Evaluation of the impact of noise metrics on tiltrotor aircraft design
NASA Technical Reports Server (NTRS)
Sternfeld, H.; Spencer, R.; Ziegenbein, P.
1995-01-01
A subjective noise evaluation was conducted in which the test participants evaluated the annoyance of simulated sounds representative of future civil tiltrotor aircraft. The subjective responses were correlated with the noise metrics of A-weighted sound pressure level, overall sound pressure level, and perceived level. The results indicated that correlation between subjective response and A-weighted sound pressure level is considerably enhanced by combining it in a multiple regression with overall sound pressure level. As a single metric, perceived level correlated better than A-weighted sound pressure level due to greater emphasis on low frequency noise components. This latter finding was especially true for indoor noise where the mid and high frequency noise components are attenuated by typical building structure. Using the results of the subjective noise evaluation, the impact on tiltrotor aircraft design was also evaluated. While A-weighted sound pressure level can be reduced by reduction in tip speed, an increase in number of rotor blades is required to achieve significant reduction of low frequency noise as measured by overall sound pressure level. Additional research, however, is required to achieve comparable reductions in impulsive noise due to blade-vortex interaction, and also to achieve reduction in broad band noise.
24 CFR 51.106 - Implementation.
Code of Federal Regulations, 2010 CFR
2010-04-01
... day-night average sound level data are not available may be evaluated from NEF or CNEL analyses using.... The day-night average sound level may be estimated from the design hour L10 or Leq values by the.... The Department of Defense uses day-night average sound level based on C-weighted sound level...
Twardella, Dorothee; Wellhoefer, Andrea; Brix, Jutta; Fromme, Hermann
2008-01-01
While no legal rules or regulations exist in Germany, voluntary measures were introduced to achieve a reduction of sound pressure levels in discotheques to levels below 100 dB(A). To evaluate the current levels in Bavarian discotheques and to find out whether these voluntary measures ensured compliance with the recommended limits, sound pressure levels were measured in 20 Bavarian discotheques between 11 p.m. and 2 a.m. With respect to the equivalent continuous A-weighted sound pressure level for each 30-minute period (L Aeq,30min ), only 4/20 discotheques remained below the limit of 100 dB(A) in all time periods. Ten discotheques had sound pressure levels below 100 dB(A) for the total measurement period (L Aeq,180min ). None of the evaluated factors (weekday, size, estimated age of attendees, the use of voluntary measures such as participation of disc jockeys in a tutorial, or the availability of a sound level meter for the DJs) was significantly associated with the maximal L Aeq, 30min . Thus, the introduction of voluntary measures was not sufficient to ensure compliance with the recommended limits of sound pressure levels.
Statistical Analysis for Subjective and Objective Evaluations of Dental Drill Sounds.
Yamada, Tomomi; Kuwano, Sonoko; Ebisu, Shigeyuki; Hayashi, Mikako
2016-01-01
The sound produced by a dental air turbine handpiece (dental drill) can markedly influence the sound environment in a dental clinic. Indeed, many patients report that the sound of a dental drill elicits an unpleasant feeling. Although several manufacturers have attempted to reduce the sound pressure levels produced by dental drills during idling based on ISO 14457, the sound emitted by such drills under active drilling conditions may negatively influence the dental clinic sound environment. The physical metrics related to the unpleasant impressions associated with dental drill sounds have not been determined. In the present study, psychological measurements of dental drill sounds were conducted with the aim of facilitating improvement of the sound environment at dental clinics. Specifically, we examined the impressions elicited by the sounds of 12 types of dental drills in idling and drilling conditions using a semantic differential. The analysis revealed that the impressions of dental drill sounds varied considerably between idling and drilling conditions and among the examined drills. This finding suggests that measuring the sound of a dental drill in idling conditions alone may be insufficient for evaluating the effects of the sound. We related the results of the psychological evaluations to those of measurements of the physical metrics of equivalent continuous A-weighted sound pressure levels (LAeq) and sharpness. Factor analysis indicated that impressions of the dental drill sounds consisted of two factors: "metallic and unpleasant" and "powerful". LAeq had a strong relationship with "powerful impression", calculated sharpness was positively related to "metallic impression", and "unpleasant impression" was predicted by the combination of both LAeq and calculated sharpness. The present analyses indicate that, in addition to a reduction in sound pressure level, refining the frequency components of dental drill sounds is important for creating a comfortable sound environment in dental clinics.
Transfer of knowledge from sound quality measurement to noise impact evaluation
NASA Astrophysics Data System (ADS)
Genuit, Klaus
2004-05-01
It is well known that the measurement and analysis of sound quality requires a complex procedure with consideration of the physical, psychoacoustical and psychological aspects of sound. Sound quality cannot be described only by a simple value based on A-weighted sound pressure level measurements. The A-weighted sound pressure level is sufficient to predict the probabilty that the human ear could be damaged by sound but the A-weighted level is not the correct descriptor for the annoyance of a complex sound situation given by several different sound events at different and especially moving positions (soundscape). On the one side, the consideration of the spectral distribution and the temporal pattern (psychoacoustics) is requested and, on the other side, the subjective attitude with respect to the sound situation, the expectation and experience of the people (psychology) have to be included in context with the complete noise impact evaluation. This paper describes applications of the newest methods of sound quality measurements-as it is well introduced at the car manufacturers-based on artifical head recordings and signal processing comparable to the human hearing used in noisy environments like community/traffic noise.
Statistical Analysis for Subjective and Objective Evaluations of Dental Drill Sounds
Yamada, Tomomi; Kuwano, Sonoko; Ebisu, Shigeyuki; Hayashi, Mikako
2016-01-01
The sound produced by a dental air turbine handpiece (dental drill) can markedly influence the sound environment in a dental clinic. Indeed, many patients report that the sound of a dental drill elicits an unpleasant feeling. Although several manufacturers have attempted to reduce the sound pressure levels produced by dental drills during idling based on ISO 14457, the sound emitted by such drills under active drilling conditions may negatively influence the dental clinic sound environment. The physical metrics related to the unpleasant impressions associated with dental drill sounds have not been determined. In the present study, psychological measurements of dental drill sounds were conducted with the aim of facilitating improvement of the sound environment at dental clinics. Specifically, we examined the impressions elicited by the sounds of 12 types of dental drills in idling and drilling conditions using a semantic differential. The analysis revealed that the impressions of dental drill sounds varied considerably between idling and drilling conditions and among the examined drills. This finding suggests that measuring the sound of a dental drill in idling conditions alone may be insufficient for evaluating the effects of the sound. We related the results of the psychological evaluations to those of measurements of the physical metrics of equivalent continuous A-weighted sound pressure levels (LAeq) and sharpness. Factor analysis indicated that impressions of the dental drill sounds consisted of two factors: “metallic and unpleasant” and “powerful”. LAeq had a strong relationship with “powerful impression”, calculated sharpness was positively related to “metallic impression”, and “unpleasant impression” was predicted by the combination of both LAeq and calculated sharpness. The present analyses indicate that, in addition to a reduction in sound pressure level, refining the frequency components of dental drill sounds is important for creating a comfortable sound environment in dental clinics. PMID:27462903
1987-09-01
stethoscope . Auscultation in respiratory medicine, however, has advanced slowly since Laennec established auscultation of lung sounds as a means of... stethoscope and the ear have limitations in their use as instruments for the evaluation of respiratory sounds. Respiratory sounds have a wide spectrum...Amplification, Rectification and Level-shft ing Stage ... 11 Respiratory Sound Circuitry ....... .................. ... 11 Sound Sensor
A national project to evaluate and reduce high sound pressure levels from music.
Ryberg, Johanna Bengtsson
2009-01-01
The highest recommended sound pressure levels for leisure sounds (music) in Sweden are 100 dB LAeq and 115 dB LAFmax for adults, and 97 dB LAeq and 110 dB LAFmax where children under the age of 13 have access. For arrangements intended for children, levels should be consistently less than 90 dB LAeq. In 2005, a national project was carried out with the aim of improving environments with high sound pressure levels from music, such as concert halls, restaurants, and cinemas. The project covered both live and recorded music. Of Sweden's 290 municipalities, 134 took part in the project, and 93 of these carried out sound measurements. Four hundred and seventy one establishments were investigated, 24% of which exceeded the highest recommended sound pressure levels for leisure sounds in Sweden. Of festival and concert events, 42% exceeded the recommended levels. Those who visit music events/establishments thus run a relatively high risk of exposure to harmful sound levels. Continued supervision in this field is therefore crucial.
Noise in the operating rooms of Greek hospitals.
Tsiou, Chrisoula; Efthymiatos, Gerasimos; Katostaras, Theophanis
2008-02-01
This study is an evaluation of the problem of noise pollution in operating rooms. The high sound pressure level of noise in the operating theatre has a negative impact on communication between operating room personnel. The research took place at nine Greek public hospitals with more than 400 beds. The objective evaluation consisted of sound pressure level measurements in terms of L(eq), as well as peak sound pressure levels in recordings during 43 surgeries in order to identify sources of noise. The subjective evaluation consisted of a questionnaire answered by 684 operating room personnel. The views of operating room personnel were studied using Pearson's X(2) Test and Fisher's Exact Test (SPSS Version 10.00), a t-test comparison was made of mean sound pressure levels, and the relationship of measurement duration and sound pressure level was examined using linear regression analysis (SPSS Version 13.00). The sound pressure levels of noise per operation and the sources of noise varied. The maximum measured level of noise during the main procedure of an operation was measured at L(eq)=71.9 dB(A), L(1)=84.7 dB(A), L(10)=76.2 dB(A), and L(99)=56.7 dB(A). The hospital building, machinery, tools, and people in the operating room were the main noise factors. In order to eliminate excess noise in the operating room it may be necessary to adopt a multidisciplinary approach. An improvement in environment (background noise levels), the implementation of effective standards, and the focusing of the surgical team on noise matters are considered necessary changes.
Threshold for onset of injury in Chinook salmon from exposure to impulsive pile driving sounds.
Halvorsen, Michele B; Casper, Brandon M; Woodley, Christa M; Carlson, Thomas J; Popper, Arthur N
2012-01-01
The risk of effects to fishes and other aquatic life from impulsive sound produced by activities such as pile driving and seismic exploration is increasing throughout the world, particularly with the increased exploitation of oceans for energy production. At the same time, there are few data that provide insight into the effects of these sounds on fishes. The goal of this study was to provide quantitative data to define the levels of impulsive sound that could result in the onset of barotrauma to fish. A High Intensity Controlled Impedance Fluid filled wave Tube was developed that enabled laboratory simulation of high-energy impulsive sound that were characteristic of aquatic far-field, plane-wave acoustic conditions. The sounds used were based upon the impulsive sounds generated by an impact hammer striking a steel shell pile. Neutrally buoyant juvenile Chinook salmon (Oncorhynchus tshawytscha) were exposed to impulsive sounds and subsequently evaluated for barotrauma injuries. Observed injuries ranged from mild hematomas at the lowest sound exposure levels to organ hemorrhage at the highest sound exposure levels. Frequency of observed injuries were used to compute a biological response weighted index (RWI) to evaluate the physiological impact of injuries at the different exposure levels. As single strike and cumulative sound exposure levels (SEL(ss), SEL(cum) respectively) increased, RWI values increased. Based on the results, tissue damage associated with adverse physiological costs occurred when the RWI was greater than 2. In terms of sound exposure levels a RWI of 2 was achieved for 1920 strikes by 177 dB re 1 µPa(2)⋅s SEL(ss) yielding a SEL(cum) of 210 dB re 1 µPa(2)⋅s, and for 960 strikes by 180 dB re 1 µPa(2)⋅s SEL(ss) yielding a SEL(cum) of 210 dB re 1 µPa(2)⋅s. These metrics define thresholds for onset of injury in juvenile Chinook salmon.
Threshold for Onset of Injury in Chinook Salmon from Exposure to Impulsive Pile Driving Sounds
Halvorsen, Michele B.; Casper, Brandon M.; Woodley, Christa M.; Carlson, Thomas J.; Popper, Arthur N.
2012-01-01
The risk of effects to fishes and other aquatic life from impulsive sound produced by activities such as pile driving and seismic exploration is increasing throughout the world, particularly with the increased exploitation of oceans for energy production. At the same time, there are few data that provide insight into the effects of these sounds on fishes. The goal of this study was to provide quantitative data to define the levels of impulsive sound that could result in the onset of barotrauma to fish. A High Intensity Controlled Impedance Fluid filled wave Tube was developed that enabled laboratory simulation of high-energy impulsive sound that were characteristic of aquatic far-field, plane-wave acoustic conditions. The sounds used were based upon the impulsive sounds generated by an impact hammer striking a steel shell pile. Neutrally buoyant juvenile Chinook salmon (Oncorhynchus tshawytscha) were exposed to impulsive sounds and subsequently evaluated for barotrauma injuries. Observed injuries ranged from mild hematomas at the lowest sound exposure levels to organ hemorrhage at the highest sound exposure levels. Frequency of observed injuries were used to compute a biological response weighted index (RWI) to evaluate the physiological impact of injuries at the different exposure levels. As single strike and cumulative sound exposure levels (SELss, SELcum respectively) increased, RWI values increased. Based on the results, tissue damage associated with adverse physiological costs occurred when the RWI was greater than 2. In terms of sound exposure levels a RWI of 2 was achieved for 1920 strikes by 177 dB re 1 µPa2⋅s SELss yielding a SELcum of 210 dB re 1 µPa2⋅s, and for 960 strikes by 180 dB re 1 µPa2⋅s SELss yielding a SELcum of 210 dB re 1 µPa2⋅s. These metrics define thresholds for onset of injury in juvenile Chinook salmon. PMID:22745695
Torija, Antonio J; Ruiz, Diego P; Ramos-Ridao, A F
2013-07-01
A subjective and physical categorization of an ambient sound is the first step to evaluate the soundscape and provides a basis for designing or adapting this ambient sound to match people's expectations. For this reason, the main goal of this work is to develop a categorization and differentiation analysis of soundscapes on the basis of acoustical and perceptual variables. A hierarchical cluster analysis, using 15 semantic-differential attributes and acoustical descriptors to include an equivalent sound-pressure level, maximum-minimum sound-pressure level, impulsiveness of the sound-pressure level, sound-pressure level time course, and spectral composition, was conducted to classify soundscapes into different typologies. This analysis identified 15 different soundscape typologies. Furthermore, based on a discriminant analysis the acoustical descriptors, the crest factor (impulsiveness of the sound-pressure level), and the sound level at 125 Hz were found to be the acoustical variables with the highest impact in the differentiation of the recognized types of soundscapes. Finally, to determine how the different soundscape typologies differed from each other, both subjectively and acoustically, a study was performed.
Christiaens, Véronique; De Bruyn, Hugo; Thevissen, Eric; Koole, Sebastiaan; Dierens, Melissa; Cosyn, Jan
2018-01-01
The accuracy of analogue and especially digital intra-oral radiography in assessing interdental bone level needs further documentation. The aim of this study was to compare clinical and radiographic bone level assessment to intra-surgical bone level registration (1) and to identify the clinical variables rendering interdental bone level assessment inaccurate (2). The study sample included 49 interdental sites in 17 periodontitis patients. Evaluation methods included vertical relative probing attachment level (RAL-V), analogue and digital intra-oral radiography and bone sounding without and with flap elevation. The latter was considered the true bone level. Five examiners evaluated all radiographs. Significant underestimation of the true bone level was observed for all evaluation methods pointing to 2.7 mm on average for analogue radiography, 2.5 mm for digital radiography, 1.8 mm for RAL-V and 0.6 mm for bone sounding without flap elevation (p < 0.001). Radiographic underestimation of the true bone level was higher in the (pre)molar region (p ≤ 0.047) and increased with defect depth (p < 0.001). Variation between clinicians was huge (range analogue radiography 2.2-3.2 mm; range digital radiography 2.1-3.0 mm). All evaluation methods significantly underestimated the true bone level. Bone sounding was most accurate, whereas intra-oral radiographs were least accurate. Deep periodontal defects in the (pre)molar region were most underrated by intra-oral radiography. Bone sounding had the highest accuracy in assessing interdental bone level.
Guo, Bin; Huang, Jing; Guo, Xin-biao
2015-06-18
To evaluate the preventive effects of sound insulation windows on traffic noise. Indoor noise levels of the residential rooms (on both the North 4th ring road side and the campus side) with closed sound insulation windows were measured using the sound level meter, and comparisons with the simultaneously measured outdoor noise levels were made. In addition, differences of indoor noise levels between rooms with closed sound insulation windows and open sound insulation windows were also compared. The average outdoor noise levels of the North 4th ring road was higher than 70 dB(A), which exceeded the limitation stated in the "Environmental Quality Standard for Noise" (GB 3096-2008) in our country. However, with the sound insulation windows closed, the indoor noise levels reduced significantly to the level under 35 dB(A) (P<0.05), which complied with the indoor noise level standards in our country. The closed or open states of the sound insulation windows had significant influence on the indoor noise levels (P<0.05). Compared with the open state of the sound insulation window, when the sound insulation windows were closed, the indoor noise levels reduced 18.8 dB(A) and 8.3 dB(A) in residential rooms facing North 4th ring road side and campus side, respectively. The results indicated that installation of insulation windows had significant noise reduction effects on street residential buildings especially on the rooms facing major traffic roads. Installation of the sound insulation windows has significant preventive effects on indoor noise in the street residential building.
Designing sound and visual components for enhancement of urban soundscapes.
Hong, Joo Young; Jeon, Jin Yong
2013-09-01
The aim of this study is to investigate the effect of audio-visual components on environmental quality to improve soundscape. Natural sounds with road traffic noise and visual components in urban streets were evaluated through laboratory experiments. Waterfall and stream water sounds, as well as bird sounds, were selected to enhance the soundscape. Sixteen photomontages of a streetscape were constructed in combination with two types of water features and three types of vegetation which were chosen as positive visual components. The experiments consisted of audio-only, visual-only, and audio-visual conditions. The preferences and environmental qualities of the stimuli were evaluated by a numerical scale and 12 pairs of adjectives, respectively. The results showed that bird sounds were the most preferred among the natural sounds, while the sound of falling water was found to degrade the soundscape quality when the road traffic noise level was high. The visual effects of vegetation on aesthetic preference were significant, but those of water features relatively small. It was revealed that the perceptual dimensions of the environment were different from the noise levels. Particularly, the acoustic comfort factor related to soundscape quality considerably influenced preference for the overall environment at a higher level of road traffic noise.
Analysis of sound pressure levels emitted by children's toys.
Sleifer, Pricila; Gonçalves, Maiara Santos; Tomasi, Marinês; Gomes, Erissandra
2013-06-01
To verify the levels of sound pressure emitted by non-certified children's toys. Cross-sectional study of sound toys available at popular retail stores of the so-called informal sector. Electronic, mechanical, and musical toys were analyzed. The measurement of each product was carried out by an acoustic engineer in an acoustically isolated booth, by a decibel meter. To obtain the sound parameters of intensity and frequency, the toys were set to produce sounds at a distance of 10 and 50cm from the researcher's ear. The intensity of sound pressure [dB(A)] and the frequency in hertz (Hz) were measured. 48 toys were evaluated. The mean sound pressure 10cm from the ear was 102±10 dB(A), and at 50cm, 94±8 dB(A), with p<0.05. The level of sound pressure emitted by the majority of toys was above 85dB(A). The frequency ranged from 413 to 6,635Hz, with 56.3% of toys emitting frequency higher than 2,000Hz. The majority of toys assessed in this research emitted a high level of sound pressure.
Perceptual assessment of quality of urban soundscapes with combined noise sources and water sounds.
Jeon, Jin Yong; Lee, Pyoung Jik; You, Jin; Kang, Jian
2010-03-01
In this study, urban soundscapes containing combined noise sources were evaluated through field surveys and laboratory experiments. The effect of water sounds on masking urban noises was then examined in order to enhance the soundscape perception. Field surveys in 16 urban spaces were conducted through soundwalking to evaluate the annoyance of combined noise sources. Synthesis curves were derived for the relationships between noise levels and the percentage of highly annoyed (%HA) and the percentage of annoyed (%A) for the combined noise sources. Qualitative analysis was also made using semantic scales for evaluating the quality of the soundscape, and it was shown that the perception of acoustic comfort and loudness was strongly related to the annoyance. A laboratory auditory experiment was then conducted in order to quantify the total annoyance caused by road traffic noise and four types of construction noise. It was shown that the annoyance ratings were related to the types of construction noise in combination with road traffic noise and the level of the road traffic noise. Finally, water sounds were determined to be the best sounds to use for enhancing the urban soundscape. The level of the water sounds should be similar to or not less than 3 dB below the level of the urban noises.
Minimizing noise in fiberglass aquaculture tanks: Noise reduction potential of various retrofits
Davidson, J.; Frankel, A.S.; Ellison, W.T.; Summerfelt, S.; Popper, A.N.; Mazik, P.; Bebak, J.
2007-01-01
Equipment used in intensive aquaculture systems, such as pumps and blowers can produce underwater sound levels and frequencies within the range of fish hearing. The impacts of underwater noise on fish are not well known, but limited research suggests that subjecting fish to noise could result in impairment of the auditory system, reduced growth rates, and increased stress. Consequently, reducing sound in fish tanks could result in advantages for cultured species and increased productivity for the aquaculture industry. The objective of this study was to evaluate the noise reduction potential of various retrofits to fiberglass fish culture tanks. The following structural changes were applied to tanks to reduce underwater noise: (1) inlet piping was suspended to avoid contact with the tank, (2) effluent piping was disconnected from a common drain line, (3) effluent piping was insulated beneath tanks, and (4) tanks were elevated on cement blocks and seated on insulated padding. Four combinations of the aforementioned structural changes were evaluated in duplicate and two tanks were left unchanged as controls. Control tanks had sound levels of 120.6 dB re 1 ??Pa. Each retrofit contributed to a reduction of underwater sound. As structural changes were combined, a cumulative reduction in sound level was observed. Tanks designed with a combination of retrofits had sound levels of 108.6 dB re 1 ??Pa, a four-fold reduction in sound pressure level. Sound frequency spectra indicated that the greatest sound reductions occurred between 2 and 100 Hz and demonstrated that nearby pumps and blowers created tonal frequencies that were transmitted into the tanks. The tank modifications used during this study were simple and inexpensive and could be applied to existing systems or considered when designing aquaculture facilities. ?? 2007 Elsevier B.V. All rights reserved.
Sound propagation elements in evaluation of en route noise of advanced turbofan aircraft
NASA Technical Reports Server (NTRS)
Sutherland, Louis C.; Wesler, John
1990-01-01
Cruise noise from an advanced turboprop aircraft is reviewed on the basis of available wind tunnel data to estimate the aircraft noise signature at the source. Available analytical models are used to evaluate the sound levels at the ground. The analysis allows reasonable estimates to be made of the community noise levels that might be generated during cruise by such aircraft, provides the basis for preliminary comparisons with available data on noise of existing aircraft during climb and helps to identify the dominant elements of the sound propagation models applicable to this situation.
The influence of company identity on the perception of vehicle sounds.
Humphreys, Louise; Giudice, Sebastiano; Jennings, Paul; Cain, Rebecca; Song, Wookeun; Dunne, Garry
2011-04-01
In order to determine how the interior of a car should sound, automotive manufacturers often rely on obtaining data from individual evaluations of vehicle sounds. Company identity could play a role in these appraisals, particularly when individuals are comparing cars from opposite ends of the performance spectrum. This research addressed the question: does company identity influence the evaluation of automotive sounds belonging to cars of a similar performance level and from the same market segment? Participants listened to car sounds from two competing manufacturers, together with control sounds. Before listening to each sound, participants were presented with the correct company identity for that sound, the incorrect identity or were given no information about the identity of the sound. The results showed that company identity did not influence appraisals of high performance cars belonging to different manufacturers. These results have positive implications for methodologies employed to capture the perceptions of individuals. STATEMENT OF RELEVANCE: A challenge in automotive design is to set appropriate targets for vehicle sounds, relying on understanding subjective reactions of individuals to such sounds. This paper assesses the role of company identity in influencing these subjective reactions and will guide sound evaluation studies, in which the manufacturer is often apparent.
Calibration of Clinical Audio Recording and Analysis Systems for Sound Intensity Measurement.
Maryn, Youri; Zarowski, Andrzej
2015-11-01
Sound intensity is an important acoustic feature of voice/speech signals. Yet recordings are performed with different microphone, amplifier, and computer configurations, and it is therefore crucial to calibrate sound intensity measures of clinical audio recording and analysis systems on the basis of output of a sound-level meter. This study was designed to evaluate feasibility, validity, and accuracy of calibration methods, including audiometric speech noise signals and human voice signals under typical speech conditions. Calibration consisted of 3 comparisons between data from 29 measurement microphone-and-computer systems and data from the sound-level meter: signal-specific comparison with audiometric speech noise at 5 levels, signal-specific comparison with natural voice at 3 levels, and cross-signal comparison with natural voice at 3 levels. Intensity measures from recording systems were then linearly converted into calibrated data on the basis of these comparisons, and validity and accuracy of calibrated sound intensity were investigated. Very strong correlations and quasisimilarity were found between calibrated data and sound-level meter data across calibration methods and recording systems. Calibration of clinical sound intensity measures according to this method is feasible, valid, accurate, and representative for a heterogeneous set of microphones and data acquisition systems in real-life circumstances with distinct noise contexts.
Evaluation of noise pollution level in the operating rooms of hospitals: A study in Iran.
Giv, Masoumeh Dorri; Sani, Karim Ghazikhanlou; Alizadeh, Majid; Valinejadi, Ali; Majdabadi, Hesamedin Askari
2017-06-01
Noise pollution in the operating rooms is one of the remaining challenges. Both patients and physicians are exposed to different sound levels during the operative cases, many of which can last for hours. This study aims to evaluate the noise pollution in the operating rooms during different surgical procedures. In this cross-sectional study, sound level in the operating rooms of Hamadan University-affiliated hospitals (totally 10) in Iran during different surgical procedures was measured using B&K sound meter. The gathered data were compared with national and international standards. Statistical analysis was performed using descriptive statistics and one-way ANOVA, t -test, and Pearson's correlation test. Noise pollution level at majority of surgical procedures is higher than national and international documented standards. The highest level of noise pollution is related to orthopedic procedures, and the lowest one related to laparoscopic and heart surgery procedures. The highest and lowest registered sound level during the operation was 93 and 55 dB, respectively. Sound level generated by equipments (69 ± 4.1 dB), trolley movement (66 ± 2.3 dB), and personnel conversations (64 ± 3.9 dB) are the main sources of noise. The noise pollution of operating rooms are higher than available standards. The procedure needs to be corrected for achieving the proper conditions.
An Inexpensive Group FM Amplification System for the Classroom.
ERIC Educational Resources Information Center
Worner, William A.
1988-01-01
An inexpensive FM amplification system was developed to enhance auditory learning in classrooms for the hearing impaired. Evaluation indicated that the system equalizes the sound pressure level throughout the room, with the increased sound pressure level falling in the range of 70 to 73 decibels. (Author/DB)
Psychophysiological acoustics of indoor sound due to traffic noise during sleep
NASA Astrophysics Data System (ADS)
Tulen, J. H. M.; Kumar, A.; Jurriëns, A. A.
1986-10-01
The relation between the physical characteristics of sound and an individual's perception of its as annoyance is complex and unclear. Sleep disturbance by sound is manifested in the physiological responses to the sound stimuli and the quality of sleep perceived in the morning. Both may result in deterioration of functioning during wakefulness. Therefore, psychophysiological responses to noise during sleep should be studied for the evaluation of the efficacy of sound insulation. Nocturnal sleep and indoor sound level were recorded in the homes of 12 subjects living along a highway with high traffic density. Double glazing sound insulation was used to create two experimental conditions: low insulation and high insulation. Twenty recordings were made per subject, ten recordings in each condition. During the nights with low insulation the quality of sleep was so low that both performance and mood were negatively affected. The enhancement of sound insulation was not effective enough to increase the restorative effects of sleep. The transient and peaky characteristics of traffic sound were also found to result in non-adaptive physiological responses during sleep. Sound insulation did have an effect on noise peak characteristics such as peak level, peak duration and slope. However, the number of sound peaks were found to be the same in both conditions. The relation of these sound peaks detected in the indoor recorded sound level signal to characteristics of passing vehicles was established, indicating that the sound peaks causing the psychophysiological disturbances during sleep were generated by the passing vehicles. Evidence is presented to show that the reduction in sound level is not a good measure of efficacy of sound insulation. The parameters of the sound peaks, as described in this paper, are a better representation of psychophysiological efficacy of sound insulation.
[Acoustical parameters of toys].
Harazin, Barbara
2010-01-01
Toys play an important role in the development of the sight and hearing concentration in children. They also support the development of manipulation, gently influence a child and excite its emotional activities. A lot of toys emit various sounds. The aim of the study was to assess sound levels produced by sound-emitting toys used by young children. Acoustical parameters of noise were evaluated for 16 sound-emitting plastic toys in laboratory conditions. The noise level was recorded at four different distances, 10, 20, 25 and 30 cm, from the toy. Measurements of A-weighted sound pressure levels and noise levels in octave band in the frequency range from 31.5 Hz to 16 kHz were performed at each distance. Taking into consideration the highest equivalent A-weighted sound levels produced by tested toys, they can be divided into four groups: below 70 dB (6 toys), from 70 to 74 dB (4 toys), from 75 to 84 dB (3 toys) and from 85 to 94 dB (3 toys). The majority of toys (81%) emitted dominant sound levels in octave band at the frequency range from 2 kHz to 4 kHz. Sound-emitting toys produce the highest acoustic energy at the frequency range of the highest susceptibility of the auditory system. Noise levels produced by some toys can be dangerous to children's hearing.
Vibro-Acoustic Analysis of an Aircraft Maintenance Dock
1992-08-01
evaluated. This evaluation resulted in a table of allowable number of cycles of operation to produce the same impact on the facility as the original...for 18 Gage Galvanized Steel Walls of HV Ducts 209 H13 Summary of Calculated Vibration Response Parameters at Base of HV 217 H 14 Engine Power Level...The reverberant sound field due to the acoustic energy remaining within the AMD after the first reflection of the direct sound. The direct sound field
Spacecraft Internal Acoustic Environment Modeling
NASA Technical Reports Server (NTRS)
Chu, SShao-sheng R.; Allen, Christopher S.
2009-01-01
Acoustic modeling can be used to identify key noise sources, determine/analyze sub-allocated requirements, keep track of the accumulation of minor noise sources, and to predict vehicle noise levels at various stages in vehicle development, first with estimates of noise sources, later with experimental data. In FY09, the physical mockup developed in FY08, with interior geometric shape similar to Orion CM (Crew Module) IML (Interior Mode Line), was used to validate SEA (Statistical Energy Analysis) acoustic model development with realistic ventilation fan sources. The sound power levels of these sources were unknown a priori, as opposed to previous studies that RSS (Reference Sound Source) with known sound power level was used. The modeling results were evaluated based on comparisons to measurements of sound pressure levels over a wide frequency range, including the frequency range where SEA gives good results. Sound intensity measurement was performed over a rectangular-shaped grid system enclosing the ventilation fan source. Sound intensities were measured at the top, front, back, right, and left surfaces of the and system. Sound intensity at the bottom surface was not measured, but sound blocking material was placed tinder the bottom surface to reflect most of the incident sound energy back to the remaining measured surfaces. Integrating measured sound intensities over measured surfaces renders estimated sound power of the source. The reverberation time T6o of the mockup interior had been modified to match reverberation levels of ISS US Lab interior for speech frequency bands, i.e., 0.5k, 1k, 2k, 4 kHz, by attaching appropriately sized Thinsulate sound absorption material to the interior wall of the mockup. Sound absorption of Thinsulate was modeled in three methods: Sabine equation with measured mockup interior reverberation time T60, layup model based on past impedance tube testing, and layup model plus air absorption correction. The evaluation/validation was carried out by acquiring octave band microphone data simultaneously at ten fixed locations throughout the mockup. SPLs (Sound Pressure Levels) predicted by our SEA model match well with measurements for our CM mockup, with a more complicated shape. Additionally in FY09, background NC noise (Noise Criterion) simulation and MRT (Modified Rhyme Test) were developed and performed in the mockup to determine the maximum noise level in CM habitable volume for fair crew voice communications. Numerous demonstrations of simulated noise environment in the mockup and associated SIL (Speech Interference Level) via MRT were performed for various communities, including members from NASA and Orion prime-/sub-contractors. Also, a new HSIR (Human-Systems Integration Requirement) for limiting pre- and post-landing SIL was proposed.
The softest sound levels of the human voice in normal subjects.
Šrámková, Hana; Granqvist, Svante; Herbst, Christian T; Švec, Jan G
2015-01-01
Accurate measurement of the softest sound levels of phonation presents technical and methodological challenges. This study aimed at (1) reliably obtaining normative data on sustained softest sound levels for the vowel [a:] at comfortable pitch; (2) comparing the results for different frequency and time weighting methods; and (3) refining the Union of European Phoniatricians' recommendation on allowed background noise levels for scientific and equipment manufacturers' purposes. Eighty healthy untrained participants (40 females, 40 males) were investigated in quiet rooms using a head-mounted microphone and a sound level meter at 30 cm distance. The one-second-equivalent sound levels were more stable and more representative for evaluating the softest sustained phonations than the fast-time-weighted levels. At 30 cm, these levels were in the range of 48-61 dB(C)/41-53 dB(A) for females and 49 - 64 dB(C)/35-53 dB(A) for males (5% to 95% quantile range). These ranges may serve as reference data in evaluating vocal normality. In order to reach a signal-to-noise ratio of at least 10 dB for more than 95% of the normal population, the background noise should be below 25 dB(A) and 38 dB(C), respectively, for the softest phonation measurements at 30 cm distance. For the A-weighting, this is 15 dB lower than the previously recommended value.
The subjective evaluation of noise from light aircraft
NASA Technical Reports Server (NTRS)
Shepherd, K. P.
1976-01-01
A study was conducted in which subjects evaluated the sounds of a light aircraft and a motorcycle. Particular emphasis was placed on examining the duration of the sounds. Thirty subjects gave annoyance ratings to a total of 50 sounds, with peak levels between 65 and 85dB(A). It was found that aircraft and motorcycles have differing optimum duration corrections. The conventional duration correction used in the calculation of EPNL is far from being the optimum for light aircraft.
Almadhoob, Abdulraoof; Ohlsson, Arne
2015-01-30
Infants in the neonatal intensive care unit (NICU) are subjected to stress, including sound of high intensity. The sound environment in the NICU is louder than most home or office environments and contains disturbing noises of short duration and at irregular intervals. There are competing auditory signals that frequently challenge preterm infants, staff and parents. The sound levels in NICUs often exceed the maximum acceptable level of 45 decibels (dB), recommended by the American Academy of Pediatrics. Hearing impairment is diagnosed in 2% to 10% of preterm infants versus 0.1% of the general paediatric population. Noise may cause apnoea, hypoxaemia, alternation in oxygen saturation, and increased oxygen consumption secondary to elevated heart and respiratory rates and may, therefore, decrease the amount of calories available for growth. Elevated levels of speech are needed to overcome the noisy environment in the NICU, thereby increasing the negative impacts on staff, newborns, and their families. High noise levels are associated with an increased rate of errors and accidents, leading to decreased performance among staff. The aim of interventions included in this review is to reduce sound levels to 45 dB or less. This can be achieved by lowering the sound levels in an entire unit, treating the infant in a section of a NICU, in a 'private' room, or in incubators in which the sound levels are controlled, or reducing the sound levels that reaches the individual infant by using earmuffs or earplugs. By lowering the sound levels that reach the neonate, the resulting stress on the cardiovascular, respiratory, neurological, and endocrine systems can be diminished, thereby promoting growth and reducing adverse neonatal outcomes. Primary objectiveTo determine the effects of sound reduction on growth and long-term neurodevelopmental outcomes of neonates. Secondary objectives1. To evaluate the effects of sound reduction on short-term medical outcomes (bronchopulmonary dysplasia, intraventricular haemorrhage, periventricular leukomalacia, retinopathy of prematurity).2. To evaluate the effects of sound reduction on sleep patterns at three months of age.3. To evaluate the effects of sound reduction on staff performance.4. To evaluate the effects of sound reduction in the neonatal intensive care unit (NICU) on parents' satisfaction with the care. We searched the Cochrane Central Register of Controlled Trials (The Cochrane Library), MEDLINE, EMBASE, CINAHL, abstracts from scientific meetings, clinical trials registries (clinicaltrials.gov; controlled-trials.com; and who.int/ictrp), Pediatric Academic Societies Annual meetings 2000 to 2014 (Abstracts2View(TM)), reference lists of identified trials, and reviews to November 2014. Preterm infants (< 32 weeks' postmenstrual age (PMA) or < 1500 g birth weight) cared for in the resuscitation area, during transport, or once admitted to a NICU or a stepdown unit. We performed data collection and analyses according to the Cochrane Neonatal Review Group. One small, high quality study assessing the effects of silicone earplugs versus no earplugs qualified for inclusion. The original inclusion criteria in our protocol stipulated an age of < 48 hours at the time of initiating sound reduction. We made a deviation from our protocol and included this study in which some infants would have been > 48 hours old. There was no significant difference in weight at 34 weeks postmenstrual age (PMA): mean difference (MD) 111 g (95% confidence interval (CI) -151 to 374 g) (n = 23). There was no significant difference in weight at 18 to 22 months corrected age between the groups: MD 0.31 kg, 95% CI -1.53 to 2.16 kg (n = 14). There was a significant difference in Mental Developmental Index (Bayley II) favouring the silicone earplugs group at 18 to 22 months corrected age: MD 14.00, 95% CI 3.13 to 24.87 (n = 12), but not for Psychomotor Development Index (Bayley II) at 18 to 22 months corrected age: MD -2.16, 95% CI -18.44 to 14.12 (n =12). To date, only 34 infants have been enrolled in a randomised controlled trial (RCT) testing the effectiveness of reducing sound levels that reach the infants' ears in the NICU. Based on the small sample size of this single trial, we cannot make any recommendations for clinical practice. Larger, well designed, conducted and reported trials are needed.
NASA Technical Reports Server (NTRS)
Brooks, T. F.
1977-01-01
The Kirchhoff integral formulation is evaluated for its effectiveness in quantitatively predicting the sound radiated from an oscillating airfoil whose chord length is comparable with the acoustic wavelength. A rigid airfoil section was oscillated at samll amplitude in a medium at rest to produce the sound field. Simultaneous amplitude and phase measurements were made of surface pressure and surface velocity distributions and the acoustic free field. Measured surface pressure and motion are used in applying the theory, and airfoil thickness and contour are taken into account. The result was that the theory overpredicted the sound pressure level by 2 to 5, depending on direction. Differences are also noted in the sound field phase behavior.
Prieve, Kurt; Rice, Amanda; Raynor, Peter C
2017-08-01
The aims of this study were to evaluate sound levels produced by compressed air guns in research and development (R&D) environments, replace conventional air gun models with advanced noise-reducing air nozzles, and measure changes in sound levels to assess the effectiveness of the advanced nozzles as engineering controls for noise. Ten different R&D manufacturing areas that used compressed air guns were identified and included in the study. A-weighted sound level and Z-weighted octave band measurements were taken simultaneously using a single instrument. In each area, three sets of measurements, each lasting for 20 sec, were taken 1 m away and perpendicular to the air stream of the conventional air gun while a worker simulated typical air gun work use. Two different advanced noise-reducing air nozzles were then installed. Sound level and octave band data were collected for each of these nozzles using the same methods as for the original air guns. Both of the advanced nozzles provided sound level reductions of about 7 dBA, on average. The highest noise reductions measured were 17.2 dBA for one model and 17.7 dBA for the other. In two areas, the advanced nozzles yielded no sound level reduction, or they produced small increases in sound level. The octave band data showed strong similarities in sound level among all air gun nozzles within the 10-1,000 Hz frequency range. However, the advanced air nozzles generally had lower noise contributions in the 1,000-20,000 Hz range. The observed decreases at these higher frequencies caused the overall sound level reductions that were measured. Installing new advanced noise-reducing air nozzles can provide large sound level reductions in comparison to existing conventional nozzles, which has direct benefit for hearing conservation efforts.
Popov, Vladimir V; Supin, Alexander Ya; Rozhnov, Viatcheslav V; Nechaev, Dmitry I; Sysueva, Evgenia V
2014-05-15
The influence of fatiguing sound level and duration on post-exposure temporary threshold shift (TTS) was investigated in two beluga whales (Delphinapterus leucas). The fatiguing sound was half-octave noise with a center frequency of 22.5 kHz. TTS was measured at a test frequency of 32 kHz. Thresholds were measured by recording rhythmic evoked potentials (the envelope following response) to a test series of short (eight cycles) tone pips with a pip rate of 1000 s(-1). TTS increased approximately proportionally to the dB measure of both sound pressure (sound pressure level, SPL) and duration of the fatiguing noise, as a product of these two variables. In particular, when the noise parameters varied in a manner that maintained the product of squared sound pressure and time (sound exposure level, SEL, which is equivalent to the overall noise energy) at a constant level, TTS was not constant. Keeping SEL constant, the highest TTS appeared at an intermediate ratio of SPL to sound duration and decreased at both higher and lower ratios. Multiplication (SPL multiplied by log duration) better described the experimental data than an equal-energy (equal SEL) model. The use of SEL as a sole universal metric may result in an implausible assessment of the impact of a fatiguing sound on hearing thresholds in odontocetes, including under-evaluation of potential risks. © 2014. Published by The Company of Biologists Ltd.
Ultrasound visual feedback treatment and practice variability for residual speech sound errors
Preston, Jonathan L.; McCabe, Patricia; Rivera-Campos, Ahmed; Whittle, Jessica L.; Landry, Erik; Maas, Edwin
2014-01-01
Purpose The goals were to (1) test the efficacy of a motor-learning based treatment that includes ultrasound visual feedback for individuals with residual speech sound errors, and (2) explore whether the addition of prosodic cueing facilitates speech sound learning. Method A multiple baseline single subject design was used, replicated across 8 participants. For each participant, one sound context was treated with ultrasound plus prosodic cueing for 7 sessions, and another sound context was treated with ultrasound but without prosodic cueing for 7 sessions. Sessions included ultrasound visual feedback as well as non-ultrasound treatment. Word-level probes assessing untreated words were used to evaluate retention and generalization. Results For most participants, increases in accuracy of target sound contexts at the word level were observed with the treatment program regardless of whether prosodic cueing was included. Generalization between onset singletons and clusters was observed, as well as generalization to sentence-level accuracy. There was evidence of retention during post-treatment probes, including at a two-month follow-up. Conclusions A motor-based treatment program that includes ultrasound visual feedback can facilitate learning of speech sounds in individuals with residual speech sound errors. PMID:25087938
Sato, Shin-ichi; You, Jin; Jeon, Jin Yong
2007-07-01
Psychoacoustical and autocorrelation function (ACF) parameters were employed to describe the temporal fluctuations of refrigerator noise during starting, transition into/from the stationary phase and termination of operation. The temporal fluctuations of refrigerator noise include a click at start-up, followed by a rapid increase in volume, a change of pitch, and termination of the operation. Subjective evaluations of the noise of 24 different refrigerators were conducted in a real living environment. The relationship between objective measures and perceived noisiness was examined by multiple regression analysis. Sound quality indices were developed based on psychoacoustical and ACF parameters. The psychoacoustical parameters found to be important for evaluating noisiness in the stationary phase were loudness and roughness. The relationship between noisiness and ACF parameters shows that sound energy and its fluctuations are important for evaluating noisiness. Also, refrigerator sounds that had a fluctuation of pitch were rated as more annoying. The tolerance level for the starting phase of refrigerator noise was found to be 33 dBA, which is the level where 65% of the participants in the subjective tests were satisfied.
DOT National Transportation Integrated Search
1975-11-01
The appendix to the preceding volume presents the data for the subject diesel engine noise study, including an engine sound power level analysis and sound spectrums showing the effect of intake and exhaust restrictions.
Comprehensive measures of sound exposures in cinemas using smart phones.
Huth, Markus E; Popelka, Gerald R; Blevins, Nikolas H
2014-01-01
Sensorineural hearing loss from sound overexposure has a considerable prevalence. Identification of sound hazards is crucial, as prevention, due to a lack of definitive therapies, is the sole alternative to hearing aids. One subjectively loud, yet little studied, potential sound hazard is movie theaters. This study uses smart phones to evaluate their applicability as a widely available, validated sound pressure level (SPL) meter. Therefore, this study measures sound levels in movie theaters to determine whether sound levels exceed safe occupational noise exposure limits and whether sound levels in movie theaters differ as a function of movie, movie theater, presentation time, and seat location within the theater. Six smart phones with an SPL meter software application were calibrated with a precision SPL meter and validated as an SPL meter. Additionally, three different smart phone generations were measured in comparison to an integrating SPL meter. Two different movies, an action movie and a children's movie, were measured six times each in 10 different venues (n = 117). To maximize representativeness, movies were selected focusing on large release productions with probable high attendance. Movie theaters were selected in the San Francisco, CA, area based on whether they screened both chosen movies and to represent the largest variety of theater proprietors. Measurements were analyzed in regard to differences between theaters, location within the theater, movie, as well as presentation time and day as indirect indicator of film attendance. The smart phone measurements demonstrated high accuracy and reliability. Overall, sound levels in movie theaters do not exceed safe exposure limits by occupational standards. Sound levels vary significantly across theaters and demonstrated statistically significant higher sound levels and exposures in the action movie compared to the children's movie. Sound levels decrease with distance from the screen. However, no influence on time of day or day of the week as indirect indicator of film attendance could be found. Calibrated smart phones with an appropriate software application as used in this study can be utilized as a validated SPL meter. Because of the wide availability, smart phones in combination with the software application can provide high quantity recreational sound exposure measurements, which can facilitate the identification of potential noise hazards. Sound levels in movie theaters decrease with distance to the screen, but do not exceed safe occupational noise exposure limits. Additionally, there are significant differences in sound levels across movie theaters and movies, but not in presentation time.
NASA Technical Reports Server (NTRS)
Wolfson, N.; Thomasell, A.; Alperson, Z.; Brodrick, H.; Chang, J. T.; Gruber, A.; Ohring, G.
1984-01-01
The impact of introducing satellite temperature sounding data on a numerical weather prediction model of a national weather service is evaluated. A dry five level, primitive equation model which covers most of the Northern Hemisphere, is used for these experiments. Series of parallel forecast runs out to 48 hours are made with three different sets of initial conditions: (1) NOSAT runs, only conventional surface and upper air observations are used; (2) SAT runs, satellite soundings are added to the conventional data over oceanic regions and North Africa; and (3) ALLSAT runs, the conventional upper air observations are replaced by satellite soundings over the entire model domain. The impact on the forecasts is evaluated by three verification methods: the RMS errors in sea level pressure forecasts, systematic errors in sea level pressure forecasts, and errors in subjective forecasts of significant weather elements for a selected portion of the model domain. For the relatively short range of the present forecasts, the major beneficial impacts on the sea level pressure forecasts are found precisely in those areas where the satellite sounding are inserted and where conventional upper air observations are sparse. The RMS and systematic errors are reduced in these regions. The subjective forecasts of significant weather elements are improved with the use of the satellite data. It is found that the ALLSAT forecasts are of a quality comparable to the SAR forecasts.
Masalski, Marcin; Kipiński, Lech; Grysiński, Tomasz; Kręcicki, Tomasz
2016-05-30
Hearing tests carried out in home setting by means of mobile devices require previous calibration of the reference sound level. Mobile devices with bundled headphones create a possibility of applying the predefined level for a particular model as an alternative to calibrating each device separately. The objective of this study was to determine the reference sound level for sets composed of a mobile device and bundled headphones. Reference sound levels for Android-based mobile devices were determined using an open access mobile phone app by means of biological calibration, that is, in relation to the normal-hearing threshold. The examinations were conducted in 2 groups: an uncontrolled and a controlled one. In the uncontrolled group, the fully automated self-measurements were carried out in home conditions by 18- to 35-year-old subjects, without prior hearing problems, recruited online. Calibration was conducted as a preliminary step in preparation for further examination. In the controlled group, audiologist-assisted examinations were performed in a sound booth, on normal-hearing subjects verified through pure-tone audiometry, recruited offline from among the workers and patients of the clinic. In both the groups, the reference sound levels were determined on a subject's mobile device using the Bekesy audiometry. The reference sound levels were compared between the groups. Intramodel and intermodel analyses were carried out as well. In the uncontrolled group, 8988 calibrations were conducted on 8620 different devices representing 2040 models. In the controlled group, 158 calibrations (test and retest) were conducted on 79 devices representing 50 models. Result analysis was performed for 10 most frequently used models in both the groups. The difference in reference sound levels between uncontrolled and controlled groups was 1.50 dB (SD 4.42). The mean SD of the reference sound level determined for devices within the same model was 4.03 dB (95% CI 3.93-4.11). Statistically significant differences were found across models. Reference sound levels determined in the uncontrolled group are comparable to the values obtained in the controlled group. This validates the use of biological calibration in the uncontrolled group for determining the predefined reference sound level for new devices. Moreover, due to a relatively small deviation of the reference sound level for devices of the same model, it is feasible to conduct hearing screening on devices calibrated with the predefined reference sound level.
Evaluation of hearing protection used by police officers in the shooting range.
Guida, Heraldo Lorena; Taxini, Carla Linhares; Gonçalves, Claudia Giglio de Oliveira; Valenti, Vitor Engrácia
2014-01-01
Impact noise is characterized by acoustic energy peaks that last less than a second, at intervals of more than 1s. To quantify the levels of impact noise to which police officers are exposed during activities at the shooting range and to evaluate the attenuation of the hearing protector. Measurements were performed in the shooting range of a military police department. An SV 102 audiodosimeter (Svantek) was used to measure sound pressure levels. Two microphones were used simultaneously: one external and one insertion type; the firearm used was a 0.40 Taurus® rimless pistol. The values obtained with the external microphone were 146 dBC (peak), and a maximum sound level of 129.4 dBC (fast). The results obtained with the insertion microphone were 138.7 dBC (peak), and a maximum sound level of 121.6 dBC (fast). The findings showed high levels of sound pressure in the shooting range, which exceeded the maximum recommended noise (120 dBC), even when measured through the insertion microphone. Therefore, alternatives to improve the performance of hearing protection should be considered. Copyright © 2014 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Acceptability of VTOL aircraft noise determined by absolute subjective testing
NASA Technical Reports Server (NTRS)
Sternfeld, H., Jr.; Hinterkeuser, E. G.; Hackman, R. B.; Davis, J.
1972-01-01
A program was conducted during which test subjects evaluated the simulated sounds of a helicopter, a tilt wing aircraft, and a 15 second, 90 PNdB (indoors) turbojet aircraft used as reference. Over 20,000 evaluations were made while the test subjects were engaged in work and leisure activities. The effects of level, exposure time, distance and aircraft design on subjective acceptability were evaluated. Some of the important conclusions are: (1) To be judged equal in annoyance to the reference jet sound, the helicopter and tilt wing sounds must be 4 to 5 PNdB lower when lasting 15 seconds in duration. (2) To be judged significantly more acceptable than the reference jet sound, the helicopter sound must be 10 PNdB lower when lasting 15 seconds in duration. (3) To be judged significantly more acceptable than the reference jet sound, the tilt wing sound must be 12 PNdB lower when lasting 15 seconds in duration. (4) The relative effect of changing the duration of a sound upon its subjectively rated annoyance diminishes with increasing duration. It varies from 2 PNdB per doubling of duration for intervals of 15 to 30 seconds, to 0.75 PNdB per doubling of duration for intervals of 120 to 240 seconds.
Stanley, Jenni A; Van Parijs, Sofie M; Hatch, Leila T
2017-11-07
Stellwagen Bank National Marine Sanctuary is located in Massachusetts Bay off the densely populated northeast coast of the United States; subsequently, the marine inhabitants of the area are exposed to elevated levels of anthropogenic underwater sound, particularly due to commercial shipping. The current study investigated the alteration of estimated effective communication spaces at three spawning locations for populations of the commercially and ecologically important fishes, Atlantic cod (Gadus morhua) and haddock (Melanogrammus aeglefinus). Both the ambient sound pressure levels and the estimated effective vocalization radii, estimated through spherical spreading models, fluctuated dramatically during the three-month recording periods. Increases in sound pressure level appeared to be largely driven by large vessel activity, and accordingly exhibited a significant positive correlation with the number of Automatic Identification System tracked vessels at the two of the three sites. The near constant high levels of low frequency sound and consequential reduction in the communication space observed at these recording sites during times of high vocalization activity raises significant concerns that communication between conspecifics may be compromised during critical biological periods. This study takes the first steps in evaluating these animals' communication spaces and alteration of these spaces due to anthropogenic underwater sound.
An evaluation of Space Shuttle STS-2 payload bay acoustic data and comparison with predictions
NASA Technical Reports Server (NTRS)
Wilby, J. F.; Piersol, A. G.; Wilby, E. G.
1982-01-01
Space average sound pressure levels computed from measurements at 18 locations in the payload bay of the Space Shuttle orbiter vehicle during the STS-2 launch were compared with predicted levels obtained using the PACES computer program. The comparisons were performed over the frequency range 12.5 Hz to 1000 Hz, since the test data at higher frequencies are contaminated by instrumentation background noise. In general the PACES computer program tends to overpredict the space average sound levels in the payload bay, although the magnitude of the discrepancy is usually small. Furthermore the discrepancy depends to some extent on the manner in which the payload is modeled analytically, and the method used to determine the "measured' space average sound pressure levels. Thus the difference between predicted and measured sound levels, averaged over the 20 one third octave bands from 12.5 Hz to 1000 Hz, varies from 1 dB to 3.5 dB.
Lobarinas, Edward; Scott, Ryan; Spankovich, Christopher; Le Prell, Colleen G
2016-01-01
Firearm discharges produce hazardous levels of impulse noise that can lead to permanent hearing loss. In the present study, we evaluated the effects of suppression, ammunition, and barrel length on AR-15 rifles. Sound levels were measured left/right of a user's head, and 1-m left of the muzzle, per MIL-STD-1474-D, under both unsuppressed and suppressed conditions. Nine commercially available AR-15 rifles and 14 suppressors were used. Suppressors significantly decreased peak dB SPL at the 1-m location and the left ear location. However, under most rifle/ammunition conditions, levels remained above 140 dB peak SPL near a user's right ear. In a subset of conditions, subsonic ammunition produced values near or below 140 dB peak SPL. Overall suppression ranged from 7-32 dB across conditions. These data indicate that (1) suppressors reduce discharge levels to 140 dB peak SPL or below in only a subset of AR-15 conditions, (2) shorter barrel length and use of muzzle brake devices can substantially increase exposure level for the user, and (3) there are significant left/right ear sound pressure differences under suppressed conditions as a function of the AR-15 direct impingement design that must be considered during sound measurements to fully evaluate overall efficacy.
Maccariello, Carolina Elisabetta Martins; Franzini de Souza, Carla Caroline; Morena, Laura; Dias, Daniel Penteado Martins; Medeiros, Magda Alves de
2018-03-15
Sound stimuli such as fireworks, firearms, and claps of thunder have been used as a stress reactivity model for dogs. Acupuncture has been widely used to treat and prevent physiological and behavioural disorders induced by stress. Our study aims to evaluate the effects of acupuncture on cardiac autonomic modulation (heart rate variability - HRV), behavioural (reactivity) and endocrine (cortisol levels) responses in dogs exposed to sounds of thunder. Twenty-four laboratory beagles (12 males and 12 females, 1-6years old) with no history of phobia to thunder were subjected to a sound stimulus that consisted of a standardized recording of thunder over a 150s period with a maximum intensity of 103-104dB. Before the sound, the dogs underwent a 20-minute session of needle insertion at acupuncture points Yintang, GV20, HT7, PC6 and ST36 (ACUP), in non-points (NP) or left undisturbed (CTL). Cardiac intervals were recorded using a frequency meter (RS 800cx, Polar, Kempele, Finland) to evaluate the HRV, and the data were later analysed using CardioSeries v2.4.1 software. Acupuncture (ACUP) changed the sympathovagal balance with a shift towards parasympathetic modulation, reducing the prompt sound-induced increase in LF/HF (low frequency/high frequency) ratio and in the power of the LF band of the cardiac interval spectrum, and decreased the power of the HF band of the cardiac interval spectrum (p<0.05); however there was no change in the heart rate. Acupuncture reduced the behavioural response induced by sounds of thunder (when all behavioural parameters were considered together) and the behaviours hiding, restlessness, bolting and running around (when the parameters were analysed separately (p<0.05). There were no changes in cortisol levels due to the sound stimulus or acupuncture. Our results demonstrate that a session of acupuncture prior to sound stimulus can reduce cardiac autonomic and behavioural responses, without changing cortisol levels in beagles. Copyright © 2018 Elsevier Inc. All rights reserved.
Impulsivity of Noise due to Single Lightweight Vehicles Transit on Transverse Rumble Strip
NASA Astrophysics Data System (ADS)
Darus, N.; Haron, Z.; Yahya, K.; Halil, M. H. Abd; Norudin, W. M. A.; Othman, M. H.; Hezmi, M. A.
2018-03-01
Transverse Rumble Strips (TRS) acts as safety device that alert inattentive drivers from potential dangers. However, the noise produced due to TRS was reported as noise annoyance among the nearby residents lived adjacent to roadways. Thus, this paper investigates the impulsivity characteristic of noise due to single lightweight vehicles transit on TRS. The objectives of this study are to determine the increase of sound level and to evaluate the impulsivity of noise. Two TRS profiles namely middle overlapped (MO) and middle layer overlapped (MLO) were selected. Three types of single lightweight vehicles which include hatchback, sedan and multipurpose (MPV) were tested at speed of 30, 50 and 70km/h. The sound level was measured using sound level meter (SLM). Noise indices such as LAeq, LAIeqT, LAImax, LAFmax and LASmax were obtained from the measurement. This study considered the differences of LAImax - LAFmax > 2dBA, LAFmax - LAeq ≥ 10dBA, LAIeqT - LAeq ≥ 2dBA and LAImax - LASmax > 6dBA to evaluate the impulsivity of noise. It was found that TRS increased the sound level by at most of 6dBA. Furthermore, all single lightweight vehicles transit on TRS show significant impulsive characteristic. These results proved that TRS produce significant impact to the nearby residents.
Simulation of prenatal maternal sounds in NICU incubators: a pilot safety and feasibility study.
Panagiotidis, John; Lahav, Amir
2010-10-01
This pilot study evaluated the safety and feasibility of an innovative audio system for transmitting maternal sounds to NICU incubators. A sample of biological sounds, consisting of voice and heartbeat, were recorded from a mother of a premature infant admitted to our unit. The maternal sounds were then played back inside an unoccupied incubator via a specialized audio system originated and compiled in our lab. We performed a series of evaluations to determine the safety and feasibility of using this system in NICU incubators. The proposed audio system was found to be safe and feasible, meeting criteria for humidity and temperature resistance, as well as for safe noise levels. Simulation of maternal sounds using this system seems achievable and applicable and received local support from medical staff. Further research and technology developments are needed to optimize the design of the NICU incubators to preserve the acoustic environment of the womb.
Optimum employment of satellite indirect soundings as numerical model input
NASA Technical Reports Server (NTRS)
Horn, L. H.; Derber, J. C.; Koehler, T. L.; Schmidt, B. D.
1981-01-01
The characteristics of satellite-derived temperature soundings that would significantly affect their use as input for numerical weather prediction models were examined. Independent evaluations of satellite soundings were emphasized to better define error characteristics. Results of a Nimbus-6 sounding study reveal an underestimation of the strength of synoptic scale troughs and ridges, and associated gradients in isobaric height and temperature fields. The most significant errors occurred near the Earth's surface and the tropopause. Soundings from the TIROS-N and NOAA-6 satellites were also evaluated. Results again showed an underestimation of upper level trough amplitudes leading to weaker thermal gradient depictions in satellite-only fields. These errors show a definite correlation to the synoptic flow patterns. In a satellite-only analysis used to initialize a numerical model forecast, it was found that these synoptically correlated errors were retained in the forecast sequence.
Effects of HearFones on speaking and singing voice quality.
Laukkanen, Anne-Maria; Mickelson, Nils Peter; Laitala, Marja; Syrjä, Tiina; Salo, Arla; Sihvo, Marketta
2004-12-01
HearFones (HF) have been designed to enhance auditory feedback during phonation. This study investigated the effects of HF (1) on sound perceivable by the subject, (2) on voice quality in reading and singing, and (3) on voice production in speech and singing at the same pitch and sound level. Test 1: Text reading was recorded with two identical microphones in the ears of a subject. One ear was covered with HF, and the other was free. Four subjects attended this test. Tests 2 and 3: A reading sample was recorded from 13 subjects and a song from 12 subjects without and with HF on. Test 4: Six females repeated [pa:p:a] in speaking and singing modes without and with HF on same pitch and sound level. Long-term average spectra were made (Tests 1-3), and formant frequencies, fundamental frequency, and sound level were measured (Tests 2 and 3). Subglottic pressure was estimated from oral pressure in [p], and simultaneously electroglottography (EGG) was registered during voicing on [a:] (Test 4). Voice quality in speech and singing was evaluated by three professional voice trainers (Tests 2-4). HF seemed to enhance sound perceivable at the whole range studied (0-8 kHz), with the greatest enhancement (up to ca 25 dB) being at 1-3 kHz and at 4-7 kHz. The subjects tended to decrease loudness with HF (when sound level was not being monitored). In more than half of the cases, voice quality was evaluated "less strained" and "better controlled" with HF. When pitch and loudness were constant, no clear differences were heard but closed quotient of the EGG signal was higher and the signal more skewed, suggesting a better glottal closure and/or diminished activity of the thyroarytenoid muscle.
Noise in early childhood education institutions.
Bitar, Mariangela Lopes; Calaço, Luiz Ferreira; Simões-Zenari, Marcia
2018-01-01
High sound pressure levels have been observed in schools, and its interference in the health of children and teachers it was taken to analyze these levels in childhood education centers serving children aged zero to six years, investigate the staff's perceptions concerning noise exposure and identify the auditory conditions of these workers and the occurrence of diseases. The study was conducted in ten institutions employing 320 workers. Sound pressure levels were measured according to the technical norms; employees completed a questionnaire on the perception of noise and underwent auditory evaluation. There was high sound pressure level and differences between institutions, situations and places. Most employees are considered exposed to noise with attention and concentration difficulties, anxiety and headache. About 30% of employees had bilateral sensorineural hearing loss in specific frequency. The sound pressure levels found can affect children's learning and the health of all. The employees also perceived elevated levels of noise and indicated some possible negative aspects in their work routine. Actions to improve the acoustic comfort in these institutions will be discussed with the management teams.
Murphy, William J; Flamme, Gregory A; Campbell, Adam R; Zechmann, Edward L; Tasko, Stephen M; Lankford, James E; Meinke, Deanna K; Finan, Donald S; Stewart, Michael
2018-02-01
This research assessed the reduction of peak levels, equivalent energy and sound power of firearm suppressors. The first study evaluated the effect of three suppressors at four microphone positions around four firearms. The second study assessed the suppressor-related reduction of sound power with a 3 m hemispherical microphone array for two firearms. The suppressors reduced exposures at the ear between 17 and 24 dB peak sound pressure level and reduced the 8 h equivalent A-weighted energy between 9 and 21 dB depending upon the firearm and ammunition. Noise reductions observed for the instructor's position about a metre behind the shooter were between 20 and 28 dB peak sound pressure level and between 11 and 26 dB L Aeq,8h . Firearm suppressors reduced the measured sound power levels between 2 and 23 dB. Sound power reductions were greater for the low-velocity ammunition than for the same firearms fired with high-velocity ammunition due to the effect of N-waves produced by a supersonic bullet. Firearm suppressors may reduce noise exposure, and the cumulative exposures of suppressed firearms can still present a significant hearing risk. Therefore, firearm users should always wear hearing protection whenever target shooting or hunting.
Mackrill, J B; Jennings, P A; Cain, R
2013-01-01
Work on the perception of urban soundscapes has generated a number of perceptual models which are proposed as tools to test and evaluate soundscape interventions. However, despite the excessive sound levels and noise within hospital environments, perceptual models have not been developed for these spaces. To address this, a two-stage approach was developed by the authors to create such a model. First, semantics were obtained from listening evaluations which captured the feelings of individuals from hearing hospital sounds. Then, 30 participants rated a range of sound clips representative of a ward soundscape based on these semantics. Principal component analysis extracted a two-dimensional space representing an emotional-cognitive response. The framework enables soundscape interventions to be tested which may improve the perception of these hospital environments.
Airframe noise prediction evaluation
NASA Technical Reports Server (NTRS)
Yamamoto, Kingo J.; Donelson, Michael J.; Huang, Shumei C.; Joshi, Mahendra C.
1995-01-01
The objective of this study is to evaluate the accuracy and adequacy of current airframe noise prediction methods using available airframe noise measurements from tests of a narrow body transport (DC-9) and a wide body transport (DC-10) in addition to scale model test data. General features of the airframe noise from these aircraft and models are outlined. The results of the assessment of two airframe prediction methods, Fink's and Munson's methods, against flight test data of these aircraft and scale model wind tunnel test data are presented. These methods were extensively evaluated against measured data from several configurations including clean, slat deployed, landing gear-deployed, flap deployed, and landing configurations of both DC-9 and DC-10. They were also assessed against a limited number of configurations of scale models. The evaluation was conducted in terms of overall sound pressure level (OASPL), tone corrected perceived noise level (PNLT), and one-third-octave band sound pressure level (SPL).
Long term estimations of low frequency noise levels over water from an off-shore wind farm.
Bolin, Karl; Almgren, Martin; Ohlsson, Esbjörn; Karasalo, Ilkka
2014-03-01
This article focuses on computations of low frequency sound propagation from an off-shore wind farm. Two different methods for sound propagation calculations are combined with meteorological data for every 3 hours in the year 2010 to examine the varying noise levels at a reception point at 13 km distance. It is shown that sound propagation conditions play a vital role in the noise impact from the off-shore wind farm and ordinary assessment methods can become inaccurate at longer propagation distances over water. Therefore, this paper suggests that methodologies to calculate noise immission with realistic sound speed profiles need to be combined with meteorological data over extended time periods to evaluate the impact of low frequency noise from modern off-shore wind farms.
NASA Technical Reports Server (NTRS)
Sternfeld, H., Jr.; Hinterkeuser, E. G.; Hackman, R. B.; Davis, J.
1974-01-01
A study was conducted in which test subjects evaluated the sounds of a helicopter, a turbofan STOL and a turbojet airplane while engaged in work and leisure activities. Exposure to a high repetitive density of the aircraft sounds did not make the individual sounds more annoying but did create an unacceptable environment. The application of a time duration term to db(A) resulted in a measure which compared favorably with EPNL as a predictor of annoyance. Temporal variations in background noise level had no significant effect on the rated annoyance.
Assessment and improvement of sound quality in cochlear implant users
Caldwell, Meredith T.; Jiam, Nicole T.
