which cats could be hypersensitive; intradermal test reactions are often subtle and difficult to interpret in cats. Percutaneous testing is the standard technique for the detection of significant environmental allergens in people, but it has not yet been evaluated in cats with hypersensitivity dermatitis. The purpose of this study was to evaluate and compare the skin test responses of healthy cats to percutaneous application and intradermal injections of control solutions. Ten clinically healthy cats were studied. Percutaneous applications of 0.0275 and 0.1 mg/mL aqueous histamine, 6 mg/mL glycerinated histamine, 0.9% buffered saline and 50% glycerosaline solution were performed using Greer Pick (Greer Laboratories, Lenoir, NC, USA) and Duotip-Test II (Lincoln Diagnostics, Decatur, IL, USA) percutaneous applicators. Reactions were compared with intradermal injections of 0.0275 mg/mL aqueous histamine and 0.9% buffered saline as controls. Positive responses to histamine solutions were significantly greater with the Greer Pick than with the Duotip-Test II. There were no significant differences between the histamine reactions using the Greer Pick applicator and the intradermal injections. Percutaneous reactions to histamine were more well demarcated and easier to read than intradermal injection reactions. Reactions to the saline controls were not noted. Percutaneous application of 6 mg/mL glycerinated histamine solution, 50% glycerosaline solution and 0.9% buffered saline produced similar positive and negative control wheals. These observations warrant further studies of percutaneous allergen testing in cats with hypersensitivity dermatitis. © 2013 ESVD and ACVD.
NASA Technical Reports Server (NTRS)
Ellison, Donald C.; Moebius, Eberhard; Paschmann, Goetz
1990-01-01
The injection and acceleration of thermal solar wind ions at the quasi-parallel earth's bow shock during radial interplanetary magnetic field conditions is investigated. Active Magnetospheric Particle Tracer Explorers/Ion Release Module satellite observations of complete proton spectra, and of heavy ion spectra above 10 keV/Q, made on September 12, 1984 near the nose of the shock, are presented and compared to the predictions of a Monte Carlo shock simulation which includes diffusive shock acceleration. It is found that the spectral observations are in good agreement with the predictions of the simulation when it is assumed that all accelerated ions originate in the solar wind and are injected into the acceleration mechanism by thermal leakage from the downstream plasma. The efficiency, which is determined directly from the downstream observations, is high, with at least 15 percent of the solar wind energy flux going into accelerated particles. The comparisons allow constraints to be placed on the rigidity dependence of the scattering mean free path and suggest that the upstream solar wind must be slowed substantially by backstreaming accelerated ions prior to undergoing a sharp transition in the viscous subshock.
The dynamics of domain walls and strings
NASA Technical Reports Server (NTRS)
Gregory, Ruth; Haws, David; Garfinkle, David
1989-01-01
The leading order finite-width corrections to the equation of motion describing the motion of a domain wall are derived. The regime in which this equation of motion is invalid is discussed. Spherically and cylindrically symmetric solutions to this equation of motion are found. A misconception that has arisen in recent years regarding the rigidity (or otherwise) of cosmic strings is also clarified.
2012-03-01
properties of such resins are poor. Various solutions have been proposed over the years, but most suffer from a number of drawbacks that have...as a pendulum into a rigid wall. The flatwise drop involved dropping the container flatwise onto the feet from 15 and 30 cm. The stacking test
Attic Retrofits Using Nail-Base Insulated Panels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mallay, David; Kochkin, Vladimir
This project developed and demonstrated a roof/attic energy retrofit solution using nail-base insulated panels for existing homes where traditional attic insulation approaches are not effective or feasible. Nail-base insulated panels (retrofit panels) consist of rigid foam insulation laminated to one face of a wood structural panel. The prefabricated panels are installed above the existing roof deck during a reroofing effort.
ERIC Educational Resources Information Center
MacFarland, Thomas W.; Yates, Jan M.
Gaining access to current and high-quality curriculum resource materials has become more difficult due to escalation in the prices of textbooks and in rigid interpretations of copyright laws which limit photocopying. Internet Frequently Asked Questions (FAQs) and files may offer a partial solution. Originally developed for the benefit of Usenet…
ERIC Educational Resources Information Center
Isokawa, Naho; Fueda, Kazuki; Miyagawa, Korin; Kanno, Kenichi
2015-01-01
Poly(vinyl alcohol) (PVA) precipitates in many kinds of aqueous salt solutions. While sodium sulfate, a coagulant for PVA fiber, precipitates PVA to yield a white rigid gel, coagulation of PVA with aluminum sulfate, a coagulant for water treatment, yields a slime-like viscoelastic fluid. One type of homemade slime is prepared under basic…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, I.Y.; Tirziu, A.; Tseytlin, A.A.
We consider circular strings rotating with equal spins S{sub 1}=S{sub 2}=S in two orthogonal planes in AdS{sub 5} and suggest that they may be dual to long gauge-theory operators built out of self-dual components of gauge field strength. As was found in hep-th/0404187, the one-loop anomalous dimensions of the such gauge-theory operators are described by an antiferromagnetic XXX{sub 1} spin chain and scale linearly with length L>>1. We find that in the case of rigid rotating string both the classical energy E{sub 0} and the 1-loop string correction E{sub 1} depend linearly on the spin S (within the stability regionmore » of the solution). This supports the identification of the rigid rotating string with the gauge-theory operator corresponding to the maximal-spin (ferromagnetic) state of the XXX{sub 1} spin chain. The energy of more general rotating and pulsating strings also happens to scale linearly with both the spin and the oscillation number. Such solutions should be dual to other lower-spin states of the spin chain, with the antiferromagnetic ground state presumably corresponding to the string pulsating in two planes with no rotation.« less
Alternating current electroosmotic flow in polyelectrolyte-grafted nanochannel.
Li, Fengqin; Jian, Yongjun; Chang, Long; Zhao, Guangpu; Yang, Liangui
2016-11-01
In this work, we investigate the time periodic electroosmotic flow (EOF) of an electrolyte solution through a slit polyelectrolyte-grafted (PE-grafted) nanochannel under applied alternating current (AC) electrical field. The PE-grafted nanochannel is represented by a rigid surface covered by a polyelectrolyte layer (PEL) in a brush-like configuration. Under Debye-Hückel approximation, we obtain analytical solutions of electrical potential in decoupled regime of PE-grafted nanochannel, where the thickness of PEL is independent of the electrostatic effects triggered by polyelectrolyte charges. Based upon the electrical potential obtained above, we calculate EOF velocities with uniform and non-uniform drag coefficients for PE-grafted nanochannel and compare their results. The effects of pertinent dimensionless parameters on EOF velocity amplitude are discussed in detail. Moreover, the amplitude of EOF velocity in a PE-grafted nanochannel is compared with that in a rigid one. It is shown that larger EOF velocity and volume flow rate are found for a PE-grafted nanochannel. In addition, AC EOF velocity is further investigated. The oscillation of velocity reduces and is restricted within the region near the PEL-electrolyte interface for higher oscillating Reynolds number Re. Copyright © 2016 Elsevier B.V. All rights reserved.
