DOE Office of Scientific and Technical Information (OSTI.GOV)
Vuchot, L.; Ginocchio, A. et al.
1959-10-31
As uranium ores, like most other ores, are not definite substances which can be treated directly for the production of the metal, the ores must be concentrated. The common physical processes used for all ores, such as sieving, gravimetric separation, flotation, electromagnetic separation, and electrostatic separation, are applicable to the beneficiation of uranium. The radioactivity of uranium ores has led to a radiometric method for the concentration. This method is described in detail. As an example, the preconcentration of Forez ores is discussed. (J.S.R.)
Zounr, Rizwan Ali; Tuzen, Mustafa; Deligonul, Nihal; Khuhawar, Muhammad Yar
2018-07-01
A simple, fast, green, sensitive and selective ultrasonic assisted deep eutectic solvent liquid-phase microextraction technique was used for preconcentration and extraction of cadmium (Cd) in water and food samples by electrothermal atomic absorption spectrometry (ETAAS). In this technique, a synthesized reagent (Z)-N-(3,5-diphenyl-1H-pyrrol-2-yl)-3,5-diphenyl-2H-pyrrol-2-imine (Azo) was used as a complexing agent for Cd. The main factors effecting the pre-concentration and extraction of Cd such as effect of pH, type and composition of deep eutectic solvent (DES), volume of DES, volume of complexing agent, volume of tetrahydrofuran (THF) and ultrasonication time have been examined in detail. At optimum conditions the value of pH and molar ratio of DES were found to be 6.0 and 1:4 (ChCl:Ph), respectively. The detection limit (LOD), limit of quantification (LOQ), relative standard deviation (RSD) and preconcentration factor (PF) were observed as 0.023 ng L -1 , 0.161 ng L -1 , 3.1% and 100, correspondingly. Validation of the developed technique was observed by extraction of Cd in certified reference materials (CRMs) and observed results were successfully compared with certified values. The developed procedure was practiced to various food, beverage and water samples. Copyright © 2018 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Manfroid, J.
2008-09-01
Fragmentation et astéroïdes binaires; Astéroïde géocroiseur triple; Rosetta sort de son hibernation; Messenger; Transit lunaire vu par Deep Impact; Titan; Phobos; Phoenix; Einstein avait raison; Le ballet des taches rouges; Le poids des lentilles;
Linker, Kevin L.; Conrad, Frank J.; Custer, Chad A.; Rhykerd, Jr., Charles L.
1998-01-01
An apparatus and method for preconcentrating particles and vapors. The preconcentrator apparatus permits detection of highly diluted amounts of particles in a main gas stream, such as a stream of ambient air. A main gas stream having airborne particles entrained therein is passed through a pervious screen. The particles accumulate upon the screen, as the screen acts as a sort of selective particle filter. The flow of the main gas stream is then interrupted by diaphragm shutter valves, whereupon a cross-flow of carrier gas stream is blown parallel past the faces of the screen to dislodge the accumulated particles and carry them to a particle or vapor detector, such as an ion mobility spectrometer. The screen may be heated, such as by passing an electrical current there through, to promote desorption of particles therefrom during the flow of the carrier gas. Various types of screens are disclosed. The apparatus and method of the invention may find particular utility in the fields of narcotics, explosives detection and chemical agents.
Linker, Kevin L.; Conrad, Frank J.; Custer, Chad A.; Rhykerd, Jr., Charles L.
2005-09-20
An apparatus and method for preconcentrating particles and vapors. The preconcentrator apparatus permits detection of highly diluted amounts of particles in a main gas stream, such as a stream of ambient air. A main gas stream having airborne particles entrained therein is passed through a pervious screen. The particles accumulate upon the screen, as the screen acts as a sort of selective particle filter. The flow of the main gas stream is then interrupted by diaphragm shutter valves, whereupon a cross-flow of carrier gas stream is blown parallel past the faces of the screen to dislodge the accumulated particles and carry them to a particle or vapor detector, such as an ion mobility spectrometer. The screen may be heated, such as by passing an electrical current there through, to promote desorption of particles therefrom during the flow of the carrier gas. Various types of screens are disclosed. The apparatus and method of the invention may find particular utility in the fields of narcotics, explosives detection and chemical agents.
Linker, Kevin L.; Conrad, Frank J.; Custer, Chad A.; Rhykerd, Jr., Charles L.
2000-01-01
An apparatus and method for preconcentrating particles and vapors. The preconcentrator apparatus permits detection of highly diluted amounts of particles in a main gas stream, such as a stream of ambient air. A main gas stream having airborne particles entrained therein is passed through a pervious screen. The particles accumulate upon the screen, as the screen acts as a sort of selective particle filter. The flow of the main gas stream is then interrupted by diaphragm shutter valves, whereupon a cross-flow of carrier gas stream is blown parallel past the faces of the screen to dislodge the accumulated particles and carry them to a particle or vapor detector, such as an ion mobility spectrometer. The screen may be heated, such as by passing an electrical current there through, to promote desorption of particles therefrom during the flow of the carrier gas. Various types of screens are disclosed. The apparatus and method of the invention may find particular utility in the fields of narcotics, explosives detection and chemical agents.
Linker, K.L.; Conrad, F.J.; Custer, C.A.; Rhykerd, C.L. Jr.
1998-12-29
An apparatus and method are disclosed for preconcentrating particles and vapors. The preconcentrator apparatus permits detection of highly diluted amounts of particles in a main gas stream, such as a stream of ambient air. A main gas stream having airborne particles entrained therein is passed through a pervious screen. The particles accumulate upon the screen, as the screen acts as a sort of selective particle filter. The flow of the main gas stream is then interrupted by diaphragm shutter valves, whereupon a cross-flow of carrier gas stream is blown parallel past the faces of the screen to dislodge the accumulated particles and carry them to a particle or vapor detector, such as an ion mobility spectrometer. The screen may be heated, such as by passing an electrical current there through, to promote desorption of particles therefrom during the flow of the carrier gas. Various types of screens are disclosed. The apparatus and method of the invention may find particular utility in the fields of narcotics, explosives detection and chemical agents. 3 figs.
Wang, Xiaoqin; Li, Guizhen; Ho Row, Kyung
2017-09-01
Deep eutectic solvents (DES) were formed from choline chloride (ChCl). DES-modified polymer monolithic (DES-M), template molecular polymer monolithic and non-DES-M without a molecular template were synthesized in identical process. These polymer materials were characterized by field emission scanning electron microscopy and Fourier transform infrared spectroscopy. The significant selective adsorption properties of the polymers were assessed by an absorption capacity experiment and solid-phase extraction (SPE). The optimized extraction procedure was as follows: ultrasonic time (30 min), optimal solvent (ethanol) and liquid to material ratio (20 mL g-1). Under this condition, the amount of quercetin extracted from Ginkgo biloba was 290.8 mg g-1. The purification of G. biloba was achieved by the SPE process. Based on the results, DESs-based monolithic cartridges can be used for simple and efficient extraction and as a pre-concentration technique for the purification of bioactive compounds or drugs in aqueous environments with high affinity and selectivity. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Factors Influencing Manual Performance in Cold Water Diving
2008-04-01
montrent que « l’engourdissement » n’avait pas d’incidence sur la dextérité à une profondeur de 40 m (p > 0,05). Dans l’eau à 25 ºC, les gants en ...sensibilité tactile et la dextérité proprement dite. Le rendement ( en anglais performance ou p) a été évalué à des profondeurs de 0,4 m et de 40 m, avec...communication et d’affichage fait en sorte que l’aptitude des plongeurs à utiliser des systèmes de commande complexes constitue un facteur important de la
NASA Astrophysics Data System (ADS)
Leger, Michel T.
Les activites humaines energivores telles l'utilisation intensive de l'automobile, la surconsommation de biens et l'usage excessif d'electricite contribuent aux changements climatiques et autres problemes environnementaux. Bien que plusieurs recherches rapportent que l'etre humain est de plus en plus conscient de ses impacts sur le climat de la planete, ces memes recherches indiquent qu'en general, les gens continuent a se comporter de facon non ecologique. Que ce soit a l'ecole ou dans la communaute, plusieurs chercheurs en education relative a l'environnement estiment qu'une personne bien intentionnee est capable d'adopter des comportements plus respectueux de l'environnement. Le but de cette these etait de comprendre le processus d'integration de comportements d'attenuation des changements climatiques dans des familles. A cette fin, nous nous sommes fixe deux objectifs : 1) decrire les competences et les procedes qui favorisent l'adoption de comportements d'attenuation des changements climatiques dans des familles et 2) decrire les facteurs et les dynamiques familiales qui facilitent et limitent l'adoption de comportements d'attenuation des changements climatiques dans des familles. Des familles ont ete invitees a essayer des comportements personnels et collectifs d'attenuation des changements climatiques de sorte a integrer des modes de vie plus ecologiques. Sur une periode de huit mois, nous avons suivi leur experience de changement afin de mieux comprendre comment se produit le processus de changement dans des familles qui decident volontairement d'adopter des comportements d'attenuation des changements climatiques. Apres leur avoir fourni quelques connaissances de base sur les changements climatiques, nous avons observe le vecu de changement des familles durant huit mois d'essais a l'aide de journaux reflexifs, d'entretiens d'explicitation et du journal du chercheur. La these comporte trois articles scientifiques. Dans le premier article, nous presentons une recension des ecrits sur le changement de comportement en environnement. Nous explorons egalement la famille comme systeme fonctionnel de sorte a mieux comprendre ce contexte d'action environnementale qui est, a notre connaissance, peu etudie. Dans le deuxieme article, nous presentons nos resultats de recherche concernant les facteurs d'influence observes ainsi que les competences manifestees au cours du processus d'adoption de nouveaux comportements environnementaux dans trois familles. Enfin, le troisieme article presente les resultats du cas d'une quatrieme famille ou les membres vivent depuis longtemps des modes de vie ecologique. Dans le cadre d'une demarche d'analyse par theorisation ancree, l'etude de ce cas modele nous a permis d'approfondir les categories conceptuelles identifiees dans le deuxieme article de sorte a produire une modelisation de l'integration de comportements environnementaux dans le contexte de la famille. Les conclusions degagees grace a la recension des ecrits nous ont permis d'identifier les elements qui pourraient influencer l'adoption de comportements environnementaux dans des familles. La recension a aussi permis une meilleure comprehension des divers facteurs qui peuvent affecter l'adoption de comportements environnementaux et, enfin, elle a permis de mieux cerner le phenomene de changement de comportement dans le contexte de la famille consideree comme un systeme. En appliquant un processus d'analyse inductif, a partir de nos donnees qualitatives, les resultats de notre etude multi-cas nous ont indique que deux construits conceptuels semblent influencer l'adoption de comportements environnementaux en famille : 1) les valeurs biospheriques communes au sein de la famille et 2) les competences collectivement mises a profit collectivement durant l'essai de nouveaux comportements environnementaux. Notre modelisation du processus de changement dans des familles indique aussi qu'une dynamique familiale collaborative et la presence d'un groupe de soutien exterieur sont deux elements conceptuels qui tendent a influencer les deux principaux construits et, par ce fait, tendent a augmenter les chances d'integrer de nouveaux comportements environnementaux dans des familles. En conclusion, nous presentons les limites de notre recherche ainsi que des pistes pour des recherches futures. Notamment, nous recommandons que l'ecole accueille les familles des eleves dans le cadre d'activites d'education a l'environnement ou les freres, les soeurs et les parents des eleves puissent apprendre ensemble, a l'ecole. Par exemple, nous recommandons la conduite en ERE d'une recherche action portant sur l'apprentissage intergenerationnel de nouveaux comportements dans le contexte de la famille. Mots-cles : education relative a l'environnement, comportement environnemental en famille, changement de comportement en famille, valeurs biospheriques, competences d'action.
2006-12-01
gestion de la masse d’informations nécessaires pour appuyer la prise de décision efficace. De l’avis des opérateurs d’engins télépilotés...opérateurs d’engins télépilotés risque de croître exponentiellement, de sorte que de fortes contraintes seront imposées au personnel exécutant les missions...commande réelle des engins télépilotés que la gestion des données, y compris la conversion de ces données en information et l’acheminement
Separate collection of plastic waste, better than technical sorting from municipal solid waste?
Feil, Alexander; Pretz, Thomas; Jansen, Michael; Thoden van Velzen, Eggo U
2017-02-01
The politically preferred solution to fulfil legal recycling demands is often implementing separate collection systems. However, experience shows their limitations, particularly in urban centres with a high population density. In response to the European Union landfill directive, mechanical biological waste treatment plants have been installed all over Europe. This technology makes it possible to retrieve plastic waste from municipal solid waste. Operators of mechanical biological waste treatment plants, both in Germany and the Netherlands, have started to change their mechanical separation processes to additionally produce plastic pre-concentrates. Results from mechanical biological waste treatment and separate collection of post-consumer packaging waste will be presented and compared. They prove that both the yield and the quality of plastic waste provided as feedstock for the production of secondary plastic raw material are largely comparable. An economic assessment shows which conditions for a technical sorting plant are economically attractive in comparison to separate collection systems. It is, however, unlikely that plastic recycling will ever reach cost neutrality.
Folding-paper-based preconcentrator for low dispersion of preconcentration plug
NASA Astrophysics Data System (ADS)
Lee, Kyungjae; Yoo, Yong Kyoung; Han, Sung Il; Lee, Junwoo; Lee, Dohwan; Kim, Cheonjung; Lee, Jeong Hoon
2017-12-01
Ion concentration polarization (ICP) has been widely studied for collecting target analytes as it is a powerful preconcentrator method employed for charged molecules. Although the method is quite robust, simple, cheap, and yields a high preconcentration factor, a major hurdle to be addressed is extracting the preconcentrated samples without dispersing the plug. This study investigates a 3D folding-paper-based ICP preconcentrator for preconcentrated plug extraction without the dispersion effect. The ICP preconcentrator is printed on a cellulose paper with pre-patterned hydrophobic wax. To extract and isolate the preconcentration plug with minimal dispersion, a 3D pop-up structure is fabricated via water drain, and a preconcentration factor of 300-fold for 10 min is achieved. By optimizing factors such as the electric field, water drain, and sample volume, the technique was enhanced by facilitating sample preconcentration and isolation, thereby providing the possibility for extensive applications in analytical devices such as lateral flow assays and FTAR cards.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guillet, H.
1959-02-01
A description is given of direct fluorination of preconcentrated uranium ores in order to obtain the hexafluoride. After normal sulfuric acid treatment of the ore to eliminate silica, the uranium is precipitated by lime to obtain either impure calcium uranate of medium grade, or containing around 10% of uranium. This concentrate is dried in an inert atmosphere and then treated with a current of elementary fluorine. The uranium hexafluoride formed is condensed at the outlet of the reaction vessel and may be used either for reduction to tetrafluoride and the subsequent manufacture of uranium metal or as the initial productmore » in a diffusion plant. (auth)« less
Identification des objets et detection de leur alignement en utilisant la technologie RFID
NASA Astrophysics Data System (ADS)
Rahma, Zayoud
De nos jours, les vehicules motorises sont essentiels dans notre vie quotidienne, d'ou la necessite de leur approvisionnement en carburant. L'approvisionnement en carburant peut entrainer certains inconvenients, tels que: les files d'attente, la disponibilite non-continuelle du carburant et les fraudes. Les problemes d'attente et de disponibilite non-continuelle du carburant peuvent etre facilement resolus en allant a une autre station d'essence aux alentours si disponibles. Par contre le probleme de fraudes est plus difficile a resoudre. De ce fait, decoule notre solution qui consiste a developper un systeme intelligent pour la gestion d'approvisionnement en carburant afin de remedier a ce probleme de fraudes. Pour des raisons de surete, il faut eviter les risques d'etincelles dans l'environnement du carburant. En particulier, il convient de ne pas utiliser un systeme utilisant 1'electricite proche de la pompe, du tuyau ou du reservoir du carburant du vehicule. Nous avons choisi la technologie RFID (Radio Frequency IDentification) et avons opte pour l'utilisation des etiquettes passives, etant donne que les etiquettes semi-passives ou actives contiennent une batterie electrique et sont nettement plus cheres. Un vehicule motorise sera identifie avec une etiquette RFID passive collee au-dessus du goulot de son reservoir. Deux autres etiquettes RFID seront placees sur le pistolet de sorte que le flux du carburant ne sera autorise que lorsque les trois etiquettes sont alignees. Notre travail etait a la demande d'une entreprise petroliere ayant une chaine internationale de stations de carburant. Le travail consiste en la conception, par la recherche, du systeme requis et s'articule sur l'optimisation de la topologie des antennes et des etiquettes de sorte que le systeme juge qu'il y a alignement lorsque le bec du pistolet est fonce dans le goulot du reservoir, et par consequent autorise le versement du carburant. Dans tous les autres cas, le systeme doit juger qu'il n'y a pas alignement et par consequent le flux du carburant n'est pas autorise. Mots cles: RFID, identification, localisation, alignement, fraudes, station-service.
ERIC Educational Resources Information Center
Kimmel, Allan J.
Public reactions to the Acquired Immune Deficiency Syndrome (AIDS) crisis are accompanied by the sorts of emotional and cognitive factors that have been identified by researchers as predictors of rumor generation and transmission. The present investigation attempted to ascertain the extent that various subjective factors (including anxiety,…
Microfluidic paper-based biomolecule preconcentrator based on ion concentration polarization.
Han, Sung Il; Hwang, Kyo Seon; Kwak, Rhokyun; Lee, Jeong Hoon
2016-06-21
Microfluidic paper-based analytical devices (μPADs) for molecular detection have great potential in the field of point-of-care diagnostics. Currently, a critical problem being faced by μPADs is improving their detection sensitivity. Various preconcentration processes have been developed, but they still have complicated structures and fabrication processes to integrate into μPADs. To address this issue, we have developed a novel paper-based preconcentrator utilizing ion concentration polarization (ICP) with minimal addition on lateral-flow paper. The cation selective membrane (i.e., Nafion) is patterned on adhesive tape, and this tape is then attached to paper-based channels. When an electric field is applied across the Nafion, ICP is initiated to preconcentrate the biomolecules in the paper channel. Departing from previous paper-based preconcentrators, we maintain steady lateral fluid flow with the separated Nafion layer; as a result, fluorescent dyes and proteins (FITC-albumin and bovine serum albumin) are continuously delivered to the preconcentration zone, achieving high preconcentration performance up to 1000-fold. In addition, we demonstrate that the Nafion-patterned tape can be integrated with various geometries (multiplexed preconcentrator) and platforms (string and polymer microfluidic channel). This work would facilitate integration of various ICP devices, including preconcentrators, pH/concentration modulators, and micro mixers, with steady lateral flows in paper-based platforms.
A MEMS Based Hybrid Preconcentrator/Chemiresistor Chemical Sensor
DOE Office of Scientific and Technical Information (OSTI.GOV)
HUGHES,ROBERT C.; PATEL,SANJAY V.; MANGINELL,RONALD P.
2000-06-12
A hybrid of a microfabricated planar preconcentrator and a four element chemiresistor array chip has been fabricated and the performance as a chemical sensor system has been demonstrated. The close proximity of the chemiresistor sensor to the preconcentrator absorbent layer allows for fast transfer of the preconcentrated molecules during the heating and resorption step. The hybrid can be used in a conventional flow sampling system for detection of low concentrations of analyte molecules or in a pumpless/valveless mode with a grooved lid to confine the desorption plume from the preconcentrator during heating.
Yu, Conrad M.; Koo, Jackson C.
2000-01-01
A system and method for preconcentrating, identifying, and quantifying chemical and biological substances is disclosed. An input valve directs a first volume of a sample gas to a surface acoustic wave (SAW) device. The SAW device preconcentrates and detects a mass of a substance within the sample gas. An output valve receives a second volume of the sample gas containing the preconcentrated substance from the SAW device and directs the second volume to a gas chromatograph (GC). The GC identifies the preconcentrated substance within the sample gas. A shunt valve exhausts a volume of the sample gas equal to the first volume minus the second volume away from the SAW device and the GC. The method of the present invention includes the steps of opening an input valve for passing a first volume of a sample gas to a SAW device; preconcentrating and detecting a mass of a substance within the sample gas using the SAW device; opening an output valve for passing a second volume of the sample gas containing the preconcentrated substance to a gas chromatograph (GC); and then identifying the preconcentrated substance within the sample gas using the GC.
Modular manifold for integrated fluidics and electronics
Adkins, Douglas Ray
2010-03-30
An airtight preconcentrator housing and/or a sensor housing for chemical testing, the housing(s) comprising internal dimensions such that a pre-manufactured preconcentrator and/or sensor can be disposed therein. The housings can also comprise electrical contacts disposed therein which align with and thus provide electrical connection to the preconcentrator and/or sensor. The preconcentrator and/or sensor can be easily and quickly replaced.
2014-11-24
aptamers to enhance specificity. Additionally, pre-concentration was coupled to various detection paradigms to achieve high-sensitivity biomarker... Aptamers , Biomarkers, Nanofluidics, Pre-concentration Devices, Sensing 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT SAR 18. NUMBER...devices and optimized electrokinetic pre-concentration conditions for key neurological biomarkers of interest, by using nanoparticles and aptamers to
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chapon, Emilien
Le paysage de la physique des particules a subi des changements majeurs entre le début de cette thèse, en septembre 2010, et sa n en juin 2013. On peut notamment qualier l'année 2012 de date-clé dans l'histoire de la physique des particules. En 2012, une nouvelle particule a été découverte au LHC [1, 2], dont la majeure partie de la communauté s'accorde aujourd'hui à dire qu'il s'agit très probablement du boson de Higgs. Cet événement est intervenu peu après une sorte de passage de relais entre le Tevatron, arrêté le 30 septembre 2011, et le LHC, dont les toutes premièresmore » collisions sont intervenues le 23 novembre 2009.« less
NASA Astrophysics Data System (ADS)
Chaiamornnugool, Phrompak; Tontapha, Sarawut; Phatchana, Ratchanee; Ratchapolthavisin, Nattawat; Kanokmedhakul, Somdej; Sang-aroon, Wichien; Amornkitbamrung, Vittaya
2017-01-01
The low cost DSSCs utilized by crude and pre-concentrated anthocyanins extracted from six anthocyanin-rich samples including mangosteen pericarp, roselle, red cabbage, Thai berry, black rice and blue pea were fabricated. Their photo-to-current conversion efficiencies and stability were examined. Pre-concentrated extracts were obtained by solid phase extraction (SPE) using C18 cartridge. The results obviously showed that all pre-concentrated extracts performed on photovoltaic performances in DSSCs better than crude extracts except for mangosteen pericarp. The DSSC sensitized by pre-concentrated anthocyanin from roselle and red cabbage showed maximum current efficiency η = 0.71% while DSSC sensitized by crude anthocyanin from mangosteen pericarp reached maximum efficiency η = 0.97%. In addition, pre-concentrated extract based cells possess more stability than those of crude extract based cells. This indicates that pre-concentration of anthocyanin via SPE method is very effective for DSSCs based on good photovoltaic performance and stability. The DFT/TDDFT calculations of electronic and photoelectrochemical properties of the major anthocyanins found in the samples are employed to support the experimental results.
Fallen fontanelle: culture-bound or cross-cultural?
Kay, M A
1993-04-01
Rather than bound to one culture, fallen fontanelle has been labeled as an illness or recognized as a symptom through time and space. The condition may be called siriasus, sitibundum, fontanellae collapsus, el apostema cálido del cerebro, Blatfallen, Blattschiessen, entzündung des Gehirns und der Gehirnhäute der Kleinen Kinder, coup de soleil, sorte de maladie causée par l'inflammation des membranes du cerveau, head-mould-shot, mollera caída, desmollerado, gual, split skull, sutt, nhova, kubabula, chipande, phogwana and dehydration. Defining features of this condition as well as prevention and treatment have corresponded to the specific cultural setting and ethnographic present. Fallen fontanelle (or fontanel) is "a culturally interpreted symptom rather than culture-bound" (Low 1985). The methodological perspective is an ethnohistorical recounting of change in the meaning of this symptom.
Tortuous path chemical preconcentrator
Manginell, Ronald P.; Lewis, Patrick R.; Adkins, Douglas R.; Wheeler, David R.; Simonson, Robert J.
2010-09-21
A non-planar, tortuous path chemical preconcentrator has a high internal surface area having a heatable sorptive coating that can be used to selectively collect and concentrate one or more chemical species of interest from a fluid stream that can be rapidly released as a concentrated plug into an analytical or microanalytical chain for separation and detection. The non-planar chemical preconcentrator comprises a sorptive support structure having a tortuous flow path. The tortuosity provides repeated twists, turns, and bends to the flow, thereby increasing the interfacial contact between sample fluid stream and the sorptive material. The tortuous path also provides more opportunities for desorption and readsorption of volatile species. Further, the thermal efficiency of the tortuous path chemical preconcentrator is comparable or superior to the prior non-planar chemical preconcentrator. Finally, the tortuosity can be varied in different directions to optimize flow rates during the adsorption and desorption phases of operation of the preconcentrator.
Cizek, Karel; Prior, Chad; Thammakhet, Chongdee; Galik, Michal; Linker, Kevin; Tsui, Ray; Cagan, Avi; Wake, John; La Belle, Jeff; Wang, Joseph
2010-02-19
This article reports on an integrated explosive-preconcentration/electrochemical detection system for 2,4,6-trinitrotoluene (TNT) vapor. The challenges involved in such system integration are discussed. A hydrogel-coated screen-printed electrode is used for the detection of the thermally desorbed TNT from a preconcentration device using rapid square wave voltammetry. Optimization of the preconcentration system for desorption of TNT and subsequent electrochemical detection was conducted yielding a desorption temperature of 120 degrees C under a flow rate of 500 mL min(-1). Such conditions resulted in a characteristic electrochemical signal for TNT representing the multi-step reduction process. Quantitative measurements produced a linear signal dependence on TNT quantity exposed to the preconcentrator from 0.25 to 10 microg. Finally, the integrated device was successfully demonstrated using a sample of solid TNT located upstream of the preconcentrator. Copyright 2009 Elsevier B.V. All rights reserved.
Liu, Vincent; Song, Yong-Ak; Han, Jongyoon
2010-06-07
In this paper, we report a novel method for fabricating ion-selective membranes in poly(dimethylsiloxane) (PDMS)/glass-based microfluidic preconcentrators. Based on the concept of capillary valves, this fabrication method involves filling a lithographically patterned junction between two microchannels with an ion-selective material such as Nafion resin; subsequent curing results in a high aspect-ratio membrane for use in electrokinetic sample preconcentration. To demonstrate the concentration performance of this high-aspect-ratio, ion-selective membrane, we integrated the preconcentrator with a surface-based immunoassay for R-Phycoerythrin (RPE). Using a 1x PBS buffer system, the preconcentrator-enhanced immunoassay showed an approximately 100x improvement in sensitivity within 30 min. This is the first time that an electrokinetic microfluidic preconcentrator based on ion concentration polarization (ICP) has been used in high ionic strength buffer solutions to enhance the sensitivity of a surface-based immunoassay.
Electrolytic preconcentration in instrumental analysis.
Sioda, R E; Batley, G E; Lund, W; Wang, J; Leach, S C
1986-05-01
The use of electrolytic deposition as a separation and preconcentration step in trace metal analysis is reviewed. Both the principles and applications of the technique are dealt with in some detail. Electrolytic preconcentration can be combined with a variety of instrumental techniques. Special attention is given to stripping voltammetry, potentiometric stripping analysis, different combinations with atomic-absorption spectrometry, and the use of flow-through porous electrodes. It is pointed out that the electrolytic preconcentration technique deserves more extensive use as well as fundamental investigation.
High throughput liquid absorption preconcentrator sampling instrument
Zaromb, Solomon; Bozen, Ralph M.
1992-01-01
A system for detecting trace concentrations of an analyte in air includes a preconcentrator for the analyte and an analyte detector. The preconcentrator includes an elongated tubular container comprising a wettable material. The wettable material is continuously wetted with an analyte-sorbing liquid which flows from one part of the container to a lower end. Sampled air flows through the container in contact with the wetted material with a swirling motion which results in efficient transfer of analyte vapors or aerosol particles to the sorbing liquid and preconcentration of traces of analyte in the liquid. The preconcentrated traces of analyte may be either detected within the container or removed therefrom for injection into a separate detection means or for subsequent analysis.
High-throughput liquid-absorption preconcentrator sampling methods
Zaromb, Solomon
1994-01-01
A system for detecting trace concentrations of an analyte in air includes a preconcentrator for the analyte and an analyte detector. The preconcentrator includes an elongated tubular container comprising a wettable material. The wettable material is continuously wetted with an analyte-sorbing liquid which flows from one part of the container to a lower end. Sampled air flows through the container in contact with the wetted material with a swirling motion which results in efficient transfer of analyte vapors or aerosol particles to the sorbing liquid and preconcentration of traces of analyte in the liquid. The preconcentrated traces of analyte may be either detected within the container or removed therefrom for injection into a separate detection means or for subsequent analysis.
High throughput liquid absorption preconcentrator sampling instrument
Zaromb, S.; Bozen, R.M.
1992-12-22
A system for detecting trace concentrations of an analyte in air includes a preconcentrator for the analyte and an analyte detector. The preconcentrator includes an elongated tubular container comprising a wettable material. The wettable material is continuously wetted with an analyte-sorbing liquid which flows from one part of the container to a lower end. Sampled air flows through the container in contact with the wetted material with a swirling motion which results in efficient transfer of analyte vapors or aerosol particles to the sorbing liquid and preconcentration of traces of analyte in the liquid. The preconcentrated traces of analyte may be either detected within the container or removed therefrom for injection into a separate detection means or for subsequent analysis. 12 figs.
High-throughput liquid-absorption preconcentrator sampling methods
Zaromb, S.
1994-07-12
A system for detecting trace concentrations of an analyte in air includes a preconcentrator for the analyte and an analyte detector. The preconcentrator includes an elongated tubular container comprising a wettable material. The wettable material is continuously wetted with an analyte-sorbing liquid which flows from one part of the container to a lower end. Sampled air flows through the container in contact with the wetted material with a swirling motion which results in efficient transfer of analyte vapors or aerosol particles to the sorbing liquid and preconcentration of traces of analyte in the liquid. The preconcentrated traces of analyte may be either detected within the container or removed therefrom for injection into a separate detection means or for subsequent analysis. 12 figs.
Design and Analysis of a Preconcentrator for the ChemLab
DOE Office of Scientific and Technical Information (OSTI.GOV)
WONG,CHUNGNIN C.; FLEMMING,JEB H.; MANGINELL,RONALD P.
2000-07-17
Preconcentration is a critical analytical procedure when designing a microsystem for trace chemical detection, because it can purify a sample mixture and boost the small analyte concentration to a much higher level allowing a better analysis. This paper describes the development of a micro-fabricated planar preconcentrator for the {mu}ChemLab{trademark} at Sandia. To guide the design, an analytical model to predict the analyte transport, adsorption and resorption process in the preconcentrator has been developed. Experiments have also been conducted to analyze the adsorption and resorption process and to validate the model. This combined effort of modeling, simulation, and testing has ledmore » us to build a reliable, efficient preconcentrator with good performance.« less
Non-planar chemical preconcentrator
Manginell, Ronald P [Albuquerque, NM; Adkins, Douglas R [Albuquerque, NM; Sokolowski, Sara S [Albuquerque, NM; Lewis, Patrick R [Albuquerque, NM
2006-10-10
A non-planar chemical preconcentrator comprises a high-surface area, low mass, three-dimensional, flow-through sorption support structure that can be coated or packed with a sorptive material. The sorptive material can collect and concentrate a chemical analyte from a fluid stream and rapidly release it as a very narrow temporal plug for improved separations in a microanalytical system. The non-planar chemical preconcentrator retains most of the thermal and fabrication benefits of a planar preconcentrator, but has improved ruggedness and uptake, while reducing sorptive coating concerns and extending the range of collectible analytes.
Odor Sensing System Using Preconcentrator with Variable Temperature
DOE Office of Scientific and Technical Information (OSTI.GOV)
Isaka, Y; Nakamoto, Takamichi; Moriizumi, T
1999-01-01
An odor sensing system using QCM gas sensor array and pattern recognition technique is useful to identify various kinds of odors. A preconcentrator with variable temperature is promising to obtain further pattern separation after the appropriate temperature changes, whereas it has been so far used to enhance sensor sensitivity. After the preconcentrator collects the vapors, it is heated so that they can be thermally desorbed. The combination of the preconcentrator with the sensor array enhances the capability of discrimination among vapors since their desorption temperatures depend upon vapor kinds.
Chemical preconcentrator with integral thermal flow sensor
Manginell, Ronald P.; Frye-Mason, Gregory C.
2003-01-01
A chemical preconcentrator with integral thermal flow sensor can be used to accurately measure fluid flow rate in a microanalytical system. The thermal flow sensor can be operated in either constant temperature or constant power mode and variants thereof. The chemical preconcentrator with integral thermal flow sensor can be fabricated with the same MEMS technology as the rest of the microanlaytical system. Because of its low heat capacity, low-loss, and small size, the chemical preconcentrator with integral thermal flow sensor is fast and efficient enough to be used in battery-powered, portable microanalytical systems.
Karacan, Mehmet Sayim; Aslantaş, Neslihan
2008-07-15
In this study, Fe, Cr and Ni have been preconcentrated and removed by using N,N'-ethylenebis (ethane sulfonamide), (ESEN) ligand on activated carbon (AC) in aqueous solution. For this purpose, complexes between these metals and ligands have been investigated and used in preconcentration and removal studies. Factors which have affected adsorption of metals on activated carbon have been optimized. Adsorbed metals have been preconcentrated 10-fold and determined by ICP-OES. Interferences of Ca, Mg and K to this process have been investigated. The proposed method has been applied to the tap water and Ankara Creek water in order to Fe, Cr, and Ni remediation and preconcentration. Determination of metals by ICP-OES has been checked with standard reference material (NIST 1643e). The proposed method provides the recoveries of 87%, 108% and 106% for Fe, Cr and Ni, respectively, in preconcentration. It also provides the removal of Fe, Cr and Ni by 93%, 100% and 100% removal from waters, respectively.
1981-09-01
doessais do torborsotour MAKILA nous avons choisi trois easais gui ont pour objet die asiuier qoolguos ones des conditions oxposees prece6demisont et gui...46laLore one lin dv d~bit. Los ossais ao banc consistent A 6rablir cette loi poor 6n fonictionnement aui eol do sorte I cqutiie couvrei lensemble du...laisserons de c6t6 le facteur de ddcroissanco du prix en fonction du rang de s6rie ( loi de Wright) parce que, do par sa g6ndralit6, il n’est pas influenc6
Method and apparatus for concentrating vapors for analysis
Grate, Jay W [West Richland, WA; Baldwin, David L [Kennewick, WA; Anheier, Jr., Norman C.
2012-06-05
A pre-concentration device and a method are disclosed for concentrating gaseous vapors for analysis. Vapors sorbed and concentrated within the bed of the pre-concentration device are thermally desorbed, achieving at least partial separation of the vapor mixtures. The pre-concentration device is suitable, e.g., for pre-concentration and sample injection, and provides greater resolution of peaks for vapors within vapor mixtures, yielding detection levels that are 10-10,000 times better than direct sampling and analysis systems. Features are particularly useful for continuous unattended monitoring applications. The invention finds application in conjunction with, e.g., analytical instruments where low detection limits for gaseous vapors are desirable.
Azarova, Yu A; Pestov, A V; Ustinov, A Yu; Bratskaya, S Yu
2015-12-10
Chitosan and its N-heterocyclic derivatives N-2-(2-pyridyl)ethylchitosan (2-PEC), N-2-(4-pyridyl) ethylchitosan (4-PEC), and N-(5-methyl-4-imidazolyl) methylchitosan (IMC) have been applied in group preconcentration of gold, platinum, and palladium for subsequent determination by atomic absorption spectroscopy (AAS) in solutions with high background concentrations of iron and sodium ions. It has been shown that the sorption mechanism, which was elucidated by XPS, significantly influences the sorption capacity of materials, the efficiency of metal ions elution after preconcentration, and, as a result, the accuracy of metal determination by AAS. We have shown that native chitosan was not suitable for preconcentration of Au(III), if the elution step was used as a part of the analysis scheme. The group preconcentration of Au(III), Pd(II), and Pt(IV) with subsequent quantitative elution using 0.1M HCl/1M thiourea solution was possible only on IMC and 4-PEC. Application of IMC for analysis of the national standard quartz ore sample proved that gold could be accurately determined after preconcentration/elution with the recovery above 80%. Copyright © 2015 Elsevier Ltd. All rights reserved.
Marchisio, P F; Sales, A; Cerutti, S; Marchevski, E; Martinez, L D
2005-09-30
The present paper proposes an on-line preconcentration procedure for lead determination in Ilex paraguariensis (St. Hilaire) samples by ultrasonic nebulization associated to inductively coupled plasma optical emission spectrometry (USN-ICP-OES). It is based on the precipitation of lead(II) ion on a minicolumn packed with polyurethane foam using 2-(5-bromo-2-pyridilazo)-5-diethylaminophenol (5-Br-PADAP) as precipitating reagent. The collected analyte precipitate was quantitatively eluted from the minicolumn with 20% (v/v) nitric acid. An enhancement factor of 225-fold was obtained (15 for USN and 15 for preconcentration). The detection limit (DL) value for the preconcentration of 10.0 ml of sample was 40.0 ng/l. The relative standard deviation (R.S.D.) was 3.0% for a Pb concentration of 1 microg/l, calculated from the peak heights obtained. The calibration graph using the preconcentration system for lead was linear with a correlation coefficient of 0.9997, at levels near the detection limits up to at least 100 microg/l. The preconcentration procedure was successfully applied to the determination of lead in mate tea samples.
NASA Astrophysics Data System (ADS)
Lebel, Larry
Une procedure experimentale a ete developpee pour caracteriser les mecanismes de deterioration et la durabilite de materiaux composites a matrice ceramique (CMC) dans une application de piece statique de turbine a gaz. Tandis que la plupart des essais de caracterisation publies sur les materiaux CMC ont ete realises sous des conditions de chargement controle, la presente recherche tente de reproduire la relaxation des contraintes qui se produit normalement dans une piece statique a haute temperature. Dans l'experience proposee, un echantillon planaire de forme haltere est chauffe de facon cyclique sur une de ses faces et refroidi sur l'autre, tout en etant contraint dans ses deplacements. La contrainte de flexion resultante au centre de l'echantillon, mesuree par une cellule de charge, correspond a la contrainte de flexion qui a ete prealablement predite au centre des panneaux d'une chambre a combustion generique. Un materiau CMC multicouche compose d'une matrice d'alumine poreuse et de fibres NextelMD 720 a ete utilise pour developper l'experience. Des essais de calibration ont d'abord ete realises en utilisant un systeme de chauffage par lampe infrarouge, atteignant jusqu'a 1160 °C a la surface de l'echantillon. Un systeme laser au CO2 a par la suite ete utilise pour realiser des essais de deterioration a haute puissance, atteignant en fin d'essai des temperatures de surface excedant la limite de 1200 °C du materiau et des differences de temperature a travers l'epaisseur de plus de 1000 °C. Sous la puissance de chauffage imposee a amplitude constante, l'accumulation de dommage a fait en sorte d'augmenter la temperature en surface et les gradients de temperature a travers le materiau. Une reduction de la contrainte dans le temps a ete observee a cause du fluage, de la fissuration et de la delamination du materiau sous la condition de confinement du deplacement, menant a une stabilisation du niveau de dommage a une certaine profondeur dependant de la contrainte thermique initiale. La procedure de caracterisation developpee s'avere etre un outil prometteur pour developper de nouveaux types de materiaux, de meme que pour comparer la durabilite de materiaux existants sous des conditions representatives de pieces statiques de turbine a gaz. None
Method for preconcentrating a sample for subsequent analysis
Zaromb, Solomon
1990-01-01
A system for analysis of trace concentration of contaminants in air includes a portable liquid chromatograph and a preconcentrator for the contaminants to be analyzed. The preconcentrator includes a sample bag having an inlet valve and an outlet valve for collecting an air sample. When the sample is collected the sample bag is connected in series with a sorbing apparatus in a recirculation loop. The sorbing apparatus has an inner gas-permeable container containing a sorbent material and an outer gas-impermeable container. The sample is circulated through the outer container and around the inner container for trapping and preconcentrating the contaminants in the sorbent material. The sorbent material may be a liquid having the same composition as the mobile phase of the chromatograph for direct injection thereinto. Alternatively, the sorbent material may be a porous, solid body, to which mobile phase liquid is added after preconcentration of the contaminants for dissolving the contaminants, the liquid solution then being withdrawn for injection into the chromatograph.
Yoo, Yong Kyoung; Yoon, Dae Sung; Kim, Gangeun; Kim, Jinsik; Han, Sung Il; Lee, Junwoo; Chae, Myung-Sic; Lee, Sang-Myung; Lee, Kyu Hyoung; Hwang, Kyo Seon; Lee, Jeong Hoon
2017-10-30
Sensitivity and limit of detection (LOD) enhancement are essential criteria for the development of ultrasensitive molecular sensors. Although various sensor types have been investigated to enhance sensitivity and LOD, analyte detection and its quantification are still challenging, particularly for protein-protein interactions with low association constants. To solve this problem, here, we used ion concentration polarization (ICP)-based preconcentration to increase the local concentration of analytes in a microfluidic platform for LOD improvement. This was the first demonstration of a microfluidic device with an integrated ICP preconcentrator and interdigitated microelectrode (IME) sensor to detect small changes in surface binding between antigens and antibodies. We detected the amyloid beta (Aβ) protein, an Alzheimer's disease marker, with low binding affinity to its antibodies by adopting ICP preconcentration phenomena. We demonstrated that a combination of ICP preconcentrator and IME sensor increased the LOD by 13.8-fold to femtomolar level (8.15 fM), which corresponds to a significant advance for clinical applications.
Ansari, Ashley J; Hai, Faisal I; Guo, Wenshan; Ngo, Hao H; Price, William E; Nghiem, Long D
2016-10-01
This study demonstrated a technique using forward osmosis (FO) to pre-concentrate the organic matter in raw wastewater, thereby transforming low strength wastewater into an anaerobically digestible solution. The chemical oxygen demand (COD) of raw wastewater was concentrated up to approximately eightfold at a water recovery of 90%. Thus, even low strength wastewater could be pre-concentrated by FO to the range suitable for biogas production via anaerobic treatment. Excessive salinity accumulation in pre-concentrated wastewater was successfully mitigated by adopting ionic organic draw solutes, namely, sodium acetate, and EDTA-2Na. These two draw solutes are also expected to benefit the digestibility of the pre-concentrated wastewater compared to the commonly used draw solute sodium chloride. Significant membrane fouling was observed when operating at 90% water recovery using raw wastewater. Nevertheless, membrane fouling was reversible and was effectively controlled by optimising the hydrodynamic conditions of the cross-flow FO system. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.
Real-time dual-loop electric current measurement for label-free nanofluidic preconcentration chip.
Chung, Pei-Shan; Fan, Yu-Jui; Sheen, Horn-Jiunn; Tian, Wei-Cheng
2015-01-07
An electrokinetic trapping (EKT)-based nanofluidic preconcentration device with the capability of label-free monitoring trapped biomolecules through real-time dual-loop electric current measurement was demonstrated. Universal current-voltage (I-V) curves of EKT-based preconcentration devices, consisting of two microchannels connected by ion-selective channels, are presented for functional validation and optimal operation; universal onset current curves indicating the appearance of the EKT mechanism serve as a confirmation of the concentrating action. The EKT mechanism and the dissimilarity in the current curves related to the volume flow rate (Q), diffusion coefficient (D), and diffusion layer (DL) thickness were explained by a control volume model with a five-stage preconcentration process. Different behaviors of the trapped molecular plug were categorized based on four modes associated with different degrees of electroosmotic instability (EOI). A label-free approach to preconcentrating (bio)molecules and monitoring the multibehavior molecular plug was demonstrated through real-time electric current monitoring, rather than through the use of microscope images.
Jerez, Javier; Isaguirre, Andrea C; Bazán, Cristian; Martinez, Luis D; Cerutti, Soledad
2014-06-01
An on-line scandium preconcentration and determination system implemented with inductively coupled plasma optical emission spectrometry associated with flow injection was studied. Trace amounts of scandium were preconcentrated by sorption on a minicolumn packed with oxidized multiwalled carbon nanotubes, at pH 1.5. The retained analyte was removed from the minicolumn with 30% (v/v) nitric acid. A total enrichment factor of 225-fold was obtained within a preconcentration time of 300 s (for a 25 mL sample volume). The overall time required for preconcentration and elution of 25 mL of sample was about 6 min; the throughput was about 10 samples per hour. The value of the detection limit was 4 ng L(-1) and the precision for 10 replicate determinations at 100 ng L(-1) Sc level was 5% relative standard deviation, calculated from the peak heights obtained. The calibration graph using the preconcentration system was linear with a correlation coefficient of 0.9996 at levels near the detection limits up to at least 10 mg L(-1). After optimization, the method was successfully applied to the determination of Sc in an acid drainage from an abandoned mine located in the province of San Luis, Argentina. Copyright © 2014 Elsevier B.V. All rights reserved.
Submarine landslides: advances and challenges
Locat, Jacques; Lee, Homa J.
2002-01-01
Due to the recent development of well-integrated surveying techniques of the sea floor, significant improvements were achieved in mapping and describing the morphology and architecture of submarine mass movements. Except for the occurrence of turbidity currents, the aquatic environment (marine and fresh water) experiences the same type of mass failure as that found on land. Submarine mass movements, however, can have run-out distances in excess of 100 km, so their impact on any offshore activity needs to be integrated over a wide area. This great mobility of submarinemass movements is still not very well understood, particularly for cases like the far-reaching debris flows mapped on the Mississippi Fan and the large submarine rock avalanches found around many volcanic islands. A major challenge ahead is the integration of mass movement mechanics in an appropriate evaluation of the hazard so that proper risk assessment methodologies can be developed and implemented for various human activities offshore, including the development of natural resources and the establishment of reliable communication corridors. Key words : submarine slides, hazards, risk assessment, morphology, mobility, tsunami. Le dveloppement rcent de techniques de levs hydrograhiques pour les fonds marins nous a permis d'atteindre une qualit ingale dans la cartographie et la description des glissements sous marins. l'exception des courants de turbidit, on retrouve dans le domaine aquatique les mmes types de mouvements de terrain que sur terre. Par contre, les glissements sous-marins peuvent atteindre des distances excdant 100 km de telle sorte que leur impact sur les activits offshore doit tre pris en compte sur degrandes tendues. La grande mobilit des glissements sous-marins n'est pas encore bien comprise, comme pour le cas des coules dedbris cartographies sur le cne du Mississippi ainsi que pour les grandes avalanches rocheuses sous-marines retrouves au pourtour des les volcaniques. Un dfi majeur auquel nous faisons face est celui de dterminer les alas associs aux divers types demouvements sous-marins ainsi que les risques associs l'activit humaine, telle que l'exploitation des ressources naturelles et l'tablissement de routes de communications fiables. Mots cls : glissements sous-marins, morphologie, ala, risque, mobilit, tsunami.
de la Rosa, Carlos; Prakash, Ranjit; Tilley, Peter A; Fox, Julie D; Kaler, Karan V i S
2007-01-01
An integrated microfluidic system for combined manipulation, pre-concentration, and lysis of samples containing Bordetella pertussis by dielectrophoresis and electroporation has been developed and implemented. The microfluidic device was able to pre-concentrate the amount of B. pertussis cells present in 200 microl of a B. pertussis suspension stock into a 20 microl volume. The device exhibited optimal sample pre-concentration of 6.7x at a stock value of 10(3) cfu/ml and at a flow rate of 250 microl/h. Electro-disruption experiments showed that on-chip-based electroporation is an effective solution for lysis of B. pertussis cells that is easily integrated with dielectrophoresis assisted pre-concentration procedures. Pulsed voltage applied, number of pulses, and presence of potassium chloride in a B. pertussis suspension showed a reduction in B. pertussis cell viability by electroporation; and transmission electron microscopy confirmed B. pertussis cell disruption by electroporation. Genetic amplification and detection of the pre-concentrated sample employing an integrated chip-based system demonstrated a complete chip approach for pathogen detection.
Battery operated preconcentration-assisted lateral flow assay.
Kim, Cheonjung; Yoo, Yong Kyoung; Han, Sung Il; Lee, Junwoo; Lee, Dohwan; Lee, Kyungjae; Hwang, Kyo Seon; Lee, Kyu Hyoung; Chung, Seok; Lee, Jeong Hoon
2017-07-11
Paper-based analytical devices (e.g. lateral flow assays) are highly advantageous as portable diagnostic systems owing to their low costs and ease of use. Because of their low sensitivity and detection limits for biomolecules, these devices have several limitations in applications for real-field diagnosis. Here, we demonstrate a paper-based preconcentration enhanced lateral flow assay using a commercial β-hCG-based test. Utilizing a simple 9 V battery operation with a low power consumption of approximately 81 μW, we acquire a 25-fold preconcentration factor, demonstrating a clear sensitivity enhancement in the colorimetric lateral flow assay; consequently, clear colors are observed in a rapid kit test line, which cannot be monitored without preconcentration. This device can also facilitate a semi-quantitative platform using the saturation value and/or color intensity in both paper-based colorimetric assays and smartphone-based diagnostics.
Afzali, Darush; Mostafavi, Ali; Taher, Mohammad Ali; Rezaeipour, Ebrahim; Khayatzadeh Mahani, Mohammad
2005-04-01
A procedure for separation and preconcentration of trace amounts of cadmium has been proposed. A column of analcime zeolite modified with benzyldimethyltetradecylammonium chloride and loaded with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) was used for retention of cadmium. The cadmium was quantitatively retained on the column at pH approximately 9 and was recovered from column with 5 ml of 2 M nitric acid with a preconcentration factor of 140. Anodic stripping differential pulse voltammetry was used for determination of cadmium. A 0.05 ng/ml detection limit for the preconcentration of aqueous solution of cadmium was obtained. The relative standard deviation (RSD) for eight replicate determinations at the 1 microg/ml cadmium levels was 0.31% (calculated with the peak height obtained). The calibration graph using the preconcentration system was linear from 0.01 to 150 microg/ml in final solution with a correlation coefficient of 0.9997. For optimization of conditions, various parameters such as the effect of pH, flow rate, instrumental conditions and interference of number of ions, were studied in detail. This method was successfully applied for determination of cadmium in various complex samples.
Cajamarca, Fabio Antonio Suquila; Corazza, Marcela Zanetti; Prete, Maiyara Caroline; Dragunski, Douglas Cardoso; Rocker, Cristiana; Caetano, Josiane; Gonçalves Júnior, Affonso Celso; Tarley, César Ricardo Teixeira
2016-12-01
In this study, a new method for the preconcentration of cadmium ions using modified aquatic macrophytes - Salvinia molesta as biosorbent in an on-line preconcentration system coupled to flame atomic absorption spectrometry (FAAS) was developed. The method is based on preconcentration of 20.0 mL sample at pH 3.75 through 35.0 mg of biosorbent at 10.0 mL min -1 and subsequent elution with 0.5 mol L -1 HNO 3 . A preconcentration factor of 31-fold, linear dynamic range from 5.0 to 70.0 µg L -1 (r = 0.9996) and detection and quantification limits of 0.15 and 0.51 µg L -1 were obtained. The characterization of the biosorbent chemically modified with NaOH and citric acid, was performed through FTIR and SEM measurements. The method precision was found to be 3.97 % and 1.48 % for 5.0 and 60.0 µg L -1 Cd(II) solutions, respectively. The applicability of method was checked by analysis of different kind of water samples and certified reference material.
Some, Donmozoun Télesphore; Some, Der Adolphe; Hien, Hervé; Diallo, Ramata; Zingue, Dézémon; Diallo, Ibrahim; Diagbouga, Serge; Dao, Blami
2012-01-01
Introduction Les adolescentes sont très vulnérables face aux Infections Sexuellement Transmissibles (IST) et au VIH/SIDA. Notre étude a pour objectifs d’explorer la qualité de la communication entre les adolescentes et leurs parents sur les IST/VIH/SIDA et de recueillir leurs suggestions pour l’amélioration de cette communication. Méthodes L’étude était transversale qualitative sur 2 mois. La population de l’étude était composée par des adolescentes de 13 à 17 ans et leurs parents habitant la ville de Bobo Dioulasso. Vingt (20) adolescentes scolarisées ont été tirés au sort dans trois établissements secondaires et 20 autres non scolarisées choisies de façon accidentelle dans la ville. Les informations ont été collectées à l’aide de 8 focus groups. Les discussions ont été enregistrées sur cassettes, retranscrites en verbatim, et analysées à l’aide du logiciel QSR NVIVO 2.0. Résultats Les adolescentes et leurs parents communiquent très peu ou pas sur les questions des IST/VIH/SIDA; l’auto-information par les paires ou les médias est la première source d’information. Pour les parents, l’information existe et est accessible aux adolescentes alors que pour ces dernières, leurs connaissances de ces maladies sont parfois erronées. L’abstinence, la fidélité et le dépistage volontaire comme moyen de prévention sont très peu évoqués par les adolescentes de même que par leurs parents. Conclusion La communication parents-adolescentes est insuffisante voire absente dans certains milieux. Il est urgent de conduire des actions auprès des adolescentes et leurs parents pour mieux les informer sur les IST/VIH/SIDA et améliorer la communication sur ces maladies. PMID:22655099
Two-stage preconcentrator for vapor/particle detection
Linker, Kevin L.; Brusseau, Charles A.
2002-01-01
A device for concentrating particles from a high volume gas stream and delivering the particles for detection in a low volume gas stream includes first and second preconcentrators. The first preconcentrator has a first structure for retaining particles in a first gas flow path through which a first gas flows at a relatively high volume, valves for selectively stopping the first gas flow; and a second gas flow path through which gas flows at an intermediate flow volume for moving particles from the first structure. The second preconcentrator includes a second structure for retaining particles in the second gas flow path; a valve for selectively stopping the second gas flow; and a third gas flow path through which gas flows at a low volume for moving particles from the second structure to a detector. Each of the particle retaining structures is preferably a metal screen that may be resistively heated by application of an electric potential to release the particles.
NASA Astrophysics Data System (ADS)
Wysocka, Irena; Vassileva, Emilia
2017-02-01
Analytical procedure for the determination of fourteen rare earth elements (REEs) in the seawater samples has been developed and validated. The elements (La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu) at ultra-trace level were measured by high resolution sector field inductively coupled plasma mass spectrometry (HR ICP-SFMS) after off-line analytes pre-concentration and matrix separation. The sample pre-treatment was carried out by commercially available automated system seaFAST-pico™, which is a low-pressure ion chromatography technique, based on solid phase extraction principles. Efficient elimination of seawater matrix and up to 50-fold pre-concentration of REEs enabled their accurate and precise quantification at ng L- 1 level. A validation approach in line with the requirements of ISO/IEC 17025 standard and Eurachem guidelines were followed. With this in mind, selectivity, working range, linearity, recovery (from 92% to 102%), repeatability (1%-4%), intermediate precision (2%-6%), limits of detection (0.001-0.08 ng L- 1) were systematically assessed. The total uncertainty associated to each result was estimated and the main sources of uncertainty sorted out. All major contributions to the combined uncertainty of the obtained results were identified and propagated together, following the ISO/GUM guidelines. The relative expanded uncertainty was estimated at range from 10.4% to 11.6% (k = 2). Demonstration of traceability of measurement results was also presented. Due to the low limits of detection, this method enables the determination of ultra-low levels of REEs in the open seawater as well as small variations in their concentrations. The potential of the proposed analytical procedure, based on combination of seaFAST-pico™ for sample preparation and HR ICP-SFMS, was demonstrated by direct analysis of seawater form different regions of the world.
Review of the critical current densities and magnetic irreversibilities in high T_c superconductors
NASA Astrophysics Data System (ADS)
Senoussi, S.
1992-07-01
This review article is concerned with critical current density (J) and magnetic irreversibilities in high-T_c superconductors (HTSC). The apparent J derived from different experimental techniques (transport, hysteresis cycle, ac-susceptibility) are compared. The influence of time (relaxation effects) as well as the macroscopic size of the sample on the criteria defining J are discussed. The dependences of the critical current on grain boundaries (“weaks-links”), texturing and other physical and chemical defects are examined in detail. The role of self fields is clarified. The critical current is strongly influenced by the anisotropy of the layered structure practically whatever the experimental conditions. Intrinsic pinning is lowered by defects. Demagnetizing effects and surface pinnings are reviewed. The usual critical state and flux creep models are recalled emphasizing the physical aspects most specific to HTSC. A theoretical model which takes into account the equilibrium magnetization and sample granularity is developed. It reproduces most of the characteristic features of both the hysteresis cycle and ac-susceptibility. A number of new formulae are introduced. They generalize the Bean model and show how to correct for the dimensions of the grains (granular materials), the macroscopic radius of the sample, anisotropy and demagnetization effects in certain situations. Several limits beyond which the usual critical state breaks down are discussed: (1) the quasi elastic limit where the variable field is too weak to depin the vortices, (2) H≈ H_C1 so that the interaction between vortex lines is exponentially weak and (3) T and H close to the “irreversibility line” where the influence of viscous forces are strong. (4) Hgg H_C1 so that J is governed by collective pinning. Ce papier de revue est consacré aux courant critiques (J) et aux irréversibilités magnétiques dans les nouveaux matériaux supraconducteurs (HTSC). Nous y comparons les densités des courants critiques effectives déduites à partir des techniques expérimentales les plus courantes (transport, cycle d'hystérésis, susceptibilité alternative, ...). L'influence de l'échelle du temps de la mesure et de la taille effective de l'échantillon sur les divers critères définissant J est examinée en détail. La dépendance de ce courant en fonction des joints de grains (“liens faibles”), du degré de texture et des autres défauts physiques et chimiques est discutée. Le rôle du champ propre est clarifié. Le courant critique est très dépendant de l'anisotropie de l'échnatillon dans pratiquement toutes les conditions expérimentales. L'ancrage intrinsèque est détérioré par les défauts. Le rôle des effets démagnétisants et de la surface de l'échantillon sur les résultats expérimentaux est passé en revue. Les modèles de l'état critique et de “flus creep” sont rappelés en insistant sur les aspects les plus spécifiques des HTSC. Un modèle théorique est proposé. Il tient compte de l'aimantation réversible, des aspects granulaires et reproduit à la fois les propriétés les plus typiques des cycles d'hystérésis et de la suscceptibilité alternative. Plusieurs formules nouvelles généralisant le modèle de Bean en sont déduites. Elles montrent comment tenir compte des dimensions des grains (matériaux granulaires), du rayon macroscopique, de l'anisotropie et des effets démagnétisants, dans certaines conditions. Plusieurs limites au-delà desquelles les concepts classiques de l'état critique cessent d'être valides sont également examinés : (1) la limite élastique où le champ de mesure est trop faible pour dépiéger les vortex, (2) H≈ H_C1 de sorte que les interactions entre vortex sont exponentiellement faibles et (3) et T voisins de la ligne d'irréversibilité où les forces de viscosité jouent un rôle prépondérant. (4) Hgg H_C1 de sorte que J est imposé par l'ancrage collectif.
Li, Ping; Hynes, Sara R; Haefele, Thomas F; Pudipeddi, Madhu; Royce, Alan E; Serajuddin, Abu T M
2009-05-01
The solution of a poorly water-soluble drug in a liquid lipid-surfactant mixture, which served as a microemulsion preconcentrate, was converted into a solid form by incorporating it in a solid polyethylene glycol (PEG) matrix. The solid microemulsion preconcentrates thus formed consisted of Capmul PG8 (propylene glycol monocaprylate) as oil, Cremophor EL (polyoxyl 35 castor oil) as surfactant, and hydrophilic polymer PEG 3350 as solid matrix. The drug (aqueous solubility: 0.17 microg/mL at pH 1-8 and 25 degrees C) was dissolved in a melt of the mixture at 65-70 degrees C and then the hot solution was filled into hard gelatin capsules; the liquid gradually solidified upon cooling below 55 degrees C. The solid system was characterized by differential scanning calorimetry (DSC), scanning electron microscopy (SEM), confocal Raman microscopy (CRM), and the dispersion testing in water. It was confirmed that a solid microemulsion preconcentrate is a two-phase system, where clusters of crystalline PEG 3350 formed the solid structure (m.p. 55-60 degrees C) and the liquid microemulsion preconcentrate dispersed in between PEG 3350 crystals as a separate phase. The drug remained dissolved in the liquid phase. In vitro release testing showed that the preconcentrate dispersed readily in water forming a microemulsion with the drug dissolved in the oil particles (<150 nm) and the presence of PEG 3350 did not interfere with the process of self-microemulsification.
Karimi, Mehdi; Dadfarnia, Shayessteh; Shabani, Ali Mohammad Haji; Tamaddon, Fatemeh; Azadi, Davood
2015-11-01
Deep eutectic liquid organic salt was used as the solvent and a liquid phase microextraction (DES-LPME) combined with electrothermal atomic absorption spectrometry (ETAAS) was developed for separation, preconcentration and determination of lead and cadmium in edible oils. A 4:1 mixture of deep eutectic solvent and 2% nitric acid (200 µL) was added to an oil sample. The mixture was vortexed and transferred into a water bath at 50 °C and stirred for 5 minutes. After the extraction was completed, the phases were separated by centrifugation, and the enriched analytes in the deep eutectic solvent phase were determined by ETAAS. Under optimized extraction conditions and for an oil sample of 28 g, enhancement factors of 198 and 195 and limits of detection (defined as 3 Sb/m) of 8 and 0. 2 ng kg(-1) were achieved for lead and cadmium respectively. The method was successfully applied to the determination of lead and cadmium in various edible oils. Copyright © 2015. Published by Elsevier B.V.
Manginell, Ronald P [Albuquerque, NM; Bunker, Bruce C [Albuquerque, NM; Huber, Dale L [Albuquerque, NM
2008-09-09
A biological preconcentrator comprises a stimulus-responsive active film on a stimulus-producing microfabricated platform. The active film can comprise a thermally switchable polymer film that can be used to selectively absorb and desorb proteins from a protein mixture. The biological microfabricated platform can comprise a thin membrane suspended on a substrate with an integral resistive heater and/or thermoelectric cooler for thermal switching of the active polymer film disposed on the membrane. The active polymer film can comprise hydrogel-like polymers, such as poly(ethylene oxide) or poly(n-isopropylacrylamide), that are tethered to the membrane. The biological preconcentrator can be fabricated with semiconductor materials and technologies.
Sample extraction and injection with a microscale preconcentrator.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robinson, Alex Lockwood; Chan, Helena Kai Lun
2007-09-01
This report details the development of a microfabricated preconcentrator that functions as a fully integrated chemical extractor-injector for a microscale gas chromatograph (GC). The device enables parts-per-billion detection and quantitative analysis of volatile organic compounds (VOCs) in indoor air with size and power advantages over macro-scale systems. The 44 mm{sup 3} preconcentrator extracts VOCs using highly adsorptive, granular forms of graphitized carbon black and carbon molecular sieves. The micron-sized silicon cavities have integrated heating and temperature sensing allowing low power, yet rapid heating to thermally desorb the collected VOCs (GC injection). The keys to device construction are a new adsorbent-solventmore » filling technique and solvent-tolerant wafer-level silicon-gold eutectic bonding technology. The product is the first granular adsorbent preconcentrator integrated at the wafer level. Other advantages include exhaustive VOC extraction and injection peak widths an order of magnitude narrower than predecessor prototypes. A mass transfer model, the first for any microscale preconcentrator, is developed to describe both adsorption and desorption behaviors. The physically intuitive model uses implicit and explicit finite differences to numerically solve the required partial differential equations. The model is applied to the adsorption and desorption of decane at various concentrations to extract Langmuir adsorption isotherm parameters from effluent curve measurements where properties are unknown a priori.« less
Zinc oxide nanorods functionalized paper for protein preconcentration in biodiagnostics
NASA Astrophysics Data System (ADS)
Tiwari, Sadhana; Vinchurkar, Madhuri; Rao, V. Ramgopal; Garnier, Gil
2017-03-01
Distinguishing a specific biomarker from a biofluid sample containing a large variety of proteins often requires the selective preconcentration of that particular biomarker to a detectable level for analysis. Low-cost, paper-based device is an emerging opportunity in diagnostics. In the present study, we report a novel Zinc oxide nanorods functionalized paper platform for the preconcentration of Myoglobin, a cardiac biomarker. Zinc oxide nanorods were grown on a Whatman filter paper no. 1 via the standard hydrothermal route. The growth of Zinc oxide nanorods on paper was confirmed by a combination of techniques consisting of X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS,) scanning electron microscopy (SEM), and energy dispersive spectroscopy (EDX) analysis. The Zinc oxide nanorods modified Whatman filter paper (ZnO-NRs/WFP) was further tested for use as a protein preconcentrator. Paper-based ELISA was performed for determination of pre-concentration of cardiac marker protein Myoglobin using the new ZnO-NRs/WFP platform. The ZnO-NRs/WFP could efficiently capture the biomarker even from a very dilute solution (Myoglobin < 50 nM). Our ELISA results show a threefold enhancement in protein capture with ZnO-NRs/WFP compared to unmodified Whatman filter paper, allowing accurate protein analysis and showing the diagnostic concept.
Chiu, Ping-Hsien; Weng, Chen-Hsun; Yang, Ruey-Jen
2015-01-01
A fluidic microchip incorporating a convergent microchannel and a Nafion-nanoporous membrane is proposed for the preconcentration and separation of multi-species samples on a single platform. In the device, sample preconcentration is achieved by means of the ion concentration polarization effect induced at the micro/nano interface under the application of an external electric field, while species separation is achieved by exploiting the different electrophoretic mobilities of the sample components. The experimental results show that the device is capable of detecting C-reactive protein (CRP) with an initial concentration as low as 9.50 × 10−6 mg/L given a sufficient preconcentration time and driving voltage. In addition, it is shown that a mixed-species sample consisting of three negatively-charged components (bovine serum albumin (BSA), tetramethylrhodamine(TAMRA) isothiocyanate-Dextran and fluorescent polymer beads) can be separated and preconcentrated within 20 min given a driving voltage of 100 V across 1 cm microchannel in length. In general, the present results confirm the feasibility of the device for the immunoassay or detection of various multi-species samples under low concentration in the biochemical and biomedical fields. The novel device can therefore improve the detection limit of traditional medical facilities. PMID:26690167
Veenstra, Gerry
2015-05-01
The longstanding debate between the homology and omnivorism approaches to the class bases of cultural tastes and practices rages on in cultural sociology. The homology thesis claims that class positions throughout the class hierarchy are accompanied by specified cultural tastes and specialized modes of appreciating them while the cultural omnivorism thesis contends that elites are (increasingly) characterized by a breadth of cultural tastes of any and all kinds. This study tests the applicability of these theses to musical tastes in Canada through the application of multiple correspondence analysis, latent class analysis, and logistic regression modeling to original telephone survey data (n = 1,595) from Toronto and Vancouver. I find that musical omnivorism, an appreciation for diverse musical styles, is not dispersed along class lines. Instead I find a homology between class position and musical tastes that designates blues, choral, classical, jazz, musical theater, opera, pop, reggae, rock, and world/international as relatively highbrow and country, disco, easy listening, golden oldies, heavy metal, and rap as relatively lowbrow. Of the highbrow tastes, all but jazz are disliked by lower class people, and of the lowbrow tastes, country, easy listening, and golden oldies are concurrently disliked by higher class people. Consistent with the homology thesis, it appears that class position is aligned with specific musical likes and dislikes. Le vieux débat entre les approches de l'homologie et de l'omnivorisme aux bases des classes des goûts et des pratiques culturels fait rage dans la sociologie culturelle. La thèse de l'homologie prétend que les positions des classes à travers la hiérarchie des classes sont accompagnées par des goûts culturels spécifiés et des modes spécialisés permettant leur appréciation. La thèse de l'omnivorisme culturel, en revanche, soutient que les élites sont (de plus en plus) caractérisées par un éventail de goûts culturels de toutes sortes. Cette étude expérimente l'applicabilité de ces thèses aux goûts musicaux au Canada à travers l'application de l'analyse des correspondances multiples, de l'analyse des classes latentes et du modèle de régression logistique aux données d'origine de l'étude collectées par téléphone (n = 1,595) de Toronto et de Vancouver. Je me rends compte que l'omnivorisme musical, une appréciation de styles musicaux divers, n'est pas dispersé le long des classes sociales. Bien au contraire, je trouve qu'il existe une homologie entre la position des classes et les goûts musicaux qui désigne les blues, la chorale, la musique classique, le jazz, le théâtre musical, l'opéra, la pop, le reggae, le rock et la musique du monde/internationale comme des styles des classes au niveau intellectuel relativement élevé. Cette homologie désigne la country, la disco, la musique d'ambiance, les anciens succès, le heavy metal et le rap comme des styles des classes au niveau intellectuel relativement bas. Des goûts des classes au niveau intellectuel élevé, tous les styles à l'exception du jazz ne sont pas appréciés de la basse classe. De même, des goûts des classes au niveau intellectuel bas, le country, la musique d'ambiance et les anciens succès ne sont pas appréciés de la haute classe. Selon la thèse de l'homologie, il apparaît que la position des classes est fonction des préférences et des aversions musicales spécifiques. © 2015 Canadian Sociological Association/La Société canadienne de sociologie.
TEST AND EVALUATION OF A POLYMER MEMBRANE PRECONCENTRATOR
The report gives results of an evaluation of the applicability of membrane systems as a preconcentrator and defines operating parameters of a membrane system. Advantages of such a system is a potential reduction in cost for subsequent control systems. The evaluation is part of a ...
Analytical instrument with apparatus and method for sample concentrating
Zaromb, S.
1986-08-04
A system for analysis of trace concentrations of contaminants in air includes a portable liquid chromatograph and a preconcentrator for the contaminants to be analyzed. The preconcentrator includes a sample bag having an inlet valve and an outlet valve for collecting an air sample. When the sample is collected the sample bag is connected in series with a sorbing apparatus in a recirculation loop. The sorbing apparatus has an inner gas-permeable container containing a sorbent material and an outer gas-impermeable container. The sample is circulated through the outer container and around the inner container for trapping and preconcentrating the contaminants in the sorbent material. The sorbent material may be a liquid having the same composition as the mobile phase of the chromatograph for direct injection thereinto. Alternatively, the sorbent material may be a porous, solid body, to which mobile phase liquid is added after preconcentration of the contaminants for dissolving the contaminants, the liquid solution then being withdrawn for injection into the chromatograph.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jenkins, T.F.; Thorne, P.G.; Myers, K.F.
Salting-out solvent extraction (SOE) was compared with cartridge and membrane solid-phase extraction (SPE) for preconcentration of nitroaromatics, nitramines, and aminonitroaromatics prior to determination by reversed-phase high-performance liquid chromatography. The solid phases used were manufacturer-cleaned materials, Porapak RDX for the cartridge method and Empore SDB-RPS for the membrane method. Thirty-three groundwater samples from the Naval Surface Warfare Center, Crane, Indiana, were analyzed using the direct analysis protocol specified in SW846 Method 8330, and the results were compared with analyses conducted after preconcentration using SOE with acetonitrile, cartridge-based SPE, and membrane-based SPE. For high-concentration samples, analytical results from the three preconcentration techniquesmore » were compared with results from the direct analysis protocol; good recovery of all target analytes was achieved by all three pre-concentration methods. For low-concentration samples, results from the two SPE methods were correlated with results from the SOE method; very similar data was obtained by the SOE and SPE methods, even at concentrations well below 1 microgram/L.« less
Escudero, Luis A; Pacheco, Pablo H; Gasquez, José A; Salonia, José A
2015-02-15
A preconcentration system has been developed to determine inorganic selenium species. Selenium was retained by a column filled with polyvinyl chloride (PVC) with lanthanum hydroxide co-precipitation. Speciation was achieved by selective photoreduction previous Se preconcentration. The retention pH was optimized at 10.0. Two multivariate calibrations and a central composite design were employed for optimization of the system. Sample, reagents and acid flow rates are significant variables affecting the system. Employing HG-ICP-OES as detection, the optimized system reached a detection limit of 0.03μg/L, and an enhancement factor of 14875 (25 for preconcentration system, 595 for hydride generation). To verify the method' accuracy, two certified reference materials, BCR® 414 Plankton & IRMM-804 Rice Flour, were analysed. The system was applied to inorganic selenium speciation in several Argentinean beverages to estimate their selenium contribution to diet. Copyright © 2014 Elsevier Ltd. All rights reserved.
Application of polyurethane foam as a sorbent for trace metal pre-concentration — A review
NASA Astrophysics Data System (ADS)
Lemos, V. A.; Santos, M. S.; Santos, E. S.; Santos, M. J. S.; dos Santos, W. N. L.; Souza, A. S.; de Jesus, D. S.; das Virgens, C. F.; Carvalho, M. S.; Oleszczuk, N.; Vale, M. G. R.; Welz, B.; Ferreira, S. L. C.
2007-01-01
The first publication on the use of polyurethane foam (PUF) for sorption processes dates back to 1970, and soon after the material was applied for separation processes. The application of PUF as a sorbent for solid phase extraction of inorganic analytes for separation and pre-concentration purposes is reviewed. The physical and chemical characteristics of PUF (polyether and polyester type) are discussed and an introduction to the characterization of these sorption processes using different types of isotherms is given. Separation and pre-concentration methods using unloaded and loaded PUF in batch and on-line procedures with continuous flow and flow injection systems are presented. Methods for the direct solid sampling analysis of the PUF after pre-concentration are discussed as well as approaches for speciation analysis. Thermodynamic proprieties of some extraction processes are evaluated and the interpretation of determined parameters, such as enthalpy, entropy and Gibbs free energy in light of the physico-chemical processes is explained.
Analytical instrument with apparatus for sample concentrating
Zaromb, Solomon
1989-01-01
A system for analysis of trace concentrations of contaminants in air includes a portable liquid chromatograph and a preconcentrator for the contaminants to be analyzed. The preconcentrator includes a sample bag having an inlet valve and an outlet valve for collecting an air sample. When the sample is collected the sample bag is connected in series with a sorbing apparatus in a recirculation loop. The sorbing apparatus has an inner gas-permeable container containing a sorbent material and an outer gas-impermeable container. The sample is circulated through the outer container and around the inner container for trapping and preconcentrating the contaminants in the sorbent material. The sorbent material may be a liquid having the same composition as the mobile phase of the chromatograph for direct injection thereinto. Alternatively, the sorbent material may be a porous, solid body, to which mobile phase liquid is added after preconcentration of the contaminants for dissolving the contaminants, the liquid solution then being withdrawn for injection into the chromatograph.
Liquid-absorption preconcentrator sampling instrument
Zaromb, Solomon
1990-01-01
A system for detecting trace concentrations of an analyte in air and includes a preconcentrator for the analyte and an analyte detector. The preconcentrator includes an elongated tubular container in which is disposed a wettable material extending substantially the entire length of the container. One end of the wettable material is continuously wetted with an analyte-sorbing liquid, which flows to the other end of the container. Sample air is flowed through the container in contact with the wetted material for trapping and preconcentrating the traces of analyte in the sorbing liquid, which is then collected at the other end of the container and discharged to the detector. The wetted material may be a wick comprising a bundle of fibers, one end of which is immersed in a reservoir of the analyte-sorbing liquid, or may be a liner disposed on the inner surface of the container, with the sorbing liquid being centrifugally dispersed onto the liner at one end thereof. The container is preferably vertically oriented so that gravity effects the liquid flow.
Liquid-absorption preconcentrator sampling instrument
Zaromb, S.
1990-12-11
A system is described for detecting trace concentrations of an analyte in air and includes a preconcentrator for the analyte and an analyte detector. The preconcentrator includes an elongated tubular container in which is disposed a wettable material extending substantially the entire length of the container. One end of the wettable material is continuously wetted with an analyte-sorbing liquid, which flows to the other end of the container. Sample air is flowed through the container in contact with the wetted material for trapping and preconcentrating the traces of analyte in the sorbing liquid, which is then collected at the other end of the container and discharged to the detector. The wetted material may be a wick comprising a bundle of fibers, one end of which is immersed in a reservoir of the analyte-sorbing liquid, or may be a liner disposed on the inner surface of the container, with the sorbing liquid being centrifugally dispersed onto the liner at one end thereof. The container is preferably vertically oriented so that gravity effects the liquid flow. 4 figs.
Sharma, R K; Pandey, Amit; Gulati, Shikha; Adholeya, Alok
2012-03-30
A novel, highly selective, efficient and reusable chelating resin, diphenyldiketone-monothiosemicarbazone modified silica gel, was prepared and applied for the on-line separation and preconcentration of Pd(II) ions in catalytic converter and spiked tap water samples. Several parameters like effect of pH, sample volume, flow rate, type of eluent, and influence of various ionic interferences, etc. were evaluated for effective adsorption of palladium at trace levels. The resin was found to be highly selective for Pd(II) ions in the pH range 4-5 with a very high sorption capacity of 0.73 mmol/g and preconcentration factor of 335. The present environment friendly procedure has also been applied for large-scale extraction by employing the use of newly designed reactor in which on-line separation and preconcentration of Pd can be carried out easily and efficiently in short duration of time. Copyright © 2012 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cong, Yongzheng; Katipamula, Shanta; Geng, Tao
2016-02-01
A microfluidic platform was developed to perform online electrokinetic sample preconcentration and rapid hydrodynamic sample injection for electrophoresis using a single microvalve. The PDMS microchip consists of a separation channel, a side channel for sample introduction, and a control channel which is used as a pneumatic microvalve aligned at the intersection of the two flow channels. The closed microvalve, created by multilayer soft lithography, can serve as a preconcentrator under an applied electric potential, enabling current to pass through while blocking bulk flow. Once analytes are concentrated, the valve is briefly opened and the stacked sample is pressure injected intomore » the separation channel for electrophoretic separation. Fluorescently labeled peptides were enriched by a factor of ~450 in 230 s. The performance of the platform was validated by the online preconcentration, injection and electrophoretic separation of fluorescently labeled peptides. This method enables both rapid analyte concentration and controlled injection volume for high sensitivity, high resolution capillary electrophoresis.« less
NASA Astrophysics Data System (ADS)
Shirkhanloo, H.; Falahnejad, M.; Zavvar Mousavi, H.
2016-01-01
A rapid enrichment method based on solid-phase extraction (SPE) has been established for preconcentration and separation of trace Ni(II) ions in water samples prior to their determination by atom trap flame atomic absorption spectrometry. A column filled with bulky NH2-UVM7 was used as the novel adsorbent. Under optimal conditions, the linear range, limit of detection (LOD), and preconcentration factor (PF) were 3-92 μg/L, 0.8 μg/L, and 100, respectively. The validity of the method was checked by the standard reference material.
Chae, Myung-Sic; Kim, Jinsik; Yoo, Yong Kyoung; Kang, Ji Yoon; Lee, Jeong Hoon; Hwang, Kyo Seon
2015-01-01
Preventing unexpected explosive attacks and tracing explosion-related molecules require the development of highly sensitive gas-vapor detection systems. For that purpose, a micromechanical cantilever-based olfactory sensing system including a sample preconcentrator was developed to detect 2,4-dinitrotoluene (2,4-DNT), which is a well-known by-product of the explosive molecule trinitrotoluene (TNT) and exists in concentrations on the order of parts per billion in the atmosphere at room temperature. A peptide receptor (His-Pro-Asn-Phe-Ser-Lys-Tyr-Ile-Leu-His-Gln-Arg) that has high binding affinity for 2,4-DNT was immobilized on the surface of the cantilever sensors to detect 2,4-DNT vapor for highly selective detection. A micro-preconcentrator (µPC) was developed using Tenax-TA adsorbent to produce higher concentrations of 2,4-DNT molecules. The preconcentration was achieved via adsorption and thermal desorption phenomena occurring between target molecules and the adsorbent. The µPC directly integrated with a cantilever sensor and enhanced the sensitivity of the cantilever sensor as a pretreatment tool for the target vapor. The response was rapidly saturated within 5 min and sustained for more than 10 min when the concentrated vapor was introduced. By calculating preconcentration factor values, we verified that the cantilever sensor provides up to an eightfold improvement in sensing performance. PMID:26213944
The tissue micro-array data exchange specification: a web based experience browsing imported data
Nohle, David G; Hackman, Barbara A; Ayers, Leona W
2005-01-01
Background The AIDS and Cancer Specimen Resource (ACSR) is an HIV/AIDS tissue bank consortium sponsored by the National Cancer Institute (NCI) Division of Cancer Treatment and Diagnosis (DCTD). The ACSR offers to approved researchers HIV infected biologic samples and uninfected control tissues including tissue cores in micro-arrays (TMA) accompanied by de-identified clinical data. Researchers interested in the type and quality of TMA tissue cores and the associated clinical data need an efficient method for viewing available TMA materials. Because each of the tissue samples within a TMA has separate data including a core tissue digital image and clinical data, an organized, standard approach to producing, navigating and publishing such data is necessary. The Association for Pathology Informatics (API) extensible mark-up language (XML) TMA data exchange specification (TMA DES) proposed in April 2003 provides a common format for TMA data. Exporting TMA data into the proposed format offers an opportunity to implement the API TMA DES. Using our public BrowseTMA tool, we created a web site that organizes and cross references TMA lists, digital "virtual slide" images, TMA DES export data, linked legends and clinical details for researchers. Microsoft Excel® and Microsoft Word® are used to convert tabular clinical data and produce an XML file in the TMA DES format. The BrowseTMA tool contains Extensible Stylesheet Language Transformation (XSLT) scripts that convert XML data into Hyper-Text Mark-up Language (HTML) web pages with hyperlinks automatically added to allow rapid navigation. Results Block lists, virtual slide images, legends, clinical details and exports have been placed on the ACSR web site for 14 blocks with 1623 cores of 2.0, 1.0 and 0.6 mm sizes. Our virtual microscope can be used to view and annotate these TMA images. Researchers can readily navigate from TMA block lists to TMA legends and to clinical details for a selected tissue core. Exports for 11 blocks with 3812 cores from three other institutions were processed with the BrowseTMA tool. Fifty common data elements (CDE) from the TMA DES were used and 42 more created for site-specific data. Researchers can download TMA clinical data in the TMA DES format. Conclusion Virtual TMAs with clinical data can be viewed on the Internet by interested researchers using the BrowseTMA tool. We have organized our approach to producing, sorting, navigating and publishing TMA information to facilitate such review. We have converted Excel TMA data into TMA DES XML, and imported it and TMA DES XML from another institution into BrowseTMA to produce web pages that allow us to browse through the merged data. We proposed enhancements to the TMA DES as a result of this experience. We implemented improvements to the API TMA DES as a result of using exported data from several institutions. A document type definition was written for the API TMA DES (that optionally includes proposed enhancements). Independent validators can be used to check exports against the DTD (with or without the proposed enhancements). Linking tissue core images to readily navigable clinical data greatly improves the value of the TMA. PMID:16086837
Xu, Kai-Xuan; Guo, Mei-Hong; Huang, Yu-Ping; Li, Xiao-Dong; Sun, Jian-Jun
2018-04-01
A highly sensitive and rapid method of in-situ surface-enhanced Raman spectroscopy (SERS) combining with electrochemical preconcentration (EP) in detecting malachite green (MG) in aquaculture water was established. Ag nanoparticles (AgNPs) were synthesized and spread onto the surface of gold electrodes after centrifuging to produce SERS-active substrates. After optimizing the pH values, preconcentration potentials and times, in-situ EP-SERS detection was carried out. A sensitive and rapid analysis of the low-concentration MG was accomplished within 200s and the limit of detection was 2.4 × 10 -16 M. Copyright © 2017 Elsevier B.V. All rights reserved.