2017-01-01
Objectives Cochlear implants (CIs) have successfully provided speech perception to individuals with sensorineural hearing loss. Recent research has focused on more challenging acoustic stimuli such as music and voice emotion. The purpose of this review is to evaluate and describe sound quality in CI users with the purposes of summarizing novel findings and crucial information about how CI users experience complex sounds. Data Sources Here we review the existing literature on PubMed and Scopus to present what is known about perceptual sound quality in CI users, discuss existing measures of sound quality, explore how sound quality may be effectively studied, and examine potential strategies of improving sound quality in the CI population. Results Sound quality, defined here as the perceived richness of an auditory stimulus, is an attribute of implant‐mediated listening that remains poorly studied. Sound quality is distinct from appraisal, which is generally defined as the subjective likability or pleasantness of a sound. Existing studies suggest that sound quality perception in the CI population is limited by a range of factors, most notably pitch distortion and dynamic range compression. Although there are currently very few objective measures of sound quality, the CI‐MUSHRA has been used as a means of evaluating sound quality. There exist a number of promising strategies to improve sound quality perception in the CI population including apical cochlear stimulation, pitch tuning, and noise reduction processing strategies. Conclusions In the published literature, sound quality perception is severely limited among CI users. Future research should focus on developing systematic, objective, and quantitative sound quality metrics and designing therapies to mitigate poor sound quality perception in CI users. Level of Evidence NA PMID:28894831
NASA Astrophysics Data System (ADS)
Han, Hyung-Suk
2012-12-01
The indoor noise of a ship is usually determined using the A-weighted sound pressure level. However, in order to better understand this phenomenon, evaluation parameters that more accurately reflect the human sense of hearing are required. To find the level of the satisfaction index of the noise inside a naval vessel such as "Loudness" and "Annoyance", psycho-acoustic evaluation of various sound recordings from the naval vessel was performed in a laboratory. The objective of this paper is to develop a single index of "Loudness" and "Annoyance" for noise inside a naval vessel according to a psycho-acoustic evaluation by using psychological responses such as Noise Rating (NR), Noise Criterion (NC), Room Criterion (RC), Preferred Speech Interference Level (PSIL) and loudness level. Additionally, in order to determine a single index of satisfaction for noise such as "Loudness" and "Annoyance", with respect to a human's sense of hearing, a back-propagation neural network is applied.
Lee, Kyoung-Ryul; Jang, Sung Hwan; Jung, Inhwa
2018-08-10
We investigated the acoustic performance of electrostatic sound-generating devices consisting of bi-layer graphene on polyimide film. The total sound pressure level (SPL) of the sound generated from the devices was measured as a function of source frequency by sweeping, and frequency spectra were measured at 1/3 octave band frequencies. The relationship between various operation conditions and total SPL was determined. In addition, the effects of changing voltage level, adding a DC offset, and using two pairs of electrodes were evaluated. It should be noted that two pairs of electrode operations improved sound generation by about 10 dB over all frequency ranges compared with conventional operation. As for the sound-generating capability, total SPL was 70 dBA at 4 kHz when an AC voltage of 100 V pp was applied with a DC offset of 100 V. Acoustic characteristics differed from other types of graphene-based sound generators, such as graphene thermoacoustic devices and graphene polyvinylidene fluoride devices. The effects of diameter and distance between electrodes were also studied, and we found that diameter greatly influenced the frequency response. We anticipate that the design information provided in this paper, in addition to describing key parameters of electrostatic sound-generating devices, will facilitate the commercial development of electrostatic sound-generating systems.
Utilizing lung sounds analysis for the evaluation of acute asthma in small children.
Tinkelman, D G; Lutz, C; Conner, B
1991-09-01
One of the most difficult aspects of management of acute asthma in the small child is the clinician's inability to quantitate the response or lack of response to bronchodilator agents because of the inability of a child this age to perform objective lung measurements in the acute state. The present study was designed to evaluate bronchodilator responsiveness in children between 2 and 6 years of age with wheezing by means of a computerized lung sound analysis, computer digitized airway phonopneumonography. Children between ages 2 and 6 who were experiencing acute exacerbations of asthma were included in this study population. The 43 children were evaluated by physical examination, pulmonary function testing, if possible, by use of (spirometry or peak flow meter) and transmission of lung sounds to a computer using an electronic stethoscope to obtain a phonopneumograph with sound intensity level determinations during tidal breathing. A control group of 20 known asthmatic patients between the ages of 8 and 52 years who also presented to the office with acute asthma were evaluated similarly. In each of these individuals, a physical examination was followed by complete spirometry as well as computer digitized airway phonopneumonography recordings. Following initial measurements, all patients were treated with nebulized albuterol (0.25 mL in 2 mL of saline). Five minutes after completion of the nebulization all patients were reexamined and repeat pulmonary function tests were performed followed by CDAP recordings. In the study group of children, the mean pretreatment sound intensity level was 1,694 (range 557 to 4,950 SD +/- 745).(ABSTRACT TRUNCATED AT 250 WORDS)
Consistent modelling of wind turbine noise propagation from source to receiver.
Barlas, Emre; Zhu, Wei Jun; Shen, Wen Zhong; Dag, Kaya O; Moriarty, Patrick
2017-11-01
The unsteady nature of wind turbine noise is a major reason for annoyance. The variation of far-field sound pressure levels is not only caused by the continuous change in wind turbine noise source levels but also by the unsteady flow field and the ground characteristics between the turbine and receiver. To take these phenomena into account, a consistent numerical technique that models the sound propagation from the source to receiver is developed. Large eddy simulation with an actuator line technique is employed for the flow modelling and the corresponding flow fields are used to simulate sound generation and propagation. The local blade relative velocity, angle of attack, and turbulence characteristics are input to the sound generation model. Time-dependent blade locations and the velocity between the noise source and receiver are considered within a quasi-3D propagation model. Long-range noise propagation of a 5 MW wind turbine is investigated. Sound pressure level time series evaluated at the source time are studied for varying wind speeds, surface roughness, and ground impedances within a 2000 m radius from the turbine.
Consistent modelling of wind turbine noise propagation from source to receiver
Barlas, Emre; Zhu, Wei Jun; Shen, Wen Zhong; ...
2017-11-28
The unsteady nature of wind turbine noise is a major reason for annoyance. The variation of far-field sound pressure levels is not only caused by the continuous change in wind turbine noise source levels but also by the unsteady flow field and the ground characteristics between the turbine and receiver. To take these phenomena into account, a consistent numerical technique that models the sound propagation from the source to receiver is developed. Large eddy simulation with an actuator line technique is employed for the flow modelling and the corresponding flow fields are used to simulate sound generation and propagation. Themore » local blade relative velocity, angle of attack, and turbulence characteristics are input to the sound generation model. Time-dependent blade locations and the velocity between the noise source and receiver are considered within a quasi-3D propagation model. Long-range noise propagation of a 5 MW wind turbine is investigated. Sound pressure level time series evaluated at the source time are studied for varying wind speeds, surface roughness, and ground impedances within a 2000 m radius from the turbine.« less
Consistent modelling of wind turbine noise propagation from source to receiver
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barlas, Emre; Zhu, Wei Jun; Shen, Wen Zhong
The unsteady nature of wind turbine noise is a major reason for annoyance. The variation of far-field sound pressure levels is not only caused by the continuous change in wind turbine noise source levels but also by the unsteady flow field and the ground characteristics between the turbine and receiver. To take these phenomena into account, a consistent numerical technique that models the sound propagation from the source to receiver is developed. Large eddy simulation with an actuator line technique is employed for the flow modelling and the corresponding flow fields are used to simulate sound generation and propagation. Themore » local blade relative velocity, angle of attack, and turbulence characteristics are input to the sound generation model. Time-dependent blade locations and the velocity between the noise source and receiver are considered within a quasi-3D propagation model. Long-range noise propagation of a 5 MW wind turbine is investigated. Sound pressure level time series evaluated at the source time are studied for varying wind speeds, surface roughness, and ground impedances within a 2000 m radius from the turbine.« less
Quiet PROPELLER MRI techniques match the quality of conventional PROPELLER brain imaging techniques.
Corcuera-Solano, I; Doshi, A; Pawha, P S; Gui, D; Gaddipati, A; Tanenbaum, L
2015-06-01
Switching of magnetic field gradients is the primary source of acoustic noise in MR imaging. Sound pressure levels can run as high as 120 dB, capable of producing physical discomfort and at least temporary hearing loss, mandating hearing protection. New technology has made quieter techniques feasible, which range from as low as 80 dB to nearly silent. The purpose of this study was to evaluate the image quality of new commercially available quiet T2 and quiet FLAIR fast spin-echo PROPELLER acquisitions in comparison with equivalent conventional PROPELLER techniques in current day-to-day practice in imaging of the brain. Thirty-four consecutive patients were prospectively scanned with quiet T2 and quiet T2 FLAIR PROPELLER, in addition to spatial resolution-matched conventional T2 and T2 FLAIR PROPELLER imaging sequences on a clinical 1.5T MR imaging scanner. Measurement of sound pressure levels and qualitative evaluation of relative image quality was performed. Quiet T2 and quiet T2 FLAIR were comparable in image quality with conventional acquisitions, with sound levels of approximately 75 dB, a reduction in average sound pressure levels of up to 28.5 dB, with no significant trade-offs aside from longer scan times. Quiet FSE provides equivalent image quality at comfortable sound pressure levels at the cost of slightly longer scan times. The significant reduction in potentially injurious noise is particularly important in vulnerable populations such as children, the elderly, and the debilitated. Quiet techniques should be considered in these special situations for routine use in clinical practice. © 2015 by American Journal of Neuroradiology.
2018-04-01
empirical, external energy-damage correlation methods for evaluating hearing damage risk associated with impulsive noise exposure. AHAAH applies the...is validated against the measured results of human exposures to impulsive sounds, and unlike wholly empirical correlation approaches, AHAAH’s...a measured level (LAEQ8 of 85 dB). The approach in MIL-STD-1474E is very different. Previous standards tried to find a correlation between some
Evaluation of Variable-Depth Liner Configurations for Increased Broadband Noise Reduction
NASA Technical Reports Server (NTRS)
Jones, M. G.; Watson, W. R.; Nark, D. M.; Howerton, B. M.
2015-01-01
This paper explores the effects of variable-depth geometry on the amount of noise reduction that can be achieved with acoustic liners. Results for two variable-depth liners tested in the NASA Langley Grazing Flow Impedance Tube demonstrate significant broadband noise reduction. An impedance prediction model is combined with two propagation codes to predict corresponding sound pressure level profiles over the length of the Grazing Flow Impedance Tube. The comparison of measured and predicted sound pressure level profiles is sufficiently favorable to support use of these tools for investigation of a number of proposed variable-depth liner configurations. Predicted sound pressure level profiles for these proposed configurations reveal a number of interesting features. Liner orientation clearly affects the sound pressure level profile over the length of the liner, but the effect on the total attenuation is less pronounced. The axial extent of attenuation at an individual frequency continues well beyond the location where the liner depth is optimally tuned to the quarter-wavelength of that frequency. The sound pressure level profile is significantly affected by the way in which variable-depth segments are distributed over the length of the liner. Given the broadband noise reduction capability for these liner configurations, further development of impedance prediction models and propagation codes specifically tuned for this application is warranted.
An evaluation of methods for scaling aircraft noise perception
NASA Technical Reports Server (NTRS)
Ollerhead, J. B.
1971-01-01
One hundred and twenty recorded sounds, including jets, turboprops, piston engined aircraft and helicopters were rated by a panel of subjects in a paired comparison test. The results were analyzed to evaluate a number of noise rating procedures in terms of their ability to accurately estimate both relative and absolute perceived noise levels. It was found that the complex procedures developed by Stevens, Zwicker and Kryter are superior to other scales. The main advantage of these methods over the more convenient weighted sound pressure level scales lies in their ability to cope with signals over a wide range of bandwidth. However, Stevens' loudness level scale and the perceived noise level scale both overestimate the growth of perceived level with intensity because of an apparent deficiency in the band level summation rule. A simple correction is proposed which will enable these scales to properly account for the experimental observations.
Discovery of Sound in the Sea (DOSITS) Website Development
2013-03-04
life affect ocean sound levels? • Science of Sound > Sounds in the Sea > How will ocean acidification affect ocean sound levels? • Science of Sound...Science of Sound > Sounds in the Sea > How does shipping affect ocean sound levels? • Science of Sound > Sounds in the Sea > How does marine
Evaluation of community response to wind turbine-related noise in western New York state.
Magari, Shannon R; Smith, Clinton E; Schiff, Martin; Rohr, Annette C
2014-01-01
As the boundaries of harvesting wind energy expand to meet the ever-increasing societal energy demands, the number and size of wind turbines being constructed rises. As part of a larger project to monitor sound in an operating wind park in western New York State, a cross-sectional survey was conducted among individuals living in and around the wind park to characterize the perception, level of annoyance, and self-reported health effects of residents. We conducted the study in a 126 MW wind park consisting of 84 turbines spanning approximately 19 square miles of farmland. Short-term outdoor and indoor sound level measurements were also performed at each dwelling in which a questionnaire was administered. To our knowledge, this study is the first to collect sound measurements at individual residences. There was no apparent exposure-response relationship between an individual's level of annoyance and the short duration sound measurements collected at the time of the survey. There was a correlation between an individual's concern regarding health effects and the prevalence of sleep disturbance and stress among the study population. The siting process is unique to each community with varying degrees of success. Additional sound level measurements inside and outside homes in larger cohorts in concert with detailed questionnaires would be useful in verifying those exposure-response relationships found in studies using calculated sound level data. Additional research should include a detailed investigation of sleep patterns and possible disturbance in those living in and near operating wind turbine projects.
NASA Technical Reports Server (NTRS)
Brown, David; Sutherland, Louis C.
1992-01-01
The preferred descriptor to define the spectral content of sonic booms is the Sound Exposure Spectrum Level, LE(f). This descriptor represents the spectral content of the basic noise descriptors used for describing any single event--the Sound Exposure Level, LE. The latter is equal to ten times the logarithms, to the base ten, of the integral, over the duration of the event, of the square of the instantaneous acoustic pressure, divided by the square of the reference pressure, 20 micro-Pa. When applied to the evaluation of community response to sonic booms, it is customary to use the so-called C-Weighted Sound Exposure Level, LCE, for which the frequency content of the instantaneous acoustic pressure is modified by the C-Weighting curve.
Sound levels in conservative dentistry and endodontics clinic
Dutta, Arindam; Mala, Kundabala; Acharya, Shashi Rashmi
2013-01-01
Aim: To evaluate the sound levels generated in dental clinics of conservative dentistry and endodontics. Material and Methods: A decibel-meter with digital readout was used to measure sound levels at different time intervals at the chairside and at the center of the clinic. Minimum and maximum readings during a 3 min interval were recorded. Results: In the post-graduate (PG) clinic, there was significant difference in noise levels between the chairside (66-81 dB[A]) and the center of the clinic (66-67 dB[A]) at certain times. In the under graduate (UG) clinic, noise levels with suction and either high/slow speed handpieces (67-80 dB[A]) were significantly higher than the center of clinic. Suction alone in the UG clinic (63-75 dB[A]) was significantly quieter than in the PG clinic (69-79 dB[A]). Conclusions: (1) Mean sound levels in the working clinics ranged from 63.0 dB[A] to 81.5 dB[A]. These are within the recommended range for dental equipment. (2) With suction and either low/high speed handpiece combination, the PG clinic was significantly noisier than the UG clinic at several time periods. PMID:23716962
Wang, Ningqian; Wang, Xiao; Yang, Xiaoli; Tang, Jie; Xiao, Zhongju
2014-01-16
In this study, we adopted iso-frequency pure tone bursts to investigate the interdependent effects of sound amplitude/intensity and duration on mice inferior colliculus (IC) neuronal onset responses. On the majority of the sampled neurons (n=57, 89.1%), sound amplitude and duration had effects on the neuronal response to each other by showing complex changes of the rat-intensity function/duration selectivity types and/or best amplitudes (BAs)/durations (BDs), evaluated by spike counts. These results suggested that the balance between the excitatory and inhibitory inputs set by one acoustic parameter, amplitude or duration, affected the neuronal spike counts responses to the other. Neuronal duration selectivity types were altered easily by the low-amplitude sounds while the changes of rate-intensity function types had no obvious preferred stimulus durations. However, the first spike latencies (FSLs) of the onset response neurons were relative stable to iso-amplitude sound durations and changing systematically along with the sound levels. The superimposition of FSL and duration threshold (DT) as a function of stimulus amplitude after normalization indicated that the effects of the sound levels on FSLs are considered on DT actually. © 2013 Published by Elsevier B.V.
Limiting hazardous noise exposure from noisy toys: simple, sticky solutions.
Weinreich, Heather M; Jabbour, Noel; Levine, Samuel; Yueh, Bevan
2013-09-01
To assess noise levels of toys from the Sight & Hearing Association (SHA) 2010 Noisy Toys List and evaluate the change in noise of these toys after covering the speakers with tape or glue. One Group Pretest-Posttest Design. SHA 2010 Toys List (n = 18) toys were tested at distances of 0 and 25 cm from sound source in a soundproof booth using a digital sound-level meter. The dBA level of sound produced by toy was obtained. Toys with speakers (n = 16) were tested before and after altering speakers with plastic packing tape or nontoxic glue. Mean noise level for non-taped toys at 0 and 25 cm was 107.6 dBA (SD ± 8.5) and 82.5 dBA (SD ± 8.8), respectively. With tape, there was a statistically significant decrease in noise level at 0 and 25 cm: 84.2 dBA and 68.2 dBA (P <0.001). With glue, there was a statistically significant decrease in noise level at 0 cm and 25 cm: 79.7 dBA and 66.4 dBA (P <0.001). Both tape and glue significantly decreased the noise level produced by the toys. However, there was no significant difference between tape or glue. Overall, altering the toy can significantly decrease the sound a child may experience when playing with toys. However, some toys, even after altering, still produce sound levels that may be considered dangerous. Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.
Teaching letter sounds to kindergarten English language learners using incremental rehearsal.
Peterson, Meredith; Brandes, Dana; Kunkel, Amy; Wilson, Jennifer; Rahn, Naomi L; Egan, Andrea; McComas, Jennifer
2014-02-01
Proficiency in letter-sound correspondence is important for decoding connected text. This study examined the effects of an evidence-based intervention, incremental rehearsal (IR), on the letter-sound expression of three kindergarten English language learners (ELLs) performing below the district benchmark for letter-sound fluency. Participants were native speakers of Hmong, Spanish, and Polish. A multiple-baseline design across sets of unknown letter sounds was used to evaluate the effects of IR on letter-sound expression. Visual analysis of the data showed an increase in level and trend when IR was introduced in each phase. Percentage of all non-overlapping data (PAND) ranged from 95% to 100%. All participants exceeded expected growth and reached the spring district benchmark for letter-sound fluency. Results suggest that IR is a promising intervention for increasing letter-sound expression for ELLs who evidence delays in acquiring letter sounds. Copyright © 2013 Society for the Study of School Psychology. Published by Elsevier Ltd. All rights reserved.
Acoustic Modeling for Aqua Ventus I off Monhegan Island, ME
DOE Office of Scientific and Technical Information (OSTI.GOV)
Whiting, Jonathan M.; Hanna, Luke A.; DeChello, Nicole L.
2013-10-31
The DeepCwind consortium, led by the University of Maine, was awarded funding under the US Department of Energy’s Offshore Wind Advanced Technology Demonstration Program to develop two floating offshore wind turbines in the Gulf of Maine equipped with Goldwind 6 MW direct drive turbines, as the Aqua Ventus I project. The Goldwind turbines have a hub height of 100 m. The turbines will be deployed in Maine State waters, approximately 2.9 miles off Monhegan Island; Monhegan Island is located roughly 10 miles off the coast of Maine. In order to site and permit the offshore turbines, the acoustic output mustmore » be evaluated to ensure that the sound will not disturb residents on Monhegan Island, nor input sufficient sound levels into the nearby ocean to disturb marine mammals. This initial assessment of the acoustic output focuses on the sound of the turbines in air by modeling the assumed sound source level, applying a sound propagation model, and taking into account the distance from shore.« less
An evaluation of noise and its effects on shuttle crewmembers during STS-50/USML-1
NASA Technical Reports Server (NTRS)
Koros, Anton; Wheelwright, Charles; Adam, Susan
1993-01-01
High noise levels can lead to physiological, psychological, and performance effects in man, ranging from irritability, annoyance, and sleep interference to interference with verbal communication and fatigue, and to temporary or permanent threshold shift at more extreme levels. The current study evaluated the acoustic environment of the STS50/USML-1 mission. The major objectives were to gain subjective assessments of the STS-50 noise levels, document impacts of noise upon crewmember performance, collect inflight sound level measurements, compare noise levels across missions, evaluate the current Shuttle acoustic criterion, and to make recommendations regarding noise specifications for SSF and other long-duration manned space missions. Sound measurements indicated that background noise levels were 60, 64, and 61 A-weighted decibels, respectively, on the Orbiter middeck, flight deck, and Space lab. All levels were rated acceptable, with the Spacelab environment rated the most favorably. Sleep stations afforded attenuation from airborne noise sources, although all crewmembers reported being awakened by crew activity on the middeck. Models of distance for acceptable speech communications were generated, identifying situations of compromised verbal communications to be avoided.
Evaluation of the annoyance due to helicopter rotor noise
NASA Technical Reports Server (NTRS)
Sternfeld, H., Jr.; Doyle, L. B.
1978-01-01
A program was conducted in which 25 test subjects adjusted the levels of various helicopter rotor spectra until the combination of the harmonic noise and a broadband background noise was judged equally annoying as a higher level of the same broadband noise spectrum. The subjective measure of added harmonic noise was equated to the difference in the two levels of broadband noise. The test participants also made subjective evaluations of the rotor noise signatures which they created. The test stimuli consisted of three degrees of rotor impulsiveness, each presented at four blade passage rates. Each of these 12 harmonic sounds was combined with three broadband spectra and was adjusted to match the annoyance of three different sound pressure levels of broadband noise. Analysis of variance indicated that the important variables were level and impulsiveness. Regression analyses indicated that inclusion of crest factor improved correlation between the subjective measures and various objective or physical measures.
Characterizing noise and perceived work environment in a neurological intensive care unit.
Ryherd, Erica E; Waye, Kerstin Persson; Ljungkvist, Linda
2008-02-01
The hospital sound environment is complex. Alarms, medical equipment, activities, and ventilation generate noise that may present occupational problems as well as hinder recovery among patients. In this study, sound measurements and occupant evaluations were conducted in a neurological intensive care unit. Staff completed questionnaires regarding psychological and physiological reactions to the sound environment. A-weighted equivalent, minimum, and maximum (L(Aeq),L(AFMin),L(AFMax)) and C-weighted peak (L(CPeak)) sound pressure levels were measured over five days at patient and staff locations. Acoustical descriptors that may be explored further were investigated, including level distributions, restorative periods, and spectral content. Measurements near the patients showed average L(Aeq) values of 53-58 dB. The mean length of restorative periods (L(Aeq) below 50 dB for more than 5 min) was 9 and 13 min for day and night, respectively. Ninety percent of the time, the L(AFMax) levels exceeded 50 dB and L(CPeak) exceeded 70 dB. Dosimeters worn by the staff revealed higher noise levels. Personnel perceived the noise as contributing to stress symptoms. Compared to the majority of previous studies, this study provides a more thorough description of intensive care noise and aids in understanding how the sound environment may be disruptive to occupants.
Lucke, Roy E; Raub, Richard A; Thunder, Thomas E
2004-01-01
The automated wayside horn system is designed to replace the train horn as a means of alerting motorists to danger and thus enhancing safety at highway-rail grade crossings. Furthermore, the wayside horn directionality is such that the warning sound is broadcast over a smaller sector than the train horn, thereby reducing residential noise. This article examines the results of an evaluation comparing train horns with wayside horns in the village of Mundelein, Illinois, USA. The study derived from previous work in Gering, Nebraska, and Ames, Iowa.During the 3 months covering the 'before' (train horn) period and through to 'after' (wayside horn), more than 19 500 crossing gate closures were recorded on videotape at three crossings. Analysis showed motorist violation of level-crossing laws decreased 68%, from an average rate of 3.53 per 100 gate closings when train horns were in use to 1.12 per 100 with the wayside horn. The decrease was statistically significant. Of equal importance was the decrease in residential noise. Sound measurements taken in a sample of residential yards showed a decrease in sound levels by more than 10 decibels (dB) at most locations. When plotted as sound contours, decreases in the area of coverage ranged from 85% at the 90dB level to 65% at the 70dB level.However, there are two issues with the use of wayside horns that need to be resolved. First, and most important, is that the wayside horn starts sounding when the warning lights begin to flash. This startles motorists, and some stop on the rail tracks. A second issue is the frequent unwarranted activation of the system, which encourages people to ignore the gate.
Mishima, Riho; Kudo, Takumu; Tsunetsugu, Yuko; Miyazaki, Yoshifumi; Yamamura, Chie; Yamada, Yoshiaki
2004-09-01
Effects of sound generated by a dental turbine and a small stream (murmur) and the effects of no sound (null, control) on heart rate, systolic and diastolic blood pressure, and hemodynamic changes (oxygenated, deoxygenated, and total hemoglobin concentrations) in the frontal cortex were measured in 18 young volunteers. Questionnaires completed by the volunteers were also evaluated. Near-infrared spectroscopy and the Finapres technique were employed to measure hemodynamic and vascular responses, respectively. The subjects assessed the murmur, null, and turbine sounds as "pleasant," "natural," and "unpleasant," respectively. Blood pressures changed in response to the murmur, null, and turbine sound stimuli as expected: lower than the control level, unchanged, and higher than the control level, respectively. Mean blood pressure values tended to increase gradually over the recording time even during the null sound stimulation, possibly because of the recording environment. Oxygenated hemoglobin concentrations decreased drastically in response to the dental turbine sound, while deoxygenated hemoglobin concentrations remained unchanged and thus total hemoglobin concentrations decreased (due to the decreased oxygenated hemoglobin concentrations). Hemodynamic responses to the murmuring sound and the null sound were slight or unchanged, respectively. Surprisingly, heart rate measurements remained fairly stable in response to the stimulatory noises. In conclusion, we demonstrate here that sound generated by a dental turbine may affect cerebral blood flow and metabolism as well as autonomic responses. Copyright 2004 The Society of the Nippon Dental University
Garinis, Angela C.; Liao, Selena; Cross, Campbell P.; Galati, Johnathan; Middaugh, Jessica L.; Mace, Jess C.; Wood, Anna-Marie; McEvoy, Lindsey; Moneta, Lauren; Lubianski, Troy; Coopersmith, Noe; Vigo, Nicholas; Hart, Christopher; Riddle, Artur; Ettinger, Olivia; Nold, Casey; Durham, Heather; MacArthur, Carol; McEvoy, Cynthia; Steyger, Peter S.
2017-01-01
Objective Hearing loss rates in infants admitted to neonatal intensive care units (NICU) run at 2–15%, compared to 0.3% in full-term births. The etiology of this difference remains poorly understood. We examined whether the level of ambient sound and/or cumulative gentamicin (an aminoglycoside) exposure affect NICU hearing screening results, as either exposure can cause acquired, permanent hearing loss. We hypothesized that higher levels of ambient sound in the NICU, and/or gentamicin dosing, increase the risk of referral on the distortion product otoacoustic emission (DPOAE) assessments and/or automated auditory brainstem response (AABR) screens. Methods This was a prospective pilot outcomes study of 82 infants (<37 weeks gestational age) admitted to the NICU at Oregon Health & Science University. An ER-200D sound pressure level dosimeter was used to collect daily sound exposure in the NICU for each neonate. Gentamicin dosing was also calculated for each infant, including the total daily dose based on body mass (mg/kg/day), as well as the total number of treatment days. DPOAE and AABR assessments were conducted prior to discharge to evaluate hearing status. Exclusion criteria included congenital infections associated with hearing loss, and congenital craniofacial or otologic abnormalities. Results The mean level of ambient sound was 62.9 dBA (range 51.8–70.6 dBA), greatly exceeding American Academy of Pediatrics (AAP) recommendation of <45.0 dBA. More than 80% of subjects received gentamicin treatment. The referral rate for (i) AABRs, (frequency range: ~1000–4000 Hz), was 5%; (ii) DPOAEs with a broad F2 frequency range (2063–10031 Hz) was 39%; (iii) DPOAEs with a low-frequency F2 range (<4172 Hz) was 29%, and (iv) DPOAEs with a high-frequency F2 range (>4172 Hz) was 44%. DPOAE referrals were significantly greater for infants receiving >2 days of gentamicin dosing compared to fewer doses (p= 0.004). The effect of sound exposure and gentamicin treatment on hearing could not be determined due to the low number of NICU infants without gentamicin exposure (for control comparisons). Conclusion All infants were exposed to higher levels of ambient sound that substantially exceed AAP guidelines. More referrals were generated by DPOAE assessments than with AABR screens, with significantly more DPOAE referrals with a high-frequency F2 range, consistent with sound- and/or gentamicin-induced cochlear dysfunction. Adding higher frequency DPOAE assessments to existing NICU hearing screening protocols could better identify at-risk infants to be referred for diagnostic evaluation. PMID:28483249
Analysis of impact/impulse noise for predicting noise induced hearing loss
NASA Astrophysics Data System (ADS)
Vipperman, Jeffrey S.; Prince, Mary M.; Flamm, Angela M.
2003-04-01
Studies indicate that the statistical properties and temporal structure of the sound signal are important in determining the extent of hearing hazard. As part of a pilot study to examine hearing conservation program effectiveness, NIOSH collected noise samples of impact noise sources in an automobile stamping plant, focusing on jobs with peak sound levels (Lpk) of greater than 120 dB. Digital tape recordings of sounds were collected using a Type I Precision Sound Level Meter and microphone connected to a DAT tape recorder. The events were archived and processed as .wav files to extract single events of interest on CD-R media and CD audio media. A preliminary analysis of sample wavelet files was conducted to characterize each event using metrics such as the number of impulses per unit time, the repetition rate or temporal pattern of these impulses, index of peakedness, crest factor, kurtosis, coefficient of kurtosis, rise time, fall time, and peak time. The spectrum, duration, and inverse of duration for each waveform were also computed. Finally, the data were evaluated with the Auditory Hazard Assessment Algorithm (AHAAH). Improvements to data collection for a future study examining different strategies for evaluating industrial noise exposure will be discussed.
Assessment and analysis of noise pollution in Biskra public gardens (Algeria)
NASA Astrophysics Data System (ADS)
Bouzir, Tallal Abdel Karim; Zemmouri, Noureddine; Berkouk, Djihed
2018-05-01
A quantitative evaluation of noise pollution in the public gardens of Biskra, Algeria, was carried out in this research. The equivalent sound level (leq1min) was measured in 27 points distributed over the seven main gardens of the city. The results of the measurements show that the measured level of sound intensity varies from 56.38 dB in the Landon garden to 62.55 dB in the Larbi Ben Mhidi garden. By comparing, the measured values with the noise limit values recommended by the national legislation, the standards of the World Health Organization and the United States Environmental Protection Agency; it is clear that the sound environment in these public gardens do not comply with the recognized standards of acoustic comfort. The gardens' spaces are heavily over-exposed to traffic noise resulting in high levels acoustic pollution.
DuBois, Matthew R; Volpe, Robert J; Burns, Matthew K; Hoffman, Jessica A
2016-12-01
Knowledge of letters sounds has been identified as a primary objective of preschool instruction and intervention. Despite this designation, large disparities exist in the number of letter sounds children know at school entry. Enhancing caregivers' ability to teach their preschool-aged children letter sounds may represent an effective practice for reducing this variability and ensuring that more children are prepared to experience early school success. This study used a non-concurrent multiple-baseline-across-participants design to evaluate the effectiveness of caregivers (N=3) delivering a computer-assisted tutoring program (Tutoring Buddy) targeting letter sound knowledge to their preschool-aged children. Visual analyses and effect size estimates derived from Percentage of All Non-Overlapping Data (PAND) statistics indicated consistent results for letter sound acquisition, as 6weeks of intervention yielded large effects for letter sound knowledge (LSK) across all three children. Large effect sizes were also found for letter sound fluency (LSF) and nonsense word fluency (NWF) for two children. All three caregivers rated the intervention as highly usable and were able to administer it with high levels of fidelity. Taken together, the results of the present study found Tutoring Buddy to be an effective, simple, and usable way for the caregivers to support their children's literacy development. Copyright © 2016 Society for the Study of School Psychology. Published by Elsevier Ltd. All rights reserved.
Evaluating the performance of active noise control systems in commercial and industrial applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Depies, C.; Deneen, S.; Lowe, M.
1995-06-01
Active sound cancellation technology is increasingly being used to quiet commercial and industrial air-moving devices. Engineers and designers are implementing active or combination active/passive technology to control sound quality in the workplace and the acoustical environment in residential areas near industrial facilities. Sound level measurements made before and after the installation of active systems have proved that significant improvements in sound quality can be obtained even if there is little or no change in the NC/RC or dBA numbers. Noise produced by centrifugal and vane-axial fans, pumps and blowers, commonly used for ventilation and material movement in industry, are frequentlymore » dominated by high amplitude, tonal noise at low frequencies. And the low-frequency noise produced by commercial air handlers often has less tonal and more broadband characteristics, resulting in audible duct rumble noise and objectionable room spectrums. Because the A-weighting network, which is commonly used for industrial noise measurements, de-emphasizes low frequencies, its single number rating can be misleading in terms of judging the overall subjective sound quality in impacted areas and assessing the effectiveness of noise control measures. Similarly, NC values, traditionally used for commercial HVAC acoustical design criteria, can be governed by noise at any frequency and cannot accurately depict human judgment of the aural comfort level. Analyses of frequency spectrum characteristics provide the most effective means of assessing sound quality and determining mitigative measures for achieving suitable background sound levels.« less
Bottom-up approach for microstructure optimization of sound absorbing materials.
Perrot, Camille; Chevillotte, Fabien; Panneton, Raymond
2008-08-01
Results from a numerical study examining micro-/macrorelations linking local geometry parameters to sound absorption properties are presented. For a hexagonal structure of solid fibers, the porosity phi, the thermal characteristic length Lambda('), the static viscous permeability k(0), the tortuosity alpha(infinity), the viscous characteristic length Lambda, and the sound absorption coefficient are computed. Numerical solutions of the steady Stokes and electrical equations are employed to provide k(0), alpha(infinity), and Lambda. Hybrid estimates based on direct numerical evaluation of phi, Lambda('), k(0), alpha(infinity), Lambda, and the analytical model derived by Johnson, Allard, and Champoux are used to relate varying (i) throat size, (ii) pore size, and (iii) fibers' cross-section shapes to the sound absorption spectrum. The result of this paper tends to demonstrate the important effect of throat size in the sound absorption level, cell size in the sound absorption frequency selectivity, and fibers' cross-section shape in the porous material weight reduction. In a hexagonal porous structure with solid fibers, the sound absorption level will tend to be maximized with a 48+/-10 microm throat size corresponding to an intermediate resistivity, a 13+/-8 microm fiber radius associated with relatively small interfiber distances, and convex triangular cross-section shape fibers allowing weight reduction.
Exploring positive hospital ward soundscape interventions.
Mackrill, J; Jennings, P; Cain, R
2014-11-01
Sound is often considered as a negative aspect of an environment that needs mitigating, particularly in hospitals. It is worthwhile however, to consider how subjective responses to hospital sounds can be made more positive. The authors identified natural sound, steady state sound and written sound source information as having the potential to do this. Listening evaluations were conducted with 24 participants who rated their emotional (Relaxation) and cognitive (Interest and Understanding) response to a variety of hospital ward soundscape clips across these three interventions. A repeated measures ANOVA revealed that the 'Relaxation' response was significantly affected (n(2) = 0.05, p = 0.001) by the interventions with natural sound producing a 10.1% more positive response. Most interestingly, written sound source information produced a 4.7% positive change in response. The authors conclude that exploring different ways to improve the sounds of a hospital offers subjective benefits that move beyond sound level reduction. This is an area for future work to focus upon in an effort to achieve more positively experienced hospital soundscapes and environments. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Zhang, Bin; Song, Wen-Ai; Wei, Yue-Juan; Zhang, Dong-Song; Liu, Wen-Yi
2017-06-15
By simulating the sound field of a round piston transducer with the Kirchhoff integral theorem and analyzing the shape of ultrasound beams and propagation characteristics in a metal container wall, this study presents a model for calculating the echo sound pressure by using the Kirchhoff paraxial approximation theory, based on which and according to different ultrasonic impedance between gas and liquid media, a method for detecting the liquid level from outside of sealed containers is proposed. Then, the proposed method is evaluated through two groups of experiments. In the first group, three kinds of liquid media with different ultrasonic impedance are used as detected objects; the echo sound pressure is calculated by using the proposed model under conditions of four sets of different wall thicknesses. The changing characteristics of the echo sound pressure in the entire detection process are analyzed, and the effects of different ultrasonic impedance of liquids on the echo sound pressure are compared. In the second group, taking water as an example, two transducers with different radii are selected to measure the liquid level under four sets of wall thickness. Combining with sound field characteristics, the influence of different size transducers on the pressure calculation and detection resolution are discussed and analyzed. Finally, the experimental results indicate that measurement uncertainly is better than ±5 mm, which meets the industrial inspection requirements.
Zhang, Bin; Song, Wen-Ai; Wei, Yue-Juan; Zhang, Dong-Song; Liu, Wen-Yi
2017-01-01
By simulating the sound field of a round piston transducer with the Kirchhoff integral theorem and analyzing the shape of ultrasound beams and propagation characteristics in a metal container wall, this study presents a model for calculating the echo sound pressure by using the Kirchhoff paraxial approximation theory, based on which and according to different ultrasonic impedance between gas and liquid media, a method for detecting the liquid level from outside of sealed containers is proposed. Then, the proposed method is evaluated through two groups of experiments. In the first group, three kinds of liquid media with different ultrasonic impedance are used as detected objects; the echo sound pressure is calculated by using the proposed model under conditions of four sets of different wall thicknesses. The changing characteristics of the echo sound pressure in the entire detection process are analyzed, and the effects of different ultrasonic impedance of liquids on the echo sound pressure are compared. In the second group, taking water as an example, two transducers with different radii are selected to measure the liquid level under four sets of wall thickness. Combining with sound field characteristics, the influence of different size transducers on the pressure calculation and detection resolution are discussed and analyzed. Finally, the experimental results indicate that measurement uncertainly is better than ±5 mm, which meets the industrial inspection requirements. PMID:28617326
Mercadíe, Lolita; Mick, Gérard; Guétin, Stéphane; Bigand, Emmanuel
2015-10-01
In fibromyalgia, pain symptoms such as hyperalgesia and allodynia are associated with fatigue. Mechanisms underlying such symptoms can be modulated by listening to pleasant music. We expected that listening to music, because of its emotional impact, would have a greater modulating effect on the perception of pain and fatigue in patients with fibromyalgia than listening to nonmusical sounds. To investigate this hypothesis, we carried out a 4-week study in which patients with fibromyalgia listened to either preselected musical pieces or environmental sounds when they experienced pain in active (while carrying out a physical activity) or passive (at rest) situations. Concomitant changes of pain and fatigue levels were evaluated. When patients listened to music or environmental sounds at rest, pain and fatigue levels were significantly reduced after 20 minutes of listening, with no difference of effect magnitude between the two stimuli. This improvement persisted 10 minutes after the end of the listening session. In active situations, pain did not increase in presence of the two stimuli. Contrary to our expectations, music and environmental sounds produced a similar relieving effect on pain and fatigue, with no benefit gained by listening to pleasant music over environmental sounds. Copyright © 2015 American Society for Pain Management Nursing. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Matetic, Rudy J.
Over-exposure to noise remains a widespread and serious health hazard in the U.S. mining industries despite 25 years of regulation. Every day, 80% of the nation's miners go to work in an environment where the time weighted average (TWA) noise level exceeds 85 dBA and more than 25% of the miners are exposed to a TWA noise level that exceeds 90 dBA, the permissible exposure limit (PEL). Additionally, MSHA coal noise sample data collected from 2000 to 2002 show that 65% of the equipment whose operators exceeded 100% noise dosage comprise only seven different types of machines; auger miners, bulldozers, continuous miners, front end loaders, roof bolters, shuttle cars (electric), and trucks. In addition, the MSHA data indicate that the roof bolter is third among all the equipment and second among equipment in underground coal whose operators exceed 100% dosage. A research program was implemented to: (1) determine, characterize and to measure sound power levels radiated by a roof bolting machine during differing drilling configurations (thrust, rotational speed, penetration rate, etc.) and utilizing differing types of drilling methods in high compressive strength rock media (>20,000 psi). The research approach characterized the sound power level results from laboratory testing and provided the mining industry with empirical data relative to utilizing differing noise control technologies (drilling configurations and types of drilling methods) in reducing sound power level emissions on a roof bolting machine; (2) distinguish and correlate the empirical data into one, statistically valid, equation, in which, provided the mining industry with a tool to predict overall sound power levels of a roof bolting machine given any type of drilling configuration and drilling method utilized in industry; (3) provided the mining industry with several approaches to predict or determine sound pressure levels in an underground coal mine utilizing laboratory test results from a roof bolting machine and (4) described a method for determining an operators' noise dosage of a roof bolting machine utilizing predicted or determined sound pressure levels.
Development of rotorcraft interior noise control concepts. Phase 2: Full scale testing, revision 1
NASA Technical Reports Server (NTRS)
Yoerkie, C. A.; Gintoli, P. J.; Moore, J. A.
1986-01-01
The phase 2 effort consisted of a series of ground and flight test measurements to obtain data for validation of the Statistical Energy Analysis (SEA) model. Included in the gound tests were various transfer function measurements between vibratory and acoustic subsystems, vibration and acoustic decay rate measurements, and coherent source measurements. The bulk of these, the vibration transfer functions, were used for SEA model validation, while the others provided information for characterization of damping and reverberation time of the subsystems. The flight test program included measurements of cabin and cockpit sound pressure level, frame and panel vibration level, and vibration levels at the main transmission attachment locations. Comparisons between measured and predicted subsystem excitation levels from both ground and flight testing were evaluated. The ground test data show good correlation with predictions of vibration levels throughout the cabin overhead for all excitations. The flight test results also indicate excellent correlation of inflight sound pressure measurements to sound pressure levels predicted by the SEA model, where the average aircraft speech interference level is predicted within 0.2 dB.
Habibi, Ehsanollah; Dehghan, Habibollah; Dehkordy, Sina Eshraghy; Maracy, Mohammad Reza
2013-01-01
Background: Among the most important and effective factors affecting the efficiency of the human workforce are accuracy, promptness, and ability. In the context of promoting levels and quality of productivity, the aim of this study was to investigate the effects of exposure to noise on the rate of errors, speed of work, and capability in performing manual activities. Methods: This experimental study was conducted on 96 students (52 female and 44 male) of the Isfahan Medical Science University with the average and standard deviations of age, height, and weight of 22.81 (3.04) years, 171.67 (8.51) cm, and 65.05 (13.13) kg, respectively. Sampling was conducted with a randomized block design. Along with controlling for intervening factors, a combination of sound pressure levels [65 dB (A), 85 dB (A), and 95 dB (A)] and exposure times (0, 20, and 40) were used for evaluation of precision and speed of action of the participants, in the ergonomic test of two-hand coordination. Data was analyzed by SPSS18 software using a descriptive and analytical statistical method by analysis of covariance (ANCOVA) repeated measures. Results: The results of this study showed that increasing sound pressure level from 65 to 95 dB in network ‘A’ increased the speed of work (P < 0.05). Increase in the exposure time (0 to 40 min of exposure) and gender showed no significant differences statistically in speed of work (P > 0.05). Male participants got annoyed from the noise more than females. Also, increase in sound pressure level increased the rate of error (P < 0.05). Conclusions: According to the results of this research, increasing the sound pressure level decreased efficiency and increased the errors and in exposure to sounds less than 85 dB in the beginning, the efficiency decreased initially and then increased in a mild slope. PMID:23930164
Estimating occupant satisfaction of HVAC system noise using quality assessment index.
Forouharmajd, Farhad; Nassiri, Parvin; Monazzam, Mohammad R; Yazdchi, Mohammadreza
2012-01-01
Noise may be defined as any unwanted sound. Sound becomes noise when it is too loud, unexpected, uncontrolled, happens at the wrong time, contains unwanted pure tones or unpleasant. In addition to being annoying, loud noise can cause hearing loss, and, depending on other factors, can affect stress level, sleep patterns and heart rate. The primary object for determining subjective estimations of loudness is to present sounds to a sample of listeners under controlled conditions. In heating, ventilation and air conditioning (HVAC) systems only the ventilation fan industry (e.g., bathroom exhaust and sidewall propeller fans) uses loudness ratings. In order to find satisfaction, percent of exposure to noise is the valuable issue for the personnel who are working in these areas. The room criterion (RC) method has been defined by ANSI standard S12.2, which is based on measured levels of in HVAC systems noise in spaces and is used primarily as a diagnostic tool. The RC method consists of a family of criteria curves and a rating procedure. RC measures background noise in the building over the frequency range of 16-4000 Hz. This rating system requires determination of the mid-frequency average level and determining the perceived balance between high-frequency (HF) sound and low-frequency (LF) sound. The arithmetic average of the sound levels in the 500, 1000 and 2000 Hz octave bands is 44.6 dB; therefore, the RC 45 curve is selected as the reference for spectrum quality evaluation. The spectral deviation factors in the LF, medium-frequency sound and HF regions are 2.9, 7.5 and -2.3, respectively, giving a Quality Assessment Index (QAI) of 9.8. This concludes the QAI is useful in estimating an occupant's probable reaction when the system design does not produce optimum sound quality. Thus, a QAI between 5 and 10 dB represents a marginal situation in which acceptance by an occupant is questionable. However, when sound pressure levels in the 16 or 31.5 Hz octave bands exceed 65 dB, vibration in lightweight office construction is possible.
A geospatial model of ambient sound pressure levels in the contiguous United States.
Mennitt, Daniel; Sherrill, Kirk; Fristrup, Kurt
2014-05-01
This paper presents a model that predicts measured sound pressure levels using geospatial features such as topography, climate, hydrology, and anthropogenic activity. The model utilizes random forest, a tree-based machine learning algorithm, which does not incorporate a priori knowledge of source characteristics or propagation mechanics. The response data encompasses 270 000 h of acoustical measurements from 190 sites located in National Parks across the contiguous United States. The explanatory variables were derived from national geospatial data layers and cross validation procedures were used to evaluate model performance and identify variables with predictive power. Using the model, the effects of individual explanatory variables on sound pressure level were isolated and quantified to reveal systematic trends across environmental gradients. Model performance varies by the acoustical metric of interest; the seasonal L50 can be predicted with a median absolute deviation of approximately 3 dB. The primary application for this model is to generalize point measurements to maps expressing spatial variation in ambient sound levels. An example of this mapping capability is presented for Zion National Park and Cedar Breaks National Monument in southwestern Utah.
Underwater temporary threshold shift in pinnipeds: effects of noise level and duration.
Kastak, David; Southall, Brandon L; Schusterman, Ronald J; Kastak, Colleen Reichmuth
2005-11-01
Behavioral psychophysical techniques were used to evaluate the residual effects of underwater noise on the hearing sensitivity of three pinnipeds: a California sea lion (Zalophus californianus), a harbor seal (Phoca vitulina), and a northern elephant seal (Mirounga angustirostris). Temporary threshold shift (TTS), defined as the difference between auditory thresholds obtained before and after noise exposure, was assessed. The subjects were exposed to octave-band noise centered at 2500 Hz at two sound pressure levels: 80 and 95 dB SL (re: auditory threshold at 2500 Hz). Noise exposure durations were 22, 25, and 50 min. Threshold shifts were assessed at 2500 and 3530 Hz. Mean threshold shifts ranged from 2.9-12.2 dB. Full recovery of auditory sensitivity occurred within 24 h of noise exposure. Control sequences, comprising sham noise exposures, did not result in significant mean threshold shifts for any subject. Threshold shift magnitudes increased with increasing noise sound exposure level (SEL) for two of the three subjects. The results underscore the importance of including sound exposure metrics (incorporating sound pressure level and exposure duration) in order to fully assess the effects of noise on marine mammal hearing.
Ambient Noise in Emergency Rooms and Its Health Hazards
Filus, Walderes; Lacerda, Adriana Bender Moreira de; Albizu, Evelyn
2014-01-01
Introduction The occupational risk due to high levels of noise in the hospital environment has been recognized, and the National Agency of Sanitary Surveillance of the Ministry of Health recommends evaluation and control of noise in hospital areas. Objectives To assess the sound environment in the emergency ward of a general trauma reference hospital in the city of Curitiba, Parana State, Brazil. Methods In this descriptive study, noise levels were assessed on mornings, afternoons, and evenings using an integrating Bruel & Kjaer (Denmark) calibrated sound level meter, type 2230. Ten indoor points in the emergency ward were assessed; the helicopter as well as several available pieces of equipment in the ward were assessed individually. Results Noise levels in sound pressure level ambiance [dBA] ranged from 56.6 to 68.8. The afternoon period was the noisiest. The helicopter at 119 dBA and the cast saw at 90 dBA were the noisiest equipment, and the lowest noise level found was the activated oximeter at 61.0 dBA. Conclusion In all assessed points, noise levels were above the comfort levels recommended by the Brazilian Association of Technical Standards (1987), which may harm users' and professionals' health as well as influence professional performance in the emergency ward. Sound pressure levels of the helicopter and cast saw reach high hearing hazard levels, requiring professionals to use individual protection equipment, and point to the need for creation and implementation of effective control measures of noise levels in emergency wards. PMID:26157493
Neonatal incubators: a toxic sound environment for the preterm infant?*.
Marik, Paul E; Fuller, Christopher; Levitov, Alexander; Moll, Elizabeth
2012-11-01
High sound pressure levels may be harmful to the maturing newborn. Current guidelines suggest that the sound pressure levels within a neonatal intensive care unit should not exceed 45 dB(A). It is likely that environmental noise as well as the noise generated by the incubator fan and respiratory equipment may contribute to the total sound pressure levels. Knowledge of the contribution of each component and source is important to develop effective strategies to reduce noise within the incubator. The objectives of this study were to determine the sound levels, sound spectra, and major sources of sound within a modern neonatal incubator (Giraffe Omnibed; GE Healthcare, Helsinki, Finland) using a sound simulation study to replicate the conditions of a preterm infant undergoing high-frequency jet ventilation (Life Pulse, Bunnell, UT). Using advanced sound data acquisition and signal processing equipment, we measured and analyzed the sound level at a dummy infant's ear and at the head level outside the enclosure. The sound data time histories were digitally acquired and processed using a digital Fast Fourier Transform algorithm to provide spectra of the sound and cumulative sound pressure levels (dBA). The simulation was done with the incubator cooling fan and ventilator switched on or off. In addition, tests were carried out with the enclosure sides closed and hood down and then with the enclosure sides open and the hood up to determine the importance of interior incubator reverberance on the interior sound levels With all the equipment off and the hood down, the sound pressure levels were 53 dB(A) inside the incubator. The sound pressure levels increased to 68 dB(A) with all equipment switched on (approximately 10 times louder than recommended). The sound intensity was 6.0 × 10(-8) watts/m(2); this sound level is roughly comparable with that generated by a kitchen exhaust fan on high. Turning the ventilator off reduced the overall sound pressure levels to 64 dB(A) and the sound pressure levels in the low-frequency band of 0 to 100 Hz were reduced by 10 dB(A). The incubator fan generated tones at 200, 400, and 600 Hz that raised the sound level by approximately 2 dB(A)-3 dB(A). Opening the enclosure (with all equipment turned on) reduced the sound levels above 50 Hz by reducing the revereberance within the enclosure. The sound levels, especially at low frequencies, within a modern incubator may reach levels that are likely to be harmful to the developing newborn. Much of the noise is at low frequencies and thus difficult to reduce by conventional means. Therefore, advanced forms of noise control are needed to address this issue.
Factors affecting measured aircraft sound levels in the vicinity of start-of-takeoff roll
NASA Astrophysics Data System (ADS)
Richard, Horonjeff; Fleming, Gregg G.; Rickley, Edward J.; Connor, Thomas L.
This paper presents the findings of a recently conducted measurement and analysis program of jet transport aircraft sound levels in the vicinity of the star-of-takeoff roll. The purpose of the program was two-fold: (1) to evaluate the computational accuracy of the Federal Aviation Administration's Integrated Noise Model (INM) in the vicinity of start-of-takeoff roll with a recently updated database (INM 3.10), and (2) to provide guidance for future model improvements. Focusing on the second of these two goals, this paper examines several factors affecting Sound Exposure Levels (SELs) in the hemicircular area behind the aircraft brake release point at the start-of-takeoff. In addition to the aircraft type itself, these factors included the geometric relationship of the measurement site to the runway, the wind velocity (speed and direction), aircraft grow weight, and start-of-roll mode (static or rolling start).
Disher, Timothy C; Benoit, Britney; Inglis, Darlene; Burgess, Stacy A; Ellsmere, Barbara; Hewitt, Brenda E; Bishop, Tanya M; Sheppard, Christopher L; Jangaard, Krista A; Morrison, Gavin C; Campbell-Yeo, Marsha L
To identify baseline sound levels, patterns of sound levels, and potential barriers and facilitators to sound level reduction. The study setting was neonatal and pediatric intensive care units in a tertiary care hospital. Participants were staff in both units and parents of currently hospitalized children or infants. One 24-hour sound measurements and one 4-hour sound measurement linked to observed sound events were conducted in each area of the center's neonatal intensive care unit. Two of each measurement type were conducted in the pediatric intensive care unit. Focus groups were conducted with parents and staff. Transcripts were analyzed with descriptive content analysis and themes were compared against results from quantitative measurements. Sound levels exceeded recommended standards at nearly every time point. The most common code was related to talking. Themes from focus groups included the critical care context and sound levels, effects of sound levels, and reducing sound levels-the way forward. Results are consistent with work conducted in other critical care environments. Staff and families realize that high sound levels can be a problem, but feel that the culture and context are not supportive of a quiet care space. High levels of ambient sound suggest that the largest changes in sound levels are likely to come from design and equipment purchase decisions. L10 and Lmax appear to be the best outcomes for measurement of behavioral interventions.
Park, H K; Bradley, J S
2009-09-01
Subjective ratings of the audibility, annoyance, and loudness of music and speech sounds transmitted through 20 different simulated walls were used to identify better single number ratings of airborne sound insulation. The first part of this research considered standard measures such as the sound transmission class the weighted sound reduction index (R(w)) and variations of these measures [H. K. Park and J. S. Bradley, J. Acoust. Soc. Am. 126, 208-219 (2009)]. This paper considers a number of other measures including signal-to-noise ratios related to the intelligibility of speech and measures related to the loudness of sounds. An exploration of the importance of the included frequencies showed that the optimum ranges of included frequencies were different for speech and music sounds. Measures related to speech intelligibility were useful indicators of responses to speech sounds but were not as successful for music sounds. A-weighted level differences, signal-to-noise ratios and an A-weighted sound transmission loss measure were good predictors of responses when the included frequencies were optimized for each type of sound. The addition of new spectrum adaptation terms to R(w) values were found to be the most practical approach for achieving more accurate predictions of subjective ratings of transmitted speech and music sounds.
Stability of sonic boom metrics regarding signature distortions from atmospheric turbulence.
Doebler, William J; Sparrow, Victor W
2017-06-01
The degree of insensitivity to atmospheric turbulence was evaluated for five metrics (A-, B-, E-weighted sound exposure level, Stevens Mark VII Perceived Level, and NASA's Indoor Sonic Boom Annoyance Predictor) that correlate to human annoyance from sonic booms. Eight N-wave shaped sonic booms from NASA's FaINT experiment and five simulated "low-boom" sonic booms were turbulized by Locey's ten atmospheric filter functions. The B-weighted sound exposure level value changed the least due to the turbulence filters for twelve of thirteen booms. This makes it the most turbulence stable metric which may be useful for quiet supersonic aircraft certification.
MP3 player listening habits of 17 to 23 year old university students.
McNeill, Kylie; Keith, Stephen E; Feder, Katya; Konkle, Anne T M; Michaud, David S
2010-08-01
This study evaluated the potential risk to hearing associated with the use of portable digital audio players. Twenty-eight university students (12 males, 16 females; aged 17-23) completed a 49-item questionnaire assessing user listening habits and subjective measures of hearing health. Sound level measurements of participants' self-identified typical and 'worst case' volume levels were taken in different classrooms with background sound levels between 43 and 52 dBA. The median frequency and duration of use was 2 h per day, 6.5 days a week. The median sound levels and interquartile ranges (IQR) at typical and 'worst case' volume settings were 71 dBA (IQR=12) and 79 dBA (IQR=9), respectively. When typical sound levels were considered with self-reported duration of daily use, none of the participants surpassed Leq(8) 85 dBA. On the questionnaire, 19 students reported experiencing at least one symptom of possible noise-induced hearing loss. Significant differences in MP3 user listening patterns were found between respondents who had experienced tinnitus and those who had not. The findings add to a growing body of literature that collectively supports a need for further research investigating MP3 player user listening habits in order to assess their potential risk to hearing health.
Environment in pediatric wards: light, sound, and temperature.
Oliveira, Lia; Gomes, Cláudia; Bacelar Nicolau, Leonor; Ferreira, Luís; Ferreira, Rosário
2015-09-01
The mutual relationship between sleep and disease is well known, becoming more relevant whenever the disease leads to hospitalization. We intend to describe patterns of environmental factors of some pediatric wards, and to verify if these are in line with those recommended. As a secondary aim, we characterize sleep quality during hospitalization. Five pediatric wards of a tertiary-level hospital were included. Light, sound, and temperature were measured and assessed through descriptive statistics. The following recommended values were considered: maximum light 100 Lux, maximum sound 45 dB, and optimal temperature 20-24 °C. A questionnaire was prepared to assess children's sleep, and it was completed by a caregiver. Light values were within the desirable limits for 86% of evaluated time. In all wards, the intensity of sound was much higher than desirable, being above 45 dB during 85% of evaluated time. The temperature was above 24 °C during 78% of total time. Based on 34 answered questionnaires (out of 50 distributed), almost half of the respondents believe that sleep quality and restlessness are worse at the hospital. Most children slept for a longer time at home. Eighteen children awoke more times at the hospital, and those awakenings were mostly attributed to noise. The sound and temperature were higher than recommended. The different values between these wards may be due to different levels of care, but this shows that there are no standard rules on this matter. A worse quality and shorter duration of sleep at hospital were reported. Comprehensive studies are necessary to evaluate the impact of environmental factors on disease recovery. Copyright © 2015 Elsevier B.V. All rights reserved.
Numerical simulation of the processes in the normal incidence tube for high acoustic pressure levels
NASA Astrophysics Data System (ADS)
Fedotov, E. S.; Khramtsov, I. V.; Kustov, O. Yu.
2016-10-01
Numerical simulation of the acoustic processes in an impedance tube at high levels of acoustic pressure is a way to solve a problem of noise suppressing by liners. These studies used liner specimen that is one cylindrical Helmholtz resonator. The evaluation of the real and imaginary parts of the liner acoustic impedance and sound absorption coefficient was performed for sound pressure levels of 130, 140 and 150 dB. The numerical simulation used experimental data having been obtained on the impedance tube with normal incidence waves. At the first stage of the numerical simulation it was used the linearized Navier-Stokes equations, which describe well the imaginary part of the liner impedance whatever the sound pressure level. These equations were solved by finite element method in COMSOL Multiphysics program in axisymmetric formulation. At the second stage, the complete Navier-Stokes equations were solved by direct numerical simulation in ANSYS CFX in axisymmetric formulation. As the result, the acceptable agreement between numerical simulation and experiment was obtained.
Stability of sonic boom metrics regarding signature distortions from atmospheric turbulence
DOT National Transportation Integrated Search
2017-06-19
The degree of insensitivity to atmospheric turbulence was evaluated for five metrics (A-, B-, E-weighted sound exposure level, Stevens Mark VII Perceived Level, and NASA's Indoor Sonic Boom Annoyance Predictor) that correlate to human annoyance from ...
Keshavarz, Behrang; Campos, Jennifer L; DeLucia, Patricia R; Oberfeld, Daniel
2017-04-01
Estimating time to contact (TTC) involves multiple sensory systems, including vision and audition. Previous findings suggested that the ratio of an object's instantaneous optical size/sound intensity to its instantaneous rate of change in optical size/sound intensity (τ) drives TTC judgments. Other evidence has shown that heuristic-based cues are used, including final optical size or final sound pressure level. Most previous studies have used decontextualized and unfamiliar stimuli (e.g., geometric shapes on a blank background). Here we evaluated TTC estimates by using a traffic scene with an approaching vehicle to evaluate the weights of visual and auditory TTC cues under more realistic conditions. Younger (18-39 years) and older (65+ years) participants made TTC estimates in three sensory conditions: visual-only, auditory-only, and audio-visual. Stimuli were presented within an immersive virtual-reality environment, and cue weights were calculated for both visual cues (e.g., visual τ, final optical size) and auditory cues (e.g., auditory τ, final sound pressure level). The results demonstrated the use of visual τ as well as heuristic cues in the visual-only condition. TTC estimates in the auditory-only condition, however, were primarily based on an auditory heuristic cue (final sound pressure level), rather than on auditory τ. In the audio-visual condition, the visual cues dominated overall, with the highest weight being assigned to visual τ by younger adults, and a more equal weighting of visual τ and heuristic cues in older adults. Overall, better characterizing the effects of combined sensory inputs, stimulus characteristics, and age on the cues used to estimate TTC will provide important insights into how these factors may affect everyday behavior.
Gebauer, Konstanze; Scharf, Thomas; Baumann, Uwe; Groneberg, David A.; Bundschuh, Matthias
2016-01-01
Background: Although noise is one of the leading work-related health risk factors for teachers, many nursery schools lack sufficient noise reduction measures. Methods: This intervention study evaluated the noise exposure of nursery school teachers when dropping DUPLO toy bricks into storage cases. Sound analyses of the impact included assessment of the maximum sound pressure level (LAFmax) as well as frequency analyses with 1/3 octave band filter. For the purpose of standardization, a customized gadget was developed. Recordings were performed in 11 cases of different materials and designs to assess the impact on sound level reduction. Thereby, the acoustic effects of three damping materials (foam rubber, carpet, and PU-foam) were investigated. Results: The lowest LAFmax was measured in cases consisting of “metal grid” (90.71 dB) or of a woven willow “basket” (91.61 dB), whereas a case of “aluminium” (103.34 dB) generated the highest impact LAFmax. The frequency analyses determined especially low LAFmax in the frequency bands between 80 and 2500 Hz in cases designs “metal grid” and “basket”. The insertion of PU-foam achieved the most significant attenuation of LAFmax (−13.88 dB) and, in the frequency analyses, the best sound damping. Conclusion: The dropping of DUPLO bricks in cases contributes to the high noise level in nursery schools, but measured LAFmax show no evidence for the danger of acute hearing loss. However, continuous exposure may lead to functional impairment of the hair cells and trigger stress reactions. We recommend noise reduction by utilizing cases of woven “basket” with an insert of PU-foam. PMID:27384575
Gebauer, Konstanze; Scharf, Thomas; Baumann, Uwe; Groneberg, David A; Bundschuh, Matthias
2016-07-04
Although noise is one of the leading work-related health risk factors for teachers, many nursery schools lack sufficient noise reduction measures. This intervention study evaluated the noise exposure of nursery school teachers when dropping DUPLO toy bricks into storage cases. Sound analyses of the impact included assessment of the maximum sound pressure level (LAFmax) as well as frequency analyses with 1/3 octave band filter. For the purpose of standardization, a customized gadget was developed. Recordings were performed in 11 cases of different materials and designs to assess the impact on sound level reduction. Thereby, the acoustic effects of three damping materials (foam rubber, carpet, and PU-foam) were investigated. The lowest LAFmax was measured in cases consisting of "metal grid" (90.71 dB) or of a woven willow "basket" (91.61 dB), whereas a case of "aluminium" (103.34 dB) generated the highest impact LAFmax. The frequency analyses determined especially low LAFmax in the frequency bands between 80 and 2500 Hz in cases designs "metal grid" and "basket". The insertion of PU-foam achieved the most significant attenuation of LAFmax (-13.88 dB) and, in the frequency analyses, the best sound damping. The dropping of DUPLO bricks in cases contributes to the high noise level in nursery schools, but measured LAFmax show no evidence for the danger of acute hearing loss. However, continuous exposure may lead to functional impairment of the hair cells and trigger stress reactions. We recommend noise reduction by utilizing cases of woven "basket" with an insert of PU-foam.
Yu, Lei; Kang, Jian
2009-09-01
This research aims to explore the feasibility of using computer-based models to predict the soundscape quality evaluation of potential users in urban open spaces at the design stage. With the data from large scale field surveys in 19 urban open spaces across Europe and China, the importance of various physical, behavioral, social, demographical, and psychological factors for the soundscape evaluation has been statistically analyzed. Artificial neural network (ANN) models have then been explored at three levels. It has been shown that for both subjective sound level and acoustic comfort evaluation, a general model for all the case study sites is less feasible due to the complex physical and social environments in urban open spaces; models based on individual case study sites perform well but the application range is limited; and specific models for certain types of location/function would be reliable and practical. The performance of acoustic comfort models is considerably better than that of sound level models. Based on the ANN models, soundscape quality maps can be produced and this has been demonstrated with an example.
Analysis and evaluation of soundscapes in public parks through interviews and measurement of noise.
Szeremeta, Bani; Zannin, Paulo Henrique Trombetta
2009-12-01
The purpose of this work was to investigate the sound environment of public parks using a soundscape study model that analyzes not only noise but also all the types of sound of a given area, as well as other environmental factors. To this end, acoustic measurements were made in the parks under study and interviews were held with their frequent visitors. Noise measurements were conducted in 55 points, and a total of 335 people were interviewed in the 4 parks studied. The parks selected for this study are located in areas very close to streets with intense vehicle flow, raising the hypothesis that this proximity impairs the acoustic comfort of their visitors. The findings confirm the strong influence of traffic noise on the soundscapes of the parks. Noise measurements showed that in all parks, between 50 and 100% of the points evaluated displayed sound levels above 55dB(A), the level established by Curitiba's Municipal Law 10625 as the limit permitted for green areas during daytime. Other conditions in the parks' environments were also identified, which interfere jointly in the soundscape and in its perception, such as spatial factors of each park, the urban setting of its surroundings, and the sounds originating inside the parks.
Acoustic holography: Problems associated with construction and reconstruction techniques
NASA Technical Reports Server (NTRS)
Singh, J. J.
1978-01-01
The implications of the difference between the inspecting and interrogating radiations are discussed. For real-time, distortionless, sound viewing, it is recommended that infrared radiation of wavelength comparable to the inspecting sound waves be used. The infrared images can be viewed with (IR visible) converter phosphors. The real-time display of the visible image of the acoustically-inspected object at low sound levels such as are used in medical diagnosis is evaluated. In this connection attention is drawn to the need for a phosphor screen which is such that its optical transmission at any point is directly related to the incident electron beam intensity at that point. Such a screen, coupled with an acoustical camera, can enable instantaneous sound wave reconstruction.
Duke, Mila Morais; Wolfe, Jace; Schafer, Erin
2016-05-01
Cochlear implant (CI) recipients often experience difficulty understanding speech in noise and speech that originates from a distance. Many CI recipients also experience difficulty understanding speech originating from a television. Use of hearing assistance technology (HAT) may improve speech recognition in noise and for signals that originate from more than a few feet from the listener; however, there are no published studies evaluating the potential benefits of a wireless HAT designed to deliver audio signals from a television directly to a CI sound processor. The objective of this study was to compare speech recognition in quiet and in noise of CI recipients with the use of their CI alone and with the use of their CI and a wireless HAT (Cochlear Wireless TV Streamer). A two-way repeated measures design was used to evaluate performance differences obtained in quiet and in competing noise (65 dBA) with the CI sound processor alone and with the sound processor coupled to the Cochlear Wireless TV Streamer. Sixteen users of Cochlear Nucleus 24 Freedom, CI512, and CI422 implants were included in the study. Participants were evaluated in four conditions including use of the sound processor alone and use of the sound processor with the wireless streamer in quiet and in the presence of competing noise at 65 dBA. Speech recognition was evaluated in each condition with two full lists of Computer-Assisted Speech Perception Testing and Training Sentence-Level Test sentences presented from a light-emitting diode television. Speech recognition in noise was significantly better with use of the wireless streamer compared to participants' performance with their CI sound processor alone. There was also a nonsignificant trend toward better performance in quiet with use of the TV Streamer. Performance was significantly poorer when evaluated in noise compared to performance in quiet when the TV Streamer was not used. Use of the Cochlear Wireless TV Streamer designed to stream audio from a television directly to a CI sound processor provides better speech recognition in quiet and in noise when compared to performance obtained with use of the CI sound processor alone. American Academy of Audiology.
