Discovery of Sound in the Sea (DOSITS) Website Development
2013-03-04
life affect ocean sound levels? • Science of Sound > Sounds in the Sea > How will ocean acidification affect ocean sound levels? • Science of Sound...Science of Sound > Sounds in the Sea > How does shipping affect ocean sound levels? • Science of Sound > Sounds in the Sea > How does marine
Neonatal incubators: a toxic sound environment for the preterm infant?*.
Marik, Paul E; Fuller, Christopher; Levitov, Alexander; Moll, Elizabeth
2012-11-01
High sound pressure levels may be harmful to the maturing newborn. Current guidelines suggest that the sound pressure levels within a neonatal intensive care unit should not exceed 45 dB(A). It is likely that environmental noise as well as the noise generated by the incubator fan and respiratory equipment may contribute to the total sound pressure levels. Knowledge of the contribution of each component and source is important to develop effective strategies to reduce noise within the incubator. The objectives of this study were to determine the sound levels, sound spectra, and major sources of sound within a modern neonatal incubator (Giraffe Omnibed; GE Healthcare, Helsinki, Finland) using a sound simulation study to replicate the conditions of a preterm infant undergoing high-frequency jet ventilation (Life Pulse, Bunnell, UT). Using advanced sound data acquisition and signal processing equipment, we measured and analyzed the sound level at a dummy infant's ear and at the head level outside the enclosure. The sound data time histories were digitally acquired and processed using a digital Fast Fourier Transform algorithm to provide spectra of the sound and cumulative sound pressure levels (dBA). The simulation was done with the incubator cooling fan and ventilator switched on or off. In addition, tests were carried out with the enclosure sides closed and hood down and then with the enclosure sides open and the hood up to determine the importance of interior incubator reverberance on the interior sound levels With all the equipment off and the hood down, the sound pressure levels were 53 dB(A) inside the incubator. The sound pressure levels increased to 68 dB(A) with all equipment switched on (approximately 10 times louder than recommended). The sound intensity was 6.0 × 10(-8) watts/m(2); this sound level is roughly comparable with that generated by a kitchen exhaust fan on high. Turning the ventilator off reduced the overall sound pressure levels to 64 dB(A) and the sound pressure levels in the low-frequency band of 0 to 100 Hz were reduced by 10 dB(A). The incubator fan generated tones at 200, 400, and 600 Hz that raised the sound level by approximately 2 dB(A)-3 dB(A). Opening the enclosure (with all equipment turned on) reduced the sound levels above 50 Hz by reducing the revereberance within the enclosure. The sound levels, especially at low frequencies, within a modern incubator may reach levels that are likely to be harmful to the developing newborn. Much of the noise is at low frequencies and thus difficult to reduce by conventional means. Therefore, advanced forms of noise control are needed to address this issue.
Disher, Timothy C; Benoit, Britney; Inglis, Darlene; Burgess, Stacy A; Ellsmere, Barbara; Hewitt, Brenda E; Bishop, Tanya M; Sheppard, Christopher L; Jangaard, Krista A; Morrison, Gavin C; Campbell-Yeo, Marsha L
To identify baseline sound levels, patterns of sound levels, and potential barriers and facilitators to sound level reduction. The study setting was neonatal and pediatric intensive care units in a tertiary care hospital. Participants were staff in both units and parents of currently hospitalized children or infants. One 24-hour sound measurements and one 4-hour sound measurement linked to observed sound events were conducted in each area of the center's neonatal intensive care unit. Two of each measurement type were conducted in the pediatric intensive care unit. Focus groups were conducted with parents and staff. Transcripts were analyzed with descriptive content analysis and themes were compared against results from quantitative measurements. Sound levels exceeded recommended standards at nearly every time point. The most common code was related to talking. Themes from focus groups included the critical care context and sound levels, effects of sound levels, and reducing sound levels-the way forward. Results are consistent with work conducted in other critical care environments. Staff and families realize that high sound levels can be a problem, but feel that the culture and context are not supportive of a quiet care space. High levels of ambient sound suggest that the largest changes in sound levels are likely to come from design and equipment purchase decisions. L10 and Lmax appear to be the best outcomes for measurement of behavioral interventions.
Code of Federal Regulations, 2011 CFR
2011-10-01
... second or less. Decibel (dB) means a unit of measurement of sound pressure levels. dB(A) means the sound... operate similar equipment under similar conditions. Sound level or Sound pressure level means ten times... an eight-hour time-weighted-average sound level (TWA) of 85 dB(A), or, equivalently, a dose of 50...
Excessive exposure of sick neonates to sound during transport
Buckland, L; Austin, N; Jackson, A; Inder, T
2003-01-01
Objective: To determine the levels of sound to which infants are exposed during routine transport by ambulance, aircraft, and helicopter. Design: Sound levels during 38 consecutive journeys from a regional level III neonatal intensive care unit were recorded using a calibrated data logging sound meter (Quest 2900). The meter was set to record "A" weighted slow response integrated sound levels, which emulates the response of the human ear, and "C" weighted response sound levels as a measure of total sound level exposure for all frequencies. The information was downloaded to a computer using MS HyperTerminal. The resulting data were stored, and a graphical profile was generated for each journey using SigmaPlot software. Setting: Eight journeys involved ambulance transport on country roads, 24 involved fixed wing aircraft, and four were by helicopter. Main outcome measures: Relations between decibel levels and events or changes in transport mode were established by correlating the time logged on the sound meter with the standard transport documentation sheet. Results: The highest sound levels were recorded during air transport. However, mean sound levels for all modes of transport exceeded the recommended levels for neonatal intensive care. The maximum sound levels recorded were extremely high at greater than 80 dB in the "A" weighted hearing range and greater than 120 dB in the total frequency range. Conclusions: This study raises major concerns about the excessive exposure of the sick newborn to sound during transportation. PMID:14602701
Sound level exposure of high-risk infants in different environmental conditions.
Byers, Jacqueline F; Waugh, W Randolph; Lowman, Linda B
2006-01-01
To provide descriptive information about the sound levels to which high-risk infants are exposed in various actual environmental conditions in the NICU, including the impact of physical renovation on sound levels, and to assess the contributions of various types of equipment, alarms, and activities to sound levels in simulated conditions in the NICU. Descriptive and comparative design. Convenience sample of 134 infants at a southeastern quarternary children's hospital. A-weighted decibel (dBA) sound levels under various actual and simulated environmental conditions. The renovated NICU was, on average, 4-6 dBA quieter across all environmental conditions than a comparable nonrenovated room, representing a significant sound level reduction. Sound levels remained above consensus recommendations despite physical redesign and staff training. Respiratory therapy equipment, alarms, staff talking, and infant fussiness contributed to higher sound levels. Evidence-based sound-reducing strategies are proposed. Findings were used to plan environment management as part of a developmental, family-centered care, performance improvement program and in new NICU planning.
Salomons, Erik M.; Lohman, Walter J. A.; Zhou, Han
2016-01-01
Propagation of sound waves in air can be considered as a special case of fluid dynamics. Consequently, the lattice Boltzmann method (LBM) for fluid flow can be used for simulating sound propagation. In this article application of the LBM to sound propagation is illustrated for various cases: free-field propagation, propagation over porous and non-porous ground, propagation over a noise barrier, and propagation in an atmosphere with wind. LBM results are compared with solutions of the equations of acoustics. It is found that the LBM works well for sound waves, but dissipation of sound waves with the LBM is generally much larger than real dissipation of sound waves in air. To circumvent this problem it is proposed here to use the LBM for assessing the excess sound level, i.e. the difference between the sound level and the free-field sound level. The effect of dissipation on the excess sound level is much smaller than the effect on the sound level, so the LBM can be used to estimate the excess sound level for a non-dissipative atmosphere, which is a useful quantity in atmospheric acoustics. To reduce dissipation in an LBM simulation two approaches are considered: i) reduction of the kinematic viscosity and ii) reduction of the lattice spacing. PMID:26789631
Salomons, Erik M; Lohman, Walter J A; Zhou, Han
2016-01-01
Propagation of sound waves in air can be considered as a special case of fluid dynamics. Consequently, the lattice Boltzmann method (LBM) for fluid flow can be used for simulating sound propagation. In this article application of the LBM to sound propagation is illustrated for various cases: free-field propagation, propagation over porous and non-porous ground, propagation over a noise barrier, and propagation in an atmosphere with wind. LBM results are compared with solutions of the equations of acoustics. It is found that the LBM works well for sound waves, but dissipation of sound waves with the LBM is generally much larger than real dissipation of sound waves in air. To circumvent this problem it is proposed here to use the LBM for assessing the excess sound level, i.e. the difference between the sound level and the free-field sound level. The effect of dissipation on the excess sound level is much smaller than the effect on the sound level, so the LBM can be used to estimate the excess sound level for a non-dissipative atmosphere, which is a useful quantity in atmospheric acoustics. To reduce dissipation in an LBM simulation two approaches are considered: i) reduction of the kinematic viscosity and ii) reduction of the lattice spacing.
L-type calcium channels refine the neural population code of sound level
Grimsley, Calum Alex; Green, David Brian
2016-01-01
The coding of sound level by ensembles of neurons improves the accuracy with which listeners identify how loud a sound is. In the auditory system, the rate at which neurons fire in response to changes in sound level is shaped by local networks. Voltage-gated conductances alter local output by regulating neuronal firing, but their role in modulating responses to sound level is unclear. We tested the effects of L-type calcium channels (CaL: CaV1.1–1.4) on sound-level coding in the central nucleus of the inferior colliculus (ICC) in the auditory midbrain. We characterized the contribution of CaL to the total calcium current in brain slices and then examined its effects on rate-level functions (RLFs) in vivo using single-unit recordings in awake mice. CaL is a high-threshold current and comprises ∼50% of the total calcium current in ICC neurons. In vivo, CaL activates at sound levels that evoke high firing rates. In RLFs that increase monotonically with sound level, CaL boosts spike rates at high sound levels and increases the maximum firing rate achieved. In different populations of RLFs that change nonmonotonically with sound level, CaL either suppresses or enhances firing at sound levels that evoke maximum firing. CaL multiplies the gain of monotonic RLFs with dynamic range and divides the gain of nonmonotonic RLFs with the width of the RLF. These results suggest that a single broad class of calcium channels activates enhancing and suppressing local circuits to regulate the sensitivity of neuronal populations to sound level. PMID:27605536
Noise in a Laboratory Animal Facility from the Human and Mouse Perspectives
Reynolds, Randall P; Kinard, Will L; Degraff, Jesse J; Leverage, Ned; Norton, John N
2010-01-01
The current study was performed to understand the level of sound produced by ventilated racks, animal transfer stations, and construction equipment that mice in ventilated cages hear relative to what humans would hear in the same environment. Although the ventilated rack and animal transfer station both produced sound pressure levels above the ambient level within the human hearing range, the sound pressure levels within the mouse hearing range did not increase above ambient noise from either noise source. When various types of construction equipment were used 3 ft from the ventilated rack, the sound pressure level within the mouse hearing range was increased but to a lesser degree for each implement than were the sound pressure levels within the human hearing range. At more distant locations within the animal facility, sound pressure levels from the large jackhammer within the mouse hearing range decreased much more rapidly than did those in the human hearing range, indicating that less of the sound is perceived by mice than by humans. The relatively high proportion of low-frequency sound produced by the shot blaster, used without the metal shot that it normally uses to clean concrete, increased the sound pressure level above the ambient level for humans but did not increase sound pressure levels above ambient noise for mice at locations greater than 3 ft from inside of the cage, where sound was measured. This study demonstrates that sound clearly audible to humans in the animal facility may be perceived to a lesser degree or not at all by mice, because of the frequency content of the sound. PMID:20858361
Assessment of sound levels in a neonatal intensive care unit in tabriz, iran.
Valizadeh, Sousan; Bagher Hosseini, Mohammad; Alavi, Nasrinsadat; Asadollahi, Malihe; Kashefimehr, Siamak
2013-03-01
High levels of sound have several negative effects, such as noise-induced hearing loss and delayed growth and development, on premature infants in neonatal intensive care units (NICUs). In order to reduce sound levels, they should first be measured. This study was performed to assess sound levels and determine sources of noise in the NICU of Alzahra Teaching Hospital (Tabriz, Iran). In a descriptive study, 24 hours in 4 workdays were randomly selected. Equivalent continuous sound level (Leq), sound level that is exceeded only 10% of the time (L10), maximum sound level (Lmax), and peak instantaneous sound pressure level (Lzpeak) were measured by CEL-440 sound level meter (SLM) at 6 fixed locations in the NICU. Data was collected using a questionnaire. SPSS13 was then used for data analysis. Mean values of Leq, L10, and Lmax were determined as 63.46 dBA, 65.81 dBA, and 71.30 dBA, respectively. They were all higher than standard levels (Leq < 45 dB, L10 ≤50 dB, and Lmax ≤65 dB). The highest Leq was measured at the time of nurse rounds. Leq was directly correlated with the number of staff members present in the ward. Finally, sources of noise were ordered based on their intensity. Considering that sound levels were higher than standard levels in our studied NICU, it is necessary to adopt policies to reduce sound.
Assessment of Sound Levels in a Neonatal Intensive Care Unit in Tabriz, Iran
Valizadeh, Sousan; Bagher Hosseini, Mohammad; Alavi, Nasrinsadat; Asadollahi, Malihe; Kashefimehr, Siamak
2013-01-01
Introduction: High levels of sound have several negative effects, such as noise-induced hearing loss and delayed growth and development, on premature infants in neonatal intensive care units (NICUs). In order to reduce sound levels, they should first be measured. This study was performed to assess sound levels and determine sources of noise in the NICU of Alzahra Teaching Hospital (Tabriz, Iran). Methods: In a descriptive study, 24 hours in 4 workdays were randomly selected. Equivalent continuous sound level (Leq), sound level that is exceeded only 10% of the time (L10), maximum sound level (Lmax), and peak instantaneous sound pressure level (Lzpeak) were measured by CEL-440 sound level meter (SLM) at 6 fixed locations in the NICU. Data was collected using a questionnaire. SPSS13 was then used for data analysis. Results: Mean values of Leq, L10, and Lmax were determined as 63.46 dBA, 65.81 dBA, and 71.30 dBA, respectively. They were all higher than standard levels (Leq < 45 dB, L10 ≤50 dB, and Lmax ≤65 dB). The highest Leq was measured at the time of nurse rounds. Leq was directly correlated with the number of staff members present in the ward. Finally, sources of noise were ordered based on their intensity. Conclusion: Considering that sound levels were higher than standard levels in our studied NICU, it is necessary to adopt policies to reduce sound. PMID:25276706
Laboratory studies of scales for measuring helicopter noise
NASA Technical Reports Server (NTRS)
Ollerhead, J. B.
1982-01-01
The adequacy of the effective perceived noise level (EPNL) procedure for rating helicopter noise annoyance was investigated. Recordings of 89 helicopters and 30 fixed wing aircraft (CTOL) flyover sounds were rated with respect to annoyance by groups of approximately 40 subjects. The average annoyance scores were transformed to annoyance levels defined as the equally annoying sound levels of a fixed reference sound. The sound levels of the test sounds were measured on various scales, with and without corrections for duration, tones, and impulsiveness. On average, the helicopter sounds were judged equally annoying to CTOL sounds when their duration corrected levels are approximately 2 dB higher. Multiple regression analysis indicated that, provided the helicopter/CTOL difference of about 2 dB is taken into account, the particular linear combination of level, duration, and tone corrections inherent in EPNL is close to optimum. The results reveal no general requirement for special EPNL correction terms to penalize helicopter sounds which are particularly impulsive; impulsiveness causes spectral and temporal changes which themselves adequately amplify conventionally measured sound levels.
Ruhland, Janet L.; Yin, Tom C. T.; Tollin, Daniel J.
2013-01-01
Sound localization accuracy in elevation can be affected by sound spectrum alteration. Correspondingly, any stimulus manipulation that causes a change in the peripheral representation of the spectrum may degrade localization ability in elevation. The present study examined the influence of sound duration and level on localization performance in cats with the head unrestrained. Two cats were trained using operant conditioning to indicate the apparent location of a sound via gaze shift, which was measured with a search-coil technique. Overall, neither sound level nor duration had a notable effect on localization accuracy in azimuth, except at near-threshold levels. In contrast, localization accuracy in elevation improved as sound duration increased, and sound level also had a large effect on localization in elevation. For short-duration noise, the performance peaked at intermediate levels and deteriorated at low and high levels; for long-duration noise, this “negative level effect” at high levels was not observed. Simulations based on an auditory nerve model were used to explain the above observations and to test several hypotheses. Our results indicated that neither the flatness of sound spectrum (before the sound reaches the inner ear) nor the peripheral adaptation influences spectral coding at the periphery for localization in elevation, whereas neural computation that relies on “multiple looks” of the spectral analysis is critical in explaining the effect of sound duration, but not level. The release of negative level effect observed for long-duration sound could not be explained at the periphery and, therefore, is likely a result of processing at higher centers. PMID:23657278
Vermeulen, L; Van de Perre, V; Permentier, L; De Bie, S; Verbeke, G; Geers, R
2016-06-01
This study investigates the relationship between sound levels, pre-slaughter handling during loading and pork quality. Pre-slaughter variables were investigated from loading till slaughter. A total of 3213 pigs were measured 30 min post-mortem for pH(30LT) (M. Longissimus thoracis). First, a sound level model for the risk to develop PSE meat was established. The difference in maximum and mean sound level during loading, mean sound level during lairage and mean sound level prior to stunning remained significant within the model. This indicated that sound levels during loading had a significant added value to former sound models. Moreover, this study completed the global classification checklist (Vermeulen et al., 2015a) by developing a linear mixed model for pH(30LT) and PSE prevalence, with the difference in maximum and mean sound level measured during loading, the feed withdrawal period and the difference in temperature during loading and lairage. Hence, this study provided new insights over previous research where loading procedures were not included. Copyright © 2016 Elsevier Ltd. All rights reserved.
L-type calcium channels refine the neural population code of sound level.
Grimsley, Calum Alex; Green, David Brian; Sivaramakrishnan, Shobhana
2016-12-01
The coding of sound level by ensembles of neurons improves the accuracy with which listeners identify how loud a sound is. In the auditory system, the rate at which neurons fire in response to changes in sound level is shaped by local networks. Voltage-gated conductances alter local output by regulating neuronal firing, but their role in modulating responses to sound level is unclear. We tested the effects of L-type calcium channels (Ca L : Ca V 1.1-1.4) on sound-level coding in the central nucleus of the inferior colliculus (ICC) in the auditory midbrain. We characterized the contribution of Ca L to the total calcium current in brain slices and then examined its effects on rate-level functions (RLFs) in vivo using single-unit recordings in awake mice. Ca L is a high-threshold current and comprises ∼50% of the total calcium current in ICC neurons. In vivo, Ca L activates at sound levels that evoke high firing rates. In RLFs that increase monotonically with sound level, Ca L boosts spike rates at high sound levels and increases the maximum firing rate achieved. In different populations of RLFs that change nonmonotonically with sound level, Ca L either suppresses or enhances firing at sound levels that evoke maximum firing. Ca L multiplies the gain of monotonic RLFs with dynamic range and divides the gain of nonmonotonic RLFs with the width of the RLF. These results suggest that a single broad class of calcium channels activates enhancing and suppressing local circuits to regulate the sensitivity of neuronal populations to sound level. Copyright © 2016 the American Physiological Society.
Scattering of sound by atmospheric turbulence predictions in a refractive shadow zone
NASA Technical Reports Server (NTRS)
Mcbride, Walton E.; Bass, Henry E.; Raspet, Richard; Gilbert, Kenneth E.
1990-01-01
According to ray theory, regions exist in an upward refracting atmosphere where no sound should be present. Experiments show, however, that appreciable sound levels penetrate these so-called shadow zones. Two mechanisms contribute to sound in the shadow zone: diffraction and turbulent scattering of sound. Diffractive effects can be pronounced at lower frequencies but are small at high frequencies. In the short wavelength limit, then, scattering due to turbulence should be the predominant mechanism involved in producing the sound levels measured in shadow zones. No existing analytical method includes turbulence effects in the prediction of sound pressure levels in upward refractive shadow zones. In order to obtain quantitative average sound pressure level predictions, a numerical simulation of the effect of atmospheric turbulence on sound propagation is performed. The simulation is based on scattering from randomly distributed scattering centers ('turbules'). Sound pressure levels are computed for many realizations of a turbulent atmosphere. Predictions from the numerical simulation are compared with existing theories and experimental data.
Prediction of light aircraft interior sound pressure level using the room equation
NASA Technical Reports Server (NTRS)
Atwal, M.; Bernhard, R.
1984-01-01
The room equation is investigated for predicting interior sound level. The method makes use of an acoustic power balance, by equating net power flow into the cabin volume to power dissipated within the cabin using the room equation. The sound power level transmitted through the panels was calculated by multiplying the measured space averaged transmitted intensity for each panel by its surface area. The sound pressure level was obtained by summing the mean square sound pressures radiated from each panel. The data obtained supported the room equation model in predicting the cabin interior sound pressure level.
Jeanson, Lena; Wiegrebe, Lutz; Gürkov, Robert; Krause, Eike; Drexl, Markus
2017-02-01
The presentation of intense, low-frequency (LF) sound to the human ear can cause very slow, sinusoidal oscillations of cochlear sensitivity after LF sound offset, coined the "Bounce" phenomenon. Changes in level and frequency of spontaneous otoacoustic emissions (SOAEs) are a sensitive measure of the Bounce. Here, we investigated the effect of LF sound level and frequency on the Bounce. Specifically, the level of SOAEs was tracked for minutes before and after a 90-s LF sound exposure. Trials were carried out with several LF sound levels (93 to 108 dB SPL corresponding to 47 to 75 phons at a fixed frequency of 30 Hz) and different LF sound frequencies (30, 60, 120, 240 and 480 Hz at a fixed loudness level of 80 phons). At an LF sound frequency of 30 Hz, a minimal sound level of 102 dB SPL (64 phons) was sufficient to elicit a significant Bounce. In some subjects, however, 93 dB SPL (47 phons), the lowest level used, was sufficient to elicit the Bounce phenomenon and actual thresholds could have been even lower. Measurements with different LF sound frequencies showed a mild reduction of the Bounce phenomenon with increasing LF sound frequency. This indicates that the strength of the Bounce not only is a simple function of the spectral separation between SOAE and LF sound frequency but also depends on absolute LF sound frequency, possibly related to the magnitude of the AC component of the outer hair cell receptor potential.
Guo, Bin; Huang, Jing; Guo, Xin-biao
2015-06-18
To evaluate the preventive effects of sound insulation windows on traffic noise. Indoor noise levels of the residential rooms (on both the North 4th ring road side and the campus side) with closed sound insulation windows were measured using the sound level meter, and comparisons with the simultaneously measured outdoor noise levels were made. In addition, differences of indoor noise levels between rooms with closed sound insulation windows and open sound insulation windows were also compared. The average outdoor noise levels of the North 4th ring road was higher than 70 dB(A), which exceeded the limitation stated in the "Environmental Quality Standard for Noise" (GB 3096-2008) in our country. However, with the sound insulation windows closed, the indoor noise levels reduced significantly to the level under 35 dB(A) (P<0.05), which complied with the indoor noise level standards in our country. The closed or open states of the sound insulation windows had significant influence on the indoor noise levels (P<0.05). Compared with the open state of the sound insulation window, when the sound insulation windows were closed, the indoor noise levels reduced 18.8 dB(A) and 8.3 dB(A) in residential rooms facing North 4th ring road side and campus side, respectively. The results indicated that installation of insulation windows had significant noise reduction effects on street residential buildings especially on the rooms facing major traffic roads. Installation of the sound insulation windows has significant preventive effects on indoor noise in the street residential building.
24 CFR 51.106 - Implementation.
Code of Federal Regulations, 2010 CFR
2010-04-01
... day-night average sound level data are not available may be evaluated from NEF or CNEL analyses using.... The day-night average sound level may be estimated from the design hour L10 or Leq values by the.... The Department of Defense uses day-night average sound level based on C-weighted sound level...
Durai, Mithila; Searchfield, Grant D
2017-01-01
Objectives: A randomized cross-over trial in 18 participants tested the hypothesis that nature sounds, with unpredictable temporal characteristics and high valence would yield greater improvement in tinnitus than constant, emotionally neutral broadband noise. Study Design: The primary outcome measure was the Tinnitus Functional Index (TFI). Secondary measures were: loudness and annoyance ratings, loudness level matches, minimum masking levels, positive and negative emotionality, attention reaction and discrimination time, anxiety, depression and stress. Each sound was administered using MP3 players with earbuds for 8 continuous weeks, with a 3 week wash-out period before crossing over to the other treatment sound. Measurements were undertaken for each arm at sound fitting, 4 and 8 weeks after administration. Qualitative interviews were conducted at each of these appointments. Results: From a baseline TFI score of 41.3, sound therapy resulted in TFI scores at 8 weeks of 35.6; broadband noise resulted in significantly greater reduction (8.2 points) after 8 weeks of sound therapy use than nature sounds (3.2 points). The positive effect of sound on tinnitus was supported by secondary outcome measures of tinnitus, emotion, attention, and psychological state, but not interviews. Tinnitus loudness level match was higher for BBN at 8 weeks; while there was little change in loudness level matches for nature sounds. There was no change in minimum masking levels following sound therapy administration. Self-reported preference for one sound over another did not correlate with changes in tinnitus. Conclusions: Modeled under an adaptation level theory framework of tinnitus perception, the results indicate that the introduction of broadband noise shifts internal adaptation level weighting away from the tinnitus signal, reducing tinnitus magnitude. Nature sounds may modify the affective components of tinnitus via a secondary, residual pathway, but this appears to be less important for sound effectiveness. The different rates of adaptation to broadband noise and nature sound by the auditory system may explain the different tinnitus loudness level matches. In addition to group effects there also appears to be a great deal of individual variation. A sound therapy framework based on adaptation level theory is proposed that accounts for individual variation in preference and response to sound. Clinical Trial Registration: www.anzctr.org.au, identifier #12616000742471.
Durai, Mithila; Searchfield, Grant D.
2017-01-01
Objectives: A randomized cross-over trial in 18 participants tested the hypothesis that nature sounds, with unpredictable temporal characteristics and high valence would yield greater improvement in tinnitus than constant, emotionally neutral broadband noise. Study Design: The primary outcome measure was the Tinnitus Functional Index (TFI). Secondary measures were: loudness and annoyance ratings, loudness level matches, minimum masking levels, positive and negative emotionality, attention reaction and discrimination time, anxiety, depression and stress. Each sound was administered using MP3 players with earbuds for 8 continuous weeks, with a 3 week wash-out period before crossing over to the other treatment sound. Measurements were undertaken for each arm at sound fitting, 4 and 8 weeks after administration. Qualitative interviews were conducted at each of these appointments. Results: From a baseline TFI score of 41.3, sound therapy resulted in TFI scores at 8 weeks of 35.6; broadband noise resulted in significantly greater reduction (8.2 points) after 8 weeks of sound therapy use than nature sounds (3.2 points). The positive effect of sound on tinnitus was supported by secondary outcome measures of tinnitus, emotion, attention, and psychological state, but not interviews. Tinnitus loudness level match was higher for BBN at 8 weeks; while there was little change in loudness level matches for nature sounds. There was no change in minimum masking levels following sound therapy administration. Self-reported preference for one sound over another did not correlate with changes in tinnitus. Conclusions: Modeled under an adaptation level theory framework of tinnitus perception, the results indicate that the introduction of broadband noise shifts internal adaptation level weighting away from the tinnitus signal, reducing tinnitus magnitude. Nature sounds may modify the affective components of tinnitus via a secondary, residual pathway, but this appears to be less important for sound effectiveness. The different rates of adaptation to broadband noise and nature sound by the auditory system may explain the different tinnitus loudness level matches. In addition to group effects there also appears to be a great deal of individual variation. A sound therapy framework based on adaptation level theory is proposed that accounts for individual variation in preference and response to sound. Clinical Trial Registration: www.anzctr.org.au, identifier #12616000742471. PMID:28337139
40 CFR 201.22 - Measurement instrumentation.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Criteria § 201.22 Measurement instrumentation. (a) A sound level meter or alternate sound level measurement...., 1430 Broadway, New York, NY 10018. Table 1—Sound Level Corrections When Using a Type 2 (or S2A... the sound level meter or (2) the manufacturer of the microphone. The choice of both devices must be...
40 CFR 201.22 - Measurement instrumentation.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Criteria § 201.22 Measurement instrumentation. (a) A sound level meter or alternate sound level measurement...., 1430 Broadway, New York, NY 10018. Table 1—Sound Level Corrections When Using a Type 2 (or S2A... the sound level meter or (2) the manufacturer of the microphone. The choice of both devices must be...
Prospective cohort study on noise levels in a pediatric cardiac intensive care unit.
Garcia Guerra, Gonzalo; Joffe, Ari R; Sheppard, Cathy; Pugh, Jodie; Moez, Elham Khodayari; Dinu, Irina A; Jou, Hsing; Hartling, Lisa; Vohra, Sunita
2018-04-01
To describe noise levels in a pediatric cardiac intensive care unit, and to determine the relationship between sound levels and patient sedation requirements. Prospective observational study at a pediatric cardiac intensive care unit (PCICU). Sound levels were measured continuously in slow A weighted decibels dB(A) with a sound level meter SoundEarPro® during a 4-week period. Sedation requirement was assessed using the number of intermittent (PRNs) doses given per hour. Analysis was conducted with autoregressive moving average models and the Granger test for causality. 39 children were included in the study. The average (SD) sound level in the open area was 59.4 (2.5) dB(A) with a statistically significant but clinically unimportant difference between day/night hours (60.1 vs. 58.6; p-value < 0.001). There was no significant difference between sound levels in the open area/single room (59.4 vs. 60.8, p-value = 0.108). Peak noise levels were > 90 dB. There was a significant association between average (p-value = 0.030) and peak sound levels (p-value = 0.006), and number of sedation PRNs. Sound levels were above the recommended values with no differences between day/night or open area/single room. High sound levels were significantly associated with sedation requirements. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Huang, Xianfeng; Meng, Yao; Huang, Riming
2017-10-01
This paper describes a theoretical method for predicting the improvement of the impact sound insulation to a floating floor with the resilient interlayer. Statistical energy analysis (SEA) model, which is skilful in calculating the floor impact sound, is set up for calculating the reduction in impact sound pressure level in downstairs room. The sound transmission paths which include direct path and flanking paths are analyzed to find the dominant one; the factors that affect impact sound reduction for a floating floor are explored. Then, the impact sound level in downstairs room is determined and comparisons between predicted and measured data are conducted. It is indicated that for the impact sound transmission across a floating floor, the flanking path impact sound level contribute tiny influence on overall sound level in downstairs room, and a floating floor with low stiffness interlayer exhibits favorable sound insulation on direct path. The SEA approach applies to the floating floors with resilient interlayers, which are experimentally verified, provides a guidance in sound insulation design.
Sound levels and their effects on children in a German primary school.
Eysel-Gosepath, Katrin; Daut, Tobias; Pinger, Andreas; Lehmacher, Walter; Erren, Thomas
2012-12-01
Considerable sound levels are produced in primary schools by voices of children and resonance effects. As a consequence, hearing loss and mental impairment may occur. In a Cologne primary school, sound levels were measured in three different classrooms, each with 24 children, 8-10 years old, and one teacher. Sound dosimeters were positioned in the room and near the teacher's ear. Additional measurements were done in one classroom fully equipped with sound-absorbing materials. A questionnaire containing 12 questions about noise at school was distributed to 100 children, 8-10 years old. Measurements were repeated after children had been taught about noise damage and while "noise lights" were used. Mean sound levels of 5-h per day measuring period were 78 dB (A) near the teacher's ear and 70 dB (A) in the room. The average of all measured maximal sound levels for 1 s was 105 dB (A) for teachers, and 100 dB (A) for rooms. In the soundproofed classroom, Leq was 66 dB (A). The questionnaire revealed certain judgment of the children concerning situations with high sound levels and their ability to develop ideas for noise reduction. However, no clear sound level reduction was identified after noise education and using "noise lights" during lessons. Children and their teachers are equally exposed to high sound levels at school. Early sensitization to noise and the possible installation of sound-absorbing materials can be important means to prevent noise-associated hearing loss and mental impairment.
NASA Technical Reports Server (NTRS)
Atwal, Mahabir S.; Heitman, Karen E.; Crocker, Malcolm J.
1986-01-01
The validity of the room equation of Crocker and Price (1982) for predicting the cabin interior sound pressure level was experimentally tested using a specially constructed setup for simultaneous measurements of transmitted sound intensity and interior sound pressure levels. Using measured values of the reverberation time and transmitted intensities, the equation was used to predict the space-averaged interior sound pressure level for three different fuselage conditions. The general agreement between the room equation and experimental test data is considered good enough for this equation to be used for preliminary design studies.
Evaluation of the impact of noise metrics on tiltrotor aircraft design
NASA Technical Reports Server (NTRS)
Sternfeld, H.; Spencer, R.; Ziegenbein, P.
1995-01-01
A subjective noise evaluation was conducted in which the test participants evaluated the annoyance of simulated sounds representative of future civil tiltrotor aircraft. The subjective responses were correlated with the noise metrics of A-weighted sound pressure level, overall sound pressure level, and perceived level. The results indicated that correlation between subjective response and A-weighted sound pressure level is considerably enhanced by combining it in a multiple regression with overall sound pressure level. As a single metric, perceived level correlated better than A-weighted sound pressure level due to greater emphasis on low frequency noise components. This latter finding was especially true for indoor noise where the mid and high frequency noise components are attenuated by typical building structure. Using the results of the subjective noise evaluation, the impact on tiltrotor aircraft design was also evaluated. While A-weighted sound pressure level can be reduced by reduction in tip speed, an increase in number of rotor blades is required to achieve significant reduction of low frequency noise as measured by overall sound pressure level. Additional research, however, is required to achieve comparable reductions in impulsive noise due to blade-vortex interaction, and also to achieve reduction in broad band noise.
49 CFR 325.37 - Location and operation of sound level measurement system; highway operations.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 5 2011-10-01 2011-10-01 false Location and operation of sound level measurement...; Highway Operations § 325.37 Location and operation of sound level measurement system; highway operations. (a) The microphone of a sound level measurement system that conforms to the rules in § 325.23 of this...
49 CFR 325.71 - Scope of the rules in this subpart.
Code of Federal Regulations, 2010 CFR
2010-10-01
... the sound level generated by a motor vehicle, as displayed on a sound level measurement system, during the measurement of the motor vehicle's sound level emissions at a test site which is not a standard site. (b) The purpose of adding or subtracting a correction factor is to equate the sound level reading...
49 CFR 325.71 - Scope of the rules in this subpart.
Code of Federal Regulations, 2011 CFR
2011-10-01
... the sound level generated by a motor vehicle, as displayed on a sound level measurement system, during the measurement of the motor vehicle's sound level emissions at a test site which is not a standard site. (b) The purpose of adding or subtracting a correction factor is to equate the sound level reading...
24 CFR Appendix I to Subpart B of... - Definition of Acoustical Quantities
Code of Federal Regulations, 2011 CFR
2011-04-01
... National Standard Specification for Type 1 Sound Level Meters S1.4-1971. Fast time-averaging and A...), somewhat as is the ear. With fast time averaging the sound level meter responds particularly to recent... (iii) The maximum sound level obtained with fast averaging time of a sound level meter exceeds the...
24 CFR Appendix I to Subpart B of... - Definition of Acoustical Quantities
Code of Federal Regulations, 2014 CFR
2014-04-01
... National Standard Specification for Type 1 Sound Level Meters S1.4-1971. Fast time-averaging and A...), somewhat as is the ear. With fast time averaging the sound level meter responds particularly to recent... (iii) The maximum sound level obtained with fast averaging time of a sound level meter exceeds the...
24 CFR Appendix I to Subpart B of... - Definition of Acoustical Quantities
Code of Federal Regulations, 2012 CFR
2012-04-01
... National Standard Specification for Type 1 Sound Level Meters S1.4-1971. Fast time-averaging and A...), somewhat as is the ear. With fast time averaging the sound level meter responds particularly to recent... (iii) The maximum sound level obtained with fast averaging time of a sound level meter exceeds the...
24 CFR Appendix I to Subpart B of... - Definition of Acoustical Quantities
Code of Federal Regulations, 2013 CFR
2013-04-01
... National Standard Specification for Type 1 Sound Level Meters S1.4-1971. Fast time-averaging and A...), somewhat as is the ear. With fast time averaging the sound level meter responds particularly to recent... (iii) The maximum sound level obtained with fast averaging time of a sound level meter exceeds the...
A national project to evaluate and reduce high sound pressure levels from music.
Ryberg, Johanna Bengtsson
2009-01-01
The highest recommended sound pressure levels for leisure sounds (music) in Sweden are 100 dB LAeq and 115 dB LAFmax for adults, and 97 dB LAeq and 110 dB LAFmax where children under the age of 13 have access. For arrangements intended for children, levels should be consistently less than 90 dB LAeq. In 2005, a national project was carried out with the aim of improving environments with high sound pressure levels from music, such as concert halls, restaurants, and cinemas. The project covered both live and recorded music. Of Sweden's 290 municipalities, 134 took part in the project, and 93 of these carried out sound measurements. Four hundred and seventy one establishments were investigated, 24% of which exceeded the highest recommended sound pressure levels for leisure sounds in Sweden. Of festival and concert events, 42% exceeded the recommended levels. Those who visit music events/establishments thus run a relatively high risk of exposure to harmful sound levels. Continued supervision in this field is therefore crucial.
Algorithm Development for a Real-Time Military Noise Monitor
2006-03-24
Duration ESLM Enhanced Sound Level Meter ERDC-CERL Engineer Research and Development Center/Construction Engineering Research Laboratory FFT...Fast Fourier Transform FTIG Fort Indiantown Gap Kurt Kurtosis LD Larson Davis Leq Equivalent Sound Level L8eq 8-hr Equivalent...Sound Level Lpk Peak Sound Level m Spectral Slope MCBCL Marine Corps Base Camp Lejeune Neg Number of negative samples NI National
49 CFR 325.57 - Location and operation of sound level measurement systems; stationary test.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 5 2012-10-01 2012-10-01 false Location and operation of sound level measurement...; Stationary Test § 325.57 Location and operation of sound level measurement systems; stationary test. (a) The microphone of a sound level measurement system that conforms to the rules in § 325.23 shall be located at a...
49 CFR 325.57 - Location and operation of sound level measurement systems; stationary test.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 5 2013-10-01 2013-10-01 false Location and operation of sound level measurement...; Stationary Test § 325.57 Location and operation of sound level measurement systems; stationary test. (a) The microphone of a sound level measurement system that conforms to the rules in § 325.23 shall be located at a...
49 CFR 325.23 - Type of measurement systems which may be used.
Code of Federal Regulations, 2011 CFR
2011-10-01
... may be used. The sound level measurement system must meet or exceed the requirements of American National Standard Specification for Sound Level Meters (ANSI S1.4-1971), approved April 27, 1971, issued by..., New York, New York, 10018. (a) A Type 1 sound level meter; (b) A Type 2 sound level meter; or (c) A...
49 CFR 325.57 - Location and operation of sound level measurement systems; stationary test.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 5 2011-10-01 2011-10-01 false Location and operation of sound level measurement...; Stationary Test § 325.57 Location and operation of sound level measurement systems; stationary test. (a) The microphone of a sound level measurement system that conforms to the rules in § 325.23 shall be located at a...
Application of a finite-element model to low-frequency sound insulation in dwellings.
Maluski, S P; Gibbs, B M
2000-10-01
The sound transmission between adjacent rooms has been modeled using a finite-element method. Predicted sound-level difference gave good agreement with experimental data using a full-scale and a quarter-scale model. Results show that the sound insulation characteristics of a party wall at low frequencies strongly depend on the modal characteristics of the sound field of both rooms and of the partition. The effect of three edge conditions of the separating wall on the sound-level difference at low frequencies was examined: simply supported, clamped, and a combination of clamped and simply supported. It is demonstrated that a clamped partition provides greater sound-level difference at low frequencies than a simply supported. It also is confirmed that the sound-pressure level difference is lower in equal room than in unequal room configurations.
Kastelein, Ronald A; van Heerden, Dorianne; Gransier, Robin; Hoek, Lean
2013-12-01
The high under-water sound pressure levels (SPLs) produced during pile driving to build offshore wind turbines may affect harbor porpoises. To estimate the discomfort threshold of pile driving sounds, a porpoise in a quiet pool was exposed to playbacks (46 strikes/min) at five SPLs (6 dB steps: 130-154 dB re 1 μPa). The spectrum of the impulsive sound resembled the spectrum of pile driving sound at tens of kilometers from the pile driving location in shallow water such as that found in the North Sea. The animal's behavior during test and baseline periods was compared. At and above a received broadband SPL of 136 dB re 1 μPa [zero-peak sound pressure level: 151 dB re 1 μPa; t90: 126 ms; sound exposure level of a single strike (SELss): 127 dB re 1 μPa(2) s] the porpoise's respiration rate increased in response to the pile driving sounds. At higher levels, he also jumped out of the water more often. Wild porpoises are expected to move tens of kilometers away from offshore pile driving locations; response distances will vary with context, the sounds' source level, parameters influencing sound propagation, and background noise levels. Copyright © 2013 Elsevier Ltd. All rights reserved.
Knauert, Melissa; Jeon, Sangchoon; Murphy, Terrence E.; Yaggi, H. Klar; Pisani, Margaret A.; Redeker, Nancy S.
2016-01-01
Purpose Sound levels in the intensive care unit (ICU) are universally elevated and are believed to contribute to sleep and circadian disruption. The purpose of this study is to compare overnight ICU sound levels and peak occurrence on A- versus C-weighted scales. Materials and Methods This was a prospective observational study of overnight sound levels in 59 medical ICU patient rooms. Sound level was recorded every 10 seconds on A- and C-weighted decibel scales. Equivalent sound level (Leq) and sound peaks were reported for full and partial night periods. Results The overnight A-weighted Leq of 53.6 dBA was well above World Health Organization (WHO) recommendations; overnight C-weighted Leq was 63.1 dBC (no WHO recommendations). Peak sound occurrence ranged from 1.8 to 23.3 times per hour. Illness severity, mechanical ventilation and delirium were not associated with Leq or peak occurrence. Leq and peak measures for A- and C-weighted decibel scales were significantly different from each other. Conclusions Sound levels in the medical ICU are high throughout the night. Patient factors were not associated with Leq or peak occurrence. Significant discordance between A- and C-weighted values suggests that low frequency sound is a meaningful factor in the medical ICU environment. PMID:27546739
Survey of Occupational Noise Exposure in CF Personnel in Selected High-Risk Trades
2003-11-01
peak, maximum level , minimum level , average sound level , time weighted average, dose, projected 8-hour dose, and upper limit time were measured for...10 4.4.2 Maximum Sound Level ...11 4.4.3 Minimum Sound Level
Noise in neonatal intensive care units (NICUs) and its effect on high risk newborns
NASA Astrophysics Data System (ADS)
Lasky, Robert E.; Williams, Amber L.; van Drongelen, Wim; Gray, Lincoln C.
2005-09-01
We conducted sound surveys in a large state of the art NICU with six separate rooms devoted to the sickest babies requiring the most intensive care (Level III) and six rooms devoted to babies requiring special but less intensive care (Level II). Each room was capable of caring for up to 8 babies. Additionally, there were 8 individual Isolation rooms. We used Larson Davis Spark squflg 703+ dosimeters to record 21 week long sound surveys, seven in each type of room. The American Academy of Pediatrics (1997) has recommended that sound levels in NICUs should never exceed 45 dB(A). That recommendation was exceeded 73.6% of the time in Level II, 92.1% of the time in Isolation, and 96.6% of the time in Level III. Sound levels were lowest in the Level II rooms especially for the softest sounds recorded (L90 and L70). Level III rooms were noisiest except for the noisiest decile of sound (L10). Isolation rooms were noisiest at the highest sound levels (probably because of their reverberant construction materials and enclosed space). Autocorrelation functions were calculated identifying periodic components in all three rooms at about 12 and 24 hrs. Periodic variations were very small compared to random sound variations.
Torija, Antonio J; Ruiz, Diego P; Ramos-Ridao, A F
2013-07-01
A subjective and physical categorization of an ambient sound is the first step to evaluate the soundscape and provides a basis for designing or adapting this ambient sound to match people's expectations. For this reason, the main goal of this work is to develop a categorization and differentiation analysis of soundscapes on the basis of acoustical and perceptual variables. A hierarchical cluster analysis, using 15 semantic-differential attributes and acoustical descriptors to include an equivalent sound-pressure level, maximum-minimum sound-pressure level, impulsiveness of the sound-pressure level, sound-pressure level time course, and spectral composition, was conducted to classify soundscapes into different typologies. This analysis identified 15 different soundscape typologies. Furthermore, based on a discriminant analysis the acoustical descriptors, the crest factor (impulsiveness of the sound-pressure level), and the sound level at 125 Hz were found to be the acoustical variables with the highest impact in the differentiation of the recognized types of soundscapes. Finally, to determine how the different soundscape typologies differed from each other, both subjectively and acoustically, a study was performed.
Common sole larvae survive high levels of pile-driving sound in controlled exposure experiments.
Bolle, Loes J; de Jong, Christ A F; Bierman, Stijn M; van Beek, Pieter J G; van Keeken, Olvin A; Wessels, Peter W; van Damme, Cindy J G; Winter, Hendrik V; de Haan, Dick; Dekeling, René P A
2012-01-01
In view of the rapid extension of offshore wind farms, there is an urgent need to improve our knowledge on possible adverse effects of underwater sound generated by pile-driving. Mortality and injuries have been observed in fish exposed to loud impulse sounds, but knowledge on the sound levels at which (sub-)lethal effects occur is limited for juvenile and adult fish, and virtually non-existent for fish eggs and larvae. A device was developed in which fish larvae can be exposed to underwater sound. It consists of a rigid-walled cylindrical chamber driven by an electro-dynamical sound projector. Samples of up to 100 larvae can be exposed simultaneously to a homogeneously distributed sound pressure and particle velocity field. Recorded pile-driving sounds could be reproduced accurately in the frequency range between 50 and 1000 Hz, at zero to peak pressure levels up to 210 dB re 1µPa(2) (zero to peak pressures up to 32 kPa) and single pulse sound exposure levels up to 186 dB re 1µPa(2)s. The device was used to examine lethal effects of sound exposure in common sole (Solea solea) larvae. Different developmental stages were exposed to various levels and durations of pile-driving sound. The highest cumulative sound exposure level applied was 206 dB re 1µPa(2)s, which corresponds to 100 strikes at a distance of 100 m from a typical North Sea pile-driving site. The results showed no statistically significant differences in mortality between exposure and control groups at sound exposure levels which were well above the US interim criteria for non-auditory tissue damage in fish. Although our findings cannot be extrapolated to fish larvae in general, as interspecific differences in vulnerability to sound exposure may occur, they do indicate that previous assumptions and criteria may need to be revised.
Common Sole Larvae Survive High Levels of Pile-Driving Sound in Controlled Exposure Experiments
Bolle, Loes J.; de Jong, Christ A. F.; Bierman, Stijn M.; van Beek, Pieter J. G.; van Keeken, Olvin A.; Wessels, Peter W.; van Damme, Cindy J. G.; Winter, Hendrik V.; de Haan, Dick; Dekeling, René P. A.
2012-01-01
In view of the rapid extension of offshore wind farms, there is an urgent need to improve our knowledge on possible adverse effects of underwater sound generated by pile-driving. Mortality and injuries have been observed in fish exposed to loud impulse sounds, but knowledge on the sound levels at which (sub-)lethal effects occur is limited for juvenile and adult fish, and virtually non-existent for fish eggs and larvae. A device was developed in which fish larvae can be exposed to underwater sound. It consists of a rigid-walled cylindrical chamber driven by an electro-dynamical sound projector. Samples of up to 100 larvae can be exposed simultaneously to a homogeneously distributed sound pressure and particle velocity field. Recorded pile-driving sounds could be reproduced accurately in the frequency range between 50 and 1000 Hz, at zero to peak pressure levels up to 210 dB re 1µPa2 (zero to peak pressures up to 32 kPa) and single pulse sound exposure levels up to 186 dB re 1µPa2s. The device was used to examine lethal effects of sound exposure in common sole (Solea solea) larvae. Different developmental stages were exposed to various levels and durations of pile-driving sound. The highest cumulative sound exposure level applied was 206 dB re 1µPa2s, which corresponds to 100 strikes at a distance of 100 m from a typical North Sea pile-driving site. The results showed no statistically significant differences in mortality between exposure and control groups at sound exposure levels which were well above the US interim criteria for non-auditory tissue damage in fish. Although our findings cannot be extrapolated to fish larvae in general, as interspecific differences in vulnerability to sound exposure may occur, they do indicate that previous assumptions and criteria may need to be revised. PMID:22431996
NASA Astrophysics Data System (ADS)
Ipatov, M. S.; Ostroumov, M. N.; Sobolev, A. F.
2012-07-01
Experimental results are presented on the effect of both the sound pressure level and the type of spectrum of a sound source on the impedance of an acoustic lining. The spectra under study include those of white noise, a narrow-band signal, and a signal with a preset waveform. It is found that, to obtain reliable data on the impedance of an acoustic lining from the results of interferometric measurements, the total sound pressure level of white noise or the maximal sound pressure level of a pure tone (at every oscillation frequency) needs to be identical to the total sound pressure level of the actual source at the site of acoustic lining on the channel wall.
24 CFR 51.103 - Criteria and standards.
Code of Federal Regulations, 2010 CFR
2010-04-01
... decibels to sound levels in the night from 10 p.m. to 7 a.m. Mathematical expressions for average sound..., as indicated in § 51.106(a)(3). Methods for assessing the contribution of loud impulsive sounds to day-night average sound level at a site and mathematical expressions for determining whether a sound...
Encoding of sound envelope transients in the auditory cortex of juvenile rats and adult rats.
Lu, Qi; Jiang, Cuiping; Zhang, Jiping
2016-02-01
Accurate neural processing of time-varying sound amplitude and spectral information is vital for species-specific communication. During postnatal development, cortical processing of sound frequency undergoes progressive refinement; however, it is not clear whether cortical processing of sound envelope transients also undergoes age-related changes. We determined the dependence of neural response strength and first-spike latency on sound rise-fall time across sound levels in the primary auditory cortex (A1) of juvenile (P20-P30) rats and adult (8-10 weeks) rats. A1 neurons were categorized as "all-pass", "short-pass", or "mixed" ("all-pass" at high sound levels to "short-pass" at lower sound levels) based on the normalized response strength vs. rise-fall time functions across sound levels. The proportions of A1 neurons within each of the three categories in juvenile rats were similar to that in adult rats. In general, with increasing rise-fall time, the average response strength decreased and the average first-spike latency increased in A1 neurons of both groups. At a given sound level and rise-fall time, the average normalized neural response strength did not differ significantly between the two age groups. However, the A1 neurons in juvenile rats showed greater absolute response strength, longer first-spike latency compared to those in adult rats. In addition, at a constant sound level, the average first-spike latency of juvenile A1 neurons was more sensitive to changes in rise-fall time. Our results demonstrate the dependence of the responses of rat A1 neurons on sound rise-fall time, and suggest that the response latency exhibit some age-related changes in cortical representation of sound envelope rise time. Copyright © 2015 Elsevier Ltd. All rights reserved.
The influence of neonatal intensive care unit design on sound level.
Chen, Hsin-Li; Chen, Chao-Huei; Wu, Chih-Chao; Huang, Hsiu-Jung; Wang, Teh-Ming; Hsu, Chia-Chi
2009-12-01
Excessive noise in nurseries has been found to cause adverse effects in infants, especially preterm infants in neonatal intensive care units (NICUs). The NICU design may influence the background sound level. We compared the sound level in two differently designed spaces in one NICU. We hypothesized that the sound level in an enclosed space would be quieter than in an open space. Sound levels were measured continuously 24 hours a day in two separate spaces at the same time, one enclosed and one open. Sound-level meters were placed near beds in each room. Sound levels were expressed as decibels, A-weighted (dBA) and presented as hourly L(eq), L(max), L(10), and L(90). The hourly L(eq) in the open space (50.8-57.2dB) was greater than that of the enclosed space (45.9-51.7dB), with a difference of 0.4-10.4dB, and a mean difference of 4.5dB (p<0.0001). The hourly L(10), L(90), and L(max) in the open space also exceeded that in the enclosed space (p<0.0001). The sound level measured in the enclosed space was quieter than in the open space. The design of bed space should be taken into consideration when building a new NICU. Besides the design of NICU architecture, continuous monitoring of sound level in the NICU is important to maintain a quiet environment.
Harris, Debra D
2015-01-01
Three flooring materials, terrazzo, rubber, and carpet tile, in patient unit corridors were compared for absorption of sound, comfort, light reflectance, employee perceptions and preferences, and patient satisfaction. Environmental stressors, such as noise and ergonomic factors, effect healthcare workers and patients, contributing to increased fatigue, anxiety and stress, decreased productivity, and patient safety and satisfaction. A longitudinal comparative cohort study comparing three types of flooring assessed sound levels, healthcare worker responses, and patient Hospital Consumer Assessment of Healthcare Providers and Systems (HCAHPS) ratings over 42 weeks. A linear mixed model analysis was conducted to determine significant differences between the means for participant responses and objective sound meter data during all three phases of the study. A significant difference was found for sound levels between flooring type for equivalent continuous sound levels. Carpet tile performed better for sound attenuation by absorption, reducing sound levels 3.14 dBA. Preferences for flooring materials changed over the course of the study. The HCAHPS ratings aligned with the sound meter data showing that patients perceived the noise levels to be lower with carpet tiles, improving patient satisfaction ratings. Perceptions for healthcare staff and patients were aligned with the sound meter data. Carpet tile provides sound absorption that affects sound levels and influences occupant's perceptions of environmental factors that contribute to the quality of the indoor environment. Flooring that provides comfort underfoot, easy cleanability, and sound absorption influence healthcare worker job satisfaction and patient satisfaction with their patient experience. © The Author(s) 2015.
Effects of sound level fluctuations on annoyance caused by aircraft-flyover noise
NASA Technical Reports Server (NTRS)
Mccurdy, D. A.
1979-01-01
A laboratory experiment was conducted to determine the effects of variations in the rate and magnitude of sound level fluctuations on the annoyance caused by aircraft-flyover noise. The effects of tonal content, noise duration, and sound pressure level on annoyance were also studied. An aircraft-noise synthesis system was used to synthesize 32 aircraft-flyover noise stimuli representing the factorial combinations of 2 tone conditions, 2 noise durations, 2 sound pressure levels, 2 level fluctuation rates, and 2 level fluctuation magnitudes. Thirty-two test subjects made annoyance judgements on a total of 64 stimuli in a subjective listening test facility simulating an outdoor acoustic environment. Variations in the rate and magnitude of level fluctuations were found to have little, if any, effect on annoyance. Tonal content, noise duration, sound pressure level, and the interaction of tonal content with sound pressure level were found to affect the judged annoyance significantly. The addition of tone corrections and/or duration corrections significantly improved the annoyance prediction ability of noise rating scales.
Decoding sound level in the marmoset primary auditory cortex.
Sun, Wensheng; Marongelli, Ellisha N; Watkins, Paul V; Barbour, Dennis L
2017-10-01
Neurons that respond favorably to a particular sound level have been observed throughout the central auditory system, becoming steadily more common at higher processing areas. One theory about the role of these level-tuned or nonmonotonic neurons is the level-invariant encoding of sounds. To investigate this theory, we simulated various subpopulations of neurons by drawing from real primary auditory cortex (A1) neuron responses and surveyed their performance in forming different sound level representations. Pure nonmonotonic subpopulations did not provide the best level-invariant decoding; instead, mixtures of monotonic and nonmonotonic neurons provided the most accurate decoding. For level-fidelity decoding, the inclusion of nonmonotonic neurons slightly improved or did not change decoding accuracy until they constituted a high proportion. These results indicate that nonmonotonic neurons fill an encoding role complementary to, rather than alternate to, monotonic neurons. NEW & NOTEWORTHY Neurons with nonmonotonic rate-level functions are unique to the central auditory system. These level-tuned neurons have been proposed to account for invariant sound perception across sound levels. Through systematic simulations based on real neuron responses, this study shows that neuron populations perform sound encoding optimally when containing both monotonic and nonmonotonic neurons. The results indicate that instead of working independently, nonmonotonic neurons complement the function of monotonic neurons in different sound-encoding contexts. Copyright © 2017 the American Physiological Society.
NASA Astrophysics Data System (ADS)
Fujii, Ayaka; Wakatsuki, Naoto; Mizutani, Koichi
2016-01-01
A method of suppressing sound radiation to the far field of a near-field acoustic communication system using an evanescent sound field is proposed. The amplitude of the evanescent sound field generated from an infinite vibrating plate attenuates exponentially with increasing a distance from the surface of the vibrating plate. However, a discontinuity of the sound field exists at the edge of the finite vibrating plate in practice, which broadens the wavenumber spectrum. A sound wave radiates over the evanescent sound field because of broadening of the wavenumber spectrum. Therefore, we calculated the optimum distribution of the particle velocity on the vibrating plate to reduce the broadening of the wavenumber spectrum. We focused on a window function that is utilized in the field of signal analysis for reducing the broadening of the frequency spectrum. The optimization calculation is necessary for the design of window function suitable for suppressing sound radiation and securing a spatial area for data communication. In addition, a wide frequency bandwidth is required to increase the data transmission speed. Therefore, we investigated a suitable method for calculating the sound pressure level at the far field to confirm the variation of the distribution of sound pressure level determined on the basis of the window shape and frequency. The distribution of the sound pressure level at a finite distance was in good agreement with that obtained at an infinite far field under the condition generating the evanescent sound field. Consequently, the window function was optimized by the method used to calculate the distribution of the sound pressure level at an infinite far field using the wavenumber spectrum on the vibrating plate. According to the result of comparing the distributions of the sound pressure level in the cases with and without the window function, it was confirmed that the area whose sound pressure level was reduced from the maximum level to -50 dB was extended. Additionally, we designed a sound insulator so as to realize a similar distribution of the particle velocity to that obtained using the optimized window function. Sound radiation was suppressed using a sound insulator put above the vibrating surface in the simulation using the three-dimensional finite element method. On the basis of this finding, it was suggested that near-field acoustic communication which suppressed sound radiation can be realized by applying the optimized window function to the particle velocity field.
33 CFR 86.07 - Directional properties.
Code of Federal Regulations, 2011 CFR
2011-07-01
... properties. The sound pressure level of a directional whistle shall be not more than 4 dB below the sound... forward axis. The sound pressure level of the whistle in any other direction in the horizontal plane shall not be more than 10 dB less than the sound pressure level specified for the forward axis, so that the...
NASA Technical Reports Server (NTRS)
Groza, A.; Calciu, J.; Nicola, I.; Ionasek, A.
1974-01-01
Sound level measurements on noise sources on buses are used to observe the effects of attenuating acoustic pressure levels inside the bus by sound-proofing during complete repair. A spectral analysis of the sound level as a function of motor speed, bus speed along the road, and the category of the road is reported.
The sound intensity and characteristics of variable-pitch pulse oximeters.
Yamanaka, Hiroo; Haruna, Junichi; Mashimo, Takashi; Akita, Takeshi; Kinouchi, Keiko
2008-06-01
Various studies worldwide have found that sound levels in hospitals significantly exceed the World Health Organization (WHO) guidelines, and that this noise is associated with audible signals from various medical devices. The pulse oximeter is now widely used in health care; however the health effects associated with the noise from this equipment remain largely unclarified. Here, we analyzed the sounds of variable-pitch pulse oximeters, and discussed the possible associated risk of sleep disturbance, annoyance, and hearing loss. The Nellcor N 595 and Masimo SET Radical pulse oximeters were measured for equivalent continuous A-weighted sound pressure levels (L(Aeq)), loudness levels, and loudness. Pulse beep pitches were also identified using Fast Fourier Transform (FFT) analysis and compared with musical pitches as controls. Almost all alarm sounds and pulse beeps from the instruments tested exceeded 30 dBA, a level that may induce sleep disturbance and annoyance. Several alarm sounds emitted by the pulse oximeters exceeded 70 dBA, which is known to induce hearing loss. The loudness of the alarm sound of each pulse oximeter did not change in proportion to the sound volume level. The pitch of each pulse beep did not correspond to musical pitch levels. The results indicate that sounds from pulse oximeters pose a potential risk of not only sleep disturbance and annoyance but also hearing loss, and that these sounds are unnatural for human auditory perception.
The effect of spatial distribution on the annoyance caused by simultaneous sounds
NASA Astrophysics Data System (ADS)
Vos, Joos; Bronkhorst, Adelbert W.; Fedtke, Thomas
2004-05-01
A considerable part of the population is exposed to simultaneous and/or successive environmental sounds from different sources. In many cases, these sources are different with respect to their locations also. In a laboratory study, it was investigated whether the annoyance caused by the multiple sounds is affected by the spatial distribution of the sources. There were four independent variables: (1) sound category (stationary or moving), (2) sound type (stationary: lawn-mower, leaf-blower, and chain saw; moving: road traffic, railway, and motorbike), (3) spatial location (left, right, and combinations), and (4) A-weighted sound exposure level (ASEL of single sources equal to 50, 60, or 70 dB). In addition to the individual sounds in isolation, various combinations of two or three different sources within each sound category and sound level were presented for rating. The annoyance was mainly determined by sound level and sound source type. In most cases there were neither significant main effects of spatial distribution nor significant interaction effects between spatial distribution and the other variables. It was concluded that for rating the spatially distrib- uted sounds investigated, the noise dose can simply be determined by a summation of the levels for the left and right channels. [Work supported by CEU.
Psychophysiological acoustics of indoor sound due to traffic noise during sleep
NASA Astrophysics Data System (ADS)
Tulen, J. H. M.; Kumar, A.; Jurriëns, A. A.
1986-10-01
The relation between the physical characteristics of sound and an individual's perception of its as annoyance is complex and unclear. Sleep disturbance by sound is manifested in the physiological responses to the sound stimuli and the quality of sleep perceived in the morning. Both may result in deterioration of functioning during wakefulness. Therefore, psychophysiological responses to noise during sleep should be studied for the evaluation of the efficacy of sound insulation. Nocturnal sleep and indoor sound level were recorded in the homes of 12 subjects living along a highway with high traffic density. Double glazing sound insulation was used to create two experimental conditions: low insulation and high insulation. Twenty recordings were made per subject, ten recordings in each condition. During the nights with low insulation the quality of sleep was so low that both performance and mood were negatively affected. The enhancement of sound insulation was not effective enough to increase the restorative effects of sleep. The transient and peaky characteristics of traffic sound were also found to result in non-adaptive physiological responses during sleep. Sound insulation did have an effect on noise peak characteristics such as peak level, peak duration and slope. However, the number of sound peaks were found to be the same in both conditions. The relation of these sound peaks detected in the indoor recorded sound level signal to characteristics of passing vehicles was established, indicating that the sound peaks causing the psychophysiological disturbances during sleep were generated by the passing vehicles. Evidence is presented to show that the reduction in sound level is not a good measure of efficacy of sound insulation. The parameters of the sound peaks, as described in this paper, are a better representation of psychophysiological efficacy of sound insulation.
Twardella, Dorothee; Wellhoefer, Andrea; Brix, Jutta; Fromme, Hermann
2008-01-01
While no legal rules or regulations exist in Germany, voluntary measures were introduced to achieve a reduction of sound pressure levels in discotheques to levels below 100 dB(A). To evaluate the current levels in Bavarian discotheques and to find out whether these voluntary measures ensured compliance with the recommended limits, sound pressure levels were measured in 20 Bavarian discotheques between 11 p.m. and 2 a.m. With respect to the equivalent continuous A-weighted sound pressure level for each 30-minute period (L Aeq,30min ), only 4/20 discotheques remained below the limit of 100 dB(A) in all time periods. Ten discotheques had sound pressure levels below 100 dB(A) for the total measurement period (L Aeq,180min ). None of the evaluated factors (weekday, size, estimated age of attendees, the use of voluntary measures such as participation of disc jockeys in a tutorial, or the availability of a sound level meter for the DJs) was significantly associated with the maximal L Aeq, 30min . Thus, the introduction of voluntary measures was not sufficient to ensure compliance with the recommended limits of sound pressure levels.
