Sample records for sonographically guided core

  1. Sonographically guided percutaneous muscle biopsy in diagnosis of neuromuscular disease: a useful alternative to open surgical biopsy.

    PubMed

    O'Sullivan, Paul J; Gorman, Grainne M; Hardiman, Orla M; Farrell, Michael J; Logan, P Mark

    2006-01-01

    The purpose of this study was to evaluate the feasibility of sonographically guided percutaneous muscle biopsy in the investigation of neuromuscular disorders. Sonographically guided percutaneous needle biopsy of skeletal muscle was performed with a 14-gauge core biopsy system in 40 patients over a 24-month period. Patients were referred from the Department of Neurology under investigation for neuromuscular disorders. Sonography was used to find suitable tissue and to avoid major vascular structures. A local anesthetic was applied below skin only. A 3- to 4-mm incision was made. Three 14-gauge samples were obtained from each patient. All samples were placed on saline-dampened gauze and sent for neuropathologic analysis. As a control, we retrospectively assessed results of the 40 most recent muscle samples acquired via open surgical biopsy. With the use of sonography, 32 (80%) of 40 patients had a histologic diagnosis made via percutaneous needle biopsy. This included 26 (93%) of 28 patients with acute muscular disease and 6 (50%) of 12 patients with chronic disease. In the surgical group (all acute disease), 38 (95%) of 40 patients had diagnostic tissue attained. Sonographically guided percutaneous 14-gauge core skeletal muscle biopsy is a useful procedure, facilitating diagnosis in acute muscular disease. It provides results comparable with those of open surgical biopsy in acute muscular disease. It may also be used in chronic muscular disease but repeated or open biopsy may be needed.

  2. Ultrasound-guided core needle biopsy of cervical lymph nodes in the diagnosis of toxoplasmosis.

    PubMed

    Cho, Woojin; Kim, Min Kyung; Sim, Jung Suk

    2017-05-01

    Our study investigates whether the histopathological features of toxoplasmic lymphadenitis (TL), specifically noncaseating microgranuloma and follicular hyperplasia, can be obtained by sonographic-guided core needle biopsy (CNB) of cervical lymph nodes. Thirty-two patients seen from June 2014 to March 2015 were positive for toxoplasma immunoglobulin M antibody. Among those patients, 21 underwent CNB of a cervical lymph node and were enrolled in this study. The pathologic findings were reviewed. Twenty-nine lymph nodes in 21 patients were sampled. Eighteen of the 21 (86%) patients had a microgranuloma without caseating necrosis or giant cells, and all 21 (100%) patients had follicular hyperplasia. The histologic findings of TL were detected by sonographic-guided CNB, which can be used as part of the first line of investigation in patients with unexplained cervical adenopathy. © 2016 Wiley Periodicals, Inc. J Clin Ultrasound 45:192-196, 2017. © 2016 Wiley Periodicals, Inc.

  3. Sonographically guided intrasheath percutaneous release of the first annular pulley for trigger digits, part 2: randomized comparative study of the economic impact of 3 surgical models.

    PubMed

    Rojo-Manaute, Jose Manuel; Capa-Grasa, Alberto; Del Cerro-Gutiérrez, Miguel; Martínez, Manuel Villanueva; Chana-Rodríguez, Francisco; Martín, Javier Vaquero

    2012-03-01

    Trigger digit surgery can be performed by an open approach using classic open surgery, by a wide-awake approach, or by sonographically guided first annular pulley release in day surgery and office-based ambulatory settings. Our goal was to perform a turnover and economic analysis of 3 surgical models. Two studies were conducted. The first was a turnover analysis of 57 patients allocated 4:4:1 into the surgical models: sonographically guided-office-based, classic open-day surgery, and wide-awake-office-based. Regression analysis for the turnover time was monitored for assessing stability (R(2) < .26). Second, on the basis of turnover times and hospital tariff revenues, we calculated the total costs, income to cost ratio, opportunity cost, true cost, true net income (primary variable), break-even points for sonographically guided fixed costs, and 1-way analysis for identifying thresholds among alternatives. Thirteen sonographically guided-office-based patients were withdrawn because of a learning curve influence. The wide-awake (n = 6) and classic (n = 26) models were compared to the last 25% of the sonographically guided group (n = 12), which showed significantly less mean turnover times, income to cost ratios 2.52 and 10.9 times larger, and true costs 75.48 and 20.92 times lower, respectively. A true net income break-even point happened after 19.78 sonographically guided-office-based procedures. Sensitivity analysis showed a threshold between wide-awake and last 25% sonographically guided true costs if the last 25% sonographically guided turnover times reached 65.23 and 27.81 minutes, respectively. However, this trial was underpowered. This trial comparing surgical models was underpowered and is inconclusive on turnover times; however, the sonographically guided-office-based approach showed shorter turnover times and better economic results with a quick recoup of the costs of sonographically assisted surgery.

  4. Minimal invasive complete excision of benign breast tumors using a three-dimensional ultrasound-guided mammotome vacuum device.

    PubMed

    Baez, E; Huber, A; Vetter, M; Hackelöer, B-J

    2003-03-01

    The aim of this study was to evaluate the use of three-dimensional (3D) ultrasonography in the complete excision of benign breast tumors using ultrasound-guided vacuum-assisted core-needle biopsy (Mammotome). A protocol for the management of benign breast tumors is proposed. Twenty consecutive patients with sonographically benign breast lesions underwent 3D ultrasound-guided mammotome biopsy under local anesthesia. The indication for surgical biopsy was a solid lesion with benign characteristics on both two-dimensional (2D) and 3D ultrasound imaging, increasing in size over time or causing pain or irritation. Preoperatively, the size of the lesion was assessed using 2D and 3D volumetry. During vacuum biopsy the needle was visualized sonographically in all three dimensions, including the coronal plane. Excisional biopsy was considered complete when no residual tumor tissue could be seen sonographically. Ultrasonographic follow-up examinations were performed on the following day and 3-6 months later to assess residual tissue and scarring. All lesions were histologically benign. Follow-up examinations revealed complete excision of all lesions of < 1.5 mL in volume as assessed by 3D volumetry. 3D ultrasonographic volume assessment was more accurate than 2D using the ellipsoid formula or assessment of the maximum diameter for the prediction of complete excision of the tumor. No bleeding or infections occurred postoperatively and no scarring was seen ultrasonographically on follow-up examinations. Ultrasound-guided vacuum-assisted biopsy allows complete excision of benign breast lesions that are

  5. Sonographically Guided Plantaris Tendon Release: A Cadaveric Validation Study.

    PubMed

    Smith, Jay; Alfredson, Håkan; Masci, Lorenzo; Sellon, Jacob L; Woods, Charonn D

    2018-06-13

    The plantaris tendon (PT) has been implicated in the pathogenesis of symptoms in a subset of patients with Achilles region pain syndromes and has been traditionally managed via open surgical resection. Although the PT can be visualized on ultrasound, a minimally invasive technique for sonographically guided PT release has not been formally described. To validate a technique to perform sonographically guided PT release in an unembalmed cadaveric model. Prospective, cadaveric laboratory investigation. Procedural skills laboratory in a tertiary medical center. Twenty unembalmed cadaveric knee-ankle-foot specimens (10 right, 10 left; 6 male, 10 female) from 16 donors ages 55-96 years (mean 82.6 years) with BMI's of 14.1 to 33.2 kg/m 2 (mean 23.3 kg/m 2 ). Following simulated local anesthesia and sonographically guided hydrodissection of the plantaris tendon-Achilles tendon interval, a single experienced operator performed sonographically guided PT release on each specimen using an in-plane, lateral to medial approach, a commercially available, disposable 3.0 mm hook knife, and either a 17-5 MHz or 15-7 MHz linear array transducer. Each specimen was subsequently dissected to assess for PT release and iatrogenic injury. Status of the PT, Achilles tendon, and regional neurovascular structures as determined by dissection. All 20 PT releases were completed in a single attempt through a 3-5 mm incision. Dissection confirmed complete PT release in all specimens without damage to the adjacent Achilles tendon or regional neurovascular structures. Sonographically guided PT release is technically feasible and can be performed while avoiding injury to the Achilles tendon and regional neurovascular structures. Additional research is warranted to further define the role of sonographically guided PT release in patients with suspected PT-mediated Achilles region pain syndromes. Copyright © 2018 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  6. Treatment of supraspinatus tendinopathy with ultrasound guided dry needling.

    PubMed

    Settergren, Roy

    2013-03-01

    The purpose of this case study is to describe the treatment of a patient with tendinopathy using sonographically guided dry needling. Tendinopathies are a highly prevalent problem in musculoskeletal medicine, and no one form of treatment has gained universal acceptance as being superior to another. A 30-year-old woman with a 4-month history of anterolateral right shoulder pain was diagnosed with supraspinatus tendinopathy upon physical examination, which was confirmed with diagnostic sonography. Sonography was used to guide an acupuncture needle into the pathologic tissue to induce a humoral healing response. Therapeutic exercise was also prescribed. At 10-day follow-up, increased echogenicity was found in the previously heterogenous hypoechoic areas. The patient also experienced a subjective resolution of her shoulder pain, which did not return with increased physical activity. Sonographically guided dry needling was shown to be beneficial for this patient as evident by sonographic changes pre- and postprocedure.

  7. Flat epithelial atypia of the breast: pathological-radiological correlation.

    PubMed

    Solorzano, Silma; Mesurolle, Benoît; Omeroglu, Attila; El Khoury, Mona; Kao, Ellen; Aldis, Ann; Meterissian, Sarkis

    2011-09-01

    This study was undertaken to determine the prevalence of flat epithelial atypia at ultrasound-guided and stereotactically guided needle biopsies, to describe the mammographic and sonographic features of flat epithelial atypia, and to determine the significance of lesions diagnosed as flat epithelial atypia at imaging-guided needle biopsies. Retrospective review of a database of 1369 consecutive sonographically and stereotactically guided needle biopsies performed during a 12-month period yielded 33 lesions with flat epithelial atypia as the most severe pathologic entity (32 patients). Two radiologists retrospectively reviewed the imaging presentation, by combined consensus, according to the BI-RADS lexicon. Twenty-two of 33 flat epithelial atypia diagnoses (67%) were obtained under stereotactic guidance, and 11 (33%) were obtained under sonographic guidance. Six patients had synchronous breast cancer. Flat epithelial atypia lesions presented mammographically most often as microcalcifications (20/33 [61%]) distributed in a cluster (14/20 [70%]) with amorphous morphology (13/20 [65%]). Sonographically, flat epithelial atypia lesions appeared most often as masses (9/11 [82%]), with an irregular shape (6/9 [67%]), microlobulated margins (5/9 [56%]), and hypoechoic or complex echotexture (7/9 [78%]). Twenty-eight of 33 lesions (85%) were surgically excised, confirming the flat epithelial atypia diagnosis in 11 of the 28 lesions (39%), yielding carcinoma in four (14%) and atypical ductal hyperplasia in six (21%). Columnar cell changes without atypia were diagnosed in four lesions (14%), and lobular carcinoma in situ was diagnosed in three lesions (11%). Mammographic and sonographic presentation of flat epithelial atypia is not specific (clustered amorphous microcalcifications and irregular, hypoechoic or complex masses). Given the underestimation rate of malignancy, surgical excision should be considered when imaging-guided biopsy yields flat epithelial atypia.

  8. Ultrasound-guided percutaneous bone drilling for the treatment of lateral epicondylitis.

    PubMed

    Yoo, Sang Ho; Cha, Jang Gyu; Lee, Bo Ra

    2018-01-01

    To determine the clinical efficacy of sonographically-guided percutaneous bone drilling of the lateral epicondyle (LE) for the treatment of patients with LE. We included 24 patients with LE who reported pain in this study. All patients underwent sonographically-guided percutaneous bone drilling of the lateral epicondyle. Follow-up sonography and physical examinations were performed 1, 3 and 6 months after the procedure. The outcome measures included sonographic findings, visual analogue scale (VAS) score, maximum voluntary grip strength (MVGS) and patient-related tennis elbow evaluation (PRTEE) score. None of the patients had immediate complications during the procedure. The area of the extensor carpi radialis brevis (ECRB) tears decreased significantly at 1 month and declined gradually over the remaining 5 months of the study (p < 0.001). The mean pain VAS score was significantly lower at 6 months than preoperatively (respectively; p < 0.001). The mean MVGS increased significantly between pretreatment and 6 months post-treatment (p < 0.001), whereas the PRTEE score decreased significantly during the same period (p < 0.001). Sonographically-guided percutaneous drilling is a quick and safe treatment option for LE that can be performed in an outpatient setting. • Percutaneous drilling of the lateral condyle is effective for the treatment of LE. • The area of ECRB tears can be measured by US-guided saline injection. • US-guided percutaneous drilling is a quick and safe treatment option for LE.

  9. Effect of abdominal liposuction on sonographically guided high-intensity focused ultrasound ablation.

    PubMed

    Zhao, Wen-Peng; Chen, Jin-Yun; Chen, Wen-Zhi

    2014-09-01

    The aim of this study was to evaluate the effect of abdominal liposuction on sonographically guided high-intensity focused ultrasound (HIFU) ablation. A total of 10 women with uterine fibroids or adenomyosis who had received abdominal liposuction were analyzed after sonographically guided HIFU ablation. Of the 10 women, 6 had a diagnosis of uterine fibroids, and 4 had a diagnosis of uterine adenomyosis. All of them had a history of a horizontal-margin split-cesarean delivery. In addition, 26 women with a history of a single horizontal-margin split-cesarean delivery who had a diagnosis of uterine fibroids or adenomyosis but had not received liposuction were analyzed together as a control group. Of the 10 women, 1 woman with uterine fibroids developed local skin erythema after treatment; 1 women with uterine adenomyosis developed a skin burn after treatment; and the remaining women had obvious skin-burning pain during treatment. All women who had not received liposuction finished the treatment with no serious adverse events during or after treatment. The pain scores and incidence of skin-burning pain were significantly higher in the liposuction group than the control group (P= .021 and .038, respectively). Abdominal liposuction may increase the risk of skin burns during sonographically guided HIFU ablation. © 2014 by the American Institute of Ultrasound in Medicine.

  10. Treatment of supraspinatus tendinopathy with ultrasound guided dry needling

    PubMed Central

    Settergren, Roy

    2013-01-01

    Objective The purpose of this case study is to describe the treatment of a patient with tendinopathy using sonographically guided dry needling. Tendinopathies are a highly prevalent problem in musculoskeletal medicine, and no one form of treatment has gained universal acceptance as being superior to another. Clinical Features A 30-year-old woman with a 4-month history of anterolateral right shoulder pain was diagnosed with supraspinatus tendinopathy upon physical examination, which was confirmed with diagnostic sonography. Intervention and Outcome Sonography was used to guide an acupuncture needle into the pathologic tissue to induce a humoral healing response. Therapeutic exercise was also prescribed. At 10-day follow-up, increased echogenicity was found in the previously heterogenous hypoechoic areas. The patient also experienced a subjective resolution of her shoulder pain, which did not return with increased physical activity. Conclusions Sonographically guided dry needling was shown to be beneficial for this patient as evident by sonographic changes pre- and postprocedure. PMID:23997721

  11. Sonographically guided percutaneous needle release of the carpal tunnel for treatment of carpal tunnel syndrome: preliminary report.

    PubMed

    McShane, John M; Slaff, Samantha; Gold, Judith E; Nazarian, Levon N

    2012-09-01

    The purpose of this study was to evaluate the effectiveness of a novel treatment procedure, sonographically guided percutaneous needle release of the carpal tunnel, for individuals with carpal tunnel syndrome. Seventeen patients (89% female; mean age, 62 years; SD, 13.6 years) with a clinical diagnosis of carpal tunnel syndrome who had undergone a sonographically guided percutaneous needle release of the carpal tunnel at least 6 months before follow-up evaluation were retrospectively reviewed. At the follow-up evaluation, to ascertain previous and current symptoms as well as functional impairment, the patients filled out a hand diagram and a questionnaire. In addition, medical records were reviewed, and patients were queried regarding complications such as infection or nerve damage. Median nerve sonographic measurements and a physical evaluation were performed on a subset of 13 patients who came to the office for evaluation. Postprocedure sonography showed that patients had a significantly smaller (P = .03) cross-sectional area of the median nerve compared to pretreatment values. In addition, patients had significantly fewer symptoms (P < .0001), less functional impairment (P = .0002), and an improved hand diagram score (P < .0001). Postprocedure patients had grip strength that was 12 lb below average (≈1 SD below) compared to grip strength norms. However, most patients (84.6%) had negative clinical diagnostic test results for carpal tunnel syndrome, and 86% said they were satisfied with the procedure. There were no procedure-related infections or nerve injuries. Of the patients with carpal tunnel syndrome who agreed to participate in this study, most had favorable symptomatic and functional outcomes. Sonographically guided percutaneous needle release of the carpal tunnel may be an alternative option to traditional surgical treatment of carpal tunnel syndrome.

  12. Sonographically guided percutaneous needle tenotomy for treatment of common extensor tendinosis in the elbow.

    PubMed

    McShane, John M; Nazarian, Levon N; Harwood, Marc I

    2006-10-01

    Chronic tendinosis of the common extensor tendon of the lateral elbow can be a difficult problem to treat. We report our experience with sonographically guided percutaneous needle tenotomy to relieve pain and improve function in patients with this condition. We performed sonographically guided percutaneous needle tenotomy on 58 consecutive patients who had persistent pain and disability resulting from common extensor tendinosis. Under a local anesthetic and sonographic guidance, a needle was advanced into the common extensor tendon, and the tip of the needle was used to repeatedly fenestrate the tendinotic tissue. Calcifications, if present, were mechanically fragmented, and the adjacent bony surface of the apex and face of the epicondyle were abraded. Finally, the fenestrated tendon was infiltrated with a solution containing corticosteroid mixed with bupivacaine. After the procedure, patients were instructed to perform passive stretches and to undergo physical therapy. During a subsequent telephone interview, patients answered questions about their experience, their functioning level, and their perceptions of procedure outcome. Fifty-five (95%) of 58 patients were contacted by telephone and agreed to participate in the study. Thirty-five (63.6%) of 55 respondents reported excellent outcomes, 16.4% good, 7.3% fair, and 12.7% poor. The average follow-up time from the date of the procedure to the date of the interview was 28 months (range, 17-44 months). No adverse events were reported; 85.5% stated that they would refer a friend or close relative for the procedure. Sonographically guided percutaneous needle tenotomy for lateral elbow tendinosis is a safe, effective, and viable alternative for patients in whom all other nonsurgical treatments failed.

  13. Sonographically guided percutaneous needle tenotomy for treatment of common extensor tendinosis in the elbow: is a corticosteroid necessary?

    PubMed

    McShane, John M; Shah, Vinil N; Nazarian, Levon N

    2008-08-01

    Chronic refractory common extensor tendinosis of the lateral elbow has been shown to respond to sonographically guided percutaneous needle tenotomy (PNT) followed by corticosteroid injection. In this analysis, we attempted to determine whether the corticosteroid is a necessary component of the procedure. We performed PNT on 57 consecutive patients (age range, 34-61 years) with persistent pain and disability resulting from common extensor tendinosis. Under a local anesthetic and sonographic guidance, a needle was advanced into the tendon, and the tip of the needle was used to fenestrate the tendinotic tissue, break up any calcifications, and abrade the adjacent bone. After the procedure, patients underwent a specified physical therapy protocol. During a subsequent telephone interview, patients answered questions about their symptoms, the level of functioning, and perceptions of the procedure outcome. Of the 52 patients who agreed to participate in the study, 30 (57.7%) reported excellent outcomes, 18 (34.6%) good, 1 (1.9%) fair, and 3 (5.8%) poor. The average follow-up time from the date of the procedure to the telephone interview was 22 months (range, 7-38 months). No adverse events were reported, and 90% stated that they would refer a friend or close relative for the procedure. Sonographically guided PNT for refractory lateral elbow tendinosis is an effective procedure, and subsequent corticosteroid injection is not necessary.

  14. Percutaneous aspiration of fluid for management of peritonitis in space

    NASA Technical Reports Server (NTRS)

    Kirkpatrick, A. W.; Nicolaou, S.; Campbell, M. R.; Sargsyan, A. E.; Dulchavsky, S. A.; Melton, S.; Beck, G.; Dawson, D. L.; Billica, R. D.; Johnston, S. L.; hide

    2002-01-01

    BACKGROUND: As a medical emergency that can affect even well-screened, healthy individuals, peritonitis developing during a long-duration space exploration mission may dictate deviation from traditional clinical practice due to the absence of otherwise indicated surgical capabilities. Medical management can treat many intra-abdominal processes, but treatment failures are inevitable. In these circumstances, percutaneous aspiration under sonographic guidance could provide a "rescue" strategy. Hypothesis: Sonographically guided percutaneous aspiration of intra-peritoneal fluid can be performed in microgravity. METHODS: Investigations were conducted in the microgravity environment of NASA's KC-135 research aircraft (0 G). The subjects were anesthetized female Yorkshire pigs weighing 50 kg. The procedures were rehearsed in a terrestrial animal lab (1 G). Colored saline (500 mL) was introduced through an intra-peritoneal catheter during flight. A high-definition ultrasound system (HDI-5000, ATL, Bothell, WA) was used to guide a 16-gauge needle into the peritoneal cavity to aspirate fluid. RESULTS: Intra-peritoneal fluid collections were easily identified, distinct from surrounding viscera, and on occasion became more obvious during weightless conditions. Subjectively, with adequate restraint of the subject and operators, the procedure was no more demanding than during the 1-G rehearsals. CONCLUSIONS: Sonographically guided percutaneous aspiration of intra-peritoneal fluid collections is feasible in weightlessness. Treatment of intra-abdominal inflammatory conditions in spaceflight might rely on pharmacological options, backed by sonographically guided percutaneous aspiration for the "rescue" of treatment failures. While this risk mitigation strategy cannot guarantee success, it may be the most practical option given severe resource limitations.

  15. Enthesopathy of the lateral cord of the plantar fascia.

    PubMed

    Hoffman, Douglas F; Nazarian, Levon N; Smith, Jay

    2014-09-01

    The objective of this study was to raise awareness of the diagnosis of enthesopathy of the lateral cord of the plantar fascia (LCPF) and describe its sonographic findings. We conducted a retrospective case series of 13 sonographic examinations with the diagnosis of LCPF enthesopathy. Two cadaver dissections of the plantar foot were performed for anatomic correlation. Sonographic findings of LCPF enthesopathy included generalized or focal hypoechoic thickening, loss of the normal fibrillar echo texture, cortical irregularity of the fifth metatarsal tuberosity, and vascularity on color Doppler imaging. Anatomic dissections of the plantar foot detailed the course of the LCPF and served as a guide for optimal sonographic imaging. Enthesopathy of the LCPF is an important etiology of nontraumatic pain at the base of the fifth metatarsal. Sonographic evaluation can readily show the characteristic findings of LCPF enthesopathy. © 2014 by the American Institute of Ultrasound in Medicine.

  16. Breast abscess after nipple piercing: sonographic findings with clinical correlation.

    PubMed

    Leibman, A Jill; Misra, Monika; Castaldi, Maria

    2011-09-01

    The purpose of this series was to review the spectrum of clinical and sonographic features associated with infection after nipple piercing. Between 2002 and 2010, 6 patients presented to our breast center with a breast abscess after nipple piercing. A retrospective analysis of the imaging findings was performed with clinical and pathologic correlation. Patients with breast infections after nipple piercing tend to be young, and the timing since piercing varies from 2 weeks to 17 months. Sonography showed a complex or hypoechoic mass in 5 of 6 patients. Treatment of breast abscesses included surgical incision and drainage, percutaneous drainage, and antibiotic therapy. Surgical evacuation is commonly performed; however, sonographically guided aspiration may be an appropriate management strategy.

  17. Sonographically guided deep plantar fascia injections: where does the injectate go?

    PubMed

    Maida, Eugene; Presley, James C; Murthy, Naveen; Pawlina, Wojciech; Smith, Jay

    2013-08-01

    To determine the distribution of sonographically guided deep plantar fascia injections in an unembalmed cadaveric model. A single experienced operator completed 10 sonographically guided deep plantar fascia injections in 10 unembalmed cadaveric specimens (5 right and 5 left) obtained from 6 donors (2 male and 4 female) aged 49 to 95 years (mean, 77.5 years) with a mean body mass index of 23.2 kg/m(2) (range, 18.4-26.3 kg/m(2)). A 12-3-MHz linear array transducer was used to direct a 22-gauge, 38-mm stainless steel needle deep to the plantar fascia at the anterior aspect of the calcaneus using an in-plane, medial-to-lateral approach. In each case, 1.5 mL of 50% diluted colored latex was injected deep to the plantar fascia. After a minimum of 72 hours, study coinvestigators dissected each specimen to assess injectate placement. All 10 injections accurately placed latex adjacent to the deep side of the plantar fascia at the anterior calcaneus. However, the flexor digitorum brevis (FDB) origin from the plantar fascia variably limited direct latex contact with the plantar fascia, and small amounts of latex interdigitated with the FDB origin in 90% (9 of 10). In all 10 specimens, latex also covered the traversing first branch of the lateral plantar nerve (FBLPN, ie, Baxter nerve) between the FDB and quadratus plantae muscles. No latex was found in the plantar fat pad or plantar fascia in any specimen. Sonographically guided deep plantar fascia injections reliably deliver latex deep to the plantar fascia while avoiding intrafascial injection. However, the extent of direct plantar fascia contact is variable due to the intervening FDB. On the contrary, the traversing FBLPN is reliably covered by the injection. Deep plantar fascia injections may have a role in the management of refractory plantar fasciitis, particularly following failed superficial perifascial or intrafascial injections, in cases of preferential deep plantar fascia involvement, or when entrapment/irritation of the distal FBLPN is suspected.

  18. Management of Intrauterine Arteriovenous Malformation (AVM) in 14 Patients by Sonographically Guided Tisseel Application.

    PubMed

    Bandura, Patrick; Rawnaq, Tamina; Holzknecht, Annette; Cetin, Emine; Reemts, Petra; Zoi, Panagiota; Schwärzler, Peter

    2018-02-01

     AVMs are rare tumorous vascular lesions derived from placental tissue that may present with massive post-partum hemorrhage (PPH) causing potentially life-threatening anemic shock. Current treatment options include the embolization of uterine arteries and emergency postpartum hysterectomy. We present a new form of minimally invasive, highly specific sonographically guided treatment in the form of the application of a human fibrin sealant leading to the instant cease of blood loss.  A management protocol was established and a case series of 14 patients is presented. Diagnosis by endovaginal color Doppler sonography is followed by the sonographically guided application of biological glue (TISSEEL ® ), thus allowing for super-selective occlusion of the feeding vessels.  The procedure was technically successful in all 14 patients, 3 of whom (21 %) had a repeated procedure after 4 - 7 days. The mean age (yrs.) of the patients was 31 (25 - 40), the gravity was median 2 (1 - 5) and the parity was median 1 (0 - 4), the lowest Hb value was on average 9.35 ± 2.25 (5.2 - 14.2) g/dl, the lowest Ht was on average 30.82 ± 6.02 (18 - 41 %). Spectral Doppler analysis revealed an average of 80.71 ± 11.2 (66 - 115) cm/sec for the maximal detectable PSV. In the period of 4 - 55 months after treatment, 7 patients (50 %) had 8 successful pregnancies and 2 miscarriages.  In PPH there is vital interest in timely diagnosis of the underlying cause, thus allowing fertility-sparing, minimally invasive and super-selective emergency treatment. In AVMs causing PPH, a positive impact on perinatal morbidity and mortality may be achieved by sonographically guided application of this biological glue. © Georg Thieme Verlag KG Stuttgart · New York.

  19. How to manage thyroid nodules with two consecutive non-diagnostic results on ultrasonography-guided fine-needle aspiration.

    PubMed

    Moon, Hee Jung; Kwak, Jin Young; Choi, Yoon Seong; Kim, Eun-Kyung

    2012-03-01

    The aim of this study was to investigate the factors for considering surgery on thyroid nodules that had non-diagnostic results on two consecutive cytology examinations. A total of 104 thyroid nodules with two consecutive non-diagnostic cytology examinations in 104 patients were investigated. Nodules with one or more suspicious ultrasonography (US) features of marked hypoechogenicity, a not well defined margin, microcalcifications, or a taller-than-wide shape were assessed as sonographically suspicious. Those without any suspicious features were assessed as sonographically benign. The clinicopathologic characteristics of patients and US features of the nodules were compared according to malignancy and benignity. The odds ratio for predicting malignancy was calculated. Altogether, 12 nodules were malignant, and 92 were benign. Age, sex, nodule size, and solidness were not associated with malignancy (P = 0.73, 0.92, 0.48, and 0.73, respectively). The malignancy rate of sonographically suspicious nodules was 25.7%, higher than the 4.3% of sonographically benign nodules (P = 0.002). The odds ratio of sonographically suspicious nodules for predicting malignancy was 16.01 (95% confidence interval 2.36-108.54, P = 0.005). Based on sonographic features, surgery can be performed selectively on nodules with two consecutive non-diagnostic cytology results.

  20. Diagnosis of peritoneal mesothelioma: computed tomography, sonography, and fine-needle aspiration biopsy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reuter, K.; Raptopoulos, V.; Reale, F.

    1983-06-01

    The diagnosis of peritoneal mesothelioma was made prospectively and noninvasively in four patients with the use of sonography, computed tomography, and sonographically guided fine-needle aspiration biopsy. The imaging methods revealed information similar to the operative findings, with clear superiority of computed tomography over sonography. These noninvasive methods may be used as screening tools, especially among groups or in regional areas with a high risk for asbestos exposure. The findings included soft-tissue masses with invariable involvement of the omentum; small intraperitoneal nodules; thickened peritoneum, mesentery, and bowel wall; pleural plaques; and usually minimal, if any, ascites. Since the differential diagnosis frommore » peritoneal carcinomatosis may be difficult, sonographically (or CT) guided aspiration biopsy is needed to produce diagnostic cytologic specimens. The use of this type of biopsy should obviate surgical exploration.« less

  1. The diagnostic and prognostic value of ultrasonography in soccer players with acute hamstring injuries.

    PubMed

    Petersen, Jesper; Thorborg, Kristian; Nielsen, Michael Bachmann; Skjødt, Thomas; Bolvig, Lars; Bang, Niels; Hölmich, Per

    2014-02-01

    An injury to the hamstring muscle complex is the most common injury in soccer. Ultrasound of acute hamstring injuries is often used as a clinical tool for diagnosing hamstring injuries and guiding players in when they can return to play. To (1) investigate the characteristic sonographic findings of acute hamstring injuries in soccer players, (2) compare the mean injury severity (time to return to play) in injured players with and without sonographically verified abnormalities, and (3) correlate the length of the injured area and absence from soccer play (time to return to play) to investigate if ultrasonography can be used as a prognostic indicator of time to return to play. Case series; Level of evidence, 4. Players from 50 teams participating in 1 of the top 5 Danish soccer divisions were followed in the period from January to December 2008. Of 67 players with acute hamstring injuries, 51 underwent ultrasonographic examination of the injured thigh and were included in this study. Ultrasonographic examinations were performed 1 to 10 days after injury (mean, 5.2 ± 3.0 days), and sonographic findings were present in 31 of 51 cases (61%). Two thirds of the injuries were to the biceps femoris muscle and one third to the semitendinosus muscle. No total ruptures were documented. The 51 acute hamstring injuries resulted in absence from soccer of a mean 25.4 ± 15.7 days per injury, with no significant difference between players with and without sonographically verified abnormalities (P = .41). No correlation existed between the length of the injured area and injury severity (r = 0.19, P = .29). The biceps femoris is the most commonly injured hamstring muscle detected by ultrasound, and more than half of the injuries are intramuscular. Because neither the presence of sonographic findings nor the size of the findings was correlated with time to return to play in injured soccer players, the prognosis of hamstring injuries should not be guided by these findings alone.

  2. Ultrasound-guided fine needle aspiration in the diagnosis of peripheral nerve sheath tumors in 4 dogs

    PubMed Central

    da Costa, Ronaldo C.; Parent, Joane M.; Dobson, Howard; Ruotsalo, Kristiina; Holmberg, David; Duque, M. Carolina; Poma, Roberto

    2008-01-01

    Ultrasound-guided fine needle aspiration was used in establishing the diagnosis in 4 cases of malignant peripheral nerve sheath tumor. Sonographic and cytologic characteristics are discussed. Because of its availability and ease of use, axillary ultrasonography with fine needle aspiration can be an initial diagnostic step for suspected brachial plexus tumors. PMID:18320983

  3. Ultrasound-guided steroid tendon sheath injections in juvenile idiopathic arthritis: a 10-year single-center retrospective study.

    PubMed

    Peters, Shannon E; Laxer, Ronald M; Connolly, Bairbre L; Parra, Dimitri A

    2017-04-11

    The aims of this study were to: (a) Identify tendon sheaths most commonly treated with steroid injections in a pediatric patient population with Juvenile Idiopathic Arthritis (JIA); (b) Describe technical aspects of the procedure; (c) Characterize sonographic appearance of tenosynovitis in JIA; (d) Assess agreement between clinical request and sites injected. This was a 10 year single-center retrospective study (May 2006-April 2016) of patients with JIA referred by Rheumatology for ultrasound-guided tendon sheath injections. Patient demographics, clinical referral information, sonographic appearance of the tendon sheaths and technical aspects of the procedure were analyzed. There were 308 procedures of 244 patients (75% female, mean age 9.6 years) who underwent a total of 926 tendon sheath injections. Ankle tendons were most commonly injected (84.9%), specifically the tendon sheaths of tibialis posterior (22.3%), peroneus longus (20%) and brevis (19.7%). The majority of treated sites (91.9%) showed peritendinous fluid and sheath thickening on ultrasound. There were 2 minor intra-procedure complications without sequelae. A good agreement between clinical request and sites injected was observed. Ultrasound-guided tendon sheath injections with steroids are used frequently to treat patients with JIA. It is a safe intervention with a high technical success rate. The ankle region, specifically the medial compartment, is the site most commonly injected in this group of patients. The most common sonographic finding is peritendinous fluid and sheath thickening. These findings might assist clinicians and radiologists to characterize and more effectively manage tenosynovitis in patients with JIA.

  4. Technical tips to perform safe and effective ultrasound guided steroid joint injections in children.

    PubMed

    Parra, Dimitri A

    2015-01-01

    The aim of this article is to describe the technique used to perform ultrasound guided steroid joint injections in children in a group of joints that can be injected using ultrasound as the only image guidance modality. The technique is described and didactic figures are provided to illustrate key technical concepts. It is very important to be familiar with the sonographic appearance of the pediatric joints and the developing bone when performing ultrasound-guided joint injections in children.

  5. The prepatellar bursa: cadaveric investigation of regional anatomy with MRI after sonographically guided bursography.

    PubMed

    Aguiar, Rodrigo O; Viegas, Flavio C; Fernandez, Rodrigo Y; Trudell, Debra; Haghighi, Parviz; Resnick, Donald

    2007-04-01

    The purpose of this study was to use MRI and anatomic correlation in cadavers to show the macroscopic anatomic configuration of the prepatellar bursa. MRI of the prepatellar bursa of nine cadaveric knees was performed after sonographically guided bursography. The images were compared with those seen on anatomic sectioning. Histologic analysis was obtained in two specimens. Mean dimensions of the prepatellar bursa in the craniocaudal, lateromedial, and anteroposterior planes were 39.7, 40.5, and 3.2 mm, respectively. A trilaminar aspect of the bursa was shown in seven of the nine knees (78%) and a bilaminar appearance in two of the nine knees (22%). Lateral extension of the bursa over the patella was observed in three knees (33%) and medial extension in one knee (11%). On histopathologic analysis, three potential bursal spaces were found. The prepatellar bursa is most commonly a trilaminar structure, and variation in its relation to the patella can occur.

  6. Sonographic findings predictive of central lymph node metastasis in patients with papillary thyroid carcinoma: influence of associated chronic lymphocytic thyroiditis on the diagnostic performance of sonography.

    PubMed

    Yoo, Yeon Hwa; Kim, Jeong-Ah; Son, Eun Ju; Youk, Ji Hyun; Kwak, Jin Young; Kim, Eun-Kyung; Park, Cheong Soo

    2013-12-01

    To analyze sonographic findings suggesting central lymph node metastasis of papillary thyroid carcinoma and to evaluate the influence of associated chronic lymphocytic thyroiditis on the diagnostic performance of sonography for predicting central lymph node metastasis. A total of 124 patients (101 female and 23 male; mean age, 47.5 years; range, 21-74 years) underwent sonographically guided fine-needle aspiration in central lymph nodes from January 2008 to July 2011. Sonographic features of size, shape, margin, thickening of the cortex, cortical echogenicity, presence of a hilum, cystic changes, calcification, and vascularity of enlarged lymph nodes were analyzed before fine-needle aspiration and classified into 2 categories (probably benign and suspicious). Sonographic findings were correlated with the pathologic diagnosis and associated chronic lymphocytic thyroiditis. Receiver operating characteristic curve analysis was performed to assess the diagnostic performance of sonography for predicting central lymph node metastasis according to the associated thyroiditis. Fifty-one lymph nodes (39.5%) were malignant, and 73 (60.5%) were benign. On univariate analysis, size, shape, margin, cortical thickening, cortical echogenicity, cystic changes, calcification, and vascularity were significantly different between the benign and metastatic nodes (P < .05). On multivariate analysis, eccentric cortical thickening (odds ratio, 26.59; 95% confidence interval [CI], 3.26-216.66) and hyper echogenicity of the cortex (odds ratio, 18.46; 95% CI, 2.44-139.64) were significantly associated with malignant nodes (P < .05). The area under the curve values for sonography for predicting metastasis were 0.756 (95% CI, 0.618-0.894) in chronic lymphocytic thyroiditis-positive patients and 0.971 (95% CI, 0.938-1.000) in negative patients. Eccentric cortical thickening and cortical hyperechogenicity were the sonographic findings predictive of central lymph node metastasis from papillary thyroid carcinoma. The diagnostic performance of sonography for predicting metastasis was superior in chronic lymphocytic thyroiditis-negative patients than in positive patients.

  7. Validation of American Thyroid Association Ultrasound Risk Assessment of Thyroid Nodules Selected for Ultrasound Fine-Needle Aspiration.

    PubMed

    Tang, Alice L; Falciglia, Mercedes; Yang, Huaitao; Mark, Jonathan R; Steward, David L

    2017-08-01

    The aim of this study was to validate the American Thyroid Association (ATA) sonographic risk assessment of thyroid nodules. The ATA sonographic risk assessment was prospectively applied to 206 thyroid nodules selected for ultrasound-guided fine-needle aspiration (US-FNA), and analyzed with The Bethesda System for Reporting Thyroid Cytopathology (TBSRTC), as well as surgical pathology for the subset undergoing surgical excision. The analysis included 206 thyroid nodules averaging 2.4 cm (range 1-7 cm; standard error of the mean 0.07). Using the ATA US pattern risk assessment, nodules were classified as high (4%), intermediate (31%), low (38%), and very low (26%) risk of malignancy. Nodule size was inversely correlated with sonographic risk assessment, as lower risk nodules were larger on average (p < 0.0001). Malignancy rates determined by cytology/surgical pathology were high 100%, intermediate 11%, low 8%, and very low 2%, which were closely aligned with ATA malignancy risk estimates (high 70-90%, intermediate 10-20%, low 5-10%, and very low 3%). ATA US pattern risk assessment also appropriately predicted the proportion of nodules classified as malignant or suspicious for malignancy through TBSRTC classification-high (77%), intermediate (6%), low (1%), and very low 0%-as well as benign TBSRTC classification-high (0%), intermediate (47%), low (61%), and very low (70%) (p < 0.0001). Malignancy rates of surgically excised, cytologically indeterminate nodules followed ATA sonographic risk stratification (high 100%, intermediate 21%, low 17%, and very low 12%; p = 0.003). This prospective study supports the new ATA sonographic pattern risk assessment for selection of thyroid nodules for US-FNA based upon TBSRTC and surgical pathology results. In the setting of indeterminate cytopathology, nodules categorized as atypia of undetermined significance/follicular lesion of undetermined significance with ATA high-risk sonographic patterns have a high likelihood of being malignant.

  8. Solo Sonographically Guided PCNL under Spinal Anesthesia: Defining Predictors of Success.

    PubMed

    Nouralizadeh, Akbar; Pakmanesh, Hamid; Basiri, Abbas; Aayanifard, Mohammad; Soltani, Mohammad Hossein; Tabibi, Ali; Sharifiaghdas, Farzaneh; Ziaee, Seyed Amir Mohsen; Shakhssalim, Naser; Valipour, Reza; Narouie, Behzad; Radfar, Mohammad Hadi

    2016-01-01

    Aim. Sonography has been brought in percutaneous nephrolithotripsy (PCNL) as an adjunct to or substitute for X-ray to restrict radiation exposure. This study was designed to investigate the possible predictors for the success of the solo sonographically guided PCNL. Methods. 148 consecutive cases were prospectively enrolled. All steps of PCNL were performed solely with sonography guidance under spinal anesthesia. Residual stones were evaluated the day after surgery using sonography and plain radiography. Results. The mean age was 46 ± 15 years; 40% of kidneys had hydronephrosis. The mean stone burden was 504 ± 350 mm(2). The mean duration of surgery was 43 ± 21 minutes. The early stone-free rate was 92% in inferior or middle calyceal stones, 89.5% in single pelvic stones, 81.5% in partial staghorn stones, and 61.9% in staghorn stones. The mean residual stone size was 13 ± 8 mm. Logistic regression showed that a lower age and a larger stone burden significantly predicted positive residual stones. Fifteen percent of patients presented with grade I or II and six percent showed grade III complication based on Clavien classification. There was no cases of organ injury or death. Conclusion. Solo ultrasonographically guided PCNL under spinal anesthesia is feasible with an acceptable stone-free rate and complication rate.

  9. Sonographically guided posteromedial approach for intra-articular knee injections: a safe, accurate, and efficient method.

    PubMed

    Tresley, Jonathan; Jose, Jean

    2015-04-01

    Osteoarthritis of the knee can be a debilitating and extremely painful condition. In patients who desire to postpone knee arthroplasty or in those who are not surgical candidates, percutaneous knee injection therapies have the potential to reduce pain and swelling, maintain joint mobility, and minimize disability. Published studies cite poor accuracy of intra-articular knee joint injections without imaging guidance. We present a sonographically guided posteromedial approach to intra-articular knee joint injections with 100% accuracy and no complications in a consecutive series of 67 patients undergoing subsequent computed tomographic or magnetic resonance arthrography. Although many other standard approaches are available, a posteromedial intra-articular technique is particularly useful in patients with a large body habitus and theoretically allows for simultaneous aspiration of Baker cysts with a single sterile preparation and without changing the patient's position. The posteromedial technique described in this paper is not compared or deemed superior to other standard approaches but, rather, is presented as a potentially safe and efficient alternative. © 2015 by the American Institute of Ultrasound in Medicine.

  10. Lung flooding enables efficient lung sonography and tumour imaging in human ex vivo and porcine in vivo lung cancer model

    PubMed Central

    2013-01-01

    Background Sonography has become the imaging technique of choice for guiding intraoperative interventions in abdominal surgery. Due to artefacts from residual air content, however, videothoracoscopic and open intraoperative ultrasound-guided thermoablation of lung malignancies are impossible. Lung flooding is a new method that allows complete ultrasound imaging of lungs and their tumours. Methods Fourteen resected tumourous human lung lobes were examined transpleurally with B-mode ultrasound before (in atelectasis) and after lung flooding with isotonic saline solution. In two swine, the left lung was filled with 15 ml/kg isotonic saline solution through the left side of a double-lumen tube. Lung tumours were simulated by transthoracic ultrasound-guided injection of 5 ml of purified bovine serum albumin in glutaraldehyde, centrally into the left lower lung lobe. The rate of tumour detection, the severity of disability caused by residual gas, and sonomorphology of the lungs and tumours were assessed. Results The ex vivo tumour detection rate was 100% in flooded human lung lobes and 43% (6/14) in atelectatic lungs. In all cases of atelectasis, sonographic tumour imaging was impaired by residual gas. Tumours and atelectatic tissue were isoechoic. In 28% of flooded lungs, a little residual gas was observed that did not impair sonographic tumour imaging. In contrast to tumours, flooded lung tissue was hyperechoic, homogeneous, and of fine-grained structure. Because of the bronchial wall three-laminar structure, sonographic differentiation of vessels and bronchi was possible. In all cases, malignant tumours in the flooded lung appeared well-demarcated from the lung parenchyma. Adenocarcinoma, squamous, and large cell carcinomas were hypoechoic. Bronchioloalveolar cell carcinoma was slightly hyperechoic. Transpleural sonography identifies endobronchial tumour growth and bronchial wall destruction. With transthoracic sonography, the flooded animal lung can be completely examined in vivo. There is no residual gas, which interferes with ultrasound. Pulmonary vessels and bronchi are clearly differentiated. Simulated lung lesions can easily be detected inside the lung lobe. Conclusions Lung flooding enables complete lung sonography and tumour detection. We have developed a novel method that efficiently uses ultrasound for guiding intraoperative interventions in open and endoscopic lung surgery. PMID:23841910

  11. Sonographically-guided vacuum-assisted biopsy with digital mammography-guided skin marking of suspicious breast microcalcifications: comparison of outcomes with stereotactic biopsy in Asian women.

    PubMed

    Hahn, Soo Yeon; Shin, Jung Hee; Han, Boo-Kyung; Ko, Eun Young

    2011-02-01

    Management of suspicious microcalcifications in very thin breasts is problematic. To evaluate whether sonographically-guided vacuum-assisted biopsy (USVAB) with digital mammography-guided skin marking (DM) for the diagnosis of breast microcalcifications is comparable to stereotactic-guided vacuum-assisted biopsy (SVAB) in Asian women with thin breasts. Retrospective review was performed for 263 consecutive suspicious microcalcification lesions in 261 women who underwent USVAB with DM or SVAB using a prone table between January 2004 and December 2007. SVAB was performed for 190 lesions and USVAB for 73 lesions. Biopsy results were correlated with surgical pathology or followed up for at least 12 months. The diagnostic outcomes of SVAB and USVAB to diagnose microcalcifications were compared. Of 263 lesions, 104 (40%) underwent surgery and 159 (60%) were followed up. SVAB and USVAB groups showed similar final categories or the extent of microcalcifications. US visible lesions were 57 (78%) of 73 at USVAB and 14 (10%) of 140 at SVAB. Of 57 US visible lesions at USVAB, 29 (51%) were not found in initial US but were detectable with the help of DM. Specimen radiographs were negative in 2.1% of lesions at SVAB and in 4.1% at USVAB (p=0.4008). The under-estimation rate and false-negative rate were similar in SVAB and USVAB. US with DM facilitates US visibility of microcalcifications. USVAB with DM can produce acceptable biopsy results, as can SVAB, to diagnose breast microcalcifications in patients with thin breasts.

  12. Ultrasonography of thyroid nodules: a pictorial review.

    PubMed

    Xie, Cheng; Cox, Peter; Taylor, Nia; LaPorte, Sarah

    2016-02-01

    Thyroid nodules are a common occurrence in the general population, and these incidental thyroid nodules are often referred for ultrasound (US) evaluation. US provides a safe and fast method of examination. It is sensitive for the detection of thyroid nodules, and suspicious features can be used to guide further investigation/management decisions. However, given the financial burden on the health service and unnecessary anxiety for patients, it is unrealistic to biopsy every thyroid nodule to confirm diagnosis. The British Thyroid Association (BTA) has recently produced a US classification (U1-U5) of thyroid nodules to facilitate the decision-making process regarding the need to perform fine-needle aspiration cytology (FNAC) for suspicious cases. In this pictorial review, we provide a complete series of sonographic images to illustrate benign and malignant features of thyroid nodules according to the U1-5 classification. Specifically, we highlight morphologic characteristic of the nodule, including its echo signal in relation to its consistency, nodular size, number and contour. Additional diagnostic features such as halo, colloid, calcification and vascular patterns are also discussed in detail. The aim is to assist radiologists and clinicians in recognising sonographic patterns of benign, suspicious and malignant nodules based on U1-5 criteria, and in planning for further investigations. • Ultrasound is sensitive in identifying suspicious features, which require aspiration. • Whether nodules require aspiration should be based on sonographic features and clinical findings. • U1-5 classification of sonographic findings can help determine whether aspiration is necessary.

  13. The Role of Conventional Ultrasound in the Assessment of Thyroid Nodule in Erbil City

    ERIC Educational Resources Information Center

    Musa, Sarbast Ismail; Hanary, Salah Mohammad

    2016-01-01

    Background: Nodular thyroid disease is relatively common although thyroid cancer is rare. The aim of this study is to evaluate the advantage and reliability of conventional ultrasound in correlating sonographic characteristics of thyroid nodule with US-FNAC guided result as a diagnostic aid in thyroid nodule. Method: 111 patients were examined by…

  14. Sonographic features of neonatal mastitis and breast abscess.

    PubMed

    Borders, Heather; Mychaliska, George; Gebarski, K Stiennon

    2009-09-01

    Neonatal mastitis and neonatal breast abscess are uncommon. Although well described in the pediatric and surgical literature, there is a paucity of reports describing their sonographic features. To describe and illustrate the sonographic features of neonatal mastitis and neonatal breast abscess. We reviewed the medical database of a large children's health-care center from 2000 through 2008 for patients presenting in the first 8 weeks of life with mastitis. The findings were correlated with clinical presentation and course, laboratory findings and clinical outcome. Four neonates (three girls and one boy) presented with mastitis. They all had prominent breast buds on the affected side with poorly defined margins, slightly more echogenic focally or diffusely compared to normal with hyperemia on color flow Doppler US. The surrounding subcutaneous tissue was thick and echogenic. Two abscesses presented as avascular areas without color flow on Doppler US, subtly increased through-transmission and surrounding hyperemia. One abscess was of increased echogenicity while the other was anechoic. Neonatal mastitis and breast abscess are unusual diseases that should be appropriately treated with antibiotics and drainage to avoid generalized sepsis, breast hypoplasia, and scarring. US is useful in distinguishing mastitis from breast abscess and guiding treatment options.

  15. Cytological Results of Ultrasound-Guided Fine-Needle Aspiration Cytology for Thyroid Nodules: Emphasis on Correlation with Sonographic Findings

    PubMed Central

    Lee, Mi-Jung; Hong, Soon Won; Chung, Woung Youn; Kwak, Jin Young; Kim, Min Jung

    2011-01-01

    Purpose To compare the cytological results of ultrasound-guided fine-needle aspiration (US-FNA) cytology of thyroid nodules to sonographic findings and determine whether US findings are helpful in the interpretation of cytological results. Materials and Methods Among the thyroid nodules that underwent US-FNA cytology, we included the 819 nodules which had a conclusive diagnosis. Final diagnosis was based on pathology from surgery, repeated FNA cytology or follow-up of more than one year. Cytological results were divided into five groups: benign, indeterminate (follicular or Hurthle cell neoplasm), suspicious for malignancy, malignant, and inadequate. US findings were categorized as benign or suspicious. Cytological results and US categories were analyzed. Results Final diagnosis was concluded upon in 819 nodules based on pathology (n=311), repeated FNA cytology (n=204) and follow-up (n=304), of which 634 were benign and 185 were malignant. There were 560 benign nodules, 141 malignant nodules, 49 nodules with inadequate results, 21 with indeterminate results, and 48 that were suspicious for malignancy. The positive and negative predictive values of the US categories were 59.1% and 97.0%, and those of the cytological results were 93.7% and 98.9%. The US categories were significantly correlated with final diagnosis in the benign (p=0.014) and suspicious for malignancy (p<0.001) cytological result groups, but not in the inadequate and indeterminate cytological results groups. The false positive and negative rates of cytological results were 1.9% and 3.2%. Conclusion Sonographic findings can be useful when used alongside cytological results, especially in nodules with cytological results that are benign or suspicious for malignancy. PMID:21786450

  16. Rapid diagnosis of liver cancer by ultrasound-guided fine-needle aspiration biopsy.

    PubMed

    Huber, K; Heuhold, N

    1987-01-01

    Because of the relatively favorable prognosis to the patient with early detected hepatocarcinoma followed by surgical treatment if resection is possible, it is important to differentiate quickly between primary and secondary liver cancer. Ultrasound-guided percutaneous fine needle aspiration biopsy (US-FNAB) was used as a first diagnostic measure in patients with sonographic evidence of liver tumors. Biopsies were done under sonographic control and antiseptic conditions from the center and the border zone of solid tumors of the liver, and the aspirated cell material was air dried on glass slides and Giemsa stained. The cytologic diagnosis was proved by clinical course and in most cases by surgical or autoptic histology. Cytologic evaluation lead in 15 cases to the diagnosis of definitive or suspicious malignant liver disease; the sensitivity was 93% and the specificity was 87%. One case classified as suspicious for malignancy by cytologic examination could be identified as cirrhotic nodule by further investigations. In none of the patients did we find complications from the biopsy procedure. From these data it is concluded that US-FNAB can serve as a rapid, inexpensive, safe, and highly accurate first diagnostic step in patients with solid lesions of the liver.

  17. B-Mode ultrasound pose recovery via surgical fiducial segmentation and tracking

    NASA Astrophysics Data System (ADS)

    Asoni, Alessandro; Ketcha, Michael; Kuo, Nathanael; Chen, Lei; Boctor, Emad; Coon, Devin; Prince, Jerry L.

    2015-03-01

    Ultrasound Doppler imaging may be used to detect blood clots after surgery, a common problem. However, this requires consistent probe positioning over multiple time instances and therefore significant sonographic expertise. Analysis of ultrasound B-mode images of a fiducial implanted at the surgical site offers a landmark to guide a user to the same location repeatedly. We demonstrate that such an implanted fiducial may be successfully detected and tracked to calculate pose and guide a clinician consistently to the site of surgery, potentially reducing the ultrasound experience required for point of care monitoring.

  18. MRI follow-up after concordant, histologically benign diagnosis of breast lesions sampled by MRI-guided biopsy.

    PubMed

    Li, Jie; Dershaw, D David; Lee, Carol H; Kaplan, Jennifer; Morris, Elizabeth A

    2009-09-01

    Follow-up MRI can be useful to confirm a benign diagnosis after MRI-guided breast biopsy. This retrospective study was undertaken to evaluate appropriate timing and imaging interpretation for the initial follow-up MRI when a benign, concordant histology is obtained using MRI-guided breast biopsy. Retrospective review was performed of 177 lesions visualized only by MRI in 172 women who underwent 9-gauge, vacuum-assisted core biopsy and marker placement with imaging-concordant benign histology. All underwent follow-up MRI within 12 months. Timing of the follow-up study, change in size, results of second biopsy if performed, and distance of localizing marker to the lesion on the follow-up study were recorded. At initial follow-up, 155 lesions were decreased or gone, 14 lesions were stable, and eight were enlarged. Seventeen (9.6%, 17/177) lesions underwent a second biopsy, including six enlarging, 10 stable, and one decreasing. Of these, four were malignant. Enlargement was seen in two carcinomas at 6 and 12 months. Two carcinomas, one stable at 2 months and another stable at 3 and 11 months, were rebiopsied because of suspicion of a missed lesion in the former and worrisome mammographic and sonographic changes in the latter. The distance of the marker from the lesion on follow-up did not correlate with biopsy accuracy. Follow-up MRI did not detect missed cancers because of lesion enlargement before 6 months after biopsy; two of four missed cancers were stable. The localizing marker can deploy away from the target despite successful sampling.

  19. Ultrasound-guided, minimally invasive, percutaneous needle puncture treatment for tennis elbow.

    PubMed

    Zhu, Jiaan; Hu, Bing; Xing, Chunyan; Li, Jia

    2008-10-01

    This report evaluates the efficacy of percutaneous needle puncture under sonographic guidance in treating lateral epicondylitis (tennis-elbow). Ultrasound-guided percutaneous needle puncture was performed on 76 patients who presented with persistent elbow pain. Under a local anesthetic and sonographic guidance, a needle was advanced into the calcification foci and the calcifications were mechanically fragmented. This was followed by a local injection of 25 mg prednisone acetate and 1% lidocaine. If no calcification was found then multiple punctures were performed followed by local injection of 25 mg prednisone acetate and 1% lidocaine. A visual analog scale (VAS) was used to evaluate the degree of pain pre-and posttreatment at 1 week to 24 weeks. Elbow function improvement and degree of self-satisfaction were also evaluated. Of the 76 patients, 55% were rated with excellent treatment outcome, 32% good, 11% average, and 3% poor. From 3 weeks posttreatment, VAS scores were significantly reduced compared with the pretreatment score (P<0.05) and continued to gradually decline up to 24 weeks posttreatment. Sonography demonstrated that the calcified lesions disappeared completely in 13% of the patients, were reduced in 61% of the patients, and did not change in 26% of the patients. Color Doppler flow signal used to assess hemodynamic changes showed a significant improvement after treatment in most patients. Ultrasound-guided percutaneous needle puncture is an effective and minimally invasive treatment for tennis elbow. Sonography can be used to accurately identify the puncture location and monitor changes.

  20. A prospective study of three diagnostic sonographic methods in differentiation between benign and malignant salivary gland tumours

    PubMed Central

    El-Khateeb, SM; Abou-Khalaf, AE; Farid, MM; Nassef, MA

    2011-01-01

    Objective The aim of this study was to evaluate the role of three diagnostic sonographic methods, greyscale sonography (GSS), colour Doppler sonography (CDS) and spectral Doppler (SPD), in differentiating between benign and malignant salivary gland (SG) tumours. Methods 44 patients with SG masses were examined using GSS, CDS and SPD. The morphological features of each tumour were evaluated using GSS, the distribution and number of detected blood vessels were assessed using CDS, and peak systolic velocity (PSV), resistive index (RI) and pulsatility index (PI) were measured on SPD. All cases underwent excisional biopsy and a definite tissue diagnosis was obtained. Results Histopathological examination revealed that 28 of the 44 tumours were benign and 16 were malignant. GSS showed that malignant SG tumours had a significantly higher incidence of ill-defined borders and lymph node involvement than benign tumours, but there was no significant difference between benign and malignant SG tumours regarding echogenicity, homogeneity or sonographic shape. CDS demonstrated malignant tumours with significantly higher vascularity and a scattered distribution. Using SPD, malignant tumours had significantly higher PSV, RI and PI compared with benign tumours. Conclusion RI values above 0.7, PI values above 1.2, PSV values above 44.3 cm s–1, ill-defined borders, lymph node involvement, Grade 2 or 3 vascularity and hilar distribution of blood vessels should alert the clinician to suspect a malignant SG tumour. After consensus on the threshold values of PSV, RI and PI in differentiating benign from malignant SG tumours, these numbers should be incorporated into the software of ultrasound machines to guide the sonographer in his or her analysis. PMID:22065796

  1. Collaborating with cardiac sonographers to develop work-related musculoskeletal disorder interventions.

    PubMed

    Sommerich, Carolyn M; Lavender, Steven A; Evans, Kevin; Sanders, Elizabeth; Joines, Sharon; Lamar, Sabrina; Radin Umar, Radin Zaid; Yen, Wei-Ting; Li, Jing; Nagavarapu, Shasank; Dickerson, Jennifer A

    2016-09-01

    For more than two decades, surveys of imaging technologists, including cardiac sonographers, diagnostic medical sonographers and vascular technologists, have consistently reported high prevalence of work-related musculoskeletal discomfort (WRMSD). Yet, intervention research involving sonographers is limited. In this study, we used a participatory approach to identifying needs and opportunities for developing interventions to reduce sonographers' exposures to WRMSD risk factors. In this paper, we present some of those needs. We include descriptions of two interventions, targeted for cardiac sonographers, that were developed, through an iterative process, into functional prototypes that were evaluated in pilot tests by practicing sonographers. One of these interventions is now in daily use. We would like other engineers and ergonomists to recognise this area of opportunity to apply their knowledge of biomechanics and design in order to begin to address the high prevalence of WRMSDs in sonographers, by working with sonographers to develop useful and usable interventions. Practitioner Summary: This paper discusses needs, opportunities and methods for working with sonographers in order to develop interventions to reduce their exposure to risk factors for work-related musculoskeletal discomfort. Results from field tests of two novel interventions targeting cardiac sonographers are also presented.

  2. Comparing Physical Examination With Sonographic Versions of the Same Examination Techniques for Splenomegaly.

    PubMed

    Cessford, Tara; Meneilly, Graydon S; Arishenkoff, Shane; Eddy, Christopher; Chen, Luke Y C; Kim, Daniel J; Ma, Irene W Y

    2017-12-08

    To determine whether sonographic versions of physical examination techniques can accurately identify splenomegaly, Castell's method (Ann Intern Med 1967; 67:1265-1267), the sonographic Castell's method, spleen tip palpation, and the sonographic spleen tip technique were compared with reference measurements. Two clinicians trained in bedside sonography patients recruited from an urban hematology clinic. Each patient was examined for splenomegaly using conventional percussion and palpation techniques (Castell's method and spleen tip palpation, respectively), as well as the sonographic versions of these maneuvers (sonographic Castell's method and sonographic spleen tip technique). Results were compared with a reference standard based on professional sonographer measurements. The sonographic Castell's method had greater sensitivity (91.7% [95% confidence interval, 61.5% to 99.8%]) than the traditional Castell's method (83.3% [95% confidence interval, 51.6% to 97.9%]) but took longer to perform [mean ± SD, 28.8 ± 18.6 versus 18.8 ± 8.1 seconds; P = .01). Palpable and positive sonographic spleen tip results were both 100% specific, but the sonographic spleen tip method was more sensitive (58.3% [95% confidence interval, 27.7% to 84.8%] versus 33.3% [95% confidence interval, 9.9% to 65.1%]). Sonographic versions of traditional physical examination maneuvers have greater diagnostic accuracy than the physical examination maneuvers from which they are derived but may take longer to perform. We recommend a combination of traditional physical examination and sonographic techniques when evaluating for splenomegaly at the bedside. © 2017 by the American Institute of Ultrasound in Medicine.

  3. Collaborating with cardiac sonographers to develop work-related musculoskeletal disorder interventions

    PubMed Central

    Sommerich, Carolyn M.; Lavender, Steven A.; Evans, Kevin; Sanders, Elizabeth; Joines, Sharon; Lamar, Sabrina; Umar, Radin Zaid Radin; Yen, Wei-Ting; Li, Jing; Nagavarapu, Shasank; Dickerson, Jennifer A.

    2016-01-01

    For more than two decades, surveys of imaging technologists, including cardiac sonographers, diagnostic medical sonographers, and vascular technologists, have consistently reported high prevalence of work-related musculoskeletal discomfort (WRMSD). Yet, intervention research involving sonographers is limited. In this study, we used a participatory approach to identifying needs and opportunities for developing interventions to reduce sonographers’ exposures to WMSD risk factors. In this paper, we present some of those needs. We include descriptions of two interventions, targeted for cardiac sonographers, that were developed, through an iterative process, into functional prototypes that were evaluated in pilot tests by practicing sonographers. One of these interventions is now in daily use. We would like other engineers and ergonomists to recognize this area of opportunity to apply their knowledge of biomechanics and design in order to begin to address the high prevalence of WRMSDs in sonographers, by working with sonographers to develop useful and usable interventions. PMID:26642863

  4. EUS Needle Identification Comparison and Evaluation study (with videos).

    PubMed

    Tang, Shou-Jiang; Vilmann, Andreas S; Saftoiu, Adrian; Wang, Wanmei; Streba, Costin Teodor; Fink, Peter P; Griswold, Michael; Wu, Ruonan; Dietrich, Christoph F; Jenssen, Christian; Hocke, Michael; Kantowski, Marcus; Pohl, Jürgen; Fockens, Paul; Annema, Jouke T; van der Heijden, Erik H F M; Havre, Roald Flesland; Pham, Khanh Do-Cong; Kunda, Rastislav; Deprez, Pierre H; Mariana, Jinga; Vazquez-Sequeiros, Enrique; Larghi, Alberto; Buscarini, Elisabetta; Fusaroli, Pietro; Lahav, Maor; Puri, Rajesh; Garg, Pramod Kumar; Sharma, Malay; Maluf-Filho, Fauze; Sahai, Anand; Brugge, William R; Lee, Linda S; Aslanian, Harry R; Wang, Andrew Y; Shami, Vanessa M; Markowitz, Arnold; Siddiqui, Ali A; Mishra, Girish; Scheiman, James M; Isenberg, Gerard; Siddiqui, Uzma D; Shah, Raj J; Buxbaum, James; Watson, Rabindra R; Willingham, Field F; Bhutani, Manoop S; Levy, Michael J; Harris, Cynthia; Wallace, Michael B; Nolsøe, Christian Pállson; Lorentzen, Torben; Bang, Niels; Sørensen, Sten Mellerup; Gilja, Odd Helge; D'Onofrio, Mirko; Piscaglia, Fabio; Gritzmann, Norbert; Radzina, Maija; Sparchez, Zeno Adrian; Sidhu, Paul S; Freeman, Simon; McCowan, Timothy C; de Araujo, Cyrillo Rodrigues; Patel, Akash; Ali, Mohammad Adel; Campbell, Garth; Chen, Edward; Vilmann, Peter

    2016-09-01

    EUS-guided FNA or biopsy sampling is widely practiced. Optimal sonographic visualization of the needle is critical for image-guided interventions. Of the several commercially available needles, bench-top testing and direct comparison of these needles have not been done to reveal their inherent echogenicity. The aims are to provide bench-top data that can be used to guide clinical applications and to promote future device research and development. Descriptive bench-top testing and comparison of 8 commonly used EUS-FNA needles (all size 22 gauge): SonoTip Pro Control (Medi-Globe); Expect Slimline (Boston Scientific); EchoTip, EchoTip Ultra, EchoTip ProCore High Definition (Cook Medical); ClearView (Conmed); EZ Shot 2 (Olympus); and BNX (Beacon Endoscopic), and 2 new prototype needles, SonoCoat (Medi-Globe), coated by echogenic polymers made by Encapson. Blinded evaluation of standardized and unedited videos by 43 EUS endoscopists and 17 radiologists specialized in GI US examination who were unfamiliar with EUS needle devices. There was no significant difference in the ratings and rankings of these needles between endosonographers and radiologists. Overall, 1 prototype needle was rated as the best, ranking 10% to 40% higher than all other needles (P < .01). Among the commercially available needles, the EchoTip Ultra needle and the ClearView needle were top choices. The EZ Shot 2 needle was ranked statistically lower than other needles (30%-75% worse, P < .001). All FNA needles have their inherent and different echogenicities, and these differences are similarly recognized by EUS endoscopists and radiologists. Needles with polymeric coating from the entire shaft to the needle tip may offer better echogenicity. Copyright © 2016 American Society for Gastrointestinal Endoscopy. All rights reserved.

  5. Fluoroscopy and Sonographic Guided Injection of Obliquus Capitis Inferior Muscle in an Intractable Occipital Neuralgia

    PubMed Central

    Kim, Ok Sun; Jeong, Seung Min; Ro, Ji Young; Kim, Duck Kyoung; Koh, Young Cho; Ko, Young Sin; Lim, So Dug; Kim, Hae Kyoung

    2010-01-01

    Occipital neuralgia is a form of headache that involves the posterior occiput in the greater or lesser occipital nerve distribution. Pain can be severe and persistent with conservative treatment. We present a case of intractable occipital neuralgia that conventional therapeutic modalities failed to ameliorate. We speculate that, in this case, the cause of headache could be the greater occipital nerve entrapment by the obliquus capitis inferior muscle. After steroid and local anesthetic injection into obliquus capitis inferior muscles under fluoroscopic and sonographic guidance, the visual analogue scale was decreased from 9-10/10 to 1-2/10 for 2-3 weeks. The patient eventually got both greater occipital neurectomy and partial resection of obliquus capitis inferior muscles due to the short term effect of the injection. The successful steroid and local anesthetic injection for this occipital neuralgia shows that the refractory headache was caused by entrapment of greater occipital nerves by obliquus capitis inferior muscles. PMID:20552081

  6. Locoregional spread of cutaneous melanoma: sonography findings.

    PubMed

    Catalano, Orlando; Caracò, Corrado; Mozzillo, Nicola; Siani, Alfredo

    2010-03-01

    This article reviews various aspects of locoregional spread of malignant cutaneous melanoma, as imaged with gray-scale sonography and Doppler techniques. The scenarios illustrated include disease staging (primary melanoma, satellite metastasis, in-transit metastasis, and lymphadenopathies), sentinel lymph node biopsy procedure, patient follow-up, recurrence detection, cutaneous metastasis, and sonographically guided intervention. High-resolution sonography allows recognition of small, clinically-occult melanomatous foci. It plays a major role in locoregional staging and follow-up of patients with cutaneous melanoma.

  7. Ultrasound Imaging and Guided Injection for the Lateral and Posterior Hip.

    PubMed

    Chang, Ke-Vin; Wu, Wei-Ting; Lew, Henry L; Özçakar, Levent

    2018-04-01

    Ultrasound has emerged as one of the most utilized tools to diagnose musculoskeletal disorders and to assist in interventions. Traditionally, sonographic examination of the hip joint has been challenging because most of the major structures are deeply situated, thus requiring the use of curvilinear transducer for better penetrance. The posterior lateral hip is a frequent area for musculoskeletal pain and nerve entrapments. Common disorders include greater trochanteric pain syndrome, gluteus medius tendinopathy, piriformis syndrome, pudendal neuralgia, and proximal hamstring tendinopathy. The present review article aims to delineate sonoanatomy of the posterior lateral hip and to exemplify several common ultrasound guided procedures at the greater trochanteric, gluteal, and ischial tuberosity regions.

  8. Sonographic Assessment of the Normal Dimensions of Liver, Spleen, and Kidney in Healthy Children at Tertiary Care Hospital.

    PubMed

    Thapa, N B; Shah, S; Pradhan, A; Rijal, K; Pradhan, A; Basnet, S

    2015-01-01

    Background Ultrasonography is one of the most common imaging modality to measure dimensions of visceral organs in children. However, the normal limit of size of visceral organs according to age and body habitus has not been specified in the standard textbooks. This might result in under detection of organomegaly in pediatrics population. Objective The objective of this study was to determine the normal range of dimensions for the liver, spleen, and kidney in healthy children. Method This is prospective cross-sectional, hospital-based study done at Tertiary-care teaching hospital. Participants included 272 pediatric subjects (152 male and 120 female) with normal physical or sonographic findings who were examined because of problems unrelated to the measured organs. The subjects were one month to 15 year (180 months) old. All measured organs were sonographically normal. Relationships of the dimensions of these organs with sex, age, body weight and height were investigated. Limits of normal dimensions of these organs were defined. Result Normal length of liver, kidneys and spleen were obtained sonographically for 272 children (152 male [55.9%] and 120 female [44.1%]) in the age group from 1 months to 15 (180 months) years. The mean age was 45.78 months (SD, 44.73). The measured dimensions of all these organs showed highest correlation with height and age so the descriptive analysis of the organ dimensions (mean, minimum, and maximum values, SD and 5th and 95th percentiles) were expressed in 10 age groups along with height range of the included children. The mean length of right kidney was shorter than the left kidney length, and the difference was statistically significant (p = 0.001). Conclusion This study provides practical and comprehensive guide to the normal visceral organ dimension in pediatric population. The normal range limit of the liver, spleen, and kidney determined in this study could be used as a reference in daily practice in local radiology clinics.

  9. Correlation between transvaginal ultrasound measured endometrial thickness and histopathological findings in Turkish women with abnormal uterine bleeding.

    PubMed

    Ozer, Alev; Ozer, Serdar; Kanat-Pektas, Mine

    2016-05-01

    The present study aims to determine how transvaginal ultrasonography and histopathological examination findings are correlated in a cohort of premenopausal and postmenopausal Turkish women with abnormal uterine bleeding. This is a retrospective review of 350 Turkish women who underwent transvaginal ultrasonography and suction curettage as a result of abnormal uterine bleeding. Sonographic appearance of the endometrium was normal in 244 patients (69.7%), while homogeneous thickening was detected in 47 patients (13.4%) and cystic thickening in 21 patients (6.0%). A sonographic diagnosis of endometrial polyp was made in 38 patients (10.9%). Histopathological analysis of endometrial samplings revealed proliferative endometrium (36%), secretory endometrium (24.6%), decidualization (10.9%), endometrial polyp (8.3%), endometritis (6.8%), endometrial hyperplasia (4.6%), irregular shedding (3.7%), atrophic endometrium (3.1%), endometrial cancer (1.1%) and placental retention (0.9%). The sonographic and histopathological findings correlated significantly (χ(2) = 122 768, P = 0.001; r = 0.215, P = 0.001). Approximately 51% of the women with homogeneous endometrial thickening had proliferative endometrium. Only 44.7% of the women with ultrasonographically visualized endometrial polyps had histopathologically diagnosed endometrial polyps. Nearly 57% of the women with cystic endometrial thickening had proliferative endometrium. If there is no facility for hysteroscopy or hysteroscopy-guided endometrial biopsy for women with abnormal uterine bleeding, transvaginal ultrasonography findings can be efficiently used to make a preliminary diagnosis and, thus, notify the pathologists. © 2016 Japan Society of Obstetrics and Gynecology.

  10. Ultrasound-guided block of sciatic and femoral nerves: an anatomical study.

    PubMed

    Waag, Sonja; Stoffel, Michael H; Spadavecchia, Claudia; Eichenberger, Urs; Rohrbach, Helene

    2014-04-01

    The sheep is a popular animal model for human biomechanical research involving invasive surgery on the hind limb. These painful procedures can only be ethically justified with the application of adequate analgesia protocols. Regional anaesthesia as an adjunct to general anaesthesia may markedly improve well-being of these experimental animals during the postoperative period due to a higher analgesic efficacy when compared with systemic drugs, and may therefore reduce stress and consequently the severity of such studies. As a first step 14 sheep cadavers were used to establish a new technique for the peripheral blockade of the sciatic and the femoral nerves under sonographic guidance and to evaluate the success rate by determination of the colorization of both nerves after an injection of 0.5 mL of a 0.1% methylene blue solution. First, both nerves were visualized sonographically. Then, methylene blue solution was injected and subsequently the length of colorization was measured by gross anatomical dissection of the target nerves. Twenty-four sciatic nerves were identified sonographically in 12 out of 13 cadavers. In one animal, the nerve could not be ascertained unequivocally and, consequently, nerve colorization failed. Twenty femoral nerves were located by ultrasound in 10 out of 13 cadavers. In three cadavers, signs of autolysis impeded the scan. This study provides a detailed anatomical description of the localization of the sciatic and the femoral nerves and presents an effective and safe yet simple and rapid technique for performing peripheral nerve blocks with a high success rate.

