Stratis, Andreas; Zhang, Guozhi; Lopez-Rendon, Xochitl; Politis, Constantinus; Hermans, Robert; Jacobs, Reinhilde; Bogaerts, Ria; Shaheen, Eman; Bosmans, Hilde
2017-09-01
To calculate organ doses and estimate the effective dose for justification purposes in patients undergoing orthognathic treatment planning purposes and temporal bone imaging in dental cone beam CT (CBCT) and Multidetector CT (MDCT) scanners. The radiation dose to the ICRP reference male voxel phantom was calculated for dedicated orthognathic treatment planning acquisitions via Monte Carlo simulations in two dental CBCT scanners, Promax 3D Max (Planmeca, FI) and NewTom VGi evo (QR s.r.l, IT) and in Somatom Definition Flash (Siemens, DE) MDCT scanner. For temporal bone imaging, radiation doses were calculated via MC simulations for a CBCT protocol in NewTom 5G (QR s.r.l, IT) and with the use of a software tool (CT-expo) for Somatom Force (Siemens, DE). All procedures had been optimized at the acceptance tests of the devices. For orthognathic protocols, dental CBCT scanners deliver lower doses compared to MDCT scanners. The estimated effective dose (ED) was 0.32mSv for a normal resolution operation mode in Promax 3D Max, 0.27mSv in VGi-evo and 1.18mSv in the Somatom Definition Flash. For temporal bone protocols, the Somatom Force resulted in an estimated ED of 0.28mSv while for NewTom 5G the ED was 0.31 and 0.22mSv for monolateral and bilateral imaging respectively. Two clinical exams which are carried out with both a CBCT or a MDCT scanner were compared in terms of radiation dose. Dental CBCT scanners deliver lower doses for orthognathic patients whereas for temporal bone procedures the doses were similar. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Lundin, Margareta; Lidén, Mats; Magnuson, Anders; Mohammed, Ahmed Abdulilah; Geijer, Håkan; Andersson, Torbjörn; Persson, Anders
2012-07-01
Dual-energy computed tomography (DECT) has been shown to be useful for subtracting bone or calcium in CT angiography and gives an opportunity to produce a virtual non-contrast-enhanced (VNC) image from a series where contrast agents have been given intravenously. High noise levels and low resolution have previously limited the diagnostic value of the VNC images created with the first generation of DECT. With the recent introduction of a second generation of DECT, there is a possibility of obtaining VNC images with better image quality at hopefully lower radiation dose compared to the previous generation. To compare the image quality of the single-energy series to a VNC series obtained with a two generations of DECT scanners. CT of the urinary tract was used as a model. Thirty patients referred for evaluation of hematuria were examined with an older system (Somatom Definition) and another 30 patients with a new generation (Somatom Definition Flash). One single-energy series was obtained before and one dual-energy series after administration of intravenous contrast media. We created a VNC series from the contrast-enhanced images. Images were assessed concerning image quality with a visual grading scale evaluation of the VNC series with the single-energy series as gold standard. The image quality of the VNC images was rated inferior to the single-energy variant for both scanners, OR 11.5-67.3 for the Definition and OR 2.1-2.8 for the Definition Flash. Visual noise and overall quality were regarded as better with Flash than Definition. Image quality of VNC images obtained with the new generation of DECT is still slightly inferior compared to native images. However, the difference is smaller with the new compared to the older system.
Westwood, Marie E; Raatz, Heike D I; Misso, Kate; Burgers, Laura; Redekop, Ken; Lhachimi, Stefan K; Armstrong, Nigel; Kleijnen, Jos
2013-05-01
To assess the diagnostic performance of dual-source cardiac (DSC) computed tomography (CT) newer-generation CT instruments for identifying anatomically significant coronary artery disease (CAD) in patients who are difficult to image by using 64-section CT. A literature search comprised bibliographic databases (January 1, 2000, to March 22, 2011, with a pragmatic update on September 6, 2012), trial registries, and conference proceedings. Only studies using invasive coronary angiography as reference standard were included. Risk of bias was assessed (QUADAS-2). Results were stratified according to patient group on the basis of clinical characteristics. Summary estimates of sensitivity and specificity of DSC CT for detecting 50% or greater arterial stenosis were calculated by using a bivariate summary receiver operating characteristic or random-effects model. Twenty-five studies reported accuracy of DSC CT for diagnosing CAD in difficult to image patients; in 22 studies, one of two CT units of the same manufacturer (Somatom Definition or Somatom Definition Flash) was used, and in the remaining three, a different CT unit of another manufacturer (Aquilion One) was used. The pooled, per-patient estimates of sensitivity were 97.7% (95% confidence interval [CI]: 88.0%, 99.9%) and 97.7% (95% CI: 93.2%, 99.3%) for patients with arrhythmias and high heart rates, respectively. The corresponding pooled estimates of specificity were 81.7% (95% CI: 71.6%, 89.4%) and 86.3% (95% CI: 80.2%, 90.7%), respectively. All data were acquired by using Somatom Definition. In two studies with Somatom and one study with Aquilion One, sensitivity estimates of 90% or greater were reported in patients with previous stent implantations; specificities were 81.7% and 89.5% for Somatom and 81.0% for Aquilion One. In patients with high coronary calcium scores, previous bypass grafts, or obesity, only per-segment or per-artery data were available. Sensitivity estimates remained high (>90% in all but one study), and specificities ranged from 79.1% to 100%. All data were acquired by using Somatom Definition. DSC CT may be sufficiently accurate to diagnose clinically significant CAD in some or all difficult to image patients. http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.13121136/-/DC1. © RSNA, 2013.
Guberina, Nika; Forsting, Michael; Ringelstein, Adrian
2017-06-15
To evaluate the dose-reduction potential with different lens protectors for patients undergoing cranial computed tomography (CT) scans. Eye lens dose was assessed in vitro (α-Al2O3:C thermoluminescence dosemeters) using an Alderson-Rando phantom® in cranial CT protocols at different CT scanners (SOMATOM-Definition-AS+®(CT1) and SOMATOM-Definition-Flash® (CT2)) using two different lens-protection systems (Somatex® (SOM) and Medical Imaging Systems® (MIS)). Summarised percentage of the transmitted photons: (1) CT1 (a) unenhanced CT (nCT) with gantry angulation: SOM = 103%, MIS = 111%; (2) CT2 (a) nCT without gantry angulation: SOM = 81%, MIS = 91%; (b) CT angiography (CTA) with automatic dose-modulation technique: SOM = 39%, MIS = 74%; (c) CTA without dose-modulation technique: SOM = 22%, MIS = 48%; (d) CT perfusion: SOM = 44%, MIS = 69%. SOM showed a higher dose-reduction potential than MIS maintaining equal image quality. Lens-protection systems are most effective in CTA protocols without dose-reduction techniques. Lens-protection systems lower the average eye lens dose during CT scans up to 1/3 (MIS) and 2/3 (SOM), respectively, if the eye lens is exposed to the direct beam of radiation. Considering both the CT protocol and the material of lens protectors, they seem to be mandatory for reducing the radiation exposure of the eye lens. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Stress Computed Tomography Myocardial Perfusion Imaging: A New Topic in Cardiology.
Seitun, Sara; Castiglione Morelli, Margherita; Budaj, Irilda; Boccalini, Sara; Galletto Pregliasco, Athena; Valbusa, Alberto; Cademartiri, Filippo; Ferro, Carlo
2016-02-01
Since its introduction about 15 years ago, coronary computed tomography angiography has become today the most accurate clinical instrument for noninvasive assessment of coronary atherosclerosis. Important technical developments have led to a continuous stream of new clinical applications together with a significant reduction in radiation dose exposure. Latest generation computed tomography scanners (≥ 64 slices) allow the possibility of performing static or dynamic perfusion imaging during stress by using coronary vasodilator agents (adenosine, dipyridamole, or regadenoson), combining both functional and anatomical information in the same examination. In this article, the emerging role and state-of-the-art of myocardial computed tomography perfusion imaging are reviewed and are illustrated by clinical cases from our experience with a second-generation dual-source 128-slice scanner (Somatom Definition Flash, Siemens; Erlangen, Germany). Technical aspects, data analysis, diagnostic accuracy, radiation dose and future prospects are reviewed. Copyright © 2015 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duan, X; Grimes, J; Yu, L
Purpose: Focal spot blooming is an increase in the focal spot size at increased tube current and/or decreased tube potential. In this work, we evaluated the influence of tube current on the focal spot size at low kV for two CT systems, one of which used a tube designed to reduce blooming effects. Methods: A slit camera (10 micron slit) was used to measure focal spot size on two CT scanners from the same manufacturer (Siemens Somatom Force and Definition Flash) at 70 kV and low, medium and maximum tube currents, according to the capabilities of each system (Force: 100,more » 800 and 1300 mA; Flash: 100, 200 and 500 mA). Exposures were made with a stationary tube in service mode using a raised stand without table movement or flying focal spot technique. Focal spot size, nominally 0.8 and 1.2 mm, respectively, was measured parallel and perpendicular to the cathode-anode axis by calculating the full-width-at-half-maximum of the slit profile recording using computed radiographic plates. Results: Focal spot sizes perpendicular to the anode-cathode axis increased at the maximum mA by 5.7% on the Force and 39.1% on the Flash relative to that at the minimal mA, even though the mA was increased 13-fold on the Force and only 5- fold on the Flash. Focal spot size increased parallel to the anode-cathode axis by 70.4% on Force and 40.9% on Flash. Conclusion: For CT protocols using low kV, high mA is typically required. These protocols are relevant in children and smaller adults, and for dual-energy scanning. Technical measures to limit focal spot blooming are important in these settings to avoid reduced spatial resolution. The x-ray tube on a recently-introduced scanner appears to greatly reduce blooming effects, even at very high mA values. CHM has research support from Siemens Healthcare.« less
NASA Astrophysics Data System (ADS)
Tian, Xiaoyu; Li, Xiang; Segars, W. Paul; Frush, Donald P.; Samei, Ehsan
2012-03-01
The purpose of this work was twofold: (a) to estimate patient- and cohort-specific radiation dose and cancer risk index for abdominopelvic computer tomography (CT) scans; (b) to evaluate the effects of patient anatomical characteristics (size, age, and gender) and CT scanner model on dose and risk conversion coefficients. The study included 100 patient models (42 pediatric models, 58 adult models) and multi-detector array CT scanners from two commercial manufacturers (LightSpeed VCT, GE Healthcare; SOMATOM Definition Flash, Siemens Healthcare). A previously-validated Monte Carlo program was used to simulate organ dose for each patient model and each scanner, from which DLP-normalized-effective dose (k factor) and DLP-normalized-risk index values (q factor) were derived. The k factor showed exponential decrease with increasing patient size. For a given gender, q factor showed exponential decrease with both increasing patient size and patient age. The discrepancies in k and q factors across scanners were on average 8% and 15%, respectively. This study demonstrates the feasibility of estimating patient-specific organ dose and cohort-specific effective dose and risk index in abdominopelvic CT requiring only the knowledge of patient size, gender, and age.
Landry, Guillaume; Reniers, Brigitte; Granton, Patrick Vincent; van Rooijen, Bart; Beaulieu, Luc; Wildberger, Joachim E; Verhaegen, Frank
2011-09-01
Dual energy CT (DECT) imaging can provide both the electron density ρ(e) and effective atomic number Z(eff), thus facilitating tissue type identification. This paper investigates the accuracy of a dual source DECT scanner by means of measurements and simulations. Previous simulation work suggested improved Monte Carlo dose calculation accuracy when compared to single energy CT for low energy photon brachytherapy, but lacked validation. As such, we aim to validate our DECT simulation model in this work. A cylindrical phantom containing tissue mimicking inserts was scanned with a second generation dual source scanner (SOMATOM Definition FLASH) to obtain Z(eff) and ρ(e). A model of the scanner was designed in ImaSim, a CT simulation program, and was used to simulate the experiment. Accuracy of measured Z(eff) (labelled Z) was found to vary from -10% to 10% from low to high Z tissue substitutes while the accuracy on ρ(e) from DECT was about 2.5%. Our simulation reproduced the experiments within ±5% for both Z and ρ(e). A clinical DECT scanner was able to extract Z and ρ(e) of tissue substitutes. Our simulation tool replicates the experiments within a reasonable accuracy. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
[Evaluation of Organ Dose Estimation from Indices of CT Dose Using Dose Index Registry].
Iriuchijima, Akiko; Fukushima, Yasuhiro; Ogura, Akio
Direct measurement of each patient organ dose from computed tomography (CT) is not possible. Most methods to estimate patient organ dose is using Monte Carlo simulation with dedicated software. However, dedicated software is too expensive for small scale hospitals. Not every hospital can estimate organ dose with dedicated software. The purpose of this study was to evaluate the simple method of organ dose estimation using some common indices of CT dose. The Monte Carlo simulation software Radimetrics (Bayer) was used for calculating organ dose and analysis relationship between indices of CT dose and organ dose. Multidetector CT scanners were compared with those from two manufactures (LightSpeed VCT, GE Healthcare; SOMATOM Definition Flash, Siemens Healthcare). Using stored patient data from Radimetrics, the relationships between indices of CT dose and organ dose were indicated as each formula for estimating organ dose. The accuracy of estimation method of organ dose was compared with the results of Monte Carlo simulation using the Bland-Altman plots. In the results, SSDE was the feasible index for estimation organ dose in almost organs because it reflected each patient size. The differences of organ dose between estimation and simulation were within 23%. In conclusion, our estimation method of organ dose using indices of CT dose is convenient for clinical with accuracy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hofmann, Christian; Sawall, Stefan; Knaup, Michael
2014-06-15
Purpose: Iterative image reconstruction gains more and more interest in clinical routine, as it promises to reduce image noise (and thereby patient dose), to reduce artifacts, or to improve spatial resolution. Among vendors and researchers, however, there is no consensus of how to best achieve these aims. The general approach is to incorporatea priori knowledge into iterative image reconstruction, for example, by adding additional constraints to the cost function, which penalize variations between neighboring voxels. However, this approach to regularization in general poses a resolution noise trade-off because the stronger the regularization, and thus the noise reduction, the stronger themore » loss of spatial resolution and thus loss of anatomical detail. The authors propose a method which tries to improve this trade-off. The proposed reconstruction algorithm is called alpha image reconstruction (AIR). One starts with generating basis images, which emphasize certain desired image properties, like high resolution or low noise. The AIR algorithm reconstructs voxel-specific weighting coefficients that are applied to combine the basis images. By combining the desired properties of each basis image, one can generate an image with lower noise and maintained high contrast resolution thus improving the resolution noise trade-off. Methods: All simulations and reconstructions are performed in native fan-beam geometry. A water phantom with resolution bar patterns and low contrast disks is simulated. A filtered backprojection (FBP) reconstruction with a Ram-Lak kernel is used as a reference reconstruction. The results of AIR are compared against the FBP results and against a penalized weighted least squares reconstruction which uses total variation as regularization. The simulations are based on the geometry of the Siemens Somatom Definition Flash scanner. To quantitatively assess image quality, the authors analyze line profiles through resolution patterns to define a contrast factor for contrast-resolution plots. Furthermore, the authors calculate the contrast-to-noise ratio with the low contrast disks and the authors compare the agreement of the reconstructions with the ground truth by calculating the normalized cross-correlation and the root-mean-square deviation. To evaluate the clinical performance of the proposed method, the authors reconstruct patient data acquired with a Somatom Definition Flash dual source CT scanner (Siemens Healthcare, Forchheim, Germany). Results: The results of the simulation study show that among the compared algorithms AIR achieves the highest resolution and the highest agreement with the ground truth. Compared to the reference FBP reconstruction AIR is able to reduce the relative pixel noise by up to 50% and at the same time achieve a higher resolution by maintaining the edge information from the basis images. These results can be confirmed with the patient data. Conclusions: To evaluate the AIR algorithm simulated and measured patient data of a state-of-the-art clinical CT system were processed. It is shown, that generating CT images through the reconstruction of weighting coefficients has the potential to improve the resolution noise trade-off and thus to improve the dose usage in clinical CT.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Montoya, J; Ferrero, A; Yu, L
Purpose: To investigate the noise and spatial resolution properties of virtual non-contrast (VNC) dual-energy CT images compared to true non-contrast (TNC) images across multiple patient sizes and CT systems. Methods: Torso-shaped water phantoms with lateral widths of 25, 30, 35, 40 and 45 cm and a high resolution bar pattern phantom (Catphan CTP528) were scanned using 2nd and 3rd generation dual-source CT systems (Scanner A: Somatom Definition Flash, Scanner B: Somatom Force, Siemens Healthcare) in dual-energy scan mode with the same radiation dose for a given phantom size. Tube potentials of 80/Sn140 and 100/Sn140 on Scanner A and 80/Sn150, 90/Sn150more » and 100/Sn150 on Scanner B were evaluated to examine the impact of spectral separation. Images were reconstructed using a medium sharp quantitative kernel (Qr40), 1.0-mm thickness, 1.0-mm interval and 20 cm field of view. Mixed images served as TNC images. VNC images were created using commercial software (Virtual Unenhanced, Syngo VIA Version VA30, Siemens Healthcare). The noise power spectrum (NPS), area under the NPS, peak frequency of the NPS and image noise were measured for every phantom size and tube potential combination in TNC and VNC images. Results were compared within and between CT systems. Results: Minimal shift in NPS peak frequencies was observed in VNC images compared to TNC for NPS having pronounced peaks. Image noise and area under the NPS were higher in VNC images compared to TNC images across all tube potentials and for scanner A compared to scanner B. Limiting spatial resolution was deemed to be identical between VNC and TNC images. Conclusion: Quantitative assessment of image quality in VNC images demonstrated higher noise but equivalent spatial resolution compared to TNC images. Decreased noise was observed in the 3rd generation dual-source CT system for tube potential pairs having greater spectral separation. Dr. McCollough receives research support from Siemens Healthcare.« less
Development and comparison of projection and image space 3D nodule insertion techniques
NASA Astrophysics Data System (ADS)
Robins, Marthony; Solomon, Justin; Sahbaee, Pooyan; Samei, Ehsan
2016-04-01
This study aimed to develop and compare two methods of inserting computerized virtual lesions into CT datasets. 24 physical (synthetic) nodules of three sizes and four morphologies were inserted into an anthropomorphic chest phantom (LUNGMAN, KYOTO KAGAKU). The phantom was scanned (Somatom Definition Flash, Siemens Healthcare) with and without nodules present, and images were reconstructed with filtered back projection and iterative reconstruction (SAFIRE) at 0.6 mm slice thickness using a standard thoracic CT protocol at multiple dose settings. Virtual 3D CAD models based on the physical nodules were virtually inserted (accounting for the system MTF) into the nodule-free CT data using two techniques. These techniques include projection-based and image-based insertion. Nodule volumes were estimated using a commercial segmentation tool (iNtuition, TeraRecon, Inc.). Differences were tested using paired t-tests and R2 goodness of fit between the virtually and physically inserted nodules. Both insertion techniques resulted in nodule volumes very similar to the real nodules (<3% difference) and in most cases the differences were not statistically significant. Also, R2 values were all <0.97 for both insertion techniques. These data imply that these techniques can confidently be used as a means of inserting virtual nodules in CT datasets. These techniques can be instrumental in building hybrid CT datasets composed of patient images with virtually inserted nodules.
Single-phase dual-energy CT allows for characterization of renal masses as benign or malignant.
Graser, Anno; Becker, Christoph R; Staehler, Michael; Clevert, Dirk A; Macari, Michael; Arndt, Niko; Nikolaou, Konstantin; Sommer, Wieland; Stief, Christian; Reiser, Maximilian F; Johnson, Thorsten R C
2010-07-01
To evaluate the diagnostic accuracy of dual-energy CT (DECT) in renal mass characterization using a single-phase acquisition. A total of 202 patients (148 males, 54 females; 63 +/- 13 years) with ultrasound-based suspicion of a renal mass underwent unenhanced single energy and nephrographic phase DECT on a dual source scanner (Siemens Somatom Definition Dual Source, n = 174; Somatom Definition Flash, n = 28). Scan parameters for DECT were: tube potential, 80/100 and 100/Sn140 kVp; exposure, 404/300 and 96/232 effective mAs; collimation, 14 x 1.2/32 x 0.6 mm. Two abdominal radiologists assessed DECT and SECT image quality and noise on a 5-point visual analogue scale. Using solely the DE acquisition including virtual nonenhanced (VNE) and color coded iodine images that enable direct visualization of iodine, masses were characterized as benign or malignant. In a second reading session after 34 to 72 (average: 55) days, the same assessment was again performed using both the true nonenhanced (TNE) and nephrographic phase scans thereby simulating conventional single-energy CT. Sensitivities, specificities, diagnostic accuracies, and interpretation times and were recorded for both reading paradigms. Dose reduction of a single-phase over a dual-phase protocol was calculated. Results were tested for statistical significance using the paired Wilcoxon signed rank test and student t test. Differences in sensitivities were tested for significance using the McNemar test. Of the 202 patients, 115 (56.9%) underwent surgical resection of renal masses. Histopathology showed malignancy in 99 and benign tumors in 18 patients, in 48 patients (23.7%), follow-up imaging showed size stability of lesions diagnosed as benign, and 37 patients (18.3%) had no mass. Based on DECT only, 95/99 (96.0%) patients with malignancy and 96/103 (93.2%) patients without malignancy were correctly identified, for an overall accuracy of 94.6%. The dual-phase approach identified 96/99 (97.0%) and 98/103 (95.1%), accuracy 96.0%, P > 0.05 for both. Mean interpretation time was 2.2 +/- 0.8 minutes for DECT, and 3.5 +/- 1.0 minutes for the dual-phase protocol, P < 0.001. Mean VNE/TNE image quality was 1.68 +/- 0.65/1.30 +/- 0.59, noise was 2.03 +/- 0.57/1.18 +/- 0.29, P < 0.001 for both. Omission of the true unenhanced phase lead to a 48.9 +/- 7.0% dose reduction. DECT allows for fast and accurate characterization of renal masses in a single-phase acquisition. Interpretation of color coded images significantly reduces interpretation time. Omission of a nonenhanced acquisition can reduce radiation exposure by almost 50%.
Ketelsen, Dominik; Buchgeister, Markus; Korn, Andreas; Fenchel, Michael; Schmidt, Bernhard; Flohr, Thomas G; Thomas, Christoph; Schabel, Christoph; Tsiflikas, Ilias; Syha, Roland; Claussen, Claus D; Heuschmid, Martin
2012-01-01
Purpose. To estimate effective dose and organ equivalent doses of prospective ECG-triggered high-pitch CTCA. Materials and Methods. For dose measurements, an Alderson-Rando phantom equipped with thermoluminescent dosimeters was used. The effective dose was calculated according to ICRP 103. Exposure was performed on a second-generation dual-source scanner (SOMATOM Definition Flash, Siemens Medical Solutions, Germany). The following scan parameters were used: 320 mAs per rotation, 100 and 120 kV, pitch 3.4 for prospectively ECG-triggered high-pitch CTCA, scan range of 13.5 cm, collimation 64 × 2 × 0.6 mm with z-flying focal spot, gantry rotation time 280 ms, and simulated heart rate of 60 beats per minute. Results. Depending on the applied tube potential, the effective whole-body dose of the cardiac scan ranged from 1.1 mSv to 1.6 mSv and from 1.2 to 1.8 mSv for males and females, respectively. The radiosensitive breast tissue in the range of the primary beam caused an increased female-specific effective dose of 8.6%±0.3% compared to males. Decreasing the tube potential, a significant reduction of the effective dose of 35.8% and 36.0% can be achieved for males and females, respectively (P < 0.001). Conclusion. The radiologist and the CT technician should be aware of this new dose-saving strategy to keep the radiation exposure as low as reasonablly achievable.
Determination of ureter stent appearance on dual-energy computed tomography scan.
Jepperson, Maria A; Thiel, David D; Cernigliaro, Joesph G; Broderick, Gregory A; Parker, Alexander S; Haley, William E
2012-11-01
To examine the dual-energy computed tomography (DECT) properties of 7 commonly used ureteral stents to optimize stent selection for calculi monitored using DECT. The use of DECT to evaluate renal and ureteral calculi has recently increased. Seven stents were individually placed in a fish bowl phantom and imaged using a Siemens Somatom Definition Flash CT scanner. DECT peak tube potentials of 80 and 140 kVp and 100 and 140 kVp were used, reflecting our current dual-energy protocols. These were compared to 31 in vivo stents of known composition. The data were reconstructed on a multimodality WorkPlace (Siemens) using CT syngo Post-Processing Suite software. The average patient age was 64 years (range 27-90). The average body mass index was 31.9 kg/m(2) (range 24-51.6). Of the 27 patients, 4 had uric acid stones and 22 had calcium-based stones; 1 patient had undergone renal transplantation. No difference was seen in the dual-energy characterization of stents from the same manufacturer. All imaged Cook and Bard stents had a dual-energy characterization that approached that of calcium stones (blue). All Boston Scientific and Gyrus ACMI stents had a dual-energy characterization resembling that of uric acid stones (red). The present study evaluated the stent appearance on DECT for various stent manufacturers. This information will aid in the optimal stent selection for patients undergoing treatment of renal calculi and followed up with DECT. Copyright © 2012 Elsevier Inc. All rights reserved.
Code of Federal Regulations, 2013 CFR
2013-07-01
....4000 Definitions. The following definitions apply in this subpart. Combustible liquids. Liquids having... liquids—those having flash points at or above 100 °F (37.8 °C) and below 140 °F (60 °C). Class IIIA liquids—those having flash points at or above 140 °F (60 °C) and below 200 °F (93.4 °C). Class IIIB...
Code of Federal Regulations, 2011 CFR
2011-07-01
....4000 Definitions. The following definitions apply in this subpart. Combustible liquids. Liquids having... liquids—those having flash points at or above 100 °F (37.8 °C) and below 140 °F (60 °C). Class IIIA liquids—those having flash points at or above 140 °F (60 °C) and below 200 °F (93.4 °C). Class IIIB...
Paul, Jijo; Banckwitz, Rosemarie; Krauss, Bernhard; Vogl, Thomas J; Maentele, Werner; Bauer, Ralf W
2012-04-01
To determine effective dose (E) during standard chest CT using an organ dose-based and a dose-length-product-based (DLP) approach for four different scan protocols including high-pitch and dual-energy in a dual-source CT scanner of the second generation. Organ doses were measured with thermo luminescence dosimeters (TLD) in an anthropomorphic male adult phantom. Further, DLP-based dose estimates were performed by using the standard 0.014mSv/mGycm conversion coefficient k. Examinations were performed on a dual-source CT system (Somatom Definition Flash, Siemens). Four scan protocols were investigated: (1) single-source 120kV, (2) single-source 100kV, (3) high-pitch 120kV, and (4) dual-energy with 100/Sn140kV with equivalent CTDIvol and no automated tube current modulation. E was then determined following recommendations of ICRP publication 103 and 60 and specific k values were derived. DLP-based estimates differed by 4.5-16.56% and 5.2-15.8% relatively to ICRP 60 and 103, respectively. The derived k factors calculated from TLD measurements were 0.0148, 0.015, 0.0166, and 0.0148 for protocol 1, 2, 3 and 4, respectively. Effective dose estimations by ICRP 103 and 60 for single-energy and dual-energy protocols show a difference of less than 0.04mSv. Estimates of E based on DLP work equally well for single-energy, high-pitch and dual-energy CT examinations. The tube potential definitely affects effective dose in a substantial way. Effective dose estimations by ICRP 103 and 60 for both single-energy and dual-energy examinations differ not more than 0.04mSv. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Dual energy CT of the chest: how about the dose?
Schenzle, Jan C; Sommer, Wieland H; Neumaier, Klement; Michalski, Gisela; Lechel, Ursula; Nikolaou, Konstantin; Becker, Christoph R; Reiser, Maximilian F; Johnson, Thorsten R C
2010-06-01
New generation Dual Source computed tomography (CT) scanners offer different x-ray spectra for Dual Energy imaging. Yet, an objective, manufacturer independent verification of the dose required for the different spectral combinations is lacking. The aim of this study was to assess dose and image noise of 2 different Dual Energy CT settings with reference to a standard chest scan and to compare image noise and contrast to noise ratios (CNR). Also, exact effective dose length products (E/DLP) conversion factors were to be established based on the objectively measured dose. An anthropomorphic Alderson phantom was assembled with thermoluminescent detectors (TLD) and its chest was scanned on a Dual Source CT (Siemens Somatom Definition) in dual energy mode at 140 and 80 kVp with 14 x 1.2 mm collimation. The same was performed on another Dual Source CT (Siemens Somatom Definition Flash) at 140 kVp with 0.8 mm tin filter (Sn) and 100 kVp at 128 x 0.6 mm collimation. Reference scans were obtained at 120 kVp with 64 x 0.6 mm collimation at equivalent CT dose index of 5.4 mGy*cm. Syringes filled with water and 17.5 mg iodine/mL were scanned with the same settings. Dose was calculated from the TLD measurements and the dose length products of the scanner. Image noise was measured in the phantom scans and CNR and spectral contrast were determined in the iodine and water samples. E/DLP conversion factors were calculated as ratio between the measured dose form the TLDs and the dose length product given in the patient protocol. The effective dose measured with TLDs was 2.61, 2.69, and 2.70 mSv, respectively, for the 140/80 kVp, the 140 Sn/100 kVp, and the standard 120 kVp scans. Image noise measured in the average images of the phantom scans was 11.0, 10.7, and 9.9 HU (P > 0.05). The CNR of iodine with optimized image blending was 33.4 at 140/80 kVp, 30.7 at 140Sn/100 kVp and 14.6 at 120 kVp. E/DLP conversion factors were 0.0161 mSv/mGy*cm for the 140/80 kVp protocol, 0.0181 mSv/mGy*cm for the Sn140/100 kVp mode and 0.0180 mSv/mGy*cm for the 120 kVp examination. Dual Energy CT is feasible without additional dose. There is no significant difference in image noise, while CNR can be doubled with optimized dual energy CT reconstructions. A restriction in collimation is required for dose-neutrality at 140/80 kVp, whereas this is not necessary at 140 Sn/100 kVp. Thus, CT can be performed routinely in Dual Energy mode without additional dose or compromises in image quality.
Iriuchijima, Akiko; Fukushima, Yasuhiro; Ogura, Akio
Direct measurement of each patient organ dose from computed tomography (CT) is not possible. Most methods to estimate patient organ dose is using Monte Carlo simulation with dedicated software. However, the method and the relative differences between organ dose simulation and measurement is unclear. The purpose of this study was to compare organ doses evaluated by Monte Carlo simulation with doses evaluated by in-phantom dosimetry. The simulation software Radimetrics (Bayer) was used for the calculation of organ dose. Measurement was performed with radio-photoluminescence glass dosimeter (RPLD) set at various organ positions within RANDO phantom. To evaluate difference of CT scanner, two different CT scanners were used in this study. Angular dependence of RPLD and measurement of effective energy were performed for each scanner. The comparison of simulation and measurement was evaluated by relative differences. In the results, angular dependence of RPLD at two scanners was 31.6±0.45 mGy for SOMATOM Definition Flash and 29.2±0.18 mGy for LightSpeed VCT. The organ dose was 42.2 mGy (range, 29.9-52.7 mGy) by measurements and 37.7 mGy (range, 27.9-48.1 mGy) by simulations. The relative differences of organ dose between measurement and simulation were 13%, excluding of breast's 42%. We found that organ dose by simulation was lower than by measurement. In conclusion, the results of relative differences will be useful for evaluating organ doses for individual patients by simulation software Radimetrics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mahmood, U; Dauer, L; Erdi, Y
Purpose: Our goal was to evaluate low contrast detectability (LCD) for abdominal CT protocols across two CT scanner manufacturers, while producing a similar noise texture and CTDIvol for acquired images. Methods: A CIRS tissue equivalent LCD phantom containing three columns of 7 spherical targets, ranging from 10 mm to 2.4 mm, that are 5, 10, and 20 HU below the background matrix (HUBB) was scanned using two a GE HD750 64 slice scanner and a Siemens Somatom Definition AS 64 slice scanner. Protocols were designed to deliver a CTDIvol of 12.26 mGy and images were reconstructed with FBP, ASIR andmore » Sapphire. Comparisons were made with those algorithms that had matching noise power spectrum peaks (NPS). NPS information was extracted from a previously published article that matched NPS peak frequencies across manufacturers by calculating the NPS from uniform phantom images reconstructed with several IR algorithms. Results: The minimum detectable lesion size in the 20 HUBB and 10 HUBB column was 6.3 mm, and 10 mm in the 5 HUBB column for the GE HD 750 scanner. The minimum detectable lesion size in the 20 HUBB column was 4.8 mm, in the 10 HUBB column, 9.5 mm, and the 5 HUBB column, 10 mm for the Siemens Somatom Definition AS. Conclusion: Reducing radiation dose while improving or maintaining LCD is possible with application of IR. However, there are several different IR algorithms, with each generating a different resolution and noise texture. In multi-manufacturer settings, matching only the CTDIvol between manufacturers may Result in a loss of clinically relevant information.« less
Quantitative imaging of peripheral trabecular bone microarchitecture using MDCT.
Chen, Cheng; Zhang, Xiaoliu; Guo, Junfeng; Jin, Dakai; Letuchy, Elena M; Burns, Trudy L; Levy, Steven M; Hoffman, Eric A; Saha, Punam K
2018-01-01
Osteoporosis associated with reduced bone mineral density (BMD) and microarchitectural changes puts patients at an elevated risk of fracture. Modern multidetector row CT (MDCT) technology, producing high spatial resolution at increasingly lower dose radiation, is emerging as a viable modality for trabecular bone (Tb) imaging. Wide variation in CT scanners raises concerns of data uniformity in multisite and longitudinal studies. A comprehensive cadaveric study was performed to evaluate MDCT-derived Tb microarchitectural measures. A human pilot study was performed comparing continuity of Tb measures estimated from two MDCT scanners with significantly different image resolution features. Micro-CT imaging of cadaveric ankle specimens (n=25) was used to examine the validity of MDCT-derived Tb microarchitectural measures. Repeat scan reproducibility of MDCT-based Tb measures and their ability to predict mechanical properties were examined. To assess multiscanner data continuity of Tb measures, the distal tibias of 20 volunteers (age:26.2±4.5Y,10F) were scanned using the Siemens SOMATOM Definition Flash and the higher resolution Siemens SOMATOM Force scanners with an average 45-day time gap between scans. The correlation of Tb measures derived from the two scanners over 30% and 60% peel regions at the 4% to 8% of distal tibia was analyzed. MDCT-based Tb measures characterizing bone network area density, plate-rod microarchitecture, and transverse trabeculae showed good correlations (r∈0.85,0.92) with the gold standard micro-CT-derived values of matching Tb measures. However, other MDCT-derived Tb measures characterizing trabecular thickness and separation, erosion index, and structure model index produced weak correlation (r<0.8) with their micro-CT-derived values. Most MDCT Tb measures were found repeatable (ICC∈0.94,0.98). The Tb plate-width measure showed a strong correlation (r = 0.89) with experimental yield stress, while the transverse trabecular measure produced the highest correlation (r = 0.81) with Young's modulus. The data continuity experiment showed that, despite significant differences in image resolution between two scanners (10% MTF along xy-plane and z-direction - Flash: 16.2 and 17.9 lp/cm; Force: 24.8 and 21.0 lp/cm), most Tb measures had high Pearson correlations (r > 0.95) between values estimated from the two scanners. Relatively lower correlation coefficients were observed for the bone network area density (r = 0.91) and Tb separation (r = 0.93) measures. Most MDCT-derived Tb microarchitectural measures are reproducible and their values derived from two scanners strongly correlate with each other as well as with bone strength. This study has highlighted those MDCT-derived measures which show the greatest promise for characterization of bone network area density, plate-rod and transverse trabecular distributions with a good correlation (r ≥ 0.85) compared with their micro-CT-derived values. At the same time, other measures representing trabecular thickness and separation, erosion index, and structure model index produced weak correlations (r < 0.8) with their micro-CT-derived values, failing to accurately portray the projected trabecular microarchitectural features. Strong correlations of Tb measures estimated from two scanners suggest that image data from different scanners can be used successfully in multisite and longitudinal studies with linear calibration required for some measures. In summary, modern MDCT scanners are suitable for effective quantitative imaging of peripheral Tb microarchitecture if care is taken to focus on appropriate quantitative metrics. © 2017 American Association of Physicists in Medicine.
Pediatric chest and abdominopelvic CT: organ dose estimation based on 42 patient models.
Tian, Xiaoyu; Li, Xiang; Segars, W Paul; Paulson, Erik K; Frush, Donald P; Samei, Ehsan
2014-02-01
To estimate organ dose from pediatric chest and abdominopelvic computed tomography (CT) examinations and evaluate the dependency of organ dose coefficients on patient size and CT scanner models. The institutional review board approved this HIPAA-compliant study and did not require informed patient consent. A validated Monte Carlo program was used to perform simulations in 42 pediatric patient models (age range, 0-16 years; weight range, 2-80 kg; 24 boys, 18 girls). Multidetector CT scanners were modeled on those from two commercial manufacturers (LightSpeed VCT, GE Healthcare, Waukesha, Wis; SOMATOM Definition Flash, Siemens Healthcare, Forchheim, Germany). Organ doses were estimated for each patient model for routine chest and abdominopelvic examinations and were normalized by volume CT dose index (CTDI(vol)). The relationships between CTDI(vol)-normalized organ dose coefficients and average patient diameters were evaluated across scanner models. For organs within the image coverage, CTDI(vol)-normalized organ dose coefficients largely showed a strong exponential relationship with the average patient diameter (R(2) > 0.9). The average percentage differences between the two scanner models were generally within 10%. For distributed organs and organs on the periphery of or outside the image coverage, the differences were generally larger (average, 3%-32%) mainly because of the effect of overranging. It is feasible to estimate patient-specific organ dose for a given examination with the knowledge of patient size and the CTDI(vol). These CTDI(vol)-normalized organ dose coefficients enable one to readily estimate patient-specific organ dose for pediatric patients in clinical settings. This dose information, and, as appropriate, attendant risk estimations, can provide more substantive information for the individual patient for both clinical and research applications and can yield more expansive information on dose profiles across patient populations within a practice. © RSNA, 2013.
van der Zant, Friso M; Wondergem, Maurits; Lazarenko, Sergiy V; Geenen, Remy W F; Umans, Victor A; Cornel, Jan-Hein; Knol, Remco J J
2015-07-01
To assess the presence of coronary artery disease (CAD) in women with atypical chest pain with low or intermediate risk for significant CAD by means of calcium scoring (CaSc) combined with coronary computed tomography angiography (CCTA) and to estimate the equivalent radiation dose in women. From December 2011 until July 2013, all consecutively performed cardiac CTs in women with atypical chest pain were included prospectively in the present study. Both CaSc and CCTA were obtained by a dual source flying focal spot 2×64 slice Somatom Definition Flash. Absence of CAD was defined as CaSc 0 and absence of noncalcified plaques. Presence of CAD was determined as CaSc>0 and/or presence of noncalcified plaques. The impact on patient management was also scored within our patient cohort. A total of 1033 procedures in 1014 women (mean age 59±10 years; mean BMI 26±8) were analyzed. In 520 (51%) women, CAD was absent. In 494 (49%) women, CAD was diagnosed, and in this subgroup the mean CaSc was 137±229. Thirty-seven (7%) of 494 women with CAD showed only noncalcified plaques. The mean equivalent radiation dose for the cardiac CTs of 1014 women was 2.2±1.6 mSv. Combined CaSc and CCTA excludes CAD in approximately 50% of women with atypical chest pain, and delivers a modest radiation dose of 2.2±1.6 mSv. CCTA has a substantial impact on patient management and can thus be advocated as first diagnostic tool in excluding CAD in women with atypical chest pain in terms of latest generation equipment with emphasize on radiation reduction techniques.
Gariani, Joanna; Martin, Steve P; Botsikas, Diomidis; Becker, Christoph D; Montet, Xavier
2018-06-14
To compare radiation dose and image quality of thoracoabdominal scans obtained with a high-pitch protocol (pitch 3.2) and iterative reconstruction (Sinogram Affirmed Iterative Reconstruction) in comparison to standard pitch reconstructed with filtered back projection (FBP) using dual source CT. 114 CT scans (Somatom Definition Flash, Siemens Healthineers, Erlangen, Germany), 39 thoracic scans, 54 thoracoabdominal scans and 21 abdominal scans were performed. Analysis of three protocols was undertaken; pitch of 1 reconstructed with FBP, pitch of 3.2 reconstructed with SAFIRE, pitch of 3.2 with stellar detectors reconstructed with SAFIRE. Objective and subjective image analysis were performed. Dose differences of the protocols used were compared. Dose was reduced when comparing scans with a pitch of 1 reconstructed with FBP to high-pitch scans with a pitch of 3.2 reconstructed with SAFIRE with a reduction of volume CT dose index of 75% for thoracic scans, 64% for thoracoabdominal scans and 67% for abdominal scans. There was a further reduction after the implementation of stellar detectors reflected in a reduction of 36% of the dose-length product for thoracic scans. This was not at the detriment of image quality, contrast-to-noise ratio, signal-to-noise ratio and the qualitative image analysis revealed a superior image quality in the high-pitch protocols. The combination of a high pitch protocol with iterative reconstruction allows significant dose reduction in routine chest and abdominal scans whilst maintaining or improving diagnostic image quality, with a further reduction in thoracic scans with stellar detectors. Advances in knowledge: High pitch imaging with iterative reconstruction is a tool that can be used to reduce dose without sacrificing image quality.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baer, E; Jee, K; Zhang, R
Purpose: To evaluate the clinical performance of dual-energy CT (DECT) in determining proton stopping power ratios (SPR) and demonstrate advantages over conventional single-energy CT (SECT). Methods: SECT and DECT scans of tissue-equivalent plastics as well as animal meat samples are performed with a Siemens SOMATOM Definition Flash. The methods of Schneider et al. (1996) and Bourque et al. (2014) are used to determine proton SPR on SECT and DECT images, respectively. Waterequivalent path length (WEPL) measurements of plastics and tissue samples are performed with a 195 MeV proton beam. WEPL values are determined experimentally using the depth-dose shift and dosemore » extinction methods. Results: Comparison between CT-based and experimental WEPL is performed for 12 tissue-equivalent plastic as well as 6 meat boxes containing animal liver, kidney, heart, stomach, muscle and bones. For plastic materials, results show a systematic improvement in determining SPR with DECT, with a mean absolute error of 0.4% compared to 1.7% for SECT. For the meat samples, preliminary results show the ability for DECT to determine WEPL with a mean absolute value of 1.1% over all meat boxes. Conclusion: This work demonstrates the potential in using DECT for determining proton SPR with plastic materials in a clinical context. Further work is required to show the benefits of DECT for tissue samples. While experimental uncertainties could be a limiting factor to show the benefits of DECT over SECT for the meat samples, further work is required to adapt the DECT formalism in the context of clinical use, where noise and artifacts play an important role.« less
Beeres, Martin; Bauer, Ralf W; Kerl, Josef M; Vogl, Thomas J; Lee, Clara
2015-01-01
Objectives: The aim of our study was to find out how much energy is applicable in second-generation dual source high-pitch computed tomography (CT) in imaging of the abdomen. Materials and Methods: We examined an upper abdominal phantom using a Somatom Definition Flash CT-Scanner (Siemens, Forchheim, Germany). The study protocol consisted of a scan-series at 100 kV and 120 kV. In each scan series we started with a pitch of 3.2 and reduced it in steps of 0.2, until a pitch of 1.6 was reached. The current was adjusted to the maximum the scanner could achieve. Energy values, image noise, image quality, and radiation exposure were evaluated. Results: For a pitch of 3.2 the maximum applicable current was 142 mAs at 120 kV and in 100 kV the maximum applicable current was 114 mAs. For conventional abdominal imaging, current levels of 200 to 260 mAs are generally used. To achieve similar current levels, we had to decrease the pitch to 1.8 at 100 kV — at this pitch we could perform our imaging at 204 mAs. At a pitch of 2.2 in 120 kV we could apply a current of 206 mAs. Conclusion: We conclude our study by stating that if there is a need for a higher current, we have to reduce the pitch. In a high-pitch dual source CT, we always have to remember where our main focus is, so we can adjust the pitch to the energy we need in the area of the body that has to be imaged, to find answers to the clinical question being raised. PMID:25806137
49 CFR 173.120 - Class 3-Definitions.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Materials Other Than Class 1 and Class 7 § 173.120 Class 3—Definitions. (a) Flammable liquid. For the purpose of this subchapter, a flammable liquid (Class 3) means a liquid having a flash point of not more...) and below 93 °C (200 °F). (2) A flammable liquid with a flash point at or above 38 °C (100 °F) that...
49 CFR 173.120 - Class 3-Definitions.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Materials Other Than Class 1 and Class 7 § 173.120 Class 3—Definitions. (a) Flammable liquid. For the purpose of this subchapter, a flammable liquid (Class 3) means a liquid having a flash point of not more...) and below 93 °C (200 °F). (2) A flammable liquid with a flash point at or above 38 °C (100 °F) that...
49 CFR 173.120 - Class 3-Definitions.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Materials Other Than Class 1 and Class 7 § 173.120 Class 3—Definitions. (a) Flammable liquid. For the purpose of this subchapter, a flammable liquid (Class 3) means a liquid having a flash point of not more...) and below 93 °C (200 °F). (2) A flammable liquid with a flash point at or above 38 °C (100 °F) that...
49 CFR 173.120 - Class 3-Definitions.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Materials Other Than Class 1 and Class 7 § 173.120 Class 3—Definitions. (a) Flammable liquid. For the purpose of this subchapter, a flammable liquid (Class 3) means a liquid having a flash point of not more...) and below 93 °C (200 °F). (2) A flammable liquid with a flash point at or above 38 °C (100 °F) that...
Kim, Se Hyung; Lee, Jeong Min; Kim, Young Jun; Lee, Jae Young; Han, Joon Koo; Choi, Byung Ihn
2008-10-01
The purpose of this study was to introduce a new high-definition flow (HDF) Doppler technique and to compare its performance with those of color Doppler ultrasonography (CDU) and power Doppler ultrasonography (PDU) for assessment of hepatic vasculature in native and transplanted livers. High-definition flow was invented as a high-resolution bidirectional PDU technique. We obtained CDU, PDU, and HDF images of the hepatic artery (HA), portal vein (PV), and hepatic vein from 60 patients. They were divided into 2 groups: a liver transplantation group (group 1, n = 10) and a native liver group (group 2, n = 50). Two radiologists independently reviewed the cine images and graded them using a 4-point scale in terms of the clarity of the vessel margin and degree of depiction of the HA, flow filling, and flash artifacts. The degree of differentiation between the HA and PV was also evaluated. Flow directionality was recorded, and interobserver agreement was finally analyzed. Moderate to almost perfect agreement was achieved between radiologists for all parameters of each ultrasonographic technique. High-definition flow was significantly superior to both CDU and PDU with respect to all analyzed items except the degree of flash artifacts (P < .05). With regard to flash artifacts, CDU was significantly better than either PDU or HDF. High-definition flow provided directional information, as did CDU. The HDF technique provides better resolution for depicting hepatic vessels as well as their margins with less blooming compared with conventional Doppler ultrasonography in both native and transplanted liver. It also provides solid directional flow information. One point of concern, however, is the frequency of flash artifacts compared with that on CDU.
CT breast dose reduction with the use of breast positioning and organ-based tube current modulation.
Fu, Wanyi; Tian, Xiaoyu; Sturgeon, Gregory M; Agasthya, Greeshma; Segars, William Paul; Goodsitt, Mitchell M; Kazerooni, Ella A; Samei, Ehsan
2017-02-01
This study aimed to investigate the breast dose reduction potential of a breast-positioning (BP) technique for thoracic CT examinations with organ-based tube current modulation (OTCM). This study included 13 female anthropomorphic computational phantoms (XCAT, age range: 27-65 y.o., weight range: 52-105.8 kg). Each phantom was modified to simulate three breast sizes in standard supine geometry. The modeled breasts were then morphed to emulate BP that constrained the majority of the breast tissue inside the 120° anterior tube current (mA) reduction zone. The OTCM mA value was modeled using a ray-tracing program, which reduced the mA to 20% in the anterior region with a corresponding increase to the posterior region. The organ doses were estimated by a validated Monte Carlo program for a typical clinical CT system (SOMATOM Definition Flash, Siemens Healthcare). The simulated organ doses and organ doses normalized by CTDI vol were used to compare three CT protocols: attenuation-based tube current modulation (ATCM), OTCM, and OTCM with BP (OTCM BP ). On average, compared to ATCM, OTCM reduced breast dose by 19.3 ± 4.5%, whereas OTCM BP reduced breast dose by 38.6 ± 8.1% (an additional 23.8 ± 9.4%). The dose saving of OTCM BP was more significant for larger breasts (on average 33, 38, and 44% reduction for 0.5, 1, and 2 kg breasts, respectively). Compared to ATCM, OTCM BP also reduced thymus and heart dose by 15.1 ± 7.4% and 15.9 ± 6.2% respectively. In thoracic CT examinations, OTCM with a breast-positioning technique can markedly reduce unnecessary exposure to radiosensitive organs in anterior chest wall, specifically breast tissue. The breast dose reduction is more notable for women with larger breasts. © 2016 American Association of Physicists in Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sorensen, J; Duran, C; Stingo, F
Purpose: To characterize the effect of virtual monochromatic reconstructions on several commonly used texture analysis features in DECT of the chest. Further, to assess the effect of monochromatic energy levels on the ability of these textural features to identify tissue types. Methods: 20 consecutive patients underwent chest CTs for evaluation of lung nodules using Siemens Somatom Definition Flash DECT. Virtual monochromatic images were constructed at 10keV intervals from 40–190keV. For each patient, an ROI delineated the lesion under investigation, and cylindrical ROI’s were placed within 5 different healthy tissues (blood, fat, muscle, lung, and liver). Several histogram- and Grey Levelmore » Cooccurrence Matrix (GLCM)-based texture features were then evaluated in each ROI at each energy level. As a means of validation, these feature values were then used in a random forest classifier to attempt to identify the tissue types present within each ROI. Their predictive accuracy at each energy level was recorded. Results: All textural features changed considerably with virtual monochromatic energy, particularly below 70keV. Most features exhibited a global minimum or maximum around 80keV, and while feature values changed with energy above this, patient ranking was generally unaffected. As expected, blood demonstrated the lowest inter-patient variability, for all features, while lung lesions (encompassing many different pathologies) exhibited the highest. The accuracy of these features in identifying tissues (76% accuracy) was highest at 80keV, but no clear relationship between energy and classification accuracy was found. Two common misclassifications (blood vs liver and muscle vs fat) accounted for the majority (24 of the 28) errors observed. Conclusion: All textural features were highly dependent on virtual monochromatic energy level, especially below 80keV, and were more stable above this energy. However, in a random forest model, these commonly used features were able to reliably differentiate between most tissues types regardless of energy level. Dr Godoy has received a dual-energy CT research grant from Siemens Healthcare. That grant did not directly fund this research.« less
Pediatric Chest and Abdominopelvic CT: Organ Dose Estimation Based on 42 Patient Models
Tian, Xiaoyu; Li, Xiang; Segars, W. Paul; Paulson, Erik K.; Frush, Donald P.
2014-01-01
Purpose To estimate organ dose from pediatric chest and abdominopelvic computed tomography (CT) examinations and evaluate the dependency of organ dose coefficients on patient size and CT scanner models. Materials and Methods The institutional review board approved this HIPAA–compliant study and did not require informed patient consent. A validated Monte Carlo program was used to perform simulations in 42 pediatric patient models (age range, 0–16 years; weight range, 2–80 kg; 24 boys, 18 girls). Multidetector CT scanners were modeled on those from two commercial manufacturers (LightSpeed VCT, GE Healthcare, Waukesha, Wis; SOMATOM Definition Flash, Siemens Healthcare, Forchheim, Germany). Organ doses were estimated for each patient model for routine chest and abdominopelvic examinations and were normalized by volume CT dose index (CTDIvol). The relationships between CTDIvol-normalized organ dose coefficients and average patient diameters were evaluated across scanner models. Results For organs within the image coverage, CTDIvol-normalized organ dose coefficients largely showed a strong exponential relationship with the average patient diameter (R2 > 0.9). The average percentage differences between the two scanner models were generally within 10%. For distributed organs and organs on the periphery of or outside the image coverage, the differences were generally larger (average, 3%–32%) mainly because of the effect of overranging. Conclusion It is feasible to estimate patient-specific organ dose for a given examination with the knowledge of patient size and the CTDIvol. These CTDIvol-normalized organ dose coefficients enable one to readily estimate patient-specific organ dose for pediatric patients in clinical settings. This dose information, and, as appropriate, attendant risk estimations, can provide more substantive information for the individual patient for both clinical and research applications and can yield more expansive information on dose profiles across patient populations within a practice. © RSNA, 2013 PMID:24126364
NASA Astrophysics Data System (ADS)
Xu, Jingyan; Fuld, Matthew K.; Fung, George S. K.; Tsui, Benjamin M. W.
2015-04-01
Iterative reconstruction (IR) methods for x-ray CT is a promising approach to improve image quality or reduce radiation dose to patients. The goal of this work was to use task based image quality measures and the channelized Hotelling observer (CHO) to evaluate both analytic and IR methods for clinical x-ray CT applications. We performed realistic computer simulations at five radiation dose levels, from a clinical reference low dose D0 to 25% D0. A fixed size and contrast lesion was inserted at different locations into the liver of the XCAT phantom to simulate a weak signal. The simulated data were reconstructed on a commercial CT scanner (SOMATOM Definition Flash; Siemens, Forchheim, Germany) using the vendor-provided analytic (WFBP) and IR (SAFIRE) methods. The reconstructed images were analyzed by CHOs with both rotationally symmetric (RS) and rotationally oriented (RO) channels, and with different numbers of lesion locations (5, 10, and 20) in a signal known exactly (SKE), background known exactly but variable (BKEV) detection task. The area under the receiver operating characteristic curve (AUC) was used as a summary measure to compare the IR and analytic methods; the AUC was also used as the equal performance criterion to derive the potential dose reduction factor of IR. In general, there was a good agreement in the relative AUC values of different reconstruction methods using CHOs with RS and RO channels, although the CHO with RO channels achieved higher AUCs than RS channels. The improvement of IR over analytic methods depends on the dose level. The reference dose level D0 was based on a clinical low dose protocol, lower than the standard dose due to the use of IR methods. At 75% D0, the performance improvement was statistically significant (p < 0.05). The potential dose reduction factor also depended on the detection task. For the SKE/BKEV task involving 10 lesion locations, a dose reduction of at least 25% from D0 was achieved.
Aykut, Aktas; Bumin, Degirmenci; Omer, Yilmaz; Mustafa, Kayan; Meltem, Cetin; Orhan, Celik; Nisa, Unlu; Hikmet, Orhan; Hakan, Demirtas; Mert, Koroglu
2015-09-01
The aim was to compare coronary high-definition CT (HDCT) with standard-definition CT (SDCT) angiography as to radiation dose, image quality and accuracy. 28 patients with history of coronary artery disease scanned by HDCT (Discovery CT750 HD) and SDCT (Somatom Definition AS). The scan modes were both axial prospective ECG-triggered. The vessel diameters and vessel attenuation values of totally 280 measurements from 140 coronary arteries were analyzed by two experienced radiologists. All data was analyzed by intraclass correlation test. Image quality graded by motion and stair step artifacts (grade 1, poor, to grade 4, excellent), accuracy of vessel inner and outer diameters were compared between the two CT units using the independent samples t-test and Mann-Whitney U test. The intraclass correlation coefficient (ICC) of measured vessel attenuation values in SDCT between the two radiologists was exceedingly good. The ICC was higher in HDCT. The radiation dose of HDCT was higher than that of SDCT. The mean tube current was 180 (mA) in HDCT and 147(mA) in SDCT with the same tube voltage (kVp). There was no significant difference between image quality. HDCT has a higher radiation dose but has much more atenuation and the spatial resolution which improve measurement accuracy for imaging coronary arteries.
49 CFR 173.120 - Class 3-Definitions.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Closed Cup Tester, (ASTM D 56) (IBR; see § 171.7 of this subchapter); (B) Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus, (ASTM D 3278) (IBR; see § 171.7 of this subchapter... for Flash Point by Pensky-Martens Closed Cup Tester, (ASTM D 93) (IBR; see § 171.7 of this subchapter...
Pilot evaluation of hypnosis for the treatment of hot flashes in breast cancer survivors.
Elkins, Gary; Marcus, Joel; Stearns, Vered; Hasan Rajab, M
2007-05-01
This single arm, pilot study investigated the use of hypnosis to reduce hot flashes in 16 breast cancer survivors. Each patient provided baseline data and received 4 weekly sessions of hypnosis that followed a standardized transcript. Patients were also instructed in self-hypnosis. Throughout the clinical care, patients completed daily diaries of the frequency and severity of their hot flashes. Patients also completed baseline and post-treatment ratings of the degree to which hot flashes interfered with daily activities and quality of life. Results indicated a 59% decrease in total daily hot flashes and a 70% decrease in weekly hot flash scores from their baselines. There was also a significant decrease in the degree to which hot flashes interfered with daily activities for all measures including work, social activities, leisure activities, sleep, mood, concentration, relations with others, sexuality, enjoyment of life, and overall quality of life. This pilot study suggests that clinical hypnosis may be an effective non-hormonal and non-pharmacological treatment for hot flashes. A randomized, controlled clinical trial is planned to more definitively elucidate the efficacy and applicability of hypnosis for reducing hot flashes.
Special technical services for investigation of light flash phenomena
NASA Technical Reports Server (NTRS)
1973-01-01
Details are presented of an investigation aimed at an explanation of the phenomenon of light flashes observed by Apollo crew members. The various theories considered include: penetration of the eye by cosmic particles resulting in retinal stimulation; production of phosphenes or sensations of light through ionization or excitation; appearance of heavily ionized single tracks misinterpreted as light flashes; Cerenkov radiation; and direct excitation of neural tissue by penetrating cosmic rays. It is concluded that the latter two theories are the likeliest mechanisms for the development of a definitive explanation.
Objective performance assessment of five computed tomography iterative reconstruction algorithms.
Omotayo, Azeez; Elbakri, Idris
2016-11-22
Iterative algorithms are gaining clinical acceptance in CT. We performed objective phantom-based image quality evaluation of five commercial iterative reconstruction algorithms available on four different multi-detector CT (MDCT) scanners at different dose levels as well as the conventional filtered back-projection (FBP) reconstruction. Using the Catphan500 phantom, we evaluated image noise, contrast-to-noise ratio (CNR), modulation transfer function (MTF) and noise-power spectrum (NPS). The algorithms were evaluated over a CTDIvol range of 0.75-18.7 mGy on four major MDCT scanners: GE DiscoveryCT750HD (algorithms: ASIR™ and VEO™); Siemens Somatom Definition AS+ (algorithm: SAFIRE™); Toshiba Aquilion64 (algorithm: AIDR3D™); and Philips Ingenuity iCT256 (algorithm: iDose4™). Images were reconstructed using FBP and the respective iterative algorithms on the four scanners. Use of iterative algorithms decreased image noise and increased CNR, relative to FBP. In the dose range of 1.3-1.5 mGy, noise reduction using iterative algorithms was in the range of 11%-51% on GE DiscoveryCT750HD, 10%-52% on Siemens Somatom Definition AS+, 49%-62% on Toshiba Aquilion64, and 13%-44% on Philips Ingenuity iCT256. The corresponding CNR increase was in the range 11%-105% on GE, 11%-106% on Siemens, 85%-145% on Toshiba and 13%-77% on Philips respectively. Most algorithms did not affect the MTF, except for VEO™ which produced an increase in the limiting resolution of up to 30%. A shift in the peak of the NPS curve towards lower frequencies and a decrease in NPS amplitude were obtained with all iterative algorithms. VEO™ required long reconstruction times, while all other algorithms produced reconstructions in real time. Compared to FBP, iterative algorithms reduced image noise and increased CNR. The iterative algorithms available on different scanners achieved different levels of noise reduction and CNR increase while spatial resolution improvements were obtained only with VEO™. This study is useful in that it provides performance assessment of the iterative algorithms available from several mainstream CT manufacturers.
NASA Astrophysics Data System (ADS)
Yuan, X.; Wang, L.; Zhang, M.
2017-12-01
Rainfall deficit in the crop growing seasons is usually accompanied by heat waves. Abnormally high temperature increases evapotranspiration and decreases soil moisture rapidly, and ultimately results in a type of drought with a rapid onset, short duration but devastating impact, which is called "Flash drought". With the increase in global temperature, flash drought is expected to occur more frequently. However, there is no consensus on the definition of flash drought so far. Moreover, large uncertainty exists in the estimation of the flash drought and its trend, and the underlying mechanism for its long-term change is not clear. In this presentation, a parametric multivariate drought index that characterizes the joint probability distribution of key variables of flash drought will be developed, and the historical changes in flash drought over China will be analyzed. In addition, a set of land surface model simulations driven by IPCC CMIP5 models with different forcings and future scenarios, will be used for the detection and attribution of flash drought change. This study is targeted at quantifying the influences of natural and anthropogenic climate change on the flash drought change, projecting its future change as well as the corresponding uncertainty, and improving our understanding of the variation of flash drought and its underlying mechanism in a changing climate.
NASA Astrophysics Data System (ADS)
Jansen, Jan T. M.; Shrimpton, Paul C.
2016-07-01
The ImPACT (imaging performance assessment of CT scanners) CT patient dosimetry calculator is still used world-wide to estimate organ and effective doses (E) for computed tomography (CT) examinations, although the tool is based on Monte Carlo calculations reflecting practice in the early 1990’s. Subsequent developments in CT scanners, definitions of E, anthropomorphic phantoms, computers and radiation transport codes, have all fuelled an urgent need for updated organ dose conversion factors for contemporary CT. A new system for such simulations has been developed and satisfactorily tested. Benchmark comparisons of normalised organ doses presently derived for three old scanners (General Electric 9800, Philips Tomoscan LX and Siemens Somatom DRH) are within 5% of published values. Moreover, calculated normalised values of CT Dose Index for these scanners are in reasonable agreement (within measurement and computational uncertainties of ±6% and ±1%, respectively) with reported standard measurements. Organ dose coefficients calculated for a contemporary CT scanner (Siemens Somatom Sensation 16) demonstrate potential deviations by up to around 30% from the surrogate values presently assumed (through a scanner matching process) when using the ImPACT CT Dosimetry tool for newer scanners. Also, illustrative estimates of E for some typical examinations and a range of anthropomorphic phantoms demonstrate the significant differences (by some 10’s of percent) that can arise when changing from the previously adopted stylised mathematical phantom to the voxel phantoms presently recommended by the International Commission on Radiological Protection (ICRP), and when following the 2007 ICRP recommendations (updated from 1990) concerning tissue weighting factors. Further simulations with the validated dosimetry system will provide updated series of dose coefficients for a wide range of contemporary scanners.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ohno, T; Araki, F
2015-06-15
Purpose: To compare dosimetric properties and patient organ doses from four commercial multidetector CT (MDCT) using Monte Carlo (MC) simulation based on the absorbed dose measured using a Farmer chamber and cylindrical water phantoms according to AAPM TG-111. Methods: Four commercial MDCT were modeled using the GMctdospp (IMPS, Germany) based on the EGSnrc user code. The incident photon spectrum and bowtie filter for MC simulations were determined so that calculated values of aluminum half-value layer (Al-HVL) and off-center ratio (OCR) profile in air agreed with measured values. The MC dose was calibrated from absorbed dose measurements using a Farmer chambermore » and cylindrical water phantoms. The dose distributions of head, chest, and abdominal scan were calculated using patient CT images and mean organ doses were evaluated from dose volume histograms. Results: The HVLs at 120 kVp of Brilliance, LightSpeed, Aquilion, and SOMATOM were 9.1, 7.5, 7.2, and 8.7 mm, respectively. The calculated Al-HVLs agreed with measurements within 0.3%. The calculated and measured OCR profiles agreed within 5%. For adult head scans, mean doses for eye lens from Brilliance, LightSpeed, Aquilion, and SOMATOM were 21.7, 38.5, 47.2 and 28.4 mGy, respectively. For chest scans, mean doses for lung from Brilliance, LightSpeed, Aquilion, and SOMATOM were 21.1, 26.1, 35.3 and 24.0 mGy, respectively. For adult abdominal scans, the mean doses for liver from Brilliance, LightSpeed, Aquilion, and SOMATOM were 16.5, 21.3, 22.7, and 18.0 mGy, respectively. The absorbed doses increased with decreasing Al-HVL. The organ doses from Aquilion were two greater than those from Brilliance in head scan. Conclusion: MC dose distributions based on absorbed dose measurement in cylindrical water phantom are useful to evaluate individual patient organ doses.« less
A first look at global flash drought: long term change and short term predictability
NASA Astrophysics Data System (ADS)
Yuan, Xing; Wang, Linying; Ji, Peng
2017-04-01
"Flash drought" became popular after the unexpected 2012 central USA drought, mainly due to its rapid development, low predictability and devastating impacts on water resources and crop yields. A pilot study by Mo and Lettenmaier (2015) found that flash drought, based on a definition of concurrent heat extreme, soil moisture deficit and evapotranspiration (ET) enhancement at pentad scale, were in decline over USA during recent 100 years. Meanwhile, a recent work indicated that the occurrence of flash drought in China was doubled during the past 30 years, where a severe flash drought in the summer of 2013 ravaged 13 provinces in southern China. As global warming increases the frequency of heat waves and accelerates the hydrological cycle, the flash drought is expected to increase in general, but its trend might also be affected by interannual to decadal climate oscillations. To consolidate the hotspots of flash drought and the effects of climate change on flash drought, a global inventory is being conducted by using multi-source observations (in-situ, satellite and reanalysis), CMIP5 historical simulations and future projections under different forcing scenarios, as well as global land surface hydrological modeling for key variables including surface air temperature, soil moisture and ET. In particular, a global picture of the flash drought distribution, the contribution of naturalized and anthropogenic forcings to global flash drought change, and the risk of global flash drought in the future, will be presented. Besides investigating the long-term change of flash drought, providing reliable early warning is also essential to developing adaptation strategies. While regional drought early warning systems have been emerging in recent decade, forecasting of flash drought is still at an exploratory stage due to limited understanding of flash drought predictability. Here, a set of sub-seasonal to seasonal (S2S) hindcast datasets are being used to assess the short term predictability of flash drought via a perfect model assumption.
Measuring and Estimating Normalized Contrast in Infrared Flash Thermography
NASA Technical Reports Server (NTRS)
Koshti, Ajay M.
2013-01-01
Infrared flash thermography (IRFT) is used to detect void-like flaws in a test object. The IRFT technique involves heating up the part surface using a flash of flash lamps. The post-flash evolution of the part surface temperature is sensed by an IR camera in terms of pixel intensity of image pixels. The IR technique involves recording of the IR video image data and analysis of the data using the normalized pixel intensity and temperature contrast analysis method for characterization of void-like flaws for depth and width. This work introduces a new definition of the normalized IR pixel intensity contrast and normalized surface temperature contrast. A procedure is provided to compute the pixel intensity contrast from the camera pixel intensity evolution data. The pixel intensity contrast and the corresponding surface temperature contrast differ but are related. This work provides a method to estimate the temperature evolution and the normalized temperature contrast from the measured pixel intensity evolution data and some additional measurements during data acquisition.
Dose coefficients in pediatric and adult abdominopelvic CT based on 100 patient models.
Tian, Xiaoyu; Li, Xiang; Segars, W Paul; Frush, Donald P; Paulson, Erik K; Samei, Ehsan
2013-12-21
Recent studies have shown the feasibility of estimating patient dose from a CT exam using CTDI(vol)-normalized-organ dose (denoted as h), DLP-normalized-effective dose (denoted as k), and DLP-normalized-risk index (denoted as q). However, previous studies were limited to a small number of phantom models. The purpose of this work was to provide dose coefficients (h, k, and q) across a large number of computational models covering a broad range of patient anatomy, age, size percentile, and gender. The study consisted of 100 patient computer models (age range, 0 to 78 y.o.; weight range, 2-180 kg) including 42 pediatric models (age range, 0 to 16 y.o.; weight range, 2-80 kg) and 58 adult models (age range, 18 to 78 y.o.; weight range, 57-180 kg). Multi-detector array CT scanners from two commercial manufacturers (LightSpeed VCT, GE Healthcare; SOMATOM Definition Flash, Siemens Healthcare) were included. A previously-validated Monte Carlo program was used to simulate organ dose for each patient model and each scanner, from which h, k, and q were derived. The relationships between h, k, and q and patient characteristics (size, age, and gender) were ascertained. The differences in conversion coefficients across the scanners were further characterized. CTDI(vol)-normalized-organ dose (h) showed an exponential decrease with increasing patient size. For organs within the image coverage, the average differences of h across scanners were less than 15%. That value increased to 29% for organs on the periphery or outside the image coverage, and to 8% for distributed organs, respectively. The DLP-normalized-effective dose (k) decreased exponentially with increasing patient size. For a given gender, the DLP-normalized-risk index (q) showed an exponential decrease with both increasing patient size and patient age. The average differences in k and q across scanners were 8% and 10%, respectively. This study demonstrated that the knowledge of patient information and CTDIvol/DLP values may be used to estimate organ dose, effective dose, and risk index in abdominopelvic CT based on the coefficients derived from a large population of pediatric and adult patients.
Quantitative comparison of noise texture across CT scanners from different manufacturers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Solomon, Justin B.; Christianson, Olav; Samei, Ehsan
2012-10-15
Purpose: To quantitatively compare noise texture across computed tomography (CT) scanners from different manufacturers using the noise power spectrum (NPS). Methods: The American College of Radiology CT accreditation phantom (Gammex 464, Gammex, Inc., Middleton, WI) was imaged on two scanners: Discovery CT 750HD (GE Healthcare, Waukesha, WI), and SOMATOM Definition Flash (Siemens Healthcare, Germany), using a consistent acquisition protocol (120 kVp, 0.625/0.6 mm slice thickness, 250 mAs, and 22 cm field of view). Images were reconstructed using filtered backprojection and a wide selection of reconstruction kernels. For each image set, the 2D NPS were estimated from the uniform section ofmore » the phantom. The 2D spectra were normalized by their integral value, radially averaged, and filtered by the human visual response function. A systematic kernel-by-kernel comparison across manufacturers was performed by computing the root mean square difference (RMSD) and the peak frequency difference (PFD) between the NPS from different kernels. GE and Siemens kernels were compared and kernel pairs that minimized the RMSD and |PFD| were identified. Results: The RMSD (|PFD|) values between the NPS of GE and Siemens kernels varied from 0.01 mm{sup 2} (0.002 mm{sup -1}) to 0.29 mm{sup 2} (0.74 mm{sup -1}). The GE kernels 'Soft,''Standard,''Chest,' and 'Lung' closely matched the Siemens kernels 'B35f,''B43f,''B41f,' and 'B80f' (RMSD < 0.05 mm{sup 2}, |PFD| < 0.02 mm{sup -1}, respectively). The GE 'Bone,''Bone+,' and 'Edge' kernels all matched most closely with Siemens 'B75f' kernel but with sizeable RMSD and |PFD| values up to 0.18 mm{sup 2} and 0.41 mm{sup -1}, respectively. These sizeable RMSD and |PFD| values corresponded to visually perceivable differences in the noise texture of the images. Conclusions: It is possible to use the NPS to quantitatively compare noise texture across CT systems. The degree to which similar texture across scanners could be achieved varies and is limited by the kernels available on each scanner.« less
Quantitative comparison of noise texture across CT scanners from different manufacturers.
Solomon, Justin B; Christianson, Olav; Samei, Ehsan
2012-10-01
To quantitatively compare noise texture across computed tomography (CT) scanners from different manufacturers using the noise power spectrum (NPS). The American College of Radiology CT accreditation phantom (Gammex 464, Gammex, Inc., Middleton, WI) was imaged on two scanners: Discovery CT 750HD (GE Healthcare, Waukesha, WI), and SOMATOM Definition Flash (Siemens Healthcare, Germany), using a consistent acquisition protocol (120 kVp, 0.625∕0.6 mm slice thickness, 250 mAs, and 22 cm field of view). Images were reconstructed using filtered backprojection and a wide selection of reconstruction kernels. For each image set, the 2D NPS were estimated from the uniform section of the phantom. The 2D spectra were normalized by their integral value, radially averaged, and filtered by the human visual response function. A systematic kernel-by-kernel comparison across manufacturers was performed by computing the root mean square difference (RMSD) and the peak frequency difference (PFD) between the NPS from different kernels. GE and Siemens kernels were compared and kernel pairs that minimized the RMSD and |PFD| were identified. The RMSD (|PFD|) values between the NPS of GE and Siemens kernels varied from 0.01 mm(2) (0.002 mm(-1)) to 0.29 mm(2) (0.74 mm(-1)). The GE kernels "Soft," "Standard," "Chest," and "Lung" closely matched the Siemens kernels "B35f," "B43f," "B41f," and "B80f" (RMSD < 0.05 mm(2), |PFD| < 0.02 mm(-1), respectively). The GE "Bone," "Bone+," and "Edge" kernels all matched most closely with Siemens "B75f" kernel but with sizeable RMSD and |PFD| values up to 0.18 mm(2) and 0.41 mm(-1), respectively. These sizeable RMSD and |PFD| values corresponded to visually perceivable differences in the noise texture of the images. It is possible to use the NPS to quantitatively compare noise texture across CT systems. The degree to which similar texture across scanners could be achieved varies and is limited by the kernels available on each scanner.