Measor, Kevin; Yarrow, Stuart; Razak, Khaleel A
2018-05-26
Sound level processing is a fundamental function of the auditory system. To determine how the cortex represents sound level, it is important to quantify how changes in level alter the spatiotemporal structure of cortical ensemble activity. This is particularly true for echolocating bats that have control over, and often rapidly adjust, call level to actively change echo level. To understand how cortical activity may change with sound level, here we mapped response rate and latency changes with sound level in the auditory cortex of the pallid bat. The pallid bat uses a 60-30 kHz downward frequency modulated (FM) sweep for echolocation. Neurons tuned to frequencies between 30 and 70 kHz in the auditory cortex are selective for the properties of FM sweeps used in echolocation forming the FM sweep selective region (FMSR). The FMSR is strongly selective for sound level between 30 and 50 dB SPL. Here we mapped the topography of level selectivity in the FMSR using downward FM sweeps and show that neurons with more monotonic rate level functions are located in caudomedial regions of the FMSR overlapping with high frequency (50-60 kHz) neurons. Non-monotonic neurons dominate the FMSR, and are distributed across the entire region, but there is no evidence for amplitopy. We also examined how first spike latency of FMSR neurons change with sound level. The majority of FMSR neurons exhibit paradoxical latency shift wherein the latency increases with sound level. Moreover, neurons with paradoxical latency shifts are more strongly level selective and are tuned to lower sound level than neurons in which latencies decrease with level. These data indicate a clustered arrangement of neurons according to monotonicity, with no strong evidence for finer scale topography, in the FMSR. The latency analysis suggests mechanisms for strong level selectivity that is based on relative timing of excitatory and inhibitory inputs. Taken together, these data suggest how the spatiotemporal spread of cortical activity may represent sound level. Copyright © 2018. Published by Elsevier B.V.
Litton, Edward; Elliott, Rosalind; Thompson, Kelly; Watts, Nicola; Seppelt, Ian; Webb, Steven A R
2017-06-01
To use clinically accessible tools to determine unit-level and individual patient factors associated with sound levels and sleep disruption in a range of representative ICUs. A cross-sectional, observational study. Australian and New Zealand ICUs. All patients 16 years or over occupying an ICU bed on one of two Point Prevalence study days in 2015. Ambient sound was measured for 1 minute using an application downloaded to a personal mobile device. Bedside nurses also recorded the total time and number of awakening for each patient overnight. The study included 539 participants with sound level recorded using an application downloaded to a personal mobile device from 39 ICUs. Maximum and mean sound levels were 78 dB (SD, 9) and 62 dB (SD, 8), respectively. Maximum sound levels were higher in ICUs with a sleep policy or protocol compared with those without maximum sound levels 81 dB (95% CI, 79-83) versus 77 dB (95% CI, 77-78), mean difference 4 dB (95% CI, 0-2), p < 0.001. There was no significant difference in sound levels regardless of single room occupancy, mechanical ventilation status, or illness severity. Clinical nursing staff in all 39 ICUs were able to record sleep assessment in 15-minute intervals. The median time awake and number of prolonged disruptions were 3 hours (interquartile range, 1-4) and three (interquartile range, 2-5), respectively. Across a large number of ICUs, patients were exposed to high sound levels and substantial sleep disruption irrespective of factors including previous implementation of a sleep policy. Sound and sleep measurement using simple and accessible tools can facilitate future studies and could feasibly be implemented into clinical practice.
Source levels of social sounds in migrating humpback whales (Megaptera novaeangliae).
Dunlop, Rebecca A; Cato, Douglas H; Noad, Michael J; Stokes, Dale M
2013-07-01
The source level of an animal sound is important in communication, since it affects the distance over which the sound is audible. Several measurements of source levels of whale sounds have been reported, but the accuracy of many is limited because the distance to the source and the acoustic transmission loss were estimated rather than measured. This paper presents measurements of source levels of social sounds (surface-generated and vocal sounds) of humpback whales from a sample of 998 sounds recorded from 49 migrating humpback whale groups. Sources were localized using a wide baseline five hydrophone array and transmission loss was measured for the site. Social vocalization source levels were found to range from 123 to 183 dB re 1 μPa @ 1 m with a median of 158 dB re 1 μPa @ 1 m. Source levels of surface-generated social sounds ("breaches" and "slaps") were narrower in range (133 to 171 dB re 1 μPa @ 1 m) but slightly higher in level (median of 162 dB re 1 μPa @ 1 m) compared to vocalizations. The data suggest that group composition has an effect on group vocalization source levels in that singletons and mother-calf-singing escort groups tend to vocalize at higher levels compared to other group compositions.
Comprehensive measures of sound exposures in cinemas using smart phones.
Huth, Markus E; Popelka, Gerald R; Blevins, Nikolas H
2014-01-01
Sensorineural hearing loss from sound overexposure has a considerable prevalence. Identification of sound hazards is crucial, as prevention, due to a lack of definitive therapies, is the sole alternative to hearing aids. One subjectively loud, yet little studied, potential sound hazard is movie theaters. This study uses smart phones to evaluate their applicability as a widely available, validated sound pressure level (SPL) meter. Therefore, this study measures sound levels in movie theaters to determine whether sound levels exceed safe occupational noise exposure limits and whether sound levels in movie theaters differ as a function of movie, movie theater, presentation time, and seat location within the theater. Six smart phones with an SPL meter software application were calibrated with a precision SPL meter and validated as an SPL meter. Additionally, three different smart phone generations were measured in comparison to an integrating SPL meter. Two different movies, an action movie and a children's movie, were measured six times each in 10 different venues (n = 117). To maximize representativeness, movies were selected focusing on large release productions with probable high attendance. Movie theaters were selected in the San Francisco, CA, area based on whether they screened both chosen movies and to represent the largest variety of theater proprietors. Measurements were analyzed in regard to differences between theaters, location within the theater, movie, as well as presentation time and day as indirect indicator of film attendance. The smart phone measurements demonstrated high accuracy and reliability. Overall, sound levels in movie theaters do not exceed safe exposure limits by occupational standards. Sound levels vary significantly across theaters and demonstrated statistically significant higher sound levels and exposures in the action movie compared to the children's movie. Sound levels decrease with distance from the screen. However, no influence on time of day or day of the week as indirect indicator of film attendance could be found. Calibrated smart phones with an appropriate software application as used in this study can be utilized as a validated SPL meter. Because of the wide availability, smart phones in combination with the software application can provide high quantity recreational sound exposure measurements, which can facilitate the identification of potential noise hazards. Sound levels in movie theaters decrease with distance to the screen, but do not exceed safe occupational noise exposure limits. Additionally, there are significant differences in sound levels across movie theaters and movies, but not in presentation time.
Radiated BPF sound measurement of centrifugal compressor
NASA Astrophysics Data System (ADS)
Ohuchida, S.; Tanaka, K.
2013-12-01
A technique to measure radiated BPF sound from an automotive turbocharger compressor impeller is proposed in this paper. Where there are high-level background noises in the measurement environment, it is difficult to discriminate the target component from the background. Since the effort of measuring BPF sound was taken in a room with such condition in this study, no discrete BPF peak was initially found on the sound spectrum. Taking its directionality into consideration, a microphone covered with a parabolic cone was selected and using this technique, the discrete peak of BPF was clearly observed. Since the level of measured sound was amplified due to the area-integration effect, correction was needed to obtain the real level. To do so, sound measurements with and without a parabolic cone were conducted for the fixed source and their level differences were used as correction factors. Consideration is given to the sound propagation mechanism utilizing measured BPF as well as the result of a simple model experiment. The present method is generally applicable to sound measurements conducted with a high level of background noise.
Masalski, Marcin; Kipiński, Lech; Grysiński, Tomasz; Kręcicki, Tomasz
2016-05-30
Hearing tests carried out in home setting by means of mobile devices require previous calibration of the reference sound level. Mobile devices with bundled headphones create a possibility of applying the predefined level for a particular model as an alternative to calibrating each device separately. The objective of this study was to determine the reference sound level for sets composed of a mobile device and bundled headphones. Reference sound levels for Android-based mobile devices were determined using an open access mobile phone app by means of biological calibration, that is, in relation to the normal-hearing threshold. The examinations were conducted in 2 groups: an uncontrolled and a controlled one. In the uncontrolled group, the fully automated self-measurements were carried out in home conditions by 18- to 35-year-old subjects, without prior hearing problems, recruited online. Calibration was conducted as a preliminary step in preparation for further examination. In the controlled group, audiologist-assisted examinations were performed in a sound booth, on normal-hearing subjects verified through pure-tone audiometry, recruited offline from among the workers and patients of the clinic. In both the groups, the reference sound levels were determined on a subject's mobile device using the Bekesy audiometry. The reference sound levels were compared between the groups. Intramodel and intermodel analyses were carried out as well. In the uncontrolled group, 8988 calibrations were conducted on 8620 different devices representing 2040 models. In the controlled group, 158 calibrations (test and retest) were conducted on 79 devices representing 50 models. Result analysis was performed for 10 most frequently used models in both the groups. The difference in reference sound levels between uncontrolled and controlled groups was 1.50 dB (SD 4.42). The mean SD of the reference sound level determined for devices within the same model was 4.03 dB (95% CI 3.93-4.11). Statistically significant differences were found across models. Reference sound levels determined in the uncontrolled group are comparable to the values obtained in the controlled group. This validates the use of biological calibration in the uncontrolled group for determining the predefined reference sound level for new devices. Moreover, due to a relatively small deviation of the reference sound level for devices of the same model, it is feasible to conduct hearing screening on devices calibrated with the predefined reference sound level.
Tanaka, Tagayasu; Inaba, Ryoichi; Aoyama, Atsuhito
2016-01-01
Objectives: This study investigated the actual situation of noise and low-frequency sounds in firework events and their impact on pyrotechnicians. Methods: Data on firework noise and low-frequency sounds were obtained at a point located approximately 100 m away from the launch site of a firework display held in "A" City in 2013. We obtained the data by continuously measuring and analyzing the equivalent continuous sound level (Leq) and the one-third octave band of the noise and low-frequency sounds emanating from the major firework detonations, and predicted sound levels at the original launch site. Results: Sound levels of 100-115 dB and low-frequency sounds of 100-125 dB were observed at night. The maximum and mean Leq values were 97 and 95 dB, respectively. The launching noise level predicted from the sounds (85 dB) at the noise measurement point was 133 dB. Occupational exposure to noise for pyrotechnicians at the remote operation point (located 20-30 m away from the launch site) was estimated to be below 100 dB. Conclusions: Pyrotechnicians are exposed to very loud noise (>100 dB) at the launch point. We believe that it is necessary to implement measures such as fixing earplugs or earmuffs, posting a warning at the workplace, and executing a remote launching operation to prevent hearing loss caused by occupational exposure of pyrotechnicians to noise. It is predicted that both sound levels and low-frequency sounds would be reduced by approximately 35 dB at the remote operation site. PMID:27725489
Tanaka, Tagayasu; Inaba, Ryoichi; Aoyama, Atsuhito
2016-11-29
This study investigated the actual situation of noise and low-frequency sounds in firework events and their impact on pyrotechnicians. Data on firework noise and low-frequency sounds were obtained at a point located approximately 100 m away from the launch site of a firework display held in "A" City in 2013. We obtained the data by continuously measuring and analyzing the equivalent continuous sound level (Leq) and the one-third octave band of the noise and low-frequency sounds emanating from the major firework detonations, and predicted sound levels at the original launch site. Sound levels of 100-115 dB and low-frequency sounds of 100-125 dB were observed at night. The maximum and mean Leq values were 97 and 95 dB, respectively. The launching noise level predicted from the sounds (85 dB) at the noise measurement point was 133 dB. Occupational exposure to noise for pyrotechnicians at the remote operation point (located 20-30 m away from the launch site) was estimated to be below 100 dB. Pyrotechnicians are exposed to very loud noise (>100 dB) at the launch point. We believe that it is necessary to implement measures such as fixing earplugs or earmuffs, posting a warning at the workplace, and executing a remote launching operation to prevent hearing loss caused by occupational exposure of pyrotechnicians to noise. It is predicted that both sound levels and low-frequency sounds would be reduced by approximately 35 dB at the remote operation site.
Analysis of sound pressure levels emitted by children's toys.
Sleifer, Pricila; Gonçalves, Maiara Santos; Tomasi, Marinês; Gomes, Erissandra
2013-06-01
To verify the levels of sound pressure emitted by non-certified children's toys. Cross-sectional study of sound toys available at popular retail stores of the so-called informal sector. Electronic, mechanical, and musical toys were analyzed. The measurement of each product was carried out by an acoustic engineer in an acoustically isolated booth, by a decibel meter. To obtain the sound parameters of intensity and frequency, the toys were set to produce sounds at a distance of 10 and 50cm from the researcher's ear. The intensity of sound pressure [dB(A)] and the frequency in hertz (Hz) were measured. 48 toys were evaluated. The mean sound pressure 10cm from the ear was 102±10 dB(A), and at 50cm, 94±8 dB(A), with p<0.05. The level of sound pressure emitted by the majority of toys was above 85dB(A). The frequency ranged from 413 to 6,635Hz, with 56.3% of toys emitting frequency higher than 2,000Hz. The majority of toys assessed in this research emitted a high level of sound pressure.
Visualizing Sound: Demonstrations to Teach Acoustic Concepts
NASA Astrophysics Data System (ADS)
Rennoll, Valerie
Interference, a phenomenon in which two sound waves superpose to form a resultant wave of greater or lower amplitude, is a key concept when learning about the physics of sound waves. Typical interference demonstrations involve students listening for changes in sound level as they move throughout a room. Here, new tools are developed to teach this concept that provide a visual component, allowing individuals to see changes in sound level on a light display. This is accomplished using a microcontroller that analyzes sound levels collected by a microphone and displays the sound level in real-time on an LED strip. The light display is placed on a sliding rail between two speakers to show the interference occurring between two sound waves. When a long-exposure photograph is taken of the light display being slid from one end of the rail to the other, a wave of the interference pattern can be captured. By providing a visual component, these tools will help students and the general public to better understand interference, a key concept in acoustics.
Behavioral response of manatees to variations in environmental sound levels
Miksis-Olds, Jennifer L.; Wagner, Tyler
2011-01-01
Florida manatees (Trichechus manatus latirostris) inhabit coastal regions because they feed on the aquatic vegetation that grows in shallow waters, which are the same areas where human activities are greatest. Noise produced from anthropogenic and natural sources has the potential to affect these animals by eliciting responses ranging from mild behavioral changes to extreme aversion. Sound levels were calculated from recordings made throughout behavioral observation periods. An information theoretic approach was used to investigate the relationship between behavior patterns and sound level. Results indicated that elevated sound levels affect manatee activity and are a function of behavioral state. The proportion of time manatees spent feeding and milling changed in response to sound level. When ambient sound levels were highest, more time was spent in the directed, goal-oriented behavior of feeding, whereas less time was spent engaged in undirected behavior such as milling. This work illustrates how shifts in activity of individual manatees may be useful parameters for identifying impacts of noise on manatees and might inform population level effects.
Poganiatz, I; Wagner, H
2001-04-01
Interaural level differences play an important role for elevational sound localization in barn owls. The changes of this cue with sound location are complex and frequency dependent. We exploited the opportunities offered by the virtual space technique to investigate the behavioral relevance of the overall interaural level difference by fixing this parameter in virtual stimuli to a constant value or introducing additional broadband level differences to normal virtual stimuli. Frequency-specific monaural cues in the stimuli were not manipulated. We observed an influence of the broadband interaural level differences on elevational, but not on azimuthal sound localization. Since results obtained with our manipulations explained only part of the variance in elevational turning angle, we conclude that frequency-specific cues are also important. The behavioral consequences of changes of the overall interaural level difference in a virtual sound depended on the combined interaural time difference contained in the stimulus, indicating an indirect influence of temporal cues on elevational sound localization as well. Thus, elevational sound localization is influenced by a combination of many spatial cues including frequency-dependent and temporal features.
NASA Astrophysics Data System (ADS)
Lau, S. F.; Zainulabidin, M. H.; Yahya, M. N.; Zaman, I.; Azmir, N. A.; Madlan, M. A.; Ismon, M.; Kasron, M. Z.; Ismail, A. E.
2017-10-01
Giving a room proper acoustic treatment is both art and science. Acoustic design brings comfort in the built environment and reduces noise level by using sound absorbers. There is a need to give a room acoustic treatment by installing absorbers in order to decrease the reverberant sound. However, they are usually high in price which cost much for installation and there is no system to locate the optimum number and placement of sound absorbers. It would be a waste if the room is overly treated with absorbers or cause improper treatment if the room is treated with insufficient absorbers. This study aims to determine the amount of sound absorbers needed and optimum location of sound absorbers placement in order to reduce the overall sound pressure level in specified room by using ANSYS APDL software. The size of sound absorbers needed is found to be 11 m 2 by using Sabine equation and different unit sets of absorbers are applied on walls, each with the same total areas to investigate the best configurations. All three sets (single absorber, 11 absorbers and 44 absorbers) has successfully treating the room by reducing the overall sound pressure level. The greatest reduction in overall sound pressure level is that of 44 absorbers evenly distributed around the walls, which has reduced as much as 24.2 dB and the least effective configuration is single absorber whereby it has reduced the overall sound pressure level by 18.4 dB.
49 CFR 227.115 - Hearing protectors.
Code of Federal Regulations, 2011 CFR
2011-10-01
... employees exposed to sound levels that meet or exceed the action level. (c) Required use at action level. A railroad shall require the use of hearing protectors when an employee is exposed to sound levels that meet... hearing protectors when an employee is exposed to sound levels equivalent to an 8-hour TWA of 90 dB(A) or...
Prieve, Kurt; Rice, Amanda; Raynor, Peter C
2017-08-01
The aims of this study were to evaluate sound levels produced by compressed air guns in research and development (R&D) environments, replace conventional air gun models with advanced noise-reducing air nozzles, and measure changes in sound levels to assess the effectiveness of the advanced nozzles as engineering controls for noise. Ten different R&D manufacturing areas that used compressed air guns were identified and included in the study. A-weighted sound level and Z-weighted octave band measurements were taken simultaneously using a single instrument. In each area, three sets of measurements, each lasting for 20 sec, were taken 1 m away and perpendicular to the air stream of the conventional air gun while a worker simulated typical air gun work use. Two different advanced noise-reducing air nozzles were then installed. Sound level and octave band data were collected for each of these nozzles using the same methods as for the original air guns. Both of the advanced nozzles provided sound level reductions of about 7 dBA, on average. The highest noise reductions measured were 17.2 dBA for one model and 17.7 dBA for the other. In two areas, the advanced nozzles yielded no sound level reduction, or they produced small increases in sound level. The octave band data showed strong similarities in sound level among all air gun nozzles within the 10-1,000 Hz frequency range. However, the advanced air nozzles generally had lower noise contributions in the 1,000-20,000 Hz range. The observed decreases at these higher frequencies caused the overall sound level reductions that were measured. Installing new advanced noise-reducing air nozzles can provide large sound level reductions in comparison to existing conventional nozzles, which has direct benefit for hearing conservation efforts.
Darcy, Ashley E; Hancock, Lauren E; Ware, Emily J
2008-10-01
To examine the baseline acoustic environment in several mid-Atlantic region neonatal intensive care units (NICUs) and investigate the perceived factors contributing to noise levels in these NICUs. Quantitative data were collected from 3 urban, mid-Atlantic level IIIB and level IIIC NICUs. Qualitative data were collected via interview from 2 RNs employed in each of the study NICUs. This was an exploratory descriptive study utilizing a mixed-methods approach. A quantitative method was used for sound-level data collection, and a qualitative method was utilized during interviews with nurses to examine perceptions of factors contributing to noise. Ambient sound levels, measured in decibels, were taken at 5-minute intervals over a 2-hour period during both day and night shifts in a central location at each NICU. In addition, nurses were interviewed using a standardized interview questionnaire, and these interviews were then reviewed to determine themes regarding perceived factors contributing to sound levels. Hourly mean sound levels in each NICU ranged from 53.9 dB to 60.6 dB, with no statistically significant difference between noise levels recorded on day shift versus night shift, and no statistically significant difference among sites. Qualitative data showed that nurses' believed day shift to be louder than night shift and many perceived their own NICU as "pretty quiet." Key contributing factors to increased sound levels were stated as monitors or alarms, performing invasive procedures, presence of family, nurses or doctors giving report or rounds, and ringing phones. Noise levels were found to be above the American Academy of Pediatrics-recommended 45-dB level and often louder than the 50-dB level, which should not be exceeded more than 10% of the time. The recommended impulse maximum of 65 dB was also exceeded. Environmental Protection Agency recommendations for hospitals include sound levels no louder than 35 dB on night shift; this standard was also violated. Elevated sound levels need to be addressed in individual NICUs around the country. Further exploratory studies, as well as research regarding effective methods of decreasing sound levels in the NICU environment, are necessary. NICUs can implement behavioral and structural changes that can decrease the sound levels in the NICU environment and decrease the potential for exposure of patients to the harmful physiological effects of increased sound levels.
Darcy, Ashley E; Hancock, Lauren E; Ware, Emily J
2008-06-01
To examine the baseline acoustic environment in several mid-Atlantic region neonatal intensive care units (NICUs) and investigate the perceived factors contributing to noise levels in these NICUs. Quantitative data were collected from 3 urban, mid-Atlantic level IIIB and level IIIC NICUs. Qualitative data were collected via interview from 2 RNs employed in each of the study NICUs. This was an exploratory descriptive study utilizing a mixed-methods approach. A quantitative method was used for sound-level data collection, and a qualitative method was utilized during interviews with nurses to examine perceptions of factors contributing to noise. Ambient sound levels, measured in decibels, were taken at 5-minute intervals over a 2-hour period during both day and night shifts in a central location at each NICU. In addition, nurses were interviewed using a standardized interview questionnaire, and these interviews were then reviewed to determine themes regarding perceived factors contributing to sound levels. Hourly mean sound levels in each NICU ranged from 53.9 dB to 60.6 dB, with no statistically significant difference between noise levels recorded on day shift versus night shift, and no statistically significant difference among sites. Qualitative data showed that nurses' believed day shift to be louder than night shift and many perceived their own NICU as "pretty quiet." Key contributing factors to increased sound levels were stated as monitors or alarms, performing invasive procedures, presence of family, nurses or doctors giving report or rounds, and ringing phones. Noise levels were found to be above the American Academy of Pediatrics--recommended 45-dB level and often louder than the 50-dB level, which should not be exceeded more than 10% of the time. The recommended impulse maximum of 65 dB was also exceeded. Environmental Protection Agency recommendations for hospitals include sound levels no louder than 35 dB on night shift; this standard was also violated. Elevated sound levels need to be addressed in individual NICUs around the country. Further exploratory studies, as well as research regarding effective methods of decreasing sound levels in the NICU environment, are necessary. NICUs can implement behavioral and structural changes that can decrease the sound levels in the NICU environment and decrease the potential for exposure of patients to the harmful physiological effects of increased sound levels.
Handbook of aircraft noise metrics
NASA Technical Reports Server (NTRS)
Bennett, R. L.; Pearsons, K. S.
1981-01-01
Information is presented on 22 noise metrics that are associated with the measurement and prediction of the effects of aircraft noise. Some of the instantaneous frequency weighted sound level measures, such as A-weighted sound level, are used to provide multiple assessment of the aircraft noise level. Other multiple event metrics, such as day-night average sound level, were designed to relate sound levels measured over a period of time to subjective responses in an effort to determine compatible land uses and aid in community planning. The various measures are divided into: (1) instantaneous sound level metrics; (2) duration corrected single event metrics; (3) multiple event metrics; and (4) speech communication metrics. The scope of each measure is examined in terms of its: definition, purpose, background, relationship to other measures, calculation method, example, equipment, references, and standards.
Handbook of aircraft noise metrics
NASA Astrophysics Data System (ADS)
Bennett, R. L.; Pearsons, K. S.
1981-03-01
Information is presented on 22 noise metrics that are associated with the measurement and prediction of the effects of aircraft noise. Some of the instantaneous frequency weighted sound level measures, such as A-weighted sound level, are used to provide multiple assessment of the aircraft noise level. Other multiple event metrics, such as day-night average sound level, were designed to relate sound levels measured over a period of time to subjective responses in an effort to determine compatible land uses and aid in community planning. The various measures are divided into: (1) instantaneous sound level metrics; (2) duration corrected single event metrics; (3) multiple event metrics; and (4) speech communication metrics. The scope of each measure is examined in terms of its: definition, purpose, background, relationship to other measures, calculation method, example, equipment, references, and standards.
Calibration of Clinical Audio Recording and Analysis Systems for Sound Intensity Measurement.
Maryn, Youri; Zarowski, Andrzej
2015-11-01
Sound intensity is an important acoustic feature of voice/speech signals. Yet recordings are performed with different microphone, amplifier, and computer configurations, and it is therefore crucial to calibrate sound intensity measures of clinical audio recording and analysis systems on the basis of output of a sound-level meter. This study was designed to evaluate feasibility, validity, and accuracy of calibration methods, including audiometric speech noise signals and human voice signals under typical speech conditions. Calibration consisted of 3 comparisons between data from 29 measurement microphone-and-computer systems and data from the sound-level meter: signal-specific comparison with audiometric speech noise at 5 levels, signal-specific comparison with natural voice at 3 levels, and cross-signal comparison with natural voice at 3 levels. Intensity measures from recording systems were then linearly converted into calibrated data on the basis of these comparisons, and validity and accuracy of calibrated sound intensity were investigated. Very strong correlations and quasisimilarity were found between calibrated data and sound-level meter data across calibration methods and recording systems. Calibration of clinical sound intensity measures according to this method is feasible, valid, accurate, and representative for a heterogeneous set of microphones and data acquisition systems in real-life circumstances with distinct noise contexts.
Noise exposure estimates of urban MP3 player users.
Levey, Sandra; Levey, Tania; Fligor, Brian J
2011-02-01
To examine the sound level and duration of use of personal listening devices (PLDs) by 189 college students, ages 18-53 years, as they entered a New York City college campus, to determine whether noise exposure from PLDs was in excess of recommended exposure limits and what factors might influence exposure. Free-field equivalent sound levels from PLD headphones were measured on a mannequin with a calibrated sound level meter. Participants reported demographic information, whether they had just come off the subway, the type of PLD and earphones used, and duration per day and days per week they used their PLDs. Based on measured free-field equivalent sound levels from PLD headphones and the reported PLD use, per day 58.2% of participants exceeded 85 dB A-weighted 8-hr equivalent sound levels (L(Aeq)), and per week 51.9% exceeded 85 dB A-weighted 40-hr equivalent continuous sound levels (L(Awkn)). The majority of PLD users exceeded recommended sound exposure limits, suggesting that they were at increased risk for noise-induced hearing loss. Analyses of the demographics of these participants and mode of transportation to campus failed to indicate any particular gender differences in PLD use or in mode of transportation influencing sound exposure.
NASA Astrophysics Data System (ADS)
Breitzke, Monika; Bohlen, Thomas
2010-05-01
Modelling sound propagation in the ocean is an essential tool to assess the potential risk of air-gun shots on marine mammals. Based on a 2.5-D finite-difference code a full waveform modelling approach is presented, which determines both sound exposure levels of single shots and cumulative sound exposure levels of multiple shots fired along a seismic line. Band-limited point source approximations of compact air-gun clusters deployed by R/V Polarstern in polar regions are used as sound sources. Marine mammals are simulated as static receivers. Applications to deep and shallow water models including constant and depth-dependent sound velocity profiles of the Southern Ocean show dipole-like directivities in case of single shots and tubular cumulative sound exposure level fields beneath the seismic line in case of multiple shots. Compared to a semi-infinite model an incorporation of seafloor reflections enhances the seismically induced noise levels close to the sea surface. Refraction due to sound velocity gradients and sound channelling in near-surface ducts are evident, but affect only low to moderate levels. Hence, exposure zone radii derived for different hearing thresholds are almost independent of the sound velocity structure. With decreasing thresholds radii increase according to a spherical 20 log10 r law in case of single shots and according to a cylindrical 10 log10 r law in case of multiple shots. A doubling of the shot interval diminishes the cumulative sound exposure levels by -3 dB and halves the radii. The ocean bottom properties only slightly affect the radii in shallow waters, if the normal incidence reflection coefficient exceeds 0.2.
The sound exposure of the audience at a music festival.
Mercier, V; Luy, D; Hohmann, B W
2003-01-01
During the Paleo Festival in Nyon, Switzerland, which took place from 24th to 29th July 2001, ten volunteers were equipped each evening with small sound level meters which continuously monitored their sound exposure as they circulated among the various festival events. Sound levels at the mixing console and at the place where people are most heavily exposed (in front of the speakers) were measured simultaneously. In addition, a sample of 601 people from the audience were interviewed over the six days of the festival and asked their opinion of sound level and quality, as well as provide details of where in the arena they preferred to listen to the concerts, whether they used ear plugs, if they had experienced any tinnitus, and if so how long it had persisted. The individual sound exposure during a typical evening was on average 95 dB(A) although 8% of the volunteers were exposed to sound levels higher then 100 dB(A). Only 5% of the audience wore ear plugs throughout the concert while 34% used them occasionally. While some 36% of the people interviewed reported that they had experienced tinnitus after listening to loud music, the majority found both the music quality and the sound level good. The sound level limit of 100 dB(A) at the place where the people are most heavily exposed seems to be a good compromise between the public heath issue, the demands of artists and organisers, and the expectations of the public. However, considering the average sound levels to which the public are exposed during a single evening, it is recommended that ear plugs be used by concert-goers who attend more than one day of the festival.
[Acoustical parameters of toys].
Harazin, Barbara
2010-01-01
Toys play an important role in the development of the sight and hearing concentration in children. They also support the development of manipulation, gently influence a child and excite its emotional activities. A lot of toys emit various sounds. The aim of the study was to assess sound levels produced by sound-emitting toys used by young children. Acoustical parameters of noise were evaluated for 16 sound-emitting plastic toys in laboratory conditions. The noise level was recorded at four different distances, 10, 20, 25 and 30 cm, from the toy. Measurements of A-weighted sound pressure levels and noise levels in octave band in the frequency range from 31.5 Hz to 16 kHz were performed at each distance. Taking into consideration the highest equivalent A-weighted sound levels produced by tested toys, they can be divided into four groups: below 70 dB (6 toys), from 70 to 74 dB (4 toys), from 75 to 84 dB (3 toys) and from 85 to 94 dB (3 toys). The majority of toys (81%) emitted dominant sound levels in octave band at the frequency range from 2 kHz to 4 kHz. Sound-emitting toys produce the highest acoustic energy at the frequency range of the highest susceptibility of the auditory system. Noise levels produced by some toys can be dangerous to children's hearing.
Mooney, T Aran; Samson, Julia E; Schlunk, Andrea D; Zacarias, Samantha
2016-07-01
Sound is an abundant cue in the marine environment, yet we know little regarding the frequency range and levels which induce behavioral responses in ecologically key marine invertebrates. Here we address the range of sounds that elicit unconditioned behavioral responses in squid Doryteuthis pealeii, the types of responses generated, and how responses change over multiple sound exposures. A variety of response types were evoked, from inking and jetting to body pattern changes and fin movements. Squid responded to sounds from 80 to 1000 Hz, with response rates diminishing at the higher and lower ends of this frequency range. Animals responded to the lowest sound levels in the 200-400 Hz range. Inking, an escape response, was confined to the lower frequencies and highest sound levels; jetting was more widespread. Response latencies were variable but typically occurred after 0.36 s (mean) for jetting and 0.14 s for body pattern changes; pattern changes occurred significantly faster. These results demonstrate that squid can exhibit a range of behavioral responses to sound include fleeing, deimatic and protean behaviors, all of which are associated with predator evasion. Response types were frequency and sound level dependent, reflecting a relative loudness concept to sound perception in squid.
Schouten, Ben; Troje, Nikolaus F.; Vroomen, Jean; Verfaillie, Karl
2011-01-01
Background The focus in the research on biological motion perception traditionally has been restricted to the visual modality. Recent neurophysiological and behavioural evidence, however, supports the idea that actions are not represented merely visually but rather audiovisually. The goal of the present study was to test whether the perceived in-depth orientation of depth-ambiguous point-light walkers (plws) is affected by the presentation of looming or receding sounds synchronized with the footsteps. Methodology/Principal Findings In Experiment 1 orthographic frontal/back projections of plws were presented either without sound or with sounds of which the intensity level was rising (looming), falling (receding) or stationary. Despite instructions to ignore the sounds and to only report the visually perceived in-depth orientation, plws accompanied with looming sounds were more often judged to be facing the viewer whereas plws paired with receding sounds were more often judged to be facing away from the viewer. To test whether the effects observed in Experiment 1 act at a perceptual level rather than at the decisional level, in Experiment 2 observers perceptually compared orthographic plws without sound or paired with either looming or receding sounds to plws without sound but with perspective cues making them objectively either facing towards or facing away from the viewer. Judging whether either an orthographic plw or a plw with looming (receding) perspective cues is visually most looming becomes harder (easier) when the orthographic plw is paired with looming sounds. Conclusions/Significance The present results suggest that looming and receding sounds alter the judgements of the in-depth orientation of depth-ambiguous point-light walkers. While looming sounds are demonstrated to act at a perceptual level and make plws look more looming, it remains a challenge for future research to clarify at what level in the processing hierarchy receding sounds affect how observers judge the in-depth perception of plws. PMID:21373181
Measurements of humpback whale song sound levels received by a calf in association with a singer.
Chen, Jessica; Pack, Adam A; Au, Whitlow W L; Stimpert, Alison K
2016-11-01
Male humpback whales produce loud "songs" on the wintering grounds and some sing while escorting mother-calf pairs, exposing them to near-continuous sounds at close proximity. An Acousonde acoustic and movement recording tag deployed on a calf off Maui, Hawaii captured sounds produced by a singing male escort. Root-mean-square received levels ranged from 126 to 158 dB re 1 μPa. These levels represent rare direct measurements of sound to which a newly born humpback calf may be naturally exposed by a conspecific, and may provide a basis for informed decisions regarding anthropogenic sound levels projected near calves.
Aging Affects Adaptation to Sound-Level Statistics in Human Auditory Cortex.
Herrmann, Björn; Maess, Burkhard; Johnsrude, Ingrid S
2018-02-21
Optimal perception requires efficient and adaptive neural processing of sensory input. Neurons in nonhuman mammals adapt to the statistical properties of acoustic feature distributions such that they become sensitive to sounds that are most likely to occur in the environment. However, whether human auditory responses adapt to stimulus statistical distributions and how aging affects adaptation to stimulus statistics is unknown. We used MEG to study how exposure to different distributions of sound levels affects adaptation in auditory cortex of younger (mean: 25 years; n = 19) and older (mean: 64 years; n = 20) adults (male and female). Participants passively listened to two sound-level distributions with different modes (either 15 or 45 dB sensation level). In a control block with long interstimulus intervals, allowing neural populations to recover from adaptation, neural response magnitudes were similar between younger and older adults. Critically, both age groups demonstrated adaptation to sound-level stimulus statistics, but adaptation was altered for older compared with younger people: in the older group, neural responses continued to be sensitive to sound level under conditions in which responses were fully adapted in the younger group. The lack of full adaptation to the statistics of the sensory environment may be a physiological mechanism underlying the known difficulty that older adults have with filtering out irrelevant sensory information. SIGNIFICANCE STATEMENT Behavior requires efficient processing of acoustic stimulation. Animal work suggests that neurons accomplish efficient processing by adjusting their response sensitivity depending on statistical properties of the acoustic environment. Little is known about the extent to which this adaptation to stimulus statistics generalizes to humans, particularly to older humans. We used MEG to investigate how aging influences adaptation to sound-level statistics. Listeners were presented with sounds drawn from sound-level distributions with different modes (15 vs 45 dB). Auditory cortex neurons adapted to sound-level statistics in younger and older adults, but adaptation was incomplete in older people. The data suggest that the aging auditory system does not fully capitalize on the statistics available in sound environments to tune the perceptual system dynamically. Copyright © 2018 the authors 0270-6474/18/381989-11$15.00/0.
Transfer of knowledge from sound quality measurement to noise impact evaluation
NASA Astrophysics Data System (ADS)
Genuit, Klaus
2004-05-01
It is well known that the measurement and analysis of sound quality requires a complex procedure with consideration of the physical, psychoacoustical and psychological aspects of sound. Sound quality cannot be described only by a simple value based on A-weighted sound pressure level measurements. The A-weighted sound pressure level is sufficient to predict the probabilty that the human ear could be damaged by sound but the A-weighted level is not the correct descriptor for the annoyance of a complex sound situation given by several different sound events at different and especially moving positions (soundscape). On the one side, the consideration of the spectral distribution and the temporal pattern (psychoacoustics) is requested and, on the other side, the subjective attitude with respect to the sound situation, the expectation and experience of the people (psychology) have to be included in context with the complete noise impact evaluation. This paper describes applications of the newest methods of sound quality measurements-as it is well introduced at the car manufacturers-based on artifical head recordings and signal processing comparable to the human hearing used in noisy environments like community/traffic noise.
The hearing threshold of a harbor porpoise (Phocoena phocoena) for impulsive sounds (L).
Kastelein, Ronald A; Gransier, Robin; Hoek, Lean; de Jong, Christ A F
2012-08-01
The distance at which harbor porpoises can hear underwater detonation sounds is unknown, but depends, among other factors, on the hearing threshold of the species for impulsive sounds. Therefore, the underwater hearing threshold of a young harbor porpoise for an impulsive sound, designed to mimic a detonation pulse, was quantified by using a psychophysical technique. The synthetic exponential pulse with a 5 ms time constant was produced and transmitted by an underwater projector in a pool. The resulting underwater sound, though modified by the response of the projection system and by the pool, exhibited the characteristic features of detonation sounds: A zero to peak sound pressure level of at least 30 dB (re 1 s(-1)) higher than the sound exposure level, and a short duration (34 ms). The animal's 50% detection threshold for this impulsive sound occurred at a received unweighted broadband sound exposure level of 60 dB re 1 μPa(2)s. It is shown that the porpoise's audiogram for short-duration tonal signals [Kastelein et al., J. Acoust. Soc. Am. 128, 3211-3222 (2010)] can be used to estimate its hearing threshold for impulsive sounds.
Threshold for onset of injury in Chinook salmon from exposure to impulsive pile driving sounds.
Halvorsen, Michele B; Casper, Brandon M; Woodley, Christa M; Carlson, Thomas J; Popper, Arthur N
2012-01-01
The risk of effects to fishes and other aquatic life from impulsive sound produced by activities such as pile driving and seismic exploration is increasing throughout the world, particularly with the increased exploitation of oceans for energy production. At the same time, there are few data that provide insight into the effects of these sounds on fishes. The goal of this study was to provide quantitative data to define the levels of impulsive sound that could result in the onset of barotrauma to fish. A High Intensity Controlled Impedance Fluid filled wave Tube was developed that enabled laboratory simulation of high-energy impulsive sound that were characteristic of aquatic far-field, plane-wave acoustic conditions. The sounds used were based upon the impulsive sounds generated by an impact hammer striking a steel shell pile. Neutrally buoyant juvenile Chinook salmon (Oncorhynchus tshawytscha) were exposed to impulsive sounds and subsequently evaluated for barotrauma injuries. Observed injuries ranged from mild hematomas at the lowest sound exposure levels to organ hemorrhage at the highest sound exposure levels. Frequency of observed injuries were used to compute a biological response weighted index (RWI) to evaluate the physiological impact of injuries at the different exposure levels. As single strike and cumulative sound exposure levels (SEL(ss), SEL(cum) respectively) increased, RWI values increased. Based on the results, tissue damage associated with adverse physiological costs occurred when the RWI was greater than 2. In terms of sound exposure levels a RWI of 2 was achieved for 1920 strikes by 177 dB re 1 µPa(2)⋅s SEL(ss) yielding a SEL(cum) of 210 dB re 1 µPa(2)⋅s, and for 960 strikes by 180 dB re 1 µPa(2)⋅s SEL(ss) yielding a SEL(cum) of 210 dB re 1 µPa(2)⋅s. These metrics define thresholds for onset of injury in juvenile Chinook salmon.
Threshold for Onset of Injury in Chinook Salmon from Exposure to Impulsive Pile Driving Sounds
Halvorsen, Michele B.; Casper, Brandon M.; Woodley, Christa M.; Carlson, Thomas J.; Popper, Arthur N.
2012-01-01
The risk of effects to fishes and other aquatic life from impulsive sound produced by activities such as pile driving and seismic exploration is increasing throughout the world, particularly with the increased exploitation of oceans for energy production. At the same time, there are few data that provide insight into the effects of these sounds on fishes. The goal of this study was to provide quantitative data to define the levels of impulsive sound that could result in the onset of barotrauma to fish. A High Intensity Controlled Impedance Fluid filled wave Tube was developed that enabled laboratory simulation of high-energy impulsive sound that were characteristic of aquatic far-field, plane-wave acoustic conditions. The sounds used were based upon the impulsive sounds generated by an impact hammer striking a steel shell pile. Neutrally buoyant juvenile Chinook salmon (Oncorhynchus tshawytscha) were exposed to impulsive sounds and subsequently evaluated for barotrauma injuries. Observed injuries ranged from mild hematomas at the lowest sound exposure levels to organ hemorrhage at the highest sound exposure levels. Frequency of observed injuries were used to compute a biological response weighted index (RWI) to evaluate the physiological impact of injuries at the different exposure levels. As single strike and cumulative sound exposure levels (SELss, SELcum respectively) increased, RWI values increased. Based on the results, tissue damage associated with adverse physiological costs occurred when the RWI was greater than 2. In terms of sound exposure levels a RWI of 2 was achieved for 1920 strikes by 177 dB re 1 µPa2⋅s SELss yielding a SELcum of 210 dB re 1 µPa2⋅s, and for 960 strikes by 180 dB re 1 µPa2⋅s SELss yielding a SELcum of 210 dB re 1 µPa2⋅s. These metrics define thresholds for onset of injury in juvenile Chinook salmon. PMID:22745695
Statistical Analysis for Subjective and Objective Evaluations of Dental Drill Sounds.
Yamada, Tomomi; Kuwano, Sonoko; Ebisu, Shigeyuki; Hayashi, Mikako
2016-01-01
The sound produced by a dental air turbine handpiece (dental drill) can markedly influence the sound environment in a dental clinic. Indeed, many patients report that the sound of a dental drill elicits an unpleasant feeling. Although several manufacturers have attempted to reduce the sound pressure levels produced by dental drills during idling based on ISO 14457, the sound emitted by such drills under active drilling conditions may negatively influence the dental clinic sound environment. The physical metrics related to the unpleasant impressions associated with dental drill sounds have not been determined. In the present study, psychological measurements of dental drill sounds were conducted with the aim of facilitating improvement of the sound environment at dental clinics. Specifically, we examined the impressions elicited by the sounds of 12 types of dental drills in idling and drilling conditions using a semantic differential. The analysis revealed that the impressions of dental drill sounds varied considerably between idling and drilling conditions and among the examined drills. This finding suggests that measuring the sound of a dental drill in idling conditions alone may be insufficient for evaluating the effects of the sound. We related the results of the psychological evaluations to those of measurements of the physical metrics of equivalent continuous A-weighted sound pressure levels (LAeq) and sharpness. Factor analysis indicated that impressions of the dental drill sounds consisted of two factors: "metallic and unpleasant" and "powerful". LAeq had a strong relationship with "powerful impression", calculated sharpness was positively related to "metallic impression", and "unpleasant impression" was predicted by the combination of both LAeq and calculated sharpness. The present analyses indicate that, in addition to a reduction in sound pressure level, refining the frequency components of dental drill sounds is important for creating a comfortable sound environment in dental clinics.
14 CFR 36.6 - Incorporation by reference.
Code of Federal Regulations, 2010 CFR
2010-01-01
... No. 179, entitled “Precision Sound Level Meters,” dated 1973. (ii) IEC Publication No. 225, entitled... 1966. (iii) IEC Publication No. 651, entitled “Sound Level Meters,” first edition, dated 1979. (iv) IEC... edition, dated 1976. (v) IEC Publication No. 804, entitled “Integrating-averaging Sound Level Meters...
49 CFR 210.25 - Measurement criteria and procedures.
Code of Federal Regulations, 2011 CFR
2011-10-01
... American National Standard Institute Standards, “Method for Measurement of Sound Pressure Levels,” (ANSI S1... measurement indicating a violation. (ii) The sound level measurement system shall be checked not less than... calibrator of the microphone coupler type designed for the sound level measurement system in use shall be...
49 CFR 325.25 - Calibration of measurement systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Standard Institute Standard Methods for Measurements of Sound Pressure Levels (ANSI S1.13-1971) for field... sound level measurement system must be calibrated and appropriately adjusted at one or more frequencies... 5-15 minutes thereafter, until it has been determined that the sound level measurement system has...
49 CFR 325.25 - Calibration of measurement systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Standard Institute Standard Methods for Measurements of Sound Pressure Levels (ANSI S1.13-1971) for field... sound level measurement system must be calibrated and appropriately adjusted at one or more frequencies... 5-15 minutes thereafter, until it has been determined that the sound level measurement system has...
49 CFR 325.39 - Measurement procedure; highway operations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... shall be made of the sound level generated by a motor vehicle operating through the measurement area on..., acceleration or deceleration. (b) The sound level generated by the motor vehicle is the highest reading observed on the sound level measurement system as the vehicle passes through the measurement area...
49 CFR 325.39 - Measurement procedure; highway operations.
Code of Federal Regulations, 2011 CFR
2011-10-01
... shall be made of the sound level generated by a motor vehicle operating through the measurement area on..., acceleration or deceleration. (b) The sound level generated by the motor vehicle is the highest reading observed on the sound level measurement system as the vehicle passes through the measurement area...
24 CFR 51.103 - Criteria and standards.
Code of Federal Regulations, 2011 CFR
2011-04-01
...-night average sound level produced as the result of the accumulation of noise from all sources contributing to the external noise environment at the site. Day-night average sound level, abbreviated as DNL and symbolized as Ldn, is the 24-hour average sound level, in decibels, obtained after addition of 10...
Calculating far-field radiated sound pressure levels from NASTRAN output
NASA Technical Reports Server (NTRS)
Lipman, R. R.
1986-01-01
FAFRAP is a computer program which calculates far field radiated sound pressure levels from quantities computed by a NASTRAN direct frequency response analysis of an arbitrarily shaped structure. Fluid loading on the structure can be computed directly by NASTRAN or an added-mass approximation to fluid loading on the structure can be used. Output from FAFRAP includes tables of radiated sound pressure levels and several types of graphic output. FAFRAP results for monopole and dipole sources compare closely with an explicit calculation of the radiated sound pressure level for those sources.
24 CFR Appendix I to Subpart B of... - Definition of Acoustical Quantities
Code of Federal Regulations, 2010 CFR
2010-04-01
... micropascals. Day-night average sound level, abbreviated as DNL, and symbolized mathematically as Ldn is... day-night average sound level produced by the loud impulsive sounds shall have 8 decibels added to it...
The acoustic performance of double-skin facades: A design support tool for architects
NASA Astrophysics Data System (ADS)
Batungbakal, Aireen
This study assesses and validates the influence of measuring sound in the urban environment and the influence of glass facade components in reducing sound transmission to the indoor environment. Among the most reported issues affecting workspaces, increased awareness to minimize noise led building designers to reconsider the design of building envelopes and its site environment. Outdoor sound conditions, such as traffic noise, challenge designers to accurately estimate the capability of glass facades in acquiring an appropriate indoor sound quality. Indicating the density of the urban environment, field-tests acquired existing sound levels in areas of high commercial development, employment, and traffic activity, establishing a baseline for sound levels common in urban work areas. Composed from the direct sound transmission loss of glass facades simulated through INSUL, a sound insulation software, data is utilized as an informative tool correlating the response of glass facade components towards existing outdoor sound levels of a project site in order to achieve desired indoor sound levels. This study progresses to link the disconnection in validating the acoustic performance of glass facades early in a project's design, from conditioned settings such as field-testing and simulations to project completion. Results obtained from the study's facade simulations and facade comparison supports that acoustic comfort is not limited to a singular solution, but multiple design options responsive to its environment.
Brief report: sound output of infant humidifiers.
Royer, Allison K; Wilson, Paul F; Royer, Mark C; Miyamoto, Richard T
2015-06-01
The sound pressure levels (SPLs) of common infant humidifiers were determined to identify the likely sound exposure to infants and young children. This primary investigative research study was completed at a tertiary-level academic medical center otolaryngology and audiology laboratory. Five commercially available humidifiers were obtained from brick-and-mortar infant supply stores. Sound levels were measured at 20-, 100-, and 150-cm distances at all available humidifier settings. Two of 5 (40%) humidifiers tested had SPL readings greater than the recommended hospital infant nursery levels (50 dB) at distances up to 100 cm. In this preliminary study, it was demonstrated that humidifiers marketed for infant nurseries may produce appreciably high decibel levels. Further characterization of the effect of humidifier design on SPLs and further elucidation of ambient sound levels associated with hearing risk are necessary before definitive conclusions and recommendations can be made. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.
49 CFR 325.79 - Application of correction factors.
Code of Federal Regulations, 2011 CFR
2011-10-01
... illustrate the application of correction factors to sound level measurement readings: (1) Example 1—Highway operations. Assume that a motor vehicle generates a maximum observed sound level reading of 86 dB(A) during a... of the test site is acoustically “hard.” The corrected sound level generated by the motor vehicle...
49 CFR 325.79 - Application of correction factors.
Code of Federal Regulations, 2010 CFR
2010-10-01
... illustrate the application of correction factors to sound level measurement readings: (1) Example 1—Highway operations. Assume that a motor vehicle generates a maximum observed sound level reading of 86 dB(A) during a... of the test site is acoustically “hard.” The corrected sound level generated by the motor vehicle...
The rotary subwoofer: a controllable infrasound source.
Park, Joseph; Garcés, Milton; Thigpen, Bruce
2009-04-01
The rotary subwoofer is a novel acoustic transducer capable of projecting infrasonic signals at high sound pressure levels. The projector produces higher acoustic particle velocities than conventional transducers which translate into higher radiated sound pressure levels. This paper characterizes measured performance of a rotary subwoofer and presents a model to predict sound pressure levels.
EEG oscillations entrain their phase to high-level features of speech sound.
Zoefel, Benedikt; VanRullen, Rufin
2016-01-01
Phase entrainment of neural oscillations, the brain's adjustment to rhythmic stimulation, is a central component in recent theories of speech comprehension: the alignment between brain oscillations and speech sound improves speech intelligibility. However, phase entrainment to everyday speech sound could also be explained by oscillations passively following the low-level periodicities (e.g., in sound amplitude and spectral content) of auditory stimulation-and not by an adjustment to the speech rhythm per se. Recently, using novel speech/noise mixture stimuli, we have shown that behavioral performance can entrain to speech sound even when high-level features (including phonetic information) are not accompanied by fluctuations in sound amplitude and spectral content. In the present study, we report that neural phase entrainment might underlie our behavioral findings. We observed phase-locking between electroencephalogram (EEG) and speech sound in response not only to original (unprocessed) speech but also to our constructed "high-level" speech/noise mixture stimuli. Phase entrainment to original speech and speech/noise sound did not differ in the degree of entrainment, but rather in the actual phase difference between EEG signal and sound. Phase entrainment was not abolished when speech/noise stimuli were presented in reverse (which disrupts semantic processing), indicating that acoustic (rather than linguistic) high-level features play a major role in the observed neural entrainment. Our results provide further evidence for phase entrainment as a potential mechanism underlying speech processing and segmentation, and for the involvement of high-level processes in the adjustment to the rhythm of speech. Copyright © 2015 Elsevier Inc. All rights reserved.
Decadal trends in Indian Ocean ambient sound.
Miksis-Olds, Jennifer L; Bradley, David L; Niu, Xiaoyue Maggie
2013-11-01
The increase of ocean noise documented in the North Pacific has sparked concern on whether the observed increases are a global or regional phenomenon. This work provides evidence of low frequency sound increases in the Indian Ocean. A decade (2002-2012) of recordings made off the island of Diego Garcia, UK in the Indian Ocean was parsed into time series according to frequency band and sound level. Quarterly sound level comparisons between the first and last years were also performed. The combination of time series and temporal comparison analyses over multiple measurement parameters produced results beyond those obtainable from a single parameter analysis. The ocean sound floor has increased over the past decade in the Indian Ocean. Increases were most prominent in recordings made south of Diego Garcia in the 85-105 Hz band. The highest sound level trends differed between the two sides of the island; the highest sound levels decreased in the north and increased in the south. Rate, direction, and magnitude of changes among the multiple parameters supported interpretation of source functions driving the trends. The observed sound floor increases are consistent with concurrent increases in shipping, wind speed, wave height, and blue whale abundance in the Indian Ocean.
Decreasing sound and vibration during ground transport of infants with very low birth weight.
Prehn, J; McEwen, I; Jeffries, L; Jones, M; Daniels, T; Goshorn, E; Marx, C
2015-02-01
To measure the effectiveness of modifications to reduce sound and vibration during interhospital ground transport of a simulated infant with very low birth weight (VLBW) and a gestational age of 30 weeks, a period of high susceptibility to germinal matrix and intraventricular hemorrhage. Researchers measured vibration and sound levels during infant transport, and compared levels after modifications to the transport incubator mattresses, addition of vibration isolators under incubator wheels, addition of mass to the incubator mattress and addition of incubator acoustic cover. Modifications did not decrease sound levels inside the transport incubator during transport. The combination of a gel mattress over an air chambered mattress was effective in decreasing vibration levels for the 1368 g simulated infant. Transport mattress effectiveness in decreasing vibration is influenced by infant weight. Modifications that decrease vibration for infants weighing 2000 g are not effective for infants with VLBW. Sound levels are not affected by incubator covers, suggesting that sound is transmitted into the incubator as a low-frequency vibration through the incubator's contact with the ambulance. Medical transportation can apply industrial methods of vibration and sound control to protect infants with VLBW from excessive physical strain of transport during vulnerable periods of development.
Noise Levels in Patient Rooms and at Nursing Stations at Three VA Medical Centers.
Hill, Jennifer N; LaVela, Sherri L
2015-01-01
To conduct an assessment of sound, dB(A) levels, in two areas of the hospital: patient rooms and nurse stations using sound meters (SMs). The World Health Organization (WHO) recommends sound levels of 35 dB(A) during the day and 30 dB(A) during the night; however, many hospitals exceed these recommended levels. Assessing post-occupancy sound levels enables hospital administrators and healthcare workers to identify whether interventions to improve sound levels are needed. Sound assessments were conducted at three healthcare facilities in both patient rooms and nursing stations, and we include information on facility characteristics. An Amprobe SM-20A Sound Level Meter was placed for a 24-hr period and recorded decibel levels every 8 min. These sound levels were averaged for each hour for reporting purposes. Averages as well as highest and lowest readings are reported for both daytime (8 a.m.-10 p.m.) and nighttime (10 p.m.-8 a.m.) for each facility. All three sites are considered urban and are classified with the highest complexity level (1a). Average daytime measurements for patient rooms and their corresponding nurses stations were as follows: Site A-63 dB(A)/56 dB(A), Site B-52 dB(A)/55 dB(A), and Site C-42 dB(A)/59 dB(A). Average nighttime measurements for patient rooms and nurses stations were Site A-62 dB(A)/55 dB(A), Site B-48 dB(A)/55 dB(A), and Site C-42 dB(A)/60 dB(A). Our findings, considered independently and collectively, showed that facilities in this study exceeded the WHO-recommended sound levels for patient rooms of 35 dB(A) during daytime and 30 dB(A) during nighttime. Research has reported negative patient outcomes, for example, decreased satisfaction, sleep disturbance, and higher incidence of rehospitalization in patients staying in areas with higher noise levels. © The Author(s) 2015.
Tutorial and Guidelines on Measurement of Sound Pressure Level in Voice and Speech.
Švec, Jan G; Granqvist, Svante
2018-03-15
Sound pressure level (SPL) measurement of voice and speech is often considered a trivial matter, but the measured levels are often reported incorrectly or incompletely, making them difficult to compare among various studies. This article aims at explaining the fundamental principles behind these measurements and providing guidelines to improve their accuracy and reproducibility. Basic information is put together from standards, technical, voice and speech literature, and practical experience of the authors and is explained for nontechnical readers. Variation of SPL with distance, sound level meters and their accuracy, frequency and time weightings, and background noise topics are reviewed. Several calibration procedures for SPL measurements are described for stand-mounted and head-mounted microphones. SPL of voice and speech should be reported together with the mouth-to-microphone distance so that the levels can be related to vocal power. Sound level measurement settings (i.e., frequency weighting and time weighting/averaging) should always be specified. Classified sound level meters should be used to assure measurement accuracy. Head-mounted microphones placed at the proximity of the mouth improve signal-to-noise ratio and can be taken advantage of for voice SPL measurements when calibrated. Background noise levels should be reported besides the sound levels of voice and speech.
Amplitude modulation of sound from wind turbines under various meteorological conditions.
Larsson, Conny; Öhlund, Olof
2014-01-01
Wind turbine (WT) sound annoys some people even though the sound levels are relatively low. This could be because of the amplitude modulated "swishing" characteristic of the turbine sound, which is not taken into account by standard procedures for measuring average sound levels. Studies of sound immission from WTs were conducted continually between 19 August 2011 and 19 August 2012 at two sites in Sweden. A method for quantifying the degree and strength of amplitude modulation (AM) is introduced here. The method reveals that AM at the immission points occur under specific meteorological conditions. For WT sound immission, the wind direction and sound speed gradient are crucial for the occurrence of AM. Interference between two or more WTs could probably enhance AM. The mechanisms by which WT sound is amplitude modulated are not fully understood.
Relations among pure-tone sound stimuli, neural activity, and the loudness sensation
NASA Technical Reports Server (NTRS)
Howes, W. L.
1972-01-01
Both the physiological and psychological responses to pure-tone sound stimuli are used to derive formulas which: (1) relate the loudness, loudness level, and sound-pressure level of pure tones; (2) apply continuously over most of the acoustic regime, including the loudness threshold; and (3) contain no undetermined coefficients. Some of the formulas are fundamental for calculating the loudness of any sound. Power-law formulas relating the pure-tone sound stimulus, neural activity, and loudness are derived from published data.
Popov, Vladimir V; Supin, Alexander Ya; Rozhnov, Viatcheslav V; Nechaev, Dmitry I; Sysueva, Evgenia V
2014-05-15
The influence of fatiguing sound level and duration on post-exposure temporary threshold shift (TTS) was investigated in two beluga whales (Delphinapterus leucas). The fatiguing sound was half-octave noise with a center frequency of 22.5 kHz. TTS was measured at a test frequency of 32 kHz. Thresholds were measured by recording rhythmic evoked potentials (the envelope following response) to a test series of short (eight cycles) tone pips with a pip rate of 1000 s(-1). TTS increased approximately proportionally to the dB measure of both sound pressure (sound pressure level, SPL) and duration of the fatiguing noise, as a product of these two variables. In particular, when the noise parameters varied in a manner that maintained the product of squared sound pressure and time (sound exposure level, SEL, which is equivalent to the overall noise energy) at a constant level, TTS was not constant. Keeping SEL constant, the highest TTS appeared at an intermediate ratio of SPL to sound duration and decreased at both higher and lower ratios. Multiplication (SPL multiplied by log duration) better described the experimental data than an equal-energy (equal SEL) model. The use of SEL as a sole universal metric may result in an implausible assessment of the impact of a fatiguing sound on hearing thresholds in odontocetes, including under-evaluation of potential risks. © 2014. Published by The Company of Biologists Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crecelius, E.A.; Fortman, T.J.; Kiesser, S.L.
1989-07-01
Concentrations of Cu, Pb, Zn, PAH's, TBT and FC bacteria were measured in surface sediment, sediment-trap, and water-column samples at two marinas in Puget Sound during summer of 1988. Levels of contaminants inside the marinas were compared with levels outside. TBT had greatest elevation in marina sediments compared to reference sediments. Few of sediments exceeded Puget Sound AET sediment quality values but most did exceed PSDDA screening levels for in-water disposal of dredged sediment. All marinas estimated to contribute less than one percent of total mass loading of Cu, Pb and Zn to main basin of Puget Sound. Contribution ofmore » TBT may be much more significant if antifouling paints are the major source for Puget Sound.« less
NASA Technical Reports Server (NTRS)
Lucas, Michael J.; Marcolini, Michael A.
1997-01-01
The Rotorcraft Noise Model (RNM) is an aircraft noise impact modeling computer program being developed for NASA-Langley Research Center which calculates sound levels at receiver positions either on a uniform grid or at specific defined locations. The basic computational model calculates a variety of metria. Acoustic properties of the noise source are defined by two sets of sound pressure hemispheres, each hemisphere being centered on a noise source of the aircraft. One set of sound hemispheres provides the broadband data in the form of one-third octave band sound levels. The other set of sound hemispheres provides narrowband data in the form of pure-tone sound pressure levels and phase. Noise contours on the ground are output graphically or in tabular format, and are suitable for inclusion in Environmental Impact Statements or Environmental Assessments.
Code of Federal Regulations, 2010 CFR
2010-07-01
... maximum A-weighted sound levels (FAST) for every retarder sound observed during the measurement period... performance as appropriate. (2) Data. The maximum A-weighted sound levels (FAST) for every car coupling impact...
Sound Pressure Levels Measured in a University Concert Band: A Risk of Noise-Induced Hearing Loss?
ERIC Educational Resources Information Center
Holland, Nicholas V., III
2008-01-01
Researchers have reported public school band directors as experiencing noise-induced hearing loss. Little research has focused on collegiate band directors and university student musicians. The present study measures the sound pressure levels generated within a university concert band and compares sound levels with the criteria set by the…
49 CFR 325.59 - Measurement procedure; stationary test.
Code of Federal Regulations, 2011 CFR
2011-10-01
... made of the sound level generated by a stationary motor vehicle as follows: (a) Park the motor vehicle... open throttle. Return the engine's speed to idle. (e) Observe the maximum reading on the sound level... this section until the first two maximum sound level readings that are within 2 dB(A) of each other are...
49 CFR 210.31 - Operation standards (stationary locomotives at 30 meters).
Code of Federal Regulations, 2011 CFR
2011-10-01
... prescribed in paragraph (a)(2) of this section, the A-weighted sound level reading in decibels shall be... A-weighted sound level reading in decibels that is observed during the 30-second period of time... test; (3) Date of test; and (4) The A-weighted sound level reading in decibels obtained during the...