Arutiunian, A V; Ivanova, M A; Kurliand, D I; Kapshin, Iu S; Landa, S B; Poshekhonov, S T; Drobchenko, E A; Shevelev, I V
2011-01-01
Changes in the rigidity of the polymetric chain of phage lambda double-strand DNA have been studied by laser correlation spectroscopy. It was shown that, as the ionic strength increases, the effect of the screening of the hydrodynamic interaction of the links of the polymeric chain specific for polymeric coils arises in a DNA solution. It is assumed that the screening occurs when the threshold of the overlapping of DNA coils is achieved. The overlapping of coils is the result of a previously observed significant rise of DNA coil size from abnormally small DNA coils in low ionic strength buffers (about 10(-2) M Na+ or less) to maximum possible large coils in the 5SSC and 5SSC-like buffers. Further analysis of the far interlink interactions in linear lambda phage DNA coils in similar buffers at pH 7 and 4 confirms the earlier proposal about the role of H+ ions in the appearance of abnormally small DNA coils. The abnormal decrease in the DNA coil size in low ionic strength buffers is not a specific feature of lambda phage DNA only.
Rigid Origami via Optical Programming and Deferred Self-Folding of a Two-Stage Photopolymer.
Glugla, David J; Alim, Marvin D; Byars, Keaton D; Nair, Devatha P; Bowman, Christopher N; Maute, Kurt K; McLeod, Robert R
2016-11-02
We demonstrate the formation of shape-programmed, glassy origami structures using a single-layer photopolymer with two mechanically distinct phases. The latent origami pattern consisting of rigid, high cross-link density panels and flexible, low cross-link density creases is fabricated using a series of photomask exposures. Strong optical absorption of the polymer formulation creates depth-wise gradients in the cross-link density of the creases, enforcing directed folding which enables programming of both mountain and valley folds within the same sheet. These multiple photomask patterns can be sequentially applied because the sheet remains flat until immersed into a photopolymerizable monomer solution that differentially swells the polymer to fold and form the origami structure. After folding, a uniform photoexposure polymerizes the absorbed solution, permanently fixing the shape of the folded structure while simultaneously increasing the modulus of the folds. This approach creates sharp folds by mimicking the stiff panels and flexible creases of paper origami while overcoming the traditional trade-off of self-actuated materials that require low modulus for folding and high modulus for mechanical robustness. Using this process, we demonstrate a waterbomb base capable of supporting 1500 times its own weight.
Sun, Fengyuan; Huang, Qilin; Wu, Jianyong
2014-12-19
The rheological behaviors of an exopolysaccharide (EPS) from a Cordyceps sinensis fungus fermentation were investigated. The intrinsic viscosity of 1986 ± 55 mL/g indicated an extended and rigid chain for EPS. Shear-thinning behavior was observed and became apparent with increasing concentration. According to cross model, two critical transition concentrations (c(*) and c(**)) from dilute solution to semidilute and then to concentrated domain were 0.45 and 6.14 mg/mL. Flow activation energy was calculated by Arrhenius equation and decreased with increasing concentration, indicating a lower sensitivity to temperature. From dynamic frequency sweep, EPS system was classified to three regions including dilution solution (1.25mg/mL), entanglement network (3.75 and 5.00 mg/mL) and weak gel (≥ 7.50 mg/mL). Notably, the increase in η(*) at high frequencies was attributed to a large flow resistance depended on the rigid chain of EPS. Based on Winter-Chambon criterion, EPS formed gel at 2.6 mg/mL (cgel) and showed typical weak gel from temperature ramp and repetitive strain sweep. Copyright © 2014 Elsevier Ltd. All rights reserved.
A Numerical Model of Unsteady, Subsonic Aeroelastic Behavior. Ph.D Thesis
NASA Technical Reports Server (NTRS)
Strganac, Thomas W.
1987-01-01
A method for predicting unsteady, subsonic aeroelastic responses was developed. The technique accounts for aerodynamic nonlinearities associated with angles of attack, vortex-dominated flow, static deformations, and unsteady behavior. The fluid and the wing together are treated as a single dynamical system, and the equations of motion for the structure and flow field are integrated simultaneously and interactively in the time domain. The method employs an iterative scheme based on a predictor-corrector technique. The aerodynamic loads are computed by the general unsteady vortex-lattice method and are determined simultaneously with the motion of the wing. Because the unsteady vortex-lattice method predicts the wake as part of the solution, the history of the motion is taken into account; hysteresis is predicted. Two models are used to demonstrate the technique: a rigid wing on an elastic support experiencing plunge and pitch about the elastic axis, and an elastic wing rigidly supported at the root chord experiencing spanwise bending and twisting. The method can be readily extended to account for structural nonlinearities and/or substitute aerodynamic load models. The time domain solution coupled with the unsteady vortex-lattice method provides the capability of graphically depicting wing and wake motion.
Convective transport resistance in the vitreous humor
NASA Astrophysics Data System (ADS)
Penkova, Anita; Sadhal, Satwindar; Ratanakijsuntorn, Komsan; Moats, Rex; Tang, Yang; Hughes, Patrick; Robinson, Michael; Lee, Susan
2012-11-01
It has been established by MRI visualization experiments that the convection of nanoparticles and large molecules with high rate of water flow in the vitreous humor will experience resistance, depending on the respective permeabilities of the injected solute. A set of experiments conducted with Gd-DTPA (Magnevist, Bayer AG, Leverkusen, Germany) and 30 nm gadolinium-based particles (Gado CELLTrackTM, Biopal, Worcester, MA) as MRI contrast agents showed that the degree of convective transport in this Darcy-type porous medium varies between the two solutes. These experiments consisted of injecting a mixture of the two (a 30 μl solution of 2% Magnevist and 1% nanoparticles) at the middle of the vitreous of an ex vivo whole bovine eye and subjecting the vitreous to water flow rate of 100 μl/min. The water (0.9% saline solution) was injected at the top of the eye, and was allowed to drain through small slits cut at the bottom of the eyeball. After 50 minutes of pumping, MRI images showed that the water flow carried the Gd-DTPA farther than the nanoparticles, even though the two solutes, being mixed, were subjected to the same convective flow conditions. We find that the convected solute lags the water flow, depending on the solute permeability. The usual convection term needs to be adjusted to allow for the filtration effect on the larger particles in the form (1- σ) u . ∇ c with important implications for the modeling of such systems.