  11. Characterization of the major histopathological components of thyroid nodules using sonographic textural features for clinical diagnosis and management.

    PubMed

    Chen, Shao-Jer; Yu, Sung-Nien; Tzeng, Jeh-En; Chen, Yen-Ting; Chang, Ku-Yaw; Cheng, Kuo-Sheng; Hsiao, Fu-Tsung; Wei, Chang-Kuo

    2009-02-01

    In this study, the characteristic sonographic textural feature that represents the major histopathologic components of the thyroid nodules was objectively quantified to facilitate clinical diagnosis and management. A total of 157 regions-of-interest thyroid ultrasound image was recruited in the study. The sonographic system used was the GE LOGIQ 700), (General Electric Healthcare, Chalfant St. Giles, UK). The parameters affecting image acquisition were kept in the same condition for all lesions. Commonly used texture analysis methods were applied to characterize thyroid ultrasound images. Image features were classified according to the corresponding pathologic findings. To estimate their relevance and performance to classification, ReliefF was used as a feature selector. Among the various textural features, the sum average value derived from co-occurrence matrix can well reflect echogenicity and can effectively differentiate between follicles and fibrosis base thyroid nodules. Fibrosis shows lowest echogenicity and lowest difference sum average value. Enlarged follicles show highest echogenicity and difference sum average values. Papillary cancer or follicular tumors show the difference sum average values and echogenicity between. The rule of thumb for the echogenicity is that the more follicles are mixed in, the higher the echo of the follicular tumor and papillary cancer will be and vice versa for fibrosis mixed. Areas with intermediate and lower echo should address the possibility of follicular or papillary neoplasm mixed with either follicles or fibrosis. These areas provide more cellular information for ultrasound guided aspiration

  12. MRI of Adnexal Masses in Pregnancy

    PubMed Central

    Telischak, Nicholas A.; Yeh, Benjamin M.; Joe, Bonnie N.; Westphalen, Antonio C.; Poder, Liina; Coakley, Fergus V.

    2009-01-01

    OBJECTIVE The objective of this article is to provide a practical review of the incremental benefit of MRI in the assessment of adnexal masses in pregnancy. CONCLUSION MRI can assist sonographic assessment of adnexal masses in pregnancy by depicting the characteristic findings of exophytic leiomyoma, red degeneration of leiomyoma, endometrioma, decidualized endometrioma, and massive ovarian edema. Accordingly, MRI should be considered as a useful adjunct when sonography is inconclusive or insufficient to guide management of adnexal masses discovered in pregnancy. PMID:18647903

  13. The cardiac sonography workforce in New Zealand.

    PubMed

    Buckley, Belinda; White, Steve; Poppe, Katrina; Whalley, Gillian

    2013-05-01

    Introduction : The aim of this paper is to investigate the cardiac sonography workforce characteristics and registration requirements in New Zealand (NZ), with a comparison to similar workforces internationally. Methods : The Survey of Clinical Echocardiography in New Zealand 2 (SCANZ2) audit was performed in December 2010. All of NZ's public-funded District Health Board (DHB) centers providing echocardiography services responded to questions relating to staff, equipment, procedure types and patient statistics. The Medical Radiation Technologists Board (MRTB), Clinical Physiologists Registration Board (CPRB) and Australian Sonographers Association Registry (ASAR) websites were reviewed in March 2012 for registered sonographers with a cardiac scope of practice. The cardiac sonography workforces in Australia, the UK, the USA and Canada were investigated for comparison. Results : There are 84 cardiac sonographers (60.3 full-time equivalent) working in DHBs: 71% from a cardiac technical background; 40% have post-graduate qualifications; a further 17% are undertaking post-graduate qualifications; and 59 cardiac sonographers have registration with professional bodies in NZ and/or Australia. Cardiac sonographers in NZ do not undergo compulsory registration, but other sonographers in NZ have compulsory registration with the MRTB. Sonographers are predominantly not licensed internationally. Discussion : Disparity exists between registration of cardiac and non-cardiac sonographers in NZ. Many cardiac sonographers have voluntary registration but few are registered with the MRTB. Reasons for this include professional alignment, educational qualifications and representation. International trends show increased pressure from governments and professional bodies to regulate sonographers. Conclusion : This study provides a snapshot of the cardiac sonography workforce in NZ for the first time.

  14. The cardiac sonography workforce in New Zealand

    PubMed Central

    White, Steve; Poppe, Katrina; Whalley, Gillian

    2015-01-01

    Abstract Introduction: The aim of this paper is to investigate the cardiac sonography workforce characteristics and registration requirements in New Zealand (NZ), with a comparison to similar workforces internationally. Methods: The Survey of Clinical Echocardiography in New Zealand 2 (SCANZ2) audit was performed in December 2010. All of NZ's public‐funded District Health Board (DHB) centers providing echocardiography services responded to questions relating to staff, equipment, procedure types and patient statistics. The Medical Radiation Technologists Board (MRTB), Clinical Physiologists Registration Board (CPRB) and Australian Sonographers Association Registry (ASAR) websites were reviewed in March 2012 for registered sonographers with a cardiac scope of practice. The cardiac sonography workforces in Australia, the UK, the USA and Canada were investigated for comparison. Results: There are 84 cardiac sonographers (60.3 full‐time equivalent) working in DHBs: 71% from a cardiac technical background; 40% have post‐graduate qualifications; a further 17% are undertaking post‐graduate qualifications; and 59 cardiac sonographers have registration with professional bodies in NZ and/or Australia. Cardiac sonographers in NZ do not undergo compulsory registration, but other sonographers in NZ have compulsory registration with the MRTB. Sonographers are predominantly not licensed internationally. Discussion: Disparity exists between registration of cardiac and non‐cardiac sonographers in NZ. Many cardiac sonographers have voluntary registration but few are registered with the MRTB. Reasons for this include professional alignment, educational qualifications and representation. International trends show increased pressure from governments and professional bodies to regulate sonographers. Conclusion: This study provides a snapshot of the cardiac sonography workforce in NZ for the first time. PMID:28191178

  15. Use of quantitative analysis of sonographic brightness for detection of early healing of tendon injury in horses.

    PubMed

    Micklethwaite, L; Wood, A K; Sehgal, C M; Polansky, M; Dowling, B A; Dart, A J; Rose, R J; Hodgson, D R

    2001-08-01

    To determine whether quantitative analysis of sonographic brightness could be used to detect healing of an induced injury of the superficial digital flexor tendon in horses and whether rate of healing was influenced by equine recombinant growth hormone. 8 clinically normal Standardbreds. A localized injury was created in the left and right superficial digital flexor tendons of each horse by injection of 2,000 units of collagenase. After injury, 4 horses received equine recombinant growth hormone, a possible promoter of tendon healing. Sonographic images (7.5 MHz) of the flexor tendons and ligaments of the metacarpal region were recorded on videotape prior to injury and weekly for 7 weeks after injury. Images were digitized, and sonographic brightness of tendons and ligaments was calculated. Collagenase-induced injury was sonographically similar to naturally occurring injury. After injury, sonographic brightness of the tendon decreased; after 3 weeks, brightness progressively increased, although by 7 weeks brightness had not returned to preinjury value. Equine recombinant growth hormone had no significant effect on the rate of tendon healing, as evaluated sonographically or at necropsy. As healing developed, alterations in sonographic brightness of injured tendons coincided with real changes in tendon structure. Quantitative sonographic brightness could be used to accurately monitor healing of equine tendon and ligament injuries and investigate the efficacy of various treatment regimens.

  16. Sonographic evaluation of induced abortion--experience in Nigeria.

    PubMed

    Adetiloye, V A; Dare, F O

    1998-01-01

    A sonographic evaluation of forty-six patients with suspected complications of unsafe induced abortion was performed prospectively. The sonographic features were correlated with surgical findings. Based on the sonographic findings, the patients were categorised into three groups. There was no clear association between the severity of sonographic or pathological findings and the time of presentation for ultrasound after the termination of pregnancy, but most of the patients presenting after 5 days belonged to groups II and III, i.e. had uterine complications with or without abdomino-pelvic complications. The commonest complication, sepsis, is variably expressed sonographically in all groups. Although, the sonographic appearances of sepsis are similar to those seen in pelvic inflammatory disease (PID), some features seen with post-abortal sepsis are peculiar. Apart from sepsis, other complications of abortion presented non-specific sonographic features. "Pseudouterus" appearance was demonstrated in one patient after hysterectomy. The likelihood of pre-operative diagnosis of uterine perforation is high when the presentation is early before the formation of complex echopatterns of sepsis or in the absence of free intraperitoneal gas from bowel perforation or gas-forming organism. Routing manual vacuum aspiration or therapeutic endometrial curettage is unnecessary where sonography shows no evidence of retained products post abortion.

  17. Radiation exposure to sonographers from nuclear medicine patients: A review.

    PubMed

    Earl, Victoria Jean; Badawy, Mohamed Khaldoun

    2018-06-01

    Following nuclear medicine scans a patient can be a source of radiation exposure to the hospital staff, including sonographers. Sonographers are not routinely monitored for occupational radiation exposure as they do not commonly interact with radioactive patients or other sources of ionizing radiation. This review aims to find evidence relating to the risk and amount of radiation the sonographer is exposed to from nuclear medicine patients. It is established in the literature that the radiation exposure to the sonographer following diagnostic nuclear medicine studies is low and consequently the risk is not significant. Nevertheless, it is paramount that basic radiation safety principles are followed to ensure any exposure to ionizing radiation is kept as low as reasonably achievable. Practical recommendations are given to assist the sonographer in radiation protection. Nuclear medicine therapy procedures may place the sonographer at higher risk and as such consultation with a Radiation Safety Officer or Medical Physicist as to the extent of exposure is recommended. © 2018 The Royal Australian and New Zealand College of Radiologists.

  18. Ultrasonographic Changes at 12 Weeks of Anti-TNF Drugs Predict 1-year Sonographic Response and Clinical Outcome in Crohn's Disease: A Multicenter Study.

    PubMed

    Ripollés, Tomás; Paredes, José M; Martínez-Pérez, María J; Rimola, Jordi; Jauregui-Amezaga, Arantza; Bouzas, Rosa; Martin, Gregorio; Moreno-Osset, Eduardo

    2016-10-01

    The objective was to assess the long-term effect of biological treatment on transmural lesions of Crohn's disease evaluated with ultrasound, including contrast-enhanced ultrasound. Fifty-one patients with active Crohn's disease were included in a prospective multicenter longitudinal study. All patients underwent a clinical assessment and sonographic examination at baseline, 12 weeks after treatment initiation, and after 1-year of treatment. Patients were clinically followed at least 2 years from inclusion until the end of the study. Ultrasonographic evaluation included bowel wall thickness, color Doppler grade, parietal enhancement, and presence of transmural complications or stenosis. Sonographic changes after treatment were classified as normalization, improvement, or lack of response. Improvement at 52 weeks was more frequent in patients with improvement at final of induction (12 weeks) compared with patients who did not improve (85% versus 28%; P < 0.0001). One-year sonographic evolution correlated with clinical response; 28 of the 29 (96.5%) patients with sonographic improvement at 52 weeks showed clinical remission or response. Patients without sonographic improvement at 52 weeks of treatment were more likely to have a change or intensification in medication or surgery (13/20, 65%) during the next year of follow-up than patients with improvement on the sonography (3/28, 11%). Stricturing behavior was the only sonographic feature associated to a negative predictive value of response (P = 0.0001). Sonographic response after 12 weeks of therapy is more pronounced and predicts 1-year sonographic response. Sonographic response at 1-year examination correlates with 1-year clinical response and is a predictor of further treatment's efficacy, 1-year or longer period of follow-up.

  19. The student's dilemma, liver edition: incorporating the sonographer's language into clinical anatomy education.

    PubMed

    Hall, M Kennedy; Mirjalili, S Ali; Moore, Christopher L; Rizzolo, Lawrence J

    2015-01-01

    Anatomy students are often confused by multiple names ascribed to the same structure by different clinical disciplines. Increasingly, sonography is being incorporated into clinical anatomical education, but ultrasound textbooks often use names unfamiliar to the anatomist. Confusion is worsened when ultrasound names ascribed to the same structure actually refer to different structures. Consider the sonographic main lobar fissure (MLF). The sonographic MLF is a hyper-echoic landmark used by sonographers of the right upper quadrant. Found in approximately 70% of people, there is little consensus on what the sonographic MLF is anatomically. This structure appears to be related to the main portal fissure (aka principal plane of the liver or principal hepatic fissure), initially described by anatomists and surgeons as in intrahepatic division along the middle hepatic vein which in essence divides the territories of the left and right hepatic arteries and biliary systems. By exploring the relationship between the main portal fissure and the sonographic MLF in cadaveric livers ex vivo, the data suggest the sonographic MLF is actually an extrahepatic structure that parallels the rim of the main portal fissure. The authors recommend that this structure be renamed the "sonographic cystic pedicle," which includes the cystic duct and ensheathing fat and blood vessels. In the context of the redefined underlying anatomy, the absence of the sonographic cystic pedicle due to anatomic variation may serve an important clinical role in predicting complications from difficult laparoscopic cholecystectomies and is deserving of future study. © 2015 American Association of Anatomists.

  20. Ultrasound physics and instrumentation for pathologists.

    PubMed

    Lieu, David

    2010-10-01

    Interest in pathologist-performed ultrasound-guided fine-needle aspiration is increasing. Educational courses discuss clinical ultrasound and biopsy techniques but not ultrasound physics and instrumentation. To review modern ultrasound physics and instrumentation to help pathologists understand the basis of modern ultrasound. A review of recent literature and textbooks was performed. Ultrasound physics and instrumentation are the foundations of clinical ultrasound. The key physical principle is the piezoelectric effect. When stimulated by an electric current, certain crystals vibrate and produce ultrasound. A hand-held transducer converts electricity into ultrasound, transmits it into tissue, and listens for reflected ultrasound to return. The returning echoes are converted into electrical signals and used to create a 2-dimensional gray-scale image. Scanning at a high frequency improves axial resolution but has low tissue penetration. Electronic focusing moves the long-axis focus to depth of the object of interest and improves lateral resolution. The short-axis focus in 1-dimensional transducers is fixed, which results in poor elevational resolution away from the focal zone. Using multiple foci improves lateral resolution but degrades temporal resolution. The sonographer can adjust the dynamic range to change contrast and bring out subtle masses. Contrast resolution is limited by processing speed, monitor resolution, and gray-scale perception of the human eye. Ultrasound is an evolving field. New technologies include miniaturization, spatial compound imaging, tissue harmonics, and multidimensional transducers. Clinical cytopathologists who understand ultrasound physics, instrumentation, and clinical ultrasound are ready for the challenges of cytopathologist-performed ultrasound-guided fine-needle aspiration and core-needle biopsy in the 21st century.

  1. Views of physicians in training on the ethical and legal issues in preliminary reporting of echocardiographic data.

    PubMed

    McDonald, R W; Rice, M J; Marcella, C P; Reller, M D; Imus, R L

    1991-01-01

    Cardiac sonographers may be pressured by physicians into giving diagnostic interpretations of echocardiographic data. This study investigated the issue of preliminary reporting of echocardiographic data. A questionnaire was sent to 292 physicians; 85 physicians (29%) responded. Seventy-two physicians (87%) thought they had more than a minimal knowledge of echocardiography, 94% wanted a written or verbal preliminary report, and 84% thought that giving a preliminary report should be part of the cardiac sonographer's job. If abnormalities were found, 80% wanted the results before a cardiologist reviewed the study, and 56% would want a diagnostic rather than a descriptive report. Fifty-four physicians (64%) would pressure the cardiac sonographer into giving a preliminary echocardiographic report and would use this information to manage the patient. The majority of the physicians thought that it is legal for the cardiac sonographer to give a preliminary echocardiogram report. Eighty percent said that the cardiac sonographer would not be "practicing medicine without a license," and 82% that the sonographer would not be "aiding and abetting the unauthorized practice of medicine." This data would indicate that physicians at Oregon Health Sciences University want the cardiac sonographer to give preliminary echocardiographic results, even though the sonographer may be breaking state statutes.

  2. Comparison of fine-needle aspiration and core needle biopsy under ultrasonographic guidance for detecting malignancy and for the tissue-specific diagnosis of salivary gland tumors.

    PubMed

    Eom, H-J; Lee, J H; Ko, M-S; Choi, Y J; Yoon, R G; Cho, K J; Nam, S Y; Baek, J H

    2015-06-01

    Diagnostic test accuracy studies for ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy have shown inconclusive results due to their heterogenous study designs. Our aim was to compare the diagnostic accuracy of ultrasonography-guided fine-needle aspiration versus ultrasonography-guided core needle biopsy for detecting malignant tumors of the salivary gland and for the tissue-specific diagnosis of salivary gland tumors in a single tertiary hospital. This retrospective study was approved by our institutional review board and informed consent was waived. Four hundred twelve patients who underwent ultrasonography-guided fine-needle aspiration (n = 155) or ultrasonography-guided core needle biopsy (n = 257) with subsequent surgical confirmation or clinical follow-up were enrolled. We compared the diagnostic accuracy of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy regarding malignant salivary gland tumors and the correct tissue-specific diagnosis of benign and malignant tumors. We also tested the difference between these procedures according to the operator's experience and lesion characteristics. The inconclusive rates of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy were 19% and 4%, respectively (P < .001). The overall accuracy of ultrasonography-guided core needle biopsy for diagnosing malignant tumors was significantly higher than that of ultrasonography-guided fine-needle aspiration (P = .024). The correct tissue-specific diagnosis rates of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy were 95% versus 97% for benign tumors (P = .648) and 67% versus 80% for malignant tumors (P = .310). Trainees showed significantly lower accuracy with ultrasonography-guided fine-needle aspiration than with ultrasonography-guided core needle biopsy for diagnosing malignant tumors (P = .021). There was no difference between the diagnostic accuracy of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy according to the internal composition of the lesions. There were no complications requiring intervention or hospitalization in our patients. Ultrasonography-guided core needle biopsy is superior to ultrasonography-guided fine-needle aspiration in detecting and characterizing malignant tumors of the salivary gland and could emerge as the diagnostic method of choice for patients presenting with a salivary gland mass. © 2015 by American Journal of Neuroradiology.

  3. Emergency ultrasound-guided percutaneous embolization of post-traumatic bleeding hepatic artery pseudoaneurysms.

    PubMed

    Vyas, Sameer; Ahuja, Chirag Kamal; Yadav, Thakur Deen; Khandelwal, Niranjan

    2012-09-01

    Hepatic artery pseudoaneurysm (HAP) is an uncommon but serious complication of blunt trauma abdomen which can be managed by non-surgical interventional methods. We describe the case of a young boy with blunt trauma abdomen having a large hepatic laceration associated with two pseudoaneurysms of the hepatic artery branches. Both these HAPs were successfully managed by percutaneous injection of cyanoacrylate glue under sonographic guidance. A major surgery was thus averted. A brief review of the etiology, diagnosis and management of HAP including the present case is discussed.

  4. Sonography of acne vulgaris.

    PubMed

    Wortsman, Ximena; Claveria, Pedro; Valenzuela, Fernando; Molina, Maria Teresa; Wortsman, Jacobo

    2014-01-01

    The purpose of this study was to assess the sonographic morphology of the clinical and subclinical pathology of facial acne vulgaris. We studied patients with facial acne vulgaris diagnosed by certified dermatologists, and using a standardized protocol for sonographic examinations, we sequentially described the sonographic pathomorphologic characteristics. Lesions of particular interest to the referring clinician were also analyzed separately. Additionally, acne involvement was staged clinically and sonographically (SOS-Acne) using morphologic definitions of the relevant lesions and predefined scoring systems for gradation of the severity of acne lesions. A total of 245 acne lesions in 20 consecutive patients were studied. Sonographic abnormalities consisted of pseudocysts, folliculitis, fistulas, and calcinosis. Most conditions were subclinical and mostly due to lesion extensions deep into the dermis and hypodermis (52% of pseudocysts and 68% of fistulas). The statistical concordance between acne severity scores assigned by two separate clinicians was strong (κ = 0.8020), but the corresponding sonographic scores generally showed more severe and clinically occult involvement. Facial acne vulgaris often involves deeper tissues, beyond the reach of the spatially restricted clinical examination; these subclinical conditions can be detected and defined with sonography. Additionally, acne vulgaris is amenable to sonographic scoring.

  5. Serial Sonographic Assessment of Pulmonary Edema in Patients With Hypertensive Acute Heart Failure.

    PubMed

    Martindale, Jennifer L; Secko, Michael; Kilpatrick, John F; deSouza, Ian S; Paladino, Lorenzo; Aherne, Andrew; Mehta, Ninfa; Conigiliaro, Alyssa; Sinert, Richard

    2018-02-01

    Objective measures of clinical improvement in patients with acute heart failure (AHF) are lacking. The aim of this study was to determine whether repeated lung sonography could semiquantitatively capture changes in pulmonary edema (B-lines) in patients with hypertensive AHF early in the course of treatment. We conducted a feasibility study in a cohort of adults with acute onset of dyspnea, severe hypertension in the field or at triage (systolic blood pressure ≥ 180 mm Hg), and a presumptive diagnosis of AHF. Patients underwent repeated dyspnea and lung sonographic assessments using a 10-cm visual analog scale (VAS) and an 8-zone scanning protocol. Lung sonographic assessments were performed at the time of triage, initial VAS improvement, and disposition from the emergency department. Sonographic pulmonary edema was independently scored offline in a randomized and blinded fashion by using a scoring method that accounted for both the sum of discrete B-lines and degree of B-line fusion. Sonographic pulmonary edema scores decreased significantly from initial to final sonographic assessments (P < .001). The median percentage decrease among the 20 included patient encounters was 81% (interquartile range, 55%-91%). Although sonographic pulmonary edema scores correlated with VAS scores (ρ = 0.64; P < .001), the magnitude of the change in these scores did not correlate with each other (ρ = -0.04; P = .89). Changes in sonographic pulmonary edema can be semiquantitatively measured by serial 8-zone lung sonography using a scoring method that accounts for B-line fusion. Sonographic pulmonary edema improves in patients with hypertensive AHF during the initial hours of treatment. © 2017 by the American Institute of Ultrasound in Medicine.

  6. Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

    PubMed

    Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young

    2017-07-01

    To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P < 0.001). For ultrasound guided-fine needle aspiration, gender, age, size, presence of vascularity, and suspicious US features were not associated with post-biopsy hematoma according to experience level. Post-biopsy hematoma occurred significantly more with ultrasound guided-core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P < 0.001) in experienced performers and ultrasound guided-core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P < 0.001). Post-biopsy hematoma occurred significantly more in ultrasound guided-core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.

  7. Ultrasonographic Findings in 41 Dogs Treated with Bone Marrow Aspirate Concentrate and Platelet-Rich Plasma for a Supraspinatus Tendinopathy: A Retrospective Study

    PubMed Central

    McDougall, Renee A.; Canapp, Sherman O.; Canapp, Debra A.

    2018-01-01

    Objective To report sonographic findings for dogs with a supraspinatus tendinopathy (ST) treated with an ultrasound-guided intratendinous injection of bone marrow aspirate concentrate (BMAC) and platelet-rich plasma (PRP). Methods Medical records for dogs diagnosed with an ST and treated with a BMAC-PRP injection were reviewed. Data collected included patient signalment, radiographic findings at the time of initial evaluation, and sonographic findings, including cross-sectional area (CSA), fiber pattern, and echogenicity. Results Of 70 records reviewed, 41 met the inclusion criteria. Mean CSA of the supraspinatus tendon decreased by 0.06 cm2 between baseline and 45 days post-treatment (p = 0.0025), and 0.09 cm2 between baseline and 90 days post-treatment (p < 0.0001). Analysis of CSA in dogs with a unilateral ST at baseline revealed a difference of 0.08 cm2 between the affected and unaffected tendon at baseline, with the affected tendon measuring larger than the contralateral tendon (p < 0.0001). This difference became statistically insignificant by 45 days after treatment (u1-u0 = 0.04 cm2, p = 0.2855) and remained so 90 days post-treatment (u1-u0 = 0.03 cm2, p = 0.1910). In most cases (90.6%), the fiber pattern and echogenicity was considered improved 90 days post treatment. In a minority of these cases (13.8%) the fiber pattern and echogenicity abnormalities were considered resolved. Conclusions Using qualitative and quantitative sonographic measures, BMAC-PRP was associated with an improvement in supraspinatus tendon size, fiber pattern, and echogenicity. Given the protracted nature of tendon healing, long-term evaluation may reveal continued improvements in chronic structural changes not captured during the current study. Functional studies are required to evaluate the clinical benefits of BMAC-PRP in the treatment of STs in dogs. Clinical significance An ST is a common contributor to forelimb lameness in dogs and remains notoriously difficult to treat. Previous studies have been associated with inconsistent treatment outcomes. In the current study, BMAC-PRP is investigated as a minimally invasive treatment option, revealing positive sonographic results. PMID:29868619

  8. Ultrasonographic Findings in 41 Dogs Treated with Bone Marrow Aspirate Concentrate and Platelet-Rich Plasma for a Supraspinatus Tendinopathy: A Retrospective Study.

    PubMed

    McDougall, Renee A; Canapp, Sherman O; Canapp, Debra A

    2018-01-01

    To report sonographic findings for dogs with a supraspinatus tendinopathy (ST) treated with an ultrasound-guided intratendinous injection of bone marrow aspirate concentrate (BMAC) and platelet-rich plasma (PRP). Medical records for dogs diagnosed with an ST and treated with a BMAC-PRP injection were reviewed. Data collected included patient signalment, radiographic findings at the time of initial evaluation, and sonographic findings, including cross-sectional area (CSA), fiber pattern, and echogenicity. Of 70 records reviewed, 41 met the inclusion criteria. Mean CSA of the supraspinatus tendon decreased by 0.06 cm 2 between baseline and 45 days post-treatment ( p = 0.0025), and 0.09 cm 2 between baseline and 90 days post-treatment ( p < 0.0001). Analysis of CSA in dogs with a unilateral ST at baseline revealed a difference of 0.08 cm 2 between the affected and unaffected tendon at baseline, with the affected tendon measuring larger than the contralateral tendon ( p < 0.0001). This difference became statistically insignificant by 45 days after treatment (u 1 -u 0 = 0.04 cm 2 , p = 0.2855) and remained so 90 days post-treatment (u 1 -u 0 = 0.03 cm 2 , p = 0.1910). In most cases (90.6%), the fiber pattern and echogenicity was considered improved 90 days post treatment. In a minority of these cases (13.8%) the fiber pattern and echogenicity abnormalities were considered resolved. Using qualitative and quantitative sonographic measures, BMAC-PRP was associated with an improvement in supraspinatus tendon size, fiber pattern, and echogenicity. Given the protracted nature of tendon healing, long-term evaluation may reveal continued improvements in chronic structural changes not captured during the current study. Functional studies are required to evaluate the clinical benefits of BMAC-PRP in the treatment of STs in dogs. An ST is a common contributor to forelimb lameness in dogs and remains notoriously difficult to treat. Previous studies have been associated with inconsistent treatment outcomes. In the current study, BMAC-PRP is investigated as a minimally invasive treatment option, revealing positive sonographic results.

  9. Reproducibility of sonographic measurement of thickness and echogenicity of the plantar fascia.

    PubMed

    Cheng, Ju-Wen; Tsai, Wen-Chung; Yu, Tung-Yang; Huang, Kuo-Yao

    2012-01-01

    To evaluate the intra- and interrater reliability of ultrasonographic measurements of the thickness and echogenicity of the plantar fascia. Eleven patients (20 feet), who complained of inferior heel pain, and 26 volunteers (52 feet) were enrolled. Two sonographers independently imaged the plantar fascia in both longitudinal and transverse planes. Volunteers were assessed twice to evaluate intrarater reliability. Quantitative evaluation of the echogenicity of the plantar fascia was performed by measuring the mean gray level of the region of interest using Digital Imaging and Communications in Medicine viewer software. Sonographic evaluation of the thickness of the plantar fascia showed high reliability. Sonographic evaluations of the presence or absence of hypoechoic change in the plantar fascia showed surprisingly low agreement. The reliability of gray-scale evaluations appears to be much better than subjective judgments in the evaluation of echogenicity. Transverse scanning did not show any advantage in sonographic evaluation of the plantar fascia. The reliability of sonographic examination of the thickness of the plantar fascia is high. Mean gray-level analysis of quantitative sonography can be used for the evaluation of echogenicity, which could reduce discrepancies in the interpretation of echogenicity by different sonographers. Longitudinal instead of transverse scanning is recommended for imaging the plantar fascia. Copyright © 2011 Wiley Periodicals, Inc.

  10. An Audit of Second-Trimester Fetal Anomaly Scans Based on a Novel Image-Scoring Method in the Southwest Region of the Netherlands.

    PubMed

    Ursem, Nicolette T C; Peters, Ingrid A; Kraan-van der Est, Mieke N; Reijerink-Verheij, Jacqueline C I Y; Knapen, Maarten F C M; Cohen-Overbeek, Titia E

    2017-06-01

    Since 2007 the second-trimester fetal anomaly scan is offered to all pregnant women as part of the national prenatal screening program in the Netherlands. Dutch population-based screening programs generally have a well-described system to achieve quality assurance. Because of the absence of a uniform system to monitor the actual performance of the fetal anomaly scan in 2012, we developed a standardized image-scoring method. The aim of this study was to evaluate the scanning performance of all sonographers in the southwestern region of the Netherlands using this image-scoring method. Each sonographer was requested to set up a digital portfolio. A portfolio consists of five logbooks from five different pregnant women, each containing 25 fetal anatomical structures and six biometric measures of randomly selected fetal anomaly scans. During the study period, 425 logbooks of 85 sonographers were assessed as part of the audit process. Seventy-three out of 85 sonographers (86%) met the criteria in the primary audit, and 12 sonographers required individual hands-on training. A successful assessment was achieved for 11 sonographers in the re-audit and one sonographer ceased her contract. Moreover, 2.1% of the required images were not digitally stored and therefore could not be reviewed. Quality assessment using the image-scoring method demonstrated that most of the sonographers met the expectations of the audit process, but those who had subpar performance met the expectations after retraining. © 2017 by the American Institute of Ultrasound in Medicine.

  11. Occupational musculoskeletal pain in cardiac sonographers compared to peer employees: a multisite cross-sectional study.

    PubMed

    Orme, Nicholas M; Geske, Jeffrey B; Pislaru, Sorin V; Askew, John Wells; Lennon, Ryan J; Lewis, Bradley R; Rihal, Charanjit S; Pellikka, Patricia A; Singh, Mandeep

    2016-11-01

    The purpose of this study was to compare the prevalence and impact of work-related musculoskeletal pain in cardiac sonographers to a large control group of peer employees with similar demographics. Cardiac sonographers are known to have high levels of occupational musculoskeletal pain. Comparative studies with other employees within cardiology/radiology departments have never been performed. An electronic survey was administered to Mayo Clinic employees at six major patient care facilities in four different states. There were 2682 employees within the departments of cardiology and radiology who were contacted, and 1532 (57%) completed the survey. After excluding those who wore protective lead aprons, 517 employees comprised the control group and 66 cardiac sonographers made up the study group. Cardiac sonographers reported work-related musculoskeletal pain more frequently than the control group (88% vs 40%; P<.001). This association persisted after multivariable adjustment for age, sex, body mass index, length of current employment, and history of preexisting musculoskeletal pain (OR 11.6; [95% CI 5.32, 25.5]; P<.001). Cardiac sonographers sought medical care for their work-related pain more often (55% vs 21%; P<.001) and missed more work due to pain (35% vs 12%, P<.001). In a secondary analysis, cardiac sonographers also experienced more work-related musculoskeletal pain than nurses, technicians, and physicians working in the interventional laboratory who regularly wear a protective lead apron (P<.001). In this multisite cross-sectional study, cardiac sonographers experienced significantly more work-related pain and missed more work due to pain than peer employees within cardiology/radiology departments. © 2016, Wiley Periodicals, Inc.

  12. Swedish Sonographers' perceptions of ergonomic problems at work and their suggestions for improvement.

    PubMed

    Gemark Simonsen, Jenny; Gard, Gunvor

    2016-09-15

    Sonographers' perceptions of ergonomic and work-related pain problems at work have so far mostly been researched in quantitative studies by questionnaires. There is a need of experience-based research to deepen the knowledge about how sonographers perceive ergonomic problems at work. Therefore, the aim of this qualitative study was to describe sonographers' perceptions of ergonomic problems at work, and their suggestions for improvement strategies. Twenty-two female sonographers were individually interviewed regarding different aspects of their physical working environment. Content analysis was applied. The sonographers perceived different ergonomic problems in their working environment, but to offer patient comfort and to obtain the best possible images were often prioritized over working posture. Echocardiography was considered demanding as the examination is performed with little variation in posture. Ergonomic improvements included reducing the manual handling of the transducer, optimizing the adjustability of equipment, and taking the patient's physique and health into account. As some examinations were perceived to be more ergonomically demanding, variation between examinations was suggested, however, this requires broader skills. Sonography, especially echocardiography is ergonomically demanding but the improvement strategies suggested were perceived useful and applicable.

  13. Sonographic Characteristics and Interval Changes of Subacute Thyroiditis.

    PubMed

    Lee, Yoo Jin; Kim, Dong Wook

    2016-08-01

    This study aimed to assess the sonographic characteristics and interval changes of subacute thyroiditis using follow-up sonography. From January 2008 to December 2014, 85 patients with clinically suspected subacute thyroiditis underwent sonographic examinations by a single radiologist. Subacute thyroiditis was confirmed on the basis of the clinical, sonographic, and cytohistopathologic findings. On the initial and follow-up sonograms, the individual sonographic findings and interval changes were retrospectively investigated by the same radiologist. According to the sonographic configuration, subacute thyroiditis lesions were categorized as nodular or non-nodular. The interval changes in the lesions were classified as follows: "disappeared," "decreased," "increased," "eventually smaller," "eventually larger," or "no interval change." Subacute thyroiditis was confirmed in 64 of the 85 patients. In these 64 patients, nodular (n = 39) and non-nodular (n = 35) lesions were found; 10 patients had both nodular and non-nodular lesions. Of the 64 patients, 41 underwent sonographic follow-up. In both nodular and non-nodular lesions, the common interval changes included disappeared, decreased, and eventually smaller patterns. Although the increased pattern was found only in 4 nodular lesions, there was no significant difference in the interval changes between nodular and non-nodular lesions. On follow-up sonography, a new lesion was detected in 6 patients. The prevalence rate of nodular subacute thyroiditis lesions on sonography was high, and the interval changes in the lesions were variable.

  14. Sonographic evaluation of athletic pubalgia.

    PubMed

    Morley, Nicholas; Grant, Thomas; Blount, Kevin; Omar, Imran

    2016-05-01

    Athletic pubalgia, or "sports hernia", represents a constellation of pathologic conditions occurring at and around the pubic symphysis. These injuries are primarily seen in athletes or those involved in athletic activity. In this article, we review the sonographic appearance of the relevant complex anatomy, scanning technique for ultrasound evaluation of athletic pubalgia, and the sonographic appearances of associated pathologic conditions.

  15. Correlation between sonography and antibody activity in patients with Hashimoto thyroiditis.

    PubMed

    Willms, Arnulf; Bieler, Dan; Wieler, Helmut; Willms, Diana; Kaiser, Klaus P; Schwab, Robert

    2013-11-01

    Patients with Hashimoto thyroiditis show structural changes of the thyroid that can be identified by a variety of sonographic criteria. We conducted this study to investigate whether there is a correlation between sonography and antibody activity and to assess the role of sonography in the diagnosis and follow-up of Hashimoto thyroiditis. In addition, we present a new classification system (termed the VESINC system [volume, echogenicity, sonographic texture, pseudonodular hypoechoic infiltration, nodules, and cysts]), which helps improve the clarity of sonographic findings. The study included 223 consecutive patients with previously diagnosed Hashimoto autoimmune thyroiditis who attended the thyroid clinic of the German Armed Forces Central Hospital in Koblenz for follow-up examinations between 2006 and 2008. Laboratory tests were performed to measure the levels of free triiodothyronine, free thyroxine, thyrotropin, anti-thyroglobulin antibodies (TgAbs), and antithyroid peroxidase antibodies (TPOAbs). Sonography was performed according to a strict protocol. We then assessed whether a correlation existed between antibody activity and the 6 sonographic variables of the VESINC system. Hypoechogenicity, heterogeneity, and pseudonodular hypoechoic infiltration were associated with significantly higher TPOAb activity (P < .001). There were no significant correlations between the other sonographic variables examined (cysts, nodules, and volume) or the biometric data with the TPOAb and TgAb levels. In addition, an assessment of TgAb levels did not show significant differences in correlations with any of the sonographic variables. Sonography is a noninvasive diagnostic imaging modality that provides information about the level of inflammatory activity. Markedly decreased echogenicity, heterogeneity, and multifocal pseudoinodular hypoechoic infiltration are indicative of a high level of inflammatory activity. The sonographic classification system presented here (VESINC system) can be a useful tool for comparing sonographic findings in a rapid and objective manner during follow-up of Hashimoto thyroiditis.

  16. Predicting Student Performance in Sonographic Scanning Using Spatial Ability as an Ability Determinent of Skill Acquisition

    ERIC Educational Resources Information Center

    Clem, Douglas Wayne

    2012-01-01

    Spatial ability refers to an individual's capacity to visualize and mentally manipulate three dimensional objects. Since sonographers manually manipulate 2D and 3D sonographic images to generate multi-viewed, logical, sequential renderings of an anatomical structure, it can be assumed that spatial ability is central to the perception and…

  17. Echocardiography service provision in New Zealand: The implications of capacity modelling for the cardiac sonographer workforce.

    PubMed

    Buckley, Belinda; Farnworth, Mark J; Whalley, Gillian

    2016-01-08

    Regional disparity in both utilisation and the cardiac sonographer workforce has previously been identified. We sought to model the capacity of the cardiac sonographer workforce at a national and District Health Board level to better understand these regional differences. In 2013, surveys were distributed to 18 hospitals who employ cardiac sonographers (return rate 100%). Questions related to cardiac sonographer demographics, echo utilisation and workflow. Actual clinical capacity was calculated from scan duration and annual scan volumes. New Zealand national actual capacity was compared to predicted capacity from three international models. Potential clinical capacity was calculated from the workforce size in fulltime equivalent (FTE) and clinical availability. In New Zealand, scan duration and population-based clinical capacity varies between centres. The New Zealand capacity is similar to the UK 30:70 model, and consistently less than the US model for all scan types. There are marked regional differences in potential versus actual capacity, with 10/16 DHBs demonstrating excess potential capacity. There is regional disparity in the capacity of the cardiac sonographer workforce, which appears to be strongly related to scan duration. Workforce capacity modelling should be used with need and demand modelling to plan adequate levels of service provision.

  18. Suspected leaking abdominal aortic aneurysm: use of sonography in the emergency room.

    PubMed

    Shuman, W P; Hastrup, W; Kohler, T R; Nyberg, D A; Wang, K Y; Vincent, L M; Mack, L A

    1988-07-01

    To determine the value of sonography in the emergent evaluation of suspected leaking abdominal aortic aneurysms, the authors examined 60 patients in the emergency department using sonography and a protocol involving advance radio notification from the ambulance; arrival of sonographic personnel and equipment in the triage room before patient arrival; and, during other triage activities, rapid sonographic evaluation of the aorta for aneurysm and of the paraaortic region for extraluminal blood. Sonographic findings were correlated with surgical results and clinical outcome. When performed under these circumstances, sonography was accurate in demonstrating presence or absence of aneurysm (98%), but its sensitivity for extraluminal blood was poor (4%). A combination of sonographic confirmation of aneurysm, abdominal pain, and unstable hemodynamic condition resulted in the correct decision to perform emergent surgery in 21 of 22 patients (95%). An abbreviated sonographic examination done in the emergency room can provide accurate, useful information about the presence of aneurysm; this procedure does not significantly delay triage of these patients.

  19. Student tutors are able to teach basic sonographic anatomy effectively - a prospective randomized controlled trial.

    PubMed

    Celebi, N; Zwirner, K; Lischner, U; Bauder, M; Ditthard, K; Schürger, S; Riessen, R; Engel, C; Balletshofer, B; Weyrich, P

    2012-04-01

    Ultrasound is a widely used diagnostic tool. In medical education, it can be used to teach sonographic anatomy as well as the basics of ultrasound diagnostics. Some medical schools have begun implementing student tutor-led teaching sessions in sonographic abdominal anatomy in order to meet the growing demand in ultrasound teaching. However, while this teaching concept has proven to be feasible and well accepted, there is limited data regarding its effectiveness. We investigated whether student tutors teach sonographic anatomy as effectively as faculty staff sonographers. 50 medical students were randomly assigned to one of two groups. 46 of these could be included in the analysis. One group was taught by student tutors (ST) and the other by a faculty staff sonographer (FS). Using a pre/post-test design, students were required to locate and label 15 different abdominal structures. They printed out three pictures in three minutes and subsequently labeled the structures they were able to identify. The pictures were then rated by two blinded faculty staff sonographers. A mean difference of one point in the improvement of correctly identified abdominal structures between the pre-test and post-test among the two groups was regarded as equivalent. In the pre-test, the ST (FS) correctly identified 1.6 ± 1.0 (2.0 ± 1.1) structures. Both the ST and FS group showed improvement in the post-test, correctly identifying 7.8 ± 2.8 vs. 8.9 ± 2.9 structures, respectively (p < .0001 each). Comparing the improvement of the ST (6.2 ± 2.8 structures) versus the FS (6.9 ± 3.2) showed equivalent results between the two groups (p < .05 testing for equivalence). Basic abdominal sonographic anatomy can be taught effectively by student tutors. © Georg Thieme Verlag KG Stuttgart · New York.

  20. Occupational burnout among radiographers, sonographers and radiologists in Australia and New Zealand: Findings from a national survey.

    PubMed

    Singh, Nabita; Knight, Kellie; Wright, Caroline; Baird, Marilyn; Akroyd, Duane; Adams, Robert D; Schneider, Michal E

    2017-06-01

    Evidence demonstrates that health care professionals are more prone to burnout than other professionals due to the emotionally taxing interactions they have with their patients on a daily basis. The aims of this study were to measure occupational burnout levels among sonographers, radiographers and radiologists and to examine predictors of burnout according to demographic characteristics. A cross-sectional online survey was administered in 2010 to radiographers, sonographers and radiologists who were members of the following professional bodies: Australian Institute of Radiography, Australian Sonographers Association and The Royal Australian and New Zealand College of Radiologists. The Maslach Burnout Inventory was used to measure burnout levels for each profession. Data were analysed using SPSS Ver 20 (IBM, Chicago, IL, USA) statistical software. A total of 613 radiographers, 121 sonographers and 35 radiologists participated in the survey. Radiographers, sonographers and radiologists had a high mean (±SD) burnout score for emotional exhaustion (39.9 ± 8.5, 42.2 ± 8.5 and 44.9 ± 7.1 respectively) and depersonalization (18.9 ± 5.5, 20.3 ± 5.8 and 20.6 ± 5.6) compared to MBI norms. Radiographers also had low personal achievement (30.8 ± 5.5) compared to MBI norms. Radiographers and sonographers who were male, worked >10 hours overtime and spent <10% of their time training students per week had significantly higher depersonalization scores (p < 0.05). Burnout levels among radiographers, sonographers and radiologists are high and likely to vary according to some demographic and work-related factors. Further research is needed to examine ways to alleviate burnout in these professions so that loss of experienced staff due to burnout can be minimized and quality of patient care can be maintained. © 2016 The Royal Australian and New Zealand College of Radiologists.

  1. Likelihood ratio-based differentiation of nodular Hashimoto thyroiditis and papillary thyroid carcinoma in patients with sonographically evident diffuse hashimoto thyroiditis: preliminary study.

    PubMed

    Wang, Liang; Xia, Yu; Jiang, Yu-Xin; Dai, Qing; Li, Xiao-Yi

    2012-11-01

    To assess the efficacy of sonography for discriminating nodular Hashimoto thyroiditis from papillary thyroid carcinoma in patients with sonographically evident diffuse Hashimoto thyroiditis. This study included 20 patients with 24 surgically confirmed Hashimoto thyroiditis nodules and 40 patients with 40 papillary thyroid carcinoma nodules; all had sonographically evident diffuse Hashimoto thyroiditis. A retrospective review of the sonograms was performed, and significant benign and malignant sonographic features were selected by univariate and multivariate analyses. The combined likelihood ratio was calculated as the product of each feature's likelihood ratio for papillary thyroid carcinoma. We compared the abilities of the original sonographic features and combined likelihood ratios in diagnosing nodular Hashimoto thyroiditis and papillary thyroid carcinoma by their sensitivity, specificity, and Youden index. The diagnostic capabilities of the sonographic features varied greatly, with Youden indices ranging from 0.175 to 0.700. Compared with single features, combinations of features were unable to improve the Youden indices effectively because the sensitivity and specificity usually changed in opposite directions. For combined likelihood ratios, however, the sensitivity improved greatly without an obvious reduction in specificity, which resulted in the maximum Youden index (0.825). With a combined likelihood ratio greater than 7.00 as the diagnostic criterion for papillary thyroid carcinoma, sensitivity reached 82.5%, whereas specificity remained at 100.0%. With a combined likelihood ratio less than 1.00 for nodular Hashimoto thyroiditis, sensitivity and specificity were 90.0% and 92.5%, respectively. Several sonographic features of nodular Hashimoto thyroiditis and papillary thyroid carcinoma in a background of diffuse Hashimoto thyroiditis were significantly different. The combined likelihood ratio may be superior to original sonographic features for discrimination of nodular Hashimoto thyroiditis from papillary thyroid carcinoma; therefore, it is a promising risk index for thyroid nodules and warrants further investigation.

  2. [Cardiac sonographers: a unique reality in Anglo-saxon countries? The experience of an Italian echo-lab which is employing them since 1984].

    PubMed

    del Mestre, Lorenzo; Compassi, Rossana; Badano, Luigi P; Monti, Maria Luisa; Ciani, Rosanna; Buiese, Simonetta; Gianfagna, Pasquale; Fioretti, Paolo M

    2006-12-01

    Cardiac sonographers play a key role in the management of echo-laboratories in anglo-saxon countries. In Italy, and generally in "latin" countries nearly all echocardiographic studies are performed by cardiologists. However, because of the increasing demand for echocardiography, this practice will no longer be feasible (medical schools do not graduate enough cardiologists!), and cost-effective (the cost of echocardiography performed by cardiologists only is becoming too high!). Introduction of cardiac sonographers in Italian echo-laboratories may represent a feasible and cost-effective solution to the ever increasing demand for echocardiography. In order to contribute to the debate, we report the experience of our echo-laboratory that employs cardiac sonographers since 1984.

  3. Real-Time, Interactive Echocardiography Over High-Speed Networks: Feasibility and Functional Requirements

    NASA Technical Reports Server (NTRS)

    Bobinsky, Eric A.

    1998-01-01

    Real-time, Interactive Echocardiography Over High Speed Networks: Feasibility and Functional Requirements is an experiment in advanced telemedicine being conducted jointly by the NASA Lewis Research Center, the NASA Ames Research Center, and the Cleveland Clinic Foundation. In this project, a patient undergoes an echocardiographic examination in Cleveland while being diagnosed remotely by a cardiologist in California viewing a real-time display of echocardiographic video images transmitted over the broadband NASA Research and Education Network (NREN). The remote cardiologist interactively guides the sonographer administering the procedure through a two-way voice link between the two sites. Echocardiography is a noninvasive medical technique that applies ultrasound imaging to the heart, providing a "motion picture" of the heart in action. Normally, echocardiographic examinations are performed by a sonographer and cardiologist who are located in the same medical facility as the patient. The goal of telemedicine is to allow medical specialists to examine patients located elsewhere, typically in remote or medically underserved geographic areas. For example, a small, rural clinic might have access to an echocardiograph machine but not a cardiologist. By connecting this clinic to a major metropolitan medical facility through a communications network, a minimally trained technician would be able to carry out the procedure under the supervision and guidance of a qualified cardiologist.

  4. A real-time prediction model for post-irradiation malignant cervical lymph nodes.

    PubMed

    Lo, W-C; Cheng, P-W; Shueng, P-W; Hsieh, C-H; Chang, Y-L; Liao, L-J

    2018-04-01

    To establish a real-time predictive scoring model based on sonographic characteristics for identifying malignant cervical lymph nodes (LNs) in cancer patients after neck irradiation. One-hundred forty-four irradiation-treated patients underwent ultrasonography and ultrasound-guided fine-needle aspirations (USgFNAs), and the resultant data were used to construct a real-time and computerised predictive scoring model. This scoring system was further compared with our previously proposed prediction model. A predictive scoring model, 1.35 × (L axis) + 2.03 × (S axis) + 2.27 × (margin) + 1.48 × (echogenic hilum) + 3.7, was generated by stepwise multivariate logistic regression analysis. Neck LNs were considered to be malignant when the score was ≥ 7, corresponding to a sensitivity of 85.5%, specificity of 79.4%, positive predictive value (PPV) of 82.3%, negative predictive value (NPV) of 83.1%, and overall accuracy of 82.6%. When this new model and the original model were compared, the areas under the receiver operating characteristic curve (c-statistic) were 0.89 and 0.81, respectively (P < .05). A real-time sonographic predictive scoring model was constructed to provide prompt and reliable guidance for USgFNA biopsies to manage cervical LNs after neck irradiation. © 2017 John Wiley & Sons Ltd.

  5. Clinical Effectiveness of Prospectively Reported Sonographic Twinkling Artifact for the Diagnosis of Renal Calculus in Patients Without Known Urolithiasis.

    PubMed

    Masch, William R; Cohan, Richard H; Ellis, James H; Dillman, Jonathan R; Rubin, Jonathan M; Davenport, Matthew S

    2016-02-01

    The purpose of this study was to determine the clinical effectiveness of prospectively reported sonographic twinkling artifact for the diagnosis of renal calculus in patients without known urolithiasis. All ultrasound reports finalized in one health system from June 15, 2011, to June 14, 2014, that contained the words "twinkle" or "twinkling" in reference to suspected renal calculus were identified. Patients with known urolithiasis or lack of a suitable reference standard (unenhanced abdominal CT with ≤ 2.5-mm slice thickness performed ≤ 30 days after ultrasound) were excluded. The sensitivity, specificity, and positive likelihood ratio of sonographic twinkling artifact for the diagnosis of renal calculus were calculated by renal unit and stratified by two additional diagnostic features for calcification (echogenic focus, posterior acoustic shadowing). Eighty-five patients formed the study population. Isolated sonographic twinkling artifact had sensitivity of 0.78 (82/105), specificity of 0.40 (26/65), and a positive likelihood ratio of 1.30 for the diagnosis of renal calculus. Specificity and positive likelihood ratio improved and sensitivity declined when the following additional diagnostic features were present: sonographic twinkling artifact and echogenic focus (sensitivity, 0.61 [64/105]; specificity, 0.65 [42/65]; positive likelihood ratio, 1.72); sonographic twinkling artifact and posterior acoustic shadowing (sensitivity, 0.31 [33/105]; specificity, 0.95 [62/65]; positive likelihood ratio, 6.81); all three features (sensitivity, 0.31 [33/105]; specificity, 0.95 [62/65]; positive likelihood ratio, 6.81). Isolated sonographic twinkling artifact has a high false-positive rate (60%) for the diagnosis of renal calculus in patients without known urolithiasis.

  6. Not all ultrasounds are created equal: general sonography versus musculoskeletal sonography in the detection of rotator cuff tears

    PubMed Central

    Cole, Brandi; Twibill, Kristen; Lam, Patrick; Hackett, Lisa

    2016-01-01

    Background This cross-sectional analytic diagnostic accuracy study was designed to compare the accuracy of ultrasound performed by general sonographers in local radiology practices with ultrasound performed by an experienced musculoskeletal sonographer for the detection of rotator cuff tears. Methods In total, 238 patients undergoing arthroscopy who had previously had an ultrasound performed by both a general sonographer and a specialist musculoskeletal sonographer made up the study cohort. Accuracy of diagnosis was compared with the findings at arthroscopy. Results When analyzed as all tears versus no tears, musculoskeletal sonography had an accuracy of 97%, a sensitivity of 97% and a specificity of 95%, whereas general sonography had an accuracy of 91%, a sensitivity of 91% and a specificity of 86%. When the partial tears were split with those ≥ 50% thickness in the tear group and those < 50% thickness in the no-tear group, musculoskeletal sonography had an accuracy of 97%, a sensitivity of 97% and a specificity of 100% and general sonography had an accuracy of 85%, a sensitivity of 84% and a specificity of 87%. Conclusions Ultrasound in the hands of an experienced musculoskeletal sonographer is highly accurate for the diagnosis of rotator cuff tears. General sonography has improved subsequent to earlier studies but remains inferior to an ultrasound performed by a musculoskeletal sonographer. PMID:27660657

  7. Academic physicians' opinions on preliminary reporting of echocardiographic data.

    PubMed

    McDonald, R W; Rice, M J; Reller, M D; Silberbach, G M; Imus, R L; Marcella, C P; Brazee, R B; Pantely, G A

    1993-01-01

    Preliminary reporting of echocardiographic data by cardiac sonographers has become a key issue in the echocardiography community. A survey on this issue was sent to 248 academic physicians and 89 (35.8%) were returned. In response to a question in the survey, 76 physicians stated that they had at least a limited amount of knowledge in echocardiography. For the group, 62% wanted a written or verbal preliminary report and 52% concluded that this report should be a part of the cardiac sonographer's position. If cardiac abnormalities are suspected, 65% wanted the results before the cardiologist reviewed the study, but only 42% of the physicians wanted a diagnostic versus a descriptive type of report. About 49% stated that if necessary they would attempt to influence the cardiac sonographer to give them a preliminary report, whereas 67% of the physicians would possibly use this information to medically manage the patient. Fifty percent believed that it was legal for a cardiac sonographer to give a preliminary report. Another 70% said that the cardiac sonographer would NOT be "practicing medicine without a license" and 66% concluded that they would NOT be "aiding and abetting the unauthorized practice of medicine" if given this information. These data have important potential ramifications for both cardiac sonographers as well as for the practice of cardiology regarding the issue of preliminary echocardiographic reports.

  8. Sonographic demonstration of stomach pathology: Reviewing the cases

    PubMed Central

    2015-01-01

    Abstract Introduction: The stomach can be the source of complaints for many patients attending for upper abdominal ultrasound. It is not routinely imaged as part of most upper abdominal ultrasound protocols, with sonographers and sonologists alike commonly muttering the line; “I can't see the stomach on ultrasound”. However, this is incorrect, as the gastric antrum can almost always be visualised sonographically. Discussion: It is possible to detect a range of pathologies affecting the stomach sonographically, from common, largely tolerable conditions such as hiatus hernias through to life‐threatening neoplasms. Conclusion: The stomach can easily be assessed during routine abdominal ultrasound providing the sonographer has knowledge of stomach anatomy, normal ultrasound appearances and limitations to its visualisation. While endoscopy is the gold standard for investigation of the stomach and upper gastrointestinal tract, many patients will initially present for abdominal ultrasound due to its easy, non‐invasive nature, ready availability and low cost. For patients with mild abdominal symptoms, a normal abdominal ultrasound may be the extent of their imaging investigations meaning stomach pathologies may go undiagnosed. PMID:28191199

  9. Abdominal cocoon: sonographic features.

    PubMed

    Vijayaraghavan, S Boopathy; Palanivelu, Chinnusamy; Sendhilkumar, Karuppusamy; Parthasarathi, Ramakrishnan

    2003-07-01

    An abdominal cocoon is a rare condition in which the small bowel is encased in a membrane. The diagnosis is usually established at surgery. Here we describe the sonographic features of this condition.

  10. The transverse technique; a complementary approach to the measurement of first-trimester uterine artery Doppler.

    PubMed

    Drouin, Olivier; Johnson, Jo-Ann; Chaemsaithong, Piya; Metcalfe, Amy; Huber, Janie; Schwarzenberger, Jill; Winters, Erin; Stavness, Lesley; Tse, Ada W T; Lu, Jing; Lim, Wan Teng; Leung, Tak Yeung; Bujold, Emmanuel; Sahota, Daljit; Poon, Liona C

    2017-10-04

    The objectives of this study were to 1) define the protocol for the first-trimester assessment of the uterine artery pulsatility index (UtA-PI) using the new transverse technique, 2) evaluate UtA-PI measured by the transverse approach versus that obtained by the conventional sagittal approach, and 3) determine if accelerated onsite training (both methods) of inexperienced sonographers can achieve reproducible UtA-PI measurements compared to that measured by an experienced sonographer. The study consists of 2 parts conducted in 2 centers (Part 1, Calgary, Canada and Part 2, Hong Kong). Part 1 Prospective observational study of women with singleton pregnancies between 11-13+6 weeks' gestation. UtA-PI measurements were performed using the 2 techniques (4 sonographers trained in both methods, 10 cases each) and measurement indices (PI), time required and subjective difficulty to obtain satisfactory measurements were compared. One sample t-test and Wilcoxon rank sign test was used when appropriate. Bland-Altman difference plots were used to assess measurement agreement, and intra-class correlation (ICC) was used to evaluate measurement reliability. A target plot was used to assess measures of central tendency and dispersion. Part 2 One experienced and three inexperienced sonographers prospectively measured the UtA-PI at 11-13+6 weeks' gestation in two groups of women (42 and 35, respectively), with singleton pregnancies using both approaches. Inexperienced sonographers underwent accelerated on-site training by the experienced sonographer. Measurement approach and sonographer order were on a random basis. ICC, Bland-Altman and Passing-Bablok analyses were performed to assess measurement agreement, reliability and effect of accelerated training. Part 1 We observed no difference in the mean time to acquire the measurements (Sagittal: 118 seconds vs Transverse: 106 seconds, p=0.38). The 4 sonographers reported the transverse technique was subjectively easier to perform (p=0.04). The bias (95% LOA) and the ICC between sagittal and transverse measurements was -0.05 (-0.48 to 0.37) and 0.94 for the mean UtA-PIs respectively. Measurements obtained using the transverse technique after correcting for gestation were significantly closer to the expected distribution than the sagittal technique. Part 2 There were no significant differences in the median UtA-PI measurements using the different approaches for both experienced and inexperienced sonographers (p>0.05 for all sonographers). Mean UtA-PI measurement reliability between approaches was high for the experienced (ICC=0.92) and inexperienced sonographers (ICC>0.81). UtA-PI measurement approaches did not deviate from linearity whilst biases ranged from -0.10 to 0.07. Median time required was similar (sagittal vs. transverse: 56.11 sec vs. 49.29 sec; p=0.054). This novel transverse approach for the measurement of UtA-PI in the first-trimester appears comparable to the sagittal approach and can be used in first-trimester preeclampsia screening. Providing accelerated onsite training can be helpful to improve UtA-PI measurement reliability and could potentially facilitate the broad implementation of first-trimester preeclampsia screening. This article is protected by copyright. All rights reserved.

  11. Developing a virtual community for health sciences library book selection: Doody's Core Titles.

    PubMed

    Shedlock, James; Walton, Linda J

    2006-01-01

    The purpose of this article is to describe Doody's Core Titles in the Health Sciences as a new selection guide and a virtual community based on an effective use of online systems and to describe its potential impact on library collection development. The setting is the availability of health sciences selection guides. Participants include Doody Enterprise staff, Doody's Library Board of Advisors, content specialists, and library selectors. Resources include the online system used to create Doody's Core Titles along with references to complementary databases. Doody's Core Titles is described and discussed in relation to the literature of selection guides, especially in comparison to the Brandon/Hill selected lists that were published from 1965 to 2003. Doody's Core Titles seeks to fill the vacuum created when the Brandon/Hill lists ceased publication. Doody's Core Titles is a unique selection guide based on its method of creating an online community of experts to identify and score a core list of titles in 119 health sciences specialties and disciplines. The result is a new selection guide, now available annually, that will aid health sciences librarians in identifying core titles for local collections. Doody's Core Titles organizes the evaluation of core titles that are identified and recommended by content specialists associated with Doody's Book Review Service and library selectors. A scoring mechanism is used to create the selection of core titles, similar to the star rating system employed in other Doody Enterprise products and services.

  12. Regional differences in echocardiography provision in New Zealand--results from the 2013 SCANZ Workforce Survey.

    PubMed

    Buckley, Belinda A; Poppe, Katrina; Farnworth, Mark J; Whalley, Gillian

    2015-01-30

    Abstract Healthcare may be unevenly distributed based on geographic location. This study aimed to identify whether regional differences in echocardiography provision exist and, if so, to explore key causes. In March 2013, 18 public hospitals with a sonographer-led echocardiography service were surveyed, all of which provided data. Questions related to characteristics of the sonographer workforce, echocardiogram volumes and workflows. Information on District Health Board (DHB) population was obtained from public access websites. Multivariable linear regression was performed using the following variables: ethnicity, age, socioeconomic status, type of centre, sonographer full-time equivalent (FTE) and number/proportion of trainees to determine their potential contribution to echocardiogram volume. 1748 echocardiograms were performed per 100,000 population (mean) with significant differences seen amongst DHBs but not between tertiary surgical and regional centres (surgical median 1802, regional median 1658, p=0.18). Regional disparity in the population-based cardiac sonographer workforce size was observed and the number of scans performed per sonographer was higher in larger centres. In multivariable modelling, the DHB population-based scan volume was predicted by: socioeconomic status (top two quintiles of deprivation status increased scans by 75 per 100,000 population, p=0.02) and age (age 20 to 65 years increased scans by 131 per 100,000 population, p=0.06). Regional differences in echocardiography services in New Zealand exist as evidenced by marked regional disparity in both population-based echo volumes and cardiac sonographer workforce size.

  13. Sonographic Features of Nodular Hashimoto Thyroiditis.

    PubMed

    Oppenheimer, Daniel Corey; Giampoli, Ellen; Montoya, Simone; Patel, Swapnil; Dogra, Vikram

    2016-09-01

    The aim of the study was to analyze the sonographic features of nodular Hashimoto thyroiditis (HT) in patients with diffuse background thyroiditis and normal background thyroid parenchyma. Eighty-six patients who had fine-needle aspiration biopsy of 100 thyroid nodules confirmed to be HT and a thyroid ultrasound within 1 year of the biopsy were included in the study. Retrospective analysis of several sonographic features of each nodule was then performed. The mean age of patients with nodular HT was 53 years, 84% of which were female. Nodular HT occurred in a background of diffuse thyroiditis in 85% and in a homogeneous normal background in 15%. Ninety-three percent of nodules were completely solid and 7% of nodules were cystic and solid. Although the sonographic appearance of nodular HT was variable, the most common appearance was a solid (93/100) and hypoechoic nodule (44/100) with a thin hypoechoic halo (42/100) without calcifications (96/100). On color Doppler, 17% of nodules showed peripheral hypervascularity, 14% of nodules were diffusely hypervascular, 34% were iso vascular, 32% were hypovascular, and 3% were avascular. The sonographic appearance of nodular HT was not significantly different in patients with diffuse background thyroiditis compared with those without background thyroiditis. The sonographic appearance of nodular HT is variable, but the most common appearance is a solid sharply circumscribed hypoechoic nodule with thin hypoechoic halo without calcification. There was no significant difference in the appearance of nodular HT in patients with diffuse background thyroiditis compared with patients with normal background thyroid parenchyma.

  14. Sigmoid stenosis caused by diverticulitis vs. carcinoma: usefulness of sonographic features for their differentiation in the emergency setting.

    PubMed

    Ripollés, Tomás; Martínez-Pérez, María Jesús; Gómez Valencia, Diana Patricia; Vizuete, José; Martín, Gregorio

    2015-10-01

    To retrospectively evaluate the accuracy of ultrasound as a diagnostic method for differentiating acute diverticulitis from colon cancer in patients with sigmoid colon stenosis. Ultrasound examinations of 91 consecutive patients with sigmoid stenosis (50 diverticulitis and 41 colon cancers) were reviewed by two trained radiologists. Sixty-five (71%) patients presented with acute abdominal symptoms. Thirteen sonographic criteria retrieved from the literature were evaluated to differentiate benign from malignant strictures. A score including all parameters which showed significant differences between benign vs. malignant was built. Sensitivity, specificity, accuracy, and positive or negative predictive values of each sonographic sign, the overall diagnosis, and sonographic score were calculated. Loss of the bowel wall stratification was the most reliable criteria for the diagnosis of malignancy (92% and 94% of sensitivity and specificity, respectively), and the best inter-radiologist agreement (κ = 0.848). Adjacent lymph nodes were the most specific feature (98%) for colon cancer, but its sensitivity was low. Global assessment could differentiate both diseases with high sensitivity (92-94.9%) and specificity (98-100%). Sonographic score >3 enabled differentiation of carcinoma from diverticulitis with 95% sensitivity and 92-94% specificity, with an area under the ROC curve of 0.98-0.987. There were no significant differences in the results between patients with acute and nonacute abdominal symptoms. The combination of several morphological sonographic findings using a score can differentiate most cases of diverticulitis from colon carcinoma in sigmoid strictures.

  15. The prevalence of work-related musculoskeletal disorders among sonographers.

    PubMed

    Al-Rammah, Tamader Y; Aloufi, Areej S; Algaeed, Saffana K; Alogail, Noura S

    2017-01-01

    Work-related musculoskeletal disorders (WRMSDs) have a significant effect on the psychological and physical function of the sonographer. This study is concerned about finding the prevalence of WRMSDs among sonographers in the Kingdom of Saudi Arabia and assessing how to improve future practices and develop guidelines for safe, pain-free ultrasound departments. A survey was distributed to sonographers working in major hospitals in Riyadh, Saudi Arabia (n = 100, 83% response rate). The questionnaire focused on workload and ergonomics, pain existence and history, and the level of the sonographers' awareness of prevention measures and best practices. Ethical approval was obtained from a local Institutional Review Board. Eighty-four percent of respondents suffer from pain they associated with their ultrasound practice. The shoulder, back, neck and right hand were the main symptomatic body areas. Low levels of awareness about best practices and safety measures were revealed. There was a strong correlation between the degree of pain suffered and the years of practice, the number of patients scanned per day, and movements during the exam. Implementing standards and guidelines for best ultrasound practices is needed to develop better and safer ultrasound departments in Saudi hospitals for every practitioner.

  16. Ossification center of the infant hip: sonographic and radiographic correlation.

    PubMed

    Harcke, H T; Lee, M S; Sinning, L; Clarke, N M; Borns, P F; MacEwen, G D

    1986-08-01

    A new sonographic technique for evaluating the ossification center of the infant's hip allowed identification of the ossific nucleus before it could be visualized radiographically. With this technique, delay in ossification associated with hip pathology can also be recognized. Proper assessment of the size of the ossific nucleus requires scanning in orthogonal planes. Acoustic shadowing causes the growing ossification center to appear curved and may make the medial acetabulum and triradiate cartilage difficult to identify. Sonographic hip evaluation usually ceases to be reliable in children over 1 year old.

  17. Ultrasonography of hydronephrosis in the newborn: a practical review

    PubMed Central

    2016-01-01

    Widespread use of fetal ultrasonography is accompanied by more frequent detection of antenatal hydronephrosis. Therefore, sonographic evaluation of neonates with a history of antenatal hydronephrosis is becoming more widespread. As an initial postnatal non-invasive imaging modality, ultrasonography is used to screen for persistence of hydronephrosis, determine the level and severity of obstruction, and contribute to appropriate diagnosis and treatment. This review aims to provide a practical overview of the sonographic evaluation of neonatal hydronephrosis and to describe the sonographic findings of conditions associated with hydronephrosis in the newborn. PMID:27156562

  18. Prenatal sonographic patterns in six cases of Wolf-Hirschhorn (4p-) syndrome.

    PubMed

    Boog, Georges; Le Vaillant, Claudine; Collet, Michel; Dupré, Pierre François; Parent, Philippe; Bongain, André; Benoit, Bernard; Trastour, Claire

    2004-01-01

    This multicentric study presents 6 cases of Wolf-Hirschhorn syndrome (deletion of 4p) detected after a sonographic prenatal diagnosis of early intrauterine growth retardation with fetal abnormalities. Standard karyotyping on regular G-banding during pregnancy was normal in half of the cases. Fortunately, the associated sonographic signs of a typical face, cystic cerebral lesions, midline fusion defects and bilateral renal hypoplasia may help to refine specific indications for high-resolution banding and molecular analysis by in situ hybridization. Copyright 2004 S. Karger AG, Basel

  19. Developmental dysplasia of the hip: impact of sonographic newborn hip screening on the outcome of early treated decentered hip joints-a single center retrospective comparative cohort study based on Graf's method of hip ultrasonography.

    PubMed

    Tschauner, Christian; Fürntrath, Frank; Saba, Yasaman; Berghold, Andrea; Radl, Roman

    2011-12-01

    PURPOSE/BACKGROUND/INTRODUCTION: The aim of this study was to retrospectively evaluate the impact of neonatal sonographic hip screening using Graf's method for the management and outcome of orthopaedic treatment of decentered hip joints with developmental dysplasia of the hip (DDH), using three decades (1978-2007) of clinical information compiled in a medical database. Three representative cohorts of consecutive cases of decentered hip joints were selected according to different search criteria and inclusion and exclusion parameters: (1) cohort 1 (1978-1982; n = 80), without sonographic screening; (2) cohort 2.1 (1994-1996; n = 91), with nationwide established general sonographic screening according to the Graf-method; (3) cohort 2.2 (2003-2005; n = 91), with sonographic screening including referred cases for open reduction from non-screened populations. These three cohorts were compared for the following parameters: age at initial treatment, successful closed reduction, necessary overhead traction, necessary adductor-tenotomy, rate of open reduction, rate of avascular necrosis (AVN) and rate of secondary acetabuloplasty. The age at initial treatment was reduced from 5.5 months in the first cohort to 2 months in the two subsequent two cohorts and the rate of successful closed reduction increased from 88.7 to 98.9 and 95.6%, respectively. There was a statistically significant improvement in six out of seven parameters with sonographic hip screening; only the rate of secondary acetabuloplasty did not improve significantly. Compared to the era before the institution of a sonographic hip screening programme according to the Graf-method in Austria in 1992, ultrasound screening based-treatment of decentered hip joints has become safer, shorter and simpler: "safer" means lower rate of AVN, "shorter" means less treatment time due to earlier onset and "simpler" means that the devices are now less invasive and highly standardized.

  20. Prevalence of work-related musculoskeletal disorders among sonographers in China: results from a national web-based survey

    PubMed Central

    Zhang, Danying; Huang, Hanlin

    2017-01-01

    Objectives: The aims of present study were to determine the prevalence of work-related musculoskeletal disorders (WRMSDs) among sonographers in China and to provide evidence for appropriate intervention measures to be taken. Methods: A self-reported questionnaire was used to screen WRMSDs experienced by sonographers during the past 12 months. This questionnaire survey was created and hosted on the WeChat official account platform for sonographers. Results: In the present study, 567 sonographers from 521 medical institutions completed the questionnaire. The vast majority (99.3%) of respondents reported experiencing symptoms of WRMSDs for at least one body region during the past 12 months. Work-related musculoskeletal pain or discomfort was most frequently reported for the neck (95.1%), right shoulder (84.1%), lower back (82.4%), right wrist/hand (81.0%), upper back (78.1%), right forearm/elbow (72.0%), and left shoulder (66.1%). Scanning hours per day, number of patients per day, and years of experience were positively associated with the occurrence and frequency of experiencing WRMSDs of some common and specific anatomical regions. Taking a regular rest break during the scanning working day was associated with a reduction of WRMSDs of the right shoulder and right wrist/hand. Adopting a sitting posture while performing scanning was associated with a reduction of WRMSDs, particularly for the lower back and the neck. Performing regular physical activity during leisure time was associated with a reduction of WRMSDs of the neck. Conclusions: The prevalence of WRMSDs among sonographers in China was extremely high. It is necessary and essential to reduce the number of scanning hours and patients per day, adopt a sitting posture while performing scanning, schedule regular rest breaks during the scanning working day, and encourage performance of regular physical activity during leisure time to alleviate this WRMSD issue experienced by sonographers. PMID:28904258

  1. The prevalence and clinical significance of sonographic tendon abnormalities in asymptomatic ballet dancers: a 24-month longitudinal study.

    PubMed

    Comin, Jules; Cook, Jill L; Malliaras, Peter; McCormack, Moira; Calleja, Michelle; Clarke, Andrew; Connell, David

    2013-01-01

    Sonographic abnormalities of the achilles and patellar tendons are common findings in athletes, and tendinopathy is a common cause of pain and disability in athletes. However, it is unclear whether the sonographic changes are pathological or adaptive, or if they predict future injury. We undertook a cohort study to determine what sonographic features of the achilles and patellar tendons are consistent with changes as a result of ballet training, and which may be predictive of future development of disabling tendon symptoms. The achilles and patellar tendons of 79 (35 male, 44 female) professional ballet dancers (members of the English Royal Ballet) were examined with ultrasound, measuring proximal and distal tendon diameters and assessing for the presence of hypoechoic change, intratendon defects, calcification and neovascularity. All subjects were followed for 24 months for the development of patellar tendon or achilles-related pain or injury severe enough to require time off from dancing. Sonographic abnormalities were common among dancers, both male and female, and in both achilles and patellar tendons. Disabling tendon-related symptoms developed in 10 dancers and 14 tendons: 7 achilles (3 right, 4 left) and 7 patellar (2 right, 5 left). The presence of moderate or severe hypoechoic defects was weakly predictive for the development of future disabling tendon symptoms (p=0.0381); there was no correlation between any of the other sonographic abnormalities and the development of symptoms. There was no relationship between achilles or patellar tendons' diameter, either proximal or distal, with an increased likelihood of developing tendon-related disability. The presence of sonographic abnormalities is common in ballet dancers, but only the presence of focal hypoechoic changes predicts the development of future tendon-related disability. This suggests that screening of asymptomatic individuals may be of use in identifying those who are at higher risk of developing tendon-related disability, which may in turn allow targeted modifications of training or other preventative regimens.

  2. Prevalence of work-related musculoskeletal disorders among sonographers in China: results from a national web-based survey.