SU-F-J-91: Sparing Lung Function in Treatment Planning Using Dual Energy Tomography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lapointe, A; Bahig, H; Zerouali, K
2016-06-15
Purpose: To propose an alternate treatment plan that minimizes the dose to the functional lung tissues. In clinical situation, the evaluation of the lung functionality is typically derived from perfusion scintigraphy. However, such technique has spatial and temporal resolutions generally inferior to those of a CT scan. Alternatively, it is possible to evaluate pulmonary function by analysing the iodine concentration determined via contrast-enhanced dual energy CT (DECT) scan. Methods: Five lung cancer patients underwent a scintigraphy and a contrast-enhanced DECT scan (SOMATOM Definition Flash, Siemens). The iodine concentration was evaluated using the two-material decomposition method to produce a functional mapmore » of the lung. The validation of the approach is realized by comparison between the differential function computed by DECT and scintigraphy. The functional map is then used to redefine the V5 (volume of the organ that received more than 5 Gy during a radiotherapy treatment) to a novel functional parameter, the V5f. The V5f, that uses a volume weighted by its function level, can assist in evaluating optimal beam entry points for a specific treatment plan. Results: The results show that the differential functions obtained by scintigraphy and DECT are in good agreement with a mean difference of 6%. In specific cases, we are able to visually correlate low iodine concentration with abnormal pulmonary lung or cancerous tumors. The comparison between V5f and V5 has shown that some entry points can be better exploited and that new ones are now accessible, 2.34 times more in average, without increasing the V5f - thus allowing easier optimization of other planning objectives. Conclusion: In addition to the high-resolution DECT images, the iodine map provides local information used to detect potential functional heterogeneities in the 3D space. We propose that this information be used to calculate new functional dose parameters such as the V5f. The presenting author, Andreanne Lapointe, received a canadian scholarship from MITACS. Part of the funding is from the compagny Siemens.« less
Dose coefficients in pediatric and adult abdominopelvic CT based on 100 patient models
NASA Astrophysics Data System (ADS)
Tian, Xiaoyu; Li, Xiang; Segars, W. Paul; Frush, Donald P.; Paulson, Erik K.; Samei, Ehsan
2013-12-01
Recent studies have shown the feasibility of estimating patient dose from a CT exam using CTDIvol-normalized-organ dose (denoted as h), DLP-normalized-effective dose (denoted as k), and DLP-normalized-risk index (denoted as q). However, previous studies were limited to a small number of phantom models. The purpose of this work was to provide dose coefficients (h, k, and q) across a large number of computational models covering a broad range of patient anatomy, age, size percentile, and gender. The study consisted of 100 patient computer models (age range, 0 to 78 y.o.; weight range, 2-180 kg) including 42 pediatric models (age range, 0 to 16 y.o.; weight range, 2-80 kg) and 58 adult models (age range, 18 to 78 y.o.; weight range, 57-180 kg). Multi-detector array CT scanners from two commercial manufacturers (LightSpeed VCT, GE Healthcare; SOMATOM Definition Flash, Siemens Healthcare) were included. A previously-validated Monte Carlo program was used to simulate organ dose for each patient model and each scanner, from which h, k, and q were derived. The relationships between h, k, and q and patient characteristics (size, age, and gender) were ascertained. The differences in conversion coefficients across the scanners were further characterized. CTDIvol-normalized-organ dose (h) showed an exponential decrease with increasing patient size. For organs within the image coverage, the average differences of h across scanners were less than 15%. That value increased to 29% for organs on the periphery or outside the image coverage, and to 8% for distributed organs, respectively. The DLP-normalized-effective dose (k) decreased exponentially with increasing patient size. For a given gender, the DLP-normalized-risk index (q) showed an exponential decrease with both increasing patient size and patient age. The average differences in k and q across scanners were 8% and 10%, respectively. This study demonstrated that the knowledge of patient information and CTDIvol/DLP values may be used to estimate organ dose, effective dose, and risk index in abdominopelvic CT based on the coefficients derived from a large population of pediatric and adult patients.
Patino, Manuel; Fuentes, Jorge M; Hayano, Koichi; Kambadakone, Avinash R; Uyeda, Jennifer W; Sahani, Dushyant V
2015-02-01
OBJECTIVE. The objective of our study was to compare the performance of three hybrid iterative reconstruction techniques (IRTs) (ASiR, iDose4, SAFIRE) and their respective strengths for image noise reduction on low-dose CT examinations using filtered back projection (FBP) as the standard reference. Also, we compared the performance of these three hybrid IRTs with two model-based IRTs (Veo and IMR) for image noise reduction on low-dose examinations. MATERIALS AND METHODS. An anthropomorphic abdomen phantom was scanned at 100 and 120 kVp and different tube current-exposure time products (25-100 mAs) on three CT systems (for ASiR and Veo, Discovery CT750 HD; for iDose4 and IMR, Brilliance iCT; and for SAFIRE, Somatom Definition Flash). Images were reconstructed using FBP and using IRTs at various strengths. Nine noise measurements (mean ROI size, 423 mm(2)) on extracolonic fat for the different strengths of IRTs were recorded and compared with FBP using ANOVA. Radiation dose, which was measured as the volume CT dose index and dose-length product, was also compared. RESULTS. There were no significant differences in radiation dose and image noise among the scanners when FBP was used (p > 0.05). Gradual image noise reduction was observed with each increasing increment of hybrid IRT strength, with a maximum noise suppression of approximately 50% (48.2-53.9%). Similar noise reduction was achieved on the scanners by applying specific hybrid IRT strengths. Maximum noise reduction was higher on model-based IRTs (68.3-81.1%) than hybrid IRTs (48.2-53.9%) (p < 0.05). CONCLUSION. When constant scanning parameters are used, radiation dose and image noise on FBP are similar for CT scanners made by different manufacturers. Significant image noise reduction is achieved on low-dose CT examinations rendered with IRTs. The image noise on various scanners can be matched by applying specific hybrid IRT strengths. Model-based IRTs attain substantially higher noise reduction than hybrid IRTs irrespective of the radiation dose.
NASA Technical Reports Server (NTRS)
Suggs, Robert M.; Moser, D. E.
2015-01-01
The MSFC lunar impact monitoring program began in 2006 in support of environment definition for the Constellation (return to Moon) program. Work continued by the Meteoroid Environment Office after Constellation cancellation. Over 330 impacts have been recorded. A paper published in Icarus reported on the first 5 years of observations and 126 calibrated flashes. Icarus: http://www.sciencedirect.com/science/article/pii/S0019103514002243; ArXiv: http://arxiv.org/abs/1404.6458 A NASA Technical Memorandum on flash locations is in press
Technical Note: Development and validation of an open data format for CT projection data.
Chen, Baiyu; Duan, Xinhui; Yu, Zhicong; Leng, Shuai; Yu, Lifeng; McCollough, Cynthia
2015-12-01
Lack of access to projection data from patient CT scans is a major limitation for development and validation of new reconstruction algorithms. To meet this critical need, this work developed and validated a vendor-neutral format for CT projection data, which will further be employed to build a library of patient projection data for public access. A digital imaging and communication in medicine (DICOM)-like format was created for CT projection data (CT-PD), named the DICOM-CT-PD format. The format stores attenuation information in the DICOM image data block and stores parameters necessary for reconstruction in the DICOM header under various tags (51 tags to store the geometry and scan parameters and 9 tags to store patient information). To validate the accuracy and completeness of the new format, CT projection data from helical scans of the ACR CT accreditation phantom were acquired from two clinical CT scanners (Somatom Definition Flash, Siemens Healthcare, Forchheim, Germany and Discovery CT750 HD, GE Healthcare, Waukesha, WI). After decoding (by the authors for Siemens, by the manufacturer for GE), the projection data were converted to the DICOM-CT-PD format. Off-line CT reconstructions were performed by internal and external reconstruction researchers using only the information stored in the DICOM-CT-PD files and the DICOM-CT-PD field definitions. Compared with the commercially reconstructed CT images, the off-line reconstructed images created using the DICOM-CT-PD format are similar in terms of CT numbers (differences of 5 HU for the bone insert and -9 HU for the air insert), image noise (±1 HU), and low contrast detectability (6 mm rods visible in both). Because of different reconstruction approaches, slightly different in-plane and cross-plane high contrast spatial resolution were obtained compared to those reconstructed on the scanners (axial plane: GE off-line, 7 lp/cm; GE commercial, 7 lp/cm; Siemens off-line, 8 lp/cm; Siemens commercial, 7 lp/cm. Coronal plane: Siemens off-line, 6 lp/cm; Siemens commercial, 8 lp/cm). A vendor-neutral extended DICOM format has been developed that enables open sharing of CT projection data from third-generation CT scanners. Validation of the format showed that the geometric parameters and attenuation information in the DICOM-CT-PD file were correctly stored, could be retrieved with use of the provided instructions, and contained sufficient data for reconstruction of CT images that approximated those from the commercial scanner.
A stoichiometric calibration method for dual energy computed tomography
NASA Astrophysics Data System (ADS)
Bourque, Alexandra E.; Carrier, Jean-François; Bouchard, Hugo
2014-04-01
The accuracy of radiotherapy dose calculation relies crucially on patient composition data. The computed tomography (CT) calibration methods based on the stoichiometric calibration of Schneider et al (1996 Phys. Med. Biol. 41 111-24) are the most reliable to determine electron density (ED) with commercial single energy CT scanners. Along with the recent developments in dual energy CT (DECT) commercial scanners, several methods were published to determine ED and the effective atomic number (EAN) for polyenergetic beams without the need for CT calibration curves. This paper intends to show that with a rigorous definition of the EAN, the stoichiometric calibration method can be successfully adapted to DECT with significant accuracy improvements with respect to the literature without the need for spectrum measurements or empirical beam hardening corrections. Using a theoretical framework of ICRP human tissue compositions and the XCOM photon cross sections database, the revised stoichiometric calibration method yields Hounsfield unit (HU) predictions within less than ±1.3 HU of the theoretical HU calculated from XCOM data averaged over the spectra used (e.g., 80 kVp, 100 kVp, 140 kVp and 140/Sn kVp). A fit of mean excitation energy (I-value) data as a function of EAN is provided in order to determine the ion stopping power of human tissues from ED-EAN measurements. Analysis of the calibration phantom measurements with the Siemens SOMATOM Definition Flash dual source CT scanner shows that the present formalism yields mean absolute errors of (0.3 ± 0.4)% and (1.6 ± 2.0)% on ED and EAN, respectively. For ion therapy, the mean absolute errors for calibrated I-values and proton stopping powers (216 MeV) are (4.1 ± 2.7)% and (0.5 ± 0.4)%, respectively. In all clinical situations studied, the uncertainties in ion ranges in water for therapeutic energies are found to be less than 1.3 mm, 0.7 mm and 0.5 mm for protons, helium and carbon ions respectively, using a generic reconstruction algorithm (filtered back projection). With a more advanced method (sinogram affirmed iterative technique), the values become 1.0 mm, 0.5 mm and 0.4 mm for protons, helium and carbon ions, respectively. These results allow one to conclude that the present adaptation of the stoichiometric calibration yields a highly accurate method for characterizing tissue with DECT for ion beam therapy and potentially for photon beam therapy.
Evaluation of Internet websites about floaters and light flashes in patient education.
Barbosa, Andréa Lima; Martins, Elisabeth Nogueira
2007-01-01
Flashes of light and floaters are most commonly caused by posterior vitreous separation but may be associated with sight-threatening disorders. Prevention of severe sequelae requires prompt dilated eye examination. Thus, information dissemination is crucial. This study aimed to evaluate the quality of information about floaters and light flashes available for patients on the Internet. Cross-sectional study. In July 2005 we evaluated information available on the Internet regarding floaters and light flashes, using two search engines (MetaCrawler and MSN) and three key terms ("floaters", "dark spots eye", and "light flashes eye"). The quality of each website was evaluated using a score system. The sites were classified as academic, organizational or commercial. Readability, general quality of the website (based on: ownership, purpose, authorship, author qualification, attribution, interactivity, and currency) and quality of the specific content (definition, causes, epidemiology, diagnosis, treatment, and prognosis) were analyzed. Of 145 websites evaluated, 49 were included. Four sites (8.2%) were academic, 9 (18.4%) organizational, and 36 (73.4%) commercial. In the majority of the sites (53.0%) information was poor and quality was not correlated with website classification. Information about floaters and light flashes available on the Internet is poor.
Lang, Timothy J.; Pédeboy, Stéphane; Rison, William; Cerveny, Randall S.; Montanyà, Joan; Chauzy, Serge; MacGorman, Donald R.; Holle, Ronald L.; Ávila, Eldo E.; Zhang, Yijun; Carbin, Gregory; Mansell, Edward R.; Kuleshov, Yuriy; Peterson, Thomas C.; Brunet, Manola; Driouech, Fatima; Krahenbuhl, Daniel S.
2017-01-01
A World Meteorological Organization weather and climate extremes committee has judged that the world’s longest reported distance for a single lightning flash occurred with a horizontal distance of 321 km (199.5 mi) over Oklahoma in 2007, while the world’s longest reported duration for a single lightning flash is an event that lasted continuously for 7.74 seconds over southern France in 2012. In addition, the committee has unanimously recommended amendment of the AMS Glossary of Meteorology definition of lightning discharge as a “series of electrical processes taking place within 1 second” by removing the phrase “within one second” and replacing with “continuously.” Validation of these new world extremes (a) demonstrates the recent and on-going dramatic augmentations and improvements to regional lightning detection and measurement networks, (b) provides reinforcement regarding the dangers of lightning, and (c) provides new information for lightning engineering concerns. PMID:28111477
NASA Technical Reports Server (NTRS)
Pinsky, L. S.; Osborne, W. Z.; Bailey, J. V.
1975-01-01
A nuclear emulsion detector known as the Apollo Light Flash Moving Emulsion Detector (ALFMED) was designed: (1) to record tracks of primary cosmic rays; (2) to provide time-of-passage information via a relative plate translation technique; (3) to provide particle trajectory information; and (4) to fit into a masklike device that could be located about the head and eyes of an astronaut. An ALFMED device was worn by an astronaut observing light flashes for 60 minutes on each of the last two Apollo missions. During the Apollo 17 experiment seventeen separate flashes were reported by the observer. With one-third of the total plate area completely analyzed, two definite correlations have been found between Z greater than 8 cosmic ray nuclei traversing an eye and the reports of visual sensations.
Lang, Timothy J; Pédeboy, Stéphane; Rison, William; Cerveny, Randall S; Montanyà, Joan; Chauzy, Serge; MacGorman, Donald R; Holle, Ronald L; Ávila, Eldo E; Zhang, Yijun; Carbin, Gregory; Mansell, Edward R; Kuleshov, Yuriy; Peterson, Thomas C; Brunet, Manola; Driouech, Fatima; Krahenbuhl, Daniel S
2017-06-01
A World Meteorological Organization weather and climate extremes committee has judged that the world's longest reported distance for a single lightning flash occurred with a horizontal distance of 321 km (199.5 mi) over Oklahoma in 2007, while the world's longest reported duration for a single lightning flash is an event that lasted continuously for 7.74 seconds over southern France in 2012. In addition, the committee has unanimously recommended amendment of the AMS Glossary of Meteorology definition of lightning discharge as a "series of electrical processes taking place within 1 second" by removing the phrase "within one second" and replacing with "continuously." Validation of these new world extremes (a) demonstrates the recent and on-going dramatic augmentations and improvements to regional lightning detection and measurement networks, (b) provides reinforcement regarding the dangers of lightning, and (c) provides new information for lightning engineering concerns.
Turner, Sally; Wylde, Julie; Langham, Martin; Morrow, Andrew
2014-09-01
An investigation of how emergency vehicle lighting (EVL) can be improved is reported with reference to an analysis of police vehicle road traffic accidents (Study 1). In Study 2, 37 regular drivers were shown film clips of a marked police vehicle, in which flash rate (1 Hz, 4 Hz) and pattern (single, triple pulse) were varied on the blue Light Emitting Diode (LED) roofbar. Results indicate a 4 Hz flash rate conveys greater urgency than a 1 Hz rate, while a 1 Hz, single flash combination was ranked the least urgent of all combinations. Participants claimed they would leave significantly more space before pulling out in front of an approaching police car (gap acceptance) in the 4 Hz single pulse condition in comparison to other EVL combinations. The preliminary implications for which flash characteristics could prove most optimal for emergency service use are discussed with regard to effects on driver perception and expected driving behaviour. Copyright © 2013 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Bitumen) is a black or dark brown solid or semi-solid thermo-plastic material possessing waterproofing and... hydrogen ratio. It is essentially non-volatile at ambient temperatures with closed cup flash point of 445...
Code of Federal Regulations, 2011 CFR
2011-07-01
... dark brown solid or semi-solid thermo-plastic material possessing waterproofing and adhesive properties... essentially non-volatile at ambient temperatures with closed cup flash point of 445 °F (230 °C) or greater...
Smet, Stéphanie; Pötter, Richard; Haie-Meder, Christine; Lindegaard, Jacob C; Schulz-Juergenliemk, Ina; Mahantshetty, Umesh; Segedin, Barbara; Bruheim, Kjersti; Hoskin, Peter; Rai, Bhavana; Huang, Fleur; Cooper, Rachel; van Limbergen, Erik; Tanderup, Kari; Kirchheiner, Kathrin
2018-04-04
To evaluate the pattern of manifestation of fatigue, insomnia and hot flashes within the prospective, observational, multi-center EMBRACE study. Morbidity was prospectively assessed according to CTCAE v.3 and patient-reported outcome with EORTC QLQ-C30/CX24 at baseline and regular follow-up. Analyses of crude incidence, prevalence rates and actuarial estimates were performed. A total of 1176 patients were analyzed with a median follow-up of 27 months. At baseline, CTCAE G1/G2 prevalence rates for fatigue were 29%/6.2%, for insomnia 18%/3.1% and for hot flashes 7.9%/1.6% with respective 3-year prevalence rates of 29%/6.8%, 17%/4.4% and 19%/5.9%. Similar patterns of manifestation were seen in patient-reported EORTC outcomes. The 3-year actuarial estimates for G ≥ 3 CTCAE fatigue, insomnia and hot flashes were 5.5%, 4.7% and 1.9%. Younger age was associated with significantly higher risk for fatigue, insomnia and hot flashes. Fatigue, insomnia and hot flashes occurred mainly in the mild to moderate range. Fatigue and insomnia were already present before treatment and showed minor fluctuations or recovery during follow-up, whereas hot flashes showed a considerable increase after treatment. More research is needed to evaluate contributing risk factors in order to define intervention strategies. Copyright © 2018 Elsevier B.V. All rights reserved.
Effect of topogram-tube angle combination on CT radiation dose reduction
NASA Astrophysics Data System (ADS)
Shim, J.; Yoon, M.
2017-09-01
This study assessed the ability of various types of topograms, when used with an automatic tube current modulation (ATCM) technique, to reduce radiation dose from computed tomography (CT) scans. Three types of topograms were used with the ATCM technique: (i) anteroposterior (AP) topograms alone, (ii) AP topograms followed by lateral topograms, and (iii) lateral topograms followed by AP topograms. Various regions (chest, abdomen and whole-body) of a humanoid phantom were scanned at several tube voltages (80, 100 and 120 kVp) with the selected topograms. Although the CT dose depended on the order of topograms, the CT dose with respect to patient positioning depended on the number of topograms performed. The magnitude of the difference in CT dose between number and order of topograms was greater for the scans of the abdomen than the chest. These results suggest that, for the Siemens SOMATOM Definition AS CT scanner, choosing the right combination of CT scan conditions with the ATCM technique can minimize radiation dose to a patient.
MacLaughlan David, Shannon; Salzillo, Sandra; Bowe, Patrick; Scuncio, Sandra; Malit, Bridget; Raker, Christina; Gass, Jennifer S; Granai, C O; Dizon, Don S
2013-01-01
Objectives To compare the efficacy of hypnotherapy versus gabapentin for the treatment of hot flashes in breast cancer survivors, and to evaluate the feasibility of conducting a clinical trial comparing a drug with a complementary or alternative method (CAM). Design Prospective randomised trial. Setting Breast health centre of a tertiary care centre. Participants 15 women with a personal history of breast cancer or an increased risk of breast cancer who reported at least one daily hot flash. Interventions Gabapentin 900 mg daily in three divided doses (control) compared with standardised hypnotherapy. Participation lasted 8 weeks. Outcome measures The primary endpoints were the number of daily hot flashes and hot flash severity score (HFSS). The secondary endpoint was the Hot Flash Related Daily Interference Scale (HFRDIS). Results 27 women were randomised and 15 (56%) were considered evaluable for the primary endpoint (n=8 gabapentin, n=7 hypnotherapy). The median number of daily hot flashes at enrolment was 4.5 in the gabapentin arm and 5 in the hypnotherapy arm. HFSS scores were 7.5 in the gabapentin arm and 10 in the hypnotherapy arm. After 8 weeks, the median number of daily hot flashes was reduced by 33.3% in the gabapentin arm and by 80% in the hypnotherapy arm. The median HFSS was reduced by 33.3% in the gabapentin arm and by 85% in the hypnotherapy arm. HFRDIS scores improved by 51.6% in the gabapentin group and by 55.2% in the hypnotherapy group. There were no statistically significant differences between groups. Conclusions Hypnotherapy and gabapentin demonstrate efficacy in improving hot flashes. A definitive trial evaluating traditional interventions against CAM methods is feasible, but not without challenges. Further studies aimed at defining evidence-based recommendations for CAM are necessary. Trial registration clinicaltrials.gov (NCT00711529). PMID:24022390
DOE Office of Scientific and Technical Information (OSTI.GOV)
Solomon, Justin, E-mail: justin.solomon@duke.edu; Samei, Ehsan
2014-09-15
Purpose: Quantum noise properties of CT images are generally assessed using simple geometric phantoms with uniform backgrounds. Such phantoms may be inadequate when assessing nonlinear reconstruction or postprocessing algorithms. The purpose of this study was to design anatomically informed textured phantoms and use the phantoms to assess quantum noise properties across two clinically available reconstruction algorithms, filtered back projection (FBP) and sinogram affirmed iterative reconstruction (SAFIRE). Methods: Two phantoms were designed to represent lung and soft-tissue textures. The lung phantom included intricate vessel-like structures along with embedded nodules (spherical, lobulated, and spiculated). The soft tissue phantom was designed based onmore » a three-dimensional clustered lumpy background with included low-contrast lesions (spherical and anthropomorphic). The phantoms were built using rapid prototyping (3D printing) technology and, along with a uniform phantom of similar size, were imaged on a Siemens SOMATOM Definition Flash CT scanner and reconstructed with FBP and SAFIRE. Fifty repeated acquisitions were acquired for each background type and noise was assessed by estimating pixel-value statistics, such as standard deviation (i.e., noise magnitude), autocorrelation, and noise power spectrum. Noise stationarity was also assessed by examining the spatial distribution of noise magnitude. The noise properties were compared across background types and between the two reconstruction algorithms. Results: In FBP and SAFIRE images, noise was globally nonstationary for all phantoms. In FBP images of all phantoms, and in SAFIRE images of the uniform phantom, noise appeared to be locally stationary (within a reasonably small region of interest). Noise was locally nonstationary in SAFIRE images of the textured phantoms with edge pixels showing higher noise magnitude compared to pixels in more homogenous regions. For pixels in uniform regions, noise magnitude was reduced by an average of 60% in SAFIRE images compared to FBP. However, for edge pixels, noise magnitude ranged from 20% higher to 40% lower in SAFIRE images compared to FBP. SAFIRE images of the lung phantom exhibited distinct regions with varying noise texture (i.e., noise autocorrelation/power spectra). Conclusions: Quantum noise properties observed in uniform phantoms may not be representative of those in actual patients for nonlinear reconstruction algorithms. Anatomical texture should be considered when evaluating the performance of CT systems that use such nonlinear algorithms.« less
Panzer, Stephanie; Pernter, Patrizia; Piombino-Mascali, Dario; Jankauskas, Rimantas; Zesch, Stephanie; Rosendahl, Wilfried; Hotz, Gerhard; Zink, Albert R
2017-12-01
Purpose Soft tissues make a skeleton into a mummy and they allow for a diagnosis beyond osteology. Following the approach of structured reporting in clinical radiology, a recently developed checklist was used to evaluate the soft tissue preservation status of the Tyrolean Iceman using computed tomography (CT). The purpose of this study was to apply the "Checklist and Scoring System for the Assessment of Soft Tissue Preservation in CT Examinations of Human Mummies" to the Tyrolean Iceman, and to compare the Iceman's soft tissue preservation score to the scores calculated for other mummies. Materials and Methods A whole-body (CT) (SOMATOM Definition Flash, Siemens, Forchheim, Germany) consisting of five scans, performed in January 2013 in the Department of Radiodiagnostics, Central Hospital, Bolzano, was used (slice thickness 0.6 mm; kilovolt ranging from 80 to 140). For standardized evaluation the "CT Checklist and Scoring System for the Assessment of Soft Tissue Preservation in Human Mummies" was used. Results All checkpoints under category "A. Soft Tissues of Head and Musculoskeletal System" and more than half in category "B. Organs and Organ Systems" were observed. The scoring system accounted for a total score of 153 (out of 200). The comparison of the scores between the Iceman and three mummy collections from Vilnius, Lithuania, and Palermo, Sicily, as well as one Egyptian mummy resulted in overall higher soft tissue preservation scores for the Iceman. Conclusion Application of the checklist allowed for standardized assessment and documentation of the Iceman's soft tissue preservation status. The scoring system allowed for a quantitative comparison between the Iceman and other mummies. The Iceman showed remarkable soft tissue preservation. Key Points · The approach of structured reporting can be transferred to paleoradiology.. · The checklist allowed for standardized soft tissue assessment and documentation.. · The scoring system facilitated a quantitative comparison among mummies.. · Based on CT, the Tyrolean Iceman demonstrated remarkable soft tissue preservation.. Citation Format · Panzer S, Pernter P, Piombino-Mascali D et al. Checklist and Scoring System for the Assessment of Soft Tissue Preservation in CT Examinations of Human Mummies: Application to the Tyrolean Iceman. Fortschr Röntgenstr 2017; 189: 1152 - 1160. © Georg Thieme Verlag KG Stuttgart · New York.
Code of Federal Regulations, 2010 CFR
2010-07-01
... hydrogen ratio. It is essentially non-volatile at ambient temperatures with closed cup flash point of 445... recordkeeping and reporting only, compressors are considered equipment. In hydrogen service means that a... sufficient storage facilities for the product. For the purpose of this subpart, process unit includes any...
Code of Federal Regulations, 2011 CFR
2011-07-01
... flash steam from the digester or live steam. Closed-vent system means a system that is not open to the... this subpart, including emissions from individual process vents, stacks, open pieces of process... stock chests, and their associated vacuum pumps, filtrate tanks, foam breakers or tanks, and any other...
Code of Federal Regulations, 2010 CFR
2010-07-01
... flash steam from the digester or live steam. Closed-vent system means a system that is not open to the... this subpart, including emissions from individual process vents, stacks, open pieces of process... stock chests, and their associated vacuum pumps, filtrate tanks, foam breakers or tanks, and any other...
Code of Federal Regulations, 2012 CFR
2012-07-01
... flash steam from the digester or live steam. Closed-vent system means a system that is not open to the... this subpart, including emissions from individual process vents, stacks, open pieces of process... stock chests, and their associated vacuum pumps, filtrate tanks, foam breakers or tanks, and any other...
Code of Federal Regulations, 2011 CFR
2011-07-01
... wood in white liquor, and associated flash tank(s), blow tank(s), chip steamer(s), and condenser(s). (e... condenser(s) and hotwell(s) used to concentrate the spent cooking liquid that is separated from the pulp... calcium oxide. (o) Condensate stripper system means a column, and associated condensers, used to strip...
40 CFR 63.2872 - What definitions apply to this subpart?
Code of Federal Regulations, 2013 CFR
2013-07-01
... vegetable oil and crude meal products, such as animal feed. Corn germ dry milling means a source that processes corn germ that has been separated from the other corn components using a “dry” process of... to solvent recovery equipment such as extractors, desolventizer-toasters/dryer-coolers, flash...
40 CFR 63.2872 - What definitions apply to this subpart?
Code of Federal Regulations, 2014 CFR
2014-07-01
... vegetable oil and crude meal products, such as animal feed. Corn germ dry milling means a source that processes corn germ that has been separated from the other corn components using a “dry” process of... to solvent recovery equipment such as extractors, desolventizer-toasters/dryer-coolers, flash...
40 CFR 63.2872 - What definitions apply to this subpart?
Code of Federal Regulations, 2012 CFR
2012-07-01
... vegetable oil and crude meal products, such as animal feed. Corn germ dry milling means a source that processes corn germ that has been separated from the other corn components using a “dry” process of... to solvent recovery equipment such as extractors, desolventizer-toasters/dryer-coolers, flash...
Code of Federal Regulations, 2013 CFR
2013-07-01
... truck including hoods, fenders, cargo boxes, doors, and grill opening panels. Bake oven means a device...-duty truck assembly lines between the coating application system (dip tank or spray booth) and the bake oven. Guide coat operation means the guide coat spray booth, flash-off area and bake oven(s) which are...
Code of Federal Regulations, 2014 CFR
2014-07-01
... truck including hoods, fenders, cargo boxes, doors, and grill opening panels. Bake oven means a device...-duty truck assembly lines between the coating application system (dip tank or spray booth) and the bake oven. Guide coat operation means the guide coat spray booth, flash-off area and bake oven(s) which are...
Code of Federal Regulations, 2012 CFR
2012-07-01
... truck including hoods, fenders, cargo boxes, doors, and grill opening panels. Bake oven means a device...-duty truck assembly lines between the coating application system (dip tank or spray booth) and the bake oven. Guide coat operation means the guide coat spray booth, flash-off area and bake oven(s) which are...
Code of Federal Regulations, 2010 CFR
2010-07-01
... truck including hoods, fenders, cargo boxes, doors, and grill opening panels. Bake oven means a device...-duty truck assembly lines between the coating application system (dip tank or spray booth) and the bake oven. Guide coat operation means the guide coat spray booth, flash-off area and bake oven(s) which are...
Code of Federal Regulations, 2011 CFR
2011-07-01
... truck including hoods, fenders, cargo boxes, doors, and grill opening panels. Bake oven means a device...-duty truck assembly lines between the coating application system (dip tank or spray booth) and the bake oven. Guide coat operation means the guide coat spray booth, flash-off area and bake oven(s) which are...
Use of Mobile Video to Enhance Situational Awareness in HA/DR Missions
2012-09-01
challenges . Although many definitions have been proposed so far, Mica R. Endsley describes “situational awareness” as: [T]he perception of the...Player, QuickTime, Flash Player, VLC Media Player, HTML 5 Video and DivX Web Player. This feature helps overcome a usual handicap that developers
Code of Federal Regulations, 2012 CFR
2012-07-01
... cooking (digesting) wood chips in a water solution of sodium hydroxide and sodium sulfide (white liquor... any operation in which pulp is produced from wood by cooking (digesting) wood chips in a solution of... wood in white liquor, and associated flash tank(s), blow tank(s), chip steamer(s), and condenser(s). (e...
Code of Federal Regulations, 2013 CFR
2013-07-01
... cooking (digesting) wood chips in a water solution of sodium hydroxide and sodium sulfide (white liquor... any operation in which pulp is produced from wood by cooking (digesting) wood chips in a solution of... wood in white liquor, and associated flash tank(s), blow tank(s), chip steamer(s), and condenser(s). (e...
Code of Federal Regulations, 2014 CFR
2014-07-01
... cooking (digesting) wood chips in a water solution of sodium hydroxide and sodium sulfide (white liquor... any operation in which pulp is produced from wood by cooking (digesting) wood chips in a solution of... wood in white liquor, and associated flash tank(s), blow tank(s), chip steamer(s), and condenser(s). (e...
NASA Astrophysics Data System (ADS)
Richards, Taylor; Sturgeon, Gregory M.; Ramirez-Giraldo, Juan Carlos; Rubin, Geoffrey; Segars, Paul; Samei, Ehsan
2017-03-01
The purpose of this study was to quantify the accuracy of coronary computed tomography angiography (CTA) stenosis measurements using newly developed physical coronary plaque models attached to a base dynamic cardiac phantom (Shelley Medical DHP-01). Coronary plaque models (5 mm diameter, 50% stenosis, and 32 mm long) were designed and 3D-printed with tissue equivalent materials (calcified plaque with iodine enhanced lumen). Realistic cardiac motion was achieved by fitting known cardiac motion vectors to left ventricle volume-time curves to create synchronized heart motion profiles executed by the base cardiac phantom. Realistic coronary CTA acquisition was accomplished by synthesizing corresponding ECG waveforms for gating and reconstruction purposes. All scans were acquired using a retrospective gating technique on a dual-source CT system (Siemens SOMATOM FLASH) with 75ms temporal resolution. Multi-planar reformatted images were reconstructed along vessel centerlines and the enhanced lumens were manually segmented by 5 independent operators. On average, the stenosis measurement accuracy was 0.9% positive bias for the motion free condition (0 bpm). The measurement accuracy monotonically decreased to 18.5% negative bias at 90 bpm. Contrast-tonoise (CNR), vessel circularity, and segmentation conformity also decreased monotonically with increasing heart rate. These results demonstrate successful implementation of the base cardiac phantom with 3D-printed coronary plaque models, adjustable motion profiles, and coordinated ECG waveforms. They further show the utility of the model to ascertain metrics of coronary CT accuracy and image quality under a variety of plaque, motion, and acquisition conditions.
Regional Differences in Tropical Lightning Distributions.
NASA Astrophysics Data System (ADS)
Boccippio, Dennis J.; Goodman, Steven J.; Heckman, Stan
2000-12-01
Observations from the National Aeronautics and Space Administration Optical Transient Detector (OTD) and Tropical Rainfall Measuring Mission (TRMM)-based Lightning Imaging Sensor (LIS) are analyzed for variability between land and ocean, various geographic regions, and different (objectively defined) convective `regimes.' The bulk of the order-of-magnitude differences between land and ocean regional flash rates are accounted for by differences in storm spacing (density) and/or frequency of occurrence, rather than differences in storm instantaneous flash rates, which only vary by a factor of 2 on average. Regional variability in cell density and cell flash rates closely tracks differences in 85-GHz microwave brightness temperatures. Monotonic relationships are found with the gross moist stability of the tropical atmosphere, a large-scale `adjusted state' parameter. This result strongly suggests that it will be possible, using TRMM observations, to objectively test numerical or theoretical predictions of how mesoscale convective organization interacts with the larger-scale environment. Further parameters are suggested for a complete objective definition of tropical convective regimes.
Optimizing Precipitation Thresholds for Best Correlation Between Dry Lightning and Wildfires
NASA Astrophysics Data System (ADS)
Vant-Hull, Brian; Thompson, Tollisha; Koshak, William
2018-03-01
This work examines how to adjust the definition of "dry lightning" in order to optimize the correlation between dry lightning flash count and the climatology of large (>400 km2) lightning-ignited wildfires over the contiguous United States (CONUS). The National Lightning Detection Network™ and National Centers for Environmental Prediction Stage IV radar-based, gauge-adjusted precipitation data are used to form climatic data sets. For a 13 year analysis period over CONUS, a correlation of 0.88 is found between annual totals of wildfires and dry lightning. This optimal correlation is found by defining dry lightning as follows: on a 0.1° hourly grid, a precipitation threshold of no more than 0.3 mm may accumulate during any hour over a period of 3-4 days preceding the flash. Regional optimized definitions vary. When annual totals are analyzed as done here, no clear advantage is found by weighting positive polarity cloud-to-ground (+CG) lightning differently than -CG lightning. The high variability of dry lightning relative to the precipitation and lightning from which it is derived suggests it would be an independent and useful climate indicator.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Long, Daniel J.; Lee, Choonsik; Tien, Christopher
2013-01-15
Purpose: To validate the accuracy of a Monte Carlo source model of the Siemens SOMATOM Sensation 16 CT scanner using organ doses measured in physical anthropomorphic phantoms. Methods: The x-ray output of the Siemens SOMATOM Sensation 16 multidetector CT scanner was simulated within the Monte Carlo radiation transport code, MCNPX version 2.6. The resulting source model was able to perform various simulated axial and helical computed tomographic (CT) scans of varying scan parameters, including beam energy, filtration, pitch, and beam collimation. Two custom-built anthropomorphic phantoms were used to take dose measurements on the CT scanner: an adult male and amore » 9-month-old. The adult male is a physical replica of University of Florida reference adult male hybrid computational phantom, while the 9-month-old is a replica of University of Florida Series B 9-month-old voxel computational phantom. Each phantom underwent a series of axial and helical CT scans, during which organ doses were measured using fiber-optic coupled plastic scintillator dosimeters developed at University of Florida. The physical setup was reproduced and simulated in MCNPX using the CT source model and the computational phantoms upon which the anthropomorphic phantoms were constructed. Average organ doses were then calculated based upon these MCNPX results. Results: For all CT scans, good agreement was seen between measured and simulated organ doses. For the adult male, the percent differences were within 16% for axial scans, and within 18% for helical scans. For the 9-month-old, the percent differences were all within 15% for both the axial and helical scans. These results are comparable to previously published validation studies using GE scanners and commercially available anthropomorphic phantoms. Conclusions: Overall results of this study show that the Monte Carlo source model can be used to accurately and reliably calculate organ doses for patients undergoing a variety of axial or helical CT examinations on the Siemens SOMATOM Sensation 16 scanner.« less
1988-04-01
devices of the language. When you think of a television show, a mental picture quickly flashes in your mind of the actor or actress who represents that...iteratively determine and validate what data the user needs displayed, how should will look ( i.e. color vs black and while and resolution) to the user and
Slebocki, Karin; Kraus, Bastian; Chang, De-Hua; Hellmich, Martin; Maintz, David; Bangard, Christopher
To assess correlation between attenuation measurements of incidental findings in abdominal second generation dual-energy computed tomography (CT) on true noncontrast (TNC) and virtual noncontrast (VNC) images. Sixty-three patients underwent arterial dual-energy CT (Somatom Definition Flash, Siemens; pitch factor, 0.75-1.0; gantry rotation time, 0.28 seconds) after endovascular aneurysm repair, consisting of a TNC single energy CT scan (collimation, 128 × 0.6 mm; 120 kVp) and a dual-energy arterial phase scan (collimation, 32 × 0.6 mm, 140 and 100 kVp; blended, 120 kVp data set). Attenuation measurements in Hounsfield units (HU) of liver parenchyma and incidental findings like renal and hepatic cysts and adrenal masses on TNC and VNC images were done by drawing regions of interest. Statistical analysis was performed by paired t test and Pearson correlation. Incidental findings were detected in 56 (89%) patients. There was excellent correlation for both renal (n = 40) and hepatic cysts (n = 12) as well as adrenal masses (n = 6) with a Pearson correlation of 0.896, 0.800, and 0.945, respectively, and mean attenuation values on TNC and VNC images of 10.6 HU ± 12.8 versus 5.1 HU ± 17.5 (attenuation value range from -8.8 to 59.1 HU vs -11.8 to 73.4 HU), 6.4 HU ± 5.8 versus 6.3 HU ± 4.6 (attenuation value range from 2.0 to 16.2 HU vs -3.0 to 15.9 HU), and 12.8 HU ± 11.2 versus 12.4 HU ± 10.2 (attenuation value range from -2.3 to 27.5 HU vs -2.2 to 23.6 HU), respectively. As proof of principle, liver parenchyma measurements also showed excellent correlation between TNC and VNC (n = 40) images with a Pearson correlation of 0.839 and mean attenuation values on TNC and VNC images of 47.2 HU ± 10.5 versus 43.8 HU ± 8.7 (attenuation value range from 21.9 to 60.2 HU vs 4.5 to 65.3 HU). In conclusion, attenuation measurements of incidental findings like renal cysts or adrenal masses on TNC and VNC images derived from second generation dual-energy CT scans show excellent correlation providing considerable dose savings, favorable for future application in clinical routine.
Active Flash: Performance-Energy Tradeoffs for Out-of-Core Processing on Non-Volatile Memory Devices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boboila, Simona; Kim, Youngjae; Vazhkudai, Sudharshan S
2012-01-01
In this abstract, we study the performance and energy tradeoffs involved in migrating data analysis into the flash device, a process we refer to as Active Flash. The Active Flash paradigm is similar to 'active disks', which has received considerable attention. Active Flash allows us to move processing closer to data, thereby minimizing data movement costs and reducing power consumption. It enables true out-of-core computation. The conventional definition of out-of-core solvers refers to an approach to process data that is too large to fit in the main memory and, consequently, requires access to disk. However, in Active Flash, processing outsidemore » the host CPU literally frees the core and achieves real 'out-of-core' analysis. Moving analysis to data has long been desirable, not just at this level, but at all levels of the system hierarchy. However, this requires a detailed study on the tradeoffs involved in achieving analysis turnaround under an acceptable energy envelope. To this end, we first need to evaluate if there is enough computing power on the flash device to warrant such an exploration. Flash processors require decent computing power to run the internal logic pertaining to the Flash Translation Layer (FTL), which is responsible for operations such as address translation, garbage collection (GC) and wear-leveling. Modern SSDs are composed of multiple packages and several flash chips within a package. The packages are connected using multiple I/O channels to offer high I/O bandwidth. SSD computing power is also expected to be high enough to exploit such inherent internal parallelism within the drive to increase the bandwidth and to handle fast I/O requests. More recently, SSD devices are being equipped with powerful processing units and are even embedded with multicore CPUs (e.g. ARM Cortex-A9 embedded processor is advertised to reach 2GHz frequency and deliver 5000 DMIPS; OCZ RevoDrive X2 SSD has 4 SandForce controllers, each with 780MHz max frequency Tensilica core). Efforts that take advantage of the available computing cycles on the processors on SSDs to run auxiliary tasks other than actual I/O requests are beginning to emerge. Kim et al. investigate database scan operations in the context of processing on the SSDs, and propose dedicated hardware logic to speed up scans. Also, cluster architectures have been explored, which consist of low-power embedded CPUs coupled with small local flash to achieve fast, parallel access to data. Processor utilization on SSD is highly dependent on workloads and, therefore, they can be idle during periods with no I/O accesses. We propose to use the available processing capability on the SSD to run tasks that can be offloaded from the host. This paper makes the following contributions: (1) We have investigated Active Flash and its potential to optimize the total energy cost, including power consumption on the host and the flash device; (2) We have developed analytical models to analyze the performance-energy tradeoffs for Active Flash, by treating the SSD as a blackbox, this is particularly valuable due to the proprietary nature of the SSD internal hardware; and (3) We have enhanced a well-known SSD simulator (from MSR) to implement 'on-the-fly' data compression using Active Flash. Our results provide a window into striking a balance between energy consumption and application performance.« less
Absolute rate of the reaction of C l(2P) with methane from 200-500 K
NASA Technical Reports Server (NTRS)
Whytock, D. A.; Lee, J. H.; Michael, J. V.; Payne, W. A.; Stief, L. J.
1976-01-01
Rate constants for the reaction of atomic chlorine with methane have been measured from 200-500K using the flash photolysis-resonance fluorescence technique. When the results from fourteen equally spaced experimental determinations are plotted in Arrhenius form a definite curvature is noted. The results are compared to previous work and are theoretically discussed.
29 CFR 1910.123 - Dipping and coating operations: Coverage and definitions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... tank containing a liquid other than water. It applies when you use the liquid in the tank or its vapor... combustion, independent of any other source of heat. Combustible liquid means a liquid having a flash point of 100 °F (37.8 °C) or above. Dip tank means a container holding a liquid other than water and that...
29 CFR 1910.123 - Dipping and coating operations: Coverage and definitions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... tank containing a liquid other than water. It applies when you use the liquid in the tank or its vapor... combustion, independent of any other source of heat. Combustible liquid means a liquid having a flash point of 100 °F (37.8 °C) or above. Dip tank means a container holding a liquid other than water and that...
Castorina, Sergio; Luca, Tonia; Privitera, Giovanna; Riccioli, Vincenzo
2010-01-01
In this paper, we describe two cases of anomalous origin of the left coronary artery and two cases of aneurysm on the left coronary artery. Detailed three-dimensional images were acquired by the multislice computed tomography (MSCT) SOMATOM Sensation Cardiac 64 during clinical studies of cardiac diseases. Copyright 2010. Published by Elsevier Inc.
NASA Astrophysics Data System (ADS)
Bogan, Michael J.; Starodub, Dmitri; Hampton, Christina Y.; Sierra, Raymond G.
2010-10-01
The first of its kind, the Free electron LASer facility in Hamburg, FLASH, produces soft x-ray pulses with unprecedented properties (10 fs, 6.8-47 nm, 1012 photons per pulse, 20 µm diameter). One of the seminal FLASH experiments is single-pulse coherent x-ray diffractive imaging (CXDI). CXDI utilizes the ultrafast and ultrabright pulses to overcome resolution limitations in x-ray microscopy imposed by x-ray-induced damage to the sample by 'diffracting before destroying' the sample on sub-picosecond timescales. For many lensless imaging algorithms used for CXDI it is convenient when the data satisfy an oversampling constraint that requires the sample to be an isolated object, i.e. an individual 'free-standing' portion of disordered matter delivered to the centre of the x-ray focus. By definition, this type of matter is an aerosol. This paper will describe the role of aerosol science methodologies used for the validation of the 'diffract before destroy' hypothesis and the execution of the first single-particle CXDI experiments being developed for biological imaging. FLASH CXDI now enables the highest resolution imaging of single micron-sized or smaller airborne particulate matter to date while preserving the native substrate-free state of the aerosol. Electron microscopy offers higher resolution for single-particle analysis but the aerosol must be captured on a substrate, potentially modifying the particle morphology. Thus, FLASH is poised to contribute significant advancements in our knowledge of aerosol morphology and dynamics. As an example, we simulate CXDI of combustion particle (soot) morphology and introduce the concept of extracting radius of gyration of fractal aggregates from single-pulse x-ray diffraction data. Future upgrades to FLASH will enable higher spatially and temporally resolved single-particle aerosol dynamics studies, filling a critical technological need in aerosol science and nanotechnology. Many of the methodologies described for FLASH will directly translate to use at hard x-ray free electron lasers.
The development of a flash flood severity index
NASA Astrophysics Data System (ADS)
Schroeder, Amanda J.; Gourley, Jonathan J.; Hardy, Jill; Henderson, Jen J.; Parhi, Pradipta; Rahmani, Vahid; Reed, Kimberly A.; Schumacher, Russ S.; Smith, Brianne K.; Taraldsen, Matthew J.
2016-10-01
Flash flooding is a high impact weather event that requires clear communication regarding severity and potential hazards among forecasters, researchers, emergency managers, and the general public. Current standards used to communicate these characteristics include return periods and the United States (U.S.) National Weather Service (NWS) 4-tiered river flooding severity scale. Return periods are largely misunderstood, and the NWS scale is limited to flooding on gauged streams and rivers, often leaving out heavily populated urban corridors. To address these shortcomings, a student-led group of interdisciplinary researchers came together in a collaborative effort to develop an impact-based Flash Flood Severity Index (FFSI). The index was proposed as a damage-based, post-event assessment tool, and preliminary work toward the creation of this index has been completed and presented here. Numerous case studies were analyzed to develop the preliminary outline for the FFSI, and three examples of such cases are included in this paper. The scale includes five impact-based categories ranging from Category 1 very minor flooding to Category 5 catastrophic flooding. Along with the numerous case studies used to develop the initial outline of the scale, empirical data in the form of semi-structured interviews were conducted with multiple NWS forecasters across the country and their responses were analyzed to gain more perspective on the complicated nature of flash flood definitions and which tools were found to be most useful. The feedback from these interviews suggests the potential for acceptance of such an index if it can account for specific challenges.
NASA Astrophysics Data System (ADS)
Llasat, Maria Carmen; Marcos, Raul; Turco, Marco; Gilabert, Joan; Llasat-Botija, Montserrat
2016-10-01
The aim of this paper is to analyse the potential relationship between flash flood events and convective precipitation in Catalonia, as well as any related trends. The paper starts with an overview of flash floods and their trends in the Mediterranean region, along with their associated factors, followed by the definition of, identification of, and trends in convective precipitation. After this introduction the paper focuses on the north-eastern Iberian Peninsula, for which there is a long-term precipitation series (since 1928) of 1-min precipitation from the Fabra Observatory, as well as a shorter (1996-2011) but more extensive precipitation series (43 rain gauges) of 5-min precipitation. Both series have been used to characterise the degree of convective contribution to rainfall, introducing the β parameter as the ratio between convective precipitation versus total precipitation in any period. Information about flood events was obtained from the INUNGAMA database (a flood database created by the GAMA team), with the aim of finding any potential links to convective precipitation. These flood data were gathered using information on damage where flood is treated as a multifactorial risk, and where any trend or anomaly might have been caused by one or more factors affecting hazard, vulnerability or exposure. Trend analysis has shown an increase in flash flood events. The fact that no trends were detected in terms of extreme values of precipitation on a daily scale, nor on the associated ETCCDI (Expert Team on Climate Change Detection and Indices) extreme index, could point to an increase in vulnerability, an increase in exposure, or changes in land use. However, the summer increase in convective precipitation was concentrated in less torrential events, which could partially explain this positive trend in flash flood events. The β parameter has been also used to characterise the type of flood event according to the features of the precipitation. The highest values correspond to short and local events, usually with daily β values above 0.5, while the minimum threshold of daily β for catastrophic flash floods is 0.31.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gurtovoi, G.K.; Burdianskaya, E.O.
1960-01-01
The primary substrate excited by threshold doses of x radiation of the normal human eye causes perception of a light flash in the retinal region. The threshold dose for the retina is about 1 mr; the threshold absorbed dose is about 1 mrad. Persons with a removed eyeball, on irradiation of the operated region with a frontal x-ray beam, perceive a flash of light at definite doses of radiation. Six persons taking part in an experiment saw a flash at doses of 17 to 150 mr (different observers saw flash at different doses) and did not see flash at dosesmore » of 5 to 90 mr. The cause of x-ray phosphene on frontal irradiation of the region of the removed eye with threshold doses is neither the reactivity of the optic nerve stump, the reactivity of the parts of the brain irradiated, nor the sensitivity of the skin receptors. In the cases considered, the cause of x-ray phosphene was irradiation of the retina of the nomnal eye by scattered x rays. The averaged coefficient of scatter was about 2%. On irradiation of the occiptal regions of the brain in subjects with normal eyes at a dose of about 150 mr, one subject perceived a flash of light. In this case, the absorbed dose for the occipital regions of the brain was about 40 mrad. The reason for this phenomenon must be explored. Stimulation of the cerebral formations (after atrophic changes in the visual tract and cortex) by x radia tion with a dose of up to 3 r, did not cause visual sensations. With the disposition of the beam, the absorbed dose for the chiasma was about 1 rad and for the occipital regions about 0.2 rad. In the study of threshold visual sensation and their causes on x irradiation of various regions of the head, it is important to apply defined doses of radiation. Scatter of the x rays in the head must be taken into consideration. (auth)« less
NASA Astrophysics Data System (ADS)
Yusof, Mohd Fahmi Mohd; Hamid, Puteri Nor Khatijah Abdul; Bauk, Sabar; Hashim, Rokiah; Tajuddin, Abdul Aziz
2015-04-01
Plug density phantoms were constructed in accordance to CT density phantom model 062M CIRS using binderless, pre-treated and tannin-based Rhizophora Spp. particleboards. The Rhizophora Spp. plug phantoms were scanned along with the CT density phantom using Siemens Somatom Definition AS CT scanner at three CT energies of 80, 120 and 140 kVp. 15 slices of images with 1.0 mm thickness each were taken from the central axis of CT density phantom for CT number and CT density profile analysis. The values were compared to water substitute plug phantom from the CT density phantom. The tannin-based Rhizophora Spp. gave the nearest value of CT number to water substitute at 80 and 120 kVp CT energies with χ2 value of 0.011 and 0.014 respectively while the binderless Rhizphora Spp. gave the nearest CT number to water substitute at 140 kVp CT energy with χ2 value of 0.023. The tannin-based Rhizophora Spp. gave the nearest CT density profile to water substitute at all CT energies. This study indicated the suitability of Rhizophora Spp. particleboard as phantom material for the use in CT imaging studies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yusof, Mohd Fahmi Mohd, E-mail: mfahmi@usm.my; Hamid, Puteri Nor Khatijah Abdul; Tajuddin, Abdul Aziz
2015-04-29
Plug density phantoms were constructed in accordance to CT density phantom model 062M CIRS using binderless, pre-treated and tannin-based Rhizophora Spp. particleboards. The Rhizophora Spp. plug phantoms were scanned along with the CT density phantom using Siemens Somatom Definition AS CT scanner at three CT energies of 80, 120 and 140 kVp. 15 slices of images with 1.0 mm thickness each were taken from the central axis of CT density phantom for CT number and CT density profile analysis. The values were compared to water substitute plug phantom from the CT density phantom. The tannin-based Rhizophora Spp. gave the nearest valuemore » of CT number to water substitute at 80 and 120 kVp CT energies with χ{sup 2} value of 0.011 and 0.014 respectively while the binderless Rhizphora Spp. gave the nearest CT number to water substitute at 140 kVp CT energy with χ{sup 2} value of 0.023. The tannin-based Rhizophora Spp. gave the nearest CT density profile to water substitute at all CT energies. This study indicated the suitability of Rhizophora Spp. particleboard as phantom material for the use in CT imaging studies.« less
Flash Point Performance Evaluation
2014-03-01
ACRONYMS AND ABBREVIATIONS Acronym Definition ASTM ASTM International, consensus standards and specifications B20 Biodiesel containing 20% FAME...HRJ-1 is a sample of HEFA SPK [10] that is used to blend semi-synthetic jet fuel. The B20-1 is a sample of a 20% biodiesel blend [20]. The US Army...Standard Specification for Diesel Fuel Oil, Biodiesel Blend (B6 to B20), ASTM International, W. Conshohocken, PA 21. MIL-DTL-25576E the Detail
Alencar, Estefania Queiroga de Santana e; Nobrega, Maria de Lourdes Martins; Dametto, Fabio Roberto; dos Santos, Patrícia Bittencourt Dutra; Pinheiro, Fabio Henrique de Sá Leitão
2016-01-01
ABSTRACT Objective: This study aimed to evaluate the effectiveness of two methods of visual magnification (operating microscope and light head magnifying glass) for removal of composite flash around orthodontic metal brackets. Material and Methods: Brackets were bonded in the center of the clinical crown of sixty well-preserved human premolars. Half of the sample was bonded with conventional Transbond XT (3M Unitek TM, USA), whereas the other half was bonded with Transbond TM Plus Color Change (3M Unitek TM, USA). For each type of composite, the choice of method to remove the flash was determined by randomly distributing the teeth into the following subgroups: A (removal by naked eye, n = 10), B (removal with the aid of light head magnifying glass, under 4x magnification, n = 10), and C (removal with the aid of an operating microscope, under 40x magnification, n = 10). Brackets were debonded and teeth taken to a scanning electron microscope (SS-x-550, Shimadzu, Japan) for visualization of their buccal surface. Quantification of composite flash was performed with Image Pro Plus software, and values were compared by Kruskal-Wallis test and Dunn’s post-hoc test at 5% significance level. Results: Removal of pigmented orthodontic adhesive with the aid of light head magnifying glass proved, in general, to be advantageous in comparison to all other methods. Conclusion: There was no advantage in using Transbond TM Plus Color Change alone. Further studies are necessary to draw a more definitive conclusion in regards to the benefits of using an operating microscope. PMID:28125139
NASA Astrophysics Data System (ADS)
Robins, Marthony; Solomon, Justin; Sahbaee, Pooyan; Sedlmair, Martin; Choudhury, Kingshuk Roy; Pezeshk, Aria; Sahiner, Berkman; Samei, Ehsan
2017-09-01
Virtual nodule insertion paves the way towards the development of standardized databases of hybrid CT images with known lesions. The purpose of this study was to assess three methods (an established and two newly developed techniques) for inserting virtual lung nodules into CT images. Assessment was done by comparing virtual nodule volume and shape to the CT-derived volume and shape of synthetic nodules. 24 synthetic nodules (three sizes, four morphologies, two repeats) were physically inserted into the lung cavity of an anthropomorphic chest phantom (KYOTO KAGAKU). The phantom was imaged with and without nodules on a commercial CT scanner (SOMATOM Definition Flash, Siemens) using a standard thoracic CT protocol at two dose levels (1.4 and 22 mGy CTDIvol). Raw projection data were saved and reconstructed with filtered back-projection and sinogram affirmed iterative reconstruction (SAFIRE, strength 5) at 0.6 mm slice thickness. Corresponding 3D idealized, virtual nodule models were co-registered with the CT images to determine each nodule’s location and orientation. Virtual nodules were voxelized, partial volume corrected, and inserted into nodule-free CT data (accounting for system imaging physics) using two methods: projection-based Technique A, and image-based Technique B. Also a third Technique C based on cropping a region of interest from the acquired image of the real nodule and blending it into the nodule-free image was tested. Nodule volumes were measured using a commercial segmentation tool (iNtuition, TeraRecon, Inc.) and deformation was assessed using the Hausdorff distance. Nodule volumes and deformations were compared between the idealized, CT-derived and virtual nodules using a linear mixed effects regression model which utilized the mean, standard deviation, and coefficient of variation (Mea{{n}RHD} , ST{{D}RHD} and C{{V}RHD}{) }~ of the regional Hausdorff distance. Overall, there was a close concordance between the volumes of the CT-derived and virtual nodules. Percent differences between them were less than 3% for all insertion techniques and were not statistically significant in most cases. Correlation coefficient values were greater than 0.97. The deformation according to the Hausdorff distance was also similar between the CT-derived and virtual nodules with minimal statistical significance in the (C{{V}RHD} ) for Techniques A, B, and C. This study shows that both projection-based and image-based nodule insertion techniques yield realistic nodule renderings with statistical similarity to the synthetic nodules with respect to nodule volume and deformation. These techniques could be used to create a database of hybrid CT images containing nodules of known size, location and morphology.
Robins, Marthony; Solomon, Justin; Sahbaee, Pooyan; Sedlmair, Martin; Choudhury, Kingshuk Roy; Pezeshk, Aria; Sahiner, Berkman; Samei, Ehsan
2017-01-01
Virtual nodule insertion paves the way towards the development of standardized databases of hybrid CT images with known lesions. The purpose of this study was to assess three methods (an established and two newly developed techniques) for inserting virtual lung nodules into CT images. Assessment was done by comparing virtual nodule volume and shape to the CT-derived volume and shape of synthetic nodules. 24 synthetic nodules (three sizes, four morphologies, two repeats) were physically inserted into the lung cavity of an anthropomorphic chest phantom (KYOTO KAGAKU). The phantom was imaged with and without nodules on a commercial CT scanner (SOMATOM Definition Flash, Siemens) using a standard thoracic CT protocol at two dose levels (1.4 and 22 mGy CTDIvol). Raw projection data were saved and reconstructed with filtered back-projection and sinogram affirmed iterative reconstruction (SAFIRE, strength 5) at 0.6 mm slice thickness. Corresponding 3D idealized, virtual nodule models were co-registered with the CT images to determine each nodule’s location and orientation. Virtual nodules were voxelized, partial volume corrected, and inserted into nodule-free CT data (accounting for system imaging physics) using two methods: projection-based Technique A, and image-based Technique B. Also a third Technique C based on cropping a region of interest from the acquired image of the real nodule and blending it into the nodule-free image was tested. Nodule volumes were measured using a commercial segmentation tool (iNtuition, TeraRecon, Inc.) and deformation was assessed using the Hausdorff distance. Nodule volumes and deformations were compared between the idealized, CT-derived and virtual nodules using a linear mixed effects regression model which utilized the mean, standard deviation, and coefficient of variation (MeanRHD, and STDRHD CVRHD) of the regional Hausdorff distance. Overall, there was a close concordance between the volumes of the CT-derived and virtual nodules. Percent differences between them were less than 3% for all insertion techniques and were not statistically significant in most cases. Correlation coefficient values were greater than 0.97. The deformation according to the Hausdorff distance was also similar between the CT-derived and virtual nodules with minimal statistical significance in the (CVRHD) for Techniques A, B, and C. This study shows that both projection-based and image-based nodule insertion techniques yield realistic nodule renderings with statistical similarity to the synthetic nodules with respect to nodule volume and deformation. These techniques could be used to create a database of hybrid CT images containing nodules of known size, location and morphology. PMID:28786399
Convolution-based estimation of organ dose in tube current modulated CT
NASA Astrophysics Data System (ADS)
Tian, Xiaoyu; Segars, W. Paul; Dixon, Robert L.; Samei, Ehsan
2016-05-01
Estimating organ dose for clinical patients requires accurate modeling of the patient anatomy and the dose field of the CT exam. The modeling of patient anatomy can be achieved using a library of representative computational phantoms (Samei et al 2014 Pediatr. Radiol. 44 460-7). The modeling of the dose field can be challenging for CT exams performed with a tube current modulation (TCM) technique. The purpose of this work was to effectively model the dose field for TCM exams using a convolution-based method. A framework was further proposed for prospective and retrospective organ dose estimation in clinical practice. The study included 60 adult patients (age range: 18-70 years, weight range: 60-180 kg). Patient-specific computational phantoms were generated based on patient CT image datasets. A previously validated Monte Carlo simulation program was used to model a clinical CT scanner (SOMATOM Definition Flash, Siemens Healthcare, Forchheim, Germany). A practical strategy was developed to achieve real-time organ dose estimation for a given clinical patient. CTDIvol-normalized organ dose coefficients ({{h}\\text{Organ}} ) under constant tube current were estimated and modeled as a function of patient size. Each clinical patient in the library was optimally matched to another computational phantom to obtain a representation of organ location/distribution. The patient organ distribution was convolved with a dose distribution profile to generate {{≤ft(\\text{CTD}{{\\text{I}}\\text{vol}}\\right)}\\text{organ, \\text{convolution}}} values that quantified the regional dose field for each organ. The organ dose was estimated by multiplying {{≤ft(\\text{CTD}{{\\text{I}}\\text{vol}}\\right)}\\text{organ, \\text{convolution}}} with the organ dose coefficients ({{h}\\text{Organ}} ). To validate the accuracy of this dose estimation technique, the organ dose of the original clinical patient was estimated using Monte Carlo program with TCM profiles explicitly modeled. The discrepancy between the estimated organ dose and dose simulated using TCM Monte Carlo program was quantified. We further compared the convolution-based organ dose estimation method with two other strategies with different approaches of quantifying the irradiation field. The proposed convolution-based estimation method showed good accuracy with the organ dose simulated using the TCM Monte Carlo simulation. The average percentage error (normalized by CTDIvol) was generally within 10% across all organs and modulation profiles, except for organs located in the pelvic and shoulder regions. This study developed an improved method that accurately quantifies the irradiation field under TCM scans. The results suggested that organ dose could be estimated in real-time both prospectively (with the localizer information only) and retrospectively (with acquired CT data).
2010-04-29
magnitude greater than today’s high-definition video coding standards. Moreover, the micromirror devices of maskless lithography are smaller than those...be found in the literature [33]. In this architecture, the optical source flashes on a writer system, which consists of a micromirror array and a...the writer system. Due to the physical dimension constraints of the micromirror array and writer system, an entire wafer can be written in a few
Development of a flash, bang, and smoke simulation of a shell burst
NASA Technical Reports Server (NTRS)
Williamson, F. R.; Kinney, J. F.; Wallace, T. V.
1982-01-01
A large number of experiments (cue test firings) were performed in the definition of the cue concepts and packaging configurations. A total of 344 of these experiments were recorded with instrumentation photography to allow a quantitative analysis of the smoke cloud to be made as a function of time. These analyses were predominantly made using a short test site. Supplementary long range visibility tests were conducted to insure the required 3 kilometer visibility of the smoke signature.
An entropy decision approach in flash flood warning: rainfall thresholds definition
NASA Astrophysics Data System (ADS)
Montesarchio, V.; Napolitano, F.; Ridolfi, E.
2009-09-01
Flash floods events are floods characterised by very rapid response of the basins to the storms, and often they involve loss of life and damage to common and private properties. Due to the specific space-time scale of this kind of flood, generally only a short lead time is available for triggering civil protection measures. Thresholds values specify the precipitation amount for a given duration that generates a critical discharge in a given cross section. The overcoming of these values could produce a critical situation in river sites exposed to alluvial risk, so it is possible to compare directly the observed or forecasted precipitation with critical reference values, without running on line real time forecasting systems. This study is focused on the Mignone River basin, located in Central Italy. The critical rainfall threshold values are evaluated minimising an utility function based on the informative entropy concept. The study concludes with a system performance analysis, in terms of correctly issued warning, false alarms and missed alarms.
Using radar-derived parameters to forecast lightning cessation for nonisolated storms
NASA Astrophysics Data System (ADS)
Davey, Matthew J.; Fuelberg, Henry E.
2017-03-01
Lightning impacts operations at the Kennedy Space Center (KSC) and other outdoor venues leading to injuries, inconvenience, and detrimental economic impacts. This research focuses on cases of "nonisolated" lightning which we define as one cell whose flashes have ceased although it is still embedded in weak composite reflectivity (Z ≥ 15 dBZ) with another cell that is still producing flashes. The objective is to determine if any radar-derived parameters provide useful information about the occurrence of lightning cessation in remnant storms. The data set consists of 50 warm season (May-September) nonisolated storms near KSC during 2013. The research utilizes the National Lightning Detection Network, the second generation Lightning Detection and Ranging network, and polarized radar data. These data are merged and analyzed using the Warning Decision Support System-Integrated Information at 1 min intervals. Our approach only considers 62 parameters, most of which are related to the noninductive charging mechanism. They included the presence of graupel at various thermal altitudes, maximum reflectivity of the decaying storm at thermal altitudes, maximum connecting composite reflectivity between the decaying cell and active cell, minutes since the previous flash, and several others. Results showed that none of the parameters reliably indicated lightning cessation for even our restrictive definition of nonisolated storms. Additional research is needed before cessation can be determined operationally with the high degree of accuracy required for safety.
Why Flash Type Matters: A Statistical Analysis
NASA Astrophysics Data System (ADS)
Mecikalski, Retha M.; Bitzer, Phillip M.; Carey, Lawrence D.
2017-09-01
While the majority of research only differentiates between intracloud (IC) and cloud-to-ground (CG) flashes, there exists a third flash type, known as hybrid flashes. These flashes have extensive IC components as well as return strokes to ground but are misclassified as CG flashes in current flash type analyses due to the presence of a return stroke. In an effort to show that IC, CG, and hybrid flashes should be separately classified, the two-sample Kolmogorov-Smirnov (KS) test was applied to the flash sizes, flash initiation, and flash propagation altitudes for each of the three flash types. The KS test statistically showed that IC, CG, and hybrid flashes do not have the same parent distributions and thus should be separately classified. Separate classification of hybrid flashes will lead to improved lightning-related research, because unambiguously classified hybrid flashes occur on the same order of magnitude as CG flashes for multicellular storms.
Estimation of the weighted CTDI{sub {infinity}} for multislice CT examinations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li Xinhua; Zhang Da; Liu, Bob
2012-02-15
Purpose: The aim of this study was to examine the variations of CT dose index (CTDI) efficiencies, {epsilon}(CTDI{sub 100})=CTDI{sub 100}/CTDI{sub {infinity}}, with bowtie filters and CT scanner types. Methods: This was an extension of our previous study [Li, Zhang, and Liu, Phys. Med. Biol. 56, 5789-5803 (2011)]. A validated Monte Carlo program was used to calculate {epsilon}(CTDI{sub 100}) on a Siemens Somatom Definition scanner. The {epsilon}(CTDI{sub 100}) dependencies on tube voltages and beam widths were tested in previous studies. The influences of different bowtie filters and CT scanner types were examined in this work. The authors tested the variations ofmore » {epsilon}(CTDI{sub 100}) with bowtie filters on the Siemens Definition scanner. The authors also analyzed the published CTDI measurements of four independent studies on five scanners of four models from three manufacturers. Results: On the Siemens Definition scanner, the difference in {epsilon}(CTDI{sub W}) between using the head and body bowtie filters was 2.5% (maximum) in the CT scans of the 32-cm phantom, and 1.7% (maximum) in the CT scans of the 16-cm phantom. Compared with CTDI{sub W}, the weighted CTDI{sub {infinity}} increased by 30.5% (on average) in the 32-cm phantom, and by 20.0% (on average) in the 16-cm phantom. These results were approximately the same for 80-140 kV and 1-40 mm beam widths (4.2% maximum deviation). The differences in {epsilon}(CTDI{sub 100}) between the simulations and the direct measurements of four previous studies were 1.3%-5.0% at the center/periphery of the 16-cm/32-cm phantom (on average). Conclusions: Compared with CTDI{sub vol}, the equilibrium dose for large scan lengths is 30.5% higher in the 32-cm phantom, and is 20.0% higher in the 16-cm phantom. The relative increases are practically independent of tube voltages (80-140 kV), beam widths (up to 4 cm), and the CT scanners covered in this study.« less
Measuring hot flash phenomenonology using ambulatory prospective digital diaries
Fisher, William I.; Thurston, Rebecca C.
2016-01-01
Objective This study provides the description, protocol, and results from a novel prospective ambulatory digital hot flash phenomenon diary. Methods This study included 152 midlife women with daily hot flashes who completed an ambulatory electronic hot flash diary continuously for the waking hours of 3 consecutive days. In this diary, women recorded their hot flashes and accompanying characteristics and associations as the hot flashes occurred. Results Self-reported hot flash severity on the digital diaries indicated that the majority of hot flashes were rated as mild (41.3%) or moderate (43.7%). Severe (13.1%) and very severe (1.8%) hot flashes were less common. Hot flash bother ratings were rated as mild (43%), or moderate (33.5%), with fewer hot flashes reported bothersome (17.5%) or very bothersome (6%). The majority of hot flashes were reported as occurring on the on the face (78.9%), neck (74.7%), and chest (61.3%). Prickly skin was reported concurrently with 32% of hot flashes, 7% with anxiety and 5% with nausea. A novel finding, 38% of hot flashes were accompanied by a premonitory aura. Conclusion A prospective electronic digital hot flash diary allows for a more precise quantitation of hot flashes while overcoming many of the limitations of commonly employed retrospective questionnaires and paper diaries. Unique insights into the phenomenology, loci and associated characteristics of hot flashes were obtained using this device. The digital hot flash phenomenology diary is recommended for future ambulatory studies of hot flashes as a prospective measure of the hot flash experience. PMID:27404030
Measuring hot flash phenomenonology using ambulatory prospective digital diaries.
Fisher, William I; Thurston, Rebecca C
2016-11-01
This study provides the description, protocol, and results from a novel prospective ambulatory digital hot flash phenomenon diary. This study included 152 midlife women with daily hot flashes who completed an ambulatory electronic hot flash diary continuously for the waking hours of three consecutive days. In this diary, women recorded their hot flashes and accompanying characteristics and associations as the hot flashes occurred. Self-reported hot flash severity on the digital diaries indicated that the majority of hot flashes were rated as mild (41.3%) or moderate (43.7%). Severe (13.1%) and very severe (1.8%) hot flashes were less common. Hot flash bother ratings were rated as mild (43%), or moderate (33.5%), with fewer hot flashes reported bothersome (17.5%) or very bothersome (6%). The majority of hot flashes were reported as occurring on the face (78.9%), neck (74.7%), and chest (61.3%). Of all reported hot flashes, 32% occurred concurrently with prickly skin, 7% with anxiety, and 5% with nausea. A novel finding from the study was that 38% of hot flashes were accompanied by a premonitory aura. A prospective electronic digital hot flash diary allows for a more precise quantitation of hot flashes while overcoming many of the limitations of commonly used retrospective questionnaires and paper diaries. Unique insights into the phenomenology, loci, and associated characteristics of hot flashes were obtained using this device. The digital hot flash phenomenology diary is recommended for future ambulatory studies of hot flashes as a prospective measure of the hot flash experience.
Gibson, Carolyn; Matthews, Karen; Thurston, Rebecca
2014-01-01
Objective To examine the role of physical activity in menopausal hot flashes. Competing models conceptualize physical activity as a risk or protective factor for hot flashes. Few studies have examined this relationship prospectively using physiologic measures of hot flashes and physical activity. Design Over two 48 hour-periods, 51 participants wore a physiologic hot flash monitor and activity monitor, and reported their hot flashes in an electronic diary. Physiologic hot flashes, reported hot flashes and reported hot flashes without physiological corroboration were related to activity changes using hierarchical generalized linear modeling, adjusting for potential confounders. Setting Community. Patients Midlife women. Interventions None. Main Outcome Measures Physiologically-detected hot flashes and reported hot flashes with and without physiologic corroboration. Results Hot flash reports without physiologic corroboration were more likely after activity increases (OR 1.04, 95% CI: 1.00-1.10, p=.01), particularly among women with higher levels of depressive symptoms (interaction p=.02). No other types of hot flashes were related to physical activity. Conclusion Acute increases in physical activity were associated with increased reporting of hot flashes lacking physiologic corroboration, particularly among women with depressive symptoms. Clinicians should consider the role of symptom perception and reporting in relations between physical activity and hot flashes. PMID:24491454
Adaptive P300 based control system
Jin, Jing; Allison, Brendan Z.; Sellers, Eric W.; Brunner, Clemens; Horki, Petar; Wang, Xingyu; Neuper, Christa
2015-01-01
An adaptive P300 brain-computer interface (BCI) using a 12 × 7 matrix explored new paradigms to improve bit rate and accuracy. During online use, the system adaptively selects the number of flashes to average. Five different flash patterns were tested. The 19-flash paradigm represents the typical row/column presentation (i.e., 12 columns and 7 rows). The 9- and 14-flash A & B paradigms present all items of the 12 × 7 matrix three times using either nine or 14 flashes (instead of 19), decreasing the amount of time to present stimuli. Compared to 9-flash A, 9-flash B decreased the likelihood that neighboring items would flash when the target was not flashing, thereby reducing interference from items adjacent to targets. 14-flash A also reduced adjacent item interference and 14-flash B additionally eliminated successive (double) flashes of the same item. Results showed that accuracy and bit rate of the adaptive system were higher than the non-adaptive system. In addition, 9- and 14-flash B produced significantly higher performance than their respective A conditions. The results also show the trend that the 14-flash B paradigm was better than the 19-flash pattern for naïve users. PMID:21474877
Joffe, Hadine; White, David P.; Crawford, Sybil L.; McCurnin, Kristin E.; Economou, Nicole; Connors, Stephanie; Hall, Janet E.