The assessment and evaluation of low-frequency noise near the region of infrasound.
Ziaran, Stanislav
2014-01-01
The main aim of this paper is to present recent knowledge about the assessment and evaluation of low-frequency sounds (noise) and infrasound, close to the threshold of hearing, and identify their potential effect on human health and annoyance. Low-frequency noise generated by air flowing over a moving car with an open window was chosen as a typical scenario which can be subjectively assessed by people traveling by automobile. The principle of noise generated within the interior of the car and its effects on the comfort of the driver and passengers are analyzed at different velocities. An open window of a car at high velocity behaves as a source of specifically strong tonal low-frequency noise which is generally perceived as annoying. The interior noise generated by an open window of a passenger car was measured under different conditions: Driving on a highway and driving on a typical roadway. First, an octave-band analysis was used to assess the noise level and its impact on the driver's comfort. Second, a fast Fourier transform (FFT) analysis and one-third octave-band analysis were used for the detection of tonal low-frequency noise. Comparison between two different car makers was also done. Finally, the paper suggests some possibilities for scientifically assessing and evaluating low-frequency sounds in general, and some recommendations are introduced for scientific discussion, since sounds with strong low-frequency content (but not only strong) engender greater annoyance than is predicted by an A-weighted sound pressure level.
Salavitabar, Arash; Haidet, Kim Kopenhaver; Adkins, Cherie S; Susman, Elizabeth J; Palmer, Charles; Storm, Hanne
2010-06-01
To evaluate the utility of skin conductance (SC) as a measure of autonomic arousal to sound stimuli in preterm infants. A pilot cross-sectional, correlations study. Eleven preterm infants with a mean gestational age of 31.6 weeks without anomalies or conditions associated with neurodevelopmental delay composed the sample. On days 5-7 of life, the following infant responses were simultaneously recorded in response to naturally occurring sound stimuli in the NICU: real-time measurements of heart rate, respiratory rate, and oxygen saturations; sympathetic-mediated sweating via SC; and behavioral responses using the Newborn Individualized Developmental Care and Assessment Program naturalistic observation. Baseline sound levels (BSL, <55 dBA) and high sound levels (HSL, >65 dBA) were measured to index patterns of response during a nonhandling period preceding care. Mean heart rate during precare was directly associated with higher SC increases to sound stimuli (r[10] = 0.697, P = .017). The SC during HSL was significantly higher than that during BSL (P < .0001). Males demonstrated higher SC increases to sound stimuli than females (P = .030). Changes in SC induced by increases in sound intensity were associated with lower attention responses (r[10] = -0.92, P < .0001) and lower summated behavioral responses (r[10] = -0.59, P = .054). SC provides a noninvasive, sensitive measure of sympathetic arousal that may not be apparent in behavioral cues or states, or determined by standard physiological responses alone.
Tomblin, J. Bruce; Peng, Shu-Chen; Spencer, Linda J.; Lu, Nelson
2011-01-01
Purpose This study characterized the development of speech sound production in prelingually deaf children with a minimum of 8 years of cochlear implant (CI) experience. Method Twenty-seven pediatric CI recipients' spontaneous speech samples from annual evaluation sessions were phonemically transcribed. Accuracy for these speech samples was evaluated in piecewise regression models. Results As a group, pediatric CI recipients showed steady improvement in speech sound production following implantation, but the improvement rate declined after 6 years of device experience. Piecewise regression models indicated that the slope estimating the participants' improvement rate was statistically greater than 0 during the first 6 years postimplantation, but not after 6 years. The group of pediatric CI recipients' accuracy of speech sound production after 4 years of device experience reasonably predicts their speech sound production after 5–10 years of device experience. Conclusions The development of speech sound production in prelingually deaf children stabilizes after 6 years of device experience, and typically approaches a plateau by 8 years of device use. Early growth in speech before 4 years of device experience did not predict later rates of growth or levels of achievement. However, good predictions could be made after 4 years of device use. PMID:18695018
Urban Noise Recorded by Stationary Monitoring Stations
NASA Astrophysics Data System (ADS)
Bąkowski, Andrzej; Radziszewski, Leszek; Dekýš, Vladimir
2017-10-01
The paper presents the analysis results of equivalent sound level recorded by two road traffic noise monitoring stations. The stations were located in Kielce (an example of a medium-size town in Poland) at the roads in the town in the direction of Łódź and Lublin. The measurements were carried out through stationary stations monitoring the noise and traffic of motor vehicles. The RMS values based on A-weighted sound level were recorded every 1 s in the buffer and the results were registered every 1 min over the period of investigations. The registered data were the basis for calculating the equivalent sound level for three time intervals: from 6:00 to 18:00, from 18:00 to 22:00 and from 22:00 to 6:00. Analysis included the values of the equivalent sound level recorded for different days of the week split into 24h periods, nights, days and evenings. The data analysed included recordings from 2013. The agreement of the distribution of the variable under analysis with normal distribution was evaluated. It was demonstrated that in most cases (for both roads) there was sufficient evidence to reject the null hypothesis at the significance level of 0.05. It was noted that compared with Łódź Road, in the case of Lublin Road data, more cases were recorded for which the null hypothesis could not be rejected. Uncertainties of the equivalent sound level measurements were compared within the periods under analysis. The standard deviation, coefficient of variation, the positional coefficient of variation, the quartile deviation was proposed for performing a comparative analysis of the obtained data scattering. The investigations indicated that the recorded data varied depending on the traffic routes and time intervals. The differences concerned the values of uncertainties and coefficients of variation of the equivalent sound levels.
Code of Federal Regulations, 2011 CFR
2011-10-01
... second or less. Decibel (dB) means a unit of measurement of sound pressure levels. dB(A) means the sound... operate similar equipment under similar conditions. Sound level or Sound pressure level means ten times... an eight-hour time-weighted-average sound level (TWA) of 85 dB(A), or, equivalently, a dose of 50...
Yoon, Sung Hoon; Nam, Kyoung Won; Yook, Sunhyun; Cho, Baek Hwan; Jang, Dong Pyo; Hong, Sung Hwa; Kim, In Young
2017-03-01
In an effort to improve hearing aid users' satisfaction, recent studies on trainable hearing aids have attempted to implement one or two environmental factors into training. However, it would be more beneficial to train the device based on the owner's personal preferences in a more expanded environmental acoustic conditions. Our study aimed at developing a trainable hearing aid algorithm that can reflect the user's individual preferences in a more extensive environmental acoustic conditions (ambient sound level, listening situation, and degree of noise suppression) and evaluated the perceptual benefit of the proposed algorithm. Ten normal hearing subjects participated in this study. Each subjects trained the algorithm to their personal preference and the trained data was used to record test sounds in three different settings to be utilized to evaluate the perceptual benefit of the proposed algorithm by performing the Comparison Mean Opinion Score test. Statistical analysis revealed that of the 10 subjects, four showed significant differences in amplification constant settings between the noise-only and speech-in-noise situation ( P <0.05) and one subject also showed significant difference between the speech-only and speech-in-noise situation ( P <0.05). Additionally, every subject preferred different β settings for beamforming in all different input sound levels. The positive findings from this study suggested that the proposed algorithm has potential to improve hearing aid users' personal satisfaction under various ambient situations.
Cramp, P; Derksen, F J; Stick, J A; Nickels, F A; Brown, K E; Robinson, P; Robinson, N E
2009-11-01
Little is known about the efficacy of bilateral ventriculectomy (VE) or bilateral ventriculocordectomy (VCE) in draught horses. To compare the effect of VE and VCE on upper airway noise in draught horses with recurrent laryngeal neuropathy (RLN) by use of quantitative sound analysis techniques. In competitive draught horses with grade 4 RLN, VE and VCE reduce upper airway noise during exercise, but VCE is more effective. Thirty competitive hitch or pulling draught horses with grade 4 RLN were evaluated for upper airway sound during exercise. Respiratory rate (RR), inspiratory (Ti) and expiratory time (Te), the ratio between Ti and Te (Ti/Te), inspiratory (Sli) and expiratory sound levels (Sle), the ratio between Sli and Sle (Sli/Sle), and peak sound intensity of the second formant (F2) were calculated. Eleven horses were treated with VE and 19 with VCE. After 90 days of voice and physical rest and 30 days of work, the horses returned for post operative upper airway sound evaluation and resting videoendoscopy. VE significantly reduced Ti/Te, Sli, Sli/Sle and the sound intensity of F2. Respiratory rate, Ti, Te and Sle were unaffected by VE. VCE significantly reduced Ti/Te, Ti, Te, Sli, Sli/Sle and the sound intensity of F2, while RR and Sle were unaffected. The reduction in sound intensity of F2 following VCE was significantly greater than following VE. After VE and VCE, 7/11 (64%) and 15/18 (83%) owners, respectively, concluded that the surgery improved upper airway sound in their horses sufficiently for successful competition. VE and VCE significantly reduce upper airway noise and indices of airway obstruction in draught horses with RLN, but VCE is more effective than VE. The procedures have few post operative complications. VCE is recommended as the preferred treatment for RLN in draught horses. Further studies are required to evaluate the longevity of the procedure's results.
Excessive exposure of sick neonates to sound during transport
Buckland, L; Austin, N; Jackson, A; Inder, T
2003-01-01
Objective: To determine the levels of sound to which infants are exposed during routine transport by ambulance, aircraft, and helicopter. Design: Sound levels during 38 consecutive journeys from a regional level III neonatal intensive care unit were recorded using a calibrated data logging sound meter (Quest 2900). The meter was set to record "A" weighted slow response integrated sound levels, which emulates the response of the human ear, and "C" weighted response sound levels as a measure of total sound level exposure for all frequencies. The information was downloaded to a computer using MS HyperTerminal. The resulting data were stored, and a graphical profile was generated for each journey using SigmaPlot software. Setting: Eight journeys involved ambulance transport on country roads, 24 involved fixed wing aircraft, and four were by helicopter. Main outcome measures: Relations between decibel levels and events or changes in transport mode were established by correlating the time logged on the sound meter with the standard transport documentation sheet. Results: The highest sound levels were recorded during air transport. However, mean sound levels for all modes of transport exceeded the recommended levels for neonatal intensive care. The maximum sound levels recorded were extremely high at greater than 80 dB in the "A" weighted hearing range and greater than 120 dB in the total frequency range. Conclusions: This study raises major concerns about the excessive exposure of the sick newborn to sound during transportation. PMID:14602701
Sound level exposure of high-risk infants in different environmental conditions.
Byers, Jacqueline F; Waugh, W Randolph; Lowman, Linda B
2006-01-01
To provide descriptive information about the sound levels to which high-risk infants are exposed in various actual environmental conditions in the NICU, including the impact of physical renovation on sound levels, and to assess the contributions of various types of equipment, alarms, and activities to sound levels in simulated conditions in the NICU. Descriptive and comparative design. Convenience sample of 134 infants at a southeastern quarternary children's hospital. A-weighted decibel (dBA) sound levels under various actual and simulated environmental conditions. The renovated NICU was, on average, 4-6 dBA quieter across all environmental conditions than a comparable nonrenovated room, representing a significant sound level reduction. Sound levels remained above consensus recommendations despite physical redesign and staff training. Respiratory therapy equipment, alarms, staff talking, and infant fussiness contributed to higher sound levels. Evidence-based sound-reducing strategies are proposed. Findings were used to plan environment management as part of a developmental, family-centered care, performance improvement program and in new NICU planning.
Salomons, Erik M.; Lohman, Walter J. A.; Zhou, Han
2016-01-01
Propagation of sound waves in air can be considered as a special case of fluid dynamics. Consequently, the lattice Boltzmann method (LBM) for fluid flow can be used for simulating sound propagation. In this article application of the LBM to sound propagation is illustrated for various cases: free-field propagation, propagation over porous and non-porous ground, propagation over a noise barrier, and propagation in an atmosphere with wind. LBM results are compared with solutions of the equations of acoustics. It is found that the LBM works well for sound waves, but dissipation of sound waves with the LBM is generally much larger than real dissipation of sound waves in air. To circumvent this problem it is proposed here to use the LBM for assessing the excess sound level, i.e. the difference between the sound level and the free-field sound level. The effect of dissipation on the excess sound level is much smaller than the effect on the sound level, so the LBM can be used to estimate the excess sound level for a non-dissipative atmosphere, which is a useful quantity in atmospheric acoustics. To reduce dissipation in an LBM simulation two approaches are considered: i) reduction of the kinematic viscosity and ii) reduction of the lattice spacing. PMID:26789631
Salomons, Erik M; Lohman, Walter J A; Zhou, Han
2016-01-01
Propagation of sound waves in air can be considered as a special case of fluid dynamics. Consequently, the lattice Boltzmann method (LBM) for fluid flow can be used for simulating sound propagation. In this article application of the LBM to sound propagation is illustrated for various cases: free-field propagation, propagation over porous and non-porous ground, propagation over a noise barrier, and propagation in an atmosphere with wind. LBM results are compared with solutions of the equations of acoustics. It is found that the LBM works well for sound waves, but dissipation of sound waves with the LBM is generally much larger than real dissipation of sound waves in air. To circumvent this problem it is proposed here to use the LBM for assessing the excess sound level, i.e. the difference between the sound level and the free-field sound level. The effect of dissipation on the excess sound level is much smaller than the effect on the sound level, so the LBM can be used to estimate the excess sound level for a non-dissipative atmosphere, which is a useful quantity in atmospheric acoustics. To reduce dissipation in an LBM simulation two approaches are considered: i) reduction of the kinematic viscosity and ii) reduction of the lattice spacing.
Sound pressure level in a municipal preschool
Kemp, Adriana Aparecida Tahara; Delecrode, Camila Ribas; Guida, Heraldo Lorena; Ribeiro, André Knap; Cardoso, Ana Claúdia Vieira
2013-01-01
Summary Aim: To evaluate the sound pressure level to which preschool students are exposed. Method: This was a prospective, quantitative, nonexperimental, and descriptive study. To achieve the aim of the study we used an audio dosimeter. The sound pressure level (SPL) measurements were obtained for 2 age based classrooms. Preschool I and II. The measurements were obtained over 4 days in 8-hour sessions, totaling 1920 minutes. Results: Compared with established standards, the SPL measured ranged from 40.6 dB (A) to 105.8 dB (A). The frequency spectrum of the SPL was concentrated in the frequency range between 500 Hz and 4000 Hz. The older children produced higher SPLs than the younger ones, and the levels varied according to the activity performed. Painting and writing were the quietest activities, while free activities period and games were the noisiest. Conclusion: The SPLs measured at the preschool were higher and exceeded the maximum permitted level according to the reference standards. Therefore, the implementation of actions that aim to minimize the negative impact of noise in this environment is essential. PMID:25992013
L-type calcium channels refine the neural population code of sound level
Grimsley, Calum Alex; Green, David Brian
2016-01-01
The coding of sound level by ensembles of neurons improves the accuracy with which listeners identify how loud a sound is. In the auditory system, the rate at which neurons fire in response to changes in sound level is shaped by local networks. Voltage-gated conductances alter local output by regulating neuronal firing, but their role in modulating responses to sound level is unclear. We tested the effects of L-type calcium channels (CaL: CaV1.1–1.4) on sound-level coding in the central nucleus of the inferior colliculus (ICC) in the auditory midbrain. We characterized the contribution of CaL to the total calcium current in brain slices and then examined its effects on rate-level functions (RLFs) in vivo using single-unit recordings in awake mice. CaL is a high-threshold current and comprises ∼50% of the total calcium current in ICC neurons. In vivo, CaL activates at sound levels that evoke high firing rates. In RLFs that increase monotonically with sound level, CaL boosts spike rates at high sound levels and increases the maximum firing rate achieved. In different populations of RLFs that change nonmonotonically with sound level, CaL either suppresses or enhances firing at sound levels that evoke maximum firing. CaL multiplies the gain of monotonic RLFs with dynamic range and divides the gain of nonmonotonic RLFs with the width of the RLF. These results suggest that a single broad class of calcium channels activates enhancing and suppressing local circuits to regulate the sensitivity of neuronal populations to sound level. PMID:27605536
Noise in a Laboratory Animal Facility from the Human and Mouse Perspectives
Reynolds, Randall P; Kinard, Will L; Degraff, Jesse J; Leverage, Ned; Norton, John N
2010-01-01
The current study was performed to understand the level of sound produced by ventilated racks, animal transfer stations, and construction equipment that mice in ventilated cages hear relative to what humans would hear in the same environment. Although the ventilated rack and animal transfer station both produced sound pressure levels above the ambient level within the human hearing range, the sound pressure levels within the mouse hearing range did not increase above ambient noise from either noise source. When various types of construction equipment were used 3 ft from the ventilated rack, the sound pressure level within the mouse hearing range was increased but to a lesser degree for each implement than were the sound pressure levels within the human hearing range. At more distant locations within the animal facility, sound pressure levels from the large jackhammer within the mouse hearing range decreased much more rapidly than did those in the human hearing range, indicating that less of the sound is perceived by mice than by humans. The relatively high proportion of low-frequency sound produced by the shot blaster, used without the metal shot that it normally uses to clean concrete, increased the sound pressure level above the ambient level for humans but did not increase sound pressure levels above ambient noise for mice at locations greater than 3 ft from inside of the cage, where sound was measured. This study demonstrates that sound clearly audible to humans in the animal facility may be perceived to a lesser degree or not at all by mice, because of the frequency content of the sound. PMID:20858361
Evaluation of a multi-channel algorithm for reducing transient sounds.
Keshavarzi, Mahmoud; Baer, Thomas; Moore, Brian C J
2018-05-15
The objective was to evaluate and select appropriate parameters for a multi-channel transient reduction (MCTR) algorithm for detecting and attenuating transient sounds in speech. In each trial, the same sentence was played twice. A transient sound was presented in both sentences, but its level varied across the two depending on whether or not it had been processed by the MCTR and on the "strength" of the processing. The participant indicated their preference for which one was better and by how much in terms of the balance between the annoyance produced by the transient and the audibility of the transient (they were told that the transient should still be audible). Twenty English-speaking participants were tested, 10 with normal hearing and 10 with mild-to-moderate hearing-impairment. Frequency-dependent linear amplification was provided for the latter. The results for both participant groups indicated that sounds processed using the MCTR were preferred over the unprocessed sounds. For the hearing-impaired participants, the medium and strong settings of the MCTR were preferred over the weak setting. The medium and strong settings of the MCTR reduced the annoyance produced by the transients while maintaining their audibility.
Developing a Weighted Measure of Speech Sound Accuracy
Preston, Jonathan L.; Ramsdell, Heather L.; Oller, D. Kimbrough; Edwards, Mary Louise; Tobin, Stephen J.
2010-01-01
Purpose The purpose is to develop a system for numerically quantifying a speaker’s phonetic accuracy through transcription-based measures. With a focus on normal and disordered speech in children, we describe a system for differentially weighting speech sound errors based on various levels of phonetic accuracy with a Weighted Speech Sound Accuracy (WSSA) score. We then evaluate the reliability and validity of this measure. Method Phonetic transcriptions are analyzed from several samples of child speech, including preschoolers and young adolescents with and without speech sound disorders and typically developing toddlers. The new measure of phonetic accuracy is compared to existing measures, is used to discriminate typical and disordered speech production, and is evaluated to determine whether it is sensitive to changes in phonetic accuracy over time. Results Initial psychometric data indicate that WSSA scores correlate with other measures of phonetic accuracy as well as listeners’ judgments of severity of a child’s speech disorder. The measure separates children with and without speech sound disorders. WSSA scores also capture growth in phonetic accuracy in toddler’s speech over time. Conclusion Results provide preliminary support for the WSSA as a valid and reliable measure of phonetic accuracy in children’s speech. PMID:20699344
Assessment of sound levels in a neonatal intensive care unit in tabriz, iran.
Valizadeh, Sousan; Bagher Hosseini, Mohammad; Alavi, Nasrinsadat; Asadollahi, Malihe; Kashefimehr, Siamak
2013-03-01
High levels of sound have several negative effects, such as noise-induced hearing loss and delayed growth and development, on premature infants in neonatal intensive care units (NICUs). In order to reduce sound levels, they should first be measured. This study was performed to assess sound levels and determine sources of noise in the NICU of Alzahra Teaching Hospital (Tabriz, Iran). In a descriptive study, 24 hours in 4 workdays were randomly selected. Equivalent continuous sound level (Leq), sound level that is exceeded only 10% of the time (L10), maximum sound level (Lmax), and peak instantaneous sound pressure level (Lzpeak) were measured by CEL-440 sound level meter (SLM) at 6 fixed locations in the NICU. Data was collected using a questionnaire. SPSS13 was then used for data analysis. Mean values of Leq, L10, and Lmax were determined as 63.46 dBA, 65.81 dBA, and 71.30 dBA, respectively. They were all higher than standard levels (Leq < 45 dB, L10 ≤50 dB, and Lmax ≤65 dB). The highest Leq was measured at the time of nurse rounds. Leq was directly correlated with the number of staff members present in the ward. Finally, sources of noise were ordered based on their intensity. Considering that sound levels were higher than standard levels in our studied NICU, it is necessary to adopt policies to reduce sound.
Assessment of Sound Levels in a Neonatal Intensive Care Unit in Tabriz, Iran
Valizadeh, Sousan; Bagher Hosseini, Mohammad; Alavi, Nasrinsadat; Asadollahi, Malihe; Kashefimehr, Siamak
2013-01-01
Introduction: High levels of sound have several negative effects, such as noise-induced hearing loss and delayed growth and development, on premature infants in neonatal intensive care units (NICUs). In order to reduce sound levels, they should first be measured. This study was performed to assess sound levels and determine sources of noise in the NICU of Alzahra Teaching Hospital (Tabriz, Iran). Methods: In a descriptive study, 24 hours in 4 workdays were randomly selected. Equivalent continuous sound level (Leq), sound level that is exceeded only 10% of the time (L10), maximum sound level (Lmax), and peak instantaneous sound pressure level (Lzpeak) were measured by CEL-440 sound level meter (SLM) at 6 fixed locations in the NICU. Data was collected using a questionnaire. SPSS13 was then used for data analysis. Results: Mean values of Leq, L10, and Lmax were determined as 63.46 dBA, 65.81 dBA, and 71.30 dBA, respectively. They were all higher than standard levels (Leq < 45 dB, L10 ≤50 dB, and Lmax ≤65 dB). The highest Leq was measured at the time of nurse rounds. Leq was directly correlated with the number of staff members present in the ward. Finally, sources of noise were ordered based on their intensity. Conclusion: Considering that sound levels were higher than standard levels in our studied NICU, it is necessary to adopt policies to reduce sound. PMID:25276706
Laboratory studies of scales for measuring helicopter noise
NASA Technical Reports Server (NTRS)
Ollerhead, J. B.
1982-01-01
The adequacy of the effective perceived noise level (EPNL) procedure for rating helicopter noise annoyance was investigated. Recordings of 89 helicopters and 30 fixed wing aircraft (CTOL) flyover sounds were rated with respect to annoyance by groups of approximately 40 subjects. The average annoyance scores were transformed to annoyance levels defined as the equally annoying sound levels of a fixed reference sound. The sound levels of the test sounds were measured on various scales, with and without corrections for duration, tones, and impulsiveness. On average, the helicopter sounds were judged equally annoying to CTOL sounds when their duration corrected levels are approximately 2 dB higher. Multiple regression analysis indicated that, provided the helicopter/CTOL difference of about 2 dB is taken into account, the particular linear combination of level, duration, and tone corrections inherent in EPNL is close to optimum. The results reveal no general requirement for special EPNL correction terms to penalize helicopter sounds which are particularly impulsive; impulsiveness causes spectral and temporal changes which themselves adequately amplify conventionally measured sound levels.
Performance on Tests of Central Auditory Processing by Individuals Exposed to High-Intensity Blasts
2012-07-01
percent (gap detected on at least four of the six presentations), with all longer durations receiving a score greater than 50 percent. Binaural ...Processing and Sound Localization Temporal precision of neural firing is also involved in binaural processing and localization of sound in space. The...Masking Level Difference (MLD) test evaluates the integrity of the earliest sites of binaural comparison and sensitivity to interaural phase in the
ERIC Educational Resources Information Center
Blackman, Graham A.; Hall, Deborah A.
2011-01-01
Purpose: The intense sound generated during functional magnetic resonance imaging (fMRI) complicates studies of speech and hearing. This experiment evaluated the benefits of using active noise cancellation (ANC), which attenuates the level of the scanner sound at the participant's ear by up to 35 dB around the peak at 600 Hz. Method: Speech and…
Ruhland, Janet L.; Yin, Tom C. T.; Tollin, Daniel J.
2013-01-01
Sound localization accuracy in elevation can be affected by sound spectrum alteration. Correspondingly, any stimulus manipulation that causes a change in the peripheral representation of the spectrum may degrade localization ability in elevation. The present study examined the influence of sound duration and level on localization performance in cats with the head unrestrained. Two cats were trained using operant conditioning to indicate the apparent location of a sound via gaze shift, which was measured with a search-coil technique. Overall, neither sound level nor duration had a notable effect on localization accuracy in azimuth, except at near-threshold levels. In contrast, localization accuracy in elevation improved as sound duration increased, and sound level also had a large effect on localization in elevation. For short-duration noise, the performance peaked at intermediate levels and deteriorated at low and high levels; for long-duration noise, this “negative level effect” at high levels was not observed. Simulations based on an auditory nerve model were used to explain the above observations and to test several hypotheses. Our results indicated that neither the flatness of sound spectrum (before the sound reaches the inner ear) nor the peripheral adaptation influences spectral coding at the periphery for localization in elevation, whereas neural computation that relies on “multiple looks” of the spectral analysis is critical in explaining the effect of sound duration, but not level. The release of negative level effect observed for long-duration sound could not be explained at the periphery and, therefore, is likely a result of processing at higher centers. PMID:23657278
Investigation of the tone-burst tube for duct lining attenuation measurement
NASA Technical Reports Server (NTRS)
Soffel, A. R.; Morrow, P. F.
1972-01-01
The tone burst technique makes practical the laboratory evaluation of potential inlet and discharge duct treatments. Tone burst apparatus requires only simple machined parts and standard components. Small, simply made, lining samples are quickly and easily installed in the system. Two small electromagnetric loudspeaker drivers produce peak sound pressure level of over 166 db in the 3-square-inch sample duct. Air pump available in most laboratories can produce air flows of over plus and minus Mach 0.3 in the sample duct. The technique uses short shaped pulses of sound propagated down a progressive wave tube containing the sample duct. The peak pressure level output of the treated duct is compared with the peak pressure level output of a substituted reference duct. The difference between the levels is the attenuation or insertion loss of the treated duct. Evaluations of resonant absorber linings by the tone burst technique check attenuation values predicted by empirical formulas based on full scale ducts.
Von Benda-Beckmann, Alexander M; Wensveen, Paul J; Kvadsheim, Petter H; Lam, Frans-Peter A; Miller, Patrick J O; Tyack, Peter L; Ainslie, Michael A
2014-02-01
Ramp-up or soft-start procedures (i.e., gradual increase in the source level) are used to mitigate the effect of sonar sound on marine mammals, although no one to date has tested whether ramp-up procedures are effective at reducing the effect of sound on marine mammals. We investigated the effectiveness of ramp-up procedures in reducing the area within which changes in hearing thresholds can occur. We modeled the level of sound killer whales (Orcinus orca) were exposed to from a generic sonar operation preceded by different ramp-up schemes. In our model, ramp-up procedures reduced the risk of killer whales receiving sounds of sufficient intensity to affect their hearing. The effectiveness of the ramp-up procedure depended strongly on the assumed response threshold and differed with ramp-up duration, although extending the duration of the ramp up beyond 5 min did not add much to its predicted mitigating effect. The main factors that limited effectiveness of ramp up in a typical antisubmarine warfare scenario were high source level, rapid moving sonar source, and long silences between consecutive sonar transmissions. Our exposure modeling approach can be used to evaluate and optimize mitigation procedures. © 2013 Society for Conservation Biology.
En route noise levels from propfan test assessment airplane
NASA Technical Reports Server (NTRS)
Garber, Donald P.; Willshire, William L., Jr.
1994-01-01
The en route noise test was designed to characterize propagation of propfan noise from cruise altitudes to the ground. In-flight measurements of propfan source levels and directional patterns were made by a chase plane flying in formation with the propfan test assessment (PTA) airplane. Ground noise measurements were taken during repeated flights over a distributed microphone array. The microphone array on the ground was used to provide ensemble-averaged estimates of mean flyover noise levels, establish confidence limits for those means, and measure propagation-induced noise variability. Even for identical nominal cruise conditions, peak sound levels for individual overflights varied substantially about the average, particularly when overflights were performed on different days. Large day-to-day variations in peak level measurements appeared to be caused by large day-to-day differences in propagation conditions and tended to obscure small variations arising from operating conditions. A parametric evaluation of the sensitivity of this prediction method to weather measurement and source level uncertainties was also performed. In general, predictions showed good agreement with measurements. However, the method was unable to predict short-term variability of ensemble-averaged data within individual overflights. Although variations in absorption appear to be the dominant factor in variations of peak sound levels recorded on the ground, accurate predictions of those levels require that a complete description of operational conditions be taken into account. The comprehensive and integrated methods presented in this paper have adequately predicted ground-measured sound levels. On average, peak sound levels were predicted within 3 dB for each of the three different cruise conditions.
NASA Astrophysics Data System (ADS)
Yun, Dong-Un; Lee, Sang-Kwon
2017-06-01
In this paper, we present a novel method for an objective evaluation of knocking noise emitted by diesel engines based on the temporal and frequency masking theory. The knocking sound of a diesel engine is a vibro-acoustic sound correlated with the high-frequency resonances of the engine structure and a periodic impulsive sound with amplitude modulation. Its period is related to the engine speed and includes specific frequency bands related to the resonances of the engine structure. A knocking sound with the characteristics of a high-frequency impulsive wave can be masked by low-frequency sounds correlated with the harmonics of the firing frequency and broadband noise. The degree of modulation of the knocking sound signal was used for such objective evaluations in previous studies, without considering the masking effect. However, the frequency masking effect must be considered for the objective evaluation of the knocking sound. In addition to the frequency masking effect, the temporal masking effect occurs because the period of the knocking sound changes according to the engine speed. Therefore, an evaluation method considering the temporal and frequency masking effect is required to analyze the knocking sound objectively. In this study, an objective evaluation method considering the masking effect was developed based on the masking theory of sound and signal processing techniques. The method was applied successfully for the objective evaluation of the knocking sound of a diesel engine.
Vermeulen, L; Van de Perre, V; Permentier, L; De Bie, S; Verbeke, G; Geers, R
2016-06-01
This study investigates the relationship between sound levels, pre-slaughter handling during loading and pork quality. Pre-slaughter variables were investigated from loading till slaughter. A total of 3213 pigs were measured 30 min post-mortem for pH(30LT) (M. Longissimus thoracis). First, a sound level model for the risk to develop PSE meat was established. The difference in maximum and mean sound level during loading, mean sound level during lairage and mean sound level prior to stunning remained significant within the model. This indicated that sound levels during loading had a significant added value to former sound models. Moreover, this study completed the global classification checklist (Vermeulen et al., 2015a) by developing a linear mixed model for pH(30LT) and PSE prevalence, with the difference in maximum and mean sound level measured during loading, the feed withdrawal period and the difference in temperature during loading and lairage. Hence, this study provided new insights over previous research where loading procedures were not included. Copyright © 2016 Elsevier Ltd. All rights reserved.
L-type calcium channels refine the neural population code of sound level.
Grimsley, Calum Alex; Green, David Brian; Sivaramakrishnan, Shobhana
2016-12-01
The coding of sound level by ensembles of neurons improves the accuracy with which listeners identify how loud a sound is. In the auditory system, the rate at which neurons fire in response to changes in sound level is shaped by local networks. Voltage-gated conductances alter local output by regulating neuronal firing, but their role in modulating responses to sound level is unclear. We tested the effects of L-type calcium channels (Ca L : Ca V 1.1-1.4) on sound-level coding in the central nucleus of the inferior colliculus (ICC) in the auditory midbrain. We characterized the contribution of Ca L to the total calcium current in brain slices and then examined its effects on rate-level functions (RLFs) in vivo using single-unit recordings in awake mice. Ca L is a high-threshold current and comprises ∼50% of the total calcium current in ICC neurons. In vivo, Ca L activates at sound levels that evoke high firing rates. In RLFs that increase monotonically with sound level, Ca L boosts spike rates at high sound levels and increases the maximum firing rate achieved. In different populations of RLFs that change nonmonotonically with sound level, Ca L either suppresses or enhances firing at sound levels that evoke maximum firing. Ca L multiplies the gain of monotonic RLFs with dynamic range and divides the gain of nonmonotonic RLFs with the width of the RLF. These results suggest that a single broad class of calcium channels activates enhancing and suppressing local circuits to regulate the sensitivity of neuronal populations to sound level. Copyright © 2016 the American Physiological Society.
Numerical Simulation of Noise from Supersonic Jets Passing Through a Rigid Duct
NASA Technical Reports Server (NTRS)
Kandula, Max
2012-01-01
The generation, propagation and radiation of sound from a perfectly expanded Mach 2.5 cold supersonic jet flowing through an enclosed rigid-walled duct with an upstream J-deflector have been numerically simulated with the aid of OVERFLOW Navier-Stokes CFD code. A one-equation turbulence model is considered. While the near-field sound sources are computed by the CFD code, the far-field sound is evaluated by Kirchhoff surface integral formulation. Predictions of the farfield directivity of the OASPL (Overall Sound Pressure Level) agree satisfactorily with the experimental data previously reported by the author. Calculations also suggest that there is significant entrainment of air into the duct, with the mass flow rate of entrained air being about three times the jet exit mass flow rate.
A little bit less would be great: adolescents' opinion towards music levels.
Gilles, Annick; Thuy, Inge; De Rycke, Els; Van de Heyning, Paul
2014-01-01
Many music organizations are opposed to restrictive noise regulations, because of anxiety related to the possibility of a decrease in the number of adolescents attending music events. The present study consists of two research parts evaluating on one hand the youth's attitudes toward the sound levels at indoor as well as outdoor musical activities and on the other hand the effect of more strict noise regulations on the party behavior of adolescents and young adults. In the first research part, an interview was conducted during a music event at a youth club. A total of 41 young adults were questioned concerning their opinion toward the intensity levels of the music twice: Once when the sound level was 98 dB(A), LAeq, 60min and once when the sound level was increased up to 103 dB(A), LAeq, 60min . Some additional questions concerning hearing protection (HP) use and attitudes toward more strict noise regulations were asked. In the second research part, an extended version of the questionnaire, with addition of some questions concerning the reasons for using/not using HP at music events, was published online and completed by 749 young adults. During the interview, 51% considered a level of 103 dB(A), LAeq, 60min too loud compared with 12% during a level of 98 dB(A), LAeq, 60min . For the other questions, the answers were similar for both research parts. Current sound levels at music venues were often considered as too loud. More than 80% held a positive attitude toward more strict noise regulations and reported that they would not alter their party behavior when the sound levels would decrease. The main reasons given for the low use of HP were that adolescents forget to use them, consider them as uncomfortable and that they never even thought about using them. These results suggest that adolescents do not demand excessive noise levels and that more strict noise regulation would not influence party behavior of youngsters.
A noise assessment and prediction system
NASA Technical Reports Server (NTRS)
Olsen, Robert O.; Noble, John M.
1990-01-01
A system has been designed to provide an assessment of noise levels that result from testing activities at Aberdeen Proving Ground, Md. The system receives meteorological data from surface stations and an upper air sounding system. The data from these systems are sent to a meteorological model, which provides forecasting conditions for up to three hours from the test time. The meteorological data are then used as input into an acoustic ray trace model which projects sound level contours onto a two-dimensional display of the surrounding area. This information is sent to the meteorological office for verification, as well as the range control office, and the environmental office. To evaluate the noise level predictions, a series of microphones are located off the reservation to receive the sound and transmit this information back to the central display unit. The computer models are modular allowing for a variety of models to be utilized and tested to achieve the best agreement with data. This technique of prediction and model validation will be used to improve the noise assessment system.
Scattering of sound by atmospheric turbulence predictions in a refractive shadow zone
NASA Technical Reports Server (NTRS)
Mcbride, Walton E.; Bass, Henry E.; Raspet, Richard; Gilbert, Kenneth E.
1990-01-01
According to ray theory, regions exist in an upward refracting atmosphere where no sound should be present. Experiments show, however, that appreciable sound levels penetrate these so-called shadow zones. Two mechanisms contribute to sound in the shadow zone: diffraction and turbulent scattering of sound. Diffractive effects can be pronounced at lower frequencies but are small at high frequencies. In the short wavelength limit, then, scattering due to turbulence should be the predominant mechanism involved in producing the sound levels measured in shadow zones. No existing analytical method includes turbulence effects in the prediction of sound pressure levels in upward refractive shadow zones. In order to obtain quantitative average sound pressure level predictions, a numerical simulation of the effect of atmospheric turbulence on sound propagation is performed. The simulation is based on scattering from randomly distributed scattering centers ('turbules'). Sound pressure levels are computed for many realizations of a turbulent atmosphere. Predictions from the numerical simulation are compared with existing theories and experimental data.
Prediction of light aircraft interior sound pressure level using the room equation
NASA Technical Reports Server (NTRS)
Atwal, M.; Bernhard, R.
1984-01-01
The room equation is investigated for predicting interior sound level. The method makes use of an acoustic power balance, by equating net power flow into the cabin volume to power dissipated within the cabin using the room equation. The sound power level transmitted through the panels was calculated by multiplying the measured space averaged transmitted intensity for each panel by its surface area. The sound pressure level was obtained by summing the mean square sound pressures radiated from each panel. The data obtained supported the room equation model in predicting the cabin interior sound pressure level.
Jeanson, Lena; Wiegrebe, Lutz; Gürkov, Robert; Krause, Eike; Drexl, Markus
2017-02-01
The presentation of intense, low-frequency (LF) sound to the human ear can cause very slow, sinusoidal oscillations of cochlear sensitivity after LF sound offset, coined the "Bounce" phenomenon. Changes in level and frequency of spontaneous otoacoustic emissions (SOAEs) are a sensitive measure of the Bounce. Here, we investigated the effect of LF sound level and frequency on the Bounce. Specifically, the level of SOAEs was tracked for minutes before and after a 90-s LF sound exposure. Trials were carried out with several LF sound levels (93 to 108 dB SPL corresponding to 47 to 75 phons at a fixed frequency of 30 Hz) and different LF sound frequencies (30, 60, 120, 240 and 480 Hz at a fixed loudness level of 80 phons). At an LF sound frequency of 30 Hz, a minimal sound level of 102 dB SPL (64 phons) was sufficient to elicit a significant Bounce. In some subjects, however, 93 dB SPL (47 phons), the lowest level used, was sufficient to elicit the Bounce phenomenon and actual thresholds could have been even lower. Measurements with different LF sound frequencies showed a mild reduction of the Bounce phenomenon with increasing LF sound frequency. This indicates that the strength of the Bounce not only is a simple function of the spectral separation between SOAE and LF sound frequency but also depends on absolute LF sound frequency, possibly related to the magnitude of the AC component of the outer hair cell receptor potential.
Conceptual Soundness, Metric Development, Benchmarking, and Targeting for PATH Subprogram Evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mosey. G.; Doris, E.; Coggeshall, C.
The objective of this study is to evaluate the conceptual soundness of the U.S. Department of Housing and Urban Development (HUD) Partnership for Advancing Technology in Housing (PATH) program's revised goals and establish and apply a framework to identify and recommend metrics that are the most useful for measuring PATH's progress. This report provides an evaluative review of PATH's revised goals, outlines a structured method for identifying and selecting metrics, proposes metrics and benchmarks for a sampling of individual PATH programs, and discusses other metrics that potentially could be developed that may add value to the evaluation process. The frameworkmore » and individual program metrics can be used for ongoing management improvement efforts and to inform broader program-level metrics for government reporting requirements.« less
Developing the Ability for Making Evaluative Judgements
ERIC Educational Resources Information Center
Cowan, John
2010-01-01
It is suggested that a more specific emphasis should be placed in undergraduate education on the explicit development of the ability to make evaluative judgements. This higher level cognitive ability is highlighted as the foundation for much sound and successful personal and professional development throughout education, and in lifelong…
Durai, Mithila; Kobayashi, Kei; Searchfield, Grant D
2018-05-28
To evaluate the feasibility of predictable or unpredictable amplitude-modulated sounds for tinnitus therapy. The study consisted of two parts. (1) An adaptation experiment. Loudness level matches and rating scales (10-point) for loudness and distress were obtained at a silent baseline and at the end of three counterbalanced 30-min exposures (silence, predictable and unpredictable). (2) A qualitative 2-week sound therapy feasibility trial. Participants took home a personal music player (PMP). Part 1: 23 individuals with chronic tinnitus and part 2: seven individuals randomly selected from Part 1. Self-reported tinnitus loudness and annoyance were significantly lower than baseline ratings after acute unpredictable sound exposure. Tinnitus annoyance ratings were also significantly lower than the baseline but the effect was small. The feasibility trial identified that participant preferences for sounds varied. Three participants did not obtain any benefit from either sound. Three participants preferred unpredictable compared to predictable sounds. Some participants had difficulty using the PMP, the average self-report hours of use were low (less <1 h/day). Unpredictable surf-like sounds played using a PMP is a feasible tinnitus treatment. Further work is required to improve the acceptance of the sound and ease of PMP use.
Development and evaluation of a general aviation real world noise simulator
NASA Technical Reports Server (NTRS)
Galanter, E.; Popper, R.
1980-01-01
An acoustic playback system is described which realistically simulates the sounds experienced by the pilot of a general aviation aircraft during engine idle, take-off, climb, cruise, descent, and landing. The physical parameters of the signal as they appear in the simulator environment are compared to analogous parameters derived from signals recorded during actual flight operations. The acoustic parameters of the simulated and real signals during cruise conditions are within plus or minus two dB in third octave bands from 0.04 to 4 kHz. The overall A-weighted levels of the signals are within one dB of signals generated in the actual aircraft during equivalent maneuvers. Psychoacoustic evaluations of the simulator signal are compared with similar measurements based on transcriptions of actual aircraft signals. The subjective judgments made by human observers support the conclusion that the simulated sound closely approximates transcribed sounds of real aircraft.
NASA Astrophysics Data System (ADS)
Kawai, Keiji; Kojima, Takaya; Hirate, Kotaroh; Yasuoka, Masahito
2004-10-01
In this study, we conducted an experiment to investigate the evaluation structure that lies at the basis of peoples' psychological evaluation of environmental sounds. In the experiment, subjects were given cards on each of which a name of one of the environmental sounds in the specified context is written. Then they did the following three tasks: (1) to sort the cards into groups by the similarity of their impressions of the imagined sounds; (2) to name each group with the word that best represented their overall impression of the group; and (3) to evaluate all sounds on the cards using the words obtained in the previous task. These tasks were done twice: once assuming they heard the sounds at ease inside their homes and once while walking outside in a resort theme park. We analysed the similarity of imagined impression between the sounds with a cluster analysis and clusters of sounds were produced, namely, sounds labelled "natural," "transportation," and so on. A principal component analysis revealed the three major factors of the evaluation structure for both contexts and they were interpreted as preference, activity and sense of daily life.
ERIC Educational Resources Information Center
Goehring, Jenny L.; Hughes, Michelle L.
2017-01-01
Purpose: This study evaluated the use of telepractice for measuring cochlear implant (CI) behavioral threshold (T) levels in children using conditioned play audiometry (CPA). The goals were to determine whether (a) T levels measured via telepractice were not significantly different from those obtained in person, (b) response probability differed…
Yamashita, Toshiya; Hayashi, Takashi
2014-05-01
We aimed to examine the effects of reading difficulties on scholastic self-evaluation and mental health in elementary school students. Following guidelines for diagnosing reading disorders in elementary school students, we administered reading test batteries consisting of single sounds, single words, and single sentences to 41 fifth-grade elementary school students in Japan. The students' levels of scholastic self-evaluation, self-esteem, and depressive symptoms were assessed using self-rating questionnaires. By evaluating students' reading speed and the number of reading errors they made, we found that six students (14.6%) had reading difficulties (RD group) as per the guidelines for diagnosing reading disorders. The scholastic self-evaluation scores of this RD group were significantly lower than that of the non-RD group. No significant differences were found between the groups on self-esteem or depressive symptoms scores, which we considered to be indicators of mental health, Speed in reading single sounds and single words, and the number of reading errors in reading single sounds had significant negative correlations with scholastic self-evaluation scores. We found that reading difficulties might result in decreased scholastic self-evaluation in elementary school students; however, reading difficulties did not directly influence self-esteem or depression.
Durai, Mithila; Searchfield, Grant D
2017-01-01
Objectives: A randomized cross-over trial in 18 participants tested the hypothesis that nature sounds, with unpredictable temporal characteristics and high valence would yield greater improvement in tinnitus than constant, emotionally neutral broadband noise. Study Design: The primary outcome measure was the Tinnitus Functional Index (TFI). Secondary measures were: loudness and annoyance ratings, loudness level matches, minimum masking levels, positive and negative emotionality, attention reaction and discrimination time, anxiety, depression and stress. Each sound was administered using MP3 players with earbuds for 8 continuous weeks, with a 3 week wash-out period before crossing over to the other treatment sound. Measurements were undertaken for each arm at sound fitting, 4 and 8 weeks after administration. Qualitative interviews were conducted at each of these appointments. Results: From a baseline TFI score of 41.3, sound therapy resulted in TFI scores at 8 weeks of 35.6; broadband noise resulted in significantly greater reduction (8.2 points) after 8 weeks of sound therapy use than nature sounds (3.2 points). The positive effect of sound on tinnitus was supported by secondary outcome measures of tinnitus, emotion, attention, and psychological state, but not interviews. Tinnitus loudness level match was higher for BBN at 8 weeks; while there was little change in loudness level matches for nature sounds. There was no change in minimum masking levels following sound therapy administration. Self-reported preference for one sound over another did not correlate with changes in tinnitus. Conclusions: Modeled under an adaptation level theory framework of tinnitus perception, the results indicate that the introduction of broadband noise shifts internal adaptation level weighting away from the tinnitus signal, reducing tinnitus magnitude. Nature sounds may modify the affective components of tinnitus via a secondary, residual pathway, but this appears to be less important for sound effectiveness. The different rates of adaptation to broadband noise and nature sound by the auditory system may explain the different tinnitus loudness level matches. In addition to group effects there also appears to be a great deal of individual variation. A sound therapy framework based on adaptation level theory is proposed that accounts for individual variation in preference and response to sound. Clinical Trial Registration: www.anzctr.org.au, identifier #12616000742471.
Durai, Mithila; Searchfield, Grant D.
2017-01-01
Objectives: A randomized cross-over trial in 18 participants tested the hypothesis that nature sounds, with unpredictable temporal characteristics and high valence would yield greater improvement in tinnitus than constant, emotionally neutral broadband noise. Study Design: The primary outcome measure was the Tinnitus Functional Index (TFI). Secondary measures were: loudness and annoyance ratings, loudness level matches, minimum masking levels, positive and negative emotionality, attention reaction and discrimination time, anxiety, depression and stress. Each sound was administered using MP3 players with earbuds for 8 continuous weeks, with a 3 week wash-out period before crossing over to the other treatment sound. Measurements were undertaken for each arm at sound fitting, 4 and 8 weeks after administration. Qualitative interviews were conducted at each of these appointments. Results: From a baseline TFI score of 41.3, sound therapy resulted in TFI scores at 8 weeks of 35.6; broadband noise resulted in significantly greater reduction (8.2 points) after 8 weeks of sound therapy use than nature sounds (3.2 points). The positive effect of sound on tinnitus was supported by secondary outcome measures of tinnitus, emotion, attention, and psychological state, but not interviews. Tinnitus loudness level match was higher for BBN at 8 weeks; while there was little change in loudness level matches for nature sounds. There was no change in minimum masking levels following sound therapy administration. Self-reported preference for one sound over another did not correlate with changes in tinnitus. Conclusions: Modeled under an adaptation level theory framework of tinnitus perception, the results indicate that the introduction of broadband noise shifts internal adaptation level weighting away from the tinnitus signal, reducing tinnitus magnitude. Nature sounds may modify the affective components of tinnitus via a secondary, residual pathway, but this appears to be less important for sound effectiveness. The different rates of adaptation to broadband noise and nature sound by the auditory system may explain the different tinnitus loudness level matches. In addition to group effects there also appears to be a great deal of individual variation. A sound therapy framework based on adaptation level theory is proposed that accounts for individual variation in preference and response to sound. Clinical Trial Registration: www.anzctr.org.au, identifier #12616000742471. PMID:28337139
NASA Technical Reports Server (NTRS)
Theobald, M. A.
1978-01-01
The single source location used for helicopter model studies was utilized in a study to determine the distances and directions upstream of the model accurate at which measurements of the direct acoustic field could be obtained. The method used was to measure the decrease of sound pressure levels with distance from a noise source and thereby determine the Hall radius as a function of frequency and direction. Test arrangements and procedures are described. Graphs show the normalized sound pressure level versus distance curves for the glass fiber floor treatment and for the foam floor treatment.
40 CFR 201.22 - Measurement instrumentation.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Criteria § 201.22 Measurement instrumentation. (a) A sound level meter or alternate sound level measurement...., 1430 Broadway, New York, NY 10018. Table 1—Sound Level Corrections When Using a Type 2 (or S2A... the sound level meter or (2) the manufacturer of the microphone. The choice of both devices must be...
40 CFR 201.22 - Measurement instrumentation.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Criteria § 201.22 Measurement instrumentation. (a) A sound level meter or alternate sound level measurement...., 1430 Broadway, New York, NY 10018. Table 1—Sound Level Corrections When Using a Type 2 (or S2A... the sound level meter or (2) the manufacturer of the microphone. The choice of both devices must be...
Prospective cohort study on noise levels in a pediatric cardiac intensive care unit.
Garcia Guerra, Gonzalo; Joffe, Ari R; Sheppard, Cathy; Pugh, Jodie; Moez, Elham Khodayari; Dinu, Irina A; Jou, Hsing; Hartling, Lisa; Vohra, Sunita
2018-04-01
To describe noise levels in a pediatric cardiac intensive care unit, and to determine the relationship between sound levels and patient sedation requirements. Prospective observational study at a pediatric cardiac intensive care unit (PCICU). Sound levels were measured continuously in slow A weighted decibels dB(A) with a sound level meter SoundEarPro® during a 4-week period. Sedation requirement was assessed using the number of intermittent (PRNs) doses given per hour. Analysis was conducted with autoregressive moving average models and the Granger test for causality. 39 children were included in the study. The average (SD) sound level in the open area was 59.4 (2.5) dB(A) with a statistically significant but clinically unimportant difference between day/night hours (60.1 vs. 58.6; p-value < 0.001). There was no significant difference between sound levels in the open area/single room (59.4 vs. 60.8, p-value = 0.108). Peak noise levels were > 90 dB. There was a significant association between average (p-value = 0.030) and peak sound levels (p-value = 0.006), and number of sedation PRNs. Sound levels were above the recommended values with no differences between day/night or open area/single room. High sound levels were significantly associated with sedation requirements. Copyright © 2017 Elsevier Inc. All rights reserved.
He, Wenxuan; Porsov, Edward; Kemp, David; Nuttall, Alfred L.; Ren, Tianying
2012-01-01
Background It is commonly assumed that the cochlear microphonic potential (CM) recorded from the round window (RW) is generated at the cochlear base. Based on this assumption, the low-frequency RW CM has been measured for evaluating the integrity of mechanoelectrical transduction of outer hair cells at the cochlear base and for studying sound propagation inside the cochlea. However, the group delay and the origin of the low-frequency RW CM have not been demonstrated experimentally. Methodology/Principal Findings This study quantified the intra-cochlear group delay of the RW CM by measuring RW CM and vibrations at the stapes and basilar membrane in gerbils. At low sound levels, the RW CM showed a significant group delay and a nonlinear growth at frequencies below 2 kHz. However, at high sound levels or at frequencies above 2 kHz, the RW CM magnitude increased proportionally with sound pressure, and the CM phase in respect to the stapes showed no significant group delay. After the local application of tetrodotoxin the RW CM below 2 kHz became linear and showed a negligible group delay. In contrast to RW CM phase, the BM vibration measured at location ∼2.5 mm from the base showed high sensitivity, sharp tuning, and nonlinearity with a frequency-dependent group delay. At low or intermediate sound levels, low-frequency RW CMs were suppressed by an additional tone near the probe-tone frequency while, at high sound levels, they were partially suppressed only at high frequencies. Conclusions/Significance We conclude that the group delay of the RW CM provides no temporal information on the wave propagation inside the cochlea, and that significant group delay of low-frequency CMs results from the auditory nerve neurophonic potential. Suppression data demonstrate that the generation site of the low-frequency RW CM shifts from apex to base as the probe-tone level increases. PMID:22470560
NASA Astrophysics Data System (ADS)
Huang, Xianfeng; Meng, Yao; Huang, Riming
2017-10-01
This paper describes a theoretical method for predicting the improvement of the impact sound insulation to a floating floor with the resilient interlayer. Statistical energy analysis (SEA) model, which is skilful in calculating the floor impact sound, is set up for calculating the reduction in impact sound pressure level in downstairs room. The sound transmission paths which include direct path and flanking paths are analyzed to find the dominant one; the factors that affect impact sound reduction for a floating floor are explored. Then, the impact sound level in downstairs room is determined and comparisons between predicted and measured data are conducted. It is indicated that for the impact sound transmission across a floating floor, the flanking path impact sound level contribute tiny influence on overall sound level in downstairs room, and a floating floor with low stiffness interlayer exhibits favorable sound insulation on direct path. The SEA approach applies to the floating floors with resilient interlayers, which are experimentally verified, provides a guidance in sound insulation design.
Sound levels and their effects on children in a German primary school.
Eysel-Gosepath, Katrin; Daut, Tobias; Pinger, Andreas; Lehmacher, Walter; Erren, Thomas
2012-12-01
Considerable sound levels are produced in primary schools by voices of children and resonance effects. As a consequence, hearing loss and mental impairment may occur. In a Cologne primary school, sound levels were measured in three different classrooms, each with 24 children, 8-10 years old, and one teacher. Sound dosimeters were positioned in the room and near the teacher's ear. Additional measurements were done in one classroom fully equipped with sound-absorbing materials. A questionnaire containing 12 questions about noise at school was distributed to 100 children, 8-10 years old. Measurements were repeated after children had been taught about noise damage and while "noise lights" were used. Mean sound levels of 5-h per day measuring period were 78 dB (A) near the teacher's ear and 70 dB (A) in the room. The average of all measured maximal sound levels for 1 s was 105 dB (A) for teachers, and 100 dB (A) for rooms. In the soundproofed classroom, Leq was 66 dB (A). The questionnaire revealed certain judgment of the children concerning situations with high sound levels and their ability to develop ideas for noise reduction. However, no clear sound level reduction was identified after noise education and using "noise lights" during lessons. Children and their teachers are equally exposed to high sound levels at school. Early sensitization to noise and the possible installation of sound-absorbing materials can be important means to prevent noise-associated hearing loss and mental impairment.
Wysocki, L.E.; Davidson, J. W.; Smith, M.E.; Frankel, A.S.; Ellison, W.T.; Mazik, P.M.; Popper, A.N.; Bebak, J.
2007-01-01
Intensive aquaculture production often utilizes equipment (e.g., aerators, air and water pumps, harvesters, blowers, filtration systems, and maintenance machinery) that increases noise levels in fish culture tanks. Consequently, chronic exposure to elevated noise levels in tanks could negatively impact cultured species. Possible effects include impairment of the auditory system, increased stress, and reduced growth rates. The objective of this study was to evaluate the long-term effects of sound exposure on the hearing sensitivity, growth, and survival of cultured rainbow trout (Oncorhynchus mykiss). Two cohorts of rainbow trout were cultured for 8??months in replicated tanks consisting of three sound treatments: 115, 130, or 150 decibels referenced at 1 micropascal (dB re 1????Pa root mean square [RMS]) levels. Auditory evoked potential (AEP) recordings revealed no significant differences in hearing thresholds resulting from exposure to increased ambient sound levels. Although there was no evident noise-induced hearing loss, there were significant differences in hearing thresholds between the two fish cohorts examined. No statistical effect of sound treatment was found for growth rate and mortality within each fish cohort. There was no significant difference in mortality between sound treatments when fish were exposed to the pathogen Yersinia ruckeri, but there was significantly different mortality between cohorts. This study indicated that rainbow trout hearing sensitivity, growth, survival, stress, and disease susceptibility were not negatively impacted by noise levels common to recirculating aquaculture systems. These findings should not be generalized to all cultured fish species, however, because many species, including catfish and cyprinids, have much greater hearing sensitivity than rainbow trout and could be affected differently by noise. ?? 2007 Elsevier B.V. All rights reserved.
Traffic Noise Assessment at Residential Areas in Skudai, Johor
NASA Astrophysics Data System (ADS)
Sulaiman, F. S.; Darus, N.; Mashros, N.; Haron, Z.; Yahya, K.
2018-03-01
Vehicles passing by on roadways in residential areas may produce unpleasant traffic noise that affects the residents. This paper presents the traffic noise assessment of three selected residential areas located in Skudai, Johor. The objectives of this study are to evaluate traffic characteristics at selected residential areas, determine related noise indices, and assess impact of traffic noise. Traffic characteristics such as daily traffic volume and vehicle speed were evaluated using automatic traffic counter (ATC). Meanwhile, noise indices like equivalent continuous sound pressure level (LAeq), noise level exceeded 10% (L10) and 90% (L90) of measurement time were determined using sound level meter (SLM). Besides that, traffic noise index (TNI) and noise pollution level (LNP) were calculated based on the measured noise indices. The results showed an increase in noise level of 60 to 70 dBA maximum due to increase in traffic volume. There was also a significant change in noise level of more than 70 dBA even though average vehicle speed did not vary significantly. Nevertheless, LAeq, TNI, and LNP values for all sites during daytime were lower than the maximum recommended levels. Thus, residents in the three studied areas were not affected in terms of quality of life and health.
Moderate acoustic changes can disrupt the sleep of very preterm infants in their incubators.
Kuhn, Pierre; Zores, Claire; Langlet, Claire; Escande, Benoît; Astruc, Dominique; Dufour, André
2013-10-01
To evaluate the impact of moderate noise on the sleep of very early preterm infants (VPI). Observational study of 26 VPI of 26-31 weeks' gestation, with prospective measurements of sound pressure level and concomitant video records. Sound peaks were identified and classified according to their signal-to-noise ratio (SNR) above background noise. Prechtl's arousal states during sound peaks were assessed by two observers blinded to the purpose of the study. Changes in sleep/arousal states following sound peaks were compared with spontaneous changes during randomly selected periods without sound peaks. We identified 598 isolated sound peaks (5 ≤ SNR < 10 decibel slow response A (dBA), n = 518; 10 ≤ SNR < 15 dBA, n = 80) during sleep. Awakenings were observed during 33.8% (95% CI, 24-43.7%) of exposures to sound peaks of 5-10 dBA SNR and 39.7% (95% CI, 26-53.3%) of exposures to sound peaks of SNR 10-15 dBA, but only 11.7% (95% CI, 6.2-17.1%) of control periods. The proportions of awakenings following sound peaks were higher than the proportions of arousals during control periods (p < 0.005). Moderate acoustic changes can disrupt the sleep of VPI, and efficient sound abatement measures are needed. ©2013 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.
Evaluation of Noise Exposure Secondary to Wind Noise in Cyclists.
Seidman, Michael D; Wertz, Anna G; Smith, Matthew M; Jacob, Steve; Ahsan, Syed F
2017-11-01
Objective Determine if the noise levels of wind exposure experienced by cyclists reach levels that could contribute to noise-induced hearing loss. Study Design Industrial lab research. Setting Industrial wind tunnel. Subjects and Methods A commercial-grade electric wind tunnel was used to simulate different speeds encountered by a cyclist. A single cyclist was used during the simulation for audiometric measurements. Microphones attached near the ears of the cyclist were used to measure the sound (dB sound pressure level) experienced by the cyclist. Loudness levels were measured with the head positioned at 15-degree increments from 0 degrees to 180 degrees relative to the oncoming wind at different speeds (10-60 mph). Results Wind noise ranged from 84.9 dB at 10 mph and increased proportionally with speed to a maximum of 120.3 dB at 60 mph. The maximum of 120.3 dB was measured at the downwind ear when the ear was 90 degrees away from the wind. Conclusions Wind noise experienced by a cyclist is proportional to the speed and the directionality of the wind current. Turbulent air flow patterns are observed that contribute to increased sound exposure in the downwind ear. Consideration of ear deflection equipment without compromising sound awareness for cyclists during prolonged rides is advised to avoid potential noise trauma. Future research is warranted and can include long-term studies including dosimetry measures of the sound and yearly pre- and postexposure audiograms of cyclists to detect if any hearing loss occurs with long-term cycling.
Developing a weighted measure of speech sound accuracy.
Preston, Jonathan L; Ramsdell, Heather L; Oller, D Kimbrough; Edwards, Mary Louise; Tobin, Stephen J
2011-02-01
To develop a system for numerically quantifying a speaker's phonetic accuracy through transcription-based measures. With a focus on normal and disordered speech in children, the authors describe a system for differentially weighting speech sound errors on the basis of various levels of phonetic accuracy using a Weighted Speech Sound Accuracy (WSSA) score. The authors then evaluate the reliability and validity of this measure. Phonetic transcriptions were analyzed from several samples of child speech, including preschoolers and young adolescents with and without speech sound disorders and typically developing toddlers. The new measure of phonetic accuracy was validated against existing measures, was used to discriminate typical and disordered speech production, and was evaluated to examine sensitivity to changes in phonetic accuracy over time. Reliability between transcribers and consistency of scores among different word sets and testing points are compared. Initial psychometric data indicate that WSSA scores correlate with other measures of phonetic accuracy as well as listeners' judgments of the severity of a child's speech disorder. The measure separates children with and without speech sound disorders and captures growth in phonetic accuracy in toddlers' speech over time. The measure correlates highly across transcribers, word lists, and testing points. Results provide preliminary support for the WSSA as a valid and reliable measure of phonetic accuracy in children's speech.
Linear multivariate evaluation models for spatial perception of soundscape.
Deng, Zhiyong; Kang, Jian; Wang, Daiwei; Liu, Aili; Kang, Joe Zhengyu
2015-11-01
Soundscape is a sound environment that emphasizes the awareness of auditory perception and social or cultural understandings. The case of spatial perception is significant to soundscape. However, previous studies on the auditory spatial perception of the soundscape environment have been limited. Based on 21 native binaural-recorded soundscape samples and a set of auditory experiments for subjective spatial perception (SSP), a study of the analysis among semantic parameters, the inter-aural-cross-correlation coefficient (IACC), A-weighted-equal sound-pressure-level (L(eq)), dynamic (D), and SSP is introduced to verify the independent effect of each parameter and to re-determine some of their possible relationships. The results show that the more noisiness the audience perceived, the worse spatial awareness they received, while the closer and more directional the sound source image variations, dynamics, and numbers of sound sources in the soundscape are, the better the spatial awareness would be. Thus, the sensations of roughness, sound intensity, transient dynamic, and the values of Leq and IACC have a suitable range for better spatial perception. A better spatial awareness seems to promote the preference slightly for the audience. Finally, setting SSPs as functions of the semantic parameters and Leq-D-IACC, two linear multivariate evaluation models of subjective spatial perception are proposed.
Analysis of in-flight acoustic data for a twin-engined turboprop airplane
NASA Technical Reports Server (NTRS)
Wilby, J. F.; Wilby, E. G.
1988-01-01
Acoustic measurements were made on the exterior and interior of a general aviation turboprop airplane during four flight tests. The test conditions were carefully controlled and repeated for each flight in order to determine data variability. For the first three flights the cabin was untreated and for the fourth flight the fuselage was treated with glass fiber batts. On the exterior, measured propeller harmonic sound pressure levels showed typical standard deviations of +1.4 dB, -2.3 dB, and turbulent boundary layer pressure levels, +1.2 dB, -1.6. Propeller harmonic levels in the cabin showed greater variability, with typical standard deviations of +2.0 dB, -4.2 dB. When interior sound pressure levels from different flights with different cabin treatments were used to evaluate insertion loss, the standard deviations were typically plus or minus 6.5 dB. This is due in part to the variability of the sound pressure level measurements, but probably is also influenced by changes in the model characteristics of the cabin. Recommendations are made for the planning and performance of future flight tests to measure interior noise of propeller-driven aircraft, either high-speed advanced turboprop or general aviation propellers.
NASA Technical Reports Server (NTRS)
Atwal, Mahabir S.; Heitman, Karen E.; Crocker, Malcolm J.
1986-01-01
The validity of the room equation of Crocker and Price (1982) for predicting the cabin interior sound pressure level was experimentally tested using a specially constructed setup for simultaneous measurements of transmitted sound intensity and interior sound pressure levels. Using measured values of the reverberation time and transmitted intensities, the equation was used to predict the space-averaged interior sound pressure level for three different fuselage conditions. The general agreement between the room equation and experimental test data is considered good enough for this equation to be used for preliminary design studies.
49 CFR 325.37 - Location and operation of sound level measurement system; highway operations.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 5 2011-10-01 2011-10-01 false Location and operation of sound level measurement...; Highway Operations § 325.37 Location and operation of sound level measurement system; highway operations. (a) The microphone of a sound level measurement system that conforms to the rules in § 325.23 of this...
49 CFR 325.71 - Scope of the rules in this subpart.
Code of Federal Regulations, 2010 CFR
2010-10-01
... the sound level generated by a motor vehicle, as displayed on a sound level measurement system, during the measurement of the motor vehicle's sound level emissions at a test site which is not a standard site. (b) The purpose of adding or subtracting a correction factor is to equate the sound level reading...
49 CFR 325.71 - Scope of the rules in this subpart.
Code of Federal Regulations, 2011 CFR
2011-10-01
... the sound level generated by a motor vehicle, as displayed on a sound level measurement system, during the measurement of the motor vehicle's sound level emissions at a test site which is not a standard site. (b) The purpose of adding or subtracting a correction factor is to equate the sound level reading...
24 CFR Appendix I to Subpart B of... - Definition of Acoustical Quantities
Code of Federal Regulations, 2011 CFR
2011-04-01
... National Standard Specification for Type 1 Sound Level Meters S1.4-1971. Fast time-averaging and A...), somewhat as is the ear. With fast time averaging the sound level meter responds particularly to recent... (iii) The maximum sound level obtained with fast averaging time of a sound level meter exceeds the...
24 CFR Appendix I to Subpart B of... - Definition of Acoustical Quantities
Code of Federal Regulations, 2014 CFR
2014-04-01
... National Standard Specification for Type 1 Sound Level Meters S1.4-1971. Fast time-averaging and A...), somewhat as is the ear. With fast time averaging the sound level meter responds particularly to recent... (iii) The maximum sound level obtained with fast averaging time of a sound level meter exceeds the...
24 CFR Appendix I to Subpart B of... - Definition of Acoustical Quantities
Code of Federal Regulations, 2012 CFR
2012-04-01
... National Standard Specification for Type 1 Sound Level Meters S1.4-1971. Fast time-averaging and A...), somewhat as is the ear. With fast time averaging the sound level meter responds particularly to recent... (iii) The maximum sound level obtained with fast averaging time of a sound level meter exceeds the...