    PubMed

    Zhang, Danying; Huang, Hanlin

    2017-11-25

    The aims of present study were to determine the prevalence of work-related musculoskeletal disorders (WRMSDs) among sonographers in China and to provide evidence for appropriate intervention measures to be taken. A self-reported questionnaire was used to screen WRMSDs experienced by sonographers during the past 12 months. This questionnaire survey was created and hosted on the WeChat official account platform for sonographers. In the present study, 567 sonographers from 521 medical institutions completed the questionnaire. The vast majority (99.3%) of respondents reported experiencing symptoms of WRMSDs for at least one body region during the past 12 months. Work-related musculoskeletal pain or discomfort was most frequently reported for the neck (95.1%), right shoulder (84.1%), lower back (82.4%), right wrist/hand (81.0%), upper back (78.1%), right forearm/elbow (72.0%), and left shoulder (66.1%). Scanning hours per day, number of patients per day, and years of experience were positively associated with the occurrence and frequency of experiencing WRMSDs of some common and specific anatomical regions. Taking a regular rest break during the scanning working day was associated with a reduction of WRMSDs of the right shoulder and right wrist/hand. Adopting a sitting posture while performing scanning was associated with a reduction of WRMSDs, particularly for the lower back and the neck. Performing regular physical activity during leisure time was associated with a reduction of WRMSDs of the neck. The prevalence of WRMSDs among sonographers in China was extremely high. It is necessary and essential to reduce the number of scanning hours and patients per day, adopt a sitting posture while performing scanning, schedule regular rest breaks during the scanning working day, and encourage performance of regular physical activity during leisure time to alleviate this WRMSD issue experienced by sonographers.

  3. Needle tract implantation of hepatoblastoma after percutaneous needle biopsy: report of a case.

    PubMed

    Sumiyoshi, Tatsuaki; Shima, Yasuo; Nishiuchi, Ritsuo; Sasaki, Kiyoshi; Kouzuki, Akihito; Noda, Yoshihiro; Hata, Yasuhiro; Uka, Kiminobu

    2014-06-01

    A 13-year-old boy was referred to us for investigation of a giant liver mass, approximately 16 cm in diameter. Sonographically guided percutaneous needle biopsy was performed and histological examination revealed a fetal-type hepatoblastoma. After four courses of chemotherapy, we performed a left hepatic trisegmentectomy. Follow-up computed tomography, 55 months after the surgery, showed a 1-cm tumor on the route of the preoperative needle biopsy. A second laparotomy revealed a peritonealised tumor, which was excised. The histology of this tumor was identical to that of the primary hepatoblastoma. To our knowledge, this is only the second report of needle tract implantation of hepatoblastoma after percutaneous needle biopsy.

  4. Developing a virtual community for health sciences library book selection: Doody's Core Titles

    PubMed Central

    Shedlock, James; Walton, Linda J.

    2006-01-01

    Purpose: The purpose of this article is to describe Doody's Core Titles in the Health Sciences as a new selection guide and a virtual community based on an effective use of online systems and to describe its potential impact on library collection development. Setting/Participants/Resources: The setting is the availability of health sciences selection guides. Participants include Doody Enterprise staff, Doody's Library Board of Advisors, content specialists, and library selectors. Resources include the online system used to create Doody's Core Titles along with references to complementary databases. Brief Description: Doody's Core Titles is described and discussed in relation to the literature of selection guides, especially in comparison to the Brandon/Hill selected lists that were published from 1965 to 2003. Doody's Core Titles seeks to fill the vacuum created when the Brandon/Hill lists ceased publication. Doody's Core Titles is a unique selection guide based on its method of creating an online community of experts to identify and score a core list of titles in 119 health sciences specialties and disciplines. Results/Outcome: The result is a new selection guide, now available annually, that will aid health sciences librarians in identifying core titles for local collections. Evaluation Method: Doody's Core Titles organizes the evaluation of core titles that are identified and recommended by content specialists associated with Doody's Book Review Service and library selectors. A scoring mechanism is used to create the selection of core titles, similar to the star rating system employed in other Doody Enterprise products and services. PMID:16404471

  5. Sonographic features of invasive ductal breast carcinomas predictive of malignancy grade.

    PubMed

    Gupta, Kanika; Kumaresan, Meenakshisundaram; Venkatesan, Bhuvaneswari; Chandra, Tushar; Patil, Aruna; Menon, Maya

    2018-01-01

    Assessment of individual sonographic features provides vital clues about the biological behavior of breast masses and can assist in determining histological grade of malignancy and thereby prognosis. Assessment of individual sonographic features of biopsy proven invasive ductal breast carcinomas as predictors of malignancy grade. A retrospective analysis of sonographic findings of 103 biopsy proven invasive ductal breast carcinomas. Tumor characteristics on gray-scale ultrasound and color flow were assessed using American College of Radiology (ACR) Breast Imaging Reporting and Data System (BI-RADS) Atlas Fifth Edition. The sonographic findings of masses were individually correlated with their histopathologic grades. Chi square test, ordinal regression, and Goodman and Kruskal tau test. Breast mass showing reversal/lack of diastolic flow has a high probability of belonging to histological high grade tumor ( β 1.566, P 0.0001 ). The masses with abrupt interface boundary are more likely grade 3 ( β 1.524, P 0.001 ) in comparison to masses with echogenic halos. The suspicious calcifications present in and outside the mass is a finding associated with histologically high grade tumors. The invasive ductal carcinomas (IDCs) with complex solid and cystic echotexture are more likely to be of high histological grade ( β 1.146, P 0.04 ) as compared to masses with hypoechoic echotexture. Certain ultrasound features are associated with tumor grade on histopathology. If the radiologist is cognizant of these sonographic features, ultrasound can be a potent modality for predicting histopathological grade of IDCs of the breast, especially in settings where advanced tests such as receptor and molecular analyses are limited.

  6. Hashimoto thyroiditis: Part 1, sonographic analysis of the nodular form of Hashimoto thyroiditis.

    PubMed

    Anderson, Lauren; Middleton, William D; Teefey, Sharlene A; Reading, Carl C; Langer, Jill E; Desser, Terry; Szabunio, Margaret M; Hildebolt, Charles F; Mandel, Susan J; Cronan, John J

    2010-07-01

    The purpose of this article is to analyze the sonographic appearance of nodular Hashimoto thyroiditis. As part of an ongoing multiinstitutional study, patients who underwent ultrasound examination and fine-needle aspiration of one or more thyroid nodules were analyzed for multiple predetermined sonographic features. Patients completed a questionnaire, including information about thyroid function and thyroid medication. Patients (n = 61) with fine-needle aspiration cytologic results consistent with nodular Hashimoto thyroiditis (n = 64) were included in the study. The mean (+/- SD) diameter of nodular Hashimoto thyroiditis was 15 +/- 7.33 mm. Nodular Hashimoto thyroiditis occurred as a solitary nodule in 36% (23/64) of cases and in the setting of five or more nodules in 23% (15/64) of cases. Fifty-five percent (35/64) of the cases of nodular Hashimoto thyroiditis occurred within a sonographic background of diffuse Hashimoto thyroiditis, and 45% (29/64) of cases occurred within normal thyroid parenchyma. The sonographic appearance was extremely variable. It was most commonly solid (69% [42/61] of cases) and hypoechoic (47% [27/58] of cases). Twenty percent (13/64) of nodules had calcifications (seven with nonspecific bright reflectors, four with macrocalcifications, and three eggshell), and 5% (3/64) of nodules had colloid. Twenty-seven percent (17/64) of nodules had a hypoechoic halo. The margins were well defined in 60% (36/60) and ill defined in 40% (24/60) of nodules. On Doppler analysis, 35% (22/62) of nodules were hypervascular, 42% (26/62) were isovascular or hypovascular, and 23% (14/62) were avascular. The sonographic features and vascularity of nodular Hashimoto thyroiditis were extremely variable.

  7. Image guidance improves localization of sonographically occult colorectal liver metastases

    NASA Astrophysics Data System (ADS)

    Leung, Universe; Simpson, Amber L.; Adams, Lauryn B.; Jarnagin, William R.; Miga, Michael I.; Kingham, T. Peter

    2015-03-01

    Assessing the therapeutic benefit of surgical navigation systems is a challenging problem in image-guided surgery. The exact clinical indications for patients that may benefit from these systems is not always clear, particularly for abdominal surgery where image-guidance systems have failed to take hold in the same way as orthopedic and neurosurgical applications. We report interim analysis of a prospective clinical trial for localizing small colorectal liver metastases using the Explorer system (Path Finder Technologies, Nashville, TN). Colorectal liver metastases are small lesions that can be difficult to identify with conventional intraoperative ultrasound due to echogeneity changes in the liver as a result of chemotherapy and other preoperative treatments. Interim analysis with eighteen patients shows that 9 of 15 (60%) of these occult lesions could be detected with image guidance. Image guidance changed intraoperative management in 3 (17%) cases. These results suggest that image guidance is a promising tool for localization of small occult liver metastases and that the indications for image-guided surgery are expanding.

  8. Optical fibers and Fluorosensors having improved power efficiency and methods of producing same

    NASA Technical Reports Server (NTRS)

    Egalon, Claudio O. (Inventor); Rogowski, Robert S. (Inventor)

    1993-01-01

    Optical fibers may have applications including fluorosensors which sense the concentration of an analyte. Like communication fibers, these fluorosensors are modeled using a weakly guiding approximation which is only effective when the difference between the respective refractive indices of the fiber core and surrounding cladding are minimal. An optical fiber fluorosensor is provided having a portion of a fiber core which is surrounded by an active cladding which is permeable by the analyte to be sensed and containing substances which emit light waves upon excitation. A remaining portion of the fiber core is surrounded by a guide cladding which guides these light waves to a sensor which detects the intensity of waves, which is a function of the analyte concentration. Contrary to conventional weakly guiding principles, the difference between the respective indices of refraction of the fiber core is surrounded by an active cladding which is thin enough such that its index of refraction is effectively that of the surrounding atmosphere, thereby the atmosphere guides the injective indices of the fiber core and the cladding results in an unexpected increase in the power efficiency of the fiber core.

  9. Sonographic Examination of The Fetus Vis-à-Vis Shoulder Dystocia: A Vexing Promise.

    PubMed

    Doty, Morgen S; Al-Hafez, Leen; Chauhan, Suneet P

    2016-12-01

    Since antepartum and intrapartum risk factors are poor at identifying women whose labor is complicated by shoulder dystocia, sonographic examination of the fetus holds promise. Though there are several measurements of biometric parameters to identify the parturient who will have shoulder dystocia, none are currently clinically useful. Three national guidelines confirm that sonographic measurements do not serve as appropriate diagnostic tests to identify women who will have shoulder dystocia with or without concurrent injury. In summary, biometric measurements of the fetus should not be used to alter clinical management with the aim of averting shoulder dystocia.

  10. Method for automatically scramming a nuclear reactor

    DOEpatents

    Ougouag, Abderrafi M.; Schultz, Richard R.; Terry, William K.

    2005-12-27

    An automatically scramming nuclear reactor system. One embodiment comprises a core having a coolant inlet end and a coolant outlet end. A cooling system operatively associated with the core provides coolant to the coolant inlet end and removes heated coolant from the coolant outlet end, thus maintaining a pressure differential therebetween during a normal operating condition of the nuclear reactor system. A guide tube is positioned within the core with a first end of the guide tube in fluid communication with the coolant inlet end of the core, and a second end of the guide tube in fluid communication with the coolant outlet end of the core. A control element is positioned within the guide tube and is movable therein between upper and lower positions, and automatically falls under the action of gravity to the lower position when the pressure differential drops below a safe pressure differential.

  11. The effect of chair massage on muscular discomfort in cardiac sonographers: a pilot study

    PubMed Central

    2010-01-01

    Background Cardiac sonographers frequently have work-related muscular discomfort. We aimed to assess the feasibility of having sonographers receive massages during working hours in an area adjacent to an echocardiography laboratory and to assess relief of discomfort with use of the massages with or without stretching exercises. Methods A group of 45 full-time sonographers was randomly assigned to receive weekly 30-minute massage sessions, massages plus stretching exercises to be performed twice a day, or no intervention. Outcome measures were scores of the QuickDASH instrument and its associated work module at baseline and at 10 weeks of intervention. Data were analyzed with standard descriptive statistics and the separation test for early-phase comparative trials. Results Forty-four participants completed the study: 15 in the control group, 14 in the massage group, and 15 in the massage plus stretches group. Some improvement was seen in work-related discomfort by the QuickDASH scores and work module scores in the 2 intervention groups. The separation test showed separation in favor of the 2 interventions. Conclusion On the basis of the results of this pilot study, larger trials are warranted to evaluate the effect of massages with or without stretching on work-related discomfort in cardiac sonographers. Trial Registration NCT00975026 ClinicalTrials.gov PMID:20846441

  12. Peripheral hypoechoic spaces in consolidated lung: a specific diagnostic sonographic finding for necrotizing pneumonia in children.

    PubMed

    Chiu, Chih-Yung; Wong, Kin-Sun; Lai, Shen-Hao; Huang, Yu-Hsuan; Tsai, Ming-Han; Lin, Yu-Ching

    2008-01-01

    The aim of this study was to investigate the diagnostic usefulness and clinical values of the sonographic feature of peripheral hypoechoic spaces (PHES) in children with necrotizing pneumonia (NP). Between July 2002 and July 2004, 23 consecutive children with NP in whom we performed real-time chest ultrasound were enrolled into our study. Details of demographics, clinical characteristics, laboratory data, causative pathogens, complications and outcomes of these children were recorded and analyzed. PHES in ultrasonography (US) were defined as peripheral cavitations seen as hypoechoic areas in consolidated lung. The sonographic feature of PHES was correlated with the diagnosis of NP and was also used to correlate with the clinical characteristics, complications and outcomes in children with NP. Sensitivity, specificity, and positive predictive value of this sonographic finding for the diagnosis of NP were 35%, 100%, and 100%, respectively. Pneumothorax was seen more commonly in children who presented PHES in US, with a significant difference (p < 0.05). In conclusion, the sonographic feature of PHES appears to be more specific for detecting NP in childhood pneumonia. In children with pneumonia with PHES in consolidated lung, the diagnosis of NP can be suggested with confidence, and it is important to be aware of the life-threatening complication of pneumothorax to decrease morbidity.

  13. Sonographic features of invasive ductal breast carcinomas predictive of malignancy grade

    PubMed Central

    Gupta, Kanika; Kumaresan, Meenakshisundaram; Venkatesan, Bhuvaneswari; Chandra, Tushar; Patil, Aruna; Menon, Maya

    2018-01-01

    Context: Assessment of individual sonographic features provides vital clues about the biological behavior of breast masses and can assist in determining histological grade of malignancy and thereby prognosis. Aims: Assessment of individual sonographic features of biopsy proven invasive ductal breast carcinomas as predictors of malignancy grade. Settings and Design: A retrospective analysis of sonographic findings of 103 biopsy proven invasive ductal breast carcinomas. Materials and Methods: Tumor characteristics on gray-scale ultrasound and color flow were assessed using American College of Radiology (ACR) Breast Imaging Reporting and Data System (BI-RADS) Atlas Fifth Edition. The sonographic findings of masses were individually correlated with their histopathologic grades. Statistical Analysis Used: Chi square test, ordinal regression, and Goodman and Kruskal tau test. Results: Breast mass showing reversal/lack of diastolic flow has a high probability of belonging to histological high grade tumor (β 1.566, P 0.0001). The masses with abrupt interface boundary are more likely grade 3 (β 1.524, P 0.001) in comparison to masses with echogenic halos. The suspicious calcifications present in and outside the mass is a finding associated with histologically high grade tumors. The invasive ductal carcinomas (IDCs) with complex solid and cystic echotexture are more likely to be of high histological grade (β 1.146, P 0.04) as compared to masses with hypoechoic echotexture. Conclusions: Certain ultrasound features are associated with tumor grade on histopathology. If the radiologist is cognizant of these sonographic features, ultrasound can be a potent modality for predicting histopathological grade of IDCs of the breast, especially in settings where advanced tests such as receptor and molecular analyses are limited. PMID:29692540

  14. Hashimoto thyroiditis: Part 2, sonographic analysis of benign and malignant nodules in patients with diffuse Hashimoto thyroiditis.

    PubMed

    Anderson, Lauren; Middleton, William D; Teefey, Sharlene A; Reading, Carl C; Langer, Jill E; Desser, Terry; Szabunio, Margaret M; Mandel, Susan J; Hildebolt, Charles F; Cronan, John J

    2010-07-01

    The purpose of this article is to compare sonographic features of benign and malignant nodules in patients with diffuse Hashimoto thyroiditis. As part of an ongoing multiinstitutional study, patients who underwent ultrasound and fine-needle aspiration of one or more thyroid nodules were analyzed for a variety of predetermined sonographic features. Patients with a sonographic appearance consistent with diffuse Hashimoto thyroiditis and with coexisting nodules that could be confirmed to be benign or malignant by fine-needle aspiration or surgical pathologic analysis were included in the study. Among nodules within diffuse Hashimoto thyroiditis, 84% (69/82) were benign (35 nodular Hashimoto thyroiditis, 32 nodular hyperplasia, and two follicular adenoma), and 16% (13/82) were malignant (12 papillary carcinoma and one lymphoma). Malignant nodules were more likely to be solid and hypoechoic (62% vs 19%). All types of calcifications were more prevalent among malignant nodules, including microcalcifications (39% vs 0%), nonspecific tiny bright reflectors (39% vs 6%), macrocalcifications (15% vs 3%), and eggshell (15% vs 2%). Benign nodules were more likely to be hyperechoic (46% vs 9%), to have a halo (39% vs 15%), and to lack calcifications (88% vs 23%). Benign nodules more often had ill-defined margins (36% vs 8%). Sonographic features of benign and malignant nodules within diffuse Hashimoto thyroiditis are generally similar to the features typical of benign and malignant nodules in the general population. If calcifications of any type are added to the list of malignant sonographic features, the decision to biopsy a nodule in patients with diffuse Hashimoto thyroiditis can be based on recommendations that have been published previously.

  15. Combined value of Virtual Touch tissue quantification and conventional sonographic features for differentiating benign and malignant thyroid nodules smaller than 10 mm.

    PubMed

    Zhang, Huiping; Shi, Qiusheng; Gu, Jiying; Jiang, Luying; Bai, Min; Liu, Long; Wu, Ying; Du, Lianfang

    2014-02-01

    This study aimed to investigate the value of sonographic features including Virtual Touch tissue quantification (VTQ; Siemens Medical Solutions, Mountain View, CA) for differentiating benign and malignant thyroid nodules smaller than 10 mm. Seventy-one thyroid nodules smaller than 10 mm with pathologic diagnoses were included in this study. The conventional sonographic features and quantitative elasticity features (VTQ) were observed and compared between benign and malignant nodules. There were 39 benign and 32 malignant nodules according to histopathologic examination. When compared with benign nodules, malignant nodules were more frequently taller than wide, poorly defined, and markedly hypoechoic (P < .05). Color Doppler sonographic features were not significantly different between benign and malignant nodules. The VTQ value for malignant nodules (mean ± SD 3.260 ± 0.725 m/s) was significantly higher than that of benign ones (2.108 ± 0.455 m/s; P < .001). The cutoff point for the differential diagnosis was 2.910 m/s, with sensitivity, specificity, a positive predictive value, a negative predictive value, and diagnostic accuracy of 71.9%, 100%, 100%, 81.2%, and 87.3% respectively. Logistic regression analysis showed that a taller-than-wide shape, a poorly defined boundary, marked hypoechogenicity, and a VTQ value greater than 2.910 m/s were independent risk factors for malignancy, with odds ratios of 69.366, 41.864, 5.945, and 64.991. The combination of VTQ with a taller-than-wide shape had the highest sensitivity and specificity of 90.6% and 97.4%. The shape, margin, echogenicity, and VTQ value are useful sonographic criteria for differentiating benign and malignant thyroid nodules smaller than 10 mm. When VTQ was combined with B-mode sonographic features, the sensitivity was improved significantly.

  16. Relationship Between Third-Trimester Sonographic Estimate of Fetal Weight and Mode of Delivery.

    PubMed

    Yee, Lynn M; Grobman, William A

    2016-04-01

    Some have suggested, based on limited data, that knowledge of an estimated fetal weight from a sonogram in a low-risk population, particularly in the setting of a larger fetus, is associated with increased risk of cesarean delivery. We aimed to investigate, among women delivering neonates weighing greater than 3500 g, whether having had a sonographically estimated fetal weight in temporal proximity to delivery was associated with the risk of cesarean delivery. We conducted a retrospective cohort study of term nulliparous women delivering live-born, cephalic, singleton, nonanomalous fetuses with birth weights of greater than 3500 g. The study was powered to detect a 30% change in cesarean delivery frequency with the presence of a sonographic examination after 36 weeks' gestation. Of the 2099 women meeting inclusion criteria, 419 (20%) had a sonographic examination after 36 weeks' gestation. Women were similar with respect to demographic and obstetric characteristics regardless of whether they underwent sonography. There were no differences in rates of cesarean delivery regardless of whether women had or did not undergo sonography after 36 weeks (33.2% versus 29.4%, respectively; P = .13). There also were no differences in rates of chorioamnionitis, postpartum hemorrhage, episiotomy, third- or fourth-degree perineal laceration, or neonatal adverse outcomes based on sonographic status. Findings were similar in a multivariable analysis, as well as when the study population was restricted to those with birth weights of greater than 4000 and 4500 g. In this population of neonates weighing greater than 3500 g, the presence of a sonographic examination was not associated with the frequency of cesarean delivery. © 2016 by the American Institute of Ultrasound in Medicine.

  17. A novel approach to patient self-monitoring of sonographic examinations using a head-mounted display.

    PubMed

    Inoue, Masaharu; Kihara, Kazunori; Yoshida, Soichiro; Ito, Masaya; Takeshita, Hideki; Ishioka, Junichiro; Matsuoka, Yoh; Numao, Noboru; Saito, Kazutaka; Fujii, Yasuhisa

    2015-01-01

    Patients' use of a head-mounted display during their sonographic examinations could provide them with information about their diseases in real time and might help improve "patient-centered care." We conducted this prospective study to evaluate the feasibility of a modern head-mounted display for patient self-monitoring of sonographic examinations. In November and December 2013, 58 patients were enrolled. Patients wore a head-mounted display (HMZ-T2; Sony Corporation, Tokyo, Japan) during their sonographic examinations and watched their own images in real time. After the sonographic examinations, the patients completed a questionnaire, in which they evaluated the utility of the head-mounted display, their understanding of their diseases, their satisfaction with using the head-mounted display, and any adverse events. Until November 26, 2013, patients' names were requested on the questionnaire; after that date, the questionnaire was changed to be anonymous. Of the 58 patients, 56 (97%) elected to participate in this study. The head-mounted display was reported to have good image quality by 42 patients (75%) and good wearability by 39 (70%). Thirty-six patients (64%) reported they had deepened their understanding of their diseases. There were no major complications, and only 2 patients (4%) had mild eye fatigue. There was no significant association between questionnaire results and patient characteristics. None of the questionnaire results changed significantly after the questionnaire was made anonymous. The use of a modern head-mounted display by patients during sonographic examinations provided good image quality with acceptable wearability. It could deepen their understanding of their diseases and help develop patient-centered care. © 2015 by the American Institute of Ultrasound in Medicine.

  18. Fruit and Vegetable Production Unit for Plant Science Core Curriculum. Instructor's Guide. Volume 16, Number 3.

    ERIC Educational Resources Information Center

    Stewart, Bob R.; Mullinix, Mark K.

    This curriculum guide, part of a plant science core curriculum, consists of materials for use in teaching a unit on fruit and vegetable production. Provided in the first part of the guide are a list of objectives, a bibliography, and a competency profile. The remainder of the guide consists of 11 lessons dealing with the following topics: planning…

  19. Sidescan sonar as a tool for detection of demersal fish habitats

    USGS Publications Warehouse

    Able, Kenneth W.; Twichell, David C.; Grimes, Churchill B.; Jones, R. S.

    1987-01-01

    Sidescan sonar can be an effective tool for the determination of the habitat distribution of commercially important species.  This technique has the advantage of rapidly mapping large areas of the seafloor.  Sidescan images (sonographs) may also help to identify appropriate fishing gears for different types of seafloor or areas to be avoided with certain types of gears.  During the early stages of exploration, verification of sidescan sonar sonographs is critical to successful identification of important habitats.  Tilefishes (Lopholatilus and Caulolatilus) are especially good target species because the construct large burrows in the seafloor or live around boulders, both of which are easily detectable on sonographs.  In some special circumstances the estimates of tilefish burrow densities from sonographs can be used to estimate standing stock. In many localities the burrow and boulder habitats of tilefish are shared with other commercially important species such as American lobsters, Homarus americanus; cusk, Brosme brosme; and ocean pout, Macrozoarces americanus.

  20. Point-of-care sonographic detection of left endobronchial main stem intubation and obstruction versus endotracheal intubation.

    PubMed

    Blaivas, Michael; Tsung, James W

    2008-05-01

    Determining the correct position of endotracheal tubes in critically ill patients may be complicated by external factors such as noise, body habitus, and the need for ongoing resuscitation. Multiple detection techniques have been developed to determine the correct endotracheal tube position, recently including the use of sonography to evaluate lung expansion and diaphragmatic excursion. These techniques have also been applied to diagnosis of right endobronchial main stem intubation, which may be confused with a unilateral pneumothorax in some cases. We describe the sonographic findings in a case series of endobronchial main stem intubations and obstruction, highlighting the utility of this sonographic application. Previous literature and future applications are discussed. Sonographic detection of the sliding lung sign, the lung pulse, and diaphragmatic excursion can accurately detect main stem bronchial intubation as well as bronchial obstruction. Clinical use of lung sonography may decrease the need for chest radiography and may allow more rapid diagnosis of main stem intubation and bronchial obstruction.

  1. Sonographic physical diagnosis 101: teaching senior medical students basic ultrasound scanning skills using a compact ultrasound system.

    PubMed

    Angtuaco, Teresita L; Hopkins, Robert H; DuBose, Terry J; Bursac, Zoran; Angtuaco, Michael J; Ferris, Ernest J

    2007-06-01

    This project was designed to test the feasibility of introducing ultrasound to senior medical students as a primary diagnostic tool in the evaluation of patients. Specifically, its aim was to determine if it is possible for medical students untrained in sonography to gain basic competence in performing abdominal ultrasound with limited didactic and hands-on instructions. Registered sonographers provided the students with hands-on instructions on the use of a compact ultrasound system. They were likewise shown how to evaluate specific organs and perform measurements. The results of the student measurements and those obtained by the sonographers were compared. There was close correlation between the results obtained by sonographers and students on both normal and abnormal findings. This supports the concept that medical students can be taught basic ultrasound skills with limited didactic and hands-on instructions with the potential of using these skills in the patient clinics as an adjunct to routine physical diagnosis.

  2. Students' learning of clinical sonography: use of computer-assisted instruction and practical class.

    PubMed

    Wood, A K; Dadd, M J; Lublin, J R

    1996-08-01

    The application of information technology to teaching radiology will profoundly change the way learning is mediated to students. In this project, the integration of veterinary medical students' knowledge of sonography was promoted by a computer-assisted instruction program and a subsequent practical class. The computer-assisted instruction program emphasized the physical principles of clinical sonography and contained simulations and user-active experiments. In the practical class, the students used an actual sonographic machine for the first time and made images of a tissue-equivalent phantom. Students' responses to questionnaires were analyzed. On completing the overall project, 96% of the students said that they now understood sonographic concepts very or reasonably well, and 98% had become very or moderately interested in clinical sonography. The teaching and learning initiatives enhanced an integrated approach to learning, stimulated student interest and curiosity, improved understanding of sonographic principles, and contributed to an increased confidence and skill in using sonographic equipment.

  3. Disparity between Clinical and Ultrasound Examinations in Neonatal Hip Screening.

    PubMed

    Kyung, Bong Soo; Lee, Soon Hyuck; Jeong, Woong Kyo; Park, Si Young

    2016-06-01

    For early detection of developmental dysplasia of the hip (DDH), neonatal hip screening using clinical examination and/or ultrasound has been recommended. Although there have been many studies on the reliability of both screening techniques, there is still controversy in the screening strategies; clinical vs. selective or universal ultrasound screening. To determine the screening strategy, we assessed the agreement among the methods; clinical examination by an experienced pediatric orthopedic surgeon, sonographic morphology, and sonographic stability. From January 2004 to June 2009, a single experienced pediatric orthopedic surgeon performed clinical hip screenings for 2,686 infants in the neonatal unit and 43 infants who were referred due to impressions of hip dysplasia before 3 months of age. Among them, 156 clinically unstable or high-risk babies selectively received bilateral hip ultrasound examinations performed by the same surgeon using the modified Graf method. The results were analyzed statistically to detect any correlations between the clinical and sonographic findings. Although a single experienced orthopedic surgeon conducted all examinations, we detected only a limited relationship between the results of clinical and ultrasound examinations. Ninety-three percent of the clinically subluxatable hips were normal or immature based on static ultrasound examination, and 74% of dislocating hips and 67% of limited abduction hips presented with the morphology below Graf IIa. A total of 80% of clinically subluxatable, 42% of dislocating and 67% of limited abduction hips appeared stable or exhibited minor instability on dynamic ultrasound examination. About 7% of clinically normal hips were abnormal upon ultrasound examination; 5% showed major instability and 3% showed dysplasia above Graf IIc. Clinical stability had small coefficients between ultrasound examinations; 0.39 for sonographic stability and 0.37 for sonographic morphology. Between sonographic stability and morphology, although 71% of hips with major instability showed normal or immature morphology according to static ultrasound examination, the coefficient was as high as 0.64. Discrepancies between clinical and ultrasound examinations were present even if almost all of the exams were performed by a single experienced pediatric orthopedic surgeon. In relation to screening for DDH, it is recommended that both sonographic morphology and stability be checked in addition to clinical examination.

  4. Silica aerogel core waveguide.

    PubMed

    Grogan, M D W; Leon-Saval, S G; England, R; Birks, T A

    2010-10-11

    We have selectively filled the core of hollow photonic crystal fibre with silica aerogel. Light is guided in the aerogel core, with a measured attenuation of 0.2 dB/cm at 1540 nm comparable to that of bulk aerogel. The structure guides light by different mechanisms depending on the wavelength. At long wavelengths the effective index of the microstructured cladding is below the aerogel index of 1.045 and guidance is by total internal reflection. At short wavelengths, where the effective cladding index exceeds 1.045, a photonic bandgap can guide the light instead. There is a small region of crossover, where both index- and bandgap-guided modes were simultaneously observed.

  5. Arthroscopic-assisted core decompression of the humeral head.

    PubMed

    Dines, Joshua S; Strauss, Eric J; Fealy, Stephen; Craig, Edward V

    2007-01-01

    Humeral head osteonecrosis is a progressive disease that requires prompt diagnosis and treatment. Core decompression is a viable treatment option for early-stage cases. Most surgeons perform core decompression by arthroscopically visualizing the necrotic area of bone and using a cannulated drill to take a core. Several attempts are frequently needed to reach the proper location. In the hip multiple passes are associated with complications. We describe the use of an anterior cruciate ligament (ACL) tibial drill guide to precisely localize the area of necrotic bone. Diagnostic arthroscopy is performed to assess the areas of osteonecrosis. Core decompression is performed by use of an ACL tibial guide, brought in through the anterior or posterior portal to precisely localize the necrotic area in preparation for drilling. Under image intensification, Steinmann pins are advanced into the area of osteonecrosis. Once positioned, several 4-mm cores are made. We treated 3 patients with this technique, and all had immediate pain relief. The use of the ACL guide allows precise localization of the area of humeral head involvement and avoids multiple drillings into unaffected areas. Initial indications are that arthroscopic-assisted core decompression with an ACL guide is an effective alternative to previously used methods.

  6. BioCore Guide: A Tool for Interpreting the Core Concepts of Vision and Change for Biology Majors

    PubMed Central

    Freeman, Scott; Wenderoth, Mary Pat; Crowe, Alison J.

    2014-01-01

    Vision and Change in Undergraduate Biology Education outlined five core concepts intended to guide undergraduate biology education: 1) evolution; 2) structure and function; 3) information flow, exchange, and storage; 4) pathways and transformations of energy and matter; and 5) systems. We have taken these general recommendations and created a Vision and Change BioCore Guide—a set of general principles and specific statements that expand upon the core concepts, creating a framework that biology departments can use to align with the goals of Vision and Change. We used a grassroots approach to generate the BioCore Guide, beginning with faculty ideas as the basis for an iterative process that incorporated feedback from more than 240 biologists and biology educators at a diverse range of academic institutions throughout the United States. The final validation step in this process demonstrated strong national consensus, with more than 90% of respondents agreeing with the importance and scientific accuracy of the statements. It is our hope that the BioCore Guide will serve as an agent of change for biology departments as we move toward transforming undergraduate biology education. PMID:26086653

  7. A study to evaluate the efficacy of image-guided core biopsy in the diagnosis and management of lymphoma--results in 103 biopsies.

    PubMed

    Vandervelde, C; Kamani, T; Varghese, A; Ramesar, K; Grace, R; Howlett, D C

    2008-04-01

    The reason for this study was to evaluate the ability of image-guided core biopsy to replace surgical excision by providing sufficient diagnostic and treatment information. All consecutive image-guided core biopsies in patients with a final diagnosis of lymphoma over a 6-year period at our institution were collected retrospectively. Case notes and pathology reports were reviewed and the diagnostic techniques used were recorded. Pathology reports were graded according to their diagnostic completeness and their ability to provide treatment information. Out of a total of 328 instances of lymphoma, 103 image-guided core biopsies were performed in 96 patients. In 78% of these, the diagnostic information obtained from the biopsy provided a fully graded and subtyped diagnosis of lymphoma with sufficient information to initiate therapy. In the head and neck 67% of core biopsies were fully diagnostic for treatment purposes compared to 91% in the thorax, abdomen and pelvis. Image-guided core biopsy has a number of cost and safety advantages over surgical excision biopsy and in suitable cases it can obviate the need for surgery in cases of suspected lymphoma. This is especially relevant for elderly patients and those with poor performance status.

  8. Portable ultrasound in disaster triage: a focused review.

    PubMed

    Wydo, S M; Seamon, M J; Melanson, S W; Thomas, P; Bahner, D P; Stawicki, S P

    2016-04-01

    Ultrasound technology has become ubiquitous in modern medicine. Its applications span the assessment of life-threatening trauma or hemodynamic conditions, to elective procedures such as image-guided peripheral nerve blocks. Sonographers have utilized ultrasound techniques in the pre-hospital setting, emergency departments, operating rooms, intensive care units, outpatient clinics, as well as during mass casualty and disaster management. Currently available ultrasound devices are more affordable, portable, and feature user-friendly interfaces, making them well suited for use in the demanding situation of a mass casualty incident (MCI) or disaster triage. We have reviewed the existing literature regarding the application of sonology in MCI and disaster scenarios, focusing on the most promising and practical ultrasound-based paradigms applicable in these settings.

  9. Remotely Guided Breast Sonography for Long-Term Space Missions: A Case Report and Discussion.

    PubMed

    Silva-Martinez, Jackelynne P; Sorice Genaro, Andreia; Wen, Hui Annie; Glauber, Naama; Russomano, Thais

    2017-12-01

    Space radiation can cause different types of cancers in crewmembers, especially during long-term space missions. To date, a complete bilateral breast ultrasound has not been performed at the International Space Station (ISS). A breast screening imaging technique could be a useful tool for early identification of breast cancer in astronauts. We hypothesized that breast ultrasound performed by a crewmember while being remotely guided by a specialist from the ground could be an essential tool for medical diagnosis in space. This project aimed to test an ultrasound screening protocol for breast tissue using real-time remotely guided telemedicine techniques. One female volunteer, with no previous medical experience, performed a self-scanned bilateral breast ultrasound exam guided by a remote sonographer. Dynamic ultrasound images were collected using a 25 mm broadband linear array transducer. To simulate fluid shift on the volunteer during microgravity, the bed was tilted -6°. Recorded ultrasound images were analyzed by radiologists, comparing the findings with a gold standard. The experiment demonstrated that real-time remotely guided sonography exam is feasible and can yield meaningful clinical results. This case study showed that remotely guided breast ultrasound can be performed and might become an important tool for diagnosis of breast cancer in space missions. The results cannot be generalized based on one subject, and additional research is warranted in this area in addition to its validation on the ISS. This technique, however, has potential for use as part of preventive medicine procedures for long-term space missions at the ISS, and eventually for human settlements on the Moon and Mars.

  10. Agricultural Mechanics Unit for Plant Science Core Curriculum. Volume 15, Number 4. Instructor's Guide.

    ERIC Educational Resources Information Center

    Linhardt, Richard E.; Hunter, Bill

    This instructor's guide is intended for use in teaching the agricultural mechanics unit of a plant science core curriculum. Covered in the individual units of the guide are the following topics: arc welding (following safety procedures, controlling distortion, selecting and caring for electrodes, identifying the material to be welded, and welding…

  11. BioCore Guide: A Tool for Interpreting the Core Concepts of Vision and Change for Biology Majors

    ERIC Educational Resources Information Center

    Brownell, Sara E.; Freeman, Scott; Wenderoth, Mary Pat; Crowe, Alison J.

    2014-01-01

    "Vision and Change in Undergraduate Biology Education" outlined five core concepts intended to guide undergraduate biology education: 1) evolution; 2) structure and function; 3) information flow, exchange, and storage; 4) pathways and transformations of energy and matter; and 5) systems. We have taken these general recommendations and…

  12. Experimental observation of spontaneous depolarized guided acoustic-wave Brillouin scattering in side cores of a multicore fiber

    NASA Astrophysics Data System (ADS)

    Hayashi, Neisei; Mizuno, Yosuke; Nakamura, Kentaro; Set, Sze Yun; Yamashita, Shinji

    2018-06-01

    Spontaneous depolarized guided acoustic-wave Brillouin scattering (GAWBS) was experimentally observed in one of the side cores of an uncoated multicore fiber (MCF). The frequency bandwidth in the side core was up to ∼400 MHz, which is 0.5 times that in the central core. The GAWBS spectrum of the side core of the MCF included intrinsic peaks, which had different acoustic resonance frequencies from those of the central core. In addition, the spontaneous depolarized GAWBS in the central/side core was unaffected by that in the other core. These results will lead to the development of polarization/phase modulators using an MCF.

  13. Modern sedimentary environments on the Rhode Island inner shelf, off the eastern United States

    USGS Publications Warehouse

    Knebel, H.J.; Needell, S. W.; O'Hara, C. J.

    1982-01-01

    Analyses of side-scan sonar records along with previously published bathymetric, textural and subbottom data reveal the sedimentary environments on the inner Continental Shelf south of Narragansett Bay, Rhode Island. The bottom topography in this area is characterized by a broad central depression bordered by shallow, irregular sea floor on the north and east and by a discontinuous, curvilinear ridge on the south and west. Four distinct environments were identified: 1. (1) Pre-Mesozoic coastal rocks are exposed on the sea floor at isolated locations near the shore (waterdepths <32 m). These exposures have pronounced, irregular topographic relief and produce blotchy patterns on side-scan sonographs. 2. (2) Glacial moraine deposits form the discontinuous offshore ridge. These deposits have hummocky sea-floor relief, are covered by lag gravel and boudlers, and appear as predominantly black (strongly reflective) patterns on the side-scan records. 3. (3) Over most of the shallow, irregular bottom in the northeast, on the flanks of the morainal ridge, and atop bathymetric highs, the sea floor is characterized as a mosaic of light and dark patches and lineations. The dark (more reflective) zones are areas of coarse sands and megaripples (wavelengths = 0.8-1.2 m that either have no detectable relief or are slightly depressed relative to surrounding (light) areas of finer-grained sands. 4. (4) Smooth beds that produce nearly featureless patterns on the sonographs occupy the broad central bathymetric depression as well as smaller depressions north and east of Block Island. Within the broad depression, sonographs having practically no shading indicate a central zone of modern sandy silt, whereas records having moderate tonality define a peripheral belt of silty sand. The sedimentary environments that are outlined range from erosional or non-depositional (bedrock, glacial moraine) to depositional (featureless beds), and include areas that may reflect a combination of erosional and depositional processes (textural patchiness). The distribution and characteristics of the environments reveal the general post-glacial sedimentary history of this area and provide a guide to future utilization of the shelf surface. ?? 1982.

  14. Ultrasound-guided Interventions for Core and Hip Injuries in Athletes.

    PubMed

    McCarthy, Eoghan; Hegazi, Tarek M; Zoga, Adam C; Morrison, William B; Meyers, William C; Poor, Alex E; Nevalainen, Mika T; Roedl, Johannes B

    2016-09-01

    Trauma and the mechanical strain of high-energy activity predispose athletes to pelvic injuries. Magnetic resonance imaging remains the primary modality for diagnosing these conditions, but ultrasonography-guided interventions are important in the management of core muscle, hip, and other pelvic conditions. This article reviews ultrasonography-guided interventions for injuries at the core, including the pelvis and hips. It reviews common injuries, procedure optimization, medication preparation, clinical evidence behind injections, tenotomy, and platelet-rich plasma. These interventions are especially important in athletes, because ultrasonography-guided procedures are often undertaken early in the treatment process, paralleling conservative rehabilitation to facilitate a faster return to play. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Sonographic findings of early pregnancy in the rudimentary horn of a unicornuate uterus: A two case report.

    PubMed

    Dove, Christine K; Harvey, Sara M; Spalluto, Lucy B

    Congenital uterine anomalies have a profound impact on reproductive outcomes. The unicornuate uterus accounts for approximately 20% of all congenital uterine anomalies. Unicornuate uterine anomalies with non-communicating rudimentary horns are at risk of developing ectopic pregnancy in the rudimentary horn. Given increased risked of uterine rupture, rudimentary horn pregnancies pose significant maternal health risks. Understanding the sonographic appearance of early pregnancy within the rudimentary horn of the unicornuate uterine configuration is imperative for appropriate and timely clinical management. We present two cases of pregnancy in the rudimentary horn of a unicornuate uterus diagnosed sonographically in the first trimester. Published by Elsevier Inc.

  16. Flexible liquid core light guide with focusing and light shaping attachments

    DOEpatents

    Kross, B.J.; Majewski, S.; Zorn, C.J.; Majewski, L.A.

    1997-11-04

    A liquid light guide system for ultraviolet light is disclosed that has a light shaping arrangement for the emitted light, a stable liquid core and sheath and reliable and effective end closures. 12 figs.

  17. Turbofan gas turbine engine with variable fan outlet guide vanes

    NASA Technical Reports Server (NTRS)

    Wood, Peter John (Inventor); LaChapelle, Donald George (Inventor); Grant, Carl (Inventor); Zenon, Ruby Lasandra (Inventor); Mielke, Mark Joseph (Inventor)

    2010-01-01

    A turbofan gas turbine engine includes a forward fan section with a row of fan rotor blades, a core engine, and a fan bypass duct downstream of the forward fan section and radially outwardly of the core engine. The forward fan section has only a single stage of variable fan guide vanes which are variable fan outlet guide vanes downstream of the forward fan rotor blades. An exemplary embodiment of the engine includes an afterburner downstream of the fan bypass duct between the core engine and an exhaust nozzle. The variable fan outlet guide vanes are operable to pivot from a nominal OGV position at take-off to an open OGV position at a high flight Mach Number which may be in a range of between about 2.5-4+. Struts extend radially across a radially inwardly curved portion of a flowpath of the engine between the forward fan section and the core engine.

  18. Breaking the glass ceiling: hollow OmniGuide fibers

    NASA Astrophysics Data System (ADS)

    Johnson, Steven G.; Ibanescu, Mihai; Skorobogatiy, Maksim A.; Weisberg, Ori; Engeness, Torkel D.; Soljacic, Marin; Jacobs, Steven A.; Joannopoulos, John D.; Fink, Yoel

    2002-04-01

    We argue that OmniGuide fibers, which guide light within a hollow core by concentric multilayer films having the property of omnidirectional reflection, have the potential to lift several physical limitations of silica fibers. We show how the strong confinement in OmniGuide fibers greatly suppresses the properties of the cladding materials: even if highly lossy and nonlinear materials are employed, both the intrinsic losses and nonlinearities of silica fibers can be surpassed by orders of magnitude. This feat, impossible to duplicate in an index-guided fiber with existing materials, would open up new regimes for long-distance propagation and dense wavelength-division multiplexing (DWDM). The OmniGuide-fiber modes bear a strong analogy to those of hollow metallic waveguides; from this analogy, we are able to derive several general scaling laws with core radius. Moreover, there is strong loss discrimination between guided modes, depending upon their degree of confinement in the hollow core: this allows large, ostensibly multi-mode cores to be used, with the lowest-loss TE01 mode propagating in an effectively single-mode fashion. Finally, because this TE01 mode is a cylindrically symmetrical ('azimuthally' polarized) singlet state, it is immune to polarization-mode dispersion (PMD), unlike the doubly-degenerate linearly-polarized modes in silica fibers that are vulnerable to birefringence.

  19. Sonographic Spectrum of Tunica Albuginea Cyst

    PubMed Central

    Alvarez, Daniel M.; Bhatt, Shweta; Dogra, Vikram S.

    2011-01-01

    Tunica albuginea (TA) cyst is the most common extratesticular benign mass, which is usually palpable. Ultrasound examination is the imaging modality of choice to characterize palpable testicular lesions. This pictorial essay presents the spectrum of sonographic features of TA cysts in order to assist radiologists in making the correct diagnosis and avoid unnecessary surgeries. PMID:21915386

  20. Air and its Sonographic Appearance: Understanding the Artifacts.

    PubMed

    Buttar, Simran; Cooper, Denrick; Olivieri, Patrick; Barca, Michael; Drake, Aaran B; Ku, Melvin; Rose, Gabriel; Siadecki, Sebastian D; Saul, Turandot

    2017-08-01

    Although air has traditionally been considered a barrier to sonographic imaging, when encountered in unusual settings it can serve as an important indicator of various pathologic states as well. Clinician recognition and thorough understanding of the characteristic pattern of artifacts generated by air are critical for making a number of important diagnoses. We present five emergency department cases in which air was visualized in a pathologic location. Pneumothorax, pneumoperitoneum, necrotizing fasciitis, or Fournier's gangrene, and subcutaneous emphysema and pneumomediastinum, can be rapidly and easily identified on ultrasound by the presence of air artifacts. The relevant sonographic findings are described and discussed in this article. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Due to its inherent impedance mismatch with other human tissues, air has a characteristic appearance on ultrasound that includes irregular hyperechoic structures, "dirty shadowing," A-lines, and decreased visualization of deeper structures. Knowledge of the sonographic appearance of air artifacts can assist the physician in making a diagnosis, selecting appropriate additional imaging, and enlisting specialist consultation. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Differential involvement of forearm muscles in ALS does not relate to sonographic structural nerve alterations.

    PubMed

    Schreiber, Stefanie; Schreiber, Frank; Debska-Vielhaber, Grazyna; Garz, Cornelia; Hensiek, Nathalie; Machts, Judith; Abdulla, Susanne; Dengler, Reinhard; Petri, Susanne; Nestor, Peter J; Vielhaber, Stefan

    2018-07-01

    We aimed to assess whether differential peripheral nerve involvement parallels dissociated forearm muscle weakness in amyotrophic lateral sclerosis (ALS). The analysis comprised 41 ALS patients and 18 age-, sex-, height- and weight-matched healthy controls. Strength of finger-extension and -flexion was measured using the Medical Research Council (MRC) scale. Radial, median and ulnar nerve sonographic cross-sectional area (CSA) and echogenicity, expressed by the hypoechoic fraction (HF), were determined. In ALS, finger extensors were significantly weaker than finger flexors. Sonographic evaluation revealed peripheral nerve atrophy, affecting various nerve segments in ALS. HF was unaltered. This systematic study confirmed a long-observed physical examination finding in ALS - weakness in finger-extension out of proportion to finger-flexion. This phenomenon was not related to any particular sonographic pattern of upper limb peripheral nerve alteration. In ALS, dissociated forearm muscle weakness could aid in the disease's diagnosis. Nerve ultrasound did not provide additional information on the differential involvement of finger-extension and finger-flexion strength. Copyright © 2018 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  2. Predicting student performance in sonographic scanning using spatial ability as an ability determinent of skill acquisition

    NASA Astrophysics Data System (ADS)

    Clem, Douglas Wayne

    Spatial ability refers to an individual's capacity to visualize and mentally manipulate three dimensional objects. Since sonographers manually manipulate 2D and 3D sonographic images to generate multi-viewed, logical, sequential renderings of an anatomical structure, it can be assumed that spatial ability is central to the perception and interpretation of these medical images. Using Ackerman's theory of ability determinants of skilled performance as a conceptual framework, this study explored the relationship of spatial ability and learning sonographic scanning. Beginning first year sonography students from four different educational institutions were administered a spatial abilities test prior to their initial scanning lab coursework. The students' spatial test scores were compared with their scanning competency performance scores. A significant relationship between the students' spatial ability scores and their scanning performance scores was found. This result suggests that the use of spatial ability tests for admission to sonography programs may improve candidate selection, as well as assist programs in adjusting instruction and curriculum for students who demonstrate low spatial ability.

  3. Sonographic findings of hepatobiliary fascioliasis accompanied by extrahepatic expansion and ectopic lesions.

    PubMed

    Teke, Memik; Önder, Hakan; Çiçek, Mutalip; Hamidi, Cihad; Göya, Cemil; Çetinçakmak, Mehmet Güli; Hattapoğlu, Salih; Ülger, Burak Veli

    2014-12-01

    The aim of the study was to describe the sonographic findings of hepatobiliary fascioliasis with extrahepatic expansion and ectopic lesions. The study included 45 patients with fascioliasis. All diagnoses were confirmed via serologic enzyme-linked immunosorbent assays. Sonographic findings in the hepatobiliary system, extrahepatic expansion, and ectopic lesions were defined. The most common hepatic lesions were subcapsular localized, small, confluent, multiple hypoechoic nodules with poorly defined borders. We also detected ectopic lesion in 5 patients (11.1%) and live parasites in the gallbladder and bile duct in 11 (24.4%). The large spectrum of entities in the differential diagnosis of hepatobiliary fascioliasis may lead to misdiagnosis and incorrect treatment. However, the diagnosis can be made when the characteristic sonographic features are seen, such as heterogeneity of the liver with multiple poorly defined hypoechoic-isoechoic lesions and multiple echogenic nonshadowing particles in the gallbladder or common bile ducts. Nonetheless, the differential diagnosis of fascioliasis versus other hepatic lesions may still be difficult. In these situations, pathologic confirmation should be performed to exclude the possibility of malignancy. © 2013 by the American Institute of Ultrasound in Medicine.

  4. Point-of-care ultrasound education: the increasing role of simulation and multimedia resources.

    PubMed

    Lewiss, Resa E; Hoffmann, Beatrice; Beaulieu, Yanick; Phelan, Mary Beth

    2014-01-01

    This article reviews the current technology, literature, teaching models, and methods associated with simulation-based point-of-care ultrasound training. Patient simulation appears particularly well suited for learning point-of-care ultrasound, which is a required core competency for emergency medicine and other specialties. Work hour limitations have reduced the opportunities for clinical practice, and simulation enables practicing a skill multiple times before it may be used on patients. Ultrasound simulators can be categorized into 2 groups: low and high fidelity. Low-fidelity simulators are usually static simulators, meaning that they have nonchanging anatomic examples for sonographic practice. Advantages are that the model may be reused over time, and some simulators can be homemade. High-fidelity simulators are usually high-tech and frequently consist of many computer-generated cases of virtual sonographic anatomy that can be scanned with a mock probe. This type of equipment is produced commercially and is more expensive. High-fidelity simulators provide students with an active and safe learning environment and make a reproducible standardized assessment of many different ultrasound cases possible. The advantages and disadvantages of using low- versus high-fidelity simulators are reviewed. An additional concept used in simulation-based ultrasound training is blended learning. Blended learning may include face-to-face or online learning often in combination with a learning management system. Increasingly, with simulation and Web-based learning technologies, tools are now available to medical educators for the standardization of both ultrasound skills training and competency assessment.

  5. Ultrasound covers and sonographic gels are embryo-toxic and could be replaced by non-toxic polyethylene bags and paraffin oil.

    PubMed

    Van der Auwera, I; D'Hooghe, T M

    1998-08-01

    The objective of this study was to test the hypothesis that ultrasound covers and sonographic gels, used during vaginal ultrasound, are toxic for mouse embryonic development in vitro. A prospective randomized design was used on pronucleate ova of F1 hybrid CBA x C57Bl female mice. The mice were superovulated with pregnant mare's serum gonadotrophin and human chorionic gonadotrophin and mated with CBA x C57Bl males. The pronucleate ova were randomly divided between culture media with the addition of commercially available ultrasound covers and sonographic gels in different concentrations. As controls and potential alternatives, plastic polyethylene bags and paraffin oil were tested simultaneously. Embryo-toxicity was assessed by documenting cleavage capacity, blastocyst formation and embryo degeneration in vitro. Exposure of culture medium to the ultrasound covers and sonographic gels tested resulted in a severely reduced cleavage capacity, a high incidence of embryo degeneration and absent or impaired blastocyst formation. This toxic effect could be reduced by high dilutions in vitro. In contrast, plastic polyethylene bags and paraffin oil had no influence on in-vitro development of mouse ova. We conclude that commercially available ultrasound latex covers and sonographic gels are toxic for mouse embryos and can potentially influence embryonic development during infertility treatment. It is safer to perform vaginal ultrasonic measurements using non-toxic paraffin oil (as contact fluid) and plastic polyethylene bags (as ultrasonic cover).

  6. The sonographic features of malignant mediastinal lymph nodes and a proposal for an algorithmic approach for sampling during endobronchial ultrasound.

    PubMed

    Alici, Ibrahim Onur; Yılmaz Demirci, Nilgün; Yılmaz, Aydın; Karakaya, Jale; Özaydın, Esra

    2016-09-01

    There are several papers on the sonographic features of mediastinal lymph nodes affected by several diseases, but none gives the importance and clinical utility of the features. In order to find out which lymph node should be sampled in a particular nodal station during endobronchial ultrasound, we investigated the diagnostic performances of certain sonographic features and proposed an algorithmic approach. We retrospectively analyzed 1051 lymph nodes and randomly assigned them into a preliminary experimental and a secondary study group. The diagnostic performances of the sonographic features (gray scale, echogeneity, shape, size, margin, presence of necrosis, presence of calcification and absence of central hilar structure) were calculated, and an algorithm for lymph node sampling was obtained with decision tree analysis in the experimental group. Later, a modified algorithm was applied to the patients in the study group to give the accuracy. The demographic characteristics of the patients were not statistically significant between the primary and the secondary groups. All of the features were discriminative between malignant and benign diseases. The modified algorithm sensitivity, specificity, and positive and negative predictive values and diagnostic accuracy for detecting metastatic lymph nodes were 100%, 51.2%, 50.6%, 100% and 67.5%, respectively. In this retrospective analysis, the standardized sonographic classification system and the proposed algorithm performed well in choosing the node that should be sampled in a particular station during endobronchial ultrasound. © 2015 John Wiley & Sons Ltd.

  7. Power Doppler ultrasound of rheumatoid synovitis: quantification of vascular signal and analysis of interobserver variability.

    PubMed

    Kamishima, Tamotsu; Tanimura, Kazuhide; Henmi, Mihoko; Narita, Akihiro; Sakamoto, Fumihiko; Terae, Satoshi; Shirato, Hiroki

    2009-05-01

    The objective of this study was to assess interobserver uncertainties in power Doppler (PD) examination of the fingers of patients with rheumatoid arthritis (RA), by separating the source of the discrepancy into (1) acquisition of the images and (2) criteria for assessment of the images. Twenty patients who had been diagnosed with RA were enrolled in this study. Ultrasound examinations were performed by one inexperienced and two experienced sonographers. Interobserver variation was measured using a conventional semiquantitative image grading scale. Interobserver variation of the quantitative PD (QPD) index (the summation of the colored pixels in a region of interest) was also assessed. The agreement was higher between the two experienced sonographers (kappa value of 0.8) than between experienced and inexperienced sonographers (kappa value, 0.6-0.7) in the semiquantitative image grading scale. Results suggest that the difference in the assessment on the image grading scale was due more to the difference in the acquisition of the images than to variations in the grading criteria between sonographers. An excellent relationship was noted between the image grading scale and the QPD index for Doppler signal with a Spearman's coefficient of rank correlation of 0.83 (P < 0.0001). Interobserver discrepancies in the image grading and QPD index methods were due more to the difference in the acquisition of the image than to the grading criteria used. The QPD index seems to be as reliable as the image grading scale with reasonable interobserver agreement between experienced sonographers.

  8. Can Contrast-Enhanced Sonography Detect Bowel Wall Fibrosis in Mixed Inflammatory and Fibrotic Crohn Disease Lesions in an Animal Model?

    PubMed

    Dillman, Jonathan R; Rubin, Jonathan M; Johnson, Laura A; Moons, David S; Higgins, Peter D R

    2017-03-01

    To determine whether contrast-enhanced sonographic quantitative perfusion parameters can detect bowel wall fibrosis in the setting of mixed inflammatory and fibrotic lesions in a Crohn disease animal model. This study was approved by the institutional Committee on the Use and Care of Animals. Multiple (range, 1-5) 2,4,6-trinitrobenzenesulfonic acid-ethanol enemas were used to create intestinal inflammatory lesions with variable fibrosis in female Lewis rats. Low-mechanical index contrast-enhanced sonography was performed 3 days after the final enema using a 0.2-mL bolus of sulfur hexafluoride microbubbles injected through a tail vein. Contrast-enhanced sonographic data were analyzed with software that converts video data into echo-power (linearized) data. Colorectal lesions were scored for histopathologic inflammation and fibrosis; bowel wall collagen was quantified by Western blotting. The Spearman correlation was used to assess associations between contrast-enhanced sonographic quantitative parameters and bowel wall collagen; the Kruskal-Wallis test was used to compare continuous results between histopathologic groups. Thirty-one animals were included in our analysis. Animals were placed into 3 histopathologic cohorts: (1) severe bowel wall inflammation/minimal or no fibrosis (n = 11); (2) severe bowel wall inflammation/moderate fibrosis (n = 9); and (3) severe bowel wall inflammation/severe fibrosis (n = 11). Western blotting showed a significant difference in bowel wall collagen between histopathologic cohorts (P = .0001). There was no correlation between any contrast-enhanced sonographic quantitative parameter and bowel wall collagen (P > .05). There was no difference between histopathologic cohorts for any contrast-enhanced sonographic quantitative parameter (P > .05). Contrast-enhanced sonographic quantitative perfusion parameters failed to effectively detect bowel wall fibrosis in the setting of superimposed inflammation in a Crohn disease animal model. © 2017 by the American Institute of Ultrasound in Medicine.

  9. Intraindividual right-left comparison of sonographic features in polycystic ovary syndrome (PCOS) diagnosis.

    PubMed

    Köninger, Angela; Koch, Laura; Edimiris, Philippos; Nießen, Stefanie; Kasimir-Bauer, Sabine; Kimmig, Rainer; Strowitzki, Thomas; Schmidt, Börge

    2014-10-01

    Sonographic features of polycystic ovaries consist of elevated antral follicle count or ovarian volume of at least one ovary. The aim of this prospective cross-sectional study was to estimate intraindividual differences in sonographic measurements between the both ovaries of PCOS patients and controls and clinical consequences. Both ovaries of 85 PCOS patients and 48 controls were scanned transvaginally and agreement of sonographic measurements was analyzed using the Bland-Altman method. Concordance correlation coefficients (CCC) were computed. Mean differences between right and left ovaries were 0.24 (95% confidence interval [95% CI]: -0.32-0.80) follicles for AFC and 1.14 (95% CI: 0.34-1.92)ml for OV in the whole study population, 0.14 (95% CI: -0.68-0.96) follicles for AFC and 1.48 (95% CI: 0.39-2.58)ml for OV in PCOS patients, 0.42 (95% CI: -0.19-1.02) follicles for AFC and 0.53 (95% CI: -0.50-1.56)ml for OV in controls. Rather wide limits of agreement and low CCCs (<0.7 for all estimates) indicated poor agreement between the ovaries for both sonographic measurements. Width between lower and upper limits of agreement was higher for PCOS patients than for controls. 23.5% of the PCOS patients showed polycystic ovarian morphology (PCOM) only in one ovary, resulting in 9.4% potentially missed PCOS diagnosis according to the Rotterdam ESHRE/ASRM-Sponsored PCOS Consensus Workshop Group. Substantial differences in antral follicle count and ovarian volume between the right and left ovary were observed. In approximately 10% of the PCOS patients in our study only the examination of both ovaries has led to a reliable diagnosis of PCOS. In clinical practice it is recommended to scan both ovaries for a reliable diagnosis of abnormal sonographic findings in PCOM and PCOS diagnosis. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  10. The Prevalence of and Risk Factors Associated with Musculoskeletal Disorders among Sonographers in Central China: A Cross-Sectional Study

    PubMed Central

    Feng, Qingmin; Liu, Shenglin; Yang, Lei; Xie, Mingxing

    2016-01-01

    Objective Studies from industrialized countries show that musculoskeletal disorders (MSD) occur commonly in sonographers. However, little is known about sonographers in China, where the awareness of ergonomics and MSD, workload, and available equipment/facilities may differ. We aimed to investigate the prevalence of MSD and associated risk factors in sonographers in central China. Methods A cross-sectional survey was conducted with 381 sonographers from 14 randomly selected tertiary hospitals in Hubei province, central China. Musculoskeletal symptoms (using the Nordic Questionnaire) and risk factors (mostly derived from the Health Benefit Trust survey instrument and the Dutch Musculoskeletal Questionnaire) were recorded. Multivariate logistic regression was used to quantify associations between risk factors and MSD. Results The 12-month period prevalence of MSD was 98.3%, being highest in the neck (93.5%) and shoulder (92.2%), followed by the lower back (83.2%), wrist/hand, upper back, and elbow. Factors contributing to neck pain were psychological fatigue, shoulder abduction and trunk bend-and-twist posture. Height-adjustable tables and chairs were protective factors. Shoulder pain was associated with female sex, health status, mental stress, shoulder abduction, and trunk bend-and-twist posture. Height-adjustable chairs and the awareness of adjusting the workstation before scanning were protective factors. Elbow pain was associated with health status and height-adjustable tables. Wrist/hand pain was associated with female sex, bending the wrist, and working with obese patients. Upper back pain was associated with shoulder abduction, height-adjustable chairs, and device location. Lower back pain was associated with the number of scans performed per day, awkward postures, bending the trunk, twisting or bending the neck forward, and using a footrest. Conclusions This study suggests a high prevalence of MSD in sonographers in central China. Hence, it is necessary to improve the awareness of MSD by training, and the ergonomics of their current work environment by addressing physical workload, and psychological and equipment/facility-related factors. PMID:27695095

  11. Real-time virtual sonography, a coordinated sonography and MRI system that uses magnetic navigation, improves the sonographic identification of enhancing lesions on breast MRI.

    PubMed

    Nakano, Shogo; Yoshida, Miwa; Fujii, Kimihito; Yorozuya, Kyoko; Kousaka, Junko; Mouri, Yukako; Fukutomi, Takashi; Ohshima, Yukihiko; Kimura, Junko; Ishiguchi, Tsuneo

    2012-01-01

    This study verified that recently developed real-time virtual sonography (RVS) to coordinate a sonography image and the magnetic resonance imaging (MRI) multiplanar reconstruction (MPR) with magnetic navigation was useful. The purpose of this study was to evaluate the accuracy of RVS to sonographically identify enhancing lesions by breast MRI. Between December 2008 and May 2009, RVS was performed in 51 consecutive patients with 63 enhancing lesions. MRI was performed with the patients in the supine position using a 1.5-T imager with a body surface coil to achieve the same position as with sonography. To assess the accuracy of the RVS, the following three issues were analyzed: (i) The sonographic detection rate of enhancing lesions, (ii) the comparison of the tumor size measured by sonography and the MRI-MPR and (iii) the positioning errors as the distance from the actual sonographic position to the expected MRI position in 3-D. Among the 63 enhancing lesions, 42 (67%) lesions were identified by conventional B-mode, whereas the remaining 21 (33%) initial conventional B-mode occult lesions were identified by RVS alone. The sonographic size of the lesions detected by RVS alone was significantly smaller than that of lesions detected by conventional B-mode (p < 0.001). The mean tumor size provided by RVS was 12.3 mm for real-time sonography and 14.1 mm for MRI-MPR (r = 0.848, p < 0.001). The mean positioning errors for the transverse and sagittal planes and the depth from the skin were 7.7, 6.9 and 2.8 mm, respectively. The overall mean 3D positioning error was 12.0 mm. Our results suggest that RVS has good targeting accuracy to directly compare a sonographic image with MRI results without operator dependence. Copyright © 2012 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  12. Impact of audit of routine second-trimester cardiac images using a novel image-scoring method.

    PubMed

    Sairam, S; Awadh, A M A; Cook, K; Papageorghiou, A T; Carvalho, J S

    2009-05-01

    To assess the impact of using an objective scoring method to audit cardiac images obtained as part of the routine 21-23-week anomaly scan. A prospective audit and re-audit (6 months later) were conducted on cardiac images obtained by sonographers during the routine anomaly scan. A new image-scoring method was devised based on expected features in the four-chamber and outflow tract views. For each patient, scores were awarded for documentation and quality of individual views. These were called 'Documentation Scores' and 'View Scores' and were added to give a 'Patient Score' which represented the quality of screening provided by the sonographer for that particular patient (maximum score, 15). In order to assess the overall performance of sonographers, an 'Audit Score' was calculated for each by averaging his or her Patient Scores. In addition, to assess each sonographer's performance in relation to particular aspects of the various views, each was given their own 'Sonographer View Scores', derived from image documentation and details of four-chamber view (magnification, valve offset and septum) and left and right outflow tract views. All images were scored by two reviewers, jointly in the primary audit and independently in the re-audit. The scores from primary and re-audit were compared to assess the impact of feedback from the primary audit. Eight sonographers participated in the study. The median Audit Score increased significantly (P < 0.01), from 10.8 (range, 9.8-12.4) in the primary audit to 12.4 (range, 10.4-13.6) in the re-audit. Scores allocated by the two reviewers in the re-audit were not significantly different (P = 0.08). Objective scoring of fetal heart images is feasible and has a positive impact on the quality of cardiac images acquired at the time of the routine anomaly scan. This audit tool has the potential to be applied in every obstetric scanning unit and may improve the effectiveness of screening for congenital heart defects.

  13. Influence of different rotation angles in assessment of lung volumes by 3-dimensional sonography in comparison to magnetic resonance imaging in healthy fetuses.

    PubMed

    Kehl, Sven; Eckert, Sven; Sütterlin, Marc; Neff, K Wolfgang; Siemer, Jörn

    2011-06-01

    Three-dimensional (3D) sonographic volumetry is established in gynecology and obstetrics. Assessment of the fetal lung volume by magnetic resonance imaging (MRI) in congenital diaphragmatic hernias has become a routine examination. In vitro studies have shown a good correlation between 3D sonographic measurements and MRI. The aim of this study was to compare the lung volumes of healthy fetuses assessed by 3D sonography to MRI measurements and to investigate the impact of different rotation angles. A total of 126 fetuses between 20 and 40 weeks' gestation were measured by 3D sonography, and 27 of them were also assessed by MRI. The sonographic volumes were calculated by the rotational technique (virtual organ computer-aided analysis) with rotation angles of 6° and 30°. To evaluate the accuracy of 3D sonographic volumetry, percentage error and absolute percentage error values were calculated using MRI volumes as reference points. Formulas to calculate total, right, and left fetal lung volumes according to gestational age and biometric parameters were derived by stepwise regression analysis. Three-dimensional sonographic volumetry showed a high correlation compared to MRI (6° angle, R(2) = 0.971; 30° angle, R(2) = 0.917) with no systematic error for the 6° angle. Moreover, using the 6° rotation angle, the median absolute percentage error was significantly lower compared to the 30° angle (P < .001). The new formulas to calculate total lung volume in healthy fetuses only included gestational age and no biometric parameters (R(2) = 0.853). Three-dimensional sonographic volumetry of lung volumes in healthy fetuses showed a good correlation with MRI. We recommend using an angle of 6° because it assessed the lung volume more accurately. The specifically designed equations help estimate lung volumes in healthy fetuses.

  14. Determinants of Pediatric Echocardiography Laboratory Productivity: Analysis from the Second Survey of the American Society of Echocardiography Committee on Echocardiography Laboratory Productivity.

    PubMed

    Srivastava, Shubhika; Allada, Vivekanand; Younoszai, Adel; Lopez, Leo; Soriano, Brian D; Fleishman, Craig E; Van Hoever, Andrea M; Lai, Wyman W

    2016-10-01

    The American Society of Echocardiography Committee on Pediatric Echocardiography Laboratory Productivity aimed to study factors that could influence the clinical productivity of physicians and sonographers and assess longitudinal trends for the same. The first survey results indicated that productivity correlated with the total volume of echocardiograms. Survey questions were designed to assess productivity for (1) physician full-time equivalent (FTE) allocated to echocardiography reading (echocardiograms per physician FTE per day), (2) sonographer FTE (echocardiograms per sonographer FTE per year), and (3) machine utilization (echocardiograms per machine per year). Questions were also posed to assess work flow and workforce. For fiscal year 2013 or academic year 2012-2013, the mean number of total echocardiograms-including outreach, transthoracic, fetal, and transesophageal echocardiograms-per physician FTE per day was 14.3 ± 5.9, the mean number of echocardiograms per sonographer FTE per year was 1,056 ± 441, and the mean number of echocardiograms per machine per year was 778 ± 303. Both physician and sonographer productivity was higher at high-volume surgical centers and with echocardiography slots scheduled concordantly with clinic visits. Having an advanced imaging fellow and outpatient sedation correlated negatively with clinical laboratory productivity. Machine utilization was greater in laboratories with higher sonographer and physician productivity and lower for machines obtained before 2009. Measures of pediatric echocardiography laboratory staff productivity and machine utilization were shown to correlate positively with surgical volume, total echocardiography volumes, and concordant echocardiography scheduling; the same measures correlated negatively with having an advanced imaging fellow and outpatient sedation. There has been no significant change in staff productivity noted over two Committee on Pediatric Echocardiography Laboratory Productivity survey cycles, suggesting that hiring practices have matched laboratory volume increases. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  15. Endoscopic ultrasound-guided fine-needle aspiration with on-site cytopathology versus core biopsy: a comparison of both techniques performed at the same endoscopic session

    PubMed Central

    Lin, Michael; Hair, Clark D.; Green, Linda K.; Vela, Stacie A.; Patel, Kalpesh K.; Qureshi, Waqar A.; Shaib, Yasser H.

    2014-01-01

    Background: Endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) with bedside cytopathology is the gold standard for assessment of pancreatic, subepithelial, and other lesions in close proximity to the gastrointestinal tract, but it is time-consuming, has certain diagnostic limitations, and bedside cytopathology is not widely available. Aims: The goal of this study is to compare the diagnostic yield of EUS-guided FNA with on-site cytopathology and EUS-guided core biopsy. Methods: Twenty-six patients with gastrointestinal mass lesions requiring biopsy at a tertiary medical center were included in this retrospective analysis of a prospective cohort. Two core biopsies were taken using a 22 gauge needle followed by FNA guided by a bedside cytopathologist at the same endoscopic session. The diagnostic yield and test characteristics of EUS core biopsy and EUS FNA with bedside cytopathology were examined. Results: The mean number of passes was 3.2 for FNA, and the mean procedure time was 39.4 minutes. The final diagnosis was malignant in 92.3 %. Sensitivity and specificity were 83 % and 100 %, respectively, for FNA, and 91.7 % and 100 %, respectively, for core biopsy. Diagnostic accuracy was 92.3 % for FNA and 84.6 % for core biopsy. The two approaches were in agreement in 88.4 % with a kappa statistic of 0.66 (95 % confidence interval 0.33 – 0.99). Conclusions: An approach using two passes with a core biopsy needle is comparable to the current gold standard of FNA with bedside cytopathology. The performance of two core biopsies is time-efficient and could represent a good alternative to FNA with bedside cytopathology. PMID:26135096

  16. Transjugular intrahepatic portosystemic shunt creation using intravascular ultrasound guidance.

    PubMed

    Farsad, Khashayar; Fuss, Cristina; Kolbeck, Kenneth J; Barton, Robert E; Lakin, Paul C; Keller, Frederick S; Kaufman, John A

    2012-12-01

    To describe the use of intravascular ultrasound (US) guidance for creation of transjugular intrahepatic portosystemic shunts (TIPSs) in humans. The initial 25 cases of intravascular US-guided TIPS were retrospectively compared versus the last 75 conventional TIPS cases during the same time period at the same institution in terms of the number of needle passes required to establish portal vein (PV) access, fluoroscopy time, and needle pass-related complications. Intravascular US-guided TIPS creation was successful in all cases, and there was no statistically significant difference in number of needle passes, fluoroscopy time, or needle pass-related complications between TIPS techniques. Intravascular US-guided TIPS creation was successful in cases in which conventional TIPS creation had failed as a result of PV thrombosis or distorted anatomy. Intravascular US guidance for TIPS creation was additionally useful in a patient with Budd-Chiari syndrome and in a patient with intrahepatic tumors. Intravascular US is a safe and reproducible means of real-time image guidance for TIPS creation, equivalent in efficacy to conventional fluoroscopic guidance. Real-time sonographic guidance with intravascular US may prove advantageous for cases in which there is PV thrombus, distorted anatomy, Budd-Chiari syndrome, or hepatic tumors. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.

  17. EUS-guided, fine-needle aspiration biopsy using a new mechanical scanning puncture echoendoscope.

    PubMed

    Binmoeller, K F; Brand, B; Thul, R; Rathod, V; Soehendra, N

    1998-05-01

    A new mechanical sector scanning echoendoscope designed for EUS-guided, fine-needle aspiration biopsy (FNAB) was prospectively evaluated. The technical feasibility, safety, and histocytologic FNAB results are reported. Eighty-six patients underwent 106 FNAB procedures. The new echoendoscope has a 2.8 mm accessory channel and an elevator. Target sites: pancreas 58, lymph nodes 43, and miscellaneous lesions 5. Lesions were punctured with a 0.7 mm needle and submitted for cytologic and histologic examination. Definitive diagnosis was by surgery or clinical follow-up. The wide scanning field (250 degrees) enabled easy sonographic orientation for FNAB. Longitudinal needle visibility was "good" in 93% and 71% of transesophageal and transgastric procedures, respectively, but were compromised during most transduodenal procedures. Needle penetration of indurated pancreatic lesions failed in two patients, and in four additional patients pancreatic sampling succeeded only after a second attempt using an automated spring-loaded device. The mean number of passes was three. Ten percent of FNAB specimens were "inadequate"; excluding these, the diagnostic accuracy rate was 97%; sensitivity for malignancy was 88.5% and specificity was 100%. EUS-guided FNAB is feasible, safe, and accurate using the new mechanical puncture echoendoscope. Needle visibility needs to be improved, particularly for transduodenal FNAB.