Statistical Analysis for Subjective and Objective Evaluations of Dental Drill Sounds
Yamada, Tomomi; Kuwano, Sonoko; Ebisu, Shigeyuki; Hayashi, Mikako
2016-01-01
The sound produced by a dental air turbine handpiece (dental drill) can markedly influence the sound environment in a dental clinic. Indeed, many patients report that the sound of a dental drill elicits an unpleasant feeling. Although several manufacturers have attempted to reduce the sound pressure levels produced by dental drills during idling based on ISO 14457, the sound emitted by such drills under active drilling conditions may negatively influence the dental clinic sound environment. The physical metrics related to the unpleasant impressions associated with dental drill sounds have not been determined. In the present study, psychological measurements of dental drill sounds were conducted with the aim of facilitating improvement of the sound environment at dental clinics. Specifically, we examined the impressions elicited by the sounds of 12 types of dental drills in idling and drilling conditions using a semantic differential. The analysis revealed that the impressions of dental drill sounds varied considerably between idling and drilling conditions and among the examined drills. This finding suggests that measuring the sound of a dental drill in idling conditions alone may be insufficient for evaluating the effects of the sound. We related the results of the psychological evaluations to those of measurements of the physical metrics of equivalent continuous A-weighted sound pressure levels (LAeq) and sharpness. Factor analysis indicated that impressions of the dental drill sounds consisted of two factors: “metallic and unpleasant” and “powerful”. LAeq had a strong relationship with “powerful impression”, calculated sharpness was positively related to “metallic impression”, and “unpleasant impression” was predicted by the combination of both LAeq and calculated sharpness. The present analyses indicate that, in addition to a reduction in sound pressure level, refining the frequency components of dental drill sounds is important for creating a comfortable sound environment in dental clinics. PMID:27462903
Differences between Outdoor and Indoor Sound Levels for Open, Tilted, and Closed Windows
Locher, Barbara; Piquerez, André; Habermacher, Manuel; Ragettli, Martina; Cajochen, Christian; Vienneau, Danielle; Foraster, Maria; Müller, Uwe; Wunderli, Jean Marc
2018-01-01
Noise exposure prediction models for health effect studies normally estimate free field exposure levels outside. However, to assess the noise exposure inside dwellings, an estimate of indoor sound levels is necessary. To date, little field data is available about the difference between indoor and outdoor noise levels and factors affecting the damping of outside noise. This is a major cause of uncertainty in indoor noise exposure prediction and may lead to exposure misclassification in health assessments. This study aims to determine sound level differences between the indoors and the outdoors for different window positions and how this sound damping is related to building characteristics. For this purpose, measurements were carried out at home in a sample of 102 Swiss residents exposed to road traffic noise. Sound pressure level recordings were performed outdoors and indoors, in the living room and in the bedroom. Three scenarios—of open, tilted, and closed windows—were recorded for three minutes each. For each situation, data on additional parameters such as the orientation towards the source, floor, and room, as well as sound insulation characteristics were collected. On that basis, linear regression models were established. The median outdoor–indoor sound level differences were of 10 dB(A) for open, 16 dB(A) for tilted, and 28 dB(A) for closed windows. For open and tilted windows, the most relevant parameters affecting the outdoor–indoor differences were the position of the window, the type and volume of the room, and the age of the building. For closed windows, the relevant parameters were the sound level outside, the material of the window frame, the existence of window gaskets, and the number of windows. PMID:29346318
Differences between Outdoor and Indoor Sound Levels for Open, Tilted, and Closed Windows.
Locher, Barbara; Piquerez, André; Habermacher, Manuel; Ragettli, Martina; Röösli, Martin; Brink, Mark; Cajochen, Christian; Vienneau, Danielle; Foraster, Maria; Müller, Uwe; Wunderli, Jean Marc
2018-01-18
Noise exposure prediction models for health effect studies normally estimate free field exposure levels outside. However, to assess the noise exposure inside dwellings, an estimate of indoor sound levels is necessary. To date, little field data is available about the difference between indoor and outdoor noise levels and factors affecting the damping of outside noise. This is a major cause of uncertainty in indoor noise exposure prediction and may lead to exposure misclassification in health assessments. This study aims to determine sound level differences between the indoors and the outdoors for different window positions and how this sound damping is related to building characteristics. For this purpose, measurements were carried out at home in a sample of 102 Swiss residents exposed to road traffic noise. Sound pressure level recordings were performed outdoors and indoors, in the living room and in the bedroom. Three scenarios-of open, tilted, and closed windows-were recorded for three minutes each. For each situation, data on additional parameters such as the orientation towards the source, floor, and room, as well as sound insulation characteristics were collected. On that basis, linear regression models were established. The median outdoor-indoor sound level differences were of 10 dB(A) for open, 16 dB(A) for tilted, and 28 dB(A) for closed windows. For open and tilted windows, the most relevant parameters affecting the outdoor-indoor differences were the position of the window, the type and volume of the room, and the age of the building. For closed windows, the relevant parameters were the sound level outside, the material of the window frame, the existence of window gaskets, and the number of windows.
Spacecraft Internal Acoustic Environment Modeling
NASA Technical Reports Server (NTRS)
Chu, SShao-sheng R.; Allen, Christopher S.
2009-01-01
Acoustic modeling can be used to identify key noise sources, determine/analyze sub-allocated requirements, keep track of the accumulation of minor noise sources, and to predict vehicle noise levels at various stages in vehicle development, first with estimates of noise sources, later with experimental data. In FY09, the physical mockup developed in FY08, with interior geometric shape similar to Orion CM (Crew Module) IML (Interior Mode Line), was used to validate SEA (Statistical Energy Analysis) acoustic model development with realistic ventilation fan sources. The sound power levels of these sources were unknown a priori, as opposed to previous studies that RSS (Reference Sound Source) with known sound power level was used. The modeling results were evaluated based on comparisons to measurements of sound pressure levels over a wide frequency range, including the frequency range where SEA gives good results. Sound intensity measurement was performed over a rectangular-shaped grid system enclosing the ventilation fan source. Sound intensities were measured at the top, front, back, right, and left surfaces of the and system. Sound intensity at the bottom surface was not measured, but sound blocking material was placed tinder the bottom surface to reflect most of the incident sound energy back to the remaining measured surfaces. Integrating measured sound intensities over measured surfaces renders estimated sound power of the source. The reverberation time T6o of the mockup interior had been modified to match reverberation levels of ISS US Lab interior for speech frequency bands, i.e., 0.5k, 1k, 2k, 4 kHz, by attaching appropriately sized Thinsulate sound absorption material to the interior wall of the mockup. Sound absorption of Thinsulate was modeled in three methods: Sabine equation with measured mockup interior reverberation time T60, layup model based on past impedance tube testing, and layup model plus air absorption correction. The evaluation/validation was carried out by acquiring octave band microphone data simultaneously at ten fixed locations throughout the mockup. SPLs (Sound Pressure Levels) predicted by our SEA model match well with measurements for our CM mockup, with a more complicated shape. Additionally in FY09, background NC noise (Noise Criterion) simulation and MRT (Modified Rhyme Test) were developed and performed in the mockup to determine the maximum noise level in CM habitable volume for fair crew voice communications. Numerous demonstrations of simulated noise environment in the mockup and associated SIL (Speech Interference Level) via MRT were performed for various communities, including members from NASA and Orion prime-/sub-contractors. Also, a new HSIR (Human-Systems Integration Requirement) for limiting pre- and post-landing SIL was proposed.
Delgutte, Bertrand
2015-01-01
At lower levels of sensory processing, the representation of a stimulus feature in the response of a neural population can vary in complex ways across different stimulus intensities, potentially changing the amount of feature-relevant information in the response. How higher-level neural circuits could implement feature decoding computations that compensate for these intensity-dependent variations remains unclear. Here we focused on neurons in the inferior colliculus (IC) of unanesthetized rabbits, whose firing rates are sensitive to both the azimuthal position of a sound source and its sound level. We found that the azimuth tuning curves of an IC neuron at different sound levels tend to be linear transformations of each other. These transformations could either increase or decrease the mutual information between source azimuth and spike count with increasing level for individual neurons, yet population azimuthal information remained constant across the absolute sound levels tested (35, 50, and 65 dB SPL), as inferred from the performance of a maximum-likelihood neural population decoder. We harnessed evidence of level-dependent linear transformations to reduce the number of free parameters in the creation of an accurate cross-level population decoder of azimuth. Interestingly, this decoder predicts monotonic azimuth tuning curves, broadly sensitive to contralateral azimuths, in neurons at higher levels in the auditory pathway. PMID:26490292
NASA Technical Reports Server (NTRS)
Gray, R. B.; Pierce, G. A.
1972-01-01
Wind tunnel tests were performed on two oscillating two-dimensional lifting surfaces. The first of these models had an NACA 0012 airfoil section while the second simulated the classical flat plate. Both of these models had a mean angle of attack of 12 degrees while being oscillated in pitch about their midchord with a double amplitude of 6 degrees. Wake surveys of sound pressure level were made over a frequency range from 16 to 32 Hz and at various free stream velocities up to 100 ft/sec. The sound pressure level spectrum indicated significant peaks in sound intensity at the oscillation frequency and its first harmonic near the wake of both models. From a comparison of these data with that of a sound level meter, it is concluded that most of the sound intensity is contained within these peaks and no appreciable peaks occur at higher harmonics. It is concluded that within the wake the sound intensity is largely pseudosound while at one chord length outside the wake, it is largely true vortex sound. For both the airfoil and flat plate the peaks appear to be more strongly dependent upon the airspeed than on the oscillation frequency. Therefore reduced frequency does not appear to be a significant parameter in the generation of wake sound intensity.
Kastelein, Ronald A; van der Heul, Sander; Verboom, Willem C; Triesscheijn, Rob J V; Jennings, Nancy V
2006-02-01
To prevent grounding of ships and collisions between ships in shallow coastal waters, an underwater data collection and communication network (ACME) using underwater sounds to encode and transmit data is currently under development. Marine mammals might be affected by ACME sounds since they may use sound of a similar frequency (around 12 kHz) for communication, orientation, and prey location. If marine mammals tend to avoid the vicinity of the acoustic transmitters, they may be kept away from ecologically important areas by ACME sounds. One marine mammal species that may be affected in the North Sea is the harbour seal (Phoca vitulina). No information is available on the effects of ACME-like sounds on harbour seals, so this study was carried out as part of an environmental impact assessment program. Nine captive harbour seals were subjected to four sound types, three of which may be used in the underwater acoustic data communication network. The effect of each sound was judged by comparing the animals' location in a pool during test periods to that during baseline periods, during which no sound was produced. Each of the four sounds could be made into a deterrent by increasing its amplitude. The seals reacted by swimming away from the sound source. The sound pressure level (SPL) at the acoustic discomfort threshold was established for each of the four sounds. The acoustic discomfort threshold is defined as the boundary between the areas that the animals generally occupied during the transmission of the sounds and the areas that they generally did not enter during transmission. The SPLs at the acoustic discomfort thresholds were similar for each of the sounds (107 dB re 1 microPa). Based on this discomfort threshold SPL, discomfort zones at sea for several source levels (130-180 dB re 1 microPa) of the sounds were calculated, using a guideline sound propagation model for shallow water. The discomfort zone is defined as the area around a sound source that harbour seals are expected to avoid. The definition of the discomfort zone is based on behavioural discomfort, and does not necessarily coincide with the physical discomfort zone. Based on these results, source levels can be selected that have an acceptable effect on harbour seals in particular areas. The discomfort zone of a communication sound depends on the sound, the source level, and the propagation characteristics of the area in which the sound system is operational. The source level of the communication system should be adapted to each area (taking into account the width of a sea arm, the local sound propagation, and the importance of an area to the affected species). The discomfort zone should not coincide with ecologically important areas (for instance resting, breeding, suckling, and feeding areas), or routes between these areas.
Investigation of Noise Field and Velocity Profiles of an Afterburning Engine
NASA Technical Reports Server (NTRS)
North, Warren J.; Callaghan, E. E.; Lanzo, C. D.
1954-01-01
Sound pressure levels, frequency spectrum, and jet velocity profiles are presented for an engine-afterburner combination at various values of afterburner fuel - air ratio. At the high fuel-air ratios, severe low-frequency resonance was encountered which represented more than half the total energy in the sound spectrum. At similar thrust conditions, lower sound pressure levels were obtained from a current fighter air craft with a different afterburner configuration. The lower sound pressure levels are attributed to resonance-free afterburner operation and thereby indicate the importance of acoustic considerations in afterburner design.
Effects of Sound on the Behavior of Wild, Unrestrained Fish Schools.
Roberts, Louise; Cheesman, Samuel; Hawkins, Anthony D
2016-01-01
To assess and manage the impact of man-made sounds on fish, we need information on how behavior is affected. Here, wild unrestrained pelagic fish schools were observed under quiet conditions using sonar. Fish were exposed to synthetic piling sounds at different levels using custom-built sound projectors, and behavioral changes were examined. In some cases, the depth of schools changed after noise playback; full dispersal of schools was also evident. The methods we developed for examining the behavior of unrestrained fish to sound exposure have proved successful and may allow further testing of the relationship between responsiveness and sound level.
The influence of sea ice, wind speed and marine mammals on Southern Ocean ambient sound.
Menze, Sebastian; Zitterbart, Daniel P; van Opzeeland, Ilse; Boebel, Olaf
2017-01-01
This paper describes the natural variability of ambient sound in the Southern Ocean, an acoustically pristine marine mammal habitat. Over a 3-year period, two autonomous recorders were moored along the Greenwich meridian to collect underwater passive acoustic data. Ambient sound levels were strongly affected by the annual variation of the sea-ice cover, which decouples local wind speed and sound levels during austral winter. With increasing sea-ice concentration, area and thickness, sound levels decreased while the contribution of distant sources increased. Marine mammal sounds formed a substantial part of the overall acoustic environment, comprising calls produced by Antarctic blue whales ( Balaenoptera musculus intermedia ), fin whales ( Balaenoptera physalus ), Antarctic minke whales ( Balaenoptera bonaerensis ) and leopard seals ( Hydrurga leptonyx ). The combined sound energy of a group or population vocalizing during extended periods contributed species-specific peaks to the ambient sound spectra. The temporal and spatial variation in the contribution of marine mammals to ambient sound suggests annual patterns in migration and behaviour. The Antarctic blue and fin whale contributions were loudest in austral autumn, whereas the Antarctic minke whale contribution was loudest during austral winter and repeatedly showed a diel pattern that coincided with the diel vertical migration of zooplankton.
The influence of sea ice, wind speed and marine mammals on Southern Ocean ambient sound
NASA Astrophysics Data System (ADS)
Menze, Sebastian; Zitterbart, Daniel P.; van Opzeeland, Ilse; Boebel, Olaf
2017-01-01
This paper describes the natural variability of ambient sound in the Southern Ocean, an acoustically pristine marine mammal habitat. Over a 3-year period, two autonomous recorders were moored along the Greenwich meridian to collect underwater passive acoustic data. Ambient sound levels were strongly affected by the annual variation of the sea-ice cover, which decouples local wind speed and sound levels during austral winter. With increasing sea-ice concentration, area and thickness, sound levels decreased while the contribution of distant sources increased. Marine mammal sounds formed a substantial part of the overall acoustic environment, comprising calls produced by Antarctic blue whales (Balaenoptera musculus intermedia), fin whales (Balaenoptera physalus), Antarctic minke whales (Balaenoptera bonaerensis) and leopard seals (Hydrurga leptonyx). The combined sound energy of a group or population vocalizing during extended periods contributed species-specific peaks to the ambient sound spectra. The temporal and spatial variation in the contribution of marine mammals to ambient sound suggests annual patterns in migration and behaviour. The Antarctic blue and fin whale contributions were loudest in austral autumn, whereas the Antarctic minke whale contribution was loudest during austral winter and repeatedly showed a diel pattern that coincided with the diel vertical migration of zooplankton.
ERIC Educational Resources Information Center
California State Dept. of Education, Sacramento.
California has conducted on-site sound surveys of 36 different schools to determine the degree of noise, and thus disturbance, within the learning environment. This report provides the methodology and results of the survey, including descriptive charts and graphs illustrating typical desirable and undesirable sound levels. Results are presented…
Code of Federal Regulations, 2010 CFR
2010-07-01
... 85 dBA, or equivalently a dose of 50%, integrating all sound levels from 80 dBA to at least 130 dBA... Protection Level. A TWA8 of 105 dBA, or equivalently, a dose of 800% of that permitted by the standard, integrating all sound levels from 90 dBA to at least 140 dBA. Exchange rate. The amount of increase in sound...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 85 dBA, or equivalently a dose of 50%, integrating all sound levels from 80 dBA to at least 130 dBA... Protection Level. A TWA8 of 105 dBA, or equivalently, a dose of 800% of that permitted by the standard, integrating all sound levels from 90 dBA to at least 140 dBA. Exchange rate. The amount of increase in sound...
40 CFR 201.11 - Standard for locomotive operation under stationary conditions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... completed on or before December 31, 1979, which produces A-weighted sound levels in excess of 93 dB at any..., 1979, which produces A-weighted sound levels in excess of 87 dB at any throttle setting except idle... December 31, 1979, which produces A-weighted sound levels in excess of 87 dB at any throttle setting except...
40 CFR 201.11 - Standard for locomotive operation under stationary conditions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... completed on or before December 31, 1979, which produces A-weighted sound levels in excess of 93 dB at any..., 1979, which produces A-weighted sound levels in excess of 87 dB at any throttle setting except idle... December 31, 1979, which produces A-weighted sound levels in excess of 87 dB at any throttle setting except...
49 CFR 325.73 - Microphone distance correction factors. 1
Code of Federal Regulations, 2011 CFR
2011-10-01
... factors. 1 1 Table 1, in § 325.7 is a tabulation of the maximum allowable sound level readings taking into... target point is other than 50 feet (15.2 m), the maximum observed sound level reading generated by the... observed sound level readings generated by the motor vehicle in accordance with § 325.59 of this part shall...
49 CFR 325.73 - Microphone distance correction factors. 1
Code of Federal Regulations, 2010 CFR
2010-10-01
... factors. 1 1 Table 1, in § 325.7 is a tabulation of the maximum allowable sound level readings taking into... target point is other than 50 feet (15.2 m), the maximum observed sound level reading generated by the... observed sound level readings generated by the motor vehicle in accordance with § 325.59 of this part shall...
The annoyance of impulsive helicopter noise
NASA Technical Reports Server (NTRS)
Karamcheti, K.
1981-01-01
A total of 96 impulsive and non-impulsive sounds were rated for annoyance by 10 subjects. The signals had the same amplitude spectrum with a maximum frequency of 4.75 kHz. By changing the phase of the spectral components different levels of impulsivity were obtained. The signals had coefficients of impulsivity of 10,8, 7,9, and -0.2 respectively. Further, signals had intensity levels 89 and 95 dBA, pulse repetition rates 10 and 20 Hz, and half the signals had pink noise added at a level 12 dBA lower than the level of the sound. The significant results were: The four females and six male subjects rated the impulsive sounds respectively 3.7 dB less annoying and 2.6 dB more annoying than the non-impulsive sounds. Overall, impulsivity had no effect. The hish pulse repetition rate increased annoyance by 2.2 dB. Addition of pink noise increased annoyance of the non-impulsive sounds 1.2 dB, but decreased the annoyance of the impulsive sounds 0.5 dB.
Sound level-dependent growth of N1m amplitude with low and high-frequency tones.
Soeta, Yoshiharu; Nakagawa, Seiji
2009-04-22
The aim of this study was to determine whether the amplitude and/or latency of the N1m deflection of auditory-evoked magnetic fields are influenced by the level and frequency of sound. The results indicated that the amplitude of the N1m increased with sound level. The growth in amplitude with increasing sound level was almost constant with low frequencies (250-1000 Hz); however, this growth decreased with high frequencies (>2000 Hz). The behavior of the amplitude may reflect a difference in the increase in the activation of the peripheral and/or central auditory systems.
What the Toadfish Ear Tells the Toadfish Brain About Sound.
Edds-Walton, Peggy L
2016-01-01
Of the three, paired otolithic endorgans in the ear of teleost fishes, the saccule is the one most often demonstrated to have a major role in encoding frequencies of biologically relevant sounds. The toadfish saccule also encodes sound level and sound source direction in the phase-locked activity conveyed via auditory afferents to nuclei of the ipsilateral octaval column in the medulla. Although paired auditory receptors are present in teleost fishes, binaural processes were believed to be unimportant due to the speed of sound in water and the acoustic transparency of the tissues in water. In contrast, there are behavioral and anatomical data that support binaural processing in fishes. Studies in the toadfish combined anatomical tract-tracing and physiological recordings from identified sites along the ascending auditory pathway to document response characteristics at each level. Binaural computations in the medulla and midbrain sharpen the directional information provided by the saccule. Furthermore, physiological studies in the central nervous system indicated that encoding frequency, sound level, temporal pattern, and sound source direction are important components of what the toadfish ear tells the toadfish brain about sound.
Parra, Johanna; de Suremain, Aurelie; Berne Audeoud, Frederique; Ego, Anne; Debillon, Thierry
2017-12-01
This study measured sound levels in a 2008 built French neonatal intensive care unit (NICU) and compared them to the 2007 American Academy of Pediatrics (AAP) recommendations. The ultimate aim was to identify factors that could influence noise levels. The study measured sound in 17 single or double rooms in the NICU. Two dosimeters were installed in each room, one inside and one outside the incubators, and these conducted measurements over a 24-hour period. The noise metrics measured were the equivalent continuous sound level (L eq ), the maximum noise level (L max ) and the noise level exceeded for 10% of the measurement period (L 10 ). The mean L eq , L 10 and L max were 60.4, 62.1 and 89.1 decibels (dBA), which exceeded the recommended levels of 45, 50 and 65 dBA (p < 0.001), respectively. The L eq inside the incubator was significantly higher than in the room (+8 dBA, p < 0.001). None of the newborns' characteristics, the environment or medical care was correlated to an increased noise level, except for a postconceptional age below 32 weeks. The sound levels significantly exceeded the AAP recommendations, particularly inside incubators. A multipronged strategy is required to improve the sound environment and protect the neonates' sensory development. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.
MP3 player listening sound pressure levels among 10 to 17 year old students.
Keith, Stephen E; Michaud, David S; Feder, Katya; Haider, Ifaz; Marro, Leonora; Thompson, Emma; Marcoux, Andre M
2011-11-01
Using a manikin, equivalent free-field sound pressure level measurements were made from the portable digital audio players of 219 subjects, aged 10 to 17 years (93 males) at their typical and "worst-case" volume levels. Measurements were made in different classrooms with background sound pressure levels between 40 and 52 dBA. After correction for the transfer function of the ear, the median equivalent free field sound pressure levels and interquartile ranges (IQR) at typical and worst-case volume settings were 68 dBA (IQR = 15) and 76 dBA (IQR = 19), respectively. Self-reported mean daily use ranged from 0.014 to 12 h. When typical sound pressure levels were considered in combination with the average daily duration of use, the median noise exposure level, Lex, was 56 dBA (IQR = 18) and 3.2% of subjects were estimated to exceed the most protective occupational noise exposure level limit in Canada, i.e., 85 dBA Lex. Under worst-case listening conditions, 77.6% of the sample was estimated to listen to their device at combinations of sound pressure levels and average daily durations for which there is no known risk of permanent noise-induced hearing loss, i.e., ≤ 75 dBA Lex. Sources and magnitudes of measurement uncertainties are also discussed.
41 CFR 50-204.10 - Occupational noise exposure.
Code of Federal Regulations, 2010 CFR
2010-07-01
... determined as follows: EC21OC91.015 Equivalent sound level contours. Octave band sound pressure levels may be... level dBA slow response 8 90 6 92 4 95 3 97 2 100 11/2 102 1 105 1/2 110 1/4 or less 115 1 When the... not exceed 140 dB peak sound pressure level. [34 FR 7946, May 20, 1969, as amended at 35 FR 1015, Jan...
41 CFR 50-204.10 - Occupational noise exposure.
Code of Federal Regulations, 2011 CFR
2011-07-01
... determined as follows: EC21OC91.015 Equivalent sound level contours. Octave band sound pressure levels may be... level dBA slow response 8 90 6 92 4 95 3 97 2 100 11/2 102 1 105 1/2 110 1/4 or less 115 1 When the... not exceed 140 dB peak sound pressure level. [34 FR 7946, May 20, 1969, as amended at 35 FR 1015, Jan...
Sound Levels and Risk Perceptions of Music Students During Classes.
Rodrigues, Matilde A; Amorim, Marta; Silva, Manuela V; Neves, Paula; Sousa, Aida; Inácio, Octávio
2015-01-01
It is well recognized that professional musicians are at risk of hearing damage due to the exposure to high sound pressure levels during music playing. However, it is important to recognize that the musicians' exposure may start early in the course of their training as students in the classroom and at home. Studies regarding sound exposure of music students and their hearing disorders are scarce and do not take into account important influencing variables. Therefore, this study aimed to describe sound level exposures of music students at different music styles, classes, and according to the instrument played. Further, this investigation attempted to analyze the perceptions of students in relation to exposure to loud music and consequent health risks, as well as to characterize preventive behaviors. The results showed that music students are exposed to high sound levels in the course of their academic activity. This exposure is potentiated by practice outside the school and other external activities. Differences were found between music style, instruments, and classes. Tinnitus, hyperacusis, diplacusis, and sound distortion were reported by the students. However, students were not entirely aware of the health risks related to exposure to high sound pressure levels. These findings reflect the importance of starting intervention in relation to noise risk reduction at an early stage, when musicians are commencing their activity as students.
Underwater sound of rigid-hulled inflatable boats.
Erbe, Christine; Liong, Syafrin; Koessler, Matthew Walter; Duncan, Alec J; Gourlay, Tim
2016-06-01
Underwater sound of rigid-hulled inflatable boats was recorded 142 times in total, over 3 sites: 2 in southern British Columbia, Canada, and 1 off Western Australia. Underwater sound peaked between 70 and 400 Hz, exhibiting strong tones in this frequency range related to engine and propeller rotation. Sound propagation models were applied to compute monopole source levels, with the source assumed 1 m below the sea surface. Broadband source levels (10-48 000 Hz) increased from 134 to 171 dB re 1 μPa @ 1 m with speed from 3 to 16 m/s (10-56 km/h). Source power spectral density percentile levels and 1/3 octave band levels are given for use in predictive modeling of underwater sound of these boats as part of environmental impact assessments.
Graded behavioral responses and habituation to sound in the common cuttlefish Sepia officinalis.
Samson, Julia E; Mooney, T Aran; Gussekloo, Sander W S; Hanlon, Roger T
2014-12-15
Sound is a widely available and vital cue in aquatic environments, yet most bioacoustic research has focused on marine vertebrates, leaving sound detection in invertebrates poorly understood. Cephalopods are an ecologically key taxon that likely use sound and may be impacted by increasing anthropogenic ocean noise, but little is known regarding their behavioral responses or adaptations to sound stimuli. These experiments identify the acoustic range and levels that elicit a wide range of secondary defense behaviors such as inking, jetting and rapid coloration change. Secondarily, it was found that cuttlefish habituate to certain sound stimuli. The present study examined the behavioral responses of 22 cuttlefish (Sepia officinalis) to pure-tone pips ranging from 80 to 1000 Hz with sound pressure levels of 85-188 dB re. 1 μPa rms and particle accelerations of 0-17.1 m s(-2). Cuttlefish escape responses (inking, jetting) were observed between frequencies of 80 and 300 Hz and at sound levels above 140 dB re. 1 μPa rms and 0.01 m s(-2) (0.74 m s(-2) for inking responses). Body patterning changes and fin movements were observed at all frequencies and sound levels. Response intensity was dependent upon stimulus amplitude and frequency, suggesting that cuttlefish also possess loudness perception with a maximum sensitivity around 150 Hz. Cuttlefish habituated to repeated 200 Hz tone pips, at two sound intensities. Total response inhibition was not reached, however, and a basal response remained present in most animals. The graded responses provide a loudness sensitivity curve and suggest an ecological function for sound use in cephalopods. © 2014. Published by The Company of Biologists Ltd.
Knight, Lisa; Ladich, Friedrich
2014-11-15
Thorny catfishes produce stridulation (SR) sounds using their pectoral fins and drumming (DR) sounds via a swimbladder mechanism in distress situations when hand held in water and in air. It has been argued that SR and DR sounds are aimed at different receivers (predators) in different media. The aim of this study was to analyse and compare sounds emitted in both air and water in order to test different hypotheses on the functional significance of distress sounds. Five representatives of the family Doradidae were investigated. Fish were hand held and sounds emitted in air and underwater were recorded (number of sounds, sound duration, dominant and fundamental frequency, sound pressure level and peak-to-peak amplitudes). All species produced SR sounds in both media, but DR sounds could not be recorded in air for two species. Differences in sound characteristics between media were small and mainly limited to spectral differences in SR. The number of sounds emitted decreased over time, whereas the duration of SR sounds increased. The dominant frequency of SR and the fundamental frequency of DR decreased and sound pressure level of SR increased with body size across species. The hypothesis that catfish produce more SR sounds in air and more DR sounds in water as a result of different predation pressure (birds versus fish) could not be confirmed. It is assumed that SR sounds serve as distress sounds in both media, whereas DR sounds might primarily be used as intraspecific communication signals in water in species possessing both mechanisms. © 2014. Published by The Company of Biologists Ltd.
An investigation of the sound field above the audience in large lecture halls with a scale model.
Kahn, D W; Tichy, J
1986-09-01
Measurements of steady-state sound pressure levels above the audience in large lecture halls show that the classical equation for predicting the sound pressure level is not accurate. The direct field above the seats was measured on a 1:10 scale model and was found to be dependent on the incidence angle and direction of sound propagation across the audience. The reverberant field above the seats in the model was calculated by subtracting the direct field from the measured total field and was found to be dependent on the magnitude and particularly on the placement of absorption. The decrease of sound pressure level versus distance in the total field depends on the angle (controlled by absorption placement) at which the strong reflections are incident upon the audience area. Sound pressure level decreases at a fairly constant rate with distance from the sound source in both the direct and reverberant field, and the decrease rate depends strongly on the absorption placement. The lowest rate of decay occurs when the side walls are absorptive, and both the ceiling and rear wall are reflective. These consequences are discussed with respect to prediction of speech intelligibility.
Non-auditory health effects among air force crew chiefs exposed to high level sound.
Jensen, Anker; Lund, Søren Peter; Lücke, Thorsten Høgh; Clausen, Ole Voldum; Svendsen, Jørgen Torp
2009-01-01
The possibility of non-auditory health effects in connection with occupational exposure to high level sound is supposed by some researchers, but is still debated. Crew chiefs on airfields are exposed to high-level aircraft sound when working close to aircraft with running engines. We compared their health status with a similar control group who were not subject to this specific sound exposure. Health records of 42 crew chiefs were compared to health records of 42 aircraft mechanics and 17 former crew chiefs. The specific sound exposure of crew chiefs was assessed. The number of reported disease cases was generally small, but generally slightly higher among mechanics than among crew chiefs. Diseases of the ear were more frequent among crew chiefs (not significant). Former crew chiefs reported fewer diseases of the ear and more airways infections (both significant). The sound exposure during launch was up to 144 dB (peak) and 124 dB (L(eq) ), but for limited time. The study did not reveal a higher disease frequency in general among crew chiefs. However, it did reveal a tendency to ear diseases, possibly due to their exposure to high-level sound.
Short-Range Acoustic Propagation Using Mobile Transmitters Under Arctic Ice Cover
2017-09-01
predict the surface water/ice scattering and absorptive effects on transmitted sound . In addition, sound speed variability by range (usually...receivers at ranges out to 10 kilometers. Sound speed profile data was also measured on site. Transmission loss models were created as a baseline at the...received sound level (on the level of 30 to 40 decibels) at the same range and depth but different directions. 14. SUBJECT TERMS Arctic, Beaufort Sea
75 FR 39915 - Marine Mammals; File No. 15483
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-13
... whales adjust their bearing to avoid received sound pressure levels greater than 120 dB, which would... marine mammals may be taken by Level B harassment as researchers attempt to provoke an avoidance response through sound transmission into their environment. The sound source consists of a transmitter and...
40 CFR 205.54-2 - Sound data acquisition system.
Code of Federal Regulations, 2010 CFR
2010-07-01
... meets the “fast” dynamic requirement of a precision sound level meter indicating meter system for the... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Sound data acquisition system. 205.54... data acquisition system. (a) Systems employing tape recorders and graphic level recorders may be...
An Analysis of Sound Exposure in a University Music Rehearsal
ERIC Educational Resources Information Center
Farmer, Joe; Thrasher, Michael; Fumo, Nelson
2014-01-01
Exposure to high sound levels may lead to a variety of hearing abnormalities, including Noise-Induced Hearing Loss (NIHL). Pre-professional university music majors may experience frequent exposure to elevated sound levels, and this may have implications on their future career prospects (Jansen, Helleman, Dreschler & de Laat, 2009). Studies…
Sapienza, C M; Crandell, C C; Curtis, B
1999-09-01
Voice problems are a frequent difficulty that teachers experience. Common complaints by teachers include vocal fatigue and hoarseness. One possible explanation for these symptoms is prolonged elevations in vocal loudness within the classroom. This investigation examined the effectiveness of sound-field frequency modulation (FM) amplification on reducing the sound pressure level (SPL) of the teacher's voice during classroom instruction. Specifically, SPL was examined during speech produced in a classroom lecture by 10 teachers with and without the use of sound-field amplification. Results indicated a significant 2.42-dB decrease in SPL with the use of sound-field FM amplification. These data support the use of sound-field amplification in the vocal hygiene regimen recommended to teachers by speech-language pathologists.
33 CFR 67.10-40 - Sound signals authorized for use prior to January 1, 1973.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., and 67.10-10, if the sound signal has a minimum sound pressure level as specified in Table A of... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Sound signals authorized for use... STRUCTURES General Requirements for Sound signals § 67.10-40 Sound signals authorized for use prior to...
Accuracy of assessing the level of impulse sound from distant sources.
Wszołek, Tadeusz; Kłaczyński, Maciej
2007-01-01
Impulse sound events are characterised by ultra high pressures and low frequencies. Lower frequency sounds are generally less attenuated over a given distance in the atmosphere than higher frequencies. Thus, impulse sounds can be heard over greater distances and will be more affected by the environment. To calculate a long-term average immission level it is necessary to apply weighting factors like the probability of the occurrence of each weather condition during the relevant time period. This means that when measuring impulse noise at a long distance it is necessary to follow environmental parameters in many points along the way sound travels and also to have a database of sound transfer functions in the long term. The paper analyses the uncertainty of immission measurement results of impulse sound from cladding and destroying explosive materials. The influence of environmental conditions on the way sound travels is the focus of this paper.
Minimizing noise in fiberglass aquaculture tanks: Noise reduction potential of various retrofits
Davidson, J.; Frankel, A.S.; Ellison, W.T.; Summerfelt, S.; Popper, A.N.; Mazik, P.; Bebak, J.
2007-01-01
Equipment used in intensive aquaculture systems, such as pumps and blowers can produce underwater sound levels and frequencies within the range of fish hearing. The impacts of underwater noise on fish are not well known, but limited research suggests that subjecting fish to noise could result in impairment of the auditory system, reduced growth rates, and increased stress. Consequently, reducing sound in fish tanks could result in advantages for cultured species and increased productivity for the aquaculture industry. The objective of this study was to evaluate the noise reduction potential of various retrofits to fiberglass fish culture tanks. The following structural changes were applied to tanks to reduce underwater noise: (1) inlet piping was suspended to avoid contact with the tank, (2) effluent piping was disconnected from a common drain line, (3) effluent piping was insulated beneath tanks, and (4) tanks were elevated on cement blocks and seated on insulated padding. Four combinations of the aforementioned structural changes were evaluated in duplicate and two tanks were left unchanged as controls. Control tanks had sound levels of 120.6 dB re 1 ??Pa. Each retrofit contributed to a reduction of underwater sound. As structural changes were combined, a cumulative reduction in sound level was observed. Tanks designed with a combination of retrofits had sound levels of 108.6 dB re 1 ??Pa, a four-fold reduction in sound pressure level. Sound frequency spectra indicated that the greatest sound reductions occurred between 2 and 100 Hz and demonstrated that nearby pumps and blowers created tonal frequencies that were transmitted into the tanks. The tank modifications used during this study were simple and inexpensive and could be applied to existing systems or considered when designing aquaculture facilities. ?? 2007 Elsevier B.V. All rights reserved.
Hermannsen, Line; Beedholm, Kristian
2017-01-01
Acoustic harassment devices (AHD) or ‘seal scarers’ are used extensively, not only to deter seals from fisheries, but also as mitigation tools to deter marine mammals from potentially harmful sound sources, such as offshore pile driving. To test the effectiveness of AHDs, we conducted two studies with similar experimental set-ups on two key species: harbour porpoises and harbour seals. We exposed animals to 500 ms tone bursts at 12 kHz simulating that of an AHD (Lofitech), but with reduced output levels (source peak-to-peak level of 165 dB re 1 µPa). Animals were localized with a theodolite before, during and after sound exposures. In total, 12 sound exposures were conducted to porpoises and 13 exposures to seals. Porpoises were found to exhibit avoidance reactions out to ranges of 525 m from the sound source. Contrary to this, seal observations increased during sound exposure within 100 m of the loudspeaker. We thereby demonstrate that porpoises and seals respond very differently to AHD sounds. This has important implications for application of AHDs in multi-species habitats, as sound levels required to deter less sensitive species (seals) can lead to excessive and unwanted large deterrence ranges on more sensitive species (porpoises). PMID:28791155
The influence of sea ice, wind speed and marine mammals on Southern Ocean ambient sound
van Opzeeland, Ilse; Boebel, Olaf
2017-01-01
This paper describes the natural variability of ambient sound in the Southern Ocean, an acoustically pristine marine mammal habitat. Over a 3-year period, two autonomous recorders were moored along the Greenwich meridian to collect underwater passive acoustic data. Ambient sound levels were strongly affected by the annual variation of the sea-ice cover, which decouples local wind speed and sound levels during austral winter. With increasing sea-ice concentration, area and thickness, sound levels decreased while the contribution of distant sources increased. Marine mammal sounds formed a substantial part of the overall acoustic environment, comprising calls produced by Antarctic blue whales (Balaenoptera musculus intermedia), fin whales (Balaenoptera physalus), Antarctic minke whales (Balaenoptera bonaerensis) and leopard seals (Hydrurga leptonyx). The combined sound energy of a group or population vocalizing during extended periods contributed species-specific peaks to the ambient sound spectra. The temporal and spatial variation in the contribution of marine mammals to ambient sound suggests annual patterns in migration and behaviour. The Antarctic blue and fin whale contributions were loudest in austral autumn, whereas the Antarctic minke whale contribution was loudest during austral winter and repeatedly showed a diel pattern that coincided with the diel vertical migration of zooplankton. PMID:28280544
Why Do People Like Loud Sound? A Qualitative Study.
Welch, David; Fremaux, Guy
2017-08-11
Many people choose to expose themselves to potentially dangerous sounds such as loud music, either via speakers, personal audio systems, or at clubs. The Conditioning, Adaptation and Acculturation to Loud Music (CAALM) Model has proposed a theoretical basis for this behaviour. To compare the model to data, we interviewed a group of people who were either regular nightclub-goers or who controlled the sound levels in nightclubs (bar managers, musicians, DJs, and sound engineers) about loud sound. Results showed four main themes relating to the enjoyment of loud sound: arousal/excitement, facilitation of socialisation, masking of both external sound and unwanted thoughts, and an emphasis and enhancement of personal identity. Furthermore, an interesting incidental finding was that sound levels appeared to increase gradually over the course of the evening until they plateaued at approximately 97 dBA Leq around midnight. Consideration of the data generated by the analysis revealed a complex of influential factors that support people in wanting exposure to loud sound. Findings were considered in terms of the CAALM Model and could be explained in terms of its principles. From a health promotion perspective, the Social Ecological Model was applied to consider how the themes identified might influence behaviour. They were shown to influence people on multiple levels, providing a powerful system which health promotion approaches struggle to address.
NASA Astrophysics Data System (ADS)
Moore, Brian C. J.
Psychoacoustics
Salomons, Erik M; Janssen, Sabine A
2011-06-01
In environmental noise control one commonly employs the A-weighted sound level as an approximate measure of the effect of noise on people. A measure that is more closely related to direct human perception of noise is the loudness level. At constant A-weighted sound level, the loudness level of a noise signal varies considerably with the shape of the frequency spectrum of the noise signal. In particular the bandwidth of the spectrum has a large effect on the loudness level, due to the effect of critical bands in the human hearing system. The low-frequency content of the spectrum also has an effect on the loudness level. In this note the relation between loudness level and A-weighted sound level is analyzed for various environmental noise spectra, including spectra of traffic noise, aircraft noise, and industrial noise. From loudness levels calculated for these environmental noise spectra, diagrams are constructed that show the relation between loudness level, A-weighted sound level, and shape of the spectrum. The diagrams show that the upper limits of the loudness level for broadband environmental noise spectra are about 20 to 40 phon higher than the lower limits for narrowband spectra, which correspond to the loudness levels of pure tones. The diagrams are useful for assessing limitations and potential improvements of environmental noise control methods and policy based on A-weighted sound levels.
NASA Technical Reports Server (NTRS)
Koch, L. Danielle
2012-01-01
Fan inflow distortion tone noise has been studied computationally and experimentally. Data from two experiments in the NASA Glenn Advanced Noise Control Fan rig have been used to validate acoustic predictions. The inflow to the fan was distorted by cylindrical rods inserted radially into the inlet duct one rotor chord length upstream of the fan. The rods were arranged in both symmetric and asymmetric circumferential patterns. In-duct and farfield sound pressure level measurements were recorded. It was discovered that for positive circumferential modes, measured circumferential mode sound power levels in the exhaust duct were greater than those in the inlet duct and for negative circumferential modes, measured total circumferential mode sound power levels in the exhaust were less than those in the inlet. Predicted trends in overall sound power level were proven to be useful in identifying circumferentially asymmetric distortion patterns that reduce overall inlet distortion tone noise, as compared to symmetric arrangements of rods. Detailed comparisons between the measured and predicted radial mode sound power in the inlet and exhaust duct indicate limitations of the theory.
Christensen, Christian Bech; Christensen-Dalsgaard, Jakob; Brandt, Christian; Madsen, Peter Teglberg
2012-01-15
Snakes lack both an outer ear and a tympanic middle ear, which in most tetrapods provide impedance matching between the air and inner ear fluids and hence improve pressure hearing in air. Snakes would therefore be expected to have very poor pressure hearing and generally be insensitive to airborne sound, whereas the connection of the middle ear bone to the jaw bones in snakes should confer acute sensitivity to substrate vibrations. Some studies have nevertheless claimed that snakes are quite sensitive to both vibration and sound pressure. Here we test the two hypotheses that: (1) snakes are sensitive to sound pressure and (2) snakes are sensitive to vibrations, but cannot hear the sound pressure per se. Vibration and sound-pressure sensitivities were quantified by measuring brainstem evoked potentials in 11 royal pythons, Python regius. Vibrograms and audiograms showed greatest sensitivity at low frequencies of 80-160 Hz, with sensitivities of -54 dB re. 1 m s(-2) and 78 dB re. 20 μPa, respectively. To investigate whether pythons detect sound pressure or sound-induced head vibrations, we measured the sound-induced head vibrations in three dimensions when snakes were exposed to sound pressure at threshold levels. In general, head vibrations induced by threshold-level sound pressure were equal to or greater than those induced by threshold-level vibrations, and therefore sound-pressure sensitivity can be explained by sound-induced head vibration. From this we conclude that pythons, and possibly all snakes, lost effective pressure hearing with the complete reduction of a functional outer and middle ear, but have an acute vibration sensitivity that may be used for communication and detection of predators and prey.
Ultrasound visual feedback treatment and practice variability for residual speech sound errors
Preston, Jonathan L.; McCabe, Patricia; Rivera-Campos, Ahmed; Whittle, Jessica L.; Landry, Erik; Maas, Edwin
2014-01-01
Purpose The goals were to (1) test the efficacy of a motor-learning based treatment that includes ultrasound visual feedback for individuals with residual speech sound errors, and (2) explore whether the addition of prosodic cueing facilitates speech sound learning. Method A multiple baseline single subject design was used, replicated across 8 participants. For each participant, one sound context was treated with ultrasound plus prosodic cueing for 7 sessions, and another sound context was treated with ultrasound but without prosodic cueing for 7 sessions. Sessions included ultrasound visual feedback as well as non-ultrasound treatment. Word-level probes assessing untreated words were used to evaluate retention and generalization. Results For most participants, increases in accuracy of target sound contexts at the word level were observed with the treatment program regardless of whether prosodic cueing was included. Generalization between onset singletons and clusters was observed, as well as generalization to sentence-level accuracy. There was evidence of retention during post-treatment probes, including at a two-month follow-up. Conclusions A motor-based treatment program that includes ultrasound visual feedback can facilitate learning of speech sounds in individuals with residual speech sound errors. PMID:25087938
Opponent Coding of Sound Location (Azimuth) in Planum Temporale is Robust to Sound-Level Variations
Derey, Kiki; Valente, Giancarlo; de Gelder, Beatrice; Formisano, Elia
2016-01-01
Coding of sound location in auditory cortex (AC) is only partially understood. Recent electrophysiological research suggests that neurons in mammalian auditory cortex are characterized by broad spatial tuning and a preference for the contralateral hemifield, that is, a nonuniform sampling of sound azimuth. Additionally, spatial selectivity decreases with increasing sound intensity. To accommodate these findings, it has been proposed that sound location is encoded by the integrated activity of neuronal populations with opposite hemifield tuning (“opponent channel model”). In this study, we investigated the validity of such a model in human AC with functional magnetic resonance imaging (fMRI) and a phase-encoding paradigm employing binaural stimuli recorded individually for each participant. In all subjects, we observed preferential fMRI responses to contralateral azimuth positions. Additionally, in most AC locations, spatial tuning was broad and not level invariant. We derived an opponent channel model of the fMRI responses by subtracting the activity of contralaterally tuned regions in bilateral planum temporale. This resulted in accurate decoding of sound azimuth location, which was unaffected by changes in sound level. Our data thus support opponent channel coding as a neural mechanism for representing acoustic azimuth in human AC. PMID:26545618
Kim, Gibbeum; Han, Woojae
2018-05-01
The present study estimated the sound pressure levels of various music genres at the volume steps that contemporary smartphones deliver, because these levels put the listener at potential risk for hearing loss. Using six different smartphones (Galaxy S6, Galaxy Note 3, iPhone 5S, iPhone 6, LG G2, and LG G3), the sound pressure levels for three genres of K-pop music (dance-pop, hip-hop, and pop-ballad) and a Billboard pop chart of assorted genres were measured through an earbud for the first risk volume that was at the risk sign proposed by the smartphones, as well as consecutive higher volumes using a sound level meter and artificial mastoid. The first risk volume step of the Galaxy S6 and the LG G2, among the six smartphones, had the significantly lowest (84.1 dBA) and highest output levels (92.4 dBA), respectively. As the volume step increased, so did the sound pressure levels. The iPhone 6 was loudest (113.1 dBA) at the maximum volume step. Of the music genres, dance-pop showed the highest output level (91.1 dBA) for all smartphones. Within the frequency range of 20~ 20,000 Hz, the sound pressure level peaked at 2000 Hz for all the smartphones. The results showed that the sound pressure levels of either the first volume step or the maximum volume step were not the same for the different smartphone models and genres of music, which means that the risk volume sign and its output levels should be unified across the devices for their users. In addition, the risk volume steps proposed by the latest smartphone models are high enough to cause noise-induced hearing loss if their users habitually listen to music at those levels.
1987-09-01
stethoscope . Auscultation in respiratory medicine, however, has advanced slowly since Laennec established auscultation of lung sounds as a means of... stethoscope and the ear have limitations in their use as instruments for the evaluation of respiratory sounds. Respiratory sounds have a wide spectrum...Amplification, Rectification and Level-shft ing Stage ... 11 Respiratory Sound Circuitry ....... .................. ... 11 Sound Sensor
Sound recordings of road maintenance equipment on the Lincoln National Forest, New Mexico
D. K. Delaney; T. G. Grubb
2004-01-01
The purpose of this pilot study was to record, characterize, and quantify road maintenance activity in Mexican spotted owl (Strix occidentalis lucida) habitat to gauge potential sound level exposure for owls during road maintenance activities. We measured sound levels from three different types of road maintenance equipment (rock crusherlloader,...
49 CFR Appendix D to Part 227 - Audiometric Test Rooms
Code of Federal Regulations, 2011 CFR
2011-10-01
... sound pressure levels exceeding those in Table D-1 when measured by equipment conforming at least to the..._regulations/ibr_locations.html. Table D-1—Maximum Allowable Octave-Band Sound Pressure Levels for Audiometric Test Rooms Octave-band center frequency (Hz) 500 1000 2000 4000 8000 Sound pressure levels—supra-aural...
49 CFR Appendix D to Part 227 - Audiometric Test Rooms
Code of Federal Regulations, 2010 CFR
2010-10-01
... sound pressure levels exceeding those in Table D-1 when measured by equipment conforming at least to the..._regulations/ibr_locations.html. Table D-1—Maximum Allowable Octave-Band Sound Pressure Levels for Audiometric Test Rooms Octave-band center frequency (Hz) 500 1000 2000 4000 8000 Sound pressure levels—supra-aural...
Characterising the ambient sound environment for infants in intensive care wards.
Shoemark, Helen; Harcourt, Edward; Arnup, Sarah J; Hunt, Rod W
2016-04-01
The purpose of this study is to characterise ambient sound levels of paediatric and neonatal intensive care units in an old and new hospital according to current standards. The sound environment was surveyed for 24-h data collection periods (n = 80) in the Neonatal and Paediatric Intensive Care Units (NICUs and PICUs) and Special Care Nursery of the old and new Royal Children's Hospital Melbourne. The ambient sound environment was characterised as the proportion of time the ongoing ambient sound met standard benchmarks, the mean 5-s sound levels and the number and duration of noise events. In the old hospital, none of the data collection periods in the NICU and PICU met the standard benchmark for ongoing ambient sound, while only 5 of the 22 data collection periods in the new hospital met the recommended level. There was no change in proportion of time at recommended Leq between the old and the new Special Care Nursery. There was strong evidence for a difference in the mean number of events >65 dBA (Lmax ) in the old and new hospital (rate ratio = 0.82, 95% confidence interval: 0.73 to 0.92, P = 0.001). The NICU and PICU were above 50 dBA in 75% of all data collection periods, with ventilatory equipment associated with higher ongoing ambient sound levels. The ongoing ambient sound suggests that the background sound environment of the new hospital is not different to the old hospital. However, there may be a reduction in the number of noise events. © 2016 The Authors Journal of Paediatrics and Child Health © 2016 Paediatrics and Child Health Division (Royal Australasian College of Physicians).
Pedley, Adam J; Kitterick, Pádraig T
2017-09-01
Contra-lateral routing of signals (CROS) devices re-route sound between the deaf and hearing ears of unilaterally-deaf individuals. This rerouting would be expected to disrupt access to monaural level cues that can support monaural localisation in the horizontal plane. However, such a detrimental effect has not been confirmed by clinical studies of CROS use. The present study aimed to exercise strict experimental control over the availability of monaural cues to localisation in the horizontal plane and the fitting of the CROS device to assess whether signal routing can impair the ability to locate sources of sound and, if so, whether CROS selectively disrupts monaural level or spectral cues to horizontal location, or both. Unilateral deafness and CROS device use were simulated in twelve normal hearing participants. Monaural recordings of broadband white noise presented from three spatial locations (-60°, 0°, and +60°) were made in the ear canal of a model listener using a probe microphone with and without a CROS device. The recordings were presented to participants via an insert earphone placed in their right ear. The recordings were processed to disrupt either monaural level or spectral cues to horizontal sound location by roving presentation level or the energy across adjacent frequency bands, respectively. Localisation ability was assessed using a three-alternative forced-choice spatial discrimination task. Participants localised above chance levels in all conditions. Spatial discrimination accuracy was poorer when participants only had access to monaural spectral cues compared to when monaural level cues were available. CROS use impaired localisation significantly regardless of whether level or spectral cues were available. For both cues, signal re-routing had a detrimental effect on the ability to localise sounds originating from the side of the deaf ear (-60°). CROS use also impaired the ability to use level cues to localise sounds originating from straight ahead (0°). The re-routing of sounds can restrict access to the monaural cues that provide a basis for determining sound location in the horizontal plane. Perhaps encouragingly, the results suggest that both monaural level and spectral cues may not be disrupted entirely by signal re-routing and that it may still be possible to reliably identify sounds originating on the hearing side. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Knobel, Keila Alessandra Baraldi; Lima, Maria Cecília Marconi Pinheiro
2014-01-01
Exposure to loud sound during leisure activities for long periods of time is an important area to implement preventive health education, especially among young people. The aim was to identify the relations among awareness about the damaging effects of loud levels of sounds, previous exposures do loud sounds, preferences-related to sound levels and knowledge about hearing protection with age, gender, and their parent's educational level among children. Prospective cross-sectional. Seven hundred and forty students (5-16 years old) and 610 parents participated in the study. Chi-square test, Fisher exact test and linear regression. About 86.5% of the children consider that loud sounds damage the ears and 53.7% dislike noisy places. Children were previously exposed to parties and concerts with loud music, Mardi Gras, firecrackers and loud music at home or in the car and loud music with earphones. About 18.4% of the younger children could select the volume of the music, versus 65.3% of the older ones. Children have poor information about hearing protection and do not have hearing protection device. Knowledge about the risks related to exposures to loud sounds and about strategies to protect their hearing increases with age, but preference for loud sounds and exposures to it increases too. Gender and parents' instructional level have little influence on the studied variables. Many of the children's recreational activities are noisy. It is possible that the tendency of increasing preference for loud sounds with age might be a result of a learned behavior.
Sanchez, Tanit Ganz; Moraes, Fernanda; Casseb, Juliana; Cota, Jaci; Freire, Katya; Roberts, Larry E.
2016-01-01
Recent neuroscience research suggests that tinnitus may reflect synaptic loss in the cochlea that does not express in the audiogram but leads to neural changes in auditory pathways that reduce sound level tolerance (SLT). Adolescents (N = 170) completed a questionnaire addressing their prior experience with tinnitus, potentially risky listening habits, and sensitivity to ordinary sounds, followed by psychoacoustic measurements in a sound booth. Among all adolescents 54.7% reported by questionnaire that they had previously experienced tinnitus, while 28.8% heard tinnitus in the booth. Psychoacoustic properties of tinnitus measured in the sound booth corresponded with those of chronic adult tinnitus sufferers. Neither hearing thresholds (≤15 dB HL to 16 kHz) nor otoacoustic emissions discriminated between adolescents reporting or not reporting tinnitus in the sound booth, but loudness discomfort levels (a psychoacoustic measure of SLT) did so, averaging 11.3 dB lower in adolescents experiencing tinnitus in the acoustic chamber. Although risky listening habits were near universal, the teenagers experiencing tinnitus and reduced SLT tended to be more protective of their hearing. Tinnitus and reduced SLT could be early indications of a vulnerability to hidden synaptic injury that is prevalent among adolescents and expressed following exposure to high level environmental sounds. PMID:27265722
Measor, Kevin R; Leavell, Brian C; Brewton, Dustin H; Rumschlag, Jeffrey; Barber, Jesse R; Razak, Khaleel A
2017-01-01
In active sensing, animals make motor adjustments to match sensory inputs to specialized neural circuitry. Here, we describe an active sensing system for sound level processing. The pallid bat uses downward frequency-modulated (FM) sweeps as echolocation calls for general orientation and obstacle avoidance. The bat's auditory cortex contains a region selective for these FM sweeps (FM sweep-selective region, FMSR). We show that the vast majority of FMSR neurons are sensitive and strongly selective for relatively low levels (30-60 dB SPL). Behavioral testing shows that when a flying bat approaches a target, it reduces output call levels to keep echo levels between ∼30 and 55 dB SPL. Thus, the pallid bat behaviorally matches echo levels to an optimized neural representation of sound levels. FMSR neurons are more selective for sound levels of FM sweeps than tones, suggesting that across-frequency integration enhances level tuning. Level-dependent timing of high-frequency sideband inhibition in the receptive field shapes increased level selectivity for FM sweeps. Together with previous studies, these data indicate that the same receptive field properties shape multiple filters (sweep direction, rate, and level) for FM sweeps, a sound common in multiple vocalizations, including human speech. The matched behavioral and neural adaptations for low-intensity echolocation in the pallid bat will facilitate foraging with reduced probability of acoustic detection by prey.
Measor, Kevin R.; Leavell, Brian C.; Brewton, Dustin H.; Rumschlag, Jeffrey; Barber, Jesse R.
2017-01-01
Abstract In active sensing, animals make motor adjustments to match sensory inputs to specialized neural circuitry. Here, we describe an active sensing system for sound level processing. The pallid bat uses downward frequency-modulated (FM) sweeps as echolocation calls for general orientation and obstacle avoidance. The bat’s auditory cortex contains a region selective for these FM sweeps (FM sweep-selective region, FMSR). We show that the vast majority of FMSR neurons are sensitive and strongly selective for relatively low levels (30-60 dB SPL). Behavioral testing shows that when a flying bat approaches a target, it reduces output call levels to keep echo levels between ∼30 and 55 dB SPL. Thus, the pallid bat behaviorally matches echo levels to an optimized neural representation of sound levels. FMSR neurons are more selective for sound levels of FM sweeps than tones, suggesting that across-frequency integration enhances level tuning. Level-dependent timing of high-frequency sideband inhibition in the receptive field shapes increased level selectivity for FM sweeps. Together with previous studies, these data indicate that the same receptive field properties shape multiple filters (sweep direction, rate, and level) for FM sweeps, a sound common in multiple vocalizations, including human speech. The matched behavioral and neural adaptations for low-intensity echolocation in the pallid bat will facilitate foraging with reduced probability of acoustic detection by prey. PMID:28275715
Sound Levels in East Texas Schools.
ERIC Educational Resources Information Center
Turner, Aaron Lynn
A survey of sound levels was taken in several Texas schools to determine the amount of noise and sound present by size of class, type of activity, location of building, and the presence of air conditioning and large amounts of glass. The data indicate that class size and relative amounts of glass have no significant bearing on the production of…
The influence of the level formants on the perception of synthetic vowel sounds
NASA Astrophysics Data System (ADS)
Kubzdela, Henryk; Owsianny, Mariuz
A computer model of a generator of periodic complex sounds simulating consonants was developed. The system makes possible independent regulation of the level of each of the formants and instant generation of the sound. A trapezoid approximates the curve of the spectrum within the range of the formant. In using this model, each person in a group of six listeners experimentally selected synthesis parameters for six sounds that to him seemed optimal approximations of Polish consonants. From these, another six sounds were selected that were identified by a majority of the six persons and several additional listeners as being best qualified to serve as prototypes of Polish consonants. These prototypes were then used to randomly create sounds with various combinations at the level of the second and third formant and these were presented to seven listeners for identification. The results of the identifications are presented in table form in three variants and are described from the point of view of the requirements of automatic recognition of consonants in continuous speech.
Mitigation of Sri Lanka Island Effects in Colombo Sounding Data during DYNAMO
NASA Astrophysics Data System (ADS)
Ciesielski, P. E.; Johnson, R. H.; Yoneyama, K.
2013-12-01
During the Dynamics of the MJO (DYNAMO) field campaign, upper-air soundings were launched at Colombo, Sri Lanka as part of the enhanced northern sounding array (NSA) of the experiment. The Colombo soundings were affected at low-levels by diurnal heating of this large island and by flow blocking due to elevated terrain to the east of the Colombo site. Because of the large spacing between sounding sites, these small-scale effects are aliased onto the larger scale impacting analyses and atmospheric budgets over the DYNAMO NSA. To mitigate these local island effects on the large-scale budgets, a procedure was designed which uses ECMWF-analyzed fields in the vicinity of Sri Lanka to estimate open-ocean conditions (i.e, as if this island were not present). These 'unperturbed' ECMWF fields at low-levels are then merged with observed Colombo soundings. This procedure effectively mutes the blocking effects and large diurnal cycle observed in the low-level Colombo fields. In westerly flow regimes, adjusted Colombo winds increase the low-level westerlies by 2-3 m/s with a similar increase of the low-level easterlies in easterly flow regimes. In general, over the NSA the impact of the adjusted Colombo winds results in more low-level divergence (convergence), more mid-level subsidence (rising motion) and reduced (increased) rainfall during the westerly (easterly) wind regimes. In comparison to independent TRMM rainfall estimates, both the mean budget-derived rainfall and its temporal correlation are improved by using the adjusted Colombo soundings. In addition, use of the 'unperturbed' fields result in a more realistic moisture budget analyses, both in its diurnal cycle and during the build-up phase of the November MJO when a gradual deepening of apparent drying was observed. Overall, use of the adjusted Colombo soundings appears to have a beneficial impact on the NSA analyses and budgets.
Why Do People Like Loud Sound? A Qualitative Study
Welch, David; Fremaux, Guy
2017-01-01
Many people choose to expose themselves to potentially dangerous sounds such as loud music, either via speakers, personal audio systems, or at clubs. The Conditioning, Adaptation and Acculturation to Loud Music (CAALM) Model has proposed a theoretical basis for this behaviour. To compare the model to data, we interviewed a group of people who were either regular nightclub-goers or who controlled the sound levels in nightclubs (bar managers, musicians, DJs, and sound engineers) about loud sound. Results showed four main themes relating to the enjoyment of loud sound: arousal/excitement, facilitation of socialisation, masking of both external sound and unwanted thoughts, and an emphasis and enhancement of personal identity. Furthermore, an interesting incidental finding was that sound levels appeared to increase gradually over the course of the evening until they plateaued at approximately 97 dBA Leq around midnight. Consideration of the data generated by the analysis revealed a complex of influential factors that support people in wanting exposure to loud sound. Findings were considered in terms of the CAALM Model and could be explained in terms of its principles. From a health promotion perspective, the Social Ecological Model was applied to consider how the themes identified might influence behaviour. They were shown to influence people on multiple levels, providing a powerful system which health promotion approaches struggle to address. PMID:28800097
Liu, Juan; Ando, Hiroshi
2016-01-01
Most real-world events stimulate multiple sensory modalities simultaneously. Usually, the stiffness of an object is perceived haptically. However, auditory signals also contain stiffness-related information, and people can form impressions of stiffness from the different impact sounds of metal, wood, or glass. To understand whether there is any interaction between auditory and haptic stiffness perception, and if so, whether the inferred material category is the most relevant auditory information, we conducted experiments using a force-feedback device and the modal synthesis method to present haptic stimuli and impact sound in accordance with participants’ actions, and to modulate low-level acoustic parameters, i.e., frequency and damping, without changing the inferred material categories of sound sources. We found that metal sounds consistently induced an impression of stiffer surfaces than did drum sounds in the audio-only condition, but participants haptically perceived surfaces with modulated metal sounds as significantly softer than the same surfaces with modulated drum sounds, which directly opposes the impression induced by these sounds alone. This result indicates that, although the inferred material category is strongly associated with audio-only stiffness perception, low-level acoustic parameters, especially damping, are more tightly integrated with haptic signals than the material category is. Frequency played an important role in both audio-only and audio-haptic conditions. Our study provides evidence that auditory information influences stiffness perception differently in unisensory and multisensory tasks. Furthermore, the data demonstrated that sounds with higher frequency and/or shorter decay time tended to be judged as stiffer, and contact sounds of stiff objects had no effect on the haptic perception of soft surfaces. We argue that the intrinsic physical relationship between object stiffness and acoustic parameters may be applied as prior knowledge to achieve robust estimation of stiffness in multisensory perception. PMID:27902718
Noise in contemporary neonatal intensive care.
Williams, Amber L; van Drongelen, Wim; Lasky, Robert E
2007-05-01
Weekly sound surveys (n = 63) were collected, using 5 s sampling intervals, for two modern neonatal intensive care units (NICUs). Median weekly equivalent sound pressure levels (LEQ) for NICU A ranged from 61 to 63 dB (A weighted), depending on the level of care. NICU B L(EQ) measurements ranged from 55 to 60 dB (A weighted). NICU B was recently built with a focus on sound abatement, explaining much of the difference between the two NICUs. Sound levels exceeded 45 dB (A weighted), recommended by the American Academy of Pediatrics, more than 70% of the time for all levels of care. Hourly L(EQ)s below 50 dB (A weighted) and hourly L10s below 55 dB (A weighted), recommended by the Sound Study Group (SSG) of the National Resource Center, were also exceeded in more than 70% of recorded samples. A third SSG recommendation, that the 1 s L(MAX), should not exceed 70 dB (A weighted), was exceeded relatively infrequently (< 11% of the time). Peak impulse measurements exceeded 90 dB for 6.3% of 5 s samples recorded from NICU A and 2.8% of NICU B samples. Twenty-four h periodicities in sound levels as a function of regular staff activities were apparent, but short-term variability was considerable.
Opponent Coding of Sound Location (Azimuth) in Planum Temporale is Robust to Sound-Level Variations.