24 CFR Appendix I to Subpart B of... - Definition of Acoustical Quantities
Code of Federal Regulations, 2013 CFR
2013-04-01
... National Standard Specification for Type 1 Sound Level Meters S1.4-1971. Fast time-averaging and A...), somewhat as is the ear. With fast time averaging the sound level meter responds particularly to recent... (iii) The maximum sound level obtained with fast averaging time of a sound level meter exceeds the...
Reverberance of AN Existing Hall in Relation to both Subsequent Reverberation Time and Spl
NASA Astrophysics Data System (ADS)
HASE, S.; TAKATSU, A.; SATO, S.; SAKAI, H.; ANDO, Y.
2000-04-01
The reverberance of sound fields was evaluated by psychological tests in a multi-purpose hall with 400 seats. Both the subsequent reverberation time (Tsub) and sound pressure level (SPL) were changed, and the scale values of reverberance for both the music and speech signals were obtained by using the paired comparison method. This study found that Tsuband SPL have an independent influence on the scale value of reverberance. The reverberance increases when both Tsuband SPL are increased.
The behavioural response of Australian fur seals to motor boat noise.
Tripovich, Joy S; Hall-Aspland, Sophie; Charrier, Isabelle; Arnould, John P Y
2012-01-01
Australian fur seals breed on thirteen islands located in the Bass Strait, Australia. Land access to these islands is restricted, minimising human presence but boat access is still permissible with limitations on approach distances. Thirty-two controlled noise exposure experiments were conducted on breeding Australian fur seals to determine their behavioural response to controlled in-air motor boat noise on Kanowna Island (39°10'S, 146°18'E). Our results show there were significant differences in the seals' behaviour at low (64-70 dB) versus high (75-85 dB) sound levels, with seals orientating themselves towards or physically moving away from the louder boat noise at three different sound levels. Furthermore, seals responded more aggressively with one another and were more alert when they heard louder boat noise. Australian fur seals demonstrated plasticity in their vocal responses to boat noise with calls being significantly different between the various sound intensities and barks tending to get faster as the boat noise got louder. These results suggest that Australian fur seals on Kanowna Island show behavioural disturbance to high level boat noise. Consequently, it is recommended that an appropriate level of received boat sound emissions at breeding fur seal colonies be below 74 dB and that these findings be taken into account when evaluating appropriate approach distances and speed limits for boats.
The Behavioural Response of Australian Fur Seals to Motor Boat Noise
Tripovich, Joy S.; Hall-Aspland, Sophie; Charrier, Isabelle; Arnould, John P. Y.
2012-01-01
Australian fur seals breed on thirteen islands located in the Bass Strait, Australia. Land access to these islands is restricted, minimising human presence but boat access is still permissible with limitations on approach distances. Thirty-two controlled noise exposure experiments were conducted on breeding Australian fur seals to determine their behavioural response to controlled in-air motor boat noise on Kanowna Island (39°10′S, 146°18′E). Our results show there were significant differences in the seals' behaviour at low (64–70 dB) versus high (75–85 dB) sound levels, with seals orientating themselves towards or physically moving away from the louder boat noise at three different sound levels. Furthermore, seals responded more aggressively with one another and were more alert when they heard louder boat noise. Australian fur seals demonstrated plasticity in their vocal responses to boat noise with calls being significantly different between the various sound intensities and barks tending to get faster as the boat noise got louder. These results suggest that Australian fur seals on Kanowna Island show behavioural disturbance to high level boat noise. Consequently, it is recommended that an appropriate level of received boat sound emissions at breeding fur seal colonies be below 74 dB and that these findings be taken into account when evaluating appropriate approach distances and speed limits for boats. PMID:22623998
Improvement of impact noise in a passenger car utilizing sound metric based on wavelet transform
NASA Astrophysics Data System (ADS)
Lee, Sang-Kwon; Kim, Ho-Wuk; Na, Eun-Woo
2010-08-01
A new sound metric for impact sound is developed based on the continuous wavelet transform (CWT), a useful tool for the analysis of non-stationary signals such as impact noise. Together with new metric, two other conventional sound metrics related to sound modulation and fluctuation are also considered. In all, three sound metrics are employed to develop impact sound quality indexes for several specific impact courses on the road. Impact sounds are evaluated subjectively by 25 jurors. The indexes are verified by comparing the correlation between the index output and results of a subjective evaluation based on a jury test. These indexes are successfully applied to an objective evaluation for improvement of the impact sound quality for cases where some parts of the suspension system of the test car are modified.
Verbal auditory agnosia in a patient with traumatic brain injury: A case report.
Kim, Jong Min; Woo, Seung Beom; Lee, Zeeihn; Heo, Sung Jae; Park, Donghwi
2018-03-01
Verbal auditory agnosia is the selective inability to recognize verbal sounds. Patients with this disorder lose the ability to understand language, write from dictation, and repeat words with reserved ability to identify nonverbal sounds. However, to the best of our knowledge, there was no report about verbal auditory agnosia in adult patient with traumatic brain injury. He was able to clearly distinguish between language and nonverbal sounds, and he did not have any difficulty in identifying the environmental sounds. However, he did not follow oral commands and could not repeat and dictate words. On the other hand, he had fluent and comprehensible speech, and was able to read and understand written words and sentences. Verbal auditory agnosia INTERVENTION:: He received speech therapy and cognitive rehabilitation during his hospitalization, and he practiced understanding of verbal language by providing written sentences together. Two months after hospitalization, he regained his ability to understand some verbal words. Six months after hospitalization, his ability to understand verbal language was improved to an understandable level when speaking slowly in front of his eyes, but his comprehension of verbal sound language was still word level, not sentence level. This case gives us the lesson that the evaluation of auditory functions as well as cognition and language functions important for accurate diagnosis and appropriate treatment, because the verbal auditory agnosia tends to be easily misdiagnosed as hearing impairment, cognitive dysfunction and sensory aphasia.
Algorithm Development for a Real-Time Military Noise Monitor
2006-03-24
Duration ESLM Enhanced Sound Level Meter ERDC-CERL Engineer Research and Development Center/Construction Engineering Research Laboratory FFT...Fast Fourier Transform FTIG Fort Indiantown Gap Kurt Kurtosis LD Larson Davis Leq Equivalent Sound Level L8eq 8-hr Equivalent...Sound Level Lpk Peak Sound Level m Spectral Slope MCBCL Marine Corps Base Camp Lejeune Neg Number of negative samples NI National
49 CFR 325.57 - Location and operation of sound level measurement systems; stationary test.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 5 2012-10-01 2012-10-01 false Location and operation of sound level measurement...; Stationary Test § 325.57 Location and operation of sound level measurement systems; stationary test. (a) The microphone of a sound level measurement system that conforms to the rules in § 325.23 shall be located at a...
49 CFR 325.57 - Location and operation of sound level measurement systems; stationary test.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 5 2013-10-01 2013-10-01 false Location and operation of sound level measurement...; Stationary Test § 325.57 Location and operation of sound level measurement systems; stationary test. (a) The microphone of a sound level measurement system that conforms to the rules in § 325.23 shall be located at a...
49 CFR 325.23 - Type of measurement systems which may be used.
Code of Federal Regulations, 2011 CFR
2011-10-01
... may be used. The sound level measurement system must meet or exceed the requirements of American National Standard Specification for Sound Level Meters (ANSI S1.4-1971), approved April 27, 1971, issued by..., New York, New York, 10018. (a) A Type 1 sound level meter; (b) A Type 2 sound level meter; or (c) A...
49 CFR 325.57 - Location and operation of sound level measurement systems; stationary test.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 5 2011-10-01 2011-10-01 false Location and operation of sound level measurement...; Stationary Test § 325.57 Location and operation of sound level measurement systems; stationary test. (a) The microphone of a sound level measurement system that conforms to the rules in § 325.23 shall be located at a...
Application of a finite-element model to low-frequency sound insulation in dwellings.
Maluski, S P; Gibbs, B M
2000-10-01
The sound transmission between adjacent rooms has been modeled using a finite-element method. Predicted sound-level difference gave good agreement with experimental data using a full-scale and a quarter-scale model. Results show that the sound insulation characteristics of a party wall at low frequencies strongly depend on the modal characteristics of the sound field of both rooms and of the partition. The effect of three edge conditions of the separating wall on the sound-level difference at low frequencies was examined: simply supported, clamped, and a combination of clamped and simply supported. It is demonstrated that a clamped partition provides greater sound-level difference at low frequencies than a simply supported. It also is confirmed that the sound-pressure level difference is lower in equal room than in unequal room configurations.
Gover, Bradford N; Ryan, James G; Stinson, Michael R
2002-11-01
A measurement system has been developed that is capable of analyzing the directional and spatial variations in a reverberant sound field. A spherical, 32-element array of microphones is used to generate a narrow beam that is steered in 60 directions. Using an omnidirectional loudspeaker as excitation, the sound pressure arriving from each steering direction is measured as a function of time, in the form of pressure impulse responses. By subsequent analysis of these responses, the variation of arriving energy with direction is studied. The directional diffusion and directivity index of the arriving sound can be computed, as can the energy decay rate in each direction. An analysis of the 32 microphone responses themselves allows computation of the point-to-point variation of reverberation time and of sound pressure level, as well as the spatial cross-correlation coefficient, over the extent of the array. The system has been validated in simple sound fields in an anechoic chamber and in a reverberation chamber. The system characterizes these sound fields as expected, both quantitatively from the measures and qualitatively from plots of the arriving energy versus direction. It is anticipated that the system will be of value in evaluating the directional distribution of arriving energy and the degree and diffuseness of sound fields in rooms.
Santarelli, Rosamaria; Magnavita, Vincenzo; De Filippi, Roberta; Ventura, Laura; Genovese, Elisabetta; Arslan, Edoardo
2009-04-01
To compare speech perception performance in children fitted with previous generation Nucleus sound processor, Sprint or Esprit 3G, and the Freedom, the most recently released system from the Cochlear Corporation that features a larger input dynamic range. Prospective intrasubject comparative study. University Medical Center. Seventeen prelingually deafened children who had received the Nucleus 24 cochlear implant and used the Sprint or Esprit 3G sound processor. Cochlear implantation with Cochlear device. Speech perception was evaluated at baseline (Sprint, n = 11; Esprit 3G, n = 6) and after 1 month's experience with the Freedom sound processor. Identification and recognition of disyllabic words and identification of vowels were performed via recorded voice in quiet (70 dB [A]), in the presence of background noise at various levels of signal-to-noise ratio (+10, +5, 0, -5) and at a soft presentation level (60 dB [A]). Consonant identification and recognition of disyllabic words, trisyllabic words, and sentences were evaluated in live voice. Frequency discrimination was measured in a subset of subjects (n = 5) by using an adaptive, 3-interval, 3-alternative, forced-choice procedure. Identification of disyllabic words administered at a soft presentation level showed a significant increase when switching to the Freedom compared with the previously worn processor in children using the Sprint or Esprit 3G. Identification and recognition of disyllabic words in the presence of background noise as well as consonant identification and sentence recognition increased significantly for the Freedom compared with the previously worn device only in children fitted with the Sprint. Frequency discrimination was significantly better when switching to the Freedom compared with the previously worn processor. Serial comparisons revealed that that speech perception performance evaluated in children aged 5 to 15 years was superior with the Freedom than previous generations of Nucleus sound processors. These differences are deemed to ensue from an increased input dynamic range, a feature that offers potentially enhanced phonemic discrimination.
Kastelein, Ronald A; van Heerden, Dorianne; Gransier, Robin; Hoek, Lean
2013-12-01
The high under-water sound pressure levels (SPLs) produced during pile driving to build offshore wind turbines may affect harbor porpoises. To estimate the discomfort threshold of pile driving sounds, a porpoise in a quiet pool was exposed to playbacks (46 strikes/min) at five SPLs (6 dB steps: 130-154 dB re 1 μPa). The spectrum of the impulsive sound resembled the spectrum of pile driving sound at tens of kilometers from the pile driving location in shallow water such as that found in the North Sea. The animal's behavior during test and baseline periods was compared. At and above a received broadband SPL of 136 dB re 1 μPa [zero-peak sound pressure level: 151 dB re 1 μPa; t90: 126 ms; sound exposure level of a single strike (SELss): 127 dB re 1 μPa(2) s] the porpoise's respiration rate increased in response to the pile driving sounds. At higher levels, he also jumped out of the water more often. Wild porpoises are expected to move tens of kilometers away from offshore pile driving locations; response distances will vary with context, the sounds' source level, parameters influencing sound propagation, and background noise levels. Copyright © 2013 Elsevier Ltd. All rights reserved.
Knauert, Melissa; Jeon, Sangchoon; Murphy, Terrence E.; Yaggi, H. Klar; Pisani, Margaret A.; Redeker, Nancy S.
2016-01-01
Purpose Sound levels in the intensive care unit (ICU) are universally elevated and are believed to contribute to sleep and circadian disruption. The purpose of this study is to compare overnight ICU sound levels and peak occurrence on A- versus C-weighted scales. Materials and Methods This was a prospective observational study of overnight sound levels in 59 medical ICU patient rooms. Sound level was recorded every 10 seconds on A- and C-weighted decibel scales. Equivalent sound level (Leq) and sound peaks were reported for full and partial night periods. Results The overnight A-weighted Leq of 53.6 dBA was well above World Health Organization (WHO) recommendations; overnight C-weighted Leq was 63.1 dBC (no WHO recommendations). Peak sound occurrence ranged from 1.8 to 23.3 times per hour. Illness severity, mechanical ventilation and delirium were not associated with Leq or peak occurrence. Leq and peak measures for A- and C-weighted decibel scales were significantly different from each other. Conclusions Sound levels in the medical ICU are high throughout the night. Patient factors were not associated with Leq or peak occurrence. Significant discordance between A- and C-weighted values suggests that low frequency sound is a meaningful factor in the medical ICU environment. PMID:27546739
Survey of Occupational Noise Exposure in CF Personnel in Selected High-Risk Trades
2003-11-01
peak, maximum level , minimum level , average sound level , time weighted average, dose, projected 8-hour dose, and upper limit time were measured for...10 4.4.2 Maximum Sound Level ...11 4.4.3 Minimum Sound Level
Characterizing urban areas with good sound quality: development of a research protocol.
van Kempen, Elise; Devilee, Jeroen; Swart, Wim; van Kamp, Irene
2014-01-01
Due to rapid urbanization, the spatial variation between wanted and unwanted sounds will decrease or even disappear. Consequently, the characteristics of (urban) areas where people can temporarily withdraw themselves from urban stressors such as noise may change or become increasingly scarce. Hardly any research has been carried out into the positive health effects of spending time in areas with a good sound quality. One of the problems is that an overview of what aspects determines good sound quality in urban areas and how these are interrelated is lacking. This paper reviews the literature pertaining to the sound quality of urban areas. Aim is to summarize what is known about the influence of social, spatial, and physical aspects other than sounds, on peoples' perception of urban sound qualities. Literature from both conventional sound research and from the so-called soundscape field, published between 2000 and the beginning of 2013 in English or Dutch, was evaluated. Although a general set of validated indicators that can be directly applied, is not available yet, a set of indicators was derived from the literature. These form the basis of a study protocol that will be applied in "Towards a Sustainable acoustic Environment", a project that aims to describe sound qualities at a low-scale level. Key-elements of this study protocol, including a questionnaire and the systematic audit of neighborhoods, were presented in this paper.
Noise in neonatal intensive care units (NICUs) and its effect on high risk newborns
NASA Astrophysics Data System (ADS)
Lasky, Robert E.; Williams, Amber L.; van Drongelen, Wim; Gray, Lincoln C.
2005-09-01
We conducted sound surveys in a large state of the art NICU with six separate rooms devoted to the sickest babies requiring the most intensive care (Level III) and six rooms devoted to babies requiring special but less intensive care (Level II). Each room was capable of caring for up to 8 babies. Additionally, there were 8 individual Isolation rooms. We used Larson Davis Spark squflg 703+ dosimeters to record 21 week long sound surveys, seven in each type of room. The American Academy of Pediatrics (1997) has recommended that sound levels in NICUs should never exceed 45 dB(A). That recommendation was exceeded 73.6% of the time in Level II, 92.1% of the time in Isolation, and 96.6% of the time in Level III. Sound levels were lowest in the Level II rooms especially for the softest sounds recorded (L90 and L70). Level III rooms were noisiest except for the noisiest decile of sound (L10). Isolation rooms were noisiest at the highest sound levels (probably because of their reverberant construction materials and enclosed space). Autocorrelation functions were calculated identifying periodic components in all three rooms at about 12 and 24 hrs. Periodic variations were very small compared to random sound variations.
NASA Astrophysics Data System (ADS)
KAWAI, K.; YANO, T.
2002-02-01
This paper reports an experimental study determining the effects of the type and loudness of individual sounds on the overall impression of the sound environment. Field and laboratory experiments were carried out. In each experiment, subjects evaluated the sound environment presented, which consisted of combinations of three individual sounds of road traffic, singing crickets and the murmuring of a river, with five bipolar adjective scales such as Good-Bad, Active-Calm and Natural-Artificial. Overall loudness had the strongest effect on most types of evaluations; relative SPL has a greater effect than overall loudness on a particular evaluation of the natural-artificial scale. The test sounds in the field experiment were generally evaluated as more good and more natural than those in the laboratory. The results of comparisons between laboratory and field sounds indicate a difference in the trend between them. This difference may be explained by the term of selective listening but that needs further investigation.
Common sole larvae survive high levels of pile-driving sound in controlled exposure experiments.
Bolle, Loes J; de Jong, Christ A F; Bierman, Stijn M; van Beek, Pieter J G; van Keeken, Olvin A; Wessels, Peter W; van Damme, Cindy J G; Winter, Hendrik V; de Haan, Dick; Dekeling, René P A
2012-01-01
In view of the rapid extension of offshore wind farms, there is an urgent need to improve our knowledge on possible adverse effects of underwater sound generated by pile-driving. Mortality and injuries have been observed in fish exposed to loud impulse sounds, but knowledge on the sound levels at which (sub-)lethal effects occur is limited for juvenile and adult fish, and virtually non-existent for fish eggs and larvae. A device was developed in which fish larvae can be exposed to underwater sound. It consists of a rigid-walled cylindrical chamber driven by an electro-dynamical sound projector. Samples of up to 100 larvae can be exposed simultaneously to a homogeneously distributed sound pressure and particle velocity field. Recorded pile-driving sounds could be reproduced accurately in the frequency range between 50 and 1000 Hz, at zero to peak pressure levels up to 210 dB re 1µPa(2) (zero to peak pressures up to 32 kPa) and single pulse sound exposure levels up to 186 dB re 1µPa(2)s. The device was used to examine lethal effects of sound exposure in common sole (Solea solea) larvae. Different developmental stages were exposed to various levels and durations of pile-driving sound. The highest cumulative sound exposure level applied was 206 dB re 1µPa(2)s, which corresponds to 100 strikes at a distance of 100 m from a typical North Sea pile-driving site. The results showed no statistically significant differences in mortality between exposure and control groups at sound exposure levels which were well above the US interim criteria for non-auditory tissue damage in fish. Although our findings cannot be extrapolated to fish larvae in general, as interspecific differences in vulnerability to sound exposure may occur, they do indicate that previous assumptions and criteria may need to be revised.
Common Sole Larvae Survive High Levels of Pile-Driving Sound in Controlled Exposure Experiments
Bolle, Loes J.; de Jong, Christ A. F.; Bierman, Stijn M.; van Beek, Pieter J. G.; van Keeken, Olvin A.; Wessels, Peter W.; van Damme, Cindy J. G.; Winter, Hendrik V.; de Haan, Dick; Dekeling, René P. A.
2012-01-01
In view of the rapid extension of offshore wind farms, there is an urgent need to improve our knowledge on possible adverse effects of underwater sound generated by pile-driving. Mortality and injuries have been observed in fish exposed to loud impulse sounds, but knowledge on the sound levels at which (sub-)lethal effects occur is limited for juvenile and adult fish, and virtually non-existent for fish eggs and larvae. A device was developed in which fish larvae can be exposed to underwater sound. It consists of a rigid-walled cylindrical chamber driven by an electro-dynamical sound projector. Samples of up to 100 larvae can be exposed simultaneously to a homogeneously distributed sound pressure and particle velocity field. Recorded pile-driving sounds could be reproduced accurately in the frequency range between 50 and 1000 Hz, at zero to peak pressure levels up to 210 dB re 1µPa2 (zero to peak pressures up to 32 kPa) and single pulse sound exposure levels up to 186 dB re 1µPa2s. The device was used to examine lethal effects of sound exposure in common sole (Solea solea) larvae. Different developmental stages were exposed to various levels and durations of pile-driving sound. The highest cumulative sound exposure level applied was 206 dB re 1µPa2s, which corresponds to 100 strikes at a distance of 100 m from a typical North Sea pile-driving site. The results showed no statistically significant differences in mortality between exposure and control groups at sound exposure levels which were well above the US interim criteria for non-auditory tissue damage in fish. Although our findings cannot be extrapolated to fish larvae in general, as interspecific differences in vulnerability to sound exposure may occur, they do indicate that previous assumptions and criteria may need to be revised. PMID:22431996
Brunner, Monika; Stellzig-Eisenhauer, Angelika; Pröschel, Ute; Verres, Rolf; Komposch, Gerda
2005-11-01
To evaluate the immediate, long-term, and carry-over effects of nasopharyngoscopic biofeedback therapy in patients with cleft palate who exhibit velopharyngeal dysfunction (VPD). Pre- versus posttreatment and follow-up comparisons. Cleft palate center of the Heidelberg University Hospital, Heidelberg, Germany. Eleven patients with VPD who had received conventional speech therapy without showing significant improvement. A four-stage feedback procedure. The patients watched and evaluated their velopharyngeal (VP) valving during speech by an endoscopic image displayed on a video monitor. Two feedback sessions took place for every target sound. Mean occurrence of VP closure during speech sound production on different linguistic levels. Patients' self-perception was assessed by a questionnaire and speech diary. Significant improvement and stability of VP closure was noted. Mean occurrence of VP closure was 5% before therapy, 91% after two biofeedback sessions, and 86% in the follow-up after 6 months. Velopharyngeal dysfunction associated with compensatory articulation proved to be equally well trained as VPD on sounds with good articulatory placement. No significant difference was observed in the degree of improvement between phoneme-specific VPD and generalized VPD. The transfer to the level of words and sentences was successful and showed significant stability. The stability of VP closure for vowels was less than the stability for fricatives and stop sounds. Patients gained improved auditory and kinesthetic self-perception of their articulation. Nasopharyngoscopic biofeedback therapy proves to be a quick and effective method to change VPD. It shows stable results and carry-over effects.
NASA Astrophysics Data System (ADS)
Ipatov, M. S.; Ostroumov, M. N.; Sobolev, A. F.
2012-07-01
Experimental results are presented on the effect of both the sound pressure level and the type of spectrum of a sound source on the impedance of an acoustic lining. The spectra under study include those of white noise, a narrow-band signal, and a signal with a preset waveform. It is found that, to obtain reliable data on the impedance of an acoustic lining from the results of interferometric measurements, the total sound pressure level of white noise or the maximal sound pressure level of a pure tone (at every oscillation frequency) needs to be identical to the total sound pressure level of the actual source at the site of acoustic lining on the channel wall.
24 CFR 51.103 - Criteria and standards.
Code of Federal Regulations, 2010 CFR
2010-04-01
... decibels to sound levels in the night from 10 p.m. to 7 a.m. Mathematical expressions for average sound..., as indicated in § 51.106(a)(3). Methods for assessing the contribution of loud impulsive sounds to day-night average sound level at a site and mathematical expressions for determining whether a sound...
NASA Astrophysics Data System (ADS)
Kauahikaua, J.
A controlled source, time domain electromagnetic (TDEM) sounding survey was conducted in the Calico Hills area of the Nevada Test Site (NTS). The geoelectric structure was determined as an aid in the evaluation of the site for possible future storage of spent nuclear fuel or high level nuclear waste. The data were initially interpreted with a simple scheme that produces an apparent resistivity versus depth curve from the vertical magnetic field data. These curves are qualitatively interpreted much like standard Schlumberger resistivity sounding curves. Final interpretation made use of a layered earth Marquardt inversion computer program. The results combined with those from a set of Schlumberger soundings in the area show that there is a moderately resistive basement at a depth no greater than 800 meters. The basement resistivity is greater than 100 ohm meters.
Urban noise functional stratification for estimating average annual sound level.
Rey Gozalo, Guillermo; Barrigón Morillas, Juan Miguel; Prieto Gajardo, Carlos
2015-06-01
Road traffic noise causes many health problems and the deterioration of the quality of urban life; thus, adequate spatial noise and temporal assessment methods are required. Different methods have been proposed for the spatial evaluation of noise in cities, including the categorization method. Until now, this method has only been applied for the study of spatial variability with measurements taken over a week. In this work, continuous measurements of 1 year carried out in 21 different locations in Madrid (Spain), which has more than three million inhabitants, were analyzed. The annual average sound levels and the temporal variability were studied in the proposed categories. The results show that the three proposed categories highlight the spatial noise stratification of the studied city in each period of the day (day, evening, and night) and in the overall indicators (L(And), L(Aden), and L(A24)). Also, significant differences between the diurnal and nocturnal sound levels show functional stratification in these categories. Therefore, this functional stratification offers advantages from both spatial and temporal perspectives by reducing the sampling points and the measurement time.
Bertucci, Frédéric; Parmentier, Eric; Lecellier, Gaël; Hawkins, Anthony D.; Lecchini, David
2016-01-01
Different marine habitats are characterised by different soundscapes. How or which differences may be representative of the habitat characteristics and/or community structure remains however to be explored. A growing project in passive acoustics is to find a way to use soundscapes to have information on the habitat and on its changes. In this study we have successfully tested the potential of two acoustic indices, i.e. the average sound pressure level and the acoustic complexity index based on the frequency spectrum. Inside and outside marine protected areas of Moorea Island (French Polynesia), sound pressure level was positively correlated with the characteristics of the substratum and acoustic complexity was positively correlated with fish diversity. It clearly shows soundscape can be used to evaluate the acoustic features of marine protected areas, which presented a significantly higher ambient sound pressure level and were more acoustically complex than non-protected areas. This study further emphasizes the importance of acoustics as a tool in the monitoring of marine environments and in the elaboration and management of future conservation plans. PMID:27629650
Bertucci, Frédéric; Parmentier, Eric; Lecellier, Gaël; Hawkins, Anthony D; Lecchini, David
2016-09-15
Different marine habitats are characterised by different soundscapes. How or which differences may be representative of the habitat characteristics and/or community structure remains however to be explored. A growing project in passive acoustics is to find a way to use soundscapes to have information on the habitat and on its changes. In this study we have successfully tested the potential of two acoustic indices, i.e. the average sound pressure level and the acoustic complexity index based on the frequency spectrum. Inside and outside marine protected areas of Moorea Island (French Polynesia), sound pressure level was positively correlated with the characteristics of the substratum and acoustic complexity was positively correlated with fish diversity. It clearly shows soundscape can be used to evaluate the acoustic features of marine protected areas, which presented a significantly higher ambient sound pressure level and were more acoustically complex than non-protected areas. This study further emphasizes the importance of acoustics as a tool in the monitoring of marine environments and in the elaboration and management of future conservation plans.
Encoding of sound envelope transients in the auditory cortex of juvenile rats and adult rats.
Lu, Qi; Jiang, Cuiping; Zhang, Jiping
2016-02-01
Accurate neural processing of time-varying sound amplitude and spectral information is vital for species-specific communication. During postnatal development, cortical processing of sound frequency undergoes progressive refinement; however, it is not clear whether cortical processing of sound envelope transients also undergoes age-related changes. We determined the dependence of neural response strength and first-spike latency on sound rise-fall time across sound levels in the primary auditory cortex (A1) of juvenile (P20-P30) rats and adult (8-10 weeks) rats. A1 neurons were categorized as "all-pass", "short-pass", or "mixed" ("all-pass" at high sound levels to "short-pass" at lower sound levels) based on the normalized response strength vs. rise-fall time functions across sound levels. The proportions of A1 neurons within each of the three categories in juvenile rats were similar to that in adult rats. In general, with increasing rise-fall time, the average response strength decreased and the average first-spike latency increased in A1 neurons of both groups. At a given sound level and rise-fall time, the average normalized neural response strength did not differ significantly between the two age groups. However, the A1 neurons in juvenile rats showed greater absolute response strength, longer first-spike latency compared to those in adult rats. In addition, at a constant sound level, the average first-spike latency of juvenile A1 neurons was more sensitive to changes in rise-fall time. Our results demonstrate the dependence of the responses of rat A1 neurons on sound rise-fall time, and suggest that the response latency exhibit some age-related changes in cortical representation of sound envelope rise time. Copyright © 2015 Elsevier Ltd. All rights reserved.
The influence of neonatal intensive care unit design on sound level.
Chen, Hsin-Li; Chen, Chao-Huei; Wu, Chih-Chao; Huang, Hsiu-Jung; Wang, Teh-Ming; Hsu, Chia-Chi
2009-12-01
Excessive noise in nurseries has been found to cause adverse effects in infants, especially preterm infants in neonatal intensive care units (NICUs). The NICU design may influence the background sound level. We compared the sound level in two differently designed spaces in one NICU. We hypothesized that the sound level in an enclosed space would be quieter than in an open space. Sound levels were measured continuously 24 hours a day in two separate spaces at the same time, one enclosed and one open. Sound-level meters were placed near beds in each room. Sound levels were expressed as decibels, A-weighted (dBA) and presented as hourly L(eq), L(max), L(10), and L(90). The hourly L(eq) in the open space (50.8-57.2dB) was greater than that of the enclosed space (45.9-51.7dB), with a difference of 0.4-10.4dB, and a mean difference of 4.5dB (p<0.0001). The hourly L(10), L(90), and L(max) in the open space also exceeded that in the enclosed space (p<0.0001). The sound level measured in the enclosed space was quieter than in the open space. The design of bed space should be taken into consideration when building a new NICU. Besides the design of NICU architecture, continuous monitoring of sound level in the NICU is important to maintain a quiet environment.
Harris, Debra D
2015-01-01
Three flooring materials, terrazzo, rubber, and carpet tile, in patient unit corridors were compared for absorption of sound, comfort, light reflectance, employee perceptions and preferences, and patient satisfaction. Environmental stressors, such as noise and ergonomic factors, effect healthcare workers and patients, contributing to increased fatigue, anxiety and stress, decreased productivity, and patient safety and satisfaction. A longitudinal comparative cohort study comparing three types of flooring assessed sound levels, healthcare worker responses, and patient Hospital Consumer Assessment of Healthcare Providers and Systems (HCAHPS) ratings over 42 weeks. A linear mixed model analysis was conducted to determine significant differences between the means for participant responses and objective sound meter data during all three phases of the study. A significant difference was found for sound levels between flooring type for equivalent continuous sound levels. Carpet tile performed better for sound attenuation by absorption, reducing sound levels 3.14 dBA. Preferences for flooring materials changed over the course of the study. The HCAHPS ratings aligned with the sound meter data showing that patients perceived the noise levels to be lower with carpet tiles, improving patient satisfaction ratings. Perceptions for healthcare staff and patients were aligned with the sound meter data. Carpet tile provides sound absorption that affects sound levels and influences occupant's perceptions of environmental factors that contribute to the quality of the indoor environment. Flooring that provides comfort underfoot, easy cleanability, and sound absorption influence healthcare worker job satisfaction and patient satisfaction with their patient experience. © The Author(s) 2015.
Garinis, Angela C; Liao, Selena; Cross, Campbell P; Galati, Johnathan; Middaugh, Jessica L; Mace, Jess C; Wood, Anna-Marie; McEvoy, Lindsey; Moneta, Lauren; Lubianski, Troy; Coopersmith, Noe; Vigo, Nicholas; Hart, Christopher; Riddle, Artur; Ettinger, Olivia; Nold, Casey; Durham, Heather; MacArthur, Carol; McEvoy, Cynthia; Steyger, Peter S
2017-06-01
Hearing loss rates in infants admitted to neonatal intensive care units (NICU) run at 2-15%, compared to 0.3% in full-term births. The etiology of this difference remains poorly understood. We examined whether the level of ambient sound and/or cumulative gentamicin (an aminoglycoside) exposure affect NICU hearing screening results, as either exposure can cause acquired, permanent hearing loss. We hypothesized that higher levels of ambient sound in the NICU, and/or gentamicin dosing, increase the risk of referral on the distortion product otoacoustic emission (DPOAE) assessments and/or automated auditory brainstem response (AABR) screens. This was a prospective pilot outcomes study of 82 infants (<37 weeks gestational age) admitted to the NICU at Oregon Health & Science University. An ER-200D sound pressure level dosimeter was used to collect daily sound exposure in the NICU for each neonate. Gentamicin dosing was also calculated for each infant, including the total daily dose based on body mass (mg/kg/day), as well as the total number of treatment days. DPOAE and AABR assessments were conducted prior to discharge to evaluate hearing status. Exclusion criteria included congenital infections associated with hearing loss, and congenital craniofacial or otologic abnormalities. The mean level of ambient sound was 62.9 dBA (range 51.8-70.6 dBA), greatly exceeding American Academy of Pediatrics (AAP) recommendation of <45.0 dBA. More than 80% of subjects received gentamicin treatment. The referral rate for (i) AABRs, (frequency range: ∼1000-4000 Hz), was 5%; (ii) DPOAEs with a broad F2 frequency range (2063-10031 Hz) was 39%; (iii) DPOAEs with a low-frequency F2 range (<4172 Hz) was 29%, and (iv) DPOAEs with a high-frequency F2 range (>4172 Hz) was 44%. DPOAE referrals were significantly greater for infants receiving >2 days of gentamicin dosing compared to fewer doses (p = 0.004). The effect of sound exposure and gentamicin treatment on hearing could not be determined due to the low number of NICU infants without gentamicin exposure (for control comparisons). All infants were exposed to higher levels of ambient sound that substantially exceed AAP guidelines. More referrals were generated by DPOAE assessments than with AABR screens, with significantly more DPOAE referrals with a high-frequency F2 range, consistent with sound- and/or gentamicin-induced cochlear dysfunction. Adding higher frequency DPOAE assessments to existing NICU hearing screening protocols could better identify infants at-risk for ototoxicity. Copyright © 2017 Elsevier B.V. All rights reserved.
Effects of sound level fluctuations on annoyance caused by aircraft-flyover noise
NASA Technical Reports Server (NTRS)
Mccurdy, D. A.
1979-01-01
A laboratory experiment was conducted to determine the effects of variations in the rate and magnitude of sound level fluctuations on the annoyance caused by aircraft-flyover noise. The effects of tonal content, noise duration, and sound pressure level on annoyance were also studied. An aircraft-noise synthesis system was used to synthesize 32 aircraft-flyover noise stimuli representing the factorial combinations of 2 tone conditions, 2 noise durations, 2 sound pressure levels, 2 level fluctuation rates, and 2 level fluctuation magnitudes. Thirty-two test subjects made annoyance judgements on a total of 64 stimuli in a subjective listening test facility simulating an outdoor acoustic environment. Variations in the rate and magnitude of level fluctuations were found to have little, if any, effect on annoyance. Tonal content, noise duration, sound pressure level, and the interaction of tonal content with sound pressure level were found to affect the judged annoyance significantly. The addition of tone corrections and/or duration corrections significantly improved the annoyance prediction ability of noise rating scales.
Decoding sound level in the marmoset primary auditory cortex.
Sun, Wensheng; Marongelli, Ellisha N; Watkins, Paul V; Barbour, Dennis L
2017-10-01
Neurons that respond favorably to a particular sound level have been observed throughout the central auditory system, becoming steadily more common at higher processing areas. One theory about the role of these level-tuned or nonmonotonic neurons is the level-invariant encoding of sounds. To investigate this theory, we simulated various subpopulations of neurons by drawing from real primary auditory cortex (A1) neuron responses and surveyed their performance in forming different sound level representations. Pure nonmonotonic subpopulations did not provide the best level-invariant decoding; instead, mixtures of monotonic and nonmonotonic neurons provided the most accurate decoding. For level-fidelity decoding, the inclusion of nonmonotonic neurons slightly improved or did not change decoding accuracy until they constituted a high proportion. These results indicate that nonmonotonic neurons fill an encoding role complementary to, rather than alternate to, monotonic neurons. NEW & NOTEWORTHY Neurons with nonmonotonic rate-level functions are unique to the central auditory system. These level-tuned neurons have been proposed to account for invariant sound perception across sound levels. Through systematic simulations based on real neuron responses, this study shows that neuron populations perform sound encoding optimally when containing both monotonic and nonmonotonic neurons. The results indicate that instead of working independently, nonmonotonic neurons complement the function of monotonic neurons in different sound-encoding contexts. Copyright © 2017 the American Physiological Society.
NASA Astrophysics Data System (ADS)
Fujii, Ayaka; Wakatsuki, Naoto; Mizutani, Koichi
2016-01-01
A method of suppressing sound radiation to the far field of a near-field acoustic communication system using an evanescent sound field is proposed. The amplitude of the evanescent sound field generated from an infinite vibrating plate attenuates exponentially with increasing a distance from the surface of the vibrating plate. However, a discontinuity of the sound field exists at the edge of the finite vibrating plate in practice, which broadens the wavenumber spectrum. A sound wave radiates over the evanescent sound field because of broadening of the wavenumber spectrum. Therefore, we calculated the optimum distribution of the particle velocity on the vibrating plate to reduce the broadening of the wavenumber spectrum. We focused on a window function that is utilized in the field of signal analysis for reducing the broadening of the frequency spectrum. The optimization calculation is necessary for the design of window function suitable for suppressing sound radiation and securing a spatial area for data communication. In addition, a wide frequency bandwidth is required to increase the data transmission speed. Therefore, we investigated a suitable method for calculating the sound pressure level at the far field to confirm the variation of the distribution of sound pressure level determined on the basis of the window shape and frequency. The distribution of the sound pressure level at a finite distance was in good agreement with that obtained at an infinite far field under the condition generating the evanescent sound field. Consequently, the window function was optimized by the method used to calculate the distribution of the sound pressure level at an infinite far field using the wavenumber spectrum on the vibrating plate. According to the result of comparing the distributions of the sound pressure level in the cases with and without the window function, it was confirmed that the area whose sound pressure level was reduced from the maximum level to -50 dB was extended. Additionally, we designed a sound insulator so as to realize a similar distribution of the particle velocity to that obtained using the optimized window function. Sound radiation was suppressed using a sound insulator put above the vibrating surface in the simulation using the three-dimensional finite element method. On the basis of this finding, it was suggested that near-field acoustic communication which suppressed sound radiation can be realized by applying the optimized window function to the particle velocity field.
Continuous robust sound event classification using time-frequency features and deep learning
Song, Yan; Xiao, Wei; Phan, Huy
2017-01-01
The automatic detection and recognition of sound events by computers is a requirement for a number of emerging sensing and human computer interaction technologies. Recent advances in this field have been achieved by machine learning classifiers working in conjunction with time-frequency feature representations. This combination has achieved excellent accuracy for classification of discrete sounds. The ability to recognise sounds under real-world noisy conditions, called robust sound event classification, is an especially challenging task that has attracted recent research attention. Another aspect of real-word conditions is the classification of continuous, occluded or overlapping sounds, rather than classification of short isolated sound recordings. This paper addresses the classification of noise-corrupted, occluded, overlapped, continuous sound recordings. It first proposes a standard evaluation task for such sounds based upon a common existing method for evaluating isolated sound classification. It then benchmarks several high performing isolated sound classifiers to operate with continuous sound data by incorporating an energy-based event detection front end. Results are reported for each tested system using the new task, to provide the first analysis of their performance for continuous sound event detection. In addition it proposes and evaluates a novel Bayesian-inspired front end for the segmentation and detection of continuous sound recordings prior to classification. PMID:28892478
Continuous robust sound event classification using time-frequency features and deep learning.
McLoughlin, Ian; Zhang, Haomin; Xie, Zhipeng; Song, Yan; Xiao, Wei; Phan, Huy
2017-01-01
The automatic detection and recognition of sound events by computers is a requirement for a number of emerging sensing and human computer interaction technologies. Recent advances in this field have been achieved by machine learning classifiers working in conjunction with time-frequency feature representations. This combination has achieved excellent accuracy for classification of discrete sounds. The ability to recognise sounds under real-world noisy conditions, called robust sound event classification, is an especially challenging task that has attracted recent research attention. Another aspect of real-word conditions is the classification of continuous, occluded or overlapping sounds, rather than classification of short isolated sound recordings. This paper addresses the classification of noise-corrupted, occluded, overlapped, continuous sound recordings. It first proposes a standard evaluation task for such sounds based upon a common existing method for evaluating isolated sound classification. It then benchmarks several high performing isolated sound classifiers to operate with continuous sound data by incorporating an energy-based event detection front end. Results are reported for each tested system using the new task, to provide the first analysis of their performance for continuous sound event detection. In addition it proposes and evaluates a novel Bayesian-inspired front end for the segmentation and detection of continuous sound recordings prior to classification.
33 CFR 86.07 - Directional properties.
Code of Federal Regulations, 2011 CFR
2011-07-01
... properties. The sound pressure level of a directional whistle shall be not more than 4 dB below the sound... forward axis. The sound pressure level of the whistle in any other direction in the horizontal plane shall not be more than 10 dB less than the sound pressure level specified for the forward axis, so that the...
NASA Technical Reports Server (NTRS)
Groza, A.; Calciu, J.; Nicola, I.; Ionasek, A.
1974-01-01
Sound level measurements on noise sources on buses are used to observe the effects of attenuating acoustic pressure levels inside the bus by sound-proofing during complete repair. A spectral analysis of the sound level as a function of motor speed, bus speed along the road, and the category of the road is reported.
The sound intensity and characteristics of variable-pitch pulse oximeters.
Yamanaka, Hiroo; Haruna, Junichi; Mashimo, Takashi; Akita, Takeshi; Kinouchi, Keiko
2008-06-01
Various studies worldwide have found that sound levels in hospitals significantly exceed the World Health Organization (WHO) guidelines, and that this noise is associated with audible signals from various medical devices. The pulse oximeter is now widely used in health care; however the health effects associated with the noise from this equipment remain largely unclarified. Here, we analyzed the sounds of variable-pitch pulse oximeters, and discussed the possible associated risk of sleep disturbance, annoyance, and hearing loss. The Nellcor N 595 and Masimo SET Radical pulse oximeters were measured for equivalent continuous A-weighted sound pressure levels (L(Aeq)), loudness levels, and loudness. Pulse beep pitches were also identified using Fast Fourier Transform (FFT) analysis and compared with musical pitches as controls. Almost all alarm sounds and pulse beeps from the instruments tested exceeded 30 dBA, a level that may induce sleep disturbance and annoyance. Several alarm sounds emitted by the pulse oximeters exceeded 70 dBA, which is known to induce hearing loss. The loudness of the alarm sound of each pulse oximeter did not change in proportion to the sound volume level. The pitch of each pulse beep did not correspond to musical pitch levels. The results indicate that sounds from pulse oximeters pose a potential risk of not only sleep disturbance and annoyance but also hearing loss, and that these sounds are unnatural for human auditory perception.
The effect of spatial distribution on the annoyance caused by simultaneous sounds
NASA Astrophysics Data System (ADS)
Vos, Joos; Bronkhorst, Adelbert W.; Fedtke, Thomas
2004-05-01
A considerable part of the population is exposed to simultaneous and/or successive environmental sounds from different sources. In many cases, these sources are different with respect to their locations also. In a laboratory study, it was investigated whether the annoyance caused by the multiple sounds is affected by the spatial distribution of the sources. There were four independent variables: (1) sound category (stationary or moving), (2) sound type (stationary: lawn-mower, leaf-blower, and chain saw; moving: road traffic, railway, and motorbike), (3) spatial location (left, right, and combinations), and (4) A-weighted sound exposure level (ASEL of single sources equal to 50, 60, or 70 dB). In addition to the individual sounds in isolation, various combinations of two or three different sources within each sound category and sound level were presented for rating. The annoyance was mainly determined by sound level and sound source type. In most cases there were neither significant main effects of spatial distribution nor significant interaction effects between spatial distribution and the other variables. It was concluded that for rating the spatially distrib- uted sounds investigated, the noise dose can simply be determined by a summation of the levels for the left and right channels. [Work supported by CEU.
Measor, Kevin; Yarrow, Stuart; Razak, Khaleel A
2018-05-26
Sound level processing is a fundamental function of the auditory system. To determine how the cortex represents sound level, it is important to quantify how changes in level alter the spatiotemporal structure of cortical ensemble activity. This is particularly true for echolocating bats that have control over, and often rapidly adjust, call level to actively change echo level. To understand how cortical activity may change with sound level, here we mapped response rate and latency changes with sound level in the auditory cortex of the pallid bat. The pallid bat uses a 60-30 kHz downward frequency modulated (FM) sweep for echolocation. Neurons tuned to frequencies between 30 and 70 kHz in the auditory cortex are selective for the properties of FM sweeps used in echolocation forming the FM sweep selective region (FMSR). The FMSR is strongly selective for sound level between 30 and 50 dB SPL. Here we mapped the topography of level selectivity in the FMSR using downward FM sweeps and show that neurons with more monotonic rate level functions are located in caudomedial regions of the FMSR overlapping with high frequency (50-60 kHz) neurons. Non-monotonic neurons dominate the FMSR, and are distributed across the entire region, but there is no evidence for amplitopy. We also examined how first spike latency of FMSR neurons change with sound level. The majority of FMSR neurons exhibit paradoxical latency shift wherein the latency increases with sound level. Moreover, neurons with paradoxical latency shifts are more strongly level selective and are tuned to lower sound level than neurons in which latencies decrease with level. These data indicate a clustered arrangement of neurons according to monotonicity, with no strong evidence for finer scale topography, in the FMSR. The latency analysis suggests mechanisms for strong level selectivity that is based on relative timing of excitatory and inhibitory inputs. Taken together, these data suggest how the spatiotemporal spread of cortical activity may represent sound level. Copyright © 2018. Published by Elsevier B.V.
Acoustical evaluation of preschool classrooms
NASA Astrophysics Data System (ADS)
Yang, Wonyoung; Hodgson, Murray
2003-10-01
An investigation was made of the acoustical environments in the Berwick Preschool, Vancouver, in response to complaints by the teachers. Reverberation times (RT), background noise levels (BNL), and in-class sound levels (Leq) were measured for acoustical evaluation in the classrooms. With respect to the measured RT and BNL, none of the classrooms in the preschool were acceptable according to the criteria relevant to this study. A questionnaire was administered to the teachers to assess their subjective responses to the acoustical and nonacoustical environments of the classrooms. Teachers agreed that the nonacoustical environments in the classrooms were fair, but that the acoustical environments had problems. Eight different classroom configurations were simulated to improve the acoustical environments, using the CATT room acoustical simulation program. When the surface absorption was increased, both the RT and speech levels decreased. RASTI was dependent on the volumes of the classrooms when the background noise levels were high; however, it depended on the total absorption of the classrooms when the background noise levels were low. Ceiling heights are critical as well. It is recommended that decreasing the volume of the classrooms is effective. Sound absorptive materials should be added to the walls or ceiling.
Litton, Edward; Elliott, Rosalind; Thompson, Kelly; Watts, Nicola; Seppelt, Ian; Webb, Steven A R
2017-06-01
To use clinically accessible tools to determine unit-level and individual patient factors associated with sound levels and sleep disruption in a range of representative ICUs. A cross-sectional, observational study. Australian and New Zealand ICUs. All patients 16 years or over occupying an ICU bed on one of two Point Prevalence study days in 2015. Ambient sound was measured for 1 minute using an application downloaded to a personal mobile device. Bedside nurses also recorded the total time and number of awakening for each patient overnight. The study included 539 participants with sound level recorded using an application downloaded to a personal mobile device from 39 ICUs. Maximum and mean sound levels were 78 dB (SD, 9) and 62 dB (SD, 8), respectively. Maximum sound levels were higher in ICUs with a sleep policy or protocol compared with those without maximum sound levels 81 dB (95% CI, 79-83) versus 77 dB (95% CI, 77-78), mean difference 4 dB (95% CI, 0-2), p < 0.001. There was no significant difference in sound levels regardless of single room occupancy, mechanical ventilation status, or illness severity. Clinical nursing staff in all 39 ICUs were able to record sleep assessment in 15-minute intervals. The median time awake and number of prolonged disruptions were 3 hours (interquartile range, 1-4) and three (interquartile range, 2-5), respectively. Across a large number of ICUs, patients were exposed to high sound levels and substantial sleep disruption irrespective of factors including previous implementation of a sleep policy. Sound and sleep measurement using simple and accessible tools can facilitate future studies and could feasibly be implemented into clinical practice.
Criteria for evaluating the condition of a tropical cyclone warning system.
Parker, D
1999-09-01
This paper evaluates the condition (i.e. health) of a tropical cyclone warning system (TCWS) during a 'quiet period' between infrequent intense cyclones. Capacity to make pre-disaster evaluations is important--disaster warning systems need to be in sound condition before, not after, disaster. The research--part of the UK's International Decade of Natural Disaster Reduction Flagship Programme--focuses upon an evaluatory method first used on flood warning systems. The Criteria-development Matrix comprises social, organisational and institutional criteria by which a TCWS may be assessed using a five-stage development scale. This method is used to evaluate Mauritius's TCWS using in-depth interview data. Ways to enhance the method and apply it to other disaster warning systems are discussed. The TCWS in Mauritius is a relatively sound one from which others can learn. Weaknesses requiring attention for Mauritius's TCWS to progress to an advanced level of development are identified.
A human-hearing-related prediction tool for soundscapes and community noise
NASA Astrophysics Data System (ADS)
Genuit, Klaus
2002-11-01
There are several methods of calculation available for the prediction of the A-weighted sound-pressure level of environmental noise, which are, however, not suitable for a qualified prediction of the residents' annoyance and physiological strain. The subjectively felt noise quality does not only depend on the A-weighted sound-pressure level, but also on other psychoacoustical parameters, such as loudness, roughness, sharpness, etc. In addition to these physical and psychoacoustical aspects of noise, the so-called psychological or cognitive aspects have to be considered, too, which means that the listeners' expectations, their mental attitude, as well as the information content of the noise finally influence the noise quality perceived by the individual persons. Within the scope of a research project SVEN (Sound Quality of Vehicle Exterior Noise), which is promoted by the EC, a new tool has been developed which allows a binaural simulation and prediction of the environmental noise to evaluate the influence of different contributions by the sound events with respect to the psychoacoustical parameters, the spatial distribution, movement, and frequency. By means of this tool it is now possible to consider completely new aspects regarding the audible perception of noise when establishing a soundscape or when planning community noise.
The Cost-Effectiveness of Lowering Permissible Noise Levels Around U.S. Airports
Jiao, Boshen; Zafari, Zafar; Will, Brian; Ruggeri, Kai
2017-01-01
Aircraft noise increases the risk of cardiovascular diseases and mental illness. The allowable limit for sound in the vicinity of an airport is 65 decibels (dB) averaged over a 24-h ‘day and night’ period (DNL) in the United States. We evaluate the trade-off between the cost and the health benefits of changing the regulatory DNL level from 65 dB to 55 dB using a Markov model. The study used LaGuardia Airport (LGA) as a case study. In compliance with 55 dB allowable limit of aircraft noise, sound insulation would be required for residential homes within the 55 dB to 65 dB DNL. A Markov model was built to assess the cost-effectiveness of installing sound insulation. One-way sensitivity analyses and Monte Carlo simulation were conducted to test uncertainty of the model. The incremental cost-effectiveness ratio of installing sound insulation for residents exposed to airplane noise from LGA was $11,163/QALY gained (95% credible interval: cost-saving and life-saving to $93,054/QALY gained). Changing the regulatory standard for noise exposure around airports from 65 dB to 55 dB comes at a very good value. PMID:29207473
The Cost-Effectiveness of Lowering Permissible Noise Levels Around U.S. Airports.
Jiao, Boshen; Zafari, Zafar; Will, Brian; Ruggeri, Kai; Li, Shukai; Muennig, Peter
2017-12-02
Aircraft noise increases the risk of cardiovascular diseases and mental illness. The allowable limit for sound in the vicinity of an airport is 65 decibels (dB) averaged over a 24-h 'day and night' period (DNL) in the United States. We evaluate the trade-off between the cost and the health benefits of changing the regulatory DNL level from 65 dB to 55 dB using a Markov model. The study used LaGuardia Airport (LGA) as a case study. In compliance with 55 dB allowable limit of aircraft noise, sound insulation would be required for residential homes within the 55 dB to 65 dB DNL. A Markov model was built to assess the cost-effectiveness of installing sound insulation. One-way sensitivity analyses and Monte Carlo simulation were conducted to test uncertainty of the model. The incremental cost-effectiveness ratio of installing sound insulation for residents exposed to airplane noise from LGA was $11,163/QALY gained (95% credible interval: cost-saving and life-saving to $93,054/QALY gained). Changing the regulatory standard for noise exposure around airports from 65 dB to 55 dB comes at a very good value.
Source levels of social sounds in migrating humpback whales (Megaptera novaeangliae).
Dunlop, Rebecca A; Cato, Douglas H; Noad, Michael J; Stokes, Dale M
2013-07-01
The source level of an animal sound is important in communication, since it affects the distance over which the sound is audible. Several measurements of source levels of whale sounds have been reported, but the accuracy of many is limited because the distance to the source and the acoustic transmission loss were estimated rather than measured. This paper presents measurements of source levels of social sounds (surface-generated and vocal sounds) of humpback whales from a sample of 998 sounds recorded from 49 migrating humpback whale groups. Sources were localized using a wide baseline five hydrophone array and transmission loss was measured for the site. Social vocalization source levels were found to range from 123 to 183 dB re 1 μPa @ 1 m with a median of 158 dB re 1 μPa @ 1 m. Source levels of surface-generated social sounds ("breaches" and "slaps") were narrower in range (133 to 171 dB re 1 μPa @ 1 m) but slightly higher in level (median of 162 dB re 1 μPa @ 1 m) compared to vocalizations. The data suggest that group composition has an effect on group vocalization source levels in that singletons and mother-calf-singing escort groups tend to vocalize at higher levels compared to other group compositions.
The Pre-School Child Near Environment: Variable Manipulation and Evaluation.
ERIC Educational Resources Information Center
Bartholomew, Robert; And Others
A study of the relationship between the behavior of preschool children (3-5-year age group) and the physical near environment has been initiated at Cornell. The illumination and sound levels, color, equipment, and spatial configurations in a nursery school room are to be varied, and systematic observational records will be kept of the level of…
DOT National Transportation Integrated Search
1975-01-01
This is a continuation of an earlier report in which the MICNOISE computer program for the prediction of highway noise was evaluated. The outputs of the MICNOISE program are the L50 and LI0 sound pressure levels, i.e., those levels experienced 50% an...
A social survey on the noise impact in open-plan working environments in China.
Zhang, Mei; Kang, Jian; Jiao, Fenglei
2012-11-01
The aim of this study is to reveal noise impact in open-plan working environments in China, through a series of questionnaire surveys and acoustic measurements in typical open-plan working environments. It has been found that compared to other physical environmental factors in open-plan working environments, people are much less satisfied with the acoustic environment. The noise impact in the surveyed working environments is rather significant, in terms of sound level inside the office, understanding of colleagues' conversation, and the use of background music such as music players. About 30-50% of the interviewees think that various noise sources inside and outside offices are 'very disturbing' and 'disturbing', and the most annoying sounds include noises from outside, ventilation systems, office equipment, and keyboard typing. Using higher panels to separate work space, or working in enclosed offices, are regarded as effective improvement measures, whereas introducing natural sounds to mask unwanted sounds seems to be not preferable. There are significant correlations between the evaluation of acoustic environment and office symptoms, including hypersensitivity to loud sounds, easily getting tired and depression. There are also significant correlations between evaluation of various acoustics-related factors and certain statements relating to job satisfaction, including sensitivity to noise, as well as whether conversations could be heard by colleagues. Copyright © 2012 Elsevier B.V. All rights reserved.
Radiated BPF sound measurement of centrifugal compressor
NASA Astrophysics Data System (ADS)
Ohuchida, S.; Tanaka, K.
2013-12-01
A technique to measure radiated BPF sound from an automotive turbocharger compressor impeller is proposed in this paper. Where there are high-level background noises in the measurement environment, it is difficult to discriminate the target component from the background. Since the effort of measuring BPF sound was taken in a room with such condition in this study, no discrete BPF peak was initially found on the sound spectrum. Taking its directionality into consideration, a microphone covered with a parabolic cone was selected and using this technique, the discrete peak of BPF was clearly observed. Since the level of measured sound was amplified due to the area-integration effect, correction was needed to obtain the real level. To do so, sound measurements with and without a parabolic cone were conducted for the fixed source and their level differences were used as correction factors. Consideration is given to the sound propagation mechanism utilizing measured BPF as well as the result of a simple model experiment. The present method is generally applicable to sound measurements conducted with a high level of background noise.
Limitations on the upconversion of ion sound to Langmuir turbulence
NASA Technical Reports Server (NTRS)
Vlahos, L.; Papadopoulos, K.
1982-01-01
The weak turbulence theory of Tsytovich, Stenflo and Wilhelmsson (1981) for evaluation of the nonlinear transfer of ion acoustic waves to Langmuir waves is shown to be limited in its region of validity to the level of ion acoustic waves. It is also demonstrated that, in applying the upconversion of ion sound to Langmuir waves for electron acceleration, nonlinear scattering should be self-consistently included, with a suppression of the upconversion process resulting. The impossibility of accelerating electrons by such a process for any reasonable physical system is thereby reaffirmed.
Affective Evaluations of and Reactions to Exterior and Interior Vehicle Auditory Quality
NASA Astrophysics Data System (ADS)
Västfjäll, D.; Gulbol, M.-A.; Kleiner, M.; Gärling, T.
2002-08-01
Affective reactions to and evaluations of auditory stimuli are fundamental components of human perception. In three experiments, participants rated their affective reactions (how pleasant I feel) and preferences for these affective reactions (how much I like the way I feel) as well as affective evaluations (how pleasant the sound is) to interior and exterior binaurally recorded vehicle sounds varying in physical properties. Consistent with previous research, it was found that the orthogonal affect dimensions of valence (unpleasant-pleasant) and arousal or activation (deactivation-activation) discriminated between affective reactions induced by the different qualities of the sounds. Moreover, preference for affective reactions was related to both valence and activation. Affective evaluations (powerful-powerless/passive-active and unpleasant-pleasant) correlated significantly with affective reactions to the same sounds in both within-subjects and between-subjects designs. Standard sound quality metrics derived from the sounds correlated, however, poorly with the affective ratings of interior sounds and only moderately with affective ratings of exterior sounds. Taken together, the results suggest that affect is an important component in product auditory quality optimization.
Lee, Hyun-Ho; Lee, Sang-Kwon
2009-09-01
Booming sound is one of the important sounds in a passenger car. The aim of the paper is to develop the objective evaluation method of interior booming sound. The development method is based on the sound metrics and ANN (artificial neural network). The developed method is called the booming index. Previous work maintained that booming sound quality is related to loudness and sharpness--the sound metrics used in psychoacoustics--and that the booming index is developed by using the loudness and sharpness for a signal within whole frequency between 20 Hz and 20 kHz. In the present paper, the booming sound quality was found to be effectively related to the loudness at frequencies below 200 Hz; thus the booming index is updated by using the loudness of the signal filtered by the low pass filter at frequency under 200 Hz. The relationship between the booming index and sound metric is identified by an ANN. The updated booming index has been successfully applied to the objective evaluation of the booming sound quality of mass-produced passenger cars.
Tanaka, Tagayasu; Inaba, Ryoichi; Aoyama, Atsuhito
2016-01-01
Objectives: This study investigated the actual situation of noise and low-frequency sounds in firework events and their impact on pyrotechnicians. Methods: Data on firework noise and low-frequency sounds were obtained at a point located approximately 100 m away from the launch site of a firework display held in "A" City in 2013. We obtained the data by continuously measuring and analyzing the equivalent continuous sound level (Leq) and the one-third octave band of the noise and low-frequency sounds emanating from the major firework detonations, and predicted sound levels at the original launch site. Results: Sound levels of 100-115 dB and low-frequency sounds of 100-125 dB were observed at night. The maximum and mean Leq values were 97 and 95 dB, respectively. The launching noise level predicted from the sounds (85 dB) at the noise measurement point was 133 dB. Occupational exposure to noise for pyrotechnicians at the remote operation point (located 20-30 m away from the launch site) was estimated to be below 100 dB. Conclusions: Pyrotechnicians are exposed to very loud noise (>100 dB) at the launch point. We believe that it is necessary to implement measures such as fixing earplugs or earmuffs, posting a warning at the workplace, and executing a remote launching operation to prevent hearing loss caused by occupational exposure of pyrotechnicians to noise. It is predicted that both sound levels and low-frequency sounds would be reduced by approximately 35 dB at the remote operation site. PMID:27725489
Tanaka, Tagayasu; Inaba, Ryoichi; Aoyama, Atsuhito
2016-11-29
This study investigated the actual situation of noise and low-frequency sounds in firework events and their impact on pyrotechnicians. Data on firework noise and low-frequency sounds were obtained at a point located approximately 100 m away from the launch site of a firework display held in "A" City in 2013. We obtained the data by continuously measuring and analyzing the equivalent continuous sound level (Leq) and the one-third octave band of the noise and low-frequency sounds emanating from the major firework detonations, and predicted sound levels at the original launch site. Sound levels of 100-115 dB and low-frequency sounds of 100-125 dB were observed at night. The maximum and mean Leq values were 97 and 95 dB, respectively. The launching noise level predicted from the sounds (85 dB) at the noise measurement point was 133 dB. Occupational exposure to noise for pyrotechnicians at the remote operation point (located 20-30 m away from the launch site) was estimated to be below 100 dB. Pyrotechnicians are exposed to very loud noise (>100 dB) at the launch point. We believe that it is necessary to implement measures such as fixing earplugs or earmuffs, posting a warning at the workplace, and executing a remote launching operation to prevent hearing loss caused by occupational exposure of pyrotechnicians to noise. It is predicted that both sound levels and low-frequency sounds would be reduced by approximately 35 dB at the remote operation site.
[HYGIENIC ASSESSMENT OF NOISE FACTOR OF THE LARGE CITY].
Chubirko, M L; Stepkin, Yu I; Seredenko, O V
2015-01-01
The article is devoted to the problem of the negative impact of traffic noise on the health and living conditions of the population in conditions of the large city. Every day on the streets there are appeared more and more different modes of transport, and to date almost all transportation network has reached his traffic performance. The increase in traffic noise certainly has an impact on the human body. The most common and intense noise is caused by the traffic of urban automobile and electric transport. This is explained by the existence of the heavy traffic (2-3 thousand crews/h) on almost all main roads in historically emerged parts of the city. In addition, sources of external noise in the city can be a railway running in residential zone, access roads, industrial enterprises, located in close proximity to residential areas and on the borders of residential zones, planes of military and civil aviation. For the evaluation of the different noises sound levels were measured with the use of sound level meters. The most common parameter for the assessment ofthe noise generatedfrom motor vehicles on residential areas and usedfor the noise characteristics of the traffic flows, is the equivalent sound level/A EQ dB. This parameter is used in the majority of normative-technical documentation as hygienic noise standard. With the aim of the assessment of noise exposure there were selected 122 control points at intersections of roads of different traffic performance where there were made instrumental measurements the equivalent sound level, followed by its comparison with permissible levels.
Loiselle, Louise H; Dorman, Michael F; Yost, William A; Cook, Sarah J; Gifford, Rene H
2016-08-01
To assess the role of interaural time differences and interaural level differences in (a) sound-source localization, and (b) speech understanding in a cocktail party listening environment for listeners with bilateral cochlear implants (CIs) and for listeners with hearing-preservation CIs. Eleven bilateral listeners with MED-EL (Durham, NC) CIs and 8 listeners with hearing-preservation CIs with symmetrical low frequency, acoustic hearing using the MED-EL or Cochlear device were evaluated using 2 tests designed to task binaural hearing, localization, and a simulated cocktail party. Access to interaural cues for localization was constrained by the use of low-pass, high-pass, and wideband noise stimuli. Sound-source localization accuracy for listeners with bilateral CIs in response to the high-pass noise stimulus and sound-source localization accuracy for the listeners with hearing-preservation CIs in response to the low-pass noise stimulus did not differ significantly. Speech understanding in a cocktail party listening environment improved for all listeners when interaural cues, either interaural time difference or interaural level difference, were available. The findings of the current study indicate that similar degrees of benefit to sound-source localization and speech understanding in complex listening environments are possible with 2 very different rehabilitation strategies: the provision of bilateral CIs and the preservation of hearing.
Ultrasound pressure distributions generated by high frequency transducers in large reactors.
Leong, Thomas; Coventry, Michael; Swiergon, Piotr; Knoerzer, Kai; Juliano, Pablo
2015-11-01
The performance of an ultrasound reactor chamber relies on the sound pressure level achieved throughout the system. The active volume of a high frequency ultrasound chamber can be determined by the sound pressure penetration and distribution provided by the transducers. This work evaluated the sound pressure levels and uniformity achieved in water by selected commercial scale high frequency plate transducers without and with reflector plates. Sound pressure produced by ultrasonic plate transducers vertically operating at frequencies of 400 kHz (120 W) and 2 MHz (128 W) was characterized with hydrophones in a 2 m long chamber and their effective operating distance across the chamber's vertical cross section was determined. The 2 MHz transducer produced the highest pressure amplitude near the transducer surface, with a sharp decline of approximately 40% of the sound pressure occurring in the range between 55 and 155 mm from the transducer. The placement of a reflector plate 500 mm from the surface of the transducer was shown to improve the sound pressure uniformity of 2 MHz ultrasound. Ultrasound at 400 kHz was found to penetrate the fluid up to 2 m without significant losses. Furthermore, 400 kHz ultrasound generated a more uniform sound pressure distribution regardless of the presence or absence of a reflector plate. The choice of the transducer distance to the opposite reactor wall therefore depends on the transducer plate frequency selected. Based on pressure measurements in water, large scale 400 kHz reactor designs can consider larger transducer distance to opposite wall and larger active cross-section, and therefore can reach higher volumes than when using 2 MHz transducer plates. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.
Visualizing Sound: Demonstrations to Teach Acoustic Concepts
NASA Astrophysics Data System (ADS)
Rennoll, Valerie
Interference, a phenomenon in which two sound waves superpose to form a resultant wave of greater or lower amplitude, is a key concept when learning about the physics of sound waves. Typical interference demonstrations involve students listening for changes in sound level as they move throughout a room. Here, new tools are developed to teach this concept that provide a visual component, allowing individuals to see changes in sound level on a light display. This is accomplished using a microcontroller that analyzes sound levels collected by a microphone and displays the sound level in real-time on an LED strip. The light display is placed on a sliding rail between two speakers to show the interference occurring between two sound waves. When a long-exposure photograph is taken of the light display being slid from one end of the rail to the other, a wave of the interference pattern can be captured. By providing a visual component, these tools will help students and the general public to better understand interference, a key concept in acoustics.
Behavioral response of manatees to variations in environmental sound levels
Miksis-Olds, Jennifer L.; Wagner, Tyler
2011-01-01
Florida manatees (Trichechus manatus latirostris) inhabit coastal regions because they feed on the aquatic vegetation that grows in shallow waters, which are the same areas where human activities are greatest. Noise produced from anthropogenic and natural sources has the potential to affect these animals by eliciting responses ranging from mild behavioral changes to extreme aversion. Sound levels were calculated from recordings made throughout behavioral observation periods. An information theoretic approach was used to investigate the relationship between behavior patterns and sound level. Results indicated that elevated sound levels affect manatee activity and are a function of behavioral state. The proportion of time manatees spent feeding and milling changed in response to sound level. When ambient sound levels were highest, more time was spent in the directed, goal-oriented behavior of feeding, whereas less time was spent engaged in undirected behavior such as milling. This work illustrates how shifts in activity of individual manatees may be useful parameters for identifying impacts of noise on manatees and might inform population level effects.