2013-01-01
Objectives The impact of hot flashes on sleep is of great clinical interest, but results are inconsistent, especially when both hot flashes and sleep are measured objectively. Using objective and subjective measurements, we examined the impact of hot flashes on sleep by inducing hot flashes with a gonadotropin-releasing hormone agonist (GnRHa). Methods The GnRHa leuprolide was administered to 20 healthy premenopausal volunteers without hot flashes or sleep disturbances. Induced hot flashes were assessed objectively (skin-conductance monitor) and subjectively (daily diary) during one-month follow-up. Changes from baseline in objective (actigraphy) and subjective sleep quality (Pittsburgh Sleep Quality Index [PSQI]) were compared between women who did and did not develop objective hot flashes, and, in parallel analyses, subjective hot flashes. Results New-onset hot flashes were recorded in 14 (70%) and reported by 14 (70%) women (80% concordance). Estradiol was universally suppressed. Objective sleep efficiency worsened in women with objective hot flashes and improved in women without objective hot flashes (median decrease 2.6%, increase 4.2%, p=0.005). Subjective sleep quality worsened more in those with than without subjective hot flashes (median increase PSQI 2.5 vs. 1.0, p=0.03). Objective hot flashes were not associated with subjective sleep quality, nor were subjective symptoms linked to objective sleep measures. Conclusions This experimental model of induced hot flashes demonstrates a causal relationship between hot flashes and poor sleep quality. Objective hot flashes result in worse objective sleep efficiency, while subjective hot flashes worsen perceived sleep quality. PMID:23481119
An angle-dependent estimation of CT x-ray spectrum from rotational transmission measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, Yuan, E-mail: yuan.lin@duke.edu; Samei, Ehsan; Ramirez-Giraldo, Juan Carlos
2014-06-15
Purpose: Computed tomography (CT) performance as well as dose and image quality is directly affected by the x-ray spectrum. However, the current assessment approaches of the CT x-ray spectrum require costly measurement equipment and complicated operational procedures, and are often limited to the spectrum corresponding to the center of rotation. In order to address these limitations, the authors propose an angle-dependent estimation technique, where the incident spectra across a wide range of angular trajectories can be estimated accurately with only a single phantom and a single axial scan in the absence of the knowledge of the bowtie filter. Methods: Themore » proposed technique uses a uniform cylindrical phantom, made of ultra-high-molecular-weight polyethylene and positioned in an off-centered geometry. The projection data acquired with an axial scan have a twofold purpose. First, they serve as a reflection of the transmission measurements across different angular trajectories. Second, they are used to reconstruct the cross sectional image of the phantom, which is then utilized to compute the intersection length of each transmission measurement. With each CT detector element recording a range of transmission measurements for a single angular trajectory, the spectrum is estimated for that trajectory. A data conditioning procedure is used to combine information from hundreds of collected transmission measurements to accelerate the estimation speed, to reduce noise, and to improve estimation stability. The proposed spectral estimation technique was validated experimentally using a clinical scanner (Somatom Definition Flash, Siemens Healthcare, Germany) with spectra provided by the manufacturer serving as the comparison standard. Results obtained with the proposed technique were compared against those obtained from a second conventional transmission measurement technique with two materials (i.e., Cu and Al). After validation, the proposed technique was applied to measure spectra from the clinical system across a range of angular trajectories [−15°, 15°] and spectrum settings (80, 100, 120, 140 kVp). Results: At 140 kVp, the proposed technique was comparable to the conventional technique in terms of the mean energy difference (MED, −0.29 keV) and the normalized root mean square difference (NRMSD, 0.84%) from the comparison standard compared to 0.64 keV and 1.56%, respectively, with the conventional technique. The average absolute MEDs and NRMSDs across kVp settings and angular trajectories were less than 0.61 keV and 3.41%, respectively, which indicates a high level of estimation accuracy and stability. Conclusions: An angle-dependent estimation technique of CT x-ray spectra from rotational transmission measurements was proposed. Compared with the conventional technique, the proposed method simplifies the measurement procedures and enables incident spectral estimation for a wide range of angular trajectories. The proposed technique is suitable for rigorous research objectives as well as routine clinical quality control procedures.« less
Menopausal hot flashes: Randomness or rhythmicity
NASA Astrophysics Data System (ADS)
Kronenberg, Fredi
1991-10-01
Menopausal hot flashes are episodes of flushing, increased heart rate, skin blood flow and skin temperature, and a sensation of heat. The thermoregulatory and cardiovascular concomitants of hot flashes are associated with peaks in the levels of various hormones and neurotransmitters in the peripheral circulation. Although hot flashes affect about 75% of women, and are the primary reason that women at menopause seek medical attention, the mechanism of hot flashes is still not understood. Hot flashes vary in frequency and intensity both within and between individuals, and have been thought of as occurring randomly. Yet, some women report that their hot flashes are worse at a particular time of day or year. Initial examination of subjects' recordings of their hot flashes showed diurnal patterns of hot flash occurrence. There also seems to be a diurnal rhythm of hot flash intensity. Continuous physiological monitoring of hot flashes is facilitating the analysis of these patterns, which is revealing circadian and ultradian periodicities. The occurrence of hot flashes can be modulated by external and internal factors, including ambient temperature and fever. Rhythms of thermoregulatory and endocrine functions also may influence hot flash patterns. Examination of the interrelationships between the various systems of the body involved in hot flashes, and a multidisciplinary approach to the analysis of hot flash patterns, will aid our understanding of this complex phenomenon.
Web Delivery of Interactive Laboratories: Comparison of Three Authoring Tools
NASA Astrophysics Data System (ADS)
Silbar, Richard R.
2002-04-01
It is well-known that the more a student interacts with a subject, the better he or she will learn it. This is particularly true in technical subjects. One way to do this is to have computer-based "laboratories" in which the student manipulates objects on the screen with keyboard or mouse and then sees the outcome of those actions. One example of such a laboratory we have built, using Macromedia's Authorware, deals with addition of two vectors in the geometric approach. The problem with Authorware, however, is that, if one wants to deliver the training over the Web, that requires the download and installation of a big plug-in. Therefore, as an experiment, I built clones of the Vector Addition Laboratory using Macromedia's Director or Flash, each of which have smaller plug-ins which are often already installed in the user's browser. The Director and Flash versions are similar to (but definitely not the same as) the Authorware version. This talk goes into these differences and demonstrates the techniques used. You can view the three examples on-line at http://www.whistlesoft.com/ silbar.
An Analysis of Total Lightning Flash Rates Over Florida
NASA Astrophysics Data System (ADS)
Mazzetti, Thomas O.; Fuelberg, Henry E.
2017-12-01
Although Florida is known as the "Sunshine State", it also contains the greatest lightning flash densities in the United States. Flash density has received considerable attention in the literature, but lightning flash rate has received much less attention. We use data from the Earth Networks Total Lightning Network (ENTLN) to produce a 5 year (2010-2014) set of statistics regarding total flash rates over Florida and adjacent regions. Instead of tracking individual storms, we superimpose a 0.2° × 0.2° grid over the study region and count both cloud-to-ground (CG) and in-cloud (IC) flashes over 5 min intervals. Results show that the distribution of total flash rates is highly skewed toward small values, whereas the greatest rate is 185 flashes min-1. Greatest average annual flash rates ( 3 flashes min-1) are located near Orlando. The southernmost peninsula, North Florida, and the Florida Panhandle exhibit smaller average annual flash rates ( 1.5 flashes min-1). Large flash rates > 100 flashes min-1 can occur during any season, at any time during the 24 h period, and at any location within the domain. However, they are most likely during the afternoon and early evening in East Central Florida during the spring and summer months.
Behavioral weight loss for the management of menopausal hot flashes: a pilot study.
Thurston, Rebecca C; Ewing, Linda J; Low, Carissa A; Christie, Aimee J; Levine, Michele D
2015-01-01
Although adiposity has been considered to be protective against hot flashes, newer data suggest positive relationships between hot flashes and adiposity. No studies have been specifically designed to test whether weight loss reduces hot flashes. This pilot study aimed to evaluate the feasibility, acceptability, and initial efficacy of behavioral weight loss in reducing hot flashes. Forty overweight or obese women with hot flashes (≥ 4 hot flashes/d) were randomized to either behavioral weight loss intervention or wait-list control. Hot flashes were assessed before and after intervention via physiologic monitoring, diary, and questionnaire. Comparisons of changes in hot flashes and anthropometrics between conditions were performed via Wilcoxon tests. Study retention (83%) and intervention satisfaction (93.8%) were high. Most women (74.1%) reported that hot flash reduction was a major motivator for losing weight. Women randomized to the weight loss intervention lost more weight (-8.86 kg) than did women randomized to control (+0.23 kg; P < 0.0001). Women randomized to weight loss also showed greater reductions in questionnaire-reported hot flashes (2-wk hot flashes, -63.0) than did women in the control group (-28.0; P = 0.03)-a difference not demonstrated in other hot flash measures. Reductions in weight and hot flashes were significantly correlated (eg, r = 0.47, P = 0.006). This pilot study shows a behavioral weight loss program that is feasible, acceptable, and effective in producing weight loss among overweight or obese women with hot flashes. Findings indicate the importance of a larger study designed to test behavioral weight loss for hot flash reduction. Hot flash management could motivate women to engage in this health-promoting behavior.
Targeting an efficient target-to-target interval for P300 speller brain–computer interfaces
Sellers, Eric W.; Wang, Xingyu
2013-01-01
Longer target-to-target intervals (TTI) produce greater P300 event-related potential amplitude, which can increase brain–computer interface (BCI) classification accuracy and decrease the number of flashes needed for accurate character classification. However, longer TTIs requires more time for each trial, which will decrease the information transfer rate of BCI. In this paper, a P300 BCI using a 7 × 12 matrix explored new flash patterns (16-, 18- and 21-flash pattern) with different TTIs to assess the effects of TTI on P300 BCI performance. The new flash patterns were designed to minimize TTI, decrease repetition blindness, and examine the temporal relationship between each flash of a given stimulus by placing a minimum of one (16-flash pattern), two (18-flash pattern), or three (21-flash pattern) non-target flashes between each target flashes. Online results showed that the 16-flash pattern yielded the lowest classification accuracy among the three patterns. The results also showed that the 18-flash pattern provides a significantly higher information transfer rate (ITR) than the 21-flash pattern; both patterns provide high ITR and high accuracy for all subjects. PMID:22350331
Spatial-temporal characteristics of lightning flash size in a supercell storm
NASA Astrophysics Data System (ADS)
Zhang, Zhixiao; Zheng, Dong; Zhang, Yijun; Lu, Gaopeng
2017-11-01
The flash sizes of a supercell storm, in New Mexico on October 5, 2004, are studied using the observations from the New Mexico Lightning Mapping Array and the Albuquerque, New Mexico, Doppler radar (KABX). First, during the temporal evolution of the supercell, the mean flash size is anti-correlated with the flash rate, following a unary power function, with a correlation coefficient of - 0.87. In addition, the mean flash size is linearly correlated with the area of reflectivity > 30 dBZ at 5 km normalized by the flash rate, with a correlation coefficient of 0.88. Second, in the horizontal, flash size increases along the direction from the region near the convection zone to the adjacent forward anvil. The region of minimum flash size usually corresponds to the region of maximum flash initiation and extent density. The horizontal correspondence between the mean flash size and the flash extent density can also be fitted by a unary power function, and the correlation coefficient is > 0.5 in 50% of the radar volume scans. Furthermore, the quality of fit is positively correlated to the convective intensity. Third, in the vertical direction, the height of the maximum flash initiation density is close to the height of maximum flash extent density, but corresponds to the height where the mean flash size is relatively small. In the discussion, the distribution of the small and dense charge regions when and where convection is vigorous in the storm, is deduced to be responsible for the relationship that flash size is temporally and spatially anti-correlated with flash rate and density, and the convective intensity.
Flash memory management system and method utilizing multiple block list windows
NASA Technical Reports Server (NTRS)
Chow, James (Inventor); Gender, Thomas K. (Inventor)
2005-01-01
The present invention provides a flash memory management system and method with increased performance. The flash memory management system provides the ability to efficiently manage and allocate flash memory use in a way that improves reliability and longevity, while maintaining good performance levels. The flash memory management system includes a free block mechanism, a disk maintenance mechanism, and a bad block detection mechanism. The free block mechanism provides efficient sorting of free blocks to facilitate selecting low use blocks for writing. The disk maintenance mechanism provides for the ability to efficiently clean flash memory blocks during processor idle times. The bad block detection mechanism provides the ability to better detect when a block of flash memory is likely to go bad. The flash status mechanism stores information in fast access memory that describes the content and status of the data in the flash disk. The new bank detection mechanism provides the ability to automatically detect when new banks of flash memory are added to the system. Together, these mechanisms provide a flash memory management system that can improve the operational efficiency of systems that utilize flash memory.
Perceived control and hot flashes in treatment-seeking breast cancer survivors and menopausal women.
Carpenter, Janet S; Wu, Jingwei; Burns, Debra S; Yu, Menggang
2012-01-01
Lower perceived control over hot flashes has been linked to fewer coping strategies, more catastrophizing, and greater hot flash severity and distress in midlife women, yet this important concept has not yet been studied in breast cancer survivors. The aim of this study was to explore perceived control over hot flashes and hot flashes in breast cancer survivors compared with midlife women without cancer. Ninety-nine survivors and 138 midlife women completed questionnaires and a prospective, electronic hot flash diary. All data were collected at a baseline assessment before randomization in a behavioral intervention study. Both groups had moderate perceived control over hot flashes. Control was not significantly related to hot flash frequency but was significantly related to hot flash severity, bother, and interference in both groups. A significantly stronger association between control and hot flash interference was found for survivors than for midlife women. Survivors using hot flash treatments perceived less control than did survivors not using hot flash treatments, whereas the opposite was true in midlife women. Findings extend our knowledge of perceived control over hot flashes in both survivors and midlife women. Findings emphasize the importance of continued menopausal symptom assessment and management, support the importance of continuing nursing care even for survivors who are already using hot flash treatment, and suggest that nursing interventions aimed at improving perceived control over hot flashes may be more helpful for survivors than for midlife women.
NASA Astrophysics Data System (ADS)
Teale, N. G.; Quiring, S. M.
2015-12-01
Understanding flash flooding is important in unfiltered watersheds, such as portions of the New York City water supply system (NYCWSS), as water quality is degraded by turbidity associated with flooding. To further understand flash flooding in watersheds of the NYCWSS, synoptic-scale atmospheric conditions most frequently associated with flash flooding between 1987 and 2013 were examined. Flash floods were identified during this time period using USGS 15-minute discharge data at the Esopus Creek near Allaben, NY and Neversink River at Claryville, NY gauges. Overall, 25 flash floods were detected, occurring over 17 separate flash flood days. These flash flood days were compared to the days on which flash flood warnings encompassing the study area was issued by the National Weather Service. The success rate for which the flash flood warnings for Ulster County coincided with flash flood in the study watershed was 0.09, demonstrating the highly localized nature of flash flooding in the Catskill Mountain region. The synoptic-scale atmospheric patterns influencing the study area were characterized by a principal component analysis and k-means clustering of NCEP/NCAR 500 mb geopotential height reanalysis data. This procedure was executed in Spatial Synoptic Typer Tools 4.0. While 17 unique synoptic patterns were identified, only 3 types were strongly associated with flash flooding events. A strong southwesterly flow suggesting advection of moisture from the Atlantic Ocean and Gulf of Mexico is shown in composites of these 3 types. This multiscalar study thereby links flash flooding in the NYCWSS with synoptic-scale atmospheric circulation.Understanding flash flooding is important in unfiltered watersheds, such as portions of the New York City water supply system (NYCWSS), as water quality is degraded by turbidity associated with flooding. To further understand flash flooding in watersheds of the NYCWSS, synoptic-scale atmospheric conditions most frequently associated with flash flooding between 1987 and 2013 were examined. Flash floods were identified during this time period using USGS 15-minute discharge data at the Esopus Creek near Allaben, NY and Neversink River at Claryville, NY gauges. Overall, 25 flash floods were detected, occurring over 17 separate flash flood days. These flash flood days were compared to the days on which flash flood warnings encompassing the study area was issued by the National Weather Service. The success rate for which the flash flood warnings for Ulster County coincided with flash flood in the study watershed was 0.09, demonstrating the highly localized nature of flash flooding in the Catskill Mountain region. The synoptic-scale atmospheric patterns influencing the study area were characterized by a principal component analysis and k-means clustering of NCEP/NCAR 500 mb geopotential height reanalysis data. This procedure was executed in Spatial Synoptic Typer Tools 4.0. While 17 unique synoptic patterns were identified, only 3 types were strongly associated with flash flooding events. A strong southwesterly flow suggesting advection of moisture from the Atlantic Ocean and Gulf of Mexico is shown in composites of these 3 types. This multiscalar study thereby links flash flooding in the NYCWSS with synoptic-scale atmospheric circulation.
Hot Flashes and Quality of Life Among Breast Cancer Patients
2006-08-01
hot flashes, 40.7% report at baseline, having used HRT and 26.8% used exercise to control hot flashes. The 12-month data indicates that 26.5% of the...entire sample who are experiencing hot flashes, tried or are using some form of HRT to control hot flashes with exercise still the most frequently...used approach to manage hot flashes with 44.2% of sample currently exercising . 15. SUBJECT TERMS Breast Cancer, Hot Flashes, Quality of Life
Physiologically assessed hot flashes and endothelial function among midlife women.
Thurston, Rebecca C; Chang, Yuefang; Barinas-Mitchell, Emma; Jennings, J Richard; von Känel, Roland; Landsittel, Doug P; Matthews, Karen A
2017-08-01
Hot flashes are experienced by most midlife women. Emerging data indicate that they may be associated with endothelial dysfunction. No studies have tested whether hot flashes are associated with endothelial function using physiologic measures of hot flashes. We tested whether physiologically assessed hot flashes were associated with poorer endothelial function. We also considered whether age modified associations. Two hundred seventy-two nonsmoking women reporting either daily hot flashes or no hot flashes, aged 40 to 60 years, and free of clinical cardiovascular disease, underwent ambulatory physiologic hot flash and diary hot flash monitoring; a blood draw; and ultrasound measurement of brachial artery flow-mediated dilation to assess endothelial function. Associations between hot flashes and flow-mediated dilation were tested in linear regression models controlling for lumen diameter, demographics, cardiovascular disease risk factors, and estradiol. In multivariable models incorporating cardiovascular disease risk factors, significant interactions by age (P < 0.05) indicated that among the younger tertile of women in the sample (age 40-53 years), the presence of hot flashes (beta [standard error] = -2.07 [0.79], P = 0.01), and more frequent physiologic hot flashes (for each hot flash: beta [standard error] = -0.10 [0.05], P = 0.03, multivariable) were associated with lower flow-mediated dilation. Associations were not accounted for by estradiol. Associations were not observed among the older women (age 54-60 years) or for self-reported hot flash frequency, severity, or bother. Among the younger women, hot flashes explained more variance in flow-mediated dilation than standard cardiovascular disease risk factors or estradiol. Among younger midlife women, frequent hot flashes were associated with poorer endothelial function and may provide information about women's vascular status beyond cardiovascular disease risk factors and estradiol.
Menopausal Hot Flashes and Carotid Intima Media Thickness Among Midlife Women.
Thurston, Rebecca C; Chang, Yuefang; Barinas-Mitchell, Emma; Jennings, J Richard; Landsittel, Doug P; Santoro, Nanette; von Känel, Roland; Matthews, Karen A
2016-12-01
There has been a longstanding interest in the role of menopause and its correlates in the development of cardiovascular disease (CVD) in women. Menopausal hot flashes are experienced by most midlife women; emerging data link hot flashes to CVD risk indicators. We tested whether hot flashes, measured via state-of-the-art physiologic methods, were associated with greater subclinical atherosclerosis as assessed by carotid ultrasound. We considered the role of CVD risk factors and estradiol concentrations in these associations. A total of 295 nonsmoking women free of clinical CVD underwent ambulatory physiologic hot flash assessments; a blood draw; and carotid ultrasound measurement of intima media thickness and plaque. Associations between hot flashes and subclinical atherosclerosis were tested in regression models controlling for CVD risk factors and estradiol. More frequent physiologic hot flashes were associated with higher carotid intima media thickness (for each additional hot flash: β [SE]=0.004 [0.001]; P=0.0001; reported hot flash: β [SE]=0.008 [0.002]; P=0.002, multivariable) and plaque (eg, for each additional hot flash, odds ratio [95% confidence interval] plaque index ≥2=1.07 [1.003-1.14]; P=0.04, relative to no plaque, multivariable] among women reporting daily hot flashes; associations were not accounted for by CVD risk factors or by estradiol. Among women reporting hot flashes, hot flashes accounted for more variance in intima media thickness than most CVD risk factors. Among women reporting daily hot flashes, frequent hot flashes may provide information about a woman's vascular status beyond standard CVD risk factors and estradiol. Frequent hot flashes may mark a vulnerable vascular phenotype among midlife women. © 2016 American Heart Association, Inc.
Menopausal Hot Flashes and Carotid Intima Media Thickness among Midlife Women
Thurston, Rebecca C.; Chang, Yuefang; Barinas-Mitchell, Emma; Jennings, J. Richard; Landsittel, Doug P.; Santoro, Nanette; von Känel, Roland; Matthews, Karen A.
2016-01-01
Background and Purpose There has been a longstanding interest in the role of menopause and its correlates in the development of cardiovascular disease (CVD) in women. Menopausal hot flashes are experienced by most midlife women; emerging data link hot flashes to CVD risk indicators. We tested whether hot flashes, measured via state-of-the-art physiologic methods, were associated with greater subclinical atherosclerosis as assessed by carotid ultrasound. We considered the role of CVD risk factors and estradiol concentrations in these associations. Methods 295 nonsmoking women free of clinical CVD underwent ambulatory physiologic hot flash assessments; a blood draw; and carotid ultrasound measurement of IMT and plaque. Associations between hot flashes and subclinical atherosclerosis were tested in regression models controlling for CVD risk factors and estradiol. Results More frequent physiologic hot flashes were associated with higher carotid intima media thickness [IMT; for each additional hot flash: beta (standard error)=.004(.001), p=.0001; reported hot flash: beta (standard error)=.008(.002), p=.002, multivariable] and plaque [e.g., for each additional hot flash, odds ratio (95% confidence interval) plaque index ≥2=1.07(1.003–1.14, p=.04), relative to no plaque, multivariable] among women reporting daily hot flashes; associations were not accounted for by CVD risk factors or by estradiol. Among women reporting hot flashes, hot flashes accounted for more variance in IMT than most CVD risk factors. Conclusions Among women reporting daily hot flashes, frequent hot flashes may provide information about a woman’s vascular status beyond standard CVD risk factors and estradiol. Frequent hot flashes may mark a vulnerable vascular phenotype among midlife women. PMID:27834746
Behavioral Weight Loss for the Management of Menopausal Hot Flashes: A Pilot Study
Thurston, Rebecca C.; Ewing, Linda J.; Low, Carissa A.; Christie, Aimee J.; Levine, Michele D.
2014-01-01
Objective Although adiposity has been considered protective against hot flashes, newer data suggest positive relations between flashes and adiposity. No studies have been specifically designed to test whether weight loss reduces hot flashes. This pilot study aimed to evaluate the feasibility, acceptability, and initial efficacy of behavioral weight loss to reduce hot flashes. Methods Forty overweight/obese women with hot flashes (≥4/day) were randomized to a behavioral weight loss intervention or to wait list control. Hot flashes were assessed pre- and post-intervention via physiologic monitor, diary, and questionnaire. Comparisons of changes in hot flashes and anthropometrics between conditions were tested via Wilcoxon tests. Results Study retention (83%) and intervention satisfaction (93.8%) were high. Most women (74.1%) reported that hot flash reduction was a main motivator to lose weight. Women randomized to the weight loss intervention lost more weight (-8.86 kg) than did women randomized to control (+0.23 kg, p<.0001). Women randomized to weight loss also showed greater reductions in questionnaire-reported hot flashes (2-week hot flashes: −63.0) than did women in the control (−28.0, p=.03), a difference not demonstrated in other hot flash measures. Reductions in weight and hot flashes were significantly correlated (e.g., r=.47, p=.006). Conclusions This pilot study showed a behavioral weight loss program to be feasible, acceptable, and effective in producing weight loss among overweight/obese women with hot flashes. Findings indicate the importance of a larger study designed to test behavioral weight loss for hot flash reduction. Hot flash management could motivate women to engage in this health-promoting behavior. PMID:24977456
Karst flash floods: an example from the Dinaric karst (Croatia)
NASA Astrophysics Data System (ADS)
Bonacci, O.; Ljubenkov, I.; Roje-Bonacci, T.
2006-03-01
Flash floods constitute one of the deadliest and costliest natural disasters worldwide. This paper explains the karst flash flood phenomenon, which represents a special kind of flash flood. As the majority of flash floods karst flash floods are caused by intensive short-term precipitation in an area whose surface rarely exceeds a few square kilometres. The characteristics of all flash floods are their short duration, small areal extent, high flood peaks and rapid flows, and heavy loss of life and property. Karst flash floods have specific characteristics due to special conditions for water circulation, which exist in karst terrains. During karst flash floods a sudden rise of groundwater levels occurs, which causes the appearance of numerous, unexpected, abundant and temporary karst springs. This paper presents in detail an example of a karst flash flood in the Marina bay (Dinaric karst region of Croatia), which occurred in December 2004.
A Comprehensive Study on Energy Efficiency and Performance of Flash-based SSD
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, Seon-Yeon; Kim, Youngjae; Urgaonkar, Bhuvan
2011-01-01
Use of flash memory as a storage medium is becoming popular in diverse computing environments. However, because of differences in interface, flash memory requires a hard-disk-emulation layer, called FTL (flash translation layer). Although the FTL enables flash memory storages to replace conventional hard disks, it induces significant computational and space overhead. Despite the low power consumption of flash memory, this overhead leads to significant power consumption in an overall storage system. In this paper, we analyze the characteristics of flash-based storage devices from the viewpoint of power consumption and energy efficiency by using various methodologies. First, we utilize simulation tomore » investigate the interior operation of flash-based storage of flash-based storages. Subsequently, we measure the performance and energy efficiency of commodity flash-based SSDs by using microbenchmarks to identify the block-device level characteristics and macrobenchmarks to reveal their filesystem level characteristics.« less
Multi- and unisensory visual flash illusions.
Courtney, Jon R; Motes, Michael A; Hubbard, Timothy L
2007-01-01
The role of stimulus structure in multisensory and unisensory interactions was examined. When a flash (17 ms) was accompanied by multiple tones (each 7 ms, SOA < or =100 ms) multiple flashes were reported, and this effect has been suggested to reflect the role of stimulus continuity in multisensory interactions. In experiments 1 and 2 we examined if stimulus continuity would affect concurrently presented stimuli. When a relatively longer flash (317 ms) was accompanied by multiple tones (each 7 ms), observers reported perceiving multiple flashes. In experiment 3 we tested whether a flash presented near fixation would induce an illusory flash further in the periphery. One flash (17 ms) presented 5 degrees below fixation was reported as multiple flashes if presented with two flashes (each 17 ms, SOA =100 ms) 2 degrees above fixation. The extent to which these data support a phenomenological continuity principle and whether this principle applies to unisensory perception is discussed.
Fetterman, J Gregor; Killeen, P Richard
2011-09-01
Pigeons pecked on three keys, responses to one of which could be reinforced after 3 flashes of the houselight, to a second key after 6, and to a third key after 12. The flashes were arranged according to variable-interval schedules. Response allocation among the keys was a function of the number of flashes. When flashes were omitted, transitions occurred very late. Increasing flash duration produced a leftward shift in the transitions along a number axis. Increasing reinforcement probability produced a leftward shift, and decreasing reinforcement probability produced a rightward shift. Intermixing different flash rates within sessions separated allocations: Faster flash rates shifted the functions sooner in real time, but later in terms of flash count, and conversely for slower flash rates. A model of control by fading memories of number and time was proposed.
Flash fire propensity of materials
NASA Technical Reports Server (NTRS)
Hilado, C. J.; Cumming, H. J.
1977-01-01
Flash fire test results on 86 materials, evaluated using the USF flash fire screening test, are presented. The materials which appear least prone to flash fires are PVC, polyphenylene oxide and sulfide, and polyether and polyaryl sulfone; these did not produce flash fires under these particular test conditions. The principal value of these screening tests at the present time is in identifying materials which appear prone to flash fires, and in identifying which formulations of a generic material are more or less prone to flash fires.
Sievert, L L; Begum, K; Sharmeen, T; Murphy, L; Whitcomb, B W; Chowdhury, O; Muttukrishna, S; Bentley, G R
2016-12-01
To examine hot flashes in relation to climate and activity patterns, and to compare subjective and objective hot flashes among Bangladeshi immigrants to London, their white London neighbors, and women still living in their community of origin, Sylhet, Bangladesh ("sedentees"). Ninety-five women, aged 40-55, wore the Biolog ambulatory hot flash monitor. Objective measurements and subjective hot flash reports were examined in relation to demographic, reproductive, anthropometric, and lifestyle variables; temperature and humidity at 12:00 and 18:00; and time spent on housework and cooking. Concordance of objective and subjective hot flashes was assessed by Kappa statistics and by sensitivity of hot flash classification. During the study period, Bangladeshi sedentees reported more subjective hot flashes (p < .05), but there was no difference in number of objective hot flashes. White Londoners were more likely to describe hot flashes on their face and neck compared to Bangladeshis (p < .05). Sedentees were more likely to describe hot flashes on their feet (p < .05). Postmenopausal status, increasing parity, and high levels of housework were significant determinants of subjective hot flashes, while ambient temperature and humidity were not. Measures of subjective/objective concordance were low but similar across groups (10-20%). The proportion of objective hot flashes that were also self-reported was lowest among immigrants. Hot flashes were not associated with warmer temperatures, but were associated with housework and with site-specific patterns of cooking. The number of objective hot flash measures did not differ, but differences in subjective experience suggest the influence of culture. © 2016 Wiley Periodicals, Inc.
Phenomenology of the sound-induced flash illusion.
Abadi, Richard V; Murphy, Jonathan S
2014-07-01
Past studies, using pairings of auditory tones and visual flashes, which were static and coincident in space but variable in time, demonstrated errors in judging the temporal patterning of the visual flashes-the sound-induced flash illusion. These errors took one of the two forms: under-reporting (sound-induced fusion) or over-reporting (sound-induced fission) of the flash numbers. Our study had three objectives: to examine the robustness of both illusions and to consider the effects of stimulus set and response bias. To this end, we used an extended range of fixed spatial location flash-tone pairings, examined stimuli that were variable in space and time and measured confidence in judging flash numbers. Our results indicated that the sound-induced flash illusion is a robust percept, a finding underpinned by the confidence measures. Sound-induced fusion was found to be more robust than sound-induced fission and a most likely outcome when high numbers of flashes were incorporated within an incongruent flash-tone pairing. Conversely, sound-induced fission was the most likely outcome for the flash-tone pairing which contained two flashes. Fission was also shown to be strongly driven by stimuli confounds such as categorical boundary conditions (e.g. flash-tone pairings with ≤2 flashes) and compressed response options. These findings suggest whilst both fission and fusion are associated with 'auditory driving', the differences in the occurrence and strength of the two illusions not only reflect the separate neuronal mechanisms underlying audio and visual signal processing, but also the test conditions that have been used to investigate the sound-induced flash illusion.
How self-reported hot flashes may relate to affect, cognitive performance and sleep.
Regestein, Quentin; Friebely, Joan; Schiff, Isaac
2015-08-01
To explain the controversy about whether midlife women who self-report hot flashes have relatively increased affective symptoms, poor cognitive performance or worse sleep. Retrospective data from 88 women seeking relief from bothersome day and night hot flashes were submitted to mixed linear regression modeling to find if estimated hot flashes, as measured by Women's Health Questionnaire (WHQ) items, or diary-documented hot flashes recorded daily, were associated with each other, or with affective, cognitive or sleep measures. Subjects averaged 6.3 daytime diary-documented hot flashes and 2.4 nighttime diary-documented hot flashes per 24h. Confounder-controlled diary-documented hot flashes but not estimated hot flashes were associated with increased Leeds anxiety scores (F=4.9; t=2.8; p=0.01) and Leeds depression scores (3.4; 2.5; 0.02), decreased Stroop Color-Word test performance (9.4; 3.5; 0.001), increased subjective sleep disturbance (effect size=0.83) and increased objective sleep disturbance (effect size=0.35). Hot flash effects were small to moderate in size. Univariate but not multivariate analyses revealed that all hot flash measures were associated with all affect measures. Different measures of hot flashes associated differently with affect, cognition and sleep. Only nighttime diary-document hot flash consistently correlated with any affect measures in multivariate analyses. The use of differing measures for hot flashes, affect, cognition and sleep may account for the continually reported inconsistencies in menopause study outcomes. This problem impedes forging a consensus on whether hot flashes correlate with neuropsychological symptoms. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Rulaidi, W. E. P.; Huri, M. S. N.; Ng, K. H.
2017-05-01
One method to optimise the use of x-rays in CT and hence a reduction in patient dose is the application of automatic exposure control (AEC). This study measured the effective mAs, image noise and volume CT dose index (CTDIvol) as the result of changing the AEC index on a Siemens Somatom Definition 64 slices dual source CT scanner. The scans were performed on four phantoms of different geometries, namely the 16 and 32 cm cylindrical CTDI phantoms and two anthropomorphic phantoms, RANDO (20 cm effective diameter) and ATOM (19.8 cm effective diameter). Results showed that the effective mAs increased with increasing tube potential (kVp) and Quality Reference mAs (QRM), therefore increasing CTDIvol while reducing image noise. Meanwhile, no changes of radiation dose and image noise were observed when the pitch was increased. However, for the largest phantom (32 cm effective diameter), a constant effective mAs was found between 120 and 140 kVp. The same trend was also found with increasing QRM from 300 mAs to 400 mAs suggesting a certain limitation of the AEC has been reached. In conclusion, this study showed that AEC is affected by kVp and QRM but not by pitch selection. Further work is required to quantify the characteristics of the AEC system in relation to the mentioned parameters for better optimisation.
Jürgens, Julian H W; Schulz, Nadine; Wybranski, Christian; Seidensticker, Max; Streit, Sebastian; Brauner, Jan; Wohlgemuth, Walter A; Deuerling-Zheng, Yu; Ricke, Jens; Dudeck, Oliver
2015-02-01
The objective of this study was to compare the parameter maps of a new flat-panel detector application for time-resolved perfusion imaging in the angiography room (FD-CTP) with computed tomography perfusion (CTP) in an experimental tumor model. Twenty-four VX2 tumors were implanted into the hind legs of 12 rabbits. Three weeks later, FD-CTP (Artis zeego; Siemens) and CTP (SOMATOM Definition AS +; Siemens) were performed. The parameter maps for the FD-CTP were calculated using a prototype software, and those for the CTP were calculated with VPCT-body software on a dedicated syngo MultiModality Workplace. The parameters were compared using Pearson product-moment correlation coefficient and linear regression analysis. The Pearson product-moment correlation coefficient showed good correlation values for both the intratumoral blood volume of 0.848 (P < 0.01) and the blood flow of 0.698 (P < 0.01). The linear regression analysis of the perfusion between FD-CTP and CTP showed for the blood volume a regression equation y = 4.44x + 36.72 (P < 0.01) and for the blood flow y = 0.75x + 14.61 (P < 0.01). This preclinical study provides evidence that FD-CTP allows a time-resolved (dynamic) perfusion imaging of tumors similar to CTP, which provides the basis for clinical applications such as the assessment of tumor response to locoregional therapies directly in the angiography suite.
Susceptibility to the Flash-Beep Illusion Is Increased in Children Compared to Adults
ERIC Educational Resources Information Center
Innes-Brown, Hamish; Barutchu, Ayla; Shivdasani, Mohit N.; Crewther, David P.; Grayden, David B.; Paolini, Antonio
2011-01-01
Audio-visual integration was studied in children aged 8-17 (N = 30) and adults (N = 22) using the "flash-beep illusion" paradigm, where the presentation of two beeps causes a single flash to be perceived as two flashes ("fission" illusion), and a single beep causes two flashes to be perceived as one flash ("fusion" illusion). Children reported…
Global Patterns of Lightning Properties Derived by OTD and LIS
NASA Technical Reports Server (NTRS)
Beirle, Steffen; Koshak, W.; Blakeslee, R.; Wagner, T.
2014-01-01
The satellite instruments Optical Transient Detector (OTD) and Lightning Imaging Sensor (LIS) provide unique empirical data about the frequency of lightning flashes around the globe (OTD), and the tropics (LIS), which 5 has been used before to compile a well received global climatology of flash rate densities. Here we present a statistical analysis of various additional lightning properties derived from OTD/LIS, i.e. the number of so-called "events" and "groups" per flash, as well as 10 the mean flash duration, footprint and radiance. These normalized quantities, which can be associated with the flash "strength", show consistent spatial patterns; most strikingly, oceanic flashes show higher values than continental flashes for all properties. Over land, regions with high (Eastern US) 15 and low (India) flash strength can be clearly identified. We discuss possible causes and implications of the observed regional differences. Although a direct quantitative interpretation of the investigated flash properties is difficult, the observed spatial patterns provide valuable information for the 20 interpretation and application of climatological flash rates. Due to the systematic regional variations of physical flash characteristics, viewing conditions, and/or measurement sensitivities, parametrisations of lightning NOx based on total flash rate densities alone are probably affected by regional biases.
Characteristics of Lightning Within Electrified Snowfall Events Using Lightning Mapping Arrays
NASA Astrophysics Data System (ADS)
Schultz, Christopher J.; Lang, Timothy J.; Bruning, Eric C.; Calhoun, Kristin M.; Harkema, Sebastian; Curtis, Nathan
2018-02-01
This study examined 34 lightning flashes within four separate thundersnow events derived from lightning mapping arrays (LMAs) in northern Alabama, central Oklahoma, and Washington DC. The goals were to characterize the in-cloud component of each lightning flash, as well as the correspondence between the LMA observations and lightning data taken from national lightning networks like the National Lightning Detection Network (NLDN). Individual flashes were examined in detail to highlight several observations within the data set. The study results demonstrated that the structures of these flashes were primarily normal polarity. The mean area encompassed by this set of flashes is 375 km2, with a maximum flash extent of 2,300 km2, a minimum of 3 km2, and a median of 128 km2. An average of 2.29 NLDN flashes were recorded per LMA-derived lightning flash. A maximum of 11 NLDN flashes were recorded in association with a single LMA-derived flash on 10 January 2011. Additionally, seven of the 34 flashes in the study contain zero NLDN-identified flashes. Eleven of the 34 flashes initiated from tall human-made objects (e.g., communication towers). In at least six lightning flashes, the NLDN detected a return stroke from the cloud back to the tower and not the initial upward leader. This study also discusses lightning's interaction with the human-built environment and provides an example of lightning within heavy snowfall observed by Geostationary Operational Environmental Satellite-16's Geostationary Lightning Mapper.
Hot flashes in breast cancer survivors: Frequency, severity and impact.
Chang, Hao-Yuan; Jotwani, Aparna C; Lai, Yeur-Hur; Jensen, Mark P; Syrjala, Karen L; Fann, Jesse R; Gralow, Julie
2016-06-01
To (1) determine the frequency and severity of hot flashes, (2) examine the associations between hot flash frequency and severity and quality of life, and (3) identify the predictors of hot flash activity in breast cancer survivors. The study used a cross-sectional design and mailed survey of 253 breast cancer survivors recruited from a cancer wellness clinic. Participants provided information regarding cancer history, hot flashes, pain intensity, sleep problems, physical functioning, and psychological functioning. About half of the survivors reported at least one hot flash in the past 24 h (45%) or past week (52%). The average frequency of hot flashes was 1.9 in the past 24 h and 1.8 in the past week. Hot flash severity was usually mild or asymptomatic. However, participants with hot flashes reported significantly more sleep problems and higher pain severity than those reporting no hot flashes. Moreover, the severity of hot flashes was associated with more sleep problems, higher pain severity, and more psychological dysfunction. History of hormonal suppression therapy and younger age predicted hot flash activity in the study sample. In breast cancer survivors, hot flashes are common and are associated with unpleasant symptoms and poor quality of life. Research is needed to determine if treatments that reduce the frequency and severity of hot flashes in breast cancer survivors also result in improvements in symptoms such as sleep problems, pain, and psychological dysfunction. Copyright © 2016 Elsevier Ltd. All rights reserved.
Hot flashes in breast cancer survivors: Frequency, severity and impact
Chang, Hao-Yuan; Jotwani, Aparna C.; Lai, Yeur-Hur; Jensen, Mark P.; Syrjala, Karen L.; Fann, Jesse R.; Gralow, Julie
2018-01-01
Purposes To (1) determine the frequency and severity of hot flashes, (2) examine the associations be- tween hot flash frequency and severity and quality of life, and (3) identify the predictors of hot flash activity in breast cancer survivors. Methods The study used a cross-sectional design and mailed survey of 253 breast cancer survivors recruited from a cancer wellness clinic. Participants provided information regarding cancer history, hot flashes, pain intensity, sleep problems, physical functioning, and psychological functioning. Results About half of the survivors reported at least one hot flash in the past 24 h (45%) or past week (52%). The average frequency of hot flashes was 1.9 in the past 24 h and 1.8 in the past week. Hot flash severity was usually mild or asymptomatic. However, participants with hot flashes reported significantly more sleep problems and higher pain severity than those reporting no hot flashes. Moreover, the severity of hot flashes was associated with more sleep problems, higher pain severity, and more psychological dysfunction. History of hormonal suppression therapy and younger age predicted hot flash activity in the study sample. Conclusions In breast cancer survivors, hot flashes are common and are associated with unpleasant symptoms and poor quality of life. Research is needed to determine if treatments that reduce the frequency and severity of hot flashes in breast cancer survivors also result in improvements in symptoms such as sleep problems, pain, and psychological dysfunction. PMID:27065357
Characteristics of Lightning within Electrified Snowfall Events using Lightning Mapping Arrays.
Schultz, Christopher J; Lang, Timothy J; Bruning, Eric C; Calhoun, Kristin M; Harkema, Sebastian; Curtis, Nathan
2018-02-27
This study examined 34 lightning flashes within four separate thundersnow events derived from lightning mapping arrays (LMAs) in northern Alabama, central Oklahoma, and Washington DC. The goals were to characterize the in-cloud component of each lightning flash, as well as the correspondence between the LMA observations and lightning data taken from national lightning networks like the National Lightning Detection Network (NLDN). Individual flashes were examined in detail to highlight several observations within the dataset. The study results demonstrated that the structures of these flashes were primarily normal polarity. The mean area encompassed by this set of flashes is 375 km 2 , with a maximum flash extent of 2300 km 2 , a minimum of 3 km 2 , and a median of 128 km 2 . An average of 2.29 NLDN flashes were recorded per LMA-derived lightning flash. A maximum of 11 NLDN flashes were recorded in association with a single LMA-derived flash on 10 January 2011. Additionally, seven of the 34 flashes in the study contain zero NLDN identified flashes. Eleven of the 34 flashes initiated from tall human-made objects (e.g., communication towers). In at least six lightning flashes, the NLDN detected a return stroke from the cloud back to the tower and not the initial upward leader. This study also discusses lightning's interaction with the human built environment and provides an example of lightning within heavy snowfall observed by GOES-16's Geostationary Lightning Mapper.
FLASH2: Operation, beamlines, and photon diagnostics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Plönjes, Elke, E-mail: elke.ploenjes@desy.de; Faatz, Bart; Kuhlmann, Marion
2016-07-27
FLASH2, a major extension of the soft X-ray free-electron laser FLASH at DESY, turns FLASH into a multi-user FEL facility. A new undulator line is located in a separate accelerator tunnel and driven additionally by the FLASH linear accelerator. First lasing of FLASH2 was achieved in August 2014 with simultaneous user operation at FLASH1. The new FLASH2 experimental hall offers space for up to six experimental end stations, some of which will be installed permanently. The wide wavelength range spans from 4-60 nm and 0.8 nm in the 5{sup th} harmonic and in the future deep into the water windowmore » in the fundamental. While this is of high interest to users, it is challenging from the beamline instrumentation point of view. Online diagnostics - which are mostly pulse resolved - for beam intensity, position, wavelength, wave front, and pulse length have been to a large extent developed at FLASH(1) and have now been optimized for FLASH2. Pump-probe facilities for XUV-XUV, XUV optical and XUV-THz experiments will complete the FLASH2 user facility.« less
Real-time full-motion color Flash lidar for target detection and identification
NASA Astrophysics Data System (ADS)
Nelson, Roy; Coppock, Eric; Craig, Rex; Craner, Jeremy; Nicks, Dennis; von Niederhausern, Kurt
2015-05-01
Greatly improved understanding of areas and objects of interest can be gained when real time, full-motion Flash LiDAR is fused with inertial navigation data and multi-spectral context imagery. On its own, full-motion Flash LiDAR provides the opportunity to exploit the z dimension for improved intelligence vs. 2-D full-motion video (FMV). The intelligence value of this data is enhanced when it is combined with inertial navigation data to produce an extended, georegistered data set suitable for a variety of analysis. Further, when fused with multispectral context imagery the typical point cloud now becomes a rich 3-D scene which is intuitively obvious to the user and allows rapid cognitive analysis with little or no training. Ball Aerospace has developed and demonstrated a real-time, full-motion LIDAR system that fuses context imagery (VIS to MWIR demonstrated) and inertial navigation data in real time, and can stream these information-rich geolocated/fused 3-D scenes from an airborne platform. In addition, since the higher-resolution context camera is boresighted and frame synchronized to the LiDAR camera and the LiDAR camera is an array sensor, techniques have been developed to rapidly interpolate the LIDAR pixel values creating a point cloud that has the same resolution as the context camera, effectively creating a high definition (HD) LiDAR image. This paper presents a design overview of the Ball TotalSight™ LIDAR system along with typical results over urban and rural areas collected from both rotary and fixed-wing aircraft. We conclude with a discussion of future work.
Magnitude of the impact of hot flashes on sleep in perimenopausal women
de Zambotti, Massimiliano; Colrain, Ian M.; Javitz, Harold S.; Baker, Fiona C.
2014-01-01
Objective To quantify the impact of objectively-recorded hot flashes on objective sleep in perimenopausal women. Design Cross-sectional study. Participants underwent 1–5 laboratory-based polysomnographic recordings for a total of 63 nights, including sternal skin conductance measures, from which 222 hot flashes were identified according to established criteria. Data were analyzed with hierarchical mixed-effect models and Spearman correlations. Setting Sleep laboratory. Patients 34 perimenopausal women (Age±SD:50.4±2.7y). Intervention None. Main Outcome Measures Perceived and polysomnographic sleep measures (sleep quality, amount of wake after sleep onset and number of awakenings). Subjective (frequency and bother) and objective (frequency and amount of hot flash-associated wake time) hot flash measures. Results Women had an average of 3.5 (95%CI:2.8–4.2, range=1– 9) objective hot flashes per night. 69.4% of hot flashes were associated with an awakening. Hot flash-associated wake time per night was, on average, 16.6 min (95%CI:10.8–22.4), which accounted for 27.2% (SD 27.1) of total wakefulness per night. Hot flash-associated wake, but not frequency, was negatively associated with sleep efficiency and positively associated with wake after sleep onset. Also, self-reported wakefulness correlated with hot flash-associated wake, suggesting that women’s estimates of wakefulness are influenced by the amount of time spent awake in association with hot flashes during the night. More perceived and bothersome hot flashes correlated with more perceived wakefulness and awakenings and more objective hot flash-associated wake time and hot flash frequency. Conclusions The presence of physiological hot flashes accounts for a significant proportion of total objective wakefulness during the night in perimenopausal women. PMID:25256933
Adiposity and Hot Flashes in Midlife Women: A Modifying Role of Age
Santoro, Nanette; Matthews, Karen A.
2011-01-01
Background: The nature of the relationship between adiposity and hot flashes has been debated, but it has not been examined using physiological measures of hot flashes. We examined associations between body size/composition and physiologically assessed hot flashes among women with hot flashes. Methods: A subcohort of women in the Study of Women's Health Across the Nation (n = 52; 25 African-American and 27 non-Hispanic Caucasian; ages, 54 to 63 yr) who reported hot flashes, had their uterus and ovaries, and were not taking medications impacting hot flashes were recruited in 2008–2009. Women completed anthropometric measures [bioimpedance analysis of total percentage of body fat, body mass index (BMI), waist circumference], a blood draw (estradiol, SHBG, FSH, dehydroepiandrosterone sulfate), and 4 d of ambulatory sternal skin conductance monitoring with diary (physiological and reported hot flashes, respectively). Associations between anthropometrics and hot flashes were estimated with generalized estimating equations with covariates age, race, and anxiety. Results: Higher BMI (odds ratio, 0.97; 95% confidence interval, 0.94–0.99; P < 0.05) and waist circumference (odds ratio, 0.98; 95% confidence interval, 0.97–0.99; P < 0.01) were associated with fewer physiological hot flashes. Interactions by age (P < 0.05) indicated that inverse associations of body fat, BMI, and waist circumference with hot flashes were most apparent among the oldest women in the sample. Estradiol and SHBG reduced but did not eliminate age-related variations in relations between body size/composition and hot flashes. Conclusion: Higher adiposity was associated with fewer physiological hot flashes among older women with hot flashes. A modifying role of age must be considered in understanding the role of adiposity in hot flashes. PMID:21778220
Adiposity and hot flashes in midlife women: a modifying role of age.
Thurston, Rebecca C; Santoro, Nanette; Matthews, Karen A
2011-10-01
The nature of the relationship between adiposity and hot flashes has been debated, but it has not been examined using physiological measures of hot flashes. We examined associations between body size/composition and physiologically assessed hot flashes among women with hot flashes. A subcohort of women in the Study of Women's Health Across the Nation (n = 52; 25 African-American and 27 non-Hispanic Caucasian; ages, 54 to 63 yr) who reported hot flashes, had their uterus and ovaries, and were not taking medications impacting hot flashes were recruited in 2008-2009. Women completed anthropometric measures [bioimpedance analysis of total percentage of body fat, body mass index (BMI), waist circumference], a blood draw (estradiol, SHBG, FSH, dehydroepiandrosterone sulfate), and 4 d of ambulatory sternal skin conductance monitoring with diary (physiological and reported hot flashes, respectively). Associations between anthropometrics and hot flashes were estimated with generalized estimating equations with covariates age, race, and anxiety. Higher BMI (odds ratio, 0.97; 95% confidence interval, 0.94-0.99; P < 0.05) and waist circumference (odds ratio, 0.98; 95% confidence interval, 0.97-0.99; P < 0.01) were associated with fewer physiological hot flashes. Interactions by age (P < 0.05) indicated that inverse associations of body fat, BMI, and waist circumference with hot flashes were most apparent among the oldest women in the sample. Estradiol and SHBG reduced but did not eliminate age-related variations in relations between body size/composition and hot flashes. Higher adiposity was associated with fewer physiological hot flashes among older women with hot flashes. A modifying role of age must be considered in understanding the role of adiposity in hot flashes.
Initial Breakdown Pulse Amplitudes in Intracloud and Cloud-to-Ground Lightning Flashes
NASA Astrophysics Data System (ADS)
Marshall, T. C.; Smith, E. M.; Stolzenburg, M.; Karunarathne, S.; Siedlecki, R. D., II
2017-12-01
This study analyzes the largest initial breakdown (IB) pulse in flashes from three storms in Florida. The study was motivated in part by the possibility that IB pulses of IC flashes may cause of terrestrial gamma-ray flashes (TGFs). The range-normalized, zero-to-peak amplitude of the largest IB pulse within each flash was determined along with its altitude, duration, and occurrence time in the flash. Appropriate data were available for 40 intracloud (IC) and 32 cloud-to-ground (CG) flashes. Histograms of the magnitude of the largest IB pulse amplitude by flash type were similar, with mean (median) values of 1.49 (1.05) V/m for IC flashes and -1.35 (-0.87) V/m for CG flashes. The mean amplitude of the largest IC IB pulses are substantially smaller (roughly an order of magnitude smaller) than the few known pulse amplitudes of TGF events and TGF candidate events. The largest IB pulse in 30 IC flashes showed a weak inverse relation between pulse amplitude and altitude. Amplitude of the largest IB pulse for 25 CG flashes showed no altitude correlation. Duration of the largest IB pulse in ICs averaged twice as long as in CGs (96 μs versus 46 μs); all of the CG durations were <100 μs. Among the ICs, there is a positive relation between largest IB pulse duration and amplitude; the linear correlation coefficient is 0.385 with outliers excluded. The largest IB pulse in IC flashes typically occurred at a longer time after the first IB pulse (average 4.1 ms) than was the case in CG flashes (average 0.6 ms). In both flash types, the largest IB pulse was the first IB pulse in about 30% of the cases.
SUMO regulates proteasome-dependent degradation of FLASH/Casp8AP2
Vennemann, Astrid; Hofmann, Thomas G.
2013-01-01
FLASH/Casp8AP2 is a huge multifunctional protein involved in multiple cellular processes, reaching from death receptor signaling to regulation of histone gene transcription and histone mRNA processing. Previous work has shown that FLASH localizes to Cajal bodies and promyelocytic leukemia (PML) bodies. However, the function of its nuclear body association remains unclear. Here we demonstrate that murine FLASH is covalently modified by SUMO at Lys residue 1792. Interestingly, ectopic expression of SUMO results in proteasome-dependent degradation of FLASH. A point mutant of FLASH with a mutated SUMO acceptor lysine residue, FLASHK1792R, is resistant to SUMO-induced degradation. Finally, we show that arsenic trioxide, a drug known to potentiate SUMO modification and degradation of PML, triggers recruitment of FLASH to PML bodies and concomitant loss of FLASH protein. Our data suggest that SUMO targets FLASH for proteasome-dependent degradation, which is associated with recruitment of FLASH to PML bodies. PMID:23673342
Levine, Zachary S.; Floridi, Luciano
2017-01-01
We investigate the causal uncertainty surrounding the flash crash in the U.S. Treasury bond market on October 15, 2014, and the unresolved concern that no clear link has been identified between the start of the flash crash at 9:33 and the opening of the U.S. equity market at 9:30. We consider the contributory effect of mini flash crashes in equity markets, and find that the number of equity mini flash crashes in the three-minute window between market open and the Treasury Flash Crash was 2.6 times larger than the number experienced in any other three-minute window in the prior ten weekdays. We argue that (a) this statistically significant finding suggests that mini flash crashes in equity markets both predicted and contributed to the October 2014 U.S. Treasury Bond Flash Crash, and (b) mini-flash crashes are important phenomena with negative externalities that deserve much greater scholarly attention. PMID:29091931
PIAS1 interacts with FLASH and enhances its co-activation of c-Myb
2011-01-01
Background FLASH is a huge nuclear protein involved in various cellular functions such as apoptosis signalling, NF-κB activation, S-phase regulation, processing of histone pre-mRNAs, and co-regulation of transcription. Recently, we identified FLASH as a co-activator of the transcription factor c-Myb and found FLASH to be tightly associated with active transcription foci. As a huge multifunctional protein, FLASH is expected to have many interaction partners, some which may shed light on its function as a transcriptional regulator. Results To find additional FLASH-associated proteins, we performed a yeast two-hybrid (Y2H) screening with FLASH as bait and identified the SUMO E3 ligase PIAS1 as an interaction partner. The association appears to involve two distinct interaction surfaces in FLASH. We verified the interaction by Y2H-mating, GST pulldowns, co-IP and ChIP. FLASH and PIAS1 were found to co-localize in nuclear speckles. Functional assays revealed that PIAS1 enhances the intrinsic transcriptional activity of FLASH in a RING finger-dependent manner. Furthermore, PIAS1 also augments the specific activity of c-Myb, and cooperates with FLASH to further co-activate c-Myb. The three proteins, FLASH, PIAS1, and c-Myb, are all co-localized with active RNA polymerase II foci, resembling transcription factories. Conclusions We conclude that PIAS1 is a common partner for two cancer-related nuclear factors, c-Myb and FLASH. Our results point to a functional cooperation between FLASH and PIAS1 in the enhancement of c-Myb activity in active nuclear foci. PMID:21338522
Lazrus, Heather; Morss, Rebecca E; Demuth, Julie L; Lazo, Jeffrey K; Bostrom, Ann
2016-02-01
Understanding how people view flash flood risks can help improve risk communication, ultimately improving outcomes. This article analyzes data from 26 mental models interviews about flash floods with members of the public in Boulder, Colorado, to understand their perspectives on flash flood risks and mitigation. The analysis includes a comparison between public and professional perspectives by referencing a companion mental models study of Boulder-area professionals. A mental models approach can help to diagnose what people already know about flash flood risks and responses, as well as any critical gaps in their knowledge that might be addressed through improved risk communication. A few public interviewees mentioned most of the key concepts discussed by professionals as important for flash flood warning decision making. However, most interviewees exhibited some incomplete understandings and misconceptions about aspects of flash flood development and exposure, effects, or mitigation that may lead to ineffective warning decisions when a flash flood threatens. These include important misunderstandings about the rapid evolution of flash floods, the speed of water in flash floods, the locations and times that pose the greatest flash flood risk in Boulder, the value of situational awareness and environmental cues, and the most appropriate responses when a flash flood threatens. The findings point to recommendations for ways to improve risk communication, over the long term and when an event threatens, to help people quickly recognize and understand threats, obtain needed information, and make informed decisions in complex, rapidly evolving extreme weather events such as flash floods. © 2015 Society for Risk Analysis.
Hot Flashes and Carotid Intima Media Thickness among Midlife Women
Thurston, Rebecca C.; Sutton-Tyrrell, Kim; Everson-Rose, Susan A.; Hess, Rachel; Powell, Lynda H.; Matthews, Karen A.
2010-01-01
Objective Emerging evidence suggests associations between menopausal hot flashes and cardiovascular risk. Whether hot flashes are associated with intima media thickness (IMT) or IMT changes over time is unknown. We hypothesized that reported hot flashes would be associated with greater IMT cross-sectionally and with greater IMT progression over two years. Methods Participants were 432 women ages 45-58 at baseline participating in SWAN Heart, an ancillary study to the Study of Women's Health Across the Nation. Measures at the SWAN Heart baseline and follow-up visit two years later included a carotid artery ultrasound, reported hot flashes (past two weeks: none, 1-5, ≥6 days), and a blood sample for measurement of estradiol. Results Women reporting hot flashes ≥6 days in the prior two weeks had significantly higher IMT than women without hot flashes at baseline (mean difference(SE), mm =0.02(0.01), p=0.03) and follow-up (mean difference(SE), mm =0.02(0.01), p=0.04) visits, controlling for demographic factors and cardiovascular risk factors. Reporting hot flashes at both study visits was associated with higher follow-up IMT relative to reporting hot flashes at neither visit (mean difference(SE), mm=0.03(0.01), p=0.03). Associations between hot flashes and IMT largely remained after adjusting for estradiol. An interaction between hot flashes and obesity status was observed (p=0.05) such that relations between hot flashes and IMT were observed principally among overweight/obese women. Hot flashes were not associated with IMT progression. Conclusions These findings provided some indication that women reporting hot flashes ≥6 days in the prior two weeks may have higher IMT than women without hot flashes, particularly for women who are overweight or obese. Further work should determine whether hot flashes mark adverse underlying vascular changes. PMID:21242820
50 CFR 600.730 - Facilitation of enforcement.
Code of Federal Regulations, 2011 CFR
2011-10-01
... transmitted by flashing light directed at the vessel signaled. USCG units will normally use the flashing light... your vessel instantly.” (Period (.) means a short flash of light; dash (-) means a long flash of light... authorized officer using loudhailer, radiotelephone, flashing light signal, or other means constitutes prima...
50 CFR 600.730 - Facilitation of enforcement.
Code of Federal Regulations, 2010 CFR
2010-10-01
... transmitted by flashing light directed at the vessel signaled. USCG units will normally use the flashing light... your vessel instantly.” (Period (.) means a short flash of light; dash (-) means a long flash of light... authorized officer using loudhailer, radiotelephone, flashing light signal, or other means constitutes prima...
49 CFR 234.217 - Flashing light units.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Flashing light units. 234.217 Section 234.217..., Inspection, and Testing Maintenance Standards § 234.217 Flashing light units. (a) Each flashing light unit.... (b) Each flashing light unit shall be maintained to prevent dust and moisture from entering the...
49 CFR 234.217 - Flashing light units.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Flashing light units. 234.217 Section 234.217..., Inspection, and Testing Maintenance Standards § 234.217 Flashing light units. (a) Each flashing light unit.... (b) Each flashing light unit shall be maintained to prevent dust and moisture from entering the...
NASA Technical Reports Server (NTRS)
Moser, D. E.; Suggs, R. M.; Kupferschmidt, L.; Feldman, J.
2015-01-01
A bright impact flash detected by the NASA Lunar Impact Monitoring Program in March 2013 brought into focus the importance of determining the impact flash location. A process for locating the impact flash, and presumably its associated crater, was developed using commercially available software tools. The process was successfully applied to the March 2013 impact flash and put into production on an additional 300 impact flashes. The goal today: provide a description of the geolocation technique developed.
FLASH Interface; a GUI for managing runtime parameters in FLASH simulations
NASA Astrophysics Data System (ADS)
Walker, Christopher; Tzeferacos, Petros; Weide, Klaus; Lamb, Donald; Flocke, Norbert; Feister, Scott
2017-10-01
We present FLASH Interface, a novel graphical user interface (GUI) for managing runtime parameters in simulations performed with the FLASH code. FLASH Interface supports full text search of available parameters; provides descriptions of each parameter's role and function; allows for the filtering of parameters based on categories; performs input validation; and maintains all comments and non-parameter information already present in existing parameter files. The GUI can be used to edit existing parameter files or generate new ones. FLASH Interface is open source and was implemented with the Electron framework, making it available on Mac OSX, Windows, and Linux operating systems. The new interface lowers the entry barrier for new FLASH users and provides an easy-to-use tool for experienced FLASH simulators. U.S. Department of Energy (DOE), NNSA ASC/Alliances Center for Astrophysical Thermonuclear Flashes, U.S. DOE NNSA ASC through the Argonne Institute for Computing in Science, U.S. National Science Foundation.
OTD Observations of Continental US Ground and Cloud Flashes
NASA Technical Reports Server (NTRS)
Koshak, William
2007-01-01
Lightning optical flash parameters (e.g., radiance, area, duration, number of optical groups, and number of optical events) derived from almost five years of Optical Transient Detector (OTD) data are analyzed. Hundreds of thousands of OTD flashes occurring over the continental US are categorized according to flash type (ground or cloud flash) using US National Lightning Detection Network TM (NLDN) data. The statistics of the optical characteristics of the ground and cloud flashes are inter-compared on an overall basis, and as a function of ground flash polarity. A standard two-distribution hypothesis test is used to inter-compare the population means of a given lightning parameter for the two flash types. Given the differences in the statistics of the optical characteristics, it is suggested that statistical analyses (e.g., Bayesian Inference) of the space-based optical measurements might make it possible to successfully discriminate ground and cloud flashes a reasonable percentage of the time.
Menopausal Hot Flashes and White Matter Hyperintensities
Thurston, Rebecca C.; Aizenstein, Howard J.; Derby, Carol A.; Sejdić, Ervin; Maki, Pauline M.
2015-01-01
Objective Hot flashes are the classic menopausal symptom. Emerging data links hot flashes to cardiovascular disease (CVD) risk, yet how hot flashes are related to brain health is poorly understood. We examined the relationship between hot flashes - measured via physiologic monitor and self-report - and white matter hyperintensities (WMH) among midlife women. Methods Twenty midlife women ages 40-60 without clinical CVD, with their uterus and both ovaries, and not taking hormone therapy were recruited. Women underwent 24 hours of ambulatory physiologic and diary hot flash monitoring to quantify hot flashes; magnetic resonance imaging to assess WMH burden; 72 hours of actigraphy and questionnaires to quantify sleep; and a blood draw, questionnaires, and physical measures to quantify demographics and CVD risk factors. Test of a priori hypotheses regarding relations between physiologically-monitored and self-reported wake and sleep hot flashes and WMH were conducted in linear regression models. Results More physiologically-monitored hot flashes during sleep were associated with greater WMH, controlling for age, race, and body mass index [beta(standard error)=.0002 (.0001), p=.03]. Findings persisted controlling for sleep characteristics and additional CVD risk factors. No relations were observed for self-reported hot flashes. Conclusions More physiologically-monitored hot flashes during sleep were associated with greater WMH burden among midlife women free of clinical CVD. Results suggest that relations between hot flashes and CVD risk observed in the periphery may extend to the brain. Future work should consider the unique role of sleep hot flashes in brain health. PMID:26057822
NASA Astrophysics Data System (ADS)
Zhu, Baoyou; Ma, Ming; Xu, Weiwei; Ma, Dong
2015-12-01
Properties of negative cloud-to-ground (CG) lightning flashes, in terms of number of strokes per flash, inter-stroke intervals and the relative intensity of subsequent and first strokes, were presented by accurate-stroke-count studies based on all 1085 negative flashes from a local thunderstorm. The percentage of single-stroke flashes and stroke multiplicity evolved significantly during the whole life cycle of the study thunderstorm. The occurrence probability of negative CG flashes decreased exponentially with the increasing number of strokes per flash. About 30.5% of negative CG flashes contained only one stroke and number of strokes per flash averaged 3.3. In a subset of 753 negative multiple-stroke flashes, about 41.4% contained at least one subsequent stroke stronger than the corresponding first stroke. Subsequent strokes tended to decrease in strength with their orders and the ratio of subsequent to first stroke peaks presented a geometric mean value of 0.52. Interestingly, negative CG flashes of higher multiplicity tended to have stronger initial strokes. 2525 inter-stroke intervals showed a more or less log-normal distribution and gave a geometric mean value of 62 ms. For CG flashes of particular multiplicity geometric mean inter-stroke intervals tended to decrease with the increasing number of strokes per flash, while those intervals associated with higher order strokes tended to be larger than those associated with low order strokes.
Effect of Escitalopram on Hot Flash Interference: A Randomized, Controlled Trial
Carpenter, Janet S.; Guthrie, Katherine A.; Larson, Joseph C.; Freeman, Ellen W.; Joffe, Hadine; Reed, Susan D.; Ensrud, Kristine E.; LaCroix, Andrea Z.
2012-01-01
Objectives To estimate the effect of escitalopram 10–20 mg/day versus placebo for reducing hot flash interference in daily life and understand correlates and predictors of reductions in hot flash interference, a key measure of quality of life. Design Multi-site, randomized, double-blind, placebo-controlled clinical trial. Patients 205 midlife women (46% African-American) who met criteria participated. Setting MsFLASH clinical sites in Boston, Indianapolis, Oakland, and Philadelphia. Intervention After baseline, women were randomized to 1 pill of escitalopram 10 mg/day (n=104) or placebo (n=101) with follow-up at 4- and 8-weeks. At week 4, those not achieving 50% fewer hot flashes were increased to 2 pills daily (20 mg/day or 2 placebo pills). Main outcome measures The Hot Flash Related Daily Interference Scale; Correlates were variables from hot flash diaries; Predictors were baseline demographics, clinical variables, depression, anxiety, sleep quality, and hot flashes. Results Compared to placebo, escitalopram significantly reduced hot flash interference by 6.0 points at week 4 and 3.4 points at week 8 more than placebo (p=0.012). Reductions in hot flash interference correlated with changes in hot flash diary variables. However, baseline variables did not significantly predict reductions in hot flash interference. Conclusions Escitalopram 10–20mg/day for 8 weeks improves women’s quality of life and this benefit did not vary by demographic, clinical, mood, sleep, or hot flash variables. PMID:22480818
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ferrero, A; Chen, B; Huang, A
Purpose: In order to investigate novel methods to more accurately estimate the mineral composition of kidney stones using dual energy CT, it is desirable to be able to combine digital stones of known composition with actual phantom and patient scan data. In this work, we developed and validated a method to insert digital kidney stones into projection data acquired on a dual-source, dual-energy CT system. Methods: Attenuation properties of stones of different mineral composition were computed using tabulated mass attenuation coefficients, the chemical formula for each stone type, and the effective beam energy at each evaluated tube potential. A previouslymore » developed method to insert lesions into x-ray CT projection data was extended to include simultaneous dual-energy CT projections acquired on a dual-source gantry (Siemens Somatom Flash). Digital stones were forward projected onto both detectors and the resulting projections added to the physically acquired sinogram data. To validate the accuracy of the technique, digital stones were inserted into different locations in the ACR CT accreditation phantom; low and high contrast resolution, CT number accuracy and noise properties were compared before and after stone insertion. The procedure was repeated for two dual-energy tube potential pairs in clinical use on the scanner, 80/Sn140 kV and 100/Sn140 kV, respectively. Results: The images reconstructed after the insertion of digital kidney stones were consistent with the images reconstructed from the scanner. The largest average CT number difference for the 4 insert in the CT number accuracy module of the phantom was 3 HU. Conclusion: A framework was developed and validated for the creation of digital kidney stones of known mineral composition, and their projection-domain insertion into commercial dual-source, dual-energy CT projection data. This will allow a systematic investigation of the impact of scan and reconstruction parameters on stone attenuation and dual-energy behavior under rigorously controlled conditions. Dr. McCollough receives research support from Siemens Healthcare.« less
Cardiac autonomic function and hot flashes among perimenopausal and postmenopausal women.
Gibson, Carolyn J; Mendes, Wendy Berry; Schembri, Michael; Grady, Deborah; Huang, Alison J
2017-07-01
Abnormalities in autonomic function are posited to play a pathophysiologic role in menopausal hot flashes. We examined relationships between resting cardiac autonomic activity and hot flashes in perimenopausal and postmenopausal women. Autonomic function was assessed at baseline and 12 weeks among perimenopausal and postmenopausal women (n = 121, mean age 53 years) in a randomized trial of slow-paced respiration for hot flashes. Pre-ejection period (PEP), a marker of sympathetic activation, was measured with impedance cardiography. Respiratory sinus arrhythmia (RSA), a marker of parasympathetic activation, was measured with electrocardiography. Participants self-reported hot flash frequency and severity in 7-day symptom diaries. Analysis of covariance models were used to relate autonomic function and hot flash frequency and severity at baseline, and to relate changes in autonomic function to changes in hot flash frequency and severity over 12 weeks, adjusting for age, body mass index, and intervention assignment. PEP was not associated with hot flash frequency or severity at baseline or over 12 weeks (P > 0.05 for all). In contrast, there was a trend toward greater frequency of moderate-to-severe hot flashes with higher RSA at baseline (β = 0.43, P = 0.06), and a positive association between change in RSA and change in frequency of moderate-to-severe hot flashes over 12 weeks (β = 0.63, P = 0.04). Among perimenopausal and postmenopausal women with hot flashes, variations in hot flash frequency and severity were not explained by variations in resting sympathetic activation. Greater parasympathetic activation was associated with more frequent moderate-to-severe hot flashes, which may reflect increased sensitivity to perceiving hot flashes.
Canaani, Ora; Malkin, Shmuel; Mauzerall, David
1988-01-01
Photoacoustic signals from intact leaves, produced upon excitation with single-turnover flashes, were shown to be dependent on their position in the flash sequence. Compared to the signal obtained from the first flash, all the others were time-shifted and had increased amplitudes. The signal from the third flash had the largest deviation, whereas that from the second flash deviated only minimally. The amplitude difference of the signals relative to that from the first flash was measured at a convenient time point (5 ms) and showed oscillations of period 4, similar to the O2-evolution pattern from algae. These oscillations were strongly damped, tending to a steady state from about the seventh flash on. The extra photoacoustic signal (relative to the first flash) was shown to be inhibited by 3-(3,4-dichlorophenyl)-1,1-dimethylurea, heat treatment, or water infiltration. Its change with flash number, its saturation with increasing flash energy, and the above inhibition criteria indicate that it originates in pulsed O2 evolution. The sound wave produced by the first flash, however, arose by a photothermal mechanism only, as shown by its linear dependence on the flash intensity and insensitivity to the above treatments. The above flash pattern demonstrates that the photocycle of the S states (i.e., positive charge accumulation before two water molecules can be oxidized in a concerted way to produce molecular oxygen) occurs in intact leaves. It proves the applicability of the photoacoustic method for mechanistic studies of O2 evolution in leaves under physiological conditions. Water content of leaves is readily measured by this method. Images PMID:16593952
Understanding the complex relationships underlying hot flashes: a Bayesian network approach.
Smith, Rebecca L; Gallicchio, Lisa M; Flaws, Jodi A
2018-02-01
The mechanism underlying hot flashes is not well-understood, primarily because of complex relationships between and among hot flashes and their risk factors. We explored those relationships using a Bayesian network approach based on a 2006 to 2015 cohort study of hot flashes among 776 female residents, 45 to 54 years old, in the Baltimore area. Bayesian networks were fit for each outcome (current hot flashes, hot flashes before the end of the study, hot flash severity, hot flash frequency, and age at first hot flashes) separately and together with a list of risk factors (estrogen, progesterone, testosterone, body mass index and obesity, race, income level, education level, smoking history, drinking history, and activity level). Each fitting was conducted separately on all women and only perimenopausal women, at enrollment and 4 years after enrollment. Hormone levels, almost always interrelated, were the most common variable linked to hot flashes; hormone levels were sometimes related to body mass index, but were not directly related to any other risk factors. Smoking was also frequently associated with increased likelihood of severe symptoms, but not through an antiestrogenic pathway. The age at first hot flashes was related only to race. All other factors were either not related to outcomes or were mediated entirely by race, hormone levels, or smoking. These models can serve as a guide for design of studies into the causal network underlying hot flashes.