Apparatus for sensing volatile organic chemicals in fluids
Hughes, Robert C.; Manginell, Ronald P.; Jenkins, Mark W.; Kottenstette, Richard; Patel, Sanjay V.
2005-06-07
A chemical-sensing apparatus is formed from the combination of a chemical preconcentrator which sorbs and concentrates particular volatile organic chemicals (VOCs) and one or more chemiresistors that sense the VOCs after the preconcentrator has been triggered to release them in concentrated form. Use of the preconcentrator and chemiresistor(s) in combination allows the VOCs to be detected at lower concentration than would be possible using the chemiresistor(s) alone and further allows measurements to be made in a variety of fluids, including liquids (e.g. groundwater). Additionally, the apparatus provides a new mode of operation for sensing VOCs based on the measurement of decay time constants, and a method for background correction to improve measurement precision.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parmeter, J.E.; Custer, C.A.
This project was supported by LDRD funding for the development and preliminary testing of a portable narcotics detection system. The system developed combines a commercial trace detector known as an ion mobility spectrometer (IMS) with a preconcentrator originally designed by Department 5848 for the collection of explosives molecules. The detector and preconcentrator were combined along with all necessary accessories onto a push cart, thus yielding a fully portable detection unit. Preliminary testing with both explosives and narcotics molecules shown that the system is operational, and that it can successfully detect drugs as marijuana, methamphetamine (speed), and cocaine based on theirmore » characteristics IMS signatures.« less
NASA Astrophysics Data System (ADS)
Ferenc, Kovats
1986-07-01
Desuis mon enfance je suis un type soidisant visuel. Cette deviation etait toujours profitable pour moi, pour le clinicien , ainsi que pour le rechercheur scientifique.I1 y a trente ans, que dans l'Atlas Radioanatomique du Thorax nous avons deja utilis6 la conception de trois dimensions. Dans les derni6res edition de cet ouvrage nous avons travaille mke avec la guatrieme, le temps facteur. DePuis cette 6poque-la je me suis ori-en-be vers les quatre dimensions, vers les mouvements dans l'espace et le temps. -:tudiant les mouvements,les mouvements ventilatoires mesure par photogrammetrie le tronc humain.En projetant sur la surface du tronc un reseau quadratique, on pent compter de 3oo-400 points d'information, si un carre est 2 This 2 cm. Simultanement on pent ainsi contraler les deplacement relatifs des differents points. Travaillant avec seriophotographie et ces dernieres annees avec Video, nous avons des documents cDntinuellement en trois dimensions sun la position actuelle en espace de notre modele.On pent mesurer, reproduire la position momentan6e du sujet d'une frequence et dans la quantite desiree. Par exemple on peut les reproduire, une a une, comme une sculpture, en domontrant les changements d'un tronc humain pendant les mouvements respiratoires, comme nous avions fait en 1969 avec le sculpteur Istvan Bencsik en realisant nos differents modeles en inspiration et expiration.flais thooriquement on pent construire tant de sculptures qu'on vent entre les deux positions extremes.La methode est tres utilisable pour l'observation des mouvements sportifs on artistiques, comme le ballet par exemple. / Figure 1./ En etudiant en plusieures series la morphometrie des mouvements respiratoires on pent acquerir une certain experience, qui concerne la phase de respiration, on se trouve un corps humain sculpte, dessine on peint. Come le mimique d'un visage explkue toujours l'6tat affectif d'un individu, le corps humain peut expliquer tart des chases entre les mains d'un artiste doue. Liais nous retournerons encore a cet argument. Avec un objet d'art l'artiste registe un seul moment dune serie de mouvements de son sujet, spit en deux dimensions, s'il est peintre on graveur , dessinateur etc., spit en trois dimensions s'il est sculpteur.i:algre cela , il y a beaucoup d'oeuvresd'art dyna-miques, qui donnent l'impression de mouvement.On pent produire cet effetavec la ROMDOSi-tion des mouvements non simultanees , comme par exemple sur les tableaux de XIX 'si8cle representant des concours hyppiques, on les extremit-ees des chevaux sort distandue an maximum en avant et en arriere; c'est un mode de galop inexistant, mais malgr6, qu'il est faux, it suggere la vitesse.
Mechanisms of deterioration of nutrients. [of freeze dried foods
NASA Technical Reports Server (NTRS)
Karel, M.; Flink, J. M.
1976-01-01
Methods which produce freeze dried foods of improved quality were examined with emphasis on storage stability. Specific topics discussed include: microstructure of freeze dried systems, investigation of structural changes in freeze dried systems, artificial food matrices, osmotic preconcentration to yield improved quality freeze dried fruits, and storage stability of osmotically preconcentrated freeze dried fruits.
Shi, Zhihong; Zhu, Xiaomin; Zhang, Hongyi
2007-08-15
In this paper, a micelle-mediated extraction and cloud point preconcentration method was developed for the determination of less hydrophobic compounds aesculin and aesculetin in Cortex fraxini by HPLC. Non-ionic surfactant oligoethylene glycol monoalkyl ether (Genapol X-080) was employed as the extraction solvent. Various experimental conditions were investigated to optimize the extraction process. Under optimum conditions, i.e. 5% Genapol X-080 (w/v), pH 1.0, liquid/solid ratio of 400:1 (ml/g), ultrasonic-assisted extraction for 30 min, the extraction yield reached the highest value. For the preconcentration of aesculin and aesculetin by cloud point extraction (CPE), the solution was incubated in a thermostatic water bath at 55 degrees C for 30 min, and 20% NaCl (w/v) was added to the solution to facilitate the phase separation and increase the preconcentration factor during the CPE process. Compared with methanol, which was used in Chinese Pharmacopoeia (2005 edition) for the extraction of C. fraxini, the extraction efficiency of 5% Genapol X-080 reached higher value.
Takeda, Kazuhiko; Katoh, Shinya; Nakatani, Nobutake; Sakugawa, Hiroshi
2006-12-01
The aim of this research was to develop a simple procedure for a highly sensitive determination of low-molecular-weight (LMW) carbonyl compounds in drinking water and natural water. We employed a preconcentration HPLC system with 2,4-dinitrophenylhydrazine (DNPH) for the determination of LMW carbonyl compounds. A C-18 reverse-phase preconcentration column was used instead of a sample loop at the sample injection valve. A 0.1 - 5.0 mL portion of the derivatized sample solution was injected with a gas-tight syringe, and a 15% acetonitrile aqueous solution was pushed through the preconcentration column to remove the unreacted excess DNPH, which caused serious interference in the determination of formaldehyde. The detection limits were 1 - 3 nM with a relative standard deviation of 2 - 5% for 20 nM standard solutions (n = 5). The calibration curves were essentially unaffected by coexisting sea salts. Applications to commercial mineral water, tap water, river water, pond water and seawater are presented.
Ansari, Ashley J; Hai, Faisal I; Guo, Wenshan; Ngo, Hao H; Price, William E; Nghiem, Long D
2015-09-01
Forward osmosis (FO) can be used to extract clean water and pre-concentrate municipal wastewater to make it amenable to anaerobic treatment. A protocol was developed to assess the suitability of FO draw solutes for pre-concentrating wastewater for potential integration with anaerobic treatment to facilitate resource recovery from wastewater. Draw solutes were evaluated in terms of their ability to induce osmotic pressure, water flux, and reverse solute flux. The compatibility of each draw solute with subsequent anaerobic treatment was assessed by biomethane potential analysis. The effect of each draw solute (at concentrations corresponding to the reverse solute flux at ten-fold pre-concentration of wastewater) on methane production was also evaluated. The results show that ionic organic draw solutes (e.g., sodium acetate) were most suitable for FO application and subsequent anaerobic treatment. On the other hand, the reverse solute flux of inorganic draw solutions could inhibit methane production from FO pre-concentrated wastewater. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.
Azeem, Sami M Abdel; Hanafi, Hassan A; El-Shahat, M F
2015-01-01
A fast and sensitive on-line procedure for the determination of zinc in water and biological samples was developed. Zinc was preconcentrated in a mini-column packed with polyurethane foam (PUF) chemically modified with zincon via -N=N- bonding. The optimal conditions for preconcentration were pH 8.5 and sample flow rate of 4.0 mL min(-1). Quantitative desorption of Zn(II) was obtained by 0.1 mol L(-1) hydrochloric acid and subsequent spectrophotmetric determination using 4-(2-pyridylazo)-resorcinol at 498 nm. The obtained detection limit was found to be 3.0 ng mL(-1), precision (RSD) was 4.8 and 6.7% at 20 and 110 ng mL(-1), respectively, for 60 s preconcentration time and enrichment factor was 31. The linearity range was from 10 to 120 ng mL(-1) and maximum sample throughput was 20 h(-1). Finally, the method was successfully applied to the determination of zinc in tap water, Nile River water and human urine samples with RSD in the range of 1.1 - 8.3%.
Elimination des constantes arbitraires dans la theorie relativiste des quanta [85
NASA Astrophysics Data System (ADS)
This article shows how the influence of the undetermined constants in the integral theory of collisions1)2)3)4) can be avoided. A rule is given by which the probability amplitudes (5[F]-matrix) may be calculated in terms of a given local action. The procedure of the integral method differs essentially from the differential method employed by Tomonaga6), Schwikger5), FÅÕímaí7) and Dyson8) in that the two sorts of diverging terms occuring in the formal solution of a Schroedinqer equation are avoided. These two divergencies are: 1) the well known «.self energy» divergencies which have been since corrected by methods of regularization (Rivikr1), Pattli and Villaks9)); 2) the more serious boundary divergencies (Stueckelberg4)) due to the sharp spatio-temporal limitation of the space-time region of evolution V in which the collisions occur. The convergent parts (anomalous g-factor of the electron and the Lamb-Rethekford shift) obtained by Schwinger are, in the present theory, the boundary independent amplitudes in fourth approximation. Üp to this approximation the rule eliminates the arbitrary constants from all conservative processes.
Islam, Aminul; Ahmad, Hilal; Zaidi, Noushi; Kumar, Suneel
2014-08-13
A novel solid-phase extractant was synthesized by coupling graphene oxide (GO) on chloromethylated polystyrene through an ethylenediamine spacer unit to develop a column method for the preconcentration/separation of lead prior to its determination by flame atomic absorption spectrometry. It was characterized by Fourier transform infrared spectroscopy, far-infrared spectroscopy, thermogravimetric analysis/differential thermal analysis, scanning electron microscopy, energy-dispersive spectrometry, and transmission electron microscopy. The abundant oxygen-containing surface functional groups form a strong complex with lead, resulting in higher sorption capacity (227.92 mg g(-1)) than other nanosorbents used for sorption studies of the column method. Using the column procedure here is an alternative to the direct use of GO, which restricts irreversible aggregation of GO and its escape into the ecosystem, making it an environmentally sustainable method. The column method was optimized by varying experimental variables such as pH, flow rate for sorption/desorption, and elution condition and was observed to exhibit a high preconcentration factor (400) with a low preconcentration limit (2.5 ppb) and a high degree of tolerance for matrix ions. The accuracy of the proposed method was verified by determining the Pb content in the standard reference materials and by recovery experiments. The method showed good precision with a relative standard deviation <5%. The proposed method was successfully applied for the determination of lead in tap water, electroplating wastewater, river water, and food samples after preconcentration.
Bautista-Flores, Ana Nelly; De San Miguel, Eduardo Rodríguez; Gyves, Josefina de; Jönsson, Jan Åke
2011-08-18
Nickel (II) preconcentration and speciation analysis using a hollow fiber supported liquid membrane (HFSLM) device was studied. A counterflow of protons coupled to complexation with formate provided the driving force of the process, while Kelex 100 was employed as carrier. The influence of variables related to module configuration (acceptor pH and carrier concentration) and to the sample properties (donor pH) on the preconcentration factor, E, was simultaneously studied and optimized using a 3 factor Doehlert matrix response surface methodology. The effect of metal concentration was studied as well. Preconcentration factors as high as 4240 were observed depending on the values of the different variables. The effects of the presence of inorganic anions (NO2-, SO42-, Cl-, NO3-, CO32-, CN-) and dissolved organic matter (DOM) in the form of humic acids were additionally considered in order to carry out a speciation analysis study. Nickel preconcentration was observed to be independent of both effects, except when cyanide was present in the donor phase. A characterization of the transport regime was performed through the analysis of the dependence of E on the temperature. E increases with the increase in temperature according to the equation E(K) = -8617.3 + 30.5T with an activation energy of 56.7 kJ mol-1 suggesting a kinetic-controlled regime. Sample depletion ranged from 12 to 1.2% depending on the volume of the donor phase (100 to 1000 mL, respectively).
Tsoi, Yeuk-Ki; Leung, Kelvin Sze-Yin
2011-04-22
This paper describes a novel application of tetrabutylammonium hydroxide-modified activated carbon (AC-TBAH) to the speciation of ultra-trace Se(IV) and Se(VI) using LC-ICP-DRC-MS. The anion exchange functionality was immobilized onto the AC surface enables selective preconcentration of inorganic Se anions in a wide range of working pHs. Simultaneous retention and elution of both analytes, followed by subsequent analysis with LC-ICP-DRC-MS, allows to accomplish speciation analysis in natural samples without complicated redox pre-treatment. The laboratory-made column of immobilized AC (0.4 g of sorbent packed in a 6 mL syringe barrel) has achieved analyte enrichment factors of 76 and 93, respectively, for Se(IV) and Se(VI), thus proving its superior preconcentration efficiency and selectivity over common AC. The considerable enhancement in sensitivity achieved by using the preconcentration column has improved the method's detection limits to 1.9-2.2 ng L(-1), which is a 100-fold improvement compared with direct injection. The analyte recoveries from heavily polluted river matrix were between 95.3 and 107.7% with less than 5.0% RSD. The robustness of the preconcentration and speciation method was validated by analysis of natural waters collected from rivers and reservoirs in Hong Kong. The modified AC material is hence presented as a low-cost yet robust substitute for conventional anion exchange resins for routine applications. Copyright © 2011 Elsevier B.V. All rights reserved.
Yanagisawa, Naoki; Dutta, Debashis
2012-08-21
In this Article, we describe a microfluidic enzyme-linked immunosorbent assay (ELISA) method whose sensitivity can be substantially enhanced through preconcentration of the target analyte around a semipermeable membrane. The reported preconcentration has been accomplished in our current work via electrokinetic means allowing a significant increase in the amount of captured analyte relative to nonspecific binding in the trapping/detection zone. Upon introduction of an enzyme substrate into this region, the rate of generation of the ELISA reaction product (resorufin) was observed to increase by over a factor of 200 for the sample and 2 for the corresponding blank compared to similar assays without analyte trapping. Interestingly, in spite of nonuniformities in the amount of captured analyte along the surface of our analysis channel, the measured fluorescence signal in the preconcentration zone increased linearly with time over an enzyme reaction period of 30 min and at a rate that was proportional to the analyte concentration in the bulk sample. In our current study, the reported technique has been shown to reduce the smallest detectable concentration of the tumor marker CA 19-9 and Blue Tongue Viral antibody by over 2 orders of magnitude compared to immunoassays without analyte preconcentration. When compared to microwell based ELISAs, the reported microfluidic approach not only yielded a similar improvement in the smallest detectable analyte concentration but also reduced the sample consumption in the assay by a factor of 20 (5 μL versus 100 μL).
NASA Astrophysics Data System (ADS)
Chabot, Vincent
L'elaboration de nouveaux medicaments repose sur les etudes pharmacologiques, dont le role est d'identifier de nouveaux composes actifs ou de nouvelles cibles pharmacologiques agissant entre autres au niveau cellulaire. Recemment, la detection basee sur la resonance des plasmons de surface (SPR) a ete appliquee a l'etude de reponses cellulaires. Cette methode de detection, permettant d'observer des variations d'indice de refraction associes a de faibles changements de masse a la surface d'un metal, a l'avantage de permettre l'etude d'une population de cellules vivantes en temps reel, sans necessiter l'introduction d'agents de marquage. Pour effectuer la detection au niveau de cellules individuelles, on peut employer la microscopie SPR, qui consiste a localiser spatialement la detection par un systeme d'imagerie. Cependant, la detection basee sur la SPR est une mesure sans marquage et les signaux mesures sont attribues a une reponse moyennee des differentes sources cellulaires. Afin de mieux comprendre et identifier les composantes cellulaires generant le signal mesure en SPR, il est pertinent de combiner la microscopie SPR avec une modalite complementaire, soit l'imagerie de fluorescence. C'est dans cette problematique que s'insere ce projet de these, consistant a concevoir deux plates-formes distinctes de microscopie SPR et de fluorescence optimisees pour l'etude cellulaire, de sorte a evaluer les possibilites d'integration de ces deux modalites en un seul systeme. Des substrats adaptes pour chaque plate-forme ont ete concus et realises. Ces substrats employaient une couche d'argent passivee par l'ajout d'une mince couche d'or. La stabilite et la biocompatibilite des substrats ont ete validees pour l'etude cellulaire. Deux configurations permettant d'ameliorer la sensibilite en sondant les cellules plus profondement ont ete evaluees, soit l'emploi de plasmons de surface a longue portee et de guides d'onde a gaine metallique. La sensibilite accrue de ces configurations a aussi ete demontree pour un usage en biodetection cellulaire. Une plate-forme permettant de mesurer la spectroscopie SPR simultanement avec l'acquisition d'images de fluorescence a ete realisee. Cette plate-forme a ensuite ete validee par l'etude de reponses cellulaires suite a une stimulation pharmacologique. Puis, un systeme base sur la microscopie SPR a ete concu et caracterise. Son emploi pour l'etude de reponses au niveau de cellules individuelles a ete demontre. Finalement, les forces et faiblesses des substrats et des plates-formes realisees au cours de la these ont ete evaluees. Des possibilites d'amelioration sont mises de l'avant et l'integration des modalites de microscopie SPR et de fluorescence suite aux travaux de la these est discutee. Les realisations au cours de cette etude ont donc permis d'identifier les composantes cellulaires impliquees dans la generation du signal mesure en biodetection SPR. Mots-cles : Resonance des plasmons de surface, microscopie SPR, plasmons de surface a longue portee LRSPR, guide d'onde a gaine metallique MCWG, fluorescence exaltee par plasmons de surface SPEF, biodetection cellulaire, imagerie SPR.
Methods for improved preconcentrators
Manginell, Ronald P [Albuquerque, NM; Lewis, Patrick R [Albuquerque, NM; Okandan, Murat [Edgewood, NM
2010-06-01
The present invention relates generally to chemical analysis (e.g. by gas chromatography), and in particular to a compact chemical preconcentrator formed on a substrate with a heatable sorptive membrane that can be used to accumulate and concentrate one or more chemical species of interest over time and then rapidly release the concentrated chemical species upon demand for chemical analysis.
A method for the detection of trace levels of N,N-diethyl-m-toluamide (DEET) in water is discussed. The method utilizes an on-line preconcentration column in series with high performance liquid chromatography (HPLC) and UV photodiode array detection. DEET, a common insect repel...
Bautista-Flores, Ana Nelly; de San Miguel, Eduardo Rodríguez; de Gyves, Josefina; Jönsson, Jan Åke
2011-01-01
Nickel (II) preconcentration and speciation analysis using a hollow fiber supported liquid membrane (HFSLM) device was studied. A counterflow of protons coupled to complexation with formate provided the driving force of the process, while Kelex 100 was employed as carrier. The influence of variables related to module configuration (acceptor pH and carrier concentration) and to the sample properties (donor pH) on the preconcentration factor, E, was simultaneously studied and optimized using a 3 factor Doehlert matrix response surface methodology. The effect of metal concentration was studied as well. Preconcentration factors as high as 4240 were observed depending on the values of the different variables. The effects of the presence of inorganic anions (NO2−, SO42−, Cl−, NO3−, CO32−, CN−) and dissolved organic matter (DOM) in the form of humic acids were additionally considered in order to carry out a speciation analysis study. Nickel preconcentration was observed to be independent of both effects, except when cyanide was present in the donor phase. A characterization of the transport regime was performed through the analysis of the dependence of E on the temperature. E increases with the increase in temperature according to the equation E(K) = −8617.3 + 30.5T with an activation energy of 56.7 kJ mol−1 suggesting a kinetic-controlled regime. Sample depletion ranged from 12 to 1.2% depending on the volume of the donor phase (100 to 1000 mL, respectively). PMID:24957733
Kara, Derya; Fisher, Andrew; Hill, Steve J
2009-06-15
A matrix separation and analyte preconcentration system using Amberlite XAD copolymer resins functionalized by Schiff base reactions coupled with atomic spectrometry has been developed. Three different functionalized Amberlite XAD resins were synthesized using 4-phenylthiosemicarbazide, 2,3-dihydroxybenzaldehyde and 2-thiophenecarboxaldehyde as reagents. These resins could be used to preconcentrate transition and other trace heavy metal analytes from nitric acid digests of soil and sediment samples. Analyte retention was shown to work well at pH 6.0. After treatment of the digests with sodium fluoride and buffering to pH 6, samples that contain extremely large concentrations of iron were analysed for trace analytes without the excess iron overloading the capacity of the resin. The analytes Cd, Co, Cu, Ni and Pb were preconcentrated from acid extracts of certified soil/sediment samples and then eluted with 0.1M HNO(3) directly to the detection system. Flame atomic absorption spectrometry was used as a means of detection during the studies. The efficiency of the chelating resin and the accuracy of the proposed method were evaluated by the analysis of soil (SO-2) and sediment (LGC 6157 and MESS-3) certified reference materials.
NASA Astrophysics Data System (ADS)
Duan, Taicheng; Song, Xuejie; Xu, Jingwei; Guo, Pengran; Chen, Hangting; Li, Hongfei
2006-09-01
Using a solid phase extraction mini-column home-made from a neutral extractant Cyanex 923, inorganic Hg could be on-line preconcentrated and simultaneously separated from methyl mercury. The preconcentrated Hg (II) was then eluted with 10% HNO 3 and subsequently reduced by NaBH 4 to form Hg vapor before determination by cold vapor atomic absorption spectrometry (CVAAS). Optimal conditions for and interferences on the Hg preconcentration and measurement were at 1% HCl, for a 25 mL sample uptake volume and a 10 mL min - 1 sample loading rate. The detection limit was 0.2 ng L - 1 and much lower than that of conventional method (around 15.8 ng L - 1 ). The relative standard deviation (RSD) is 1.8% for measurements of 40 ng L - 1 of Hg and the linear working curve is from 20 to 2000 ng L - 1 (with a correlation coefficient of 0.9996). The method was applied in determination of inorganic Hg in city lake and deep well water (from Changchun, Jilin, China), and recovery test results for both samples were satisfactory.
Concurrent DNA Preconcentration and Separation in Bipolar Electrode-Based Microfluidic Device
Song, Hongjun; Wang, Yi; Garson, Charles; Pant, Kapil
2015-01-01
This paper presents a bipolar electrode (BPE) device in a microfluidic dual-channel design for concurrent preconcentration and separation of composite DNA containing samples. The novelty of the present effort relies on the combination of BPE-induced ion concentration polarization (ICP) and end-labeled free-solution electrophoresis (ELFSE). The ion concentration polarization effect arising from the faradaic reaction on the BPE is utilized to exert opposing electrophoretic and electroosmotic forces on the DNA samples. Meanwhile, end-labeled free-solution electrophoresis alters the mass-charge ratio to enable simultaneous DNA separation in free solution. The microfluidic device was fabricated using standard and soft lithography techniques to form gold-on-glass electrode capped with a PDMS microfluidic channel. Experimental testing with various DNA samples was carried out over a range of applied electric field. Concentration ratios up to 285× within 5 minutes for a 102-mer DNA, and concurrent preconcentration and free-solution separation of binary mixture of free and bound 102-mer DNA within 6 minutes was demonstrated. The effect of applied electric field was also interrogated with respect to pertinent performance metrics of preconcentration and separation. PMID:26005497
Determination of simazine in water samples by HPLC after preconcentration with diatomaceous earth.
Katsumata, Hideyuki; Fujii, Aya; Kaneco, Satoshi; Suzuki, Tohru; Ohta, Kiyohisa
2005-01-15
A sensitive and selective batch adsorption method is proposed for the preconcentration and determination of simazine. Simazine was preconcentrated on diatomaceous earth as an adsorbent and then determined by high-performance liquid chromatography (HPLC). Several parameters on the recovery of the analyte were investigated. The experimental results showed that it was possible to obtain quantitative analysis when the solution pH was 2 using 100mL of validation solution containing 1.5mug of simazine and 5mL of ethanol as an eluent. Recovery of simazine was 89.0 +/- 1.6% with a relative standard deviation for seven determinations of 1.5% under optimum conditions. The maximum preconcentration factor was 100 for simazine when 500mL of sample solution volume was used. The linear range of calibration curve was 1-200ngmL(-1) with a correlation coefficient of 0.996 and the detection limit (3S/N) was 0.3ngmL(-1). The capacity of the adsorbent was also examined and found to be 1.1mgg(-1) for simazine. The proposed method was successfully applied to the determination of simazine in river water with high precision and accuracy.
Martinis, Estefanía M; Bertón, Paula; Olsina, Roberto A; Altamirano, Jorgelina C; Wuilloud, Rodolfo G
2009-08-15
A liquid-liquid extraction procedure (L-L) based on room temperature ionic liquid (RTIL) was developed for the preconcentration and determination of mercury in different water samples. The analyte was quantitatively extracted with 1-butyl-3-methylimidazolium hexafluorophosphate ([C(4)mim][PF(6)]) under the form of Hg-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (Hg-5-Br-PADAP) complex. A volume of 500 microl of 9.0 mol L(-1) hydrochloric acid was used to back-extract the analyte from the RTIL phase into an aqueous media prior to its analysis by flow injection-cold vapor atomic absorption spectrometry (FI-CV-AAS). A preconcentration factor of 36 was achieved upon preconcentration of 20 mL of sample. The limit of detection (LOD) obtained under the optimal conditions was 2.3ngL(-1) and the relative standard deviation (RSD) for 10 replicates at 1 microg L(-1) Hg(2+) was 2.8%, calculated with peaks height. The method was successfully applied to the determination of mercury in river, sea, mineral and tap water samples and a certified reference material (CRM).
Feist, Barbara; Mikula, Barbara
2014-03-15
A method of separation and preconcentration of cadmium, cobalt, copper, nickel, lead, and zinc at trace level using activated carbon is proposed. Activated carbon with the adsorbed trace metals was mineralised using a high-pressure microwave mineraliser. The heavy metals were determined after preconcentration by inductively coupled plasma optical emission spectrometry (ICP-OES). The influence of several parameters, such as pH, sorbent mass, shaking time was examined. Moreover, effects of inorganic matrix on recovery of the determined elements were studied. The experiment shows that foreign ions did not influence recovery of the determined elements. The detection limits (DL) of Cd, Co, Cu, Ni, Pb, and Zn were 0.17, 0.19, 1.60, 2.60, 0.92 and 1.50 μg L(-)(1), respectively. The recovery of the method for the determined elements was better than 95% with relative standard deviation from 1.3% to 3.7%. The preconcentration factor was 80. The proposed method was applied for determination of Cd, Co, Cu, Ni, Pb, and Zn in fruits materials. Accuracy of the proposed method was verified using certified reference material (NCS ZC85006 Tomato). Copyright © 2013 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Vassileva, Emilia; Wysocka, Irena
2016-12-01
Anthropogenic Pb in the oceans, derived from high-temperature industrial processes, fuel combustion and incineration can have an isotopic signature distinct from naturally occurring Pb, supplied by rock weathering. To identify the different pollution sources accurately and to quantify their relative contributions, Pb isotope ratios are widely used. Due to the high salt content (approximately 3.5% of total dissolved solids) and very low levels of Pb (typically from 1 to 100 ng L- 1) in seawater the determination of Pb isotope ratios requires preliminary matrix separation and analyte preconcentration. An analytical protocol for the measurements of Pb isotope ratios in seawater combining seaFAST sample pre-treatment system and Sector Field Inductively Coupled Plasma Mass Spectrometry (SF ICP-MS) was developed. The application of seaFAST system was advantageous, because of its completely closed working cycle and small volumes of chemicals introduced in pre-treatment step, resulting in very low detection limits and procedural blanks. The preconcentration/matrix separation step was also of crucial importance for minimizing the isobaric and matrix interferences, coming from the seawater. In order to differentiate between anthropogenic and natural Pb sources, particular attention was paid to the determination of 204Pb isotope because of its implication in some geological interpretations. The validation of the analytical procedure was effectuated according to the recommendations of the ISO/IEC 17025 standard. The method was validated by processing the common Pb isotope reference material NIST SRM 981. All major sources of uncertainty were identified and propagated together following the ISO/GUM guidelines. The estimation of the total uncertainty associated to each measurement result was fundamental tool for sorting the main sources of possible biases. The developed analytical procedure was applied to the coastal and open seawater samples, collected in different regions of the world and revealed that the procedure is applicable for the measurement of Pb isotope ratios in seawater with combined uncertainty adequate to discuss the origin of Pb pollution in the ocean.
Kazemipur, Abdolmohammad
2016-11-01
In much of the academic debate on the integration of Muslims into Western liberal democracies, Islam is often treated as one or the sole independent variable in the lives of Muslims. Offering to view Islam-or the understanding of Islam among Muslims-as the dependent variable, The Muslim Question in Canada discusses the influence of socioeconomic forces in shaping the Muslim immigrants' opinions, modes of thinking, and even interpretations of their faith. Drawing on this general approach, which is introduced and developed in the book using a variety of both quantitative and qualitative data, this article focuses on a school of thought within the Islamic jurisprudence known as fiqh al-aqalliyyat al-Muslema (the jurisprudence of Muslim minorities). The premise of the jurisprudence of Muslim minorities is that the lived realities of Muslims who reside in non-Muslim countries are so fundamentally different from those of the Muslim-majority nations that traditional Islamic jurisprudence cannot offer meaningful solutions for their problems. Therefore, there is a need to establish an entirely different jurisprudential approach centered around the lives of the Muslim minorities. The purpose of the bulk of jurisprudential theorization efforts in this line of reasoning is to facilitate the lives of the Muslim minorities; as well, they aim to create a foundation for the moral obligations of Muslims toward non-Muslims in such environments. I argue that a crucial element that triggers such a development is the existence of a positive relationship between Muslims and non-Muslims in immigrant-receiving countries. Souvent au sein des débats sur l'intégration des Musulmans dans des démocraties libérales de l'Ouest, l'Islam est traité comme un ou le seul enjeu dans la vie des fidèles. The Muslim Question in Canada examine l'Islam ou la compréhension de l'Islam chez les Musulmans comme un enjeu dépendent et aborde l'influence des forces socio-économiques sur les opinons des immigrants musulmans ainsi que sur leurs modes de pensée et même sur la manière dont ils interprètent leur foi. Inspiré par cette approche, que l'on présente et développe dans le livre, et qui se sert de données à la fois quantitatives et qualitatives, cet article se concentre sur une école de pensée à l'intérieur de la jurisprudence islamique, connue sous le nom de fiqh al aqalliyyat al-Muslema (la jurisprudence des minorités musulmanes). La prémisse de la jurisprudence des minorités musulmanes est que les réalités vécues par les Musulmans qui vivent dans des pays non-musulmans sont au fond tellement différentes de celles de la majorité musulmane que la jurisprudence traditionnelle ne présente pas de solutions pertinentes pour résoudre leurs problèmes. Ainsi, il faut établir une approche jurisprudentielle totalement différente, axée sur la vie des minorités musulmanes. L'objectif de la plupart des efforts au niveau de la théorisation de la jurisprudence qui adoptent cette vision est de rendre la vie des minorités musulmanes plus facile. Ces efforts tentent aussi de faire en sorte que les Musulmans ressentent une certaine obligation morale envers les non-Musulmans dans ces environnements. J'avance ici que l'aspect qui déclenche un tel développement est le rapport positif entre les Musulmans et les non-Musulmans dans les pays qui reçoivent des immigrants. © 2016 Canadian Sociological Association/La Société canadienne de sociologie.
NASA Astrophysics Data System (ADS)
Chepigin, A.; Leonte, M.; Colombo, F.; Kessler, J. D.
2014-12-01
Dissolved methane, ethane, propane, and butane concentrations in natural waters are traditionally measured using a headspace equilibration technique and gas chromatograph with flame ionization detector (GC-FID). While a relatively simple technique, headspace equilibration suffers from slow equilibration times and loss of sensitivity due to concentration dilution with the pure gas headspace. Here we present a newly developed pre-concentration system and auto-analyzer for use with a GC-FID. This system decreases the time required for each analysis by eliminating the headspace equilibration time, increases the sensitivity and precision with a rapid pre-concentration step, and minimized operator time with an autoanalyzer. In this method, samples are collected from Niskin bottles in newly developed 1 L plastic sample bags rather than glass vials. Immediately following sample collection, the sample bags are placed in an incubator and individually connected to a multiport sampling valve. Water is pumped automatically from the desired sample bag through a small (6.5 mL) Liqui-Cel® membrane contactor where the dissolved gas is vacuum extracted and directly flushed into the GC sample loop. The gases of interest are preferentially extracted with the Liqui-Cel and thus a natural pre-concentration effect is obtained. Daily method calibration is achieved in the field with a five-point calibration curve that is created by analyzing gas standard-spiked water stored in 5 L gas-impermeable bags. Our system has been shown to substantially pre-concentrate the dissolved gases of interest and produce a highly linear response of peak areas to dissolved gas concentration. The system retains the high accuracy, precision, and wide range of measurable concentrations of the headspace equilibration method while simultaneously increasing the sensitivity due to the pre-concentration step. The time and labor involved in the headspace equilibration method is eliminated and replaced with the immediate and automatic analysis of a maximum of 13 sequential samples. The elapsed time between sample collection and analysis is reduced from approximately 12 hrs to < 10 min, enabling dynamic and highly resolved sampling plans.
Hong, Sung A; Kim, Yong-June; Kim, Sung Jae; Yang, Sung
2018-06-01
DNA methylation is considered to be a promising marker for the early diagnosis and prognosis of cancer. However, direct detection of the methylated DNAs in clinically relevant samples is still challenging because of its extremely low concentration (~fM). Here, an integrated microfluidic chip is reported, which is capable of pre-concentrating the methylated DNAs using ion concentration polarization (ICP) and electrochemically detecting the pre-concentrated DNAs on a single chip. The proposed chip is the first demonstration of an electrochemical detection of both level and concentration of the methylated DNAs by integrating a DNA pre-concentration unit without gene amplification. Using the proposed chip, 500 fM to 500 nM of methylated DNAs is pre-concentrated by almost 100-fold in 10 min, resulting in a drastic improvement of the electrochemical detection threshold down to the fM level. The proposed chip is able to measure not only the DNA concentration, but also the level of methylation using human urine sample by performing a consecutive electrochemical sensing on a chip. For clinical application, the level as well as the concentration of methylation of glutathione-S transferase-P1 (GSTP1) and EGF-containing fibulin-like extracellular matrix protein 1 (EFEMP1), which are known to be closely associated with prostate cancer diagnosis, are electrochemically detected in human urine spiked with these genes. The developed chip shows a limit of detection (LoD) of 7.9 pM for GSTP1 and 11.8 pM for EFEMP1 and is able to detect the level of methylation in a wide range from 10% to 100% with the concentration variation from 50 pM to 500 nM. Copyright © 2018 Elsevier B.V. All rights reserved.
Arslan, Z; Paulson, A J
2002-04-01
The aragonite deposits within the ear bones (otoliths) of teleost fish retain a chemical signal reflecting the life history of fish (similar to rings of trees) and the nature of fish habitats. Otoliths dissolved in acid solutions contain high concentrations of calcium and a variety of proteins. Elimination of matrix salts and organic interferences during preconcentration is essential for accurate determination of trace elements in otolith solutions by inductively coupled plasma-quadrupole mass spectrometry. An iminodiacetate-based chelating resin (Toyopearl AF-Chelate 650 M) has been used for on-line preconcentration and matrix separation for the determination of 31 transition and rare elements. Successful preconcentration of the elements was achieved at pH 5 by on-line buffering, except Mn which required pH 8.8. Sample solutions were loaded on to the column for 1 min at 3.2 mL min(-1), and then eluted directly into the mass spectrometer with 4% v/v nitric acid. This procedure enabled up to 25-fold preconcentration with successful removal of the calcium matrix. The effect of heat-assisted oxidation with concentrated nitric acid was investigated to eliminate the organic matrix. It was found that heating to dryness after dissolution and further mineralization with the acid significantly improved the retention of the transition elements. The method was validated by analysis of a certified reference material produced from saggittal otoliths of emperor snapper ( Lutjanus sebae), and then applied to the determination of trace metal concentrations in juvenile bluefin tuna ( Thunnus thynnus) from the Western Pacific Ocean.
Cortez, Juliana; Pasquini, Celio
2013-02-05
The ring-oven technique, originally applied for classical qualitative analysis in the years 1950s to 1970s, is revisited to be used in a simple though highly efficient and green procedure for analyte preconcentration prior to its determination by the microanalytical techniques presently available. The proposed preconcentration technique is based on the dropwise delivery of a small volume of sample to a filter paper substrate, assisted by a flow-injection-like system. The filter paper is maintained in a small circular heated oven (the ring oven). Drops of the sample solution diffuse by capillarity from the center to a circular area of the paper substrate. After the total sample volume has been delivered, a ring with a sharp (c.a. 350 μm) circular contour, of about 2.0 cm diameter, is formed on the paper to contain most of the analytes originally present in the sample volume. Preconcentration coefficients of the analyte can reach 250-fold (on a m/m basis) for a sample volume as small as 600 μL. The proposed system and procedure have been evaluated to concentrate Na, Fe, and Cu in fuel ethanol, followed by simultaneous direct determination of these species in the ring contour, employing the microanalytical technique of laser induced breakdown spectroscopy (LIBS). Detection limits of 0.7, 0.4, and 0.3 μg mL(-1) and mean recoveries of (109 ± 13)%, (92 ± 18)%, and (98 ± 12)%, for Na, Fe, and Cu, respectively, were obtained in fuel ethanol. It is possible to anticipate the application of the technique, coupled to modern microanalytical and multianalyte techniques, to several analytical problems requiring analyte preconcentration and/or sample stabilization.
Comparisons of GLM and LMA Observations
NASA Astrophysics Data System (ADS)
Thomas, R. J.; Krehbiel, P. R.; Rison, W.; Stanley, M. A.; Attanasio, A.
2017-12-01
Observations from 3-dimensional VHF lightning mapping arrays (LMAs) provide a valuable basis for evaluating the spatial accuracy and detection efficiencies of observations from the recently launched, optical-based Geosynchronous Lightning Mapper (GLM). In this presentation, we describe results of comparing the LMA and GLM observations. First, the observations are compared spatially and temporally at the individual event (pixel) level for sets of individual discharges. For LMA networks in Florida, Colorado, and Oklahoma, the GLM observations are well correlated time-wise with LMA observations but are systematically offset by one- to two pixels ( 10 to 15 or 20 km) in a southwesterly direction from the actual lightning activity. The graphical comparisons show a similar location uncertainty depending on the altitude at which the scattered light is emitted from the parent cloud, due to being observed at slant ranges. Detection efficiencies (DEs) can be accurately determined graphically for intervals where individual flashes in a storm are resolved time-wise, and DEs and false alarm rates can be automated using flash sorting algorithms for overall and/or larger storms. This can be done as a function of flash size and duration, and generally shows high detection rates for larger flashes. Preliminary results during the May 1 2017 ER-2 overflight of Colorado storms indicate decreased detection efficiency if the storm is obscured by an overlying cloud layer.
Preconcentration and separation of analytes in microchannels
Hatch, Anson; Singh, Anup K.; Herr, Amy E.; Throckmorton, Daniel J.
2010-11-09
Disclosed herein are methods and devices for preconcentrating and separating analytes such as proteins and polynucleotides in microchannels. As disclosed, at least one size-exclusion polymeric element is adjacent to processing area or an assay area in a microchannel which may be porous polymeric element. The size-exclusion polymeric element may be used to manipulate, e.g. concentrate, analytes in a sample prior to assaying in the assay area.
NASA Astrophysics Data System (ADS)
Pérez-Corona, Teresa; Madrid-Albarrán, Yolanda; Cámara, Carmen; Beceiro, Elisa
1998-02-01
The use of living organisms for metal preconcentration and speciation is discussed. Among substrates, Saccharomyces cerevisiae baker's yeast has been successfully used for the speciation of mercury [Hg(II) and CH 3Hg +], selenium [Se(IV) and Se(VI)] and antimony [Sb(III) and Sb(V)]. To illustrate the capabilities of these organisms, the analytical performance of baker's yeast immobilized on silica gel for on-line preconcentration and speciation of Hg(II) and methylmercury is reported. The immobilized cells were packed in a PTFE microcolumn, through which mixtures of organic and inorganic mercury solutions were passed. Retention of inorganic and organic mercury solutions took place simultaneously, with the former retained in the silica and the latter on the yeast. The efficiency uptake for both species was higher than 95% over a wide pH range. The speciation was carried out by selective and sequential elution with 0.02 mol L -1 HCl for methylmercury and 0.8 mol L -1 CN - for Hg(II). This method allows both preconcentration and speciation of mercury. The preconcentration factors were around 15 and 100 for methylmercury and mercury(II), respectively. The method has been successfully applied to spiked sea water samples.
Zhang, Yaohai; Jiao, Bining
2013-09-01
A fast and simple technique composed of dispersive liquid-liquid microextraction (DLLME) and online preconcentration MEKC with diode array detection was developed for the determination of four phenoxyacetic acids, 2,4,5-trichlorophenoxyacetic acid, 2,4-dichlorophenoxyacetic acid, 2,6-dichlorophenoxyacetic acid, and 4-chlorophenoxyacetic acid, in drinking water. The four phenoxyacetic acids were separated in reversed-migration MEKC to the baseline. About 145-fold increases in detection sensitivity were observed with online concentration strategy, compared with standard hydrodynamic injection (5 s at 25 mbar pressure). LODs ranged from 0.002 to 0.005 mg/L using only the online preconcentration procedures without any offline concentration of the extract. A DLLME procedure was used in combination with the proposed online preconcentration strategies, which achieved the determination of analytes at limits of quantification ranging from 0.2 to 0.5 μg/kg, which is far lower than the maximum residue limits established by China. The satisfactory recoveries obtained by DLMME spiked at two levels ranged from 67.2 to 99.4% with RSD <15%, making this proposed method suitable for the determination of phenoxyacetic acids in water samples. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Shiralipour, Roohollah; Larki, Arash
2017-01-01
In this study, a new absorbent based on cellulose nanosponges modified with methyltrioctylammonium chloride (aliquat 336) was prepared and used for pre-concentration, removal and determination of tartrazine dye, using UV-vis spectrophotometry. This adsorbent was fully characterized using various instrumental techniques such as SEM, FTIR and XRD spectra. The pre-concentration and removal procedures were studied in column and batch modes, respectively. The effects of parameters such as pH of the aqueous medium, methyltrioctylammounium chloride dose, adsorbent amount, desorbing conditions and interfering ions on the adsorption of tartrazine were investigated and optimized. The fitting experimental data with conventional isotherm models revealed that the adsorption followed the Brunauer-Emmett-Teller (BET) model and the maximum adsorption capacity for tartrazine was 180mg/g with modified nanosponges. Under the optimized conditions, the calibration curve was linear over the range of 2-300ng/mL and the limit of detection was 0.15ng/mL. The relative standard deviation (RSD) for 20 and 100ng/mL of tartrazine were 3.1% and 1.5%, respectively. The proposed method was applied for pre-concentration and determination of tartrazine dye in different water samples. Copyright © 2016 Elsevier Inc. All rights reserved.
Wilson, Walter B; Costa, Andréia A; Wang, Huiyong; Dias, José A; Dias, Sílvia C L; Campiglia, Andres D
2012-07-06
The analytical performance of BEA - a commercial zeolite - is evaluated for the pre-concentration of fifteen Environmental Protection Agency - polycyclic aromatic hydrocarbons and their subsequent HPLC analysis in tap and lake water samples. The pre-concentration factors obtained with BEA have led to a method with excellent analytical figures of merit. One milliliter aliquots were sufficient to obtain excellent precision of measurements at the parts-per-trillion concentration level with relative standard deviations varying from 4.1% (dibenzo[a,h]anthracene) to 13.4% (pyrene). The limits of detection were excellent as well and varied between 1.1 (anthracene) and 49.9 ng L(-1) (indeno[1,2,3-cd]pyrene). The recovery values of all the studied compounds meet the criterion for regulated polycyclic aromatic hydrocarbons, which mandates relative standard deviations equal or lower than 25%. The small volume of organic solvents (100 μL per sample) and amount of BEA (2 mg per sample) makes sample pre-concentration environmentally friendly and cost effective. The extraction procedure is well suited for numerous samples as the small working volume (1 mL) facilitates the implementation of simultaneous sample extraction. These are attractive features when routine monitoring of numerous samples is contemplated. Copyright © 2012 Elsevier B.V. All rights reserved.
Shamsipur, Mojtaba; Yazdanfar, Najmeh; Ghambarian, Mahnaz
2016-08-01
In this work, an effective preconcentration method for the extraction and determination of traces of multi-residue pesticides was developed using solid-phase extraction (SPE) coupled with dispersive liquid-liquid microextraction and gas chromatography-mass spectrometry (GC-MS). Variables affecting the performance of both extraction steps such as type and volume of elution and extraction solvents, breakthrough volume, salt addition, extraction time were thoroughly investigated. The proposed method resulted in good linearities (R(2)>0.9915) over the ranges of 1-10,000ngkg(-1), limits of detection (LODs) in the range of 0.5-1.0ngkg(-1) at S/N=3, and precision of RSD% of ⩽11.8. Under optimal conditions, the preconcentration factors were obtained in the range of 2362-10,593 for 100mL sample solutions. Comparison of the proposed method with other ones demonstrated that SPE-DLLME method provides higher extraction efficiency and larger preconcentration factor for determination of pesticides residues. Further, it is simple, inexpensive, highly sensitive, and can be successfully applied to separation, preconcentration and determination of the pesticides (and other noxious materials) in different real food samples. Copyright © 2016 Elsevier Ltd. All rights reserved.
Ghaedi, M; Tavallali, H; Montazerozohori, M; Zahedi, E; Amirineko, M; Khodadoust, S; Karimipour, G
2012-11-01
In this work, two N/S-containing chelating agents 2-(4-methoxybenzylideneamino)thiophenol (2-4-MBAT) and 2-(4-chlorobenzylideneamino) benzenethiol (2-4-CBABT) were synthesized as new sorbents and were used for preconcentration of Zn(2+) and Cu(2+) ions in food and vegetable samples. In the proposed procedure, the trace amount of Zn(2+) and Cu(2+) ions from 250 mL of sample solution at pH = 5.0 was preconcentrated by 1 g of activated carbon (AC) loaded with 15 mg of 2-4-MBAT and 2-4-CBABT separately. The breakthrough volumes (maximum sample volume that their metal ions quantitatively can be enriched) for solid-phase extraction (SPE) procedure based on the AC modified with 2-4-MBAT and 2-4-CBABT were 800 and 750 mL, respectively. The sorbed Zn(2+) and Cu(2+) ions were efficiently eluted by 8 mL of 4 mol L(-1) HNO(3) and preconcentration factor of 112.5 and 93.7 and experimental enhancement factor of 30 and 35 ions were obtained for Zn(2+) and Cu(2+), respectively. The application of this enrichment procedure allowed the extraction of trace metal ions with recoveries exceeding of 90%.
NASA Astrophysics Data System (ADS)
Guhathakurta, Puragra; Toloba, Elisa; Peng, Eric W.; Li, Biao; Gwyn, Stephen; Ferrarese, Laura; Cote, Patrick; Chu, Jason; Sparkman, Lea; Chen, Stephanie; Yagati, Samyukta; Muller, Meredith; Next Generation Virgo Survey Collaboration
2015-01-01
We present results from an ongoing study of globular cluster (GC) satellites of low-luminosity dwarf elliptical (dE) galaxies in the Virgo cluster. Our 21 dE targets and candidate GC satellites around them in the apparent magnitude range g ~ 20-24 were selected from the Next Generation Virgo Survey (NGVS) and followed up with medium-resolution Keck/DEIMOS spectroscopy (resolving power: R ~ 2000; wavelength coverage: 4800-9500 Angstrom). In addition, the remaining space available on the nine DEIMOS multi-slit masks were populated with "filler" targets in the form of distant Milky Way halo star candidates in a comparable apparent magnitude range. A combination of radial velocity information (measured from the Keck/DEIMOS spectra), color-color information (from four-band NGVS photometry), and sky position information was used to sort the sample into the following categories: (1) GC satellites of dEs, (2) other non-satellite GCs in the Virgo cluster (we dub them "orphan" GCs), (3) foreground Milky Way stars that are members of the Sagittarius stream, the Virgo overdensity, or the field halo population, and (4) distant background galaxies. We stack the GC satellite population across all 21 host dEs and carry out dynamical modeling of the stacked sample in order to constrain the average mass of dark matter halos that these dEs are embedded in. We study rotation in the system of GC satellites of dEs in the handful of more populated systems in our sample - i.e., those that contain 10 or more GC satellites per dE. A companion AAS poster presented at this meeting (Chu, J. et al. 2015) presents chemical composition and age constraints for these GC satellites relative to the nuclei of the host dEs based on absorption line strengths in co-added spectra. The orphan GCs are likely to be intergalactic GCs within the Virgo cluster (or, equivalently, GCs in the remote outer envelope of the cluster's central galaxy, the giant elliptical M87).This project is funded in part by the National Science Foundation. Some of this research was conducted by high-school students working under the auspices of the Science Internship Program at the University of California Santa Cruz.
Wiemer, Marcus; Stoikovic, Sinisa; Samol, Alexander; Dimitriadis, Zisis; Ruiz-Nodar, Juan M; Birkemeyer, Ralf; Monsegu, Jacques; Finet, Gérard; Hildick-Smith, David; Tresukosol, Damras; Novo, Enrique Garcia; Koolen, Jacques J; Barbato, Emanuele; Danzi, Gian Battista
2017-02-10
To report the long-term safety and efficacy data of a third generation drug eluting stent (DES) with biodegradable polymer in the complex patient population of diabetes mellitus after a follow-up period of 5 years. After percutaneous coronary intervention patients with diabetes mellitus are under higher risk of death, restenosis and stent thrombosis (ST) compared to non-diabetic patients. In 126 centers worldwide 3067 patients were enrolled in the NOBORI 2 registry, 888 patients suffered from diabetes mellitus (DM), 213 of them (14%) being insulin dependent (IDDM). Five years follow-up has been completed in this study. At 5 years, 89.3% of the patients were available for follow-up. The reported target lesion failure (TLF) rates at 5 years were 12.39% in DM group and 7.34% in non-DM group; (p < 0.0001). In the DM group, the TLF rate in patients with IDDM was significantly higher than in the non-IDDM subgroup (17.84 vs. 10.67%; p < 0.01). The rate of ST at 5 years was not different among diabetic versus non-diabetic patients or IDDM versus NIDDM. Only 10 (<0.4%) very late stent thrombotic events beyond 12 months occurred. The Nobori DES performed well in patients with DM. As expected patients with DM, particularly those with IDDM, had worse outcomes. However, the very low rate of very late stent thrombosis in IDDM patients might have significant clinical value in the treatment of these patients. Clinical trial registration ISRCTN81649913; http://www.controlled-trials.com/isrctn/search.html?srch=81649913&sort=3&dir=desc&max=10.
Ro, Kyung Won; Chang, Woo-Jin; Kim, Ho; Koo, Yoon-Mo; Hahn, Jong Hoon
2003-09-01
Capillary electrochromatography (CEC) and preconcentration of neutral compounds have been realized on poly(dimethylsiloxane) (PDMS) microchips. The channels are coated with polyelectrolyte multilayers to avoid absorption of hydrophobic analytes into PDMS. The structures of a microchip include an injector and a bead chamber with integrated frits, where the particles of the stationary phase are completely retained. Dimensions of the frit structures are 25 micro mx20 micro m, and the space between the structures is 3 micro m. A neutral compound, BODIPY, that is strongly absorbed into native PDMS, is successfully and selectively retained on octadecylsilane-coated silica beads in the bead chamber with a concentration enhancement of up to 100 times and eluted with elution buffer solution containing 70% acetonitrile. Preconcentrations and CEC separations of coumarins have been conducted with the same device and achieved complete separations in less than 50 s.
Rao, R R; Chatt, A
1991-07-01
A simple preconcentration neutron activation analysis (PNAA) method has been developed for the determination of low levels of iodine in biological and nutritional materials. The method involves dissolution of the samples by microwave digestion in the presence of acids in closed Teflon bombs and preconcentration of total iodine, after reduction to iodide with hydrazine sulfate, by coprecipitation with bismuth sulfide. The effects of different factors such as acidity, time for complete precipitation, and concentrations of bismuth, sulfide, and diverse ions on the quantitative recovery of iodide have been studied. The absolute detection limit of the PNAA method is 5 ng of iodine. Precision of measurement, expressed in terms of relative standard deviation, is about 5% at 100 ppb and 10% at 20 ppb levels of iodine. The PNAA method has been applied to several biological reference materials and total diet samples.
Ulusoy, Halil Ibrahim
2014-01-01
A new micelle-mediated extraction method was developed for preconcentration of ultratrace Hg(II) ions prior to spectrophotometric determination. 2-(2'-Thiazolylazo)-p-cresol (TAC) and Ponpe 7.5 were used as the chelating agent and nonionic surfactant, respectively. Hg(II) ions form a hydrophobic complex with TAC in a micelle medium. The main factors affecting cloud point extraction efficiency, such as pH of the medium, concentrations of TAC and Ponpe 7.5, and equilibration temperature and time, were investigated in detail. An overall preconcentration factor of 33.3 was obtained upon preconcentration of a 50 mL sample. The LOD obtained under the optimal conditions was 0.86 microg/L, and the RSD for five replicate measurements of 100 microg/L Hg(II) was 3.12%. The method was successfully applied to the determination of Hg in environmental water samples.
Narin, Ibrahim; Surme, Yavuz; Bercin, Erdogan; Soylak, Mustafa
2007-06-25
In the presented work, alpha-benzoin oxime immobilized SP70 chelating resin was synthesized for separation and preconcentration of Pb(II), Cd(II), Co(II) and Cr(III). The optimization procedure for analytical parameters including pH, eluent type, flow rate, etc. was examined in order to gain quantitative recoveries of analyte ions. The effects of foreign ions on the recoveries of studied metal ions were also investigated. The detection limits (3sigma) were found to be 16.0, 4.2, 1.3, 2.4microgL(-1) for Pb, Cd, Co and Cr, respectively. The preconcentration factor was 75 for Pb, 100 for Cd, Co and Cr. The optimized method was validated with certified reference materials and successfully applied to the waters, crops and pharmaceutical samples with good results (recoveries greater than 95%, R.S.D. lower than 10%).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuathilake, A.I.; Chatt, A.
1980-05-01
An analytical method has been developed for the determination of submicrogram quantities of molybdenum in sea and esturaine water. The method consists of preconcentration of molybdenum with BETA-naphthoin oxime followed by the determination of the element employing neutron activation analysis. Various factors that can influence yield and selectivity of the preconcentration process have been investigated in detail. A comparison study between ..cap alpha..-benzoin oxime and BETA-naphthoin oxime in preconcentrating molybdenum has been carried out using a standard steel sample. The method has been applied to determine molybdenum content of sea and estuarine water. A detection limit of 0.32 ..mu..g Momore » L/sup -1/ seawater has been acheived. The precision and accuracy of the method have been evaluated using an intercomparison fresh water and a biological standard reference material. 1 figure, 9 tables.« less
Cong, Yongzheng; Katipamula, Shanta; Geng, Tao; Prost, Spencer A; Tang, Keqi; Kelly, Ryan T
2016-02-01
A microfluidic platform was developed to perform online electrokinetic sample preconcentration and rapid hydrodynamic sample injection for zone electrophoresis using a single microvalve. The polydimethylsiloxane microchip comprises a separation channel, a side channel for sample introduction, and a control channel which is used as a pneumatic microvalve aligned at the intersection of the two flow channels. The closed microvalve, created by multilayer soft lithography, serves as a nanochannel preconcentrator under an applied electric potential, enabling current to pass through while preventing bulk flow. Once analytes are concentrated, the valve is briefly opened and the stacked sample is pressure injected into the separation channel for electrophoretic separation. Fluorescently labeled peptides were enriched by a factor of ∼450 in 230 s. This method enables both rapid analyte concentration and controlled injection volume for high sensitivity, high-resolution CE. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Wach, Paul
Due to risk of environmental and biological accumulation of Cadmium (Cd), improved methods of early detection and monitoring must be explored as a preventative measure. Listed as one of the top three toxic heavy metals by the Environmental Protection Agency (EPA), the effects on ecological and human systems have well documented side-effects of physical mutation, reproductive sterility, kidney failure, liver disease, bone loss, and death. Found in batteries, metal plating, pigments, plastics, and cigarettes, Cd is also used as a neutron absorber in the nuclear industry as well as having 3 known radioactive isotopes. Urine Cd levels, which have been widely used to predict whole body levels, increase when kidney damage occurs, thus increasing the importance to monitor and detect as early as possible. Although several methods of detection and monitoring are currently in use, they are insufficient for reasons including massive expense, weak specificity causing false readings, and/or a lack of portability. By exploiting naturally occurring mechanisms known to micro-/nanofluidics, a novel approach to Cd detection, measurement, and preconcentration was explored using the finite element computational software COMSOL. An open flow system of a nanochannel was explored through manipulation of the surface charge density. With a dominant negatively charged density on the walls, positive surface charge densities were adjacently placed at the center of the nanochannel causing a constriction of flow and allowing preconcentration of the analytes. When the open flow system was scaled up to a microchannel, the mechanism was found to have little effect on constriction of the flow. A preconcentration effect was discovered in a closed flow system when the adjacent patches were modeled as being impermeable to charge, causing the molecules to migrate to and remain at the central region of the microchannel once the dynamic process reached steady state. It was found to have the ability to concentrate Cd at an initial concentration of 0.5 mol/m3, which is nearly half the limit of commercially available technology. Additionally, this preconcentration mechanism was demonstrated to potentially advance its capabilities by attaching channels in series or parallel to further preconcentrate for improved detection. Finally, measurement of extremely low concentrations of Cd is possible due to differences seen in the concentration distribution profiles once steady-state is reached.
2016-07-01
goal of this project was to develop a rapid dissolution methodology for solid environmental samples and a crude pre- concentration of actinides ...environmental solid samples needed to be removed from the samples prior to actinide separation on the ARSIIe system. As a result of this project, two...procedures were developed, one applicable to the pre-concentration of the actinides only and a second for the pre-concentration of both actinides and
Force fields of charged particles in micro-nanofluidic preconcentration systems
NASA Astrophysics Data System (ADS)
Gong, Lingyan; Ouyang, Wei; Li, Zirui; Han, Jongyoon
2017-12-01
Electrokinetic concentration devices based on the ion concentration polarization (ICP) phenomenon have drawn much attention due to their simple setup, high enrichment factor, and easy integration with many subsequent processes, such as separation, reaction, and extraction etc. Despite significant progress in the experimental research, fundamental understanding and detailed modeling of the preconcentration systems is still lacking. The mechanism of the electrokinetic trapping of charged particles is currently limited to the force balance analysis between the electric force and fluid drag force in an over-simplified one-dimensional (1D) model, which misses many signatures of the actual system. This letter studies the particle trapping phenomena that are not explainable in the 1D model through the calculation of the two-dimensional (2D) force fields. The trapping of charged particles is shown to significantly distort the electric field and fluid flow pattern, which in turn leads to the different trapping behaviors of particles of different sizes. The mechanisms behind the protrusions and instability of the focused band, which are important factors determining overall preconcentration efficiency, are revealed through analyzing the rotating fluxes of particles in the vicinity of the ion-selective membrane. The differences in the enrichment factors of differently sized particles are understood through the interplay between the electric force and convective fluid flow. These results provide insights into the electrokinetic concentration effect, which could facilitate the design and optimization of ICP-based preconcentration systems.
Nomngongo, Philiswa N; Catherine Ngila, J; Kamau, Joseph N; Msagati, Titus A M; Marjanovic, Ljiljana; Moodley, Brenda
2013-07-17
Chelex-100, Dowex 50W-x8 and Dowex MAC-3 exchange resins were investigated for separation and pre-concentration of trace amounts of Cd, Cr, Cu, Fe, Mn, Pb, Ti and Zn in alcohols with respect to retention and desorption characteristics. Dowex 50W-x8 was found to be the best sorbent with percentages recoveries >95%. In addition, Chelex-100 appeared to be suitable for the pre-concentration of Cu, Fe and Zn, whereas Dowex MAC-3 was selective for Cu and Fe. Therefore, Dowex 50W-x8 was used for further investigations. The relative standard deviations <4% (n=20), limits of detection and quantification were 0.1-1.2 μg L(-1) and 0.3-1.5 μg L(-1), respectively. The SPE method was validated against a certified reference material and the results were in agreement with certified values. The accuracy of the optimized method was verified by the recovery test in the spiked alcohol samples. The accuracy and spike recovery test for different metal ions were in the range 98-102% and 95-105%, respectively. The optimized method was applied to the separation and pre-concentration of metal ions in different commercial alcohol samples. Copyright © 2013 Elsevier B.V. All rights reserved.
Karimipour, Gholamreza; Ghaedi, Mehrorang; Sahraei, Reza; Daneshfar, Ali; Biyareh, Mehdi Nejati
2012-01-01
In this study, a new sorbent based on the gold nanoparticle loaded in activated carbon (Au-NP-AC) was synthesized and modified by bis(4-methoxy salicylaldehyde)-1,2-phenylenediamine (BMSAPD). This sorbent, which is abbreviated as Au-NP-AC-BMSAPD, has been applied for the enrichment and preconcentration of trace amounts of Co(2+), Cu(2+), Ni(2+), Fe(2+), Pb(2+), and Zn(2+) ions in real samples. All metal ions under study were retained on the Au-NP-AC-BMSAPD sorbent by complexation of the ions with the BMSAPD ligand, providing an efficient preconcentration fashion. The retained metal ions were then eluted from the sorbent by HNO(3) and detected by flame atomic absorption spectrometry. The analytical parameters including pH, amount of ligand, and the nature of the eluent and solid phase were evaluated to obtain the optimum condition for the preconcentration factor. Following the optimum conditions, a preconcentration factor of 200 was obtained for all the metal ions under study with detection limits of 1.4-2.6 ng mL(-1). The method has been successfully applied for the extraction and determination of the ion content in the same real samples with recoveries in the range of 95-99.6% and a relative standard deviation lower than 4.0%.
Ptolemy, Adam S; Tran, Lara; Britz-McKibbin, Philip
2006-07-15
Capillary electrophoresis (CE) represents a versatile platform for integrating sample pretreatment with chemical analysis because of its ability to tune analyte electromigration and band dispersion properties in discontinuous electrolyte systems. In this article, a single-step method that combines on-line sample preconcentration with in-capillary chemical derivatization is developed for rapid, sensitive, and enantioselective analysis of micromolar levels of amino acids that lack intrinsic chromophores by CE with UV detection. Time-resolved electrophoretic studies revealed two distinct stages of amino acid band narrowing within the original long sample injection plug occurring both prior to and after in-capillary labeling via zone passing by ortho-phthalaldehyde/N-acetyl l-cysteine (OPA/NAC). This technique enabled direct analysis of d-amino acids in a 95% enantiomeric excess mixture with sub-micromolar detection limits and minimal sample handling, where the capillary functions as a preconcentrator, microreactor, and chiral selector. On-line sample preconcentration with chemical derivatization CE (SPCD-CE) was applied to study the enantioselective amino acid flux in Escherichia coli bacteria cultures, which demonstrated a unique l-Ala efflux into the extracellular medium. New strategies for high-throughput analyses of low-abundance metabolites are important for understanding fundamental physiological processes in bacteria required for screening the efficacy of new classes of antibiotics as well as altered metabolism in genetically modified mutant strains.
Baki, Mostafa Hossein; Shemirani, Farzaneh; Khani, Rouhollah
2013-05-01
Application of treated sawdust with NaOH as a green and economical sorbent for simultaneous preconcentration of trace amounts of Cd(II), Co(II), and Pb(II) ions from liver, lettuce, fish, and water as test samples with complicated matrices was investigated. Various parameters, such as effect of pH and contact time, breakthrough volume, type, and concentration of eluent and interference of ions were studied. The sorption was quantitative in the pH of 5.0 to 7.0 and desorption occurred instantaneously with 5.0 mL of mixed solutions of ethanol and 2.0 mol/L HNO3 -HCl and the amount of ions was measured by using flame atomic absorption spectrometry. Linearity was maintained at 3 to 500 μg/L for cobalt, 5.0 to 800 μg/L for lead, and 2.0 to 300 μg/L for cadmium in the original solution. The relative standard deviation was less than 1.80% (n = 6, with concentration of 0.3 mg/L for cadmium and 0.5 mg/L for lead and cobalt). Detection limits and maximum capacity of the sorbent for Co (II), Cd (II), and Pb (II) in the original solution were 0.86, 0.50, and 1.7 μg/L and 28.5, 30.6, and 47.3 mg/g, respectively. The results for spiked real samples, effect of interfering ions, and adsorption capacity indicated that the applicability of this method for lead preconcentration is better than cadmium and cobalt preconcentration from complicated matrices. Practical Application: Sawdust can be applied as a green and economical sorbent for simultaneous preconcentration and solid-phase extraction of metal ions from food and environmental samples with complicated matrices. © 2013 Institute of Food Technologists®
Barua, Suman; Rahman, Ismail M M; Alam, Iftakharul; Miyaguchi, Maho; Sawai, Hikaru; Maki, Teruya; Hasegawa, Hiroshi
2017-08-15
A relatively rapid and precise method is presented for the determination of lead in aqueous matrix. The method consists of analyte quantitation using the liquid electrode plasma-optical emission spectrometry (LEP-OES) coupled with selective separation/preconcentration by solid-phase extraction (SPE). The impact of operating variables on the retention of lead in SPEs such as pH, flow rate of the sample solution; type, volume, flow rate of the eluent; and matrix effects were investigated. Selective SPE-separation/preconcentration minimized the interfering effect due to manganese in solution and limitations in lead-detection in low-concentration samples by LEP-OES. The LEP-OES operating parameters such as the electrical conductivity of sample solution; applied voltage; on-time, off-time, pulse count for applied voltage; number of measurements; and matrix effects have also been optimized to obtain a distinct peak for the lead at λ max =405.8nm. The limit of detection (3σ) and the limit of quantification (10σ) for lead determination using the technique were found as 1.9 and 6.5ng mL -1 , respectively. The precision, as relative standard deviation, was lower than 5% at 0.1μg mL -1 Pb, and the preconcentration factor was found to be 187. The proposed method was applied to the analysis of lead contents in the natural aqueous matrix (recovery rate:>95%). The method accuracy was verified using certified reference material of wastewaters: SPS-WW1 and ERM-CA713. The results from LEP-OES were in good agreement with inductively coupled plasma optical emission spectrometry measurements of the same samples. The application of the method is rapid (≤5min, without preconcentration) with a reliable detection limit at trace levels. Copyright © 2017 Elsevier B.V. All rights reserved.
1992-06-01
que ce que l’on peut esp~rer avec des hommes. Le second serait un robot de renseignement, sorte d’unit6 4 recherche dans la profondeur , mis en place par...3 1ime Seminaire sur la robotique du champ de Bataille Groupe sur la Recherche pour la Defense S92-25111 92 9 14 00O ;-" SANS CLASSIFICATION...6l6mentaires de pilotage d’un v~hicule en vue d’en am~liorer et d’en simplifier la t~l6commandabilit6 by M. Urvoy - Adaptation de l’algorithme A * 6 la
2010-01-01
protein, AlexaFluor647– chicken IgG (Alexa647–chick IgG). Antibody-labeled MNPs (Alexa647– chick–MNPs) were used to preconcentrate the target via magnetic...separation and as the tracer to dem- onstrate binding to slides modified with anti- chicken IgG as a capture agent. A full optimization study of the...magnetically assisted transport evanescent field fluoroimmunoassay; Alexa647–chick–MNPs, MNPs functionalized with fluorescently labeled target chicken IgG
NASA Astrophysics Data System (ADS)
Postnov, V. N.; Rodinkov, O. V.; Moskvin, L. N.; Novikov, A. G.; Bugaichenko, A. S.; Krokhina, O. A.
2016-02-01
Information on carbon nanostructures (fullerenes, nanotubes, graphene, nanodiamond and nanodispersed active carbon) used to develop high-performance sorbents of organics and heavy metal ions from aqueous solutions is collected and analyzed. The advantages in the synthesis of hybrid carbon nanostructures and the possibilities of surface modification of these systems in order to carry out fast sorption pre-concentration are considered. Prospects for application of these materials in sorption technologies and analytical chemistry are discussed. The bibliography includes 364 references.
NASA Astrophysics Data System (ADS)
Bubnova, Tatyana; Skamnitskaya, Lubov; Gorbunova, Elena; Chertov, Alexandr
2017-12-01
The use of muscovite is determined by its industrial look and quality. Sheet mica is traditionally used as electrically insulating material. Crushed mica dry or wet grinding and scrap (waste from the production of sheet mica) are used as electrical insulating material (for example, mica paper), filler in the manufacture of various kinds of fillers, grout and paint etc. In addition, today there is a steady demand for micronized muscovite for the production of decorative coatings and cosmetics. On the territory of the Republic of Karelia (Russian Federation) there is a significant number of deposits and occurrences moscoviticarum rocks. Promising target small iron-poor Muscovite is the manifestation of the Eastern Hitware identified in 1999. The average mineral composition of rocks of the productive series: quartz - 10-71%; Muscovite - 8-42%; plagioclase - 1,5-28%; kyanite - 2-13,5%; biotite, and 0.1-8%; ore (pyrite, sphalerite) and 1.5 - 11%. Enrichment of this type of mineral raw materials may be carried out using traditional methods - gravity, magnetic separation, flotation. Textural-structural and mineralogical features, a high degree of secondary changes (thin intergrowths of muscovite with graphite, ferritization, the decrease of the strength characteristics) and the availability of areas and dedicated silicification abundant pyrite mineralization and its vein type significantly impoverish muscovite ore, necessitate the adjustment of technological schemes and modes of enrichment. Possibilities of improvement of processes of pretreatment and subsequent enrichment is possible using the methods of pre-sorting that represent rational and cost-effective alternative to traditional beneficiation processes. To explore the possibility of using the optical methods being preconcentration, experimental study of the contrast of properties of samples of the original ore. The study was carried out on crushed material, graded by size: -10+5; -20+10; -40+20 -60 and+40 mm. the results revealed the main search area colour shades in images of mineral samples in the colour system HLS - grey, brown, bright yellow-orange and purple. The correlation between the colour characteristics of the individual pieces and the content of muscovite. To implement the sort method of photometric separation, the threshold separation can be determined by one of the highlighted areas of the gamut or in their entirety. Next, the sorted ore with the same mineralogical and structural properties can effectively be enriched with gravitational methods. In the complex process of enrichment, it is possible to obtain, in addition to muscovite, quartz and kyanite products, which undoubtedly will increase the output of marketable products.
Manginell, Ronald P.; Frye-Mason, Gregory C.
2001-01-01
A chemical preconcentrator is disclosed with applications to chemical sensing and analysis. The preconcentrator can be formed by depositing a resistive heating element (e.g. platinum) over a membrane (e.g. silicon nitride) suspended above a substrate. A coating of a sorptive material (e.g. a microporous hydrophobic sol-gel coating or a polymer coating) is formed on the suspended membrane proximate to the heating element to selective sorb one or more chemical species of interest over a time period, thereby concentrating the chemical species in the sorptive material. Upon heating the sorptive material with the resistive heating element, the sorbed chemical species are released for detection and analysis in a relatively high concentration and over a relatively short time period. The sorptive material can be made to selectively sorb particular chemical species of interest while not substantially sorbing other chemical species not of interest. The present invention has applications for use in forming high-sensitivity, rapid-response miniaturized chemical analysis systems (e.g. a "chem lab on a chip").
See, Wong Pooi; Heng, Lee Yook; Nathan, Sheila
2015-01-01
A new approach for the development of a highly sensitive aluminium(III) ion sensor via the preconcentration of aluminium(III) ion with a self-assembled monolayer on a gold nanoparticles modified screen-printed carbon electrode and current mediation by potassium ferricyanide redox behavior during aluminium(III) ion binding has been attempted. A monolayer of mercaptosuccinic acid served as an effective complexation ligand for the preconcentration of trace aluminium; this led to an enhancement of aluminium(III) ion capture and thus improved the sensitivity of the sensor with a detection limit of down to the ppb level. Under the optimum experimental conditions, the sensor exhibited a wide linear dynamic range from 0.041 to 12.4 μM. The lower detection limit of the developed sensor was 0.037 μM (8.90 ppb) using a 10 min preconcentration time. The sensor showed excellent selectivity towards aluminium(III) ion over other interference ions.
Xu, Hongbo; Wu, Yun; Wang, Jian; Shang, Xuewei; Jiang, Xiaojun
2013-12-01
A new method that utilizes pretreated silica gel as an adsorbent has been developed for simultaneous preconcentration of trace Cd(II) and Pb(II) prior to the measurement by flame atomic absorption spectrometry. The effects of pH, the shaking time, the elution condition and the coexisting ions on the separation/preconcentration conditions of analytes were investigated. Under optimized conditions, the static adsorption capacity of Cd(II) and Pb(II) were 45.5 and 27.1mg/g, the relative standard deviations were 3.2% and 1.7% (for n = 11), and the limits of detection obtained were 4.25 and 0.60 ng/mL, respectively. The method was validated by analyzing the certified reference materials GBW 07304a (stream sediment) and successfully applied to the analysis of various treated wastewater samples with satisfactory results. Copyright © 2013 The Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences. Published by Elsevier B.V. All rights reserved.
Permeation absorption sampler with multiple detection
Zaromb, Solomon
1990-01-01
A system for detecting analytes in air or aqueous systems includes a permeation absorption preconcentrator sampler for the analytes and analyte detectors. The preconcentrator has an inner fluid-permeable container into which a charge of analyte-sorbing liquid is intermittently injected, and a fluid-impermeable outer container. The sample is passed through the outer container and around the inner container for trapping and preconcentrating the analyte in the sorbing liquid. The analyte can be detected photometrically by injecting with the sorbing material a reagent which reacts with the analyte to produce a characteristic color or fluorescence which is detected by illuminating the contents of the inner container with a light source and measuring the absorbed or emitted light, or by producing a characteristic chemiluminescence which can be detected by a suitable light sensor. The analyte can also be detected amperometrically. Multiple inner containers may be provided into which a plurality of sorbing liquids are respectively introduced for simultaneously detecting different analytes. Baffles may be provided in the outer container. A calibration technique is disclosed.
Applications of organo-silica nanocomposites for SPNE of Hg(II)
NASA Astrophysics Data System (ADS)
Kaur, Anupreet
2016-02-01
An analytical method using modified SiO2 nanoparticles as solid-phase extractant has been developed for the preconcentration of trace amounts of Hg(II) in different water samples. Conditions of the analysis such as preconcentration factor, effect of pH, sample volume, shaking time, elution conditions and effects of interfering ions for the recovery of analyte were investigated. The adsorption capacity of nanometer SiO2-APTMS was found to be 181.42 µmol g-1 at optimum pH and the detection limit (3σ) was 0.45 µg L-1. The extractant showed rapid kinetic sorption. The adsorption equilibrium of Hg(II) on nanometer SiO2-APTMS was achieved just in 15 min. Adsorbed Hg(II) was easily eluted with 4 mL of 2.0 M hydrochloric acid. The maximum preconcentration factor was 75. The method was applied for the determination of trace amounts of Hg(II) in various synthetic samples and water samples.
Ghaedi, Mehrorang; Montazerozohori, Mortaza; Tabatabie, Maryam; Noormohamadi, Hamid; Haghighi, Alireza Borhan
2012-01-01
The efficiency of modified activated carbon (AC) and multiwalled carbon nanotubes (MWCNTs) for the separation/preconcentration and determination of Co, Cd, Pb, Zn, and Cu following their complexation by bis(3-nitrobenzylidene)-1,2-ethanediamine has been described and compared. A one-at-a-time optimization method investigated the influence of various parameters that significantly influence the recoveries of the studied metal ions. At the optimum values of all variables, the response was linear over the range of 0.01-0.3 microg/mL, and detection limit (3 SDb/m, n = 10) was between 1.41-2.05 ng/mL for both sorbents while the preconcentration factor was 100 for AC and 500 for MWCNTs. The method was successfully applied for preconcentration and determination of trace amount of the aforementioned ions in various real samples such as orange, lettuce, bread, and pear.
2014-01-01
The survival rate of lung cancer can be significantly improved by monitoring biomarkers in exhaled air that indicate diseases in early stage, so it is very important to develop micro analytical systems which can offer a fast, on-site, real-time detecting biomarkers in exhaled air. In this paper, a mini-gas chromatography (GC)-photo-ionization detector (PID) system integrated with a micro GC column and a micro pre-concentrator was developed for forming an inexpensive, fast, and non-invasive diagnostic tool for lung cancer. This system has very strong concentrate ability owing to its integrated micro pre-concentrator, which make the detection of trace components in exhaled air very easy. In addition, the integrated micro GC column can separate complex mixtures, which overcome low resolution and poor anti-interference ability of other instruments. The results indicated that the mini-GC-PID system can effectively separate and detect the biomarkers at parts-per-billion (ppb) level. PMID:25339856
The mercury isotope composition of Arctic coastal seawater
NASA Astrophysics Data System (ADS)
Štrok, Marko; Baya, Pascale Anabelle; Hintelmann, Holger
2015-11-01
For the first time, Hg isotope composition of seawater in the Canadian Arctic Archipelago is reported. Hg was pre-concentrated from large volumes of seawater sampling using anion exchange resins onboard the research vessel immediately after collection. Elution of Hg was performed in laboratory followed by isotope composition determination by multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). For comparison, seawater from two stations was shipped to the laboratory and processed within it. Results showed negative mass-dependent fractionation in the range from -2.85 to -1.10‰ for δ202Hg, as well as slightly positive mass-independent fractionation of odd Hg isotopes. Positive mass-independent fractionation of 200Hg was also observed. Samples that were pre-concentrated in the laboratory showed different Hg isotope signatures and this is most probably due to the abiotic reduction of Hg in the dark by organic matter during storage and shipment after sampling. This emphasizes the need for immediate onboard pre-concentration.
Sayar, Omid; Zhad, Hamid Reza Lotfi Zadeh; Sadeghi, Omid; Amani, Vahid; Najafi, Ezzatolla; Tavassoli, Najmeh
2012-12-01
We have developed a facile and highly sensitive sorbent for cadmium and lead ions. It is based on Fe₃O₄ nanoparticles functionalized with a derivative of picoline and was characterized by scanning electron microscopy, differential thermographic analysis, and elemental analysis. The material can be applied to the preconcentration of lead and cadmium ions. Factors such as the type, concentration and volume of eluent, the pH of the sample solution, the time for extraction, and the volume of the sample were studied. The effects of a variety of ions on preconcentration and recovery of these ions were also investigated. The ions were determined by FAAS, and the limits of detection are <0.8 and <0.061 μg L⁻¹ for lead and cadmium, respectively. Recoveries and precisions are >98.0 % and <1.3 %, respectively. The method was validated by analyzing several certified leaf reference materials.
Ghasemi, Jahan B; Zolfonoun, E
2010-01-15
A new solid phase extraction method for separation and preconcentration of trace amounts of uranium, thorium, and zirconium in water samples is proposed. The procedure is based on the adsorption of U(VI), Th(IV) and Zr(IV) ions on a column of Amberlite XAD-2000 resin loaded with alpha-benzoin oxime prior to their simultaneous spectrophotometric determination with Arsenazo III using orthogonal signal correction partial least squares method. The enrichment factor for preconcentration of uranium, thorium, and zirconium was found to be 100. The detection limits for U(VI), Th(IV) and Zr(IV) were 0.50, 0.54, and 0.48microgL(-1), respectively. The precision of the method, evaluated as the relative standard deviation obtained by analyzing a series of 10 replicates, was below 4% for all elements. The practical applicability of the developed sorbent was examined using synthetic seawater, natural waters and ceramic samples.
Sereshti, Hassan; Samadi, Soheila; Jalali-Heravi, Mehdi
2013-03-08
Ultrasound assisted extraction (UAE) followed by dispersive liquid-liquid microextraction (DLLME) was used for extraction and preconcentration of volatile constituents of six tea plants. The preconcentrated compounds were analyzed by gas chromatography-mass spectrometry (GC-MS). Totally, 42 compounds were identified and caffeine was quantitatively determined. The main parameters (factors) of the extraction process were optimized by using a central composite design (CCD). Methanol and chloroform were selected as the extraction solvent and preconcentration solvent, respectively .The optimal conditions were obtained as 21 in for sonication time; 32°C for temperature; 27 L for volume of extraction solvent and 7.4% for salt concentration (NaCl/H(2)O). The determination coefficient (R(2)) was 0.9988. The relative standard deviation (RSD %) was 4.8 (n=5), and the enhancement factors (EFs) were 4.0-42.6. Copyright © 2013 Elsevier B.V. All rights reserved.
Islam, Aminul; Zaidi, Noushi; Ahmad, Hilal; Kumar, Suneel
2015-05-01
In this study, mesoporous glycidyl methacrylate-divinylbenzene-based chelating resin was synthesized and grafted with diethylenetriamine through epoxy ring-opening reaction. The synthesized resin was characterized by elemental analysis, infrared spectroscopy, surface area and pore size analysis, scanning electron microscopy, energy-dispersive spectroscopy, and thermogravimetry. The resin was used for the first time as an effective sorbent for the preconcentration of nickel in electroplating wastewater samples. The analytical variables like pH, flow rate for sorption/desorption, and eluate selection were systematically investigated and optimized. The uniform and monolayer sorption behavior of resin for nickel was proved by an evident fit of the equilibrium data to a Langmuir isotherm model. Under optimized conditions, the resin was observed to show a good sorption capacity of 20.25 mg g(-1) and >96% recovery of nickel even in the presence of a large number of competitive matrix ions. Its ability to extract trace amount of nickel was exhibited by low preconcentration limit (5.9 μg L(-1)). The calibration curve was found to be linear (R(2) = 0.998) in the concentration range of 6.0-400.0 μg L(-1). Coefficient of variation of less than 5 for all the analysis indicated good reproducibility. The reliability was evaluated by the analysis of standard reference material (SRM) and recovery experiments. The applicability of the resin for the systematic preconcentration of nickel is substantiated by the analysis of electroplating wastewater and river water samples. Graphical abstract ᅟ.