Kim, Insu; Lee, Minhee
2012-11-30
A pilot scale test for a process combining in-situ chemical oxidation using H(2)O(2) solution with biodegradation was performed to remove TPH from a diesel contaminated military site. In batch experiments, when 20% H(2)O(2) solution was used for TPH contaminated soil, TPH removal efficiency was 63.5%. Batch experiments investigating biodegradation by adding indigenous microorganisms in pre-H(2)O(2)-treated soil were also performed, and TPH removal efficiency of biodegradation was 48.5%, showing an improvement of 19.4% by biodegradation even after chemical oxidation. For a pilot scale feasibility test, a site contaminated with diesel (2.5 m × 2.7 m × 1 m) in Korea was selected, and five injection wells and one extraction well were installed in the site. After 0.3 pore volumes of 17.5% H(2)O(2) solution flushing for 15 days, TPH removal efficiency of the site was 51.5%. Seven days after the H(2)O(2) solution flushing was finished, a mixed indigenous microorganism cultured solution (43 L) was injected into the wells two times. After the injection of the cultured solution, the average concentration of TPH in the site decreased to 777 mg/kg, showing that an additional 19.6% of TPH was removed by biodegradation (total TPH removal efficiency: 71.1%). Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Hazen, T. C.; Faybishenko, B.; Beller, H. R.; Brodie, E. L.; Sonnenthal, E. L.; Steefel, C.; Larsen, J.; Conrad, M. E.; Bill, M.; Christensen, J. N.; Brown, S. T.; Joyner, D.; Borglin, S. E.; Geller, J. T.; Chakraborty, R.; Nico, P. S.; Long, P. E.; Newcomer, D. R.; Arntzen, E.
2011-12-01
The primary contaminant of concern in groundwater at the DOE Hanford 100 Area (Washington State) is hexavalent chromium [Cr(VI)] in Hanford coarse-grained sediments. Three lactate injections were conducted in March, August, and October 2010 at the Hanford 100-H field site to assess the efficacy of in situ Cr(VI) bioreductive immobilization. Each time, 55 gal of lactate solution was injected into the Hanford aquifer. To characterize the biogeochemical regimes before and after electron donor injection, we implemented a comprehensive plan of groundwater sampling for microbial, geochemical, and isotopic analyses. These tests were performed to provide evidence of transformation of toxic and soluble Cr(VI) into less toxic and poorly soluble Cr(III) by bioimmobilization, and to quantify critical and interrelated microbial metabolic and geochemical mechanisms affecting chromium in situ reductive immobilization and the long-term sustainability of chromium bioremediation. The results of lactate injections were compared with data from two groundwater biostimulation tests that were conducted in 2004 and 2008 by injecting Hydrogen Release Compound (HRC°), a slow-release glycerol polylactate, into the Hanford aquifer. In all HRC and lactate injection tests, 13C-labeled lactate was added to the injected solutions to track post-injection carbon pathways. Monitoring showed that despite a very low initial total microbial density (from <104 to 105 cells/mL), both HRC and lactate injections stimulated anaerobic microbial activity, which led to an increase in biomass to >107 cells/mL (including sulfate- and nitrate-reducing bacteria), resulting in a significant decrease in soluble Cr(VI) concentrations to below the MCL. In all tests, lactate was consumed nearly completely within the first week, much faster than HRC. Modeling of biogeochemical and isotope fractionation processes with the reaction-transport code TOUGHREACT captured the biodegradation of lactate, fermentative production of acetate and propionate, the evolution of 13C in bicarbonate, and the rate of sulfate reduction. In contrast to the slow-release HRC injections, no long-term effects of biostimulation and Cr bioreduction were observed in groundwater after the lactate injections. The presentation will address these patterns of the geochemical, δ13C of DIC, and biomass changes in groundwater before and after the polylactate and lactate injections.
Nagy, A; Bodò, G; Dyson, S J; Compostella, F; Barr, A R S
2010-09-01
Evidence-based information is limited on distribution of local anaesthetic solution following perineural analgesia of the palmar (Pa) and palmar metacarpal (PaM) nerves in the distal aspect of the metacarpal (Mc) region ('low 4-point nerve block'). To demonstrate the potential distribution of local anaesthetic solution after a low 4-point nerve block using a radiographic contrast model. A radiodense contrast medium was injected subcutaneously over the medial or the lateral Pa nerve at the junction of the proximal three-quarters and distal quarter of the Mc region (Pa injection) and over the ipsilateral PaM nerve immediately distal to the distal aspect of the second or fourth Mc bones (PaM injection) in both forelimbs of 10 mature horses free from lameness. Radiographs were obtained 0, 10 and 20 min after injection and analysed subjectively and objectively. Methylene blue and a radiodense contrast medium were injected in 20 cadaver limbs using the same techniques. Radiographs were obtained and the limbs dissected. After 31/40 (77.5%) Pa injections, the pattern of the contrast medium suggested distribution in the neurovascular bundle. There was significant proximal diffusion with time, but the main contrast medium patch never progressed proximal to the mid-Mc region. The radiological appearance of 2 limbs suggested that contrast medium was present in the digital flexor tendon sheath (DFTS). After PaM injections, the contrast medium was distributed diffusely around the injection site in the majority of the limbs. In cadaver limbs, after Pa injections, the contrast medium and the dye were distributed in the neurovascular bundle in 8/20 (40%) limbs and in the DFTS in 6/20 (30%) of limbs. After PaM injections, the contrast and dye were distributed diffusely around the injection site in 9/20 (45%) limbs and showed diffuse and tubular distribution in 11/20 (55%) limbs. Proximal diffusion of local anaesthetic solution after a low 4-point nerve block is unlikely to be responsible for decreasing lameness caused by pain in the proximal Mc region. The DFTS may be penetrated inadvertently when performing a low 4-point nerve block.
Nomura, Akira; Shin, Shigemitsu; Mehdi, Othman Oulad; Kauffmann, Jean-Michel
2004-09-15
Enzyme-immobilized magnetic microparticles (EMMP) have been prepared for use as a microreactor in flow injection analysis (FI). The microparticles were directly injected into the FI system. Their retention occurred within the flow line by small permanent magnets located near the detector. The analytical utility of this concept was illustrated by the assay of glucose using glucose oxidase (GOx), immobilized microparticles, and amperometric detection of liberated hydrogen peroxide. The microparticles were derived from silica gel (nominal pore diameter, 15-80 nm) by impregnation with a citric acid/ethanol solution and a ferric nitrate/ethanol solution and then by calcination in a nitrogen atmosphere to produce ferrimagnetic fine particles of spinel-type iron oxide (gamma-Fe(2)O(3)) inside the pore. They were characterized by X-ray diffraction. The calibration curve of the glucose sample (2 microL injected) was linear between 2.5 x 10(-6) and 5 x 10(-4) mol/L (R = 0.9995), and the detection limit was 1.0 x 10(-6) mol/L or 0.36 ng of injected glucose (S/N = 3). The repeatability for a 5 x 10(-4) mol/L glucose solution was RSD = 1.5% (n = 6). Application to the assay of glucose in a fermentation broth is illustrated. The GOx MMP were stable and active for more than eight months when kept at 10 degrees C.