  18. Prospective evaluation of magnetic resonance imaging guided in-bore prostate biopsy versus systematic transrectal ultrasound guided prostate biopsy in biopsy naïve men with elevated prostate specific antigen.

    PubMed

    Quentin, Michael; Blondin, Dirk; Arsov, Christian; Schimmöller, Lars; Hiester, Andreas; Godehardt, Erhard; Albers, Peter; Antoch, Gerald; Rabenalt, Robert

    2014-11-01

    Magnetic resonance imaging guided biopsy is increasingly performed to diagnose prostate cancer. However, there is a lack of well controlled, prospective trials to support this treatment method. We prospectively compared magnetic resonance imaging guided in-bore biopsy with standard systematic transrectal ultrasound guided biopsy in biopsy naïve men with increased prostate specific antigen. We performed a prospective study in 132 biopsy naïve men with increased prostate specific antigen (greater than 4 ng/ml). After 3 Tesla functional multiparametric magnetic resonance imaging patients were referred for magnetic resonance imaging guided in-bore biopsy of prostate lesions (maximum 3) followed by standard systematic transrectal ultrasound guided biopsy (12 cores). We analyzed the detection rates of prostate cancer and significant prostate cancer (greater than 5 mm total cancer length or any Gleason pattern greater than 3). A total of 128 patients with a mean ± SD age of 66.1 ± 8.1 years met all study requirements. Median prostate specific antigen was 6.7 ng/ml (IQR 5.1-9.0). Transrectal ultrasound and magnetic resonance imaging guided biopsies provided the same 53.1% detection rate, including 79.4% and 85.3%, respectively, for significant prostate cancer. Magnetic resonance imaging and transrectal ultrasound guided biopsies missed 7.8% and 9.4% of clinically significant prostate cancers, respectively. Magnetic resonance imaging biopsy required significantly fewer cores and revealed a higher percent of cancer involvement per biopsy core (each p <0.01). Combining the 2 methods provided a 60.9% detection rate with an 82.1% rate for significant prostate cancer. Magnetic resonance imaging guided in-bore and systematic transrectal ultrasound guided biopsies achieved equally high detection rates in biopsy naïve patients with increased prostate specific antigen. Magnetic resonance imaging guided in-bore biopsies required significantly fewer cores and revealed a significantly higher percent of cancer involvement per biopsy core. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  19. Endobronchial ultrasound-guided transbronchial needle aspiration for staging of lung cancer: a concise review.

    PubMed

    Aziz, Fahad

    2012-09-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) offers a minimally invasive alternative to mediastinoscopy with additional access to the hilar nodes, a better safety profile, and it removes the costs and hazards of theatre time and general anesthesia with comparable sensitivity, although the negative predictive value of mediastinoscopy (and sample size) is greater. EBUS- TBNA also obtains larger samples than conventional TBNA, has superior performance and theoretically is safer, allowing real-time sampling under direct vision. It can also have predictive value both in sonographic appearance of the nodes and histological characteristics. EBUS-TBNA is therefore indicated for NSCLC staging, diagnosis of lung cancer when there is no endobronchial lesion, and diagnosis of both benign (especially tuberculosis and sarcoidosis) and malignant mediastinal lesions. The procedure is different than for flexible bronchoscopy, takes longer, and requires more training. EBUS-TBNA is more expensive than conventional TBNA but can save costs by reducing the number of more costly mediastinoscopies. In the future, endobronchial ultrasound may have applications in airways disease and pulmonary vascular disease.

  20. Difficult preoperative diagnosis of a patient with sclerosing splenic hemangioma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edoute, Y.; Ben-Haim, S.A.; Ben-Arie, Y.

    1989-07-01

    We present a young asymptomatic woman with splenomegaly and a large isolated splenic mass demonstrated by ultrasonography, /sup 99m/Tc sulfur colloid, and gallium scintigraphy studies. Computerized tomography (CT) and three-phase 99mTc-labeled red blood cell imaging suggested a malignant lesion. Repeated sonographically guided fine needle aspiration (FNA) obtained only blood, suggesting the possible vascular nature of the tumor. Splenectomy established the diagnosis of splenic hemangioma (SH) with marked sclerotic changes. We conclude from this case that (1) the sclerotic and cystic changes in the SH and the abdominal lymphadenopathy could explain why the three-phase red blood cell and CT scanning, respectively,more » suggested that the lesion was malignant rather than benign; (2) guided FNA of a splenic mass suspected to be hemangioma may be an additional safe and useful diagnostic procedure. Multiple aspirations yielding blood alone suggest hemangioma and may prevent an unnecessary operation. To the best of our knowledge, this is the first reported case in the literature of FNA of splenic hemangioma.« less

  1. BioCore Guide: A Tool for Interpreting the Core Concepts of Vision and Change for Biology Majors.

    PubMed

    Brownell, Sara E; Freeman, Scott; Wenderoth, Mary Pat; Crowe, Alison J

    2014-01-01

    Vision and Change in Undergraduate Biology Education outlined five core concepts intended to guide undergraduate biology education: 1) evolution; 2) structure and function; 3) information flow, exchange, and storage; 4) pathways and transformations of energy and matter; and 5) systems. We have taken these general recommendations and created a Vision and Change BioCore Guide-a set of general principles and specific statements that expand upon the core concepts, creating a framework that biology departments can use to align with the goals of Vision and Change. We used a grassroots approach to generate the BioCore Guide, beginning with faculty ideas as the basis for an iterative process that incorporated feedback from more than 240 biologists and biology educators at a diverse range of academic institutions throughout the United States. The final validation step in this process demonstrated strong national consensus, with more than 90% of respondents agreeing with the importance and scientific accuracy of the statements. It is our hope that the BioCore Guide will serve as an agent of change for biology departments as we move toward transforming undergraduate biology education. © 2014 S. E. Brownell et al. CBE—Life Sciences Education © 2014 The American Society for Cell Biology. This article is distributed by The American Society for Cell Biology under license from the author(s). It is available to the public under an Attribution–Noncommercial–Share Alike 3.0 Unported Creative Commons License (http://creativecommons.org/licenses/by-nc-sa/3.0).

  2. The Value of Homemade Phantoms for Training Veterinary Students in the Ultrasonographic Detection of Radiolucent Foreign Bodies

    ERIC Educational Resources Information Center

    Mariano Beraldo, Carolina; Rondon Lopes, Érika; Hage, Raduan; Hage, Maria Cristina F. N. S.

    2017-01-01

    Ingested or penetrating foreign bodies are common in veterinary medicine. When they are radiolucent, these objects become a diagnostic challenge, but they can be investigated sonographically. However, successful object identification depends on the skill of the sonographer. Considering that these cases appear randomly during hospital routines, it…

  3. [Spontaneous splenic rupture as a complication of infectious mononucleosis].

    PubMed

    Barałkiewicz, G; Mijal, J; Karoń, J; Rybski, Z; Juszczyk, J

    1996-01-01

    Spontaneous splenic rupture as a complication of infectious mononucleosis in 17-years old man was described. Clinical manifestations of infectious mononucleosis were typical without any sign of the splenic rupture. At the end of third week of the disease sonographic investigation revealed subcapsular hematoma of the spleen without overt rupture. The patient was observed. Five days later in the next sonographic investigation the second hematoma of the spleen appeared. Patient was treated underwent splenectomy and he remain alive and well. Authors suggest that in cases with subcapsular hematoma of the spleen splenectomy remains the treatment of choice. Mononucleosis patients with significant enlarged spleen should be observed very carefully. Authors propose control sonographic investigation in 3rd or 4th week of the disease in those cases.

  4. Dynamic Sonographic Visualization of an Occult Posterior Lateral Meniscocapsular Separation: A Case Report.

    PubMed

    Schroeder, Allison; Musahl, Volker; Urbanek, Christopher; Onishi, Kentaro

    2018-04-05

    Meniscocapsular separation describes detachment of the meniscus from the knee joint capsule. Diagnosis is challenging with conventional examination and imaging methods. We report a case of an 18-year-old female softball catcher with unrevealing magnetic resonance imaging despite continued left knee locking and discomfort with deep squatting. Meniscocapsular separation was revealed only on dynamic sonographic exam, where knee flexion revealed a 3.1-mm gap that developed between the capsule and peripheral meniscus. Arthroscopy confirmed the sonographic findings, and repair resulted in complete resolution of symptoms. This case highlights the utility of dynamic diagnostic sonography in a rare case of posterior lateral meniscocapsular separation. Copyright © 2018 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  5. Particle levitation and guidance in hollow-core photonic crystal fiber.

    PubMed

    Benabid, Fetah; Knight, J; Russell, P

    2002-10-21

    We report the guidance of dry micron-sized dielectric particles in hollow core photonic crystal fiber. The particles were levitated in air and then coupled to the air-core of the fiber using an Argon ion laser beam operating at a wavelength of 514 nm. The diameter of the hollow core of the fiber is 20 m . A laser power of 80 mW was sufficient to levitate a 5 m diameter polystyrene sphere and guide it through a ~150 mm long hollow-core crystal photonic fiber. The speed of the guided particle was measured to be around 1 cm/s.

  6. Sonoanatomy relevant for ultrasound-guided central neuraxial blocks via the paramedian approach in the lumbar region

    PubMed Central

    Karmakar, M K; Li, X; Kwok, W H; Ho, A M-H; Ngan Kee, W D

    2012-01-01

    Objectives The use of ultrasound to guide peripheral nerve blocks is now a well-established technique in regional anaesthesia. However, despite reports of ultrasound guided epidural access via the paramedian approach, there are limited data on the use of ultrasound for central neuraxial blocks, which may be due to a poor understanding of spinal sonoanatomy. The aim of this study was to define the sonoanatomy of the lumbar spine relevant for central neuraxial blocks via the paramedian approach. Methods The sonoanatomy of the lumbar spine relevant for central neuraxial blocks via the paramedian approach was defined using a “water-based spine phantom”, young volunteers and anatomical slices rendered from the Visible Human Project data set. Results The water-based spine phantom was a simple model to study the sonoanatomy of the osseous elements of the lumbar spine. Each osseous element of the lumbar spine, in the spine phantom, produced a “signature pattern” on the paramedian sagittal scans, which was comparable to its sonographic appearance in vivo. In the volunteers, despite the narrow acoustic window, the ultrasound visibility of the neuraxial structures at the L3/L4 and L4/L5 lumbar intervertebral spaces was good, and we were able to delineate the sonoanatomy relevant for ultrasound-guided central neuraxial blocks via the paramedian approach. Conclusion Using a simple water-based spine phantom, volunteer scans and anatomical slices from the Visible Human Project (cadaver) we have described the sonoanatomy relevant for ultrasound-guided central neuraxial blocks via the paramedian approach in the lumbar region. PMID:22010025

  7. Patient-specific core decompression surgery for early-stage ischemic necrosis of the femoral head

    PubMed Central

    Wang, Wei; Hu, Wei; Yang, Pei; Dang, Xiao Qian; Li, Xiao Hui; Wang, Kun Zheng

    2017-01-01

    Introduction Core decompression is an efficient treatment for early stage ischemic necrosis of the femoral head. In conventional procedures, the pre-operative X-ray only shows one plane of the ischemic area, which often results in inaccurate drilling. This paper introduces a new method that uses computer-assisted technology and rapid prototyping to enhance drilling accuracy during core decompression surgeries and presents a validation study of cadaveric tests. Methods Twelve cadaveric human femurs were used to simulate early-stage ischemic necrosis. The core decompression target at the anterolateral femoral head was simulated using an embedded glass ball (target). Three positioning Kirschner wires were drilled into the top and bottom of the large rotor. The specimen was then subjected to computed tomography (CT). A CT image of the specimen was imported into the Mimics software to construct a three-dimensional model including the target. The best core decompression channel was then designed using the 3D model. A navigational template for the specimen was designed using the Pro/E software and manufactured by rapid prototyping technology to guide the drilling channel. The specimen-specific navigation template was installed on the specimen using positioning Kirschner wires. Drilling was performed using a guide needle through the guiding hole on the templates. The distance between the end point of the guide needle and the target was measured to validate the patient-specific surgical accuracy. Results The average distance between the tip of the guide needle drilled through the guiding template and the target was 1.92±0.071 mm. Conclusions Core decompression using a computer-rapid prototyping template is a reliable and accurate technique that could provide a new method of precision decompression for early-stage ischemic necrosis. PMID:28464029

  8. Patient-specific core decompression surgery for early-stage ischemic necrosis of the femoral head.

    PubMed

    Wang, Wei; Hu, Wei; Yang, Pei; Dang, Xiao Qian; Li, Xiao Hui; Wang, Kun Zheng

    2017-01-01

    Core decompression is an efficient treatment for early stage ischemic necrosis of the femoral head. In conventional procedures, the pre-operative X-ray only shows one plane of the ischemic area, which often results in inaccurate drilling. This paper introduces a new method that uses computer-assisted technology and rapid prototyping to enhance drilling accuracy during core decompression surgeries and presents a validation study of cadaveric tests. Twelve cadaveric human femurs were used to simulate early-stage ischemic necrosis. The core decompression target at the anterolateral femoral head was simulated using an embedded glass ball (target). Three positioning Kirschner wires were drilled into the top and bottom of the large rotor. The specimen was then subjected to computed tomography (CT). A CT image of the specimen was imported into the Mimics software to construct a three-dimensional model including the target. The best core decompression channel was then designed using the 3D model. A navigational template for the specimen was designed using the Pro/E software and manufactured by rapid prototyping technology to guide the drilling channel. The specimen-specific navigation template was installed on the specimen using positioning Kirschner wires. Drilling was performed using a guide needle through the guiding hole on the templates. The distance between the end point of the guide needle and the target was measured to validate the patient-specific surgical accuracy. The average distance between the tip of the guide needle drilled through the guiding template and the target was 1.92±0.071 mm. Core decompression using a computer-rapid prototyping template is a reliable and accurate technique that could provide a new method of precision decompression for early-stage ischemic necrosis.

  9. Sonography of cat scratch disease.

    PubMed

    Melville, David M; Jacobson, Jon A; Downie, Brian; Biermann, J Sybil; Kim, Sung Moon; Yablon, Corrie M

    2015-03-01

    To characterize the sonographic features of cat scratch disease and to identify features that allow differentiation from other causes of medial epitrochlear masses. After Institutional Review Board approval was obtained, patients who underwent sonography for a medial epitrochlear mass or lymph node were identified via the radiology information system. Patients were divided into 2 groups: cat scratch disease and non-cat scratch disease, based on pathologic results and clinical information. Sonograms were retrospectively reviewed and characterized with respect to dimension, shape (round, oval, or lobular), symmetry, location (subcutaneous or intramuscular), multiplicity, echogenicity (anechoic, hypoechoic, isoechoic, hyperechoic, or mixed), hyperechoic hilum (present or absent), adjacent anechoic or hypoechoic area, hyperemia (present or absent), pattern of hyperemia if present (central, peripheral, or mixed), increased posterior through-transmission (present or absent), and shadowing (present or absent). Sonographic findings were compared between the patients with and without cat scratch disease. The final patient group consisted of 5 cases of cat scratch disease and 16 cases of other causes of medial epitrochlear masses. The 2 sonographic findings that were significantly different between the cat scratch disease and non-cat scratch disease cases included mass asymmetry (P = .0062) and the presence of a hyperechoic hilum (P = .0075). The other sonographic findings showed no significant differences between the groups. The sonographic finding of an epitrochlear mass due to cat scratch disease most commonly is that of a hypoechoic lobular or oval mass with central hyperemia and a possible adjacent fluid collection; however, the presence of asymmetry and a hyperechoic hilum differentiate cat scratch disease from other etiologies. © 2015 by the American Institute of Ultrasound in Medicine.

  10. Sonographic appearance of thyroid cancer in patients with Hashimoto thyroiditis.

    PubMed

    Durfee, Sara M; Benson, Carol B; Arthaud, Dylan M; Alexander, Erik K; Frates, Mary C

    2015-04-01

    To determine whether the sonographic appearance of thyroid cancer differs in patients with and without Hashimoto thyroiditis. Patients with histologically proven thyroid cancer who had thyroid peroxidase (TPO) antibodies measured and sonography performed preoperatively were included. We evaluated each nodule for size, echogenicity, composition, margins, halo, and vascularity and evaluated the background heterogeneity of the gland. There were 162 thyroid cancers in 145 patients. Forty-two patients (29.0%) had Hashimoto thyroiditis with positive TPO antibodies, and 103 patients (71.0%) had negative TPO antibodies. The background echogenicity was more often heterogeneous in TPO antibody-positive patients compared to those who had negative TPO antibodies (57.1% versus 26.2%; P= .0005). Comparing cancers in TPO antibody-positive to TPO antibody-negative patients, there was no significant difference in the size, echogenicity, composition, margins, halo presence, calcification presence and type, or vascularity of the cancerous nodule (P > .05). Among TPO antibody-positive patients, comparing thyroid cancerous nodules in patients with heterogeneous glands to those with homogeneous glands, there was no significant difference in any sonographic characteristic except the margin of the nodule, which was more often irregular or poorly defined in heterogeneous glands and more often smooth in homogeneous glands (P< .05). Sonographic features of thyroid cancer are similar in patients with and without Hashimoto thyroiditis. Among patients with Hashimoto thyroiditis and thyroid cancer, the sonographic appearance of the cancerous nodule is similar, except that cancerous nodule margins are more likely to be irregular or poorly defined when the gland is heterogeneous. © 2015 by the American Institute of Ultrasound in Medicine.

  11. Prediction of polycystic ovarian syndrome based on ultrasound findings and clinical parameters.

    PubMed

    Moschos, Elysia; Twickler, Diane M

    2015-03-01

    To determine the accuracy of sonographic-diagnosed polycystic ovaries and clinical parameters in predicting polycystic ovarian syndrome. Medical records and ultrasounds of 151 women with sonographically diagnosed polycystic ovaries were reviewed. Sonographic criteria for polycystic ovaries were based on 2003 Rotterdam European Society of Human Reproduction and Embryology/American Society for Reproductive Medicine guidelines: at least one ovary with 12 or more follicles measuring 2-9 mm and/or increased ovarian volume >10 cm(3) . Clinical variables of age, gravidity, ethnicity, body mass index, and sonographic indication were collected. One hundred thirty-five patients had final outcomes (presence/absence of polycystic ovarian syndrome). Polycystic ovarian syndrome was diagnosed if a patient had at least one other of the following two criteria: oligo/chronic anovulation and/or clinical/biochemical hyperandrogenism. A logistic regression model was constructed using stepwise selection to identify variables significantly associated with polycystic ovarian syndrome (p < .05). The validity of the model was assessed using receiver operating characteristics and Hosmer-Lemeshow χ(2) analyses. One hundred twenty-eight patients met official sonographic criteria for polycystic ovaries and 115 (89.8%) had polycystic ovarian syndrome (p = .009). Lower gravidity, abnormal bleeding, and body mass index >33 were significant in predicting polycystic ovarian syndrome (receiver operating characteristics curve, c = 0.86). Pain decreased the likelihood of polycystic ovarian syndrome. Polycystic ovaries on ultrasound were sensitive in predicting polycystic ovarian syndrome. Ultrasound, combined with clinical parameters, can be used to generate a predictive index for polycystic ovarian syndrome. © 2014 Wiley Periodicals, Inc.

  12. Salivary gland mucosa-associated lymphoid tissue lymphoma in 2 patients with Sjögren's syndrome: clinical and sonographic features with pathological correlation.

    PubMed

    Lewis, Khari; Vandervelde, Clive; Grace, Richard; Ramesar, Keith; Williams, Michael; Howlett, David C

    2007-02-01

    We report 2 cases of mucosa-associated lymphoid tissue lymphoma of the salivary glands, complicating Sjögren's syndrome. The sonographic and histological features are described in depth. The use of sonography as a diagnostic aid in such patients is discussed. (c) 2006 Wiley Periodicals, Inc.

  13. Ultrasonographic findings in hereditary neuropathy with liability to pressure palsies.

    PubMed

    Bayrak, Ayse O; Bayrak, Ilkay Koray; Battaloglu, Esra; Ozes, Burcak; Yildiz, Onur; Onar, Musa Kazim

    2015-02-01

    The aims of this study were to evaluate the sonographic findings of patients with hereditary neuropathy with liability to pressure palsies (HNPP) and to examine the correlation between sonographic and electrophysiological findings. Nine patients whose electrophysiological findings indicated HNPP and whose diagnosis was confirmed by genetic analysis were enrolled in the study. The median, ulnar, peroneal, and tibial nerves were evaluated by ultrasonography. We ultrasonographically evaluated 18 median, ulnar, peroneal, and tibial nerves. Nerve enlargement was identified in the median, ulnar, and peroneal nerves at the typical sites of compression. None of the patients had nerve enlargement at a site of noncompression. None of the tibial nerves had increased cross-sectional area (CSA) values. There were no significant differences in median, ulnar, and peroneal nerve distal motor latencies (DMLs) between the patients with an increased CSA and those with a normal CSA. In most cases, there was no correlation between electrophysiological abnormalities and clinical or sonographic findings. Although multiple nerve enlargements at typical entrapment sites on sonographic evaluation can suggest HNPP, ultrasonography cannot be used as a diagnostic tool for HNPP. Ultrasonography may contribute to the differential diagnosis of HNPP and other demyelinating polyneuropathies or compression neuropathies; however, further studies are required.

  14. Transducer hygiene: comparison of procedures for decontamination of ultrasound transducers and their use in clinical practice.

    PubMed

    Häggström, Mikael; Spira, Jack; Edelstam, Greta

    2015-02-01

    To determine whether current hygiene practices are appropriate during sonographic examinations. Five major hospitals in Sweden were investigated with a survey. At each hospital, the departments corresponding to the main types of sonographic examination were chosen. Personnel who were responsible for or acquainted with the local hygiene procedures completed a standardardized questionnaire. The surveys were completed by 25 departments, where the total number of sonographic examinations was approximately 20,000 per month. For transvaginal and transrectal sonographic examinations, the most common method for decontamination of the transducer was barrier protection during the procedure followed by cleansing with alcohol. Latex was the predominant cover material, but one department used polyethylene gloves, and another department used nitrile gloves. Both of these involved transvaginal ultrasonography. In transcutaneous examinations, all hospitals were using alcohol and paper or cloth for decontamination at a minimum. Transesophageal examinations were carried out without barrier protection, and decontamination was performed with an alkylating substance. The hygiene practices appear to be appropriate at most hospitals, but there is a prevalence of transducer cover materials of unacceptable permeability, as well as use of gloves on transducers despite insufficient evidence of safety. © 2015 Wiley Periodicals, Inc.

  15. Ultrasound criteria and guided fine-needle aspiration diagnostic yields in small animal peritoneal, mesenteric and omental disease.

    PubMed

    Feeney, Daniel A; Ober, Christopher P; Snyder, Laura A; Hill, Sara A; Jessen, Carl R

    2013-01-01

    Peritoneal, mesenteric, and omental diseases are important causes of morbidity and mortality in humans and animals, although information in the veterinary literature is limited. The purposes of this retrospective study were to determine whether objectively applied ultrasound interpretive criteria are statistically useful in differentiating among cytologically defined normal, inflammatory, and neoplastic peritoneal conditions in dogs and cats. A second goal was to determine the cytologically interpretable yield on ultrasound-guided, fine-needle sampling of peritoneal, mesenteric, or omental structures. Sonographic criteria agreed upon by the authors were retrospectively and independently applied by two radiologists to the available ultrasound images without knowledge of the cytologic diagnosis and statistically compared to the ultrasound-guided, fine-needle aspiration cytologic interpretations. A total of 72 dogs and 49 cats with abdominal peritoneal, mesenteric, or omental (peritoneal) surface or effusive disease and 17 dogs and 3 cats with no cytologic evidence of inflammation or neoplasia were included. The optimized, ultrasound criteria-based statistical model created independently for each radiologist yielded an equation-based diagnostic category placement accuracy of 63.2-69.9% across the two involved radiologists. Regional organ-associated masses or nodules as well as aggregated bowel and peritoneal thickening were more associated with peritoneal neoplasia whereas localized, severely complex fluid collections were more associated with inflammatory peritoneal disease. The cytologically interpretable yield for ultrasound-guided fine-needle sampling was 72.3% with no difference between species, making this a worthwhile clinical procedure. © 2013 Veterinary Radiology & Ultrasound.

  16. Ultrasound-Guided Core-Needle Versus Vacuum-Assisted Breast Biopsy: A Cost Analysis Based on the American Society of Breast Surgeons' Mastery of Breast Surgery Registry.

    PubMed

    Grady, Ian; Vasquez, Tony; Tawfik, Sara; Grady, Sean

    2017-03-01

    To evaluate the cost-efficacy of vacuum-assisted ultrasound-guided breast biopsy instruments compared to ultrasound-guided 14-gauge spring-loaded core-needle biopsy. The American Society of Breast Surgeons' Mastery of Breast Surgery Registry was reviewed. Biopsy findings, any rebiopsy, and the instrument used were abstracted for 31,451 ultrasound-guided biopsy procedures performed between 2001 and July 2014. Rates of cancer diagnosis and rebiopsy were calculated for each instrument. A linear mathematical model was developed to calculate total cost per cancer diagnosis, including procedural costs and the costs of any additional surgical rebiopsy procedures. Mean cost per cancer diagnosis with confidence limits was then determined for 14-gauge spring-loaded core-needle biopsy and 14 different vacuum-assisted instruments. For 14-gauge spring-loaded core-needle biopsy, mean cost per cancer diagnosis was $4346 (4327-$4366). For the vacuum-assisted instruments, mean cost per cancer diagnosis ranged from a low of $3742 ($3732-$3752) to a high of $4779 ($4750-$4809). Vacuum-assisted instruments overall were more cost-effective than core with a mean cost per cancer diagnosis of $4052 ($4038-$4067) (p < 0.05). Tethered vacuum-assisted instruments performed best with a mean cost per cancer diagnosis of $3978 ($3964-$3991) (p < 0.05). Nontethered devices had a mean cost per cancer diagnosis of $4369 ($4350-$4388), a result no better than core (p < 0.05). Ultrasound-guided vacuum-assisted breast biopsy had a lower mean cost per cancer diagnosis than 14-gauge spring-loaded core-needle biopsy. This advantage was only seen in tethered vacuum-assisted instruments. Within device families, larger instruments tended to outperform smaller instruments.

  17. Combined use of serum HCG and sonography in the diagnosis of ectopic pregnancy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kadar, N.; Taylor, K.J.W.; Rosenfield, A.T.

    1983-09-01

    During an 18 month period, 320 patients were referred with clinical suspicion of an ectopic pregnancy. This study is based on 19 patients with ectopic pregnancy who had both a sonographic examination of the pelvis and determination of serum beta human chorionic gonadotropin (HCG) before surgery. Emphasis is focused on the spectrum of sonographic appearances that may occur in ectopic gestation. These are illustrated, and the sonographic criteria that have been used both for a positive diagnosis and for the exclusion of ectopic pregnancy in the past are analyzed. It is suggested that the accuracy of sonography can be increasedmore » by determining the serum HCG level on the day of the scan and by interpreting the findings with reference to the discriminatory HCG zone.« less

  18. Sonographic findings in horses with mediastinal lymphosarcoma: 13 cases (1985-1992).

    PubMed

    Garber, J L; Reef, V B; Reimer, J M

    1994-11-15

    Sonographic findings correlated with necropsy findings in 8 of 9 horses in which the cranial portion of the mediastinum was evaluated by use of both methods. Cranial mediastinal masses were imaged as multilobular and homogeneously hypoechoic; a complex echogenic pattern was observed with necrosis within the mass. Pleural effusion was a common finding in horses with mediastinal lymphosarcoma. Cytologic evaluation of pleural fluid samples was useful in diagnosis of lymphosarcoma in 10 of 12 horses that had thoracentesis. Sonographic examination of the thorax and cranial portion of the mediastinum can aid in the diagnosis of mediastinal lymphosarcoma in horses. Such examination should be performed in horses with clinical signs of cranial vena cava obstruction in which pleural effusion is detected, or when thoracic lymphosarcoma is suspected.

  19. Teaching Core Courses with a Focus on Rural Health. An Instructor Resource Guide. Appendix to a Final Report on the Paraprofessional Rurally Oriented Family Home Health Training Program.

    ERIC Educational Resources Information Center

    Myer, Donna Foster, Ed.

    This instructor's resource guide, one in a series of products from a project to develop an associate degree program for paraprofessional rural family health promoters, deals with teaching courses that focus on rural health. Discussed in the first section of the guide are the role of core courses in rural health promotional training and the…

  20. Core Competencies for Early Care and Education Professionals in Kansas and Missouri: What Professionals Who Work with Young Children and Families Need To Know and Are Able To Do To Provide Quality Early Care and Education.

    ERIC Educational Resources Information Center

    Metropolitan Council on Child Care, Kansas City, MO.

    This guide details the core competencies for early care and education professionals in Kansas and Missouri. The guide's introduction provides background information about what core competencies are, why they are important, and how they can be used by practitioners, directors, trainers, higher education faculty, agencies, and professional…

  1. Fine Arts: Music Core Curriculum, Grades 7-12.

    ERIC Educational Resources Information Center

    Utah State Office of Education, Salt Lake City.

    This guide delineates Utah's secondary school music course curricula. The introductory section, "Music Connections," contains a music achievement portfolio for a general music course. The guide explains that "Music Connections" is an extension of the K-6 music core and includes concepts and skills to integrate music into…

  2. Antenatal diagnosis of complete facial duplication--a case report of a rare craniofacial defect.

    PubMed

    Rai, V S; Gaffney, G; Manning, N; Pirrone, P G; Chamberlain, P F

    1998-06-01

    We report a case of the prenatal sonographic detection of facial duplication, the diprosopus abnormality, in a twin pregnancy. The characteristic sonographic features of the condition include duplication of eyes, mouth, nose and both mid- and anterior intracranial structures. A heart-shaped abnormality of the cranial vault should prompt more detailed examination for other supportive features of this rare condition.

  3. Faraday spectroscopy of ultracold atoms guided in hollow core optical fibers

    NASA Astrophysics Data System (ADS)

    Fatemi, Fredrik; Pechkis, Joseph

    2013-05-01

    We have performed spatially and temporally resolved magnetometry using Faraday spectroscopy of ultracold rubidium atoms confined in hollow core optical fibers. We first guide 105 Rb atoms into a 3-cm-long, 100-micron-core hollow fiber using blue-detuned hollow waveguide modes. Inside the fiber, the atoms are exposed to an optical pumping pulse, and the Larmor precession is monitored by the polarization rotation of a probe laser beam detuned by 50 GHz. The intense guide beams can perturb the detected Larmor precession frequencies, but we show that by confining the atoms to the intensity null of higher order blue-detuned hollow modes, these perturbations are reduced by over 95% compared to red-detuned guides. By adjusting the guide beam detuning and polarization, the deleterious effects of both photon scattering and frequency shifts can be suppressed such that multiple magnetic field measurements with sensitivity of 30 nT per sampling pulse can be obtained throughout the length of the fiber in a single loading cycle. Work supported by ONR and DARPA.

  4. Detection Rate and Sonographic Signs of Trisomy 21 Fetuses at 14-17 Weeks of Gestation.

    PubMed

    Bronshtein, Eliezer; Solt, Ido; Bronshtein, Moshe; Gover, Ayala; Wolman, Igal; Blumenfeld, Zeev

    2017-01-01

    Early prenatal ultrasound is an important part of prenatal screening in Israel. No studies have described the rate of trisomy 21 [T21] identification at 14-17 weeks gestation. To describe the rate of T21 identification by transvaginal sonograms (TVS) at 14-17 weeks gestation. We conducted a historical prospective study. Since 1986, early TVS of 72,000 fetuses at 14-17 weeks gestation have been prospectively recorded together with prenatal screening data at a private ultrasound center (AL-KOL, Haifa). We calculated the fraction of T21 cases by dividing the total number of cases with abnormal sonographic findings by the total number of diagnosed T21 cases. We also examined the percentage of verified T21 cases that had completely normal prenatal screening tests prior to the early prenatal TVS, thus revealing the contribution of this examination to the existing prenatal screening. Fisher's exact test was used to calculate odds ratios for each sonographic marker. Of 137 T21 fetuses, 123 had sonographic markers on early TVS, yielding a prediction capability of at least 89.87%. Of all T21 cases, 14% had completely normal nuchal translucency/first-trimester screening prior to the abnormal 14-17 week TVS findings. Isolated abnormal sonographic findings, which were found to increase the risk for T21, were common atrioventricular septal canal (odds ratio 88.88), duodenal atresia (OR 88.23), nuchal edema (OR 39.14), and hydrocephalus (OR 15.78). Fetal hydronephrosis/pyelectasis was non-significant when isolated (OR 1), and cardiac echogenic focus was associated with a decreased risk (OR 0.13). Early prenatal TVS at 14-17 weeks may identify almost 90% of T21 and adds 14% to the identification rate at the first-trimester screening.

  5. Extension of the Thoracic Spine Sign: A New Sonographic Marker of Pleural Effusion.

    PubMed

    Dickman, Eitan; Terentiev, Victoria; Likourezos, Antonios; Derman, Anna; Haines, Lawrence

    2015-09-01

    Dyspnea is a common emergency department (ED) condition, which may be caused by pleural effusion and other thoracic diseases. We present data on a new sonographic marker, the extension of the thoracic spine sign, for diagnosis of pleural effusion. In this prospective study, we enrolled a convenience sample of undifferentiated patients who underwent computed tomography (CT) of the abdomen or chest, which was performed as part of their emergency department evaluations. Patients underwent chest sonography to assess the utility of the extension of the thoracic spine sign for diagnosing pleural effusion. The point-of-care sonographic examinations were performed and interpreted by emergency physicians who were blinded to information in the medical records. Sonographic results were compared to radiologists' interpretations of the CT results, which were considered the criterion standard. Forty-one patients were enrolled, accounting for 82 hemithoraces. Seven hemithoraces were excluded from the analysis due to various limitations, leaving 75 hemithoraces for the final analysis. The median time for completion of the sonographic examination was 3 minutes. The sensitivity and specificity for extension of the thoracic spine were 73.7% (95% confidence interval [CI], 48.6%-89.9%) and 92.9% (95%CI, 81.9%-97.7%), respectively. Overall, there were 5 hemithoraces with false-negative results when using the extension sign. Of those 5 cases, 4 were found to have trace pleural effusions on CT. When trace pleural effusions were excluded in a subgroup analysis, the sensitivity and specificity of extension of the thoracic spine were 92.9% (95% CI, 64.2%-99.6%) and 92.9% (95% CI, 81.9%-97.7%). We found the extension of the thoracic spine sign to be an excellent diagnostic tool for clinically relevant pleural effusion. © 2015 by the American Institute of Ultrasound in Medicine.

  6. Parameters Associated with Adverse Fetal Outcomes in Parvovirus B19 Congenital Infection.

    PubMed

    Agra, Isabela Karine Rodrigues; Amorim Filho, Antonio Gomes; Lin, Lawrence Hsu; Biancolin, Sckarlet Ernandes; Francisco, Rossana Pulcineli Vieira; Brizot, Maria de Lourdes

    2017-11-01

    Objective  To investigate the clinical and sonographic parameters associated with adverse fetal outcomes in patients with congenital parvovirus B19 infection managed by intrauterine transfusion. Methods  This was a single-center retrospective study conducted from January 2005 to December 2016 that assessed patients with singleton pregnancies with fetal parvovirus infection confirmed by a polymerase chain reaction of the amniotic fluid or fetal blood samples who underwent at least one intrauterine transfusion. The maternal characteristics, sonographic findings and parameters related to intrauterine transfusion were compared between the two groups (recovery/non-recovery), who were categorized based on fetal response after in-utero transfusions. Progression to fetal death or delivery without fetal recovery after the transfusions was considered non-recovery and categorized as an adverse outcome. Results  The final analysis included ten singleton pregnancies: seven of which were categorized into the recovery group and three of which into the non-recovery group. The baseline characteristics were similar between the groups. All fetuses were hydropic at the time of diagnosis. No significant differences related to sonographic or intrauterine transfusion parameters were identified between the groups; however, the non-recovery group tended to have an increased number of sonographic markers and lower fetal hemoglobin and platelet levels before the transfusion. Conclusion  We were unable to firmly establish the clinical or sonographic parameters associated with adverse fetal outcomes in patients with parvovirus infection managed with intrauterine transfusions; however, edema, placental thickening and oligohydramnios may indicate greater fetal compromise and, subsequently, adverse outcomes. However, further studies are necessary, mainly due to the small number of cases analyzed in the present study. Thieme Revinter Publicações Ltda Rio de Janeiro, Brazil.

  7. Mondor's disease of the breast as a complication of ultrasound-guided core needle biopsy: management and review of the literature.

    PubMed

    Salemis, Nikolaos S; Vasilara, Georgia; Lagoudianakis, Emmanuel

    2015-01-01

    Mondor's disease is a rare benign and self-limiting condition characterized by thrombophlebitis of the superficial veins of the anterolateral thoracoabdominal wall. We describe a case of Mondor's disease of the breast as a complication of an ultrasound-guided core needle biospy. The patient presented with a palpable cord-like structure in her left breast, associated with severe pain and tenderness. She was treated concervatively and complete resolution was observed after four weeks. We conclude that emergency clinicians and interventional breast radiologists should be aware of Mondor's disease as a potential complication of ultrasound-guided core needle biopsy of the breast.

  8. Association of achondroplasia with Down syndrome: difficulty in prenatal diagnosis by sonographic and 3-D helical computed tomographic analyses.

    PubMed

    Kaga, Akimune; Murotsuki, Jun; Kamimura, Miki; Kimura, Masato; Saito-Hakoda, Akiko; Kanno, Junko; Hoshi, Kazuhiko; Kure, Shigeo; Fujiwara, Ikuma

    2015-05-01

    Achondroplasia and Down syndrome are relatively common conditions individually. But co-occurrence of both conditions in the same patient is rare and there have been no reports of fetal analysis of this condition by prenatal sonographic and three-dimensional (3-D) helical computed tomography (CT). Prenatal sonographic findings seen in persons with Down syndrome, such as a thickened nuchal fold, cardiac defects, and echogenic bowel were not found in the patient. A prenatal 3-D helical CT revealed a large head with frontal bossing, metaphyseal flaring of the long bones, and small iliac wings, which suggested achondroplasia. In a case with combination of achondroplasia and Down syndrome, it may be difficult to diagnose the co-occurrence prenatally without typical markers of Down syndrome. © 2014 Japanese Teratology Society.

  9. Prenatal sonographic diagnosis of diastrophic dwarfism.

    PubMed

    Tongsong, Theera; Wanapirak, Chanane; Sirichotiyakul, Supatra; Chanprapaph, Pharuhas

    2002-02-01

    A healthy 27-year-old pregnant woman underwent sonographic examination because her uterine size was large for 20 weeks' menstrual age. Sonograms showed short fetal limbs with hitchhiker thumbs and toes, thoracic scoliosis, clubbed feet, and polyhydramnios. The ossification of all bony structures appeared normal, and there was no evidence of fractures. On the basis of these sonographic findings, we diagnosed skeletal dysplasia and short-limbed dwarfism, most likely diastrophic dwarfism. We counseled the parents, and the pregnancy was continued. At 37 weeks menstrual age, the patient vaginally delivered a male infant that weighed 2,560 g. The infant survived with respiratory support during his first few days of life. Postnatal physical and radiologic examinations confirmed the prenatal diagnosis of diastrophic dwarfism. Sonography is the modality of choice for prenatal detection of diastrophic dwarfism. Copyright 2002 John Wiley & Sons, Inc.

  10. An ergonomic, instrumented ultrasound probe for 6-axis force/torque measurement.

    PubMed

    Gilbertson, Matthew W; Anthony, Brian W

    2013-01-01

    An ergonomic, instrumented ultrasound probe has been developed for medical imaging applications. The device, which fits compactly in the hand of sonographers and permits rapid attachment & removal of the ultrasound probe, measures ultrasound probe-to-patient contact forces and torques in all six axes. The device was used to measure contact forces and torques applied by ten professional sonographers on five patients during thirty-six abdominal exams. Of the three contact forces, those applied along the probe axis were found to be largest, averaging 7.0N. Measurement noise was quantified for each axis, and found to be small compared with the axial force. Understanding the range of forces applied during ultrasound imaging enables the design of more accurate robotic imaging systems and could also improve understanding of the correlation between contact force and sonographer fatigue and injury.

  11. Idiopathic club foot treated with the Ponseti method. Clinical and sonographic evaluation of Achilles tendon tenotomy. A review of 221 club feet.

    PubMed

    Marleix, S; Chapuis, M; Fraisse, B; Tréguier, C; Darnault, P; Rozel, C; Rayar, M; Violas, P

    2012-06-01

    The Ponseti method applied to treating idiopathic club foot consists in placing successive corrective casts, possibly an Achilles tendon tenotomy, then derotation braces, a method that has proven its efficacy. This study compared 221 cases of club foot treated with this method between 2002 and 2007 divided into two groups, based on whether or not Achilles tendon tenotomy was performed. Assessment was both clinical and sonographic. We observed clear improvement of the results in the group that underwent Achilles tendon tenotomy and a significant difference in the rate of secondary surgery. The sonographic evaluation also showed improvement of the morphological results. We now systematically propose Achilles tendon tenotomy however severe club foot may be. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  12. Flexible, liquid core light guide with focusing and light shaping attachments

    DOEpatents

    Wojcik, Randolph Frank; Majewski, Stanislaw; Zorn, Carl John; Kross, Brian

    1999-01-01

    A liquid light guide system for ultraviolet light is disclosed that has a light shaping arrangement for the emitted light, a stable liquid core and sheath and reliable and effective end closures. The end closures include a metal crimping arrangement that utilizes two layers of deformable materials to prevent cracking of endplugs.

  13. Beef Production Unit for Agricultural Science I Core Curriculum. Instructor's Guide. AGDEX 420/10.

    ERIC Educational Resources Information Center

    Stewart, Bob R.; And Others

    This instructor's guide for a beef production unit contains five lessons that are designed to be taught in the Agricultural Science I core curriculum. Introductory materials include lists of performance objectives and competencies for the complete unit, suggestions for motivational technique/interest approach and evaluation, lists of references…

  14. Making It Happen: Common Core Standards

    ERIC Educational Resources Information Center

    National Council of Teachers of Mathematics, 2011

    2011-01-01

    This one-of-a-kind guide identifies and highlights the ways in which NCTM (National Council of Teachers of Mathematics) resources can support teachers as they implement and supplement the Common Core State Standards for Mathematics (CCSSM) in their states. The guide and accompanying charts are tools to help educators as they continue to make…

  15. Sheep Production Unit for Agricultural Science I Core Curriculum. Instructor's Guide. AGDEX 430/10.

    ERIC Educational Resources Information Center

    Brzozowski, Richard J.; Stewart, Bob R.

    This instructor's guide for a sheep production unit contains six lessons that are designed to be taught in the Agricultural Science I core curriculum. Introductory materials include lists of performance objectives and competencies for the complete unit, suggestions for motivational technique/interest approach and evaluation, lists of references…

  16. Development and Feasibility Testing of Image-Guided Minimally Invasive Tissue for Diagnosis Treatment of Benign and Malignant Breast Disease

    NASA Technical Reports Server (NTRS)

    Jeffrey, Stefanie S.

    1999-01-01

    Dr. Robert Mah and Dr. Stefanie Jeffrey worked on the development of the NASA Smart Probe in its application as a device to measure and interpret physiologic and image-based parameters of breast tissue. To date the following has been achieved: 1 . Choice of candidate sensors to be tested in breast tissue. 2. Preliminary designs for probe tip, specifically use of different tip shapes, cutting edges, and sensor configuration. 3. Design of sonographic guidance system. 4. Design of data extraction and analysis tool using scanned information of images of the breast tissue to provide a higher dimension of information for breast tissue characterization and interpretation. 5. Initial ex-vivo (fruit and tofu) and in-vivo (rodent) testing to confirm unique substance and tissue characterization by the Smart Probe software.

  17. Starry sky sign: A prevalent sonographic finding in mediastinal tuberculous lymph nodes.

    PubMed

    Alici, Ibrahim Onur; Demirci, Nilg N Yilmaz; Yilmaz, Aydin; Karakaya, Jale; Erdogan, Yurdanur

    2015-01-01

    We report a prevalent finding in tuberculous lymphadenitis (TL): Starry sky sign, hyperechoic foci without acoustic shadows over a hypoechoic background. We retrospectively searched the database for a possible relationship of starry sky sign with a specific diagnosis and also the prevalence and accuracy of the finding. Starry sky sign was found in 16 of 31 tuberculous lymph nodes, while none of other lymph nodes (1,015 lymph nodes) exhibited this finding; giving a sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of 51.6%, 100%, 100%, 98.5%, and 98.5%, respectively. Bacteriologic and histologic findings are gold standard in the diagnosis of tuberculosis, but this finding may guide the bronchoscopist in choosing the more pathologic node within a station and increase the diagnostic yield as it may relate to actively dividing mycobacteria.

  18. Portal hypertension: Imaging of portosystemic collateral pathways and associated image-guided therapy.

    PubMed

    Bandali, Murad Feroz; Mirakhur, Anirudh; Lee, Edward Wolfgang; Ferris, Mollie Clarke; Sadler, David James; Gray, Robin Ritchie; Wong, Jason Kam

    2017-03-14

    Portal hypertension is a common clinical syndrome, defined by a pathologic increase in the portal venous pressure. Increased resistance to portal blood flow, the primary factor in the pathophysiology of portal hypertension, is in part due to morphological changes occurring in chronic liver diseases. This results in rerouting of blood flow away from the liver through collateral pathways to low-pressure systemic veins. Through a variety of computed tomographic, sonographic, magnetic resonance imaging and angiographic examples, this article discusses the appearances and prevalence of both common and less common portosystemic collateral channels in the thorax and abdomen. A brief overview of established interventional radiologic techniques for treatment of portal hypertension will also be provided. Awareness of the various imaging manifestations of portal hypertension can be helpful for assessing overall prognosis and planning proper management.

  19. Portal hypertension: Imaging of portosystemic collateral pathways and associated image-guided therapy

    PubMed Central

    Bandali, Murad Feroz; Mirakhur, Anirudh; Lee, Edward Wolfgang; Ferris, Mollie Clarke; Sadler, David James; Gray, Robin Ritchie; Wong, Jason Kam

    2017-01-01

    Portal hypertension is a common clinical syndrome, defined by a pathologic increase in the portal venous pressure. Increased resistance to portal blood flow, the primary factor in the pathophysiology of portal hypertension, is in part due to morphological changes occurring in chronic liver diseases. This results in rerouting of blood flow away from the liver through collateral pathways to low-pressure systemic veins. Through a variety of computed tomographic, sonographic, magnetic resonance imaging and angiographic examples, this article discusses the appearances and prevalence of both common and less common portosystemic collateral channels in the thorax and abdomen. A brief overview of established interventional radiologic techniques for treatment of portal hypertension will also be provided. Awareness of the various imaging manifestations of portal hypertension can be helpful for assessing overall prognosis and planning proper management. PMID:28348478

  20. Sonographic appearance of a partial rupture of the supinator muscle.

    PubMed

    Chen, Chih-Chun; Chiou, Hong-Jen; Kao, Chung-Lan; Chan, Rai-Chi

    2008-05-01

    We report the case of a 51-year-old woman who experienced pain and swelling in the right forearm after spinning cotton. History taking and physical examinations helped identify a tear of the supinator muscle, which was confirmed via sonographic examination. To our knowledge, this article is the first report of a supinator muscle tear diagnosed with sonography. (c) 2008 Wiley Periodicals, Inc. J Clin Ultrasound, 2008.

  1. Computerized Tomography-Guided Paracentesis: An Effective Alternative to Bedside Paracentesis?

    PubMed

    Gaduputi, Vinaya; Tariq, Hassan; Chandrala, Chaitanya; Sakam, Sailaja; Abbas, Naeem; Chilimuri, Sridhar

    2017-02-01

    Ascites remains the most common cause of hospitalization among patients with decompensated cirrhosis. Paracentesis is a relatively safe procedure with low complication rates. Computerized tomography (CT)-guided therapeutic paracentesis could be a safe and effective alternative to unaided or aided (ultrasonogram-guided) bedside paracentesis. In this retrospective study, we aimed to compare the efficacy, safety, and cost-effectiveness of CT-guided paracentesis with bedside paracentesis. The period of study was from 2002 to 2012. All patients with cirrhosis who underwent therapeutic paracentesis were included in the study. These patients were divided into two groups. Group I consisted of patients who underwent CT-guided pigtail catheter insertion with ascitic fluid drainage. Group II consisted of patients who underwent beside therapeutic paracentesis after localization of fluid either by physical examination or sonographic localization. We measured the efficacy of CT-guided paracentesis and bedside paracentesis in terms of volume of fluid removed, length of stay, discharge doses of diuretics (spironolactone and furosemide) and number of days to readmission for symptomatic ascites. We also computed the cost-effectiveness of CT-guided therapeutic paracentesis when compared to a bedside procedure. Fischer exact test was used to analyze the distribution of categorical data and unpaired t -test was used for comparison of means. There were a total of 546 unique patients with diagnosed cirrhosis who were admitted to the hospital with symptomatic ascites and underwent therapeutic paracentesis. Two hundred and forty-seven patients underwent CT-guided paracentesis, while 272 patients underwent bedside paracentesis. There was significant inverse correlation between the amount of ascitic fluid removed and total length of stay in the hospital. We found that the volume of fluid removed via a CT-guided pigtail insertion and drainage (2.72 ± 2.02 L) is significantly higher when compared to fluid removed via bedside paracentesis (1.94 ± 1.69). We also found that the interval time period between two successive therapeutic paracenteses was significantly longer for CT group (106.56 ± 75.2 days) when compared to the bedside group (25.57 ± 7.68 days). CT-guided paracentesis with pigtail catheter insertion and drainage is a clinically effective, cheap and safe alternative to conventional bedside paracentesis.

  2. Ultrasonic Percutaneous Tenotomy for Recalcitrant Lateral Elbow Tendinopathy: Sustainability and Sonographic Progression at 3 Years.

    PubMed

    Seng, Chusheng; Mohan, P Chandra; Koh, Suang Bee Joyce; Howe, Tet Sen; Lim, Yee Gen; Lee, Brian P; Morrey, Bernard F

    2016-02-01

    A previously published study found positive outcomes for a novel technique for ultrasound-guided percutaneous ultrasonic tenotomy, showing good tolerability, safety, and early efficacy within an office setting. In this follow-up study, all 20 members of the original cohort were contacted after 3 years to explore the sustainability of symptomatic relief, functional improvement, and sonographic soft tissue response for percutaneous ultrasonic tenotomy. Case series; Level of evidence, 4. All 20 subjects of the clinical trial that was performed from June to November 2011 were further assessed at 36 months after the procedure in terms of visual analog scale for pain, Disabilities of the Arm, Shoulder and Hand (DASH)-Compulsory/Work scores, need for adjunct procedures, and overall satisfaction. Importantly, all 20 were reassessed with ultrasound imaging at 36 months, and evidence of the common extensor tendon response was assessed in terms of tendon hypervascularity, tendon thickness, and the progress of the hypoechoic scar tissue. A 100% clinical follow-up was achieved, inclusive of ultrasonographic assessment. None of the subjects required further treatment procedures, and 100% expressed satisfaction. Previous improvements in visual analog scale (current median ± SD, 0 ± 0.9; range, 0-3) and DASH-Work scores (current median, 0 ± 0) were sustained with conformity to a linear pattern on polynomial measures. There was further reduction in DASH-Compulsory scores to a median of 0 ± 0.644 (range, 0-2) with a significant decrease on repeated measures (P = .008). Tendon hypervascularity was resolved in 94% of patients, and 100% had reduction in tendon thickness. Overall reduction in the hypoechoic scar tissue was observed in all subjects, with a 90% response achieved by 6 months. Between 6 and 36 months, further reduction in the scar was observed in around 60% of patients, with 20% of patients having complete resolution of the hypoechoic scar. Minimally invasive percutaneous ultrasonic tenotomy provided sustained pain relief and functional improvement for recalcitrant tennis elbow at 3-year follow-up. It is one of the few procedures to demonstrate positive sonographic evidence of tissue-healing response and is an attractive alternative to surgical intervention for definitive treatment of recalcitrant elbow tendinopathy. © 2015 The Author(s).

  3. Suspended core subwavelength fibers: towards practical designs for low-loss terahertz guidance.

    PubMed

    Rozé, Mathieu; Ung, Bora; Mazhorova, Anna; Walther, Markus; Skorobogatiy, Maksim

    2011-05-09

    In this work we report two designs of subwavelength fibers packaged for practical terahertz wave guiding. We describe fabrication, modeling and characterization of microstructured polymer fibers featuring a subwavelength-size core suspended in the middle of a large porous outer cladding. This design allows convenient handling of the subwavelength fibers without distorting their modal profile. Additionally, the air-tight porous cladding serves as a natural enclosure for the fiber core, thus avoiding the need for a bulky external enclosure for humidity-purged atmosphere. Fibers of 5 mm and 3 mm in outer diameters with a 150 µm suspended solid core and a 900 µm suspended porous core respectively, were obtained by utilizing a combination of drilling and stacking techniques. Characterization of the fiber optical properties and the subwavelength imaging of the guided modes were performed using a terahertz near-field microscopy setup. Near-field imaging of the modal profiles at the fiber output confirmed the effectively single-mode behavior of such waveguides. The suspended core fibers exhibit transmission from 0.10 THz to 0.27 THz (larger core), and from 0.25 THz to 0.51 THz (smaller core). Due to the large fraction of power that is guided in the holey cladding, fiber propagation losses as low as 0.02 cm(-1) are demonstrated specifically for the small core fiber. Low-loss guidance combined with the core isolated from environmental perturbations make these all-dielectric fibers suitable for practical terahertz imaging and sensing applications. © 2011 Optical Society of America

  4. MRI/US fusion-guided prostate biopsy allows for equivalent cancer detection with significantly fewer needle cores in biopsy-naive men

    PubMed Central

    Yarlagadda, Vidhush K.; Lai, Win Shun; Gordetsky, Jennifer B.; Porter, Kristin K.; Nix, Jeffrey W.; Thomas, John V.; Rais-Bahrami, Soroush

    2018-01-01

    PURPOSE We aimed to investigate the efficiency and cancer detection of magnetic resonance imaging (MRI)/ultrasonography (US) fusion-guided prostate biopsy in a cohort of biopsy-naive men compared with standard-of-care systematic extended sextant transrectal ultrasonography (TRUS)-guided biopsy. METHODS From 2014 to 2016, 72 biopsy-naive men referred for initial prostate cancer evaluation who underwent MRI of the prostate were prospectively evaluated. Retrospective review was performed on 69 patients with lesions suspicious for malignancy who underwent MRI/US fusion-guided biopsy in addition to systematic extended sextant biopsy. Biometric, imaging, and pathology data from both the MRI-targeted biopsies and systematic biopsies were analyzed and compared. RESULTS There were no significant differences in overall prostate cancer detection when comparing MRI-targeted biopsies to standard systematic biopsies (P = 0.39). Furthermore, there were no significant differences in the distribution of severity of cancers based on grade groups in cases with cancer detection (P = 0.68). However, significantly fewer needle cores were taken during the MRI/US fusion-guided biopsy compared with systematic biopsy (63% less cores sampled, P < 0.001) CONCLUSION In biopsy-naive men, MRI/US fusion-guided prostate biopsy offers equal prostate cancer detection compared with systematic TRUS-guided biopsy with significantly fewer tissue cores using the targeted technique. This approach can potentially reduce morbidity in the future if used instead of systematic biopsy without sacrificing the ability to detect prostate cancer, particularly in cases with higher grade disease. PMID:29770762

  5. Flexible, liquid core light guide with focusing and light shaping attachments

    DOEpatents

    Wojcik, R.F.; Majewski, S.; Zorn, C.J.; Kross, B.

    1999-04-20

    A liquid light guide system for ultraviolet light is disclosed that has a light shaping arrangement for the emitted light, a stable liquid core and sheath and reliable and effective end closures. The end closures include a metal crimping arrangement that utilizes two layers of deformable materials to prevent cracking of endplugs. 19 figs.

  6. Sheep Stockmanship (Lambing). Youth Training Scheme. Core Exemplar Work Based Project.

    ERIC Educational Resources Information Center

    Further Education Staff Coll., Blagdon (England).

    This trainer's guide is intended to assist supervisors of work-based career training projects in helping students gather and record information about sheep breeding, learn about treatment of diseases, prepare the lambing area, and assist with the aftercare of lambs and ewes. The guide is one in a series of core curriculum modules that is intended…

  7. Core III Materials for Rural Agriculture Programs. Units H-I.

    ERIC Educational Resources Information Center

    Courson, Roger L.; And Others

    This curriculum guide includes teaching packets for nine problem areas of study to be included in a core curriculum for 11th-grade or third-year students enrolled in rural agricultural programs in Illinois. Each problem area includes some or all of the following components: suggestions to the teacher, a teacher guide, a competency inventory, an…

  8. What's the Flexitime? Youth Training Scheme. Core Exemplar Work Based Project.

    ERIC Educational Resources Information Center

    Further Education Staff Coll., Blagdon (England).

    This trainer's guide is intended to assist supervisors of work-based career training projects in helping students understand the advantages and disadvantages of flexitime as opposed to other methods of timekeeping and explore the criteria for determining wages. The guide is one in a series of core curriculum modules that is intended for use in…

  9. The Common Sense Guide to the Common Core: Teacher-Tested Tools for Implementation

    ERIC Educational Resources Information Center

    McKnight, Katherine

    2014-01-01

    Based on the original source document for the Common Core State Standards and tested by 1,000 educators in diverse classrooms across the country, these research-based tools will help readers examine their current practices and adapt existing curriculum. Each of the 40 tools is clearly presented, explained, and exemplified, guiding educators…

  10. Beef Production for Agricultural Science I Core Curriculum. Student Reference. AGDEX 420/10.

    ERIC Educational Resources Information Center

    Missouri Univ., Columbia. Instructional Materials Lab.

    This student reference booklet is designed to accompany lessons outlined in the companion instructor's guide on beef production. Together, the student reference and instructor's guide form part of the Animal Science I core curriculum. This unit on beef production is divided into five lessons in these areas: selection of breeding stock, breeding…

  11. Common Core Standards for High School Mathematics: A Quick-Start Guide

    ERIC Educational Resources Information Center

    Dempsey, Kathleen; Schwols, Armitra

    2012-01-01

    Shifting your high school's math program to new Common Core standards is much easier when teachers and leaders have this handy guide. Getting a copy for every staff member involved in the process ensures everyone knows: (1) How the six conceptual categories throughout the math standards are connected and reinforced; (2) How the modeling standards…

  12. Fire. Youth Training Scheme. Core Exemplar Work Based Project.

    ERIC Educational Resources Information Center

    Further Education Staff Coll., Blagdon (England).

    This trainer's guide is intended to assist supervisors of work-based career training projects in teaching students the basics of fire prevention in the kitchen. The guide is one in a series of core curriculum modules that is intended for use in combination on- and off-the-job programs to familiarize youth with the skills, knowledge, and attitudes…

  13. Core IV Materials for Rural Agriculture Programs. Units A-G.

    ERIC Educational Resources Information Center

    Courson, Roger; And Others

    This curriculum guide, the first part of a core curriculum for a rural agriculture program, consists of materials for use in presenting the first seven units of a nine-unit course for high school vocational agriculture students living in rural areas. Addressed in the individual units of the guide are the following topics: educational and…

  14. Core III Materials for Rural Agriculture Programs. Units A-G.

    ERIC Educational Resources Information Center

    Courson, Roger L.; And Others

    This curriculum guide includes teaching packets for 12 areas of study to be included in a core curriculum for 11th-grade or third-year students enrolled in rural agricultural programs in Illinois. Each problem area includes some or all of the following components: suggestions to the teacher, teacher guide, competency inventory, information sheet,…

  15. Sonographic and MR features of puerperal uterine inversion.

    PubMed

    Thakur, Shruti; Sharma, Sanjiv; Jhobta, Anupam; Aggarwal, Neeti; Thakur, Charu S

    2014-06-01

    Puerperal uterine inversion is a rare and potentially life-threatening complication of a mismanaged third stage of labour. Early diagnosis is mandatory for proper management of the patient. Complete uterine inversion is a clinical diagnosis. However, incomplete uterine inversion is difficult to identify and warrants further workup. Sonographic evaluation, although a bedside procedure, may be confusing. The conspicuity of findings is much greater on MR examination than on ultrasound. Only a few diagnostic imaging findings in uterine inversion have been described in previous reports. We present the case of a 26-year-old woman who had a full-term vaginal delivery and presented after 20 days with acute urinary retention and mild vaginal bleeding. She was diagnosed as a case of neglected subacute incomplete uterine inversion. Both greyscale and Doppler sonographic and MR features of the case are described with an emphasis on better delineation of uterine and adnexal anatomy on MR imaging.

  16. Real-time three-dimensional optical coherence tomography image-guided core-needle biopsy system.

    PubMed

    Kuo, Wei-Cheng; Kim, Jongsik; Shemonski, Nathan D; Chaney, Eric J; Spillman, Darold R; Boppart, Stephen A

    2012-06-01

    Advances in optical imaging modalities, such as optical coherence tomography (OCT), enable us to observe tissue microstructure at high resolution and in real time. Currently, core-needle biopsies are guided by external imaging modalities such as ultrasound imaging and x-ray computed tomography (CT) for breast and lung masses, respectively. These image-guided procedures are frequently limited by spatial resolution when using ultrasound imaging, or by temporal resolution (rapid real-time feedback capabilities) when using x-ray CT. One feasible approach is to perform OCT within small gauge needles to optically image tissue microstructure. However, to date, no system or core-needle device has been developed that incorporates both three-dimensional OCT imaging and tissue biopsy within the same needle for true OCT-guided core-needle biopsy. We have developed and demonstrate an integrated core-needle biopsy system that utilizes catheter-based 3-D OCT for real-time image-guidance for target tissue localization, imaging of tissue immediately prior to physical biopsy, and subsequent OCT imaging of the biopsied specimen for immediate assessment at the point-of-care. OCT images of biopsied ex vivo tumor specimens acquired during core-needle placement are correlated with corresponding histology, and computational visualization of arbitrary planes within the 3-D OCT volumes enables feedback on specimen tissue type and biopsy quality. These results demonstrate the potential for using real-time 3-D OCT for needle biopsy guidance by imaging within the needle and tissue during biopsy procedures.

  17. Comparison of clinical marking and ultrasound-guided injection of Botulinum type A toxin into the masseter muscles for treating bruxism and its cosmetic effects.

    PubMed

    Quezada-Gaon, Natacha; Wortsman, Ximena; Peñaloza, Osvaldo; Carrasco, Juan Eduardo

    2016-09-01

    Botulinum toxin type A has been used for treating the hypertrophy of the masseter muscles and its cosmetic effects. Ultrasound is increasingly used in dermatology, along with the guidance of mini-invasive procedures. To evaluate the role of ultrasound for guiding the application of Botulinum A toxin in patients with cosmetic alterations due to bruxism, correlate the clinical landmarks with the ultrasound findings, and study the effect on the symptoms, cosmetics, and quality of life. Twenty individuals with bruxism and cosmetic alterations underwent an ultrasound-guided injection of Botulinum toxin type A in each masseter muscle. Clinical and ultrasound marking of the procedure was compared. Clinical and sonographic evaluation was performed at the time of injection and 3 months later. Ten normal individuals underwent ultrasound of the masseter muscles as a control group. Up to 65% of individuals showed anatomical variants of the salivary glands. The method for clinically marking the skin showed a frequently erroneous location of the anterior point (up to 40% of cases) that was proven by ultrasound to be out of the muscle. In 20% of cases, ultrasound showed that the needle should be longer to enter the muscle. After injection, most of the patients demonstrated a decrease of the symptoms and cosmetic and quality of life improvements. Ultrasound can be a potent tool for guiding the injection of Botulinum toxin into the masseter muscles. It may contribute to a more personalized procedure, better cosmetic results, and help to avoid potential complications. © 2016 Wiley Periodicals, Inc.

  18. A technique for ultrasound-guided blood sampling from a dry and gel-free puncture area.

    PubMed

    Thorn, Sofie; Gopalasingam, Nigopan; Bendtsen, Thomas Fichtner; Knudsen, Lars; Sloth, Erik

    2016-05-07

    Vein punctures are performed daily to sample blood. Ultrasound (US) offers an alternative to the blind landmark technique for difficult vascular access. A challenge for this procedure is the presence of US gel in the puncture area. We present a technique for US-guided puncture from extremity veins not palpable or visible to the human eye, while keeping the puncture area dry and gel-free. Ten healthy volunteers underwent two US-guided vein punctures from veins that were neither palpable nor visible. One was drawn from an antebrachial vein and another from a brachial vein. A sterile barrier drape was made from a commercially available dressing and a piece of transparent sterile plastic. The barrier drape consists of an adhesive part placed on the skin designed for sonography and a free transparent flap constituting the barrier between the unsterile sonographic site and the sterile gel-free puncture site. The success rate for vein puncture was 100% in both locations. A total of 22 skin punctures were performed (11 antebrachial and 11 brachial). Gain output was increased 7% (4-12%), and 8% (4-15%), respectively, to compensate for attenuation of the US signal due to the drape. Alignment of the centre of the transducer with the long-axis of the target vein during the procedure was reported as a challenge. US-guided blood sampling from a brachial and antebrachial vein was possible with a 100% success rate, while ensuring a dry and gel-free venipuncture area on one side and the transducer on the other side of a sterile barrier.

  19. Ten-core versus 16-core transrectal ultrasonography guided prostate biopsy for detection of prostatic carcinoma: a prospective comparative study in Indian population

    PubMed Central

    Prakash, V. Surya; Mohan, G. Chandra; Krishnaiah, S. Venkata; Vijaykumar, V.; Babu, G. Ramesh; Reddy, G. Vijaya Bhaskar; Mahaboob, V. S.

    2013-01-01

    Purpose: To compare the cancer detection rate in patients with raised serum prostate-specific antigen (PSA) or abnormal digital rectal examination (DRE) results between the 10-core and the 16-core biopsy techniques in an Indian population. Methods: Between November 2010 and November 2012, 95 men aged >50 years who presented to the Urology Department with lower urinary tract symptoms, elevated serum PSA, and/or abnormal DRE findings underwent transrectal ultrasonography (TRUS)-guided prostate biopsy. A total of 53 patients underwent 10-core biopsy and 42 patients underwent 16-core biopsy. Results: Of the 53 men in the 10-core group, 8 had cancer, whereas in the 16-core biopsy group, 23 of 42 men had cancer. Detection of prostate cancer was significantly higher in patients who underwent 16-core biopsy than in those who underwent 10-core biopsy (P<0.001). Among the 95 men, 44 men had abnormal DRE findings (46.3%), of whom 23 showed cancer (52.27%). Of 51 men with normal DRE findings and elevated PSA, 8 men had malignancy with a cancer detection rate of 15.68%. Among 20 men with PSA between 4.1 and 10 ng/mL, 2 (10%) had cancer. In 31 men with PSA between 10.1 and 20 ng/mL, 3 cancers (9.67%) were detected, and in 44 men with PSA >20 ng/mL, 26 cancers were detected (59.09%). Conclusions: The cancer detection rate with 16-core TRUS-guided biopsy is significantly higher than that with 10-core biopsy (54.76% vs. 15.09%, P<0.001). In patients with both normal and abnormal DRE findings, 16-core biopsy has a better detection rate than the 10-core biopsy protocol. With increasing PSA, there is a high rate of detection of prostate cancer in both 10-core and 16-core biopsy patients. PMID:24392441

  20. Ten-core versus 16-core transrectal ultrasonography guided prostate biopsy for detection of prostatic carcinoma: a prospective comparative study in Indian population.

    PubMed

    Prakash, V Surya; Mohan, G Chandra; Krishnaiah, S Venkata; Vijaykumar, V; Babu, G Ramesh; Reddy, G Vijaya Bhaskar; Mahaboob, V S

    2013-01-01

    To compare the cancer detection rate in patients with raised serum prostate-specific antigen (PSA) or abnormal digital rectal examination (DRE) results between the 10-core and the 16-core biopsy techniques in an Indian population. Between November 2010 and November 2012, 95 men aged >50 years who presented to the Urology Department with lower urinary tract symptoms, elevated serum PSA, and/or abnormal DRE findings underwent transrectal ultrasonography (TRUS)-guided prostate biopsy. A total of 53 patients underwent 10-core biopsy and 42 patients underwent 16-core biopsy. Of the 53 men in the 10-core group, 8 had cancer, whereas in the 16-core biopsy group, 23 of 42 men had cancer. Detection of prostate cancer was significantly higher in patients who underwent 16-core biopsy than in those who underwent 10-core biopsy (P<0.001). Among the 95 men, 44 men had abnormal DRE findings (46.3%), of whom 23 showed cancer (52.27%). Of 51 men with normal DRE findings and elevated PSA, 8 men had malignancy with a cancer detection rate of 15.68%. Among 20 men with PSA between 4.1 and 10 ng/mL, 2 (10%) had cancer. In 31 men with PSA between 10.1 and 20 ng/mL, 3 cancers (9.67%) were detected, and in 44 men with PSA >20 ng/mL, 26 cancers were detected (59.09%). The cancer detection rate with 16-core TRUS-guided biopsy is significantly higher than that with 10-core biopsy (54.76% vs. 15.09%, P<0.001). In patients with both normal and abnormal DRE findings, 16-core biopsy has a better detection rate than the 10-core biopsy protocol. With increasing PSA, there is a high rate of detection of prostate cancer in both 10-core and 16-core biopsy patients.

  1. Looking after Lawns and Bedding. Youth Training Scheme. Core Exemplar Work Based Project.

    ERIC Educational Resources Information Center

    Further Education Staff Coll., Blagdon (England).

    This trainer's guide is intended to assist supervisors of work-based career training projects in teaching students about lawn care. The guide is one in a series of core curriculum modules that is intended for use in combination on- and off-the-job programs to familiarize youth with the skills, knowledge, and attitudes necessary for success in the…

  2. Core Curriculum in Preventing and Reducing School Violence and Vandalism. Course 4: Interpersonal Relations. Participant Guide and Reference Notebook.

    ERIC Educational Resources Information Center

    Center for Human Services, Washington, DC.

    This guide, intended for participants in the fourth course of the National School Resource Network Core Curriculum, contains an activity/content summary for each module of the course, worksheets, and background materials. The purpose of this course is to introduce approaches and resources to identify, manage, reduce, resolve, and prevent crisis…

  3. Don't Eat Germs! Youth Training Scheme. Core Exemplar Work Based Project.

    ERIC Educational Resources Information Center

    Further Education Staff Coll., Blagdon (England).

    This trainer's guide is intended to assist supervisors of work-based career training projects in helping students understand and control the causes of contamination and food poisoning. The guide is one in a series of core curriculum modules that is intended for use in combination on- and off-the-job programs to familiarize youth with the skills,…

  4. Use of a Microwave Oven. Youth Training Scheme. Core Exemplar Work Based Project.

    ERIC Educational Resources Information Center

    Further Education Staff Coll., Blagdon (England).

    This trainer's guide is intended to assist supervisors of work-based career training projects in helping students understand the benefits, advantages, and disadvantages of a microwave oven and its use. The guide is one in a series of core curriculum modules that is intended for use in combination on- and off-the-job programs to familiarize youth…

  5. Common Core Standards for High School English Language Arts: A Quick-Start Guide

    ERIC Educational Resources Information Center

    Kendall, John; Frazee, Dana; Ryan, Susan

    2012-01-01

    High school teachers and leaders with responsibility for English language arts (ELA) need this handy guide to successfully implement the Common Core in their respective grade levels. Getting a copy for every staff member ensures they know: (1) How grades 11-12 ELA content differs from and builds upon 9-10 standards; (2) How the four strands…

  6. Using the Illinois Core Curriculum for Developing Courses of Study in Vocational Agriculture.

    ERIC Educational Resources Information Center

    Osborne, Ed; Hemp, Paul

    This booklet is designed to serve as a practical guide to assist teachers in using the Illinois Core Curriculum in Agriculture to develop courses of study for local vocational agriculture courses. Provided first is an overview of vocational agriculture programs on the secondary-school level in the state of Illinois. The next section is a guide for…

  7. Production Line Materials. Youth Training Scheme. Core Exemplar Work Based Project.

    ERIC Educational Resources Information Center

    Further Education Staff Coll., Blagdon (England).

    This trainer's guide is intended to assist supervisors of work-based career training projects in helping students understand the operation of an assembly line, including safe working procedures. The guide is one in a series of core curriculum modules that is intended for use in combination on- and off-the-job programs to familiarize youth with the…

  8. Pancreatic changes in cystic fibrosis: CT and sonographic appearances

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daneman, A.; Gaskin, K.; Martin, D.J.

    1983-10-01

    The computed tomographic (CT) and sonographic appearances of the late stages of pancreatic damage in three patients with cystic fibrosis are illustrated. All three had severe exocrine pancreatic insufficiency with steatorrhea. In two patients CT revealed complete fatty replacement of the entire pancreas. In the third, increased echogenicity of the pancreas on sonography and the inhomogeneous attenuation on CT were interpreted as being the result of a combination of fibrosis, fatty replacement, calcification, and probable cyst formation.

  9. [Sonographic semiotics of ureterohydronephrosis in children].

    PubMed

    Khakkulov, E B

    2016-04-01

    To identify typical sonographic semiotics of ureterohydronephrosis in children having importance in determining the severity of disease and the choice of treatment strategy in this category of patients. Sonographic images of the kidneys and urinary tract of 158 children with ureterohydronephrosis were examined. Unilateral and bilateral ureterohydronephrosis was found in 75 and 83 children, respectively. There were 100 (63.3%) boys and 58 (36.7%) girls. The age of patients ranged from 3 months to 14 years (mean 4.15+/-3.21). Ultrasound examination enables the upper 193 (80.1%) and lower 167 (69.3%) third of ureters to be visualized. At the same time more than half of the visualized ureters had a diameter greater than 1 cm, and one-tenth of the affected ureters had diameters greater than 2 cm. If direct visualization of the ureters was impossible, pelvicalyceal system was evaluated, which was expanded on the affected side in all examined children. The morpho-sonographic changes of renal parenchymal in children with III-IV degree ureterohydronephrosis are described in details. Ultrasound examination can be regarded as a screening method for initial evaluation of patients with ureterohydronephrosis. It provides a rough estimation of the extent, level and nature of disturbances of urinary excretion, a preliminary assessment of the renal parenchyma and identification of anomalies of the urinary tract. These findings can be useful in choosing an optimal algorithm of diagnosis and surgical treatment of the disease.