Boublík, Milan; Riesová, Martina; Dubský, Pavel; Gaš, Bohuslav
2018-06-01
Conductivity detection is a universal detection technique often encountered in electrophoretic separation systems, especially in modern chip-electrophoresis based devices. On the other hand, it is sparsely combined with another contemporary trend of enhancing limits of detection by means of various preconcentration strategies. This can be attributed to the fact that a preconcentration experimental setup usually brings about disturbances in a conductivity baseline. Sweeping with a neutral sweeping agent seems a good candidate for overcoming this problem. A neutral sweeping agent does not hinder the conductivity detection while a charged analyte may preconcentrate on its boundary due to a decrease in its effective mobility. This study investigates such sweeping systems theoretically, by means of computer simulations, and experimentally. A formula is provided for the reliable estimation of the preconcentration factor. Additionally, it is demonstrated that the conductivity signal can significantly benefit from slowing down the analyte and thus the overall signal enhancement can easily overweight amplification caused solely by the sweeping process. The overall enhancement factor can be deduced a priori from the linearized theory of electrophoresis implemented in the PeakMaster freeware. Sweeping by neutral cyclodextrin is demonstrated on an amplification of a conductivity signal of flurbiprofen in a real drug sample. Finally, a possible formation of unexpected system peaks in systems with a neutral sweeping agent is revealed by the computer simulation and confirmed experimentally. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Arantes de Carvalho, Gabriel G; Kondaveeti, Stalin; Petri, Denise F S; Fioroto, Alexandre M; Albuquerque, Luiza G R; Oliveira, Pedro V
2016-12-01
Analytical methods for the determination of rare earth elements (REE) in natural waters by plasma spectrochemical techniques often require sample preparation procedures for analytes preconcentration as well as for removing matrix constituents, that may interfere on the analytical measurements. In the present work, calcium alginate (CA) beads were used for the first time aiming at Ce, La and Nd preconcentration from groundwater samples for further determination by inductively coupled plasma optical emission spectrometry (ICP OES). Test samples were analyzed in batch mode by transferring a 40mL test portion (pH=5±0.2) into a 50mL polyethylene flask containing 125mg CA beads. After 15min contact, the analytes were quantitatively extracted from the loaded CA beads with 2.0mL of 1.0molL -1 HCl solution for further determination by ICP OES, using Ce (II) 456.236, La (II) 379.478 and Nd (II) 430.358nm emission lines. The proposed approach is a reliable alternative for REE single-stage preconcentration from aqueous samples, as it provided accurate results based on the addition and recovery analysis of groundwater. The results obtained by the proposed method were also compared with those from reference method based on inductively coupled plasma mass spectrometry (ICP-MS) and no significant differences were observed after applying the Student's t-test at 95% confidence level. Copyright © 2016 Elsevier B.V. All rights reserved.
Golshekan, Mostafa; Shariati, Shahab
2013-01-01
In this study, magnetite nanoparticles with particle size lower than 47 nm were synthesized and were applied for preconcentration of Pb2+ ions from aqueous solutions. To preconcentrate the Pb2+ ions, the surface of the synthesized nano particles was modified with sodium dodecyl sulfate (SDS) as an anionic surfactant. A new chelating agent (2-((E)-2-amino-4,5-dinitrophenylimino)methyl)phenol) was synthesized and used to form a very stable complex with Pb2+ ions. The lead ions formed complexes and were quantitatively extracted with SDS-coated magnetite nanoparticles. After magnetic separation of adsorbent, the adsorbent was eluted with 0.5% (v/v) HC1 in dimethyl sulfoxide (DMSO) prior to analysis by flame atomic absorption spectrometry (FAAS). Orthogonal array design (OAD) was used to study and optimize the different experimental parameters. Under the optimum conditions, enhancement factor up to 63.5 was achieved for extraction from only 10 mL of sample solution and the relative standard deviation (RSD %) of the method was lower than 2.8%. The obtained calibration curve was linear in the range of 1-300 pg L-' with reasonable linearity (r2 > 0.998). The limit of detection (LOD) based on S/N = 3 was 0.04 microg L(-1) for 10 mL sample volumes. Finally, applicability of the proposed method was successfully confirmed by preconcentration and determination of trace amounts of lead ions in environmental samples and satisfactory results were obtained.
Escudero, Luis A; Cerutti, S; Olsina, R A; Salonia, J A; Gasquez, J A
2010-11-15
An on-line preconcentration procedure using solid phase extraction (SPE) for the determination of copper in different water samples by inductively coupled plasma optical emission spectrometry (ICP-OES) is proposed. The copper was retained on a minicolumn filled with ethyl vinyl acetate (EVA) at pH 8.0 without using any complexing reagent. The experimental optimization step was performed using a two-level full factorial design. The results showed that pH, sample loading flow rate, and their interaction (at the tested levels) were statistically significant. In order to determine the best conditions for preconcentration and determination of copper, a final optimization of the significant factors was carried out using a central composite design (CCD). The calibration graph was linear with a regression coefficient of 0.995 at levels near the detection limit up to at least 300 μg L(-1). An enrichment factor (EF) of 54 with a preconcentration time of 187.5 s was obtained. The limit of detection (3σ) was 0.26 μg L(-1). The sampling frequency for the developed methodology was about 15 samples/h. The relative standard deviation (RSD) for six replicates containing 50 μg L(-1) of copper was 3.76%. The methodology was successfully applied to the determination of Cu in tap, mineral, river water samples, and in a certified VKI standard reference material. Copyright © 2010 Elsevier B.V. All rights reserved.
Ptolemy, Adam S; Britz-McKibbin, Philip
2006-02-17
New strategies for integrating sample pretreatment with chemical analyses under a single format is required for rapid, sensitive and enantioselective analyses of low abundance metabolites in complex biological samples. Capillary electrophoresis (CE) offers a unique environment for controlling analyte/reagent band dispersion and electromigration properties using discontinuous electrolyte systems. Recent work in our laboratory towards developing a high-throughput CE platform for low abundance metabolites via on-line sample preconcentration with chemical derivatization (SPCD) is primarily examined in this review, as there have been surprisingly only a few strategies reported in the literature to date. In-capillary sample preconcentration serves to enhance concentration sensitivity via electrokinetic focusing of long sample injection volumes for lower detection limits, whereas chemical derivatization by zone passing is used to expand detectability and selectivity, notably for enantiomeric resolution of metabolites lacking intrinsic chromophores using nanolitre volumes of reagent. Together, on-line SPCD-CE can provide over a 100-fold improvement in concentration sensitivity, shorter total analysis times, reduced sample handling and improved reliability for a variety of amino acid and amino sugar metabolites, which is also amenable to automated high-throughput screening. This review will highlight basic method development and optimization parameters relevant to SPCD-CE, including applications to bacterial metabolite flux and biomarker analyses. Insight into the mechanism of analyte focusing and labeling by SPCD-CE is also discussed, as well as future directions for continued research.
Eco-hydrology: Groundwater flow and site factors in plant ecology
NASA Astrophysics Data System (ADS)
Klijn, Frans; Witte, Jan-Philip M.
Résumé En écologie végétale, le site est un concept central. Un site, c'est l'endroit où une espèce végétale ou une communauté de plantes se développe le site assure un ensemble de conditions dans lesquelles elles vivent. Dans un matériau homogène à l'origine, l'écoulement gravitaire d'une nappe influence les conditions du site par l'intermédiaire de la distribution spatiale des nutriments et d'autres composés chimiques associés. Les remontées d'eau peuvent tout spécialement produire et maintenir les conditions du site essentielles pour différentes espèces et communautés de plantes relativement rares. Les écologues ont porté une attention accrue à ces remontées d'eau, en sorte qu'une coopération avec les hydrologues en a résulté, avec l'émergence d'une discipline propre, l'éco-hydrologie, à la limite des deux domaines scientifiques et liée au concept de site. Aux Pays-Bas, une classification des types d'eau, basée sur l'histoire de l'eau souterraine à proximité de la surface, a été mise en oeuvre pour constituer une base nationale de données géographiques sur les remontées d'eau d'intérêt écologique. Des analyses des correspondances des données de cette base, portant sur l'existence de certaines espèces de plantes, montrent que dans les sols sableux pauvres du Pléistocène la remontée d'eau explique très bien la présence de certaines espèces et communautés, alors que, dans les plaines fluviales et les régions de polders à sols argileux riches, l'influence de la remontée d'eau est masquée par l'importance des caractéristiques des sols. En conclusion donc, certaines espèces de plantes peuvent être utilisées comme des indicateurs de la remontée d'eau dans des diagnostiques et des levés de terrain rapides, mais à condition de prendre en permanence des précautions sur les limites de l'approche. Resumen En ecología botánica un concepto de gran importancia es el de emplazamiento, definido como el lugar que proporciona unas condiciones de vida adecuadas que permiten el crecimiento de una especie o una comunidad botánica. En un material inicialmente homogéneo, el flujo subterráneo gravífico influencia las condiciones del emplazamiento variando la distribución espacial de los nutrientes y de otros agentes químicos relevantes. En especial, el flujo ascendente puede producir y mantener una serie de condiciones que son esenciales para algunas especies y comunidades de plantas relativamente raras. La especial atención hacia este fenómeno ha dado lugar a una cooperación entre ecologistas e hidrogeólogos y a la aparición de una nueva disciplina - eco-hidrología -, en la frontera de los dos campos científicos. En Holanda, se ha usado una clasificación sencilla de tipos de agua para crear una base de datos, a nivel nacional, de lugares donde la presencia de flujos ascendentes pueda ser de interés ecológico. El análisis de correspondencias entre esta base de datos y los tipos de plantas existentes muestra que en los suelos arenosos pobres del Pleistoceno los flujos ascendentes explican la presencia de algunas especies y comunidades de plantas. Por el contrario, en las llanuras fluviales y pólders, con suelos más arcillosos, la influencia de estos flujos es despreciable frente a la relativa a las propias características de los suelos. Se concluye que las especies botánicas se pueden usar como indicadores de la presencia de flujo ascendente sólo en campañas preliminares, pero que el método presenta grandes limitaciones para su extensión a casos generales.
NASA Astrophysics Data System (ADS)
Udalova, A. Yu.; Dmitrienko, S. G.; Apyari, V. V.
2015-06-01
The sorption of tetracycline, oxytetracycline, chlortetracycline, and doxycycline on hyper-cross-linked polystyrene from aqueous and aqueous-organic solutions is studied under static and dynamic conditions in order to extend the range of the sorbents suitable for sorption isolation and the preconcentration of tetracycline antibiotics. Features of tetracycline sorption depending on the acidity of a solution and the nature and concentration of the compounds are explained. It is shown that hyper-crosslinked polystyrene can be used for the group sorption preconcentration of these compounds.
Hemmati, Maryam; Rajabi, Maryam; Asghari, Alireza
2017-11-17
In this research work, two consecutive dispersive solid/liquid phase microextractions based on efficient extraction media were developed for the influential and clean pre-concentration of clonazepam and lorazepam from complicated bio-samples. The magnetism nature of the proposed nanoadsorbent proceeded the clean-up step conveniently and swiftly (∼5min), pursued by a further enrichment via a highly effective and rapid emulsification microextraction process (∼4min) based on a deep eutectic solvent (DES). Finally, the instrumental analysis step was practicable via high performance liquid chromatography-ultraviolet detection. The solid phase used was an adequate magnetic nanocomposite termed as polythiophene-sodium dodecyl benzene sulfonate/iron oxide (PTh-DBSNa/Fe 3 O 4 ), easily and cost-effectively prepared by the impressive co-precipitation method followed by the efficient in situ sonochemical oxidative polymerization approach. The identification techniques viz. FESEM, XRD, and EDX certified the supreme physico-chemical properties of this effective nanosorbent. Also the powerful liquid extraction agent, DES, based on bio-degradable choline chloride, possessed a high efficiency, tolerable safety, low cost, and facile and mild synthesis route. The parameters involved in this versatile hyphenated procedure, efficiently evaluated via the central composite design (CCD), showed that the best extraction conditions consisted of an initial pH value of 7.2, 17mg of the PTh-DBSNa/Fe 3 O 4 nanocomposite, 20 air-agitation cycles (first step), 245μL of methanol, 250μL of DES, 440μL of THF, and 8 air-agitation cycles (second step). Under the optimal conditions, the understudied drugs could be accurately determined in the wide linear dynamic ranges (LDRs) of 4.0-3000ngmL -1 and 2.0-2000ngmL -1 for clonazepam and lorazepam, respectively, with low limits of detection (LODs) ranged from 0.7 to 1.0ngmL -1 . The enrichment factor (EF) and percentage extraction recovery (%ER) values were found to be 75 and 57% for clonazepam and 56 and 42% for lorazepam at the spiked level of 75.0ngmL -1 , possessing proper repeatabilities (relative standard deviation values (RSDs) below 5.9%, n=3). These valid analytical features provided quite accurate drug analyses at therapeutically low spans and levels below potentially toxic domains, implying a proper purification/enrichment of the proposed microextraction procedure. Copyright © 2017 Elsevier B.V. All rights reserved.
Camille Flammarion's observatory: towards a revival
NASA Astrophysics Data System (ADS)
Morel, P.; Pecker, J. C.; Flammarion, A.; Fuentes, P.; Stépanoff, C. A.; Sol, R.; Dufour, G.; Chaufour, R.; Goury-Laffont, J.
2011-06-01
Camille Flammarion's observatory, located in Juvisy-sur-Orge in the suburbs of Paris, has been idle since 1962. Property of the Société Astronomique de France (SAF), it was made available to the city of Juvisy-sur-Orge since 1971, and contains a unique collection of objects and books currently being sorted out. The observatory is being restored by the SAF, thanks to the support of the city of Juvisy-sur-Orge, the French Académie des Sciences and the ``Amis de Camille Flammarion'' association. In 2006, the Maxime Goury Laffont foundation funded the refurbishment of the 240 mm refractor and in 2007 funds were obtained to restore the dome and central building. The main aim of the project is to make this historical place a popular observatory dedicated to astronomy and the sciences which Camille Flammarion enjoyed and contributed to. It constitutes a unique example in France of synergies linking associations, municipality, regional- and national-level institutions.
Šatínský, Dalibor; Naibrtová, Linda; Fernández-Ramos, Carolina; Solich, Petr
2015-09-01
A new on-line SPE-HPLC method using fused-core columns for on-line solid phase extraction and large volume sample injection for increasing the sensitivity of detection was developed for the determination of insecticides fenoxycarb and cis-, trans-permethrin in surface waters. The separation was carried out on fused-core column Phenyl-Hexyl (100×4.6 mm), particle size 2.7 µm with mobile phase acetonitrile:water in gradient mode at flow rate 1.0 mL min(-1), column temperature 45°C. Large volume sample injection (1500 µL) to the extraction dimension using short precolumn Ascentis Express RP C-18 (5×4.6 mm); fused-core particle size 2.7 µm allowed effective sample preconcentration and efficient ballast sample matrix removal. The washing mobile phase consisting of a mixture of acetonitrile:water; 30:70, (v/v) was pumped at flow rate of 0.5 mL min(-1) through the extraction precolumn to the waste. Time of the valve switch for transferring the preconcentrated sample zone from the extraction to the separation column was set at 3rd min. Elution of preconcentrated insecticides from the extraction precolumn and separation on the analytical column was performed in gradient mode. Linear gradient elution started from 40% of acetonitrile at time of valve switch from SPE column (3rd min) to 95% of acetonitrile at 7th min. Synthetic dye sudan I was chosen as an internal standard. UV detection at wavelength 225 nm was used and the method reached the limits of detection (LOD) at ng mL(-1) levels for both insecticides. The method showing on-line sample pretreatment and preconcentration with highly sensitive determination of insecticides was applied for monitoring of fenoxycarb and both permethrin isomers in different surface water samples in Czech Republic. The time of whole analysis including on-line extraction, interferences removal, chromatography separation and system equilibration was less than 8 min. Copyright © 2015 Elsevier B.V. All rights reserved.
Hernández-Borges, Javier; García-Montelongo, Francisco J; Cifuentes, Alejandro; Rodríguez-Delgado, Miguel Angel
2005-04-08
In this work, the combined use of solid-phase extraction (SPE) and on-line preconcentration strategies as normal stacking mode (NSM) and stacking with matrix removal (SWMR) for the ultrasensitive and simultaneous capillary electrophoresis-ultraviolet analysis (CE-UV) of five triazolopyrimidine sulfonanilide pesticides (i.e., diclosulam, cloransulam-methyl, flumetsulam, metosulam and florasulam) in different types of water is investigated. An adequate separation electrolyte for the separation and stacking of these pesticides was obtained, considering also its compatibility with MS detection, which consisted of 24 mM formic acid and 16 mM ammonium carbonate at pH 6.4. It was observed that the use of this running buffer together with the SWMR preconcentration method provided the best results in terms of sensitivity (between 6.54 and 11.9 microg/L) and peak efficiency (up to 550000 theoretical plates per meter, NTP/m). When this on-line preconcentration procedure was combined with an off-line sample preconcentration step as SPE using C18 cartridges, the selected herbicides could be detected in the ng/L range. The optimized SPE-SWMR-CE-UV method was applied to the determination of the selected group of pesticides in spiked and non-spiked mineral and stagnant waters. Recoveries ranged between 55 and 110% and limits of detection between 131 and 342 ng/L. This work shows the great possibilities of the combined use of SPE-SWMR-CE-UV to overcome the sensitivity problems usually linked to CE analysis.
Katsumata, Hideyuki; Kaneco, Satoshi; Suzuki, Tohru; Ohta, Kiyohisa
2006-09-08
A sensitive and selective column adsorption method is proposed for the preconcentration and determination of atrazine and simazine. Atrazine and simazine were preconcentrated on heat-treated diatomaceous earth as an adsorbent and then determined by high-performance liquid chromatography (HPLC). Several parameters on the recoveries of the analytes were investigated. The experimental results showed that it was possible to obtain quantitative analysis when the solution pH was 2 using 100 mL of validation solution containing 1.5 microg of triazines and 5 mL of ethanol as an eluent. Recoveries of atrazine and simazine were 95.7+/-4.2% and 75.0+/-1.9% with a relative standard deviation for seven determinations of 4.7% and 2.7% under optimum conditions. The maximum preconcentration factor was 100 for triazines when 500 mL of sample solution volume was used. The linear ranges of calibration curves for atrazine and simazine were 1-150 ng mL(-1) and 1-300 ng mL(-1), respectively, with correlation coefficients of 0.999 and the detection limits (3Signal-to-Noise) were 0.24 ng mL(-1) and 0.21 ng mL(-1) for atrazine and simazine. The capacity of the adsorbent was also examined and found to be 0.8 mg g(-1) and 1.3 mg g(-1) for atrazine and simazine, respectively. The proposed method was successfully applied to the determination of triazines in river water and tap water samples with high precision and accuracy.
Zereen, Fahmida; Yilmaz, Vedat; Arslan, Zikri
2013-01-01
A new chelating resin has been synthesized by immobilizing 4–(2–thiazolylazo) resorcinol (TAR) onto styrene divinlybenzene copolymer and examined for on-line solid phase extraction/preconcentration of Cd, Co, Cu, Ni, Pb and Zn in seawater and fish otoliths for determination by inductively plasma mass spectrometry (ICP-MS). A volume of 5.0 mL sample solution was loaded onto the mini column of TAR immobilized resin at 2.0 mL min−1 via a sequential injection system. The optimum pH for multielement preconcentration was around pH 5.5. Recoveries were better than 96% in artificial seawater. Elution was achieved with 1.0 mL of 0.75 mol L−1 HNO3. The resin possesses large sorption capacity ranging from 82.0 µmol g−1 for Pb to 319 µmol g−1 for Cu. The detection limits (3s) varied between 0.0016 µg L−1 (Cd) and to 0.015 µg L−1 (Zn) for preconcentration of 5.0 mL blank solutions (pH 5.5). Relative standard deviation (RSD)for three replicate runs was between 0.3% (Cd) and 6% (Zn) at 1.0 µg L−1 level. The procedure was validated by analysis of Nearshore Seawater certified reference material (CASS–4), and then successfully applied to the determination of the trace elements in fish otoliths (CRM 22) and in coastal seawater and estuarine water samples. PMID:24976635
Pohl, Pawel; Stecka, Helena; Jamroz, Piotr
2014-02-01
A fast and straightforward procedure aimed at separating copper (Cu) ions from monosacharides and preconcentrating their traces before flame atomic absorption spectrometry (FAAS) measurements was developed, and its suitability was evaluated by the analysis of freshly ripened honeys on the content of this environmentally and physiologically relevant element. This procedure included the passage (at 20 mL/min) of 10 % (m/v) solutions of honeys (100 mL) through resin beds of Dowex 50 W × 8-400 to retain Cu by solid-phase extraction (SPE) and separate it from the glucose and fructose matrix. In turn, SPE columns were rinsed at 20 mL/min with 20 mL of water and subsequently washed with 20 mL of a 0.5 mol/L HNO3 solution (at 2.0 mL/min) to elute potassium and sodium. Preconcentrated Cu was stripped (at 2.0 mL/min) with 5.0 mL of a 2.0 mol/L HCl solution and determined by FAAS. The proposed procedure was used for the analysis of six ripened monoflower and multiflower honeys, enabling the measurement of Cu within the range of 0.17-0.42 μg/g and with a precision of 3-10%. Recoveries of Cu added to respective honey solutions were within 94-102%, proving the good accuracy of this procedure. The detection limit of Cu achieved with this SPE preconcentration/separation procedure and FAAS detection was 3.6 ng/g.
Zayats, M F; Leschev, S M; Petrashkevich, N V; Zayats, M A; Kadenczki, L; Szitás, R; Szemán Dobrik, H; Keresztény, N
2013-04-24
Distribution of 150 most widely used pesticides of different chemical classes (amides, anilinopirimidines, aromatics, benzenesulfonates, carbamates, dicarboximides, organophosphorus compounds, phenyl esters, phenylureas, pyrazoles, pyrethroids, pyrimidines, strobilurins, sulfamides, triazines, triazoles, etc.) in n-hexane/water and n-hexane/acetonitrile systems was investigated at 25°C. Distribution constants of pesticides (P) have been calculated as ratio of pesticide concentration in n-hexane to its concentration in water or acetonitrile phase. HPLC and GC methods were used for pesticides determination in phases. It was found that the overwhelming majority of pesticides are hydrophobic, i.e. in n-hexane/water system LgP≫0, and the difference in LgP values can reach 9.1 units. Replacement of water for acetonitrile leads to dramatic fall of LgP values reaching 9.5 units. The majority of LgP values in this case are negative and their differences is strongly leveled in comparison with a hexane/water system. Thus, maximal difference in pesticides LgP values for n-hexane/acetonitrile system is 3.2 units. It is shown that n-hexane can be used for selective and efficient extraction and preconcentration of pesticides from water matrices. On the other hand, acetonitrile is effective for the isolation and preconcentration of pesticides from hydrocarbon and vegetable oil matrices. The distribution constants described in the paper may be effectively used for the estimation of possibilities of extraction isolation, preconcentration and separation of pesticides. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Grate, J. W.; O'Hara, M. J.; Egorov, O. B.; Burge, S. R.
2009-12-01
We have developed automated sensor and analyzer devices for detection and monitoring of trace radionuclides in water, using preconcentrating columns and radiometric detection. The preconcentrating minicolumn sensor concept combines selective capture and detection in a single functional unit, where the column contains tens to hundreds of milligrams of selectively sorbent material, and the entire column content is monitored with a radiometric detector. Compared to thin film sensors with a few microgram of sorbent, this approach achieves tremendous preconcentration with efficient mass transport via pumping. Furthermore, in an equilibration-based mode of operation, the preconcentration by the sensor is maximized while eliminating the need for consumable reagents to regenerate the column; it can simply be re-equilibrated. We have demonstrated quantification of radionuclides such as technetium-99 to levels below drinking water standards in an equilibration-based process that produces steady state signals, signal proportional to concentration, and easy re-equilibration to new concentration levels. Alternatively, analyzers can be developed with separate separation and detection units that are fluidically linked. We have demonstrated detection of strontium-90 to levels below drinking water standards by this approach. We are developing autonomous systems for at-site monitoring on the Hanford Site in Washington State, using the fluidic sensor and analyzer methods, with the aim of monitoring natural and accelerated attenuation processes, remediation and barrier performance, and contaminant fluxes in the environment. Figure 1. The strontium-90 monitoring method deployed as part of the Burge Environmental Universal Sensor Platform, shown on the shores of the Columbia River on the Hanford site in Washington State.
Kartal Temel, Nuket; Gürkan, Ramazan
2018-03-01
A novel ultrasound assisted-cloud point extraction method was developed for preconcentration and determination of V(V) in beverage samples. After complexation by pyrogallol in presence of safranin T at pH 6.0, V(V) ions as ternary complex are extracted into the micellar phase of Triton X-114. The complex was monitored at 533 nm by spectrophotometry. The matrix effect on the recovery of V(V) from the spiked samples at 50 μg L-1 was evaluated. In optimized conditions, the limits of detection and quantification of the method, respectively, was 0.58 and 1.93 μg L-1 in linear range of 2-500 μg L-1 with sensitivity enhancement and preconcentration factors of 47.7 and 40 for preconcentration from 15 mL of sample solution. The recoveries from spiked samples were in range of 93.8-103.2% with a relative standard deviation ranging from 2.6% to 4.1% (25, 100 and 250 μg L-1, n: 5). The accuracy was verified by analysis of two certified samples, and the results were in a good agreement with the certified values. The intra-day and inter-day precision were tested by reproducibility (as 3.3-3.4%) and repeatability (as 3.4-4.1%) analysis for five replicate measurements of V(V) in quality control samples spiked with 5, 10 and 15 μg L-1. Trace V(V) contents of the selected beverage samples by the developed method were successfully determined.
Galbeiro, Rafaela; Garcia, Samara; Gaubeur, Ivanise
2014-04-01
Cloud point extraction (CPE) was used to simultaneously preconcentrate trace-level cadmium, nickel and zinc for determination by flame atomic absorption spectrometry (FAAS). 1-(2-Pyridilazo)-2-naphthol (PAN) was used as a complexing agent, and the metal complexes were extracted from the aqueous phase by the surfactant Triton X-114 ((1,1,3,3-tetramethylbutyl)phenyl-polyethylene glycol). Under optimized complexation and extraction conditions, the limits of detection were 0.37μgL(-1) (Cd), 2.6μgL(-1) (Ni) and 2.3μgL(-1) (Zn). This extraction was quantitative with a preconcentration factor of 30 and enrichment factor estimated to be 42, 40 and 43, respectively. The method was applied to different complex samples, and the accuracy was evaluated by analyzing a water standard reference material (NIST SRM 1643e), yielding results in agreement with the certified values. Copyright © 2013 Elsevier GmbH. All rights reserved.
Li, Yuan; Tian, Rui; Zheng, Xingwang; Huang, Rongfu
2016-08-31
The common drawback of optical methods for rapid detection of nucleic acid by exploiting the differential affinity of single-/double-stranded nucleic acids for unmodified gold nanoparticles (AuNPs) is its relatively low sensitivity. In this article, on the basis of selective preconcentration of AuNPs unprotected by single-stranded DNA (ssDNA) binding, a novel electrochemical strategy for nucleic acid sequence identification assay has been developed. Through detecting the redox signal mediated by AuNPs on 1, 6-hexanedithiol blocked gold electrode, the proposed method is able to ensure substantial signal amplification and a low background current. This strategy is demonstrated for quantitative analysis of the target microRNA (let-7a) in human breast adenocarcinoma cells, and a detection limit of 16 fM is readily achieved with desirable specificity and sensitivity. These results indicate that the selective preconcentration of AuNPs for electrochemical signal readout can offer a promising platform for the detection of specific nucleic acid sequence. Copyright © 2016 Elsevier B.V. All rights reserved.
Zurynková, Pavla; Dědina, Jiří; Kratzer, Jan
2018-06-20
Atomization conditions for antimony hydride in the plasma atomizer based on a dielectric barrier discharge (DBD) with atomic absorption spectrometric detection were optimized. Argon was found as the best discharge gas under a flow rate of 50 mL min - 1 while the DBD power was optimum at 30 W. Analytical figures of merit including interference study of As, Se and Bi have been subsequently investigated and the results compared to those found in an externally heated quartz tube atomizer (QTA). The limit of detection (LOD) reached in DBD (0.15 ng mL -1 Sb) is comparable to that observed in QTA (0.14 ng mL -1 Sb). Finally, possibility of Sb preconcentration by stibane in situ trapping in a DBD atomizer was studied. For trapping time of 300 s, the preconcentration efficiency and LOD, respectively, were 103 ± 2% and 0.02 ng mL -1 . Copyright © 2018 Elsevier B.V. All rights reserved.
Herrero Latorre, C; Barciela García, J; García Martín, S; Peña Crecente, R M
2013-12-04
Selenium is an essential element for the normal cellular function of living organisms. However, selenium is toxic at concentrations of only three to five times higher than the essential concentration. The inorganic forms (mainly selenite and selenate) present in environmental water generally exhibit higher toxicity (up to 40 times) than organic forms. Therefore, the determination of low levels of different inorganic selenium species in water is an analytical challenge. Solid-phase extraction has been used as a separation and/or preconcentration technique prior to the determination of selenium species due to the need for accurate measurements for Se species in water at extremely low levels. The present paper provides a critical review of the published methods for inorganic selenium speciation in water samples using solid phase extraction as a preconcentration procedure. On the basis of more than 75 references, the different speciation strategies used for this task have been highlighted and classified. The solid-phase extraction sorbents and the performance and analytical characteristics of the developed methods for Se speciation are also discussed. Copyright © 2013 Elsevier B.V. All rights reserved.
Chen, Xuwei; Hai, Xin; Wang, Jianhua
2016-05-30
The distinctive/unique electrical, chemical and optical properties make graphene/graphene oxide-based materials popular in the field of analytical chemistry. Its large surface offers excellent capacity to anchor target analyte, making it an powerful sorbent in the adsorption and preconcentration of trace level analyte of interest in the field of sample preparation. The large delocalized π-electron system of graphene framework provides strong affinity to species containing aromatic rings, such as proteins, and the abundant active sites on its surface offers the chance to modulate adsorption tendency towards specific protein via functional modification/decoration. This review provides an overview of the current research on graphene/graphene oxide-based materials as attractive and powerful adsorption media in the separation/isolation and preconcentration of protein species from biological sample matrixes. These practices are aiming at providing protein sample of high purity for further investigations and applications, or to achieve certain extent of enrichment prior to quantitative assay. In addition, the challenges and future perspectives in the related research fields have been discussed. Copyright © 2016 Elsevier B.V. All rights reserved.
Ansari, Ashley J; Hai, Faisal I; Price, William E; Ngo, Huu H; Guo, Wenshan; Nghiem, Long D
2018-07-01
This study assessed the performance and key challenges associated with the integration of forward osmosis (FO) and anaerobic digestion for wastewater treatment and resource recovery. Using a thin film composite polyamide FO membrane, maximising the pre-concentration factor (i.e. system water recovery) resulted in the enrichment of organics and salinity in wastewater. Biomethane potential evaluation indicated that methane production increased correspondingly with the FO pre-concentration factor due to the organic retention in the feed solution. At 90% water recovery, about 10% more methane was produced when using NaOAc compared with NaCl because of the contribution of biodegradable reverse NaOAc flux. No negative impact on anaerobic digestion was observed when wastewater was pre-concentrated ten-fold (90% water recovery) for both draw solutes. Interestingly, the unit cost of methane production using NaOAc was slightly lower than NaCl due to the lower reverse solute flux of NaOAc, although NaCl is a much cheaper chemical. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.
Saljooqi, Asma; Shamspur, Tayebeh; Mohamadi, Maryam; Afzali, Daryoush; Mostafavi, Ali
2015-05-01
First, the extraction and preconcentration of ultratrace amounts of lead(II) ions was performed using microliter volumes of a task-specific ionic liquid. The remarkable properties of ionic liquids were added to the advantages of microextraction procedure. The ionic liquid used was trioctylmethylammonium thiosalicylate, which formed a lead thiolate complex due to the chelating effect of the ortho-positioned carboxylate relative to thiol functionality. So, trioctylmethylammonium thiosalicylate played the roles of both chelating agent and extraction solvent simultaneously. Hence, there is no need to use a ligand. The main parameters affecting the efficiency of the method were investigated and optimized. Under optimized conditions, this approach showed a linear range of 2.0-24.0 ng/mL with a detection limit of 0.0010 ng/mL. The proposed method was applied to the extraction and preconcentration of lead from red lipstick and pine leaves samples prior to electrothermal atomic absorption spectroscopic determination. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Signal Enhancement in HPLC/Micro-Coil NMR Using Automated Column Trapping
Djukovic, Danijel; Liu, Shuhui; Henry, Ian; Tobias, Brian; Raftery, Daniel
2008-01-01
A new HPLC-NMR system is described that performs analytical separation, pre-concentration, and NMR spectroscopy in rapid succession. The central component of our method is the online pre-concentration sequence that improves the match between post-column analyte peak volume and the micro-coil NMR detection volume. Separated samples are collected on to a C18 guard column with a mobile phase composed of 90% D2O/10% acetonitrile-D3, and back-flashed to the NMR micro-coil probe with 90% acetonitrile-D3/10% D2O. In order to assess the performance of our unit, we separated a standard mixture of 1 mM ibuprofen, naproxen, and phenylbutazone using a commercially available C18 analytical column. The S/N measurements from the NMR acquisitions indicated that we achieved signal enhancement factors up to 10.4 (±1.2)-fold. Furthermore, we observed that pre-concentration factors increased as the injected amount of analyte decreased. The highest concentration enrichment of 14.7 (±2.2)-fold was attained injecting 100 μL solution of 0.2 mM (~4 μg) ibuprofen. PMID:17037915
Method and Apparatus for Concentrating Vapors for Analysis
Grate, Jay W.; Baldwin, David L.; Anheier, Jr., Norman C.
2008-10-07
An apparatus and method are disclosed for pre-concentrating gaseous vapors for analysis. The invention finds application in conjunction with, e.g., analytical instruments where low detection limits for gaseous vapors are desirable. Vapors sorbed and concentrated within the bed of the apparatus can be thermally desorbed achieving at least partial separation of vapor mixtures. The apparatus is suitable, e.g., for preconcentration and sample injection, and provides greater resolution of peaks for vapors within vapor mixtures, yielding detection levels that are 10-10,000 times better than for direct sampling and analysis systems. Features are particularly useful for continuous unattended monitoring applications.
Khan, Sumaira; Soylak, Mustafa; Kazi, Tasneem Gul
2013-12-01
The current work develops a new green methodology for the separation/preconcentration of cadmium ions (Cd(2+)) using room temperature ionic liquid-dispersive liquid phase microextraction (RTIL-DLME) prior to analysis by flame atomic absorption spectrometry with microsample introduction system. Room temperature ionic liquids (RTIL) are considered "Green Solvents" for their thermally stable and non-volatile properties, here 1-butyl-3-methylimidazolium hexafluorophosphate [C4mim][PF6] was used as an extractant. The preconcentration of Cd(2+) in different waters and acid digested scalp hair samples were complexed with 1-(2-pyridylazo)-2-naphthol and extracted into the fine drops of RTILs. Some significant factors influencing the extraction efficiency of Cd(2+) and its subsequent determination, including pH, amount of ligand, volume of RTIL, dispersant solvent, sample volume, temperature, and incubation time were investigated in detail. The limit of detection and the enhancement factor under the optimal conditions were 0.05 μg/L and 50, respectively. The relative standard deviation of 100 μg/L Cd(2+) was 4.3 %. The validity of the proposed method was checked by determining Cd(2+) in certified reference material (TM-25.3 fortified water). The sufficient recovery (>98 %) of Cd(2+) with the certified value. The mean concentrations of Cd in lake water 13.2, waste water 15.7 and hair sample 16.8 μg/L, respectively and the developed method was applied satisfactorily to the preconcentration and determination of Cd(2+) in real samples.
NASA Astrophysics Data System (ADS)
Wu, Hong; Jin, Yan; Han, Weiying; Miao, Qiang; Bi, Shuping
2006-07-01
A novel non-chromatographic approach for direct speciation of mercury, based on the selective retention inorganic mercury and methylmercury on the inner wall of a knotted reactor by using ammonium diethyl dithiophosphate and dithizone as complexing agents respectively, was developed for flow injection on-line sorption preconcentration coupled with chemical vapor generation non-dispersive atomic fluorescence spectrometry. With the sample pH kept at 2.0, the preconcentration of inorganic mercury on the inner walls of the knotted reactor was carried out based on the exclusive retention of Hg-DDP complex in the presence of methylmercury via on-line merging the sample solution with ammonium diethyl dithiophosphate solution, and selective preconcentration methylmercury was achieved with dithizone instead of ammonium diethyl dithiophosphate. A 15% (v/v) HCl was introduced to elute the retained mercury species and merge with KBH 4 solution for atomic fluorescence spectrometry detection. Under the optimal experimental conditions, the sample throughputs of inorganic mercury and methylmercury were 30 and 20 h - 1 with the enhancement factors of 13 and 24. The detection limits were found to be 3.6 ng l - 1 for Hg 2+ and 2.0 ng l - 1 for CH 3Hg +. The precisions (RSD) for the 11 replicate measurements of each 0.2 μg l - 1 of Hg 2+ and CH 3Hg + were 2.2% and 2.8%, respectively. The developed method was validated by the analysis of certified reference materials (simulated natural water, rice flour and pork) and by recovery measurements on spiked samples, and was applied to the determination of inorganic mercury and methylmercury in biological and environmental water samples.
Fiel, Somewhere A; Yang, Hua; Schaffer, Paul; Weng, Samuel; Inkster, James A H; Wong, Michael C K; Li, Paul C H
2015-06-17
The radioisotope 18F is often considered the best choice for positron emission tomography (PET) owing to its desirable chemical and radiochemical properties. However, nucleophilic 18F-fluorination of large, water-soluble biomolecules, based on C-F bond formation, has traditionally been difficult. Thus, several aqueous fluorination approaches that offer significant versatility in radiopharmaceutical synthesis with sensitive targeting vectors have been developed. Furthermore, because 18F decays rapidly, production of these 18F-labeled compounds requires an automated process to reduce production time, reduce radiation exposure, and minimize losses due to the transfer of reagents during tracer synthesis. Herein, we report the use of magnetic droplet microfluidics (MDM) as a means to concentrate [18F]fluoride from the cyclotron target solution, followed by the synthesis of an 18F-labeled compound on a microfluidic platform. Using this method, we have demonstrated 18F preconcentration in a small-volume droplet through the use of anion exchanging magnetic particles. By using MDM, the preconcentration step took approximately 5 min, and the [18F]fluoride solution was preconcentrated by 15-fold. After the preconcentration step, an 18F-labeling reaction was performed on the MDM platform using the S-F bond formation in aqueous conditions to produce an arylsulfonyl [18F]fluoride compound which can be used as a prosthetic group to label PET targeting ligands. The high radiochemical purity of 95±1% was comparable to the 96% previously reported using a conventional method. In addition, when MDM was used, the total synthesis time was improved to 15 min with lower reagent volumes (50-60 μL) used.
Narcise, Cristine Ingrid S; Coo, Lilibeth Dlc; Del Mundo, Florian R
2005-12-15
A flow injection-column preconcentration-hydride generation atomic absorption spectrophotometric (FI-column-HGAAS) method was developed for determining mug/l levels of As(III) and As(V) in water samples, with simultaneous preconcentration and speciation. The speciation scheme involved determining As(V) at neutral pH and As(III+V) at pH 12, with As(III) obtained by difference. The enrichment factor (EF) increased with increase in sample loading volume from 2.5 to 10ml, and for preconcentration using the chloride-form anion exchange column, EFs ranged from 5 to 48 for As(V) and 4 to 24 for As(III+V), with corresponding detection limits of 0.03-0.3 and 0.07-0.3mug/l. Linear concentration range (LCR) also varied with sample loading volume, and for a 5-ml sample was 0.3-5 and 0.2-8mug/l for As(V) and As(III+V), respectively. Sample throughput, which decreased with increase in sample volume, was 8-17 samples/h. For the hydroxide-form column, the EFS for 2.5-10ml samples were 3-23 for As(V) and 2-15 for As(III+V), with corresponding detection limits of 0.07-0.4 and 0.1-0.5mug/l. The LCR for a 5-ml sample was 0.3-10mug/l for As(V) and 0.2-20mug/l for As(III+V). Sample throughput was 10-20 samples/h. The developed method has been effectively applied to tap water and mineral water samples, with recoveries ranging from 90 to 102% for 5-ml samples passed through the two columns.
Krawczyk-Coda, Magdalena; Stanisz, Ewa
2017-11-01
This work presents ultrasound-assisted dispersive micro solid phase extraction (USA DMSPE) for preconcentration of fluorine (F) in water and herb samples. TiO 2 nanoparticles (NPs) were used as an adsorbent. The determination with slurry sampling was performed via molecular absorption of calcium monofluoride (CaF) at 606.440 nm using a high-resolution continuum source electrothermal absorption spectrometry (HR-CS ET MAS). Several factors influencing the efficiency of the preconcentration technique, such as the amount of TiO 2 , pH of sample solution, ultrasonication and centrifugation time and TiO 2 slurry solution preparation before injection to HR-CS ET MAS, were investigated in detail. The conditions of detection step (wavelength, calcium amount, pyrolysis and molecule-forming temperatures) were also studied. After extraction, adsorbent with the analyte was mixed with 200 μL of H 2 O to prepare a slurry solution. The concentration limit of detection was 0.13 ng mL -1 . The achieved preconcentration factor was 7. The relative standard deviations (RSDs, %) for F in real samples were 3-15%. The accuracy of this method was evaluated by analyses of certified reference materials after spiking: INCT-MPH-2 (Mixed Polish Herbs), INCT-SBF-4 (Soya Bean Flour), ERM-CAO11b (Hard Drinking Water) and TMDA-54.5 (Lake Ontario Water). The measured F contents in reference materials were in satisfactory agreement with the added amounts, and the recoveries were found to be 97-109%. Under the developed extraction conditions, the proposed method has been successfully applied for the determination of F in real water samples (lake, sea, tap water) and herbs.
Human portable preconcentrator system
Linker, Kevin L.; Bouchier, Francis A.; Hannum, David W.; Rhykerd, Jr., Charles L.
2003-01-01
A preconcentrator system and apparatus suited to human portable use wherein sample potentially containing a target chemical substance is drawn into a chamber and through a pervious screen. The screen is adapted to capture target chemicals and then, upon heating, to release those chemicals into the chamber. Chemicals captured and then released in this fashion are then carried to a portable chemical detection device such as a portable ion mobility spectrometer. In the preferred embodiment, the means for drawing sample into the chamber comprises a reversible fan which, when operated in reverse direction, creates a backpressure that facilitates evolution of captured target chemicals into the chamber when the screen is heated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cong, Yongzheng; Rausch, Sarah J.; Geng, Tao
2014-10-27
Here we show that a closed pneumatic microvalve on a PDMS chip can serve as a semipermeable membrane under an applied potential, enabling current to pass through while blocking the passage of charged analytes. Enrichment of both anionic and cationic species has been demonstrated, and concentration factors of ~70 have been achieved in just 8 s. Once analytes are concentrated, the valve is briefly opened and the sample is hydrodynamically injected onto an integrated microchip or capillary electrophoresis (CE) column. In contrast to existing preconcentration approaches, the membrane-based method described here enables both rapid analyte concentration as well as highmore » resolution separations.« less
Feng, Qin-Zhong; Zhao, Li-Xia; Yan, Wei; Lin, Jin-Ming; Zheng, Zhi-Xia
2009-08-15
The molecularly imprinted bulk polymer with 2,4,6-trichlorophenol (2,4,6-TCP) as the template molecule and methylacrylic acid (MAA), ethylene glycol dimethacrylate (EGDMA) as functional monomer and the crosslinker, respectively, has been prepared and applied to the molecularly imprinted solid-phase extraction (MISPE) procedure for selective preconcentration of phenolic compounds from environmental water samples. Various parameters affecting the extraction efficiency of the polymer have been evaluated to optimize the selective preconcentration of the phenolic compounds from aqueous samples. The characteristics of the MISPE method were validated by HPLC. The recoveries ranged between 90% and 98% (RSD: 0.9-2.3%, n=3) for tap water, between 85% and 105% (RSD: 2.6-4.9%, n=3) for river water, between 78% and 98% (RSD: 2.6-5.4%, n=3) for sewage water fortified with 0.4 mg L(-1) of phenol, 4-chlorophenol (4-CP), 2,4-dichlorophenol (2,4-DCP), pentachlorophenol (PCP). It was demonstrated that this MISPE-HPLC method could be applied to direct preconcentration and determination of phenolic compounds in environmental water samples.
Daşbaşı, Teslima; Saçmacı, Şerife; Çankaya, Nevin; Soykan, Cengiz
2016-11-15
In this study, a simple and rapid solid phase extraction/preconcentration procedure was developed for determination of Cd(II), Co(II), Cr(III), Cu(II), Fe(III), Mn(II), Pb(II), and Zn(II) trace metals by flame atomic absorption spectrometry (FAAS). A new chelating resin, poly(N-cyclohexylacrylamide-co-divinylbenzene-co-2-acrylamido-2-methyl-1-propanesulfonic acid) (NCA-co-DVB-co-AMPS) (hereafter CDAP) was synthesized and characterized. The influences of the analytical parameters such as pH of the sample solution, type and concentration of eluent, flow rates of the sample and eluent, volume of the sample and eluent, amount of chelating resin, and interference of ions were examined. The limit of detection (LOD) of analytes were found (3s) to be in the range of 0.65-1.90μgL(-1). Preconcentration factor (PF) of 200 and the relative standard deviation (RSD) of ⩽2% were achieved (n=11). The developed method was applied for determination of analytes in some dairy samples and certified reference materials. Copyright © 2016 Elsevier Ltd. All rights reserved.
Feist, Barbara; Mikula, Barbara; Pytlakowska, Katarzyna; Puzio, Bozena; Buhl, Franciszek
2008-04-15
The applicability of 2,2'-bipyridyl and erythrosine co-precipitation method for the separation and preconcentration of some heavy metals, such as Cd, Co, Cu, Ni, Pb and Zn in actual samples for their determination by ICP-OES and F-AAS was studied. Experimental conditions influencing the recovery of the investigated metals, such as pH, molar ratio of 2,2'-bipyridyl to erythrosine, the effect of time on co-precipitation were optimized. The analytical characteristics of the method (e.g. limit of detection, sensitivity, linear range and preconcentration factor) were obtained. The limits of detection LOD (ng mL(-1)) of the ICP-OES (F-AAS) method were: Cd: 4.0 (7.75), Co: 3.1 (57.2), Cu: 18 (10.3), Ni 21.3 (32.8), Pb: 35.9 (29.2) and Zn: 10.2 (6.90). The recovery of all the elements tested was more than 93%. The influence of inorganic matrix was examined. The proposed method was applied to determination of Cd, Co, Cu, Ni, Pb and Zn in vegetables and certified reference material (NCS ZC85006 Tomato).
See, Hong Heng; Hauser, Peter C; Ibrahim, Wan Aini Wan; Sanagi, Mohd Marsin
2010-01-01
Rapid and direct online preconcentration followed by CE with capacitively coupled contactless conductivity detection (CE-C(4)D) is evaluated as a new approach for the determination of glyphosate, glufosinate (GLUF), and aminophosphonic acid (AMPA) in drinking water. Two online preconcentration techniques, namely large volume sample stacking without polarity switching and field-enhanced sample injection, coupled with CE-C(4)D were successfully developed and optimized. Under optimized conditions, LODs in the range of 0.01-0.1 microM (1.7-11.1 microg/L) and sensitivity enhancements of 48- to 53-fold were achieved with the large volume sample stacking-CE-C(4)D method. By performing the field-enhanced sample injection-CE-C(4)D procedure, excellent LODs down to 0.0005-0.02 microM (0.1-2.2 microg/L) as well as sensitivity enhancements of up to 245- to 1002-fold were obtained. Both techniques showed satisfactory reproducibility with RSDs of peak height of better than 10%. The newly established approaches were successfully applied to the analysis of glyphosate, glufosinate, and aminophosphonic acid in spiked tap drinking water.
Li, Zhenhua; Chang, Xijun; Hu, Zheng; Huang, Xinping; Zou, Xiaojun; Wu, Qiong; Nie, Rong
2009-07-15
A new method that utilizes zincon-modified activated carbon (AC-ZCN) as a solid-phase extractant has been developed for simultaneous preconcentration of trace Cr(III) and Pb(II) prior to the measurement by inductively coupled plasma optical emission spectrometry (ICP-OES). The separation/preconcentration conditions of analytes were investigated, including effects of pH, the shaking time, the sample flow rate and volume, the elution condition and the interfering ions. At pH 4, the maximum adsorption capacity of Cr(III) and Pb(II) onto the AC-ZCN were 17.9 and 26.7 mg g(-1), respectively. The adsorbed metal ions were quantitatively eluted by 1 mL of 0.1 mol L(-1) HCl. Common coexisting ions did not interfere with the separation. According to the definition of IUPAC, the detection limits (3 sigma) of this method for Cr(III) and Pb(II) were 0.91 and 0.65 ng mL(-1), respectively. The relative standard deviation under optimum condition is less than 3.5% (n=8). The method has been applied for the determination of Cr(III) and Pb(II) in biological materials and water samples with satisfactory results.
Kubo, Takuya; Kuroda, Kenta; Tominaga, Yuichi; Naito, Toyohiro; Sueyoshi, Kenji; Hosoya, Ken; Otsuka, Koji
2014-02-01
We report an effective and a quantitative analysis method for one of pharmaceuticals, sulpiride, in river water by online solid phase extraction (SPE) connected with liquid chromatography-mass spectrometry (LC-MS) using a molecularly imprinted polymer as a preconcentration medium. The polymer prepared with a pseudo template molecule showed the selective retention ability based on the interval recognition of functional groups in sulpiride. Also, the imprinted polymer provided an effective concentration of a trace level of sulpiride in offline SPE with dual washing processes using water and acetonitrile, although another imprinted polymer prepared by an authentic method using sulpiride and methacrylic acid as a template and a functional monomer, respectively, showed the selective adsorption only in organic solvents. Furthermore, we employed the imprinted polymer as the preconcentration column of online SPE-LC-MS and the results supposed that the proposed system allowed the quantitative analysis of sulpiride with high sensitivity and recovery (10ng/L at 96%). Additionally, the determination of sulpiride in real river water without an additional spiking was effectively achieved by the system. Copyright © 2013 Elsevier B.V. All rights reserved.
Asadollahi, Tahereh; Dadfarnia, Shayessteh; Shabani, Ali Mohammad Haji
2010-06-30
A novel dispersive liquid-liquid microextraction based on solidification of floating organic drop (DLLME-SFO) for separation/preconcentration of ultra trace amount of vanadium and its determination with the electrothermal atomic absorption spectrometry (ETAAS) was developed. The DLLME-SFO behavior of vanadium (V) using N-benzoyl-N-phenylhydroxylamine (BPHA) as complexing agent was systematically investigated. The factors influencing the complex formation and extraction by DLLME-SFO method were optimized. Under the optimized conditions: 100 microL, 200 microL and 25 mL of extraction solvent (1-undecanol), disperser solvent (acetone) and sample volume, respectively, an enrichment factor of 184, a detection limit (based on 3S(b)/m) of 7 ng L(-1) and a relative standard deviation of 4.6% (at 500 ng L(-1)) were obtained. The calibration graph using the preconcentration system for vanadium was linear from 20 to 1000 ng L(-1) with a correlation coefficient of 0.9996. The method was successfully applied for the determination of vanadium in water and parsley. Copyright 2010 Elsevier B.V. All rights reserved.
A fully-integrated aptamer-based affinity assay platform for monitoring astronaut health in space.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Xianbin; Durland, Ross H.; Hecht, Ariel H.
2010-07-01
Here we demonstrate the suitability of robust nucleic acid affinity reagents in an integrated point-of-care diagnostic platform for monitoring proteomic biomarkers indicative of astronaut health in spaceflight applications. A model thioaptamer targeting nuclear factor-kappa B (NF-{kappa}B) is evaluated in an on-chip electrophoretic gel-shift assay for human serum. Key steps of (i) mixing sample with the aptamer, (ii) buffer exchange, and (iii) preconcentration of sample were successfully integrated upstream of fluorescence-based detection. Challenges due to (i) nonspecific interactions with serum, and (ii) preconcentration at a nanoporous membrane are discussed and successfully resolved to yield a robust, rapid, and fully-integrated diagnostic system.
Foster, G.D.; Foreman, W.T.; Gates, Paul M.
1991-01-01
The reliability of the Goulden large-sample extractor in preconcentrating pesticides from water was evaluated from the recoveries of 35 pesticides amended to filtered stream waters. Recoveries greater than 90% were observed for many of the pesticides in each major chemical class, but recoveries for some of the individual pesticides varied in seemingly unpredictable ways. Corrections cannot yet be factored into liquid-liquid extraction theory to account for matrix effects, which were apparent between the two stream waters tested. The Goulden large-sample extractor appears to be well suited for rapid chemical screening applications, with quantitative analysis requiring special quality control considerations. ?? 1991 American Chemical Society.
Csiktusnádi Kiss, G A; Forgács, E; Cserháti, T; Candeias, M; Vilas-Boas, L; Bronze, R; Spranger, I
2000-08-11
The adsorption and desorption capacities of 11 different solid-phase extraction sorbents were tested for the preconcenration of pigments of various Hungarian red wines. The concentrates were evaluated by multiwavelengh spectrophotometry combined with a spectral mapping technique (SPM) and by reversed-phase high-performance liquid chromatography. The highest (10-fold) concentration of pigments was achieved on octadecylsilica sorbent. It can be used five times without losing adsorption and desorption characteristics. SPM indicated that multiwavelength spectrophotometry can be employed for the differentiation of red wines. Comparison of the chromatograms of pigments with and without preconcentration showed that preconcentration makes possible the separation and detection of pigments present in low concentration in red wines.
Analytical Applications of Transport Through Bulk Liquid Membranes.
Diaconu, Ioana; Ruse, Elena; Aboul-Enein, Hassan Y; Bunaciu, Andrei A
2016-07-03
This review discusses the results of research in the use of bulk liquid membranes in separation processes and preconcentration for analytical purposes. It includes some theoretical aspects, definitions, types of liquid membranes, and transport mechanism, as well as advantages of using liquid membranes in laboratory studies. These concepts are necessary to understand fundamental principles of liquid membrane transport. Due to the multiple advantages of liquid membranes several studies present analytical applications of the transport through liquid membranes in separation or preconcentration processes of metallic cations and some organic compounds, such as phenol and phenolic derivatives, organic acids, amino acids, carbohydrates, and drugs. This review presents coupled techniques such as separation through the liquid membrane coupled with flow injection analysis.
Rapid method for the determination of 226Ra in hydraulic fracturing wastewater samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maxwell, Sherrod L.; Culligan, Brian K.; Warren, Richard A.
A new method that rapidly preconcentrates and measures 226Ra from hydraulic fracturing wastewater samples was developed in the Savannah River Environmental Laboratory. The method improves the quality of 226Ra measurements using gamma spectrometry by providing up to 100x preconcentration of 226Ra from this difficult sample matrix, which contains very high levels of calcium, barium, strontium, magnesium and sodium. The high chemical yield, typically 80-90%, facilitates a low detection limit, important for lower level samples, and indicates method ruggedness. Ba-133 tracer is used to determine chemical yield and correct for geometry-related counting issues. The 226Ra sample preparation takes < 2 hours.
Motooka, J.M.
1988-01-01
An atomic absorption extraction technique which is widely used in geochemical exploration for the determination of Ag, As, Au, Bi, Cd, Cu, Mo, Pb, Sb, and Zn has been modified and adapted to a simultaneous inductively coupled plasma-atomic emission instrument. the experimental and operating parameters are described for the preconcentration of the metals into their organometallic halides and for the determination of the metals. Lower limits of determination are equal to or improved over those for flame atomic absorption (except Au) and ICP results are very similar to the accepted AA values, with precision for the ICP data in excess of that necessary for exploration purposes.
Rapid method for the determination of 226Ra in hydraulic fracturing wastewater samples
Maxwell, Sherrod L.; Culligan, Brian K.; Warren, Richard A.; ...
2016-03-24
A new method that rapidly preconcentrates and measures 226Ra from hydraulic fracturing wastewater samples was developed in the Savannah River Environmental Laboratory. The method improves the quality of 226Ra measurements using gamma spectrometry by providing up to 100x preconcentration of 226Ra from this difficult sample matrix, which contains very high levels of calcium, barium, strontium, magnesium and sodium. The high chemical yield, typically 80-90%, facilitates a low detection limit, important for lower level samples, and indicates method ruggedness. Ba-133 tracer is used to determine chemical yield and correct for geometry-related counting issues. The 226Ra sample preparation takes < 2 hours.
Islam, Aminul; Ahmad, Akil; Laskar, Mohammad Asaduddin
2015-01-01
Amberlite® XAD-16 was functionalized with p-aminobenzene sulfonic acid via an azo spacer in order to prepare a new chelating resin, which was then characterized by water regain value, hydrogen ion capacity, elemental analyses, and IR spectral and thermal studies. The maximum uptake of Cu(II), Ni(II), Zn(II), Co(II), Cr(III), Fe(III), and Pb(II) ions was observed in the pH range 4.0-6.0 with the corresponding half-loading times of 6.5, 7.0, 8.0, 9.0, 11.0, 8.5, and 16.5 min. The sorption data followed Langmuir isotherms and a pseudo-second-order model. Thermodynamic quantities, ΔH and ΔS, based on the variation of the distribution coefficient with temperature were also evaluated. High preconcentration factors of 60-100 up to a low preconcentration limit of 4.0-6.6 μg/L have been achieved for the metal ions. The validity of the method was checked by analyzing standard reference materials and recoveries of trace metals after spiking. The analytical applications of the method were explored by analyzing natural water, mango pulp, mint leaves, and fish.
Manoochehri, Mahboobeh; Asgharinezhad, Ali Akbar; Shekari, Nafiseh
2015-01-01
This work describes a novel Fe₃O₄@SiO₂@polyaminoquinoline magnetic nanocomposite and its application in the pre-concentration of Cd(II) and Pb(II) ions. The parameters affecting the pre-concentration procedure were optimised by a Box-Behnken design through response surface methodology. Three variables (extraction time, magnetic sorbent amount and pH) were selected as the main factors affecting the sorption step, while four variables (type, volume and concentration of the eluent, and elution time) were selected as main factors in the optimisation study of the elution step. Following the sorption and elution of analytes, the ions were quantified by flame atomic absorption spectrometry (FASS). The limits of detection were 0.1 and 0.7 ng ml(-1) for Cd(II) and Pb(II) ions, respectively. All the relative standard deviations were less than 7.6%. The sorption capacities of this new sorbent were 57 mg g(-)(1) for Cd(II) and 73 mg g(-1) for Pb(II). Ultimately, this nanocomposite was successfully applied to the rapid extraction of trace quantities of these heavy metal ions from seafood and agricultural samples and satisfactory results were obtained.
Christou, Chrysoula K; Anthemidis, Aristidis N
2009-04-15
A novel flow injection (FI) on-line displacement solid phase extraction preconcentration and/or separation method coupled with FAAS in order to minimize interference from other metals was developed for trace silver determination. The proposed method involved the on-line formation and subsequently pre-sorption of lead diethyldithiocarbamate (Pb-DDTC) into a column packed with PTFE-turnings. The preconcentration and/or separation of the Ag(I) took place through a displacement reaction between Ag(I) and Pb(II) of the pre-sorbed Pb-DDTC. Finally, the retained analyte was eluted with isobutyl methyl ketone (IBMK) and delivered directly to nebulizer for measuring. Interference from co-existing ions with lower DDTC complex stability in comparison with Pb-DDTC, was eliminated without need for any masking reagent. With 120 s of preconcentration time at a sample flow rate of 7.6 mL min(-1), an enhancement factor of 110 and a detection limit (3s) of 0.2 microg L(-1) were obtained. The precision (RSD, n=10) was 3.1% at the 10 mug L(-1) level. The developed method was successfully applied to trace silver determination in a variety of environmental water samples and certified reference material.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dietz, M. L.
1998-11-30
The determination of low levels of radionuclides in environmental and biological samples is often hampered by the complex and variable nature of the samples. One approach to circumventing this problem is to incorporate into the analytical scheme a separation and preconcentration step by which the species of interest can be isolated from the major constituents of the sample. Extraction chromatography (EXC), a form of liquid chromatography in which the stationary phase comprises an extractant or a solution of an extractant in an appropriate diluent coated onto an inert support, provides a simple and efficient means of performing a wide varietymore » of metal ion separations. Recent advances in extractant design, in particular the development of extractants capable of metal ion recognition or of strong complex formation even in acidic media, have substantially improved the utility of the method. For the preconcentration of actinides, for example, an EXC resin consisting of a liquid diphosphonic acid supported on a polymeric substrate has been shown to exhibit extraordinarily strong retention of these elements from acidic chloride media. This resin, together with other related materials, can provide the basis of a number of efficient and flexible schemes for the separation and preconcentration of radionuclides form a variety of samples for subsequent determination.« less
Zhao, Yong-Gang; Zhang, Yun; Wang, Feng-Lian; Zhou, Jian; Zhao, Qi-Ming; Zeng, Xiu-Qiong; Hu, Mei-Qin; Jin, Mi-Cong; Zhu, Yan
2018-08-01
The novel quaternary ammonium modified magnetic carboxyl-carbon nanotubes (QA-Mag-CCNTs) have been synthesised and characterized. QA-Mag-CCNTs were applied in magnetic dispersive solid phase extraction (Mag-dSPE) for preconcentration of perchlorate from tea leaves prior to liquid chromatography-tandem quadrupole mass spectrometry (LC-MS/MS) analysis. The Mag-dSPE procedure for preconcentration of perchlorate succeed in overcoming the flaw (containing target analyte randomly) of commercially available SPE cartridge. Under optimal conditions, the results showed higher extraction efficiency of QA-Mag-CCNTs, with recoveries between 85.2% and 107%. And the satisfactory precision with inter-day and intra-day RSD values were lower than 8.0%. Furthermore, QA-Mag-CCNTs were evaluated for reuse up to 20 times. The limit of quantification (LOQ) for perchlorate was 8.21 ng kg -1 . The developed method was successfully applied in tea leaves for food-safety risk monitoring in Zhejiang province, China. The results showed the concentrations of perchlorate in 229 out of 240 collected samples were in the range of 0.082-988 μg kg -1 . It was confirmed that QA-Mag-CCNTs were highly effective materials used for preconcentration of perchlorate. Copyright © 2018 Elsevier B.V. All rights reserved.
Ozdemir, Sadin; Kilinc, Ersin; Celik, Kadir Serdar; Okumus, Veysi; Soylak, Mustafa
2017-01-15
A novel solid phase extraction method was developed for simultaneous preconcentration-separation of Co(2+), Cr(6+), Hg(2+) and Pb(2+) ions prior to their determinations in food samples by ICP-OES. Thermophilic Bacillus altitudinis immobilized nanodiamond was used as a new biosorbent. SEM and FT-IR analysis were studied to characterize the biosorbent. The optimum pH values of quantitative biosorption for Co(2+), Cr(6+), Hg(2+) and Pb(2+) were found to be 5.0, 6.0, 6.0 and 6.0, respectively. A flow rate of 3.0mLmin(-1) was selected as optimum for all metal ions. 5mL of 1mol/L HCl was used as eluent. Preconcentration factor was achieved as 80. LODs were calculated as 0.071, 0.023, 0.016 and 0.034ngmL(-1), respectively for Hg(2+), Co(2+), Cr(6+) and Pb(2+). The biosorption capacities were calculated for Co(2+), Cr(6+), Hg(2+) and Pb(2+) as 26.4, 30.4, 19.5, and 35.2mg/g, respectively. The developed method was successfully applied to food samples to determine analyte concentrations. Copyright © 2016. Published by Elsevier Ltd.
Ensafi, Ali A; Shiraz, A Zendegi
2008-02-11
Activated carbon loaded with xylenol orange in a mini-column was used for the highly selective separation and preconcentration of Pb(II) ions. An on-line system for enrichment and the determination of Pb(II) was carried out on flame atomic absorption spectrometry. The conditions of preconcentration and quantitative recovery of Pb(II) from diluted solution, such as pH of aqueous phase, amount of the sorbent, volume of the solutions and flow variables were studied as well as effect of potential interfering ions. Under the optimum conditions, Pb(II) in an aqueous sample was concentrated about 200-fold and the detection limit was 0.4 ng mL(-1) Pb(II). The adsorption capacity of the solid phase was 0.20mg of lead per one gram of the modified activated carbon. The modified activated carbon is stable for several treatments of sample solutions without the need for using any chemical reagent. The recovery of lead(II) from river water, waste water, tap water, and in the following reference materials: SRM 2711 Montana soil and GBW-07605 tea were obtained in the range of 97-104% by the proposed method.
Dakova, Ivanka; Karadjova, Irina; Ivanov, Ivo; Georgieva, Ventsislava; Evtimova, Bisera; Georgiev, George
2007-02-12
Ion-imprinted polymer (IIP) particles are prepared by copolymerization of methacrylic acid as monomer, trimethylolpropane trimethacrylate as crosslinking agent and 2,2'-azo-bis-isobutyronitrile as initiator in the presence of Cu(II), a Cu(II)-4-(2-pyridylazo)resorcinol (Cu(II)-PAR) complex, and PAR only. A batch procedure is used for the determination of the characteristics of the Cu(II) solid phase extraction from the IIP produced. The results obtained show that the Cu(II)-PAR IIP has the greatest adsorption capacity (37.4 micromol g(-1) of dry copolymer) among the IIPs investigated. The optimal pH value for the quantitative preconcentration is 7, and full desorption is achieved by 1 M HNO(3). The selectivity coefficients (S(Cu/Me)) for Me=Ni(II), Co(II) are 45.0 and 38.5, respectively. It is established that Cu(II)-PAR IIPs can be used repeatedly without a considerable adsorption capacity loss. The determination of Cu(II) ions in seawater shows that the interfering matrix does not influence the preconcentration and selectivity values of the Cu(II)-PAR IIPs. The detection and quantification limits are 0.001 micromol L(-1) (3sigma) and 0.003 micromol L(-1) (6sigma), respectively.
Okumura, M; Tong, L; Fujinaga, K; Seike, Y
2001-05-01
A simple and rapid in situ preconcentration method for the determination of phosphate in environmental waters has been developed for field analysis. This method is based on solid-phase extraction on a zirconium-loaded Sep-Pack Accell CM cartridge (Zr-SP) and is applicable to studies in which sampling is performed by use of a graduated syringe to prevent contamination and to ensure easy operation at sampling sites. The Zr-SP cartridge was prepared by passing 0.1 mol L(-1) zirconium solution through a Sep-Pak Accell CM cartridge, packed with cation exchange sorbent based on a silica matrix. The adsorption of phosphate and its desorption depend only on the pH of the solution. A water sample containing phosphate was adjusted to pH 2 and passed through the Zr-SP cartridge to collect it. The retained phosphate was quantitatively eluted with 0.5 mol L(-1) sodium hydroxide solution. The phosphate retained in the Zr-SP cartridge was stable for at least one month. The established preconcentration method was successfully applied to brackish lake waters to investigate seasonal changes in the distribution and behavior of phosphate in a brackish lake.
Wu, Chung-Shu; Liu, Fu-Ken; Ko, Fu-Hsiang
2011-01-01
Nanoparticle-based material is a revolutionary scientific and engineering venture that will invariably impact the existing analytical separation and preconcentration for a variety of analytes. Nanoparticles can be regarded as a hybrid between small molecule and bulk material. A material on the nanoscale produces considerable changes on various properties, making them size- and shape-dependent. Gold nanoparticles (Au NPs), one of the wide variety of core materials available, coupled with tunable surface properties in the form of inorganic or inorganic-organic hybrid have been reported as an excellent platform for a broad range of analytical methods. This review aims to introduce the basic principles, examples, and descriptions of methods for the characterization of Au NPs by using chromatography, electrophoresis, and self-assembly strategies for separation science. Some of the latest important applications of using Au NPs as stationary phases toward open-tubular capillary electrochromatography, gas chromatography, and liquid chromatography as well as roles of run buffer additive to enhance separation and preconcentration in the field of chromatographic, electrophoretic and in chip-based systems are reviewed. Additionally, we review Au NPs-assisted state-of-the-art techniques involving the use of micellar electrokinetic chromatography, an online diode array detector, solid-phase extraction, and mass spectrometry for the preconcentration of some chemical compounds and biomolecules.
NASA Astrophysics Data System (ADS)
Mirabi, Ali; Dalirandeh, Zeinab; Rad, Ali Shokuhi
2015-05-01
A new method has been developed for the separation/preconcentration of trace level cadmium ions using diphenyl carbazone/sodium dodecyl sulfate immobilized on magnetic nanoparticle Fe3O4 as a new sorbent SPE and their determination by flame atomic absorption spectrometry (FAAS). Synthesized nanoparticle was characterized by scanning electron microscope (SEM) and transmission electron microscope (TEM). Various influencing parameters on the separation and preconcentration of trace level cadmium ions such as, pH value, amount of nanoparticles, amount of diphenyl carbazone, condition of eluting solution, the effects of matrix ions were examined. The cadmium ions can be eluted from the modified magnetic nanoparticle using 1 mol L-1 HCl as a desorption reagent. The detection limit of this method for cadmium was 3.71 ng ml-1 and the R.S.D. was 0.503% (n=6). The advantages of this new method include rapidity, easy preparation of sorbents and a high concentration factor. The proposed method has been applied to the determination of Cd ions at trace levels in real samples such as, green tea, rice, tobacco, carrot, lettuce, ginseng, spice, tap water, river water, sea water with satisfactory results.
NASA Astrophysics Data System (ADS)
Obersteiner, Florian; Bönisch, Harald; Keber, Timo; O'Doherty, Simon; Engel, Andreas
2016-10-01
We present a compact and versatile cryofocusing-thermodesorption unit, which we developed for quantitative analysis of halogenated trace gases in ambient air. Possible applications include aircraft-based in situ measurements, in situ monitoring and laboratory operation for the analysis of flask samples. Analytes are trapped on adsorptive material cooled by a Stirling cooler to low temperatures (e.g. -80 °C) and subsequently desorbed by rapid heating of the adsorptive material (e.g. +200 °C). The set-up involves neither the exchange of adsorption tubes nor any further condensation or refocusing steps. No moving parts are used that would require vacuum insulation. This allows for a simple and robust design. Reliable operation is ensured by the Stirling cooler, which neither contains a liquid refrigerant nor requires refilling a cryogen. At the same time, it allows for significantly lower adsorption temperatures compared to commonly used Peltier elements. We use gas chromatography - mass spectrometry (GC-MS) for separation and detection of the preconcentrated analytes after splitless injection. A substance boiling point range of approximately -80 to +150 °C and a substance mixing ratio range of less than 1 ppt (pmol mol-1) to more than 500 ppt in preconcentrated sample volumes of 0.1 to 10 L of ambient air is covered, depending on the application and its analytical demands. We present the instrumental design of the preconcentration unit and demonstrate capabilities and performance through the examination of analyte breakthrough during adsorption, repeatability of desorption and analyte residues in blank tests. Examples of application are taken from the analysis of flask samples collected at Mace Head Atmospheric Research Station in Ireland using our laboratory GC-MS instruments and by data obtained during a research flight with our in situ aircraft instrument GhOST-MS (Gas chromatograph for the Observation of Tracers - coupled with a Mass Spectrometer).
NASA Astrophysics Data System (ADS)
Mendonça Costa, Lucimara; Ribeiro, Emerson Schwingel; Segatelli, Mariana Gava; do Nascimento, Danielle Raphael; de Oliveira, Fernanda Midori; Tarley, César Ricardo Teixeira
2011-05-01
The present study describes the adsorption characteristic of Cd(II) onto Nb 2O 5/Al 2O 3 mixed oxide dispersed on silica matrix. The characterization of the adsorbent has been carried out by infrared spectroscopy (IR), scanning electronic microscopy (SEM), energy dispersive spectroscopy (EDS), energy dispersive X-ray fluorescence analysis (EDXRF) and specific surface area ( SBET). From batch experiments, adsorption kinetic of Cd(II) was described by a pseudo-second-order kinetic model. The Langmuir linear isotherm fitted to the experimental adsorption isotherm very well, and the maximum adsorption capacity was found to be 17.88 mg g -1. Using the effective material, a method for Cd(II) preconcentration at trace level was developed. The method was based on on-line adsorption of Cd(II) onto SiO 2/Al 2O 3/Nb 2O 5 at pH 8.64, in which the quantitative desorption occurs with 1.0 mol L -1 hydrochloric acid towards FAAS detector. The experimental parameters related to the system were studied by means of multivariate analysis, using 2 4 full factorial design and Doehlert matrix. The effect of SO 42-, Cu 2+, Zn 2+ and Ni 2+ foreign ions showed no interference at 1:100 analyte:interferent proportion. Under the most favorable experimental conditions, the preconcentration system provided a preconcentration factor of 18.4 times, consumption index of 1.08 mL, sample throughput of 14 h -1, concentration efficiency of 4.35 min -1, linear range from 5.0 up to 35.0 μg L -1 and limits of detection and quantification of 0.19 and 0.65 μg L -1 respectively. The feasibility of the proposed method for Cd(II) determination was assessed by analysis of water samples, cigarette sample and certified reference materials TORT-2 (Lobster hepatopancreas) and DOLT-4 (Dogfish liver).
Corazza, Marcela Zanetti; Somera, Bruna Fabrin; Segatelli, Mariana Gava; Tarley, Cesar Ricardo Teixeira
2012-12-01
In the present study, the performance of multi-walled carbon nanotubes (MWCNTs) grafted with 3-mercaptopropyltrimethoxysilane (3-MPTMS), used as a solid phase extractor for Cd(2+) preconcentration in a flow injection system coupled to flame atomic absorption spectrometry (FAAS), was evaluated. The procedure involved the preconcentration of 20.0 mL of Cd(2+) solution at pH 7.5 (0.1 mol L(-1) buffer phosphate) through 70 mg of 3-MPTMS-grafted MWCNTs packed into a minicolumn at 6.0 mL min(-1). The elution step was carried out with 1.0 mol L(-1) HCl. Fourier transform infrared (FTIR) spectroscopy, scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) were used to estimate the extent of the MWCNT chemical modification. The 3-MPTMS-grafted MWCNTs provided a 1.68 times improvement in the sensitivity of the Cd(2+) FAAS determination compared to the unsilanized oxidized MWCNTs. The following parameters were obtained: preconcentration factor of 31.5, consumptive index of 0.635 mL, sample throughput of 14 h(-1), and concentration efficiency of 9.46 min(-1). The analytical curve was constructed in the range of 1.0-60.0 μg L(-1) (r=0.9988), and the detection and quantification limits were found to be 0.15 μg L(-1) and 0.62 μg L(-1), respectively. Different types of water samples and cigarette sample were successfully analyzed, and the results were compared using electrothermal atomic absorption spectrometry (ETAAS) as reference technique. In addition, the accuracy of proposed method was also checked by analysis of certified reference material NIST SRM 1573a (tomato leaves) and standard reference material NIST SRM 1643e (trace elements in natural waters). Copyright © 2012 Elsevier B.V. All rights reserved.
Filik, Hayati; Sener, Izzet; Cekiç, Sema Demirci; Kiliç, Emine; Apak, Reşat
2006-06-01
In the present paper, conventional spectrophotometry in conjunction with cloud point extraction-preconcentration were investigated as alternative methods for paracetamol (PCT) assay in urine samples. Cloud point extraction (CPE) was employed for the preconcentration of p-aminophenol (PAP) prior to spectrophotometric determination using the non-ionic surfactant Triton X-114 (TX-114) as an extractant. The developed methods were based on acidic hydrolysis of PCT to PAP, which reacted at room temperature with 25,26,27,28-tetrahydroxycalix[4]arene (CAL4) in the presence of an oxidant (KIO(4)) to form an blue colored product. The PAP-CAL4 blue dye formed was subsequently entrapped in the surfactant micelles of Triton X-114. Cloud point phase separation with the aid of Triton X-114 induced by addition of Na(2)SO(4) solution was performed at room temperature as an advantage over other CPE assays requiring elevated temperatures. The 580 nm-absorbance maximum of the formed product was shifted bathochromically to 590 nm with CPE. The working range of 1.5-12 microg ml(-1) achieved by conventional spectrophotometry was reduced down to 0.14-1.5 microg ml(-1) with cloud point extraction, which was lower than those of most literature flow-through assays that also suffer from nonspecific absorption in the UV region. By preconcentrating 10 ml sample solution, a detection limit as low as 40.0 ng ml(-1) was obtained after a single-step extraction, achieving a preconcentration factor of 10. The stoichiometric composition of the dye was found to be 1 : 4 (PAP : CAL4). The impact of a number of parameters such as concentrations of CAL4, KIO(4), Triton X-100 (TX-100), and TX-114, extraction temperature, time periods for incubation and centrifugation, and sample volume were investigated in detail. The determination of PAP in the presence of paracetamol in micellar systems under these conditions is limited. The established procedures were successfully adopted for the determination of PCT in urine samples. Since the drug is rapidly absorbed and excreted largely in urine and its high doses have been associated with lethal hepatic necrosis and renal failure, development of a rapid, sensitive and selective assay of PCT is of vital importance for fast urinary screening and antidote administration before applying more sophisticated, but costly and laborious hyphenated instrumental techniques of HPLC-SPE-NMR-MS.
Nucléation, ascension et éclatement d'une bulle de champagne
NASA Astrophysics Data System (ADS)
Liger-Belair, G.
2006-03-01
People have long been fascinated by bubbles and foams dynamics, and since the pioneering work of Leonardo da Vinci in the early 16th century, this subject has generated a huge bibliography. However, only quite recently, much interest was devoted to bubbles in Champagne wines and carbonated beverages. Since the time of the benedictine monk dom Pierre Perignon (1638-1715), champagne is the wine of celebration. This fame is largely linked to the elegance of its effervescence and foaming properties. In this book, the latest results about the chemical physics behind the bubbling properties of Champagne and sparkling wines are collected and fully illustrated. The first chapter is devoted to the history of champagne and to a presentation of the tools of the physical chemistry of interfaces needed for a whole comprehension of the book. Then, the three main steps of a fleeting champagne bubble's life are presented in chronological order, that is, the bubble nucleation on the glass wall (Chap.2), the bubble ascent and growth through the liquid matrix (Chap.3), and the bursting of bubbles at the liquid surface (Chap.4), which constitutes the most intriguing, functional, and visually appealing step. L'objectif général de ce travail consacré à l'étude des processus physicochimiques liés à l'effervescence des vins de Champagne était de décortiquer les différentes étapes de la vie d'une bulle de champagne en conditions réelles de consommation, dans une flûte. Nous résumons ci-après les principaux résultats obtenus pour chacune des étapes de la vie de la bulle, depuis sa naissance sur les parois d'une flûte, jusqu'à son éclatement en surface. Nucléation À l'aide d'une caméra rapide munie d'un objectif de microscope, nous avons pu mettre à mal une idée largement répandue. Ce ne sont pas les anfractuosités de la surface du verre ou de la flûte qui sont responsable de la nucléation hétérogène des bulles, mais des particules adsorbées sur les parois du verre ou de la flûte. Dans la majorité des cas, il s'agit de fibres de cellulose creuses dont les propriétés géométriques permettent le piégeage d'une poche d'air en leur sein au moment du versement. Un modèle de piégeage a été construit et met en avant le rôle fondamental joué par la vitesse du versement. Plus cette vitesse augmente, plus on augmente la probabilité de piéger des poches d'air au sein de ces fibres, provoquant ainsi une effervescence plus importante. La dynamique de production des bulles a également été filmée in situ à l'aide de la caméra, puis modélisée en utilisant les équations de la diffusion adaptées à la géométrie de notre fibre supposée approximativement cylindrique. Nous avons montré que le temps caractéristique de production d'une bulle par la fibre est largement gouverné par la croissance de cette petite poche de gaz par diffusion du CO{2} dissous vers la poche. Nous avons démontré que la convection du liquide joue un rôle essentiel lors du transfert de masse du CO{2} dissous vers la poche. En effet, un modèle purement diffusif ne permet pas du tout de reproduire la dynamique de croissance expérimentale de ces poches de gaz piégées au cœur des fibres. Nous avons également pu mettre en évidence des changements spectaculaires dans la dynamique de bullage de certains sites de nucléation suivis au cours du temps pendant le processus de dégazage. Ces observations font de la fibre de cellulose immergée dans le champagne le plus petit système de bullage non-linéaire observé à ce jour. Dynamique ascensionnelle Pour mesurer la vitesse d'une bulle tout au long de son trajet vers la surface libre du champagne, nous avons tiré profit de la production répétitive de bulles au niveau des sites de nucléation. Par la mise en place d'un dispositif expérimental simple qui associe une lumière stroboscopique et un appareil photographique muni de bagues macros, nous avons pu accéder à l'observation fine des trains de bulles ainsi qu'à la détermination de la vitesse ascensionnelle des bulles. Les mesures expérimentales du rayon et de la vitesse d'une bulle nous ont permis de déterminer le coefficient de traînée d'une bulle montante qui constitue une mesure indirecte de son état de surface en termes de mobilité interfaciale. Ces mesures nous ont montré que l'interface d'une bulle de champagne conserve une grande mobilité interfaciale pendant sa phase ascensionnelle, à la différence des bulles de taille fixe qui montent dans une solution de macromolécules tensioactives. C'est la faible dilution du champagne en macromolécules tensioactives et le grossissement continu des bulles pendant l'ascension qui assurent aux bulles une faible contamination de leur interface. Pour comparaison, nous avons réalisé le même type de mesures sur des bulles de bière. Le contenu en macromolécules tensioactives étant beaucoup plus important dans une bière, l'effet de dilution du matériel tensioactif à la surface des bulles lié à l'accroissement de la surface des bulles ne compense plus l'adsorption massive des tensioactifs à la surface des bulles. Contrairement aux bulles du champagne, les bulles de bière adoptent vite un comportement de type sphère rigide. Nous avons également discuté l'influence relative de certains paramètres sur la taille des bulles lorsqu'elles parviennent en surface. Il a notamment été montré que le rôle théorique joué par la température du champagne sur la taille des bulles est quasiment négligeable. Pour finir, nous avons proposé d'essayer de faire du train de bulles une sorte d'empreinte digitale du liquide effervescent dans lequel il évolue en analysant la dynamique ascensionnelle des bulles via la mesure de leur coefficient de frottement. Nous avons pu différencier à ce jour par cette méthode trois grandes familles de boissons gazeuses : les vins effervescents au sens large (champagne compris), les bières et les eaux gazeuses. Éclatement En utilisant les techniques classiques de la macrophotographie, nous avons obtenu des instantanés de la situation qui suit immédiatement la rupture du mince film liquide qui constitue la partie émergée d'une bulle isolée en surface. Nous avons ainsi pu mettre en évidence l'existence des jets de liquide engendrés par les éclatements de bulle, et leur rupture en gouttelettes suite au développement très rapide de l'instabilité de Rayleigh-Plateau. En faisant un parallèle légitime entre le pétillement des bulles à la surface du champagne et le “pétillement de l'océan”, nous avons émis l'idée que les gouttelettes de jet étaient beaucoup plus concentrées en matériel tensioactif (et potentiellement aromatique) que le cœur de phase du liquide. Il semble donc que l'éclatement de bulles joue un rôle essentiel dans l'effet exhausteur d'arômes au cours de la dégustation d'un champagne. Pendant les quelques secondes qui suivent le versement du champagne dans la flûte, nous avons également réalisé des clichés macrophotographiques et des films à haute vitesse d'éclatements de bulles en monocouche (ou radeau de bulles). Les premiers résultats de ces observations font apparaître des déformations spectaculaires dans le film liquide des bulles premières voisines littéralement aspirées par succion capillaire dans la cavité laissée vacante par la bulle centrale en train d'éclater. Ces premières images suggèrent des contraintes, dans le mince film des bulles déformées, très supérieures à celles qui existent dans le sillage d'une bulle isolée qui éclate. Nous avons également pu mettre en évidence des différences structurales entre les jets de liquide qui suivent l'éclatement des bulles isolées et celles qui éclatent dans un radeau de bulles.