Ferrieri, R.A.; Schlyer, D.J.; Alexoff, D.
1996-01-09
A handling and processing apparatus is revealed for preparing Oxygen-15 labeled water (H{sub 2}[{sup 15}O]) in injectable form for use in Positron Emission Tomography from preferably H{sub 2}[{sup 15}O] produced by irradiating a flowing gas target of nitrogen and hydrogen. The apparatus includes a collector for receiving and directing a gas containing H{sub 2}[{sup 15}O] gas and impurities, mainly ammonia (NH{sub 3}) gas into sterile water to trap the H{sub 2}[{sup 15}O] and form ammonium (NH{sub 4}{sup +}) in the sterile water. A device for displacing the sterile water containing H{sub 2}[{sup 15}O] and NH{sub 4}{sup +} through a cation resin removes NH{sub 4}{sup +} from the sterile water. A device for combining the sterile water containing H{sub 2}[{sup 15}O] with a saline solution produces an injectable solution. Preferably, the apparatus includes a device for delivering the solution to a syringe for injection into a patient. Also, disclosed is a method for preparing H{sub 2}[{sup 15}O] in injectable form for use in Positron Emission Tomography in which the method neither requires isotopic exchange reaction nor application of high temperature. 7 figs.
[Permanent tattoos following injections with Dermo-Jet: anatomoclinical study. Apropos of 5 cases].
Lachapelle, J M; Tennstedt, D; Burtonboy, G
1982-01-01
Blue or black tattoos were observed in five patients who had received several intradermal injections (of a lidocaine solution or of a triamcinolone acetonide suspension) with the Dermo-Jet. A histological examination revealed the presence of black masses, rounded or elongated, different in size, distributed throughout dermal tissue. Additionally, conglomerates of black grains in the cytoplasm of histiocytes and of pericytes are precisely observed in semi-thin sections. It has been proved by several investigations that these foreign particles are not of metallic nature. It can be concluded from electron microscopic studies that the particles are fragments of black rubber, from the upper joint of the reservoir. Indeed, some rubber fragments are leached into the reservoir. Some of these are passing through the wire-mesh filter of the nozzle (with the solution or the suspension) when injections are made. Therefore, they are injected intradermally and are permanently tattooing the skin.
Yura, Y; Tsujimoto, H; Kusaka, J; Harada, K; Yoshida, H; Sato, M
1995-03-01
To determine whether the local administration of 9,10-dimethyl-1,2-benzanthracene (DMBA) into the hamster maxillary sinus induced carcinoma at the injected site, hamsters were injected with 30 microliters of 0.5% solution of DMBA in dimethyl sulfoxide (DMSO) through the infraorbital foramen into the maxillary sinus once weekly for 10 weeks (Group 2). Another group of hamsters (Group 1) received similar injections of 30 microliters of DMSO only. In a third group of animals (Group 3), a roll of oxycellulose was inserted into the maxillary sinus and 40 microliters of a 2% solution of DMBA in DMSO was injected once. Sinonasal carcinomas were demonstrated in 73% (8/11) of the hamsters in Group 2 and sarcomas were shown in 73% (8/11) of the hamsters in Group 3, as well as some carcinomas. No tumors were seen in the Group 1 hamsters. Histologic examination revealed squamous cell carcinomas arising from the surface epithelium and submucous glands of the nasal cavity and maxillary sinus. These findings indicate that the intrasinal administration of a 0.5% solution of DMBA in DMSO is a reliable method for inducing maxillary sinus cancer.
NASA Astrophysics Data System (ADS)
Volkov, Sergei S.; Vasiliev, Andrey S.; Aizikovich, Sergei M.; Sadyrin, Evgeniy V.
2018-05-01
Indentation of an elastic half-space with functionally graded coating by a rigid flat punch is studied. The half-plane is additionally subjected to distributed tangential stresses. Tangential stresses are represented in a form of Fourier series. The problem is reduced to the solution of two dual integral equations over even and odd functions describing distribution of unknown normal contact stresses. The solutions of these dual integral equations are constructed by the bilateral asymptotic method. Approximated analytical expressions for contact normal stresses are provided.
Implementing the Gaia Astrometric Global Iterative Solution (AGIS) in Java
NASA Astrophysics Data System (ADS)
O'Mullane, William; Lammers, Uwe; Lindegren, Lennart; Hernandez, Jose; Hobbs, David
2011-10-01
This paper provides a description of the Java software framework which has been constructed to run the Astrometric Global Iterative Solution for the Gaia mission. This is the mathematical framework to provide the rigid reference frame for Gaia observations from the Gaia data itself. This process makes Gaia a self calibrated, and input catalogue independent, mission. The framework is highly distributed typically running on a cluster of machines with a database back end. All code is written in the Java language. We describe the overall architecture and some of the details of the implementation.
Steady-State Solution of a Flexible Wing
NASA Technical Reports Server (NTRS)
Karkehabadi, Reza; Chandra, Suresh; Krishnamurthy, Ramesh
1997-01-01
A fluid-structure interaction code, ENSAERO, has been used to compute the aerodynamic loads on a swept-tapered wing. The code has the capability of using Euler or Navier-Stokes equations. Both options have been used and compared in the present paper. In the calculation of the steady-state solution, we are interested in knowing how the flexibility of the wing influences the lift coefficients. If the results of a flexible wing are not affected by the flexibility of the wing significantly, one could consider the wing to be rigid and reduce the problem from fluid-structure interaction to a fluid problem.
Effect of geometry on hydrodynamic film thickness
NASA Technical Reports Server (NTRS)
Brewe, D. E.; Hamrock, B. J.; Taylor, C. M.
1978-01-01
The influence of geometry on the isothermal hydrodynamic film separating two rigid solids was investigated. Pressure-viscosity effects were not considered. The minimum film thickness is derived for fully flooded conjunctions by using the Reynolds conditions. It was found that the minimum film thickness had the same speed, viscosity, and load dependence as Kapitza's classical solution. However, the incorporation of Reynolds boundary conditions resulted in an additional geometry effect. Solutions using the parabolic film approximation are compared with those using the exact expression for the film in the analysis. Contour plots are shown that indicate in detail the pressure developed between the solids.