Derey, Kiki; Valente, Giancarlo; de Gelder, Beatrice; Formisano, Elia
2016-01-01
Coding of sound location in auditory cortex (AC) is only partially understood. Recent electrophysiological research suggests that neurons in mammalian auditory cortex are characterized by broad spatial tuning and a preference for the contralateral hemifield, that is, a nonuniform sampling of sound azimuth. Additionally, spatial selectivity decreases with increasing sound intensity. To accommodate these findings, it has been proposed that sound location is encoded by the integrated activity of neuronal populations with opposite hemifield tuning ("opponent channel model"). In this study, we investigated the validity of such a model in human AC with functional magnetic resonance imaging (fMRI) and a phase-encoding paradigm employing binaural stimuli recorded individually for each participant. In all subjects, we observed preferential fMRI responses to contralateral azimuth positions. Additionally, in most AC locations, spatial tuning was broad and not level invariant. We derived an opponent channel model of the fMRI responses by subtracting the activity of contralaterally tuned regions in bilateral planum temporale. This resulted in accurate decoding of sound azimuth location, which was unaffected by changes in sound level. Our data thus support opponent channel coding as a neural mechanism for representing acoustic azimuth in human AC. © The Author 2015. Published by Oxford University Press.
Detection System of Sound Noise Level (SNL) Based on Condenser Microphone Sensor
NASA Astrophysics Data System (ADS)
Rajagukguk, Juniastel; Eka Sari, Nurdieni
2018-03-01
The research aims to know the noise level by using the Arduino Uno as data processing input from sensors and called as Sound Noise Level (SNL). The working principle of the instrument is as noise detector with the show notifications the noise level on the LCD indicator and in the audiovisual form. Noise detection using the sensor is a condenser microphone and LM 567 as IC op-amps, which are assembled so that it can detect the noise, which sounds are captured by the sensor will turn the tide of sinusoida voice became sine wave energy electricity (altering sinusoida electric current) that is able to responded to complaints by the Arduino Uno. The tool is equipped with a detector consists of a set indicator LED and sound well as the notification from the text on LCD 16*2. Work setting indicators on the condition that, if the measured noise > 75 dB then sound will beep, the red LED will light up indicating the status of the danger. If the measured value on the LCD is higher than 56 dB, sound indicator will be beep and yellow LED will be on indicating noisy. If the noise measured value <55 dB, sound indicator will be quiet indicating peaceful from noisy. From the result of the research can be explained that the SNL is capable to detecting and displaying noise level with a measuring range 50-100 dB and capable to delivering the notification noise in audiovisual.
Drilling and operational sounds from an oil production island in the ice-covered Beaufort sea.
Blackwell, Susanna B; Greene, Charles R; Richardson, W John
2004-11-01
Recordings of sounds underwater and in air, and of iceborne vibrations, were obtained at Northstar Island, an artificial gravel island in the Beaufort Sea near Prudhoe Bay (Alaska). The aim was to document the levels, characteristics, and range dependence of sounds and vibrations produced by drilling and oil production during the winter, when the island was surrounded by shore-fast ice. Drilling produced the highest underwater broadband (10-10,000 Hz) levels (maximum= 124 dB re: 1 microPa at 1 km), and mainly affected 700-1400 Hz frequencies. In contrast, drilling did not increase broadband levels in air or ice relative to levels during other island activities. Production did not increase broadband levels for any of the sensors. In all media, broadband levels decreased by approximately 20 dB/tenfold change in distance. Background levels underwater were reached by 9.4 km during drilling and 3-4 km without. In the air and ice, background levels were reached 5-10 km and 2-10 km from Northstar, respectively, depending on the wind but irrespective of drilling. A comparison of the recorded sounds with harbor and ringed seal audiograms showed that Northstar sounds were probably audible to seals, at least intermittently, out to approximately 1.5 km in water and approximately 5 km in air.
AVE/VAS 4: 25-mb sounding data
NASA Technical Reports Server (NTRS)
Sienkiewicz, M. E.
1983-01-01
The rawinsonde sounding program is described and tabulated data at 25 mb intervals for the 24 stations and 14 special stations participating in the experiment is presented. Sounding were taken at 3 hr intervals. An additional sounding was taken at the normal synoptic observation time. Some soundings were computed from raw ordinate data, while others were interpolated from significant level data.
Interpolated Sounding and Gridded Sounding Value-Added Products
DOE Office of Scientific and Technical Information (OSTI.GOV)
Toto, T.; Jensen, M.
Standard Atmospheric Radiation Measurement (ARM) Climate Research Facility sounding files provide atmospheric state data in one dimension of increasing time and height per sonde launch. Many applications require a quick estimate of the atmospheric state at higher time resolution. The INTERPOLATEDSONDE (i.e., Interpolated Sounding) Value-Added Product (VAP) transforms sounding data into continuous daily files on a fixed time-height grid, at 1-minute time resolution, on 332 levels, from the surface up to a limit of approximately 40 km. The grid extends that high so the full height of soundings can be captured; however, most soundings terminate at an altitude between 25more » and 30 km, above which no data is provided. Between soundings, the VAP linearly interpolates atmospheric state variables in time for each height level. In addition, INTERPOLATEDSONDE provides relative humidity scaled to microwave radiometer (MWR) observations.The INTERPOLATEDSONDE VAP, a continuous time-height grid of relative humidity-corrected sounding data, is intended to provide input to higher-order products, such as the Merged Soundings (MERGESONDE; Troyan 2012) VAP, which extends INTERPOLATEDSONDE by incorporating model data. The INTERPOLATEDSONDE VAP also is used to correct gaseous attenuation of radar reflectivity in products such as the KAZRCOR VAP.« less
Claes, Raf; Muyshondt, Pieter G G; Dirckx, Joris J J; Aerts, Peter
2018-02-01
High sound pressure levels (>120dB) cause damage or death of the hair cells of the inner ear, hence causing hearing loss. Vocalization differences are present between hens and roosters. Crowing in roosters is reported to produce sound pressure levels of 100dB measured at a distance of 1m. In this study we measured the sound pressure levels that exist at the entrance of the outer ear canal. We hypothesize that roosters may benefit from a passive protective mechanism while hens do not require such a mechanism. Audio recordings at the level of the entrance of the outer ear canal of crowing roosters, made in this study, indeed show that a protective mechanism is needed as sound pressure levels can reach amplitudes of 142.3dB. Audio recordings made at varying distances from the crowing rooster show that at a distance of 0.5m sound pressure levels already drop to 102dB. Micro-CT scans of a rooster and chicken head show that in roosters the auditory canal closes when the beak is opened. In hens the diameter of the auditory canal only narrows but does not close completely. A morphological difference between the sexes in shape of a bursa-like slit which occurs in the outer ear canal causes the outer ear canal to close in roosters but not in hens. Copyright © 2017 Elsevier GmbH. All rights reserved.
49 CFR 227.103 - Noise monitoring program.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., significant variations in sound level, or a significant component of impulse noise make area monitoring... results. (c) Noise measurements. (1) All continuous, intermittent, and impulse sound levels from 80...
49 CFR 227.103 - Noise monitoring program.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., significant variations in sound level, or a significant component of impulse noise make area monitoring... results. (c) Noise measurements. (1) All continuous, intermittent, and impulse sound levels from 80...
49 CFR 227.103 - Noise monitoring program.
Code of Federal Regulations, 2013 CFR
2013-10-01
..., significant variations in sound level, or a significant component of impulse noise make area monitoring... results. (c) Noise measurements. (1) All continuous, intermittent, and impulse sound levels from 80...
Stanley, Jenni A; Van Parijs, Sofie M; Hatch, Leila T
2017-11-07
Stellwagen Bank National Marine Sanctuary is located in Massachusetts Bay off the densely populated northeast coast of the United States; subsequently, the marine inhabitants of the area are exposed to elevated levels of anthropogenic underwater sound, particularly due to commercial shipping. The current study investigated the alteration of estimated effective communication spaces at three spawning locations for populations of the commercially and ecologically important fishes, Atlantic cod (Gadus morhua) and haddock (Melanogrammus aeglefinus). Both the ambient sound pressure levels and the estimated effective vocalization radii, estimated through spherical spreading models, fluctuated dramatically during the three-month recording periods. Increases in sound pressure level appeared to be largely driven by large vessel activity, and accordingly exhibited a significant positive correlation with the number of Automatic Identification System tracked vessels at the two of the three sites. The near constant high levels of low frequency sound and consequential reduction in the communication space observed at these recording sites during times of high vocalization activity raises significant concerns that communication between conspecifics may be compromised during critical biological periods. This study takes the first steps in evaluating these animals' communication spaces and alteration of these spaces due to anthropogenic underwater sound.
Cell type-specific suppression of mechanosensitive genes by audible sound stimulation.
Kumeta, Masahiro; Takahashi, Daiji; Takeyasu, Kunio; Yoshimura, Shige H
2018-01-01
Audible sound is a ubiquitous environmental factor in nature that transmits oscillatory compressional pressure through the substances. To investigate the property of the sound as a mechanical stimulus for cells, an experimental system was set up using 94.0 dB sound which transmits approximately 10 mPa pressure to the cultured cells. Based on research on mechanotransduction and ultrasound effects on cells, gene responses to the audible sound stimulation were analyzed by varying several sound parameters: frequency, wave form, composition, and exposure time. Real-time quantitative PCR analyses revealed a distinct suppressive effect for several mechanosensitive and ultrasound-sensitive genes that were triggered by sounds. The effect was clearly observed in a wave form- and pressure level-specific manner, rather than the frequency, and persisted for several hours. At least two mechanisms are likely to be involved in this sound response: transcriptional control and RNA degradation. ST2 stromal cells and C2C12 myoblasts exhibited a robust response, whereas NIH3T3 cells were partially and NB2a neuroblastoma cells were completely insensitive, suggesting a cell type-specific response to sound. These findings reveal a cell-level systematic response to audible sound and uncover novel relationships between life and sound.
Cell type-specific suppression of mechanosensitive genes by audible sound stimulation
Takahashi, Daiji; Takeyasu, Kunio; Yoshimura, Shige H.
2018-01-01
Audible sound is a ubiquitous environmental factor in nature that transmits oscillatory compressional pressure through the substances. To investigate the property of the sound as a mechanical stimulus for cells, an experimental system was set up using 94.0 dB sound which transmits approximately 10 mPa pressure to the cultured cells. Based on research on mechanotransduction and ultrasound effects on cells, gene responses to the audible sound stimulation were analyzed by varying several sound parameters: frequency, wave form, composition, and exposure time. Real-time quantitative PCR analyses revealed a distinct suppressive effect for several mechanosensitive and ultrasound-sensitive genes that were triggered by sounds. The effect was clearly observed in a wave form- and pressure level-specific manner, rather than the frequency, and persisted for several hours. At least two mechanisms are likely to be involved in this sound response: transcriptional control and RNA degradation. ST2 stromal cells and C2C12 myoblasts exhibited a robust response, whereas NIH3T3 cells were partially and NB2a neuroblastoma cells were completely insensitive, suggesting a cell type-specific response to sound. These findings reveal a cell-level systematic response to audible sound and uncover novel relationships between life and sound. PMID:29385174
Meteorological effects on long-range outdoor sound propagation
NASA Technical Reports Server (NTRS)
Klug, Helmut
1990-01-01
Measurements of sound propagation over distances up to 1000 m were carried out with an impulse sound source offering reproducible, short time signals. Temperature and wind speed at several heights were monitored simultaneously; the meteorological data are used to determine the sound speed gradients according to the Monin-Obukhov similarity theory. The sound speed profile is compared to a corresponding prediction, gained through the measured travel time difference between direct and ground reflected pulse (which depends on the sound speed gradient). Positive sound speed gradients cause bending of the sound rays towards the ground yielding enhanced sound pressure levels. The measured meteorological effects on sound propagation are discussed and illustrated by ray tracing methods.
Sound Wave Energy Resulting from the Impact of Water Drops on the Soil Surface
Ryżak, Magdalena; Bieganowski, Andrzej; Korbiel, Tomasz
2016-01-01
The splashing of water drops on a soil surface is the first step of water erosion. There have been many investigations into splashing–most are based on recording and analysing images taken with high-speed cameras, or measuring the mass of the soil moved by splashing. Here, we present a new aspect of the splash phenomenon’s characterization the measurement of the sound pressure level and the sound energy of the wave that propagates in the air. The measurements were carried out for 10 consecutive water drop impacts on the soil surface. Three soils were tested (Endogleyic Umbrisol, Fluvic Endogleyic Cambisol and Haplic Chernozem) with four initial moisture levels (pressure heads: 0.1 kPa, 1 kPa, 3.16 kPa and 16 kPa). We found that the values of the sound pressure and sound wave energy were dependent on the particle size distribution of the soil, less dependent on the initial pressure head, and practically the same for subsequent water drops (from the first to the tenth drop). The highest sound pressure level (and the greatest variability) was for Endogleyic Umbrisol, which had the highest sand fraction content. The sound pressure for this soil increased from 29 dB to 42 dB with the next incidence of drops falling on the sample The smallest (and the lowest variability) was for Fluvic Endogleyic Cambisol which had the highest clay fraction. For all experiments the sound pressure level ranged from ~27 to ~42 dB and the energy emitted in the form of sound waves was within the range of 0.14 μJ to 5.26 μJ. This was from 0.03 to 1.07% of the energy of the incident drops. PMID:27388276
Sound Wave Energy Resulting from the Impact of Water Drops on the Soil Surface.
Ryżak, Magdalena; Bieganowski, Andrzej; Korbiel, Tomasz
2016-01-01
The splashing of water drops on a soil surface is the first step of water erosion. There have been many investigations into splashing-most are based on recording and analysing images taken with high-speed cameras, or measuring the mass of the soil moved by splashing. Here, we present a new aspect of the splash phenomenon's characterization the measurement of the sound pressure level and the sound energy of the wave that propagates in the air. The measurements were carried out for 10 consecutive water drop impacts on the soil surface. Three soils were tested (Endogleyic Umbrisol, Fluvic Endogleyic Cambisol and Haplic Chernozem) with four initial moisture levels (pressure heads: 0.1 kPa, 1 kPa, 3.16 kPa and 16 kPa). We found that the values of the sound pressure and sound wave energy were dependent on the particle size distribution of the soil, less dependent on the initial pressure head, and practically the same for subsequent water drops (from the first to the tenth drop). The highest sound pressure level (and the greatest variability) was for Endogleyic Umbrisol, which had the highest sand fraction content. The sound pressure for this soil increased from 29 dB to 42 dB with the next incidence of drops falling on the sample The smallest (and the lowest variability) was for Fluvic Endogleyic Cambisol which had the highest clay fraction. For all experiments the sound pressure level ranged from ~27 to ~42 dB and the energy emitted in the form of sound waves was within the range of 0.14 μJ to 5.26 μJ. This was from 0.03 to 1.07% of the energy of the incident drops.
The isolation of low frequency impact sounds in hotel construction
NASA Astrophysics Data System (ADS)
LoVerde, John J.; Dong, David W.
2002-11-01
One of the design challenges in the acoustical design of hotels is reducing low frequency sounds from footfalls occurring on both carpeted and hard-surfaced floors. Research on low frequency impact noise [W. Blazier and R. DuPree, J. Acoust. Soc. Am. 96, 1521-1532 (1994)] resulted in a conclusion that in wood construction low frequency impact sounds were clearly audible and that feasible control methods were not available. The results of numerous FIIC (Field Impact Insulation Class) measurements performed in accordance with ASTM E1007 indicate the lack of correlation between FIIC ratings and the reaction of occupants in the room below. The measurements presented include FIIC ratings and sound pressure level measurements below the ASTM E1007 low frequency limit of 100 Hertz, and reveal that excessive sound levels in the frequency range of 63 to 100 Hertz correlate with occupant complaints. Based upon this history, a tentative criterion for maximum impact sound level in the low frequency range is presented. The results presented of modifying existing constructions to reduce the transmission of impact sounds at low frequencies indicate that there may be practical solutions to this longstanding problem.
[Expression of NR2A in rat auditory cortex after sound insulation and auditory plasticity].
Xia, Yin; Long, Haishan; Han, Demin; Gong, Shusheng; Lei, Li; Shi, Jinfeng; Fan, Erzhong; Li, Ying; Zhao, Qing
2009-06-01
To study the changes of N-methyl-D-aspartate (NMDA) receptor subunit 2A (NR2A) expression at local synapses in auditory cortices after early postnatal sound insulation and tone exposure. We prepared highly purified synaptosomes from primary auditory cortex by Optiprep flotation gradient centrifugations, and compared the differences of NR2A expression in sound insulation PND14, PND28, PND42 and Tone exposure after sound insulation for 7 days by Western blotting. The results showed that the NR2A protein expression of PND14 and PND28 decreased significantly (P<0.05). Tone exposure after sound insulation for 7 days, mSIe NR2A protein level increased significantly (P<0.05). It showed bidirectional regulation of NR2A protein. No significant effects of sound insulation and lone exposure were found on the relative expression level of NR2A of PND42 (P>0.05). The results indicate that sound insulation and experience can modify the protein expression level of NR2A during the critical period of rat postnatal development. These findings provide important data for the study on the mechanisms of the developmental plasticity of sensory functions.
Measurement and characterisation of radiated underwater sound from a 3.6 MW monopile wind turbine.
Pangerc, Tanja; Theobald, Peter D; Wang, Lian S; Robinson, Stephen P; Lepper, Paul A
2016-10-01
This paper describes underwater sound pressure measurements obtained in close proximity (∼50 m) to two individual wind turbines, over a 21-day period, capturing the full range of turbine operating conditions. The sound radiated into the water was characterised by a number of tonal components, which are thought to primarily originate from the gearbox for the bandwidth measured. The main signal associated with the turbine operation had a mean-square sound pressure spectral density level which peaked at 126 dB re 1 μPa 2 Hz -1 at 162 Hz. Other tonal components were also present, notably at frequencies between about 20 and 330 Hz, albeit at lower amplitudes. The measured sound characteristics, both in terms of frequency and amplitude, were shown to vary with wind speed. The sound pressure level increased with wind speed up to an average value of 128 dB re 1 μPa at a wind speed of about 10 ms -1 , and then showed a general decrease. Overall, differences in the mean-square sound pressure spectral density level of over 20 dB were observed across the operational envelope of the turbine.
Designing sound and visual components for enhancement of urban soundscapes.
Hong, Joo Young; Jeon, Jin Yong
2013-09-01
The aim of this study is to investigate the effect of audio-visual components on environmental quality to improve soundscape. Natural sounds with road traffic noise and visual components in urban streets were evaluated through laboratory experiments. Waterfall and stream water sounds, as well as bird sounds, were selected to enhance the soundscape. Sixteen photomontages of a streetscape were constructed in combination with two types of water features and three types of vegetation which were chosen as positive visual components. The experiments consisted of audio-only, visual-only, and audio-visual conditions. The preferences and environmental qualities of the stimuli were evaluated by a numerical scale and 12 pairs of adjectives, respectively. The results showed that bird sounds were the most preferred among the natural sounds, while the sound of falling water was found to degrade the soundscape quality when the road traffic noise level was high. The visual effects of vegetation on aesthetic preference were significant, but those of water features relatively small. It was revealed that the perceptual dimensions of the environment were different from the noise levels. Particularly, the acoustic comfort factor related to soundscape quality considerably influenced preference for the overall environment at a higher level of road traffic noise.
Lenzuni, Paolo
2015-07-01
The purpose of this article is to develop a method for the statistical inference of the maximum peak sound pressure level and of the associated uncertainty. Both quantities are requested by the EU directive 2003/10/EC for a complete and solid assessment of the noise exposure at the workplace. Based on the characteristics of the sound pressure waveform, it is hypothesized that the distribution of the measured peak sound pressure levels follows the extreme value distribution. The maximum peak level is estimated as the largest member of a finite population following this probability distribution. The associated uncertainty is also discussed, taking into account not only the contribution due to the incomplete sampling but also the contribution due to the finite precision of the instrumentation. The largest of the set of measured peak levels underestimates the maximum peak sound pressure level. The underestimate can be as large as 4 dB if the number of measurements is limited to 3-4, which is common practice in occupational noise assessment. The extended uncertainty is also quite large (~2.5 dB), with a weak dependence on the sampling details. Following the procedure outlined in this article, a reliable comparison between the peak sound pressure levels measured in a workplace and the EU directive action limits is possible. Non-compliance can occur even when the largest of the set of measured peak levels is several dB below such limits. © The Author 2015. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
Noise in the operating rooms of Greek hospitals.
Tsiou, Chrisoula; Efthymiatos, Gerasimos; Katostaras, Theophanis
2008-02-01
This study is an evaluation of the problem of noise pollution in operating rooms. The high sound pressure level of noise in the operating theatre has a negative impact on communication between operating room personnel. The research took place at nine Greek public hospitals with more than 400 beds. The objective evaluation consisted of sound pressure level measurements in terms of L(eq), as well as peak sound pressure levels in recordings during 43 surgeries in order to identify sources of noise. The subjective evaluation consisted of a questionnaire answered by 684 operating room personnel. The views of operating room personnel were studied using Pearson's X(2) Test and Fisher's Exact Test (SPSS Version 10.00), a t-test comparison was made of mean sound pressure levels, and the relationship of measurement duration and sound pressure level was examined using linear regression analysis (SPSS Version 13.00). The sound pressure levels of noise per operation and the sources of noise varied. The maximum measured level of noise during the main procedure of an operation was measured at L(eq)=71.9 dB(A), L(1)=84.7 dB(A), L(10)=76.2 dB(A), and L(99)=56.7 dB(A). The hospital building, machinery, tools, and people in the operating room were the main noise factors. In order to eliminate excess noise in the operating room it may be necessary to adopt a multidisciplinary approach. An improvement in environment (background noise levels), the implementation of effective standards, and the focusing of the surgical team on noise matters are considered necessary changes.
Mapping the sound field of an erupting submarine volcano using an acoustic glider.
Matsumoto, Haru; Haxel, Joseph H; Dziak, Robert P; Bohnenstiehl, Delwayne R; Embley, Robert W
2011-03-01
An underwater glider with an acoustic data logger flew toward a recently discovered erupting submarine volcano in the northern Lau basin. With the volcano providing a wide-band sound source, recordings from the two-day survey produced a two-dimensional sound level map spanning 1 km (depth) × 40 km(distance). The observed sound field shows depth- and range-dependence, with the first-order spatial pattern being consistent with the predictions of a range-dependent propagation model. The results allow constraining the acoustic source level of the volcanic activity and suggest that the glider provides an effective platform for monitoring natural and anthropogenic ocean sounds. © 2011 Acoustical Society of America
Designing Trend-Monitoring Sounds for Helicopters: Methodological Issues and an Application
ERIC Educational Resources Information Center
Edworthy, Judy; Hellier, Elizabeth; Aldrich, Kirsteen; Loxley, Sarah
2004-01-01
This article explores methodological issues in sonification and sound design arising from the design of helicopter monitoring sounds. Six monitoring sounds (each with 5 levels) were tested for similarity and meaning with 3 different techniques: hierarchical cluster analysis, linkage analysis, and multidimensional scaling. In Experiment 1,…
Kastelein, Ronald A; Wensveen, Paul J; Terhune, John M; de Jong, Christ A F
2011-01-01
Equal-loudness functions describe relationships between the frequencies of sounds and their perceived loudness. This pilot study investigated the possibility of deriving equal-loudness contours based on the assumption that sounds of equal perceived loudness elicit equal reaction times (RTs). During a psychoacoustic underwater hearing study, the responses of two young female harbor seals to tonal signals between 0.125 and 100 kHz were filmed. Frame-by-frame analysis was used to quantify RT (the time between the onset of the sound stimulus and the onset of movement of the seal away from the listening station). Near-threshold equal-latency contours, as surrogates for equal-loudness contours, were estimated from RT-level functions fitted to mean RT data. The closer the received sound pressure level was to the 50% detection hearing threshold, the more slowly the animals reacted to the signal (RT range: 188-982 ms). Equal-latency contours were calculated relative to the RTs shown by each seal at sound levels of 0, 10, and 20 dB above the detection threshold at 1 kHz. Fifty percent detection thresholds are obtained with well-trained subjects actively listening for faint familiar sounds. When calculating audibility ranges of sounds for harbor seals in nature, it may be appropriate to consider levels 20 dB above this threshold.
Kok, Annebelle C M; Engelberts, J Pamela; Kastelein, Ronald A; Helder-Hoek, Lean; Van de Voorde, Shirley; Visser, Fleur; Slabbekoorn, Hans
2018-02-01
The continuing rise in underwater sound levels in the oceans leads to disturbance of marine life. It is thought that one of the main impacts of sound exposure is the alteration of foraging behaviour of marine species, for example by deterring animals from a prey location, or by distracting them while they are trying to catch prey. So far, only limited knowledge is available on both mechanisms in the same species. The harbour porpoise (Phocoena phocoena) is a relatively small marine mammal that could quickly suffer fitness consequences from a reduction of foraging success. To investigate effects of anthropogenic sound on their foraging efficiency, we tested whether experimentally elevated sound levels would deter two captive harbour porpoises from a noisy pool into a quiet pool (Experiment 1) and reduce their prey-search performance, measured as prey-search time in the noisy pool (Experiment 2). Furthermore, we tested the influence of the temporal structure and amplitude of the sound on the avoidance response of both animals. Both individuals avoided the pool with elevated sound levels, but they did not show a change in search time for prey when trying to find a fish hidden in one of three cages. The combination of temporal structure and SPL caused variable patterns. When the sound was intermittent, increased SPL caused increased avoidance times. When the sound was continuous, avoidance was equal for all SPLs above a threshold of 100 dB re 1 μPa. Hence, we found no evidence for an effect of sound exposure on search efficiency, but sounds of different temporal patterns did cause spatial avoidance with distinct dose-response patterns. Copyright © 2017 Elsevier Ltd. All rights reserved.
Sound Exposure of Healthcare Professionals Working with a University Marching Band.
Russell, Jeffrey A; Yamaguchi, Moegi
2018-01-01
Music-induced hearing disorders are known to result from exposure to excessive levels of music of different genres. Marching band music, with its heavy emphasis on brass and percussion, is one type that is a likely contributor to music-induced hearing disorders, although specific data on sound pressure levels of marching bands have not been widely studied. Furthermore, if marching band music does lead to music-induced hearing disorders, the musicians may not be the only individuals at risk. Support personnel such as directors, equipment managers, and performing arts healthcare providers may also be exposed to potentially damaging sound pressures. Thus, we sought to explore to what degree healthcare providers receive sound dosages above recommended limits during their work with a marching band. The purpose of this study was to determine the sound exposure of healthcare professionals (specifically, athletic trainers [ATs]) who provide on-site care to a large, well-known university marching band. We hypothesized that sound pressure levels to which these individuals were exposed would exceed the National Institute for Occupational Safety and Health (NIOSH) daily percentage allowance. Descriptive observational study. Eight ATs working with a well-known American university marching band volunteered to wear noise dosimeters. During the marching band season, ATs wore an Etymotic ER-200D dosimeter whenever working with the band at outdoor rehearsals, indoor field house rehearsals, and outdoor performances. The dosimeters recorded dose percent exposure, equivalent continuous sound levels in A-weighted decibels, and duration of exposure. For comparison, a dosimeter also was worn by an AT working in the university's performing arts medicine clinic. Participants did not alter their typical duties during any data collection sessions. Sound data were collected with the dosimeters set at the NIOSH standards of 85 dBA threshold and 3 dBA exchange rate; the NIOSH 100% daily dose is an exposure to 85 dBA over 8 h. Dose data for each session were converted to a standardized dose intensity by dividing the dose percentage by the duration of the exposure and setting the NIOSH standard as a factor of 1.0. This allowed convenient relative comparisons of dose percentages of vastly different exposure durations. Analysis of variance examined relationships of noise exposures among the venues; post hoc testing was used to assess pairwise differences. As hypothesized, ATs were exposed to high sound pressure levels and dose percentages greatly exceeding those recommended by NIOSH. Higher sound levels were recorded in performance venues compared with rehearsal venues. In addition to the band music, crowd noise and public address systems contribute to high sound levels at performances. Our results suggest that healthcare providers working with marching bands are exposed to dangerous levels of sound during performances. This is especially true at venues such as football stadiums, where crowd noise and public address systems add to sound pressure. A hearing conservation program, including protection, should be required for all healthcare staff who work with marching bands. Moreover, our results should inform hearing conservation practices for marching musicians, directors, and support personnel. American Academy of Audiology
NASA Technical Reports Server (NTRS)
Johnson, Marty E.; Fuller, Chris R.; Jones, Michael G. (Technical Monitor)
2000-01-01
In this report both a frequency domain method for creating high level harmonic excitation and a time domain inverse method for creating large pulses in a duct are developed. To create controllable, high level sound an axial array of six JBL-2485 compression drivers was used. The pressure downstream is considered as input voltages to the sources filtered by the natural dynamics of the sources and the duct. It is shown that this dynamic behavior can be compensated for by filtering the inputs such that both time delays and phase changes are taken into account. The methods developed maximize the sound output while (i) keeping within the power constraints of the sources and (ii) maintaining a suitable level of reproduction accuracy. Harmonic excitation pressure levels of over 155dB were created experimentally over a wide frequency range (1000-4000Hz). For pulse excitation there is a tradeoff between accuracy of reproduction and sound level achieved. However, the accurate reproduction of a pulse with a maximum pressure level over 6500Pa was achieved experimentally. It was also shown that the throat connecting the driver to the duct makes it difficult to inject sound just below the cut-on of each acoustic mode (pre cut-on loading effect).
Predicted and Measured Modal Sound Power Levels for a Fan Ingesting Distorted Inflow
NASA Technical Reports Server (NTRS)
Koch, L. Danielle
2010-01-01
Refinements have been made to a method for estimating the modal sound power levels of a ducted fan ingesting distorted inflow. By assuming that each propagating circumferential mode consists only of a single radial mode (the one with the highest cut-off ratio), circumferential mode sound power levels can be computed for a variety of inflow distortion patterns and operating speeds. Predictions from the refined theory have been compared to data from an experiment conducted in the Advanced Noise Control Fan at NASA Glenn Research Center. The inflow to the fan was distorted by inserting cylindrical rods radially into the inlet duct. The rods were placed at an axial location one rotor chord length upstream of the fan and arranged in both regular and irregular circumferential patterns. The fan was operated at 2000, 1800, and 1400 rpm. Acoustic pressure levels were measured in the fan inlet and exhaust ducts using the Rotating Rake fan mode measurement system. Far field sound pressure levels were also measured. It is shown that predicted trends in circumferential mode sound power levels closely match the experimental data for all operating speeds and distortion configurations tested. Insight gained through this work is being used to develop more advanced tools for predicting fan inflow distortion tone noise levels.
DOE Office of Scientific and Technical Information (OSTI.GOV)
M. P. Jensen; Toto, T.
Standard Atmospheric Radiation Measurement (ARM) Climate Research Facility sounding files provide atmospheric state data in one dimension of increasing time and height per sonde launch. Many applications require a quick estimate of the atmospheric state at higher time resolution. The INTERPOLATEDSONDE (i.e., Interpolated Sounding) Value-Added Product (VAP) transforms sounding data into continuous daily files on a fixed time-height grid, at 1-minute time resolution, on 332 levels, from the surface up to a limit of approximately 40 km. The grid extends that high so the full height of soundings can be captured; however, most soundings terminate at an altitude between 25more » and 30 km, above which no data is provided. Between soundings, the VAP linearly interpolates atmospheric state variables in time for each height level. In addition, INTERPOLATEDSONDE provides relative humidity scaled to microwave radiometer (MWR) observations.« less
Where is the level of neutral buoyancy for deep convection?
NASA Astrophysics Data System (ADS)
Takahashi, Hanii; Luo, Zhengzhao
2012-08-01
This study revisits an old concept in meteorology - level of neutral buoyancy (LNB). The classic definition of LNB is derived from the parcel theory and can be estimated from the ambient sounding (LNB_sounding) without having to observe any actual convective cloud development. In reality, however, convection interacts with the environment in complicated ways; it will eventually manage to find its own effective LNB and manifests it through detraining masses and developing anvils (LNB_observation). This study conducts a near-global survey of LNB_observation for tropical deep convection using CloudSat data and makes comparison with the corresponding LNB_sounding. The principal findings are as follows: First, although LNB_sounding provides a reasonable upper bound for convective development, correlation between LNB_sounding and LNB_observation is low suggesting that ambient sounding contains limited information for accurately predicting the actual LNB. Second, maximum mass outflow is located more than 3 km lower than LNB_sounding. Hence, from convective transport perspective, LNB_sounding is a significant overestimate of the “destination” height level of the detrained mass. Third, LNB_observation is consistently higher over land than over ocean, although LNB_sounding is similar between land and ocean. This difference is likely related to the contrasts in convective strength and environment between land and ocean. Finally, we estimate the bulk entrainment rates associated with the observed deep convection, which can serve as an observational basis for adjusting GCM cumulus parameterization.
The sounds of handheld audio players.
Rudy, Susan F
2007-01-01
Hearing experts and public health organizations have longstanding hearing safety concerns about personal handheld audio devices, which are growing in both number and popularity. This paper reviews the maximum sound levels of handheld compact disc players, MP3 players, and an iPod. It further reviews device factors that influence the sound levels produced by these audio devices and ways to reduce the risk to hearing during their use.
Exploring the effect of sound and music on health in hospital settings: A narrative review.
Iyendo, Timothy Onosahwo
2016-11-01
Sound in hospital space has traditionally been considered in negative terms as both intrusive and unwanted, and based mainly on sound levels. However, sound level is only one aspect of the soundscape. There is strong evidence that exploring the positive aspect of sound in a hospital context can evoke positive feelings in both patients and nurses. Music psychology studies have also shown that music intervention in health care can have a positive effect on patient's emotions and recuperating processes. In this way, hospital spaces have the potential to reduce anxiety and stress, and make patients feel comfortable and secure. This paper describes a review of the literature exploring sound perception and its effect on health care. This review sorted the literature and main issues into themes concerning sound in health care spaces; sound, stress and health; positive soundscape; psychological perspective of music and emotion; music as a complementary medicine for improving health care; contradicting arguments concerning the use of music in health care; and implications for clinical practice. Using Web of Science, PubMed, Scopus, ProQuest Central, MEDLINE, and Google, a literature search on sound levels, sound sources and the impression of a soundscape was conducted. The review focused on the role and use of music on health care in clinical environments. In addition, other pertinent related materials in shaping the understanding of the field were retrieved, scanned and added into this review. The result indicated that not all noises give a negative impression within healthcare soundscapes. Listening to soothing music was shown to reduce stress, blood pressure and post-operative trauma when compared to silence. Much of the sound conveys meaningful information that is positive for both patients and nurses, in terms of soft wind, bird twitter, and ocean sounds. Music perception was demonstrated to bring about positive change in patient-reported outcomes such as eliciting positive emotion, and decreasing the levels of stressful conditions. Whilst sound holds both negative and positive aspects of the hospital ecosystem and may be stressful, it also possesses a soothing quality that induces positive feelings in patients. Conceptualizing the nature of sound in the hospital context as a soundscape, rather than merely noise can permit a subtler and socially useful understanding of the role of sound and music in the hospital setting, thereby creating a means for improving the hospital experience for patients and nurses. Copyright © 2016 Elsevier Ltd. All rights reserved.
Stapes Displacement and Intracochlear Pressure in Response to Very High Level, Low Frequency Sounds
Greene, Nathaniel T.; Jenkins, Herman A.; Tollin, Daniel J.; Easter, James R.
2018-01-01
The stapes is held in the oval window by the stapedial annular ligament (SAL), which restricts total peak-to-peak displacement of the stapes. Previous studies have suggested that for moderate (< 130 dB SPL) sound levels intracochlear pressure (PIC), measured at the base of the cochlea far from the basilar membrane, increases directly proportionally with stapes displacement (DStap), thus a current model of impulse noise exposure (the Auditory Hazard Assessment Algorithm for Humans, or AHAAH) predicts that peak PIC will vary linearly with DStap up to some saturation point. However, no direct tests of DStap, or of the relationship with PIC during such motion, have been performed during acoustic stimulation of the human ear. In order to examine the relationship between DStap and PIC to very high level sounds, measurements of DStap and PIC were made in cadaveric human temporal bones. Specimens were prepared by mastoidectomy and extended facial recess to expose the ossicular chain. Measurements of PIC were made in scala vestibuli (PSV) and scala tympani (PST), along with the SPL in the external auditory canal (PEAC), concurrently with laser Doppler vibrometry (LDV) measurements of stapes velocity (VStap). Stimuli were moderate (~100 dB SPL) to very high level (up to ~170 dB SPL), low frequency tones (20–2560 Hz). Both DStap and PSV increased proportionally with sound pressure level in the ear canal up to approximately ~150 dB SPL, above which both DStap and PSV showed a distinct deviation from proportionality with PEAC. Both DStap and PSV approached saturation: DStap at a value exceeding 150 μm, which is substantially higher than has been reported for small mammals, while PSV showed substantial frequency dependence in the saturation point. The relationship between PSV and DStap remained constant, and cochlear input impedance did not vary across the levels tested, consistent with prior measurements at lower sound levels. These results suggest that PSV sound pressure holds constant relationship with DStap, described by the cochlear input impedance, at these, but perhaps not higher, stimulation levels. Additionally, these results indicate that the AHAAH model, which was developed using results from small animals, underestimates the sound pressure levels in the cochlea in response to high level sound stimulation, and must be revised. PMID:28189837
An analysis of collegiate band directors' exposure to sound pressure levels
NASA Astrophysics Data System (ADS)
Roebuck, Nikole Moore
Noise-induced hearing loss (NIHL) is a significant but unfortunate common occupational hazard. The purpose of the current study was to measure the magnitude of sound pressure levels generated within a collegiate band room and determine if those sound pressure levels are of a magnitude that exceeds the policy standards and recommendations of the Occupational Safety and Health Administration (OSHA), and the National Institute of Occupational Safety and Health (NIOSH). In addition, reverberation times were measured and analyzed in order to determine the appropriateness of acoustical conditions for the band rehearsal environment. Sound pressure measurements were taken from the rehearsal of seven collegiate marching bands. Single sample t test were conducted to compare the sound pressure levels of all bands to the noise exposure standards of OSHA and NIOSH. Multiple regression analysis were conducted and analyzed in order to determine the effect of the band room's conditions on the sound pressure levels and reverberation times. Time weighted averages (TWA), noise percentage doses, and peak levels were also collected. The mean Leq for all band directors was 90.5 dBA. The total accumulated noise percentage dose for all band directors was 77.6% of the maximum allowable daily noise dose under the OSHA standard. The total calculated TWA for all band directors was 88.2% of the maximum allowable daily noise dose under the OSHA standard. The total accumulated noise percentage dose for all band directors was 152.1% of the maximum allowable daily noise dose under the NIOSH standards, and the total calculated TWA for all band directors was 93dBA of the maximum allowable daily noise dose under the NIOSH standard. Multiple regression analysis revealed that the room volume, the level of acoustical treatment and the mean room reverberation time predicted 80% of the variance in sound pressure levels in this study.
Examining INM Accuracy Using Empirical Sound Monitoring and Radar Data
NASA Technical Reports Server (NTRS)
Miller, Nicholas P.; Anderson, Grant S.; Horonjeff, Richard D.; Kimura, Sebastian; Miller, Jonathan S.; Senzig, David A.; Thompson, Richard H.; Shepherd, Kevin P. (Technical Monitor)
2000-01-01
Aircraft noise measurements were made using noise monitoring systems at Denver International and Minneapolis St. Paul Airports. Measured sound exposure levels for a large number of operations of a wide range of aircraft types were compared with predictions using the FAA's Integrated Noise Model. In general it was observed that measured levels exceeded the predicted levels by a significant margin. These differences varied according to the type of aircraft and also depended on the distance from the aircraft. Many of the assumptions which affect the predicted sound levels were examined but none were able to fully explain the observed differences.
Khajenasiri, Farahnaz; Zamanian, Alireza; Zamanian, Zahra
2016-03-01
Sound is among the significant environmental factors for people's health, and it has an important role in both physical and psychological injuries, and it also affects individuals' performance and productivity. The aim of this study was to determine the effect of exposure to high noise levels on the performance and rate of error in manual activities. This was an interventional study conducted on 50 students at Shiraz University of Medical Sciences (25 males and 25 females) in which each person was considered as its own control to assess the effect of noise on her or his performance at the sound levels of 70, 90, and 110 dB by using two factors of physical features and the creation of different conditions of sound source as well as applying the Two-Arm coordination Test. The data were analyzed using SPSS version 16. Repeated measurements were used to compare the length of performance as well as the errors measured in the test. Based on the results, we found a direct and significant association between the levels of sound and the length of performance. Moreover, the participant's performance was significantly different for different sound levels (at 110 dB as opposed to 70 and 90 dB, p < 0.05 and p < 0.001, respectively). This study found that a sound level of 110 dB had an important effect on the individuals' performances, i.e., the performances were decreased.
Audio spectrum and sound pressure levels vary between pulse oximeters.
Chandra, Deven; Tessler, Michael J; Usher, John
2006-01-01
The variable-pitch pulse oximeter is an important intraoperative patient monitor. Our ability to hear its auditory signal depends on its acoustical properties and our hearing. This study quantitatively describes the audio spectrum and sound pressure levels of the monitoring tones produced by five variable-pitch pulse oximeters. We compared the Datex-Ohmeda Capnomac Ultima, Hewlett-Packard M1166A, Datex-Engstrom AS/3, Ohmeda Biox 3700, and Datex-Ohmeda 3800 oximeters. Three machines of each of the five models were assessed for sound pressure levels (using a precision sound level meter) and audio spectrum (using a hanning windowed fast Fourier trans-form of three beats at saturations of 99%, 90%, and 85%). The widest range of sound pressure levels was produced by the Hewlett-Packard M1166A (46.5 +/- 1.74 dB to 76.9 +/- 2.77 dB). The loudest model was the Datex-Engstrom AS/3 (89.2 +/- 5.36 dB). Three oximeters, when set to the lower ranges of their volume settings, were indistinguishable from background operating room noise. Each model produced sounds with different audio spectra. Although each model produced a fundamental tone with multiple harmonic overtones, the number of harmonics varied with each model; from three harmonic tones on the Hewlett-Packard M1166A, to 12 on the Ohmeda Biox 3700. There were variations between models, and individual machines of the same model with respect to the fundamental tone associated with a given saturation. There is considerable variance in the sound pressure and audio spectrum of commercially-available pulse oximeters. Further studies are warranted in order to establish standards.
Development of a Novel Noise Delivery System for JP-8 Ototoxicity Studies
2010-03-01
kHz. The authors indicated that at the time of the article they were not aware of any other studies that investigated simultaneous exposure to...Sound Study.” 4.4 The audiology sound program will be loaded which allows creation of the correct sound levels. 5.0 CREATING SOUND AND COLLECTING
Perceptual constancy in auditory perception of distance to railway tracks.
De Coensel, Bert; Nilsson, Mats E; Berglund, Birgitta; Brown, A L
2013-07-01
Distance to a sound source can be accurately estimated solely from auditory information. With a sound source such as a train that is passing by at a relatively large distance, the most important auditory information for the listener for estimating its distance consists of the intensity of the sound, spectral changes in the sound caused by air absorption, and the motion-induced rate of change of intensity. However, these cues are relative because prior information/experience of the sound source-its source power, its spectrum and the typical speed at which it moves-is required for such distance estimates. This paper describes two listening experiments that allow investigation of further prior contextual information taken into account by listeners-viz., whether they are indoors or outdoors. Asked to estimate the distance to the track of a railway, it is shown that listeners assessing sounds heard inside the dwelling based their distance estimates on the expected train passby sound level outdoors rather than on the passby sound level actually experienced indoors. This form of perceptual constancy may have consequences for the assessment of annoyance caused by railway noise.
Keefe, Douglas H.; Schairer, Kim S.
2011-01-01
An insert ear-canal probe including sound source and microphone can deliver a calibrated sound power level to the ear. The aural power absorbed is proportional to the product of mean-squared forward pressure, ear-canal area, and absorbance, in which the sound field is represented using forward (reverse) waves traveling toward (away from) the eardrum. Forward pressure is composed of incident pressure and its multiple internal reflections between eardrum and probe. Based on a database of measurements in normal-hearing adults from 0.22 to 8 kHz, the transfer-function level of forward relative to incident pressure is boosted below 0.7 kHz and within 4 dB above. The level of forward relative to total pressure is maximal close to 4 kHz with wide variability across ears. A spectrally flat incident-pressure level across frequency produces a nearly flat absorbed power level, in contrast to 19 dB changes in pressure level. Calibrating an ear-canal sound source based on absorbed power may be useful in audiological and research applications. Specifying the tip-to-tail level difference of the suppression tuning curve of stimulus frequency otoacoustic emissions in terms of absorbed power reveals increased cochlear gain at 8 kHz relative to the level difference measured using total pressure. PMID:21361437
Chen, Xuhai; Yang, Jianfeng; Gan, Shuzhen; Yang, Yufang
2012-01-01
Although its role is frequently stressed in acoustic profile for vocal emotion, sound intensity is frequently regarded as a control parameter in neurocognitive studies of vocal emotion, leaving its role and neural underpinnings unclear. To investigate these issues, we asked participants to rate the angry level of neutral and angry prosodies before and after sound intensity modification in Experiment 1, and recorded electroencephalogram (EEG) for mismatching emotional prosodies with and without sound intensity modification and for matching emotional prosodies while participants performed emotional feature or sound intensity congruity judgment in Experiment 2. It was found that sound intensity modification had significant effect on the rating of angry level for angry prosodies, but not for neutral ones. Moreover, mismatching emotional prosodies, relative to matching ones, induced enhanced N2/P3 complex and theta band synchronization irrespective of sound intensity modification and task demands. However, mismatching emotional prosodies with reduced sound intensity showed prolonged peak latency and decreased amplitude in N2/P3 complex and smaller theta band synchronization. These findings suggest that though it cannot categorically affect emotionality conveyed in emotional prosodies, sound intensity contributes to emotional significance quantitatively, implying that sound intensity should not simply be taken as a control parameter and its unique role needs to be specified in vocal emotion studies.
Chen, Xuhai; Yang, Jianfeng; Gan, Shuzhen; Yang, Yufang
2012-01-01
Although its role is frequently stressed in acoustic profile for vocal emotion, sound intensity is frequently regarded as a control parameter in neurocognitive studies of vocal emotion, leaving its role and neural underpinnings unclear. To investigate these issues, we asked participants to rate the angry level of neutral and angry prosodies before and after sound intensity modification in Experiment 1, and recorded electroencephalogram (EEG) for mismatching emotional prosodies with and without sound intensity modification and for matching emotional prosodies while participants performed emotional feature or sound intensity congruity judgment in Experiment 2. It was found that sound intensity modification had significant effect on the rating of angry level for angry prosodies, but not for neutral ones. Moreover, mismatching emotional prosodies, relative to matching ones, induced enhanced N2/P3 complex and theta band synchronization irrespective of sound intensity modification and task demands. However, mismatching emotional prosodies with reduced sound intensity showed prolonged peak latency and decreased amplitude in N2/P3 complex and smaller theta band synchronization. These findings suggest that though it cannot categorically affect emotionality conveyed in emotional prosodies, sound intensity contributes to emotional significance quantitatively, implying that sound intensity should not simply be taken as a control parameter and its unique role needs to be specified in vocal emotion studies. PMID:22291928
Bevelhimer, Mark S; Deng, Z Daniel; Scherelis, Constantin
2016-01-01
Underwater noise associated with the installation and operation of hydrokinetic turbines in rivers and tidal zones presents a potential environmental concern for fish and marine mammals. Comparing the spectral quality of sounds emitted by hydrokinetic turbines to natural and other anthropogenic sound sources is an initial step at understanding potential environmental impacts. Underwater recordings were obtained from passing vessels and natural underwater sound sources in static and flowing waters. Static water measurements were taken in a lake with minimal background noise. Flowing water measurements were taken at a previously proposed deployment site for hydrokinetic turbines on the Mississippi River, where sounds created by flowing water are part of all measurements, both natural ambient and anthropogenic sources. Vessel sizes ranged from a small fishing boat with 60 hp outboard motor to an 18-unit barge train being pushed upstream by tugboat. As expected, large vessels with large engines created the highest sound levels, which were, on average, 40 dB greater than the sound created by an operating hydrokinetic turbine. A comparison of sound levels from the same sources at different distances using both spherical and cylindrical sound attenuation functions suggests that spherical model results more closely approximate observed sound attenuation.
Almadhoob, Abdulraoof; Ohlsson, Arne
2015-01-30
Infants in the neonatal intensive care unit (NICU) are subjected to stress, including sound of high intensity. The sound environment in the NICU is louder than most home or office environments and contains disturbing noises of short duration and at irregular intervals. There are competing auditory signals that frequently challenge preterm infants, staff and parents. The sound levels in NICUs often exceed the maximum acceptable level of 45 decibels (dB), recommended by the American Academy of Pediatrics. Hearing impairment is diagnosed in 2% to 10% of preterm infants versus 0.1% of the general paediatric population. Noise may cause apnoea, hypoxaemia, alternation in oxygen saturation, and increased oxygen consumption secondary to elevated heart and respiratory rates and may, therefore, decrease the amount of calories available for growth. Elevated levels of speech are needed to overcome the noisy environment in the NICU, thereby increasing the negative impacts on staff, newborns, and their families. High noise levels are associated with an increased rate of errors and accidents, leading to decreased performance among staff. The aim of interventions included in this review is to reduce sound levels to 45 dB or less. This can be achieved by lowering the sound levels in an entire unit, treating the infant in a section of a NICU, in a 'private' room, or in incubators in which the sound levels are controlled, or reducing the sound levels that reaches the individual infant by using earmuffs or earplugs. By lowering the sound levels that reach the neonate, the resulting stress on the cardiovascular, respiratory, neurological, and endocrine systems can be diminished, thereby promoting growth and reducing adverse neonatal outcomes. Primary objectiveTo determine the effects of sound reduction on growth and long-term neurodevelopmental outcomes of neonates. Secondary objectives1. To evaluate the effects of sound reduction on short-term medical outcomes (bronchopulmonary dysplasia, intraventricular haemorrhage, periventricular leukomalacia, retinopathy of prematurity).2. To evaluate the effects of sound reduction on sleep patterns at three months of age.3. To evaluate the effects of sound reduction on staff performance.4. To evaluate the effects of sound reduction in the neonatal intensive care unit (NICU) on parents' satisfaction with the care. We searched the Cochrane Central Register of Controlled Trials (The Cochrane Library), MEDLINE, EMBASE, CINAHL, abstracts from scientific meetings, clinical trials registries (clinicaltrials.gov; controlled-trials.com; and who.int/ictrp), Pediatric Academic Societies Annual meetings 2000 to 2014 (Abstracts2View(TM)), reference lists of identified trials, and reviews to November 2014. Preterm infants (< 32 weeks' postmenstrual age (PMA) or < 1500 g birth weight) cared for in the resuscitation area, during transport, or once admitted to a NICU or a stepdown unit. We performed data collection and analyses according to the Cochrane Neonatal Review Group. One small, high quality study assessing the effects of silicone earplugs versus no earplugs qualified for inclusion. The original inclusion criteria in our protocol stipulated an age of < 48 hours at the time of initiating sound reduction. We made a deviation from our protocol and included this study in which some infants would have been > 48 hours old. There was no significant difference in weight at 34 weeks postmenstrual age (PMA): mean difference (MD) 111 g (95% confidence interval (CI) -151 to 374 g) (n = 23). There was no significant difference in weight at 18 to 22 months corrected age between the groups: MD 0.31 kg, 95% CI -1.53 to 2.16 kg (n = 14). There was a significant difference in Mental Developmental Index (Bayley II) favouring the silicone earplugs group at 18 to 22 months corrected age: MD 14.00, 95% CI 3.13 to 24.87 (n = 12), but not for Psychomotor Development Index (Bayley II) at 18 to 22 months corrected age: MD -2.16, 95% CI -18.44 to 14.12 (n =12). To date, only 34 infants have been enrolled in a randomised controlled trial (RCT) testing the effectiveness of reducing sound levels that reach the infants' ears in the NICU. Based on the small sample size of this single trial, we cannot make any recommendations for clinical practice. Larger, well designed, conducted and reported trials are needed.
Code of Federal Regulations, 2010 CFR
2010-10-01
... remanufactured; or (2) The motor vehicle generates a maximum sound level reading of 90 dB(A) or less when... (35 mph). (iv) The sound level measurement must be made while the motor vehicle is operating at the...
Code of Federal Regulations, 2011 CFR
2011-10-01
... remanufactured; or (2) The motor vehicle generates a maximum sound level reading of 90 dB(A) or less when... (35 mph). (iv) The sound level measurement must be made while the motor vehicle is operating at the...
Murphy, William J; Flamme, Gregory A; Campbell, Adam R; Zechmann, Edward L; Tasko, Stephen M; Lankford, James E; Meinke, Deanna K; Finan, Donald S; Stewart, Michael
2018-02-01
This research assessed the reduction of peak levels, equivalent energy and sound power of firearm suppressors. The first study evaluated the effect of three suppressors at four microphone positions around four firearms. The second study assessed the suppressor-related reduction of sound power with a 3 m hemispherical microphone array for two firearms. The suppressors reduced exposures at the ear between 17 and 24 dB peak sound pressure level and reduced the 8 h equivalent A-weighted energy between 9 and 21 dB depending upon the firearm and ammunition. Noise reductions observed for the instructor's position about a metre behind the shooter were between 20 and 28 dB peak sound pressure level and between 11 and 26 dB L Aeq,8h . Firearm suppressors reduced the measured sound power levels between 2 and 23 dB. Sound power reductions were greater for the low-velocity ammunition than for the same firearms fired with high-velocity ammunition due to the effect of N-waves produced by a supersonic bullet. Firearm suppressors may reduce noise exposure, and the cumulative exposures of suppressed firearms can still present a significant hearing risk. Therefore, firearm users should always wear hearing protection whenever target shooting or hunting.
Effects of exposure to pile-driving sounds on the lake sturgeon, Nile tilapia and hogchoker
Halvorsen, Michele B.; Casper, Brandon M.; Matthews, Frazer; Carlson, Thomas J.; Popper, Arthur N.
2012-01-01
Pile-driving and other impulsive sound sources have the potential to injure or kill fishes. One mechanism that produces injuries is the rapid motion of the walls of the swim bladder as it repeatedly contacts nearby tissues. To further understand the involvement of the swim bladder in tissue damage, a specially designed wave tube was used to expose three species to pile-driving sounds. Species included lake sturgeon (Acipenser fulvescens)—with an open (physostomous) swim bladder, Nile tilapia (Oreochromis niloticus)—with a closed (physoclistous) swim bladder and the hogchoker (Trinectes maculatus)—a flatfish without a swim bladder. There were no visible injuries in any of the exposed hogchokers, whereas a variety of injuries were observed in the lake sturgeon and Nile tilapia. At the loudest cumulative and single-strike sound exposure levels (SELcum and SELss respectively), the Nile tilapia had the highest total injuries and the most severe injuries per fish. As exposure levels decreased, the number and severity of injuries were more similar between the two species. These results suggest that the presence and type of swim bladder correlated with injury at higher sound levels, while the extent of injury at lower sound levels was similar for both kinds of swim bladders. PMID:23055066
Effects of exposure to pile-driving sounds on the lake sturgeon, Nile tilapia and hogchoker.
Halvorsen, Michele B; Casper, Brandon M; Matthews, Frazer; Carlson, Thomas J; Popper, Arthur N
2012-12-07
Pile-driving and other impulsive sound sources have the potential to injure or kill fishes. One mechanism that produces injuries is the rapid motion of the walls of the swim bladder as it repeatedly contacts nearby tissues. To further understand the involvement of the swim bladder in tissue damage, a specially designed wave tube was used to expose three species to pile-driving sounds. Species included lake sturgeon (Acipenser fulvescens)--with an open (physostomous) swim bladder, Nile tilapia (Oreochromis niloticus)--with a closed (physoclistous) swim bladder and the hogchoker (Trinectes maculatus)--a flatfish without a swim bladder. There were no visible injuries in any of the exposed hogchokers, whereas a variety of injuries were observed in the lake sturgeon and Nile tilapia. At the loudest cumulative and single-strike sound exposure levels (SEL(cum) and SEL(ss) respectively), the Nile tilapia had the highest total injuries and the most severe injuries per fish. As exposure levels decreased, the number and severity of injuries were more similar between the two species. These results suggest that the presence and type of swim bladder correlated with injury at higher sound levels, while the extent of injury at lower sound levels was similar for both kinds of swim bladders.
Time frequency analysis of sound from a maneuvering rotorcraft
NASA Astrophysics Data System (ADS)
Stephenson, James H.; Tinney, Charles E.; Greenwood, Eric; Watts, Michael E.
2014-10-01
The acoustic signatures produced by a full-scale, Bell 430 helicopter during steady-level-flight and transient roll-right maneuvers are analyzed by way of time-frequency analysis. The roll-right maneuvers comprise both a medium and a fast roll rate. Data are acquired using a single ground based microphone that are analyzed by way of the Morlet wavelet transform to extract the spectral properties and sound pressure levels as functions of time. The findings show that during maneuvering operations of the helicopter, both the overall sound pressure level and the blade-vortex interaction sound pressure level are greatest when the roll rate of the vehicle is at its maximum. The reduced inflow in the region of the rotor disk where blade-vortex interaction noise originates is determined to be the cause of the increase in noise. A local decrease in inflow reduces the miss distance of the tip vortex and thereby increases the BVI noise signature. Blade loading and advance ratios are also investigated as possible mechanisms for increased sound production, but are shown to be fairly constant throughout the maneuvers.
Spatial traffic noise pollution assessment - A case study.
Monazzam, Mohammad Reza; Karimi, Elham; Abbaspour, Majid; Nassiri, Parvin; Taghavi, Lobat
2015-01-01
Spatial assessment of traffic noise pollution intensity will provide urban planners with approximate estimation of citizens exposure to impermissible sound levels. They could identify critical noise pollution areas wherein noise barriers should be embedded. The present study aims at using the Geographic Information System (GIS) to assess spatial changes in traffic noise pollution in Tehran, the capital of Iran, and the largest city in the Middle East. For this purpose, while measuring equivalent sound levels at different time periods of a day and different days of a week in District 14 of Tehran, wherein there are highways and busy streets, the geographic coordination of the measurement points was recorded at the stations. The obtained results indicated that the equivalent sound level did not show a statistically significant difference between weekdays, and morning, afternoon and evening hours as well as time intervals of 10 min, 15 min and 30 min. Then, 91 stations were selected in the target area and equivalent sound level was measured for each station on 3 occasions of the morning (7:00-9:00 a.m.), afternoon (12.00-3:00 p.m.) and evening (5:00-8:00 p.m.) on Saturdays to Wednesdays. As the results suggest, the maximum equivalent sound level (Leq) was reported from Basij Highway, which is a very important connecting thoroughfare in the district, and was equal to 84.2 dB(A), while the minimum equivalent sound level (Leq), measured in the Fajr Hospital, was equal to 59.9 dB(A). The average equivalent sound level was higher than the national standard limit at all stations. The use of sound walls in Highways Basij and Mahallati as well as widening the Streets 17th Shahrivar, Pirouzi and Khavaran, benchmarked on a map, were recommended as the most effective mitigation measures. Additionally, the research findings confirm the outstanding applicability of the Geographic Information System in handling noise pollution data towards depicting noise pollution intensity caused by traffic. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.
Application of acoustic radiosity methods to noise propagation within buildings
NASA Astrophysics Data System (ADS)
Muehleisen, Ralph T.; Beamer, C. Walter
2005-09-01
The prediction of sound pressure levels in rooms from transmitted sound is a difficult problem. The sound energy in the source room incident on the common wall must be accurately predicted. In the receiving room, the propagation of sound from the planar wall source must also be accurately predicted. The radiosity method naturally computes the spatial distribution of sound energy incident on a wall and also naturally predicts the propagation of sound from a planar area source. In this paper, the application of the radiosity method to sound transmission problems is introduced and explained.
Indoor noise annoyance due to 3-5 megawatt wind turbines-An exposure-response relationship.
Hongisto, Valtteri; Oliva, David; Keränen, Jukka
2017-10-01
The existing exposure-response relationships describing the association between wind turbine sound level and noise annoyance concern turbine sizes of 0.15-3.0 MW. The main purpose of this study was to determine a relationship concerning turbines with nominal power of 3-5 MW. A cross-sectional survey was conducted around three wind power areas in Finland. The survey involved all households within a 2 km distance from the nearest turbine. Altogether, 429 households out of 753 participated. The households were exposed to wind turbine noise having sound levels within 26.7-44.2 dB L Aeq . Standard prediction methods were applied to determine the sound level, L Aeq , in each participant's yard. The measured sound level agreed well with the predicted sound level. The exposure-response relationship was derived between L Aeq outdoors and the indoor noise annoyance. The relationship was in rather good agreement with two previous studies involving much smaller turbines (0.15-1.5 MW) under 40 dB L Aeq . The Community Tolerance Level (CTL), CTL 20 = 50 dB, was 3 dB lower than for two previous studies. Above 40 dB, a small number of participants prevented a reliable comparison to previous studies.
Ooishi, Yuuki
2018-01-01
A sound-induced sympathetic tone has been used as an index for orienting responses to auditory stimuli. The resting testosterone/cortisol ratio is a biomarker of social aggression that drives an approaching behavior in response to environmental stimuli, and a higher testosterone level and a lower cortisol level can facilitate the sympathetic response to environmental stimuli. Therefore, it is possible that the testosterone/cortisol ratio is correlated with the sound-induced sympathetic tone. The current study investigated the relationship between the resting testosterone/cortisol ratio and vasoconstriction induced by listening to sound stimuli. Twenty healthy males aged 29.0 ± 0.53 years (mean ± S.E.M) participated in the study. They came to the laboratory for 3 days and listened to one of three types of sound stimuli for 1 min on each day. Saliva samples were collected for an analysis of salivary testosterone and cortisol levels on the day of each experiment. After the collecting the saliva sample, we measured the blood volume pulse (BVP) amplitude at a fingertip. Since vasoconstriction is mediated by the activation of the sympathetic nerves, the strength of the reduction in BVP amplitude at a fingertip was called the BVP response (finger BVPR). No difference was observed between the sound-induced finger BVPR for the three types of sound stimuli (p = 0.779). The correlation coefficient between the sound-induced finger BVPR and the salivary testosterone/cortisol ratio within participants was significantly different from no correlation (p = 0.011) and there was a trend toward a significance in the correlation between the sound-induced finger BVPR and the salivary testosterone/cortisol ratio between participants (r = 0.39, p = 0.088). These results suggest that the testosterone/cortisol ratio affects the difference in the sound-evoked sympathetic response. PMID:29559922
Ooishi, Yuuki
2018-01-01
A sound-induced sympathetic tone has been used as an index for orienting responses to auditory stimuli. The resting testosterone/cortisol ratio is a biomarker of social aggression that drives an approaching behavior in response to environmental stimuli, and a higher testosterone level and a lower cortisol level can facilitate the sympathetic response to environmental stimuli. Therefore, it is possible that the testosterone/cortisol ratio is correlated with the sound-induced sympathetic tone. The current study investigated the relationship between the resting testosterone/cortisol ratio and vasoconstriction induced by listening to sound stimuli. Twenty healthy males aged 29.0 ± 0.53 years (mean ± S.E.M) participated in the study. They came to the laboratory for 3 days and listened to one of three types of sound stimuli for 1 min on each day. Saliva samples were collected for an analysis of salivary testosterone and cortisol levels on the day of each experiment. After the collecting the saliva sample, we measured the blood volume pulse (BVP) amplitude at a fingertip. Since vasoconstriction is mediated by the activation of the sympathetic nerves, the strength of the reduction in BVP amplitude at a fingertip was called the BVP response (finger BVPR). No difference was observed between the sound-induced finger BVPR for the three types of sound stimuli ( p = 0.779). The correlation coefficient between the sound-induced finger BVPR and the salivary testosterone/cortisol ratio within participants was significantly different from no correlation ( p = 0.011) and there was a trend toward a significance in the correlation between the sound-induced finger BVPR and the salivary testosterone/cortisol ratio between participants ( r = 0.39, p = 0.088). These results suggest that the testosterone/cortisol ratio affects the difference in the sound-evoked sympathetic response.
Callback response of dugongs to conspecific chirp playbacks.