  10. Sonographic features of thyroid nodules that may help distinguish clinically atypical subacute thyroiditis from thyroid malignancy.

    PubMed

    Pan, Fu-shun; Wang, Wei; Wang, Yan; Xu, Ming; Liang, Jin-yu; Zheng, Yan-ling; Xie, Xiao-yan; Li, Xiao-xi

    2015-04-01

    The purpose of this study was to evaluate sonographic features for distinguishing clinically atypical subacute thyroiditis from malignant thyroid nodules. A total of 165 hypoechoic thyroid nodules without calcification in 135 patients with histologic diagnosis were included in this study. These nodules were classified into 2 groups: a thyroiditis group (55 nodules in 36 patients) and a malignancy group (110 nodules in 99 patients). The sonographic features of the groups were retrospectively reviewed. No significant differences were detected for the variables of marked echogenicity, a taller-than-wide shape, and mixed vascularity. However, a poorly defined margin was detected more frequently in the thyroiditis group than the malignancy group (P < .05); it yielded a high capability for differential diagnosis of atypical subacute thyroiditis, with sensitivity and specificity of 87.3% and 80.9%, respectively. Centripetal reduction echogenicity was observed exclusively in the thyroiditis group, with high specificity (100%) but low sensitivity (21.8%) for atypical subacute thyroiditis diagnosis. All of the thyroiditis nodules with a positive color signal showed noninternal vascularity (negative predictive value, 100%). There is a considerable overlap between the sonographic features of atypical subacute thyroiditis and thyroid malignancy. However, the margin, echogenicity, and vascularity type are helpful indicators for differential diagnosis of atypical subacute thyroiditis. © 2015 by the American Institute of Ultrasound in Medicine.

  11. In Vivo High-Frequency Contrast-Enhanced Ultrasonography of Choroidal Melanoma in Rabbits: Imaging Features and Histopathologic Correlations

    PubMed Central

    Kang, Shin J.; Zhang, Qing; Patel, Samirkumar R.; Berezovsky, Damian; Yang, Hua; Wang, Yanggan; Grossniklaus, Hans E.

    2013-01-01

    Purpose To evaluate the utility of in vivo imaging of rabbit model of choroidal melanoma utilizing high-frequency contrast-enhanced ultrasound (HF-CE-US) with 2-or 3-dimensional modes, and to correlate the sonographic findings with histopathologic characteristics. Methods Five New Zealand white rabbits which were immunosuppressed with daily cyclosporin A were inoculated into their right eyes with aliquots of 1.5×106 / 50 µL of 92.1 human uveal melanoma cells cultured in RPMI. At week 4, the tumor-bearing eyes were imaged using high-frequency ultrasound with microbubble contrast agent to determine the 2-dimensional tumor size and relative blood volume and by 3-dimensional mode to determine tumor volume. Histologic tumor burden was quantified in enucleated eyes by ImageJ software, and microvascular density (MVD) was determined by counting vascular channels in PAS without hematoxylin sections. Results Utilizing HF-CE-US, melanomas were visualized as relatively hyperechoic regions in the images. The correlation coefficients of sonographic size or volume compared with histologic area were 0.72 and 0.70, respectively. The sonographic tumor relative blood volume correlated with the histologic tumor vascularity (R2=0.92, P=0.04) Conclusions There is a positive correlation between in vivo sonographic tumor volume/size and histologic tumor size in our rabbit choroidal melanoma model. HF-CE-US corresponds to microvascular density and blood volume. PMID:23645822

  12. Percutaneous alcohol injection under sonographic guidance in Morton's neuroma: follow-up in 220 treated lesions.

    PubMed

    Perini, Luciano; Perini, Claudia; Tagliapietra, Matteo; Varotto, Davide; Valcarenghi, Andrea; Postorino, Andrea; Volpe, Antonio

    2016-07-01

    To evaluate the efficacy and safety of percutaneous treatment of Civinini-Morton's syndrome due to solitary Morton's neuroma and analyze the effect of clinico-demographic factors on outcome. Alcohol injection was performed under sonographic guidance in 220 consecutive patients. Pain intensity using a numerical rating scale (NRS), pain features, limitation of everyday activities and comorbidity with other forefoot conditions were evaluated at presentation. Patients were reassessed for symptoms and the need of rescue therapy with neurectomy after a mean follow-up of 19.0 months (range 15-24). We treated 220 patients (33 males, mean age 55.8 years). Neuromas were located in the III intermetatarsal space in 85.5 %, with a mean size of 5.4 mm. When considering a reduction of pain intensity of ≥50 % of NRS or a complete disappearance of the neuropathic features as a satisfactory clinical response, a 72.3 % (p < 0.001) responder rate was obtained, and only three patients relapsed (1.2 %). An improvement in limitation of everyday activities was observed in 88.6 % (p < 0.001). No influence of clinico-demographic variables on outcome was found. No major complications occurred. Patients with unsatisfactory response had an overload-related comorbid condition in 20/61 (32.8 %). Surgery was later performed in 14 non-responder patients. Ultrasound-guided alcoholization demonstrated a safe profile, relieved neuropathic symptoms in a majority of patients and improved their quality of life. Rescue therapy with surgery is feasible in patients with unsatisfactory response. However, a thorough evaluation for forefoot comorbidities should be obtained, as they may act as confounding factors.

  13. Diagnostic ultrasound at MACH 20: retroperitoneal and pelvic imaging in space.

    PubMed

    Jones, J A; Sargsyan, A E; Barr, Y R; Melton, S; Hamilton, D R; Dulchavsky, S A; Whitson, P A

    2009-07-01

    An operationally available diagnostic imaging capability augments spaceflight medical support by facilitating the diagnosis, monitoring and treatment of medical or surgical conditions, by improving medical outcomes and, thereby, by lowering medical mission impacts and the probability of crew evacuation due to medical causes. Microgravity-related physiological changes occurring during spaceflight can affect the genitourinary system and potentially cause conditions such as urinary retention or nephrolithiasis for which ultrasonography (U/S) would be a useful diagnostic tool. This study describes the first genitourinary ultrasound examination conducted in space, and evaluates image quality, frame rate, resolution requirements, real-time remote guidance of nonphysician crew medical officers and evaluation of on-orbit tools that can augment image acquisition. A nonphysician crew medical officer (CMO) astronaut, with minimal training in U/S, performed a self-examination of the genitourinary system onboard the International Space Station, using a Philips/ATL Model HDI-5000 ultrasound imaging unit located in the International Space Station Human Research Facility. The CMO was remotely guided by voice commands from experienced, earth-based sonographers stationed in Mission Control Center in Houston. The crewmember, with guidance, was able to acquire all of the target images. Real-time and still U/S images received at Mission Control Center in Houston were of sufficient quality for the images to be diagnostic for multiple potential genitourinary applications. Microgravity-based ultrasound imaging can provide diagnostic quality images of the retroperitoneum and pelvis, offering improved diagnosis and treatment for onboard medical contingencies. Successful completion of complex sonographic examinations can be obtained even with minimally trained nonphysician ultrasound operators, with the assistance of ground-based real-time guidance.

  14. Ultrasound measurement of inferior vena cava diameters by emergency department nurses.

    PubMed

    De Lorenzo, Robert A; Holbrook-Emmons, Victoria L

    2014-01-01

    Sonographic measurement of the inferior vena cava (IVC) diameter is a potentially important noninvasive estimate of fluid status. We researched whether nurses without prior ultrasonography experience could accurately obtain vena cava diameter measurements on models and subjects in comparison with those obtained by an expert sonographer. The design was a prospective educational study using a pre- and posttest of knowledge and a comparison of imaging performance between a subject and an expert sonographer. The setting was an urban teaching medical center with emergency nurses and a convenience sample of volunteer patients selected from the emergency department (ED). Nurses completed a written survey and a pretest to document prior training and experience in ultrasonography and assess baseline knowledge. A structured training program (3.5 hr in length) was provided over three sessions. Training consisted of didactic presentations, practice on phantoms (manikin models designed to provide the sonographic image of the human body when scanned by a trainee) and classmates, and one volunteer patient in the ED. Each nurse then measured IVC diameters on three different volunteer patients in transverse and longitudinal orientations using frozen images. An expert sonographer, blinded to subject results, performed the same examination. Correlations were determined, and a posttraining written examination was completed and results compared with the pretest using a pair-wise t test. Fourteen nurses, with a mean of 8 years' nursing experience (range = 2-18 years), participated. Nurse-expert R value correlation for the longitudinal orientation was 0.68 (95% confidence interval [CI] [0.35, 0.76]) and 0.59 (95% CI [0.47, 0.81]) for the transverse orientation. Posttest scores improved 8.2 percentage points (95% CI [4.0, 12.4]) from 83.3% to 91.5%. Following a brief training course, nurses with no prior sonography experience show moderately good correlation measuring the IVC diameter as compared with expert measurements, with better performance demonstrated in the longitudinal orientation.

  15. Cardiovascular System Sonographic Evaluation Algorithm: A New Sonographic Algorithm for Evaluation of the Fetal Cardiovascular System in the Second Trimester.

    PubMed

    De León-Luis, Juan; Bravo, Coral; Gámez, Francisco; Ortiz-Quintana, Luis

    2015-07-01

    To evaluate the reproducibility and feasibility of the new cardiovascular system sonographic evaluation algorithm for studying the extended fetal cardiovascular system, including the portal, thymic, and supra-aortic areas, in the second trimester of pregnancy (19-22 weeks). We performed a cross-sectional study of pregnant women with healthy fetuses (singleton and twin pregnancies) attending our center from March to August 2011. The extended fetal cardiovascular system was evaluated by following the new algorithm, a sequential acquisition of axial views comprising the following (caudal to cranial): I, portal sinus; II, ductus venosus; III, hepatic veins; IV, 4-chamber view; V, left ventricular outflow tract; VI, right ventricular outflow tract; VII, 3-vessel and trachea view; VIII, thy-box; and IX, subclavian arteries. Interobserver agreement on the feasibility and exploration time was estimated in a subgroup of patients. The feasibility and exploration time were determined for the main cohort. Maternal, fetal, and sonographic factors affecting both features were evaluated. Interobserver agreement was excellent for all views except view VIII; the difference in the mean exploration time between observers was 1.5 minutes (95% confidence interval, 0.7-2.1 minutes; P < .05). In 184 fetuses (mean gestational age ± SD, 20 ± 0.6 weeks), the feasibility of all views was close to 99% except view VIII (88.7%). The complete feasibility of the algorithm was 81.5%. The mean exploration time was 5.6 ± 4.2 minutes. Only the occiput anterior fetal position was associated with a lower frequency of visualization and a longer exploration time (P < .05). The cardiovascular system sonographic evaluation algorithm is a reproducible and feasible approach for exploration of the extended fetal cardiovascular system in a second-trimester scan. It can be used to explore these areas in normal and abnormal conditions and provides an integrated image of extended fetal cardiovascular anatomy. © 2015 by the American Institute of Ultrasound in Medicine.

  16. In Vivo High-Frequency, Contrast-Enhanced Ultrasonography of Uveal Melanoma in Mice: Imaging Features and Histopathologic Correlations

    PubMed Central

    Zhang, Qing; Yang, Hua; Kang, Shin J.; Wang, Yanggan; Wang, Geoffrey D.; Coulthard, Tonya

    2011-01-01

    Purpose. To evaluate the usefulness of in vivo imaging of uveal melanoma in mice using high-frequency contrast-enhanced ultrasound (HF-CE-US) with 2D or 3D modes and to correlate the sonographic findings with histopathologic characteristics. Methods. Fourteen 12-week-old C57BL6 mice were inoculated into their right eyes with aliquots of 5 × 105/2.5 μL B16LS9 melanoma cells and were randomly assigned to either of two groups. At 7 days after inoculation, tumor-bearing eyes in group 1 (n = 8) were imaged using HF-CE-US to determine the 2D tumor size and relative blood volume; eyes in group 2 (n = 6) were imaged by 3D microbubble contrast-enhanced ultrasound, and the tumor volume was determined. Histologic tumor burden was quantified in enucleated eyes by image processing software, and microvascular density was determined by counting von Willebrand factor-positive vascular channels. Ultrasound images were evaluated and compared with histopathologic findings. Results. Using HF-CE-US, melanomas were visualized as relatively hyperechoic regions. The intraobserver variability of sonographic measurements was 9.65% ± 7.89%, and the coefficient of variation for multiple measurements was 7.33% ± 5.71%. The correlation coefficient of sonographic volume or size and histologic area was 0.71 (P = 0.11) and 0.79 (P = 0.32). The relative blood volume within the tumor demonstrated sonographically correlated significantly with histologic tumor vascularity (r = 0.83; P < 0.001). Conclusions. There was a positive linear correlation between sonographic tumor measurements and histologic tumor burden in the mouse ocular melanoma model. Contrast-enhanced intensity corresponded with microvascular density and blood volume. HF-CE-US is a real-time, noninvasive, reliable method for in vivo evaluation of experimental intraocular melanoma tumor area and relative blood volume. PMID:21245408

  17. Single-polarization hollow-core square photonic bandgap waveguide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eguchi, Masashi, E-mail: megu@ieee.org; Tsuji, Yasuhide, E-mail: y-tsuji@mmm.muroran-it.ac.jp

    Materials with a periodic structure have photonic bandgaps (PBGs), in which light can not be guided within certain wavelength ranges; thus light can be confined within a low-index region by the bandgap effect. In this paper, rectangular-shaped hollow waveguides having waveguide-walls (claddings) using the PBG have been discussed. The design principle for HE modes of hollow-core rectangular PBG waveguides with a Bragg cladding consisting of alternating high- and low-index layers, based on a 1D periodic multilayer approximation for the Bragg cladding, is established and then a novel single-polarization hollow-core square PBG waveguide using the bandgap difference between two polarized wavesmore » is proposed. Our results demonstrated that a single-polarization guiding can be achieved by using the square Bragg cladding structure with different layer thickness ratios in the mutually orthogonal directions and the transmission loss of the guided mode in a designed hollow-core square PBG waveguide is numerically estimated to be 0.04 dB/cm.« less

  18. Curriculum Guide for Drafting Communication in Technology Education.

    ERIC Educational Resources Information Center

    Connecticut Industrial Technology Association.

    Consistent with the principles of the Connecticut Common Core of Learning, this competency-based curriculum guide for drafting provides a reference guide for educators to research and prepare for teaching the field of drafting communications. The guide contains 44 units in three levels. The introductory level covers the following topics:…

  19. Curriculum Guide for Electronics in Technology Education.

    ERIC Educational Resources Information Center

    Connecticut Industrial Technology Association.

    Consistent with the principles of the Connecticut Common Core of Learning, this competency-based curriculum guide for electronics provides a reference guide for educators to research and prepare for teaching the field of electronics. The guide contains 22 units that cover the following topics: theory of matter; safety; direct current; magnetism;…

  20. Diesel Equipment Department. Student Learning Guide.

    ERIC Educational Resources Information Center

    Palm Beach County Board of Public Instruction, West Palm Beach, FL.

    Eleven student learning guides are provided for the duty entitled "completing core curriculum" of the diesel equipment program. Each learning guide concerns one of the tasks that comprise the duty. Introductory materials for each guide include the purpose and performance and enabling objectives. For each enabling objective, these materials are…

  1. Diabetic mastopathy: a diagnostic challenge in breast sonography.

    PubMed

    Moschetta, Marco; Telegrafo, Michele; Triggiani, Vincenzo; Rella, Leonarda; Cornacchia, Ilaria; Serio, Gabriella; Ianora, Amato Antonio Stabile; Angelelli, Giuseppe

    2015-02-01

    Our purpose was to retrospectively evaluate the incidence and morphologic features of diabetic mastopathy in a group of patients with diabetes, searching for specific sonographic characteristics of diabetic mastopathy. One hundred twenty diabetic patients underwent breast clinical examination, mammography, and sonography. All detected breast lesions were confirmed histopathologically. Breast lesions were found in 11 of the 120 patients (9%), including two cases of invasive ductal carcinomas and nine cases of diabetic mastopathy. In seven of those nine cases (77%), diabetic mastopathy appeared as a hypoechoic solid mass with irregular margins, inhomogeneous echotexture, and marked posterior shadowing. In the other two cases (23%), it appeared as a mildly inhomogeneous, hypoechoic solid mass. Diabetic mastopathy is a diagnostic challenge and needs to be suspected in all patients with diabetes mellitus. Imaging features are nonspecific and highly susggestive on breast sonography in most cases. Core-needle biopsy confirmation remains mandatory for a definitive diagnosis. © 2015 Wiley Periodicals, Inc.

  2. Advances in MRI for the evaluation of carotid atherosclerosis

    PubMed Central

    Teng, Z; Patterson, A J; Lin, J-M; Young, V; Graves, M J; Gillard, J H

    2015-01-01

    Carotid artery atherosclerosis is an important source of mortality and morbidity in the Western world with significant socioeconomic implications. The quest for the early identification of the vulnerable carotid plaque is already in its third decade and traditional measures, such as the sonographic degree of stenosis, are not selective enough to distinguish those who would really benefit from a carotid endarterectomy. MRI of the carotid plaque enables the visualization of plaque composition and specific plaque components that have been linked to a higher risk of subsequent embolic events. Blood suppressed T1 and T2 weighted and proton density-weighted fast spin echo, gradient echo and time-of-flight sequences are typically used to quantify plaque components such as lipid-rich necrotic core, intraplaque haemorrhage, calcification and surface defects including erosion, disruption and ulceration. The purpose of this article is to review the most important recent advances in MRI technology to enable better diagnostic carotid imaging. PMID:25826233

  3. Scanning through the pain: ergonomic considerations for performing echocardiography of animals.

    PubMed

    Macdonald, Kristin; Scott, Patrick

    2013-03-01

    Work-related musculoskeletal disorders (MSD) are a common problem among sonographers, with prevalence in human sonographers of 80-90%. However, this problem appears to be largely neglected in the veterinary literature. Awareness of MSDs, ergonomic redesign, workplace management, and physical self-care are components to reducing the risk of developing MSDs. Work-place redesign and alterations in work flow management are discussed, and a template for a more ergonomically favorable echocardiogram table is provided. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Sonographic diagnosis of abscess following breast-conserving surgery with insertion of nonabsorbable mesh.

    PubMed

    Song, Sung Eun; Seo, Bo Kyoung; Son, Gil-Soo; Kim, Young-Sik

    2014-09-01

    Immediate mesh insertion has been recently used for breast reconstruction after breast-conserving surgery. We report a case of abscess formation following immediate nonabsorbable mesh insertion with breast-conserving surgery. In this article, we demonstrate multimodal breast imaging features and pathologic correlations of the case. In addition, we illustrate characteristic sonographic findings of nonabsorbable mesh fibers to differentiate them from a gossypiboma caused by a retained surgical sponge or tumor recurrence. © 2014 Wiley Periodicals, Inc.

  5. Child with acute lobar nephronia

    PubMed Central

    Vijayakumar, M.; Prahlad, N.; Nandhini, G.; Prasad, N.; Muralinath, S.

    2010-01-01

    A five-year-old girl child presented to us with a history of two weeks high grade fever treated outside with intensive antibiotic therapy for an ultrasound abdomen finding of hypoechoic lesion in the midpole of the left kidney. As fever and sonographic findings persisted, a CT abdomen was done, which showed features of lobar nephronia but reported as Wilm’s tumor. Child underwent open biopsy and the diagnosis of lobar nephronia was confirmed. Child was continued on antibiotics and fever and sonographic findings improved. PMID:21072159

  6. pH Testing. Youth Training Scheme. Core Exemplar Work Based Project.

    ERIC Educational Resources Information Center

    Further Education Staff Coll., Blagdon (England).

    This trainer's guide is intended to assist supervisors of work-based career training projects in teaching students how to sample and analyze soil to determine its pH value. The guide is one in a series of core curriculum modules that is intended for use in combination on- and off-the-job programs to familiarize youth with the skills, knowledge,…

  7. Core Curriculum in Preventing and Reducing School Violence and Vandalism. Course 3: School Climate. Participant Guide and Reference Notebook.

    ERIC Educational Resources Information Center

    Center for Human Services, Washington, DC.

    This guide, intended for participants in the third course of the National School Resource Network Core Curriculum, contains an activity/content summary for each module of the course, worksheets, and background materials. The purpose of the course is to introduce a conceptual overview and definition of "school climate" with the goal of effecting…

  8. Core Values | NREL

    Science.gov Websites

    Core Values Core Values NREL's core values are rooted in a safe and supportive work environment guide our everyday actions and efforts: Safe and supportive work environment Respect for the rights physical and social environment Integrity Maintain the highest standard of ethics, honesty, and integrity

  9. 77 FR 36014 - Initial Test Program of Emergency Core Cooling Systems for Boiling-Water Reactors

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-15

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0134] Initial Test Program of Emergency Core Cooling... for public comment draft regulatory guide (DG), DG-1277, ``Initial Test Program of Emergency Core... acceptable to implement with regard to initial testing features of emergency core cooling systems (ECCSs) for...

  10. Liquid-core photonic crystal fiber platform for raman scattering measurements of microliter analyte solutions

    NASA Astrophysics Data System (ADS)

    Han, Yun; Oo, Maung Khaing; Zhu, Yinian; Sukhishvili, Svetlana; Xiao, Limin; Demokan, M. Süleyman; Jin, Wei; Du, Henry

    2007-09-01

    We have explored the use of index-guiding liquid-core photonic crystal fiber (LC-PCF) as a platform for sensing and measurements of analyte solutions of minute volume by normal and surface-enhanced Raman scattering (SERS). The index-guiding LC-PCF was fabricated by selectively sealing via fusion splicing the cladding air channels of a hollow-core PCF (HC-PCF) while leaving the center core open at both ends of the fiber. The center core of the resultant fiber was subsequently filled with water-ethanol solution mixtures at various ethanol concentrations for normal Raman scattering measurements and with water-thiocynate solutions containing Ag nanoparticle aggregates for SERS detection of thiocynate at trace concentrations. The light-guiding nature in the solution phase inside the LC-PCF allows direct and strong light-field overlap with the solution phase over the entire length of the PCF (~30 cm). This detection scheme also dramatically reduces the contribution of silica to Raman spectral background, compared with the solid-core counterpart, thus its potential interference in spectral analysis. These features attribute to ready normal Raman measurements of water, ethanol, and water (99 vol.%)-ethanol (1 vol.%) solutions as well as sensitive and reproducible SERS detection of ~10 ppb thiocynate in water, all at a volume of ~0.1 μL.

  11. 76 FR 32878 - Draft Regulatory Guide: Issuance, Availability

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-07

    ...-0129] Draft Regulatory Guide: Issuance, Availability AGENCY: Nuclear Regulatory Commission. ACTION: Notice of Issuance and Availability of Draft Regulatory Guide, DG-1253, ``Preoperational Testing of Emergency Core Cooling Systems for Pressurized-Water Reactors''. FOR FURTHER INFORMATION CONTACT: Mekonen M...

  12. Sonographic investigation of anatomical specimens of infant hip joints.

    PubMed

    Falliner, Axel; Hahne, Hans-Jürgen; Hassenpflug, Joachim

    2002-07-01

    The anatomical foundations of infant hip sonography techniques are ill-defined. We investigated anatomical specimens of infant hip joints in a water bath, with Graf's and Terjesen's methods. Acetabular position was varied in defined increments, with respect to the ultrasound beam. The alpha angles and the femoral head coverage were measured. Plastic acetabular casts were sawn along the sonographic section planes, and the cut sections compared with the sonographic sections. For images to be obtained, which were analysable by the two methods, the ultrasound beam had to intersect with the acetabular inlet plane at defined angles. The acetabular notch had to be anteriorly rotated from the ultrasound beam plane by at least 20 degrees. Beam entry within a 50 degrees sector posterior to the perpendicular on the inlet plane gave analysable images. The alpha angles and femoral head coverage were much affected by coronal-plane transducer tilt. Caudad tilts were associated with lesser values, a fact that should be borne in mind in clinical ultrasound investigations.

  13. ["Dual Guidance"? - parallel combination of ultrasound-guidance and nerve stimulation - Contra].

    PubMed

    Maecken, Tim

    2015-07-01

    Sonography is a highly user-dependent technology. It presupposes a considerable degree of sonoanatomic and sonographic knowledge and requires good practical skills of the examiner. Sonography allows the identification of the puncture target, observes the needle feed and assesses the spread pattern of the local anesthetic in real time. Peripheral electrical nerve stimulation (PNS) cannot offer these advantages to the same degree, but may allow nerve localization under difficult sonographic conditions. The combination of the two locating techniques is complex in its practical implementation. Partially, the use of one location technique is made even more difficult by the combination with the second. PNS in parallel to sonography serves primarily as a warning technology in the case of an invisible cannula tip. It should not be construed as a compensation technique for the lack of sonographic skills or knowledge. However, PNS may be helpful in the sense of a bridging technology as long as the user is aware of its limitations. © Georg Thieme Verlag Stuttgart · New York.

  14. B-mode sonographic criteria for differential diagnosis of cervicofacial lymphadenopathy in cat-scratch disease and toxoplasmosis.

    PubMed

    Ridder, Gerd Jürgen; Boedeker, Carsten Christof; Lee, Tao-Kwang Kevin; Sander, Anna

    2003-04-01

    Our purpose was to evaluate different sonographic parameters of cervicofacial lymphadenopathy caused by cat-scratch disease (CSD) and toxoplasmosis. By use of high-resolution B-mode sonography a total of 552 lymph nodes in the head and neck were detected between January 1997 and December 2001. There were 71 patients (422 lymph nodes) with CSD and 19 patients (130 lymph nodes) with toxoplasmosis. Sonographic variables, including 20 sonomorphologic features along with age and gender, were analyzed with multivariate logistic regression. Heterogenous lymph nodes were more often found in CSD (p =.003), and nonsharp nodal borders showed a significant association with CSD (p =.0005). Multivariate analysis identified sharpness of borders (p =.0001), S/L ratio (p =.0006), and type of lymphadenopathy (acute, abscessed, chronic) (p =.0006) as most significant for differentiating between CSD and toxoplasmosis. These results provide significant and useful criteria for ultrasonographic differentiation between CSD and toxoplasmosis. Copyright 2003 Wiley Periodicals, Inc.

  15. Botulinum toxin type A injection into the gastrocnemius muscle for spastic equinus in adults with stroke: a randomized controlled trial comparing manual needle placement, electrical stimulation and ultrasonography-guided injection techniques.

    PubMed

    Picelli, Alessandro; Tamburin, Stefano; Bonetti, Paola; Fontana, Carla; Barausse, Martina; Dambruoso, Francesca; Gajofatto, Francesca; Santilli, Valter; Smania, Nicola

    2012-11-01

    The aim of this study was to compare the clinical outcomes of manual needle placement, electrical stimulation, and ultrasonography-guided techniques for botulinum toxin injection into the gastrocnemius of adults with spastic equinus after stroke. After randomization into three groups, each patient received the same dose of botulinum toxin type A into the lateral and medial head of the gastrocnemius muscle (OnabotulinumtoxinA, 100U per head) of the affected leg. The manual needle placement group (n = 15) underwent injections using anatomic landmarks and palpation; the electrical stimulation group (n = 15) received injections with electrical stimulation guidance; and the ultrasonography group (n = 17) was injected under sonographic guidance. The modified Ashworth scale, the Tardieu scale, and the ankle passive range of motion were measured at baseline and 1 mo after injection. Nonparametric statistical analysis was used. One month after injection, the modified Ashworth scale improved better in the ultrasonography group than in the manual needle placement group (P = 0.008). The ankle passive range of motion improved better in the ultrasonography group than in the electrical stimulation (P = 0.004) and manual needle placement (P < 0.001) groups. No difference was found between groups for the Tardieu scale. Ultrasonography-guided injection technique could improve the clinical outcome of botulinum toxin injections into the gastrocnemius of adults with spastic equinus.

  16. Integrated simulation of magnetic-field-assist fast ignition laser fusion

    NASA Astrophysics Data System (ADS)

    Johzaki, T.; Nagatomo, H.; Sunahara, A.; Sentoku, Y.; Sakagami, H.; Hata, M.; Taguchi, T.; Mima, K.; Kai, Y.; Ajimi, D.; Isoda, T.; Endo, T.; Yogo, A.; Arikawa, Y.; Fujioka, S.; Shiraga, H.; Azechi, H.

    2017-01-01

    To enhance the core heating efficiency in fast ignition laser fusion, the concept of relativistic electron beam guiding by external magnetic fields was evaluated by integrated simulations for FIREX class targets. For the cone-attached shell target case, the core heating performance deteriorates by applying magnetic fields since the core is considerably deformed and most of the fast electrons are reflected due to the magnetic mirror formed through the implosion. On the other hand, in the case of a cone-attached solid ball target, the implosion is more stable under the kilo-tesla-class magnetic field. In addition, feasible magnetic field configuration is formed through the implosion. As a result, the core heating efficiency doubles by magnetic guiding. The dependence of core heating properties on the heating pulse shot timing was also investigated for the solid ball target.

  17. Real-time video streaming of sonographic clips using domestic internet networks and free videoconferencing software.

    PubMed

    Liteplo, Andrew S; Noble, Vicki E; Attwood, Ben H C

    2011-11-01

    As the use of point-of-care sonography spreads, so too does the need for remote expert over-reading via telesonogrpahy. We sought to assess the feasibility of using familiar, widespread, and cost-effective existent technology to allow remote over-reading of sonograms in real time and to compare 4 different methods of transmission and communication for both the feasibility of transmission and image quality. Sonographic video clips were transmitted using 2 different connections (WiFi and 3G) and via 2 different videoconferencing modalities (iChat [Apple Inc, Cupertino, CA] and Skype [Skype Software Sàrl, Luxembourg]), for a total of 4 different permutations. The clips were received at a remote location and recorded and then scored by expert reviewers for image quality, resolution, and detail. Wireless transmission of sonographic clips was feasible in all cases when WiFi was used and when Skype was used over a 3G connection. Images transmitted via a WiFi connection were statistically superior to those transmitted via 3G in all parameters of quality (average P = .031), and those sent by iChat were superior to those sent by Skype but not statistically so (average P = .057). Wireless transmission of sonographic video clips using inexpensive hardware, free videoconferencing software, and domestic Internet networks is feasible with retention of image quality sufficient for interpretation. WiFi transmission results in greater image quality than transmission by a 3G network.

  18. Sonographic Findings of Chondral Avulsion Fractures of the Lateral Ankle Ligaments in Children.

    PubMed

    Maeda, Manabu; Maeda, Nana; Takaoka, Takanori; Tanaka, Yasuhito

    2017-02-01

    In this series, we aimed to describe the sonographic findings of chondral avulsion fractures that develop concomitant with lateral ankle ligament injury in children. We performed stress sonography during a manual anterior drawer stress procedure of the ankle in 9 skeletally immature patients who had recently had a lateral ankle sprain. Echo videos were obtained through the course of treatment, and all videos were reviewed. We elucidated the common features of chondral avulsion fractures of the lateral ankle ligaments in the children. The features of avulsion fractures on conventional sonography included absence of a fracture with hyperechoic spots (sonographic occult fracture type), cortical discontinuity with hyperechoic spots (cortical disruption fracture type), fracture line in the cortical bone (double-line fracture type), and a step-off deformity of the cortical bone with cartilage (displaced fracture type). In contrast, the features of chondral fractures on stress sonography included abnormal motion of the chondral lesions and mobility/fluidity of hyperechoic spots along the chondral fracture site. The presence of hyperechoic spots around the chondral lesion is an important sonographic sign for diagnosing chondral fractures concomitant with ankle lateral ligament injury. Hence, we believe that stress sonography should be considered for the detection of chondral fractures concomitant with radiographically negative ankle lateral ligament injuries in skeletally immature patients with lateral ankle pain and ankle sprains, if hyperechoic spots are present in the cartilage of the distal fibula. © 2017 by the American Institute of Ultrasound in Medicine.

  19. The efficiency of sonography in diagnosing volvulus in neonates with suspected intestinal malrotation

    PubMed Central

    Zhang, Wenhua; Sun, Hongjun; Luo, Fangqiong

    2017-01-01

    Abstract This study is to prospectively evaluate the efficiency of sonography for volvulus diagnosis in neonates with clinically suspected intestinal malrotation. A total of 83 patients with suspected intestinal malrotation who underwent detailed abdominal sonography and upper gastrointestinal contrast study were included. Malrotation was characterized by inversion of the superior mesenteric artery (SMA) and superior mesenteric vein (SMV) in sonographic examination. The “whirlpool sign” of Color Doppler Sonography was recognized as a characteristic for malrotation with volvulus. The degrees of rotation of the SMV winding around SMA were also detected by sonography. Surgery was performed in patients with sonography diagnosed malrotation. A total of 39 patients were sonographically diagnosed as malrotation which was subsequently confirmed by surgery. The sensitivity and positive predictive value of the sonographic diagnosis were both 100% (39/39). The sensitivity, specificity and accuracy of “whirlpool sign” for the detection of midgut volvulus were 95.2% (20/21), 88.9% (16/18), and 92.3% (36/39), respectively. Greater degrees of rotation (equal or greater than 720°) showed higher risk (odds ratio, 5.0; P < .01) for intestinal necrosis occurrence. Sonography is more accurate in diagnosing suspected malrotation than upper gastrointestinal contrast study. Specific sonographic “whirlpool sign” related to volvulus may be used as a potential indicator for intestinal necrosis. In addition, sonography can exclude malrotation and may help the diagnosis of other diseases, such as annular pancreas and duodenal atresia. PMID:29049228

  20. The efficiency of sonography in diagnosing volvulus in neonates with suspected intestinal malrotation.

    PubMed

    Zhang, Wenhua; Sun, Hongjun; Luo, Fangqiong

    2017-10-01

    This study is to prospectively evaluate the efficiency of sonography for volvulus diagnosis in neonates with clinically suspected intestinal malrotation.A total of 83 patients with suspected intestinal malrotation who underwent detailed abdominal sonography and upper gastrointestinal contrast study were included. Malrotation was characterized by inversion of the superior mesenteric artery (SMA) and superior mesenteric vein (SMV) in sonographic examination. The "whirlpool sign" of Color Doppler Sonography was recognized as a characteristic for malrotation with volvulus. The degrees of rotation of the SMV winding around SMA were also detected by sonography. Surgery was performed in patients with sonography diagnosed malrotation.A total of 39 patients were sonographically diagnosed as malrotation which was subsequently confirmed by surgery. The sensitivity and positive predictive value of the sonographic diagnosis were both 100% (39/39). The sensitivity, specificity and accuracy of "whirlpool sign" for the detection of midgut volvulus were 95.2% (20/21), 88.9% (16/18), and 92.3% (36/39), respectively. Greater degrees of rotation (equal or greater than 720°) showed higher risk (odds ratio, 5.0; P < .01) for intestinal necrosis occurrence.Sonography is more accurate in diagnosing suspected malrotation than upper gastrointestinal contrast study. Specific sonographic "whirlpool sign" related to volvulus may be used as a potential indicator for intestinal necrosis. In addition, sonography can exclude malrotation and may help the diagnosis of other diseases, such as annular pancreas and duodenal atresia.

  1. Sonographic Features of Cervical Lymph Nodes in Patients With Hashimoto Thyroiditis and the Impacts From the Levothyroxine With Prednisone Therapy.

    PubMed

    Lyu, Guo-Rong; Zheng, Wei-Kun; Lin, Wan-Ling; Zheng, Li-Ping; Guo, Hai-Xin; Li, Li-Ya

    2017-11-06

    This study aimed to evaluate the ultrasonographic pattern of cervical lymph nodes (CLNs) and whether levothyroxine with prednisone therapy is effective for lymphadenopathy in patients with Hashimoto thyroiditis (HT). This retrospective study was looking at patients with confirmed diagnosis of HT who underwent comprehensive neck ultrasound examination. We reviewed sonographic findings in 127 patients with HT, 234 euthyroid patients with goiter, and 122 healthy subjects. In addition, 30 untreated HT patients with cervical lymphadenopathy were recruited for the levothyroxine with prednisone therapy. We rescanned the patients 9 months after treatment with levothyroxine and prednisone. Patients with HT had a higher rate of CLN detection on ultrasound than euthyroid patients with goiter and healthy subjects at cervical levels III, IV, and VI (P < 0.01). In addition, patients with HT had a higher rate of detection of CLNs with abnormal sonographic features than the other 2 groups, most notably at cervical levels III, IV, and VI (P < 0.01). After the treatment, the mean thyroid volume, thyroid nodule volume, CLN volume, symptom score, and cosmetic grade of 30 HT patients were remarkably decreased (P < 0.01 or P < 0.001). Hashimoto thyroiditis seems to be associated with an increased rate of detection of CLNs with abnormal sonographic features, particularly at cervical levels III, IV, and VI. Therapy with levothyroxine with prednisone is effective for cervical lymphadenopathy in patients with HT.

  2. Focused physician-performed echocardiography in sports medicine: a potential screening tool for detecting aortic root dilatation in athletes.

    PubMed

    Yim, Eugene S; Kao, Daniel; Gillis, Edward F; Basilico, Frederick C; Corrado, Gianmichael D

    2013-12-01

    The purpose of this study was to investigate whether sports medicine physicians can obtain accurate measurements of the aortic root in young athletes. Twenty male collegiate athletes, aged 18 to 21 years, were prospectively enrolled. Focused echocardiography was performed by a board-certified sports medicine physician and a medical student, followed by comprehensive echocardiography within 2 weeks by a cardiac sonographer. A left parasternal long-axis view was acquired to measure the aortic root diameter at the sinuses of Valsalva. Intraclass correlation coefficients (ICCs) were used to assess inter-rater reliability compared to a reference standard and intra-rater reliability of repeated measurements obtained by the sports medicine physician and medical student. The ICCs between the sports medicine physician and cardiac sonographer and between the medical student and cardiac sonographer were strong: 0.80 and 0.76, respectively. Across all 3 readers, the ICC was 0.89, indicating strong inter-rater reliability and concordance. The ICC for the 2 measurements taken by the sports medicine physician for each athlete was 0.75, indicating strong intra-rater reliability. The medical student had moderate intra-rater reliability, with an ICC of 0.59. Sports medicine physicians are able to obtain measurements of the aortic root by focused echocardiography that are consistent with those obtained by a cardiac sonographer. Focused physician-performed echocardiography may serve as a promising technique for detecting aortic root dilatation and may contribute in this manner to preparticipation cardiovascular screening for athletes.

  3. Correlation between clinical fetal head station and sonographic angle of progression during the second stage of labor.

    PubMed

    Perlman, Sharon; Kivilevitch, Zvi; Moran, Orit; Katorza, Eldad; Kees, Salim; Achiron, Reuven; Gilboa, Yinon

    2017-08-04

    To investigate the correlation between the angle of progression and the clinical fetal head station (FHS) during the second stage of labor, and to build reference range. A prospective, observational study was conducted. Women carrying singleton term pregnancies were enrolled during the second stage of labor. FHS was assessed manually by a senior obstetrician, while the angle of progression (AOP) was assessed by transperineal ultrasound (TPU). Both examiners were blinded to each others results. The correlation between the sonographic AOP and the clinical FHS was analyzed. Seventy patients comprised the study group. Clinical FHS demonstrated an excellent correlation with the sonographic measurement of AOP (Pearson's Correlation 0.642, p < 0.001). This correlation was best described by a cubic regression according to the formula: 123.800 + 10.290 × FHS -2.889 * FHS +0.910, (r 2  = 0.423, p < .001). After aggregation of the mean AOP per FHS, the relative predicted centiles values and standard deviation were calculated. The mean Z score between measured and predicted values of the AOP for a given FHS was 0.007 (range -0.13 to +0.006). Our results demonstrate a significant correlation between the clinical FHS and the TPU measured AOP. These standardized sonographic values may serve the obstetrician as a reliable, objective auxiliary tool for the evaluation of the FHS during the second stage of labor.

  4. Comparison of Effectiveness in Differentiating Benign from Malignant Ovarian Masses between IOTA Simple Rules and Subjective Sonographic Assessment.

    PubMed

    Tongsong, Theera; Tinnangwattana, Dangcheewan; Vichak-Ururote, Linlada; Tontivuthikul, Paponrad; Charoenratana, Cholaros; Lerthiranwong, Thitikarn

    2016-01-01

    To compare diagnostic performance in differentiating benign from malignant ovarian masses between IOTA (the International Ovarian Tumor Analysis) simple rules and subjective sonographic assessment. Women scheduled for elective surgery because of ovarian masses were recruited into the study and underwent ultrasound examination within 24 hours of surgery to apply the IOTA simple rules by general gynecologists and to record video clips for subjective assessment by an experienced sonographer. The diagnostic performance of the IOTA rules and subjective assessment for differentiation between benign and malignant masses was compared. The gold standard diagnosis was pathological or operative findings. A total of 150 ovarian masses were covered, comprising 105 (70%) benign and 45 (30%) malignant. Of them, the IOTA simple rules could be applied in 119 (79.3%) and were inconclusive in 31 (20.7%) whereas subjective assessment could be applied in all cases (100%). The sensitivity and the specificity of the IOTA simple rules and subjective assessment were not significantly different, 82.9% vs 86.7% and 94.0% vs 94.3% respectively. The agreement of the two methods in prediction was high with a Kappa index of 0.835. Both techniques had a high diagnostic performance in differentiation between benign and malignant ovarian masses but the IOTA rules had a relatively high rate of inconclusive results. The IOTA rules can be used as an effective screening technique by general gynecologists but when the results are inconclusive they should consult experienced sonographers.

  5. The sensitivity of motor response to needle nerve stimulation during ultrasound guided interscalene catheter placement.

    PubMed

    Fredrickson, Michael J

    2008-01-01

    Neurostimulation during single shot interscalene block has a significant false negative motor response rate. Compared with tangential needle approaches for single shot block, interscalene catheter (ISC) placement commonly involves Tuohy needles inserted longitudinally to the brachial plexus. This study aimed to determine the sensitivity of neurostimulation during ultrasound-guided ISC needle placement, and the feasibility of an ultrasound-guided ISC needle endpoint. One hundred fifty-five consecutive nonstimulating ISCs were placed with the needle tip position confirmed by the sonographic spread of 5 mL dextrose 5%. Catheter advancement was then blind 2 to 3 cm past the needle tip. A 0.8 mA electrical stimulus at 2 Hz was applied throughout. When a satisfactory image was obtained, neurostimulation was ignored and the minimum motor response amplitude noted. If imaging was equivocal, a brief appropriate motor response at 0.8 mA was sought. A sustained response at <0.5 mA was only sought if imaging was suboptimal. Prior to surgery conducted under general anesthesia, 30 mL ropivacaine 0.5% was administered through the ISC. Catheter success was defined as a recovery room numerical rating pain score of

  6. Percutaneous imaging-guided interventions for acute biliary disorders in high surgical risk patients

    PubMed Central

    Donkol, Ragab Hani; Latif, Nahed Abdel; Moghazy, Khaled

    2010-01-01

    AIM: To evaluate the efficacy of percutaneous imaging-guided biliary interventions in the management of acute biliary disorders in high surgical risk patients. METHODS: One hundred and twenty two patients underwent 139 percutaneous imaging-guided biliary interventions during the period between January 2007 to December 2009. The patients included 73 women and 49 men with a mean age of 61 years (range 35-90 years). Fifty nine patients had acute biliary obstruction, 26 patients had acute biliary infection and 37 patients had abnormal collections. The procedures were performed under computed tomography (CT)- (73 patients), sonographic- (41 patients), and fluoroscopic-guidance (25 patients). Success rates and complications were determined. The χ2 test with Yates’ correction for continuity was applied to compare between these procedures. A P value < 0.05 was considered significant. RESULTS: The success rates for draining acute biliary obstruction under CT- , fluoroscopy- or ultrasound-guidance were 93.3%, 62.5% and 46.1%, respectively with significant P values (P = 0.026 and 0.002, respectively). In acute biliary infection, successful drainage was achieved in 22 patients (84.6%). The success rates in patients drained under ultrasound- and CT-guidance were 46.1% and 88.8%, respectively and drainage under CT-guidance was significantly higher (P = 0.0293). In 13 patients with bilomas, percutaneous drainage was successful in 11 patients (84.6%). Ten out of 12 cases with hepatic abscesses were drained with a success rate of 83.3%. In addition, the success rate of drainage in 12 cases with pancreatic pseudocysts was 83.3%. The reported complications were two deaths, four major and seven minor complications. CONCLUSION: Percutaneous imaging-guided biliary interventions help to promptly diagnose and effectively treat acute biliary disorders. They either cure the disorders or relieve sepsis and jaundice before operations. PMID:21160698

  7. Marketing Education Curriculum Guide.

    ERIC Educational Resources Information Center

    Michigan State Univ., East Lansing. Coll. of Agriculture and Natural Resources Education Inst.

    This curriculum guide is intended to provide a common core of competencies from which to design an effective secondary marketing education program. Introductory materials include a definition of marketing education, objectives, outline of instructional content, and questions and answers regarding the curriculum guide. These practical materials are…

  8. Primary angiosarcoma of the spleen--CT, MR, and sonographic characteristics: report of two cases.

    PubMed

    Vrachliotis, T G; Bennett, W F; Vaswani, K K; Niemann, T H; Bova, J G

    2000-01-01

    Primary angiosarcoma of the spleen is a rare entity, but it is the most common primary splenic malignancy. These tumors demonstrate an aggressive growth pattern and can be single or multiple. The diagnosis should be suspected in a patient who presents with splenomegaly but without evidence of lymphoma, malaria, leukemia, or portal hypertension. The tumor may also present with acute abdominal symptoms secondary to spontaneous splenic rupture. We describe two cases of primary angiosarcoma of the spleen with computed tomographic, magnetic resonance, and sonographic features.

  9. Supermodes in Coupled Multi-Core Waveguide Structures

    DTIC Science & Technology

    2016-04-01

    and therefore can be treated as linear polarization (LP) modes. In essence, the LP modes are scalar approximations of the vector mode fields and contain...field, including the discovery of optical discrete solitons , Bragg and vector solitons in fibers, nonlinear surface waves, and the discovery of self...increased for an isolated core, it can guide high-order modes. For optical fibers with low re- fractive index contrast, the vector modes are weakly guided

  10. AMIA Board white paper: definition of biomedical informatics and specification of core competencies for graduate education in the discipline

    PubMed Central

    Kulikowski, Casimir A; Shortliffe, Edward H; Currie, Leanne M; Elkin, Peter L; Hunter, Lawrence E; Johnson, Todd R; Kalet, Ira J; Lenert, Leslie A; Musen, Mark A; Ozbolt, Judy G; Smith, Jack W; Tarczy-Hornoch, Peter Z

    2012-01-01

    The AMIA biomedical informatics (BMI) core competencies have been designed to support and guide graduate education in BMI, the core scientific discipline underlying the breadth of the field's research, practice, and education. The core definition of BMI adopted by AMIA specifies that BMI is ‘the interdisciplinary field that studies and pursues the effective uses of biomedical data, information, and knowledge for scientific inquiry, problem solving and decision making, motivated by efforts to improve human health.’ Application areas range from bioinformatics to clinical and public health informatics and span the spectrum from the molecular to population levels of health and biomedicine. The shared core informatics competencies of BMI draw on the practical experience of many specific informatics sub-disciplines. The AMIA BMI analysis highlights the central shared set of competencies that should guide curriculum design and that graduate students should be expected to master. PMID:22683918

  11. Eigenvalue equation and core-mode cutoff of weakly guiding tapered fiber as three layer optical waveguide and used as biochemical sensor.

    PubMed

    Linslal, C L; Mohan, P M S; Halder, A; Gangopadhyay, T K

    2012-06-01

    The core-mode cutoff plays a major role in evanescent field absorption based sensors. A method has been proposed to calculate the core-mode cutoff by solving the eigenvalue equations of a weakly guiding three layer optical waveguide graphically. The variation of normalized waveguide parameter (V) is also calculated with different wavelengths at core-mode cutoff. At the first step, theoretical analysis of tapered fiber parameters has been performed for core-mode cutoff. The taper angle of an adiabatic tapered fiber is also analyzed using the length-scale criterion. Secondly, single-mode tapered fiber has been developed to make a precision sensor element suitable for chemical detection. Finally, the sensor element has been used to detect absorption peak of ethylenediamine. Results are presented in which an absorption peak at 1540 nm is observed.

  12. 45 CFR 162.1403 - Operating rules for health care claim status transaction.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... the following: (a) Except as specified in paragraph (b) of this section, the following CAQH CORE Phase... II CORE 250: Claim Status Rule, version 2.1.0, March 2011, and CORE v5010 Master Companion Guide, 00510, 1.2, March 2011. (Incorporated by reference in § 162.920). (2) Phase II CORE 270: Connectivity...

  13. Automated real-time needle-guide tracking for fast 3-T MR-guided transrectal prostate biopsy: a feasibility study.

    PubMed

    Zamecnik, Patrik; Schouten, Martijn G; Krafft, Axel J; Maier, Florian; Schlemmer, Heinz-Peter; Barentsz, Jelle O; Bock, Michael; Fütterer, Jurgen J

    2014-12-01

    To assess the feasibility of automatic needle-guide tracking by using a real-time phase-only cross correlation ( POCC phase-only cross correlation ) algorithm-based sequence for transrectal 3-T in-bore magnetic resonance (MR)-guided prostate biopsies. This study was approved by the ethics review board, and written informed consent was obtained from all patients. Eleven patients with a prostate-specific antigen level of at least 4 ng/mL (4 μg/L) and at least one transrectal ultrasonography-guided biopsy session with negative findings were enrolled. Regions suspicious for cancer were identified on 3-T multiparametric MR images. During a subsequent MR-guided biopsy, the regions suspicious for cancer were reidentified and targeted by using the POCC phase-only cross correlation -based tracking sequence. Besides testing a general technical feasibility of the biopsy procedure by using the POCC phase-only cross correlation -based tracking sequence, the procedure times were measured, and a pathologic analysis of the biopsy cores was performed. Thirty-eight core samples were obtained from 25 regions suspicious for cancer. It was technically feasible to perform the POCC phase-only cross correlation -based biopsies in all regions suspicious for cancer in each patient, with adequate biopsy samples obtained with each biopsy attempt. The median size of the region suspicious for cancer was 8 mm (range, 4-13 mm). In each region suspicious for cancer (median number per patient, two; range, 1-4), a median of one core sample per region was obtained (range, 1-3). The median time for guidance per target was 1.5 minutes (range, 0.7-5 minutes). Nineteen of 38 core biopsy samples contained cancer. This study shows that it is feasible to perform transrectal 3-T MR-guided biopsies by using a POCC phase-only cross correlation algorithm-based real-time tracking sequence. © RSNA, 2014.

  14. Atom guidance in the TE01 donut mode of a large-core hollow fiber

    NASA Astrophysics Data System (ADS)

    Pechkis, J. A.; Fatemi, F. K.

    2011-05-01

    We report on our progress towards low-light-level nonlinear optics experiments by optically guiding atoms in the TE01 donut mode of a hollow fiber. Atoms are transported over 12 cm from a ``source'' magneto-optical trap (MOT) through a 100- μm-diameter hollow fiber and are recaptured by a ``collection'' MOT situated directly below the fiber. For red-detuned guiding, we compare the guiding efficiency between the fundamental (Gaussian-like) mode and this donut mode, which has a larger guiding area but lower peak intensity. We also discuss our progress in transporting atoms in the dark core of this mode using blue-detuned light, which has more stringent constraints to atom guidance compared to red-detuned light. This work is supported by ONR.

  15. Early postoperative evaluation of groins after laparoscopic total extraperitoneal repair of inguinal hernias.

    PubMed

    Shpitz, Baruch; Kuriansky, Josef; Werener, Miriam; Osadchi, Alexandra; Tiomkin, Vitaly; Bugayev, Nikolay; Klein, Ehud

    2004-12-01

    Minimally invasive laparoscopic total extraperitoneal (LTEP) repair of bilateral and/or recurrent groin hernias has been popularized as one of the procedures of choice in the past decade. The early postoperative course is uneventful in most cases. A few patients, however, will develop temporary postoperative groin swelling. The aim of our study was to evaluate clinical and sonographic findings in the groin during the early postoperative period following LTEP. One hundred and five consecutive patients with primary bilateral (n = 90), recurrent unilateral (n = 12), and primary unilateral (n =3) groin hernias operated on during an 18-month period underwent clinical and sonographic examination two to three weeks after LTEP. On clinical examination, a localized groin swelling was found in 21 patients (20%). The most frequent sonographic findings were localized groin collections compatible with seroma or hematoma, found in 35 patients (33%). Hypoechoic diffuse tissue swelling around the mesh, lipomas, and residual hernias was found in four patients each (4%). None of the patients with hypoecoic mass had any clinical manifestations postoperatively. Extraperitoneal close suction drains were left for 8-12 hours in 46 patients. The average volume of fluid drained was 62 mL (range, 30-200 mL). There was no correlation between the use of suction drains and the frequency of fluid collections detected on sonography. Cord lipoma was detected postoperatively in four patients and was excised in one using an open anterior approach. Residual or recurrent hernia was detected postoperatively on sonography in four patients, but only one developed a symptomatic and clinically detectable hernia during eight months of follow-up. Overall, postoperative ultrasonographic findings following LTEP repair were found in 37% of patients. Clinical and sonographic findings such as localized fluid collections compatible with seroma or hematoma are common following LTEP. Postoperative suction drains did not reduce the frequency of sonographically detected collections. The clinical relevance of suspected postoperative hernia detected on sonography without clinical manifestations remains uncertain, and has to be determined on long-term follow-up.

  16. Cross-sectional associations between occupational factors and musculoskeletal pain in women teachers, nurses and sonographers.

    PubMed

    Arvidsson, Inger; Gremark Simonsen, Jenny; Dahlqvist, Camilla; Axmon, Anna; Karlson, Björn; Björk, Jonas; Nordander, Catarina

    2016-01-18

    It is usually assumed that musculoskeletal pain is associated with both the physical workload and the psychosocial work environment, as well as with personal and lifestyle factors. This study aims to ascertain the prevalence of musculoskeletal pain in women with varying or different occupational exposures, and to explore the associations between musculoskeletal pain and the occupational and personal factors. A questionnaire on physical, psychosocial and individual factors was answered by 1591 women in five occupational groups with contrasting occupational exposures (teachers, anaesthetic, theatre, and assistant nurses, and sonographers). The outcome measure was musculoskeletal pain (in a new model based on frequency and intensity of complaints the preceding year) from the neck, shoulders, hands, lower back and feet. Neck pain was equally frequent among teachers, assistant nurses and sonographers, and less frequent in anaesthetic and theatre nurses. The sonographers experienced the highest prevalence of shoulder pain, while the assistant nurses were the most affected in the wrists and hands, lower back, and feet. The teachers reported the highest scores in most of the psychosocial dimensions. The theatre nurses scored highest in strenuous work postures and movements (mechanical exposure index, MEI), and the assistant nurses in physical activity and lifting (physical exposure index, PHYI). Multivariable models in the total population showed that both the physical workload and the psychosocial work environment were associated with pain in all body regions, though different factors affected different regions. Pain in the neck, shoulders, hands and lower back was strongly associated with a high MEI and high job demands, while pain in the feet was associated with a high PHYI and a high BMI. A young age was associated with pain in the neck, and an older age was associated with pain in the hands and feet. Lack of time for personal recovery was associated with pain in the shoulders and lower back. The occupational groups were affected differently and need different protective measures. For the teachers, the psychosocial work environment should be improved. The surgical staff and sonographers require measures to mitigate lifting and constrained postures.

  17. Sonographic evaluation of tongue motions during upper airway stimulation for obstructive sleep apnea-a pilot study.

    PubMed

    Hofauer, Benedikt; Strohl, Kingman; Knopf, Andreas; Bas, Murat; Wirth, Markus; Stock, Konrad; Heiser, Clemens

    2017-03-01

    The objective was to evaluate the feasibility of sonographic evaluation of functional tongue motion as a tool to evaluate postoperative outcomes in human subjects using breathing-synchronized stimulation of the hypoglossal nerve-a novel therapy option for patients with obstructive sleep apnea (OSA). Sixteen patients with OSA (n = 16, age 60.4 ± 10.2, BMI 28.7 ± 2.4, AHI 35.0 ± 11.8) underwent sonographic evaluation of tongue motion after initiation of therapy with the Inspire II Upper Airway Stimulation system. Sonographic examination was performed in four different planes (A = floor of the mouth frontal, B = base of the tongue horizontal, C = floor of the mouth parallel to mandible, and D = floor of the mouth median sagittal) in an attempt to visualize tongue surface, tongue and hyoid motion, and the distance of protrusion. Identification of the tongue surface was achieved in all cases in planes B, C, and D and 81 % of patients in plane A. Tongue motion was evident on the right (implant) side in 63 % in plane A and 75 % in plane B. Distance of protrusion was measured in plane B at 1.04 cm (±0.51), in plane C at 1.08 cm (±0.47), and in plane D at 0.96 cm (±0.45). Hyoid protrusion was measured in plane C or D and was 0.57 cm (±0.39). Significant correlations among the three planes were observed, but there was no correlation to the reduction of apnea-hypopnea index. The results indicate feasibility of sonography to identify tongue and hyoid motions during upper airway stimulation. Useful sonographic planes and landmarks, which allow visualization of dynamic effects of upper airway stimulation, could be established. The evaluation of the tongue in a horizontal (B) and in a sagittal plane (D) appears to be superior to the other investigated planes. The approximate tongue protrusion needed to generate a significant reduction of AHI and ODI was 1 cm.

  18. Indications for pelvic sonography-Do patients and doctors agree?

    PubMed

    Rosen, M P; Mehta, T; Levine, D; Davis, R B

    2000-05-01

    Often, it seems that the patient history provided by the referring clinician on the sonography requisition form differs from that given by the patient during the sonographic examination. Because such a discrepancy in the history may delay the scan and disrupt the daily work flow while the referring clinician is contacted for clarification, we sought to document the incidence and cause of such discrepancies at our institution. During a 3-month period, all outpatients who were referred for a pelvic sonographic examination were asked to indicate their understanding of why the examination had been requested. The health care providers' reasons for requesting sonography were recorded using a computer order entry system. Each pair of responses (health care provider and patient) were classified as either concordant or discordant. Patient and physician characteristics were fit into a logistic regression model with concordance of history as the outcome variable. One hundred fifty-six (90%) of the 173 patients enrolled in our study indicated that their health care provider had discussed with them the reason for ordering the sonographic examination. The histories provided by the patient and health care provider were concordant in 134 (77%) of 173 cases. The histories provided by the patient and health care provider were more likely to be concordant if the patient's insurance was a managed care plan or if the patient had a college or graduate level education, had been cared for by the same health care provider for more than 2 years, or had been seen by a female health care provider. Concordance of history was not associated with a higher incidence of abnormal sonographic findings. It appears that health care providers, despite increased demands on their time, adequately discuss with their patients the reasons for ordering a pelvic sonographic examination. However, our study suggests that health care providers may need to spend additional time with patients whose education is limited and that male physicians may need to pay particular attention to their communication with female patients. Copyright 2000 John Wiley & Sons, Inc.

  19. Correlation of cytologic and histopathologic findings with perinodal echogenicity of abdominal lymph nodes in dogs and cats.

    PubMed

    Davé, Aditya C; Zekas, Lisa J; Auld, Danelle M

    2017-07-01

    Abdominal lymphadenopathy in dogs and cats is routinely investigated with ultrasound. As the determination between benign and neoplastic etiologies of lymphadenopathy affects patient management, specific sonographic characteristics associated with both benign and neoplastic lymph nodes have been suggested. However, a significant overlap between these characteristics exists, necessitating a cytologic or histopathologic diagnosis in most instances. The objectives of this retrospective, cross-sectional study were to evaluate whether echogenicity of perinodal fat could be a discriminator between benign and neoplastic abdominal lymphadenopathy and to assess if additional sonographic features associated with malignancy could be identified in lymph nodes with hyperechoic perinodal fat. Small animal patients (257 dogs and 117 cats) with sonographic evidence of abdominal lymphadenopathy and a cytological or histopathological diagnosis were evaluated for differences in the proportions of sonographic features between benign and neoplastic groups. Greater maximum long axis diameter (in dogs and cats) and a greater number of abnormal lymph nodes (in cats) were associated with malignancy in lymph nodes with hyperechoic perinodal fat. Canine lymph nodes with round cell neoplasia were significantly more likely to have hyperechoic perinodal fat. Lymph nodes affected with other neoplasia or with lymphadenitis were equally likely to have normal or hyperechoic perinodal fat. Reactive lymph nodes were significantly less likely to have hyperechoic perinodal fat in both species. These results suggest that though echogenicity of perinodal fat is a nonspecific finding, abdominal lymph nodes with hyperechoic perinodal fat are less likely to be reactive and sampling of these lymph nodes may be indicated. © 2017 American College of Veterinary Radiology.

  20. The use of ultrasound in the assessment of the glenoid labrum of the glenohumeral joint. Part I: Ultrasound anatomy and examination technique

    PubMed Central

    2012-01-01

    The glenohumeral joint is a spherical articulation with a remarkable range of motion in several planes and decreased stability. The maintenance of joint stability is influenced by the functioning of specific muscle groups in the shoulder region, a complex system of ligaments reinforcing the joint capsule, and the labrum which augments the glenoid fossa. Lesions of the aforementioned structures require accurate diagnosis prior to a decision for operative treatment. Ultrasound is one of the imaging methods that has been widely used in the assessment of various shoulder pathologies. In the author opinion, this imaging modality may also be applied for the evaluation of labral tears. Being attached along the glenoid rim, the labrum forms a collar deepening the glenoid fossa thus increasing area of its contact with the head of the humerus. To better describe the location of lesions, the glenoid labrum is usually divided into certain zones. Most of them may be visualized sonographically. The US examination of the posterior labrum can be performed during evaluation of the infraspinatus and teres minor muscles. The anterior labrum along with capsulolabral complex is seen at the glenoid edge under the subscapularis tendon. Sonographic examination of the inferior labrum is best performed using axillar approach. The superior labrum is only partially available for US examination. A crucial part of the sonographic assessment of the labrum is the dynamic examination during rotation of the upper extremity. The paper presents normal sonographic anatomy of the glenoid labrum and technique of the examination. PMID:26673515

  1. Evaluation of clinical and sonographic features in 55 children with tularemia.

    PubMed

    Oz, Fatma; Eksioglu, Ayse; Tanır, Gonul; Bayhan, Gulsum; Metin, Özge; Teke, Turkan Aydın

    2014-08-01

    The aim of this study was to determine the clinical characteristics and sonographic features of lymphadenopathy (LAP) and to evaluate the treatment modalities and treatment outcomes in children with tularemia. Demographic characteristics, ultrasonographic and physical examination findings, and treatment outcomes in 55 tularemia patients (24 male and 31 female) with a mean age of 10.8 ± 4.0 years were analyzed retrospectively. Lymph node necrosis was classified in three stages based on ultrasound findings-stage 1, cortical microabscesses; stage 2, cortical and medullar abscesses; stage 3, total necrosis of the lymph node. In total, 50 (90%) of the patients had oropharyngeal, four (8%) had glandular, and one (2%) had oculoglandular tularemia. The most common symptoms were sore throat (67%) and fever (64%). LAP was the most frequently (100%) observed sign. Abscess formation was noted in 36 (65%) patients, of which seven (19%) were sonographically classified as stage 1, 20 (55%) as stage 2, and nine (26%) as stage 3. There was a statistically significant correlation between delayed treatment and stage of abscess formation in lymph nodes (p<0.05). Treatment failure was observed in 24 (44%) patients. There was no significant correlation between treatment regimen and treatment failure (p>0.05). In all, nine (16%) of the patients did not respond to medical treatment, and surgical intervention was required. Tularemia should be considered in the differential diagnosis of children presenting with unexplained fever, sore throat, and cervical LAP in endemic areas. Sonographic findings may be useful in the evaluation and staging of this infection.

  2. Common Core Literacy Lesson Plans: Ready-to-Use Resources, K-5

    ERIC Educational Resources Information Center

    Davis, Lauren

    2013-01-01

    Schools nationwide are transitioning to the Common Core--our advice to you: Don't go it alone! Our new book, "Common Core Literacy Lesson Plans: Ready-to-Use Resources, K-5," shows you that teaching the Common Core State Standards in the elementary grades doesn't have to be intimidating! This easy-to-use guide provides model lesson plans for…

  3. Interdisciplinary Studies Program. Teacher's Guide: Part IV.

    ERIC Educational Resources Information Center

    Valencia Community Coll., Orlando, FL.

    This teacher's guide was developed for the last of four courses in Valencia Community College's Interdisciplinary Studies program, a 2-year core general education curriculum which chronologically examines the major developments in the evolution of human knowledge. The guide provides an introductory overview of the semester's content (i.e., the…

  4. Interdisciplinary Studies Program. Teacher's Guide: Part II.

    ERIC Educational Resources Information Center

    Valencia Community Coll., Orlando, FL.

    This teacher's guide was developed for the second of four courses in Valencia Community College's Interdisciplinary Studies Program, a 2-year core general education curriculum which chronologically examines the major developments in the evolution of human knowledge. The guide provides an introductory overview of the semester's topic (i.e., the…

  5. Interdisciplinary Studies Program. Teacher's Guide: Part III.

    ERIC Educational Resources Information Center

    Valencia Community Coll., Orlando, FL.

    This teacher's guide was developed for the third of four courses in Valencia Community College's Interdisciplinary Studies program, a 2-year core general education curriculum which chronologically examines the major developments in the evolution of human knowledge. The guide provides an introductory overview of the course's topic (i.e., Western…

  6. Interdisciplinary Studies Program. Teacher's Guide: Part I.

    ERIC Educational Resources Information Center

    Valencia Community Coll., Orlando, FL.

    This teacher's guide was developed for the first of four courses in Valencia Community College's Interdisciplinary Studies Program, a 2-year core general education curriculum which chronologically examines the major developments in the evolution of human knowledge. The guide provides an introductory overview of the semester's topic (i.e., the…

  7. Cadaver-based Necrotizing Fasciitis Model for Medical Training.

    PubMed

    Mohty, Kurt M; Cravens, Matthew G; Adamas-Rappaport, William J; Amini-Shervin, Bahareh; Irving, Steven C; Stea, Nicholas; Adhikari, Srikar; Amini, Richard

    2017-04-14

    Necrotizing fasciitis is a devastating infectious disease process that is characterized by extensive soft tissue necrosis along deep fascial planes, systemic toxicity, and high mortality. Ultrasound imaging is a rapid and non-invasive tool that can be used to help make the diagnosis of necrotizing fasciitis by identifying several distinctive sonographic findings. The purpose of this study is to describe the construction of a realistic diagnostic training model for necrotizing fasciitis using fresh frozen cadavers and common, affordable materials. Presently, fresh non-embalmed cadavers have been used at medical institutions for various educational sessions including cadaver-based ultrasound training sessions. Details for the preparation and construction of a necrotizing fasciitis cadaver model are presented here. This paper shows that the images obtained from the cadaver model closely imitate the ultrasound appearance of fluid and gas seen in actual clinical cases of necrotizing fasciitis. Therefore, it can be concluded that this cadaver-based model produces high-quality sonographic images that simulate those found in true cases of necrotizing fasciitis and is ideal for demonstrating the sonographic findings of necrotizing fasciitis.

  8. Vocational Education and Connecticut's Common Core of Learning.

    ERIC Educational Resources Information Center

    Connecticut State Dept. of Education, Hartford. Div. of Vocational, Technical, and Adult Education.

    The Connecticut State Board of Education policy known as the Common Core of Learning, outlines the skill, knowledge and attitudinal attainments expected of the state's secondary school graduates. This guide identifies the common core elements that can and should be reinforced through the vocational education curriculum. Information on the common…

  9. Diagnostic performance of power doppler and ultrasound contrast agents in early imaging-based diagnosis of organ-confined prostate cancer: Is it possible to spare cores with contrast-guided biopsy?

    PubMed

    Delgado Oliva, F; Arlandis Guzman, S; Bonillo García, M; Broseta Rico, E; Boronat Tormo, F

    2016-10-01

    To evaluate the diagnostic performance of gray scale transrectal ultrasound-B-mode US (BMUS), power Doppler (PDUS), and sonographic contrast (CEUS) in early imaging-based diagnosis of localized prostate cancer (PCa) and to compare the diagnostic profitability of randomized biopsy (RB), US-targeted prostate biopsy by means of PDUS and CEUS. A single-center, prospective, transversal, epidemiological study was conducted from January 2010 to January 2014. We consecutively included patients who an imaging study of the prostate with BMUS, PDUS, and CEUS was performed, followed by prostate biopsy due to clinical suspicion of prostate cancer (PSA 4-20ng/mL and/or rectal exam suggestive of malignancy). The diagnostic performance of BMUS, PDUS, and CEUS was determined by calculating the Sensitivity (S), Specificity (Sp), Predictive values (PV), and diagnostic odds ratio (OR) of the diagnosis tests and, for these variables, in the population general and based on their clinical stage according to rectal exam (cT1 and cT2). PCa detection rates determined by means of a randomized 10-core biopsy scheme were compared with detection rates of CEUS-targeted (SonoVue) 2-core biopsies. Of the initial 984 patients, US contrast SonoVue was administered to 179 (18.2%). The PCa detection rate by organ of BMUS/PDUS in the global population was 38% versus 43% in the subpopulation with CEUS. The mean age of the patients was 64.3±7.01years (95% CI, 63.75-64.70); mean total PSA was 8.9±3.61ng/mL (95% CI, 8.67-9.13) and the mean prostate volume was 56.2±29cc (95% CI, 54.2-58.1). The detection rate by organ of targeted biopsy with BMUS, PDUS, and CEUS were as follows: Global population (10.6, 8.2, 24.5%), stage cT1 (5.6, 4.2, 16.4%), and stage cT2 (32.4, 22.3, 43.5%). Comparing the detection rates of the CEUS-targeted biopsy and randomized biopsy, the following results were obtained: Global population (24.5% vs. 41.8%), stage cT1 (16% vs. 35%), and stage cT2 (43.5% vs. 66.6%), with a p value<0.05. Following the "core-by-core" analysis, the detection rates by core of CEUS-targeted biopsy versus randomized biopsy were: Global population (16% vs. 13%), stage cT1 (30.3% vs. 28%), and stage cT2 (48% vs. 37%), with a p value>0.05. The NNT for CEUS-targeted biopsy was 83.3. The low sensitivity, specificity, positive predictive and negative predictive values of gray scale-B-mode, PDUS and CEUS represent scant diagnostic performance of these variables in prostate cancer detection. Prostate cancer detection rates yielded by randomized biopsy were superior than the detection rate of targeted biopsy using B-mode, PDUS and CEUS; as a result, randomized biopsy versus CEUS-targeted biopsies cannot be excluded from biopsy strategy plans for the diagnosis of prostate cancer. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. Slipping rib syndrome: a place for sonography in the diagnosis of a frequently overlooked cause of abdominal or low thoracic pain.

    PubMed

    Meuwly, Jean-Yves; Wicky, Stephan; Schnyder, Pierre; Lepori, Domenico

    2002-03-01

    To describe the sonographic appearance of a poorly recognized cause of low thoracic or upper abdominal pain. Three sonographic descriptions of slipping rib syndrome are presented. The 3 patients had abnormal mobility of a cartilaginous rib, which could slip over an adjacent rib during abdominal muscle contraction. Slipping rib syndrome should be considered in patients with histories of upper abdominal or low thoracic pain of unknown origin. We suggest that high-resolution sonography of the costal margin should be added to abdominal sonography in cases of nonspecific abdominal pain.

  11. Sonographic diagnosis of hepatic erosion caused by umbilical catheterization.

    PubMed

    Schiavone, R; Narese, D; Ognibene, N; Rossi, E; Antonello, M; Basile, M; Di Maurizio, M; Defilippi, C

    2016-01-01

    The use of umbilical venous catheter (UVC) is common practice in neonatal units. The traumatic injury of the hepatic parenchyma is a rare complication. We present a case of a preterm newborn underwent ultrasound examination revealing a hyperechogenic focal lesion at the confluence of the hepatic veins This finding, according to patient's history, was suspected to be a traumatic injury of the liver parenchyma caused by umbilical catheterization. During sonographic follow-up this lesion gradually reduced until complete resolution. Finally, when focal hyperechogenic hepatic lesion is incidentally detected in newborn with history of UVC placement, the radiologists must consider the traumatic etiology.

  12. Upper internals arrangement for a pressurized water reactor

    DOEpatents

    Singleton, Norman R; Altman, David A; Yu, Ching; Rex, James A; Forsyth, David R

    2013-07-09

    In a pressurized water reactor with all of the in-core instrumentation gaining access to the core through the reactor head, each fuel assembly in which the instrumentation is introduced is aligned with an upper internals instrumentation guide-way. In the elevations above the upper internals upper support assembly, the instrumentation is protected and aligned by upper mounted instrumentation columns that are part of the instrumentation guide-way and extend from the upper support assembly towards the reactor head in hue with a corresponding head penetration. The upper mounted instrumentation columns are supported laterally at one end by an upper guide tube and at the other end by the upper support plate.

  13. The role of invasive sonography in the differential diagnosis and treatment of intraabdominal fluid collections.

    PubMed

    Regöly-Mérei, J; Ihász, M; Szeberin, Z; Záborszky, A

    Sixty-nine ultrasound-guided interventions (23 punctures and 46 drainages) were performed on 51 patients with the suspicion of intraabdominal abscess or another type of fluid collection in a prospective-controlled study. Of the procedures, 58.8% were carried out following surgery, while in 41.2% the indication were not related to prior surgical intervention. Repeated procedures were done in 10 patients. In the group of punctures the procedure was therapeutic in 3 cases and diagnostic in 16 patients. The drainage was technically successful in 92.7%. The drain was displaced or blocked in 27% (n = 10), but reinterventions were necessary in only 5 cases for this reason. The total number of redrainages was 18.9%. The percutaneous (pc) drainage was insufficient in 8 patients (21.6%), all these patients were operated on. 62.2% of the patients recovered after pc drainage, 13.5% following redrainage (total 75.5%). In 8.1% of the cases after pc drainage and in 5.4% after pc redrainage open surgery became necessary. There was only one complication due to the procedure. Seven patients (14.3%) died of the disease which indicated the procedure. There were no fatal outcomes on the account of the intervention. Ultrasound-guided puncture is a suitable method to indicate or contraindicate open surgery in the case of intraabdominal fluid collection. The diagnostic puncture may be followed by sonographically guided drainage or in selected cases by therapeutic puncture, but if the pc drainage is insufficient, open surgery should be performed in time.