Effect of geometry on hydrodynamic film thickness
NASA Technical Reports Server (NTRS)
Brewe, D. E.; Hamrock, B. J.; Taylor, C. M.
1978-01-01
The influence of geometry on the isothermal hydrodynamic film separating two rigid solids was investigated. Pressure-viscosity effects were not considered. The minimum film thickness is derived for fully flooded conjunctions by using the Reynolds boundary conditions. It was found that the minimum film thickness had the same speed, viscosity, and load dependence as Kapitza's classical solution. However, the incorporation of Reynolds boundary conditions resulted in an additional geometry effect. Solutions using the parabolic film approximation are compared with those using the exact expression for the film in the analysis. Contour plots are shown that indicate in detail the pressure developed between the solids.
Karadağ, Sevinç; Görüşük, Emine M; Çetinkaya, Ebru; Deveci, Seda; Dönmez, Koray B; Uncuoğlu, Emre; Doğu, Mustafa
2018-01-25
A fully automated flow injection analysis (FIA) system was developed for determination of phosphate ion in nutrient solutions. This newly developed FIA system is a portable, rapid and sensitive measuring instrument that allows on-line analysis and monitoring of phosphate ion concentration in nutrient solutions. The molybdenum blue method, which is widely used in FIA phosphate analysis, was adapted to the developed FIA system. The method is based on the formation of ammonium Mo(VI) ion by reaction of ammonium molybdate with the phosphate ion present in the medium. The Mo(VI) ion then reacts with ascorbic acid and is reduced to the spectrometrically measurable Mo(V) ion. New software specific for flow analysis was developed in the LabVIEW development environment to control all the components of the FIA system. The important factors affecting the analytical signal were identified as reagent flow rate, injection volume and post-injection flow path length, and they were optimized using Box-Behnken experimental design and response surface methodology. The optimum point for the maximum analytical signal was calculated as 0.50 mL min -1 reagent flow rate, 100 µL sample injection volume and 60 cm post-injection flow path length. The proposed FIA system had a sampling frequency of 100 samples per hour over a linear working range of 3-100 mg L -1 (R 2 = 0.9995). The relative standard deviation (RSD) was 1.09% and the limit of detection (LOD) was 0.34 mg L -1 . Various nutrient solutions from a tomato-growing hydroponic greenhouse were analyzed with the developed FIA system and the results were found to be in good agreement with vanadomolybdate chemical method findings. © 2018 Society of Chemical Industry. © 2018 Society of Chemical Industry.
NASA Astrophysics Data System (ADS)
Bandilla, K.; Kraemer, S. R.
2009-12-01
Injection of carbon dioxide into deep saline formations is seen as one possible technology for mitigating carbon emissions from utilities. The safety of the sequestered carbon dioxide is the focus of many studies with leakage through faults or abandoned wells as some of the main failure mechanisms. The focus of this study is on the displacement of resident brine and the resulting changes in pressure due to the injection of large volumes of super-critical phase carbon dioxide into the subsurface. The movement of brine becomes important if it travels vertically and reaches an existing or potential underground source of drinking water where an increase in salt content may threaten the viability of the drinking water source. Vertical displacement of brine may occur slowly through confining layers, or more rapidly through faults and abandoned wells. This presentation compares several (semi-) analytic solutions to determine their applicability to the problem of brine pressurization and displacement. The goal is to find ranges of formation parameters (e.g., formation seal conductivity, distance to lateral boundary, … ) for which simplifying assumption are justifiable Each simplification in the conceptual model (e.g., neglecting the lateral boundary turns a bounded domain into an infinite one) leads to a simpler (semi-) analytic solution. The process involves a solution hierarchy from the most complex solution down to the basic Theis solution. A software tool-kit implementing several (semi-) analytic solutions was developed for this study to facilitate the comparison of the solutions.
Polymers And Riblets Reduce Hydrodynamic Skin Friction
NASA Technical Reports Server (NTRS)
Bushnell, Dennis M.; Reed, Jason C.
1991-01-01
Polymers injected into riblet grooves dramatically reduce polymer flow rate required for drag reduction. Polymer solution injected into valleys of grooves through array of holes or slots angled downstream to keep injected streams within grooves. Injection repeated some distance downstream because volumes of grooves finite and polymer becomes depleted as slowly pulled from groove by turbulence. Potentially useful for oil tankers as means of markedly reducing cost of fuel and used extensively on submarines, other ships, and other marine vehicles.
Induction of Contraception by Intraepididymal Sclerotherapy
Park, Hyoung Keun; Paick, Sung Hyun; Kim, Hyeong Gon; Lho, Yong Soo
2014-01-01
Purpose The objective of the present study was to evaluate the efficacy of a sclerosing solution for inducing epididymal occlusion in male rats. Materials and Methods Male Sprague-Dawley rats were divided into two groups: an injection group (n=20) and control group (n=20). Before injecting the sclerosing agent, seminal vesiculectomy and sperm identification using electrostimulation were performed in all of the rats. In the injection group, 0.2 mL of 0.1% sodium tetradecyl sulfate solution was injected into the epididymis. In the sham group, only the identification of the epididymis was performed. At 4 and 12 weeks after the injection, semen was collected by electrostimulation and evaluated to assess the contraceptive effect. Epididymis was evaluated by hematoxylin and eosin (H&E) staining. Results After 4 and 12 weeks, semen collection was performed in the two groups. Sperms were not observed in the injection group, while there was no change in the sperms in the sham group. H&E staining showed the obstruction of epididymal tubules and an accumulation of inflammatory cells in the injection group. Conclusions This study showed that the sclerosing agent induced sterilization in male rats. This result suggests that the injection method can replace vasectomy as a contraceptive method. However, a further study of large animals and a clinical study are needed. Further, the long-term effectiveness of this method needs to be studied. PMID:25237657
A Novel Concept for Safe, Stiffness-Controllable Robot Links.