Casper, Brandon M.; Popper, Arthur N.; Matthews, Frazer; Carlson, Thomas J.; Halvorsen, Michele B.
2012-01-01
Juvenile Chinook salmon, Oncorhynchus tshawytscha, were exposed to simulated high intensity pile driving signals to evaluate their ability to recover from barotrauma injuries. Fish were exposed to one of two cumulative sound exposure levels for 960 pile strikes (217 or 210 dB re 1 µPa2·s SELcum; single strike sound exposure levels of 187 or 180 dB re 1 µPa2⋅s SELss respectively). This was followed by an immediate assessment of injuries, or assessment 2, 5, or 10 days post-exposure. There were no observed mortalities from the pile driving sound exposure. Fish exposed to 217 dB re 1 µPa2·s SELcum displayed evidence of healing from injuries as post-exposure time increased. Fish exposed to 210 dB re 1 µPa2·s SELcum sustained minimal injuries that were not significantly different from control fish at days 0, 2, and 10. The exposure to 210 dB re 1 µPa2·s SELcum replicated the findings in a previous study that defined this level as the threshold for onset of injury. Furthermore, these data support the hypothesis that one or two Mild injuries resulting from pile driving exposure are unlikely to affect the survival of the exposed animals, at least in a laboratory environment. PMID:22745794
Poganiatz, I; Wagner, H
2001-04-01
Interaural level differences play an important role for elevational sound localization in barn owls. The changes of this cue with sound location are complex and frequency dependent. We exploited the opportunities offered by the virtual space technique to investigate the behavioral relevance of the overall interaural level difference by fixing this parameter in virtual stimuli to a constant value or introducing additional broadband level differences to normal virtual stimuli. Frequency-specific monaural cues in the stimuli were not manipulated. We observed an influence of the broadband interaural level differences on elevational, but not on azimuthal sound localization. Since results obtained with our manipulations explained only part of the variance in elevational turning angle, we conclude that frequency-specific cues are also important. The behavioral consequences of changes of the overall interaural level difference in a virtual sound depended on the combined interaural time difference contained in the stimulus, indicating an indirect influence of temporal cues on elevational sound localization as well. Thus, elevational sound localization is influenced by a combination of many spatial cues including frequency-dependent and temporal features.
Autonomic, endocrine and behavioural responses to thunder in laboratory and companion dogs.
Franzini de Souza, Carla Caroline; Maccariello, Carolina Elisabetta Martins; Dias, Daniel Penteado Martins; Almeida, Norma Aparecida Dos Santos; Medeiros, Magda Alves de
2017-02-01
Dogs are highly sensitive to sound stimuli, especially fireworks, firearms, and thunder, and therefore these sounds are used as models of stress reactivity in dogs. Companion and laboratory dogs may respond differently to stressful stimuli, due to differences in management and their relationship with humans. Therefore, the reactivity of beagle dogs (laboratory) and companion dogs to an acute acoustic stress model was studied by analysing the heart rate variability (HRV; cardiac interval values), serum cortisol levels and various behavioural parameters. Eight beagles and six privately owned dogs with no history of phobia to thunder were used. The sound stimulus consisted of a standardized recording of thunder for 2.5min with a maximum intensity of 103-104dB. To evaluate the HRV, cardiac intervals were recorded using a frequency meter (Polar RS800CX model), and later the data were analysed using CardioSeries 2.4.1 software. In both laboratory and companion dogs, thunder promoted an increase in the power of the LF band of the cardiac interval spectrum, in the LF/HF ratio and in the HR, and a decrease in the power of the HF band of the cardiac interval spectrum. Companion dogs showed higher cortisol levels, than beagles, independently of the time point studied and a significant increase in the cortisol levels 15min after acoustic stress, while beagles did not show any alterations in their cortisol levels in response to the sound. On the other hand, beagles showed higher scores in the trembling, hiding, vigilance, running, salivation, bolting and startle parameters than companion dogs. Our results showed that independently of the sound stimulus, companion dogs had higher cortisol levels than laboratory dogs. Furthermore, the sound stimulus induced a marked autonomic imbalance towards sympathetic predominance in both laboratory and companion dogs. However a significant increase in the cortisol was observed only in companion dogs. On the other hand, in general the behavioural response was more pronounced in laboratory dogs than in companion dogs. Copyright © 2016 Elsevier Inc. All rights reserved.
Restoring speech perception with cochlear implants by spanning defective electrode contacts.
Frijns, Johan H M; Snel-Bongers, Jorien; Vellinga, Dirk; Schrage, Erik; Vanpoucke, Filiep J; Briaire, Jeroen J
2013-04-01
Even with six defective contacts, spanning can largely restore speech perception with the HiRes 120 speech processing strategy to the level supported by an intact electrode array. Moreover, the sound quality is not degraded. Previous studies have demonstrated reduced speech perception scores (SPS) with defective contacts in HiRes 120. This study investigated whether replacing defective contacts by spanning, i.e. current steering on non-adjacent contacts, is able to restore speech recognition to the level supported by an intact electrode array. Ten adult cochlear implant recipients (HiRes90K, HiFocus1J) with experience with HiRes 120 participated in this study. Three different defective electrode arrays were simulated (six separate defective contacts, three pairs or two triplets). The participants received three take-home strategies and were asked to evaluate the sound quality in five predefined listening conditions. After 3 weeks, SPS were evaluated with monosyllabic words in quiet and in speech-shaped background noise. The participants rated the sound quality equal for all take-home strategies. SPS with background noise were equal for all conditions tested. However, SPS in quiet (85% phonemes correct on average with the full array) decreased significantly with increasing spanning distance, with a 3% decrease for each spanned contact.
NASA Astrophysics Data System (ADS)
Lau, S. F.; Zainulabidin, M. H.; Yahya, M. N.; Zaman, I.; Azmir, N. A.; Madlan, M. A.; Ismon, M.; Kasron, M. Z.; Ismail, A. E.
2017-10-01
Giving a room proper acoustic treatment is both art and science. Acoustic design brings comfort in the built environment and reduces noise level by using sound absorbers. There is a need to give a room acoustic treatment by installing absorbers in order to decrease the reverberant sound. However, they are usually high in price which cost much for installation and there is no system to locate the optimum number and placement of sound absorbers. It would be a waste if the room is overly treated with absorbers or cause improper treatment if the room is treated with insufficient absorbers. This study aims to determine the amount of sound absorbers needed and optimum location of sound absorbers placement in order to reduce the overall sound pressure level in specified room by using ANSYS APDL software. The size of sound absorbers needed is found to be 11 m 2 by using Sabine equation and different unit sets of absorbers are applied on walls, each with the same total areas to investigate the best configurations. All three sets (single absorber, 11 absorbers and 44 absorbers) has successfully treating the room by reducing the overall sound pressure level. The greatest reduction in overall sound pressure level is that of 44 absorbers evenly distributed around the walls, which has reduced as much as 24.2 dB and the least effective configuration is single absorber whereby it has reduced the overall sound pressure level by 18.4 dB.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bianco, Laura; Friedrich, Katja; Wilczak, James M.
To assess current remote-sensing capabilities for wind energy applications, a remote-sensing system evaluation study, called XPIA (eXperimental Planetary boundary layer Instrument Assessment), was held in the spring of 2015 at NOAA's Boulder Atmospheric Observatory (BAO) facility. Several remote-sensing platforms were evaluated to determine their suitability for the verification and validation processes used to test the accuracy of numerical weather prediction models.The evaluation of these platforms was performed with respect to well-defined reference systems: the BAO's 300 m tower equipped at six levels (50, 100, 150, 200, 250, and 300 m) with 12 sonic anemometers and six temperature ( T) andmore » relative humidity (RH) sensors; and approximately 60 radiosonde launches.In this study we first employ these reference measurements to validate temperature profiles retrieved by two co-located microwave radiometers (MWRs) as well as virtual temperature ( T v) measured by co-located wind profiling radars equipped with radio acoustic sounding systems (RASSs). Results indicate a mean absolute error (MAE) in the temperature retrieved by the microwave radiometers below 1.5 K in the lowest 5?km of the atmosphere and a mean absolute error in the virtual temperature measured by the radio acoustic sounding systems below 0.8 K in the layer of the atmosphere covered by these measurements (up to approximately 1.6-2 km). We also investigated the benefit of the vertical velocity correction applied to the speed of sound before computing the virtual temperature by the radio acoustic sounding systems. We find that using this correction frequently increases the RASS error, and that it should not be routinely applied to all data.Water vapor density (WVD) profiles measured by the MWRs were also compared with similar measurements from the soundings, showing the capability of MWRs to follow the vertical profile measured by the sounding and finding a mean absolute error below 0.5 g m -3 in the lowest 5 km of the atmosphere. However, the relative humidity profiles measured by the microwave radiometer lack the high-resolution details available from radiosonde profiles. Furthermore, an encouraging and significant finding of this study was that the coefficient of determination between the lapse rate measured by the microwave radiometer and the tower measurements over the tower levels between 50 and 300 m ranged from 0.76 to 0.91, proving that these remote-sensing instruments can provide accurate information on atmospheric stability conditions in the lower boundary layer.« less
Bianco, Laura; Friedrich, Katja; Wilczak, James M.; ...
2017-05-09
To assess current remote-sensing capabilities for wind energy applications, a remote-sensing system evaluation study, called XPIA (eXperimental Planetary boundary layer Instrument Assessment), was held in the spring of 2015 at NOAA's Boulder Atmospheric Observatory (BAO) facility. Several remote-sensing platforms were evaluated to determine their suitability for the verification and validation processes used to test the accuracy of numerical weather prediction models.The evaluation of these platforms was performed with respect to well-defined reference systems: the BAO's 300 m tower equipped at six levels (50, 100, 150, 200, 250, and 300 m) with 12 sonic anemometers and six temperature ( T) andmore » relative humidity (RH) sensors; and approximately 60 radiosonde launches.In this study we first employ these reference measurements to validate temperature profiles retrieved by two co-located microwave radiometers (MWRs) as well as virtual temperature ( T v) measured by co-located wind profiling radars equipped with radio acoustic sounding systems (RASSs). Results indicate a mean absolute error (MAE) in the temperature retrieved by the microwave radiometers below 1.5 K in the lowest 5?km of the atmosphere and a mean absolute error in the virtual temperature measured by the radio acoustic sounding systems below 0.8 K in the layer of the atmosphere covered by these measurements (up to approximately 1.6-2 km). We also investigated the benefit of the vertical velocity correction applied to the speed of sound before computing the virtual temperature by the radio acoustic sounding systems. We find that using this correction frequently increases the RASS error, and that it should not be routinely applied to all data.Water vapor density (WVD) profiles measured by the MWRs were also compared with similar measurements from the soundings, showing the capability of MWRs to follow the vertical profile measured by the sounding and finding a mean absolute error below 0.5 g m -3 in the lowest 5 km of the atmosphere. However, the relative humidity profiles measured by the microwave radiometer lack the high-resolution details available from radiosonde profiles. Furthermore, an encouraging and significant finding of this study was that the coefficient of determination between the lapse rate measured by the microwave radiometer and the tower measurements over the tower levels between 50 and 300 m ranged from 0.76 to 0.91, proving that these remote-sensing instruments can provide accurate information on atmospheric stability conditions in the lower boundary layer.« less
NASA Astrophysics Data System (ADS)
Bianco, Laura; Friedrich, Katja; Wilczak, James M.; Hazen, Duane; Wolfe, Daniel; Delgado, Ruben; Oncley, Steven P.; Lundquist, Julie K.
2017-05-01
To assess current remote-sensing capabilities for wind energy applications, a remote-sensing system evaluation study, called XPIA (eXperimental Planetary boundary layer Instrument Assessment), was held in the spring of 2015 at NOAA's Boulder Atmospheric Observatory (BAO) facility. Several remote-sensing platforms were evaluated to determine their suitability for the verification and validation processes used to test the accuracy of numerical weather prediction models.The evaluation of these platforms was performed with respect to well-defined reference systems: the BAO's 300 m tower equipped at six levels (50, 100, 150, 200, 250, and 300 m) with 12 sonic anemometers and six temperature (T) and relative humidity (RH) sensors; and approximately 60 radiosonde launches.In this study we first employ these reference measurements to validate temperature profiles retrieved by two co-located microwave radiometers (MWRs) as well as virtual temperature (Tv) measured by co-located wind profiling radars equipped with radio acoustic sounding systems (RASSs). Results indicate a mean absolute error (MAE) in the temperature retrieved by the microwave radiometers below 1.5 K in the lowest 5 km of the atmosphere and a mean absolute error in the virtual temperature measured by the radio acoustic sounding systems below 0.8 K in the layer of the atmosphere covered by these measurements (up to approximately 1.6-2 km). We also investigated the benefit of the vertical velocity correction applied to the speed of sound before computing the virtual temperature by the radio acoustic sounding systems. We find that using this correction frequently increases the RASS error, and that it should not be routinely applied to all data.Water vapor density (WVD) profiles measured by the MWRs were also compared with similar measurements from the soundings, showing the capability of MWRs to follow the vertical profile measured by the sounding and finding a mean absolute error below 0.5 g m-3 in the lowest 5 km of the atmosphere. However, the relative humidity profiles measured by the microwave radiometer lack the high-resolution details available from radiosonde profiles. An encouraging and significant finding of this study was that the coefficient of determination between the lapse rate measured by the microwave radiometer and the tower measurements over the tower levels between 50 and 300 m ranged from 0.76 to 0.91, proving that these remote-sensing instruments can provide accurate information on atmospheric stability conditions in the lower boundary layer.
NASA Astrophysics Data System (ADS)
Spence, Heather Ruth
Sound is the primary sensory modality for dolphins, yet policies mitigating anthropogenic sound exposure are limited in wild populations and even fewer noise policies or guidelines have been developed for governing dolphin welfare under human care. Concerns have been raised that dolphins under human care live in facilities that are too noisy, or are too acoustically sterile. However, these claims have not been evaluated to characterize facility soundscapes, and further, how they compare to wild soundscapes. The soundscape of a wild dolphin habitat off the coast of Quintana, Roo, Mexico was characterized based on Passive Acoustic Monitoring (PAM) recordings over one year. Snapping shrimp were persistent and broadband, following a diel pattern. Fish sound production was pulsed and prominent in low frequencies (100 -- 1000 Hz), and abiotic surface wave action contributed to noise in higher frequencies (15 -- 28 kHz). Boat motors were the main anthropogenic sound source. While sporadic, boat motors were responsible for large spikes in the noise, sometimes exceeding the ambient noise (in the absence of a boat) by 20 dB root-mean-squared sound pressure level, and potentially higher at closer distances. Boat motor sounds can potentially mask cues and communication sounds of dolphins. The soundscapes of four acoustically distinct outdoor dolphin facilities in Quintana Roo, Mexico were also characterized based on PAM, and findings compared with one another and with the measurements from the wild dolphin habitat. Recordings were made for at least 24 hours to encompass the range of daily activities. The four facilities differed in non-dolphin species present (biological sounds), bathymetry complexity, and method of water circulation. It was hypothesized that the greater the biological and physical differences of a pool from the ocean habitat, the greater the acoustic differences would be from the natural environment. Spectral analysis and audio playback revealed that the site most biologically and physically distinct from the ocean habitat also differed greatly from the other sites acoustically, with the most common and high amplitude sound being pump noise versus biological sounds at the other sites. Overall the dolphin facilities were neither clearly noisier nor more sterile than the wild site, but rather differed in particular characteristics. The findings are encouraging for dolphin welfare for several reasons. Sound levels measured were unlikely to cause threshold shifts in hearing. At three of four facilities, prominent biological sounds in the wild site -- snapping shrimp and fish sounds -- were present, meaning that the dolphins at these facilities are experiencing biotic features of the soundscape they would experience in the wild. Additionally, the main anthropogenic sounds experienced at the facilities (construction and cleaning sounds) did not reach the levels of the anthropogenic sounds experienced at the wild site (boat motor sounds), and the highest noise levels for anthropogenic sounds fall outside the dolphins' most sensitive range of hearing. However, there are anthropogenic contributors to the soundscape that are of particular interest and possible concern that should be investigated further, particularly pump noise and periodic or intermittent construction noise. These factors need to be considered on a facility-by-facility basis and appropriate mitigation procedures incorporated in animal handling to mitigate potential responses to planned or anticipated sound producing events, e.g. animal relocation or buffering sound producing activities. The central role of bioacoustics for dolphins means that PAM is a basic life support requirement along with water and food testing. Periodic noise is of highest concern, and PAM is needed to inform mitigation of noise from periodic sources. Priority actions are more widespread and long-term standardized monitoring, further research on habituation, preference, coupling and pool acoustics, implementation of acoustics training, standardization of measurements, and improved information access.
49 CFR 227.115 - Hearing protectors.
Code of Federal Regulations, 2011 CFR
2011-10-01
... employees exposed to sound levels that meet or exceed the action level. (c) Required use at action level. A railroad shall require the use of hearing protectors when an employee is exposed to sound levels that meet... hearing protectors when an employee is exposed to sound levels equivalent to an 8-hour TWA of 90 dB(A) or...
Influence of Gestational Age and Postnatal Age on Speech Sound Processing in NICU infants
Key, Alexandra P.F.; Lambert, E. Warren; Aschner, Judy L.; Maitre, Nathalie L.
2012-01-01
The study examined the effect of gestational (GA) and postnatal (PNA) age on speech sound perception in infants. Auditory ERPs were recorded in response to speech sounds (CV syllables) in 50 infant NICU patients (born at 24–40 weeks gestation) prior to discharge. Efficiency of speech perception was quantified as absolute difference in mean amplitudes of ERPs in response to vowel (/a/–/u/) and consonant (/b/–/g/, /d/–/g/) contrasts within 150–250, 250–400, 400–700 ms after stimulus onset. Results indicated that both GA and PNA affected speech sound processing. These effects were more pronounced for consonant than vowel contrasts. Increasing PNA was associated with greater sound discrimination in infants born at or after 30 weeks GA, while minimal PNA-related changes were observed for infants with GA less than 30 weeks. Our findings suggest that a certain level of brain maturity at birth is necessary to benefit from postnatal experience in the first 4 months of life, and both gestational and postnatal ages need to be considered when evaluating infant brain responses. PMID:22332725
Sound field simulation and acoustic animation in urban squares
NASA Astrophysics Data System (ADS)
Kang, Jian; Meng, Yan
2005-04-01
Urban squares are important components of cities, and the acoustic environment is important for their usability. While models and formulae for predicting the sound field in urban squares are important for their soundscape design and improvement, acoustic animation tools would be of great importance for designers as well as for public participation process, given that below a certain sound level, the soundscape evaluation depends mainly on the type of sounds rather than the loudness. This paper first briefly introduces acoustic simulation models developed for urban squares, as well as empirical formulae derived from a series of simulation. It then presents an acoustic animation tool currently being developed. In urban squares there are multiple dynamic sound sources, so that the computation time becomes a main concern. Nevertheless, the requirements for acoustic animation in urban squares are relatively low compared to auditoria. As a result, it is important to simplify the simulation process and algorithms. Based on a series of subjective tests in a virtual reality environment with various simulation parameters, a fast simulation method with acceptable accuracy has been explored. [Work supported by the European Commission.
NASA Technical Reports Server (NTRS)
Yamamoto, K.; Janardan, B. A.; Brausch, J. F.; Hoerst, D. J.; Price, A. O.
1984-01-01
Parameters which contribute to supersonic jet shock noise were investigated for the purpose of determining means to reduce such noise generation to acceptable levels. Six dual-stream test nozzles with varying flow passage and plug closure designs were evaluated under simulated flight conditions in an anechoic chamber. All nozzles had combined convergent-divergent or convergent flow passages. Acoustic behavior as a function of nozzle flow passage geometry was measured. The acoustic data consist primarily of 1/3 octave band sound pressure levels and overall sound pressure levels. Detailed schematics and geometric characteristics of the six scale model nozzle configurations and acoustic test point definitions are presented. Tabulation of aerodynamic test conditions and a computer listing of the measured acoustic data are displayed.
Acoustical Modifications for the Classroom.
ERIC Educational Resources Information Center
Crandell, Carl C.; Smaldino, Joseph J.
1999-01-01
This article reviews procedures for evaluating, measuring, and modifying noise and reverberation levels in the classroom environment. Recommendations include: relocating children away from high noise sources, such as fans, air conditioners, heating ducts, and faulty lighting fixtures, using sound-absorbing materials, using acoustical ceiling tile…
Darcy, Ashley E; Hancock, Lauren E; Ware, Emily J
2008-10-01
To examine the baseline acoustic environment in several mid-Atlantic region neonatal intensive care units (NICUs) and investigate the perceived factors contributing to noise levels in these NICUs. Quantitative data were collected from 3 urban, mid-Atlantic level IIIB and level IIIC NICUs. Qualitative data were collected via interview from 2 RNs employed in each of the study NICUs. This was an exploratory descriptive study utilizing a mixed-methods approach. A quantitative method was used for sound-level data collection, and a qualitative method was utilized during interviews with nurses to examine perceptions of factors contributing to noise. Ambient sound levels, measured in decibels, were taken at 5-minute intervals over a 2-hour period during both day and night shifts in a central location at each NICU. In addition, nurses were interviewed using a standardized interview questionnaire, and these interviews were then reviewed to determine themes regarding perceived factors contributing to sound levels. Hourly mean sound levels in each NICU ranged from 53.9 dB to 60.6 dB, with no statistically significant difference between noise levels recorded on day shift versus night shift, and no statistically significant difference among sites. Qualitative data showed that nurses' believed day shift to be louder than night shift and many perceived their own NICU as "pretty quiet." Key contributing factors to increased sound levels were stated as monitors or alarms, performing invasive procedures, presence of family, nurses or doctors giving report or rounds, and ringing phones. Noise levels were found to be above the American Academy of Pediatrics-recommended 45-dB level and often louder than the 50-dB level, which should not be exceeded more than 10% of the time. The recommended impulse maximum of 65 dB was also exceeded. Environmental Protection Agency recommendations for hospitals include sound levels no louder than 35 dB on night shift; this standard was also violated. Elevated sound levels need to be addressed in individual NICUs around the country. Further exploratory studies, as well as research regarding effective methods of decreasing sound levels in the NICU environment, are necessary. NICUs can implement behavioral and structural changes that can decrease the sound levels in the NICU environment and decrease the potential for exposure of patients to the harmful physiological effects of increased sound levels.
Darcy, Ashley E; Hancock, Lauren E; Ware, Emily J
2008-06-01
To examine the baseline acoustic environment in several mid-Atlantic region neonatal intensive care units (NICUs) and investigate the perceived factors contributing to noise levels in these NICUs. Quantitative data were collected from 3 urban, mid-Atlantic level IIIB and level IIIC NICUs. Qualitative data were collected via interview from 2 RNs employed in each of the study NICUs. This was an exploratory descriptive study utilizing a mixed-methods approach. A quantitative method was used for sound-level data collection, and a qualitative method was utilized during interviews with nurses to examine perceptions of factors contributing to noise. Ambient sound levels, measured in decibels, were taken at 5-minute intervals over a 2-hour period during both day and night shifts in a central location at each NICU. In addition, nurses were interviewed using a standardized interview questionnaire, and these interviews were then reviewed to determine themes regarding perceived factors contributing to sound levels. Hourly mean sound levels in each NICU ranged from 53.9 dB to 60.6 dB, with no statistically significant difference between noise levels recorded on day shift versus night shift, and no statistically significant difference among sites. Qualitative data showed that nurses' believed day shift to be louder than night shift and many perceived their own NICU as "pretty quiet." Key contributing factors to increased sound levels were stated as monitors or alarms, performing invasive procedures, presence of family, nurses or doctors giving report or rounds, and ringing phones. Noise levels were found to be above the American Academy of Pediatrics--recommended 45-dB level and often louder than the 50-dB level, which should not be exceeded more than 10% of the time. The recommended impulse maximum of 65 dB was also exceeded. Environmental Protection Agency recommendations for hospitals include sound levels no louder than 35 dB on night shift; this standard was also violated. Elevated sound levels need to be addressed in individual NICUs around the country. Further exploratory studies, as well as research regarding effective methods of decreasing sound levels in the NICU environment, are necessary. NICUs can implement behavioral and structural changes that can decrease the sound levels in the NICU environment and decrease the potential for exposure of patients to the harmful physiological effects of increased sound levels.
Hearing in nonprofessional pop/rock musicians.
Schmuziger, Nicolas; Patscheke, Jochen; Probst, Rudolf
2006-08-01
The purpose of this study was to evaluate the hearing and subjective auditory symptoms in a group of nonprofessional pop/rock musicians who had experienced repeated exposures to intense sound levels during at least 5 yr of musical activity. An evaluation of both ears in 42 nonprofessional pop/rock musicians included pure-tone audiometry in the conventional and extended high-frequency range, the measurement of uncomfortable loudness levels, and an assessment of tinnitus and hypersensitivity to sound. Exclusion criteria were (a) the occurrence of acoustic trauma, (b) excessive noise exposure during occupational activities, (c) a history of recurrent otitis media, (d) previous ear surgery, (e) a fracture of the cranium, (f) ingestion of potentially ototoxic drugs, and (g) reported hearing difficulties within the immediate family. These audiometric results were then compared with a control group of 20 otologically normal young adults with no history of long-term noise exposure. After adjusting for age and gender, relative to ISO 7029, the mean hearing threshold in the frequency range of 3 to 8 kHz was 6 dB in the musicians and 1.5 dB in the control group. This difference was statistically significant (Mann-Whitney rank sum test, p < 0.001). A significant difference was also observed between musicians using regular hearing protection during their activities (average 3 to 8 kHz thresholds = 2.4 dB) and musicians who never used such hearing protection (average 3 to 8 kHz thresholds = 8.2 dB), after adjusting for age and gender (Mann-Whitney rank sum test, p = 0.006). Eleven of the musicians (26%) were found to be hypersensitive to sound, and seven (17%) presented with tinnitus. Tinnitus assessment, however, did not reveal any clinically significant psychological distress in these individuals. Tinnitus and hypersensitivity to sound were observed in a significant minority within a group of nonprofessional pop/rock musicians who had experienced repeated exposure to intense sound levels over at least 5 yr but with minimal impact on their lives. Moreover, hearing loss was minimal in the subjects who always used ear protection, being only 0.9 dB higher than the control group. In contrast, hearing loss was significantly more pronounced, at 6.7 dB higher than the control group, in those musicians who never used ear protection. Continued education about the risk to hearing and the benefits of the persistent use of ear protection is warranted for musicians who are exposed frequently to intense sound levels.
Handbook of aircraft noise metrics
NASA Technical Reports Server (NTRS)
Bennett, R. L.; Pearsons, K. S.
1981-01-01
Information is presented on 22 noise metrics that are associated with the measurement and prediction of the effects of aircraft noise. Some of the instantaneous frequency weighted sound level measures, such as A-weighted sound level, are used to provide multiple assessment of the aircraft noise level. Other multiple event metrics, such as day-night average sound level, were designed to relate sound levels measured over a period of time to subjective responses in an effort to determine compatible land uses and aid in community planning. The various measures are divided into: (1) instantaneous sound level metrics; (2) duration corrected single event metrics; (3) multiple event metrics; and (4) speech communication metrics. The scope of each measure is examined in terms of its: definition, purpose, background, relationship to other measures, calculation method, example, equipment, references, and standards.
Handbook of aircraft noise metrics
NASA Astrophysics Data System (ADS)
Bennett, R. L.; Pearsons, K. S.
1981-03-01
Information is presented on 22 noise metrics that are associated with the measurement and prediction of the effects of aircraft noise. Some of the instantaneous frequency weighted sound level measures, such as A-weighted sound level, are used to provide multiple assessment of the aircraft noise level. Other multiple event metrics, such as day-night average sound level, were designed to relate sound levels measured over a period of time to subjective responses in an effort to determine compatible land uses and aid in community planning. The various measures are divided into: (1) instantaneous sound level metrics; (2) duration corrected single event metrics; (3) multiple event metrics; and (4) speech communication metrics. The scope of each measure is examined in terms of its: definition, purpose, background, relationship to other measures, calculation method, example, equipment, references, and standards.
Absolute auditory threshold: testing the absolute.
Heil, Peter; Matysiak, Artur
2017-11-02
The mechanisms underlying the detection of sounds in quiet, one of the simplest tasks for auditory systems, are debated. Several models proposed to explain the threshold for sounds in quiet and its dependence on sound parameters include a minimum sound intensity ('hard threshold'), below which sound has no effect on the ear. Also, many models are based on the assumption that threshold is mediated by integration of a neural response proportional to sound intensity. Here, we test these ideas. Using an adaptive forced choice procedure, we obtained thresholds of 95 normal-hearing human ears for 18 tones (3.125 kHz carrier) in quiet, each with a different temporal amplitude envelope. Grand-mean thresholds and standard deviations were well described by a probabilistic model according to which sensory events are generated by a Poisson point process with a low rate in the absence, and higher, time-varying rates in the presence, of stimulation. The subject actively evaluates the process and bases the decision on the number of events observed. The sound-driven rate of events is proportional to the temporal amplitude envelope of the bandpass-filtered sound raised to an exponent. We find no evidence for a hard threshold: When the model is extended to include such a threshold, the fit does not improve. Furthermore, we find an exponent of 3, consistent with our previous studies and further challenging models that are based on the assumption of the integration of a neural response that, at threshold sound levels, is directly proportional to sound amplitude or intensity. © 2017 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.
Noise exposure estimates of urban MP3 player users.
Levey, Sandra; Levey, Tania; Fligor, Brian J
2011-02-01
To examine the sound level and duration of use of personal listening devices (PLDs) by 189 college students, ages 18-53 years, as they entered a New York City college campus, to determine whether noise exposure from PLDs was in excess of recommended exposure limits and what factors might influence exposure. Free-field equivalent sound levels from PLD headphones were measured on a mannequin with a calibrated sound level meter. Participants reported demographic information, whether they had just come off the subway, the type of PLD and earphones used, and duration per day and days per week they used their PLDs. Based on measured free-field equivalent sound levels from PLD headphones and the reported PLD use, per day 58.2% of participants exceeded 85 dB A-weighted 8-hr equivalent sound levels (L(Aeq)), and per week 51.9% exceeded 85 dB A-weighted 40-hr equivalent continuous sound levels (L(Awkn)). The majority of PLD users exceeded recommended sound exposure limits, suggesting that they were at increased risk for noise-induced hearing loss. Analyses of the demographics of these participants and mode of transportation to campus failed to indicate any particular gender differences in PLD use or in mode of transportation influencing sound exposure.
NASA Astrophysics Data System (ADS)
Breitzke, Monika; Bohlen, Thomas
2010-05-01
Modelling sound propagation in the ocean is an essential tool to assess the potential risk of air-gun shots on marine mammals. Based on a 2.5-D finite-difference code a full waveform modelling approach is presented, which determines both sound exposure levels of single shots and cumulative sound exposure levels of multiple shots fired along a seismic line. Band-limited point source approximations of compact air-gun clusters deployed by R/V Polarstern in polar regions are used as sound sources. Marine mammals are simulated as static receivers. Applications to deep and shallow water models including constant and depth-dependent sound velocity profiles of the Southern Ocean show dipole-like directivities in case of single shots and tubular cumulative sound exposure level fields beneath the seismic line in case of multiple shots. Compared to a semi-infinite model an incorporation of seafloor reflections enhances the seismically induced noise levels close to the sea surface. Refraction due to sound velocity gradients and sound channelling in near-surface ducts are evident, but affect only low to moderate levels. Hence, exposure zone radii derived for different hearing thresholds are almost independent of the sound velocity structure. With decreasing thresholds radii increase according to a spherical 20 log10 r law in case of single shots and according to a cylindrical 10 log10 r law in case of multiple shots. A doubling of the shot interval diminishes the cumulative sound exposure levels by -3 dB and halves the radii. The ocean bottom properties only slightly affect the radii in shallow waters, if the normal incidence reflection coefficient exceeds 0.2.
Contralateral Dpoae Suppression in Humans at Very Low Sound Intensities
NASA Astrophysics Data System (ADS)
Janssen, T.; Gehr, D. D.; Kevanishvili, Z.
2003-02-01
Different functions are attributed to the olivo-cochlear bundle system (OCBS) such as protecting the ear from acoustic injury, improving signal detection in noise, and mediating selective attention. OCBS reflex strength can be evaluated, in animals as well as in humans, by measuring the degree of suppression of an ipsilateral DPOAE by a contralateral sound. The purpose of the study was to evaluate OCBS reflex strength depending on ipsilateral stimulus level, especially at threshold, by means of extrapolated DPOAE I/O-functions. Additionally, DPOAE was measured at near-to-threshold contralateral stimulus levels when using low-level ipsilateral stimulation for investigating possible enhancement of outer hair cell motion in the presence of low-level contralateral sound. The recording of the 2f1-f2 DPOAE in the presence or absence of contralateral sound was performed in normally hearing human subjects at f2 = 2 kHz. DPOAE I/O-functions were measured in a primary tone level range from L2 = 20 to L2 = 65 dB SPL (L1 = 0.4L2 + 39, f2/f1=1.2). Broad-band noise (BBN), narrow-band noise from 1720 to 2320 Hz (NBN), and pure tones (PT) at f2, 2f1-f2, geometric mean of f1 and f2, and 0.1oct + f2 were used for contralateral stimulation. The contralateral stimulus level (Ls) was decreased from 70 down to 10 dB SPL in 10 dB steps. DPOAE suppression was highest at the lowest primary tone level and was more pronounced for BBN and NBN than for pure tones, suggesting a more diffuse than a strong tonotopic organisation of the OCBS. The contralateral stimulus level at which significant DPOAE suppression occurred (p < 0.05) was different for the different stimuli being 20, 40, and 70 dB SPL for BBN, NBN, and pure-tone (f2), respectively. Significant DPOAE suppression to BBN and NBN occurred at Ls well below audiological middle-ear reflex threshold. DPOAE time course was different for Ls below and above middle-ear reflex threshold. Thus, middle-ear muscle contraction is suggested not to be involved in DPOAE suppression at low Ls. No enhancement of DPOAE could be found. The findings suggest the OCBS to be functioning in a more protective way than for improving signal detection in noise.
NASA Technical Reports Server (NTRS)
Rasbury, Jack; Bascal, Kira; Ownby, Matt; McCulley, Phyllis; Paul, Bonnie
2004-01-01
A traditional stethoscope is currently flown on the International Space Station (ISS). The background noise on the ISS is much higher than a normal exam room, and the literature shows that traditional stethoscopes are unable to function effectively in high noise environments. Digital stethoscopes provide amplification which improves the audibility in a quiet environment. This study is designed to determine if digital stethoscopes offer any advantage over traditional stethoscopes in being able to identify normal and abnormal sounds in the ISS noise environment. Methods: An ISS noise simulation facility was created to reproduce ISS noise profiles by modifying pink noise with a software-based graphic equalizer. The files were played in a continuous loop on a computer, amplified through a high-end stereo system and adjusted using a sound level meter. Nine caregiver analogues were given the same auscultation lesson received by astronauts. They began testing by becoming familiar with normal and abnormal sounds on a Student Auscultation Manikin . They then used two digital stethoscopes and a traditional stethoscope identical to the one flown on the ISS to auscultate the manikin sounds in the noise facility. They identified the sounds on a questionnaire and picked which of the three stethoscopes they preferred. Results: Evaluators displayed equivalent accuracy in sound identification when using either the 3M model 4000 digital stethoscope or traditional stethoscope. However, the 3M was preferred 2 to 1 by the evaluators, primarily because of additional amplification of the sounds. Discussion: Although our results show that the current ISS stethoscope and the "best-of-breed" digital stethoscope provide essentially the same auscultation utility, the latter has the advantage of recording and transmitting sounds to a remote physician. Since the astronaut caregivers are non-physiCians, this capability may be worth the additional expense and effort needed to certify the digital stethoscope for flight.
Design and evaluation of a parametric model for cardiac sounds.
Ibarra-Hernández, Roilhi F; Alonso-Arévalo, Miguel A; Cruz-Gutiérrez, Alejandro; Licona-Chávez, Ana L; Villarreal-Reyes, Salvador
2017-10-01
Heart sound analysis plays an important role in the auscultative diagnosis process to detect the presence of cardiovascular diseases. In this paper we propose a novel parametric heart sound model that accurately represents normal and pathological cardiac audio signals, also known as phonocardiograms (PCG). The proposed model considers that the PCG signal is formed by the sum of two parts: one of them is deterministic and the other one is stochastic. The first part contains most of the acoustic energy. This part is modeled by the Matching Pursuit (MP) algorithm, which performs an analysis-synthesis procedure to represent the PCG signal as a linear combination of elementary waveforms. The second part, also called residual, is obtained after subtracting the deterministic signal from the original heart sound recording and can be accurately represented as an autoregressive process using the Linear Predictive Coding (LPC) technique. We evaluate the proposed heart sound model by performing subjective and objective tests using signals corresponding to different pathological cardiac sounds. The results of the objective evaluation show an average Percentage of Root-Mean-Square Difference of approximately 5% between the original heart sound and the reconstructed signal. For the subjective test we conducted a formal methodology for perceptual evaluation of audio quality with the assistance of medical experts. Statistical results of the subjective evaluation show that our model provides a highly accurate approximation of real heart sound signals. We are not aware of any previous heart sound model rigorously evaluated as our proposal. Copyright © 2017 Elsevier Ltd. All rights reserved.
The sound exposure of the audience at a music festival.
Mercier, V; Luy, D; Hohmann, B W
2003-01-01
During the Paleo Festival in Nyon, Switzerland, which took place from 24th to 29th July 2001, ten volunteers were equipped each evening with small sound level meters which continuously monitored their sound exposure as they circulated among the various festival events. Sound levels at the mixing console and at the place where people are most heavily exposed (in front of the speakers) were measured simultaneously. In addition, a sample of 601 people from the audience were interviewed over the six days of the festival and asked their opinion of sound level and quality, as well as provide details of where in the arena they preferred to listen to the concerts, whether they used ear plugs, if they had experienced any tinnitus, and if so how long it had persisted. The individual sound exposure during a typical evening was on average 95 dB(A) although 8% of the volunteers were exposed to sound levels higher then 100 dB(A). Only 5% of the audience wore ear plugs throughout the concert while 34% used them occasionally. While some 36% of the people interviewed reported that they had experienced tinnitus after listening to loud music, the majority found both the music quality and the sound level good. The sound level limit of 100 dB(A) at the place where the people are most heavily exposed seems to be a good compromise between the public heath issue, the demands of artists and organisers, and the expectations of the public. However, considering the average sound levels to which the public are exposed during a single evening, it is recommended that ear plugs be used by concert-goers who attend more than one day of the festival.
[Reading ability of junior high school students in relation to self-evaluation and depression].
Yamashita, Toshiya; Hayashi, Takashi
2012-01-01
Guidelines for the diagnosis of reading disorders in elementary school students were published recently in Japan. On the basis of these guidelines, we administrated reading test batteries to 43 Japanese junior high-school students from grade two. The reading test consisted of single sounds, single words, and single sentences. We evaluated the reading speed and the number of reading errors made by the test takers; their performance was compared with the normal value for elementary school students in grade six, as stated in the guidelines. The reading ability of the junior high-school students was not higher than that of the elementary school students. Seven students (16.3%) were found to have reading difficulties (RD group) and they met the criterion for diagnosis of reading disorder as per the guidelines. Three students had difficulties in reading single sounds and single words, but they faced no problems when reading single sentences. It was supposed that the strategies used by the students for reading sentences may have differed from those used for reading single sounds or single words. No significant differences were found between the RD and non-RD group students on scores of scholastic self-evaluation, self-esteem, and depressive symptoms. Therefore, reading difficulty did not directly influence the level of self-evaluation or depression.
Applications of cluster analysis to satellite soundings
NASA Technical Reports Server (NTRS)
Munteanu, M. J.; Jakubowicz, O.; Kalnay, E.; Piraino, P.
1984-01-01
The advantages of the use of cluster analysis in the improvement of satellite temperature retrievals were evaluated since the use of natural clusters, which are associated with atmospheric temperature soundings characteristic of different types of air masses, has the potential for improving stratified regression schemes in comparison with currently used methods which stratify soundings based on latitude, season, and land/ocean. The method of discriminatory analysis was used. The correct cluster of temperature profiles from satellite measurements was located in 85% of the cases. Considerable improvement was observed at all mandatory levels using regression retrievals derived in the clusters of temperature (weighted and nonweighted) in comparison with the control experiment and with the regression retrievals derived in the clusters of brightness temperatures of 3 MSU and 5 IR channels.
Wind turbines and health: a critical review of the scientific literature.
McCunney, Robert J; Mundt, Kenneth A; Colby, W David; Dobie, Robert; Kaliski, Kenneth; Blais, Mark
2014-11-01
This review examines the literature related to health effects of wind turbines. We reviewed literature related to sound measurements near turbines, epidemiological and experimental studies, and factors associated with annoyance. (1) Infrasound sound near wind turbines does not exceed audibility thresholds. (2) Epidemiological studies have shown associations between living near wind turbines and annoyance. (3) Infrasound and low-frequency sound do not present unique health risks. (4) Annoyance seems more strongly related to individual characteristics than noise from turbines. Further areas of inquiry include enhanced noise characterization, analysis of predicted noise values contrasted with measured levels postinstallation, longitudinal assessments of health pre- and postinstallation, experimental studies in which subjects are "blinded" to the presence or absence of infrasound, and enhanced measurement techniques to evaluate annoyance.
Mooney, T Aran; Samson, Julia E; Schlunk, Andrea D; Zacarias, Samantha
2016-07-01
Sound is an abundant cue in the marine environment, yet we know little regarding the frequency range and levels which induce behavioral responses in ecologically key marine invertebrates. Here we address the range of sounds that elicit unconditioned behavioral responses in squid Doryteuthis pealeii, the types of responses generated, and how responses change over multiple sound exposures. A variety of response types were evoked, from inking and jetting to body pattern changes and fin movements. Squid responded to sounds from 80 to 1000 Hz, with response rates diminishing at the higher and lower ends of this frequency range. Animals responded to the lowest sound levels in the 200-400 Hz range. Inking, an escape response, was confined to the lower frequencies and highest sound levels; jetting was more widespread. Response latencies were variable but typically occurred after 0.36 s (mean) for jetting and 0.14 s for body pattern changes; pattern changes occurred significantly faster. These results demonstrate that squid can exhibit a range of behavioral responses to sound include fleeing, deimatic and protean behaviors, all of which are associated with predator evasion. Response types were frequency and sound level dependent, reflecting a relative loudness concept to sound perception in squid.
Schouten, Ben; Troje, Nikolaus F.; Vroomen, Jean; Verfaillie, Karl
2011-01-01
Background The focus in the research on biological motion perception traditionally has been restricted to the visual modality. Recent neurophysiological and behavioural evidence, however, supports the idea that actions are not represented merely visually but rather audiovisually. The goal of the present study was to test whether the perceived in-depth orientation of depth-ambiguous point-light walkers (plws) is affected by the presentation of looming or receding sounds synchronized with the footsteps. Methodology/Principal Findings In Experiment 1 orthographic frontal/back projections of plws were presented either without sound or with sounds of which the intensity level was rising (looming), falling (receding) or stationary. Despite instructions to ignore the sounds and to only report the visually perceived in-depth orientation, plws accompanied with looming sounds were more often judged to be facing the viewer whereas plws paired with receding sounds were more often judged to be facing away from the viewer. To test whether the effects observed in Experiment 1 act at a perceptual level rather than at the decisional level, in Experiment 2 observers perceptually compared orthographic plws without sound or paired with either looming or receding sounds to plws without sound but with perspective cues making them objectively either facing towards or facing away from the viewer. Judging whether either an orthographic plw or a plw with looming (receding) perspective cues is visually most looming becomes harder (easier) when the orthographic plw is paired with looming sounds. Conclusions/Significance The present results suggest that looming and receding sounds alter the judgements of the in-depth orientation of depth-ambiguous point-light walkers. While looming sounds are demonstrated to act at a perceptual level and make plws look more looming, it remains a challenge for future research to clarify at what level in the processing hierarchy receding sounds affect how observers judge the in-depth perception of plws. PMID:21373181
Evaluation of the noise exposure of symphonic orchestra musicians.
Rodrigues, Matilde Alexandra; Freitas, Marisa Alexandra; Neves, Maria Paula; Silva, Manuela Vieira
2014-01-01
For musicians, the impact of noise exposure is not yet fully characterized. Some inconsistencies can be found in the methodology used to evaluate noise exposure. This study aims to analyze the noise exposure of musicians in a symphonic orchestra to understand their risk for hearing loss, applying the methodology proposed by ISO 9612:2009. Noise levels were monitored among musicians during the rehearsal of eight different repertoires. Test subjects were selected according to their instrument and position in the orchestra. Participants wore noise dosimeters throughout the rehearsals. A sound meter was used to analyze the exposure of the conductor. The results showed that musicians are exposed to high noise levels that can damage hearing. Brass, woodwind and percussion and timpani musicians were exposed to noise levels in excess of the upper exposure action level of 85 dB (A), while the other instrumental groups had a lower exposure action level of 80 dB (A). Percussion musicians were exposed to high peak noise levels of 135 dB (C). Sound levels varied by instrument, repertoire and position. Octave frequency analyses showed differences among musicians. This study suggests that musicians are at risk for hearing loss. There is a need for more effective guidelines applicable to all countries, which should define standardized procedures for determining musician noise exposure and should allow exposure level normalization to the year, including different repertoires.
Measurements of humpback whale song sound levels received by a calf in association with a singer.
Chen, Jessica; Pack, Adam A; Au, Whitlow W L; Stimpert, Alison K
2016-11-01
Male humpback whales produce loud "songs" on the wintering grounds and some sing while escorting mother-calf pairs, exposing them to near-continuous sounds at close proximity. An Acousonde acoustic and movement recording tag deployed on a calf off Maui, Hawaii captured sounds produced by a singing male escort. Root-mean-square received levels ranged from 126 to 158 dB re 1 μPa. These levels represent rare direct measurements of sound to which a newly born humpback calf may be naturally exposed by a conspecific, and may provide a basis for informed decisions regarding anthropogenic sound levels projected near calves.
Aging Affects Adaptation to Sound-Level Statistics in Human Auditory Cortex.
Herrmann, Björn; Maess, Burkhard; Johnsrude, Ingrid S
2018-02-21
Optimal perception requires efficient and adaptive neural processing of sensory input. Neurons in nonhuman mammals adapt to the statistical properties of acoustic feature distributions such that they become sensitive to sounds that are most likely to occur in the environment. However, whether human auditory responses adapt to stimulus statistical distributions and how aging affects adaptation to stimulus statistics is unknown. We used MEG to study how exposure to different distributions of sound levels affects adaptation in auditory cortex of younger (mean: 25 years; n = 19) and older (mean: 64 years; n = 20) adults (male and female). Participants passively listened to two sound-level distributions with different modes (either 15 or 45 dB sensation level). In a control block with long interstimulus intervals, allowing neural populations to recover from adaptation, neural response magnitudes were similar between younger and older adults. Critically, both age groups demonstrated adaptation to sound-level stimulus statistics, but adaptation was altered for older compared with younger people: in the older group, neural responses continued to be sensitive to sound level under conditions in which responses were fully adapted in the younger group. The lack of full adaptation to the statistics of the sensory environment may be a physiological mechanism underlying the known difficulty that older adults have with filtering out irrelevant sensory information. SIGNIFICANCE STATEMENT Behavior requires efficient processing of acoustic stimulation. Animal work suggests that neurons accomplish efficient processing by adjusting their response sensitivity depending on statistical properties of the acoustic environment. Little is known about the extent to which this adaptation to stimulus statistics generalizes to humans, particularly to older humans. We used MEG to investigate how aging influences adaptation to sound-level statistics. Listeners were presented with sounds drawn from sound-level distributions with different modes (15 vs 45 dB). Auditory cortex neurons adapted to sound-level statistics in younger and older adults, but adaptation was incomplete in older people. The data suggest that the aging auditory system does not fully capitalize on the statistics available in sound environments to tune the perceptual system dynamically. Copyright © 2018 the authors 0270-6474/18/381989-11$15.00/0.
The hearing threshold of a harbor porpoise (Phocoena phocoena) for impulsive sounds (L).
Kastelein, Ronald A; Gransier, Robin; Hoek, Lean; de Jong, Christ A F
2012-08-01
The distance at which harbor porpoises can hear underwater detonation sounds is unknown, but depends, among other factors, on the hearing threshold of the species for impulsive sounds. Therefore, the underwater hearing threshold of a young harbor porpoise for an impulsive sound, designed to mimic a detonation pulse, was quantified by using a psychophysical technique. The synthetic exponential pulse with a 5 ms time constant was produced and transmitted by an underwater projector in a pool. The resulting underwater sound, though modified by the response of the projection system and by the pool, exhibited the characteristic features of detonation sounds: A zero to peak sound pressure level of at least 30 dB (re 1 s(-1)) higher than the sound exposure level, and a short duration (34 ms). The animal's 50% detection threshold for this impulsive sound occurred at a received unweighted broadband sound exposure level of 60 dB re 1 μPa(2)s. It is shown that the porpoise's audiogram for short-duration tonal signals [Kastelein et al., J. Acoust. Soc. Am. 128, 3211-3222 (2010)] can be used to estimate its hearing threshold for impulsive sounds.
Model-based synthesis of aircraft noise to quantify human perception of sound quality and annoyance
NASA Astrophysics Data System (ADS)
Berckmans, D.; Janssens, K.; Van der Auweraer, H.; Sas, P.; Desmet, W.
2008-04-01
This paper presents a method to synthesize aircraft noise as perceived on the ground. The developed method gives designers the opportunity to make a quick and economic evaluation concerning sound quality of different design alternatives or improvements on existing aircraft. By presenting several synthesized sounds to a jury, it is possible to evaluate the quality of different aircraft sounds and to construct a sound that can serve as a target for future aircraft designs. The combination of using a sound synthesis method that can perform changes to a recorded aircraft sound together with executing jury tests allows to quantify the human perception of aircraft noise.
Bottalico, Pasquale; Graetzer, Simone; Hunter, Eric J.
2015-01-01
Speakers adjust their vocal effort when communicating in different room acoustic and noise conditions and when instructed to speak at different volumes. The present paper reports on the effects of voice style, noise level, and acoustic feedback on vocal effort, evaluated as sound pressure level, and self-reported vocal fatigue, comfort, and control. Speakers increased their level in the presence of babble and when instructed to talk in a loud style, and lowered it when acoustic feedback was increased and when talking in a soft style. Self-reported responses indicated a preference for the normal style without babble noise. PMID:26723357
NASA Technical Reports Server (NTRS)
Costanza, Bryan T.; Horne, William C.; Schery, S. D.; Babb, Alex T.
2011-01-01
The Aero-Physics Branch at NASA Ames Research Center utilizes a 32- by 48-inch subsonic wind tunnel for aerodynamics research. The feasibility of acquiring acoustic measurements with a phased microphone array was recently explored. Acoustic characterization of the wind tunnel was carried out with a floor-mounted 24-element array and two ceiling-mounted speakers. The minimum speaker level for accurate level measurement was evaluated for various tunnel speeds up to a Mach number of 0.15 and streamwise speaker locations. A variety of post-processing procedures, including conventional beamforming and deconvolutional processing such as TIDY, were used. The speaker measurements, with and without flow, were used to compare actual versus simulated in-flow speaker calibrations. Data for wind-off speaker sound and wind-on tunnel background noise were found valuable for predicting sound levels for which the speakers were detectable when the wind was on. Speaker sources were detectable 2 - 10 dB below the peak background noise level with conventional data processing. The effectiveness of background noise cross-spectral matrix subtraction was assessed and found to improve the detectability of test sound sources by approximately 10 dB over a wide frequency range.
NASA Astrophysics Data System (ADS)
Gauthier, P.-A.; Camier, C.; Lebel, F.-A.; Pasco, Y.; Berry, A.; Langlois, J.; Verron, C.; Guastavino, C.
2016-08-01
Sound environment reproduction of various flight conditions in aircraft mock-ups is a valuable tool for the study, prediction, demonstration and jury testing of interior aircraft sound quality and annoyance. To provide a faithful reproduced sound environment, time, frequency and spatial characteristics should be preserved. Physical sound field reproduction methods for spatial sound reproduction are mandatory to immerse the listener's body in the proper sound fields so that localization cues are recreated at the listener's ears. Vehicle mock-ups pose specific problems for sound field reproduction. Confined spaces, needs for invisible sound sources and very specific acoustical environment make the use of open-loop sound field reproduction technologies such as wave field synthesis (based on free-field models of monopole sources) not ideal. In this paper, experiments in an aircraft mock-up with multichannel least-square methods and equalization are reported. The novelty is the actual implementation of sound field reproduction with 3180 transfer paths and trim panel reproduction sources in laboratory conditions with a synthetic target sound field. The paper presents objective evaluations of reproduced sound fields using various metrics as well as sound field extrapolation and sound field characterization.
14 CFR 36.6 - Incorporation by reference.
Code of Federal Regulations, 2010 CFR
2010-01-01
... No. 179, entitled “Precision Sound Level Meters,” dated 1973. (ii) IEC Publication No. 225, entitled... 1966. (iii) IEC Publication No. 651, entitled “Sound Level Meters,” first edition, dated 1979. (iv) IEC... edition, dated 1976. (v) IEC Publication No. 804, entitled “Integrating-averaging Sound Level Meters...
49 CFR 210.25 - Measurement criteria and procedures.
Code of Federal Regulations, 2011 CFR
2011-10-01
... American National Standard Institute Standards, “Method for Measurement of Sound Pressure Levels,” (ANSI S1... measurement indicating a violation. (ii) The sound level measurement system shall be checked not less than... calibrator of the microphone coupler type designed for the sound level measurement system in use shall be...
49 CFR 325.25 - Calibration of measurement systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Standard Institute Standard Methods for Measurements of Sound Pressure Levels (ANSI S1.13-1971) for field... sound level measurement system must be calibrated and appropriately adjusted at one or more frequencies... 5-15 minutes thereafter, until it has been determined that the sound level measurement system has...
49 CFR 325.25 - Calibration of measurement systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Standard Institute Standard Methods for Measurements of Sound Pressure Levels (ANSI S1.13-1971) for field... sound level measurement system must be calibrated and appropriately adjusted at one or more frequencies... 5-15 minutes thereafter, until it has been determined that the sound level measurement system has...
49 CFR 325.39 - Measurement procedure; highway operations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... shall be made of the sound level generated by a motor vehicle operating through the measurement area on..., acceleration or deceleration. (b) The sound level generated by the motor vehicle is the highest reading observed on the sound level measurement system as the vehicle passes through the measurement area...
49 CFR 325.39 - Measurement procedure; highway operations.
Code of Federal Regulations, 2011 CFR
2011-10-01
... shall be made of the sound level generated by a motor vehicle operating through the measurement area on..., acceleration or deceleration. (b) The sound level generated by the motor vehicle is the highest reading observed on the sound level measurement system as the vehicle passes through the measurement area...
24 CFR 51.103 - Criteria and standards.
Code of Federal Regulations, 2011 CFR
2011-04-01
...-night average sound level produced as the result of the accumulation of noise from all sources contributing to the external noise environment at the site. Day-night average sound level, abbreviated as DNL and symbolized as Ldn, is the 24-hour average sound level, in decibels, obtained after addition of 10...
Calculating far-field radiated sound pressure levels from NASTRAN output
NASA Technical Reports Server (NTRS)
Lipman, R. R.
1986-01-01
FAFRAP is a computer program which calculates far field radiated sound pressure levels from quantities computed by a NASTRAN direct frequency response analysis of an arbitrarily shaped structure. Fluid loading on the structure can be computed directly by NASTRAN or an added-mass approximation to fluid loading on the structure can be used. Output from FAFRAP includes tables of radiated sound pressure levels and several types of graphic output. FAFRAP results for monopole and dipole sources compare closely with an explicit calculation of the radiated sound pressure level for those sources.
NASA Technical Reports Server (NTRS)
Rentz, P. E.
1976-01-01
Experimental evaluations of the acoustical characteristics and source sound power and directionality measurement capabilities of the NASA Lewis 9 x 15 foot low speed wind tunnel in the untreated or hardwall configuration were performed. The results indicate that source sound power estimates can be made using only settling chamber sound pressure measurements. The accuracy of these estimates, expressed as one standard deviation, can be improved from + or - 4 db to + or - 1 db if sound pressure measurements in the preparation room and diffuser are also used and source directivity information is utilized. A simple procedure is presented. Acceptably accurate measurements of source direct field acoustic radiation were found to be limited by the test section reverberant characteristics to 3.0 feet for omni-directional and highly directional sources. Wind-on noise measurements in the test section, settling chamber and preparation room were found to depend on the sixth power of tunnel velocity. The levels were compared with various analytic models. Results are presented and discussed.
A statistical evaluation and comparison of VISSR Atmospheric Sounder (VAS) data
NASA Technical Reports Server (NTRS)
Jedlovec, G. J.
1984-01-01
In order to account for the temporal and spatial discrepancies between the VAS and rawinsonde soundings, the rawinsonde data were adjusted to a common hour of release where the new observation time corresponded to the satellite scan time. Both the satellite and rawinsonde observations of the basic atmospheric parameters (T Td, and Z) were objectively analyzed to a uniform grid maintaining the same mesoscale structure in each data set. The performance of each retrieval algorithm in producing accurate and representative soundings was evaluated using statistical parameters such as the mean, standard deviation, and root mean square of the difference fields for each parameter and grid level. Horizontal structure was also qualitatively evaluated by examining atmospheric features on constant pressure surfaces. An analysis of the vertical structure of the atmosphere were also performed by looking at colocated and grid mean vertical profiles of both the satellite and rawinsonde data sets. Highlights of these results are presented.
Evaluation of road traffic noise abatement by vegetation treatment in a 1:10 urban scale model.
Jang, Hyung Suk; Lee, Sung Chan; Jeon, Jin Yong; Kang, Jian
2015-12-01
A 1:10 scale of a street canyon and courtyard was constructed to evaluate sound propagation when various vegetation treatments including trees, shrubs, vegetated facades, and green roofs were installed in the urban environment. Noise reductions in the street canyon and courtyard were measured for both single and combined vegetation treatments. Vegetated facades mitigated the overall noise level up to 1.6 dBA in the street canyon, and greening facades were effective to reduce low frequency noise levels below 1 kHz. Trees increased the noise level at high frequency bands to some extent in the street canyon, while the noise level over 1 kHz decreased in the courtyard after installing the street trees. This is because tree crowns diffused and reflected high frequency sounds into the street canyon. Green roofs offered significant noise abatement over 1 kHz in the courtyard, while the vegetated facade was effective to reduce noise levels at low frequencies. In terms of the integrated effects of vegetation treatments, a combined vegetation treatment was less effective than the sum of single treatments in the street canyon. The maximum noise reduction observed for all combinations of vegetation treatments provided 3.4 dBA of insertion loss in the courtyard.
Swanepoel, De Wet; Matthysen, Cornelia; Eikelboom, Robert H; Clark, Jackie L; Hall, James W
2015-01-01
Accessibility of audiometry is hindered by the cost of sound booths and shortage of hearing health personnel. This study investigated the validity of an automated mobile diagnostic audiometer with increased attenuation and real-time noise monitoring for clinical testing outside a sound booth. Attenuation characteristics and reference ambient noise levels for the computer-based audiometer (KUDUwave) was evaluated alongside the validity of environmental noise monitoring. Clinical validity was determined by comparing air- and bone-conduction thresholds obtained inside and outside the sound booth (23 subjects). Twenty-three normal-hearing subjects (age range, 20-75 years; average age 35.5) and a sub group of 11 subjects to establish test-retest reliability. Improved passive attenuation and valid environmental noise monitoring was demonstrated. Clinically, air-conduction thresholds inside and outside the sound booth, corresponded within 5 dB or less > 90% of instances (mean absolute difference 3.3 ± 3.2 SD). Bone conduction thresholds corresponded within 5 dB or less in 80% of comparisons between test environments, with a mean absolute difference of 4.6 dB (3.7 SD). Threshold differences were not statistically significant. Mean absolute test-retest differences outside the sound booth was similar to those in the booth. Diagnostic pure-tone audiometry outside a sound booth, using automated testing, improved passive attenuation, and real-time environmental noise monitoring demonstrated reliable hearing assessments.
24 CFR Appendix I to Subpart B of... - Definition of Acoustical Quantities
Code of Federal Regulations, 2010 CFR
2010-04-01
... micropascals. Day-night average sound level, abbreviated as DNL, and symbolized mathematically as Ldn is... day-night average sound level produced by the loud impulsive sounds shall have 8 decibels added to it...
The acoustic performance of double-skin facades: A design support tool for architects
NASA Astrophysics Data System (ADS)
Batungbakal, Aireen
This study assesses and validates the influence of measuring sound in the urban environment and the influence of glass facade components in reducing sound transmission to the indoor environment. Among the most reported issues affecting workspaces, increased awareness to minimize noise led building designers to reconsider the design of building envelopes and its site environment. Outdoor sound conditions, such as traffic noise, challenge designers to accurately estimate the capability of glass facades in acquiring an appropriate indoor sound quality. Indicating the density of the urban environment, field-tests acquired existing sound levels in areas of high commercial development, employment, and traffic activity, establishing a baseline for sound levels common in urban work areas. Composed from the direct sound transmission loss of glass facades simulated through INSUL, a sound insulation software, data is utilized as an informative tool correlating the response of glass facade components towards existing outdoor sound levels of a project site in order to achieve desired indoor sound levels. This study progresses to link the disconnection in validating the acoustic performance of glass facades early in a project's design, from conditioned settings such as field-testing and simulations to project completion. Results obtained from the study's facade simulations and facade comparison supports that acoustic comfort is not limited to a singular solution, but multiple design options responsive to its environment.
Brief report: sound output of infant humidifiers.
Royer, Allison K; Wilson, Paul F; Royer, Mark C; Miyamoto, Richard T
2015-06-01
The sound pressure levels (SPLs) of common infant humidifiers were determined to identify the likely sound exposure to infants and young children. This primary investigative research study was completed at a tertiary-level academic medical center otolaryngology and audiology laboratory. Five commercially available humidifiers were obtained from brick-and-mortar infant supply stores. Sound levels were measured at 20-, 100-, and 150-cm distances at all available humidifier settings. Two of 5 (40%) humidifiers tested had SPL readings greater than the recommended hospital infant nursery levels (50 dB) at distances up to 100 cm. In this preliminary study, it was demonstrated that humidifiers marketed for infant nurseries may produce appreciably high decibel levels. Further characterization of the effect of humidifier design on SPLs and further elucidation of ambient sound levels associated with hearing risk are necessary before definitive conclusions and recommendations can be made. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.
Robust Feedback Control of Flow Induced Structural Radiation of Sound
NASA Technical Reports Server (NTRS)
Heatwole, Craig M.; Bernhard, Robert J.; Franchek, Matthew A.
1997-01-01
A significant component of the interior noise of aircraft and automobiles is a result of turbulent boundary layer excitation of the vehicular structure. In this work, active robust feedback control of the noise due to this non-predictable excitation is investigated. Both an analytical model and experimental investigations are used to determine the characteristics of the flow induced structural sound radiation problem. The problem is shown to be broadband in nature with large system uncertainties associated with the various operating conditions. Furthermore the delay associated with sound propagation is shown to restrict the use of microphone feedback. The state of the art control methodologies, IL synthesis and adaptive feedback control, are evaluated and shown to have limited success for solving this problem. A robust frequency domain controller design methodology is developed for the problem of sound radiated from turbulent flow driven plates. The control design methodology uses frequency domain sequential loop shaping techniques. System uncertainty, sound pressure level reduction performance, and actuator constraints are included in the design process. Using this design method, phase lag was added using non-minimum phase zeros such that the beneficial plant dynamics could be used. This general control approach has application to lightly damped vibration and sound radiation problems where there are high bandwidth control objectives requiring a low controller DC gain and controller order.
A critical review of the potential impacts of marine seismic surveys on fish & invertebrates.
Carroll, A G; Przeslawski, R; Duncan, A; Gunning, M; Bruce, B
2017-01-15
Marine seismic surveys produce high intensity, low-frequency impulsive sounds at regular intervals, with most sound produced between 10 and 300Hz. Offshore seismic surveys have long been considered to be disruptive to fisheries, but there are few ecological studies that target commercially important species, particularly invertebrates. This review aims to summarise scientific studies investigating the impacts of low-frequency sound on marine fish and invertebrates, as well as to critically evaluate how such studies may apply to field populations exposed to seismic operations. We focus on marine seismic surveys due to their associated unique sound properties (i.e. acute, low-frequency, mobile source locations), as well as fish and invertebrates due to the commercial value of many species in these groups. The main challenges of seismic impact research are the translation of laboratory results to field populations over a range of sound exposure scenarios and the lack of sound exposure standardisation which hinders the identification of response thresholds. An integrated multidisciplinary approach to manipulative and in situ studies is the most effective way to establish impact thresholds in the context of realistic exposure levels, but if that is not practical the limitations of each approach must be carefully considered. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.
Using listening difficulty ratings of conditions for speech communication in rooms
NASA Astrophysics Data System (ADS)
Sato, Hiroshi; Bradley, John S.; Morimoto, Masayuki
2005-03-01
The use of listening difficulty ratings of speech communication in rooms is explored because, in common situations, word recognition scores do not discriminate well among conditions that are near to acceptable. In particular, the benefits of early reflections of speech sounds on listening difficulty were investigated and compared to the known benefits to word intelligibility scores. Listening tests were used to assess word intelligibility and perceived listening difficulty of speech in simulated sound fields. The experiments were conducted in three types of sound fields with constant levels of ambient noise: only direct sound, direct sound with early reflections, and direct sound with early reflections and reverberation. The results demonstrate that (1) listening difficulty can better discriminate among these conditions than can word recognition scores; (2) added early reflections increase the effective signal-to-noise ratio equivalent to the added energy in the conditions without reverberation; (3) the benefit of early reflections on difficulty scores is greater than expected from the simple increase in early arriving speech energy with reverberation; (4) word intelligibility tests are most appropriate for conditions with signal-to-noise (S/N) ratios less than 0 dBA, and where S/N is between 0 and 15-dBA S/N, listening difficulty is a more appropriate evaluation tool. .
Ultrasound biofeedback treatment for persisting childhood apraxia of speech.
Preston, Jonathan L; Brick, Nickole; Landi, Nicole
2013-11-01
The purpose of this study was to evaluate the efficacy of a treatment program that includes ultrasound biofeedback for children with persisting speech sound errors associated with childhood apraxia of speech (CAS). Six children ages 9-15 years participated in a multiple baseline experiment for 18 treatment sessions during which treatment focused on producing sequences involving lingual sounds. Children were cued to modify their tongue movements using visual feedback from real-time ultrasound images. Probe data were collected before, during, and after treatment to assess word-level accuracy for treated and untreated sound sequences. As participants reached preestablished performance criteria, new sequences were introduced into treatment. All participants met the performance criterion (80% accuracy for 2 consecutive sessions) on at least 2 treated sound sequences. Across the 6 participants, performance criterion was met for 23 of 31 treated sequences in an average of 5 sessions. Some participants showed no improvement in untreated sequences, whereas others showed generalization to untreated sequences that were phonetically similar to the treated sequences. Most gains were maintained 2 months after the end of treatment. The percentage of phonemes correct increased significantly from pretreatment to the 2-month follow-up. A treatment program including ultrasound biofeedback is a viable option for improving speech sound accuracy in children with persisting speech sound errors associated with CAS.