  14. Common Core Literacy Lesson Plans: Ready-to-Use Resources, 9-12

    ERIC Educational Resources Information Center

    Davis, Lauren

    2013-01-01

    Schools nationwide are transitioning to the Common Core--our advice to you: Be prepared, but don't go it alone! Our new book, "Common Core Literacy Lesson Plans: Ready-to-Use Resources, 9-12," shows you that teaching the Common Core State Standards in high school doesn't have to be intimidating! This easy-to-use guide meets the particular needs of…

  15. Common Core Literacy Lesson Plans: Ready-to-Use Resources, 6-8

    ERIC Educational Resources Information Center

    Davis, Lauren

    2013-01-01

    Schools nationwide are transitioning to the Common Core--our advice to you: Don't go it alone! Our new book, "Common Core Literacy Lesson Plans: Ready-to-Use Resources, 6-8," shows you that teaching the Common Core State Standards in the middle grades doesn't have to be intimidating! This easy-to-use guide meets the particular needs of middle…

  16. Selective Guide to Literature on Agricultural Engineering. Engineering Literature Guides, Number 4.

    ERIC Educational Resources Information Center

    Cloud, Gayla Staples, Comp.

    Agricultural engineering overlaps many other disciplines. This document is a survey of information sources in agricultural engineering and is intended to identify those core resources which can help engineers and librarians to find information about the discipline. Sections include: (1) "Guides to the Literature"; (2) "Bibliographies"; (3)…

  17. A Kentucky Journey--African American Heritage. Teacher's Guide.

    ERIC Educational Resources Information Center

    Kentucky Historical Society, Frankfort.

    This guide to the core exhibit of the Kentucky History Center (Frankfort) focuses on African American history in the commonwealth of Kentucky. The guide extracts text from seven of the exhibit's chronological areas and lists environments, displays, and other exhibit features to help students understand some of the events that shaped the African…

  18. Office Education Curriculum Guide Series. [Core Document.

    ERIC Educational Resources Information Center

    Sullivan, Carol

    As one of a series of curriculum guides for office education programs in Texas, this guide contains units of instruction to assist in teaching the following objectives rated as necessary for the success of the program by experienced teachers across the state: (1) the essential elements common to all vocational programs and (2) the essential…

  19. Business Ownership and Management Core Curriculum. Teacher's Guide.

    ERIC Educational Resources Information Center

    National Business Education Association, Washington, DC.

    This curriculum guide accompanies a business ownership and management curriculum designed for the prevocational and exploratory grade levels (grades 7-9). An explanation of the need for such a curriculum, an overview of the curriculum, and instructions for using this guide are included in the three introductory sections. Major content consists of…

  20. Students' Understanding of Analogy after a Core (Chemical Observations, Representations, Experimentation) Learning Cycle, General Chemistry Experiment

    ERIC Educational Resources Information Center

    Avargil, Shirly; Bruce, Mitchell R. M.; Amar, Franc¸ois G.; Bruce, Alice E.

    2015-01-01

    Students' understanding about analogy was investigated after a CORE learning cycle general chemistry experiment. CORE (Chemical Observations, Representations, Experimentation) is a new three-phase learning cycle that involves (phase 1) guiding students through chemical observations while they consider a series of open-ended questions, (phase 2)…

  1. Explicit Instruction in Core Reading Programs

    ERIC Educational Resources Information Center

    Reutzel, D. Ray; Child, Angela; Jones, Cindy D.; Clark, Sarah K.

    2014-01-01

    The purpose of this study was to conduct a content analysis of the types and occurrences of explicit instructional moves recommended for teaching five essentials of effective reading instruction in grades 1, 3, and 5 core reading program teachers' editions in five widely marketed core reading programs. Guided practice was the most frequently…

  2. Common Core Units in Business Education: Grooming for Your Job Interview.

    ERIC Educational Resources Information Center

    Reddell, Lynda

    This secondary unit of instruction on grooming for job interviews is one of sixteen Common Core Units in Business Education (CCUBE). The units were designed for implementing the sixteen common core competencies identified in the California Business Education Program Guide for Office and Distributive Education. Each competency-based unit is…

  3. Towards real-time cardiovascular magnetic resonance guided transarterial CoreValve implantation: in vivo evaluation in swine

    PubMed Central

    2012-01-01

    Background Real-time cardiovascular magnetic resonance (rtCMR) is considered attractive for guiding TAVI. Owing to an unlimited scan plane orientation and an unsurpassed soft-tissue contrast with simultaneous device visualization, rtCMR is presumed to allow safe device navigation and to offer optimal orientation for precise axial positioning. We sought to evaluate the preclinical feasibility of rtCMR-guided transarterial aortic valve implatation (TAVI) using the nitinol-based Medtronic CoreValve bioprosthesis. Methods rtCMR-guided transfemoral (n = 2) and transsubclavian (n = 6) TAVI was performed in 8 swine using the original CoreValve prosthesis and a modified, CMR-compatible delivery catheter without ferromagnetic components. Results rtCMR using TrueFISP sequences provided reliable imaging guidance during TAVI, which was successful in 6 swine. One transfemoral attempt failed due to unsuccessful aortic arch passage and one pericardial tamponade with subsequent death occurred as a result of ventricular perforation by the device tip due to an operating error, this complication being detected without delay by rtCMR. rtCMR allowed for a detailed, simultaneous visualization of the delivery system with the mounted stent-valve and the surrounding anatomy, resulting in improved visualization during navigation through the vasculature, passage of the aortic valve, and during placement and deployment of the stent-valve. Post-interventional success could be confirmed using ECG-triggered time-resolved cine-TrueFISP and flow-sensitive phase-contrast sequences. Intended valve position was confirmed by ex-vivo histology. Conclusions Our study shows that rtCMR-guided TAVI using the commercial CoreValve prosthesis in conjunction with a modified delivery system is feasible in swine, allowing improved procedural guidance including immediate detection of complications and direct functional assessment with reduction of radiation and omission of contrast media. PMID:22453050

  4. Towards real-time cardiovascular magnetic resonance guided transarterial CoreValve implantation: in vivo evaluation in swine.

    PubMed

    Kahlert, Philipp; Parohl, Nina; Albert, Juliane; Schäfer, Lena; Reinhardt, Renate; Kaiser, Gernot M; McDougall, Ian; Decker, Brad; Plicht, Björn; Erbel, Raimund; Eggebrecht, Holger; Ladd, Mark E; Quick, Harald H

    2012-03-27

    Real-time cardiovascular magnetic resonance (rtCMR) is considered attractive for guiding TAVI. Owing to an unlimited scan plane orientation and an unsurpassed soft-tissue contrast with simultaneous device visualization, rtCMR is presumed to allow safe device navigation and to offer optimal orientation for precise axial positioning. We sought to evaluate the preclinical feasibility of rtCMR-guided transarterial aortic valve implatation (TAVI) using the nitinol-based Medtronic CoreValve bioprosthesis. rtCMR-guided transfemoral (n = 2) and transsubclavian (n = 6) TAVI was performed in 8 swine using the original CoreValve prosthesis and a modified, CMR-compatible delivery catheter without ferromagnetic components. rtCMR using TrueFISP sequences provided reliable imaging guidance during TAVI, which was successful in 6 swine. One transfemoral attempt failed due to unsuccessful aortic arch passage and one pericardial tamponade with subsequent death occurred as a result of ventricular perforation by the device tip due to an operating error, this complication being detected without delay by rtCMR. rtCMR allowed for a detailed, simultaneous visualization of the delivery system with the mounted stent-valve and the surrounding anatomy, resulting in improved visualization during navigation through the vasculature, passage of the aortic valve, and during placement and deployment of the stent-valve. Post-interventional success could be confirmed using ECG-triggered time-resolved cine-TrueFISP and flow-sensitive phase-contrast sequences. Intended valve position was confirmed by ex-vivo histology. Our study shows that rtCMR-guided TAVI using the commercial CoreValve prosthesis in conjunction with a modified delivery system is feasible in swine, allowing improved procedural guidance including immediate detection of complications and direct functional assessment with reduction of radiation and omission of contrast media.

  5. Single-molecule fluorescence measurements reveal the reaction mechanisms of the core RISC, composed of human Argonaute 2 and a guide RNA.

    PubMed

    Jo, Myung Hyun; Song, Ji-Joon; Hohng, Sungchul

    2015-12-01

    In eukaryotes, small RNAs play important roles in both gene regulation and resistance to viral infection. Argonaute proteins have been identified as a key component of the effector complexes of various RNA-silencing pathways, but the mechanistic roles of Argonaute proteins in these pathways are not clearly understood. To address this question, we performed single-molecule fluorescence experiments using an RNA-induced silencing complex (core-RISC) composed of a small RNA and human Argonaute 2. We found that target binding of core-RISC starts at the seed region of the guide RNA. After target binding, four distinct reactions followed: target cleavage, transient binding, stable binding, and Argonaute unloading. Target cleavage required extensive sequence complementarity and accelerated core-RISC dissociation for recycling. In contrast, the stable binding of core-RISC to target RNAs required seed-match only, suggesting a potential explanation for the seed-match rule of microRNA (miRNA) target selection.

  6. Fluorescence and Magnetic Resonance Dual-Modality Imaging-Guided Photothermal and Photodynamic Dual-Therapy with Magnetic Porphyrin-Metal Organic Framework Nanocomposites

    NASA Astrophysics Data System (ADS)

    Zhang, Hui; Li, Yu-Hao; Chen, Yang; Wang, Man-Man; Wang, Xue-Sheng; Yin, Xue-Bo

    2017-03-01

    Phototherapy shows some unique advantages in clinical application, such as remote controllability, improved selectivity, and low bio-toxicity, than chemotherapy. In order to improve the safety and therapeutic efficacy, imaging-guided therapy seems particularly important because it integrates visible information to speculate the distribution and metabolism of the probe. Here we prepare biocompatible core-shell nanocomposites for dual-modality imaging-guided photothermal and photodynamic dual-therapy by the in situ growth of porphyrin-metal organic framework (PMOF) on Fe3O4@C core. Fe3O4@C core was used as T2-weighted magnetic resonance (MR) imaging and photothermal therapy (PTT) agent. The optical properties of porphyrin were well remained in PMOF, and PMOF was therefore selected for photodynamic therapy (PDT) and fluorescence imaging. Fluorescence and MR dual-modality imaging-guided PTT and PDT dual-therapy was confirmed with tumour-bearing mice as model. The high tumour accumulation of Fe3O4@C@PMOF and controllable light excitation at the tumour site achieved efficient cancer therapy, but low toxicity was observed to the normal tissues. The results demonstrated that Fe3O4@C@PMOF was a promising dual-imaging guided PTT and PDT dual-therapy platform for tumour diagnosis and treatment with low cytotoxicity and negligible in vivo toxicity.

  7. Diagnostic Yield of Computed Tomography-Guided Coaxial Core Biopsy of Undetermined Masses in the Free Retroperitoneal Space: Single-Center Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stattaus, Joerg, E-mail: joerg.stattaus@uni-due.de; Kalkmann, Janine, E-mail: janine.kalkmann@uk-essen.de; Kuehl, Hilmar, E-mail: hilmar.kuehl@uni-due.d

    2008-09-15

    The purpose of this study was to evaluate the diagnostic yield of core biopsy in coaxial technique under guidance of computed tomography (CT) for retroperitoneal masses. We performed a retrospective analysis of CT-guided coaxial core biopsies of undetermined masses in the non-organ-bound retroperitoneal space in 49 patients. In 37 cases a 15-G guidance needle with a 16-G semiautomated core biopsy system, and in 12 cases a 16-G guidance needle with an 18-G biopsy system, was used. All biopsies were technically successful. A small hematoma was seen in one case, but no relevant complication occurred. With the coaxial technique, up tomore » 4 specimens were obtained from each lesion (mean, 2.8). Diagnostic accuracy in differentiation between malignant and benign diseases was 95.9%. A specific histological diagnosis could be established in 39 of 42 malignant lesions (92.9%). Correct subtyping of malignant lymphoma according to the WHO classification was possible in 87.0%. Benign lesions were correctly identified in seven cases, although a specific diagnosis could only be made in conjunction with clinical and radiological information. In conclusion, CT-guided coaxial core biopsy provides safe and accurate diagnosis of retroperitoneal masses. A specific histological diagnosis, which is essential for choosing the appropriate therapy, could be established in most cases of malignancy.« less

  8. Vascular Pattern Analysis on Microvascular Sonography for Differentiation of Pleomorphic Adenomas and Warthin Tumors of Salivary Glands.

    PubMed

    Ryoo, Inseon; Suh, Sangil; Lee, Young Hen; Seo, Hyung Suk; Seol, Hae Young; Woo, Jeong-Soo; Kim, Soo Chin

    2018-03-01

    Pleomorphic adenomas and Warthin tumors are the most common salivary gland tumors. It is important to differentiate between them because at least a partial parotidectomy is necessary for pleomorphic adenomas, whereas enucleation is sufficient for Warthin tumors. This study aimed to evaluate the usefulness of vascular pattern analysis using microvascular sonography to differentiate between the tumors. Sixty-two patients with pathologically proven pleomorphic adenomas (n = 38) and Warthin tumors (n = 24) were included. For all tumors, grayscale, power Doppler, and microvascular sonographic examinations were performed. Differences in vascular patterns (vascular distribution and internal vascularity) on power Doppler and microvascular sonography as well as grayscale sonographic features (size, shape, border, echogenicity, heterogeneity, and cystic change) between pleomorphic adenomas and Warthin tumors were evaluated. A comparison of diagnostic performances of grayscale sonography with power Doppler sonography and grayscale sonography with microvascular sonography was performed. The level of interobserver agreement between 2 reviewers in diagnosing tumors was evaluated. No grayscale sonographic features showed a significant difference between the tumors. Vascular distributions and internal vascularity on power Doppler sonography (P = .01 and .002) and microvascular sonography (both P < .001) were all significantly different. The diagnostic accuracy of grayscale sonography with microvascular sonography (79.0%) was higher than that of grayscale sonography with power Doppler sonography (72.6%). This difference was significant according to the McNemar test (P = .004). Interobserver agreement was excellent in diagnosing tumors on both grayscale sonography with power Doppler sonography (κ = 0.83) and grayscale sonography with microvascular sonography (κ = 0.94). Vascular pattern analysis using microvascular sonography with other sonographic features is helpful for differentiating between pleomorphic adenomas and Warthin tumors. © 2017 by the American Institute of Ultrasound in Medicine.

  9. New aids for the non-invasive prenatal diagnosis of achondroplasia: dysmorphic features, charts of fetal size and molecular confirmation using cell-free fetal DNA in maternal plasma.

    PubMed

    Chitty, L S; Griffin, D R; Meaney, C; Barrett, A; Khalil, A; Pajkrt, E; Cole, T J

    2011-03-01

    To improve the prenatal diagnosis of achondroplasia by constructing charts of fetal size, defining frequency of sonographic features and exploring the role of non-invasive molecular diagnosis based on cell-free fetal deoxyribonucleic acid (DNA) in maternal plasma. Data on fetuses with a confirmed diagnosis of achondroplasia were obtained from our databases, records reviewed, sonographic features and measurements determined and charts of fetal size constructed using the LMS (lambda-mu-sigma) method and compared with charts used in normal pregnancies. Cases referred to our regional genetics laboratory for molecular diagnosis using cell-free fetal DNA were identified and results reviewed. Twenty-six cases were scanned in our unit. Fetal size charts showed that femur length was usually on or below the 3(rd) centile by 25 weeks' gestation, and always below the 3(rd) by 30 weeks. Head circumference was above the 50(th) centile, increasing to above the 95(th) when compared with normal for the majority of fetuses. The abdominal circumference was also increased but to a lesser extent. Commonly reported sonographic features were bowing of the femora, frontal bossing, short fingers, a small chest and polyhydramnios. Analysis of cell-free fetal DNA in six pregnancies confirmed the presence of the c.1138G > A mutation in the FGRF3 gene in four cases with achondroplasia, but not the two subsequently found to be growth restricted. These data should improve the accuracy of diagnosis of achondroplasia based on sonographic findings, and have implications for targeted molecular confirmation that can reliably and safely be carried out using cell-free fetal DNA. Copyright © 2011 ISUOG. Published by John Wiley & Sons, Ltd.

  10. Initial Experience Using a Telerobotic Ultrasound System for Adult Abdominal Sonography.

    PubMed

    Adams, Scott J; Burbridge, Brent E; Badea, Andreea; Langford, Leanne; Vergara, Vincent; Bryce, Rhonda; Bustamante, Luis; Mendez, Ivar M; Babyn, Paul S

    2017-08-01

    The study sought to assess the feasibility of performing adult abdominal examinations using a telerobotic ultrasound system in which radiologists or sonographers can control fine movements of a transducer and all ultrasound settings from a remote location. Eighteen patients prospectively underwent a conventional sonography examination (using EPIQ 5 [Philips] or LOGIQ E9 [GE Healthcare]) followed by a telerobotic sonography examination (using the MELODY System [AdEchoTech] and SonixTablet [BK Ultrasound]) according to a standardized abdominal imaging protocol. For telerobotic examinations, patients were scanned remotely by a sonographer 2.75 km away. Conventional examinations were read independently from telerobotic examinations. Image quality and acceptability to patients and sonographers was assessed. Ninety-two percent of organs visualized on conventional examinations were sufficiently visualized on telerobotic examinations. Five pathological findings were identified on both telerobotic and conventional examinations, 3 findings were identified using only conventional sonography, and 2 findings were identified using only telerobotic sonography. A paired sample t test showed no significant difference between the 2 modalities in measurements of the liver, spleen, and diameter of the proximal aorta; however, telerobotic assessments overestimated distal aorta and common bile duct diameters and underestimated kidney lengths (P values < .05). All patients responded that they would be willing to have another telerobotic examination. A telerobotic ultrasound system is feasible for performing abdominal ultrasound examinations at a distant location with minimal training and setup requirements and a moderate learning curve. Telerobotic sonography (robotic telesonography) may open up the possibility of remote ultrasound clinics for communities that lack skilled sonographers and radiologists, thereby improving access to care. Copyright © 2016 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  11. [Performances and place of sonography in the diagnostic of endometriosis: CNGOF-HAS Endometriosis Guidelines].

    PubMed

    Philip, C-A; Dubernard, G

    2018-03-01

    Endometriosis is difficult to diagnose clinically. Transvaginal sonography (TVS) is a procedure that is known to be operator-dependent, which mean that published evidences has to be balanced with the level of the sonographer that produced the data. The objective of this publication was to assess the performances of the sonography in the diagnosis of endometriosis in order to establish the French national recommendations. We searched the MEDLINE database for publication from January 2000 to September 2017 using keywords associated with endometriosis and sonography. Eighty-four trial and reviews published in English or French were included. Ovarian endometrioma can usually be diagnosed by a non-expert sonographer, especially when its aspect is typical. In case of an ovarian cyst with atypical presentation, it is recommended to control the sonography by a referent or to perform an MRI. In menopaused women, any ovarian cyst should be considered as a cancer until proven otherwise. In the diagnosis of posterior deep invasive endometriosis (DIE), TVS with sensitivity and specificity of 96 and 99% respectively, seems at least equivalent if not superior to MRI. However, these performances are related to expert sonographers. To reach sufficient efficiency in posterior DIE, the estimated learning curve for a sonographer is 44 cases. When posterior DIE is suspected, we recommend proposing a TVS "performed by an expert" or a MRI "at least interpreted by an expert". In anterior DIE, TVS has a good specificity (100%), but its sensitivity is poor in the literature (64%). TVS is therefore not able to eliminate the diagnosis. However a renal ultrasound should be proposed each time a urinary endometriosis is confirmed, and should be considered whenever posterior DIE is diagnosed especially the lesion is superior to 3cm. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  12. Comparison of the effect of gonadotropin-releasing hormone agonist and dopamine receptor agonist on uterine myoma growth. Histologic, sonographic, and intra-operative changes.

    PubMed

    Sayyah-Melli, Manizheh; Tehrani-Gadim, Sepideh; Dastranj-Tabrizi, Ali; Gatrehsamani, Fatemeh; Morteza, Ghojazadeh; Ouladesahebmadarek, Elaheh; Farzadi, Laya; Kazemi-Shishvan, Maryamalsadat

    2009-08-01

    To investigate the effect of 2 medications; Diphereline and Cabergoline, on uterine leiomyoma growth, and its histologic, sonographic, and intra-operative changes. In an effort to treat large uterine leiomyoma in symptomatic patients in the Gynecology Clinics of the Alzahra Teaching Hospital of Tabriz University of Medical Sciences, Tabriz, Iran, from September 2007 to November 2008, 60 candidates randomized to receive Diphereline 3.75 mg, 4 times every 28 days (group I), and Cabergoline 0.5 mg, once a week for 6 weeks (group II), were included in this study. Clinical symptoms, feasibility of intra-operative dissection, intraoperative complications, sonographic, and pathologic characteristics of the tumor were evaluated. Thirteen patients from group I, and 10 patients from group II underwent surgery. There was a significant difference between the groups in the rate of lymphocyte infiltration (p=0.003), but not in other pathologic features. In both groups, the mitotic index was between 0-10. While there was no significant difference between the groups in the number (p=0.30), and volume of leiomyomas (p=0.65), however, changes in the uterine artery circulation was significant (p=0.001 [group I], p=0.026 [group II]). In addition, there was a significant difference between the groups for intra-operative hemorrhage and adhesion of leiomyomas to the uterine wall. This study found that Cabergoline is as effective as Diphereline in the shrinkage of myomas, accompanied by improvement in the sonographic, clinical, and intra-operative outcomes without any adverse pathological changes, and could be a good medical regimen as an adjunct to surgical management.

  13. Renal access in PNL under sonographic guidance: Do we really need to insert an open end ureteral catheter in dilated renal systems? A prospective randomized study.

    PubMed

    Eryildirim, Bilal; Tuncer, Murat; Camur, Emre; Ustun, Fatih; Tarhan, Fatih; Sarica, Kemal

    2017-10-03

    To evaluate the true necessity of open end ureteral catheter insertion in patients with moderate to severe pelvicalyceal system dilation treated with percutaneous nephrolithotomy (PNL) under sonographic guidance. 50 cases treated with PNL under sonographic guidance in prone position for solitary obstructing renal stones were evaluated. Patients were randomly divided into two groups; Group 1: Patients in whom a open end ureteral catheter was inserted prior to the procedure; Group 2: Patients receiving no catheter before PNL. In addition to the duration of the procedure as a whole and also all relevant stages as well, radiation exposure time, hospitalization period, mean nephrostomy tube duration, mean drop in Hb levels and all intra and postoperative complications have been evaluated. Mean size of the stones was 308.5 ± 133.2 mm2. Mean total duration of the PNL procedure in cases with open end ureteral catheter was significantly longer than the other cases (p < 0.001). Evaluation of the outcomes of the PNL procedures revealed no statistically significant difference between two groups regarding the stone-free rates (86% vs 84%). Additionally, there was no significant difference with respect to the duration of nephrostomy tube, hospitalization period and secondary procedures needed, complication rates as well as the post-operative Hb drop levels in both groups (p = 0.6830). Our results indicate that the placement of an open end ureteral catheter prior to a PNL procedure performed under sonographic access may not be indicated in selected cases presenting with solitary obstructing renal pelvic and/or calyceal stones.

  14. Measurement considerations on examiner-dependent factors in the ultrasound assessment of developmental dysplasia of the hip.

    PubMed

    Kolb, Alexander; Benca, Emir; Willegger, Madeleine; Puchner, Stephan E; Windhager, Reinhard; Chiari, Catharina

    2017-06-01

    The standardized sonographic hip screening according to Graf has increased reliability and comparability of measurements in the screening of developmental dysplasia of the hip (DDH). However, examiner dependent factors have been discussed to influence sonographic measurements. The objectives of this study were to examine the tolerance of the transducer positioning and to analyse the impact of transducer inclinations on Graf's hip grading system. Twenty-four hips in consecutive newborns were screened sonographically in combination with an optoelectronic motion capture system to trace transducer positions in space. Subsequently five defined inclinations of the transducer relative to Graf's neutral transducer position were analysed, giving a total of 144 sonographic images. We found a permissible transducer inclination in the axial plane of 8.8° to anterior and 8.1° to posterior. In the frontal plane we found a permissible inclination of 15.4° to caudal and 7.2° to cranial. The impact on the α-angle was significant for posterior-cranial (p < 0.001), cranial (p = 0.009), and caudal (p < 0.001) inclined transducer positions. The effect on the results according to Graf's grading system was significant for the caudal inclination of the transducer position (p < 0.001). Our findings show that the standardized plane defined by Graf's criteria allows notable inclinations of the transducer positions. Transducer inclinations show an impact on measurement results, which are clinically relevant. Those effects cannot be ruled out using Graf's ultrasound criteria alone. The examiner should pay attention to avoid transducer inclinations in the frontal plane and a combination of posterior and cranial inclination.

  15. Modification of a sonographic enthesitis score to differentiate between psoriatic arthritis and young healthy volunteers.

    PubMed

    Wervers, K; Vis, M; Rasappu, N; van der Ven, M; Tchetverikov, I; Kok, M R; Gerards, A H; Hazes, Jmw; Luime, J J

    2018-01-02

    We aimed to describe sonographic structural and inflammatory changes in entheses of patients with recently diagnosed psoriatic arthritis (PsA), patients with established PsA, and young healthy volunteers, and to investigate whether the MAdrid Sonographic Enthesitis Index (MASEI) enables us to distinguish these groups in an extreme comparison. New and established PsA patients and healthy volunteers (aged 20-30 years) were recruited. The triceps, quadriceps, patellar, Achilles and elbow extensor tendon insertion, and plantar fascia entheses were investigated sonographically for structural changes, erosions, calcifications, increased thickness, bursitis, and power Doppler (PD) signal according to the MASEI. The study included 25 new and 25 established PsA patients, and 25 healthy volunteers. Increased thickness and PD signal in knee entheses were common for patients and healthy volunteers, while changes at other locations predominantly occurred in patients only. PD was recoded (1, one spot; 1.5, two or three spots; 2, confluent signal; 3, severe confluent signal) and thickness of knee entheses excluded. This resulted in different modified MASEI scores between PsA patients and young healthy controls: median (interquartile range) modified MASEI of 13 (10-22.5) in new PsA, 13.5 (9.5-18) in established PsA, and 3 (1-8.5) in healthy volunteers (p = 0.002). Structural ultrasound changes and PD in entheses are common in both new and established PsA and healthy controls. MASEI score did not differentiate PsA patients from young healthy volunteers. After recoding of PD severity and excluding thickness of knee entheses, marked differences between PsA patients and healthy controls were observed.

  16. Reliability of sonographic assessment of tendinopathy in tennis elbow.

    PubMed

    Poltawski, Leon; Ali, Syed; Jayaram, Vijay; Watson, Tim

    2012-01-01

    To assess the reliability and compute the minimum detectable change using sonographic scales to quantify the extent of pathology and hyperaemia in the common extensor tendon in people with tennis elbow. The lateral elbows of 19 people with tennis elbow were assessed sonographically twice, 1-2 weeks apart. Greyscale and power Doppler images were recorded for subsequent rating of abnormalities. Tendon thickening, hypoechogenicity, fibrillar disruption and calcification were each rated on four-point scales, and scores were summed to provide an overall rating of structural abnormality; hyperaemia was scored on a five point scale. Inter-rater reliability was established using the intraclass correlation coefficient (ICC) to compare scores assigned independently to the same set of images by a radiologist and a physiotherapist with training in musculoskeletal imaging. Test-retest reliability was assessed by comparing scores assigned by the physiotherapist to images recorded at the two sessions. The minimum detectable change (MDC) was calculated from the test-retest reliability data. ICC values for inter-rater reliability ranged from 0.35 (95% CI: 0.05, 0.60) for fibrillar disruption to 0.77 (0.55, 0.88) for overall greyscale score, and 0.89 (0.79, 0.95) for hyperaemia. Test-retest reliability ranged from 0.70 (0.48, 0.84) for tendon thickening to 0.82 (0.66, 0.90) for overall greyscale score and 0.86 (0.73, 0.93) for calcification. The MDC for the greyscale total score was 2.0/12 and for the hyperaemia score was 1.1/5. The sonographic scoring system used in this study may be used reliably to quantify tendon abnormalities and change over time. A relatively inexperienced imager can conduct the assessment and use the rating scales reliably.

  17. Limited Abdominal Sonography for Evaluation of Children With Right Lower Quadrant Pain.

    PubMed

    Munden, Martha M; Wai, Shannon; DiStefano, Michael C; Zhang, Wei

    2017-01-01

    To determine whether a complete abdominal sonographic examination is necessary in the evaluation of children with right lower quadrant pain that is suspicious for appendicitis in the emergency department and whether performing a limited, more-focused study would miss clinically important disease. With Institutional Review Board approval, a retrospective study was performed of 704 patients, from ages 5-19 years, presenting to the emergency department with right lower quadrant pain that was suspicious for appendicitis who underwent a complete abdominal sonographic examination. Data were extracted from the complete abdominal sonographic examination to see whether abnormalities were noted in the pancreas, spleen, and left kidney. Patients' medical charts were reviewed to see whether any positive findings in these organs were clinically important. Of the 65 studies with a finding that would have been missed with a limited study, only 6 were found to be clinically important. Of those, 5 were managed medically and 1 surgically. The chance of missing a potentially important finding using a limited study with our group of patients was 65 of 704 patients (9.2%), with a 95% confidence interval of 7.2% to 11.7%. The chance of missing an abnormality that was clinically important was 6 of 704 patients (0.85%), with a 95% confidence interval of 0.35% to 1.94%. In children older than 5 years with abdominal pain that is suspicious for appendicitis, performing only a limited abdominal sonographic examination that excludes the pancreas, left kidney, and spleen will yield a miss rate for clinically important disease that is acceptably low to justify the savings of examination time. © 2016 by the American Institute of Ultrasound in Medicine.

  18. Remote Sonography in Routine Clinical Practice Between Two Isolated Medical Centers and the University Hospital Using a Robotic Arm: A 1-Year Study.

    PubMed

    Georgescu, Monica; Sacccomandi, Arnaud; Baudron, Bernard; Arbeille, Philippe L

    2016-04-01

    A robotic arm was developed by our laboratory for tele-operated echography on patients in locations isolated from a trained sonographer. The objective of the study was to evaluate, over a 1-year period, the use of the robotic arm for telesonography performed by a sonographer located at the University Hospital (Tours, France) on patients in two isolated medical centers 50 km away linked via the Internet. A nonsonographer operator (physician or paramedic) located the ultrasound probe attached to the robotic arm over the appropriate acoustic window for the organ of interest by rolling the whole robotic arm and mechanical support across the floor. The expert sonographer then telemanipulated the robotic arm via an Internet connection and adjusted the orientation of the probe until the most appropriate organ view for delivering a diagnosis was obtained. Three hundred telesonography examinations were performed within 1 year: 68 (22.7%) on abdominal organs, 20 (6.7%) on pelvic organs, 138 (46%) on supraaortic vessels (carotid artery), 33 (11%) on the thyroid, 30 (10%) on leg veins, and 11 (3.7%) on the kidney and urinary tract. Telesonography could not be achieved in 10 of the 300 cases due to poor image quality on obese patients or those presenting poor echogenicity. These cases were re-examined at the university hospital by a sonographer. The rate of telesonography exams over the 1-year period was 1.5 per day for the "general population" medical site and 1 per week for the "elderly patient" medical site. This study demonstrated that telesonography using a robotic arm can be routinely used for providing echographic diagnoses on patients isolated from imaging centers.

  19. 17-alpha-hydroxyprogesterone caproate versus vaginal progesterone suppository for the prevention of preterm birth in women with a sonographically short cervix: A randomized controlled trial.

    PubMed

    Pirjani, Reihaneh; Heidari, Reza; Rahimi-Foroushani, Abbas; Bayesh, Seyedehsara; Esmailzadeh, Arezoo

    2017-01-01

    The aim of this study was to compare 17-alpha-hydroxyprogesterone caproate (17OHP-C) with vaginal progesterone suppository for the prevention of preterm birth in women with a sonographically short cervix and to evaluate the changes of the cervical length (CL) over time. In this prospective randomized controlled trial, eligible patients were asymptomatic pregnant women with a sonographically short cervix. The participants in group 1 (n = 147) received vaginal progesterone suppositories at a dose of 400 mg daily and the women in group 2 (n = 150) received an i.m. dose of 250 mg 17OHP-C once a week. Transvaginal sonography was repeated every 3 weeks until 36 gestational weeks or the occurrence of preterm labor. A total of 304 singleton pregnant women between 16 and 24 gestational weeks with CL < 25 mm were enrolled in our study. The rates of preterm birth were 10.4% in the progesterone group and 14% in the 17OHP-C group: a difference that was not statistically significant (P = 0.416). Moreover, 264 participants underwent ultrasound examination five times and CL changes were studied for 15 weeks. The results showed that the CL changes over 15 weeks were statistically significant (P < 0.001), but the method of intervention (progesterone/17OHP-C) had no significant effect on CL change (P = 0.64). Our findings showed that vaginal progesterone and 17OHP-C had the same effect on the risk of preterm labor in asymptomatic women with a sonographically short cervix. We detected no significant difference between the effect of 17OHP-C and vaginal progesterone on CL changes over time. © 2016 Japan Society of Obstetrics and Gynecology.

  20. [The advantages of early midtrimester targeted fetal systematic organ screening for the detection of fetal anomalies--will a global change start in Israel?].

    PubMed

    Bronshtein, Moshe; Solt, Ido; Blumenfeld, Zeev

    2014-06-01

    Despite more than three decades of universal popularity of fetal sonography as an integral part of pregnancy evaluation, there is still no unequivocal agreement regarding the optimal dating of fetal sonographic screening and the type of ultrasound (transvaginal vs abdominal). TransvaginaL systematic sonography at 14-17 weeks for fetal organ screening. The evaluation of over 72.000 early (14-17 weeks) and late (18-24 weeks) fetal ultrasonographic systematic organ screenings revealed that 96% of the malformations are detectable in the early screening with an incidence of 1:50 gestations. Only 4% of the fetal anomalies are diagnosed later in pregnancy. Over 99% of the fetal cardiac anomalies are detectable in the early screening and most of them appear in low risk gestations. Therefore, we suggest a new platform of fetal sonographic evaluation and follow-up: The extensive systematic fetal organ screening should be performed by an expert sonographer who has been trained in the detection of fetal malformations, at 14-17 weeks gestation. This examination should also include fetal cardiac echography Three additional ultrasound examinations are suggested during pregnancy: the first, performed by the patient's obstetrician at 6-7 weeks for the exclusion of ectopic pregnancy, confirmation of fetal viability, dating, assessment of chorionicity in multiple gestations, and visualization of maternal adnexae. The other two, at 22-26 and 32-34 weeks, require less training and should be performed by an obstetrician who has been qualified in the sonographic detection of fetal anomalies. The advantages of early midtrimester targeted fetal systematic organ screening for the detection of fetal anomalies may dictate a global change.

  1. Sonographic findings of high-grade and non-high-grade ductal carcinoma in situ of the breast.

    PubMed

    Park, Ji-Sung; Park, Young-Mi; Kim, Eun-Kyung; Kim, Suk-Jung; Han, Sang-Suk; Lee, Sun-Joo; In, Hyun-Sin; Ryu, Ji-Hwa

    2010-12-01

    The purpose of this study was to differentiate between high-grade and non-high-grade ductal carcinoma in situ (DCIS) of the breast on sonography. From October 2003 to August 2009, 76 DCIS lesions in 73 women who underwent sonography and mammography were included in this study. Lesions were confirmed by mastectomy, breast-conserving surgery, or surgical biopsy. Images were analyzed by 2 radiologists with consensus and were correlated with histologic grades. Of the 76 lesions, 44 were classified as high--grade and 32 as non-high-grade DCIS. Fifty-seven lesions (75.0%) were identified on sonography, which revealed a mass in 30 cases, microcalcifications in 20, ductal changes in 4, and architectural distortion in 3. All cases with false-negative findings on sonography (n = 19) showed microcalcifications on mammography. On sonography, masses were more frequently found in non-high-grade (62.5%) than high-grade DCIS (22.7%; P < .01). No significant difference was seen in the sonographic features of masses between high-grade and non-high-grade DCIS. Microcalcifications were more common in high-grade (43.2%) than non-high-grade (3.1%) DCIS (P = .02). Most sonographically visible microcalcifications had associated findings such as ductal changes (n = 11), a mass (n = 7), or a hypoechoic area (n = 5). The detection rate of microcalcifications on sonography was higher in high-grade (62.9%) than non-high-grade DCIS (25.0%; P = .023). Microcalcifications with associated ductal changes (11 of 31 [35.5%]) were the most common sonographic findings in high-grade DCIS. An irregular hypoechoic mass with an indistinct and microlobulated margin (13 of 26 [50.0%]) was the most frequent finding in non-high-grade DCIS.

  2. Survey of the prevalence and methodology of quality assurance for B-mode ultrasound image quality among veterinary sonographers.

    PubMed

    Hoscheit, Larry P; Heng, Hock Gan; Lim, Chee Kin; Weng, Hsin-Yi

    2018-05-01

    Image quality in B-mode ultrasound is important as it reflects the diagnostic accuracy and diagnostic information provided during clinical scanning. Quality assurance programs for B-mode ultrasound systems/components are comprised of initial quality acceptance testing and subsequent regularly scheduled quality control testing. The importance of quality assurance programs for B-mode ultrasound image quality using ultrasound phantoms is well documented in the human medical and medical physics literature. The purpose of this prospective, cross-sectional, survey study was to determine the prevalence and methodology of quality acceptance testing and quality control testing of image quality for ultrasound system/components among veterinary sonographers. An online electronic survey was sent to 1497 members of veterinary imaging organizations: the American College of Veterinary Radiology, the Veterinary Ultrasound Society, and the European Association of Veterinary Diagnostic Imaging, and a total of 167 responses were received. The results showed that the percentages of veterinary sonographers performing quality acceptance testing and quality control testing are 42% (64/151; 95% confidence interval 34-52%) and 26% (40/156: 95% confidence interval 19-33%) respectively. Of the respondents who claimed to have quality acceptance testing or quality control testing of image quality in place for their ultrasound system/components, 0% have performed quality acceptance testing or quality control testing correctly (quality acceptance testing 95% confidence interval: 0-6%, quality control testing 95% confidence interval: 0-11%). Further education and guidelines are recommended for veterinary sonographers in the area of quality acceptance testing and quality control testing for B-mode ultrasound equipment/components. © 2018 American College of Veterinary Radiology.

  3. Aspiration biopsy of mammary analogue secretory carcinoma of accessory parotid gland: another diagnostic dilemma in matrix-containing tumors of the salivary glands.

    PubMed

    Levine, Pascale; Fried, Karen; Krevitt, Lane D; Wang, Beverly; Wenig, Bruce M

    2014-01-01

    Mammary analogue secretory carcinoma (MASC) is a newly described rare salivary gland tumor, which shares morphologic features with acinic cell carcinoma, low-grade cystadenocarcinoma, and secretory carcinoma of the breast. This is the first reported case of MASC of an accessory parotid gland detected by aspiration biopsy with radiologic and histologic correlation in a 34-year-old patient. Sonographically-guided aspiration biopsy showed cytologic features mimicking those of low-grade mucoepidermoid carcinoma, including sheets of bland epithelial cells, dissociated histiocytoid cells with intracytoplasmic mucinous material, and spindle cells lying in a web-like matrix. Histologic sections showed a circumscribed tumor with microcystic spaces lined by bland uniform epithelial cells and containing secretory material. The tumor cells expressed mammaglobin and BRST-2. The cytologic features, differential diagnosis, and pitfalls are discussed. The pathologic stage was pT1N0. The patient showed no evidence of disease at 1 year follow-up. Copyright © 2012 Wiley Periodicals, Inc.

  4. Endogenous Klebsiella endophthalmitis associated with liver abscess: first case report from iran.

    PubMed

    Dehghani, A R; Masjedi, A; Fazel, F; Ghanbari, H; Akhlaghi, M; Karbasi, N

    2011-01-07

    To report the first case of endogenous Klebsiella endophthalmitis associated with liver abscess in Iran. A 79-year-old man was referred to our hospital due to severe pain and visual loss in the left eye. On physical examination, conjunctival hyperemia, corneal edema, hypopyon and severe vitreous cellular reaction were identified in the left eye; however, yellowish conjunctival discoloration was more apparent in the right eye. Abdominal CT scan showed a right liver lobe abscess that was confirmed by sonographically guided percutaneous liver mass biopsy. Blood, vitreous and liver mass aspirate cultures revealed Klebsiella pneumoniae growth. The patient was thus diagnosed with endogenous Klebsiella endophthalmitis secondary to bacteremia associated with liver abscess. This report suggests that, rather than being confined to Taiwan, endogenous endophthalmitis secondary to a liver abscess due to K. pneumoniae may be a global problem. Therefore, physicians should be aware of the possibility of endophthalmitis whenever a patient with K. pneumoniae liver abscess complains of ocular symptoms.

  5. Calf Endurance and Achilles Tendon Structure in Classical Ballet Dancers.

    PubMed

    Zellers, Jennifer A; van Ostrand, Katrina; Silbernagel, Karin Grävare

    2017-06-15

    Optimal lower leg function is critical for ballet dancers to meet their occupational requirements. Achilles tendon injury is particularly detrimental to ballet dancers. While standardized measures have been validated and incorporated into clinical practice for use in people with Achilles tendon injury, normative ranges specific to the dancer population have not been described. The purpose of this pilot study was to observe the performance of pre-professional ballet students and professional ballet dancers on a well-established test battery for lower leg functional performance as well as ultra-sonographic evaluation of the structure of their Achilles tendons. The dancers in this study had significantly shorter Achilles tendons than non-dancers (p = 0.016). Dancers demonstrated significantly higher maximum heel-rise height on the heel-rise test for calf endurance (p < 0.001) but performed significantly less work than non-dancers (p = 0.014). The results of this study support the use of the heel-rise test as a tool for screening and to guide rehabilitation.

  6. Finite element simulation of core inspection in helicopter rotor blades using guided waves.

    PubMed

    Chakrapani, Sunil Kishore; Barnard, Daniel; Dayal, Vinay

    2015-09-01

    This paper extends the work presented earlier on inspection of helicopter rotor blades using guided Lamb modes by focusing on inspecting the spar-core bond. In particular, this research focuses on structures which employ high stiffness, high density core materials. Wave propagation in such structures deviate from the generic Lamb wave propagation in sandwich panels. To understand the various mode conversions, finite element models of a generalized helicopter rotor blade were created and subjected to transient analysis using a commercial finite element code; ANSYS. Numerical simulations showed that a Lamb wave excited in the spar section of the blade gets converted into Rayleigh wave which travels across the spar-core section and mode converts back into Lamb wave. Dispersion of Rayleigh waves in multi-layered half-space was also explored. Damage was modeled in the form of a notch in the core section to simulate a cracked core, and delamination was modeled between the spar and core material to simulate spar-core disbond. Mode conversions under these damaged conditions were examined numerically. The numerical models help in assessing the difficulty of using nondestructive evaluation for complex structures and also highlight the physics behind the mode conversions which occur at various discontinuities. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Alcohol Abuse Prevention: A Comprehensive Guide for Youth Organizations.

    ERIC Educational Resources Information Center

    Boys' Clubs of America, New York, NY.

    This guide, the culmination of a three year Project TEAM effort by the Boys' Clubs of America, describes numerous strategies for developing an alcohol abuse prevention program. The core of this guide consists of program models developed by the Boys' Club project at seven pilot sites. The models presented cover the following areas: peer leadership,…

  8. Guide to International Academic Standards for Athletics Eligibility for Students Entering Fall 2007

    ERIC Educational Resources Information Center

    Mills, Lisa; Nguyen, Binh; Auten, Lisa

    2007-01-01

    The "NCAA Guide to International Academic Standards for Athletics Eligibility" provides specific criteria to be used as a guide in reviewing the initial eligibility (graduation, core curriculum, grade-point average and ACT/SAT test scores) of students who have completed any portion of their secondary education in a non-United States…

  9. Image guided versus palpation guided core needle biopsy of palpable breast masses: a prospective study

    PubMed Central

    Hari, Smriti; Kumari, Swati; Srivastava, Anurag; Thulkar, Sanjay; Mathur, Sandeep; Veedu, Prasad Thotton

    2016-01-01

    Background & objectives: Biopsy of palpable breast masses can be performed manually by palpation guidance or under imaging guidance. Based on retrospective studies, image guided biopsy is considered more accurate than palpation guided breast biopsy; however, these techniques have not been compared prospectively. We conducted this prospective study to verify the superiority and determine the size of beneficial effect of image guided biopsy over palpation guided biopsy. Methods: Over a period of 18 months, 36 patients each with palpable breast masses were randomized into palpation guided and image guided breast biopsy arms. Ultrasound was used for image guidance in 33 patients and mammographic (stereotactic) guidance in three patients. All biopsies were performed using 14 gauge automated core biopsy needles. Inconclusive, suspicious or imaging-histologic discordant biopsies were repeated. Results: Malignancy was found in 30 of 36 women in palpation guided biopsy arm and 27 of 36 women in image guided biopsy arm. Palpation guided biopsy had sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of 46.7, 100, 100, 27.3 per cent, respectively, for diagnosing breast cancer. Nineteen of 36 women (52.8%) required repeat biopsy because of inadequate samples (7 of 19), suspicious findings (2 of 19) or imaging-histologic discordance (10 of 19). On repeat biopsy, malignancy was found in all cases of imaging-histologic discordance. Image guided biopsy had 96.3 per cent sensitivity and 100 per cent specificity. There was no case of inadequate sample or imaging-histologic discordance with image guided biopsy. Interpretation & conclusions: Our results showed that in palpable breast masses, image guided biopsy was superior to palpation guided biopsy in terms of sensitivity, false negative rate and repeat biopsy rates. PMID:27488003

  10. Axillary Sonography of the Shoulder: An Adjunctive Approach.

    PubMed

    Michelin, Paul; Legrand, Julie; Lee, Kenneth S; Leleup, Grégoire; Etancelin, Mathilde; Banse, Christopher; Dacher, Jean-Nicolas; Duparc, Fabrice

    2018-03-25

    Sonography of the shoulder is widely used to assess various disorders, including tendinous diseases of the rotator cuff and the long head of the biceps brachii muscle. The shoulder is commonly explored through anterior, superior, and posterior approaches, but the inferior axillary approach is rarely considered in the literature. However, this technique allows the direct visualization of relevant anatomic structures. The aim of this pictorial essay is, first, to technically describe this approach and the normal musculoskeletal sonographic anatomy of the region and, second, to present the sonographic findings of shoulder disorders that may be helpfully explored this technique. © 2018 by the American Institute of Ultrasound in Medicine.

  11. Fibromatosis of the breast mimicking an abscess: case report of unusual sonographic features.

    PubMed

    Lee, So Min; Lee, Ji Young; Lee, Byung Hoon; Kim, Su Young; Joo, Mee; Kim, Jae Il

    2015-01-01

    Fibromatosis of the breast, also known as a desmoid tumor, is extremely rare and most often appears as an aggressive lesion mimicking breast carcinoma. It lacks metastatic potential but can grow aggressively in a localized area. Ultrasonography often shows an irregular spiculated hypoechoic mass with posterior acoustic shadowing. We discuss a case of breast fibromatosis that presented as a painful palpable breast mass in a 32-year-old woman and mimicked an abscess in the sonogram. We found that this lesion displayed atypical sonographic features such as a heterogeneous echoic mass with an internal anechoic area. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Clinical, pathological and sonographic characteristics of unexpected gallbladder carcinoma

    PubMed Central

    Wang, Jin-Huan; Liu, Bo-Ji; Xu, Hui-Xiong; Sun, Li-Ping; Li, Dan-Dan; Guo, Le-Hang; Liu, Lin-Na; Xu, Xiao-Hong

    2015-01-01

    Objectives: To investigate the clinical, pathological, and sonographic characteristics of unexpected gallbladder carcinoma (UGC). Methods: Of 5424 patients who had undergone cholecystectomy from December 2006 to October 2013, 54 patients with primary gallbladder carcinomas confirmed by pathological diagnosis were identified. The patients were divided into two groups: diagnosed before operation (n=34) and UGC groups (n=20), of whom the clinical, pathological, and sonographic characteristics were compared. Results: No significant differences in age, gender, location of lesion, histological type, length of the gallbladder, existence of biliary sludge, and intestinal gas interference between the two groups were found (all P>0.05). The clinical symptoms, laboratory abnormalities, tumor markers, coexisting gallbladder stones, lesion size, lesion type, degree of differentiation, and tumor staging showed statistically significant differences between the two groups (all P<0.05). On ultrasound, the width of the gallbladder, gallbladder wall thickness, vascularity on color Doppler ultrasound, and bile volume in the gallbladder showed significant differences (all P<0.05). Conclusions: UGCs are commonly found at an early stage, often well-differentiated, wall thickened, and are generally accompanied with cholelithiasis. UGCs should be taken into consideration in cases with cholelithiasis or small gallbladder on ultrasound. PMID:26379911

  13. Use of B-mode ultrasonography for fetal sex determination in dogs.

    PubMed

    Gil, E M U; Garcia, D A A; Giannico, A T; Froes, T R

    2015-10-01

    Ultrasonographic determination of fetal sex in dogs has not previously been reported. The aim of this study was to describe a method for determination of intrauterine fetal sex using ultrasound. A cohort study was conducted in pregnant bitches to perform ultrasound examination of the fetal genitalia between the eighth and ninth week of gestation. Fetal sex was determined in utero by consensus agreement of two sonographers. Eighteen pregnant bitches were included in this study, and a total of 39 fetuses were evaluated. The accuracy of ultrasonography to determine the sex with a 95% confidence interval was 62.24% to female fetuses and 65.48% to male fetuses. The sonographic accuracy in determining fetal sex can be achieved at 100% when there are up to two fetuses in the litter; however, the accuracy of the technique reduces (66.7%) when more than three fetuses are present. This study describes the sonographic appearance of the external genitalia in canine fetuses in utero associated with a specific position of the fetus and reports that sex determination is possible between 55 and 58 days of gestation. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Reducing breast biopsies by ultrasonographic analysis and a modified self-organizing map

    NASA Astrophysics Data System (ADS)

    Zheng, Yi; Greenleaf, James F.; Gisvold, John J.

    1997-05-01

    Recent studies suggest that visual evaluation of ultrasound images could decrease negative biopsies of breast cancer diagnosis. However, visual evaluation requires highly experienced breast sonographers. The objective of this study is to develop computerized radiologist assistant to reduce breast biopsies needed for evaluating suspected breast cancer. The approach of this study utilizes a neural network and tissue features extracted from digital sonographic breast images. The features include texture parameters of breast images: characteristics of echoes within and around breast lesions, and geometrical information of breast tumors. Clusters containing only benign lesions in the feature space are then identified by a modified self- organizing map. This newly developed neural network objectively segments population distributions of lesions and accurately establishes benign and equivocal regions.t eh method was applied to high quality breast sonograms of a large number of patients collected with a controlled procedure at Mayo Clinic. The study showed that the number of biopsies in this group of women could be decreased by 40 percent to 59 percent with high confidence and that no malignancies would have been included in the nonbiopsied group. The advantages of this approach are that it is robust, simple, and effective and does not require highly experienced sonographers.

  15. High-frequency sonography of temporary and permanent dermal fillers.

    PubMed

    Grippaudo, Francesca Romana; Mattei, Mauro

    2010-08-01

    Dermal fillers are used widely; some have a permanent effect, whereas others are temporary. The aim of this study is to describe the ultrasonographic features of permanent and temporary fillers injected into patients for cosmetic purposes. Between December 2006 and April 2009, 36 subjects, aged 25-45, who had received lips or nasolabial fold filler augmentation, were enrolled for a high-frequency sonographic examination by a blinded investigator. The criteria for exclusion were a history of autoimmunity, infection, neoplastic diseases or episodes of local reactions to the injected filler. Twenty patients underwent a sonographic exam after the injection of a temporary filler (collagen or hyaluronic acid) by FRG; the rest were enrolled among patients seeking a consultation for further cosmetic reasons, but had been treated with an identifiable filler before. It was always possible to identify the filler at the site of injection. Seldom was it possible to discover a silent inflammatory reaction, otherwise unsuspected. The sonographic images differed according to the temporary or the permanent nature of the filler. Ultrasonography has proved to be a useful, non-invasive tool for the identification of the presence and type of the filler injected.

  16. TU-F-12A-09: GLCM Texture Analysis for Normal-Tissue Toxicity: A Prospective Ultrasound Study of Acute Toxicity in Breast-Cancer Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, T; Yang, X; Curran, W

    2014-06-15

    Purpose: To evaluate the morphologic and structural integrity of the breast glands using sonographic textural analysis, and identify potential early imaging signatures for radiation toxicity following breast-cancer radiotherapy (RT). Methods: Thirty-eight patients receiving breast RT participated in a prospective ultrasound imaging study. Each participant received 3 ultrasound scans: 1 week before RT (baseline), and at 6-week and 3-month follow-ups. Patients were imaged with a 10-MHz ultrasound on the four quadrant of the breast. A second order statistical method of texture analysis, called gray level co-occurrence matrix (GLCM), was employed to assess RT-induced breast-tissue toxicity. The region of interest (ROI) wasmore » 28 mm × 10 mm in size at a 10 mm depth under the skin. Twenty GLCM sonographic features, ratios of the irradiated breast and the contralateral breast, were used to quantify breast-tissue toxicity. Clinical assessment of acute toxicity was conducted using the RTOG toxicity scheme. Results: Ninety-seven ultrasound studies (776 images) were analyzed; and 5 out of 20 sonographic features showed significant differences (p < 0.05) among the baseline scans, the acute toxicity grade 1 and 2 groups. These sonographic features quantified the degree of tissue damage through homogeneity, heterogeneity, randomness, and symmetry. Energy ratio value decreased from 108±0.05 (normal) to 0.99±0.05 (Grade 1) and 0.84±0.04 (Grade 2); Entropy ratio value increased from 1.01±0.01 to 1.02±0.01 and 1.04±0.01; Contrast ratio value increased from 1.03±0.03 to 1.07±0.06 and 1.21±0.09; Variance ratio value increased from 1.06±0.03 to 1.20±0.04 and 1.42±0.10; Cluster Prominence ratio value increased from 0.98±0.02 to 1.01±0.04 and 1.25±0.07. Conclusion: This work has demonstrated that the sonographic features may serve as imaging signatures to assess radiation-induced normal tissue damage. While these findings need to be validated in a larger cohort, they suggest that ultrasound imaging may be used to improve early detection of normal-tissue toxicity in breast-cancer RT.« less

  17. Abdominal Ultrasound With Scintigraphic and Clinical Correlates in Infants With Sickle Cell Anemia: Baseline Data From the BABY HUG Trial

    PubMed Central

    McCarville, M. Beth; Luo, Zhaoyu; Huang, Xiangke; Rees, Renee C.; Rogers, Zora R.; Miller, Scott T.; Thompson, Bruce; Kalpatthi, Ram; Wang, Winfred C.

    2015-01-01

    OBJECTIVE The purpose of this study is to perform and evaluate baseline abdominal ultrasound in infants with sickle cell anemia who participated in the BABY HUG multiinstitutional randomized placebo-controlled trial of hydroxyurea therapy and to examine the potential relationships among ultrasound results and clinical, nuclear medicine, and laboratory data. SUBJECTS AND METHODS After local institutional review board approval and with informed guardian consent, 116 girls and 87 boys (age range, 7.5–18 months) with sickle cell anemia underwent standardized abdominal sonography at 14 institutions. Imaging was centrally reviewed by one radiologist who assessed and measured the spleen, kidneys, gallbladder, and common bile duct. Baseline physical assessment of spleen size, serum alanine aminotransferase and bilirubin levels, 99mTc sulfur colloid liver-spleen scans, and 99mTc diethylenetriaminepentaacetic acid clearance glomerular filtration rates (GFRs) were obtained. Analysis of variance and the Student test were performed to compare sonographic findings to published results in healthy children and to clinical and laboratory findings. RESULTS The mean (± SD) spleen volume (108 ± 47 mL) was significantly greater than published normal control values (30 ± 14 mL; p < 0.0001). There was no correlation between spleen volume and function assessed by liver-spleen scan. The mean GFR (125 ± 34 mL/min/1.73 m2) was elevated compared with control GFRs (92 ± 18 mL/min/1.73 m2). Renal volumes (right kidney, 29 ± 8 mL; left kidney, 31 ± 9 mL) were significantly greater than control volumes (right kidney, 27 ± 3 mL; left kidney, 27 ± 3 mL; p < 0.0001) and were positively correlated with GFR (p = 0.0009). Five percent of patients had sonographic biliary abnormalities (sludge, n = 6; dilated common bile duct, n = 2; and cholelithiasis and thickened gallbladder wall, n = 1 each). There was no correlation between biliary sonographic findings and laboratory results. CONCLUSION In infants with sickle cell anemia, sonographic spleen volume does not reflect function, but increased renal volume correlates with GFR and is consistent with hyperfiltration. Sonographic biliary abnormalities can occur early in life, while remaining clinically silent. PMID:21606305

  18. Use and accuracy of US guidance for image-guided injections of the temporomandibular joints in children with arthritis.

    PubMed

    Parra, Dimitri A; Chan, Melissa; Krishnamurthy, Ganesh; Spiegel, Lynn; Amaral, Joao G; Temple, Michael J; John, Philip R; Connolly, Bairbre L

    2010-09-01

    Juvenile idiopathic arthritis (JIA) has an incidence that ranges from 1 to 22 per 100,000 children worldwide, with involvement of the temporomandibular joint (TMJ) in 17-87% of patients. Intraarticular corticosteroid injections are beneficial in the local treatment of JIA and of other types of arthritis. To describe and assess the accuracy of an US-guided technique for visualization of needle placement within the TMJ in children. Between January 2000 and November 2007, 180 TMJ injections were performed during 116 encounters in 83 children with arthritis (71 girls, 12 boys; mean age 12.0 years). Access was obtained under sterile conditions using US guidance (linear 15-MHz or curvilinear 8-MHz transducers) in a coronal plane, and confirmed with CT. To minimize radiation, a limited focused CT protocol was developed. A bilateral injection was performed in 65 encounters (57%). Twenty-three children had repeat TMJ injections. All injections were performed using US guidance. CT confirmation was used in 127/180 TMJs (70%). In those confirmed with CT, the needle tip was intra-articular in 91% of cases. Triamcinolone hexacetonide was used in 92% of injections and triamcinolone acetonide in 8%. One major complication was encountered (skin atrophy at the injection site). In our experience, TMJ injections using sonographic guidance is a safe, effective and accurate procedure.

  19. Prospective randomized trial comparing magnetic resonance imaging (MRI)-guided in-bore biopsy to MRI-ultrasound fusion and transrectal ultrasound-guided prostate biopsy in patients with prior negative biopsies.

    PubMed

    Arsov, Christian; Rabenalt, Robert; Blondin, Dirk; Quentin, Michael; Hiester, Andreas; Godehardt, Erhard; Gabbert, Helmut E; Becker, Nikolaus; Antoch, Gerald; Albers, Peter; Schimmöller, Lars

    2015-10-01

    A significant proportion of prostate cancers (PCas) are missed by conventional transrectal ultrasound-guided biopsy (TRUS-GB). It remains unclear whether the combined approach using targeted magnetic resonance imaging (MRI)-ultrasound fusion-guided biopsy (FUS-GB) and systematic TRUS-GB is superior to targeted MRI-guided in-bore biopsy (IB-GB) for PCa detection. To compare PCa detection between IB-GB alone and FUS-GB + TRUS-GB in patients with at least one negative TRUS-GB and prostate-specific antigen ≥4 ng/ml. Patients were prospectively randomized after multiparametric prostate MRI to IB-GB (arm A) or FUS-GB + TRUS-GB (arm B) from November 2011 to July 2014. The study was powered at 80% to demonstrate an overall PCa detection rate of ≥60% in arm B compared to 40% in arm A. Secondary endpoints were the distribution of highest Gleason scores, the rate of detection of significant PCa (Gleason ≥7), the number of biopsy cores to detect one (significant) PCa, the positivity rate for biopsy cores, and tumor involvement per biopsy core. The study was halted after interim analysis because the primary endpoint was not met. The trial enrolled 267 patients, of whom 210 were analyzed (106 randomized to arm A and 104 to arm B). PCa detection was 37% in arm A and 39% in arm B (95% confidence interval for difference, -16% to 11%; p=0.7). Detection rates for significant PCa (29% vs 32%; p=0.7) and the highest percentage tumor involvement per biopsy core (48% vs 42%; p=0.4) were similar between the arms. The mean number of cores was 5.6 versus 17 (p<0.001). A limitation is the limited number of patients because of early cessation of accrual. This trial failed to identify an important improvement in detection rate for the combined biopsy approach over MRI-targeted biopsy alone. A prospective comparison between MRI-targeted biopsy alone and systematic TRUS-GB is justified. Our randomized study showed similar prostate cancer detection rates between targeted prostate biopsy guided by magnetic resonance imaging and the combination of targeted biopsy and systematic transrectal ultrasound-guided prostate biopsy. An important improvement in detection rates using the combined biopsy approach can be excluded. Copyright © 2015 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  20. The Massachusetts abscess rule: a clinical decision rule using ultrasound to identify methicillin-resistant Staphylococcus aureus in skin abscesses.

    PubMed

    Gaspari, Romolo J; Blehar, David; Polan, David; Montoya, Anthony; Alsulaibikh, Amal; Liteplo, Andrew

    2014-05-01

    Treatment failure rates for incision and drainage (I&D) of skin abscesses have increased in recent years and may be attributable to an increased prevalence of community-acquired methicillin-resistant Staphylococcus aureus (CA-MRSA). Previous authors have described sonographic features of abscesses, such as the presence of interstitial fluid, characteristics of abscess debris, and depth of abscess cavity. It is possible that the sonographic features are associated with MRSA and can be used to predict the presence of MRSA. The authors describe a potential clinical decision rule (CDR) using sonographic images to predict the presence of CA-MRSA. This was a pilot CDR derivation study using databases from two emergency departments (EDs) of patients presenting to the ED with uncomplicated skin abscesses who underwent I&D and culture of the abscess contents. Patients underwent ultrasound (US) imaging of the abscesses prior to I&D. Abscess contents were sent for culture and sensitivity. Two independent physicians experienced in soft tissue US blinded to the culture results and clinical data reviewed the images in a standardized fashion for the presence or absence of the predetermined image characteristics. In the instance of a disagreement between the initial two investigators, a third reviewer adjudicated the findings prior to analysis. The association between the primary outcome (presence of MRSA) and each sonographic feature was assessed using univariate and multivariate analysis. The reliability of each sonographic feature was measured by calculating the kappa (κ) coefficient of interobserver agreement. The decision tree model for the CDR was created with recursive partitioning using variables that were both reliable and strongly associated with MRSA. Of the total of 2,167 patients who presented with skin and soft tissue infections during the study period, 605 patients met inclusion criteria with US imaging and culture and sensitivity of purulence. Among the pathogenic organisms, MRSA was the most frequently isolated, representing 50.1% of all patients. Six of the sonographic features were associated with the presence of MRSA, but only four of these features were reliable using the kappa analysis. Recursive partitioning identified three independent variables that were both associated with MRSA and reliable: 1) the lack of a well-defined edge, 2) small volume, and 3) irregular or indistinct shape. This decision rule demonstrates a sensitivity of 89.2% (95% confidence interval [CI] = 84.7% to 92.7%), a specificity of 44.7% (95% CI = 40.9% to 47.8%), a positive predictive value of 57.9 (95% CI = 55.0 to 60.2), a negative predictive value of 82.9 (95% CI = 75.9 to 88.5), and an odds ratio (OR) of 7.0 (95% CI = 4.0 to 12.2). According to our putative CDR, patients with skin abscesses that are small, irregularly shaped, or indistinct, with ill-defined edges, are seven times more likely to demonstrate MRSA on culture. © 2014 by the Society for Academic Emergency Medicine.

  1. ARTVAL user guide : user guide for the ARTerial eVALuation computational engine.

    DOT National Transportation Integrated Search

    2015-06-01

    This document provides guidance on the use of the ARTVAL (Arterial Evaluation) computational : engine. The engine implements the Quick Estimation Method for Urban Streets (QEM-US) : described in Highway Capacity Manual (HCM2010) as the core computati...

  2. 77 FR 64148 - Advisory Committee on Reactor Safeguards (ACRS) Meeting of the ACRS Subcommittee on Regulatory...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-18

    ... Regulatory Guides (RG) RG 1.79, ````Preoperational Testing of Emergency Core Cooling Systems for Pressurized Water Reactors,'' Revision 2 and RG 1.79.1, ``Initial Test Program of Emergency Core Cooling Systems for...

  3. Explicit Instruction Elements in Core Reading Programs

    ERIC Educational Resources Information Center

    Child, Angela R.

    2012-01-01

    Classroom teachers are provided instructional recommendations for teaching reading from their adopted core reading programs (CRPs). Explicit instruction elements or what is also called instructional moves, including direct explanation, modeling, guided practice, independent practice, discussion, feedback, and monitoring, were examined within CRP…

  4. Deep rock damage in the San Andreas Fault revealed by P- and S-type fault-zone-guided waves

    USGS Publications Warehouse

    Ellsworth, William L.; Malin, Peter E.

    2011-01-01

    Damage to fault-zone rocks during fault slip results in the formation of a channel of low seismic-wave velocities. Within such channels guided seismic waves, denoted by Fg, can propagate. Here we show with core samples, well logs and Fg-waves that such a channel is crossed by the SAFOD (San Andreas Fault Observatory at Depth) borehole at a depth of 2.7 km near Parkfield, California, USA. This laterally extensive channel extends downwards to at least half way through the seismogenic crust, more than about 7 km. The channel supports not only the previously recognized Love-type- (FL) and Rayleigh-type- (FR) guided waves, but also a new fault-guided wave, which we name FF. As recorded 2.7 km underground, FF is normally dispersed, ends in an Airy phase, and arrives between the P- and S-waves. Modelling shows that FF travels as a leaky mode within the core of the fault zone. Combined with the drill core samples, well logs and the two other types of guided waves, FF at SAFOD reveals a zone of profound, deep, rock damage. Originating from damage accumulated over the recent history of fault movement, we suggest it is maintained either by fracturing near the slip surface of earthquakes, such as the 1857 Fort Tejon M 7.9, or is an unexplained part of the fault-creep process known to be active at this site.

  5. Ultrasound-guided core needle biopsy in diagnosis of abdominal and pelvic neoplasm in pediatric patients.

    PubMed

    Wang, Hailing; Li, Fangxuan; Liu, Juntian; Zhang, Sheng

    2014-01-01

    Ultrasound-guided core needle biopsy of abdominal and pelvic masses in adults has gained tremendous popularity. However, the application of the same treatment in children is not as popular because of apprehensions regarding inadequate tissues for the biopsy and accidental puncture of vital organs. Data of the application of ultrasound-guided core needle biopsy in 105 pediatric patients with clinically or ultrasound-diagnosed abdominopelvic masses were reviewed. Diagnostic procedures were conducted in our institution from May 2011 to May 2013. The biopsies were conducted on 86 malignant lesions and 19 benign lesions. 86 malignant tumors comprised neuroblastomas (30 cases), hepatoblastomas (15 cases), nephroblastomas (11 cases), and primitive neuroectodermal tumors/malignant small round cells (6 cases). Among malignant tumor cases, only a pelvic primitive neuroectodermal tumor did not receive a pathological diagnosis. Therefore, the biopsy accuracy was 98.8 % in malignant tumor. However, the biopsies for one neuroblastomas and one malignant small round cell tumor were inadequate for cytogenetic analysis. Therefore, 96.5 % of the malignant tumor patients received complete diagnosis via biopsy. 19 benign tumors comprised mature teratoma (10 cases), hemangioendothelioma (3 cases), paraganglioma (2 cases), and infection (2 cases). The diagnostic accuracy for benign neoplasm was 100 %. Five patients experienced postoperative complications, including pain (2 patients), bleeding from the biopsy site (2 patients), and wound infection (1 patient). Ultrasound-guided core needle biopsy is an efficient, minimally invasive, accurate, and safe diagnostic method that can be applied in the management of abdominal or pelvic mass of pediatric patients.

  6. Optically guided atom interferometer tuned to magic wavelength

    NASA Astrophysics Data System (ADS)

    Akatsuka, Tomoya; Takahashi, Tadahiro; Katori, Hidetoshi

    2017-11-01

    We demonstrate an atom interferometer operating on the 1S0-3P0 clock transition of 87Sr atoms in a “magic” optical guide, where the light shift perturbations of the guiding potential are canceled. As a proof-of-principle demonstration, a Mach-Zehnder interferometer is set horizontally to map the acceleration introduced by the focused optical guide. This magic guide interferometer on the clock transition is applicable to atomic elements where magic wavelengths can be found. Possible applications of the magic guide interferometer, including a hollow-core fiber interferometer and gradiometer, are discussed.

  7. Comparison of Histologic Core Portions Acquired from a Core Biopsy Needle and a Conventional Needle in Solid Mass Lesions: A Prospective Randomized Trial.

    PubMed

    Lee, Ban Seok; Cho, Chang-Min; Jung, Min Kyu; Jang, Jung Sik; Bae, Han Ik

    2017-07-15

    The superiority of endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) over EUS-guided fine needle aspiration (EUS-FNA) remains controversial. Given the lack of studies analyzing histologic specimens acquired from EUS-FNB or EUS-FNA, we compared the proportion of the histologic core obtained from both techniques. A total of 58 consecutive patients with solid mass lesions were enrolled and randomly assigned to the EUS-FNA or EUS-FNB groups. The opposite needle was used after the failure of core tissue acquisition using the initial needle with up to three passes. Using computerized analyses of the scanned histologic slide, the overall area and the area of the histologic core portion in specimens obtained by the two techniques were compared. No significant differences were identified between the two groups with respect to demographic and clinical characteristics. Fewer needle passes were required to obtain core specimens in the FNB group (p<0.001). There were no differences in the proportion of histologic core (11.8%±19.5% vs 8.0%±11.1%, p=0.376) or in the diagnostic accuracy (80.6% vs 81.5%, p=0.935) between two groups. The proportion of histologic core and the diagnostic accuracy were comparable between the FNB and FNA groups. However, fewer needle passes were required to establish an accurate diagnosis in EUS-FNB.

  8. Fashion Merchandising Guide.

    ERIC Educational Resources Information Center

    North Carolina State Dept. of Public Instruction, Raleigh. Div. of Vocational Education Services.

    Developed to address the needs of the apparel industry, this fashion merchandising curriculum guide is designed to assist marketing educators in effective instructional delivery. Introductory materials include the following: a course blueprint that illustrates units of instruction, core competencies in each unit, and specific objectives for each…

  9. A framework for managing core facilities within the research enterprise.

    PubMed

    Haley, Rand

    2009-09-01

    Core facilities represent increasingly important operational and strategic components of institutions' research enterprises, especially in biomolecular science and engineering disciplines. With this realization, many research institutions are placing more attention on effectively managing core facilities within the research enterprise. A framework is presented for organizing the questions, challenges, and opportunities facing core facilities and the academic units and institutions in which they operate. This framework is intended to assist in guiding core facility management discussions in the context of a portfolio of facilities and within the overall institutional research enterprise.

  10. FAST at MACH 20: clinical ultrasound aboard the International Space Station.

    PubMed

    Sargsyan, Ashot E; Hamilton, Douglas R; Jones, Jeffrey A; Melton, Shannon; Whitson, Peggy A; Kirkpatrick, Andrew W; Martin, David; Dulchavsky, Scott A

    2005-01-01

    Focused assessment with sonography for trauma (FAST) examination has been proved accurate for diagnosing trauma when performed by nonradiologist physicians. Recent reports have suggested that nonphysicians also may be able to perform the FAST examination reliably. A multipurpose ultrasound system is installed on the International Space Station as a component of the Human Research Facility. Nonphysician crew members aboard the International Space Station receive modest training in hardware operation, sonographic techniques, and remotely guided scanning. This report documents the first FAST examination conducted in space, as part of the sustained effort to maintain the highest possible level of available medical care during long-duration space flight. An International Space Station crew member with minimal sonography training was remotely guided through a FAST examination by an ultrasound imaging expert from Mission Control Center using private real-time two-way audio and a private space-to-ground video downlink (7.5 frames/second). There was a 2-second satellite delay for both video and audio. To facilitate the real-time telemedical ultrasound examination, identical reference cards showing topologic reference points and hardware controls were available to both the crew member and the ground-based expert. A FAST examination, including four standard abdominal windows, was completed in approximately 5.5 minutes. Following commands from the Mission Control Center-based expert, the crew member acquired all target images without difficulty. The anatomic content and fidelity of the ultrasound video were excellent and would allow clinical decision making. It is possible to conduct a remotely guided FAST examination with excellent clinical results and speed, even with a significantly reduced video frame rate and a 2-second communication latency. A wider application of trauma ultrasound applications for remote medicine on earth appears to be possible and warranted.

  11. Ultrasound-Guided Thrombin Injection Is a Safe and Effective Treatment for Femoral Artery Pseudoaneurysm in the Morbidly Obese.