Stilli, Agostino; Wurdemann, Helge A; Althoefer, Kaspar
2017-03-01
The recent decade has seen an astounding increase of interest and advancement in a new field of robotics, aimed at creating structures specifically for the safe interaction with humans. Softness, flexibility, and variable stiffness in robotics have been recognized as highly desirable characteristics for many applications. A number of solutions were proposed ranging from entirely soft robots (such as those composed mainly from soft materials such as silicone), via flexible continuum and snake-like robots, to rigid-link robots enhanced by joints that exhibit an elastic behavior either implemented in hardware or achieved purely by means of intelligent control. Although these are very good solutions paving the path to safe human-robot interaction, we propose here a new approach that focuses on creating stiffness controllability for the linkages between the robot joints. This article proposes a replacement for the traditionally rigid robot link-the new link is equipped with an additional capability of stiffness controllability. With this added feature, a robot can accurately carry out manipulation tasks (high stiffness), but can virtually instantaneously reduce its stiffness when a human is nearby or in contact with the robot. The key point of the invention described here is a robot link made of an airtight chamber formed by a soft and flexible, but high-strain resistant combination of a plastic mesh and silicone wall. Inflated with air to a high pressure, the mesh silicone chamber behaves like a rigid link; reducing the air pressure, softens the link and rendering the robot structure safe. This article investigates a number of link prototypes and shows the feasibility of the new concept. Stiffness tests have been performed, showing that a significant level of stiffness can be achieved-up to 40 N reaction force along the axial direction, for a 25-mm-diameter sample at 60 kPa, at an axial deformation of 5 mm. The results confirm that this novel concept to linkages for robot manipulators exhibits the beam-like behavior of traditional rigid links when fully pressurized and significantly reduced stiffness at low pressure. The proposed concept has the potential to easily create safe robots, augmenting traditional robot designs.
Quantification of CO2-FLUID-ROCK Reactions Using Reactive and Non-Reactive Tracers
NASA Astrophysics Data System (ADS)
Matter, J.; Stute, M.; Hall, J. L.; Mesfin, K. G.; Gislason, S. R.; Oelkers, E. H.; Sigfússon, B.; Gunnarsson, I.; Aradottir, E. S.; Alfredsson, H. A.; Gunnlaugsson, E.; Broecker, W. S.
2013-12-01
Carbon dioxide mineralization via fluid-rock reactions provides the most effective and long-term storage option for geologic carbon storage. Injection of CO2 in geologic formations induces CO2 -fluid-rock reactions that may enhance or decrease the storage permanence and thus the long-term safety of geologic carbon storage. Hence, quantitative characterization of critical CO2 -fluid-rock interactions is essential to assess the storage efficiency and safety of geologic carbon storage. In an attempt to quantify in-situ fluid-rock reactions and CO2 transport relevant for geologic carbon storage, we are testing reactive (14C, 13C) and non-reactive (sodium fluorescein, amidorhodamine G, SF5CF3, and SF6) tracers in an ongoing CO2 injection in a basaltic storage reservoir at the CARBFIX pilot injection site in Iceland. At the injection site, CO2 is dissolved in groundwater and injected into a permeable basalt formation located 500-800 m below the surface [1]. The injected CO2 is labeled with 14C by dynamically adding calibrated amounts of H14CO3-solution into the injection stream in addition to the non-reactive tracers. Chemical and isotopic analyses of fluid samples collected in a monitoring well, reveal fast fluid-rock reactions. Maximum SF6 concentration in the monitoring well indicates the bulk arrival of the injected CO2 solution but dissolved inorganic carbon (DIC) concentration and pH values close to background, and a potentially lower 14C to SF6 ratio than the injection ratio suggest that most of the injected CO2 has reacted with the basaltic rocks. This is supported by δ13CDIC, which shows a drop from values close to the δ 13C of the injected CO2 gas (-3‰ VPDB) during breakthrough of the CO2 plume to subsequent more depleted values (-11.25‰ VPDB), indicating precipitation of carbonate minerals. Preliminary mass balance calculations using mixing relationships between the background water in the storage formation and the injected solution, suggest that approximately 85% of the injected CO2 must have reacted along the flow path from the injection well to the monitoring well within less than one year. Monitoring is still going on and we will extend the time series and the mass balance accordingly. Our study demonstrates that by combining reactive and non-reactive tracers, we are able to quantify CO2-fluid-rock interactions on a reservoir scale. [1] Gislason et al. (2010), Int. J. Greenh. Gas Con. 4, 537-545.
Plasma response to sustainment with imposed-dynamo current drive in HIT-SI and HIT-SI3
NASA Astrophysics Data System (ADS)
Hossack, A. C.; Jarboe, T. R.; Chandra, R. N.; Morgan, K. D.; Sutherland, D. A.; Penna, J. M.; Everson, C. J.; Nelson, B. A.
2017-07-01
The helicity injected torus—steady inductive (HIT-SI) program studies efficient, steady-state current drive for magnetic confinement plasmas using a novel experimental method. Stable, high-beta spheromaks have been sustained using steady, inductive current drive. Externally induced loop voltage and magnetic flux are oscillated together so that helicity and power injection are always positive, sustaining the edge plasma current indefinitely. Imposed-dynamo current drive (IDCD) theory further shows that the entire plasma current is sustained. The method is ideal for low aspect ratio, toroidal geometries with closed flux surfaces. Experimental studies of spheromak plasmas sustained with IDCD have shown stable magnetic profiles with evidence of pressure confinement. New measurements show coherent motion of a stable spheromak in response to the imposed perturbations. On the original device two helicity injectors were mounted on either side of the spheromak and the injected mode spectrum was predominantly n = 1. Coherent, rigid motion indicates that the spheromak is stable and a lack of plasma-generated n = 1 energy indicates that the maximum q is maintained below 1 during sustainment. Results from the HIT-SI3 device are also presented. Three inductive helicity injectors are mounted on one side of the spheromak flux conserver. Varying the relative injector phasing changes the injected mode spectrum which includes n = 2, 3, and higher modes.
NASA Astrophysics Data System (ADS)
Hur, Soojung Claire
2013-11-01
Inertial effects in microfluidic systems have recently recognized as a robust and passive way of focusing and ordering microscale particles and cells continuously. Moreover, theoretical analysis has shown that there exists a force away from channel walls in Poiseuille flow that locates deformable particles closer to the channel center than rigid counterparts. Then, the particle deformability can be extrapolated from the positions of particles with known sizes in the channel. Here, behaviors of various viscous droplets in inertial flow were investigated to identify critical properties determining their dynamic lateral position. Fluorinated oil solutions (μ = 1.7 mPas and 5 mPas) containing droplets (1mPas< μ<1.3Pas) were injected into a microfluidic channel with a syringe pump (8 < Rc < 50). Interfacial tension between aqueous and oil phases were varied by adding controlled amount of a surfactant. The diameter, a, deformability, Def, and dynamic lateral position, Xeq, were determined using high-speed microscopy. Xeq, was found to correlate with the particle Capillary Number, CaP, regardless of droplet viscosities when CaP <0.02 or CaP >0.2, suggesting that the viscous drag from the continuous phase and the interfacial tension were competing factors determining Xeq. Experimental results suggested that (i) interplay among droplet's viscosity, interfacial tension and inertia of carrier fluid determines dynamic lateral position of droplets and (ii) the dominant property varies at a different regime.