Disturbance caused by aircraft noise
NASA Technical Reports Server (NTRS)
Josse, R.
1980-01-01
Noise pollution caused by the presence of airfields adjacent to residential areas is studied. Noise effects on the sleep of residents near airports and the degree of the residents noise tolerance are evaluated. What aircraft noises are annoying and to what extent the annoyance varies with sound level are discussed.
49 CFR 325.79 - Application of correction factors.
Code of Federal Regulations, 2011 CFR
2011-10-01
... illustrate the application of correction factors to sound level measurement readings: (1) Example 1—Highway operations. Assume that a motor vehicle generates a maximum observed sound level reading of 86 dB(A) during a... of the test site is acoustically “hard.” The corrected sound level generated by the motor vehicle...
49 CFR 325.79 - Application of correction factors.
Code of Federal Regulations, 2010 CFR
2010-10-01
... illustrate the application of correction factors to sound level measurement readings: (1) Example 1—Highway operations. Assume that a motor vehicle generates a maximum observed sound level reading of 86 dB(A) during a... of the test site is acoustically “hard.” The corrected sound level generated by the motor vehicle...
The rotary subwoofer: a controllable infrasound source.
Park, Joseph; Garcés, Milton; Thigpen, Bruce
2009-04-01
The rotary subwoofer is a novel acoustic transducer capable of projecting infrasonic signals at high sound pressure levels. The projector produces higher acoustic particle velocities than conventional transducers which translate into higher radiated sound pressure levels. This paper characterizes measured performance of a rotary subwoofer and presents a model to predict sound pressure levels.
EEG oscillations entrain their phase to high-level features of speech sound.
Zoefel, Benedikt; VanRullen, Rufin
2016-01-01
Phase entrainment of neural oscillations, the brain's adjustment to rhythmic stimulation, is a central component in recent theories of speech comprehension: the alignment between brain oscillations and speech sound improves speech intelligibility. However, phase entrainment to everyday speech sound could also be explained by oscillations passively following the low-level periodicities (e.g., in sound amplitude and spectral content) of auditory stimulation-and not by an adjustment to the speech rhythm per se. Recently, using novel speech/noise mixture stimuli, we have shown that behavioral performance can entrain to speech sound even when high-level features (including phonetic information) are not accompanied by fluctuations in sound amplitude and spectral content. In the present study, we report that neural phase entrainment might underlie our behavioral findings. We observed phase-locking between electroencephalogram (EEG) and speech sound in response not only to original (unprocessed) speech but also to our constructed "high-level" speech/noise mixture stimuli. Phase entrainment to original speech and speech/noise sound did not differ in the degree of entrainment, but rather in the actual phase difference between EEG signal and sound. Phase entrainment was not abolished when speech/noise stimuli were presented in reverse (which disrupts semantic processing), indicating that acoustic (rather than linguistic) high-level features play a major role in the observed neural entrainment. Our results provide further evidence for phase entrainment as a potential mechanism underlying speech processing and segmentation, and for the involvement of high-level processes in the adjustment to the rhythm of speech. Copyright © 2015 Elsevier Inc. All rights reserved.
Jónsdottir, Valdis; Laukkanen, Anne-Maria; Siikki, Ilona
2003-01-01
The present study investigated changes in the voice quality of teachers during a working day (a). in ordinary conditions and (b). when using electrical sound amplification while teaching. Classroom speech of 5 teachers was recorded with a portable DAT recorder and a head-mounted microphone during the first and the last lesson of a hard working day first in ordinary conditions and the following week using amplification. Long-term average spectrum and sound pressure level (SPL) analyses were made. The subjects' comments were gathered by questionnaire. Voice quality was evaluated by 2 speech trainers. With amplification, SPL was lower and the spectrum more tilted. Voice quality was evaluated to be better. The subjects reported less fatigue in the vocal mechanism. Spectral tilt decreased and SPL increased during the day. There was a tendency for perceived asthenia to decrease. No significant changes were observed in ordinary conditions. The acoustic changes seem to reflect a positive adaptation to vocal loading. Their absence may be a sign of vocal fatigue. Copyright 2003 S. Karger AG, Basel
Physiological and Psychological Evaluation of Strength of Auditory Stimulus
NASA Astrophysics Data System (ADS)
Umehara, Susumu; Asano, Hirotoshi; Ide, Hideto
In this study, we evaluated the pleasantness or unpleasantness experienced by human beings depending on the intensity of sound; using the nasal skin temperature that was determined using thermograms obtained from an infrared thermograph. Many studies have been carried out on the influence of sound intensity on human beings. However, the effect of sound has not been evaluated on the basis of facial skin temperature. We evaluated the experienced with variations in changes in the pleasure or displeasure noise; this was evaluated on the basis of facial skin temperature, electroencephalogram, and heart rate variability. The experimental results showed that the effect of variations in the sound intensity on the changes in the pleasure or displeasure experienced by human beings can be quantitatively evaluated on the basis of facial skin temperature.
Evaluative Conditioning Induces Changes in Sound Valence
Bolders, Anna C.; Band, Guido P. H.; Stallen, Pieter Jan
2012-01-01
Through evaluative conditioning (EC) a stimulus can acquire an affective value by pairing it with another affective stimulus. While many sounds we encounter daily have acquired an affective value over life, EC has hardly been tested in the auditory domain. To get a more complete understanding of affective processing in auditory domain we examined EC of sound. In Experiment 1 we investigated whether the affective evaluation of short environmental sounds can be changed using affective words as unconditioned stimuli (US). Congruency effects on an affective priming task for conditioned sounds demonstrated successful EC. Subjective ratings for sounds paired with negative words changed accordingly. In Experiment 2 we investigated whether extinction occurs, i.e., whether the acquired valence remains stable after repeated presentation of the conditioned sound without the US. The acquired affective value remained present, albeit weaker, even after 40 extinction trials. These results provide clear evidence for EC effects in the auditory domain. We will argue that both associative as well as propositional processes are likely to underlie these effects. PMID:22514545
Decadal trends in Indian Ocean ambient sound.
Miksis-Olds, Jennifer L; Bradley, David L; Niu, Xiaoyue Maggie
2013-11-01
The increase of ocean noise documented in the North Pacific has sparked concern on whether the observed increases are a global or regional phenomenon. This work provides evidence of low frequency sound increases in the Indian Ocean. A decade (2002-2012) of recordings made off the island of Diego Garcia, UK in the Indian Ocean was parsed into time series according to frequency band and sound level. Quarterly sound level comparisons between the first and last years were also performed. The combination of time series and temporal comparison analyses over multiple measurement parameters produced results beyond those obtainable from a single parameter analysis. The ocean sound floor has increased over the past decade in the Indian Ocean. Increases were most prominent in recordings made south of Diego Garcia in the 85-105 Hz band. The highest sound level trends differed between the two sides of the island; the highest sound levels decreased in the north and increased in the south. Rate, direction, and magnitude of changes among the multiple parameters supported interpretation of source functions driving the trends. The observed sound floor increases are consistent with concurrent increases in shipping, wind speed, wave height, and blue whale abundance in the Indian Ocean.
Decreasing sound and vibration during ground transport of infants with very low birth weight.
Prehn, J; McEwen, I; Jeffries, L; Jones, M; Daniels, T; Goshorn, E; Marx, C
2015-02-01
To measure the effectiveness of modifications to reduce sound and vibration during interhospital ground transport of a simulated infant with very low birth weight (VLBW) and a gestational age of 30 weeks, a period of high susceptibility to germinal matrix and intraventricular hemorrhage. Researchers measured vibration and sound levels during infant transport, and compared levels after modifications to the transport incubator mattresses, addition of vibration isolators under incubator wheels, addition of mass to the incubator mattress and addition of incubator acoustic cover. Modifications did not decrease sound levels inside the transport incubator during transport. The combination of a gel mattress over an air chambered mattress was effective in decreasing vibration levels for the 1368 g simulated infant. Transport mattress effectiveness in decreasing vibration is influenced by infant weight. Modifications that decrease vibration for infants weighing 2000 g are not effective for infants with VLBW. Sound levels are not affected by incubator covers, suggesting that sound is transmitted into the incubator as a low-frequency vibration through the incubator's contact with the ambulance. Medical transportation can apply industrial methods of vibration and sound control to protect infants with VLBW from excessive physical strain of transport during vulnerable periods of development.
Noise Levels in Patient Rooms and at Nursing Stations at Three VA Medical Centers.
Hill, Jennifer N; LaVela, Sherri L
2015-01-01
To conduct an assessment of sound, dB(A) levels, in two areas of the hospital: patient rooms and nurse stations using sound meters (SMs). The World Health Organization (WHO) recommends sound levels of 35 dB(A) during the day and 30 dB(A) during the night; however, many hospitals exceed these recommended levels. Assessing post-occupancy sound levels enables hospital administrators and healthcare workers to identify whether interventions to improve sound levels are needed. Sound assessments were conducted at three healthcare facilities in both patient rooms and nursing stations, and we include information on facility characteristics. An Amprobe SM-20A Sound Level Meter was placed for a 24-hr period and recorded decibel levels every 8 min. These sound levels were averaged for each hour for reporting purposes. Averages as well as highest and lowest readings are reported for both daytime (8 a.m.-10 p.m.) and nighttime (10 p.m.-8 a.m.) for each facility. All three sites are considered urban and are classified with the highest complexity level (1a). Average daytime measurements for patient rooms and their corresponding nurses stations were as follows: Site A-63 dB(A)/56 dB(A), Site B-52 dB(A)/55 dB(A), and Site C-42 dB(A)/59 dB(A). Average nighttime measurements for patient rooms and nurses stations were Site A-62 dB(A)/55 dB(A), Site B-48 dB(A)/55 dB(A), and Site C-42 dB(A)/60 dB(A). Our findings, considered independently and collectively, showed that facilities in this study exceeded the WHO-recommended sound levels for patient rooms of 35 dB(A) during daytime and 30 dB(A) during nighttime. Research has reported negative patient outcomes, for example, decreased satisfaction, sleep disturbance, and higher incidence of rehospitalization in patients staying in areas with higher noise levels. © The Author(s) 2015.
Tutorial and Guidelines on Measurement of Sound Pressure Level in Voice and Speech.
Švec, Jan G; Granqvist, Svante
2018-03-15
Sound pressure level (SPL) measurement of voice and speech is often considered a trivial matter, but the measured levels are often reported incorrectly or incompletely, making them difficult to compare among various studies. This article aims at explaining the fundamental principles behind these measurements and providing guidelines to improve their accuracy and reproducibility. Basic information is put together from standards, technical, voice and speech literature, and practical experience of the authors and is explained for nontechnical readers. Variation of SPL with distance, sound level meters and their accuracy, frequency and time weightings, and background noise topics are reviewed. Several calibration procedures for SPL measurements are described for stand-mounted and head-mounted microphones. SPL of voice and speech should be reported together with the mouth-to-microphone distance so that the levels can be related to vocal power. Sound level measurement settings (i.e., frequency weighting and time weighting/averaging) should always be specified. Classified sound level meters should be used to assure measurement accuracy. Head-mounted microphones placed at the proximity of the mouth improve signal-to-noise ratio and can be taken advantage of for voice SPL measurements when calibrated. Background noise levels should be reported besides the sound levels of voice and speech.
Amplitude modulation of sound from wind turbines under various meteorological conditions.
Larsson, Conny; Öhlund, Olof
2014-01-01
Wind turbine (WT) sound annoys some people even though the sound levels are relatively low. This could be because of the amplitude modulated "swishing" characteristic of the turbine sound, which is not taken into account by standard procedures for measuring average sound levels. Studies of sound immission from WTs were conducted continually between 19 August 2011 and 19 August 2012 at two sites in Sweden. A method for quantifying the degree and strength of amplitude modulation (AM) is introduced here. The method reveals that AM at the immission points occur under specific meteorological conditions. For WT sound immission, the wind direction and sound speed gradient are crucial for the occurrence of AM. Interference between two or more WTs could probably enhance AM. The mechanisms by which WT sound is amplitude modulated are not fully understood.
Relations among pure-tone sound stimuli, neural activity, and the loudness sensation
NASA Technical Reports Server (NTRS)
Howes, W. L.
1972-01-01
Both the physiological and psychological responses to pure-tone sound stimuli are used to derive formulas which: (1) relate the loudness, loudness level, and sound-pressure level of pure tones; (2) apply continuously over most of the acoustic regime, including the loudness threshold; and (3) contain no undetermined coefficients. Some of the formulas are fundamental for calculating the loudness of any sound. Power-law formulas relating the pure-tone sound stimulus, neural activity, and loudness are derived from published data.
Performance of an open-source heart sound segmentation algorithm on eight independent databases.
Liu, Chengyu; Springer, David; Clifford, Gari D
2017-08-01
Heart sound segmentation is a prerequisite step for the automatic analysis of heart sound signals, facilitating the subsequent identification and classification of pathological events. Recently, hidden Markov model-based algorithms have received increased interest due to their robustness in processing noisy recordings. In this study we aim to evaluate the performance of the recently published logistic regression based hidden semi-Markov model (HSMM) heart sound segmentation method, by using a wider variety of independently acquired data of varying quality. Firstly, we constructed a systematic evaluation scheme based on a new collection of heart sound databases, which we assembled for the PhysioNet/CinC Challenge 2016. This collection includes a total of more than 120 000 s of heart sounds recorded from 1297 subjects (including both healthy subjects and cardiovascular patients) and comprises eight independent heart sound databases sourced from multiple independent research groups around the world. Then, the HSMM-based segmentation method was evaluated using the assembled eight databases. The common evaluation metrics of sensitivity, specificity, accuracy, as well as the [Formula: see text] measure were used. In addition, the effect of varying the tolerance window for determining a correct segmentation was evaluated. The results confirm the high accuracy of the HSMM-based algorithm on a separate test dataset comprised of 102 306 heart sounds. An average [Formula: see text] score of 98.5% for segmenting S1 and systole intervals and 97.2% for segmenting S2 and diastole intervals were observed. The [Formula: see text] score was shown to increases with an increases in the tolerance window size, as expected. The high segmentation accuracy of the HSMM-based algorithm on a large database confirmed the algorithm's effectiveness. The described evaluation framework, combined with the largest collection of open access heart sound data, provides essential resources for evaluators who need to test their algorithms with realistic data and share reproducible results.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crecelius, E.A.; Fortman, T.J.; Kiesser, S.L.
1989-07-01
Concentrations of Cu, Pb, Zn, PAH's, TBT and FC bacteria were measured in surface sediment, sediment-trap, and water-column samples at two marinas in Puget Sound during summer of 1988. Levels of contaminants inside the marinas were compared with levels outside. TBT had greatest elevation in marina sediments compared to reference sediments. Few of sediments exceeded Puget Sound AET sediment quality values but most did exceed PSDDA screening levels for in-water disposal of dredged sediment. All marinas estimated to contribute less than one percent of total mass loading of Cu, Pb and Zn to main basin of Puget Sound. Contribution ofmore » TBT may be much more significant if antifouling paints are the major source for Puget Sound.« less
NASA Technical Reports Server (NTRS)
Lucas, Michael J.; Marcolini, Michael A.
1997-01-01
The Rotorcraft Noise Model (RNM) is an aircraft noise impact modeling computer program being developed for NASA-Langley Research Center which calculates sound levels at receiver positions either on a uniform grid or at specific defined locations. The basic computational model calculates a variety of metria. Acoustic properties of the noise source are defined by two sets of sound pressure hemispheres, each hemisphere being centered on a noise source of the aircraft. One set of sound hemispheres provides the broadband data in the form of one-third octave band sound levels. The other set of sound hemispheres provides narrowband data in the form of pure-tone sound pressure levels and phase. Noise contours on the ground are output graphically or in tabular format, and are suitable for inclusion in Environmental Impact Statements or Environmental Assessments.
Gokdogan, Ozan; Gokdogan, Cagil
2016-01-01
Objective: The aim of this article is to determine the level of noise in nurseries and pre-schools and also to compare measured levels with standard levels and evaluate the teachers’ level of annoyance. Materials and Methods: The level of noise was measured in three different schools. A total of 162 students, whose ages were between 3 and 6 years, and 12 teachers were included the study. Every age groups’ level of noise was measured during sleeping, gaming, and eating activity. In addition, teachers’ annoyance was assessed in different age groups. Results: The 4- to 6-year-old groups were found to have higher level of sounds than 3-year-old group. Eating period was found to be the highest level of sound whereas sleeping was found the lowest. Furthermore, teachers’ annoyance was found higher as the age decreased. Conclusion: Nurseries and pre-schools have noisy environment both for the students and the teachers. High level of noise, which has bad effects on health, is a public health problem. Both the students’ families and teachers must be aware of this annoying situation. PMID:27762254
Code of Federal Regulations, 2010 CFR
2010-07-01
... maximum A-weighted sound levels (FAST) for every retarder sound observed during the measurement period... performance as appropriate. (2) Data. The maximum A-weighted sound levels (FAST) for every car coupling impact...
Sulter, A M; Schutte, H K; Miller, D G
1996-06-01
To determine the influence of the factors gender, vocal training, sound intensity, pitch, and aging on vocal function, videolaryngostroboscopic images of 214 subjects, subdivided according to gender and status of vocal training, were evaluated by three judges with standardized rating scales, comprising aspects of laryngeal appearance (larynx/pharynx ratio; epiglottal shape; asymmetry arytenoid region; compensatory adjustments; thickness, width, length, and elasticity of vocal folds) and glottal functioning (amplitudes of excursion; duration, percentage, and type of vocal fold closure; phase differences; location of glottal chink). The video registrations were made while the subjects performed a set of phonatory tasks, comprising the utterance of the vowel /i/ at three levels of both fundamental frequency and sound intensity. Analysis of the rating scales showed generally sufficient agreement among judges. With the exception of more frequently observed complete closure and lateral phase differences of vocal fold excursions in trained subjects, no further differences were established between untrained and trained subjects. With an alpha level of p = 0.005, men differed from women with respect to laryngeal appearance (larynx/pharynx ratio, compensatory adjustments, and the presence of omega and deviant-shaped epiglottises), and their vocal folds were rated thicker in the vertical dimension, smaller in the lateral dimension, longer, and more tense, with smaller amplitudes of excursion during vibration. Glottal closure in male subjects was rated more complete, but briefer in duration. Significant effects of the factors pitch, sound intensity, and age on vocal fold appearance and glottal functioning were ascertained. Awareness of the influence of these factors, as well as the factor gender, on the rated scales is essential for an adequate evaluation of laryngostroboscopic images.
Visual stimuli in intervention approaches for pre-schoolers diagnosed with phonological delay.
Pedro, Cassandra Ferreira; Lousada, Marisa; Hall, Andreia; Jesus, Luis M T
2018-04-01
The aim of this study was to develop and content validate specific speech and language intervention picture cards: The Letter-Sound (L&S) cards. The present study was also focused on assessing the influence of these cards on letter-sound correspondences and speech sound production. An expert panel of six speech and language therapists analysed and discussed the L&S cards based on several criteria previously established. A Speech and Language Therapist carried out a 6-week therapeutic intervention with a group of seven Portuguese phonologically delayed pre-schoolers aged 5;3 to 6;5. The modified Bland-Altman method revealed good agreement among evaluators, that is the majority of the values was between the agreement limits. Additional outcome measures were collected before and after the therapeutic intervention process. Results indicate that the L&S cards facilitate the acquisition of letter-sound correspondences. Regarding speech sound production, some improvements were also observed at word level. The L&S cards are therefore likely to give phonetic cues, which are crucial for the correct production of therapeutic targets. These visual cues seemed to have helped children with phonological delay develop the above-mentioned skills.
Psycho-Physiological Responses by Listening to Some Sounds from Our Daily Life
NASA Astrophysics Data System (ADS)
Sakamoto, H.; Hayashi, F.; Tsujikawa, M.; Sugiura, S.
1997-08-01
This study was made to clarify the relationship between mode of identification, mode of emotion and physiological response to noise. Twenty-six subjects, young females, listened to six different daily sounds for 150 s through head phones. The level of sound was 60-61LAcq. The pulse wave and blood pressure were observed, and pulse wave interval, wave height and maximum and minimum blood pressures were measured. Measurements were taken twice once 30 s before listening and again during the final 30 s of listening. The ratio of the latter value to the former value was used as the index for the evaluation of change. Immediately after the listening session, identification of the sound source and emotional response were surveyed via a questionnaire and the sounds were judged as related to comfort or discomfort. In the case of incorrect identification, physiological functions were not seen to change significantly. However, in the case of correct identification, maximum and minimum blood pressures were significantly increased form the pre-listening values. The physiological functions of the discomfort group did not change significantly. In the comfort group, wave height was decreased and blood pressure was significantly elevated.
24 CFR 51.106 - Implementation.
Code of Federal Regulations, 2011 CFR
2011-04-01
... data. HUD field staff shall make maximum use of noise data prepared by others when such data are... day-night average sound level data are not available may be evaluated from NEF or CNEL analyses using... LCdn. (4) Use of areawide acoustical data. HUD encourages the preparation and use of areawide...
Contrasting Decadal-Scale Changes in Elevation and Vegetation in Two Long Island Sound Salt Marshes
Northeastern US salt marshes face multiple co-stressors, including accelerating rates of relative sea level rise (RSLR), elevated nutrient inputs, and low sediment supplies. In order to evaluate how marsh surface elevations respond to such factors, we used surface elevation table...
Assessing Higher Level Learning: Developing Rubrics for Case Analysis
ERIC Educational Resources Information Center
Rochford, Linda; Borchert, Patricia S.
2011-01-01
Case study analyses allow students to demonstrate proficiency in executing authentic tasks in marketing and management, facilitating faculty evaluation of higher order learning outcomes. Effective and consistent assessment of case analyses depends in large part on the development of sound rubrics. The authors explored the process of rubric…
Sound Pressure Levels Measured in a University Concert Band: A Risk of Noise-Induced Hearing Loss?
ERIC Educational Resources Information Center
Holland, Nicholas V., III
2008-01-01
Researchers have reported public school band directors as experiencing noise-induced hearing loss. Little research has focused on collegiate band directors and university student musicians. The present study measures the sound pressure levels generated within a university concert band and compares sound levels with the criteria set by the…
49 CFR 325.59 - Measurement procedure; stationary test.
Code of Federal Regulations, 2011 CFR
2011-10-01
... made of the sound level generated by a stationary motor vehicle as follows: (a) Park the motor vehicle... open throttle. Return the engine's speed to idle. (e) Observe the maximum reading on the sound level... this section until the first two maximum sound level readings that are within 2 dB(A) of each other are...
49 CFR 210.31 - Operation standards (stationary locomotives at 30 meters).
Code of Federal Regulations, 2011 CFR
2011-10-01
... prescribed in paragraph (a)(2) of this section, the A-weighted sound level reading in decibels shall be... A-weighted sound level reading in decibels that is observed during the 30-second period of time... test; (3) Date of test; and (4) The A-weighted sound level reading in decibels obtained during the...
Possibilities of psychoacoustics to determine sound quality
NASA Astrophysics Data System (ADS)
Genuit, Klaus
For some years, acoustic engineers have increasingly become aware of the importance of analyzing and minimizing noise problems not only with regard to the A-weighted sound pressure level, but to design sound quality. It is relatively easy to determine the A-weighted SPL according to international standards. However, the objective evaluation to describe subjectively perceived sound quality - taking into account psychoacoustic parameters such as loudness, roughness, fluctuation strength, sharpness and so forth - is more difficult. On the one hand, the psychoacoustic measurement procedures which are known so far have yet not been standardized. On the other hand, they have only been tested in laboratories by means of listening tests in the free-field and one sound source and simple signals. Therefore, the results achieved cannot be transferred to complex sound situations with several spatially distributed sound sources without difficulty. Due to the directional hearing and selectivity of human hearing, individual sound events can be selected among many. Already in the late seventies a new binaural Artificial Head Measurement System was developed which met the requirements of the automobile industry in terms of measurement technology. The first industrial application of the Artificial Head Measurement System was in 1981. Since that time the system was further developed, particularly by the cooperation between HEAD acoustics and Mercedes-Benz. In addition to a calibratable Artificial Head Measurement System which is compatible with standard measurement technologies and has transfer characteristics comparable to human hearing, a Binaural Analysis System is now also available. This system permits the analysis of binaural signals regarding physical and psychoacoustic procedures. Moreover, the signals to be analyzed can be simultaneously monitored through headphones and manipulated in the time and frequency domain so that those signal components being responsible for noise annoyance can be found. Especially in complex sound situations with several spatially distributed sound sources, standard, one-channel measurements methods cannot adequately determine sound quality, the acoustic comfort, or annoyance of sound events.
Prevalence of Tinnitus and Noise-induced Hearing Loss in Dentists
Myers, Jamie; John, Andrew B.; Kimball, Suzanne; Fruits, Terry
2016-01-01
Introduction: The purpose of this study was to evaluate noise levels in dental offices and to estimate the risk and prevalence of tinnitus and noise-induced hearing loss (NIHL) in practicing dentists. Materials and Methods: First, measures were collected of sound pressure levels produced by dental handpieces and dental suction in the University of Oklahoma Health Sciences Center (OUHSC) College of Dentistry. Second, a survey was distributed to members of the Oklahoma Dental Association (ODA). Results: Measurements made in the dental operatory revealed dangerous levels when high-volume suction was in use alone and in conjunction with a dental handpiece. Questionnaire results suggested that practicing dentists report sensorineural hearing loss at a rate broadly in line with national averages. However, dentists reported a higher prevalence of tinnitus symptoms than would be expected based on sample demographics. Conclusion: Results from sound level measurements and questionnaire responses indicate that dentists are a population that could be placing their hearing health at risk in a typical daily work environment. PMID:27991466
Differences between Outdoor and Indoor Sound Levels for Open, Tilted, and Closed Windows
Locher, Barbara; Piquerez, André; Habermacher, Manuel; Ragettli, Martina; Cajochen, Christian; Vienneau, Danielle; Foraster, Maria; Müller, Uwe; Wunderli, Jean Marc
2018-01-01
Noise exposure prediction models for health effect studies normally estimate free field exposure levels outside. However, to assess the noise exposure inside dwellings, an estimate of indoor sound levels is necessary. To date, little field data is available about the difference between indoor and outdoor noise levels and factors affecting the damping of outside noise. This is a major cause of uncertainty in indoor noise exposure prediction and may lead to exposure misclassification in health assessments. This study aims to determine sound level differences between the indoors and the outdoors for different window positions and how this sound damping is related to building characteristics. For this purpose, measurements were carried out at home in a sample of 102 Swiss residents exposed to road traffic noise. Sound pressure level recordings were performed outdoors and indoors, in the living room and in the bedroom. Three scenarios—of open, tilted, and closed windows—were recorded for three minutes each. For each situation, data on additional parameters such as the orientation towards the source, floor, and room, as well as sound insulation characteristics were collected. On that basis, linear regression models were established. The median outdoor–indoor sound level differences were of 10 dB(A) for open, 16 dB(A) for tilted, and 28 dB(A) for closed windows. For open and tilted windows, the most relevant parameters affecting the outdoor–indoor differences were the position of the window, the type and volume of the room, and the age of the building. For closed windows, the relevant parameters were the sound level outside, the material of the window frame, the existence of window gaskets, and the number of windows. PMID:29346318
Differences between Outdoor and Indoor Sound Levels for Open, Tilted, and Closed Windows.
Locher, Barbara; Piquerez, André; Habermacher, Manuel; Ragettli, Martina; Röösli, Martin; Brink, Mark; Cajochen, Christian; Vienneau, Danielle; Foraster, Maria; Müller, Uwe; Wunderli, Jean Marc
2018-01-18
Noise exposure prediction models for health effect studies normally estimate free field exposure levels outside. However, to assess the noise exposure inside dwellings, an estimate of indoor sound levels is necessary. To date, little field data is available about the difference between indoor and outdoor noise levels and factors affecting the damping of outside noise. This is a major cause of uncertainty in indoor noise exposure prediction and may lead to exposure misclassification in health assessments. This study aims to determine sound level differences between the indoors and the outdoors for different window positions and how this sound damping is related to building characteristics. For this purpose, measurements were carried out at home in a sample of 102 Swiss residents exposed to road traffic noise. Sound pressure level recordings were performed outdoors and indoors, in the living room and in the bedroom. Three scenarios-of open, tilted, and closed windows-were recorded for three minutes each. For each situation, data on additional parameters such as the orientation towards the source, floor, and room, as well as sound insulation characteristics were collected. On that basis, linear regression models were established. The median outdoor-indoor sound level differences were of 10 dB(A) for open, 16 dB(A) for tilted, and 28 dB(A) for closed windows. For open and tilted windows, the most relevant parameters affecting the outdoor-indoor differences were the position of the window, the type and volume of the room, and the age of the building. For closed windows, the relevant parameters were the sound level outside, the material of the window frame, the existence of window gaskets, and the number of windows.
46 CFR 298.14 - Economic soundness.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 8 2010-10-01 2010-10-01 false Economic soundness. 298.14 Section 298.14 Shipping... Eligibility § 298.14 Economic soundness. (a) Economic Evaluation. We shall not issue a Letter Commitment for... you seek Title XI financing or refinancing, will be economically sound. The economic soundness and...
46 CFR 298.14 - Economic soundness.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 8 2012-10-01 2012-10-01 false Economic soundness. 298.14 Section 298.14 Shipping... Eligibility § 298.14 Economic soundness. (a) Economic Evaluation. We shall not issue a Letter Commitment for... you seek Title XI financing or refinancing, will be economically sound. The economic soundness and...
46 CFR 298.14 - Economic soundness.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 8 2013-10-01 2013-10-01 false Economic soundness. 298.14 Section 298.14 Shipping... Eligibility § 298.14 Economic soundness. (a) Economic Evaluation. We shall not issue a Letter Commitment for... you seek Title XI financing or refinancing, will be economically sound. The economic soundness and...
46 CFR 298.14 - Economic soundness.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 8 2014-10-01 2014-10-01 false Economic soundness. 298.14 Section 298.14 Shipping... Eligibility § 298.14 Economic soundness. (a) Economic Evaluation. We shall not issue a Letter Commitment for... you seek Title XI financing or refinancing, will be economically sound. The economic soundness and...
46 CFR 298.14 - Economic soundness.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 8 2011-10-01 2011-10-01 false Economic soundness. 298.14 Section 298.14 Shipping... Eligibility § 298.14 Economic soundness. (a) Economic Evaluation. We shall not issue a Letter Commitment for... you seek Title XI financing or refinancing, will be economically sound. The economic soundness and...
Correlation between Identification Accuracy and Response Confidence for Common Environmental Sounds
set of environmental sounds with stimulus control and precision. The present study is one in a series of efforts to provide a baseline evaluation of a...sounds from six broad categories: household items, alarms, animals, human generated, mechanical, and vehicle sounds. Each sound was presented five times
Noise levels and their effects on Shuttle crewmembers' performance: Operational concerns
NASA Technical Reports Server (NTRS)
Koros, Anton S.; Adam, Susan C.; Wheelwright, Charles D.
1993-01-01
When excessive, noise can result in sleep interference, fatigue, interference with verbal communication, and hearing damage. Shuttle crewmembers are exposed to noise throughout their mission. The contribution of noise to decrements in crew performance over these extended exposure durations was the focus of this study. On the STS-40/SLS-1, mission noise levels were evaluated through the use of a sound level meter and a crew questionnaire. Crewmembers noted that sleep, concentration, and relaxation were negatively impacted by high noise levels. Speech Interference Levels (SIL's), calculated from the sound level measurements, suggested that crewmembers were required to raise their voice in order to be heard. No difficulty detecting caution and warning alarms was noted. The higher than desirable noise levels in Spacelab were attributed to flight specific payloads for which acoustic waivers were granted. It is recommended that current noise levels be reduced in Spacelab and the Orbiter Middeck especially as longer missions are planned for the buildup of Space Station Freedom. Levels of NC 50 are recommended in areas where speech communication is required and NC 40 in sleep areas. These levels are in accordance with the NASA Man-Systems Integration Standards. Measurements proposed for subsequent orbiter missions are discussed.
Science and Technology Investment Strategy for Squadron Level Training
1993-05-01
be derived from empirically sound and theory -based instructional models. Cmment. The automation of instructional design could favorably impact the...require a significant amount of time to develop and where the underlying theory and/or applications hardware and software is ht flux. Long-term efforts...training or training courses. It does not refer to the initial evaluation of individuals entering Upgrade Training ( UGT ). It Am refer to the evaluation of
Delgutte, Bertrand
2015-01-01
At lower levels of sensory processing, the representation of a stimulus feature in the response of a neural population can vary in complex ways across different stimulus intensities, potentially changing the amount of feature-relevant information in the response. How higher-level neural circuits could implement feature decoding computations that compensate for these intensity-dependent variations remains unclear. Here we focused on neurons in the inferior colliculus (IC) of unanesthetized rabbits, whose firing rates are sensitive to both the azimuthal position of a sound source and its sound level. We found that the azimuth tuning curves of an IC neuron at different sound levels tend to be linear transformations of each other. These transformations could either increase or decrease the mutual information between source azimuth and spike count with increasing level for individual neurons, yet population azimuthal information remained constant across the absolute sound levels tested (35, 50, and 65 dB SPL), as inferred from the performance of a maximum-likelihood neural population decoder. We harnessed evidence of level-dependent linear transformations to reduce the number of free parameters in the creation of an accurate cross-level population decoder of azimuth. Interestingly, this decoder predicts monotonic azimuth tuning curves, broadly sensitive to contralateral azimuths, in neurons at higher levels in the auditory pathway. PMID:26490292
NASA Technical Reports Server (NTRS)
Gray, R. B.; Pierce, G. A.
1972-01-01
Wind tunnel tests were performed on two oscillating two-dimensional lifting surfaces. The first of these models had an NACA 0012 airfoil section while the second simulated the classical flat plate. Both of these models had a mean angle of attack of 12 degrees while being oscillated in pitch about their midchord with a double amplitude of 6 degrees. Wake surveys of sound pressure level were made over a frequency range from 16 to 32 Hz and at various free stream velocities up to 100 ft/sec. The sound pressure level spectrum indicated significant peaks in sound intensity at the oscillation frequency and its first harmonic near the wake of both models. From a comparison of these data with that of a sound level meter, it is concluded that most of the sound intensity is contained within these peaks and no appreciable peaks occur at higher harmonics. It is concluded that within the wake the sound intensity is largely pseudosound while at one chord length outside the wake, it is largely true vortex sound. For both the airfoil and flat plate the peaks appear to be more strongly dependent upon the airspeed than on the oscillation frequency. Therefore reduced frequency does not appear to be a significant parameter in the generation of wake sound intensity.
Kastelein, Ronald A; van der Heul, Sander; Verboom, Willem C; Triesscheijn, Rob J V; Jennings, Nancy V
2006-02-01
To prevent grounding of ships and collisions between ships in shallow coastal waters, an underwater data collection and communication network (ACME) using underwater sounds to encode and transmit data is currently under development. Marine mammals might be affected by ACME sounds since they may use sound of a similar frequency (around 12 kHz) for communication, orientation, and prey location. If marine mammals tend to avoid the vicinity of the acoustic transmitters, they may be kept away from ecologically important areas by ACME sounds. One marine mammal species that may be affected in the North Sea is the harbour seal (Phoca vitulina). No information is available on the effects of ACME-like sounds on harbour seals, so this study was carried out as part of an environmental impact assessment program. Nine captive harbour seals were subjected to four sound types, three of which may be used in the underwater acoustic data communication network. The effect of each sound was judged by comparing the animals' location in a pool during test periods to that during baseline periods, during which no sound was produced. Each of the four sounds could be made into a deterrent by increasing its amplitude. The seals reacted by swimming away from the sound source. The sound pressure level (SPL) at the acoustic discomfort threshold was established for each of the four sounds. The acoustic discomfort threshold is defined as the boundary between the areas that the animals generally occupied during the transmission of the sounds and the areas that they generally did not enter during transmission. The SPLs at the acoustic discomfort thresholds were similar for each of the sounds (107 dB re 1 microPa). Based on this discomfort threshold SPL, discomfort zones at sea for several source levels (130-180 dB re 1 microPa) of the sounds were calculated, using a guideline sound propagation model for shallow water. The discomfort zone is defined as the area around a sound source that harbour seals are expected to avoid. The definition of the discomfort zone is based on behavioural discomfort, and does not necessarily coincide with the physical discomfort zone. Based on these results, source levels can be selected that have an acceptable effect on harbour seals in particular areas. The discomfort zone of a communication sound depends on the sound, the source level, and the propagation characteristics of the area in which the sound system is operational. The source level of the communication system should be adapted to each area (taking into account the width of a sea arm, the local sound propagation, and the importance of an area to the affected species). The discomfort zone should not coincide with ecologically important areas (for instance resting, breeding, suckling, and feeding areas), or routes between these areas.
Sakamoto, Maki; Watanabe, Junji
2016-03-01
Many languages have a word class whose speech sounds are linked to sensory experiences. Several recent studies have demonstrated cross-modal associations (or correspondences) between sounds and gustatory sensations by asking participants to match predefined sound-symbolic words (e.g., "maluma/takete") with the taste/texture of foods. Here, we further explore cross-modal associations using the spontaneous production of words and semantic ratings of sensations. In the experiment, after drinking liquids, participants were asked to express their taste/texture using Japanese sound-symbolic words, and at the same time, to evaluate it in terms of criteria expressed by adjectives. Because the Japanese language has a large vocabulary of sound-symbolic words, and Japanese people frequently use them to describe taste/texture, analyzing a variety of Japanese sound-symbolic words spontaneously produced to express taste/textures might enable us to explore the mechanism of taste/texture categorization. A hierarchical cluster analysis based on the relationship between linguistic sounds and taste/texture evaluations revealed the structure of sensation categories. The results indicate that an emotional evaluation like pleasant/unpleasant is the primary cluster in gustation. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Investigation of Noise Field and Velocity Profiles of an Afterburning Engine
NASA Technical Reports Server (NTRS)
North, Warren J.; Callaghan, E. E.; Lanzo, C. D.
1954-01-01
Sound pressure levels, frequency spectrum, and jet velocity profiles are presented for an engine-afterburner combination at various values of afterburner fuel - air ratio. At the high fuel-air ratios, severe low-frequency resonance was encountered which represented more than half the total energy in the sound spectrum. At similar thrust conditions, lower sound pressure levels were obtained from a current fighter air craft with a different afterburner configuration. The lower sound pressure levels are attributed to resonance-free afterburner operation and thereby indicate the importance of acoustic considerations in afterburner design.
Aller, Marta-Beatriz; Vargas, Ingrid; Coderch, Jordi; Calero, Sebastià; Cots, Francesc; Abizanda, Mercè; Farré, Joan; Llopart, Josep Ramon; Colomés, Lluís; Vázquez, María Luisa
2015-08-13
Coordination across levels of care is becoming increasingly important due to rapid advances in technology, high specialisation and changes in the organization of healthcare services; to date, however, the development of indicators to evaluate coordination has been limited. The aim of this study is to develop and test a set of indicators to comprehensively evaluate clinical coordination across levels of care. A systematic review of literature was conducted to identify indicators of clinical coordination across levels of care. These indicators were analysed to identify attributes of coordination and classified accordingly. They were then discussed within an expert team and adapted or newly developed, and their relevance, scientific soundness and feasibility were examined. The indicators were tested in three healthcare areas of the Catalan health system. 52 indicators were identified addressing 11 attributes of clinical coordination across levels of care. The final set consisted of 21 output indicators. Clinical information transfer is evaluated based on information flow (4) and the adequacy of shared information (3). Clinical management coordination indicators evaluate care coherence through diagnostic testing (2) and medication (1), provision of care at the most appropriate level (2), completion of diagnostic process (1), follow-up after hospital discharge (4) and accessibility across levels of care (4). The application of indicators showed differences in the degree of clinical coordination depending on the attribute and area. A set of rigorous and scientifically sound measures of clinical coordination across levels of care were developed based on a literature review and discussion with experts. This set of indicators comprehensively address the different attributes of clinical coordination in main transitions across levels of care. It could be employed to identify areas in which health services can be improved, as well as to measure the effect of efforts to improve clinical coordination in healthcare organizations.
Effects of Sound on the Behavior of Wild, Unrestrained Fish Schools.
Roberts, Louise; Cheesman, Samuel; Hawkins, Anthony D
2016-01-01
To assess and manage the impact of man-made sounds on fish, we need information on how behavior is affected. Here, wild unrestrained pelagic fish schools were observed under quiet conditions using sonar. Fish were exposed to synthetic piling sounds at different levels using custom-built sound projectors, and behavioral changes were examined. In some cases, the depth of schools changed after noise playback; full dispersal of schools was also evident. The methods we developed for examining the behavior of unrestrained fish to sound exposure have proved successful and may allow further testing of the relationship between responsiveness and sound level.
The influence of sea ice, wind speed and marine mammals on Southern Ocean ambient sound.
Menze, Sebastian; Zitterbart, Daniel P; van Opzeeland, Ilse; Boebel, Olaf
2017-01-01
This paper describes the natural variability of ambient sound in the Southern Ocean, an acoustically pristine marine mammal habitat. Over a 3-year period, two autonomous recorders were moored along the Greenwich meridian to collect underwater passive acoustic data. Ambient sound levels were strongly affected by the annual variation of the sea-ice cover, which decouples local wind speed and sound levels during austral winter. With increasing sea-ice concentration, area and thickness, sound levels decreased while the contribution of distant sources increased. Marine mammal sounds formed a substantial part of the overall acoustic environment, comprising calls produced by Antarctic blue whales ( Balaenoptera musculus intermedia ), fin whales ( Balaenoptera physalus ), Antarctic minke whales ( Balaenoptera bonaerensis ) and leopard seals ( Hydrurga leptonyx ). The combined sound energy of a group or population vocalizing during extended periods contributed species-specific peaks to the ambient sound spectra. The temporal and spatial variation in the contribution of marine mammals to ambient sound suggests annual patterns in migration and behaviour. The Antarctic blue and fin whale contributions were loudest in austral autumn, whereas the Antarctic minke whale contribution was loudest during austral winter and repeatedly showed a diel pattern that coincided with the diel vertical migration of zooplankton.
The influence of sea ice, wind speed and marine mammals on Southern Ocean ambient sound
NASA Astrophysics Data System (ADS)
Menze, Sebastian; Zitterbart, Daniel P.; van Opzeeland, Ilse; Boebel, Olaf
2017-01-01
This paper describes the natural variability of ambient sound in the Southern Ocean, an acoustically pristine marine mammal habitat. Over a 3-year period, two autonomous recorders were moored along the Greenwich meridian to collect underwater passive acoustic data. Ambient sound levels were strongly affected by the annual variation of the sea-ice cover, which decouples local wind speed and sound levels during austral winter. With increasing sea-ice concentration, area and thickness, sound levels decreased while the contribution of distant sources increased. Marine mammal sounds formed a substantial part of the overall acoustic environment, comprising calls produced by Antarctic blue whales (Balaenoptera musculus intermedia), fin whales (Balaenoptera physalus), Antarctic minke whales (Balaenoptera bonaerensis) and leopard seals (Hydrurga leptonyx). The combined sound energy of a group or population vocalizing during extended periods contributed species-specific peaks to the ambient sound spectra. The temporal and spatial variation in the contribution of marine mammals to ambient sound suggests annual patterns in migration and behaviour. The Antarctic blue and fin whale contributions were loudest in austral autumn, whereas the Antarctic minke whale contribution was loudest during austral winter and repeatedly showed a diel pattern that coincided with the diel vertical migration of zooplankton.
ERIC Educational Resources Information Center
California State Dept. of Education, Sacramento.
California has conducted on-site sound surveys of 36 different schools to determine the degree of noise, and thus disturbance, within the learning environment. This report provides the methodology and results of the survey, including descriptive charts and graphs illustrating typical desirable and undesirable sound levels. Results are presented…
Code of Federal Regulations, 2010 CFR
2010-07-01
... 85 dBA, or equivalently a dose of 50%, integrating all sound levels from 80 dBA to at least 130 dBA... Protection Level. A TWA8 of 105 dBA, or equivalently, a dose of 800% of that permitted by the standard, integrating all sound levels from 90 dBA to at least 140 dBA. Exchange rate. The amount of increase in sound...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 85 dBA, or equivalently a dose of 50%, integrating all sound levels from 80 dBA to at least 130 dBA... Protection Level. A TWA8 of 105 dBA, or equivalently, a dose of 800% of that permitted by the standard, integrating all sound levels from 90 dBA to at least 140 dBA. Exchange rate. The amount of increase in sound...
40 CFR 201.11 - Standard for locomotive operation under stationary conditions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... completed on or before December 31, 1979, which produces A-weighted sound levels in excess of 93 dB at any..., 1979, which produces A-weighted sound levels in excess of 87 dB at any throttle setting except idle... December 31, 1979, which produces A-weighted sound levels in excess of 87 dB at any throttle setting except...
40 CFR 201.11 - Standard for locomotive operation under stationary conditions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... completed on or before December 31, 1979, which produces A-weighted sound levels in excess of 93 dB at any..., 1979, which produces A-weighted sound levels in excess of 87 dB at any throttle setting except idle... December 31, 1979, which produces A-weighted sound levels in excess of 87 dB at any throttle setting except...
49 CFR 325.73 - Microphone distance correction factors. 1
Code of Federal Regulations, 2011 CFR
2011-10-01
... factors. 1 1 Table 1, in § 325.7 is a tabulation of the maximum allowable sound level readings taking into... target point is other than 50 feet (15.2 m), the maximum observed sound level reading generated by the... observed sound level readings generated by the motor vehicle in accordance with § 325.59 of this part shall...
49 CFR 325.73 - Microphone distance correction factors. 1
Code of Federal Regulations, 2010 CFR
2010-10-01
... factors. 1 1 Table 1, in § 325.7 is a tabulation of the maximum allowable sound level readings taking into... target point is other than 50 feet (15.2 m), the maximum observed sound level reading generated by the... observed sound level readings generated by the motor vehicle in accordance with § 325.59 of this part shall...
The annoyance of impulsive helicopter noise
NASA Technical Reports Server (NTRS)
Karamcheti, K.
1981-01-01
A total of 96 impulsive and non-impulsive sounds were rated for annoyance by 10 subjects. The signals had the same amplitude spectrum with a maximum frequency of 4.75 kHz. By changing the phase of the spectral components different levels of impulsivity were obtained. The signals had coefficients of impulsivity of 10,8, 7,9, and -0.2 respectively. Further, signals had intensity levels 89 and 95 dBA, pulse repetition rates 10 and 20 Hz, and half the signals had pink noise added at a level 12 dBA lower than the level of the sound. The significant results were: The four females and six male subjects rated the impulsive sounds respectively 3.7 dB less annoying and 2.6 dB more annoying than the non-impulsive sounds. Overall, impulsivity had no effect. The hish pulse repetition rate increased annoyance by 2.2 dB. Addition of pink noise increased annoyance of the non-impulsive sounds 1.2 dB, but decreased the annoyance of the impulsive sounds 0.5 dB.
Sound level-dependent growth of N1m amplitude with low and high-frequency tones.
Soeta, Yoshiharu; Nakagawa, Seiji
2009-04-22
The aim of this study was to determine whether the amplitude and/or latency of the N1m deflection of auditory-evoked magnetic fields are influenced by the level and frequency of sound. The results indicated that the amplitude of the N1m increased with sound level. The growth in amplitude with increasing sound level was almost constant with low frequencies (250-1000 Hz); however, this growth decreased with high frequencies (>2000 Hz). The behavior of the amplitude may reflect a difference in the increase in the activation of the peripheral and/or central auditory systems.
What the Toadfish Ear Tells the Toadfish Brain About Sound.
Edds-Walton, Peggy L
2016-01-01
Of the three, paired otolithic endorgans in the ear of teleost fishes, the saccule is the one most often demonstrated to have a major role in encoding frequencies of biologically relevant sounds. The toadfish saccule also encodes sound level and sound source direction in the phase-locked activity conveyed via auditory afferents to nuclei of the ipsilateral octaval column in the medulla. Although paired auditory receptors are present in teleost fishes, binaural processes were believed to be unimportant due to the speed of sound in water and the acoustic transparency of the tissues in water. In contrast, there are behavioral and anatomical data that support binaural processing in fishes. Studies in the toadfish combined anatomical tract-tracing and physiological recordings from identified sites along the ascending auditory pathway to document response characteristics at each level. Binaural computations in the medulla and midbrain sharpen the directional information provided by the saccule. Furthermore, physiological studies in the central nervous system indicated that encoding frequency, sound level, temporal pattern, and sound source direction are important components of what the toadfish ear tells the toadfish brain about sound.
Evaluation of Canine Sperm and Management of Semen Disorders.
Kolster, Kara A
2018-04-17
Semen evaluation of the male dog is a critical step in any canine infertility work-up. Assessment of total sperm count, sperm viability, and sperm morphology are the mainstay of breeding soundness evaluation. Adjunct tests, such as ultrasonography and serum hormone levels, can aid in diagnosis. Pharmacologic treatments, dietary supplements, and management practices may help improve breeding success in subfertile dogs. This article discusses a clinically practical approach to assessing sperm abnormalities and fertility in male dogs. Copyright © 2018 Elsevier Inc. All rights reserved.
Clinical evaluation of the 3M Littmann Electronic Stethoscope Model 3200 in 150 cats.
Blass, Keith A; Schober, Karsten E; Bonagura, John D; Scansen, Brian A; Visser, Lance C; Lu, Jennifer; Smith, Danielle N; Ward, Jessica L
2013-10-01
Detection of murmurs and gallops may help to identify cats with heart disease. However, auscultatory findings may be subject to clinically relevant observer variation. The objective of this study was to evaluate an electronic stethoscope (ES) in cats. We hypothesized that the ES would perform at least as well as a conventional stethoscope (CS) in the detection of abnormal heart sounds. One hundred and fifty consecutive cats undergoing echocardiography were enrolled prospectively. Cats were ausculted with a CS (WA Tycos Harvey Elite) by two observers, and heart sounds were recorded digitally using an ES (3M Littmann Stethoscope Model 3200) for off-line analysis. Echocardiography was used as the clinical standard method for validation of auscultatory findings. Additionally, digital recordings (DRs) were assessed by eight independent observers with various levels of expertise, and compared using interclass correlation and Cohen's weighted kappa analyses. Using the CS, a heart murmur (n = 88 cats) or gallop sound (n = 17) was identified in 105 cats, whereas 45 cats lacked abnormal heart sounds. There was good total agreement (83-90%) between the two observers using the CS. In contrast, there was only moderate agreement (P <0.001) between results from the CS and the DRs for murmurs, and poor agreement for gallops. The CS was more sensitive compared with the DRs with regard to murmurs and gallops. Agreement among the eight observers was good-to-excellent for murmur detection (81%). In conclusion, DRs made with the ES are less sensitive but comparably specific to a CS at detecting abnormal heart sounds in cats.
Parra, Johanna; de Suremain, Aurelie; Berne Audeoud, Frederique; Ego, Anne; Debillon, Thierry
2017-12-01
This study measured sound levels in a 2008 built French neonatal intensive care unit (NICU) and compared them to the 2007 American Academy of Pediatrics (AAP) recommendations. The ultimate aim was to identify factors that could influence noise levels. The study measured sound in 17 single or double rooms in the NICU. Two dosimeters were installed in each room, one inside and one outside the incubators, and these conducted measurements over a 24-hour period. The noise metrics measured were the equivalent continuous sound level (L eq ), the maximum noise level (L max ) and the noise level exceeded for 10% of the measurement period (L 10 ). The mean L eq , L 10 and L max were 60.4, 62.1 and 89.1 decibels (dBA), which exceeded the recommended levels of 45, 50 and 65 dBA (p < 0.001), respectively. The L eq inside the incubator was significantly higher than in the room (+8 dBA, p < 0.001). None of the newborns' characteristics, the environment or medical care was correlated to an increased noise level, except for a postconceptional age below 32 weeks. The sound levels significantly exceeded the AAP recommendations, particularly inside incubators. A multipronged strategy is required to improve the sound environment and protect the neonates' sensory development. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.
MP3 player listening sound pressure levels among 10 to 17 year old students.
Keith, Stephen E; Michaud, David S; Feder, Katya; Haider, Ifaz; Marro, Leonora; Thompson, Emma; Marcoux, Andre M
2011-11-01
Using a manikin, equivalent free-field sound pressure level measurements were made from the portable digital audio players of 219 subjects, aged 10 to 17 years (93 males) at their typical and "worst-case" volume levels. Measurements were made in different classrooms with background sound pressure levels between 40 and 52 dBA. After correction for the transfer function of the ear, the median equivalent free field sound pressure levels and interquartile ranges (IQR) at typical and worst-case volume settings were 68 dBA (IQR = 15) and 76 dBA (IQR = 19), respectively. Self-reported mean daily use ranged from 0.014 to 12 h. When typical sound pressure levels were considered in combination with the average daily duration of use, the median noise exposure level, Lex, was 56 dBA (IQR = 18) and 3.2% of subjects were estimated to exceed the most protective occupational noise exposure level limit in Canada, i.e., 85 dBA Lex. Under worst-case listening conditions, 77.6% of the sample was estimated to listen to their device at combinations of sound pressure levels and average daily durations for which there is no known risk of permanent noise-induced hearing loss, i.e., ≤ 75 dBA Lex. Sources and magnitudes of measurement uncertainties are also discussed.
41 CFR 50-204.10 - Occupational noise exposure.
Code of Federal Regulations, 2010 CFR
2010-07-01
... determined as follows: EC21OC91.015 Equivalent sound level contours. Octave band sound pressure levels may be... level dBA slow response 8 90 6 92 4 95 3 97 2 100 11/2 102 1 105 1/2 110 1/4 or less 115 1 When the... not exceed 140 dB peak sound pressure level. [34 FR 7946, May 20, 1969, as amended at 35 FR 1015, Jan...
41 CFR 50-204.10 - Occupational noise exposure.
Code of Federal Regulations, 2011 CFR
2011-07-01
... determined as follows: EC21OC91.015 Equivalent sound level contours. Octave band sound pressure levels may be... level dBA slow response 8 90 6 92 4 95 3 97 2 100 11/2 102 1 105 1/2 110 1/4 or less 115 1 When the... not exceed 140 dB peak sound pressure level. [34 FR 7946, May 20, 1969, as amended at 35 FR 1015, Jan...
Clinical Validation of a Sound Processor Upgrade in Direct Acoustic Cochlear Implant Subjects
Kludt, Eugen; D’hondt, Christiane; Lenarz, Thomas; Maier, Hannes
2017-01-01
Objective: The objectives of the investigation were to evaluate the effect of a sound processor upgrade on the speech reception threshold in noise and to collect long-term safety and efficacy data after 2½ to 5 years of device use of direct acoustic cochlear implant (DACI) recipients. Study Design: The study was designed as a mono-centric, prospective clinical trial. Setting: Tertiary referral center. Patients: Fifteen patients implanted with a direct acoustic cochlear implant. Intervention: Upgrade with a newer generation of sound processor. Main Outcome Measures: Speech recognition test in quiet and in noise, pure tone thresholds, subject-reported outcome measures. Results: The speech recognition in quiet and in noise is superior after the sound processor upgrade and stable after long-term use of the direct acoustic cochlear implant. The bone conduction thresholds did not decrease significantly after long-term high level stimulation. Conclusions: The new sound processor for the DACI system provides significant benefits for DACI users for speech recognition in both quiet and noise. Especially the noise program with the use of directional microphones (Zoom) allows DACI patients to have much less difficulty when having conversations in noisy environments. Furthermore, the study confirms that the benefits of the sound processor upgrade are available to the DACI recipients even after several years of experience with a legacy sound processor. Finally, our study demonstrates that the DACI system is a safe and effective long-term therapy. PMID:28406848
Sound Levels and Risk Perceptions of Music Students During Classes.
Rodrigues, Matilde A; Amorim, Marta; Silva, Manuela V; Neves, Paula; Sousa, Aida; Inácio, Octávio
2015-01-01
It is well recognized that professional musicians are at risk of hearing damage due to the exposure to high sound pressure levels during music playing. However, it is important to recognize that the musicians' exposure may start early in the course of their training as students in the classroom and at home. Studies regarding sound exposure of music students and their hearing disorders are scarce and do not take into account important influencing variables. Therefore, this study aimed to describe sound level exposures of music students at different music styles, classes, and according to the instrument played. Further, this investigation attempted to analyze the perceptions of students in relation to exposure to loud music and consequent health risks, as well as to characterize preventive behaviors. The results showed that music students are exposed to high sound levels in the course of their academic activity. This exposure is potentiated by practice outside the school and other external activities. Differences were found between music style, instruments, and classes. Tinnitus, hyperacusis, diplacusis, and sound distortion were reported by the students. However, students were not entirely aware of the health risks related to exposure to high sound pressure levels. These findings reflect the importance of starting intervention in relation to noise risk reduction at an early stage, when musicians are commencing their activity as students.
Underwater sound of rigid-hulled inflatable boats.
Erbe, Christine; Liong, Syafrin; Koessler, Matthew Walter; Duncan, Alec J; Gourlay, Tim
2016-06-01
Underwater sound of rigid-hulled inflatable boats was recorded 142 times in total, over 3 sites: 2 in southern British Columbia, Canada, and 1 off Western Australia. Underwater sound peaked between 70 and 400 Hz, exhibiting strong tones in this frequency range related to engine and propeller rotation. Sound propagation models were applied to compute monopole source levels, with the source assumed 1 m below the sea surface. Broadband source levels (10-48 000 Hz) increased from 134 to 171 dB re 1 μPa @ 1 m with speed from 3 to 16 m/s (10-56 km/h). Source power spectral density percentile levels and 1/3 octave band levels are given for use in predictive modeling of underwater sound of these boats as part of environmental impact assessments.
Cost-effective control of nitrogen loadings in Long Island Sound
NASA Astrophysics Data System (ADS)
Bennett, Lynne L.; Thorpe, Steven G.; Guse, A. Joseph
2000-12-01
Long Island Sound is plagued by conditions of severe hypoxia (low levels of dissolved oxygen) during the summer months because of the existence of excessive amounts of nitrogen. A new proposal that would allow sewage treatment plants to buy or sell nitrogen discharge credits is currently being evaluated by the states of Connecticut and New York. Existing theory suggests that a trading program for nitrogen emissions would be a cost-effective means of addressing the problem. We estimate the costs associated with several trading scenarios and find that the potential for cost savings is substantial and that cost savings rise as the scope of trading expands.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brandenberger, Jill M.; Suslick, Carolynn R.; Johnston, Robert K.
2008-10-09
Evaluating spatial and temporal trends in contaminant residues in Puget Sound fish and macroinvertebrates are the objectives of the Puget Sound Ambient Monitoring Program (PSAMP). In a cooperative effort between the ENVironmental inVESTment group (ENVVEST) and Washington State Department of Fish and Wildlife, additional biota samples were collected during the 2007 PSAMP biota survey and analyzed for chemical residues and stable isotopes of carbon (δ13C) and nitrogen (δ15N). Approximately three specimens of each species collected from Sinclair Inlet, Georgia Basin, and reference locations in Puget Sound were selected for whole body chemical analysis. The muscle tissue of specimens selected formore » chemical analyses were also analyzed for δ13C and δ15N to provide information on relative trophic level and food sources. This data report summarizes the chemical residues for the 2007 PSAMP fish and macro-invertebrate samples. In addition, six Spiny Dogfish (Squalus acanthias) samples were necropsied to evaluate chemical residue of various parts of the fish (digestive tract, liver, embryo, muscle tissue), as well as, a weight proportional whole body composite (WBWC). Whole organisms were homogenized and analyzed for silver, arsenic, cadmium, chromium, copper, nickel, lead, zinc, mercury, 19 polychlorinated biphenyl (PCB) congeners, PCB homologues, percent moisture, percent lipids, δ13C, and δ15N.« less
Davidson, J.; Bebak, J.; Mazik, P.
2009-01-01
Intensive aquaculture systems, particularly recirculating systems, utilize equipment such as aerators, air and water pumps, blowers, and filtration systems that inadvertently increase noise levels in fish culture tanks. Sound levels and frequencies measured within intensive aquaculture systems are within the range of fish hearing, but species-specific effects of aquaculture production noise are not well defined. Field and laboratory studies have shown that fish behavior and physiology can be negatively impacted by intense sound. Therefore, chronic exposure to aquaculture production noise could cause increased stress, reduced growth rates and feed conversion efficiency, and decreased survival. The objective of this study was to provide an in-depth evaluation of the long term effects of aquaculture production noise on the growth, condition factor, feed conversion efficiency, and survival of cultured rainbow trout, Oncorhynchus mykiss. Rainbow trout were cultured in replicated tanks using two sound treatments: 117??dB re 1????Pa RMS which represented sound levels lower than those recorded in an intensive recycle system and 149??dB re 1????Pa RMS, representing sound levels near the upper limits known to occur in recycle systems. To begin the study mean fish weights in the 117 and 149??dB tanks were 40 and 39??g, respectively. After five months of exposure no significant differences were identified between treatments for mean weight, length, specific growth rates, condition factor, feed conversion, or survival (n = 4). Mean final weights for the 117 and 149??dB treatments were 641 ?? 3 and 631 ?? 10??g, respectively. Overall specific growth rates were equal, i.e. 1.84 ?? 0.00 and 1.84 ?? 0.01%/day. Analysis of growth rates of individually tagged rainbow trout indicated that fish from the 149??dB tanks grew slower during the first month of noise exposure (p < 0.05); however, fish acclimated to the noise thereafter. This study further suggests that rainbow trout growth and survival are unlikely to be affected over the long term by noise levels common to intensive aquaculture systems. ?? 2008 Elsevier B.V.
NASA Astrophysics Data System (ADS)
Sosa, Germán. D.; Cruz-Roa, Angel; González, Fabio A.
2015-01-01
This work addresses the problem of lung sound classification, in particular, the problem of distinguishing between wheeze and normal sounds. Wheezing sound detection is an important step to associate lung sounds with an abnormal state of the respiratory system, usually associated with tuberculosis or another chronic obstructive pulmonary diseases (COPD). The paper presents an approach for automatic lung sound classification, which uses different state-of-the-art sound features in combination with a C-weighted support vector machine (SVM) classifier that works better for unbalanced data. Feature extraction methods used here are commonly applied in speech recognition and related problems thanks to the fact that they capture the most informative spectral content from the original signals. The evaluated methods were: Fourier transform (FT), wavelet decomposition using Wavelet Packet Transform bank of filters (WPT) and Mel Frequency Cepstral Coefficients (MFCC). For comparison, we evaluated and contrasted the proposed approach against previous works using different combination of features and/or classifiers. The different methods were evaluated on a set of lung sounds including normal and wheezing sounds. A leave-two-out per-case cross-validation approach was used, which, in each fold, chooses as validation set a couple of cases, one including normal sounds and the other including wheezing sounds. Experimental results were reported in terms of traditional classification performance measures: sensitivity, specificity and balanced accuracy. Our best results using the suggested approach, C-weighted SVM and MFCC, achieve a 82.1% of balanced accuracy obtaining the best result for this problem until now. These results suggest that supervised classifiers based on kernel methods are able to learn better models for this challenging classification problem even using the same feature extraction methods.
Effects of unilateral laser-assisted ventriculocordectomy in horses with laryngeal hemiplegia.
Robinson, P; Derksen, F J; Stick, J A; Sullins, K E; DeTolve, P G; Robinson, N E
2006-11-01
Recent studies have evaluated surgical techniques aimed at reducing noise and improving airway function in horses with recurrent laryngeal neuropathy (RLN). These techniques require general anaesthesia and are invasive. A minimally invasive transnasal surgical technique for treatment of RLN that may be employed in the standing, sedated horse would be advantageous. To determine whether unilateral laser-assisted ventriculocordectomy (LVC) improves upper airway function and reduces noise during inhalation in exercising horses with laryngeal hemiplegia (LH). Six Standardbred horses were used; respiratory sound and inspiratory transupper airway pressure (Pui) measured before and after induction of LH, and 60, 90 and 120 days after LVC. Inspiratory sound level (SL) and the sound intensities of formants 1, 2 and 3 (Fl, F2 and F3, respectively), were measured using computer-based sound analysis programmes. In addition, upper airway endoscopy was performed at each time interval, at rest and during treadmill exercise. In LH-affected horses, Pui, SL and the sound intensity of F2 and F3 were increased significantly from baseline values. At 60 days after LVC, Pui and SL had returned to baseline, and F2 and F3 values had improved partially compared to LH values. At 90 and 120 days, however, SL increased again to LH levels. LVC decreases LH-associated airway obstruction by 60 days after surgery, and reduces inspiratory noise but not as effectively as bilateral ventriculocordectomy. LVC may be recommended as a treatment of LH, where reduction of upper airway obstruction and respiratory noise is desired and the owner wishes to avoid risks associated with a laryngotomy incision or general anaesthesia.
Nelting, M; Rienhoff, N K; Hesse, G; Lamparter, U
2002-05-01
So far there has been no adequate measure to assess or illustrate, in terms of different levels, subjective distress related to hypersensitivity to sound. The here presented work describes and discusses the construction of a questionnaire to assess subjective distress related to hypersensitivity to sound (GUF). Between May and September 2000 226 patients that experienced suffering from hypersensitivity to sound as well as from chronic tinnitus, completed a first version of the questionnaire on admittance to the hospital. Of these patients 27.9 % were out-patients and 72.1 % were in-patients. In addition, the in-patients completed the questionnaire again during their last week of treatment. The 27 items of the GUF were interpreted by factor analysis to explore and determine the structure of the questionnaire; the number of items was reduced under the aspects of consistency and reliability. Finally, the revised version of the GUF underwent a first validation. The factor analysis shows three factors explaining 50.65 % variance (factor 1 [KRH], cognitive reactions to hyperacusis; factor 2 [ASV], actional/somatic behaviour; factor 3 [ERG], emotional reaction to external noises). First attempts to validate the questionnaire are promising; it appears that the GUF is also sensitive to therapy effects. The here presented questionnaire is suitable for identifying distinct levels of subjective distress related to hypersensitivity to sound. Thus, for the first time, there is an adequate measure for assessment available. Furthermore, results of part of the sample show that the GUF is also suitable for therapy evaluation.
Graded behavioral responses and habituation to sound in the common cuttlefish Sepia officinalis.
Samson, Julia E; Mooney, T Aran; Gussekloo, Sander W S; Hanlon, Roger T
2014-12-15
Sound is a widely available and vital cue in aquatic environments, yet most bioacoustic research has focused on marine vertebrates, leaving sound detection in invertebrates poorly understood. Cephalopods are an ecologically key taxon that likely use sound and may be impacted by increasing anthropogenic ocean noise, but little is known regarding their behavioral responses or adaptations to sound stimuli. These experiments identify the acoustic range and levels that elicit a wide range of secondary defense behaviors such as inking, jetting and rapid coloration change. Secondarily, it was found that cuttlefish habituate to certain sound stimuli. The present study examined the behavioral responses of 22 cuttlefish (Sepia officinalis) to pure-tone pips ranging from 80 to 1000 Hz with sound pressure levels of 85-188 dB re. 1 μPa rms and particle accelerations of 0-17.1 m s(-2). Cuttlefish escape responses (inking, jetting) were observed between frequencies of 80 and 300 Hz and at sound levels above 140 dB re. 1 μPa rms and 0.01 m s(-2) (0.74 m s(-2) for inking responses). Body patterning changes and fin movements were observed at all frequencies and sound levels. Response intensity was dependent upon stimulus amplitude and frequency, suggesting that cuttlefish also possess loudness perception with a maximum sensitivity around 150 Hz. Cuttlefish habituated to repeated 200 Hz tone pips, at two sound intensities. Total response inhibition was not reached, however, and a basal response remained present in most animals. The graded responses provide a loudness sensitivity curve and suggest an ecological function for sound use in cephalopods. © 2014. Published by The Company of Biologists Ltd.