Belostotsky, Inessa; Gridin, Vladimir V; Schechter, Israel; Yarnitzky, Chaim N
2003-02-01
An improved analytical method for airborne lead traces is reported. It is based on using a Venturi scrubber sampling device for simultaneous thin-film stripping and droplet entrapment of aerosol influxes. At least threefold enhancement of the lead-trace pre-concentration is achieved. The sampled traces are analyzed by square-wave anodic stripping voltammetry. The method was tested by a series of pilot experiments. These were performed using contaminant-controlled air intakes. Reproducible calibration plots were obtained. The data were validated by traditional analysis using filter sampling. LODs are comparable with the conventional techniques. The method was successfully applied to on-line and in situ environmental monitoring of lead.
Human portable preconcentrator system
Linker, Kevin L.; Brusseau, Charles A.; Hannum, David W.; Puissant, James G.; Varley, Nathan R.
2003-08-12
A preconcentrator system and apparatus suited to human portable use wherein sample potentially containing a target chemical substance is drawn into a chamber and through a pervious screen. The screen is adapted to capture target chemicals and then, upon heating, to release those chemicals into the chamber. Chemicals captured and then released in this fashion are then carried to a portable chemical detection device such as a portable ion mobility spectrometer. In the preferred embodiment, the means for drawing sample into the chamber comprises a reversible fan which, when operated in reverse direction, creates a backpressure that facilitates evolution of captured target chemicals into the chamber when the screen is heated. The screen can be positioned directly in front of the detector prior to heating to improve detection capability.
Micromechanisms of intergranular brittle ftacture in intermetallic compounds
NASA Astrophysics Data System (ADS)
Vitek, V.
1991-06-01
Grain boundaries in intermetallic compounds such as Ni3A1 are inherently brittle. The reason is usually sought in grain boundary cohesion but in metals even brittle fracture is accompanied by some local plasticity and thus not only cohesion but also dislocation mobility in the boundary region need to be studied. We first discuss here the role of an irreversible shear deformation at the crack tip during microcrack propagation assuming that these two processes are concomitant. It is shown that a pre-existing crack cannot propagate in a brittle manner once the dislocation emission occurs. However, if a microcrack nucleates during loading it can propagate concurrently with the development of the irreversible shear deformation at the crack tip. The latter is then the major energy dissipating process. In the second part of this paper we present results of atomistic studies of grain boundaries in Ni3A1 and CU3Au which suggest that substantial structural differences exist between strongly and weakly ordered L12 alloys. We discuss then the consequence of these differences for intergranular brittleness in the framework of the above model for microcrack propagation. On this basis we propose an explanation for the intrinsic intergranular brittleness in some L12 alloys and relate it directly to the strength of ordering. Les joints de grains dans les composés intermétalliques de type Ni3AI sont de nature fragile. L'origine de cette fragilité est habituellement dans la cohésion des joints de grains. Dans les métaux, cependant, même la rupture fragile est accompagnée d'une certaine déformation plastique locale, de telle sorte que non seulement la cohésion mais aussi la mobilité des dislocations près des joints doit être étudiée. Nous discutons d'abord le rôle d'une déformation en cisaillement irréversible en tête de fissure pendant la propagation de cette fissure, en supposant que les deux processus sont concomitants. Nous montrons qu'une fissure préexistante ne peut pas se propager de manière fragile, une fois que l'émission de dislocations se produit. Cependant, si une microfissure apparaît pendant le changement, elle peut se développer en concurrence avec le développement d'un cisaillement irréversible en tête de fissure. Ce demier est alors le principal mécanisme dissipatif d'énergie. Dans la deuxième partie de cet article, nous présentons des résultats d'études atomiques de joints de grain dans Ni3AI et CU3Au, suggérant qu'il existe des différences de structure substancielles entre les alliages L12 fortement et faiblement ordonnés. Nous discutons ensuite la conséquence de ces différences pour la fragilité intergranulaire, à l'aide du modèle ci-dessus pour la propagation des microfissures. Sur cette base, nous proposons une explication pour la fragilité intergranulaire intrinsèque de quelques alliages L12, et nous la relions directement au degré d'ordre.
Kazemi, Elahe; Dadfarnia, Shayessteh; Haji Shabani, Ali Mohammad
2015-08-15
A selective, simple and rapid dispersive solid phase microextraction was developed using magnetic graphene oxide (MGO) as an efficient sorbent for the separation and preconcentration of gold ions. The MGO was synthesized by means of the simple one step chemical coprecipitation method, characterized by X-ray diffraction (XRD), Fourier transform infrared (FT-IR) spectroscopy and scanning electron microscopy (SEM). Gold ions retained by the sorbent were eluted using 0.5mol L(-)(1) thiourea in 0.1mol L(-1) HCl solution and determined by the flow injection flame atomic absorption spectrometry (FI-FAAS). The factors affecting the separation and preconcentration of gold were investigated and optimized. Under the optimized conditions, the method exhibited a linear dynamic range of 0.02-100.0µg L(-)(1) with a detection limit of 4ng L(-1) and an enrichment factor of 500. The relative standard deviations of 3.2% and 4.7% (n=6) were obtained at 20µg L(-1) level of gold ions for the intra and the inter day analysis, respectively. The method was successfully applied to the determination of gold ions in water and waste water samples as well as a certified reference material (CCU-1b, copper flotation concentrate). Copyright © 2015 Elsevier B.V. All rights reserved.
Abou Mrad, Ninette; Duvernay, Fabrice; Theulé, Patrice; Chiavassa, Thierry; Danger, Grégoire
2014-08-19
This contribution presents an original analytical system for studying volatile organic compounds (VOC) coming from the heating and/or irradiation of interstellar/cometary ice analogues (VAHIIA system) through laboratory experiments. The VAHIIA system brings solutions to three analytical constraints regarding chromatography analysis: the low desorption kinetics of VOC (many hours) in the vacuum chamber during laboratory experiments, the low pressure under which they sublime (10(-9) mbar), and the presence of water in ice analogues. The VAHIIA system which we developed, calibrated, and optimized is composed of two units. The first is a preconcentration unit providing the VOC recovery. This unit is based on a cryogenic trapping which allows VOC preconcentration and provides an adequate pressure allowing their subsequent transfer to an injection unit. The latter is a gaseous injection unit allowing the direct injection into the GC-MS of the VOC previously transferred from the preconcentration unit. The feasibility of the online transfer through this interface is demonstrated. Nanomoles of VOC can be detected with the VAHIIA system, and the variability in replicate measurements is lower than 13%. The advantages of the GC-MS in comparison to infrared spectroscopy are pointed out, the GC-MS allowing an unambiguous identification of compounds coming from complex mixtures. Beyond the application to astrophysical subjects, these analytical developments can be used for all systems requiring vacuum/cryogenic environments.
Lyotropic liquid crystal preconcentrates for the treatment of periodontal disease.
Fehér, A; Urbán, E; Eros, I; Szabó-Révész, P; Csányi, E
2008-06-24
The aim of our study was to develop water-free lyotropic liquid crystalline preconcentrates, which consist of oils and surfactants with good physiological tolerance and spontaneously form lyotropic liquid crystalline phase in aqueous environment. In this way these preconcentrates having low viscosity can be injected into the periodontal pocket, where they are transformed into highly viscous liquid crystalline phase, so that the preparation is prevented from flowing out of the pocket due to its great viscosity, while drug release is controlled by the liquid crystalline texture. In order to follow the structure alteration upon water absorption polarization microscopical and rheological examinations were performed. The water absorption mechanism of the samples was examined by the Enslin-method. Metronidazole-benzoate was used as active agent the release of which was characterized via in vitro investigations performed by means of modified Kirby-Bauer disk diffusion method. On the grounds of the results it can be stated that the 4:1 mixture of the investigated surfactants (Cremophor EL, Cremophor RH40) and oil (Miglyol 810) formed lyotopic liquid crystalline phases upon water addition. Polarization microscopic examinations showed that samples with 10-40% water content possessed anisotropic properties. On the basis of water absorption, rheological and drug release studies it can be concluded that the amount of absorbed water and stiffness of lyotropic structure influenced by the chemical entity of the surfactant exerted major effect on the drug release.
Strutwolf, Jörg; Arrigan, Damien W M
2010-10-01
Micropore membranes have been used to form arrays of microinterfaces between immiscible electrolyte solutions (µITIES) as a basis for the sensing of non-redox-active ions. Implementation of stripping voltammetry as a sensing method at these arrays of µITIES was applied recently to detect drugs and biomolecules at low concentrations. The present study uses computational simulation to investigate the optimum conditions for stripping voltammetric sensing at the µITIES array. In this scenario, the diffusion of ions in both the aqueous and the organic phases contributes to the sensing response. The influence of the preconcentration time, the micropore aspect ratio, the location of the microinterface within the pore, the ratio of the diffusion coefficients of the analyte ion in the organic and aqueous phases, and the pore wall angle were investigated. The simulations reveal that the accessibility of the microinterfaces during the preconcentration period should not be hampered by a recessed interface and that diffusional transport in the phase where the analyte ions are preconcentrated should be minimized. This will ensure that the ions are accumulated within the micropores close to the interface and thus be readily available for back transfer during the stripping process. On the basis of the results, an optimal combination of the examined parameters is proposed, which together improve the stripping voltammetric signal and provide an improvement in the detection limit.
Patra, Santanu; Roy, Ekta; Madhuri, Rashmi; Sharma, Prashant K
2015-05-19
In this study, nanocomposite of graphene oxide and silane modified magnetic nanoparticles (silane@Fe3O4) were synthesized in a form of dendritic structure. For this, silane@Fe3O4 nanoparticle gets sandwiched between two layers of graphene oxide by chemical synthesis route. The synthesized dendritic structure was used as a monomer for synthesis of europium ion imprinted polymer. The synthesis of imprinted polymer was contemplated onto the surface of the vinyl group modified silica fiber by activated generated free radical atom-transfer radical polymerization, that is, AGET-ATRP technique. The synthesized dendritic monomer was characterized by XRD, FT-IR, VSM, FE-SEM, and TEM analyses. The imprinted polymer modified silica fiber was first validated in the aqueous and blood samples for successful extraction and detection of europium ion with limit of detection = 0.050 pg mL(-1) (signal/noise = 3). The imprinted polymer modified silica fiber was also used for preconcentration and separation of europium metal ion from various soil samples of coal mine areas. However, the same silica fiber was also used for wastewater treatment and shows 100% performance for europium removal. The findings herein suggested that dendritic nanocomposite could be potentially used as a highly effective material for the enrichment and preconcentration of europium or other trivalent lanthanides/actinides in nuclear waste management.
Yamini, Yadollah; Ghambarian, Mahnaz; Khalili-Zanjani, Mohammad Reza; Faraji, Mohammad; Shariati, Shahab
2009-09-01
Two approaches based on solidification of floating drop microextraction (SFDME) and homogenous liquid-liquid microextraction (HLLE) were compared for the extraction and preconcentration of di-(2-ethylhexyl) phthalate (DEHP) and di-(2-ethylhexyl) adipate (DEHA) from the mineral water samples. In SFDME, a floated drop of the mixture of acetophenone/1-undecanol (1:8) was exposed on the surface of the aqueous solution and extraction was permitted to occur. In HLLE, a homogenous ternary solvent system was used by water/methanol/chloroform and the phase separation phenomenon occurred by salt addition. Under the optimal conditions, the LODs for the two target plasticizers (DEHA and DEHP), obtained by SFDME-GC-FID and HLLE-GC-FID, were ranged from 0.03 to 0.01 microg/L and 0.02 to 0.01 microg/L, respectively. HLLE provided higher preconcentration factors (472.5- and 551.2-fold) within the shorter extraction time as well as better RSDs (4.5-6.9%). While, in SFDME, high preconcentration factors in the range of 162-198 and good RSDs in the range of 5.2-9.6% were obtained. Both methods were applied for the analysis of two plasticizers in different water samples and two target plasticizers were found in the bottled mineral water after the expiring time and the boiling water was exposed to a polyethylene vial.
Prado, Alexandre G S; Pescara, Igor C; Evangelista, Sheila M; Holanda, Matheus S; Andrade, Romulo D; Suarez, Paulo A Z; Zara, Luiz F
2011-05-15
Biodiesel and diesel-like have been obtained from soybean oil by transesterification and thermal cracking process, respectively. These biofuels were characterized as according to ANP standards by using specific ASTM methods. Ethanol, gasoline, and diesel were purchased from a gas station. Deacetylation degree of chitosan was determined by three distinct methods (conductimetry, FTIR and NMR), and the average degree was 78.95%. The chitosan microspheres were prepared from chitosan by split-coating and these spheres were crosslinked using glutaraldehyde. The surface area of microspheres was determined by BET method, and the surface area of crosslinked microspheres was 9.2m(2)g(-1). The adsorption isotherms of cooper, nickel and zinc on microspheres of chitosan were determined in petroleum derivatives (gasoline and diesel oil), as well as in biofuels (alcohol, biodiesel and diesel-like). The adsorption order in all fuels was: Cu>Ni>Zn. The elution tests presented the following preconcentration degrees: >4.5 to ethanol, >4.4 to gasoline, >4.0 to diesel, >3.8 to biodiesel and >3.6 to diesel-like. The application of chitosan microspheres in the metal ions preconcentration showed the potential of this biopolymer to enrich fuel sample in order to be analyzed by flame atomic absorption spectrometry. Copyright © 2011 Elsevier B.V. All rights reserved.
Kachangoon, Rawikan; Vichapong, Jitlada; Burakham, Rodjana; Santaladchaiyakit, Yanawath; Srijaranai, Supalax
2018-05-12
An effective pre-concentration method, namely amended-cloud point extraction (CPE), has been developed for the extraction and pre-concentration of neonicotinoid insecticide residues. The studied analytes including clothianidin, imidacloprid, acetamiprid, thiamethoxam and thiacloprid were chosen as a model compound. The amended-CPE procedure included two cloud point processes. Triton™ X-114 was used to extract neonicotinoid residues into the surfactant-rich phase and then the analytes were transferred into an alkaline solution with the help of ultrasound energy. The extracts were then analyzed by high-performance liquid chromatography (HPLC) coupled with a monolithic column. Several factors influencing the extraction efficiency were studied such as kind and concentration of surfactant, type and content of salts, kind and concentration of back extraction agent, and incubation temperature and time. Enrichment factors (EFs) were found in the range of 20⁻333 folds. The limits of detection of the studied neonicotinoids were in the range of 0.0003⁻0.002 µg mL −1 which are below the maximum residue limits (MRLs) established by the European Union (EU). Good repeatability was obtained with relative standard deviations lower than 1.92% and 4.54% for retention time ( t R ) and peak area, respectively. The developed extraction method was successfully applied for the analysis of water samples. No detectable residues of neonicotinoids in the studied samples were found.
Keramat, Akram; Zare-Dorabei, Rouholah
2017-09-01
In this work, the synthesis of the magnetic graphene oxide modified by 2-pyridinecarboxaldehyde thiosemicarbazone groups (Fe 3 O 4 @GO/2-PTSC) was utilized for preconcentration and determination of mercuric ions in a trace amount by inductively coupled plasma-optical emission spectrometry (ICP-OES). Characterization of the adsorbent was performed using various techniques, such as FT-IR, VSM, SEM and XRD analysis. Central composite design (CCD) under response surface methodology (RSM) was used for obtaining the most important parameters and probable interactions in variables. The variables such as adsorbent dosage, pH, desorption time, and eluent volume was optimized. These values were 8mg, 5.4min, 0.5mL (HCl, 0.1M), respectively. Sonication had an important role in shortening the adsorption time of Hg (II) ions by enhancing the dispersion of adsorbent in solution. Under the optimal conditions, the proposed method presented high enrichment factor of 193, an extraction percentage of 96.5, a detection limit of 0.0079µgL -1 and a relative standard deviation (RSD %) of 1.63%. Finally, the application of the synthesized material was evaluated for preconcentration and determination of mercuric ions from foods and environmental waters samples. Copyright © 2017 Elsevier B.V. All rights reserved.
Justification of rapid prototyping in the development cycle of thermoplastic-based lab-on-a-chip.
Preywisch, Regina; Ritzi-Lehnert, Marion; Drese, Klaus S; Röser, Tina
2011-11-01
During the developmental cycle of lab-on-a-chip devices, various microstructuring techniques are required. While in the designing and assay implementation phase direct structuring or so-called rapid-prototyping methods such as milling or laser ablation are applied, replication methods like hot embossing or injection moulding are favourable for large quantity manufacturing. This work investigated the applicability of rapid-prototyping techniques for thermoplastic chip development in general, and the reproducibility of performances in dependency of the structuring technique. A previously published chip for prenatal diagnosis that preconcentrates DNA via electrokinetic trapping and field-amplified-sample-stacking and afterwards separates it in CGE was chosen as a model. The impact of structuring, sealing, and the integration of membranes on the mobility of the EOF, DNA preconcentration, and DNA separation was studied. Structuring methods were found to significantly change the location where preconcentration of DNA occurs. However, effects on the mobility of the EOF and the separation quality of DNA were not observed. Exchange of the membrane has no effect on the chip performance, whereas the sealing method impairs the separation of DNA within the chip. The overall assay performance is not significantly influenced by different structuring methods; thus, the application of rapid-prototyping methods during a chip development cycle is well justified. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Krawczyk-Coda, Magdalena
2017-03-01
In this research, a simple, accurate, and inexpensive preconcentration procedure was developed for the determination of bismuth in water samples, using high-resolution continuum source graphite furnace atomic absorption spectrometry (HR CS GFAAS). During the preconcentration step, halloysite nanotubes (HNTs) were used as a solid sorbent in ultrasound-assisted dispersive micro solid-phase extraction (USA DMSPE). The influence of the pH of the sample solution, amount of HNTs, and extraction time, as well as of the main parameters of HR CS GFAAS, on absorbance was investigated. The limit of detection was 0.005 μg L- 1. The preconcentration factor achieved for bismuth was 32. The relative standard deviation (RSD) was 4%. The accuracy of this method was validated by analyses of NIST SRM 1643e (Trace elements in water) and TMDA-54.5 (A high level fortified sample for trace elements) certified reference materials. The measured bismuth contents in these certified reference materials were in satisfactory agreement with the certified values according to the t-test for a 95% confidence level. The proposed method has been successfully applied to the determination of bismuth in five different real water samples (seawater, lake water, river water, stream water and rain water).
Ensafi, Ali A; Ghaderi, Ali R
2007-09-05
An on-line flow system was used to develop a selective and efficient on-line sorbent extraction preconcentration system for cadmium. The method is based on adsorption of cadmium ions onto the activated carbon modified with methyl thymol blue. Then the adsorbed ions were washed using 0.5M HNO(3) and the eluent was used to determine the Cd(II) ions using flame atomic absorption spectrometry. The results obtained show that the modified activated carbon has the greatest adsorption capacity of 80 microg of Cd(II) per 1.0 g of the solid phase. The optimal pH value for the quantitative preconcentration was 9.0 and full desorption is achieved by using 0.5M HNO(3) solution. It is established that the solid phase can be used repeatedly without a considerable adsorption capacity loss. The detection limit was less than 1 ngmL(-1) Cd(II), with an enrichment factor of 1000. The calibration graph was linear in the range of 1-2000 ngmL(-1) Cd(II). The developed method has been applied to the determination of trace cadmium (II) in water samples and in the following reference materials: sewage sludge (CRM144R), and sea water (CASS.4) with satisfactory results. The accuracy was assessed through recovery experiments.
Gao, Ru; Hu, Zheng; Chang, Xijun; He, Qun; Zhang, Lijun; Tu, Zhifeng; Shi, Jianping
2009-12-15
A new sorbent 1-acylthiosemicarbazide-modified activated carbon (AC-ATSC) was prepared as a solid-phase extractant and applied for removing of trace Cu(II), Hg(II) and Pb(II) prior to their determination by inductively coupled plasma optical emission spectrometry (ICP-OES). The separation/preconcentration conditions of analytes were investigated, including effects of pH, the shaking time, the sample flow rate and volume, the elution condition and the interfering ions. At pH 3, the maximum static adsorption capacity of Cu(II), Hg(II) and Pb(II) onto the AC-ATSC were 78.20, 67.80 and 48.56 mg g(-1), respectively. The adsorbed metal ions were quantitatively eluted by 3.0 mL of 2% CS(NH2)2 and 2.0 mol L(-1) HCl solution. Common coexisting ions did not interfere with the separation. According to the definition of IUPAC, the detection limits (3sigma) of this method for Cu(II), Hg(II) and Pb(II) were 0.20, 0.12 and 0.45 ng mL(-1), respectively. The relative standard deviation under optimum conditions is less than 4.0% (n=8). The prepared sorbent was applied for the preconcentration of trace Cu(II), Hg(II) and Pb(II) in certified and water samples with satisfactory results.
Sperling, M; Yin, X; Welz, B
1992-03-01
A rapid, sensitive and selective method for the differential determination of CrIII and CrVI in natural waters is described. Chromium(vi) can be determined directly by flow injection on-line sorbent extraction preconcentration coupled with electrothermal atomic absorption spectrometry using sodium diethyldithiocarbamate as the complexing agent and C18 bonded silica reversed-phase sorbent as the column material. Total Cr can be determined after oxidation of CrIII to CrVI by potassium peroxydisulfate. Chromium(III) can be calculated by difference. The optimum conditions for sorbent extraction of CrVI and oxidation of CrIII to CrVI are evaluated. A 12-fold enhancement in sensitivity compared with direct introduction of 40 microliters samples was achieved after preconcentration for 60 s, giving detection limits of 16 ng l-1 for CrVI and 18 ng l-1 for total Cr (based on 3 sigma). Results obtained for sea-water and river water reference materials were all within the certified range for total Cr with a precision of better than 10% relative standard deviation in the range 100-200 ng l-1. The selectivity of the determination of CrVI was evaluated by analysing spiked reference materials in the presence of CrIII, resulting in quantitative recovery of CrVI.
Luque-García, J L; Luque de Castro, M D
2002-08-01
A continuous ultrasound-assisted extractor was coupled to a photometric detector in order to obtain a fully automated approach for the determination of CrVI in soil. The use of a flow injection (FI) manifold as interface between the extractor and the photometric detector allowed the monitoring of CrVI after extraction in a continuous manner. The coloured complex formed between 1,5-diphenylcarbazide (DPC) and CrVI was used as recommended in EPA method 7196A because it is one of the most sensitive and selective reactions for CrVI determination. A preconcentration minicolumn packed with a strong anion-exchange resin was placed between the extractor and the detector, providing a more sensitive method. The linear dynamic ranges were 1-10 and 0.25-7.5 mg l-1 for the methods without (method A) and with preconcentration (method B), respectively. The limits of detection were 4.52 ng for method A and 1.23 ng for method B. Both methods were applied to a natural contaminated soil and the results obtained agreed well with those obtained by the reference EPA method 3060A. The influence of different amounts of CrIII in the samples was also studied and the results showed that the proposed methods did not disturb the original species distribution.
An on-line pre-concentration system for determination of cadmium in drinking water using FAAS.
dos Santos, Walter N L; Costa, Jorge L O; Araujo, Rennan G O; de Jesus, Djane S; Costa, Antônio C S
2006-10-11
In the present paper, a minicolumn of polyurethane foam loaded with 4-(2-pyridylazo)-resorcinol (PAR) is proposed as pre-concentration system for cadmium determination in drinking water samples by flame atomic absorption spectrometry. The optimization step was performed using two-level full factorial design and Doehlert matrix, involving the variables: sampling flow rate, elution concentration, buffer concentration and pH. Using the established experimental conditions in the optimization step of: pH 8.2, sampling flow rate 8.5 mL min(-1), buffer concentration 0.05 mol L(-1) and elution concentration of 1.0 mol L(-1), this system allows the determination of cadmium with detection limit (LD) (3sigma/S) of 20.0 ng L(-1) and quantification limit (LQ) (10sigma/S) of 64 ng L(-1), precision expressed as relative standard deviation (R.S.D.) of 5.0 and 4.7% for cadmium concentration of 5.0 and 40.0 microg L(-1), respectively, and a pre-concentration factor of 158 for a sample volume of 20.0 mL. The accuracy was confirmed by cadmium determination in the standard reference material, NIST SRM 1643d trace elements in natural water. This procedure was applied for cadmium determination in drinking water samples collected from Salvador City, Bahia, Brazil. For five samples analyzed, the achieved concentrations varied from 0.31 to 0.86 microg L(-1).
Microchip integrating magnetic nanoparticles for allergy diagnosis.
Teste, Bruno; Malloggi, Florent; Siaugue, Jean-Michel; Varenne, Anne; Kanoufi, Frederic; Descroix, Stéphanie
2011-12-21
We report on the development of a simple and easy to use microchip dedicated to allergy diagnosis. This microchip combines both the advantages of homogeneous immunoassays i.e. species diffusion and heterogeneous immunoassays i.e. easy separation and preconcentration steps. In vitro allergy diagnosis is based on specific Immunoglobulin E (IgE) quantitation, in that way we have developed and integrated magnetic core-shell nanoparticles (MCSNPs) as an IgE capture nanoplatform in a microdevice taking benefit from both their magnetic and colloidal properties. Integrating such immunosupport allows to perform the target analyte (IgE) capture in the colloidal phase thus increasing the analyte capture kinetics since both immunological partners are diffusing during the immune reaction. This colloidal approach improves 1000 times the analyte capture kinetics compared to conventional methods. Moreover, based on the MCSNPs' magnetic properties and on the magnetic chamber we have previously developed the MCSNPs and therefore the target can be confined and preconcentrated within the microdevice prior to the detection step. The MCSNPs preconcentration factor achieved was about 35,000 and allows to reach high sensitivity thus avoiding catalytic amplification during the detection step. The developed microchip offers many advantages: the analytical procedure was fully integrated on-chip, analyses were performed in short assay time (20 min), the sample and reagents consumption was reduced to few microlitres (5 μL) while a low limit of detection can be achieved (about 1 ng mL(-1)).
Breitkreitz, Márcia C; Sabin, Guilherme P; Polla, Griselda; Poppi, Ronei J
2013-01-25
A methodology based on Raman image spectroscopy and chemometrics for homogeneity evaluation of formulations containing atorvastatin calcium in Gelucire(®) 44/14 is presented. In the first part of the work, formulations with high amounts of Gelucire(®) 44/14 (80%) and solvents of different polarities (diethylene glycol monoethyl ether, propyleneglycol, propylene glycol monocaprylate and glyceryl mono/dicaprylate/caprate) were prepared for miscibility screening evaluation by classical least squares (CLS). It was observed that Gelucire(®) 44/14 presented higher affinity for the lipophilic solvents glyceryl mono/dicaprylate/caprate and propylene glycol monocaprylate, whose samples were observed to be homogeneous, and lower affinity for the hydrophilic solvents diethylene glycol monoethyl ether and propyleneglycol, whose samples were heterogeneous. In the second part of the work, the ratio of glyceryl mono/dicaprylate/caprate and Gelucire(®) 44/14 was determined based on studies in water and allowed the selection of the proportions of these two excipients in the preconcentrate that provided supersaturation of atorvastatin upon dilution. The preconcentrate was then evaluated for homogeneity by partial least squares (PLS) and an excellent miscibility was observed in this proportion as well. Therefore, it was possible to select a formulation that presented simultaneously homogeneous preconcentrate and solubility enhancement in water by Raman image spectroscopy and chemometrics. Copyright © 2012 Elsevier B.V. All rights reserved.
Bianchin, Joyce Nunes; Martendal, Edmar; Mior, Renata; Alves, Vanessa Nunes; Araújo, Cleide Sandra Tavares; Coelho, Nívia Maria Melo; Carasek, Eduardo
2009-04-30
In this study a method for the determination of cadmium in fuel alcohol using solid-phase extraction with a flow injection analysis system and detection by flame atomic absorption spectrometry was developed. The sorbent material used was a vermicompost commonly used as a garden fertilizer. The chemical and flow variables of the on-line preconcentration system were optimized by means of a full factorial design. The selected factors were: sorbent mass, sample pH, buffer concentration and sample flow rate. The optimum extraction conditions were obtained using sample pH in the range of 7.3-8.3 buffered with tris(hydroxymethyl)aminomethane at 50 mmol L(-1), a sample flow rate of 4.5 mL min(-1) and 160 mg of sorbent mass. With the optimized conditions, the preconcentration factor, limit of detection and sample throughput were estimated as 32 (for preconcentration of 10 mL sample), 1.7 microg L(-1) and 20 samples per hour, respectively. The analytical curve was linear from 5 up to at least 50 microg L(-1), with a correlation coefficient of 0.998 and a relative standard deviation of 2.4% (35 microg L(-1), n=7). The developed method was successfully applied to spiked fuel alcohol, and accuracy was assessed through recovery tests, with recovery ranging from 94% to 100%.
Analysis of isothiazolinones in environmental waters by gas chromatography-mass spectrometry.
Rafoth, Astrid; Gabriel, Sabine; Sacher, Frank; Brauch, Heinz-Jürgen
2007-09-14
This paper describes an analytical method for the determination of five biocides of isothiazolinone type (2-methyl-3-isothiazolinone (MI), 5-chloro-2-methyl-3-isothiazolinone (CMI), 1,2-benzisothiazolinone (BIT), 2-octyl-3-isothiazolinone (OI), 4,5-dichloro-2-octyl-3-isothiazolinone (DCOI)) in environmental waters. The method is based on pre-concentration of the analytes by solid-phase extraction onto a mixture of a polymeric material and RP-C18 material and subsequent determination by gas chromatography-mass spectrometry (GC-MS). One of the target compounds (BIT) is derivatised with diazomethane after pre-concentration to improve its chromatographic performance. The method was optimised with respect to pre-concentration conditions (liquid-liquid extraction versus solid-phase extraction, solid-phase material, elution solvent and volume) and extensively validated. Applying the method to surface waters, groundwaters, and drinking waters, limits of detection between 0.01 and 0.1 microg/l could be achieved and the repeatability was below 10% for all compounds except for MI. Additional investigations showed that the stability of the isothiazolinones in environmental waters is limited and sample storage at 4 degrees C is mandatory to preserve the target biocides. First investigations of influents and effluents of a wastewater treatment plant showed that conventional wastewater treatment exhibits a high efficiency for removal of the isothiazolinones. In river waters, the target isothiazolinones could not be detected.
Li, Shunbo; Li, Ming; Bougot-Robin, Kristelle; Cao, Wenbin; Yeung Yeung Chau, Irene; Li, Weihua; Wen, Weijia
2013-01-01
Integrating different steps on a chip for cell manipulations and sample preparation is of foremost importance to fully take advantage of microfluidic possibilities, and therefore make tests faster, cheaper and more accurate. We demonstrated particle manipulation in an integrated microfluidic device by applying hydrodynamic, electroosmotic (EO), electrophoretic (EP), and dielectrophoretic (DEP) forces. The process involves generation of fluid flow by pressure difference, particle trapping by DEP force, and particle redirect by EO and EP forces. Both DC and AC signals were applied, taking advantages of DC EP, EO and AC DEP for on-chip particle manipulation. Since different types of particles respond differently to these signals, variations of DC and AC signals are capable to handle complex and highly variable colloidal and biological samples. The proposed technique can operate in a high-throughput manner with thirteen independent channels in radial directions for enrichment and separation in microfluidic chip. We evaluated our approach by collecting Polystyrene particles, yeast cells, and E. coli bacteria, which respond differently to electric field gradient. Live and dead yeast cells were separated successfully, validating the capability of our device to separate highly similar cells. Our results showed that this technique could achieve fast pre-concentration of colloidal particles and cells and separation of cells depending on their vitality. Hydrodynamic, DC electrophoretic and DC electroosmotic forces were used together instead of syringe pump to achieve sufficient fluid flow and particle mobility for particle trapping and sorting. By eliminating bulky mechanical pumps, this new technique has wide applications for in situ detection and analysis. PMID:24404011
Li, Shunbo; Li, Ming; Bougot-Robin, Kristelle; Cao, Wenbin; Yeung Yeung Chau, Irene; Li, Weihua; Wen, Weijia
2013-01-01
Integrating different steps on a chip for cell manipulations and sample preparation is of foremost importance to fully take advantage of microfluidic possibilities, and therefore make tests faster, cheaper and more accurate. We demonstrated particle manipulation in an integrated microfluidic device by applying hydrodynamic, electroosmotic (EO), electrophoretic (EP), and dielectrophoretic (DEP) forces. The process involves generation of fluid flow by pressure difference, particle trapping by DEP force, and particle redirect by EO and EP forces. Both DC and AC signals were applied, taking advantages of DC EP, EO and AC DEP for on-chip particle manipulation. Since different types of particles respond differently to these signals, variations of DC and AC signals are capable to handle complex and highly variable colloidal and biological samples. The proposed technique can operate in a high-throughput manner with thirteen independent channels in radial directions for enrichment and separation in microfluidic chip. We evaluated our approach by collecting Polystyrene particles, yeast cells, and E. coli bacteria, which respond differently to electric field gradient. Live and dead yeast cells were separated successfully, validating the capability of our device to separate highly similar cells. Our results showed that this technique could achieve fast pre-concentration of colloidal particles and cells and separation of cells depending on their vitality. Hydrodynamic, DC electrophoretic and DC electroosmotic forces were used together instead of syringe pump to achieve sufficient fluid flow and particle mobility for particle trapping and sorting. By eliminating bulky mechanical pumps, this new technique has wide applications for in situ detection and analysis.
Development of a novel cell sorting method that samples population diversity in flow cytometry.
Osborne, Geoffrey W; Andersen, Stacey B; Battye, Francis L
2015-11-01
Flow cytometry based electrostatic cell sorting is an important tool in the separation of cell populations. Existing instruments can sort single cells into multi-well collection plates, and keep track of cell of origin and sorted well location. However currently single sorted cell results reflect the population distribution and fail to capture the population diversity. Software was designed that implements a novel sorting approach, "Slice and Dice Sorting," that links a graphical representation of a multi-well plate to logic that ensures that single cells are sampled and sorted from all areas defined by the sort region/s. Therefore the diversity of the total population is captured, and the more frequently occurring or rarer cell types are all sampled. The sorting approach was tested computationally, and using functional cell based assays. Computationally we demonstrate that conventional single cell sorting can sample as little as 50% of the population diversity dependant on the population distribution, and that Slice and Dice sorting samples much more of the variety present within a cell population. We then show by sorting single cells into wells using the Slice and Dice sorting method that there are cells sorted using this method that would be either rarely sorted, or not sorted at all using conventional single cell sorting approaches. The present study demonstrates a novel single cell sorting method that samples much more of the population diversity than current methods. It has implications in clonal selection, stem cell sorting, single cell sequencing and any areas where population heterogeneity is of importance. © 2015 International Society for Advancement of Cytometry.
Grote, I; Rosales, J; Baer, D M
1996-11-01
Three preschool children repeatedly did four kinds of sorts with a deck of stimulus cards: a difficult, untaught target sort and three other sorts considered analytic of self-instructing the target performance. The untaught target sort was to find in a deck of cards those matching what two sample cards had in common. Most preschool children must be taught to mediate this problem. The three other kinds of sorts taught skills involved in the target performance or its mediation. As correct self-instructive talk emerged in the target sorts, it was confirmed. The untaught target sorts were interspersed infrequently among the three alternating directly taught skill sorts, to see if accurate target sorts, and accurate self-instructive talk about the target sorts, would emerge as the three skill sorts were mastered. As all the sorts progressed, increasing accuracy was seen first in the skill sorts and then in the untaught target sorts. All three subjects showed subsequent generalization to new target sorts involving other stimulus sets. Correct spontaneous self-instructions about the target sorts increased from near zero at the beginning of the experiment to consistency at its end. Thus the three skill sorts appeared sufficient for the emergence of a self-instructed solution to the previously insoluble target performance.
Parallel sort with a ranged, partitioned key-value store in a high perfomance computing environment
Bent, John M.; Faibish, Sorin; Grider, Gary; Torres, Aaron; Poole, Stephen W.
2016-01-26
Improved sorting techniques are provided that perform a parallel sort using a ranged, partitioned key-value store in a high performance computing (HPC) environment. A plurality of input data files comprising unsorted key-value data in a partitioned key-value store are sorted. The partitioned key-value store comprises a range server for each of a plurality of ranges. Each input data file has an associated reader thread. Each reader thread reads the unsorted key-value data in the corresponding input data file and performs a local sort of the unsorted key-value data to generate sorted key-value data. A plurality of sorted, ranged subsets of each of the sorted key-value data are generated based on the plurality of ranges. Each sorted, ranged subset corresponds to a given one of the ranges and is provided to one of the range servers corresponding to the range of the sorted, ranged subset. Each range server sorts the received sorted, ranged subsets and provides a sorted range. A plurality of the sorted ranges are concatenated to obtain a globally sorted result.
Pre-concentration technique for reduction in "Analytical instrument requirement and analysis"
NASA Astrophysics Data System (ADS)
Pal, Sangita; Singha, Mousumi; Meena, Sher Singh
2018-04-01
Availability of analytical instruments for a methodical detection of known and unknown effluents imposes a serious hindrance in qualification and quantification. Several analytical instruments such as Elemental analyzer, ICP-MS, ICP-AES, EDXRF, ion chromatography, Electro-analytical instruments which are not only expensive but also time consuming, required maintenance, damaged essential parts replacement which are of serious concern. Move over for field study and instant detection installation of these instruments are not convenient to each and every place. Therefore, technique such as pre-concentration of metal ions especially for lean stream elaborated and justified. Chelation/sequestration is the key of immobilization technique which is simple, user friendly, most effective, least expensive, time efficient; easy to carry (10g - 20g vial) to experimental field/site has been demonstrated.
Soylak, Mustafa; Erdogan, Nilgun D
2006-09-21
A simple and facile preconcentration procedure based on the coprecipitation of trace heavy metal ions with copper(II)-rubeanic acid complex has been developed. The analytical parameters including pH, amounts of rubeanic acid, sample volume, etc. was investigated for the quantitative recoveries of Pb(II), Fe(III), Cd(II), Au(III), Pd(II) and Ni(II). No interferic effects were observed from the concomitant ions. The detection limits for analyte ions by 3 sigma were in the range of 0.14 microg/l for iron-3.4 microg/l for lead. The proposed coprecipitation method was successfully applied to water samples from Palas Lake-Kayseri, soil and sediment samples from Kayseri and Yozgat-Turkey.
Kemmei, Tomoko; Kodama, Shuji; Fujishima, Hironori; Yamamoto, Atsushi; Inoue, Yoshinori; Hayakawa, Kazuichi
2012-01-04
The chelating agent EDTA is widely used, and as a result is showing up widely in the aquatic environment. Here we describe a preconcentration procedure for measuring EDTA concentration in sea water samples by HPLC. The procedure consists of forming an Fe(III) complex followed by solid-phase extraction using an activated carbon cartridge. After the preconcentration, EDTA was quantified by HPLC with ultraviolet detection (260 nm). The enrichment permitted the determination of EDTA at concentrations as low as 1 nM. Good recoveries were obtained for both brackish and full-strength sea water with high repeatability (RSD<6%). The method was applied to sea water samples taken from near the mouth of the Oyabe River in Japan. Copyright © 2011 Elsevier B.V. All rights reserved.
Manginell, Ronald P; Moorman, Matthew W; Wheeler, David R
2014-05-27
A microfabricated capacitive chemical sensor can be used as an autonomous chemical sensor or as an analyte-sensitive chemical preconcentrator in a larger microanalytical system. The capacitive chemical sensor detects changes in sensing film dielectric properties, such as the dielectric constant, conductivity, or dimensionality. These changes result from the interaction of a target analyte with the sensing film. This capability provides a low-power, self-heating chemical sensor suitable for remote and unattended sensing applications. The capacitive chemical sensor also enables a smart, analyte-sensitive chemical preconcentrator. After sorption of the sample by the sensing film, the film can be rapidly heated to release the sample for further analysis. Therefore, the capacitive chemical sensor can optimize the sample collection time prior to release to enable the rapid and accurate analysis of analytes by a microanalytical system.
Hinsmann, P; Arce, L; Ríos, A; Valcárcel, M
2000-01-07
The separation of seven pesticides by micellar electrokinetic capillary chromatography in spiked water samples is described, allowing the analysis of pesticides mixtures down to a concentration of 50 microg l(-1) in less than 13 min. Calibration, pre-concentration, elution and injection into the sample vial was carried out automatically by a continuous flow system (CFS) coupled to a capillary electrophoresis system via a programmable arm. The whole system was electronically coupled by a micro-processor and completely controlled by a computer. A C18 solid-phase mini-column was used for the pre-concentration, allowing a 12-fold enrichment (as an average value) of the pesticides from fortified water samples. Under the optimal extraction conditions, recoveries between 90 and 114% for most of the pesticides were obtained.
A model for a transition from a quasicrystalline to a microcrystalline state
NASA Astrophysics Data System (ADS)
Coddens, G.; Launois, P.
1991-07-01
We propose a monoatomic model for a quasicrystal transition as observed recently in systems with icosahedral [3] and decagonal [5] symmetry. It is developed here for the case of decagonal symmetry and is inspired by the experimental results on the system Al-Cu-Co-Si [5,6]. The model goes beyond the purely geometrical description by an important physical aspect: the transition mediates through a single atomic jump distance such that only one unique double-well potential has to be invoked to describe it; in conformity with the symmetry there are 10 jump vectors. In the framework of the model, the microcrystalline state is energetically more favourable than a monocrystalline approximant phase. Nous proposons un modèle mono-atomique pour une transition quasicristal-microcristal du type de celles observées récemment dans des systèmes à symétrie icosaédrique [3] et décagonale [5]. Il est développé ici pour la symétrie décagonale et est inspiré par des résultats expérimentaux concernant l'alliage Al-Cu-Co-Si [5,6]. Le modèle va au-delà d'une description purement géometrique par un aspect physique important : la transition se fait via une seule distance de saut inter-atomique de telle sorte q'un seul double-puits de potentiel doit être pris en compte ; conformément à la symétrie, il y a 10 directions de saut. Dans le cadre du modèle, la phase microcristalline est énergétiquement favorisée par rapport à une phase approximante monocristalline.
Denni Algorithm An Enhanced Of SMS (Scan, Move and Sort) Algorithm
NASA Astrophysics Data System (ADS)
Aprilsyah Lubis, Denni; Salim Sitompul, Opim; Marwan; Tulus; Andri Budiman, M.
2017-12-01
Sorting has been a profound area for the algorithmic researchers, and many resources are invested to suggest a more working sorting algorithm. For this purpose many existing sorting algorithms were observed in terms of the efficiency of the algorithmic complexity. Efficient sorting is important to optimize the use of other algorithms that require sorted lists to work correctly. Sorting has been considered as a fundamental problem in the study of algorithms that due to many reasons namely, the necessary to sort information is inherent in many applications, algorithms often use sorting as a key subroutine, in algorithm design there are many essential techniques represented in the body of sorting algorithms, and many engineering issues come to the fore when implementing sorting algorithms., Many algorithms are very well known for sorting the unordered lists, and one of the well-known algorithms that make the process of sorting to be more economical and efficient is SMS (Scan, Move and Sort) algorithm, an enhancement of Quicksort invented Rami Mansi in 2010. This paper presents a new sorting algorithm called Denni-algorithm. The Denni algorithm is considered as an enhancement on the SMS algorithm in average, and worst cases. The Denni algorithm is compared with the SMS algorithm and the results were promising.
Rashidi Nodeh, Hamid; Wan Ibrahim, Wan Aini; Ali, Imran; Sanagi, Mohd Marsin
2016-05-01
New-generation adsorbent, Fe3O4@SiO2/GO, was developed by modification of graphene oxide (GO) with silica-coated (SiO2) magnetic nanoparticles (Fe3O4). The synthesized adsorbent was characterized using Fourier transform infrared spectroscopy, X-ray diffractometry, energy-dispersive X-ray spectroscopy, and field emission scanning electron microscopy. The developed adsorbent was used for the removal and simultaneous preconcentration of As(III) and As(V) from environmental waters prior to ICP-MS analysis. Fe3O4@SiO2/GO provided high adsorption capacities, i.e., 7.51 and 11.46 mg g(-1) for As(III) and As(V), respectively, at pH 4.0. Adsorption isotherm, kinetic, and thermodynamic were investigated for As(III) and As(V) adsorption. Preconcentration of As(III) and As(V) were studied using magnetic solid-phase extraction (MSPE) method at pH 9.0 as the adsorbent showed selective adsorption for As(III) only in pH range 7-10. MSPE using Fe3O4@SiO2/GO was developed with good linearities (0.05-2.0 ng mL(-1)) and high coefficient of determination (R (2) = 0.9992 and 0.9985) for As(III) and As(V), respectively. The limits of detection (LODs) (3× SD/m, n = 3) obtained were 7.9 pg mL(-1) for As(III) and 28.0 pg mL(-1) for As(V). The LOD obtained is 357-1265× lower than the WHO maximum permissible limit of 10.0 ng mL(-1). The developed MSPE method showed good relative recoveries (72.55-109.71 %) and good RSDs (0.1-4.3 %, n = 3) for spring water, lake, river, and tap water samples. The new-generation adsorbent can be used for the removal and simultaneous preconcentration of As(III) and As(V) from water samples successfully. The adsorbent removal for As(III) is better than As(V).
Zhang, Qiyang; Gong, Maojun
2016-06-10
Flow-gated capillary electrophoresis (CE) coupled with microdialysis has become an important tool for in vivo bioanalytical measurements because it is capable of performing rapid and efficient separations of complex biological mixtures thus enabling high temporal resolution in chemical monitoring. However, the limit of detection (LOD) is often limited to a micro- or nano-molar range while many important target analytes have picomolar or sub-nanomolar levels in brain and other tissues. To enhance the capability of flow-gated CE for catecholamine detection, a novel and simple on-line sample preconcentration method was developed exclusively for fluorescent derivatives of catecholamines that were fluorogenically derivatized with naphthalene-2,3-dicarboxaldehyde (NDA) in the presence of cyanide. The effective preconcentration coupled with the sensitive laser-induced fluorescence (LIF) detection lowered the LOD down to 20pM for norepinephrine (NE) and 50pM for dopamine (DA) at 3-fold of S/N ratio, and the signal enhancement was estimated to be over 100-fold relative to normal injection when standard analytes were dissolved in artificial cerebrospinal fluid (aCSF). The basic focusing principle is novel since the sample plug contains borate while the background electrolyte (BGE) is void of borate. This strategy took advantage of the complexation between diols and borate, through which one negative charge was added to the complex entity. The sample derivatization mixture was electrokinetically injected into a capillary via the flow-gated injection, and then NE and DA derivatives were selectively focused to a narrow zone by the reversible complexation. Separation of NE and DA derivatives was executed by incoming surfactants of cholate and deoxycholate mixed in the front BGE plug. This on-line preconcentration method was finally applied to the detection of DA in rat cerebrospinal fluid (CSF) via microdialysis and on-line derivatization. It is anticipated that the method would be valuable for in vivo monitoring of DA and NE in various brain regions of live animals on flow-gated CE or microchip platforms. Published by Elsevier B.V.
Rmax: A systematic approach to evaluate instrument sort performance using center stream catch☆
Riddell, Andrew; Gardner, Rui; Perez-Gonzalez, Alexis; Lopes, Telma; Martinez, Lola
2015-01-01
Sorting performance can be evaluated with regard to Purity, Yield and/or Recovery of the sorted fraction. Purity is a check on the quality of the sample and the sort decisions made by the instrument. Recovery and Yield definitions vary with some authors regarding both as how efficient the instrument is at sorting the target particles from the original sample, others distinguishing Recovery from Yield, where the former is used to describe the accuracy of the instrument’s sort count. Yield and Recovery are often neglected, mostly due to difficulties in their measurement. Purity of the sort product is often cited alone but is not sufficient to evaluate sorting performance. All of these three performance metrics require re-sampling of the sorted fraction. But, unlike Purity, calculating Yield and/or Recovery calls for the absolute counting of particles in the sorted fraction, which may not be feasible, particularly when dealing with rare populations and precious samples. In addition, the counting process itself involves large errors. Here we describe a new metric for evaluating instrument sort Recovery, defined as the number of particles sorted relative to the number of original particles to be sorted. This calculation requires only measuring the ratios of target and non-target populations in the original pre-sort sample and in the waste stream or center stream catch (CSC), avoiding re-sampling the sorted fraction and absolute counting. We called this new metric Rmax, since it corresponds to the maximum expected Recovery for a particular set of instrument parameters. Rmax is ideal to evaluate and troubleshoot the optimum drop-charge delay of the sorter, or any instrument related failures that will affect sort performance. It can be used as a daily quality control check but can be particularly useful to assess instrument performance before single-cell sorting experiments. Because we do not perturb the sort fraction we can calculate Rmax during the sort process, being especially valuable to check instrument performance during rare population sorts. PMID:25747337
Ensafi, Ali A; Khayamian, Taghi; Karbasi, Mohammad H
2003-06-01
An on-line system for enrichment and determination of lead(II) is presented. It is based on the adsorption of lead(II) ions on a minicolumn packed with active carbon loaded with Pyrogallol Red. After preconcentration step, the metal ions are eluted automatically by 5.0 ml of 0.50 M nitric acid solution and the lead ion contents were determined by atomic absorption spectrometry. The influence of chemicals, pH and flow variables were studied as well as effect of potential interfering ions. Under the optimum conditions, the lead ions in aqueous samples were concentrated about 100 fold by the column. The detection limit was 0.001 microg ml(-1). The recovery percent of spliced lead(II) was in the range of 98%-103%.
Inomata, Y; Matsunaga, K; Murai, Y; Osada, K; Iwasaka, Y
1999-12-09
A method for the simultaneous measurement of volatile sulfur compounds (COS, H2S, CS2, CH3SH, DMS) is established with preconcentration and GC-flame photometric detection (FPD). Prior to preconcentration of ambient air, it was necessary to remove SO2, water vapor and atmospheric oxidant. SO2 and water vapor were removed using a glass fiber filter and a cooled PTFE water trap loop, respectively. In order to remove atmospheric oxidant, the efficiency of an ascorbic acid scrubber was examined. It was found that an ascorbic acid scrubber enabled measurement of volatile sulfur compounds without adsorption and reaction loss. The detection limits for COS, H2S, CS2, CH3SH and DMS were 20, 34, 35, 263 and 44 pg of S, respectively.
Guerreiro, António; Soares, Ana; Piletska, Elena; Mattiasson, Bo; Piletsky, Sergey
2008-03-31
Molecularly imprinted (MIP) and blank polymers with affinity for nonylphenol were designed using computational modelling. Chromatographic tests demonstrated higher affinity of imprinted polymers towards the template nonylphenol as compared with blank polymers. The performance of both polymers in solid-phase extraction was however very similar. Both blank and imprinted polymers appeared to be suitable for the removal and pre-concentration of nonylphenol from contaminated water samples with 99% efficiency of the recovery. The commercial resins PH(EC) (Biotage) and C18 (Varian) tested in the same conditions used for comparative purposes had recovery rate <84%. The polymer capacity for nonylphenol was 231 mg g(-1) for blank and 228 mg g(-1) for MIP. The synthesised materials can have significance for sample pre-concentration and environmental analysis of this class of compounds.
Horká, Marie; Horký, Jaroslav; Kubesová, Anna; Zapletalová, Eva; Slais, Karel
2011-07-01
Trace analysis of microorganisms in real biological samples needs very sensitive methods for their detection. Most procedures for detecting and quantifying pathogens require a sample preparation step including concentrating microorganisms from large sample volumes with high and reproducible efficiency. Electromigration techniques have great potential to include the preconcentration, separation, and detection of whole cells and therefore they can rapidly indicate the presence of pathogens. The preconcentration and separation of microorganisms from real suspensions utilising a combination of filtration and capillary isoelectric focusing was developed and the possibility for its application to real samples was verified. For our experiments, spores of Monilinia species and of Penicillium expansum were selected as model bioparticles, as they cause major losses in agrosystems. The isoelectric points of the spores of M. laxa, M. fructigena, M. fruticola, and P. expansum were determined and the method was verified using real samples taken directly from infected apples. The coupling of a filtration cartridge with a separation capillary can improve the detection limit of isoelectric focusing with UV detection by at least 4 orders of magnitude. Spores of M. fructigena and of M. laxa in numbers of hundreds of particles per milliliter were detected on a visually noninfected apple surface which was cross-contaminated during handling and storage. The efficiency of preconcentration and a preliminary identification was verified by the phenotyping technique after cultivation of the spores sampled from the apple surface.
Tang, Tao; Qian, Kun; Shi, Tianyu; Wang, Fang; Li, Jianqiang; Cao, Yongsong
2010-11-08
A preconcentration technique known as cloud point extraction was developed for the determination of trace levels of triazole fungicides tricyclazole, triadimefon, tebuconazole and diniconazole in environmental waters. The triazole fungicides were extracted and preconcentrated using polyethylene glycol 600 monooleate (PEG600MO) as a low toxic and environmentally benign nonionic surfactant, and determined by high performance liquid chromatography/ultraviolet detection (HPLC-UV). The extraction conditions were optimized for the four triazole fungicides as follows: 2.0 wt% PEG600MO, 2.5 wt% Na(2)SO(4), equilibration at 45°C for 10 min, and centrifugation at 2000 rpm (533 × g) for 5 min. The triazole fungicides were well separated on a reversed-phase kromasil ODS C(18) column (250 mm × 4.6 mm, 5 μm) with gradient elution at ambient temperature and detected at 225 nm. The calibration range was 0.05-20 μg L(-1) for tricyclazole and 0.5-20 μg L(-1) for the other three classes of analytes with the correlation coefficients over 0.9992. Preconcentration factors were higher than 60-fold for the four selected fungicides. The limits of detection were 6.8-34.5 ng L(-1) (S/N=3) and the recoveries were 82.0-96.0% with the relative standard deviations of 2.8-7.8%. Copyright © 2010 Elsevier B.V. All rights reserved.
Ziaei, Ehsan; Mehdinia, Ali; Jabbari, Ali
2014-11-19
New mercapto-grafted graphene oxide-magnetic chitosan (GO-MC) has been developed as a novel biosorbent for the preconcentration and extraction of mercury ion from water samples. A facile and ecofriendly synthesis procedure was also developed for modification of GO-MC with 3-mercaptopropyltrimethoxysilane. The prepared nanocomposite material (mercapto/GO-MC) was characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), Fourier transform infrared spectroscopy (FT-IR) and energy-dispersive X-ray spectroscopy (EDX). The mercury analysis was performed by continuous-flow cold vapor atomic absorption spectrometry. The parameters affecting the extraction and preconcentration processes were carried out. The optimum conditions were found to be 60mg of sorbent, pH of 6.5, 10min for adsorption time, 3mL of HCl (0.1mol L(-1))/thiourea (2% w/v) as the eluent and 250mL for breakthrough volume. An excellent linearity was achieved in the range of 0.12-80ng mL(-1) (R(2)=0.999) at a preconcentration factor of 80. The limit of detection and quantification were achieved as 0.06ng mL(-1) and 0.12ng mL(-1), respectively. A good repeatability was obtained with the relative standard deviation (RSD) of 4.7%. Furthermore, real water samples were analyzed and good recoveries were obtained from 95 to 100%. Copyright © 2014 Elsevier B.V. All rights reserved.
Espina-Benitez, Maria; Araujo, Lilia; Prieto, Avismelsi; Navalón, Alberto; Vílchez, José Luis; Valera, Paola; Zambrano, Ana; Dugas, Vincent
2017-07-07
A new analytical method coupling a (off-line) solid-phase microextraction with an on-line capillary electrophoresis (CE) sample enrichment technique was developed for the analysis of ketoprofen, naproxen and clofibric acid from water samples, which are known as contaminants of emerging concern in aquatic environments. New solid-phase microextraction fibers based on physical coupling of chromatographic supports onto epoxy glue coated needle were studied for the off-line preconcentration of these micropollutants. Identification and quantification of such acidic drugs were done by capillary zone electrophoresis (CZE) using ultraviolet diode array detection (DAD). Further enhancement of concentration sensitivity detection was achieved by on-line CE "acetonitrile stacking" preconcentration technique. Among the eight chromatographic supports investigated, Porapak Q sorbent showed higher extraction and preconcentration capacities. The screening of parameters that influence the microextraction process was carried out using a two-level fractional factorial. Optimization of the most relevant parameters was then done through a surface response three-factor Box-Behnken design. The limits of detection and limits of quantification for the three drugs ranged between 0.96 and 1.27 µg∙L -1 and 2.91 and 3.86 µg∙L -1 , respectively. Recovery yields of approximately 95 to 104% were measured. The developed method is simple, precise, accurate, and allows quantification of residues of these micropollutants in Genil River water samples using inexpensive fibers.
Abdolmohammad-Zadeh, Hossein; Jouyban, Abolghasem; Amini, Roghayeh
2013-11-15
A selective solid phase extraction method, based on nano-structured Mg-Al-Fe(NO3(-)) ternary layered double hydroxide as a sorbent, is developed for the pre-concentration of ultra-trace levels of arsenic (As) prior to determination by electrothermal atomic absorption spectrometry. It is found that both As(III) and As(V) could be quantitatively retained on the sorbent within a wide pH range of 4-12. Accordingly, the presented method is applied to determination of total inorganic As in aqueous solutions. Maximum analytical signal of As is achieved when the pyrolysis and atomization temperatures are close to 900 °C and 2300 °C, respectively. Several variables affecting the extraction efficiency including pH, sample flow rate, amount of nano-sorbent, elution conditions and sample volume are optimized. Under the optimized conditions, the limit of detection (3Sb/m) and the relative standard deviation are 4.6 pg mL(-1) and 3.9%, respectively. The calibration graph is linear in the range of 15.0-650 pg mL(-1) with a correlation coefficient of 0.9979, sorption capacity and pre-concentration factor are 8.68 mg g(-1) and 300, respectively. The developed method is validated by the analysis of a standard reference material (SRM 1643e) and is successfully applied to the determination of ultra-trace amounts of As in different water samples. Copyright © 2013 Elsevier B.V. All rights reserved.
Fasih Ramandi, Negin; Shemirani, Farzaneh
2015-01-01
For the first time, a selective ionic liquid ferrofluid has been used in dispersive solid phase extraction (IL-FF-D-SPE) for simultaneous preconcentration and separation of lead and cadmium in milk and biological samples combined with flame atomic absorption spectrometry. To improve the selectivity of the ionic liquid ferrofluid, the surface of TiO2 nanoparticles with a magnetic core as sorbent was modified by loading 1-(2-pyridylazo)-2-naphtol. Due to the rapid injection of an appropriate amount of ionic liquid ferrofluid into the aqueous sample by a syringe, extraction can be achieved within a few seconds. In addition, based on the attraction of the ionic liquid ferrofluid to a magnet, no centrifugation step is needed for phase separation. The experimental parameters of IL-FF-D-SPE were optimized using a Box-Behnken design (BBD) after a Plackett-Burman screening design. Under the optimum conditions, the relative standard deviations of 2.2% and 2.4% were obtained for lead and cadmium, respectively (n=7). The limit of detections were 1.21 µg L(-1) for Pb(II) and 0.21 µg L(-1) for Cd(II). The preconcentration factors were 250 for lead and 200 for cadmium and the maximum adsorption capacities of the sorbent were 11.18 and 9.34 mg g(-1) for lead and cadmium, respectively. Copyright © 2014 Elsevier B.V. All rights reserved.
Chen, Miao; Xia, Qinghai; Liu, Mousheng; Yang, Yaling
2011-01-01
A cloud-point extraction (CPE) method using Triton X-114 (TX-114) nonionic surfactant was developed for the extraction and preconcentration of propyl gallate (PG), tertiary butyl hydroquinone (TBHQ), butylated hydroxyanisole (BHA), and butylated hydroxytoluene (BHT) from edible oils. The optimum conditions of CPE were 2.5% (v/v) TX-114, 0.5% (w/v) NaCl and 40 min equilibration time at 50 °C. The surfactant-rich phase was then analyzed by reversed-phase high-performance liquid chromatography with ultraviolet detection at 280 nm, using a gradient mobile phase consisting of methanol and 1.5% (v/v) acetic acid. Under the studied conditions, 4 synthetic phenolic antioxidants (SPAs) were successfully separated within 24 min. The limits of detection (LOD) were 1.9 ng mL(-1) for PG, 11 ng mL(-1) for TBHQ, 2.3 ng mL(-1) for BHA, and 5.9 ng mL(-1) for BHT. Recoveries of the SPAs spiked into edible oil were in the range 81% to 88%. The CPE method was shown to be potentially useful for the preconcentration of the target analytes, with a preconcentration factor of 14. Moreover, the method is simple, has high sensitivity, consumes much less solvent than traditional methods, and is environment-friendly. Practical Application: The method established in this article uses less organic solvent to extract SPAs from edible oils; it is simple, highly sensitive and results in no pollution to the environment.
Su, Rihui; Ruan, Guihua; Chen, Zhengyi; Du, Fuyou; Li, Jianping
2015-12-01
A new class of solid-phase extraction column prepared with grafted mercapto-silica polymerized high internal phase emulsion particles was used for the preconcentration of trace lead. First, mercapto-silica polymerized high internal phase emulsion particles were synthesized by using high internal phase emulsion polymerization and carefully assembled in a polyethylene syringe column. The influences of various parameters including adsorption pH value, adsorption and desorption solvents, flow rate of the adsorption and desorption procedure were optimized, respectively, and the suitable uploading sample volumes, adsorption capacity, and reusability of solid phase extraction column were also investigated. Under the optimum conditions, Pb(2+) could be preconcentrated quantitatively over a wide pH range (2.0-5.0). In the presence of foreign ions, such as Na(+) , K(+) , Ca(2+) , Zn(2+) , Mg(2+) , Cu(2+) , Fe(2+) , Cd(2+) , Cl(-) and NO3 (-) , Pb(2+) could be recovered successfully. The prepared solid-phase extraction column performed with high stability and desirable durability, which allowed more than 100 replicate extractions without measurable changes of performance. The feasibility of the developed method was further validated by the extraction of Pb(2+) in rice samples. At three spiked levels of 40.0, 200 and 800 μg/kg, the average recoveries for Pb(2+) in rice samples ranged from 87.3 to 105.2%. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Araujo, Lilia; Prieto, Avismelsi; Navalón, Alberto; Vílchez, José Luis; Valera, Paola; Zambrano, Ana; Dugas, Vincent
2017-01-01
A new analytical method coupling a (off-line) solid-phase microextraction with an on-line capillary electrophoresis (CE) sample enrichment technique was developed for the analysis of ketoprofen, naproxen and clofibric acid from water samples, which are known as contaminants of emerging concern in aquatic environments. New solid-phase microextraction fibers based on physical coupling of chromatographic supports onto epoxy glue coated needle were studied for the off-line preconcentration of these micropollutants. Identification and quantification of such acidic drugs were done by capillary zone electrophoresis (CZE) using ultraviolet diode array detection (DAD). Further enhancement of concentration sensitivity detection was achieved by on-line CE “acetonitrile stacking” preconcentration technique. Among the eight chromatographic supports investigated, Porapak Q sorbent showed higher extraction and preconcentration capacities. The screening of parameters that influence the microextraction process was carried out using a two-level fractional factorial. Optimization of the most relevant parameters was then done through a surface response three-factor Box-Behnken design. The limits of detection and limits of quantification for the three drugs ranged between 0.96 and 1.27 µg∙L−1 and 2.91 and 3.86 µg∙L−1, respectively. Recovery yields of approximately 95 to 104% were measured. The developed method is simple, precise, accurate, and allows quantification of residues of these micropollutants in Genil River water samples using inexpensive fibers. PMID:28686186
NASA Astrophysics Data System (ADS)
Rajabi, Hamid Reza; Razmpour, Saham
2016-01-01
Here, the researchers report on the synthesis of ion imprinted polymeric (IIP) nanoparticles using a thermal polymerization strategy, and their usage for the separation of Ni2 + ion from water samples. The prepared Ni-IIP was characterized by colorimetry, FT-IR spectroscopy, and scanning electron microscopy. It was found that the particle size of the prepared particle to be 50-70 nm in diameter with the highly selective binding capability for Ni2 + ion, with reasonable adsorption and desorption process. After preconcentration, bound ions can be eluted with an aqueous solution of hydrochloric acid, after their complexation with dimethylglyoxime, these ions can be quantified by UV-Vis absorption spectrophotometry. The effect of various parameters on the extraction efficiency including pH of sample solution, adsorption and leaching times, initial sample volume, concentration and volume of eluent were investigated. In selectivity study, it was found that imprinting causes increased affinity of the prepared IIP toward Ni2 + ion over other ions such as Na+, K+, Ag+, Co2 +, Cu2 +, Cd2 +, Hg2 +, Pb2 +, Zn2 +, Mn2 +, Mg2 +, Cr3 +, and Fe3 +. The prepared IIP can be used and regenerated for at least eight times without any significant decrease in binding affinities. The prepared IIP is considered to be promising and selective sorbent for solid-phase extraction and preconcentration of Ni2 + ion from different water samples.
Mashile, Geaneth Pertunia; Mpupa, Anele; Nomngongo, Philiswa Nosizo
2018-06-14
In this study, a simple, rapid and effective in-syringe micro-solid phase extraction (MSPE) method was developed for the separation and preconcetration of parabens (methyl, ethyl, propyl and butyl paraben) in environmental water samples. The parabens were determined and quantified using high performance liquid chromatography and a photo diode array detector (HPLC-PDA). Chitosan-coated activated carbon (CAC) was used as the sorbent in the in-syringe MSPE device. A response surface methodology based on central composite design was used for the optimization of factors (eluent solvent type, eluent volume, number of elution cycles, sample volume, sample pH) affecting the extraction efficiency of the preconcentration procedure. The adsorbent used displayed excellent absorption performance and the adsorption capacity ranged from 227⁻256 mg g −1 . Under the optimal conditions the dynamic linear ranges for the parabens were between 0.04 and 380 µg L −1 . The limits of detection and quantification ranged from 6⁻15 ng L −1 and 20⁻50 ng L −1 , respectively. The intraday (repeatability) and interday (reproducibility) precisions expressed as relative standard deviations (%RSD) were below 5%. Furthermore, the in-syringe MSPE/HPLC procedure was validated using spiked wastewater and tap water samples and the recoveries ranged between from 96.7 to 107%. In conclusion, CAC based in-syringe MSPE method demonstrated great potential for preconcentration of parabens in complex environmental water.
Ghasemi, Ensieh; Sillanpää, Mika
2014-12-01
In this study, a simple, novel and efficient preconcentration method for the determination of some chlorobenzenes (monochlorobenzene (MCB), three isomeric forms of dichlorobenzene (diCB), 1,3,5-trichlorobenzene (triCB) and hexachlorobenze (hexaCB)) has been developed using a headspace solid phase microextraction (HS-SPME) based on nano-structured ZnO combined with capillary gas chromatography-mass spectrometry (GC-MS). ZnO nanorods have been grown on fused silica fibers using a hydrothermal process. The diameter of ZnO nanorods was in the range of 50-80 nm. The effect of different variables on the extraction efficiency was studied simultaneously using an experimental design. The variables of interest in the HS-SPME were stirring rate, desorption time and temperature, ionic strength, extraction time and temperature. For this purpose, a multivariate strategy was applied based on an experimental design using a Plackett-Burman design for screening and a Box-Behnken design for optimizing of the significant factors. The detection limit and relative standard deviation (RSD) (n=5) for the target analytes were in the range of 0.01-0.1 ng L(-1) and 4.3-7.6%, respectively. The developed technique was found to be successfully applicable to preconcentration and determination of the target analytes in environmental water and soil samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Dadfarnia, Shayessteh; Shabani, Ali Mohammad Haji; Shakerian, Farid; Shiralian Esfahani, Golnaz
2013-12-15
A simple and sensitive method for the separation and preconcentration of the ultra trace amounts of uranium and its determination by spectrophotometry was developed. The method is based on the combination of solid phase extraction and dispersive liquid-liquid microextraction. Thus, by passing the sample through the basic alumina column, the uranyl ion and some cations are separated from the sample matrix. The retained uranyl ion along with the cations are eluted with 5 mL of nitric acid (2 mol L(-1)) and after neutralization of the eluent, the extracted uranyl ion is converted to its anionic benzoate complex and is separated from other cations by extraction of its ion pair with malachite green into small volume of chloroform using dispersive liquid-liquid microextraction. The amount of uranium is then determined by the absorption measurement of the extracted ion pair at 621 nm using flow injection spectrophotometry. Under the optimum conditions, with 500 mL of the sample, a preconcentration factor of 1980, a detection limit of 40 ng L(-1), and a relative standard deviation of 4.1% (n=6) at 400 ng L(-1) were obtained. The method was successfully applied to the determination of uranium in mineral water, river water, well water, spring water and sea water samples. Copyright © 2013 Elsevier B.V. All rights reserved.
González García, M M; Sánchez Rojas, F; Bosch Ojeda, C; García de Torres, A; Cano Pavón, J M
2003-04-01
A method to determine trace amounts of platinum in different samples based on electrothermal atomic absorption spectrometry is described. The preconcentration step is performed on a chelating resin microcolumn [1,5-bis(2-pyridyl)-3-sulfophenyl methylene thiocarbonohydrazide (PSTH) immobilized on an anion-exchange resin (Dowex 1x8-200)] placed in the autosampler arm. The combination of a peristaltic pump for sample loading and the atomic absorption spectrometer pumps for elution through a selection valve simplifies the hardware. The peristaltic pump and the selection valve are easily controlled electronically with two switches placed in the autosampler, which are activated when the autosampler arm is down. Thus, the process is fully automated without any modification of the software of the atomic absorption spectrometer. Under the optimum conditions with a 60-s preconcentration time, a sample flow rate of 2.4 mL min(-1), and an injection volume of eluent of 40 microL, a linear calibration graph was obtained in the range 0-100 ng mL(-1). The enrichment factor was 14. The detection limit under these conditions is 1 ng mL(-1), and the relative standard deviation (RSD) is 1.6% for 10 ng mL(-1) of Pt. The method has been applied to the determination of platinum in catalyst, vegetation, soil, and natural water samples. The results showed good agreement with the certified value and the recoveries of Pt added to samples were 98-105%.
Parallel integer sorting with medium and fine-scale parallelism
NASA Technical Reports Server (NTRS)
Dagum, Leonardo
1993-01-01
Two new parallel integer sorting algorithms, queue-sort and barrel-sort, are presented and analyzed in detail. These algorithms do not have optimal parallel complexity, yet they show very good performance in practice. Queue-sort designed for fine-scale parallel architectures which allow the queueing of multiple messages to the same destination. Barrel-sort is designed for medium-scale parallel architectures with a high message passing overhead. The performance results from the implementation of queue-sort on a Connection Machine CM-2 and barrel-sort on a 128 processor iPSC/860 are given. The two implementations are found to be comparable in performance but not as good as a fully vectorized bucket sort on the Cray YMP.
NASA Technical Reports Server (NTRS)
Dorband, John E.
1988-01-01
Sorting has long been used to organize data in preparation for further computation, but sort computation allows some types of computation to be performed during the sort. Sort aggregation and sort distribution are the two basic forms of sort computation. Sort aggregation generates an accumulative or aggregate result for each group of records and places this result in one of the records. An aggregate operation can be any operation that is both associative and commutative, i.e., any operation whose result does not depend on the order of the operands or the order in which the operations are performed. Sort distribution copies the value from a field of a specific record in a group into that field in every record of that group.
Derivation of sorting programs
NASA Technical Reports Server (NTRS)
Varghese, Joseph; Loganantharaj, Rasiah
1990-01-01
Program synthesis for critical applications has become a viable alternative to program verification. Nested resolution and its extension are used to synthesize a set of sorting programs from their first order logic specifications. A set of sorting programs, such as, naive sort, merge sort, and insertion sort, were successfully synthesized starting from the same set of specifications.
Spin-the-bottle Sort and Annealing Sort: Oblivious Sorting via Round-robin Random Comparisons
Goodrich, Michael T.
2013-01-01
We study sorting algorithms based on randomized round-robin comparisons. Specifically, we study Spin-the-bottle sort, where comparisons are unrestricted, and Annealing sort, where comparisons are restricted to a distance bounded by a temperature parameter. Both algorithms are simple, randomized, data-oblivious sorting algorithms, which are useful in privacy-preserving computations, but, as we show, Annealing sort is much more efficient. We show that there is an input permutation that causes Spin-the-bottle sort to require Ω(n2 log n) expected time in order to succeed, and that in O(n2 log n) time this algorithm succeeds with high probability for any input. We also show there is a specification of Annealing sort that runs in O(n log n) time and succeeds with very high probability. PMID:24550575
Safe sorting of GFP-transduced live cells for subsequent culture using a modified FACS vantage.
Sørensen, T U; Gram, G J; Nielsen, S D; Hansen, J E
1999-12-01
A stream-in-air cell sorter enables rapid sorting to a high purity, but it is not well suited for sorting of infectious material due to the risk of airborne spread to the surroundings. A FACS Vantage cell sorter was modified for safe use with potentially HIV infected cells. Safety tests with bacteriophages were performed to evaluate the potential spread of biologically active material during cell sorting. Cells transduced with a retroviral vector carrying the gene for GFP were sorted on the basis of their GFP fluorescence, and GFP expression was followed during subsequent culture. The bacteriophage sorting showed that the biologically active material was confined to the sorting chamber. A failure mode simulating a nozzle blockage resulted in detectable droplets inside the sorting chamber, but no droplets could be detected when an additional air suction from the sorting chamber had been put on. The GFP transduced cells were sorted to 99% purity. Cells not expressing GFP at the time of sorting did not turn on the gene during subsequent culture. Un-sorted cells and cells sorted to be positive for GFP showed a decrease in the fraction of GFP positive cells during culture. Sorting of live infected cells can be performed safely and with no deleterious effects on vector expression using the modified FACS Vantage instrument. Copyright 1999 Wiley-Liss, Inc.
Design and realization of sort manipulator of crystal-angle sort machine
NASA Astrophysics Data System (ADS)
Wang, Ming-shun; Chen, Shu-ping; Guan, Shou-ping; Zhang, Yao-wei
2005-12-01
It is a current tendency of development in automation technology to replace manpower with manipulators in working places where dangerous, harmful, heavy or repetitive work is involved. The sort manipulator is installed in a crystal-angle sort machine to take the place of manpower, and engaged in unloading and sorting work. It is the outcome of combing together mechanism, electric transmission, and pneumatic element and micro-controller control. The step motor makes the sort manipulator operate precisely. The pneumatic elements make the sort manipulator be cleverer. Micro-controller's software bestows some simple artificial intelligence on the sort manipulator, so that it can precisely repeat its unloading and sorting work. The combination of manipulator's zero position and step motor counting control puts an end to accumulating error in long time operation. A sort manipulator's design in the practice engineering has been proved to be correct and reliable.
NASA Astrophysics Data System (ADS)
Mas, Sebastien
Les mesures satellitaires de couleur des oceans sont largement determinees par les proprietes optiques inherentes (IOPs) des eaux de surface. D'autre part, le phytoplancton de petite taille (<20 mum) est le plus souvent dominant dans les oceans, et peut donc etre une source importante de variation des IOPs dans les oceans. Dans ce contexte, le but principal de ce doctorat etait de definir l'impact du phytoplancton (<20 mum) sur les variations des proprietes optiques de l'Estuaire et du Golfe du Saint-Laurent (Canada). Afin d'atteindre cet objectif, il etait necessaire de determiner en milieu controle les facteurs de variabilite des proprietes optiques cellulaires et des IOPs du phytoplancton (<20 mum) des eaux du Saint-Laurent, et d'evaluer la contribution du phytoplancton (<20 mum) aux proprietes optiques totales des eaux du Saint-Laurent. Des experiences en laboratoire ont montre que les variations des proprietes optiques des cellules phytoplanctoniques soumises a un cycle jour-nuit, ainsi qu'a des changements concomitants d'intensite lumineuse, peuvent contribuer significativement a la variabilite des proprietes optiques observee en milieu naturel. D'autres experiences ont, quant a elles, mis en evidence que les variations des proprietes optiques des cellules phytoplanctoniques dues aux phases de croissance peuvent alterer les IOPs des oceans, particulierement pendant les periodes de floraison. De plus, la presence de bacteries et de particules detritiques peut egalement affecter la variabilite des IOPs totales, notamment la diffusion. Au printemps, dans l'Estuaire et le Golfe du Saint-Laurent, la contribution du phytoplancton <20 mum aux IOPs presentait des differences regionales evidentes pour les proprietes d'absorption et de diffusion. En plus de la variabilite spatiale, les proprietes optiques cellulaires presentaient des variations journalieres, et ce particulierement pour le picophytoplancton. Enfin, la plupart des differences observees dans les proprietes biooptiques, particulierement l'absorption, etaient attribuables a la contribution du phytoplancton <20 mum. Ceci confirme l'importance de la structure de taille des communautes phytoplanctoniques dans les modeles bio-optiques appliques au Saint-Laurent. L'ensemble des resultats a permis de mettre en evidence l'importance des mecanismes de photoacclimatation et de synchronisation du cycle cellulaire du phytoplancton sur les variations journalieres des IOPs, ainsi que de l'etat physiologique relie au stade de croissance sur les variations temporelles a long terme des IOPs. De plus, le phytoplancton <20 mum contribue de maniere importante aux IOPs et a leur variabilite dans l'Estuaire et le Golfe du St-Laurent, et ce particulierement pour l'absorption. Cette etude de doctorat souligne donc l'importance du phytoplancton <20 mum sur la variabilite des IOPs des oceans.
ERIC Educational Resources Information Center
Grote, Irene; And Others
1996-01-01
Three preschoolers performed four sorts with stimulus cards--an untaught target sort and three directly taught alternating sorts considered to self-instruct the target performance. Accuracy increased first in the skill sorts and then in the untaught target sorts. All subjects generalized to new target sorts. Correct spontaneous self-instructions…
To sort or not to sort: the impact of spike-sorting on neural decoding performance.
Todorova, Sonia; Sadtler, Patrick; Batista, Aaron; Chase, Steven; Ventura, Valérie
2014-10-01
Brain-computer interfaces (BCIs) are a promising technology for restoring motor ability to paralyzed patients. Spiking-based BCIs have successfully been used in clinical trials to control multi-degree-of-freedom robotic devices. Current implementations of these devices require a lengthy spike-sorting step, which is an obstacle to moving this technology from the lab to the clinic. A viable alternative is to avoid spike-sorting, treating all threshold crossings of the voltage waveform on an electrode as coming from one putative neuron. It is not known, however, how much decoding information might be lost by ignoring spike identity. We present a full analysis of the effects of spike-sorting schemes on decoding performance. Specifically, we compare how well two common decoders, the optimal linear estimator and the Kalman filter, reconstruct the arm movements of non-human primates performing reaching tasks, when receiving input from various sorting schemes. The schemes we tested included: using threshold crossings without spike-sorting; expert-sorting discarding the noise; expert-sorting, including the noise as if it were another neuron; and automatic spike-sorting using waveform features. We also decoded from a joint statistical model for the waveforms and tuning curves, which does not involve an explicit spike-sorting step. Discarding the threshold crossings that cannot be assigned to neurons degrades decoding: no spikes should be discarded. Decoding based on spike-sorted units outperforms decoding based on electrodes voltage crossings: spike-sorting is useful. The four waveform based spike-sorting methods tested here yield similar decoding efficiencies: a fast and simple method is competitive. Decoding using the joint waveform and tuning model shows promise but is not consistently superior. Our results indicate that simple automated spike-sorting performs as well as the more computationally or manually intensive methods used here. Even basic spike-sorting adds value to the low-threshold waveform-crossing methods often employed in BCI decoding.
To sort or not to sort: the impact of spike-sorting on neural decoding performance
NASA Astrophysics Data System (ADS)
Todorova, Sonia; Sadtler, Patrick; Batista, Aaron; Chase, Steven; Ventura, Valérie
2014-10-01
Objective. Brain-computer interfaces (BCIs) are a promising technology for restoring motor ability to paralyzed patients. Spiking-based BCIs have successfully been used in clinical trials to control multi-degree-of-freedom robotic devices. Current implementations of these devices require a lengthy spike-sorting step, which is an obstacle to moving this technology from the lab to the clinic. A viable alternative is to avoid spike-sorting, treating all threshold crossings of the voltage waveform on an electrode as coming from one putative neuron. It is not known, however, how much decoding information might be lost by ignoring spike identity. Approach. We present a full analysis of the effects of spike-sorting schemes on decoding performance. Specifically, we compare how well two common decoders, the optimal linear estimator and the Kalman filter, reconstruct the arm movements of non-human primates performing reaching tasks, when receiving input from various sorting schemes. The schemes we tested included: using threshold crossings without spike-sorting; expert-sorting discarding the noise; expert-sorting, including the noise as if it were another neuron; and automatic spike-sorting using waveform features. We also decoded from a joint statistical model for the waveforms and tuning curves, which does not involve an explicit spike-sorting step. Main results. Discarding the threshold crossings that cannot be assigned to neurons degrades decoding: no spikes should be discarded. Decoding based on spike-sorted units outperforms decoding based on electrodes voltage crossings: spike-sorting is useful. The four waveform based spike-sorting methods tested here yield similar decoding efficiencies: a fast and simple method is competitive. Decoding using the joint waveform and tuning model shows promise but is not consistently superior. Significance. Our results indicate that simple automated spike-sorting performs as well as the more computationally or manually intensive methods used here. Even basic spike-sorting adds value to the low-threshold waveform-crossing methods often employed in BCI decoding.
Carlton, Jez G.; Bujny, Miriam V.; Peter, Brian J.; Oorschot, Viola M. J.; Rutherford, Anna; Arkell, Rebecca S.; Klumperman, Judith; McMahon, Harvey T.; Cullen, Peter J.