... report menopausal hot flashes than do women of European descent. Hot flashes are less common in women of Japanese and Chinese descent than in white European women. Complications Nighttime hot flashes (night sweats) can ...
Helium shell flashes and evolution of accreting white dwarfs
NASA Astrophysics Data System (ADS)
Fujimoto, M. Y.; Sugimoto, D.
1982-06-01
The evolution of accreting white dwarfs is investigated from the onset of accretion through the helium shell flash. Properties of the helium shell flashes are studied by means of a generalized theory of shell flash and by numerical computations, and it is found that the shell flash grows up to the strength of a supernova explosion when the mass of the helium zone is large enough on a massive white dwarf. Although accretion onto a hot white dwarf causes a weaker shell flash than those onto cool ones, a strong tendency exists for the strength to be determined mainly by the accretion rate. For fast accretion, the shell flashes are weak and triggered recurrently, while for slow accretion the helium shell flash, once triggered, develops into a detonation supernova.
Huang, Wan-Yu; Hsin, I-Lun; Chen, Dar-Ren; Chang, Chia-Chu; Kor, Chew-Teng; Chen, Ting-Yu; Wu, Hung-Ming
2017-01-01
Hot flashes have been postulated to be linked to systemic inflammation. This study aimed to investigate the relationship between hot flashes, pro-inflammatory factors, and leukocytes in healthy, non-obese postmenopausal women. In this cross-sectional study, a total of 202 women aged 45-60 years were stratified into one of four groups according to their hot-flash status: never experienced hot flashes (Group N), mild hot flashes (Group m), moderate hot flashes (Group M), and severe hot flashes (Group S). Variables measured in this study included clinical parameters, hot flash experience, leukocytes, and fasting plasma levels of nine circulating cytokines/chemokines measured by using multiplex assays. Multiple linear regression analysis was used to evaluate the associations of hot flashes with these pro-inflammatory factors. The study was performed in a hospital medical center. The mean values of leukocyte number were not different between these four groups. The hot flash status had a positive tendency toward increased levels of circulating IL-6 (P-trend = 0.049), IL-8 (P-trend < 0.001), TNF-α (P-trend = 0.008), and MIP1β (P-trend = 0.04). Multivariate linear regression analysis revealed that hot-flash severity was significantly associated with IL-8 (P-trend < 0.001) and TNFα (P-trend = 0.007) among these nine cytokines/chemokines after adjustment for age, menopausal duration, BMI and FSH. Multivariate analysis further revealed that severe hot flashes were strongly associated with a higher IL-8 (% difference, 37.19%; 95% confidence interval, 14.98,63.69; P < 0.001) and TNFα (51.27%; 6.64,114.57; P < 0.05). The present study provides evidence that hot flashes are associated with circulating IL-8 and TNF-α in healthy postmenopausal women. It suggests that hot flashes might be related to low-grade systemic inflammation.
Expectancy after the first treatment and response to acupuncture for menopausal hot flashes.
Ee, Carolyn C; Thuraisingam, Sharmala; Pirotta, Marie V; French, Simon D; Xue, Charlie C; Teede, Helena J
2017-01-01
Evidence on the impact of expectancy on acupuncture treatment response is conflicting. This secondary analysis of a randomized sham-controlled trial on acupuncture for menopausal hot flashes investigated whether treatment expectancy score was associated with hot flash score at end-of-treatment. Secondary analyses investigated whether there were associations between other pre-specified factors and hot flash score. Women experiencing moderately-severe hot flashes were randomized to receive 10 sessions of real or sham acupuncture over eight weeks. Hot flash score was collected using a seven-day hot flash diary, and expectancy using the modified Credibility and Expectancy Questionnaire immediately after the first treatment. Linear mixed-effects models with random intercepts were used to identify associations between expectancy score and hot flash score at end-of-treatment. Regression was also used to identify associations between pre-specified factors of interest and hot flash score. Because there was no difference between real and sham acupuncture for the primary outcome of hot flash score, both arms were combined in the analysis. 285 women returned the Credibility and Expectancy Questionnaire, and 283 women completed both expectancy measures. We found no evidence for an association between expectancy and hot flash score at end-of-treatment for individual cases in either acupuncture or sham group. Hot flash scores at end-of-treatment were 8.1 (95%CI, 3.0 to 13.2; P = 0.002) points lower in regular smokers compared to those who had never smoked, equivalent to four fewer moderate hot flashes a day. In our study of acupuncture for menopausal hot flashes, higher expectancy after the first treatment did not predict better treatment outcomes. Future research may focus on other determinants of outcomes in acupuncture such as therapist attention. The relationship between smoking and hot flashes is poorly understood and needs further exploration.
Huang, Wan-Yu; Hsin, I-Lun; Chen, Dar-Ren; Chang, Chia-Chu; Kor, Chew-Teng; Chen, Ting-Yu
2017-01-01
Introduction Hot flashes have been postulated to be linked to systemic inflammation. This study aimed to investigate the relationship between hot flashes, pro-inflammatory factors, and leukocytes in healthy, non-obese postmenopausal women. Participants and design In this cross-sectional study, a total of 202 women aged 45–60 years were stratified into one of four groups according to their hot-flash status: never experienced hot flashes (Group N), mild hot flashes (Group m), moderate hot flashes (Group M), and severe hot flashes (Group S). Variables measured in this study included clinical parameters, hot flash experience, leukocytes, and fasting plasma levels of nine circulating cytokines/chemokines measured by using multiplex assays. Multiple linear regression analysis was used to evaluate the associations of hot flashes with these pro-inflammatory factors. Settings The study was performed in a hospital medical center. Results The mean values of leukocyte number were not different between these four groups. The hot flash status had a positive tendency toward increased levels of circulating IL-6 (P-trend = 0.049), IL-8 (P-trend < 0.001), TNF-α (P-trend = 0.008), and MIP1β (P-trend = 0.04). Multivariate linear regression analysis revealed that hot-flash severity was significantly associated with IL-8 (P-trend < 0.001) and TNFα (P-trend = 0.007) among these nine cytokines/chemokines after adjustment for age, menopausal duration, BMI and FSH. Multivariate analysis further revealed that severe hot flashes were strongly associated with a higher IL-8 (% difference, 37.19%; 95% confidence interval, 14.98,63.69; P < 0.001) and TNFα (51.27%; 6.64,114.57; P < 0.05). Conclusion The present study provides evidence that hot flashes are associated with circulating IL-8 and TNF-α in healthy postmenopausal women. It suggests that hot flashes might be related to low-grade systemic inflammation. PMID:28846735
Muzzle flash issues related to the Waco FLIR analysis
NASA Astrophysics Data System (ADS)
Grant, Barbara G.; Hardy, David T.
2001-09-01
The controversy surrounding the origin of flashes on the Mt. Carmel FLIR videotape acquired on April 19, 1993, is introduced. The characteristics of muzzle flash are reviewed. A comparative weapons description is offered. The temporal, spatial, and radiance characteristics of thermal infrared muzzle flash are addressed. Data acquired from a field experiment are presented. The authors conclude that the spatial characteristics of muzzle flash enable its detection by equipment such as the FLIR in use at Mt. Carmel on April 19, 1993; that while flashes obtained in the field appear highly radiant, measurements are necessary to quantify their values; and that the temporal behavior of muzzle flash deserves further study.
Initial Breakdown Pulse Parameters in Intracloud and Cloud-to-Ground Lightning Flashes
NASA Astrophysics Data System (ADS)
Smith, E. M.; Marshall, T. C.; Karunarathne, S.; Siedlecki, R.; Stolzenburg, M.
2018-02-01
This study analyzes the largest initial breakdown (IB) pulse in flashes from four storms in Florida; data from three sensor arrays are used. The range-normalized, zero-to-peak amplitude of the largest IB pulse was determined along with its altitude, duration, and timing within each flash. Appropriate data were available for 40 intracloud (IC) and 32 cloud-to-ground (CG) flashes. Histograms of amplitude of the largest IB pulse by flash type were similar, with mean (median) values of 1.49 (1.05) V/m for IC flashes and -1.35 (-0.87) V/m for CG flashes. The largest IB pulse in 30 IC flashes showed a weak inverse relation between pulse amplitude and altitude. Amplitude of the largest IB pulse for 25 CG flashes showed no altitude correlation. Duration of the largest IB pulse in ICs averaged twice as long as in CGs (96 μs versus 46 μs), and all of the CG durations were <100 μs. Among the ICs, there is a positive relation between largest IB pulse duration and amplitude; the linear correlation coefficient is 0.385 with outliers excluded. The largest IB pulse in IC flashes typically occurred at a longer time after the first IB pulse (average 4.1 ms) than was the case in CG flashes (average 0.6 ms). In both flash types, the largest IB pulse was the first IB pulse in about 30% of the cases. In one storm all 42 IC flashes with triggered data had IB pulses.
Web Delivery of Interactive Laboratories: Comparison of Three Authoring Tools.
NASA Astrophysics Data System (ADS)
Silbar, Richard R.
2001-11-01
It is well-known that the more the end user (e.g., a student) interacts with a subject, the better he or she will learn it. This is particularly so in technical subjects. One way to do this is to have "laboratories" in which the student manipulates objects on the screen with keyboard or mouse and then sees the outcome of those actions. An example of such a laboratory can be seen at http://www.whistlesoft.com/ silbar/demo/vecadd, which deals with addition of two vectors in the geometric approach. This laboratory was built using Macromedia's Authorware. The problem with Authorware for this purpose is that, if one wants to deliver the training over the Web, that requires the download and installation of a big plug-in. As an experiment I recently tried to build clones of the Vector Addition Laboratory using Macromedia's Director or Flash, each of which have smaller plug-ins which are often already installed in the user's browser. I was able to come up with Director and Flash versions that are similar to (but definitely not the same as) the Authorware version. This talk goes into these differences and demonstrates the techniques used.
Anticipating flash-floods: Multi-scale aspects of the social response
NASA Astrophysics Data System (ADS)
Lutoff, Céline; Creutin, Jean-Dominique; Ruin, Isabelle; Borga, Marco
2016-10-01
This paper aims at exploring the anticipation phase before a flash flood, corresponding to the time between the first climatic signs and the peak-flow. We focus the analysis on people's behaviors observing how they use this period to organize themselves for facing the event. The analysis is made through the definition of three specific scales: the timeliness scale, an analytical scale of anticipatory actions and the scale of human response network. Using a cross-scale and cross level analysis enables to define different phases in the anticipation period where different kind of environmental precursors are mobilized by the actors in order to make sense of the situation and adapt. Three main points deserve attention at the end: firstly, the concepts of timeliness, anticipatory actions and crisis network scales enable to understand differently what happens both physically and socially during an extreme event; secondly, analyzing the precursors shows that each level of crisis network uses different kinds of signs for estimating the situation, organizing and reacting; thirdly, there is a potential for improvement in observation on both social and physical processes at different scales, for verifying the theory of the anticipatory phases.
Cloud-to-ground lightning and surface rainfall in warm-season Florida thunderstorms
Gungle, B.; Krider, E.P.
2006-01-01
Relationships between cloud-to-ground (CG) lightning and surface rainfall have been examined in nine isolated, warm-season thunderstorms on the east coast of central Florida. CG flashes and the associated rain volumes were measured as a function of time in storm-centered reference frames that followed each storm over a network of rain gauges. Values of the storm-average rain volume per CG flash ranged from 0.70 ?? 104 to 6.4 ?? 104 m3/CG flash, with a mean (and standard deviation) of 2.6 ?? 104 ?? 2.1 ?? 104 m3/CG flash. Values of the rain volume concurrent with CG flashes ranged from 0.11 ?? 104 to 4.9 ?? 104 m3/CG flash with a mean of 2.1 ?? 104 ?? 2.0 ?? 104 m3/CG flash. The lag-time between the peak CG flash rate and the peak rainfall rate (using 5 min bins), and the results of a lag correlation analysis, show that surface rainfall tends to follow the lightning (positive lag) by up to 20 min in six storms. In one storm the rainfall preceded the lightning by 5 min, and two storms had nonsignificant lags. Values of the lagged rain volume concurrent with CG flashes ranged from 0.43 ?? 104 to 4.9 ?? 104 m3/CG flash, and the mean was 1.9 ?? 104 ?? 1.7 ?? 104 m3/CG flash. For the five storms that produced 12 or more flashes and had significant lags, a plot of the optimum lag time versus the total number of CG flashes shows a linear trend (R2 = 0.56). The number of storms is limited, but the lag results do indicate that large storms tend to have longer lags. A linear fit to the lagged rain volume vs. the number of concurrent CG flashes has a slope of 1.9 ?? 104 m3/CG flash (R2 = 0.83). We conclude that warm-season Florida thunderstorms produce a roughly constant rain volume per CG flash and that CG lightning can be used to estimate the location and intensity of convective rainfall in that weather regime. Copyright 2006 by the American Geophysical Union.
Brain blood flow and cardiovascular responses to hot flashes in postmenopausal women
Lucas, Rebekah A. I.; Ganio, Matthew S.; Pearson, James; Crandall, Craig G.
2012-01-01
Objective This study tested two related hypotheses: 1) that brain blood flow is reduced during the postmenopausal hot flash; and, 2) the magnitude of this reduction in brain blood flow is greater during hot flashes where blood pressure is reduced. Methods Eleven healthy, normotensive, postmenopausal women rested in a temperature-controlled laboratory (~25°C) for approximately 120 minutes while waiting for a hot flash to occur. The onset of a hot flash was objectively identified by an abrupt increase in sternal sweat rate (capacitance hygrometry). Middle cerebral artery blood velocity (MCAv, transcranial Doppler) and mean arterial pressure (Finometer®) were measured continuously. Each hot flash was divided into 8 equal segments and the segment with the largest reduction in MCAv and mean arterial pressure identified for each hot flash. Results Twenty-five hot flashes occurred during the experimental sessions (lasting 6.2 ± 2.8 min, 3 ± 1 hot flashes per participant). Seventy-six percent of hot flashes were accompanied by a clear reduction (greater than 5%) in brain blood flow. For all hot flashes, the average maximum decrease in MCAv was 12 ± 9% (7 ± 6 cm.s−1). This value did not correlate with corresponding changes in mean arterial pressure (R=0.36). Conclusion These findings demonstrate that hot flashes are often accompanied by clear reductions in brain blood flow that do not correspond with acute reductions in mean arterial blood pressure. PMID:23435027
Are menopausal hot flashes an evolutionary byproduct of postpartum warming?
Sievert, Lynnette Leidy; Masley, Allison
2015-04-01
Hot flashes are commonly associated with menopause, and some researchers have questioned whether the widespread phenomenon may somehow be adaptive. It has been hypothesized that hot flashes were selected to occur during the hypoestrogenic postpartum period as a mechanism to warm infants. The purpose of this study was to test whether postpartum hot flashes are similar to hot flashes associated with menopause and whether postpartum hot flashes are concordant with breast-feeding episodes. Women who gave birth within the past year (n = 20) and a comparison group of women who had not given birth in the past 2 years (n = 14) participated in interviews and anthropometric measures. All wore ambulatory skin conductance monitors for a mean of 6.5 hours during afternoons and early evenings. New mothers also recorded breast-feeding episodes. Objectively measured and subjectively reported hot flashes were compared between groups and in relation to breast-feeding and other variables. Age of infants ranged from 4 days to 11 months. New mothers were more likely to report feeling warmer than the comparison group (100% vs 7%) but were not significantly more likely to demonstrate hot flashes (35% vs 50%) or to report hot flashes (30% vs 21%) during the study period. Of 75 breast-feeding episodes, only 4% were concurrent with an objective hot flash, and only 9% were concurrent with a subjective hot flash. This study does not support the hypothesis that menopausal-like hot flashes evolved to warm infants during the postpartum period.
Post-Flash Validation of the new ACS/WFC Subarrays
NASA Astrophysics Data System (ADS)
Bellini, A.; Grogin, N. A.; Lim, P. L.; Golimowski, D.
2017-05-01
We made use of the new ACS/WFC subarray images of CAL-14410, taken taken with a large range of flash exposure times (0.1-30 seconds), to probe the temporal stability of the reference flash file and to validate the current post-flash correction pipeline of CALACS and ACS DESTRIPE PLUS on the new subarray modes. No statistically-significant deviations are found between the new post-flashed subarray exposures and the flash reference file, indicating that the LED lamp used to post-flash ACS images has been stable over several years. The current calibration pipelines (both CALACS and ACS DESTRIPE PLUS can be successfully used with the new subarray modes.
2011-03-01
than would be performed in software”[108]. Uro Tinic, one of the Flash player’s engineers, further clarifies exactly what Flash player 10 hardware...www.adobe.com/products/flashplayer/features/ (Access date: 28 Sep 2009). [109] Uro , T. What Does GPU Acceleration Mean? (online), http...133] Shorten, A. (2009), Design to Development: Flash Catalyst to Flash Builder, In Proceedings of Adobe Max 2009, Los Angeles, CA. 142 DRDC
The Evolution and Structure of Extreme Optical Lightning Flashes.
Peterson, Michael; Rudlosky, Scott; Deierling, Wiebke
2017-12-27
This study documents the composition, morphology, and motion of extreme optical lightning flashes observed by the Lightning Imaging Sensor (LIS). The furthest separation of LIS events (groups) in any flash is 135 km (89 km), the flash with the largest footprint had an illuminated area of 10,604 km 2 , and the most dendritic flash has 234 visible branches. The longest-duration convective LIS flash lasted 28 s and is overgrouped and not physical. The longest-duration convective-to-stratiform propagating flash lasted 7.4 s, while the longest-duration entirely stratiform flash lasted 4.3 s. The longest series of nearly consecutive groups in time lasted 242 ms. The most radiant recorded LIS group (i.e., "superbolt") is 735 times more radiant than the average group. Factors that impact these optical measures of flash morphology and evolution are discussed. While it is apparent that LIS can record the horizontal development of the lightning channel in some cases, radiative transfer within the cloud limits the flash extent and level of detail measured from orbit. These analyses nonetheless suggest that lightning imagers such as LIS and Geostationary Lightning Mapper can complement ground-based lightning locating systems for studying physical lightning phenomena across large geospatial domains.
Hold-up power supply for flash memory
NASA Technical Reports Server (NTRS)
Ott, William E. (Inventor)
2004-01-01
A hold-up power supply for flash memory systems is provided. The hold-up power supply provides the flash memory with the power needed to temporarily operate when a power loss exists. This allows the flash memory system to complete any erasures and writes, and thus allows it to shut down gracefully. The hold-up power supply detects when a power loss on a power supply bus is occurring and supplies the power needed for the flash memory system to temporally operate. The hold-up power supply stores power in at least one capacitor. During normal operation, power from a high voltage supply bus is used to charge the storage capacitors. When a power supply loss is detected, the power supply bus is disconnected from the flash memory system. A hold-up controller controls the power flow from the storage capacitors to the flash memory system. The hold-up controller uses feedback to assure that the proper voltage is provided from the storage capacitors to the flash memory system. This power supplied by the storage capacitors allows the flash memory system to complete any erasures and writes, and thus allows the flash memory system to shut down gracefully.
Determination of flash point in air and pure oxygen using an equilibrium closed bomb apparatus.
Kong, Dehong; am Ende, David J; Brenek, Steven J; Weston, Neil P
2003-08-29
The standard closed testers for flash point measurements may not be feasible for measuring flash point in special atmospheres like oxygen because the test atmosphere cannot be maintained due to leakage and the laboratory safety can be compromised. To address these limitations we developed a new "equilibrium closed bomb" (ECB). The ECB generally gives lower flash point values than standard closed cup testers as shown by the results of six flammable liquids. The present results are generally in good agreement with the values calculated from the reported lower flammability limits and the vapor pressures. Our measurements show that increased oxygen concentration had little effect on the flash points of the tested flammable liquids. While generally regarded as non-flammable because of the lack of observed flash point in standard closed cup flash point testers, dichloromethane is known to form flammable mixtures. The flash point of dichloromethane in oxygen measured in the ECB is -7.1 degrees C. The flash point of dichloromethane in air is dependent on the type and energy of the ignition source. Further research is being carried out to establish the relationship between the flash point of dichloromethane and the energy of the ignition source.
Risk Factors for Extended Duration and Timing of Peak Severity of Hot Flashes
Gallicchio, Lisa; Miller, Susan R.; Zacur, Howard A.; Flaws, Jodi A.
2016-01-01
Objective To identify risk factors associated with the duration of hot flashes and the time of peak hot flash severity in mid-life women. Methods A cohort of 647 women reporting hot flashes were followed for 1–7 years, with survey data and hormone measurements. Survival analysis determined the association of risk factors with the duration of hot flashes. Linear regression determined the association of risk factors with the time of peak severity. Final models were determined through stepwise model selection. Results Average hot flash duration was 2.5 years (range: 1–33), with peak severity on average at 2.96 years (range: 1–20). Duration of hot flashes was associated with race, education, menopause status, smoking history, BMI, alcohol consumption, leisure activity levels, and levels of estradiol and progesterone. In the final model, only race, alcohol consumption, leisure activity, and menopause were retained. White women had significantly shorter hot flash durations than non-white women. Women consuming at least 12 alcoholic drinks in the previous year had a significantly shorter duration of hot flashes with a smaller effect of hot flash duration on increasing in time to peak severity compared to those who consumed less than 12 alcoholic drinks in that year. Higher serum progesterone levels were associated with later peak severity if the duration of the hot flashes was less than 2 years and an earlier peak severity otherwise. Conclusions These results suggest that some behaviors (such as moderate alcohol consumption) are associated with shorter durations of hot flashes, and that progesterone was associated with the dynamics of hot flash severity. PMID:27149066
Metabolic Activity in the Insular Cortex and Hypothalamus Predicts Hot Flashes: An FDG-PET Study
Deckersbach, Thilo; Lin, Nancy U.; Makris, Nikos; Skaar, Todd C.; Rauch, Scott L.; Dougherty, Darin D.; Hall, Janet E.
2012-01-01
Context: Hot flashes are a common side effect of adjuvant endocrine therapies (AET; leuprolide, tamoxifen, aromatase inhibitors) that reduce quality of life and treatment adherence in breast cancer patients. Because hot flashes affect only some women, preexisting neurobiological traits might predispose to their development. Previous studies have implicated the insula during the perception of hot flashes and the hypothalamus in thermoregulatory dysfunction. Objective: The aim of the study was to understand whether neurobiological factors predict hot flashes. Design: [18F]-Fluorodeoxyglucose (FDG) positron emission tomography (PET) brain scans coregistered with structural magnetic resonance imaging were used to determine whether metabolic activity in the insula and hypothalamic thermoregulatory and estrogen-feedback regions measured before and in response to AET predict hot flashes. Findings were correlated with CYP2D6 genotype because of CYP2D6 polymorphism associations with tamoxifen-induced hot flashes. Outcome Measures: We measured regional cerebral metabolic rate of glucose uptake (rCMRglu) in the insula and hypothalamus on FDG-PET. Results: Of 18 women without hot flashes who began AET, new-onset hot flashes were reported by 10 (55.6%) and were detected objectively in nine (50%) participants. Prior to the use of all AET, rCMRglu in the insula (P ≤ 0.01) and hypothalamic thermoregulatory (P = 0.045) and estrogen-feedback (P = 0.007) regions was lower in women who reported developing hot flashes. In response to AET, rCMRglu was further reduced in the insula in women developing hot flashes (P ≤ 0.02). Insular and hypothalamic rCMRglu levels were lower in intermediate than extensive CYP2D6 metabolizers. Conclusions: Trait neurobiological characteristics predict hot flashes. Genetic variability in CYP2D6 may underlie the neurobiological predisposition to hot flashes induced by AET. PMID:22723326
An unusual characteristic “flower-like” pattern: flash suppressor burns
Gurcan, Altun
2012-01-01
The case on contact shots from firearms with a flash suppressor is rare. When a rifle fitted with a flash suppressor is fired, the emerging soot-laden gas in the barrel escapes from the slits of the flash suppressor. If the shot is contact or near contact, the flash suppressor will produce a characteristic “flower-like” pattern of seared, blackened zones around the entrance. This paper presents the injury pattern of the flash suppressor in a 29-year-old man who committed suicide with a G3 automatic infantry rifle. PMID:23935280
An unusual characteristic "flower-like" pattern: flash suppressor burns.
Gurcan, Altun
2012-04-01
The case on contact shots from firearms with a flash suppressor is rare. When a rifle fitted with a flash suppressor is fired, the emerging soot-laden gas in the barrel escapes from the slits of the flash suppressor. If the shot is contact or near contact, the flash suppressor will produce a characteristic "flower-like" pattern of seared, blackened zones around the entrance. This paper presents the injury pattern of the flash suppressor in a 29-year-old man who committed suicide with a G3 automatic infantry rifle.
Huang, Wan-Yu; Chang, Chia-Chu; Chen, Dar-Ren; Kor, Chew-Teng; Chen, Ting-Yu; Wu, Hung-Ming
2017-01-01
Hot flashes have been postulated to be linked to the development of metabolic disorders. This study aimed to evaluate the relationship between hot flashes, adipocyte-derived hormones, and insulin resistance in healthy, non-obese postmenopausal women. In this cross-sectional study, a total of 151 women aged 45-60 years were stratified into one of three groups according to hot-flash status over the past three months: never experienced hot flashes (Group N), mild-to-moderate hot flashes (Group M), and severe hot flashes (Group S). Variables measured in this study included clinical parameters, hot flash experience, fasting levels of circulating glucose, lipid profiles, plasma insulin, and adipocyte-derived hormones. Multiple linear regression analysis was used to evaluate the associations of hot flashes with adipocyte-derived hormones, and with insulin resistance. The study was performed in a hospital medical center. The mean (standard deviation) of body-mass index was 22.8(2.7) for Group N, 22.6(2.6) for Group M, and 23.5(2.4) for Group S, respectively. Women in Group S displayed statistically significantly higher levels of leptin, fasting glucose, and insulin, and lower levels of adiponectin than those in Groups M and N. Multivariate linear regression analysis revealed that hot-flash severity was significantly associated with higher leptin levels, lower adiponectin levels, and higher leptin-to-adiponectin ratio. Univariate linear regression analysis revealed that hot-flash severity was strongly associated with a higher HOMA-IR index (% difference, 58.03%; 95% confidence interval, 31.00-90.64; p < 0.001). The association between hot flashes and HOMA-IR index was attenuated after adjusting for leptin or adiponectin and was no longer significant after simultaneously adjusting for leptin and adiponectin. The present study provides evidence that hot flashes are associated with insulin resistance in postmenopausal women. It further suggests that hot flash association with insulin resistance is dependent on the combination of leptin and adiponectin variables.
Optimal flash rate and duty cycle for flashing visual indicators.
NASA Technical Reports Server (NTRS)
Markowitz, J.
1971-01-01
This experiment examined the ability of observers to determine, as quickly as possible, whether a visual indicator was steadily on or flashing. Six flash rates (periods) were combined factorially with three duty cycles (on-off ratios) to define 18 ?types' of intermittent signals. Experimental sessions were divided into six runs of 100 trials, each run utilizing one of the six flash rates. On any given trial in a run, the probability of a steady signal occurring was 0.5 and the probability of a flashing signal occurring was 0.5. A different duty cycle was employed daily for each experimental session. In all, 400 trials were devoted to each of the flash rates at each duty cycle. Accuracy and latency of response were the dependent variables of interest. The results show that the observers view the light for an interval of time appropriate to the expected flash rate and duty cycle; whether they judge the light to be steady or intermittent depends upon whether the light is extinguished during the predetermined waiting period. Adoption of this temporal criterion delays responding in comparison to those tasks involving responses to light onset. The decision or response criteria held by the observers are also sensitive to the parameters of the flashing light: observers become increasingly willing to call a flashing light ?steady' as flash duration increases.
Synchronized Electronic Shutter System (SESS) for Thermal Nondestructive Evaluation
NASA Technical Reports Server (NTRS)
Zalameda, Joseph N.
2001-01-01
The purpose of this paper is to describe a new method for thermal nondestructive evaluation. This method uses a synchronized electronic shutter system (SESS) to remove the heat lamp's influence on the thermal data during and after flash heating. There are two main concerns when using flash heating. The first concern is during the flash when the photons are reflected back into the camera. This tends to saturate the detectors and potentially introduces unknown and uncorrectable errors when curve fitting the data to a model. To address this, an electronically controlled shutter was placed over the infrared camera lens. Before firing the flash lamps, the shutter is opened to acquire the necessary background data for offset calibration. During flash heating, the shutter is closed to prevent the photons from the high intensity flash from saturating the camera's detectors. The second concern is after the flash heating where the lamps radiate heat after firing. This residual cooling introduces an unwanted transient thermal response into the data. To remove this residual effect, a shutter was placed over the flash lamps to block the infrared heat radiating from the flash head after heating. This helped to remove the transient contribution of the flash. The flash lamp shutters were synchronized electronically with the camera shutter. Results are given comparing the use of the thermal inspection with and without the shutter system.
Acupuncture as treatment of hot flashes and the possible role of calcitonin gene-related Peptide.
Spetz Holm, Anna-Clara E; Frisk, Jessica; Hammar, Mats L
2012-01-01
The mechanisms behind hot flashes in menopausal women are not fully understood. The flashes in women are probably preceded by and actually initiated by a sudden downward shift in the set point for the core body temperature in the thermoregulatory center that is affected by sex steroids, β-endorphins, and other central neurotransmitters. Treatments that influence these factors may be expected to reduce hot flashes. Since therapy with sex steroids for hot flashes has appeared to cause a number of side effects and risks and women with hot flashes and breast cancer as well as men with prostate cancer and hot flashes are prevented from sex steroid therapy there is a great need for alternative therapies. Acupuncture affecting the opioid system has been suggested as an alternative treatment option for hot flashes in menopausal women and castrated men. The heat loss during hot flashes may be mediated by the potent vasodilator and sweat gland activator calcitonin gene-related peptide (CGRP) the concentration of which increases in plasma during flashes in menopausal women and, according to one study, in castrated men with flushes. There is also evidence for connections between the opioid system and the release of CGRP. In this paper we discuss acupuncture as a treatment alternative for hot flashes and the role of CGRP in this context.
A spatially collocated sound thrusts a flash into awareness
Aller, Máté; Giani, Anette; Conrad, Verena; Watanabe, Masataka; Noppeney, Uta
2015-01-01
To interact effectively with the environment the brain integrates signals from multiple senses. It is currently unclear to what extent spatial information can be integrated across different senses in the absence of awareness. Combining dynamic continuous flash suppression (CFS) and spatial audiovisual stimulation, the current study investigated whether a sound facilitates a concurrent visual flash to elude flash suppression and enter perceptual awareness depending on audiovisual spatial congruency. Our results demonstrate that a concurrent sound boosts unaware visual signals into perceptual awareness. Critically, this process depended on the spatial congruency of the auditory and visual signals pointing towards low level mechanisms of audiovisual integration. Moreover, the concurrent sound biased the reported location of the flash as a function of flash visibility. The spatial bias of sounds on reported flash location was strongest for flashes that were judged invisible. Our results suggest that multisensory integration is a critical mechanism that enables signals to enter conscious perception. PMID:25774126
Application of adobe flash media to optimize jigsaw learning model on geometry material
NASA Astrophysics Data System (ADS)
Imam, P.; Imam, S.; Ikrar, P.
2018-05-01
This study aims to determine and describe the effectiveness of the application of adobe flash media for jigsaw learning model on geometry material. In this study, the modified jigsaw learning with adobe flash media is called jigsaw-flash model. This research was conducted in Surakarta. The research method used is mix method research with exploratory sequential strategy. The results of this study indicate that students feel more comfortable and interested in studying geometry material taught by jigsaw-flash model. In addition, students taught using the jigsaw-flash model are more active and motivated than the students who were taught using ordinary jigsaw models. This shows that the use of the jigsaw-flash model can increase student participation and motivation. It can be concluded that the adobe flash media can be used as a solution to reduce the level of student abstraction in learning mathematics.
46 CFR 35.20-30 - Flashing the rays of a searchlight or other blinding light-T/ALL.
Code of Federal Regulations, 2012 CFR
2012-10-01
... VESSELS OPERATIONS Navigation § 35.20-30 Flashing the rays of a searchlight or other blinding light—T/ALL. No person shall flash, or cause to be flashed, the rays of a search light or other blinding light... 46 Shipping 1 2012-10-01 2012-10-01 false Flashing the rays of a searchlight or other blinding...
46 CFR 35.20-30 - Flashing the rays of a searchlight or other blinding light-T/ALL.
Code of Federal Regulations, 2010 CFR
2010-10-01
... VESSELS OPERATIONS Navigation § 35.20-30 Flashing the rays of a searchlight or other blinding light—T/ALL. No person shall flash, or cause to be flashed, the rays of a search light or other blinding light... 46 Shipping 1 2010-10-01 2010-10-01 false Flashing the rays of a searchlight or other blinding...
46 CFR 35.20-30 - Flashing the rays of a searchlight or other blinding light-T/ALL.
Code of Federal Regulations, 2014 CFR
2014-10-01
... VESSELS OPERATIONS Navigation § 35.20-30 Flashing the rays of a searchlight or other blinding light—T/ALL. No person shall flash, or cause to be flashed, the rays of a search light or other blinding light... 46 Shipping 1 2014-10-01 2014-10-01 false Flashing the rays of a searchlight or other blinding...
46 CFR 35.20-30 - Flashing the rays of a searchlight or other blinding light-T/ALL.
Code of Federal Regulations, 2013 CFR
2013-10-01
... VESSELS OPERATIONS Navigation § 35.20-30 Flashing the rays of a searchlight or other blinding light—T/ALL. No person shall flash, or cause to be flashed, the rays of a search light or other blinding light... 46 Shipping 1 2013-10-01 2013-10-01 false Flashing the rays of a searchlight or other blinding...
46 CFR 35.20-30 - Flashing the rays of a searchlight or other blinding light-T/ALL.
Code of Federal Regulations, 2011 CFR
2011-10-01
... VESSELS OPERATIONS Navigation § 35.20-30 Flashing the rays of a searchlight or other blinding light—T/ALL. No person shall flash, or cause to be flashed, the rays of a search light or other blinding light... 46 Shipping 1 2011-10-01 2011-10-01 false Flashing the rays of a searchlight or other blinding...
Characteristics of flash initiations in a supercell cluster with tornadoes
NASA Astrophysics Data System (ADS)
Zheng, Dong; MacGorman, Donald R.
2016-01-01
Flash initiations within a supercell cluster during 10-11 May 2010 in Oklahoma were investigated based on observations from the Oklahoma Lightning Mapping Array and the Norman, Oklahoma, polarimetric radar (KOUN). The flash initiations at positions dominated by graupel, dry snow, small hail and crystals accounted for 44.3%, 44.1%, 8.0% and 3.0% of the total flashes, respectively. During the tornadic stage of the southern supercell in the cluster, flash initiations associated with graupel occupied the main body, the right flank and the forward flank of the supercell, while those associated with dry snow dominated the outskirts of the adjacent forward anvil, right anvil and rear anvil. The flash initiations associated with small hail were concentrated around the main updraft, particularly toward its front side. Highly dense flash initiations were located in the regions overlying the differential reflectivity (ZDR) arc and right anvil. The average initial height of the flashes decreased gradually from the rear to the front and from the right to the left flanks, while the height range over which initiations occurred reached a maximum at the front of the updraft. The flashes that were initiated in the adjacent forward anvils were largest on average, followed by those in the regions ahead of the updraft and near the ZDR arc. This study supports the concept of charge pockets and further deduces that the pockets in the right anvil are the most abundant and compact due to the frequent flash initiations, small-sized flashes and thin layers including flash initiations.
Phase II evaluation of S-adenosyl-L-methionine (SAMe) for the treatment of hot flashes.
Kadakia, Kunal C; Loprinzi, Charles L; Atherton, Pamela J; Fee-Schroeder, Kelliann C; Sood, Amit; Barton, Debra L
2016-03-01
Hot flashes are a significant source of symptom burden that negatively impacts quality of life (QOL). For women who have contraindications to, or are unwilling to consider, estrogens or antidepressants for bothersome hot flashes, there are limited effective pharmacologic or complementary and alternative medicines. This single-arm phase II trial studied the efficacy of S-adenosyl-L-methionine (SAMe) for the treatment of hot flashes. Eligible women were required to have reported ≥14 hot flashes per week for ≥1 month. The patients were treated with SAMe at a dose of 400 mg twice daily to evaluate whether a reduction in hot flash score appeared to be better than the historical placebo response of approximately 25%. The women kept a daily hot flash diary during a baseline week and then daily during weeks 2-7. The primary endpoint was the change from baseline to week 7 in hot flash score and hot flash frequency. Secondary endpoints included toxicity analyses and the effect of SAMe on QOL. From October 28, 2010 to January 30, 2012, 43 women were treated with SAMe. The decrease in mean percent of baseline hot flash score and frequency was 35.4 and 32.6%, respectively. When compared to the historical placebo response of 25%, the effect of SAMe on hot flash score was not statistically significant (p = 0.09). Treatment was well tolerated with expected grade 1/2 gastrointestinal toxicity and no negative effect on QOL. The use of SAMe does not appear to significantly reduce hot flashes more than would be expected with a placebo.
NASA Astrophysics Data System (ADS)
Wang, L.; Yuan, X.; Xie, Z.
2017-12-01
Flash drought has been receiving attention recently due to its rapid development and vast damage on crops in the growing season. Accompanied with heatwave and rainfall deficit, the soil moisture decreased rapidly in a short time and may lead to the failure of root water uptake and large-scale crops wither. There are two types of flash droughts according to the causes (Mo and Lettenmaier, 2016), i.e., heat wave flash drought and rainfall deficit flash drought. Here, based on pentad-mean surface air temperature and precipitation observations from over two thousand meteorological stations as well as soil moisture and ET estimations from three global reanalysis products, the characteristics and evolution of the two types of flash droughts over China are being explored. Heat wave flash drought is more likely to occur in humid and semi-humid areas, such as southern China, while rainfall deficit flash drought is more likely to occur in northern China. Unlike the traditional drought that persists for a few months to decades, the mean durations of both types of flash droughts are very short. We use monthly mean soil moisture to calculate sub-seasonal to seasonal (S2S) soil moisture drought, and compare its characteristics and preferred conditions such as the large-scale atmospheric circulation and oceanic anomaly for both types of flash droughts. The percentages of flash drought in different periods of S2S drought are also being explored to see the potential relationship between flash drought and S2S drought over different regions.
Temporal Binding Window of the Sound-Induced Flash Illusion in Amblyopia.
Narinesingh, Cindy; Goltz, Herbert C; Wong, Agnes M F
2017-03-01
Amblyopia is a neurodevelopmental visual disorder caused by abnormal visual experience in childhood. In addition to known visual deficits, there is evidence for changes in audiovisual integration in amblyopia using explicit tasks. We examined audiovisual integration in amblyopia using an implicit task that is more relevant in a real-world context. A total of 11 participants with amblyopia and 16 controls were tested binocularly and monocularly on the sound-induced flash illusion, in which flashes and beeps are presented concurrently and the perceived number of flashes is influenced by the number of beeps. The task used 1 to 2 rapid peripheral flashes presented with 0 to 2 beeps, at 5 stimulus onset asynchronies, that is, beep (-200 milliseconds, -100 milliseconds) or flash leading (100 milliseconds, 200 milliseconds) or simultaneous (0 milliseconds). Participants reported the number of perceived flashes. Susceptibility was indicated by a "2 flashes" response to "fission" (1 flash, 2 beeps) or "1 flash" to "fusion" (2 flashes, 1 beep). For fission with the beep leading during binocular viewing, controls showed an expected decrease in illusion strength as stimulus onset asynchronies increased, whereas the illusion strength remained constant in participants with amblyopia, indicating a wider temporal binding window in amblyopia (P = 0.007). For fusion, participants with amblyopia showed reduced illusion strength during amblyopic eye viewing (P = 0.044) with the flash leading. Amblyopia is associated with the widening of the temporal binding window, specifically for fission when viewing binocularly with the beep leading. This suggests a developmental adaptation to delayed amblyopic eye visual processing to optimize audiovisual integration.
Significant and variable linear polarization during the prompt optical flash of GRB 160625B.
Troja, E; Lipunov, V M; Mundell, C G; Butler, N R; Watson, A M; Kobayashi, S; Cenko, S B; Marshall, F E; Ricci, R; Fruchter, A; Wieringa, M H; Gorbovskoy, E S; Kornilov, V; Kutyrev, A; Lee, W H; Toy, V; Tyurina, N V; Budnev, N M; Buckley, D A H; González, J; Gress, O; Horesh, A; Panasyuk, M I; Prochaska, J X; Ramirez-Ruiz, E; Lopez, R Rebolo; Richer, M G; Román-Zúñiga, C; Serra-Ricart, M; Yurkov, V; Gehrels, N
2017-07-26
Newly formed black holes of stellar mass launch collimated outflows (jets) of ionized matter that approach the speed of light. These outflows power prompt, brief and intense flashes of γ-rays known as γ-ray bursts (GRBs), followed by longer-lived afterglow radiation that is detected across the electromagnetic spectrum. Measuring the polarization of the observed GRB radiation provides a direct probe of the magnetic fields in the collimated jets. Rapid-response polarimetric observations of newly discovered bursts have probed the initial afterglow phase, and show that, minutes after the prompt emission has ended, the degree of linear polarization can be as high as 30 per cent-consistent with the idea that a stable, globally ordered magnetic field permeates the jet at large distances from the central source. By contrast, optical and γ-ray observations during the prompt phase have led to discordant and often controversial results, and no definitive conclusions have been reached regarding the origin of the prompt radiation or the configuration of the magnetic field. Here we report the detection of substantial (8.3 ± 0.8 per cent from our most conservative simulation), variable linear polarization of a prompt optical flash that accompanied the extremely energetic and long-lived prompt γ-ray emission from GRB 160625B. Our measurements probe the structure of the magnetic field at an early stage of the jet, closer to its central black hole, and show that the prompt phase is produced via fast-cooling synchrotron radiation in a large-scale magnetic field that is advected from the black hole and distorted by dissipation processes within the jet.
Significant and variable linear polarization during the prompt optical flash of GRB 160625B.
NASA Astrophysics Data System (ADS)
Troja, E.; Lipunov, V. M.; Mundell, C. G.; Butler, N. R.; Watson, A. M.; Kobayashi, S.; Cenko, S. B.; Marshall, F. E.; Ricci, R.; Fruchter, A.; Wieringa, M. H.; Gorbovskoy, E. S.; Kornilov, V.; Kutyrev, A.; Lee, W. H.; Toy, V.; Tyurina, N. V.; Budnev, N. M.; Buckley, D. A. H.; González, J.; Gress, O.; Horesh, A.; Panasyuk, M. I.; Prochaska, J. X.; Ramirez-Ruiz, E.; Rebolo Lopez, R.; Richer, M. G.; Roman-Zuniga, C.; Serra-Ricart, M.; Yurkov, V.; Gehrels, N.
2017-07-01
Newly formed black holes of stellar mass launch collimated outflows (jets) of ionized matter that approach the speed of light. These outflows power prompt, brief and intense flashes of γ-rays known as γ-ray bursts (GRBs), followed by longer-lived afterglow radiation that is detected across the electromagnetic spectrum. Measuring the polarization of the observed GRB radiation provides a direct probe of the magnetic fields in the collimated jets. Rapid-response polarimetric observations of newly discovered bursts have probed the initial afterglow phase, and show that, minutes after the prompt emission has ended, the degree of linear polarization can be as high as 30 per cent - consistent with the idea that a stable, globally ordered magnetic field permeates the jet at large distances from the central source. By contrast, optical and γ-ray observations during the prompt phase have led to discordant and often controversial results, and no definitive conclusions have been reached regarding the origin of the prompt radiation or the configuration of the magnetic field. Here we report the detection of substantial (8.3 ± 0.8 per cent from our most conservative simulation), variable linear polarization of a prompt optical flash that accompanied the extremely energetic and long-lived prompt γ-ray emission from GRB 160625B. Our measurements probe the structure of the magnetic field at an early stage of the jet, closer to its central black hole, and show that the prompt phase is produced via fast-cooling synchrotron radiation in a large-scale magnetic field that is advected from the black hole and distorted by dissipation processes within the jet.
Onset conditions for flash sintering of UO 2
Raftery, Alicia M.; Pereira da Silva, João Gustavo; Byler, Darrin D.; ...
2017-06-22
In this paper, flash sintering was demonstrated on stoichiometric and non-stoichiometric uranium dioxide pellets at temperatures ranging from room temperature (26°C) up to 600°C. The onset conditions for flash sintering were determined for three stoichiometries (UO 2.00, UO 2.08, and UO 2.16) and analyzed against an established thermal runaway model. The presence of excess oxygen was found to enhance the flash sintering onset behavior of uranium dioxide, lowering the field required to flash and shortening the time required for a flash to occur. Finally, the results from this study highlight the effect of stoichiometry on the flash sintering behavior ofmore » uranium dioxide and will serve as the foundation for future studies on this material.« less
Onset conditions for flash sintering of UO2
NASA Astrophysics Data System (ADS)
Raftery, Alicia M.; Pereira da Silva, João Gustavo; Byler, Darrin D.; Andersson, David A.; Uberuaga, Blas P.; Stanek, Christopher R.; McClellan, Kenneth J.
2017-09-01
In this work, flash sintering was demonstrated on stoichiometric and non-stoichiometric uranium dioxide pellets at temperatures ranging from room temperature (26 °C) up to 600 °C . The onset conditions for flash sintering were determined for three stoichiometries (UO2.00, UO2.08, and UO2.16) and analyzed against an established thermal runaway model. The presence of excess oxygen was found to enhance the flash sintering onset behavior of uranium dioxide, lowering the field required to flash and shortening the time required for a flash to occur. The results from this study highlight the effect of stoichiometry on the flash sintering behavior of uranium dioxide and will serve as the foundation for future studies on this material.
NASA Technical Reports Server (NTRS)
Koshak, William
2007-01-01
Continental US lightning flashes observed by the Optical Transient Detector (OTD) are categorized according to flash type (ground or cloud flash) using US National Lightning Detection Network (TM) (NLDN) data. The statistics of the ground and cloud flash optical parameters (e.g., radiance, area, duration, number of optical groups, and number of optical events) are inter-compared. On average, the ground flash cloud-top emissions are more radiant, illuminate a larger area, are longer lasting, and have more optical groups and optical events than those cloud-top emissions associated with cloud flashes. Given these differences, it is suggested that the methods of Bayesian Inference could be used to help discriminate between ground and cloud flashes. The ability to discriminate flash type on-orbit is highly desired since such information would help researchers and operational decision makers better assess the intensification, evolutionary state, and severe weather potential of thunderstorms. This work supports risk reduction activities presently underway for the future launch of the GOES-R Geostationary Lightning Mapper (GLM).
Algorithms for Lunar Flash Video Search, Measurement, and Archiving
NASA Technical Reports Server (NTRS)
Swift, Wesley; Suggs, Robert; Cooke, Bill
2007-01-01
Lunar meteoroid impact flashes provide a method to estimate the flux of the large meteoroid flux and thus their hazard to spacecraft. Although meteoroid impacts on the Moon have been detected using video methods for over a decade, the difficulty of manually searching hours of video for the rare, extremely brief impact flashes has discouraged the technique's systematic implementation. A prototype has been developed for the purpose of automatically searching lunar video records for impact flashes, eliminating false detections, editing the returned possible flashes, Z and archiving and documenting the results. The theory and organization of the program is discussed with emphasis on the filtering out of several classes of false detections and retaining the brief portions of the raw video necessary for in depth analysis of the flashes detected. Several utilities for measurement, analysis, and location of the flashes on the moon included in the program are demonstrated. Application of the program to a year's worth of lunar observations is discussed along with examples of impact flashes as well as several classes of false impact flashes.
Algorithms for Lunar Flash Video Search, Measurement, and Archiving
NASA Technical Reports Server (NTRS)
Swift, Wesley; Suggs, Robert; Cooke, William
2007-01-01
Lunar meteoroid impact flashes provide a method to estimate the flux of the large meteoroid flux and thus their hazard to spacecraft. Although meteoroid impacts on the Moon have been detected using video methods for over a decade, the difficulty of manually searching hours of video for the rare, extremely brief impact flashes has discouraged the technique's systematic implementation. A prototype has been developed for the purpose of automatically searching Lunar video records for impact flashes, eliminating false detections, editing the returned possible flashes, and archiving and documenting the results. The theory and organization of the program is discussed with emphasis on the filtering out of several classes of false detections and retaining the brief portions of the raw video necessary for in depth analysis of the flashes detected. Several utilities for measurement, analysis, and location of the flashes on the moon included in the program are demonstrated. Application of the program to a year's worth of Lunar observations is discussed along with examples of impact flashes as well as several classes of false impact flashes.
NASA Astrophysics Data System (ADS)
Akita, Manabu; Yoshida, Satoru; Nakamura, Yoshitaka; Morimoto, Takeshi; Ushio, Tomoo; Kawasaki, Zen-Ichiro; Wang, Daohong
Lightning Research Group of Osaka University (LRG-OU) has been developing and improving the VHF broadband digital interferometer (DITF) for thunderstorm observations. It enables us to locate the impulsive VHF radiation sources caused by lightning discharges with extremely high resolutions. As a result of the VHF observations during the 2007-2008 winter season in the Japan Sea coastal area, cloud-to-ground (CG) flashes that neutralize multiple charge regions inside thunderclouds are visualized by the VHF broadband DITF. The first flash is the positive CG flash that neutralizes multiple positive charge regions in a flash. The second flash is the bipolar lightning flash that neutralizes both positive and negative charge inside thunderclouds. In the case of bipolar lightning flashes, some tens millisecond after the return strokes, the subsequent negative breakdowns initiate from the proximities of the initiation points of the preceding negative stepped leaders. It was also found that the altitudes of negative charge regions are lower than 2km. The bipolar lightning flashes observed in this campaign neutralize positive charge after lowering the negative charge to the ground.
Two-flash thresholds as a function of flash luminance and area.
DOT National Transportation Integrated Search
1968-09-01
The recent use of strobe lights in aviation suggests the possibility of using temporal patterns of short duration flashes as information-carrying signals. Under night flight conditions, two-flash thresholds were obtained using a two-interval, tempora...
... Arabic (العربية) Expand Section Floods and Flash Flooding - English PDF Floods and Flash Flooding - العربية (Arabic) PDF ... Bosnian (bosanski) Expand Section Floods and Flash Flooding - English PDF Floods and Flash Flooding - bosanski (Bosnian) PDF ...
Sharma, Priya; Sridhar, Jayanth; Mehta, Sonia
2015-09-01
Flashes and floaters are common ocular complaints. Flashes refer to aberrations of light that are seen in a patient's field of gaze. The flashes can be of varying sizes, colors, frequency, and durations, depending on the cause. Floaters are another common visual phenomenon caused by particles or debris in the vitreous gel of the eye that cause shadows and thus visual changes, especially against bright backgrounds and in brightly lit environments. Flashes and floaters can occur individually or together. This article discusses common causes of flashes and floaters to help with the triaging and management of these patients. Copyright © 2015 Elsevier Inc. All rights reserved.
The Evolution and Structure of Extreme Optical Lightning Flashes
Peterson, Michael; Rudlosky, Scott; Deierling, Wiebke
2018-01-01
This study documents the composition, morphology, and motion of extreme optical lightning flashes observed by the Lightning Imaging Sensor (LIS). The furthest separation of LIS events (groups) in any flash is 135 km (89 km), the flash with the largest footprint had an illuminated area of 10,604 km2, and the most dendritic flash has 234 visible branches. The longest-duration convective LIS flash lasted 28 s and is overgrouped and not physical. The longest-duration convective-to-stratiform propagating flash lasted 7.4 s, while the longest-duration entirely stratiform flash lasted 4.3 s. The longest series of nearly consecutive groups in time lasted 242 ms. The most radiant recorded LIS group (i.e., “superbolt”) is 735 times more radiant than the average group. Factors that impact these optical measures of flash morphology and evolution are discussed. While it is apparent that LIS can record the horizontal development of the lightning channel in some cases, radiative transfer within the cloud limits the flash extent and level of detail measured from orbit. These analyses nonetheless suggest that lightning imagers such as LIS and Geostationary Lightning Mapper can complement ground-based lightning locating systems for studying physical lightning phenomena across large geospatial domains. PMID:29527425
NASA Technical Reports Server (NTRS)
Mach, Douglas M.; Christian, Hugh J.; Blakeslee, Richard; Boccippio, Dennis J.; Goodman, Steve J.; Boeck, William
2006-01-01
We describe the clustering algorithm used by the Lightning Imaging Sensor (LIS) and the Optical Transient Detector (OTD) for combining the lightning pulse data into events, groups, flashes, and areas. Events are single pixels that exceed the LIS/OTD background level during a single frame (2 ms). Groups are clusters of events that occur within the same frame and in adjacent pixels. Flashes are clusters of groups that occur within 330 ms and either 5.5 km (for LIS) or 16.5 km (for OTD) of each other. Areas are clusters of flashes that occur within 16.5 km of each other. Many investigators are utilizing the LIS/OTD flash data; therefore, we test how variations in the algorithms for the event group and group-flash clustering affect the flash count for a subset of the LIS data. We divided the subset into areas with low (1-3), medium (4-15), high (16-63), and very high (64+) flashes to see how changes in the clustering parameters affect the flash rates in these different sizes of areas. We found that as long as the cluster parameters are within about a factor of two of the current values, the flash counts do not change by more than about 20%. Therefore, the flash clustering algorithm used by the LIS and OTD sensors create flash rates that are relatively insensitive to reasonable variations in the clustering algorithms.
NASA Astrophysics Data System (ADS)
Morss, Rebecca E.; Mulder, Kelsey J.; Lazo, Jeffrey K.; Demuth, Julie L.
2016-10-01
This study investigates flash flood forecast and warning communication, interpretation, and decision making, using data from a survey of 418 members of the public in Boulder, Colorado, USA. Respondents to the public survey varied in their perceptions and understandings of flash flood risks in Boulder, and some had misconceptions about flash flood risks, such as the safety of crossing fast-flowing water. About 6% of respondents indicated consistent reversals of US watch-warning alert terminology. However, more in-depth analysis illustrates the multi-dimensional, situationally dependent meanings of flash flood alerts, as well as the importance of evaluating interpretation and use of warning information along with alert terminology. Some public respondents estimated low likelihoods of flash flooding given a flash flood warning; these were associated with lower anticipated likelihood of taking protective action given a warning. Protective action intentions were also lower among respondents who had less trust in flash flood warnings, those who had not made prior preparations for flash flooding, and those who believed themselves to be safer from flash flooding. Additional analysis, using open-ended survey questions about responses to warnings, elucidates the complex, contextual nature of protective decision making during flash flood threats. These findings suggest that warnings can play an important role not only by notifying people that there is a threat and helping motivate people to take protective action, but also by helping people evaluate what actions to take given their situation.
NAND FLASH Radiation Tolerant Intelligent Memory Stack (RTIMS FLASH)
NASA Astrophysics Data System (ADS)
Sellier, Charles; Wang, Pierre
2014-08-01
The NAND Flash Radiation Tolerant and Intelligent Memory Stack (RTIMS FLASH) is a User's Friendly, Plug-and- Play and Radiation Protected high density NAND Flash Memory. It provides a very high density, radiation hardened by design and non-volatile memory module suitable for all space applications such as commercial or scientific geo-stationary missions, earth observation, navigation, manned space vehicles and deep space scientific exploration. The Intelligent Memory Module embeds a very high density of non-volatile NAND Flash memory and one Intelligent Flash Memory Controller (FMC). The FMC provides the module with a full protection against the radiation effects such as SEL, SEFI and SEU. It's also granting the module with bad block immunity as well as high level service functions that will benefit to the user's applications.
Characteristic pulse trains of preliminary breakdown in four isolated small thunderstorms
NASA Astrophysics Data System (ADS)
Ma, Dong
2017-03-01
Using a low-frequency six-station local network, preliminary breakdown (PB) pulses not followed or followed by negative return stroke (RS), which are defined as PB-type and PB cloud-to-ground (PBCG)-type flashes, are analyzed based on four isolated small thunderstorms for the first time. On the basis of 22 PB-type flashes out of totally 2155 flashes, it indicates that the number of PB-type flashes is very small. At the early stage, PB-type flashes are observed in all four thunderstorms. At the active stage, PB-type flashes still can occur; meanwhile, there are few or no negative cloud-to-ground (CG) flashes. However, at the final stage no PB-type flashes occur. At the stage of distinct cell merging or splitting, PB-type flashes are also observed. Based on the 123 PBCG-type flashes, we discuss the percentage of PBCG-type flashes and also analyze the relationship between the electric field (E-field) amplitude of the largest pulse in the PB pulse train normalized to 100 km (PBA), the E-field amplitude of the first return stroke normalized to 100 km (RSA), the time interval between PBA and RSA (PB-RS interval), and the ratio between PBA and RSA (PB-RS ratio). We find that the percentage of PBCG-type flashes is not always dependent on PBA or PB-RS ratio; the type of thunderstorms may also have an impact on this percentage. None of the PB-RS intervals is less than 20 ms; we speculate that such long PB-RS interval is the feature of isolated small thunderstorms, but more observations are needed to further investigate this question.
Federici, Lauren M.; Roth, Sarah Dorsey; Krier, Connie; Fitz, Stephanie D.; Skaar, Todd; Shekhar, Anantha; Carpenter, Janet S.; Johnson, Philip L.
2016-01-01
Objective Since longitudinal studies determined that anxiety is a strong risk factor for hot flashes, we hypothesized that an anxiogenic stimulus that signals air hunger (hypercapnic, normoxic gas) would trigger an exacerbated hot flash-associated increase in tail skin temperature (TST) in a rat ovariectomy (OVEX) model of surgical menopause and hot flashes in symptomatic menopausal women. We also assessed TST responses in OVEX serotonin transporter (SERT)+/− rats that models a common polymorphism that is associated with increased climacteric symptoms in menopausal women and increases in anxiety traits. Methods OVEX and sham-OVEX rats (initial experiment) and wildtype and SERT+/− OVEX rats (subsequent experiment) were exposed to a 5 min infusion of 20%CO2 normoxic gas while measuring TST. Menopausal women were given brief 20% and 35%CO2 challenges, and hot flashes were self-reported and objectively verified. Results Compared to controls, OVEX rats had exacerbated increases in TST, and SERT+/− OVEX rats had prolonged TST increases following CO2. Most women reported mild/moderate hot flashes after CO2 challenges, and the hot flash severity to CO2 was positively correlated with daily hot flash frequency. Conclusions The studies demonstrate that this anxiogenic stimulus is capable of inducing cutaneous vasomotor responses in OVEX rats, and eliciting hot flashes in menopausal women. In rats, the severity of the response was mediated by loss of ovarian function and increased anxiety traits (SERT+/−), and, in women, by daily hot flash frequency. These findings may provide insights into anxiety related triggers and genetic risk factors for hot flashes in thermoneutral environments. PMID:27465717
Huang, Alison J; Cummings, Steven R; Schembri, Michael; Vittinghoff, Eric; Ganz, Peter; Grady, Deborah
2016-03-01
To describe the efficacy and tolerability of continuous nitroglycerin for treatment of hot flashes. Perimenopausal and postmenopausal women reporting at least seven hot flashes per day were recruited into a single-arm, dose-escalation trial of continuous transdermal nitroglycerin. Participants were started on a generic 0.1 mg/hour nitroglycerin patch applied daily without patch-free periods. During 4 weeks, participants escalated dosage weekly to 0.2, 0.4, or 0.6 mg/hour as tolerated, then discontinued nitroglycerin during the final week. Changes in hot flash frequency and severity were assessed using symptom diaries. Paired t tests examined change in outcomes between baseline and maximal-dose therapy and after discontinuation of nitroglycerin. Of the 19 participants, mean age was 51.4 (±4.3) years. Women reported an average 10.6 (±3.0) hot flashes and 7.1 (±3.8) moderate-to-severe hot flashes per day at baseline. Eleven women escalated to 0.6 mg/hour, three to 0.4 mg/hour, two to 0.2 mg/hour, and one remained on 0.1 mg/hour nitroglycerin. Two discontinued nitroglycerin before the first outcomes assessment. Among the remaining 17 women, the average daily frequency of hot flashes decreased by 54% and the average frequency of moderate-to-severe hot flashes decreased by 69% from baseline to maximum-dose therapy (P < 0.001 for both). After discontinuing nitroglycerin, participants reported an average 23% increase in frequency of any hot flashes (P = 0.041) and 96% increase in moderate-to-severe hot flashes (P < 0.001). Continuous nitroglycerin may substantially and reversibly decrease hot flash frequency and severity. If confirmed in a randomized blinded trial, it may offer a novel nonhormonal hot flash treatment.
Huang, Alison J.; Cummings, Steven R.; Schembri, Michael; Vittinghoff, Eric; Ganz, Peter; Grady, Deborah
2015-01-01
Objective To describe the efficacy and tolerability of continuous nitroglycerin for treatment of hot flashes. Methods Peri- and postmenopausal women reporting at least 7 hot flashes per day were recruited into a single-arm, dose-escalation trial of continuous transdermal nitroglycerin. Participants were started on a generic 0.1 mg/hr nitroglycerin patch applied daily without patch-free periods. Over four weeks, participants escalated dosage weekly to 0.2, 0.4, or 0.6 mg/hr as tolerated, then discontinued nitroglycerin during the final week. Changes in hot flash frequency and severity were assessed using symptom diaries. Paired t-tests examined change in outcomes between baseline and maximal-dose therapy as well as after discontinuation of nitroglycerin. Results Of the 19 participants, mean age was 51.4 (±4.3) years. Women reported an average 10.6 (±3.0) hot flashes and 7.1 (±3.8) moderate-to-severe hot flashes per day at baseline. Eleven women escalated to 0.6 mg/hr, three to 0.4 mg/hr, two to 0.2 mg/hr, and one remained on 0.1 mg/hr nitroglycerin. Two discontinued nitroglycerin before the first outcomes assessment. Among the remaining 17 women, the average daily frequency of hot flashes decreased by 54% and the average frequency of moderate-to-severe hot flashes decreased by 69% from baseline to maximum-dose therapy (P<0.001 for both). After discontinuing nitroglycerin, participants reported an average 23% increase in frequency of any hot flashes (P=0.041) and 96% increase in moderate-to-severe hot flashes (P<0.001). Conclusions Continuous nitroglycerin may substantially and reversibly decrease hot flash frequency and severity. If confirmed in a randomized blinded trial, it may offer a novel non-hormonal hot flash treatment. PMID:26263283
Freeman, Ellen W; Sammel, Mary D; Sanders, Richard J
2014-09-01
This study aims to estimate the risk of hot flashes relative to natural menopause and to evaluate the associations of hormone levels, behavioral variables, and demographic variables with the risk of hot flashes after menopause. We performed annual assessment of 255 women who were premenopausal at baseline and reached natural menopause within 16 years of follow-up. The prevalence of moderate/severe hot flashes increased in each premenopausal year, reaching a peak of 46% in the first 2 years after the final menstrual period (FMP). Hot flashes decreased slowly after menopause and did not return to premenopausal levels until 9 years after the FMP. The mean (SD) duration of moderate/severe hot flashes after the FMP was 4.6 (2.9) years (for any hot flashes, 4.9 [3.1] y). One third of women at 10 years or more after menopause continued to experience moderate/severe hot flashes. African-American women (obese and nonobese) and obese white women had significantly greater risks of hot flashes compared with nonobese white women (interaction, P = 0.01). In multivariable analysis, increasing follicle-stimulating hormone levels before the FMP (P < 0.001), decreasing estradiol (odds ratio, 0.87; 95% CI, 0.78-0.96; P = 0.008), and increasing anxiety (odds ratio, 1.05; 95% CI, 1.03-1.06; P < 0.001) were significant risk factors for hot flashes, whereas higher education levels were protective (odds ratio, 0.66; 95% CI, 0.47-0.91; P = 0.011). Moderate/severe hot flashes continue, on average, for nearly 5 years after menopause; more than one third of women observed for 10 years or more after menopause have moderate/severe hot flashes. Continuation of hot flashes for more than 5 years after menopause underscores the importance of determining individual risks/benefits when selecting hormone or nonhormone therapy for menopausal symptoms.
RISK OF LONG TERM HOT FLASHES AFTER NATURAL MENOPAUSE: EVIDENCE FROM THE PENN OVARIAN AGING COHORT
Freeman, Ellen W.; Sammel, Mary D.; Sanders, Richard J.
2015-01-01
Objectives To estimate the risk of hot flashes relative to natural menopause and evaluate associations of hormone levels, behavioral and demographic variables with the risk of hot flashes following menopause. Methods Annual assessments of 255 women who were premenopausal at baseline and reached natural menopause during 16 years of follow-up. Results The prevalence of moderate/severe hot flashes increased in each premenopausal year, reaching a peak of 46% in the first two years after the final menstrual period (FMP). Hot flashes decreased slowly following menopause and did not return to premenopausal levels until 9 years after FMP. The mean duration of moderate/severe hot flashes after FMP was 4.6 (SD2.9) years (4.9, SD3.1 years for any hot flashes). One-third of women at 10 or more years following menopause continued to experience moderate/severe hot flashes. African American women (obese and non-obese) and obese white women had significantly greater risk of hot flashes compared to non-obese white women (interaction P=0.01). In multivariable analysis, increasing FSH levels before FMP (P<0.001), decreasing estradiol (OR 0.87, 95% CI: 0.78–0.96, P=0.008), and increasing anxiety (OR 1.05, 95% CI: 1.03–1.06, P<0.001) were significant risk factors for hot flashes, while higher education levels were protective (OR 0.66, 95% CI: 0.47–0.91, P=0.011). Conclusions Moderate/severe hot flashes continued on average for nearly 5 years following menopause; more than one- third of women observed for 10 or more years following menopause had moderate/severe hot flashes. Continuation of hot flashes for more than 5 years following menopause underscores the importance of determining individual risk/benefit when selecting hormone or non-hormonal therapy for menopausal symptoms. PMID:24473530
De Cola, A; Bongiorno-Borbone, L; Bianchi, E; Barcaroli, D; Carletti, E; Knight, R A; Di Ilio, C; Melino, G; Sette, C; De Laurenzi, V
2012-02-02
Replication-dependent histone gene expression is a fundamental process occurring in S-phase under the control of the cyclin-E/CDK2 complex. This process is regulated by a number of proteins, including Flice-Associated Huge Protein (FLASH) (CASP8AP2), concentrated in specific nuclear organelles known as HLBs. FLASH regulates both histone gene transcription and mRNA maturation, and its downregulation in vitro results in the depletion of the histone pull and cell-cycle arrest in S-phase. Here we show that the transcription factor p73 binds to FLASH and is part of the complex that regulates histone gene transcription. Moreover, we created a novel gene trap to disrupt FLASH in mice, and we show that homozygous deletion of FLASH results in early embryonic lethality, owing to arrest of FLASH(-/-) embryos at the morula stage. These results indicate that FLASH is an essential, non-redundant regulator of histone transcription and cell cycle during embryogenesis.
A pilot study of magnetic therapy for hot flashes after breast cancer.
Carpenter, Janet S; Wells, Nancy; Lambert, Beth; Watson, Peggy; Slayton, Tami; Chak, Bapsi; Hepworth, Joseph T; Worthington, W Bradley
2002-04-01
The purpose of this randomized placebo-controlled crossover pilot study was to evaluate the effectiveness and acceptability of magnetic therapy for hot flashes among breast cancer survivors. Participants completed a 24-hour baseline hot-flash monitoring session, wore the magnetic devices or placebo for 3 days, completed an after-treatment hot-flash monitoring session, experienced a 10-day washout period, and then crossed over to the opposite study arm. Magnetic devices and placebos were placed on 6 acupressure sites corresponding to hot-flash relief. Complete data were available from 11 survivors of breast cancer. Results indicated magnetic therapy was no more effective than placebo in decreasing hot-flash severity, and contrary to expectations, placebo was significantly more effective than magnets in decreasing hot-flash frequency, bother, interference with daily activities, and overall quality of life. Implications for clinical practice and future research include the need to explore alternative interventions aimed at alleviating hot flashes in this population.
Obtaining the Grobner Initialization for the Ground Flash Fraction Retrieval Algorithm
NASA Technical Reports Server (NTRS)
Solakiewicz, R.; Attele, R.; Koshak, W.
2011-01-01
At optical wavelengths and from the vantage point of space, the multiple scattering cloud medium obscures one's view and prevents one from easily determining what flashes strike the ground. However, recent investigations have made some progress examining the (easier, but still difficult) problem of estimating the ground flash fraction in a set of N flashes observed from space In the study by Koshak, a Bayesian inversion method was introduced for retrieving the fraction of ground flashes in a set of flashes observed from a (low earth orbiting or geostationary) satellite lightning imager. The method employed a constrained mixed exponential distribution model to describe the lightning optical measurements. To obtain the optimum model parameters, a scalar function of three variables (one of which is the ground flash fraction) was minimized by a numerical method. This method has formed the basis of a Ground Flash Fraction Retrieval Algorithm (GoFFRA) that is being tested as part of GOES-R GLM risk reduction.
Fast repetition rate (FRR) flasher
Kolber, Zbigniew; Falkowski, Paul
1997-02-11
A fast repetition rate (FRR) flasher suitable for high flash photolysis including kinetic chemical and biological analysis. The flasher includes a power supply, a discharge capacitor operably connected to be charged by the power supply, and a flash lamp for producing a series of flashes in response to discharge of the discharge capacitor. A triggering circuit operably connected to the flash lamp initially ionizes the flash lamp. A current switch is operably connected between the flash lamp and the discharge capacitor. The current switch has at least one insulated gate bipolar transistor for switching current that is operable to initiate a controllable discharge of the discharge capacitor through the flash lamp. Control means connected to the current switch for controlling the rate of discharge of the discharge capacitor thereby to effectively keep the flash lamp in an ionized state between Successive discharges of the discharge capacitor. Advantageously, the control means is operable to discharge the discharge capacitor at a rate greater than 10,000 Hz and even up to a rate greater than about 250,000 Hz.
Statistical Evolution of the Lightning Flash
NASA Astrophysics Data System (ADS)
Zoghzoghy, F. G.; Cohen, M.; Said, R.; Inan, U. S.
2012-12-01
Natural lightning is one of the most fascinating and powerful electrical processes on Earth. To date, the physics behind this natural phenomenon are not fully understood, due primarily to the difficulty of obtaining measurements inside thunderstorms and to the wide range of timescales involved (from nanoseconds to seconds). Our aim is to use accurate lightning geo-location data from the National Lightning Detection Network (NLDN) to study statistical patterns in lightning, taking advantage of the fact that millions of lightning flashes occur around the globe every day. We present two sets of results, one involving the patterns of flashes in a storm, and a second involving the patterns of strokes in a flash. These patterns can provide a surrogate measure of the timescales and the spatial extents of the underlying physical processes. First, we study the timescales of charge buildup inside thunderstorms. We find that, following a lightning flash, the probability of another neighboring flash decreases and takes tens of seconds to recover. We find that this suppression effect is a function of flash type, stroke peak current, cloud-to-ground (CG) stroke multiplicity, and other lightning and geographical parameters. We find that the probabilities of subsequent flashes are more suppressed following oceanic lightning, or following flashes with higher peak currents and/or higher multiplicities (for CG flashes). Second, we use NLDN data to study the evolution of the strokes within a CG flash. A CG flash typically includes multiple return strokes, which can occur in the same channel or in multiple channels within a few kilometers. We cluster NLDN stroke data into flashes and produce the probability density function of subsequent strokes as a function of distance and time-delays relative to the previous stroke. Using this technique, we investigate processes which occur during the CG lightning flash with nanosecond to millisecond timescales. For instance, our results suggest that subsequent strokes that occur in a newly formed channel follow a pattern that propagates at a speed of ~200 km/s. We present our statistical techniques and discuss more thoroughly our work and results.
Huang, Wan-Yu; Chang, Chia-Chu; Chen, Dar-Ren; Kor, Chew-Teng; Chen, Ting-Yu; Wu, Hung-Ming
2017-01-01
Introduction Hot flashes have been postulated to be linked to the development of metabolic disorders. This study aimed to evaluate the relationship between hot flashes, adipocyte-derived hormones, and insulin resistance in healthy, non-obese postmenopausal women. Participants and design In this cross-sectional study, a total of 151 women aged 45–60 years were stratified into one of three groups according to hot-flash status over the past three months: never experienced hot flashes (Group N), mild-to-moderate hot flashes (Group M), and severe hot flashes (Group S). Variables measured in this study included clinical parameters, hot flash experience, fasting levels of circulating glucose, lipid profiles, plasma insulin, and adipocyte-derived hormones. Multiple linear regression analysis was used to evaluate the associations of hot flashes with adipocyte-derived hormones, and with insulin resistance. Settings The study was performed in a hospital medical center. Results The mean (standard deviation) of body-mass index was 22.8(2.7) for Group N, 22.6(2.6) for Group M, and 23.5(2.4) for Group S, respectively. Women in Group S displayed statistically significantly higher levels of leptin, fasting glucose, and insulin, and lower levels of adiponectin than those in Groups M and N. Multivariate linear regression analysis revealed that hot-flash severity was significantly associated with higher leptin levels, lower adiponectin levels, and higher leptin-to-adiponectin ratio. Univariate linear regression analysis revealed that hot-flash severity was strongly associated with a higher HOMA-IR index (% difference, 58.03%; 95% confidence interval, 31.00–90.64; p < 0.001). The association between hot flashes and HOMA-IR index was attenuated after adjusting for leptin or adiponectin and was no longer significant after simultaneously adjusting for leptin and adiponectin. Conclusion The present study provides evidence that hot flashes are associated with insulin resistance in postmenopausal women. It further suggests that hot flash association with insulin resistance is dependent on the combination of leptin and adiponectin variables. PMID:28448547
Pachman, Deirdre R; Jones, Jason M; Loprinzi, Charles L
2010-01-01
Hot flashes are one of the most common and distressing symptoms associated with menopause, occurring in more than 75% of postmenopausal women. They are especially problematic in breast cancer patients since some breast cancer therapies can induce hot flashes. For mild hot flashes, it is proposed that behavioral modifications are the first step in management. Hormonal therapies, including estrogens and progestogens, are the most well known effective agents in relieving hot flashes; however, the safety of these agents is controversial. There is an increasing amount of literature on nonhormonal agents for the treatment of hot flashes. The most promising data regard newer antidepressant agents such as venlafaxine, which reduces hot flashes by about 60%. Gabapentin is another nonhormonal agent that is effective in reducing hot flashes. While many complimentary therapies, including phytoestrogens, black cohosh, and dehydroepiandrosterone, have been explored for the treatment of hot flashes; none can be recommended at this time. Furthermore, there is a lack of strong evidence to support exercise, yoga, or relaxation for the treatment of hot flashes. Paced respirations and hypnosis appear to be promising enough to warrant further investigation. Another promising nonpharmacological therapy, currently under investigation, involves a stellate ganglion block. PMID:21072305
GLM Validation Studies in Colorado
NASA Astrophysics Data System (ADS)
Rutledge, S. A.; Reimel, K.; Fuchs, B.; Xu, W.