Rodriguez, Amanda I; Thomas, Megan L A; Fitzpatrick, Denis; Janky, Kristen L
Vestibular evoked myogenic potential (VEMP) testing is increasingly utilized in pediatric vestibular evaluations due to its diagnostic capability to identify otolith dysfunction and feasibility of testing. However, there is evidence demonstrating that the high-intensity stimulation level required to elicit a reliable VEMP response causes acoustic trauma in adults. Despite utility of VEMP testing in children, similar findings are unknown. It is hypothesized that increased sound exposure may exist in children because differences in ear-canal volume (ECV) compared with adults, and the effect of stimulus parameters (e.g., signal duration and intensity) will alter exposure levels delivered to a child's ear. The objectives of this study are to (1) measure peak to peak equivalent sound pressure levels (peSPL) in children with normal hearing (CNH) and young adults with normal hearing (ANH) using high-intensity VEMP stimuli, (2) determine the effect of ECV on peSPL and calculate a safe exposure level for VEMP, and (3) assess whether cochlear changes exist after VEMP exposure. This was a 2-phase approach. Fifteen CNH and 12 ANH participated in phase I. Equivalent ECV was measured. In 1 ear, peSPL was recorded for 5 seconds at 105 to 125 dB SPL, in 5-dB increments for 500- and 750-Hz tone bursts. Recorded peSPL values (accounting for stimulus duration) were then used to calculate safe sound energy exposure values for VEMP testing using the 132-dB recommended energy allowance from the 2003 European Union Guidelines. Fifteen CNH and 10 ANH received cervical and ocular VEMP testing in 1 ear in phase II. Subjects completed tympanometry, pre- and postaudiometric threshold testing, distortion product otoacoustic emissions, and questionnaire addressing subjective otologic symptoms to study the effect of VEMP exposure on cochlear function. (1) In response to high-intensity stimulation levels (e.g., 125 dB SPL), CNH had significantly higher peSPL measurements and smaller ECVs compared with ANH. (2) A significant linear relationship between equivalent ECV (as measured by diagnostic tympanometry) and peSPL exists and has an effect on total sound energy exposure level; based on data from phase I, 120 dB SPL was determined to be an acoustically safe stimulation level for testing in children. (3) Using calculated safe stimulation level for VEMP testing, there were no significant effect of VEMP exposure on cochlear function (as measured by audiometric thresholds, distortion product otoacoustic emission amplitude levels, or subjective symptoms) in CNH and ANH. peSPL sound recordings in children's ears are significantly higher (~3 dB) than that in adults in response to high-intensity VEMP stimuli that are commonly practiced. Equivalent ECV contributes to peSPL delivered to the ear during VEMP testing and should be considered to determine safe acoustic VEMP stimulus parameters; children with smaller ECVs are at risk for unsafe sound exposure during routine VEMP testing, and stimuli should not exceed 120 dB SPL. Using 120 dB SPL stimulus level for children during VEMP testing yields no change to cochlear function and reliable VEMP responses.
Knight, Lisa; Ladich, Friedrich
2014-11-15
Thorny catfishes produce stridulation (SR) sounds using their pectoral fins and drumming (DR) sounds via a swimbladder mechanism in distress situations when hand held in water and in air. It has been argued that SR and DR sounds are aimed at different receivers (predators) in different media. The aim of this study was to analyse and compare sounds emitted in both air and water in order to test different hypotheses on the functional significance of distress sounds. Five representatives of the family Doradidae were investigated. Fish were hand held and sounds emitted in air and underwater were recorded (number of sounds, sound duration, dominant and fundamental frequency, sound pressure level and peak-to-peak amplitudes). All species produced SR sounds in both media, but DR sounds could not be recorded in air for two species. Differences in sound characteristics between media were small and mainly limited to spectral differences in SR. The number of sounds emitted decreased over time, whereas the duration of SR sounds increased. The dominant frequency of SR and the fundamental frequency of DR decreased and sound pressure level of SR increased with body size across species. The hypothesis that catfish produce more SR sounds in air and more DR sounds in water as a result of different predation pressure (birds versus fish) could not be confirmed. It is assumed that SR sounds serve as distress sounds in both media, whereas DR sounds might primarily be used as intraspecific communication signals in water in species possessing both mechanisms. © 2014. Published by The Company of Biologists Ltd.
Helicopter Flight Procedures for Community Noise Reduction
NASA Technical Reports Server (NTRS)
Greenwood, Eric
2017-01-01
A computationally efficient, semiempirical noise model suitable for maneuvering flight noise prediction is used to evaluate the community noise impact of practical variations on several helicopter flight procedures typical of normal operations. Turns, "quick-stops," approaches, climbs, and combinations of these maneuvers are assessed. Relatively small variations in flight procedures are shown to cause significant changes to Sound Exposure Levels over a wide area. Guidelines are developed for helicopter pilots intended to provide effective strategies for reducing the negative effects of helicopter noise on the community. Finally, direct optimization of flight trajectories is conducted to identify low noise optimal flight procedures and quantify the magnitude of community noise reductions that can be obtained through tailored helicopter flight procedures. Physically realizable optimal turns and approaches are identified that achieve global noise reductions of as much as 10 dBA Sound Exposure Level.
Environmental impact on crew of armoured vehicles: Effects of 24 h combat exercise in a hot desert
NASA Astrophysics Data System (ADS)
Singh, A. P.; Majumdar, D.; Bhatia, M. R.; Srivastava, K. K.; Selvamurthy, W.
1995-06-01
A field study was undertaken to investigate the effects of combined noise, vibration and heat stress on the physiological functions of the crew of armoured vehicles during prolonged combat exercise in a desert. The sound pressure level of noise was measured with a sound level meter and accelerations by vibration analyser. The thermal load on the crew was evaluated by calculating the wet bulb globe temperature index. The physiological responses of the subjects ( n=9), included significant increases in the heart rate, 24 h water intake and urinary catecholamine concentration. A significant decrease was recorded in body mass, peak expiratory flow rate and 24 h urinary output. The high heat load on the crew resulted in a hypohydration of 3% body mass and appeared to be the dominant factor in producing the physiological strain.
NASA Astrophysics Data System (ADS)
Nishiura, Takanobu; Nakamura, Satoshi
2003-10-01
Humans communicate with each other through speech by focusing on the target speech among environmental sounds in real acoustic environments. We can easily identify the target sound from other environmental sounds. For hands-free speech recognition, the identification of the target speech from environmental sounds is imperative. This mechanism may also be important for a self-moving robot to sense the acoustic environments and communicate with humans. Therefore, this paper first proposes hidden Markov model (HMM)-based environmental sound source identification. Environmental sounds are modeled by three states of HMMs and evaluated using 92 kinds of environmental sounds. The identification accuracy was 95.4%. This paper also proposes a new HMM composition method that composes speech HMMs and an HMM of categorized environmental sounds for robust environmental sound-added speech recognition. As a result of the evaluation experiments, we confirmed that the proposed HMM composition outperforms the conventional HMM composition with speech HMMs and a noise (environmental sound) HMM trained using noise periods prior to the target speech in a captured signal. [Work supported by Ministry of Public Management, Home Affairs, Posts and Telecommunications of Japan.
An investigation of the sound field above the audience in large lecture halls with a scale model.
Kahn, D W; Tichy, J
1986-09-01
Measurements of steady-state sound pressure levels above the audience in large lecture halls show that the classical equation for predicting the sound pressure level is not accurate. The direct field above the seats was measured on a 1:10 scale model and was found to be dependent on the incidence angle and direction of sound propagation across the audience. The reverberant field above the seats in the model was calculated by subtracting the direct field from the measured total field and was found to be dependent on the magnitude and particularly on the placement of absorption. The decrease of sound pressure level versus distance in the total field depends on the angle (controlled by absorption placement) at which the strong reflections are incident upon the audience area. Sound pressure level decreases at a fairly constant rate with distance from the sound source in both the direct and reverberant field, and the decrease rate depends strongly on the absorption placement. The lowest rate of decay occurs when the side walls are absorptive, and both the ceiling and rear wall are reflective. These consequences are discussed with respect to prediction of speech intelligibility.
Non-auditory health effects among air force crew chiefs exposed to high level sound.
Jensen, Anker; Lund, Søren Peter; Lücke, Thorsten Høgh; Clausen, Ole Voldum; Svendsen, Jørgen Torp
2009-01-01
The possibility of non-auditory health effects in connection with occupational exposure to high level sound is supposed by some researchers, but is still debated. Crew chiefs on airfields are exposed to high-level aircraft sound when working close to aircraft with running engines. We compared their health status with a similar control group who were not subject to this specific sound exposure. Health records of 42 crew chiefs were compared to health records of 42 aircraft mechanics and 17 former crew chiefs. The specific sound exposure of crew chiefs was assessed. The number of reported disease cases was generally small, but generally slightly higher among mechanics than among crew chiefs. Diseases of the ear were more frequent among crew chiefs (not significant). Former crew chiefs reported fewer diseases of the ear and more airways infections (both significant). The sound exposure during launch was up to 144 dB (peak) and 124 dB (L(eq) ), but for limited time. The study did not reveal a higher disease frequency in general among crew chiefs. However, it did reveal a tendency to ear diseases, possibly due to their exposure to high-level sound.
Azimuthal sound localization in the European starling (Sturnus vulgaris): I. Physical binaural cues.
Klump, G M; Larsen, O N
1992-02-01
The physical measurements reported here test whether the European starling (Sturnus vulgaris) evaluates the azimuth direction of a sound source with a peripheral auditory system composed of two acoustically coupled pressure-difference receivers (1) or of two decoupled pressure receivers (2). A directional pattern of sound intensity in the free-field was measured at the entrance of the auditory meatus using a probe microphone, and at the tympanum using laser vibrometry. The maximum differences in the sound-pressure level measured with the microphone between various speaker positions and the frontal speaker position were 2.4 dB at 1 and 2 kHz, 7.3 dB at 4 kHz, 9.2 dB at 6 kHz, and 10.9 dB at 8 kHz. The directional amplitude pattern measured by laser vibrometry did not differ from that measured with the microphone. Neither did the directional pattern of travel times to the ear. Measurements of the amplitude and phase transfer function of the starling's interaural pathway using a closed sound system were in accord with the results of the free-field measurements. In conclusion, although some sound transmission via the interaural canal occurred, the present experiments support the hypothesis 2 above that the starling's peripheral auditory system is best described as consisting of two functionally decoupled pressure receivers.
Short-Range Acoustic Propagation Using Mobile Transmitters Under Arctic Ice Cover
2017-09-01
predict the surface water/ice scattering and absorptive effects on transmitted sound . In addition, sound speed variability by range (usually...receivers at ranges out to 10 kilometers. Sound speed profile data was also measured on site. Transmission loss models were created as a baseline at the...received sound level (on the level of 30 to 40 decibels) at the same range and depth but different directions. 14. SUBJECT TERMS Arctic, Beaufort Sea
75 FR 39915 - Marine Mammals; File No. 15483
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-13
... whales adjust their bearing to avoid received sound pressure levels greater than 120 dB, which would... marine mammals may be taken by Level B harassment as researchers attempt to provoke an avoidance response through sound transmission into their environment. The sound source consists of a transmitter and...
40 CFR 205.54-2 - Sound data acquisition system.
Code of Federal Regulations, 2010 CFR
2010-07-01
... meets the “fast” dynamic requirement of a precision sound level meter indicating meter system for the... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Sound data acquisition system. 205.54... data acquisition system. (a) Systems employing tape recorders and graphic level recorders may be...
An Analysis of Sound Exposure in a University Music Rehearsal
ERIC Educational Resources Information Center
Farmer, Joe; Thrasher, Michael; Fumo, Nelson
2014-01-01
Exposure to high sound levels may lead to a variety of hearing abnormalities, including Noise-Induced Hearing Loss (NIHL). Pre-professional university music majors may experience frequent exposure to elevated sound levels, and this may have implications on their future career prospects (Jansen, Helleman, Dreschler & de Laat, 2009). Studies…
Study of the Acoustic Effects of Hydrokinetic Tidal Turbines in Admiralty Inlet, Puget Sound
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brian Polagye; Jim Thomson; Chris Bassett
2012-03-30
Hydrokinetic turbines will be a source of noise in the marine environment - both during operation and during installation/removal. High intensity sound can cause injury or behavioral changes in marine mammals and may also affect fish and invertebrates. These noise effects are, however, highly dependent on the individual marine animals; the intensity, frequency, and duration of the sound; and context in which the sound is received. In other words, production of sound is a necessary, but not sufficient, condition for an environmental impact. At a workshop on the environmental effects of tidal energy development, experts identified sound produced by turbinesmore » as an area of potentially significant impact, but also high uncertainty. The overall objectives of this project are to improve our understanding of the potential acoustic effects of tidal turbines by: (1) Characterizing sources of existing underwater noise; (2) Assessing the effectiveness of monitoring technologies to characterize underwater noise and marine mammal responsiveness to noise; (3) Evaluating the sound profile of an operating tidal turbine; and (4) Studying the effect of turbine sound on surrogate species in a laboratory environment. This study focuses on a specific case study for tidal energy development in Admiralty Inlet, Puget Sound, Washington (USA), but the methodologies and results are applicable to other turbine technologies and geographic locations. The project succeeded in achieving the above objectives and, in doing so, substantially contributed to the body of knowledge around the acoustic effects of tidal energy development in several ways: (1) Through collection of data from Admiralty Inlet, established the sources of sound generated by strong currents (mobilizations of sediment and gravel) and determined that low-frequency sound recorded during periods of strong currents is non-propagating pseudo-sound. This helped to advance the debate within the marine and hydrokinetics acoustic community as to whether strong currents produce propagating sound. (2) Analyzed data collected from a tidal turbine operating at the European Marine Energy Center to develop a profile of turbine sound and developed a framework to evaluate the acoustic effects of deploying similar devices in other locations. This framework has been applied to Public Utility District No. 1 of Snohomish Country's demonstration project in Admiralty Inlet to inform postinstallation acoustic and marine mammal monitoring plans. (3) Demonstrated passive acoustic techniques to characterize the ambient noise environment at tidal energy sites (fixed, long-term observations recommended) and characterize the sound from anthropogenic sources (drifting, short-term observations recommended). (4) Demonstrated the utility and limitations of instrumentation, including bottom mounted instrumentation packages, infrared cameras, and vessel monitoring systems. In doing so, also demonstrated how this type of comprehensive information is needed to interpret observations from each instrument (e.g., hydrophone data can be combined with vessel tracking data to evaluate the contribution of vessel sound to ambient noise). (5) Conducted a study that suggests harbor porpoise in Admiralty Inlet may be habituated to high levels of ambient noise due to omnipresent vessel traffic. The inability to detect behavioral changes associated with a high intensity source of opportunity (passenger ferry) has informed the approach for post-installation marine mammal monitoring. (6) Conducted laboratory exposure experiments of juvenile Chinook salmon and showed that exposure to a worse than worst case acoustic dose of turbine sound does not result in changes to hearing thresholds or biologically significant tissue damage. Collectively, this means that Chinook salmon may be at a relatively low risk of injury from sound produced by tidal turbines located in or near their migration path. In achieving these accomplishments, the project has significantly advanced the District's goals of developing a demonstration-scale tidal energy project in Admiralty Inlet. Pilot demonstrations of this type are an essential step in the development of commercial-scale tidal energy in the United States. This is a renewable resource capable of producing electricity in a highly predictable manner.« less
Evaluation of several non-reflecting computational boundary conditions for duct acoustics
NASA Technical Reports Server (NTRS)
Watson, Willie R.; Zorumski, William E.; Hodge, Steve L.
1994-01-01
Several non-reflecting computational boundary conditions that meet certain criteria and have potential applications to duct acoustics are evaluated for their effectiveness. The same interior solution scheme, grid, and order of approximation are used to evaluate each condition. Sparse matrix solution techniques are applied to solve the matrix equation resulting from the discretization. Modal series solutions for the sound attenuation in an infinite duct are used to evaluate the accuracy of each non-reflecting boundary conditions. The evaluations are performed for sound propagation in a softwall duct, for several sources, sound frequencies, and duct lengths. It is shown that a recently developed nonlocal boundary condition leads to sound attenuation predictions considerably more accurate for short ducts. This leads to a substantial reduction in the number of grid points when compared to other non-reflecting conditions.
Underwater sound radiation patterns of contemporary merchant ships
NASA Astrophysics Data System (ADS)
Gassmann, M.; Wiggins, S. M.; Hildebrand, J. A.
2016-12-01
Merchant ships radiate underwater sound as an unintended by-product of their operation and as consequence contribute significantly to low-frequency, man-made noise in the ocean. Current measurement standards for the description of underwater sound from ships (ISO 17208-1:2016 and ANSI S12.64-2009) require nominal hydrophone depths of 15°, 30° and 45° at the starboard and portside of the test vessel.To opportunistically study the underwater sound of contemporary merchant ships that were tracked by the Automatic Identification System (AIS), an array of seven high-frequency acoustic recording packages (HARPs) with a sampling frequency of 200 kHz was deployed in the Santa Barbara Channel in the primary outgoing shipping lane for the port of Los Angeles and Long Beach. The vertical and horizontal aperture of the array allowed for starboard and portside measurements at all standard-required nominal hydrophone depths in addition to measurements taken at the keel aspect. Based on these measurements, frequency-dependent radiation patterns of contemporary merchant ships were estimated and used to evaluate current standards for computing ship source levels.
Sapienza, C M; Crandell, C C; Curtis, B
1999-09-01
Voice problems are a frequent difficulty that teachers experience. Common complaints by teachers include vocal fatigue and hoarseness. One possible explanation for these symptoms is prolonged elevations in vocal loudness within the classroom. This investigation examined the effectiveness of sound-field frequency modulation (FM) amplification on reducing the sound pressure level (SPL) of the teacher's voice during classroom instruction. Specifically, SPL was examined during speech produced in a classroom lecture by 10 teachers with and without the use of sound-field amplification. Results indicated a significant 2.42-dB decrease in SPL with the use of sound-field FM amplification. These data support the use of sound-field amplification in the vocal hygiene regimen recommended to teachers by speech-language pathologists.
Estimating Subglottal Pressure from Neck-Surface Acceleration during Normal Voice Production
ERIC Educational Resources Information Center
Fryd, Amanda S.; Van Stan, Jarrad H.; Hillman, Robert E.; Mehta, Daryush D.
2016-01-01
Purpose: The purpose of this study was to evaluate the potential for estimating subglottal air pressure using a neck-surface accelerometer and to compare the accuracy of predicting subglottal air pressure relative to predicting acoustic sound pressure level (SPL). Method: Indirect estimates of subglottal pressure (P[subscript sg]') were obtained…
Evaluation of the Self-Stigma of Stuttering Scale (4S)
ERIC Educational Resources Information Center
Boyle, Michael P.
2013-01-01
Purpose: To create a psychometrically sound scale that measures different levels of internalized stigma (i.e., self-stigma) among adults who stutter and to analyze factor structure, reliability, and initial construct validity of the scale. Method: Two-hundred ninety-one adults who stutter were recruited from Board Recognized Specialists in Fluency…
Teachers' Perceptions of the Impact of the Jolly Phonics Program on Students' Literacy
ERIC Educational Resources Information Center
Moodie-Reid, Lorane
2016-01-01
At 2 primary schools in Western Jamaica, students at the Grade 1 level lacked basic literacy skills of comprehension, letter recognition, letter sounds, and oral communication. The purpose of this qualitative evaluation study was to investigate teachers' perceptions of the Jolly Phonics program implemented to improve students' literacy in Grades…
Tracking of "Moving" Fused Auditory Images by Children.
ERIC Educational Resources Information Center
Cranford, Jerry L.; And Others
1993-01-01
This study evaluated the ability of 30 normally developing children (ages 6-12) to report the perceived location of a stationary fused auditory image (FAI) or track a "moving" FAI. Although subjects performed at normal adult levels with the stationary sound measure, they exhibited a significant age-related trend with the moving sound…
ERIC Educational Resources Information Center
Flexer, Carol; Gans, Donald P.
1985-01-01
Responses to sound were observed in two groups of children (one developmentally normal, the other older but profoundly multihandicapped). Results showed no significant differences between groups. In both groups, however, responsiveness was dependent on hearing level and bandwidth but not on meaningfulness. Results support the practice of…
Ganta, Shravani; Nagaraj, Anup; Pareek, Sonia; Atri, Mansi; Singh, Kushpal; Sidiq, Mohsin
2014-01-01
Background: Noise is a source of pervasive occupational hazard for practicing dentists and the patients. The sources of dental sounds by various dental equipments can pose as a potential hazard to hearing system and add to the annoyance levels of the patients. The aim of the study was to analyze the noise levels from various equipments and evaluate the effect of acoustic noise stimulus on dental fear and annoyance levels among patients attending different dental clinic setups in Jaipur, India. Methodology: The sampling frame comprised of 180 patients, which included 90 patients attending 10 different private clinics and 90 patients attending a Dental College in Jaipur. The levels of Acoustic Noise Stimulus originating from different equipments were determined using a precision sound level meter/decibulometer. Dental fear among patients was measured using Dental Fear Scale (DFS). Results: Statistical analysis was performed using chi square test and unpaired t-test. The mean background noise levels were found to be maximum in the pre-clinical setup/ laboratory areas (69.23+2.20). Females and the patients attending dental college setup encountered more fear on seeing the drill as compared to the patients attending private clinics (p<0.001). Conclusion: The sources of dental sounds can pose as a potential hazard to hearing system. It was analyzed that the environment in the clinics can directly have an effect on the fear and annoyance levels of patients. Hence it is necessary control the noise from various dental equipments to reduce the fear of patients from visiting a dental clinic. PMID:24959512
Using Incremental Rehearsal to Teach Letter Sounds to English Language Learners
ERIC Educational Resources Information Center
Rahn, Naomi L.; Wilson, Jennifer; Egan, Andrea; Brandes, Dana; Kunkel, Amy; Peterson, Meredith; McComas, Jennifer
2015-01-01
This study examined the effects of incremental rehearsal (IR) on letter sound expression for one kindergarten and one first grade English learner who were below district benchmark for letter sound fluency. A single-subject multiple-baseline design across sets of unknown letter sounds was used to evaluate the effect of IR on letter-sound expression…
33 CFR 67.10-40 - Sound signals authorized for use prior to January 1, 1973.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., and 67.10-10, if the sound signal has a minimum sound pressure level as specified in Table A of... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Sound signals authorized for use... STRUCTURES General Requirements for Sound signals § 67.10-40 Sound signals authorized for use prior to...
Accuracy of assessing the level of impulse sound from distant sources.
Wszołek, Tadeusz; Kłaczyński, Maciej
2007-01-01
Impulse sound events are characterised by ultra high pressures and low frequencies. Lower frequency sounds are generally less attenuated over a given distance in the atmosphere than higher frequencies. Thus, impulse sounds can be heard over greater distances and will be more affected by the environment. To calculate a long-term average immission level it is necessary to apply weighting factors like the probability of the occurrence of each weather condition during the relevant time period. This means that when measuring impulse noise at a long distance it is necessary to follow environmental parameters in many points along the way sound travels and also to have a database of sound transfer functions in the long term. The paper analyses the uncertainty of immission measurement results of impulse sound from cladding and destroying explosive materials. The influence of environmental conditions on the way sound travels is the focus of this paper.
Validation of Aircraft Noise Prediction Models at Low Levels of Exposure
NASA Technical Reports Server (NTRS)
Page, Juliet A.; Hobbs, Christopher M.; Plotkin, Kenneth J.; Stusnick, Eric; Shepherd, Kevin P. (Technical Monitor)
2000-01-01
Aircraft noise measurements were made at Denver International Airport for a period of four weeks. Detailed operational information was provided by airline operators which enabled noise levels to be predicted using the FAA's Integrated Noise Model. Several thrust prediction techniques were evaluated. Measured sound exposure levels for departure operations were found to be 4 to 10 dB higher than predicted, depending on the thrust prediction technique employed. Differences between measured and predicted levels are shown to be related to atmospheric conditions present at the aircraft altitude.
[Evaluation of the risk on hearing loss at soldiers].
Konopka, Wiesław; Olszewski, Jurek; Straszyński, Piotr
2006-01-01
Noise produced by weapons may be harmful to soldiers during military service. Exposure to impulse noise during compulsory military service depends on the number of shots, explosion impulses, distance of injured ear from causal firearm as well as on the use of hearing protectors. Weapons produce impulse noises, which are characterized by peak pressure level and frequency. The purpose of this work was to calculate and estimate risk on hearing at soldiers during one year of the military service. The study comparised three groups of soldiers with different kind of exposure to noise divided according total noise exposure. In order to evaluate the amount of the exposure to impulse noise the total level of noise and the spectrum analysis were performed for all types of weapons, which were used during military service. The equivalent continuous A-weighted sound pressure level, L A eq, Te [dB], maximum A-weighted sound pressure level, L A max [dB] and C weighted peak sound pressure level, L C peak [dB] were measured. The highest total exposure to noise concerned group I (2222,9 kPa(2)/s for right ear and 22212,8 kPa(2)/s for left one) with total exposure time 248,3 minutes. In the II group estimated total exposure to noise was 611,8 kPa(2)/s for right ear and 743,6 kPa(2)/s for left one. In the III group least exposed to noise, estimated total exposure to noise was 103 kPa(2)/s for right ear and 109 kPa(2)/s for left one with total time exposure 17,8 minutes. Difference between groups is dependent on kind of military service. Estimated exposure to weapons noise may prevent soldiers before hearing loss. We did not notice differences between sites of ears.
Review: The use of bull breeding soundness evaluation to identify subfertile and infertile bulls.
Barth, A D
2018-06-01
Efficient and economical herd management depends a great deal on maintaining a short, well-defined calving season. This requires highly fertile females and bulls. Low pregnancy rates are very noticeable, however; potentially greater economic loss may be due to delayed conception. Many studies showed that approximately one of every five bulls had inadequate semen quality, physical soundness, or both, but when evaluation of serving capacity is included about one in four bulls is unsatisfactory. Due mainly to the time and expense that the market will bear, usually only physical soundness and semen quality are evaluated. Breeding soundness evaluation is a useful, low-cost screening method for reducing the risk of using low fertility bulls. The biggest problem with breeding soundness evaluations is not our lack of knowledge or ability, but in the willingness of veterinary schools to provide adequate equipment and training in this area, a lack of diagnostic laboratories equipped to handle the more difficult cases and, most importantly, the weaknesses of human nature that result in negligent testing procedure.
Hermannsen, Line; Beedholm, Kristian
2017-01-01
Acoustic harassment devices (AHD) or ‘seal scarers’ are used extensively, not only to deter seals from fisheries, but also as mitigation tools to deter marine mammals from potentially harmful sound sources, such as offshore pile driving. To test the effectiveness of AHDs, we conducted two studies with similar experimental set-ups on two key species: harbour porpoises and harbour seals. We exposed animals to 500 ms tone bursts at 12 kHz simulating that of an AHD (Lofitech), but with reduced output levels (source peak-to-peak level of 165 dB re 1 µPa). Animals were localized with a theodolite before, during and after sound exposures. In total, 12 sound exposures were conducted to porpoises and 13 exposures to seals. Porpoises were found to exhibit avoidance reactions out to ranges of 525 m from the sound source. Contrary to this, seal observations increased during sound exposure within 100 m of the loudspeaker. We thereby demonstrate that porpoises and seals respond very differently to AHD sounds. This has important implications for application of AHDs in multi-species habitats, as sound levels required to deter less sensitive species (seals) can lead to excessive and unwanted large deterrence ranges on more sensitive species (porpoises). PMID:28791155
The influence of sea ice, wind speed and marine mammals on Southern Ocean ambient sound
van Opzeeland, Ilse; Boebel, Olaf
2017-01-01
This paper describes the natural variability of ambient sound in the Southern Ocean, an acoustically pristine marine mammal habitat. Over a 3-year period, two autonomous recorders were moored along the Greenwich meridian to collect underwater passive acoustic data. Ambient sound levels were strongly affected by the annual variation of the sea-ice cover, which decouples local wind speed and sound levels during austral winter. With increasing sea-ice concentration, area and thickness, sound levels decreased while the contribution of distant sources increased. Marine mammal sounds formed a substantial part of the overall acoustic environment, comprising calls produced by Antarctic blue whales (Balaenoptera musculus intermedia), fin whales (Balaenoptera physalus), Antarctic minke whales (Balaenoptera bonaerensis) and leopard seals (Hydrurga leptonyx). The combined sound energy of a group or population vocalizing during extended periods contributed species-specific peaks to the ambient sound spectra. The temporal and spatial variation in the contribution of marine mammals to ambient sound suggests annual patterns in migration and behaviour. The Antarctic blue and fin whale contributions were loudest in austral autumn, whereas the Antarctic minke whale contribution was loudest during austral winter and repeatedly showed a diel pattern that coincided with the diel vertical migration of zooplankton. PMID:28280544
Why Do People Like Loud Sound? A Qualitative Study.
Welch, David; Fremaux, Guy
2017-08-11
Many people choose to expose themselves to potentially dangerous sounds such as loud music, either via speakers, personal audio systems, or at clubs. The Conditioning, Adaptation and Acculturation to Loud Music (CAALM) Model has proposed a theoretical basis for this behaviour. To compare the model to data, we interviewed a group of people who were either regular nightclub-goers or who controlled the sound levels in nightclubs (bar managers, musicians, DJs, and sound engineers) about loud sound. Results showed four main themes relating to the enjoyment of loud sound: arousal/excitement, facilitation of socialisation, masking of both external sound and unwanted thoughts, and an emphasis and enhancement of personal identity. Furthermore, an interesting incidental finding was that sound levels appeared to increase gradually over the course of the evening until they plateaued at approximately 97 dBA Leq around midnight. Consideration of the data generated by the analysis revealed a complex of influential factors that support people in wanting exposure to loud sound. Findings were considered in terms of the CAALM Model and could be explained in terms of its principles. From a health promotion perspective, the Social Ecological Model was applied to consider how the themes identified might influence behaviour. They were shown to influence people on multiple levels, providing a powerful system which health promotion approaches struggle to address.
NASA Astrophysics Data System (ADS)
Moore, Brian C. J.
Psychoacoustics
Salomons, Erik M; Janssen, Sabine A
2011-06-01
In environmental noise control one commonly employs the A-weighted sound level as an approximate measure of the effect of noise on people. A measure that is more closely related to direct human perception of noise is the loudness level. At constant A-weighted sound level, the loudness level of a noise signal varies considerably with the shape of the frequency spectrum of the noise signal. In particular the bandwidth of the spectrum has a large effect on the loudness level, due to the effect of critical bands in the human hearing system. The low-frequency content of the spectrum also has an effect on the loudness level. In this note the relation between loudness level and A-weighted sound level is analyzed for various environmental noise spectra, including spectra of traffic noise, aircraft noise, and industrial noise. From loudness levels calculated for these environmental noise spectra, diagrams are constructed that show the relation between loudness level, A-weighted sound level, and shape of the spectrum. The diagrams show that the upper limits of the loudness level for broadband environmental noise spectra are about 20 to 40 phon higher than the lower limits for narrowband spectra, which correspond to the loudness levels of pure tones. The diagrams are useful for assessing limitations and potential improvements of environmental noise control methods and policy based on A-weighted sound levels.
NASA Technical Reports Server (NTRS)
Koch, L. Danielle
2012-01-01
Fan inflow distortion tone noise has been studied computationally and experimentally. Data from two experiments in the NASA Glenn Advanced Noise Control Fan rig have been used to validate acoustic predictions. The inflow to the fan was distorted by cylindrical rods inserted radially into the inlet duct one rotor chord length upstream of the fan. The rods were arranged in both symmetric and asymmetric circumferential patterns. In-duct and farfield sound pressure level measurements were recorded. It was discovered that for positive circumferential modes, measured circumferential mode sound power levels in the exhaust duct were greater than those in the inlet duct and for negative circumferential modes, measured total circumferential mode sound power levels in the exhaust were less than those in the inlet. Predicted trends in overall sound power level were proven to be useful in identifying circumferentially asymmetric distortion patterns that reduce overall inlet distortion tone noise, as compared to symmetric arrangements of rods. Detailed comparisons between the measured and predicted radial mode sound power in the inlet and exhaust duct indicate limitations of the theory.
Christensen, Christian Bech; Christensen-Dalsgaard, Jakob; Brandt, Christian; Madsen, Peter Teglberg
2012-01-15
Snakes lack both an outer ear and a tympanic middle ear, which in most tetrapods provide impedance matching between the air and inner ear fluids and hence improve pressure hearing in air. Snakes would therefore be expected to have very poor pressure hearing and generally be insensitive to airborne sound, whereas the connection of the middle ear bone to the jaw bones in snakes should confer acute sensitivity to substrate vibrations. Some studies have nevertheless claimed that snakes are quite sensitive to both vibration and sound pressure. Here we test the two hypotheses that: (1) snakes are sensitive to sound pressure and (2) snakes are sensitive to vibrations, but cannot hear the sound pressure per se. Vibration and sound-pressure sensitivities were quantified by measuring brainstem evoked potentials in 11 royal pythons, Python regius. Vibrograms and audiograms showed greatest sensitivity at low frequencies of 80-160 Hz, with sensitivities of -54 dB re. 1 m s(-2) and 78 dB re. 20 μPa, respectively. To investigate whether pythons detect sound pressure or sound-induced head vibrations, we measured the sound-induced head vibrations in three dimensions when snakes were exposed to sound pressure at threshold levels. In general, head vibrations induced by threshold-level sound pressure were equal to or greater than those induced by threshold-level vibrations, and therefore sound-pressure sensitivity can be explained by sound-induced head vibration. From this we conclude that pythons, and possibly all snakes, lost effective pressure hearing with the complete reduction of a functional outer and middle ear, but have an acute vibration sensitivity that may be used for communication and detection of predators and prey.
Opponent Coding of Sound Location (Azimuth) in Planum Temporale is Robust to Sound-Level Variations
Derey, Kiki; Valente, Giancarlo; de Gelder, Beatrice; Formisano, Elia
2016-01-01
Coding of sound location in auditory cortex (AC) is only partially understood. Recent electrophysiological research suggests that neurons in mammalian auditory cortex are characterized by broad spatial tuning and a preference for the contralateral hemifield, that is, a nonuniform sampling of sound azimuth. Additionally, spatial selectivity decreases with increasing sound intensity. To accommodate these findings, it has been proposed that sound location is encoded by the integrated activity of neuronal populations with opposite hemifield tuning (“opponent channel model”). In this study, we investigated the validity of such a model in human AC with functional magnetic resonance imaging (fMRI) and a phase-encoding paradigm employing binaural stimuli recorded individually for each participant. In all subjects, we observed preferential fMRI responses to contralateral azimuth positions. Additionally, in most AC locations, spatial tuning was broad and not level invariant. We derived an opponent channel model of the fMRI responses by subtracting the activity of contralaterally tuned regions in bilateral planum temporale. This resulted in accurate decoding of sound azimuth location, which was unaffected by changes in sound level. Our data thus support opponent channel coding as a neural mechanism for representing acoustic azimuth in human AC. PMID:26545618
Kim, Gibbeum; Han, Woojae
2018-05-01
The present study estimated the sound pressure levels of various music genres at the volume steps that contemporary smartphones deliver, because these levels put the listener at potential risk for hearing loss. Using six different smartphones (Galaxy S6, Galaxy Note 3, iPhone 5S, iPhone 6, LG G2, and LG G3), the sound pressure levels for three genres of K-pop music (dance-pop, hip-hop, and pop-ballad) and a Billboard pop chart of assorted genres were measured through an earbud for the first risk volume that was at the risk sign proposed by the smartphones, as well as consecutive higher volumes using a sound level meter and artificial mastoid. The first risk volume step of the Galaxy S6 and the LG G2, among the six smartphones, had the significantly lowest (84.1 dBA) and highest output levels (92.4 dBA), respectively. As the volume step increased, so did the sound pressure levels. The iPhone 6 was loudest (113.1 dBA) at the maximum volume step. Of the music genres, dance-pop showed the highest output level (91.1 dBA) for all smartphones. Within the frequency range of 20~ 20,000 Hz, the sound pressure level peaked at 2000 Hz for all the smartphones. The results showed that the sound pressure levels of either the first volume step or the maximum volume step were not the same for the different smartphone models and genres of music, which means that the risk volume sign and its output levels should be unified across the devices for their users. In addition, the risk volume steps proposed by the latest smartphone models are high enough to cause noise-induced hearing loss if their users habitually listen to music at those levels.
Sound recordings of road maintenance equipment on the Lincoln National Forest, New Mexico
D. K. Delaney; T. G. Grubb
2004-01-01
The purpose of this pilot study was to record, characterize, and quantify road maintenance activity in Mexican spotted owl (Strix occidentalis lucida) habitat to gauge potential sound level exposure for owls during road maintenance activities. We measured sound levels from three different types of road maintenance equipment (rock crusherlloader,...
49 CFR Appendix D to Part 227 - Audiometric Test Rooms
Code of Federal Regulations, 2011 CFR
2011-10-01
... sound pressure levels exceeding those in Table D-1 when measured by equipment conforming at least to the..._regulations/ibr_locations.html. Table D-1—Maximum Allowable Octave-Band Sound Pressure Levels for Audiometric Test Rooms Octave-band center frequency (Hz) 500 1000 2000 4000 8000 Sound pressure levels—supra-aural...
49 CFR Appendix D to Part 227 - Audiometric Test Rooms
Code of Federal Regulations, 2010 CFR
2010-10-01
... sound pressure levels exceeding those in Table D-1 when measured by equipment conforming at least to the..._regulations/ibr_locations.html. Table D-1—Maximum Allowable Octave-Band Sound Pressure Levels for Audiometric Test Rooms Octave-band center frequency (Hz) 500 1000 2000 4000 8000 Sound pressure levels—supra-aural...
[Acoustic conditions in open plan office - Application of technical measures in a typical room].
Mikulski, Witold
2018-03-09
Noise in open plan offices should not exceed acceptable levels for the hearing protection. Its major negative effects on employees are nuisance and impediment in execution of work. Specific technical solutions should be introduced to provide proper acoustic conditions for work performance. Acoustic evaluation of a typical open plan office was presented in the article published in "Medycyna Pracy" 5/2016. None of the rooms meets all the criteria, therefore, in this article one of the rooms was chosen to apply different technical solutions to check the possibility of reaching proper acoustic conditions. Acoustic effectiveness of those solutions was verified by means of digital simulation. The model was checked by comparing the results of measurements and calculations before using simulation. The analyzis revealed that open plan offices supplemented with signals for masking speech signals can meet all the required criteria. It is relatively easy to reach proper reverberation time (i.e., sound absorption). It is more difficult to reach proper values of evaluation parameters determined from A-weighted sound pressure level (SPLA) of speech. The most difficult is to provide proper values of evaluation parameters determined from speech transmission index (STI). Finally, it is necessary (besides acoustic treatment) to use devices for speech masking. The study proved that it is technically possible to reach proper acoustic condition. Main causes of employees complaints in open plan office are inadequate acoustic work conditions. Therefore, it is necessary to apply specific technical solutions - not only sound absorbing suspended ceiling and high acoustic barriers, but also devices for speech masking. Med Pr 2018;69(2):153-165. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.
Characterising the ambient sound environment for infants in intensive care wards.
Shoemark, Helen; Harcourt, Edward; Arnup, Sarah J; Hunt, Rod W
2016-04-01
The purpose of this study is to characterise ambient sound levels of paediatric and neonatal intensive care units in an old and new hospital according to current standards. The sound environment was surveyed for 24-h data collection periods (n = 80) in the Neonatal and Paediatric Intensive Care Units (NICUs and PICUs) and Special Care Nursery of the old and new Royal Children's Hospital Melbourne. The ambient sound environment was characterised as the proportion of time the ongoing ambient sound met standard benchmarks, the mean 5-s sound levels and the number and duration of noise events. In the old hospital, none of the data collection periods in the NICU and PICU met the standard benchmark for ongoing ambient sound, while only 5 of the 22 data collection periods in the new hospital met the recommended level. There was no change in proportion of time at recommended Leq between the old and the new Special Care Nursery. There was strong evidence for a difference in the mean number of events >65 dBA (Lmax ) in the old and new hospital (rate ratio = 0.82, 95% confidence interval: 0.73 to 0.92, P = 0.001). The NICU and PICU were above 50 dBA in 75% of all data collection periods, with ventilatory equipment associated with higher ongoing ambient sound levels. The ongoing ambient sound suggests that the background sound environment of the new hospital is not different to the old hospital. However, there may be a reduction in the number of noise events. © 2016 The Authors Journal of Paediatrics and Child Health © 2016 Paediatrics and Child Health Division (Royal Australasian College of Physicians).
Pedley, Adam J; Kitterick, Pádraig T
2017-09-01
Contra-lateral routing of signals (CROS) devices re-route sound between the deaf and hearing ears of unilaterally-deaf individuals. This rerouting would be expected to disrupt access to monaural level cues that can support monaural localisation in the horizontal plane. However, such a detrimental effect has not been confirmed by clinical studies of CROS use. The present study aimed to exercise strict experimental control over the availability of monaural cues to localisation in the horizontal plane and the fitting of the CROS device to assess whether signal routing can impair the ability to locate sources of sound and, if so, whether CROS selectively disrupts monaural level or spectral cues to horizontal location, or both. Unilateral deafness and CROS device use were simulated in twelve normal hearing participants. Monaural recordings of broadband white noise presented from three spatial locations (-60°, 0°, and +60°) were made in the ear canal of a model listener using a probe microphone with and without a CROS device. The recordings were presented to participants via an insert earphone placed in their right ear. The recordings were processed to disrupt either monaural level or spectral cues to horizontal sound location by roving presentation level or the energy across adjacent frequency bands, respectively. Localisation ability was assessed using a three-alternative forced-choice spatial discrimination task. Participants localised above chance levels in all conditions. Spatial discrimination accuracy was poorer when participants only had access to monaural spectral cues compared to when monaural level cues were available. CROS use impaired localisation significantly regardless of whether level or spectral cues were available. For both cues, signal re-routing had a detrimental effect on the ability to localise sounds originating from the side of the deaf ear (-60°). CROS use also impaired the ability to use level cues to localise sounds originating from straight ahead (0°). The re-routing of sounds can restrict access to the monaural cues that provide a basis for determining sound location in the horizontal plane. Perhaps encouragingly, the results suggest that both monaural level and spectral cues may not be disrupted entirely by signal re-routing and that it may still be possible to reliably identify sounds originating on the hearing side. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Sound quality assessment of Diesel combustion noise using in-cylinder pressure components
NASA Astrophysics Data System (ADS)
Payri, F.; Broatch, A.; Margot, X.; Monelletta, L.
2009-01-01
The combustion process in direct injection (DI) Diesel engines is an important source of noise, and it is thus the main reason why end-users could be reluctant to drive vehicles powered with this type of engine. This means that the great potential of Diesel engines for environment preservation—due to their lower consumption and the subsequent reduction of CO2 emissions—may be lost. Moreover, the advanced combustion concepts—e.g. the HCCI (homogeneous charge compression ignition)—developed to comply with forthcoming emissions legislation, while maintaining the efficiency of current engines, are expected to be noisier because they are characterized by a higher amount of premixed combustion. For this reason many efforts have been dedicated by car manufacturers in recent years to reduce the overall level and improve the sound quality of engine noise. Evaluation procedures are required, both for noise levels and sound quality, that may be integrated in the global engine development process in a timely and cost-effective manner. In previous published work, the authors proposed a novel method for the assessment of engine noise level. A similar procedure is applied in this paper to demonstrate the suitability of combustion indicators for the evaluation of engine noise quality. These indicators, which are representative of the peak velocity of fuel burning and the resonance in the combustion chamber, are well correlated with the combustion noise mark obtained from jury testing. Quite good accuracy in the prediction of the engine noise quality has been obtained with the definition of a two-component regression, which also permits the identification of the combustion process features related to the resulting noise quality, so that corrective actions may be proposed.
Landrau-Giovannetti, Nelmarie; Mignucci-Giannoni, Antonio A; Reidenberg, Joy S
2014-10-01
West Indian (Trichechus manatus) and Amazonian (T. inunguis) manatees are vocal mammals, with most sounds produced for communication between mothers and calves. While their hearing and vocalizations have been well studied, the actual mechanism of sound production is unknown. Acoustical recordings and anatomical examination were used to determine the source of sound generation. Recordings were performed on live captive manatees from Puerto Rico, Cuba and Colombia (T. manatus) and from Peru (T. inunguis) to determine focal points of sound production. The manatees were recorded using two directional hydrophones placed on the throat and nasal region and an Edirol-R44 digital recorder. The average sound intensity level was analyzed to evaluate the sound source with a T test: paired two sample for means. Anatomical examinations were conducted on six T. manatus carcasses from Florida and Puerto Rico. During necropsies, the larynx, trachea, and nasal areas were dissected, with particular focus on identifying musculature and soft tissues capable of vibrating or constricting the airway. From the recordings we found that the acoustical intensity was significant (P < 0.0001) for both the individuals and the pooled manatees in the ventral throat region compared to the nasal region. From the dissection we found two raised areas of tissue in the lateral walls of the manatee's laryngeal lumen that are consistent with mammalian vocal folds. They oppose each other and may be able to regulate airflow between them when they are adducted or abducted by muscular control of arytenoid cartilages. Acoustic and anatomical evidence taken together suggest vocal folds as the mechanism for sound production in manatees. © 2014 Wiley Periodicals, Inc.
Noise Reduction Of Air Blower Casing Using Composites
NASA Astrophysics Data System (ADS)
Kolla*, S.; Kumar, Y. Anil; Rajesh, S.
Sound subjectively, what is heard by the ear; objectively, is a mecha nical disturbance from equilibrium in an elastic medium. The noise produced by a rotating component has two main components, the broadband noise and the discrete frequency noise. The broadband noise from a rotor is due to random loading forces on the blades, which are induced by the absorption of atmospheric turbulence. The discrete frequency noise is due to periodic interaction of incoming air with the blades of the rotor. At present the centrifugal blowers, in Naval defense application which is made of steel is generating a noise of 86dB, which causes mental imbalance to the people working near the blower on ship. Therefore in Naval defense applications the reduction of sound level from a source is very important and critical task. Hence the objective of this paper is to reduce the noise level produced by the metal air blower. The noise radiated by the casing of a centrifugal blower can be effectively reduced by the use of (1) Composite Materials, (2) Visco-Elastic material treatment and (3) Stiffness addition. In this paper it is proposed to carry out a study to evaluate the effectiveness of composites in reducing noise levels of the casing. Composite materials are those containing more than one bonded material, each with different struc tural properties. The advantage of composite materials is the potential for a high ratio of stiffness to weight. In order to evaluate the effectiveness of composites over metals, modal analysis (Eigen value analysis) and Static analysis was performed on both composite and metal blowers using FEA package (ANSYS). Modal analysis is performed on both metals (Alluminium and Composite) blower casing to find out the first ten natural frequencies and static analysis is performed for a pressure of 1570 Pa. This paper also describes the experimental setup of the centrifugal blower, the values of the sound levels for both metal and FRP blowers are taken at a distance of 1m from inlet of the blower, and the sound pressure values at different frequencies of both metal and composite blower were compared. This paper also describes numerical approach using SYSNOISE software. Fluid medium, boundary condition and the type of analysis was defined. A boundary mesh of sphere shaped with a radius of 1m was created and a known source was given as input in order to get the sound pressure levels for different frequencies at the boundary mesh. With blower as the noise source and noise that is radiated exterior to the casing is then estimated at various points of interest and the results were correlated with experimental data.
Knobel, Keila Alessandra Baraldi; Lima, Maria Cecília Marconi Pinheiro
2014-01-01
Exposure to loud sound during leisure activities for long periods of time is an important area to implement preventive health education, especially among young people. The aim was to identify the relations among awareness about the damaging effects of loud levels of sounds, previous exposures do loud sounds, preferences-related to sound levels and knowledge about hearing protection with age, gender, and their parent's educational level among children. Prospective cross-sectional. Seven hundred and forty students (5-16 years old) and 610 parents participated in the study. Chi-square test, Fisher exact test and linear regression. About 86.5% of the children consider that loud sounds damage the ears and 53.7% dislike noisy places. Children were previously exposed to parties and concerts with loud music, Mardi Gras, firecrackers and loud music at home or in the car and loud music with earphones. About 18.4% of the younger children could select the volume of the music, versus 65.3% of the older ones. Children have poor information about hearing protection and do not have hearing protection device. Knowledge about the risks related to exposures to loud sounds and about strategies to protect their hearing increases with age, but preference for loud sounds and exposures to it increases too. Gender and parents' instructional level have little influence on the studied variables. Many of the children's recreational activities are noisy. It is possible that the tendency of increasing preference for loud sounds with age might be a result of a learned behavior.
Chao, Chun-Tang; Maneetien, Nopadon; Wang, Chi-Jo; Chiou, Juing-Shian
2014-01-01
This paper presents the design and evaluation of the hardware circuit for electronic stethoscopes with heart sound cancellation capabilities using field programmable gate arrays (FPGAs). The adaptive line enhancer (ALE) was adopted as the filtering methodology to reduce heart sound attributes from the breath sounds obtained via the electronic stethoscope pickup. FPGAs were utilized to implement the ALE functions in hardware to achieve near real-time breath sound processing. We believe that such an implementation is unprecedented and crucial toward a truly useful, standalone medical device in outpatient clinic settings. The implementation evaluation with one Altera cyclone II-EP2C70F89 shows that the proposed ALE used 45% resources of the chip. Experiments with the proposed prototype were made using DE2-70 emulation board with recorded body signals obtained from online medical archives. Clear suppressions were observed in our experiments from both the frequency domain and time domain perspectives.
Sanchez, Tanit Ganz; Moraes, Fernanda; Casseb, Juliana; Cota, Jaci; Freire, Katya; Roberts, Larry E.
2016-01-01
Recent neuroscience research suggests that tinnitus may reflect synaptic loss in the cochlea that does not express in the audiogram but leads to neural changes in auditory pathways that reduce sound level tolerance (SLT). Adolescents (N = 170) completed a questionnaire addressing their prior experience with tinnitus, potentially risky listening habits, and sensitivity to ordinary sounds, followed by psychoacoustic measurements in a sound booth. Among all adolescents 54.7% reported by questionnaire that they had previously experienced tinnitus, while 28.8% heard tinnitus in the booth. Psychoacoustic properties of tinnitus measured in the sound booth corresponded with those of chronic adult tinnitus sufferers. Neither hearing thresholds (≤15 dB HL to 16 kHz) nor otoacoustic emissions discriminated between adolescents reporting or not reporting tinnitus in the sound booth, but loudness discomfort levels (a psychoacoustic measure of SLT) did so, averaging 11.3 dB lower in adolescents experiencing tinnitus in the acoustic chamber. Although risky listening habits were near universal, the teenagers experiencing tinnitus and reduced SLT tended to be more protective of their hearing. Tinnitus and reduced SLT could be early indications of a vulnerability to hidden synaptic injury that is prevalent among adolescents and expressed following exposure to high level environmental sounds. PMID:27265722
Kosała, Krzysztof; Stępień, Bartłomiej
2016-01-01
This paper presents the verification of two partial indices proposed for the evaluation of continuous and impulse noise pollution in quarries. These indices, together with the sound power of machines index and the noise hazard index at the workstation, are components of the global index of assessment of noise hazard in the working environment of a quarry. This paper shows the results of acoustic tests carried out in an andesite quarry. Noise generated by machines and from performed blasting works was investigated. On the basis of acoustic measurements carried out in real conditions, the sound power levels of machines and the phenomenon of explosion were determined and, based on the results, three-dimensional models of acoustic noise propagation in the quarry were developed. To assess the degree of noise pollution in the area of the quarry, the continuous and impulse noise indices were used.
Khodr, Zeina G.; Sak, Mark A.; Pfeiffer, Ruth M.; Duric, Nebojsa; Littrup, Peter; Bey-Knight, Lisa; Ali, Haythem; Vallieres, Patricia; Sherman, Mark E.; Gierach, Gretchen L.
2015-01-01
Purpose: High breast density, as measured by mammography, is associated with increased breast cancer risk, but standard methods of assessment have limitations including 2D representation of breast tissue, distortion due to breast compression, and use of ionizing radiation. Ultrasound tomography (UST) is a novel imaging method that averts these limitations and uses sound speed measures rather than x-ray imaging to estimate breast density. The authors evaluated the reproducibility of measures of speed of sound and changes in this parameter using UST. Methods: One experienced and five newly trained raters measured sound speed in serial UST scans for 22 women (two scans per person) to assess inter-rater reliability. Intrarater reliability was assessed for four raters. A random effects model was used to calculate the percent variation in sound speed and change in sound speed attributable to subject, scan, rater, and repeat reads. The authors estimated the intraclass correlation coefficients (ICCs) for these measures based on data from the authors’ experienced rater. Results: Median (range) time between baseline and follow-up UST scans was five (1–13) months. Contributions of factors to sound speed variance were differences between subjects (86.0%), baseline versus follow-up scans (7.5%), inter-rater evaluations (1.1%), and intrarater reproducibility (∼0%). When evaluating change in sound speed between scans, 2.7% and ∼0% of variation were attributed to inter- and intrarater variation, respectively. For the experienced rater’s repeat reads, agreement for sound speed was excellent (ICC = 93.4%) and for change in sound speed substantial (ICC = 70.4%), indicating very good reproducibility of these measures. Conclusions: UST provided highly reproducible sound speed measurements, which reflect breast density, suggesting that UST has utility in sensitively assessing change in density. PMID:26429241
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khodr, Zeina G.; Pfeiffer, Ruth M.; Gierach, Gretchen L., E-mail: GierachG@mail.nih.gov
Purpose: High breast density, as measured by mammography, is associated with increased breast cancer risk, but standard methods of assessment have limitations including 2D representation of breast tissue, distortion due to breast compression, and use of ionizing radiation. Ultrasound tomography (UST) is a novel imaging method that averts these limitations and uses sound speed measures rather than x-ray imaging to estimate breast density. The authors evaluated the reproducibility of measures of speed of sound and changes in this parameter using UST. Methods: One experienced and five newly trained raters measured sound speed in serial UST scans for 22 women (twomore » scans per person) to assess inter-rater reliability. Intrarater reliability was assessed for four raters. A random effects model was used to calculate the percent variation in sound speed and change in sound speed attributable to subject, scan, rater, and repeat reads. The authors estimated the intraclass correlation coefficients (ICCs) for these measures based on data from the authors’ experienced rater. Results: Median (range) time between baseline and follow-up UST scans was five (1–13) months. Contributions of factors to sound speed variance were differences between subjects (86.0%), baseline versus follow-up scans (7.5%), inter-rater evaluations (1.1%), and intrarater reproducibility (∼0%). When evaluating change in sound speed between scans, 2.7% and ∼0% of variation were attributed to inter- and intrarater variation, respectively. For the experienced rater’s repeat reads, agreement for sound speed was excellent (ICC = 93.4%) and for change in sound speed substantial (ICC = 70.4%), indicating very good reproducibility of these measures. Conclusions: UST provided highly reproducible sound speed measurements, which reflect breast density, suggesting that UST has utility in sensitively assessing change in density.« less
Measor, Kevin R; Leavell, Brian C; Brewton, Dustin H; Rumschlag, Jeffrey; Barber, Jesse R; Razak, Khaleel A
2017-01-01
In active sensing, animals make motor adjustments to match sensory inputs to specialized neural circuitry. Here, we describe an active sensing system for sound level processing. The pallid bat uses downward frequency-modulated (FM) sweeps as echolocation calls for general orientation and obstacle avoidance. The bat's auditory cortex contains a region selective for these FM sweeps (FM sweep-selective region, FMSR). We show that the vast majority of FMSR neurons are sensitive and strongly selective for relatively low levels (30-60 dB SPL). Behavioral testing shows that when a flying bat approaches a target, it reduces output call levels to keep echo levels between ∼30 and 55 dB SPL. Thus, the pallid bat behaviorally matches echo levels to an optimized neural representation of sound levels. FMSR neurons are more selective for sound levels of FM sweeps than tones, suggesting that across-frequency integration enhances level tuning. Level-dependent timing of high-frequency sideband inhibition in the receptive field shapes increased level selectivity for FM sweeps. Together with previous studies, these data indicate that the same receptive field properties shape multiple filters (sweep direction, rate, and level) for FM sweeps, a sound common in multiple vocalizations, including human speech. The matched behavioral and neural adaptations for low-intensity echolocation in the pallid bat will facilitate foraging with reduced probability of acoustic detection by prey.
Measor, Kevin R.; Leavell, Brian C.; Brewton, Dustin H.; Rumschlag, Jeffrey; Barber, Jesse R.
2017-01-01
Abstract In active sensing, animals make motor adjustments to match sensory inputs to specialized neural circuitry. Here, we describe an active sensing system for sound level processing. The pallid bat uses downward frequency-modulated (FM) sweeps as echolocation calls for general orientation and obstacle avoidance. The bat’s auditory cortex contains a region selective for these FM sweeps (FM sweep-selective region, FMSR). We show that the vast majority of FMSR neurons are sensitive and strongly selective for relatively low levels (30-60 dB SPL). Behavioral testing shows that when a flying bat approaches a target, it reduces output call levels to keep echo levels between ∼30 and 55 dB SPL. Thus, the pallid bat behaviorally matches echo levels to an optimized neural representation of sound levels. FMSR neurons are more selective for sound levels of FM sweeps than tones, suggesting that across-frequency integration enhances level tuning. Level-dependent timing of high-frequency sideband inhibition in the receptive field shapes increased level selectivity for FM sweeps. Together with previous studies, these data indicate that the same receptive field properties shape multiple filters (sweep direction, rate, and level) for FM sweeps, a sound common in multiple vocalizations, including human speech. The matched behavioral and neural adaptations for low-intensity echolocation in the pallid bat will facilitate foraging with reduced probability of acoustic detection by prey. PMID:28275715
[Acoustic conditions in open plan offices - Pilot test results].
Mikulski, Witold
The main source of noise in open plan office are conversations. Office work standards in such premises are attained by applying specific acoustic adaptation. This article presents the results of pilot tests and acoustic evaluation of open space rooms. Acoustic properties of 6 open plan office rooms were the subject of the tests. Evaluation parameters, measurement methods and criterial values were adopted according to the following standards: PN-EN ISO 3382- 3:2012, PN-EN ISO 3382-2:2010, PN-B-02151-4:2015-06 and PN-B-02151-3:2015-10. The reverberation time was 0.33- 0.55 s (maximum permissible value in offices - 0.6 s; the criterion was met), sound absorption coefficient in relation to 1 m2 of the room's plan was 0.77-1.58 m2 (minimum permissible value - 1.1 m2; 2 out of 6 rooms met the criterion), distraction distance was 8.5-14 m (maximum permissible value - 5 m; none of the rooms met the criterion), A-weighted sound pressure level of speech at a distance of 4 m was 43.8-54.7 dB (maximum permissible value - 48 dB; 2 out of 6 rooms met the criterion), spatial decay rate of the speech was 1.8-6.3 dB (minimum permissible value - 7 dB; none of the rooms met the criterion). Standard acoustic treatment, containing sound absorbing suspended ceiling, sound absorbing materials on the walls, carpet flooring and sound absorbing workplace barriers, is not sufficient. These rooms require specific advanced acoustic solutions. Med Pr 2016;67(5):653-662. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.
Di, Guo-Qing; Lin, Qi-Li; Li, Zheng-Guang; Kang, Jian
2014-03-07
High-speed railway (HR, Electrified railway with service speed above 200 km/h.) noise and conventional railway (CR, Electrified railway with service speed under 200 km/h.) noise are different in both time and frequency domain. There is an urgent need to study the influence of HR noise and consequently, develop appropriate noise evaluation index and limits for the total railway noise including HR and CR noise. Based on binaural recording of HR and CR noises in a approximate semi-free field, noise annoyance and activity disturbance induced by maximal train pass-by events in China were investigated through laboratory subjective evaluation. 80 students within recruited 102 students, 40 males and 40 females, 23.9 ± 2.1 years old, were finally selected as the subjects. After receiving noise stimulus via headphone of a binaural audio playback system, subjects were asked to express the annoyance or activity disturbance due to railway noise at a 0-100 numerical scale. The results show that with the same annoyance rating (A) or activity disturbance rating (D), the A-weighted equivalent sound pressure level (LAeq) of CR noise is approximately 7 dB higher than that of HR noise. Linear regression analysis between some acoustical parameters and A (or D) suggests that the coefficient of determination (R2) is higher with the instantaneous fast A-weighted sound pressure level (LAFmax) than that with LAeq. A combined acoustical parameter, LHC = 1.74LAFmax + 0.008LAFmax(Lp-LAeq), where Lp is the sound pressure level, was derived consequently, which could better evaluate the total railway noise, including HR and CR noise. More importantly, with a given LHC, the noise annoyance of HR and CR noise is the same. Among various acoustical parameters including LHC and LAeq, A and D have the highest correlation with LHC. LHC has been proved to be an appropriate index to evaluate the total railway noise, including both HR and CR. However, it should be pointed out that this study provides suggestive evidence, rather than a final proof. Further study is expected to elucidate conclusions above by additional measurements.
ERIC Educational Resources Information Center
McLeod, Sharynne; Baker, Elise; McCormack, Jane; Wren, Yvonne; Roulstone, Sue; Crowe, Kathryn; Masso, Sarah; White, Paul; Howland, Charlotte
2017-01-01
Purpose: The aim was to evaluate the effectiveness of computer-assisted input-based intervention for children with speech sound disorders (SSD). Method: The Sound Start Study was a cluster-randomized controlled trial. Seventy-nine early childhood centers were invited to participate, 45 were recruited, and 1,205 parents and educators of 4- and…
Sound Levels in East Texas Schools.
ERIC Educational Resources Information Center
Turner, Aaron Lynn
A survey of sound levels was taken in several Texas schools to determine the amount of noise and sound present by size of class, type of activity, location of building, and the presence of air conditioning and large amounts of glass. The data indicate that class size and relative amounts of glass have no significant bearing on the production of…
Kim, Jaehwan; Lim, Changwoo; Hong, Jiyoung; Lee, Soogab
2010-02-01
An experimental study was performed to compare the annoyances from civil-aircraft noise, military-aircraft noise, railway noise, and road-traffic noise. Two-way within-subjects designs were applied in this research. Fifty-two subjects, who were naive listeners, were given various stimuli with varying levels through a headphone in an anechoic chamber. Regardless of the frequency weighting network, even under the same average energy level, civil-aircraft noise was the most annoying, followed by military-aircraft noise, railway noise, and road-traffic noise. In particular, penalties in the time-averaged, A-weighted sound level (TAL) of about 8, 5, and 5 dB, respectively, were found in the civil-aircraft, military-aircraft, and railway noises. The reason could be clarified through the high-frequency component and the variability in the level. When people were exposed to sounds with the same maximum A-weighted level, a railway bonus of about 3 dB was found. However, transportation noise has been evaluated by the time-averaged A-weighted level in most countries. Therefore, in the present situation, the railway bonus is not acceptable for railway vehicles with diesel-electric engines.
The influence of the level formants on the perception of synthetic vowel sounds
NASA Astrophysics Data System (ADS)
Kubzdela, Henryk; Owsianny, Mariuz
A computer model of a generator of periodic complex sounds simulating consonants was developed. The system makes possible independent regulation of the level of each of the formants and instant generation of the sound. A trapezoid approximates the curve of the spectrum within the range of the formant. In using this model, each person in a group of six listeners experimentally selected synthesis parameters for six sounds that to him seemed optimal approximations of Polish consonants. From these, another six sounds were selected that were identified by a majority of the six persons and several additional listeners as being best qualified to serve as prototypes of Polish consonants. These prototypes were then used to randomly create sounds with various combinations at the level of the second and third formant and these were presented to seven listeners for identification. The results of the identifications are presented in table form in three variants and are described from the point of view of the requirements of automatic recognition of consonants in continuous speech.
Mitigation of Sri Lanka Island Effects in Colombo Sounding Data during DYNAMO
NASA Astrophysics Data System (ADS)
Ciesielski, P. E.; Johnson, R. H.; Yoneyama, K.
2013-12-01
During the Dynamics of the MJO (DYNAMO) field campaign, upper-air soundings were launched at Colombo, Sri Lanka as part of the enhanced northern sounding array (NSA) of the experiment. The Colombo soundings were affected at low-levels by diurnal heating of this large island and by flow blocking due to elevated terrain to the east of the Colombo site. Because of the large spacing between sounding sites, these small-scale effects are aliased onto the larger scale impacting analyses and atmospheric budgets over the DYNAMO NSA. To mitigate these local island effects on the large-scale budgets, a procedure was designed which uses ECMWF-analyzed fields in the vicinity of Sri Lanka to estimate open-ocean conditions (i.e, as if this island were not present). These 'unperturbed' ECMWF fields at low-levels are then merged with observed Colombo soundings. This procedure effectively mutes the blocking effects and large diurnal cycle observed in the low-level Colombo fields. In westerly flow regimes, adjusted Colombo winds increase the low-level westerlies by 2-3 m/s with a similar increase of the low-level easterlies in easterly flow regimes. In general, over the NSA the impact of the adjusted Colombo winds results in more low-level divergence (convergence), more mid-level subsidence (rising motion) and reduced (increased) rainfall during the westerly (easterly) wind regimes. In comparison to independent TRMM rainfall estimates, both the mean budget-derived rainfall and its temporal correlation are improved by using the adjusted Colombo soundings. In addition, use of the 'unperturbed' fields result in a more realistic moisture budget analyses, both in its diurnal cycle and during the build-up phase of the November MJO when a gradual deepening of apparent drying was observed. Overall, use of the adjusted Colombo soundings appears to have a beneficial impact on the NSA analyses and budgets.
Why Do People Like Loud Sound? A Qualitative Study
Welch, David; Fremaux, Guy
2017-01-01
Many people choose to expose themselves to potentially dangerous sounds such as loud music, either via speakers, personal audio systems, or at clubs. The Conditioning, Adaptation and Acculturation to Loud Music (CAALM) Model has proposed a theoretical basis for this behaviour. To compare the model to data, we interviewed a group of people who were either regular nightclub-goers or who controlled the sound levels in nightclubs (bar managers, musicians, DJs, and sound engineers) about loud sound. Results showed four main themes relating to the enjoyment of loud sound: arousal/excitement, facilitation of socialisation, masking of both external sound and unwanted thoughts, and an emphasis and enhancement of personal identity. Furthermore, an interesting incidental finding was that sound levels appeared to increase gradually over the course of the evening until they plateaued at approximately 97 dBA Leq around midnight. Consideration of the data generated by the analysis revealed a complex of influential factors that support people in wanting exposure to loud sound. Findings were considered in terms of the CAALM Model and could be explained in terms of its principles. From a health promotion perspective, the Social Ecological Model was applied to consider how the themes identified might influence behaviour. They were shown to influence people on multiple levels, providing a powerful system which health promotion approaches struggle to address. PMID:28800097
Liu, Juan; Ando, Hiroshi
2016-01-01
Most real-world events stimulate multiple sensory modalities simultaneously. Usually, the stiffness of an object is perceived haptically. However, auditory signals also contain stiffness-related information, and people can form impressions of stiffness from the different impact sounds of metal, wood, or glass. To understand whether there is any interaction between auditory and haptic stiffness perception, and if so, whether the inferred material category is the most relevant auditory information, we conducted experiments using a force-feedback device and the modal synthesis method to present haptic stimuli and impact sound in accordance with participants’ actions, and to modulate low-level acoustic parameters, i.e., frequency and damping, without changing the inferred material categories of sound sources. We found that metal sounds consistently induced an impression of stiffer surfaces than did drum sounds in the audio-only condition, but participants haptically perceived surfaces with modulated metal sounds as significantly softer than the same surfaces with modulated drum sounds, which directly opposes the impression induced by these sounds alone. This result indicates that, although the inferred material category is strongly associated with audio-only stiffness perception, low-level acoustic parameters, especially damping, are more tightly integrated with haptic signals than the material category is. Frequency played an important role in both audio-only and audio-haptic conditions. Our study provides evidence that auditory information influences stiffness perception differently in unisensory and multisensory tasks. Furthermore, the data demonstrated that sounds with higher frequency and/or shorter decay time tended to be judged as stiffer, and contact sounds of stiff objects had no effect on the haptic perception of soft surfaces. We argue that the intrinsic physical relationship between object stiffness and acoustic parameters may be applied as prior knowledge to achieve robust estimation of stiffness in multisensory perception. PMID:27902718
Evaluation of small arms noise in a natural soundscape-Bear Butte, SD
NASA Astrophysics Data System (ADS)
Braslau, David
2005-09-01
Most studies on soundscape intrusion have been limited to moving sources. Of less concern is noise from small arms. Potential impact was predicted from a proposed large small arms facility with 10
Evaluating a linearized Euler equations model for strong turbulence effects on sound propagation.