2006-01-01
Summary Sorting nexins are a large family of phox-homology-domain-containing proteins that have been implicated in the control of endosomal sorting. Sorting nexin-1 is a component of the mammalian retromer complex that regulates retrieval of the cation-independent mannose 6-phosphate receptor from endosomes to the trans-Golgi network. In yeast, retromer is composed of Vps5p (the orthologue of sorting nexin-1), Vps17p (a related sorting nexin) and a cargo selective subcomplex composed of Vps26p, Vps29p and Vps35p. With the exception of Vps17p, mammalian orthologues of all yeast retromer components have been identified. For Vps17p, one potential mammalian orthologue is sorting nexin-2. Here we show that, like sorting nexin-1, sorting nexin-2 binds phosphatidylinositol 3-monophosphate and phosphatidylinositol 3,5-bisphosphate, and possesses a Bin/Amphiphysin/Rvs domain that can sense membrane curvature. However, in contrast to sorting nexin-1, sorting nexin-2 could not induce membrane tubulation in vitro or in vivo. Functionally, we show that endogenous sorting nexin-1 and sorting nexin-2 co-localise on high curvature tubular elements of the 3-phosphoinositide-enriched early endosome, and that suppression of sorting nexin-2 does not perturb the degradative sorting of receptors for epidermal growth factor or transferrin, nor the steady-state distribution of the cation-independent mannose 6-phosphate receptor. However, suppression of sorting nexin-2 results in a subtle alteration in the kinetics of cation-independent mannose 6-phosphate receptor retrieval. These data suggest that although sorting nexin-2 may be a component of the retromer complex, its presence is not essential for the regulation of endosome-to-trans Golgi network retrieval of the cation-independent mannose 6-phosphate receptor. PMID:16179610
La planification préalable des soins pour les patients en pédiatrie
2008-01-01
RÉSUMÉ Les progrès médicaux et technologiques ont permis d’ac-croître les taux de survie et d’améliorer la qualité de vie des nourrissons, des enfants et des adolescents ayant des maladies chroniques mettant la vie en danger. La planifi-cation préalable des soins inclut le processus relié aux discussions sur les traitements essentiels au maintien de la survie et la détermination des objectifs des soins de longue durée. Les dispensateurs de soins pédiatriques ont l’obligation éthique d’assimiler cet aspect des soins médicaux. Le présent document de principes vise à aider les dispensateurs de soins à discuter de la planification préalable des soins des patients pédiatriques dans diverses situations. La planification préalable des soins exige des communications efficaces afin de clarifier les objectifs des soins et de s’entendre sur les traitements pertinents ou non pour réaliser ces objectifs, y compris les mesures de réanimation et les mesures palliatives.
Kahan, Meldon; Wilson, Lynn; Mailis-Gagnon, Angela; Srivastava, Anita
2011-01-01
Résumé Objectif Présenter aux médecins de famille un résumé clinique pratique sur la prescription d’opioïdes à des populations particulières en se fondant sur les recommandations faites dans les lignes directrices canadiennes sur l’utilisation sécuritaire et efficace des opioïdes pour la douleur chronique non cancéreuse. Qualité des données Pour produire les lignes directrices, les chercheurs ont effectué une synthèse critique de la littérature médicale en insistant plus précisément sur les études de l’efficacité et de la sécurité des opioïdes dans des populations particulières. Message principal Les médecins de famille peuvent atténuer les risques de surdose, de sédation, d’usage abusif et de dépendance grâce à des stratégies adaptées à l’âge et à l’état de santé des patients. Dans le cas de patients à risque de dépendance, on devrait réserver les opioïdes aux douleurs nociceptives ou neuropathiques bien définies qui n’ont pas répondu aux traitements de première intention. Il faut procéder lentement au titrage des opioïdes, avec des dispensations fréquentes et une étroite surveillance pour dépister tout signe d’usage abusif. Une dépendance aux opioïdes suspectée est prise en charge au moyen d’une thérapie structurée aux opioïdes, d’un traitement à la méthadone ou à la buprénorphine ou encore d’un traitement fondé sur l’abstinence. Les patients souffrant de troubles de l’humeur ou d’anxiété ont tendance à avoir une réponse analgésique atténuée aux opioïdes, sont à risque plus élevé d’usage abusif et prennent souvent des sédatifs qui interagissent défavorablement avec les opioïdes. Il faut prendre des précautions semblables à celles utilisées avec d’autres patients à risque élevé. Il faut faire un sevrage progressif si la douleur du patient demeure sévère même avec un essai adéquat de thérapie aux opioïdes. Chez les personnes âgées, la sédation, les chutes et la surdose peuvent être minimisées en utilisant des doses initiales faibles, un titrage plus lent, un sevrage des benzodiazépines et une bonne éducation des patients. Dans le cas des femmes enceintes qui prennent des opioïdes chaque jour, il faut faire un sevrage progressif et cesser complètement. Si ce n’est pas possible, il faut administrer la dose efficace la plus faible. Les femmes enceintes qui ont une dépendance aux opioïdes devraient recevoir un traitement à la méthadone. Les adolescents sont à risque élevé de surdose d’opioïdes, d’usage abusif et de dépendance. Les patients qui ont des adolescents qui vivent à la maison devraient entreposer leurs opioïdes dans un lieu sûr. Les adolescents ont rarement besoin d’une thérapie à long terme aux opioïdes. Conclusion Les médecins de famille doivent tenir compte de l’âge, de la condition psychiatrique, du degré de risque de dépendance du patient et d’autres facteurs quand ils prescrivent des opioïdes pour la douleur chronique.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Finzi, S.; Marchetti, C.; Renzoni, R.
The first of four reports on the design of a plant for producing 99.75 mole% D/sub 2/O from preconcentrated solutions is presented. The isotopic and chemicophysical design is treated, all the necessary theoretical considerations for the calculations being given. (T.R.H.)
Pure-rotational spectrometry: a vintage analytical method applied to modern breath analysis.
Hrubesh, Lawrence W; Droege, Michael W
2013-09-01
Pure-rotational spectrometry (PRS) is an established method, typically used to study structures and properties of polar gas-phase molecules, including isotopic and isomeric varieties. PRS has also been used as an analytical tool where it is particularly well suited for detecting or monitoring low-molecular-weight species that are found in exhaled breath. PRS is principally notable for its ultra-high spectral resolution which leads to exceptional specificity to identify molecular compounds in complex mixtures. Recent developments using carbon aerogel for pre-concentrating polar molecules from air samples have extended the sensitivity of PRS into the part-per-billion range. In this paper we describe the principles of PRS and show how it may be configured in several different modes for breath analysis. We discuss the pre-concentration concept and demonstrate its use with the PRS analyzer for alcohols and ammonia sampled directly from the breath.
Integrating preconcentrator heat controller
Bouchier, Francis A.; Arakaki, Lester H.; Varley, Eric S.
2007-10-16
A method and apparatus for controlling the electric resistance heating of a metallic chemical preconcentrator screen, for example, used in portable trace explosives detectors. The length of the heating time-period is automatically adjusted to compensate for any changes in the voltage driving the heating current across the screen, for example, due to gradual discharge or aging of a battery. The total deposited energy in the screen is proportional to the integral over time of the square of the voltage drop across the screen. Since the net temperature rise, .DELTA.T.sub.s, of the screen, from beginning to end of the heating pulse, is proportional to the total amount of heat energy deposited in the screen during the heating pulse, then this integral can be calculated in real-time and used to terminate the heating current when a pre-set target value has been reached; thereby providing a consistent and reliable screen temperature rise, .DELTA.T.sub.s, from pulse-to-pulse.
Crock, J.G.; Lichte, F.E.; Riddle, G.O.; Beech, C.L.
1986-01-01
The abundance of rare-earth elements (REE) and yttrium in geological materials is generally low, and most samples contain elements that interfere in the determination of the REE and Y, so a separation and/or preconcentration step is often necessary. This is often achieved by ion-exchange chromatography with either nitric or hydrochloric acid. It is advantageous, however, to use both acids sequentially. The final solution thus obtained contains only the REE and Y, with minor amounts of Al, Ba, Ca, Sc, Sr and Ti. Elements that potentially interfere, such as Be, Co, Cr, Fe, Mn, Th, U, V and Zr, are virtually eliminated. Inductively-coupled argon plasma atomic-emission spectroscopy can then be used for a final precise and accurate measurement. The method can also be used with other instrumental methods of analysis. ?? 1986.
El-Maali, N A
2000-04-28
The electrochemical behavior of ceftazidime (CFZ) at four different kinds of electrodes viz. static mercury drop electrode (SMDE), controlled growth mercury electrode (CGME), glassy carbon electrode (GCE) and carbon paste electrode (CPE) has been presented. Optimal operational parameters have been selected for the drug preconcentration and determination in aqueous medium. Down to 2x10(-10) M CFZ is achieved as detection limit at the CGME. Modification of the CPE with polyvinyl alcohol (PVA) enhances both the sensitivity and selectivity for the drug accumulation and, therefore, its determination at very low levels. Application of the proposed method for CFZ analysis in spiked urine samples or those taken after metabolism has been easily assessed. Down to 1x10(-9) M CFZ (0.695 ng ml(-1)) could be easily achieved in such samples.
Smith, C.L.; Motooka, J.M.; Willson, W.R.
1984-01-01
Since concentrations of trace elements in most natural waters seldom exceed the ??g/L level, analysis of trace elements in natural waters by inductively coupled plasma emission spectrometry (ICP) requires a preconcentration procedure. The elements Ag, Bi, Cd, Co, Cu, Fe, Mo, Ni, Pb, Sn, V, W, and Zn were separated and concentrated from 500 mL of water by coprecipitating them with sodium dibenzyldithiocarbamate (NaDBDTC) using nickel or silver as a carrier. The precipitated trace elements were collected on a membrane filter, redissolved from the filter with hot nitric and hydrochloric acids, and analyzed using ICP. Recoveries for all the trace elements except tungsten exceeded 80%. Coprecipitation of trace elements with NaDBDTC eliminated the use of difficult-to-inject organic solvents, and NaDBDTC coprecipitated a wider array of trace elements than ammoniumpyrrolidinedithiocarbamate (APDC), another commonly used coprecipitate.
Naeemullah; Kazi, Tasneem G; Shah, Faheem; Afridi, Hassan I; Baig, Jameel Ahmed; Soomro, Abdul Sattar
2013-01-01
A simple method for the preconcentration of cadmium (Cd) and nickel (Ni) in drinking and wastewater samples was developed. Cloud point extraction has been used for the preconcentration of both metals, after formation of complexes with 8-hydroxyquinoline (8-HQ) and extraction with the surfactant octylphenoxypolyethoxyethanol (Triton X-114). Dilution of the surfactant-rich phase with acidified ethanol was performed after phase separation, and the Cd and Ni contents were measured by flame atomic absorption spectrometry. The experimental variables, such as pH, amounts of reagents (8-HQ and Triton X-114), temperature, incubation time, and sample volume, were optimized. After optimization of the complexation and extraction conditions, enhancement factors of 80 and 61, with LOD values of 0.22 and 0.52 microg/L, were obtained for Cd and Ni, respectively. The proposed method was applied satisfactorily for the determination of both elements in drinking and wastewater samples.
Feng, Zufei; Lu, Yan; Zhao, Yingjuan; Ye, Helin
2017-11-02
On the basis of magnetic molecularly imprinted polymer (MMIP) solid-phase extraction coupled with high performance liquid chromatography, we established a new method for the determination of the 4-methylimidazole (4-MEI) in soy sauce. Scanning electron microscopy (SEM), Fourier transform infrared (FT-IR), X-ray diffraction (XRD) and vibrating sample magnetometer (VSM) were used to characterize the synthesized MMIPs. To evaluate the polymers, batch rebinding experiments were carried out. The binding strength and capacity were determined from the derived Freundlich isotherm (FI) equation. The selective recognition capability of MMIPs was investigated with a reference compound and a structurally similar compound. As a selective pre-concentration sorbents for 4-methylimidazole in soy sauce, the MMIPs showed a satisfied recoveries rate of spiked samples, ranged from 97% to 105%. As a result, the prepared MMIPs could be applied to selectively pre-concentrate and determine 4-methylimidazole in soy sauce samples.
Ram-air sample collection device for a chemical warfare agent sensor
Megerle, Clifford A.; Adkins, Douglas R.; Frye-Mason, Gregory C.
2002-01-01
In a surface acoustic wave sensor mounted within a body, the sensor having a surface acoustic wave array detector and a micro-fabricated sample preconcentrator exposed on a surface of the body, an apparatus for collecting air for the sensor, comprising a housing operatively arranged to mount atop the body, the housing including a multi-stage channel having an inlet and an outlet, the channel having a first stage having a first height and width proximate the inlet, a second stage having a second lower height and width proximate the micro-fabricated sample preconcentrator, a third stage having a still lower third height and width proximate the surface acoustic wave array detector, and a fourth stage having a fourth height and width proximate the outlet, where the fourth height and width are substantially the same as the first height and width.
El Mhammedi, M A; Achak, M; Bakasse, M; Chtaini, A
2009-08-01
This paper reports on the use of platinum electrode modified with kaolin (K/Pt) and square wave voltammetry for analytical detection of trace lead(II) in pure water, orange and apple samples. The electroanalytical procedure for determination of the Pb(II) comprises two steps: the chemical accumulation of the analyte under open-circuit conditions followed by the electrochemical detection of the preconcentrated species using square wave voltammetry. The analytical performances of the extraction method has been explored by studying the incubating time, and effect of interferences due to other ions. During the preconcentration step, Pb(II) was accumulated on the surface of the kaolin. The observed detection and quantification limits in pure water were 3.6x10(-9)molL(-1) and 1.2x10(-8)molL(-1), respectively. The precision of the method was also determined; the results was 2.35% (n=5).
Yang, Rui; Pagaduan, Jayson V; Yu, Ming; Woolley, Adam T
2015-01-01
Microfluidic systems with monolithic columns have been developed for preconcentration and on-chip labeling of model proteins. Monoliths were prepared in microchannels by photopolymerization, and their properties were optimized by varying the composition and concentration of the monomers to improve flow and extraction. On-chip labeling of proteins was achieved by driving solutions through the monolith by use of voltage then incubating fluorescent dye with protein retained on the monolith. Subsequently, the labeled proteins were eluted, by applying voltages to reservoirs on the microdevice, and then detected, by monitoring laser-induced fluorescence. Monoliths prepared from octyl methacrylate combine the best protein retention with the possibility of separate elution of unattached fluorescent label with 50% acetonitrile. Finally, automated on-chip extraction and fluorescence labeling of a model protein were successfully demonstrated. This method involves facile sample pretreatment, and therefore has potential for production of integrated bioanalysis microchips.
Toward in situ monitoring of water contamination by nitroenergetic compounds.
Johnson, Brandy J; Leska, Iwona A; Medina, Alejandro; Dyson, Norris F; Nasir, Mansoor; Melde, Brian J; Taft, Jenna R; Charles, Paul T
2012-11-06
We have previously described the application of novel porous organosilicate materials to the preconcentration of nitroenergetic targets from aqueous solution prior to HPLC analysis. The performance of the sorbents and the advantages of these types of materials over commercially available solid phase extraction sorbents have been demonstrated. Here, the development of systems for application of those sorbents to in situ monitoring is described. Considerations such as column pressure, particulate filtration, and component durability are discussed. The diameter of selected column housings, the sorbent bed depth, and the frits utilized significantly impact the utility of the sorbent columns in the prototype system. The impact of and necessity for improvements in the morphological characteristics of the sorbents as they relate to reduction in column pressure are detailed. The results of experiments utilizing a prototype system are presented. Data demonstrating feasibility for use of the sorbents in preconcentration prior to ion mobility spectrometry is also presented.
Porous silicon structures with high surface area/specific pore size
Northrup, M.A.; Yu, C.M.; Raley, N.F.
1999-03-16
Fabrication and use of porous silicon structures to increase surface area of heated reaction chambers, electrophoresis devices, and thermopneumatic sensor-actuators, chemical preconcentrates, and filtering or control flow devices. In particular, such high surface area or specific pore size porous silicon structures will be useful in significantly augmenting the adsorption, vaporization, desorption, condensation and flow of liquids and gases in applications that use such processes on a miniature scale. Examples that will benefit from a high surface area, porous silicon structure include sample preconcentrators that are designed to adsorb and subsequently desorb specific chemical species from a sample background; chemical reaction chambers with enhanced surface reaction rates; and sensor-actuator chamber devices with increased pressure for thermopneumatic actuation of integrated membranes. Examples that benefit from specific pore sized porous silicon are chemical/biological filters and thermally-activated flow devices with active or adjacent surfaces such as electrodes or heaters. 9 figs.
Sahmetlioglu, Ertugrul; Yilmaz, Erkan; Aktas, Ece; Soylak, Mustafa
2014-02-01
A multi-walled carbon nanotubes-polypyrrole conducting polymer nanocomposite has been synthesized, characterized and used for the separation and preconcentration of lead at trace levels in water samples prior to its flame atomic absorption spectrometric detection. The analytical parameters like pH, sample volume, eluent, sample flow rate that were affected the retentions of lead(II) on the new nanocomposite were optimized. Matrix effects were also investigated. Limit of detection and preconcentration factors were 1.1 µg L(-1) and 200, respectively. The adsorption capacity of the nanocomposite was 25.0mg lead(II) per gram composite. The validation of the method was checked by using SPS-WW2 Waste water Level 2 certified reference material. The method was applied to the determination of lead in water samples with satisfactory results. © 2013 Elsevier B.V. All rights reserved.
Process for separation and preconcentration of radium from water
Dietz, Mark; Horwitz, E. Philip; Chiarizia, Renato; Bartsch, Richard A.
1999-01-01
A process for preconcentrating and separating radium from a contaminated solution containing at least water and radium includes the steps of adding a quantity of a water-soluble macrocyclic polyether to the contaminated solution to form a combined solution. An acid is added to the combined solution to form an acidic combined solution having an ›H.sup.+ ! concentration of about 0.5M. The acidic combined solution is contacted with a sulfonic acid-based strong acid cation exchange medium or a organophilic sulfonic acid medium having a plurality of binding sites thereon to bind the radium thereto and to form a radium-depleted solution. The radium-depleted solution is separated from the strong acid cation exchange medium or organophilic sulfonic acid medium. The radium remaining bound to the exchange medium or organophilic reagent is then stripped from the exchange medium or organophilic medium and the activity of the radium is measured.
Process for forming a porous silicon member in a crystalline silicon member
Northrup, M. Allen; Yu, Conrad M.; Raley, Norman F.
1999-01-01
Fabrication and use of porous silicon structures to increase surface area of heated reaction chambers, electrophoresis devices, and thermopneumatic sensor-actuators, chemical preconcentrates, and filtering or control flow devices. In particular, such high surface area or specific pore size porous silicon structures will be useful in significantly augmenting the adsorption, vaporization, desorption, condensation and flow of liquids and gasses in applications that use such processes on a miniature scale. Examples that will benefit from a high surface area, porous silicon structure include sample preconcentrators that are designed to adsorb and subsequently desorb specific chemical species from a sample background; chemical reaction chambers with enhanced surface reaction rates; and sensor-actuator chamber devices with increased pressure for thermopneumatic actuation of integrated membranes. Examples that benefit from specific pore sized porous silicon are chemical/biological filters and thermally-activated flow devices with active or adjacent surfaces such as electrodes or heaters.
Porous silicon structures with high surface area/specific pore size
Northrup, M. Allen; Yu, Conrad M.; Raley, Norman F.
1999-01-01
Fabrication and use of porous silicon structures to increase surface area of heated reaction chambers, electrophoresis devices, and thermopneumatic sensor-actuators, chemical preconcentrates, and filtering or control flow devices. In particular, such high surface area or specific pore size porous silicon structures will be useful in significantly augmenting the adsorption, vaporization, desorption, condensation and flow of liquids and gasses in applications that use such processes on a miniature scale. Examples that will benefit from a high surface area, porous silicon structure include sample preconcentrators that are designed to adsorb and subsequently desorb specific chemical species from a sample background; chemical reaction chambers with enhanced surface reaction rates; and sensor-actuator chamber devices with increased pressure for thermopneumatic actuation of integrated membranes. Examples that benefit from specific pore sized porous silicon are chemical/biological filters and thermally-activated flow devices with active or adjacent surfaces such as electrodes or heaters.
Liu, Yongjian; Mou, Shifen; Heberling, Shawn
2002-05-17
A simple sample preconcentration technique employing microwave-based evaporation for the determination of trace level bromate and perchlorate in drinking water with ion chromatography is presented. With a hydrophilic anion-exchange column and a sodium hydroxide eluent in linear gradient, bromate and perchlorate can be determined in one injection within 35 min. Prior to ion chromatographic analysis, the drinking water sample was treated with an OnGuard-Ag cartridge to remove the superfluous chloride and concentrated 20-fold using a PTFE beaker in a domestic microwave oven for 15 min. The recoveries of the anions ranged from 94.6% for NO2- to 105.2% for F-. The detection limits for bromate, perchlorate, iodate and chlorate were 0.1, 0.2, 0.1 and 0.2 microg/l, respectively. The developed method is applicable for the quantitation of bromate and perchlorate in drinking water samples.
Soylak, Mustafa; Unsal, Yunus Emre
2011-10-01
A preconcentration-separation procedure has been established based on solid-phase extraction of Fe(III) and Pb(II) on bucky tubes (BTs) disc. Fe(III) and Pb(II) ions were quantitatively recovered at pH 6. The influences of the analytical parameters like sample volume, flow rates on the recoveries of analytes on BT disc were investigated. The effects of co-existing ions on the recoveries were also studied. The detection limits for iron and lead were found 1.6 and 4.9 μg L⁻¹, respectively. The validation of the presented method was checked by the analysis of TMDA-51.3 fortified water certified reference material. The presented procedure was successfully applied to the separation-preconcentration and determination of iron and lead content of some natural water and herbal plant samples from Kayseri, Turkey.
Moghadam Zadeh, Hamid Reza; Ahmadvand, Parvaneh; Behbahani, Ali; Amini, Mostafa M; Sayar, Omid
2015-01-01
Graphene oxide nano-sheet was modified with dithizone as a novel sorbent for selective pre-concentration and determination of Cd(II) and Pb(II) in food. The sorbent was characterised by various analytical methods and the effective parameters for Cd(II) and Pb(II) adsorption were optimised during this work. The high adsorption capacity and selectivity of this sorbent makes the method capable of fast determinations of the Cd(II) and Pb(II) content in complicated matrices even at μg l(-1) levels using commonly available instrumentation. The precision of this method was < 1.9% from 10 duplicate determinations and its accuracy verified using standard reference materials. Finally, this method was applied to the determination of Cd(II) and Pb(II) ions in common food samples and satisfactory results were obtained.
Process for separation and preconcentration of radium from water
Dietz, M.; Horwitz, E.P.; Chiarizia, R.; Bartsch, R.A.
1999-01-26
A process for preconcentrating and separating radium from a contaminated solution containing at least water and radium includes the steps of adding a quantity of a water-soluble macrocyclic polyether to the contaminated solution to form a combined solution. An acid is added to the combined solution to form an acidic combined solution having an [H{sup +}] concentration of about 0.5M. The acidic combined solution is contacted with a sulfonic acid-based strong acid cation exchange medium or a organophilic sulfonic acid medium having a plurality of binding sites thereon to bind the radium thereto and to form a radium-depleted solution. The radium-depleted solution is separated from the strong acid cation exchange medium or organophilic sulfonic acid medium. The radium remaining bound to the exchange medium or organophilic reagent is then stripped from the exchange medium or organophilic medium and the activity of the radium is measured. 24 figs.
Takeuchi, Masaki; Tsunoda, Hiromichi; Tanaka, Hideji; Shiramizu, Yoshimi
2011-01-01
This paper describes the performance of our automated acidic (CH(3)COOH, HCOOH, HCl, HNO(2), SO(2), and HNO(3)) gases monitor utilizing a parallel-plate wet denuder (PPWD). The PPWD quantitatively collects gaseous contaminants at a high sample flow rate (∼8 dm(3) min(-1)) compared to the conventional methods used in a clean room. Rapid response to any variability in the sample concentration enables near-real-time monitoring. In the developed monitor, the analyte collected with the PPWD is pumped into one of two preconcentration columns for 15 min, and determined by means of ion chromatography. While one preconcentration column is used for chromatographic separation, the other is used for loading the sample solution. The system allows continuous monitoring of the common acidic gases in an advanced semiconductor manufacturing clean room. 2011 © The Japan Society for Analytical Chemistry
NASA Astrophysics Data System (ADS)
Son, Seok Young; Lee, Hyomin; Kim, Sung Jae
2017-12-01
Recently, novel biomolecules separation and detection methods based on ion concentration polarization (ICP) phenomena have been extensively researched due to its high amplification ratio and high-speed accumulation. Despite of these bright advances, the fabrication of conventional ICP devices still have complicated and times-consuming tasks. As an alternative platform, a paper have been recently used for the identical ICP operations. In this work, we demonstrated the selective preconcentration of a muc1 gene fragment as human breast cancer marker and a lamp-2 gene fragment as the cause of Danon disease in paper-based ICP devices. As a result, these two DNA fragments were successfully concentrated up to 60 fold at different location in a single paper-channel. The device would be a promising platform for point-of-care device due to an economic fabrication, the easy extraction of concentrated sample and an easy disposability.
Quantification of trace metals in water using complexation and filter concentration.
Dolgin, Bella; Bulatov, Valery; Japarov, Julia; Elish, Eyal; Edri, Elad; Schechter, Israel
2010-06-15
Various metals undergo complexation with organic reagents, resulting in colored products. In practice, their molar absorptivities allow for quantification in the ppm range. However, a proper pre-concentration of the colored complex on paper filter lowers the quantification limit to the low ppb range. In this study, several pre-concentration techniques have been examined and compared: filtering the already complexed mixture, complexation on filter, and dipping of dye-covered filter in solution. The best quantification has been based on the ratio of filter reflectance at a certain wavelength to that at zero metal concentration. The studied complex formations (Ni ions with TAN and Cd ions with PAN) involve production of nanoparticle suspensions, which are associated with complicated kinetics. The kinetics of the complexation of Ni ions with TAN has been investigated and optimum timing could be found. Kinetic optimization in regard to some interferences has also been suggested.
Design of monitoring system for mail-sorting based on the Profibus S7 series PLC
NASA Astrophysics Data System (ADS)
Zhang, W.; Jia, S. H.; Wang, Y. H.; Liu, H.; Tang, G. C.
2017-01-01
With the rapid development of the postal express, the workload of mail sorting is increasing, but the automatic technology of mail sorting is not mature enough. In view of this, the system uses Siemens S7-300 PLC as the main station controller, PLC of Siemens S7-200/400 is from the station controller, through the man-machine interface configuration software MCGS, PROFIBUS-DP communication, RFID technology and mechanical sorting hand achieve mail classification sorting monitoring. Among them, distinguish mail-sorting by scanning RFID posted in the mail electronic bar code (fixed code), the system uses the corresponding controller on the acquisition of information processing, the processed information transmit to the sorting manipulator by PROFIBUS-DP. The system can realize accurate and efficient mail sorting, which will promote the development of mail sorting technology.
Revisiting the role of durable polymers in cardiovascular devices.
Mori, Hiroyoshi; Otsuka, Fumiyuki; Gupta, Anuj; Jinnouchi, Hiroyuki; Torii, Sho; Harari, Emanuel; Virmani, Renu; Finn, Aloke V
2017-11-01
Polymers are an essential component of drug-eluting stents (DES) used to control drug release but remain the most controversial component of DES technology. There are two types of polymers employed in DES: durable polymer based DES (DP-DES) and biodegradable polymer DES (BP-DES). First-generation DES were exclusively composed of DP and demonstrated increased rates of late stent failure due in part to poor polymer biocompatibility. Newer generations DES use more biocompatible durable polymers or biodegradable polymers. Areas covered: We will cover issues identified with 1st-generation DP-DES, areas of success and failure in 2nd-generation DP-DES and examine the promise and shortcomings of BP-DES. Briefly, fluorinated polymers used in 2nd-generation DP-DES have excellent anti-thrombogenicity and better biocompatibility than 1st-generation DES polymers. However, these devices lead to persistent drug exposure to the endothelium which impairs endothelial function and predisposes towards neoatherosclerosis. Meanwhile, BP-DES has shortened the duration of drug exposure which might be beneficial for endothelial functional recovery leading to less neoatherosclerosis. However, it remains uncertain whether the long-term biocompatibility of bare metal surfaces is better than that of polymer-coated metals. Expert commentary: Each technology has distinct advantages, which can be optimized depending upon the particular characteristics of the patient being treated.
Study of 0.9PMN 0.1PT Dielectric Behaviour in Relation to the Nanostructure
NASA Astrophysics Data System (ADS)
Lattard, E.; Lejeune, M.; Imhoff, D.; Guinebretière, R.; Elissalde, C.; Abelard, P.
1997-06-01
(1 - x)PbMg{1/3}Nb{2/3}O{3-x}PbTiO3 ceramics with x = 0, 0.1 were prepared with a 12 mol% MgO excess to obtain dense and perovskite phase materials after sintering. The dielectric characterization has revealed that a local polarization appears at a T_d temperature largely above the temperature of the maximum of permittivity (T_m, respectively -13 ^{circ}C and +36 ^{circ}C for x = 0 and 0.1). This phenomena is consistent with the nucleation of polar clusters. Moreover, a dielectric relaxation is observed for 0.9PMN-0.1PT-0.12MgO, in a large frequency range (100 Hz 1 GHz), which corresponds to a multi-Debye process with broadening of the relaxation time distribution as the temperature decreases. This suggests a nucleation and growth mechanism of polar clusters with decreasing temperature, which can result from the successive transitions of different compositions. This hypothesis was confirmed by the identification of large chemical heterogeneities on a nanometric scale by TEM using two spectroscopy techniques (EDXS and EELS), because of the association of low and high atomic number elements in the materials, different types of equipment and also the simulation of the patterns with standards. In fact, these quantitative analyses have revealed large fluctuations of the local composition around the nominal one: lead and magnesium deficient areas enriched in niobium coexist with nanodomains largely enriched in lead and slightly in magnesium, which the size depends on the titanium content. The origin of these heterogeneities in correlation with the reactions sequences during calcination and sintering is discussed: in particular the addition of titanium contributes, by stabilizing the perovskite phase, to limit the diffusion of lead oxide, which consequently increases the homogeneity of the ceramics. Due to such heterogeneities, the material remains mainly paraelectric up to very low temperatures. This effect can be balanced by the application of a high electric field which induces the growth of the polar clusters by displacement of their interface with the paraelectric matrix and orientation of their polarization in the direction of the electric field which can lead to a macroscopic ferroelectric transition in specific conditions of temperature and electric field intensity. These different mechanisms relax in a frequency range which depends on the temperature and on the amplitude of the electric field. Des céramiques polycristallines du type (1 - x)PbMg{1/3}Nb{2/3}O{3-x}PbTiO3 avec x = 0 et 10 % molaires ont été élaborées avec un excès de MgO (12 % molaires) permettant d'obtenir des matériaux denses de structure pérovskite. Des mesures de permittivité diélectrique ont montré qu'une polarisation locale apparaît dans ces matériaux à des températures (T_d) largement supérieures à celles correspondant au maximum de permittivité (T_m respectivement égale à -13 ^{circ}C et +36 ^{circ}C pour x = 0 et 0,10). Ceci est cohérent avec la formation de nanodomaines polaires au sein du matériau. Par ailleurs, une étude des caractéristiques diélectriques sur une large gamme de fréquence (100 Hz 10^9 Hz) fait apparaître une relaxation de type multi-Debye, la distribution des temps de relaxation correspondants s'élargissant vers les basses fréquences lorsque la température diminue. Ce phénomène peut être relié à un processus de nucléation-croissance des clusters polaires sur une large gamme de température, résultant des fluctuations de composition chimique au sein du matériau identifiées à l'échelle nanométrique par deux techniques de spectroscopie (EDX et EELS) en microscopie électronique en transmission. En effet, ces analyses ont mis en évidence de larges fluctuations de composition autour de la composition nominale du matériau : des zones appauvries en plomb et en magnésium et enrichies en niobium coexistent avec des nanodomaines fortement enrichis en plomb et légérement en magnésium dont la taille varie avec la teneur en titane. Nous avons cherché à corréler ces hétérogénéités aux mécanismes réactionnels intervenant au cours des traitements thermiques nécessaires à l'élaboration de ces céramiques, en particulier, il apparaît que le titane en stabilisant la phase pérovskite contribue à limiter la diffusion de l'oxyde de plomb et à augmenter ainsi le degré d'homogénéité du matériau. Du fait de ces fortes hétérogénéités chimiques, le matériau reste globalement paraélectrique jusqu'à basse température mais le mécanisme de nucléation-croissance est accéléré par application d'un champ électrique de forte amplitude de telle sorte qu'en dessous d'une température T_t le matériau devient majoritairement ferroélectrique. Ces mécanismes correspondant à un déplacement de l'interface des domaines polaires avec la matrice paraélectrique et à une orientation des vecteurs polarisation dans la direction du champ électrique relaxent dans une gamme de fréquence fonction de la température et de l'amplitude du champ électrique.
Park, Kwangjin; Botelho, Salomé Calado; Hong, Joonki; Österberg, Marie; Kim, Hyun
2013-01-01
Mitochondrial inner membrane proteins that carry an N-terminal presequence are sorted by one of two pathways: stop transfer or conservative sorting. However, the sorting pathway is known for only a small number of proteins, in part due to the lack of robust experimental tools with which to study. Here we present an approach that facilitates determination of inner membrane protein sorting pathways in vivo by fusing a mitochondrial inner membrane protein to the C-terminal part of Mgm1p containing the rhomboid cleavage region. We validated the Mgm1 fusion approach using a set of proteins for which the sorting pathway is known, and determined sorting pathways of inner membrane proteins for which the sorting mode was previously uncharacterized. For Sdh4p, a multispanning membrane protein, our results suggest that both conservative sorting and stop transfer mechanisms are required for insertion. Furthermore, the sorting process of Mgm1 fusion proteins was analyzed under different growth conditions and yeast mutant strains that were defective in the import motor or the m-AAA protease function. Our results show that the sorting of mitochondrial proteins carrying moderately hydrophobic transmembrane segments is sensitive to cellular conditions, implying that mitochondrial import and membrane sorting in the physiological environment may be dynamically tuned. PMID:23184936
Seminal plasma affects sperm sex sorting in boars.
Alkmin, Diego V; Parrilla, Inmaculada; Tarantini, Tatiana; Del Olmo, David; Vazquez, Juan M; Martinez, Emilio A; Roca, Jordi
2016-04-01
Two experiments were conducted in boar semen samples to evaluate how both holding time (24h) and the presence of seminal plasma (SP) before sorting affect sperm sortability and the ability of sex-sorted spermatozoa to tolerate liquid storage. Whole ejaculate samples were divided into three aliquots immediately after collection: one was diluted (1:1, v/v) in Beltsville thawing solution (BTS; 50% SP); the SP of the other two aliquots was removed and the sperm pellets were diluted with BTS + 10% of their own SP (10% SP) or BTS alone (0% SP). The three aliquots of each ejaculate were divided into two portions, one that was processed immediately for sorting and a second that was sorted after 24h storage at 15-17°C. In the first experiment, the ability to exhibit well-defined X- and Y-chromosome-bearing sperm peaks (split) in the cytometry histogram and the subsequent sorting efficiency were assessed (20 ejaculates). In contrast with holding time, the SP proportion influenced the parameters examined, as evidenced by the higher number of ejaculates exhibiting split and better sorting efficiency (P<0.05) in semen samples with 0-10% SP compared with those with 50% SP. In a second experiment, the quality (viability, total and progressive motility) and functionality (plasma membrane fluidity and intracellular generation of reactive oxygen species) of sex-sorted spermatozoa were evaluated after 0, 72 and 120h storage at 15-17°C (10 ejaculates). Holding time and SP proportion did not influence the quality or functionality of stored sex-sorted spermatozoa. In conclusion, a holding time as long as 24h before sorting did not negatively affect sex sorting efficiency or the ability of sorted boar spermatozoa to tolerate long-term liquid storage. A high proportion of SP (50%) in the semen samples before sorting reduced the number of ejaculates to be sorted and negatively influenced the sorting efficiency, but did not affect the ability of sex-sorted spermatozoa to tolerate liquid storage.
NASA Astrophysics Data System (ADS)
Mejdi, Abderrazak
Les fuselages des avions sont generalement en aluminium ou en composite renforces par des raidisseurs longitudinaux (lisses) et transversaux (cadres). Les raidisseurs peuvent etre metalliques ou en composite. Durant leurs differentes phases de vol, les structures d'avions sont soumises a des excitations aeriennes (couche limite turbulente : TBL, champs diffus : DAF) sur la peau exterieure dont l'energie acoustique produite se transmet a l'interieur de la cabine. Les moteurs, montes sur la structure, produisent une excitation solidienne significative. Ce projet a pour objectifs de developper et de mettre en place des strategies de modelisations des fuselages d'avions soumises a des excitations aeriennes et solidiennes. Tous d'abord, une mise a jour des modeles existants de la TBL apparait dans le deuxieme chapitre afin de mieux les classer. Les proprietes de la reponse vibro-acoustique des structures planes finies et infinies sont analysees. Dans le troisieme chapitre, les hypotheses sur lesquelles sont bases les modeles existants concernant les structures metalliques orthogonalement raidies soumises a des excitations mecaniques, DAF et TBL sont reexamines en premier lieu. Ensuite, une modelisation fine et fiable de ces structures est developpee. Le modele est valide numeriquement a l'aide des methodes des elements finis (FEM) et de frontiere (BEM). Des tests de validations experimentales sont realises sur des panneaux d'avions fournis par des societes aeronautiques. Au quatrieme chapitre, une extension vers les structures composites renforcees par des raidisseurs aussi en composites et de formes complexes est etablie. Un modele analytique simple est egalement implemente et valide numeriquement. Au cinquieme chapitre, la modelisation des structures raidies periodiques en composites est beaucoup plus raffinee par la prise en compte des effets de couplage des deplacements planes et transversaux. L'effet de taille des structures finies periodiques est egalement pris en compte. Les modeles developpes ont permis de conduire plusieurs etudes parametriques sur les proprietes vibro-acoustiques des structures d'avions facilitant ainsi la tache des concepteurs. Dans le cadre de cette these, un article a ete publie dans le Journal of Sound and Vibration et trois autres soumis, respectivement aux Journal of Acoustical Society of America, International Journal of Solid Mechanics et au Journal of Sound and Vibration Mots cles : structures raidies, composites, vibro-acoustique, perte par transmission.
Cochrane, Bonnie S; Hagins, Mitch; King, John A; Picciano, Gino; McCafferty, Maureen M; Nelson, Brian
2015-11-01
Au Canada, l'amélioration de l'expérience des patients est devenue une priorité des politiques de santé. Le perfectionnement et la normalisation des outils et systèmes pour surveiller les mesures de l'expérience des patients augmentent, tandis que la tendance vers une plus grande reddition de compte sur des améliorations durables et abordables se confirme. Pour de nombreux professionnels de la santé, ce phénomène fait foi d'un intérêt renouvelé pour les besoins et priorités fondamentaux des patients, après des décennies où les changements structurels et technologiques ont dominé les programmes de santé. Pour les leaders en santé canadiens, l'amélioration de l'expérience des patients comporte actuellement de grands défis et de belles possibilités. À cet égard, l'expérience des organisations partenaires du groupe Studer au Canada est à la fois pertinente et instructive. Ces organisations ont adopté un modèle, du nom de Evidence-Based Leadership (EBL, ou leadership fondé sur des données probantes), qui favorise et soutient l'harmonisation de l'ensemble des activités et des comportements, conformément à des objectifs organisationnels précis, y compris des améliorations mesurables de l'expérience des patients. Le présent article expose des études de cas d'organisations qui ont adopté l'EBL. Ces organisations ont réalisé des progrès rapides en matière d'indicateurs de l'expérience des patients, ainsi que dans des secteurs essentiels comme les résultats cliniques, la sécurité et le rendement financier. Les données émergentes sur les facteurs et processus qui sous-tendent ces améliorations sont également abordées. © 2015 Collège canadien des leaders en santé
Stochastic Model of Vesicular Sorting in Cellular Organelles
NASA Astrophysics Data System (ADS)
Vagne, Quentin; Sens, Pierre
2018-02-01
The proper sorting of membrane components by regulated exchange between cellular organelles is crucial to intracellular organization. This process relies on the budding and fusion of transport vesicles, and should be strongly influenced by stochastic fluctuations, considering the relatively small size of many organelles. We identify the perfect sorting of two membrane components initially mixed in a single compartment as a first passage process, and we show that the mean sorting time exhibits two distinct regimes as a function of the ratio of vesicle fusion to budding rates. Low ratio values lead to fast sorting but result in a broad size distribution of sorted compartments dominated by small entities. High ratio values result in two well-defined sorted compartments but sorting is exponentially slow. Our results suggest an optimal balance between vesicle budding and fusion for the rapid and efficient sorting of membrane components and highlight the importance of stochastic effects for the steady-state organization of intracellular compartments.
Identification and genetic analysis of cancer cells with PCR-activated cell sorting
Eastburn, Dennis J.; Sciambi, Adam; Abate, Adam R.
2014-01-01
Cell sorting is a central tool in life science research for analyzing cellular heterogeneity or enriching rare cells out of large populations. Although methods like FACS and FISH-FC can characterize and isolate cells from heterogeneous populations, they are limited by their reliance on antibodies, or the requirement to chemically fix cells. We introduce a new cell sorting technology that robustly sorts based on sequence-specific analysis of cellular nucleic acids. Our approach, PCR-activated cell sorting (PACS), uses TaqMan PCR to detect nucleic acids within single cells and trigger their sorting. With this method, we identified and sorted prostate cancer cells from a heterogeneous population by performing >132 000 simultaneous single-cell TaqMan RT-PCR reactions targeting vimentin mRNA. Following vimentin-positive droplet sorting and downstream analysis of recovered nucleic acids, we found that cancer-specific genomes and transcripts were significantly enriched. Additionally, we demonstrate that PACS can be used to sort and enrich cells via TaqMan PCR reactions targeting single-copy genomic DNA. PACS provides a general new technical capability that expands the application space of cell sorting by enabling sorting based on cellular information not amenable to existing approaches. PMID:25030902
Felix, Caio S A; Silva, Darllen G; Andrade, Heloysa M C; Riatto, Valeria B; Victor, Mauricio M; Ferreira, Sergio L C
2018-07-01
This work proposes an on-line preconcentration system using ion-imprinted polymer (IIP) for determination of bismuth in seawater employing atomic fluorescence spectrometry (AFS). The polymer was synthesized using 2- (5-bromo-2-pyridylazo) -5-diethylaminophenol (Br-PADAP) for complex formation, ethylene glycol dimethacrylate (EGDMA), cross-linking reagent and methacrylic acid (AMA) reagents, used as the functional monomer, 2,2-azobisisobutyronitrile was used as the radical initiator. The polymer was characterized employing the Fourier transform infrared spectroscopy (FTIR) and scanning electron microscopy (SEM). The determination of bismuth was performed employing hydride generation atomic fluorescence spectrometry (HG AFS) and the experimental conditions were optimized using a Box Behnken design involving the factors sample pH, eluent concentration and sodium tetrahydroborate concentration. So, using the optimized conditions the system allows the determination of bismuth with limits of detection and quantification of 26 and 88 ng L -1 , a preconcentration factor of 19.8. All these parameters were determined using a sample volume of 25 mL. The precision expressed as relative standard deviation (RSD%) was 3.7% for a bismuth(III) solution of concentration 0.25 µg L -1 . The system proposed was applied for the determination of bismuth in four seawater samples collected in Salvador City, Bahia State, Brazil. The concentrations obtained varied from 0.38 to 0.45 μg L -1 . The accuracy was evaluated by addition/recovery test, and the recoveries found varied from 92% to 101%. Copyright © 2018 Elsevier B.V. All rights reserved.
Behbahani, Mohammad; Bagheri, Akbar; Taghizadeh, Mohsen; Salarian, Mani; Sadeghi, Omid; Adlnasab, Laleh; Jalali, Kobra
2013-06-01
This paper describes the preparation of new Pb(II)-imprinted polymeric particles using 2-vinylpyridine as a functional monomer, ethylene glycol dimethacrylate as the cross-linker, 2,2'- azobisisobutyronitrile as the initiator, diphenylcarbazone as the ligand, acetonitril as the solvent, and Pb(NO(3))(2) as the template ion, through bulk polymerisation technique. The imprinted lead ions were removed from the polymeric matrix using 5 mL of HCl (2 mol.L(-1)) as the eluting solvent. The lead ion concentration was determined by flame atomic absorption spectrometry. Optimum pH for maximum sorption was obtained at 6.0. Sorption and desorption of Pb(II) ions on the IIP particles were quite fast and achieved fully over 5 min. In the proposed method, the maximum sorbent capacity of the ion-imprinted polymer was calculated to be 75.4 mg g(-1). The preconcentration factor, relative standard deviation, and limit of detection of the method were found to be 245, 2.1%, and 0.42 ng mL(-1), respectively. The prepared ion-imprinted polymer particles have an increased selectivity toward Pb(II) ions over a range of competing metal ions with the same charge and similar ionic radius. This ion-imprinted polymer is an efficient solid phase for extraction and preconcentration of lead ions in complex matrixes. For proving that the proposed method is reliable, a wide range of food samples with different and complex matrixes was used. Copyright © 2012 Elsevier Ltd. All rights reserved.
Goudarzi, Nasser; Amirnavaee, Monavar; Arab Chamjangali, Mansour; Farsimadan, Sahar
2017-07-01
An improved microextraction method is proposed on the basis of ultrasound-assisted surfactant-enhanced emulsification and solidification of a floating organic droplet procedure combined with high performance liquid chromatography for the preconcentration and quantification of alprazolam (ALP) and chlordiazepoxide (CHL) present in a number of human serum samples. Several parameters affecting the extraction efficiency were investigated by the Plackett -Burman factorial design as the screening design. Then the response surface methodology based on the Box-Behnken design was used to optimize the effective parameters in the proposed procedure. The limits of detection for the proposed method were found to be 3.0 and 3.1 ng mL-1 for CHL and ALP, respectively. The calibration curves obtained for the method were linear in the ranges of 10.0-3,500.0 and 10.0-3,000.0 ng mL-1 for CHL and ALP, respectively, with a good determination coefficient. The recoveries of the drugs in the spiked human serum samples were above 93.0%. The developed method was successfully applied to the analysis of these studied drugs in human serum samples. The pre-treatment of the serum samples was performed using acetonitrile to remove the proteins. The proposed procedure was an accurate and reliable one for the determination and preconcentration of these drugs in blood samples. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Gopal, Judy; Wu, Hui-Fen; Lee, Chia-Hsun; Manikandan, Muthu
2012-01-21
Ants and humans coexist closely and for the most part happily. We consider ants to be harmless, small beings--we have no problem picking them out of our tea cups or sugar jars, throwing them away and continuing to consume the food. This paper is an eye-opener that these ants are not as harmless as they may seem. In particular, our relationship with those present in bacteria-rich environments (e.g. a microbiological lab) need to be reconsidered. From an analytical point of view we have applied the physical preconcentration coupled ZnO NPs assisted MALDI-MS (PP-MALDI-MS) as a novel and sensitive technique for detecting bacteria on the surface of a species of ant present in our laboratory. The preconcentration methods consist of simple techniques comprising of vortex combined with centrifugation or ultrasonication resulting in increasing sample concentration up to the MALDI-MS detection limit. ZnO NPs were used to further enhance the bacterial signals for culture free rapid analysis using MALDI-MS. The importance of a vortex-combined centrifugation approach, using a large number of samples (large number of ants) and decreasing the suspension volume and addition of sample to ZnO NPs (3.5g L(-1)) were found to be crucial prerequisites for increasing MALDI-MS detection of bacteria on ants. We were able to identify the pathogenic clinically important Staphylococcus aureus on the surface of the ants. The bacterial identification was validated using ClinPro 2.1.
Tu, Zhifeng; He, Qun; Chang, Xijun; Hu, Zheng; Gao, Ru; Zhang, Lina; Li, Zhenhua
2009-09-07
A novel method that utilizes 1-(2-formamidoethyl)-3-phenylurea-modified activated carbon (AC-1-(2-formamidoethyl)-3-phenylurea) as a solid-phase extractant has been developed for simultaneous preconcentration of trace Cr(III), Cu(II), Fe(III) and Pb(II) prior to the measurement by inductively coupled plasma atomic emission spectrometry (ICP-AES). Experimental conditions for effective adsorption of trace levels of Cr(III), Cu(II), Fe(III) and Pb(II) were optimized using batch and column procedures in detail. The optimum pH value for the separation of metal ions simultaneously on the new sorbent was 4. And the adsorbed metal ions could be completely eluted by using 2.0 mL 2.0 mol L(-1) HCl solution. Common coexisting ions did not interfere with the separation and determination of target metal ions. The maximum static adsorption capacity of the sorbent at optimum conditions was found to be 39.8, 39.9, 77.8 and 17.3 mg g(-1) for Cr(III), Cu(II), Fe(III) and Pb(II), respectively. The detection limits of the method were found to be 0.15, 0.41, 0.27 and 0.36 ng mL(-1) for Cr(III), Cu(II), Fe(III) and Pb(II), respectively. The relative standard deviation (RSD) of the method was lower than 4.0% (n=8). The method was successfully applied for the preconcentration of trace Cr(III), Cu(II), Fe(III) and Pb(II) in natural and certified samples with satisfactory results.
Risse, Fabian; Gedig, Erk T; Gutmann, Jochen S
2018-04-30
The carbodiimide-mediated amine coupling of protein ligands to sensor chips coated with anionic polycarboxylate hydrogels, such as carboxymethyl dextran, is the predominant covalent immobilization procedure utilized in optical biosensors, namely surface plasmon resonance (SPR) biosensors. Usually, electrostatic interactions at a slightly acidic pH and low ionic strength are employed to efficiently accumulate neutral and basic ligands on the chip surface, which are then covalently coupled by surface-bound active N-hydroxysuccinimide (NHS) esters. Unfortunately, this approach is not suitable for acidic proteins or other ligands with low isoelectric points (IEPs), such as nucleic acids, because the charge density of the polycarboxylates is greatly reduced at acidic pH or because electrostatic attraction cannot be achieved. To overcome these drawbacks, we have established a charge-reversal approach that allows the preconcentration of acidic proteins above their IEPs. A precisely controlled amount of tertiary amines is applied to reverse the previous anionic surface charge while maintaining carbodiimide compatibility with future protein immobilization. The mechanism of this reversed-charge immobilization approach was demonstrated employing protein A as a model protein and using attenuated total reflectance Fourier transform infrared spectroscopy, dynamic contact angle measurements, colorimetric quantification, and SPR analysis to characterize surface derivatization. Furthermore, even though it had previously proven impossible to preconcentrate DNA electrostatically and to covalently couple it to polyanionic chip surfaces, we demonstrated that our approach allowed DNA to be preconcentrated and immobilized in good yields. Graphical abstract Principle of the covalent immobilization of acidic ligands on reversed-charge zwitterionic sensor chip surfaces.
Kler, Pablo A; Huhn, Carolin
2014-11-01
Isotachophoresis (ITP) has long been used alone but also as a preconcentration technique for capillary electrophoresis (CE). Unfortunately, up to now, its application is restricted to relatively strong acids and bases as either the degree of (de)protonation is too low or the water dissociation is too high, evoking zone electrophoresis. With the comprehensive ITP analysis of all 20 proteinogenic amino acids as model analytes, we, here, show that non-aqueous ITP using dimethylsulfoxide as a solvent solves this ITP shortcoming. Dimethylsulfoxide changes the pH regime of analytes and electrolytes but, more importantly, strongly reduces the proton mobility by prohibiting hydrogen bonds and thus, the so-called Zundel-Eigen-Zundel electrical conduction mechanism of flipping hydrogen bonds. The effects are demonstrated in an electrolyte system with taurine or H(+) as terminator, and imidazole as leader together with strong acids such as oxalic and even trifluoroacetic acid as counterions, both impossible to use in aqueous solution. Mass spectrometric as well as capacitively coupled contactless conductivity detection (C(4)D) are used to follow the ITP processes. To demonstrate the preconcentration capabilities of ITP in a two-dimensional set-up, we, here, also demonstrate that our non-aqueous ITP method can be combined with capillary electrophoresis-mass spectrometry in a column-coupling system using a hybrid approach of capillaries coupled to a microfluidic interface. For this, C(4)D was optimized for on-chip detection with the electrodes aligned on top of a thin glass lid of the microfluidic chip.
Yavuz, Emre; Tokalıoğlu, Serife; Sahan, Halil; Patat, Saban
2014-10-01
In this study, a nano sponge Mn2O3 adsorbent was synthesized and was used for the first time. Various parameters affecting the recovery values of Pd(II) and Rh(III) were examined. The tolerance limits (≥ 90 %) for both Pd(II) and Rh(III) ions were found to be 75,000 mg L(-1) Na(I), 75,000 mg L(-1) K(I), 50,000 mg L(-1) Mg(II) and 50,000 mg L(-1) Ca(II). A 30s contact time was enough for both adsorption and elution. A preconcentration factor of 100 was obtained by using 100mg of the nano sponge Mn2O3. The reusability of the adsorbent was 120 times. Adsorption capacities for Pd(II) and Rh(III) were found to be 42 and 6.2 mg g(-1), respectively. The detection limits were 1.0 µg L(-1) for Pd(II) and 0.37 µg L(-1) for Rh(III) and the relative standard deviations (RSD, %) were found to be ≤ 2.5%. The method was validated by analyzing the standard reference material, SRM 2556 (Used Auto Catalyst Pellets) and spiked real samples. The optimized method was applied for the preconcentration of Pd(II) and Rh(III) ions in water (sea water and wastewater), rock, street sediment and catalytic converter samples. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Panetta, Robert James; Seed, Mike
2016-04-01
Stable isotope applications that call for preconcentration (i.e., greenhouse gas measurements, small carbonate samples, etc.) universally call for cryogenic fluids such as liquid nitrogen, dry ice slurries, or expensive external recirculation chillers. This adds significant complexity, first and foremost in the requirements to store and handle such dangerous materials. A second layer of complexity is the instrument itself - with mechanisms to physically move either coolant around the trap, or move a trap in or out of the coolant. Not to mention design requirements for hardware that can safely isolate the fluid from other sensitive areas. In an effort to simplify the isotopic analysis of gases requiring preconcentration, we have developed a new separation technology, UltiTrapTM (patent pending), which leverage's the proprietary Advanced Purge & Trap (APT) Technology employed in elemental analysers from Elementar Analysensysteme GmbH products. UltiTrapTM has been specially developed as a micro volume, dynamically heated GC separation column. The introduction of solid-state cooling technology enables sub-zero temperatures without cryogenics or refrigerants, eliminates all moving parts, and increases analytical longevity due to no boiling losses of coolant . This new technology makes it possible for the system to be deployed as both a focussing device and as a gas separation device. Initial data on synthetic gas mixtures (CO2/CH4/N2O in air), and real-world applications including long-term room air and a comparison between carbonated waters of different origins show excellent agreement with previous technologies.
Lu, Ping; Deng, Dayi; Ni, Xiaodan
2012-09-01
Multiwalled carbon nanotubes functionalized by oxidation of original multiwalled carbon nanotubes with NaClO were prepared and their application as solid phase extraction sorbent for 2,4-dichlorophenoxyacetic acid (2,4-D) was investigated systemically, and a new method was developed for the determination of trace 2,4-D in water samples based on extraction and preconcentration of 2,4-D with solid phase extraction columns packed with NaClO-treated multiwalled carbon nanotubes prior to its determination by HPLC. The optimum experimental parameters for preconcentration of 2,4-D, including the column activating conditions, the amount of the sorbent, pH of the sample, elution composition, and elution volume, were investigated. The results indicated 2,4-D could be quantitatively retained by 100 mg NaClO-treated multiwalled carbon nanotubes at pH 5, and then eluted completely with 10 mL 3:1 (v/v) methanol-ammonium acetate solution (0.3 mol/L). The detection limit of this method for 2,4-D was 0.15 μg/L, and the relative standard deviation was 2.3% for fortified tap water samples and 2.5% for fortified riverine water sample at the 10 μg/L level. The method was validated using fortified tap water and riverine water samples with known amount of 2,4-D at the 0.4, 10, and 30 μg/L levels, respectively. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Chávez-Moreno, C A; Guzmán-Mar, J L; Hinojosa-Reyes, L; Hernández-Ramírez, A; Ferrer, L; Cerdà, V
2012-07-01
Simultaneous determination of three herbicides (dicamba, 2,4-D, and atrazine) has been achieved by on-line solid-phase extraction (SPE) coupled to multisyringe chromatography (MSC) with UV detection. The preconcentration conditions were optimized; a preconcentration flow rate of 0.5 mL min(-1) and elution at 0.8 mL min(-1) were the optimum conditions. A C(18) (8 mm i.d.) membrane extraction disk conditioned with 0.3 mol L(-1) HCl in 0.5% MeOH was used. A 3-mL sample was preconcentrated, then eluted with 0.43 mL 40:60 water-MeOH. A C(18) monolithic column (25 mm × 4.6 mm) was used for chromatographic separation. Separation of the three compounds was achieved in 10 min by use of 0.01% aqueous acetic acid-MeOH (60:40) as mobile phase at a flow rate of 0.8 mL min(-1). The limits of detection (LOD) were 13, 57, and 22 μg L(-1) for dicamba, 2,4-D, and atrazine, respectively. The sampling frequency was three analyses per hour, and each analysis consumed only 7.3 mL solvent. The method was applied to spiked water samples, and recovery between 85 and 112% was obtained. Recovery was significantly better than in the conventional HPLC-UV method. These results indicated the reliability and accuracy of this flow-based method. This is the first time this family of herbicides has been simultaneously analyzed by on-line SPE-MSC using a monolithic column.
Horká, Marie; Karásek, Pavel; Roth, Michal; Šlais, Karel
2017-05-01
In this work, single-piece fused silica capillaries with two different internal diameter segments featuring different inner surface roughness were prepared by new etching technology with supercritical water and used for volume coupling electrophoresis. The concept of separation and online pre-concentration of analytes in high conductivity matrix is based on the online large-volume sample pre-concentration by the combination of transient isotachophoretic stacking and sweeping of charged proteins in micellar electrokinetic chromatography using non-ionogenic surfactant. The modified surface roughness step helped to the significant narrowing of the zones of examined analytes. The sweeping and separating steps were accomplished simultaneously by the use of phosphate buffer (pH 7) containing ethanol, non-ionogenic surfactant Brij 35, and polyethylene glycol (PEG 10000) after sample injection. Sample solution of a large volume (maximum 3.7 μL) dissolved in physiological saline solution was injected into the wider end of capillary with inlet inner diameter from 150, 185 or 218 μm. The calibration plots were linear (R 2 ∼ 0.9993) over a 0.060-1 μg/mL range for the proteins used, albumin and cytochrome c. The peak area RSDs from at least 20 independent measuremens were below 3.2%. This online pre-concentration technique produced a more than 196-fold increase in sensitivity, and it can be applied for detection of, e.g. the presence of albumin in urine (0.060 μg/mL). © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Es'haghi, Zarrin; Ebrahimi, Mahmoud; Hosseini, Mohammad-Saeid
2011-05-27
A novel design of solid phase microextraction fiber containing carbon nanotube reinforced sol-gel which was protected by polypropylene hollow fiber (HF-SPME) was developed for pre-concentration and determination of BTEX in environmental waste water and human hair samples. The method validation was included and satisfying results with high pre-concentration factors were obtained. In the present study orthogonal array experimental design (OAD) procedure with OA(16) (4(4)) matrix was applied to study the effect of four factors influencing the HF-SPME method efficiency: stirring speed, volume of adsorption organic solvent, extraction and desorption time of the sample solution, by which the effect of each factor was estimated using individual contributions as response functions in the screening process. Analysis of variance (ANOVA) was employed for estimating the main significant factors and their percentage contributions in extraction. Calibration curves were plotted using ten spiking levels of BTEX in the concentration ranges of 0.02-30,000ng/mL with correlation coefficients (r) 0.989-0.9991 for analytes. Under the optimized extraction conditions, the method showed good linearity (0.3-20,000ng/L), repeatability, low limits of detections (0.49-0.7ng/L) and excellent pre-concentration factors (185-1872). The best conditions which were estimated then applied for the analysis of BTEX compounds in the real samples. Copyright © 2011 Elsevier B.V. All rights reserved.
Analysis of Ethane and Diethylbenzene Bridged Sorbents
2017-12-13
Leska; P.T. Charles; B.J. Melde; J.R. Taft, "Electrochemical Detection with Preconcentration: Nitroenergetic Contaminants ," Chemosensors 2, 131...monitoring of contaminants in groundwater: Sorbent development; Naval Research Laboratory: 2013. Analysis of Ethane and Diethylbenzene Bridged Sorbents 7...
Montano, G A; Kraemer, D C; Love, C C; Robeck, T R; O'Brien, J K
2012-06-01
Artificial insemination (AI) with sex-sorted frozen-thawed spermatozoa has led to enhanced management of ex situ bottlenose dolphin populations. Extended distance of animals from the sorting facility can be overcome by the use of frozen-thawed, sorted and recryopreserved spermatozoa. Although one bottlenose dolphin calf had been born using sexed frozen-thawed spermatozoa derived from frozen semen, a critical evaluation of in vitro sperm quality is needed to justify the routine use of such samples in AI programs. Sperm motility parameters and plasma membrane integrity were influenced by stage of the sex-sorting process, sperm type (non-sorted and sorted) and freezing method (straw and directional) (P<0.05). After recryopreservation, sorted spermatozoa frozen with the directional freezing method maintained higher (P<0.05) motility parameters over a 24-h incubation period compared to spermatozoa frozen using straws. Quality of sperm DNA of non-sorted spermatozoa, as assessed by the sperm chromatin structure assay (SCSA), was high and remained unchanged throughout freeze-thawing and incubation processes. Though a possible interaction between Hoechst 33342 and the SCSA-derived acridine orange was observed in stained and sorted samples, the proportion of sex-sorted, recryopreserved spermatozoa exhibiting denatured DNA was low (6.6±4.1%) at 6 h after the second thawing step and remained unchanged (P>0.05) at 24 h. The viability of sorted spermatozoa was higher (P<0.05) than that of non-sorted spermatozoa across all time points after recryopreservation. Collective results indicate that bottlenose dolphin spermatozoa undergoing cryopreservation, sorting and recryopreservation are of adequate quality for use in AI.
Nizamani, Sooraj; Kazi, Tasneem G; Afridi, Hassan I
2018-01-01
An efficient preconcentration technique based on ultrasonic-assisted ionic liquid-based dual microextraction (UA-ILDµE) method has been developed to preconcentrate the lead (Pb +2 ) in ground and stored rain water. In the current proposed method, Pb +2 was complexed with a chelating agent (dithizone), whereas an ionic liquid (1-butyl-3-methylimidazolium hexafluorophosphate) was used for extraction purpose. The ultrasonic irradiation and electrical shaking system were applied to enhance the dispersion and extraction of Pb +2 complex in aqueous samples. For second phase, dual microextraction (DµE phase), the enriched Pb +2 complex in ionic liquid, extracted back into the acidic aqueous solution and finally determined by flame atomic absorption spectrometry. Some major analytical parameters that influenced the extraction efficiency of developed method, such as pH, concentration of ligand, volume of ionic liquid and samples, time of shaking in thermostatic electrical shaker and ultrasonic bath, effect of back extracting HNO 3 volume, matrix effect, centrifugation time and rate were optimized. At the sample volume of 25mL, the calculated preconcentration factor was 62.2. The limit of detection of proposed procedure for Pb +2 ions was found to be 0.54μgL -1 . The validation of developed method was performed by the analysis of certified sample of water SRM 1643e and standard addition method in a real water sample. The extraction recovery of Pb +2 was enhanced≥2% with shaking time of 80s in ultrasonic bath as compared to used thermostatic electrical shaker, where for optimum recovery up to 10min was required. The developed procedure was successfully used for the enrichment of Pb +2 in ground and stored rain water (surface water) samples of an endemic region of Pakistan. The resulted data indicated that the ground water samples were highly contaminated with Pb +2 , while some of the surface water samples were also have higher values of Pb +2 than permissible limit of WHO. The concentration of Pb +2 in surface and ground water samples was found in the range of 17.5-24.5 and 25.6-99.1μgL - 1 respectively. Copyright © 2017 Elsevier B.V. All rights reserved.
Online analysis of H2S and SO2 via advanced mid-infrared gas sensors.
Petruci, João Flavio da Silveira; Wilk, Andreas; Cardoso, Arnaldo Alves; Mizaikoff, Boris
2015-10-06
Volatile sulfur compounds (VSCs) are among the most prevalent emitted pollutants in urban and rural atmospheres. Mainly because of the versatility of sulfur regarding its oxidation state (2- to 6+), VSCs are present in a wide variety of redox-environments, concentration levels, and molar ratios. Among the VSCs, hydrogen sulfide and sulfur dioxide are considered most relevant and have simultaneously been detected within naturally and anthropogenically caused emission events (e.g., volcano emissions, food production and industries, coal pyrolysis, and various biological activities). Next to their presence as pollutants, changes within their molar ratio may also indicate natural anomalies. Prior to analysis, H2S- and SO2-containing samples are usually preconcentrated via solid sorbents and are then detected by gas chromatographic techniques. However, such analytical strategies may be of limited selectivity, and the dimensions and operation modalities of the involved instruments prevent routine field usage. In this contribution, we therefore describe an innovative portable mid-infrared chemical sensor for simultaneously determining and quantifying gaseous H2S and SO2 via coupling a substrate-integrated hollow waveguides (iHWG) serving as a highly miniaturized mid-infrared photon conduit and gas cell with a custom-made preconcentration tube and an in-line UV-converter device. Both species were collected onto a solid sorbent within the preconcentrator and then released by thermal desorption into the UV-device. Hydrogen sulfide is detected by UV-assisted quantitative conversion of the rather weak IR-absorber H2S into SO2, which provides a significantly more pronounced and distinctively detectable rovibrational signature. Modulation of the UV-device system (i.e., UV-lamp on/off) enables discriminating between SO2 generated from H2S conversion and abundant SO2 signals. After optimization of the operational parameters, calibrations in the range of 0.75-10 ppmv with a limit of detection (LOD) at 77 ppbv for SO2 and 207 ppbv for H2S were established after 20 min of sampling time at 200 mL min(-1). Taking advantage of the device flexibility in terms of sampling time, flow-rate, and iHWG design facilitates tailoring the developed Preconcentrator-UV-device-iHWG device toward a wide variety of application scenarios ranging from environmental/atmospheric monitoring to industrial process monitoring and clinical diagnostics.
NASA Astrophysics Data System (ADS)
Volino, F.
Le travail faisant l'objet de cette série d'articles de titre général "Théorie visco-élastique non-extensive", numérotée de (I) à (VI), a été initialement motivé par l'analyse de mesures de Résonance Magnétique Nucléaire (RMN) sur des polymères nématogènes dans les phases nématique et isotrope [1,2,3,4,5,6,7,8]. Sans entrer dans le détail de ces mesures, rappelons que les mouvements des molécules rétrécissent les raies RMN, mais que, avec des molécules aussi grosses que ces polymères, on est en dehors du régime de rétrécissement extrême, donc dans un régime ou la forme de raie dépend du détail des mouvements [9]. La théorie des modes élastiques des nématiques fournissait le cadre conceptuel naturel pour décrire de tels mouvements. L'application de cette théorie, qui, dans une version simplifiée, mais suffisante en pratique, ne fait intervenir que deux paramètres ajustables, le paramètre d'ordre nématique et une viscosité moyenne, a effectivement permis de reproduire dans le détail des formes de raie RMN de polymères en phase nématique, avec des valeurs des deux paramètres en accord avec celles qui avaient pu être estimées par des mesures directes. La théorie des modes élastiques était donc testée avec succès par l'analyse de formes de raies RMN. L'analyse en phase nématique apparaissait bien auto-cohérente [5]. Une incohérence logique est cependant apparue dans les études qui ont suivi. Les ajustements précédents avaient été faits pour des spectres obtenus au milieu de la phase nématique, ou l'ordre orientationnel est relativement élevé. Cependant, l'ordre diminue en chauffant, et on a trouvé qu'il est toujours possible de simuler les formes de raies avec le même modèle, en changeant les valeurs du paramètre d'ordre et de la viscosité. - la transition nématique-isotrope, l'expérience montre que l'allure générale des spectres RMN du polymère change peu, et le calcul montre qu'ils peuvent être simulés, de façon quasi-parfaite, par le même modèle, en supposant que l'échantillon soit "en poudre", et avec des valeurs très faibles du paramètre d'ordre. Une phase isotrope de polymère nématique étant un polymère normal, on a alors testé le modèle avec un polymère conventionnel, et de la même façon, de très bonnes simulations ont été obtenues. L'incohérence logique associée à ces résultats vient du fait que la théorie des modes élastiques ne devrait plus être applicable. En effet, le point de départ de cette théorie est une fonctionnelle énergie libre du nématique distordu par les fluctuations thermiques, qui ne contient que le terme quadratique en gradient d'orientation des molécules par rapport au directeur moyen. La limitation à ce premier terme signifie que la description ne devrait être valable que pour des gradients faibles, donc des paramètres d'ordre élevés. On aboutit donc au paradoxe suivant : la théorie des modes élastiques des nématiques permet de décrire d'autant mieux les spectres RMN de polymères, nématiques ou non, que le paramètre d'ordre est faible, c'est-à-dire qu'elle sort de son domaine d'applicabilité présumé. La façon la plus simple d'expliquer cette situation paradoxale est de dire que si la théorie des modes élastiques marche très bien en toutes circonstances, c'est parce qu'elle est beaucoup plus générale que ne l'ont (implicitement) imaginé leurs auteurs. Mais pour que tout redevienne cohérent, il fallait changer la signification d'au moins un concept de base de la théorie. Il a été décidé de modifier la signification des constantes élastiques et des viscosités, telles qu'elles apparaissent au niveau des équations fondamentales de la théorie standard. En pratique, la modification qui a été faite a été de supposer que ces quantités ne sont pas les quantités macroscopiques, mais des quantités non mesurables, associées aux modes élastiques, dépendant du vecteur d'onde et de la température, selon des formules simples, du type de celles obtenues par les méthodes du groupe de renormalisation, dans la théorie des changements de phase. Dans l'article (I) intitulé "Théorie simplifiée à modes rotationnels", des conséquences nécessaires de cette hypothèse, en phase nématique et isotrope, sont déduites, et un certain nombre de quantités mesurables sont calculées : élasticité, viscosité, effets de champ appliqués, chaleur spécifique... Le formalisme est unifié dans la mesure où les relations obtenues sont valables de part et d'autre de la transition. Le caractère le plus important de ces résultats est cependant le fait que toutes les quantités macroscopiques dépendent de façon non-triviale de la taille de l'échantillon, caractère que l'on a qualifié de "non-extensif". Dans l'article (II) intitulé "Premiers tests expérimentaux de la théorie simplifiée à modes rotationnels", l'ensemble des prédictions décrit dans l'article (I) est testé à l'aide de données de la littérature concernant trois nématiques typiques, pour lesquels la plupart des quantités ont été mesurées indépendamment par différents auteurs. Outre un accord quantitatif étonnant avec l'expérience, cette théorie permet aussi d'expliquer les écarts souvent obtenus par différents auteurs. Le modèle fonctionnant très bien pour décrire les propriétés rotationnelles des phases isotropes, il a été tentant de voir s'il pouvait aussi décrire les propriétés translationnelles. C'est ce qui fait l'objet de l'article (III) intitulé "Théorie simplifiée à modes translationnels". Moyennant une hypothèse concernant la forme mathématique de la contribution à la fonctionnelle énergie libre associée à l'existence de mouvements macroscopiques dans le fluide, couplant les gradients de vitesse aux fluctuations thermiques, on a pu obtenir des expressions, toujours non-extensives, d'un certain nombre de quantités mesurables, dont les coefficients de transport. Dans l'article (IV), intitulé "Premiers tests expérimentaux de la théorie simplifiée à modes translationnels", ces prédictions sont testées à l'aide de données de la littérature sur des liquides simples, dont l'eau. Le résultat est positivement troublant. Il rend compte en particulier des différences observées par des expérimentateurs indépendants mesurant la simple viscosité et surtout le coefficient de diffusion de l'eau pure. Ce liquide n'apparaît d'ailleurs pas comme un cas particulier. Il faut remarquer cependant que cet écart à l'extensivité, supposée depuis toujours dans tous les modèles, n'était pas prévisible a priori, mais que le modèle contient lui-même les conditions nécessaires à son applicabilité. Le fait que ces écarts à l'extensivité ne peuvent être observés que dans certaines conditions s'explique, et il n'y a aucune contradiction avec l'utilisation des modèles extensifs dans la technologie. Dans l'article (V) intitulé "Équations de diffusion, fonctions de distribution, viscosités et coefficients de diffusion, fonctions de corrélation", est abordée une extension de la théorie à la généralisation des équations de diffusion des théories standards. Avec ces équations généralisées apparaissent naturellement les notions de déplacement élastique, décrivant des mouvements aléatoires locaux de faible amplitude, et de déplacement visqueux, décrivant les mouvements aléatoires à grande distance. À chacun de ces deux types de mouvements est associé un temps caractéristique propre, et on montre que ces deux temps peuvent différer d'un grand nombre d'ordre de grandeurs à suffisamment basse température. Les fonctions de corrélations associées à différentes méthodes spectroscopiques sont calculées à l'aide de ces équations de diffusion. On trouve que ces fonctions ne sont pas des exponentielles, mais plutôt des "exponentielles étirées", la forme exponentielle pure n'étant qu'une approximation valide aux temps suffisamment courts, et aux temps suffisamment longs. Enfin, dans l'article (VI) intitulé "Application à un liquide formant une phase vitreuse, l'orthoterphényl (OTP)", la plupart des résultats théoriques obtenus dans les articles précédents est appliqué à la description d'un grand nombre de données expérimentales variées de la littérature, obtenues avec ce système exemplaire. On montre qu'il est ainsi possible de rationaliser l'ensemble de ces données. En particulier, la température de transition vitreuse apparaît comme la limite basse température d'une transition de phase très étalée depuis la température de fusion du cristal, analogue à la transition nématique-isotrope, mais de nature à la fois translationnelle et rotationnelle. Il faut admettre que les conséquences du modèle fabriqué à l'origine pour interpréter des expériences RMN, et surtout celles de son extension en dehors du domaine des seuls cristaux liquides a de quoi surprendre au premier abord. C'est seulement après une revue très complète d'un grand nombre de résultats expérimentaux, revue qui a pris beaucoup de temps et n'a jamais révélé de contradiction, qu'il a été décidé de soumettre ce modèle à l'attention de la communauté. Ce travail ne peut être considéré comme un aboutissement. Un certain nombre d'aspects n'ont pas été abordés. Par exemple, pour les substances nématogènes, le test de la description unifiée des résultats de diffusion de la lumière, qui a été la motivation historique du développement de la théorie standard des modes élastiques pour décrire ces résultats en phase nématique, n'a pas été traité. Autre exemple : pour les liquides usuels, on s'est limité à des situations loin du point critique, c'est-à-dire quand la présence de la phase gazeuse au-dessus du liquide peut être ignorée. Il convient donc de généraliser la théorie au problème des liquides peu denses, ainsi que d'explorer sa possible extension à la phase gazeuse et voir si on peut appliquer ce type de description au système liquide-gaz. Enfin, les aspects purement mécaniques n'ont pas été abordés. Puisque l'élasticité intervient de façon fondamentale dans la description, il faut reformuler la mécanique des fluides standard pour qu'apparaisse explicitement la notion d'élasticité dans les équations. C'est cette reformulation, dont on verra qu'elle permet de décrire de façon unifiée l'essentiel des comportements rhéologiques des fluides (passage continu entre les réponses élastique, visco-élastique, plastique et visqueuse, en fonction de la nature, la durée et l'intensité des sollicitations mécaniques, ainsi que de la température), qui sera l'objet du prochain article de cette série. Enfin, on peut se demander comment raccorder le formalisme hautement non-conventionnel de cette théorie, qui permet de calculer des quantités physiques mesurables, à celui de la théorie statistique standard, qui permet en principe de calculer les mêmes quantités. Ce problème reste pour l'instant ouvert, mais la piste à suivre pour le résoudre semble claire. Elle est probablement contenue dans la forme postulée dans (III) pour le couplage entre les mouvements aléatoires microscopiques, lesquels sont décrits de façon uniquement statistique (à l'aide d'équations de diffusion), et les mouvements macroscopiques qui sont décrits de façon mécaniste. En d'autres termes, on introduit un indéterminisme fondamental dans la description du mouvement des objets. Le raccord avec la théorie standard ne pourra donc se faire qu'au niveau de la statistique quantique, qui elle aussi contient dans son essence un indéterminisme du même type. Une comparaison détaillée ne sera possible que dans un stade ultérieur du développement de la présente théorie, quand tous les aspects mécaniques, dont certains ont été évoqués plus haut, auront été explorés. Il est espéré que ces informations préliminaires aideront le lecteur à la compréhension des articles (I) à (VI) proposés.
Shields, C Wyatt; Reyes, Catherine D; López, Gabriel P
2015-03-07
Accurate and high throughput cell sorting is a critical enabling technology in molecular and cellular biology, biotechnology, and medicine. While conventional methods can provide high efficiency sorting in short timescales, advances in microfluidics have enabled the realization of miniaturized devices offering similar capabilities that exploit a variety of physical principles. We classify these technologies as either active or passive. Active systems generally use external fields (e.g., acoustic, electric, magnetic, and optical) to impose forces to displace cells for sorting, whereas passive systems use inertial forces, filters, and adhesion mechanisms to purify cell populations. Cell sorting on microchips provides numerous advantages over conventional methods by reducing the size of necessary equipment, eliminating potentially biohazardous aerosols, and simplifying the complex protocols commonly associated with cell sorting. Additionally, microchip devices are well suited for parallelization, enabling complete lab-on-a-chip devices for cellular isolation, analysis, and experimental processing. In this review, we examine the breadth of microfluidic cell sorting technologies, while focusing on those that offer the greatest potential for translation into clinical and industrial practice and that offer multiple, useful functions. We organize these sorting technologies by the type of cell preparation required (i.e., fluorescent label-based sorting, bead-based sorting, and label-free sorting) as well as by the physical principles underlying each sorting mechanism.
Shields, C. Wyatt; Reyes, Catherine D.; López, Gabriel P.