2017-12-01
On 8 May 2017 the Geostationary Lightning Mapper (GLM) calibration/validation field campaign completed a mission over the domain of the Colorado Lightning Mapping Array (LMA). This "gold mine day" produced a mixture of normal polarity and anomalous storms of varying intensity. A case study analysis has been completed for a portion of three individual storms from this day. By utilizing a cell tracking algorithm and lightning flash attribution program, individual lightning flashes detected by the GLM, LMA, the National Lightning Detection Network (NLDN), and Earth Networks Total Lightning Network (ENTLN) are attributed to individual storm cells. The focus of this analysis is the detection efficiency of GLM. We will discuss how the GLM detection efficiency changes as a result of storm morphology and lightning flash characteristics. Lightning flash size, flash height, and the amount of ice present between the lightning flash altitude and the top of the cloud all appear to play a role in how well GLM detects lightning flashes. Since GLM shares the same concept as its predecessor TRMM LIS (optically-based lightning detection), the evaluation of TRMM LIS against LMA network-detected lightning provides insights into the GLM detection efficiency. We have collected observations by LIS and LMA coincident in time and space during 2008-2014. The sample includes 400 LIS overpasses with both LIS and LMA detecting flashes within 150 km radius of the center of the LMA array during the 120 second LIS observing time period (analysis presently confined to the Alabama LMA network). The overall LIS detection efficiency (DE, defined as the ratio of flash rates between LIS and LMA) is 0.45, with higher DE for lower flash rate cases. LIS showed a DE of nearly 100% for cases with flash rates < 10 fl/min, but had a DE of only 20-30% for high flash rates within intense storms (> 300 fl/min). We further separated the dataset into day and night, and found that the night-time DE (0.6) increased by 20% compared to day-time DE (0.5). LIS DE also increased as a function of LMA-derived flash size, possibly due to stronger radiance from larger flashes. LIS DE was the lowest ( 40%) for flashes with sizes smaller than a single LIS pixel (< 16 km2). These results may be applicable to GLM as well.
Clinical Hypnosis in the Treatment of Post-Menopausal Hot Flashes: A Randomized Controlled Trial
Elkins, Gary R.; Fisher, William I.; Johnson, Aimee K.; Carpenter, Janet S.; Keith, Timothy Z.
2012-01-01
Objective The use of estrogen and progesterone to manage vasomotor symptoms (i.e., hot flashes, night sweats) has declined due to concerns over their risks and there is an increased interest in alternate, effective, and low-risk treatments. This study reports the results of a randomized, controlled trial of clinical hypnosis in treating vasomotor symptoms among post-menopausal women. Methods Randomized, single-blind, controlled, clinical trial involving 187 post-menopausal women reporting a minimum of seven hot flashes per day, or at least 50 hot flashes a week at baseline between December 2008 and April 2012. Eligible participants received five weekly sessions of either clinical hypnosis or structured-attention control. Primary outcomes were hot flash frequency (subjectively and physiologically recorded) and hot flash score assessed by daily diaries at weeks 2–6, and 12. Secondary outcomes included measures of hot flash related daily interference, sleep quality and treatment satisfaction. Results In a modified intent-to-treat analysis that included all randomized participants that provided data, reported subjective hot flash frequency from baseline to week 12 showed a mean reduction of 55.82 hot flashes for the clinical hypnosis intervention (74.16%), versus a 12.89 hot flash reduction (17.13%) for the control (p<.001, 95% CI, 36.15–49.67). Mean reduction in hot flash score was 18.83 (80.32%) for the clinical hypnosis intervention as compared to 3.53 (15.38%) for the control (p<.001, 95% CI, 12.60–17.54). At 12 week follow-up, the mean reduction in physiologically monitored hot flashes was 5.92 (56.86%) for clinical hypnosis and .88 (9.94%) for the control (p<.001, 95% CI, 2.00–5.46). Secondary outcomes were significantly improved compared to control at 12 week follow-up in hot flash related interference (p<.001, 95% CI, 2.74–4.02), sleep quality (p<.001, 95% CI, 3.65–5.84), and treatment satisfaction (p<.001, 95% CI, 7.79–8.59). Conclusion Compared to a structured attention control, clinical hypnosis resulted in significant reductions in self-reported and physiologically measured hot flashes as well as hot flash scores in post-menopausal women. PMID:23435026
DOT National Transportation Integrated Search
2013-08-01
During late-night flash (LNF) mode (from late night to early morning hours), traffic signals flash yellow for one road (typically, the major road), requiring caution but no stopping, and flash red for the other road (typically, the minor road), requi...
Flash flood disasters analysis and evaluation: a case study of Yiyang County in China
NASA Astrophysics Data System (ADS)
Li, Haichen; Zhang, Xiaolei; Li, Qing; Qin, Tao; Lei, Xiaohui
2018-03-01
Global climate change leads to the more extreme precipitation and more flash flood disasters, which is a serious threat to the mountain inhabitants. To prevent flash flood disasters, China started flash flood disaster control planning and other projects from 2006. Among those measures, non-engineering measures are effective and economical. This paper introduced the framework of flash flood disaster analysis and evaluation in China, followed by a case study of Yiyang County.
Ng, Roger M K; Di Simplicio, Martina; McManus, Freda; Kennerley, Helen; Holmes, Emily A
2016-12-30
'Flash-forwards' - mental images of suicide - have been reported in selected Caucasian samples. Perceptions of defeat and entrapment are considered to be associated with suicidal ideation. We aimed to investigate (1) the presence of suicidal flash-forwards in people with recent suicidal ideation versus those without such ideation in an Asian sample, and (2) associations between suicidal flash-forwards, and perceptions of entrapment accounting for suicidal ideation. Eighty two suicidal and 80 non-suicidal participants from the Hong Kong Mental Morbidity Survey completed questionnaires including suicidal ideation, presence of suicidal flash-forward images, defeat and entrapment, at baseline and seven weeks later. Suicidal 'flash-forwards' were present only in suicidal cases. People with recent suicidal ideation and suicidal flash-forwards had more severe suicidal ideation than those without flash-forwards. Compared to those without suicidal ideation, people with recent suicidal ideation reported higher entrapment and defeat levels. Resolution of suicidal ideation over time was associated with fewer suicidal flash-forwards and reduced entrapment perceptions. At baseline and seven weeks, suicidal ideation was predicted by an interaction between suicidal flash-forwards presence and perceptions of entrapment. Mental imagery of suicide appears to be associated with suicidal ideation, and may represent a novel target in suicidal risk assessment and prevention. Copyright © 2016 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.
Hot flashes and midlife symptoms in relation to levels of salivary cortisol.
Gerber, Linda M; Sievert, Lynnette L; Schwartz, Joseph E
2017-02-01
This study examined the relationship between salivary cortisol levels and hot flashes during midlife. Previous studies have shown that cortisol levels increase with hot flashes in the laboratory, and higher cortisol levels have been associated with more severe hot flashes. Salivary cortisol levels were also examined in relation to total number of midlife symptoms. Women aged 40-60 years (n=109) reported the presence or absence of 23 symptoms, including hot flashes, during the previous 2 weeks. Salivary samples were collected at waking, 30min after waking, 1h before bedtime, and at bedtime. The cortisol awakening response (CAR), cortisol daily decline (CDD), log transformed salivary cortisol levels at each time point, and mean cortisol levels were compared by hot flash report using t-tests. Logistic regression analyses were performed to assess the association between each cortisol measure and the presence or absence of hot flashes, after controlling for potential covariates. Salivary cortisol levels were not significantly associated with hot flashes or sum of symptoms. Hot flash report did not differentiate women who had a positive CAR from those who did not, or women who showed strong CDD from those who did not. Symptomatic women - defined by hot flash report or symptom total - were not found to have higher salivary cortisol levels. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
ANXIETY AS A RISK FACTOR FOR MENOPAUSAL HOT FLASHES: EVIDENCE FROM THE PENN OVARIAN AGING COHORT
Freeman, Ellen W.; Sammel, Mary D.
2016-01-01
Objective The aim of this study was to identify temporal associations of anxiety dimensions with menopausal hot flashes in women progressing through the menopause transition. We hypothesized that associations of both somatic and affective dimensions of anxiety with hot flashes increased in the menopause transition, and that somatic anxiety was an independent risk factor for menopausal hot flashes. Methods Hot flashes, anxiety symptoms, hormone levels and other psychosocial variables were assessed annually for 14 years of follow-up. The 233 women were premenopausal at baseline and continued through one year or more after the final menstrual period. Anxiety dimensions were assessed with the Zung Anxiety Scale (ZAS), a validated measure of affective anxiety and somatic anxiety. Summed item scores were divided by the number of items rated, so that ranges of the two dimensions were comparable. Results Seventy-two percent of the sample reported moderate/severe hot flashes during the 14-year interval. There was no significant interaction between anxiety dimensions and menopausal stages. However, when adjusted for menopausal stage, the magnitude of association between somatic anxiety and hot flashes dramatically increased (OR 3.03, 95% CI: 2.12, 4.32, P<0.001), while the association between affective anxiety and hot flashes increased to a lesser extent (OR 1.27, 95% CI: 1.03, 1.57, P=0.024). Women with high levels of somatic anxiety (top third of the sample) had the greatest risk of hot flashes (P<0.001). When the anxiety dimensions were considered in combination, the additive effect of high affective anxiety symptoms was minimal, with no significant difference between the group with high affective/low somatic symptoms and the low symptom group in incident hot flashes at each menopausal stage (P=0.54). In multivariable analysis, somatic anxiety increased the risk of hot flashes more than 3 times (OR 3.13, 95% CI: 2.16, 4.53, P<0.001), but affective anxiety was not significantly associated with hot flashes after adjustment for other study variables (OR 1.19, 95% CI: 0.96, 1.48, P=0.117). Time-lagged somatic anxiety scores significantly predicted hot flashes, with a 71% increase in risk (OR 1.71, 95% CI: 1.21, 2.41, P=0.002). Time-lagged affective anxiety scores did not predict hot flashes, (OR 1.06, 95% CI: 0.87, 1.31, P=0.58). Conclusions This study showed a strong predictive association of somatic anxiety with the risk of menopausal hot flashes. The temporal associations suggest that somatic anxiety is not simply a redundant measure of hot flashes but predicts the risk of menopausal hot flashes and may be a potential target in clinical management of perimenopausal women. PMID:27433864
Positive cloud-to-ground lightning flashes in severe storms
NASA Technical Reports Server (NTRS)
Rust, W. D.; Macgorman, D. R.; Arnold, R. T.
1981-01-01
The occurrence of cloud-to-ground flashes that effectively lower positive charge to earth (+CG flash) over flat terrain has been documented in the mature stage of severe thunderstorms. Of the 31 documented +CG flashes, most had only one return stroke. Zero-to-peak rise times for the strokes averaged 7 microsec. The +CG flashes averaged 520 ms in duration, with 25 percent lasting more than 800 ms. Many of these had field changes suggestive of continuing current. Positive flashes have been observed to emanate from several regions of severe storms: high on the back of the main storm tower, through the wall cloud, and from the downshear anvil. Visually most of these positive flashes have emanated from high in the storm, and acoustic mapping of two shows thunder sources to a height of about 15 km.
Gun muzzle flash detection using a CMOS single photon avalanche diode
NASA Astrophysics Data System (ADS)
Merhav, Tomer; Savuskan, Vitali; Nemirovsky, Yael
2013-10-01
Si based sensors, in particular CMOS Image sensors, have revolutionized low cost imaging systems but to date have hardly been considered as possible candidates for gun muzzle flash detection, due to performance limitations, and low SNR in the visible spectrum. In this study, a CMOS Single Photon Avalanche Diode (SPAD) module is used to record and sample muzzle flash events in the visible spectrum, from representative weapons, common on the modern battlefield. SPADs possess two crucial properties for muzzle flash imaging - Namely, very high photon detection sensitivity, coupled with a unique ability to convert the optical signal to a digital signal at the source pixel, thus practically eliminating readout noise. This enables high sampling frequencies in the kilohertz range without SNR degradation, in contrast to regular CMOS image sensors. To date, the SPAD has not been utilized for flash detection in an uncontrolled environment, such as gun muzzle flash detection. Gun propellant manufacturers use alkali salts to suppress secondary flashes ignited during the muzzle flash event. Common alkali salts are compounds based on Potassium or Sodium, with spectral emission lines around 769nm and 589nm, respectively. A narrow band filter around the Potassium emission doublet is used in this study to favor the muzzle flash signal over solar radiation. This research will demonstrate the SPAD's ability to accurately sample and reconstruct the temporal behavior of the muzzle flash in the visible wavelength under the specified imaging conditions. The reconstructed signal is clearly distinguishable from background clutter, through exploitation of flash temporal characteristics.
Johns, Claire; Seav, Susan M; Dominick, Sally A; Gorman, Jessica R; Li, Hongying; Natarajan, Loki; Mao, Jun James; Irene Su, H
2016-04-01
Patient-centered decision making about hot flash treatments often incorporates a balance of efficacy and side effects in addition to patient preference. This systematic review examines randomized controlled trials (RCTs) comparing at least two non-hormonal hot flash treatments in breast cancer survivors. In July 2015, PubMed, SCOPUS, CINAHL, Cochrane, and Web of Science databases were searched for RCTs comparing active, non-hormonal hot flash treatments in female breast cancer survivors. Thirteen trials were included after identifying 906 potential studies. Four trials were dose comparison studies of pharmacologic treatments citalopram, venlafaxine, gabapentin, and paroxetine. Hot flash reduction did not differ by tamoxifen or aromatase inhibitor use. Citalopram 10, 20, and 30 mg daily had comparable outcomes. Venlafaxine 75 mg daily improved hot flashes without additional side effects from higher dosing. Gabapentin 900 mg daily improved hot flashes more than 300 mg. Paroxetine 10 mg daily had fewer side effects than 20 mg. Among four trials comparing different pharmacologic treatments, venlafaxine alleviated hot flash symptoms faster than clonidine; participants preferred venlafaxine over gabapentin. Five trials compared pharmacologic to non-pharmacologic treatments. Acupuncture had similar efficacy to venlafaxine and gabapentin but may have longer durability after completing treatment and fewer side effects. We could not perform a pooled meta-analysis because outcomes were not reported in comparable formats. Clinical trial data on non-hormonal hot flash treatments provide comparisons of hot flash efficacy and other patient important outcomes to guide clinical management. Clinicians can use the information to help patients select hot flash interventions.
Abdominal adiposity and hot flashes among midlife women.
Thurston, Rebecca C; Sowers, MaryFran R; Sutton-Tyrrell, Kim; Everson-Rose, Susan A; Lewis, Tené T; Edmundowicz, Daniel; Matthews, Karen A
2008-01-01
Two competing hypotheses suggest how adiposity may affect menopausal hot flashes. The "thin hypothesis" asserts that aromatization of androgens to estrogens in body fat should be associated with decreased hot flashes. Conversely, thermoregulatory models argue that body fat should be associated with increased hot flashes. The study objective was to examine associations between abdominal adiposity and hot flashes, including the role of reproductive hormones in these associations. The Study of Women's Health Across the Nation Heart Study (2001-2003) is an ancillary study to the Study of Women's Health Across the Nation, a community-based cohort study. Participants were 461 women (35% African American, 65% white) ages 45 to 58 years with an intact uterus and at least one ovary. Measures included a computed tomography scan to assess abdominal adiposity; reported hot flashes over the previous 2 weeks; and a blood sample for measurement of follicle-stimulating hormone, estradiol, and sex hormone-binding globulin-adjusted estradiol (free estradiol index). Associations were evaluated within multivariable logistic and linear regression models. Every 1-SD increase in total (odds ratio [OR]=1.28; 95% CI: 1.06-1.55) and subcutaneous (OR=1.30; 95% CI: 1.07-1.58) abdominal adiposity was associated with increased odds of hot flashes in age- and site-adjusted models. Visceral adiposity was not associated with hot flashes. Associations were not reduced when models included reproductive hormone concentrations. Increased abdominal adiposity, particularly subcutaneous adiposity, is associated with increased odds of hot flashes, favoring thermoregulatory models of hot flashes. Body fat may not protect women from hot flashes as once thought.
50 CFR 300.5 - Facilitation of enforcement.
Code of Federal Regulations, 2010 CFR
2010-10-01
... transmitted by flashing light directed at the vessel signaled. USCG units will normally use the flashing light..., flashing light, flags, whistle, horn or other means constitutes prima facie evidence of the offense of... International Code of Signals, may be sent by flashing light by an enforcement unit when conditions do not allow...
50 CFR 300.5 - Facilitation of enforcement.
Code of Federal Regulations, 2011 CFR
2011-10-01
... transmitted by flashing light directed at the vessel signaled. USCG units will normally use the flashing light..., flashing light, flags, whistle, horn or other means constitutes prima facie evidence of the offense of... International Code of Signals, may be sent by flashing light by an enforcement unit when conditions do not allow...
33 CFR 117.1007 - Elizabeth River-Eastern Branch.
Code of Federal Regulations, 2013 CFR
2013-07-01
... closing the draw, the channel traffic lights will change from flashing green to flashing red, the horn... down to vessels, the channel traffic lights will continue to flash red. (6) When the rail traffic has... opening to vessel traffic. During the opening swing movement, the channel traffic lights will flash red...
33 CFR 117.1007 - Elizabeth River-Eastern Branch.
Code of Federal Regulations, 2014 CFR
2014-07-01
... closing the draw, the channel traffic lights will change from flashing green to flashing red, the horn... down to vessels, the channel traffic lights will continue to flash red. (6) When the rail traffic has... opening to vessel traffic. During the opening swing movement, the channel traffic lights will flash red...
33 CFR 117.1007 - Elizabeth River-Eastern Branch.
Code of Federal Regulations, 2011 CFR
2011-07-01
... closing the draw, the channel traffic lights will change from flashing green to flashing red, the horn... down to vessels, the channel traffic lights will continue to flash red. (6) When the rail traffic has... opening to vessel traffic. During the opening swing movement, the channel traffic lights will flash red...
33 CFR 117.1007 - Elizabeth River-Eastern Branch.
Code of Federal Regulations, 2012 CFR
2012-07-01
... closing the draw, the channel traffic lights will change from flashing green to flashing red, the horn... down to vessels, the channel traffic lights will continue to flash red. (6) When the rail traffic has... opening to vessel traffic. During the opening swing movement, the channel traffic lights will flash red...
Decision support system for road closures in flash flood emergencies.
DOT National Transportation Integrated Search
2013-06-01
Among all the natural hazards, flash flood ranks as the No. 1 weather-related killer in U.S. More : than half of the deaths in flash flood are due to drowning victims in a traffic environment. So road : closure is critical to save lives from flash fl...
49 CFR 234.253 - Flashing light units and lamp voltage.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 4 2013-10-01 2013-10-01 false Flashing light units and lamp voltage. 234.253....253 Flashing light units and lamp voltage. (a) Each flashing light unit shall be inspected when... with installation specifications. (b) Lamp voltage shall be tested when installed and at least once...
49 CFR 234.253 - Flashing light units and lamp voltage.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 4 2012-10-01 2012-10-01 false Flashing light units and lamp voltage. 234.253....253 Flashing light units and lamp voltage. (a) Each flashing light unit shall be inspected when... with installation specifications. (b) Lamp voltage shall be tested when installed and at least once...
49 CFR 234.253 - Flashing light units and lamp voltage.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Flashing light units and lamp voltage. 234.253... Maintenance, Inspection, and Testing Inspections and Tests § 234.253 Flashing light units and lamp voltage. (a... proper alignment and frequency of flashes in accordance with installation specifications. (b) Lamp...
49 CFR 234.253 - Flashing light units and lamp voltage.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Flashing light units and lamp voltage. 234.253... Maintenance, Inspection, and Testing Inspections and Tests § 234.253 Flashing light units and lamp voltage. (a... proper alignment and frequency of flashes in accordance with installation specifications. (b) Lamp...
49 CFR 234.253 - Flashing light units and lamp voltage.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 4 2014-10-01 2014-10-01 false Flashing light units and lamp voltage. 234.253....253 Flashing light units and lamp voltage. (a) Each flashing light unit shall be inspected when... with installation specifications. (b) Lamp voltage shall be tested when installed and at least once...
Code of Federal Regulations, 2014 CFR
2014-07-01
..., nine inches high to indicate the vertical clearance under the closed draw at all stages of the tide... change from flashing green to flashing red anytime the bridge is not in the full open position. (10) During downward span movement, the channel traffic lights will change from flashing green to flashing red...
Code of Federal Regulations, 2012 CFR
2012-07-01
..., nine inches high to indicate the vertical clearance under the closed draw at all stages of the tide... change from flashing green to flashing red anytime the bridge is not in the full open position. (10) During downward span movement, the channel traffic lights will change from flashing green to flashing red...
Code of Federal Regulations, 2013 CFR
2013-07-01
..., nine inches high to indicate the vertical clearance under the closed draw at all stages of the tide... change from flashing green to flashing red anytime the bridge is not in the full open position. (10) During downward span movement, the channel traffic lights will change from flashing green to flashing red...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-07
... INTERNATIONAL TRADE COMMISSION [Docket No. 2971] Certain Flash Memory Chips and Products.... International Trade Commission has received a complaint entitled Certain Flash Memory Chips and Products... sale within the United States after importation of certain flash memory chips and products containing...
78 FR 55095 - Certain Flash Memory Chips and Products Containing Same; Institution of Investigation
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-09
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-893] Certain Flash Memory Chips and... States after importation of certain flash memory chips and products containing the same by reason of... sale within the United States after importation of certain flash memory chips and products containing...
49 CFR 234.217 - Flashing light units.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 4 2012-10-01 2012-10-01 false Flashing light units. 234.217 Section 234.217... light units. (a) Each flashing light unit shall be properly positioned and aligned and shall be visible to a highway user approaching the crossing. (b) Each flashing light unit shall be maintained to...
Galbraith, L.K.
1979-12-07
A controller provides a high voltage to maintain an electro-optic shutter in a transparent condition until a flash of light which would be harmful to personnel is sensed by a phototransistor. The controller then shorts the shutter to ground to minimize light transmission to the user and maintains light transmission at the pre-flash level for a predetermined time to allow the flash to subside. A log converter and differential trigger circuit keep the controller from being triggered by other light flashes which are not dangerous.
Galbraith, Lee K.
1981-01-01
A controller provides a high voltage to maintain an electro-optic shutter in a transparent condition until a flash of light which would be harmful to personnel is sensed by a phototransistor. The controller then shorts the shutter to ground to minimize light transmission to the user and maintains light transmission at the pre-flash level for a predetermined time to allow the flash to subside. A log converter and differential trigger circuit keep the controller from being triggered by other light flashes which are not dangerous.
Global optical lightning flash rates determined with the Forte satellite
DOE Office of Scientific and Technical Information (OSTI.GOV)
Light, T.; Davis, S. M.; Boeck, W. L.
2003-01-01
Using FORTE photodiode detector (PDD) observations of lightning, we have determined the geographic distribution of nighttime flash rate density. We estimate the PDD flash detection efficiency to be 62% for total lightning through comparison to lightning observations by the TRMM satellite's Lightning Imaging Sensor (LIS), using cases in which FORTE and TRMM viewed the same storm. We present here both seasonal and l,ot,al flash rate maps. We examine some characteristics of the optical emissions of lightning in both high and low flash rate environments, and find that while lightning occurs less frequently over ocean, oceanic lightning flashes are somewhat moremore » powerful, on average, than those over land.« less
The prediction of the flash point for binary aqueous-organic solutions.
Liaw, Horng-Jang; Chiu, Yi-Yu
2003-07-18
A mathematical model, which may be used for predicting the flash point of aqueous-organic solutions, has been proposed and subsequently verified by experimentally-derived data. The results reveal that this model is able to precisely predict the flash point over the entire composition range of binary aqueous-organic solutions by way of utilizing the flash point data pertaining to the flammable component. The derivative of flash point with respect to composition (solution composition effect upon flash point) can be applied to process safety design/operation in order to identify as to whether the dilution of a flammable liquid solution with water is effective in reducing the fire and explosion hazard of the solution at a specified composition. Such a derivative equation was thus derived based upon the flash point prediction model referred to above and then verified by the application of experimentally-derived data.
Thurston, Rebecca C; Hernandez, Javier; Del Rio, Jose M; De La Torre, Fernando
2011-07-01
Most midlife women have hot flashes. The conventional criterion (≥2 μmho rise/30 s) for classifying hot flashes physiologically has shown poor performance. We improved this performance in the laboratory with Support Vector Machines (SVMs), a pattern classification method. We aimed to compare conventional to SVM methods to classify hot flashes in the ambulatory setting. Thirty-one women with hot flashes underwent 24 h of ambulatory sternal skin conductance monitoring. Hot flashes were quantified with conventional (≥2 μmho/30 s) and SVM methods. Conventional methods had low sensitivity (sensitivity=.57, specificity=.98, positive predictive value (PPV)=.91, negative predictive value (NPV)=.90, F1=.60), with performance lower with higher body mass index (BMI). SVMs improved this performance (sensitivity=.87, specificity=.97, PPV=.90, NPV=.96, F1=.88) and reduced BMI variation. SVMs can improve ambulatory physiologic hot flash measures. Copyright © 2010 Society for Psychophysiological Research.
ERIC Educational Resources Information Center
Hanisch, Laura J.; Hantsoo, Liisa; Freeman, Ellen W.; Sullivan, Gregory M.; Coyne, James C.
2008-01-01
Despite decades of research, the causal mechanisms of hot flashes are not adequately understood, and a biopsychosocial perspective on hot flashes remains underdeveloped. This article explores overlooked parallels between hot flashes and panic attacks within 5 areas: course and symptomatology, physiological indicators, neurocircuitry and…
Phthalate metabolite levels and menopausal hot flashes in midlife women.
Ziv-Gal, Ayelet; Gallicchio, Lisa; Chiang, Catheryne; Ther, Sara N; Miller, Susan R; Zacur, Howard A; Dills, Russell L; Flaws, Jodi A
2016-04-01
During the menopausal transition, a woman's reproductive capacity declines, her hormone milieu changes, and her risk of hot flashes increases. Exposure to phthalates, which can be found in personal care products, can also result in altered reproductive function. Here, we investigated the associations between phthalate metabolite levels and midlife hot flashes. Eligible women (45-54 years of age) provided detailed information on hot flashes history and donated urine samples (n=195). Urinary phthalate metabolite levels were measured by HPLC-MS/MS. A higher total sum of phthalate metabolites commonly found in personal care products was associated with an increased risk of ever experiencing hot flashes (odds ratio (OR)=1.45; 95% confidence interval (CI)=1.07-1.96), hot flashes in the past 30days (OR=1.43; 95%CI=1.04-1.96), and more frequent hot flashes (OR=1.47; 95%CI=1.06-2.05). These data suggest that some phthalate exposures from personal care products are associated with menopausal hot flashes in women. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Koshak, William; Solakiewicz, Richard
2013-01-01
An analytic perturbation method is introduced for estimating the lightning ground flash fraction in a set of N lightning flashes observed by a satellite lightning mapper. The value of N is large, typically in the thousands, and the observations consist of the maximum optical group area produced by each flash. The method is tested using simulated observations that are based on Optical Transient Detector (OTD) and Lightning Imaging Sensor (LIS) data. National Lightning Detection NetworkTM (NLDN) data is used to determine the flash-type (ground or cloud) of the satellite-observed flashes, and provides the ground flash fraction truth for the simulation runs. It is found that the mean ground flash fraction retrieval errors are below 0.04 across the full range 0-1 under certain simulation conditions. In general, it is demonstrated that the retrieval errors depend on many factors (i.e., the number, N, of satellite observations, the magnitude of random and systematic measurement errors, and the number of samples used to form certain climate distributions employed in the model).
Phthalate metabolite levels and menopausal hot flashes in midlife women
Ziv-Gal, Ayelet; Gallicchio, Lisa; Chiang, Catheryne; Ther, Sara N.; Miller, Susan R.; Zacur, Howard A.; Dills, Russell L.; Flaws, Jodi A.
2016-01-01
During the menopausal transition, a woman’s reproductive capacity declines, her hormone milieu changes, and her risk of hot flashes increases. Exposure to phthalates, which can be found in personal-care products, can also result in altered reproductive function. Here, we investigated the associations between phthalate metabolite levels and midlife hot flashes. Eligible women (45–54 years of age) provided detailed information on hot flashes history and donated urine samples (n=195). Urinary phthalate metabolite levels were measured by HPLC-MS/MS. A higher total sum of phthalate metabolites commonly found in personal-care products was associated with an increased risk of ever experiencing hot flashes (odds ratio (OR)=1.45; 95% confidence interval (CI)= 1.07–1.96), hot flashes in the past 30 days (OR=1.43; 95%CI=1.04–1.96), and more frequent hot flashes (OR=1.47; 95%CI=1.06–2.05). These data suggest that some phthalate exposures from personal care products are associated with menopausal hot flashes in women. PMID:26867866
Fast repetition rate (FRR) flasher
Kolber, Z.; Falkowski, P.
1997-02-11
A fast repetition rate (FRR) flasher is described suitable for high flash photolysis including kinetic chemical and biological analysis. The flasher includes a power supply, a discharge capacitor operably connected to be charged by the power supply, and a flash lamp for producing a series of flashes in response to discharge of the discharge capacitor. A triggering circuit operably connected to the flash lamp initially ionizes the flash lamp. A current switch is operably connected between the flash lamp and the discharge capacitor. The current switch has at least one insulated gate bipolar transistor for switching current that is operable to initiate a controllable discharge of the discharge capacitor through the flash lamp. Control means connected to the current switch for controlling the rate of discharge of the discharge capacitor thereby to effectively keep the flash lamp in an ionized state between successive discharges of the discharge capacitor. Advantageously, the control means is operable to discharge the discharge capacitor at a rate greater than 10,000 Hz and even up to a rate greater than about 250,000 Hz. 14 figs.
Assessment of Vulnerability to Extreme Flash Floods in Design Storms
Kim, Eung Seok; Choi, Hyun Il
2011-01-01
There has been an increase in the occurrence of sudden local flooding of great volume and short duration caused by heavy or excessive rainfall intensity over a small area, which presents the greatest potential danger threat to the natural environment, human life, public health and property, etc. Such flash floods have rapid runoff and debris flow that rises quickly with little or no advance warning to prevent flood damage. This study develops a flash flood index through the average of the same scale relative severity factors quantifying characteristics of hydrographs generated from a rainfall-runoff model for the long-term observed rainfall data in a small ungauged study basin, and presents regression equations between rainfall characteristics and the flash flood index. The aim of this study is to develop flash flood index-duration-frequency relation curves by combining the rainfall intensity-duration-frequency relation and the flash flood index from probability rainfall data in order to evaluate vulnerability to extreme flash floods in design storms. This study is an initial effort to quantify the flash flood severity of design storms for both existing and planned flood control facilities to cope with residual flood risks due to extreme flash floods that have ocurred frequently in recent years. PMID:21845165
Tests of the Grobner Basis Solution for Lightning Ground Flash Fraction Retrieval
NASA Technical Reports Server (NTRS)
Koshak, William; Solakiewicz, Richard; Attele, Rohan
2011-01-01
Satellite lightning imagers such as the NASA Tropical Rainfall Measuring Mission Lightning Imaging Sensor (TRMM/LIS) and the future GOES-R Geostationary Lightning Mapper (GLM) are designed to detect total lightning (ground flashes + cloud flashes). However, there is a desire to discriminate ground flashes from cloud flashes from the vantage point of space since this would enhance the overall information content of the satellite lightning data and likely improve its operational and scientific applications (e.g., in severe weather warning, lightning nitrogen oxides studies, and global electric circuit analyses). A Bayesian inversion method was previously introduced for retrieving the fraction of ground flashes in a set of flashes observed from a satellite lightning imager. The method employed a constrained mixed exponential distribution model to describe the lightning optical measurements. To obtain the optimum model parameters (one of which is the ground flash fraction), a scalar function was minimized by a numerical method. In order to improve this optimization, a Grobner basis solution was introduced to obtain analytic representations of the model parameters that serve as a refined initialization scheme to the numerical optimization. In this study, we test the efficacy of the Grobner basis initialization using actual lightning imager measurements and ground flash truth derived from the national lightning network.
Assessment of vulnerability to extreme flash floods in design storms.
Kim, Eung Seok; Choi, Hyun Il
2011-07-01
There has been an increase in the occurrence of sudden local flooding of great volume and short duration caused by heavy or excessive rainfall intensity over a small area, which presents the greatest potential danger threat to the natural environment, human life, public health and property, etc. Such flash floods have rapid runoff and debris flow that rises quickly with little or no advance warning to prevent flood damage. This study develops a flash flood index through the average of the same scale relative severity factors quantifying characteristics of hydrographs generated from a rainfall-runoff model for the long-term observed rainfall data in a small ungauged study basin, and presents regression equations between rainfall characteristics and the flash flood index. The aim of this study is to develop flash flood index-duration-frequency relation curves by combining the rainfall intensity-duration-frequency relation and the flash flood index from probability rainfall data in order to evaluate vulnerability to extreme flash floods in design storms. This study is an initial effort to quantify the flash flood severity of design storms for both existing and planned flood control facilities to cope with residual flood risks due to extreme flash floods that have ocurred frequently in recent years.
Flash (Ultra-Rapid) Spark-Plasma Sintering of Silicon Carbide
Olevsky, Eugene A.; Rolfing, Stephen M.; Maximenko, Andrey L.
2016-01-01
A new ultra-rapid process of flash spark plasma sintering is developed. The idea of flash spark plasma sintering (or flash hot pressing - FHP) stems from the conducted theoretical analysis of the role of thermal runaway phenomena for material processing by flash sintering. The major purpose of the present study is to theoretically analyze the thermal runaway nature of flash sintering and to experimentally address the challenge of uncontrollable thermal conditions by the stabilization of the flash sintering process through the application of the external pressure. The effectiveness of the developed FHP technique is demonstrated by the few seconds–long consolidation of SiC powder in an industrial spark plasma sintering device. Specially designed sacrificial dies heat the pre-compacted SiC powder specimens to a critical temperature before applying any voltage to the powder volume and allowing the electrode-punches of the SPS device setup to contact the specimens and pass electric current through them under elevated temperatures. The experimental results demonstrate that flash sintering phenomena can be realized using conventional SPS devices. The usage of hybrid heating SPS devices is pointed out as the mainstream direction for the future studies and utilization of the new flash hot pressing (ultra-rapid spark plasma sintering) technique. PMID:27624641
Flash (Ultra-Rapid) Spark-Plasma Sintering of Silicon Carbide
Olevsky, Eugene A.; Rolfing, Stephen M.; Maximenko, Andrey L.
2016-09-14
A new ultra-rapid process of flash spark plasma sintering is developed. The idea of flash spark plasma sintering (or flash hot pressing - FHP) stems from the conducted theoretical analysis of the role of thermal runaway phenomena for material processing by flash sintering. The major purpose of the present study is to theoretically analyze the thermal runaway nature of flash sintering and to experimentally address the challenge of uncontrollable thermal conditions by the stabilization of the flash sintering process through the application of the external pressure. The effectiveness of the developed FHP technique is demonstrated by the few seconds–long consolidationmore » of SiC powder in an industrial spark plasma sintering device. Specially designed sacrificial dies heat the pre-compacted SiC powder specimens to a critical temperature before applying any voltage to the powder volume and allowing the electrode-punches of the SPS device setup to contact the specimens and pass electric current through them under elevated temperatures. The experimental results demonstrate that flash sintering phenomena can be realized using conventional SPS devices. The usage of hybrid heating SPS devices is pointed out as the mainstream direction for the future studies and utilization of the new flash hot pressing (ultra-rapid spark plasma sintering) technique.« less
Flash Floods Simulation using a Physical-Based Hydrological Model at Different Hydroclimatic Regions
NASA Astrophysics Data System (ADS)
Saber, Mohamed; Kamil Yilmaz, Koray
2016-04-01
Currently, flash floods are seriously increasing and affecting many regions over the world. Therefore, this study will focus on two case studies; Wadi Abu Subeira, Egypt as arid environment, and Karpuz basin, Turkey as Mediterranean environment. The main objective of this work is to simulate flash floods at both catchments considering the hydrometeorological differences between them which in turn effect their flash flood behaviors. An integrated methodology incorporating Hydrological River Basin Environmental Assessment Model (Hydro-BEAM) and remote sensing observations was devised. Global Satellite Mapping of Precipitation (GSMAP) were compared with the rain gauge network at the target basins to estimate the bias in an effort to further use it effectively in simulation of flash floods. Based on the preliminary results of flash floods simulation on both basins, we found that runoff behaviors of flash floods are different due to the impacts of climatology, hydrological and topographical conditions. Also, the simulated surface runoff hydrographs are reasonably coincide with the simulated ones. Consequently, some mitigation strategies relying on this study could be introduced to help in reducing the flash floods disasters at different climate regions. This comparison of different climatic basins would be a reasonable implication for the potential impact of climate change on the flash floods frequencies and occurrences.
NASA Astrophysics Data System (ADS)
Khajehei, S.; Moradkhani, H.
2017-12-01
Understanding socio-economic characteristics involving natural hazards potential, vulnerability, and resilience is necessary to address the damages to economy and loss of life from extreme natural hazards. The vulnerability to flash floods is dependent on both biophysical and socio-economic factors. Although the biophysical characteristics (e.g. climate, vegetation, and land use) are informative and useful for predicting spatial and temporal extent of flash floods, they have minimal bearing on predicting when and where flash floods are likely to influence people or damage valuable assets and resources. The socio-economic factors determine spatial and temporal scales of the regions affected by flash floods. In this study, we quantify the socio-economic vulnerability to flash floods across the Contiguous United States (CONUS). A socio-economic vulnerability index was developed, employing Bayesian principal components for each state in the CONUS. For this purpose, extensive sets of social and economic variables from US Census and the Bureau of Economic Analysis were used. We developed maps presenting the coincidence of socio-economic vulnerability and the flash floods records. This product can help inform flash flood prevention, mitigation and recovery planning, as well as reducing the flash flood hazards affecting vulnerable places and population.
The properties of optical lightning flashes and the clouds they illuminate
NASA Astrophysics Data System (ADS)
Peterson, Michael; Deierling, Wiebke; Liu, Chuntao; Mach, Douglas; Kalb, Christina
2017-01-01
Optical lightning sensors like the Optical Transient Detector and Lightning Imaging Sensor (LIS) measure total lightning across large swaths of the globe with high detection efficiency. With two upcoming missions that employ these sensors - LIS on the International Space Station and the Geostationary Lightning Mapper on the GOES-R satellite - there has been increased interest in what these measurements can reveal about lightning and thunderstorms in addition to total flash activity. Optical lightning imagers are capable of observing the characteristics of individual flashes that include their sizes, durations, and radiative energies. However, it is important to exercise caution when interpreting trends in optical flash measurements because they can be affected by the scene. This study uses coincident measurements from the Tropical Rainfall Measuring Mission (TRMM) satellite to examine the properties of LIS flashes and the surrounding cloud regions they illuminate. These combined measurements are used to assess to what extent optical flash characteristics can be used to make inferences about flash structure and energetics. Clouds illuminated by lightning over land and ocean regions that are otherwise similar based on TRMM measurements are identified. Even when LIS flashes occur in similar clouds and background radiances, oceanic flashes are still shown to be larger, brighter, longer lasting, more prone to horizontal propagation, and to contain more groups than their land-based counterparts. This suggests that the optical trends noted in literature are not entirely the result of radiative transfer effects but rather stem from physical differences in the flashes.
New stimulation pattern design to improve P300-based matrix speller performance at high flash rate
NASA Astrophysics Data System (ADS)
Polprasert, Chantri; Kukieattikool, Pratana; Demeechai, Tanee; Ritcey, James A.; Siwamogsatham, Siwaruk
2013-06-01
Objective. We propose a new stimulation pattern design for the P300-based matrix speller aimed at increasing the minimum target-to-target interval (TTI). Approach. Inspired by the simplicity and strong performance of the conventional row-column (RC) stimulation, the proposed stimulation is obtained by modifying the RC stimulation through alternating row and column flashes which are selected based on the proposed design rules. The second flash of the double-flash components is then delayed for a number of flashing instants to increase the minimum TTI. The trade-off inherited in this approach is the reduced randomness within the stimulation pattern. Main results. We test the proposed stimulation pattern and compare its performance in terms of selection accuracy, raw and practical bit rates with the conventional RC flashing paradigm over several flash rates. By increasing the minimum TTI within the stimulation sequence, the proposed stimulation has more event-related potentials that can be identified compared to that of the conventional RC stimulations, as the flash rate increases. This leads to significant performance improvement in terms of the letter selection accuracy, the raw and practical bit rates over the conventional RC stimulation. Significance. These studies demonstrate that significant performance improvement over the RC stimulation is obtained without additional testing or training samples to compensate for low P300 amplitude at high flash rate. We show that our proposed stimulation is more robust to reduced signal strength due to the increased flash rate than the RC stimulation.
Gallicchio, Lisa; Miller, Susan R.; Kiefer, Judith; Greene, Teresa; Zacur, Howard A.; Flaws, Jodi A.
2015-01-01
Objective The aim of this study was to examine the associations between demographic characteristics, health behaviors, hormone concentrations, and the experiencing of any, current, more severe, and more frequent midlife hot flashes. Methods Baseline data were analyzed from 732 women aged 45 to 54 years enrolled in the Midlife Women's Health Study. A clinic visit was conducted to collect blood samples for hormone assays and to measure ovarian volume using transvaginal ultrasound. A self-administered questionnaire ascertained information on demographic factors, health habits, and hot flashes history. Multivariable logistic regression was conducted to examine the associations between potential risk factors and the hot flashes outcomes. Results Approximately 45% of participants reported experiencing midlife hot flashes. In the covariate-adjusted models, older age, peri-menopausal status, current and former cigarette smoking, and depressive symptoms were significantly associated with increased odds of all of the hot flashes outcomes. In addition, history of oral contraceptive use was associated with increased odds of any hot flashes. In contrast, higher current alcohol intake was significantly associated with decreased odds of any, current, and more severe hot flashes. Higher estradiol and progesterone concentrations were significantly associated with decreased odds of all hot flashes outcomes. Conclusions Although the temporalities of such associations are not known due to the cross-sectional nature of the data, these observed relationships can help to identify women at risk for hot flashes. PMID:25783472
NASA Technical Reports Server (NTRS)
Breslawski, Christine
1990-01-01
An analysis of video tapes of nocturnal lightning events, taken aboard space shuttle flights STS-8, STS-9, STS-41D, and STS-51J, shows flashes with dimensions ranging from approximately 1 km by 1 km to 440 km by 110 km. Of particular interest are the flashes whose dimensions exceeded 100 km, as flashes of this size are seldom reported. In general, larger flashes were found to have longer durations, take longer to reach their maximum extent, and reach their maximum extent at a smaller percent of their total duration than smaller flashes. Sixty four percent of the flashes occurred with one to five other events appearing in the same video frame. These simultaneous events were an average of 60 km apart from each other. If a breakdown process is propagating between the simultaneous flashes, it would be travelling at a rate of 10(exp 5)m/sec. Plots of the area of an event over its duration show peaks in the area curve which may be indicative if lightning strokes. There was an average of 3.6 peaks per flash. In general, the longer the flash duration, the more peaks there were in the area curve. The area curves of the lightning events fall into one of five shape categories. It is suggested that the shape of the area curve may indicate whether an event is an intracloud or cloud to ground lightning flash. Some of the lightning events had a persistent bright spot. These events had an average duration which was greater than that of events without the bright spot. On average, the bright spot events had a maximum area which was larger than that of the flashes without the bright spot.
Kappa Agonists as a Novel Therapy for Menopausal Hot Flashes
Oakley, Amy E.; Steiner, Robert A.; Chavkin, Charles; Clifton, Donald K.; Ferrara, Laura K.; Reed, Susan D.
2015-01-01
Objective Postmenopausal hot flash etiology is poorly understood, making it difficult to develop and target ideal therapies. A network of hypothalamic estrogen-sensitive neurons producing Kisspeptin, Neurokinin B, and Dynorphin (KNDy neurons), located adjacent to the thermoregulatory center, regulate pulsatile secretion of GnRH and LH. Dynorphin may inhibit this system by binding kappa opioid receptors within the vicinity of KNDy neurons. We hypothesize that hot flashes are reduced by KNDy neuron manipulation. Methods A double-blind, cross-over, placebo-controlled pilot study evaluated the effect of a kappa agonist (KA).Hot flash frequency was the primary outcome. Twelve healthy postmenopausal women with moderate-severe hot flashes, ages 48-60 years, were randomized. Eight women with sufficient baseline hot flashes for statistical analysis completed all 3 interventions: placebo, standard Pentazocine/Naloxone (50/0.5 mg) or low-dose Pentazocine/Naloxone (25/0.25 mg). In an inpatient research setting, each participant received the 3 interventions, in randomized order, on 3 separate days. On each day, an intravenous catheter was inserted for luteinizing hormone (LH) blood sampling, and skin conductance and Holter monitors were placed. Subjective hot flash frequency and severity were recorded. Results Mean hot flash frequency 2-7 hours following therapy initiation was lower than that for placebo (KA standard-dose: 4.75 ± 0.67; KA low-dose: 4.50 ± 0.57; and placebo: 5.94 ± 0.78 hot flashes/5 hours; p =0.025). Hot flash intensity did not vary between interventions. LH pulsatility mirrored objective hot flashes in some, but not all women. Conclusions This pilot suggests that kappa agonists may affect menopausal vasomotor symptoms. PMID:25988798
Jeong, Young Ju; Park, Young Sun; Kwon, Hyo Jung; Shin, Im Hee; Bong, Jin Gu
2013-01-01
Abstract Objectives Antiestrogen therapy can cause vasomotor symptoms similar to those occurring during menopause, including hot flashes. Recent studies suggest that acupuncture is effective in reducing vasomotor symptoms in patients with breast cancer receiving tamoxifen. The purpose of this study was to assess the feasibility and safety of acupuncture for treatment of hot flashes in Korean patients with breast cancer receiving antiestrogen therapy. Design This was a prospective single-arm observational study using before and after measurements. Settings/location The study was located at the East–West Medical Center at Daegu Catholic University Medical Center, Daegu, Korea. Subjects The subjects were 10 patients with breast cancer who were undergoing antiestrogen therapy with tamoxifen or anastrozole and who were suffering from hot flashes. Interventions Acupuncture was administered 3 times a week for 4 consecutive weeks, for 20±5 minutes at each session. Outcome measures The outcome measure was severity of hot flashes assessed by visual analogue scale (VAS) and total hot flash score. Results During treatment, severity of hot flashes was reduced by 70%–95% in all patients. Acupuncture significantly alleviated severity of hot flashes assessed by a visual analogue scale (F=30.261; p<0.001) as well as the total hot flash score (F=21.698; p=0.006). Four (4) weeks after the final treatment, symptoms were not aggravated. Conclusions Acupuncture appeared to provide effective relief from hot flashes among Korean women receiving antiestrogen therapy after surgery for breast cancer, and the effects lasted for at least 1 month after termination of treatment. A randomized controlled prospective study with a larger sample size is required to clarify the role of acupuncture in the management of hot flashes in Korean patients with breast cancer. PMID:23383974
Flood hazard assessment in areas prone to flash flooding
NASA Astrophysics Data System (ADS)
Kvočka, Davor; Falconer, Roger A.; Bray, Michaela
2016-04-01
Contemporary climate projections suggest that there will be an increase in the occurrence of high-intensity rainfall events in the future. These precipitation extremes are usually the main cause for the emergence of extreme flooding, such as flash flooding. Flash floods are among the most unpredictable, violent and fatal natural hazards in the world. Furthermore, it is expected that flash flooding will occur even more frequently in the future due to more frequent development of extreme weather events, which will greatly increase the danger to people caused by flash flooding. This being the case, there will be a need for high resolution flood hazard maps in areas susceptible to flash flooding. This study investigates what type of flood hazard assessment methods should be used for assessing the flood hazard to people caused by flash flooding. Two different types of flood hazard assessment methods were tested: (i) a widely used method based on an empirical analysis, and (ii) a new, physically based and experimentally calibrated method. Two flash flood events were considered herein, namely: the 2004 Boscastle flash flood and the 2007 Železniki flash flood. The results obtained in this study suggest that in the areas susceptible to extreme flooding, the flood hazard assessment should be conducted using methods based on a mechanics-based analysis. In comparison to standard flood hazard assessment methods, these physically based methods: (i) take into account all of the physical forces, which act on a human body in floodwater, (ii) successfully adapt to abrupt changes in the flow regime, which often occur for flash flood events, and (iii) rapidly assess a flood hazard index in a relatively short period of time.
TRMM-Based Lightning Climatology
NASA Technical Reports Server (NTRS)
Cecil, Daniel J.; Buechler, Dennis E.; Blakeslee, Richard J.
2011-01-01
Gridded climatologies of total lightning flash rates seen by the spaceborne Optical Transient Detector (OTD) and Lightning Imaging Sensor (LIS) have been updated. OTD collected data from May 1995 to March 2000. LIS data (equatorward of about 38 deg) has been added for 1998-2010. Flash counts from each instrument are scaled by the best available estimates of detection efficiency. The long LIS record makes the merged climatology most robust in the tropics and subtropics, while the high latitude data is entirely from OTD. The mean global flash rate from the merged climatology is 46 flashes per second. The peak annual flash rate at 0.5 deg scale is 160 fl/square km/yr in eastern Congo. The peak monthly average flash rate at 2.5 scale is 18 fl/square km/mo, from early April to early May in the Brahmaputra Valley of far eastern India. Lightning decreases in this region during the monsoon season, but increases further north and west. A monthly average peak from early August to early September in northern Pakistan also exceeds any monthly averages from Africa, despite central Africa having the greatest yearly average. Most continental regions away from the equator have an annual cycle with lightning flash rates peaking in late spring or summer. The main exceptions are India and southeast Asia, with springtime peaks in April and May. For landmasses near the equator, flash rates peak near the equinoxes. For many oceanic regions, the peak flash rates occur in autumn. This is particularly noticeable for the Mediterranean and North Atlantic. Landmasses have a strong diurnal cycle of lightning, with flash rates generally peaking between 3-5 pm local solar time. The central United States flash rates peak later, in late evening or early night. Flash rates peak after midnight in northern Argentina. These regions are known for large, intense, long-lived mesoscale convective systems.
NASA Astrophysics Data System (ADS)
Ma, M.; Wang, H.; Chen, Y.; Tang, G.; Hong, Z.; Zhang, K.; Hong, Y.
2017-12-01
Flash floods, one of the deadliest natural hazards worldwide due to their multidisciplinary nature, rank highly in terms of heavy damage and casualties. Such as in the United States, flash flood is the No.1 cause of death and the No. 2 most deadly weather-related hazard among all storm-related hazards, with approximately 100 lives lost each year. According to China Floods and Droughts Disasters Bullet in 2015 (http://www.mwr.gov.cn/zwzc/hygb/zgshzhgb), about 935 deaths per year on average were caused by flash floods from 2000 to 2015, accounting for 73 % of the fatalities due to floods. Therefore, significant efforts have been made toward understanding flash flood processes as well as modeling and forecasting them, it still remains challenging because of their short response time and limited monitoring capacity. This study advances the use of high-resolution Global Precipitation Measurement forecasts (GPMs), disaster data obtained from the government officials in 2011 and 2016, and the improved Distributed Flash Flood Guidance (DFFG) method combining the Distributed Hydrologic Model and Soil Conservation Service Curve Numbers. The objectives of this paper are (1) to examines changes in flash flood occurrence, (2) to estimate the effect of the rainfall spatial variability ,(2) to improve the lead time in flash floods warning and get the rainfall threshold, (3) to assess the DFFG method applicability in Dongchuan catchments, and (4) to yield the probabilistic information about the forecast hydrologic response that accounts for the locational uncertainties of the GPMs. Results indicate: (1) flash flood occurrence increased in the study region, (2) the occurrence of predicted flash floods show high sensitivity to total infiltration and soil water content, (3) the DFFG method is generally capable of making accurate predictions of flash flood events in terms of their locations and time of occurrence, and (4) the accumulative rainfall over a certain time span is an appropriate threshold for flash flood warnings. Finally, the article highlights the importance of accurately simulating the hydrological processes and high-resolution satellite rainfall data on the accurate forecasting of rainfall triggered flash flood events.
NASA Technical Reports Server (NTRS)
Pickering, K. E.; Barth, M. C.; Koshak, W.; Bucsela, E. J.; Allen, D. J.; Weinheimer, A.; Ryerson, T.; Huntrieser, H.; Bruning, E.; MacGorman, D.;
2012-01-01
Some of the major goals of the DC3 experiment are to determine the contribution of lightning to NO(x) in the anvils of observed thunderstorms, examine the relationship of lightning NO(x) production to flash rates and to lightning channel lengths, and estimate the relative production per flash for cloud-to-ground flashes and intracloud flashes. In addition, the effects of lightning NO(x) production on photochemistry downwind of thunderstorms is also being examined. The talk will survey the observation types that were conducted during DC3 relevant to these goals and provide an overview of the analysis and modeling techniques which are being used to achieve them. NO(x) was observed on three research aircraft during DC3 (the NCAR G-V, the NASA DC-8, and the DLR Falcon) in flights through storm anvils in three study regions (NE Colorado, Central Oklahoma to West Texas, and northern Alabama) where lightning mapping arrays (LMAs) and radar coverage were available. Initial comparisons of the aircraft NOx observations in storm anvils relative to flash rates have been conducted, which will be followed with calculations of the flux of NO(x) through the anvils, which when combined with observed flash rates can be used to estimate storm-average lightning NOx production per flash. The WRF-Chem model will be run for cloud-resolved simulations of selected observed storms during DC3. Detailed lightning information from the LMAs (flash rates and flash lengths as a function of time and vertical distributions of flash channel segments) will be input to the model along with assumptions concerning NO(x) production per CG flash and per IC flash. These assumptions will be tested through comparisons with the aircraft NOx data from anvil traverses. A specially designed retrieval method for lightning NO2 column amounts from the OMI instrument on NASA fs Aura satellite has been utilized to estimate NO2 over the region affected by selected DC3 storms. Combined with NO(x) to NO2 ratios from the aircraft data and WRF-Chem model and observed flash rates, average NO(x) production per flash can be estimated. Ozone production downwind of observed storms can be estimated from the WRF-Chem simulations and the specific downwind flights.
NASA Astrophysics Data System (ADS)
Kuhlman, K. M.; Coy, J.; Seimon, A.
2015-12-01
Cloud-to-ground (CG) lightning flashes recorded by both the National Lightning Detection Network (NLDN) and Earth Networks Total Lightning Network (ENTLN) are compared with three-dimensional lightning mapping observations from the Oklahoma Lightning Mapping Array (OKLMA) and storm chaser video recorded of the 31 May 2013 El Reno tornadic supercell. The El Reno Survey Project (El-Reno-Survey.net) was created to crowd-source the abundance of storm chaser video from this event and provide open-access to the scientific community of the data. An initial comparison of CG lightning flashes captured on these videos with CG data from NLDN revealed a disagreement on the total number of flashes, with NLDN recording many negative CG flashes at lower peak amplitude not apparent in any of the videos. For this study, the area of the comparison was expanded to include the entire storm and data from both the ENTLN and LMA were added to compare the observations from each network in terms of timestamp, location detection, peak current, and polarity of each flash in the period 2230-2330 UTC. An initial comparison of 557 matched NLDN and ENLTN CG flashes, indicated predominately negative polairy CG flashes (58% NLDN/77% ENI) throughout the storm during this period. However, after a 15 kA peak current filter was applied, the NLDN indicated primarily positive polarity (84% +CG) while ENTLN still indicated primarily negative polarity (77% -CG) for the 264 remaining matched flashes. Before the filter was applied, the average distance between the two networks for the same flash was more than 2 km, but improved to approximately 1 km after the 15 kA filter was applied, likely removing some misidentified cloud flashes of uncertain location. This misclassification of IC flashes as CG at low peak current amplitudes for both networks is further evident when compared to video and the OKLMA data. Additionally, the charge analysis of OKLMA flashes revealed the NLDN-determined positive-polarity as correct every time the NLDN and ENTLN disagreed. For the 2013 El Reno supercell storm, there appears to be a major flaw in the ENTLN's ability to determine the polarity of CG flashes despite having roughly similar peak current magnitudes and location for most CG flash occurrences as the NLDN.
Characteristics of the most intense lightning storm ever recorded at the CN Tower
NASA Astrophysics Data System (ADS)
Hussein, A. M.; Kazazi, S.; Anwar, M.; Yusouf, M.; Liatos, P.
2017-02-01
Lightning strikes to the CN Tower have been optically observed since 1978. In 1990, five independent systems started to operate to simultaneously record parameters of lightning strikes to the tower, including the time derivative of the current, the associated electric and magnetic fields, and the channel optical characteristics. On August 24, 2011, during an unusually severe lightning storm, video records showed that the CN Tower was struck with 52 lightning flashes within 84 min and 6.9 s. Thus, this storm produced, on average, a flash to the tower every 99 s. However, the CN Tower lightning current derivative measurement system only recorded 32 flashes, which were perfectly time-matched with 32 of the 52 video-recorded flashes. It is found that the current derivative measurement system recorded every video-recorded flash that contained at least one return stroke. Based on the analysis of video records, it is noted that each of the storm's 52 flashes contains an initial-stage current, proving that all flashes were upward initiated. This unique CN Tower storm - the most intense ever recorded at the tower - is here thoroughly analyzed, based on video and current records. The inter-flash time within the storm is found to vary between 10.6 s and 274 s, with an overall average of 98 s. It is also found that the inter-flash time between successive non-return-stroke flashes is on average 64% longer than that for successive flashes containing return strokes. Statistical analysis of video and current data clearly reveals that the time duration of flashes containing initial-stage currents and return strokes is on average 27% longer than that of flashes that only have initial-stage currents. Furthermore, it is important to note that the time duration of the initial-stage current in flashes containing no return strokes is on average 76% longer than that in flashes containing return strokes. Therefore, it is possible to conclude that if the time duration of the initial-stage current in a flash is long enough, resulting in large charge transfer, then there is less probability of having return strokes following it. The 32 current-recorded flashes contain a total of 156 return strokes, with an average multiplicity of 4.875. It is worth mentioning that during one decade, 1992-2001, the CN Tower current derivative measurement system only recorded 478 return strokes, demonstrating that the number of return strokes recorded at the tower within about 84 min is close to one third of those recorded at the tower during one decade. This finding clearly shows the great value and rarity of the presented extensive lightning current derivative data. Only one of the 32 current-recorded flashes is proved to be positive with a single return stroke. Based on current records, out of a total of 124 inter-stroke time intervals, 94% are found to be within 200 ms, with an overall inter-stroke time average of 68.1 ms. The maximum inter-stroke time recorded during this storm is 726.3 ms, the longest ever recorded at the CN Tower.
An Alternative Explanation for "Step-Like" Early VLF Event
NASA Astrophysics Data System (ADS)
Moore, R. C.
2016-12-01
A newly-deployed array of VLF receivers along the East Coast of the United States is ideally suited for detecting VLF scattering from lightning-induced disturbances to the lower ionosphere. The array was deployed in May 2016, and one VLF receiver was deployed only 20 km from the NAA transmitter (24.0 kHz) in Cutler, Maine. The phase of the NAA signal at this closest site varies significantly with time, due simply to the impedance match of the transmitter varying with time. Additionally, both the amplitude and phase exhibit periods of rapid shifts that could possibly explain at least some "step-like" VLF scattering events. Here, we distinguish between "step-like" VLF scattering events and other events in that "step-like" events are typically not closely associated with a detected causative lightning flash and also tend to exhibit little or no recovery to ambient conditions after the event onset. We present an analysis of VLF observations from the East Coast array that demonstrates interesting examples of step-like VLF events far from the transmitter that are associated with step-like events very close to the transmitter. We conclude that step-like VLF events should be treated with caution, unless definitively associated with a causative lightning flash and/or detected using observations of multiple transmitter signals.
Staley, Dennis M.; Gartner, Joseph E.; Kean, Jason W.
2015-01-01
We present an objectively defined rainfall intensity-duration (I-D) threshold for the initiation of flash floods and debris flows for basins recently burned in the 2012 Waldo Canyon fire near Colorado Springs, Colorado, USA. Our results are based on 453 rainfall records which include 8 instances of hazardous flooding and debris flow from 10 July 2012 to 14 August 2013. We objectively defined the thresholds by maximizing the number of correct predictions of debris flow or flood occurrence while minimizing the rate of both Type I (false positive) and Type II (false negative) errors. The equation I = 11.6D−0.7 represents the I-D threshold (I, in mm/h) for durations (D, in hours) ranging from 0.083 h (5 min) to 1 h for basins burned by the 2012 Waldo Canyon fire. As periods of high-intensity rainfall over short durations (less than 1 h) produced all of the debris flow and flood events, real-time monitoring of rainfall conditions will result in very short lead times for early-warning. Our results highlight the need for improved forecasting of the rainfall rates during short-duration, high-intensity convective rainfall events.
Effect of Strontium Nitrate on Extremely Slow Strobe Compositions
2017-01-01
SUBJECT TERMS Strobe Hang fire Flash Orion’s Flashing Guns 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF... Guns Formulations .......................................................................2 2. Modifications of Orion’s Flashing Guns , Resulting...Flashing Guns ” (3). These compositions used barium nitrate as the oxidizer and magnalium as the fuel. Both also contained a substantial amount of sulfur
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-13
... INTERNATIONAL TRADE COMMISSION [Inv. No. 337-TA-735] In the Matter of Certain Flash Memory Chips... the sale within the United States after importation of certain flash memory chips and products... importation of certain flash memory chips and products containing the same that infringe one or more of claims...
Compact and reliable triggering method for near muzzle flash radiography
NASA Astrophysics Data System (ADS)
Lee, Eun S.; Hwang, Eul H.; Yim, Dong W.; Song, So Y.
1993-01-01
Precise timing for x-ray bursts is crucial in acquiring useful information from flash radiographic experiments. Triggering the flash x-ray system near the muzzle is a difficult task because of the intrinsic nature of the muzzle blast. In this work a compact and reliable triggering method for near muzzle flash radiography is introduced; a piezoelectric pin probe attached at the end of the barrel. These types of probes have not been activated by the precursor shock wave, but they have been activated by the main blast wave only. Reliability in triggering the flash x-ray system has been confirmed throughout a series of flash radiographic experiments near the muzzle for gun barrels with calibers up to 105 mm.
Principles of Lightning Physics
NASA Astrophysics Data System (ADS)
Mazur, Vladislav
2016-12-01
Principles of Lightning Physics presents and discusses the most up-to-date physical concepts that govern many lightning events in nature, including lightning interactions with man-made structures, at a level suitable for researchers, advanced students and well-educated lightning enthusiasts. The author's approach to understanding lightning-to seek out, and show what is common to all lightning flashes-is illustrated by an analysis of each type of lightning and the multitude of lightning-related features. The book examines the work that has gone into the development of new physical concepts, and provides critical evaluations of the existing understanding of the physics of lightning and the lexicon of terms and definitions presently used in lightning research.
Weber, Shannon
2015-01-01
I analyze three case studies of marriage equality activism and marriage equality-based groups after the passage of Proposition 8 in California. Evaluating the JoinTheImpact protests of 2008, the LGBTQ rights group GetEQUAL, and the group One Struggle One Fight, I argue that these groups revise queer theoretical arguments about marriage equality activism as by definition assimilationist, homonormative, and single-issue. In contrast to such claims, the cases studied here provide a snapshot of heterogeneous, intersectional, and coalition-based social justice work in which creative methods of protest, including direct action and flash mobs, are deployed in militant ways for marriage rights and beyond.
Experimental comparison of various techniques for spot size measurement of high-energy X-ray
NASA Astrophysics Data System (ADS)
Wang, Yi; Li, Qin; Chen, Nan; Cheng, Jin-Ming; Li, Cheng-Gang; Li, Hong; Long, Quan-Hong; Shi, Jin-Shui; Deng, Jian-Jun
2016-08-01
In flash-radiography experiments, the quality of the acquired image strongly depends on the focal size of the X-ray source spot. A variety of techniques based on imaging of the pinhole, the slit and the rollbar are adopted to measure the focal spot size of the Dragon-I linear induction accelerator. The image of the pinhole provides a two-dimensional distribution of the X-ray spot, while those of the slit and the rollbar give a line-spread distribution and an edge-spread distribution, respectively. The spot size characterized by the full-width at half-maximum and that characterized by the LANL definition are calculated for comparison.
Flash ionization signature in coherent cyclotron emission from brown dwarfs
NASA Astrophysics Data System (ADS)
Vorgul, I.; Helling, Ch.
2016-05-01
Brown dwarfs (BDs) form mineral clouds in their atmospheres, where charged particles can produce large-scale discharges in the form of lightning resulting in substantial sudden increase of local ionization. BDs are observed to emit cyclotron radio emission. We show that signatures of strong transient atmospheric ionization events (flash ionization) can be imprinted on a pre-existing radiation. Detection of such flash ionization events will open investigations into the ionization state and atmospheric dynamics. Such events can also result from explosion shock waves, material outbursts or (volcanic) eruptions. We present an analytical model that describes the modulation of a pre-existing electromagnetic radiation by a time-dependent (flash) conductivity that is characteristic for flash ionization events like lightning. Our conductivity model reproduces the conductivity function derived from observations of terrestrial gamma-ray flashes, and is applicable to astrophysical objects with strong temporal variations in the local ionization, as in planetary atmospheres and protoplanetary discs. We show that the field responds with a characteristic flash-shaped pulse to a conductivity flash of intermediate intensity. More powerful ionization events result in smaller variations of the initial radiation, or in its damping. We show that the characteristic damping of the response field for high-power initial radiation carries information about the ionization flash magnitude and duration. The duration of the pulse amplification or the damping is consistently shorter for larger conductivity variations and can be used to evaluate the intensity of the flash ionization. Our work suggests that cyclotron emission could be probe signals for electrification processes inside BD atmosphere.
Rabbit electroretinograms evoked by 632.8nm laser flash stimuli
NASA Astrophysics Data System (ADS)
Yang, Zai-Fu; Chen, Hong-Xia; Wang, Jia-Rui; Guan, Bo-Lin; Yu, Guang-Yuan; Zhang, Xiao-Na; Zhang, Wen-Yuan; Yang, Jing-Geng
2012-12-01
The flash electroretinography is a standard electrophysiological method and widely employed in basic research and ophthalmology clinics, of which the stimulus is usually white flash from dome stimulator. However, little is known about the electroretinograms (ERGs) evoked by monochromatic laser flash stimuli. The goal of this research effort is to quantify the ERGs of dark-adapted New Zealand rabbits elicited by He-Ne laser flash with wavelength 632.8 nm. The flash field was a Maxwellian viewing disc with angular subtense of 8.5°, 13.3° or 20.2°. The stimulus duration was 12 ms, 22 ms, 70 ms or 220 ms. The laser flash power incident on the cornea varied from 2.2 nW through 22 mW. Under the condition of 20 ms stimulus duration and 20.2° flash field, the ERG of New Zealand rabbit was compared with that of Chinchilla gray rabbit. Results showed that for the ERG b-wave, with the increase of laser energy, the amplitude first increased, then met a trough and finally increased again, the implicit time decreased first and then met a platform. While for the ERG a-wave, the amplitude increased and the implicit time decreased monotonically. Longer stimulus duration led to lower b-wave amplitude under equal flash power level. The flash field size showed limited effect on the ERG, especially on the low energy end. As compared with the pigmented rabbit, the albino rabbit was more sensitive and the threshold energy for b-wave excitation was about 10 times lower.
Efficacy of a biobehavioral intervention for hot flashes: a randomized controlled pilot study.
Barton, Debra L; Schroeder, Kelliann C Fee; Banerjee, Tanima; Wolf, Sherry; Keith, Timothy Z; Elkins, Gary
2017-07-01
The need for effective nonhormonal treatments for hot flash management without unwanted side effects continues. The primary aim of this pilot study was to evaluate the effect of combining a nonhormonal pharmacologic agent with a behavioral treatment for hot flash reduction. Seventy-one postmenopausal women were randomized to one of four groups: venlafaxine 75 mg + hypnosis (VH) versus venlafaxine 75 mg + sham hypnosis (VSH) versus a placebo pill + hypnosis (PH) versus placebo pill + sham hypnosis (PSH). Women recorded hot flash severity and frequency in a daily diary, in real time. The intrapatient difference in hot flash score (frequency × severity) at 8 weeks was analyzed using a General Estimating Equation model, using VSH as the referent arm, controlling for baseline hot flashes. The active arms including PH or VH were not statistically significantly different than VSH (P = 0.34, P = 0.05, respectively). Women in each active arm reported hot flash reductions of about 50%, with the PSH group reporting a 25% reduction. Women receiving the PSH reported statistically significantly smaller reductions in hot flash score than women in the referent VSH arm (P = 0.001). There were no significant negative side effects during the course of the study. Hypnosis alone reduced hot flashes equal to venlafaxine alone, but the combination of hypnosis and venlafaxine did not reduce hot flashes more than either treatment alone. More research is needed to clarify whether combining hypnosis with a different antidepressant would provide synergistic benefits.
Weak positive cloud-to-ground flashes in Northeastern Colorado
NASA Technical Reports Server (NTRS)
Lopez, Raul E.; Maier, Michael W.; Garcia-Miguel, Juan A.; Holle, Ronald L.
1991-01-01
The frequency distributions of the peak magnetic field associated with the first detected return stroke of positive and negative cloud-to-ground (CG) flashes were studied using lightning data from northeastern Colorado. These data were obtained during 1985 with a medium-to-high gain network of three direction finders (DF's). The median signal strength of positive flashes was almost two times that of the negatives for flashes within 300 km of the DF's, which have an inherent detection-threshold bias that tends to discriminate against weak signals. This bias increases with range, and affects the detection of positive and negative flashes in different ways, because of the differing character of their distributions. Positive flashes appear to have a large percentage of signals clustered around very weak values that are lost to the medium-to-high gain Colorado Detection System very quickly with increasing range. The resulting median for positive signals could thus appear to be much larger than the median for negative signals, which are more clustered around intermediate values. When only flashes very close to the DF's are considered, however, the two distributions have almost identical medians. The large percentage of weak positive signals detected close to the DF's has not been explored previously. They have been suggested to come from intracloud discharges and thus are improperly classified as CG flashes. Evidence in hand, points to their being real positive, albeit weak CG flashes. Whether or not they are real positive ground flashes, it is important to be aware of their presence in data from magnetic DF networks.
Gong, Guohua; Wang, Xianhua; Wei-LaPierre, Lan; Cheng, Heping; Dirksen, Robert
2016-01-01
Abstract Significance: Recent breakthroughs in mitochondrial research have advanced, reshaped, and revolutionized our view of the role of mitochondria in health and disease. These discoveries include the development of novel tools to probe mitochondrial biology, the molecular identification of mitochondrial functional proteins, and the emergence of new concepts and mechanisms in mitochondrial function regulation. The discovery of “mitochondrial flash” activity has provided unique insights not only into real-time visualization of individual mitochondrial redox and pH dynamics in live cells but has also advanced understanding of the excitability, autonomy, and integration of mitochondrial function in vivo. Recent Advances: The mitochondrial flash is a transient and stochastic event confined within an individual mitochondrion and is observed in a wide range of organisms from plants to Caenorhabditis elegans to mammals. As flash events involve multiple transient concurrent changes within the mitochondrion (e.g., superoxide, pH, and membrane potential), a number of different mitochondrial targeted fluorescent indicators can detect flash activity. Accumulating evidence indicates that flash events reflect integrated snapshots of an intermittent mitochondrial process arising from mitochondrial respiration chain activity associated with the transient opening of the mitochondrial permeability transition pore. Critical Issues: We review the history of flash discovery, summarize current understanding of flash biology, highlight controversies regarding the relative roles of superoxide and pH signals during a flash event, and bring forth the integration of both signals in flash genesis. Future Directions: Investigations using flash as a biomarker and establishing its role in cell signaling pathway will move the field forward. Antioxid. Redox Signal. 25, 534–549. PMID:27245241
History of hot flashes and aortic calcification among postmenopausal women.