Ichikawa, Kotaro; Akamatsu, Tomonari; Shinke, Tomio; Adulyanukosol, Kanjana; Arai, Nobuaki
2011-06-01
Dugongs (Dugong dugon) produce bird-like calls such as chirps and trills. The vocal responses of dugongs to playbacks of several acoustic stimuli were investigated. Animals were exposed to four different playback stimuli: a recorded chirp from a wild dugong, a synthesized down-sweep sound, a synthesized constant-frequency sound, and silence. Wild dugongs vocalized more frequently after playback of broadcast chirps than that after constant-frequency sounds or silence. The down-sweep sound also elicited more vocal responses than did silence. No significant difference was found between the broadcast chirps and the down-sweep sound. The ratio of wild dugong chirps to all calls and the dominant frequencies of the wild dugong calls were significantly higher during playbacks of broadcast chirps, down-sweep sounds, and constant-frequency sounds than during those of silence. The source level and duration of dugong chirps increased significantly as signaling distance increased. No significant correlation was found between signaling distance and the source level of trills. These results show that dugongs vocalize to playbacks of frequency-modulated signals and suggest that the source level of dugong chirps may be manipulated to compensate for transmission loss between the source and receiver. This study provides the first behavioral observations revealing the function of dugong chirps. © 2011 Acoustical Society of America
Digital PIV Measurements of Acoustic Particle Displacements in a Normal Incidence Impedance Tube
NASA Technical Reports Server (NTRS)
Humphreys, William M., Jr.; Bartram, Scott M.; Parrott, Tony L.; Jones, Michael G.
1998-01-01
Acoustic particle displacements and velocities inside a normal incidence impedance tube have been successfully measured for a variety of pure tone sound fields using Digital Particle Image Velocimetry (DPIV). The DPIV system utilized two 600-mj Nd:YAG lasers to generate a double-pulsed light sheet synchronized with the sound field and used to illuminate a portion of the oscillatory flow inside the tube. A high resolution (1320 x 1035 pixel), 8-bit camera was used to capture double-exposed images of 2.7-micron hollow silicon dioxide tracer particles inside the tube. Classical spatial autocorrelation analysis techniques were used to ascertain the acoustic particle displacements and associated velocities for various sound field intensities and frequencies. The results show that particle displacements spanning a range of 1-60 microns can be measured for incident sound pressure levels of 100-130 dB and for frequencies spanning 500-1000 Hz. The ability to resolve 1 micron particle displacements at sound pressure levels in the 100 dB range allows the use of DPIV systems for measurement of sound fields at much lower sound pressure levels than had been previously possible. Representative impedance tube data as well as an uncertainty analysis for the measurements are presented.
Kastelein, R A; Verboom, W C; Muijsers, M; Jennings, N V; van der Heul, S
2005-05-01
To prevent grounding of ships and collisions between ships in shallow coastal waters, an underwater data collection and communication network is currently under development: Acoustic Communication network for Monitoring of underwater Environment in coastal areas (ACME). Marine mammals might be affected by ACME sounds since they use sounds of similar frequencies (around 12 kHz) for communication, orientation, and prey location. If marine mammals tend to avoid the vicinity of the transmitters, they may be kept away from ecologically important areas by ACME sounds. One marine mammal species that may be affected in the North Sea is the harbour porpoise. Therefore, as part of an environmental impact assessment program, two captive harbour porpoises were subjected to four sounds, three of which may be used in the underwater acoustic data communication network. The effect of each sound was judged by comparing the animals' positions and respiration rates during a test period with those during a baseline period. Each of the four sounds could be made a deterrent by increasing the amplitude of the sound. The porpoises reacted by swimming away from the sounds and by slightly, but significantly, increasing their respiration rate. From the sound pressure level distribution in the pen, and the distribution of the animals during test sessions, discomfort sound level thresholds were determined for each sound. In combination with information on sound propagation in the areas where the communication system may be deployed, the extent of the 'discomfort zone' can be estimated for several source levels (SLs). The discomfort zone is defined as the area around a sound source that harbour porpoises are expected to avoid. Based on these results, SLs can be selected that have an acceptable effect on harbour porpoises in particular areas. The discomfort zone of a communication sound depends on the selected sound, the selected SL, and the propagation characteristics of the area in which the sound system is operational. In shallow, winding coastal water courses, with sandbanks, etc., the type of habitat in which the ACME sounds will be produced, propagation loss cannot be accurately estimated by using a simple propagation model, but should be measured on site. The SL of the communication system should be adapted to each area (taking into account bounding conditions created by narrow channels, sound propagation variability due to environmental factors, and the importance of an area to the affected species). The discomfort zone should not prevent harbour porpoises from spending sufficient time in ecologically important areas (for instance feeding areas), or routes towards these areas.
33 CFR 86.05 - Sound signal intensity and range of audibility.
Code of Federal Regulations, 2011 CFR
2011-07-01
... direction of the forward axis of the whistle and at a distance of 1 meter from it, a sound pressure level in... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Sound signal intensity and range... HOMELAND SECURITY INLAND NAVIGATION RULES ANNEX III: TECHNICAL DETAILS OF SOUND SIGNAL APPLIANCES Whistles...
The Problems with "Noise Numbers" for Wind Farm Noise Assessment
ERIC Educational Resources Information Center
Thorne, Bob
2011-01-01
Human perception responds primarily to sound character rather than sound level. Wind farms are unique sound sources and exhibit special audible and inaudible characteristics that can be described as modulating sound or as a tonal complex. Wind farm compliance measures based on a specified noise number alone will fail to address problems with noise…
49 CFR 228.101 - Distance requirement; definitions.
Code of Federal Regulations, 2011 CFR
2011-10-01
... CFR 172.504). (5) The term L eq (8) shall mean the equivalent steady state sound level which in 8 hours would contain the same acoustic energy as the time-varying sound level during the same time period. ...
Evaluation of noise pollution level in the operating rooms of hospitals: A study in Iran.
Giv, Masoumeh Dorri; Sani, Karim Ghazikhanlou; Alizadeh, Majid; Valinejadi, Ali; Majdabadi, Hesamedin Askari
2017-06-01
Noise pollution in the operating rooms is one of the remaining challenges. Both patients and physicians are exposed to different sound levels during the operative cases, many of which can last for hours. This study aims to evaluate the noise pollution in the operating rooms during different surgical procedures. In this cross-sectional study, sound level in the operating rooms of Hamadan University-affiliated hospitals (totally 10) in Iran during different surgical procedures was measured using B&K sound meter. The gathered data were compared with national and international standards. Statistical analysis was performed using descriptive statistics and one-way ANOVA, t -test, and Pearson's correlation test. Noise pollution level at majority of surgical procedures is higher than national and international documented standards. The highest level of noise pollution is related to orthopedic procedures, and the lowest one related to laparoscopic and heart surgery procedures. The highest and lowest registered sound level during the operation was 93 and 55 dB, respectively. Sound level generated by equipments (69 ± 4.1 dB), trolley movement (66 ± 2.3 dB), and personnel conversations (64 ± 3.9 dB) are the main sources of noise. The noise pollution of operating rooms are higher than available standards. The procedure needs to be corrected for achieving the proper conditions.
Hearing at low and infrasonic frequencies.
Møller, H; Pedersen, C S
2004-01-01
The human perception of sound at frequencies below 200 Hz is reviewed. Knowledge about our perception of this frequency range is important, since much of the sound we are exposed to in our everyday environment contains significant energy in this range. Sound at 20-200 Hz is called low-frequency sound, while for sound below 20 Hz the term infrasound is used. The hearing becomes gradually less sensitive for decreasing frequency, but despite the general understanding that infrasound is inaudible, humans can perceive infrasound, if the level is sufficiently high. The ear is the primary organ for sensing infrasound, but at levels somewhat above the hearing threshold it is possible to feel vibrations in various parts of the body. The threshold of hearing is standardized for frequencies down to 20 Hz, but there is a reasonably good agreement between investigations below this frequency. It is not only the sensitivity but also the perceived character of a sound that changes with decreasing frequency. Pure tones become gradually less continuous, the tonal sensation ceases around 20 Hz, and below 10 Hz it is possible to perceive the single cycles of the sound. A sensation of pressure at the eardrums also occurs. The dynamic range of the auditory system decreases with decreasing frequency. This compression can be seen in the equal-loudness-level contours, and it implies that a slight increase in level can change the perceived loudness from barely audible to loud. Combined with the natural spread in thresholds, it may have the effect that a sound, which is inaudible to some people, may be loud to others. Some investigations give evidence of persons with an extraordinary sensitivity in the low and infrasonic frequency range, but further research is needed in order to confirm and explain this phenomenon.
Speaking up: Killer whales (Orcinus orca) increase their call amplitude in response to vessel noise.
Holt, Marla M; Noren, Dawn P; Veirs, Val; Emmons, Candice K; Veirs, Scott
2009-01-01
This study investigated the effects of anthropogenic sound exposure on the vocal behavior of free-ranging killer whales. Endangered Southern Resident killer whales inhabit areas including the urban coastal waters of Puget Sound near Seattle, WA, where anthropogenic sounds are ubiquitous, particularly those from motorized vessels. A calibrated recording system was used to measure killer whale call source levels and background noise levels (1-40 kHz). Results show that whales increased their call amplitude by 1 dB for every 1 dB increase in background noise levels. Furthermore, nearby vessel counts were positively correlated with these observed background noise levels.
DOT National Transportation Integrated Search
2002-01-31
Accurate modeling of the lateral attenuation of sound is : essential for accurate prediction of aircraft noise. Lateral : attenuation contains many aspects of sound generation and : propagation, including ground effects (sometimes referred to :...
NASA Astrophysics Data System (ADS)
Matetic, Rudy J.
Over-exposure to noise remains a widespread and serious health hazard in the U.S. mining industries despite 25 years of regulation. Every day, 80% of the nation's miners go to work in an environment where the time weighted average (TWA) noise level exceeds 85 dBA and more than 25% of the miners are exposed to a TWA noise level that exceeds 90 dBA, the permissible exposure limit (PEL). Additionally, MSHA coal noise sample data collected from 2000 to 2002 show that 65% of the equipment whose operators exceeded 100% noise dosage comprise only seven different types of machines; auger miners, bulldozers, continuous miners, front end loaders, roof bolters, shuttle cars (electric), and trucks. In addition, the MSHA data indicate that the roof bolter is third among all the equipment and second among equipment in underground coal whose operators exceed 100% dosage. A research program was implemented to: (1) determine, characterize and to measure sound power levels radiated by a roof bolting machine during differing drilling configurations (thrust, rotational speed, penetration rate, etc.) and utilizing differing types of drilling methods in high compressive strength rock media (>20,000 psi). The research approach characterized the sound power level results from laboratory testing and provided the mining industry with empirical data relative to utilizing differing noise control technologies (drilling configurations and types of drilling methods) in reducing sound power level emissions on a roof bolting machine; (2) distinguish and correlate the empirical data into one, statistically valid, equation, in which, provided the mining industry with a tool to predict overall sound power levels of a roof bolting machine given any type of drilling configuration and drilling method utilized in industry; (3) provided the mining industry with several approaches to predict or determine sound pressure levels in an underground coal mine utilizing laboratory test results from a roof bolting machine and (4) described a method for determining an operators' noise dosage of a roof bolting machine utilizing predicted or determined sound pressure levels.
Sound absorption coefficient of coal bottom ash concrete for railway application
NASA Astrophysics Data System (ADS)
Ramzi Hannan, N. I. R.; Shahidan, S.; Maarof, Z.; Ali, N.; Abdullah, S. R.; Ibrahim, M. H. Wan
2017-11-01
A porous concrete able to reduce the sound wave that pass through it. When a sound waves strike a material, a portion of the sound energy was reflected back and another portion of the sound energy was absorbed by the material while the rest was transmitted. The larger portion of the sound wave being absorbed, the lower the noise level able to be lowered. This study is to investigate the sound absorption coefficient of coal bottom ash (CBA) concrete compared to the sound absorption coefficient of normal concrete by carried out the impedance tube test. Hence, this paper presents the result of the impedance tube test of the CBA concrete and normal concrete.
An evaluation of Space Shuttle STS-2 payload bay acoustic data and comparison with predictions
NASA Technical Reports Server (NTRS)
Wilby, J. F.; Piersol, A. G.; Wilby, E. G.
1982-01-01
Space average sound pressure levels computed from measurements at 18 locations in the payload bay of the Space Shuttle orbiter vehicle during the STS-2 launch were compared with predicted levels obtained using the PACES computer program. The comparisons were performed over the frequency range 12.5 Hz to 1000 Hz, since the test data at higher frequencies are contaminated by instrumentation background noise. In general the PACES computer program tends to overpredict the space average sound levels in the payload bay, although the magnitude of the discrepancy is usually small. Furthermore the discrepancy depends to some extent on the manner in which the payload is modeled analytically, and the method used to determine the "measured' space average sound pressure levels. Thus the difference between predicted and measured sound levels, averaged over the 20 one third octave bands from 12.5 Hz to 1000 Hz, varies from 1 dB to 3.5 dB.
Measured Noise from Small Unmanned Aerial Vehicles
NASA Technical Reports Server (NTRS)
Cabell, Randolph; McSwain, Robert; Grosveld, Ferdinand
2016-01-01
Proposed uses of small unmanned aerial vehicles (UAVs), including home package delivery, have the potential to expose large portions of communities to a new noise source. This paper discusses results of flyover noise measurements of four small UAVs, including an internal combustion-powered model airplane and three battery-powered multicopters. Basic noise characteristics of these vehicles are discussed, including spectral properties and sound level metrics such as sound pressure level, effective perceived noise level, and sound exposure level. The size and aerodynamic characteristics of the multicopters in particular make their flight path susceptible to atmospheric disturbances such as wind gusts. These gusts, coupled with a flight control system that varies rotor speed to maintain vehicle stability, create an unsteady acoustic signature. The spectral variations resulting from this unsteadiness are explored, in both hover and flyover conditions for the multicopters. The time varying noise, which differs from the relatively steady noise generated by large transport aircraft, may complicate the prediction of human annoyance using conventional sound level metrics.
Natural and anthropogenic events influence the soundscapes of four bays on Hawaii Island.
Heenehan, Heather L; Van Parijs, Sofie M; Bejder, Lars; Tyne, Julian A; Southall, Brandon L; Southall, Hugh; Johnston, David W
2017-11-15
The soundscapes of four bays along the Kona Coast of Hawaii Island were monitored between January 2011 and March 2013. Equivalent, unweighted sound pressure levels within standard 1/3rd-octave bands (dB re: 1μPa) were calculated for each recording. Sound levels increased at night and were lowest during the daytime when spinner dolphins use the bays to rest. A tsunami provided an opportunity to monitor the soundscape with little anthropogenic component. We detected a decrease in sound levels and variability in one of the busiest bays. During the daytime in the 3.15kHz 1/3rd octave band, we detected 92 loud outliers from vessels, aquaculture, and military mid-frequency active sonar. During one military mid-frequency active sonar event sound levels reached 45.8dB above median ambient noise levels. The differences found in the bays illustrate the importance of understanding soundscapes to effectively manage noise pollution in marine ecosystems. Copyright © 2017 Elsevier Ltd. All rights reserved.
Development and modification of a Gaussian and non-Gaussian noise exposure system
NASA Astrophysics Data System (ADS)
Schlag, Adam W.
Millions of people across the world currently have noise induced hearing loss, and many are working in conditions with both continuous Gaussian and non-Gaussian noises that could affect their hearing. It was hypothesized that the energy of the noise was the cause of the hearing loss and did not depend on temporal pattern of a noise. This was referred to as the equal energy hypothesis. This hypothesis has been shown to have limitations though. This means that there is a difference in the types of noise a person receives to induce hearing loss and it is necessary to build a system that can easily mimic various conditions to conduct research. This study builds a system that can produce both non-Gaussian impulse/impact noises and continuous Gaussian noise. It was found that the peak sound pressure level of the system could reach well above the needed 120 dB level to represent acoustic trauma and could replicate well above the 85 dB A-weighted sound pressure level to produce conditions of gradual developing hearing loss. The system reached a maximum of 150 dB sound peak pressure level and a maximum of 133 dB A-weighted sound pressure level. Various parameters could easily be adjusted to control the sound, such as the high and low cutoff frequency to center the sound at 4 kHz. The system build can easily be adjusted to create numerous sound conditions and will hopefully be modified and improved in hopes of eventually being used for animal studies to lead to the creation of a method to treat or prevent noise induced hearing loss.
Wensveen, Paul J; von Benda-Beckmann, Alexander M; Ainslie, Michael A; Lam, Frans-Peter A; Kvadsheim, Petter H; Tyack, Peter L; Miller, Patrick J O
2015-05-01
The behaviour of a marine mammal near a noise source can modulate the sound exposure it receives. We demonstrate that two long-finned pilot whales both surfaced in synchrony with consecutive arrivals of multiple sonar pulses. We then assess the effect of surfacing and other behavioural response strategies on the received cumulative sound exposure levels and maximum sound pressure levels (SPLs) by modelling realistic spatiotemporal interactions of a pilot whale with an approaching source. Under the propagation conditions of our model, some response strategies observed in the wild were effective in reducing received levels (e.g. movement perpendicular to the source's line of approach), but others were not (e.g. switching from deep to shallow diving; synchronous surfacing after maximum SPLs). Our study exemplifies how simulations of source-whale interactions guided by detailed observational data can improve our understanding about motivations behind behaviour responses observed in the wild (e.g., reducing sound exposure, prey movement). Copyright © 2015 Elsevier Ltd. All rights reserved.
Sound exposure during outdoor music festivals.
Tronstad, Tron V; Gelderblom, Femke B
2016-01-01
Most countries have guidelines to regulate sound exposure at concerts and music festivals. These guidelines limit the allowed sound pressure levels and the concert/festival's duration. In Norway, where there is such a guideline, it is up to the local authorities to impose the regulations. The need to prevent hearing-loss among festival participants is self-explanatory, but knowledge of the actual dose received by visitors is extremely scarce. This study looks at two Norwegian music festivals where only one was regulated by the Norwegian guideline for concert and music festivals. At each festival the sound exposure of four participants was monitored with noise dose meters. This study compared the exposures experienced at the two festivals, and tested them against the Norwegian guideline and the World Health Organization's recommendations. Sound levels during the concerts were higher at the festival not regulated by any guideline, and levels there exceeded both the national and the Worlds Health Organization's recommendations. The results also show that front-of-house measurements reliably predict participant exposure.
Sound Exposure During Outdoor Music Festivals
Tronstad, Tron V.; Gelderblom, Femke B.
2016-01-01
Most countries have guidelines to regulate sound exposure at concerts and music festivals. These guidelines limit the allowed sound pressure levels and the concert/festival's duration. In Norway, where there is such a guideline, it is up to the local authorities to impose the regulations. The need to prevent hearing-loss among festival participants is self-explanatory, but knowledge of the actual dose received by visitors is extremely scarce. This study looks at two Norwegian music festivals where only one was regulated by the Norwegian guideline for concert and music festivals. At each festival the sound exposure of four participants was monitored with noise dose meters. This study compared the exposures experienced at the two festivals, and tested them against the Norwegian guideline and the World Health Organization's recommendations. Sound levels during the concerts were higher at the festival not regulated by any guideline, and levels there exceeded both the national and the Worlds Health Organization's recommendations. The results also show that front-of-house measurements reliably predict participant exposure. PMID:27569410
NASA Technical Reports Server (NTRS)
Powell, C. A.; Mccurdy, D. A.
1978-01-01
Fifty-two airplane noise recordings, made at several locations around Dulles International Airport, were analyzed to compare the low-frequency noise levels of the Concorde supersonic transport with those of other commercial jet airplanes. Comparisons of the relative low-frequency noise levels which were produced at close and distant locations for departures and arrivals were made for three noise measures: the sound pressure level in the 1/3 octave band centered at 20 Hz, the total sound pressure level in the 1/3 octave bands with center frequencies less than or equal to 125 Hz, and the total sound pressure level in the 1/3 octave bands with center frequencies less than or equal to 500 Hz. Although the absolute noise levels for Concorde were found, in general, to be higher than those for the other airplane types, the level of low-frequency noise of the Concorde relative to the perceived noise level (PNL), effective perceived noise level (EPNL), and overall sound pressure level (OASPL) was within the range established by the other airplane types, except for the arrival operations of four-engine, narrow-body airplanes. The measure OASPL was found to be a significantly better predictor of low-frequency noise level than PNL or EPNL.
Four odontocete species change hearing levels when warned of impending loud sound.
Nachtigall, Paul E; Supin, Alexander Ya; Pacini, Aude F; Kastelein, Ronald A
2018-03-01
Hearing sensitivity change was investigated when a warning sound preceded a loud sound in the false killer whale (Pseudorca crassidens), the bottlenose dolphin (Tursiops truncatus), the beluga whale (Delphinaperus leucas) and the harbor porpoise (Phocoena phocoena). Hearing sensitivity was measured using pip-train test stimuli and auditory evoked potential recording. When the test/warning stimuli preceded a loud sound, hearing thresholds before the loud sound increased relative to the baseline by 13 to 17 dB. Experiments with multiple frequencies of exposure and shift provided evidence of different amounts of hearing change depending on frequency, indicating that the hearing sensation level changes were not likely due to a simple stapedial reflex. © 2017 International Society of Zoological Sciences, Institute of Zoology/Chinese Academy of Sciences and John Wiley & Sons Australia, Ltd.
Sterilizing effects of high-intensity airborne sonic and ultrasonic waves.
Pisano, M A; Boucher, M G; Alcamo, I E
1966-09-01
The lethal effects of high-intensity airborne sonic (9.9 kc/sec) and ultrasonic waves (30.4 kc/sec) on spores of Bacillus subtilis var. niger ATCC 9372 were determined. The spores, which were deposited on filter-paper strips, were exposed to sound waves for periods varying from 1 to 8 hr, at a temperature of 40 C and a relative humidity of 40%. Significant reductions in the viable counts of spores exposed to airborne sonic or ultrasonic irradiations were obtained. The antibacterial activity of airborne sound waves varied with the sound intensity level, the period of irradiation, and the distance of the sample from the sound source. At similar intensity levels, the amplitude of motion of the sound waves appeared to be a factor in acoustic sterilization.
Estimating occupant satisfaction of HVAC system noise using quality assessment index.
Forouharmajd, Farhad; Nassiri, Parvin; Monazzam, Mohammad R; Yazdchi, Mohammadreza
2012-01-01
Noise may be defined as any unwanted sound. Sound becomes noise when it is too loud, unexpected, uncontrolled, happens at the wrong time, contains unwanted pure tones or unpleasant. In addition to being annoying, loud noise can cause hearing loss, and, depending on other factors, can affect stress level, sleep patterns and heart rate. The primary object for determining subjective estimations of loudness is to present sounds to a sample of listeners under controlled conditions. In heating, ventilation and air conditioning (HVAC) systems only the ventilation fan industry (e.g., bathroom exhaust and sidewall propeller fans) uses loudness ratings. In order to find satisfaction, percent of exposure to noise is the valuable issue for the personnel who are working in these areas. The room criterion (RC) method has been defined by ANSI standard S12.2, which is based on measured levels of in HVAC systems noise in spaces and is used primarily as a diagnostic tool. The RC method consists of a family of criteria curves and a rating procedure. RC measures background noise in the building over the frequency range of 16-4000 Hz. This rating system requires determination of the mid-frequency average level and determining the perceived balance between high-frequency (HF) sound and low-frequency (LF) sound. The arithmetic average of the sound levels in the 500, 1000 and 2000 Hz octave bands is 44.6 dB; therefore, the RC 45 curve is selected as the reference for spectrum quality evaluation. The spectral deviation factors in the LF, medium-frequency sound and HF regions are 2.9, 7.5 and -2.3, respectively, giving a Quality Assessment Index (QAI) of 9.8. This concludes the QAI is useful in estimating an occupant's probable reaction when the system design does not produce optimum sound quality. Thus, a QAI between 5 and 10 dB represents a marginal situation in which acceptance by an occupant is questionable. However, when sound pressure levels in the 16 or 31.5 Hz octave bands exceed 65 dB, vibration in lightweight office construction is possible.
Evaluation of community response to wind turbine-related noise in western New York state.
Magari, Shannon R; Smith, Clinton E; Schiff, Martin; Rohr, Annette C
2014-01-01
As the boundaries of harvesting wind energy expand to meet the ever-increasing societal energy demands, the number and size of wind turbines being constructed rises. As part of a larger project to monitor sound in an operating wind park in western New York State, a cross-sectional survey was conducted among individuals living in and around the wind park to characterize the perception, level of annoyance, and self-reported health effects of residents. We conducted the study in a 126 MW wind park consisting of 84 turbines spanning approximately 19 square miles of farmland. Short-term outdoor and indoor sound level measurements were also performed at each dwelling in which a questionnaire was administered. To our knowledge, this study is the first to collect sound measurements at individual residences. There was no apparent exposure-response relationship between an individual's level of annoyance and the short duration sound measurements collected at the time of the survey. There was a correlation between an individual's concern regarding health effects and the prevalence of sleep disturbance and stress among the study population. The siting process is unique to each community with varying degrees of success. Additional sound level measurements inside and outside homes in larger cohorts in concert with detailed questionnaires would be useful in verifying those exposure-response relationships found in studies using calculated sound level data. Additional research should include a detailed investigation of sleep patterns and possible disturbance in those living in and near operating wind turbine projects.
Lahav, Amir
2015-01-01
Recent research raises concerns about the adverse effects of noise exposure on the developing preterm infant. However, current guidelines for NICU noise remain focused on loudness levels, leaving the problem of exposure to potentially harmful sound frequencies largely overlooked. This study examined the frequency spectra present in a level-II NICU. Noise measurements were taken in two level-II open-bay nurseries. Measurements were taken over 5 days for a period of 24 h each. Spectral analysis was focused on comparing sound frequencies in the range of human speech during daytime (7 AM-7 PM) vs. night-time (7 PM-7 AM). On average, daytime noise levels (Leq = 60.05 dBA) were higher than night-time (Leq = 58.67 dBA). Spectral analysis of frequency bands (>50 dB) revealed that infants were exposed to frequencies <500 Hz 100% of the time and to frequencies >500 Hz 57% of the time. During daytime, infants were exposed to nearly 20% more sounds within the speech frequency range compared with night-time (p = 0.018). Measuring the frequency spectra of NICU sounds is necessary to attain a thorough understanding of both the noise levels and the type of sounds that preterm infants are exposed to throughout their hospital stay. The risk of high-frequency noise exposure in the preterm population is still unclear and warrants further investigation. © 2014 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.
The Encoding of Sound Source Elevation in the Human Auditory Cortex.
Trapeau, Régis; Schönwiesner, Marc
2018-03-28
Spatial hearing is a crucial capacity of the auditory system. While the encoding of horizontal sound direction has been extensively studied, very little is known about the representation of vertical sound direction in the auditory cortex. Using high-resolution fMRI, we measured voxelwise sound elevation tuning curves in human auditory cortex and show that sound elevation is represented by broad tuning functions preferring lower elevations as well as secondary narrow tuning functions preferring individual elevation directions. We changed the ear shape of participants (male and female) with silicone molds for several days. This manipulation reduced or abolished the ability to discriminate sound elevation and flattened cortical tuning curves. Tuning curves recovered their original shape as participants adapted to the modified ears and regained elevation perception over time. These findings suggest that the elevation tuning observed in low-level auditory cortex did not arise from the physical features of the stimuli but is contingent on experience with spectral cues and covaries with the change in perception. One explanation for this observation may be that the tuning in low-level auditory cortex underlies the subjective perception of sound elevation. SIGNIFICANCE STATEMENT This study addresses two fundamental questions about the brain representation of sensory stimuli: how the vertical spatial axis of auditory space is represented in the auditory cortex and whether low-level sensory cortex represents physical stimulus features or subjective perceptual attributes. Using high-resolution fMRI, we show that vertical sound direction is represented by broad tuning functions preferring lower elevations as well as secondary narrow tuning functions preferring individual elevation directions. In addition, we demonstrate that the shape of these tuning functions is contingent on experience with spectral cues and covaries with the change in perception, which may indicate that the tuning functions in low-level auditory cortex underlie the perceived elevation of a sound source. Copyright © 2018 the authors 0270-6474/18/383252-13$15.00/0.
Sound wave energy emitted by water drop during the splash on the soil surface
NASA Astrophysics Data System (ADS)
Bieganowski, Andrzej; Ryżak, Magdalena; Korbiel, Tomasz
2017-04-01
A drop of rain falling on the surface of bare soil not only moisturizes but also can cause splash or compaction, depending on the energy of incident drops and the condition of the surface on which it falls. The splash phenomenon can be characterized by the weight of detached soil material (using splash cups) as well as the number and trajectory of splashed particles (using high-speed cameras). The study presents a new aspect of the analysis of the splash phenomenon by measurement of the sound pressure level and the sound energy of the wave that propagates in the air. The measurements were carried out in an anechoic chamber. Three soils (Endogleyic Umbrisol, Fluvic Endogleyic Cambisol, and Haplic Chernozem) with four initial moisture levels (pressure heads: 0.1 kPa, 1 kPa, 3.16 kPa, and 16 kPa) were tested. Drops of 4.2 mm diameter were falling from a height of 1.5m. The sound pressure level was recorded after 10 consecutive water drop impacts using a special set of microphones. In all measuring conditions with 1m distance, the sound pressure level ranged from 27 to 42dB. The impact of water drops on the ground created sound pulses, which were recalculated to the energy emitted in the form of sound waves. For all soil samples, the sound wave energy was within the range of 0.14 μJ to 5.26 μJ, which corresponds to 0.03-1.07% of the energy of the incident drops (Ryżak et al., 2016). This work was partly financed from the National Science Centre, Poland; project no. 2014/14/E/ST10/00851. References Ryżak M., Bieganowski A., Korbiel T.: Sound wave Energy resulting from the impact of water drops on the soil surface. PLoS One 11(7):e0158472. doi:10.1371/journal.pone.0158472, 2016
Behavioural Response Thresholds in New Zealand Crab Megalopae to Ambient Underwater Sound
Stanley, Jenni A.; Radford, Craig A.; Jeffs, Andrew G.
2011-01-01
A small number of studies have demonstrated that settlement stage decapod crustaceans are able to detect and exhibit swimming, settlement and metamorphosis responses to ambient underwater sound emanating from coastal reefs. However, the intensity of the acoustic cue required to initiate the settlement and metamorphosis response, and therefore the potential range over which this acoustic cue may operate, is not known. The current study determined the behavioural response thresholds of four species of New Zealand brachyuran crab megalopae by exposing them to different intensity levels of broadcast reef sound recorded from their preferred settlement habitat and from an unfavourable settlement habitat. Megalopae of the rocky-reef crab, Leptograpsus variegatus, exhibited the lowest behavioural response threshold (highest sensitivity), with a significant reduction in time to metamorphosis (TTM) when exposed to underwater reef sound with an intensity of 90 dB re 1 µPa and greater (100, 126 and 135 dB re 1 µPa). Megalopae of the mud crab, Austrohelice crassa, which settle in soft sediment habitats, exhibited no response to any of the underwater reef sound levels. All reef associated species exposed to sound levels from an unfavourable settlement habitat showed no significant change in TTM, even at intensities that were similar to their preferred reef sound for which reductions in TTM were observed. These results indicated that megalopae were able to discern and respond selectively to habitat-specific acoustic cues. The settlement and metamorphosis behavioural response thresholds to levels of underwater reef sound determined in the current study of four species of crabs, enables preliminary estimation of the spatial range at which an acoustic settlement cue may be operating, from 5 m to 40 km depending on the species. Overall, these results indicate that underwater sound is likely to play a major role in influencing the spatial patterns of settlement of coastal crab species. PMID:22163314
Lee, Kyoung-Ryul; Jang, Sung Hwan; Jung, Inhwa
2018-08-10
We investigated the acoustic performance of electrostatic sound-generating devices consisting of bi-layer graphene on polyimide film. The total sound pressure level (SPL) of the sound generated from the devices was measured as a function of source frequency by sweeping, and frequency spectra were measured at 1/3 octave band frequencies. The relationship between various operation conditions and total SPL was determined. In addition, the effects of changing voltage level, adding a DC offset, and using two pairs of electrodes were evaluated. It should be noted that two pairs of electrode operations improved sound generation by about 10 dB over all frequency ranges compared with conventional operation. As for the sound-generating capability, total SPL was 70 dBA at 4 kHz when an AC voltage of 100 V pp was applied with a DC offset of 100 V. Acoustic characteristics differed from other types of graphene-based sound generators, such as graphene thermoacoustic devices and graphene polyvinylidene fluoride devices. The effects of diameter and distance between electrodes were also studied, and we found that diameter greatly influenced the frequency response. We anticipate that the design information provided in this paper, in addition to describing key parameters of electrostatic sound-generating devices, will facilitate the commercial development of electrostatic sound-generating systems.
Bevelhimer, Mark S.; Deng, Z. Daniel; Scherelis, Constantin C.
2016-01-06
Underwaternoise associated with the installation and operation of hydrokinetic turbines in rivers and tidal zones presents a potential environmental concern for fish and marine mammals. Comparing the spectral quality of sounds emitted by hydrokinetic turbines to natural and other anthropogenic sound sources is an initial step at understanding potential environmental impacts. Underwater recordings were obtained from passing vessels and natural underwater sound sources in static and flowing waters. Static water measurements were taken in a lake with minimal background noise. Flowing water measurements were taken at a previously proposed deployment site for hydrokinetic turbines on the Mississippi River, where soundsmore » created by flowing water are part of all measurements, both natural ambient and anthropogenic sources. Vessel sizes ranged from a small fishing boat with 60 hp outboard motor to an 18-unit barge train being pushed upstream by tugboat. As expected, large vessels with large engines created the highest sound levels, which were, on average, 40 dB greater than the sound created by an operating hydrokinetic turbine. As a result, a comparison of sound levels from the same sources at different distances using both spherical and cylindrical sound attenuation functions suggests that spherical model results more closely approximate observed sound attenuation.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bevelhimer, Mark S.; Deng, Z. Daniel; Scherelis, Constantin
2016-01-01
Underwater noise associated with the installation and operation of hydrokinetic turbines in rivers and tidal zones presents a potential environmental concern for fish and marine mammals. Comparing the spectral quality of sounds emitted by hydrokinetic turbines to natural and other anthropogenic sound sources is an initial step at understanding potential environmental impacts. Underwater recordings were obtained from passing vessels of different sizes and other underwater sound sources in both static and flowing waters. Static water measurements were taken in a lake with minimal background noise. Flowing water measurements were taken at a previously proposed deployment site for hydrokinetic turbines onmore » the Mississippi River, where the sound of flowing water is included in background measurements. The size of vessels measured ranged from a small fishing boat with a 60 HP outboard motor to an 18-unit barge train being pushed upstream by tugboat. As expected, large vessels with large engines created the highest sound levels, and when compared to the sound created by an operating HK turbine were many times greater. A comparison of sound levels from the same sources at different distances using both spherical and cylindrical sound attenuation functions suggests that spherical model results more closely approximate observed values.« less
Limiting hazardous noise exposure from noisy toys: simple, sticky solutions.
Weinreich, Heather M; Jabbour, Noel; Levine, Samuel; Yueh, Bevan
2013-09-01
To assess noise levels of toys from the Sight & Hearing Association (SHA) 2010 Noisy Toys List and evaluate the change in noise of these toys after covering the speakers with tape or glue. One Group Pretest-Posttest Design. SHA 2010 Toys List (n = 18) toys were tested at distances of 0 and 25 cm from sound source in a soundproof booth using a digital sound-level meter. The dBA level of sound produced by toy was obtained. Toys with speakers (n = 16) were tested before and after altering speakers with plastic packing tape or nontoxic glue. Mean noise level for non-taped toys at 0 and 25 cm was 107.6 dBA (SD ± 8.5) and 82.5 dBA (SD ± 8.8), respectively. With tape, there was a statistically significant decrease in noise level at 0 and 25 cm: 84.2 dBA and 68.2 dBA (P <0.001). With glue, there was a statistically significant decrease in noise level at 0 cm and 25 cm: 79.7 dBA and 66.4 dBA (P <0.001). Both tape and glue significantly decreased the noise level produced by the toys. However, there was no significant difference between tape or glue. Overall, altering the toy can significantly decrease the sound a child may experience when playing with toys. However, some toys, even after altering, still produce sound levels that may be considered dangerous. Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.
The softest sound levels of the human voice in normal subjects.
Šrámková, Hana; Granqvist, Svante; Herbst, Christian T; Švec, Jan G
2015-01-01
Accurate measurement of the softest sound levels of phonation presents technical and methodological challenges. This study aimed at (1) reliably obtaining normative data on sustained softest sound levels for the vowel [a:] at comfortable pitch; (2) comparing the results for different frequency and time weighting methods; and (3) refining the Union of European Phoniatricians' recommendation on allowed background noise levels for scientific and equipment manufacturers' purposes. Eighty healthy untrained participants (40 females, 40 males) were investigated in quiet rooms using a head-mounted microphone and a sound level meter at 30 cm distance. The one-second-equivalent sound levels were more stable and more representative for evaluating the softest sustained phonations than the fast-time-weighted levels. At 30 cm, these levels were in the range of 48-61 dB(C)/41-53 dB(A) for females and 49 - 64 dB(C)/35-53 dB(A) for males (5% to 95% quantile range). These ranges may serve as reference data in evaluating vocal normality. In order to reach a signal-to-noise ratio of at least 10 dB for more than 95% of the normal population, the background noise should be below 25 dB(A) and 38 dB(C), respectively, for the softest phonation measurements at 30 cm distance. For the A-weighting, this is 15 dB lower than the previously recommended value.
Stapes displacement and intracochlear pressure in response to very high level, low frequency sounds.
Greene, Nathaniel T; Jenkins, Herman A; Tollin, Daniel J; Easter, James R
2017-05-01
The stapes is held in the oval window by the stapedial annular ligament (SAL), which restricts total peak-to-peak displacement of the stapes. Previous studies have suggested that for moderate (<130 dB SPL) sound levels intracochlear pressure (P IC ), measured at the base of the cochlea far from the basilar membrane, increases directly proportionally with stapes displacement (D Stap ), thus a current model of impulse noise exposure (the Auditory Hazard Assessment Algorithm for Humans, or AHAAH) predicts that peak P IC will vary linearly with D Stap up to some saturation point. However, no direct tests of D Stap , or of the relationship with P IC during such motion, have been performed during acoustic stimulation of the human ear. In order to examine the relationship between D Stap and P IC to very high level sounds, measurements of D Stap and P IC were made in cadaveric human temporal bones. Specimens were prepared by mastoidectomy and extended facial recess to expose the ossicular chain. Measurements of P IC were made in scala vestibuli (P SV ) and scala tympani (P ST ), along with the SPL in the external auditory canal (P EAC ), concurrently with laser Doppler vibrometry (LDV) measurements of stapes velocity (V Stap ). Stimuli were moderate (∼100 dB SPL) to very high level (up to ∼170 dB SPL), low frequency tones (20-2560 Hz). Both D Stap and P SV increased proportionally with sound pressure level in the ear canal up to approximately ∼150 dB SPL, above which both D Stap and P SV showed a distinct deviation from proportionality with P EAC . Both D Stap and P SV approached saturation: D Stap at a value exceeding 150 μm, which is substantially higher than has been reported for small mammals, while P SV showed substantial frequency dependence in the saturation point. The relationship between P SV and D Stap remained constant, and cochlear input impedance did not vary across the levels tested, consistent with prior measurements at lower sound levels. These results suggest that P SV sound pressure holds constant relationship with D Stap , described by the cochlear input impedance, at these, but perhaps not higher, stimulation levels. Additionally, these results indicate that the AHAAH model, which was developed using results from small animals, underestimates the sound pressure levels in the cochlea in response to high level sound stimulation, and must be revised. Copyright © 2017 Elsevier B.V. All rights reserved.
Tutorial and Guidelines on Measurement of Sound Pressure Level in Voice and Speech
ERIC Educational Resources Information Center
Švec, Jan G.; Granqvist, Svante
2018-01-01
Purpose: Sound pressure level (SPL) measurement of voice and speech is often considered a trivial matter, but the measured levels are often reported incorrectly or incompletely, making them difficult to compare among various studies. This article aims at explaining the fundamental principles behind these measurements and providing guidelines to…
Noise in early childhood education institutions.
Bitar, Mariangela Lopes; Calaço, Luiz Ferreira; Simões-Zenari, Marcia
2018-01-01
High sound pressure levels have been observed in schools, and its interference in the health of children and teachers it was taken to analyze these levels in childhood education centers serving children aged zero to six years, investigate the staff's perceptions concerning noise exposure and identify the auditory conditions of these workers and the occurrence of diseases. The study was conducted in ten institutions employing 320 workers. Sound pressure levels were measured according to the technical norms; employees completed a questionnaire on the perception of noise and underwent auditory evaluation. There was high sound pressure level and differences between institutions, situations and places. Most employees are considered exposed to noise with attention and concentration difficulties, anxiety and headache. About 30% of employees had bilateral sensorineural hearing loss in specific frequency. The sound pressure levels found can affect children's learning and the health of all. The employees also perceived elevated levels of noise and indicated some possible negative aspects in their work routine. Actions to improve the acoustic comfort in these institutions will be discussed with the management teams.
On the Possible Detection of Lightning Storms by Elephants
Kelley, Michael C.; Garstang, Michael
2013-01-01
Simple Summary We use data similar to that taken by the International Monitoring System for the detection of nuclear explosions, to determine whether elephants might be capable of detecting and locating the source of sounds generated by thunderstorms. Knowledge that elephants might be capable of responding to such storms, particularly at the end of the dry season when migrations are initiated, is of considerable interest to management and conservation. Abstract Theoretical calculations suggest that sounds produced by thunderstorms and detected by a system similar to the International Monitoring System (IMS) for the detection of nuclear explosions at distances ≥100 km, are at sound pressure levels equal to or greater than 6 × 10−3 Pa. Such sound pressure levels are well within the range of elephant hearing. Frequencies carrying these sounds might allow for interaural time delays such that adult elephants could not only hear but could also locate the source of these sounds. Determining whether it is possible for elephants to hear and locate thunderstorms contributes to the question of whether elephant movements are triggered or influenced by these abiotic sounds. PMID:26487406
Recovery of Neonatal Head Turning to Decreased Sound Pressure Level.
ERIC Educational Resources Information Center
Tarquinio, Nancy; And Others
1990-01-01
Investigated newborns' responses to decreased sound pressure level (SPL) by means of a localized head turning habituation procedure. Findings, which demonstrated recovery of neonatal head turning to decreased SPL, were inconsistent with the selective receptor adaptation model. (RH)
Determination of a sound level for railroad horn regulatory compliance.
DOT National Transportation Integrated Search
2002-10-31
The Federal Railroad Administration (FRA) has undertaken a rulemaking process to address the use of locomotive horns at public highway-railroad grade crossings. This rule includes a provision to regulate the sound level output of railroad horns. This...
Another ``new'' metric for outdoor amphitheater criteria
NASA Astrophysics Data System (ADS)
Berens, Robert S.
2005-09-01
Since the late 1960s, when amplified musical performances began being held there, Atlanta's open-air Chastain Park Amphitheater has been the source of enormous friction between the City, the venue's owner, and the wealthy, politically-connected residential community abutting the Park. To identify the characteristics of concert event sound to which neighbors are particularly sensitive, sound levels were monitored during 17 concerts, ranging from quiet jazz and classical performances to rock-and-roll and hip-hop. Community sound levels were monitored at 25 locations, including nine where measurements were made simultaneously inside and outside homes. The study team confirmed that low-frequency sound was the one feature of concert-related sound that community residents identified as most problematic, but that only a relatively small proportion of the Chastain concerts resulted in any significant community annoyance. After assessing the spectral characteristics of the most troublesome concerts, a new compliance metric has been proposed to address low-frequency annoyance issues: a two-tiered exceedence threshold, based on 1-minute LEQ levels in the 63 Hz octave band measured at the rear of the amphitheater, with a concert-event ``exceedence'' defined to be either a 1-minute LEQ(63 Hz) level greater than 95 dB or more than ten 1-minute LEQ(63 Hz) levels greater than 90 dB.
Evaluation of Variable-Depth Liner Configurations for Increased Broadband Noise Reduction
NASA Technical Reports Server (NTRS)
Jones, M. G.; Watson, W. R.; Nark, D. M.; Howerton, B. M.
2015-01-01
This paper explores the effects of variable-depth geometry on the amount of noise reduction that can be achieved with acoustic liners. Results for two variable-depth liners tested in the NASA Langley Grazing Flow Impedance Tube demonstrate significant broadband noise reduction. An impedance prediction model is combined with two propagation codes to predict corresponding sound pressure level profiles over the length of the Grazing Flow Impedance Tube. The comparison of measured and predicted sound pressure level profiles is sufficiently favorable to support use of these tools for investigation of a number of proposed variable-depth liner configurations. Predicted sound pressure level profiles for these proposed configurations reveal a number of interesting features. Liner orientation clearly affects the sound pressure level profile over the length of the liner, but the effect on the total attenuation is less pronounced. The axial extent of attenuation at an individual frequency continues well beyond the location where the liner depth is optimally tuned to the quarter-wavelength of that frequency. The sound pressure level profile is significantly affected by the way in which variable-depth segments are distributed over the length of the liner. Given the broadband noise reduction capability for these liner configurations, further development of impedance prediction models and propagation codes specifically tuned for this application is warranted.
Variability of road traffic noise recorded by stationary monitoring stations
NASA Astrophysics Data System (ADS)
Bąkowski, Andrzej; Radziszewski, Leszek
2017-11-01
The paper presents the analysis results of equivalent sound level recorded by two road traffic noise monitoring stations. The stations were located in Kielce (an example of a medium-size town in Poland) at the roads out of the town in the direction of Kraków and Warszawa. The measurements were carried out through stationary stations monitoring the noise and traffic of motor vehicles. The RMS values based on A-weighted sound level were recorded every 1 s in the buffer and the results were registered every 1 min over the period of investigations. The registered data were the basis for calculating the equivalent sound level for three time intervals: from 6:00 to 18:00, from 18:00 to 22:00 and from 22:00 to 6:00. Analysis included the values of the equivalent sound level recorded for different days of the week split into 24h periods, nights, days and evenings. The data analysed included recordings from 2013. The coefficient of variation and positional variation were proposed for performing comparative analysis of the obtained data scattering. The investigations indicated that the recorded data varied depending on the traffic routes. The differences concerned the values of coefficients of variation of the equivalent sound levels.
Lauer, Amanda M.; May, Bradford J.; Hao, Ziwei Judy; Watson, Julie
2009-01-01
Noise in animal housing facilities is an environmental variable that can affect hearing, behavior and physiology in mice. The authors measured sound levels in two rodent housing rooms (room 1 and room 2) during several periods of 24 h. Room 1, which was subject to heavy personnel traffic, contained ventilated racks and static cages that housed large numbers of mice. Room 2 was accessed by only a few staff members and contained only static cages that housed fewer mice. In both rooms, background sound levels were about 80 dB, and transient noises caused sound levels to temporarily rise 30–40 dB above the baseline level; such peaks occurred frequently during work hours (8:30 AM to 4:30 PM) and infrequently during non-work hours. Noise peaks during work hours in room 1 occurred about two times as often as in room 2 (P = 0.01). Use of changing stations located in the rooms caused background noise to increase by about 10 dB. Loud noise and noise variability were attributed mainly to personnel activity. Attempts to reduce noise should concentrate on controlling sounds produced by in-room activities and experimenter traffic; this may reduce the variability of research outcomes and improve animal welfare. PMID:19384312
Miller, Patrick J O
2006-05-01
Signal source intensity and detection range, which integrates source intensity with propagation loss, background noise and receiver hearing abilities, are important characteristics of communication signals. Apparent source levels were calculated for 819 pulsed calls and 24 whistles produced by free-ranging resident killer whales by triangulating the angles-of-arrival of sounds on two beamforming arrays towed in series. Levels in the 1-20 kHz band ranged from 131 to 168 dB re 1 microPa at 1 m, with differences in the means of different sound classes (whistles: 140.2+/-4.1 dB; variable calls: 146.6+/-6.6 dB; stereotyped calls: 152.6+/-5.9 dB), and among stereotyped call types. Repertoire diversity carried through to estimates of active space, with "long-range" stereotyped calls all containing overlapping, independently-modulated high-frequency components (mean estimated active space of 10-16 km in sea state zero) and "short-range" sounds (5-9 km) included all stereotyped calls without a high-frequency component, whistles, and variable calls. Short-range sounds are reported to be more common during social and resting behaviors, while long-range stereotyped calls predominate in dispersed travel and foraging behaviors. These results suggest that variability in sound pressure levels may reflect diverse social and ecological functions of the acoustic repertoire of killer whales.
Sounds and source levels from bowhead whales off Pt. Barrow, Alaska.
Cummings, W C; Holliday, D V
1987-09-01
Sounds were recorded from bowhead whales migrating past Pt. Barrow, AK, to the Canadian Beaufort Sea. They mainly consisted of various low-frequency (25- to 900-Hz) moans and well-defined sound sequences organized into "song" (20-5000 Hz) recorded with our 2.46-km hydrophone array suspended from the ice. Songs were composed of up to 20 repeated phrases (mean, 10) which lasted up to 146 s (mean, 66.3). Several bowhead whales often were within acoustic range of the array at once, but usually only one sang at a time. Vocalizations exhibited diurnal peaks of occurrence (0600-0800, 1600-1800 h). Sounds which were located in the horizontal plane had peak source spectrum levels as follows--44 moans: 129-178 dB re: 1 microPa, 1 m (median, 159); 3 garglelike utterances: 152, 155, and 169 dB; 33 songs: 158-189 dB (median, 177), all presumably from different whales. Based on ambient noise levels, measured total propagation loss, and whale sound source levels, our detection of whale sounds was theoretically noise-limited beyond 2.5 km (moans) and beyond 10.7 km (songs), a model supported by actual localizations. This study showed that over much of the shallow Arctic and sub-Arctic waters, underwater communications of the bowhead whale would be limited to much shorter ranges than for other large whales in lower latitude, deep-water regions.
Calderon, Lindsay E; Carney, Logan D; Kavanagh, Kevin T
2016-01-01
In this study the authors investigate the sound pressure levels produced by crying children and discuss the possible adverse effects that direct exposure may impose on a tending guardian or healthcare professional. Sound intensity levels from various pediatric patients (N = 26) were measured under two segregate conditions, one imitating the exposure of an examining physician and the other resembling that of parental guardians. Interestingly, all of the recorded sound levels fell between 99-120 dB(A) of sound pressure; children presenting the greatest risk for intense cries with potentially harmful sound intensities were between the ages of 9 months and 6 years. The authors found that elevated noise levels produced from crying children can cause acute discomfort and mild pain to those exposed. In addition, there is a theoretical risk that chronic exposure to these intense sound pressures may result in noise-induced hearing loss in a parental guardian or an examining physician. Parents of young children may be more likely to succumb to impulsive reactions in attempting to arrest the crying, which could be a precipitating factor for child abuse, responding to physical stress as much as emotional stress. Social workers and medical personnel should consider suggesting the use of ear plugs by parental guardians of frequently crying children as a modality for the prevention of child abuse.
Spiking Models for Level-Invariant Encoding
Brette, Romain
2012-01-01
Levels of ecological sounds vary over several orders of magnitude, but the firing rate and membrane potential of a neuron are much more limited in range. In binaural neurons of the barn owl, tuning to interaural delays is independent of level differences. Yet a monaural neuron with a fixed threshold should fire earlier in response to louder sounds, which would disrupt the tuning of these neurons. How could spike timing be independent of input level? Here I derive theoretical conditions for a spiking model to be insensitive to input level. The key property is a dynamic change in spike threshold. I then show how level invariance can be physiologically implemented, with specific ionic channel properties. It appears that these ingredients are indeed present in monaural neurons of the sound localization pathway of birds and mammals. PMID:22291634
Development of neural responsivity to vocal sounds in higher level auditory cortex of songbirds
Miller-Sims, Vanessa C.
2014-01-01
Like humans, songbirds learn vocal sounds from “tutors” during a sensitive period of development. Vocal learning in songbirds therefore provides a powerful model system for investigating neural mechanisms by which memories of learned vocal sounds are stored. This study examined whether NCM (caudo-medial nidopallium), a region of higher level auditory cortex in songbirds, serves as a locus where a neural memory of tutor sounds is acquired during early stages of vocal learning. NCM neurons respond well to complex auditory stimuli, and evoked activity in many NCM neurons habituates such that the response to a stimulus that is heard repeatedly decreases to approximately one-half its original level (stimulus-specific adaptation). The rate of neural habituation serves as an index of familiarity, being low for familiar sounds, but high for novel sounds. We found that response strength across different song stimuli was higher in NCM neurons of adult zebra finches than in juveniles, and that only adult NCM responded selectively to tutor song. The rate of habituation across both tutor song and novel conspecific songs was lower in adult than in juvenile NCM, indicating higher familiarity and a more persistent response to song stimuli in adults. In juvenile birds that have memorized tutor vocal sounds, neural habituation was higher for tutor song than for a familiar conspecific song. This unexpected result suggests that the response to tutor song in NCM at this age may be subject to top-down influences that maintain the tutor song as a salient stimulus, despite its high level of familiarity. PMID:24694936
Assessment on transient sound radiation of a vibrating steel bridge due to traffic loading
NASA Astrophysics Data System (ADS)
Zhang, He; Xie, Xu; Jiang, Jiqing; Yamashita, Mikio
2015-02-01
Structure-borne noise induced by vehicle-bridge coupling vibration is harmful to human health and living environment. Investigating the sound pressure level and the radiation mechanism of structure-borne noise is of great significance for the assessment of environmental noise pollution and noise control. In this paper, the transient noise induced by vehicle-bridge coupling vibration is investigated by employing the hybrid finite element method (FEM) and boundary element method (BEM). The effect of local vibration of the bridge deck is taken into account and the sound responses of the structure-borne noise in time domain is obtained. The precision of the proposed method is validated by comparing numerical results to the on-site measurements of a steel girder-plate bridge in service. It implies that the sound pressure level and its distribution in both time and frequency domains may be predicted by the hybrid approach of FEM-BEM with satisfactory accuracy. Numerical results indicate that the vibrating steel bridge radiates high-level noise because of its extreme flexibility and large surface area for sound radiation. The impact effects of the vehicle on the sound pressure when leaving the bridge are observed. The shape of the contour lines in the area around the bridge deck could be explained by the mode shapes of the bridge. The moving speed of the vehicle only affects the sound pressure components with frequencies lower than 10 Hz.
A numerical study of fundamental shock noise mechanisms. Ph.D. Thesis - Cornell Univ.
NASA Technical Reports Server (NTRS)
Meadows, Kristine R.
1995-01-01
The results of this thesis demonstrate that direct numerical simulation can predict sound generation in unsteady aerodynamic flows containing shock waves. Shock waves can be significant sources of sound in high speed jet flows, on helicopter blades, and in supersonic combustion inlets. Direct computation of sound permits the prediction of noise levels in the preliminary design stage and can be used as a tool to focus experimental studies, thereby reducing cost and increasing the probability of a successfully quiet product in less time. This thesis reveals and investigates two mechanisms fundamental to sound generation by shocked flows: shock motion and shock deformation. Shock motion is modeled by the interaction of a sound wave with a shock. During the interaction, the shock wave begins to move and the sound pressure is amplified as the wave passes through the shock. The numerical approach presented in this thesis is validated by the comparison of results obtained in a quasi-one dimensional simulation with linear theory. Analysis of the perturbation energy demonstrated for the first time that acoustic energy is generated by the interaction. Shock deformation is investigated by the numerical simulation of a ring vortex interacting with a shock. This interaction models the passage of turbulent structures through the shock wave. The simulation demonstrates that both acoustic waves and contact surfaces are generated downstream during the interaction. Analysis demonstrates that the acoustic wave spreads cylindrically, that the sound intensity is highly directional, and that the sound pressure level increases significantly with increasing shock strength. The effect of shock strength on sound pressure level is consistent with experimental observations of shock noise, indicating that the interaction of a ring vortex with a shock wave correctly models a dominant mechanism of shock noise generation.
Cheng, Liang; Wang, Shao-Hui; Peng, Kang; Liao, Xiao-Mei
2017-01-01
Most citizen people are exposed daily to environmental noise at moderate levels with a short duration. The aim of the present study was to determine the effects of daily short-term exposure to moderate noise on sound level processing in the auditory midbrain. Sound processing properties of auditory midbrain neurons were recorded in anesthetized mice exposed to moderate noise (80 dB SPL, 2 h/d for 6 weeks) and were compared with those from age-matched controls. Neurons in exposed mice had a higher minimum threshold and maximum response intensity, a longer first spike latency, and a higher slope and narrower dynamic range for rate level function. However, these observed changes were greater in neurons with the best frequency within the noise exposure frequency range compared with those outside the frequency range. These sound processing properties also remained abnormal after a 12-week period of recovery in a quiet laboratory environment after completion of noise exposure. In conclusion, even daily short-term exposure to moderate noise can cause long-term impairment of sound level processing in a frequency-specific manner in auditory midbrain neurons.
Attention modifies sound level detection in young children.
Sussman, Elyse S; Steinschneider, Mitchell
2011-07-01
Have you ever shouted your child's name from the kitchen while they were watching television in the living room to no avail, so you shout their name again, only louder? Yet, still no response. The current study provides evidence that young children process loudness changes differently than pitch changes when they are engaged in another task such as watching a video. Intensity level changes were physiologically detected only when they were behaviorally relevant, but frequency level changes were physiologically detected without task relevance in younger children. This suggests that changes in pitch rather than changes in volume may be more effective in evoking a response when sounds are unexpected. Further, even though behavioral ability may appear to be similar in younger and older children, attention-based physiologic responses differ from automatic physiologic processes in children. Results indicate that 1) the automatic auditory processes leading to more efficient higher-level skills continue to become refined through childhood; and 2) there are different time courses for the maturation of physiological processes encoding the distinct acoustic attributes of sound pitch and sound intensity. The relevance of these findings to sound perception in real-world environments is discussed.
Cheng, Liang; Wang, Shao-Hui; Peng, Kang
2017-01-01
Most citizen people are exposed daily to environmental noise at moderate levels with a short duration. The aim of the present study was to determine the effects of daily short-term exposure to moderate noise on sound level processing in the auditory midbrain. Sound processing properties of auditory midbrain neurons were recorded in anesthetized mice exposed to moderate noise (80 dB SPL, 2 h/d for 6 weeks) and were compared with those from age-matched controls. Neurons in exposed mice had a higher minimum threshold and maximum response intensity, a longer first spike latency, and a higher slope and narrower dynamic range for rate level function. However, these observed changes were greater in neurons with the best frequency within the noise exposure frequency range compared with those outside the frequency range. These sound processing properties also remained abnormal after a 12-week period of recovery in a quiet laboratory environment after completion of noise exposure. In conclusion, even daily short-term exposure to moderate noise can cause long-term impairment of sound level processing in a frequency-specific manner in auditory midbrain neurons. PMID:28589040
NASA Astrophysics Data System (ADS)
Haver, Samara M.; Klinck, Holger; Nieukirk, Sharon L.; Matsumoto, Haru; Dziak, Robert P.; Miksis-Olds, Jennifer L.
2017-04-01
Anthropogenic noise in the ocean has been shown, under certain conditions, to influence the behavior and health of marine mammals. Noise from human activities may interfere with the low-frequency acoustic communication of many Mysticete species, including blue (Balaenoptera musculus) and fin whales (B. physalus). This study analyzed three soundscapes in the Atlantic Ocean, from the Arctic to the Antarctic, to document ambient sound. For 16 months beginning in August 2009, acoustic data (15-100 Hz) were collected in the Fram Strait (79°N, 5.5°E), near Ascension Island (8°S, 14.4°W) and in the Bransfield Strait (62°S, 55.5°W). Results indicate (1) the highest overall sound levels were measured in the equatorial Atlantic, in association with high levels of seismic oil and gas exploration, (2) compared to the tropics, ambient sound levels in polar regions are more seasonally variable, and (3) individual elements beget the seasonal and annual variability of ambient sound levels in high latitudes. Understanding how the variability of natural and man-made contributors to sound may elicit differences in ocean soundscapes is essential to developing strategies to manage and conserve marine ecosystems and animals.
Improvement of the predicted aural detection code ICHIN (I Can Hear It Now)
NASA Technical Reports Server (NTRS)
Mueller, Arnold W.; Smith, Charles D.; Lemasurier, Phillip
1993-01-01
Acoustic tests were conducted to study the far-field sound pressure levels and aural detection ranges associated with a Sikorsky S-76A helicopter in straight and level flight at various advancing blade tip Mach numbers. The flight altitude was nominally 150 meters above ground level. This paper compares the normalized predicted aural detection distances, based on the measured far-field sound pressure levels, to the normalized measured aural detection distances obtained from sound jury response measurements obtained during the same test. Both unmodified and modified versions of the prediction code ICHIN-6 (I Can Hear It Now) were used to produce the results for this study.
Alards-Tomalin, Doug; Walker, Alexander C; Shaw, Joshua D M; Leboe-McGowan, Launa C
2015-09-01
The cross-modal impact of number magnitude (i.e. Arabic digits) on perceived sound loudness was examined. Participants compared a target sound's intensity level against a previously heard reference sound (which they judged as quieter or louder). Paired with each target sound was a task irrelevant Arabic digit that varied in magnitude, being either small (1, 2, 3) or large (7, 8, 9). The degree to which the sound and the digit were synchronized was manipulated, with the digit and sound occurring simultaneously in Experiment 1, and the digit preceding the sound in Experiment 2. Firstly, when target sounds and digits occurred simultaneously, sounds paired with large digits were categorized as loud more frequently than sounds paired with small digits. Secondly, when the events were separated, number magnitude ceased to bias sound intensity judgments. In Experiment 3, the events were still separated, however the participants held the number in short-term memory. In this instance the bias returned. Copyright © 2015 Elsevier B.V. All rights reserved.
40 CFR 201.22 - Measurement instrumentation.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Measurement instrumentation. 201.22 Section 201.22 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) NOISE ABATEMENT... Criteria § 201.22 Measurement instrumentation. (a) A sound level meter or alternate sound level measurement...
40 CFR 201.22 - Measurement instrumentation.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Measurement instrumentation. 201.22 Section 201.22 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) NOISE ABATEMENT... Criteria § 201.22 Measurement instrumentation. (a) A sound level meter or alternate sound level measurement...
40 CFR 201.22 - Measurement instrumentation.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Measurement instrumentation. 201.22 Section 201.22 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) NOISE ABATEMENT... Criteria § 201.22 Measurement instrumentation. (a) A sound level meter or alternate sound level measurement...
Knudson, Inge M; Melcher, Jennifer R
2016-06-01
Increases in the acoustic startle response (ASR) of animals have been reported following experimental manipulations to induce tinnitus, an auditory disorder defined by phantom perception of sound. The increases in ASR have been proposed to signify the development of hyperacusis, a clinical condition defined by intolerance of normally tolerable sound levels. To test this proposal, the present study compared ASR amplitude to measures of sound-level tolerance (SLT) in humans, the only species in which SLT can be directly assessed. Participants had clinically normal/near-normal hearing thresholds, were free of psychotropic medications, and comprised people with tinnitus and without. ASR was measured as eyeblink-related electromyographic activity in response to a noise pulse presented at a range of levels and in two background conditions (noise and quiet). SLT was measured as loudness discomfort level (LDL), the lowest level of sound deemed uncomfortable, and via a questionnaire on the loudness of sounds in everyday life. Regardless of tinnitus status, ASR amplitude at a given stimulus level increased with decreasing LDL, but showed no relationship to SLT self-reported via the questionnaire. These relationships (or lack thereof) could not be attributed to hearing threshold, age, anxiety, or depression. The results imply that increases in ASR in the animal work signify decreases in LDL specifically and may not correspond to the development of hyperacusis as would be self-reported by a clinic patient.
Sound field diffusivity in NASA Langley Research Center hardwalled acoustic facilities
NASA Technical Reports Server (NTRS)
Mcgary, M. C.
1982-01-01
Cross correlation measurements were performed to determine the quality of the sound fields in the ANRL reverberation room and the ANRL transmission loss facility. The results indicate the level of sound field diffuseness which may be attained in these hardwalled acoustic facilities.