2015-01-01
Accurate and high throughput cell sorting is a critical enabling technology in molecular and cellular biology, biotechnology, and medicine. While conventional methods can provide high efficiency sorting in short timescales, advances in microfluidics have enabled the realization of miniaturized devices offering similar capabilities that exploit a variety of physical principles. We classify these technologies as either active or passive. Active systems generally use external fields (e.g., acoustic, electric, magnetic, and optical) to impose forces to displace cells for sorting, whereas passive systems use inertial forces, filters, and adhesion mechanisms to purify cell populations. Cell sorting on microchips provides numerous advantages over conventional methods by reducing the size of necessary equipment, eliminating potentially biohazardous aerosols, and simplifying the complex protocols commonly associated with cell sorting. Additionally, microchip devices are well suited for parallelization, enabling complete lab-on-a-chip devices for cellular isolation, analysis, and experimental processing. In this review, we examine the breadth of microfluidic cell sorting technologies, while focusing on those that offer the greatest potential for translation into clinical and industrial practice and that offer multiple, useful functions. We organize these sorting technologies by the type of cell preparation required (i.e., fluorescent label-based sorting, bead-based sorting, and label-free sorting) as well as by the physical principles underlying each sorting mechanism. PMID:25598308
NASA Astrophysics Data System (ADS)
Cheikhrouhou, Abdelwaheb
2012-02-01
The national conference 'MATERIAUX 2010', which took place in Mahdia (Tunisia), from 4-7 November 2010 was organized by The 'Tunisian Materials Research Society: Tu-MRS' in collaboration with the Materials Physics Laboratory of Sfax 'LPM', Faculty of Sciences, Sfax University and the Research Unit ' Physique, Informatique et Mathématiques ', Faculty of Sciences, Gafsa University The First National Conference on Materials 'MATERIAUX 2006' was organized in Douz (Tunisia) in December 2006. This was followed by 'MATERIAUX 2007' held in Hammamet (Tunisia) in April 2007 and the National Conference 'MATERIAUX 2009' organized jointly with the Second 'Journées Internationales de la Physique des Matériaux et Applications: JIPMA 2009' in Gafsa (Tunisia) from 20-24 December 2009. 'MATERIAUX 2010' is intended to provide an excellent opportunity for National, Maghreb and International researchers to make their own work on materials known to a wider audience and to have discussions with other participants. This conference will also be an opportunity to exchange experiences, create and consolidate cooperation between different research structures in the Maghreb countries and also the countries around the Mediterranean. This conference will equally promote research development, contribution to collaboration between universities and the socio-economical milieu. More than 300 senior researchers, Professors, PhD and Masters students attended this conference from Tunisia, Algeria, Morocco, France, Spain and Canada. Several researchers, engineers and managers from industrial firms also attended. The conference consisted of plenary talks (8), oral contributions (40) and poster presentations (250). The topics of the Conference were: Nano-materials, nano-systems, thin films, surfaces and interfaces, applications Multifunctionnal materials, magnetic materials, dielectric materials, superconducting materials, applications,... Materials for electronics, informatics and communication Ceramics, glasses, polymers Natural materials (phosphates, clay,...) Metallic materials, alloys, metallurgy,... Others (materials and environment, materials and energy, biomaterials,...) I want to thank the scientific committee, the organizing committee, the local committee and everyone who contributed to the organization of this meeting for their invaluable efforts in order to guarantee the complete success of this conference. Abdelwaheb Cheikhrouhou President of 'Tu-MRS' Chairman of the Conference 'MATERIAUX 2010' Conference photograph Committies Organizing Committee Chairman CHEIKHROUHOU Abdelwaheb (Faculté des Sciences de Sfax) Members ALAYA Sahbi (Faculté des Sciences de Gabès) BENNACEUR Raouf (Faculté des Sciences de Tunis) BEN SALEM Mohamed (Faculté des Sciences de Bizerte) CHEIKHROUHOU-KOUBAA Wissem (Faculté des Sciences de Sfax) EL JANI Belgacem (Faculté des Sciences de Monastir) EZZAOUIA Hatem (Centre de Recherches et de Technologies de l'Energie, Technopole de Borj Cédria) LAMLOUMI Jilani (Ecole Supérieure des Sciences et Techniques de Tunis) REZIG Bahri (Ecole Nationale d'Ingénieurs de Tunis) Local Committee Chairman CHEIKHROUHOU Abdelwaheb (Faculté des Sciences de Sfax) Members CHEIKHROUHOU-KOUBAA Wissem (Faculté des Sciences de Sfax) KOUBAA Mohamed (Institut Supérieur de Biotechnologie de Sfax) NJEH Anwar (Institut Préparatoire aux Etudes d'Ingénieurs de Sfax) BEN SALAH Issam (Faculté des Sciences de Sfax) TAKKALI Férid (Faculté des Sciences de Sfax) REGAIEG Yassin (Faculté des Sciences de Sfax) OTHMANI Safa (Faculté des Sciences de Sfax) MNASSRI Rafik (Faculté des Sciences de Sfax) Secretariat BEN GHOZLEN Afifa (Faculté des Sciences de Sfax) BOUGHARIOU Sana (Faculté des Sciences de Sfax) Scientific Committee M. ADDOU, Faculté des Sciences de Kénitra (Morocco) N. AMDOUNI, Faculté des Sciences de Tunis (Tunisia) M. BACCOUCHE, Faculté des Sciences d'Annaba (Algeria) H. BATIS, Faculté des Sciences de Tunis (Tunisia) A. BELAFHAL, Faculté des Sciences d'El Jadida (Morocco) M.H. BEN GHOZLEN, Faculté des Sciences de Sfax (Tunisia) R. BENNACEUR, Faculté des Sciences de Tunis (Tunisia) B. BENYOUCEF, Université Abou Bakr Belkaid, Tlemcen (Algeria) M. BEN SALEM, Faculté des Sciences de Bizerte (Tunisia) B. BESSAIES, Centre de Recherches et Technologies de l'Energie (Tunisia) H. BOUCHRIHA, Faculté des Sciences de Tunis (Tunisia) W. BOUJELBEN, Faculté des Sciences de Sfax (Tunisia) A. CHEIKHROUHOU, Faculté des Sciences de Sfax (Tunisia) W. CHEIKHROUHOU-KOUBAA, Faculté des Sciences de Sfax (Tunisia) R. CHTOUROU, Centre de Recherches et Technologies de l'Energie (Tunisia) M. DEBBABI, Ecole Nationale d'Ingénieurs de Monastir (Tunisia) A. DAKHLAOUI, Faculté des Sciences de Bizerte (Tunisia) A. DINIA, Université de Strasbourg (France) B. ELJANI, Faculté des Sciences de Monastir (Tunisia) A. ELJAZOULI, Faculté des Sciences Ben Msik, Casablanca (Morocco) Z. FAKHFAKH, Faculté des Sciences de Sfax (Tunisia) A. GASMI, Faculté des Sciences d'Annaba (Algeria) A. GHARBI, Faculté des Sciences de Tunis (Tunisia) R. GHARBI, Faculté des Sciences de Sfax (Tunisia) K. GUIDARA, Faculté des Sciences de Sfax (Tunisia) H. GUERMAZI, Institut Préparatoire aux Etudes d'Ingénieurs de Sfax (Tunisia) S. GUERMAZI, Faculté des Sciences de Sfax (Tunisia) M. HADDAD, Faculté des Sciences de Meknès (Morocco) A. HAJ AMARA, Faculté des Sciences de Bizerte (Tunisia) D. HAMANA, Faculté des Sciences de Constantine (Algeria) N. KAMOUN, Faculté des Sciences de Tunis (Tunisia) S. KADDOUR-CHARFI, Faculté des Sciences de Tunis (Tunisia) M. KADDOUR, Faculté des Sciences de Sfax (Tunisia) M. KHITOUNI, Faculté des Sciences de Sfax (Tunisia) T. MHIRI, Faculté des Sciences de Sfax (Tunisia) Y. MLIK, Institut Préparatoire aux Etudes Scientifiques et Techniques (Tunisia) N. MLIKI, Faculté des Sciences de Tunis (Tunisia) A. NJAH, Faculté des Sciences de Gafsa (Tunisia) M. OUESLATI, Faculté des Sciences de Tunis (Tunisia) K. ZELLAMA, Faculté des Sciences d'Amiens (France) Invited Speakers AMMAR-MERIAH Souad, ITODYS, Université Paris Diderot (France) BEN SALEM Mohamed, Faculté des Sciences de Bizerte, Université du 7 Novembre á Carthage (Tunisia) CHEIKHROUHOU Abdelwaheb, Faculté des Sciences de Sfax, Université de Sfax (Tunisia) DAKHLAOUI Amel, Faculté des Sciences de Bizerte, Université du 7 Novembre á Carthage (Tunisia) DJABBAR Ahmed, Université des Sciences et des Technologies de Lille (France) DURASTANTI Félix, Centre d'Etudes et Recherche en Thermique, Environnement et Systèmes (C.E.R.T.E.S.), Université Paris Est- Créteil (France) FERY-FORGUES Suzanne, Université Paul Sabatier, Toulouse (France) GIRAUD Romain, Laboratoire de Photonique et de Nanostructures, CNRS/LPN, Marcoussis (France)
NASA Astrophysics Data System (ADS)
Veres, Teodor
Cette these est consacree a l'etude de l'evolution structurale des proprietes magnetiques et de transport des multicouches Ni/Fe et nanostructures a base de Co et de l'Ag. Dans une premiere partie, essentiellement bibliographique, nous introduisons quelques concepts de base relies aux proprietes magnetiques et de transport des multicouches metalliques. Ensuite, nous presentons une breve description des methodes d'analyse des resultats. La deuxieme partie est consacree a l'etude des proprietes magnetiques et de transport des multicouches ferromagnetiques/ferromagnetiques Ni/Fe. Nous montrerons qu'une interpretation coherente de ces proprietes necessite la prise en consideration des effets des interfaces. Nous nous attacherons a mettre en evidence, a evaluer et a etudier les effets de ces interfaces ainsi que leur evolution, et ce, suite a des traitements thermiques tel que le depot a temperature elevee et l'irradiation ionique. Les analyses correlees de la structure et de la magnetoresistance nous permettront d'emettre des conclusions sur l'influence des couches tampons entre l'interface et le substrat ainsi qu'entre les couches elles-memes sur le comportement magnetique des couches F/F. La troisieme partie est consacree aux systemes a Magneto-Resistance Geante (MRG) a base de Co et Ag. Nous allons etudier l'evolution de la microstructure suite a l'irradiation avec des ions Si+ ayant une energie de 1 MeV, ainsi que les effets de ces changements sur le comportement magnetique. Cette partie debutera par l'analyse des proprietes d'une multicouche hybride, intermediaire entre les multicouches et les materiaux granulaires. Nous analyserons a l'aide des mesures de diffraction, de relaxation superparamagnetique et de magnetoresistance, les evolutions structurales produites par l'irradiation ionique. Nous etablirons des modeles qui nous aideront a interpreter les resultats pour une serie des multicouches qui couvrent un large eventail de differents comportements magnetiques et ceci en fonction de l'epaisseur de la couche magnetique de Co. Nous verrons que dans ces systemes les effets de l'irradiation ionique sont fortement influences par l'energie de surface ainsi que par l'enthalpie de formation, largement positive pour le systeme Co/Ag.
A Binary Array Asynchronous Sorting Algorithm with Using Petri Nets
NASA Astrophysics Data System (ADS)
Voevoda, A. A.; Romannikov, D. O.
2017-01-01
Nowadays the tasks of computations speed-up and/or their optimization are actual. Among the approaches on how to solve these tasks, a method applying approaches of parallelization and asynchronization to a sorting algorithm is considered in the paper. The sorting methods are ones of elementary methods and they are used in a huge amount of different applications. In the paper, we offer a method of an array sorting that based on a division into a set of independent adjacent pairs of numbers and their parallel and asynchronous comparison. And this one distinguishes the offered method from the traditional sorting algorithms (like quick sorting, merge sorting, insertion sorting and others). The algorithm is implemented with the use of Petri nets, like the most suitable tool for an asynchronous systems description.
A Quality Sorting of Fruit Using a New Automatic Image Processing Method
NASA Astrophysics Data System (ADS)
Amenomori, Michihiro; Yokomizu, Nobuyuki
This paper presents an innovative approach for quality sorting of objects such as apples sorting in an agricultural factory, using an image processing algorithm. The objective of our approach are; firstly to sort the objects by their colors precisely; secondly to detect any irregularity of the colors surrounding the apples efficiently. An experiment has been conducted and the results have been obtained and compared with that has been preformed by human sorting process and by color sensor sorting devices. The results demonstrate that our approach is capable to sort the objects rapidly and the percentage of classification valid rate was 100 %.
NASA Astrophysics Data System (ADS)
Fall, H.; Charon, W.; Kouta, R.
2002-12-01
Ces dernières décennies, des activités significatives dans le monde étaient dirigées autour du contrôle actif. Le but de ces recherches était essentiellement d'améliorer les performances, la fiabilité et la sécurité des systèmes. Notamment dans le cas des structures soumises à des vibrations aléatoires. D'importants travaux ont été consacré à l'utilisation des “matériaux intelligents” comme capteurs et actionneurs. Cette article propose l'analyse de la fiabilité des systèmes mécaniques en étudiant les pannes des actionneurs ou des capteurs. L'effet de ces pannes sur la stabilité et la performance du système y est démontré. Les méthodologies de conception y sont rappelées. Des exemples numériques sont fournis à travers le contrôle d'un panneau sous chargement dynamique pour illustrer la méthode proposée.
Diethylstilbestrol-Induced Mouse Hypospadias: “Window of Susceptibility”
Sinclair, Adriane Watkins; Cao, Mei; Baskin, Laurence; Cunha, Gerald R.
2016-01-01
Hypospadias, an abnormality affecting the penile urethra, is one of the most prevalent congenital malformations afflicting human males. The morphology of hypospadias is markedly different in humans versus mice reflecting substantial differences in penile development in humans and mice. Estrogens such as diethylstilbestrol (DES) elicit mouse penile malformations, but the types of penile abnormalities differ depending on whether DES treatment is prenatal or neonatal. To define the actual “window of susceptibility” to the adverse effects of DES, pregnant mice and their neonatal pups were injected subcutaneously with 200ng/gbw DES every other day from embryonic day 12 to 18 (DES E12-E18), postnatal day 0 to 10 (DES P0-P10), embryonic day 12 to postnatal day 10 (DES E12 to P10), postnatal day 5 to 15 (DES P5 to P15), and postnatal day 10 to 20 (DES P10 to P20). Aged-matched controls received sesame oil vehicle. After euthanasia at 10, 15, 20 and 60 days, penises were analyzed by gross morphology, histology and morphometry. Penises of all 5 groups of DES-treated mice were reduced in size, which was confirmed by morphometric analysis of internal penile structures. The most profound effects were seen in the DES E12-P10, DES P0-P10, and DES P5-P15 groups, thus defining a DES “programming window”. For all parameters, DES treatment from P10-P20 showed the most mild of effects. Adverse effects of DES on the MUMP cartilage and erectile bodies observed shortly after the last DES injection reverted to normality in the DES P5-P15, but not in the E12-P10 and P0-P10 groups, in which MUMP cartilage and erectile body malformations persisted into adulthood, again emphasizing a “window of susceptibility” in the early neonatal period. PMID:26810244
La manucure et la pédicure dans la ville de Ouagadougou (Burkina Faso): pratiques et risqué
Korsaga-Somé, Nina; Andonaba, Jean Baptiste; Ouédraogo, Muriel Sidnoma; Tapsoba, Gilbert Patrice; Ilboudo, Léopold; Savadogo, Cérina; Barro-Traoré, Fatou; Niamba, Pascal; Traoré, Adama
2016-01-01
La manucure-pédicure est l'ensemble des soins esthétiques des mains, des pieds et des ongles. Au Burkina Faso, l'usage des produits de manucure-pédicure, les techniques utilisées ainsi que les risques encourus restent méconnus. L'objectif de notre étude était d’évaluer la pratique de la manucure-pédicure dans la ville de Ouagadougou. Nous avons mené une étude transversale descriptive de décembre 2010 à novembre 2012 incluant tout les praticiens ayant au moins six mois d'expérience dans l'activité et les clients présents sur les lieux au moment de l'enquête. Nous avons interrogé au total 313 praticiens et 313 clients. L’âge moyen des praticiens était de 19 ans et celui des clients de 32,2 ans. Les praticiens fixes étaient en majorité des femmes (96,87%), ceux mobiles surtout des hommes (68,37%), et 64,53% des clients étaient des femmes. Le pourcentage de praticiens n'ayant pas reçu de formation professionnelle était de 93,92%. 29,7% des praticiens faisaient tremper les instruments pendant au moins dix minutes dans de l'eau de javel; 75,71% savaient que l'utilisation de certains outils étaient dangereux et 26,51% étaient avaient présenté des effets secondaires. Parmi les clients, 40,25% savaient que le matériel utilisé comportait des risques et 30,35% avaient été victimes d'accidents. Les soins de manucure et de pédicure se font dans les salons de coiffure par des coiffeuses non formées à l'exercice de la profession La provenance et la composition des produits n'est pas connues. Des produits non recommandés sont utilisés (shampooing pour trempage des pieds, lame de rasoir et ciseaux pour raclage des pieds). Le recours à la manucure et/ou pédicure est parfois nécessaire mais cela ne doit pas faire perdre de vue les risques encourus. Une sensibilisation des clients et une formation des praticiens semblent nécessaires pour minimiser les risques. PMID:27642448
La prise en charge des troubles de santé mentale par les omnipraticiens du Québec
Fleury, Marie-Josée; Farand, Lambert; Aubé, Denise; Imboua, Armelle
2012-01-01
Résumé Objectif Cette recherche vise à documenter la prise en charge des troubles mentaux (TM) par les omnipraticiens. Type d’étude Il s’agit d’une étude mixte intégrant un questionnaire auto-administré et des entrevues qualitatives. La banque de données administratives des actes médicaux de la Régie de l’assurance maladie du Québec a aussi été analysée. Contexte La province de Québec. Participants Un total de 1415 omnipraticiens de différents lieux de pratiques ont été sollicités pour le questionnaire; 970 ont été rejoints. Un sous-groupe de 60 omnipraticiens a été rejoint pour les entrevues. Principaux paramètres à l'étude La prévalence annuelle des consultations reliées à des TM courants (TMC) ou graves (TMG), les pratiques cliniques, les pratiques de collaboration, les facteurs facilitant ou entravant la prise en charge des TM, ainsi que les recommandations pour l’amélioration du système de soins. Résultats Le taux de réponse a été de 41% (n = 398 omnipraticiens) pour le questionnaire et de 63% (n = 60) pour les entrevues. Environ 25 % des visites chez les omnipraticiens sont associées à des TM. Presque tous les omnipraticiens prennent en charge des TMC et se sentent compétents pour le faire, à l’inverse de la situation retrouvée pour les TMG. Près de 20 % des TMC sont référés (principalement à des intervenants psychosociaux), alors que près de 75 % des TMG sont référés (surtout en psychiatrie et à l’urgence). Plus de 50 % des omnipraticiens affirment n’entretenir aucun contact avec l’une ou l’autre des ressources de santé mentale. Plusieurs facteurs influencent la prise en charge des TM: les profils des patients (complexité des TM, troubles concomitants); les caractéristiques des omnipraticiens (réseau informel, formation); la culture professionnelle (travail en silo, mécanismes cliniques formalisés); le milieu institutionnel (multidisciplinarité, salariat); l’organisation des services (ressources; coordination formalisée) et l’environnement (politiques). Conclusion Le rôle clé des omnipraticiens et leur soutien à la prise en charge des TM ont été démontrés, spécifiquement pour les TMC. Pour une prise en charge optimale des soins primaires de santé mentale, des stratégies à composantes multiples, dont les soins partagés, devraient être davantage déployées.
NASA Astrophysics Data System (ADS)
Umbarkar, A. J.; Balande, U. T.; Seth, P. D.
2017-06-01
The field of nature inspired computing and optimization techniques have evolved to solve difficult optimization problems in diverse fields of engineering, science and technology. The firefly attraction process is mimicked in the algorithm for solving optimization problems. In Firefly Algorithm (FA) sorting of fireflies is done by using sorting algorithm. The original FA is proposed with bubble sort for ranking the fireflies. In this paper, the quick sort replaces bubble sort to decrease the time complexity of FA. The dataset used is unconstrained benchmark functions from CEC 2005 [22]. The comparison of FA using bubble sort and FA using quick sort is performed with respect to best, worst, mean, standard deviation, number of comparisons and execution time. The experimental result shows that FA using quick sort requires less number of comparisons but requires more execution time. The increased number of fireflies helps to converge into optimal solution whereas by varying dimension for algorithm performed better at a lower dimension than higher dimension.
Effets de la formation sur la violence conjugale
Zaher, Eman; Keogh, Kelly; Ratnapalan, Savithiri
2014-01-01
Résumé Objectif Décrire et évaluer l’efficacité de la formation concernant la violence conjugale pour améliorer les connaissances et permettre la reconnaissance et la prise en charge par les médecins des femmes victimes de violence. Sources des données On a fait une recension dans la base de données des révisions systématiques de Cochrane, MEDLINE, PubMed, PsycINFO, ERIC et EMBASE pour trouver des articles publiés entre le 1e janvier 2000 et le 1e novembre 2012. Des recherches manuelles ont complété cette recension pour cerner des articles pertinents à l’aide d’une stratégie de recherche combinant des textes, mots et expressions MeSH. Sélection des études On a choisi des études randomisées contrôlées qui portaient sur des interventions éducatives à l’intention des médecins et fournissaient des données sur les effets des interventions. Synthèse On a inclus 9 études randomisées contrôlées qui décrivaient différentes approches pédagogiques et diverses mesures des résultats. Trois études examinaient les effets d’interventions éducatives pour des médecins en formation postdoctorale et ont constaté une augmentation des connaissances, mais il n’y a eu aucun changement dans le comportement en ce qui a trait à l’identification des victimes de violence conjugale. Six études portaient sur des interventions éducatives pour des médecins en pratique active. Trois d’entre elles utilisaient une approche à multiples facettes pour les médecins, qui combinait une formation ainsi que des interventions de soutien de la part du système pour changer les comportements des médecins, comme une sensibilisation générale accrue à la violence conjugale au moyen de brochures et d’affiches, des aide-mémoire pour rappeler aux médecins comment identifier les victimes, des moyens pour faciliter l’accès des médecins à des services de soutien pour les victimes, la réalisation d’audits et la fourniture de rétroaction. Les interventions éducatives à multiples facettes prenaient la forme d’ateliers interactifs, d’apprentissage sur le web et de formation expérientielle. Une autre étude utilisait des discussions de groupes témoins et de la formation et a permis de constater une amélioration dans le signalement de la violence conjugale par les médecins. Les 2 autres études ont relevé une meilleure perception par les médecins en pratique de leur confiance en eux à l’aide d’apprentissage par problèmes en ligne. Conclusion Il a été difficile de déterminer quelle stratégie pédagogique était la plus efficace étant donné que les interventions éducatives et les mesures des résultats variaient entre les études choisies. De brèves interventions pour les médecins en formation postdoctorale amélioraient les connaissances mais ne semblaient pas influencer les comportements. La formation en ligne sous forme d’apprentissage par problèmes améliorait les perceptions des médecins en pratique, leurs connaissances et leurs habiletés quant à la prise en charge de la violence conjugale. La formation des médecins combinée à des interventions de soutien de la part du système semblait bénéfique aux victimes de violence conjugale et augmentait le nombre de demandes de consultations auprès des ressources de soutien à leur intention.
La prévention de l’étouffement et de la suffocation chez les enfants
Cyr, Claude
2012-01-01
RÉSUMÉ L’étouffement, la suffocation et la strangulation sont responsables de graves blessures non intentionnelles chez les enfants et constituent des causes importantes de décès non intentionnels chez les nourrissons et les tout-petits. Presque la totalité des décès et des blessures attribuables à un étouffement, une suffocation ou une strangulation sont évitables. Le présent document de principes traite des définitions, de l’épidémiologie et des stratégies de prévention efficaces de ces blessures. Des recommandations qui combinent des démarches pour améliorer la sécurité, incluant des recherches, de la surveillance, des lois et des normes, la conception des produits et l’éducation, sont présentées. Les dispensateurs de soins pédiatriques devraient encourager les parents et autres personnes qui s’occupent d’enfants à apprendre la réanimation cardiorespiratoire (RCR) et les premiers soins en cas d’étouffement, et leur offrir des conseils préventifs adaptés à l’âge de leur enfant lors des bilans de santé réguliers afin de prévenir ces blessures.
Measuring Effects and Success in Influence Operations: Challenges, Limitations and Opportunitites
2011-04-01
domaines de la psychologie , de l’anthropologie et de la sociologie, ainsi que sur des entrevues menées auprès de pionniers des technologies de...documents issus des domaines de la psychologie , de l’anthropologie et de la sociologie, ainsi que sur des entrevues menées auprès de pionniers des...la psychologie , de l’anthropologie et de la sociologie, ainsi que sur des entrevues menées auprès de pionniers des technologies de l’intelligence
Learning cellular sorting pathways using protein interactions and sequence motifs.
Lin, Tien-Ho; Bar-Joseph, Ziv; Murphy, Robert F
2011-11-01
Proper subcellular localization is critical for proteins to perform their roles in cellular functions. Proteins are transported by different cellular sorting pathways, some of which take a protein through several intermediate locations until reaching its final destination. The pathway a protein is transported through is determined by carrier proteins that bind to specific sequence motifs. In this article, we present a new method that integrates protein interaction and sequence motif data to model how proteins are sorted through these sorting pathways. We use a hidden Markov model (HMM) to represent protein sorting pathways. The model is able to determine intermediate sorting states and to assign carrier proteins and motifs to the sorting pathways. In simulation studies, we show that the method can accurately recover an underlying sorting model. Using data for yeast, we show that our model leads to accurate prediction of subcellular localization. We also show that the pathways learned by our model recover many known sorting pathways and correctly assign proteins to the path they utilize. The learned model identified new pathways and their putative carriers and motifs and these may represent novel protein sorting mechanisms. Supplementary results and software implementation are available from http://murphylab.web.cmu.edu/software/2010_RECOMB_pathways/.
NASA Astrophysics Data System (ADS)
Ratnadewi; Pramono Adhie, Roy; Hutama, Yonatan; Saleh Ahmar, A.; Setiawan, M. I.
2018-01-01
Cryptography is a method used to create secure communication by manipulating sent messages during the communication occurred so only intended party that can know the content of that messages. Some of the most commonly used cryptography methods to protect sent messages, especially in the form of text, are DES and 3DES cryptography method. This research will explain the DES and 3DES cryptography method and its use for stored data security in smart cards that working in the NFC-based communication system. Several things that will be explained in this research is the ways of working of DES and 3DES cryptography method in doing the protection process of a data and software engineering through the creation of application using C++ programming language to realize and test the performance of DES and 3DES cryptography method in encrypted data writing process to smart cards and decrypted data reading process from smart cards. The execution time of the entering and the reading process data using a smart card DES cryptography method is faster than using 3DES cryptography.
Merchaoui, Irtyah; Chouchène, Asma; Bouanène, Ines; Chaari, Néila; Zrafi, Wassim; Henchi, Adnène; Akrout, Mohamed; Amri, Charfeddine
2017-01-01
Introduction L'insatisfaction de carrière des médecins de travail (MT) peut influencer leur performance et la qualité des prestations fournies. L'objectif de notre étude est d'évaluer la satisfaction au travail des MT du terrain de l'ensemble des Groupements de médecine de travail (GMT) de la Tunisie et préciser les facteurs déterminants. Méthodes Il s'agit d'une étude nationale transversale portant sur les MT de 22 GMT, basée sur le questionnaire, validé SAPHORA JOB. Résultats 58% des MT des GMT étaient insatisfaits de leur carrière. La satisfaction de carrière était statistiquement influencée par le nombre d'entreprises en charge (p=0,016), l'organisation du travail (p=0,010),le ressenti du métier (p=0,011),le salaire (p‹10-3) et l'information sur la réglementation en vigueur (p=0,047). Conclusion L'homogénéisation des grilles salariales et des échelons de carrière des MT des GMT basée sur une révision des textes législatifs est indiquée. L'amélioration de l'organisation et des conditions de travail peut permettre un épanouissement au travail et une amélioration des prestations. PMID:28819472
Birth of kids after artificial insemination with sex-sorted, frozen-thawed goat spermatozoa.
Bathgate, R; Mace, N; Heasman, K; Evans, G; Maxwell, W M C; de Graaf, S P
2013-12-01
Successful sex-sorting of goat spermatozoa and subsequent birth of pre-sexed kids have yet to be reported. As such, a series of experiments were conducted to develop protocols for sperm-sorting (using a modified flow cytometer, MoFlo SX(®) ) and cryopreservation of goat spermatozoa. Saanen goat spermatozoa (n = 2 males) were (i) collected into Salamon's or Tris catch media post-sorting and (ii) frozen in Tris-citrate-glucose media supplemented with 5, 10 or 20% egg yolk in (iii) 0.25 ml pellets on dry ice or 0.25 ml straws in a controlled-rate freezer. Post-sort and post-thaw sperm quality were assessed by motility (CASA), viability and acrosome integrity (PI/FITC-PNA). Sex-sorted goat spermatozoa frozen in pellets displayed significantly higher post-thaw motility and viability than spermatozoa frozen in straws. Catch media and differing egg yolk concentration had no effect on the sperm parameters tested. The in vitro and in vivo fertility of sex-sorted goat spermatozoa produced with this optimum protocol were then tested by means of a heterologous ova binding assay and intrauterine artificial insemination of Saanen goat does, respectively. Sex-sorted goat spermatozoa bound to sheep ova zona pellucidae in similar numbers (p > 0.05) to non-sorted goat spermatozoa, non-sorted ram spermatozoa and sex-sorted ram spermatozoa. Following intrauterine artificial insemination with sex-sorted spermatozoa, 38% (5/13) of does kidded with 83% (3/5) of kids being of the expected sex. Does inseminated with non-sorted spermatozoa achieved a 50% (3/6) kidding rate and a sex ratio of 3 : 1 (F : M). This study demonstrates for the first time that goat spermatozoa can be sex-sorted by flow cytometry, successfully frozen and used to produce pre-sexed kids. © 2013 Blackwell Verlag GmbH.
An Overview of the Canadian Forces’ Second Generation Capability-Based Planning Analytical Process
2010-09-01
gestion et intgration des capacités Feuille de route des capacits stratégiques Produits clès Plan d’investissement Plan de capacités de défense...méthodes de recherche opérationnelle objectives et subjectives permet- tant la mise en œuvre du volet « planification, gestion et intégration des ...pacités, la gestion des capacités et l’intégration des capacités. Le processus comprend des intrants, des méthodes
Sorting drops and cells with acoustics: acoustic microfluidic fluorescence-activated cell sorter.
Schmid, Lothar; Weitz, David A; Franke, Thomas
2014-10-07
We describe a versatile microfluidic fluorescence-activated cell sorter that uses acoustic actuation to sort cells or drops at ultra-high rates. Our acoustic sorter combines the advantages of traditional fluorescence-activated cell (FACS) and droplet sorting (FADS) and is applicable for a multitude of objects. We sort aqueous droplets, at rates as high as several kHz, into two or even more outlet channels. We can also sort cells directly from the medium without prior encapsulation into drops; we demonstrate this by sorting fluorescently labeled mouse melanoma cells in a single phase fluid. Our acoustic microfluidic FACS is compatible with standard cell sorting cytometers, yet, at the same time, enables a rich variety of more sophisticated applications.
Courbon, Ève; Tanguay, Cynthia; Lebel, Denis; Bussières, Jean-François
2014-01-01
RÉSUMÉ Contexte : La présence d’auteurs honorifiques et fantômes ainsi que les intérêts concurrents représentent des difficultés bien documentées, liées à la publication d’articles scientifiques. Il existe des lignes directrices encadrant la rédaction et la publication de manuscrits scientifiques, notamment celles de l’International Committee of Medical Journal Editors (ICMJE). Objectifs : L’objectif principal de cette étude descriptive et transversale visait à recenser les instructions portant sur la paternité des articles et les intérêts concurrents provenant des recommandations aux auteurs des journaux traitant de pratique pharmaceutique. L’objectif secondaire visait à déterminer des mesures correctrices pour une paternité des articles plus transparente. Méthode : La recherche a débuté par l’identification des journaux traitant de pratique pharmaceutique. La consultation des instructions aux auteurs des journaux a permis ensuite de recenser les recommandations destinées à éviter les problèmes de paternité des articles et d’intérêts concurrents. Finalement, les membres de l’équipe de recherche se sont consultés afin de définir des mesures correctrices possibles à l’intention des chercheurs. Résultats : Des 232 journaux traitant de pharmacie, 33 ont été définis comme traitant de pratique pharmaceutique. Un total de 24 (73 %) journaux mentionnaient suivre la politique de l’ICMJE, 14 (42 %) demandaient aux auteurs de remplir un formulaire de déclaration d’intérêts concurrents au moment de la soumission de l’article, 17 (52 %) présentaient une définition de la qualité d’auteur et 5 (15 %) demandaient de détailler les contributions de chaque auteur. Une grille de 40 critères a été élaborée pour définir l’attribution du statut d’auteur. Conclusion : Moins de la moitié des journaux demandait aux auteurs de transmettre un formulaire de déclaration des intérêts concurrents au moment de la soumission d’un article et seulement la moitié des journaux avait donné une définition de la qualité d’auteur. La publication scientifique de travaux sur les pratiques pharmaceutiques n’est pas à l’abri des manques de transparence liés à la publication. L’utilisation d’une grille décrivant la contribution de chaque auteur et la publication en ligne des travaux peuvent contribuer à limiter ces risques. PMID:24970938
Goto, Kosaku; Zhao, Zhijing; Matsumura, Mitsuaki; Dohi, Tomotaka; Kobayashi, Nobuaki; Kirtane, Ajay J; Rabbani, LeRoy E; Collins, Michael B; Parikh, Manish A; Kodali, Susheel K; Leon, Martin B; Moses, Jeffrey W; Mintz, Gary S; Maehara, Akiko
2015-11-01
The most common causes of in-stent restenosis (ISR) are intimal hyperplasia and stent under expansion. The purpose of this study was to use intravascular ultrasound (IVUS) to compare the ISR mechanisms of bare metal stents (BMS), first-generation drug-eluting stents (DES), and second-generation DES. There were 298 ISR lesions including 52 BMS, 73 sirolimus-eluting stents, 52 paclitaxel-eluting stents, 16 zotarolimus-eluting stents, and 105 everolimus-eluting stent. Mean patient age was 66.6 ± 1.1 years, 74.2% were men, and 48.3% had diabetes mellitus. BMS restenosis presented later (70.0 ± 66.7 months) with more intimal hyperplasia compared with DES (BMS 58.6 ± 15.5%, first-generation DES 52.6 ± 20.9%, second-generation DES 48.2 ± 22.2%, p = 0.02). Although reference lumen areas were similar in BMS and first- and second-generation DES, restenotic DES were longer (BMS 21.8 ± 13.5 mm, first-generation DES 29.4 ± 16.1 mm, second-generation DES 32.1 ± 18.7 mm, p = 0.003), and stent areas were smaller (BMS 7.2 ± 2.4 mm(2), first-generation DES 6.1 ± 2.1 mm(2), second-generation DES 5.7 ± 2.0 mm(2), p <0.001). Stent fracture was seen only in DES (first-generation DES 7 [5.0%], second-generation DES 8 [7.4%], p = 0.13). In conclusion, restenotic first- and second-generation DES were characterized by less neointimal hyperplasia, smaller stent areas, longer stent lengths, and more stent fractures than restenotic BMS. Copyright © 2015 Elsevier Inc. All rights reserved.
Surface acoustic wave actuated cell sorting (SAWACS).
Franke, T; Braunmüller, S; Schmid, L; Wixforth, A; Weitz, D A
2010-03-21
We describe a novel microfluidic cell sorter which operates in continuous flow at high sorting rates. The device is based on a surface acoustic wave cell-sorting scheme and combines many advantages of fluorescence activated cell sorting (FACS) and fluorescence activated droplet sorting (FADS) in microfluidic channels. It is fully integrated on a PDMS device, and allows fast electronic control of cell diversion. We direct cells by acoustic streaming excited by a surface acoustic wave which deflects the fluid independently of the contrast in material properties of deflected objects and the continuous phase; thus the device underlying principle works without additional enhancement of the sorting by prior labelling of the cells with responsive markers such as magnetic or polarizable beads. Single cells are sorted directly from bulk media at rates as fast as several kHz without prior encapsulation into liquid droplet compartments as in traditional FACS. We have successfully directed HaCaT cells (human keratinocytes), fibroblasts from mice and MV3 melanoma cells. The low shear forces of this sorting method ensure that cells survive after sorting.
NATO Human Resources (Manpower) Management (Gestion des ressources humaines (effectifs) de l’OTAN)
2012-02-01
performances , la gestion des récompenses et du salaire, et la motivation du personnel. En conséquence, il faut que la gestion des ressources humaines...importance au fil du temps. Les ressources humaines, chargées à l’origine de l’embauche, du licenciement, de la paie et de la gestion des ...les effets des systèmes d’évaluation des performances ;
1979-06-01
7 INTRODUCTION ...................................................................................... 12 CHAPITRE I : ELEMENTS DE DYNAMIQUE...daone Ie texts. 12 INTRODUCTION La ddtermination des ddrivdes adrodynamiques de stabilitd, en soufflerie et au tunnel de tir, aur des maquettes...ddtection des forces eat effectuds de fegon classiqus depuis plus de vingt ana par des barreaux d’acier dquipds de jauges de contrainte, gdndralament en
Electronic Messaging for the 90s (Les Messageries Electroniques des Annees 90)
1993-05-01
des autres unitds (un programme peut par exemple inclure un algorithme de 2. L CICULAIONDE ’INFRMAION recherche dans des donn~es...dit quc le rdseau, en particulier le r.dseau distant, cette coopdration homme /macbine. aifre des performances bien infirieures A celles des ordinateurs...dans ce sens, entre constructeurs d’ordinateurs, des opdrations traitementltransport. constructeurs didquipements de t~ l ~communications et exploitants de
Wright, Alice; Humphris, Gerry; Wanyonyi, Kristina L; Freeman, Ruth
2012-10-01
To show if cues, concerns and provider responses (defined in VR-CoDES and VR-CoDES-P manuals) are present, can be reliably coded and require additional advice for adoption in a dental context. Thirteen patients in a dental practice setting were videoed with either their dentist or hygienist and dental nurse present in routine treatment sessions. All utterances were coded using the Verona systems: VR-CoDES and the VR-CoDES-P. Rates of cue, concerns and provider responses described and reliability tested. The VR-CoDES and VR-CoDES-P were successfully applied in the dental context. The intra-rater ICCs for the detection of cues and concerns and provider response were acceptable and above 0.75. A similar satisfactory result was found for the inter-rater reliability. The VR-CoDES and the VR-CoDES-P are applicable in the dental setting with minor supporting guidelines and show evidence of reliable coding. The VR-CoDES and the VR-CoDES-P may be helpful tools for analysing patient cues and concerns and the dental professionals' responses in the dental context. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Research of grasping algorithm based on scara industrial robot
NASA Astrophysics Data System (ADS)
Peng, Tao; Zuo, Ping; Yang, Hai
2018-04-01
As the tobacco industry grows, facing the challenge of the international tobacco giant, efficient logistics service is one of the key factors. How to complete the tobacco sorting task of efficient economy is the goal of tobacco sorting and optimization research. Now the cigarette distribution system uses a single line to carry out the single brand sorting task, this article adopts a single line to realize the cigarette sorting task of different brands. Using scara robot special algorithm for sorting and packaging, the optimization scheme significantly enhances the indicators of smoke sorting system. Saving labor productivity, obviously improve production efficiency.
Learning Cellular Sorting Pathways Using Protein Interactions and Sequence Motifs
Lin, Tien-Ho; Bar-Joseph, Ziv
2011-01-01
Abstract Proper subcellular localization is critical for proteins to perform their roles in cellular functions. Proteins are transported by different cellular sorting pathways, some of which take a protein through several intermediate locations until reaching its final destination. The pathway a protein is transported through is determined by carrier proteins that bind to specific sequence motifs. In this article, we present a new method that integrates protein interaction and sequence motif data to model how proteins are sorted through these sorting pathways. We use a hidden Markov model (HMM) to represent protein sorting pathways. The model is able to determine intermediate sorting states and to assign carrier proteins and motifs to the sorting pathways. In simulation studies, we show that the method can accurately recover an underlying sorting model. Using data for yeast, we show that our model leads to accurate prediction of subcellular localization. We also show that the pathways learned by our model recover many known sorting pathways and correctly assign proteins to the path they utilize. The learned model identified new pathways and their putative carriers and motifs and these may represent novel protein sorting mechanisms. Supplementary results and software implementation are available from http://murphylab.web.cmu.edu/software/2010_RECOMB_pathways/. PMID:21999284
A New Algorithm Using the Non-Dominated Tree to Improve Non-Dominated Sorting.
Gustavsson, Patrik; Syberfeldt, Anna
2018-01-01
Non-dominated sorting is a technique often used in evolutionary algorithms to determine the quality of solutions in a population. The most common algorithm is the Fast Non-dominated Sort (FNS). This algorithm, however, has the drawback that its performance deteriorates when the population size grows. The same drawback applies also to other non-dominating sorting algorithms such as the Efficient Non-dominated Sort with Binary Strategy (ENS-BS). An algorithm suggested to overcome this drawback is the Divide-and-Conquer Non-dominated Sort (DCNS) which works well on a limited number of objectives but deteriorates when the number of objectives grows. This article presents a new, more efficient algorithm called the Efficient Non-dominated Sort with Non-Dominated Tree (ENS-NDT). ENS-NDT is an extension of the ENS-BS algorithm and uses a novel Non-Dominated Tree (NDTree) to speed up the non-dominated sorting. ENS-NDT is able to handle large population sizes and a large number of objectives more efficiently than existing algorithms for non-dominated sorting. In the article, it is shown that with ENS-NDT the runtime of multi-objective optimization algorithms such as the Non-Dominated Sorting Genetic Algorithm II (NSGA-II) can be substantially reduced.
Beiraghi, Asadollah; Shokri, Masood
2018-02-01
In the present study a new centrifuge-less dispersive liquid-liquid microextraction technique based on application of a new task specific magnetic polymeric ionic liquid (TSMPIL) as a chelating and extraction solvent for selective preconcentration of trace amounts of potassium from oil samples is developed, for the first time. After extraction, the fine droplets of TSMPIL were transferred into an eppendorf tube and diluted to 500µL using distilled water. Then, the enriched analyte was determined by flame atomic emission spectroscopy (FAES). Several important factors affecting both the complexation and extraction efficiency including extraction time, rate of vortex agitator, amount of carbonyl iron powder, pH of sample solution, volume of ionic liquid as well as effects of interfering species were investigated and optimized. Under the optimal conditions, the limits of detection (LOD) and quantification (LOQ) were 0.5 and 1.6µgL -1 respectively with the preconcentration factor of 128. The precision (RSD %) for seven replicate determinations at 10µgL -1 of potassium was better than 3.9%. The relative recoveries for the spiked samples were in the acceptable range of 95-104%. The results demonstrated that no remarkable interferences are created by other various ions in the determination of potassium, so that the tolerance limits (W Ion /W K ) of major cations and anions were in the range of 2500-10,000. The purposed method was successfully applied for the analysis of potassium in some oil samples. Copyright © 2017 Elsevier B.V. All rights reserved.
Multiplexed electrokinetic sample fractionation, preconcentration and elution for proteomics.
Hua, Yujuan; Jemere, Abebaw B; Dragoljic, Jelena; Harrison, D Jed
2013-07-07
Both 6 and 8-channel integrated microfluidic sample pretreatment devices capable of performing "in space" sample fractionation, collection, preconcentration and elution of captured analytes via sheath flow assisted electrokinetic pumping are described. Coatings and monolithic polymer beds were developed for the glass devices to provide cationic surface charge and anodal electroosmotic flow for delivery to an electrospray emitter tip. A mixed cationic ([2-(methacryloyloxy)ethyl] trimethylammonium chloride) (META) and hydrophobic butyl methacrylate-based monolithic porous polymer, photopolymerized in the 6- or 8-fractionation channels, was used to capture and preconcentrate samples. A 0.45 wt% META loaded bed generated comparable anodic electroosmotic flow to the cationic polymer PolyE-323 coated channel segments in the device. The balanced electroosmotic flow allowed stable electrokinetic sheath flow to prevent cross contamination of separated protein fractions, while reducing protein/peptide adsorption on the channel walls. Sequential elution of analytes trapped in the SPE beds revealed that the monolithic columns could be efficiently used to provide sheath flow during elution of analytes, as demonstrated for neutral carboxy SNARF (residual signal, 0.08% RSD, n = 40) and charged fluorescein (residual signal, 2.5% n = 40). Elution from monolithic columns showed reproducible performance with peak area reproducibility of ~8% (n = 6 columns) in a single sequential elution and the run-to-run reproducibility was 2.4-6.7% RSD (n = 4) for elution from the same bed. The demonstrated ability of this device design and operation to elute from multiple fractionation beds into a single exit channel for sample analysis by fluorescence or electrospray mass spectrometry is a crucial component of an integrated fractionation and assay system for proteomics.
Khani, Rouhollah; Ghasemi, Jahan B; Shemirani, Farzaneh
2014-03-25
A powerful and efficient signal-preprocessing technique that combines local and multiscale properties of the wavelet prism with the global filtering capability of orthogonal signal correction (OSC) is applied for pretreatment of spectroscopic data of parabens as model compounds after their preconcentration by robust ionic liquid-based dispersive liquid-liquid microextraction method (IL-DLLME). In the proposed technique, a mixture of a water-immiscible ionic liquid (as extraction solvent) [Hmim][PF6] and disperser solvent is injected into an aqueous sample solution containing one of the IL's ions, NaPF6, as extraction solvent and common ion source. After preconcentration, the absorbance of the extracted compounds was measured in the wavelength range of 200-700 nm. The wavelet orthogonal signal correction with partial least squares (WOSC-PLS) method was then applied for simultaneous determination of each individual compound. Effective parameters, such as amount of IL, volume of the disperser solvent and amount of NaPF6, were inspected by central composite design to identify the most important parameters and their interactions. The effect of pH on the sensitivity and selectivity was studied according to the net analyte signal (NAS) for each component. Under optimum conditions, enrichment factors of the studied compounds were 75 for methyl paraben (MP) and 71 for propyl paraben (PP). Limits of detection for MP and PP were 4.2 and 4.8 ng mL(-)(1), respectively. The root mean square errors of prediction for MP and PP were 0.1046 and 0.1275 μg mL(-)(1), respectively. The practical applicability of the developed method was examined using hygienic, cosmetic, pharmaceutical and natural water samples. Copyright © 2013 Elsevier B.V. All rights reserved.
Martínez, Noelia A; Pereira, Sirley V; Bertolino, Franco A; Schneider, Rudolf J; Messina, Germán A; Raba, Julio
2012-04-20
The synthetic estrogen ethinylestradiol (EE2) is an active component of oral contraceptives (OCs), considered as an endocrine disrupting compound (EDC). It is excreted from humans and released via sewage treatment plant effluents into aquatic environments. EDCs are any environmental pollutant chemical that, once incorporated into an organism, affects the hormonal balance of various species including humans. Its presence in the environment is becoming of great importance in water quality. This paper describes the development of an accurate, sensitive and selective method for capture, preconcentration and determination of EE2 present in water samples using: magnetic particles (MPs) as bioaffinity support for the capture and preconcentration of EE2 and a glassy carbon electrode modified with multi-walled carbon nanotubes (MWCNTs/GCE) as detection system. The capture procedure was based on the principle of immunoaffinity, the EE2 being extracted from the sample using the anti-EE2 antibodies (anti-EE2 Ab) which were previously immobilized on MPs. Subsequently the analyte desorption was done employing a sulfuric acid solution and the determination of the EE2 in the pre-concentrated solution was carried out by square wave voltammetry (SWV). This method can be used to determine EE2 in the range of 0.035-70 ng L(-1) with a detection limit (LOD) of 0.01 ng L(-1) and R.S.D.<4.20%. The proposed method has been successfully applied to the determination of EE2 in water samples and it has promising analytical applications for the direct determination of EE2 at trace levels. Copyright © 2012 Elsevier B.V. All rights reserved.
Varbanova, Evelina K; Angelov, Plamen A; Stefanova, Violeta M
2016-11-01
In the present work the potential of a new ligand 3-Ethylamino-but-2-enoic acid phenylamide (representing the class of enaminones) for selective preconcentration of lanthanides (La, Ce, Eu, Gd and Er) from aqueous medium is examined. Liquid-liquid extraction parameters, such as pH of the water phase, type and volume of organic solvent, quantity of ligand and reaction time are optimized on model solutions. Recovery of lanthanides by re-extraction with nitric acid makes the LLE procedure compatible with Inductively Coupled Plasma Mass Spectrometry. Spectral and non-spectral interferences are studied. Two isotopes per element are measured (with exception of La) for dynamic evaluation of the potential risk of spectral interference in variable real samples. The selectivity of complex formation reaction towards concomitant alkali and alkali-earth elements eliminates the interferences from sample matrix. Subjecting the standards to the optimized extraction procedure in combination with Re as internal standard is recommended as calibration strategy. The accuracy of developed method is approved by analysis of CRM Bush branches and leaves (NCS DC 73348) and recovery of spiked water and plant samples. The method's limits of detection for both studied objects are in the ranges from 0.2 ((158)Gd) to 3.7 ((139)La) ngl(-1) and 0.02 ((158)Gd) to 0.37((139)La) ngg(-1) for waters and plants respectively. The studied compound is an effective new ligand for preconcentration/separation of lanthanides from aqueous medium by LLE and subsequent determination by ICP-MS. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Kuo, C.-Y.; Chen, P.-S.; Chen, H.-T.; Lu, C.-J.; Tian, W.-C.
2017-03-01
In this study, a simple process for fabricating a novel micromachined preconcentrator (μPCT) and a gas chromatographic separation column (μSC) for use in a micro gas chromatograph (μGC) using one photomask is described. By electroless gold plating, a high-surface-area gold layer was deposited on the surface of channels inside the μPCT and μSC. For this process, (3-aminopropyl) trimethoxysilane (APTMS) was used as a promoter for attaching gold nanoparticles on a silicon substrate to create a seed layer. For this purpose, a gold sodium sulfite solution was used as reagent for depositing gold to form heating structures. The microchannels of the μPCT and μSC were coated with the adsorbent and stationary phase, Tenax-TA and polydimethylsiloxane (DB-1), respectively. μPCTs were heated at temperatures greater than 280 °C under an applied electrical power of 24 W and a heating rate of 75 °C s-1. Repeatable thermal heating responses for μPCTs were achieved; good linearity (R 2 > 0.9997) was attained at three heating rates for the temperature programme for the μSC (0.2, 0.5 and 1 °C s-1). The volatile organic compounds (VOCs) toluene and m-xylene were concentrated over the μPCT by rapid thermal desorption (peak width of half height (PWHH) <1.5 s) preconcentration factors for both VOCs are >7900. The VOCs acetone, benzene, toluene, m-xylene and 1,3,5-trimethylbenzene were also separated on the μSC as evidenced by their different retention times (47-184 s).
Pashaei, Yaser; Ghorbani-Bidkorbeh, Fatemeh; Shekarchi, Maryam
2017-05-26
In the present study, superparamagnetic graphene oxide-Fe 3 O 4 nanocomposites were successfully prepared by a modified impregnation method (MGO mi ) and their application as a sorbent in the magnetic-dispersive solid phase extraction (M-dSPE) mode to the preconcentration and determination of tamsulosin hydrochloride (TMS) in human plasma was investigated by coupling with high performance liquid chromatography-ultraviolet detection (HPLC-UV). The structure, morphology and magnetic properties of the prepared nanocomposites were characterized using X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), and vibrating sample magnetometry (VSM). Some factors affecting the extraction efficiency, including the pH value, amount of sorbent, extraction time, elution solvent and its volume, and desorption time were studied and optimized. Magnetic nanocomposites plasma extraction of TMS following HPLC analyses showed a linear calibration curve in the range of 0.5-50.0ngmL -1 with an acceptable correlation coefficient (R 2 =0.9988). The method was sensitive, with a low limit of detection (0.17ngmL -1 ) and quantification (0.48ngmL -1 ). Inter- and intra-day precision expressed as relative standard deviation (n=3) and the preconcentration factor, were found to be 5.6-7.2%, 2.9-4.2% and 10, respectively. Good recoveries (98.1-101.4%) with low relative standard deviations (4.2-5.0%) indicated that the matrices under consideration do not significantly affect the extraction process. Due to its high precision and accuracy, the developed method may be a HPLC-UV alternative with M-dSPE for bioequivalence analysis of TMS in human plasma. Copyright © 2017 Elsevier B.V. All rights reserved.
Razi-Asrami, Mahboobeh; Ghasemi, Jahan B; Amiri, Nayereh; Sadeghi, Seyed Jamal
2017-04-01
In this paper, a simple, fast, and inexpensive method is introduced for the simultaneous spectrophotometric determination of crystal violet (CV) and malachite green (MG) contents in aquatic samples using partial least squares regression (PLS) as a multivariate calibration technique after preconcentration by graphene oxide (GO). The method was based on the sorption and desorption of analytes onto GO and direct determination by ultraviolet-visible spectrophotometric techniques. GO was synthesized according to Hummers method. To characterize the shape and structure of GO, FT-IR, SEM, and XRD were used. The effective factors on the extraction efficiency such as pH, extraction time, and the amount of adsorbent were optimized using central composite design. The optimum values of these factors were 6, 15 min, and 12 mg, respectively. The maximum capacity of GO for the adsorption of CV and MG was 63.17 and 77.02 mg g -1 , respectively. Preconcentration factors and extraction recoveries were obtained and were 19.6, 98% for CV and 20, 100% for MG, respectively. LOD and linear dynamic ranges for CV and MG were 0.009, 0.03-0.3, 0.015, and 0.05-0.5 (μg mL -1 ), respectively. The intra-day and inter-day relative standard deviations were 1.99 and 0.58 for CV and 1.69 and 3.13 for MG at the concentration level of 50 ng mL -1 , respectively. Finally, the proposed DSPE/PLS method was successfully applied for the simultaneous determination of the trace amount of CV and MG in the real water samples.
NASA Astrophysics Data System (ADS)
Chen, Shizhong; Zhu, Shengping; Lu, Dengbo
2018-01-01
A method was developed for speciation analysis of antimony by electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS) after preconcentration/separation using dispersive micro-solid phase extraction (DMSPE) and dispersive liquid-liquid micro-extraction (DLLME). In DMSPE, titanium dioxide nanofibers were used for preconcentration and separation of analytes. The upper aqueous phase and elution solution from DMSPE were used for further preconcentration and separation of Sb(III) and Sb(V) by DLLME without any pre-oxidation or pre-reduction operation, respectively. The extracts from DLLME were used for ETV-ICP-MS determination with APDC as a chemical modifier. Under optimal conditions, the detection limits of this method were 0.019 and 0.025 pg mL- 1 with relative standard deviations of 5.7% and 6.9% for Sb(III) and Sb(V) (c = 1.0 ng mL- 1, n = 9), respectively. This method was applied for speciation analysis of Sb and its distribution in the tea leaves and the tea infusion, including total, suspended, soluble, organic and inorganic Sb as well as Sb(III) and Sb(V). The results showed that the contents of Sb are 62.7, 12.9 and 47.3 ng g- 1 in the tea leaves, tea residue and tea soup, respectively; those of soluble, organic, inorganic, Sb(III) and Sb(V) are 0.41, 0.11, 0.29, 0.21 and 0.07 ng mL- 1 in the tea soup, respectively. A certified reference material of tea leaves (GBW 07605) was analyzed by this method with satisfactory results.
Yang, Xiupei; Jia, Zhihui; Yang, Xiaocui; Li, Gu; Liao, Xiangjun
2017-03-01
A cloud point extraction (CPE) method was used as a pre-concentration strategy prior to the determination of trace levels of silver in water by flame atomic absorption spectrometry (FAAS) The pre-concentration is based on the clouding phenomena of non-ionic surfactant, triton X-114, with Ag (I)/diethyldithiocarbamate (DDTC) complexes in which the latter is soluble in a micellar phase composed by the former. When the temperature increases above its cloud point, the Ag (I)/DDTC complexes are extracted into the surfactant-rich phase. The factors affecting the extraction efficiency including pH of the aqueous solution, concentration of the DDTC, amount of the surfactant, incubation temperature and time were investigated and optimized. Under the optimal experimental conditions, no interference was observed for the determination of 100 ng·mL -1 Ag + in the presence of various cations below their maximum concentrations allowed in this method, for instance, 50 μg·mL -1 for both Zn 2+ and Cu 2+ , 80 μg·mL -1 for Pb 2+ , 1000 μg·mL -1 for Mn 2+ , and 100 μg·mL -1 for both Cd 2+ and Ni 2+ . The calibration curve was linear in the range of 1-500 ng·mL -1 with a limit of detection (LOD) at 0.3 ng·mL -1 . The developed method was successfully applied for the determination of trace levels of silver in water samples such as river water and tap water.
Sricharoen, Phitchan; Limchoowong, Nunticha; Areerob, Yonrapach; Nuengmatcha, Prawit; Techawongstien, Suchila; Chanthai, Saksit
2017-07-01
Fe 3 O 4 /hydroxyapatite/graphene quantum dots (Fe 3 O 4 /HAP/GQDs) nanocomposite was synthesized and used as a novel magnetic adsorbent. This nanocomposite was characterized using scanning electron microscopy, transmission electron microscopy, Fourier transform infrared spectroscopy, X-ray diffraction, energy dispersive X-ray spectroscopy, and magnetization property. The Fe 3 O 4 /HAP/GQDs was applied to pre-concentrate copper residues in Thai food ingredients (so-called "Tom Yum Kung") prior to determination by inductively coupled plasma-atomic emission spectrometry. Based on ultrasound-assisted extraction optimization, various parameters affecting the magnetic solid-phase extraction, such as solution pH, amount of magnetic nanoparticles, adsorption and desorption time, and type of elution solvent and its concentration were evaluated. Under optimal conditions, the linear range was 0.05-1500ngmL -1 (R 2 >0.999), limit of detection was 0.58ngmL -1 , and limit of quantification was 1.94ngmL -1 . The precision, expressed as the relative standard deviation of the calibration curve slope (n=5), for intra-day and inter-day analyses was 0.87% and 4.47%, respectively. The recovery study of Cu for real samples was ranged between 83.5% and 104.8%. This approach gave the enrichment factor of 39.2, which guarantees trace analysis of Cu residues. Therefore, Fe 3 O 4 /HAP/GQDs can be a potential and suitable candidate for the pre-concentration and separation of Cu from food samples. It can easily be reused after treatment with deionized water. Copyright © 2017 Elsevier B.V. All rights reserved.
Mehrabi, Fatemeh; Vafaei, Azam; Ghaedi, Mehrorang; Ghaedi, Abdol Mohammad; Alipanahpour Dil, Ebrahim; Asfaram, Arash
2017-09-01
In this research, a selective, simple and rapid ultrasound assisted dispersive solid-phase micro-microextraction (UA-DSPME) was developed using cobalt ferrite nanoparticles loaded on activated carbon (CoFe 2 O 4 -NPs-AC) as an efficient sorbent for the preconcentration and determination of Maxilon Red GRL (MR-GRL) dye. The properties of sorbent are characterized by X-ray diffraction (XRD), Transmission Electron Microscopy (TEM), Vibrating sample magnetometers (VSM), Fourier transform infrared spectroscopy (FTIR), Particle size distribution (PSD) and Scanning Electron Microscope (SEM) techniques. The factors affecting on the determination of MR-GRL dye were investigated and optimized by central composite design (CCD) and artificial neural networks based on genetic algorithm (ANN-GA). CCD and ANN-GA were used for optimization. Using ANN-GA, optimum conditions were set at 6.70, 1.2mg, 5.5min and 174μL for pH, sorbent amount, sonication time and volume of eluent, respectively. Under the optimized conditions obtained from ANN-GA, the method exhibited a linear dynamic range of 30-3000ngmL -1 with a detection limit of 5.70ngmL -1 . The preconcentration factor and enrichment factor were 57.47 and 93.54, respectively with relative standard deviations (RSDs) less than 4.0% (N=6). The interference effect of some ions and dyes was also investigated and the results show a good selectivity for this method. Finally, the method was successfully applied to the preconcentration and determination of Maxilon Red GRL in water and wastewater samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Li, Zhenhua; Chang, Xijun; Zou, Xiaojun; Zhu, Xiangbing; Nie, Rong; Hu, Zheng; Li, Ruijun
2009-01-26
A new method that utilizes ethylenediamine-modified activated carbon (AC-EDA) as a solid-phase extractant has been developed for simultaneous preconcentration of trace Cr(III), Fe(III), Hg(II) and Pb(II) prior to the measurement by inductively coupled plasma optical emission spectrometry (ICP-OES). The new sorbent was prepared by oxidative surface modification. Experimental conditions for effective adsorption of trace levels of Cr(III), Fe(III), Hg(II) and Pb(II) were optimized with respect to different experimental parameters using batch and column procedures in detail. The optimum pH value for the separation of metal ions simultaneously on the new sorbent was 4.0. Complete elution of absorbed metal ions from the sorbent surface was carried out using 3.0 mL of 2% (%w/w) thiourea and 0.5 mol L(-1) HCl solution. Common coexisting ions did not interfere with the separation and determination of target metal ions. The maximum static adsorption capacity of the sorbent at optimum conditions was found to be 39.4, 28.9, 60.5 and 49.9 mg g(-1) for Cr(III), Fe(III), Hg(II) and Pb(II), respectively. The time for 94% adsorption of target metal ions was less than 2 min. The detection limits of the method was found to be 0.28, 0.22, 0.09 and 0.17 ng mL(-1) for Cr(III), Fe(III), Hg(II) and Pb(II), respectively. The precision (R.S.D.) of the method was lower 4.0% (n=8). The prepared sorbent as solid-phase extractant was successfully applied for the preconcentration of trace Cr(III), Fe(III), Hg(II) and Pb(II) in natural and certified samples with satisfactory results.
Salih, Bekir; Celikbiçak, Omür; Döker, Serhat; Doğan, Mehmet
2007-03-28
Poly(N-(hydroxymethyl)methacrylamide)-1-allyl-2-thiourea) hydrogels, poly(NHMMA-ATU), were synthesized by gamma radiation using (60)Co gamma source in the ternary mixture of NHMMA-ATU-H(2)O. These hydrogels were used for the specific gold, silver, platinum and palladium recovery, pre-concentration and matrix elimination from the solutions containing trace amounts of precious metal ions. Elimination of inorganic matrices such as different transition and heavy metal ions, and anions was performed by adjusting the solution pH to 0.5 that was the selective adsorption pH of the precious metal ions. Desorption of the precious metal ions was performed by using 0.8 M thiourea in 3M HCl as the most efficient desorbing agent with recovery values more than 95%. In the desorption medium, thiourea effect on the atomic signal was eliminated by selecting proper pyrolysis and atomization temperatures for all precious metal ions. Precision and the accuracy of the results were improved in the graphite furnace-atomic absorption spectrometer (GFAAS) measurements by applying the developed matrix elimination method performing the adsorption at pH 0.5. Pre-concentration factors of the studied precious metal ions were found to be at least 1000-fold. Detection limits of the precious metal ions were found to be less than 10 ng L(-1) of the all studied precious metal ions by using the proposed pre-concentration method. Determination of trace levels of the precious metals in the sea-water, anode slime, geological samples and photographic fixer solutions were performed using GFAAS clearly after applying the adsorption-desorption cycle onto the poly(NHMMA-UTU) hydrogels.
Roohparvar, Rasool; Taher, Mohammad Ali; Mohadesi, Alireza
2008-01-01
For the simultaneous determination of nickel(ll) and copper(ll) in plant samples, a rapid and accurate method was developed. In this method, solid-phase extraction (SPE) and first-order derivative spectrophotometry (FDS) are combined, and the result is coupled with the H-point standard addition method (HPSAM). Compared with normal spectrophotometry, derivative spectrophotometry offers the advantages of increased selectivity and sensitivity. As there is no need for carrying out any pretreatment of the sample, the spectrophotometry method is easy, but because of a high detection limit, it is not so practical. In order to decrease the detection limit, it is suggested to combine spectrophotometry with a preconcentration method such as SPE. In the present work, after separation and preconcentration of Ni(ll) and Cu(ll) on modified clinoptilolite zeolite that is loaded with 2-[1-(2-hydroxy-5-sulforphenyl)-3-phenyl-5-formaza-no]-benzoic acid monosodium salt (zincon) as a selective chromogenic reagent, FDS-HPSAM, which is a simple and selective spectrophotometric method, has been applied for simultaneous determination of these ions. With optimum conditions, the detection limit in original solutions is 0.7 and 0.5 ng/mL, respectively, for nickel and copper. The linear concentration ranges in the proposed method for nickel and copper ions in original solutions are 1.1 to 3.0 x 10(3) and 0.9 to 2.0 x 10(3) ng/mL, respectively. The recommended procedure is applied to successful determination of Cu(ll) and Ni(ll) in standard and real samples.
Segade, Susana Río; Tyson, Julian F
2007-03-15
A novel method for preconcentration of methylmercury and inorganic mercury from water samples was developed involving the determination of ngl(-1) levels of analytes retained on the silica C(18) solid sorbent, previous complexation with ammonium pyrrolidine dithiocarbamate (APDC), by slurry sampling cold vapor atomic absorption spectrometry (SS-CVAAS) in a flow injection (FI) system. Several variables were optimized affecting either the retention of both mercury species, such as APDC concentration, silica C(18) amount, agitation times, or their determination, including hydrochloric acid concentration in the suspension medium, peristaltic pump speed and argon flow-rate. A Plackett-Burman saturated factorial design permitted to differentiate the influential parameters on the preconcentration efficiency, which were after optimized by the sequential simplex method. The contact time between mercury containing solution and APDC, required to reach an efficient sorption, was decreased from 26 to 3min by the use of sonication stirring instead of magnetic stirring. The use of 1moldm(-3) hydrochloric acid suspension medium and 0.75% (m/v) sodium borohydride reducing agent permitted the selective determination of methylmercury. The combination of 5moldm(-3) hydrochloric acid and 10(-4)% (m/v) sodium borohydride was used for the selective determination of inorganic mercury. The detection limits achieved for methylmercury and inorganic mercury determination under optimum conditions were 0.96 and 0.25ngl(-1), respectively. The reliability of the proposed method for the determination of both mercury species in waters was checked by the analysis of samples spiked with known concentrations of methylmercury and inorganic mercury; quantitative recoveries were obtained.
Moret, Sònia; Sánchez, Juan M; Salvadó, Victòria; Hidalgo, Manuela
2005-12-16
A procedure using alkaline extraction, solid-phase extraction (SPE) and HPLC is developed to analyze the polar herbicides 2,4-dichlorophenoxyacetic acid (2,4-D) and 4-chloro-2-methylphenoxyacetic acid (MCPA) together with their main metabolites in soils. An ion-pairing HPLC method is used for the determination as it permits the baseline separation of these highly polar herbicides and their main metabolites. The use of a highly cross-linked polystyrene-divinylbenzene sorbent (PS-DVB) gives the best results for the analysis of these compounds. This sorbent allows the direct preconcentration of the analytes at the high pH values obtained after quantitative alkaline extraction of the herbicides from soil samples. Different parameters are evaluated for the SPE preconcentration step. The high polarity of the main analytes of interest (2,4-D and MCPA) makes it necessary to work at low flow rates (< or =0.5 mL min(-1)) in order for these compounds to be retained by the PS-DVB sorbent. A two stage desorption from the SPE sorbent is required to obtain the analytes in solvents that are appropriate for HPLC determination. A first desorption with a 50:50 methanol:water mixture elutes the most polar analytes (2,4-D, MCPA and 2CP). The second elution step with methanol permits the analysis of the other phenol derivatives. The humic and fulvic substances present in the soil are not efficiently retained by PS-DVB sorbents at alkaline pH's and so do not interfere in the analysis. This method has been successfully applied in the analysis of soil samples from a golf course treated with a commercial product containing esters of 2,4-D and MCPA as the active components.
Silva, Mariana; Morante-Zarcero, Sonia; Pérez-Quintanilla, Damián; Marina, María Luisa; Sierra, Isabel
2017-08-01
A method for simultaneous separation and determination of four enantiomeric pairs of β-blockers in waters by chiral CE has been developed. Off-line SPE was employed using functionalized ordered mesoporous silica as sorbent. Separation by CE was achieved using a BGE composed by methylated-β-CD (1.25% w/v) dissolved in a 50 mM phosphate buffer (pH 2.5) and 30°C, with good chiral resolution for all enantiomers. Mesoporous silica functionalized with octadecyl groups (denoted SBA15-C18) was prepared by a postsynthesis method and applied for the preconcentration of atenolol, propranolol, metoprolol, and pindolol enantiomers in waters by off-line SPE. Under optimized conditions, a preconcentration factor of 300 was achieved, employing 100 mg of SBA15-C18 as sorbent, with recoveries between 96 and 105% in tap water and good repeatability (% RSD = 7-11%, n = 6). Commercial C18 amorphous silica (ExtraBond R C 18 ) was also tested as sorbent for SPE, but results revealed better extraction capacity with higher recoveries for the SBA15-C18 material. The analytical characteristics of the off-line SPE-chiral CE method were evaluated, showing good precision, linearity, and accuracy with method quantification limits between 5.3 and 13.7 μg/L for all enantiomers. The SBA15-C18 material allowed the extraction of four enantiomeric pairs of β-blockers spiked in tap water, river water, and ground water with recoveries between 58 and 105%. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Baytak, Sıtkı; Arslan, Zikri
2015-01-01
This study presents a simple, robust and environmentally friendly solid phase preconcentration procedure for multielement determination by inductively coupled plasma optical emission spectrometry (ICP-OES) using diphenylcarbazone (DPC) impregnated TiO2 nanopowder (n-TiO2). DPC was successfully impregnated onto n-TiO2 in colloidal solution. A number of elements, including Co(II), Cr(III), Cu(II), Fe(III), Mn(II) and Zn(II) were quantitatively preconcentrated from aqueous solutions between pH 8 and 8.5 at a flow rate of 2 mL min−1, and then eluted with 2 mL of 5% (v/v) HNO3. A mini-column packed with 0.12 g DPC impregnated n-TiO2 retained all elements quantitatively from up to 250 mL multielement solution (2.5 μg per analyte) affording an enrichment factor of 125. The limits of detection (LOD) for preconcentration of 50 mL blank solutions (n = 12) were 0.28, 0.15, 0.25, 0.22, 0.12, and 0.10 μg L−1 for Co, Cr, Cu, Fe, Mn, and Zn, respectively. The relative standard deviation (RSD) for five replicate determinations was 0.8, 3.4, 2.6, 2.2, 1.2 and 3.3% for Co, Cr, Cu, Fe, Mn and Zn, respectively, at 5 μg L−1 level. The method was validated with analysis of Freshwater (SRM 1643e) and Lobster hepatopancreas (TORT-2) certified reference materials, and then applied to the determination of the elements from tap water and lake water samples by ICP-OES. PMID:26236403
Søndergaard, Jens; Asmund, Gert; Larsen, Martin M.
2015-01-01
Trace element determination in seawater is analytically challenging due to the typically very low concentrations of the trace elements and the potential interference of the salt matrix. A common way to address the challenge is to pre-concentrate the trace elements on a chelating resin, then rinse the matrix elements from the resin and subsequently elute and detect the trace elements using inductively coupled plasma mass spectrometry (ICP-MS). This technique typically involves time-consuming pre-treatment of the samples for ‘off-line’ analyses or complicated sample introduction systems involving several pumps and valves for ‘on-line’ analyses. As an alternative, the following method offers a simple method for ‘on-line’ analyses of seawater by ICP-MS. As opposed to previous methods, excess seawater was pumped through the nebulizer of the ICP-MS during the pre-concentration step but the gas flow was adjusted so that the seawater was pumped out as waste without being sprayed into the instrument. Advantages of the method include: • Simple and convenient analyses of seawater requiring no changes to the ‘standard’ sample introduction system except from a resin-filled micro-column connected to the sample tube. The ‘standard’ sample introduction system refers to that used for routine digest-solution analyses of biota and sediment by ICP-MS using only one peristaltic pump; and • Accurate determination of the elements V, Mn, Co, Ni, Cu, Zn, Cd and Pb in a range of different seawater matrices verified by participation in 6 successive rounds of the international laboratory intercalibration program QUASIMEME. PMID:26258050
NASA Astrophysics Data System (ADS)
Aurousseau, Emmanuelle
Les modeles sont des outils amplement utilises en sciences et technologies (S&T) afin de representer et d’expliquer un phenomene difficilement accessible, voire abstrait. La demarche de modelisation est presentee de maniere explicite dans le programme de formation de l’ecole quebecoise (PFEQ), notamment au 2eme cycle du secondaire (Quebec. Ministere de l'Education du Loisir et du Sport, 2007a). Elle fait ainsi partie des sept demarches auxquelles eleves et enseignants sont censes recourir. Cependant, de nombreuses recherches mettent en avant la difficulte des enseignants a structurer leurs pratiques d’enseignement autour des modeles et de la demarche de modelisation qui sont pourtant reconnus comme indispensables. En effet, les modeles favorisent la conciliation des champs concrets et abstraits entre lesquels le scientifique, meme en herbe, effectue des allers-retours afin de concilier le champ experimental de reference qu’il manipule et observe au champ theorique relie qu’il construit. L’objectif de cette recherche est donc de comprendre comment les modeles et la demarche de modelisation contribuent a faciliter l’articulation du concret et de l’abstrait dans l’enseignement des sciences et des technologies (S&T) au 2eme cycle du secondaire. Pour repondre a cette question, nous avons travaille avec les enseignants dans une perspective collaborative lors de groupes focalises et d’observation en classe. Ces dispositifs ont permis d’examiner les pratiques d’enseignement que quatre enseignants mettent en oeuvre en utilisant des modeles et des demarches de modelisation. L’analyse des pratiques d’enseignement et des ajustements que les enseignants envisagent dans leur pratique nous permet de degager des connaissances a la fois pour la recherche et pour la pratique des enseignants, au regard de l’utilisation des modeles et de la demarche de modelisation en S&T au secondaire.
Effets des electrons secondaires sur l'ADN
NASA Astrophysics Data System (ADS)
Boudaiffa, Badia
Les interactions des electrons de basse energie (EBE) representent un element important en sciences des radiations, particulierement, les sequences se produisant immediatement apres l'interaction de la radiation ionisante avec le milieu biologique. Il est bien connu que lorsque ces radiations deposent leur energie dans la cellule, elles produisent un grand nombre d'electrons secondaires (4 x 104/MeV), qui sont crees le long de la trace avec des energies cinetiques initiales bien inferieures a 20 eV. Cependant, il n'y a jamais eu de mesures directes demontrant l'interaction de ces electrons de tres basse energie avec l'ADN, du principalement aux difficultes experimentales imposees par la complexite du milieu biologique. Dans notre laboratoire, les dernieres annees ont ete consacrees a l'etude des phenomenes fondamentaux induits par impact des EBE sur differentes molecules simples (e.g., N2, CO, O2, H2O, NO, C2H 4, C6H6, C2H12) et quelques molecules complexes dans leur phase solide. D'autres travaux effectues recemment sur des bases de l'ADN et des oligonucleotides ont montre que les EBE produisent des bris moleculaires sur les biomolecules. Ces travaux nous ont permis d'elaborer des techniques pour mettre en evidence et comprendre les interactions fondamentales des EBE avec des molecules d'interet biologique, afin d'atteindre notre objectif majeur d'etudier l'effet direct de ces particules sur la molecule d'ADN. Les techniques de sciences des surfaces developpees et utilisees dans les etudes precitees peuvent etre etendues et combinees avec des methodes classiques de biologie pour etudier les dommages de l'ADN induits par l'impact des EBE. Nos experiences ont montre l'efficacite des electrons de 3--20 eV a induire des coupures simple et double brins dans l'ADN. Pour des energies inferieures a 15 eV, ces coupures sont induites par la localisation temporaire d'un electron sur une unite moleculaire de l'ADN, ce qui engendre la formation d'un ion negatif transitoire dans un etat electronique dissociatif, cette localisation est suivie d'une fragmentation. A plus haute energie, la dissociation dipolaire (i.e., la formation simultanee d'un ion positif et negatif) et l'ionisation jouent un role important dans le dommage de l'ADN. L'ensemble de nos resultats permet d'expliquer les mecanismes de degradation de l'ADN par les EBE et d'obtenir des sections efficaces effectives des differents types de dommages.
Belaid, Loubna; Cloos, Patrick; Ridde, Valéry
2017-04-20
Cette étude vise à décrire la mobilisation des représentations ethnoculturelles par des agents et des gestionnaires de santé pour expliquer l'échec partiel d'une politique de santé maternelle et discuter des conséquences potentielles de ces représentations sur l'accès aux soins de santé des populations.MÉTHODES : Il s'agit d'une recherche qualitative de type socio-anthropologique mobilisant des entretiens approfondis, des discussions informelles, des observations non participantes menées dans les centres de santé et une analyse documentaire. Les entretiens ont été menés auprès de 16 agents de santé et de 10 gestionnaires. Les entretiens ont été enregistrés sous support numérique et transcrits. L'étude s'est déroulée dans le district sanitaire de Djibo au Burkina Faso.RÉSULTATS : L'identification ethnique, les coutumes relatives à l'accouchement (pudeur, discrétion, présence féminine), le statut social des femmes (le faible pouvoir décisionnel), le nomadisme et l'organisation sociale des populations et leurs résistances au changement sont érigés comme des obstacles « culturels » à la politique de santé. L'usage largement répandu de ces représentations par les agents et les gestionnaires de santé contribue à réprimander les populations et à masquer les facteurs structurels qui ont pourtant une influence plus importante sur l'utilisation des services de santé maternelle. Cette recherche met en lumière le danger de l'usage excessif des représentations ethnoculturelles teintées de culturalisme dans les pratiques et les politiques de santé publique en véhiculant des stéréotypes à l'égard de certains groupes de population. Pour comprendre le succès ou l'échec des politiques sanitaires, il demeure important de considérer la qualité du contact avec le système de santé, les facteurs structurels notamment les capacités des ménages à faire face aux dépenses des soins de santé et des distances entre les villages et les centres de santé. Ces éléments permettraient de mieux comprendre les disparités constatées à l'égard des indicateurs d'utilisation des services de santé.
ERIC Educational Resources Information Center
van Zundert, Danielle
1986-01-01
Describes an experiment in teaching language to young children through nature study. Activities are outlined, including the linguistic, cognitive, and cultural objectives for each. Brief illustrated descriptions are also given. (MSE)
US Army Morale, Welfare and Recreation (MWR) Programmes : Links to Readiness and Retention
2011-01-01
la Direction des opérations, Bureau du sous-chef d’état-major pour la ... gestion des emprises et garnisons de l’US Army, Washington, DC. Il enseigne au Département de philosophie du Northern Virginia Community College...américaine à l’intention des personnels militaires et des familles, et des variables mesurant l’état de préparation des forces et la fidélisation de
1996-04-01
regulations. - Ceratitis capitata (Mediterranean fruit fly). Quarantine regulations generally reduce - Rhagoletis pomonella (Apple maggot). the chances of a...d’insectes nuisibles dans un pays, en 6vitant des risques pour la sant6 des 6quipages, pour la s~curit6 de 1’a~ronef et pour l’industrie. Ce rapport examine 1...diffrrents officiels responsables de la r~glementation des insectes nuisibles introduits, de l’inscription des pesticides et de leur utilisation en
Particle Transport and Size Sorting in Bubble Microstreaming Flow
NASA Astrophysics Data System (ADS)
Thameem, Raqeeb; Rallabandi, Bhargav; Wang, Cheng; Hilgenfeldt, Sascha
2014-11-01
Ultrasonic driving of sessile semicylindrical bubbles results in powerful steady streaming flows that are robust over a wide range of driving frequencies. In a microchannel, this flow field pattern can be fine-tuned to achieve size-sensitive sorting and trapping of particles at scales much smaller than the bubble itself; the sorting mechanism has been successfully described based on simple geometrical considerations. We investigate the sorting process in more detail, both experimentally (using new parameter variations that allow greater control over the sorting) and theoretically (incorporating the device geometry as well as the superimposed channel flow into an asymptotic theory). This results in optimized criteria for size sorting and a theoretical description that closely matches the particle behavior close to the bubble, the crucial region for size sorting.
Contrôler la douleur et réduire l’usage abusif d’opioïdes
Kotalik, Jaro
2012-01-01
Résumé Objectif Aider les médecins de famille à faire un juste équilibre sur le plan de l’éthique dans leurs pratiques de prescription d’opioïdes. Source des données Une recension des articles en anglais publiés entre 1985 et 2011 a été effectuée dans MEDLINE. La majorité des données probantes étaient de niveau III. Message principal Il est essentiel de suivre les guides de pratique clinique quand on prescrit des opioïdes, sauf s’il est démontré qu’une autre option est justifiée. De plus, quand on réfléchit à la pertinence de prescrire des opioïdes et aux nombreuses implications sur le plan de l’éthique, il est utile de fonder sa décision sur l’application des principes éthiques de la bienfaisance, de la non-malfaisance, du respect de l’autonomie et de la justice. En outre, il est essentiel de se tenir au fait des changements dans les lois et la règlementation, ainsi qu’à propos des registres électroniques provinciaux des ordonnances d’opioïdes. Conclusion Les médecins doivent s’assurer que la douleur de leurs patients est bien évaluée et prise en charge. Le contrôle optimal de la douleur peut exiger la prescription d’opioïdes. Cependant, l’obligation de soulager la douleur doit être exercée en juste équilibre avec l’acquittement de la responsabilité tout aussi importante de ne pas exposer les patients au risque de dépendance et de ne pas créer de possibilités de détournement de drogues, de trafic et de dépendance chez d’autres personnes. Les principes éthiques fondamentaux offrent un cadre de réflexion qui peut aider les médecins à prendre des décisions appropriées sur le plan de l’éthique au sujet de la prescription d’opioïdes.
Approche à l’endroit des blessures traumatiques à la main en soins primaires
Cheung, Kevin; Hatchell, Alexandra; Thoma, Achilleas
2013-01-01
Résumé Objectif Passer en revue la prise en charge initiale des blessures traumatiques communes à la main que voient les médecins de soins primaires. Sources des données Nous avons examiné les données cliniques probantes et les ouvrages spécialisés récents cernés par des recherches dans la base de données électronique MEDLINE. Nous avons utilisé l’opinion d’experts pour compléter les recommandations dans les domaines où les données scientifiques étaient rares. Message principal Les médecins de soins primaires sont couramment appelés à prendre en charge des patients victimes de blessures traumatiques à la main. Dans le contexte d’un cas clinique, nous examinons l’évaluation, le diagnostic et la prise en charge initiale des traumatismes communs à la main. La présentation et la prise en charge des blessures au lit de l’ongle, des amputations de l’extrémité du doigt, des doigts en maillet, des fractures à la main, des lacérations de tendons, des morsures et de la ténosynovite infectieuse seront aussi discutées. Les principes de la prise en charge des blessures traumatiques à la main comportent la réduction et l’immobilisation des fractures, la prescription d’imagerie radiographique post-réduction, l’obtention d’un recouvrement par les tissus mous, la prévention et le traitement des infections et l’assurance d’une prophylaxie antitétanique. Conclusion Il est essentiel d’assurer une évaluation et une prise en charge appropriées des blessures traumatiques à la main pour prévenir une morbidité considérable à long terme dans une population autrement en santé. La reconnaissance sans délai des blessures qui nécessitent une demande de consultation urgente ou rapide auprès d’un chirurgien spécialiste de la main est également critique.
Falola, Stève Marjelin; Gouthon, Polycarpe; Falola, Jean-Marie; Fiogbe, Michel Armand; Nigan, Issiako Bio
2014-01-01
Introduction Le mobilier scolaire et la posture assise en classe sont souvent impliqués dans l'apparition des douleurs rachidiennes, influant de fait sur la qualité des tâches réalisées par les apprenants. Aucune étude n'a encore vérifié le degré d'adéquation entre les caractéristiques du mobilier et celles des écoliers au Bénin. L'objectif de cette étude transversale est donc de déterminer la relation entre les dimensions des table-bancs utilisées en classe et les mesures anthropométriques des écoliers au Bénin. Methods Elle a été réalisée avec un échantillon probabiliste de 678 écoliers, âgés de 4 à 17 ans. Les mesures anthropométriques des écoliers et les mensurations relatives aux longueurs, largeurs et hauteurs des table-bancs ont été mesurées, puis intégrées aux équations proposées dans la littérature. Les pourcentages des valeurs situées hors des limitesacceptables, dérivées de l'application des équations ont été calculés. Results La largeur et la hauteur des table-bancs utilisées par les écoliers étaient plus élevées (p < 0,05) que les valeurs de référence recommandées par les structures officielles de contrôle et de production des mobiliers scolaires au Bénin. Quel que soit le sexe, il y avait une inadéquation entre la largeur du banc et la longueur fesse-poplité, puis entre la hauteur de la table et la distance coude-bancdes écoliers. Conclusion Les résultats suggèrent de prendre en compte l’évolution des mesures anthropométriques des écoliers dans la confection des table-bancs, afin de promouvoir de bonnes postures assises en classe et de réduire le risque de troubles du rachis. PMID:25317232
Marshall, Shawn; Bayley, Mark; McCullagh, Scott; Velikonja, Diana; Berrigan, Lindsay
2012-01-01
Résumé Objectif Présenter les nouvelles lignes directrices sur la prise en charge des lésions cérébrales traumatiques légères (LCTL) et les symptômes persistants post-commotion (SPPC) afin de renseigner et d’orienter les médecins qui prennent en charge des patients qui se remettent d’une LCTL. Qualité des données On a effectué une recherche des guides de pratique clinique existants portant sur les LCTL et une synthèse critique des ouvrages scientifiques évaluant le traitement des SPPC. Étant donné la rareté des conseils sur la prise en charge des SPPC dans les travaux sur les lésions cérébrales traumatiques, une deuxième recherche documentaire a été faite pour recenser les guides de pratique clinique et les synthèses critiques concernant la prise en charge de ces symptômes communs dans la population en général. On a convoqué des professionnels de la santé provenant de différentes disciplines et régions du Canada et de l’étranger à une conférence consensuelle d’experts pour examiner les lignes directrices et les données probantes existantes et élaborer un guide complet pour la prise en charge des LCTL et des SPPC. Message principal À l’aide d’un processus Delphi modifié, on a produit 71 recommandations portant sur le diagnostic et la prise en charge des LCTL et des SPPC. De plus, on a inclus dans le guide de nombreuses ressources et des outils pour faciliter la mise en œuvre des recommandations. Conclusion Un guide de pratique clinique a été élaboré pour aider les professionnels de la santé à fournir des soins fondés sur les données probantes et les pratiques exemplaires à la population complexe de personnes qui ont des SPPC à la suite d’une LCTL.