Thurston, Rebecca C; Kuller, Lewis H; Edmundowicz, Daniel; Matthews, Karen A
2010-03-01
Menopausal hot flashes are considered largely a quality-of-life issue. However, emerging research also links hot flashes to cardiovascular risk. In some investigations, this risk is particularly apparent among women using hormone therapy. The aim of this study was to determine whether a longer history of reported hot flashes over the study period was associated with greater aortic and coronary artery calcification. Interactions with hormone therapy use were examined in an exploratory fashion. Participants included 302 women participating in the Healthy Women Study, a longitudinal study of cardiovascular risk during perimenopause and postmenopause, which was initiated in 1983. Hot flashes (any/none) were assessed when women were 1, 2, 5, and 8 years postmenopausal. Electron beam tomography measures of coronary artery calcification and aortic calcification were completed in 1997-2004. Associations between the number of visits with report of hot flashes, divided by the number of visits attended, and aortic or coronary artery calcification (transformed) were examined in linear regression models. Interactions by hormone therapy use were evaluated. Among women using hormone therapy, a longer history of reported hot flashes was associated with increased aortic calcification, controlling for traditional cardiovascular risk factors (b = 2.87, SE = 1.21, P < 0.05). There were no significant associations between history of hot flashes and coronary artery calcification. Among postmenopausal women using hormone therapy, a longer history of reported hot flashes measured prospectively was associated with increased aortic calcification, controlling for traditional cardiovascular risk factors. Hot flashes may signal adverse cardiovascular changes among certain postmenopausal women.
Remote collection and analysis of witness reports on flash floods
NASA Astrophysics Data System (ADS)
Gourley, Jonathan; Erlingis, Jessica; Smith, Travis; Ortega, Kiel; Hong, Yang
2010-05-01
Typically, flash floods are studied ex post facto in response to a major impact event. A complement to field investigations is developing a detailed database of flash flood events, including minor events and null reports (i.e., where heavy rain occurred but there was no flash flooding), based on public survey questions conducted in near-real time. The Severe Hazards Analysis and Verification Experiment (SHAVE) has been in operation at the National Severe Storms Laboratory (NSSL) in Norman, OK, USA during the summers since 2006. The experiment employs undergraduate students to analyse real-time products from weather radars, target specific regions within the conterminous US, and poll public residences and businesses regarding the occurrence and severity of hail, wind, tornadoes, and now flash floods. In addition to providing a rich learning experience for students, SHAVE has been successful in creating high-resolution datasets of severe hazards used for algorithm and model verification. This talk describes the criteria used to initiate the flash flood survey, the specific questions asked and information entered to the database, and then provides an analysis of results for flash flood data collected during the summer of 2008. It is envisioned that specific details provided by the SHAVE flash flood observation database will complement databases collected by operational agencies and thus lead to better tools to predict the likelihood of flash floods and ultimately reduce their impacts on society.
Phototoxic effects of commercial photographic flash lamp on rat eyes.
Inoue, Makoto; Shinoda, Kei; Ohde, Hisao; Tezuka, Keiji; Hida, Tetsuo
2006-11-01
To determine whether exposure of the cornea and retina of rats to flashes from a commercial photographic flash lamp is phototoxic. Sprague-Dawley rats were exposed to 10, 100, or 1,000 flashes of the OPTICAM 16M photographic flash lamp (Fujikoeki, Japan) placed 0.1, 1, or 3 m from the eyes. Corneal damage was assessed by a fluorescein staining score, and the retinal damage by eletroretinography (ERG) and histology before and 24 h after exposure. Exposure of the eyes to 1,000 flashes at 0.1 m increased the fluorescein staining score significantly (P = 0.009, the Mann-Whitney test). Scanning electron microscopy (SEM) of the cornea showed a detachment of the epithelial cells from the surface after this exposure. The amplitude of the a-wave was decreased significantly by 23.0% (P = 0.026) of the amplitude before the exposure, and the b-wave by 19.7% (P = 0.0478) following 1,000 flashes at 0.1 m but not by the other exposures. TUNEL-positive cells were present in the outer nuclear layer only after the extreme exposure, but no significant decrease in retinal thickness was seen under any condition. The fluorescein staining score and ERGs recovered to control levels within 1 week. Light exposure to a photographic flash lamp does not induce damage to the cornea and retina except when they are exposed to 1,000 flashes at 0.1 m.
Long-term Stability of the Post-Flash LED Lamp
NASA Astrophysics Data System (ADS)
Martlin, Catherine; Baggett, Sylvia
2017-02-01
We report the results of a study of the long-term stability of the LED lamp used in post-flashing WFC3/UVIS images. We analyze 644 sub-array exposures taken over the course of just over 3 years and find no significant long-term trends in the LED lamp brightness. The average percentage change per year over all FLASH level and shutter combinations is found to be 0.15% per year with an uncertainty of ± 0.24% per year. The maximum measured percentage change per year was 0.39% for the highest FLASH level of 20 e- on shutter A which would indicate a change of less than 1 e-/pixel over the roughly 3 years since post-flashing began. There are, however, occasional short-term deviations in the LED output. The average minimum and maximum outliers over all FLASH level and shutter combination subsets are 4.1% below and 3.5% above, respectively, the mean of that subset. The maximum outlier over all the sets is 5.8% above the normalized mean value, for FLASH level 3/shutter A. The minimum outlier over all sets is also for FLASH level 3/shutter A and is 8.9% below the normalized mean value. Investigation of these outliers has revealed no systematic cause for the excursions and we recommend that users continue using the post-flash as they would have previously.
Evaluation of Flash Bainite in 4130 Steel
2011-07-01
Technical Report ARWSB-TR-11011 Evaluation of Flash Bainite in 4130 Steel G. Vigilante M. Hespos S. Bartolucci...4. TITLE AND SUBTITLE Evaluation of Flash Bainite in 4130 Steel 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT...need to be addressed, the Flash Bainite processing of 4130 steel demonstrates promise for applications needing a combination of high strength with
ERIC Educational Resources Information Center
Bigger, Stephen W.
2016-01-01
FlashPhotol is an educational software package that introduces students to the kinetics of transient species and fast reactions. This is achieved by means of a computer-simulated flash photolysis apparatus that comprises all major functional elements and that students can use to perform various experiments. The experimental interface presents a…
The Association between Body Mass Index and Hot Flash in Midlife Women: A Meta-analysis.
Shobeiri, Fatemeh; Jenabi, Ensiyeh; Poorolajal, Jalal; Hazavehei, Seyyed Mohammad Mahdi
2016-04-01
The association between body mass index (BMI) and hot flash risk has not been specifically clarifies yet. This meta-analysis was, therefore, conducted to estimate the association between overweight and obesity and hot flash risk. We searched PubMed, Web of Science, and Scopus for observational studies addressing the association between BMI and hot flash until August 2015. Data were independently extracted and analyzed using 95% odds ratio (OR), and confidence intervals (CI) based on the random-effects models. We identified 2,244 references and conducted seven studies with 4,219 participants. The association between hot flash and overweight was estimated 1.13 (95% CI: 0.97-1.32) and that of obesity was estimated 1.79 (95% CI: 1.52-2.11). No evidence of heterogeneity and publication bias was observed. This meta-analysis demonstrated that, though not to a great extent, obesity does increase the risk of hot flash. The findings from this meta-analysis indicated that obesity is associated with an increased risk of hot flash. Further large prospective cohort studies are required to provide convincing evidence as to whether or not BMI is associated with an increased risk of hot flashes.
Digital Device Architecture and the Safe Use of Flash Devices in Munitions
NASA Technical Reports Server (NTRS)
Katz, Richard B.; Flowers, David; Bergevin, Keith
2017-01-01
Flash technology is being utilized in fuzed munition applications and, based on the development of digital logic devices in the commercial world, usage of flash technology will increase. Digital devices of interest to designers include flash-based microcontrollers and field programmable gate arrays (FPGAs). Almost a decade ago, a study was undertaken to determine if flash-based microcontrollers could be safely used in fuzes and, if so, how should such devices be applied. The results were documented in the Technical Manual for the Use of Logic Devices in Safety Features. This paper will first review the Technical Manual and discuss the rationale behind the suggested architectures for microcontrollers and a brief review of the concern about data retention in flash cells. An architectural feature in the microcontroller under study will be discussed and its use will show how to screen for weak or failed cells during manufacture, storage, or immediately prior to use. As was done for microcontrollers a decade ago, architectures for a flash-based FPGA will be discussed, showing how it can be safely used in fuzes. Additionally, architectures for using non-volatile (including flash-based) storage will be discussed for SRAM-based FPGAs.
Bipolar cloud-to-ground lightning flash observations
NASA Astrophysics Data System (ADS)
Saba, Marcelo M. F.; Schumann, Carina; Warner, Tom A.; Helsdon, John H.; Schulz, Wolfgang; Orville, Richard E.
2013-10-01
lightning is usually defined as a lightning flash where the current waveform exhibits a polarity reversal. There are very few reported cases of cloud-to-ground (CG) bipolar flashes using only one channel in the literature. Reports on this type of bipolar flashes are not common due to the fact that in order to confirm that currents of both polarities follow the same channel to the ground, one necessarily needs video records. This study presents five clear observations of single-channel bipolar CG flashes. High-speed video and electric field measurement observations are used and analyzed. Based on the video images obtained and based on previous observations of positive CG flashes with high-speed cameras, we suggest that positive leader branches which do not participate in the initial return stroke of a positive cloud-to-ground flash later generate recoil leaders whose negative ends, upon reaching the branch point, traverse the return stroke channel path to the ground resulting in a subsequent return stroke of opposite polarity.
Waller, Francis Joseph; Quinn, Robert
2004-07-06
The present invention relates to a method of producing a diesel fuel blend having a pre-determined flash-point and a pre-determined increase in cetane number over the stock diesel fuel. Upon establishing the desired flash-point and increase in cetane number, an amount of a first oxygenate with a flash-point less than the flash-point of the stock diesel fuel and a cetane number equal to or greater than the cetane number of the stock diesel fuel is added to the stock diesel fuel in an amount sufficient to achieve the pre-determined increase in cetane number. Thereafter, an amount of a second oxygenate with a flash-point equal to or greater than the flash-point of the stock diesel fuel and a cetane number greater than the cetane number of the stock diesel fuel is added to the stock diesel fuel in an amount sufficient to achieve the pre-determined increase in cetane number.
Normalized Temperature Contrast Processing in Infrared Flash Thermography
NASA Technical Reports Server (NTRS)
Koshti, Ajay M.
2016-01-01
The paper presents further development in normalized contrast processing used in flash infrared thermography method. Method of computing normalized image or pixel intensity contrast, and normalized temperature contrast are provided. Methods of converting image contrast to temperature contrast and vice versa are provided. Normalized contrast processing in flash thermography is useful in quantitative analysis of flash thermography data including flaw characterization and comparison of experimental results with simulation. Computation of normalized temperature contrast involves use of flash thermography data acquisition set-up with high reflectivity foil and high emissivity tape such that the foil, tape and test object are imaged simultaneously. Methods of assessing other quantitative parameters such as emissivity of object, afterglow heat flux, reflection temperature change and surface temperature during flash thermography are also provided. Temperature imaging and normalized temperature contrast processing provide certain advantages over normalized image contrast processing by reducing effect of reflected energy in images and measurements, therefore providing better quantitative data. Examples of incorporating afterglow heat-flux and reflection temperature evolution in flash thermography simulation are also discussed.
On Stellar Flash Echoes from Circular Rings
NASA Astrophysics Data System (ADS)
Nemiroff, Robert; Mukherjee, Oindabi
2018-01-01
A flash -- or any episode of variability -- that occurs in the vicinity of a circular ring might be seen several times later, simultaneously, as echoes on the ring. Effective images of the flash are created and annihilated in pairs, with as many as four flash images visible concurrently. Videos detailing sequences of image pair creation, tandem motion, and subsequent image annihilation are shown, given simple opacity and scattering assumptions. It is proven that, surprisingly, images from a second pair creation event always annihilate with images from the first. Caustic surfaces between flash locations yielding two and four images are computed. Although such ring echos surely occur, their practical detection might be difficult as it could require dedicated observing programs involving sensitive photometry of extended objects. Potential flash sources include planetary and interstellar gas and dust rings near and around variable stars, flare stars, novae, supernovae, and GRBs. Potentially recoverable information includes size, distance, temporal history, and angular isotropy of both the ring and flash.
Comparison of geothermal power conversion cycles
NASA Technical Reports Server (NTRS)
Elliott, D. G.
1976-01-01
Geothermal power conversion cycles are compared with respect to recovery of the available wellhead power. The cycles compared are flash steam, in which steam turbines are driven by steam separated from one or more flash stages; binary, in which heat is transferred from the brine to an organic turbine cycle; flash binary, in which heat is transferred from flashed steam to an organic turbine cycle; and dual steam, in which two-phase expanders are driven by the flashing steam-brine mixture and steam turbines by the separated steam. Expander efficiencies assumed are 0.7 for steam turbines, 0.8 for organic turbines, and 0.6 for two-phase expanders. The fraction of available wellhead power delivered by each cycle is found to be about the same at all brine temperatures: 0.65 with one stage and 0.7 with four stages for dual stream; 0.4 with one stage and 0.6 with four stages for flash steam; 0.5 for binary; and 0.3 with one stage and 0.5 with four stages for flash binary.
Evaluation of 1.5-T Cell Flash Memory Total Ionizing Dose Response
NASA Astrophysics Data System (ADS)
Clark, Lawrence T.; Holbert, Keith E.; Adams, James W.; Navale, Harshad; Anderson, Blake C.
2015-12-01
Flash memory is an essential part of systems used in harsh environments, experienced by both terrestrial and aerospace TID applications. This paper presents studies of COTS flash memory TID hardness. While there is substantial literature on flash memory TID response, this work focuses for the first time on 1.5 transistor per cell flash memory. The experimental results show hardness varying from about 100 krad(Si) to over 250 krad(Si) depending on the usage model. We explore the circuit and device aspects of the results, based on the extensive reliability literature for this flash memory type. Failure modes indicate both device damage and circuit marginalities. Sector erase failure limits, but read only operation allows TID exceeding 200 krad(Si). The failures are analyzed by type.
Storm Physics and Lightning Properties over Northern Alabama during DC3
NASA Astrophysics Data System (ADS)
Matthee, R.; Carey, L. D.; Bain, A. L.
2013-12-01
The Deep Convective Clouds and Chemistry (DC3) experiment seeks to examine the relationship between deep moist convection (DMC) and the production of nitrogen oxides (NOx) via lightning (LNOx). The focus of this study will be to examine integrated storm microphysics and lightning properties of DMC across northern Alabama (NA) during the DC3 campaign through use of polarimetric radar [UAHuntsville's Advanced Radar for Meteorological and Operational Radar (ARMOR)] and lightning mapping [National Aeronautical and Space Administration's (NASA) north Alabama Lightning Mapping Array (NA LMA)] platforms. Specifically, ARMOR and NA LMA are being used to explore the ability of radar inferred microphysical (e.g., ice mass, graupel volume) measurements to parameterize flash rates (F) and flash area for estimation of LNOX production in cloud resolving models. The flash area was calculated by using the 'convex hull' method. This method essentially draws a polygon around all the sources that comprise a flash. From this polygon, the convex hull area that describes the minimum polygon that circumscribes the flash extent is calculated. Two storms have been analyzed so far; one on 21 May 2012 (S1) and another on 11 June 2012 (S2), both of which were aircraft-penetrated during DC3. For S1 and S2, radar reflectivity (Z) estimates of precipitation ice mass (M) within the mixed-phase zone (-10°C to -40°C) were well correlated to the trend of lightning flash rate. However, a useful radar-based F parameterization must provide accurate quantification of rates in addition to proper trends. The difference reflectivity was used to estimate Z associated with ice and then a single Z-M relation was employed to calculate M in the mixed-phase zone. Using this approach it was estimated that S1 produced an order of magnitude greater M, but produced about a third of the total amount of flashes compared to S2. Expectations based on the non-inductive charging (NIC) theory suggest that the M-to-F ratio (M/F) should be stable from storm-to-storm, amongst other factors, all else being equal. Further investigation revealed that the mean mixed-phase Z was 11 dB higher in S1 compared to S2, suggesting larger diameters and lower concentrations of ice particles in S1. Reduction by an order of magnitude of the intercept parameter (N0) of an assumed exponential ice particle size distribution within the Z-M relation for S1 resulted in a proportional reduction in S1's inferred M and therefore a more comparable M/F ratio between the storms. Flash statistics between S1 and S2 revealed the following: S1 produced 1.92 flashes/minute and a total of 102 flashes, while S2 produced 3.45 flashes/minute and a total of 307 flashes. On average, S1 (S2) produced 212 (78) sources per flash and an average flash area of 89.53 km2 (53.85 km2). Thus, S1 produced fewer flashes, a lower F, but more sources per flash and larger flash areas as compared to S2. Ongoing analysis is exploring the tuning of N0 within the Z-M relation by the mean Z in the mixed-phase zone. The suitability of various M estimates and other radar properties (graupel volume, ice fluxes, anvil ice mass) for parameterizing F, flash area and LNOX will be investigated on different storm types across NA.
NASA Astrophysics Data System (ADS)
Basarab, B.; Fuchs, B.; Rutledge, S. A.
2013-12-01
Predicting lightning activity in thunderstorms is important in order to accurately quantify the production of nitrogen oxides (NOx = NO + NO2) by lightning (LNOx). Lightning is an important global source of NOx, and since NOx is a chemical precursor to ozone, the climatological impacts of LNOx could be significant. Many cloud-resolving models rely on parameterizations to predict lightning and LNOx since the processes leading to charge separation and lightning discharge are not yet fully understood. This study evaluates predicted flash rates based on existing lightning parameterizations against flash rates observed for Colorado storms during the Deep Convective Clouds and Chemistry Experiment (DC3). Evaluating lightning parameterizations against storm observations is a useful way to possibly improve the prediction of flash rates and LNOx in models. Additionally, since convective storms that form in the eastern plains of Colorado can be different thermodynamically and electrically from storms in other regions, it is useful to test existing parameterizations against observations from these storms. We present an analysis of the dynamics, microphysics, and lightning characteristics of two case studies, severe storms that developed on 6 and 7 June 2012. This analysis includes dual-Doppler derived horizontal and vertical velocities, a hydrometeor identification based on polarimetric radar variables using the CSU-CHILL radar, and insight into the charge structure using observations from the northern Colorado Lightning Mapping Array (LMA). Flash rates were inferred from the LMA data using a flash counting algorithm. We have calculated various microphysical and dynamical parameters for these storms that have been used in empirical flash rate parameterizations. In particular, maximum vertical velocity has been used to predict flash rates in some cloud-resolving chemistry simulations. We diagnose flash rates for the 6 and 7 June storms using this parameterization and compare to observed flash rates. For the 6 June storm, a preliminary analysis of aircraft observations of storm inflow and outflow is presented in order to place flash rates (and other lightning statistics) in the context of storm chemistry. An approach to a possibly improved LNOx parameterization scheme using different lightning metrics such as flash area will be discussed.
NASA Astrophysics Data System (ADS)
MacGorman, D. R.; DiGangi, E.; Ziegler, C.; Biggerstaff, M. I.; Betten, D.; Bruning, E. C.
2014-12-01
A supercell thunderstorm was observed on 29 May 2012 during the Deep Convective Clouds and Chemistry (DC3) experiment. This storm was part of a cluster of severe storms and produced 5" hail, an EF-1 tornado, and copious lightning over the course of a few hours. During a period in which flash rates were increasing rapidly, observations were obtained from mobile polarimetric radars and a balloon-borne electric field meter (EFM) and particle imager, while aircraft sampled the chemistry of the inflow and anvil. In addition, the storm was within the domain of the 3-dimensional Oklahoma Lightning Mapping Array (LMA) and the S-band KTLX WSR-88D radar. The focus of this paper is the evolution of flash rates, the location of flash initiations, and the distribution of flash size and flash extent density as they relate to the evolving kinematics and microphysics of the storm for the approximately 30-minute period in which triple-Doppler coverage was available. Besides analyzing reflectivity structure and three-dimensional winds for the entire period, we examine mixing ratios of cloud water, cloud ice, rain, and graupel/hail that have been retrieved by a Lagrangian analysis for three select times, one each at the beginning, middle, and end of the period. Flashes in an around the updraft of this storm were typically small. Flash size tended to increase, and flash rates tended to decrease as distance from the updraft increased. Although flash initiations were most frequent near the updraft, some flashes were initiated near the edge of 30 dBZ cores and propagated into the anvil. Later, some flashes were initiated in the anvil itself, in vertical cells that formed and became electrified tens of kilometers downshear of the main body of the storm. Considerable lightning structure was inferred to be in regions dominated by cloud ice in the upper part of the storm. The continual small discharges in the overshooting top of the storm tended to be near or within 15 dBZ contours, although occasional discharges appeared to extend above the storm.
Mehrpooya, Maryam; Rabiee, Soghra; Larki-Harchegani, Amir; Fallahian, Amir-Mohammad; Moradi, Abbas; Ataei, Sara; Javad, Masoumeh Taravati
2018-01-01
Hot flashes are considered to be a common experience for menopausal women and they can compromise the quality of life. The objective of this study is to assess the efficacy of Cimicifuga racemosa in comparison with evening primrose oil (EPO) in postmenopausal women with menopause-related symptoms. This study was performed on 80 postmenopausal women with hot flashes. The participants were randomly divided into two groups by blocked randomization. The participants of one group received black cohosh and the other group received EPO for 8 weeks. The severity and number of hot flashes and quality of life were measured by four-point scale, and the Menopause-Specific Quality of Life (MENQOL) questionnaire at pre-intervention, 1 st , 4 th , and 8 th weeks after treatment. Data were analyzed in SPSS Version 16 using independent t -test, Chi-square, and Fisher's exact test. Average severity of hot flashes in both groups and number of hot flashes in black cohosh group in 8 th week were significantly lower than 1 st week ( P < 0.001), but number of hot flashes in primrose oil group in 8 th week showed no significant differences ( P = 0.32). The number of hot flashes and quality of life score in black cohosh arm compared to EPO showed a significant decrease in the 8 th week ( P < 0.05). All MENQOL scores were significantly improved in two groups ( P < 0.05), but the percentage of improvement in black cohosh arm was significantly superior to EPO group. Both herbs were effective in reduction of severity of hot flashes and improvement of the quality of life, but it seems that black cohosh is more effective than primrose oil because it was able to reduce the number of hot flashes too.
Mitochondrial flash as a novel biomarker of mitochondrial respiration in the heart.
Gong, Guohua; Liu, Xiaoyun; Zhang, Huiliang; Sheu, Shey-Shing; Wang, Wang
2015-10-01
Mitochondrial respiration through electron transport chain (ETC) activity generates ATP and reactive oxygen species in eukaryotic cells. The modulation of mitochondrial respiration in vivo or under physiological conditions remains elusive largely due to the lack of appropriate approach to monitor ETC activity in a real-time manner. Here, we show that ETC-coupled mitochondrial flash is a novel biomarker for monitoring mitochondrial respiration under pathophysiological conditions in cultured adult cardiac myocyte and perfused beating heart. Through real-time confocal imaging, we follow the frequency of a transient bursting fluorescent signal, named mitochondrial flash, from individual mitochondria within intact cells expressing a mitochondrial matrix-targeted probe, mt-cpYFP (mitochondrial-circularly permuted yellow fluorescent protein). This mt-cpYFP recorded mitochondrial flash has been shown to be composed of a major superoxide signal with a minor alkalization signal within the mitochondrial matrix. Through manipulating physiological substrates for mitochondrial respiration, we find a close coupling between flash frequency and the ETC electron flow, as measured by oxygen consumption rate in cardiac myocyte. Stimulating electron flow under physiological conditions increases flash frequency. On the other hand, partially block or slowdown electron flow by inhibiting the F0F1 ATPase, which represents a pathological condition, transiently increases then decreases flash frequency. Limiting electron entrance at complex I by knocking out Ndufs4, an assembling subunit of complex I, suppresses mitochondrial flash activity. These results suggest that mitochondrial electron flow can be monitored by real-time imaging of mitochondrial flash. The mitochondrial flash frequency could be used as a novel biomarker for mitochondrial respiration under physiological and pathological conditions. Copyright © 2015 the American Physiological Society.
NASA Astrophysics Data System (ADS)
Schultz, C. J.; Lang, T. J.; Leake, S.; Runco, M.; Blakeslee, R. J.
2017-12-01
Video and still frame images from cameras aboard the International Space Station (ISS) are used to inspire, educate, and provide a unique vantage point from low-Earth orbit that is second to none; however, these cameras have overlooked capabilities for contributing to scientific analysis of the Earth and near-space environment. The goal of this project is to study how georeferenced video/images from available ISS camera systems can be useful for scientific analysis, using lightning properties as a demonstration. Camera images from the crew cameras and high definition video from the Chiba University Meteor Camera were combined with lightning data from the National Lightning Detection Network (NLDN), ISS-Lightning Imaging Sensor (ISS-LIS), the Geostationary Lightning Mapper (GLM) and lightning mapping arrays. These cameras provide significant spatial resolution advantages ( 10 times or better) over ISS-LIS and GLM, but with lower temporal resolution. Therefore, they can serve as a complementarity analysis tool for studying lightning and thunderstorm processes from space. Lightning sensor data, Visible Infrared Imaging Radiometer Suite (VIIRS) derived city light maps, and other geographic databases were combined with the ISS attitude and position data to reverse geolocate each image or frame. An open-source Python toolkit has been developed to assist with this effort. Next, the locations and sizes of all flashes in each frame or image were computed and compared with flash characteristics from all available lightning datasets. This allowed for characterization of cloud features that are below the 4-km and 8-km resolution of ISS-LIS and GLM which may reduce the light that reaches the ISS-LIS or GLM sensor. In the case of video, consecutive frames were overlaid to determine the rate of change of the light escaping cloud top. Characterization of the rate of change in geometry, more generally the radius, of light escaping cloud top was integrated with the NLDN, ISS-LIS and GLM to understand how the peak rate of change and the peak area of each flash aligned with each lightning system in time. Flash features like leaders could be inferred from the video frames as well. Testing is being done to see if leader speeds may be accurately calculated under certain circumstances.
Wright, Timothy J; Vitale, Thomas; Boot, Walter R; Charness, Neil
2015-12-01
Recent empirical evidence has suggested that the flashes associated with red light running cameras (RLRCs) distract younger drivers, pulling attention away from the roadway and delaying processing of safety-relevant events. Considering the perceptual and attentional declines that occur with age, older drivers may be especially susceptible to the distracting effects of RLRC flashes, particularly in situations in which the flash is more salient (a bright flash at night compared with the day). The current study examined how age and situational factors potentially influence attention capture by RLRC flashes using covert (cuing effects) and overt (eye movement) indices of capture. We manipulated the salience of the flash by varying its luminance and contrast with respect to the background of the driving scene (either day or night scenes). Results of 2 experiments suggest that simulated RLRC flashes capture observers' attention, but, surprisingly, no age differences in capture were observed. However, an analysis examining early and late eye movements revealed that older adults may have been strategically delaying their eye movements in order to avoid capture. Additionally, older adults took longer to disengage attention following capture, suggesting at least 1 age-related disadvantage in capture situations. Findings have theoretical implications for understanding age differences in attention capture, especially with respect to capture in real-world scenes, and inform future work that should examine how the distracting effects of RLRC flashes influence driver behavior. (c) 2015 APA, all rights reserved).
Remote collection and analysis of witness reports on flash floods
NASA Astrophysics Data System (ADS)
Gourley, J. J.; Erlingis, J. M.; Smith, T. M.; Ortega, K. L.; Hong, Y.
2010-11-01
SummaryTypically, flash floods are studied ex post facto in response to a major impact event. A complement to field investigations is developing a detailed database of flash flood events, including minor events and null reports (i.e., where heavy rain occurred but there was no flash flooding), based on public survey questions conducted in near-real time. The Severe hazards analysis and verification experiment (SHAVE) has been in operation at the National Severe Storms Laboratory (NSSL) in Norman, OK, USA during the summers since 2006. The experiment employs undergraduate students to analyse real-time products from weather radars, target specific regions within the conterminous US, and poll public residences and businesses regarding the occurrence and severity of hail, wind, tornadoes, and now flash floods. In addition to providing a rich learning experience for students, SHAVE has also been successful in creating high-resolution datasets of severe hazards used for algorithm and model verification. This paper describes the criteria used to initiate the flash flood survey, the specific questions asked and information entered to the database, and then provides an analysis of results for flash flood data collected during the summer of 2008. It is envisioned that specific details provided by the SHAVE flash flood observation database will complement databases collected by operational agencies (i.e., US National Weather Service Storm Data reports) and thus lead to better tools to predict the likelihood of flash floods and ultimately reduce their impacts on society.
Mutational analysis of FLASH and PTPN13 genes in colorectal carcinomas.
Jeong, Eun Goo; Lee, Sung Hak; Yoo, Nam Jin; Lee, Sug Hyung
2008-01-01
The Fas-Fas ligand system is considered a major pathway for induction of apoptosis in cells and tissues. FLASH was identified as a pro-apoptotic protein that transmits apoptosis signal during Fas-mediated apoptosis. PTPN13 interacts with Fas and functions as both suppressor and inducer of Fas-mediated apoptosis. There are polyadenine tracts in both FLASH (A8 and A9 in exon 8) and PTPN13 (A8 in exon 7) genes that could be frameshift mutation targets in colorectal carcinomas. Because genes encoding proteins in Fas-mediated apoptosis frequently harbor somatic mutations in cancers, we explored the possibility as to whether mutations of FLASH and PTPN13 are a feature of colorectal carcinomas. We analysed human FLASH in exon 8 and PTPN13 in exon 7 for the detection of somatic mutations in 103 colorectal carcinomas by a polymerase chain reaction (PCR)- based single-strand conformation polymorphism (SSCP). We detected two mutations in FLASH gene, but none in PTPN13 gene. However, the two mutations were not frameshift (deletion or insertion) mutations in the polyadenine tracts of FLASH. The two mutations consisted of a deletion mutation (c.3734-3737delAGAA) and a missense mutation (c.3703A>C). These data indicate that frameshift mutation in the polyadenine tracts in both FLASH and PTPN13 genes is rare in colorectal carcinomas. Also, the data suggest that both FLASH and PTPN13 mutations in the polyadenine tracts may not have a crucial role in the pathogenesis of colorectal carcinomas.
Differentiation of debris-flow and flash-flood deposits: implications for paleoflood investigations
Waythomas, Christopher F.; Jarrett, Robert D.; ,
1993-01-01
Debris flows and flash floods are common geomorphic processes in the Colorado Rocky Mountain Front Range and foothills. Usually, debris flows and flash floods are associated with excess summer rainfall or snowmelt, in areas were unconsolidated surficial deposits are relatively thick and slopes are steep. In the Front Range and foothills, flash flooding is limited to areas below about 2300m whereas, debris flow activity is common throughout the foothill and alpine zones and is not necessarily elevation limited. Because flash floods and debris flows transport large quantities of bouldery sediment, the resulting deposits appear somewhat similar even though such deposits were produced by different processes. Discharge estimates based on debris-flow deposits interpreted as flash-flood deposits have large errors because techniques for discharge retrodiction were developed for water floods with negligible sediment concentrations. Criteria for differentiating between debris-flow and flash-flood deposits are most useful for deposits that are fresh and well-exposed. However, with the passage of time, both debris-flow and flash-flood deposits become modified by the combined effects of weathering, colluviation, changes in surface morphology, and in some instances removal of interstitial sediment. As a result, some of the physical characteristics of the deposits become more alike. Criteria especially applicable to older deposits are needed. We differentiate flash-flood from debris-flow and other deposits using clast fabric measurements and other morphologic and sedimentologic techniques (e.g., deposit morphology, clast lithology, particle size and shape, geomorphic setting).
Cloud-to-ground lightning in tropical cyclones: A study of Hurricanes Hugo (1989) and Jerry (1989)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Samsury, C.E.; Orville, R.E.
1994-08-01
Cloud-to-ground lightning characteristics of two Atlantic tropical cyclones of 1989, Hurricanes Hugo and Jerry, are presented. Statistics on the number of flashes, location, polarity, peak currents, and multiplicity (number of strokes per flash) are examined in an 18-h period divided into prelandfall and postlandfall categories. Land-based and aircraft lower fuselage radar data are also analyzed to determine the nature of the precipitation in which lightning is detected. Jerry is found to be more electrically active than Hugo, with 691 flashes detected compared with 33 flashes for Hugo. The majority of these flashes, regardless of the polarity, are located in themore » right front and right rear quadrants of the hurricanes, almost exclusively in outer convective rainbands. One reason for the large difference in the number of flashes between the two storms is the presence of many convective rainbands in Jerry, compared to only a few in Hugo. More than 20% of the flashes in each storm have a positive polarity. Median negative peak currents of the first return strokes are 49 kA in Hugo and 40 kA in Jerry. Median positive peak currents are 65 kA in Hugo and 52 kA in Jerry. The mean multiplicity of the negative flashes is 1.7 in Hugo and 2.6 in Jerry. Twenty percent of the negative flashes detected in Jerry have a multiplicity of 4 or higher.« less
Wright, Timothy J.; Vitale, Thomas; Boot, Walter R; Charness, Neil
2015-01-01
Recent empirical evidence suggests that the flashes associated with red light running cameras (RLRCs) distract younger drivers, pulling attention away from the roadway and delaying processing of safety-relevant events. Considering the perceptual and attentional declines that occur with age, older drivers may be especially susceptible to the distracting effects of RLRC flashes, particularly in situations in which the flash is more salient (a bright flash at night compared to the day). The current study examined how age and situational factors potentially influence attention capture by RLRC flashes using covert (cuing effects) and overt (eye movement) indices of capture. We manipulated the salience of the flash by varying its luminance and contrast with respect to the background of the driving scene (either day or night scenes). Results of two experiments suggest that simulated RLRC flashes capture observers' attention, but, surprisingly, no age differences in capture were observed. However, an analysis examining early and late eye movements revealed that older adults may have been strategically delaying their eye movements in order to avoid capture. Additionally, older adults took longer to disengage attention following capture, suggesting at least one age-related disadvantage in capture situations. Findings have theoretical implications for understanding age differences in attention capture, especially with respect to capture in real-world scenes, and inform future work that should examine how the distracting effects of RLRC flashes influence driver behavior. PMID:26479014
Genetic polymorphisms, hormone levels, and hot flashes in midlife women.
Schilling, Chrissy; Gallicchio, Lisa; Miller, Susan R; Langenberg, Patricia; Zacur, Howard; Flaws, Jodi A
2007-06-20
Hot flashes disrupt the lives of millions of women each year. Although hot flashes are a public health concern, little is known about risk factors that predispose women to hot flashes. Thus, the objective of this study was to examine whether sex steroid hormone levels and genetic polymorphisms in hormone biosynthesis and degradation enzymes are associated with the risk of hot flashes. In a cross-sectional study design, midlife women aged 45-54 years (n=639) were recruited from Baltimore and its surrounding counties. Participants completed a questionnaire and donated a blood sample for steroid hormone analysis and genotyping. The associations between genetic polymorphisms and hormone levels, as well as the associations between genetic polymorphisms, hormone levels, and hot flashes were examined using statistical models. A polymorphism in CYP1B1 was associated with lower dehydroepiandrosterone-sulfate (DHEA-S) and progesterone levels, while a polymorphism in CYP19 (aromatase) was associated with higher testosterone and DHEA-S levels. Lower progesterone and sex hormone binding globulin levels, lower free estradiol index, and a higher ratio of total androgens to total estrogens were associated with the experiencing of hot flashes. A polymorphism in CYP1B1 and a polymorphism in 3betaHSD were both associated with hot flashes. Some genetic polymorphisms may be associated with altered levels of hormones in midlife women. Further, selected genetic polymorphisms and altered hormone levels may be associated with the risk of hot flashes in midlife women.
Long-term Stability of the WFC3 Post-Flash LED Lamp
NASA Astrophysics Data System (ADS)
Martlin, Catherine; Baggett, Sylvia M.
2017-06-01
We report the results of a study of the long-term stability of the LED lamp used in post-flashing WFC3/UVIS images (Martlin, C and Baggett, S., 2017). Having analyzed 644 sub-array exposures taken over the course of just over 3 years we find no significant long-term trends in the LED lamp brightness. The average percentage change per year over all FLASH level and shutter combinations is found to be 0.15% per year with an uncertainty of +/- 0.24% per year. The maximum measured percentage change per year was 0.39% for the highest FLASH level of 20 e- on shutter A which would indicate a change of less than 1 e-/pixel over the roughly 3 years since post-flashing began.There are, however, occasional short-term deviations in the LED output. The average minimum and maximum outliers over all FLASH level and shutter combination subsets are 4.1% below and 3.5% above, respectively, the mean of that subset. The maximum outlier over all the sets is 5.8% above the normalized mean value, for FLASH level 3/shutter A. The minimum outlier over all sets is also for FLASH level 3/shutter A and is 8.9% below the normalized mean value. Investigation of these outliers has revealed no systematic cause for the excursions and we recommend that users continue using the post-flash as they would have previously.
Xu, Zhanfeng; Bunker, Christopher E; Harrington, Peter de B
2010-11-01
Monitoring the changes of jet fuel physical properties is important because fuel used in high-performance aircraft must meet rigorous specifications. Near-infrared (NIR) spectroscopy is a fast method to characterize fuels. Because of the complexity of NIR spectral data, chemometric techniques are used to extract relevant information from spectral data to accurately classify physical properties of complex fuel samples. In this work, discrimination of fuel types and classification of flash point, freezing point, boiling point (10%, v/v), boiling point (50%, v/v), and boiling point (90%, v/v) of jet fuels (JP-5, JP-8, Jet A, and Jet A1) were investigated. Each physical property was divided into three classes, low, medium, and high ranges, using two evaluations with different class boundary definitions. The class boundaries function as the threshold to alarm when the fuel properties change. Optimal partial least squares discriminant analysis (oPLS-DA), fuzzy rule-building expert system (FuRES), and support vector machines (SVM) were used to build the calibration models between the NIR spectra and classes of physical property of jet fuels. OPLS-DA, FuRES, and SVM were compared with respect to prediction accuracy. The validation of the calibration model was conducted by applying bootstrap Latin partition (BLP), which gives a measure of precision. Prediction accuracy of 97 ± 2% of the flash point, 94 ± 2% of freezing point, 99 ± 1% of the boiling point (10%, v/v), 98 ± 2% of the boiling point (50%, v/v), and 96 ± 1% of the boiling point (90%, v/v) were obtained by FuRES in one boundaries definition. Both FuRES and SVM obtained statistically better prediction accuracy over those obtained by oPLS-DA. The results indicate that combined with chemometric classifiers NIR spectroscopy could be a fast method to monitor the changes of jet fuel physical properties.
Evaluating Non-In-Place Update Techniques for Flash-Based Transaction Processing Systems
NASA Astrophysics Data System (ADS)
Wang, Yongkun; Goda, Kazuo; Kitsuregawa, Masaru
Recently, flash memory is emerging as the storage device. With price sliding fast, the cost per capacity is approaching to that of SATA disk drives. So far flash memory has been widely deployed in consumer electronics even partly in mobile computing environments. For enterprise systems, the deployment has been studied by many researchers and developers. In terms of the access performance characteristics, flash memory is quite different from disk drives. Without the mechanical components, flash memory has very high random read performance, whereas it has a limited random write performance because of the erase-before-write design. The random write performance of flash memory is comparable with or even worse than that of disk drives. Due to such a performance asymmetry, naive deployment to enterprise systems may not exploit the potential performance of flash memory at full blast. This paper studies the effectiveness of using non-in-place-update (NIPU) techniques through the IO path of flash-based transaction processing systems. Our deliberate experiments using both open-source DBMS and commercial DBMS validated the potential benefits; x3.0 to x6.6 performance improvement was confirmed by incorporating non-in-place-update techniques into file system without any modification of applications or storage devices.
FLASH LIDAR Based Relative Navigation
NASA Technical Reports Server (NTRS)
Brazzel, Jack; Clark, Fred; Milenkovic, Zoran
2014-01-01
Relative navigation remains the most challenging part of spacecraft rendezvous and docking. In recent years, flash LIDARs, have been increasingly selected as the go-to sensors for proximity operations and docking. Flash LIDARS are generally lighter and require less power that scanning Lidars. Flash LIDARs do not have moving parts, and they are capable of tracking multiple targets as well as generating a 3D map of a given target. However, there are some significant drawbacks of Flash Lidars that must be resolved if their use is to be of long-term significance. Overcoming the challenges of Flash LIDARs for navigation-namely, low technology readiness level, lack of historical performance data, target identification, existence of false positives, and performance of vision processing algorithms as intermediaries between the raw sensor data and the Kalman filter-requires a world-class testing facility, such as the Lockheed Martin Space Operations Simulation Center (SOSC). Ground-based testing is a critical step for maturing the next-generation flash LIDAR-based spacecraft relative navigation. This paper will focus on the tests of an integrated relative navigation system conducted at the SOSC in January 2014. The intent of the tests was to characterize and then improve the performance of relative navigation, while addressing many of the flash LIDAR challenges mentioned above. A section on navigation performance and future recommendation completes the discussion.
Simulated CONUS Flash Flood Climatologies from Distributed Hydrologic Models
NASA Astrophysics Data System (ADS)
Flamig, Z.; Gourley, J. J.; Vergara, H. J.; Kirstetter, P. E.; Hong, Y.
2016-12-01
This study will describe a CONUS flash flood climatology created over the period from 2002 through 2011. The MRMS reanalysis precipitation dataset was used as forcing into the Ensemble Framework For Flash Flood Forecasting (EF5). This high resolution 1-sq km 5-minute dataset is ideal for simulating flash floods with a distributed hydrologic model. EF5 features multiple water balance components including SAC-SMA, CREST, and a hydrophobic model all coupled with kinematic wave routing. The EF5/SAC-SMA and EF5/CREST water balance schemes were used for the creation of dual flash flood climatologies based on the differing water balance principles. For the period from 2002 through 2011 the daily maximum streamflow, unit streamflow, and time of peak streamflow was stored along with the minimum soil moisture. These variables are used to describe the states of the soils right before a flash flood event and the peak streamflow that was simulated during the flash flood event. The results will be shown, compared and contrasted. The resulting model simulations will be verified on basins less than 1,000-sq km with USGS gauges to ensure the distributed hydrologic models are reliable. The results will also be compared spatially to Storm Data flash flood event observations to judge the degree of agreement between the simulated climatologies and observations.
Perceived shifts of flashed stimuli by visible and invisible object motion.
Watanabe, Katsumi; Sato, Takashi R; Shimojo, Shinsuke
2003-01-01
Perceived positions of flashed stimuli can be altered by motion signals in the visual field-position capture (Whitney and Cavanagh, 2000 Nature Neuroscience 3 954-959). We examined whether position capture of flashed stimuli depends on the spatial relationship between moving and flashed stimuli, and whether the phenomenal permanence of a moving object behind an occluding surface (tunnel effect; Michotte 1950 Acta Psychologica 7 293-322) can produce position capture. Observers saw two objects (circles) moving vertically in opposite directions, one in each visual hemifield. Two horizontal bars were simultaneously flashed at horizontally collinear positions with the fixation point at various timings. When the movement of the object was fully visible, the flashed bar appeared shifted in the motion direction of the circle. But this position-capture effect occurred only when the bar was presented ahead of or on the moving circle. Even when the motion trajectory was covered by an opaque surface and the bar was flashed after complete occlusion of the circle, the position-capture effect was still observed, though the positional asymmetry was less clear. These results show that movements of both visible and 'hidden' objects can modulate the perception of positions of flashed stimuli and suggest that a high-level representation of 'objects in motion' plays an important role in the position-capture effect.
Increasing flash droughts over China during the recent global warming hiatus
Wang, Linying; Yuan, Xing; Xie, Zhenghui; Wu, Peili; Li, Yaohui
2016-01-01
The recent global warming slowdown or hiatus after the big El Niño event in 1997/98 raises the questions of whether terrestrial hydrological cycle is being decelerated and how do the hydrological extremes respond to the hiatus. However, the rapidly developing drought events that are termed as “flash droughts” accompanied by extreme heat, low soil moisture and high evapotranspiration (ET), occurred frequently around the world, and caused devastating impacts on crop yields and water supply. Here, we investigate the long-term trend and variability of flash droughts over China. Flash droughts are most likely to occur over humid and semi-humid regions, such as southern and northeastern China. Flash drought averaged over China increased by 109% from 1979 to 2010, and the increase was mainly due to a long term warming of temperature (50%), followed by the contributions from decreasing soil moisture and increasing ET. There was a slight drop in temperature after 1997, but the increasing trend of flash droughts was tripled. Further results indicate that the decreasing temperature was compensated by the accelerated drying trends of soil moisture and enhanced ET, leading to an acceleration of flash droughts during the warming hiatus. The anthropogenic warming in the next few decades may exacerbate future flash drought conditions in China. PMID:27513724
Cellini, Cristiano; Scocchia, Lisa; Drewing, Knut
2016-10-01
In the flash-lag illusion, a brief visual flash and a moving object presented at the same location appear to be offset with the flash trailing the moving object. A considerable amount of studies investigated the visual flash-lag effect, and flash-lag-like effects have also been observed in audition, and cross-modally between vision and audition. In the present study, we investigate whether a similar effect can also be observed when using only haptic stimuli. A fast vibration (or buzz, lasting less than 20 ms) was applied to the moving finger of the observers and employed as a "haptic flash." Participants performed a two-alternative forced-choice (2AFC) task where they had to judge whether the moving finger was located to the right or to the left of the stationary finger at the time of the buzz. We used two different movement velocities (Slow and Fast conditions). We found that the moving finger was systematically misperceived to be ahead of the stationary finger when the two were physically aligned. This result can be interpreted as a purely haptic analogue of the flash-lag effect, which we refer to as "buzz-lag effect." The buzz-lag effect can be well accounted for by the temporal-sampling explanation of flash-lag-like effects.
Flashes and floaters - a practical approach to assessment and management.
Kahawita, Shyalle; Simon, Sumu; Gilhotra, Jolly
2014-04-01
Flashes and floaters are common ophthalmic issues for which patients may initially present to their general practitioner. It may be a sign of benign, age-related changes of the vitreous or more serious retinal detachment. This article provides a guide to the assessment and management of a patient presenting with flashes and floaters. Although most patients presenting with flashes and floaters have benign age-related changes, they must be referred to an ophthalmologist to rule out sight-threatening conditions. Key examination features include the nature of the flashes and floaters, whether one or both eyes are affected and changes in visual acuity or visual field.
An Improved B+ Tree for Flash File Systems
NASA Astrophysics Data System (ADS)
Havasi, Ferenc
Nowadays mobile devices such as mobile phones, mp3 players and PDAs are becoming evermore common. Most of them use flash chips as storage. To store data efficiently on flash, it is necessary to adapt ordinary file systems because they are designed for use on hard disks. Most of the file systems use some kind of search tree to store index information, which is very important from a performance aspect. Here we improved the B+ search tree algorithm so as to make flash devices more efficient. Our implementation of this solution saves 98%-99% of the flash operations, and is now the part of the Linux kernel.
NASA Astrophysics Data System (ADS)
Klingenberg, Guenter; Heimerl, Joseph M.
A repository of fundamental experimental and analytical data concerning the complex phenomena associated with gun-muzzle blast and flash effects is presented, proceeding from gun muzzle signatures to modern gun-propulsion concepts, interior and transitional ballistics, and characterizations of blast-wave research and muzzle flash. Data are presented in support of a novel hypothesis which explains the ignition of secondary flash and elucidates the means for its suppression. Both chemical and mechanical (often competing) methods of flash suppression are treated. The historical work of Kesslau and Ladenburg is noted, together with French, British, Japanese and American research efforts and current techniques of experimental characterization for gun muzzle phenomena.
Lightning rates relative to tornadic storm evolution on 22 May 1981
NASA Technical Reports Server (NTRS)
Macgorman, Donald R.; Burgess, Donald W.; Mazur, Vladislav; Rust, W. David; Taylor, William L.
1989-01-01
Lightning and Doppler radar data for two tornadic storms in Oklahoma on May 22, 1981 are used to analyze ground flash rates relative to the time of tornadoes. It is found that the ground flash rates had no obvious relationship with the tornado times, although the stroke rate in both storms was greatest after the tornadic stage ended. The variations in the cyclone shear and the intracloud flash rates within 10 km of the mesocyclone region are examined. The results suggest that most tornadic storms have an increase in total flash rates near the time of the tornado and that this increase is often dominated by intracloud flashes.
Simulation of flashing signal operations.
DOT National Transportation Integrated Search
1982-01-01
Various guidelines that have been proposed for the operation of traffic signals in the flashing mode were reviewed. The use of existing traffic simulation procedures to evaluate flashing signals was examined and a study methodology for simulating and...
DefenseLink Special: Doolittle Raid, April 18, 1942
enhanced viewing {Flash 8} Macromedia Flash Player 8 required Download free Macromedia Flash Player Download free Internet Explorer DOOLITTLE RAIDERS Â Retired Lt. Col. Chase Nelson, a Doolittle Raider
Hot flashes, core body temperature, and metabolic parameters in breast cancer survivors.
Carpenter, Janet S; Gilchrist, Janet M; Chen, Kong; Gautam, Shiva; Freedman, Robert R
2004-01-01
To examine core body temperature, energy expenditure, and respiratory quotient among breast cancer survivors experiencing hot flashes and compare these data to published studies from healthy women. In an observational study, nine breast cancer survivors with daily hot flashes who met specified criteria spent 24 hours in a temperature- and humidity-controlled whole-room indirect calorimeter (ie, metabolic room). Demographic and disease/treatment information were obtained and the following were measured: hot flashes via sternal skin conductance monitoring (sampled every second); core body temperature via an ingested radiotelemetry pill (sampled every 10 seconds); and energy expenditure and respiratory quotient via a whole-room indirect calorimeter (calculated every minute). Circadian analysis of core temperature indicated wide variability with disrupted circadian rhythm noted in all women. Core temperature began to rise 20 minutes pre-flash to 7 minutes pre-flash (0.09 degrees C increase). Increases in energy expenditure and respiratory quotient increased with each hot flash. Findings are comparable to published data from healthy women and warrant replication in larger, more diverse samples of women treated for breast cancer.
A Method to Measure and Estimate Normalized Contrast in Infrared Flash Thermography
NASA Technical Reports Server (NTRS)
Koshti, Ajay M.
2016-01-01
The paper presents further development in normalized contrast processing used in flash infrared thermography method. Method of computing normalized image or pixel intensity contrast, and normalized temperature contrast are provided. Methods of converting image contrast to temperature contrast and vice versa are provided. Normalized contrast processing in flash thermography is useful in quantitative analysis of flash thermography data including flaw characterization and comparison of experimental results with simulation. Computation of normalized temperature contrast involves use of flash thermography data acquisition set-up with high reflectivity foil and high emissivity tape such that the foil, tape and test object are imaged simultaneously. Methods of assessing other quantitative parameters such as emissivity of object, afterglow heat flux, reflection temperature change and surface temperature during flash thermography are also provided. Temperature imaging and normalized temperature contrast processing provide certain advantages over normalized image contrast processing by reducing effect of reflected energy in images and measurements, therefore providing better quantitative data. Examples of incorporating afterglow heat-flux and reflection temperature evolution in flash thermography simulation are also discussed.
Does underwater flash photography affect the behaviour, movement and site persistence of seahorses?
Harasti, D; Gladstone, W
2013-11-01
The effect of flash photography on seahorse species has never been tested. An experiment was established to test the effect of flash photography and the handling of Hippocampus whitei, a medium-sized seahorse species endemic to Australia, on their behavioural responses, movements and site persistence. A total of 24 H. whitei were utilized in the experiment with eight in each of the three treatments (flash photography, handling and control). The effect of underwater flash photography on H. whitei movements was not significant; however, the effect of handling H. whitei to take a photograph had a significant effect on their short-term behavioural responses to the photographer. Kaplan-Meier log-rank test revealed that there was no significant difference in site persistence of H. whitei from each of the three treatments and that flash photography had no long-term effects on their site persistence. It is concluded that the use of flash photography by divers is a safe and viable technique with H. whitei, particularly if photographs can be used for individual identification purposes. © 2013 The Fisheries Society of the British Isles.
CCD high-speed videography system with new concepts and techniques
NASA Astrophysics Data System (ADS)
Zheng, Zengrong; Zhao, Wenyi; Wu, Zhiqiang
1997-05-01
A novel CCD high speed videography system with brand-new concepts and techniques is developed by Zhejiang University recently. The system can send a series of short flash pulses to the moving object. All of the parameters, such as flash numbers, flash durations, flash intervals, flash intensities and flash colors, can be controlled according to needs by the computer. A series of moving object images frozen by flash pulses, carried information of moving object, are recorded by a CCD video camera, and result images are sent to a computer to be frozen, recognized and processed with special hardware and software. Obtained parameters can be displayed, output as remote controlling signals or written into CD. The highest videography frequency is 30,000 images per second. The shortest image freezing time is several microseconds. The system has been applied to wide fields of energy, chemistry, medicine, biological engineering, aero- dynamics, explosion, multi-phase flow, mechanics, vibration, athletic training, weapon development and national defense engineering. It can also be used in production streamline to carry out the online, real-time monitoring and controlling.
The Forensic Potential of Flash Memory
2009-09-01
limit range of 10 to 100 years before data is lost [12]. 5. Flash Memory Logical Structure The logical structure of flash memory from least to...area is not standardized and is manufacturer specific. This information will be used by the wear leveling algorithms and as such will be proprietary...memory cells, the manufacturers of the flash implement a wear leveling algorithm . In contrast, a magnetic disk in an overwrite operation will reuse the
Abu-Ghosh, Said; Fixler, Dror; Dubinsky, Zvy; Iluz, David
2015-01-01
Under specific conditions, flashing light enhances the photosynthesis rate in comparison to continuous illumination. Here we show that a combination of flashing light and continuous background light with the same integrated photon dose as continuous or flashing light alone can be used to significantly enhance photosynthesis and increase microalgae growth. To test this hypothesis, the green microalga Dunaliella salina was exposed to three different light regimes: continuous light, flashing light, and concomitant application of both. Algal growth was compared under three different integrated light quantities; low, intermediate, and moderately high. Under the combined light regime, there was a substantial increase in all algal growth parameters, with an enhanced photosynthesis rate, within 3days. Our strategy demonstrates a hitherto undescribed significant increase in photosynthesis and algal growth rates, which is beyond the increase by flashing light alone. Copyright © 2015 Elsevier Ltd. All rights reserved.
Saha, Kaushik; Som, Sibendu; Battistoni, Michele
2017-01-01
Flash boiling is known to be a common phenomenon for gasoline direct injection (GDI) engine sprays. The Homogeneous Relaxation Model has been adopted in many recent numerical studies for predicting cavitation and flash boiling. The Homogeneous Relaxation Model is assessed in this study. Sensitivity analysis of the model parameters has been documented to infer the driving factors for the flash-boiling predictions. The model parameters have been varied over a range and the differences in predictions of the extent of flashing have been studied. Apart from flashing in the near nozzle regions, mild cavitation is also predicted inside the gasoline injectors.more » The variation in the predicted time scales through the model parameters for predicting these two different thermodynamic phenomena (cavitation, flash) have been elaborated in this study. Turbulence model effects have also been investigated by comparing predictions from the standard and Re-Normalization Group (RNG) k-ε turbulence models.« less
NELIOTA: First temperature measurement of lunar impact flashes
NASA Astrophysics Data System (ADS)
Bonanos, A. Z.; Avdellidou, C.; Liakos, A.; Xilouris, E. M.; Dapergolas, A.; Koschny, D.; Bellas-Velidis, I.; Boumis, P.; Charmandaris, V.; Fytsilis, A.; Maroussis, A.
2018-04-01
We report the first scientific results from the NELIOTA (NEO Lunar Impacts and Optical TrAnsients) project, which has recently begun lunar monitoring observations with the 1.2-m Kryoneri telescope. NELIOTA aims to detect faint impact flashes produced by near-Earth meteoroids and asteroids and thereby help constrain the size-frequency distribution of near-Earth objects in the decimeter to meter range. The NELIOTA setup, consisting of two fast-frame cameras observing simultaneously in the R and I bands, enables - for the first time - direct analytical calculation of the flash temperatures. We present the first ten flashes detected, for which we find temperatures in the range 1600 to 3100 K, in agreement with theoretical values. Two of these flashes were detected on multiple frames in both filters and therefore yield the first measurements of the temperature drop for lunar flashes. In addition, we compute the impactor masses, which range between 100 g and 50 kg.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saha, Kaushik; Som, Sibendu; Battistoni, Michele
Flash boiling is known to be a common phenomenon for gasoline direct injection (GDI) engine sprays. The Homogeneous Relaxation Model has been adopted in many recent numerical studies for predicting cavitation and flash boiling. The Homogeneous Relaxation Model is assessed in this study. Sensitivity analysis of the model parameters has been documented to infer the driving factors for the flash-boiling predictions. The model parameters have been varied over a range and the differences in predictions of the extent of flashing have been studied. Apart from flashing in the near nozzle regions, mild cavitation is also predicted inside the gasoline injectors.more » The variation in the predicted time scales through the model parameters for predicting these two different thermodynamic phenomena (cavitation, flash) have been elaborated in this study. Turbulence model effects have also been investigated by comparing predictions from the standard and Re-Normalization Group (RNG) k-ε turbulence models.« less
FLASH free-electron laser single-shot temporal diagnostic: terahertz-field-driven streaking.
Ivanov, Rosen; Liu, Jia; Brenner, Günter; Brachmanski, Maciej; Düsterer, Stefan
2018-01-01
The commissioning of a terahertz-field-driven streak camera installed at the free-electron laser (FEL) FLASH at DESY in Hamburg, being able to deliver photon pulse duration as well as arrival time information with ∼10 fs resolution for each single XUV FEL pulse, is reported. Pulse durations between 300 fs and <15 fs have been measured for different FLASH FEL settings. A comparison between the XUV pulse arrival time and the FEL electron bunch arrival time measured at the FLASH linac section exhibits a correlation width of 20 fs r.m.s., thus demonstrating the excellent operation stability of FLASH. In addition, the terahertz-streaking setup was operated simultaneously to an alternative method to determine the FEL pulse duration based on spectral analysis. FLASH pulse duration derived from simple spectral analysis is in good agreement with that from terahertz-streaking measurement.
Organic flash cycles for efficient power production
Ho, Tony; Mao, Samuel S.; Greif, Ralph
2016-03-15
This disclosure provides systems, methods, and apparatus related to an Organic Flash Cycle (OFC). In one aspect, a modified OFC system includes a pump, a heat exchanger, a flash evaporator, a high pressure turbine, a throttling valve, a mixer, a low pressure turbine, and a condenser. The heat exchanger is coupled to an outlet of the pump. The flash evaporator is coupled to an outlet of the heat exchanger. The high pressure turbine is coupled to a vapor outlet of the flash evaporator. The throttling valve is coupled to a liquid outlet of the flash evaporator. The mixer is coupled to an outlet of the throttling valve and to an outlet of the high pressure turbine. The low pressure turbine is coupled to an outlet of the mixer. The condenser is coupled to an outlet of the low pressure turbine and to an inlet of the pump.
Lunar Impact Flash Locations from NASA's Lunar Impact Monitoring Program
NASA Technical Reports Server (NTRS)
Moser, D. E.; Suggs, R. M.; Kupferschmidt, L.; Feldman, J.
2015-01-01
Meteoroids are small, natural bodies traveling through space, fragments from comets, asteroids, and impact debris from planets. Unlike the Earth, which has an atmosphere that slows, ablates, and disintegrates most meteoroids before they reach the ground, the Moon has little-to-no atmosphere to prevent meteoroids from impacting the lunar surface. Upon impact, the meteoroid's kinetic energy is partitioned into crater excavation, seismic wave production, and the generation of a debris plume. A flash of light associated with the plume is detectable by instruments on Earth. Following the initial observation of a probable Taurid impact flash on the Moon in November 2005,1 the NASA Meteoroid Environment Office (MEO) began a routine monitoring program to observe the Moon for meteoroid impact flashes in early 2006, resulting in the observation of over 330 impacts to date. The main objective of the MEO is to characterize the meteoroid environment for application to spacecraft engineering and operations. The Lunar Impact Monitoring Program provides information about the meteoroid flux in near-Earth space in a size range-tens of grams to a few kilograms-difficult to measure with statistical significance by other means. A bright impact flash detected by the program in March 2013 brought into focus the importance of determining the impact flash location. Prior to this time, the location was estimated to the nearest half-degree by visually comparing the impact imagery to maps of the Moon. Better accuracy was not needed because meteoroid flux calculations did not require high-accuracy impact locations. But such a bright event was thought to have produced a fresh crater detectable from lunar orbit by the NASA spacecraft Lunar Reconnaissance Orbiter (LRO). The idea of linking the observation of an impact flash with its crater was an appealing one, as it would validate NASA photometric calculations and crater scaling laws developed from hypervelocity gun testing. This idea was dependent upon LRO finding a fresh impact crater associated with one of the impact flashes recorded by Earth-based instruments, either the bright event of March 2013 or any other in the database of impact observations. To find the crater, LRO needed an accurate area to search. This Technical Memorandum (TM) describes the geolocation technique developed to accurately determine the impact flash location, and by association, the location of the crater, thought to lie directly beneath the brightest portion of the flash. The workflow and software tools used to geolocate the impact flashes are described in detail, along with sources of error and uncertainty and a case study applying the workflow to the bright impact flash in March 2013. Following the successful geolocation of the March 2013 flash, the technique was applied to all impact flashes detected by the MEO between November 7, 2005, and January 3, 2014.
Accessible or Inaccessible? Diagnostic Efficacy of CT-Guided Core Biopsies of Head and Neck Masses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cunningham, Jane D., E-mail: janecunningham0708@gmail.com; McCusker, Mark W.; Power, Sarah
PurposeTissue sampling of lesions in the head and neck is challenging due to complex regional anatomy and sometimes necessitates open surgical biopsy. However, many patients are poor surgical candidates due to comorbidity. Thus, we evaluated the use of CT guidance for establishing histopathological diagnosis of head and neck masses.MethodsAll consecutive patients (n = 22) who underwent CT-guided core biopsy of head or neck masses between April 2009 and August 2012 were retrospectively reviewed using the departmental CT interventional procedures database. The indication for each biopsy performed was to establish or exclude a diagnosis of neoplasia in patients with suspicious head or neckmore » lesions found on clinical examination or imaging studies. Patients received conscious sedation and 18 G, semiautomated core needle biopsies were performed by experienced neuroradiologists using 16-slice multidetector row CT imaging guidance (Somatom Definition Siemens Medical Solutions, Germany). Histopathology results of each biopsy were analysed.ResultsSixteen of 22 biopsies that were performed (73 %) yielded a pathological diagnosis. Anatomic locations biopsied included: masticator (n = 7), parapharyngeal (n = 3), parotid (n = 3), carotid (n = 3), perivertebral (n = 3), pharyngeal (n = 2), and retropharyngeal (n = 1) spaces. Six biopsies (27 %) were nondiagnostic due to inadequate tissue sampling, particularly small biopsy sample size and failure to biopsy the true sampling site due to extensive necrosis. No major complications were encountered.ConclusionsThe use of CT guidance to perform core biopsies of head and neck masses is an effective means of establishing histopathological diagnosis and reduces the need for diagnostic open surgical biopsy and general anaesthesia.« less
Noll, Dariusz; Kruk, Mariusz; Pręgowski, Jerzy; Kaczmarska, Edyta; Kryczka, Karolina; Pracoń, Radosław; Skwarek, Mirosław; Dzielińska, Zofia; Petryka, Joanna; Spiewak, Mateusz; Lubiszewska, Barbara; Norwa-Otto, Bożena; Opolski, Maksymilian; Witkowski, Adam; Demkow, Marcin; Rużyłło, Witold; Kępka, Cezary
2013-01-01
Computed tomography coronary angiography (CTCA) is a diagnostic method used for exclusion of coronary artery disease. However, lower accuracy of CTCA in assessment of calcified lesions is a significant factor impeding applicability of CTCA for assessment of coronary atherosclerosis. To provide insight into lumen and calcium characteristics assessed with CTCA, we compared these parameters to the reference of intravascular ultrasound (IVUS). Two hundred and fifty-two calcified lesions within 97 arteries of 60 patients (19 women, age 63 ±10 years) underwent assessment with both 2 × 64 slice CT (Somatom Definition, Siemens) and IVUS (s5, Volcano Corp.). Coronary lumen and calcium dimensions within calcified lesions were assessed with CTCA and compared to the reference measurements made with IVUS. On average CTCA underestimated mean lumen diameter (2.8 ±0.7 mm vs. 2.9 ±0.8 mm for IVUS), lumen area (6.4 ±3.4 mm(2) vs. 7.0 ±3.7 mm(2) for IVUS, p < 0.001) and total calcium arc (52 ±35° vs. 83 ±54°). However, analysis of tertiles of the examined parameters revealed that the mean lumen diameter, lumen area and calcium arc did not significantly differ between CTCA and IVUS within the smallest lumens (1(st) tertile of mean lumen diameter at 2.1 mm, and 1(st) tertile of lumen area at 3.7 mm(2)) and lowest calcium arc (mean of 40°). Although, on average, CTCA underestimates lumen diameter and area as well as calcium arc within calcified lesions, the differences are not significant within the smallest vessels and calcium arcs. The low diagnostic accuracy of CTCA within calcified lesions may be attributed to high variance and not to systematic error of measurements.
Mangold, Stefanie; Gatidis, Sergios; Luz, Oliver; König, Benjamin; Schabel, Christoph; Bongers, Malte N; Flohr, Thomas G; Claussen, Claus D; Thomas, Christoph
2014-12-01
The objective of this study was to retrospectively determine the potential of virtual monoenergetic (ME) reconstructions for a reduction of metal artifacts using a new-generation single-source computed tomographic (CT) scanner. The ethics committee of our institution approved this retrospective study with a waiver of the need for informed consent. A total of 50 consecutive patients (29 men and 21 women; mean [SD] age, 51.3 [16.7] years) with metal implants after osteosynthetic fracture treatment who had been examined using a single-source CT scanner (SOMATOM Definition Edge; Siemens Healthcare, Forchheim, Germany; consecutive dual-energy mode with 140 kV/80 kV) were selected. Using commercially available postprocessing software (syngo Dual Energy; Siemens AG), virtual ME data sets with extrapolated energy of 130 keV were generated (medium smooth convolution kernel D30) and compared with standard polyenergetic images reconstructed with a B30 (medium smooth) and a B70 (sharp) kernel. For quantification of the beam hardening artifacts, CT values were measured on circular lines surrounding bone and the osteosynthetic device, and frequency analyses of these values were performed using discrete Fourier transform. A high proportion of low frequencies to the spectrum indicates a high level of metal artifacts. The measurements in all data sets were compared using the Wilcoxon signed rank test. The virtual ME images with extrapolated energy of 130 keV showed significantly lower contribution of low frequencies after the Fourier transform compared with any polyenergetic data set reconstructed with D30, B70, and B30 kernels (P < 0.001). Sequential single-source dual-energy CT allows an efficient reduction of metal artifacts using high-energy ME extrapolation after osteosynthetic fracture treatment.
Report on in-situ studies of flash sintering of uranium dioxide
DOE Office of Scientific and Technical Information (OSTI.GOV)
Raftery, Alicia Marie
Flash sintering is a novel type of field assisted sintering that uses an electric field and current to provide densification of materials on very short time scales. The potential for field assisted sintering techniques to be used in producing nuclear fuel is gaining recognition due to the potential economic benefits and improvements in material properties. The flash sintering behavior has so far been linked to applied and material parameters, but the underlying mechanisms active during flash sintering have yet to be identified. This report summarizes the efforts to investigate flash sintering of uranium dioxide using dilatometer studies at Los Alamosmore » National Laboratory and two separate sets of in-situ studies at Brookhaven National Laboratory’s NSLS-II XPD-1 beamline. The purpose of the dilatometer studies was to understand individual parameter (applied and material) effects on the flash behavior and the purpose of the in-situ studies was to better understand the mechanisms active during flash sintering. As far as applied parameters, it was found that stoichiometry, or oxygen-to-metal ratio, has a significant effect on the flash behavior (time to flash and speed of flash). Composite systems were found to have degraded sintering behavior relative to pure UO 2. The critical field studies are complete for UO 2.00 and will be analyzed against an existing model for comparison. The in-situ studies showed that the strength of the field and current are directly related to the sample temperature, with temperature-driven phase changes occurring at high values. The existence of an ‘incubation time’ has been questioned, due to a continuous change in lattice parameter values from the moment that the field is applied. Some results from the in-situ experiments, which should provide evidence regarding ion migration, are still being analyzed. Some preliminary conclusions can be made from these results with regard to using field assisted sintering to fabricate nuclear fuel. First, the pure UO 2-based system shows promising behavior with flash sintering, but composite systems are likely to show better sintering behavior with spark plasma sintering. Efforts to develop these methods should therefore be tailored towards the likelihood of success. Additionally, modeling is a rapidly developing aspect of current flash sintering research and should be used in parallel with experiments. Ultimately, ongoing flash sintering studies on various materials, like those summarized in this report, are rapidly contributing to the feasibility of controlling this method for use in the future.« less
2011-01-01
Background Hot flashes are a highly prevalent problem associated with menopause and breast cancer treatments. The recent findings from the Women's Health Initiative have important implications for the significance of a non-hormonal, mind-body intervention for hot flashes in breast cancer survivors. Women who take hormone therapy long-term may have a 1.2 to 2.0 fold increased risk of developing breast cancer. In addition, it is now known that hormone therapy with estrogen and progestin is associated with increased risk of cardiovascular disease and stroke. Currently there are limited options to hormone replacement therapy as non-hormonal pharmacological agents are associated with only modest activity and many adverse side effects. Because of this there is a need for more alternative, non-hormonal therapies. Hypnosis is a mind-body intervention that has been shown to reduce self-reported hot flashes by up to 68% among breast cancer survivors, however, the use of hypnosis for hot flashes among post-menopausal women has not been adequately explored and the efficacy of hypnosis in reducing physiologically measured hot flashes has not yet been determined. Methods/design A sample of 180 post-menopausal women will be randomly assigned to either a 5-session Hypnosis Intervention or 5-session structured-attention control with 12 week follow-up. The present study will compare hypnosis to a structured-attention control in reducing hot flashes (perceived and physiologically monitored) in post-menopausal women in a randomized clinical trial. Outcomes will be hot flashes (self-report daily diaries; physiological monitoring; Hot Flash Related Daily Interference Scale), anxiety (State-Trait Anxiety Inventory; Hospital Anxiety and Depression Scale (HADS); anxiety visual analog scale (VAS rating); depression (Center for Epidemiologic Studies Depression Scale), sexual functioning (Sexual Activity Questionnaire), sleep quality (Pittsburgh Sleep Quality Index) and cortisol. Discussion This study will be the first full scale test of hypnosis for hot flashes; one of the first studies to examine both perceived impact and physiologically measured impact of a mind-body intervention for hot flashes using state-of-the-art 24 hour ambulatory physiological monitoring; the first study to examine the effect of hypnosis for hot flashes on cortisol; and the first investigation of the role of cognitive expectancies in treatment of hot flashes in comparison to a Structured-Attention Control. Trial Registration This clinical trial has been registered with ClinicalTrials.gov, a service of the U.S. National Institutes of Health, ClinicalTrials.gov Identifier: NCT01293695. PMID:21989181
Tuomikoski, Pauliina; Mikkola, Tomi S; Hämäläinen, Esa; Tikkanen, Matti J; Turpeinen, Ursula; Ylikorkala, Olavi
2010-01-01
Menopausal hot flashes may affect vascular function and perhaps explain conflicting data on cardiovascular disease (CVD) between observational and randomized hormone therapy (HT) studies. We prospectively assessed hot flash status in recently postmenopausal women and related it to a number of biochemical vascular surrogate markers for CVD. Healthy, nonsmoking women (n = 150) exhibiting a broad range (no, mild, moderate, severe) of hot flashes and an onset of menopause within the previous 0.5 to 3 years were studied with laboratory tests for lipids, lipoproteins, apolipoproteins, high-sensitivity C-reactive protein, and sex hormone-binding globulin. Apart from marked differences in hot flashes, the groups showed comparable levels of estrone, estradiol, or free estradiol index. The levels of total cholesterol (3.7-9.1 mmol/L) were similar between the groups (P = 0.744), and hypercholesterolemia (>6.5 mmol/L) was encountered equally often (P = 0.699). No difference was seen in high-, low-, or very low-density lipoproteins, triglycerides, apolipoprotein A-1, apolipoprotein B (or their ratio), or lipoprotein(a) between the groups. The levels of sex hormone-binding globulin and high-sensitivity C-reactive protein correlated negatively with each other (r = -0.204; P = 0.013) but showed no dependence on hot flashes (P = 0.531 and P = 0.215, respectively). No baseline difference in lipid or nonlipid CVD risk factors was observed between women with hot flashes (potential HT users) and women with no or mild hot flashes (potential HT nonusers). This may imply that hot flash status per se cannot explain the difference between observational and randomized trials.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hillman, Y.; Prialnik, D.; Kovetz, A.
Can a white dwarf (WD), accreting hydrogen-rich matter from a non-degenerate companion star, ever exceed the Chandrasekhar mass and explode as a SN Ia? We explore the range of accretion rates that allow a WD to secularly grow in mass, and derive limits on the accretion rate and on the initial mass that will allow it to reach 1.4M{sub ⊙}—the Chandrasekhar mass. We follow the evolution through a long series of hydrogen flashes, during which a thick helium shell accumulates. This determines the effective helium mass accretion rate for long-term, self-consistent evolutionary runs with helium flashes. We find that netmore » mass accumulation always occurs despite helium flashes. Although the amount of mass lost during the first few helium shell flashes is a significant fraction of that accumulated prior to the flash, that fraction decreases with repeated helium shell flashes. Eventually no mass is ejected at all during subsequent flashes. This unexpected result occurs because of continual heating of the WD interior by the helium shell flashes near its surface. The effect of heating is to lower the electron degeneracy throughout the WD, especially in the outer layers. This key result yields helium burning that is quasi-steady state, instead of explosive. We thus find a remarkably large parameter space within which long-term, self-consistent simulations show that a WD can grow in mass and reach the Chandrasekhar limit, despite its helium flashes.« less
NASA Astrophysics Data System (ADS)
Saber, M.; Sefelnasr, A.; Yilmaz, K. K.