    PubMed

    Yoo, Taehwan; Starr, Jean E; Go, Michael R; Vaccaro, Patrick S; Satiani, Bhagwan; Haurani, Mounir J

    2017-08-01

    Ultrasound-guided thrombin injection (UGTI) is a well-established practice for the treatment of femoral artery pseudoaneurysm. This procedure is highly successful but dependent on appropriate pseudoaneurysm anatomy and adequate ultrasound visualization. Morbid obesity can present a significant technical challenge due to increased groin adiposity, resulting in poor visualization of critical structures needed to safely perform the procedure. We aim to evaluate the safety and efficacy of UGTI to treat femoral artery pseudoaneurysm in the morbidly obese. This is a retrospective cohort study in which all patients who underwent UGTI at The Ohio State University Ross Heart Hospital from 2009 to 2014 were analyzed for patient characteristics and stratified by body mass index (BMI). Patients with BMI ≥ 35 were considered morbidly obese and were compared to patients with a BMI < 35. Outcome was failed treatment resulting in residual pseudoaneurysm. Our cohort consisted of 54 patients who underwent thrombin injection. There were 41 nonmorbidly obese and 13 morbidly obese patients. Mean age was 64.5 years. The cohort was 44.4% male. There were 6 failures, of which 1 underwent successful repeat injection and 5 underwent open surgical repair. There was no statistically significant difference in failure between nonmorbidly obese and morbidly obese patients (9.8% vs 15.4%, P = .45). There were no embolic/thrombotic complications. Ultrasound-guided thrombin injection is a safe and effective therapy in the morbidly obese for the treatment of femoral artery pseudoaneurysm. In the hands of experienced sonographers and surgeons with adequate visualization of the pseudoaneurysm sac, UGTI should remain a standard therapy in the morbidly obese.

  12. Ultrasound-guided therapeutic injections for neural pathology about the foot and ankle: a 4 year retrospective review.

    PubMed

    Walter, William R; Burke, Christopher J; Adler, Ronald S

    2017-06-01

    To describe a 4-year clinical experience with ultrasound-guided therapeutic perineural injections of peripheral nerves about the foot and ankle. Retrospective analysis of foot and ankle perineural injections performed between January 2012 and August 2016. Demographics, clinical indications, presence of structural pathology, immediate and interval pain relief, as well as complications were recorded. Fifty-nine therapeutic injections were performed among 46 patients, accounting for multiple injections in a single visit or multiple visits [mean age = 43 years (range 18-75), 31 female (67%) and 15 male (33%)]. Most commonly, perineural injections involved the hallux branch of the medial plantar nerve (n = 17, 22%). Least commonly, perineural injections involved the saphenous nerve (n = 3, 4%). Other injections in our series include sural (10), superficial (11) and deep (7) peroneal, medial (5) and lateral (3) plantar nerves, and the posterior tibial nerve (3). Ultrasound evaluation revealed structural abnormality associated with the nerve in 30 cases (51%)-most commonly thickening with perineural scarring (n = 14). Of 45 injections with complete documentation, immediate relief of symptoms was reported in 43 (96%) cases. Interval symptom relief was achieved in 23 injections [short term (n = 12), intermediate (n = 6), and long term (n = 5)] out of 38 for which follow-up was available (61%). Complications are rare, occurring in only one case. Ultrasound-guided perineural injections about the foot and ankle are safe and provide lasting symptomatic relief for many indications. Concomitant sonographic evaluation identifies structural abnormalities that may contribute to neuropathic symptoms, allowing targeting of injection or clinical therapy.

  13. Validation of a novel cost effective easy to produce and durable in vitro model for kidney-puncture and PNL-Simulation.

    PubMed

    Klein, Jan Thorsten; Rassweiler, Jens; Rassweiler-Seyfried, Marie-Claire Charlotte

    2018-03-29

    Nephrolithiasis is one of the most common diseases in urology. According to the EAU Guidelines, a percutaneous nephrolitholapaxy (PNL) is recommended when treating a kidney stone >2 cm. Nowadays PNL is performed even for smaller stones (<1 cm) using miniaturized instruments. The most challenging part of any PNL is the puncture of the planned site. PNL-novice surgeons need to practice this step in a safe environment with an ideal training model. We developed and evaluated a new, easy to produce, in-vitro model for the training of the freehand puncture of the kidney. Porcine kidneys with ureters were embedded in ballistic gel. Food coloring and preservative agent were added. We used the standard imaging modalities of X-ray and ultrasound to validate the training model. An additional new technique, the iPAD guided puncture, was evaluated. Five novices and three experts conducted 12 punctures for each imaging technique. Puncture time, radiation dose, and number of attempts to a successful puncture were measured. Mann-Whitney-U, Kruskal-Wallis, and U-Tests were used for statistical analyses. The sonographic guided puncture is slightly but not significantly faster than the fluoroscopic guided puncture and the iPAD assisted puncture. Similarly, the most experienced surgeon's time for a successful puncture was slightly less than that of the residents, and the experienced surgeons needed the least attempts to perform a successful puncture. In terms of radiation exposure, the residents had a significant reduction of radiation exposure compared to the experienced surgeons. The newly developed ballistic gel kidney-puncture model is a good training tool for a variety of kidney puncture techniques, with good content, construct, and face validity.

  14. Stomach in Contact with the Bladder: A Sonographic Sign of Left Congenital Diaphragmatic Hernia.

    PubMed

    Aiello, Horacio; Meller, César; Vázquez, Lucía; Otaño, Lucas

    2016-01-01

    The evaluation of the characteristics of the fetal stomach should be part of every routine prenatal ultrasound after 11 weeks. A position that has not been previously described in the literature is the stomach in contact with the bladder. We describe 6 cases with the ultrasonographic finding of the stomach in contact with the bladder, all of them in fetuses with left-sided congenital diaphragmatic hernia. Even though the reasons for this striking position of the stomach are not clear, our series highlights the fact that the visualization of the stomach in contact with the bladder may be a specific sonographic marker of congenital diaphragmatic hernia. © 2015 S. Karger AG, Basel.

  15. Sonographic Elastography of Mastitis.

    PubMed

    Sousaris, Nicholas; Barr, Richard G

    2016-08-01

    Sonographic elastography has been shown to be a useful imaging modality in characterizing breast lesions as benign or malignant. However, in preliminary research, mastitis has given false-positive findings on both strain and shear wave elastography. In this article, we review the findings in mastitis with and without abscess formation on both strain and shear wave elastography. The elastographic findings in all cases were suggestive of a malignancy according to published thresholds. In cases of mastitis with abscess formation, there is a characteristic appearance, with a central very soft area (abscess cavity) and a very stiff outer rim (edema and inflammation). This appearance should raise the suspicion of mastitis with abscess formation, since these findings are rare in breast cancers.

  16. Phenotip - a web-based instrument to help diagnosing fetal syndromes antenatally.

    PubMed

    Porat, Shay; de Rham, Maud; Giamboni, Davide; Van Mieghem, Tim; Baud, David

    2014-12-10

    Prenatal ultrasound can often reliably distinguish fetal anatomic anomalies, particularly in the hands of an experienced ultrasonographer. Given the large number of existing syndromes and the significant overlap in prenatal findings, antenatal differentiation for syndrome diagnosis is difficult. We constructed a hierarchic tree of 1140 sonographic markers and submarkers, organized per organ system. Subsequently, a database of prenatally diagnosable syndromes was built. An internet-based search engine was then designed to search the syndrome database based on a single or multiple sonographic markers. Future developments will include a database with magnetic resonance imaging findings as well as further refinements in the search engine to allow prioritization based on incidence of syndromes and markers.

  17. GUIDE FOR SELF-EXAMINATION AND PLANNING, THE CLUB ANALYSIS PROGRAM OF INDUSTRIAL MANAGEMENT CLUBS OF THE YMCA.

    ERIC Educational Resources Information Center

    MEYER, WILLIAM F.

    THIS GUIDE PROVIDES A QUESTION AND ANSWER METHOD IN WHICH LEADERS OF INDUSTRIAL MANAGEMENT CLUBS (IMC) MAY EVALUATE CLUB PROGRESS AND ACCOMPLISHMENTS. A REPORT OF A NATIONAL STUDY MADE BY GEORGE WILLIAMS COLLEGE ON I.M.C. MEMBERS AND THEIR ATTITUDES TOWARD CLUB PROGRESS IS PROVIDED AS A GUIDE FOR GATHERING INFORMATION. A SMALL CORE STEERING…

  18. Peacebook: A Resource Guide for Peace Studies at U.C. Berkeley, 1982-83 [and] 1983-84.

    ERIC Educational Resources Information Center

    Peace Studies Student Association.

    A series of essays and lists of resource materials as well as courses relevant to peace studies at the University of California Berkeley are presented in the two guides. Topics of the 1982-83 guide include the undergraduate major in Peace and Conflict Studies (PACS), a proposed curriculum, core courses, concentration area courses (social systems,…

  19. Quaternary sedimentary processes on the northwestern African continental margin - An integrated study using side-scan sonar, high-resolution profiling, and core data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Masson, D.G.; Huggett, Q.J.; Weaver, P.P.E.

    1991-08-01

    Side-scan sonar data, cores, and high-resolution profiles have been used to produce an integrated model of sedimentation for the continental margin west of the Canary Islands. Long-range side-scan sonar (GLORIA) data and a grid of 3.5-kHz profiles, covering some 200,000 km{sup 2} allow a regional appraisal of sedimentation. More detailed studies of selected areas have been undertaken using a new 30 kHz deep-towed side-scan sonar (TOBI) developed by the U.K. Institute of Oceanographic Sciences. Sediment cores have been used both to calibrate acoustic facies identified on sonographs and for detailed stratigraphic studies. The most recent significant sedimentation event in themore » area is to Saharan Sediment Slide, which carried material from the upper continental slope off West Africa to the edge of the Madeira Abyssal Plain, a distance of some 1000 km. The authors data shows the downslope evolution of the debris flow. Near the Canaries, it is a 20-m-thick deposit rafting coherent blocks of more than 1 km diameter; side-scan records show a strong flow-parallel fabric on a scale of tens of meters. On the lower slope, the debris flow thins to a few meters, the flow fabric disappears, and the rafted blocks decrease to meters in diameter. Side-scan data from the lower slope show that the Saharan Slide buries an older landscape of turbidity current channels, typically 1 km wide and 50 m deep. Evidence from the Madeiran Abyssal Plain indicates a history of large but infrequent turbidity currents, the emplacement of which is related to the effects of sea level changes on the northwest African margin.« less

  20. ACT-CCREC Core Research Program: Study Questions and Design. ACT Working Paper Series. WP-2015-01

    ERIC Educational Resources Information Center

    Cruce, Ty M.

    2015-01-01

    This report provides a non-technical overview of the guiding research questions and research design for the ACT-led core research program conducted on behalf of the GEAR UP College and Career Readiness Evaluation Consortium (CCREC). The core research program is a longitudinal study of the effectiveness of 14 GEAR UP state grants on the academic…

  1. Simulation study of core heating properties for recent FIREX-I experiments

    NASA Astrophysics Data System (ADS)

    Johzaki, Tomoyuki; Kai, Yusuke; Endo, Takuma; Nagatomo, Hideo; Sunahara, Atsushi; Sentoku, Yasuhiko; Taguchi, Toshihiro; Fujioka, Shinsuke; Shiraga, Hiroyuki; Azechi, Hiroshi; Firex Project Team

    2016-10-01

    The demonstration of efficient core heating is the main purpose of FIREX-I project, where Au cone-attached solid ball CD target is used. For the guiding of fast electron beam generated by relativistic laser plasma interactions, the kilo-Tesla-class longitudinal magnetic field is applied by a capacitor-coil target and kJ-class ns-durration high power laser. In addition, to reduce the collisional effect (energy loss and scattering of fast electrons) during propagation in the Au cone tip, we introduced opened-tip cone (tipless cone). To evaluate the core heating properties, we carried out the integrated simulations, which shows the enhancement of core heating efficiency due to the magnetic guiding and opened-tip cone by a factor of three. These simulation results will be shown and be compared with the experimental results. JSPS KAKENHI (26400532, 15H03758, 16H02245, 15K21767), NIFS Collaboration Research program (NIFS12KUGK05, NIFS14KNSS054), and FIREX project.

  2. Field analysis of the Cerenkov doubling of infrared coherent radiation utilizing an organic crystal core bounded by a glass capillary

    NASA Astrophysics Data System (ADS)

    Hayata, K.; Yanagawa, K.; Koshiba, M.

    1990-12-01

    A mode field analysis is presented of the second-harmonic electromagnetic wave that radiates from a nonlinear core bounded by a dielectric cladding. With this analysis the ultimate performance of the organic crystal-cored single-mode optical fiber waveguide as a guided-wave frequency doubler is evaluated through the solution of nonlinear parametric equations derived from Maxwell's equations under some assumptions. As a phase-matching scheme, a Cerenkov approach is considered because of advantages in actual device applications, in which the phase matching is achievable between the fundamental guided LP01 mode and the second-harmonic radiation (leaky) mode. Calculated results for organic cores made of benzil, 4-(N,N-dimethyl-amino)-3-acetamidonitrobenzen, 2-methyl-4-nitroaniline, and 4'-nitrobenzilidene-3-acetoamino-4-metxianiline provide useful data for designing an efficient fiber-optic wavelength converter utilizing nonlinear parametric processes. A detailed comparison is made between results for infinite and finite cladding thicknesses.

  3. Assessment of liver size by ultrasonography.

    PubMed

    Patzak, Monika; Porzner, Marc; Oeztuerk, Suemeyra; Mason, Richard Andrew; Wilhelm, Manfred; Graeter, Tilmann; Kratzer, Wolfgang; Haenle, Mark Martin; Akinli, Atilla Serif

    2014-09-01

    To determine liver span sonographically in a randomly selected population sample and identify factors that affect liver size. A total of 1,789 subjects (963 females, 826 males; mean age 41.8 ± 12.8 years) underwent sonographic examination of the liver in the midclavicular line to determine liver span. Subjects underwent physical examination and blood tests and completed a standardized interview questionnaire. The average liver span in the midclavicular line for the overall collective was 15.0 ± 1.5 cm; the average for females was 14.9 ± 1.6 cm and 15.1 ± 1.5 cm for males. Liver span exceeded 16 cm in 24.3% of subjects. Results of the multivariate analysis showed that, of the factors potentially influencing liver span, gender, age, body mass index, body height, fatty liver (p < 0.0001), waist-to-hip ratio (p = 0.015), and metabolic syndrome (p = 0.032) are significant. By contrast, diabetes mellitus, alcohol consumption, tobacco consumption, physical activity, and laboratory findings showed no influence. Sonographic measurement of liver span in the midclavicular line is a simple method for routine clinical use. Gender, age, body mass index, waist-to-hip ratio, body height, hepatic steatosis, and metabolic syndrome are factors associated with liver span. © 2014 Wiley Periodicals, Inc.

  4. Sonographic alteration of lenticular nucleus in focal task-specific dystonia of musicians.

    PubMed

    Walter, Uwe; Buttkus, Franziska; Benecke, Reiner; Grossmann, Annette; Dressler, Dirk; Altenmüller, Eckart

    2012-01-01

    In distinct movement disorders, transcranial sonography detects alterations of deep brain structures with higher sensitivity than other neuroimaging methods. Lenticular nucleus hyperechogenicity on transcranial sonography, thought to be caused by increased local copper content, has been reported as a characteristic finding in primary spontaneous dystonia. Here, we wanted to find out whether deep brain structures are altered in task-specific dystonia. The frequency of sonographic brainstem and basal ganglia changes was studied in an investigator-blinded setting in 15 musicians with focal task-specific hand dystonia, 15 musicians without dystonia, and 15 age- and sex-matched nonmusicians without dystonia. Lenticular nucleus hyperechogenicity was found in 12 musicians with task-specific dystonia, but only in 3 nondystonic musicians (Fisher's exact test, p = 0.001) and 2 nonmusicians (p < 0.001). The degree of lenticular nucleus hyperechogenicity in affected musicians correlated with age, but not with duration of music practice or duration of dystonia. In 2 of 3 affected musicians with normal echogenic lenticular nucleus, substantia nigra hyperechogenicity was found. Our findings support the idea of a pathogenetic link between primary spontaneous and task-specific dystonia. Sonographic basal ganglia alteration might indicate a risk factor that in combination with extensive fine motor training promotes the manifestation of task-specific dystonia. Copyright © 2011 S. Karger AG, Basel.

  5. Value of brain MRI when sonography raises suspicion of agenesis of the corpus callosum in fetuses.

    PubMed

    Jarre, A; Llorens Salvador, R; Montoliu Fornas, G; Montoya Filardi, A

    To evaluate the role of magnetic resonance imaging (MRI) in fetuses with a previous sonographic suspicion of agenesis of the corpus callosum (ACC) to confirm the diagnosis and to detect associated intracranial anomalies. Single-center retrospective and descriptive observational study of the brain MRI performed in 78 fetuses with ACC sonographic suspicion between January 2006 and December 2015. Two experts in fetal imaging reviewed the MRI findings to evaluate the presence and morphology of the corpus callosum. When ACC was detected the whole fetal brain anatomy was thoroughly studied to determine the presence of associated anomalies. Prenatal MR imaging findings were compared to postnatal brain MRI or necropsy findings when available. Fetal MRI diagnosed 45 cases of ACC, 12 were partial (26.7%) and 33 complete (73.3%). In 28 cases (62,2%) associated intracranial anomalies were identified. The most often abnormality was ventriculomegaly (78,6%), followed by cortical malformations (53,6%), posterior fossa (25%) and midline anomalies (10,7%). Fetal brain MRI has an important role in the diagnosis of ACC and detection of associated anomalies. To perform a fetal brain MRI is important in fetuses with sonographic suspicion of ACC. Copyright © 2017 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  6. Ultrasound Nomograms of the Fetal Optic Nerve Sheath Diameter.

    PubMed

    Haratz, Karina Krajden; Melcer, Yaakov; Leibovitz, Zvi; Feit, Hagit; Kerman-Sagie, Tally; Lev, Dorit; Ginath, Shimon; Gindes, Liat; Moron, Antonio Fernandes; Malinger, Gustavo

    2018-06-07

     To construct prenatal age-specific reference intervals for sonographic measurements of the optic nerve sheath diameter (ONSD) during gestation in normal fetuses.  Prospective cross-sectional study of fetuses assessed in antenatal ultrasound units between 2010 and 2014. The examination was based on a technique for the sonographic assessment of ONSD previously published by our group. The mean values and SDs of the ONSD were modeled as a function of the gestational week by curve estimation analysis based on the highest adjusted R2 coefficient. Repeatability tests were performed to assess intraobserver variability and interobserver agreement.  During the study period 364 healthy fetuses were enrolled. The mean values for the ONSD varied from 0.6 mm at 15 - 16 weeks to 2.8 mm at 37 - 38 weeks. The ONSD grows in a linear fashion throughout gestation, with a quadratic equation providing an optimal fit to the data (adjusted R2 = 0.957).  Sonographic age-specific references for the fetal ONSD are presented. This data may assist in the decision-making process in fetuses with a suspected increase in intracranial pressure, or anomalies affecting the development of optic stalks, such as optic hypoplasia and septo-optic dysplasia. © Georg Thieme Verlag KG Stuttgart · New York.

  7. First-trimester emergencies: a radiologist's perspective.

    PubMed

    Phillips, Catherine H; Wortman, Jeremy R; Ginsburg, Elizabeth S; Sodickson, Aaron D; Doubilet, Peter M; Khurana, Bharti

    2018-02-01

    The purpose of this article is to help the practitioner ensure early diagnosis and response to emergencies in the first trimester by reviewing anatomy of the developing embryo, highlighting the sonographic appearance of common first-trimester emergencies, and discussing key management pathways for treating emergent cases. First-trimester fetal development is a stepwise process that can be challenging to evaluate in the emergency department (ED) setting. This is due, in part, to the complex anatomy of early pregnancy, subtlety of the sonographic findings, and the fact that fewer than half of patients with ectopic pregnancy present with the classic clinical findings of a positive pregnancy test, vaginal bleeding, pelvic pain, and tender adnexa. Ultrasound (US) has been the primary approach to diagnostic imaging of first-trimester emergencies, with magnetic resonance imaging (MRI) and computed tomography (CT) playing a supportive role in a small minority of cases. Familiarity with the sonographic findings diagnostic of and suspicious for early pregnancy failure, ectopic pregnancy, retained products of conception, gestational trophoblastic disease, failed intrauterine devices, and complications associated with assisted reproductive technology (ART) is critical for any emergency radiologist. Evaluation of first-trimester emergencies is challenging, and knowledge of key imaging findings and familiarity with management pathways are needed to ensure early diagnosis and response.

  8. VAGINAL PROGESTERONE VERSUS CERVICAL CERCLAGE FOR THE PREVENTION OF PRETERM BIRTH IN WOMEN WITH A SONOGRAPHIC SHORT CERVIX, SINGLETON GESTATION, AND PREVIOUS PRETERM BIRTH: A SYSTEMATIC REVIEW AND INDIRECT COMPARISON META-ANALYSIS

    PubMed Central

    CONDE-AGUDELO, Agustin; ROMERO, Roberto; NICOLAIDES, Kypros; CHAIWORAPONGSA, Tinnakorn; O'BRIEN, John M.; CETINGOZ, Elcin; DA FONSECA, Eduardo; CREASY, George; SOMA-PILLAY, Priya; FUSEY, Shalini; CAM, Cetin; ALFIREVIC, Zarko; HASSAN, Sonia S.

    2012-01-01

    OBJECTIVE No randomized controlled trial has directly compared vaginal progesterone and cervical cerclage for the prevention of preterm birth in women with a sonographic short cervix in the midtrimester, singleton gestation, and previous spontaneous preterm birth. We performed an indirect comparison of vaginal progesterone versus cerclage, using placebo/no cerclage as the common comparator. STUDY DESIGN Adjusted indirect meta-analysis of randomized controlled trials. RESULTS Four studies evaluating vaginal progesterone versus placebo (158 patients) and five evaluating cerclage versus no cerclage (504 patients) were included. Both interventions were associated with a statistically significant reduction in the risk of preterm birth <32 weeks of gestation and composite perinatal morbidity and mortality compared with placebo/no cerclage. Adjusted indirect meta-analyses did not show statistically significant differences between vaginal progesterone and cerclage in reducing preterm birth or adverse perinatal outcomes. CONCLUSION Based on state-of-the-art methodology for indirect comparisons, either vaginal progesterone or cerclage are equally efficacious in the prevention of preterm birth in women with a sonographic short cervix in the midtrimester, singleton gestation, and previous preterm birth. The selection of the optimal treatment may depend upon adverse events, cost and patient/clinician preferences. PMID:23157855

  9. Exome sequencing for prenatal diagnosis of fetuses with sonographic abnormalities.

    PubMed

    Drury, Suzanne; Williams, Hywel; Trump, Natalie; Boustred, Christopher; Lench, Nicholas; Scott, Richard H; Chitty, Lyn S

    2015-10-01

    In the absence of aneuploidy or other pathogenic cytogenetic abnormality, fetuses with increased nuchal translucency (NT ≥ 3.5 mm) and/or other sonographic abnormalities have a greater incidence of genetic syndromes, but defining the underlying pathology can be challenging. Here, we investigate the value of whole exome sequencing in fetuses with sonographic abnormalities but normal microarray analysis. Whole exome sequencing was performed on DNA extracted from chorionic villi or amniocytes in 24 fetuses with unexplained ultrasound findings. In the first 14 cases sequencing was initially performed on fetal DNA only. For the remaining 10, the trio of fetus, mother and father was sequenced simultaneously. In 21% (5/24) cases, exome sequencing provided definitive diagnoses (Milroy disease, hypophosphatasia, achondrogenesis type 2, Freeman-Sheldon syndrome and Baraitser-Winter Syndrome). In a further case, a plausible diagnosis of orofaciodigital syndrome type 6 was made. In two others, a single mutation in an autosomal recessive gene was identified, but incomplete sequencing coverage precluded exclusion of the presence of a second mutation. Whole exome sequencing improves prenatal diagnosis in euploid fetuses with abnormal ultrasound scans. In order to expedite interpretation of results, trio sequencing should be employed, but interpretation can still be compromised by incomplete coverage of relevant genes. © 2015 John Wiley & Sons, Ltd.

  10. Evaluation of fetal anthropometric measures to predict the risk for shoulder dystocia.

    PubMed

    Burkhardt, T; Schmidt, M; Kurmanavicius, J; Zimmermann, R; Schäffer, L

    2014-01-01

    To evaluate the quality of anthropometric measures to improve the prediction of shoulder dystocia by combining different sonographic biometric parameters. This was a retrospective cohort study of 12,794 vaginal deliveries with complete sonographic biometry data obtained within 7 days before delivery. Receiver-operating characteristics (ROC) curves of various combinations of the biometric parameters, namely, biparietal diameter (BPD), occipitofrontal diameter (OFD), head circumference, abdominal diameter (AD), abdominal circumference (AC) and femur length were analyzed. The influences of independent risk factors were calculated and their combination used in a predictive model. The incidence of shoulder dystocia was 1.14%. Different combinations of sonographic parameters showed comparable ROC curves without advantage for a particular combination. The difference between AD and BPD (AD - BPD) (area under the curve (AUC) = 0.704) revealed a significant increase in risk (odds ratio (OR) 7.6 (95% CI 4.2-13.9), sensitivity 8.2%, specificity 98.8%) at a suggested cut-off ≥ 2.6 cm. However, the positive predictive value (PPV) was low (7.5%). The AC as a single parameter (AUC = 0.732) with a cut-off ≥ 35 cm performed worse (OR 4.6 (95% CI 3.3-6.5), PPV 2.6%). BPD/OFD (a surrogate for fetal cranial shape) was not significantly different between those with and those without shoulder dystocia. The combination of estimated fetal weight, maternal diabetes, gender and AD - BPD provided a reasonable estimate of the individual risk. Sonographic fetal anthropometric measures appear not to be a useful tool to screen for the risk of shoulder dystocia due to a low PPV. However, AD - BPD appears to be a relevant risk factor. While risk stratification including different known risk factors may aid in counseling, shoulder dystocia cannot effectively be predicted. Copyright © 2013 ISUOG. Published by John Wiley & Sons Ltd.

  11. [Two-year results of a prospective randomised controlled multicenter trial to compare open operative therapy vs. endoluminal venous laser therapy with and without high ligation for the therapy of varicose greater saphenous veins].

    PubMed

    Flessenkämper, I H; Stenger, D; Hartmann, M; Hartmann, K; Roll, S

    2015-02-01

    Therapeutic options for the treatment of varicosis of the great saphenous vein (gsv) include endoluminal laser therapy, crossectomy/stripping and a combination of both. In this paper we present data for clinical and sonographic inguinal recurrencies up to two years post operation. In an open multicentre, randomised three-arm trial, sonographic and clinical parameters were compared perioperatively, after 2, 6, 12 and 24 months between endoluminal venous laser therapy, high ligation and invaginating stripping and a combination of both (laser: 980 nm, continuous mode, 30 W, Biolitec®, Jena, Germany). Data of 449 patients were available for the perioperative and 2 months examination. 388 patients were followed up until 6, 380 patients for 12 and 332 patients for 24 months. We compared clinical recurrences, sonographic reflux findings, and reflux side branches in the inguinal region at the saphenofemoral junction. We found significantly more inguinal reflux and reflux side branches in the laser groups (p < 0.0001), however, there was no statistically significant relation between clinical recurrences and sonographic reflux. Over time, there were no intraindividual constant refluxes. Regarding the secondary endpoints oedema, lymphatic oedema, local disturbances of sensibility and irritations of the saphenous nerve, lymphatic oedema and irritations of the saphenous nerve were significantly more present in the two laser groups. After two years pain and restrictions in professional life were no longer relevant in all groups. Clinical recurrences developed both in the C/S and in the laser group but reflux into the gsv and into proximal side branches developed significantly more often in the laser group. In a long-term follow-up we have to investigate the importance of reflux side branches for the development of clinical recurrences to reveal differences between the three therapeutic strategies. Georg Thieme Verlag KG Stuttgart · New York.

  12. Frontonasal fold thickness-to-nasal bone length ratio as a prenatal sonographic marker for trisomy 21 in a low-risk population.

    PubMed

    Gonzalez, Ruben; Aedo, Socrates; Dezerega, Victor; Sepulveda, Waldo

    2013-05-01

    To report normative data for the fetal nasal bone length (NBL), frontonasal fold (FNF) thickness, and the FNF/NBL ratio and to study their performance in the sonographic screening of trisomy 21 in a normal, unselected Latin American population. Women undergoing a routine sonographic examination between 16 and 32 weeks' gestation at a primary health care center in Santiago, Chile, were prospectively recruited for NBL and FNF thickness measurements. Pregnancies with maternal/fetal complications were subsequently excluded from analysis. Correlations between NBL, FNF thickness, and FNF/NBL ratio and gestational age were assessed with the Spearman correlation coefficient (ρ). To generate reference percentiles for NBL and FNF thickness, adjusted regression models were derived using a statistical method for calculating reference percentiles of fetal biometric parameters. A total of 1922 cases complied with entry criteria. Both the NBL and the FNF thickness increased with gestational age. However, the FNF/NBL ratio remained constant (ρ= 0.016; P = .95), with a mean value of 0.68 and 95th and 99th percentile values of 0.84 and 0.90, respectively. During the study period, all 4 fetuses with trisomy 21 diagnosed in this low-risk population had an FNF/NBL ratio above the 99th percentile, whereas only 3 had NBL below the fifth percentile, and 3 had FNF thickness above the 95th percentile. The FNF/NBL ratio is a promising marker for the sonographic screening of trisomy 21 in the low-risk population; however, further prospective studies including larger numbers of fetuses with trisomy 21 are warranted to determine the clinical value of this marker. As the NBL is dependent on the ethnicity of the population screened, determination of normative data for NBL and the FNF/NBL ratio in different ethnic populations is also recommended before including this method in the routine screening for aneuploidy.

  13. 75 FR 9626 - Notice of Issuance of Regulatory Guide

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-03

    ... maintain variables and systems that can affect the fission process, the integrity of the reactor core, the... on some other defined basis. GDC 24 requires that interconnection of the protection and control..., Regulatory Guide Development Branch, Division of Engineering, Office of Nuclear Regulatory Research. [FR Doc...

  14. Native American Curriculum Resource Guide.

    ERIC Educational Resources Information Center

    McCoy, Melanie, Ed.

    This guide aims to assist the faculty member who wishes to integrate Native American materials into core courses of the curriculum. The first section is a bibliography of over 350 entries, primarily books and journal articles, arranged in the following categories: Native American bibliographies and general sources, history, economics,…

  15. Exploring Agriculture in America. Instructor Guide and Student Reference.

    ERIC Educational Resources Information Center

    Humphrey, John Kevin; And Others

    This curriculum guide is designed to provide instruction about agriculture for eighth-grade students in Missouri. Lessons included in the curriculum employ a problem-solving instructional approach. Student-oriented activities are included to provide opportunities for experiential learning. Core competencies and key skills are identified in…

  16. Core IV Materials for Metropolitan Agriculture/Horticulture Programs.

    ERIC Educational Resources Information Center

    Hemp, Paul; And Others

    This core curriculum guide consists of materials for use in presenting a 13-unit vocational agriculture course geared toward high school students living in metropolitan areas. Addressed in the individual units of the course are the following topics: employment in agricultural occupations, supervised occupational experience, leadership in…

  17. Cost comparison between ultrasound-guided 14-g large core breast biopsy and open surgical biopsy: an analysis for Austria.

    PubMed

    Gruber, R; Walter, E; Helbich, T H

    2010-06-01

    To examine the budget impact of ultrasound-guided 14-g large core breast biopsy (US-guided LCBB) by comparing the costs of US-guided LCBB and open surgical biopsy (OSB); to calculate the cost savings attributable to US-guided LCBB; and to assess the frequency with which US-guided LCBB obviates the need for an OSB. In a retrospective study, we reviewed 399 suspicious breast lesions on which US-guided LCBB and OSB or, in cases of benign histology, clinical follow-up, were performed. Cost savings were calculated using nationally allowed flat rates (A-drg) and patient charges. Costs were measured from both, a hospital and a socioeconomic perspective. Deterministic sensitivity analyses were simulated to assess the extent of achievable cost savings. Overall cost savings for US-guided LCBB over OSB were euro 977 (euro 2,337/euro 3,314) per case from a hospital perspective, resulting in a total cost decrease of 30% for the diagnosis of suspicious breast lesions. From a socioeconomic perspective, cost savings were euro 1,542 (euro 2,600/euro 4,142) per case, resulting in a 37% reduction in biopsy cost. US-guided LCBB obviated the need for a surgical procedure in 240 (60%) of 399 women. In all four sensitivity analyses, costs of US-guided LCBB remained lower than that of OSB. From an economic perspective, US-guided LCBB is highly recommended for the diagnosis of suspicious breast lesions, as this procedure reduces the cost of diagnosis substantially. In Austria, annual cost savings would be euro 18.5 million. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.

  18. The status of Fast Ignition Realization Experiment (FIREX) and prospects for inertial fusion energy

    NASA Astrophysics Data System (ADS)

    Azechi, H.; FIREX Project Team

    2016-05-01

    Here we report recent progress for the fast ignition inertial confinement fusion demonstration. The fraction of low energy (< 1 MeV) component of the relativistic electron beam (REB), which efficiently heats the fuel core, increases by a factor of 4 by enhancing pulse contrast of heating laser and removing preformed plasma sources. Kilo-tesla magnetic field is studied to guide the diverging REB to the fuel core. The transport simulation of the REB accelerated by the heating laser in the externally applied and compressed magnetic field indicates that the REB can be guided efficiently to the fuel core. The integrated simulation shows > 4% of the heating efficiency and > 4 keV of ion temperature are achievable by using GEKKO-XII and LFEX, properly designed cone-fuel and an external magnetic field.

  19. Value of cytopathologist-performed ultrasound-guided fine-needle aspiration as a screening test for ultrasound-guided core-needle biopsy in nonpalpable breast masses.

    PubMed

    Lieu, David

    2009-04-01

    Fine-needle aspiration (FNA) of breast masses in the United States has been on the decline for the last decade and has been largely replaced by ultrasound-guided core-needle biopsy (UG-CNB). Some studies show core-needle biopsy (CNB) is superior to FNA in terms of absolute sensitivity, specificity, and inadequate rate. However, the importance of a skilled aspirator, experienced cytopathologist, and immediate cytological evaluation (ICE) in FNA is often not considered. CNB is more expensive, invasive, risky, and painful than FNA. This prospective study examines the value of cytopathologist-performed ultrasound-guided FNA (UG-FNA) with ICE as a screening test for cytopathologist-performed UG-CNB on nonpalpable or difficult-to-palpate solid breast masses visible on ultrasound. One hundred twenty consecutive nonpalpable or difficult-to-palpate presumably solid breast masses in 109 female patients from January2, 2008 to June 30, 2008 underwent cytopathologist-performed UG-FNA with ICE. Twenty cases were converted to cytopathologist-performed UG-CNB because ICE was inadequate, hypocellular, atypical, suspicious, or malignant. Patients with clearly benign cytology did not undergo UG-CNB. UG-FNA with ICE reduced the percentage of patients undergoing UG-CNB by 87%. A new role for cytopathologist-performed UG-FNA of nonpalpable breast masses has been identified.

  20. Reproducibility of aortic intima-media thickness in infants using edge-detection software and manual caliper measurements.

    PubMed

    McCloskey, Kate; Ponsonby, Anne-Louise; Carlin, John B; Jachno, Kim; Cheung, Michael; Skilton, Michael R; Koleff, Jane; Vuillermin, Peter; Burgner, David

    2014-06-03

    Aortic intima-media thickness measured by transabdominal ultrasound (aIMT) is an intermediate phenotype of cardiovascular risk. We aimed to (1) investigate the reproducibility of aIMT in a population-derived cohort of infants; (2) establish the distribution of aIMT in early infancy; (3) compare measurement by edge-detection software to that by manual sonographic calipers; and (4) assess the effect of individual and environmental variables on image quality. Participants were term infants recruited to a population-derived birth cohort study. Transabdominal ultrasound was performed at six weeks of age by one of two trained operators. Thirty participants had ultrasounds performed by both operators on the same day. Data were collected on environmental (infant sleeping, presence of a sibling, use of sucrose, timing during study visit) and individual (post-conception age, weight, gender) variables. Two readers assessed image quality and measured aIMT by edge-detection software and a subset by manual sonographic calipers. Measurements were repeated by the same reader and between readers to obtain intra-observer and inter-observer reliability. Aortic IMT was measured successfully using edge-detection in 814 infants, and 290 of these infants also had aIMT measured using manual sonographic calipers. The intra-reader intra-class correlation (ICC) (n = 20) was 0.90 (95% CI 0.76, 0.96), mean difference 1.5 μm (95% LOA -39, 59). The between reader ICC using edge-detection (n = 20) was 0.92 (95% CI 0.82, 0.97) mean difference 2 μm (95% LOA -45.0, 49.0) and with manual caliper measurement (n = 290) the ICC was 0.84 (95% CI 0.80, 0.87) mean difference 5 μm (95% LOA -51.8, 61.8). Edge-detection measurements were greater than those from manual sonographic calipers (mean aIMT 618 μm (50) versus mean aIMT 563 μm (49) respectively; p < 0.001, mean difference 44 μm, 95% LOA -54, 142). With the exception of infant crying (p = 0.001), no associations were observed between individual and environmental variables and image quality. In a population-derived cohort of term infants, aIMT measurement has a high level of intra and inter-reader reproducibility. Measurement of aIMT using edge-detection software gives higher inter-reader ICC than manual sonographic calipers. Image quality is not substantially affected by individual and environmental factors.

  1. CT-Guided Transthoracic Core Biopsy for Pulmonary Tuberculosis: Diagnostic Value of the Histopathological Findings in the Specimen

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fukuda, Hozumi, E-mail: fkdhzmrad@mitsuihosp.or.jp; Ibukuro, Kenji; Tsukiyama, Toshitaka

    We evaluated the value of CT-guided transthoracic core biopsy for the diagnosis of mycobacterial pulmonary nodules. The 30 subjects in this study had pulmonary nodules that had been either diagnosed histopathologically as tuberculosis or were suspected as tuberculosis based on a specimen obtained by CT-guided transthoracic core biopsy. The histopathological findings, the existence of acid-fast bacilli in the biopsy specimens, and the clinical course of the patients after the biopsy were reviewed retrospectively. Two of the three histological findings for tuberculosis that included epithelioid cells, multinucleated giant cells and caseous necrosis were observed in 21 of the nodules which weremore » therefore diagnosed as histological tuberculosis. Six of these 21 nodules were positive for acid-fast bacilli, confirming the diagnosis of tuberculosis. Thirteen of the 21 nodules did not contain acid-fast bacilli but decreased in size in response to antituberculous treatment and were therefore diagnosed as clinical tuberculosis. Seven nodules with only caseous necrosis were diagnosed as suspected tuberculosis, with a final diagnosis of tuberculosis being made in 4 of the nodules and a diagnosis of old tuberculosis in 2 nodules. Two nodules with only multinucleated giant cells were diagnosed as suspected tuberculosis with 1 of these nodules being diagnosed finally as tuberculosis and the other nodule as a nonspecific granuloma. When any two of the three following histopathological findings - epithelioid cells, multinucleated giant cells or caseous necrosis - are observed in a specimen obtained by CT-guided transthoracic core biopsy, the diagnosis of tuberculosis can be established without the detection of acid-fast bacilli or Mycobacterium tuberculosis.« less

  2. Documenting the location of systematic transrectal ultrasound-guided prostate biopsies: correlation with multi-parametric MRI.

    PubMed

    Turkbey, Baris; Xu, Sheng; Kruecker, Jochen; Locklin, Julia; Pang, Yuxi; Shah, Vijay; Bernardo, Marcelino; Baccala, Angelo; Rastinehad, Ardeshir; Benjamin, Compton; Merino, Maria J; Wood, Bradford J; Choyke, Peter L; Pinto, Peter A

    2011-03-29

    During transrectal ultrasound (TRUS)-guided prostate biopsies, the actual location of the biopsy site is rarely documented. Here, we demonstrate the capability of TRUS-magnetic resonance imaging (MRI) image fusion to document the biopsy site and correlate biopsy results with multi-parametric MRI findings. Fifty consecutive patients (median age 61 years) with a median prostate-specific antigen (PSA) level of 5.8 ng/ml underwent 12-core TRUS-guided biopsy of the prostate. Pre-procedural T2-weighted magnetic resonance images were fused to TRUS. A disposable needle guide with miniature tracking sensors was attached to the TRUS probe to enable fusion with MRI. Real-time TRUS images during biopsy and the corresponding tracking information were recorded. Each biopsy site was superimposed onto the MRI. Each biopsy site was classified as positive or negative for cancer based on the results of each MRI sequence. Sensitivity, specificity, and receiver operating curve (ROC) area under the curve (AUC) values were calculated for multi-parametric MRI. Gleason scores for each multi-parametric MRI pattern were also evaluated. Six hundred and 5 systemic biopsy cores were analyzed in 50 patients, of whom 20 patients had 56 positive cores. MRI identified 34 of 56 positive cores. Overall, sensitivity, specificity, and ROC area values for multi-parametric MRI were 0.607, 0.727, 0.667, respectively. TRUS-MRI fusion after biopsy can be used to document the location of each biopsy site, which can then be correlated with MRI findings. Based on correlation with tracked biopsies, T2-weighted MRI and apparent diffusion coefficient maps derived from diffusion-weighted MRI are the most sensitive sequences, whereas the addition of delayed contrast enhancement MRI and three-dimensional magnetic resonance spectroscopy demonstrated higher specificity consistent with results obtained using radical prostatectomy specimens.

  3. A Guide to Credit Transfer

    ERIC Educational Resources Information Center

    Walls, Sandra; Pardy, John

    2010-01-01

    This guide is intended for students, career counsellors and others assisting vocational education and training (VET) students in the credit transfer process. It is based on research that set out to identify the core elements required to negotiate successful pathways from VET to higher education. Credit transfer structures between Deakin University…

  4. Standardized Curriculum for Outboard Marine Engine Mechanics.

    ERIC Educational Resources Information Center

    Mississippi State Dept. of Education, Jackson. Office of Vocational, Technical and Adult Education.

    This curriculum guide for outboard marine engine mechanics was developed by the state of Mississippi to standardize vocational education course titles and core contents. The objectives contained in this document are common to all outboard marine engine mechanics programs in the state. The guide contains objectives for outboard marine engine…

  5. [VIEW Level, Special Education Core Curriculum Manual.] I.E.P. Development Guide.

    ERIC Educational Resources Information Center

    Bergen County Region III, Demerest, NJ. Div. of Special Education.

    The Individualized Educational Program development guide is intended for handicapped students at the VIEW level (Vocational Instruction and Experience Workshop). Goals, objectives, and activities are specified for each of seven categories (sample subsections in parentheses): (1) assembly skills (collating, sorting, filing, folding); (2)…

  6. Agricultural Science Lab Activities. Instructor Guide. Volume 27, Number 2.

    ERIC Educational Resources Information Center

    Thompson, Gregory W.; And Others

    This instructor guide contains 20 laboratory activities for grades 9-10 Agricultural Science I-II classes. The activities are cross-referenced to Missouri Core Competencies and Key Skills. The activities are organized into the following areas: introductory (microscope use); animal nutrition (absorption of nutrients, bacteria and disease, enzyme…

  7. Social Science Curriculum Guide and Selected Multi-Media, 7-9.

    ERIC Educational Resources Information Center

    Gaydosh, Ronald; And Others

    GRADES OR AGES: Grades 7-9. SUBJECT MATTER: Social science; history. ORGANIZATION AND PHYSICAL APPEARANCE: The extensive introductory material includes rationale, definitions of the social science core disciplines, glossary of terms, guidelines for teaching, behavioral and long-range objectives, guide format, and descriptions of concepts. The…

  8. Latin I Resource Guide. Latin I Course Number: 61.041.

    ERIC Educational Resources Information Center

    Georgia State Dept. of Education, Atlanta. Office of Instructional Services.

    The guide contains classroom activities and instructional techniques to be used in implementing the first-year core Latin language curriculum for Georgia's public schools. Activities are correlated with goals and objectives specified in the state curriculum. Each provides information and directions for teachers and/or students and includes…

  9. Home Economics II. Basic Core. Tenth Grade.

    ERIC Educational Resources Information Center

    Benson, Ann

    Seven home economics curriculum areas for grade 10 are presented in this guide, with each area consisting of one or more instructional units as follows: (1) Career Exploration (obtaining a job, progress on the job, business etiquette); (2) Child Development (guiding the preschool child, middle childhood); (3) Clothing and Textiles (labeling,…

  10. Theoretical Perspectives Guiding QOL Indicator Projects

    ERIC Educational Resources Information Center

    Sirgy, M. Joseph

    2011-01-01

    Most of the theoretically based QOL indicators projects can be classified in terms of six major theoretical concepts: (a) socio-economic development (b) personal utility, (c) just society, (d) human development, (e) sustainability, and (f) functioning. I explain the core aspects of these six theoretical paradigms and show how they help guide QOL…

  11. Standardized Curriculum for Service Station Retailing.

    ERIC Educational Resources Information Center

    Mississippi State Dept. of Education, Jackson. Office of Vocational, Technical and Adult Education.

    This curriculum guide for service station retailing was developed by the state of Mississippi to standardize vocational education course titles and core contents. The objectives contained in this document are common to all service station retailing programs in the state. The guide contains objectives for service station retailing I and II courses.…

  12. The Process of Suicide Risk Assessment: Twelve Core Principles

    ERIC Educational Resources Information Center

    Granello, Darcy Haag

    2010-01-01

    Suicide risk assessment requires counselors to determine client risk factors, warning signs, and protective factors. The content of suicide assessment has received attention in the literature. The guiding principles of the process of suicide assessment, however, have not yet been articulated. This article contains 12 core process principles that…

  13. A Comprehensive Horticulture Curriculum Guide for New Jersey Schools.

    ERIC Educational Resources Information Center

    Rutgers, The State Univ., New Brunswick, NJ. Cook Coll.

    A horticultural core curriculum and draft copies of three horticultural cluster curricula are provided. Materials related to the curriculum development project appear first. The core curriculum is designed to provide broad initial instruction in horticulture for students in the first year of a secondary-level vocational horticulture program. The…

  14. Two Year Core Curriculum for Agricultural Education in Montana. Revised.

    ERIC Educational Resources Information Center

    Montana State Univ., Bozeman. Dept. of Agricultural and Industrial Education.

    This core curriculum consists of materials for use in conducting a two-year secondary level agricultural education course. Addressed in the individual units of the guide are the following topics: leadership; agricultural career planning; supervised occupational experience programs (SOEPs); agricultural mechanics (shop management and safety,…

  15. Competency-Based Common-Core Curriculum for Emergency Medical Technician Education.

    ERIC Educational Resources Information Center

    Arizona State Board of Directors for Community Colleges, Phoenix.

    This curriculum guide contains a listing of all common-core competencies that should be taught in Arizona community colleges in order to prepare students to meet the requirements of basic and refresher emergency medical technician training. Identified through a statewide project, the competencies cover the following topics: introduction to…

  16. Tolerancing the alignment of large-core optical fibers, fiber bundles and light guides using a Fourier approach.

    PubMed

    Sawyer, Travis W; Petersburg, Ryan; Bohndiek, Sarah E

    2017-04-20

    Optical fiber technology is found in a wide variety of applications to flexibly relay light between two points, enabling information transfer across long distances and allowing access to hard-to-reach areas. Large-core optical fibers and light guides find frequent use in illumination and spectroscopic applications, for example, endoscopy and high-resolution astronomical spectroscopy. Proper alignment is critical for maximizing throughput in optical fiber coupling systems; however, there currently are no formal approaches to tolerancing the alignment of a light-guide coupling system. Here, we propose a Fourier alignment sensitivity (FAS) algorithm to determine the optimal tolerances on the alignment of a light guide by computing the alignment sensitivity. The algorithm shows excellent agreement with both simulated and experimentally measured values and improves on the computation time of equivalent ray-tracing simulations by two orders of magnitude. We then apply FAS to tolerance and fabricate a coupling system, which is shown to meet specifications, thus validating FAS as a tolerancing technique. These results indicate that FAS is a flexible and rapid means to quantify the alignment sensitivity of a light guide, widely informing the design and tolerancing of coupling systems.

  17. Tolerancing the alignment of large-core optical fibers, fiber bundles and light guides using a Fourier approach

    PubMed Central

    Sawyer, Travis W.; Petersburg, Ryan; Bohndiek, Sarah E.

    2017-01-01

    Optical fiber technology is found in a wide variety of applications to flexibly relay light between two points, enabling information transfer across long distances and allowing access to hard-to-reach areas. Large-core optical fibers and light guides find frequent use in illumination and spectroscopic applications; for example, endoscopy and high-resolution astronomical spectroscopy. Proper alignment is critical for maximizing throughput in optical fiber coupling systems, however, there currently are no formal approaches to tolerancing the alignment of a light guide coupling system. Here, we propose a Fourier Alignment Sensitivity (FAS) algorithm to determine the optimal tolerances on the alignment of a light guide by computing the alignment sensitivity. The algorithm shows excellent agreement with both simulated and experimentally measured values and improves on the computation time of equivalent ray tracing simulations by two orders of magnitude. We then apply FAS to tolerance and fabricate a coupling system, which is shown to meet specifications, thus validating FAS as a tolerancing technique. These results indicate that FAS is a flexible and rapid means to quantify the alignment sensitivity of a light guide, widely informing the design and tolerancing of coupling systems. PMID:28430250

  18. The sonographic features of neonatal appendicitis: A case report.

    PubMed

    Si, Shu-Yu; Guo, Yi-Yi; Mu, Jian-Feng; Yan, Chao-Ying

    2017-11-01

    Neonatal appendicitis is extremely rare, and preoperative diagnosis is challenging. This study aimed to investigate the utility of ultrasound for the diagnosis of neonatal appendicitis. Four cases of neonatal appendicitis were included in this case series. One was a female infant and the other 3 were male infants; they were aged from 10 to 17 days. Neonatal appendicitis. Four newborns in our hospital were diagnosed with neonatal appendicitis by abdominal ultrasound. Their sonographic features were summarized and compared with surgical and pathological findings. In these infants, abdominal ultrasound demonstrated ileocecal bowel dilatation, intestinal and bowel wall thickening, and localized encapsulated effusion in the right lower quadrant and the abscess area, which was assumed to surround the appendix. Ultrasound is helpful for the diagnosis of neonatal appendicitis.

  19. Clinical application of a modern high-definition head-mounted display in sonography.

    PubMed

    Takeshita, Hideki; Kihara, Kazunori; Yoshida, Soichiro; Higuchi, Saori; Ito, Masaya; Nakanishi, Yasukazu; Kijima, Toshiki; Ishioka, Junichiro; Matsuoka, Yoh; Numao, Noboru; Saito, Kazutaka; Fujii, Yasuhisa

    2014-08-01

    Because of the remarkably improved image quality and wearability of modern head-mounted displays, a monitoring system using a head-mounted display rather than a fixed-site monitor for sonographic scanning has the potential to improve the diagnostic performance and lessen the examiner's physical burden during a sonographic examination. In a preclinical setting, 2 head-mounted displays, the HMZ-T2 (Sony Corporation, Tokyo, Japan) and the Wrap1200 (Vuzix Corporation, Rochester, NY), were found to be applicable to sonography. In a clinical setting, the feasibility of the HMZ-T2 was shown by its good image quality and acceptable wearability. This modern device is appropriate for clinical use in sonography. © 2014 by the American Institute of Ultrasound in Medicine.

  20. Twinkle artefact in the ultrasound diagnosis of superficial epidermoid cysts

    PubMed Central

    Clarke, Richard; Suresh, Priya; Thomas, Rose

    2016-01-01

    Aim The aim of the study was to evaluate whether the twinkle artefact is a valuable feature in the sonographic diagnosis of superficial epidermoid cysts. Materials and methods A retrospective search was undertaken of our institution’s Radiology Information System and pathology database to identify cases of superficial masses showing the twinkle artefact that proceeded to surgical excision. Results Eighteen superficial masses demonstrating the twinkle artefact were identified that were submitted for pathological analysis. Of these, 17 were confirmed to represent epidermoid cysts and only 1 case had an alternative diagnosis (proliferating trichilemmal cyst). Conclusion The presence of the twinkle artefact appears to be a specific and valuable ancillary sonographic feature for the diagnosis of superficial epidermoid cysts. PMID:27867407

  1. Propagation of Electromagnetic Waves in Slab Waveguide Structure Consisting of Chiral Nihility Claddings and Negative-Index Material Core Layer

    NASA Astrophysics Data System (ADS)

    Helal, Alaa N. Abu; Taya, Sofyan A.; Elwasife, Khitam Y.

    2018-06-01

    The dispersion equation of an asymmetric three-layer slab waveguide, in which all layers are chiral materials is presented. Then, the dispersion equation of a symmetric slab waveguide, in which the claddings are chiral materials and the core layer is negative index material, is derived. Normalized cut-off frequencies, field profile, and energies flow of right-handed and left-handed circularly polarized modes are derived and plotted. We consider both odd and even guided modes. Numerical results of guided low-order modes are provided. Some novel features, such as abnormal dispersion curves, are found.

  2. Terminology for contrast-enhanced sonography: a practical glossary.

    PubMed

    Catalano, Orlando; Migaleddu, Vincenzo; Quaia, Emilio; Caruso, Giuseppe

    2007-06-01

    The purpose of this glossary is to offer an updated guide to the correct terminology for contrast-enhanced sonography. This report was prepared by a panel of radiologists from the Sonography Section of the Italian Association of Medical Radiology. A leading author prepared a list of terms based on a comprehensive literature survey. The draft was analyzed by 3 experts on the topic of contrast-enhanced sonography. These reviewers reached a consensus and prepared the final version. A list of 137 terms is included. These terms are briefly defined. Their proper application is discussed, with special reference to potential misleading uses. Contrast-enhanced sonography is a relatively new diagnostic tool, now entering clinical practice in several countries. Use of appropriate, universal terminology is mandatory in the scientific setting to allow comparison between different published experiences. Additionally, use of clear, standardized terminology is necessary in the clinical setting to facilitate report understanding by the referring physician. Standardized, nonequivocal nomenclature may also help future diffusion of sonographic contrast media in countries where their application is still not approved.

  3. Ultrasound diagnosis and percutaneous treatment of Achilles tendon tethering: a case series.

    PubMed

    He, Lulu; Genin, Jason; Delzell, Patricia

    2016-09-01

    The purpose of this article is to report 3 cases of Kager's fat pad scarring and tethering to the deep surface of the Achilles tendon in patients with Achilles tendinosis symptomatology. The 3 patients were diagnosed sonographically by the use of a dynamic maneuver we described and named the "Kager's squeeze" technique. The key finding for diagnosis is the deformation and bowing of the deep fibers of the Achilles tendon during dynamic squeezing of Kager's fat pad. After diagnosis, the patients were treated with ultrasound-guided hydrodissection and scar release to restore normal motion between Kager's fat pad and the Achilles tendon. All 3 patients experienced significant clinical improvement shortly after treatment. Therefore, we suspect that Kager's fat pad scarring with Achilles tendon tethering may mimic or exacerbate Achilles tendinosis symptomatology and should be considered a possible diagnosis when conservative treatments for Achilles tendinosis fail. We demonstrate that Kager's fat pad scarring with Achilles tendon tethering can be diagnosed and treated with a simple in-office hydrodissection technique, leading to improved patient outcomes.

  4. Is uterine depth measurement by trans-vaginal ultrasound alone as accurate as measurement carried out by trans-abdominal ultrasound-guided trial transfer?

    PubMed

    Edris, Fawaz E

    2014-10-01

    To assess the reliability of trans-vaginal-scan (TVS) in measuring the uterine depth (UD) in comparison with ultrasound-guided trial-transfer (UTT). This prospective study was conducted in 66 consecutive patients undergoing in-vitro fertilization and embryo transfer (IVF-ET). The study took place in a private IVF center in Jeddah, Saudi Arabia between November 2013 and January 2014. The patients underwent UD measurements using TVS and UTT, sequentially. All scans were performed by a single sonographer, and all UTT were carried out by a single physician who was blinded to the TVS measurement. The median (95% confidence interval) UD measurement using the TVS method was 6.9 cm (5.0-12.5) and UTT was 7.1 cm (5.9-13.5), (p<0.0001). Fifteen patients (22.7%) had a difference of >1 cm between the 2 measurement modalities (group-B). When measured by UTT, 93.3% of patients in group-B had UD >/-8cm, compared with 9.8% of patients in group-A, (p<0.0001). Group-B had a significantly longer uterine cavity when measured by UTT (p<0.0001), and a trend towards significance when measured by TVS (p=0.055). The TVS measurements generally underestimated UD when compared with UTT. Trans-vaginal-scan is less reliable than UTT and should not be used as a substitute. Larger sample-size studies involving different personnel, and equipment is needed. 

  5. Diagnostic accuracy of 22/25-gauge core needle in endoscopic ultrasound-guided sampling: systematic review and meta-analysis.

    PubMed

    Oh, Hyoung-Chul; Kang, Hyun; Lee, Jae Young; Choi, Geun Joo; Choi, Jung Sik

    2016-11-01

    To compare the diagnostic accuracy of endoscopic ultrasound-guided core needle aspiration with that of standard fine-needle aspiration by systematic review and meta-analysis. Studies using 22/25-gauge core needles, irrespective of comparison with standard fine needles, were comprehensively reviewed. Pooled sensitivity, specificity, diagnostic odds ratio (DOR), and summary receiver operating characteristic curves for the diagnosis of malignancy were used to estimate the overall diagnostic efficiency. The pooled sensitivity, specificity, and DOR of the core needle for the diagnosis of malignancy were 0.88 (95% confidence interval [CI], 0.84 to 0.90), 0.99 (95% CI, 0.96 to 1), and 167.37 (95% CI, 65.77 to 425.91), respectively. The pooled sensitivity, specificity, and DOR of the standard needle were 0.84 (95% CI, 0.79 to 0.88), 1 (95% CI, 0.97 to 1), and 130.14 (95% CI, 34.00 to 495.35), respectively. The area under the curve of core and standard needle in the diagnosis of malignancy was 0.974 and 0.955, respectively. The core and standard needle were comparable in terms of pancreatic malignancy diagnosis. There was no significant difference in procurement of optimal histologic cores between core and standard needles (risk ratio [RR], 0.545; 95% CI, 0.187 to 1.589). The number of needle passes for diagnosis was significantly lower with the core needle (standardized mean difference, -0.72; 95% CI, -1.02 to -0.41). There were no significant differences in overall complications (RR, 1.26; 95% CI, 0.34 to 4.62) and technical failure (RR, 5.07; 95% CI, 0.68 to 37.64). Core and standard needles were comparable in terms of diagnostic accuracy, technical performance, and safety profile.

  6. Design, durability and low cost processing technology for composite fan exit guide vanes

    NASA Technical Reports Server (NTRS)

    Blecherman, S. S.

    1979-01-01

    A lightweight composite fan exit guide vane for high bypass ratio gas turbine engine application was investigated. Eight candidate material/design combinations were evaluated by NASTRAN finite element analyses. A total of four combinations were selected for further analytical evaluation, part fabrication by two ventors, and fatigue test in dry and wet condition. A core and shell vane design was chosen in which the unidirectional graphite core fiber was the same for all candidates. The shell material, fiber orientation, and ply configuration were varied. Material tests were performed on raw material and composite specimens to establish specification requirements. Pre-test and post-test microstructural examination and nondestructive analyses were conducted to determine the effect of material variations on fatigue durability and failure mode. Relevant data were acquired with respect to design analysis, materials properties, inspection standards, improved durability, weight benefits, and part price of the composite fan exit guide vane.

  7. Standardized Curriculum for Small Engine Repair.

    ERIC Educational Resources Information Center

    Mississippi State Dept. of Education, Jackson. Office of Vocational, Technical and Adult Education.

    This curriculum guide for small engine repair was developed by the state of Mississippi to standardize vocational education course titles and core contents. The objectives contained in this document are common to all small engine repair programs in the state. The guide contains objectives for small engine repair I and II courses. Units in course I…

  8. Standardized Curriculum for Metal Trades.

    ERIC Educational Resources Information Center

    Mississippi State Dept. of Education, Jackson. Office of Vocational, Technical and Adult Education.

    This curriculum guide for the metal trades was developed by the state of Mississippi to standardize vocational education course titles and core contents. The objectives contained in this document are common to all metal trades programs in the state. The guide contains objectives for Metal Trades I and II courses. Units in Metal Trades I cover the…

  9. Social Science Curriculum Guide and Selected Multi-Media, K-6.

    ERIC Educational Resources Information Center

    Gaydosh, Ronald; And Others

    GRADES OR AGES: K-6. SUBJECT MATTER: Social science. ORGANIZATION AND PHYSICAL APPEARANCE: The introductory material includes an explanation of the rationale, definitions of the social science core disciplines, glossary of terms, guidelines for teaching, and descriptions of concepts. The main body of the guide is designed in a five-column…

  10. Asperger Syndrome--Practical Strategies for the Classroom: A Teacher's Guide.

    ERIC Educational Resources Information Center

    Thomas, George; Barratt, Penny; Clewley, Heather; Joy, Helen; Potter, Mo; Whitaker, Philip

    This guide to Asperger syndrome for teachers describes the underlying impairments of the condition, explains how these may lead to problems in school, and offers practical management suggestions. The first part gives an overview of Asperger syndrome and outlines the three core areas of impairment--social interaction, communication, and lack of…

  11. Highway Maintenance Equipment Operator: Basic Core. Training Materials.

    ERIC Educational Resources Information Center

    Perky, Sandra Dutreau; And Others

    This basic core curriculum is part of a three-part series of instructional guides designed for use in teaching a course in highway maintenance equipment operation. Addressed in the individual units of the curriculum, after an orientation unit, are safety; basic math; basic hand tools; procedures for loading. lashing, and unloading equipment;…

  12. Fundamentals of Marketing. Missouri Marketing Education Curriculum. Competency Listing. Revised.

    ERIC Educational Resources Information Center

    Smith, Clifton L.

    This guide lists the core curriculum competencies expected to be developed by students in secondary Fundamentals of Marketing courses in Missouri. It was developed through revision of the prior core curriculum by a project team with input from all the marketing instructors in the state. Competencies listed in the revised fundamentals of marketing…

  13. Kansas Vocational Agriculture Education. Basic Core Curriculum Project, Horticulture III.

    ERIC Educational Resources Information Center

    Albracht, James, Ed.

    This secondary horticulture curriculum guide is one of a set of three designated as the basic core of instruction for horticulture programs in Kansas. Units of instruction are presented in eight sections: (1) Human Relations, (2) Business Operations, (3) Greenhouse, (4) Retail Flowershop Operation, (5) Landscape Nursery, (6) Lawn Maintenance, (7)…

  14. Kansas Vocational Agriculture Education. Basic Core Curriculum Project, Horticulture II.

    ERIC Educational Resources Information Center

    Albracht, James, Ed.

    This second horticulture guide is one of a set of three designated as the basic core of instruction for horticulture programs in Kansas. Units of instruction are presented in eight sections: (1) Leadership, (2) Supervised Occupational Experience, (3) Plant Propagation, (4) Soil and Plant Growth Media, (5) Fertilizers, (6) Greenhouse, (7) Plant…

  15. 78 FR 64027 - Preoperational Testing of Emergency Core Cooling Systems for Pressurized-Water Reactors

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-25

    ...The U.S. Nuclear Regulatory Commission (NRC) is issuing a revision to regulatory guide (RG), 1.79, ``Preoperational Testing of Emergency Core Cooling Systems for Pressurized-Water Reactors.'' This RG is being revised to incorporate guidance for preoperational testing of new pressurized water reactor (PWR) designs.

  16. A Guide to Addressing Multiple Priorities in Core Content Instruction for Students with Severe Disabilities

    ERIC Educational Resources Information Center

    Root, Jenny R.; Knight, Victoria F.; Mims, Pamela J.

    2017-01-01

    Instruction in academic core content provides students with moderate to severe disabilities a full educational opportunity that promotes current and future options in the community and can complement acquisition of daily living skills. However, high school teachers face many challenges in balancing instructional priorities given the mission to…

  17. Why the Common Core Changes Math Instruction

    ERIC Educational Resources Information Center

    Faulkner, Valerie N.

    2013-01-01

    The Common Core math standards promote several important differences in how math concepts are taught and should be talked about. These changes will make it easier for younger students to comprehend and adapt to more complex concepts in the later grades. This guide should help elementary teachers make changes and adaptations that are in line the…

  18. Kansas Vocational Agriculture Education. Basic Core Curriculum Project, Horticulture I.

    ERIC Educational Resources Information Center

    Albracht, James, Ed.

    This secondary horticulture curriculum guide is one of a set of three designated as the basic core of instruction for horticulture programs in Kansas. Units of instruction are presented in thirteen sections: (1) Orientation and Careers, (2) Leadership and Future Farmers of America, (3) Supervised Occupational Experience Program, (4) Plant…

  19. Diagnostic Yield of CT-Guided Percutaneous Transthoracic Needle Biopsy for Diagnosis of Anterior Mediastinal Masses.

    PubMed

    Petranovic, Milena; Gilman, Matthew D; Muniappan, Ashok; Hasserjian, Robert P; Digumarthy, Subba R; Muse, Victorine V; Sharma, Amita; Shepard, Jo-Anne O; Wu, Carol C

    2015-10-01

    The purpose of this study was to evaluate the diagnostic yield and accuracy of CT-guided percutaneous biopsy of anterior mediastinal masses and assess prebiopsy characteristics that may help to select patients with the highest diagnostic yield. Retrospective review of all CT-guided percutaneous biopsies of the anterior mediastinum conducted at our institution from January 2003 through December 2012 was performed to collect data regarding patient demographics, imaging characteristics of biopsied masses, presence of complications, and subsequent surgical intervention or medical treatment (or both). Cytology, core biopsy pathology, and surgical pathology results were recorded. A per-patient analysis was performed using two-tailed t test, Fisher's exact test, and Pearson chi-square test. The study cohort included 52 patients (32 men, 20 women; mean age, 49 years) with mean diameter of mediastinal mass of 6.9 cm. Diagnostic yield of CT-guided percutaneous biopsy was 77% (40/52), highest for thymic neoplasms (100% [11/11]). Non-diagnostic results were seen in 12 of 52 patients (23%), primarily in patients with lymphoma (75% [9/12]). Fine-needle aspiration yielded the correct diagnosis in 31 of 52 patients (60%), and core biopsy had a diagnostic rate of 77% (36/47). None of the core biopsies were discordant with surgical pathology. There was no statistically significant difference between the diagnostic and the nondiagnostic groups in patient age, lesion size, and presence of necrosis. The complication rate was 3.8% (2/52), all small self-resolving pneumothoraces. CT-guided percutaneous biopsy is a safe diagnostic procedure with high diagnostic yield (77%) for anterior mediastinal lesions, highest for thymic neoplasms (100%), and can potentially obviate more invasive procedures.

  20. Appendiceal outer diameter as an indicator for differentiating appendiceal mucocele from appendicitis.

    PubMed

    Lien, Wan-Ching; Huang, Shih-Pei; Chi, Chun-Lin; Liu, Kao-Lang; Lin, Ming-Tsan; Lai, Ting-I; Liu, Yueh-Ping; Wang, Hsiu-Po

    2006-11-01

    Patients with appendiceal mucocele (AM) commonly present with features indicative of acute appendicitis. In emergency departments, accurate preoperative diagnosis is crucial to prompt appropriate treatment. This study investigates the clinical and sonographic characteristics of AM, which may prove useful in preoperatively differentiating AM from appendicitis. This case-control study compares the clinical and sonographic findings of 16 histologically confirmed AM with sex- and age-matched control subjects (n = 64) with appendicitis by a 1:4 ratio. Conditional logistic regression was applied to estimate the odds ratio (OR) and 95% confidence intervals (CI) of clinical and sonographic parameters associated with AM. Univariate analysis demonstrated that the larger appendiceal outer diameter by sonography was positively correlated with diagnosis of AM (OR, 2.31; 95% CI, 1.42-3.72) and right lower quadrant abdominal pain was negatively correlated (OR, 0.38; 95% CI, 0.17-0.82). However, multiple regression analysis suggested that only outer diameter remained significant (OR, 2.21; 95% CI, 1.36-3.59) after adjusting for age, sex, and right lower quadrant pain. An outer diameter of 15 mm or more was predictive of AM diagnosis, with a sensitivity of 83% and specificity of 92%. When the threshold is set at 15 mm, appendiceal outer diameter by sonography is a useful preoperative measurement for differentiating between AM and acute appendicitis.

  1. New Optic Nerve Sonography Quality Criteria in the Diagnostic Evaluation of Traumatic Brain Injury

    PubMed Central

    Johnson, Garrett G. R. J.; Gillman, Lawrence M.; Faqihi, Fahad; Balhamar, Abdullah; Mahmood, Nasir Nasim; Alharthy, Abdulrahman; Lazaridis, Christos

    2018-01-01

    Background New sonographic quality criteria to optimize optic nerve sheath diameter (ONSD) measurements were suggested. The latter were correlated to elevated intracranial pressure (ICP) in traumatic brain injury (TBI). Aim We investigated whether ONSD measurements were correlated to simultaneous ICP measurements in severe TBI. Methods Forty patients with severe TBI (Marshall Scale ≥II and GCS ≤8) participated in the study. All patients had an intraparenchymal ICP catheter inserted, while ONSD was measured bilaterally, upon admission and over the next 48 hours, based on the new sonographic criteria. A total of 400 ONSD measurements were performed, while mean ONSD values of both eyes were used in the analysis. Results ONSD measurements were strongly correlated to ICP values (r=0.74, p < 0.0001). Receiver operator curve (ROC) analysis revealed that the ONSD cutoff value for predicting elevated ICP was 6.4 mm when using the mean of both eyes (AUC = 0.88, 95% CI = 0.80 to 0.95; sensitivity = 85.3%, specificity = 82.6%). Linear regression analysis nested models revealed that sex (p=0.006) and height (p=0.04) were significant predictors of ONSD values. Conclusion When applying the new sonographic quality criteria, ONSD is strongly correlated to ICP in severe TBI. Whether to use such criteria to monitor ONSD as a proxy for ICP trend in TBI remains to be further explored. PMID:29854448

  2. Sonographic findings of ruptured epidermal inclusion cysts in superficial soft tissue: emphasis on shapes, pericystic changes, and pericystic vascularity.

    PubMed

    Jin, Wook; Ryu, Kyung Nam; Kim, Gou Young; Kim, Hyun Cheol; Lee, Jae Hoon; Park, Ji Seon

    2008-02-01

    The purpose of this study was to retrospectively evaluate the sonographic findings of ruptured epidermal inclusion cysts in superficial soft tissue, with an emphasis on shapes, pericystic changes, and pericystic vascularity. The cases of 61 patients with surgically confirmed epidermal inclusion cysts were reviewed, and 13 patients were found to have ruptured cysts. The Ethics Committees of our institutions did not require patient approval or informed patient consent for this retrospective study. We evaluated the shapes, sizes, locations, pericystic changes, and pericystic vascularity for the 13 cases. The shapes of the ruptured epidermal inclusion cysts were classified into 3 types: with lobulations (type I, 2 cases), with protrusions (type II, 8 cases), and with abscess pocket formations (type III, 3 cases). The mean long diameter of the cysts was 3 cm. Common sites of ruptured epidermal inclusion cysts were the plantar surface of the metatarsophalangeal joint (4 cases) and buttocks (3 cases). Pericystic changes were noted in all of the type II and III cysts. Increased vascularity on color Doppler sonography was prominent in 3 type II cysts and 3 type III cysts. Deep abscess formation was noted in the epidermal inclusion cysts, especially for the type III cysts. A ruptured epidermal inclusion cyst visualized by sonography had variable shapes; the sonographic findings can be useful for obtaining a correct diagnosis of a ruptured epidermal inclusion cyst.

  3. Sonographic measurement of abdominal esophageal length as a diagnostic tool in gastroesophageal reflux disease in infants.

    PubMed

    Dehdashti, Hamid; Dehdashtian, Masoud; Rahim, Fakher; Payvasteh, Mehrdad

    2011-01-01

    This study was conducted to provide sonographic measurements of the abdominal esophagus length in neonates and infants with and without gastroesophageal reflux disease (GERD) and to investigate its diagnostic value. GERD severity was also evaluated and correlated with esophageal length. It is a prospective case-control study. This prospective case-control study comprised 235 neonates and infants (120 without reflux and 115 with reflux). There were 40 children without reflux in each of three age categories: less than 1 month, 1-6 months, and 6-12 months. Of the children with reflux, 40 were less than 1 month old; 37, 1-6 months; and 38, 6-12 months. The abdominal esophagus was measured from its entrance into the diaphragm to the base of gastric folds in fed infants. GERD was sonographically diagnosed and confirmed by a barium meal. The number of refluxes during a 10-min period were recorded. Neonates and infants with reflux had a significantly shorter abdominal esophagus than subjects without reflux: the mean difference in neonates, 4.65 mm; 1-6 months, 4.57 mm; 6-12 months, 3.61 mm. Children with severe reflux had a shorter esophagus compared with those with mild and moderate reflux only in the neonate group. Therefore, thinking of GERD and carefully looking for its symptoms is necessary to avoid unnecessary utilization of healthcare resources in children with severe reflux.

  4. Accuracy and safety of ultrasound-guided percutaneous needle core biopsy of renal masses

    PubMed Central

    Wang, Xianding; Lv, Yuanhang; Xu, Zilin; Aniu, Muguo; Qiu, Yang; Wei, Bing; Li, Xiaohong; Wei, Qiang; Dong, Qiang; Lin, Tao

    2018-01-01

    Abstract Our aim is to determine the sufficiency, accuracy, and safety of ultrasound-guided percutaneous needle core biopsy of renal masses in Chinese patients. Patients who had undergone ultrasound-guided needle core renal mass biopsy from June 2012 to June 2016 at West China Hospital, China were retrospectively reviewed. The information obtained included demographics, mass-related parameters, biopsy indications, technique, complications, pathologic results, and follow-up. Concordance of surgical resection pathology and follow-up data were assessed. Renal mass biopsies were performed in 106 patients. Thirty-nine (36.8%) were asymptomatic. The male/female ratio was 60/46, with a median age of 49.5 years. Median mass size was 8.1 cm (range 1.8–20). Biopsy was performed through a 16-gauge needle, with median cores of 2 taken (range 1–5). Only one significant biopsy-related complication (hemorrhage requiring transfusion) was encountered. An adequate tissue sample was obtained in 97.2% (103/106) of biopsies. Eighty-seven biopsies (82.1%) showed malignant neoplasms, 16 (15.1%) yielded benignity, and 3 (2.8%) were nondiagnostic. After biopsy, 46 patients (43.4%) underwent surgery. Compared with the subsequent mass resection pathology, the biopsy diagnoses were identical in 43 cases. The accuracy rate of biopsy distinguishing malignant from benign lesions was 99.1%, and the rate for determining tumor histological type (excluding the nondiagnostic biopsies) was 95.1%. The sensitivity and specificity in detecting malignancy were 98.9% and 100%, respectively. In several situations, there is still a role for biopsy before intervention. Percutaneous needle core biopsy under ultrasonography guidance is highly accurate and safe, and can determine the proper management of undefinable masses. PMID:29595650

  5. Imaging-Guided Core-Needle Breast Biopsy: Impact of Meditation and Music Interventions on Patient Anxiety, Pain, and Fatigue.