Ehrhardt, Loïc; Cheinet, Sylvain; Juvé, Daniel; Blanc-Benon, Philippe
2013-04-01
Sound propagation outdoors is strongly affected by atmospheric turbulence. Under strongly perturbed conditions or long propagation paths, the sound fluctuations reach their asymptotic behavior, e.g., the intensity variance progressively saturates. The present study evaluates the ability of a numerical propagation model based on the finite-difference time-domain solving of the linearized Euler equations in quantitatively reproducing the wave statistics under strong and saturated intensity fluctuations. It is the continuation of a previous study where weak intensity fluctuations were considered. The numerical propagation model is presented and tested with two-dimensional harmonic sound propagation over long paths and strong atmospheric perturbations. The results are compared to quantitative theoretical or numerical predictions available on the wave statistics, including the log-amplitude variance and the probability density functions of the complex acoustic pressure. The match is excellent for the evaluated source frequencies and all sound fluctuations strengths. Hence, this model captures these many aspects of strong atmospheric turbulence effects on sound propagation. Finally, the model results for the intensity probability density function are compared with a standard fit by a generalized gamma function.
Noise in contemporary neonatal intensive care.
Williams, Amber L; van Drongelen, Wim; Lasky, Robert E
2007-05-01
Weekly sound surveys (n = 63) were collected, using 5 s sampling intervals, for two modern neonatal intensive care units (NICUs). Median weekly equivalent sound pressure levels (LEQ) for NICU A ranged from 61 to 63 dB (A weighted), depending on the level of care. NICU B L(EQ) measurements ranged from 55 to 60 dB (A weighted). NICU B was recently built with a focus on sound abatement, explaining much of the difference between the two NICUs. Sound levels exceeded 45 dB (A weighted), recommended by the American Academy of Pediatrics, more than 70% of the time for all levels of care. Hourly L(EQ)s below 50 dB (A weighted) and hourly L10s below 55 dB (A weighted), recommended by the Sound Study Group (SSG) of the National Resource Center, were also exceeded in more than 70% of recorded samples. A third SSG recommendation, that the 1 s L(MAX), should not exceed 70 dB (A weighted), was exceeded relatively infrequently (< 11% of the time). Peak impulse measurements exceeded 90 dB for 6.3% of 5 s samples recorded from NICU A and 2.8% of NICU B samples. Twenty-four h periodicities in sound levels as a function of regular staff activities were apparent, but short-term variability was considerable.
Opponent Coding of Sound Location (Azimuth) in Planum Temporale is Robust to Sound-Level Variations.
Derey, Kiki; Valente, Giancarlo; de Gelder, Beatrice; Formisano, Elia
2016-01-01
Coding of sound location in auditory cortex (AC) is only partially understood. Recent electrophysiological research suggests that neurons in mammalian auditory cortex are characterized by broad spatial tuning and a preference for the contralateral hemifield, that is, a nonuniform sampling of sound azimuth. Additionally, spatial selectivity decreases with increasing sound intensity. To accommodate these findings, it has been proposed that sound location is encoded by the integrated activity of neuronal populations with opposite hemifield tuning ("opponent channel model"). In this study, we investigated the validity of such a model in human AC with functional magnetic resonance imaging (fMRI) and a phase-encoding paradigm employing binaural stimuli recorded individually for each participant. In all subjects, we observed preferential fMRI responses to contralateral azimuth positions. Additionally, in most AC locations, spatial tuning was broad and not level invariant. We derived an opponent channel model of the fMRI responses by subtracting the activity of contralaterally tuned regions in bilateral planum temporale. This resulted in accurate decoding of sound azimuth location, which was unaffected by changes in sound level. Our data thus support opponent channel coding as a neural mechanism for representing acoustic azimuth in human AC. © The Author 2015. Published by Oxford University Press.
Detection System of Sound Noise Level (SNL) Based on Condenser Microphone Sensor
NASA Astrophysics Data System (ADS)
Rajagukguk, Juniastel; Eka Sari, Nurdieni
2018-03-01
The research aims to know the noise level by using the Arduino Uno as data processing input from sensors and called as Sound Noise Level (SNL). The working principle of the instrument is as noise detector with the show notifications the noise level on the LCD indicator and in the audiovisual form. Noise detection using the sensor is a condenser microphone and LM 567 as IC op-amps, which are assembled so that it can detect the noise, which sounds are captured by the sensor will turn the tide of sinusoida voice became sine wave energy electricity (altering sinusoida electric current) that is able to responded to complaints by the Arduino Uno. The tool is equipped with a detector consists of a set indicator LED and sound well as the notification from the text on LCD 16*2. Work setting indicators on the condition that, if the measured noise > 75 dB then sound will beep, the red LED will light up indicating the status of the danger. If the measured value on the LCD is higher than 56 dB, sound indicator will be beep and yellow LED will be on indicating noisy. If the noise measured value <55 dB, sound indicator will be quiet indicating peaceful from noisy. From the result of the research can be explained that the SNL is capable to detecting and displaying noise level with a measuring range 50-100 dB and capable to delivering the notification noise in audiovisual.
NASA Astrophysics Data System (ADS)
Wang, Y. S.; Shen, G. Q.; Xing, Y. F.
2014-03-01
Based on the artificial neural network (ANN) technique, an objective sound quality evaluation (SQE) model for synthesis annoyance of vehicle interior noises is presented in this paper. According to the standard named GB/T18697, firstly, the interior noises under different working conditions of a sample vehicle are measured and saved in a noise database. Some mathematical models for loudness, sharpness and roughness of the measured vehicle noises are established and performed by Matlab programming. Sound qualities of the vehicle interior noises are also estimated by jury tests following the anchored semantic differential (ASD) procedure. Using the objective and subjective evaluation results, furthermore, an ANN-based model for synthetical annoyance evaluation of vehicle noises, so-called ANN-SAE, is developed. Finally, the ANN-SAE model is proved by some verification tests with the leave-one-out algorithm. The results suggest that the proposed ANN-SAE model is accurate and effective and can be directly used to estimate sound quality of the vehicle interior noises, which is very helpful for vehicle acoustical designs and improvements. The ANN-SAE approach may be extended to deal with other sound-related fields for product quality evaluations in SQE engineering.
Drilling and operational sounds from an oil production island in the ice-covered Beaufort sea.
Blackwell, Susanna B; Greene, Charles R; Richardson, W John
2004-11-01
Recordings of sounds underwater and in air, and of iceborne vibrations, were obtained at Northstar Island, an artificial gravel island in the Beaufort Sea near Prudhoe Bay (Alaska). The aim was to document the levels, characteristics, and range dependence of sounds and vibrations produced by drilling and oil production during the winter, when the island was surrounded by shore-fast ice. Drilling produced the highest underwater broadband (10-10,000 Hz) levels (maximum= 124 dB re: 1 microPa at 1 km), and mainly affected 700-1400 Hz frequencies. In contrast, drilling did not increase broadband levels in air or ice relative to levels during other island activities. Production did not increase broadband levels for any of the sensors. In all media, broadband levels decreased by approximately 20 dB/tenfold change in distance. Background levels underwater were reached by 9.4 km during drilling and 3-4 km without. In the air and ice, background levels were reached 5-10 km and 2-10 km from Northstar, respectively, depending on the wind but irrespective of drilling. A comparison of the recorded sounds with harbor and ringed seal audiograms showed that Northstar sounds were probably audible to seals, at least intermittently, out to approximately 1.5 km in water and approximately 5 km in air.
A method for evaluating the relation between sound source segregation and masking
Lutfi, Robert A.; Liu, Ching-Ju
2011-01-01
Sound source segregation refers to the ability to hear as separate entities two or more sound sources comprising a mixture. Masking refers to the ability of one sound to make another sound difficult to hear. Often in studies, masking is assumed to result from a failure of segregation, but this assumption may not always be correct. Here a method is offered to identify the relation between masking and sound source segregation in studies and an example is given of its application. PMID:21302979
Airborne sound transmission loss characteristics of woodframe construction
Fred F. Rudder
1985-01-01
This report summarizes the available data on the airborne sound transmission loss properties of wood-frame construction and evaluates the methods for predicting the airborne sound transmission loss. The first part of the report comprises a summary of sound transmission loss data for wood-frame interior walls and floor-ceiling construction. Data bases describing the...
Evaluating Warning Sound Urgency with Reaction Times
ERIC Educational Resources Information Center
Suied, Clara; Susini, Patrick; McAdams, Stephen
2008-01-01
It is well-established that subjective judgments of perceived urgency of alarm sounds can be affected by acoustic parameters. In this study, the authors investigated an objective measurement, the reaction time (RT), to test the effectiveness of temporal parameters of sounds in the context of warning sounds. Three experiments were performed using a…
Letter-Sound Reading: Teaching Preschool Children Print-to-Sound Processing
ERIC Educational Resources Information Center
Wolf, Gail Marie
2016-01-01
This intervention study investigated the growth of letter sound reading and growth of consonant-vowel-consonant (CVC) word decoding abilities for a representative sample of 41 US children in preschool settings. Specifically, the study evaluated the effectiveness of a 3-step letter-sound teaching intervention in teaching preschool children to…
Similar Sound Separation and Cumulative Introduction in Learning Letter-Sound Correspondences
ERIC Educational Resources Information Center
Carnine, Douglas W.
1976-01-01
Since similarity inhibits learning, children will have greater difficulty learning responses that are more similar to each other; the instructional procedure of separating similar sounds was evaluated in two experiments. (DMT)
Not all carp are created equal: Impacts of broadband sound on common carp swimming behavior
Murchy, Kelsie; Vetter, Brooke J.; Brey, Marybeth; Amberg, Jon J.; Gaikowski, Mark; Mensinger, Allen F.
2016-01-01
Bighead carp (Hypophthalmichthys nobilis), silver carp (H. molitrix) (hereafter: bigheaded carps), and common carp (Cyprinus carpio) are invasive fish causing negative impacts throughout their North American range. To control their movements, non-physical barriers are being developed. Broadband sound (0.06 to 10 kHz) has shown potential as an acoustic deterrent for bigheaded carps, but the response of common carp to broadband sound has not been evaluated. Since common carp are ostariophysians, possessing Weberian ossicles similar to bigheaded carps, it is possible that sound can be used as an acoustical deterrent for all three species. Behavioral responses to a broadband sound were evaluated for common carp in an outdoor concrete pond. Common carp responded a median of 3.0 (1st Q: 1.0, 3rd Q: 6.0) consecutive times to the broadband sound which was lower than silver carp and bighead carp to the same stimulus. The current study shows that common carp demonstrate an inconsistent negative phonotaxis response to a broadband sound, and seem to habituate to the sound quickly.
AVE/VAS 4: 25-mb sounding data
NASA Technical Reports Server (NTRS)
Sienkiewicz, M. E.
1983-01-01
The rawinsonde sounding program is described and tabulated data at 25 mb intervals for the 24 stations and 14 special stations participating in the experiment is presented. Sounding were taken at 3 hr intervals. An additional sounding was taken at the normal synoptic observation time. Some soundings were computed from raw ordinate data, while others were interpolated from significant level data.
Interpolated Sounding and Gridded Sounding Value-Added Products
DOE Office of Scientific and Technical Information (OSTI.GOV)
Toto, T.; Jensen, M.
Standard Atmospheric Radiation Measurement (ARM) Climate Research Facility sounding files provide atmospheric state data in one dimension of increasing time and height per sonde launch. Many applications require a quick estimate of the atmospheric state at higher time resolution. The INTERPOLATEDSONDE (i.e., Interpolated Sounding) Value-Added Product (VAP) transforms sounding data into continuous daily files on a fixed time-height grid, at 1-minute time resolution, on 332 levels, from the surface up to a limit of approximately 40 km. The grid extends that high so the full height of soundings can be captured; however, most soundings terminate at an altitude between 25more » and 30 km, above which no data is provided. Between soundings, the VAP linearly interpolates atmospheric state variables in time for each height level. In addition, INTERPOLATEDSONDE provides relative humidity scaled to microwave radiometer (MWR) observations.The INTERPOLATEDSONDE VAP, a continuous time-height grid of relative humidity-corrected sounding data, is intended to provide input to higher-order products, such as the Merged Soundings (MERGESONDE; Troyan 2012) VAP, which extends INTERPOLATEDSONDE by incorporating model data. The INTERPOLATEDSONDE VAP also is used to correct gaseous attenuation of radar reflectivity in products such as the KAZRCOR VAP.« less
Claes, Raf; Muyshondt, Pieter G G; Dirckx, Joris J J; Aerts, Peter
2018-02-01
High sound pressure levels (>120dB) cause damage or death of the hair cells of the inner ear, hence causing hearing loss. Vocalization differences are present between hens and roosters. Crowing in roosters is reported to produce sound pressure levels of 100dB measured at a distance of 1m. In this study we measured the sound pressure levels that exist at the entrance of the outer ear canal. We hypothesize that roosters may benefit from a passive protective mechanism while hens do not require such a mechanism. Audio recordings at the level of the entrance of the outer ear canal of crowing roosters, made in this study, indeed show that a protective mechanism is needed as sound pressure levels can reach amplitudes of 142.3dB. Audio recordings made at varying distances from the crowing rooster show that at a distance of 0.5m sound pressure levels already drop to 102dB. Micro-CT scans of a rooster and chicken head show that in roosters the auditory canal closes when the beak is opened. In hens the diameter of the auditory canal only narrows but does not close completely. A morphological difference between the sexes in shape of a bursa-like slit which occurs in the outer ear canal causes the outer ear canal to close in roosters but not in hens. Copyright © 2017 Elsevier GmbH. All rights reserved.
Effects of fixed labial orthodontic appliances on speech sound production.
Paley, Jonathan S; Cisneros, George J; Nicolay, Olivier F; LeBlanc, Etoile M
2016-05-01
To explore the impact of fixed labial orthodontic appliances on speech sound production. Speech evaluations were performed on 23 patients with fixed labial appliances. Evaluations were performed immediately prior to appliance insertion, immediately following insertion, and 1 and 2 months post insertion. Baseline dental/skeletal variables were correlated with the ability to accommodate the presence of the appliances. Appliance effects were variable: 44% of the subjects were unaffected, 39% were temporarily affected but adapted within 2 months, and 17% of patients showed persistent sound errors at 2 months. Resolution of acquired sound errors was noted by 8 months post-appliance removal. Maladaptation to appliances was correlated to severity of malocclusion as determined by the Grainger's Treatment Priority Index. Sibilant sounds, most notably /s/, were affected most often. (1) Insertion of fixed labial appliances has an effect on speech sound production. (2) Sibilant and stopped sounds are affected, with /s/ being affected most often. (3) Accommodation to fixed appliances depends on the severity of malocclusion.
49 CFR 227.103 - Noise monitoring program.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., significant variations in sound level, or a significant component of impulse noise make area monitoring... results. (c) Noise measurements. (1) All continuous, intermittent, and impulse sound levels from 80...
49 CFR 227.103 - Noise monitoring program.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., significant variations in sound level, or a significant component of impulse noise make area monitoring... results. (c) Noise measurements. (1) All continuous, intermittent, and impulse sound levels from 80...
49 CFR 227.103 - Noise monitoring program.
Code of Federal Regulations, 2013 CFR
2013-10-01
..., significant variations in sound level, or a significant component of impulse noise make area monitoring... results. (c) Noise measurements. (1) All continuous, intermittent, and impulse sound levels from 80...
Santos, Juliana Feitosa dos; Souza, Ana Paula Ramos de; Seligman, Lilian
2013-01-01
To analyze the possible relationships between high sound pressure levels in the classroom and performance in the use of lexical and phonological routes in reading and writing. This consisted on a quantitative and exploratory study. The following measures were carried out: acoustic measurement, using the dosimeter, visual inspection of the external auditory canal, tonal audiometry thresholds, speech recognition tests and acoustic immittance; instrument for evaluation of reading and writing of isolated words. The non-parametric χ² test and Fisher's exact test were used for data analysis. The results of acoustic measurements in 4 schools in Santa Maria divided the sample of 87 children of third and fourth years of primary school, aged 8 to 10 years, in 2 groups. The 1st group was exposed to sound levels higher than 80 dB(A) (Study group) and the 2nd group at levels lower than 80 dB(A) (Control group). Higher prevalence of correct answers in reading and writing of nonwords, reading irregular words and frequency effect were observed. Predominance of correct answers in the writing of irregular words was observed in the Control group. For the Study group, a higher number of type errors neologism in reading and writing were observed, especially regarding the writing of nonwords and the extension effect; fewer errors of lexicalization type and verbal paragraphy in writing were observed. In assessing the reading and writing skills, children in the Study group exposed to high noise levels had poorer performance in the use of lexical and phonological routes, both in reading and in writing.
Enhancement of lung sounds based on empirical mode decomposition and Fourier transform algorithm.
Mondal, Ashok; Banerjee, Poulami; Somkuwar, Ajay
2017-02-01
There is always heart sound (HS) signal interfering during the recording of lung sound (LS) signals. This obscures the features of LS signals and creates confusion on pathological states, if any, of the lungs. In this work, a new method is proposed for reduction of heart sound interference which is based on empirical mode decomposition (EMD) technique and prediction algorithm. In this approach, first the mixed signal is split into several components in terms of intrinsic mode functions (IMFs). Thereafter, HS-included segments are localized and removed from them. The missing values of the gap thus produced, is predicted by a new Fast Fourier Transform (FFT) based prediction algorithm and the time domain LS signal is reconstructed by taking an inverse FFT of the estimated missing values. The experiments have been conducted on simulated and recorded HS corrupted LS signals at three different flow rates and various SNR levels. The performance of the proposed method is evaluated by qualitative and quantitative analysis of the results. It is found that the proposed method is superior to the baseline method in terms of quantitative and qualitative measurement. The developed method gives better results compared to baseline method for different SNR levels. Our method gives cross correlation index (CCI) of 0.9488, signal to deviation ratio (SDR) of 9.8262, and normalized maximum amplitude error (NMAE) of 26.94 for 0 dB SNR value. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Cell type-specific suppression of mechanosensitive genes by audible sound stimulation.
Kumeta, Masahiro; Takahashi, Daiji; Takeyasu, Kunio; Yoshimura, Shige H
2018-01-01
Audible sound is a ubiquitous environmental factor in nature that transmits oscillatory compressional pressure through the substances. To investigate the property of the sound as a mechanical stimulus for cells, an experimental system was set up using 94.0 dB sound which transmits approximately 10 mPa pressure to the cultured cells. Based on research on mechanotransduction and ultrasound effects on cells, gene responses to the audible sound stimulation were analyzed by varying several sound parameters: frequency, wave form, composition, and exposure time. Real-time quantitative PCR analyses revealed a distinct suppressive effect for several mechanosensitive and ultrasound-sensitive genes that were triggered by sounds. The effect was clearly observed in a wave form- and pressure level-specific manner, rather than the frequency, and persisted for several hours. At least two mechanisms are likely to be involved in this sound response: transcriptional control and RNA degradation. ST2 stromal cells and C2C12 myoblasts exhibited a robust response, whereas NIH3T3 cells were partially and NB2a neuroblastoma cells were completely insensitive, suggesting a cell type-specific response to sound. These findings reveal a cell-level systematic response to audible sound and uncover novel relationships between life and sound.
Cell type-specific suppression of mechanosensitive genes by audible sound stimulation
Takahashi, Daiji; Takeyasu, Kunio; Yoshimura, Shige H.
2018-01-01
Audible sound is a ubiquitous environmental factor in nature that transmits oscillatory compressional pressure through the substances. To investigate the property of the sound as a mechanical stimulus for cells, an experimental system was set up using 94.0 dB sound which transmits approximately 10 mPa pressure to the cultured cells. Based on research on mechanotransduction and ultrasound effects on cells, gene responses to the audible sound stimulation were analyzed by varying several sound parameters: frequency, wave form, composition, and exposure time. Real-time quantitative PCR analyses revealed a distinct suppressive effect for several mechanosensitive and ultrasound-sensitive genes that were triggered by sounds. The effect was clearly observed in a wave form- and pressure level-specific manner, rather than the frequency, and persisted for several hours. At least two mechanisms are likely to be involved in this sound response: transcriptional control and RNA degradation. ST2 stromal cells and C2C12 myoblasts exhibited a robust response, whereas NIH3T3 cells were partially and NB2a neuroblastoma cells were completely insensitive, suggesting a cell type-specific response to sound. These findings reveal a cell-level systematic response to audible sound and uncover novel relationships between life and sound. PMID:29385174
Meteorological effects on long-range outdoor sound propagation
NASA Technical Reports Server (NTRS)
Klug, Helmut
1990-01-01
Measurements of sound propagation over distances up to 1000 m were carried out with an impulse sound source offering reproducible, short time signals. Temperature and wind speed at several heights were monitored simultaneously; the meteorological data are used to determine the sound speed gradients according to the Monin-Obukhov similarity theory. The sound speed profile is compared to a corresponding prediction, gained through the measured travel time difference between direct and ground reflected pulse (which depends on the sound speed gradient). Positive sound speed gradients cause bending of the sound rays towards the ground yielding enhanced sound pressure levels. The measured meteorological effects on sound propagation are discussed and illustrated by ray tracing methods.
Applications of direct-to-consumer hearing devices for adults with hearing loss: a review
Manchaiah, Vinaya; Taylor, Brian; Dockens, Ashley L; Tran, Nicole R; Lane, Kayla; Castle, Mariana; Grover, Vibhu
2017-01-01
Background This systematic literature review is aimed at investigating applications of direct-to-consumer hearing devices for adults with hearing loss. This review discusses three categories of direct-to-consumer hearing devices: 1) personal sound amplification products (PSAPs), 2) direct-mail hearing aids, and 3) over-the-counter (OTC) hearing aids. Method A literature review was conducted using EBSCOhost and included the databases CINAHL, MEDLINE, and PsycINFO. After applying prior agreed inclusion and exclusion criteria, 13 reports were included in the review. Results Included studies fell into three domains: 1) electroacoustic characteristics, 2) consumer surveys, and 3) outcome evaluations. Electroacoustic characteristics of these devices vary significantly with some meeting the stringent acoustic criteria used for hearing aids, while others producing dangerous output levels (ie, over 120-dB sound pressure level). Low-end (or low-cost) devices were typically poor in acoustic quality and did not meet gain levels necessary for most adult and elderly hearing loss patterns (eg, presbycusis), especially in high frequencies. Despite direct-mail hearing aids and PSAPs being associated with lower satisfaction when compared to hearing aids purchased through hearing health care professionals, consumer surveys suggest that 5%–19% of people with hearing loss purchase hearing aids through direct-mail or online. Studies on outcome evaluation suggest positive outcomes of OTC devices in the elderly population. Of note, OTC outcomes appear better when a hearing health care professional supports these users. Conclusion While some direct-to-consumer hearing devices have the capability to produce adverse effects due to production of dangerously high sound levels and internal noise, the existing literature suggests that there are potential benefits of these devices. Research of direct-to-consumer hearing devices is limited, and current published studies are of weak quality. Much effort is needed to understand the benefits and limitations of such devices on people with hearing loss. PMID:28553093
Applications of direct-to-consumer hearing devices for adults with hearing loss: a review.
Manchaiah, Vinaya; Taylor, Brian; Dockens, Ashley L; Tran, Nicole R; Lane, Kayla; Castle, Mariana; Grover, Vibhu
2017-01-01
This systematic literature review is aimed at investigating applications of direct-to-consumer hearing devices for adults with hearing loss. This review discusses three categories of direct-to-consumer hearing devices: 1) personal sound amplification products (PSAPs), 2) direct-mail hearing aids, and 3) over-the-counter (OTC) hearing aids. A literature review was conducted using EBSCOhost and included the databases CINAHL, MEDLINE, and PsycINFO. After applying prior agreed inclusion and exclusion criteria, 13 reports were included in the review. Included studies fell into three domains: 1) electroacoustic characteristics, 2) consumer surveys, and 3) outcome evaluations. Electroacoustic characteristics of these devices vary significantly with some meeting the stringent acoustic criteria used for hearing aids, while others producing dangerous output levels (ie, over 120-dB sound pressure level). Low-end (or low-cost) devices were typically poor in acoustic quality and did not meet gain levels necessary for most adult and elderly hearing loss patterns (eg, presbycusis), especially in high frequencies. Despite direct-mail hearing aids and PSAPs being associated with lower satisfaction when compared to hearing aids purchased through hearing health care professionals, consumer surveys suggest that 5%-19% of people with hearing loss purchase hearing aids through direct-mail or online. Studies on outcome evaluation suggest positive outcomes of OTC devices in the elderly population. Of note, OTC outcomes appear better when a hearing health care professional supports these users. While some direct-to-consumer hearing devices have the capability to produce adverse effects due to production of dangerously high sound levels and internal noise, the existing literature suggests that there are potential benefits of these devices. Research of direct-to-consumer hearing devices is limited, and current published studies are of weak quality. Much effort is needed to understand the benefits and limitations of such devices on people with hearing loss.
Sound Wave Energy Resulting from the Impact of Water Drops on the Soil Surface
Ryżak, Magdalena; Bieganowski, Andrzej; Korbiel, Tomasz
2016-01-01
The splashing of water drops on a soil surface is the first step of water erosion. There have been many investigations into splashing–most are based on recording and analysing images taken with high-speed cameras, or measuring the mass of the soil moved by splashing. Here, we present a new aspect of the splash phenomenon’s characterization the measurement of the sound pressure level and the sound energy of the wave that propagates in the air. The measurements were carried out for 10 consecutive water drop impacts on the soil surface. Three soils were tested (Endogleyic Umbrisol, Fluvic Endogleyic Cambisol and Haplic Chernozem) with four initial moisture levels (pressure heads: 0.1 kPa, 1 kPa, 3.16 kPa and 16 kPa). We found that the values of the sound pressure and sound wave energy were dependent on the particle size distribution of the soil, less dependent on the initial pressure head, and practically the same for subsequent water drops (from the first to the tenth drop). The highest sound pressure level (and the greatest variability) was for Endogleyic Umbrisol, which had the highest sand fraction content. The sound pressure for this soil increased from 29 dB to 42 dB with the next incidence of drops falling on the sample The smallest (and the lowest variability) was for Fluvic Endogleyic Cambisol which had the highest clay fraction. For all experiments the sound pressure level ranged from ~27 to ~42 dB and the energy emitted in the form of sound waves was within the range of 0.14 μJ to 5.26 μJ. This was from 0.03 to 1.07% of the energy of the incident drops. PMID:27388276
Sound Wave Energy Resulting from the Impact of Water Drops on the Soil Surface.
Ryżak, Magdalena; Bieganowski, Andrzej; Korbiel, Tomasz
2016-01-01
The splashing of water drops on a soil surface is the first step of water erosion. There have been many investigations into splashing-most are based on recording and analysing images taken with high-speed cameras, or measuring the mass of the soil moved by splashing. Here, we present a new aspect of the splash phenomenon's characterization the measurement of the sound pressure level and the sound energy of the wave that propagates in the air. The measurements were carried out for 10 consecutive water drop impacts on the soil surface. Three soils were tested (Endogleyic Umbrisol, Fluvic Endogleyic Cambisol and Haplic Chernozem) with four initial moisture levels (pressure heads: 0.1 kPa, 1 kPa, 3.16 kPa and 16 kPa). We found that the values of the sound pressure and sound wave energy were dependent on the particle size distribution of the soil, less dependent on the initial pressure head, and practically the same for subsequent water drops (from the first to the tenth drop). The highest sound pressure level (and the greatest variability) was for Endogleyic Umbrisol, which had the highest sand fraction content. The sound pressure for this soil increased from 29 dB to 42 dB with the next incidence of drops falling on the sample The smallest (and the lowest variability) was for Fluvic Endogleyic Cambisol which had the highest clay fraction. For all experiments the sound pressure level ranged from ~27 to ~42 dB and the energy emitted in the form of sound waves was within the range of 0.14 μJ to 5.26 μJ. This was from 0.03 to 1.07% of the energy of the incident drops.
The isolation of low frequency impact sounds in hotel construction
NASA Astrophysics Data System (ADS)
LoVerde, John J.; Dong, David W.
2002-11-01
One of the design challenges in the acoustical design of hotels is reducing low frequency sounds from footfalls occurring on both carpeted and hard-surfaced floors. Research on low frequency impact noise [W. Blazier and R. DuPree, J. Acoust. Soc. Am. 96, 1521-1532 (1994)] resulted in a conclusion that in wood construction low frequency impact sounds were clearly audible and that feasible control methods were not available. The results of numerous FIIC (Field Impact Insulation Class) measurements performed in accordance with ASTM E1007 indicate the lack of correlation between FIIC ratings and the reaction of occupants in the room below. The measurements presented include FIIC ratings and sound pressure level measurements below the ASTM E1007 low frequency limit of 100 Hertz, and reveal that excessive sound levels in the frequency range of 63 to 100 Hertz correlate with occupant complaints. Based upon this history, a tentative criterion for maximum impact sound level in the low frequency range is presented. The results presented of modifying existing constructions to reduce the transmission of impact sounds at low frequencies indicate that there may be practical solutions to this longstanding problem.
[Expression of NR2A in rat auditory cortex after sound insulation and auditory plasticity].
Xia, Yin; Long, Haishan; Han, Demin; Gong, Shusheng; Lei, Li; Shi, Jinfeng; Fan, Erzhong; Li, Ying; Zhao, Qing
2009-06-01
To study the changes of N-methyl-D-aspartate (NMDA) receptor subunit 2A (NR2A) expression at local synapses in auditory cortices after early postnatal sound insulation and tone exposure. We prepared highly purified synaptosomes from primary auditory cortex by Optiprep flotation gradient centrifugations, and compared the differences of NR2A expression in sound insulation PND14, PND28, PND42 and Tone exposure after sound insulation for 7 days by Western blotting. The results showed that the NR2A protein expression of PND14 and PND28 decreased significantly (P<0.05). Tone exposure after sound insulation for 7 days, mSIe NR2A protein level increased significantly (P<0.05). It showed bidirectional regulation of NR2A protein. No significant effects of sound insulation and lone exposure were found on the relative expression level of NR2A of PND42 (P>0.05). The results indicate that sound insulation and experience can modify the protein expression level of NR2A during the critical period of rat postnatal development. These findings provide important data for the study on the mechanisms of the developmental plasticity of sensory functions.
Measurement and characterisation of radiated underwater sound from a 3.6 MW monopile wind turbine.
Pangerc, Tanja; Theobald, Peter D; Wang, Lian S; Robinson, Stephen P; Lepper, Paul A
2016-10-01
This paper describes underwater sound pressure measurements obtained in close proximity (∼50 m) to two individual wind turbines, over a 21-day period, capturing the full range of turbine operating conditions. The sound radiated into the water was characterised by a number of tonal components, which are thought to primarily originate from the gearbox for the bandwidth measured. The main signal associated with the turbine operation had a mean-square sound pressure spectral density level which peaked at 126 dB re 1 μPa 2 Hz -1 at 162 Hz. Other tonal components were also present, notably at frequencies between about 20 and 330 Hz, albeit at lower amplitudes. The measured sound characteristics, both in terms of frequency and amplitude, were shown to vary with wind speed. The sound pressure level increased with wind speed up to an average value of 128 dB re 1 μPa at a wind speed of about 10 ms -1 , and then showed a general decrease. Overall, differences in the mean-square sound pressure spectral density level of over 20 dB were observed across the operational envelope of the turbine.
Lenzuni, Paolo
2015-07-01
The purpose of this article is to develop a method for the statistical inference of the maximum peak sound pressure level and of the associated uncertainty. Both quantities are requested by the EU directive 2003/10/EC for a complete and solid assessment of the noise exposure at the workplace. Based on the characteristics of the sound pressure waveform, it is hypothesized that the distribution of the measured peak sound pressure levels follows the extreme value distribution. The maximum peak level is estimated as the largest member of a finite population following this probability distribution. The associated uncertainty is also discussed, taking into account not only the contribution due to the incomplete sampling but also the contribution due to the finite precision of the instrumentation. The largest of the set of measured peak levels underestimates the maximum peak sound pressure level. The underestimate can be as large as 4 dB if the number of measurements is limited to 3-4, which is common practice in occupational noise assessment. The extended uncertainty is also quite large (~2.5 dB), with a weak dependence on the sampling details. Following the procedure outlined in this article, a reliable comparison between the peak sound pressure levels measured in a workplace and the EU directive action limits is possible. Non-compliance can occur even when the largest of the set of measured peak levels is several dB below such limits. © The Author 2015. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
Sound preference test in animal models of addicts and phobias.
Soga, Ryo; Shiramatsu, Tomoyo I; Kanzaki, Ryohei; Takahashi, Hirokazu
2016-08-01
Biased or too strong preference for a particular object is often problematic, resulting in addiction and phobia. In animal models, alternative forced-choice tasks have been routinely used, but such preference test is far from daily situations that addicts or phobic are facing. In the present study, we developed a behavioral assay to evaluate the preference of sounds in rodents. In the assay, several sounds were presented according to the position of free-moving rats, and quantified the sound preference based on the behavior. A particular tone was paired with microstimulation to the ventral tegmental area (VTA), which plays central roles in reward processing, to increase sound preference. The behaviors of rats were logged during the classical conditioning for six days. Consequently, some behavioral indices suggest that rats search for the conditioned sound. Thus, our data demonstrated that quantitative evaluation of preference in the behavioral assay is feasible.
Mapping the sound field of an erupting submarine volcano using an acoustic glider.
Matsumoto, Haru; Haxel, Joseph H; Dziak, Robert P; Bohnenstiehl, Delwayne R; Embley, Robert W
2011-03-01
An underwater glider with an acoustic data logger flew toward a recently discovered erupting submarine volcano in the northern Lau basin. With the volcano providing a wide-band sound source, recordings from the two-day survey produced a two-dimensional sound level map spanning 1 km (depth) × 40 km(distance). The observed sound field shows depth- and range-dependence, with the first-order spatial pattern being consistent with the predictions of a range-dependent propagation model. The results allow constraining the acoustic source level of the volcanic activity and suggest that the glider provides an effective platform for monitoring natural and anthropogenic ocean sounds. © 2011 Acoustical Society of America
Designing Trend-Monitoring Sounds for Helicopters: Methodological Issues and an Application
ERIC Educational Resources Information Center
Edworthy, Judy; Hellier, Elizabeth; Aldrich, Kirsteen; Loxley, Sarah
2004-01-01
This article explores methodological issues in sonification and sound design arising from the design of helicopter monitoring sounds. Six monitoring sounds (each with 5 levels) were tested for similarity and meaning with 3 different techniques: hierarchical cluster analysis, linkage analysis, and multidimensional scaling. In Experiment 1,…
Kastelein, Ronald A; Wensveen, Paul J; Terhune, John M; de Jong, Christ A F
2011-01-01
Equal-loudness functions describe relationships between the frequencies of sounds and their perceived loudness. This pilot study investigated the possibility of deriving equal-loudness contours based on the assumption that sounds of equal perceived loudness elicit equal reaction times (RTs). During a psychoacoustic underwater hearing study, the responses of two young female harbor seals to tonal signals between 0.125 and 100 kHz were filmed. Frame-by-frame analysis was used to quantify RT (the time between the onset of the sound stimulus and the onset of movement of the seal away from the listening station). Near-threshold equal-latency contours, as surrogates for equal-loudness contours, were estimated from RT-level functions fitted to mean RT data. The closer the received sound pressure level was to the 50% detection hearing threshold, the more slowly the animals reacted to the signal (RT range: 188-982 ms). Equal-latency contours were calculated relative to the RTs shown by each seal at sound levels of 0, 10, and 20 dB above the detection threshold at 1 kHz. Fifty percent detection thresholds are obtained with well-trained subjects actively listening for faint familiar sounds. When calculating audibility ranges of sounds for harbor seals in nature, it may be appropriate to consider levels 20 dB above this threshold.
Kok, Annebelle C M; Engelberts, J Pamela; Kastelein, Ronald A; Helder-Hoek, Lean; Van de Voorde, Shirley; Visser, Fleur; Slabbekoorn, Hans
2018-02-01
The continuing rise in underwater sound levels in the oceans leads to disturbance of marine life. It is thought that one of the main impacts of sound exposure is the alteration of foraging behaviour of marine species, for example by deterring animals from a prey location, or by distracting them while they are trying to catch prey. So far, only limited knowledge is available on both mechanisms in the same species. The harbour porpoise (Phocoena phocoena) is a relatively small marine mammal that could quickly suffer fitness consequences from a reduction of foraging success. To investigate effects of anthropogenic sound on their foraging efficiency, we tested whether experimentally elevated sound levels would deter two captive harbour porpoises from a noisy pool into a quiet pool (Experiment 1) and reduce their prey-search performance, measured as prey-search time in the noisy pool (Experiment 2). Furthermore, we tested the influence of the temporal structure and amplitude of the sound on the avoidance response of both animals. Both individuals avoided the pool with elevated sound levels, but they did not show a change in search time for prey when trying to find a fish hidden in one of three cages. The combination of temporal structure and SPL caused variable patterns. When the sound was intermittent, increased SPL caused increased avoidance times. When the sound was continuous, avoidance was equal for all SPLs above a threshold of 100 dB re 1 μPa. Hence, we found no evidence for an effect of sound exposure on search efficiency, but sounds of different temporal patterns did cause spatial avoidance with distinct dose-response patterns. Copyright © 2017 Elsevier Ltd. All rights reserved.
Sound Exposure of Healthcare Professionals Working with a University Marching Band.
Russell, Jeffrey A; Yamaguchi, Moegi
2018-01-01
Music-induced hearing disorders are known to result from exposure to excessive levels of music of different genres. Marching band music, with its heavy emphasis on brass and percussion, is one type that is a likely contributor to music-induced hearing disorders, although specific data on sound pressure levels of marching bands have not been widely studied. Furthermore, if marching band music does lead to music-induced hearing disorders, the musicians may not be the only individuals at risk. Support personnel such as directors, equipment managers, and performing arts healthcare providers may also be exposed to potentially damaging sound pressures. Thus, we sought to explore to what degree healthcare providers receive sound dosages above recommended limits during their work with a marching band. The purpose of this study was to determine the sound exposure of healthcare professionals (specifically, athletic trainers [ATs]) who provide on-site care to a large, well-known university marching band. We hypothesized that sound pressure levels to which these individuals were exposed would exceed the National Institute for Occupational Safety and Health (NIOSH) daily percentage allowance. Descriptive observational study. Eight ATs working with a well-known American university marching band volunteered to wear noise dosimeters. During the marching band season, ATs wore an Etymotic ER-200D dosimeter whenever working with the band at outdoor rehearsals, indoor field house rehearsals, and outdoor performances. The dosimeters recorded dose percent exposure, equivalent continuous sound levels in A-weighted decibels, and duration of exposure. For comparison, a dosimeter also was worn by an AT working in the university's performing arts medicine clinic. Participants did not alter their typical duties during any data collection sessions. Sound data were collected with the dosimeters set at the NIOSH standards of 85 dBA threshold and 3 dBA exchange rate; the NIOSH 100% daily dose is an exposure to 85 dBA over 8 h. Dose data for each session were converted to a standardized dose intensity by dividing the dose percentage by the duration of the exposure and setting the NIOSH standard as a factor of 1.0. This allowed convenient relative comparisons of dose percentages of vastly different exposure durations. Analysis of variance examined relationships of noise exposures among the venues; post hoc testing was used to assess pairwise differences. As hypothesized, ATs were exposed to high sound pressure levels and dose percentages greatly exceeding those recommended by NIOSH. Higher sound levels were recorded in performance venues compared with rehearsal venues. In addition to the band music, crowd noise and public address systems contribute to high sound levels at performances. Our results suggest that healthcare providers working with marching bands are exposed to dangerous levels of sound during performances. This is especially true at venues such as football stadiums, where crowd noise and public address systems add to sound pressure. A hearing conservation program, including protection, should be required for all healthcare staff who work with marching bands. Moreover, our results should inform hearing conservation practices for marching musicians, directors, and support personnel. American Academy of Audiology
Caporali, Priscila Faissola; Caporali, Sueli Aparecida; Bucuvic, Érika Cristina; Vieira, Sheila de Souza; Santos, Zeila Maria; Chiari, Brasília Maria
2016-01-01
Translation and cross-cultural adaptation of the instrument Hearing Implant Sound Quality Index (HISQUI19), and characterization of the target population and auditory performance in Cochlear Implant (CI) users through the application of a synthesis version of this tool. Evaluations of conceptual, item, semantic and operational equivalences were performed. The synthesis version was applied as a pre-test to 33 individuals, whose final results characterized the final sample and performance of the questionnaire. The results were analyzed statistically. The final translation (FT) was back-translated and compared with the original version, revealing a minimum difference between items. The changes observed between the FT and the synthesis version were characterized by the application of simplified vocabulary used on a daily basis. For the pre-test, the average score of the interviewees was 90.2, and a high level of reliability was achieved (0.83). The translation and cross-cultural adaptation of the HISQUI19 questionnaire showed suitability for conceptual, item, semantic and operational equivalences. For the sample characterization, the sound quality was classified as good with better performance for the categories of location and distinction of sound/voices.
NASA Technical Reports Server (NTRS)
Johnson, Marty E.; Fuller, Chris R.; Jones, Michael G. (Technical Monitor)
2000-01-01
In this report both a frequency domain method for creating high level harmonic excitation and a time domain inverse method for creating large pulses in a duct are developed. To create controllable, high level sound an axial array of six JBL-2485 compression drivers was used. The pressure downstream is considered as input voltages to the sources filtered by the natural dynamics of the sources and the duct. It is shown that this dynamic behavior can be compensated for by filtering the inputs such that both time delays and phase changes are taken into account. The methods developed maximize the sound output while (i) keeping within the power constraints of the sources and (ii) maintaining a suitable level of reproduction accuracy. Harmonic excitation pressure levels of over 155dB were created experimentally over a wide frequency range (1000-4000Hz). For pulse excitation there is a tradeoff between accuracy of reproduction and sound level achieved. However, the accurate reproduction of a pulse with a maximum pressure level over 6500Pa was achieved experimentally. It was also shown that the throat connecting the driver to the duct makes it difficult to inject sound just below the cut-on of each acoustic mode (pre cut-on loading effect).
Predicted and Measured Modal Sound Power Levels for a Fan Ingesting Distorted Inflow
NASA Technical Reports Server (NTRS)
Koch, L. Danielle
2010-01-01
Refinements have been made to a method for estimating the modal sound power levels of a ducted fan ingesting distorted inflow. By assuming that each propagating circumferential mode consists only of a single radial mode (the one with the highest cut-off ratio), circumferential mode sound power levels can be computed for a variety of inflow distortion patterns and operating speeds. Predictions from the refined theory have been compared to data from an experiment conducted in the Advanced Noise Control Fan at NASA Glenn Research Center. The inflow to the fan was distorted by inserting cylindrical rods radially into the inlet duct. The rods were placed at an axial location one rotor chord length upstream of the fan and arranged in both regular and irregular circumferential patterns. The fan was operated at 2000, 1800, and 1400 rpm. Acoustic pressure levels were measured in the fan inlet and exhaust ducts using the Rotating Rake fan mode measurement system. Far field sound pressure levels were also measured. It is shown that predicted trends in circumferential mode sound power levels closely match the experimental data for all operating speeds and distortion configurations tested. Insight gained through this work is being used to develop more advanced tools for predicting fan inflow distortion tone noise levels.
Phonological Awareness and Types of Sound Errors in Preschoolers with Speech Sound Disorders
ERIC Educational Resources Information Center
Preston, Jonathan; Edwards, Mary Louise
2010-01-01
Purpose: Some children with speech sound disorders (SSD) have difficulty with literacy-related skills, particularly phonological awareness (PA). This study investigates the PA skills of preschoolers with SSD by using a regression model to evaluate the degree to which PA can be concurrently predicted by types of speech sound errors. Method:…
New non-invasive automatic cough counting program based on 6 types of classified cough sounds.
Murata, Akira; Ohota, Nao; Shibuya, Atsuo; Ono, Hiroshi; Kudoh, Shoji
2006-01-01
Cough consisting of an initial deep inspiration, glottal closure, and an explosive expiration accompanied by a sound is one of the most common symptoms of respiratory disease. Despite its clinical importance, standard methods for objective cough analysis have yet to be established. We investigated the characteristics of cough sounds acoustically, designed a program to discriminate cough sounds from other sounds, and finally developed a new objective method of non-invasive cough counting. In addition, we evaluated the clinical efficacy of that program. We recorded cough sounds using a memory stick IC recorder in free-field from 2 patients and analyzed the intensity of 534 recorded coughs acoustically according to time domain. First we squared the sound waveform of recorded cough sounds, which was then smoothed out over a 20 ms window. The 5 parameters and some definitions to discriminate the cough sounds from other noise were identified and the cough sounds were classified into 6 groups. Next, we applied this method to develop a new automatic cough count program. Finally, to evaluate the accuracy and clinical usefulness of this program, we counted cough sounds collected from another 10 patients using our program and conventional manual counting. And the sensitivity, specificity and discriminative rate of the program were analyzed. This program successfully discriminated recorded cough sounds out of 1902 sound events collected from 10 patients at a rate of 93.1%. The sensitivity was 90.2% and the specificity was 96.5%. Our new cough counting program can be sufficiently useful for clinical studies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
M. P. Jensen; Toto, T.
Standard Atmospheric Radiation Measurement (ARM) Climate Research Facility sounding files provide atmospheric state data in one dimension of increasing time and height per sonde launch. Many applications require a quick estimate of the atmospheric state at higher time resolution. The INTERPOLATEDSONDE (i.e., Interpolated Sounding) Value-Added Product (VAP) transforms sounding data into continuous daily files on a fixed time-height grid, at 1-minute time resolution, on 332 levels, from the surface up to a limit of approximately 40 km. The grid extends that high so the full height of soundings can be captured; however, most soundings terminate at an altitude between 25more » and 30 km, above which no data is provided. Between soundings, the VAP linearly interpolates atmospheric state variables in time for each height level. In addition, INTERPOLATEDSONDE provides relative humidity scaled to microwave radiometer (MWR) observations.« less
Where is the level of neutral buoyancy for deep convection?
NASA Astrophysics Data System (ADS)
Takahashi, Hanii; Luo, Zhengzhao
2012-08-01
This study revisits an old concept in meteorology - level of neutral buoyancy (LNB). The classic definition of LNB is derived from the parcel theory and can be estimated from the ambient sounding (LNB_sounding) without having to observe any actual convective cloud development. In reality, however, convection interacts with the environment in complicated ways; it will eventually manage to find its own effective LNB and manifests it through detraining masses and developing anvils (LNB_observation). This study conducts a near-global survey of LNB_observation for tropical deep convection using CloudSat data and makes comparison with the corresponding LNB_sounding. The principal findings are as follows: First, although LNB_sounding provides a reasonable upper bound for convective development, correlation between LNB_sounding and LNB_observation is low suggesting that ambient sounding contains limited information for accurately predicting the actual LNB. Second, maximum mass outflow is located more than 3 km lower than LNB_sounding. Hence, from convective transport perspective, LNB_sounding is a significant overestimate of the “destination” height level of the detrained mass. Third, LNB_observation is consistently higher over land than over ocean, although LNB_sounding is similar between land and ocean. This difference is likely related to the contrasts in convective strength and environment between land and ocean. Finally, we estimate the bulk entrainment rates associated with the observed deep convection, which can serve as an observational basis for adjusting GCM cumulus parameterization.
The sounds of handheld audio players.
Rudy, Susan F
2007-01-01
Hearing experts and public health organizations have longstanding hearing safety concerns about personal handheld audio devices, which are growing in both number and popularity. This paper reviews the maximum sound levels of handheld compact disc players, MP3 players, and an iPod. It further reviews device factors that influence the sound levels produced by these audio devices and ways to reduce the risk to hearing during their use.
Exploring the effect of sound and music on health in hospital settings: A narrative review.
Iyendo, Timothy Onosahwo
2016-11-01
Sound in hospital space has traditionally been considered in negative terms as both intrusive and unwanted, and based mainly on sound levels. However, sound level is only one aspect of the soundscape. There is strong evidence that exploring the positive aspect of sound in a hospital context can evoke positive feelings in both patients and nurses. Music psychology studies have also shown that music intervention in health care can have a positive effect on patient's emotions and recuperating processes. In this way, hospital spaces have the potential to reduce anxiety and stress, and make patients feel comfortable and secure. This paper describes a review of the literature exploring sound perception and its effect on health care. This review sorted the literature and main issues into themes concerning sound in health care spaces; sound, stress and health; positive soundscape; psychological perspective of music and emotion; music as a complementary medicine for improving health care; contradicting arguments concerning the use of music in health care; and implications for clinical practice. Using Web of Science, PubMed, Scopus, ProQuest Central, MEDLINE, and Google, a literature search on sound levels, sound sources and the impression of a soundscape was conducted. The review focused on the role and use of music on health care in clinical environments. In addition, other pertinent related materials in shaping the understanding of the field were retrieved, scanned and added into this review. The result indicated that not all noises give a negative impression within healthcare soundscapes. Listening to soothing music was shown to reduce stress, blood pressure and post-operative trauma when compared to silence. Much of the sound conveys meaningful information that is positive for both patients and nurses, in terms of soft wind, bird twitter, and ocean sounds. Music perception was demonstrated to bring about positive change in patient-reported outcomes such as eliciting positive emotion, and decreasing the levels of stressful conditions. Whilst sound holds both negative and positive aspects of the hospital ecosystem and may be stressful, it also possesses a soothing quality that induces positive feelings in patients. Conceptualizing the nature of sound in the hospital context as a soundscape, rather than merely noise can permit a subtler and socially useful understanding of the role of sound and music in the hospital setting, thereby creating a means for improving the hospital experience for patients and nurses. Copyright © 2016 Elsevier Ltd. All rights reserved.
Chao, Chun-Tang
2014-01-01
This paper presents the design and evaluation of the hardware circuit for electronic stethoscopes with heart sound cancellation capabilities using field programmable gate arrays (FPGAs). The adaptive line enhancer (ALE) was adopted as the filtering methodology to reduce heart sound attributes from the breath sounds obtained via the electronic stethoscope pickup. FPGAs were utilized to implement the ALE functions in hardware to achieve near real-time breath sound processing. We believe that such an implementation is unprecedented and crucial toward a truly useful, standalone medical device in outpatient clinic settings. The implementation evaluation with one Altera cyclone II–EP2C70F89 shows that the proposed ALE used 45% resources of the chip. Experiments with the proposed prototype were made using DE2-70 emulation board with recorded body signals obtained from online medical archives. Clear suppressions were observed in our experiments from both the frequency domain and time domain perspectives. PMID:24790573
Evaluation of noise impact mitigation protocols to support CSS : final report.
DOT National Transportation Integrated Search
2008-03-01
This research project developed and evaluated practical ways of involving the public in context sensitive sound mitigation strategies. The integrated use of photo montage, PowerPoint presentation, linked traffic sound files, and audience response sys...
Satellite Moisture Retrieval Techniques. Volume 1. Technique Development and Evaluation
1983-01-01
M3H 5T4 ONTARIO, CANADA BIBLIOTECA INSTITUTE ANARTICO CHILENO LUIS THAYER OJEDA 814 SANTIAGO , CHILE METEORO. OFFICE LIBRARY LONDON ROAD...levels (which could in practice be determined from CO2 sounding channels). The water vapor amounts at the different tropospheric levels are the...parameters for the gases H2O, CO2 , O3, N2O, CO, CH4 and O2. Water vapor was the largest contributor to absorption for all SSH/2 channels with smaller
Stapes Displacement and Intracochlear Pressure in Response to Very High Level, Low Frequency Sounds
Greene, Nathaniel T.; Jenkins, Herman A.; Tollin, Daniel J.; Easter, James R.
2018-01-01
The stapes is held in the oval window by the stapedial annular ligament (SAL), which restricts total peak-to-peak displacement of the stapes. Previous studies have suggested that for moderate (< 130 dB SPL) sound levels intracochlear pressure (PIC), measured at the base of the cochlea far from the basilar membrane, increases directly proportionally with stapes displacement (DStap), thus a current model of impulse noise exposure (the Auditory Hazard Assessment Algorithm for Humans, or AHAAH) predicts that peak PIC will vary linearly with DStap up to some saturation point. However, no direct tests of DStap, or of the relationship with PIC during such motion, have been performed during acoustic stimulation of the human ear. In order to examine the relationship between DStap and PIC to very high level sounds, measurements of DStap and PIC were made in cadaveric human temporal bones. Specimens were prepared by mastoidectomy and extended facial recess to expose the ossicular chain. Measurements of PIC were made in scala vestibuli (PSV) and scala tympani (PST), along with the SPL in the external auditory canal (PEAC), concurrently with laser Doppler vibrometry (LDV) measurements of stapes velocity (VStap). Stimuli were moderate (~100 dB SPL) to very high level (up to ~170 dB SPL), low frequency tones (20–2560 Hz). Both DStap and PSV increased proportionally with sound pressure level in the ear canal up to approximately ~150 dB SPL, above which both DStap and PSV showed a distinct deviation from proportionality with PEAC. Both DStap and PSV approached saturation: DStap at a value exceeding 150 μm, which is substantially higher than has been reported for small mammals, while PSV showed substantial frequency dependence in the saturation point. The relationship between PSV and DStap remained constant, and cochlear input impedance did not vary across the levels tested, consistent with prior measurements at lower sound levels. These results suggest that PSV sound pressure holds constant relationship with DStap, described by the cochlear input impedance, at these, but perhaps not higher, stimulation levels. Additionally, these results indicate that the AHAAH model, which was developed using results from small animals, underestimates the sound pressure levels in the cochlea in response to high level sound stimulation, and must be revised. PMID:28189837
An analysis of collegiate band directors' exposure to sound pressure levels
NASA Astrophysics Data System (ADS)
Roebuck, Nikole Moore
Noise-induced hearing loss (NIHL) is a significant but unfortunate common occupational hazard. The purpose of the current study was to measure the magnitude of sound pressure levels generated within a collegiate band room and determine if those sound pressure levels are of a magnitude that exceeds the policy standards and recommendations of the Occupational Safety and Health Administration (OSHA), and the National Institute of Occupational Safety and Health (NIOSH). In addition, reverberation times were measured and analyzed in order to determine the appropriateness of acoustical conditions for the band rehearsal environment. Sound pressure measurements were taken from the rehearsal of seven collegiate marching bands. Single sample t test were conducted to compare the sound pressure levels of all bands to the noise exposure standards of OSHA and NIOSH. Multiple regression analysis were conducted and analyzed in order to determine the effect of the band room's conditions on the sound pressure levels and reverberation times. Time weighted averages (TWA), noise percentage doses, and peak levels were also collected. The mean Leq for all band directors was 90.5 dBA. The total accumulated noise percentage dose for all band directors was 77.6% of the maximum allowable daily noise dose under the OSHA standard. The total calculated TWA for all band directors was 88.2% of the maximum allowable daily noise dose under the OSHA standard. The total accumulated noise percentage dose for all band directors was 152.1% of the maximum allowable daily noise dose under the NIOSH standards, and the total calculated TWA for all band directors was 93dBA of the maximum allowable daily noise dose under the NIOSH standard. Multiple regression analysis revealed that the room volume, the level of acoustical treatment and the mean room reverberation time predicted 80% of the variance in sound pressure levels in this study.
Examining INM Accuracy Using Empirical Sound Monitoring and Radar Data
NASA Technical Reports Server (NTRS)
Miller, Nicholas P.; Anderson, Grant S.; Horonjeff, Richard D.; Kimura, Sebastian; Miller, Jonathan S.; Senzig, David A.; Thompson, Richard H.; Shepherd, Kevin P. (Technical Monitor)
2000-01-01
Aircraft noise measurements were made using noise monitoring systems at Denver International and Minneapolis St. Paul Airports. Measured sound exposure levels for a large number of operations of a wide range of aircraft types were compared with predictions using the FAA's Integrated Noise Model. In general it was observed that measured levels exceeded the predicted levels by a significant margin. These differences varied according to the type of aircraft and also depended on the distance from the aircraft. Many of the assumptions which affect the predicted sound levels were examined but none were able to fully explain the observed differences.
ERIC Educational Resources Information Center
Faes, Jolien; Gillis, Joris; Gillis, Steven
2017-01-01
The frequency of occurrence of words and sounds has a pervasive influence on typically developing children's language acquisition. For instance, highly frequent words appear earliest in a child's lexicon, and highly frequent phonemes are produced more accurately. This study evaluates (a) whether word frequency influences word accuracy and (b)…
Evaluating effects of vegetation on the acoustical environment by physical scale-modeling
Richard H. Lyon; Cristopher N. Blair; Richard G. DeJong
1977-01-01
It is generally assumed that vegetation is beneficial acoustically, as well as esthetically, in that it may act as a shield to reduce highway noise impact on a community as in a sound absorber to reduce reverberant noise levels in city streets. Contradictory evidence exists, however, that noise may be increased because of vegetation. We performed field studies and...
Khajenasiri, Farahnaz; Zamanian, Alireza; Zamanian, Zahra
2016-03-01
Sound is among the significant environmental factors for people's health, and it has an important role in both physical and psychological injuries, and it also affects individuals' performance and productivity. The aim of this study was to determine the effect of exposure to high noise levels on the performance and rate of error in manual activities. This was an interventional study conducted on 50 students at Shiraz University of Medical Sciences (25 males and 25 females) in which each person was considered as its own control to assess the effect of noise on her or his performance at the sound levels of 70, 90, and 110 dB by using two factors of physical features and the creation of different conditions of sound source as well as applying the Two-Arm coordination Test. The data were analyzed using SPSS version 16. Repeated measurements were used to compare the length of performance as well as the errors measured in the test. Based on the results, we found a direct and significant association between the levels of sound and the length of performance. Moreover, the participant's performance was significantly different for different sound levels (at 110 dB as opposed to 70 and 90 dB, p < 0.05 and p < 0.001, respectively). This study found that a sound level of 110 dB had an important effect on the individuals' performances, i.e., the performances were decreased.
Audio spectrum and sound pressure levels vary between pulse oximeters.
Chandra, Deven; Tessler, Michael J; Usher, John
2006-01-01
The variable-pitch pulse oximeter is an important intraoperative patient monitor. Our ability to hear its auditory signal depends on its acoustical properties and our hearing. This study quantitatively describes the audio spectrum and sound pressure levels of the monitoring tones produced by five variable-pitch pulse oximeters. We compared the Datex-Ohmeda Capnomac Ultima, Hewlett-Packard M1166A, Datex-Engstrom AS/3, Ohmeda Biox 3700, and Datex-Ohmeda 3800 oximeters. Three machines of each of the five models were assessed for sound pressure levels (using a precision sound level meter) and audio spectrum (using a hanning windowed fast Fourier trans-form of three beats at saturations of 99%, 90%, and 85%). The widest range of sound pressure levels was produced by the Hewlett-Packard M1166A (46.5 +/- 1.74 dB to 76.9 +/- 2.77 dB). The loudest model was the Datex-Engstrom AS/3 (89.2 +/- 5.36 dB). Three oximeters, when set to the lower ranges of their volume settings, were indistinguishable from background operating room noise. Each model produced sounds with different audio spectra. Although each model produced a fundamental tone with multiple harmonic overtones, the number of harmonics varied with each model; from three harmonic tones on the Hewlett-Packard M1166A, to 12 on the Ohmeda Biox 3700. There were variations between models, and individual machines of the same model with respect to the fundamental tone associated with a given saturation. There is considerable variance in the sound pressure and audio spectrum of commercially-available pulse oximeters. Further studies are warranted in order to establish standards.
Canale, Andrea; Dalmasso, Giulia; Dagna, Federico; Lacilla, Michelangelo; Montuschi, Carla; Rosa, Rosalba Di; Albera, Roberto
2016-08-01
To determine whether speech recognition scores (SRS) differ between adults with long-term auditory deprivation in the implanted ear and adults who received cochlear implant (CI) in the nonsound-deprived ear, either for hearing aid-assisted or due to rapidly deteriorating hearing loss. Retrospective study. Speech recognition scores at evaluations (3 and 14 months postimplantation) conducted with CI alone at 60-dB sound pressure level intensity were compared in 15 patients (4 with bilateral severe hearing loss; 11 with asymmetric hearing loss, 7 of which had contralateral hearing aid), all with long-term auditory deprivation (mean duration 16.9 years) (group A), and in 15 other patients with postlingual hearing loss (10 symmetric, 5 asymmetric with bimodal stimulation) (controls, group B). Comparison of mean percentage of correctly recognized words on speech audiometry at 3 and 14 months showed improvement within each group (P < 0.05). Between-group comparison showed no significant difference at 3 (P = 0.17) or 14 months (P = 0.46). Comparison of SRSs in group A (bimodal stimulation [n = 7] and binaural sound deprivation [n = 4]) versus group B showed no significant differences at 3 (bimodal stimulation P = 0.16; binaural sound deprivation P = 0.19) or 14 months (bimodal stimulation P = 0.14; binaural sound deprivation P = 0.82). Speech recognition scores in monaural and binaural sound-deprived ears did not significantly differ from ears with unilateral cochlear implantation in nonsound-deprived ears when tested with CI alone. Improvement in the implanted worse ear indicates that it could be a potential candidate ear for cochlear implantation even when sound deprived. 4. Laryngoscope, 126:1905-1910, 2016. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.
Uncovering Spatial Variation in Acoustic Environments Using Sound Mapping.
Job, Jacob R; Myers, Kyle; Naghshineh, Koorosh; Gill, Sharon A
2016-01-01
Animals select and use habitats based on environmental features relevant to their ecology and behavior. For animals that use acoustic communication, the sound environment itself may be a critical feature, yet acoustic characteristics are not commonly measured when describing habitats and as a result, how habitats vary acoustically over space and time is poorly known. Such considerations are timely, given worldwide increases in anthropogenic noise combined with rapidly accumulating evidence that noise hampers the ability of animals to detect and interpret natural sounds. Here, we used microphone arrays to record the sound environment in three terrestrial habitats (forest, prairie, and urban) under ambient conditions and during experimental noise introductions. We mapped sound pressure levels (SPLs) over spatial scales relevant to diverse taxa to explore spatial variation in acoustic habitats and to evaluate the number of microphones needed within arrays to capture this variation under both ambient and noisy conditions. Even at small spatial scales and over relatively short time spans, SPLs varied considerably, especially in forest and urban habitats, suggesting that quantifying and mapping acoustic features could improve habitat descriptions. Subset maps based on input from 4, 8, 12 and 16 microphones differed slightly (< 2 dBA/pixel) from those based on full arrays of 24 microphones under ambient conditions across habitats. Map differences were more pronounced with noise introductions, particularly in forests; maps made from only 4-microphones differed more (> 4 dBA/pixel) from full maps than the remaining subset maps, but maps with input from eight microphones resulted in smaller differences. Thus, acoustic environments varied over small spatial scales and variation could be mapped with input from 4-8 microphones. Mapping sound in different environments will improve understanding of acoustic environments and allow us to explore the influence of spatial variation in sound on animal ecology and behavior.
Development of a Novel Noise Delivery System for JP-8 Ototoxicity Studies
2010-03-01
kHz. The authors indicated that at the time of the article they were not aware of any other studies that investigated simultaneous exposure to...Sound Study.” 4.4 The audiology sound program will be loaded which allows creation of the correct sound levels. 5.0 CREATING SOUND AND COLLECTING
Perceptual constancy in auditory perception of distance to railway tracks.
De Coensel, Bert; Nilsson, Mats E; Berglund, Birgitta; Brown, A L
2013-07-01
Distance to a sound source can be accurately estimated solely from auditory information. With a sound source such as a train that is passing by at a relatively large distance, the most important auditory information for the listener for estimating its distance consists of the intensity of the sound, spectral changes in the sound caused by air absorption, and the motion-induced rate of change of intensity. However, these cues are relative because prior information/experience of the sound source-its source power, its spectrum and the typical speed at which it moves-is required for such distance estimates. This paper describes two listening experiments that allow investigation of further prior contextual information taken into account by listeners-viz., whether they are indoors or outdoors. Asked to estimate the distance to the track of a railway, it is shown that listeners assessing sounds heard inside the dwelling based their distance estimates on the expected train passby sound level outdoors rather than on the passby sound level actually experienced indoors. This form of perceptual constancy may have consequences for the assessment of annoyance caused by railway noise.
Keefe, Douglas H.; Schairer, Kim S.
2011-01-01
An insert ear-canal probe including sound source and microphone can deliver a calibrated sound power level to the ear. The aural power absorbed is proportional to the product of mean-squared forward pressure, ear-canal area, and absorbance, in which the sound field is represented using forward (reverse) waves traveling toward (away from) the eardrum. Forward pressure is composed of incident pressure and its multiple internal reflections between eardrum and probe. Based on a database of measurements in normal-hearing adults from 0.22 to 8 kHz, the transfer-function level of forward relative to incident pressure is boosted below 0.7 kHz and within 4 dB above. The level of forward relative to total pressure is maximal close to 4 kHz with wide variability across ears. A spectrally flat incident-pressure level across frequency produces a nearly flat absorbed power level, in contrast to 19 dB changes in pressure level. Calibrating an ear-canal sound source based on absorbed power may be useful in audiological and research applications. Specifying the tip-to-tail level difference of the suppression tuning curve of stimulus frequency otoacoustic emissions in terms of absorbed power reveals increased cochlear gain at 8 kHz relative to the level difference measured using total pressure. PMID:21361437
Chen, Xuhai; Yang, Jianfeng; Gan, Shuzhen; Yang, Yufang
2012-01-01
Although its role is frequently stressed in acoustic profile for vocal emotion, sound intensity is frequently regarded as a control parameter in neurocognitive studies of vocal emotion, leaving its role and neural underpinnings unclear. To investigate these issues, we asked participants to rate the angry level of neutral and angry prosodies before and after sound intensity modification in Experiment 1, and recorded electroencephalogram (EEG) for mismatching emotional prosodies with and without sound intensity modification and for matching emotional prosodies while participants performed emotional feature or sound intensity congruity judgment in Experiment 2. It was found that sound intensity modification had significant effect on the rating of angry level for angry prosodies, but not for neutral ones. Moreover, mismatching emotional prosodies, relative to matching ones, induced enhanced N2/P3 complex and theta band synchronization irrespective of sound intensity modification and task demands. However, mismatching emotional prosodies with reduced sound intensity showed prolonged peak latency and decreased amplitude in N2/P3 complex and smaller theta band synchronization. These findings suggest that though it cannot categorically affect emotionality conveyed in emotional prosodies, sound intensity contributes to emotional significance quantitatively, implying that sound intensity should not simply be taken as a control parameter and its unique role needs to be specified in vocal emotion studies.