Franken, Tom P; Joris, Philip X; Smith, Philip H
2018-06-14
The brainstem's lateral superior olive (LSO) is thought to be crucial for localizing high-frequency sounds by coding interaural sound level differences (ILD). Its neurons weigh contralateral inhibition against ipsilateral excitation, making their firing rate a function of the azimuthal position of a sound source. Since the very first in vivo recordings, LSO principal neurons have been reported to give sustained and temporally integrating 'chopper' responses to sustained sounds. Neurons with transient responses were observed but largely ignored and even considered a sign of pathology. Using the Mongolian gerbil as a model system, we have obtained the first in vivo patch clamp recordings from labeled LSO neurons and find that principal LSO neurons, the most numerous projection neurons of this nucleus, only respond at sound onset and show fast membrane features suggesting an importance for timing. These results provide a new framework to interpret previously puzzling features of this circuit. © 2018, Franken et al.
Sound Environments Surrounding Preterm Infants Within an Occupied Closed Incubator.
Shimizu, Aya; Matsuo, Hiroya
2016-01-01
Preterm infants often exhibit functional disorders due to the stressful environment in the neonatal intensive care unit (NICU). The sound pressure level (SPL) in the NICU is often much higher than the levels recommended by the American Academy of Pediatrics. Our study aims to describe the SPL and sound frequency levels surrounding preterm infants within closed incubators that utilize high frequency oscillation (HFO) or nasal directional positive airway pressure (nasal-DPAP) respiratory settings. This is a descriptive research study of eight preterm infants (corrected age<33 weeks) exposed to the equipment when placed in an incubator. The actual noise levels were observed and the results were compared to the recommendations made by neonatal experts. Increased noise levels, which have reported to affect neonates' ability to self-regulate, could increase the risk of developing attention deficit disorder, and may result in tachycardia, bradycardia, increased intracranial pressure, and hypoxia. The care provider should closely assess for adverse effects of higher sound levels generated by different modes of respiratory support and take measures to ensure that preterm infants are protected from exposure to noise exceeding the optimal safe levels. Copyright © 2016 Elsevier Inc. All rights reserved.
Using Lighting Levels to Control Sound Levels in a College Library.
ERIC Educational Resources Information Center
Hronek, Beth
1997-01-01
Many libraries have noise problems that can't be fixed with ceiling and carpet treatments, physical arrangement, or sound barriers. This study at Henderson Community College (Henderson KY) attempted to confirm results from an earlier study suggesting that reducing light levels led to reduced noise. The data showed mixed results, but overall the…
Light aircraft sound transmission studies - Noise reduction model
NASA Technical Reports Server (NTRS)
Atwal, Mahabir S.; Heitman, Karen E.; Crocker, Malcolm J.
1987-01-01
Experimental tests conducted on the fuselage of a single-engine Piper Cherokee light aircraft suggest that the cabin interior noise can be reduced by increasing the transmission loss of the dominant sound transmission paths and/or by increasing the cabin interior sound absorption. The validity of using a simple room equation model to predict the cabin interior sound-pressure level for different fuselage and exterior sound field conditions is also presented. The room equation model is based on the sound power flow balance for the cabin space and utilizes the measured transmitted sound intensity data. The room equation model predictions were considered good enough to be used for preliminary acoustical design studies.
Noise levels in the learning-teaching activities in a dental medicine school
NASA Astrophysics Data System (ADS)
Matos, Andreia; Carvalho, Antonio P. O.; Fernandes, Joao C. S.
2002-11-01
The noise levels made by different clinical handpieces and laboratory engines are considered to be the main descriptors of acoustical comfort in learning spaces in a dental medicine school. Sound levels were measured in five types of classrooms and teaching laboratories at the University of Porto Dental Medicine School. Handpiece noise measurements were made while instruments were running free and during operations with cutting tools (tooth, metal, and acrylic). Noise levels were determined using a precision sound level meter, which was positioned at ear level and also at one-meter distance from the operator. Some of the handpieces were brand new and the others had a few years of use. The sound levels encountered were between 60 and 99 dB(A) and were compared with the noise limits in A-weighted sound pressure level for mechanical equipments installed in educational buildings included in the Portuguese Noise Code and in other European countries codes. The daily personal noise exposure levels (LEP,d) of the students and professors were calculated to be between 85 and 90 dB(A) and were compared with the European legal limits. Some noise limits for this type of environment are proposed and suggestions for the improvement of the acoustical environment are given.
Mishima, Riho; Kudo, Takumu; Tsunetsugu, Yuko; Miyazaki, Yoshifumi; Yamamura, Chie; Yamada, Yoshiaki
2004-09-01
Effects of sound generated by a dental turbine and a small stream (murmur) and the effects of no sound (null, control) on heart rate, systolic and diastolic blood pressure, and hemodynamic changes (oxygenated, deoxygenated, and total hemoglobin concentrations) in the frontal cortex were measured in 18 young volunteers. Questionnaires completed by the volunteers were also evaluated. Near-infrared spectroscopy and the Finapres technique were employed to measure hemodynamic and vascular responses, respectively. The subjects assessed the murmur, null, and turbine sounds as "pleasant," "natural," and "unpleasant," respectively. Blood pressures changed in response to the murmur, null, and turbine sound stimuli as expected: lower than the control level, unchanged, and higher than the control level, respectively. Mean blood pressure values tended to increase gradually over the recording time even during the null sound stimulation, possibly because of the recording environment. Oxygenated hemoglobin concentrations decreased drastically in response to the dental turbine sound, while deoxygenated hemoglobin concentrations remained unchanged and thus total hemoglobin concentrations decreased (due to the decreased oxygenated hemoglobin concentrations). Hemodynamic responses to the murmuring sound and the null sound were slight or unchanged, respectively. Surprisingly, heart rate measurements remained fairly stable in response to the stimulatory noises. In conclusion, we demonstrate here that sound generated by a dental turbine may affect cerebral blood flow and metabolism as well as autonomic responses. Copyright 2004 The Society of the Nippon Dental University
Effect of Pile-Driving Sounds on the Survival of Larval Fish.
Bolle, Loes J; de Jong, Christ A F; Bierman, Stijn M; van Beek, Pieter J G; Wessels, Peter W; Blom, Ewout; van Damme, Cindy J G; Winter, Hendrik V; Dekeling, René P A
2016-01-01
Concern exists about the potential effects of pile-driving sounds on fish, but evidence is limited, especially for fish larvae. A device was developed to expose larvae to accurately reproduced pile-driving sounds. Controlled exposure experiments were carried out to examine the lethal effects in common sole larvae. No significant effects were observed at zero-to-peak pressure levels up to 210 dB re 1 μPa(2) and cumulative sound exposure levels up to 206 dB re 1 μPa(2)·s, which is well above the US interim criteria for nonauditory tissue damage in fish. Experiments are presently being carried out for European sea bass and herring larvae.
Assessing the Effectiveness of Ramp-Up During Sonar Operations Using Exposure Models.
von Benda-Beckmann, Alexander M; Wensveen, Paul J; Kvadsheim, Petter H; Lam, Frans-Peter A; Miller, Patrick J O; Tyack, Peter L; Ainslie, Michael A
2016-01-01
Ramp-up procedures are used to mitigate the impact of sound on marine mammals. Sound exposure models combined with observations of marine mammals responding to sound can be used to assess the effectiveness of ramp-up procedures. We found that ramp-up procedures before full-level sonar operations can reduce the risk of hearing threshold shifts with marine mammals, but their effectiveness depends strongly on the responsiveness of the animals. In this paper, we investigated the effect of sonar parameters (source level, pulse-repetition time, ship speed) on sound exposure by using a simple analytical model and highlight the mechanisms that limit the effectiveness of ramp-up procedures.
The NASA-LeRC wind turbine sound prediction code
NASA Technical Reports Server (NTRS)
Viterna, L. A.
1981-01-01
Development of the wind turbine sound prediction code began as part of an effort understand and reduce the noise generated by Mod-1. Tone sound levels predicted with this code are in good agreement with measured data taken in the vicinity Mod-1 wind turbine (less than 2 rotor diameters). Comparison in the far field indicates that propagation effects due to terrain and atmospheric conditions may amplify the actual sound levels by 6 dB. Parametric analysis using the code shows that the predominant contributors to Mod-1 rotor noise are (1) the velocity deficit in the wake of the support tower, (2) the high rotor speed, and (3) off-optimum operation.
Koo, Soo Kweon; Kwon, Soon Bok; Kim, Yang Jae; Moon, J I Seung; Kim, Young Jun; Jung, Sung Hoon
2017-03-01
Snoring is a sign of increased upper airway resistance and is the most common symptom suggestive of obstructive sleep apnea. Acoustic analysis of snoring sounds is a non-invasive diagnostic technique and may provide a screening test that can determine the location of obstruction sites. We recorded snoring sounds according to obstruction level, measured by DISE, using a smartphone and focused on the analysis of formant frequencies. The study group comprised 32 male patients (mean age 42.9 years). The spectrogram pattern, intensity (dB), fundamental frequencies (F 0 ), and formant frequencies (F 1 , F 2 , and F 3 ) of the snoring sounds were analyzed for each subject. On spectrographic analysis, retropalatal level obstruction tended to produce sharp and regular peaks, while retrolingual level obstruction tended to show peaks with a gradual onset and decay. On formant frequency analysis, F 1 (retropalatal level vs. retrolingual level: 488.1 ± 125.8 vs. 634.7 ± 196.6 Hz) and F 2 (retropalatal level vs. retrolingual level: 1267.3 ± 306.6 vs. 1723.7 ± 550.0 Hz) of retrolingual level obstructions showed significantly higher values than retropalatal level obstruction (p < 0.05). This suggests that the upper airway is more severely obstructed with retrolingual level obstruction and that there is a greater change in tongue position. Acoustic analysis of snoring is a non-invasive diagnostic technique that can be easily applied at a relatively low cost. The analysis of formant frequencies will be a useful screening test for the prediction of occlusion sites. Moreover, smartphone can be effective for recording snoring sounds.
Oyster Larvae Settle in Response to Habitat-Associated Underwater Sounds
Lillis, Ashlee; Eggleston, David B.; Bohnenstiehl, DelWayne R.
2013-01-01
Following a planktonic dispersal period of days to months, the larvae of benthic marine organisms must locate suitable seafloor habitat in which to settle and metamorphose. For animals that are sessile or sedentary as adults, settlement onto substrates that are adequate for survival and reproduction is particularly critical, yet represents a challenge since patchily distributed settlement sites may be difficult to find along a coast or within an estuary. Recent studies have demonstrated that the underwater soundscape, the distinct sounds that emanate from habitats and contain information about their biological and physical characteristics, may serve as broad-scale environmental cue for marine larvae to find satisfactory settlement sites. Here, we contrast the acoustic characteristics of oyster reef and off-reef soft bottoms, and investigate the effect of habitat-associated estuarine sound on the settlement patterns of an economically and ecologically important reef-building bivalve, the Eastern oyster (Crassostrea virginica). Subtidal oyster reefs in coastal North Carolina, USA show distinct acoustic signatures compared to adjacent off-reef soft bottom habitats, characterized by consistently higher levels of sound in the 1.5–20 kHz range. Manipulative laboratory playback experiments found increased settlement in larval oyster cultures exposed to oyster reef sound compared to unstructured soft bottom sound or no sound treatments. In field experiments, ambient reef sound produced higher levels of oyster settlement in larval cultures than did off-reef sound treatments. The results suggest that oyster larvae have the ability to respond to sounds indicative of optimal settlement sites, and this is the first evidence that habitat-related differences in estuarine sounds influence the settlement of a mollusk. Habitat-specific sound characteristics may represent an important settlement and habitat selection cue for estuarine invertebrates and could play a role in driving settlement and recruitment patterns in marine communities. PMID:24205381
Oyster larvae settle in response to habitat-associated underwater sounds.
Lillis, Ashlee; Eggleston, David B; Bohnenstiehl, DelWayne R
2013-01-01
Following a planktonic dispersal period of days to months, the larvae of benthic marine organisms must locate suitable seafloor habitat in which to settle and metamorphose. For animals that are sessile or sedentary as adults, settlement onto substrates that are adequate for survival and reproduction is particularly critical, yet represents a challenge since patchily distributed settlement sites may be difficult to find along a coast or within an estuary. Recent studies have demonstrated that the underwater soundscape, the distinct sounds that emanate from habitats and contain information about their biological and physical characteristics, may serve as broad-scale environmental cue for marine larvae to find satisfactory settlement sites. Here, we contrast the acoustic characteristics of oyster reef and off-reef soft bottoms, and investigate the effect of habitat-associated estuarine sound on the settlement patterns of an economically and ecologically important reef-building bivalve, the Eastern oyster (Crassostrea virginica). Subtidal oyster reefs in coastal North Carolina, USA show distinct acoustic signatures compared to adjacent off-reef soft bottom habitats, characterized by consistently higher levels of sound in the 1.5-20 kHz range. Manipulative laboratory playback experiments found increased settlement in larval oyster cultures exposed to oyster reef sound compared to unstructured soft bottom sound or no sound treatments. In field experiments, ambient reef sound produced higher levels of oyster settlement in larval cultures than did off-reef sound treatments. The results suggest that oyster larvae have the ability to respond to sounds indicative of optimal settlement sites, and this is the first evidence that habitat-related differences in estuarine sounds influence the settlement of a mollusk. Habitat-specific sound characteristics may represent an important settlement and habitat selection cue for estuarine invertebrates and could play a role in driving settlement and recruitment patterns in marine communities.
The Warm, Rich Sound of Valve Guitar Amplifiers
ERIC Educational Resources Information Center
Keeports, David
2017-01-01
Practical solid state diodes and transistors have made glass valve technology nearly obsolete. Nevertheless, valves survive largely because electric guitar players much prefer the sound of valve amplifiers to the sound of transistor amplifiers. This paper discusses the introductory-level physics behind that preference. Overdriving an amplifier…
Calcutta metro: is it safe from noise pollution hazards?
Bhattacharya, S K; Bandyopadhyay, P; Kashyap, S K
1996-01-01
A modest assessment of noise was made in Calcutta Metro, India's first ever underground tube rail system, to examine if the range of noise levels present could endanger the hearing sensitivity of workers for the Metro. Sound measuring instruments of a sound level meter, an octave band analyzer, and a sound level calibrator were used for measuring the sound pressure levels in platforms of three stations: Esplanade, Kalighat and Tollygunge. The results indicated that the averaged A-weighted SPLs in these stations were in the range of 84-87 dBA. In the coaches of the moving train the Leq values ranged 92-99 dBA and LNP 105-117 dBA, all exceeding the safe limit of day time noise exposure of 55 dBA and 85 dBA of ACGIH. The SPLs at 4,000 Hz in the coaches were also in excess of safe exposure limit of 79 dB. The findings thus posed a potential threat to the workers.
Noise trauma induced by a mousetrap--sound pressure level measurement of vole captive bolt devices.
Frank, Matthias; Napp, Matthias; Lange, Joern; Grossjohann, Rico; Ekkernkamp, Axel; Beule, Achim G
2010-05-01
While ballistic parameters of vole captive bolt devices have been reported, there is no investigation on their hazardous potential to cause noise trauma. The aim of this experimental study was to measure the sound pressure levels of vole captive bolt devices. Two different shooting devices were examined with a modular precision sound level meter on an outdoor firing range. Measurements were taken in a semi-circular configuration with measuring points 0 degrees in front of the muzzle, 90 degrees at right angle of the muzzle, and 180 degrees behind the shooting device. Distances between muzzle and microphone were 0.5, 1, 2, 10, and 20 m. Sound pressure levels exceeded 130 dB(C) at any measuring point within the 20-m area. Highest measurements (more than 172 dB[C]) were taken in the 0 degrees direction at the 0.5-m distance for both shooting devices proving the hazardous potential of these gadgets to cause noise trauma.
Garrett, J K; Blondel, Ph; Godley, B J; Pikesley, S K; Witt, M J; Johanning, L
2016-09-15
Chronic low-frequency anthropogenic sound, such as shipping noise, may be negatively affecting marine life. The EU's Marine Strategy Framework Directive (MSFD) includes a specific indicator focused on this noise. This indicator is the yearly average sound level in third-octave bands with centre frequencies at 63Hz and 125Hz. These levels are described for Falmouth Bay, UK, an active port at the entrance to the English Channel. Underwater sound was recorded for 30min h(-1) over the period June 2012 to November 2013 for a total of 435days. Mean third-octave levels were louder in the 125-Hz band (annual mean level of 96.0dB re 1μPa) than in the 63-Hz band (92.6dB re 1 μPa). These levels and variations are assessed as a function of seasons, shipping activity and wave height, providing comparison points for future monitoring activities, including the MSFD and emerging international regulation. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Experiments to investigate the acoustic properties of sound propagation
NASA Astrophysics Data System (ADS)
Dagdeviren, Omur E.
2018-07-01
Propagation of sound waves is one of the fundamental concepts in physics. Some of the properties of sound propagation such as attenuation of sound intensity with increasing distance are familiar to everybody from the experiences of daily life. However, the frequency dependence of sound propagation and the effect of acoustics in confined environments are not straightforward to estimate. In this article, we propose experiments, which can be conducted in a classroom environment with commonly available devices such as smartphones and laptops to measure sound intensity level as a function of the distance between the source and the observer and frequency of the sound. Our experiments and deviations from the theoretical calculations can be used to explain basic concepts of sound propagation and acoustics to a diverse population of students.
Sound Symbolic Patterns in Pokémon Names.
Kawahara, Shigeto; Noto, Atsushi; Kumagai, Gakuji
2018-04-11
This paper presents a case study of sound symbolism, cases in which certain sounds tend to be associated with particular meanings. We used the corpus of all Japanese Pokémon names available as of October 2016. We tested the effects of voiced obstruents, mora counts, and vowel quality on Pokémon characters' size, weight, strength parameters, and evolution levels. We found that the number of voiced obstruents in Pokémon names correlates positively with size, weight, evolution levels, and general strength parameters, except for speed. We argue that this result is compatible with the frequency code hypothesis of Ohala. The number of moras in Pokémon names correlates positively with size, weight, evolution levels, and all strength parameters. Vowel height is also shown to have an influence on size and weight - Pokémon characters with initial high vowels tend to be smaller and lighter, although the effect size is not very large. Not only does this paper offer a new case study of sound symbolism, it provides evidence that sound symbolism is at work when naming proper nouns. © 2018 S. Karger AG, Basel.
Consistent modelling of wind turbine noise propagation from source to receiver.
Barlas, Emre; Zhu, Wei Jun; Shen, Wen Zhong; Dag, Kaya O; Moriarty, Patrick
2017-11-01
The unsteady nature of wind turbine noise is a major reason for annoyance. The variation of far-field sound pressure levels is not only caused by the continuous change in wind turbine noise source levels but also by the unsteady flow field and the ground characteristics between the turbine and receiver. To take these phenomena into account, a consistent numerical technique that models the sound propagation from the source to receiver is developed. Large eddy simulation with an actuator line technique is employed for the flow modelling and the corresponding flow fields are used to simulate sound generation and propagation. The local blade relative velocity, angle of attack, and turbulence characteristics are input to the sound generation model. Time-dependent blade locations and the velocity between the noise source and receiver are considered within a quasi-3D propagation model. Long-range noise propagation of a 5 MW wind turbine is investigated. Sound pressure level time series evaluated at the source time are studied for varying wind speeds, surface roughness, and ground impedances within a 2000 m radius from the turbine.
Consistent modelling of wind turbine noise propagation from source to receiver
Barlas, Emre; Zhu, Wei Jun; Shen, Wen Zhong; ...
2017-11-28
The unsteady nature of wind turbine noise is a major reason for annoyance. The variation of far-field sound pressure levels is not only caused by the continuous change in wind turbine noise source levels but also by the unsteady flow field and the ground characteristics between the turbine and receiver. To take these phenomena into account, a consistent numerical technique that models the sound propagation from the source to receiver is developed. Large eddy simulation with an actuator line technique is employed for the flow modelling and the corresponding flow fields are used to simulate sound generation and propagation. Themore » local blade relative velocity, angle of attack, and turbulence characteristics are input to the sound generation model. Time-dependent blade locations and the velocity between the noise source and receiver are considered within a quasi-3D propagation model. Long-range noise propagation of a 5 MW wind turbine is investigated. Sound pressure level time series evaluated at the source time are studied for varying wind speeds, surface roughness, and ground impedances within a 2000 m radius from the turbine.« less
Consistent modelling of wind turbine noise propagation from source to receiver
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barlas, Emre; Zhu, Wei Jun; Shen, Wen Zhong
The unsteady nature of wind turbine noise is a major reason for annoyance. The variation of far-field sound pressure levels is not only caused by the continuous change in wind turbine noise source levels but also by the unsteady flow field and the ground characteristics between the turbine and receiver. To take these phenomena into account, a consistent numerical technique that models the sound propagation from the source to receiver is developed. Large eddy simulation with an actuator line technique is employed for the flow modelling and the corresponding flow fields are used to simulate sound generation and propagation. Themore » local blade relative velocity, angle of attack, and turbulence characteristics are input to the sound generation model. Time-dependent blade locations and the velocity between the noise source and receiver are considered within a quasi-3D propagation model. Long-range noise propagation of a 5 MW wind turbine is investigated. Sound pressure level time series evaluated at the source time are studied for varying wind speeds, surface roughness, and ground impedances within a 2000 m radius from the turbine.« less
Acoustic design by topology optimization
NASA Astrophysics Data System (ADS)
Dühring, Maria B.; Jensen, Jakob S.; Sigmund, Ole
2008-11-01
To bring down noise levels in human surroundings is an important issue and a method to reduce noise by means of topology optimization is presented here. The acoustic field is modeled by Helmholtz equation and the topology optimization method is based on continuous material interpolation functions in the density and bulk modulus. The objective function is the squared sound pressure amplitude. First, room acoustic problems are considered and it is shown that the sound level can be reduced in a certain part of the room by an optimized distribution of reflecting material in a design domain along the ceiling or by distribution of absorbing and reflecting material along the walls. We obtain well defined optimized designs for a single frequency or a frequency interval for both 2D and 3D problems when considering low frequencies. Second, it is shown that the method can be applied to design outdoor sound barriers in order to reduce the sound level in the shadow zone behind the barrier. A reduction of up to 10 dB for a single barrier and almost 30 dB when using two barriers are achieved compared to utilizing conventional sound barriers.
Improving sound absorption property of polyurethane foams doped with natural fiber
NASA Astrophysics Data System (ADS)
Azahari, M. Shafiq M.; Rus, Anika Zafiah M.; Taufiq Zaliran, M.; Kormin, Shaharuddin
2017-08-01
This study investigates the acoustics behavior of wood fibre filler of Red Meranti - filled polyurethane foam as a sound absorbing material. Three different thicknesses have been selected which is 10 mm, 20 mm and 30 mm. By choosing percentage loading of Red Meranti (RM) wood fibre of 5%, 10%, 15% and 20% added with polymer foam is namely as polymer foam (PF) composites of PF5%, PF10%, PF15% and PF20%. The sound absorption coefficient (α) and pore structure of the foam samples have been examined by using Impedance Tube test and Scanning Electron Microscopy (SEM). The results revealed that the highest thickness of highest filler loading (PF20%) gives higher sound absorption coefficient (α). The absorption frequency level is observed at 0.9922 and 0.99889 which contributed from low and high frequency absorption level respectively. The smallest pores size structure was observed with highest filler loading of PF. The higher the thickness and the higher the percentage loading of wood filler gives smaller pore structure, consequently, increased the sound absorption coefficient level.
Wind turbine sound pressure level calculations at dwellings.
Keith, Stephen E; Feder, Katya; Voicescu, Sonia A; Soukhovtsev, Victor; Denning, Allison; Tsang, Jason; Broner, Norm; Leroux, Tony; Richarz, Werner; van den Berg, Frits
2016-03-01
This paper provides calculations of outdoor sound pressure levels (SPLs) at dwellings for 10 wind turbine models, to support Health Canada's Community Noise and Health Study. Manufacturer supplied and measured wind turbine sound power levels were used to calculate outdoor SPL at 1238 dwellings using ISO [(1996). ISO 9613-2-Acoustics] and a Swedish noise propagation method. Both methods yielded statistically equivalent results. The A- and C-weighted results were highly correlated over the 1238 dwellings (Pearson's linear correlation coefficient r > 0.8). Calculated wind turbine SPLs were compared to ambient SPLs from other sources, estimated using guidance documents from the United States and Alberta, Canada.
Effects of Impulsive Pile-Driving Exposure on Fishes.
Casper, Brandon M; Carlson, Thomas J; Halvorsen, Michele B; Popper, Arthur N
2016-01-01
Six species of fishes were tested under aquatic far-field, plane-wave acoustic conditions to answer several key questions regarding the effects of exposure to impulsive pile driving. The issues addressed included which sound levels lead to the onset of barotrauma injuries, how these levels differ between fishes with different types of swim bladders, the recovery from barotrauma injuries, and the potential effects exposure might have on the auditory system. The results demonstrate that the current interim criteria for pile-driving sound exposures are 20 dB or more below the actual sound levels that result in the onset of physiological effects on fishes.
Pressure sound level measurements at an educational environment in Goiânia, Goiás, Brazil
NASA Astrophysics Data System (ADS)
Costa, J. J. L.; do Nascimento, E. O.; de Oliveira, L. N.; Caldas, L. V. E.
2018-03-01
In this work, 25 points located on the ground floor of the Federal Institute of Education, Science and Technology of Goias - IFG - Campus Goiânia, were analyzed in morning periods of two Saturdays. The pressure sound levels were measured at internal and external environments during routine activities seeking to perform an environmental monitoring at this institution. The initial hypothesis was that an amusement park (Mutirama Park) was responsible for originating noise pollution in the institute, but the results showed, within the campus environment, sound pressure levels in accordance with the Municipal legislation of Goiânia for all points.
Marine mammal audibility of selected shallow-water survey sources.
MacGillivray, Alexander O; Racca, Roberto; Li, Zizheng
2014-01-01
Most attention about the acoustic effects of marine survey sound sources on marine mammals has focused on airgun arrays, with other common sources receiving less scrutiny. Sound levels above hearing threshold (sensation levels) were modeled for six marine mammal species and seven different survey sources in shallow water. The model indicated that odontocetes were most likely to hear sounds from mid-frequency sources (fishery, communication, and hydrographic systems), mysticetes from low-frequency sources (sub-bottom profiler and airguns), and pinnipeds from both mid- and low-frequency sources. High-frequency sources (side-scan and multibeam) generated the lowest estimated sensation levels for all marine mammal species groups.
Sound Standards for Schools "Unsound."
ERIC Educational Resources Information Center
Davis, Don
2002-01-01
Criticizes new classroom sound standard proposed by the American National Standards Institute that sets maximum background sound level at 35 decibels (described as "a whisper at 2 meters"). Argues that new standard is too costly for schools to implement, is not recommended by the medical community, and cannot be achieved by construction…
33 CFR 86.09 - Positioning of whistles.
Code of Federal Regulations, 2011 CFR
2011-07-01
... high as practicable on a vessel, in order to reduce interception of the emitted sound by obstructions and also to minimize hearing damage risk to personnel. The sound pressure level of the vessel's own... NAVIGATION RULES ANNEX III: TECHNICAL DETAILS OF SOUND SIGNAL APPLIANCES Whistles § 86.09 Positioning of...
33 CFR 86.09 - Positioning of whistles.
Code of Federal Regulations, 2010 CFR
2010-07-01
... high as practicable on a vessel, in order to reduce interception of the emitted sound by obstructions and also to minimize hearing damage risk to personnel. The sound pressure level of the vessel's own... NAVIGATION RULES ANNEX III: TECHNICAL DETAILS OF SOUND SIGNAL APPLIANCES Whistles § 86.09 Positioning of...
ERIC Educational Resources Information Center
The American School Board Journal, 1968
1968-01-01
Problems of sound insulation and control particularly in areas where there is a high level in exterior noise conditions, resulted in this study to determine approaches to sound control in school construction. After a general discussion of noise problems in school districts and teaching situations, two examples of sound control solutions are…
40 CFR 202.21 - Standard for operation under stationary test.
Code of Federal Regulations, 2012 CFR
2012-07-01
... sound level in excess of 88 dB(A) measured on an open site with fast meter response at 50 feet from the... applicable which generates a sound level in excess of 85 dB(A) measured on an open site with fast meter...
Solan, Martin; Hauton, Chris; Godbold, Jasmin A.; Wood, Christina L.; Leighton, Timothy G.; White, Paul
2016-01-01
Coastal and shelf environments support high levels of biodiversity that are vital in mediating ecosystem processes, but they are also subject to noise associated with mounting levels of offshore human activity. This has the potential to alter the way in which species interact with their environment, compromising the mediation of important ecosystem properties. Here, we show that exposure to underwater broadband sound fields that resemble offshore shipping and construction activity can alter sediment-dwelling invertebrate contributions to fluid and particle transport - key processes in mediating benthic nutrient cycling. Despite high levels of intra-specific variability in physiological response, we find that changes in the behaviour of some functionally important species can be dependent on the class of broadband sound (continuous or impulsive). Our study provides evidence that exposing coastal environments to anthropogenic sound fields is likely to have much wider ecosystem consequences than are presently acknowledged. PMID:26847483
Sound radiation from randomly vibrating beams of finite circular cross section
NASA Technical Reports Server (NTRS)
Sutterlin, M. W.; Pierce, A. D.
1976-01-01
The radiation of sound from vibrating cylindrical beams is analyzed based on the frequency of the beam vibrations and the physical characteristics of the beam and its surroundings. A statistical analysis of random beam vibrations allows this result to be independent of the boundary conditions at the ends of the beam. The acoustic power radiated by the beam can be determined from a knowledge of the frequency band vibration data without a knowledge of the individual modal vibration amplitudes. A practical example of the usefulness of this technique is provided by the application of the theoretical calculations to the prediction of the octave band acoustic power output of the picking sticks of an automatic textile loom. Calculations are made of the expected octave band sound pressure levels based on measured acceleration data. These theoretical levels are subsequently compared with actual sound pressure level measurements of loom noise.
NASA Astrophysics Data System (ADS)
Hustim, M.; Arifin, Z.; Aly, S. H.; Ramli, M. I.; Zakaria, R.; Liputo, A.
2018-04-01
This research aimed to predict the noise produced by the traffic in the road network in Makassar City using ASJ-RTN Model 2008 by calculating the horn sound. Observations were taken at 37 survey points on road side. The observations were conducted at 06.00 - 18.00 and 06.00 - 21.00 which research objects were motorcycle (MC), light vehicle (LV) and heavy vehicle (HV). The observed data were traffic volume, vehicle speed, number of horn and traffic noise using Sound Level Meter Tenmars TM-103. The research result indicates that prediction noise model by calculating the horn sound produces the average noise level value of 78.5 dB having the Pearson’s correlation and RMSE of 0.95 and 0.87. Therefore, ASJ-RTN Model 2008 prediction model by calculating the horn sound is said to be sufficiently good for predicting noise level.
The warm, rich sound of valve guitar amplifiers
NASA Astrophysics Data System (ADS)
Keeports, David
2017-03-01
Practical solid state diodes and transistors have made glass valve technology nearly obsolete. Nevertheless, valves survive largely because electric guitar players much prefer the sound of valve amplifiers to the sound of transistor amplifiers. This paper discusses the introductory-level physics behind that preference. Overdriving an amplifier adds harmonics to an input sound. While a moderately overdriven valve amplifier produces strong even harmonics that enhance a sound, an overdriven transistor amplifier creates strong odd harmonics that can cause dissonance. The functioning of a triode valve explains its creation of even and odd harmonics. Music production software enables the examination of both the wave shape and the harmonic content of amplified sounds.
Fredriksson, Sofie; Hammar, Oscar; Torén, Kjell; Tenenbaum, Artur; Waye, Kerstin Persson
2015-01-01
Objective There is a lack of research on effects of occupational noise exposure in traditionally female-dominated workplaces. Therefore, the aim of this study was to assess risk of noise-induced hearing-related symptoms among obstetrics personnel. Design A cross-sectional study was performed at an obstetric ward in Sweden including a questionnaire among all employees and sound level measurements in 61 work shifts at the same ward. Participants 115 female employees responded to a questionnaire (72% of all 160 employees invited). Main outcome measures Self-reported hearing-related symptoms in relation to calculated occupational noise exposure dose and measured sound levels. Results Sound levels exceeded the 80 dB LAeq limit for protection of hearing in 46% of the measured work shifts. One or more hearing-related symptoms were reported by 55% of the personnel. In logistic regression models, a significant association was found between occupational noise exposure dose and tinnitus (OR=1.04, 95% CI 1.00 to 1.09) and sound-induced auditory fatigue (OR=1.04, 95% CI 1.00 to 1.07). Work-related stress and noise annoyance at work were reported by almost half of the personnel. Sound-induced auditory fatigue was associated with work-related stress and noise annoyance at work, although stress slightly missed significance in a multivariable model. No significant interactions were found. Conclusions This study presents new results showing that obstetrics personnel are at risk of noise-induced hearing-related symptoms. Current exposure levels at the workplace are high and occupational noise exposure dose has significant effects on tinnitus and sound-induced auditory fatigue among the personnel. These results indicate that preventative action regarding noise exposure is required in obstetrics care and that risk assessments may be needed in previously unstudied non-industrial communication-intense sound environments. PMID:25818267
Sound source localization inspired by the ears of the Ormia ochracea
NASA Astrophysics Data System (ADS)
Kuntzman, Michael L.; Hall, Neal A.
2014-07-01
The parasitoid fly Ormia ochracea has the remarkable ability to locate crickets using audible sound. This ability is, in fact, remarkable as the fly's hearing mechanism spans only 1.5 mm which is 50× smaller than the wavelength of sound emitted by the cricket. The hearing mechanism is, for all practical purposes, a point in space with no significant interaural time or level differences to draw from. It has been discovered that evolution has empowered the fly with a hearing mechanism that utilizes multiple vibration modes to amplify interaural time and level differences. Here, we present a fully integrated, man-made mimic of the Ormia's hearing mechanism capable of replicating the remarkable sound localization ability of the special fly. A silicon-micromachined prototype is presented which uses multiple piezoelectric sensing ports to simultaneously transduce two orthogonal vibration modes of the sensing structure, thereby enabling simultaneous measurement of sound pressure and pressure gradient.
Chouard, C H
2001-07-01
Noise is responsible for cochlear and general damages. Hearing loss and tinnitus greatly depend on sound intensity and duration. Short-duration sound of sufficient intensity (gunshot or explosion) will not be described because they are not currently encountered in our normal urban environment. Sound levels of less than 75 d (A) are unlikely to cause permanent hearing loss, while sound levels of about 85 d (A) with exposures of 8 h per day will produce permanent hearing loss after many years. Popular and largely amplified music is today one of the most dangerous causes of noise induced hearing loss. The intensity of noises (airport, highway) responsible for stress and general consequences (cardiovascular) is generally lower. Individual noise sensibility depends on several factors. Strategies to prevent damage from sound exposure should include the use of individual hearing protection devices, education programs beginning with school-age children, consumer guidance, increased product noise labelling, and hearing conservation programs for occupational settings.
Persson Waye, Kerstin; Elmenhorst, Eva-Maria; Croy, Ilona; Pedersen, Eja
2013-12-01
Uninterrupted sleep is of vital importance for restoration and regaining health. In intensive care units (ICUs) where recovering and healing is crucial, patients' sleep often is fragmented and disturbed due to noise from activities from oneself, other patients, and alarms. The aim of our study was to explore if sleep could be improved by modifying the sound environment in a way that is practically feasible in ICUs. We studied the effects of originally recorded ICU noise and peak reduced ICU noise on sleep in healthy male participants. Sleep was registered with polysomnography (PSG) during four nights: one adaptation night, one reference (REF) night, and the two exposed nights with similar equivalent sound levels (47dB LAeq) but different maximum sound levels (56- vs 64-dB LAFmax). The participants answered questionnaires and saliva cortisol was sampled in the morning. During ICU exposure nights, sleep was more fragmented with less slow-wave sleep (SWS), more arousals, and more time awake. The effects of reduced maximum sound level were minor. The subjective data supported the polysomnographic findings, though cortisol levels were not significantly affected by the exposure conditions. Noise in ICUs impairs sleep and the reduction of maximal A-weighted levels from 64 to 56dB is not enough to have a clear improved effect on sleep quality. Copyright © 2013 Elsevier B.V. All rights reserved.
Peak Sound Pressure Levels and Associated Auditory Risk from an H[subscript 2]-Air "Egg-Splosion"
ERIC Educational Resources Information Center
Dolhun, John J.
2016-01-01
The noise level from exploding chemical demonstrations and the effect they could have on audiences, especially young children, needs attention. Auditory risk from H[subscript 2]- O2 balloon explosions have been studied, but no studies have been done on H[subscript 2]-air "eggsplosions." The peak sound pressure level (SPL) was measured…
Sound levels in conservative dentistry and endodontics clinic
Dutta, Arindam; Mala, Kundabala; Acharya, Shashi Rashmi
2013-01-01
Aim: To evaluate the sound levels generated in dental clinics of conservative dentistry and endodontics. Material and Methods: A decibel-meter with digital readout was used to measure sound levels at different time intervals at the chairside and at the center of the clinic. Minimum and maximum readings during a 3 min interval were recorded. Results: In the post-graduate (PG) clinic, there was significant difference in noise levels between the chairside (66-81 dB[A]) and the center of the clinic (66-67 dB[A]) at certain times. In the under graduate (UG) clinic, noise levels with suction and either high/slow speed handpieces (67-80 dB[A]) were significantly higher than the center of clinic. Suction alone in the UG clinic (63-75 dB[A]) was significantly quieter than in the PG clinic (69-79 dB[A]). Conclusions: (1) Mean sound levels in the working clinics ranged from 63.0 dB[A] to 81.5 dB[A]. These are within the recommended range for dental equipment. (2) With suction and either low/high speed handpiece combination, the PG clinic was significantly noisier than the UG clinic at several time periods. PMID:23716962
What is a melody? On the relationship between pitch and brightness of timbre.
Cousineau, Marion; Carcagno, Samuele; Demany, Laurent; Pressnitzer, Daniel
2013-01-01
Previous studies showed that the perceptual processing of sound sequences is more efficient when the sounds vary in pitch than when they vary in loudness. We show here that sequences of sounds varying in brightness of timbre are processed with the same efficiency as pitch sequences. The sounds used consisted of two simultaneous pure tones one octave apart, and the listeners' task was to make same/different judgments on pairs of sequences varying in length (one, two, or four sounds). In one condition, brightness of timbre was varied within the sequences by changing the relative level of the two pure tones. In other conditions, pitch was varied by changing fundamental frequency, or loudness was varied by changing the overall level. In all conditions, only two possible sounds could be used in a given sequence, and these two sounds were equally discriminable. When sequence length increased from one to four, discrimination performance decreased substantially for loudness sequences, but to a smaller extent for brightness sequences and pitch sequences. In the latter two conditions, sequence length had a similar effect on performance. These results suggest that the processes dedicated to pitch and brightness analysis, when probed with a sequence-discrimination task, share unexpected similarities.
Nonlinear acoustics in cicada mating calls enhance sound propagation.
Hughes, Derke R; Nuttall, Albert H; Katz, Richard A; Carter, G Clifford
2009-02-01
An analysis of cicada mating calls, measured in field experiments, indicates that the very high levels of acoustic energy radiated by this relatively small insect are mainly attributed to the nonlinear characteristics of the signal. The cicada emits one of the loudest sounds in all of the insect population with a sound production system occupying a physical space typically less than 3 cc. The sounds made by tymbals are amplified by the hollow abdomen, functioning as a tuned resonator, but models of the signal based solely on linear techniques do not fully account for a sound radiation capability that is so disproportionate to the insect's size. The nonlinear behavior of the cicada signal is demonstrated by combining the mutual information and surrogate data techniques; the results obtained indicate decorrelation when the phase-randomized and non-phase-randomized data separate. The Volterra expansion technique is used to fit the nonlinearity in the insect's call. The second-order Volterra estimate provides further evidence that the cicada mating calls are dominated by nonlinear characteristics and also suggests that the medium contributes to the cicada's efficient sound propagation. Application of the same principles has the potential to improve radiated sound levels for sonar applications.
Wang, Ningqian; Wang, Xiao; Yang, Xiaoli; Tang, Jie; Xiao, Zhongju
2014-01-16
In this study, we adopted iso-frequency pure tone bursts to investigate the interdependent effects of sound amplitude/intensity and duration on mice inferior colliculus (IC) neuronal onset responses. On the majority of the sampled neurons (n=57, 89.1%), sound amplitude and duration had effects on the neuronal response to each other by showing complex changes of the rat-intensity function/duration selectivity types and/or best amplitudes (BAs)/durations (BDs), evaluated by spike counts. These results suggested that the balance between the excitatory and inhibitory inputs set by one acoustic parameter, amplitude or duration, affected the neuronal spike counts responses to the other. Neuronal duration selectivity types were altered easily by the low-amplitude sounds while the changes of rate-intensity function types had no obvious preferred stimulus durations. However, the first spike latencies (FSLs) of the onset response neurons were relative stable to iso-amplitude sound durations and changing systematically along with the sound levels. The superimposition of FSL and duration threshold (DT) as a function of stimulus amplitude after normalization indicated that the effects of the sound levels on FSLs are considered on DT actually. © 2013 Published by Elsevier B.V.
Underwater sounds near a fuel receiving facility in western Hong Kong: relevance to dolphins.
Würsig, B; Greene, C R
2002-08-01
Western Hong Kong is home to two species of marine mammals: Indo-Pacific humpbacked dolphins (Sousa chinensis) and finless porpoises (Neophocaena phocaenoides). Both are threatened in many parts of their range in southeast Asia [for example, International Biological Research Institute Reports 9 (1997), 41; Asian Marine Biology 14 (1997) 111]. In 1998, when the new Hong Kong International Airport opened in western Hong Kong, small tankers (about 100 m long, cargo capacity about 6300 metric tons) began delivering fuel to the Aviation Fuel Receiving Facility (AFRF) just off Sha Chau Island, north of the airport. Calibrated sound recordings were taken over a 4-day period from a quiet, anchored boat at distances 80-2000 m from aviation fuel delivery activities at the AFRF. From the recordings, 143 sections were selected for analysis. Narrowband spectral densities on the sound pressures were computed, and one-third octave band levels were derived for center frequencies from 10 to 16,000 Hz. Broadband levels, viz. 10-20,000 Hz. were also computed. The results showed that the Sha Chau area is normally noisy underwater, with the lowest broadband levels measured corresponding to those expected during a storm at sea (sea state 6). This background noise is believed to come largely from heavy vessel traffic in the Urmston Road to the north and east of Sha Chau and from vessels in the Pearl River Estuary to the West. The sound levels from the AFRF tankers are comparable to the levels measured from similar- and smaller-sized supply vessels supporting offshore oil exploration. The strongest sounds recorded were from a tanker leaving the AFRF at distance 100 m from the hydrophone, for which the one-third octave band level at 100 Hz was 141 dB re 1 microPa (spectrum level 127 dB re 1 microPa2/Hz) and the 10-20,000 Hz broadband level was 146 dB. At distances of 100 m or more and frequencies above 300 Hz, the one-third octave band levels were less than 130 dB (spectrum level 111 dB re 1 microPa2/Hz) and decreased with increasing frequency and distance. At distances greater than about 500 m, AFRF-associated sounds were negligible, masked by the generally high noise level of the area and attenuated by poor transmission in the very shallow water (<10 m). Because it is believed that humpbacked dolphins and finless porpoises are not very sensitive to sounds below 300 Hz, the Airport Authority Hong Kong (AA) stipulated that dedicated terminal vessels not radiate underwater sounds at spectrum levels greater than 110 dB re 1 microPa2/Hz at frequencies above 300 Hz and distances greater than 300 m. The spectrum levels at 300 Hz and higher frequencies of sounds from the tankers arriving, departing, or off-loading at AFRF were less than 110 dB re 1 microPa2/Hz even at distances of 200 m or less. The AA stipulation was met. However, it is presently unknown whether the generally strong noise levels of western Hong Kong inhibit acoustically based feeding and communication, or result in increased stress or permanent shifts in hearing thresholds.
Debusschere, Elisabeth; De Coensel, Bert; Bajek, Aline; Botteldooren, Dick; Hostens, Kris; Vanaverbeke, Jan; Vandendriessche, Sofie; Van Ginderdeuren, Karl; Vincx, Magda; Degraer, Steven
2014-01-01
Impact assessments of offshore wind farm installations and operations on the marine fauna are performed in many countries. Yet, only limited quantitative data on the physiological impact of impulsive sounds on (juvenile) fishes during pile driving of offshore wind farm foundations are available. Our current knowledge on fish injury and mortality due to pile driving is mainly based on laboratory experiments, in which high-intensity pile driving sounds are generated inside acoustic chambers. To validate these lab results, an in situ field experiment was carried out on board of a pile driving vessel. Juvenile European sea bass (Dicentrarchus labrax) of 68 and 115 days post hatching were exposed to pile-driving sounds as close as 45 m from the actual pile driving activity. Fish were exposed to strikes with a sound exposure level between 181 and 188 dB re 1 µPa2.s. The number of strikes ranged from 1739 to 3067, resulting in a cumulative sound exposure level between 215 and 222 dB re 1 µPa2.s. Control treatments consisted of fish not exposed to pile driving sounds. No differences in immediate mortality were found between exposed and control fish groups. Also no differences were noted in the delayed mortality up to 14 days after exposure between both groups. Our in situ experiments largely confirm the mortality results of the lab experiments found in other studies. PMID:25275508
Categorization of common sounds by cochlear implanted and normal hearing adults.
Collett, E; Marx, M; Gaillard, P; Roby, B; Fraysse, B; Deguine, O; Barone, P
2016-05-01
Auditory categorization involves grouping of acoustic events along one or more shared perceptual dimensions which can relate to both semantic and physical attributes. This process involves both high level cognitive processes (categorization) and low-level perceptual encoding of the acoustic signal, both of which are affected by the use of a cochlear implant (CI) device. The goal of this study was twofold: I) compare the categorization strategies of CI users and normal hearing listeners (NHL) II) investigate if any characteristics of the raw acoustic signal could explain the results. 16 experienced CI users and 20 NHL were tested using a Free-Sorting Task of 16 common sounds divided into 3 predefined categories of environmental, musical and vocal sounds. Multiple Correspondence Analysis (MCA) and Hierarchical Clustering based on Principal Components (HCPC) show that CI users followed a similar categorization strategy to that of NHL and were able to discriminate between the three different types of sounds. However results for CI users were more varied and showed less inter-participant agreement. Acoustic analysis also highlighted the average pitch salience and average autocorrelation peak as being important for the perception and categorization of the sounds. The results therefore show that on a broad level of categorization CI users may not have as many difficulties as previously thought in discriminating certain kinds of sound; however the perception of individual sounds remains challenging. Copyright © 2016 Elsevier B.V. All rights reserved.
Evaluating the performance of active noise control systems in commercial and industrial applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Depies, C.; Deneen, S.; Lowe, M.
1995-06-01
Active sound cancellation technology is increasingly being used to quiet commercial and industrial air-moving devices. Engineers and designers are implementing active or combination active/passive technology to control sound quality in the workplace and the acoustical environment in residential areas near industrial facilities. Sound level measurements made before and after the installation of active systems have proved that significant improvements in sound quality can be obtained even if there is little or no change in the NC/RC or dBA numbers. Noise produced by centrifugal and vane-axial fans, pumps and blowers, commonly used for ventilation and material movement in industry, are frequentlymore » dominated by high amplitude, tonal noise at low frequencies. And the low-frequency noise produced by commercial air handlers often has less tonal and more broadband characteristics, resulting in audible duct rumble noise and objectionable room spectrums. Because the A-weighting network, which is commonly used for industrial noise measurements, de-emphasizes low frequencies, its single number rating can be misleading in terms of judging the overall subjective sound quality in impacted areas and assessing the effectiveness of noise control measures. Similarly, NC values, traditionally used for commercial HVAC acoustical design criteria, can be governed by noise at any frequency and cannot accurately depict human judgment of the aural comfort level. Analyses of frequency spectrum characteristics provide the most effective means of assessing sound quality and determining mitigative measures for achieving suitable background sound levels.« less
Maccariello, Carolina Elisabetta Martins; Franzini de Souza, Carla Caroline; Morena, Laura; Dias, Daniel Penteado Martins; Medeiros, Magda Alves de
2018-03-15
Sound stimuli such as fireworks, firearms, and claps of thunder have been used as a stress reactivity model for dogs. Acupuncture has been widely used to treat and prevent physiological and behavioural disorders induced by stress. Our study aims to evaluate the effects of acupuncture on cardiac autonomic modulation (heart rate variability - HRV), behavioural (reactivity) and endocrine (cortisol levels) responses in dogs exposed to sounds of thunder. Twenty-four laboratory beagles (12 males and 12 females, 1-6years old) with no history of phobia to thunder were subjected to a sound stimulus that consisted of a standardized recording of thunder over a 150s period with a maximum intensity of 103-104dB. Before the sound, the dogs underwent a 20-minute session of needle insertion at acupuncture points Yintang, GV20, HT7, PC6 and ST36 (ACUP), in non-points (NP) or left undisturbed (CTL). Cardiac intervals were recorded using a frequency meter (RS 800cx, Polar, Kempele, Finland) to evaluate the HRV, and the data were later analysed using CardioSeries v2.4.1 software. Acupuncture (ACUP) changed the sympathovagal balance with a shift towards parasympathetic modulation, reducing the prompt sound-induced increase in LF/HF (low frequency/high frequency) ratio and in the power of the LF band of the cardiac interval spectrum, and decreased the power of the HF band of the cardiac interval spectrum (p<0.05); however there was no change in the heart rate. Acupuncture reduced the behavioural response induced by sounds of thunder (when all behavioural parameters were considered together) and the behaviours hiding, restlessness, bolting and running around (when the parameters were analysed separately (p<0.05). There were no changes in cortisol levels due to the sound stimulus or acupuncture. Our results demonstrate that a session of acupuncture prior to sound stimulus can reduce cardiac autonomic and behavioural responses, without changing cortisol levels in beagles. Copyright © 2018 Elsevier Inc. All rights reserved.
A Flexible 360-Degree Thermal Sound Source Based on Laser Induced Graphene
Tao, Lu-Qi; Liu, Ying; Ju, Zhen-Yi; Tian, He; Xie, Qian-Yi; Yang, Yi; Ren, Tian-Ling
2016-01-01
A flexible sound source is essential in a whole flexible system. It’s hard to integrate a conventional sound source based on a piezoelectric part into a whole flexible system. Moreover, the sound pressure from the back side of a sound source is usually weaker than that from the front side. With the help of direct laser writing (DLW) technology, the fabrication of a flexible 360-degree thermal sound source becomes possible. A 650-nm low-power laser was used to reduce the graphene oxide (GO). The stripped laser induced graphene thermal sound source was then attached to the surface of a cylindrical bottle so that it could emit sound in a 360-degree direction. The sound pressure level and directivity of the sound source were tested, and the results were in good agreement with the theoretical results. Because of its 360-degree sound field, high flexibility, high efficiency, low cost, and good reliability, the 360-degree thermal acoustic sound source will be widely applied in consumer electronics, multi-media systems, and ultrasonic detection and imaging. PMID:28335239
Time course of dynamic range adaptation in the auditory nerve
Wang, Grace I.; Dean, Isabel; Delgutte, Bertrand
2012-01-01
Auditory adaptation to sound-level statistics occurs as early as in the auditory nerve (AN), the first stage of neural auditory processing. In addition to firing rate adaptation characterized by a rate decrement dependent on previous spike activity, AN fibers show dynamic range adaptation, which is characterized by a shift of the rate-level function or dynamic range toward the most frequently occurring levels in a dynamic stimulus, thereby improving the precision of coding of the most common sound levels (Wen B, Wang GI, Dean I, Delgutte B. J Neurosci 29: 13797–13808, 2009). We investigated the time course of dynamic range adaptation by recording from AN fibers with a stimulus in which the sound levels periodically switch from one nonuniform level distribution to another (Dean I, Robinson BL, Harper NS, McAlpine D. J Neurosci 28: 6430–6438, 2008). Dynamic range adaptation occurred rapidly, but its exact time course was difficult to determine directly from the data because of the concomitant firing rate adaptation. To characterize the time course of dynamic range adaptation without the confound of firing rate adaptation, we developed a phenomenological “dual adaptation” model that accounts for both forms of AN adaptation. When fitted to the data, the model predicts that dynamic range adaptation occurs as rapidly as firing rate adaptation, over 100–400 ms, and the time constants of the two forms of adaptation are correlated. These findings suggest that adaptive processing in the auditory periphery in response to changes in mean sound level occurs rapidly enough to have significant impact on the coding of natural sounds. PMID:22457465
Characterizing noise and perceived work environment in a neurological intensive care unit.
Ryherd, Erica E; Waye, Kerstin Persson; Ljungkvist, Linda
2008-02-01
The hospital sound environment is complex. Alarms, medical equipment, activities, and ventilation generate noise that may present occupational problems as well as hinder recovery among patients. In this study, sound measurements and occupant evaluations were conducted in a neurological intensive care unit. Staff completed questionnaires regarding psychological and physiological reactions to the sound environment. A-weighted equivalent, minimum, and maximum (L(Aeq),L(AFMin),L(AFMax)) and C-weighted peak (L(CPeak)) sound pressure levels were measured over five days at patient and staff locations. Acoustical descriptors that may be explored further were investigated, including level distributions, restorative periods, and spectral content. Measurements near the patients showed average L(Aeq) values of 53-58 dB. The mean length of restorative periods (L(Aeq) below 50 dB for more than 5 min) was 9 and 13 min for day and night, respectively. Ninety percent of the time, the L(AFMax) levels exceeded 50 dB and L(CPeak) exceeded 70 dB. Dosimeters worn by the staff revealed higher noise levels. Personnel perceived the noise as contributing to stress symptoms. Compared to the majority of previous studies, this study provides a more thorough description of intensive care noise and aids in understanding how the sound environment may be disruptive to occupants.
Perceptual assessment of quality of urban soundscapes with combined noise sources and water sounds.
Jeon, Jin Yong; Lee, Pyoung Jik; You, Jin; Kang, Jian
2010-03-01
In this study, urban soundscapes containing combined noise sources were evaluated through field surveys and laboratory experiments. The effect of water sounds on masking urban noises was then examined in order to enhance the soundscape perception. Field surveys in 16 urban spaces were conducted through soundwalking to evaluate the annoyance of combined noise sources. Synthesis curves were derived for the relationships between noise levels and the percentage of highly annoyed (%HA) and the percentage of annoyed (%A) for the combined noise sources. Qualitative analysis was also made using semantic scales for evaluating the quality of the soundscape, and it was shown that the perception of acoustic comfort and loudness was strongly related to the annoyance. A laboratory auditory experiment was then conducted in order to quantify the total annoyance caused by road traffic noise and four types of construction noise. It was shown that the annoyance ratings were related to the types of construction noise in combination with road traffic noise and the level of the road traffic noise. Finally, water sounds were determined to be the best sounds to use for enhancing the urban soundscape. The level of the water sounds should be similar to or not less than 3 dB below the level of the urban noises.
An Inexpensive Group FM Amplification System for the Classroom.
ERIC Educational Resources Information Center
Worner, William A.
1988-01-01
An inexpensive FM amplification system was developed to enhance auditory learning in classrooms for the hearing impaired. Evaluation indicated that the system equalizes the sound pressure level throughout the room, with the increased sound pressure level falling in the range of 70 to 73 decibels. (Author/DB)
40 CFR 204.55-2 - Requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... § 204.54. (c)(1) In lieu of testing compressors of every configuration, as described in paragraph (b) of... category which emits the highest sound level in dBA based on best technical judgment, emission test data... section as having the highest sound level (estimated or actual) within the category. (iv) Compliance of...
40 CFR 205.55-2 - Compliance with standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... as described in paragraph (b) of this section, the manufacturer may elect to verify the configuration... the highest sound pressure level (dBA) based on his best technical judgment and/or emission test data... section as having the highest sound pressure level (estimated or actual) within the category; and (iv...
40 CFR 205.55-2 - Compliance with standards.
Code of Federal Regulations, 2011 CFR
2011-07-01
... as described in paragraph (b) of this section, the manufacturer may elect to verify the configuration... the highest sound pressure level (dBA) based on his best technical judgment and/or emission test data... section as having the highest sound pressure level (estimated or actual) within the category; and (iv...
40 CFR 204.55-2 - Requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... § 204.54. (c)(1) In lieu of testing compressors of every configuration, as described in paragraph (b) of... category which emits the highest sound level in dBA based on best technical judgment, emission test data... section as having the highest sound level (estimated or actual) within the category. (iv) Compliance of...
49 CFR 325.37 - Location and operation of sound level measurement system; highway operations.
Code of Federal Regulations, 2013 CFR
2013-10-01
... system; highway operations. 325.37 Section 325.37 Transportation Other Regulations Relating to...; Highway Operations § 325.37 Location and operation of sound level measurement system; highway operations..., the holder must orient himself/herself relative to the highway in a manner consistent with the...
49 CFR 325.37 - Location and operation of sound level measurement system; highway operations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... system; highway operations. 325.37 Section 325.37 Transportation Other Regulations Relating to...; Highway Operations § 325.37 Location and operation of sound level measurement system; highway operations..., the holder must orient himself/herself relative to the highway in a manner consistent with the...
49 CFR 325.37 - Location and operation of sound level measurement system; highway operations.
Code of Federal Regulations, 2014 CFR
2014-10-01
... system; highway operations. 325.37 Section 325.37 Transportation Other Regulations Relating to...; Highway Operations § 325.37 Location and operation of sound level measurement system; highway operations..., the holder must orient himself/herself relative to the highway in a manner consistent with the...
Sperm whales reduce foraging effort during exposure to 1-2 kHz sonar and killer whale sounds.
Isojunno, Saana; Cure, Charlotte; Kvadsheim, Petter Helgevold; Lam, Frans-Peter Alexander; Tyack, Peter Lloyd; Wensveen, Paul Jacobus; Miller, Patrick James O'Malley
2016-01-01
The time and energetic costs of behavioral responses to incidental and experimental sonar exposures, as well as control stimuli, were quantified using hidden state analysis of time series of acoustic and movement data recorded by tags (DTAG) attached to 12 sperm whales (Physeter macrocephalus) using suction cups. Behavioral state transition modeling showed that tagged whales switched to a non-foraging, non-resting state during both experimental transmissions of low-frequency active sonar from an approaching vessel (LFAS; 1-2 kHz, source level 214 dB re 1 µPa m, four tag records) and playbacks of potential predator (killer whale, Orcinus orca) sounds broadcast at naturally occurring sound levels as a positive control from a drifting boat (five tag records). Time spent in foraging states and the probability of prey capture attempts were reduced during these two types of exposures with little change in overall locomotion activity, suggesting an effect on energy intake with no immediate compensation. Whales switched to the active non-foraging state over received sound pressure levels of 131-165 dB re 1 µPa during LFAS exposure. In contrast, no changes in foraging behavior were detected in response to experimental negative controls (no-sonar ship approach or noise control playback) or to experimental medium-frequency active sonar exposures (MFAS; 6-7 kHz, source level 199 re 1 µPa m, received sound pressure level [SPL] = 73-158 dB re 1 µPa). Similarly, there was no reduction in foraging effort for three whales exposed to incidental, unidentified 4.7-5.1 kHz sonar signals received at lower levels (SPL = 89-133 dB re 1 µPa). These results demonstrate that similar to predation risk, exposure to sonar can affect functional behaviors, and indicate that increased perception of risk with higher source level or lower frequency may modulate how sperm whales respond to anthropogenic sound.
Urban Noise Recorded by Stationary Monitoring Stations
NASA Astrophysics Data System (ADS)
Bąkowski, Andrzej; Radziszewski, Leszek; Dekýš, Vladimir
2017-10-01
The paper presents the analysis results of equivalent sound level recorded by two road traffic noise monitoring stations. The stations were located in Kielce (an example of a medium-size town in Poland) at the roads in the town in the direction of Łódź and Lublin. The measurements were carried out through stationary stations monitoring the noise and traffic of motor vehicles. The RMS values based on A-weighted sound level were recorded every 1 s in the buffer and the results were registered every 1 min over the period of investigations. The registered data were the basis for calculating the equivalent sound level for three time intervals: from 6:00 to 18:00, from 18:00 to 22:00 and from 22:00 to 6:00. Analysis included the values of the equivalent sound level recorded for different days of the week split into 24h periods, nights, days and evenings. The data analysed included recordings from 2013. The agreement of the distribution of the variable under analysis with normal distribution was evaluated. It was demonstrated that in most cases (for both roads) there was sufficient evidence to reject the null hypothesis at the significance level of 0.05. It was noted that compared with Łódź Road, in the case of Lublin Road data, more cases were recorded for which the null hypothesis could not be rejected. Uncertainties of the equivalent sound level measurements were compared within the periods under analysis. The standard deviation, coefficient of variation, the positional coefficient of variation, the quartile deviation was proposed for performing a comparative analysis of the obtained data scattering. The investigations indicated that the recorded data varied depending on the traffic routes and time intervals. The differences concerned the values of uncertainties and coefficients of variation of the equivalent sound levels.
Spherical loudspeaker array for local active control of sound.
Rafaely, Boaz
2009-05-01
Active control of sound has been employed to reduce noise levels around listeners' head using destructive interference from noise-canceling sound sources. Recently, spherical loudspeaker arrays have been studied as multiple-channel sound sources, capable of generating sound fields with high complexity. In this paper, the potential use of a spherical loudspeaker array for local active control of sound is investigated. A theoretical analysis of the primary and secondary sound fields around a spherical sound source reveals that the natural quiet zones for the spherical source have a shell-shape. Using numerical optimization, quiet zones with other shapes are designed, showing potential for quiet zones with extents that are significantly larger than the well-known limit of a tenth of a wavelength for monopole sources. The paper presents several simulation examples showing quiet zones in various configurations.
Schreur, H J; Vanderschoot, J; Zwinderman, A H; Dijkman, J H; Sterk, P J
1995-02-01
The association between lung sound alterations and airways obstruction has long been recognized in clinical practice, but the precise pathophysiological mechanisms of this relationship have not been determined. Therefore, we examined the changes in lung sounds at well-defined levels of methacholine-induced airway narrowing in eight normal and nine asthmatic subjects with normal baseline lung function. All subjects underwent phonopneumography at baseline condition and at > or = 20% fall in forced expiratory volume in one second (FEV1), and in asthmatic subjects also at > or = 40% fall in FEV1. Lung sounds were recorded at three locations on the chest wall during standardized quiet breathing, and during maximal forced breathing. Airflow-dependent power spectra were computed using fast Fourier transform. For each spectrum, we determined the intensity and frequency content of lung sounds, together with the extent of wheezing. The results were analysed using analysis of variance (ANOVA). During acute airway narrowing, the intensity and frequency content of the recorded sounds, as well as the extent of wheezing, were higher than at baseline in both groups of subjects. At similar levels of obstruction, both the pitch and the change in sound intensity with airflow were higher in asthmatics than in normal subjects. Wheezing, being nondiscriminative between the subject groups at baseline, was more prominent in asthmatics than in normal subjects at 20% fall in FEV1. We conclude that, at given levels of acute airway narrowing, lung sounds differ between asthmatics and normal subjects. This suggests that airflow-standardized phonopneumography is a sensitive method for detecting abnormalities in airway dynamics in asthma.(ABSTRACT TRUNCATED AT 250 WORDS)
The origin of Korotkoff sounds and the accuracy of auscultatory blood pressure measurements.