    PubMed

    Soo, Mary Scott; Jarosz, Jennifer A; Wren, Anava A; Soo, Adrianne E; Mowery, Yvonne M; Johnson, Karen S; Yoon, Sora C; Kim, Connie; Hwang, E Shelley; Keefe, Francis J; Shelby, Rebecca A

    2016-05-01

    To evaluate the impact of guided meditation and music interventions on patient anxiety, pain, and fatigue during imaging-guided breast biopsy. After giving informed consent, 121 women needing percutaneous imaging-guided breast biopsy were randomized into three groups: (1) guided meditation; (2) music; (3) standard-care control group. During biopsy, the meditation and music groups listened to an audio-recorded, guided, loving-kindness meditation and relaxing music, respectively; the standard-care control group received supportive dialogue from the biopsy team. Immediately before and after biopsy, participants completed questionnaires measuring anxiety (State-Trait Anxiety Inventory Scale), biopsy pain (Brief Pain Inventory), and fatigue (modified Functional Assessment of Chronic Illness Therapy-Fatigue). After biopsy, participants completed questionnaires assessing radiologist-patient communication (modified Questionnaire on the Quality of Physician-Patient Interaction), demographics, and medical history. The meditation and music groups reported significantly greater anxiety reduction (P values < .05) and reduced fatigue after biopsy than the standard-care control group; the standard-care control group reported increased fatigue after biopsy. The meditation group additionally showed significantly lower pain during biopsy, compared with the music group (P = .03). No significant difference in patient-perceived quality of radiologist-patient communication was noted among groups. Listening to guided meditation significantly lowered biopsy pain during imaging-guided breast biopsy; meditation and music reduced patient anxiety and fatigue without compromising radiologist-patient communication. These simple, inexpensive interventions could improve women's experiences during core-needle breast biopsy. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  6. Refractory Depression, Fatigue, Irritable Bowel Syndrome, and Chronic Pain: A Functional Medicine Case Report.

    PubMed

    Plotnikoff, Gregory; Barber, Melissa

    2016-01-01

    Single-disorder or single-organ-system clinical practice guidelines are often of limited usefulness in guiding effective management of patients with chronic multidimensional signs and symptoms. The presence of multiple long-standing medical problems in a given patient despite intensive medical effort suggests that addressing systemic core imbalances could complement more narrowly focused approaches. A 72-year-old man experiencing longstanding depression, fatigue, irritable bowel syndrome, and chronic pain in the context of additional refractory illnesses was assessed and treated, guided by a system-oriented approach to underlying core imbalances termed functional medicine. This patient was referred from a team of clinicians representing primary care, cardiology, gastroenterology, hematology, and psychology. Prior treatment had been unsuccessful in managing multiple chronic comorbidities. Diagnostic assessment included comprehensive stool and nutritional/metabolic laboratory testing. The blood-, urine-, or stool-based measurements of relevant markers for multiple systemic issues, including digestion/absorption, inflammation, oxidative stress, and methylation, identified previously unrecognized root causes of his constellation of symptoms. These functional measurements guided rational recommendations for dietary choices and supplementation. The patient experienced steady and significant improvement in his mental health, fatigue, chronic pain, and irritable bowel syndrome-as well as the unexpected resolution of his chronic idiopathic pancytopenia. The success in this case suggests that other patients with chronic, complex, and treatment-refractory illness may benefit from a system-oriented assessment of core imbalances guided by specialized nutritional/metabolic and digestive laboratory testing.

  7. Breast cancer: determining the genetic profile from ultrasound-guided percutaneous biopsy specimens obtained during the diagnostic workups.

    PubMed

    López Ruiz, J A; Zabalza Estévez, I; Mieza Arana, J A

    2016-01-01

    To evaluate the possibility of determining the genetic profile of primary malignant tumors of the breast from specimens obtained by ultrasound-guided percutaneous biopsies during the diagnostic imaging workup. This is a retrospective study in 13 consecutive patients diagnosed with invasive breast cancer by B-mode ultrasound-guided 12 G core needle biopsy. After clinical indication, the pathologist decided whether the paraffin block specimens seemed suitable (on the basis of tumor size, validity of the sample, and percentage of tumor cells) before sending them for genetic analysis with the MammaPrint® platform. The size of the tumors on ultrasound ranged from 0.6cm to 5cm. In 11 patients the preserved specimen was considered valid and suitable for use in determining the genetic profile. In 1 patient (with a 1cm tumor) the pathologist decided that it was necessary to repeat the core biopsy to obtain additional samples. In 1 patient (with a 5cm tumor) the specimen was not considered valid by the genetic laboratory. The percentage of tumor cells in the samples ranged from 60% to 70%. In 11/13 cases (84.62%) it was possible to do the genetic analysis on the previously diagnosed samples. In most cases, regardless of tumor size, it is possible to obtain the genetic profile from tissue specimens obtained with ultrasound-guided 12 G core biopsy preserved in paraffin blocks. Copyright © 2015 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  8. Real-Time 3D Fluoroscopy-Guided Large Core Needle Biopsy of Renal Masses: A Critical Early Evaluation According to the IDEAL Recommendations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kroeze, Stephanie G. C.; Huisman, Merel; Verkooijen, Helena M.

    2012-06-15

    Introduction: Three-dimensional (3D) real-time fluoroscopy cone beam CT is a promising new technique for image-guided biopsy of solid tumors. We evaluated the technical feasibility, diagnostic accuracy, and complications of this technique for guidance of large-core needle biopsy in patients with suspicious renal masses. Methods: Thirteen patients with 13 suspicious renal masses underwent large-core needle biopsy under 3D real-time fluoroscopy cone beam CT guidance. Imaging acquisition and subsequent 3D reconstruction was done by a mobile flat-panel detector (FD) C-arm system to plan the needle path. Large-core needle biopsies were taken by the interventional radiologist. Technical success, accuracy, and safety were evaluatedmore » according to the Innovation, Development, Exploration, Assessment, Long-term study (IDEAL) recommendations. Results: Median tumor size was 2.6 (range, 1.0-14.0) cm. In ten (77%) patients, the histological diagnosis corresponded to the imaging findings: five were malignancies, five benign lesions. Technical feasibility was 77% (10/13); in three patients biopsy results were inconclusive. The lesion size of these three patients was <2.5 cm. One patient developed a minor complication. Median follow-up was 16.0 (range, 6.4-19.8) months. Conclusions: 3D real-time fluoroscopy cone beam CT-guided biopsy of renal masses is feasible and safe. However, these first results suggest that diagnostic accuracy may be limited in patients with renal masses <2.5 cm.« less

  9. 3T MR-guided in-bore transperineal prostate biopsy: A comparison of robotic and manual needle-guidance templates.

    PubMed

    Tilak, Gaurie; Tuncali, Kemal; Song, Sang-Eun; Tokuda, Junichi; Olubiyi, Olutayo; Fennessy, Fiona; Fedorov, Andriy; Penzkofer, Tobias; Tempany, Clare; Hata, Nobuhiko

    2015-07-01

    To demonstrate the utility of a robotic needle-guidance template device as compared to a manual template for in-bore 3T transperineal magnetic resonance imaging (MRI)-guided prostate biopsy. This two-arm mixed retrospective-prospective study included 99 cases of targeted transperineal prostate biopsies. The biopsy needles were aimed at suspicious foci noted on multiparametric 3T MRI using manual template (historical control) as compared with a robotic template. The following data were obtained: the accuracy of average and closest needle placement to the focus, histologic yield, percentage of cancer volume in positive core samples, complication rate, and time to complete the procedure. In all, 56 cases were performed using the manual template and 43 cases were performed using the robotic template. The mean accuracy of the best needle placement attempt was higher in the robotic group (2.39 mm) than the manual group (3.71 mm, P < 0.027). The mean core procedure time was shorter in the robotic (90.82 min) than the manual group (100.63 min, P < 0.030). Percentage of cancer volume in positive core samples was higher in the robotic group (P < 0.001). Cancer yields and complication rates were not statistically different between the two subgroups (P = 0.557 and P = 0.172, respectively). The robotic needle-guidance template helps accurate placement of biopsy needles in MRI-guided core biopsy of prostate cancer. © 2014 Wiley Periodicals, Inc.

  10. Accuracy and effectiveness of ultrasound-guided core-needle biopsy in the diagnosis of focal lesions in the salivary glands.

    PubMed

    Del Cura, Jose Luis; Coronado, Gloria; Zabala, Rosa; Korta, Igone; López, Ignacio

    2018-01-31

    To review the diagnostic accuracy of ultrasound-guided core-needle biopsy (CNB) in the diagnosis of salivary gland tumours (SGT). Retrospective, institutional review board approved, analysis of the CNB of SGT performed at our centre in 8 years. We used an automatic 18-G spring-loaded device. The final diagnosis was based on surgery in the cases that were operated on, and on clinical evolution and biopsy findings in the rest. Four hundred and nine biopsies were performed in 381 patients (ages, 2-97 years; mean, 55.9). There were two minor complications. Biopsy was diagnostic in 98.3%. There were eight false negatives. The diagnostic values for malignancy were: sensitivity 89.6%, specificity 100%, positive predictive value (PPV) 100% and negative predictive value (NPV) 98%. For the detection of neoplasms were: sensitivity 98.7%, specificity 99%, PPV 99.7% and VPN 96.1%. Accuracy of CNB in SGT is very high, with a very high sensitivity and an absolutely reliable diagnosis of malignancy. Complication rate is very low. It should be considered the technique of choice when a STG is detected. Normal tissue results warrant repeating biopsy. • Ultrasound-guided core-biopsy is the technique of choice in salivary glands nodules • Sensitivity, specificity for detecting neoplasms (which should be resected) are around 99% • Diagnosis of malignancy in core-biopsy is absolutely reliable • A CNB result of "normal tissue", however, warrants repeating the biopsy • Complication rate is very low.

  11. CT-guided transgluteal biopsy for systematic sampling of the prostate in patients without rectal access: a 13-year single-center experience.

    PubMed

    Olson, Michael C; Atwell, Thomas D; Mynderse, Lance A; King, Bernard F; Welch, Timothy; Goenka, Ajit H

    2017-08-01

    The purpose of our study was to examine the safety and diagnostic utility of transgluteal CT-guided prostate biopsy for prostate sampling in patients without rectal access. Seventy-three biopsies were performed in 65 patients over a 13-year period (2002-2015). Mean prostate-specific antigen (PSA) at biopsy was 7.8 ng/mL (range 0.37-31.5). Electronic medical records were reviewed for procedural details and complications. Mean PSA and number of cores in malignant and benign cohorts were compared with Student's t test. Technical success rate was 97.3% (71/73; mean cores 8, range 3-28). Of these, 43.6% (31/71) yielded malignancy (mean Gleason score 7, range 6-10) and 56.3% (40/71) yielded benign tissue. The only complication was an asymptomatic periprostatic hematoma (1/73; 1.4%). In 14 patients who underwent surgery, Gleason scores were concordant in 71.4% (10/14) and discordant in 28.6% (4/14; Gleason 6 on biopsy but Gleason 7 on surgical specimen). Mean effective radiation dose was 18.5 mSv (median 15.0, range 4.4-86.2). There was no significant difference in either mean PSA (p = 0.06) or number of core specimens (p = 0.33) between malignant and benign cohorts. CT-guided transgluteal prostate biopsy is highly safe and reliable for the detection of prostate cancer in men without rectal access. • Prostate cancer detection in men without rectal access is challenging. • CT-guided transgluteal prostate biopsy is safe and effective in these patients. • CT-guided biopsy may be particularly effective in diagnosing high-grade prostate cancer. • Unilateral CT-guided biopsy may be effective in patients with focal lesions. • The radiation exposure with this technique is acceptable.

  12. Planar optical waveguides for optical panel having gradient refractive index core

    DOEpatents

    Veligdan, James T.

    2001-01-01

    An optical panel is disclosed. A plurality of stacked planar optical waveguides are used to guide light from an inlet face to an outlet face of an optical panel. Each of the optical waveguides comprises a planar sheet of core material having a central plane. The core material has an index of refraction which decreases as the distance from the central plane increases. The decrease in the index of refraction occurs gradually and continuously.

  13. Planar optical waveguides for optical panel having gradient refractive index core

    DOEpatents

    Veligdan, James T.

    2004-08-24

    An optical panel is disclosed. A plurality of stacked planar optical waveguides are used to guide light from an inlet face to an outlet face of an optical panel. Each of the optical waveguides comprises a planar sheet of core material having a central plane. The core material has an index of refraction which decreases as the distance from the central plane increases. The decrease in the index of refraction occurs gradually and continuously.

  14. Value of gallbladder B-scan ultrasonography.

    PubMed

    Tabrisky, J; Lindstrom, R R; Herman, M W; Castagna, J; Sarti, D

    1975-05-01

    The gallbladder B-scans of 20 patients who had subsequent surgery were separated into three categories based upon certain sonographic criteria. Our data, in this limited series, revealed gallbladder pathology in each patient who had any one or combination of the following scan characteristics: (1) internal echos, (2) irregular wall, or (3) absence of recognizable gallbladder sonolucency. The category which demonstrated a normal sonographic gallbladder, namely a smooth wall and no internal echos, contained a number of false negatives which proved to have either small stone cholelithiasis or extraphepatic ductal obstruction. Within the described limitations, the B-scan can be a valuable test in confirming the significance of a radiographically nonvisualized gallbladder or in detecting a biliary tract lesion in a patient with a disease entity that precludes radiographic visualization by conventional techniques.

  15. Sonographic study of the development of fetal corpus callosum in a Chinese population.

    PubMed

    Zhang, Hai-chun; Yang, Jie; Chen, Zhong-ping; Ma, Xiao-yan

    2009-02-01

    The observation of fetal corpus callosum (CC) is important for the prenatal sonographic assessment of fetal central nervous system development. The aim of this study was to investigate the development of normal Chinese fetal CC. CC measurements were performed using high-resolution transabdominal sonography on 622 Chinese fetuses between 16 and 39 weeks' gestation. The correlation between CC size and gestational age was investigated. The fetal CC length increased in a linear fashion during pregnancy. The length of the CC as a function of gestational age was expressed by the following regression equation: length (mm) = -9.567 + 1.495 x gestational age (weeks) (r = 0.932, p < 0.001). Knowledge of normal CC appearance may help identify developmental anomalies and enable accurate prenatal counseling. (c) 2008 Wiley Periodicals, Inc.

  16. Mammographic and sonographic findings of steatocystoma multiplex presenting as breast lumps.

    PubMed

    Wan, John Mun Chin; Wong, Jill Su Lin; Tee, Shang-Ian

    2012-12-01

    Steatocystoma multiplex (SM) is an uncommon cutaneous disorder characterised by multiple intradermal cysts distributed over the trunk and proximal extremities. This condition affects both genders and is often inherited as an autosomal dominant trait, although sporadic cases have been described. This report describes the mammographic and sonographic features of the cysts, which presented as breast lumps, for evaluation. The cysts appeared as numerous well-circumscribed, radiolucent nodules with thin radiodense rims on mammography. On sonography, the cysts could be hypoechoic, isoechoic or demonstrate mixed echoes containing debris-fluid levels, depending on the amount of clear oily liquid and keratinous material. SM can be diagnosed based on a clinical setting of multiple asymptomatic small intradermal nodules over the trunk and proximal extremities, positive family history and imaging findings.

  17. Novel splice techniques and micro-hole collapse effect in photonic crystal fibers

    NASA Astrophysics Data System (ADS)

    Xiao, Limin

    Photonic crystal fibers (PCFs) represent one of the most active research areas today in the field of fiber optics. Because of the freedom they offer in their design and novel wave-guiding properties, PCFs have resulted in a number of applications that are difficult to achieve with conventional fibers. In practical applications, low-loss connection PCFs with conventional fibers is a key issue for integrating PCF devices into existing fiber optic systems. However, connecting PCFs to conventional fibers without incurring too much loss is a very challenging problem. Two novel techniques were proposed to solve this problem in the thesis. One is fusion splicing technique; the other is micro-tip technique. First, fusion splicing technique for PCFs is investigated. For fusion splicing SMFs and PCFs having similar mode field diameters, a low-loss joint with good mechanical strength can be formed by choosing a suitably weak fusion current, short fusion time, offset and overlap to minimize the collapse of air holes and well melt two fibers together. For small-core PCFs, an optimum mode field match and an adiabatic mode field variation can be achieved by repeated arc discharges. Low-loss fusion splicing of five different PCFs with SMFs are achieved, including large mode PCF, hollow-core PCF, nonlinear PCFs with low and high air-filling fraction and polarization maintaining PCF. The other novel technique is using micro-tips. The method is based on growing photopolymer micro-tips directly on the end face of SMFs. The shape and the size of the tips can be controlled, by adjusting the laser power, the exposure time and the oxygen diffusion concentration for polymerization, to match its mode field to the small-core PCFs. Micro-hole collapse effect can be used to fabricate selective injection PCFs. The suitable arc discharge energy can cause the cladding holes to collapse while leaving the central hollow core to remain open. Thus a simple method for selective filling the central hole of PCFs is developed. Hybrid PCF guides light by a novel guiding mechanism, which is a combination of index-guiding and bandgap-guiding. The properties of the hybrid PCF are systematically investigated.

  18. Design of single-polarization wavelength splitter based on photonic crystal fiber.

    PubMed

    Zhang, Shanshan; Zhang, Weigang; Geng, Pengcheng; Li, Xiaolan; Ruan, Juan

    2011-12-20

    A new single-polarization wavelength splitter based on the photonic crystal fiber (PCF) has been proposed. The full-vector finite-element method (FEM) is applied to analyze the single-polarization single-mode guiding properties. Splitting of two different wavelengths is realized by adjusting the structural parameters. The semi-vector three-dimensional beam propagation method is employed to confirm the wavelength splitting characteristics of the PCF. Numerical simulations show that the wavelengths of 1.3 μm and 1.55 μm are split for a fiber length of 10.7 mm with single-polarization guiding in each core. The crosstalk between the two cores is low over appreciable optical bandwidths.

  19. Vaginal progesterone reduces the rate of preterm birth in women with a sonographic short cervix: a multicenter, randomized, double-blind, placebo-controlled trial

    PubMed Central

    HASSAN, S. S.; ROMERO, R.; VIDYADHARI, D.; FUSEY, S.; BAXTER, J. K.; KHANDELWAL, M.; VIJAYARAGHAVAN, J.; TRIVEDI, Y.; SOMA-PILLAY, P.; SAMBAREY, P.; DAYAL, A.; POTAPOV, V.; O’BRIEN, J.; ASTAKHOV, V.; YUZKO, O.; KINZLER, W.; DATTEL, B.; SEHDEV, H.; MAZHEIKA, L.; MANCHULENKO, D.; GERVASI, M. T.; SULLIVAN, L.; CONDE-AGUDELO, A.; PHILLIPS, J. A.; CREASY, G. W.

    2012-01-01

    Objectives Women with a sonographic short cervix in the mid-trimester are at increased risk for preterm delivery. This study was undertaken to determine the ef cacy and safety of using micronized vaginal progesterone gel to reduce the risk of preterm birth and associated neonatal complications in women with a sonographic short cervix. Methods This was a multicenter, randomized, double-blind, placebo-controlled trial that enrolled asymptomatic women with a singleton pregnancy and a sonographic short cervix (10–20 mm) at 19 + 0to23 + 6 weeks of gestation. Women were allocated randomly to receive vaginal progesterone gel or placebo daily starting from 20 to 23 + 6 weeks until 36 + 6 weeks, rupture of membranes or delivery, whichever occurred rst. Randomization sequence was strati ed by center and history of a previous preterm birth. The primary endpoint was preterm birth before 33 weeks of gestation. Analysis was by intention to treat. Results Of 465 women randomized, seven were lost to follow-up and 458 (vaginal progesterone gel, n = 235; placebo, n = 223) were included in the analysis. Women allocated to receive vaginal progesterone had a lower rate of preterm birth before 33 weeks than did those allocated to placebo (8.9% (n = 21) vs 16.1% (n = 36); relative risk (RR), 0.55; 95% CI, 0.33–0.92; P = 0.02). The effect remained signi cant after adjustment for covariables (adjusted RR, 0.52; 95% CI, 0.31–0.91; P = 0.02). Vaginal progesterone was also associated with a signi cant reduction in the rate of preterm birth before 28 weeks(5.1%vs10.3%; RR, 0.50;95%CI, 0.25–0.97; P = 0.04) and 35 weeks (14.5% vs 23.3%; RR, 0.62; 95% CI, 0.42–0.92; P = 0.02), respiratory distress syndrome (3.0% vs 7.6%; RR, 0.39; 95% CI, 0.17–0.92; P = 0.03), any neonatal morbidity or mortality event (7.7% vs 13.5%; RR, 0.57; 95% CI, 0.33–0.99; P = 0.04) and birth weight < 1500 g (6.4% (15/234) vs 13.6% (30/220); RR, 0.47; 95% CI, 0.26–0.85; P = 0.01). There were no differences in the incidence of treatment-related adverse events between the groups. Conclusions The administration of vaginal progesterone gel to women with a sonographic short cervix in the mid-trimester is associated with a 45% reduction in the rate of preterm birth before 33 weeks of gestation and with improved neonatal outcome. PMID:21472815

  20. Accurate cloud-based smart IMT measurement, its validation and stroke risk stratification in carotid ultrasound: A web-based point-of-care tool for multicenter clinical trial.

    PubMed

    Saba, Luca; Banchhor, Sumit K; Suri, Harman S; Londhe, Narendra D; Araki, Tadashi; Ikeda, Nobutaka; Viskovic, Klaudija; Shafique, Shoaib; Laird, John R; Gupta, Ajay; Nicolaides, Andrew; Suri, Jasjit S

    2016-08-01

    This study presents AtheroCloud™ - a novel cloud-based smart carotid intima-media thickness (cIMT) measurement tool using B-mode ultrasound for stroke/cardiovascular risk assessment and its stratification. This is an anytime-anywhere clinical tool for routine screening and multi-center clinical trials. In this pilot study, the physician can upload ultrasound scans in one of the following formats (DICOM, JPEG, BMP, PNG, GIF or TIFF) directly into the proprietary cloud of AtheroPoint from the local server of the physician's office. They can then run the intelligent and automated AtheroCloud™ cIMT measurements in point-of-care settings in less than five seconds per image, while saving the vascular reports in the cloud. We statistically benchmark AtheroCloud™ cIMT readings against sonographer (a registered vascular technologist) readings and manual measurements derived from the tracings of the radiologist. One hundred patients (75 M/25 F, mean age: 68±11 years), IRB approved, Toho University, Japan, consisted of Left/Right common carotid artery (CCA) artery (200 ultrasound scans), (Toshiba, Tokyo, Japan) were collected using a 7.5MHz transducer. The measured cIMTs for L/R carotid were as follows (in mm): (i) AtheroCloud™ (0.87±0.20, 0.77±0.20); (ii) sonographer (0.97±0.26, 0.89±0.29) and (iii) manual (0.90±0.20, 0.79±0.20), respectively. The coefficient of correlation (CC) between sonographer and manual for L/R cIMT was 0.74 (P<0.0001) and 0.65 (P<0.0001), while, between AtheroCloud™ and manual was 0.96 (P<0.0001) and 0.97 (P<0.0001), respectively. We observed that 91.15% of the population in AtheroCloud™ had a mean cIMT error less than 0.11mm compared to sonographer's 68.31%. The area under curve for receiving operating characteristics was 0.99 for AtheroCloud™ against 0.81 for sonographer. Our Framingham Risk Score stratified the population into three bins as follows: 39% in low-risk, 70.66% in medium-risk and 10.66% in high-risk bins. Statistical tests were performed to demonstrate consistency, reliability and accuracy of the results. The proposed AtheroCloud™ system is completely reliable, automated, fast (3-5 seconds depending upon the image size having an internet speed of 180Mbps), accurate, and an intelligent, web-based clinical tool for multi-center clinical trials and routine telemedicine clinical care. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. What Is Echocardiography?

    MedlinePlus

    ... EKG is a test that records the heart's electrical activity. A doctor or sonographer (a person specially ... this type of echo. TEE uses the same technology as transthoracic echo, but the transducer is attached ...

  2. Non-malignant breast papillary lesions - b3 diagnosed on ultrasound--guided 14-gauge needle core biopsy: analysis of 114 cases from a single institution and review of the literature.

    PubMed

    Bianchi, Simonetta; Bendinelli, Benedetta; Saladino, Valeria; Vezzosi, Vania; Brancato, Beniamino; Nori, Jacopo; Palli, Domenico

    2015-07-01

    One-hundred-fourteen consecutive cases of breast ultrasound-guided 14-gauge needle core biopsy (14G NCB) performed from January 2001 to June 2013 and diagnosed as non-malignant papillary lesion (PL)-B3, were reviewed and compared with definitive histological diagnosis on surgical excision (SE) to evaluate the diagnostic accuracy of ultrasound-guided 14G NCB. PL with epithelial atypia on 14G NCB were associated to malignancy on definitive histological diagnosis on SE in 22 (7 DCIS and 15 invasive carcinomas) of 46 cases with an underestimation rate of 47.8 %, while 9 (4 DCIS and 5 invasive carcinomas) cases out of 68 cases of PL without epithelial atypia were upgraded to carcinoma with an underestimation rate of 13.2 %. In cases of PL with epithelial atypia on ultrasound-guided 14G NCB, SE appears mandatory due to the high risk of associated malignancy. The diagnosis of PL without epithelial atypia on ultrasound-guided 14G NCB does not exclude malignancy at subsequent SE, consequently further assessment (by surgical or vacuum-assisted excision) is recommended to avoid the risk of delaying a diagnosis of malignancy, although this tends to be lower (1 in 8 patients).

  3. Automated tru-cut imaging-guided core needle biopsy of canine orbital neoplasia. A prospective feasibility study

    PubMed Central

    Cirla, A.; Rondena, M.; Bertolini, G.

    2016-01-01

    The purpose of this study was to evaluate the diagnostic value of imaging-guided core needle biopsy for canine orbital mass diagnosis. A second excisional biopsy obtained during surgery or necropsy was used as the reference standard. A prospective feasibility study was conducted in 23 canine orbital masses at a single centre. A complete ophthalmic examination was always followed by orbital ultrasound and computed tomography (CT) examination of the head. All masses were sampled with the patient still on the CT table using ultrasound (US) guided automatic tru-cut device. The most suitable sampling approach to the orbit was chosen each time based on the CT image analysis. One of the following different approaches was used: trans-orbital, trans-conjunctival or trans-masseteric. In all cases, the imaging-guided biopsy provided a sufficient amount of tissue for the histopathological diagnosis, which concurred with the biopsies obtained using the excisional technique. CT examination was essential for morphological diagnosis and provided detailed topographic information that allowed us to choose the safest orbital approach for the biopsy. US guided automatic tru-cut biopsy based on CT images, performed with patient still on the CT table, resulted in a minimally invasive, relatively easy, and accurate diagnostic procedure in dogs with orbital masses. PMID:27540512

  4. Automated tru-cut imaging-guided core needle biopsy of canine orbital neoplasia. A prospective feasibility study.

    PubMed

    Cirla, A; Rondena, M; Bertolini, G

    2016-01-01

    The purpose of this study was to evaluate the diagnostic value of imaging-guided core needle biopsy for canine orbital mass diagnosis. A second excisional biopsy obtained during surgery or necropsy was used as the reference standard. A prospective feasibility study was conducted in 23 canine orbital masses at a single centre. A complete ophthalmic examination was always followed by orbital ultrasound and computed tomography (CT) examination of the head. All masses were sampled with the patient still on the CT table using ultrasound (US) guided automatic tru-cut device. The most suitable sampling approach to the orbit was chosen each time based on the CT image analysis. One of the following different approaches was used: trans-orbital, trans-conjunctival or trans-masseteric. In all cases, the imaging-guided biopsy provided a sufficient amount of tissue for the histopathological diagnosis, which concurred with the biopsies obtained using the excisional technique. CT examination was essential for morphological diagnosis and provided detailed topographic information that allowed us to choose the safest orbital approach for the biopsy. US guided automatic tru-cut biopsy based on CT images, performed with patient still on the CT table, resulted in a minimally invasive, relatively easy, and accurate diagnostic procedure in dogs with orbital masses.

  5. Modern sedimentary environments in a large tidal estuary, Delaware Bay

    USGS Publications Warehouse

    Knebel, H.J.

    1989-01-01

    Data from an extensive grid of sidescan-sonar records reveal the distribution of sedimentary environments in the large, tidally dominated Delaware Bay estuary. Bathymetric features of the estuary include large tidal channels under the relatively deep (> 10 m water depth) central part of the bay, linear sand shoals (2-8 m relief) that parallel the sides of the tidal channels, and broad, low-relief plains that form the shallow bay margins. The two sedimentary environments that were identified are characterized by either (1) bedload transport and/or erosion or (2) sediment reworking and/or deposition. Sand waves and sand ribbons, composed of medium to coarse sands, define sites of active bedload transport within the tidal channels and in gaps between the linear shoals. The sand waves have spacings that vary from 1 to 70 m, amplitudes of 2 m or less, and crestlines that are usually straight. The orientations of the sand waves and ribbons indicate that bottom sediment movement may be toward either the northwest or southeast along the trends of the tidal channels, although sand-wave asymmetry indicates that the net bottom transport is directed northwestward toward the head of the bay. Gravelly, coarse-grained sediments, which appear as strongly reflective patterns on the sonographs, are also present along the axes and flanks of the tidal channels. These coarse sediments are lag deposits that have developed primarily where older strata were eroded at the bay floor. Conversely, fine sands that compose the linear shoals and muddy sands that cover the shallow bay margins appear mainly on the sonographs either as smooth featureless beds that have uniform light to moderate shading or as mosaics of light and dark patches produced by variations in grain size. These acoustic and textural characteristics are the result of sediment deposition and reworking. Data from this study (1) support the hypothesis that bed configurations under deep tidal flows are functions of current velocity, sediment size, and depth; (2) suggest criteria that could be used to distinguish between open estuarine tidal deposits in the geologic record; and (3) provide a guide to future utilization of the bay floor. ?? 1989.

  6. America's Role in the Middle East. Public Talk Series.

    ERIC Educational Resources Information Center

    McCoy, Martha

    This program guide encourages discussion on what role the United States should pursue in the Middle East. The guide is designed to assist in the discussion of critical social and political issues through a balanced, nonpartisan presentation of a spectrum of views. The core of the program considers four underlying goals: (1) the United States as…

  7. Selective Guide to Literature on Mining Engineering. Engineering Literature Guides, Number 6.

    ERIC Educational Resources Information Center

    Erdmann, Charlotte A., Comp.

    The multidisciplinary field of mining engineering offers many challenges. Often, many sources must be used to solve a problem. This document is a survey of information sources in mining engineering and is intended to identify those core resources which can help engineers and librarians to find information about the discipline. Sections include:…

  8. Cognitive Behavioral Guided Self-Help for the Treatment of Recurrent Binge Eating

    ERIC Educational Resources Information Center

    Striegel-Moore, Ruth H.; Wilson, G. Terence; DeBar, Lynn; Perrin, Nancy; Lynch, Frances; Rosselli, Francine; Kraemer, Helena C.

    2010-01-01

    Objective: Despite proven efficacy of cognitive behavioral therapy (CBT) for treating eating disorders with binge eating as the core symptom, few patients receive CBT in clinical practice. Our blended efficacy-effectiveness study sought to evaluate whether a manual-based guided self-help form of CBT (CBT-GSH), delivered in 8 sessions in a health…

  9. Safe and Sound: An Educational Leader's Guide to Evidence-Based Social and Emotional Learning (SEL) Programs

    ERIC Educational Resources Information Center

    Collaborative for Academic, Social, and Emotional Learning (NJ1), 2003

    2003-01-01

    This guide was developed to provide educators with information about nationally available programs for the classroom that promote social and emotional learning (SEL). It details the costs, the grades covered, evidence base, which most effectively teach core social and emotional skills, and which provide high-quality staff development and support.…

  10. Advanced Marketing. Marketing Education Teacher's Resource Guide. Expected Student Learning Outcomes and Cross-Referenced Instructional Materials by Competencies.

    ERIC Educational Resources Information Center

    Smith, Clifton L.

    This guide, developed by a project to revise the minimum core competencies for the advanced marketing course in secondary marketing education in Missouri, contains four sections. The first section explains competency-based marketing education, including its mission, nature, curriculum, and the fundamentals of competency-based instruction. The…

  11. Fundamentals of Marketing. Marketing Education Teacher's Resource Guide. Expected Student Learning Outcomes and Cross-Referenced Instructional Materials by Competencies.

    ERIC Educational Resources Information Center

    Smith, Clifton L.

    This guide, developed by a project to revise the minimum core competencies for the Fundamentals of Marketing course in secondary marketing education in Missouri, contains four sections. The first section explains competency-based marketing education, including its mission, nature, curriculum, and the fundamentals of competency-based instruction.…

  12. Predictors of underestimation of malignancy after image-guided core needle biopsy diagnosis of flat epithelial atypia or atypical ductal hyperplasia.

    PubMed

    Yu, Chi-Chang; Ueng, Shir-Hwa; Cheung, Yun-Chung; Shen, Shih-Che; Kuo, Wen-Lin; Tsai, Hsiu-Pei; Lo, Yung-Feng; Chen, Shin-Cheh

    2015-01-01

    Flat epithelial atypia (FEA) and atypical ductal hyperplasia (ADH) are precursors of breast malignancy. Management of FEA or ADH after image-guided core needle biopsy (CNB) remains controversial. The aim of this study was to evaluate malignancy underestimation rates after FEA or ADH diagnosis using image-guided CNB and to identify clinical characteristics and imaging features associated with malignancy as well as identify cases with low underestimation rates that may be treatable by observation only. We retrospectively reviewed 2,875 consecutive image-guided CNBs recorded in an electronic data base from January 2010 to December 2011 and identified 128 (4.5%) FEA and 83 (2.9%) ADH diagnoses (211 total cases). Of these, 64 (30.3%) were echo-guided CNB procedures and 147 (69.7%) mammography-guided CNBs. Twenty patients (9.5%) were upgraded to malignancy. Multivariate analysis indicated that age (OR = 1.123, p = 0.002, increase of 1 year), mass-type lesion with calcifications (OR = 8.213, p = 0.006), and ADH in CNB specimens (OR = 8.071, p = 0.003) were independent predictors of underestimation. In univariate analysis of echo-guided CNB (n = 64), mass with calcifications had the highest underestimation rate (p < 0.001). Multivariate analysis of 147 mammography-guided CNBs revealed that age (OR = 1.122, p = 0.040, increase of 1 year) and calcification distribution were significant independent predictors of underestimation. No FEA case in which, complete calcification retrieval was recorded after CNB was upgraded to malignancy. Older age at diagnosis on image-guided CNB was a predictor of malignancy underestimation. Mass with calcifications was more likely to be associated with malignancy, and in cases presenting as calcifications only, segmental distribution or linear shapes were significantly associated with upgrading. Excision after FEA or ADH diagnosis by image-guided CNB is warranted except for FEA diagnosed using mammography-guided CNB with complete calcification retrieval. © 2015 Wiley Periodicals, Inc.

  13. Core II Materials for Rural Agriculture Programs. Units E-H.

    ERIC Educational Resources Information Center

    Biondo, Ron; And Others

    This curriculum guide includes teaching packets for 21 problem areas to be included in a core curriculum for 10th grade students enrolled in a rural agricultural program. Covered in the four units included in this volume are crop science (harvesting farm crops and growing small grains); soil science and conservation of natural resources…

  14. Bricklaying Curriculum: Basic Core. Instructional Materials. Revised.

    ERIC Educational Resources Information Center

    Turcotte, Raymond J.; Hendrix, Laborn J.

    This volume, the first in a two-volume core curriculum, is designed for use in teaching a course in basic bricklaying. Included in the introductory section of the guide are units on the free enterprise system, the economics of free enterprise, industry orientation, ways of becoming a good leader, job advancement, and safety and first aid. The next…

  15. Forum Guide to Supporting Data Access for Researchers: A State Education Agency Perspective. NFES 2012-809

    ERIC Educational Resources Information Center

    National Forum on Education Statistics, 2012

    2012-01-01

    This document recommends a set of "core" practices, operations, and templates that can be adopted and adapted by state education agencies (SEAs) as they consider how to respond to requests for data about the education enterprise, including data maintained in longitudinal data systems. These recommendations reflect core practices and…

  16. Core III Materials for Metropolitan Agriculture/Horticulture Programs. Units A-I.

    ERIC Educational Resources Information Center

    Biondo, Ron; And Others

    This first volume of a two-volume curriculum guide contains 11 problem areas selected for study to be included in a core curriculum for 11th-grade or third-year students enrolled in a metropolitan agricultural program. The 11 problem areas are divided into eight units: Orientation to Agricultural Occupations (Gaining Employment), Supervised…

  17. What Teachers Should Know about Common Core: A Guide for the Perplexed

    ERIC Educational Resources Information Center

    Shanahan, Timothy

    2015-01-01

    In 2010, more than 40 states adopted the Common Core State Standards. Initially, the standards were quickly and easily embraced, but over the past year the standards have become enmeshed in various controversies, raising many questions about how the standards were written and what they include. This article attempts to provide authoritative…

  18. Core IV Materials for Rural Agriculture Programs. Units H-I.

    ERIC Educational Resources Information Center

    Courson, Roger; And Others

    This curriculum guide, the second part of a core curriculum for a rural agriculture program, consists of materials for use in presenting the final two units in a nine-unit course for high school vocational agriculture students living in rural areas. Addressed in the first unit are the following aspects of agricultural mechanics: selecting and…

  19. Horticulture Materials for Agricultural Education Programs. Core Agricultural Education Curriculum, Central Cluster.

    ERIC Educational Resources Information Center

    Illinois Univ., Urbana. Office of Agricultural Communications and Education.

    This curriculum guide contains five units with relevant problem areas for horticulture. These problem areas have been selected as suggested areas of study to be included in a core curriculum for secondary students enrolled in an agricultural education program. Each problem area includes some or all of the following components: related problem…

  20. Selecting and Using a Core-Reference Collection. Second Edition.

    ERIC Educational Resources Information Center

    Nichols, Margaret Irby

    Core-reference collections are the small number of sources which meet the basic needs of all libraries, and the purpose of this guide is to assist libraries in the selection, acquisition, and use of these resources. Section I, structured like an annotated bibliography, focuses on the selection of those works which should constitute the main…

  1. Realizing A Mid-Infrared Optically Pumped Molecular Gas Laser Inside Hollow-Core Photonic Crystal Fiber

    DTIC Science & Technology

    2012-01-01

    54  Figure 5.2 External transmission of (a) BK7 glass , (b) CaF2, and (c) Germanium substrates of various thicknesses. The transmission values...a hollow, air-filled core surrounded by cladding structure which is comprised of a periodic array of smaller air holes. Unlike glass capillaries...region of the fiber’s core. The low overlap of the guided light with the HC-PCF’s glass structure together with a higher threshold for the onset of

  2. Concordance of Gleason grading with three-dimensional ultrasound systematic biopsy and biopsy core pre-embedding.

    PubMed

    van der Aa, Anouk A M A; Mannaerts, Christophe K; van der Linden, Hans; Gayet, Maudy; Schrier, Bart Ph; Mischi, Massimo; Beerlage, Harrie P; Wijkstra, Hessel

    2018-02-01

    To determine the value of a three-dimensional (3D) greyscale transrectal ultrasound (TRUS)-guided prostate biopsy system and biopsy core pre-embedding method on concordance between Gleason scores of needle biopsies and radical prostatectomy (RP) specimens. Retrospective analysis of prostate biopsies and subsequent RP for PCa in the Jeroen Bosch Hospital, the Netherlands, from 2007 to 2016. Two cohorts were analysed: conventional 2D TRUS-guided biopsies and RP (2007-2013, n = 266) versus 3D TRUS-guided biopsies with pre-embedding (2013-2016, n = 129). The impact of 3D TRUS-guidance with pre-embedding on Gleason score (GS) concordance between biopsy and RP was evaluated using the κ-coefficient. Predictors of biopsy GS 6 upgrading were assessed using logistic regression models. Gleason concordance was comparable between the two cohorts with a κ = 0.44 for the 3D cohort, compared to κ = 0.42 for the 2D cohort. 3D TRUS-guidance with pre-embedding, did not significantly affect the risk of biopsy GS 6 upgrading in univariate and multivariate analysis. 3D TRUS-guidance with biopsy core pre-embedding did not improve Gleason concordance. Improved detection techniques are needed for recognition of low-grade disease upgrading.

  3. Numerical study of core formation of asymmetrically driven cone-guided targets

    DOE PAGES

    Sawada, Hiroshi; Sakagami, Hitoshi

    2017-09-22

    Compression of a directly driven fast ignition cone-sphere target with a finite number of laser beams is numerically studied using a three-dimensional hydrodynamics code IMPACT-3D. The formation of a dense plasma core is simulated for 12-, 9-, 6-, and 4-beam configurations of the GEKKO XII laser. The complex 3D shapes of the cores are analyzed by elucidating synthetic 2D x-ray radiographic images in two orthogonal directions. Finally, the simulated x-ray images show significant differences in the core shape between the two viewing directions and rotation of the stagnating core axis in the top view for the axisymmetric 9- and 6-beammore » configurations.« less

  4. Numerical study of core formation of asymmetrically driven cone-guided targets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sawada, Hiroshi; Sakagami, Hitoshi

    Compression of a directly driven fast ignition cone-sphere target with a finite number of laser beams is numerically studied using a three-dimensional hydrodynamics code IMPACT-3D. The formation of a dense plasma core is simulated for 12-, 9-, 6-, and 4-beam configurations of the GEKKO XII laser. The complex 3D shapes of the cores are analyzed by elucidating synthetic 2D x-ray radiographic images in two orthogonal directions. Finally, the simulated x-ray images show significant differences in the core shape between the two viewing directions and rotation of the stagnating core axis in the top view for the axisymmetric 9- and 6-beammore » configurations.« less

  5. Stiffness at shear-wave elastography and patient presentation predicts upgrade at surgery following an ultrasound-guided core biopsy diagnosis of ductal carcinoma in situ.

    PubMed

    Evans, A; Purdie, C A; Jordan, L; Macaskill, E J; Flynn, J; Vinnicombe, S

    2016-11-01

    The aim of this study is to establish predictors of invasion in lesions yielding an ultrasound-guided biopsy diagnosis of ductal carcinoma in situ (DCIS). Patients subjected to ultrasound-guided core biopsy yielding DCIS were studied. At shear-wave elastography (SWE) a threshold of 50 kPa was used for mean elasticity (Emean) to dichotomise the elasticity data between invasive and non-invasive masses. Data recorded included the mammographic and ultrasound features, the referral source, and grade of DCIS in the biopsy. The chi-square test was used to detect statistical significance. Of 57 lesions, 24 (42%) had invasion at excision. Symptomatic patients and patients with stiff lesions were more likely to have invasion than patients presenting through screening and with soft lesions (58% [14 of 24] versus 30% [10 of 33], p=0.03) and (51% [20 of 39] versus 22% [4 of 18], p=0.04). No other factors showed a relationship with invasion. Combining the two predictors of invasion improved risk stratification with symptomatic and stiff lesions having a risk of invasion of 67% (12 of 18) and soft lesions presenting at screening having only a 17% (2 of 12) risk of invasion (p=0.02). Stiffness on SWE and the referral source of the patient are predictors of occult invasion in women with an ultrasound-guided core biopsy diagnosis of DCIS. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  6. Intrapartum sonographic imaging of fetal head asynclitism.

    PubMed

    Ghi, T; Youssef, A; Pilu, G; Malvasi, A; Ragusa, A

    2012-02-01

    Anterior asynclitism was suspected on digital examination of a laboring woman with late arrest of dilatation and no evidence of fetal head progression. Clinical examination revealed a fixed non-engaged fetal head (station −1), with a transverse posterior sagittal suture. A static three-dimensional volume was obtained by translabial ultrasound, offline analysis of which confirmed the clinical diagnosis of anterior asynclitism. Owing to the posterior twisting of the head towards the sacrum, the midline echo could only be obtained by cutting the volume with an oblique line, the direction of which was not perpendicular to the pubis as expected in cases of synclitic head. The sonographic appearance of the midline echo approaching the sacrum in a non-engaged transverse fetal head strongly supports the clinical suspicion of anterior asynclitism. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.

  7. Sonographic anatomy of the gastrohepatic ligament.

    PubMed

    Desai, Gaurav; Filly, Roy A

    2010-01-01

    The purpose of this presentation is to illustrate anatomic and pathologic features of the gastrohepatic ligament (GHL) and to show its usefulness for precise localization of abnormalities, particularly in relation to the lesser peritoneal cavity and diseases occurring within the confines of the ligament itself. Cases were selected that illustrate the objectives above. Illustrations show various anatomic and pathologic features meant to enhance interpretation of left upper quadrant sonograms. Illustrations seen in the sonographic literature vaguely interpret the relationships of the GHL. Misunderstanding has led not only to improper nomenclature but also to the use of inappropriate indicators of lesser omental diseases. With a clear understanding of the anatomy of the GHL and its use as a pivotal marker for structures around and within it, one can avoid these pitfalls and better evaluate adult and pediatric lesser omental anatomy.

  8. Imaging the fetal central nervous system

    PubMed Central

    De Keersmaecker, B.; Claus, F.; De Catte, L.

    2011-01-01

    The low prevalence of fetal central nervous system anomalies results in a restricted level of exposure and limited experience for most of the obstetricians involved in prenatal ultrasound. Sonographic guidelines for screening the fetal brain in a systematic way will probably increase the detection rate and enhance a correct referral to a tertiary care center, offering the patient a multidisciplinary approach of the condition. This paper aims to elaborate on prenatal sonographic and magnetic resonance imaging (MRI) diagnosis and outcome of various central nervous system malformations. Detailed neurosonographic investigation has become available through high resolution vaginal ultrasound probes and the development of a variety of 3D ultrasound modalities e.g. ultrasound tomographic imaging. In addition, fetal MRI is particularly helpful in the detection of gyration and neurulation anomalies and disorders of the gray and white matter. PMID:24753859

  9. The value of homemade phantoms for training veterinary students in the ultrasonographic detection of radiolucent foreign bodies.

    PubMed

    Mariano Beraldo, Carolina; Rondon Lopes, Érika; Hage, Raduan; Hage, Maria Cristina F N S

    2017-03-01

    Ingested or penetrating foreign bodies are common in veterinary medicine. When they are radiolucent, these objects become a diagnostic challenge, but they can be investigated sonographically. However, successful object identification depends on the skill of the sonographer. Considering that these cases appear randomly during hospital routines, it is not always possible to train all students to identify them correctly. Therefore, the aim of this study was to produce homemade simulations of radiolucent foreign bodies for veterinary student demonstrations that could be identified sonographically and to evaluate the acceptability, applicability, and usefulness of these simulations according to a visual analog scale questionnaire and subjective questions. For this purpose, object models (a pacifier nipple, a toy ball, a sock, nylon thread, and a mango seed) were designed, produced, and immersed in gelatin. To simulate wood splinters in the integumentary and musculoskeletal system, a piece of meat punctured with a toothpick and ice cream stick splinters were used. The type of phantom had a determinant effect on the visualization (chi-square = 36.528, P < 0.0001) and recognition (chi-square = 18.756, P = 0.0021) capability of the students. All of the students answered that their experience with the models could help in real situations. The student responses to the questionnaire indicated that the project was well accepted, and the participants believed that this experience could be applicable to and useful in veterinary routines. Copyright © 2017 the American Physiological Society.

  10. Prediction of maximal surface electromyographically based voluntary contractions of erector spinae muscles from sonographic measurements during isometric contractions.

    PubMed

    Cuesta-Vargas, Antonio I; González-Sánchez, Manuel

    2014-03-01

    Currently, there are no studies combining electromyography (EMG) and sonography to estimate the absolute and relative strength values of erector spinae (ES) muscles in healthy individuals. The purpose of this study was to establish whether the maximum voluntary contraction (MVC) of the ES during isometric contractions could be predicted from the changes in surface EMG as well as in fiber pennation and thickness as measured by sonography. Thirty healthy adults performed 3 isometric extensions at 45° from the vertical to calculate the MVC force. Contractions at 33% and 100% of the MVC force were then used during sonographic and EMG recordings. These measurements were used to observe the architecture and function of the muscles during contraction. Statistical analysis was performed using bivariate regression and regression equations. The slope for each regression equation was statistically significant (P < .001) with R(2) values of 0.837 and 0.986 for the right and left ES, respectively. The standard error estimate between the sonographic measurements and the regression-estimated pennation angles for the right and left ES were 0.10 and 0.02, respectively. Erector spinae muscle activation can be predicted from the changes in fiber pennation during isometric contractions at 33% and 100% of the MVC force. These findings could be essential for developing a regression equation that could estimate the level of muscle activation from changes in the muscle architecture.

  11. Diagnosis of neonatal ovarian torsion: Emphasis on prenatal and postnatal sonographic findings.

    PubMed

    Kim, Hyun Su; Yoo, So-Young; Cha, Min Jae; Kim, Ji Hye; Jeon, Tae Yeon; Kim, Wee Kyoung

    2016-06-01

    Our aim was to retrospectively review the imaging findings of patients with neonatal ovarian torsion, emphasizing prenatal and postnatal sonographic findings. Eleven patients who had had neonatal ovarian torsion diagnosed surgically (n = 9) or clinicoradiologically (n = 2) were enrolled. Prenatal and postnatal sonographic features, including sequential postnatal change, were reviewed. Clinical and pathologic features were also investigated. All patients except one had a fetal ovarian cyst (mean, 5.3 cm) detected on third-trimester sonography, either simple (n = 6) or complex (n = 4). In all 11 patients, initial postnatal sonography had revealed a complex cyst (mean, 4.7 cm) with intracystic clot or debris, the double-wall sign, a fluid-fluid level, and multiple septation. None of the patients had had symptoms or signs related to the ovarian torsion. Follow-up sonography in seven patients had revealed increased echogenicity of the cyst wall with frequent calcification and a decrease in size of the cyst. In two patients, the interval of the change in cyst position was noted, and autoamputation of the torsed ovary had been surgically confirmed. Serous cystadenoma had been identified in one patient. Neonatal ovarian torsion most commonly manifests as an asymptomatic complex cyst on sonography due to torsion of a fetal ovarian cyst. Serial monitoring of a fetal ovarian cyst for its resolution or changes in its appearance is mandatory for making an early diagnosis of torsion. © 2016 Wiley Periodicals, Inc. J Clin Ultrasound 44:290-297, 2016. © 2016 Wiley Periodicals, Inc.

  12. Visualization of the inferoposterior thoracic wall (VIP) and boomerang signs-novel sonographic signs of right pleural effusion.

    PubMed

    Lau, James Siu Ki; Yuen, Chi Kit; Mok, Ka Leung; Yan, Wing Wa; Kan, Pui Gay

    2017-11-15

    This study is to present the diagnostic values of the novel sonographic visualization of the inferoposterior thoracic wall (VIP) and boomerang signs in detecting right pleural effusion by sonologists with little to no experience in ultrasound. A prospective analysis of a convenience sample of patients who were assessed by junior intensive care physicians was performed. The patients all underwent computed tomography (CT) of the chest or abdomen with lung bases as part of their care regardless of indication; the results were interpreted by radiologists and were considered the gold standard. Sonography was performed to assess for the presence of the VIP and boomerang signs. Sonographic and chest radiographic findings were compared against CT results. 73 patients were enrolled. The sensitivity and specificity for the VIP sign were 0.85 (95% confidence interval [CI], 0.67-0.94) and 0.86 (95% CI, 0.70-0.95). The sensitivity and specificity for the boomerang sign were 0.78 (95% CI, 0.60-0.90) and 0.87 (95% CI, 0.71-0.95). However, the sensitivity and specificity for the traditional approach of detecting an anechoic collection above the diaphragm to indicate pleural effusion were only 0.54 (95% CI, 0.37-0.71) and 0.86 (95% CI, 0.80-0.99). Despite inexperience in sonography, the novel VIP and boomerang signs show high diagnostic values in detecting right pleural effusion compared to the traditional methods. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Contrast-enhanced sonography for quantitative assessment of portal hypertension in patients with liver cirrhosis.

    PubMed

    Qu, En-Ze; Zhang, Ying-Cai; Li, Zhi-Yan; Liu, Yang; Wang, Jin-Rui

    2014-11-01

    The clinical utility of contrast-enhanced sonography in portal hypertension remains unclear. We explored the feasibility of using contrast-enhanced sonography for noninvasive assessment of portal venous pressure. Twenty healthy individuals (control group; 9 men; mean age, 46.4 years) and 18 patients with portal hypertension (15 men; mean age, 46.2 years) were enrolled in this study. The portal hypertension group included patients who underwent splenectomy and pericardial blood vessel disarticulation at our hospital from October 2010 to March 2011. One week before surgery, patients with portal hypertension underwent preoperative liver contrast-enhanced sonography. Two-dimensional, Doppler, and contrast-enhanced sonographic parameters were compared between the groups. Portal venous pressure was measured intraoperatively by portal vein puncture in the portal hypertension group, and its relationship with the other parameters was analyzed. The 2-dimensional, Doppler, and contrast-enhanced sonographic parameters differed between the groups (P < .01). Portal venous pressure was inversely correlated with the area under the portal vein/hepatic artery time-intensity curve ratio (Qp/Qa), portal vein/hepatic artery strength ratio (Ip/Ia), and portal vein/hepatic artery wash-in perfusion slope ratio (βp/βa), with correlation coefficients of -0.701, -0.625, and -0.494, respectively. Measurement of the liver contrast-enhanced sonographic parameters Qp/Qa, Ip/Ia, and βp/βa could be used as a new quantitative method for noninvasively assessing portal venous pressure. © 2014 by the American Institute of Ultrasound in Medicine.

  14. VAGINAL PROGESTERONE IN WOMEN WITH AN ASYMPTOMATIC SONOGRAPHIC SHORT CERVIX IN THE MIDTRIMESTER DECREASES PRETERM DELIVERY AND NEONATAL MORBIDITY: A SYSTEMATIC REVIEW AND META-ANALYSIS OF INDIVIDUAL PATIENT DATA

    PubMed Central

    ROMERO, Roberto; NICOLAIDES, Kypros; CONDE-AGUDELO, Agustin; TABOR, Ann; O’BRIEN, John M.; CETINGOZ, Elcin; DA FONSECA, Eduardo; CREASY, George; KLEIN, Katharina; RODE, Line; SOMA-PILLAY, Priya; FUSEY, Shalini; CAM, Cetin; ALFIREVIC, Zarko; HASSAN, Sonia S.

    2012-01-01

    OBJECTIVE To determine whether the use of vaginal progesterone in asymptomatic women with a sonographic short cervix in the mid-trimester reduces the risk of preterm birth and improves neonatal morbidity and mortality. STUDY DESIGN Individual patient data meta-analysis of randomized controlled trials. RESULTS Five trials of high quality were included with a total of 775 women and 827 infants. Treatment with vaginal progesterone was associated with a significant reduction in the rate of preterm birth <33 weeks (RR 0.58, 95% CI 0.42–0.80), <35 weeks (RR 0.69, 95% CI 0.55–0.88) and <28 weeks (RR 0.50, 95% CI 0.30–0.81), respiratory distress syndrome (RR 0.48, 95% CI 0.30–0.76), composite neonatal morbidity and mortality (RR 0.57, 95% CI 0.40–0.81), birth weight <1500 g (RR 0.55, 95% CI 0.38–0.80), admission to NICU (RR 0.75, 95% CI 0.59–0.94), and requirement for mechanical ventilation (RR 0.66, 95% CI 0.44–0.98). There were no significant differences between the vaginal progesterone and placebo groups in the rate of adverse maternal events or congenital anomalies. CONCLUSION Vaginal progesterone administration to asymptomatic women with a sonographic short cervix reduces the risk of preterm birth and neonatal morbidity and mortality. PMID:22284156

  15. Interference fringes on GLORIA side-scan sonar images from the Bering Sea and their implications

    USGS Publications Warehouse

    Huggett, Q.J.; Cooper, A. K.; Somers, M.L.; Stubbs, A.R.

    1992-01-01

    GLORIA side-scan sonographs from the Bering Sea Basin show a complex pattern of interference fringes sub-parallel to the ship's track. Surveys along the same trackline made in 1986 and 1987 show nearly identical patterns. It is concluded from this that the interference patterns are caused by features in the shallow subsurface rather than in the water column. The fringes are interpreted as a thin-layer interference effect that occurs when some of the sound reaching the seafloor passes through it and is reflected off a subsurface layer. The backscattered sound interferes (constructively or desctructively) with the reflected sound. Constructive/destructive interference occurs when the difference in the length of the two soundpaths is a whole/half multiple of GLORIA's 25 cm wavelength. Thus as range from the ship increases, sound moves in and out of phase causing bands of greater and lesser intensity on the GLORIA sonograph. Fluctuations (or 'wiggles') of the fringes on the GLORIA sonographs relate to changes in layer thickness. In principle, a simple three dimensional image of the subsurface layer may be obtained using GLORIA and bathymetric data from adjacent (parallel) ship's tracks. These patterns have also been identified in images from two other systems; SeaMARC II (12 kHz) long-range sonar, and TOBI (30 kHz) deep-towed sonar. In these, and other cases world-wide, the fringes do not appear with the same persistence as those seen in the Bering Sea. ?? 1992 Kluwer Academic Publishers.

  16. Designing Tracking Software for Image-Guided Surgery Applications: IGSTK Experience

    PubMed Central

    Enquobahrie, Andinet; Gobbi, David; Turek, Matt; Cheng, Patrick; Yaniv, Ziv; Lindseth, Frank; Cleary, Kevin

    2009-01-01

    Objective Many image-guided surgery applications require tracking devices as part of their core functionality. The Image-Guided Surgery Toolkit (IGSTK) was designed and developed to interface tracking devices with software applications incorporating medical images. Methods IGSTK was designed as an open source C++ library that provides the basic components needed for fast prototyping and development of image-guided surgery applications. This library follows a component-based architecture with several components designed for specific sets of image-guided surgery functions. At the core of the toolkit is the tracker component that handles communication between a control computer and navigation device to gather pose measurements of surgical instruments present in the surgical scene. The representations of the tracked instruments are superimposed on anatomical images to provide visual feedback to the clinician during surgical procedures. Results The initial version of the IGSTK toolkit has been released in the public domain and several trackers are supported. The toolkit and related information are available at www.igstk.org. Conclusion With the increased popularity of minimally invasive procedures in health care, several tracking devices have been developed for medical applications. Designing and implementing high-quality and safe software to handle these different types of trackers in a common framework is a challenging task. It requires establishing key software design principles that emphasize abstraction, extensibility, reusability, fault-tolerance, and portability. IGSTK is an open source library that satisfies these needs for the image-guided surgery community. PMID:20037671

  17. How High Is It? An Educator's Guide with Activities Focused on Scale Models of Distances.

    ERIC Educational Resources Information Center

    Rosenberg, Carla B.; Rogers, Melissa J. B.

    This guide focuses on scale models of distances. Activities also incorporate mathematics but can be used in science and technology grades 5-8 classes. The content of the book is divided into three sections: (1) Introductory Activities; (2) Core Activities; and (3) Activity/Assessment. Activities include: (1) KWL Chart; (2) Ball and String…

  18. Entomology for Agricultural Science II Core Curriculum. Instructor Guide, Volume 23, Number 2, and Student Reference, Volume 23, Number 3.

    ERIC Educational Resources Information Center

    DeFelice, Karen L.

    This unit is a basic introduction to entomology. The instructor guide and the corresponding student reference contain seven lessons: (1) introduction to entomology; (2) insect collection; (3) insect identification; (4) methods of control; (5) chemical control measures; (6) safe use of insecticides; and (7) integrated pest management. Students…

  19. Guided Occupational Training. A Vocational Work Experience Program for Intellectually Limited and Educationally Handicapped Students. Final Report.

    ERIC Educational Resources Information Center

    New York State Education Dept., Albany. Bureau of Occupational Education Research.

    Twenty-four intellectually limited and educationally handicapped 10th grade students participated in the first year of the Guided Occupational Training program of the Oceanside Senior High School. An academic core of English, citizenship, and mathematics was blended with classes in one of the following areas: (1) business education and office…

  20. Personal Development Resource Guide. A Resource for Teaching the Personal Development Core Course Area of Ohio's Work and Family Life Program.

    ERIC Educational Resources Information Center

    Kister, Joanna; And Others

    This Personal Development Resource Guide is intended to help teachers implement Ohio's Work and Family Life Program. Course content focuses on the practical problems faced by adolescents at the critical stage of their development. These practical problems are posed through case studies and shared experiences and examined using critical questions…

  1. Resource Management Resource Guide. A Resource for Teaching the Resource Management Core Course Area of Ohio's Work and Family Life Program.

    ERIC Educational Resources Information Center

    Kister, Joanna; And Others

    This Resource Management Resource Guide is intended to help teachers implement Ohio's Work and Family Life Program. Course content focuses on the practical problems related to managing human and material resources, making consumer decisions, and feeding, clothing, and housing the family. These practical problems are posed through case studies and…

  2. Agricultural Education Curriculum Guide. Agricultural Production and Management I. Course No. 6811. Agricultural Production and Management II. Course No. 6812.

    ERIC Educational Resources Information Center

    North Carolina State Dept. of Public Instruction, Raleigh.

    This document is designed for use by teachers of Agricultural Production and Management courses in North Carolina. It updates the competencies and content outlines from the previous guide. It lists core and optional competencies for two courses in seven areas as follows: leadership; supervised agricultural experience programs; animal science;…

  3. Positive Behavior Support in Secondary Schools: A Practical Guide. Practical Intervention in the Schools Series

    ERIC Educational Resources Information Center

    Young, Ellie L.; Caldarella, Paul; Richardson, Michael J.; Young, K. Richard

    2011-01-01

    This much-needed guide shows how to implement positive behavior support (PBS) strategies in secondary settings, using a three-tiered approach. The authors adapt the core ideas of PBS to the developmental context of adolescence and the organizational structures of middle schools and junior and senior high schools. With an emphasis on data-based…

  4. Mach-Zehnder atom interferometer inside an optical fiber

    NASA Astrophysics Data System (ADS)

    Xin, Mingjie; Leong, Wuiseng; Chen, Zilong; Lan, Shau-Yu

    2017-04-01

    Precision measurement with light-pulse grating atom interferometry in free space have been used in the study of fundamental physics and applications in inertial sensing. Recent development of photonic band-gap fibers allows light for traveling in hollow region while preserving its fundamental Gaussian mode. The fibers could provide a very promising platform to transfer cold atoms. Optically guided matter waves inside a hollow-core photonic band-gap fiber can mitigate diffraction limit problem and has the potential to bring research in the field of atomic sensing and precision measurement to the next level of compactness and accuracy. Here, we will show our experimental progress towards an atom interferometer in optical fibers. We designed an atom trapping scheme inside a hollow-core photonic band-gap fiber to create an optical guided matter waves system, and studied the coherence properties of Rubidium atoms in this optical guided system. We also demonstrate a Mach-Zehnder atom interferometer in the optical waveguide. This interferometer is promising for precision measurements and designs of mobile atomic sensors.

  5. High precision laser processing of sensitive materials by Microjet

    NASA Astrophysics Data System (ADS)

    Sibailly, Ochelio D.; Wagner, Frank R.; Mayor, Laetitia; Richerzhagen, Bernold

    2003-11-01

    Material laser cutting is well known and widely used in industrial processes, including micro fabrication. An increasing number of applications require nevertheless a superior machining quality than can be achieved using this method. A possibility to increase the cut quality is to opt for the water-jet guided laser technology. In this technique the laser is conducted to the work piece by total internal reflection in a thin stable water-jet, comparable to the core of an optical fiber. The water jet guided laser technique was developed originally in order to reduce the heat damaged zone near the cut, but in fact many other advantages were observed due to the usage of a water-jet instead of an assist gas stream applied in conventional laser cutting. In brief, the advantages are three-fold: the absence of divergence due to light guiding, the efficient melt expulsion, and optimum work piece cooling. In this presentation we will give an overview on several industrial applications of the water-jet guided laser technique. These applications range from the cutting of CBN or ferrite cores to the dicing of thin wafers and the manufacturing of stencils, each illustrates the important impact of the water-jet usage.

  6. A comparison of petrophysical data inputs for establishing time-depth relationships: a guide for future drilling expeditions

    NASA Astrophysics Data System (ADS)

    Boaga, J.; Sauermilch, I.; Mateo, Z. R. P.

    2017-12-01

    Time-depth relationships (TDR) are crucial in correlating drillhole and core information to seismic reflection profiles, for accurate resource estimation, scientific interpretation and to guide drilling operations. Conventional seismic time-depth domain conversion utilizes downhole sonic logs (DSI), calibrated using available checkshot data, which are local travel times from the surface to a particular depth. Scientific drilling programs (ODP and IODP) also measure P-wave velocity (PWL or C) on recovered core samples. Only three percent of all ODP and IODP sites record all three velocity measurements, however this information can be instructive as sometimes these data input show dissimilar TDR. These representative sites provide us with an opportunity to perform a comparative analysis highlighting the differences and similarities of TDRs derived from checkshot, downhole, and laboratory measurements. We then discuss the impact of lithology, stratigraphy, water column and other petrophysical properties in the predictive accuracy of TDR calculations, in an effort to provide guidance for future drilling and coring expeditions.

  7. Pre-Service Teachers' Perspectives on How the Use of TOON Comic Books during Guided Reading Influenced Learning by Struggling Readers

    ERIC Educational Resources Information Center

    McGrail, Ewa; Rieger, Alicja; Doepker, Gina M.; McGeorge, Samantha

    2018-01-01

    National guidelines such as the "Standards for the 21st Century Learner" (American Association of School Librarians, 2007) and the "Common Core State Standards" (Common Core State Standards, 2010) recognize the importance of using a wide range of informational texts, including comic books and graphic novels to teach content, in…

  8. 45 CFR 162.1203 - Operating rules for eligibility for a health plan transaction.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... plan transaction: (1) Phase I CORE 152: Eligibility and Benefit Real Time Companion Guide Rule, version... § 162.920). (5) Phase I CORE 156: Eligibility and Benefits Real Time Response Rule, version 1.1.0, March... 45 Public Welfare 1 2011-10-01 2011-10-01 false Operating rules for eligibility for a health plan...

  9. 45 CFR 162.1203 - Operating rules for eligibility for a health plan transaction.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... plan transaction: (1) Phase I CORE 152: Eligibility and Benefit Real Time Companion Guide Rule, version... § 162.920). (5) Phase I CORE 156: Eligibility and Benefits Real Time Response Rule, version 1.1.0, March... 45 Public Welfare 1 2013-10-01 2013-10-01 false Operating rules for eligibility for a health plan...

  10. 45 CFR 162.1203 - Operating rules for eligibility for a health plan transaction.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... plan transaction: (1) Phase I CORE 152: Eligibility and Benefit Real Time Companion Guide Rule, version... § 162.920). (5) Phase I CORE 156: Eligibility and Benefits Real Time Response Rule, version 1.1.0, March... 45 Public Welfare 1 2014-10-01 2014-10-01 false Operating rules for eligibility for a health plan...

  11. 45 CFR 162.1203 - Operating rules for eligibility for a health plan transaction.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... plan transaction: (1) Phase I CORE 152: Eligibility and Benefit Real Time Companion Guide Rule, version... § 162.920). (5) Phase I CORE 156: Eligibility and Benefits Real Time Response Rule, version 1.1.0, March... 45 Public Welfare 1 2012-10-01 2012-10-01 false Operating rules for eligibility for a health plan...

  12. MELT Bibliography. Materials Correlated with the Core Curriculum Competencies of the Mainstream English Language Training Project, Office of Refugee Resettlement.

    ERIC Educational Resources Information Center

    Brod, Shirley, Comp.; Sample, Barbara J.

    This bibliography is intended to assist teachers and administrators involved in competency-based, English as a second language (ESL) instruction. The materials included in the bibliography have been correlated with the core curriculum competencies of the Mainstream English Language Training (MELT) Project. The guide is divided into three parts.…

  13. Agricultural Business and Management Materials for Agricultural Education Programs. Core Agricultural Education Curriculum, Central Cluster.

    ERIC Educational Resources Information Center

    Illinois Univ., Urbana. Office of Agricultural Communications and Education.

    This curriculum guide contains 5 teaching units for 44 agricultural business and management cluster problem areas. These problem areas have been selected as suggested areas of study to be included in a core curriculum for secondary students enrolled in an agricultural education program. The five units are as follows: (1) agribusiness operation and…

  14. Faculty Perceptions of Core Components Perceived to Be Effective in Their Prominent Graduate Entrepreneurship Education Programs

    ERIC Educational Resources Information Center

    Taylor, James Grant

    2017-01-01

    The purpose of this study was to identify Core components perceived by faculty to be effective in their prominent graduate entrepreneurship education programs. The study sought to identify the best practices in graduate entrepreneurship education programs from the perceptions of faculty in the field. Research questions guiding the study were: (1)…

  15. You Seize What Pops Up: A Qualitative Investigation of the Core Features of School-Based Agricultural Education Professional Development

    ERIC Educational Resources Information Center

    Easterly, R.G., III.; Myers, Brian E.

    2017-01-01

    Desimone's core features of professional development (PD) guides the PD for teachers. The purpose of this study was to examine the PD practice of School-Based Agricultural Education (SBAE) teachers in the enthusiastic and growing career stage. Semi-structured telephone interviews were conducted with five teachers from five different states. The…

  16. Teachers' Perceptions of Increased Informational Reading Implemented within the Common Core

    ERIC Educational Resources Information Center

    Parkerson, Waverley

    2017-01-01

    The educational shift to the common core requires educators to increase the amount of informational text that is used within their classroom. The struggle for whole group use of informational text related to units of study proved to be challenging for teachers at the study site. Guided by constructivist theory that states learners must have the…

  17. Forum Guide to Supporting Data Access for Researchers: A Local Education Agency Perspective. NFES 2014-801

    ERIC Educational Resources Information Center

    National Forum on Education Statistics, 2014

    2014-01-01

    This document recommends a set of core practices, operations, and templates that can be adopted and adapted by local education agencies (LEAs) as they consider how to respond to requests for both new and existing data about the education enterprise. These recommendations reflect core best practices for: (1) managing the flow of requests; (2)…

  18. Development of the Learning Health System Researcher Core Competencies.

    PubMed

    Forrest, Christopher B; Chesley, Francis D; Tregear, Michelle L; Mistry, Kamila B

    2017-08-04

    To develop core competencies for learning health system (LHS) researchers to guide the development of training programs. Data were obtained from literature review, expert interviews, a modified Delphi process, and consensus development meetings. The competencies were developed from August to December 2016 using qualitative methods. The literature review formed the basis for the initial draft of a competency domain framework. Key informant semi-structured interviews, a modified Delphi survey, and three expert panel (n = 19 members) consensus development meetings produced the final set of competencies. The iterative development process yielded seven competency domains: (1) systems science; (2) research questions and standards of scientific evidence; (3) research methods; (4) informatics; (5) ethics of research and implementation in health systems; (6) improvement and implementation science; and (7) engagement, leadership, and research management. A total of 33 core competencies were prioritized across these seven domains. The real-world milieu of LHS research, the embeddedness of the researcher within the health system, and engagement of stakeholders are distinguishing characteristics of this emerging field. The LHS researcher core competencies can be used to guide the development of learning objectives, evaluation methods, and curricula for training programs. © Health Research and Educational Trust.

  19. A novel Zeonex based oligoporous-core photonic crystal fiber for polarization preserving terahertz applications

    NASA Astrophysics Data System (ADS)

    Islam, Md. Saiful; Sultana, Jakeya; Dinovitser, Alex; Ng, Brian W.-H.; Abbott, Derek

    2018-04-01

    A novel waveguide consisting of oligo-porous core photonic crystal fiber (PCF) with a kagome lattice cladding has been designed for highly birefringent and near zero dispersion flattened applications of terahertz waves. The wave guiding properties of the designed PCF including birefringence, dispersion, effective material loss (EML), core power fraction, confinement loss, and modal effective area are investigated using a full vector Finite Element Method (FEM) with Perfectly Matched Layer (PML) absorbing boundary condition. Simulation results demonstrate that an ultra-high birefringence of 0.079, low EML of 0.05 cm-1, higher core power fraction of 44% and negligible confinement loss of 7 . 24 × 10-7 cm-1 can be achieved at 1 THz. Furthermore, for the y-polarization mode a near zero flattened dispersion of 0 . 49 ± 0 . 05 ps/THz/cm is achieved within a broad frequency range of 0.8-1.7 THz. The fabrication of the proposed fiber is feasible using the existing fabrication technology. Due to favorable wave-guiding properties, the proposed fiber has potential for terahertz imaging, sensing and polarization maintaining applications in the terahertz frequency range.

  20. Guiding and amplification properties of rod-type photonic crystal fibers with sectioned core doping

    NASA Astrophysics Data System (ADS)

    Selleri, S.; Poli, F.; Passaro, D.; Cucinotta, A.; Lægsgaard, J.; Broeng, J.

    2009-05-01

    Rod-type photonic crystal fibers are large mode area double-cladding fibers with an outer diameter of few millimeters which can provide important advantages for high-power lasers and amplifiers. Numerical studies have recently demonstrated the guidance of higher-order modes in these fibers, which can worsen the output beam quality of lasers and amplifiers. In the present analysis a sectioned core doping has been proposed for Ybdoped rod-type photonic crystal fibers, with the aim to improve the higher-order mode suppression. A full-vector modal solver based on the finite element method has been applied to properly design the low refractive index ring in the fiber core, which can provide an increase of the differential overlap between the fundamental and the higher-order mode. Then, the gain competition among the guided modes along the Yb-doped rod-type fibers has been investigated with a spatial and spectral amplifier model. Simulation results have shown the effectiveness of the sectioned core doping in worsening the higher-order mode overlap on the doped area, thus providing an effective single-mode behavior of the Yb-doped rod-type photonic crystal fibers.

Top