2015-12-01
Flash flood is a natural hydrological phenomenon which affects many regions of the world. The behavior and effect of this phenomenon is different from one region to the other regions depending on several issues such as climatology and hydrological and topographical conditions at the target regions. Wadi assiut, Egypt as arid environment, and Gumara catchment, Lake Tana, Ethiopia, as humid conditions have been selected for application. The main target of this work is to simulate flash floods at both catchments considering the difference between them on the flash flood behaviors based on the variability of both of them. In order to simulate the flash floods, remote sensing data and a physical-based distributed hydrological model, Hydro-BEAM-WaS (Hydrological River Basin Environmental Assessment Model incorporating Wadi System) have been integrated used in this work. Based on the simulation results of flash floods in these regions, it was found that the time to reach the maximum peak is very short and consequently the warning time is very short as well. It was found that the flash floods starts from zero flow in arid environment, but on the contrary in humid arid, it starts from Base flow which is changeable based on the simulated events. Distribution maps of flash floods showing the vulnerable regions of these selected areas have been developed. Consequently, some mitigation strategies relying on this study have been introduced. The proposed methodology can be applied effectively for flash flood forecasting at different climate regions, however the paucity of observational data.
NASA Astrophysics Data System (ADS)
Caicedo, J. A.; Uman, M. A.; Pilkey, J. T.
2018-01-01
We present the first lightning evolution studies, via the Lightning Mapping Array (LMA) and radar, performed in North Central Florida. Parts of three winter/spring frontal storms (cold season) and two complete summer (warm season) multicell storms are studied. Storm parameters measured are as follows: total number of flashes, flash-type classification, first flashes, flash initiation altitude, flash initiation power, flash rate (flashes per minute), charge structure, altitude and temperature ranges of the inferred charge regions, atmospheric isotherm altitude, radar base reflectivity (dBZ), and radar echo tops (EET). Several differences were found between summer multicell and winter/spring frontal storms in North Central Florida: (1) in winter/spring storms, the range of altitudes that all charge regions occupy is up to 1 km lower in altitude than in summer storms, as are the 0°C, -10°C, and -20°C isotherms; (2) lightning activity in summer storms is highly correlated with changes in radar signatures, in particular, echo tops; and (3) the LMA average initiation power of all flash types in winter/frontal storms is about an order of magnitude larger than that for summer storms. In relation to storms in other geographical locations, North Central Florida seasonal storms were found to have similarities in most parameters studied with a few differences, examples in Florida being (1) colder initiation altitudes for intracloud flashes, (2) charge regions occupying larger ranges of atmospheric temperatures, and (3) winter/spring frontal storms not having much lightning activity in the stratiform region.
Accessibility - This is a link to an external javascript file that searchs for a flash browser plug-in and what version of the browser is being used. The javascript is functional ToxMystery uses Adobe Flash Player. If you cannot install Flash Player, please use ...
Dosani, M; Morris, W J; Tyldesley, S; Pickles, T
2017-10-01
This study describes the proportion of men who experienced hot flashes (flashes), and the testosterone level at onset, peak frequency and cessation of flashes after 12 months of androgen deprivation therapy (ADT) in men undergoing curative-intent external beam radiation therapy (± brachytherapy boost). We also aimed to characterise testosterone recovery in this population. This was a pre-specified secondary analysis of the ASCENDE-RT clinical trial. Three hundred and ninety-eight men were randomised. All received 12 months of ADT. The presence and frequency of flashes were patient reported. Cessation of flashes was defined as the first date a patient reported resolution of this symptom. Testosterone recovery was defined as any single serum testosterone above the threshold of 5, 7.5 or 10 nmol/l. The median age and follow-up were 68 years and 6.1 years. Flashes were reported in 93% of men. Flashes began and reached peak frequency at a median time of 4.0 months from the first luteinizing hormone-releasing hormone injection when testosterone levels had fallen to castrate. The median time to cessation of flashes was 7.6 months after the cessation of ADT (last injection + 3 months), when the median testosterone had risen to 5.7 nmol/l. A resolution of flashes was reported in 99% of patients. Baseline testosterone was available in 338 patients (85%). The median baseline testosterone was 13.2 nmol/l. The median (95% confidence interval) time of testosterone recovery to thresholds of 5 nmol/l, 7.5 nmol/l and 10 nmol/l were 9 (9-10) months, 13 (10-15) months and 18 (17-19) months from the cessation of ADT. At the time of censor, 96, 94 and 91% of patients had recovered testosterone to thresholds of 5, 7.5 and 10 nmol/l. Flashes occur at castrate levels of testosterone, with cessation of hot flashes antedating full recovery of testosterone in most patients. Rates of testosterone recovery after 12 months of ADT exceed 90%, although it can be delayed. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
An 11-Year Climatology of Storms in Which Most Cloud-to-Ground Flashes Lower Positive Charge
NASA Astrophysics Data System (ADS)
MacGorman, D. R.; Eddy, A.; Williams, E. R.; Calhoun, K. M.
2017-12-01
Previous studies have shown that storms which produce frequent cloud-to-ground (CG) lightning dominated by flashes lowering positive charge to ground (+CG flashes) tend to have a so called "inverted" vertical distribution of charge. Such storms have implications for our understanding of electrification processes. We have analyzed eleven years of National Lightning Detection Network data to count +CG and -CG flashes having peak currents ≥15 kA in grid cells with dimensions of 15 km x 15 km x 15 min, with overlapping grid boxes every 5 km along both x and y over the contiguous United States and grids every 5 min in time. These dimensions were chosen because 15 km corresponds roughly to the horizontal size of typical storm cells and 15 min is roughly half the typical duration of a cell. To focus on storms dominated by +CG flashes, we identified all grid cells satisfying one of four sets of thresholds: cells in which +CG flashes for 15 min constitute ≥80%, 90%, or 100% of ≥10 CG flashes or 100% of ≥20 CG flashes. These percentages are larger than those used in most previous studies of +CG flashes. Our primary goal is to investigate the environmental and storm characteristics conducive to +CG flashes and "inverted-polarity" charge distributions, but here we concentrate on the interannual and seasonal distributions of storms satisfying the above thresholds and examine also their relationship to severe weather. As in previous climatological studies of geographic variations in the +CG fraction of total CG flashes, most storms satisfying our thresholds were in a swath stretching from far eastern Colorado and western Kansas roughly northward through Nebraska, the Dakotas, and Minnesota. This region overlaps much of the region in which radar inferred that hail larger than 2.9 cm in diameter most often occurs, but is shifted westward and northward from maxima of observer reports of large-hail occurrence. Although the relationship with radar-inferred large-hail frequency suggests a common dependence on some storm characteristics, storms satisfying our thresholds for +CG flashes also occurred, although less frequently, in regions in which few storms were inferred to have produced large hail, such as east of mountain ranges in northwestern states, so relationships with severe weather will need to be examined on a storm-by-storm basis.
Belyaeva, N E; Schmitt, F-J; Paschenko, V Z; Riznichenko, G Yu; Rubin, A B; Renger, G
2011-02-01
Our recently presented PS II model (Belyaeva et al., 2008) was improved in order to permit a consistent simulation of Single Flash Induced Transient Fluorescence Yield (SFITFY) traces that were earlier measured by Steffen et al. (2005) on whole leaves of Arabidopsis (A.) thaliana at four different energies of the actinic flash. As the essential modification, the shape of the actinic flash was explicitly taken into account assuming that an exponentially decaying rate simulates the time dependent excitation of PS II by the 10 ns actinic flash. The maximum amplitude of this excitation exceeds that of the measuring light by 9 orders of magnitude. A very good fit of the SFITFY data was achieved in the time domain from 100 ns to 10s for all actinic flash energies (the maximum energy of 7.5 × 10¹⁶ photons/(cm²flash) is set to 100%, the relative energies of weaker actinic flashes were of ∼8%, 4%, ∼1%). Our model allows the calculation and visualization of the transient PS II redox state populations ranging from the dark adapted state, via excitation energy and electron transfer steps induced by pulse excitation, followed by final relaxation into the stationary state eventually attained under the measuring light. It turned out that the rate constants of electron transfer steps are invariant to intensity of the actinic laser flash. In marked contrast, an increase of the actinic flash energy by more than two orders of magnitude from 5.4×10¹⁴ photons/(cm²flash) to 7.5×10¹⁶ photons/(cm²flash), leads to an increase of the extent of fluorescence quenching due to carotenoid triplet (³Car) formation by a factor of 14 and of the recombination reaction between reduced primary pheophytin (Phe(-)) and P680(+) by a factor of 3 while the heat dissipation in the antenna complex remains virtually constant. The modified PS II model offers new opportunities to compare electron transfer and dissipative parameters for different species (e.g. for the green algae and the higher plant) under varying illumination conditions. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
A global flash flood forecasting system
NASA Astrophysics Data System (ADS)
Baugh, Calum; Pappenberger, Florian; Wetterhall, Fredrik; Hewson, Tim; Zsoter, Ervin
2016-04-01
The sudden and devastating nature of flash flood events means it is imperative to provide early warnings such as those derived from Numerical Weather Prediction (NWP) forecasts. Currently such systems exist on basin, national and continental scales in Europe, North America and Australia but rely on high resolution NWP forecasts or rainfall-radar nowcasting, neither of which have global coverage. To produce global flash flood forecasts this work investigates the possibility of using forecasts from a global NWP system. In particular we: (i) discuss how global NWP can be used for flash flood forecasting and discuss strengths and weaknesses; (ii) demonstrate how a robust evaluation can be performed given the rarity of the event; (iii) highlight the challenges and opportunities in communicating flash flood uncertainty to decision makers; and (iv) explore future developments which would significantly improve global flash flood forecasting. The proposed forecast system uses ensemble surface runoff forecasts from the ECMWF H-TESSEL land surface scheme. A flash flood index is generated using the ERIC (Enhanced Runoff Index based on Climatology) methodology [Raynaud et al., 2014]. This global methodology is applied to a series of flash floods across southern Europe. Results from the system are compared against warnings produced using the higher resolution COSMO-LEPS limited area model. The global system is evaluated by comparing forecasted warning locations against a flash flood database of media reports created in partnership with floodlist.com. To deal with the lack of objectivity in media reports we carefully assess the suitability of different skill scores and apply spatial uncertainty thresholds to the observations. To communicate the uncertainties of the flash flood system output we experiment with a dynamic region-growing algorithm. This automatically clusters regions of similar return period exceedence probabilities, thus presenting the at-risk areas at a spatial resolution appropriate to the NWP system. We then demonstrate how these warning areas could eventually complement existing global systems such as the Global Flood Awareness System (GloFAS), to give warnings of flash floods. This work demonstrates the possibility of creating a global flash flood forecasting system based on forecasts from existing global NWP systems. Future developments, in post-processing for example, will need to address an under-prediction bias, for extreme point rainfall, that is innate to current-generation global models.
NASA Astrophysics Data System (ADS)
Portugués-Mollá, I.; Bonache-Felici, X.; Mateu-Bellés, J. F.; Marco-Segura, J. B.
2016-10-01
Flash floods are recurrent events around the Mediterranean region. Extreme episodes activate hydro-geomorphic high-intensity processes with low frequency. In urban environments, the complexity becomes higher due to the existence of very quick-response runoff. However, immediate recovery works remove the urban marks. After a short time both the significance and magnitude of the hydro-geomorphic event become completely unrecognizable. Nevertheless, these episodes generate extensive documentation which is testimony of the processes in almost real time. It is necessary to exploit this source typology in order to draw flood sketches when events far in time may lack a sufficiently rich database. This is particularly the case for the Valencia flash flood (October 1957), located in the lower Turia River basin (Eastern Spain). It left numerous pieces of hydro-geomorphic evidence, but its tracks were covered a short while after the flood. In any case, it remains part of a non-systematic legacy that has not yet been exploited, consisting of immediate aerial and oblique high resolution photography, pictures at street level, water marks and administrative records. Paradoxically, despite being considered a milestone in metropolitan territorial planning (the river was definitely diverted), an accurate reconstruction of the hydraulic behaviour was required from an integrated point of view. To this aim, the development of a GIS-Based Model enabled the utilisation of the above-mentioned materials. This non-conventional information was treated jointly from a new perspective. It provided database support through a vast amount of organised, structured and georeferenced information about the 1957 event. In a second stage, the GBM made it possible to characterise the Turia urban reach and interpret both the hydro-geomorphic (trenches along barrier beaches, erosion, deposition, etc.) and hydraulic (urban streams along the streets, flow directions, flood extent, levees breaks, overflows and inflows, etc.) processes mainly through photo-interpretation.
Design and realization of flash translation layer in tiny embedded system
NASA Astrophysics Data System (ADS)
Ren, Xiaoping; Sui, Chaoya; Luo, Zhenghua; Cao, Wenji
2018-05-01
We design a solution of tiny embedded device NAND Flash storage system on the basis of deeply studying the characteristics of widely used NAND Flash in the embedded devices in order to adapt to the development of intelligent interconnection trend and solve the storage problem of large data volume in tiny embedded system. The hierarchical structure and function purposes of the system are introduced. The design and realization of address mapping, error correction, bad block management, wear balance, garbage collection and other algorithms in flash memory transformation layer are described in details. NAND Flash drive and management are realized on STM32 micro-controller, thereby verifying design effectiveness and feasibility.
Assessing Semantic Knowledge Using Computer-Based and Paper-Based Media
1992-01-01
capitalized upon in this research. Computer-Based Assessment A computer-based game or test, FlashCards (Liggett & Federico, 1986), was adopt- ed and adapted...alterative forms did not have to be specifically or previously programmed as such. FlashCards is analogous to using real flash cards. That is, a...reflects their degree of confidence in their answer. Also, for each answer the student’s response latency is recorded and displayed. FlashCards quizzed
Sternal skin conductance: a reasonable surrogate for hot flash measurement?
Pachman, Deirdre R; Loprinzi, Charles L; Novotny, Paul J; Satele, Daniel V; Linquist, Breanna M; Wolf, Sherry; Barton, Debra L
2013-11-01
This study aims to examine the accuracy of a new sternal skin conductance (SSC) device in measuring hot flashes and to assess the acceptability of the device by women. Three small descriptive pilot studies were performed using two sequential prototypes of the SSC device developed by an engineering device company in the Midwest. The devices were worn either in a monitored setting for 24 hours or in an ambulatory setting for 5 weeks. During the study period, women recorded hot flashes in a prospective hot flash diary and answered questions about the acceptability of wearing the SSC device. The first prototype was not able to collect any analyzable skin conductance data owing to various malfunction issues, including poor conductance and battery failure. However, 16 women wore the device for 5 weeks and reported that wearing the device was acceptable, although 31% stated that it interfered with daily activities. Hot flash data from the second prototype revealed a 24% concordance rate between self-reported and device-recorded hot flashes. Findings from these studies support discordance between device-recorded and self-reported hot flashes. In addition, the studies reveal further limitations of SSC monitoring, including difficulties with data collection and lack of consistency in interpretation. Based on these results and other recent trials identifying issues with SSC methodology, it is time to find a better physiologic surrogate measure for hot flashes.
Hot flashes are not predictive for serum concentrations of tamoxifen and its metabolites
2013-01-01
Background Tamoxifen has dramatically reduced the recurrence and mortality rate of estrogen receptor positive breast cancer. However, the efficacy of tamoxifen varies between individuals and 40% of patients will have a recurrence despite adjuvant tamoxifen treatment. Factors that predict tamoxifen efficacy would be helpful for optimizing treatment. Serum concentrations of the active metabolite, endoxifen, may be positively related to treatment outcome. In addition, hot flashes are suggested to be positively associated with tamoxifen treatment outcome. Methods We investigated in a series of 109 patients whether the frequency and severity of hot flashes were related to concentrations of tamoxifen and its metabolites. A serum sample of all patients was analyzed for the concentration of tamoxifen, N-desmethyltamoxifen, endoxifen and 4-hydroxytamoxifen, as well as for estradiol concentrations and several single nucleotide polymorphisms in CYP2D6. Additionally, these patients completed a questionnaire concerning biometric data and treatment side effects. Results We found no evidence supporting an association between concentrations of tamoxifen or metabolites and either the frequency or severity of hot flashes in the covariate unadjusted analyses. However, including interactions with menopausal status and pre-treatment hot flash (PTHF) history indicated that post-menopausal women with PTHF experienced an increasing frequency of hot flashes with increasing serum concentrations of tamoxifen and its metabolites. This finding was not altered when adjusting for potential confounding factors (duration of tamoxifen treatment, CYP2D6 phenotype, estradiol serum concentration, age and body mass index). In addition we observed a positive association between body mass index and both hot flash frequency (p = 0.04) and severity (p < 0.0001). We also observed that patients with lower estradiol levels reported more severe hot flashes (p = 0.02). Conclusions No univariate associations were observed between concentrations of active tamoxifen metabolites and either the frequency or severity of hot flashes during treatment. However, the frequency of hot flashes may be exacerbated by higher serum concentrations of tamoxifen and its metabolites in post-menopausal women with a history of hot flashes prior to tamoxifen treatment. PMID:24373320
Impact Flash Monitoring Facility on the Deep Space Gateway
NASA Astrophysics Data System (ADS)
Needham, D. H.; Moser, D. E.; Suggs, R. M.; Cooke, W. J.; Kring, D. A.; Neal, C. R.; Fassett, C. I.
2018-02-01
Cameras mounted to the Deep Space Gateway exterior will detect flashes caused by impacts on the lunar surface. Observed flashes will help constrain the current lunar impact flux and assess hazards faced by crews living and working in cislunar space.
Development of a precipitation-area curve for warning criteria of short-duration flash flood
NASA Astrophysics Data System (ADS)
Bae, Deg-Hyo; Lee, Moon-Hwan; Moon, Sung-Keun
2018-01-01
This paper presents quantitative criteria for flash flood warning that can be used to rapidly assess flash flood occurrence based on only rainfall estimates. This study was conducted for 200 small mountainous sub-catchments of the Han River basin in South Korea because South Korea has recently suffered many flash flood events. The quantitative criteria are calculated based on flash flood guidance (FFG), which is defined as the depth of rainfall of a given duration required to cause frequent flooding (1-2-year return period) at the outlet of a small stream basin and is estimated using threshold runoff (TR) and antecedent soil moisture conditions in all sub-basins. The soil moisture conditions were estimated during the flooding season, i.e., July, August and September, over 7 years (2002-2009) using the Sejong University Rainfall Runoff (SURR) model. A ROC (receiver operating characteristic) analysis was used to obtain optimum rainfall values and a generalized precipitation-area (P-A) curve was developed for flash flood warning thresholds. The threshold function was derived as a P-A curve because the precipitation threshold with a short duration is more closely related to basin area than any other variables. For a brief description of the P-A curve, generalized thresholds for flash flood warnings can be suggested for rainfall rates of 42, 32 and 20 mm h-1 in sub-basins with areas of 22-40, 40-100 and > 100 km2, respectively. The proposed P-A curve was validated based on observed flash flood events in different sub-basins. Flash flood occurrences were captured for 9 out of 12 events. This result can be used instead of FFG to identify brief flash flood (less than 1 h), and it can provide warning information to decision-makers or citizens that is relatively simple, clear and immediate.
Age-related change in fast adaptation mechanisms measured with the scotopic full-field ERG.
Tillman, Megan A; Panorgias, Athanasios; Werner, John S
2016-06-01
To quantify the response dynamics of fast adaptation mechanisms of the scotopic ERG in younger and older adults using full-field m-sequence flash stimulation. Scotopic ERGs were measured for a series of flashes separated by 65 ms over a range of 260 ms in 16 younger (20-26, 22.2 ± 2.1; range mean ±1 SD) and 16 older (65-85, 71.2 ± 7) observers without retinal pathology. A short-wavelength (λ peak = 442 nm) LED was used for scotopic stimulation, and the flashes ranged from 0.0001 to 0.01 cd s m(-2). The complete binary kernel series was derived from the responses to the m-sequence flash stimulation, and the first- and second-order kernel responses were analyzed. The first-order kernel represented the response to a single, isolated flash, while the second-order kernels reflected the adapted flash responses that followed a single flash by one or more base intervals. B-wave amplitudes of the adapted flash responses were measured and plotted as a function of interstimulus interval to describe the recovery of the scotopic ERG. A linear function was fitted to the linear portion of the recovery curve, and the slope of the line was used to estimate the rate of fast adaptation recovery. The amplitudes of the isolated flash responses and rates of scotopic fast adaptation recovery were compared between the younger and older participants using a two-way ANOVA. The isolated flash responses and rates of recovery were found to be significantly lower in the older adults. However, there was no difference between the two age groups in response amplitude or recovery rate after correcting for age-related changes in the density of the ocular media. These results demonstrated that the rate of scotopic fast adaptation recovery of normal younger and older adults is similar when stimuli are equated for retinal illuminance.
Nonlinear dynamic model of a gear-rotor-bearing system considering the flash temperature
NASA Astrophysics Data System (ADS)
Gou, Xiangfeng; Zhu, Lingyun; Qi, Changjun
2017-12-01
The instantaneous flash temperature is an important factor for gears in service. To investigate the effect of the flash temperature of a tooth surface on the dynamics of the spur gear system, a modified nonlinear dynamic model of a gear-rotor-bearing system is established. The factors such as the contact temperature of the tooth surface, time-varying stiffness, tooth surface friction, backlash, the comprehensive transmission error and so on are considered. The flash temperature of a tooth surface of pinion and gear is formulated according to Blok's flash temperature theory. The mathematical expression of the contact temperature of the tooth surface varied with time is derived and the tooth profile deformation caused by the change of the flash temperature of the tooth surface is calculated. The expression of the mesh stiffness varied with the flash temperature of the tooth surface is derived based on Hertz contact theory. The temperature stiffness is proposed and added to the nonlinear dynamic model of the system. The influence of load on the flash temperature of the tooth surface is analyzed in the parameters plane. The variation of the flash temperature of the tooth surface is studied. The numerical results indicate that the calculated method of the flash temperature of the gear tooth surface is effective and it can reflect the rules for the change of gear meshing temperature and sliding of the gear tooth surface. The effects of frequency, backlash, bearing clearance, comprehensive transmission error and time-varying stiffness on the nonlinear dynamics of the system are analyzed according to the bifurcation diagrams, Top Lyapunov Exponent (TLE) spectrums, phase portraits and Poincaré maps. Some nonlinear phenomena such as periodic bifurcation, grazing bifurcation, quasi-periodic bifurcation, chaos and its routes to chaos are investigated and the critical parameters are identified. The results provide an understanding of the system and serve as a useful reference in designing such systems.
Levetiracetam for the treatment of hot flashes: a phase II study.
Thompson, Susan; Bardia, Aditya; Tan, Angelina; Barton, Debra L; Kottschade, Lisa; Sloan, Jeff A; Christensen, Brad; Smith, DeAnne; Loprinzi, Charles L
2008-01-01
The objectives of this pilot trial were to assess the potential efficacy and safety of levetiracetam for the treatment of hot flashes, a major cause of morbidity among breast cancer survivors. Women, aged 18 years or more, with a history of breast cancer or those who wished to avoid estrogen because of a perceived increased risk of breast cancer, who were experiencing bothersome hot flashes (more than or equal to 14 times per week, for more than or equal to 1 month before study entry), were included. During the baseline week, general demographic characteristics, hot flash information, and quality of life data were obtained. At the beginning of week 2, patients were started on levetiracetam for a total of 4 weeks. Information about hot flashes, quality of life, and toxicity were collected during these 4 weeks and compared with the baseline week. After treatment with levetiracetam for 4 weeks (N = 19), mean hot flash scores (frequency times mean severity) were reduced by 57%, and mean hot flash frequencies were reduced by 53%, compared to the baseline week; both these reductions were greater than what would be expected with a placebo (20-25% reduction). There were significant improvements in abnormal sweating (p = 0.004), hot flash distress (p = 0.0002), and satisfaction of hot flash control (p = 0.0001), when comparing data from the fourth week of treatment to the baseline week. Twenty-nine percent of the subjects did not complete the study because of treatment-related adverse events, with the most frequently reported side effects being somnolence, fatigue, and dizziness, usually with mild to moderate intensity. The results of this pilot trial suggest that levetiracetam might be an effective therapy for the treatment of hot flashes. Further data are needed to test this hypothesis, evaluating the efficacy and toxicity of this agent.
Parietal disruption alters audiovisual binding in the sound-induced flash illusion.
Kamke, Marc R; Vieth, Harrison E; Cottrell, David; Mattingley, Jason B
2012-09-01
Selective attention and multisensory integration are fundamental to perception, but little is known about whether, or under what circumstances, these processes interact to shape conscious awareness. Here, we used transcranial magnetic stimulation (TMS) to investigate the causal role of attention-related brain networks in multisensory integration between visual and auditory stimuli in the sound-induced flash illusion. The flash illusion is a widely studied multisensory phenomenon in which a single flash of light is falsely perceived as multiple flashes in the presence of irrelevant sounds. We investigated the hypothesis that extrastriate regions involved in selective attention, specifically within the right parietal cortex, exert an influence on the multisensory integrative processes that cause the flash illusion. We found that disruption of the right angular gyrus, but not of the adjacent supramarginal gyrus or of a sensory control site, enhanced participants' veridical perception of the multisensory events, thereby reducing their susceptibility to the illusion. Our findings suggest that the same parietal networks that normally act to enhance perception of attended events also play a role in the binding of auditory and visual stimuli in the sound-induced flash illusion. Copyright © 2012 Elsevier Inc. All rights reserved.
Some Improvements in Utilization of Flash Memory Devices
NASA Technical Reports Server (NTRS)
Gender, Thomas K.; Chow, James; Ott, William E.
2009-01-01
Two developments improve the utilization of flash memory devices in the face of the following limitations: (1) a flash write element (page) differs in size from a flash erase element (block), (2) a block must be erased before its is rewritten, (3) lifetime of a flash memory is typically limited to about 1,000,000 erases, (4) as many as 2 percent of the blocks of a given device may fail before the expected end of its life, and (5) to ensure reliability of reading and writing, power must not be interrupted during minimum specified reading and writing times. The first development comprises interrelated software components that regulate reading, writing, and erasure operations to minimize migration of data and unevenness in wear; perform erasures during idle times; quickly make erased blocks available for writing; detect and report failed blocks; maintain the overall state of a flash memory to satisfy real-time performance requirements; and detect and initialize a new flash memory device. The second development is a combination of hardware and software that senses the failure of a main power supply and draws power from a capacitive storage circuit designed to hold enough energy to sustain operation until reading or writing is completed.
NASA Technical Reports Server (NTRS)
Moser, D. E.
2017-01-01
Most meteoroids are broken up by Earth's atmosphere before they reach the ground. The Moon, however, has little-to-no atmosphere to prevent meteoroids from impacting the lunar surface. Upon impact they excavate a crater and generate a plume of debris. A flash of light at the moment of impact can also be seen. Meteoroids striking the Moon create an impact flash observable by telescopes here on Earth. NASA observers use telescopes at the Automated Lunar and Meteor Observatory (ALaMO) to routinely monitor the Moon for impact flashes each month when the lunar phase is right. Flashes recorded by two telescope simultaneously rule out false signals from cosmic rays and satellites. Over 400 impact flashes have been observed by NASA since 2005. This map shows the location of each flash. No observations are made near the poles or center line. On average, one impact is observed every two hours. The brightest and longest-lasting impact flash was observed in Mare Imbrium on March 17, 2013. The imaging satellite Lunar Reconnaissance Orbiter, in orbit around the Moon, discovered the fresh crater created by this impact. The crater is 60 across and was caused by a meteoroid 9 inches in diameter likely traveling at a speed of 57,000 mph!
Current alcohol use is associated with a reduced risk of hot flashes in midlife women.
Schilling, Chrissy; Gallicchio, Lisa; Miller, Susan R; Babus, Janice K; Lewis, Lynn M; Zacur, Howard; Flaws, Jodi A
2005-01-01
To examine the relation between current alcohol use, estradiol, estrone, and testosterone levels, and hot flashes in midlife women using a case-control study design. Cases were midlife women (45-54 years) who reported ever experiencing hot flashes. Controls were midlife women (45-54 years) who reported never experiencing hot flashes. Each participant completed a questionnaire and provided a blood sample that was used to measure estradiol, estrone, and testosterone levels by enzyme-linked immunosorbent assay. The results indicate that current alcohol use (at least one day per month) was significantly associated with a reduced risk of hot flashes compared to non-use of alcohol, independent of age and smoking habits. The hot flashes experienced by current alcohol users were less severe and less frequent than those experienced by non-users of alcohol. Further, current alcohol users had similar levels of estradiol, estrone, and testosterone compared to non-users of alcohol. These data suggest that current alcohol use is associated with a reduced risk of any, severe, and frequent hot flashes in midlife women by a mechanism that may not include changes in sex steroid hormone levels.
Serum leptin levels, hormone levels, and hot flashes in midlife women.
Alexander, Carolyn; Cochran, Chrissy J; Gallicchio, Lisa; Miller, Susan R; Flaws, Jodi A; Zacur, Howard
2010-08-01
To examine the associations between serum leptin levels, sex steroid hormone levels, and hot flashes in normal weight and obese midlife women. Cross-sectional study. University clinic. 201 Caucasian, nonsmoking women aged 45 to 54 years with a body mass index of <25 kg/m2 or >or=30 kg/m2. Questionnaire, fasting blood samples. Serum leptin and sex steroid hormone levels. Correlation and regression models were performed to examine associations between leptin levels, hormone levels, and hot flashes. Leptin levels were associated with BMI, with "ever experiencing hot flashes" (questionnaire), with hot flashes within the last 30 days, and with duration of hot flashes (>1 year, P=.03). Leptin was positively correlated with testosterone, free testosterone index, and free estrogen index and inversely associated with levels of sex hormone-binding globulin. In women with a body mass index>or=30 kg/m2, leptin levels no longer correlated with testosterone levels. Serum leptin levels are associated with the occurrence and duration of hot flashes in midlife women; however, no correlation was found between leptin and serum estradiol. Copyright (c) 2010 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Montoya, Joseph; Kennerly, Stephen; Rede, Edward
2010-04-01
Utilization of Near-Infrared (NIR) spectral features in a muzzle flash will allow for small arms detection using low cost silicon (Si)-based imagers. Detection of a small arms muzzle flash in a particular wavelength region is dependent on the intensity of that emission, the efficiency of source emission transmission through the atmosphere, and the relative intensity of the background scene. The NIR muzzle flash signature exists in the relatively large Si spectral response wavelength region of 300 nm-1100 nm, which allows for use of commercial-off-the-shelf (COTS) Si-based detectors. The alkali metal origin of the NIR spectral features in the 7.62 × 39-mm round muzzle flash is discussed, and the basis for the spectral bandwidth is examined, using a calculated Voigt profile. This report will introduce a model of the 7.62 × 39-mm NIR muzzle flash signature based on predicted source characteristics. Atmospheric limitations based on NIR spectral regions are investigated in relation to the NIR muzzle flash signature. A simple signal-to-clutter ratio (SCR) metric is used to predict sensor performance based on a model of radiance for the source and solar background and pixel registered image subtraction.
Hot Flashes and Night Sweats (PDQ®)—Patient Version
Hot flashes and night sweats can be a side effect of cancer or its treatment and can occur in both women and men. Learn more about hot flashes and night sweats and ways to treat them in this expert-reviewed summary.
NASA Technical Reports Server (NTRS)
Koshak, William J.
2010-01-01
This viewgraph presentation describes the significant progress made in the flash-type discrimination algorithm development. The contents include: 1) Highlights of Progress for GLM-R3 Flash-Type discrimination Algorithm Development; 2) Maximum Group Area (MGA) Data; 3) Retrieval Errors from Simulations; and 4) Preliminary Global-scale Retrieval.
A Bright Lunar Impact Flash Linked to the Virginid Meteor Complex
NASA Technical Reports Server (NTRS)
Moser, D. E.; Suggs, R. M.; Suggs, R. J.
2015-01-01
On 17 March 2013 at 03:50:54 UTC, NASA detected a bright impact flash on the Moon caused by a meteoroid impacting the lunar surface. There was meteor activity in Earth's atmosphere the same night from the Virginid Meteor Complex. The impact crater associated with the impact flash was found and imaged by Lunar Reconnaissance Orbiter (LRO). Goal: Monitor the Moon for impact flashes produced by meteoroids striking the lunar surface. Determine meteoroid flux in the 10's gram to kilogram size range.
Laser head for simultaneous optical pumping of several dye lasers. [with single flash lamp
NASA Technical Reports Server (NTRS)
Mumola, P. B.; Mcalexander, B. T. (Inventor)
1975-01-01
The invention is a laser head for simultaneous pumping several dye lasers with a single flash lamp. The laser head includes primarily a multi-elliptical cylinder cavity with a single flash lamp placed along the common focal axis of the cavity and with capillary tube dye cells placed along each of the other focal axes of the cavity. The inside surface of the cavity is polished. Hence, the single flash lamp supplies the energy to the several dye cells.
2000-04-01
AD__________ Award Number: DAMD17-99-1-9438 TITLE: Is Homeopathy Effective for Hot Flashes and Other Estrogen-Withdrawal Symptoms in Breast Cancer...Mar 00) 4. TITLE AND SUBTITLE 5. FUNDING NUMBERS Is Homeopathy Effective for Hot Flashes and Other Estrogen- DAMD17-99-1-9438 Withdrawal Symptoms in...there is evidence that homeopathy is an effective treatment to improve the quality of life in breast cancer survivors who are experiencing hot flashes
Automated Studies of Continuing Current in Lightning Flashes
NASA Astrophysics Data System (ADS)
Martinez-Claros, Jose
Continuing current (CC) is a continuous luminosity in the lightning channel that lasts longer than 10 ms following a lightning return stroke to ground. Lightning flashes following CC are associated with direct damage to power lines and are thought to be responsible for causing lightning-induced forest fires. The development of an algorithm that automates continuing current detection by combining NLDN (National Lightning Detection Network) and LEFA (Langmuir Electric Field Array) datasets for CG flashes will be discussed. The algorithm was applied to thousands of cloud-to-ground (CG) flashes within 40 km of Langmuir Lab, New Mexico measured during the 2013 monsoon season. It counts the number of flashes in a single minute of data and the number of return strokes of an individual lightning flash; records the time and location of each return stroke; performs peak analysis on E-field data, and uses the slope of interstroke interval (ISI) E-field data fits to recognize whether continuing current (CC) exists within the interval. Following CC detection, duration and magnitude are measured. The longest observed C in 5588 flashes was 631 ms. The performance of the algorithm (vs. human judgement) was checked on 100 flashes. At best, the reported algorithm is "correct" 80% of the time, where correct means that multiple stations agree with each other and with a human on both the presence and duration of CC. Of the 100 flashes that were validated against human judgement, 62% were hybrid. Automated analysis detects the first but misses the second return stroke in many cases where the second return stroke is followed by long CC. This problem is also present in human interpretation of field change records.
Cloud-to-ground lightning activity in Colombia: A 14-year study using lightning location system data
NASA Astrophysics Data System (ADS)
Herrera, J.; Younes, C.; Porras, L.
2018-05-01
This paper presents the analysis of 14 years of cloud-to-ground lightning activity observation in Colombia using lightning location systems (LLS) data. The first Colombian LLS operated from 1997 to 2001. After a few years, this system was upgraded and a new LLS has been operating since 2007. Data obtained from these two systems was analyzed in order to obtain lightning parameters used in designing lightning protection systems. The flash detection efficiency was estimated using average peak current maps and some theoretical results previously published. Lightning flash multiplicity was evaluated using a stroke grouping algorithm resulting in average values of about 1.0 and 1.6 for positive and negative flashes respectively and for both LLS. The time variation of this parameter changes slightly for the years considered in this study. The first stroke peak current for negative and positive flashes shows median values close to 29 kA and 17 kA respectively for both networks showing a great dependence on the flash detection efficiency. The average percentage of negative and positive flashes shows a 74.04% and 25.95% of occurrence respectively. The daily variation shows a peak between 23 and 02 h. The monthly variation of this parameter exhibits a bimodal behavior typical of the regions located near The Equator. The lightning flash density was obtained dividing the study area in 3 × 3 km cells and resulting in maximum average values of 25 and 35 flashes km- 2 year- 1 for each network respectively. A comparison of these results with global lightning activity hotspots was performed showing good correlation. Besides, the lightning flash density variation with altitude shows an inverse relation between these two variables.
A conserved interaction that is essential for the biogenesis of histone locus bodies.
Yang, Xiao-cui; Sabath, Ivan; Kunduru, Lalitha; van Wijnen, Andre J; Marzluff, William F; Dominski, Zbigniew
2014-12-05
Nuclear protein, ataxia-telangiectasia locus (NPAT) and FLICE-associated huge protein (FLASH) are two major components of discrete nuclear structures called histone locus bodies (HLBs). NPAT is a key co-activator of histone gene transcription, whereas FLASH through its N-terminal region functions in 3' end processing of histone primary transcripts. The C-terminal region of FLASH contains a highly conserved domain that is also present at the end of Yin Yang 1-associated protein-related protein (YARP) and its Drosophila homologue, Mute, previously shown to localize to HLBs in Drosophila cells. Here, we show that the C-terminal domain of human FLASH and YARP interacts with the C-terminal region of NPAT and that this interaction is essential and sufficient to drive FLASH and YARP to HLBs in HeLa cells. Strikingly, only the last 16 amino acids of NPAT are sufficient for the interaction. We also show that the C-terminal domain of Mute interacts with a short region at the end of the Drosophila NPAT orthologue, multi sex combs (Mxc). Altogether, our data indicate that the conserved C-terminal domain shared by FLASH, YARP, and Mute recognizes the C-terminal sequence of NPAT orthologues, thus acting as a signal targeting proteins to HLBs. Finally, we demonstrate that the C-terminal domain of human FLASH can be directly joined with its N-terminal region through alternative splicing. The resulting 190-amino acid MiniFLASH, despite lacking 90% of full-length FLASH, contains all regions necessary for 3' end processing of histone pre-mRNA in vitro and accumulates in HLBs. © 2014 by The American Society for Biochemistry and Molecular Biology, Inc.
Khaodhiar, Lalita; Ricciotti, Hope A; Li, Linglin; Pan, Weijun; Schickel, Mary; Zhou, Jinrong; Blackburn, George L
2008-01-01
The aim of this study was to determine the effect of DRIs on hot flash symptoms in menopausal women. This was a randomized, double-blind, placebo-controlled trial of menopausal women, aged 38 to 60 years, who experienced 4 to 14 hot flashes per day. After a 1-week run-in period, a total of 190 menopausal women were randomized to receive a placebo or 40 or 60 mg/day of a DRI for 12 weeks. The primary outcome was the mean changes from baseline to week 12 in the frequency of hot flashes recorded in the participant diary. The secondary outcomes included changes in quality of life and hormonal profiles. A total of 147 women (77%) completed the study. It was found that 40 and 60 mg of DRI improved hot flash frequency and severity equally. At 8 weeks hot flash frequency was reduced by 43% in the 40-mg DRI group and by 41% in the 60-mg DRI group, compared with 32% in the placebo group (P = not significant vs placebo). The corresponding numbers for 12 weeks were 52%, 51%, and 39%, respectively (P = 0.07 and 0.09 vs placebo). When comparing the two treatment groups with the placebo group, there were significant reductions in mean daily hot flash frequency. The supplement (either 40 or 60 mg) reduced hot flash frequency by 43% at 8 weeks (P = 0.1) and 52% at 12 weeks (P = 0.048) but did not cause any significant changes in endogenous sex hormones or thyroid hormones. Menopausal quality of life improved in all three groups, although there were no statistically significant differences between groups. DRI supplementation may be an effective and acceptable alternative to hormone treatment for menopausal hot flashes.
Sievert, Lynnette L; Reza, Angela; Mills, Phoebe; Morrison, Lynn; Rahberg, Nichole; Goodloe, Amber; Sutherland, Michael; Brown, Daniel E
2010-01-01
The aims of this study were to test for a diurnal pattern in hot flashes in a multiethnic population living in a hot, humid environment and to examine the rates of concordance between objective and subjective measures of hot flashes using ambulatory and laboratory measures. Study participants aged 45 to 55 years were recruited from the general population of Hilo, HI. Women wore a Biolog hot flash monitor (UFI, Morro Bay, CA), kept a diary for 24 hours, and also participated in 3-hour laboratory measures (n = 199). Diurnal patterns were assessed using polynomial regression. For each woman, objectively recorded hot flashes that matched subjective experience were treated as true-positive readings. Subjective hot flashes were considered the standard for computing false-positive and false-negative readings. True-positive, false-positive, and false-negative readings were compared across ethnic groups by chi analyses. Frequencies of sternal, nuchal, and subjective hot flashes peaked at 1500 +/- 1 hours with no difference by ethnicity. Laboratory results supported the pattern seen in ambulatory monitoring. Sternal and nuchal monitoring showed the same frequency of true-positive measures, but nonsternal electrodes picked up more false-positive readings. Laboratory monitoring showed very low frequencies of false negatives. There were no ethnic differences in the frequency of true-positive or false-positive measures. Women of European descent were more likely to report hot flashes that were not objectively demonstrated (false-negative measures). The diurnal pattern and peak in hot flash occurrence in the hot humid environment of Hilo were similar to results from more temperate environments. Lack of variation in sternal versus nonsternal measures and in true-positive measures across ethnicities suggests no appreciable effect of population variation in sweating patterns.
Sievert, Lynnette L.; Reza, Angela; Mills, Phoebe; Morrison, Lynn; Rahberg, Nichole; Goodloe, Amber; Sutherland, Michael; Brown, Daniel E.
2010-01-01
Objective To test for a diurnal pattern in hot flashes in a multi-ethnic population living in a hot, humid environment. To examine rates of concordance between objective and subjective measures of hot flashes using ambulatory and laboratory measures. Methods Study participants aged 45–55 were recruited from the general population of Hilo, Hawaii. Women wore a Biolog hot flash monitor, kept a diary for 24-hours, and also participated in 3-hour laboratory measures (n=199). Diurnal patterns were assessed using polynomial regression. For each woman, objectively recorded hot flashes that matched subjective experience were treated as true positive readings. Subjective hot flashes were considered the standard for computing false positive and false negative readings. True positive, false positive, and false negative readings were compared across ethnic groups by chi-square analyses. Results Frequencies of sternal, nuchal and subjective hot flashes peaked at 15:00 ± 1 hour with no difference by ethnicity. Laboratory results supported the pattern seen in ambulatory monitoring. Sternal and nuchal monitoring showed the same frequency of true positive measures, but non-sternal electrodes picked up more false positive readings. Laboratory monitoring showed very low frequencies of false negatives. There were no ethnic differences in the frequency of true positive or false positive measures. Women of European descent were more likely to report hot flashes that were not objectively demonstrated (false negative measures). Conclusions The diurnal pattern and peak in hot flash occurrence in the hot humid environment of Hilo was similar to results from more temperate environments. Lack of variation in sternal vs. non-sternal measures, and in true positive measures across ethnicities suggests no appreciable effect of population variation in sweating patterns. PMID:20220538
Active Flash: Out-of-core Data Analytics on Flash Storage
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boboila, Simona; Kim, Youngjae; Vazhkudai, Sudharshan S
2012-01-01
Next generation science will increasingly come to rely on the ability to perform efficient, on-the-fly analytics of data generated by high-performance computing (HPC) simulations, modeling complex physical phenomena. Scientific computing workflows are stymied by the traditional chaining of simulation and data analysis, creating multiple rounds of redundant reads and writes to the storage system, which grows in cost with the ever-increasing gap between compute and storage speeds in HPC clusters. Recent HPC acquisitions have introduced compute node-local flash storage as a means to alleviate this I/O bottleneck. We propose a novel approach, Active Flash, to expedite data analysis pipelines bymore » migrating to the location of the data, the flash device itself. We argue that Active Flash has the potential to enable true out-of-core data analytics by freeing up both the compute core and the associated main memory. By performing analysis locally, dependence on limited bandwidth to a central storage system is reduced, while allowing this analysis to proceed in parallel with the main application. In addition, offloading work from the host to the more power-efficient controller reduces peak system power usage, which is already in the megawatt range and poses a major barrier to HPC system scalability. We propose an architecture for Active Flash, explore energy and performance trade-offs in moving computation from host to storage, demonstrate the ability of appropriate embedded controllers to perform data analysis and reduction tasks at speeds sufficient for this application, and present a simulation study of Active Flash scheduling policies. These results show the viability of the Active Flash model, and its capability to potentially have a transformative impact on scientific data analysis.« less
Dezentjé, Vincent O; Gelderblom, Hans; Van Schaik, Ron H N; Vletter-Bogaartz, Judith M; Van der Straaten, Tahar; Wessels, Judith A M; Kranenbarg, Elma Meershoek-Klein; Berns, Els M; Seynaeve, Caroline; Putter, Hein; Van de Velde, Cornelis J H; Nortier, Johan W R; Guchelaar, Henk-Jan
2014-01-01
In tamoxifen-treated breast cancer patients the occurrence of hot flashes may be associated with effective estrogen receptor antagonism dependent on genetic variations of metabolic enzymes and the estrogen receptor. Early breast cancer patients who were randomized to receive tamoxifen, followed by exemestane within the tamoxifen exemestane adjuvant multinational trial were genotyped for five CYP2D6 alleles. CYP2D6 genotypes and phenotypes were related to the occurrence of hot flashes as adverse event during the first year of tamoxifen use (primary aim) and the time to the occurrence of hot flashes as AE during the complete time on tamoxifen (secondary aim). In addition, exploratory analyses on 22 genetic variants of other metabolic enzymes and two common polymorphisms in the estrogen receptor-1 were performed. No association was found between the CYP2D6 genotype/phenotype or any other genetic variant and hot flashes during the first year. Only higher age was related to a lower incidence of hot flashes in the first year (adjusted odds ratio 0.94, 95 % CI 0.92-0.96; p < 0.001). The ESR1 PvuII XbaI CG haplotype was associated with the time to the occurrence of hot flashes during the complete time on tamoxifen (CG/CG vs. CG/other + other/other: adjusted hazard ratio 0.49, 95 % CI 0.25-0.97; p = 0.04). In conclusion, the CYP2D6 genotypes and phenotypes were not associated with the occurrence of hot flashes. Common polymorphisms in the estrogen receptor-1 might predict hot flashes as common tamoxifen side effect, although this finding needs replication.
von Spiczak, Jochen; Mannil, Manoj; Peters, Benjamin; Hickethier, Tilman; Baer, Matthias; Henning, André; Schmidt, Bernhard; Flohr, Thomas; Manka, Robert; Maintz, David; Alkadhi, Hatem
2018-05-23
The aims of this study were to assess the value of a dedicated sharp convolution kernel for photon counting detector (PCD) computed tomography (CT) for coronary stent imaging and to evaluate to which extent iterative reconstructions can compensate for potential increases in image noise. For this in vitro study, a phantom simulating coronary artery stenting was prepared. Eighteen different coronary stents were expanded in plastic tubes of 3 mm diameter. Tubes were filled with diluted contrast agent, sealed, and immersed in oil calibrated to an attenuation of -100 HU simulating epicardial fat. The phantom was scanned in a modified second generation 128-slice dual-source CT scanner (SOMATOM Definition Flash, Siemens Healthcare, Erlangen, Germany) equipped with both a conventional energy integrating detector and PCD. Image data were acquired using the PCD part of the scanner with 48 × 0.25 mm slices, a tube voltage of 100 kVp, and tube current-time product of 100 mAs. Images were reconstructed using a conventional convolution kernel for stent imaging with filtered back-projection (B46) and with sinogram-affirmed iterative reconstruction (SAFIRE) at level 3 (I463). For comparison, a dedicated sharp convolution kernel with filtered back-projection (D70) and SAFIRE level 3 (Q703) and level 5 (Q705) was used. The D70 and Q70 kernels were specifically designed for coronary stent imaging with PCD CT by optimizing the image modulation transfer function and the separation of contrast edges. Two independent, blinded readers evaluated subjective image quality (Likert scale 0-3, where 3 = excellent), in-stent diameter difference, in-stent attenuation difference, mathematically defined image sharpness, and noise of each reconstruction. Interreader reliability was calculated using Goodman and Kruskal's γ and intraclass correlation coefficients (ICCs). Differences in image quality were evaluated using a Wilcoxon signed-rank test. Differences in in-stent diameter difference, in-stent attenuation difference, image sharpness, and image noise were tested using a paired-sample t test corrected for multiple comparisons. Interreader and intrareader reliability were excellent (γ = 0.953, ICCs = 0.891-0.999, and γ = 0.996, ICCs = 0.918-0.999, respectively). Reconstructions using the dedicated sharp convolution kernel yielded significantly better results regarding image quality (B46: 0.4 ± 0.5 vs D70: 2.9 ± 0.3; P < 0.001), in-stent diameter difference (1.5 ± 0.3 vs 1.0 ± 0.3 mm; P < 0.001), and image sharpness (728 ± 246 vs 2069 ± 411 CT numbers/voxel; P < 0.001). Regarding in-stent attenuation difference, no significant difference was observed between the 2 kernels (151 ± 76 vs 158 ± 92 CT numbers; P = 0.627). Noise was significantly higher in all sharp convolution kernel images but was reduced by 41% and 59% by applying SAFIRE levels 3 and 5, respectively (B46: 16 ± 1, D70: 111 ± 3, Q703: 65 ± 2, Q705: 46 ± 2 CT numbers; P < 0.001 for all comparisons). A dedicated sharp convolution kernel for PCD CT imaging of coronary stents yields superior qualitative and quantitative image characteristics compared with conventional reconstruction kernels. Resulting higher noise levels in sharp kernel PCD imaging can be partially compensated with iterative image reconstruction techniques.
Van Dessel, Jeroen; Nicolielo, Laura Ferreira Pinheiro; Huang, Yan; Coudyzer, Walter; Salmon, Benjamin; Lambrichts, Ivo; Jacobs, Reinhilde
The aim of this study was to assess whether cone beam computed tomography (CBCT) may be used for clinically reliable alveolar bone quality assessment in comparison to its clinical alternatives, multislice computed tomography and the gold standard (micro-CT). Six dentate mandibular bone samples were scanned with seven CBCT devices (ProMax 3D Max, NewTom GiANO, Cranex 3D, 3D Accuitomo 170, Carestream 9300, Scanora 3D, I-CAT Next generation), one micro-CT scanner (SkyScan 1174) and one MSCT machine (Somatom Definition Flash) using two protocols (standard and high-resolution). MSCT and CBCT images were automatically spatially aligned on the micro-CT scan of the corresponding sample. A volume of interest was manually delineated on the micro-CT image and overlaid on the other scanning devices. Alveolar bone structures were automatically extracted using the adaptive thresholding algorithm. Based on the resulting binary images, an automatic 3D morphometric quantification was performed in a CT-Analyser (Bruker, Kontich, Belgium). The reliability and measurement errors were calculated for each modality compared to the gold standard micro-CT. Both MSCT and CBCT were associated with a clinically and statistically (P <0.05) significant measurement error. Bone quantity-related morphometric indices (bone volume fraction 8.41% min to 17.90% max, bone surface density -0.47 mm-1 min to 0.16 mm-1 max and trabecular thickness 0.15 mm min to 0.31 mm max) were significantly (P <0.05) overestimated, resulting in significantly (P <0.05) closer trabecular pores (total porosity percentage -8.41% min to -17.90% max and fractal dimension 0.08 min to 0.17 max) in all scanners compared to micro-CT. However, the structural pattern of the alveolar bone remained similar compared to that of the micro-CT for the ProMax 3D Max, NewTom GiANO, Cranex 3D, 3D Accuitomo 170 and Carestream 9300. On the other hand, the Scanora 3D, i-CAT Next Generation, standard and high-resolution MSCT displayed an overrated bone quantity and aberrant structural pattern compared to other scanning devices. The calculation of morphometric indices had an overall high reliability (intraclass correlation coefficient [ICC] 0.62 min to 0.99 max), except for the i-CAT Next Generation CBCT (ICC 0.26 min to 0.86 max) and standard resolution MSCT (ICC 0.10 min to 0.62 max). This study demonstrated that most CBCT machines may be able to quantitatively assess alveolar bone quality, with a level of accuracy and reliability that approaches micro-CT. One may therefore propose to extrapolate this to clinical CBCT imaging, certainly when there is a need for implant rehabilitation in dentate jaw bones. Conflict-of-interest statement: There is no conflict of interest to declare. Fellowship support was received from Research Foundation Flanders (FWO) from the Belgian government and from the Coordination for the Improvement of Higher Education Personnel (CAPES) programme, Science without Borders, from the Brazilian government.
The Distribution of Lightning Channel Lengths in Northern Alabama Thunderstorms
NASA Technical Reports Server (NTRS)
Peterson, H. S.; Koshak, W. J.
2010-01-01
Lightning is well known to be a major source of tropospheric NOx, and in most cases is the dominant natural source (Huntreiser et al 1998, Jourdain and Hauglustaine 2001). Production of NOx by a segment of a lightning channel is a function of channel segment energy density and channel segment altitude. A first estimate of NOx production by a lightning flash can be found by multiplying production per segment [typically 104 J/m; Hill (1979)] by the total length of the flash s channel. The purpose of this study is to determine average channel length for lightning flashes near NALMA in 2008, and to compare average channel length of ground flashes to the average channel length of cloud flashes.
All-season flash flood forecasting system for real-time operations
USDA-ARS?s Scientific Manuscript database
Flash floods can cause extensive damage to both life and property, especially because they are difficult to predict. Flash flood prediction requires high-resolution meteorologic observations and predictions, as well as calibrated hydrologic models in addition to extensive data handling. We have de...
DOT National Transportation Integrated Search
2015-05-01
Illuminated traffic control devices, such as rectangular rapid-flashing beacons (RRFB), have been shown to increase the number of drivers yielding to crossing pedestrians. There is some concern that the brightness of flashes at or contained within si...
DOT National Transportation Integrated Search
2013-08-01
Research was conducted to determine the effective intensity of flashing lights that incorporate light-emitting diodes (LEDs). LEDs require less power and have the ability to flash without the addition of moving parts. Compared with incandescent bulbs...
Investigation of Flash Fill{reg_sign} as a thermal backfill material
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ayers, P.H.; Charlton, C.B.; Frishette, C.W.
1995-09-01
Flash Fill{reg_sign} was created as a fast-setting, flowable backfill material made entirely from coal combustion by-products and water. Its quick-setting, self-leveling, self-compacting characteristics makes trench road repairs faster, easier, and more economical. Other uses include building foundations, fill around pipes, gas lines, and manholes, and replacement of weak subgrade beneath rooters. Flash Fill can be hand-excavated without the use of power assisted tools or machinery. To enhance thermal resistivity, the original Flash Fill mix was modified to include concrete sand. This resulted in a new Flash Fill, designated FSAND, with all of the aforementioned desirable characteristics of Flash Fill andmore » a thermal resistivity of approximately 50{degree} C-cm/watt. Thermal resistivity tests using conventional laboratory thermal probes, high-current thermal tests, and moisture migration tests have been performed to determine the properties of FSAND. As a result of these tests, FSAND has been approved for use as power cable thermal backfill on all AEP System distribution projects.« less
NASA Astrophysics Data System (ADS)
Miyaji, Kousuke; Sun, Chao; Soga, Ayumi; Takeuchi, Ken
2014-01-01
A relational database management system (RDBMS) is designed based on NAND flash solid-state drive (SSD) for storage. By vertically integrating the storage engine (SE) and the flash translation layer (FTL), system performance is maximized and the internal SSD overhead is minimized. The proposed RDBMS SE utilizes physical information about the NAND flash memory which is supplied from the FTL. The query operation is also optimized for SSD. By these treatments, page-copy-less garbage collection is achieved and data fragmentation in the NAND flash memory is suppressed. As a result, RDBMS performance increases by 3.8 times, power consumption of SSD decreases by 46% and SSD life time is increased by 61%. The effectiveness of the proposed scheme increases with larger erase block sizes, which matches the future scaling trend of three-dimensional (3D-) NAND flash memories. The preferable row data size of the proposed scheme is below 500 byte for 16 kbyte page size.
Ghazanfarpour, M; Sadeghi, R; Roudsari, R Latifnejad; Khorsand, I; Khadivzadeh, T; Muoio, B
2016-01-01
This study evaluated the efficacy of red clover to relieve hot flashes and menopausal symptoms in peri/postmenopausal women. Electronic databases (MEDLINE, Scopus and the Cochrane Library) were searched. The mean frequency of hot flashes in red clover groups was lower compared with that in the control groups (close to statistical significance). Difference in means (MD) of hot flashes frequency was - 1.99 (- 4.12-0.139; p = 0.067; heterogeneity P > 0.01; I(2) = 94.93%; Random effect model). Subjective (vaginal dryness) and objective (maturation value) symptoms of vaginal atrophy showed a significant improvement with 80-mg dose of red clover. Red clover showed less therapeutic effect on psychology status, sexual problems and sleeping disorders. Red clover consumption may decrease frequency of hot flashes, especially in women with severe hot flashes (≥ 5 per day). Red clover may reduce other menopausal symptoms. Further trials are needed to confirm the current systematic review findings.
Mortality from flash floods: a review of national weather service reports, 1969-81.
French, J; Ing, R; Von Allmen, S; Wood, R
1983-01-01
Of all weather-related disasters that occur in the United States, floods are the main cause of death, and most flood-related deaths are attributed to flash floods. Whenever a weather-related disaster involves 30 or more deaths or more than $100 million in property damage, the National Weather Service (NWS) forms a survey team to investigate the disaster and write a report of findings. All NWS survey reports on flash floods issued during 1969-81 were reviewed to determine the mortality resulting from such floods, the effect of warnings on mortality, and the circumstances contributing to death. A total of 1,185 deaths were associated with 32 flash floods, an average of 37 deaths per flash flood. The highest average number of deaths per event was associated with the four flash floods in which dams broke after heavy rains. Although there were 18 flash floods in 1977-81 and only 14 in 1969-76, the number of deaths was 2 1/2 times greater during the earlier period. More than twice as many deaths were associated with flash floods for which the survey team considered the warnings inadequate than with those with warnings considered adequate. Ninety-three percent of the deaths were due to drowning and 42 percent of these drownings were car related. The other drownings occurred in homes, at campsites, or when persons were crossing bridges and streams. The need for monitoring dams during periods of heavy rainfall is highlighted. PMID:6419273
Sternal Skin Conductance: A reasonable surrogate for Hot Flash Measurement?
Pachman, Deirdre R.; Loprinzi, Charles L.; Novotny, Paul J; Satele, Daniel V; Linquist, Breanna M.; Wolf, Sherry; Barton, Debra L.
2013-01-01
Objective The aim of this study was to examine the accuracy of a new sternal skin conductance (SSC) device for the measurement of hot flashes, and secondly, to assess the acceptability of the device by women. Methods Three small descriptive pilot studies were performed utilizing two sequential prototypes of the SSC device developed by an engineering device company in the Midwest. The devices were worn either in a monitored setting for 24 hours or in an ambulatory setting for 5 weeks. During the study period, women recorded hot flashes in a prospective hot flash diary and also answered questions about the acceptability of wearing the SSC device. Results The first prototype was not able to collect any analyzable skin conductance data due to various malfunction issues; including poor conductance and battery failure. However, 16 patients did wear the device for 5 weeks and reported that wearing the device was acceptable, although 31% stated that it did interfere with daily activities. Hot flash data from the second prototype revealed a concordance rate between patient reported and device recorded hot flashes of 24%. Conclusions Findings from these studies support the discordance between SSC recorded and patient reported hot flashes. In addition, the studies reveal further limitations of SSC monitoring, including difficulties with data collection and lack of consistency in interpretation. Based on these results and other recent trials identifying issues with SSC methodology, it is time to find a better physiologic surrogate measure for hot flashes. PMID:23571528
Vitamin Content of Breast Milk From HIV-1–Infected Mothers Before and After Flash-Heat Treatment
Israel-Ballard, Kiersten A.; Abrams, Barbara F.; Coutsoudis, Anna; Sibeko, Lindiwe N.; Cheryk, Lynn A.; Chantry, Caroline J.
2010-01-01
Background World Health Organization advocates heat treatment of expressed breastmilk (EBM) as one method to reduce postnatal transmission of human immunodeficiency virus (HIV) in developing countries. Flash-heat is a simple heat treatment method shown to inactivate cell-free HIV. Objective To determine the effect of flash-heat on vitamin content of milk. Methods Fresh EBM was collected from 50 HIV+ mothers in Durban, South Africa. Mothers washed their hands and then manually expressed 75–150 mL EBM into sterile jars. Milk was aliquoted to unheated controls or flash-heat (50 mL EBM in a glass jar heated in a 450-mL water jacket in an aluminum pan until water boiled, then EBM removed) simulating field conditions with an open flame. Samples were stored at −70°C and then analyzed for the effect of flash-heat on vitamins [A, ascorbic acid, riboflavin (B2), pyridoxal-5-phosphate (B6), folate, and B12]. Results Vitamin A was not significantly affected by flash-heat and vitamins B12 and C and folate increased significantly. Vitamins B2 and B6 were decreased to 59% (95% confidence interval 44 to 81) and 96% (95% confidence interval 92 to 99), respectively, of that found in unheated milk. Conclusions The percentage remaining after flash-heat suggests that most vitamin concentrations are retained after heating. Flash-heat may be a practical and nutritious infant feeding method for mothers in developing countries. PMID:18614920
Pérez-Alcalá, Irene; Sievert, Lynnette Leidy; Obermeyer, Carla Makhlouf; Reher, David Sven
2013-01-01
Objective This study applies a biocultural perspective to better understand the determinants of hot flashes and night sweats within immigrant and local populations in Madrid, Spain. Methods A combined sample of 575 women from Madrid, aged 45 to 55, was drawn from two studies. The Spanish sample (n=274) participated in the Decisions at Menopause Study (DAMES) in 2000–2002. The Latin-American sample (n=301) was drawn from immigrants to Madrid in 2010–2011. Chi square analyses and logistic regression models were carried out among the combined controlling by origin of provenance. Results Forty four percent of the women reported hot flashes, 36% reported night sweats and 26% both symptoms. Compared to Spanish women, Latin-American women were less likely to report hot flashes (OR 0.7, 95% CI 0.4–0.9) after controlling for demographic variables and menopausal status. The same was not found for night sweats and for both symptoms combined. Determinants of hot flashes differed from determinants of night sweats. Conclusions Because determinants differed, hot flashes and night sweats should be queried and analyzed separately. Latin-American women were less likely to report hot flashes, but not night sweats or both symptoms combined. More research is needed to clarify the differences in reported hot flashes as the lesser report among immigrants could have been a cultural rather than a biological phenomenon. PMID:23571525
Vitamin content of breast milk from HIV-1-infected mothers before and after flash-heat treatment.
Israel-Ballard, Kiersten A; Abrams, Barbara F; Coutsoudis, Anna; Sibeko, Lindiwe N; Cheryk, Lynn A; Chantry, Caroline J
2008-08-01
World Health Organization advocates heat treatment of expressed breastmilk (EBM) as one method to reduce postnatal transmission of human immunodeficiency virus (HIV) in developing countries. Flash-heat is a simple heat treatment method shown to inactivate cell-free HIV. To determine the effect of flash-heat on vitamin content of milk. Fresh EBM was collected from 50 HIV+ mothers in Durban, South Africa. Mothers washed their hands and then manually expressed 75-150 mL EBM into sterile jars. Milk was aliquoted to unheated controls or flash-heat (50 mL EBM in a glass jar heated in a 450-mL water jacket in an aluminum pan until water boiled, then EBM removed) simulating field conditions with an open flame. Samples were stored at -70 degrees C and then analyzed for the effect of flash-heat on vitamins [A, ascorbic acid, riboflavin (B2), pyridoxal-5-phosphate (B6), folate, and B12]. Vitamin A was not significantly affected by flash-heat and vitamins B12 and C and folate increased significantly. Vitamins B2 and B6 were decreased to 59% (95% confidence interval 44 to 81) and 96% (95% confidence interval 92 to 99), respectively, of that found in unheated milk. The percentage remaining after flash-heat suggests that most vitamin concentrations are retained after heating. Flash-heat may be a practical and nutritious infant feeding method for mothers in developing countries.
Impact of rainfall spatial variability on Flash Flood Forecasting
NASA Astrophysics Data System (ADS)
Douinot, Audrey; Roux, Hélène; Garambois, Pierre-André; Larnier, Kevin
2014-05-01
According to the United States National Hazard Statistics database, flooding and flash flooding have caused the largest number of deaths of any weather-related phenomenon over the last 30 years (Flash Flood Guidance Improvement Team, 2003). Like the storms that cause them, flash floods are very variable and non-linear phenomena in time and space, with the result that understanding and anticipating flash flood genesis is far from straightforward. In the U.S., the Flash Flood Guidance (FFG) estimates the average number of inches of rainfall for given durations required to produce flash flooding in the indicated county. In Europe, flash flood often occurred on small catchments (approximately 100 km2) and it has been shown that the spatial variability of rainfall has a great impact on the catchment response (Le Lay and Saulnier, 2007). Therefore, in this study, based on the Flash flood Guidance method, rainfall spatial variability information is introduced in the threshold estimation. As for FFG, the threshold is the number of millimeters of rainfall required to produce a discharge higher than the discharge corresponding to the first level (yellow) warning of the French flood warning service (SCHAPI: Service Central d'Hydrométéorologie et d'Appui à la Prévision des Inondations). The indexes δ1 and δ2 of Zoccatelli et al. (2010), based on the spatial moments of catchment rainfall, are used to characterize the rainfall spatial distribution. Rainfall spatial variability impacts on warning threshold and on hydrological processes are then studied. The spatially distributed hydrological model MARINE (Roux et al., 2011), dedicated to flash flood prediction is forced with synthetic rainfall patterns of different spatial distributions. This allows the determination of a warning threshold diagram: knowing the spatial distribution of the rainfall forecast and therefore the 2 indexes δ1 and δ2, the threshold value is read on the diagram. A warning threshold diagram is built for each studied catchment. The proposed methodology is applied on three Mediterranean catchments often submitted to flash floods. The new forecasting method as well as the Flash Flood Guidance method (uniform rainfall threshold) are tested on 25 flash floods events that had occurred on those catchments. Results show a significant impact of rainfall spatial variability. Indeed, it appears that the uniform rainfall threshold (FFG threshold) always overestimates the observed rainfall threshold. The difference between the FFG threshold and the proposed threshold ranges from 8% to 30%. The proposed methodology allows the calculation of a threshold more representative of the observed one. However, results strongly depend on the related event duration and on the catchment properties. For instance, the impact of the rainfall spatial variability seems to be correlated with the catchment size. According to these results, it seems to be interesting to introduce information on the catchment properties in the threshold calculation. Flash Flood Guidance Improvement Team, 2003. River Forecast Center (RFC) Development Management Team. Final Report. Office of Hydrologic Development (OHD), Silver Spring, Mary-land. Le Lay, M. and Saulnier, G.-M., 2007. Exploring the signature of climate and landscape spatial variabilities in flash flood events: Case of the 8-9 September 2002 Cévennes-Vivarais catastrophic event. Geophysical Research Letters, 34(L13401), doi:10.1029/2007GL029746. Roux, H., Labat, D., Garambois, P.-A., Maubourguet, M.-M., Chorda, J. and Dartus, D., 2011. A physically-based parsimonious hydrological model for flash floods in Mediterranean catchments. Nat. Hazards Earth Syst. Sci. J1 - NHESS, 11(9), 2567-2582. Zoccatelli, D., Borga, M., Zanon, F., Antonescu, B. and Stancalie, G., 2010. Which rainfall spatial information for flash flood response modelling? A numerical investigation based on data from the Carpathian range, Romania. Journal of Hydrology, 394(1-2), 148-161.
NASA Technical Reports Server (NTRS)
Irom, Farokh; Nguyen, Duc N.
2010-01-01
High-density, commercial, nonvolatile flash memories with NAND architecture are now available from several manufacturers. This report examines SEE effects and TID response in single-level cell (SLC) and multi-level cell (MLC) NAND flash memories manufactured by Micron Technology.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-28
... Comment Request; Family Life, Activity, Sun, Health, and Eating (FLASHE) Study (NCI) Summary: In.... Proposed Collection: Family Life, Activity, Sun, Health, and Eating (FLASHE) Study 0925--NEW, National... FLASHE study seeks to examine psychosocial, generational (parent-adolescent), and environmental...
A Photogate Flash Trigger and a Demonstration of Inertia.
ERIC Educational Resources Information Center
Winters, Loren
1992-01-01
Describes a photogate electronic flash trigger that synchronizes flash discharge with high-speed events. Presents a photographic study of a high-speed collision demonstrating the passage of a BB through an elastic strip. Provides the schematic of the delay circuit utilized in the trigger. (MDH)
Two-flash thresholds as a function of comparison stimulus duration.
DOT National Transportation Integrated Search
1970-09-01
The proposal that two-flash thresholds may be used as direct measures of the critical duration (tc) of Bloch's law was tested. Two-flash threshold was found to be an increasing function of comparison stimulus duration for durations of 3 to 22 msec. i...
Flash Study Analysis and the Music Learning Pro-Files Project
ERIC Educational Resources Information Center
Cremata, Radio; Pignato, Joseph; Powell, Bryan; Smith, Gareth Dylan
2016-01-01
This paper introduces the Music Learning Profiles Project, and its methodological approach, flash study analysis. Flash study analysis is a method that draws heavily on extant qualitative approaches to education research, to develop broad understandings of music learning in diverse contexts. The Music Learning Profiles Project (MLPP) is an…
NASA Technical Reports Server (NTRS)
Irom, Farokh; Nguyen, Duc N.
2011-01-01
High-density, commercial, nonvolatile flash memories with NAND architecture are now available from several manufacturers. This report examines SEE effects and TID response in single-level cell (SLC) 32Gb and multi-level cell (MLC) 64Gb NAND flash memories manufactured by Micron Technology.
33 CFR 117.253 - Anacostia River.
Code of Federal Regulations, 2013 CFR
2013-07-01
... open position for vessel traffic. During open span movement, the channel traffic lights will flash red... traffic lights will flash red, and an audio voice-warning device will announce bridge movement during... will continue to flash red. (6) The owners of the bridge shall provide and keep in good legible...
33 CFR 117.253 - Anacostia River.
Code of Federal Regulations, 2014 CFR
2014-07-01
... open position for vessel traffic. During open span movement, the channel traffic lights will flash red... traffic lights will flash red, and an audio voice-warning device will announce bridge movement during... will continue to flash red. (6) The owners of the bridge shall provide and keep in good legible...
33 CFR 117.253 - Anacostia River.
Code of Federal Regulations, 2012 CFR
2012-07-01
... open position for vessel traffic. During open span movement, the channel traffic lights will flash red... traffic lights will flash red, and an audio voice-warning device will announce bridge movement during... will continue to flash red. (6) The owners of the bridge shall provide and keep in good legible...
DOT National Transportation Integrated Search
1968-10-01
Signal lights are presented to an observer as flashes with finite duration; thus, the effect of flash duration on the apparent brightness of the signal is important. The relation of effective signal brightness to flash duration and luminance finds ex...
Non Volatile Flash Memory Radiation Tests
NASA Technical Reports Server (NTRS)
Irom, Farokh; Nguyen, Duc N.; Allen, Greg
2012-01-01
Commercial flash memory industry has experienced a fast growth in the recent years, because of their wide spread usage in cell phones, mp3 players and digital cameras. On the other hand, there has been increased interest in the use of high density commercial nonvolatile flash memories in space because of ever increasing data requirements and strict power requirements. Because of flash memories complex structure; they cannot be treated as just simple memories in regards to testing and analysis. It becomes quite challenging to determine how they will respond in radiation environments.
Spectroscopic measurements of muzzle flash plasma
NASA Astrophysics Data System (ADS)
Uglum, J. R.
1986-11-01
The experimental apparatus and sample data for the muzzle flash plasma of a laboratory-scale railgun are described. Theoretical predictions for the railgun system configuration used indicated that 24 kJ of energy would be dissipated by the muzzle flash. Spectral data were recorded with a spectrograph sensing through a slit and a PIN diode, the latter to obtain temporal resolution in the data. The tests featured a plastic projectile with an Al foil armature. The measurements identified Cu as the dominant flash material, ablated from the rails in the barrel.
Remote sensing of rainfall for flash flood prediction in the United States
NASA Astrophysics Data System (ADS)
Gourley, J. J.; Flamig, Z.; Vergara, H. J.; Clark, R. A.; Kirstetter, P.; Terti, G.; Hong, Y.; Howard, K.
2015-12-01
This presentation will briefly describe the Multi-Radar Multi-Sensor (MRMS) system that ingests all NEXRAD and Canadian weather radar data and produces accurate rainfall estimates at 1-km resolution every 2 min. This real-time system, which was recently transitioned for operational use in the National Weather Service, provides forcing to a suite of flash flood prediction tools. The Flooded Locations and Simulated Hydrographs (FLASH) project provides 6-hr forecasts of impending flash flooding across the US at the same 1-km grid cell resolution as the MRMS rainfall forcing. This presentation will describe the ensemble hydrologic modeling framework, provide an evaluation at gauged basins over a 10-year period, and show the FLASH tools' performance during the record-setting floods in Oklahoma and Texas in May and June 2015.
FLASH Technology: Full-Scale Hospital Waste Water Treatments Adopted in Aceh
NASA Astrophysics Data System (ADS)
Rame; Tridecima, Adeodata; Pranoto, Hadi; Moesliem; Miftahuddin
2018-02-01
A Hospital waste water contains a complex mixture of hazardous chemicals and harmful microbes, which can pose a threat to the environment and public health. Some efforts have been carried out in Nangroe Aceh Darussalam (Aceh), Indonesia with the objective of treating hospital waste water effluents on-site before its discharge. Flash technology uses physical and biological pre-treatment, followed by advanced oxidation process based on catalytic ozonation and followed by GAC and PAC filtration. Flash Full-Scale Hospital waste water Treatments in Aceh from different district have been adopted and investigated. Referring to the removal efficiency of macro-pollutants, the collected data demonstrate good removal efficiency of macro-pollutants using Flash technologies. In general, Flash technologies could be considered a solution to the problem of managing hospital waste water.