La singularité du patient tuberculeux dans le système de santé: l'expérience du Burkina Faso
Zerbo, Roger
2013-01-01
La démarche pluridisciplinaire s'impose de plus en plus dans le secteur de la santé dans le contexte africain, où les parcours thérapeutiques sont pluriels et les rapports des usagers des centres de santé sont complexes et peu satisfaisants. La compréhension des représentations de la maladie est nécessaire pour offrir des soins appropriés certes, mais l'expérience individuelle des malades représente également une source de savoir. Les données ont été collectées à travers des entretiens semi-directifs, le recueil des récits de vie et des observations participantes. Cet article rend compte d'une expérience d'implication de socio-anthropologue dans la mise en œuvre d'un programme de santé publique au Burkina Faso en vue d'une amélioration de la prise en charge des malades tuberculeux. L'analyse des données à été conduite dans une visée réflexive. Les perspectives socio-anthropologiques ont révélé que l'expérience des anciens malades tuberculeux peut être mise à profit afin d'apporter des changements dans les relations thérapeutiques et l'intégration sociale des autres malades. Cette idée à été mise en application pour tenir lieu d'une traduction des analyses anthropologiques en actes pour un changement. L'article évoque la manière dont l'approche socio-anthropologique au sein d'un programme de santé, peut mettre en évidence le potentiel des malades à être des acteurs importants dans le fonctionnement des services de soins et leur propre bien-être. Dans cette situation, la démarche théorique implique la réflexivité de l'anthropologue, mais également un regard critique sur les modes d'intervention en santé publique. PMID:24009798
Bagny, Aklesso; Dusabe, Angelique; Bouglouga, Oumboma; Lawson-ananisoh, Mawuli Late; Kaaga, Yeba Laconi; Djibril, Mohaman Awalou; Soedje, Kokou Mensah; Dassa, Simliwa Kolou; Redah, Datouda
2014-01-01
Introduction L'hémorragie digestive haute est une urgence, qui constitue souvent pour les patients un danger mortel suscitant inquiétude et agitation. Dans cet état, le patient dépend de ses accompagnants pour ses soins et pour honorer le traitement; mais souvent, il a été observé une discordance entre l'urgence et les comportements des accompagnants. Le but de cette étude était de décrire les facteurs socioéconomiques et psychologiques pouvant influencer les comportements des accompagnants des patients admis pour HDH, estimer l'indice de relation entre ces comportements et les facteurs associés d'une part et le vécu des patients admis pour HDH d'autre part. Méthodes Il s'agit d'une étude prospective menée de Septembre 2010 à Juin 2011 (soit 10 mois). Nous avions utilisé l'entretien semi-dirigé et l'observation directe pour collecter nos données, ces dernières avaient été traitées par les méthodes statistiques et d'analyse de contenu. Résultats Dans la présente étude, les comportements des accompagnants des patients admis pour HDH sont en majorité marqués par l'abandon (84%) et le manque de sollicitude (80,2%). Ces comportements sont souvent stimulés par les facteurs socioéconomiques tels que les difficultés économiques (83,2%), des conflits intrafamiliaux (85,1%) et des représentations (maladie incurable ou envoûtement) de la maladie par les accompagnants (73,3%) des cas. Quant aux patients, ils vivent ces comportements comme étant des menaces de mort ou des rejets (77,20%) et comme étant une dévalorisation ou une humiliation de la part de leurs accompagnants (70,30%). Les résultats confirment l'existence de lien significatif entre les comportements des accompagnants et les facteurs socio économiques, entre les comportements des accompagnants et des facteurs psychologiques, et entre le vécu des patients admis pour l'HDH et les comportements des accompagnants. Conclusion Des études ultérieures devraient aborder les points non touchés dans cette étude. Certes, elle a apporté un plus dans la compréhension du vécu des patients admis pour HDH et des comportements de leurs accompagnants. Cependant, elle est loin d'avoir épuisé les différents contours de la problématique de la présente étude. PMID:25848453
NASA Astrophysics Data System (ADS)
Fareh, Fouad
Le moulage par injection basse pression des poudres metalliques est une technique de fabrication qui permet de fabriquer des pieces possedant la complexite des pieces coulees mais avec les proprietes mecaniques des pieces corroyees. Cependant, l'optimisation des etapes de deliantage et de frittage a ete jusqu'a maintenant effectuee a l'aide de melange pour lesquels la moulabilite optimale n'a pas encore ete demontree. Ainsi, la comprehension des proprietes rheologiques et de la segregation des melanges est tres limitee et cela presente le point faible du processus de LPIM. L'objectif de ce projet de recherche etait de caracteriser l'influence des liants sur le comportement rheologique des melanges en mesurant la viscosite et la segregation des melanges faible viscosite utilises dans le procede LPIM. Afin d'atteindre cet objectif, des essais rheologiques et thermogravimetriques ont ete conduits sur 12 melanges. Ces melanges ont ete prepares a base de poudre d'Inconel 718 de forme spherique (chargement solide constant a 60%) et de cires, d'agents surfactants ou epaississants. Les essais rheologiques ont ete utilises entre autre pour calculer l'indice d'injectabilite ?STV des melanges, tandis que les essais thermogravimetriques ont permis d'evaluer precisement la segregation des poudres dans les melanges. Il a ete demontre que les trois (3) melanges contenant de la cire de paraffine et de l'acide stearique presentent des indices alpha STV plus eleves qui sont avantageux pour le moulage par injection des poudres metalliques (MIM), mais segregent beaucoup trop pour que la piece fabriquee produise de bonnes caracteristiques mecaniques. A l'oppose, le melange contenant de la cire de paraffine et de l'ethylene-vinyle acetate ainsi que le melange contenant seulement de la cire de carnauba segregent peu voire pas du tout, mais possedent de tres faibles indices alphaSTV : ils sont donc difficilement injectables. Le meilleur compromis semble donc etre les melanges contenant de la cire (de paraffine, d'abeille et de carnauba) et de faible teneur en acide stearique et en ethylene-vinyle acetate. Par ailleurs, les lois physiques preexistantes ont permis de confirmer les resultats des essais rheologiques et thermogravimetriques, mais aussi de mettre en evidence l'influence de la segregation sur les proprietes rheologiques des melanges. Ces essais ont aussi montre l'effet de constituants de liant et du temps passe a l'etat fondu sur l'intensite de la segregation dans les melanges. Les melanges contenants de l'acide stearique segregent rapidement. La caracterisation des melanges developpes pour le moulage basse pression des poudres metalliques doit etre obtenue a l'aide d'une methode de courte duree pour eviter la segregation et de mesurer precisement l'aptitude a l'ecoulement de ces melanges.
Etude de l'amelioration de la qualite des anodes par la modification des proprietes du brai
NASA Astrophysics Data System (ADS)
Bureau, Julie
La qualite des anodes produites se doit d'etre bonne afin d'obtenir de l'aluminium primaire tout en reduisant le cout de production du metal, la consommation d'energie et les emissions environnementales. Or, l'obtention des proprietes finales de l'anode necessite une liaison satisfaisante entre le coke et le brai. Toutefois, la matiere premiere actuelle n'assure pas forcement la compatibilite entre le coke et le brai. Une des solutions les plus prometteuses, pour ameliorer la cohesion entre ces deux materiaux, est la modification des proprietes du brai. L'objectif de ce travail consiste a modifier les proprietes du brai par l'ajout d'additifs chimiques afin d'ameliorer la mouillabilite du coke par le brai modifie pour produire des anodes de meilleure qualite. La composition chimique du brai est modifiee en utilisant des tensioactifs ou agents de modification de surface choisis dans le but d'enrichir les groupements fonctionnels susceptibles d'ameliorer la mouillabilite. L'aspect economique, l'empreinte environnementale et l'impact sur la production sont consideres dans la selection des additifs chimiques. Afin de realiser ce travail, la methodologie consiste a d'abord caracteriser les brais non modifies, les additifs chimiques et les cokes par la spectroscopie infrarouge a transformee de Fourier (FTIR) afin d'identifier les groupements chimiques presents. Puis, les brais sont modifies en ajoutant un additif chimique afin de possiblement modifier ses proprietes. Differentes quantites d'additif sont ajoutees afin d'examiner l'effet de la variation de la concentration sur les proprietes du brai modifie. La methode FTIR permet d'evaluer la composition chimique des brais modifies afin de constater si l'augmentation de la concentration d'additif enrichit les groupements fonctionnels favorisant l'adhesion coke/brai. Ensuite, la mouillabilite du coke par le brai est observee par la methode goutte- sessile. Une amelioration de la mouillabilite par la modification a l'aide d'un additif chimique signifie une possible amelioration de l'interaction entre le coke et le brai modifie. Afin de completer l'evaluation des donnees recueillies, les resultats de la FTIR et de la mouillabilite sont analyses par le reseau neuronal artificiel afin de mieux comprendre les mecanismes sous-jacents. A la lumiere des resultats obtenus, les additifs chimiques les plus prometteurs sont selectionnes afin de verifier l'effet de leur utilisation sur la qualite des anodes. Pour ce faire, des anodes de laboratoire sont produites en utilisant des brais non modifies et des brais modifies avec les additifs chimiques selectionnes. Par la suite, les anodes sont carottees afin de les caracteriser en determinant certaines de leurs proprietes physiques et chimiques. Enfin, les resultats des echantillons d'anodes faites d'un meme brai non modifie et modifie sont compares afin d'evaluer l'amelioration de la qualite des anodes. Finalement, un examen de l'impact possible de l'utilisation d'un additif chimique pour modifier le brai sur la consommation energetique et en carbone ainsi que la quantite d'aluminium produit est realise. Afin de modifier le brai, trois differents additifs chimiques sont selectionnes, soit un tensioactif et deux agents de modification de surface. L'analyse FTIR des experimentations menees sur les brais modifies demontre que deux additifs ont modifie la composition chimique des brais experimentes. L'analyse des resultats des tests goutte-sessile laisse supposer qu'un brai modifie par ces deux additifs ameliore possiblement l'interaction avec les cokes employes dans cette etude. L'analyse par reseau neuronal artificiel des donnees recueillies permet de mieux comprendre le lien entre la composition chimique d'un brai et sa capacite de mouillabilite avec un coke. La caracterisation des echantillons d'anodes produites permet d'affirmer que ces deux additifs peuvent ameliorer certaines des proprietes anodiques comparativement aux echantillons standards. L'analyse des resultats demontre que l'un des deux additifs semble donner des resultats plus prometteurs. Au final, les travaux realises au cours de ce projet demontrent qu'il est possible d'ameliorer la qualite anodique en modifiant les proprietes du brai. De plus, l'analyse des resultats obtenus fournit une meilleure comprehension des mecanismes entre un brai et un additif chimique.
O'Brien, J K; Roth, T L; Stoops, M A; Ball, R L; Steinman, K J; Montano, G A; Love, C C; Robeck, T R
2015-01-01
White rhinoceros ejaculates (n=9) collected by electroejaculation from four males were shipped (10°C, 12h) to develop procedures for the production of chilled and frozen-thawed sex-sorted spermatozoa of adequate quality for artificial insemination (AI). Of all electroejaculate fractions, 39.7% (31/78) exhibited high quality post-collection (≥70% total motility and membrane integrity) and of those, 54.8% (17/31) presented reduced in vitro quality after transport and were retrospectively determined to exhibit urine-contamination (≥21.0μg creatinine/ml). Of fractions analyzed for creatinine concentration, 69% (44/64) were classified as urine-contaminated. For high quality non-contaminated fractions, in vitro parameters (motility, velocity, membrane, acrosome and DNA integrity) of chilled non-sorted and sorted spermatozoa were well-maintained at 5°C up to 54h post-collection, whereby >70% of post-transport (non-sorted) or post-sort (sorted) values were retained. By 54h post-collection, some motility parameters were higher (P<0.05) for non-sorted spermatozoa (total motility, rapid velocity, average path velocity) whereas all remaining motion parameters as well as membrane, acrosome and DNA integrity were similar between sperm types. In comparison with a straw method, directional freezing resulted in enhanced (P<0.05) motility and velocity of non-sorted and sorted spermatozoa, with comparable overall post-thaw quality between sperm types. High purity enrichment of X-bearing (89±6%) or Y-bearing (86±3%) spermatozoa was achieved using moderate sorting rates (2540±498X-spermatozoa/s; 1800±557Y-spermatozoa/s). Collective in vitro characteristics of sorted-chilled or sorted-frozen-thawed spermatozoa derived from high quality electroejaculates indicate acceptable fertility potential for use in AI. Copyright © 2014 Elsevier B.V. All rights reserved.
Encapsulation of sex sorted boar semen: sperm membrane status and oocyte penetration parameters.
Spinaci, Marcella; Chlapanidas, Theodora; Bucci, Diego; Vallorani, Claudia; Perteghella, Sara; Lucconi, Giulia; Communod, Ricardo; Vigo, Daniele; Galeati, Giovanna; Faustini, Massimo; Torre, Maria Luisa
2013-03-01
Although sorted semen is experimentally used for artificial, intrauterine, and intratubal insemination and in vitro fertilization, its commercial application in swine species is still far from a reality. This is because of the low sort rate and the large number of sperm required for routine artificial insemination in the pig, compared with other production animals, and the greater susceptibility of porcine spermatozoa to stress induced by the different sex sorting steps and the postsorting handling protocols. The encapsulation technology could overcome this limitation in vivo, protecting and allowing the slow release of low-dose sorted semen. The aim of this work was to evaluate the impact of the encapsulation process on viability, acrosome integrity, and on the in vitro fertilizing potential of sorted boar semen. Our results indicate that the encapsulation technique does not damage boar sorted semen; in fact, during a 72-hour storage, no differences were observed between liquid-stored sorted semen and encapsulated sorted semen in terms of plasma membrane (39.98 ± 14.38% vs. 44.32 ± 11.72%, respectively) and acrosome integrity (74.32 ± 12.17% vs. 66.07 ± 10.83%, respectively). Encapsulated sorted spermatozoa presented a lower penetration potential than nonencapsulated ones (47.02% vs. 24.57%, respectively, P < 0.0001), and a significant reduction of polyspermic fertilization (60.76% vs. 36.43%, respectively, polyspermic ova/total ova; P < 0.0001). However, no difference (P > 0.05) was observed in terms of total efficiency of fertilization expressed as normospermic oocytes/total oocytes (18.45% vs. 15.43% for sorted diluted and sorted encapsulated semen, respectively). The encapsulation could be an alternative method of storing of pig sex sorted spermatozoa and is potentially a promising technique in order to optimize the use of low dose of sexed spermatozoa in vivo. Copyright © 2013 Elsevier Inc. All rights reserved.
Li, Jibiao; Woolbright, Benjamin L; Zhao, Wen; Wang, Yifeng; Matye, David; Hagenbuch, Bruno; Jaeschke, Hartmut; Li, Tiangang
2018-01-01
Sortilin 1 (Sort1) is an intracellular trafficking receptor that mediates protein sorting in the endocytic or secretory pathways. Recent studies revealed a role of Sort1 in the regulation of cholesterol and bile acid (BA) metabolism. This study further investigated the role of Sort1 in modulating BA detoxification and cholestatic liver injury in bile duct ligated mice. We found that Sort1 knockout (KO) mice had attenuated liver injury 24 h after bile duct ligation (BDL), which was mainly attributed to less bile infarct formation. Sham-operated Sort1 KO mice had about 20% larger BA pool size than sham-operated wildtype (WT) mice, but 24 h after BDL Sort1 KO mice had significantly attenuated hepatic BA accumulation and smaller BA pool size. After 14 days BDL, Sort1 KO mice showed significantly lower hepatic BA concentration and reduced expression of inflammatory and fibrotic marker genes, but similar degree of liver fibrosis compared with WT mice. Unbiased quantitative proteomics revealed that Sort1 KO mice had increased hepatic BA sulfotransferase 2A1, but unaltered phase-I BA metabolizing cytochrome P450s or phase-III BA efflux transporters. Consistently, Sort1 KO mice showed elevated plasma sulfated taurocholate after BDL. Finally, we found that liver Sort1 was repressed after BDL, which may be due to BA activation of farnesoid x receptor. In conclusion, we report a role of Sort1 in the regulation of hepatic BA detoxification and cholestatic liver injury in mice. The mechanisms underlying increased hepatic BA elimination in Sort1 KO mice after BDL require further investigation. © The Author 2017. Published by Oxford University Press on behalf of the Society of Toxicology. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Reducing 4D CT artifacts using optimized sorting based on anatomic similarity.
Johnston, Eric; Diehn, Maximilian; Murphy, James D; Loo, Billy W; Maxim, Peter G
2011-05-01
Four-dimensional (4D) computed tomography (CT) has been widely used as a tool to characterize respiratory motion in radiotherapy. The two most commonly used 4D CT algorithms sort images by the associated respiratory phase or displacement into a predefined number of bins, and are prone to image artifacts at transitions between bed positions. The purpose of this work is to demonstrate a method of reducing motion artifacts in 4D CT by incorporating anatomic similarity into phase or displacement based sorting protocols. Ten patient datasets were retrospectively sorted using both the displacement and phase based sorting algorithms. Conventional sorting methods allow selection of only the nearest-neighbor image in time or displacement within each bin. In our method, for each bed position either the displacement or the phase defines the center of a bin range about which several candidate images are selected. The two dimensional correlation coefficients between slices bordering the interface between adjacent couch positions are then calculated for all candidate pairings. Two slices have a high correlation if they are anatomically similar. Candidates from each bin are then selected to maximize the slice correlation over the entire data set using the Dijkstra's shortest path algorithm. To assess the reduction of artifacts, two thoracic radiation oncologists independently compared the resorted 4D datasets pairwise with conventionally sorted datasets, blinded to the sorting method, to choose which had the least motion artifacts. Agreement between reviewers was evaluated using the weighted kappa score. Anatomically based image selection resulted in 4D CT datasets with significantly reduced motion artifacts with both displacement (P = 0.0063) and phase sorting (P = 0.00022). There was good agreement between the two reviewers, with complete agreement 34 times and complete disagreement 6 times. Optimized sorting using anatomic similarity significantly reduces 4D CT motion artifacts compared to conventional phase or displacement based sorting. This improved sorting algorithm is a straightforward extension of the two most common 4D CT sorting algorithms.
Les conseils des cliniciens canadiens en matière de commotion dans le sport sont-ils cohérents?
Carson, James D.; Rendely, Alexandra; Garel, Alisha; Meaney, Christopher; Stoller, Jacqueline; Kaicker, Jatin; Hayden, Leigh; Moineddin, Rahim; Frémont, Pierre
2016-01-01
Résumé Objectif Comparer les connaissances et l’utilisation des recommandations concernant la prise en charge de la commotion dans le sport (CDS) démontrées par les spécialistes de la médecine du sport et de l’exercice (SMSE) et les urgentologues afin d’évaluer la réussite du transfert des connaissances sur la CDS au Canada. Conception Un sondage à choix multiples envoyé par courriel et autoadministré par des SMSE et des urgentologues. La validité du contenu du sondage a fait l’objet d’une évaluation. Contexte Canada. Participants Le sondage a été complété entre mai et juillet 2012 par des SMSE qui ont réussi l’examen menant au diplôme de l’Académie canadienne de la médecine du sport et de l’exercice et des urgentologues qui n’avaient pas ce diplôme. Principaux paramètres à l’étude La connaissance et l’identification des sources d’information sur la prise en charge des commotions, l’utilisation des stratégies de diagnostic de la commotion et l’utilisation d’une terminologie courante et cohérente dans l’explication des stratégies de repos aux patients après une CDS. Résultats Le taux de réponse était de 28 % (305 sur 1085). Les taux de réponse par les SMSE et les urgentologues se situaient respectivement à 41 % (147 sur 360) et 22 % (158 sur 725). Parmi les répondants, 41 % des urgentologues et 3 % des SMSE n’étaient pas au courant de l’existence de déclarations consensuelles sur la commotion dans le sport; 74 % des SMSE utilisaient « habituellement ou toujours » la version 2 de l’Outil d’évaluation de la commotion dans le sport (SCAT2), tandis que 88 % des urgentologues n’utilisaient jamais le SCAT2. Aucune réponse uniforme n’a été documentée à la question visant à connaître les meilleurs modes de repos cognitif. Conclusion Nous avons cerné des différences et un manque d’uniformité chez les SMSE et les urgentologues dans la mise en application des recommandations concernant les patients ayant subi une CDS. Il semble que le SCAT2 soit davantage utilisé dans le milieu des SMSE que dans le contexte de l’urgence. Des efforts plus poussés de transfert des connaissances et en recherche devraient atténuer les obstacles à des conseils plus uniformes donnés par les médecins qui soignent des patients ayant subi une CDS.
Soins primaires aux adultes ayant une déficience développementale
Sullivan, William F.; Berg, Joseph M.; Bradley, Elspeth; Cheetham, Tom; Denton, Richard; Heng, John; Hennen, Brian; Joyce, David; Kelly, Maureen; Korossy, Marika; Lunsky, Yona; McMillan, Shirley
2011-01-01
Résumé Objectif Mettre à jour les lignes directrices canadiennes de 2006 sur les soins primaires aux adultes ayant une déficience développementale (DD) et présenter des recommandations pratiques fondées sur les connaissances actuelles pour traiter des problèmes de santé particuliers chez des adultes ayant une DD. Qualité des preuves Des professionnels de la santé expérimentés participant à un colloque et un groupe de travail subséquent ont discuté et convenu des révisions aux lignes directrices de 2006 en se fondant sur une recherche documentaire exhaustive, la rétroaction obtenue des utilisateurs du guide de pratique et les expériences cliniques personnelles. La plupart des preuves disponibles dans ce domaine viennent de l’opinion d’experts ou de déclarations consensuelles publiées (niveau III). Message principal Les adultes ayant une DD ont des problèmes de santé complexes, dont plusieurs diffèrent de ceux de la population en général. De bons soins primaires permettent d’identifier les problèmes de santé particuliers dont souffrent les adultes ayant une DD pour améliorer leur qualité de vie et leur accès aux soins de santé et prévenir la morbidité et le décès prématuré. Ces lignes directrices résument les problèmes de santé générale, physique, comportementale et mentale des adultes ayant une DD que devraient connaître les professionnels des soins primaires et présentent des recommandations pour le dépistage et la prise en charge en se basant sur les connaissances actuelles que les cliniciens peuvent mettre en pratique. En raison de l’interaction des facteurs biologiques, psychoaffectifs et sociaux qui contribuent à la santé et au bien-être des adultes ayant une DD, ces lignes directrices insistent sur la participation des aidants, l’adaptation des interventions, au besoin, et la consultation auprès de divers professionnels de la santé quand ils sont accessibles. Elles mettent aussi en évidence la nature éthique des soins. Les lignes directrices sont formulées dans le contexte d’un cadre éthique qui tient compte des questions comme le consentement éclairé et l’évaluation des bienfaits pour la santé par rapport aux risques de préjudice. Conclusion La mise en œuvre des lignes directrices proposées ici améliorerait la santé des adultes ayant une DD et minimiserait les disparités sur les plans de la santé et des soins de santé entre les adultes ayant une DD et la population en général.
Monolithic microfluidic concentrators and mixers
Frechet, Jean M.; Svec, Frantisek; Yu, Cong; Rohr, Thomas
2005-05-03
Microfluidic devices comprising porous monolithic polymer for concentration, extraction or mixing of fluids. A method for in situ preparation of monolithic polymers by in situ initiated polymerization of polymer precursors within microchannels of a microfluidic device and their use for solid phase extraction (SPE), preconcentration, concentration and mixing.
Limited by the lack of a sensitive, universal detector, many capillary-based liquid-phase separation techniques might benefit from techniques that overcome modest concentration sensitivity by preconcentrating large injection volumes. The work presented employs selective solid-ph...
Mechanisms of deterioration of nutrients. [improved quality of freeze-dried foods
NASA Technical Reports Server (NTRS)
Karel, M.; Flink, J. M.
1978-01-01
Methods for improving the quality of freeze-dried foods were investigated. Areas discussed include: (1) microstructure of freeze-dried systems, (2) structural changes in freeze-dried systems, (3) artificial food matrices, and (4) osmotic preconcentration to yield improved freeze-dried products.
A simple and rapid procedure for measuring total mercury in fish tissues is evaluated and
compared with conventional techniques. Using an automated instrument incorporating combustion, preconcentration by amalgamation with gold, and atomic absorption spectrometry (AAS), mill...
Taher, Mohammad Ali; Mazaheri, Lida; Ashkenani, Hamid; Mohadesi, Alireza; Afzali, Daryoush
2014-01-01
A new and sensitive SPE method using modified carbon nanotubes for extraction and preconcentration, and electrothermal atomic absorption spectrometric determination of nickel (Ni) in real samples at ng/L levels was investigated. First, multiwalled carbon nanotubes were oxidized with concentrated HNO3, then modified with 2-(5-bormo-2-pyridylazo)-5-diethylaminophenol reagent. The adsorption was achieved quantitatively on a modified carbon nanotubes column in a pH range of 6.5 to 8.5; the adsorbed Ni(II) ions were then desorbed by passing 5.0 mL of 1 M HNO3. The effects of analytical parameters, including pH of the solution, eluent type and volume, sample volume, flow rate of the eluent, and matrix ions, were investigated for optimization of the presented procedure. The enrichment factor was 180, and the LOD for Ni was 4.9 ng/L. The method was applied to the determination of Ni in water, food, and biological samples, and reproducible results were obtained.
Shamsipur, Mojtaba; Hashemi, Omid Reza; Safavi, Afsaneh
2005-09-01
A rapid flotation method for separation and enrichment of ultra trace amounts of copper(II), cadmium(II), nickel(II) and cobalt(II) ions from water samples is established. At pH 6.5 and with sodium dodecylsulfate used as a foaming reagent, Cu2+, Cd2+, Ni2+ and Co2+ were separated simultaneously with 2-aminocyclopentene-1-dithiocarboxylic acid (ACDA) added to 1 l of aqueous solution. The proposed procedure of preconcentration is applied prior to the determination of these four analytes using inductivity coupled plasma-atomic emission spectrometry (ICP-AES). The effects of pH, concentration of ACDA, applicability of different surfactants and foreign ions on the separation efficiency were investigated. The preconcentration factor of the method is 1000 and the detection limits of copper(II), cadmium(II), nickel(II) and cobalt(II) ions are 0.078, 0.075, 0.072 and 0.080 ng ml(-1), respectively.
The quality of our drinking water: aluminium determination with an acoustic wave sensor.
Veríssimo, Marta I S; Gomes, M Teresa S R
2008-06-09
A new methodology based on an inexpensive aluminium acoustic wave sensor is presented. Although the aluminium sensor has already been reported, and the composition of the selective membrane is known, the low detection limits required for the analysis of drinking water, demanded the inclusion of a preconcentration stage, as well as an optimization of the sensor. The necessary coating amount was established, as well as the best preconcentration protocol, in terms of oxidation of organic matter and aluminium elution from the Chelex-100. The methodology developed with the acoustic wave sensor allowed aluminium quantitation above 0.07 mg L(-1). Several water samples from Portugal were analysed using the acoustic wave sensor, as well as by UV-vis spectrophotometry. Results obtained with both methodologies were not statistically different (alpha=0.05), both in terms of accuracy and precision. This new methodology proved to be adequate for aluminium quantitation in drinking water and showed to be faster and less reagent consuming than the UV spectrophotometric methodology.
Avila, Mónica; Zougagh, Mohammed; Escarpa, Alberto; Ríos, Angel
2009-10-23
A new, simple and versatile method is presented for the determination of different concentration levels of alkenylbenzenes (eugenol, isoeugenol, eugenol methyl ether, myristicin, anethole and estragole) and the related flavour compounds (coumarin and pulegone) in food samples. The method involves the use of a stationary phase (capillary column) for the enrichment with appropriate elution. After the sample had completely passed through the capillary column the eluent was changed and the separation/detection was achieved. Excellent linearity was obtained under the proposed conditions for a direct determination method and a method including on-line preconcentration. The limits of detection were in the ranges 97-148 and 9.5-14.2 ng/mL, respectively. Evidence for a matrix effect was not found and recoveries between 92 and 110% were obtained. The precision of the method, expressed as relative standard deviation values, was below 5% in all cases. The applicability of this methodology was tested by analyzing synthetic and real food samples.
Stege, Patricia W; Sombra, Lorena L; Messina, Germán A; Martinez, Luis D; Silva, María F
2009-05-01
Many aromatic compounds can be found in the environment as a result of anthropogenic activities and some of them are highly toxic. The need to determine low concentrations of pollutants requires analytical methods with high sensitivity, selectivity, and resolution for application to soil, sediment, water, and other environmental samples. Complex sample preparation involving analyte isolation and enrichment is generally necessary before the final analysis. The present paper outlines a novel, simple, low-cost, and environmentally friendly method for the simultaneous determination of p-nitrophenol (PNP), p-aminophenol (PAP), and hydroquinone (HQ) by micellar electrokinetic capillary chromatography after preconcentration by cloud point extraction. Enrichment factors of 180 to 200 were achieved. The limits of detection of the analytes for the preconcentration of 50-ml sample volume were 0.10 microg L(-1) for PNP, 0.20 microg L(-1) for PAP, and 0.16 microg L(-1) for HQ. The optimized procedure was applied to the determination of phenolic pollutants in natural waters from San Luis, Argentina.
Huang, Zhuo; Ito, Kazuaki; Hirokawa, Takeshi
2004-11-05
A novel, simple and highly sensitive CE method was developed to determine total iodine (TI) in seawater. The method is based on the on-capillary reduction of iodine species to iodide by a reductant, introduced into the capillary before sample injection, the preconcentration of iodide using isotachophoresis, followed by its UV detection. Under optimized conditions for reduction and CE separation, the limit of detection for TI (S/N = 3) reached 0.4 microg L(-1) (226 nm). The repeatability of migration time and peak area, expressed by relative standard deviation, was 0.46 and 1.45%, respectively (n = 19). The correlation factor was 0.9991 (n = 10) for the concentration range of 12-115 microg I L(-1). The CE results obtained for the real seawater analysis agreed with the data of ion chromatography. To determine the genuine TI by the proposed method, organic iodinated compounds in the sample were treated with H202 and irradiation with UV light before analysis.
Raks, Victoria; Al-Suod, Hossam; Buszewski, Bogusław
2018-01-01
Development of efficient methods for isolation and separation of biologically active compounds remains an important challenge for researchers. Designing systems such as organomineral composite materials that allow extraction of a wide range of biologically active compounds, acting as broad-utility solid-phase extraction agents, remains an important and necessary task. Selective sorbents can be easily used for highly selective and reliable extraction of specific components present in complex matrices. Herein, state-of-the-art approaches for selective isolation, preconcentration, and separation of biologically active compounds from a range of matrices are discussed. Primary focus is given to novel extraction methods for some biologically active compounds including cyclic polyols, flavonoids, and oligosaccharides from plants. In addition, application of silica-, carbon-, and polymer-based solid-phase extraction adsorbents and membrane extraction for selective separation of these compounds is discussed. Potential separation process interactions are recommended; their understanding is of utmost importance for the creation of optimal conditions to extract biologically active compounds including those with estrogenic properties.
Daye, Mirna; Halwani, Jalal; Hamzeh, Mariam
2013-01-01
8-Hydroxyquinoline (8-HQ) was chosen as a powerful ligand for Hg solid phase extraction. Among several chelating resins based on 8-HQ, 5-phenylazo-8-hydroxyquinoline (5Ph8HQ) is used for mercury extraction in which the adsorption dynamics were fully studied. It has been shown that Hg(II) is totally absorbed by 5Ph8HQ within the first 30 minutes of contact time with t 1/2 5 minutes, following Langmuir adsorption model. At pH 4, the affinity of mercury is unchallenged by other metals except, for Cu(II), which have shown higher Kd value. With these latter characteristics, 5Ph8HQ was examined for the preconcentration of trace levels of Hg(II). The developed method showed quantitative recoveries of Hg(II) with LOD = 0.21 pg mL−1 and RSD = 3–6% using cold vapor atomic fluorescence spectroscopy (CV-AFS) with a preconcentration factor greater than 250. PMID:24459417
Akter, Fouzia; Saito, Shingo; Tasaki-Handa, Yuiko; Shibukawa, Masami
2018-01-01
A new analytical methodology for a simple and efficient on-line preconcentration of trace inorganic anions in water and salt samples prior to ion chromatographic determination is proposed. The preconcentration method is based on partition/ion-exclusion chromatographic ion stacking (PIEC ion stacking) with a hydrophilic polymer gel column containing a small amount of fixed anionic charges. The developed on-line PIEC ion stacking-ion chromatography method was validated by recovery experiments for the determination of nitrate in tap water in terms of both accuracy and precision, and the results showed the reliability of the method. The method proposed was also successfully applied to the determination of trace impurity nitrite and nitrate in reagent-grade salts of sodium sulfate. A low background level can be achieved since pure water is used as the eluant for the PIEC ion stacking. It is possible to reach sensitive detection at sub-μg L -1 levels by on-line PIEC ion stacking-ion chromatography.
Ozkantar, Nebiye; Yilmaz, Erkan; Soylak, Mustafa; Tuzen, Mustafa
2015-08-01
A solid-phase extraction method for separation and preconcentration of Ir(IV) ion by using activated carbon cloth (ACC) has been presented. Ir(IV) as their 1-(2-pyridylazo) 2-naphtol (PAN) chelate was adsorbed on ACC at pH 2.0 and was eluted from ACC with acidic dimethylformamide (DMF). The Ir(IV) concentration was determined at 536 nm as Ir(IV)-PAN complex by using UV-vis spectrophotometer. The analytical parameters including pH, sample and eluent flow rates, amount of PAN, eluent type, concentration, and sample volume were optimized. The effects of foreign ions on the recoveries of iridium were also investigated. The preconcentration factor was calculated as 60. The limit of detection (LOD) and the limit of quantification (LOQ) of the method were found as 0.039 and 0.129 μg L(-1), respectively. The method was applied to soil and water samples for iridium determination.
Ning, Yu; Li, Jihui; Cai, Wensheng; Shao, Xueguang
2012-10-01
A method for simultaneous determination of metal ions in river water was developed by using preconcentration and near-infrared diffuse reflectance spectroscopy (NIRDRS). An inorganic biomaterial, nano-hydroxyapatite (HAP) was used as a high-efficient adsorbent for gathering the ions from water samples. After adsorbing the analytes onto the adsorbent, NIRDRS was measured and partial least squares (PLS) models were established for fast and simultaneous quantitative prediction. With the samples prepared by river water, determination of Pb(2+), Zn(2+), Cu(2+), Cd(2+) and Cr(3+) was investigated. The calibration models of Cu(2+), Cr(3+) and total content were proven to be efficient enough for precise prediction. The determination coefficients (R(2)) of the independent validation were found as high as 0.9924, 0.9869 and 0.9273 for Cu(2+), Cr(3+) and total content, respectively. Therefore, the feasibility of NIRDRS for microanalysis of heavy metal ions in waste water was demonstrated. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Wu, X. Z.; Liu, Y.; Luo, L. L.; Chen, Z. Y.
2018-01-01
Adsorbents PAMAM-n.0MBTSG (n=1-4) have been prepared by immobilizing polyamidoamine (PAMAM) and 2-mercaptobenzothiazole (MBT) on silica-gel. Characterized with FTIR, SEM, TGA, the preconcentration of Pb2+ with PAMAM-n.0MBTSG(n=1-4) has been investigated by graphite furnace atomic absorption spectroscopy (GFAAS). SEM showed that the surface morphology of adsorbent changed with the generation increase of PAMAM. Adsorption capacity of PAMAM-n.0MBTSG for Pb2+ (n=1-4) reached 16.22, 19.84, 22.92 and 27.56 mg g-1 respectively. Pb2+ (1.0 ng mL-1) in 2000 mL solution could be quantitatively absorbed with PAMAM-4.0MBTSG and eluted to obtain a preconcentration factor (PF) of 200. GFAAS method for analysis of Pb2+ with PAMAM-4.0MBTSG as adsorbent was proposed and successfully applied to analysis of Pb2+ of standard reference material, sea water and squid sample.
Rahimi Moghadam, Mojtaba; Zargar, Behrooz; Rastegarzadeh, Saadat
2018-04-30
Herein, magnetically hollow zein nanoparticles were synthesized and used as a magnetic sorbent for the preconcentration of chlorpyrifos and its analysis by high-performance liquid chromatography (HPLC). Morphology of the sorbent was characterized by transmission electron microscopy (TEM). In this study, the effects of important parameters such as pH of the solution, adsorption and desorption time, type and volume of desorption solvent, and salt addition were investigated. Under optimized experimental conditions, the linear range was from 50 to 2000 μg mL-1, and an LOD of 25 μg L-1 was calculated. The relative standard deviations (RSD) varied from 3.8 to 5.1% (n = 5). The enrichment factors for 50 and 100 μg L-1 samples were calculated as 187 and 210, respectively. The developed method was successfully applied in soil and water samples and showed good extraction recoveries.
NASA Astrophysics Data System (ADS)
Maddah, B.; Hosseini, F.; Ahmadi, M.; Rajabi, A. Asghar; Beik-Mohammadlood, Z.
2016-05-01
A novel and sensitive extraction procedure using sodium dodecyl sulfate (SDS) modified maghemite nanoparticles (MNPs) as an efficient solid phase has been developed for removal, preconcentration, and spectrophotometric determination of trace amounts of a naphthalene analog of dexmedetomidine (4-(1-(na phthalene-1-yl)ethyl)-1Himidazole, NMED). The MNPs were obtained by a coprecipitation method, and their surfaces were furthermore modified by SDS. The size and morphological properties of the synthesized MNPs were determined by X-ray diffraction analysis, FT-IR, vibrating sample magnetometry, and scanning electron microscopy. NMED was adsorbed at pH 3.0. The adsorbed drug was then desorbed and determined by spectrophotometry at 280 nm. The calibration graph was linear in the range 1 × 10-6-1 × 10-4 mol/L of NMED with a correlation coefficient of 0.989. The detection limit of the method for NMED determination was 3.7 × 10-7 mol/L. The method was successfully applied to the determination of NMED in human urine samples.
Corazza, Marcela Zanetti; Pires, Igor Matheus Ruiz; Diniz, Kristiany Moreira; Segatelli, Mariana Gava; Tarley, César Ricardo Teixeira
2015-08-01
A facile and reliable UV-Vis spectrophotometric method associated with vortex-assisted dispersive liquid-liquid microextraction has been developed and applied to the determination of U(VI) at low levels in water samples. It was based on preconcentration of 24.0 mL sample at pH 8.0 in the presence of 7.4 µmol L(-1) 1-(2-pyridylazo)-2-naphthol, 1.0 mL of methanol as disperser solvent and 1.0 mL of chloroform as extraction solvent. A high preconcentration factor was achieved (396 times), thus providing a wide analytical curve from 6.9 up to 75.9 µg L(-1) (r=0.9982) and limits of detection and quantification of 0.40 and 1.30 µg L(-1), respectively. When necessary, EDTA or KCN can be used to remove interferences of foreign ions. The method was applied to the analysis of real water samples, such as tap, mineral and lake waters with good recovery values.
Wang, Zonghua; Han, Qiang; Xia, Jianfei; Xia, Linhua; Ding, Mingyu; Tang, Jie
2013-06-01
Graphene has great potentials for the use in sample preparation due to its ultra high specific surface area, superior chemical stability, and excellent thermal stability. In our work, a novel graphene-based SPE disk was developed for separation and preconcentration of trace polycyclic aromatic hydrocarbons from environmental water samples. Based on the strong π-π stacking interaction between the analytes and graphene, the analytes extracted by graphene were eluted by cyclohexane and then determined by GC-MS. Under the optimized conditions, high flow rate (30 mL/min) and sensitivity (0.84-13 ng/L) were achieved. The proposed method was successfully applied to the analysis of real environmental water samples with recoveries ranging from 72.8 to 106.2%. Furthermore, the property of anticlogging and reusability was also improved. This work reveals great potentials of graphene-based SPE disk in environmental analytical. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Thorstensen, C W; Christiansen, A
2001-09-01
A method for the extraction of bentazone, dichlorprop, and MCPA in three selected Norwegian soils of different textures is described. Initially three different extraction methods were tested on one soil type. All methods gave recoveries >80% for the pesticide mixture, but extraction with sodium hydroxide in combination with solid-phase preconcentration was used for further recovery tests with soils of different properties spiked at four herbicide concentration levels (0.001-10 microg/g of wet soil). The method was rapid and easy and required a minimum of organic solvents. The recoveries were in the range of 82-109, 80-123, and 45-91% for the soils containing 1.4 (Hole), 2.5 (Kroer), and 37.8% (Froland) organic carbon, respectively. Limits of quantification using GC-MS were 0.0003 microg/g of wet soil for bentazone and 0.0001 microg/g of wet soil for both dichlorprop and MCPA.
Dziomba, Szymon; Araya-Farias, Monica; Smadja, Claire; Taverna, Myriam; Carbonnier, Benjamin; Tran, N Thuy
2017-02-22
Determination of proteins and peptides is among the main challenges of today's bioanalytical chemistry. The application of microchip technology in this field is an exhaustively developed concept that aims to create integrated and fully automated analytical devices able to quantify or detect one or several proteins from a complex matrix. Selective extraction and preconcentration of targeted proteins and peptides especially from biological fluids is of the highest importance for a successful realization of these microsystems. Incorporation of solid structures or supports is a convenient solution employed to face these demands. This review presents a critical view on the latest achievements in sample processing techniques for protein determination using solid supports in microfluidics. The study covers the period from 2006 to 2015 and focuses mainly on the strategies based on microbeads, monolithic materials and membranes. Less common approaches are also briefly discussed. The reviewed literature suggests future trends which are discussed in the concluding remarks. Copyright © 2016 Elsevier B.V. All rights reserved.
NIH Toolbox Cognition Battery (NIHTB-CB): list sorting test to measure working memory.
Tulsky, David S; Carlozzi, Noelle; Chiaravalloti, Nancy D; Beaumont, Jennifer L; Kisala, Pamela A; Mungas, Dan; Conway, Kevin; Gershon, Richard
2014-07-01
The List Sorting Working Memory Test was designed to assess working memory (WM) as part of the NIH Toolbox Cognition Battery. List Sorting is a sequencing task requiring children and adults to sort and sequence stimuli that are presented visually and auditorily. Validation data are presented for 268 participants ages 20 to 85 years. A subset of participants (N=89) was retested 7 to 21 days later. As expected, the List Sorting Test had moderately high correlations with other measures of working memory and executive functioning (convergent validity) but a low correlation with a test of receptive vocabulary (discriminant validity). Furthermore, List Sorting demonstrates expected changes over the age span and has excellent test-retest reliability. Collectively, these results provide initial support for the construct validity of the List Sorting Working Memory Measure as a measure of working memory. However, the relationship between the List Sorting Test and general executive function has yet to be determined.
Manual sorting to eliminate aflatoxin from peanuts.
Galvez, F C F; Francisco, M L D L; Villarino, B J; Lustre, A O; Resurreccion, A V A
2003-10-01
A manual sorting procedure was developed to eliminate aflatoxin contamination from peanuts. The efficiency of the sorting process in eliminating aflatoxin-contaminated kernels from lots of raw peanuts was verified. The blanching of 20 kg of peanuts at 140 degrees C for 25 min in preheated roasters facilitated the manual sorting of aflatoxin-contaminated kernels after deskinning. The manual sorting of raw materials with initially high aflatoxin contents (300 ppb) resulted in aflatoxin-free peanuts (i.e., peanuts in which no aflatoxin was detected). Verification procedures showed that the sorted sound peanuts contained no aflatoxin or contained low levels (<15 ppb) of aflatoxin. The results obtained confirmed that the sorting process was effective in separating contaminated peanuts whether or nor contamination was extensive. At the commercial level, when roasters were not preheated, the dry blanching of 50 kg of peanuts for 45 to 55 min facilitated the proper deskinning and subsequent manual sorting of aflatoxin-contaminated peanut kernels from sound kernels.
Automated spike sorting algorithm based on Laplacian eigenmaps and k-means clustering.
Chah, E; Hok, V; Della-Chiesa, A; Miller, J J H; O'Mara, S M; Reilly, R B
2011-02-01
This study presents a new automatic spike sorting method based on feature extraction by Laplacian eigenmaps combined with k-means clustering. The performance of the proposed method was compared against previously reported algorithms such as principal component analysis (PCA) and amplitude-based feature extraction. Two types of classifier (namely k-means and classification expectation-maximization) were incorporated within the spike sorting algorithms, in order to find a suitable classifier for the feature sets. Simulated data sets and in-vivo tetrode multichannel recordings were employed to assess the performance of the spike sorting algorithms. The results show that the proposed algorithm yields significantly improved performance with mean sorting accuracy of 73% and sorting error of 10% compared to PCA which combined with k-means had a sorting accuracy of 58% and sorting error of 10%.A correction was made to this article on 22 February 2011. The spacing of the title was amended on the abstract page. No changes were made to the article PDF and the print version was unaffected.
A Simple Deep Learning Method for Neuronal Spike Sorting
NASA Astrophysics Data System (ADS)
Yang, Kai; Wu, Haifeng; Zeng, Yu
2017-10-01
Spike sorting is one of key technique to understand brain activity. With the development of modern electrophysiology technology, some recent multi-electrode technologies have been able to record the activity of thousands of neuronal spikes simultaneously. The spike sorting in this case will increase the computational complexity of conventional sorting algorithms. In this paper, we will focus spike sorting on how to reduce the complexity, and introduce a deep learning algorithm, principal component analysis network (PCANet) to spike sorting. The introduced method starts from a conventional model and establish a Toeplitz matrix. Through the column vectors in the matrix, we trains a PCANet, where some eigenvalue vectors of spikes could be extracted. Finally, support vector machine (SVM) is used to sort spikes. In experiments, we choose two groups of simulated data from public databases availably and compare this introduced method with conventional methods. The results indicate that the introduced method indeed has lower complexity with the same sorting errors as the conventional methods.
NIH Toolbox Cognition Battery (NIHTB-CB): The List Sorting Test to Measure Working Memory
Tulsky, David S.; Carlozzi, Noelle; Chiaravalloti, Nancy D.; Beaumont, Jennifer L.; Kisala, Pamela A.; Mungas, Dan; Conway, Kevin; Gershon, Richard
2015-01-01
The List Sorting Working Memory Test was designed to assess working memory (WM) as part of the NIH Toolbox Cognition Battery. List Sorting is a sequencing task requiring children and adults to sort and sequence stimuli that are presented visually and auditorily. Validation data are presented for 268 participants ages 20 to 85 years. A subset of participants (N=89) was retested 7 to 21 days later. As expected, the List Sorting Test had moderately high correlations with other measures of working memory and executive functioning (convergent validity) but a low correlation with a test of receptive vocabulary (discriminant validity). Furthermore, List Sorting demonstrates expected changes over the age span and has excellent test-retest reliability. Collectively, these results provide initial support the construct validity of the List Sorting Working Memory Measure as a measure of working memory. However, the relation between the List Sorting Test and general executive function has yet to be determined. PMID:24959983
Mahawong, Phitsanu; Sinclair, Adriane; Li, Yi; Schlomer, Bruce; Rodriguez, Esequiel; Max, Ferretti M.; Liu, Baomei; Baskin, Laurence S.; Cunha, Gerald R.
2014-01-01
Potential trans-generational influence of diethylstilbestrol (DES) exposure emerged with reports of effects in grandchildren of DES-treated pregnant women and of reproductive tract tumors in offspring of mice exposed in utero to DES. Accordingly, we examined the trans-generational influence of DES on development of external genitalia (ExG) and compared effects of in utero DES exposure in CD-1 and C57BL/6 mice injected with oil or DES every other day from gestational days 12 to 18. Mice were examined at birth, and on 5 to 120 days postnatal to evaluate ExG malformations. Of 23 adult (≥60 days) prenatally DES-exposed males, features indicative of urethral meatal hypospadias (see text for definitions) ranged from 18 to 100% in prenatally DES-exposed CD-1 males and 31 to 100% in prenatally DES-exposed C57BL/6 males. Thus, the strains differed in the incidence of male urethral hypospadias. Ninety-one percent of DES-exposed CD-1 females and 100% of DES-exposed C57BL/6 females had urethral-vaginal fistula. All DES-exposed CD-1 and C57BL/6 females lacked an os clitoris. None of the prenatally oil-treated CD-1 and C57BL/6 male and female mice had ExG malformations. For the second-generation study, 10 adult CD-1 males and females, from oil- and DES-exposed groups, respectively, were paired with untreated CD-1 mice for 30 days, and their offspring evaluated for ExG malformations. None of the F1 DES-treated females were fertile. Nine of 10 prenatally DES-exposed CD-1 males sired offspring with untreated females, producing 55 male and 42 female pups. Of the F2 DES-lineage adult males, 20% had exposed urethral flaps, a criterion of urethral meatal hypospadias. Five of 42 (11.9%) F2 DES lineage females had urethral-vaginal fistula. In contrast, all F2 oil-lineage males and all oil-lineage females were normal. Thus, prenatal DES exposure induces malformations of ExG in both sexes and strains of mice, and certain malformations are transmitted to the second-generation. PMID:25449352
Methodes iteratives paralleles: Applications en neutronique et en mecanique des fluides
NASA Astrophysics Data System (ADS)
Qaddouri, Abdessamad
Dans cette these, le calcul parallele est applique successivement a la neutronique et a la mecanique des fluides. Dans chacune de ces deux applications, des methodes iteratives sont utilisees pour resoudre le systeme d'equations algebriques resultant de la discretisation des equations du probleme physique. Dans le probleme de neutronique, le calcul des matrices des probabilites de collision (PC) ainsi qu'un schema iteratif multigroupe utilisant une methode inverse de puissance sont parallelises. Dans le probleme de mecanique des fluides, un code d'elements finis utilisant un algorithme iteratif du type GMRES preconditionne est parallelise. Cette these est presentee sous forme de six articles suivis d'une conclusion. Les cinq premiers articles traitent des applications en neutronique, articles qui representent l'evolution de notre travail dans ce domaine. Cette evolution passe par un calcul parallele des matrices des PC et un algorithme multigroupe parallele teste sur un probleme unidimensionnel (article 1), puis par deux algorithmes paralleles l'un mutiregion l'autre multigroupe, testes sur des problemes bidimensionnels (articles 2--3). Ces deux premieres etapes sont suivies par l'application de deux techniques d'acceleration, le rebalancement neutronique et la minimisation du residu aux deux algorithmes paralleles (article 4). Finalement, on a mis en oeuvre l'algorithme multigroupe et le calcul parallele des matrices des PC sur un code de production DRAGON ou les tests sont plus realistes et peuvent etre tridimensionnels (article 5). Le sixieme article (article 6), consacre a l'application a la mecanique des fluides, traite la parallelisation d'un code d'elements finis FES ou le partitionneur de graphe METIS et la librairie PSPARSLIB sont utilises.
NASA Astrophysics Data System (ADS)
El Mansouri, Souleimane
Dans le domaine viscoelastique lineaire (VEL, domaine des petites deformations), le comportement thermomecanique du bitume et du mastic bitumineux (melange uniforme de bitume et de fillers) a ete caracterise au Laboratoire des Chaussees et Materiaux Bitumineux (LCMB) de l'Ecole de technologie superieure (ETS) avec l'appui de nos partenaires externes : la Societe des Alcools du Quebec (SAQ) et Eco Entreprises Quebec (EEQ). Les proprietes rheologiques des bitumes et des mastics ont ete mesurees grâce a un nouvel outil d'investigation appele, Rheometre a Cisaillement Annulaire (RCA), sous differentes conditions de chargement. Cet appareil permet non seulement de solliciter des eprouvettes de tailles importantes par rapport a celles utilisees lors des essais classiques, mais aussi d'effectuer des essais en conditions quasi-homogenes, ce qui permet de donner acces a la loi de comportement des materiaux. Les essais sont realises sur une large gamme de temperatures et de frequences (de -15 °C a 45°C et de 0,03Hz a 10 Hz). Cette etude a ete menee principalement pour comparer le comportement d'un bitume avec celui d'un mastic bitumineux dans le domaine des petites deformations. neanmoins, dans une seconde perspective, on s'interesse a l'influence des fillers de verre de post-consommation sur le comportement d'un mastic a faibles niveaux de deformations en comparant l'evolution des modules complexes de cisaillements (G*) d'un mastic avec fillers de verre et un mastic avec fillers conventionnels (calcaire). Enfin, le modele analogique 2S2P1D est utilise pour simuler le comportement viscoelastique lineaire des bitumes et des mastics bitumineux testes lors de la campagne experimentale.
Membrane fluidization by alcohols inhibits DesK-DesR signalling in Bacillus subtilis.
Vaňousová, Kateřina; Beranová, Jana; Fišer, Radovan; Jemioła-Rzemińska, Malgorzata; Matyska Lišková, Petra; Cybulski, Larisa; Strzałka, Kazimierz; Konopásek, Ivo
2018-03-01
After cold shock, the Bacillus subtilis desaturase Des introduces double bonds into the fatty acids of existing membrane phospholipids. The synthesis of Des is regulated exclusively by the two-component system DesK/DesR; DesK serves as a sensor of the state of the membrane and triggers Des synthesis after a decrease in membrane fluidity. The aim of our work is to investigate the biophysical changes in the membrane that are able to affect the DesK signalling state. Using linear alcohols (ethanol, propanol, butanol, hexanol, octanol) and benzyl alcohol, we were able to suppress Des synthesis after a temperature downshift. The changes in the biophysical properties of the membrane caused by alcohol addition were followed using membrane fluorescent probes and differential scanning calorimetry. We found that the membrane fluidization induced by alcohols was reflected in an increased hydration at the lipid-water interface. This is associated with a decrease in DesK activity. The addition of alcohol mimics a temperature increase, which can be measured isothermically by fluorescence anisotropy. The effect of alcohols on the membrane periphery is in line with the concept of the mechanism by which two hydrophilic motifs located at opposite ends of the transmembrane region of DesK, which work as a molecular caliper, sense temperature-dependent variations in membrane properties. Copyright © 2017 Elsevier B.V. All rights reserved.
Regulation of synaptic activity by snapin-mediated endolysosomal transport and sorting
Di Giovanni, Jerome; Sheng, Zu-Hang
2015-01-01
Recycling synaptic vesicles (SVs) transit through early endosomal sorting stations, which raises a fundamental question: are SVs sorted toward endolysosomal pathways? Here, we used snapin mutants as tools to assess how endolysosomal sorting and trafficking impact presynaptic activity in wild-type and snapin−/− neurons. Snapin acts as a dynein adaptor that mediates the retrograde transport of late endosomes (LEs) and interacts with dysbindin, a subunit of the endosomal sorting complex BLOC-1. Expressing dynein-binding defective snapin mutants induced SV accumulation at presynaptic terminals, mimicking the snapin−/− phenotype. Conversely, over-expressing snapin reduced SV pool size by enhancing SV trafficking to the endolysosomal pathway. Using a SV-targeted Ca2+ sensor, we demonstrate that snapin–dysbindin interaction regulates SV positional priming through BLOC-1/AP-3-dependent sorting. Our study reveals a bipartite regulation of presynaptic activity by endolysosomal trafficking and sorting: LE transport regulates SV pool size, and BLOC-1/AP-3-dependent sorting fine-tunes the Ca2+ sensitivity of SV release. Therefore, our study provides new mechanistic insights into the maintenance and regulation of SV pool size and synchronized SV fusion through snapin-mediated LE trafficking and endosomal sorting. PMID:26108535
Le patrimoine astronomique provençal
NASA Astrophysics Data System (ADS)
Rous, M.; Figon, P.; Guyot, S.
2012-12-01
L'OSU OAMP/Institut Pythéas porte les missions de conservation, inventaire et valorisation du patrimoine. Suite à la fusion de l'Observatoire de Marseille et du Laboratoire d'Astronomie Spatiale en 2000 pour créer le Laboratoire d'Astrophysique de Marseille, le déménagement des équipes sur le site de Château-Gombert en 2008 a soulevé le problème du devenir des collections des deux sites d'origine. Nous ferons le bilan des actions passées en matière de conservation et de valorisation de ce riche patrimoine : versement à l'inventaire général du Ministère de la Culture, classement de 22 instruments au titre des Monuments Historiques, inventaire et numérisation des archives anciennes, montage d'expositions et réalisation du catalogue Telescopium, 400 ans de lunettes et de télescopes. Nous présenterons les actions en cours: mesures de conservation préventive, inventaire des archives et des instruments. Nous parlerons enfin des projets: création d'un espace d'exposition permanente, participation à des expositions temporaires.
NASA Astrophysics Data System (ADS)
Schober, Helmut; Fischer, Henry; Leclercq-Hugeux, Françoise
2003-09-01
L'École Thématique “Structure et Dynamique des Systèmes Désordonnés” [1] s'inscrit dans le cadre des écoles organisées sous l'impulsion de la Société Française de la Neutronique (SFN). Elle s'est deroulée en mai 2002 sur la Presqu'île de Giens (Var) en première partie des 11émes Journées de la Diffusion Neutronique. L'Édition de ces cours constitue ainsi le cinquième ouvrage introduisant les techniques neutroniques et leurs apports à differentes thématiques [2]. Le désordre est un facteur déterminant pour pratiquement toutes les propriétés des matériaux. Il est inhérent dans les matériaux amorphes ou liquides, mais il détermine également les propriétés mécaniques et électroniques d'autres composés d'importance technologique comme les matériaux métalliques, dont l'aspect “désordonné” est moins évident. Le désordre enfin joue un rôle essentiel dans tout ce que touche à la vie. En fait, il est difficile d'imaginer des systèmes, à part quelques exceptions rares comme l'hélium ou le silicium de haute pureté, où il n'y ait pas de désordre. En dehors de cet aspect pratique, la description scientifique du désordre atomique pose toujours des problèmes fondamentaux faute de concepts pertinents. Une des tâches importantes du scientifique ou de l'ingenieur est de préciser quel genre de désordre existe à une échelle d'espace et de temps donnée. Un materiau peut très bien être homogène à l'échelle atomique et présenter des défauts ou des hétrogéneité visibles à l'œil et inversement. De même, un système désordonné à un instant donné, peut apparaître ordonné si on moyenne dans le temps. Les techniques de diffusion des neutrons sont idéales pour aborder ces questions. Les neutrons sondent directement les noyaux et ont à la fois des longueurs d'ondes proches des distances inter atomiques et des énergies avoisinant celles des excitations élémentaires de la matière condensée. Ils permettent ainsi une observation directe et non-destructive des positions et des mouvements atomiques. La gamme des distances et des temps sondés par les neutrons autorisent aussi bien de suivre le mouvement des atomes à l'échelle inter atomique que l'évolution d'une structure soit mésoscopique soit macroscopique sur des temps de moins d'une picoseconde à plusieurs heures. La gamme des techniques de diffusion utilisées pour couvrir un tel champ d'application est naturellement très large : différents types de diffractomètres permettent des études de structure atomique trés pointue et résolue dans le temps. Les spectromètres nous donnent accès à la dynamique d'une dizaine de femto- à plusieurs nanosecondes. La diffusion aux petits angles, la reflectomètrie et finalement la tomographie nous permettent de regarder la structure et la dynamique d'objets plus grands. Il était illusoire de prétendre couvrir la totalité des systèmes désordonnés et l'ensemble des techniques de diffusion neutronique pertinentes au cours d'une école de 3 jours. Nous avons donc été amené à nous concentrer sur les liquides, les verres, les cristaux plastiques et les polymères. Ce choix s'est imposé par le souhait d'introduire les concepts de base, en acceptant de sacrifier certains domaines d'applications. Il va de soi que l'étude approfondie de systèmes mettant en jeu plusieurs échelles de distance (structure moléculaire, portée des corrélations entre les molécules) et de temps (relaxations caractéristiques des divers phenomènes dynamiques selon leur extension spatiale) implique une pluralité de techniques expérimentales, complémentaires des différentes techniques neutroniques disponibles. Un des objectifs de cette école etait donc de préciser les domaines de pertinence des différentes techniques neutroniques disponibles en en situant la complémentarité avec d'autres approches instrumentales (diffraction des rayons X, EXAFS, RMN, etc.). Enfin la confrontation avec les résultats obtenus par simulation et modélisation numérique est essentielle à la compréhension des processus élémentaires dans ces systèmes complexes. En première partie de cet ouvrage, on trouvera une description géntrale des systèmes désordonnés et une introduction aux techniques de diffusion de neutrons. Pour la partie concernant la structure, une revue des techniques de diffraction est suivie par des applications à des systèmes de complexité croissante (liquides métalliques simples, alliages liquides, semiconducteurs fondus, solutions aqueuses, verres d'oxydes). L'apport des méthodes de variation de longueur de diffusion (substitution isotopique pour les mesures aux neutrons, diffusion anomale des rayons X ou combinaison de ces deux techniques) permet la détermination des facteurs de structures partiels. Pour la dynamique, on a privilégié une approche introduisant progressivement le désordre en passant des solides aux liquides. Le concept de diffusion puis les particularités dynamiques des verres sont ensuite présentés et illustrés par des exemples concrets. Enfin la dernière partie est consacrée à la simulation numérique des propriétés dynamiques des verres et des liquides et à la modélisation de la structure par méthode de Monte Carlo inverse (RMC) à partir de l'ensemble des données expérimentales existant pour un système donné. La communauté française a joué un rôle important dans le développement des techniques neutroniques dédites à l'étude des systèmes désordonnés et y a acquis une competence reconnue. Nous avons essayé, dans cet ouvrage, de privilégier les aspects pédagogiques des cours, pour les rendre accessibles aux scientifiques francophones non spécialistes en diffusion des neutrons. Nous saluons ici l'effort de rédaction, en langue française, des différents intervenants et souhaitons que cet ouvrage puisse participer à la formation et au renouvellement de la communauté neutronique française. Helmut Schober et Henry Fischer (Editeurs scientifiques) Françoise Leclercq-Hugeux (Présidente de la SFN)
Yu, Jessica S; Pertusi, Dante A; Adeniran, Adebola V; Tyo, Keith E J
2017-03-15
High throughput screening by fluorescence activated cell sorting (FACS) is a common task in protein engineering and directed evolution. It can also be a rate-limiting step if high false positive or negative rates necessitate multiple rounds of enrichment. Current FACS software requires the user to define sorting gates by intuition and is practically limited to two dimensions. In cases when multiple rounds of enrichment are required, the software cannot forecast the enrichment effort required. We have developed CellSort, a support vector machine (SVM) algorithm that identifies optimal sorting gates based on machine learning using positive and negative control populations. CellSort can take advantage of more than two dimensions to enhance the ability to distinguish between populations. We also present a Bayesian approach to predict the number of sorting rounds required to enrich a population from a given library size. This Bayesian approach allowed us to determine strategies for biasing the sorting gates in order to reduce the required number of enrichment rounds. This algorithm should be generally useful for improve sorting outcomes and reducing effort when using FACS. Source code available at http://tyolab.northwestern.edu/tools/ . k-tyo@northwestern.edu. Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com
Likwela, Joris Losimba; Otokoye, John Otshudiema
2015-01-01
Les formes graves de paludisme à Plasmodium falciparum sont une cause majeure de décès des enfants de moins de 5 ans en Afrique Sub-saharienne. Un traitement rapide dépend de la disponibilité de médicaments appropriés au niveau des points de prestation de service. La fréquence des ruptures de stock des commodités antipaludiques, en particuliers celles utilisées pour le paludisme grave, avait nécessité une mise à jour des hypothèses de quantification. Les données issues de la collecte de routine du PNLP de 2007 à 2012 ont été comparées à celles rapportés par d'autres pays africains et utilisées pour orienter les discussions au cours d'un atelier organisé par le PNLP et ses partenaires techniques et financiers afin de dégager un consensus national. La proportion des cas de paludisme rapportés comme grave en RDC est resté autour d'une médiane de 7% avec un domaine de variation de 6 à 9%. Hormis la proportion rapportée au Kenya (2%), les pays africains ont rapporté une proportion de cas grave variant entre 5 et 7%. Il apparaît que la proportion de 1% précédemment utilisée pour la quantification en RDC a été sous-estimée dans le contexte de la gestion des cas graves sur terrain. Un consensus s'est dégagé autour de la proportion de 5% étant entendu que des efforts de renforcement des capacités seraient déployés afin d'améliorer le diagnostic au niveau des points de prestation des services. PMID:26213595
Soins primaires aux adultes ayant des déficiences intellectuelles et développementales
Sullivan, William F.; Diepstra, Heidi; Heng, John; Ally, Shara; Bradley, Elspeth; Casson, Ian; Hennen, Brian; Kelly, Maureen; Korossy, Marika; McNeil, Karen; Abells, Dara; Amaria, Khush; Boyd, Kerry; Gemmill, Meg; Grier, Elizabeth; Kennie-Kaulbach, Natalie; Ketchell, Mackenzie; Ladouceur, Jessica; Lepp, Amanda; Lunsky, Yona; McMillan, Shirley; Niel, Ullanda; Sacks, Samantha; Shea, Sarah; Stringer, Katherine; Sue, Kyle; Witherbee, Sandra
2018-01-01
Résumé Objectif Mettre à jour les Lignes directrices consensuelles canadiennes 2011 en matière de soins primaires aux adultes ayant une déficience développementale. Méthodes Des médecins de famille et d’autres professionnels de la santé expérimentés dans les soins aux personnes ayant des DID ont examiné et synthétisé les récentes connaissances empiriques, d’écosystèmes, expertes et expérientielles. Un système a été conçu pour catégoriser la qualité des recommandations. Recommandations Les adultes ayant des DID sont un groupe hétérogène de patients qui présentent des affections médicales et des facteurs qui influent sur leur santé, qui diffèrent de ceux qui touchent les autres membres de la communauté de par leur nature, leurs manifestations, leur gravité ou leur complexité. Ces personnes nécessitent une approche de soins et des interventions adaptées à leurs besoins. Les présentes lignes directrices offrent des conseils en matière de normes de soins. Nous avons incorporé des références à des outils cliniques et à d’autres ressources pratiques. Les approches de soins décrites ici s’appliquent aussi à d’autres groupes de patients ayant un déficit cognitif ou de la communication, ou d’autres déficits des fonctions adaptatives. Conclusion À titre de fournisseurs de soins de première ligne, les médecins de famille jouent un rôle vital de promotion de la santé et de bien-être auprès des adultes ayant des DID. Ces lignes directrices peuvent les aider à prendre des décisions avec les patients et les aidants naturels. PMID:29650617
NASA Astrophysics Data System (ADS)
LeBlanc, Luc R.
Les materiaux composites sont de plus en plus utilises dans des domaines tels que l'aerospatiale, les voitures a hautes performances et les equipements sportifs, pour en nommer quelques-uns. Des etudes ont demontre qu'une exposition a l'humidite nuit a la resistance des composites en favorisant l'initiation et la propagation du delaminage. De ces etudes, tres peu traitent de l'effet de l'humidite sur l'initiation du delaminage en mode mixte I/II et aucune ne traite des effets de l'humidite sur le taux de propagation du delaminage en mode mixte I/II dans un composite. La premiere partie de cette these consiste a determiner les effets de l'humidite sur la propagation du delaminage lors d'une sollicitation en mode mixte I/II. Des eprouvettes d'un composite unidirectionnel de carbone/epoxy (G40-800/5276-1) ont ete immergees dans un bain d'eau distillee a 70°C jusqu'a leur saturation. Des essais experimentaux quasi-statiques avec des chargements d'une gamme de mixites des modes I/II (0%, 25%, 50%, 75% et 100%) ont ete executes pour determiner les effets de l'humidite sur la resistance au delaminage du composite. Des essais de fatigue ont ete realises, avec la meme gamme de mixite des modes I/II, pour determiner 1'effet de 1'humidite sur l'initiation et sur le taux de propagation du delaminage. Les resultats des essais en chargement quasi-statique ont demontre que l'humidite reduit la resistance au delaminage d'un composite carbone/epoxy pour toute la gamme des mixites des modes I/II, sauf pour le mode I ou la resistance au delaminage augmente apres une exposition a l'humidite. Pour les chargements en fatigue, l'humidite a pour effet d'accelerer l'initiation du delaminage et d'augmenter le taux de propagation pour toutes les mixites des modes I/II. Les donnees experimentales recueillies ont ete utilisees pour determiner lesquels des criteres de delaminage en statique et des modeles de taux de propagation du delaminage en fatigue en mode mixte I/II proposes dans la litterature representent le mieux le delaminage du composite etudie. Une courbe de regression a ete utilisee pour determiner le meilleur ajustement entre les donnees experimentales et les criteres de delaminage en statique etudies. Une surface de regression a ete utilisee pour determiner le meilleur ajustement entre les donnees experimentales et les modeles de taux de propagation en fatigue etudies. D'apres les ajustements, le meilleur critere de delaminage en statique est le critere B-K et le meilleur modele de propagation en fatigue est le modele de Kenane-Benzeggagh. Afin de predire le delaminage lors de la conception de pieces complexes, des modeles numeriques peuvent etre utilises. La prediction de la longueur de delaminage lors des chargements en fatigue d'une piece est tres importante pour assurer qu'une fissure interlaminaire ne va pas croitre excessivement et causer la rupture de cette piece avant la fin de sa duree de vie de conception. Selon la tendance recente, ces modeles sont souvent bases sur l'approche de zone cohesive avec une formulation par elements finis. Au cours des travaux presentes dans cette these, le modele de progression du delaminage en fatigue de Landry & LaPlante (2012) a ete ameliore en y ajoutant le traitement des chargements en mode mixte I/II et en y modifiant l'algorithme du calcul de la force d'entrainement maximale du delaminage. Une calibration des parametres de zone cohesive a ete faite a partir des essais quasi-statiques experimentaux en mode I et II. Des resultats de simulations numeriques des essais quasi-statiques en mode mixte I/II, avec des eprouvettes seches et humides, ont ete compares avec les essais experimentaux. Des simulations numeriques en fatigue ont aussi ete faites et comparees avec les resultats experimentaux du taux de propagation du delaminage. Les resultats numeriques des essais quasi-statiques et de fatigue ont montre une bonne correlation avec les resultats experimentaux pour toute la gamme des mixites des modes I/II etudiee.
Attinsounon, Cossi Angelo; Hounnankan, Cossi Athanase; Dovonou, Comlan Albert; Alassani, Cossi Adébayo; Salifou, Sourakatou
2017-01-01
Introduction L’objectif de cette étude était d’évaluer les connaissances et attitudes des relais communautaires vis-à-vis des fièvres hémorragiques à virus Ebola et Lassa et leur implication dans la mise œuvre des activités de prévention de ces maladies. Méthodes Une enquête transversale descriptive a été menée auprès des relais communautaires recrutés par tirage au sort dans 40 villages du département de la Donga. Ces relais faisaient la prise en charge à domicile des maladies respiratoires, diarrhéiques et du paludisme chez les enfants de moins de cinq ans. Un questionnaire anonyme a été administré par interview directe. Les données ont été analysées à l’aide du logiciel Epi-info 3.5.1. Résultats Au total 58 relais communautaires (RC) ont participé à cette enquête sur les 60 attendus. L’âge moyen était de 38,7±10,6 ans avec un sex-ratio de 3,5. Il y avait majoritairement trente cinq cultivateurs (60,3%) et treize revendeuses (22,4%). Quarante huit enquêtés (82,8%) reconnaissaient les deux maladies comme étant graves, mortelles et transmissibles. Les trois principales voies de transmission citées étaient le contact ou la consommation de gibiers (87,9%), le contact direct avec les personnes infectées (74,1%) ou leurs cadavres (46,6%). Les principaux moyens préventifs énumérés étaient en lien avec les voies de transmission. La fièvre (81,0%), les vomissements (81,0%) et la diarrhée (60,3%) venaient en tête des symptômes cités. Seulement vingt-deux RC (37,9%) disposaient de gants mais les utilisaient rarement pour examiner les enfants malades. Quant à la conduite à tenir devant un cas suspect de fièvre hémorragique virale Lassa ou Ebola, quarante-et-un relais communautaires (70,7%) feraient recours aux agents de santé sans toucher au malade, neuf (15,5%) feraient appel à l’ambulance et huit (13,8%) transporteraient le cas sur leur propre moto ou sur un taxi-moto vers le centre de santé le plus proche. Conclusion Le renforcement des capacités des relais communautaires sur les fièvres hémorragiques virales contribuerait à l’amélioration de leurs connaissances sur ces épidémies mortelles et à la qualité de leurs interventions dans la population. Introduction This study aimed to evaluate the knowledges and attitudes of community volunteers on Lassa and Ebola viral haemorrhagic fevers and their role in the implementation of activities for the prevention of these diseases. Methods We conducted a cross-sectional descriptive survey among community volunteers chosen by lot in 40 villages in the Donga Department. Children under five years of age with respiratory and diarrheal diseases and malaria were treated by these community volunteers in their home. An anonymous questionnaire was administered by direct interview. Data were analyzed using Epi-Info 3.5.1. Results Out of 60 community volunteers potentially participating in this survey a total of 58 effectively participated. The average age of community volunteers was 38.7 ± 10.6 years with a sex-ratio of 3.5. The majority of the community volunteers were farmers (thirty-five, 60.3%) and resellers (thirteen, 22.4%). Forty-eight respondents (82.8%) recognized the two diseases as being serious, life-threatening and transmissible. The three main routes of transmission cited were the contact with or the consumption of bushmeat (87.9%), the direct contact with infected people (74.1%) or with their corpses (46.6%). The main preventive measures listed were related to the routes of transmission. Fever (81.0%), vomiting (81.0%) and diarrhea (60.3%) were at the top of the cited symptoms. Only twenty-two community volunteers (37.9%) had gloves but they rarely used them to examine sick children. As regards the procedure to follow in case of suspected Lassa or Ebola viral haemorrhagic fever , forty-one community volunteers (70.7%) would make use of community-based health workers without touching the patient, nine (15.5%) would call for the ambulance and eight (13.8%) would take the patient to the nearest health center using their own motorcycle or a motorcycle-taxi. Conclusion Strengthening community volunteers’ capacity to manage viral hemorrhagic fevers would contribute to the improvement of their knowledge of these life-threatening epidemics and to the quality of population health interventions. PMID:28690743
NASA Astrophysics Data System (ADS)
Haguma, Didier
Il est dorenavant etabli que les changements climatiques auront des repercussions sur les ressources en eau. La situation est preoccupante pour le secteur de production d'energie hydroelectrique, car l'eau constitue le moteur pour generer cette forme d'energie. Il sera important d'adapter les regles de gestion et/ou les installations des systemes hydriques, afin de minimiser les impacts negatifs et/ou pour capitaliser sur les retombees positives que les changements climatiques pourront apporter. Les travaux de la presente recherche s'interessent au developpement d'une methode de gestion des systemes hydriques qui tient compte des projections climatiques pour mieux anticiper les impacts de l'evolution du climat sur la production d'hydroelectricite et d'etablir des strategies d'adaptation aux changements climatiques. Le domaine d'etude est le bassin versant de la riviere Manicouagan situe dans la partie centrale du Quebec. Une nouvelle approche d'optimisation des ressources hydriques dans le contexte des changements climatiques est proposee. L'approche traite le probleme de la saisonnalite et de la non-stationnarite du climat d'une maniere explicite pour representer l'incertitude rattachee a un ensemble des projections climatiques. Cette approche permet d'integrer les projections climatiques dans le probleme d'optimisation des ressources en eau pour une gestion a long terme des systemes hydriques et de developper des strategies d'adaptation de ces systemes aux changements climatiques. Les resultats montrent que les impacts des changements climatiques sur le regime hydrologique du bassin de la riviere Manicouagan seraient le devancement et l'attenuation de la crue printaniere et l'augmentation du volume annuel d'apports. L'adaptation des regles de gestion du systeme hydrique engendrerait une hausse de la production hydroelectrique. Neanmoins, une perte de la performance des installations existantes du systeme hydrique serait observee a cause de l'augmentation des deversements non productibles dans le climat futur. Des strategies d'adaptation structurale ont ete analysees pour augmenter la capacite de production et la capacite d'ecoulement de certaines centrales hydroelectriques afin d'ameliorer la performance du systeme. Une analyse economique a permis de choisir les meilleures mesures d'adaptation et de determiner le moment opportun pour la mise en oeuvre de ces mesures. Les resultats de la recherche offrent aux gestionnaires des systemes hydriques un outil qui permet de mieux anticiper les consequences des changements climatiques sur la production hydroelectrique, incluant le rendement de centrales, les deversements non productibles et le moment le plus opportun pour inclure des modifications aux systemes hydriques. Mots-cles : systemes hydriques, adaptation aux changements climatiques, riviere Manicouagan
Inhibition of DES-induced DNA adducts by diallyl sulfide: implications in liver cancer prevention.
Green, Mario; Thomas, Ronald; Gued, Lisa; Sadrud-Din, Sakeenah
2003-01-01
Diethylstilbesterol (DES) is known to cause cancer in humans and animals. Diallyl sulfide (DAS), a component of garlic, has been shown to prevent various types of cancer, presumably via metabolic modulation. Previously, we have demonstrated that DAS prevents the oxidation and reduction of DES in vitro. We hypothesize that DAS will inhibit the metabolism of DES in vivo thus preventing the formation of DES-induced DNA adducts. To test this hypothesis, five groups of five male Sprague-Dawley rats were treated as follows: the control received 0.5 ml of corn oil daily for four days. The second group received 50 mg/kg DAS daily for four days. The third group received 50 mg/kg DAS daily for four days followed by 150 mg/kg DES on day five. The fourth group received 400 mg/kg DAS on day five followed by 150 mg/kg DES. The fifth group received 150 mg/kg DES on day five. All of the rats were sacrificed on day five, 4 h after DES treatment. DNA was isolated from the liver and analyzed by 32P-post-labeling for DNA adducts. The in vitro study was performed utilizing four reactions described as follows: the control reaction contained 200 microg DNA, microsomes (346 microg protein/ml), and 10 mM DES; no oxidation co-factor (cumen hydroperoxide) was added. The second reaction, a complete oxidation system, contained 200 microg DNA, microsomes (346 microg protein/ml), 30 mM cumen hydroperoxide, and 10 mM DES. The third reaction contained 200 microg DNA, microsomes (346 microg protein/ml), 30 mM cumen hydroperoxide, 50 mM DAS, and 10 mM DES. The fourth reaction contained 200 microg DNA, microsomes (346 microg protein/ml), 30 mM cumen hydroperoxide, 100 mM DAS, and 10 mM DES. All of the in vitro reactions were buffered with 100 mM KPO4 pH 7.4 and incubated for 30 min at 37 degrees C. DNA was extracted and analyzed by 32P-post-labeling. We found that DAS inhibited the formation of DES-induced DNA adducts in a dose-dependent fashion. We have shown that DES-induced DNA adducts were inhibited in rats that received DAS pre-treatment and co-treatment with DES. These results suggest that DAS directly inhibits the metabolism of DES thus preventing the formation of DNA adducts. In addition to directly inhibiting the metabolism of DES, DAS appears to alter the expression of the metabolic machinery such that DES-induced adducts are inhibited. The inhibition of DES-induced DNA adducts by DAS may prevent the initiation of estrogen-induced cancer.
Mouse hypospadias: A critical examination and definition
Sinclair, Adriane Watkins; Cao, Mei; Shen, Joel; Cooke, Paul; Risbridger, Gail; Baskin, Laurence; Cunha, Gerald R.
2016-01-01
Hypospadias is a common malformation whose etiology is based upon perturbation of normal penile development. The mouse has been previously used as a model of hypospadias, despite an unacceptably wide range of definitions for this malformation. The current paper presents objective criteria and a definition of mouse hypospadias. Accordingly, diethylstilbestrol (DES) induced penile malformations were examined at 60 days postnatal (P60) in mice treated with DES over the age range of 12 days embryonic to 20 days postnatal (E12 to P20). DES-induced hypospadias involves malformation of the urethral meatus, which is most severe in DES E12-P10, DES P0-P10 and DES P5-P15 groups and less so or absent in the other treatment groups. A frenulum-like ventral tether between the penis and the prepuce was seen in the most severely affected DES-treated mice. Internal penile morphology was also altered in the DES E12-P10, DES P0-P10 and DES P5-P15 groups (with little effect in the other DES treatment groups). Thus, adverse effects of DES are a function of the period of DES treatment and most severe in the P0 to P10 period. In “estrogen mutant mice” (NERKI, βERKO, αERKO and AROM+) hypospadias was only seen in AROM+ male mice having genetically-engineered elevation is serum estrogen. Significantly, mouse hypospadias was only seen distally at and near the urethral meatus where epithelial fusion events are known to take place and never in the penile midshaft, where urethral formation occurs via an entirely different morphogenetic process. PMID:27068029
NASA Astrophysics Data System (ADS)
Mebarki, Fouzia
Cette etude vise a etudier la possibilite d'utiliser des materiaux composites a matrice thermoplastique pour des applications electriques comme les supports des systemes d'allumage dans les moteurs d'automobile. Nous nous interessons plus particulierement aux composites a base de polyethylene terephtalate (PET) recycle. Les isolants classiques comme le PET ne peuvent pas satisfaire toutes les exigences. L'introduction des renforts comme les fibres de verre et le mica peuvent ameliorer les caracteristiques mecaniques de ces materiaux. Toutefois, cette amelioration peut etre accompagnee d'une diminution des proprietes electriques surtout que ces materiaux doivent operer sous contraintes thermiques et electriques tres severes. Afin d'estimer la duree de vie de ces isolants, des essais de vieillissement accelere ont ete effectues a une frequence de 300Hz dans une plage de temperature allant de la temperature ambiante a 140°C. L'etude a haute temperature permettra de determiner la temperature de service des materiaux candidats. Des essais de la rupture dielectrique ont ete realises sur un grand nombre d'echantillon selon la norme ASTM D-149 relative aux mesures de rigidite dielectrique des isolants solides. Ces tests ont permis de deceler les echantillons problematiques et de verifier la qualite de ces isolants solides. Les differentes connaissances acquises lors de cette analyse ont servi a predire les performances des materiaux en service et vont permettre a la compagnie Groupe Lavergne d'apporter des ameliorations au niveau des formulations existantes et par la suite developper un materiau ayant les proprietes electriques et thermiques adequates pour ce type d'application. None None None None
Categorizing Variations of Student-Implemented Sorting Algorithms
ERIC Educational Resources Information Center
Taherkhani, Ahmad; Korhonen, Ari; Malmi, Lauri
2012-01-01
In this study, we examined freshmen students' sorting algorithm implementations in data structures and algorithms' course in two phases: at the beginning of the course before the students received any instruction on sorting algorithms, and after taking a lecture on sorting algorithms. The analysis revealed that many students have insufficient…
John Rusty Dramm; Gerry L. Jackson; Jenny Wong
2002-01-01
This report provides a general overview of current log sort yard operations in the United States, including an extensive literature review and information collected during on-site visits to several operations throughout the nation. Log sort yards provide many services in marketing wood and fiber by concentrating, merchandising, processing, sorting, and adding value to...
COST EVALUATION OF AUTOMATED AND MANUAL POST- CONSUMER PLASTIC BOTTLE SORTING SYSTEMS
This project evaluates, on the basis of performance and cost, two Automated BottleSort® sorting systems for post-consumer commingled plastic containers developed by Magnetic Separation Systems. This study compares the costs to sort mixed bales of post-consumer plastic at these t...