Mohtashamian, Shahab; Boddohi, Soheil; Hosseinkhani, Saman
2018-02-01
Self-assembled nanogel was prepared by electrostatic complexation of two oppositely charged biological macromolecules, which were cationic nisin and anionic chondroitin sulfate (ChS). The critical factors affected the physical properties of ChS-nisin nanogel was screened and optimized by Plackett-Burman design (PB) and central composite design (CCD). The independent factors selected were: concentration ratio of nisin to ChS, injection rate of nisin solution, buffer solvent type, magnetic stirring rate, pH of initial buffer solution, centrifuge-cooling temperature, and centrifuge rotation speed. Among these factors, concentration ratio changed the entrapment efficiency and loading capacity significantly. In addition, the hydrodynamic diameter and loading capacity were significantly influenced by injection rate and pH of initial buffer solution. The optimized nanogel structure was obtained by concentration ratio of 6.4mg/mL nisin to 1mg/mL ChS, pH of buffer solution at 4.6, and nisin solution injection rate of 0.2mL/min. The observed values of dependent responses were close to predicted values confirmed by model from response surface methodology. The results obviously showed that quality by design concept (QbD) could be effectively applied to optimize the developed ChS-nisin nanogel. Copyright © 2017 Elsevier B.V. All rights reserved.
Waterflooding employing surfactants derived from metallic soaps
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, S.A.
1975-12-16
A waterflooding process is described in which a petroleum oil containing divalent metal soaps is contacted with an inorganic acid in order to convert the soaps to the corresponding organic acids. The organic acids thus obtained may be injected into the reservoir followed by an aqueous alkaline solution. Alternatively, the organic acids may be contacted with an aqueous solution in order to convert the acids to the corresponding surface-active monovalent salts, which may be then injected into the reservoir. (4 claims)
Exact solution for flow in a porous pipe with unsteady wall suction and/or injection
NASA Astrophysics Data System (ADS)
Tsangaris, S.; Kondaxakis, D.; Vlachakis, N. W.
2007-10-01
This paper presents an extension of the exact solution of the steady laminar axisymmetric flow in a straight pipe of circular cross section with porous wall, given by R.M. Terrill, to the case of unsteady wall injection and/or suction. The cases of the pulsating parabolic profile and of the developed pulsating flow are investigated as examples. The pulsating flow in porous ducts has many applications in biomedical engineering and in other engineering areas.
Shi, Shenglong; Wang, Yefei; Li, Zhongpeng; Chen, Qingguo; Zhao, Zenghao
Colloidal Gas Aphron as a mobility control in enhanced oil recovery is becoming attractive; it is also designed to block porous media with micro-bubbles. In this paper, the effects of surfactant concentration, polymer concentration, temperature and salinity on the bubble size of the Colloidal Gas Aphron were studied. Effects of injection rates, Colloidal Gas Aphron fluid composition, heterogeneity of reservoir on the resistance to the flow of Colloidal Gas Aphron fluid through porous media were investigated. Effects of Colloidal Gas Aphron fluid composition and temperature on residual oil recovery were also studied. The results showed that bubble growth rate decreased with increasing surfactant concentration, polymer concentration, and decreasing temperature, while it decreased and then increased slightly with increasing salinity. The obvious increase of injection pressure was observed as more Colloidal Gas Aphron fluid was injected, indicating that Colloidal Gas Aphron could block the pore media effectively. The effectiveness of the best blend obtained through homogeneous sandpack flood tests was modestly improved in the heterogeneous sandpack. The tertiary oil recovery increased 26.8 % by Colloidal Gas Aphron fluid as compared to 20.3 % by XG solution when chemical solution of 1 PV was injected into the sandpack. The maximum injected pressure of Colloidal Gas Aphron fluid was about three times that of the XG solution. As the temperature increased, the Colloidal Gas Aphron fluid became less stable; the maximum injection pressure and tertiary oil recovery of Colloidal Gas Aphron fluid decreased.
Kennedy, V.C.; Jackman, A.P.; Zand, S.M.; Zellweger, G.W.; Avanzino, R.J.
1984-01-01
Stream sediments adsorb certain solutes from streams, thereby significantly changing the solute composition; but little is known about the details and rates of these adsorptive processes. To investigate such processes, a 24-hr. injection of a solution containing chloride, strontium, potassium, sodium and lead was made at the head of a 640-m reach of Uvas Creek in west-central Santa Clara County, California. Uvas Creek is a cobble-bed pool-and-riffle stream draining the eastern slopes of the Santa Cruz Mountains. By September 12, 1973, after a long dry season, Uvas Creek had a low (0.0215 m3s-1 average) flow which varied diurnally, from 0.018 to 0.025 m3s-1. Because stream discharge varied while the injection rate was constant, the concentration of tracers (injected solutes), after mixing in the stream, varied inversely with discharge. Chloride, a nonreactive solute, served as a tracer of water movement. Analysis of extensive chloride concentration data at five sites below the injection point during and after the injection demonstrated that there was considerable underflow of water through the stream gravels; however, the extent of underflow varied greatly within the study reach. Pre-injection water, displaced by tracer-laden water percolating through the gravels, diluted tracers in the stream channel, giving the mistaken impression of groundwater inflow at some points. Accurate measurement of total discharge in such streams requires prolonged tracer injection unless a reach can be found where underflow is negligible. Strontium and potassium were adsorbed by the bed sediments to a moderate extent and lead was strongly adsorbed. A high proportion of these metals could be removed by adsorption from percolating underflow because of extensive and intimate contact with bed sediments. After channel clearing following injection cutoff, 51% of the added strontium and 96% of the lead remained in the study reach, whereas only 19% of the chloride remained. Packets of sized sediment, placed in the stream before the experiment and withdrawn during and after the injection, indicated that the strontium absorbed on the 0.42-0.50-mm size sediment appeared to achieve near equilibrium with dissolved strontium within less than 2 hr. whereas 3.4-4.0-mm grains had not reached that stage after 24 hr. The cation-exchange capacity (CEC) of the sediments shows a "bimodal" distribution with grain size. Largest values are in the finest sizes, lower values in the fine-to-medium sand-size range, intermediate values in the coarse- to very coarse-grained sand, and decreasing values with size above very coarse-grained sand. This considerable exchange capacity in coarse-sand to granule-size particles means that a streambed, that has not been infilled with fines to reduce permeability, can be highly reactive and accessible throughout a rather thick sediment layer and hence have a large and available reactive capacity. As stream discharge increases from low flow, the ratio of underflow to channel flow should decrease rapidly with resultant diminution in percent of solutes sorbed within a particular stream reach. ?? 1984.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hyman, Jeffrey De'Haven; Painter, S. L.; Viswanathan, H.