Babbs, Charles F
2015-12-01
This study explores the hypothesis that the sharper, high frequency Korotkoff sounds come from resonant motion of the arterial wall, which begins after the artery transitions from a buckled state to an expanding state. The motions of one mass, two nonlinear springs, and one damper, driven by transmural pressure under the cuff, are used to model and compute the Korotkoff sounds according to principles of classical Newtonian physics. The natural resonance of this spring-mass-damper system provides a concise, yet rigorous, explanation for the origin of Korotkoff sounds. Fundamentally, wall stretching in expansion requires more force than wall bending in buckling. At cuff pressures between systolic and diastolic arterial pressure, audible vibrations (> 40 Hz) occur during early expansion of the artery wall beyond its zero pressure radius after the outward moving mass of tissue experiences sudden deceleration, caused by the discontinuity in stiffness between bucked and expanded states. The idealized spring-mass-damper model faithfully reproduces the time-domain waveforms of actual Korotkoff sounds in humans. Appearance of arterial sounds occurs at or just above the level of systolic pressure. Disappearance of arterial sounds occurs at or just above the level of diastolic pressure. Muffling of the sounds is explained by increased resistance of the artery to collapse, caused by downstream venous engorgement. A simple analytical model can define the physical origin of Korotkoff sounds, suggesting improved mechanical or electronic filters for their selective detection and confirming the disappearance of the Korotkoff sounds as the optimal diastolic end point. Copyright © 2015 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Ovsiannikov, Mikhail; Ovsiannikov, Sergei
2017-01-01
The paper presents the combined approach to noise mapping and visualizing of industrial facilities sound pollution using forward ray tracing method and thin-plate spline interpolation. It is suggested to cauterize industrial area in separate zones with similar sound levels. Equivalent local source is defined for range computation of sanitary zones based on ray tracing algorithm. Computation of sound pressure levels within clustered zones are based on two-dimension spline interpolation of measured data on perimeter and inside the zone.
Madison, Guy
2014-03-01
Timing performance becomes less precise for longer intervals, which makes it difficult to achieve simultaneity in synchronisation with a rhythm. The metrical structure of music, characterised by hierarchical levels of binary or ternary subdivisions of time, may function to increase precision by providing additional timing information when the subdivisions are explicit. This hypothesis was tested by comparing synchronisation performance across different numbers of metrical levels conveyed by loudness of sounds, such that the slowest level was loudest and the fastest was softest. Fifteen participants moved their hand with one of 9 inter-beat intervals (IBIs) ranging from 524 to 3,125 ms in 4 metrical level (ML) conditions ranging from 1 (one movement for each sound) to 4 (one movement for every 8th sound). The lowest relative variability (SD/IBI<1.5%) was obtained for the 3 longest IBIs (1600-3,125 ms) and MLs 3-4, significantly less than the smallest value (4-5% at 524-1024 ms) for any ML 1 condition in which all sounds are identical. Asynchronies were also more negative with higher ML. In conclusion, metrical subdivision provides information that facilitates temporal performance, which suggests an underlying neural multi-level mechanism capable of integrating information across levels. © 2013.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-27
... Guidance for Assessing the Effects of Anthropogenic Sound on Marine Mammals--Acoustic Threshold Levels for.... SUMMARY: The National Marine Fisheries Service (NMFS) on behalf of NMFS and the National Ocean Service... availability of draft guidance for assessing the effects of anthropogenic sound on marine mammal species under...
Decibels via Loudness--Distance Properties of a Loudspeaker
ERIC Educational Resources Information Center
Bates, Alan
2014-01-01
Loudness, or sound intensity level, is a human perceived or subjective measurement with units, decibels, based on the response of the human ear to different sound intensities. The response of the human ear at fixed frequency is close to being logarithmic. The experiment reported here investigates the relationship between measured sound intensity…
Dynamic Assessment of Phonological Awareness for Children with Speech Sound Disorders
ERIC Educational Resources Information Center
Gillam, Sandra Laing; Ford, Mikenzi Bentley
2012-01-01
The current study was designed to examine the relationships between performance on a nonverbal phoneme deletion task administered in a dynamic assessment format with performance on measures of phoneme deletion, word-level reading, and speech sound production that required verbal responses for school-age children with speech sound disorders (SSDs).…
Sound Effects for Children's Comprehension of Variably-Paced Television Programs.
ERIC Educational Resources Information Center
Calvert, Sandra L.; Scott, M. Catherine
In this study, children's selective attention to, and comprehension of, variably-paced television programs were examined as a function of sound effects. Sixty-four children, equally distributed by sex and by preschool and fourth grades, were randomly assigned to one of four treatment conditions which crossed two levels of sound effects (presence…
Noise levels in neonatal intensive care unit and use of sound absorbing panel in the isolette.
Altuncu, E; Akman, I; Kulekci, S; Akdas, F; Bilgen, H; Ozek, E
2009-07-01
The purposes of this study were to measure the noise level of a busy neonatal intensive care unit (NICU) and to determine the effect of sound absorbing panel (SAP) on the level of noise inside the isolette. The sound pressure levels (SPL) of background noise, baby crying, alarms and closing of isolette's door/portholes were measured by a 2235-Brüel&Kjaer Sound Level Meter. Readings were repeated after applying SAP (3D pyramidal shaped open cell polyurethane foam) to the three lateral walls and ceiling of the isolette. The median SPL of background noise inside the NICU was 56dBA and it decreased to 47dBA inside the isolette. The median SPL of monitor alarms and baby crying inside the isolette were not different than SPL measured under radiant warmer (p>0.05). With SAP, the median SPL of temperature alarm inside the isolette decreased significantly from 82 to 72dBA, monitor alarm from 64 to 56dBA, porthole closing from 81 to 74dBA, and isolette door closing from 80 to 68dBA (p<0.01). There was a significant reduction in the noise produced by baby crying when SAP was used in the isolette (79dBA vs 69dBA, respectively) (p<0.0001). There was also significant attenuation effect of panel on the environmental noise. The noise level in our NICU is significantly above the universally recommended levels. Being inside the isolette protects infants from noise sources produced outside the isolette. However, very high noises are produced inside the isolette as well. Sound absorbing panel can be a simple solution and it attenuated the noise levels inside the isolette.
Structured Counseling for Auditory Dynamic Range Expansion.
Gold, Susan L; Formby, Craig
2017-02-01
A structured counseling protocol is described that, when combined with low-level broadband sound therapy from bilateral sound generators, offers audiologists a new tool for facilitating the expansion of the auditory dynamic range (DR) for loudness. The protocol and its content are specifically designed to address and treat problems that impact hearing-impaired persons who, due to their reduced DRs, may be limited in the use and benefit of amplified sound from hearing aids. The reduced DRs may result from elevated audiometric thresholds and/or reduced sound tolerance as documented by lower-than-normal loudness discomfort levels (LDLs). Accordingly, the counseling protocol is appropriate for challenging and difficult-to-fit persons with sensorineural hearing losses who experience loudness recruitment or hyperacusis. Positive treatment outcomes for individuals with the former and latter conditions are highlighted in this issue by incremental shifts (improvements) in LDL and/or categorical loudness judgments, associated reduced complaints of sound intolerance, and functional improvements in daily communication, speech understanding, and quality of life leading to improved hearing aid benefit, satisfaction, and aided sound quality, posttreatment.
Sound absorption of a porous material with a perforated facing at high sound pressure levels
NASA Astrophysics Data System (ADS)
Peng, Feng
2018-07-01
A semi-empirical model is proposed to predict the sound absorption of an acoustical unit consisting of a rigid-porous material layer with a perforated facing under the normal incidence at high sound pressure levels (SPLs) of pure tones. The nonlinearity of the perforated facing and the porous material, and the interference between them are considered in the model. The sound absorptive performance of the acoustical unit is tested at different incident SPLs and in three typical configurations: 1) when the perforated panel (PP) directly contacts with the porous layer, 2) when the PP is separated from the porous layer by an air gap and 3) when an air cavity is set between the porous material and the hard backing wall. The test results agree well with the corresponding theoretical predictions. Moreover, the results show that the interference effect is correlated to the width of the air gap between the PP and the porous layer, which alters not only the linear acoustic impedance but also the nonlinear acoustic impedance of the unit and hence its sound absorptive properties.
Fluid mechanical model of the Helmholtz resonator
NASA Technical Reports Server (NTRS)
Hersh, A. S.; Walker, B.
1977-01-01
A semi-empirical fluid mechanical model of the acoustic behavior of Helmholtz resonators is presented which predicts impedance as a function of the amplitude and frequency of the incident sound pressure field and resonator geometry. The model assumes that the particle velocity approaches the orifice in a spherical manner. The incident and cavity sound fields are connected by solving the governing oscillating mass and momentum conservation equations. The model is in agreement with the Rayleigh slug-mass model at low values of incident sound pressure level. At high values, resistance is predicted to be independent of frequency, proportional to the square root of the amplitude of the incident sound pressure field, and virtually independent of resonator geometry. Reactance is predicted to depend in a very complicated way upon resonator geometry, incident sound pressure level, and frequency. Nondimensional parameters are defined that divide resonator impedance into three categories corresponding to low, moderately low, and intense incident sound pressure amplitudes. The two-microphone method was used to measure the impedance of a variety of resonators. The data were used to refine and verify the model.
Structured Counseling for Auditory Dynamic Range Expansion
Gold, Susan L.; Formby, Craig
2017-01-01
A structured counseling protocol is described that, when combined with low-level broadband sound therapy from bilateral sound generators, offers audiologists a new tool for facilitating the expansion of the auditory dynamic range (DR) for loudness. The protocol and its content are specifically designed to address and treat problems that impact hearing-impaired persons who, due to their reduced DRs, may be limited in the use and benefit of amplified sound from hearing aids. The reduced DRs may result from elevated audiometric thresholds and/or reduced sound tolerance as documented by lower-than-normal loudness discomfort levels (LDLs). Accordingly, the counseling protocol is appropriate for challenging and difficult-to-fit persons with sensorineural hearing losses who experience loudness recruitment or hyperacusis. Positive treatment outcomes for individuals with the former and latter conditions are highlighted in this issue by incremental shifts (improvements) in LDL and/or categorical loudness judgments, associated reduced complaints of sound intolerance, and functional improvements in daily communication, speech understanding, and quality of life leading to improved hearing aid benefit, satisfaction, and aided sound quality, posttreatment. PMID:28286367
Tuning the cognitive environment: Sound masking with 'natural' sounds in open-plan offices
NASA Astrophysics Data System (ADS)
DeLoach, Alana
With the gain in popularity of open-plan office design and the engineering efforts to achieve acoustical comfort for building occupants, a majority of workers still report dissatisfaction in their workplace environment. Office acoustics influence organizational effectiveness, efficiency, and satisfaction through meeting appropriate requirements for speech privacy and ambient sound levels. Implementing a sound masking system is one tried-and-true method of achieving privacy goals. Although each sound masking system is tuned for its specific environment, the signal -- random steady state electronic noise, has remained the same for decades. This research work explores how `natural' sounds may be used as an alternative to this standard masking signal employed so ubiquitously in sound masking systems in the contemporary office environment. As an unobtrusive background sound, possessing the appropriate spectral characteristics, this proposed use of `natural' sounds for masking challenges the convention that masking sounds should be as meaningless as possible. Through the pilot study presented in this work, we hypothesize that `natural' sounds as sound maskers will be as effective at masking distracting background noise as the conventional masking sound, will enhance cognitive functioning, and increase participant (worker) satisfaction.
Brechmann, André; Baumgart, Frank; Scheich, Henning
2002-01-01
Recognition of sound patterns must be largely independent of level and of masking or jamming background sounds. Auditory patterns of relevance in numerous environmental sounds, species-specific vocalizations and speech are frequency modulations (FM). Level-dependent activation of the human auditory cortex (AC) in response to a large set of upward and downward FM tones was studied with low-noise (48 dB) functional magnetic resonance imaging at 3 Tesla. Separate analysis in four territories of AC was performed in each individual brain using a combination of anatomical landmarks and spatial activation criteria for their distinction. Activation of territory T1b (including primary AC) showed the most robust level dependence over the large range of 48-102 dB in terms of activated volume and blood oxygen level dependent contrast (BOLD) signal intensity. The left nonprimary territory T2 also showed a good correlation of level with activated volume but, in contrast to T1b, not with BOLD signal intensity. These findings are compatible with level coding mechanisms observed in animal AC. A systematic increase of activation with level was not observed for T1a (anterior of Heschl's gyrus) and T3 (on the planum temporale). Thus these areas might not be specifically involved in processing of the overall intensity of FM. The rostral territory T1a of the left hemisphere exhibited highest activation when the FM sound level fell 12 dB below scanner noise. This supports the previously suggested special involvement of this territory in foreground-background decomposition tasks. Overall, AC of the left hemisphere showed a stronger level-dependence of signal intensity and activated volume than the right hemisphere. But any side differences of signal intensity at given levels were lateralized to right AC. This might point to an involvement of the right hemisphere in more specific aspects of FM processing than level coding.
NASA Astrophysics Data System (ADS)
Homick, J. L.
1981-12-01
Using a hand-held sound pressure level meter the crew made one octave band and A-weight sound level measurements at four locations in the Orbiter on Mission Day 1. The data were voice recorded and transmitted to the ground prior to the first inflight sleep period. The data obtained are summarized. From a physiological point of view the noise levels measured on STS-1 were not hazardous to the crewmens' hearing.
NASA Astrophysics Data System (ADS)
Spence, Heather Ruth
Sound is the primary sensory modality for dolphins, yet policies mitigating anthropogenic sound exposure are limited in wild populations and even fewer noise policies or guidelines have been developed for governing dolphin welfare under human care. Concerns have been raised that dolphins under human care live in facilities that are too noisy, or are too acoustically sterile. However, these claims have not been evaluated to characterize facility soundscapes, and further, how they compare to wild soundscapes. The soundscape of a wild dolphin habitat off the coast of Quintana, Roo, Mexico was characterized based on Passive Acoustic Monitoring (PAM) recordings over one year. Snapping shrimp were persistent and broadband, following a diel pattern. Fish sound production was pulsed and prominent in low frequencies (100 -- 1000 Hz), and abiotic surface wave action contributed to noise in higher frequencies (15 -- 28 kHz). Boat motors were the main anthropogenic sound source. While sporadic, boat motors were responsible for large spikes in the noise, sometimes exceeding the ambient noise (in the absence of a boat) by 20 dB root-mean-squared sound pressure level, and potentially higher at closer distances. Boat motor sounds can potentially mask cues and communication sounds of dolphins. The soundscapes of four acoustically distinct outdoor dolphin facilities in Quintana Roo, Mexico were also characterized based on PAM, and findings compared with one another and with the measurements from the wild dolphin habitat. Recordings were made for at least 24 hours to encompass the range of daily activities. The four facilities differed in non-dolphin species present (biological sounds), bathymetry complexity, and method of water circulation. It was hypothesized that the greater the biological and physical differences of a pool from the ocean habitat, the greater the acoustic differences would be from the natural environment. Spectral analysis and audio playback revealed that the site most biologically and physically distinct from the ocean habitat also differed greatly from the other sites acoustically, with the most common and high amplitude sound being pump noise versus biological sounds at the other sites. Overall the dolphin facilities were neither clearly noisier nor more sterile than the wild site, but rather differed in particular characteristics. The findings are encouraging for dolphin welfare for several reasons. Sound levels measured were unlikely to cause threshold shifts in hearing. At three of four facilities, prominent biological sounds in the wild site -- snapping shrimp and fish sounds -- were present, meaning that the dolphins at these facilities are experiencing biotic features of the soundscape they would experience in the wild. Additionally, the main anthropogenic sounds experienced at the facilities (construction and cleaning sounds) did not reach the levels of the anthropogenic sounds experienced at the wild site (boat motor sounds), and the highest noise levels for anthropogenic sounds fall outside the dolphins' most sensitive range of hearing. However, there are anthropogenic contributors to the soundscape that are of particular interest and possible concern that should be investigated further, particularly pump noise and periodic or intermittent construction noise. These factors need to be considered on a facility-by-facility basis and appropriate mitigation procedures incorporated in animal handling to mitigate potential responses to planned or anticipated sound producing events, e.g. animal relocation or buffering sound producing activities. The central role of bioacoustics for dolphins means that PAM is a basic life support requirement along with water and food testing. Periodic noise is of highest concern, and PAM is needed to inform mitigation of noise from periodic sources. Priority actions are more widespread and long-term standardized monitoring, further research on habituation, preference, coupling and pool acoustics, implementation of acoustics training, standardization of measurements, and improved information access.
A methodology for estimating dog noise in an animal housing facility
NASA Technical Reports Server (NTRS)
Sierens, S. E.; Ingley, H. A.; Besch, E. L.
1977-01-01
A rectangular reverberation chamber was designed, constructed and calibrated for the experimental measurement of the sound power level (acoustic power) of a dog. Calibration of the chamber consisted of comparing the acoustic power measured for a random noise source in the chamber with that for the identical source in a free field environment. Data from dogs indicate that barking noise can be modeled as a square wave pattern with short duration and peak sound power levels in the 500 Hz octave band. A-weighted sound pressure levels of up to 114.7 dBA were absorbed, indicating a potential concern for both animals and man chronically exposed to such environments.
Optimization of programming parameters in children with the advanced bionics cochlear implant.
Baudhuin, Jacquelyn; Cadieux, Jamie; Firszt, Jill B; Reeder, Ruth M; Maxson, Jerrica L
2012-05-01
Cochlear implants provide access to soft intensity sounds and therefore improved audibility for children with severe-to-profound hearing loss. Speech processor programming parameters, such as threshold (or T-level), input dynamic range (IDR), and microphone sensitivity, contribute to the recipient's program and influence audibility. When soundfield thresholds obtained through the speech processor are elevated, programming parameters can be modified to improve soft sound detection. Adult recipients show improved detection for low-level sounds when T-levels are set at raised levels and show better speech understanding in quiet when wider IDRs are used. Little is known about the effects of parameter settings on detection and speech recognition in children using today's cochlear implant technology. The overall study aim was to assess optimal T-level, IDR, and sensitivity settings in pediatric recipients of the Advanced Bionics cochlear implant. Two experiments were conducted. Experiment 1 examined the effects of two T-level settings on soundfield thresholds and detection of the Ling 6 sounds. One program set T-levels at 10% of most comfortable levels (M-levels) and another at 10 current units (CUs) below the level judged as "soft." Experiment 2 examined the effects of IDR and sensitivity settings on speech recognition in quiet and noise. Participants were 11 children 7-17 yr of age (mean 11.3) implanted with the Advanced Bionics High Resolution 90K or CII cochlear implant system who had speech recognition scores of 20% or greater on a monosyllabic word test. Two T-level programs were compared for detection of the Ling sounds and frequency modulated (FM) tones. Differing IDR/sensitivity programs (50/0, 50/10, 70/0, 70/10) were compared using Ling and FM tone detection thresholds, CNC (consonant-vowel nucleus-consonant) words at 50 dB SPL, and Hearing in Noise Test for Children (HINT-C) sentences at 65 dB SPL in the presence of four-talker babble (+8 signal-to-noise ratio). Outcomes were analyzed using a paired t-test and a mixed-model repeated measures analysis of variance (ANOVA). T-levels set 10 CUs below "soft" resulted in significantly lower detection thresholds for all six Ling sounds and FM tones at 250, 1000, 3000, 4000, and 6000 Hz. When comparing programs differing by IDR and sensitivity, a 50 dB IDR with a 0 sensitivity setting showed significantly poorer thresholds for low frequency FM tones and voiced Ling sounds. Analysis of group mean scores for CNC words in quiet or HINT-C sentences in noise indicated no significant differences across IDR/sensitivity settings. Individual data, however, showed significant differences between IDR/sensitivity programs in noise; the optimal program differed across participants. In pediatric recipients of the Advanced Bionics cochlear implant device, manually setting T-levels with ascending loudness judgments should be considered when possible or when low-level sounds are inaudible. Study findings confirm the need to determine program settings on an individual basis as well as the importance of speech recognition verification measures in both quiet and noise. Clinical guidelines are suggested for selection of programming parameters in both young and older children. American Academy of Audiology.
Bao, Shaowen; Chang, Edward F.; Teng, Ching-Ling; Heiser, Marc A.; Merzenich, Michael M.
2013-01-01
Cortical sensory representations can be reorganized by sensory exposure in an epoch of early development. The adaptive role of this type of plasticity for natural sounds in sensory development is, however, unclear. We have reared rats in a naturalistic, complex acoustic environment and examined their auditory representations. We found that cortical neurons became more selective to spectrotemporal features in the experienced sounds. At the neuronal population level, more neurons were involved in representing the whole set of complex sounds, but fewer neurons actually responded to each individual sound, but with greater magnitudes. A comparison of population-temporal responses to the experienced complex sounds revealed that cortical responses to different renderings of the same song motif were more similar, indicating that the cortical neurons became less sensitive to natural acoustic variations associated with stimulus context and sound renderings. By contrast, cortical responses to sounds of different motifs became more distinctive, suggesting that cortical neurons were tuned to the defining features of the experienced sounds. These effects lead to emergent “categorical” representations of the experienced sounds, which presumably facilitate their recognition. PMID:23747304
Development of sound measurement systems for auditory functional magnetic resonance imaging.
Nam, Eui-Cheol; Kim, Sam Soo; Lee, Kang Uk; Kim, Sang Sik
2008-06-01
Auditory functional magnetic resonance imaging (fMRI) requires quantification of sound stimuli in the magnetic environment and adequate isolation of background noise. We report the development of two novel sound measurement systems that accurately measure the sound intensity inside the ear, which can simultaneously provide the similar or greater amount of scanner- noise protection than ear-muffs. First, we placed a 2.6 x 2.6-mm microphone in an insert phone that was connected to a headphone [microphone-integrated, foam-tipped insert-phone with a headphone (MIHP)]. This attenuated scanner noise by 37.8+/-4.6 dB, a level better than the reference amount obtained using earmuffs. The nonmetallic optical microphone was integrated with a headphone [optical microphone in a headphone (OMHP)] and it effectively detected the change of sound intensity caused by variable compression on the cushions of the headphone. Wearing the OMHP reduced the noise by 28.5+/-5.9 dB and did not affect echoplanar magnetic resonance images. We also performed an auditory fMRI study using the MIHP system and presented increase in the auditory cortical activation following 10-dB increment in the intensity of sound stimulation. These two newly developed sound measurement systems successfully achieved the accurate quantification of sound stimuli with maintaining the similar level of noise protection of wearing earmuffs in the auditory fMRI experiment.
Warszawa, Anna; Sataloff, Robert T
2010-09-01
The harmful effects of noise exposure during leisure-time activities are beginning to receive some scrutiny. We conducted a preliminary study to investigate the noise levels during the showings of 25 different films. During each screening, various sound measurements were made with a dosimeter. The movies were classified on the basis of both their Motion Picture Association of America (MPAA) rating and their genre, and the size of the theater and the size of the audience were taken into consideration in the final analysis. Our findings suggest that the sound levels of many movies might be harmful to hearing, although we can draw no definitive conclusions. We did not discern any relationship between noise levels and either MPAA rating or genre. Further studies are recommended.
NASA Technical Reports Server (NTRS)
Embleton, Tony F. W.; Daigle, Gilles A.
1991-01-01
Reviewed here is the current state of knowledge with respect to each basic mechanism of sound propagation in the atmosphere and how each mechanism changes the spectral or temporal characteristics of the sound received at a distance from the source. Some of the basic processes affecting sound wave propagation which are present in any situation are discussed. They are geometrical spreading, molecular absorption, and turbulent scattering. In geometrical spreading, sound levels decrease with increasing distance from the source; there is no frequency dependence. In molecular absorption, sound energy is converted into heat as the sound wave propagates through the air; there is a strong dependence on frequency. In turbulent scattering, local variations in wind velocity and temperature induce fluctuations in phase and amplitude of the sound waves as they propagate through an inhomogeneous medium; there is a moderate dependence on frequency.
Ambient Noise in Emergency Rooms and Its Health Hazards
Filus, Walderes; Lacerda, Adriana Bender Moreira de; Albizu, Evelyn
2014-01-01
Introduction The occupational risk due to high levels of noise in the hospital environment has been recognized, and the National Agency of Sanitary Surveillance of the Ministry of Health recommends evaluation and control of noise in hospital areas. Objectives To assess the sound environment in the emergency ward of a general trauma reference hospital in the city of Curitiba, Parana State, Brazil. Methods In this descriptive study, noise levels were assessed on mornings, afternoons, and evenings using an integrating Bruel & Kjaer (Denmark) calibrated sound level meter, type 2230. Ten indoor points in the emergency ward were assessed; the helicopter as well as several available pieces of equipment in the ward were assessed individually. Results Noise levels in sound pressure level ambiance [dBA] ranged from 56.6 to 68.8. The afternoon period was the noisiest. The helicopter at 119 dBA and the cast saw at 90 dBA were the noisiest equipment, and the lowest noise level found was the activated oximeter at 61.0 dBA. Conclusion In all assessed points, noise levels were above the comfort levels recommended by the Brazilian Association of Technical Standards (1987), which may harm users' and professionals' health as well as influence professional performance in the emergency ward. Sound pressure levels of the helicopter and cast saw reach high hearing hazard levels, requiring professionals to use individual protection equipment, and point to the need for creation and implementation of effective control measures of noise levels in emergency wards. PMID:26157493
Zhang, Bin; Song, Wen-Ai; Wei, Yue-Juan; Zhang, Dong-Song; Liu, Wen-Yi
2017-06-15
By simulating the sound field of a round piston transducer with the Kirchhoff integral theorem and analyzing the shape of ultrasound beams and propagation characteristics in a metal container wall, this study presents a model for calculating the echo sound pressure by using the Kirchhoff paraxial approximation theory, based on which and according to different ultrasonic impedance between gas and liquid media, a method for detecting the liquid level from outside of sealed containers is proposed. Then, the proposed method is evaluated through two groups of experiments. In the first group, three kinds of liquid media with different ultrasonic impedance are used as detected objects; the echo sound pressure is calculated by using the proposed model under conditions of four sets of different wall thicknesses. The changing characteristics of the echo sound pressure in the entire detection process are analyzed, and the effects of different ultrasonic impedance of liquids on the echo sound pressure are compared. In the second group, taking water as an example, two transducers with different radii are selected to measure the liquid level under four sets of wall thickness. Combining with sound field characteristics, the influence of different size transducers on the pressure calculation and detection resolution are discussed and analyzed. Finally, the experimental results indicate that measurement uncertainly is better than ±5 mm, which meets the industrial inspection requirements.
Zhang, Bin; Song, Wen-Ai; Wei, Yue-Juan; Zhang, Dong-Song; Liu, Wen-Yi
2017-01-01
By simulating the sound field of a round piston transducer with the Kirchhoff integral theorem and analyzing the shape of ultrasound beams and propagation characteristics in a metal container wall, this study presents a model for calculating the echo sound pressure by using the Kirchhoff paraxial approximation theory, based on which and according to different ultrasonic impedance between gas and liquid media, a method for detecting the liquid level from outside of sealed containers is proposed. Then, the proposed method is evaluated through two groups of experiments. In the first group, three kinds of liquid media with different ultrasonic impedance are used as detected objects; the echo sound pressure is calculated by using the proposed model under conditions of four sets of different wall thicknesses. The changing characteristics of the echo sound pressure in the entire detection process are analyzed, and the effects of different ultrasonic impedance of liquids on the echo sound pressure are compared. In the second group, taking water as an example, two transducers with different radii are selected to measure the liquid level under four sets of wall thickness. Combining with sound field characteristics, the influence of different size transducers on the pressure calculation and detection resolution are discussed and analyzed. Finally, the experimental results indicate that measurement uncertainly is better than ±5 mm, which meets the industrial inspection requirements. PMID:28617326
Mercadíe, Lolita; Mick, Gérard; Guétin, Stéphane; Bigand, Emmanuel
2015-10-01
In fibromyalgia, pain symptoms such as hyperalgesia and allodynia are associated with fatigue. Mechanisms underlying such symptoms can be modulated by listening to pleasant music. We expected that listening to music, because of its emotional impact, would have a greater modulating effect on the perception of pain and fatigue in patients with fibromyalgia than listening to nonmusical sounds. To investigate this hypothesis, we carried out a 4-week study in which patients with fibromyalgia listened to either preselected musical pieces or environmental sounds when they experienced pain in active (while carrying out a physical activity) or passive (at rest) situations. Concomitant changes of pain and fatigue levels were evaluated. When patients listened to music or environmental sounds at rest, pain and fatigue levels were significantly reduced after 20 minutes of listening, with no difference of effect magnitude between the two stimuli. This improvement persisted 10 minutes after the end of the listening session. In active situations, pain did not increase in presence of the two stimuli. Contrary to our expectations, music and environmental sounds produced a similar relieving effect on pain and fatigue, with no benefit gained by listening to pleasant music over environmental sounds. Copyright © 2015 American Society for Pain Management Nursing. Published by Elsevier Inc. All rights reserved.
40 CFR 205.54-2 - Sound data acquisition system.
Code of Federal Regulations, 2012 CFR
2012-07-01
... of 86 dB (rms) and the level indicated for an octave band of random noise of equal energy as the... Publication 179, Precision Sound Level Meters. (v) Magnetic tape recorders. No requirements are described in...) Calibrate tape recorders using the brand and type of magnetic tape used for actual data acquisition...
49 CFR 325.57 - Location and operation of sound level measurement systems; stationary test.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 5 2014-10-01 2014-10-01 false Location and operation of sound level measurement systems; stationary test. 325.57 Section 325.57 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION GENERAL REGULATIONS COMPLIANCE WITH INTERSTATE MOTOR...
Surface data - sea 2 Vertical soundings (other than satellite) 3 Vertical soundings (satellite) 4 Single level upper-air data (other than satellite) 5 Single level upper-air data (satellite) 6 Radar data 7 tables, complete replacement or update 12 Surface data (satellite) 13 Forecasts 14 Warnings 15-19
49 CFR 325.57 - Location and operation of sound level measurement systems; stationary test.
Code of Federal Regulations, 2010 CFR
2010-10-01
... the vehicle at an angle that is consistent with the recommendation of the system's manufacturer. If... systems; stationary test. 325.57 Section 325.57 Transportation Other Regulations Relating to...; Stationary Test § 325.57 Location and operation of sound level measurement systems; stationary test. (a) The...
49 CFR 325.37 - Location and operation of sound level measurement system; highway operations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... recommendation of the manufacturer of the sound level measurement system. (2) In no case shall the holder or... angle that is consistent with the recommendation of the system's manufacturer. If the manufacturer of... system; highway operations. 325.37 Section 325.37 Transportation Other Regulations Relating to...
46 CFR 56.50-90 - Sounding devices.
Code of Federal Regulations, 2010 CFR
2010-10-01
... fuel-oil tank may terminate in any space where the risk of ignition of spillage from the pipe might... following requirements are met: (1) In addition to the sounding pipe, the fuel-oil tank has an oil-level... of oil-level gauges with flat glasses and self-closing valves between the gauges and fuel tanks is...
The effect of exposure duration on the subjective discomfort of aircraft cabin noise.
Huang, Yu; Jiang, Weikang
2017-01-01
The time dependency for subjective responses to noise has been a controversial question over many years. For durations of up to 10 min, the discomfort produced by three levels of noise (ie 60, 70 and 80 dBA) was investigated in this experimental study to determine the relation of discomfort to the time duration of noise. The rate of increase in discomfort with increasing duration was 1.5 dB per doubling of exposure duration, whereas it is currently assumed to be 3 dB per doubling of exposure duration. The sound dose level (SDL) was proposed to predict the discomfort caused by noise of long duration. The combination of SDL and vibration dose value (VDV) provided more consistent estimates of the equivalent comfort contours between noise and vibration over durations from 2 to 32 s than the combination of sound exposure level and VDV or that of sound pressure level and r.m.s. acceleration. Practitioner Summary: The discomfort produced by noise of long duration can be well predicted from a new definition of sound dose level, where the discomfort increases at 1.5 dB per doubling of exposure duration.
49 CFR 325.9 - Measurement tolerances.
Code of Federal Regulations, 2011 CFR
2011-10-01
... reporting filed sound level measurements to the nearest whole decibel. (2) Variations resulting from... atmospheric pressure. (5) Variations resulting from reflected sound from small objects allowed within the test...
Modeling the utility of binaural cues for underwater sound localization.
Schneider, Jennifer N; Lloyd, David R; Banks, Patchouly N; Mercado, Eduardo
2014-06-01
The binaural cues used by terrestrial animals for sound localization in azimuth may not always suffice for accurate sound localization underwater. The purpose of this research was to examine the theoretical limits of interaural timing and level differences available underwater using computational and physical models. A paired-hydrophone system was used to record sounds transmitted underwater and recordings were analyzed using neural networks calibrated to reflect the auditory capabilities of terrestrial mammals. Estimates of source direction based on temporal differences were most accurate for frequencies between 0.5 and 1.75 kHz, with greater resolution toward the midline (2°), and lower resolution toward the periphery (9°). Level cues also changed systematically with source azimuth, even at lower frequencies than expected from theoretical calculations, suggesting that binaural mechanical coupling (e.g., through bone conduction) might, in principle, facilitate underwater sound localization. Overall, the relatively limited ability of the model to estimate source position using temporal and level difference cues underwater suggests that animals such as whales may use additional cues to accurately localize conspecifics and predators at long distances. Copyright © 2014 Elsevier B.V. All rights reserved.
Kastelein, Ronald A; Helder-Hoek, Lean; Van de Voorde, Shirley
2017-10-01
Safety criteria for naval sonar sounds are needed to protect harbor porpoise hearing. Two porpoises were exposed to sequences of AN/SQS-53C sonar playback sounds (3.5-4.1 kHz, without significant harmonics), at a mean received sound pressure level of 142 dB re 1 μPa, with a duty cycle of 96% (almost continuous). Behavioral hearing thresholds at 4 and 5.7 kHz were determined before and after exposure to the fatiguing sound, in order to quantify temporary threshold shifts (TTSs) and hearing recovery. Control sessions were also conducted. Significant mean initial TTS 1-4 of 5.2 dB at 4 kHz and 3.1 dB at 5.7 kHz occurred after 30 min exposures (mean received cumulative sound exposure level, SEL cum : 175 dB re 1 μPa 2 s). Hearing thresholds returned to pre-exposure levels within 12 min. Significant mean initial TTS 1-4 of 5.5 dB at 4 kHz occurred after 60 min exposures (SEL cum : 178 dB re 1 μPa 2 s). Hearing recovered within 60 min. The SEL cum for AN/SQS-53C sonar sounds required to induce 6 dB of TTS 4 min after exposure (the definition of TTS onset) is expected to be between 175 and 180 dB re 1 μPa 2 s.
Semicircular Canal Pressure Changes During High-intensity Acoustic Stimulation.
Maxwell, Anne K; Banakis Hartl, Renee M; Greene, Nathaniel T; Benichoux, Victor; Mattingly, Jameson K; Cass, Stephen P; Tollin, Daniel J
2017-08-01
Acoustic stimulation generates measurable sound pressure levels in the semicircular canals. High-intensity acoustic stimuli can cause hearing loss and balance disruptions. To examine the propagation of acoustic stimuli to the vestibular end-organs, we simultaneously measured fluid pressure in the cochlea and semicircular canals during both air- and bone-conducted sound presentation. Five full-cephalic human cadaveric heads were prepared bilaterally with a mastoidectomy and extended facial recess. Vestibular pressures were measured within the superior, lateral, and posterior semicircular canals, and referenced to intracochlear pressure within the scala vestibuli with fiber-optic pressure probes. Pressures were measured concurrently with laser Doppler vibrometry measurements of stapes velocity during stimulation with both air- and bone-conduction. Stimuli were pure tones between 100 Hz and 14 kHz presented with custom closed-field loudspeakers for air-conducted sounds and via commercially available bone-anchored device for bone-conducted sounds. Pressures recorded in the superior, lateral, and posterior semicircular canals in response to sound stimulation were equal to or greater in magnitude than those recorded in the scala vestibuli (up to 20 dB higher). The pressure magnitudes varied across canals in a frequency-dependent manner. High sound pressure levels were recorded in the semicircular canals with sound stimulation, suggesting that similar acoustical energy is transmitted to the semicircular canals and the cochlea. Since these intralabyrinthine pressures exceed intracochlear pressure levels, our results suggest that the vestibular end-organs may also be at risk for injury during exposure to high-intensity acoustic stimuli known to cause trauma in the auditory system.
The influence of company identity on the perception of vehicle sounds.
Humphreys, Louise; Giudice, Sebastiano; Jennings, Paul; Cain, Rebecca; Song, Wookeun; Dunne, Garry
2011-04-01
In order to determine how the interior of a car should sound, automotive manufacturers often rely on obtaining data from individual evaluations of vehicle sounds. Company identity could play a role in these appraisals, particularly when individuals are comparing cars from opposite ends of the performance spectrum. This research addressed the question: does company identity influence the evaluation of automotive sounds belonging to cars of a similar performance level and from the same market segment? Participants listened to car sounds from two competing manufacturers, together with control sounds. Before listening to each sound, participants were presented with the correct company identity for that sound, the incorrect identity or were given no information about the identity of the sound. The results showed that company identity did not influence appraisals of high performance cars belonging to different manufacturers. These results have positive implications for methodologies employed to capture the perceptions of individuals. STATEMENT OF RELEVANCE: A challenge in automotive design is to set appropriate targets for vehicle sounds, relying on understanding subjective reactions of individuals to such sounds. This paper assesses the role of company identity in influencing these subjective reactions and will guide sound evaluation studies, in which the manufacturer is often apparent.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-21
... located inside Port Townsend Bay in northern Puget Sound (see Figure 1- 9 in the WSF IHA application..., and 2 cylinder shaft casings). Because elevated sound levels from pile driving have the potential to... hydraulic lift span at the Port Townsend ferry terminal in northern Puget Sound, Washington. Transfer spans...
What is a melody? On the relationship between pitch and brightness of timbre
Cousineau, Marion; Carcagno, Samuele; Demany, Laurent; Pressnitzer, Daniel
2014-01-01
Previous studies showed that the perceptual processing of sound sequences is more efficient when the sounds vary in pitch than when they vary in loudness. We show here that sequences of sounds varying in brightness of timbre are processed with the same efficiency as pitch sequences. The sounds used consisted of two simultaneous pure tones one octave apart, and the listeners’ task was to make same/different judgments on pairs of sequences varying in length (one, two, or four sounds). In one condition, brightness of timbre was varied within the sequences by changing the relative level of the two pure tones. In other conditions, pitch was varied by changing fundamental frequency, or loudness was varied by changing the overall level. In all conditions, only two possible sounds could be used in a given sequence, and these two sounds were equally discriminable. When sequence length increased from one to four, discrimination performance decreased substantially for loudness sequences, but to a smaller extent for brightness sequences and pitch sequences. In the latter two conditions, sequence length had a similar effect on performance. These results suggest that the processes dedicated to pitch and brightness analysis, when probed with a sequence-discrimination task, share unexpected similarities. PMID:24478638
Nachtigall, Paul E; Supin, Alexander Ya; Estaban, Jose-Antonio; Pacini, Aude F
2016-02-01
Ice-dwelling beluga whales are increasingly being exposed to anthropogenic loud sounds. Beluga's hearing sensitivity measured during a warning sound just preceding a loud sound was tested using pip-train stimuli and auditory evoked potential recording. When the test/warning stimulus with a frequency of 32 or 45 kHz preceded the loud sound with a frequency of 32 kHz and a sound pressure level of 153 dB re 1 μPa, 2 s, hearing thresholds before the loud sound increased relative to the baseline. The threshold increased up to 15 dB for the test frequency of 45 kHz and up to 13 dB for the test frequency of 32 kHz. These threshold increases were observed during two sessions of 36 trials each. Extinction tests revealed no change during three experimental sessions followed by a jump-like return to baseline thresholds. The low exposure level producing the hearing-dampening effect (156 dB re 1 µPa(2)s in each trial), and the manner of extinction, may be considered as evidence that the observed hearing threshold increases were a demonstration of conditioned dampening of hearing when the whale anticipated the quick appearance of a loud sound in the same way demonstrated in the false killer whale and bottlenose dolphin.
Bottom-up approach for microstructure optimization of sound absorbing materials.
Perrot, Camille; Chevillotte, Fabien; Panneton, Raymond
2008-08-01
Results from a numerical study examining micro-/macrorelations linking local geometry parameters to sound absorption properties are presented. For a hexagonal structure of solid fibers, the porosity phi, the thermal characteristic length Lambda('), the static viscous permeability k(0), the tortuosity alpha(infinity), the viscous characteristic length Lambda, and the sound absorption coefficient are computed. Numerical solutions of the steady Stokes and electrical equations are employed to provide k(0), alpha(infinity), and Lambda. Hybrid estimates based on direct numerical evaluation of phi, Lambda('), k(0), alpha(infinity), Lambda, and the analytical model derived by Johnson, Allard, and Champoux are used to relate varying (i) throat size, (ii) pore size, and (iii) fibers' cross-section shapes to the sound absorption spectrum. The result of this paper tends to demonstrate the important effect of throat size in the sound absorption level, cell size in the sound absorption frequency selectivity, and fibers' cross-section shape in the porous material weight reduction. In a hexagonal porous structure with solid fibers, the sound absorption level will tend to be maximized with a 48+/-10 microm throat size corresponding to an intermediate resistivity, a 13+/-8 microm fiber radius associated with relatively small interfiber distances, and convex triangular cross-section shape fibers allowing weight reduction.
Caldwell, Michael S.; Bee, Mark A.
2014-01-01
The ability to reliably locate sound sources is critical to anurans, which navigate acoustically complex breeding choruses when choosing mates. Yet, the factors influencing sound localization performance in frogs remain largely unexplored. We applied two complementary methodologies, open and closed loop playback trials, to identify influences on localization abilities in Cope’s gray treefrog, Hyla chrysoscelis. We examined localization acuity and phonotaxis behavior of females in response to advertisement calls presented from 12 azimuthal angles, at two signal levels, in the presence and absence of noise, and at two noise levels. Orientation responses were consistent with precise localization of sound sources, rather than binary discrimination between sources on either side of the body (lateralization). Frogs were unable to discriminate between sounds arriving from forward and rearward directions, and accurate localization was limited to forward sound presentation angles. Within this region, sound presentation angle had little effect on localization acuity. The presence of noise and low signal-to-noise ratios also did not strongly impair localization ability in open loop trials, but females exhibited reduced phonotaxis performance consistent with impaired localization during closed loop trials. We discuss these results in light of previous work on spatial hearing in anurans. PMID:24504182
Schoppe, Oliver; King, Andrew J.; Schnupp, Jan W.H.; Harper, Nicol S.
2016-01-01
Adaptation to stimulus statistics, such as the mean level and contrast of recently heard sounds, has been demonstrated at various levels of the auditory pathway. It allows the nervous system to operate over the wide range of intensities and contrasts found in the natural world. Yet current standard models of the response properties of auditory neurons do not incorporate such adaptation. Here we present a model of neural responses in the ferret auditory cortex (the IC Adaptation model), which takes into account adaptation to mean sound level at a lower level of processing: the inferior colliculus (IC). The model performs high-pass filtering with frequency-dependent time constants on the sound spectrogram, followed by half-wave rectification, and passes the output to a standard linear–nonlinear (LN) model. We find that the IC Adaptation model consistently predicts cortical responses better than the standard LN model for a range of synthetic and natural stimuli. The IC Adaptation model introduces no extra free parameters, so it improves predictions without sacrificing parsimony. Furthermore, the time constants of adaptation in the IC appear to be matched to the statistics of natural sounds, suggesting that neurons in the auditory midbrain predict the mean level of future sounds and adapt their responses appropriately. SIGNIFICANCE STATEMENT An ability to accurately predict how sensory neurons respond to novel stimuli is critical if we are to fully characterize their response properties. Attempts to model these responses have had a distinguished history, but it has proven difficult to improve their predictive power significantly beyond that of simple, mostly linear receptive field models. Here we show that auditory cortex receptive field models benefit from a nonlinear preprocessing stage that replicates known adaptation properties of the auditory midbrain. This improves their predictive power across a wide range of stimuli but keeps model complexity low as it introduces no new free parameters. Incorporating the adaptive coding properties of neurons will likely improve receptive field models in other sensory modalities too. PMID:26758822
... Sound therapies that involve simple things like background music or noise or specialized ear level maskers may ... exposure to high intensity sounds, specifically listening to music. In particular, virtually all teenagers use personal MP3 ...
Long term estimations of low frequency noise levels over water from an off-shore wind farm.
Bolin, Karl; Almgren, Martin; Ohlsson, Esbjörn; Karasalo, Ilkka
2014-03-01
This article focuses on computations of low frequency sound propagation from an off-shore wind farm. Two different methods for sound propagation calculations are combined with meteorological data for every 3 hours in the year 2010 to examine the varying noise levels at a reception point at 13 km distance. It is shown that sound propagation conditions play a vital role in the noise impact from the off-shore wind farm and ordinary assessment methods can become inaccurate at longer propagation distances over water. Therefore, this paper suggests that methodologies to calculate noise immission with realistic sound speed profiles need to be combined with meteorological data over extended time periods to evaluate the impact of low frequency noise from modern off-shore wind farms.
A Sound Pressure-level Meter Without Amplification
NASA Technical Reports Server (NTRS)
Stowell, E Z
1937-01-01
The N.A.C.A. has developed a simple pressure-level meter for the measurement of sound-pressure levels above 70 db. The instrument employs a carbon microphone but has no amplification. The source of power is five flashlight batteries. Measurements may be made up to the threshold of feeling with an accuracy of plus or minus 2 db; band analysis of complex spectra may be made if desired.
Teaching letter sounds to kindergarten English language learners using incremental rehearsal.
Peterson, Meredith; Brandes, Dana; Kunkel, Amy; Wilson, Jennifer; Rahn, Naomi L; Egan, Andrea; McComas, Jennifer
2014-02-01
Proficiency in letter-sound correspondence is important for decoding connected text. This study examined the effects of an evidence-based intervention, incremental rehearsal (IR), on the letter-sound expression of three kindergarten English language learners (ELLs) performing below the district benchmark for letter-sound fluency. Participants were native speakers of Hmong, Spanish, and Polish. A multiple-baseline design across sets of unknown letter sounds was used to evaluate the effects of IR on letter-sound expression. Visual analysis of the data showed an increase in level and trend when IR was introduced in each phase. Percentage of all non-overlapping data (PAND) ranged from 95% to 100%. All participants exceeded expected growth and reached the spring district benchmark for letter-sound fluency. Results suggest that IR is a promising intervention for increasing letter-sound expression for ELLs who evidence delays in acquiring letter sounds. Copyright © 2013 Society for the Study of School Psychology. Published by Elsevier Ltd. All rights reserved.
Evidence for distinct human auditory cortex regions for sound location versus identity processing
Ahveninen, Jyrki; Huang, Samantha; Nummenmaa, Aapo; Belliveau, John W.; Hung, An-Yi; Jääskeläinen, Iiro P.; Rauschecker, Josef P.; Rossi, Stephanie; Tiitinen, Hannu; Raij, Tommi
2014-01-01
Neurophysiological animal models suggest that anterior auditory cortex (AC) areas process sound-identity information, whereas posterior ACs specialize in sound location processing. In humans, inconsistent neuroimaging results and insufficient causal evidence have challenged the existence of such parallel AC organization. Here we transiently inhibit bilateral anterior or posterior AC areas using MRI-guided paired-pulse transcranial magnetic stimulation (TMS) while subjects listen to Reference/Probe sound pairs and perform either sound location or identity discrimination tasks. The targeting of TMS pulses, delivered 55–145 ms after Probes, is confirmed with individual-level cortical electric-field estimates. Our data show that TMS to posterior AC regions delays reaction times (RT) significantly more during sound location than identity discrimination, whereas TMS to anterior AC regions delays RTs significantly more during sound identity than location discrimination. This double dissociation provides direct causal support for parallel processing of sound identity features in anterior AC and sound location in posterior AC. PMID:24121634
NASA Astrophysics Data System (ADS)
Abbasi, Milad; Monnazzam, Mohammad Reza; Zakerian, Sayedabbolfazl; Yousefzadeh, Arsalan
2015-04-01
Noise from wind turbines is one of the most important factors affecting the health, welfare, and human sleep. This research was carried out to study the effect of wind turbine noise on workers' sleep disorder. For this, Manjil Wind Farm, because of the greater number of staff and turbines than other wind farms in Iran, was chosen as case study. A total number of 53 participants took part in this survey. They were classified into three groups of mechanics, security, and official. In this study, daytime sleepiness data of workers were gathered using Epworth Sleepiness Scales (ESS) was used to determine the level of daytime sleepiness among the workers. The 8-h equivalent sound level (LAeq,8h) was measured to determine the individuals' exposure at each occupational group. Finally, the effect of sound, age, and workers' experience on individuals' sleep disorder was analyzed through multiple regression analysis in the R software. The results showed that there was a positive and significant relationship between age, workers' experience, equivalent sound level, and the level of sleep disorder. When age is constant, sleep disorder will increase by 26% as per each 1 dB increase in equivalent sound level. In situations where equivalent sound level is constant, an increase of 17% in sleep disorder is occurred as per each year of work experience. Because of the difference in sound exposure in different occupational groups. The effect of noise in repairing group was about 6.5 times of official group and also 3.4 times of the security group. Sleep disorder effect caused by wind turbine noise in the security group is almost two times more than the official group. Unlike most studies on wind turbine noise that address the sleep disorder among inhabitants nearby wind farms, this study, for the first time in the world, examines the impact of wind turbine noise on sleep disorder of workers who are more closer to wind turbines and exposed to higher levels of noise. So despite all the good benefits of wind turbines, it can be stated that this technology has health risks for all those exposed to its sound. However, further research is needed to confirm the results of this study.
Feasibility of making sound power measurements in the NASA Langley V/STOL tunnel test section
NASA Technical Reports Server (NTRS)
Brooks, T. F.; Scheiman, J.; Silcox, R. J.
1976-01-01
Based on exploratory acoustic measurements in Langley's V/STOL wind tunnel, recommendations are made on the methodology for making sound power measurements of aircraft components in the closed tunnel test section. During airflow, tunnel self-noise and microphone flow-induced noise place restrictions on the amplitude and spectrum of the sound source to be measured. Models of aircraft components with high sound level sources, such as thrust engines and powered lift systems, seem likely candidates for acoustic testing.
Study of design constraints on helicopter noise
NASA Technical Reports Server (NTRS)
Sternfeld, H., Jr.; Wiedersum, C. W.
1979-01-01
A means of estimating the noise generated by a helicopter main rotor using information which is generally available during the preliminary design phase of aircraft development is presented. The method utilizes design charts and tables which do not require an understanding of acoustical theory or computational procedures in order to predict the perceived noise level, a weighted sound pressure level, or C weighted sound pressure level of a single hovering rotor. A method for estimating the effective perceived noise level in forward flight is also included. In order to give the designer an assessment of the relative rotor performance, which may be traded off against noise, an additional chart for estimating the percent of available rotor thrust which must be expended in lifting the rotor and drive system, is included as well as approach for comparing the subjective acceptability of various rotors once the absolute sound pressure levels are predicted.
Annoyance caused by the sounds of a magnetic levitation train
NASA Astrophysics Data System (ADS)
Vos, Joos
2004-04-01
In a laboratory study, the annoyance caused by the passby sounds from a magnetic levitation (maglev) train was investigated. The listeners were presented with various sound fragments. The task of the listeners was to respond after each presentation to the question: ``How annoying would you find the sound in the preceding period if you were exposed to it at home on a regular basis?'' The independent variables were (a) the driving speed of the maglev train (varying from 100 to 400 km/h), (b) the outdoor A-weighted sound exposure level (ASEL) of the passbys (varying from 65 to 90 dB), and (c) the simulated outdoor-to-indoor reduction in sound level (windows open or windows closed). As references to the passby sounds from the maglev train (type Transrapid 08), sounds from road traffic (passenger cars and trucks) and more conventional railway (intercity trains) were included for rating also. Four important results were obtained. Provided that the outdoor ASELs were the same, (1) the annoyance was independent of the driving speed of the maglev train, (2) the annoyance caused by the maglev train was considerably higher than that caused by the intercity train, (3) the annoyance caused by the maglev train was hardly different from that caused by road traffic, and (4) the results (1)-(3) held true both for open or closed windows. On the basis of the present results, it might be expected that the sounds are equally annoying if the ASELs of the maglev-train passbys are at least 5 dB lower than those of the intercity train passbys. Consequently, the results of the present experiment do not support application of a railway bonus to the maglev-train sounds.
Annoyance caused by the sounds of a magnetic levitation train.
Vos, Joos
2004-04-01
In a laboratory study, the annoyance caused by the passby sounds from a magnetic levitation (maglev) train was investigated. The listeners were presented with various sound fragments. The task of the listeners was to respond after each presentation to the question: "How annoying would you find the sound in the preceding period if you were exposed to it at home on a regular basis?" The independent variables were (a) the driving speed of the maglev train (varying from 100 to 400 km/h), (b) the outdoor A-weighted sound exposure level (ASEL) of the passbys (varying from 65 to 90 dB), and (c) the simulated outdoor-to-indoor reduction in sound level (windows open or windows closed). As references to the passby sounds from the maglev train (type Transrapid 08), sounds from road traffic (passenger cars and trucks) and more conventional railway (intercity trains) were included for rating also. Four important results were obtained. Provided that the outdoor ASELs were the same, (1) the annoyance was independent of the driving speed of the maglev train, (2) the annoyance caused by the maglev train was considerably higher than that caused by the intercity train, (3) the annoyance caused by the maglev train was hardly different from that caused by road traffic, and (4) the results (1)-(3) held true both for open or closed windows. On the basis of the present results, it might be expected that the sounds are equally annoying if the ASELs of the maglev-train passbys are at least 5 dB lower than those of the intercity train passbys. Consequently, the results of the present experiment do not support application of a railway bonus to the maglev-train sounds.
Bertucci, Frédéric; Parmentier, Eric; Berten, Laëtitia; Brooker, Rohan M; Lecchini, David
2015-01-01
As environmental sounds are used by larval fish and crustaceans to locate and orientate towards habitat during settlement, variations in the acoustic signature produced by habitats could provide valuable information about habitat quality, helping larvae to differentiate between potential settlement sites. However, very little is known about how acoustic signatures differ between proximate habitats. This study described within- and between-site differences in the sound spectra of five contiguous habitats at Moorea Island, French Polynesia: the inner reef crest, the barrier reef, the fringing reef, a pass and a coastal mangrove forest. Habitats with coral (inner, barrier and fringing reefs) were characterized by a similar sound spectrum with average intensities ranging from 70 to 78 dB re 1 μPa.Hz(-1). The mangrove forest had a lower sound intensity of 70 dB re 1 μPa.Hz(-1) while the pass was characterized by a higher sound level with an average intensity of 91 dB re 1 μPa.Hz(-1). Habitats showed significantly different intensities for most frequencies, and a decreasing intensity gradient was observed from the reef to the shore. While habitats close to the shore showed no significant diel variation in sound intensities, sound levels increased at the pass during the night and barrier reef during the day. These two habitats also appeared to be louder in the North than in the West. These findings suggest that daily variations in sound intensity and across-reef sound gradients could be a valuable source of information for settling larvae. They also provide further evidence that closely related habitats, separated by less than 1 km, can differ significantly in their spectral composition and that these signatures might be typical and conserved along the coast of Moorea.
A little bit less would be great: adolescents' opinion towards music levels.
Gilles, Annick; Thuy, Inge; De Rycke, Els; Van de Heyning, Paul
2014-01-01
Many music organizations are opposed to restrictive noise regulations, because of anxiety related to the possibility of a decrease in the number of adolescents attending music events. The present study consists of two research parts evaluating on one hand the youth's attitudes toward the sound levels at indoor as well as outdoor musical activities and on the other hand the effect of more strict noise regulations on the party behavior of adolescents and young adults. In the first research part, an interview was conducted during a music event at a youth club. A total of 41 young adults were questioned concerning their opinion toward the intensity levels of the music twice: Once when the sound level was 98 dB(A), LAeq, 60min and once when the sound level was increased up to 103 dB(A), LAeq, 60min . Some additional questions concerning hearing protection (HP) use and attitudes toward more strict noise regulations were asked. In the second research part, an extended version of the questionnaire, with addition of some questions concerning the reasons for using/not using HP at music events, was published online and completed by 749 young adults. During the interview, 51% considered a level of 103 dB(A), LAeq, 60min too loud compared with 12% during a level of 98 dB(A), LAeq, 60min . For the other questions, the answers were similar for both research parts. Current sound levels at music venues were often considered as too loud. More than 80% held a positive attitude toward more strict noise regulations and reported that they would not alter their party behavior when the sound levels would decrease. The main reasons given for the low use of HP were that adolescents forget to use them, consider them as uncomfortable and that they never even thought about using them. These results suggest that adolescents do not demand excessive noise levels and that more strict noise regulation would not influence party behavior of youngsters.
NASA Technical Reports Server (NTRS)
Wolfson, N.; Thomasell, A.; Alperson, Z.; Brodrick, H.; Chang, J. T.; Gruber, A.; Ohring, G.
1984-01-01
The impact of introducing satellite temperature sounding data on a numerical weather prediction model of a national weather service is evaluated. A dry five level, primitive equation model which covers most of the Northern Hemisphere, is used for these experiments. Series of parallel forecast runs out to 48 hours are made with three different sets of initial conditions: (1) NOSAT runs, only conventional surface and upper air observations are used; (2) SAT runs, satellite soundings are added to the conventional data over oceanic regions and North Africa; and (3) ALLSAT runs, the conventional upper air observations are replaced by satellite soundings over the entire model domain. The impact on the forecasts is evaluated by three verification methods: the RMS errors in sea level pressure forecasts, systematic errors in sea level pressure forecasts, and errors in subjective forecasts of significant weather elements for a selected portion of the model domain. For the relatively short range of the present forecasts, the major beneficial impacts on the sea level pressure forecasts are found precisely in those areas where the satellite sounding are inserted and where conventional upper air observations are sparse. The RMS and systematic errors are reduced in these regions. The subjective forecasts of significant weather elements are improved with the use of the satellite data. It is found that the ALLSAT forecasts are of a quality comparable to the SAR forecasts.
Acoustic Modeling for Aqua Ventus I off Monhegan Island, ME
DOE Office of Scientific and Technical Information (OSTI.GOV)
Whiting, Jonathan M.; Hanna, Luke A.; DeChello, Nicole L.
2013-10-31
The DeepCwind consortium, led by the University of Maine, was awarded funding under the US Department of Energy’s Offshore Wind Advanced Technology Demonstration Program to develop two floating offshore wind turbines in the Gulf of Maine equipped with Goldwind 6 MW direct drive turbines, as the Aqua Ventus I project. The Goldwind turbines have a hub height of 100 m. The turbines will be deployed in Maine State waters, approximately 2.9 miles off Monhegan Island; Monhegan Island is located roughly 10 miles off the coast of Maine. In order to site and permit the offshore turbines, the acoustic output mustmore » be evaluated to ensure that the sound will not disturb residents on Monhegan Island, nor input sufficient sound levels into the nearby ocean to disturb marine mammals. This initial assessment of the acoustic output focuses on the sound of the turbines in air by modeling the assumed sound source level, applying a sound propagation model, and taking into account the distance from shore.« less
200 kHz Commercial Sonar Systems Generate Lower Frequency Side Lobes Audible to Some Marine Mammals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deng, Zhiqun; Southall, Brandon; Carlson, Thomas J.
2014-04-15
The spectral properties of pulses transmitted by three commercially available 200 kHz echo sounders were measured to assess the possibility that sound energy in below the center (carrier) frequency might be heard by marine mammals. The study found that all three sounders generated sound at frequencies below the center frequency and within the hearing range of some marine mammals and that this sound was likely detectable by the animals over limited ranges. However, at standard operating source levels for the sounders, the sound below the center frequency was well below potentially harmful levels. It was concluded that the sounds generatedmore » by the sounders could affect the behavior of marine mammals within fairly close proximity to the sources and that that the blanket exclusion of echo sounders from environmental impact analysis based solely on the center frequency output in relation to the range of marine mammal hearing should be reconsidered.« less
Blue whales respond to simulated mid-frequency military sonar.
Goldbogen, Jeremy A; Southall, Brandon L; DeRuiter, Stacy L; Calambokidis, John; Friedlaender, Ari S; Hazen, Elliott L; Falcone, Erin A; Schorr, Gregory S; Douglas, Annie; Moretti, David J; Kyburg, Chris; McKenna, Megan F; Tyack, Peter L
2013-08-22
Mid-frequency military (1-10 kHz) sonars have been associated with lethal mass strandings of deep-diving toothed whales, but the effects on endangered baleen whale species are virtually unknown. Here, we used controlled exposure experiments with simulated military sonar and other mid-frequency sounds to measure behavioural responses of tagged blue whales (Balaenoptera musculus) in feeding areas within the Southern California Bight. Despite using source levels orders of magnitude below some operational military systems, our results demonstrate that mid-frequency sound can significantly affect blue whale behaviour, especially during deep feeding modes. When a response occurred, behavioural changes varied widely from cessation of deep feeding to increased swimming speed and directed travel away from the sound source. The variability of these behavioural responses was largely influenced by a complex interaction of behavioural state, the type of mid-frequency sound and received sound level. Sonar-induced disruption of feeding and displacement from high-quality prey patches could have significant and previously undocumented impacts on baleen whale foraging ecology, individual fitness and population health.
Sound propagation elements in evaluation of en route noise of advanced turbofan aircraft
NASA Technical Reports Server (NTRS)
Sutherland, Louis C.; Wesler, John
1990-01-01
Cruise noise from an advanced turboprop aircraft is reviewed on the basis of available wind tunnel data to estimate the aircraft noise signature at the source. Available analytical models are used to evaluate the sound levels at the ground. The analysis allows reasonable estimates to be made of the community noise levels that might be generated during cruise by such aircraft, provides the basis for preliminary comparisons with available data on noise of existing aircraft during climb and helps to identify the dominant elements of the sound propagation models applicable to this situation.
NASA Technical Reports Server (NTRS)
Lanzi, R. James; Vincent, Brett T.
1993-01-01
The relationship between actual and predicted re-entry maximum dynamic pressure is characterized using a probability density function and a cumulative distribution function derived from sounding rocket flight data. This paper explores the properties of this distribution and demonstrates applications of this data with observed sounding rocket re-entry body damage characteristics to assess probabilities of sustaining various levels of heating damage. The results from this paper effectively bridge the gap existing in sounding rocket reentry analysis between the known damage level/flight environment relationships and the predicted flight environment.
Garinis, Angela C; Liao, Selena; Cross, Campbell P; Galati, Johnathan; Middaugh, Jessica L; Mace, Jess C; Wood, Anna-Marie; McEvoy, Lindsey; Moneta, Lauren; Lubianski, Troy; Coopersmith, Noe; Vigo, Nicholas; Hart, Christopher; Riddle, Artur; Ettinger, Olivia; Nold, Casey; Durham, Heather; MacArthur, Carol; McEvoy, Cynthia; Steyger, Peter S
2017-06-01
Hearing loss rates in infants admitted to neonatal intensive care units (NICU) run at 2-15%, compared to 0.3% in full-term births. The etiology of this difference remains poorly understood. We examined whether the level of ambient sound and/or cumulative gentamicin (an aminoglycoside) exposure affect NICU hearing screening results, as either exposure can cause acquired, permanent hearing loss. We hypothesized that higher levels of ambient sound in the NICU, and/or gentamicin dosing, increase the risk of referral on the distortion product otoacoustic emission (DPOAE) assessments and/or automated auditory brainstem response (AABR) screens. This was a prospective pilot outcomes study of 82 infants (<37 weeks gestational age) admitted to the NICU at Oregon Health & Science University. An ER-200D sound pressure level dosimeter was used to collect daily sound exposure in the NICU for each neonate. Gentamicin dosing was also calculated for each infant, including the total daily dose based on body mass (mg/kg/day), as well as the total number of treatment days. DPOAE and AABR assessments were conducted prior to discharge to evaluate hearing status. Exclusion criteria included congenital infections associated with hearing loss, and congenital craniofacial or otologic abnormalities. The mean level of ambient sound was 62.9 dBA (range 51.8-70.6 dBA), greatly exceeding American Academy of Pediatrics (AAP) recommendation of <45.0 dBA. More than 80% of subjects received gentamicin treatment. The referral rate for (i) AABRs, (frequency range: ∼1000-4000 Hz), was 5%; (ii) DPOAEs with a broad F2 frequency range (2063-10031 Hz) was 39%; (iii) DPOAEs with a low-frequency F2 range (<4172 Hz) was 29%, and (iv) DPOAEs with a high-frequency F2 range (>4172 Hz) was 44%. DPOAE referrals were significantly greater for infants receiving >2 days of gentamicin dosing compared to fewer doses (p = 0.004). The effect of sound exposure and gentamicin treatment on hearing could not be determined due to the low number of NICU infants without gentamicin exposure (for control comparisons). All infants were exposed to higher levels of ambient sound that substantially exceed AAP guidelines. More referrals were generated by DPOAE assessments than with AABR screens, with significantly more DPOAE referrals with a high-frequency F2 range, consistent with sound- and/or gentamicin-induced cochlear dysfunction. Adding higher frequency DPOAE assessments to existing NICU hearing screening protocols could better identify infants at-risk for ototoxicity. Copyright © 2017 Elsevier B.V. All rights reserved.