Belmir, R; Fejjal, N; El Omari, M; El Mazouz, S; Gharib, N; Abassi, A; Belmahi, A
2008-09-30
Les accidents électriques par haute tension (AEHT) provoquent des brûlures profondes par effet Joule le long des axes vasculo-nerveux entre les points d'entrée et de sortie, qui sont le siège de lésions délabrantes. Les Auteurs rapportent une série de dix cas d'AEHT admis au service de chirurgie réparatrice et de brûlés de l'Hôpital Ibn Sina de Rabat à travers laquelle ils étudient les caractéristiques épidémiologiques, cliniques et thérapeutiques. Tous les patients étaient des adultes de sexe masculin dont l'âge moyen était de 31 ans. Dans 70% des cas, ces brûlures étaient secondaires à un contact avec les distributeurs d'électricité avec une surface brûlée inférieure à 20%. Le traitement des lésions électrothermiques a nécessité des interventions itératives avec amputation des segments de membres nécrosés dans 70% des cas, dont les suites étaient marquées par des séquelles fonctionnelles invalidantes. La prévention des AEHT, en particulier pour les accidents du travail au sein des professions exposées, reste fondamentale.
Diethylstilbestrol (DES) and Cancer
... Genetics Services Directory Cancer Prevention Overview Research Diethylstilbestrol (DES) and Cancer On This Page What is DES? ... outlined in the table below. Fertility Problems in DES Daughters ( 7 ) Fertility Complication Hazard Ratio Percent Cumulative ...
Pringsheim, Tamara; Panagiotopoulos, Constadina; Davidson, Jana; Ho, Josephine
2012-01-01
HISTORIQUE : Au Canada, l’utilisation d’antipsychotiques, notamment les antipsychotiques de deuxième génération (ADG), a augmenté de façon considérable depuis cinq ans chez les enfants ayant des troubles de santé mentale. Ces médicaments ont le potentiel de causer de graves complications métaboliques et neurologiques lorsqu’on les utilise de manière chronique. OBJECTIF : Synthétiser les données probantes relatives aux effets secondaires métaboliques et neurologiques précis associés à l’usage d’ADG chez les enfants et fournir des recommandations probantes sur la surveillance de ces effets secondaires. MÉTHODOLOGIE : Les auteurs ont procédé à une analyse systématique des essais cliniques contrôlés des ADG auprès d’enfants. Ils ont fait des recommandations à l’égard de la surveillance de l’innocuité des ADG d’après un modèle de classification fondé sur le système GRADE (système de notation de l’évaluation et de l’élaboration des recommandations). Lorsque les données probantes n’étaient pas suffisantes, ils fondaient leurs recommandations sur le consensus et l’avis d’experts. Un groupe consensuel multidisciplinaire a analysé toutes les données probantes pertinentes et est parvenu à un consensus à l’égard des recommandations. RÉSULTATS : Les recommandations probantes portant sur la surveillance de l’innocuité des ADG figurent dans les présentes lignes directrices. Les auteurs indiquent la qualité des recommandations relatives à des examens physiques et tests de laboratoire précis à l’égard de chaque ADG à des moments déterminés. CONCLUSION : De multiples essais aléatoires et contrôlés ont permis d’évaluer l’efficacité de bon nombre des ADG utilisés pour traiter les troubles de santé mentale en pédiatrie. Toutefois, leurs avantages ne sont pas sans risques : on observe à la fois des effets secondaires métaboliques et neurologiques chez les enfants traités au moyen d’ADG. Le risque de prise de poids, d’augmentation de l’indice de masse corporelle et de taux lipidiques anormaux est plus élevé à l’utilisation d’olanzapine, suivie de la clozapine et de la quétiapine. Quant au risque d’effets secondaires neurologiques des traitements, il est plus élevé à l’utilisation de rispéridone, d’olanzapine et d’aripiprazole. Des interventions de surveillance pertinentes des effets secondaires amélioreront la qualité des soins des enfants traités à l’aide de ces médicaments. PMID:24082813
Etude aerodynamique d'un jet turbulent impactant une paroi concave
NASA Astrophysics Data System (ADS)
LeBlanc, Benoit
Etant donne la demande croissante de temperatures elevees dans des chambres de combustion de systemes de propulsions en aerospatiale (turbomoteurs, moteur a reaction, etc.), l'interet dans le refroidissement par jets impactant s'est vu croitre. Le refroidissement des aubes de turbine permet une augmentation de temperature de combustion, ce qui se traduit en une augmentation de l'efficacite de combustion et donc une meilleure economie de carburant. Le transfert de chaleur dans les au bages est influence par les aspects aerodynamiques du refroidissement a jet, particulierement dans le cas d'ecoulements turbulents. Un manque de comprehension de l'aerodynamique a l'interieur de ces espaces confinees peut mener a des changements de transfert thermique qui sont inattendus, ce qui augmente le risque de fluage. Il est donc d'interet pour l'industrie aerospatiale et l'academie de poursuivre la recherche dans l'aerodynamique des jets turbulents impactant les parois courbes. Les jets impactant les surfaces courbes ont deja fait l'objet de nombreuses etudes. Par contre des conditions oscillatoires observees en laboratoire se sont averees difficiles a reproduire en numerique, puisque les structures d'ecoulements impactants des parois concaves sont fortement dependantes de la turbulence et des effets instationnaires. Une etude experimentale fut realisee a l'institut PPRIME a l'Universite de Poitiers afin d'observer le phenomene d'oscillation dans le jet. Une serie d'essais ont verifie les conditions d'ecoulement laminaires et turbulentes, toutefois le cout des essais experimentaux a seulement permis d'avoir un apercu du phenomene global. Une deuxieme serie d'essais fut realisee numeriquement a l'Universite de Moncton avec l'outil OpenFOAM pour des conditions d'ecoulement laminaire et bidimensionnel. Cette etude a donc comme but de poursuivre l'enquete de l'aerodynamique oscillatoire des jets impactant des parois courbes, mais pour un regime d'ecoulement transitoire, turbulent, tridimensionnel. Les nombres de Reynolds utilises dans l'etude numerique, bases sur le diametre du jet lineaire observe, sont de Red = 3333 et 6667, consideres comme etant en transition vers la turbulence. Dans cette etude, un montage numerique est construit. Le maillage, le schema numerique, les conditions frontiere et la discretisation sont discutes et choisis. Les resultats sont ensuite valides avec des donnees turbulentes experimentales. En modelisation numerique de turbulence, les modeles de Moyennage Reynolds des Equations Naviers Stokes (RANS) presentent des difficultes avec des ecoulements instationnaires en regime transitionnel. La Simulation des Grandes Echelles (LES) presente une solution plus precise, mais au cout encore hors de portee pour cette etude. La methode employee pour cette etude est la Simulation des Tourbillons Detaches (DES), qui est un hybride des deux methodes (RANS et LES). Pour analyser la topologie de l'ecoulement, la decomposition des modes propres (POD) a ete egalement ete effectuee sur les resultats numeriques. L'etude a demontre d'abord le temps de calcul relativement eleve associe a des essais DES pour garder le nombre de Courant faible. Les resultats numeriques ont cependant reussi a reproduire correctement le basculement asynchrone observe dans les essais experimentaux. Le basculement observe semble etre cause par des effets transitionnels, ce qui expliquerait la difficulte des modeles RANS a correctement reproduire l'aerodynamique de l'ecoulement. L'ecoulement du jet, a son tour, est pour la plupart du temps tridimensionnel et turbulent sauf pour de courtes periodes de temps stable et independant de la troisieme dimension. L'etude topologique de l'ecoulement a egalement permit la reconaissances de structures principales sousjacentes qui etaient brouillees par la turbulence. Mots cles : jet impactant, paroi concave, turbulence, transitionnel, simulation des tourbillons detaches (DES), OpenFOAM.
NASA Astrophysics Data System (ADS)
Ahmed, Chaara El Mouez
Nous avons etudie les relations de dispersion et la diffusion des glueballs et des mesons dans le modele U(1)_{2+1} compact. Ce modele a ete souvent utilise comme un simple modele de la chromodynamique quantique (QCD), parce qu'il possede le confinement ainsi que les etats de glueballs. Par contre, sa structure mathematique est beaucoup plus simple que la QCD. Notre methode consiste a diagonaliser l'Hamiltonien de ce modele dans une base appropriee de graphes et sur reseau impulsion, afin de generer les relations de dispersion des glueballs et des mesons. Pour la diffusion, nous avons utilise la methode dependante du temps pour calculer la matrice S et la section efficace de diffusion des glueballs et des mesons. Les divers resultats obtenus semblent etre en accord avec les travaux anterieurs de Hakim, Alessandrini et al., Irving et al., qui eux, utilisent plutot la theorie des perturbations en couplage fort, et travaillent sur un reseau espace-temps.
Xu, Ran-Fang; Sun, Min-Xia; Liu, Juan; Wang, Hong; Li, Xin; Zhu, Xue-Zhu; Ling, Wan-Ting
2014-08-01
Utilizing the diethylstilbestrol (DES)-degrading bacteria to biodegrade DES is a most reliable technique for cleanup of DES pollutants from the environment. However, little information is available heretofore on the isolation of DES-degrading bacteria and their DES removal performance in the environment. A novel bacterium capable of degrading DES was isolated from the activated sludge of a wastewater treatment plant. According to its morphology, physiochemical characteristics, and 16S rDNA sequence analysis, this strain was identified as Serratia sp.. The strain was an aerobic bacterium, and it could degrade 68.3% of DES (50 mg x L(-1)) after culturing for 7 days at 30 degrees C, 150 r x min(-1) in shaking flasks. The optimal conditions for DES biodegradation by the obtained strain were 30 degrees C, 40-60 mg x L(-1) DES, pH 7.0, 5% of inoculation volume, 0 g x L(-1) of added NaCl, and 10 mL of liquid medium volume in 100 mL flask.
Le modele de Hubbard bidimensionnel a faible couplage: Thermodynamique et phenomenes critiques
NASA Astrophysics Data System (ADS)
Roy, Sebastien
Une etude systematique du modele de Hubbard en deux dimensions a faible couplage a l'aide de la theorie Auto-Coherente a Deux Particules (ACDP) dans le diagramme temperature-dopage-interaction-sauts permet de mettre en evidence l'influence des fluctuations magnetiques sur les proprietes thermodynamiques du systeme electronique sur reseau. Le regime classique renormalise a temperature finie pres du dopage nul est marque par la grandeur de la longueur de correlation de spin comparee a la longueur thermique de de Broglie et est caracterisee par un accroissement drastique de la longueur de correlation de spin. Cette croissance exponentielle a dopage nul marque la presence d'un pic de chaleur specifique en fonction de la temperature a basse temperature. Une temperature de crossover est alors associee a la temperature a laquelle la longueur de correlation de spin est egale a la longueur thermique de de Broglie. C'est a cette temperature caracteristique, ou est observee l'ouverture du pseudogap dans le poids spectral, que se situe le maximum du pic de chaleur specifique. La presence de ce pic a des consequences sur l'evolution du potentiel chimique avec le dopage lorsque l'uniformite thermodynamique est respectee. Les contraintes imposees par les lois de la thermodynamique font en sorte que l'evolution du potentiel chimique avec le dopage est non triviale. On demontre entre autres que le potentiel chimique est proportionnel a la double occupation qui est reliee au moment local. Par ailleurs, une derivation de la fonction de mise a l'echelle de la susceptibilite de spin a frequence nulle au voisinage d'un point critique marque sans equivoque la presence d'un point critique quantique en dopage pour une valeur donnee de l'interaction. Ce point critique, associe a une transition de phase magnetique en fonction du dopage a temperature nulle, induit un comportement non trivial sur les proprietes physiques du systeme a temperature finie. L'approche quantitative ACDP permet de calculer une echelle de temperature concrete pour laquelle ce point critique a des repercussions. Dans le regime critique, la longueur de correlation enregistre plutot une dependance en 1T Finalement, une synthese de ces resultats permet d'aborder une mise en application pratique de ces methodes d'analyse pour les supraconducteurs a haute temperature critique dopes aux electrons tels que le Nd2--xCe xCuO4+/-delta. Une comparaison entre les resultats theoriques et les mesures experimentales pour ce materiau est effectuee.
The determination of arsenic in estuarine waters usually involves a matrix removal and/or pre-concentration prior to analysis because of the high salt content in these waters. The salinity also produces analytical challenges in terms of interferences and instrument stability. A...
The perspectives, information and conclusions conveyed in research project abstracts, progress reports, final reports, journal abstracts and journal publications convey the viewpoints of the principal investigator and may not represent the views and policies of ORD and EPA. Concl...
Les bons conseils de la naissance à la maternelle
Rourke, Leslie; Leduc, Denis; Constantin, Evelyn; Carsley, Sarah; Rourke, James; Li, Patricia
2013-01-01
Résumé Objectif Donner un aperçu de la version 2011 du Relevé postnatal Rourke (RPR), qui comporte aussi des nouveautés dans son site web et de nouvelles initiatives connexes et qui intègre les données des ouvrages scientifiques récents sur les soins de santé préventifs à l’intention des enfants de 0 à 5 ans. Qualité des données À l’instar des versions antérieures du RPR, la nouvelle édition présente des recommandations identifiées comme se fondant sur des preuves suffisantes, acceptables ou consensuelles, selon les classifications adoptées par le Groupe d’étude canadien sur les soins de santé préventifs en 2011. Message principal De nouveaux renseignements et des recommandations sont présentés concernant la surveillance de la croissance, la nutrition et la vaccination contre la varicelle, les pneumocoques, les méningocoques et le rotavirus. Il y a maintenant de bonnes données probantes en faveur de l’adaptation canadienne des courbes de croissance de l’Organisation mondiale de la Santé, du dépistage universel des problèmes d’audition chez le nouveau-né et du recours à des stratégies de réduction de la douleur liée à la vaccination. On a mis à jour les conseils anticipatoires concernant la sécurité durant le sommeil, la supervision de la santé des enfants en foyer d’accueil, le trouble du spectre de l’alcoolisation fœtale, les facteurs de risque nécessitant le dépistage du plomb et de l’anémie, les soins dentaires et la santé buccale. Parmi les nouvelles rubriques dans le site web du RPR, on peut mentionner une section présentant des ressources pour les parents, des modifications à l’intention de populations particulières, comme les personnes vivant au Nunavut, une version du RPR qui met en évidence en un coup d’œil les modifications à la version de 2009 et une expansion de la fonction d’exploration du RPR accompagnée des hyperliens connexes menant aux renseignements pertinents. On peut aussi avoir accès au RPR sous forme d’une page par visite. Le Collège des médecins de famille du Canada et la Société canadienne de pédiatrie ont donné leur aval au RPR de 2011. Les versions nationale et ontarienne sont disponibles en français et en anglais. Conclusion Le RPR de 2011 est un outil pratique, mis à jour, fondé sur des données probantes de transposition du savoir concernant les soins de santé préventifs aux enfants de la naissance à l’âge de 5 ans. Il propose des ressources exhaustives dans le web à l’intention des professionnels de la santé, des étudiants, des résidents et des parents.
Werner, Justyna
2018-05-15
Ionic liquid ultrasound-assisted dispersive liquid-liquid microextraction based on solidification of the aqueous phase was used for preconcentration of Ni 2+ , Co 2+ , Cd 2+ , Cu 2+ , Pb 2+ in natural water samples prior to liquid chromatography with UV detection. In the proposed method, the ammonium pyrrolidinedithiocarbamate was used as a complexing agent and the phosphonium ionic liquid trihexyl(tetradecyl)phosphonium bis[(2,4,4-trimethyl)pentyl]phosphinate (Cyphos IL 104) was used as an extractant. Ultrasound energy was used to disperse the extractant in the aqueous phase. After microextraction, the ionic liquid and aqueous phases were separated by centrifugation. Then the aqueous phase was frozen and the lighter than water ionic liquid phase containing metal ions complexes with pyrrolidinedithiocarbamate was separated and dissolved in a small volume of methanol prior to injection into the liquid chromatograph. Several parameters including the volume of extractant, the pH of the sample, the concentration of complexing agent, the time of ultrasound energy treatment, the time and speed of centrifugation and the effect of ionic strength were optimized. Under the optimized conditions (10 µL of Cyphos IL 104, pH = 5, 0.3% w/v ammonium pyrrolidinedithiocarbamate, 60 s of ultrasound use, 5 min/5000 rpm (2516×g) of centrifugation, 2.0 mg of NaCl), preconcentration factors were 211, 210, 209, 207 and 211 for Ni 2+ , Co 2+ , Cd 2+ , Cu 2+ and Pb 2+ respectively. Linearity was observed in the ranges 0.2-75.0 µg L -1 for Pb 2+ , Cd 2+ , Co 2+ and 0.5-100.0 µg L -1 for Cu 2+ , Ni 2+ . The limits of detection were 0.03 µg L -1 for Ni 2+ , 0.03 µg L -1 for Co 2+ , 0.03 µg L -1 for Cd 2+ , 0.02 µg L -1 for Cu 2+ , 0.02 µg L -1 for Pb 2+ , respectively. The accuracy of this method was evaluated by preconcentration and determination of Ni 2+ , Co 2+ , Cd 2+ , Cu 2+ , Pb 2+ in certified reference materials (TMRAIN-04 and NIST 1643e) with the recovery values in the range of 97-102%. The presented method has been successfully applied for the determination of analytes in natural water samples (river and lake waters). Copyright © 2018 Elsevier B.V. All rights reserved.
Controle optique de qubits lies a des centres isoelectroniques d'azote dans le GaAs
NASA Astrophysics Data System (ADS)
Ethier-Majcher, Gabriel
Le traitement de l'information quantique est un domaine de recherche actuellement en pleine effervescence car il laisse entrevoir une revolution dans notre facon de traiter et d'echanger de l'information. D'une part, l'ordinateur quantique promet de resoudre des problemes comme la factorisation d'un polynome de facon beaucoup plus efficace qu'un ordinateur classique. D'autre part, les communications quantiques promettent l'echange d'information de facon fondamentalement inviolable. Afin de tirer pleinement profit de ces nouvelles technologies, il sera avantageux de construire des reseaux quantiques. Dans un tel reseau, des processeurs quantiques, les noeuds, seront connectes par des photons voyageant dans des fibres optiques. Les reseaux quantiques permettront de deployer les communications quantiques a grande echelle et de creer des super-ordinateurs quantiques. La realisation de reseaux quantiques necessitera des interfaces optiques pouvant echanger l'information de facon coherente entre un qubit (bit d'information quantique) et un photon. L'implementation de telles interfaces dans un systeme physique s'avere un important defi scientifique et technologique. Or, les systemes actuellement envisages a cette fin souffrent d'un faible couplage avec la lumiere ou encore de grandes inhomogeneites, constituant des obstacles a la realisation de reseaux a grande echelle. Dans cette these, le potentiel des centres isoelectroniques pour realiser des interfaces optiques est evalue. Deux types de qubits lies a des paires d'azote dans le GaAs sont consideres : les qubits excitoniques et les qubits de spin electronique, controlables par l'intermediaire d'excitons charges. Le controle optique complet des qubits excitoniques est demontre, ce qui constitue la premiere realisation du genre dans les centres isoelectroniques. L'observation d'excitons charges dans ce systeme, liant a la fois des trous lourds et des trous legers, laisse entrevoir de nouvelles possibilites afin de manipuler des spins electroniques. Les excitons et excitons charges lies aux paires d'azote sont etudies par la photoluminescence resolue spatialement. Le controle des qubits excitoniques est realisee a l'aide d'impulsions laser resonantes avec un etat excitonique et l'etat du qubit est lu par sa fluorescence en resonance. Une experience de rotations de Rabi est realisee pour demontrer un controle sur la population du qubit. Cette experience permet d'extraire un moment dipolaire moyen de 27 D pour l'exciton.
NASA Astrophysics Data System (ADS)
Salissou, Yacoubou
L'objectif global vise par les travaux de cette these est d'ameliorer la caracterisation des proprietes macroscopiques des materiaux poreux a structure rigide ou souple par des approches inverses et indirectes basees sur des mesures acoustiques faites en tube d'impedance. La precision des approches inverses et indirectes utilisees aujourd'hui est principalement limitee par la qualite des mesures acoustiques obtenues en tube d'impedance. En consequence, cette these se penche sur quatre problemes qui aideront a l'atteinte de l'objectif global precite. Le premier probleme porte sur une caracterisation precise de la porosite ouverte des materiaux poreux. Cette propriete en est une de passage permettant de lier la mesure des proprietes dynamiques acoustiques d'un materiau poreux aux proprietes effectives de sa phase fluide decrite par les modeles semi-phenomenologiques. Le deuxieme probleme traite de l'hypothese de symetrie des materiaux poreux selon leur epaisseur ou un index et un critere sont proposes pour quantifier l'asymetrie d'un materiau. Cette hypothese est souvent source d'imprecision des methodes de caracterisation inverses et indirectes en tube d'impedance. Le critere d'asymetrie propose permet ainsi de s'assurer de l'applicabilite et de la precision de ces methodes pour un materiau donne. Le troisieme probleme vise a mieux comprendre le probleme de transmission sonore en tube d'impedance en presentant pour la premiere fois un developpement exact du probleme par decomposition d'ondes. Ce developpement permet d'etablir clairement les limites des nombreuses methodes existantes basees sur des tubes de transmission a 2, 3 ou 4 microphones. La meilleure comprehension de ce probleme de transmission est importante puisque c'est par ce type de mesures que des methodes permettent d'extraire successivement la matrice de transfert d'un materiau poreux et ses proprietes dynamiques intrinseques comme son impedance caracteristique et son nombre d'onde complexe. Enfin, le quatrieme probleme porte sur le developpement d'une nouvelle methode de transmission exacte a 3 microphones applicable a des materiaux ou systemes symetriques ou non. Dans le cas symetrique, on montre que cette approche permet une nette amelioration de la caracterisation des proprietes dynamiques intrinseques d'un materiau. Mots cles. materiaux poreux, tube d'impedance, transmission sonore, absorption sonore, impedance acoustique, symetrie, porosite, matrice de transfert.
Dissociation in bipolar disorder: Relationships between clinical variables and childhood trauma.
Hariri, Aytül Gursu; Gulec, Medine Yazici; Orengul, Fatma Fariha Cengiz; Sumbul, Esra Aydin; Elbay, Rumeysa Yeni; Gulec, Huseyin
2015-09-15
The dissociative experiences of patients with bipolar disorder (BD) differ from those of patients with other psychiatric disorders with regard to certain features. The primary goal of this study was to evaluate the relationship between the clinical variables of BD and childhood trauma using the factor structure, psychometric features, and potential subdimensions of the Dissociative Experience Scale (DES). This study included 200 BD patients who were in a remission period and 50 healthy volunteers. The BD patients were recruited from two psychiatry clinic departments in Turkey. The sociodemographic data of the two groups and their scores on the DES and Childhood Trauma Questionnaire (CTQ)-28 were compared. The overall DES scores and the scores for each DES item accurately and reliably measured dissociation in the BD patients (item-total correlation r scores: >0.20, Cronbach's alpha: 0.95), and a factor analysis revealed two subdimensions of the DES for BD: identity confusion/alteration (SubDES-1) and amnesia and depersonalization/derealization (SubDES-2). Although age at onset of BD was significantly correlated with both subdimensions, illness duration was significantly correlated only with the SubDES-2. Of all the subjects, 19.5% (39/200 patients) were identified as having dissociative experiences by the DES-Taxon (DES-T), and subjects in this subscale (DES-T-positive) had significantly higher total scores on the CTQ-28 as well as higher scores on each subgroup of this scale. The highest CTQ-28 subgroup score was emotional neglect, which was followed by emotional abuse and physical neglect and then sexual abuse and physical abuse. There was a significant correlation between total scores on the CTQ-28 and SubDES-2 but none of the CTQ-28 subscale scores was significantly correlated with either SubDES-1 or SubDES-2. The DES sufficiently and reliably identified the experience of dissociative symptoms on the part of BD patients, and a factor analysis revealed two subdimensions of BD on this scale. In particular, DES-T-positive subjects experienced a greater amount of childhood trauma and, as a result, had an earlier age at onset of BD. Additionally, SubDES-2, which was associated with amnesia and depersonalization/derealization, was closely related to illness duration. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Bretin, Remy
L'endommagement par fatigue des materiaux est un probleme courant dans de nombreux domaines, dont celui de l'aeronautique. Afin de prevenir la rupture par fatigue des materiaux il est necessaire de determiner leur duree de vie en fatigue. Malheureusement, dues aux nombreuses heterogeneites presentes, la duree de vie en fatigue peut fortement varier entre deux pieces identiques faites dans le meme materiau ayant subi les memes traitements. Il est donc necessaire de considerer ces heterogeneites dans nos modeles afin d'avoir une meilleure estimation de la duree de vie des materiaux. Comme premiere etape vers une meilleure consideration des heterogeneites dans nos modeles, une etude en elasticite lineaire de l'influence des orientations cristallographiques sur les champs de deformations et de contraintes dans un polycristal a ete realisee a l'aide de la methode des elements finis. Des correlations ont pu etre etablies a partir des resultats obtenus, et un modele analytique en elasticite lineaire prenant en compte les distributions d'orientations cristallographiques et les effets de voisinage a pu etre developpe. Ce modele repose sur les bases des modeles d'homogeneisation classique, comme le schema auto-coherent, et reprend aussi les principes de voisinage des automates cellulaires. En prenant pour reference les resultats des analyses elements finis, le modele analytique ici developpe a montre avoir une precision deux fois plus grande que le modele auto-coherent, quel que soit le materiau etudie.
Contribution a l'etude et au developpement de nouvelles poudres de fonte
NASA Astrophysics Data System (ADS)
Boisvert, Mathieu
L'obtention de graphite libre dans des pieces fabriquees par metallurgie des poudres (M/P) est un defi auquel plusieurs chercheurs se sont attardes. En effet, la presence de graphite apres frittage ameliore l'usinabilite des pieces, permettant donc de reduire les couts de production, et peut aussi engendrer une amelioration des proprietes tribologiques. L'approche utilisee dans cette these pour tenter d'obtenir du graphite libre apres frittage est par l'utilisation de nouvelles poudres de fontes atomisees a l'eau. L'atomisation a l'eau etant un procede de production de poudres relativement peu couteux qui permet de grandes capacites de production, le transfert des decouvertes de ce doctorat vers des applications industrielles sera donc economiquement plus favorable. En plus de l'objectif d'obtenir du graphite libre apres frittage, un autre aspect important des travaux est le controle de la morphologie du graphite libre apres frittage. En effet, il est connu dans la litterature des fontes coulees/moulees que la morphologie du graphite influencera les proprietes des fontes, ce qui est aussi vrai pour les pieces de M/P. Les fontes ductiles, pour lesquelles le graphite est sous forme de nodules spheroidaux isoles les uns des autres, possedent des proprietes mecaniques superieures aux fontes grises pour lesquelles le graphite est sous forme lamellaire et continu dans la matrice. Les resultats presentes dans cette these montrent qu'il est possible, dans des melanges contenant des poudres de fontes, d'avoir un controle sur la morphologie du graphite et donc sur les proprietes des pieces. Le controle de la morphologie du graphite a principalement ete realise par le type de frittage et le phenomene de diffusion " uphill " du carbone cause par des gradients en silicium. En effet, pour les frittages en phase solide, tous les nodules de graphite sont presents a l'interieur des grains de poudre apres frittage. Pour les frittages en phase liquide, l'intensite de la diffusion " uphill " permet de conserver plus ou moins de graphite nodulaire a l'interieur des regions riches en silicium, alors que le reste du graphite precipite sous forme lamellaire/vermiculaire dans les regions interparticulaires. L'etude des poudres de fontes et la recherche des mecanismes regissant la morphologie du graphite dans les fontes coulees/moulees nous ont amenes a produire des poudres de fontes traitees au magnesium avant l'atomisation. Plusieurs resultats fondamentaux ont ete obtenus de la caracterisation des poudres traitees au magnesium et de leur comparaison avec des poudres de chimies similaires non traitees au magnesium. D'abord, il a ete possible d'observer des bifilms d'oxyde de silicium dans la structure du graphite primaire d'une poudre de fonte grise hypereutectique. Il s'agit des premieres images montrant la structure double de ces defauts, venant ainsi appuyer la theorie elaboree par le professeur John Campbell. Ensuite, il a ete montre que le traitement au magnesium forme une atmosphere protectrice gazeuse autogeneree qui empeche l'oxydation de la surface du bain liquide et donc, la formation et l'entrainement des bifilms. Le role du magnesium sur la morphologie du graphite est de diminuer le soufre en solution en formant des precipites de sulfure de magnesium et ainsi d'augmenter l'energie d'interface graphite-liquide. En reponse a cette grande energie d'interface graphite-liquide, le graphite cherche a minimiser son ratio surface/volume, ce qui favorise la formation de graphite spheroidal. De plus, deux types de germination ont ete observes dans la poudre de fonte hypereutectique traitee au magnesium. Le premier type est une germination heterogene sur un nombre limite de particules faites de magnesium, d'aluminium, de silicium et d'oxygene. Le deuxieme type est une germination homogene des nodules dans certaines regions du liquide plus riches en silicium. L'observation du centre reel tridimensionnel, en microscopie electronique en transmission en haute resolution, d'un des nodules ayant subi une germination homogene a permis de confirmer que le mode de croissance du graphite spheroidal se produit selon le modele de la croissance en feuille de chou. (Abstract shortened by ProQuest.).
NASA Astrophysics Data System (ADS)
Fournier, Marie-Claude
Une caracterisation des emissions atmospheriques provenant des sources fixes en operation, alimentees au gaz et a l'huile legere, a ete conduite aux installations visees des sites no.1 et no.2. La caracterisation et les calculs theoriques des emissions atmospheriques aux installations des sites no.1 et no.2 presentent des resultats qui sont en dessous des valeurs reglementaires pour des conditions d'operation normales en periode hivernale et par consequent, a de plus fortes demandes energetiques. Ainsi, pour une demande energetique plus basse, le taux de contaminants dans les emissions atmospheriques pourrait egalement etre en dessous des reglementations municipales et provinciales en vigueur. Dans la perspective d'une nouvelle reglementation provinciale, dont les termes sont discutes depuis 2005, il serait souhaitable que le proprietaire des infrastructures visees participe aux echanges avec le Ministere du Developpement Durable, de l'Environnement et des Parcs (MDDEP) du Quebec. En effet, meme si le principe de droit acquis permettrait d'eviter d'etre assujetti a la nouvelle reglementation, l'application de ce type de principe ne s'inscrit pas dans ceux d'un developpement durable. L'âge avance des installations etudiees implique la planification d'un entretien rigoureux afin d'assurer les conditions optimales de combustion en fonction du type de combustible. Des tests de combustion sur une base reguliere sont donc recommandes. Afin de supporter le processus de suivi et d'evaluation de la performance environnementale des sources fixes, un outil d'aide a la gestion de l'information environnementale a ete developpe. Dans ce contexte, la poursuite du developpement d'un outil d'aide a la gestion de l'information environnementale faciliterait non seulement le travail des personnes affectees aux inventaires annuels mais egalement le processus de communication entre les differents acteurs concernes tant intra- qu'inter-etablissement. Cet outil serait egalement un bon moyen pour sensibiliser le personnel a leur consommation energetique ainsi qu'a leur role dans la lutte contre les emissions polluantes et les gaz a effets de serre. En outre, ce type d'outil a pour principale fonction de generer des rapports dynamiques pouvant s'adapter a des besoins precis. Le decoupage coherent de l'information associe a un developpement par modules offre la perspective d'application de l'outil pour d'autres types d'activites. Dans ce cas, il s'agit de definir la part commune avec les modules existants et planifier les activites de developpement specifiques selon la meme demarche que celle presentee dans le present document.
Application of visible spectroscopy in waste sorting
NASA Astrophysics Data System (ADS)
Spiga, Philippe; Bourely, Antoine
2011-10-01
Today, waste recycling, (bottles, papers...), is a mechanical operation: the waste are crushed, fused and agglomerated in order to obtain new manufactured products (e.g. new bottles, clothes ...). The plastics recycling is the main application in the color sorting process. The colorless plastics recovered are more valuable than the colored plastics. Other emergent applications are in the paper sorting, where the main goal is to sort dyed paper from white papers. Up to now, Pellenc Selective Technologies has manufactured color sorting machines based on RGB cameras. Three dimensions (red, green and blue) are no longer sufficient to detect low quantities of dye in the considered waste. In order to increase the efficiency of the color detection, a new sorting machine, based on visible spectroscopy, has been developed. This paper presents the principles of the two approaches and their difference in terms of sorting performance, making visible spectroscopy a clear winner.
MetaSort untangles metagenome assembly by reducing microbial community complexity
Ji, Peifeng; Zhang, Yanming; Wang, Jinfeng; Zhao, Fangqing
2017-01-01
Most current approaches to analyse metagenomic data rely on reference genomes. Novel microbial communities extend far beyond the coverage of reference databases and de novo metagenome assembly from complex microbial communities remains a great challenge. Here we present a novel experimental and bioinformatic framework, metaSort, for effective construction of bacterial genomes from metagenomic samples. MetaSort provides a sorted mini-metagenome approach based on flow cytometry and single-cell sequencing methodologies, and employs new computational algorithms to efficiently recover high-quality genomes from the sorted mini-metagenome by the complementary of the original metagenome. Through extensive evaluations, we demonstrated that metaSort has an excellent and unbiased performance on genome recovery and assembly. Furthermore, we applied metaSort to an unexplored microflora colonized on the surface of marine kelp and successfully recovered 75 high-quality genomes at one time. This approach will greatly improve access to microbial genomes from complex or novel communities. PMID:28112173
Ubiquitin-dependent sorting of integral membrane proteins for degradation in lysosomes
Piper, Robert C.
2007-01-01
Summary The pathways that deliver newly synthesized proteins that reside in lysosomes are well understood by comparison with our knowledge of how integral membrane proteins are sorted and delivered to the lysosome for degradation. Many membrane proteins are sorted to lysosomes following ubiquitination, which provides a sorting signal that can operate for sorting at the TGN (trans-Golgi network), at the plasma membrane or at the endosome for delivery into lumenal vesicles. Candidate multicomponent machines that can potentially move ubiquitinated integral membrane cargo proteins have been identified, but much work is still required to ascertain which of these candidates directly recognizes ubiquitinated cargo and what they do with cargo after recognition. In the case of the machinery required for sorting into the lumenal vesicles of endosomes, other functions have also been determined including a link between sorting and movement of endosomes along microtubules. PMID:17689064
Strategies facilitant les tests en pre-certification pour la robustesse a l'egard des radiations =
NASA Astrophysics Data System (ADS)
Souari, Anis
Les effets des radiations cosmiques sur l'electronique embarquee preoccupent depuis. quelques decennies les chercheurs interesses par la robustesse des circuits integres. Plusieurs. recherches ont ete menees dans cette direction, principalement pour les applications spatiales. ou lâenvironnement de leur deploiement est hostile. En effet, ces environnements sont denses. en termes de particules qui, lorsquâelles interagissent avec les circuits integres, peuvent. mener a leur dysfonctionnement, voir meme a leur destruction. De plus, les effets des. radiations sâaccentuent pour les nouvelles generations des circuits integres ou la diminution. de la taille des transistors et lâaugmentation de la complexite de ces circuits augmentent la. probabilite dâapparition des anomalies et par consequence la croissance des besoins de test. Lâexpansion de lâelectronique grand public (commercial off-the-shelf, COTS) et lâadoption. de ces composants pour des applications critiques comme les applications avioniques et. spatiales incitent egalement les chercheurs a doubler les efforts de verification de la fiabilite. de ces circuits. Les COTS, malgre leurs meilleures caracteristiques en comparaison avec les. circuits durcis tolerants aux radiations qui sont couteux et en retard en termes de technologie. utilisee, sont vulnerables aux radiations. Afin dâameliorer la fiabilite de ces circuits, une evaluation de leur vulnerabilite dans les. differents niveaux dâabstraction du flot de conception est recommandee. Ceci aide les. concepteurs a prendre les mesures de mitigation necessaires sur le design au niveau. dâabstraction en question. Enfin, afin de satisfaire les exigences de tolerance aux pannes, des. tests tres couteux de certification, obtenus a lâaide de bombardement de particules (protons, neutrons, etc.), sont necessaires. Dans cette these, nous nous interessons principalement a definir une strategie de precertification. permettant dâevaluer dâune facon realiste la sensibilite des circuits integres face. aux effets des radiations afin dâeviter dâenvoyer des circuits non robustes a la phase tres. couteuse de la certification. Les circuits cibles par nos travaux sont les circuits integres. programmables par lâusager (FPGA) a base de memoire SRAM et le type de pannes ciblees, causees par les radiations, est les SEU (single event upset) consistant a un basculement de. lâetat logique dâun element de memoire a son complementaire. En effet, les FPGA a base de. memoire SRAM sont de plus en plus demandes par la communaute de lâaerospatial grace a. leurs caracteristiques de prototypage rapide et de reconfiguration sur site mais ils sont. vulnerables face aux radiations ou les SEU sont les pannes les plus frequentes dans les. elements de memoire de type SRAM. Nous proposons une nouvelle approche dâinjection de. pannes par emulation permettant de mimer les effets des radiations sur la memoire de. configuration des FPGA et de generer des resultats les plus fideles possibles des resultats des. tests de certification. Cette approche est basee sur la consideration de la difference de. sensibilite des elements de memoire de configuration lorsquâils sont a lâetat '1' et a lâetat '0', observee sous des tests acceleres sous faisceaux de protons au renomme laboratoire. TRIUMF, dans la procedure de generation des sequences de test dans le but de mimer la. distribution des pannes dans la memoire de configuration. Les resultats des experimentations. de validation montrent que la strategie proposee est efficace et genere des resultats realistes. Ces resultats revelent que ne pas considerer la difference de sensibilite peut mener a une. sous-estimation de la sensibilite des circuits face aux radiations. Dans la meme optique dâoptimisation de la procedure dâinjection des pannes par emulation, a. savoir le test de pre-certification, nous proposons une methodologie permettant de maximiser. la detection des bits critiques (bits provoquant une defaillance fonctionnelle sâils changent. dâetat) pour un nombre bien determine de SEU (qui est le modele de pannes adopte) ou de. maximiser la precision de lâestimation de nombre des bits critiques. Pour ce faire, une. classification des bits de configuration en differents ensembles est tout dâabord mise en. oeuvre, selon leur contenu, les ressources quâils configurent et leur criticite. Ensuite, une. evaluation de la sensibilite de chaque ensemble est accomplie. Enfin, la priorisation. dâinjection des pannes dans les ensembles les plus sensibles est recommandee. Plusieurs. scenarios dâoptimisation dâinjection des pannes sont proposes et les resultats sont compares. avec ceux donnes par la methode conventionnelle dâinjection aleatoire des pannes. La. methodologie dâoptimisation proposee assure une amelioration de plus de deux ordres de. grandeur. Une derniere approche facilitant lâevaluation de la sensibilite des bits configurant les LUT. (look up table) de FPGA, les plus petites entites configurables du FPGA permettant. dâimplementer des fonctions combinatoires, utilises par un design est presentee. Elle permet. lâidentification facile et sans cout en termes dâutilisation du materiel ou dâoutils externes des. bits des LUT. Lâapproche proposee est simple et efficace, offrant une couverture de pannes. de 100 % et applicable aux nouvelles generations des FPGA de Xilinx. Les approches proposees contribuent a repondre aux exigences du cahier des charges de cette. these et a achever les objectifs definis. Le realisme et la maximisation de lâestimation de la. vulnerabilite des circuits sous test offerts par les nouvelles approches assurent le. developpement dâune strategie de test en pre-certification efficace. En effet, la premiere. approche dâinjection de pannes considerant la difference de sensibilite relative des elements. de memoire selon leur contenu genere des resultats donnant une erreur relative atteignant. 3.1 % quand compares aux resultats obtenus a TRIUMF alors que lâerreur relative donnee. par la comparaison des resultats dâune injection conventionnelle aleatoire de pannes avec. ceux de TRIUMF peut atteindre la valeur de 75 %. De plus, lâapplication de cette approche a. des circuits plus conventionnels montre que 2.3 fois plus dâerreurs sont detectees en. comparaison avec lâinjection aleatoire des pannes. Ceci suggere que ne pas considerer la. difference de sensibilite relative dans la procedure dâemulation peut mener a une sousestimation. de la sensibilite du design face aux radiations. Les resultats de la deuxieme. approche proposee ont ete aussi compares aux resultats dâune injection aleatoire de pannes. Lâapproche proposee, maximisant le nombre des bits critiques inverses, permet dâatteindre. un facteur dâacceleration de 108 de la procedure dâinjection des pannes en comparaison a. lâapproche aleatoire. Elle permet aussi de minimiser lâerreur dâestimation du nombre des bits. critiques pour atteindre une valeur de ±1.1 % calculee pour un intervalle de confiance de. 95 % tandis que la valeur dâerreur dâestimation des bits critiques generee par lâapproche. aleatoire dâinjection des pannes pour le meme intervalle de confiance peut atteindre ±8.6 %. Enfin, la derniere approche proposee dâinjection de pannes dans les LUT se distingue des. autres approches disponibles dans la litterature par sa simplicite tout en assurant une. couverture maximale de pannes de 100 %. En effet, lâapproche proposee est independante. des outils externes permettant dâidentifier les bits configurant les LUT qui sont obsoletes ou. ne supportent pas les nouvelles generations des FPGA. Elle agit directement sur les fichiers. generes par lâoutil de synthese adopte.
Is it time to revisit the log-sort yard?
John Dramm; Gerry Jackson
2000-01-01
Log-sort yards provide better utilization and marketing with improved value recovery of currently available timber resources in North America. Log-sort yards provide many services in marketing wood and fiber by concentrating, merchandising, manufacturing, sorting, and adding value to logs. Such operations supply forest products firms with desired raw materials, which...
Word Sorts for General Music Classes
ERIC Educational Resources Information Center
Cardany, Audrey Berger
2015-01-01
Word sorts are standard practice for aiding children in acquiring skills in English language arts. When included in the general music classroom, word sorts may aid students in acquiring a working knowledge of music vocabulary. The author shares a word sort activity drawn from vocabulary in John Lithgow's children's book "Never Play…
Rowan-Legg, Anne
2017-01-01
Résumé Les familles des militaires font face à de nombreux facteurs de stress, tels que les réinstallations fréquentes, les longues pério des de séparation familiale, l’isolement géographique du réseau de soutien de la famille élargie et le déploiement en zones très dangereuses. Les enfants et les adolescents des familles des militaires vivent les mêmes trajectoires développementales et motivationnelles que leurs homologues civils, mais ils sont également aux prises avec des pressions et des facteurs de stress liés à leur développement qui sont inhabituels et qui leur sont imposés par les exigences de la vie militaire. Les effets de la vie militaire sur les familles et les enfants commencent à être admis et mieux caractérisés. Il est essentiel de comprendre les préoccupations propres aux enfants et aux adolescents des familles des militaires et de mobiliser les ressources nécessaires pour les soutenir afin de répondre à leurs besoins en matière de santé.
Mouse hypospadias: A critical examination and definition.
Sinclair, Adriane Watkins; Cao, Mei; Shen, Joel; Cooke, Paul; Risbridger, Gail; Baskin, Laurence; Cunha, Gerald R
2016-12-01
Hypospadias is a common malformation whose etiology is based upon perturbation of normal penile development. The mouse has been previously used as a model of hypospadias, despite an unacceptably wide range of definitions for this malformation. The current paper presents objective criteria and a definition of mouse hypospadias. Accordingly, diethylstilbestrol (DES) induced penile malformations were examined at 60 days postnatal (P60) in mice treated with DES over the age range of 12 days embryonic to 20 days postnatal (E12-P20). DES-induced hypospadias involves malformation of the urethral meatus, which is most severe in DES E12-P10, DES P0-P10 and DES P5-P15 groups, and less so or absent in the other treatment groups. A frenulum-like ventral tether between the penis and the prepuce was seen in the most severely affected DES-treated mice. Internal penile morphology was also altered in the DES E12-P10, DES P0-P10 and DES P5-P15 groups (with little effect in the other DES treatment groups). Thus, adverse effects of DES are a function of the period of DES treatment and most severe in the P0-P10 period. In "estrogen mutant mice" (NERKI, βERKO, αERKO and AROM+) hypospadias was only seen in AROM+ male mice having genetically-engineered elevation is serum estrogen. Significantly, mouse hypospadias was only seen distally at and near the urethral meatus where epithelial fusion events are known to take place and never in the penile midshaft, where urethral formation occurs via an entirely different morphogenetic process. Copyright © 2016 International Society of Differentiation. Published by Elsevier B.V. All rights reserved.
Lignes directrices sur la prise en charge en soins primaires des céphalées chez l’adulte
Becker, Werner J.; Findlay, Ted; Moga, Carmen; Scott, N. Ann; Harstall, Christa; Taenzer, Paul
2015-01-01
Résumé Objectif Accroître l’utilisation d’approches éclairées par des données probantes pour diagnostiquer, investiguer et traiter en soins primaires les céphalées des patients. Qualité des données Une recherche documentaire exhaustive a été effectuée pour trouver des lignes directrices et des révisions systématiques publiées entre janvier 2000 et mai 2011. La grille d’évaluation de la qualité des recommandations pour la pratique clinique AGREE a servi à l’analyse critique des lignes directrices. Les 6 guides de pratique clinique de la plus grande qualité ont servi de base dans le processus d’adaptation. Message principal Un groupe d’élaboration multidisciplinaire de professionnels des soins primaires ont formulé 91 recommandations précises à l’aide d’un processus consensuel. Les recommandations portent sur le diagnostic, l’investigation et la prise en charge de la migraine, de la céphalée de tension, de la céphalée due à une surmédication et de la céphalée vasculaire de Horton. Conclusion Un guide de pratique clinique adapté au contexte des soins de santé au Canada a été produit en suivant un processus d’adaptation de lignes directrices dans le but d’aider les professionnels de toutes les disciplines des soins primaires à dispenser des soins éclairés par des données probantes aux patients souffrant de céphalées.
Les Cicatrices Retractiles Post-Brulures Du Membre Inferieur Chez L’Enfant
Sankale, A.A.; Manyacka Ma Nyemb, P.; Coulibaly, N.F.; Ndiaye, A.; Ndoye, M.
2010-01-01
Summary Il s'agit d'une étude faisant ressortir les aspects épidémiologiques, cliniques et thérapeutiques des séquelles de brûlures du membre inférieur chez l'enfant, à propos de 42 cas colligés au service de chirurgie infantile de l'Hôpital Aristide Le Dantec (Sénégal). L'âge moyen retrouvé est de 5 ans et 3 mois, et le sex-ratio garçons/filles de 1,8/1. La brûlure thermique est causée par une flamme dans 33% des cas, par un liquide chaud dans 21% des cas, et par des braises dans 21% des cas. Les cicatrices rétractiles intéressent le genou et le creux poplité dans 47% des cas et le pied dans 45% des cas. Elles sont bilatérales dans 21% des cas, et concernent une autre localisation associée dans 21% des cas. Quant aux brides, 21% ont bénéficié d'une chirurgie, avec un délai moyen de 3 ans et 2 mois après la brûlure. Cette procédure chirurgicale consiste en une plastie en Z dans 91% des cas, à laquelle est associée une greffe de peau dans 54% des cas. Une rééducation fonctionnelle est pratiquée chez 54% des opérés. Parallèlement aux données de la littérature, nos résultats montrent que l'optimisation de la prise en charge passe par une meilleure prévention des accidents domestiques et une bonne codification thérapeutique. PMID:21991202
Radar response to crop residue cover and tillage application on postharvest agricultural surfaces
NASA Astrophysics Data System (ADS)
McNairn, Heather
Les informations sur les pratiques de conservation des sols comme le labourage et la gestion des residus de culture sont requises afin d'estimer avec exactitude les risques d'erosion des sols. Quoique les micro-ondes soient sensibles aux conditions d'humidite et aux proprietes geometriques des surfaces, il n'en demeure pas moins que l'on connait encore peu sur la sensibilite des micro-ondes polarisees lineaires ou des parametres polarimetriques du ROS en fonction des caracteristiques des residus. A partir de donnees prises a l'aide d'un diffusometre monte sur un camion en 1996 et lors d'une mission SIR-C menee en 1994, cette recherche a demontre que les micro-ondes sont sensibles a la fois a la quantite et au type de couverture de residus, de meme qu'a la teneur en eau des residus. La reponse des polarisations croisees lineaires et de plusieurs parametres polarimetriques, incluant la hauteur pedestre, a permis d'observer qu'une diffusion volumique importante avait lieu en presence de vegetation senescente qui se tenait debout et pour les champs non laboures. La diffusion de surface dominait cependant pour les champs avec de faibles quantites de residus et des residus plus fins. La recherche a toutefois demontre que des conditions de surface complexes etaient crees par differentes combinaisons de residus et de pratiques de labourage. Par consequent, il faudra attendre que des donnees multi-polarisees ou polarimetriques soient acquises par les capteurs prevus a bord du satellite canadien RADARSAT-2 et du satellite ENVISAT de l'Agence spatiale europeenne avant de pouvoir completement caracteriser les champs apres la recolte.
The desA and desB genes from Clostridium scindens ATCC 35704 encode steroid-17,20-desmolase.
Devendran, Saravanan; Mythen, Sean M; Ridlon, Jason M
2018-06-01
Clostridium scindens is a gut microbe capable of removing the side-chain of cortisol, forming 11β-hydro-xyandrostenedione. A cortisol-inducible operon ( desABCD ) was previously identified in C. scindens ATCC 35704 by RNA-Seq. The desC gene was shown to encode a cortisol 20α-hydroxysteroid dehydrogenase (20α-HSDH). The desD encodes a protein annotated as a member of the major facilitator family, predicted to function as a cortisol transporter. The desA and desB genes are annotated as N-terminal and C-terminal transketolases, respectively. We hypothesized that the DesAB forms a complex and has steroid-17,20-desmolase activity. We cloned the desA and desB genes from C. scindens ATCC 35704 in pETDuet for overexpression in Escherichia coli The purified recombinant DesAB was determined to be a 142 ± 5.4 kDa heterotetramer. We developed an enzyme-linked continuous spectrophotometric assay to quantify steroid-17,20-desmolase. This was achieved by coupling DesAB-dependent formation of 11β-hydroxyandrostenedione with the NADPH-dependent reduction of the steroid 17-keto group by a recombinant 17β-HSDH from the filamentous fungus, Cochliobolus lunatus The pH optimum for the coupled assay was 7.0 and kinetic constants using cortisol as substrate were K m of 4.96 ± 0.57 µM and k cat of 0.87 ± 0.076 min -1 Substrate-specificity studies revealed that rDesAB recognized substrates regardless of 11β-hydroxylation, but had an absolute requirement for 17,21-dihydroxy 20-ketosteroids. Copyright © 2018 Devendran et al.
Exemples d’utilisation des techniques d’optimisation en calcul de structures de reacteurs
2003-03-01
34~ optimisation g~om~trique (architecture fig~e) A la difference du secteur automobile et des avionneurs, la plupart des composants des r~acteurs n...utilise des lois de comportement mat~riaux non lin~aires ainsi que des hypotheses de grands d~placements. Ltude d’optimisation consiste ý minimiser...un disque simple et d~cid6 de s~lectionner trois param~tes qui influent sur la rupture : 1paisseur de la toile du disque ElI, la hauteur L3 et la
[Outstanding problems of normal and pathological morphology of the diffuse endocrine system].
Iaglov, V V; Iaglova, N V
2011-01-01
The diffuse endocrine system (DES)--a mosaic-cellular endoepithelial gland--is the biggest part of the human endocrine system. Scientists used to consider cells of DES as neuroectodermal. According to modem data cells of DES are different cytogenetic types because they develop from the different embryonic blastophyllum. So that any hormone-active tumors originated from DES of the digestive, respiratory and urogenital system shouldn't be considered as neuroendocrinal tumors. The basic problems of DES morphology and pathology are the creation of scientifically substantiated histogenetic classification of DES tumors.
Rodenas, C; Lucas, X; Tarantini, T; Del Olmo, D; Roca, J; Vazquez, J M; Martinez, E A; Parrilla, I
2014-02-01
The aim of this study was to evaluate the influence of Hoechst 33342 (H-42) concentration and of the male donor on the efficiency of sex-sorting procedure in canine spermatozoa. Semen samples from six dogs (three ejaculates/dog) were diluted to 100 × 10(6) sperm/ml, split into four aliquots, stained with increasing H-42 concentrations (5, 7.5, 10 and 12.5 μl, respectively) and sorted by flow cytometry. The rates of non-viable (FDA+), oriented (OS) and selected spermatozoa (SS), as well as the average sorting rates (SR, sorted spermatozoa/s), were used to determine the sorting efficiency. The effects of the sorting procedure on the quality of sorted spermatozoa were evaluated in terms of total motility (TM), percentage of viable spermatozoa (spermatozoa with membrane and acrosomal integrity) and percentage of spermatozoa with reacted/damaged acrosomes. X- and Y-chromosome-bearing sperm populations were identified in all of the samples stained with 7.5, 10 and 12.5 μl of H-42, while these two populations were only identified in 77.5% of samples stained with 5 μl. The values of OS, SS and SR were influenced by the male donor (p < 0.01) but not by the H-42 concentration used. The quality of sorted sperm samples immediately after sorting was similar to that of fresh samples, while centrifugation resulted in significant reduction (p < 0.05) in TM and in the percentage of viable spermatozoa and a significant increase (p < 0.01) in the percentage of spermatozoa with damage/reacted acrosomes. In conclusion, the sex-sorting of canine spermatozoa by flow cytometry can be performed successfully using H-42 concentrations between 7.5 and 12.5 μl. The efficiency of the sorting procedure varies based on the dog from which the sperm sample derives. © 2013 Blackwell Verlag GmbH.
Fong, Jeremy; Khan, Aliya
2012-01-01
Résumé Objectif Présenter aux médecins de famille une approche fondée sur des données probantes pour le diagnostic et la prise en charge de l’hypocalcémie. Qualité des données On a fait une recherche documentaire dans MEDLINE et EMBASE pour cerner des articles parus de 2000 à 2010 portant sur le diagnostic et la prise en charge de l’hypocalcémie. Les niveaux des données (de I à III) sont indiqués, le cas échéant et, dans la plupart des études, les données se situent aux niveaux II et III. On a aussi examiné les références des ouvrages appropriés pour trouver des articles pertinents. Message principal L’hypocalcémie est habituellement attribuable à des taux insuffisants d’hormones parathyroïdes ou de vitamine D ou à une résistance à ces hormones. Le traitement consiste surtout à administrer des suppléments de calcium et de vitamine D par voie orale, ainsi que de magnésium s’il y a carence. On peut intensifier davantage le traitement avec des diurétiques thiazidiques, des chélateurs de phosphore et un régime à faible teneur en sel et en phosphore quand on traite une hypocalcémie secondaire à une hypoparathyroïdie. Une carence en calcium aiguë et dangereuse pour la vie exige un traitement au moyen de calcium intraveineux. Les recommandations thérapeutiques actuelles se fondent largement sur l’opinion d’experts cliniciens et de rapports de cas publiés, car il n’y a pas suffisamment de données probantes disponibles tirées d’études cliniques contrôlées. Au nombre des complications des thérapies actuelles, on peut mentionner l’hypercalciurie, la néphrocalcinose, l’insuffisance rénale et la calcification des tissus mous. La thérapie actuelle est limitée par les fluctuations du calcium sérique. Quoique ces complications soient bien reconnues, les effets sur le bien-être général, l’humeur, la fonction cognitive et la qualité de vie, ainsi que les risques de complications, n’ont pas été adéquatement étudiés. Conclusion Les médecins de famille jouent un rôle central dans l’éducation des patients à propos de la prise en charge à long terme et des complications de l’hypocalcémie. À l’heure actuelle, la prise en charge est sous-optimale et marquée par des fluctuations dans le calcium sérique et l’absence d’une thérapie de remplacement des hormones parathyroïdes homologuée pour l’hypoparathyroïdie.
NASA Astrophysics Data System (ADS)
Dolez, Patricia
Le travail de recherche effectue dans le cadre de ce projet de doctorat a permis la mise au point d'une methode de mesure des pertes ac destinee a l'etude des supraconducteurs a haute temperature critique. Pour le choix des principes de cette methode, nous nous sommes inspires de travaux anterieurs realises sur les supraconducteurs conventionnels, afin de proposer une alternative a la technique electrique, presentant lors du debut de cette these des problemes lies a la variation du resultat des mesures selon la position des contacts de tension sur la surface de l'echantillon, et de pouvoir mesurer les pertes ac dans des conditions simulant la realite des futures applications industrielles des rubans supraconducteurs: en particulier, cette methode utilise la technique calorimetrique, associee a une calibration simultanee et in situ. La validite de la methode a ete verifiee de maniere theorique et experimentale: d'une part, des mesures ont ete realisees sur des echantillons de Bi-2223 recouverts d'argent ou d'alliage d'argent-or et comparees avec les predictions theoriques donnees par Norris, nous indiquant la nature majoritairement hysteretique des pertes ac dans nos echantillons; d'autre part, une mesure electrique a ete realisee in situ dont les resultats correspondent parfaitement a ceux donnes par notre methode calorimetrique. Par ailleurs, nous avons compare la dependance en courant et en frequence des pertes ac d'un echantillon avant et apres qu'il ait ete endommage. Ces mesures semblent indiquer une relation entre la valeur du coefficient de la loi de puissance modelisant la dependance des pertes avec le courant, et les inhomogeneites longitudinales du courant critique induites par l'endommagement. De plus, la variation en frequence montre qu'au niveau des grosses fractures transverses creees par l'endommagement dans le coeur supraconducteur, le courant se partage localement de maniere a peu pres equivalente entre les quelques grains de matiere supraconductrice qui restent fixes a l'interface coeur-enveloppe, et le revetement en alliage d'argent. L'interet d'une methode calorimetrique par rapport a la technique electrique, plus rapide, plus sensible et maintenant fiable, reside dans la possibilite de realiser des mesures de pertes ac dans des environnements complexes, reproduisant la situation presente par exemple dans un cable de transport d'energie ou dans un transformateur. En particulier, la superposition d'un courant dc en plus du courant ac habituel nous a permis d'observer experimentalement, pour la premiere fois a notre connaissance, un comportement particulier des pertes ac en fonction de la valeur du courant dc decrit theoriquement par LeBlanc. Nous avons pu en deduire la presence d'un courant d'ecrantage Meissner de 16 A, ce qui nous permet de determiner les conditions dans lesquelles une reduction du niveau de pertes ac pourrait etre obtenue par application d'un courant dc, phenomene denomme "vallee de Clem".
Ngomba, Armelle Viviane; Kollo, Basile; Bita, André Fouda; Djouma, Fabrice Nembot; Edengue, Jean Marie; Elongue, Marie Josée; Adiogo, Dieudonné
2016-01-01
Introduction Les métropoles camerounaises concentrent un nombre croissant d'enfants cibles, non atteints par les services de vaccination de routine. Méthodes Une étude transversale descriptive, basée sur échantillonnage exhaustif des formations sanitaires légales offrant en routine des services de vaccination a été réalisée dans le district de santé de Djoungolo, (ville de Yaoundé). L'évaluation de l'offre des services de vaccination a été calquée sur l'approche « Atteindre Chaque District ». Résultats Des 70 formations sanitaires ayant participé à l'étude, 3 (4,3%) disposaient d'un micro plan actualisé pour la vaccination de routine. Des 63 (89,4%) formations sanitaires possédant un réfrigérateur fonctionnel, 12 (19,0%) vaccinaient au quotidien en stratégie fixe. Cinquante-sept (81,0%) formations sanitaires ne conduisaient pas des sessions de vaccination en stratégies avancées. La participation des membres de la communauté aux activités de vaccination de routine étaient effective dans 1 aire de santé sur les 12 que compte le district. Une courbe de suivi des couvertures vaccinales correctement renseignée étaient disponible dans 6 (8,5%) formations sanitaires. Conclusion L'approche « Atteindre Chaque District » telle que mise en œuvre dans le district de santé de Djoungolo limite l'atteinte d'un maximum d'enfants cibles. L'effectivité d'une micro planification réaliste, la régularité des sessions de vaccination en stratégie fixes et avancées, le suivi des données orienté vers l'action, la redynamisation communautaire en faveur de la vaccination sont des voies d'amélioration des prestations des services de vaccination, dans ce district. PMID:28292168
Cancer du sein au Maroc: profil phénotypique des tumeurs
Khalil, Ahmadaye Ibrahim; Bendahhou, Karima; Mestaghanmi, Houriya; Saile, Rachid; Benider, Abdellatif
2016-01-01
Le cancer du sein est le plus fréquent chez la femme et figure parmi les principales causes de mortalité liées au cancer. La curabilité de ce type tumoral est en augmentation, grâce aux programmes de dépistage et aux progrès thérapeutiques, qui ont certes augmenté la survie des patients. Mais des défis restent à relever en rapport avec l’instabilité phénotypique des cellules cancéreuses. L’objectif de ce travail est d’étudier le profil phénotypique du cancer du sein chez les patients pris en charge au Centre Mohammed VI pour le traitement des Cancers, durant les années 2013-2014. Il s’agit d’une étude transversale sur deux années, incluant les cas du cancer du sein pris en charge au Centre. Le recueil des données était fait à partir des dossiers des patients et analysés par le logiciel Epi Info. 1277 patients ont été pris en charge au sein de notre centre. 99,5% des cas de sexe féminin, l’âge moyen était 50,20 ± 11,34 ans. Le type histologique le plus fréquent était le carcinome canalaire infiltrant (80,7% des cas). Le stade diagnostic était précoce (56,9%). Le phénotype moléculaire le plus fréquent était le luminal A (41,4% des cas). Le luminal B, le HER2 et les triples négatifs étaient dans respectivement 10,4%, 6,3%, 11,2% des cas. L’étude du phénotype tumoral des patients atteints du cancer du sein permet l’orientation du clinicien dans le choix du traitement, et des décideurs dans la planification de programmes de lutte contre cette pathologie. PMID:28292037
NASA Astrophysics Data System (ADS)
Varlet, Madeleine
Le recours aux modeles et a la modelisation est mentionne dans la documentation scientifique comme un moyen de favoriser la mise en oeuvre de pratiques d'enseignement-apprentissage constructivistes pour pallier les difficultes d'apprentissage en sciences. L'etude prealable du rapport des enseignantes et des enseignants aux modeles et a la modelisation est alors pertinente pour comprendre leurs pratiques d'enseignement et identifier des elements dont la prise en compte dans les formations initiale et disciplinaire peut contribuer au developpement d'un enseignement constructiviste des sciences. Plusieurs recherches ont porte sur ces conceptions sans faire de distinction selon les matieres enseignees, telles la physique, la chimie ou la biologie, alors que les modeles ne sont pas forcement utilises ou compris de la meme maniere dans ces differentes disciplines. Notre recherche s'est interessee aux conceptions d'enseignantes et d'enseignants de biologie au secondaire au sujet des modeles scientifiques, de quelques formes de representations de ces modeles ainsi que de leurs modes d'utilisation en classe. Les resultats, que nous avons obtenus au moyen d'une serie d'entrevues semi-dirigees, indiquent que globalement leurs conceptions au sujet des modeles sont compatibles avec celle scientifiquement admise, mais varient quant aux formes de representations des modeles. L'examen de ces conceptions temoigne d'une connaissance limitee des modeles et variable selon la matiere enseignee. Le niveau d'etudes, la formation prealable, l'experience en enseignement et un possible cloisonnement des matieres pourraient expliquer les differentes conceptions identifiees. En outre, des difficultes temporelles, conceptuelles et techniques peuvent freiner leurs tentatives de modelisation avec les eleves. Toutefois, nos resultats accreditent l'hypothese que les conceptions des enseignantes et des enseignants eux-memes au sujet des modeles, de leurs formes de representation et de leur approche constructiviste en enseignement representent les plus grands obstacles a la construction des modeles en classe. Mots-cles : Modeles et modelisation, biologie, conceptions, modes d'utilisation, constructivisme, enseignement, secondaire.
Facteurs de risque cardiovasculaires au cours du lupus systémique
Harzallah, Amel; Hajji, Mariem; Kaaroud, Hayet; Hamida, Fethi Ben; Abdallah, Taieb Ben
2015-01-01
Cette étude a pour objectif d’évaluer la fréquence des facteurs de risque cardiovasculaires au cours du lupus et de préciser leur prévalence. Etude rétrospective portant sur 250 patients ayant un lupus, diagnostiqué selon les critères de l'ACR, hospitalisés entre 1970 et 2013. Les données cliniques et para cliniques ont été recueillies à partir des observations médicales. Il s'agit de 228 femmes et 22 hommes d’âge moyen au diagnostic du lupus de 30, 32 ans (extrêmes: 16-69). La durée moyenne du suivi des patients était de 64 mois (extrêmes: 7 jours- 382mois). Quatre vingt dix patients (36%) étaient hypertendus, 74% avaient une hypercholestérolémie et 22% étaient diabétiques. Pour les autres facteurs de risque cardiovasculaire traditionnels, un âge > 50 ans a été retrouvé dans 40% des cas, le sexe masculin dans 8% des cas, l'obésité dans 76% des cas et le tabagisme dans 11% des cas. Les facteurs de risque surajoutés sont représentés par la présence des anticorps antiphospholipides (47% des cas), la néphropathie lupique (49% des cas), l'insuffisance rénale (42% des cas), la corticothérapie au long cours (74% des cas) et la chronicité de la maladie dans 35% des cas. Les complications cardiovasculaires retrouvées dans notre série étaient: les accidents vasculaires cérébraux (2%) et l'insuffisance coronarienne (5,6%). Devant l'importance du risque cardiovasculaire au cours du lupus, une surveillance rapprochée des facteurs de risque cardio-vasculaires semble primordiale chez les lupiques. PMID:27022427
Teng, Monica; Zhao, Ying Jiao; Khoo, Ai Leng; Ananthakrishna, Rajiv; Yeo, Tiong Cheng; Lim, Boon Peng; Chan, Mark Y; Loh, Joshua P
2018-06-05
Compared with second-generation durable polymer drug-eluting stents (DP-DES), the cost-effectiveness of biodegradable polymer drug-eluting stents (BP-DES) remains unclear in the real-world setting. We assessed the cost-effectiveness of BP-DES in patients with coronary artery disease undergoing percutaneous coronary intervention (PCI). We developed a decision-analytic model to compare the cost-effectiveness of BP-DES to DP-DES over one year and five years from healthcare payer perspective. Relative treatment effects during the first year post-PCI were obtained from a real-world population analysis while clinical event risks in the subsequent four years were derived from a meta-analysis of published studies. At one year, based on the clinical data analysis of 497 propensity-score matched pairs of patients, BP-DES were associated with an incremental cost-effectiveness ratio (ICER) of USD20,503 per quality-adjusted life-year (QALY) gained. At five years, BP-DES yielded an ICER of USD4,062 per QALY gained. At the willingness-to-pay threshold of USD50,400 (one gross domestic product per capita in Singapore in 2015), BP-DES were cost-effective. Sensitivity analysis showed that the cost of stents had a significant impact on the cost-effectiveness of BP-DES. Threshold analysis demonstrated that if the cost difference between BP-DES and DP-DES exceeded USD493, BP-DES would not be cost-effective in patients with one-year of follow-up. BP-DES were cost-effective compared with DP-DES in patients with coronary artery disease at one year and five years after PCI. It is worth noting that the cost of stents had a significant impact on the findings. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
NASA Astrophysics Data System (ADS)
Aliouane, T.; Bouzid, D.; Belkhir, N.; Bouzid, S.; Herold, V.
2005-05-01
La fabrication des composants en verre optique nécessite des moyens de grande précision dans les procédés de finition vue l'importance accordée à leur qualité. Durant le processus de polissage des verres optiques, le polissoir est un élément clé et a un impact direct sur les performances des composants optiques, non seulement il est utilisé comme support de grains abrasifs mais il doit posséder la fonction de transmission de la pression aux grains. La connaissance de ses propriétés, essentiellement mécanique, est impérative afin d'obtenir un état de surface optimal des composants optiques destinés à remplir des fonctions très précises dans des appareils optiques très performants. Dans cette étude, nous avons constaté que les propriétés des polissoirs en polyuréthanne tel que la dureté, le module d'élasticité et la densité varient au cours du polissage. Ce changement a des effets sur l'état de surface de verre optique, causé par le changement microstructural de la surface du polissoir (distribution et dimensions des pores) et par conséquent sur la quantité des abrasifs (en oxyde de cérium) insérée dans les pores, ce qui influe sur la quantité de verre enlevée et sur l'état de surface du composant. Sur la base des résultats obtenus, il a été prouvé que le polissoir subit des modifications très importantes ce qui influe considérablement sur son efficacité de polissage.
Bromer, Jason G.; Wu, Jie; Zhou, Yuping; Taylor, Hugh S.
2009-01-01
Diethylstilbestrol (DES) is a nonsteroidal estrogen that induces developmental anomalies of the female reproductive tract. The homeobox gene HOXA10 controls uterine organogenesis, and its expression is altered after in utero DES exposure. We hypothesized that an epigenetic mechanism underlies DES-mediated alterations in HOXA10 expression. We analyzed the expression pattern and methylation profile of HOXA10 after DES exposure. Expression of HOXA10 is increased in human endometrial cells after DES exposure, whereas Hoxa10 expression is repressed and shifted caudally from its normal location in mice exposed in utero. Cytosine guanine dinucleotide methylation frequency in the Hoxa10 intron was higher in DES-exposed offspring compared with controls (P = 0.017). The methylation level of Hoxa10 was also higher in the caudal portion of the uterus after DES exposure at the promoter and intron (P < 0.01). These changes were accompanied by increased expression of DNA methyltransferases 1 and 3b. No changes in methylation were observed after in vitro or adult DES exposure. DES has a dual mechanism of action as an endocrine disruptor; DES functions as a classical estrogen and directly stimulates HOXA10 expression with short-term exposure, however, in utero exposure results in hypermethylation of the HOXA10 gene and long-term altered HOXA10 expression. We identify hypermethylation as a novel mechanism of DES-induced altered developmental programming. PMID:19299448
VizieR Online Data Catalog: Australian Dark Energy Survey (OzDES) quasar catalog (Tie+, 2017)
NASA Astrophysics Data System (ADS)
Tie, S. S.; Martini, P.; Mudd, D.; Ostrovski, F.; Reed, S. L.; Lidman, C.; Kochanek, C.; Davis, T. M.; Sharp, R.; Uddin, S.; King, A.; Wester, W.; Tucker, B. E.; Tucker, D. L.; Buckley-Geer, E.; Carollo, D.; Childress, M.; Glazebrook, K.; Hinton, S. R.; Lewis, G.; Macaulay, E.; O'Neill, C. R.; Abbott, T. M. C.; Abdalla, F. B.; Annis, J.; Benoit-Levy, A.; Bertin, E.; Brooks, D.; Carnero Rosell, A.; Carrasco Kind, M.; Carretero, J.; Cunha, C. E.; da Costa, L. N.; Depoy, D. L.; Desai, S.; Doel, P.; Eifler, T. F.; Evrard, A. E.; Finley, D. A.; Flaugher, B.; Fosalba, P.; Frieman, J.; Garcia-Bellido, J.; Gaztanaga, E.; Gerdes, D. W.; Goldstein, D. A.; Gruen, D.; Gruendl, R. A.; Gutierrez, G.; Honscheid, K.; James, D. J.; Kuehn, K.; Kuropatkin, N.; Lima, M.; Maia, M. A. G.; Marshall, J. L.; Menanteau, F.; Miller, C. J.; Miquel, R.; Nichol, R. C.; Nord, B.; Ogando, R.; Plazas, A. A.; Romer, A. K.; Sanchez, E.; Santiago, B.; Scarpine, V.; Schubnell, M.; Sevilla-Noarbe, I.; Smith, R. C.; Soares-Santos, M.; Sobreira, F.; Suchyta, E.; Swanson, M. E. C.; Tarle, G.; Thomas, D.; Walker, A. R.; DES Collaboration
2017-07-01
The Australian Dark Energy Survey (OzDES; Yuan et al. 2015MNRAS.452.3047Y) is a spectroscopic survey of the DES supernova fields using the AAOmega spectrograph (Smith et al. 2004SPIE.5492..410S) on the Anglo-Australian Telescope (AAT). The field of view of the AAT multi-object fiber-positioning system (Lewis et al. 2002MNRAS.333..279L) is well matched to DECam, making the AAT a well-suited spectroscopic follow-up instrument for DES. OzDES commenced observations at the same time as DES in 2013B and aims to measure redshifts for thousands of host galaxies of Type Ia supernovae and black hole masses for hundreds of AGNs and quasars (King et al. 2015MNRAS.453.1701K) using reverberation mapping (Blandford & McKee 1982ApJ...255..419B; Peterson 1993PASP..105..247P). The observing targets and results of OzDES observations are compiled into a spectroscopic catalog known as the Global Redshift Catalog (GRC). The GRC is updated after every OzDES observing season. In this work, we used the 2016 February version of the OzDES GRC. Here we present the OzDES Quasar Catalog of 1263 OzDES sources with Mi<-22 mag and i<22 mag that are spectroscopically confirmed quasars. (1 data file).
Les Brulures Electriques par Haut Voltage - A Propos de 10 Cas
Belmir, R.; Fejjal, N.; El Omari, M.; El Mazouz, S.; Gharib, N.; Abassi, A.; Belmahi, A.
2008-01-01
Summary Les accidents électriques par haute tension (AEHT) provoquent des brûlures profondes par effet Joule le long des axes vasculo-nerveux entre les points d'entrée et de sortie, qui sont le siège de lésions délabrantes. Les Auteurs rapportent une série de dix cas d'AEHT admis au service de chirurgie réparatrice et de brûlés de l'Hôpital Ibn Sina de Rabat à travers laquelle ils étudient les caractéristiques épidémiologiques, cliniques et thérapeutiques. Tous les patients étaient des adultes de sexe masculin dont l'âge moyen était de 31 ans. Dans 70% des cas, ces brûlures étaient secondaires à un contact avec les distributeurs d'électricité avec une surface brûlée inférieure à 20%. Le traitement des lésions électrothermiques a nécessité des interventions itératives avec amputation des segments de membres nécrosés dans 70% des cas, dont les suites étaient marquées par des séquelles fonctionnelles invalidantes. La prévention des AEHT, en particulier pour les accidents du travail au sein des professions exposées, reste fondamentale. PMID:21991124
Detection de la fin de la compaction des anodes par le son
NASA Astrophysics Data System (ADS)
Sanogo, Bazoumana
L'objectif de ce projet etait de developper un outil de controle en temps reel du temps de compaction en se servant du son genere par le vibrocompacteur pendant le formage des anodes crues. Ainsi, une application a ete developpee pour l'analyse des sons enregistres. Des essais ont ete realises avec differents microphones pour une meilleure qualite des mesures et un a ete choisi pour la suite du projet. De meme, differents tests ont ete realises sur des anodes de laboratoire ainsi que des anodes a l'echelle industrielle afin de mettre en place une methode pour la detection du temps optimal necessaire au formage des anodes. Les travaux au laboratoire de carbone a l'Universite du Quebec a Chicoutimi (UQAC) ont consiste a l'enregistrement de son des anodes fabriquees sur place avec differentes configurations; et a la caracterisation de certaines anodes de l'usine. Les anodes fabriquees au laboratoire sont reparties en deux groupes. Le premier regroupe les anodes pour la validation de notre methode. Ce sont des anodes produites avec des temps de compaction differents. Le laboratoire de carbone a l'UQAC est unique et il est possible de produire des anodes avec les memes proprietes que celles des anodes industrielles. Par consequent, la validation initialement prevue a l'usine a ete effectuee avec les anodes de laboratoire. Le deuxieme groupe a servi a etudier les effets des matieres premieres sur le temps de compaction. Le type de coke et le type de brai ont constitue les differentes variations dans ce deuxieme groupe. Quant aux tests et mesures a l'usine, ils ont ete realises en trois campagnes de mesure. La premiere campagne en juin 2014 a servi a standardiser et a trouver le meilleur positionnement des appareils pour les mesures, a regler le logiciel et a faire les premieres mesures. Une deuxieme campagne en mai 2015 a fait l'objet d'enregistrement de son en classant les anodes selon differents temps de compaction. La troisieme et derniere campagne en decembre 2015 a ete le lieu de tests finaux a l'usine en fabriquant des anodes avec differents criteres (variation du temps de compaction, taux de brai, arret manuel du compacteur, variation de la pression des ballons du haut du compacteur). Ces anodes ont ete ensuite analysees au laboratoire a l'UQAC. En parallele a ces travaux precites, l'amelioration de l'application d'analyse du son a ete faite avec le choix des parametres d'analyse et leur standardisation. Les resultats des premiers tests au laboratoire et ceux de la campagne de juin 2014 ont montre que la formation des anodes se fait suivant trois etapes : rearrangement des particules et du brai, compaction et consolidation et enfin la finition. Ces travaux ont montre en outre que le temps de compaction joue un role tres important dans la definition des proprietes finales des anodes. Ainsi, en plus du type de brai, du taux de brai et du type de coke, il faut tenir compte du temps de sur-compaction et de sous-compaction. En effet, ceci a ete demontre a travers les deux validations qui ont ete realisees. Les resultats de la caracterisation des echantillons (venant des anodes de la campagne de decembre 2015) ont montre qu'une anode compactee a un temps optimal acquiert une bonne resistance a la compression et sa resistivite electrique baisse. En outre, on note que le temps de compaction dans notre cas a baisse legerement avec l'augmentation de la pression des ballons de haut du vibrocompacteur. Ce qui a eu pour effet d'augmenter la densite crue de l'anode. Toutefois, il faut s'abstenir de generaliser ce constat car le nombre d'anodes testees est faible dans notre cas. Par ailleurs, cette etude montre que le temps necessaire pour le formage d'une anode croit avec l'augmentation du taux de brai et baisse legerement avec l'augmentation de la pression des ballons. (Abstract shortened by ProQuest.).
Stent Polymers: Do They Make a Difference?
Rizas, Konstantinos D; Mehilli, Julinda
2016-06-01
The necessity of polymers on drug-eluting stent (DES) platforms is dictated by the need of an adequate amount and optimal release kinetic of the antiproliferative drugs for achieving ideal DES performance. However, the chronic vessel wall inflammation related to permanent polymer persistence after the drug has been eluted might trigger late restenosis and stent thrombosis. Biodegradable polymers have the potential to avoid these adverse events. A variety of biodegradable polymer DES platforms have been clinically tested, showing equal outcomes with the standard-bearer permanent polymer DES within the first year of implantation. At longer-term follow-up, promising lower rates of stent thrombosis have been observed with the early generation biodegradable polymer DES platforms compared to first-generation DES. Whether this safety benefit still persists with newer biodegradable polymer DES generations against second-generation permanent polymer DES needs to be explored. © 2016 American Heart Association, Inc.
The Dark Energy Survey Image Processing Pipeline
NASA Astrophysics Data System (ADS)
Morganson, E.; Gruendl, R. A.; Menanteau, F.; Carrasco Kind, M.; Chen, Y.-C.; Daues, G.; Drlica-Wagner, A.; Friedel, D. N.; Gower, M.; Johnson, M. W. G.; Johnson, M. D.; Kessler, R.; Paz-Chinchón, F.; Petravick, D.; Pond, C.; Yanny, B.; Allam, S.; Armstrong, R.; Barkhouse, W.; Bechtol, K.; Benoit-Lévy, A.; Bernstein, G. M.; Bertin, E.; Buckley-Geer, E.; Covarrubias, R.; Desai, S.; Diehl, H. T.; Goldstein, D. A.; Gruen, D.; Li, T. S.; Lin, H.; Marriner, J.; Mohr, J. J.; Neilsen, E.; Ngeow, C.-C.; Paech, K.; Rykoff, E. S.; Sako, M.; Sevilla-Noarbe, I.; Sheldon, E.; Sobreira, F.; Tucker, D. L.; Wester, W.; DES Collaboration
2018-07-01
The Dark Energy Survey (DES) is a five-year optical imaging campaign with the goal of understanding the origin of cosmic acceleration. DES performs a ∼5000 deg2 survey of the southern sky in five optical bands (g, r, i, z, Y) to a depth of ∼24th magnitude. Contemporaneously, DES performs a deep, time-domain survey in four optical bands (g, r, i, z) over ∼27 deg2. DES exposures are processed nightly with an evolving data reduction pipeline and evaluated for image quality to determine if they need to be retaken. Difference imaging and transient source detection are also performed in the time domain component nightly. On a bi-annual basis, DES exposures are reprocessed with a refined pipeline and coadded to maximize imaging depth. Here we describe the DES image processing pipeline in support of DES science, as a reference for users of archival DES data, and as a guide for future astronomical surveys.
Mamoudou, Savadogo; Lassina, Dao; Fla, Koueta
2015-01-01
Nous rapportons deux cas d'infection à Pseudomonas aeruginosa: un cas de méningite et un cas d'infection urinaire. Les auteurs rappellent qu’à côté des étiologies classiques des méningites et des infections urinaires, des germes résistants comme Pseudomonas aeruginosa peuvent être responsables d'infections à localisation méningées et urinaires et dont il faut connaître pour une bonne prise en charge. Le traitement de ces infections requiert un antibiogramme au regard de la grande capacité de résistance de Pseudomonas aeruginosa en milieu hospitalier. La limitation des gestes invasifs et l'application rigoureuse des mesures de prévention des infections en milieu hospitalier contribueront à lutter efficacement contre ces infections en milieu de soins. PMID:26491521
2003-03-01
combat modernes et des avions d’affaires E. Garrigues, Th. Percheron DASSAULT AVIATION DGT/DTA/IAP F-922 14, Saint-Cloud Cedex France 1. Introduction ...de vol, des acedidrations rigides et des rdponses de la structure ( jauges et acedidrations). Struturl Premdicton Grdjustments n~~~ligh Testsn~n Fig4ure
Through the Regional Applied Research Effort (RARE) program, the Chemical Exposure Research Branch and Region 9 personnel in San Francisco, California are collaborating on a project to explore sample pretreatment and preconcentration techniques to lower the method detection limit...
The perspectives, information and conclusions conveyed in research project abstracts, progress reports, final reports, journal abstracts and journal publications convey the viewpoints of the principal investigator and may not represent the views and policies of ORD and EPA. Concl...
The perspectives, information and conclusions conveyed in research project abstracts, progress reports, final reports, journal abstracts and journal publications convey the viewpoints of the principal investigator and may not represent the views and policies of ORD and EPA. Concl...
USDA-ARS?s Scientific Manuscript database
This work describes the development and validation of a method for the simultaneous determination of 13 estrogens and progestogens in honey by high performance liquid chromatography-tandem mass spectrometry. The target compounds were preconcentrated by solid phase extraction. Pretreatment variables ...
2013-02-11
calibration curves was ±5%. Ion chromatography (IC) was used for analysis of perchlorate and other ionic targets. Analysis was carried out on a...The methods utilize liquid or gas chromatography , techniques that do not lend themselves well to portable devices and methods. Portable methods are...
A STRINGENT COMPARISON OF SAMPLING AND ANALYSIS METHODS FOR VOCS IN AMBIENT AIR
A carefully designed study was conducted during the summer of 1998 to simultaneously collect samples of ambient air by canisters and compare the analysis results to direct sorbent preconcentration results taken at the time of sample collection. A total of 32 1-h sample sets we...
Determination of Trace Level Triclosan in Water by Online Preconcentration and HPLC-UV Diode Array
An online high performance liquid chromatography (HPLC) method for the detection and quantification of trace levels of triclosan in water is discussed. Triclosan, an anti-bacterial agent, and related compounds have been shown to reach municipal waste waters through the disposal ...