We investigate how the choice of injection mode impacts transport properties in kilometer-scale three-dimensional discrete fracture networks (DFN). The choice of injection mode, resident and flux-weighted, is designed to mimic different physical phenomena. It has been hypothesized that solute plumes injected under resident conditions evolve to behave similarly to solutes injected under flux-weighted conditions. Previously, computational limitations have prohibited the large-scale simulations required to investigate this hypothesis. We investigate this hypothesis by using a high-performance DFN suite, dfnWorks, to simulate flow in kilometer-scale three-dimensional DFNs based on fractured granite at the Forsmark site in Sweden, and adopt a Lagrangian approachmore » to simulate transport therein. Results show that after traveling through a pre-equilibrium region, both injection methods exhibit linear scaling of the first moment of travel time and power law scaling of the breakthrough curve with similar exponents, slightly larger than 2. Lastly, the physical mechanisms behind this evolution appear to be the combination of in-network channeling of mass into larger fractures, which offer reduced resistance to flow, and in-fracture channeling, which results from the topology of the DFN.« less
Hyman, Jeffrey De'Haven; Painter, S. L.; Viswanathan, H.; ...
2015-09-12
We investigate how the choice of injection mode impacts transport properties in kilometer-scale three-dimensional discrete fracture networks (DFN). The choice of injection mode, resident and flux-weighted, is designed to mimic different physical phenomena. It has been hypothesized that solute plumes injected under resident conditions evolve to behave similarly to solutes injected under flux-weighted conditions. Previously, computational limitations have prohibited the large-scale simulations required to investigate this hypothesis. We investigate this hypothesis by using a high-performance DFN suite, dfnWorks, to simulate flow in kilometer-scale three-dimensional DFNs based on fractured granite at the Forsmark site in Sweden, and adopt a Lagrangian approachmore » to simulate transport therein. Results show that after traveling through a pre-equilibrium region, both injection methods exhibit linear scaling of the first moment of travel time and power law scaling of the breakthrough curve with similar exponents, slightly larger than 2. Lastly, the physical mechanisms behind this evolution appear to be the combination of in-network channeling of mass into larger fractures, which offer reduced resistance to flow, and in-fracture channeling, which results from the topology of the DFN.« less
Grounding electrode and method of reducing the electrical resistance of soils
Koehmstedt, Paul L.
1980-01-01
A first solution of an electrolyte is injected underground into a volume of soil having negative surface charges on its particles. A cationic surfactant suspended in this solution neutralizes these surface charges of the soil particles within the volume. Following the first solution, a cationic asphalt emulsion suspended in a second solution is injected into the volume. The asphalt emulsion diffuses through the volume and electrostatically bonds with additional soil surrounding the volume such that an electrically conductive water repellant shell enclosing the volume is formed. This shell prevents the leaching of electrolyte from the volume into the additional soil. The second solution also contains a dissolved deliquescent salt which draws water into the volume prior to the formation of the shell. When electrically connected to an electrical installation such as a power line tower, the volume constitutes a grounding electrode for the tower.
Integrated vacuum absorption steam cycle gas separation
Chen, Shiaguo [Champaign, IL; Lu, Yonggi [Urbana, IL; Rostam-Abadi, Massoud [Champaign, IL
2011-11-22
Methods and systems for separating a targeted gas from a gas stream emitted from a power plant. The gas stream is brought into contact with an absorption solution to preferentially absorb the targeted gas to be separated from the gas stream so that an absorbed gas is present within the absorption solution. This provides a gas-rich solution, which is introduced into a stripper. Low pressure exhaust steam from a low pressure steam turbine of the power plant is injected into the stripper with the gas-rich solution. The absorbed gas from the gas-rich solution is stripped in the stripper using the injected low pressure steam to provide a gas stream containing the targeted gas. The stripper is at or near vacuum. Water vapor in a gas stream from the stripper is condensed in a condenser operating at a pressure lower than the stripper to concentrate the targeted gas. Condensed water is separated from the concentrated targeted gas.
Buffered lidocaine and bupivacaine mixture - the ideal local anesthetic solution?
Best, Corliss A; Best, Alyssa A; Best, Timothy J; Hamilton, Danielle A
2015-01-01
The use of injectable local anesthetic solutions to facilitate pain-free surgery is an integral component of many procedures performed by the plastic surgeon. In many instances, a solution that has both rapid onset and prolonged duration of analgesia is optimal. A combination of lidocaine and bupivacaine, plain or with epinephrine, is readily available in most Canadian health care settings where such procedures are performed, and fulfills these criteria. However, commercially available solutions of both medications are acidic and cause a burning sensation on injection. Buffering to neutral pH with sodium bicarbonate is a practical method to mitigate the burning sensation, and has the added benefit of increasing the fraction of nonionized lipid soluble drug available. The authors report on the proportions of the three drugs to yield a neutral pH, and the results of an initial survey regarding the use of the combined solution with epinephrine in hand surgery.
Fujisawa, Jun-Ichi; Osawa, Ayumi; Hanaya, Minoru
2016-08-10
Photoinduced carrier injection from dyes to inorganic semiconductors is a crucial process in various dye-sensitized solar energy conversions such as photovoltaics and photocatalysis. It has been reported that an energy offset larger than 0.2-0.3 eV (threshold value) is required for efficient electron injection from excited dyes to metal-oxide semiconductors such as titanium dioxide (TiO2). Because the energy offset directly causes loss in the potential of injected electrons, it is a crucial issue to minimize the energy offset for efficient solar energy conversions. However, a fundamental understanding of the energy offset, especially the threshold value, has not been obtained yet. In this paper, we report the origin of the threshold value of the energy offset, solving the long-standing questions of why such a large energy offset is necessary for the electron injection and which factors govern the threshold value, and suggest a strategy to minimize the threshold value. The threshold value is determined by the sum of two reorganization energies in one-electron reduction of semiconductors and typically-used donor-acceptor (D-A) dyes. In fact, the estimated values (0.21-0.31 eV) for several D-A dyes are in good agreement with the threshold value, supporting our conclusion. In addition, our results reveal that the threshold value is possible to be reduced by enlarging the π-conjugated system of the acceptor moiety in dyes and enhancing its structural rigidity. Furthermore, we extend the analysis to hole injection from excited dyes to semiconductors. In this case, the threshold value is given by the sum of two reorganization energies in one-electron oxidation of semiconductors and D-A dyes.
75 FR 1274 - Implantation or Injectable Dosage Form New Animal Drugs; Hyaluronate Sodium
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-11
... safety warning for use of hyaluronate sodium injectable solution in horses. DATES: This rule is effective... human food safety warning on product labeling. The supplemental NADA is approved as of December 11, 2009...