Garinis, Angela C.; Liao, Selena; Cross, Campbell P.; Galati, Johnathan; Middaugh, Jessica L.; Mace, Jess C.; Wood, Anna-Marie; McEvoy, Lindsey; Moneta, Lauren; Lubianski, Troy; Coopersmith, Noe; Vigo, Nicholas; Hart, Christopher; Riddle, Artur; Ettinger, Olivia; Nold, Casey; Durham, Heather; MacArthur, Carol; McEvoy, Cynthia; Steyger, Peter S.
2017-01-01
Objective Hearing loss rates in infants admitted to neonatal intensive care units (NICU) run at 2–15%, compared to 0.3% in full-term births. The etiology of this difference remains poorly understood. We examined whether the level of ambient sound and/or cumulative gentamicin (an aminoglycoside) exposure affect NICU hearing screening results, as either exposure can cause acquired, permanent hearing loss. We hypothesized that higher levels of ambient sound in the NICU, and/or gentamicin dosing, increase the risk of referral on the distortion product otoacoustic emission (DPOAE) assessments and/or automated auditory brainstem response (AABR) screens. Methods This was a prospective pilot outcomes study of 82 infants (<37 weeks gestational age) admitted to the NICU at Oregon Health & Science University. An ER-200D sound pressure level dosimeter was used to collect daily sound exposure in the NICU for each neonate. Gentamicin dosing was also calculated for each infant, including the total daily dose based on body mass (mg/kg/day), as well as the total number of treatment days. DPOAE and AABR assessments were conducted prior to discharge to evaluate hearing status. Exclusion criteria included congenital infections associated with hearing loss, and congenital craniofacial or otologic abnormalities. Results The mean level of ambient sound was 62.9 dBA (range 51.8–70.6 dBA), greatly exceeding American Academy of Pediatrics (AAP) recommendation of <45.0 dBA. More than 80% of subjects received gentamicin treatment. The referral rate for (i) AABRs, (frequency range: ~1000–4000 Hz), was 5%; (ii) DPOAEs with a broad F2 frequency range (2063–10031 Hz) was 39%; (iii) DPOAEs with a low-frequency F2 range (<4172 Hz) was 29%, and (iv) DPOAEs with a high-frequency F2 range (>4172 Hz) was 44%. DPOAE referrals were significantly greater for infants receiving >2 days of gentamicin dosing compared to fewer doses (p= 0.004). The effect of sound exposure and gentamicin treatment on hearing could not be determined due to the low number of NICU infants without gentamicin exposure (for control comparisons). Conclusion All infants were exposed to higher levels of ambient sound that substantially exceed AAP guidelines. More referrals were generated by DPOAE assessments than with AABR screens, with significantly more DPOAE referrals with a high-frequency F2 range, consistent with sound- and/or gentamicin-induced cochlear dysfunction. Adding higher frequency DPOAE assessments to existing NICU hearing screening protocols could better identify at-risk infants to be referred for diagnostic evaluation. PMID:28483249
The impact of sound in modern multiline video slot machine play.
Dixon, Mike J; Harrigan, Kevin A; Santesso, Diane L; Graydon, Candice; Fugelsang, Jonathan A; Collins, Karen
2014-12-01
Slot machine wins and losses have distinctive, measurable, physiological effects on players. The contributing factors to these effects remain under-explored. We believe that sound is one of these key contributing factors. Sound plays an important role in reinforcement, and thus on arousal level and stress response of players. It is the use of sound for positive reinforcement in particular that we believe influences the player. In the current study, we investigate the role that sound plays in psychophysical responses to slot machine play. A total of 96 gamblers played a slot machine simulator with and without sound being paired with reinforcement. Skin conductance responses and heart rate, as well as subjective judgments about the gambling experience were examined. The results showed that the sound influenced the arousal of participants both psychophysically and psychologically. The sound also influenced players' preferences, with the majority of players preferring to play slot machines that were accompanied by winning sounds. The sounds also caused players to significantly overestimate the number of times they won while playing the slot machine.
The Measurement of the Oral and Nasal Sound Pressure Levels of Speech
ERIC Educational Resources Information Center
Clarke, Wayne M.
1975-01-01
A nasal separator was used to measure the oral and nasal components in the speech of a normal adult Australian population. Results indicated no difference in oral and nasal sound pressure levels for read versus spontaneous speech samples; however, females tended to have a higher nasal component than did males. (Author/TL)
40 CFR 205.52 - Vehicle noise emission standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... sound emissions in excess of the levels indicated. Effective date Level (i) January 1, 1979 83 dBA. (ii) January 1, 1988 80 dBA. (b) The standards set forth in paragraph (a) of this section refer to the sound emissions as measured in accordance with the procedures prescribed in § 205.54-1,2. (c) Every manufacturer...
40 CFR 205.52 - Vehicle noise emission standards.
Code of Federal Regulations, 2011 CFR
2011-07-01
... sound emissions in excess of the levels indicated. Effective date Level (i) January 1, 1979 83 dBA. (ii) January 1, 1988 80 dBA. (b) The standards set forth in paragraph (a) of this section refer to the sound emissions as measured in accordance with the procedures prescribed in § 205.54-1,2. (c) Every manufacturer...
Characterization of Underwater Sounds Produced by a Backhoe Dredge Excavating Rock and Gravel
2012-12-01
bathymetry, hydrodynamic conditions, prevalence of non-dredging ambient sounds), this study fills important knowledge gaps that contribute to better... Beaver Mackenzie, peak spectral levels were 122 dB at 190 m with a peak frequency of 120 Hz. Received levels in the 20- to 1000-Hz band were 133 dB
Range of sound levels in the outdoor environment
Lewis S. Goodfriend
1977-01-01
Current methods of measuring and rating noise in a metropolitan area are examined, including real-time spectrum analysis and sound-level integration, producing a single-number value representing the noise impact for each hour or each day. Methods of noise rating for metropolitan areas are reviewed, and the various measures from multidimensional rating methods such as...
Music as Active Information Resource for Players in Video Games
ERIC Educational Resources Information Center
Nagorsnick, Marian; Martens, Alke
2015-01-01
In modern video games, music can come in different shapes: it can be developed on a very high compositional level, with sophisticated sound elements like in professional film music; it can be developed on a very coarse level, underlying special situations (like danger or attack); it can also be automatically generated by sound engines. However, in…
ERIC Educational Resources Information Center
McKinnon, David H.; McLeod, Sharynne; Reilly, Sheena
2007-01-01
Purpose: The aims of this study were threefold: to report teachers' estimates of the prevalence of speech disorders (specifically, stuttering, voice, and speech-sound disorders); to consider correspondence between the prevalence of speech disorders and gender, grade level, and socioeconomic status; and to describe the level of support provided to…
20 Years of sea-levels, accretion, and vegetation on two Long Island Sound salt marshes
The long-term 1939-2013 rate of RSLR (Relative Sea-Level Rise) at the New London, CT tide gauge is ~2.6 mm/yr, near the maximum rate of salt marsh accretion reported in eastern Long Island Sound salt marshes. Consistent with recent literature RSLR at New London has accelerated si...
NASA Technical Reports Server (NTRS)
Heffner, R. J.
1998-01-01
This is the Engineering Test Report, AMSU-AL METSAT Instrument (S/N 105) Qualification Level Vibration Tests of December 1998 (S/0 605445, OC-419), for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A).
The Helmholtz resonance behavior of single and multiple rooms
NASA Technical Reports Server (NTRS)
Hubbard, H. H.; Shepherd, K. P.
1986-01-01
The results of exploratory measurements of the noise fields inside rooms which are excited to resonance either acoustically or mechanically are presented. The data illustrate the nature and extent of the sound pressure level enhancements in single rooms and also how multiple rooms may resonate by means of either acoustic or mechanical coupling. Sound pressure level enhancements of about 5 dB were measured during resonance of rooms having flexible walls. For such conditions the sound pressure levels in the room were essentially uniform and in phase. Variability of up to 20 dB was measured in a room hallway complex having significant acoustic interactions. Resonant frequency prediction methods which work well at model scale, give only fair results for rooms.
Lewis, James W.; Talkington, William J.; Tallaksen, Katherine C.; Frum, Chris A.
2012-01-01
Whether viewed or heard, an object in action can be segmented as a distinct salient event based on a number of different sensory cues. In the visual system, several low-level attributes of an image are processed along parallel hierarchies, involving intermediate stages wherein gross-level object form and/or motion features are extracted prior to stages that show greater specificity for different object categories (e.g., people, buildings, or tools). In the auditory system, though relying on a rather different set of low-level signal attributes, meaningful real-world acoustic events and “auditory objects” can also be readily distinguished from background scenes. However, the nature of the acoustic signal attributes or gross-level perceptual features that may be explicitly processed along intermediate cortical processing stages remain poorly understood. Examining mechanical and environmental action sounds, representing two distinct non-biological categories of action sources, we had participants assess the degree to which each sound was perceived as object-like versus scene-like. We re-analyzed data from two of our earlier functional magnetic resonance imaging (fMRI) task paradigms (Engel et al., 2009) and found that scene-like action sounds preferentially led to activation along several midline cortical structures, but with strong dependence on listening task demands. In contrast, bilateral foci along the superior temporal gyri (STG) showed parametrically increasing activation to action sounds rated as more “object-like,” independent of sound category or task demands. Moreover, these STG regions also showed parametric sensitivity to spectral structure variations (SSVs) of the action sounds—a quantitative measure of change in entropy of the acoustic signals over time—and the right STG additionally showed parametric sensitivity to measures of mean entropy and harmonic content of the environmental sounds. Analogous to the visual system, intermediate stages of the auditory system appear to process or extract a number of quantifiable low-order signal attributes that are characteristic of action events perceived as being object-like, representing stages that may begin to dissociate different perceptual dimensions and categories of every-day, real-world action sounds. PMID:22582038
Kirk, D L; Yates, G K
1998-09-01
Electrically evoked oto-acoustic emissions (EEOAEs) are sounds present in the ear canal when ac current is passed into the cochlea. EEOAEs are attributed to the activation of fast electromotile responses in outer hair cells (OHCs). An interesting property of EEOAEs is the phenomenon of "acoustic enhancement," where the emission amplitude is increased by moderate-level sound [D. C. Mountain and A. E. Hubbard, Hear. Res. 42, 195-202 (1989)]. In this report a form of enhancement is described which occurs with displacements of the basilar membrane toward scala vestibuli, during amplitude modulation of the EEOAE waveform by low-frequency tones. This "SV-bias enhancement" possibly consists of two components: (i) a low-level component induced by sound at levels which produce nonlinear growth of the cochlear microphonic and which may be equivalent to the "acoustic enhancement" described previously, and (ii) a high-level component which occurs at sound levels well above those which cause saturation of the cochlear microphonic. The low-level component could be explained by either an increased access of the extrinsically applied current to a membrane-based source of OHC motility, perhaps coupled with a reduction in negative feedback, or an increase in electromotile output during scala vestibuli displacements, but the origin of the high-level component is obscure.
Assessment of noise in the airplane cabin environment.
Zevitas, Christopher D; Spengler, John D; Jones, Byron; McNeely, Eileen; Coull, Brent; Cao, Xiaodong; Loo, Sin Ming; Hard, Anna-Kate; Allen, Joseph G
2018-03-15
To measure sound levels in the aircraft cabin during different phases of flight. Sound level was measured on 200 flights, representing six aircraft groups using continuous monitors. A linear mixed-effects model with random intercept was used to test for significant differences in mean sound level by aircraft model and across each flight phase as well as by flight phase, airplane type, measurement location and proximity to engine noise. Mean sound levels across all flight phases and aircraft groups ranged from 37.6 to >110 dB(A) with a median of 83.5 dB(A). Significant differences in noise levels were also observed based on proximity to the engines and between aircraft with fuselage- and wing mounted engines. Nine flights (4.5%) exceeded the recommended 8-h TWA exposure limit of 85 dB(A) by the NIOSH and ACGIH approach, three flights (1.5%) exceeded the 8-h TWA action level of 85 dB(A) by the OSHA approach, and none of the flights exceeded the 8-h TWA action level of 90 dB(A) by the OSHA PEL approach. Additional characterization studies, including personal noise dosimetry, are necessary to document accurate occupational exposures in the aircraft cabin environment and identify appropriate response actions. FAA should consider applying the more health-protective NIOSH/ACGIH occupational noise recommendations to the aircraft cabin environment.
ERIC Educational Resources Information Center
Hempstead, John Orson
The level of abstraction of the message and the educational effects of five media presentations (Print, verbal sound, print/pictures, print/verbal sound, and pictures/verbal sound) were experimentally investigated. The media components were presented singly or in combination to 6th grade students in a uniformly controlled consistent environment.…
Study of sound-absorbing properties of glass-fiber reinforced materials used in engineering
NASA Astrophysics Data System (ADS)
Egorova, V. E.; Habibova, R. R.; Shafigullin, L. N.
2017-09-01
Modern engineering makes high demands to the noise level in the passenger compartment or cabin of KAMAZ. An effective means of dealing with noise is to use sound absorbing materials produced by the automotive industry. To increase sound-absorbing capacity of materials and structures using glass fibre reinforced polyurethane foams (PUF) obtained by the technology Fiber Composite Spraying.
49 CFR Appendix E to Part 222 - Requirements for Wayside Horns
Code of Federal Regulations, 2011 CFR
2011-10-01
..., indicates that the system is not operating as intended; 4. Horn system must provide a minimum sound level of... locomotive engineer to sound the locomotive horn for at least 15 seconds prior to arrival at the crossing in...; 5. Horn system must sound at a minimum of 15 seconds prior to the train's arrival at the crossing...
49 CFR Appendix E to Part 222 - Requirements for Wayside Horns
Code of Federal Regulations, 2010 CFR
2010-10-01
..., indicates that the system is not operating as intended; 4. Horn system must provide a minimum sound level of... locomotive engineer to sound the locomotive horn for at least 15 seconds prior to arrival at the crossing in...; 5. Horn system must sound at a minimum of 15 seconds prior to the train's arrival at the crossing...
The Effect of Music and Sound Effects on the Listening Comprehension of Fourth Grade Students.
ERIC Educational Resources Information Center
Mann, Raymond E.
This study was designed to determine if the addition of music and sound effects to recorded stories increased the comprehension and retention of information presented on tape to fourth grade students at three levels of reading ability. Two versions of four narrated stories were recorded, one version with music and sound effects, the other with…
Salavitabar, Arash; Haidet, Kim Kopenhaver; Adkins, Cherie S; Susman, Elizabeth J; Palmer, Charles; Storm, Hanne
2010-06-01
To evaluate the utility of skin conductance (SC) as a measure of autonomic arousal to sound stimuli in preterm infants. A pilot cross-sectional, correlations study. Eleven preterm infants with a mean gestational age of 31.6 weeks without anomalies or conditions associated with neurodevelopmental delay composed the sample. On days 5-7 of life, the following infant responses were simultaneously recorded in response to naturally occurring sound stimuli in the NICU: real-time measurements of heart rate, respiratory rate, and oxygen saturations; sympathetic-mediated sweating via SC; and behavioral responses using the Newborn Individualized Developmental Care and Assessment Program naturalistic observation. Baseline sound levels (BSL, <55 dBA) and high sound levels (HSL, >65 dBA) were measured to index patterns of response during a nonhandling period preceding care. Mean heart rate during precare was directly associated with higher SC increases to sound stimuli (r[10] = 0.697, P = .017). The SC during HSL was significantly higher than that during BSL (P < .0001). Males demonstrated higher SC increases to sound stimuli than females (P = .030). Changes in SC induced by increases in sound intensity were associated with lower attention responses (r[10] = -0.92, P < .0001) and lower summated behavioral responses (r[10] = -0.59, P = .054). SC provides a noninvasive, sensitive measure of sympathetic arousal that may not be apparent in behavioral cues or states, or determined by standard physiological responses alone.
Puget Sound Dissolved Oxygen Modeling Study: Development of an Intermediate-Scale Hydrodynamic Model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Zhaoqing; Khangaonkar, Tarang; Labiosa, Rochelle G.
2010-11-30
The Washington State Department of Ecology contracted with Pacific Northwest National Laboratory to develop an intermediate-scale hydrodynamic and water quality model to study dissolved oxygen and nutrient dynamics in Puget Sound and to help define potential Puget Sound-wide nutrient management strategies and decisions. Specifically, the project is expected to help determine 1) if current and potential future nitrogen loadings from point and non-point sources are significantly impairing water quality at a large scale and 2) what level of nutrient reductions are necessary to reduce or dominate human impacts to dissolved oxygen levels in the sensitive areas. In this study, anmore » intermediate-scale hydrodynamic model of Puget Sound was developed to simulate the hydrodynamics of Puget Sound and the Northwest Straits for the year 2006. The model was constructed using the unstructured Finite Volume Coastal Ocean Model. The overall model grid resolution within Puget Sound in its present configuration is about 880 m. The model was driven by tides, river inflows, and meteorological forcing (wind and net heat flux) and simulated tidal circulations, temperature, and salinity distributions in Puget Sound. The model was validated against observed data of water surface elevation, velocity, temperature, and salinity at various stations within the study domain. Model validation indicated that the model simulates tidal elevations and currents in Puget Sound well and reproduces the general patterns of the temperature and salinity distributions.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Efroymson, Rebecca Ann; Hargrove, William Walter; Suter, Glenn
A multi-stressor risk assessment was conducted at Yuma Proving Ground, Arizona, as a demonstration of the Military Ecological Risk Assessment Framework. The focus of the assessment was a testing program at Cibola Range, which involved an Apache Longbow helicopter firing Hellfire missiles at moving targets, M60-A1 tanks. This paper focuses on the wildlife risk assessment for the helicopter overflight. The primary stressors were sound and the view of the aircraft. Exposure to desert mule deer (Odocoileus hemionus crooki) was quantified using Air Force sound contour programs NOISEMAP and MR_NMAP, which gave very different results. Slant distance from helicopters to deermore » was also used as a measure of exposure that integrated risk from sound and view of the aircraft. Exposure-response models for the characterization of effects consisted of behavioral thresholds in sound exposure level or maximum sound level units or slant distance. Available sound thresholds were limited for desert mule deer, but a distribution of slant-distance thresholds was available for ungulates. The risk characterization used a weight-of-evidence approach and concluded that risk to mule deer behavior from the Apache overflight is uncertain, but that no risk to mule deer abundance and reproduction is expected.« less
Auditory performance in an open sound field
NASA Astrophysics Data System (ADS)
Fluitt, Kim F.; Letowski, Tomasz; Mermagen, Timothy
2003-04-01
Detection and recognition of acoustic sources in an open field are important elements of situational awareness on the battlefield. They are affected by many technical and environmental conditions such as type of sound, distance to a sound source, terrain configuration, meteorological conditions, hearing capabilities of the listener, level of background noise, and the listener's familiarity with the sound source. A limited body of knowledge about auditory perception of sources located over long distances makes it difficult to develop models predicting auditory behavior on the battlefield. The purpose of the present study was to determine the listener's abilities to detect, recognize, localize, and estimate distances to sound sources from 25 to 800 m from the listing position. Data were also collected for meteorological conditions (wind direction and strength, temperature, atmospheric pressure, humidity) and background noise level for each experimental trial. Forty subjects (men and women, ages 18 to 25) participated in the study. Nine types of sounds were presented from six loudspeakers in random order; each series was presented four times. Partial results indicate that both detection and recognition declined at distances greater than approximately 200 m and distance estimation was grossly underestimated by listeners. Specific results will be presented.
Environmental Assessment: Installation Development at Sheppard Air Force Base, Texas
2007-05-01
column, or in topographic depressions. Water is then utilized by plants and is respired, or it moves slowly into groundwater and/or eventually to surface...water bodies where it slowly moves through the hydrologic cycle. Removal of vegetation decreases infiltration into the soil column and thereby...School District JP-4 jet propulsion fuel 4 kts knots Ldn Day- Night Average Sound Level Leq equivalent noise level Lmax maximum sound level lb pound
Christiaens, Véronique; De Bruyn, Hugo; Thevissen, Eric; Koole, Sebastiaan; Dierens, Melissa; Cosyn, Jan
2018-01-01
The accuracy of analogue and especially digital intra-oral radiography in assessing interdental bone level needs further documentation. The aim of this study was to compare clinical and radiographic bone level assessment to intra-surgical bone level registration (1) and to identify the clinical variables rendering interdental bone level assessment inaccurate (2). The study sample included 49 interdental sites in 17 periodontitis patients. Evaluation methods included vertical relative probing attachment level (RAL-V), analogue and digital intra-oral radiography and bone sounding without and with flap elevation. The latter was considered the true bone level. Five examiners evaluated all radiographs. Significant underestimation of the true bone level was observed for all evaluation methods pointing to 2.7 mm on average for analogue radiography, 2.5 mm for digital radiography, 1.8 mm for RAL-V and 0.6 mm for bone sounding without flap elevation (p < 0.001). Radiographic underestimation of the true bone level was higher in the (pre)molar region (p ≤ 0.047) and increased with defect depth (p < 0.001). Variation between clinicians was huge (range analogue radiography 2.2-3.2 mm; range digital radiography 2.1-3.0 mm). All evaluation methods significantly underestimated the true bone level. Bone sounding was most accurate, whereas intra-oral radiographs were least accurate. Deep periodontal defects in the (pre)molar region were most underrated by intra-oral radiography. Bone sounding had the highest accuracy in assessing interdental bone level.
Macías, Silvio; Hechavarría, Julio C; Cobo, Ariadna; Mora, Emanuel C
2014-03-01
In the auditory system, tuning to sound level appears in the form of non-monotonic response-level functions that depict the response of a neuron to changing sound levels. Neurons with non-monotonic response-level functions respond best to a particular sound pressure level (defined as "best level" or level evoking the maximum response). We performed a comparative study on the location and basic functional organization of the auditory cortex in the gleaning bat, Macrotus waterhousii, and the aerial-hawking bat, Molossus molossus. Here, we describe the response-level function of cortical units in these two species. In the auditory cortices of M. waterhousii and M. molossus, the characteristic frequency of the units increased from caudal to rostral. In M. waterhousii, there was an even distribution of characteristic frequencies while in M. molossus there was an overrepresentation of frequencies present within echolocation pulses. In both species, most of the units showed best levels in a narrow range, without an evident topography in the amplitopic organization, as described in other species. During flight, bats decrease the intensity of their emitted pulses when they approach a prey item or an obstacle resulting in maintenance of perceived echo intensity. Narrow level tuning likely contributes to the extraction of echo amplitudes facilitating echo-intensity compensation. For aerial-hawking bats, like M. molossus, receiving echoes within the optimal sensitivity range can help the bats to sustain consistent analysis of successive echoes without distortions of perception caused by changes in amplitude. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Clevenson, S. A.; Leatherwood, J. D.
1979-01-01
The effects of helicopter interior noise on passenger annoyance were studied. Both reverie and listening situations were studied as well as the relative effectiveness of several descriptors (i.e., overall sound pressure level, A-weighted sound pressure level, and speech interference level) for quantifying annoyance response for these situations. The noise stimuli were based upon recordings of the interior noise of a civil helicopter research aircraft. These noises were presented at levels ranging from approximately 68 to 86 dB(A) with various gear clash tones selectively attenuated to give a range of spectra. Results indicated that annoyance during a listening condition is generally higher than annoyance during a reverie condition for corresponding interior noise environments. Attenuation of the planetary gear clash tone results in increases in listening performance but has negligible effect upon annoyance for a given noise level. The noise descriptor most effective for estimating annoyance response under conditions of reverie and listening situations is shown to be the A-weighted sound pressure level.
Audiovisual associations alter the perception of low-level visual motion
Kafaligonul, Hulusi; Oluk, Can
2015-01-01
Motion perception is a pervasive nature of vision and is affected by both immediate pattern of sensory inputs and prior experiences acquired through associations. Recently, several studies reported that an association can be established quickly between directions of visual motion and static sounds of distinct frequencies. After the association is formed, sounds are able to change the perceived direction of visual motion. To determine whether such rapidly acquired audiovisual associations and their subsequent influences on visual motion perception are dependent on the involvement of higher-order attentive tracking mechanisms, we designed psychophysical experiments using regular and reverse-phi random dot motions isolating low-level pre-attentive motion processing. Our results show that an association between the directions of low-level visual motion and static sounds can be formed and this audiovisual association alters the subsequent perception of low-level visual motion. These findings support the view that audiovisual associations are not restricted to high-level attention based motion system and early-level visual motion processing has some potential role. PMID:25873869
Effects of HearFones on speaking and singing voice quality.
Laukkanen, Anne-Maria; Mickelson, Nils Peter; Laitala, Marja; Syrjä, Tiina; Salo, Arla; Sihvo, Marketta
2004-12-01
HearFones (HF) have been designed to enhance auditory feedback during phonation. This study investigated the effects of HF (1) on sound perceivable by the subject, (2) on voice quality in reading and singing, and (3) on voice production in speech and singing at the same pitch and sound level. Test 1: Text reading was recorded with two identical microphones in the ears of a subject. One ear was covered with HF, and the other was free. Four subjects attended this test. Tests 2 and 3: A reading sample was recorded from 13 subjects and a song from 12 subjects without and with HF on. Test 4: Six females repeated [pa:p:a] in speaking and singing modes without and with HF on same pitch and sound level. Long-term average spectra were made (Tests 1-3), and formant frequencies, fundamental frequency, and sound level were measured (Tests 2 and 3). Subglottic pressure was estimated from oral pressure in [p], and simultaneously electroglottography (EGG) was registered during voicing on [a:] (Test 4). Voice quality in speech and singing was evaluated by three professional voice trainers (Tests 2-4). HF seemed to enhance sound perceivable at the whole range studied (0-8 kHz), with the greatest enhancement (up to ca 25 dB) being at 1-3 kHz and at 4-7 kHz. The subjects tended to decrease loudness with HF (when sound level was not being monitored). In more than half of the cases, voice quality was evaluated "less strained" and "better controlled" with HF. When pitch and loudness were constant, no clear differences were heard but closed quotient of the EGG signal was higher and the signal more skewed, suggesting a better glottal closure and/or diminished activity of the thyroarytenoid muscle.
Changing noise levels in a high CO2/lower pH ocean
NASA Astrophysics Data System (ADS)
Brewer, P. G.; Hester, K. C.; Peltzer, E. T.; Kirkwood, W. J.
2008-12-01
We show that ocean acidification from fossil fuel CO2 invasion and from increased respiration/reduced ventilation, has significantly reduced ocean sound absorption and thus increased ocean noise levels in the kHz frequency range. Below 10 kHz, sound absorption occurs due to well known chemical relaxations in the B(OH)3/B(OH)4- and HCO3-/CO32- systems. The pH dependence of these chemical relaxations results in decreased sound absorption (α = dB/km) as the ocean becomes more acidic from increased CO2 levels. The scale of surface ocean pH change today from the +105 ppmv change in atmospheric CO2 is about - 0.12 pH, resulting in frequency dependent decreases in sound absorption that now exceed 12% over pre- industrial. Under reasonable projections of future fossil fuel CO2 emissions and other sources a pH change of 0.3 units or more can be anticipated by mid-century, resulting in a decrease in α by almost 40%. Increases in water temperature have a smaller effect but also contribute to decreased sound absorption. Combining a lowering of 0.3 pH units with an increase of 3°C, α will decrease further to almost 45%. Ambient noise levels in the ocean within the auditory range critical for environmental, military, and economic interests are set to increase significantly due to the combined effects of decreased absorption and increasing sources from mankind's activities. Incorporation of sound absorption in modeling future ocean scenarios (R. Zeebe, personal communication) and long-term monitoring possibly with the aid of modern cabled observatories can give insights in how ocean noise will continue to change and its effect on groups such as marine mammals which communicate in the affected frequency range.
Horizontal sound localization in cochlear implant users with a contralateral hearing aid.
Veugen, Lidwien C E; Hendrikse, Maartje M E; van Wanrooij, Marc M; Agterberg, Martijn J H; Chalupper, Josef; Mens, Lucas H M; Snik, Ad F M; John van Opstal, A
2016-06-01
Interaural differences in sound arrival time (ITD) and in level (ILD) enable us to localize sounds in the horizontal plane, and can support source segregation and speech understanding in noisy environments. It is uncertain whether these cues are also available to hearing-impaired listeners who are bimodally fitted, i.e. with a cochlear implant (CI) and a contralateral hearing aid (HA). Here, we assessed sound localization behavior of fourteen bimodal listeners, all using the same Phonak HA and an Advanced Bionics CI processor, matched with respect to loudness growth. We aimed to determine the availability and contribution of binaural (ILDs, temporal fine structure and envelope ITDs) and monaural (loudness, spectral) cues to horizontal sound localization in bimodal listeners, by systematically varying the frequency band, level and envelope of the stimuli. The sound bandwidth had a strong effect on the localization bias of bimodal listeners, although localization performance was typically poor for all conditions. Responses could be systematically changed by adjusting the frequency range of the stimulus, or by simply switching the HA and CI on and off. Localization responses were largely biased to one side, typically the CI side for broadband and high-pass filtered sounds, and occasionally to the HA side for low-pass filtered sounds. HA-aided thresholds better than 45 dB HL in the frequency range of the stimulus appeared to be a prerequisite, but not a guarantee, for the ability to indicate sound source direction. We argue that bimodal sound localization is likely based on ILD cues, even at frequencies below 1500 Hz for which the natural ILDs are small. These cues are typically perturbed in bimodal listeners, leading to a biased localization percept of sounds. The high accuracy of some listeners could result from a combination of sufficient spectral overlap and loudness balance in bimodal hearing. Copyright © 2016 Elsevier B.V. All rights reserved.
Long Island Sound Tropospheric Ozone Study (LISTOS) Fact Sheet
EPA scientists are collaborating on a multi-agency field study to investigate the complex interaction of emissions, chemistry and meteorological factors contributing to elevated ozone levels along the Long Island Sound shoreline.
Is low frequency ocean sound increasing globally?
Miksis-Olds, Jennifer L; Nichols, Stephen M
2016-01-01
Low frequency sound has increased in the Northeast Pacific Ocean over the past 60 yr [Ross (1993) Acoust. Bull. 18, 5-8; (2005) IEEE J. Ocean. Eng. 30, 257-261; Andrew, Howe, Mercer, and Dzieciuch (2002) J. Acoust. Soc. Am. 129, 642-651; McDonald, Hildebrand, and Wiggins (2006) J. Acoust. Soc. Am. 120, 711-717; Chapman and Price (2011) J. Acoust. Soc. Am. 129, EL161-EL165] and in the Indian Ocean over the past decade, [Miksis-Olds, Bradley, and Niu (2013) J. Acoust. Soc. Am. 134, 3464-3475]. More recently, Andrew, Howe, and Mercer's [(2011) J. Acoust. Soc. Am. 129, 642-651] observations in the Northeast Pacific show a level or slightly decreasing trend in low frequency noise. It remains unclear what the low frequency trends are in other regions of the world. In this work, data from the Comprehensive Nuclear-Test Ban Treaty Organization International Monitoring System was used to examine the rate and magnitude of change in low frequency sound (5-115 Hz) over the past decade in the South Atlantic and Equatorial Pacific Oceans. The dominant source observed in the South Atlantic was seismic air gun signals, while shipping and biologic sources contributed more to the acoustic environment at the Equatorial Pacific location. Sound levels over the past 5-6 yr in the Equatorial Pacific have decreased. Decreases were also observed in the ambient sound floor in the South Atlantic Ocean. Based on these observations, it does not appear that low frequency sound levels are increasing globally.
Chrostowski, Michael; Salvi, Richard J.; Allman, Brian L.
2012-01-01
A high dose of sodium salicylate temporarily induces tinnitus, mild hearing loss, and possibly hyperacusis in humans and other animals. Salicylate has well-established effects on cochlear function, primarily resulting in the moderate reduction of auditory input to the brain. Despite decreased peripheral sensitivity and output, salicylate induces a paradoxical enhancement of the sound-evoked field potential at the level of the primary auditory cortex (A1). Previous electrophysiologic studies have begun to characterize changes in thalamorecipient layers of A1; however, A1 is a complex neural circuit with recurrent intracortical connections. To describe the effects of acute systemic salicylate treatment on both thalamic and intracortical sound-driven activity across layers of A1, we applied current-source density (CSD) analysis to field potentials sampled across cortical layers in the anesthetized rat. CSD maps were normally characterized by a large, short-latency, monosynaptic, thalamically driven sink in granular layers followed by a lower amplitude, longer latency, polysynaptic, intracortically driven sink in supragranular layers. Following systemic administration of salicylate, there was a near doubling of both granular and supragranular sink amplitudes at higher sound levels. The supragranular sink amplitude input/output function changed from becoming asymptotic at approximately 50 dB to sharply nonasymptotic, often dominating the granular sink amplitude at higher sound levels. The supragranular sink also exhibited a significant decrease in peak latency, reflecting an acceleration of intracortical processing of the sound-evoked response. Additionally, multiunit (MU) activity was altered by salicylate; the normally onset/sustained MU response type was transformed into a primarily onset response type in granular and infragranular layers. The results from CSD analysis indicate that salicylate significantly enhances sound-driven response via intracortical circuits. PMID:22496535
Park, H K; Bradley, J S
2009-09-01
Subjective ratings of the audibility, annoyance, and loudness of music and speech sounds transmitted through 20 different simulated walls were used to identify better single number ratings of airborne sound insulation. The first part of this research considered standard measures such as the sound transmission class the weighted sound reduction index (R(w)) and variations of these measures [H. K. Park and J. S. Bradley, J. Acoust. Soc. Am. 126, 208-219 (2009)]. This paper considers a number of other measures including signal-to-noise ratios related to the intelligibility of speech and measures related to the loudness of sounds. An exploration of the importance of the included frequencies showed that the optimum ranges of included frequencies were different for speech and music sounds. Measures related to speech intelligibility were useful indicators of responses to speech sounds but were not as successful for music sounds. A-weighted level differences, signal-to-noise ratios and an A-weighted sound transmission loss measure were good predictors of responses when the included frequencies were optimized for each type of sound. The addition of new spectrum adaptation terms to R(w) values were found to be the most practical approach for achieving more accurate predictions of subjective ratings of transmitted speech and music sounds.
Wind-tunnel acoustic results of two rotor models with several tip designs
NASA Technical Reports Server (NTRS)
Martin, R. M.; Connor, A. B.
1986-01-01
A three-phase research program has been undertaken to study the acoustic signals due to the aerodynamic interaction of rotorcraft main rotors and tail rotors. During the first phase, two different rotor models with several interchangeable tips were tested in the Langley 4- by 7-Meter Tunnel on the U.S. Army rotor model system. An extensive acoustic data base was acquired, with special emphasis on blade-vortex interaction (BVI) noise. The details of the experimental procedure, acoustic data acquisition, and reduction are documented. The overall sound pressure level (OASPL) of the high-twist rotor systems is relatively insensitive to flight speed but generally increases with rotor tip-path-plane angle. The OASPL of the high-twist rotors is dominated by acoustic energy in the low-frequency harmonics. The OASPL of the low-twist rotor systems shows more dependence on flight speed than the high-twist rotors, in addition to being quite sensitive to tip-path-plane angle. An integrated band-limited sound pressure level, limited by 500 to 3000 Hz, is a useful metric to quantify the occurrence of BVI noise. The OASPL of the low-twist rotors is strongly influenced by the band-limited sound levels, indicating that the blade-vortex impulsive noise is a dominant noise source for this rotor design. The midfrequency acoustic levels for both rotors show a very strong dependence on rotor tip-path-plane angle. The tip-path-plane angle at which the maximum midfrequency sound level occurs consistently decreases with increasing flight speed. The maximum midfrequency sound level measured at a given location is constant regardless of the flight speed.
Marmel, Frederic; Marrufo-Pérez, Miriam I; Heeren, Jan; Ewert, Stephan; Lopez-Poveda, Enrique A
2018-06-14
The detection of high-frequency spectral notches has been shown to be worse at 70-80 dB sound pressure level (SPL) than at higher levels up to 100 dB SPL. The performance improvement at levels higher than 70-80 dB SPL has been related to an 'ideal observer' comparison of population auditory nerve spike trains to stimuli with and without high-frequency spectral notches. Insofar as vertical localization partly relies on information provided by pinna-based high-frequency spectral notches, we hypothesized that localization would be worse at 70-80 dB SPL than at higher levels. Results from a first experiment using a virtual localization set-up and non-individualized head-related transfer functions (HRTFs) were consistent with this hypothesis, but a second experiment using a free-field set-up showed that vertical localization deteriorates monotonically with increasing level up to 100 dB SPL. These results suggest that listeners use different cues when localizing sound sources in virtual and free-field conditions. In addition, they confirm that the worsening in vertical localization with increasing level continues beyond 70-80 dB SPL, the highest levels tested by previous studies. Further, they suggest that vertical localization, unlike high-frequency spectral notch detection, does not rely on an 'ideal observer' analysis of auditory nerve spike trains. Copyright © 2018 Elsevier B.V. All rights reserved.
Mokri, Yasamin; Worland, Kate; Ford, Mark; Rajan, Ramesh
2015-01-01
Humans can accurately localize sounds even in unfavourable signal-to-noise conditions. To investigate the neural mechanisms underlying this, we studied the effect of background wide-band noise on neural sensitivity to variations in interaural level difference (ILD), the predominant cue for sound localization in azimuth for high-frequency sounds, at the characteristic frequency of cells in rat inferior colliculus (IC). Binaural noise at high levels generally resulted in suppression of responses (55.8%), but at lower levels resulted in enhancement (34.8%) as well as suppression (30.3%). When recording conditions permitted, we then examined if any binaural noise effects were related to selective noise effects at each of the two ears, which we interpreted in light of well-known differences in input type (excitation and inhibition) from each ear shaping particular forms of ILD sensitivity in the IC. At high signal-to-noise ratios (SNR), in most ILD functions (41%), the effect of background noise appeared to be due to effects on inputs from both ears, while for a large percentage (35.8%) appeared to be accounted for by effects on excitatory input. However, as SNR decreased, change in excitation became the dominant contributor to the change due to binaural background noise (63.6%). These novel findings shed light on the IC neural mechanisms for sound localization in the presence of continuous background noise. They also suggest that some effects of background noise on encoding of sound location reported to be emergent in upstream auditory areas can also be observed at the level of the midbrain. PMID:25865218
A Simple Experiment to Explore Standing Waves in a Flexible Corrugated Sound Tube
NASA Astrophysics Data System (ADS)
Amorim, Maria Eva; Sousa, Teresa Delmira; Carvalho, P. Simeão; Sousa, Adriano Sampaioe
2011-09-01
Sound tubes, pipes, and singing rods are used as musical instruments and as toys to perform amusing experiments. In particular, corrugated tubes present unique characteristics with respect to the sounds they can produce; that is why they have been studied so intensively, both at theoretical and experimental levels.1-4 Experimental studies usually involve expensive and sophisticated equipment that is out of reach of school laboratory facilities.3-6 In this paper we show how to investigate quantitatively the sounds produced by a flexible sound tube corrugated on the inside by using educational equipment readily available in school laboratories, such as the oscilloscope, the microphone, the anemometer, and the air pump. We show that it is possible for students to study the discontinuous spectrum of sounds produced by a flexible corrugated tube and go even further, computing the speed of sound in air with a simple experimental procedure.
MP3 player listening habits of 17 to 23 year old university students.
McNeill, Kylie; Keith, Stephen E; Feder, Katya; Konkle, Anne T M; Michaud, David S
2010-08-01
This study evaluated the potential risk to hearing associated with the use of portable digital audio players. Twenty-eight university students (12 males, 16 females; aged 17-23) completed a 49-item questionnaire assessing user listening habits and subjective measures of hearing health. Sound level measurements of participants' self-identified typical and 'worst case' volume levels were taken in different classrooms with background sound levels between 43 and 52 dBA. The median frequency and duration of use was 2 h per day, 6.5 days a week. The median sound levels and interquartile ranges (IQR) at typical and 'worst case' volume settings were 71 dBA (IQR=12) and 79 dBA (IQR=9), respectively. When typical sound levels were considered with self-reported duration of daily use, none of the participants surpassed Leq(8) 85 dBA. On the questionnaire, 19 students reported experiencing at least one symptom of possible noise-induced hearing loss. Significant differences in MP3 user listening patterns were found between respondents who had experienced tinnitus and those who had not. The findings add to a growing body of literature that collectively supports a need for further research investigating MP3 player user listening habits in order to assess their potential risk to hearing health.
Evaluation of hearing protection used by police officers in the shooting range.
Guida, Heraldo Lorena; Taxini, Carla Linhares; Gonçalves, Claudia Giglio de Oliveira; Valenti, Vitor Engrácia
2014-01-01
Impact noise is characterized by acoustic energy peaks that last less than a second, at intervals of more than 1s. To quantify the levels of impact noise to which police officers are exposed during activities at the shooting range and to evaluate the attenuation of the hearing protector. Measurements were performed in the shooting range of a military police department. An SV 102 audiodosimeter (Svantek) was used to measure sound pressure levels. Two microphones were used simultaneously: one external and one insertion type; the firearm used was a 0.40 Taurus® rimless pistol. The values obtained with the external microphone were 146 dBC (peak), and a maximum sound level of 129.4 dBC (fast). The results obtained with the insertion microphone were 138.7 dBC (peak), and a maximum sound level of 121.6 dBC (fast). The findings showed high levels of sound pressure in the shooting range, which exceeded the maximum recommended noise (120 dBC), even when measured through the insertion microphone. Therefore, alternatives to improve the performance of hearing protection should be considered. Copyright © 2014 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
En route noise levels from propfan test assessment airplane
NASA Technical Reports Server (NTRS)
Garber, Donald P.; Willshire, William L., Jr.
1994-01-01
The en route noise test was designed to characterize propagation of propfan noise from cruise altitudes to the ground. In-flight measurements of propfan source levels and directional patterns were made by a chase plane flying in formation with the propfan test assessment (PTA) airplane. Ground noise measurements were taken during repeated flights over a distributed microphone array. The microphone array on the ground was used to provide ensemble-averaged estimates of mean flyover noise levels, establish confidence limits for those means, and measure propagation-induced noise variability. Even for identical nominal cruise conditions, peak sound levels for individual overflights varied substantially about the average, particularly when overflights were performed on different days. Large day-to-day variations in peak level measurements appeared to be caused by large day-to-day differences in propagation conditions and tended to obscure small variations arising from operating conditions. A parametric evaluation of the sensitivity of this prediction method to weather measurement and source level uncertainties was also performed. In general, predictions showed good agreement with measurements. However, the method was unable to predict short-term variability of ensemble-averaged data within individual overflights. Although variations in absorption appear to be the dominant factor in variations of peak sound levels recorded on the ground, accurate predictions of those levels require that a complete description of operational conditions be taken into account. The comprehensive and integrated methods presented in this paper have adequately predicted ground-measured sound levels. On average, peak sound levels were predicted within 3 dB for each of the three different cruise conditions.
NASA Technical Reports Server (NTRS)
Chesters, Dennis; Keyser, Dennis A.; Larko, David E.; Uccellini, Louis W.
1987-01-01
An Atmospheric Variability Experiment (AVE) was conducted over the central U.S. in the spring of 1982, collecting radiosonde date to verify mesoscale soundings from the VISSR Atmospheric Sounder (VAS) on the GOES satellite. Previously published VAS/AVE comparisons for the 6 March 1982 case found that the satellite retrievals scarcely detected a low level temperature inversion or a mid-tropospheric cold pool over a special mesoscale radiosonde verification network in north central Texas. The previously published regression and physical retrieval algorithms did not fully utilize VAS' sensitivity to important subsynoptic thermal features. Therefore, the 6 March 1982 case was reprocessed adding two enhancements to the VAS regression retrieval algorithm: (1) the regression matrix was determined using AVE profile data obtained in the region at asynoptic times, and (2) more optimistic signal-to-noise statistical conditioning factors were applied to the VAS temperature sounding channels. The new VAS soundings resolve more of the low level temperature inversion and mid-level cold pool. Most of the improvements stems from the utilization of asynoptic radiosonde observations at NWS sites. This case suggests that VAS regression soundings may require a ground-based asynoptic profiler network to bridge the gap between the synoptic radiosonde network and the high resolution geosynchronous satellite observations during the day.
Behavioral responses of humpback whales (Megaptera novaeangliae) to full-scale ATOC signals.
Frankel, A S; Clark, C W
2000-10-01
Loud (195 dB re 1 microPa at 1 m) 75-Hz signals were broadcast with an ATOC projector to measure ocean temperature. Respiratory and movement behaviors of humpback whales off North Kauai, Hawaii, were examined for potential changes in response to these transmissions and to vessels. Few vessel effects were observed, but there were fewer vessels operating during this study than in previous years. No overt responses to ATOC were observed for received levels of 98-109 dB re 1 microPa. An analysis of covariance, using the no-sound behavioral rate as a covariate to control for interpod variation, found that the distance and time between successive surfacings of humpbacks increased slightly with an increase in estimated received ATOC sound level. These responses are very similar to those observed in response to scaled-amplitude playbacks of ATOC signals [Frankel and Clark, Can. J. Zool. 76, 521-535 (1998)]. These similar results were obtained with different sound projectors, in different years and locations, and at different ranges creating a different sound field. The repeatability of the findings for these two different studies indicates that these effects, while small, are robust. This suggests that at least for the ATOC signal, the received sound level is a good predictor of response.
Effects of Exposure to the Sound from Seismic Airguns on Pallid Sturgeon and Paddlefish
Gross, Jackson A.; Carlson, Thomas J.; Skalski, John; Young, John V.; Hawkins, Anthony D.; Zeddies, David
2016-01-01
This study examined the effects of exposure to a single acoustic pulse from a seismic airgun array on caged endangered pallid sturgeon (Scaphirhynchus albus) and on paddlefish (Polyodon spathula) in Lake Sakakawea (North Dakota, USA). The experiment was designed to detect the onset of physiological responses including minor to mortal injuries. Experimental fish were held in cages as close as 1 to 3 m from the guns where peak negative sound pressure levels (Peak- SPL) reached 231 dB re 1 μPa (205 dB re 1 μPa2·s sound exposure level [SEL]). Additional cages were placed at greater distances in an attempt to develop a dose-response relationship. Treatment and control fish were then monitored for seven days, euthanized, and necropsied to determine injuries. Necropsy results indicated that the probability of delayed mortality associated with pulse pressure following the seven day monitoring period was the same for exposed and control fish of both species. Exposure to a single pulse from a small air gun array (10,160 cm3) was not lethal for pallid sturgeon and paddlefish. However, the risks from exposure to multiple sounds and to sound exposure levels that exceed those reported here remain to be examined. PMID:27505029
Keefe, Douglas H; Feeney, M Patrick; Hunter, Lisa L; Fitzpatrick, Denis F
2017-01-01
Human ear-canal properties of transient acoustic stimuli are contrasted that utilize measured ear-canal pressures in conjunction with measured acoustic pressure reflectance and admittance. These data are referenced to the tip of a probe snugly inserted into the ear canal. Promising procedures to calibrate across frequency include stimuli with controlled levels of incident pressure magnitude, absorbed sound power, and forward pressure magnitude. An equivalent pressure at the eardrum is calculated from these measured data using a transmission-line model of ear-canal acoustics parameterized by acoustically estimated ear-canal area at the probe tip and length between the probe tip and eardrum. Chirp stimuli with constant incident pressure magnitude and constant absorbed sound power across frequency were generated to elicit transient-evoked otoacoustic emissions (TEOAEs), which were measured in normal-hearing adult ears from 0.7 to 8 kHz. TEOAE stimuli had similar peak-to-peak equivalent sound pressure levels across calibration conditions. Frequency-domain TEOAEs were compared using signal level, signal-to-noise ratio (SNR), coherence synchrony modulus (CSM), group delay, and group spread. Time-domain TEOAEs were compared using SNR, CSM, instantaneous frequency and instantaneous bandwidth. Stimuli with constant incident pressure magnitude or constant absorbed sound power across frequency produce generally similar TEOAEs up to 8 kHz.
Effects of Exposure to the Sound from Seismic Airguns on Pallid Sturgeon and Paddlefish.
Popper, Arthur N; Gross, Jackson A; Carlson, Thomas J; Skalski, John; Young, John V; Hawkins, Anthony D; Zeddies, David
2016-01-01
This study examined the effects of exposure to a single acoustic pulse from a seismic airgun array on caged endangered pallid sturgeon (Scaphirhynchus albus) and on paddlefish (Polyodon spathula) in Lake Sakakawea (North Dakota, USA). The experiment was designed to detect the onset of physiological responses including minor to mortal injuries. Experimental fish were held in cages as close as 1 to 3 m from the guns where peak negative sound pressure levels (Peak- SPL) reached 231 dB re 1 μPa (205 dB re 1 μPa2·s sound exposure level [SEL]). Additional cages were placed at greater distances in an attempt to develop a dose-response relationship. Treatment and control fish were then monitored for seven days, euthanized, and necropsied to determine injuries. Necropsy results indicated that the probability of delayed mortality associated with pulse pressure following the seven day monitoring period was the same for exposed and control fish of both species. Exposure to a single pulse from a small air gun array (10,160 cm3) was not lethal for pallid sturgeon and paddlefish. However, the risks from exposure to multiple sounds and to sound exposure levels that exceed those reported here remain to be examined.
Steerable sound transport in a 3D acoustic network
NASA Astrophysics Data System (ADS)
Xia, Bai-Zhan; Jiao, Jun-Rui; Dai, Hong-Qing; Yin, Sheng-Wen; Zheng, Sheng-Jie; Liu, Ting-Ting; Chen, Ning; Yu, De-Jie
2017-10-01
Quasi-lossless and asymmetric sound transports, which are exceedingly desirable in various modern physical systems, are almost always based on nonlinear or angular momentum biasing effects with extremely high power levels and complex modulation schemes. A practical route for the steerable sound transport along any arbitrary acoustic pathway, especially in a three-dimensional (3D) acoustic network, can revolutionize the sound power propagation and the sound communication. Here, we design an acoustic device containing a regular-tetrahedral cavity with four cylindrical waveguides. A smaller regular-tetrahedral solid in this cavity is eccentrically emplaced to break spatial symmetry of the acoustic device. The numerical and experimental results show that the sound power flow can unimpededly transport between two waveguides away from the eccentric solid within a wide frequency range. Based on the quasi-lossless and asymmetric transport characteristic of the single acoustic device, we construct a 3D acoustic network, in which the sound power flow can flexibly propagate along arbitrary sound pathways defined by our acoustic devices with eccentrically emplaced regular-tetrahedral solids.
Acoustic Performance of a Real-Time Three-Dimensional Sound-Reproduction System
NASA Technical Reports Server (NTRS)
Faller, Kenneth J., II; Rizzi, Stephen A.; Aumann, Aric R.
2013-01-01
The Exterior Effects Room (EER) is a 39-seat auditorium at the NASA Langley Research Center and was built to support psychoacoustic studies of aircraft community noise. The EER has a real-time simulation environment which includes a three-dimensional sound-reproduction system. This system requires real-time application of equalization filters to compensate for spectral coloration of the sound reproduction due to installation and room effects. This paper describes the efforts taken to develop the equalization filters for use in the real-time sound-reproduction system and the subsequent analysis of the system s acoustic performance. The acoustic performance of the compensated and uncompensated sound-reproduction system is assessed for its crossover performance, its performance under stationary and dynamic conditions, the maximum spatialized sound pressure level it can produce from a single virtual source, and for the spatial uniformity of a generated sound field. Additionally, application examples are given to illustrate the compensated sound-reproduction system performance using recorded aircraft flyovers
NASA Technical Reports Server (NTRS)
Heffner, R.
2000-01-01
This is the Engineering Test Report, AMSU-A2 METSAT Instrument (S/N 108) Acceptance Level Vibration Test of Dec 1999/Jan 2000 (S/O 784077, OC-454), for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A).
29 CFR 1926.52 - Occupational noise exposure.
Code of Federal Regulations, 2010 CFR
2010-07-01
... protective equipment as required in subpart E, shall be provided and used to reduce sound levels within the... Noise Exposures Duration per day, hours Sound level dBA slow response 8 90 6 92 4 95 3 97 2 100 11/2 102... sample computation showing an application of the formula in paragraph (d)(2)(ii) of this section is as...
29 CFR 1926.52 - Occupational noise exposure.
Code of Federal Regulations, 2011 CFR
2011-07-01
... protective equipment as required in subpart E, shall be provided and used to reduce sound levels within the... Noise Exposures Duration per day, hours Sound level dBA slow response 8 90 6 92 4 95 3 97 2 100 11/2 102... sample computation showing an application of the formula in paragraph (d)(2)(ii) of this section is as...
ERIC Educational Resources Information Center
Apel, Kenn; Lawrence, Jessika
2011-01-01
Purpose: In this study, the authors compared the morphological awareness abilities of children with speech sound disorder (SSD) and children with typical speech skills and examined how morphological awareness ability predicted word-level reading and spelling performance above other known contributors to literacy development. Method: Eighty-eight…
NASA Technical Reports Server (NTRS)
Mehitretter, R.
1996-01-01
Stress analysis of the primary structure of the Meteorological Satellites Project (METSAT) Advanced Microwave Sounding Units-A, A1 Module performed using the Meteorological Operational (METOP) Qualification Level 9.66 grms Random Vibration PSD Spectrum is presented. The random vibration structural margins of safety and natural frequency predictions are summarized.
2013-04-01
a simultaneous time series of marine mammal vocalizations and changing soundscapes (sound levels and spectral shapes) related to surface conditions...mooring (Figures 4, 6, and 7). 1 Figure 4. Seasoanl soundscapes generated... soundscapes in fall (a) and summer (d) show a linear pattern indicating an environment dominated by wind. Sound levels increase linearly as wind
Reducing the ingress of urban noise through natural ventilation openings.
Oldham, D J; de Salis, M H; Sharples, S
2004-01-01
For buildings in busy urban areas affected by high levels of road traffic noise the potential to use natural ventilation can be limited by excessive noise entering through ventilation openings. This paper is concerned with techniques to reduce noise ingress into naturally ventilated buildings while minimizing airflow path resistance. A combined experimental and theoretical approach to the interaction of airflow and sound transmission through ventilators for natural ventilation applications is described. A key element of the investigation has been the development of testing facilities capable of measuring the airflow and sound transmission losses for a range of ventilation noise control strategies. It is demonstrated that a combination of sound reduction mechanisms -- one covering low frequency sound and another covering high frequency sound -- is required to attenuate effectively noise from typical urban sources. A method is proposed for quantifying the acoustic performance of different strategies to enable comparisons and informed decisions to be made leading to the possibility of a design methodology for optimizing the ventilation and acoustic performance of different strategies. The need for employing techniques for combating low frequency sound in tandem with techniques for reducing high frequency sound in reducing the ingress of noise from urban sources such as road traffic to acceptable levels is demonstrated. A technique is proposed for enabling the acoustic and airflow performance of apertures for natural ventilation systems to be designed simultaneously.
Jones, Heath G; Kan, Alan; Litovsky, Ruth Y
2016-01-01
This study examined the effect of microphone placement on the interaural level differences (ILDs) available to bilateral cochlear implant (BiCI) users, and the subsequent effects on horizontal-plane sound localization. Virtual acoustic stimuli for sound localization testing were created individually for eight BiCI users by making acoustic transfer function measurements for microphones placed in the ear (ITE), behind the ear (BTE), and on the shoulders (SHD). The ILDs across source locations were calculated for each placement to analyze their effect on sound localization performance. Sound localization was tested using a repeated-measures, within-participant design for the three microphone placements. The ITE microphone placement provided significantly larger ILDs compared to BTE and SHD placements, which correlated with overall localization errors. However, differences in localization errors across the microphone conditions were small. The BTE microphones worn by many BiCI users in everyday life do not capture the full range of acoustic ILDs available, and also reduce the change in cue magnitudes for sound sources across the horizontal plane. Acute testing with an ITE placement reduced sound localization errors along the horizontal plane compared to the other placements in some patients. Larger improvements may be observed if patients had more experience with the new ILD cues provided by an ITE placement.
A geospatial model of ambient sound pressure levels in the contiguous United States.
Mennitt, Daniel; Sherrill, Kirk; Fristrup, Kurt
2014-05-01
This paper presents a model that predicts measured sound pressure levels using geospatial features such as topography, climate, hydrology, and anthropogenic activity. The model utilizes random forest, a tree-based machine learning algorithm, which does not incorporate a priori knowledge of source characteristics or propagation mechanics. The response data encompasses 270 000 h of acoustical measurements from 190 sites located in National Parks across the contiguous United States. The explanatory variables were derived from national geospatial data layers and cross validation procedures were used to evaluate model performance and identify variables with predictive power. Using the model, the effects of individual explanatory variables on sound pressure level were isolated and quantified to reveal systematic trends across environmental gradients. Model performance varies by the acoustical metric of interest; the seasonal L50 can be predicted with a median absolute deviation of approximately 3 dB. The primary application for this model is to generalize point measurements to maps expressing spatial variation in ambient sound levels. An example of this mapping capability is presented for Zion National Park and Cedar Breaks National Monument in southwestern Utah.
Underwater temporary threshold shift in pinnipeds: effects of noise level and duration.
Kastak, David; Southall, Brandon L; Schusterman, Ronald J; Kastak, Colleen Reichmuth
2005-11-01
Behavioral psychophysical techniques were used to evaluate the residual effects of underwater noise on the hearing sensitivity of three pinnipeds: a California sea lion (Zalophus californianus), a harbor seal (Phoca vitulina), and a northern elephant seal (Mirounga angustirostris). Temporary threshold shift (TTS), defined as the difference between auditory thresholds obtained before and after noise exposure, was assessed. The subjects were exposed to octave-band noise centered at 2500 Hz at two sound pressure levels: 80 and 95 dB SL (re: auditory threshold at 2500 Hz). Noise exposure durations were 22, 25, and 50 min. Threshold shifts were assessed at 2500 and 3530 Hz. Mean threshold shifts ranged from 2.9-12.2 dB. Full recovery of auditory sensitivity occurred within 24 h of noise exposure. Control sequences, comprising sham noise exposures, did not result in significant mean threshold shifts for any subject. Threshold shift magnitudes increased with increasing noise sound exposure level (SEL) for two of the three subjects. The results underscore the importance of including sound exposure metrics (incorporating sound pressure level and exposure duration) in order to fully assess the effects of noise on marine mammal hearing.
Fligor, Brian J; Cox, L Clarke
2004-12-01
To measure the sound levels generated by the headphones of commercially available portable compact disc players and provide hearing healthcare providers with safety guidelines based on a theoretical noise dose model. Using a Knowles Electronics Manikin for Acoustical Research and a personal computer, output levels across volume control settings were recorded from headphones driven by a standard signal (white noise) and compared with output levels from music samples of eight different genres. Many commercially available models from different manufacturers were investigated. Several different styles of headphones (insert, supra-aural, vertical, and circumaural) were used to determine if style of headphone influenced output level. Free-field equivalent sound pressure levels measured at maximum volume control setting ranged from 91 dBA to 121 dBA. Output levels varied across manufacturers and style of headphone, although generally the smaller the headphone, the higher the sound level for a given volume control setting. Specifically, in one manufacturer, insert earphones increased output level 7-9 dB, relative to the output from stock headphones included in the purchase of the CD player. In a few headphone-CD player combinations, peak sound pressure levels exceeded 130 dB SPL. Based on measured sound pressure levels across systems and the noise dose model recommended by National Institute for Occupational Safety and Health for protecting the occupational worker, a maximum permissible noise dose would typically be reached within 1 hr of listening with the volume control set to 70% of maximum gain using supra-aural headphones. Using headphones that resulted in boosting the output level (e.g., insert earphones used in this study) would significantly decrease the maximum safe volume control setting; this effect was unpredictable from one manufacturer to another. In the interest of providing a straightforward recommendation that should protect the hearing of the majority of consumers, reasonable guidelines would include a recommendation to limit headphone use to 1 hr or less per day if using supra-aural style headphones at a gain control setting of 60% of maximum.
He, Wenxuan; Porsov, Edward; Kemp, David; Nuttall, Alfred L.; Ren, Tianying
2012-01-01
Background It is commonly assumed that the cochlear microphonic potential (CM) recorded from the round window (RW) is generated at the cochlear base. Based on this assumption, the low-frequency RW CM has been measured for evaluating the integrity of mechanoelectrical transduction of outer hair cells at the cochlear base and for studying sound propagation inside the cochlea. However, the group delay and the origin of the low-frequency RW CM have not been demonstrated experimentally. Methodology/Principal Findings This study quantified the intra-cochlear group delay of the RW CM by measuring RW CM and vibrations at the stapes and basilar membrane in gerbils. At low sound levels, the RW CM showed a significant group delay and a nonlinear growth at frequencies below 2 kHz. However, at high sound levels or at frequencies above 2 kHz, the RW CM magnitude increased proportionally with sound pressure, and the CM phase in respect to the stapes showed no significant group delay. After the local application of tetrodotoxin the RW CM below 2 kHz became linear and showed a negligible group delay. In contrast to RW CM phase, the BM vibration measured at location ∼2.5 mm from the base showed high sensitivity, sharp tuning, and nonlinearity with a frequency-dependent group delay. At low or intermediate sound levels, low-frequency RW CMs were suppressed by an additional tone near the probe-tone frequency while, at high sound levels, they were partially suppressed only at high frequencies. Conclusions/Significance We conclude that the group delay of the RW CM provides no temporal information on the wave propagation inside the cochlea, and that significant group delay of low-frequency CMs results from the auditory nerve neurophonic potential. Suppression data demonstrate that the generation site of the low-frequency RW CM shifts from apex to base as the probe-tone level increases. PMID:22470560
Active localization of virtual sounds
NASA Technical Reports Server (NTRS)
Loomis, Jack M.; Hebert, C.; Cicinelli, J. G.
1991-01-01
We describe a virtual sound display built around a 12 MHz 80286 microcomputer and special purpose analog hardware. The display implements most of the primary cues for sound localization in the ear-level plane. Static information about direction is conveyed by interaural time differences and, for frequencies above 1800 Hz, by head sound shadow (interaural intensity differences) and pinna sound shadow. Static information about distance is conveyed by variation in sound pressure (first power law) for all frequencies, by additional attenuation in the higher frequencies (simulating atmospheric absorption), and by the proportion of direct to reverberant sound. When the user actively locomotes, the changing angular position of the source occasioned by head rotations provides further information about direction and the changing angular velocity produced by head translations (motion parallax) provides further information about distance. Judging both from informal observations by users and from objective data obtained in an experiment on homing to virtual and real sounds, we conclude that simple displays such as this are effective in creating the perception of external sounds to which subjects can home with accuracy and ease.
Exploring positive hospital ward soundscape interventions.
Mackrill, J; Jennings, P; Cain, R
2014-11-01
Sound is often considered as a negative aspect of an environment that needs mitigating, particularly in hospitals. It is worthwhile however, to consider how subjective responses to hospital sounds can be made more positive. The authors identified natural sound, steady state sound and written sound source information as having the potential to do this. Listening evaluations were conducted with 24 participants who rated their emotional (Relaxation) and cognitive (Interest and Understanding) response to a variety of hospital ward soundscape clips across these three interventions. A repeated measures ANOVA revealed that the 'Relaxation' response was significantly affected (n(2) = 0.05, p = 0.001) by the interventions with natural sound producing a 10.1% more positive response. Most interestingly, written sound source information produced a 4.7% positive change in response. The authors conclude that exploring different ways to improve the sounds of a hospital offers subjective benefits that move beyond sound level reduction. This is an area for future work to focus upon in an effort to achieve more positively experienced hospital soundscapes and environments. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.