Modeling experimental plasma diagnostics in the FLASH code: Thomson scattering
NASA Astrophysics Data System (ADS)
Weide, Klaus; Flocke, Norbert; Feister, Scott; Tzeferacos, Petros; Lamb, Donald
2017-10-01
Spectral analysis of the Thomson scattering of laser light sent into a plasma provides an experimental method to quantify plasma properties in laser-driven plasma experiments. We have implemented such a synthetic Thomson scattering diagnostic unit in the FLASH code, to emulate the probe-laser propagation, scattering and spectral detection. User-defined laser rays propagate into the FLASH simulation region and experience scattering (change in direction and frequency) based on plasma parameters. After scattering, the rays propagate out of the interaction region and are spectrally characterized. The diagnostic unit can be used either during a physics simulation or in post-processing of simulation results. FLASH is publicly available at flash.uchicago.edu. U.S. DOE NNSA, U.S. DOE NNSA ASC, U.S. DOE Office of Science and NSF.
Compatibility of motion facilitates visuomotor synchronization.
Hove, Michael J; Spivey, Michael J; Krumhansl, Carol L
2010-12-01
Prior research indicates that synchronized tapping performance is very poor with flashing visual stimuli compared with auditory stimuli. Three finger-tapping experiments compared flashing visual metronomes with visual metronomes containing a spatial component, either compatible, incompatible, or orthogonal to the tapping action. In Experiment 1, synchronization success rates increased dramatically for spatiotemporal sequences of both geometric and biological forms over flashing sequences. In Experiment 2, synchronization performance was best when target sequences and movements were directionally compatible (i.e., simultaneously down), followed by orthogonal stimuli, and was poorest for incompatible moving stimuli and flashing stimuli. In Experiment 3, synchronization performance was best with auditory sequences, followed by compatible moving stimuli, and was worst for flashing and fading stimuli. Results indicate that visuomotor synchronization improves dramatically with compatible spatial information. However, an auditory advantage in sensorimotor synchronization persists.
The design of the light-flash warning light
NASA Astrophysics Data System (ADS)
Wang, Junli
2018-05-01
In today's society, the warning light has been used widely in people's daily life and various industries and agricultures. It is important to protect people's life and security. Light-flashing warning light is a kind of warning light control equipment which can control warning light automatically open and work in the state of blinking after dark, and it can automatically shut down after the dawn. It can achieve the flashing light automatic control and dual function. At present, light-flashing warning lights are mainly used in the projects of municipal construction. It is helpful to warn people and vehicles that passed in the construction site and ensure personal safety through using light-flashing warning light. Its design is simple, its performance is stable and it is also very convince to use it.
A comparison of colour, shape, and flash induced illusory line motion.
Hamm, Jeff P
2017-04-01
When a bar suddenly appears between two boxes, the bar will appear to shoot away from the box that matches it in colour or in shape-a phenomenon referred to as attribute priming of illusory line motion (ILM; colour ILM and shape ILM, respectively). If the two boxes are identical, ILM will still occur away from a box if it changes luminance shortly before the presentation of the bar ( flash ILM). This flash condition has been suggested to produce the illusory motion due to the formation of an attentional gradient surrounding the flashed location. However, colour ILM and shape ILM cannot be explained by an attentional gradient as there is no way for attention to select the matching box prior to the presentation of the bar. These findings challenge the attentional gradient explanation for ILM, but only if it is assumed that ILM arises for the same underlying reason. Two experiments are presented that address the question of whether or not flash ILM is the same as colour ILM or shape ILM. The results suggest that while colour ILM and shape ILM reflect a common illusion, flash ILM arises for a different reason. Therefore, the attentional gradient explanation for flash ILM is not refuted by the occurrence of colour ILM or shape ILM, which may reflect transformational apparent motion (TAM).
Increased Expression of CCN2 in the Red Flashing Light-Induced Myopia in Guinea Pigs
Wang, Hong; Zhuang, Kang; Gao, Lei; Zhang, Linna; Yang, Hongling
2013-01-01
Visual environment plays an important role in the occurrence of myopia. We previously showed that the different flashing lights could result in distinct effects on the ocular growth and development of myopia. CCN2 has been reported to regulate various cellular functions and biological processes. However, whether CCN2 signaling was involved in the red flashing light-induced myopia still remains unknown. In the present study, we investigated the effects of the red flashing lights exposure on the refraction and axial length of the eyes in vivo and then evaluated their effects on the expression of CCN2 and TGF-β in sclera tissues. Our data showed that the eyes exposed to the red flashing light became more myopic with a significant increase of the axial length and decrease of the refraction. Both CCN2 and TGF-β, as well as p38 MAPK and PI3K, were highly expressed in the sclera tissues exposed to the red flashing light. Both CCN2 and TGF-β were found to have the same gene expression profile in vivo. In conclusion, our findings found that CCN2 signaling pathway plays an important role in the red flashing light-induced myopia in vivo. Moreover, our study establishes a useful animal model for experimental myopia research. PMID:23936844
Kim, Eung Seok; Choi, Hyun Il
2012-01-01
An increase in the occurrence of sudden local flooding of great volume and short duration has caused significant danger and loss of life and property in Korea as well as many other parts of the World. Since such floods usually accompanied by rapid runoff and debris flow rise quite quickly with little or no advance warning to prevent flood damage, this study presents a new flash flood indexing methodology to promptly provide preliminary observations regarding emergency preparedness and response to flash flood disasters in small ungauged catchments. Flood runoff hydrographs are generated from a rainfall-runoff model for the annual maximum rainfall series of long-term observed data in the two selected small ungauged catchments. The relative flood severity factors quantifying characteristics of flood runoff hydrographs are standardized by the highest recorded maximum value, and then averaged to obtain the flash flood index only for flash flood events in each study catchment. It is expected that the regression equations between the proposed flash flood index and rainfall characteristics can provide the basis database of the preliminary information for forecasting the local flood severity in order to facilitate flash flood preparedness in small ungauged catchments. PMID:22690208
Flash floods in the Tatra Mountain streams: frequency and triggers.
Ballesteros-Cánovas, J A; Czajka, B; Janecka, K; Lempa, M; Kaczka, R J; Stoffel, M
2015-04-01
Flash floods represent a frequently recurring natural phenomenon in the Tatra Mountains. On the northern slopes of the mountain chain, located in Poland, ongoing and expected future changes in climate are thought to further increase the adverse impacts of flash floods. Despite the repeat occurrence of major floods in the densely populated foothills of the Polish Tatras, the headwaters have been characterized by a surprising lack of data, such that any analysis of process variability or hydrometeorological triggers has been largely hampered so far. In this study, dendrogeomorphic techniques have been employed in four poorly-gauged torrential streams of the northern slope of the Tatra Mountains to reconstruct temporal and spatial patterns of past events. Using more than 1100 increment cores of trees injured by past flash floods, we reconstruct 47 events covering the last 148 years and discuss synoptic situations leading to the triggering of flash floods with the existing meteorological and flow gauge data. Tree-ring analyses have allowed highlighting the seasonality of events, providing new insights about potential hydrometeorological triggers as well as a differentiating flash flood activity between catchments. Results of this study could be useful to design future strategies to deal with flash flood risks at the foothills of the Polish Tatras and in the Vistula River catchment. Copyright © 2014. Published by Elsevier B.V.
Additions and improvements to the high energy density physics capabilities in the FLASH code
NASA Astrophysics Data System (ADS)
Lamb, D.; Bogale, A.; Feister, S.; Flocke, N.; Graziani, C.; Khiar, B.; Laune, J.; Tzeferacos, P.; Walker, C.; Weide, K.
2017-10-01
FLASH is an open-source, finite-volume Eulerian, spatially-adaptive radiation magnetohydrodynamics code that has the capabilities to treat a broad range of physical processes. FLASH performs well on a wide range of computer architectures, and has a broad user base. Extensive high energy density physics (HEDP) capabilities exist in FLASH, which make it a powerful open toolset for the academic HEDP community. We summarize these capabilities, emphasizing recent additions and improvements. We describe several non-ideal MHD capabilities that are being added to FLASH, including the Hall and Nernst effects, implicit resistivity, and a circuit model, which will allow modeling of Z-pinch experiments. We showcase the ability of FLASH to simulate Thomson scattering polarimetry, which measures Faraday due to the presence of magnetic fields, as well as proton radiography, proton self-emission, and Thomson scattering diagnostics. Finally, we describe several collaborations with the academic HEDP community in which FLASH simulations were used to design and interpret HEDP experiments. This work was supported in part at U. Chicago by DOE NNSA ASC through the Argonne Institute for Computing in Science under FWP 57789; DOE NNSA under NLUF Grant DE-NA0002724; DOE SC OFES Grant DE-SC0016566; and NSF Grant PHY-1619573.
Spectral measurements of muzzle flash with multispectral and hyperspectral sensor
NASA Astrophysics Data System (ADS)
Kastek, M.; Dulski, R.; Trzaskawka, P.; Piątkowski, T.; Polakowski, H.
2011-08-01
The paper presents some practical aspects of the measurements of muzzle flash signatures. Selected signatures of sniper shot in typical scenarios has been presented. Signatures registered during all phases of muzzle flash were analyzed. High precision laboratory measurements were made in a special ballistic laboratory and as a result several flash patterns were registered. The field measurements of a muzzle flash were also performed. During the tests several infrared cameras were used, including the measurement class devices with high accuracy and frame rates. The registrations were made in NWIR, SWIR and LWIR spectral bands simultaneously. An ultra fast visual camera was also used for visible spectra registration. Some typical infrared shot signatures were presented. Beside the cameras, the LWIR imaging spectroradiometer HyperCam was also used during the laboratory experiments and the field tests. The signatures collected by the HyperCam device were useful for the determination of spectral characteristics of the muzzle flash, whereas the analysis of thermal images registered during the tests provided the data on temperature distribution in the flash area. As a result of the measurement session the signatures of several types handguns, machine guns and sniper rifles were obtained which will be used in the development of passive infrared systems for sniper detection.
The Triple-Flash Illusion Reveals a Driving Role of Alpha-Band Reverberations in Visual Perception.
Gulbinaite, Rasa; İlhan, Barkın; VanRullen, Rufin
2017-07-26
The modulatory role of spontaneous brain oscillations on perception of threshold-level stimuli is well established. Here, we provide evidence that alpha-band (∼10 Hz) oscillations not only modulate perception of threshold-level sensory inputs but also can drive perception and generate percepts without a physical stimulus being present. We used the "triple-flash" illusion: Occasional perception of three flashes when only two spatially coincident veridical ones, separated by ∼100 ms, are presented. The illusion was proposed to result from superposition of two hypothetical oscillatory impulse response functions generated in response to each flash: When the delay between flashes matches the period of the oscillation, the superposition enhances a later part of the oscillation that is normally damped; when this enhancement crosses perceptual threshold, a third flash is erroneously perceived (Bowen, 1989). In Experiment 1, we varied stimulus onset asynchrony and validated Bowen's theory: The optimal stimulus onset asynchrony for illusion to occur was correlated, across human subjects (both genders), with the subject-specific impulse response function period determined from a separate EEG experiment. Experiment 2 revealed that prestimulus parietal, but no occipital, alpha EEG phase and power, as well as poststimulus alpha phase-locking, together determine the occurrence of the illusion on a trial-by-trial basis. Thus, oscillatory reverberations create something out of nothing: A third flash where there are only two. SIGNIFICANCE STATEMENT We highlight a novel property of alpha-band (∼10 Hz) oscillations based on three experiments (two EEG and one psychophysics) by demonstrating that alpha-band oscillations do not merely modulate perception, but can also drive perception. We show that human participants report seeing a third flash when only two are presented (the "triple-flash" illusion) most often when the interflash delay matches the period of participant's oscillatory impulse response function reverberating in alpha. Within-subject, the phase and power of ongoing parietal, but not occipital, alpha-band oscillations at the time of the first flash determine illusory percept on a trial-by-trial basis. We revealed a physiologically plausible mechanism that validates and extends the original theoretical account of the triple-flash illusion proposed by Bowen in 1989. Copyright © 2017 the authors 0270-6474/17/377219-12$15.00/0.
NASA Technical Reports Server (NTRS)
Solakiewiz, Richard; Koshak, William
2008-01-01
Continuous monitoring of the ratio of cloud flashes to ground flashes may provide a better understanding of thunderstorm dynamics, intensification, and evolution, and it may be useful in severe weather warning. The National Lighting Detection Network TM (NLDN) senses ground flashes with exceptional detection efficiency and accuracy over most of the continental United States. A proposed Geostationary Lightning Mapper (GLM) aboard the Geostationary Operational Environmental Satellite (GOES-R) will look at the western hemisphere, and among the lightning data products to be made available will be the fundamental optical flash parameters for both cloud and ground flashes: radiance, area, duration, number of optical groups, and number of optical events. Previous studies have demonstrated that the optical flash parameter statistics of ground and cloud lightning, which are observable from space, are significantly different. This study investigates a Bayesian network methodology for discriminating lightning flash type (ground or cloud) using the lightning optical data and ancillary GOES-R data. A Directed Acyclic Graph (DAG) is set up with lightning as a "root" and data observed by GLM as the "leaves." This allows for a direct calculation of the joint probability distribution function for the lighting type and radiance, area, etc. Initially, the conditional probabilities that will be required can be estimated from the Lightning Imaging Sensor (LIS) and the Optical Transient Detector (OTD) together with NLDN data. Directly manipulating the joint distribution will yield the conditional probability that a lightning flash is a ground flash given the evidence, which consists of the observed lightning optical data [and possibly cloud data retrieved from the GOES-R Advanced Baseline Imager (ABI) in a more mature Bayesian network configuration]. Later, actual GLM and NLDN data can be used to refine the estimates of the conditional probabilities used in the model; i.e., the Bayesian network is a learning network. Methods for efficient calculation of the conditional probabilities (e.g., an algorithm using junction trees), finding data conflicts, goodness of fit, and dealing with missing data will also be addressed.
Chromatic induction in space and time.
Coia, Andrew J; Shevell, Steven K
2018-04-01
The color appearance of a light depends on variation in the complete visual field over both space and time. In the spatial domain, a chromatic stimulus within a patterned chromatic surround can appear a different hue than the same stimulus within a uniform surround. In the temporal domain, a stimulus presented as an element of a continuously changing chromaticity can appear a different color compared to the identical stimulus, presented simultaneously but viewed alone. This is the flash-lag effect for color, which has an analog in the domain of motion: a pulsed object seen alone can appear to lag behind an identical pulsed object that is an element of a motion sequence. Studies of the flash-lag effect for motion have considered whether it is mediated by a neural representation for the moving physical stimulus or, alternatively, for the perceived motion. The current study addresses this question for the flash-lag effect for color by testing whether the color flash lag depends on a representation of only the changing chromatic stimulus or, alternatively, its color percept, which can be altered by chromatic induction. baseline measurements for spatial chromatic induction determined the chromaticity of a flashed ring within a uniform surround that matched a flashed ring within a patterned surround. Baseline measurements for the color flash-lag effect determined the chromaticity of a pulsed ring presented alone (within a uniform surround) that matched a pulsed ring presented in a sequence of changing chromaticity over time (also within a uniform surround). Finally, the main experiments combined chromatic induction from a patterned surround and the flash-lag effect, in three conditions: (1) both the changing and pulsed rings were within a patterned chromatic surround; (2) the changing ring was within a patterned surround and the pulsed ring within a uniform surround; and (3) the changing ring was within a uniform surround and the pulsed ring within a patterned surround. the flash-lag measurements for a changing chromaticity were affected by perceptual changes induced by the surrounding chromatic pattern. Thus, the color shifts induced by a chromatic surround are incorporated in the neural representation mediating the flash-lag effect for color.
NASA Astrophysics Data System (ADS)
Pillosu, F. M.; Jurlina, T.; Baugh, C.; Tsonevsky, I.; Hewson, T.; Prates, F.; Pappenberger, F.; Prudhomme, C.
2017-12-01
During hurricane Harvey the greater east Texas area was affected by extensive flash flooding. Their localised nature meant they were too small for conventional large scale flood forecasting systems to capture. We are testing the use of two real time forecast products from the European Centre for Medium-range Weather Forecasts (ECMWF) in combination with local vulnerability information to provide flash flood forecasting tools at the medium range (up to 7 days ahead). Meteorological forecasts are the total precipitation extreme forecast index (EFI), a measure of how the ensemble forecast probability distribution differs from the model-climate distribution for the chosen location, time of year and forecast lead time; and the shift of tails (SOT) which complements the EFI by quantifying how extreme an event could potentially be. Both products give the likelihood of flash flood generating precipitation. For hurricane Harvey, 3-day EFI and SOT products for the period 26th - 29th August 2017 were used, generated from the twice daily, 18 km, 51 ensemble member ECMWF Integrated Forecast System. After regridding to 1 km resolution the forecasts were combined with vulnerable area data to produce a flash flood hazard risk area. The vulnerability data were floodplains (EU Joint Research Centre), road networks (Texas Department of Transport) and urban areas (Census Bureau geographic database), together reflecting the susceptibility to flash floods from the landscape. The flash flood hazard risk area forecasts were verified using a traditional approach against observed National Weather Service flash flood reports, a total of 153 reported flash floods have been detected in that period. Forecasts performed best for SOT = 5 (hit ratio = 65%, false alarm ratio = 44%) and EFI = 0.7 (hit ratio = 74%, false alarm ratio = 45%) at 72 h lead time. By including the vulnerable areas data, our verification results improved by 5-15%, demonstrating the value of vulnerability information within natural hazard forecasts. This research shows that flash flooding from hurricane Harvey was predictable up to 4 days ahead and that filtering the forecasts to vulnerable areas provides a more focused guidance to civil protection agencies planning their emergency response.
A LIS Validation Study at the KSC-ER using LDAR and Field Mill Data
NASA Technical Reports Server (NTRS)
Koshak, William J.; Christian, Hugh J.; Krider, E. Philip
1999-01-01
The chance of having the TRMM satellite pass over east central Florida when there is lightning over the NASA Kennedy Space Center (KSC) and USAF Eastern Range (ER) is small; however, such a condition did occur on September 21, 1998 (Day 264). Starting at about 20:40 GMT, the Lightning Imaging Sensor (LIS) reported 5 flashes during a 90 second interval that the KSC-ER was within the sensor field of view. Ground-based instrumentation, the Lightning Detection and Ranging (LDAR) system and a network of electric field mills (FM), detected 6 flashes in the same interval. In this paper, we will compare the times and locations of the optical pulses that were detected by LIS with the times and locations of RF sources (LDAR) and the charges that were deposited by the flash (FM network). We will show that LIS responded to all flashes that the LDAR and FM network detected; however, two discharges that were separated by less than 1 second in time and by about 10 km in space were grouped as one flash by the LIS data processing algorithm. In spite of the fact that all flashes occurred near the edge of the LIS field of view, the locations of the LIS events were consistent with both the LDAR and FM locations (the latter are usually within 1-2 kilometers of each other and often are co-located). Two of the 5 flashes reported by LIS were shifted north by about 8 km from the corresponding LDAR and FM locations. The LIS flash times tended to be after the first LDAR pulse was detected and before the last, and the integrated light signal (per LIS event) was surprisingly constant over the 5 flashes that were detected by LIS. In the future, we plan to study more correlated events and will try to determine whether and how the LIS light signal is related to the charge transfer in the flash and/or the number and spatial extent of RF sources.
NASA Astrophysics Data System (ADS)
Ait Moulay Larbi, E.; Bouley, S.; Dassou, A.; Benkhaldoun, Z.; Baratoux, D.; Lazrek, M.
2013-12-01
We present the research environment of our network. We highlight some results of the analysis of the first Lunar Meteorides impacts detected in Morocco. We present an exemple of ground-based instrumentation to carry out a successful search for lunar flashes phenomena. We also discuss the interest to monotoring these phenomena by focusing on the interest of determining the positions of the craters on the moon. The precise determination of impact flashes is very advantageous, especially in the near future there will be several new craters identified by LROC or other robotic spacecraft cameras. The two flashes reported in this study are optimally situated on central region of the lunar disk, which reduce the mismatch between the barycenter of radiation and the actual position of the impact. Smaller-scale lunar features are easily identified after superposition of a large number of images in order to increase the signal to noise ratio and produce an optimal image of the non-illuminated fraction of the moon. The sub-pixel shift of each image relative to the first frame (base frame) was determined by fitting the correlation peak obtained in the Fourier space to a 2- dimensional gaussian following Schaum and McHugh [1996]; Baratoux et al. [2001]. To increase further the positioning, the signal of the flash is is fitted to a 2-dimensional gaussian for each frame (previously shifted to the base image) where the flash is present. The barycenter of the flash is given as the rounded to the nearest integer of the average centers of the 2-dimensional gaussian functions. Two impact flashes are detected from AGM observatory in Marrakech, respectively on the February 6, 2013, at 06:29:56.7 UT and April 14, 2013, 20:00:45.4 UT. The characteristics of each flash are given in the table below. the diameter of the crater formed on the lunar surface can be estimated using Gault's formula for craters of less than 100 m in diameter, the results show that the meteoroids are likely producing craters of about 2.5 m and 4.4 m in diameter for Flash 1 and 2, respectively.Characteristics of lunar impact flashes
High Risk Flash Flood Rainstorm Mapping Based on Regional L-moments Approach
NASA Astrophysics Data System (ADS)
Ding, Hui; Liao, Yifan; Lin, Bingzhang
2017-04-01
Difficulties and complexities in elaborating flash flood early-warning and forecasting system prompt hydrologists to develop some techniques to substantially reduce the disastrous outcome of a flash flood in advance. An ideal to specify those areas that are subject at high risk to flash flood in terms of rainfall intensity in a relatively large region is proposed in this paper. It is accomplished through design of the High Risk Flash Flood Rainstorm Area (HRFFRA) based on statistical analysis of historical rainfall data, synoptic analysis of prevailing storm rainfalls as well as the field survey of historical flash flood events in the region. A HRFFRA is defined as the area potentially under hitting by higher intense-precipitation for a given duration with certain return period that may cause a flash flood disaster in the area. This paper has presented in detail the development of the HRFFRA through the application of the end-to-end Regional L-moments Approach (RLMA) to precipitation frequency analysis in combination with the technique of spatial interpolation in Jiangxi Province, South China Mainland. Among others, the concept of hydrometeorologically homogenous region, the precision of frequency analysis in terms of parameter estimation, the accuracy of quantiles in terms of uncertainties and the consistency adjustments of quantiles over durations and space, etc., have been addressed. At the end of this paper, the mapping of the HRFFRA and an internet-based visualized user-friendly data-server of the HRFFRA are also introduced. Key words: HRFFRA; Flash Flood; RLMA; rainfall intensity; Hydrometeorological homogenous region.
Figueiro, Mariana G.
2016-01-01
Background Light is most effective at changing the timing of the circadian clock when applied close to the core body temperature minimum. The present study investigated, in a home setting, if individually tailored light treatment using flashing blue light delivered through closed eyelids during the early part of the sleep period delayed circadian phase and sleep in a population of healthy older adults and in those suffering from early awakening insomnia. Methods Twenty-eight participants (9 early awakening insomniacs) completed an 8-week, within-subjects study. Twice, participants collected data during two baseline weeks and one intervention week. During the intervention week, participants wore a flashing blue (active) or a flashing red (control) light mask during sleep. Light was expected to delay circadian phase. Saliva samples for dim light melatonin onset (DLMO) were collected at the end of each baseline and intervention week. Wrist actigraphy and Daysimeter, a calibrated light and activity meter, data were collected during the entire study. Results Compared to baseline, flashing blue light, but not flashing red light, significantly (p<0.05) delayed DLMO. The mean ± standard deviation phase shift (minutes) was 0:06 ± 0:30 for the flashing red light and 0:34 ± 0:30 for the flashing blue light. Compared to Day 1, sleep start times were significantly delayed (by approximately 46 minutes) at Day 7 after the flashing blue light. The light intervention did not affect sleep efficiency. Conclusions The present study demonstrated the feasibility of using light through closed eyelids during sleep for promoting circadian alignment and sleep health. PMID:26985450
Huicochea-Gómez, Laura; Sievert, Lynnette Leidy; Cahuich-Campos, Diana; Brown, Daniel E
2017-01-01
The purpose of this study was to better understand the experience of calores (hot flashes) in the state of Campeche, Mexico, and characteristics of women's lives. This study was carried out to understand the sociocultural context of women's lives before conducting a larger semistructured survey in the same communities. Eighty-five women from rural and urban settings participated in open-ended interviews about the menopausal transition, with particular attention to hot flashes. Univariate and logistic regression analyses identified potential determinants of hot flashes. Qualitative responses were analyzed for central themes from the 40 women who experienced "calores" associated with menopause at the time of interview. The word "calores" was used to describe a variety of sensations and experiences related to the hot climate, infections, going in and out of air-conditioning, emotional stress, and physical exertion, as well as the symptom associated with menopause. In quantitative analyses, the likelihood of experiencing hot flashes varied by menopause status and rural/urban residence. In qualitative analyses, themes that characterized the lives of women with hot flashes were as follows: the search for, and the availability of, biomedical care; presence or absence of networks of social support; marital status and quality of the relationship; and occupational stress. Hot flash questionnaires can elicit different symptom frequencies depending on the language used and the sociocultural context of women's lives. Qualitative findings suggest that the themes most likely to influence the perception and experience of hot flashes in Campeche are biomedicine, social support, marriage, and stress.
Menopausal hot flashes and insulin resistance.
Tuomikoski, Pauliina; Ylikorkala, Olavi; Mikkola, Tomi S
2012-10-01
Recent data have indicated that menopausal hot flashes may be a determinant for cardiovascular health. Therefore, we studied the impact of hot flashes on insulin resistance, one of the most powerful markers of cardiovascular health, in recently postmenopausal women. We studied 143 recently postmenopausal (amenorrhea 6-36 mo) healthy and normal-weight women without previous hormone therapy use. The women prospectively recorded the number and severity of hot flashes for 2 weeks, and a validated total symptom score, the hot flash weekly weighted score, was calculated for each woman. Insulin resistance was assessed from fasting blood levels of glucose and insulin with the homeostasis model assessment. In 12 women, the assessment of insulin (n = 11) or glucose (n = 1) failed, and they were excluded from further analysis. Thus, hot flashes were absent in 19, mild in 32, moderate in 27, and severe in 53 women. The levels of glucose or insulin, or HOMA showed no differences between these groups, nor was insulin resistance related to the number or severity of hot flashes or to the levels of C-reactive protein or sex hormone-binding globulin. Overall, insulin resistance showed a positive association with body mass index (mean difference, 0.058; 95% CI, 0.015-0.102; P = 0.009) and a negative association with level of estradiol (mean difference, -0.002; 95% CI, -0.003 to -0.001; P = 0.009). Insulin resistance may not be involved in hot flash-related changes in cardiovascular health. However, because of the small sample size, these findings need to be interpreted with caution.
Excitation and desensitization of mouse rod photoreceptors in vivo following bright adapting light
Kang Derwent, Jennifer J; Qtaishat, Nasser M; Pepperberg, David R
2002-01-01
Electroretinographic (ERG) methods were used to determine response properties of mouse rod photoreceptors in vivo following adapting illumination that produced a significant extent of rhodopsin bleaching. Bleaching levels prevailing at ∼10 min and ∼20 min after the adapting exposure were on average 14% and 9%, respectively, based on the analysis of visual cycle retinoids in the eye tissues. Recovery of the rod response to the adapting light was monitored by analysing the ERG a-wave response to a bright probe flash presented at varying times during dark adaptation. A paired-flash procedure, in which the probe flash was presented at defined times after a weak test flash of fixed strength, was used to determine sensitivity of the rod response to the test flash. Recovery of the response to the adapting light was 80% complete at 13.5 ± 3.0 min (mean ± s.d.; n = 7) after adapting light offset. The adapting light caused prolonged desensitization of the weak-flash response derived from paired-flash data. By comparison with results obtained in the absence of the adapting exposure, desensitization determined with a test-probe interval of 80 ms was ∼fourfold after 5 min of dark adaptation and ∼twofold after 20 min. The results indicate, for mouse rods in vivo, that the time scale for recovery of weak-flash sensitivity substantially exceeds that for the recovery of circulating current following significant rhodopsin bleaching. The lingering desensitization may reflect a reduced efficiency of signal transmission in the phototransduction cascade distinct from that due to residual excitation. PMID:12015430
A study on flash sintering and related phenomena in titania and its composite with alumina
NASA Astrophysics Data System (ADS)
Shikhar
In 2010, Cologna et. al. [1] reported that with a help of small electric field 120 Vcm-1, the sintering temperature of 3 mol % yittria stabilized zirconia could be brought down to 850°C from 1450°C. On top of reducing the temperature requirements, the green sample could be sintered from starting density of 50% to near full density in mere 5 seconds, a sintering rate three orders of magnitude higher than conventional methods. This discovery led to the emergence of a new field of enhanced sintering with electric field, named "Flash Sintering". The objective of this thesis is to understand the phenomenological behavior of flash-sintering and related phenomena on titania and its composites with alumina at elevated temperature. The possible mechanisms to explain flash sintering are discussed: Joule heating and the avalanche of defect generation [2], both induced by the rapid rise in conductivity just before the onset of the flash. Apparently, both mechanisms play a role. The thesis covers the response of pure titania and composites of titania-alumina under flash and compared with conventional sintering. We start with the sintering behavior of pure titania and observe lowering of sintering temperature requirements with higher applied electric field. The conductivity of titania during flash is also measured, and compared with the nominal conductivity of titania at equivalent temperatures. The conductivity during flash is determined to be have a different activation energy. For the composites of titania-alumina, effect of flash on the constrained sintering was studied. It is a known fact that sintering of one component of composite slows down when the other component of a different densification rate is added to it, called constrained sintering. In our case, large inclusions of alumina particles were added to nano-grained titania green compact that hindered its densification. Flash sintering was found to be overcoming this problem and near full densification was achieved. In another experiment, effect of high current density and hold time under flash on the chemical reaction (phase transformation) of titania and alumina to form Al2TiO5 is studied. It was found that not only flash enhances the kinetics of reaction when compared with conventional heating at equivalent temperatures, but also brought down the phase transformation temperature for this spinel formation, as reported by the phase diagram. In-situ X-ray diffraction experiments were performed at the synchrotron facility in Argonne National Laboratory. The specimen temperature were measured during the experiment on the basis of peak shift with temperature and were found to be matching with our predicted values by Black-Body-Radiation model. We also observed the instant evolution of texture in grain orientation of pure titania under flash and their disappearance as the fields were switched off. Study on chemical kinetics between titania and alumina were also performed which supported our findings of in-house experiments.
A Modern Apparatus for Performing Flash Chromatography: An Experiment for the Organic Laboratory
ERIC Educational Resources Information Center
Naumiec, Gregory R.; Del Padre, Angela N.; Hooper, Matthew M.; Germaine, Alison St.; DeBoef, Brenton
2013-01-01
A modern apparatus for performing flash chromatography using commercially available, prepacked silica cartridges has been developed. The key advantage of this system, when compared to traditional flash chromatography, is its use of commercially available silica cartridges, which obviates the need for students to handle silica gel. The apparatus…
2005-12-01
hot flashes on sleep, fatigue, and quality of life , and compare the accuracy of alternative means of assessing hot flashes. The overarching goal is to...diverse applications. Results will have implications for the education of oncologists with respect to quality of life issues in prostate cancer, set
2005-01-01
of hot flashes on sleep, fatigue, and quality of life , and compare the accuracy of alternative means of assessing hot flashes. The overarching goal is...diverse applications. Results will have implications for the education of oncologists with respect to quality of life issues in prostate cancer, set
Software Tools for Stochastic Simulations of Turbulence
2015-08-28
client interface to FTI. Specefic client programs using this interface include the weather forecasting code WRF ; the high energy physics code, FLASH...client programs using this interface include the weather forecasting code WRF ; the high energy physics code, FLASH; and two locally constructed fluid...45 4.4.2.2 FLASH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 4.4.2.3 WRF
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-25
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-683] In the Matter of Certain MLC Flash Memory Devices and Products Containing Same; Notice of Commission Determination Not To Review an Initial... the United States after importation of certain MLC flash memory devices and products containing same...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-13
... INTERNATIONAL TRADE COMMISSION [Docket No 2971] Certain Flash Memory Chips and Products Containing the Same Correction to Notice of Receipt of Complaint; Solicitation of Comments Relating to the Public..., Certain Flash Memory Chips and Products Containing the Same, DN 2971; the Commission solicited comments on...
Behavioral Treatment of Menopausal Hot Flashes: Evaluation by Objective Methods.
ERIC Educational Resources Information Center
Germaine, Leonard M.; Freedman, Robert R.
1984-01-01
Used latency to hot flash onset under heat stress to evaluate the effects of relaxation treatment or a control procedure in 14 menopausal women. Following treatment, the latency to hot flash onset during heat stress was increased in relaxation subjects. Reported symptom frequency was significantly reduced in relaxation subjects. (BH)
Propoxur is a widely used N-methyl carbamate pesticide that acts by inhibiting cholinesterases (ChE), which may lead to cholinergic toxicity. Flash evoked potentials (FEPs) are a neurophysiological response following stimulation of the visual system with flashes of light. They ar...
Macromedia Flash as a Tool for Mathematics Teaching and Learning
ERIC Educational Resources Information Center
Garofalo, Joe; Summers, Tim
2004-01-01
Macromedia Flash is a powerful and robust development tool. Because of its graphical, sound, and animation capabilities (and ubiquitous browser plug-in), major companies employ it in their website development (see www.nike.com or www.espn.com). These same features also make Flash a valuable environment for building multi-representational "movies"…
Conformational detection of p53's oligomeric state by FlAsH Fluorescence.
Webber, Tawnya M; Allen, Andrew C; Ma, Wai Kit; Molloy, Rhett G; Kettelkamp, Charisse N; Dow, Caitlin A; Gage, Matthew J
2009-06-19
The p53 tumor suppressor protein is a critical checkpoint in prevention of tumor formation, and the function of p53 is dependent on proper formation of the active tetramer. In vitro studies have shown that p53 binds DNA most efficiently as a tetramer, though inactive p53 is predicted to be monomeric in vivo. We demonstrate that FlAsH binding can be used to distinguish between oligomeric states of p53, providing a potential tool to explore p53 oligomerization in vivo. The FlAsH tetra-cysteine binding motif has been incorporated along the dimer and tetramer interfaces in the p53 tetramerization domain to create reporters for the dimeric and tetrameric states of p53, though the geometry of the four cysteines is critical for efficient FlAsH binding. Furthermore, we demonstrate that FlAsH binding can be used to monitor tetramer formation in real-time. These results demonstrate the potential for using FlAsH fluorescence to monitor protein-protein interactions in vivo.
Conformational detection of p53's oligomeric state by FlAsH Fluorescence
Webber, Tawnya M.; Allen, Andrew C.; Ma, Wai Kit; Molloy, Rhett G.; Kettelkamp, Charisse N.; Dow, Caitlin A.; Gage, Matthew J.
2009-01-01
The p53 tumor suppressor protein is a critical checkpoint in prevention of tumor formation, and the function of p53 is dependent on proper formation of the active tetramer. In vitro studies have shown that p53 binds DNA most efficiently as a tetramer, though inactive p53 is predicted to be monomeric in vivo. We demonstrate that FlAsH binding can be used to distinguish between oligomeric states of p53, providing a potential tool to explore p53 oligomerization in vivo. The FlAsH tetra-cysteine binding motif has been incorporated along the dimer and tetramer interfaces in the p53 tetramerization domain to create reporters for the dimeric and tetrameric states of p53, though the geometry of the four cysteines is critical for efficient FlAsH binding. Furthermore, we demonstrate that FlAsH binding can be used to monitor tetramer formation in real-time. These results demonstrate the potential for using FlAsH fluorescence to monitor protein-protein interactions in vivo. PMID:19393630
The Origin of the Optical Flashes: The Case Study of GRB 080319B and GRB 130427A
NASA Astrophysics Data System (ADS)
Fraija, N.; Veres, P.
2018-05-01
Correlations between optical flashes and gamma-ray emissions in gamma-ray bursts (GRBs) have been searched in order to clarify the question of whether these emissions occur at internal and/or external shocks. Among the most powerful GRBs ever recorded are GRB 080319B and GRB 130427A, which at early phases presented bright optical flashes possibly correlated with γ-ray components. Additionally, both bursts were fortuitously located within the field of view of the TeV γ-ray Milagro and HAWC observatories, and although no statistically significant excess of counts were collected, upper limits were placed on the GeV–TeV emission. Considering the synchrotron self-Compton emission from internal shocks and requiring the GeV–TeV upper limits, we found that the optical flashes and the γ-ray components are produced by different electron populations. Analyzing the optical flashes together with the multiwavelength afterglow observation, we found that these flashes can be interpreted in the framework of the synchrotron reverse shock model when outflows have arbitrary magnetizations.
Flash Inactivation of Oxygen Evolution
Frasch, Wayne D.; Cheniae, George M.
1980-01-01
Brief saturating light flashes were used to probe the mechanism of inactivation of O2 evolution by Tris in chloroplasts. Maximum inactivation with a single flash and an oscillation with period of four on subsequent flashes was observed. Analyses of the oscillations suggested that only the charge-collecting O2-evolving catalyst of photosystem II (S2-state) was a target of inactivation by Tris. This conclusion was supported by the following observations: (a) hydroxylamine preequilibration caused a three-flash delay in the inactivation pattern; (b) the lifetimes of the Tris-inactivable and S2-states were similar; and (c) reagents accelerating S2 deactivation decreased the lifetime of the inactivable state. Inactivation proved to be moderated by F, the precursor of Signal IIs, as shown by a one flash delay with chloroplasts having high abundance of F. Evidence was obtained for cooperativity effects in inactivation and NH3 was shown to be a competitive inhibitor of the Tris-induced inactivation. S2-dependent inactivation was inhibited by glutaraldehyde fixation of chloroplasts, possibly suggesting that inactivation proceeds via conformational changes of the S2-state. PMID:16661270
Additions and improvements to the high energy density physics capabilities in the FLASH code
NASA Astrophysics Data System (ADS)
Lamb, D. Q.; Flocke, N.; Graziani, C.; Tzeferacos, P.; Weide, K.
2016-10-01
FLASH is an open source, finite-volume Eulerian, spatially adaptive radiation magnetohydrodynamics code that has the capabilities to treat a broad range of physical processes. FLASH performs well on a wide range of computer architectures, and has a broad user base. Extensive high energy density physics (HEDP) capabilities have been added to FLASH to make it an open toolset for the academic HEDP community. We summarize these capabilities, emphasizing recent additions and improvements. In particular, we showcase the ability of FLASH to simulate the Faraday Rotation Measure produced by the presence of magnetic fields; and proton radiography, proton self-emission, and Thomson scattering diagnostics with and without the presence of magnetic fields. We also describe several collaborations with the academic HEDP community in which FLASH simulations were used to design and interpret HEDP experiments. This work was supported in part at the University of Chicago by the DOE NNSA ASC through the Argonne Institute for Computing in Science under field work proposal 57789; and the NSF under Grant PHY-0903997.
Multi-Level Bitmap Indexes for Flash Memory Storage
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Kesheng; Madduri, Kamesh; Canon, Shane
2010-07-23
Due to their low access latency, high read speed, and power-efficient operation, flash memory storage devices are rapidly emerging as an attractive alternative to traditional magnetic storage devices. However, tests show that the most efficient indexing methods are not able to take advantage of the flash memory storage devices. In this paper, we present a set of multi-level bitmap indexes that can effectively take advantage of flash storage devices. These indexing methods use coarsely binned indexes to answer queries approximately, and then use finely binned indexes to refine the answers. Our new methods read significantly lower volumes of data atmore » the expense of an increased disk access count, thus taking full advantage of the improved read speed and low access latency of flash devices. To demonstrate the advantage of these new indexes, we measure their performance on a number of storage systems using a standard data warehousing benchmark called the Set Query Benchmark. We observe that multi-level strategies on flash drives are up to 3 times faster than traditional indexing strategies on magnetic disk drives.« less
Wide Bandgap Semiconductor Detector Optimization for Flash X-Ray Measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roecker, Caleb Daniel; Schirato, Richard C.
2017-11-17
Charge trapping, resulting in a decreased and spatially dependent electric field, has long been a concern for wide bandgap semiconductor detectors. While significant work has been performed to characterize this degradation at varying temperatures and radiation environments, this work concentrates upon examining the event-to-event response in a flash X-ray environment. The following work investigates if charge trapping is a problem for CZT detectors, with particular emphasis on flash X-ray radiation fields at cold temperatures. Results are compared to a non-flash radiation field, using an Am-241 alpha source and similar temperature transitions. Our ability to determine if a response change occurredmore » was hampered by the repeatability of our flash X-ray systems; a small response change was observed with the Am-241 source. Due to contrast of these results, we are in the process of revisiting the Am-241 measurements in the presence of a high radiation environment. If the response change is more pronounced in the high radiation environment, a similar test will be performed in the flash X-ray environment.« less
Regional reconstruction of flash flood history in the Guadarrama range (Central System, Spain).
Rodriguez-Morata, C; Ballesteros-Cánovas, J A; Trappmann, D; Beniston, M; Stoffel, M
2016-04-15
Flash floods are a common natural hazard in Mediterranean mountain environments and responsible for serious economic and human disasters. The study of flash flood dynamics and their triggers is a key issue; however, the retrieval of historical data is often limited in mountain regions as a result of short time series and the systematic lack of historical data. In this study, we attempt to overcome data deficiency by supplementing existing records with dendrogeomorphic techniques which were employed in seven mountain streams along the northern slopes of the Guadarrama Mountain range. Here we present results derived from the tree-ring analysis of 117 samples from 63 Pinus sylvestris L. trees injured by flash floods, to complement existing flash flood records covering the last ~200years and comment on their hydro-meteorological triggers. To understand the varying number of reconstructed flash flood events in each of the catchments, we also performed a comparative analysis of geomorphic catchment characteristics, land use evolution and forest management. Furthermore, we discuss the limitations of dendrogeomorphic techniques applied in managed forests. Copyright © 2016 Elsevier B.V. All rights reserved.
Environmental Effects on Data Retention in Flash Cells
NASA Technical Reports Server (NTRS)
Katz, Rich; Flowers, David; Bergevin, Keith
2017-01-01
Flash technology is being utilized in fuzed munition applications and, based on the development of digital logic devices in the commercial world, usage of flash technology will increase. Antifuse technology, prevalent in non-volatile field programmable gate arrays (FPGAs), will eventually be phased out as new devices have not been developed for approximately a decade. The reliance on flash technology presents a long-term reliability issue for both DoD and NASA safety- and mission-critical applications. A thorough understanding of the data retention failure modes and statistics associated with Flash data retention is of vital concern to the fuze safety community. A key retention parameter for a flash cell is the threshold voltage (VTH), which is an indirect indicator of the amount of charge stored on the cells floating gate. This paper will present the results of our on-going tests: long-term storage at 150 C for a small population of devices, neutron radiation exposure, electrostatic discharge (ESD) testing, and the trends of large populations (over 300 devices for each condition) exposed to three difference temperatures: 25 C, 125 C, and 150 C.
The efficacy of Iranian herbal medicines in alleviating hot flashes: A systematic review
Ghazanfarpour, Masumeh; Sadeghi, Ramin; Abdolahian, Somayeh; Latifnejad Roudsari, Robab
2016-01-01
Background: Hot flashes are the most common symptoms experienced by women around the time of menopause. Many women are interested in herbal medicines because of fear of side effects of hormone therapy. Objective: The aim of this systematic review was to assess the effectiveness of Iranian herbal medicines in alleviating hot flashes. Materials and Methods: MEDLINE (1966 to January 2015), Scopus (1996 to January 2015), and Cochrane Central Register of Controlled Trials (The Cochrane Library, issue 1, 2015) were searched along with, SID, Iran Medex, Magiran, Medlib and Irandoc. Nineteen randomized controlled trials met the inclusion criteria. Results: Overall, studies showed that Anise (Pimpinella anisum), licorice (Glycyrrhizaglabra), Soy, Black cohosh, Red clover, Evening primrose, Flaxseed, Salvia officinalis, Passiflora، itex Agnus Castus, Piascledine (Avacado plus soybean oil), St. John's wort (Hypericum perforatum), and valerian can alleviate the side effects of hot flashes. Conclusion: This research demonstrated the efficacy of herbal medicines in alleviating hot flashes, which are embraced both with people and health providers of Iran Therefore, herbal medicine can be seen as an alternative treatment for women experiencing hot flashes. PMID:27294213
Risk Factors, Pathophysiology, and Treatment of Hot Flashes in Cancer
Fisher, William I.; Johnson, Aimee K.; Elkins, Gary R.; Otte, Julie L.; Burns, Debra S.; Yu, Menggang; Carpenter, Janet S.
2012-01-01
Hot flashes are prevalent and severe symptoms that can interfere with mood, sleep, and quality of life for women and men with cancer. The purpose of this article is to review existing literature on the risk factors, pathophysiology, and treatment of hot flashes in persons with cancer. Electronic searches were conducted to identify relevant, English-language literature published through June 15, 2012. Results indicated that risk factors for hot flashes in cancer include patient-related factors (eg, age, race/ethnicity, educational level, smoking history, cardiovascular risk including BMI, and genetics) and disease-related factors (eg, cancer diagnosis, and dose/type of treatment). In addition, although the pathophysiology of hot flashes has remained elusive, these symptoms are likely attributable to disruptions in thermoregulation and neurochemicals. Therapies that have been offered or tested fall into 4 broad categories: pharmacological, nutraceutical, surgical, and complementary/behavioral strategies. The evidence base for this broad range of therapies varies, with some treatments not yet having been fully tested or showing equivocal results. The evidence base surrounding all therapies is evaluated to enhance hot flash treatment decision making by clinicians and patients. PMID:23355109
Variation of a Lightning NOx Indicator for National Climate Assessment
NASA Technical Reports Server (NTRS)
Koshak, W. J.; Vant-Hull, B.; McCaul, E. W.; Peterson, H. S.
2014-01-01
In support of the National Climate Assessment (NCA) program, satellite Lightning Imaging Sensor (LIS) data is used to estimate lightning nitrogen oxides (LNOx) production over the southern portion of the conterminous US. The total energy of each flash is estimated by analyzing the LIS optical event data associated with each flash (i.e., event radiance, event footprint area, and derivable event range). The LIS detects an extremely small fraction of the total flash energy; this fraction is assumed to be constant apart from the variability associated with the flash optical energy detected across the narrow (0.909 nm) LIS band. The estimate of total energy from each flash is converted to moles of LNOx production by assuming a chemical yield of 10(17) molecules Joule(-1). The LIS-inferred variable LNOx production from each flash is summed to obtain total LNOx production, and then appropriately enhanced to account for LIS detection efficiency and LIS view time. Annual geographical plots and time series of LNOx production are provided for a 16 year period (1998-2013).
NASA Astrophysics Data System (ADS)
Sakaki, Yukiya; Yamada, Tomoaki; Matsui, Chihiro; Yamaga, Yusuke; Takeuchi, Ken
2018-04-01
In order to improve performance of solid-state drives (SSDs), hybrid SSDs have been proposed. Hybrid SSDs consist of more than two types of NAND flash memories or NAND flash memories and storage-class memories (SCMs). However, the cost of hybrid SSDs adopting SCMs is more expensive than that of NAND flash only SSDs because of the high bit cost of SCMs. This paper proposes unique hybrid SSDs with two-dimensional (2D) horizontal multi-level cell (MLC)/three-dimensional (3D) vertical triple-level cell (TLC) NAND flash memories to achieve higher cost-performance. The 2D-MLC/3D-TLC hybrid SSD achieves up to 31% higher performance than the conventional 2D-MLC/2D-TLC hybrid SSD. The factors of different performance between the proposed hybrid SSD and the conventional hybrid SSD are analyzed by changing its block size, read/write/erase latencies, and write unit of 3D-TLC NAND flash memory, by means of a transaction-level modeling simulator.
Flash photolysis of rhodopsin in the cat retina
1981-01-01
The bleaching of rhodopsin by short-duration flashes of a xenon discharge lamp was studied in vivo in the cat retina with the aid of a rapid, spectral-scan fundus reflectometer. Difference spectra recorded over a broad range of intensities showed that the bleaching efficacy of high-intensity flashes was less than that of longer duration, steady lights delivering the same amount of energy. Both the empirical results and those derived from a theoretical analysis of flash photolysis indicate that, under the conditions of these experiments, the upper limit of the flash bleaching of rhodopsin in cat is approximately 90%. Although the fact that a full bleach could not be attained is attributable to photoreversal, i.e., the photic regeneration of rhodopsin from its light-sensitive intermediates, the 90% limit is considerably higher than the 50% (or lower) value obtained under other experimental circumstances. Thus, it appears that the duration (approximately 1 ms) and spectral composition of the flash, coupled with the kinetic parameters of the thermal and photic reactions in the cat retina, reduce the light-induced regeneration of rhodopsin to approximately 10%. PMID:7252476
Greene, Ernest; Ogden, R. Todd
2013-01-01
Shape patterns were displayed with simultaneous brief flashes from a light-emitting diode array. Flash durations in the microsecond range and luminous intensities were adjusted to vary the degree of successful shape recognition. Four experiments were conducted to test whether Bloch's law would apply in this task. Bloch's law holds that for very brief flashes the perceptual threshold is determined by the total number of photons being delivered, i.e., there is reciprocity of intensity and duration. The present results did not find that effectiveness of flashes was based on the total quantity of photons, as predicted by Bloch's law. Additionally, the evidence points to a visual mechanism that has ultra-high temporal precision that either registers the rate of photon flux or the duration of flashes. PMID:24349700
The Behavior of Total Lightning Activity in Severe Florida Thunderstorms
NASA Technical Reports Server (NTRS)
Williams, Earle; Boldi, Bob; Matlin, Anne; Weber, Mark; Hodanish, Steve; Sharp, Dave; Goodman, Steve; Raghavan, Ravi; Buechler, Dennis
1998-01-01
The development of a new observational system called LISDAD (Lightning Imaging Sensor Demonstration and Display) has enabled a study of severe weather in central Florida. The total flash rates for storms verified to be severe are found to exceed 60 flashes/min, with some values reaching 500 flashes/min. Similar to earlier results for thunderstorm microbursts, the peak flash rate precedes the severe weather at the ground by 5-20 minutes. A distinguishing feature of severe storms is the presence of lightning "jumps"-abrupt increases in flash rate in advance of the maximum rate for the storm. ne systematic total lightning precursor to severe weather of all kinds-wind, hail, tornadoes-is interpreted in terms of the updraft that sows the seeds aloft for severe weather at the surface and simultaneously stimulates the ice microphysics that drives the lightning activity.
Flash Extraction and Physicochemical Characterization of Oil from Elaeagnus mollis Diels Seeds.
Kan, Lina; Wang, Lin; Ding, Qingzhen; Wu, Yanwen; Ouyang, Jie
2017-04-03
A flash extraction method was used to isolate Elaeagnus mollis oil (EMO). The optimal extraction parameters, sample/solvent ratio and extraction temperature, were determined to be 1:10 (g/mL) and 40°C, respectively. Especially, the extraction yield reached 49.30% when the extraction time was as short as 2 min. No obvious difference was observed in fatty acid composition, iodine value, saponification number, total phenolic content and tocopherol content between flash-extracted EMO and Soxhlet-extracted EMO, but their physicochemical values were lower than those of cold-pressed EMO. Cold-pressed EMO had higher oxidation stability, DPPH (1-diphenyl-2-picrylhydrazyl) and hydroxyl radical-scavenging activities than flash-extracted EMO and Soxlet extracted EMO. The flash extraction is demonstrated to be an alternative, efficient method for the vegetable oil production.
Quasi-steady-state analysis of coupled flashing ratchets.
Levien, Ethan; Bressloff, Paul C
2015-10-01
We perform a quasi-steady-state (QSS) reduction of a flashing ratchet to obtain a Brownian particle in an effective potential. The resulting system is analytically tractable and yet preserves essential dynamical features of the full model. We first use the QSS reduction to derive an explicit expression for the velocity of a simple two-state flashing ratchet. In particular, we determine the relationship between perturbations from detailed balance, which are encoded in the transitions rates of the flashing ratchet, and a tilted-periodic potential. We then perform a QSS analysis of a pair of elastically coupled flashing ratchets, which reduces to a Brownian particle moving in a two-dimensional vector field. We suggest that the fixed points of this vector field accurately approximate the metastable spatial locations of the coupled ratchets, which are, in general, impossible to identify from the full system.
Variability of lightning activity over India on ENSO time scales
NASA Astrophysics Data System (ADS)
Ahmad, Adnan; Ghosh, Mili
2017-12-01
ENSO, the reliable indicator of inter-annual climate variation of the ocean-atmosphere system in the tropical Pacific region, can affect the overall lightning activity which is another atmospheric phenomenon. In the present study, the impact of the ENSO on the total lightning activity over India has been studied for the period 2004-2014. During the El-Nino period (July 2004-April 2005 and July 2009-April 2010), total number of lightning flashes increased by 10% and 18% respectively and during La-Nina period (July 2010-April 2011 and August 2011 to March 2012), the total number of lightning flashes decreased approximately by 19% and 28% respectively as compared to the mean of corresponding period (2004-14) of the Non-ENSO. Seasonal variation of flash density is also examined for the El-Nino and La-Nina period. The result shows that in the El-Nino period of the pre-monsoon and monsoon seasons, there is an increment in the flash density approximately by 48% and 9% respectively than the Non-ENSO and the spatial variation also having high flash density along the foot of Himalayas region. In the post-monsoon season, there is a marginal change in the flash density between El-Nino and the Non-ENSO. In the winter season, there is an increment in flash density in the El-Nino period approximately by 45% than the Non-ENSO. In the La-Nina period of the pre-monsoon and monsoon seasons, there is the decrement in the flash density approximately by the 44% and 24% respectively than the Non-ENSO. In the Post-monsoon season and winter season of La-Nina, the flash density is increased by about 24% and 33% over India. These findings can be applied to do proper planning of lightning induced hazard mitigation as lightning is of one of the major natural disasters of India.
Inversions of synthetic umbral flashes: Effects of scanning time on the inferred atmospheres
NASA Astrophysics Data System (ADS)
Felipe, T.; Socas-Navarro, H.; Przybylski, D.
2018-06-01
Context. The use of instruments that record narrowband images at selected wavelengths is a common approach in solar observations. They allow scanning of a spectral line by sampling the Stokes profiles with two-dimensional images at each line position, but require a compromise between spectral resolution and temporal cadence. The interpretation and inversion of spectropolarimetric data generally neglect changes in the solar atmosphere during the scanning of line profiles. Aims: We evaluate the impact of the time-dependent acquisition of various wavelengths on the inversion of spectropolarimetric profiles from chromospheric lines during umbral flashes. Methods: Numerical simulations of nonlinear wave propagation in a sunspot model were performed with the code MANCHA. Synthetic Stokes parameters in the Ca II 8542 Å line in NLTE were computed for an umbral flash event using the code NICOLE. Artificial profiles with the same wavelength coverage and temporal cadence from reported observations were constructed and inverted. The inferred atmospheric stratifications were compared with the original simulated models. Results: The inferred atmospheres provide a reasonable characterization of the thermodynamic properties of the atmosphere during most of the phases of the umbral flash. The Stokes profiles present apparent wavelength shifts and other spurious deformations at the early stages of the flash, when the shock wave reaches the formation height of the Ca II 8542 Å line. These features are misinterpreted by the inversion code, which can return unrealistic atmospheric models from a good fit of the Stokes profiles. The misguided results include flashed atmospheres with strong downflows, even though the simulation exhibits upflows during the umbral flash, and large variations in the magnetic field strength. Conclusions: Our analyses validate the inversion of Stokes profiles acquired by sequentially scanning certain selected wavelengths of a line profile, even in the case of rapidly changing chromospheric events such as umbral flashes. However, the inversion results are unreliable during a short period at the development phase of the flash.
Moreno-Fernandez, Jesus; Pazos-Couselo, Marcos; González-Rodriguez, Maria; Rozas, Pedro; Delgado, Manuel; Aguirre, Miguel; Garcia-Lopez, Jose Manuel
2018-06-12
To analyze the clinical impact of the Flash glucose monitoring system in patients with type 1 diabetes mellitus (T1DM) treated with continuous subcutaneous insulin infusion (CSII). A 24-week retrospective cohort study in CSII-treated T1DM patients exposed (1:1) to the Flash glucose monitoring system vs. self-monitoring of capillary blood glucose (SMBG). The primary outcome was the difference in hemoglobin A1c (HbA1c) levels between both groups at the end of the study. Thirty-six patients with a mean age of 38.2 years (range 22-55) and a mean T1DM duration of 20.9±7.8 years, treated with CSII for 7.1±5.4 years, were enrolled into the study. At the end of the study, mean HbA1c levels improved in patients in the Flash group (7.1±0.7 vs. 7.8±1.0, p=0.04). Only the Flash group showed a significant decrease in HbA1c levels of -0.4% (95% CI, -0.6, -0.2; p=0.004) during follow-up. Flash patients captured 93.9% of data through 17.8±9.9 scans daily. In fact, the Flash cohort showed a three-fold increase in daily self-monitoring of glucose, while daily frequency of SMBG decreased during the study (-1.8 tests/24h (95% CI -3, -0.7; p=0.01). No safety issues related to Flash use were recorded. The Flash glucose monitoring system is a novel approach to improve blood glucose control in CSII-treated T1DM patients. Randomized controlled trials are needed to assess the effectiveness of this system in CSII-treated T1DM patients. Copyright © 2018 SEEN y SED. Publicado por Elsevier España, S.L.U. All rights reserved.
Bordeleau, Louise; Pritchard, Kathleen; Goodwin, Pamela; Loprinzi, Charles
2007-02-01
Women with breast cancer may experience treatment-induced menopausal symptoms or natural menopause. Menopausal symptoms, particularly hot flashes, are reported at a high frequency in this group and tend to be more severe, distressing, and of greater duration than in controls. Because of the contribution of sex hormones to breast cancer, the use of hormonal agents for the control of hot flashes is problematic in these women. Safer nonhormonal alternatives are recommended for this patient group. This was a systematic review of the therapeutic options for the treatment of hot flashes in breast cancer survivors. MEDLINE was searched from 1990 to July 2006 using the disease-specific term breast neoplasms and the subheadings menopause and hot flashes. EMBASE was searched from 1990 to March 2006 using the disease-specific subject headings breast tumor/ breast cancer and menopause and the key word hot flashes. The reference lists of the identified articles and relevant review articles were examined for additional publications. Pertinent articles and abstracts of large randomized controlled trials focusing on the treatment of hot flashes in breast cancer survivors were selected for review. Pilot studies were excluded. A number of nonpharmacologic approaches are available for the treatment of hot flashes in breast cancer survivors, although they appear to be of limited effectiveness. Complementary alternative medicine therapies and vitamin E have been found to have modest effectiveness at best, and data on their long-term safety are not available. Centrally active agents such as the antidepressants venlafaxine and paroxetine and the anti seizure agent gabapentin have shown clinical effectiveness and appear to be reasonably well tolerated in this population. Centrally active agents (eg, venlafaxine, paroxetine, gabapentin) are regarded as the most promising nonhormonal treatments for hot flashes in breast cancer survivors. Nonpharmacologic and complementary alternative medicine therapies have limited effectiveness.
Economic assessment of flash co-pyrolysis of short rotation coppice and biopolymer waste streams.
Kuppens, T; Cornelissen, T; Carleer, R; Yperman, J; Schreurs, S; Jans, M; Thewys, T
2010-12-01
The disposal problem associated with phytoextraction of farmland polluted with heavy metals by means of willow requires a biomass conversion technique which meets both ecological and economical needs. Combustion and gasification of willow require special and costly flue gas treatment to avoid re-emission of the metals in the atmosphere, whereas flash pyrolysis mainly results in the production of (almost) metal free bio-oil with a relatively high water content. Flash co-pyrolysis of biomass and waste of biopolymers synergistically improves the characteristics of the pyrolysis process: e.g. reduction of the water content of the bio-oil, more bio-oil and less char production and an increase of the HHV of the oil. This research paper investigates the economic consequences of the synergistic effects of flash co-pyrolysis of 1:1 w/w ratio blends of willow and different biopolymer waste streams via cost-benefit analysis and Monte Carlo simulations taking into account uncertainties. In all cases economic opportunities of flash co-pyrolysis of biomass with biopolymer waste are improved compared to flash pyrolysis of pure willow. Of all the biopolymers under investigation, polyhydroxybutyrate (PHB) is the most promising, followed by Eastar, Biopearls, potato starch, polylactic acid (PLA), corn starch and Solanyl in order of decreasing profits. Taking into account uncertainties, flash co-pyrolysis is expected to be cheaper than composting biopolymer waste streams, except for corn starch. If uncertainty increases, composting also becomes more interesting than flash co-pyrolysis for waste of Solanyl. If the investment expenditure is 15% higher in practice than estimated, the preference for flash co-pyrolysis compared to composting biopolymer waste becomes less clear. Only when the system of green current certificates is dismissed, composting clearly is a much cheaper processing technique for disposing of biopolymer waste. Copyright © 2010 Elsevier Ltd. All rights reserved.
Pandya, K J; Morrow, G R; Roscoe, J A; Hickok, J T; Zhao, H; Pajon, E; Sweeney, T J; Banerjee, T K; Flynn, P J
2005-01-01
Summary Background Most women receiving systemic therapy for breast cancer experience hot flashes. We undertook a randomised, double-blind, placebo-controlled, multi-institutional trial to assess the efficacy of gabapentin in controlling hot flashes in women with breast cancer. Methods 420 women with breast cancer who were having two or more hot flashes per day were randomly assigned placebo, gabapentin 300 mg/day, or gabapentin 900 mg/day by mouth in three divided doses for 8 weeks. Each patient kept a 1-week, self-report diary on the frequency, severity, and duration of hot flashes before the start of the study and during weeks 4 and 8 of treatment. Analyses were by intention to treat. Findings Evaluable data were available on 371 participants at 4 weeks (119 placebo, 123 gabapentin 300 mg, and 129 gabapentin 900 mg) and 347 at 8 weeks (113 placebo, 114 gabapentin 300 mg, and 120 gabapentin 900 mg). The percentage decreases in hot-flash severity score between baseline and weeks 4 and 8, respectively were: 21% (95% CI 12 to 30) and 15% (1 to 29) in the placebo group; 33% (23 to 43) and 31% (16 to 46) in the group assigned gabapentin 300 mg; and 49% (42 to 56) and 46% (34 to 58) in the group assigned gabapentin 900 mg. The differences between the groups were significant (p=0.0001 at 4 weeks and p=0.007 at 8 weeks by ANCOVA for overall treatment effect, adjusted for baseline values); only the higher dose of gabapentin was associated with significant decreases in hot-flash frequency and severity. Interpretation Gabapentin is effective in the control of hot flashes at a dose of 900 mg/day, but not at a dose of 300 mg/day. This drug should be considered for treatment of hot flashes in women with breast cancer. PMID:16139656
Kolber, Zbigniew; Falkowski, Paul
1995-06-20
A fast repetition rate fluorometer device and method for measuring in vivo fluorescence of phytoplankton or higher plants chlorophyll and photosynthetic parameters of phytoplankton or higher plants by illuminating the phytoplankton or higher plants with a series of fast repetition rate excitation flashes effective to bring about and measure resultant changes in fluorescence yield of their Photosystem II. The series of fast repetition rate excitation flashes has a predetermined energy per flash and a rate greater than 10,000 Hz. Also, disclosed is a flasher circuit for producing the series of fast repetition rate flashes.
Measurement of O and Ti atom displacements in TiO 2 during flash sintering experiments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yoon, Bola; Yadav, Devinder; Raj, Rishi
In-situ flash experiments on rutile TiO 2 were performed at the synchrotron at the Brookhaven National Laboratory. Pair distribution function analysis of total X-ray scattering measurements yielded mean-square atomic displacements of oxygen and titanium atoms during the progression of the 3 stages of flash. The displacements are measured to be far greater for oxygen atoms than for titanium atoms. Thus, these large displacements may signal an “elastic softening” of the lattice, which, recently, has been predicted as a precursor to the onset of flash.
Freeware eLearning Flash-ECG for learning electrocardiography.
Romanov, Kalle; Kuusi, Timo
2009-06-01
Electrocardiographic (ECG) analysis can be taught in eLearning programmes with suitable software that permits the effective use of basic tools such as a ruler and a magnifier, required for measurements. The Flash-ECG (Research & Development Unit for Medical Education, University of Helsinki, Finland) was developed to enable teachers and students to use scanned and archived ECGs on computer screens and classroom projectors. The software requires only a standard web browser with a Flash plug-in and can be integrated with learning environments (Blackboard/WebCT, Moodle). The Flash-ECG is freeware and is available to medical teachers worldwide.
[Laser flash photolysis, EPR and Raman studies of liquids at elevated pressures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eyring, E.M.
1992-01-01
The proposed research will solve a number of analytical chemical problems in solutions with measurement techniques that benefit from the use of elevated hydrostatic pressures: stopped-flow spectrophotometry (Gd[sup 3+] + L(ligand), [RuL[sub 5]H[sub 2]O][sup 2+], laser flash photolysis of Mo(CO)[sub 6] + L, flash photolysis of binuclear metalloproteins), EPR spectroscopy (Gd[sup 3+] ion-exchanged into ETS-10 and ETAS-10 molecular sieves), laser flash photolysis kinetic studies of Mo(CO)[sub 6]-2,2'-bipyridine, and electrochemical studies of metalloporphyrins using resonance Raman spectroscopy.
[Laser flash photolysis, EPR and Raman studies of liquids at elevated pressures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eyring, E.M.
1992-10-01
The proposed research will solve a number of analytical chemical problems in solutions with measurement techniques that benefit from the use of elevated hydrostatic pressures: stopped-flow spectrophotometry (Gd{sup 3+} + L(ligand), [RuL{sub 5}H{sub 2}O]{sup 2+}, laser flash photolysis of Mo(CO){sub 6} + L, flash photolysis of binuclear metalloproteins), EPR spectroscopy (Gd{sup 3+} ion-exchanged into ETS-10 and ETAS-10 molecular sieves), laser flash photolysis kinetic studies of Mo(CO){sub 6}-2,2`-bipyridine, and electrochemical studies of metalloporphyrins using resonance Raman spectroscopy.
Negativly streched premixed flames
NASA Astrophysics Data System (ADS)
Krikunova, A. I.; Saveliev, A. S.; Son, E. E.
2018-01-01
An experimental study of gravity effect on the blow-off and flash-back borders of the conical methane-air flame (normal and ring-stabilized) was performed. The influence of the preferential diffusion on the flame behavior in vicinity of flash-back boundaries was observed. Under conditions at Lewis number Le > 1, the radius of curvature of the flame tip increased gradually approaching flash-back boundaries while for the lean methane-air flames (Le < 1) the radius decreased abruptly. It was shown that the burning velocity for lean flames is less than that for reach ones, so the flash-back occurs at higher strains.
Measurement of O and Ti atom displacements in TiO 2 during flash sintering experiments
Yoon, Bola; Yadav, Devinder; Raj, Rishi; ...
2017-12-29
In-situ flash experiments on rutile TiO 2 were performed at the synchrotron at the Brookhaven National Laboratory. Pair distribution function analysis of total X-ray scattering measurements yielded mean-square atomic displacements of oxygen and titanium atoms during the progression of the 3 stages of flash. The displacements are measured to be far greater for oxygen atoms than for titanium atoms. Thus, these large displacements may signal an “elastic softening” of the lattice, which, recently, has been predicted as a precursor to the onset of flash.
An upconverted photonic nonvolatile memory.
Zhou, Ye; Han, Su-Ting; Chen, Xian; Wang, Feng; Tang, Yong-Bing; Roy, V A L
2014-08-21
Conventional flash memory devices are voltage driven and found to be unsafe for confidential data storage. To ensure the security of the stored data, there is a strong demand for developing novel nonvolatile memory technology for data encryption. Here we show a photonic flash memory device, based on upconversion nanocrystals, which is light driven with a particular narrow width of wavelength in addition to voltage bias. With the help of near-infrared light, we successfully manipulate the multilevel data storage of the flash memory device. These upconverted photonic flash memory devices exhibit high ON/OFF ratio, long retention time and excellent rewritable characteristics.
Gamma ray flashes add to mystery of upper atmosphere
NASA Astrophysics Data System (ADS)
Atmospheric electricity research has come a long way since Benjamin Franklin's kite-flying days. But what researchers have been learning lately about above-thunderstorm electricity has wrought a whole new era of mysteries.For a start, last summer a Colorado meteorologist sparked interest in a terrestrial phenomenon that the community first observed more than 100 years ago: optical flashes that occur above thunderstorms—at least 30 km above Earth. Walter Lyons with the Ft. Collins-based Mission Research Corporation, demonstrated that such flashes are not anomalies, as conventional scientific wisdom had held. He filmed hundreds of flashes during a 2-week period.
Statistical Patterns in Natural Lightning
NASA Astrophysics Data System (ADS)
Zoghzoghy, F. G.; Cohen, M.; Said, R.; Inan, U. S.
2011-12-01
Every day millions of lightning flashes occur around the globe but the understanding of this natural phenomenon is still lacking. Fundamentally, lightning is nature's way of destroying charge separation in clouds and restoring electric neutrality. Thus, statistical patterns of lightning activity indicate the scope of these electric discharges and offer a surrogate measure of timescales for charge buildup in thunderclouds. We present a statistical method to investigate spatio-temporal correlations among lightning flashes using National Lightning Detection Network (NLDN) stroke data. By monitoring the distribution of lightning activity, we can observe the charging and discharging processes in a given thunderstorm. In particular, within a given storm, the flashes do not occur as a memoryless random process. We introduce the No Flash Zone (NFZ) which results from the suppressed probability of two consecutive neighboring flashes. This effect lasts for tens of seconds and can extend up to 15 km around the location of the initial flash, decaying with time. This suppression effect may be a function of variables such as storm location, storm phase, and stroke peak current. We develop a clustering algorithm, Storm-Locator, which groups strokes into flashes, storm cells, and thunderstorms, and enables us to study lightning and the NFZ in different geographical regions, and for different storms. The recursive algorithm also helps monitor the interaction among spatially displaced storm cells, and can provide more insight into the spatial and temporal impacts of lightning discharges.
Improving Flash Flood Prediction in Multiple Environments
NASA Astrophysics Data System (ADS)
Broxton, P. D.; Troch, P. A.; Schaffner, M.; Unkrich, C.; Goodrich, D.; Wagener, T.; Yatheendradas, S.
2009-12-01
Flash flooding is a major concern in many fast responding headwater catchments . There are many efforts to model and to predict these flood events, though it is not currently possible to adequately predict the nature of flash flood events with a single model, and furthermore, many of these efforts do not even consider snow, which can, by itself, or in combination with rainfall events, cause destructive floods. The current research is aimed at broadening the applicability of flash flood modeling. Specifically, we will take a state of the art flash flood model that is designed to work with warm season precipitation in arid environments, the KINematic runoff and EROSion model (KINEROS2), and combine it with a continuous subsurface flow model and an energy balance snow model. This should improve its predictive capacity in humid environments where lateral subsurface flow significantly contributes to streamflow, and it will make possible the prediction of flooding events that involve rain-on-snow or rapid snowmelt. By modeling changes in the hydrologic state of a catchment before a flood begins, we can also better understand the factors or combination of factors that are necessary to produce large floods. Broadening the applicability of an already state of the art flash flood model, such as KINEROS2, is logical because flash floods can occur in all types of environments, and it may lead to better predictions, which are necessary to preserve life and property.
FlaME: Flash Molecular Editor - a 2D structure input tool for the web.
Dallakian, Pavel; Haider, Norbert
2011-02-01
So far, there have been no Flash-based web tools available for chemical structure input. The authors herein present a feasibility study, aiming at the development of a compact and easy-to-use 2D structure editor, using Adobe's Flash technology and its programming language, ActionScript. As a reference model application from the Java world, we selected the Java Molecular Editor (JME). In this feasibility study, we made an attempt to realize a subset of JME's functionality in the Flash Molecular Editor (FlaME) utility. These basic capabilities are: structure input, editing and depiction of single molecules, data import and export in molfile format. The result of molecular diagram sketching in FlaME is accessible in V2000 molfile format. By integrating the molecular editor into a web page, its communication with the HTML elements on this page is established using the two JavaScript functions, getMol() and setMol(). In addition, structures can be copied to the system clipboard. A first attempt was made to create a compact single-file application for 2D molecular structure input/editing on the web, based on Flash technology. With the application examples presented in this article, it could be demonstrated that the Flash methods are principally well-suited to provide the requisite communication between the Flash object (application) and the HTML elements on a web page, using JavaScript functions.
Raji, A R; Sardari, K; Mohammadi, H R
2008-06-01
The purpose of this study was to define the structures of the digits and hoof in Holstein dairy cattle by using computed tomography scan (CT scan). Transverse, sagittal and dorsoplantar CT images of two isolated cattle cadaver digits were obtained using a Siemens ARTX2 Somatom. The CT images were compared to corresponding frozen cross-sections. Relevant anatomical structures were identified and labelled at each level. The CT images provided anatomical detail of the digits and hoof in Holstein dairy cattle. Transversal images provided excellent depiction of anatomical structures when compared to corresponding frozen cross-sections. The information presented in this paper would serve as an initial reference to the evaluation of CT images of the digits and hoof in Holstein dairy cattle.